47 CFR 90.259 - Assignment and use of frequencies in the bands 216-220 MHz and 1427-1432 MHz.
Code of Federal Regulations, 2010 CFR
2010-10-01
... assignments will be made after January 1, 2002. (4) In the 217-220 MHz band, the maximum transmitter output... operations will not be authorized. The area of normal day-to-day operations will be described in the... will be assigned with a 6.25 kHz, 12.5 kHz, 25 kHz or 50 kHz channel bandwidth. Frequencies may be...
Code of Federal Regulations, 2014 CFR
2014-10-01
...) LORAN-C is a long range navigation system which operates in the 90-110 kHz band. (2) Radiobeacon... station. Radiobeacons operate in the bands 190-285 kHz; 325-435 kHz; 510-525 kHz; and 525-535 kHz. Radiobeacons may be authorized, primarily for off-shore use, in the band 525-535 kHz on a non-interference...
Ziylan-Yavas, Asu; Ince, Nilsun H
2018-01-01
The study is about the assessment of single and multi-frequency operations for the overall degradation of a widely consumed analgesic pharmaceutical-ibuprofen (IBP). The selected frequencies were in the range of 20-1130kHz emissions coming from probes, baths and piezo-electric transducers attached to plate-type devices. Multi-frequency operations were applied either simultaneously as "duals", or sequentially at fixed time intervals; and the total reaction time in all operations was 30-min. The work also covers evaluation of the effect of zero-valent iron (ZVI) on the efficiency of the degradation process and the performance of the reaction systems. It was found that low-frequency probe type devices especially at 20kHz were ineffective when applied singly and without ZVI, and relatively more effective in combined-frequency operations in the presence of ZVI. The power efficiencies of the reactors and/or reaction systems showed that 20-kHz probe was considerably more energy intensive than all others, and was therefore not used in multi-frequency operations. The most efficient reactor in terms of power consumption was the bath (200kHz), which however provided insufficient mineralization of the test chemical. The highest percentage of TOC decay (37%) was obtained in a dual-frequency operation (40/572kHz) with ZVI, in which the energy consumption was neither low nor exceptionally too high. A sequential operation (40+200kHz) in that respect was more efficient, because it required much less energy for a similar TOC decay performance (30%). In general, the degradation of IBP increased with increased power consumption, which in turn reduced the sonochemical yield. The study also showed that advanced Fenton reactions with ZVI were faster in the presence of ultrasound, and the metal was very effective in improving the performance of low-frequency operations. Copyright © 2017 Elsevier B.V. All rights reserved.
47 CFR 15.33 - Frequency range of radiated measurements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... kHz, up to at least the frequency shown in this paragraph: (1) If the intentional radiator operates... level of radiated emissions within the frequency range 9 kHz to 30 MHz, such as a CB receiver or a... used in the device, without going below 9 kHz (25 MHz for CB receivers), up to the frequency shown in...
47 CFR 15.33 - Frequency range of radiated measurements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... kHz, up to at least the frequency shown in this paragraph: (1) If the intentional radiator operates... level of radiated emissions within the frequency range 9 kHz to 30 MHz, such as a CB receiver or a... used in the device, without going below 9 kHz (25 MHz for CB receivers), up to the frequency shown in...
47 CFR 15.33 - Frequency range of radiated measurements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... kHz, up to at least the frequency shown in this paragraph: (1) If the intentional radiator operates... level of radiated emissions within the frequency range 9 kHz to 30 MHz, such as a CB receiver or a... used in the device, without going below 9 kHz (25 MHz for CB receivers), up to the frequency shown in...
47 CFR 15.33 - Frequency range of radiated measurements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... kHz, up to at least the frequency shown in this paragraph: (1) If the intentional radiator operates... level of radiated emissions within the frequency range 9 kHz to 30 MHz, such as a CB receiver or a... used in the device, without going below 9 kHz (25 MHz for CB receivers), up to the frequency shown in...
47 CFR 15.219 - Operation in the band 510-1705 kHz.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 1 2014-10-01 2014-10-01 false Operation in the band 510-1705 kHz. 15.219... kHz. (a) The total input power to the final radio frequency stage (exclusive of filament or heater... ground lead (if used) shall not exceed 3 meters. (c) All emissions below 510 kHz or above 1705 kHz shall...
47 CFR 15.219 - Operation in the band 510-1705 kHz.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Operation in the band 510-1705 kHz. 15.219... kHz. (a) The total input power to the final radio frequency stage (exclusive of filament or heater... ground lead (if used) shall not exceed 3 meters. (c) All emissions below 510 kHz or above 1705 kHz shall...
47 CFR 15.219 - Operation in the band 510-1705 kHz.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Operation in the band 510-1705 kHz. 15.219... kHz. (a) The total input power to the final radio frequency stage (exclusive of filament or heater... ground lead (if used) shall not exceed 3 meters. (c) All emissions below 510 kHz or above 1705 kHz shall...
47 CFR 15.219 - Operation in the band 510-1705 kHz.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Operation in the band 510-1705 kHz. 15.219... kHz. (a) The total input power to the final radio frequency stage (exclusive of filament or heater... ground lead (if used) shall not exceed 3 meters. (c) All emissions below 510 kHz or above 1705 kHz shall...
47 CFR 15.219 - Operation in the band 510-1705 kHz.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 1 2013-10-01 2013-10-01 false Operation in the band 510-1705 kHz. 15.219... kHz. (a) The total input power to the final radio frequency stage (exclusive of filament or heater... ground lead (if used) shall not exceed 3 meters. (c) All emissions below 510 kHz or above 1705 kHz shall...
47 CFR 90.173 - Policies governing the assignment of frequencies.
Code of Federal Regulations, 2013 CFR
2013-10-01
... for stations in the 150-174 MHz and 421-512 MHz bands for operation on frequencies 15 kHz or less... frequencies that were available prior to August 18, 1995 will be granted with channel bandwidths of 25 kHz or... 12.5 kHz or less (i.e., in the Public Safety Pool, frequencies subject to §§ 90.20 (d)(27) and (d)(44...
47 CFR 90.173 - Policies governing the assignment of frequencies.
Code of Federal Regulations, 2012 CFR
2012-10-01
... for stations in the 150-174 MHz and 421-512 MHz bands for operation on frequencies 15 kHz or less... frequencies that were available prior to August 18, 1995 will be granted with channel bandwidths of 25 kHz or... 12.5 kHz or less (i.e., in the Public Safety Pool, frequencies subject to §§ 90.20 (d)(27) and (d)(44...
47 CFR 90.173 - Policies governing the assignment of frequencies.
Code of Federal Regulations, 2014 CFR
2014-10-01
... for stations in the 150-174 MHz and 421-512 MHz bands for operation on frequencies 15 kHz or less... frequencies that were available prior to August 18, 1995 will be granted with channel bandwidths of 25 kHz or... 12.5 kHz or less (i.e., in the Public Safety Pool, frequencies subject to §§ 90.20 (d)(27) and (d)(44...
47 CFR 90.173 - Policies governing the assignment of frequencies.
Code of Federal Regulations, 2011 CFR
2011-10-01
... for stations in the 150-174 MHz and 421-512 MHz bands for operation on frequencies 15 kHz or less... frequencies that were available prior to August 18, 1995 will be granted with channel bandwidths of 25 kHz or... 12.5 kHz or less (i.e., in the Public Safety Pool, frequencies subject to §§ 90.20 (d)(27) and (d)(44...
47 CFR 90.173 - Policies governing the assignment of frequencies.
Code of Federal Regulations, 2010 CFR
2010-10-01
... for stations in the 150-174 MHz and 421-512 MHz bands for operation on frequencies 15 kHz or less... frequencies that were available prior to August 18, 1995 will be granted with channel bandwidths of 25 kHz or... 12.5 kHz or less (i.e., in the Public Safety Pool, frequencies subject to §§ 90.20 (d)(27) and (d)(44...
47 CFR 90.214 - Transient frequency behavior.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Transient frequency behavior. 90.214 Section 90... PRIVATE LAND MOBILE RADIO SERVICES General Technical Standards § 90.214 Transient frequency behavior... Behavior for Equipment Designed to Operate on 25 kHz Channels t1 4 ±25.0 kHz 5.0 ms 10.0 ms t2 ±12.5 kHz 20...
47 CFR 90.214 - Transient frequency behavior.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 5 2013-10-01 2013-10-01 false Transient frequency behavior. 90.214 Section 90... PRIVATE LAND MOBILE RADIO SERVICES General Technical Standards § 90.214 Transient frequency behavior... Behavior for Equipment Designed to Operate on 25 kHz Channels t1 4 ±25.0 kHz 5.0 ms 10.0 ms t2 ±12.5 kHz 20...
47 CFR 90.214 - Transient frequency behavior.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false Transient frequency behavior. 90.214 Section 90... PRIVATE LAND MOBILE RADIO SERVICES General Technical Standards § 90.214 Transient frequency behavior... Behavior for Equipment Designed to Operate on 25 kHz Channels t1 4 ±25.0 kHz 5.0 ms 10.0 ms t2 ±12.5 kHz 20...
47 CFR 90.214 - Transient frequency behavior.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false Transient frequency behavior. 90.214 Section 90... PRIVATE LAND MOBILE RADIO SERVICES General Technical Standards § 90.214 Transient frequency behavior... Behavior for Equipment Designed to Operate on 25 kHz Channels t1 4 ±25.0 kHz 5.0 ms 10.0 ms t2 ±12.5 kHz 20...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-28
...) Over the horizon high frequency sky-wave (ionosphere) radar; (xvi) Radar that detects a moving object... any dimension equal to or less than one quarter (\\1/4\\) wavelength of the highest operating frequency... capability; (B) Operating frequency less than 20 kHz; (C) Bandwidth greater than 10 kHz; or (D) Capable of...
Frequency stability of a dual wavelength quantum cascade laser.
Sergachev, Ilia; Maulini, Richard; Gresch, Tobias; Blaser, Stéphane; Bismuto, Alfredo; Müller, Antoine; Bidaux, Yves; Südmeyer, Thomas; Schilt, Stéphane
2017-05-15
We characterized the dual wavelength operation of a distributed Bragg reflector (DBR) quantum cascade laser (QCL) operating at 4.5 μm using two independent optical frequency discriminators. The QCL emits up to 150 mW fairly evenly distributed between two adjacent Fabry-Perot modes separated by ≈11.6 GHz. We show a strong correlation between the instantaneous optical frequencies of the two lasing modes, characterized by a Pearson correlation coefficient of 0.96. As a result, we stabilized one laser mode of the QCL to a N 2 O transition using a side-of-fringe locking technique, reducing its linewidth by a factor 6.2, from 406 kHz in free-running operation down to 65 kHz (at 1-ms observation time), and observed a simultaneous reduction of the frequency fluctuations of the second mode by a similar amount, resulting in a linewidth narrowing by a factor 5.4, from 380 kHz to 70 kHz. This proof-of-principle demonstration was performed with a standard DBR QCL that was not deliberately designed for dual-mode operation. These promising results open the door to the fabrication of more flexible dual-mode QCLs with the use of specifically designed gratings in the future.
Upgrade of JET AE Active Diagnostic for Low Frequency Eigenmodes Detection
NASA Astrophysics Data System (ADS)
Puglia, P.; Blanchard, P.; Testa, D.; Fasoli, A.; Aslanyan, V.; Porkolab, M.; Woskov, P.; Ruchko, L.; Galvao, R.; Pires de Sa, W.; Dos Reis, A.; Sharapov, S.; Dowson, S.,; Sheikh, H.; Blackman, T.; Jones, G.; Dorling, S.; Figueiredo, J.; Perez von Thun, C.; JET Collaboration
2017-10-01
The upgrade of the Toroidal Alfvén Eigenmode Active Antenna diagnostic at JET was commissioned last year. The new amplifiers have an operational frequency range limited to bands within 10-1000 kHz by a choice of filters. In the last campaigns the AE excitation system was operated on the Alfvénic range of frequencies (f > 80 kHz). For the next campaigns we are proposing operation on the frequency range of 25-50 kHz to excite eigenmodes on the Alfvén-acoustic range (GAMs, BAEs and Alfvén Cascades). The next JET campaigns will involve use of deuterium, tritium and hydrogen, giving a wide range of parameters for the modes to be investigated. Details of the system modifications for operation in this new frequency range and experimental scenarios will be discussed. This work has been carried out within the framework of the EUROfusion Consortium No 633053. Support was provided by the US DOE, FAPESP Project 2011/50773-0, by the Swiss NSF, and also the RCUK Energy Programme [Grant Number EP/P012450/1].
47 CFR 76.612 - Cable television frequency separation standards.
Code of Federal Regulations, 2010 CFR
2010-10-01
... frequency separation standards. All cable television systems which operate in the frequency bands 108-137... kHz bandwidth in any 160 microsecond period must operate at frequencies offset from certain frequencies which may be used by aeronautical radio services operated by Commission licensees or by the United...
47 CFR 87.133 - Frequency stability.
Code of Federal Regulations, 2011 CFR
2011-10-01
... operating in U.S. controlled airspace with 8.33 kHz channel spacing (except equipment being tested by... Tolerance 2 (1) Band-9 to 535 kHz: Aeronautical stations 100 100 Aircraft stations 200 100 Survival craft stations on 500 kHz 5,000 20 Hz 3 Radionavigation stations 100 100 (2) Band-1605 to 4000 kHz: Aeronautical...
47 CFR 87.133 - Frequency stability.
Code of Federal Regulations, 2012 CFR
2012-10-01
... operating in U.S. controlled airspace with 8.33 kHz channel spacing (except equipment being tested by... Tolerance 2 (1) Band-9 to 535 kHz: Aeronautical stations 100 100 Aircraft stations 200 100 Survival craft stations on 500 kHz 5,000 20 Hz 3 Radionavigation stations 100 100 (2) Band-1605 to 4000 kHz: Aeronautical...
47 CFR 87.133 - Frequency stability.
Code of Federal Regulations, 2013 CFR
2013-10-01
... operating in U.S. controlled airspace with 8.33 kHz channel spacing (except equipment being tested by... Tolerance 2 (1) Band-9 to 535 kHz: Aeronautical stations 100 100 Aircraft stations 200 100 Survival craft stations on 500 kHz 5,000 20 Hz 3 Radionavigation stations 100 100 (2) Band-1605 to 4000 kHz: Aeronautical...
47 CFR 15.247 - Operation within the bands 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz.
Code of Federal Regulations, 2011 CFR
2011-10-01
... channel carrier frequencies separated by a minimum of 25 kHz or the 20 dB bandwidth of the hopping channel... have hopping channel carrier frequencies that are separated by 25 kHz or two-thirds of the 20 dB...: if the 20 dB bandwidth of the hopping channel is less than 250 kHz, the system shall use at least 50...
47 CFR 15.247 - Operation within the bands 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz.
Code of Federal Regulations, 2014 CFR
2014-10-01
... channel carrier frequencies separated by a minimum of 25 kHz or the 20 dB bandwidth of the hopping channel... have hopping channel carrier frequencies that are separated by 25 kHz or two-thirds of the 20 dB...: if the 20 dB bandwidth of the hopping channel is less than 250 kHz, the system shall use at least 50...
47 CFR 15.247 - Operation within the bands 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz.
Code of Federal Regulations, 2010 CFR
2010-10-01
... channel carrier frequencies separated by a minimum of 25 kHz or the 20 dB bandwidth of the hopping channel... have hopping channel carrier frequencies that are separated by 25 kHz or two-thirds of the 20 dB...: if the 20 dB bandwidth of the hopping channel is less than 250 kHz, the system shall use at least 50...
47 CFR 15.247 - Operation within the bands 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz.
Code of Federal Regulations, 2013 CFR
2013-10-01
... channel carrier frequencies separated by a minimum of 25 kHz or the 20 dB bandwidth of the hopping channel... have hopping channel carrier frequencies that are separated by 25 kHz or two-thirds of the 20 dB...: if the 20 dB bandwidth of the hopping channel is less than 250 kHz, the system shall use at least 50...
47 CFR 15.247 - Operation within the bands 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz.
Code of Federal Regulations, 2012 CFR
2012-10-01
... channel carrier frequencies separated by a minimum of 25 kHz or the 20 dB bandwidth of the hopping channel... have hopping channel carrier frequencies that are separated by 25 kHz or two-thirds of the 20 dB...: if the 20 dB bandwidth of the hopping channel is less than 250 kHz, the system shall use at least 50...
High frequency, high power capacitor development
NASA Astrophysics Data System (ADS)
White, C. W.; Hoffman, P. S.
1983-03-01
A program to develop a special high energy density, high power transfer capacitor to operate at frequency of 40 kHz, 600 V rms at 125 A rms plus 600 V dc bias for space operation. The program included material evaluation and selection, a capacitor design was prepared, a thermal analysis performed on the design. Fifty capacitors were manufactured for testing at 10 kHz and 40 kHz for 50 hours at Industrial Electric Heating Co. of Columbus, Ohio. The vacuum endurance test used on environmental chamber and temperature plate furnished by Maxwell. The capacitors were energized with a special power conditioning apparatus developed by Industrial Electric Heating Co. Temperature conditions of the capacitors were monitored by IEHCo test equipment. Successful completion of the vacuum endurance test series confirmed achievement of the main goal of producing a capacitor or reliable operation at high frequency in an environment normally not hospitable to electrical and electronic components. The capacitor developed compared to a typical commercial capacitor at the 40 kHz level represents a decrease in size and weight by a factor of seven.
High frequency, high power capacitor development
NASA Technical Reports Server (NTRS)
White, C. W.; Hoffman, P. S.
1983-01-01
A program to develop a special high energy density, high power transfer capacitor to operate at frequency of 40 kHz, 600 V rms at 125 A rms plus 600 V dc bias for space operation. The program included material evaluation and selection, a capacitor design was prepared, a thermal analysis performed on the design. Fifty capacitors were manufactured for testing at 10 kHz and 40 kHz for 50 hours at Industrial Electric Heating Co. of Columbus, Ohio. The vacuum endurance test used on environmental chamber and temperature plate furnished by Maxwell. The capacitors were energized with a special power conditioning apparatus developed by Industrial Electric Heating Co. Temperature conditions of the capacitors were monitored by IEHCo test equipment. Successful completion of the vacuum endurance test series confirmed achievement of the main goal of producing a capacitor or reliable operation at high frequency in an environment normally not hospitable to electrical and electronic components. The capacitor developed compared to a typical commercial capacitor at the 40 kHz level represents a decrease in size and weight by a factor of seven.
47 CFR 97.301 - Authorized frequency bands.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., or who holds a Class 1 IARP license: Wavelength band MF ITU region 1 kHz ITU region 2 kHz ITU region 3 kHz Sharing requirements see § 97.303(paragraph) 160 m 1810-1850 1800-2000 1800-2000 (a), (c), (g... who has been granted an operator license of Advanced Class: Wavelength band MF ITU region 1 kHz ITU...
47 CFR 74.464 - Frequency tolerance.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 30 kHz, the licensee of a remote pickup broadcast station or system shall maintain the operating... chapter. For all other operations, the licensee of a remote pickup broadcast station or system shall maintain the operating frequency of each station in accordance with the following: Frequency range...
47 CFR 74.464 - Frequency tolerance.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 30 kHz, the licensee of a remote pickup broadcast station or system shall maintain the operating... chapter. For all other operations, the licensee of a remote pickup broadcast station or system shall maintain the operating frequency of each station in accordance with the following: Frequency range...
Signal Analysis Van Hardware Operation General Description. Volume 1.
1981-12-01
safety and the prevention of equip- ment malfunction in high RF energy fields, a shielded enclosure was installed within the semitrailer shell. This...Clock B can be prgram -selected to operate at one of seven clock rates, one of five crystal-controlled frequencies (1 MHz, 100 kHz, 10 kHz, or 100 Hz
Operating principles of an electrothermal vibrometer for optical switching applications
NASA Astrophysics Data System (ADS)
Pai, Min-fan; Tien, Norman C.
1999-09-01
A compact polysilicon surface-micromachined microactuator designed for optical switching applications is described. This actuator is fabricated using the foundry MUMPs process provided by Cronos Integrated Microsystems Inc. Actuated electrothermally, the microactuator allows fast switching speeds and can be operated with a low voltage square-wave signal. The design, operation mechanisms for this long-range and high frequency thermal actuation are described. A vertical micromirror integrated with this actuator can be operated with a 10.5 V, 20 kHz 15% duty-cycle pulse signal, achieving a lateral moving speed higher than 15.6 mm/sec. The optical switch has been operated to frequencies as high as 30 kHz.
Objective measurement of subjective tinnitus using the acoustic change complex.
Han, Ji-Hye; Won, Joong Yeon; Hong, Sung Kwang; Kim, Ja Hee; Kim, Eun Soo; Kim, Hyung-Jong; Lee, Hyo-Jeong
2017-01-01
At present, there is no objective method for diagnosing subjective sensorineural tinnitus. Recently, the acoustic change complex (ACC) has been used to evaluate neural detection of sounds. Thus, the present study aimed to examine whether the ACC can reflect cortical detection and discrimination of sounds matched with tinnitus frequencies. We hypothesized that the ACC to change stimuli matched with tinnitus frequencies would be decreased in tinnitus patients because the tinnitus interferes with the perception of acoustic changes. To test the hypothesis, 96 ears of normal-hearing (NH) tinnitus patients and controls were tested. Among the tinnitus patients, 33 ears with a tinnitus frequency of 8 kHz constituted the tinnitus group, and the remaining 63 ears with no experience of tinnitus were allocated to the control group. For the 4 kHz non-tinnitus matched frequency, a subset of tinnitus (n = 17) and NH (n = 47) subjects was tested. The acoustic stimuli were pure tones with a total duration of 500 ms consisting of a 1 kHz tone in the first 250 ms and a second tone of either 8 kHz or 4 kHz in the latter 250 ms. The normalized amplitude of the ACC (naACC) was calculated separately for the amplitude of the N1'-P2' complex evoked by an 8 kHz or 4 kHz change stimulus and for the amplitude of the N1-P2 complex elicited by the initial 1 kHz background stimulus. Our results showed that the naACC to an 8 kHz stimulus in the tinnitus group was significantly smaller than those to 4 kHz and 8 kHz in normal controls. Additionally, in the tinnitus group, the naACC to 4 kHz was greater compared to 8 kHz. The receiver operating characteristic (ROC) curve analysis conducted for naACC to 8 kHz at UCL revealed a fair degree of diagnostic efficacy. Overall, our results indicated that the ACC to a change stimulus matched with the tinnitus frequency can provide an objective measure of frequency-specific tinnitus.
Objective measurement of subjective tinnitus using the acoustic change complex
Han, Ji-Hye; Won, Joong Yeon; Hong, Sung Kwang; Kim, Ja Hee; Kim, Eun Soo; Kim, Hyung-Jong
2017-01-01
At present, there is no objective method for diagnosing subjective sensorineural tinnitus. Recently, the acoustic change complex (ACC) has been used to evaluate neural detection of sounds. Thus, the present study aimed to examine whether the ACC can reflect cortical detection and discrimination of sounds matched with tinnitus frequencies. We hypothesized that the ACC to change stimuli matched with tinnitus frequencies would be decreased in tinnitus patients because the tinnitus interferes with the perception of acoustic changes. To test the hypothesis, 96 ears of normal-hearing (NH) tinnitus patients and controls were tested. Among the tinnitus patients, 33 ears with a tinnitus frequency of 8 kHz constituted the tinnitus group, and the remaining 63 ears with no experience of tinnitus were allocated to the control group. For the 4 kHz non-tinnitus matched frequency, a subset of tinnitus (n = 17) and NH (n = 47) subjects was tested. The acoustic stimuli were pure tones with a total duration of 500 ms consisting of a 1 kHz tone in the first 250 ms and a second tone of either 8 kHz or 4 kHz in the latter 250 ms. The normalized amplitude of the ACC (naACC) was calculated separately for the amplitude of the N1’-P2’ complex evoked by an 8 kHz or 4 kHz change stimulus and for the amplitude of the N1-P2 complex elicited by the initial 1 kHz background stimulus. Our results showed that the naACC to an 8 kHz stimulus in the tinnitus group was significantly smaller than those to 4 kHz and 8 kHz in normal controls. Additionally, in the tinnitus group, the naACC to 4 kHz was greater compared to 8 kHz. The receiver operating characteristic (ROC) curve analysis conducted for naACC to 8 kHz at UCL revealed a fair degree of diagnostic efficacy. Overall, our results indicated that the ACC to a change stimulus matched with the tinnitus frequency can provide an objective measure of frequency-specific tinnitus. PMID:29176873
Broadband Acoustic Environment at a Tidal Energy Site in Puget Sound
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Jinshan; Deng, Zhiqun; Martinez, Jayson J.
2012-04-04
Admiralty Inlet has been selected as a potential tidal energy site. It is located near shipping lanes, is a highly variable acoustic environment, and is frequented by the endangered southern resident killer whale (SRKW). Resolving environmental impacts is the first step to receiving approval to deploy tidal turbines. Several monitoring technologies are being considered to determine the presence of SRKW near the turbines. Broadband noise level measurements are critical for determining design and operational specifications of these technologies. Acoustic environment data at the proposed site was acquired at different depths using a cabled vertical line array from three different cruisesmore » during high tidal period in February, May, and June 2011. The ambient noise level decreases approximately 25 dB re 1 μPa per octave from frequency ranges of 1 kHz to 70 kHz, and increases approximately 20 dB re 1 μPa per octave for the frequency from 70 kHz to 200 kHz. The difference of noise pressure levels in different months varies from 10 to 30 dB re 1 μPa for the frequency range below 70 kHz. Commercial shipping and ferry vessel traffic were found to be the most significant contributors to sound pressure levels for the frequency range from 100 Hz to 70 kHz, and the variation could be as high as 30 dB re 1 μPa. These noise level measurements provide the basic information for designing and evaluating both active and passive monitoring systems proposed for deploying and operating for tidal power generation alert system.« less
A dumbbell-shaped hybrid magnetometer operating in DC-10 kHz
NASA Astrophysics Data System (ADS)
Shi, Hongyu; Wang, Yanzhang; Chen, Siyu; Lin, Jun
2017-12-01
This study is motivated by the need to design a hybrid magnetometer operating in a wide-frequency band from DC to 10 kHz. To achieve this objective, a residence times difference fluxgate magnetometer (RTDFM) and an induction magnetometer (IM) have been integrated into a compact form. The hybrid magnetometer has a dumbbell-shaped structure in which the RTDFM transducer is partially inserted into the tube cores of the IM. Thus, the sensitivity of the RTDFM is significantly improved due to the flux amplification. The optimal structure, which has maximum sensitivity enhancement, was obtained through FEM analysis. To validate the theoretical analysis, the optimal hybrid magnetometer was manufactured, and its performance was evaluated. The device has a sensitivity of 45 mV/nT at 1 kHz in IM mode and 0.38 μs/nT in RTDFM mode, which is approximately 3.45 times as large as that of the single RTDFM structure. Furthermore, to obtain a lower noise performance in the entire frequency band, two operation modes switch at the cross frequency (0.16 Hz) of their noise levels. The noise level is 30 pT/√Hz in RTDFM mode and 0.07 pT/√Hz at 1 kHz in IM mode.
A dumbbell-shaped hybrid magnetometer operating in DC-10 kHz.
Shi, Hongyu; Wang, Yanzhang; Chen, Siyu; Lin, Jun
2017-12-01
This study is motivated by the need to design a hybrid magnetometer operating in a wide-frequency band from DC to 10 kHz. To achieve this objective, a residence times difference fluxgate magnetometer (RTDFM) and an induction magnetometer (IM) have been integrated into a compact form. The hybrid magnetometer has a dumbbell-shaped structure in which the RTDFM transducer is partially inserted into the tube cores of the IM. Thus, the sensitivity of the RTDFM is significantly improved due to the flux amplification. The optimal structure, which has maximum sensitivity enhancement, was obtained through FEM analysis. To validate the theoretical analysis, the optimal hybrid magnetometer was manufactured, and its performance was evaluated. The device has a sensitivity of 45 mV/nT at 1 kHz in IM mode and 0.38 μs/nT in RTDFM mode, which is approximately 3.45 times as large as that of the single RTDFM structure. Furthermore, to obtain a lower noise performance in the entire frequency band, two operation modes switch at the cross frequency (0.16 Hz) of their noise levels. The noise level is 30 pT/√Hz in RTDFM mode and 0.07 pT/√Hz at 1 kHz in IM mode.
47 CFR 15.239 - Operation in the band 88-108 MHz.
Code of Federal Regulations, 2012 CFR
2012-10-01
... on the operating frequency. The 200 kHz band shall lie wholly within the frequency range of 88-108... employing an average detector. The provisions in § 15.35 for limiting peak emissions apply. (c) The field...
47 CFR 15.239 - Operation in the band 88-108 MHz.
Code of Federal Regulations, 2011 CFR
2011-10-01
... on the operating frequency. The 200 kHz band shall lie wholly within the frequency range of 88-108... employing an average detector. The provisions in § 15.35 for limiting peak emissions apply. (c) The field...
47 CFR 15.239 - Operation in the band 88-108 MHz.
Code of Federal Regulations, 2014 CFR
2014-10-01
... on the operating frequency. The 200 kHz band shall lie wholly within the frequency range of 88-108... employing an average detector. The provisions in § 15.35 for limiting peak emissions apply. (c) The field...
47 CFR 15.239 - Operation in the band 88-108 MHz.
Code of Federal Regulations, 2013 CFR
2013-10-01
... on the operating frequency. The 200 kHz band shall lie wholly within the frequency range of 88-108... employing an average detector. The provisions in § 15.35 for limiting peak emissions apply. (c) The field...
47 CFR 15.33 - Frequency range of radiated measurements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... radiator operates at or above 30 GHz: to the fifth harmonic of the highest fundamental frequency or to 200... kHz, up to at least the frequency shown in this paragraph: (1) If the intentional radiator operates below 10 GHz: to the tenth harmonic of the highest fundamental frequency or to 40 GHz, whichever is...
200 Deg C Demonstration Transformer Operates Efficiently at 50 kHz
NASA Technical Reports Server (NTRS)
Niedra, Janis M.; Schwarze, Gene E. (Technical Monitor)
2003-01-01
A compact, high temperature demonstration transformer was constructed, using a moly permalloy powder core and Teflon -insulated copper wire. At 50 kHz and 200 C, this 1:2 ratio transformer is capable of 98 percent efficiency when operating at a specific power of 6.1 kW/kg at 4 kW. This roughly 7 cm diameter transformer has a mass of 0.65 kg. Although Teflon is unstable above 200 C, about the same electrical performance was seen at 250 C. A plot of winding loss versus frequency illustrates the need to control these losses at high frequency.
NASA Astrophysics Data System (ADS)
Nan, Qi; Fan, Chen; Lingwei, Zhang; Xiaoman, Wang; Baoyong, Chi
2013-09-01
A reconfigurable multi-mode direct-conversion transmitter (TX) with integrated frequency synthesizer (FS) is presented. The TX as well as the FS is designed with a flexible architecture and frequency plan, which helps to support all the 433/868/915 MHz ISM band signals, with the reconfigurable bandwidth from 250 kHz to 2 MHz. In order to save power and chip area, only one 1.8 GHz VCO is adopted to cover the whole frequency range. All the operation modes can be regulated in real time by configuring the integrated register-bank through an SPI interface. Implemented in 180 nm CMOS, the FS achieves a frequency coverage of 320-460 MHz and 620-920 MHz. The lowest phase noise can be -107 dBc/Hz at a 100 kHz offset and -126 dBc/Hz at a 1 MHz offset. The transmitter features a + 10.2 dBm peak output power with a +9.5 dBm 1-dB-compression point and 250 kHz/500 kHz/1 MHz/2 MHz reconfigurable signal bandwidth.
Effects of chemical releases by the STS-3 Orbiter on the ionosphere
NASA Technical Reports Server (NTRS)
Pickett, J. S.; Murphy, G. B.; Kurth, W. S.; Goertz, C. K.; Shawhan, S. D.
1983-01-01
The Plasma Diagnostics Package, flown aboard STS-3 as part of the first Shuttle payload (OSS-1), recorded the effects of various chemical releases from the Orbiter. Changes in the plasma environment was observed during flash evaporator system releases, water dumps and maneuvering thruster operations. During flash evaporator operations, broadband Orbiter-generated electrostatic noise was enhanced and plasma density irregularities were observed to increase by 3 to 30 times with a spectrum which rose steeply and peaked below 6 Hz. In the case of water dumps, background electrostatic noise was enhanced at frequencies below about 3 kHz and suppressed at frequencies above 2 kHz. Thruster activity also stimulated electrostatic noise with a spectrum which peaked at approximately 0.5 kHz. In addition, ions with energies up to 1 keV were seen during some thruster events.
47 CFR 90.242 - Travelers' information stations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false Travelers' information stations. 90.242 Section...' information stations. (a) The frequencies 530 through 1700 kHz in 10 kHz increments may be assigned to the Public Safety Pool for the operation of Travelers' Information Stations subject to the following...
47 CFR 90.242 - Travelers' information stations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Travelers' information stations. 90.242 Section...' information stations. (a) The frequencies 530 through 1700 kHz in 10 kHz increments may be assigned to the Public Safety Pool for the operation of Travelers' Information Stations subject to the following...
47 CFR 90.242 - Travelers' information stations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 5 2013-10-01 2013-10-01 false Travelers' information stations. 90.242 Section...' information stations. (a) The frequencies 530 through 1700 kHz in 10 kHz increments may be assigned to the Public Safety Pool for the operation of Travelers' Information Stations subject to the following...
47 CFR 90.242 - Travelers' information stations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false Travelers' information stations. 90.242 Section...' information stations. (a) The frequencies 530 through 1700 kHz in 10 kHz increments may be assigned to the Public Safety Pool for the operation of Travelers' Information Stations subject to the following...
47 CFR 15.207 - Conducted limits.
Code of Federal Regulations, 2010 CFR
2010-10-01
... apply to carrier current systems operating as intentional radiators on frequencies below 30 MHz. In lieu... current system containing their fundamental emission within the frequency band 535-1705 kHz and intended.../50 ohms LISN. (3) Carrier current systems operating below 30 MHz are also subject to the radiated...
Code of Federal Regulations, 2010 CFR
2010-10-01
... ship-to-shore duplex operations with coast stations assigned the frequencies described in § 80.371(b... shore-to-ship simplex operations; or (iv) Duplex operations with coast stations assigned in the band... coast stations for: (i) Supplementary ship-to-shore duplex operations with coast stations assigned the...
Bruel and Kjaer 4944 Microphone Grid Frequency Response Function System Identification
NASA Technical Reports Server (NTRS)
Bennett, Reginald; Lee, Erik
2010-01-01
Br el & Kjaer (B&K) 4944B pressure field microphone was judiciously selected to measure acoustic environments, 400Hz 50kHz, in close proximity of the nozzle during multiple firings of solid propellant rocket motors. It is well known that protective grids can affect the frequency response of microphones. B&K recommends operation of the B&K 4944B without a protective grid when recording measurements above 10 to 15 kHz.
47 CFR 15.107 - Conducted limits.
Code of Federal Regulations, 2010 CFR
2010-10-01
... not apply to carrier current systems operating as unintentional radiators on frequencies below 30 MHz... carrier current systems containing their fundamental emission within the frequency band 535-1705 kHz and... 50 μH/50 ohms LISN. (3) Carrier current systems operating below 30 MHz are also subject to the...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Yong-Jie; Yuan, Qiang-Hua; Li, Fei
2013-11-15
An atmospheric pressure plasma jet is generated by dual sinusoidal wave (50 kHz and 2 MHz). The dual-frequency plasma jet exhibits the advantages of both low frequency and radio frequency plasmas, namely, the long plasma plume and the high electron density. The radio frequency ignition voltage can be reduced significantly by using dual-frequency excitation compared to the conventional radio frequency without the aid of the low frequency excitation source. A larger operating range of α mode discharge can be obtained using dual-frequency excitation which is important to obtain homogeneous and low-temperature plasma. A larger controllable range of the gas temperaturemore » of atmospheric pressure plasma could also be obtained using dual-frequency excitation.« less
Field-Oriented Control Of Induction Motors
NASA Technical Reports Server (NTRS)
Burrows, Linda M.; Roth, Mary Ellen; Zinger, Don S.
1993-01-01
Field-oriented control system provides for feedback control of torque or speed or both. Developed for use with commercial three-phase, 400-Hz, 208-V, 5-hp motor. Systems include resonant power supply operating at 20 kHz. Pulse-population-modulation subsystem selects individual pulses of 20-kHz single-phase waveform as needed to synthesize three waveforms of appropriate lower frequency applied to three phase windings of motor. Electric actuation systems using technology currently being built to peak powers of 70 kW. Amplitude of voltage of effective machine-frequency waveform determined by momentary frequency of pulses, while machine frequency determined by rate of repetition of overall temporal pattern of pulses. System enables independent control of both voltage and frequency.
2004-05-12
Structural Engineering, La Jolla, CA 92093 14. ABSTRACT Tunable optical filters based on a Fabry - Perot element are a critical component in many...wavelength based fiber optic sensor systems. This report compares the performance of two fiber-pigtailed tunable optical filters, the fiber Fabry - Perot (FFP...both filters suggests that they can operate at frequencies up to 20 kHz and possibly as high as 100 kHz. 15. SUBJECT TERMS Tunable Fabry - Perot filters
High-sensitivity operation of single-beam optically pumped magnetometer in a kHz frequency range
Savukov, Igor Mykhaylovich; Kim, Y. J.; Shah, V.; ...
2017-02-02
Here, optically pumped magnetometers (OPM) can be used in various applications, from magnetoencephalography to magnetic resonance imaging and nuclear quadrupole resonance (NQR). OPMs provide high sensitivity and have the significant advantage of non-cryogenic operation. To date, many magnetometers have been demonstrated with sensitivity close to 1 fT, but most devices are not commercialized. Most recently, QuSpin developed a model of OPM that is low cost, high sensitivity, and convenient for users, which operates in a single-beam configuration. Here we developed a theory of single-beam (or parallel two-beam) magnetometers and showed that it is possible to achieve good sensitivity beyond theirmore » usual frequency range by tuning the magnetic field. Experimentally we have tested and optimized a QuSpin OPM for operation in the frequency range from DC to 1.7 kHz, and found that the performance was only slightly inferior despite the expected decrease due to deviation from the spin-exchange relaxation-free regime.« less
High-sensitivity operation of single-beam optically pumped magnetometer in a kHz frequency range
DOE Office of Scientific and Technical Information (OSTI.GOV)
Savukov, Igor Mykhaylovich; Kim, Y. J.; Shah, V.
Here, optically pumped magnetometers (OPM) can be used in various applications, from magnetoencephalography to magnetic resonance imaging and nuclear quadrupole resonance (NQR). OPMs provide high sensitivity and have the significant advantage of non-cryogenic operation. To date, many magnetometers have been demonstrated with sensitivity close to 1 fT, but most devices are not commercialized. Most recently, QuSpin developed a model of OPM that is low cost, high sensitivity, and convenient for users, which operates in a single-beam configuration. Here we developed a theory of single-beam (or parallel two-beam) magnetometers and showed that it is possible to achieve good sensitivity beyond theirmore » usual frequency range by tuning the magnetic field. Experimentally we have tested and optimized a QuSpin OPM for operation in the frequency range from DC to 1.7 kHz, and found that the performance was only slightly inferior despite the expected decrease due to deviation from the spin-exchange relaxation-free regime.« less
Description of a 20 kilohertz power distribution system
NASA Technical Reports Server (NTRS)
Hansen, I. G.
1986-01-01
A single phase, 440 VRMS, 20 kHz power distribution system with a regulated sinusoidal wave form is discussed. A single phase power system minimizes the wiring, sensing, and control complexities required in a multi-sourced redundantly distributed power system. The single phase addresses only the distribution links multiphase lower frequency inputs and outputs accommodation techniques are described. While the 440 V operating potential was initially selected for aircraft operating below 50,000 ft, this potential also appears suitable for space power systems. This voltage choice recognizes a reasonable upper limit for semiconductor ratings, yet will direct synthesis of 220 V, 3 power. A 20 kHz operating frequency was selected to be above the range of audibility, minimize the weight of reactive components, yet allow the construction of single power stages of 25 to 30 kW. The regulated sinusoidal distribution system has several advantages. With a regulated voltage, most ac/dc conversions involve rather simple transformer rectifier applications. A sinusoidal distribution system, when used in conjunction with zero crossing switching, represents a minimal source of EMI. The present state of 20 kHz power technology includes computer controls of voltage and/or frequency, low inductance cable, current limiting circuit protection, bi-directional power flow, and motor/generator operating using standard induction machines. A status update and description of each of these items and their significance is presented.
Description of a 20 Kilohertz power distribution system
NASA Technical Reports Server (NTRS)
Hansen, I. G.
1986-01-01
A single phase, 440 VRMS, 20 kHz power distribution system with a regulated sinusoidal wave form is discussed. A single phase power system minimizes the wiring, sensing, and control complexities required in a multi-sourced redundantly distributed power system. The single phase addresses only the distribution link; mulitphase lower frequency inputs and outputs accommodation techniques are described. While the 440 V operating potential was initially selected for aircraft operating below 50,000 ft, this potential also appears suitable for space power systems. This voltage choice recognizes a reasonable upper limit for semiconductor ratings, yet will direct synthesis of 220 V, 3 power. A 20 kHz operating frequency was selected to be above the range of audibility, minimize the weight of reactive components, yet allow the construction of single power stages of 25 to 30 kW. The regulated sinusoidal distribution system has several advantages. With a regulated voltage, most ac/dc conversions involve rather simple transformer rectifier applications. A sinusoidal distribution system, when used in conjunction with zero crossing switching, represents a minimal source of EMI. The present state of 20 kHz power technology includes computer controls of voltage and/or frequency, low inductance cable, current limiting circuit protection, bi-directional power flow, and motor/generator operating using standard induction machines. A status update and description of each of these items and their significance is presented.
Code of Federal Regulations, 2013 CFR
2013-10-01
... only. (f) Frequency assignments for Flight Test VHF Stations may be based on either 8.33 kHz or 25 kHz spacing. Assignable frequencies include the interstitial frequencies 8.33 kHz from the VHF frequencies listed in paragraphs (a) and (b) of this section. Each 8.33 kHz interstitial frequency is subject to the...
Code of Federal Regulations, 2012 CFR
2012-10-01
... only. (f) Frequency assignments for Flight Test VHF Stations may be based on either 8.33 kHz or 25 kHz spacing. Assignable frequencies include the interstitial frequencies 8.33 kHz from the VHF frequencies listed in paragraphs (a) and (b) of this section. Each 8.33 kHz interstitial frequency is subject to the...
Code of Federal Regulations, 2011 CFR
2011-10-01
... only. (f) Frequency assignments for Flight Test VHF Stations may be based on either 8.33 kHz or 25 kHz spacing. Assignable frequencies include the interstitial frequencies 8.33 kHz from the VHF frequencies listed in paragraphs (a) and (b) of this section. Each 8.33 kHz interstitial frequency is subject to the...
Code of Federal Regulations, 2014 CFR
2014-10-01
... only. (f) Frequency assignments for Flight Test VHF Stations may be based on either 8.33 kHz or 25 kHz spacing. Assignable frequencies include the interstitial frequencies 8.33 kHz from the VHF frequencies listed in paragraphs (a) and (b) of this section. Each 8.33 kHz interstitial frequency is subject to the...
47 CFR 18.301 - Operating frequencies.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL INDUSTRIAL, SCIENTIFIC, AND MEDICAL EQUIPMENT Technical... as indicated in § 18.303. The following frequency bands, in accordance with § 2.106 of the rules, are... ±15 kHz frequency band is subject to the conditions of footnote 524 of the Table of Allocations. See...
47 CFR 78.111 - Frequency tolerance.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES CABLE TELEVISION RELAY... shall maintain their operating frequency within 0.0005% the visual carrier, and the aural carrier shall be 4.5 MHz ±1 kHz above the visual carrier frequency. [52 FR 7145, Mar. 9, 1987, as amended at 68 FR...
Wide-band current preamplifier for conductance measurements with large input capacitance.
Kretinin, Andrey V; Chung, Yunchul
2012-08-01
A wide-band current preamplifier based on a composite operational amplifier is proposed. It has been shown that the bandwidth of the preamplifier can be significantly increased by enhancing the effective open-loop gain. The described 10(7) V/A current gain preamplifier had the bandwidth of about 100 kHz with the 1 nF input shunt capacitance. The measured preamplifier current noise was 46 fA/√Hz at 1 kHz, close to the design noise minimum. The voltage noise was found to be about 2.9 nV/√Hz at 1 kHz, which is in a good agreement with the value expected for the particular operational amplifier used in the input stage. By analysing the total produced noise we found that the optimal frequency range suitable for the fast lock-in measurements is from 1 kHz to 2 kHz. To obtain the same signal-to-noise ratio, the reported preamplifier requires ~10% of the integration time needed in measurements made with a conventional preamplifier.
NASA Technical Reports Server (NTRS)
1972-01-01
A study of frequency division multiplexing (FDM) systems was made for the purpose of determining the system performance that can be obtained with available state of the art components. System performance was evaluated on the basis of past experience, system analysis, and component evaluation. The system study was specifically directed to the area of FDM systems using subcarrier channel frequencies from 4 kHz to 200 kHz and channel information bandwidths of dc to 1, 2, 4, 8, and 16 kHz. The evaluation also assumes that the demodulation will be from a tape recorder which produces frequency modulation of + or - 1% on the signal due to the tape recorder wow and flutter. For the modulation system it is assumed that the pilot and carrier channel frequencies are stable to within + or - .005% and that the FM on the channel carriers is negligible. The modulator system was evaluated for the temperature range of -20 degree to +85 degree while the demodulator system was evaluated for operation at room temperature.
Ultrasound pressure distributions generated by high frequency transducers in large reactors.
Leong, Thomas; Coventry, Michael; Swiergon, Piotr; Knoerzer, Kai; Juliano, Pablo
2015-11-01
The performance of an ultrasound reactor chamber relies on the sound pressure level achieved throughout the system. The active volume of a high frequency ultrasound chamber can be determined by the sound pressure penetration and distribution provided by the transducers. This work evaluated the sound pressure levels and uniformity achieved in water by selected commercial scale high frequency plate transducers without and with reflector plates. Sound pressure produced by ultrasonic plate transducers vertically operating at frequencies of 400 kHz (120 W) and 2 MHz (128 W) was characterized with hydrophones in a 2 m long chamber and their effective operating distance across the chamber's vertical cross section was determined. The 2 MHz transducer produced the highest pressure amplitude near the transducer surface, with a sharp decline of approximately 40% of the sound pressure occurring in the range between 55 and 155 mm from the transducer. The placement of a reflector plate 500 mm from the surface of the transducer was shown to improve the sound pressure uniformity of 2 MHz ultrasound. Ultrasound at 400 kHz was found to penetrate the fluid up to 2 m without significant losses. Furthermore, 400 kHz ultrasound generated a more uniform sound pressure distribution regardless of the presence or absence of a reflector plate. The choice of the transducer distance to the opposite reactor wall therefore depends on the transducer plate frequency selected. Based on pressure measurements in water, large scale 400 kHz reactor designs can consider larger transducer distance to opposite wall and larger active cross-section, and therefore can reach higher volumes than when using 2 MHz transducer plates. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.
An operational amplifier B1404UD1A-1 in the patch-clamp current-to-voltage converter.
Korzun, A M; Rozinov, S V; Abashin, G I
1997-01-01
The applicability of the home-made operational amplifier B1404UD1A-1 in a patch-clamp current-to-voltage converter was analyzed. Its parameters (background noise, input bias current, and gain-bandwidth product) were estimated. Schematic solutions and practical recommendations for the use of this amplifier in a current-to-voltage converter were given. Based on the background noise and frequency parameters of the converter, we found that this device can be used for measuring ion channel currents with a high sensitivity and within a broad frequency range (0.055 pA, to 1 kHz; 0.4 pA, to 10 kHz). An example of the converter application in experiments is given.
NASA Astrophysics Data System (ADS)
Nalladega, V.; Na, J. K.; Druffner, C.
2011-06-01
Interdigital transducers (IDT) generate and receive ultrasonic surface waves without the complexity involved with secondary devices such as angled wedges or combs. The IDT sensors have been successfully applied for the NDE of homogeneous materials like metals in order to detect cracks and de-bond. However, these transducers have not been yet adapted for complex and anisotropic materials like fiber-reinforced composites. This work presents the possibility of using IDT sensors for monitoring structural damages in wind turbine blades, typically made of fiberglass composites. IDT sensors with a range of operating frequency between 250 kHz and 1 MHz are initially tested on representative composite test panels for ultrasonic surface wave properties including beam spread, propagation distance and effect of material's anisotropy. Based on these results, an optimum frequency range for the IDT sensor is found to be 250-500 kHz. Subsequently, IDT sensors with operating frequency 500 kHz are used to detect and quantify artificial defects created in the composite test samples. Discussions are made on the interaction of ultrasonic fields with these defects along with the effects of fiber directionality and composite layer stacking.
NASA Astrophysics Data System (ADS)
Miyata, Tsuyoshi; Iwata, Tetsuo; Araki, Tsutomu
2006-01-01
We propose a reflection-type pulse oximeter, which employs two pairs of a light-emitting diode (LED) and a gated avalanche photodiode (APD). One LED is a red one with an emission wavelength λ = 635 nm and the other is a near-infrared one with that λ = 945 nm, which are both driven with a pulse mode at a frequency f (=10 kHz). Superposition of a transistor-transistor-logic (TTL) gate pulse on a direct-current (dc) bias, which is set so as not exceeding the breakdown voltage of each APD, makes the APD work in a gain-enhanced operation mode. Each APD is gated at a frequency 2f (=20 kHz) and its output signal is fed into a laboratory-made lock-in amplifier that works in synchronous with the pulse modulation signal of each LED at a frequency f (=10 kHz). A combination of the gated APD and the lock-in like signal detection scheme is useful for the reflection-type pulse oximeter thanks to the capability of detecting a weak signal against a large background (BG) light.
47 CFR 90.265 - Assignment and use of frequencies in the bands allocated for Federal use.
Code of Federal Regulations, 2010 CFR
2010-10-01
... bandwidth greater than 11.25 kHz until January 1, 2013. Such operations are limited by paragraphs (a)(6) and..., 2013, subject to the requirements of paragraphs (a)(6) and (a)(7) of this section. (b) The following..., 2005, and January 1, 2013, existing systems with an authorized bandwidth of greater than 11.25 kHz...
47 CFR 90.265 - Assignment and use of frequencies in the bands allocated for Federal use.
Code of Federal Regulations, 2011 CFR
2011-10-01
... bandwidth greater than 11.25 kHz until January 1, 2013. Such operations are limited by paragraphs (a)(6) and..., 2013, subject to the requirements of paragraphs (a)(6) and (a)(7) of this section. (b) The following..., 2005, and January 1, 2013, existing systems with an authorized bandwidth of greater than 11.25 kHz...
NASA Astrophysics Data System (ADS)
Ahn, C. H.; Nitzan, S.; Ng, E. J.; Hong, V. A.; Yang, Y.; Kimbrell, T.; Horsley, D. A.; Kenny, T. W.
2014-12-01
In this paper, we explore the effects of electrostatic parametric amplification on a high quality factor (Q > 100 000) encapsulated disk resonator gyroscope (DRG), fabricated in <100> silicon. The DRG was operated in the n = 2 degenerate wineglass mode at 235 kHz, and electrostatically tuned so that the frequency split between the two degenerate modes was less than 100 mHz. A parametric pump at twice the resonant frequency is applied to the sense axis of the DRG, resulting in a maximum scale factor of 156.6 μV/(°/s), an 8.8× improvement over the non-amplified performance. When operated with a parametric gain of 5.4, a minimum angle random walk of 0.034°/√h and bias instability of 1.15°/h are achieved, representing an improvement by a factor of 4.3× and 1.5×, respectively.
47 CFR 95.629 - LPRS transmitter frequencies.
Code of Federal Regulations, 2014 CFR
2014-10-01
... is 25 kHz. Channel No. Center frequency (MHz) 1 216.0125 2 216.0375 3 216.0625 4 216.0875 5 216.1125... extra band frequencies. The channel bandwidth is 50 kHz. Channel No. Center frequency (MHz) 41 216.025... frequencies. The channel bandwidth is 5 kHz and the authorized bandwidth is 4 kHz. Channel No. Center...
47 CFR 95.629 - LPRS transmitter frequencies.
Code of Federal Regulations, 2011 CFR
2011-10-01
... is 25 kHz. Channel No. Center frequency (MHz) 1 216.0125 2 216.0375 3 216.0625 4 216.0875 5 216.1125... extra band frequencies. The channel bandwidth is 50 kHz. Channel No. Center frequency (MHz) 41 216.025... frequencies. The channel bandwidth is 5 kHz and the authorized bandwidth is 4 kHz. Channel No. Center...
47 CFR 95.629 - LPRS transmitter frequencies.
Code of Federal Regulations, 2013 CFR
2013-10-01
... is 25 kHz. Channel No. Center frequency (MHz) 1 216.0125 2 216.0375 3 216.0625 4 216.0875 5 216.1125... extra band frequencies. The channel bandwidth is 50 kHz. Channel No. Center frequency (MHz) 41 216.025... frequencies. The channel bandwidth is 5 kHz and the authorized bandwidth is 4 kHz. Channel No. Center...
47 CFR 95.629 - LPRS transmitter frequencies.
Code of Federal Regulations, 2012 CFR
2012-10-01
... is 25 kHz. Channel No. Center frequency (MHz) 1 216.0125 2 216.0375 3 216.0625 4 216.0875 5 216.1125... extra band frequencies. The channel bandwidth is 50 kHz. Channel No. Center frequency (MHz) 41 216.025... frequencies. The channel bandwidth is 5 kHz and the authorized bandwidth is 4 kHz. Channel No. Center...
47 CFR 95.629 - LPRS transmitter frequencies.
Code of Federal Regulations, 2010 CFR
2010-10-01
... is 25 kHz. Channel No. Center frequency (MHz) 1 216.0125 2 216.0375 3 216.0625 4 216.0875 5 216.1125... extra band frequencies. The channel bandwidth is 50 kHz. Channel No. Center frequency (MHz) 41 216.025... frequencies. The channel bandwidth is 5 kHz and the authorized bandwidth is 4 kHz. Channel No. Center...
Production of particulates from transducer erosion: implications on food safety.
Mawson, Raymond; Rout, Manoj; Ripoll, Gabriela; Swiergon, Piotr; Singh, Tanoj; Knoerzer, Kai; Juliano, Pablo
2014-11-01
The formation of metallic particulates from erosion was investigated by running a series of transducers at various frequencies in water. Two low frequency transducer sonotrodes were run for 7.5h at 18kHz and 20kHz. Three high frequency plates operating at megasonic frequencies of 0.4MHz, 1MHz, and 2MHz were run over a 7days period. Electrical conductivity and pH of the solution were measured before and after each run. A portion of the non-sonicated and treated water was partially evaporated to achieve an 80-fold concentration of particles and then sieved through nano-filters of 0.1μm, 0.05μm, and 0.01μm. An aliquot of the evaporated liquid was also completely dried on strips of carbon tape to determine the presence of finer particles post sieving. An aliquot was analyzed for detection of 11 trace elements by Inductively Coupled Plasma Mass Spectroscopy (ICPMS). The filters and carbon tapes were analyzed by FE-SEM imaging to track the presence of metals by EDS (Energy Dispersive Spectroscopy) and measure the particle size and approximate composition of individual particles detected. Light microscopy visualization was used to calculate the area occupied by the particles present in each filter and high resolution photography was used for visualization of sonotrode surfaces. The roughness of all transducers before and after sonication was tested through profilometry. No evidence of formation of nano-particles was found at any tested frequency. High amounts of metallic micron-sized particles at 18kHz and 20kHz formed within a day, while after 7day runs only a few metallic micro particles were detected above 0.4MHz. Erosion was corroborated by an increase in roughness in the 20kHz tip after ultrasound. The elemental analysis showed that metal leach occurred but values remained below accepted drinking water limits, even after excessively long exposure to ultrasound. With the proviso that the particles measured here were only characterized in two dimensions and could be nanoparticulate in terms of the third dimension, this research suggests that there are no serious health implications resulting from the formation of nanoparticles under the evaluation conditions. Therefore, high frequency transducer plates can be safely operated in direct contact with foods. However, due to significant production of metallic micro-particulates, redesign of lower frequency sonotrodes and reaction chambers is advised to enable operation in various food processing direct-contact applications. Copyright © 2014 Elsevier B.V. All rights reserved.
Er:YAG laser technology for remote sensing applications
NASA Astrophysics Data System (ADS)
Chen, Moran; Burns, Patrick M.; Litvinovitch, Viatcheslav; Storm, Mark; Sawruk, Nicholas W.
2016-10-01
Fibertek has developed an injection locked, resonantly pumped Er:YAG solid-state laser operating at 1.6 μm capable of pulse repetition rates of 1 kHz to 10 kHz for airborne methane and water differential absorption lidars. The laser is resonantly pumped with a fiber-coupled 1532 nm diode laser minimizing the quantum defect and thermal loading generating tunable single-frequency output of 1645-1646 nm with a linewidth of < 100 MHz. The frequency-doubled 1.6 μm Er:YAG laser emits wavelengths in the 822-823 nm spectrum, coincident with water vapor lines. Various cavity designs were studied and optimized for compactness and performance, with the optimal design being an injection seeded and locked five-mirror ring cavity. The laser generated 4 W of average power at pulse repetition frequencies (PRFs) of 1 kHz and 10 kHz, corresponding to 4 mJ and 400 μJ pulse energies, respectively. The 1645 nm was subsequently frequency doubled to 822.5 nm with a 600 pm tuning range covering multiple water absorption lines, with a pulse energy of 1 mJ and a pulse repetition frequency of 1 kHz. The resonator cavity was locked to the seed wavelength via a Pound Drever Hall (PDH) technique and an analog Proportional Integral Derivative (PID) Controller driving a high-bandwidth piezoelectric (PZT)-mounted cavity mirror. Two seed sources lasing on and off the methane absorption line were optically switched to tune the resonator wavelength on and off the methane absorption line between each sequential output pulse. The cavity locking servo maintained the cavity resonance for each pulse.
Single-Frequency Narrow Linewidth 2 Micron Fiber Laser
NASA Technical Reports Server (NTRS)
Jiang, Shibin (Inventor); Spiegelberg, Christine (Inventor); Luo, Tao (Inventor)
2006-01-01
A compact single frequency, single-mode 2 .mu.m fiber laser with narrow linewidth, <100 kHz and preferably <100 kHz, is formed with a low phonon energy glass doped with triply ionized rare-earth thulium and/or holmium oxide and fiber gratings formed in sections of passive silica fiber and fused thereto. Formation of the gratings in passive silica fiber both facilitates splicing to other optical components and reduces noise thus improving linewidth. An increased doping concentration of 0.5 to 15 wt. % for thulium, holmium or mixtures thereof produces adequate gain, hence output power levels for fiber lengths less than 5 cm and preferably less than 3 cm to enable single-frequency operation.
Xue, L J; Yang, A C; Chen, H; Huang, W X; Guo, J J; Liang, X Y; Chen, Z Q; Zheng, Q L
2017-11-20
Objective: Study of the results and the degree on occupational noise-induced deafness in-to the different high frequency hearing threshold weighted value, in order to provide theoretical basis for the re-vision of diagnostic criteria on occupational noise-induced deafness. Methods: A retrospective study was con-ducted to investigate the cases on the diagnosis of occupational noise-induced deafness in Guangdong province hospital for occupational disease prevention and treatment from January 2016 to January 2017. Based on the re-sults of the 3 hearing test for each test interval greater than 3 days in the hospital, the best threshold of each frequency was obtained, and based on the diagnostic criteria of occupational noise deafness in 2007 edition, Chi square test, t test and variance analysis were used to measure SPSS21.0 data, their differences are tested among the means of speech frequency and the high frequency weighted value into different age group, noise ex-posure group, and diagnostic classification between different dimensions. Results: 1. There were totally 168 cases in accordance with the study plan, male 154 cases, female 14 cases, the average age was 41.18 ±6.07 years old. 2. The diagnosis rate was increased into the weighted value of different high frequency than the mean value of pure speech frequency, the weighted 4 kHz frequency increased by 13.69% (χ(2)=9.880, P =0.002) , 6 kHz increased by 15.47% (χ(2)=9.985, P =0.002) and 4 kHz+6 kHz increased by15.47% (χ(2)=9.985, P =0.002) , the difference was statistically significant. The diagnostic rate of different high threshold had no obvious differ-ence between the genders. 3. The age groups were divided into less than or equal to 40years old group (A group) and 40-50 years old group (group B) , there were higher the diagnostic rate between high frequency weighted 4 kHz (A group χ(2)=3.380, P =0.050; B group χ(2)=4.054, P =0.032) , weighted 6 kHz (A group χ(2)=6.362, P =0.012; B group χ(2)=4.054, P =0.032) , high frequency weighted 4 kHz+6 kHz (A group χ(2)=6.362, P =0.012; B group χ(2)=4.054, P =0.032) than those of speech frequency average value in the same group on oc-cupational noise-induced deafness diagnosis rate, the difference was statistically significant. There was no sig-nificant difference between age groups (χ(2)=2.265, P =0.944) . 4. The better ear's mean value of pure speech fre-quency and the weighted values into different high frequency of working years on each group were compared, working years more than 10 years group was significantly higher than that of average thresholds of each frequen-cy band in 3-5 group ( F =2.271, P =0.001) , 6-10 group ( F =1.563, P =0.046) , the difference was statistically significant. The different high frequency weighted values were higher than those of the mean value of pure speech frequency, and the high frequency weighted 4 kHz+6 kHz had the highest frequency difference, with an average increase of 2.83 dB. 5. The diagnostic rate into weighted different high frequency was higher in the mild, moderate and severe grades than in the pure speech frequency. In the comparison of diagnosis for mild occupational noise-induced deafness, in addition to the weighted 3 kHz high frequency (χ(2)=3.117, P =0.077) had no significant difference, the weighted 4 kHz (χ(2)=10.835, P =0.001) , 6 kHz (χ(2)=9.985, P =0.002) , 3 kHz+4 kHz (χ(2)=6.315, P =0.012) , 3 kHz+6 kHz (χ(2)=6.315, P =0.012) , 4 kHz+6 kHz (χ(2)=9.985, P =0.002) , 3 kHz+4 kHz+6 kHz (χ(2)=7.667, P =0.002) were significantly higher than the diagnosis rate of the mean value of pure speech frequency. There was no significant difference between the two groups in the moderate and se-vere grades ( P >0.05) . Conclusion: Bring into different high frequency hearing threshold weighted value in-creases the diagnostic rate of occupational noise-induced deafness, the weighted 4 kHz, 6 kHz and 4 kHz+ 6 kHz high frequency value affects the result greatly, and the weighted 4 kHz+6 kHz high frequency hearing threshold value is maximum the effect on occupational noise-induced deafness diagnosis.
47 CFR 90.253 - Use of frequency 5167.5 kHz.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Use of frequency 5167.5 kHz. 90.253 Section 90.253 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES... frequency 5167.5 kHz. The frequency 5167.5 kHz may be used by any station authorized under this part to...
47 CFR 90.253 - Use of frequency 5167.5 kHz.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 5 2013-10-01 2013-10-01 false Use of frequency 5167.5 kHz. 90.253 Section 90.253 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES... frequency 5167.5 kHz. The frequency 5167.5 kHz may be used by any station authorized under this part to...
47 CFR 90.253 - Use of frequency 5167.5 kHz.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Use of frequency 5167.5 kHz. 90.253 Section 90.253 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES... frequency 5167.5 kHz. The frequency 5167.5 kHz may be used by any station authorized under this part to...
47 CFR 90.253 - Use of frequency 5167.5 kHz.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false Use of frequency 5167.5 kHz. 90.253 Section 90.253 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES... frequency 5167.5 kHz. The frequency 5167.5 kHz may be used by any station authorized under this part to...
47 CFR 90.253 - Use of frequency 5167.5 kHz.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false Use of frequency 5167.5 kHz. 90.253 Section 90.253 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES... frequency 5167.5 kHz. The frequency 5167.5 kHz may be used by any station authorized under this part to...
47 CFR 101.107 - Frequency tolerance.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE... to private operational fixed point-to-point microwave and stations providing MVDDS. 5 For private operational fixed point-to-point microwave systems, with a channel greater than or equal to 50 KHz bandwidth...
76 FR 33653 - Maritime Communications
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-09
... maritime navigation safety communications system through which marine vessels automatically transmit... may also operate on 12.5 kHz offset frequencies in areas where the licensee is authorized on both... operate on the interstitial channel between Channels 27 and 87 and the interstitial channel between...
Doksaeter, Lise; Rune Godo, Olav; Olav Handegard, Nils; Kvadsheim, Petter H; Lam, Frans-Peter A; Donovan, Carl; Miller, Patrick J O
2009-01-01
Military antisubmarine sonars produce intense sounds within the hearing range of most clupeid fish. The behavioral reactions of overwintering herring (Clupea harengus) to sonar signals of two different frequency ranges (1-2 and 6-7 kHz), and to playback of killer whale feeding sounds, were tested in controlled exposure experiments in Vestfjorden, Norway, November 2006. The behavior of free ranging herring was monitored by two upward-looking echosounders. A vessel towing an operational naval sonar source approached and passed over one of them in a block design setup. No significant escape reactions, either vertically or horizontally, were detected in response to sonar transmissions. Killer whale feeding sounds induced vertical and horizontal movements of herring. The results indicate that neither transmission of 1-2 kHz nor 6-7 kHz have significant negative influence on herring on the received sound pressure level tested (127-197 and 139-209 dB(rms) re 1 microPa, respectively). Military sonars of such frequencies and source levels may thus be operated in areas of overwintering herring without substantially affecting herring behavior or herring fishery. The avoidance during playback of killer whale sounds demonstrates the nature of an avoidance reaction and the ability of the experimental design to reveal it.
Code of Federal Regulations, 2010 CFR
2010-10-01
... for NBDP and data transmissions (kHz) 4 MHz Coast Ship 6 MHz Coast Ship 8 MHz Coast Ship 12 MHz Coast... frequencies. Non-Paired NBDP Channels (kHz) Channel series: 1 4202.5 6300.5 8396.5 12560.0 16785.0 18893.0....0 (c) Distress and calling. The frequencies 2174.5 kHz, 4177.5 kHz, 6268.0 kHz, 8376.5 kHz, 12520.0...
Code of Federal Regulations, 2013 CFR
2013-10-01
... for NBDP and data transmissions (kHz) 4 MHz Coast Ship 6 MHz Coast Ship 8 MHz Coast Ship 12 MHz Coast... frequencies. Non-Paired NBDP Channels (kHz) Channel series: 1 4202.5 6300.5 8396.5 12560.0 16785.0 18893.0....0 (c) Distress and calling. The frequencies 2174.5 kHz, 4177.5 kHz, 6268.0 kHz, 8376.5 kHz, 12520.0...
Code of Federal Regulations, 2012 CFR
2012-10-01
... for NBDP and data transmissions (kHz) 4 MHz Coast Ship 6 MHz Coast Ship 8 MHz Coast Ship 12 MHz Coast... frequencies. Non-Paired NBDP Channels (kHz) Channel series: 1 4202.5 6300.5 8396.5 12560.0 16785.0 18893.0....0 (c) Distress and calling. The frequencies 2174.5 kHz, 4177.5 kHz, 6268.0 kHz, 8376.5 kHz, 12520.0...
Code of Federal Regulations, 2014 CFR
2014-10-01
... for NBDP and data transmissions (kHz) 4 MHz Coast Ship 6 MHz Coast Ship 8 MHz Coast Ship 12 MHz Coast... frequencies. Non-Paired NBDP Channels (kHz) Channel series: 1 4202.5 6300.5 8396.5 12560.0 16785.0 18893.0....0 (c) Distress and calling. The frequencies 2174.5 kHz, 4177.5 kHz, 6268.0 kHz, 8376.5 kHz, 12520.0...
Code of Federal Regulations, 2011 CFR
2011-10-01
... for NBDP and data transmissions (kHz) 4 MHz Coast Ship 6 MHz Coast Ship 8 MHz Coast Ship 12 MHz Coast... frequencies. Non-Paired NBDP Channels (kHz) Channel series: 1 4202.5 6300.5 8396.5 12560.0 16785.0 18893.0....0 (c) Distress and calling. The frequencies 2174.5 kHz, 4177.5 kHz, 6268.0 kHz, 8376.5 kHz, 12520.0...
47 CFR 73.509 - Prohibited overlap.
Code of Federal Regulations, 2012 CFR
2012-10-01
... mV/m (60 dBu)0.1 mV/m (40 dBu) 200 kHz 0.5 mV/m (54 dBu)1 mV/m (60 dBu)1 1 mV/m (60 dBu)0.5 mV/m (54...-channel 0.1 mV/m (40 dBu) 1 mV/m (60 dBu). 200 kHz 0.5 mV/m (54 dBu) 1 mV/m (60 dBu). 400 kHz 10 mV/m (80... Commission and operating in the reserved band (Channels 200-220, inclusive) as set forth below: Frequency...
47 CFR 73.509 - Prohibited overlap.
Code of Federal Regulations, 2013 CFR
2013-10-01
... mV/m (60 dBu)0.1 mV/m (40 dBu) 200 kHz 0.5 mV/m (54 dBu)1 mV/m (60 dBu)1 1 mV/m (60 dBu)0.5 mV/m (54...-channel 0.1 mV/m (40 dBu) 1 mV/m (60 dBu). 200 kHz 0.5 mV/m (54 dBu) 1 mV/m (60 dBu). 400 kHz 10 mV/m (80... Commission and operating in the reserved band (Channels 200-220, inclusive) as set forth below: Frequency...
47 CFR 73.509 - Prohibited overlap.
Code of Federal Regulations, 2014 CFR
2014-10-01
... mV/m (60 dBu)0.1 mV/m (40 dBu) 200 kHz 0.5 mV/m (54 dBu)1 mV/m (60 dBu)1 1 mV/m (60 dBu)0.5 mV/m (54...-channel 0.1 mV/m (40 dBu) 1 mV/m (60 dBu). 200 kHz 0.5 mV/m (54 dBu) 1 mV/m (60 dBu). 400 kHz 10 mV/m (80... Commission and operating in the reserved band (Channels 200-220, inclusive) as set forth below: Frequency...
Behavioral responses by grey seals (Halichoerus grypus) to high frequency sonar.
Hastie, Gordon D; Donovan, Carl; Götz, Thomas; Janik, Vincent M
2014-02-15
The use of high frequency sonar is now commonplace in the marine environment. Most marine mammals rely on sound to navigate, and for detecting prey, and there is the potential that the acoustic signals of sonar could cause behavioral responses. To investigate this, we carried out behavioral response tests with grey seals to two sonar systems (200 and 375 kHz systems). Results showed that both systems had significant effects on the seals behavior; when the 200 kHz sonar was active, seals spent significantly more time hauled out and, although seals remained swimming during operation of the 375 kHz sonar, they were distributed further from the sonar. The results show that although peak sonar frequencies may be above marine mammal hearing ranges, high levels of sound can be produced within their hearing ranges that elicit behavioral responses; this has clear implications for the widespread use of sonar in the marine environment. Copyright © 2013 Elsevier Ltd. All rights reserved.
Schmuziger, Nicolas; Probst, Rudolf; Smurzynski, Jacek
2004-04-01
The purposes of the study were: (1) To evaluate the intrasession test-retest reliability of pure-tone thresholds measured in the 0.5-16 kHz frequency range for a group of otologically healthy subjects using Sennheiser HDA 200 circumaural and Etymotic Research ER-2 insert earphones and (2) to compare the data with existing criteria of significant threshold shifts related to ototoxicity and noise-induced hearing loss. Auditory thresholds in the frequency range from 0.5 to 6 kHz and in the extended high-frequency range from 8 to 16 kHz were measured in one ear of 138 otologically healthy subjects (77 women, 61 men; mean age, 24.4 yr; range, 12-51 yr) using HDA 200 and ER-2 earphones. For each subject, measurements of thresholds were obtained twice for both transducers during the same test session. For analysis, the extended high-frequency range from 8 to 16 kHz was subdivided into 8 to 12.5 and 14 to 16 kHz ranges. Data for each frequency and frequency range were analyzed separately. There were no significant differences in repeatability for the two transducer types for all frequency ranges. The intrasession variability increased slightly, but significantly, as frequency increased with the greatest amount of variability in the 14 to 16 kHz range. Analyzing each individual frequency, variability was increased particularly at 16 kHz. At each individual frequency and for both transducer types, intrasession test-retest repeatability from 0.5 to 6 kHz and 8 to 16 kHz was within 10 dB for >99% and >94% of measurements, respectively. The results indicated a false-positive rate of <3% in reference to the criteria for cochleotoxicity for both transducer types. In reference to the Occupational Safety and Health Administration Standard Threshold Shift criteria for noise-induced hazards, the results showed a minor false-positive rate of <1% for the HDA 200. Repeatability was similar for both transducer types. Intrasession test-retest repeatability from 0.5 to 12.5 kHz at each individual frequency including the frequency range susceptible to noise-induced hearing loss was excellent for both transducers. Repeatability was slightly, but significantly poorer in the frequency range from 14 to 16 kHz compared with the frequency ranges from 0.5 to 6 or 8 to 12.5 kHz. Measurements in the extended high-frequency range from 8 to 14 kHz, but not up to 16 kHz, may be recommended for monitoring purposes.
Magnetic Search Coil (MSC) of Plasma Wave Experiment (PWE) aboard the Arase (ERG) satellite
NASA Astrophysics Data System (ADS)
Ozaki, Mitsunori; Yagitani, Satoshi; Kasahara, Yoshiya; Kojima, Hirotsugu; Kasaba, Yasumasa; Kumamoto, Atsushi; Tsuchiya, Fuminori; Matsuda, Shoya; Matsuoka, Ayako; Sasaki, Takashi; Yumoto, Takahiro
2018-05-01
This paper presents detailed performance values of the Magnetic Search Coil (MSC) that is part of the Plasma Wave Experiment on board the Arase (ERG) satellite. The MSC consists of a three-axis search coil magnetometer with a 200-mm-long magnetic core. The MSC plays a central role in the magnetic field observations, particularly for whistler mode chorus and hiss waves in a few kHz frequency range, which may cause local acceleration and/or rapid loss of radiation belt electrons. Accordingly, the MSC was carefully designed and developed to operate well in harsh radiation environments. To ascertain the wave-normal vectors, polarizations, and refractive indices of the plasma waves in a wide frequency band, the output signals detected by the MSC are fed into the two different wave receivers: one is the WaveForm Capture/Onboard Frequency Analyzer for waveform and spectrum observations in the frequency range from a few Hz up to 20 kHz, and the other is the High Frequency Analyzer for spectrum observations in the frequency range from 10 to 100 kHz. The noise equivalent magnetic induction of the MSC is 20 {fT/Hz}^{1/2} at a frequency of 2 kHz, and the null depth of directionality is - 40 dB, which is equivalent to an angular error less than 1°. The MSC on board the Arase satellite is the first experiment using a current-sensitive preamplifier for probing the plasma waves in the radiation belts.[Figure not available: see fulltext.
47 CFR 90.187 - Trunking in the bands between 150 and 512 MHz.
Code of Federal Regulations, 2010 CFR
2010-10-01
.... 90.187 Section 90.187 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Policies Governing the Assignment of Frequencies... frequencies (base and mobile) that are 15 kHz or less removed from proposed stations that will operate with a...
47 CFR 80.116 - Radiotelephone operating procedures for ship stations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Radiotelephone operating procedures for ship... Procedures-Ship Stations § 80.116 Radiotelephone operating procedures for ship stations. (a) Calling coast stations. (1) Use by ship stations of the frequency 2182 kHz for calling coast stations and for replying to...
47 CFR 80.116 - Radiotelephone operating procedures for ship stations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false Radiotelephone operating procedures for ship... Procedures-Ship Stations § 80.116 Radiotelephone operating procedures for ship stations. (a) Calling coast stations. (1) Use by ship stations of the frequency 2182 kHz for calling coast stations and for replying to...
47 CFR 80.116 - Radiotelephone operating procedures for ship stations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 5 2013-10-01 2013-10-01 false Radiotelephone operating procedures for ship... Procedures-Ship Stations § 80.116 Radiotelephone operating procedures for ship stations. (a) Calling coast stations. (1) Use by ship stations of the frequency 2182 kHz for calling coast stations and for replying to...
47 CFR 80.116 - Radiotelephone operating procedures for ship stations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false Radiotelephone operating procedures for ship... Procedures-Ship Stations § 80.116 Radiotelephone operating procedures for ship stations. (a) Calling coast stations. (1) Use by ship stations of the frequency 2182 kHz for calling coast stations and for replying to...
47 CFR 80.116 - Radiotelephone operating procedures for ship stations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Radiotelephone operating procedures for ship... Procedures-Ship Stations § 80.116 Radiotelephone operating procedures for ship stations. (a) Calling coast stations. (1) Use by ship stations of the frequency 2182 kHz for calling coast stations and for replying to...
A 9.61-W, b-cut Tm,Ho:YAP laser in Q-switched mode operation
NASA Astrophysics Data System (ADS)
Li, Guoxing; Yang, Xining; Zhang, Ziqiu; Zhang, Hongda; Zhang, Liang
2018-02-01
A high energy of b-cut Tm, Ho:YAlO3 laser is reported in the paper. The laser operated in acousto-optical Qswitched mode at 2.12 μm. The output average power of 9.61 W was achieved at the pulse repetition frequency of 10 kHz ,and the power of 11.6 W was acquired in continuous wave mode. Moreover, the energy per pulse of 0.961 mJ in 64.4 ns was acquired at 10 kHz with a 14.92-kW peak power.
Code of Federal Regulations, 2013 CFR
2013-10-01
... traffic control. 325-435 kHz Q RLB Radiobeacons. 410.0 kHz F MA International direction-finding for use outside of United States. 457.0 kHz F MA Working frequency for aircraft on over-water flights. 500.0 kHz F MA International calling and distress frequency for ships and aircraft on over-water flights. 510-535...
Code of Federal Regulations, 2012 CFR
2012-10-01
... traffic control. 325-435 kHz Q RLB Radiobeacons. 410.0 kHz F MA International direction-finding for use outside of United States. 457.0 kHz F MA Working frequency for aircraft on over-water flights. 500.0 kHz F MA International calling and distress frequency for ships and aircraft on over-water flights. 510-535...
Code of Federal Regulations, 2014 CFR
2014-10-01
... traffic control. 325-435 kHz Q RLB Radiobeacons. 410.0 kHz F MA International direction-finding for use outside of United States. 457.0 kHz F MA Working frequency for aircraft on over-water flights. 500.0 kHz F MA International calling and distress frequency for ships and aircraft on over-water flights. 510-535...
Code of Federal Regulations, 2010 CFR
2010-10-01
... traffic control. 325-435 kHz Q RLB Radiobeacons. 410.0 kHz F MA International direction-finding for use outside of United States. 457.0 kHz F MA Working frequency for aircraft on over-water flights. 500.0 kHz F MA International calling and distress frequency for ships and aircraft on over-water flights. 510-535...
Code of Federal Regulations, 2011 CFR
2011-10-01
... traffic control. 325-435 kHz Q RLB Radiobeacons. 410.0 kHz F MA International direction-finding for use outside of United States. 457.0 kHz F MA Working frequency for aircraft on over-water flights. 500.0 kHz F MA International calling and distress frequency for ships and aircraft on over-water flights. 510-535...
Wideband Aural Acoustic Absorbance Predicts Conductive Hearing Loss in Children
Keefe, Douglas H.; Sanford, Chris A.; Ellison, John C.; Fitzpatrick, Denis F.; Gorga, Michael P.
2013-01-01
Objective This study tested the hypothesis that wideband aural absorbance predicts conductive hearing loss (CHL) in children medically classified as having otitis media with effusion. Design Absorbance was measured in the ear canal over frequencies from 0.25 to 8 kHz at ambient pressure or as a swept tympanogram. CHL was defined using criterion air-bone gaps of 20, 25 and 30 dB at octaves from 0.25 to 4 kHz. A likelihood-ratio predictor of CHL was constructed across frequency for ambient absorbance and across frequency and pressure for absorbance tympanometry. Performance was evaluated at individual frequencies and for any frequency at which a CHL was present. Study Sample Absorbance and conventional 226-Hz tympanograms were measured in children of age 3 to 8 years with CHL and with normal hearing. Results Absorbance was smaller at frequencies above 0.7 kHz in the CHL group than the control group. Based on the area under the receiver operating characteristic curve, wideband absorbance in ambient and tympanometric tests were significantly better predictors of CHL than tympanometric width, the best 226-Hz predictor. Accuracies of ambient and tympanometric wideband absorbance did not differ. Conclusions Absorbance accurately predicted CHL in children and was more accurate than conventional 226-Hz tympanometry. PMID:23072655
First results from the NEMO Test Site
NASA Astrophysics Data System (ADS)
Riccobene, Giorgio; NEMO Collaboration
2007-03-01
The NEMO (NEutrino Mediterranean Observatory) Collaboration is constructing, 25 km E from Catania (Sicily) at 2000 m depth, an underwater test site to perform long-term tests of prototypes and new technologies for an underwater high energy neutrino detector in the Mediterranean Sea. In this framework the collaboration deployed and operated an experimental apparatus for on-line monitoring of deep-sea noise. The station is equipped with 4 hydrophones operational in the range 30 Hz - 40 kHz. This interval of frequencies matches the range suitable for acoustic detection of high energy neutrino-induced showers in water. Hydrophone signals are digitized underwater at 96 kHz sampling frequency and 24 bits resolution. A custom software was developed to record data on high resolution 4-channels PCM .le. Data are used to model underwater acoustic noise as a function of frequency and time, a mandatory parametre for future acoustic neutrino detectors. Results indicate that the average noise in the site is compatible with noise produced in condition of sea surface agitation (sea state.)
High Repetition Rate and Frequency Stabilized Ho:YLF Laser for CO2 Differential Absorption Lidar
NASA Technical Reports Server (NTRS)
Bai, Yingxin; Yu, Jirong; Petros, M.; Petzar, Pau; Trieu, Bo; Lee, Hyung; Singh, U.
2009-01-01
High repetition rate operation of an injection seeded Ho:YLF laser has been demonstrated. For 1 kHz operation, the output pulse energy reaches 5.8mJ and the optical-to-optical efficiency is 39% when the pump power is 14.5W.
Code of Federal Regulations, 2014 CFR
2014-10-01
... frequencies (carrier) available to enroute stations serving international flight operations on the Major World... 5658.0 13294.0 6559.0 17961.0 6574.0 (13) Indian Ocean (INO): kHz 3476.0 13306.0 5634.0 17961.0 8879.0... world for control of the regularity and efficiency of flight and safety of aircraft. World-wide...
Sakamoto, Toshiro; Endo, Shogo
2013-01-01
Previous studies have shown that deep cerebellar nuclei (DCN)-lesioned mice develop conditioned responses (CR) on delay eyeblink conditioning when a salient tone conditioned stimulus (CS) is used, which suggests that the cerebellum potentially plays a role in more complicated cognitive functions. In the present study, we examined the role of DCN in tone frequency discrimination in the delay eyeblink-conditioning paradigm. In the first experiment, DCN-lesioned and sham-operated mice were subjected to standard simple eyeblink conditioning under low-frequency tone CS (LCS: 1 kHz, 80 dB) or high-frequency tone CS (HCS: 10 kHz, 70 dB) conditions. DCN-lesioned mice developed CR in both CS conditions as well as sham-operated mice. In the second experiment, DCN-lesioned and sham-operated mice were subjected to two-tone discrimination tasks, with LCS+ (or HCS+) paired with unconditioned stimulus (US), and HCS− (or LCS−) without US. CR% in sham-operated mice increased in LCS+ (or HCS+) trials, regardless of tone frequency of CS, but not in HCS− (or LCS−) trials. The results indicate that sham-operated mice can discriminate between LCS+ and HCS− (or HCS+ and LCS−). In contrast, DCN-lesioned mice showed high CR% in not only LCS+ (or HCS+) trials but also HCS− (or LCS−) trials. The results indicate that DCN lesions impair the discrimination between tone frequency in eyeblink conditioning. Our results suggest that the cerebellum plays a pivotal role in the discrimination of tone frequency. PMID:23555821
Non-invasive transcranial stimulation of rat abducens nerve by focused ultrasound
Kim, Hyungmin; Taghados, Seyed Javid; Fischer, Krisztina; Maeng, Lee-So; Park, Shinsuk; Yoo, Seung-Schik
2012-01-01
Non-pharmacological and non-surgical transcranial modulation of the nerve function may provide new opportunities in evaluation and treatment of cranial nerve diseases. This study investigates the possibility of using low-intensity transcranial focused ultrasound (FUS) to selectively stimulate the rat abducens nerve located above the base of the skull. FUS (frequencies of 350 kHz and 650 kHz) operating in a pulsed mode was applied to the abducens nerve of Sprague-Dawley rats under stereotactic guidance. The abductive eyeball movement ipsilateral to the side of sonication was observed at 350 kHz, using the 0.36 msec tone burst duration (TBD), 1.5 kHz pulse repetition frequency (PRF), and the overall sonication duration of 200 msec. Histological and behavioral monitoring showed no signs of disruption in the blood brain barrier (BBB) as well as no damage to the nerves and adjacent brain tissue resulting from the sonication. As a novel functional neuro-modulatory modality, the pulsed application of FUS has potential in diagnostic and therapeutic applications in diseases of the peripheral nervous system. PMID:22763009
NASA Astrophysics Data System (ADS)
Ozevin, Didem; Greve, David W.; Oppenheim, Irving J.; Pessiki, Stephen
2005-05-01
We describe the design, fabrication, testing and application (in structural experiments) of our 2004 (second generation) MEMS device, designed for acoustic emission sensing based upon experiments with our 2002 (first generation) device. Both devices feature a suite of resonant-type transducers in the frequency range between 100 kHz and 1 MHz. The 2002 device was designed to operate in an evacuated housing because of high squeeze film damping, as confirmed in our earlier experiments. In additional studies involving the 2002 device, experimental simulation of acoustic emissions in a steel plate, using pencil lead break or ball impact loading, showed that the transducers in the frequency range of 100 kHz-500 kHz presented clearer output signals than the transducers with frequencies higher than 500 kHz. Using the knowledge gained from the 2002 device, we designed and fabricated our second generation device in 2004 using the multi-user polysilicon surface micromachining (MUMPs) process. The 2004 device has 7 independent capacitive type transducers, compared to 18 independent transducers in the 2002 device, including 6 piston type transducers in the frequency range of 100 kHz to 500 kHz and 1 piston type transducer at 1 MHz to capture high frequency information. Piston type transducers developed in our research have two uncoupled modes so that twofold information can be acquired from a single transducer. In addition, the piston shape helps to reduce residual stress effect of surface micromachining process. The center to center distance between etch holes in the vibrating plate was reduced from 30 μm to 13 μm, in order to reduce squeeze film damping. As a result, the Q factor under atmospheric pressure for the 100 kHz transducer was increased to 2.37 from 0.18, and therefore the vacuum housing has been eliminated from the 2004 device. Sensitivities of transducers were also increased, by enlarging transducer area, in order to capture significant small amplitude acoustic emission events. The average individual transducer area in the 2004 device was increased to 6.97 mm2 as compared to 2.51 mm2 in the 2002 device. In this paper, we report the new experimental results on the characterization of the 2004 device and compare them with analytical results. We show improvements in sensitivity as measured by capacitance and as measured by pencil lead break experiments. Improvement in damping is also evaluated by admittance measurement in atmosphere. Pencil lead break experiments also show that transducers can operate in atmospheric pressure. Finally, we apply the device to acoustic emission experiments on crack propagation in a steel beam specimen, precracked in fatigue, in a four-point bending test.
NASA Astrophysics Data System (ADS)
Kikuchi, Yusuke; Maegawa, Takuya; Otsubo, Akira; Nishimura, Yoshimi; Nagata, Masayoshi; Yatsuzuka, Mitsuyasu
2018-05-01
Two discharge modes, α and γ, of a repetitive nanosecond pulsed helium glow discharge at a gas pressure of 10 kPa in the repetition frequency range from 20 to 600 kHz are reported for the first time. The pulsed glow discharge is produced in a pair of parallel plate metal electrodes without insertion of dielectrics. The α mode discharge is volumetrically produced in the electrode gap at a low-repetition frequency, whereas the γ mode discharge is localized at the cathode surface at a high-repetition frequency. At high-repetition frequency, the time interval between voltage pulses is shorter than the lifetime of the afterglow produced by the preceding discharge. Then, the γ mode discharge is maintained by a large number of secondary electrons emitted from the cathode exposed to high-density ions and metastable helium atoms in the afterglow. In the α mode discharge with a low-repetition frequency operation, primary electrons due to gas ionization dominate the ionization process. Thus, a large discharge voltage is needed for the excitation of the α mode discharge. It is established that the bifurcation of α-γ discharge mode, accompanied by a decrease in the discharge voltage, occurs at the high-repetition frequency of ∼120 kHz.
CMOS Optoelectronic Lock-In Amplifier With Integrated Phototransistor Array.
An Hu; Chodavarapu, Vamsy P
2010-10-01
We describe the design and development of an optoelectronic lock-in amplifier (LIA) for optical sensing and spectroscopy applications. The prototype amplifier is fabricated using Taiwan Semiconductor Manufacturing Co. complementary metal-oxide semiconductor 0.35-μm technology and uses a phototransistor array (total active area is 400 μm × 640μm) to convert the incident optical signals into electrical currents. The photocurrents are then converted into voltage signals using a transimpedance amplifier for subsequent convenient signal processing by the LIA circuitry. The LIA is optimized to be operational at 20-kHz modulation frequency but is operational in the frequency range from 13 kHz to 25 kHz. The system is tested with a light-emitting diode (LED) as the light source. The noise and signal distortions are suppressed with filters and a phase-locked loop (PLL) implemented in the LIA. The output dc voltage of the LIA is proportional to the incident optical power. The minimum measured dynamic reserve and sensitivity are 1.31 dB and 34 mV/μW, respectively. The output versus input relationship has shown good linearity. The LIA consumes an average power of 12.79 mW with a 3.3-V dc power supply.
200 kHz Commercial Sonar Systems Generate Lower Frequency Side Lobes Audible to Some Marine Mammals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deng, Zhiqun; Southall, Brandon; Carlson, Thomas J.
2014-04-15
The spectral properties of pulses transmitted by three commercially available 200 kHz echo sounders were measured to assess the possibility that sound energy in below the center (carrier) frequency might be heard by marine mammals. The study found that all three sounders generated sound at frequencies below the center frequency and within the hearing range of some marine mammals and that this sound was likely detectable by the animals over limited ranges. However, at standard operating source levels for the sounders, the sound below the center frequency was well below potentially harmful levels. It was concluded that the sounds generatedmore » by the sounders could affect the behavior of marine mammals within fairly close proximity to the sources and that that the blanket exclusion of echo sounders from environmental impact analysis based solely on the center frequency output in relation to the range of marine mammal hearing should be reconsidered.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, K.R.
1976-01-12
The Nads FSK Modem is a compact unit designed to operate in conjunction with EIA standard interfacing and the data terminal equipment of the 1200 Baud digital communications network of the Nevada Automated Diagnostics System (NADS). The modem is constructed in a Nuclear Instrumentation Module System (NIMS) module for compatability with the NADS system. The modulator section of the modem accepts serial, digital signals at 1200 Baud which may be either standard TTL levels or bipolar signals meeting either the EIA RS-232C or RS-232B standards. The output of the modulator is a Frequency-Shift Keyed (FSK) signal having frequencies of 2.2more » kHz for Mark and 1.2 kHz for Space. The demodulator section accepts the above FSK signal as input, and outputs serial, digital signals at 1200 Baud at either TTL or EIA RS-232C levels. Specifications and operation and calibration instructions are given. (WHK)« less
Gerbil middle-ear sound transmission from 100 Hz to 60 kHz1
Ravicz, Michael E.; Cooper, Nigel P.; Rosowski, John J.
2008-01-01
Middle-ear sound transmission was evaluated as the middle-ear transfer admittance HMY (the ratio of stapes velocity to ear-canal sound pressure near the umbo) in gerbils during closed-field sound stimulation at frequencies from 0.1 to 60 kHz, a range that spans the gerbil’s audiometric range. Similar measurements were performed in two laboratories. The HMY magnitude (a) increased with frequency below 1 kHz, (b) remained approximately constant with frequency from 5 to 35 kHz, and (c) decreased substantially from 35 to 50 kHz. The HMY phase increased linearly with frequency from 5 to 35 kHz, consistent with a 20–29 μs delay, and flattened at higher frequencies. Measurements from different directions showed that stapes motion is predominantly pistonlike except in a narrow frequency band around 10 kHz. Cochlear input impedance was estimated from HMY and previously-measured cochlear sound pressure. Results do not support the idea that the middle ear is a lossless matched transmission line. Results support the ideas that (1) middle-ear transmission is consistent with a mechanical transmission line or multiresonant network between 5 and 35 kHz and decreases at higher frequencies, (2) stapes motion is pistonlike over most of the gerbil auditory range, and (3) middle-ear transmission properties are a determinant of the audiogram. PMID:18646983
Selected Issues in DoD’s Radio Frequency Identification (RFID) Implementation
2006-04-01
Evaluation of human exposure to electromagnetic fields from devices operating in the frequency range 0 Hz to 10 GHz, used in Electronic...standard for human exposure to RF Signal, 3 kHz-300 GHz BS EN 50364 Limitation of human exposure to electromagnetic fields from devices operating in the...Management and DoD Explosives Safety Board, and DoDD 6055.9-STD, DoD Ammunition and Explosives Safety Standards. Exposure of people to electromagnetic
Plasma wave observations during ion gun experiments
NASA Astrophysics Data System (ADS)
Olsen, R. C.; Weddle, L. E.; Roeder, J. L.
1990-06-01
Experiments in charge control on the AF/NASA P78-2 (SCATHA) satellite were conducted with a plasma/ion source in the inner magnetosphere. These experiments were monitored with plasma wave instruments capable of high temporal and frequency resolution in the 0-6 kHz frequency range. Ion gun experiments revealed two distinct classes of behavior. Nonneutralized ion beam operation at 1 mA, 1kV resulted in arcing signatures (spiky in time, broad frequency range), coincident with induced satellite potentials of -600 to -900 V. This signature disappeared when the accelerating voltage was switched off or the beam was neutralized. The signal is attributed to arcing between differentially charged surfaces. An additional feature was noted in the 100-kHz channel of the wave receiver. During emission of dense, low-energy plasma, a signal is generated which may be at the upper hybrid, or plasma frequency for the local plasma.
Surface modification of lignocellulosic fibers using high-frequency ultrasound
Jayant B. Gadhe; Ram B. Gupta; Thomas Elder
2005-01-01
Enzymatic and chemical oxidation of fiber surfaces has been reported in the literature as a method for producing medium density fiberboards without using synthetic adhesives. This work focuses on modifying the surface properties of wood fibers by the generation of free radicals using high-frequency ultrasound. A sonochemical reactor operating at 610 kHz is used to...
Full-Sky Imaging at Low Frequencies
NASA Technical Reports Server (NTRS)
Jones, D. L.; Marsh, K.; Mahoney, M.; Kuiper, T.; Linfield, R.; Preston, R.; Unwin, S.; Shepherd, M.; Erickson, W.; Weiler, K.
1996-01-01
Exploring the frequency range from a few tens of MHZ down to a few tens of kHz commonly requires multiple antennas operating as an aperture synthesis interferometer to obtain angular resolution. This design must overcome the corrupting effects of interplanetary scintillation, interfering signals and nearly isotropic antennas that see strong sources such as the Sun and Jupiter at all times.
47 CFR 76.616 - Operation near certain aeronautical and marine emergency radio frequencies.
Code of Federal Regulations, 2012 CFR
2012-10-01
... (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Technical Standards § 76... of carriers or other signal components capable of delivering peak power levels equal to or greater than 10−5 watts at any point in a cable television system is prohibited within 100 kHz of the frequency...
47 CFR 76.616 - Operation near certain aeronautical and marine emergency radio frequencies.
Code of Federal Regulations, 2014 CFR
2014-10-01
... (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Technical Standards § 76... of carriers or other signal components capable of delivering peak power levels equal to or greater than 10−5 watts at any point in a cable television system is prohibited within 100 kHz of the frequency...
2008-09-30
adaptively using real-time data collected with the international constellation of ocean color satellites, a nested grid of HF radars, and an operational... gastropod were located during a 2-day period. These aggregations were remarkablystrong scatterers at frequencies ranging from 38-200 kHz. Data
Tavakkolizadeh, Moein; Love‐Jones, Sarah; Patel, Nikunj K.; Gu, Jianwen Wendy; Bains, Amarpreet; Doan, Que; Moffitt, Michael
2017-01-01
Objective The PROCO RCT is a multicenter, double‐blind, crossover, randomized controlled trial (RCT) that investigated the effects of rate on analgesia in kilohertz frequency (1–10 kHz) spinal cord stimulation (SCS). Materials and Methods Patients were implanted with SCS systems and underwent an eight‐week search to identify the best location (“sweet spot”) of stimulation at 10 kHz within the searched region (T8–T11). An electronic diary (e‐diary) prompted patients for pain scores three times per day. Patients who responded to 10 kHz per e‐diary numeric rating scale (ED‐NRS) pain scores proceeded to double‐blind rate randomization. Patients received 1, 4, 7, and 10 kHz SCS at the same sweet spot found for 10 kHz in randomized order (four weeks at each frequency). For each frequency, pulse width and amplitude were titrated to optimize therapy. Results All frequencies provided equivalent pain relief as measured by ED‐NRS (p ≤ 0.002). However, mean charge per second differed across frequencies, with 1 kHz SCS requiring 60–70% less charge than higher frequencies (p ≤ 0.0002). Conclusions The PROCO RCT provides Level I evidence for equivalent pain relief from 1 to 10 kHz with appropriate titration of pulse width and amplitude. 1 kHz required significantly less charge than higher frequencies. PMID:29220121
Moore, Brian C J; Ernst, Stephan M A
2012-09-01
It is commonly believed that difference limens for frequency (DLFs) for pure tones depend on a temporal mechanism (phase locking) for frequencies up to 4-5 kHz and a place mechanism at higher frequencies. The DLFs predicted from a place mechanism, expressed as a proportion of center frequency (Δf/f), should be approximately invariant with frequency at medium to high frequencies. If there is a transition from a temporal to a place mechanism, Δf/f should increase with increasing center frequency until the transition occurs, and then reach a plateau. Published data do not show such an effect. In this study, DLFs were measured for center frequencies from 2 to 14 kHz, using earphones designed to produce a flat response at the eardrum. The level of every tone was varied over a range of ±4 dB, to reduce loudness cues. The value of Δf/f increased progressively from 2 to 8 kHz, but did not change significantly for frequencies from 8 to 14 kHz. The results are consistent with the idea that there is a transition from a temporal to a place mechanism at about 8 kHz, rather than at 4-5 kHz, as is commonly assumed.
47 CFR 18.303 - Prohibited frequency bands.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Prohibited frequency bands. 18.303 Section 18.303 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL INDUSTRIAL, SCIENTIFIC, AND MEDICAL... following safety, search and rescue frequency bands is prohibited: 490-510 kHz, 2170-2194 kHz, 8354-8374 kHz...
47 CFR 18.303 - Prohibited frequency bands.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 1 2013-10-01 2013-10-01 false Prohibited frequency bands. 18.303 Section 18.303 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL INDUSTRIAL, SCIENTIFIC, AND MEDICAL... following safety, search and rescue frequency bands is prohibited: 490-510 kHz, 2170-2194 kHz, 8354-8374 kHz...
47 CFR 18.303 - Prohibited frequency bands.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Prohibited frequency bands. 18.303 Section 18.303 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL INDUSTRIAL, SCIENTIFIC, AND MEDICAL... following safety, search and rescue frequency bands is prohibited: 490-510 kHz, 2170-2194 kHz, 8354-8374 kHz...
47 CFR 18.303 - Prohibited frequency bands.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 1 2014-10-01 2014-10-01 false Prohibited frequency bands. 18.303 Section 18.303 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL INDUSTRIAL, SCIENTIFIC, AND MEDICAL... following safety, search and rescue frequency bands is prohibited: 490-510 kHz, 2170-2194 kHz, 8354-8374 kHz...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deng, Zhiqun; Carlson, Thomas J.; Xu, Jinshan
2011-09-30
Before final approval is given to the Snohomish County Public Utility District No. 1 for deploying the first tidal power devices in the United States in an open water environment, a system to manage the potential risk of injury to killer whales due to collision with moving turbine blades must be demonstrated. The Pacific Northwest National Laboratory (PNNL) is tasked with establishing the performance requirements for, constructing, and testing a prototype marine animal alert system for triggering temporary turbine shutdown when there is risk of collision with a killer whale. To develop a system that relies on active sonar twomore » critical areas must be investigated - the target strength of killer whales and the frequency content of commercially available active sonar units. PNNL studied three target strength models: a simple model, the Fourier matching model, and the Kirchoff-ray mode model. Using target strength measurements of bottlenose dolphins obtained by previous researchers and assuming killer whales share similar morphology and structure, PNNL extrapolated the target strength of an adult killer whale 7.5 m in length at a frequency of 67 kHz. To study the frequency content of a commercially available sonar unit, direct measurements of the signal transmitted by the sonar were obtained by using a hydrophone connected to a data acquisition system in both laboratory and field conditions. The measurements revealed that in addition to the primary frequency of 200 kHz, there is a secondary frequency component at 90 kHz, which is within the hearing range of killer whales. The amplitude of the 90-kHz frequency component is above the hearing threshold of killer whales but below the threshold for potential injuries.« less
Asynchronous inputs alter excitability, spike timing, and topography in primary auditory cortex
Pandya, Pritesh K.; Moucha, Raluca; Engineer, Navzer D.; Rathbun, Daniel L.; Vazquez, Jessica; Kilgard, Michael P.
2010-01-01
Correlation-based synaptic plasticity provides a potential cellular mechanism for learning and memory. Studies in the visual and somatosensory systems have shown that behavioral and surgical manipulation of sensory inputs leads to changes in cortical organization that are consistent with the operation of these learning rules. In this study, we examine how the organization of primary auditory cortex (A1) is altered by tones designed to decrease the average input correlation across the frequency map. After one month of separately pairing nucleus basalis stimulation with 2 and 14 kHz tones, a greater proportion of A1 neurons responded to frequencies below 2 kHz and above 14 kHz. Despite the expanded representation of these tones, cortical excitability was specifically reduced in the high and low frequency regions of A1, as evidenced by increased neural thresholds and decreased response strength. In contrast, in the frequency region between the two paired tones, driven rates were unaffected and spontaneous firing rate was increased. Neural response latencies were increased across the frequency map when nucleus basalis stimulation was associated with asynchronous activation of the high and low frequency regions of A1. This set of changes did not occur when pulsed noise bursts were paired with nucleus basalis stimulation. These results are consistent with earlier observations that sensory input statistics can shape cortical map organization and spike timing. PMID:15855025
Tsai, Tsung-Han; Zhou, Chao; Adler, Desmond C; Fujimoto, James G
2009-11-09
We demonstrate a frequency comb (FC) swept laser and a frequency comb Fourier domain mode locked (FC-FDML) laser for applications in optical coherence tomography (OCT). The fiber-based FC swept lasers operate at a sweep rate of 1kHz and 120kHz, respectively over a 135nm tuning range centered at 1310nm with average output powers of 50mW. A 25GHz free spectral range frequency comb filter in the swept lasers causes the lasers to generate a series of well defined frequency steps. The narrow bandwidth (0.015nm) of the frequency comb filter enables a approximately -1.2dB sensitivity roll off over approximately 3mm range, compared to conventional swept source and FDML lasers which have -10dB and -5dB roll offs, respectively. Measurements at very long ranges are possible with minimal sensitivity loss, however reflections from outside the principal measurement range of 0-3mm appear aliased back into the principal range. In addition, the frequency comb output from the lasers are equally spaced in frequency (linear in k-space). The filtered laser output can be used to self-clock the OCT interference signal sampling, enabling direct fast Fourier transformation of the fringe signals, without the need for fringe recalibration procedures. The design and operation principles of FC swept lasers are discussed and designs for short cavity lasers for OCT and interferometric measurement applications are proposed.
Tsai, Tsung-Han; Zhou, Chao; Adler, Desmond C.; Fujimoto, James G.
2010-01-01
We demonstrate a frequency comb (FC) swept laser and a frequency comb Fourier domain mode locked (FC-FDML) laser for applications in optical coherence tomography (OCT). The fiber-based FC swept lasers operate at a sweep rate of 1kHz and 120kHz, respectively over a 135nm tuning range centered at 1310nm with average output powers of 50mW. A 25GHz free spectral range frequency comb filter in the swept lasers causes the lasers to generate a series of well defined frequency steps. The narrow bandwidth (0.015nm) of the frequency comb filter enables a ~−1.2dB sensitivity roll off over ~3mm range, compared to conventional swept source and FDML lasers which have −10dB and −5dB roll offs, respectively. Measurements at very long ranges are possible with minimal sensitivity loss, however reflections from outside the principal measurement range of 0–3mm appear aliased back into the principal range. In addition, the frequency comb output from the lasers are equally spaced in frequency (linear in k-space). The filtered laser output can be used to self-clock the OCT interference signal sampling, enabling direct fast Fourier transformation of the fringe signals, without the need for fringe recalibration procedures. The design and operation principles of FC swept lasers are discussed and designs for short cavity lasers for OCT and interferometric measurement applications are proposed. PMID:19997365
Moore, Brian C J; Stone, Michael A; Füllgrabe, Christian; Glasberg, Brian R; Puria, Sunil
2008-12-01
It is possible for auditory prostheses to provide amplification for frequencies above 6 kHz. However, most current hearing-aid fitting procedures do not give recommended gains for such high frequencies. This study was intended to provide information that could be useful in quantifying appropriate high-frequency gains, and in establishing the population of hearing-impaired people who might benefit from such amplification. The study had two parts. In the first part, wide-bandwidth recordings of normal conversational speech were obtained from a sample of male and female talkers. The recordings were used to determine the mean spectral shape over a wide frequency range, and to determine the distribution of levels (the speech dynamic range) as a function of center frequency. In the second part, audiometric thresholds were measured for frequencies of 0.125, 0.25, 0.5, 1, 2, 3, 4, 6, 8, 10, and 12.5 kHz for both ears of 31 people selected to have mild or moderate cochlear hearing loss. The hearing loss was never greater than 70 dB for any frequency up to 4 kHz. The mean spectrum level of the speech fell progressively with increasing center frequency above about 0.5 kHz. For speech with an overall level of 65 dB SPL, the mean 1/3-octave level was 49 and 37 dB SPL for center frequencies of 1 and 10 kHz, respectively. The dynamic range of the speech was similar for center frequencies of 1 and 10 kHz. The part of the dynamic range below the root-mean-square level was larger than reported in previous studies. The mean audiometric thresholds at high frequencies (10 and 12.5 kHz) were relatively high (69 and 77 dB HL, respectively), even though the mean thresholds for frequencies below 4 kHz were 41 dB HL or better. To partially restore audibility for a hearing loss of 65 dB at 10 kHz would require an effective insertion gain of about 36 dB at 10 kHz. With this gain, audibility could be (partly) restored for 25 of the 62 ears assessed.
NASA Astrophysics Data System (ADS)
Shcherbakov, Alexandre S.; Chavez Dagostino, Miguel; Arellanes, Adan O.; Aguirre Lopez, Arturo
2016-09-01
We develop a multi-band spectrometer with a few spatially parallel optical arms for the combined processing of their data flow. Such multi-band capability has various applications in astrophysical scenarios at different scales: from objects in the distant universe to planetary atmospheres in the Solar system. Each optical arm exhibits original performances to provide parallel multi-band observations with different scales simultaneously. Similar possibility is based on designing each optical arm individually via exploiting different materials for acousto-optical cells operating within various regimes, frequency ranges and light wavelengths from independent light sources. Individual beam shapers provide both the needed incident light polarization and the required apodization to increase the dynamic range of a system. After parallel acousto-optical processing, data flows are united by the joint CCD matrix on the stage of the combined electronic data processing. At the moment, the prototype combines still three bands, i.e. includes three spatial optical arms. The first low-frequency arm operates at the central frequencies 60-80 MHz with frequency bandwidth 40 MHz. The second arm is oriented to middle-frequencies 350-500 MHz with frequency bandwidth 200-300 MHz. The third arm is intended for ultra-high-frequency radio-wave signals about 1.0-1.5 GHz with frequency bandwidth <300 MHz. To-day, this spectrometer has the following preliminary performances. The first arm exhibits frequency resolution 20 KHz; while the second and third arms give the resolution 150-200 KHz. The numbers of resolvable spots are 1500- 2000 depending on the regime of operation. The fourth optical arm at the frequency range 3.5 GHz is currently under construction.
47 CFR 90.242 - Travelers' information stations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... the modulation limiter and the modulated stage. At audio frequencies between 3 kHz and 20 kHz this...' information stations. (a) The frequencies 530 through 1700 kHz in 10 kHz increments may be assigned to the... consideration of possible cross-modulation and inter-modulation interference effects which may result from the...
Audiogram of a striped dolphin (Stenella coeruleoalba)
NASA Astrophysics Data System (ADS)
Kastelein, Ronald A.; Hagedoorn, Monique; Au, Whitlow W. L.; de Haan, Dick
2003-02-01
The underwater hearing sensitivity of a striped dolphin was measured in a pool using standard psycho-acoustic techniques. The go/no-go response paradigm and up-down staircase psychometric method were used. Auditory sensitivity was measured by using 12 narrow-band frequency-modulated signals having center frequencies between 0.5 and 160 kHz. The 50% detection threshold was determined for each frequency. The resulting audiogram for this animal was U-shaped, with hearing capabilities from 0.5 to 160 kHz (8
The RF spectra of first and subsequent lightning return strokes in the 1- to 200-km range
NASA Technical Reports Server (NTRS)
Serhan, G. I.; Uman, M. A.; Childers, D. G.; Lin, Y. T.
1980-01-01
An experimental characterization of the frequency spectra of first and subsequent stroke electric fields are presented over a distance range from about 1 km, where the fields are primarily electrostatic, to 200 km, where they are primarily radiation. Spectra are presented to about 700 kHz for lightning within 12 km and to about 300 kHz for lightning at 50 and 200 km. It is shown that the return stroke ground wave spectrum beyond 50 km has a peak near 4 kHz but that within 10 km the spectrum shows a steady increase with decreasing frequency to 1 kHz. Frequency spectra at all ranges fall off roughly as 1/f for frequencies between 5 and 100 kHz, while the falloff above 100 kHz is faster as the distance to the stroke increases. From this high-frequency attenuation an RF conductivity for central Florida of between 0.002 and 0.005/ohm/m was determined.
High power density dc-to-dc converters for aerospace applications
NASA Technical Reports Server (NTRS)
Divan, Deepakraj M.
1990-01-01
Three dc-to-dc converter topologies aimed at high-power high-frequency applications are introduced. Major system parasitics, namely, the leakage inductance of the transformer and the device output capacitance are efficiently utilized. Of the three circuits, the single-phase and three-phase versions of the dual active bridge topology demonstrate minimal stresses, better utilization of the transformer, bidirectional, and buck-boost modes of operation. All circuits operate at a constant switching frequency, thus simplifying design of the reactive elements. The power transfer characteristics and soft-switching regions on the Vout-Iout plane are identified. Two coaxial transformers with different cross-sections were built for a rating of 50 kVA. Based on the single-phase dual active bridge topology, a 50 kW, 50 kHz converter operating at an input voltage of 200 Vdc and an output voltage of 1600 Vdc was fabricated. Characteristics of current-fed output make the dual active bridge topologies amenable to paralleling and hence extension to megawatt power levels. Projections to a 1 MW system operating from a 500 Vdc input, at an output voltage of 10 kVdc and a switching frequency of 50 kHz, using MOS-controlled thyristors, coaxially wound transformers operating at three times the present current density with cooling, and multilayer ceramic capacitors, suggests an overall power density of 0.075 to 0.08 kg/kW and an overall efficiency of 96 percent.
Noninvasive transcranial stimulation of rat abducens nerve by focused ultrasound.
Kim, Hyungmin; Taghados, Seyed Javid; Fischer, Krisztina; Maeng, Lee-So; Park, Shinsuk; Yoo, Seung-Schik
2012-09-01
Nonpharmacologic and nonsurgical transcranial modulation of the nerve function may provide new opportunities in evaluation and treatment of cranial nerve diseases. This study investigates the possibility of using low-intensity transcranial focused ultrasound (FUS) to selectively stimulate the rat abducens nerve located above the base of the skull. FUS (frequencies of 350 kHz and 650 kHz) operating in a pulsed mode was applied to the abducens nerve of Sprague-Dawley rats under stereotactic guidance. The abductive eyeball movement ipsilateral to the side of sonication was observed at 350 kHz, using the 0.36-msec tone burst duration (TBD), 1.5-kHz pulse repetition frequency (PRF), and the overall sonication duration of 200 msec. Histologic and behavioral monitoring showed no signs of disruption in the blood brain barrier (BBB), as well as no damage to the nerves and adjacent brain tissue resulting from the sonication. As a novel functional neuro-modulatory modality, the pulsed application of FUS has potential for diagnostic and therapeutic applications in diseases of the peripheral nervous system. Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Noise effect on performance of IR PVDF pyroelectric detector
NASA Astrophysics Data System (ADS)
Abdullah, K. Al; Batal, M. Anwar; Hamdan, Rawad; Khalil, Toni; Salame, Chafic
2018-05-01
The spin-casting and casting technology were used to make IR pyroelectric PVDF detectors, where the operational amplifier, TC75S63TU, is used to amplify pyroelectrical signal. The pyroelectric coefficient is measured by charge integration method, which is 23 µC/m2K. The voltage responsivity and noise equivalent power depending on the dielectric constant, specific conductivity and loss tangent, which are measured at various frequencies, is estimated where changing of detector capacitance and resistor with frequency is taken into account. Maximum voltage responsivity was for detector thickness d=116.05 µm at chopping frequency (f=0.8Hz). Influence of thermal, Johnson and amplifier noises on output voltage are studied. At frequencies (<1kHz), Johnson noise dominates whereas at frequencies (>1kHz), amplifier voltage noise dominates. The thinner detector, the lower noise affects on output voltage. The optimal signal to noise ratio (SNR) of pyroelectrical detector is for thickness d=30.1 µm at frequency f=20Hz. The reducing electrode area decreases slightly total noise at low frequency and enhances slightly SNR of pyroelectrical detector.
Linewidth and tuning characteristics of terahertz quantum cascade lasers.
Barkan, A; Tittel, F K; Mittleman, D M; Dengler, R; Siegel, P H; Scalari, G; Ajili, L; Faist, J; Beere, H E; Linfield, E H; Davies, A G; Ritchie, D A
2004-03-15
We have measured the spectral linewidths of three continuous-wave quantum cascade lasers operating at terahertz frequencies by heterodyning the free-running quantum cascade laser with two far-infrared gas lasers. Beat notes are detected with a GaAs diode mixer and a microwave spectrum analyzer, permitting very precise frequency measurements and giving instantaneous linewidths of less than -30 kHz. Characteristics are also reported for frequency tuning as the injection current is varied.
Optimizing Clinical Interpretation of Distortion Product Otoacoustic Emissions in Infants.
Blankenship, Chelsea M; Hunter, Lisa L; Keefe, Douglas H; Feeney, M Patrick; Brown, David K; McCune, Annie; Fitzpatrick, Denis F; Lin, Li
2018-03-06
The purpose of this study was to analyze distortion product otoacoustic emission (DPOAE) level and signal to noise ratio in a group of infants from birth to 4 months of age to optimize prediction of hearing status. DPOAEs from infants with normal hearing (NH) and hearing loss (HL) were used to predict the presence of conductive HL (CHL), sensorineural HL (SNHL), and mixed HL (MHL). Wideband ambient absorbance was also measured and compared among the HL types. This is a prospective, longitudinal study of 279 infants with verified NH and HL, including conductive, sensorineural, and mixed types that were enrolled from a well-baby nursery and two neonatal intensive care units in Cincinnati, Ohio. At approximately 1 month of age, DPOAEs (1-8 kHz), wideband absorbance (0.25-8 kHz), and air and bone conduction diagnostic tone burst auditory brainstem response (0.5-4 kHz) thresholds were measured. Hearing status was verified at approximately 9 months of age with visual reinforcement audiometry (0.5-4 kHz). Auditory brainstem response air conduction thresholds were used to assign infants to an NH or HL group, and the efficacy of DPOAE data to classify ears as NH or HL was analyzed using receiver operating characteristic (ROC) curves. Two summary statistics of the ROC curve were calculated: the area under the ROC curve and the point of symmetry on the curve at which the sensitivity and specificity were equal. DPOAE level and signal to noise ratio cutoff values were defined at each frequency as the symmetry point on their respective ROC curve, and DPOAE results were combined across frequency in a multifrequency analysis to predict the presence of HL. Single-frequency test performance of DPOAEs was best at mid to high frequencies (3-8 kHz) with intermediate performance at 1.5 and 2 kHz and chance performance at 1 kHz. Infants with a conductive component to their HL (CHL and MHL combined) displayed significantly lower ambient absorbance values than the NH group. No differences in ambient absorbance were found between the NH and SNHL groups. Multifrequency analysis resulted in the best prediction of HL for the SNHL/MHL group with poorer sensitivity values when infants with CHL were included. Clinical interpretation of DPOAEs in infants can be improved by using age-appropriate normative ranges and optimized cutoff values. DPOAE interpretation is most predictive at higher F2 test frequencies in young infants (2-8 kHz) due to poor test performance at 1 to 1.5 kHz. Multifrequency rules can be used to improve sensitivity while balancing specificity. Last, a sensitive middle ear measure such as wideband absorbance should be included in the test battery to assess possibility of a conductive component to the HL.
The Design and Characterization of a Prototype Wideband Voltage Sensor Based on a Resistive Divider
Garnacho, Fernando; Khamlichi, Abderrahim; Rovira, Jorge
2017-01-01
The most important advantage of voltage dividers over traditional voltage transformers is that voltage dividers do not have an iron core with non-linear hysteresis characteristics. The voltage dividers have a linear behavior with respect to over-voltages and a flat frequency response larger frequency range. The weak point of a voltage divider is the influence of external high-voltage (HV) and earth parts in its vicinity. Electrical fields arising from high voltages in neighboring phases and from ground conductors and structures are one of their main sources for systematic measurement errors. This paper describes a shielding voltage divider for a 24 kV medium voltage network insulated in SF6 composed of two resistive-capacitive dividers, one integrated within the other, achieving a flat frequency response up to 10 kHz for ratio error and up to 5 kHz for phase displacement error. The metal shielding improves its immunity against electric and magnetic fields. The characterization performed on the built-in voltage sensor shows an accuracy class of 0.2 for a frequency range from 20 Hz to 5 kHz and a class of 0.5 for 1 Hz up to 20 Hz. A low temperature effect is also achieved for operation conditions of MV power grids. PMID:29149085
The Design and Characterization of a Prototype Wideband Voltage Sensor Based on a Resistive Divider.
Garnacho, Fernando; Khamlichi, Abderrahim; Rovira, Jorge
2017-11-17
The most important advantage of voltage dividers over traditional voltage transformers is that voltage dividers do not have an iron core with non-linear hysteresis characteristics. The voltage dividers have a linear behavior with respect to over-voltages and a flat frequency response larger frequency range. The weak point of a voltage divider is the influence of external high-voltage (HV) and earth parts in its vicinity. Electrical fields arising from high voltages in neighboring phases and from ground conductors and structures are one of their main sources for systematic measurement errors. This paper describes a shielding voltage divider for a 24 kV medium voltage network insulated in SF6 composed of two resistive-capacitive dividers, one integrated within the other, achieving a flat frequency response up to 10 kHz for ratio error and up to 5 kHz for phase displacement error. The metal shielding improves its immunity against electric and magnetic fields. The characterization performed on the built-in voltage sensor shows an accuracy class of 0.2 for a frequency range from 20 Hz to 5 kHz and a class of 0.5 for 1 Hz up to 20 Hz. A low temperature effect is also achieved for operation conditions of MV power grids.
Compact atmospheric pressure plasma self-resonant drive circuits
NASA Astrophysics Data System (ADS)
Law, V. J.; Anghel, S. D.
2012-02-01
This paper reports on compact solid-state self-resonant drive circuits that are specifically designed to drive an atmospheric pressure plasma jet and a parallel-plate dielectric barrier discharge of small volume (0.5 cm3). The atmospheric pressure plasma (APP) device can be operated with helium, argon or a mixture of both. Equivalent electrical models of the self-resonant drive circuits and discharge are developed and used to estimate the plasma impedance, plasma power density, current density or electron number density of three APP devices. These parameters and the kinetic gas temperature are dependent on the self-resonant frequency of the APP device. For a fixed switching frequency and APP device geometry, the plasma parameters are controlled by adjusting the dc voltage at the primary coil and the gas flow rate. The resonant frequency is controlled by the selection of the switching power transistor and means of step-up voltage transformation (ferrite core, flyback transformer, or Tesla coil). The flyback transformer operates in the tens of kHz, the ferrite core in the hundreds of kHz and Tesla coil in the MHz range. Embedded within this work is the principle of frequency pulling which is exemplified in the flyback transformer circuit that utilizes a pickup coil for feedback control of the switching frequency.
47 CFR 95.857 - Emission standards.
Code of Federal Regulations, 2010 CFR
2010-10-01
... frequency as close to the edge of the authorized frequency segment as the transmitter is designed to be... power shall be 100 Hz for measuring emissions up to and including 250 kHz from the edge of the authorized frequency segment, and 10 kHz for measuring emissions more than 250 kHz from the edge of the...
Plasma Oscillation Characterization of NASA's HERMeS Hall Thruster via High Speed Imaging
NASA Technical Reports Server (NTRS)
Huang, Wensheng; Kamhawi, Hani; Haag, Thomas W.
2016-01-01
The performance and facility effect characterization tests of NASA's 12.5-kW Hall Effect Rocket with Magnetic Shielding had been completed. As a part of these tests, three plasma oscillation characterization studies were performed to help determine operation settings and quantify margins. The studies included the magnetic field strength variation study, background pressure effect study, and cathode flow fraction study. Separate high-speed videos of the thruster including the cathode and of only the cathode were recorded. Breathing mode at 10-15 kHz and cathode gradient-driven mode at 60-75 kHz were observed. An additional high frequency (40-70 kHz) global oscillation mode with sinusoidal probability distribution function was identified.
47 CFR 15.109 - Radiated emission limits.
Code of Federal Regulations, 2011 CFR
2011-10-01
... of 9 kHz to 30 MHz, including devices that deliver the radio frequency energy to transducers, such as... for intentional radiators provided in § 15.209 for the frequency range of 9 kHz to 30 MHz. As an... 525 kHz to 1705 kHz may comply with the radiated emission limits provided in § 15.221(a). At...
47 CFR 15.109 - Radiated emission limits.
Code of Federal Regulations, 2014 CFR
2014-10-01
... of 9 kHz to 30 MHz, including devices that deliver the radio frequency energy to transducers, such as... for intentional radiators provided in § 15.209 for the frequency range of 9 kHz to 30 MHz. As an... 525 kHz to 1705 kHz may comply with the radiated emission limits provided in § 15.221(a). At...
47 CFR 15.109 - Radiated emission limits.
Code of Federal Regulations, 2013 CFR
2013-10-01
... of 9 kHz to 30 MHz, including devices that deliver the radio frequency energy to transducers, such as... for intentional radiators provided in § 15.209 for the frequency range of 9 kHz to 30 MHz. As an... 525 kHz to 1705 kHz may comply with the radiated emission limits provided in § 15.221(a). At...
47 CFR 15.109 - Radiated emission limits.
Code of Federal Regulations, 2012 CFR
2012-10-01
... of 9 kHz to 30 MHz, including devices that deliver the radio frequency energy to transducers, such as... for intentional radiators provided in § 15.209 for the frequency range of 9 kHz to 30 MHz. As an... 525 kHz to 1705 kHz may comply with the radiated emission limits provided in § 15.221(a). At...
The 77 K operation of a multi-resonant power converter
NASA Technical Reports Server (NTRS)
Ray, Biswajit; Gerber, Scott S.; Patterson, Richard L.; Myers, Ira T.
1995-01-01
The liquid-nitrogen temperature (77 K) operation of a 55 W, 200 kHz, 48/28 V zero-voltage switching multi-resonant dc/dc converter designed with commercially available components is reported. Upon dipping the complete converter (power and control circuits) into liquid-nitrogen, the converter performance improved as compared to the room-temperature operation. The switching frequency, resonant frequency, and the characteristic impedance did not change significantly. Accordingly, the zero-voltage switching was maintained from no-load to full-load for the specified line variations. Cryoelectronics can provide high density power converters, especially for high power applications.
[Echolocation calls of free-flying Himalayan swiftlets (Aerodramus brevirostris)].
Wang, Bin; Ma, Jian-Zhang; Chen, Yi; Tan, Liang-Jing; Liu, Qi; Shen, Qi-Qi; Liao, Qing-Yi; Zhang, Li-Biao
2013-02-01
Here, we present our findings of free-flying echolocation calls of Himalayan swiftlets (Aerodramus brevirostris), which were recorded in Shenjing Cave, Hupingshan National Reserve, Shimen County, Hunan Province in June 2012, using Avisoft-UltraSoundGate 116(e). We noted that after foraging at dusk, the Himalayan swiftlets flew fast into the cave without clicks, and then slowed down in dark area in the cave, but with sounds. The echolocation sounds of Himalayan swiftlets are broadband, double noise burst clicks, separated by a short pause. The inter-pulse intervals between double clicks (99.3±3.86 ms)were longer than those within double clicks (6.6±0.42 ms) (P<0.01). With the exception of peak frequency, between 6.2±0.08 kHz and 6.2±0.10 kHz, (P>0.05) and pulse duration 2.9±0.12 ms, 3.2±0.17 ms, (P>0.05) between the first and second, other factors-maximum frequency, minimum frequency, frequency bandwidth, and power-were significantly different between the clicks. The maximum frequency of the first pulse (20.1±1.10 kHz) was higher than that of second (15.4±0.98 kHz) (P<0.01), while the minimum frequency of the first pulse (3.7±0.12 kHz) was lower than that of second (4.0±0.09 kHz) (P<0.05); resulting in the frequency bandwidth of the first pulse (16.5±1.17 kHz) longer than that of second (11.4±1.01 kHz) (P<0.01). The power of the first pulse (-32.5±0.60 dB) was higher than that of second (-35.2±0.94 dB) (P<0.05). More importantly, we found that Himalayan swiftlets emitted echolocation pulses including ultrasonic sound, with a maximum frequency reaching 33.2 kHz.
Acoustic leak-detection system for railroad transportation security
NASA Astrophysics Data System (ADS)
Womble, P. C.; Spadaro, J.; Harrison, M. A.; Barzilov, A.; Harper, D.; Hopper, L.; Houchins, E.; Lemoff, B.; Martin, R.; McGrath, C.; Moore, R.; Novikov, I.; Paschal, J.; Rogers, S.
2007-04-01
Pressurized rail tank cars transport large volumes of volatile liquids and gases throughout the country, much of which is hazardous and/or flammable. These gases, once released in the atmosphere, can wreak havoc with the environment and local populations. We developed a system which can non-intrusively and non-invasively detect and locate pinhole-sized leaks in pressurized rail tank cars using acoustic sensors. The sound waves from a leak are produced by turbulence from the gas leaking to the atmosphere. For example, a 500 μm hole in an air tank pressurized to 689 kPa produces a broad audio frequency spectrum with a peak near 40 kHz. This signal is detectable at 10 meters with a sound pressure level of 25 dB. We are able to locate a leak source using triangulation techniques. The prototype of the system consists of a network of acoustic sensors and is located approximately 10 meters from the center of the rail-line. The prototype has two types of acoustic sensors, each with different narrow frequency response band: 40 kHz and 80 kHz. The prototype is connected to the Internet using WiFi (802.11g) transceiver and can be remotely operated from anywhere in the world. The paper discusses the construction, operation and performance of the system.
NASA Astrophysics Data System (ADS)
Browell, E. V.; Dobler, J. T.; Kooi, S. A.; Fenn, M. A.; Choi, Y.; Vay, S. A.; Harrison, F. W.; Moore, B.
2011-12-01
This paper discusses the latest flight test results of a multi-frequency intensity-modulated (IM) continuous-wave (CW) laser absorption spectrometer (LAS) that operates near 1.57 μm for remote CO2 column measurements. This IM-LAS system is under development for a future space-based mission to determine the global distribution of regional-scale CO2 sources and sinks, which is the objective of the NASA Active Sensing of CO2 Emissions during Nights, Days, and Seasons (ASCENDS) mission. A prototype of the ASCENDS system, called the Multi-frequency Fiber Laser Lidar (MFLL), has been flight tested in eleven airborne campaigns since May 2005. This paper compares the most recent results obtained during the 2010 and 2011 UC-12 and DC-8 flight tests, where MFLL remote CO2 column measurements were evaluated against airborne in situ CO2 profile measurements traceable to World Meteorological Organization standards. The major change to the MFLL system in 2011 was the implementation of several different IM modes, which could be quickly changed in flight, to directly compare the precision and accuracy of MFLL CO2 measurements in each mode. The different IM modes that were evaluated included "fixed" IM frequencies near 50, 200, and 500 kHz; frequencies changed in short time steps (Stepped); continuously swept frequencies (Swept); and a pseudo noise (PN) code. The Stepped, Swept, and PN modes were generated to evaluate the ability of these IM modes to desensitize MFLL CO2 column measurements to intervening optically thin aerosols/clouds. MFLL was flown on the NASA Langley UC-12 aircraft in May 2011 to evaluate the newly implemented IM modes and their impact on CO2 measurement precision and accuracy, and to determine which IM mode provided the greatest thin cloud rejection (TCR) for the CO2 column measurements. Within the current hardware limitations of the MFLL system, the "fixed" 50 kHz results produced similar SNR values to those found previously. The SNR decreased as expected with increasing IM frequency with the SNR(500 kHz) equal to 31% of SNR(50 kHz). The absolute accuracy of the 50 kHz CO2 measurement showed a previously observed altitude-dependent trend that was greatly reduced at 200 kHz. Laboratory experiments have duplicated this effect which results mainly from IM frequency cross talk between LAS wavelengths in the erbium-doped fiber amplifier (EDFA) and which is reduced when operating at higher IM frequencies. Performance of the Stepped, Swept, and PN modes were evaluated in close time proximity to each other, and these results will be discussed in this paper. A second series of ASCENDS flight tests were conducted on the NASA DC-8 from 25 July to 12 August 2011 over similar local land and ocean targets as in 2010 and with additional long-range flights planned over the corn fields of Iowa, forests in northern Wisconsin, and ice fields of southeastern Alaska. MFLL CO2 measurement results from this field campaign will also be presented.
High-frequency strontium vapor laser for biomedical applications
NASA Astrophysics Data System (ADS)
Hvorostovsky, A.; Kolmakov, E.; Kudashev, I.; Redka, D.; Kancer, A.; Kustikova, M.; Bykovskaya, E.; Mayurova, A.; Stupnikov, A.; Ruzankina, J.; Tsvetkov, K.; Lukyanov, N.; Paklinov, N.
2018-02-01
Sr-laser with high pulse repetition rate and high peak radiation power is a unique tool for studying rapidly occurring processes in time (plasma diagnostics, photoablation, etc.). In addition, the study of the frequency characteristics of the active medium of the laser helps to reveal the physics of the formation of an inverse medium in metal vapor lasers. In this paper, an experimental study of an Sr-laser with an active volume of 5.8 cm3 in the pulse repetition frequency range from 25 to 200 kHz is carried out, and a comparison with the frequency characteristics of media with large active volumes is given. We considered the frequency characteristics of the active medium in two modes: at a constant energy in the excitation pulse CU2 / 2 and at a constant average power consumed by the rectifier. In the presented work with a small-volume GRT using the TASITR-5/12 TASITRON switch, a laser was generated for Pairs of strontium at a CSF of 200 kHz. The behavior of the characteristics of the generation lines of 6.456 μm, 1 μm, and 3 μm at increased repetition frequencies is considered. Using the example of large-volume GRT, it is shown that tubes with a large active volume increase their energy characteristics with the growth of the CSF. The possibility of laser operation at pulse repetition rates above 200 kHz is shown.
Wideband profiles of stimulus-frequency otoacoustic emissions in humans
NASA Astrophysics Data System (ADS)
Dewey, James B.; Dhar, Sumitrajit
2015-12-01
Behavioral pure-tone hearing thresholds and stimulus-frequency otoacoustic emissions (SFOAEs) were measured with a high frequency resolution from 0.5-20 kHz in 15 female participants. Stimuli were calibrated in terms of forward pressure level (FPL). SFOAE responses to 36 dB FPL probes were largest near 1 kHz and declined above 8-10 kHz, though were still measurable at frequencies approaching 16 kHz in some ears. SFOAEs typically dropped in amplitude at a frequency that was roughly one octave below the "corner" frequency of the audiogram, and one-third to one-half of an octave below the frequency where thresholds departed from highly sensitive hearing. High-frequency SFOAE responses are likely limited by a reduction in the efficiency of the underlying generation mechanism and/or a diminished region of generation as the stimulus-driven excitation approaches the basal-most portion of the cochlea.
Sound pressure distribution and power flow within the gerbil ear canal from 100 Hz to 80 kHz
Ravicz, Michael E.; Olson, Elizabeth S.; Rosowski, John J.
2008-01-01
Sound pressure was mapped in the bony ear canal of gerbils during closed-field sound stimulation at frequencies from 0.1 to 80 kHz. A 1.27-mm-diam probe-tube microphone or a 0.17-mm-diam fiber-optic miniature microphone was positioned along approximately longitudinal trajectories within the 2.3-mm-diam ear canal. Substantial spatial variations in sound pressure, sharp minima in magnitude, and half-cycle phase changes occurred at frequencies >30 kHz. The sound frequencies of these transitions increased with decreasing distance from the tympanic membrane (TM). Sound pressure measured orthogonally across the surface of the TM showed only small variations at frequencies below 60 kHz. Hence, the ear canal sound field can be described fairly well as a one-dimensional standing wave pattern. Ear-canal power reflectance estimated from longitudinal spatial variations was roughly constant at 0.2–0.5 at frequencies between 30 and 45 kHz. In contrast, reflectance increased at higher frequencies to at least 0.8 above 60 kHz. Sound pressure was also mapped in a microphone-terminated uniform tube—an “artificial ear.” Comparison with ear canal sound fields suggests that an artificial ear or “artificial cavity calibration” technique may underestimate the in situ sound pressure by 5–15 dB between 40 and 60 kHz. PMID:17902852
High Repetition Rate Pulsed 2-Micron Laser Transmitter for Coherent CO2 DIAL Measurement
NASA Technical Reports Server (NTRS)
Singh, Uprendra N.; Bai, Yingxin; Yu, Jirong; Petros, Mulugeta; Petzar, Paul J.; Trieu, Bo C.; Lee, Hyung
2009-01-01
A high repetition rate, highly efficient, Q-switched 2-micron laser system as the transmitter of a coherent differential absorption lidar for CO2 measurement has been developed at NASA Langley Research Center. Such a laser transmitter is a master-slave laser system. The master laser operates in a single frequency, either on-line or off-line of a selected CO2 absorption line. The slave laser is a Q-switched ring-cavity Ho:YLF laser which is pumped by a Tm:fiber laser. The repetition rate can be adjusted from a few hundred Hz to 10 kHz. The injection seeding success rate is from 99.4% to 99.95%. For 1 kHz operation, the output pulse energy is 5.5mJ with the pulse length of approximately 50 ns. The optical-to-optical efficiency is 39% when the pump power is 14.5W. The measured standard deviation of the laser frequency jitter is about 3 MHz.
Noise measurements for single and multiple operation of 50 kw wind turbine generators
NASA Technical Reports Server (NTRS)
Hubbard, H. H.; Shepherd, K. P.
1982-01-01
The noise characteristics of the U.S. Windpower Inc., 50 kw wind turbine generator were measured at various distances from 30 m to 1100 m and for a range of output power. The generated noise is affected by the aerodynamic wakes of the tower legs at frequencies below about 120 Hz and the blade trailing edge thickness at frequencies of about 2 kHz. Rope strakes and airfoil fairings on the legs did not result in substantial noise reductions. Sharpening the blade trailing edges near the tip was effective in reducing broad band noise near 2 kHz. For multiple machines the sound fields are superposed. A three-fold increase in number of machines (from 1 to 3) results in a predicted increase in he sound pressure level of about 5 dB. The detection threshold for 14 machines operating in a 13 - 20 mph wind is observed to be at approximately 1160 m in the downwind direction.
Underwater noise pollution in a coastal tropical environment.
Bittencourt, L; Carvalho, R R; Lailson-Brito, J; Azevedo, A F
2014-06-15
Underwater noise pollution has become a major concern in marine habitats. Guanabara Bay, southeastern Brazil, is an impacted area of economic importance with constant vessel traffic. One hundred acoustic recording sessions took place over ten locations. Sound sources operating within 1 km radius of each location were quantified during recordings. The highest mean sound pressure level near the surface was 111.56±9.0 dB re 1 μPa at the frequency band of 187 Hz. Above 15 kHz, the highest mean sound pressure level was 76.21±8.3 dB re 1 μPa at the frequency 15.89 kHz. Noise levels correlated with number of operating vessels and vessel traffic composition influenced noise profiles. Shipping locations had the highest noise levels, while small vessels locations had the lowest noise levels. Guanabara Bay showed noise pollution similar to that of other impacted coastal regions, which is related to shipping and vessel traffic. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Stephen, Christopher; Kumaraswamy, S.
2018-01-01
An experimental investigation of the cavitation behaviour of a radial flow pump of metric specific speed 23.62 rpm having different leading edge profiles of the vane is presented. The pump was operated for flow rates from 80 to 120% of the best efficiency point. The measurement included noise and vibration signals apart from the hydraulic parameters. The results exhibited the trends of noise and vibration with respect to percentage of head drops for all operating conditions. It was concluded that the trends were totally different for various flow rates. Hence it is suggested that the criteria to be used for detecting the early cavitation in pump based on noise and vibration signals should be a function of the flow rate. Further, it was found that the range of frequency band for noise and vibration was within 5 kHz with reference to the magnitude of fluctuation. The repeatable predominant frequency of vibration for prediction of cavitation behaviour of this particular pump was established as 0.992 kHz.
Delmas, Henri; Le, Ngoc Tuan; Barthe, Laurie; Julcour-Lebigue, Carine
2015-07-01
This work aims at investigating for the first time the key sonication (US) parameters: power density (DUS), intensity (IUS), and frequency (FS) - down to audible range, under varied hydrostatic pressure (Ph) and low temperature isothermal conditions (to avoid any thermal effect). The selected application was activated sludge disintegration, a major industrial US process. For a rational approach all comparisons were made at same specific energy input (ES, US energy per solid weight) which is also the relevant economic criterion. The decoupling of power density and intensity was obtained by either changing the sludge volume or most often by changing probe diameter, all other characteristics being unchanged. Comprehensive results were obtained by varying the hydrostatic pressure at given power density and intensity. In all cases marked maxima of sludge disintegration appeared at optimum pressures, which values increased at increasing power intensity and density. Such optimum was expected due to opposite effects of increasing hydrostatic pressure: higher cavitation threshold then smaller and fewer bubbles, but higher temperature and pressure at the end of collapse. In addition the first attempt to lower US frequency down to audible range was very successful: at any operation condition (DUS, IUS, Ph, sludge concentration and type) higher sludge disintegration was obtained at 12 kHz than at 20 kHz. The same values of optimum pressure were observed at 12 and 20 kHz. At same energy consumption the best conditions - obtained at 12 kHz, maximum power density 720 W/L and 3.25 bar - provided about 100% improvement with respect to usual conditions (1 bar, 20 kHz). Important energy savings and equipment size reduction may then be expected. Copyright © 2014 Elsevier B.V. All rights reserved.
High frequency pressure oscillator for microcryocoolers.
Vanapalli, S; ter Brake, H J M; Jansen, H V; Zhao, Y; Holland, H J; Burger, J F; Elwenspoek, M C
2008-04-01
Microminiature pulse tube cryocoolers should operate at a frequency of an order higher than the conventional macro ones because the pulse tube cryocooler operating frequency scales inversely with the square of the pulse tube diameter. In this paper, the design and experiments of a high frequency pressure oscillator is presented with the aim to power a micropulse tube cryocooler operating between 300 and 80 K, delivering a cooling power of 10 mW. Piezoelectric actuators operate efficiently at high frequencies and have high power density making them good candidates as drivers for high frequency pressure oscillator. The pressure oscillator described in this work consists of a membrane driven by a piezoelectric actuator. A pressure ratio of about 1.11 was achieved with a filling pressure of 2.5 MPa and compression volume of about 22.6 mm(3) when operating the actuator with a peak-to-peak sinusoidal voltage of 100 V at a frequency of 1 kHz. The electrical power input was 2.73 W. The high pressure ratio and low electrical input power at high frequencies would herald development of microminiature cryocoolers.
High frequency pressure oscillator for microcryocoolers
NASA Astrophysics Data System (ADS)
Vanapalli, S.; ter Brake, H. J. M.; Jansen, H. V.; Zhao, Y.; Holland, H. J.; Burger, J. F.; Elwenspoek, M. C.
2008-04-01
Microminiature pulse tube cryocoolers should operate at a frequency of an order higher than the conventional macro ones because the pulse tube cryocooler operating frequency scales inversely with the square of the pulse tube diameter. In this paper, the design and experiments of a high frequency pressure oscillator is presented with the aim to power a micropulse tube cryocooler operating between 300 and 80K, delivering a cooling power of 10mW. Piezoelectric actuators operate efficiently at high frequencies and have high power density making them good candidates as drivers for high frequency pressure oscillator. The pressure oscillator described in this work consists of a membrane driven by a piezoelectric actuator. A pressure ratio of about 1.11 was achieved with a filling pressure of 2.5MPa and compression volume of about 22.6mm3 when operating the actuator with a peak-to-peak sinusoidal voltage of 100V at a frequency of 1kHz. The electrical power input was 2.73W. The high pressure ratio and low electrical input power at high frequencies would herald development of microminiature cryocoolers.
47 CFR 97.301 - Authorized frequency bands.
Code of Federal Regulations, 2013 CFR
2013-10-01
...: Wavelength band MF ITU region 1 kHz ITU region 2 kHz ITU region 3 kHz Sharing requirements see § 97.303... Advanced Class: Wavelength band MF ITU region 1 kHz ITU region 2 kHz ITU region 3 kHz Sharing requirements... General Class: Wavelength band MF ITU region 1 kHz ITU region 2 kHz ITU region 3 kHz Sharing requirements...
47 CFR 97.301 - Authorized frequency bands.
Code of Federal Regulations, 2012 CFR
2012-10-01
...: Wavelength band MF ITU region 1 kHz ITU region 2 kHz ITU region 3 kHz Sharing requirements see § 97.303... Advanced Class: Wavelength band MF ITU region 1 kHz ITU region 2 kHz ITU region 3 kHz Sharing requirements... General Class: Wavelength band MF ITU region 1 kHz ITU region 2 kHz ITU region 3 kHz Sharing requirements...
47 CFR 97.301 - Authorized frequency bands.
Code of Federal Regulations, 2011 CFR
2011-10-01
...: Wavelength band MF ITU region 1 kHz ITU region 2 kHz ITU region 3 kHz Sharing requirements see § 97.303... Advanced Class: Wavelength band MF ITU region 1 kHz ITU region 2 kHz ITU region 3 kHz Sharing requirements... General Class: Wavelength band MF ITU region 1 kHz ITU region 2 kHz ITU region 3 kHz Sharing requirements...
47 CFR 97.301 - Authorized frequency bands.
Code of Federal Regulations, 2014 CFR
2014-10-01
...: Wavelength band MF ITU region 1 kHz ITU region 2 kHz ITU region 3 kHz Sharing requirements see § 97.303... Advanced Class: Wavelength band MF ITU region 1 kHz ITU region 2 kHz ITU region 3 kHz Sharing requirements... General Class: Wavelength band MF ITU region 1 kHz ITU region 2 kHz ITU region 3 kHz Sharing requirements...
Code of Federal Regulations, 2013 CFR
2013-10-01
... Aircraft Stations § 87.187 Frequencies. (a) Frequencies used for air-ground Communications are listed in... over the high seas. (d) 500 kHz an international calling and distress frequency for aircraft on flights... air-ground communications. (g) The frequency 4125 kHz may be used for distress and safety...
Code of Federal Regulations, 2011 CFR
2011-10-01
... Aircraft Stations § 87.187 Frequencies. (a) Frequencies used for air-ground Communications are listed in... over the high seas. (d) 500 kHz an international calling and distress frequency for aircraft on flights... air-ground communications. (g) The frequency 4125 kHz may be used for distress and safety...
Code of Federal Regulations, 2012 CFR
2012-10-01
... Aircraft Stations § 87.187 Frequencies. (a) Frequencies used for air-ground Communications are listed in... over the high seas. (d) 500 kHz an international calling and distress frequency for aircraft on flights... air-ground communications. (g) The frequency 4125 kHz may be used for distress and safety...
Code of Federal Regulations, 2010 CFR
2010-10-01
... Aircraft Stations § 87.187 Frequencies. (a) Frequencies used for air-ground Communications are listed in... over the high seas. (d) 500 kHz an international calling and distress frequency for aircraft on flights... air-ground communications. (g) The frequency 4125 kHz may be used for distress and safety...
Code of Federal Regulations, 2014 CFR
2014-10-01
... Aircraft Stations § 87.187 Frequencies. (a) Frequencies used for air-ground Communications are listed in... over the high seas. (d) 500 kHz an international calling and distress frequency for aircraft on flights... air-ground communications. (g) The frequency 4125 kHz may be used for distress and safety...
Killer whale (Orcinus orca) hearing: auditory brainstem response and behavioral audiograms.
Szymanski, M D; Bain, D E; Kiehl, K; Pennington, S; Wong, S; Henry, K R
1999-08-01
Killer whale (Orcinus orca) audiograms were measured using behavioral responses and auditory evoked potentials (AEPs) from two trained adult females. The mean auditory brainstem response (ABR) audiogram to tones between 1 and 100 kHz was 12 dB (re 1 mu Pa) less sensitive than behavioral audiograms from the same individuals (+/- 8 dB). The ABR and behavioral audiogram curves had shapes that were generally consistent and had the best threshold agreement (5 dB) in the most sensitive range 18-42 kHz, and the least (22 dB) at higher frequencies 60-100 kHz. The most sensitive frequency in the mean Orcinus audiogram was 20 kHz (36 dB), a frequency lower than many other odontocetes, but one that matches peak spectral energy reported for wild killer whale echolocation clicks. A previously reported audiogram of a male Orcinus had greatest sensitivity in this range (15 kHz, approximately 35 dB). Both whales reliably responded to 100-kHz tones (95 dB), and one whale to a 120-kHz tone, a variation from an earlier reported high-frequency limit of 32 kHz for a male Orcinus. Despite smaller amplitude ABRs than smaller delphinids, the results demonstrated that ABR audiometry can provide a useful suprathreshold estimate of hearing range in toothed whales.
A compact and continuously driven supersonic plasma and neutral source.
Asai, T; Itagaki, H; Numasawa, H; Terashima, Y; Hirano, Y; Hirose, A
2010-10-01
A compact and repetitively driven plasma source has been developed by utilizing a magnetized coaxial plasma gun (MCPG) for diagnostics requiring deep penetration of a large amount of neutral flux. The system consists of a MCPG 95mm in length with a DN16 ConFlat connection port and an insulated gate bipolar transistor (IGBT) inverter power unit. The power supply consists of an array of eight IGBT units and is able to switch the discharge on and off at up to 10 kV and 600 A with a maximum repetitive frequency of 10 kHz. Multiple short duration discharge pulses maximize acceleration efficiency of the plasmoid. In the case of a 10 kHz operating frequency, helium-plasmoids in the velocity range of 20 km/s can be achieved.
NASA Astrophysics Data System (ADS)
Bale, S. D.; Kellogg, P. J.; Erickson, K. N.; Monson, S. J.; Arnoldy, R. L.
During electron beam injection, the Echo 7 rocket experiment observed large bursts of transversely accelerated ions. These ions seem to have been energized in the region of the beam or the payload return current. Electric field waveforms (<= 30 kHz) during gun operation show both low frequency fluctuations and broad band power. An analysis of the waveforms shows nonlinear mode coupling between waves near the ion cyclotron frequency and waves above the lower hybrid frequency.
Characteristics of magnetospheric radio noise spectra
NASA Technical Reports Server (NTRS)
Herman, J. R.
1976-01-01
Magnetospheric radio noise spectra (30 kHz to 10 MHz) taken by IMP-6 and RAE-2 exhibit time-varying characteristics which are related to spacecraft position and magnetospheric processes. In the mid-frequency range (100-1,000 kHz) intense noise peaks rise by a factor of 100 or more above background; 80% of the peak frequencies are within the band 125 kHz to 600 kHz, and the peak occurs most often (18% of the time) at 280 kHz. This intense mid-frequency noise has been detected at radial distances from 1.3 Re to 60 Re on all sides of the Earth during magnetically quiet as well as disturbed periods. Maximum occurrence of the mid-frequency noise is in the evening to midnight hours where splash-type energetic particle precipitation takes place. ""Magnetospheric lightning'' can be invoked to explain the spectral shape of the observed spectra.
Monolithic all-fiber repetition-rate tunable gain-switched single-frequency Yb-doped fiber laser.
Hou, Yubin; Zhang, Qian; Qi, Shuxian; Feng, Xian; Wang, Pu
2016-12-12
We report a monolithic gain-switched single-frequency Yb-doped fiber laser with widely tunable repetition rate. The single-frequency laser operation is realized by using an Yb-doped distributed Bragg reflection (DBR) fiber cavity, which is pumped by a commercial-available laser diode (LD) at 974 nm. The LD is electronically modulated by the driving current and the diode output contains both continuous wave (CW) and pulsed components. The CW component is set just below the threshold of the single-frequency fiber laser for reducing the requirement of the pump pulse energy. Above the threshold, the gain-switched oscillation is trigged by the pulsed component of the diode. Single-frequency pulsed laser output is achieved at 1.063 μm with a pulse duration of ~150 ns and a linewidth of 14 MHz. The repetition rate of the laser output can be tuned between 10 kHz and 400 kHz by tuning the electronic trigger signal. This kind of lasers shows potential for the applications in the area of coherent LIDAR etc.
NASA Astrophysics Data System (ADS)
Kitauchi, H.; Nozaki, K.; Ito, H.; Tsuchiya, S.; Imamura, K.; Nagatsuma, T.
2013-12-01
We first obtained a strong evidence of reception of the low frequency (LF) radio waves, 40 kHz and 60 kHz, of the call sign JJY by use of a newly developed, highly sensitive receiving system on board the Japanese Antarctic research icebreaker Shirase offshore East Ongul Island, East Antarctica--about 14,000 km away from those transmitting stations in Japan. The measured data sets of the electric field intensity and phase of those signals are to be analysed to examine and/or improve numerical prediction methods of field strength for long-distance propagation of LF radio waves, contributing to the Recommendation 'Prediction of field strength at frequencies below about 150 kHz' made by International Telecommunication Union Radiocommunication Sector (ITU-R). The call sign JJY of standard frequency and time signals (SFTS) of LF 40 kHz and 60 kHz are emitted from the transmitting stations, respectively, Ohtakadoya-yama 37° 22‧ 21″ N, 140° 50‧ 56″ E in Fukushima Prefecture (eastern Japan) and Hagane-yama 33° 27‧ 56″ N, 130° 10‧ 32″ E in Saga/Fukuoka Prefecture (western Japan) by NICT. Those are widely used for calibrating frequency standard oscillators and radio-controlled clocks in Japan. Since low signal attenuation in LF radio band allows long distance communication, kilometre waves have been utilized for operations such as SFTS and military communications around the world. Therefore, there is a need to give guidance to engineers for the planning of radio services in LF band so as to avoid interference. ITU-R recommends the guidance 'Prediction of field strength at frequencies below about 150 kHz', in which a numerical prediction method is proposed to compute the electric field intensity, up to 16,000 km of long-distance propagation, away from the transmitting station. Since reliable data sets are limited for the long-distance propagation, in this study we tried to measure the field strength and phase of the LF SFTS JJY of 40 kHz and 60 kHz over 14,000 km away from those transmitting stations for further examination of the numerical prediction method. As part of the Japanese Antarctic Research Expedition (JARE), NICT conducts ionospheric observation during the round trip between Tokyo, Japan and Syowa Station, the Japanese Antarctic base, at 69° 00‧ S, 39° 35‧ E on East Ongul Island, Lutzow-Holm Bay, East Antarctica. In this research we make measurements of the electric field intensity and phase of those signals, continuously along both the ways between Tokyo and Syowa Station, by a newly developed, highly sensitive receiving system installed on board the Japanese Antarctic research icebreaker Shirase. During the 53rd JARE from November 2011 to April 2012, we conducted the measurements to obtain a strong evidence of reception of the LF SFTS JJY of 40 kHz and 60 kHz offshore East Ongul Island, East Antarctica--about 14,000 km away from those transmitting stations in Japan. We applied phase tracking technique to identify the reception of those signals, for the field strengths of the JJY radio waves are so weak in Lutzow-Holm Bay that it is difficult to distinguish between the signals and noises. The measured data sets are to be analysed for further examination and/or improvement of the numerical prediction method of field strength for long-distance propagation of LF radio waves.
Signal and Noise in FET-Nanopore Devices.
Parkin, William M; Drndić, Marija
2018-02-23
The combination of a nanopore with a local field-effect transistor (FET-nanopore), like a nanoribbon, nanotube, or nanowire, in order to sense single molecules translocating through the pore is promising for DNA sequencing at megahertz bandwidths. Previously, it was experimentally determined that the detection mechanism was due to local potential fluctuations that arise when an analyte enters a nanopore and constricts ion flow through it, rather than the theoretically proposed mechanism of direct charge coupling between the DNA and nanowire. However, there has been little discussion on the experimentally observed detection mechanism and its relation to the operation of real devices. We model the intrinsic signal and noise in such an FET-nanopore device and compare the results to the ionic current signal. The physical dimensions of DNA molecules limit the change in gate voltage on the FET to below 40 mV. We discuss the low-frequency flicker noise (<10 kHz), medium-frequency thermal noise (<100 kHz), and high-frequency capacitive noise (>100 kHz) in FET-nanopore devices. At bandwidths dominated by thermal noise, the signal-to-noise ratio in FET-nanopore devices is lower than in the ionic current signal. At high frequencies, where noise due to parasitic capacitances in the amplifier and chip is the dominant source of noise in ionic current measurements, high-transconductance FET-nanopore devices can outperform ionic current measurements.
47 CFR 87.149 - Special requirements for automatic link establishment (ALE).
Code of Federal Regulations, 2011 CFR
2011-10-01
... exceed 100 W ERP; (b) Transmissions must sweep linearly in frequency at a rate of at least 60 kHz per... frequencies and frequency bands must not exceed 10 µW peak ERP: (1) Protected frequencies (kHz) 2091.0 4188.0...
NASA Technical Reports Server (NTRS)
Konoplev, Oleg A.; Chiragh, Furqan L.; Vasilyev, Aleksey A.; Edwards, Ryan; Stephen, Mark A.; Troupaki, Elisavet; Yu, Anthony W.; Krainak, Michael A.; Sawruk, Nick; Hovis, Floyd;
2016-01-01
We present the results of three year life-aging of a specially designed prototype flight source laser operating at 1064 nm, 10 kHz, 1ns, 15W average power and external frequency doubler. The Fibertek-designed, slightly pressurized air, enclosed-container source laser operated at 1064 nm in active Q-switching mode. The external frequency doubler was set in a clean room at a normal air pressure. The goal of the experiment was to measure degradation modes at 1064 and 532 nm discreetly. The external frequency doubler consisted of a Lithium triborate, LiB3O5, crystal operated at non-critical phase-matching. Due to 1064 nm diagnostic needs, the amount of fundamental frequency power available for doubling was 13.7W. The power generated at 532 nm was between 8.5W and 10W, depending on the level of stress and degradation. The life-aging consisted of double stress-step operation for doubler crystal, at 0.35 J/cm2 for almost 1 year, corresponding to normal conditions, and then at 0.93 J/cm2 for the rest of the experiment, corresponding to accelerated testing. We observed no degradation at the first step and linear degradation at the second step. The linear degradation at the second stress-step was related to doubler crystal output surface changes and linked to laser-assisted contamination. We discuss degradation model and estimate the expected lifetime for the flight laser at 532 nm. This work was done within the laser testing for NASA's Ice, Cloud, and land Elevation Satellite-2 (ICESat-2) LIDAR at Goddard Space Flight Center in Greenbelt, MD with the goal of 1 trillion shots lifetime.
NASA Technical Reports Server (NTRS)
Konoplev, Oleg A.; Chiragh, Furqan L.; Vasilyev, Aleksey A.; Edwards, Ryan; Stephen, Mark A.; Troupaki, Elisavet; Yu, Anthony W.; Krainak, Michael A.; Sawruk, Nick; Hovis, Floyd;
2016-01-01
We present the results of three year life-aging of a specially designed prototype flight source laser operating at 1064 nm, 10 kHz, 1ns, 15W average power and external frequency doubler. The Fibertek-designed, slightly pressurized air, enclosed-container source laser operated at 1064 nm in active Q-switching mode. The external frequency doubler was set in a clean room at a normal air pressure. The goal of the experiment was to measure degradation modes at 1064 and 532 nm discreetly. The external frequency doubler consisted of a Lithium triborate, LiB3O5, crystal operated at non-critical phase-matching. Due to 1064 nm diagnostic needs, the amount of fundamental frequency power available for doubling was 13.7W. The power generated at 532 nm was between 8.5W and 10W, depending on the level of stress and degradation. The life-aging consisted of double stress-step operation for doubler crystal, at 0.35 Jcm2 for almost 1 year, corresponding to normal conditions, and then at 0.93 Jcm2 for the rest of the experiment, corresponding to accelerated testing. We observed no degradation at the first step and linear degradation at the second step. The linear degradation at the second stress-step was related to doubler crystal output surface changes and linked to laser-assisted contamination. We discuss degradation model and estimate the expected lifetime for the flight laser at 532 nm. This work was done within the laser testing for NASAs Ice, Cloud, and land Elevation Satellite-2 (ICESat-2) LIDAR at Goddard Space Flight Center in Greenbelt, MD with the goal of 1 trillion shots lifetime.
Effects of Sound Frequency on Audiovisual Integration: An Event-Related Potential Study.
Yang, Weiping; Yang, Jingjing; Gao, Yulin; Tang, Xiaoyu; Ren, Yanna; Takahashi, Satoshi; Wu, Jinglong
2015-01-01
A combination of signals across modalities can facilitate sensory perception. The audiovisual facilitative effect strongly depends on the features of the stimulus. Here, we investigated how sound frequency, which is one of basic features of an auditory signal, modulates audiovisual integration. In this study, the task of the participant was to respond to a visual target stimulus by pressing a key while ignoring auditory stimuli, comprising of tones of different frequencies (0.5, 1, 2.5 and 5 kHz). A significant facilitation of reaction times was obtained following audiovisual stimulation, irrespective of whether the task-irrelevant sounds were low or high frequency. Using event-related potential (ERP), audiovisual integration was found over the occipital area for 0.5 kHz auditory stimuli from 190-210 ms, for 1 kHz stimuli from 170-200 ms, for 2.5 kHz stimuli from 140-200 ms, 5 kHz stimuli from 100-200 ms. These findings suggest that a higher frequency sound signal paired with visual stimuli might be early processed or integrated despite the auditory stimuli being task-irrelevant information. Furthermore, audiovisual integration in late latency (300-340 ms) ERPs with fronto-central topography was found for auditory stimuli of lower frequencies (0.5, 1 and 2.5 kHz). Our results confirmed that audiovisual integration is affected by the frequency of an auditory stimulus. Taken together, the neurophysiological results provide unique insight into how the brain processes a multisensory visual signal and auditory stimuli of different frequencies.
Distributed measurement of acoustic vibration location with frequency multiplexed phase-OTDR
NASA Astrophysics Data System (ADS)
Iida, Daisuke; Toge, Kunihiro; Manabe, Tetsuya
2017-07-01
All-fiber distributed vibration sensing is attracting attention in relation to structural health monitoring because it is cost effective, offers high coverage of the monitored area and can detect various structural problems. And in particular the demand for high-speed vibration sensing operating at more than 10 kHz has increased because high frequency vibration indicates high energy and severe trouble in the monitored object. Optical fiber vibration sensing with phase-sensitive optical time domain reflectometry (phase-OTDR) has long been studied because it can be used for distributed vibration sensing in optical fiber. However, pulse reflectometry such as OTDR cannot measure high-frequency vibration whose cycle is shorter than the repetition time of the OTDR. That is, the maximum detectable frequency depends on fiber length. In this paper, we describe a vibration sensing technique with frequency-multiplexed OTDR that can detect the entire distribution of a high-frequency vibration thus allowing us to locate a high-speed vibration point. We can measure the position, frequency and dynamic change of a high-frequency vibration whose cycle is shorter than the repetition time. Both frequency and position are visualized simultaneously for a 5-km fiber with an 80-kHz frequency response and a 20-m spatial resolution.
NASA Technical Reports Server (NTRS)
Heppner, J. P.; Liebrecht, M. C.; Maynard, N. C.; Pfaff, R. F.
1993-01-01
The high-latitude spatial distributions of average signal intensities in 12 frequency channels between 4 Hz and 512 kHz as measured by the ac electric field spectrometers on the DE-2 spacecraft are analyzed for 18 mo of measurements. In MLT-INL (magnetic local time-invariant latitude) there are three distinct distributions that can be identified with 4-512 Hz signals from spatial irregularities and Alfven waves, 256-Hz to 4.1-kHz signals from ELF hiss, and 4.1-64 kHz signals from VLF auroral hiss, respectively. Overlap between ELF hiss and spatial irregularity signals occurs in the 256-512 Hz band. VLF hiss signals extend downward in frequency into the 1.0-4.1 kHz band and upward into the frequency range 128-512 kHz. The distinctly different spatial distribution patterns for the three bands, 4-256 Hz, 512-1204 Hz, and 4.1-64 kHz, indicate a lack of any causal relationships between VLF hiss, ELF hiss, and lower-frequency signals from spatial irregularities and Alfven waves.
47 CFR 101.107 - Frequency tolerance.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., this tolerance will govern the marketing of LTTS equipment and the issuance of all such authorizations... stations providing MVDDS. 5 For private operational fixed point-to-point microwave systems, with a channel... address remote stations with channels greater than 12.5 KHz bandwidth, ±0.0005%. 6 For stations authorized...
NASA Technical Reports Server (NTRS)
Mclyman, C. W.
1983-01-01
Compact dc/dc inverter uses single integrated-circuit package containing six inverter gates that generate and amplify 100-kHz square-wave switching signal. Square-wave switching inverts 10-volt local power to isolated voltage at another desired level. Relatively high operating frequency reduces size of filter capacitors required, resulting in small package unit.
14 CFR Appendix E to Part 29 - HIRF Environments and Equipment HIRF Test Levels
Code of Federal Regulations, 2010 CFR
2010-01-01
... following table: Table I.—HIRF Environment I Frequency Field strength(volts/meter) Peak Average 10 kHz-2 MHz 50 50 2 MHz-30 MHz 100 100 30 MHz-100 MHz 50 50 100 MHz-400 MHz 100 100 400 MHz-700 MHz 700 50 700... Environment II Frequency Field strength(volts/meter) Peak Average 10 kHz-500 kHz 20 20 500 kHz-2 MHz 30 30 2...
14 CFR Appendix D to Part 27 - HIRF Environments and Equipment HIRF Test Levels
Code of Federal Regulations, 2010 CFR
2010-01-01
... following table: Table I.—HIRF Environment I Frequency Field strength(volts/meter) Peak Average 10 kHz-2 MHz 50 50 2 MHz-30 MHz 100 100 30 MHz-100 MHz 50 50 100 MHz-400 MHz 100 100 400 MHz-700 MHz 700 50 700... Environment II Frequency Field strength(volts/meter) Peak Average 10 kHz-500 kHz 20 20 500 kHz-2 MHz 30 30 2...
Mora, E C; Macías, S; Vater, M; Coro, F; Kössl, M
2004-07-01
While searching for prey, Molossus molossus broadcasts narrow-band calls of 11.42 ms organized in pairs of pulses that alternate in frequency. The first signal of the pair is at 34.5 kHz, the second at 39.6 kHz. Pairs of calls with changing frequencies were only emitted when the interpulse intervals were below 200 ms. Maximum duty cycles during search phase are close to 20%. Frequency alternation of search calls is interpreted as a mechanism for increasing duty cycle and thus the temporal continuity of scanning, as well as increasing the detection range. A neurophysiological correlate for the processing of search calls was found in the inferior colliculus. 64% of neurons respond to frequencies in the 30- to 40-kHz range and only in this frequency range were closed tuning curves found for levels below 40 dB SPL. In addition, 15% of the neurons have double-tuned frequency-threshold curves with best thresholds at 34 and 39 kHz. Differing from observations in other bats, approach calls of M. molossus are longer and of higher frequencies than search calls. Close to the roost, the call frequency is increased to 45.0-49.8 kHz and, in addition, extremely broadband signals are emitted. This demonstrates high plasticity of call design.
A fully integrated neural recording amplifier with DC input stabilization.
Mohseni, Pedram; Najafi, Khalil
2004-05-01
This paper presents a low-power low-noise fully integrated bandpass operational amplifier for a variety of biomedical neural recording applications. A standard two-stage CMOS amplifier in a closed-loop resistive feedback configuration provides a stable ac gain of 39.3 dB at 1 kHz. A subthreshold PMOS input transistor is utilized to clamp the large and random dc open circuit potentials that normally exist at the electrode-electrolyte interface. The low cutoff frequency of the amplifier is programmable up to 50 Hz, while its high cutoff frequency is measured to be 9.1 kHz. The tolerable dc input range is measured to be at least +/- 0.25 V with a dc rejection factor of at least 29 dB. The amplifier occupies 0.107 mm2 in die area, and dissipates 115 microW from a 3 V power supply. The total measured input-referred noise voltage in the frequency range of 0.1-10 kHz is 7.8 microVrms. It is fabricated using AMI 1.5 microm double-poly double-metal n-well CMOS process. This paper presents full characterization of the dc, ac, and noise performance of this amplifier through in vitro measurements in saline using two different neural recording electrodes.
Wang, Zhi-Bin; Zhang, Rui; Wang, Yao-Li; Huang, Yan-Fei; Chen, You-Hua; Wang, Li-Fu; Yang, Qiang
2014-02-01
As the existing photoelastic-modulator(PEM) modulating frequency in the tens of kHz to hundreds of kHz between, leading to frequency of modulated interference signal is higher, so ordinary array detector cannot effectively caprure interference signal..A new beat frequency modulation method based on dual-photoelastic-modulator (Dual-PEM) and Fourier-Bessel transform is proposed as an key component of dual-photoelastic-modulator-based imaging spectrometer (Dual-PEM-IS) combined with charge coupled device (CCD). The dual-PEM are operated as an electro-optic circular retardance modulator, Operating the PEMs at slightly different resonant frequencies w1 and w2 respectively, generates a differential signal at a much lower heterodyne frequency that modulates the incident light. This method not only retains the advantages of the existing PEM, but also the frequency of modulated photocurrent decreased by 2-3 orders of magnitude (10-500 Hz) and can be detected by common array detector, and the incident light spectra can be obtained by Fourier-Bessel transform of low frequency component in the modulated signal. The method makes the PEM has the dual capability of imaging and spectral measurement. The basic principle is introduced, the basic equations is derived, and the feasibility is verified through the corresponding numerical simulation and experiment. This method has' potential applications in imaging spectrometer technology, and analysis of the effect of deviation of the optical path difference. This work provides the necessary theoretical basis for remote sensing of new Dual-PEM-IS and for engineering implementation of spectra inversion.
Advanced electrical power, distribution and control for the Space Transportation System
NASA Astrophysics Data System (ADS)
Hansen, Irving G.; Brandhorst, Henry W., Jr.
1990-08-01
High frequency power distribution and management is a technology ready state of development. As such, a system employs the fewest power conversion steps, and employs zero current switching for those steps. It results in the most efficiency, and lowest total parts system count when equivalent systems are compared. The operating voltage and frequency are application specific trade off parameters. However, a 20 kHz Hertz system is suitable for wide range systems.
Advanced electrical power, distribution and control for the Space Transportation System
NASA Technical Reports Server (NTRS)
Hansen, Irving G.; Brandhorst, Henry W., Jr.
1990-01-01
High frequency power distribution and management is a technology ready state of development. As such, a system employs the fewest power conversion steps, and employs zero current switching for those steps. It results in the most efficiency, and lowest total parts system count when equivalent systems are compared. The operating voltage and frequency are application specific trade off parameters. However, a 20 kHz Hertz system is suitable for wide range systems.
Lightweight multiple output converter development
NASA Technical Reports Server (NTRS)
Kisch, J. J.; Martinelli, R. M.
1978-01-01
A high frequency, multiple output power conditioner was developed and breadboarded using an eight-stage capacitor diode voltage multiplier to provide +1200 Vdc, and a three-stage for -350 Vdc. In addition, two rectifier bridges were capacitively coupled to the eight-stage multiplier to obtain 0.5 and 0.65 a dc constant current outputs referenced to +1200 Vdc. Total power was 120 watts, with an overall efficiency of 85 percent at the 80 kHz operating frequency. All outputs were regulated to three percent or better, with complete short circuit protection. The power conditioner component weight and efficiency were compared to the equivalent four outputs of the 10 kHz conditioner for the 8 cm ion engine. Weight reduction for the four outputs was 557 grams; extrapolated in the same ratio to all nine outputs, it would be 1100 to 1400 grams.
Effect of Electrical Current Stimulation on Pseudomonas Aeruginosa Growth
NASA Astrophysics Data System (ADS)
Alneami, Auns Q.; Khalil, Eman G.; Mohsien, Rana A.; Albeldawi, Ali F.
2018-05-01
The present study evaluates the effect of electrical current with different frequencies stimulation to kill pathogenic Pseudomonas aeruginosa (PA) bacteria in vitro using human safe level of electricity controlled by function generator. A wide range of frequencies has been used from 0.5 Hz-1.2 MHz to stimulate the bacteria at a voltage of 20 p-p volt for different periods of time (5 to 30) minutes. The culture of bacteria used Nickel, Nichrome, or Titanium electrode using agarose in phosphate buffer saline (PBS) and mixed with bacterial stock activated by trypticase soy broth (TSB). The results of frequencies between 0.5-1 KHz show the inhibition zone diameter of 20 mm in average at 30 minutes of stimulation. At frequencies between 3-60 KHz the inhibition zone diameter was only 10mm for 30 minutes of stimulation. While the average of inhibition zone diameter increased to more than 30mm for 30 minutes of stimulation at frequencies between 80-120 KHz. From this study we conclude that at specific frequency (resonance frequency) (frequencies between 0.5-1 KHz) there was relatively large inhibition zone because the inductive reactance effect is equal to the value of capacitive reactance effect (XC = XL). At frequencies over than 60 KHz, maximum inhibition zone noticed because the capacitance impedance becomes negligible (only the small resistivity of the bacterial internal organs).
Fukushima, Ariko; Yagi, Reiko; Kawai, Norie; Honda, Manabu; Nishina, Emi; Oohashi, Tsutomu
2014-01-01
The hypersonic effect is a phenomenon in which sounds containing significant quantities of non-stationary high-frequency components (HFCs) above the human audible range (max. 20 kHz) activate the midbrain and diencephalon and evoke various physiological, psychological and behavioral responses. Yet important issues remain unverified, especially the relationship existing between the frequency of HFCs and the emergence of the hypersonic effect. In this study, to investigate the relationship between the hypersonic effect and HFC frequencies, we divided an HFC (above 16 kHz) of recorded gamelan music into 12 band components and applied them to subjects along with an audible component (below 16 kHz) to observe changes in the alpha2 frequency component (10-13 Hz) of spontaneous EEGs measured from centro-parieto-occipital regions (Alpha-2 EEG), which we previously reported as an index of the hypersonic effect. Our results showed reciprocal directional changes in Alpha-2 EEGs depending on the frequency of the HFCs presented with audible low-frequency component (LFC). When an HFC above approximately 32 kHz was applied, Alpha-2 EEG increased significantly compared to when only audible sound was applied (positive hypersonic effect), while, when an HFC below approximately 32 kHz was applied, the Alpha-2 EEG decreased (negative hypersonic effect). These findings suggest that the emergence of the hypersonic effect depends on the frequencies of inaudible HFC.
The effect of recording and analysis bandwidth on acoustic identification of delphinid species.
Oswald, Julie N; Rankin, Shannon; Barlow, Jay
2004-11-01
Because many cetacean species produce characteristic calls that propagate well under water, acoustic techniques can be used to detect and identify them. The ability to identify cetaceans to species using acoustic methods varies and may be affected by recording and analysis bandwidth. To examine the effect of bandwidth on species identification, whistles were recorded from four delphinid species (Delphinus delphis, Stenella attenuata, S. coeruleoalba, and S. longirostris) in the eastern tropical Pacific ocean. Four spectrograms, each with a different upper frequency limit (20, 24, 30, and 40 kHz), were created for each whistle (n = 484). Eight variables (beginning, ending, minimum, and maximum frequency; duration; number of inflection points; number of steps; and presence/absence of harmonics) were measured from the fundamental frequency of each whistle. The whistle repertoires of all four species contained fundamental frequencies extending above 20 kHz. Overall correct classification using discriminant function analysis ranged from 30% for the 20-kHz upper frequency limit data to 37% for the 40-kHz upper frequency limit data. For the four species included in this study, an upper bandwidth limit of at least 24 kHz is required for an accurate representation of fundamental whistle contours.
Detection of NMR signals with a radio-frequency atomic magnetometer.
Savukov, I M; Seltzer, S J; Romalis, M V
2007-04-01
We demonstrate detection of proton NMR signals with a radio-frequency (rf) atomic magnetometer tuned to the NMR frequency of 62 kHz. High-frequency operation of the atomic magnetometer makes it relatively insensitive to ambient magnetic field noise. We obtain magnetic field sensitivity of 7 fT/Hz1/2 using only a thin aluminum shield. We also derive an expression for the fundamental sensitivity limit of a surface inductive pick-up coil as a function of frequency and find that an atomic rf magnetometer is intrinsically more sensitive than a coil of comparable size for frequencies below about 50 MHz.
Effects of Sound Frequency on Audiovisual Integration: An Event-Related Potential Study
Yang, Weiping; Yang, Jingjing; Gao, Yulin; Tang, Xiaoyu; Ren, Yanna; Takahashi, Satoshi; Wu, Jinglong
2015-01-01
A combination of signals across modalities can facilitate sensory perception. The audiovisual facilitative effect strongly depends on the features of the stimulus. Here, we investigated how sound frequency, which is one of basic features of an auditory signal, modulates audiovisual integration. In this study, the task of the participant was to respond to a visual target stimulus by pressing a key while ignoring auditory stimuli, comprising of tones of different frequencies (0.5, 1, 2.5 and 5 kHz). A significant facilitation of reaction times was obtained following audiovisual stimulation, irrespective of whether the task-irrelevant sounds were low or high frequency. Using event-related potential (ERP), audiovisual integration was found over the occipital area for 0.5 kHz auditory stimuli from 190–210 ms, for 1 kHz stimuli from 170–200 ms, for 2.5 kHz stimuli from 140–200 ms, 5 kHz stimuli from 100–200 ms. These findings suggest that a higher frequency sound signal paired with visual stimuli might be early processed or integrated despite the auditory stimuli being task-irrelevant information. Furthermore, audiovisual integration in late latency (300–340 ms) ERPs with fronto-central topography was found for auditory stimuli of lower frequencies (0.5, 1 and 2.5 kHz). Our results confirmed that audiovisual integration is affected by the frequency of an auditory stimulus. Taken together, the neurophysiological results provide unique insight into how the brain processes a multisensory visual signal and auditory stimuli of different frequencies. PMID:26384256
Noise and frequency response of silicon photodiode operational amplifier combination.
Hamstra, R H; Wendland, P
1972-07-01
The noise in dark and illuminated Schottky barrier and diffused PIN non-guard-ring photodiodes has been measured between 0.1 Hz and 10 kHz and compared to theory with an excellent fit. It is shown that diodes used photovoltaically are free of 1/f noise in the dark. It is also demonstrated that there is an optimum bias (ca. 100 mV) for minimum noise equivalent power. When only a resistive load is used with a detector, it often determines the frequency response and noise of the detector circuit. We develop and demonstrate equations for the major improvements in both noise and frequency response that can be obtained using a current mode (inverting) operational amplifier.
Variable speed induction motor operation from a 20-kHz power bus
NASA Technical Reports Server (NTRS)
Hansen, Irving G.
1989-01-01
Induction motors are recognized for their simple rugged construction. To date, however, their application to variable speed or servo drives was hampered by limitations on their control. Induction motor drives tend to be complex and to display troublesome low speed characteristics due in part to nonsinusoidal driving voltages. A technique was developed which involves direct synthesis of sinusoidal driving voltages from a high frequency power bus and independent control of frequency and voltages. Separation of frequency and voltage allows independent control of rotor and stator flux, full four quadrant operation, and instantaneous torque control. Recent test results, current status of the technology, and proposed aerospace applications will be discussed.
High Frequency Analyzer (HFA) of Plasma Wave Experiment (PWE) onboard the Arase spacecraft
NASA Astrophysics Data System (ADS)
Kumamoto, Atsushi; Tsuchiya, Fuminori; Kasahara, Yoshiya; Kasaba, Yasumasa; Kojima, Hirotsugu; Yagitani, Satoshi; Ishisaka, Keigo; Imachi, Tomohiko; Ozaki, Mitsunori; Matsuda, Shoya; Shoji, Masafumi; Matsuoka, Aayako; Katoh, Yuto; Miyoshi, Yoshizumi; Obara, Takahiro
2018-05-01
The High Frequency Analyzer (HFA) is a subsystem of the Plasma Wave Experiment onboard the Arase (ERG) spacecraft. The main purposes of the HFA include (1) determining the electron number density around the spacecraft from observations of upper hybrid resonance (UHR) waves, (2) measuring the electromagnetic field component of whistler-mode chorus in a frequency range above 20 kHz, and (3) observing radio and plasma waves excited in the storm-time magnetosphere. Two components of AC electric fields detected by Wire Probe Antenna and one component of AC magnetic fields detected by Magnetic Search Coils are fed to the HFA. By applying analog and digital signal processing in the HFA, the spectrograms of two electric fields (EE mode) or one electric field and one magnetic field (EB mode) in a frequency range from 10 kHz to 10 MHz are obtained at an interval of 8 s. For the observation of plasmapause, the HFA can also be operated in PP (plasmapause) mode, in which spectrograms of one electric field component below 1 MHz are obtained at an interval of 1 s. In the initial HFA operations from January to July, 2017, the following results are obtained: (1) UHR waves, auroral kilometric radiation (AKR), whistler-mode chorus, electrostatic electron cyclotron harmonic waves, and nonthermal terrestrial continuum radiation were observed by the HFA in geomagnetically quiet and disturbed conditions. (2) In the test operations of the polarization observations on June 10, 2017, the fundamental R-X and L-O mode AKR and the second-harmonic R-X mode AKR from different sources in the northern polar region were observed. (3) The semiautomatic UHR frequency identification by the computer and a human operator was applied to the HFA spectrograms. In the identification by the computer, we used an algorithm for narrowing down the candidates of UHR frequency by checking intensity and bandwidth. Then, the identified UHR frequency by the computer was checked and corrected if needed by the human operator. Electron number density derived from the determined UHR frequency will be useful for the investigation of the storm-time evolution of the plasmasphere and topside ionosphere.[Figure not available: see fulltext.
Ultrasonic pilot-scale reactor for enzymatic bleaching of cotton fabrics.
Gonçalves, Idalina; Herrero-Yniesta, Victor; Perales Arce, Iratxe; Escrigas Castañeda, Monica; Cavaco-Paulo, Artur; Silva, Carla
2014-07-01
The potential of ultrasound-assisted technology has been demonstrated by several laboratory scale studies. However, their successful industrial scaling-up is still a challenge due to the limited pilot and commercial sonochemical reactors. In this work, a pilot reactor for laccase-hydrogen peroxide cotton bleaching assisted by ultrasound was scaled-up. For this purpose, an existing dyeing machine was transformed and adapted by including piezoelectric ultrasonic devices. Laboratory experiments demonstrated that both low frequency, high power (22 kHz, 2100 W) and high frequency, low power ultrasounds (850 kHz, 400 W) were required to achieve satisfactory results. Standard half (4 g/L H2O2 at 90 °C for 60 min) and optical (8 g/L H2O2 at 103 °C for 40 min) cotton bleaching processes were used as references. Two sequential stages were established for cotton bleaching: (1) laccase pretreatment assisted by high frequency ultrasound (850 kHz, 400 W) and (2) bleaching using high power ultrasound (22 kHz, 2100 W). When compared with conventional methods, combined laccase-hydrogen peroxide cotton bleaching with ultrasound energy improved the whitening effectiveness. Subsequently, less energy (temperature) and chemicals (hydrogen peroxide) were needed for cotton bleaching thus resulting in costs reduction. This technology allowed the combination of enzyme and hydrogen peroxide treatment in a continuous process. The developed pilot-scale reactor offers an enhancement of the cotton bleaching process with lower environmental impact as well as a better performance of further finishing operations. Copyright © 2014 Elsevier B.V. All rights reserved.
Giaretta, Ariovaldo Antonio; Vo, Pacific; Herche, Jesse; Tang, Justine Nicole; Gridi-Papp, Marcos
2015-06-13
The advertisement call of Dermatonotus muelleri was originally described by Nelson (1973) in a brief section of a review on the mating calls of the Microhylinae. He used two calls from São Leopoldo, state of Minas Gerais, in Brazil to determine that they have i) dominant frequency between 1.500-2.200 kHz (mean 1.854 + 0.216 kHz), and ii) harmonic intervals between 0.140 and 0.150 kHz (0.146 +/- 0.005 kHz). Nelson (1973) based his description on an audiospectrogram produced with high frequency resolution and did not quantify the pulse structure of the calls. More recently, Giaretta and colleagues (2013) expanded on the original description using a larger set of calls recorded from Gurinhat, state of Minas Gerais, in Brazil. They quantified the temporal structure of the call and confirmed that the dominant frequency is around 1.8 kHz. In addition, they identified a secondary low frequency band at 667 Hz.
Two-tone suppression in the cricket, Eunemobius carolinus (Gryllidae, Nemobiinae)
NASA Astrophysics Data System (ADS)
Farris, Hamilton E.; Hoy, Ronald R.
2002-03-01
Sounds with frequencies >15 kHz elicit an acoustic startle response (ASR) in flying crickets (Eunemobius carolinus). Although frequencies <15 kHz do not elicit the ASR when presented alone, when presented with ultrasound (40 kHz), low-frequency stimuli suppress the ultrasound-induced startle. Thus, using methods similar to those in masking experiments, we used two-tone suppression to assay sensitivity to frequencies in the audio band. Startle suppression was tuned to frequencies near 5 kHz, the frequency range of male calling songs. Similar to equal loudness contours measured in humans, however, equal suppression contours were not parallel, as the equivalent rectangular bandwidth of suppression tuning changed with increases in ultrasound intensity. Temporal integration of suppressor stimuli was measured using nonsimultaneous presentations of 5-ms pulses of 6 and 40 kHz. We found that no suppression occurs when the suppressing tone is >2 ms after and >5 ms before the ultrasound stimulus, suggesting that stimulus overlap is a requirement for suppression. When considered together with our finding that the intensity of low-frequency stimuli required for suppression is greater than that produced by singing males, the overlap requirement suggests that two-tone suppression functions to limit the ASR to sounds containing only ultrasound and not to broadband sounds that span the audio and ultrasound range.
Demodulation RFI statistics for a 3-stage op amp LED circuit
NASA Astrophysics Data System (ADS)
Whalen, James J.
An experiment has been performed to demonstrate the feasibility of combining several methods of electromagnetic-compatibility analysis. The part of the experiment that demonstrates how RF signals cause interference in an audio-frequency (AF) circuit and how the interference can be suppressed is described. The circuit includes three operational amplifiers (op amps) and a light-emitting diode (LED). A 50 percent amplitude-modulated (AM) radio-frequency-interference (RFI) signal is used, varied over the range from 0.1 to 400 MHz. The AM frequency is 1 kHz. The RFI is injected into the inverting input of the first op amp, and the 1-kHz demodulation response of the amplifier is amplified by the second and third op amps and lights the LED to provide a visual display of the existence of RFI. An RFI suppression capacitor was added to reduce the RFI. The demodulation RFI results are presented as scatter plots for 35 741 op amps. Mean values and standard deviations are also shown.
Kumon, R. E.; Gudur, M. S. R.; Zhou, Y.; Deng, C. X.
2012-01-01
Effective real-time monitoring of high-intensity focused ultrasound (HIFU) ablation is important for application of HIFU technology in interventional electrophysiology. This study investigated rapid, high-frequency M-mode ultrasound imaging for monitoring spatiotemporal changes during HIFU application. HIFU (4.33 MHz, 1 kHz PRF, 50% duty cycle, 1 s, 2600 – 6100 W/cm2) was applied to ex-vivo porcine cardiac tissue specimens with a confocally and perpendicularly aligned high-frequency imaging system (Visualsonics Vevo 770, 55 MHz center frequency). Radiofrequency (RF) data from M-mode imaging (1 kHz PRF, 2 s × 7 mm) was acquired before, during, and after HIFU treatment (n = 12). Among several strategies, the temporal maximum integrated backscatter with a threshold of +12 dB change showed the best results for identifying final lesion width (receiver-operating characteristic curve area 0.91 ± 0.04, accuracy 85 ± 8%, as compared to macroscopic images of lesions). A criterion based on a line-to-line decorrelation coefficient is proposed for identification of transient gas bodies. PMID:22341055
NASA Astrophysics Data System (ADS)
Bernstein, Leslie R.; Trahiotis, Constantine
2003-06-01
An acoustic pointing task was used to determine whether interaural temporal disparities (ITDs) conveyed by high-frequency ``transposed'' stimuli would produce larger extents of laterality than ITDs conveyed by bands of high-frequency Gaussian noise. The envelopes of transposed stimuli are designed to provide high-frequency channels with information similar to that conveyed by the waveforms of low-frequency stimuli. Lateralization was measured for low-frequency Gaussian noises, the same noises transposed to 4 kHz, and high-frequency Gaussian bands of noise centered at 4 kHz. Extents of laterality obtained with the transposed stimuli were greater than those obtained with bands of Gaussian noise centered at 4 kHz and, in some cases, were equivalent to those obtained with low-frequency stimuli. In a second experiment, the general effects on lateral position produced by imposed combinations of bandwidth, ITD, and interaural phase disparities (IPDs) on low-frequency stimuli remained when those stimuli were transposed to 4 kHz. Overall, the data were fairly well accounted for by a model that computes the cross-correlation subsequent to known stages of peripheral auditory processing augmented by low-pass filtering of the envelopes within the high-frequency channels of each ear.
2007-09-30
Observing System (NJ SOS), which provides real-time data throughout the Mid-Atlantic Bight (MAB). The surveys will be positioned adaptively using real-time... gastropod were located during a 2-day period. These aggregations were remarkablystrong scatterers at frequencies ranging from 38-200 kHz. Data
Code of Federal Regulations, 2010 CFR
2010-10-01
... available for assignment to serve domestic air routes in the Alaska area: (i) Throughout Alaska: Shared with...) available to enroute stations serving international flight operations on the Major World Air Route Areas...): kHz 2854.0 8861.0 2935.0 11291.0 3452.0 13315.0 5565.0 13357.0 6535.0 17955.0 (9) Southeast Asia...
Long-term measurements of acoustic background noise in very deep sea
NASA Astrophysics Data System (ADS)
Riccobene, G.; NEMO Collaboration
2009-06-01
The NEMO (NEutrino Mediterranean Observatory) Collaboration installed, 25 km E offshore the port of Catania (Sicily) at 2000 m depth, an underwater laboratory to perform long-term tests of prototypes and new technologies for an underwater high energy neutrino km-scale detector in the Mediterranean Sea. In this framework the Collaboration deployed and successfully operated for about two years, starting from January 2005, an experimental apparatus for on-line monitoring of deep-sea noise. The station was equipped with four hydrophones and it is operational in the range 30 Hz-43 kHz. This interval of frequencies matches the range suitable for the proposed acoustic detection technique of high energy neutrinos. Hydrophone signals were digitized underwater at 96 kHz sampling frequency and 24 bits resolution. The stored data library, consisting of more than 2000 h of recordings, is a unique tool to model underwater acoustic noise at large depth, to characterize its variations as a function of environmental parameters, biological sources and human activities (ship traffic, etc.), and to determine the presence of cetaceans in the area.
Ferroresonant Flux-Coupled Battery Charger
NASA Technical Reports Server (NTRS)
Mclyman, C. W.
1986-01-01
Portable battery charger operates at about 20 kHz to take advantage of relatively low weight and low acoustical noise of ferroresonant circuits operating in this frequency range. Charger split into stationary unit connected to powerline and mobile unit connected to battery or other load. Power transferred to mobile unit by magnetic coupling between mating transformer halves. Advantage where sparking at electrical connection might pose explosion hazard or where operator disabled and cannot manipulate plug into wall outlet. Likely applications for charger include wheelchairs and robots.
Heating of the nighttime D region by very low frequency transmitters
NASA Astrophysics Data System (ADS)
Rodriguez, Juan V.; Inan, Umran S.; Bell, Timothy F.
1994-12-01
VLF signals propagating in the Earth-ionosphere waveguide are used to probe the heated nighttime D region over three U.S. Navy very low frequency (VLF,3-30 kHz) transmitters. Ionospheric cooling and heating are observed when a transmitter turns off and on in the course of normal operations. Heating by the 24.0-kHz NAA transmitter in Cutler, Maine, (1000 kW radiated power) was observed by this method in 41 of 52 off/on episodes during December 1992, increasing the amplitude and retarding the phase of the 21.4-kHz NSS probe wave propagating from Annapolis, Maryland, to Gander, Newfoundland, by as much as 0.84 dB and 5.3 deg, respectively. In 6 of these 41 episodes, the amplitude of the 28.5-kHz NAU probe wave propagating from Puerto Rico to Gander was also perturbed by as much as 0.29 dB. The latter observations were unexpected due to the greater than 770 km distance between NAA and the NAU-Gander great circle path. Heating by the NSS (21.4 kHz, 265 kW) and NLK (24.8 kHz, 850 kW) transmitters was observed serendipitously in data from earlier measurements of the amplitudes of VLF signals propagating in the Earth-ionosphere waveguide. A three-dimensional model of wave absorption and electron heating in a magnetized, weakly ionized plasma is used to calculate the extent nad shape of the collision frequency (i.e., electron temperature) enhancement above a VLF transmitter. The enhancements are annular, with a geomagnetic north-south asymmetry and a radius at the outer half-maximum of the collision frequency enhancement of about 150 km. Heating by the NAA transmitter is predicted to increase the nighttime D region electron temperature by as much as a factor of 3. The calculated changes in the D region conductivity are used in a three-dimensional model of propagation in the Earth-ionosphere wavelength to predict the effect of the heated patch on a subionospheric VLF probe wave. The range of predicted scattered field amplitudes is in general consistent with the observed signal perturbations. Discrepanices in the predictions are attributed to lack of knowledge of the D region electron density profile along the probe wave great circle paths.
Heating of the nighttime D region by very low frequency transmitters
NASA Technical Reports Server (NTRS)
Rodriguez, Juan V.; Inan, Umran S.; Bell, Timothy F.
1994-01-01
VLF signals propagating in the Earth-ionosphere waveguide are used to probe the heated nighttime D region over three U.S. Navy very low frequency (VLF,3-30 kHz) transmitters. Ionospheric cooling and heating are observed when a transmitter turns off and on in the course of normal operations. Heating by the 24.0-kHz NAA transmitter in Cutler, Maine, (1000 kW radiated power) was observed by this method in 41 of 52 off/on episodes during December 1992, increasing the amplitude and retarding the phase of the 21.4-kHz NSS probe wave propagating from Annapolis, Maryland, to Gander, Newfoundland, by as much as 0.84 dB and 5.3 deg, respectively. In 6 of these 41 episodes, the amplitude of the 28.5-kHz NAU probe wave propagating from Puerto Rico to Gander was also perturbed by as much as 0.29 dB. The latter observations were unexpected due to the greater than 770 km distance between NAA and the NAU-Gander great circle path. Heating by the NSS (21.4 kHz, 265 kW) and NLK (24.8 kHz, 850 kW) transmitters was observed serendipitously in data from earlier measurements of the amplitudes of VLF signals propagating in the Earth-ionosphere waveguide. A three-dimensional model of wave absorption and electron heating in a magnetized, weakly ionized plasma is used to calculate the extent nad shape of the collision frequency (i.e., electron temperature) enhancement above a VLF transmitter. The enhancements are annular, with a geomagnetic north-south asymmetry and a radius at the outer half-maximum of the collision frequency enhancement of about 150 km. Heating by the NAA transmitter is predicted to increase the nighttime D region electron temperature by as much as a factor of 3. The calculated changes in the D region conductivity are used in a three-dimensional model of propagation in the Earth-ionosphere wavelength to predict the effect of the heated patch on a subionospheric VLF probe wave. The range of predicted scattered field amplitudes is in general consistent with the observed signal perturbations. Discrepanices in the predictions are attributed to lack of knowledge of the D region electron density profile along the probe wave great circle paths.
Ear-Canal Reflectance, Umbo Velocity and Tympanometry in Normal Hearing Adults
Rosowski, John J; Nakajima, Hideko H.; Hamade, Mohamad A.; Mafoud, Lorice; Merchant, Gabrielle R.; Halpin, Christopher F.; Merchant, Saumil N.
2011-01-01
Objective This study compares measurements of ear-canal reflectance (ECR) to other objective measurements of middle-ear function including, audiometry, umbo velocity (VU), and tympanometry in a population of strictly defined normal hearing ears. Design Data were prospectively gathered from 58 ears of 29 normal hearing subjects, 16 female and 13 male, aged 22–64 years. Subjects met all of the following criteria to be considered as having normal hearing. (1) No history of significant middle-ear disease. (2) No history of otologic surgery. (3) Normal tympanic membrane (TM) on otoscopy. (4) Pure-tone audiometric thresholds of 20 dB HL or better for 0.25 – 8 kHz. (5) Air-bone gaps no greater than 15 dB at 0.25 kHz and 10 dB for 0.5 – 4 kHz. (6) Normal, type-A peaked tympanograms. (7) All subjects had two “normal” ears (as defined by these criteria). Measurements included pure-tone audiometry for 0.25 – 8 kHz, standard 226 Hz tympanometry, Ear canal reflectance(ECR) for 0.2 – 6 kHz at 60 dB SPL using the Mimosa Acoustics HearID system, and Umbo Velocity (VU ) for 0.3 – 6 kHz at 70–90 dB SPL using the HLV-1000 laser Doppler vibrometer (Polytec Inc). Results Mean power reflectance (|ECR|2) was near 1.0 at 0.2– 0.3 kHz, decreased to a broad minimum of 0.3 to 0.4 between 1 and 4 kHz, and then sharply increased to almost 0.8 by 6 kHz. The mean pressure reflectance phase angle (∠ECR) plotted on a linear frequency scale showed a group delay of approximately 0.1 ms for 0.2 – 6 kHz. Small significant differences were observed in |ECR|2 at the lowest frequencies between right and left ears, and between males and females at 4 kHz. |ECR|2 decreased with age, but reached significance only at 1 kHz. Our ECR measurements were generally similar to previous published reports. Highly significant negative correlations were found between |ECR|2 and VU for frequencies below 1 kHz. Significant correlations were also found between the tympanometrically determined peak total compliance and |ECR|2 and The results suggest that middle-ear compliance VU at frequencies below 1 kHz. contributes significantly to the measured power reflectance and umbo velocity at frequencies below 1 kHz, but not at higher frequencies. Conclusions This study has established a database of objective measurements of middle ear function (ear-canal reflectance, umbo velocity, tympanometry) in a population of strictly defined normal hearing ears. The data will promote our understanding of normal middle ear function, and will serve as a control for comparison to similar measurements made in pathological ears. PMID:21857517
NASA Technical Reports Server (NTRS)
Wilson, P. M.; Wilson, T. G.; Owen, H. A., Jr.
1982-01-01
Dc to dc converters which operate reliably and efficiently at switching frequencies high enough to effect substantial reductions in the size and weight of converter energy storage elements are studied. A two winding current or voltage stepup (buck boost) dc-to-dc converter power stage submodule designed to operate in the 2.5-kW range, with an input voltage range of 110 to 180 V dc, and an output voltage of 250 V dc is emphasized. In order to assess the limitations of present day component and circuit technologies, a design goal switching frequency of 10 kHz was maintained. The converter design requirements represent a unique combination of high frequency, high voltage, and high power operation. The turn off dynamics of the primary circuit power switching transistor and its associated turn off snubber circuitry are investigated.
NASA Astrophysics Data System (ADS)
Wilson, P. M.; Wilson, T. G.; Owen, H. A., Jr.
Dc to dc converters which operate reliably and efficiently at switching frequencies high enough to effect substantial reductions in the size and weight of converter energy storage elements are studied. A two winding current or voltage stepup (buck boost) dc-to-dc converter power stage submodule designed to operate in the 2.5-kW range, with an input voltage range of 110 to 180 V dc, and an output voltage of 250 V dc is emphasized. In order to assess the limitations of present day component and circuit technologies, a design goal switching frequency of 10 kHz was maintained. The converter design requirements represent a unique combination of high frequency, high voltage, and high power operation. The turn off dynamics of the primary circuit power switching transistor and its associated turn off snubber circuitry are investigated.
High power VCSEL devices for atomic clock applications
NASA Astrophysics Data System (ADS)
Watkins, L. S.; Ghosh, C.; Seurin, J.-F.; Zhou, D.; Xu, G.; Xu, B.; Miglo, A.
2015-09-01
We are developing VCSEL technology producing >100mW in single frequency at wavelengths 780nm, 795nm and 850nm. Small aperture VCSELs with few mW output have found major applications in atomic clock experiments. Using an external cavity three-mirror configuration we have been able to operate larger aperture VCSELs and obtain >70mW power in single frequency operation. The VCSEL has been mounted in a fiber pigtailed package with the external mirror mounted on a shear piezo. The package incorporates a miniature Rb cell locker to lock the VCSEL wavelength. This VCSEL operates in single frequency and is tuned by a combination of piezo actuator, temperature and current. Mode-hop free tuning over >30GHz frequency span is obtained. The VCSEL has been locked to the Rb D2 line and feedback control used to obtain line-widths of <100kHz.
47 CFR 15.221 - Operation in the band 525-1705 kHz.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Operation in the band 525-1705 kHz. 15.221... kHz. (a) Carrier current systems and transmitters employing a leaky coaxial cable as the radiating antenna may operate in the band 525-1705 kHz provided the field strength levels of the radiated emissions...
47 CFR 15.221 - Operation in the band 525-1705 kHz.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Operation in the band 525-1705 kHz. 15.221... kHz. (a) Carrier current systems and transmitters employing a leaky coaxial cable as the radiating antenna may operate in the band 525-1705 kHz provided the field strength levels of the radiated emissions...
47 CFR 15.221 - Operation in the band 525-1705 kHz.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Operation in the band 525-1705 kHz. 15.221... kHz. (a) Carrier current systems and transmitters employing a leaky coaxial cable as the radiating antenna may operate in the band 525-1705 kHz provided the field strength levels of the radiated emissions...
47 CFR 15.221 - Operation in the band 525-1705 kHz.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 1 2014-10-01 2014-10-01 false Operation in the band 525-1705 kHz. 15.221... kHz. (a) Carrier current systems and transmitters employing a leaky coaxial cable as the radiating antenna may operate in the band 525-1705 kHz provided the field strength levels of the radiated emissions...
47 CFR 15.221 - Operation in the band 525-1705 kHz.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 1 2013-10-01 2013-10-01 false Operation in the band 525-1705 kHz. 15.221... kHz. (a) Carrier current systems and transmitters employing a leaky coaxial cable as the radiating antenna may operate in the band 525-1705 kHz provided the field strength levels of the radiated emissions...
Vladimirova, Irina A; Lankin, Yuri N; Philyppov, Igor B; Sushiy, Lyudmyla F; Shuba, Yaroslav M
2014-01-01
Bipolar electrosurgical tissue welding uses forceps-like electrodes for grasping the tissues and delivering high-frequency electric current (HFEC) to produce local heat, desiccation, and protein denaturation, resulting in the fusion of the contacting tissues. Although in this technique no electric current is flowing through the whole body to cause electric injury, depending on the frequency of applied energy, it may produce local excitation of intramural nerves, which can propagate beyond the surgical site potentially causing harmful effects. The effects of varying frequency of HFEC on tissue excitability in bipolar electrosurgical modality were studied in vitro using electric field stimulation (EFS) method on multicellular smooth muscle strips of rat vas deferens. Contractile response to 5-s-long sine wave EFS train was taken as the measure of excitation of intramural nerves. EFS-induced contraction consisted of phasic and tonic components. The amplitude of both components decreased with increasing frequency, with tonic component disappearing at about 10 kHz and phasic component at about 50 kHz. Because components of EFS-induced contraction depend on different neurotransmitters, this indicates that various neurotransmitter systems are characterized by distinct frequency dependence, but above 50 kHz they all become inactivated. Bipolar electrosurgical sealing of porcine gut showed no difference in the structure of seal area at HFEC of 67 and 533 kHz. EFS frequency of 50 kHz represents the upper limit for excitation. HFEC above 50 kHz is safe to use for bipolar electrosurgical tissue welding without concerns of excitation propagating beyond the surgical site. Copyright © 2014 Elsevier Inc. All rights reserved.
Detection of high-frequency energy changes in sustained vowels produced by singers
Monson, Brian B.; Lotto, Andrew J.; Ternström, Sten
2011-01-01
The human voice spectrum above 5 kHz receives little attention. However, there are reasons to believe that this high-frequency energy (HFE) may play a role in perceived quality of voice in singing and speech. To fulfill this role, differences in HFE must first be detectable. To determine human ability to detect differences in HFE, the levels of the 8- and 16-kHz center-frequency octave bands were individually attenuated in sustained vowel sounds produced by singers and presented to listeners. Relatively small changes in HFE were in fact detectable, suggesting that this frequency range potentially contributes to the perception of especially the singing voice. Detection ability was greater in the 8-kHz octave than in the 16-kHz octave and varied with band energy level. PMID:21476681
Echolocation signals and transmission beam pattern of a false killer whale (Pseudorca crassidens).
Au, W W; Pawloski, J L; Nachtigall, P E; Blonz, M; Gisner, R C
1995-07-01
The echolocation transmission beam pattern of a false killer whale (Pseudorca crassidens) was measured in the vertical and horizontal planes. A vertical array of seven broadband miniature hydrophones was used to measure the beam pattern in the vertical plane and a horizontal array of the same hydrophones was used in the horizontal plane. The measurements were performed in the open waters of Kaneohe Bay, Oahu, Hawaii, while the whale performed a target discrimination task. Four types of signals, characterized by their frequency spectra, were measured. Type-1 signals had a single low-frequency peak at 40 +/- 9 kHz and a low-amplitude shoulder at high frequencies. Type-2 signals had a bimodal frequency characteristic with a primary peak at 46 +/- 7 kHz and a secondary peak at 88 +/- 13 kHz. Type-3 signals were also bimodal but with a primary peak at 100 +/- 7 kHz and a secondary peak at 49 +/- 9 kHz. Type-4 signals had a single high-frequency peak at 104 +/- 7 kHz. The center frequency of the signals were found to be linearly correlated to the peak-to-peak source level, increasing with increasing source level. The major axis of the vertical beam was directed slightly downward between 0 and -5 degrees, in contrast to the +5 to 10 degrees for Tursiops and Delphinapterus. The beam in the horizontal plane was directed forward between 0 degrees and -5 degrees.(ABSTRACT TRUNCATED AT 250 WORDS)
Channel Equalization for Single Carrier MIMO Underwater Acoustic Communications
2010-01-01
II Tx 1 Tx 2 Symbol mapping s1 s2 x1 x2 sa Figure 2: Signalling at the transmitter in Makai05 experiment. fc = 32 kHz and the symbol interval was...frequency was fc = 37.5 kHz and the symbol interval was 0.05ms. The occupied channel bandwidth was fb = 25 kHz due to a pulse shaping filter with roll...water. QPSK modulation was used with a symbol rate of 4 ksps. The carrier frequency was fc = 17 kHz. The structure of the transmission packet is
Ibsen, Stuart D; Nachtigall, Paul E; Krause-Nehring, Jacqueline; Kloepper, Laura; Breese, Marlee; Li, Songhai; Vlachos, Stephanie
2012-08-01
A two-dimensional array of 16 hydrophones was created to map the spatial distribution of different frequencies within the echolocation beam of a Tursiops truncatus and a Pseudorca crassidens. It was previously shown that both the Tursiops and Pseudorca only paid attention to frequencies between 29 and 42 kHz while echolocating. Both individuals tightly focused the 30 kHz frequency and the spatial location of the focus was consistently pointed toward the target. At 50 kHz the beam was less focused and less precisely pointed at the target. At 100 kHz the focus was often completely lost and was not pointed at the target. This indicates that these individuals actively focused the beam toward the target only in the frequency range they paid attention to. Frequencies outside this range were left unfocused and undirected. This focusing was probably achieved through sensorimotor control of the melon morphology and nasal air sacs. This indicates that both morphologically different species can control the spatial distribution of different frequency ranges within the echolocation beam to create consistent ensonation of desired targets.
A CMOS power-efficient low-noise current-mode front-end amplifier for neural signal recording.
Wu, Chung-Yu; Chen, Wei-Ming; Kuo, Liang-Ting
2013-04-01
In this paper, a new current-mode front-end amplifier (CMFEA) for neural signal recording systems is proposed. In the proposed CMFEA, a current-mode preamplifier with an active feedback loop operated at very low frequency is designed as the first gain stage to bypass any dc offset current generated by the electrode-tissue interface and to achieve a low high-pass cutoff frequency below 0.5 Hz. No reset signal or ultra-large pseudo resistor is required. The current-mode preamplifier has low dc operation current to enhance low-noise performance and decrease power consumption. A programmable current gain stage is adopted to provide adjustable gain for adaptive signal scaling. A following current-mode filter is designed to adjust the low-pass cutoff frequency for different neural signals. The proposed CMFEA is designed and fabricated in 0.18-μm CMOS technology and the area of the core circuit is 0.076 mm(2). The measured high-pass cutoff frequency is as low as 0.3 Hz and the low-pass cutoff frequency is adjustable from 1 kHz to 10 kHz. The measured maximum current gain is 55.9 dB. The measured input-referred current noise density is 153 fA /√Hz , and the power consumption is 13 μW at 1-V power supply. The fabricated CMFEA has been successfully applied to the animal test for recording the seizure ECoG of Long-Evan rats.
NASA Astrophysics Data System (ADS)
Shi, Qiongfeng; Wang, Tao; Kobayashi, Takeshi; Lee, Chengkuo
2016-05-01
Acoustic energy transfer (AET) has been widely used for contactless energy delivery to implantable devices. However, most of the energy harvesters (ultrasonic receivers) for AET are macro-scale transducers with large volume and limited operation bandwidth. Here, we propose and investigate two microelectromechanical systems diaphragm based piezoelectric ultrasonic energy harvesters (PUEHs) as an alternative for AET. The proposed PUEHs consist of micro-scale diaphragm array with different geometric parameter design. Diaphragms in PUEH-1 have large length to width ratio to achieve broadband property, while its energy harvesting performance is compromised. Diaphragms in PUEH-2 have smaller length to width ratio and thinner thickness to achieve both broadband property and good energy harvesting performance. Both PUEHs have miniaturized size and wide operation bandwidth that are ideally suitable to be integrated as power source for implantable biomedical devices. PUEH-1 has a merged -6 dB bandwidth of 74.5% with a central frequency of 350 kHz. PUEH-2 has two separate -6 dB bandwidth of 73.7%/30.8% with central frequencies of 285 kHz/650 kHz. They can adapt to various ultrasonic sources with different working frequency spectrum. Maximum output power is 34.3 nW and 84.3 nW for PUEH-1 and PUEH-2 at 1 mW/cm2 ultrasound intensity input, respectively. The associated power density is 0.734 μW/cm2 and 4.1 μW/cm2, respectively. Better energy harvesting performance is achieved for PUEH-2 because of the optimized length to width ratio and thickness design. Both PUEHs offer more alignment flexibility with more than 40% power when they are in the range of the ultrasound transmitter.
Underwater hearing sensitivity of a male and a female Steller sea lion (Eumetopias jubatus).
Kastelein, Ronald A; van Schie, Robbert; Verboom, Wim C; de Haan, Dick
2005-09-01
The unmasked underwater hearing sensitivities of an 8-year-old male and a 7-year-old female Steller sea lion were measured in a pool, by using behavioral psychophysics. The animals were trained with positive reinforcement to respond when they detected an acoustic signal and not to respond when they did not. The signals were narrow-band, frequency-modulated stimuli with a duration of 600 ms and center frequencies ranging from 0.5 to 32 kHz for the male and from 4 to 32 kHz for the female. Detection thresholds at each frequency were measured by varying signal amplitude according to the up-down staircase method. The resulting underwater audiogram (50% detection thresholds) for the male Steller sea lion showed the typical mammalian U-shape. His maximum sensitivity (77 dB re: 1 microPa, rms) occurred at 1 kHz. The range of best hearing (10 dB from the maximum sensitivity) was from 1 to 16 kHz (4 octaves). Higher hearing thresholds (indicating poorer sensitivity) were observed below 1 kHz and above 16 kHz. The maximum sensitivity of the female (73 dB re: 1 microPa, rms) occurred at 25 kHz. Higher hearing thresholds (indicating poorer sensitivity) were observed for signals below 16 kHz and above 25 kHz. At frequencies for which both subjects were tested, hearing thresholds of the male were significantly higher than those of the female. The hearing sensitivity differences between the male and female Steller sea lion in this study may be due to individual differences in sensitivity between the subjects or due to sexual dimorphism in hearing.
47 CFR 95.637 - Modulation standards.
Code of Federal Regulations, 2012 CFR
2012-10-01
... frequency deviation of plus or minus 2.5 kHz, and the audio frequency response must not exceed 3.125 kHz..., must automatically prevent a greater than normal audio level from causing overmodulation. The transmitter also must include audio frequency low pass filtering, unless it complies with the applicable...
47 CFR 95.637 - Modulation standards.
Code of Federal Regulations, 2011 CFR
2011-10-01
... frequency deviation of plus or minus 2.5 kHz, and the audio frequency response must not exceed 3.125 kHz..., must automatically prevent a greater than normal audio level from causing overmodulation. The transmitter also must include audio frequency low pass filtering, unless it complies with the applicable...
47 CFR 95.637 - Modulation standards.
Code of Federal Regulations, 2014 CFR
2014-10-01
... frequency deviation of plus or minus 2.5 kHz, and the audio frequency response must not exceed 3.125 kHz..., must automatically prevent a greater than normal audio level from causing overmodulation. The transmitter also must include audio frequency low pass filtering, unless it complies with the applicable...
47 CFR 95.637 - Modulation standards.
Code of Federal Regulations, 2013 CFR
2013-10-01
... frequency deviation of plus or minus 2.5 kHz, and the audio frequency response must not exceed 3.125 kHz..., must automatically prevent a greater than normal audio level from causing overmodulation. The transmitter also must include audio frequency low pass filtering, unless it complies with the applicable...
47 CFR 80.375 - Radiodetermination frequencies.
Code of Federal Regulations, 2010 CFR
2010-10-01
... channels in the 285-325 kHz band are assignable to ship stations for cable-repair radiodetermination... kHz band. The conditions of use of these channels are set forth in subpart X of this part. Channel... frequency bands above 2400 MHz. (1) The radiodetermination frequency bands assignable to ship and shore...
A 2.5 kW cascaded Schwarz converter for 20 kHz power distribution
NASA Technical Reports Server (NTRS)
Shetler, Russell E.; Stuart, Thomas A.
1989-01-01
Because it avoids the high currents in a parallel loaded capacitor, the cascaded Schwarz converter should offer better component utilization than converters with sinusoidal output voltages. The circuit is relatively easy to protect, and it provides a predictable trapezoidal voltage waveform that should be satisfactory for 20-kHz distribution systems. Analysis of the system is enhanced by plotting curves of normalized variables vs. gamma(1), where gamma(1) is proportional to the variable frequency of the first stage. Light-load operation is greatly improved by the addition of a power recycling rectifier bridge that is back biased at medium to heavy loads. Operation has been verified on a 2.5-kW circuit that uses input and output voltages in the same range as those anticipated for certain future spacecraft power systems.
A 140 GHz pulsed EPR/212 MHz NMR spectrometer for DNP studies
NASA Astrophysics Data System (ADS)
Smith, Albert A.; Corzilius, Björn; Bryant, Jeffrey A.; DeRocher, Ronald; Woskov, Paul P.; Temkin, Richard J.; Griffin, Robert G.
2012-10-01
We described a versatile spectrometer designed for the study of dynamic nuclear polarization (DNP) at low temperatures and high fields. The instrument functions both as an NMR spectrometer operating at 212 MHz (1H frequency) with DNP capabilities, and as a pulsed-EPR operating at 140 GHz. A coiled TE011 resonator acts as both an NMR coil and microwave resonator, and a double balanced (1H, 13C) radio frequency circuit greatly stabilizes the NMR performance. A new 140 GHz microwave bridge has also been developed, which utilizes a four-phase network and ELDOR channel at 8.75 GHz, that is then multiplied and mixed to obtain 140 GHz microwave pulses with an output power of 120 mW. Nutation frequencies obtained are as follows: 6 MHz on S = 1/2 electron spins, 100 kHz on 1H, and 50 kHz on 13C. We demonstrate basic EPR, ELDOR, ENDOR, and DNP experiments here. Our solid effect DNP results demonstrate an enhancement of 144 and sensitivity gain of 310 using OX063 trityl at 80 K and an enhancement of 157 and maximum sensitivity gain of 234 using Gd-DOTA at 20 K, which is significantly better performance than previously reported at high fields (⩾3 T).
A 140 GHz Pulsed EPR/212 MHz NMR Spectrometer for DNP Studies
Smith, Albert A.; Corzilius, Björn; Bryant, Jeffrey A.; DeRocher, Ronald; Woskov, Paul P.; Temkin, Richard J.; Griffin, Robert G.
2012-01-01
We described a versatile spectrometer designed for the study of dynamic nuclear polarization (DNP) at low temperatures and high fields. The instrument functions both as an NMR spectrometer operating at 212 MHz (1H frequency) with DNP capabilities, and as a pulsed-EPR operating at 140 GHz. A coiled TE011 resonator acts as both an NMR coil and microwave resonator, and a double balanced (1H, 13C) radio frequency circuit greatly stabilizes the NMR performance. A new 140 GHz microwave bridge has also been developed, which utilizes a four-phase network and ELDOR channel at 8.75 GHz, that is then multiplied and mixed to obtain 140 GHz microwave pulses with an output power of 120 mW. Nutation frequencies obtained are as follows: 6 MHz on S = ½ electron spins, 100 kHz on 1H, and 50 kHz on 13C. We demonstrate basic EPR, ELDOR, ENDOR, and DNP experiments here. Our solid effect DNP results demonstrate an enhancement of 144 and sensitivity gain of 310 using OX063 trityl at 80 K and an enhancement of 157 and maximum sensitivity gain of 234 using Gd-DOTA at 20 K, which is significantly better performance than previously reported at high fields (>3 T). PMID:22975246
Piezohydraulic Pump Development
NASA Technical Reports Server (NTRS)
Lynch, Christopher S.
2005-01-01
Reciprocating piston piezohydraulic pumps were developed originally under the Smart Wing Phase II program (Lynch) and later under the CHAP program (CSA, Kinetic Ceramics). These pumps focused on 10 cm scale stack actuators operating below resonance and, more recently, at resonance. A survey of commercially available linear actuators indicates that obtaining power density and specific power greater than electromagnetic linear actuators requires driving the stacks at frequencies greater than 1 KHz at high fields. In the case of 10 cm scale actuators the power supply signal conditioning becomes large and heavy and the soft PZT stack actuators generate a lot of heat due to internal losses. Reciprocation frequencies can be increased and material losses significantly decreased through use of millimeter scale single crystal stack actuators. We are presently targeting the design of pumps that utilize stacks at the 1-10 mm length scale and run at reciprocating frequencies of 20kHz or greater. This offers significant advantages over current approaches including eliminating audible noise and significantly increasing the power density and specific power of the system (including electronics). The pump currently under development will comprise an LC resonant drive of a resonant crystal and head mass operating against a resonant fluid column. Each of these resonant systems are high Q and together should produce a single high Q second order system.
47 CFR 15.217 - Operation in the band 160-190 kHz.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Operation in the band 160-190 kHz. 15.217... Intentional Radiators Radiated Emission Limits, Additional Provisions § 15.217 Operation in the band 160-190 k... lead (if used) shall not exceed 15 meters. (c) All emissions below 160 kHz or above 190 kHz shall be...
47 CFR 15.217 - Operation in the band 160-190 kHz.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Operation in the band 160-190 kHz. 15.217... Intentional Radiators Radiated Emission Limits, Additional Provisions § 15.217 Operation in the band 160-190 k... lead (if used) shall not exceed 15 meters. (c) All emissions below 160 kHz or above 190 kHz shall be...
47 CFR 15.217 - Operation in the band 160-190 kHz.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 1 2013-10-01 2013-10-01 false Operation in the band 160-190 kHz. 15.217... Intentional Radiators Radiated Emission Limits, Additional Provisions § 15.217 Operation in the band 160-190 k... lead (if used) shall not exceed 15 meters. (c) All emissions below 160 kHz or above 190 kHz shall be...
47 CFR 15.217 - Operation in the band 160-190 kHz.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 1 2014-10-01 2014-10-01 false Operation in the band 160-190 kHz. 15.217... Intentional Radiators Radiated Emission Limits, Additional Provisions § 15.217 Operation in the band 160-190 k... lead (if used) shall not exceed 15 meters. (c) All emissions below 160 kHz or above 190 kHz shall be...
47 CFR 15.217 - Operation in the band 160-190 kHz.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Operation in the band 160-190 kHz. 15.217... Intentional Radiators Radiated Emission Limits, Additional Provisions § 15.217 Operation in the band 160-190 k... lead (if used) shall not exceed 15 meters. (c) All emissions below 160 kHz or above 190 kHz shall be...
Impulse noise generator--design and operation.
Brinkmann, H
1991-01-01
In the seventies PFANDER (Pfander, 1975) proposed a screening test with an impulse noise simulator to check the particular responsivity of soldiers on vulnerability of the inner ear concerning the impulse noise-induced hearing loss. According to a system developed at the University of Oldenburg (Germany) (Klug & Radek, 1987), we have constructed an impulse noise generator designed for our specific requirements that will be presented. The simulator consists of an electrical ignited impulse noise spark gap which is supplied by a 3.5 kV high voltage source. At a distance of 1.10 m from the center of the impulse noise spark gap a peak pressure level of 155 dB with a C-Duration (Pfander, 1975) of .2 msec and with the main energy in the frequency range from 1 kHz to 2 kHz was good reproducible. It would be preferable to shift the impulse noise spectrum to lower frequencies but experimental effort has failed so far.
Annealing effects on magnetic properties of silicone-coated iron-based soft magnetic composites
NASA Astrophysics Data System (ADS)
Wu, Shen; Sun, Aizhi; Zhai, Fuqiang; Wang, Jin; Zhang, Qian; Xu, Wenhuan; Logan, Philip; Volinsky, Alex A.
2012-03-01
This paper focuses on novel iron-based soft magnetic composites synthesis utilizing high thermal stability silicone resin to coat iron powder. The effect of an annealing treatment on the magnetic properties of synthesized magnets was investigated. The coated silicone insulating layer was characterized by scanning electron microscopy and energy dispersive X-ray spectroscopy. Silicone uniformly coated the powder surface, resulting in a reduction of the imaginary part of the permeability, thereby increasing the electrical resistivity and the operating frequency of the synthesized magnets. The annealing treatment increased the initial permeability, the maximum permeability, and the magnetic induction, and decreased the coercivity. Annealing at 580 °C increased the maximum permeability by 72.5%. The result of annealing at 580 °C shows that the ferromagnetic resonance frequency increased from 2 kHz for conventional epoxy resin coated samples to 80 kHz for the silicone resin insulated composites.
Development of a long-gauge vibration sensor
NASA Astrophysics Data System (ADS)
Kung, Peter; Comanici, Maria I.; Li, Qian; Zhang, Yiwei
2015-03-01
We have recently found that a long length of fiber of up to 1 km terminated with an in-fiber cavity structure can detect vibrations over a frequency range from 5 Hz to 2 kHz. We want to determine whether the sensor (including packaging) can be optimized to detect vibrations at even higher frequencies. The structure can be used as a distributed vibration sensor mounted on large motors and other rotating machines to capture the entire frequency spectrum of the associated vibration signals, and therefore, replace the many accelerometers, which add to maintenance cost. The sensor may also help detect in-slot vibrations which cause intermittent contact leading to sparking under high voltages inside air-cooled generators. However, that requires the sensor to detect frequencies associated with vibration sparking, ranging from 6 kHz to 15 kHz. Acoustic vibration monitoring may need sensing at even higher frequencies (30 kHz to 150 kHz) associated with partial discharge (PD) in generators and transformers. Detecting lower frequencies in the range 2 Hz to 200 Hz makes the sensor suitable for seismic studies and falls well into the vibrations associated with rotating machines. Another application of interest is corrosion detection in large re-enforced concrete structures by inserting the sensor along a long hole drilled around structures showing signs of corrosion. The frequency response for the proposed longgauge vibration sensor depends on packaging.
NASA Astrophysics Data System (ADS)
Yesudas, Freeda; Mero, Mark; Kneipp, Janina; Heiner, Zsuzsanna
2018-03-01
Broadband vibrational sum-frequency generation (BB-VSFG) spectroscopy has become a well-established surface analytical tool capable of identifying the orientation and structure of molecular layers. A straightforward way to boost the sensitivity of the technique could be to increase the laser repetition rate beyond that of standard BB-VSFG spectrometers, which rely on Ti:sapphire lasers operating at repetition rates of 1-5 kHz. Nevertheless, possible thermally induced artifacts in the vibrational spectra due to higher laser average powers are unexplored. Here, we discuss laser power induced temperature accumulation effects that distort the BB-VSFG spectra of 1,2-diacyl-sn-glycero-3-phosphocholine at an interface between two transparent phases at repetition rates of 5, 10, 50, and 100 kHz at constant pulse energy. No heat-induced distortions were found in the spectra, suggesting that the increase in the laser repetition rate provides a feasible route to an improved signal-to-noise ratio or shorter data acquisition times in BB-VSFG spectroscopy for thin films on transparent substrates. The results have implications for future BB-VSFG spectrometers pushing the detection limit for molecular layers with low surface coverage.
Search for inversion splitting in the 3ν2 band of phosphine
NASA Astrophysics Data System (ADS)
Okuda, Shoko; Sasada, Hiroyuki
2018-04-01
Sub-Doppler resolution spectroscopy of the 3ν2 band of phosphine has been carried out using a difference-frequency-generation source referenced to an optical frequency comb and a cavity-enhanced absorption cell. Three Q-branch transitions are recorded with a linewidth of 150 kHz, but no inversion splitting is observed even though it was predicted 300 kHz in Journal of Chemical Physics, vol. 145, art. No. 091102 (2016). Transition frequencies of six Q-branch transitions have been determined with an uncertainty of 6-16 kHz.
Four-choice sound localization abilities of two Florida manatees, Trichechus manatus latirostris.
Colbert, Debborah E; Gaspard, Joseph C; Reep, Roger; Mann, David A; Bauer, Gordon B
2009-07-01
The absolute sound localization abilities of two Florida manatees (Trichechus manatus latirostris) were measured using a four-choice discrimination paradigm, with test locations positioned at 45 deg., 90 deg., 270 deg. and 315 deg. angles relative to subjects facing 0 deg. Three broadband signals were tested at four durations (200, 500, 1000, 3000 ms), including a stimulus that spanned a wide range of frequencies (0.2-20 kHz), one stimulus that was restricted to frequencies with wavelengths shorter than their interaural time distances (6-20 kHz) and one that was limited to those with wavelengths longer than their interaural time distances (0.2-2 kHz). Two 3000 ms tonal signals were tested, including a 4 kHz stimulus, which is the midpoint of the 2.5-5.9 kHz fundamental frequency range of manatee vocalizations and a 16 kHz stimulus, which is in the range of manatee best-hearing sensitivity. Percentage correct within the broadband conditions ranged from 79% to 93% for Subject 1 and from 51% to 93% for Subject 2. Both performed above chance with the tonal signals but had much lower accuracy than with broadband signals, with Subject 1 at 44% and 33% and Subject 2 at 49% and 32% at the 4 kHz and 16 kHz conditions, respectively. These results demonstrate that manatees are able to localize frequency bands with wavelengths that are both shorter and longer than their interaural time distances and suggest that they have the ability to localize both manatee vocalizations and recreational boat engine noises.
Follow-up of hearing thresholds among forge hammering workers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kamal, A.A.; Mikael, R.A.; Faris, R.
Hearing threshold was reexamined in a group of forge hammering workers investigated 8 years ago with consideration of the age effect and of auditory symptoms. Workers were exposed to impact noise that ranged from 112 to 139 dB(A)--at an irregular rate of 20 to 50 drop/minute--and a continuous background noise that ranged from 90 to 94 dB(A). Similar to what was observed 8 years ago, the present permanent threshold shift (PTS) showed a maximum notch at the frequency of 6 kHz and considerable elevations at the frequencies of 0.25-1 kHz. The age-corrected PTS and the postexposure hearing threshold were significantlymore » higher than the corresponding previous values at the frequencies 0.25, 0.5, 1, and 8 kHz only. The rise was more evident at the low than at the high frequencies. Temporary threshold shift (TTS) values were significantly less than those 8 years ago. Contrary to the previous TTS, the present TTS were higher at low than at high frequencies. Although progression of PTS at the frequencies 0.25 and 0.5 kHz was continuous throughout the observed durations of exposure, progression at higher frequencies occurred essentially in the first 10 to 15 years of exposure. Thereafter, it followed a much slower rate. Tinnitus was significantly associated with difficulty in hearing the human voice and with elevation of PTS at all the tested frequencies, while acoustic after-image was significantly associated with increment of PTS at the frequencies 0.25-2 kHz. No relation between PTS and smoking was found. PTS at low frequencies may provide an indication of progression of hearing damage when the sensitivity at 6 and 4 kHz diminishes after prolonged years of exposure. Tinnitus and acoustic after-image are related to the auditory effect of forge hammering noise.« less
A micromachined efficient parametric array loudspeaker with a wide radiation frequency band.
Je, Yub; Lee, Haksue; Been, Kyounghun; Moon, Wonkyu
2015-04-01
Parametric array (PA) loudspeakers generate directional audible sound via the PA effect, which can make private listening possible. The practical applications of PA loudspeakers include information technology devices that require large power efficiency transducers with a wide frequency bandwidth. Piezoelectric micromachined ultrasonic transducers (PMUTs) are compact and efficient units for PA sources [Je, Lee, and Moon, Ultrasonics 53, 1124-1134 (2013)]. This study investigated the use of an array of PMUTs to make a PA loudspeaker with high power efficiency and wide bandwidth. The achievable maximum radiation bandwidth of the driver was calculated, and an array of PMUTs with two distinct resonance frequencies (f1 = 100 kHz, f2 = 110 kHz) was designed. Out-of-phase driving was used with the dual-resonance transducer array to increase the bandwidth. The fabricated PMUT array exhibited an efficiency of up to 71%, together with a ±3-dB bandwidth of 17 kHz for directly radiated primary waves, and 19.5 kHz (500 Hz to 20 kHz) for the difference frequency waves (with equalization).
NASA Astrophysics Data System (ADS)
Mamun, Md Abdullah Al; Furuta, Hiroshi; Hatta, Akimitsu
2018-06-01
Hydrogenated amorphous carbon (a-C:H) films are deposited on silicon (Si) substrates using a high-repetition microsecond-pulsed DC plasma chemical vapor deposition (CVD) system from acetylene (C2H2) at a gas pressure of 15 Pa inside a custom-made vacuum chamber. The plasma discharge characteristics, hydrocarbon species, and the microstructure of the resulting films are examined at various pulse repetition rates from 50 to 400 kHz and a fixed duty cycle of 50%. The optical emission spectra confirmed the increase in electron excitation energy from 1.09 to 1.82 eV and the decrease in the intensity ratio of CH/C2 from 1.04 to 0.75 with increasing pulse frequency, indicating the enhanced electron impact dissociation of C2H2 gas. With increasing pulse frequency, the deposition rate gradually increased, reaching a maximum rate of 60 nm/min at 200 kHz, after which a progressive decrease was noted, whereas the deposition area was almost uniform for all the prepared films. Clear trends of increasing sp3 content (amorphization) and decreasing hydrogen (H) content in the films were observed as the pulse repetition rate increased, while most of the hydrogen atoms bonded to carbon atoms by sp3 hybridization rather than by sp2 hybridization.
Continuous exposure to low-frequency noise and carbon disulfide: Combined effects on hearing.
Venet, Thomas; Carreres-Pons, Maria; Chalansonnet, Monique; Thomas, Aurélie; Merlen, Lise; Nunge, Hervé; Bonfanti, Elodie; Cosnier, Frédéric; Llorens, Jordi; Campo, Pierre
2017-09-01
Carbon disulfide (CS 2 ) is used in industry; it has been shown to have neurotoxic effects, causing central and distal axonopathies.However, it is not considered cochleotoxic as it does not affect hair cells in the organ of Corti, and the only auditory effects reported in the literature were confined to the low-frequency region. No reports on the effects of combined exposure to low-frequency noise and CS 2 have been published to date. This article focuses on the effects on rat hearing of combined exposure to noise with increasing concentrations of CS 2 (0, 63,250, and 500ppm, 6h per day, 5 days per week, for 4 weeks). The noise used was a low-frequency noise ranging from 0.5 to 2kHz at an intensity of 106dB SPL. Auditory function was tested using distortion product oto-acoustic emissions, which mainly reflects the cochlear performances. Exposure to noise alone caused an auditory deficit in a frequency area ranging from 3.6 to 6 kHz. The damaged area was approximately one octave (6kHz) above the highest frequency of the exposure noise (2.8kHz); it was a little wider than expected based on the noise spectrum.Consequently, since maximum hearing sensitivity is located around 8kHz in rats, low-frequency noise exposure can affect the cochlear regions detecting mid-range frequencies. Co-exposure to CS 2 (250-ppm and over) and noise increased the extent of the damaged frequency window since a significant auditory deficit was measured at 9.6kHz in these conditions.Moreover, the significance at 9.6kHz increased with the solvent concentrations. Histological data showed that neither hair cells nor ganglion cells were damaged by CS 2 . This discrepancy between functional and histological data is discussed. Like most aromatic solvents, carbon disulfide should be considered as a key parameter in hearing conservation régulations. Copyright © 2017 Elsevier B.V. All rights reserved.
Fully developed turbulence and complex time singularities
NASA Astrophysics Data System (ADS)
Dombre, T.; Gagne, Y.; Hopfinger, E.
The hypothesis of Frisch and Morf (1981), relating intermittent bursts observed in high-pass-filtered turbulent-flow data to complex time singularities in the solution of the Navier-Stokes equations, is tested experimentally. Velocity signals filtered at high-pass frequency 1 kHz and low-pass frequency 6 kHz are recorded for 7 min at sampling frequency 20 kHz in a flow of mean velocity 6.1 m/s, with mesh length d = 7.5 cm, observation point x/d = 40, R sub lambda = 67, dissipation length eta = 0.5 mm, and Kolmogorov frequency fK = about 2 kHz. The results are presented in graphs, and it is shown that the exponential behavior of the energy spectrum settles well before fK, the spectra of individual bursts having exponential behavior and delta(asterisk) values consistent with the Frisch-Morf hypothesis, at least for high-amplitude events.
Underwater audiogram of the California sea lion by the conditioned vocalization technique1
Schusterman, Ronald J.; Balliet, Richard F.; Nixon, James
1972-01-01
Conditioning techniques were developed demonstrating that pure tone frequencies under water can exert nearly perfect control over the underwater click vocalizations of the California sea lion (Zalophus californianus). Conditioned vocalizations proved to be a reliable way of obtaining underwater sound detection thresholds in Zalophus at 13 different frequencies, covering a frequency range of 250 to 64,000 Hz. The audiogram generated by these threshold measurements suggests that under water, the range of maximal sensitivity for Zalophus lies between one and 28 kHz with best sensitivity at 16 kHz. Between 28 and 36 kHz there is a loss in sensitivity of 60 dB/octave. However, with relatively intense acoustic signals (> 38 dB re 1 μb underwater), Zalophus will respond to frequencies at least as high as 192 kHz. These results are compared with the underwater hearing of other marine mammals. ImagesFig. 1. PMID:5033891
NASA Astrophysics Data System (ADS)
Popescu, Gheorghe
2001-06-01
An international frequency comparison was carried out at the Bundesamt fuer Eich- und Vermessungswessen (BEV), Vienna, within the framework of the EUROMET Project #498 from August 29 to September 5, 1999. The frequency differences obtained when the RO.1 laser from the National Institute for Laser, Plasma and Radiation Physics (NILPRP), Romania, was compared with five lasers from Austria (BEV1), Czech Republic (PLD1), France (BIPM3), Poland (GUM1) and Hungary (OMH1) are reported. Frequency differences were computed by using the matrix determinations for the group d, e, f, g. Considering the frequency differences measured for a group of three lasers compared to each other, we call the closing frequency the difference between measured and expected frequency difference (resulting from the previous two measurements). For the RO1 laser, when the BIPM3 laser was the reference laser, the closing frequencies range from +8.1 kHz to - 3.8 kHz. The relative Allan standard deviation was used to express the frequency stability and resulted 3.8 parts in 1012 for 100 s sampling time and 14000 s duration of the measurements. The averaged offset frequency relative to the BIPM4 stationary laser was 5.6 kHz and the standard deviation was 9.9 kHz.
Amano, Hikaru; Ogawa, Hidekuni; Maki, Hiromichi; Tsukamoto, Sosuke; Yonezawa, Yoshiharu; Hahn, Allen W; Caldwell, W Morton
2011-01-01
We have been searching for a suitable frequency range for an electrical impedance measurement infusion solution drip monitoring system, which we have previously reported. This electrical impedance, which is formed between two electrodes wrapped around the infusion supply polyvinyl-chloride tube and around the drip chamber, is changed by the growth and fall of each drop of fluid. Thus, the drip rate can be detected by measuring this impedance. However, many different kinds of infusion solutions such as glucose, amino acid, soya oil, and lactated Ringers solution are used in hospitals and care facilities. Therefore, it was necessary to find a suitable frequency for driving the capacitance-change sensor with a wide range of infusion solutions. In this study, the sensor electrical impedance change of 16 infusion solutions was measured from 1 kHz up to 1 MHz. The drip impedance produced by 5% glucose solution, 10% glucose solution and soya oil indicated the maximum sensor output change at 10 kHz, 20 kHz, and 70 kHz, respectively. The other 13 infusion solutions increased up to 10 kHz, and were constant from 10 kHz to 1 MHz. However, the growth, fall, and drip rate of the drops of all the infusion solutions were monitored by measuring the impedance change from 10 kHz to 30 kHz. Our experimental results indicated that most suitable excitation range for the infusion monitoring system is from 10 kHz to 30 kHz. Thus, we can now fine-tune the system for optimal sensing.
Code of Federal Regulations, 2011 CFR
2011-10-01
... international flight operations on the Major World Air Route Areas (MWARA's), as defined in the international... 11330.0 5493.0 13273.0 5652.0 13288.0 5658.0 13294.0 6559.0 17961.0 6574.0 (13) Indian Ocean (INO): kHz... aircraft stations anywhere in the world for control of the regularity and efficiency of flight and safety...
Code of Federal Regulations, 2013 CFR
2013-10-01
... international flight operations on the Major World Air Route Areas (MWARA's), as defined in the international... 11330.0 5493.0 13273.0 5652.0 13288.0 5658.0 13294.0 6559.0 17961.0 6574.0 (13) Indian Ocean (INO): kHz... aircraft stations anywhere in the world for control of the regularity and efficiency of flight and safety...
Code of Federal Regulations, 2012 CFR
2012-10-01
... international flight operations on the Major World Air Route Areas (MWARA's), as defined in the international... 11330.0 5493.0 13273.0 5652.0 13288.0 5658.0 13294.0 6559.0 17961.0 6574.0 (13) Indian Ocean (INO): kHz... aircraft stations anywhere in the world for control of the regularity and efficiency of flight and safety...
47 CFR 80.223 - Special requirements for survival craft stations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Special requirements for survival craft... requirements for survival craft stations. (a) Survival craft stations capable of transmitting on: (1) 2182 kHz... operate with A3E or A3N emission. (b) Survival craft stations must be able to receive the frequency and...
operation in a DC-DC power converter switching at a frequency of up to 15 kHz. Calculations also estimated the effect of solder layers on temperature in the device....Thermal simulations were used to calculate temperatures in a silicon carbide (SiC) Insulated -Gate Bipolar Transistor (IGBT),simulating device
47 CFR 2.1515 - Spectral measurements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Radiobeacons (EPIRBs) Environmental and Operational Test Procedures § 2.1515 Spectral measurements. (a) Set-up... controls as follows: I.F. bandwidth: 10 kHz Video filter: OFF or as wide as possible Scan time: 100 ms./div. Amplitude scale: 10 dB/div. Scan width: 20 Hz/div. Center frequency: 121.5 MHz Step (3) Record the signal...
47 CFR 90.621 - Selection and assignment of frequencies.
Code of Federal Regulations, 2014 CFR
2014-10-01
... channel(s) for which authorization for commercial use is sought that operate within 25 kHz of the center...-channel station that has been granted channel exclusivity and authorized 1 kW ERP on any of the following... been granted channel exclusivity and authorized 1 kW ERP on any of the following mountaintop sites...
47 CFR 90.621 - Selection and assignment of frequencies.
Code of Federal Regulations, 2013 CFR
2013-10-01
... channel(s) for which authorization for commercial use is sought that operate within 25 kHz of the center...-channel station that has been granted channel exclusivity and authorized 1 kW ERP on any of the following... been granted channel exclusivity and authorized 1 kW ERP on any of the following mountaintop sites...
Testing Fundamental Properties of Space with the Fermilab Holometer
Kamai, Brittany
2017-06-01
Precision length measurements provide valuable insights about the fundamental properties of space-time. The Holometer is a research program to both experimentally probe signatures of the Planck scale and to extend the accessible frequency range from kHz up to MHz for gravitational wave searches. The instrument consists of separate yet identical 39-meter Michelson interferometers operated at Fermi National Accelerator Laboratory, which can reach length sensitivities better thanmore » $${10}^{-20}\\mathrm{m/}\\sqrt{\\mathrm{Hz}}$$ within the 1-10 MHz frequency range. Lastly, the Holometer is fully operational with 130 of hours of science quality data obtained during the first observational campaign.« less
Kunimoto, Yasuomi; Hasegawa, Kensaku; Arii, Shiro; Kataoka, Hideyuki; Yazama, Hiroaki; Kuya, Junko; Kitano, Hiroya
2014-04-01
Numerous studies have reported sound-induced motion of the tympanic membrane (TM). To demonstrate sequential motion characteristics of the entire TM by noncontact laser Doppler vibrometry (LDV), we have investigated multipoint TM measurement. A laser Doppler vibrometer was mounted on a surgical microscope. The velocity was measured at 33 points on the TM using noncontact LDV without any reflectors. Measurements were performed with tonal stimuli of 1, 3, and 6 kHz. Amplitudes were calculated from these measurements, and time-dependent changes in TM motion were described using a graphics application. TM motions were detected more clearly and stably at 1 and 3 kHz than at other frequencies. This is because the external auditory canal acted as a resonant tube near 3 kHz. TM motion displayed 1 peak at 1 kHz and 2 peaks at 3 kHz. Large amplitudes were detected in the posterosuperior quadrant (PSQ) at 1 kHz and in the PSQ and anteroinferior quadrant (AIQ) at 3 kHz. The entire TM showed synchronized movement centered on the PSQ at 1 kHz, with phase-shifting between PSQ and AIQ movement at 3 kHz. Amplitude was smaller at the umbo than at other parts. In contrast, amplitudes at high frequencies were too small and complicated to detect any obvious peaks. Sequential multipoint motion of the tympanic membrane showed that vibration characteristics of the TM differ according to the part and frequency.
High Spectral Resolution Lidar Measurements Using an I2 Absorption Filter
NASA Technical Reports Server (NTRS)
Eloranta, E. W.; Piironen, P.
1996-01-01
The University of Wisconsin high spectral resolution lidar (HSRL) measures optical properties of the atmosphere by separating the Doppler-broadened molecular backscatter return from the unbroadened aerosol return. The HSRL was modified to use an I2 absorption cell The modified HSRL transmitter uses a continuously pumped, Q-switched, injection seeded, frequency doubled Nd:YAG laser operating at a 4 kHz pulse repetition rate. This laser is tunable over a 124 GHz frequency range by temperature tuning the seed laser under computer control.
A cascaded Schwarz converter for high frequency power distribution
NASA Technical Reports Server (NTRS)
Ray, Biswajit; Stuart, Thomas A.
1988-01-01
It is shown that two Schwarz converters in cascade provide a very reliable 20-kHz source that features zero current commutation, constant frequency, and fault-tolerant operation, meeting requirements for spacecraft applications. A steady-state analysis of the converter is presented, and equations for the steady-state performance are derived. Fault-current limiting is discussed. Experimental results are presented for a 900-W version, which has been successfully tested under no-load, full-load, and short-circut conditions.
Echolocation in the Risso's dolphin, Grampus griseus
NASA Astrophysics Data System (ADS)
Philips, Jennifer D.; Nachtigall, Paul E.; Au, Whitlow W. L.; Pawloski, Jeffrey L.; Roitblat, Herbert L.
2003-01-01
The Risso's dolphin (Grampus griseus) is an exclusively cephalopod-consuming delphinid with a distinctive vertical indentation along its forehead. To investigate whether or not the species echolocates, a female Risso's dolphin was trained to discriminate an aluminum cylinder from a nylon sphere (experiment 1) or an aluminum sphere (experiment 2) while wearing eyecups and free swimming in an open-water pen in Kaneohe Bay, Hawaii. The dolphin completed the task with little difficulty despite being blindfolded. Clicks emitted by the dolphin were acquired at average amplitudes of 192.6 dB re 1 μPa, with estimated sources levels up to 216 dB re 1 μPa-1 m. Clicks were acquired with peak frequencies as high as 104.7 kHz (Mfp=47.9 kHz), center frequencies as high as 85.7 kHz (Mf0=56.5 kHz), 3-dB bandwidths up to 94.1 kHz (MBW=39.7 kHz), and root-mean-square bandwidths up to 32.8 kHz (MRMS=23.3 kHz). Click durations were between 40 and 70 μs. The data establish that the Risso's dolphin echolocates, and that, aside from slightly lower amplitudes and frequencies, the clicks emitted by the dolphin were similar to those emitted by other echolocating odontocetes. The particular acoustic and behavioral findings in the study are discussed with respect to the possible direction of the sonar transmission beam of the species.
Underwater detection of tonal signals between 0.125 and 100 kHz by harbor seals (Phoca vitulina).
Kastelein, Ronald A; Wensveen, Paul J; Hoek, Lean; Verboom, Willem C; Terhune, John M
2009-02-01
The underwater hearing sensitivities of two 1-year-old female harbor seals were quantified in a pool built for acoustic research, using a behavioral psychoacoustic technique. The animals were trained to respond when they detected an acoustic signal and not to respond when they did not (go/no-go response). Pure tones (0.125-0.25 kHz) and narrowband frequency modulated (tonal) signals (center frequencies 0.5-100 kHz) of 900 ms duration were tested. Thresholds at each frequency were measured using the up-down staircase method and defined as the stimulus level resulting in a 50% detection rate. The audiograms of the two seals did not differ statistically: both plots showed the typical mammalian U-shape, but with a wide and flat bottom. Maximum sensitivity (54 dB re 1 microPa, rms) occurred at 1 kHz. The frequency range of best hearing (within 10 dB of maximum sensitivity) was from 0.5 to 40 kHz (6(1/3) octaves). Higher hearing thresholds (indicating poorer sensitivity) were observed below 1 and above 40 kHz. Thresholds below 4 kHz were lower than those previously described for harbor seals, which demonstrates the importance of using quiet facilities, built specifically for acoustic research, for hearing studies in marine mammals. The results suggest that under unmasked conditions many anthropogenic noise sources and sounds from conspecifics are audible to harbor seals at greater ranges than formerly believed.
Song, Junho; Hynynen, Kullervo
2009-01-01
A hemispherical-focused, ultrasound phased array was designed and fabricated using 1372 cylindrical piezoelectric transducers that utilize lateral coupling for noninvasive transcranial therapy. The cylindrical transducers allowed the electrical impedance to be reduced by at least an order of magnitude, such that effective operation could be achieved without electronic matching circuits. In addition, the transducer elements generated the maximum acoustic average surface intensity of 27 W/cm2. The array, driven at the low (306 kHz) or high frequency (840 kHz), achieved excellent focusing through an ex vivo human skull and an adequate beam steering range for clinical brain treatments. It could electronically steer the ultrasound beam over cylindrical volumes of 100 mm in diameter and 60 mm in height at 306 kHz, and 30-mm in diameter and 30-mm in height at 840 kHz. A scanning laser vibrometer was used to investigate the radial and length mode vibrations of the element. The maximum pressure amplitudes through the skull at the geometric focus were predicted to be 5.5 MPa at 306 kHz and 3.7 MPa at 840 kHz for RF power of 1 W on each element. This is the first study demonstrating the feasibility of using cylindrical transducer elements and lateral coupling in construction of ultrasound phased arrays. PMID:19695987
Code of Federal Regulations, 2014 CFR
2014-10-01
.... Nominal carrier frequencies shall be integral multiples of 5 kHz. (2) Audio-frequency band. The upper limit of the audio-frequency band (at—3 dB) of the transmitter shall not exceed 4.5 kHz and the lower... processing. If audio-frequency signal processing is used, the dynamic range of the modulating signal shall be...
Code of Federal Regulations, 2012 CFR
2012-10-01
.... Nominal carrier frequencies shall be integral multiples of 5 kHz. (2) Audio-frequency band. The upper limit of the audio-frequency band (at—3 dB) of the transmitter shall not exceed 4.5 kHz and the lower... processing. If audio-frequency signal processing is used, the dynamic range of the modulating signal shall be...
Code of Federal Regulations, 2011 CFR
2011-10-01
.... Nominal carrier frequencies shall be integral multiples of 5 kHz. (2) Audio-frequency band. The upper limit of the audio-frequency band (at—3 dB) of the transmitter shall not exceed 4.5 kHz and the lower... processing. If audio-frequency signal processing is used, the dynamic range of the modulating signal shall be...
Code of Federal Regulations, 2013 CFR
2013-10-01
.... Nominal carrier frequencies shall be integral multiples of 5 kHz. (2) Audio-frequency band. The upper limit of the audio-frequency band (at—3 dB) of the transmitter shall not exceed 4.5 kHz and the lower... processing. If audio-frequency signal processing is used, the dynamic range of the modulating signal shall be...
NASA Astrophysics Data System (ADS)
Charaziak, Karolina K.; Siegel, Jonathan H.
2015-12-01
Otoacoustic emissions evoked with transient sounds (TEOAEs) are believed to originate within the tonotopic region of the stimulus in the cochlea via the same mechanisms as emissions evoked with single tones. However, we found that emissions evoked by low frequency (< 3 kHz) single-tones have an extended region of generation (> 6 mm) in chinchillas (Charaziak and Siegel, 2014, ARO Abst., 119). Here we test whether a broad region of generation for low-frequency stimuli is also a characteristic of TEOAEs evoked with 1-kHz tone pips extracted with compression and suppression methods. The TEOAE could be revealed with moderate level suppressors with frequencies extending beyond the stimulus bandwidth (up to 12.1 kHz), with the largest responses obtained with 3.1 - 4.1 kHz suppressors. There was a consistent decline in group delays of suppressor-revealed TEOAEs with increasing suppressor frequency, as expected if higher-frequency suppressors acted on more basal TEOAE generators. Effects of mid- to high-frequency acoustic trauma on TEOAE levels confirm the notion that the suppressors interact with emission components arising near the tonotopic place of the suppressor.
Acoustic signal recovery by thermal demodulation
NASA Astrophysics Data System (ADS)
Boullosa, R. R.; Santillán, Arturo O.
2006-10-01
One operating mode of recently developed thermoacoustic transducers is as an audio speaker that uses an input superimposed on a direct current; as a result, the audio signal occurs at the same frequency as the input signal. To extend the potential applications of these kinds of sources, the authors propose an alternative driving mode in which a simple thermoacoustic device, consisting of a metal film over a substrate and a heat sink, is excited with a high frequency sinusoid that is amplitude modulated by a lower frequency signal. They show that the modulating signal is recovered in the radiated waves due to a mechanism that is inherent to this type of thermoacoustic process. If the frequency of the carrier is higher than 30kHz and any modulating signal (the one of interest) is in the audio frequency range, only this signal will be heard. Thus, the thermoacoustic device operates as an audio-band, self-demodulating speaker.
Underwater localization of pure tones by harbor seals (Phoca vitulina).
Bodson, Anaïs; Miersch, Lars; Dehnhardt, Guido
2007-10-01
The underwater sound localization acuity of harbor seals (Phoca vitulina) was measured in the horizontal plane. Minimum audible angles (MAAs) of pure tones were determined as a function of frequency from 0.2 to 16 kHz for two seals. Testing was conducted in a 10-m-diam underwater half circle using a right/left psychophysical procedure. The results indicate that for both harbor seals, MAAs were large at high frequencies (13.5 degrees and 17.4 degrees at 16 kHz), transitional at intermediate frequencies (9.6 degrees and 10.1 degrees at 4 kHz), and particularly small at low frequencies (3.2 degrees and 3.1 degrees at 0.2 kHz). Harbor seals seem to be able to utilize both binaural cues, interaural time differences (ITDs) and interaural intensity differences (IIDs), but a significant decrease in the sound localization acuity with increasing frequency suggests that IID cues may not be as robust as ITD cues under water. These results suggest that the harbor seal can be regarded as a low-frequency specialist. Additionally, to obtain a MAA more representative of the species, the horizontal underwater MAA of six adult harbor seals was measured at 2 kHz under identical conditions. The MAAs of the six animals ranged from 8.8 degrees to 11.7 degrees , resulting in a mean MAA of 10.3 degrees .
Flexible and wearable 3D graphene sensor with 141 KHz frequency signal response capability
NASA Astrophysics Data System (ADS)
Xu, R.; Zhang, H.; Cai, Y.; Ruan, J.; Qu, K.; Liu, E.; Ni, X.; Lu, M.; Dong, X.
2017-09-01
We developed a flexible force sensor consisting of 3D graphene foam (GF) encapsulated in flexible polydimethylsiloxane (PDMS). Because the 3D GF/PDMS sensor is based on the transformation of an electronic band structure aroused by static mechanical strain or KHz vibration, it can detect frequency signals by both tuning fork tests and piezoelectric ceramic transducer tests, which showed a clear linear response from audio frequencies, including frequencies up to 141 KHz in the ultrasound range. Because of their excellent response with a wide bandwidth, the 3D GF/PDMS sensors are attractive for interactive wearable devices or artificial prosthetics capable of perceiving seismic waves, ultrasonic waves, shock waves, and transient pressures.
NASA Astrophysics Data System (ADS)
Sborikas, Martynas; Wegener, Michael
2013-12-01
Ferroelectrets are piezoelectric materials suitable for acoustic applications such as airborne ultrasonic transducers. Typical ferroelectrets exhibit resonance frequencies in the high kHz to low MHz range. In order to decrease the transducer resonance frequencies to the low kHz range, processes such as gas-diffusion expansion and electric charging were adjusted to cellular films which are initially twice as thick as in earlier studies. The demonstrated film expansion and electric charging lead to mechanically soft cellular structures which show high piezoelectric activities with coefficients up to 130 pC/N. Due to the simultaneously increased film thicknesses, the resonance frequencies are lowered down to about 233 kHz.
Temperature Dependence of Parametric Phenomenon in Airborne Ultrasound for Temperature Measurement
NASA Astrophysics Data System (ADS)
Kon, Akihiko; Wakatsuki, Naoto; Mizutani, Koichi
2008-08-01
The temperature dependence of parametric phenomenon in air was experimentally studied. It was confirmed from experimental data that the amplitude of upper sideband sound with a frequency of 36.175 kHz, which is caused by parametric phenomenon between high-power ultrasound with a frequency of 20.175 kHz and another normal sound with a frequency of 16.0 kHz, is proportional to -0.88×10-4×(T+273.15). This temperature dependence of the amplitude of upper sideband sound caused by the parametric phenomenon suggests a simple and effective method of temperature measurement.
Omega Navigation System Course Book. Volume 2
1994-07-01
STATION ID LOCATION LATITUDE LONGITUDE FREQUENCY RADIATED (kHz) POWER (kW) GBR§ Rugby , U.K. 52022’N 1011’W 16.0 45 JxZ§ Noviken, Norway 66058’N 13053’E...FREQUENCY RADIATEDIDENTIFICATION LOCATION (o)dg)kz)POWER(dog) (dog) (kHz) (kW) GBR Rugby , England 52.37N 1.19W 16.0 45 JXZ Noviken, Norway 66.97N 13.89E...IDENTIFICATION FREQUENCY RADIATED LOCATION LATITUDE LONGITUDE (kHz) POWER (kW) (deg) (deg) GBR 16.0 45 Rugby , England 52.37 N 1.19W JHZ 16.4 45 Noviken
Graphene earphones: entertainment for both humans and animals.
Tian, He; Li, Cheng; Mohammad, Mohammad Ali; Cui, Ya-Long; Mi, Wen-Tian; Yang, Yi; Xie, Dan; Ren, Tian-Ling
2014-06-24
The human hearing range is from 20 Hz to 20 kHz. However, many animals can hear much higher sound frequencies. Dolphins, especially, have a hearing range up to 300 kHz. To our knowledge, there is no data of a reported wide-band sound frequency earphone to satisfy both humans and animals. Here, we show that graphene earphones, packaged into commercial earphone casings can play sounds ranging from 100 Hz to 50 kHz. By using a one-step laser scribing technology, wafer-scale flexible graphene earphones can be obtained in 25 min. Compared with a normal commercial earphone, the graphene earphone has a wider frequency response (100 Hz to 50 kHz) and a three times lower fluctuation (±10 dB). A nonlinear effect exists in the graphene-generated sound frequency spectrum. This effect could be explained by the DC bias added to the input sine waves which may induce higher harmonics. Our numerical calculations show that the sound frequency emitted by graphene could reach up to 1 MHz. In addition, we have demonstrated that a dog wearing a graphene earphone could also be trained and controlled by 35 kHz sound waves. Our results show that graphene could be widely used to produce earphones for both humans and animals.
Baumann-Pickering, Simone; Wiggins, Sean M; Hildebrand, John A; Roch, Marie A; Schnitzler, Hans-Ulrich
2010-10-01
Spectral parameters were used to discriminate between echolocation clicks produced by three dolphin species at Palmyra Atoll: melon-headed whales (Peponocephala electra), bottlenose dolphins (Tursiops truncatus) and Gray's spinner dolphins (Stenella longirostris longirostris). Single species acoustic behavior during daytime observations was recorded with a towed hydrophone array sampling at 192 and 480 kHz. Additionally, an autonomous, bottom moored High-frequency Acoustic Recording Package (HARP) collected acoustic data with a sampling rate of 200 kHz. Melon-headed whale echolocation clicks had the lowest peak and center frequencies, spinner dolphins had the highest frequencies and bottlenose dolphins were nested in between these two species. Frequency differences were significant. Temporal parameters were not well suited for classification. Feature differences were enhanced by reducing variability within a set of single clicks by calculating mean spectra for groups of clicks. Median peak frequencies of averaged clicks (group size 50) of melon-headed whales ranged between 24.4 and 29.7 kHz, of bottlenose dolphins between 26.7 and 36.7 kHz, and of spinner dolphins between 33.8 and 36.0 kHz. Discriminant function analysis showed the ability to correctly discriminate between 93% of melon-headed whales, 75% of spinner dolphins and 54% of bottlenose dolphins.
Frank, T
2001-04-01
The first purpose of this study was to determine high-frequency (8 to 16 kHz) thresholds for standardizing reference equivalent threshold sound pressure levels (RETSPLs) for a Sennheiser HDA 200 earphone. The second and perhaps more important purpose of this study was to determine whether repeated high-frequency thresholds using a Sennheiser HDA 200 earphone had a lower intrasubject threshold variability than the ASHA 1994 significant threshold shift criteria for ototoxicity. High-frequency thresholds (8 to 16 kHz) were obtained for 100 (50 male, 50 female) normally hearing (0.25 to 8 kHz) young adults (mean age of 21.2 yr) in four separate test sessions using a Sennheiser HDA 200 earphone. The mean and median high-frequency thresholds were similar for each test session and increased as frequency increased. At each frequency, the high-frequency thresholds were not significantly (p > 0.05) different for gender, test ear, or test session. The median thresholds at each frequency were similar to the 1998 interim ISO RETSPLs; however, large standard deviations and wide threshold distributions indicated very high intersubject threshold variability, especially at 14 and 16 kHz. Threshold repeatability was determined by finding the threshold differences between each possible test session comparison (N = 6). About 98% of all of the threshold differences were within a clinically acceptable range of +/-10 dB from 8 to 14 kHz. The threshold differences between each subject's second, third, and fourth minus their first test session were also found to determine whether intrasubject threshold variability was less than the ASHA 1994 criteria for determining a significant threshold shift due to ototoxicity. The results indicated a false-positive rate of 0% for a threshold shift > or = 20 dB at any frequency and a false-positive rate of 2% for a threshold shift >10 dB at two consecutive frequencies. This study verified that the output of high-frequency audiometers at 0 dB HL using Sennheiser HDA 200 earphones should equal the 1998 interim ISO RETSPLs from 8 to 16 kHz. Further, because the differences between repeated thresholds were well within +/-10 dB and had an extremely low false-positive rate in reference to the ASHA 1994 criteria for a significant threshold shift due to ototoxicity, a Sennheiser HDA 200 earphone can be used for serial monitoring to determine whether significant high-frequency threshold shifts have occurred for patients receiving potentially ototoxic drug therapy.
47 CFR 80.882 - 2182 kHz watch.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false 2182 kHz watch. 80.882 Section 80.882 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... kHz watch. Ships subject to this subpart must maintain a watch on the frequency 2182 kHz pursuant to...
47 CFR 80.882 - 2182 kHz watch.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false 2182 kHz watch. 80.882 Section 80.882 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... kHz watch. Ships subject to this subpart must maintain a watch on the frequency 2182 kHz pursuant to...
47 CFR 80.882 - 2182 kHz watch.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false 2182 kHz watch. 80.882 Section 80.882 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... kHz watch. Ships subject to this subpart must maintain a watch on the frequency 2182 kHz pursuant to...
47 CFR 80.882 - 2182 kHz watch.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 5 2013-10-01 2013-10-01 false 2182 kHz watch. 80.882 Section 80.882 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... kHz watch. Ships subject to this subpart must maintain a watch on the frequency 2182 kHz pursuant to...
47 CFR 80.882 - 2182 kHz watch.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false 2182 kHz watch. 80.882 Section 80.882 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... kHz watch. Ships subject to this subpart must maintain a watch on the frequency 2182 kHz pursuant to...
47 CFR 87.133 - Frequency stability.
Code of Federal Regulations, 2014 CFR
2014-10-01
.... controlled airspace with 8.33 kHz channel spacing (except equipment being tested by avionics equipment... Tolerance 2 (1) Band-9 to 535 kHz: Aeronautical stations 100 100 Aircraft stations 200 100 Survival craft stations on 500 kHz 5,000 20 Hz 3 Radionavigation stations 100 100 (2) Band-1605 to 4000 kHz: Aeronautical...
NASA Technical Reports Server (NTRS)
Wilson, T. G.
1980-01-01
The development of 5 kW converters with 100 kHz switching frequencies, consisting of two submodules each capable of 2.5 kW of output power, is discussed. Two semiconductor advances allowed increased power levels. Field effect transistors with ratings of 11 A and 400 V were operated in parallel to provide a converter output power of approximately 2000 W. Secondly, bipolar power switching transistor was operated in conjunction with a turn-off snubber circuit to provide converter output power levels approaching 1000 W. The interrelationships between mass, switching frequency, and efficiency were investigated. Converters were constructed for operation at a maximum output power level of 200 W, and a comparison was made for operation under similar input/output conditions for conversion frequencies of 20 kilohertz and 100 kilohertz. The effects of nondissipative turn-off snubber circuitry were also examined. Finally, a computerized instrumentation system allowing the measurement of pertinent converter operating conditions as well as the recording of converter waveforms is described.
Electromagnetic radiation trapped in the magnetosphere above the plasma frequency
NASA Technical Reports Server (NTRS)
Gurnett, D. A.; Shaw, R. R.
1973-01-01
An electromagnetic noise band is frequently observed in the outer magnetosphere by the Imp 6 spacecraft at frequencies from about 5 to 20 kHz. This noise band generally extends throughout the region from near the plasmapause boundary to near the magnetopause boundary. The noise typically has a broadband field strength of about 5 microvolts/meter. The noise band often has a sharp lower cutoff frequency at about 5 to 10 kHz, and this cutoff has been identified as the local electron plasma frequency. Since the plasma frequency in the plasmasphere and solar wind is usually above 20 kHz, it is concluded that this noise must be trapped in the low-density region between the plasmapause and magnetopause boundaries. The noise bands often contain a harmonic frequency structure which suggests that the radiation is associated with harmonics of the electron cyclotron frequency.
NASA Astrophysics Data System (ADS)
Gaydecki, Patrick; Fernandes, Bosco
2003-11-01
A fast digital signal processing (DSP) system is described that can perform real-time emulation of a wide variety of linear audio-bandwidth systems and networks, such as reverberant spaces, musical instrument bodies and very high order filter networks. The hardware design is based upon a Motorola DSP56309 operating at 110 million multiplication-accumulations per second and a dual-channel 24 bit codec with a maximum sampling frequency of 192 kHz. High level software has been developed to express complex vector frequency responses as both infinite impulse response (IIR) and finite impulse response (FIR) coefficients, in a form suitable for real-time convolution by the firmware installed in the DSP system memory. An algorithm has also been devised to express IIR filters as equivalent FIR structures, thereby obviating the potential instabilities associated with recursive equations and negating the traditional deficiencies of FIR filters respecting equivalent analogue designs. The speed and dynamic range of the system is such that, when sampling at 48 kHz, the frequency response can be specified to a spectral precision of 22 Hz when sampling at 10 kHz, this resolution increases to 0.9 Hz. Moreover, it is also possible to control the phase of any frequency band with a theoretical precision of 10-5 degrees in all cases. The system has been applied in the study of analogue filter networks, real-time Hilbert transformation, phase-shift systems and musical instrument body emulation, where it is providing valuable new insights into the understanding of psychoacoustic mechanisms.
Liao, Jianqing; Qu, Baida; Liu, Da; Zheng, Naiqin
2015-11-01
A new method has been proposed for enhancing extraction yield of rutin from Sophora japonica, in which a novel ultrasonic extraction system has been developed to perform the determination of optimum ultrasonic frequency by a two-step procedure. This study has systematically investigated the influence of a continuous frequency range of 20-92 kHz on rutin yields. The effects of different operating conditions on rutin yields have also been studied in detail such as solvent concentration, solvent to solid ratio, ultrasound power, temperature and particle size. A higher extraction yield was obtained at the ultrasonic frequency of 60-62 kHz which was little affected under other extraction conditions. Comparative studies between existing methods and the present method were done to verify the effectiveness of this method. Results indicated that the new extraction method gave a higher extraction yield compared with existing ultrasound-assisted extraction (UAE) and soxhlet extraction (SE). Thus, the potential use of this method may be promising for extraction of natural materials on an industrial scale in the future. Copyright © 2015 Elsevier B.V. All rights reserved.
Jung, Minwan; Han Lee, Ju
2013-04-20
An actively Q-switched thulium-holmium-codoped fiber laser incorporating an Si-based variable optical attenuator (VOA) is experimentally demonstrated. It has been shown that an Si-based VOA with a response time of hundreds of nanoseconds can be used as a cost-effective 2 μm Q switch due to its extremely wide operating bandwidth from 1.5 to 2 μm, and low electrical power consumption. In our study, the laser's slope efficiency was measured to be ~17% at an operating wavelength of 1.89 μm. The repetition rate tuning range was from 20 to 80 kHz, which was limited by the optical damage threshold and the response time. The minimum temporal pulsewidth was measured to be ~184 ns at a modulation frequency of 20 kHz, and the corresponding maximum peak power was ~10 W.
Smith, D T; Pratt, J R; Howard, L P
2009-03-01
We have developed a fiber-optic interferometer optimized for best performance in the frequency range from dc to 1 kHz, with displacement linearity of 1% over a range of +/- 25 nm, and noise-limited resolution of 2 pm. The interferometer uses a tunable infrared laser source (nominal 1550 nm wavelength) with high amplitude and wavelength stability, low spontaneous self-emission noise, high sideband suppression, and a coherence control feature that broadens the laser linewidth and dramatically lowers the low-frequency noise in the system. The amplitude stability of the source, combined with the use of specially manufactured "bend-insensitive" fiber and all-spliced fiber construction, results in a robust homodyne interferometer system, which achieves resolution of 40 fm Hz(-1/2) above 20 Hz and approaches the shot-noise-limit of 20 fm Hz(-1/2) at 1 kHz for an optical power of 10 microW, without the need for differential detection. Here we describe the design and construction of the interferometer, as well as modes of operation, and demonstrate its performance.
Dependence of cavitation, chemical effect, and mechanical effect thresholds on ultrasonic frequency.
Thanh Nguyen, Tam; Asakura, Yoshiyuki; Koda, Shinobu; Yasuda, Keiji
2017-11-01
Cavitation, chemical effect, and mechanical effect thresholds were investigated in wide frequency ranges from 22 to 4880kHz. Each threshold was measured in terms of sound pressure at fundamental frequency. Broadband noise emitted from acoustic cavitation bubbles was detected by a hydrophone to determine the cavitation threshold. Potassium iodide oxidation caused by acoustic cavitation was used to quantify the chemical effect threshold. The ultrasonic erosion of aluminum foil was conducted to estimate the mechanical effect threshold. The cavitation, chemical effect, and mechanical effect thresholds increased with increasing frequency. The chemical effect threshold was close to the cavitation threshold for all frequencies. At low frequency below 98kHz, the mechanical effect threshold was nearly equal to the cavitation threshold. However, the mechanical effect threshold was greatly higher than the cavitation threshold at high frequency. In addition, the thresholds of the second harmonic and the first ultraharmonic signals were measured to detect bubble occurrence. The threshold of the second harmonic approximated to the cavitation threshold below 1000kHz. On the other hand, the threshold of the first ultraharmonic was higher than the cavitation threshold below 98kHz and near to the cavitation threshold at high frequency. Copyright © 2017 Elsevier B.V. All rights reserved.
Acoustically Tailored Composite Rotorcraft Fuselage Panels
NASA Technical Reports Server (NTRS)
Hambric, Stephen; Shepherd, Micah; Koudela, Kevin; Wess, Denis; Snider, Royce; May, Carl; Kendrick, Phil; Lee, Edward; Cai, Liang-Wu
2015-01-01
A rotorcraft roof sandwich panel has been redesigned to optimize sound power transmission loss (TL) and minimize structure-borne sound for frequencies between 1 and 4 kHz where gear meshing noise from the transmission has the most impact on speech intelligibility. The roof section, framed by a grid of ribs, was originally constructed of a single honeycomb core/composite face sheet panel. The original panel has coincidence frequencies near 700 Hz, leading to poor TL across the frequency range of 1 to 4 kHz. To quiet the panel, the cross section was split into two thinner sandwich subpanels separated by an air gap. The air gap was sized to target the fundamental mass-spring-mass resonance of the double panel system to less than 500 Hz. The panels were designed to withstand structural loading from normal rotorcraft operation, as well as 'man-on-the-roof' static loads experienced during maintenance operations. Thin layers of VHB 9469 viscoelastomer from 3M were also included in the face sheet ply layups, increasing panel damping loss factors from about 0.01 to 0.05. Measurements in the NASA SALT facility show the optimized panel provides 6-11 dB of acoustic transmission loss improvement, and 6-15 dB of structure-borne sound reduction at critical rotorcraft transmission tonal frequencies. Analytic panel TL theory simulates the measured performance quite well. Detailed finite element/boundary element modeling of the baseline panel simulates TL slightly more accurately, and also simulates structure-borne sound well.
47 CFR 76.610 - Operation in the frequency bands 108-137 and 225-400 MHz-scope of application.
Code of Federal Regulations, 2013 CFR
2013-10-01
... COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Technical... applicable to all MVPDs (cable and non-cable) transmitting carriers or other signal components carried at an average power level equal to or greater than 10−4 watts across a 25 kHz bandwidth in any 160 microsecond...
47 CFR 76.610 - Operation in the frequency bands 108-137 and 225-400 MHz-scope of application.
Code of Federal Regulations, 2010 CFR
2010-10-01
... COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Technical... applicable to all MVPDs (cable and non-cable) transmitting carriers or other signal components carried at an average power level equal to or greater than 10−4 watts across a 25 kHz bandwidth in any 160 microsecond...
47 CFR 76.610 - Operation in the frequency bands 108-137 and 225-400 MHz-scope of application.
Code of Federal Regulations, 2014 CFR
2014-10-01
... COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Technical... applicable to all MVPDs (cable and non-cable) transmitting carriers or other signal components carried at an average power level equal to or greater than 10−4 watts across a 25 kHz bandwidth in any 160 microsecond...
47 CFR 76.610 - Operation in the frequency bands 108-137 and 225-400 MHz-scope of application.
Code of Federal Regulations, 2012 CFR
2012-10-01
... COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Technical... applicable to all MVPDs (cable and non-cable) transmitting carriers or other signal components carried at an average power level equal to or greater than 10−4 watts across a 25 kHz bandwidth in any 160 microsecond...
47 CFR 27.53 - Emission limits.
Code of Federal Regulations, 2014 CFR
2014-10-01
... operations shall be limited to a maximum power flux density of −197 dBW/m2/4 kHz in the 2370-2390 MHz band at... displacement from the channel center frequency and measurement bandwidth. In the following tables, “(s... section of the printed volume and on GPO Access. Effective Date Note: At 79 FR 48539, Aug. 15, 2014, § 27...
Special Semaphore Scheme for UHF Spacecraft Communications
NASA Technical Reports Server (NTRS)
Butman, Stanley; Satorius, Edgar; Ilott, Peter
2006-01-01
A semaphore scheme has been devised to satisfy a requirement to enable ultrahigh- frequency (UHF) radio communication between a spacecraft descending from orbit to a landing on Mars and a spacecraft, in orbit about Mars, that relays communications between Earth and the lander spacecraft. There are also two subsidiary requirements: (1) to use UHF transceivers, built and qualified for operation aboard the spacecraft that operate with residual-carrier binary phase-shift-keying (BPSK) modulation at a selectable data rate of 8, 32, 128, or 256 kb/s; and (2) to enable low-rate signaling even when received signals become so weak as to prevent communication at the minimum BPSK rate of 8 kHz. The scheme involves exploitation of Manchester encoding, which is used in conjunction with residual-carrier modulation to aid the carrier-tracking loop. By choosing various sequences of 1s, 0s, or 1s alternating with 0s to be fed to the residual-carrier modulator, one would cause the modulator to generate sidebands at a fundamental frequency of 4 or 8 kHz and harmonics thereof. These sidebands would constitute the desired semaphores. In reception, the semaphores would be detected by a software demodulator.
Redondo, L M; Fernando Silva, J; Margato, E
2007-03-01
This article discusses the operation of a modular generator topology, which has been developed for high-frequency (kHz), high-voltage (kV) pulsed applications. The proposed generator uses individual modules, each one consisting of a pulse circuit based on a modified forward converter, which takes advantage of the required low duty cycle to operate with a low voltage clamp reset circuit for the step-up transformer. This reduces the maximum voltage on the semiconductor devices of both primary and secondary transformer sides. The secondary winding of each step-up transformer is series connected, delivering a fraction of the total voltage. Each individual pulsed module is supplied via an isolation transformer. The assembled modular laboratorial prototype, with three 5 kV modules, 800 V semiconductor switches, and 1:10 step-up transformers, has 80% efficiency, and is capable of delivering, into resistive loads, -15 kV1 A pulses with 5 micros width, 10 kHz repetition rate, with less than 1 micros pulse rise time. Experimental results for resistive loads are presented and discussed.
Outer heliospheric radio emissions. II - Foreshock source models
NASA Technical Reports Server (NTRS)
Cairns, Iver H.; Kurth, William S.; Gurnett, Donald A.
1992-01-01
Observations of LF radio emissions in the range 2-3 kHz by the Voyager spacecraft during the intervals 1983-1987 and 1989 to the present while at heliocentric distances greater than 11 AU are reported. New analyses of the wave data are presented, and the characteristics of the radiation are reviewed and discussed. Two classes of events are distinguished: transient events with varying starting frequencies that drift upward in frequency and a relatively continuous component that remains near 2 kHz. Evidence for multiple transient sources and for extension of the 2-kHz component above the 2.4-kHz interference signal is presented. The transient emissions are interpreted in terms of radiation generated at multiples of the plasma frequency when solar wind density enhancements enter one or more regions of a foreshock sunward of the inner heliospheric shock. Solar wind density enhancements by factors of 4-10 are observed. Propagation effects, the number of radiation sources, and the time variability, frequency drift, and varying starting frequencies of the transient events are discussed in terms of foreshock sources.
Echolocation in the Risso's dolphin, Grampus griseus.
Philips, Jennifer D; Nachtigall, Paul E; Au, Whitlow W L; Pawloski, Jeffrey L; Roitblat, Herbert L
2003-01-01
The Risso's dolphin (Grampus griseus) is an exclusively cephalopod-consuming delphinid with a distinctive vertical indentation along its forehead. To investigate whether or not the species echolocates, a female Risso's dolphin was trained to discriminate an aluminum cylinder from a nylon sphere (experiment 1) or an aluminum sphere (experiment 2) while wearing eyecups and free swimming in an open-water pen in Kaneohe Bay, Hawaii. The dolphin completed the task with little difficulty despite being blindfolded. Clicks emitted by the dolphin were acquired at average amplitudes of 192.6 dB re 1 microPa, with estimated sources levels up to 216 dB re 1 microPa-1 m. Clicks were acquired with peak frequencies as high as 104.7 kHz (Mf(p) = 47.9 kHz), center frequencies as high as 85.7 kHz (Mf(0) = 56.5 kHz), 3-dB bandwidths up to 94.1 kHz (M(BW) = 39.7 kHz), and root-mean-square bandwidths up to 32.8 kHz (M(RMS) = 23.3 kHz). Click durations were between 40 and 70 micros. The data establish that the Risso's dolphin echolocates, and that, aside from slightly lower amplitudes and frequencies, the clicks emitted by the dolphin were similar to those emitted by other echolocating odontocetes. The particular acoustic and behavioral findings in the study are discussed with respect to the possible direction of the sonar transmission beam of the species.
Ion plating with an induction heating source
NASA Technical Reports Server (NTRS)
Spalvins, T.; Brainard, W. A.
1976-01-01
Induction heating is introduced as an evaporation heat source in ion plating. A bare induction coil without shielding can be directly used in the glow discharge region with no arcing. The only requirement is to utilize an rf inductive generator with low operating frequency of 75 kHz. Mechanical simplicity of the ion plating apparatus and ease of operation is a great asset for industrial applications; practically any metal such as nickel, iron, and the high temperature refractories can be evaporated and ion plated.
Flexible, High-Speed CdSe Nanocrystal Integrated Circuits.
Stinner, F Scott; Lai, Yuming; Straus, Daniel B; Diroll, Benjamin T; Kim, David K; Murray, Christopher B; Kagan, Cherie R
2015-10-14
We report large-area, flexible, high-speed analog and digital colloidal CdSe nanocrystal integrated circuits operating at low voltages. Using photolithography and a newly developed process to fabricate vertical interconnect access holes, we scale down device dimensions, reducing parasitic capacitances and increasing the frequency of circuit operation, and scale up device fabrication over 4 in. flexible substrates. We demonstrate amplifiers with ∼7 kHz bandwidth, ring oscillators with <10 μs stage delays, and NAND and NOR logic gates.
Audiometric Characteristics of Hyperacusis Patients
Sheldrake, Jacqueline; Diehl, Peter U.; Schaette, Roland
2015-01-01
Hyperacusis is a frequent auditory disorder where sounds of normal volume are perceived as too loud or even painfully loud. There is a high degree of co-morbidity between hyperacusis and tinnitus, most hyperacusis patients also have tinnitus, but only about 30–40% of tinnitus patients also show symptoms of hyperacusis. In order to elucidate the mechanisms of hyperacusis, detailed measurements of loudness discomfort levels (LDLs) across the hearing range would be desirable. However, previous studies have only reported LDLs for a restricted frequency range, e.g., from 0.5 to 4 kHz or from 1 to 8 kHz. We have measured audiograms and LDLs in 381 patients with a primary complaint of hyperacusis for the full standard audiometric frequency range from 0.125 to 8 kHz. On average, patients had mild high-frequency hearing loss, but more than a third of the tested ears had normal hearing thresholds (HTs), i.e., ≤20 dB HL. LDLs were found to be significantly decreased compared to a normal-hearing reference group, with average values around 85 dB HL across the frequency range. However, receiver operating characteristic analysis showed that LDL measurements are neither sensitive nor specific enough to serve as a single test for hyperacusis. There was a moderate positive correlation between HTs and LDLs (r = 0.36), i.e., LDLs tended to be higher at frequencies where hearing loss was present, suggesting that hyperacusis is unlikely to be caused by HT increase, in contrast to tinnitus for which hearing loss is a main trigger. Moreover, our finding that LDLs are decreased across the full range of audiometric frequencies, regardless of the pattern or degree of hearing loss, indicates that hyperacusis might be due to a generalized increase in auditory gain. Tinnitus on the other hand is thought to be caused by neuroplastic changes in a restricted frequency range, suggesting that tinnitus and hyperacusis might not share a common mechanism. PMID:26029161
Effects of processing parameters in the sonic assisted water extraction (SAWE) of 6-gingerol.
Syed Jaapar, Syaripah Zaimah; Morad, Noor Azian; Iwai, Yoshio; Nordin, Mariam Firdhaus Mad
2017-09-01
The use of water in subcritical conditions for extraction has several drawbacks. These include the safety features, higher production costs and possible degradation of the bioactive compounds. To overcome these problems, sonic energy and an entrainer were used as external interventions to decrease the polarity of water at milder operating conditions. The effect of low (28kHz) and high (800kHz) frequencies of sonication in the extraction of the main ginger bioactive compound (6-gingerol) were compared. Six parameters were studied: mean particle size (MPS, mm), time of extraction, applied power, sample to solvent ratio (w/v), temperature of extraction, and the percentage of entrainer. The optimum conditions for high frequency SAWE prototype were MPS 0.89-1.77mm, 45min, 40W applied power, 1:30 (w/v), 45°C, and 15% of ethanol as entrainer. Two-way analysis of variance (ANOVA) gave the most significant parameter, which was power with F (1, 45.07), p<2.50×10 -9 . Although the effect of low frequency was stronger than high frequency, at the optimum conditions of the sample to solvent ratio 1:30 (w/v) with 700mL solvent and temperature 45°C, the concentration and recovery of 6-gingerol from high frequency of SAWE prototype was 2.69 times higher than at low frequency of SAWE. It was found that although the effects of high frequency (800kHz) were negligible in other studies, it could extract suitable compounds, such as 6-gingerol, at lower temperature. Therefore, the effects of sonication, which cause an enlargement in the cell wall of the ginger plant matrix, were observed using a Scanning Electron Microscope (SEM). It was found that the applied power of sonication was the most significant parameter compared to the other parameters. Copyright © 2017 Elsevier B.V. All rights reserved.
Nonlinear electromagnetic responses of active molecular motors in live cells and organelles
NASA Astrophysics Data System (ADS)
Nawarathna, Dharmakirthi; Gardner, Jeffrey; Cardenas, Gustavo; Warmflash, David; Miller, John; Widger, William; Claycomb, James
2006-03-01
The response of biological cells to an oscillatory electric field contains both linear and nonlinear (eg. induced harmonic) components. At low frequencies (about 10Hz), harmonic generation by budding yeast cells is observed. These induced harmonics are sensitive to sodium metavanadate, an inhibitor, and glucose, a substrate, respectively, of P-type ATPase membrane pumps. At higher frequencies, two peaks, around 3kHz and 12kHz, are observed in the frequency-dependent harmonic responses. These are sensitive to potassium cyanide, a respiratory inhibitor that blocks cytochrome c oxidase, an enzyme of the mitochondrial respiratory chain. We have also measured the response of uncoupled mitochondria extracted from bovine heart cells, for which a second harmonic sensitive to pericidin A and carboxin is detected at applied frequencies of 3-4kHz. Finally, in coupled mouse mitochondria, an ADP sensitive peak (12-15kHz) is observed, likely due to the F0 domain of ATP synthase, which acts as a molecular turbine.
Novel high-frequency energy-efficient pulsed-dc generator for capacitively coupled plasma discharge
NASA Astrophysics Data System (ADS)
Mamun, Md Abdullah Al; Furuta, Hiroshi; Hatta, Akimitsu
2018-03-01
The circuit design, assembly, and operating tests of a high-frequency and high-voltage (HV) pulsed dc generator (PDG) for capacitively coupled plasma (CCP) discharge inside a vacuum chamber are reported. For capacitive loads, it is challenging to obtain sharp rectangular pulses with fast rising and falling edges, requiring intense current for quick charging and discharging. The requirement of intense current generally limits the pulse operation frequency. In this study, we present a new type of PDG consisting of a pair of half-resonant converters and a constant current-controller circuit connected with HV solid-state power switches that can deliver almost rectangular high voltage pulses with fast rising and falling edges for CCP discharge. A prototype of the PDG is assembled to modulate from a high-voltage direct current (HVdc) input into a pulsed HVdc output, while following an input pulse signal and a set current level. The pulse rise time and fall time are less than 500 ns and 800 ns, respectively, and the minimum pulse width is 1 µs. The maximum voltage for a negative pulse is 1000 V, and the maximum repetition frequency is 500 kHz. During the pulse on time, the plasma discharge current is controlled steadily at the set value. The half-resonant converters in the PDG perform recovery of the remaining energy from the capacitive load at every termination of pulse discharge. The PDG performed with a high energy efficiency of 85% from the HVdc input to the pulsed dc output at a repetition rate of 1 kHz and with stable plasma operation in various discharge conditions. The results suggest that the developed PDG can be considered to be more efficient for plasma processing by CCP.
Novel high-frequency energy-efficient pulsed-dc generator for capacitively coupled plasma discharge.
Mamun, Md Abdullah Al; Furuta, Hiroshi; Hatta, Akimitsu
2018-03-01
The circuit design, assembly, and operating tests of a high-frequency and high-voltage (HV) pulsed dc generator (PDG) for capacitively coupled plasma (CCP) discharge inside a vacuum chamber are reported. For capacitive loads, it is challenging to obtain sharp rectangular pulses with fast rising and falling edges, requiring intense current for quick charging and discharging. The requirement of intense current generally limits the pulse operation frequency. In this study, we present a new type of PDG consisting of a pair of half-resonant converters and a constant current-controller circuit connected with HV solid-state power switches that can deliver almost rectangular high voltage pulses with fast rising and falling edges for CCP discharge. A prototype of the PDG is assembled to modulate from a high-voltage direct current (HVdc) input into a pulsed HVdc output, while following an input pulse signal and a set current level. The pulse rise time and fall time are less than 500 ns and 800 ns, respectively, and the minimum pulse width is 1 µs. The maximum voltage for a negative pulse is 1000 V, and the maximum repetition frequency is 500 kHz. During the pulse on time, the plasma discharge current is controlled steadily at the set value. The half-resonant converters in the PDG perform recovery of the remaining energy from the capacitive load at every termination of pulse discharge. The PDG performed with a high energy efficiency of 85% from the HVdc input to the pulsed dc output at a repetition rate of 1 kHz and with stable plasma operation in various discharge conditions. The results suggest that the developed PDG can be considered to be more efficient for plasma processing by CCP.
NASA Astrophysics Data System (ADS)
Konoplev, Oleg A.; Chiragh, Furqan L.; Vasilyev, Aleksey A.; Edwards, Ryan; Stephen, Mark A.; Troupaki, Elisavet; Yu, Anthony W.; Krainak, Michael A.; Sawruk, Nick; Hovis, Floyd; Culpepper, Charles F.; Strickler, Kathy
2016-05-01
We present the results of a three-year operational-aging test of a specially designed prototype flight laser operating at 1064 nm, 10 kHz, 1ns, 15W average power and externally frequency-doubled. Fibertek designed and built the q-switched, 1064nm laser and this laser was in a sealed container of dry air pressurized to 1.3 atm. The external frequency doubler was in a clean room at a normal air pressure. The goal of the experiment was to measure degradation modes at 1064 and 532 nm separately. The external frequency doubler consisted of a Lithium triborate, LiB3O5, non-critically phase-matched crystal. After some 1064 nm light was diverted for diagnostics, 13.7W of fundamental power was available to pump the doubling crystal. Between 8.5W and 10W of 532nm power was generated, depending on the level of stress and degradation. The test consisted of two stages, the first at 0.3 J/cm2 for almost 1 year, corresponding to expected operational conditions, and the second at 0.93 J/cm2 for the remainder of the experiment, corresponding to accelerated optical stress testing. We observed no degradation at the first stress-level and linear degradation at the second stress-level. The linear degradation was linked to doubler crystal output surface changes from laser-assisted contamination. We estimate the expected lifetime for the flight laser at 532 nm using fluence as the stress parameter. This work was done for NASA's Ice, Cloud, and land Elevation Satellite-2 (ICESat-2) LIDAR at Goddard Space Flight Center in Greenbelt, MD with the goal of 1 trillion shots lifetime.
Characterization of the MEMS Directional Sound Sensor in the High Frequency (15-20 kHz) Range
2011-12-01
frequency response that is almost flat from 50 Hz to 20 kHz [9]. The sound source is a Selenium loudspeaker type DH200E attached to the internal...University Science Books, 2005. [12] W. Zhang and K. Turner, “Frequency dependent fluid damping of micro/ nano flexural resonators: Experiment, model and
Kastelein, Ronald A; Hoek, Lean; de Jong, Christ A F; Wensveen, Paul J
2010-11-01
The underwater hearing sensitivity of a young male harbor porpoise for tonal signals of various signal durations was quantified by using a behavioral psychophysical technique. The animal was trained to respond only when it detected an acoustic signal. Fifty percent detection thresholds were obtained for tonal signals (15 frequencies between 0.25-160 kHz, durations 0.5-5000 ms depending on the frequency; 134 frequency-duration combinations in total). Detection thresholds were quantified by varying signal amplitude by the 1-up 1-down staircase method. The hearing thresholds increased when the signal duration fell below the time constant of integration. The time constants, derived from an exponential model of integration [Plomp and Bouman, J. Acoust. Soc. Am. 31, 749-758 (1959)], varied from 629 ms at 2 kHz to 39 ms at 64 kHz. The integration times of the porpoises were similar to those of other mammals including humans, even though the porpoise is a marine mammal and a hearing specialist. The results enable more accurate estimations of the distances at which porpoises can detect short-duration environmental tonal signals. The audiogram thresholds presented by Kastelein et al. [J. Acoust. Soc. Am. 112, 334-344 (2002)], after correction for the frequency bandwidth of the FM signals, are similar to the results of the present study for signals of 1500 ms duration. Harbor porpoise hearing is more sensitive between 2 and 10 kHz, and less sensitive above 10 kHz, than formerly believed.
NASA Astrophysics Data System (ADS)
Yamaguchi, Tomoyo; Sakamoto, Naoshi; Shimozuma, Mitsuo; Yoshino, Masaki; Tagashira, Hiroaki
1998-01-01
Dust particle formation dynamics in the process of SiOx film deposition from a SiH4 and N2O gas mixture by a low frequency plasma enhanced chemical vapor deposition have been investigated using scanning electron microscopy and laser light scattering. The deposited films are confirmed to be SiOx from the measurements of Auger electron spectroscopy, x-ray photoelectron spectroscopy, and Fourier transform infrared spectroscopy. It is observed by scanning electron microscopy that particles are deposited on Si substrate at the plasma power frequency f=5 kHz and above both with and without substrate heating (400 °C), while no particle is deposited below f=1 kHz. Moreover, the laser light scattering indicates that particles are generated at the plasma power frequency of f=3 kHz and above in the gas phase, and that they are not generated in the gas phase at below f=3 kHz. Properties (the refractive index, resistivity, and Vickers hardness) of the films with particles are inferior to those of the films without particles. This article has revealed experimentally the effect of plasma power frequency on SiOx particle formation and makes a contribution to the explication of the particle formation mechanism. We suggest that high-quality film deposition with the low frequency plasma enhanced chemical vapor deposition method is attained at f=1 kHz or less without substrate heating.
Variable speed induction motor operation from a 20-kHz power bus
NASA Technical Reports Server (NTRS)
Hansen, Irving G.
1989-01-01
Induction motors are recognized for their simple rugged construction to date, however, their application to variable speed or servo drives has been hampered by limitations on their control. Induction motor drives tend to be complex and to display troublesome low speed characteristics due in part to nonsinusoidal driving voltages. A technique was developed which involves direct synthesis of sinusoidal driving voltages from a high frequency power bus and independent control of frequency and voltages. Separation offrequency and voltage allows independent control of rotor and stator flux, full four-quadrant operation, and instantaneous torque control. Recent test results, current status of the technology, and proposed aerospace applications will be discussed.
NASA Astrophysics Data System (ADS)
Ramachandran, Hema; Pillai, K. P. P.; Bindu, G. R.
2017-08-01
A two-port network model for a wireless power transfer system taking into account the distributed capacitances using PP network topology with top coupling is developed in this work. The operating and maximum power transfer efficiencies are determined analytically in terms of S-parameters. The system performance predicted by the model is verified with an experiment consisting of a high power home light load of 230 V, 100 W and is tested for two forced resonant frequencies namely, 600 kHz and 1.2 MHz. The experimental results are in close agreement with the proposed model.
Lightweight, high-frequency transformers
NASA Technical Reports Server (NTRS)
Schwarze, G. E.
1983-01-01
The 25-kVA space transformer was developed under contract by Thermal Technology Laboratory, Buffalo, N. Y. The NASA Lewis transformer technology program attempted to develop the baseline technology. For the 25-kVA transformer the input voltage was chosen as 200 V, the output voltage as 1500 V, the input voltage waveform as square wave, the duty cycle as continuous, the frequency range (within certain constraints) as 10 to 40 kHz, the operating temperatures as 85 deg. and 130 C, the baseplate temperature as 50 C, the equivalent leakage inductance as less than 10 micro-h, the operating environment as space, and the life expectancy as 10 years. Such a transformer can also be used for aircraft, ship and terrestrial applications.
Development of rotating magnetic field coil system in the HIST spherical torus device
NASA Astrophysics Data System (ADS)
Yoshikawa, T.; Kikuchi, Y.; Yamada, S.; Hashimoto, S.; Nishioka, T.; Fukumoto, N.; Nagata, M.
2007-11-01
Coaxial Helicity Injection (CHI) is one of most attractive methods to achieve non-inductive current drive in spherical torus devices. The current drive mechanism of CHI relies on MHD relaxation process of rotating kink behavior [1], so that there is a possibility to control the CHI by using an externally applied rotating magnetic field (RMF). We have recently started to develop a RMF coil system in the HIST spherical torus device. Eight coils are located above and below the midplane at four toroidal locations so that the RMF is resonant with n = 1 rotating kink mode driven by the CHI. In addition, the RMF coil set is installed inside a flux conserver of 5 mm thickness (cut-off frequency ˜ 170 Hz) so that the RMF penetrates into the plasma. The coil winding is made of 20 turns of enameled copper circular wires (1.5 mm^2 conductor cross section), covered with a thin stainless steal case of 0.5 mm thickness (cut-off frequency ˜ 710 kHz). The RMF system is driven by an IGBT inverter power supply (nominal current: 1 kA, nominal voltage: 1 kV) with an operating frequency band from 10 kHz to 30 kHz. The estimated amplitude of RMF neglecting effects of image current at the flux conserver is a few tens Gauss at around the magnetic axis. A preliminary experimental result will be shown in the conference. [1] M. Nagata, et al., Physics of Plasmas 10, 2932 (2003).
Digital Low Level RF Systems for Fermilab Main Ring and Tevatron
NASA Astrophysics Data System (ADS)
Chase, B.; Barnes, B.; Meisner, K.
1997-05-01
At Fermilab, a new Low Level RF system is successfully installed and operating in the Main Ring. Installation is proceeding for a Tevatron system. This upgrade replaces aging CAMAC/NIM components for an increase in accuracy, reliability, and flexibility. These VXI systems are based on a custom three channel direct digital synthesizer(DDS) module. Each synthesizer channel is capable of independent or ganged operation for both frequency and phase modulation. New frequency and phase values are computed at a 100kHz rate on the module's Analog Devices ADSP21062 (SHARC) digital signal processor. The DSP concurrently handles feedforward, feedback, and beam manipulations. Higher level state machines and the control system interface are handled at the crate level using the VxWorks operating system. This paper discusses the hardware, software and operational aspects of these LLRF systems.
Kastelein, Ronald A; Hoek, Lean; Wensveen, Paul J; Terhune, John M; de Jong, Christ A F
2010-02-01
The underwater hearing sensitivities of two 2-year-old female harbor seals were quantified in a pool built for acoustic research by using a behavioral psycho-acoustic technique. The animals were trained only to respond when they detected an acoustic signal ("go/no-go" response). Detection thresholds were obtained for pure tone signals (frequencies: 0.2-40 kHz; durations: 0.5-5000 ms, depending on the frequency; 59 frequency-duration combinations). Detection thresholds were quantified by varying the signal amplitude by the 1-up, 1-down staircase method, and were defined as the stimulus levels, resulting in a 50% detection rate. The hearing thresholds of the two seals were similar for all frequencies except for 40 kHz, for which the thresholds differed by, on average, 3.7 dB. There was an inverse relationship between the time constant (tau), derived from an exponential model of temporal integration, and the frequency [log(tau)=2.86-0.94 log(f);tau in ms and f in kHz]. Similarly, the thresholds increased when the pulse was shorter than approximately 780 cycles (independent of the frequency). For pulses shorter than the integration time, the thresholds increased by 9-16 dB per decade reduction in the duration or number of cycles in the pulse. The results of this study suggest that most published hearing thresholds
Stroke dynamics and frequency of 3 phacoemulsification machines.
Tognetto, Daniele; Cecchini, Paolo; Leon, Pia; Di Nicola, Marta; Ravalico, Giuseppe
2012-02-01
To measure the working frequency and the stroke dynamics of the phaco tip of 3 phacoemulsification machines. University Eye Clinic of Trieste, Italy. Experimental study. A video wet fixture was assembled to measure the working frequency using a micro camera and a micropulsed strobe-light system. A different video wet fixture was created to measure tip displacement as vectorial movement at different phaco powers using a microscopic video apparatus. The working frequency of the Infiniti Ozil machine was 43.0 kHz in longitudinal mode and 31.6 kHz in torsional mode. The frequency of the Whitestar Signature machine was 29.0 kHz in longitudinal mode and 38.0 kHz with the Ellips FX handpiece. The Stellaris machine had a frequency of 28.8 kHz. The longitudinal stroke of the 3 machines at different phaco powers was statistically significantly different. The Stellaris machine had the highest stroke extent (139 μm). The lateral movement of the Infiniti Ozil and Whitestar Signature machines differed significantly. No movement on the y-axis was observed for the Infiniti Ozil machine in torsional mode. The elliptical path of the Ellips FX handpiece had different x and y components at different phaco powers. The 3 phaco machines performed differently in terms of working frequency and stroke dynamics. The knowledge of the peculiar lateral and elliptical path strokes of Infiniti and Whitestar Signature machines may allow the surgeon to fully use these features for lens removal. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Hedlund, Brock E.; Houpt, Alec W.; Gordeyev, Stanislav V.; Leonov, Sergey B.
2017-10-01
This study was performed to characterize the dominant frequencies present in the boundary layer uptsream of and in the corner separation zone of a compression surface in Mach 4.5 flow and to determine a control effect of transient plasma actuation on the boundary layer. Schlieren imaging was used to distinguish the corner separation zone for 20°, 25°, and 30° compression ramps mounted on flat plates. Spectra of the natural disturbances present in the boundary layer and separation zone were gathered using a high-speed Shack-Hartmann wavefront sensor and surface mounted PCBTM pressure sensors while varying flow parameters by adjusting total pressure, temperature, and ramp angle. Shallow cavity discharge plasma actuators were used as a high-frequency localized thermal forcing mechanism of the boundary layer. The plasma effect was negligible for forcing frequencies (50 kHz) below the natural dominant frequency (~55-80 kHz). High frequency perturbations that can promote the transition to turbulence were amplified when the plasma forcing frequency (100 kHz) was higher than the natural dominant frequency (~55-80 kHz). This technique can potentially be used for active control of hypersonic boundary layer transition and the supersonic flow structure on the compression surface.
Initial Thrust Measurements of Marshall's Ion-ioN Thruster
NASA Technical Reports Server (NTRS)
Caruso, Natalie R. S.; Scogin, Tyler; Liu, Thomas M.; Walker, Mitchell L. R.; Polzin, Kurt A.; Dankanich, John W.
2015-01-01
Electronegative ion thrusters are a variation of traditional gridded ion thruster technology differentiated by the production and acceleration of both positive and negative ions. Benefits of electronegative ion thrusters include the elimination of lifetime-limiting cathodes from the thruster architecture and the ability to generate appreciable thrust from both charge species. While much progress has been made in the development of electronegative ion thruster technology, direct thrust measurements are required to unambiguously demonstrate the efficacy of the concept and support continued development. In the present work, direct thrust measurements of the thrust produced by the MINT (Marshall's Ion-ioN Thruster) are performed using an inverted-pendulum thrust stand in the High-Power Electric Propulsion Laboratory's Vacuum Test Facility-1 at the Georgia Institute of Technology with operating pressures ranging from 4.8 x 10(exp -5) and 5.7 x 10(exp -5) torr. Thrust is recorded while operating with a propellant volumetric mixture ratio of 5:1 argon to nitrogen with total volumetric flow rates of 6, 12, and 24 sccm (0.17, 0.34, and 0.68 mg/s). Plasma is generated using a helical antenna at 13.56 MHz and radio frequency (RF) power levels of 150 and 350 W. The acceleration grid assembly is operated using both sinusoidal and square waveform biases of +/-350 V at frequencies of 4, 10, 25, 125, and 225 kHz. Thrust is recorded for two separate thruster configurations: with and without the magnetic filter. No thrust is discernable during thruster operation without the magnetic filter for any volumetric flow rate, RF forward Power level, or acceleration grid biasing scheme. For the full thruster configuration, with the magnetic filter installed, a brief burst of thrust of approximately 3.75 mN +/- 3 mN of error is observed at the start of grid operation for a volumetric flow rate of 24 sccm at 350 W RF power using a sinusoidal waveform grid bias at 125 kHz and +/- 350 V. Similar bursts in thrust are observed using a square waveform grid bias at 10 kHz and +/- 350 V for volumetric flow rates of 6, 10, and 12 sccm at 150, 350, and 350 W respectively. The only operating condition that exhibits repeated thrust spikes throughout thruster operation is the 24 sccm condition with a 5:1 mixture ratio at 150 W RF power using the 10 kHz square waveform acceleration grid bias. Thrust spikes for this condition measure 3 mN with an error of +/- 2.5 mN. There are no operating conditions tested that show continuous thrust production.
NASA Astrophysics Data System (ADS)
Wang, Xingxing; Shashurin, Alexey
2017-02-01
This paper presents and studies helium atmospheric pressure plasma jet comprised of a series of repetitive streamer breakdowns, which is driven by pure DC high voltage (self-oscillatory behavior). The repetition frequency of the breakdowns is governed by the geometry of discharge electrodes/surroundings and gas flow rate. Each next streamer is initiated when the electric field on the anode tip recovers after the previous breakdown and reaches the breakdown threshold value of about 2.5 kV cm-1. One type of the helium plasma gun designed using this operational principle is demonstrated. The gun operates on about 3 kV DC high voltage and is comprised of the series of the repetitive streamer breakdowns at a frequency of about 13 kHz.
Atomic Oxygen Energy in Low Frequency Hyperthermal Plasma Ashers
NASA Technical Reports Server (NTRS)
Banks, Bruce A.; Miller, Sharon K R.; Kneubel, Christian A.
2014-01-01
Experimental and analytical analysis of the atomic oxygen erosion of pyrolytic graphite as well as Monte Carlo computational modeling of the erosion of Kapton H (DuPont, Wilmington, DE) polyimide was performed to determine the hyperthermal energy of low frequency (30 to 35 kHz) plasma ashers operating on air. It was concluded that hyperthermal energies in the range of 0.3 to 0.9 eV are produced in the low frequency air plasmas which results in texturing similar to that in low Earth orbit (LEO). Monte Carlo computational modeling also indicated that such low energy directed ions are fully capable of producing the experimentally observed textured surfaces in low frequency plasmas.
Plasma antennas driven by 5–20 kHz AC power supply
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Jiansen, E-mail: 67093058@qq.com; Chen, Yuli; Sun, Yang
2015-12-15
The experiments described in this work were performed with the aim of introducing a new plasma antenna that was excited by a 5–20 kHz alternating current (AC) power supply, where the antenna was transformed into a U-shape. The results show that the impedance, voltage standing-wave ratio (VSWR), radiation pattern and gain characteristics of the antenna can be controlled rapidly by varying not only the discharge power, but also by varying the discharge frequency in the range from 5 to 20 kHz. When the discharge frequency is adjusted from 10 to 12 kHz, the gain is higher within a relatively broadmore » frequency band and the switch-on time is less than 1 ms when the discharge power is less than 5 W, meaning that the plasma antenna can be turned on and off rapidly.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-13
...]Pa rms. Due to its high frequency range, NMFS does not consider its acoustic energy would be strong... source levels of the sub-bottom profiler and the high-frequency nature of the multi-beam echo sounder...-frequency side scan sonar, (100-400 kHz or 300-600 kHz): Based on Shell's 2006 90-day report, the source...
47 CFR 80.373 - Private communications frequencies.
Code of Federal Regulations, 2010 CFR
2010-10-01
... band for medical advisory communications. (1) Private coast stations may be authorized to use any... stations of radiotelephony frequencies in the 2000-27500 kHz band are subject to the following: (1) Private... stations serving lakes or rivers are not authorized on the 2000-2850 kHz band. (4) Private coast stations...
Metrology of vibration measurements by laser techniques
NASA Astrophysics Data System (ADS)
von Martens, Hans-Jürgen
2008-06-01
Metrology as the art of careful measurement has been understood as uniform methodology for measurements in natural sciences, covering methods for the consistent assessment of experimental data and a corpus of rules regulating application in technology and in trade and industry. The knowledge, methods and tools available for precision measurements can be exploited for measurements at any level of uncertainty in any field of science and technology. A metrological approach to the preparation, execution and evaluation (including expression of uncertainty) of measurements of translational and rotational motion quantities using laser interferometer methods and techniques will be presented. The realization and dissemination of the SI units of motion quantities (vibration and shock) have been based on laser interferometer methods specified in international documentary standards. New and upgraded ISO standards are reviewed with respect to their suitability for ensuring traceable vibration measurements and calibrations in an extended frequency range of 0.4 Hz to higher than 100 kHz. Using adequate vibration exciters to generate sufficient displacement or velocity amplitudes, the upper frequency limits of the laser interferometer methods specified in ISO 16063-11 for frequencies <= 10 kHz can be expanded to 100 kHz and beyond. A comparison of different methods simultaneously used for vibration measurements at 100 kHz will be demonstrated. A statistical analysis of numerous experimental results proves the highest accuracy achievable currently in vibration measurements by specific laser methods, techniques and procedures (i.e. measurement uncertainty 0.05 % at frequencies <= 10 kHz, <= 1 % up to 100 kHz).
Sunny, Youhan; Bawiec, Christopher R; Nguyen, An T; Samuels, Joshua A; Weingarten, Michael S; Zubkov, Leonid A; Lewin, Peter A
2012-09-01
This paper describes optimization of un-tethered, low voltage, 20-100kHz flexural transducers for biomedical ultrasonics applications. The goal of this work was to design a fully wearable, low weight (<100g), battery operated, piezoelectric ultrasound applicator providing maximum output pressure amplitude at the minimum excitation voltage. Such implementation of ultrasound applicators that can operate at the excitation voltages on the order of only 10-25V is needed in view of the emerging evidence that spatial-peak temporal-peak ultrasound intensity (I(SPTP)) on the order of 100mW/cm(2) delivered at frequencies below 100kHz can have beneficial therapeutic effects. The beneficial therapeutic applications include wound management of chronic ulcers and non-invasive transdermal delivery of insulin and liposome encapsulated drugs. The early prototypes of the 20 and 100kHz applicators were optimized using the maximum electrical power transfer theorem, which required a punctilious analysis of the complex impedance of the piezoelectric disks mounted in appropriately shaped metal housings. In the implementation tested, the optimized ultrasound transducer applicators were driven by portable, customized electronics, which controlled the excitation voltage amplitude and facilitated operation in continuous wave (CW) or pulsed mode with adjustable (10-90%) duty cycle. The driver unit was powered by remotely located rechargeable lithium (Li) polymer batteries. This was done to further minimize the weight of the applicator unit making it wearable. With DC voltage of approximately 15V the prototypes were capable of delivering pressure amplitudes of about 55kPa or 100mW/cm(2) (I(SPTP)). This level of acoustic output was chosen as it is considered safe and side effects free, even at prolonged exposure. Copyright © 2012. Published by Elsevier B.V.
Interface circuit for a multiple-beam tuning-fork gyroscope with high quality factors
NASA Astrophysics Data System (ADS)
Wang, Ren
This research work presents the design, theoretical analysis, fabrication, interface electronics, and experimental results of a Silicon-On-Insulator (SOI) based Multiple-Beam Tuning-Fork Gyroscope (MB-TFG). Based on a numerical model of Thermo-Elastic Damping (TED), a Multiple-Beam Tuning-Fork Structure (MB-TFS) is designed with high Quality factors (Qs) in its two operation modes. A comprehensive theoretical analysis of the MB-TFG design is conducted to relate the design parameters to its operation parameters and further performance parameters. In conjunction with a mask that defines the device through trenches to alleviate severe fabrication effect on anchor loss, a simple one-mask fabrication process is employed to implement this MB-TFG design on SOI wafers. The fabricated MB-TFGs are tested with PCB-level interface electronics and a thorough comparison between the experimental results and a theoretical analysis is conducted to verify the MB-TFG design and accurately interpret the measured performance. The highest measured Qs of the fabricated MB-TFGs in vacuum are 255,000 in the drive-mode and 103,000 in the sense-mode, at a frequency of 15.7kHz. Under a frequency difference of 4Hz between the two modes (operation frequency is 16.8kHz) and a drive-mode vibration amplitude of 3.0um, the measured rate sensitivity is 80mVpp/°/s with an equivalent impedance of 6MQ. The calculated overall rate resolution of this device is 0.37/hrhiElz, while the measured Angle Random Walk (ARW) and bias instability are 6.67°/'vhr and 95°/hr, respectively.
Development of ultrasound focusing discrete array for air-coupled ultrasound generation
NASA Astrophysics Data System (ADS)
Korobov, Alexander I.; Izosimova, Maria Y.; Toschov, Sergey A.
2010-01-01
The technique and results of synthesis of ultrasound focusing discrete arrays for air-coupled ultrasound generation are presented. One of the arrays is an antenna 22 cm in diameter. It consists of 60 transmitters of Murata Company. The resonant frequency of each transmitter is 40 kHz, diameter is 16 mm. The transmitters were placed in first four Fresnel zones. Each of the zones was emitting with anti-phases. Position data and pressure field in focus were calculated using Rayleigh integral. Parameters of made array were measured using method of air-coupled vibrometry with laser scanning vibrometer. Measured parameters (operating frequency is 40 ± 1 kHz, focal distance is 308 mm, size of focal spot is 16.3 mm, and pressure in focus is about 150 dB) are in good agreement with calculated data. The examples of use of designed arrays for noncontact non-destructive diagnostics of some structural materials are reported. Work supported by RFBR.
Multiphase power supply when inverting currents for group of Peltier elements
NASA Astrophysics Data System (ADS)
Osintsev, A. V.; Sobko, A. A.; Komnatnov, M. E.
2018-05-01
The use of multiphase power supply of a group of Peltier elements (PE) is considered to reduce the load on the power source. Schemes and a control layout with the use of the H-bridge, allowing the invert of the current through the PE, are given. The analysis of the operation of the used H-bridges and PE in the frequency range of the control PWM signal from 30 Hz to 32 kHz is performed. The algorithm for monitoring the current sensors is presented and the time diagrams of the currents are represented through the PE and H-bridges using a two-phase and four-phase control PWM signal for one, two and four phases of the supply. The results showed stable heating and cooling of the PE at frequencies from 30 Hz to 1 kHz. The use of multiphase power supply of PE made it possible to significantly reduce the load on the power source.
NASA Astrophysics Data System (ADS)
Boxx, I.; Stöhr, M.; Carter, C.; Meier, W.
2009-04-01
We describe an approach of imaging the dynamic interaction of the flamefront and flowfield. Here, a diode-pumped Nd:YLF laser operating at 5 kHz is used to pump a dye laser, which is then frequency doubled to 283 nm to probe flamefront OH, while a dual cavity diode-pumped Nd:YAG system produces pulse-pairs for particle image velocimetry (PIV). CMOS digital cameras are used to detect both planar laser-induced fluorescence (PLIF) and particle scattering (in a stereo arrangement) such that a 5 kHz measurement frequency is attained. This diagnostic is demonstrated in lifted-jet and swirl-stabilized flames, wherein the dynamics of the flame stabilization processes are seen. Nonperiodic effects such as local ignition and/or extinction, lift-off and flashback events, and their histories can be captured by this technique. As such, this system has the potential to significantly extend our understanding of nonstationary combustion processes relevant to industrial and technical applications.
LD-pumped actively Q-switched c-cut Nd:GdVO4 self-Raman laser operating at 1166 and 1176 nm
NASA Astrophysics Data System (ADS)
Sun, Xinzhi; Zhang, Xihe; Li, Shutao; Dong, Yuan
2017-12-01
A laser diode pumped actively Q-switched c-cut Nd:GdVO4 self-Raman laser is experimentally investigated. Simultaneous pulse outputs at 1166 nm and 1176 nm corresponding to the Raman shifts of 807 and 882 cm-1 are acquired. At the pulse repetition frequency (PRF) of 20 kHz, the maximum output power is 103 mW at 1166 nm with the incident pump power of 2.31 W, while 1176 nm output power reaches 530 mW with the incident pump power of 4.11 W. The maximum output power of Raman laser is 570 mW with the incident pump power of 4.11 W and the PRF of 30 kHz. With the incident pump power of 3.67 W and the PRF of 30 kHz, the highest diode-to-Stokes optical conversion efficiency of 14.9% is obtained with the corresponding average output power of 547 mW.
Al-Hamadani, Yasir A J; Chu, Kyoung Hoon; Flora, Joseph R V; Kim, Do-Hyung; Jang, Min; Sohn, Jinsik; Joo, Wanho; Yoon, Yeomin
2016-09-01
Sonocatalytic degradation experiments were carried out to determine the effects of glass beads (GBs) and single-walled carbon nanotubes (SWNTs) on ibuprofen (IBP) and sulfamethoxazole (SMX) removal using low and high ultrasonic frequencies (28 and 1000kHz). In the absence of catalysts, the sonochemical degradation at pH 7, optimum power of 0.18WmL(-1), and a temperature of 15°C was higher (79% and 72%) at 1000kHz than at 28kHz (45% and 33%) for IBP and SMX, respectively. At the low frequency (28kHz) H2O2 production increased significantly, from 10μM (no GBs) to 86μM in the presence of GBs (0.1mm, 10gL(-1)); however, no enhancement was achieved at 1000kHz. In contrast, the H2O2 production increased from 10μM (no SWNTs) to 31μM at 28kHz and from 82μM (no SWNTs) to 111μM at 1000kHz in the presence of SWNTs (45mgL(-1)). Thus, maximum removals of IBP and SMX were obtained in the presence of a combination of GBs and SWNTs at the low frequency (94% and 88%) for 60min contact time; however, >99% and 97% removals were achieved for 40 and 60min contact times at the high frequency for IBP and SMX, respectively. The results indicate that both IBP and SMX degradation followed pseudo-first-order kinetics. Additionally, the enhanced removal of IBP and SMX in the presence of catalysts was because GBs and SWNTs increased the number of free OH radicals due to ultrasonic irradiation and the adsorption capacity increase with SWNT dispersion. Copyright © 2016 Elsevier B.V. All rights reserved.
Transparent megahertz circuits from solution-processed composite thin films.
Liu, Xingqiang; Wan, Da; Wu, Yun; Xiao, Xiangheng; Guo, Shishang; Jiang, Changzhong; Li, Jinchai; Chen, Tangsheng; Duan, Xiangfeng; Fan, Zhiyong; Liao, Lei
2016-04-21
Solution-processed amorphous oxide semiconductors have attracted considerable interest in large-area transparent electronics. However, due to its relative low carrier mobility (∼10 cm(2) V(-1) s(-1)), the demonstrated circuit performance has been limited to 800 kHz or less. Herein, we report solution-processed high-speed thin-film transistors (TFTs) and integrated circuits with an operation frequency beyond the megahertz region on 4 inch glass. The TFTs can be fabricated from an amorphous indium gallium zinc oxide/single-walled carbon nanotube (a-IGZO/SWNT) composite thin film with high yield and high carrier mobility of >70 cm(2) V(-1) s(-1). On-chip microwave measurements demonstrate that these TFTs can deliver an unprecedented operation frequency in solution-processed semiconductors, including an extrinsic cut-off frequency (f(T) = 102 MHz) and a maximum oscillation frequency (f(max) = 122 MHz). Ring oscillators further demonstrated an oscillation frequency of 4.13 MHz, for the first time, realizing megahertz circuit operation from solution-processed semiconductors. Our studies represent an important step toward high-speed solution-processed thin film electronics.
NASA Astrophysics Data System (ADS)
Zhu, Dan; Wu, Zu-Hui; Chen, Ji-Yao; Zhou, Lu-Wei
2013-06-01
We apply electric fields at different frequencies of 0.1, 1, 10 and 100 kHz to the rat basophilic leukemia (RBL) mast cells in calcium-containing or calcium-free buffers. The stimuli cause changes of the intracellular calcium ion concentration [Ca2+]i as well as the histamine. The [Ca2+]i increases when the frequency of the external electric field increases from 100 Hz to 10 kHz, and then decreases when the frequency further increases from 10 kHz to 100 kHz, showing a peak at 100 kHz. A similar frequency dependence of the histamine release is also found. The [Ca2+]i and the histamine releases at 100 Hz are about the same as the values of the control group with no electrical stimulation. The ruthenium red (RR), an inhibitor to the TRPV (transient receptor potential (TRP) family V) channels across the cell membrane, is used in the experiment to check whether the electric field stimuli act on the TRPV channels. Under an electric field of 10 kHz, the [Ca2+]i in a calcium-concentration buffer is about 3.5 times as much as that of the control group with no electric stimulation, while the [Ca2+]i in a calcium-free buffer is only about 2.2 times. Similar behavior is also found for the histamine release. RR blockage effect on the [Ca2+]i decrease is statistically significant (~75%) when mast cells in the buffer with calcium are stimulated with a 10 kHz electric field in comparison with the result without the RR treatment. This proves that TRPVs are the channels that calcium ions inflow through from the extracellular environment under electrical stimuli. Under this condition, the histamine is also released following a similar way. We suggest that, as far as an electric stimulation is concerned, an application of ac electric field of 10 kHz is better than other frequencies to open TRPV channels in mast cells, and this would cause a significant calcium influx resulting in a significant histamine release, which could be one of the mechanisms for electric therapy.
NASA Astrophysics Data System (ADS)
Zhang, Bin; Gan, Yi; Xu, Chang-Qing
2018-06-01
The field sequential modulation of a Nd:YVO4/MgO:PPLN intra-cavity, frequency doubling green laser was studied. The modulation frequency was set at 1 kHz and the duty cycle was changed from 20% to CW operation. It was shown that the quasi-phase matched (QPM) temperature decreases with an increase of the modulation duty cycle, and in turn causing the peak efficiency to rise. It was found that the temperature change in MgO:PPLN and the thermal lens effect in Nd:YVO4 crystal were the respective origins of these observed experimental phenomena.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Falferi, P.; Mezzena, R.; Vitale, S.
1997-08-01
The coupling effects of a commercial dc superconducting quantum interference device (SQUID) to an electrical LC resonator which operates at audio frequencies ({approx}1kHz) with quality factors Q{approx}10{sup 6} are presented. The variations of the resonance frequency of the resonator as functions of the flux applied to the SQUID are due to the SQUID dynamic inductance in good agreement with the predictions of a model. The variations of the quality factor point to a feedback mechanism between the output of the SQUID and the input circuit. {copyright} {ital 1997 American Institute of Physics.}
Fang, Liang; Wang, Ding; Li, Yongtao; Cheng, Zhaolong; Pine, Matthew K; Wang, Kexiong; Li, Songhai
2015-01-01
The clicks of Yangtze finless porpoises (Neophocaena asiaeorientalis asiaeorientalis) from 7 individuals in the tank of Baiji aquarium, 2 individuals in a netted pen at Shishou Tian-e-zhou Reserve and 4 free-ranging individuals at Tianxingzhou were recorded using a broadband digital recording system with four element hydrophones. The peak-to-peak apparent source level (ASL_pp) of clicks from individuals at the Baiji aquarium was 167 dB re 1 μPa with mean center frequency of 133 kHz, -3dB bandwidth of 18 kHz and -10 dB duration of 58 μs. The ASL_pp of clicks from individuals at the Shishou Tian-e-zhou Reserve was 180 dB re 1 μPa with mean center frequency of 128 kHz, -3dB bandwidth of 20 kHz and -10 dB duration of 39 μs. The ASL_pp of clicks from individuals at Tianxingzhou was 176 dB re 1 μPa with mean center frequency of 129 kHz, -3dB bandwidth of 15 kHz and -10 dB duration of 48 μs. Differences between the source parameters of clicks among the three groups of finless porpoises suggest these animals adapt to their echolocation signals depending on their surroundings.
NASA Astrophysics Data System (ADS)
Kuroda, Kazuaki; LCGT Collaboration
Piezoelectric materials are just now, within the last decade, coming into their own as a commercial material. Capable of converting energy from the mechanical domain to the electrical domain; piezos are ideal sensors, vibration dampers, energy harvesters, and actuators. Frequency rectification, or the conversion of small, high frequency piezoelectric vibrations into useful low frequency actuation, is required to obtain widespread industrial use of piezoelectric devices. This work examines three manifestations of piezoelectric frequency rectification: energy harvesting, a hydraulic motor, and friction based commercial-off-the-shelf motors. An energy harvesting device is developed, manufactured, and tested in this work, resulting in the development of a high Energy Density (J/m 3), high Power Density (W/m3) energy harvester. The device is shown to have an Energy Density nearly twice that of a similar conventional energy harvesting device. The result of this work is the development of an energy harvesting system that generates more energy in a given volume of piezoelectric material, opening the possibility of miniaturization of energy harvesting devices. Also presented is an effort to integrate a high frequency, high flow rate micromachined valve array into a PiezoHydraulic Pump (PHP), enabling resonant operation of the PHP. Currently, the device is limited by the resonant frequency of the proprietary passive check valves. The PHP is fully characterized, and the microvalve array is tested to determine its resonant frequency in a fluid medium. The valve testing resulted in a resonant frequency of 6.9 kHz, slightly lower than the target operating frequency of 10 kHz. Finally, the results of an examination of frequency rectification as applied to COTS piezoelectric motors are presented. Currently, motors are almost universally characterized based upon their available mechanical power. A better comparison is one based upon the actual Energy Density of the piezoelectric material utilized in the motor compared to the theoretical maximum Energy Density under the motor operating conditions (i.e., frequency, applied electric field). The result of this work is a more descriptive metric to evaluate piezoelectric motors that provides information on the effectiveness of the motor drive train; that is, how effectively the motion of the piezoelectric is transferred to the outside world.
The Influence of High-Frequency Envelope Information on Low-Frequency Vowel Identification in Noise
2016-01-01
Vowel identification in noise using consonant-vowel-consonant (CVC) logatomes was used to investigate a possible interplay of speech information from different frequency regions. It was hypothesized that the periodicity conveyed by the temporal envelope of a high frequency stimulus can enhance the use of the information carried by auditory channels in the low-frequency region that share the same periodicity. It was further hypothesized that this acts as a strobe-like mechanism and would increase the signal-to-noise ratio for the voiced parts of the CVCs. In a first experiment, different high-frequency cues were provided to test this hypothesis, whereas a second experiment examined more closely the role of amplitude modulations and intact phase information within the high-frequency region (4–8 kHz). CVCs were either natural or vocoded speech (both limited to a low-pass cutoff-frequency of 2.5 kHz) and were presented in stationary 3-kHz low-pass filtered masking noise. The experimental results did not support the hypothesized use of periodicity information for aiding low-frequency perception. PMID:26730702
Ultralow-frequency-noise stabilization of a laser by locking to an optical fiber-delay line.
Kéfélian, Fabien; Jiang, Haifeng; Lemonde, Pierre; Santarelli, Giorgio
2009-04-01
We report the frequency stabilization of an erbium-doped fiber distributed-feedback laser using an all-fiber-based Michelson interferometer of large arm imbalance. The interferometer uses a 1 km SMF-28 optical fiber spool and an acousto-optic modulator allowing heterodyne detection. The frequency-noise power spectral density is reduced by more than 40 dB for Fourier frequencies ranging from 1 Hz to 10 kHz, corresponding to a level well below 1 Hz2/Hz over the entire range; it reaches 10(-2) Hz2/Hz at 1 kHz. Between 40 Hz and 30 kHz, the frequency noise is shown to be comparable to the one obtained by Pound-Drever-Hall locking to a high-finesse Fabry-Perot cavity. Locking to a fiber delay line could consequently represent a reliable, simple, and compact alternative to cavity stabilization for short-term linewidth reduction.
Nd:GdVO4 ring laser pumped by laser diodes
NASA Astrophysics Data System (ADS)
Hao, E. J.; Li, T.; Wang, Z. D.; Zhang, Y.
2013-02-01
The design and operation of a laser diode-pumped Nd:GdVO4 ring laser is described. A composite crystal (Nd:GdVO4/YVO4) with undoped ends is single-end pumped by a fiber-coupled laser diode (LD) at 808 nm. A four-mirror ring cavity is designed to keep the laser operating unidirectionally, which eliminates spatial hole burning in the standing-wave cavity. This laser can operate either as continuous wave (CW) or Q-switched. The single-frequency power obtained was 9.1 W at 1063 nm. Q-switched operation produced 0.23 mJ/pulse at 20 kHz in the fundamental laser.
NASA Technical Reports Server (NTRS)
Freed, C.; Bielinski, J. W.; Lo, W.
1983-01-01
Quantum phase noise limited Lorentzian power spectral densities were achieved with tunable lead-salt diode lasers. Linewidths as narrow as 22 kHz were observed. A truly programmable infrared synthesizer was produced by frequency-offset-locking the tunable diode lasers to the combination of a stable CO2 (or CO) reference laser and a programmable microwave frequency synthesizer. Absolute frequency accuracy and reproducibility of about + or - 30 kHz (0.000001 kaysers) relative to the primary Cs frequency standard may now be obtained with this technique.
A MEMS-based high frequency x-ray chopper.
Siria, A; Dhez, O; Schwartz, W; Torricelli, G; Comin, F; Chevrier, J
2009-04-29
Time-resolved x-ray experiments require intensity modulation at high frequencies (advanced rotating choppers have nowadays reached the kHz range). We here demonstrate that a silicon microlever oscillating at 13 kHz with nanometric amplitude can be used as a high frequency x-ray chopper. We claim that using micro-and nanoelectromechanical systems (MEMS and NEMS), it will be possible to achieve higher frequencies in excess of hundreds of megahertz. Working at such a frequency can open a wealth of possibilities in chemistry, biology and physics time-resolved experiments.
Correlation Between Low Frequency Auroral Kilometric Radiation (AKR) and Auroral Structures
NASA Technical Reports Server (NTRS)
Paxamickas, Katherine A.; Green, James L.; Gallagher, Dennis L.; Boardsen, Scott; Mende, Stephen; Frey, Harald; Reinisch, Bodo W.
2005-01-01
Auroral Kilometric Radiation (AKR) is a radio wave emission that has long been associated with auroral activity. AKR is normally observed in the frequency range from -60 - 600 kHz. Low frequency AKR (or LF-AKR) events are characterized as a rapid extension of AKR related emissions to 30 kHz or lower in frequency for typically much less than 10 minutes. LF-AKR emissions predominantly occur within a frequency range of 20 kHz - 30 kHz, but there are LF-AKR related emissions that reach to a frequency of 5 kHz. This study correlates all instances of LF-AKR events during the first four years of observations from the IMAGE spacecraft's Radio Plasma Imager (WI) instrument with auroral observations from the wideband imaging camera (WIC) onboard IMAGE. The correlation between LF-AKR occurrence and WIC auroral observations shows that in the 295 confirmed cases of LF-AKR emissions, bifurcation of the aurora is seen in 74% of the cases. The bifurcation is seen in the dusk and midnight sectors of the auroral oval, where AKR is believed to be generated. The polarization of these LF-AKR emissions has yet to be identified. Although LF-AKR may not be the only phenomena correlated with bifurcated auroral structures, bifurcation will occur in most instances when LF-AKR is observed. The LF-AKR emissions may be an indicator of specific auroral processes sometimes occurring during storm-time conditions in which field-aligned density cavities extend a distance of perhaps 5-6 RE tailward from the Earth for a period of 10 minutes or less.
2011-01-01
Vocal production requires complex planning and coordination of respiratory, laryngeal, and vocal tract movements, which are incompletely understood in most mammals. Rats produce a variety of whistles in the ultrasonic range that are of communicative relevance and of importance as a model system, but the sources of acoustic variability were mostly unknown. The goal was to identify sources of fundamental frequency variability. Subglottal pressure, tracheal airflow, and electromyographic (EMG) data from two intrinsic laryngeal muscles were measured during 22-kHz and 50-kHz call production in awake, spontaneously behaving adult male rats. During ultrasound vocalization, subglottal pressure ranged between 0.8 and 1.9 kPa. Pressure differences between call types were not significant. The relation between fundamental frequency and subglottal pressure within call types was inconsistent. Experimental manipulations of subglottal pressure had only small effects on fundamental frequency. Tracheal airflow patterns were also inconsistently associated with frequency. Pressure and flow seem to play a small role in regulation of fundamental frequency. Muscle activity, however, is precisely regulated and very sensitive to alterations, presumably because of effects on resonance properties in the vocal tract. EMG activity of cricothyroid and thyroarytenoid muscle was tonic in calls with slow or no fundamental frequency modulations, like 22-kHz and flat 50-kHz calls. Both muscles showed brief high-amplitude, alternating bursts at rates up to 150 Hz during production of frequency-modulated 50-kHz calls. A differentiated and fine regulation of intrinsic laryngeal muscles is critical for normal ultrasound vocalization. Many features of the laryngeal muscle activation pattern during ultrasound vocalization in rats are shared with other mammals. PMID:21832032
New ultra-high resolution dye laser spectrometer utilizing a non-tunable reference resonator
NASA Astrophysics Data System (ADS)
Helmcke, J.; Snyder, J. J.; Morinaga, A.; Mensing, F.; Gläser, M.
1987-06-01
A new dye laser spectrometer utilizing a non-tunable reference resonator is described. The resonator consists of two Zerodur mirrors optically contacted to a Zerodur spacer. Frequency scanning of the laser is provided by acoustooptic modulation. Residual drifts of the resonator frequency — measured on line — are compensated automatically by corresponding corrections of the modulation frequency. The stability during several hours and the resettability of the dye laser frequency are±2.5 kHz and±10 kHz, respectively.
NASA Astrophysics Data System (ADS)
Jeon, Hyejin; Jang, Jongmoon; Kim, Sangwon; Choi, Hongsoo
2018-03-01
In this study, we present a piezoelectric artificial basilar membrane (ABM) composed of a 10-channel aluminum nitride beam array. Each beam varies in length from 1306 to 3194 μm for mimicking the frequency selectivity of the cochlea. To characterize the frequency selectivity of the ABM, we measured the mechanical displacement and piezoelectric output while applying acoustic stimulus at 100 dB sound pressure level in the range of 500 Hz-40 kHz. The resonance frequencies measured by mechanical displacement and piezoelectric output were in the range of 10.56-36.5 and 10.9-37.0 kHz, respectively. In addition, the electrical stimulus was applied to the ABMs to compare the mechanical responses in air and fluid. The measured resonance frequencies were in the range of 11.1-47.7 kHz in the air and 3.10-11.9 kHz in the fluid. Understanding the characteristics of the ABM is important for its potential use as a key technology for auditory prostheses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kongpiboolkid, Watcharapon; Mongkolnavin, Rattachat; Plasma Technology and Nuclear Fusion Research Unit, Chulalongkorn University, Bangkok
2015-04-24
Non-thermal properties of Argon glow discharge operating with various operating pressures were measured and presented in this work. The Argon plasma is produced by a parallel conducting electrodes coupling with a high voltage AC power supply. The power supply can generate high AC voltage at various frequencies. The frequencies for the operation are in the range of a few kHz. The system is capable of generating electric field between the two metal electrodes discharge system. The characteristics of plasma produced were measured by optical emission spectroscopy (OES) technique where electron temperature (T{sub e}) and electron number density (n{sub e}) canmore » be determined by line intensity ratio method. The value of electron number density was then determined from the Saha-Eggert equation. Our results show that the electron number density of the discharge obtained is of the order of 10{sup −17} − 10{sup −18} m{sup −3} where the electron temperature is between 1.00−2.00 eV for various operating frequencies used which are in good agreement with similar results published earlier.« less
Coil design considerations for a high-frequency electromagnetic induction sensing instrument
NASA Astrophysics Data System (ADS)
Sigman, John B.; Barrowes, Benjamin E.; Wang, Yinlin; Bennett, Hollis J.; Simms, Janet E.; Yule, Donald E.; O'Neill, Kevin; Shubitidze, Fridon
2016-05-01
Intermediate electrical conductivity (IEC) materials (101S/m < σ < 104S/m), such as carbon fiber (CF), have recently been used to make smart bombs. In addition, homemade improvised explosive devices (IED) can be produced with low conducting materials (10-4S/m < σ < 1S/m), such as Ammonium Nitrate (AN). To collect unexploded ordnance (UXO) from military training ranges and thwart deadly IEDs, the US military has urgent need for technology capable of detection and identification of subsurface IEC objects. Recent analytical and numerical studies have showed that these targets exhibit characteristic quadrature response peaks at high induction frequencies (100kHz - 15MHz, the High Frequency Electromagnetic Induction (HFEMI) band), and they are not detectable with traditional ultra wideband (UWB) electromagnetic induction (EMI) metal detectors operating between 100Hz - 100kHz. Using the HFEMI band for induction sensing is not so simple as driving existing instruments at higher frequencies, though. At low frequency, EMI systems use more wire turns in transmit and receive coils to boost signal-to-noise ratios (SNR), but at higher frequencies, the transmitter current has non-uniform distribution along the coil length. These non-uniform currents change the spatial distribution of the primary magnetic field and disturb axial symmetry and thwart established approaches for inferring subsurface metallic object properties. This paper discusses engineering tradeoffs for sensing with a broader band of frequencies ever used for EMI sensing, with particular focus on coil geometries.
Development of a long-gauge vibration sensor
NASA Astrophysics Data System (ADS)
Kung, Peter; Comanici, Maria I.; Li, Qian; Zhang, Yiwei
2014-11-01
Recently, we found that by terminating a long length of fiber of up to 1 km with an in-fiber cavity structure, the entire structure can detect vibrations over a frequency range from 5 Hz to 100 Hz. We want to determine whether the structure (including packaging) can be optimized to detect vibrations at even higher frequencies. The structure can be used as a distributed vibration sensor mounted on large motors and other rotating machines to capture the entire frequency spectrum of the associated vibration signals, and therefore, replace the many accelerometers, which add to the maintenance cost. Similarly, it will help detect in-slot vibrations which cause intermittent contact leading to sparking under high voltages inside air-cooled generators. However, that will require the sensor to detect frequencies associated with vibration sparking, ranging from 6 kHz to 15 kHz. Then, at even higher frequencies, the structure can be useful to detect acoustic vibrations (30 kHz to 150 kHz) associated with partial discharge (PD) in generators and transformers. Detecting lower frequencies in the range 2 Hz to 200 Hz makes the sensor suitable for seismic studies and falls well into the vibrations associated with rotating machines. Another application of interest is corrosion detection in large reenforced concrete structures by inserting the sensor along a long hole drilled around structures showing signs of corrosion. The frequency response for the proposed long-gauge vibration sensor depends on packaging.
Growth of suppression in humans based on distortion-product otoacoustic emission measurements
Gorga, Michael P.; Neely, Stephen T.; Kopun, Judy; Tan, Hongyang
2011-01-01
Distortion-product otoacoustic emissions (DPOAEs) were used to describe suppression growth in normal-hearing humans. Data were collected at eight f2 frequencies ranging from 0.5 to 8 kHz for L2 levels ranging from 10 to 60 dB sensation level. For each f2 and L2 combination, suppression was measured for nine or eleven suppressor frequencies (f3) whose levels varied from −20 to 85 dB sound pressure level (SPL). Suppression grew nearly linearly when f3 ≈ f2, grew more rapidly for f3 < f2, and grew more slowly for f3 > f2. These results are consistent with physiological and mechanical data from lower animals, as well as previous DPOAE data from humans, although no previous DPOAE study has described suppression growth for as wide a range of frequencies and levels. These trends were evident for all f2 and L2 combinations; however, some exceptions were noted. Specifically, suppression growth rate was less steep as a function of f3 for f2 frequencies ≤1 kHz. Thus, despite the qualitative similarities across frequency, there were quantitative differences related to f2, suggesting that there may be subtle differences in suppression for frequencies above 1 kHz compared to frequencies below 1 kHz. PMID:21361439
NASA Technical Reports Server (NTRS)
Serafini, J. S.; Terdan, F. F.
1973-01-01
Measurements of the RMS magnitude, spectra and cross-correlations for the fluctuations in the beam, discharge and neutralizer keeper currents are presented for a 30-cm diameter dished grid ion thrustor for a range of magnetic baffle currents and up to 2.0 amperes beam current. The ratio of RMS to mean ion beam current varied from 0.04 to 0.23. The spectra of the amplitudes of the beam and discharge current fluctuations were taken up to 9 MHz and show that the predominant amplitudes occur at frequencies of 10 kHz or below. The fall-off with increasing frequency is rapid. Frequencies above 100 kHz the spectral levels are 45 kb or more below the maximum peak amplitudes. The cross-correlations revealed the ion beam fluctuations to have large radial and axial scales which implied that the beam fluctuates as a whole or 'in-phase.' The cross-correlations of the beam and neutralizer keeper current fluctuations indicated the neutralizer contributions to the beam fluctuations to be small, but not negligible. The mode of operation of the thrustor (values of beam and magnetic baffle currents) was significant in determining the RMS magnitude and spectral shape of the beam fluctuations. The major oscillations were not found to be directly dependent on the power conditioner inverter frequencies.
Steube, Natalie; Nowotny, Manuela; Pilz, Peter K. D.; Gaese, Bernhard H.
2016-01-01
The acoustic startle response (ASR) and its modulation by non-startling prepulses, presented shortly before the startle-eliciting stimulus, is a broadly applied test paradigm to determine changes in neural processing related to auditory or psychiatric disorders. Modulation by a gap in background noise as a prepulse is especially used for tinnitus assessment. However, the timing and frequency-related aspects of prepulses are not fully understood. The present study aims to investigate temporal and spectral characteristics of acoustic stimuli that modulate the ASR in rats and gerbils. For noise-burst prepulses, inhibition was frequency-independent in gerbils in the test range between 4 and 18 kHz. Prepulse inhibition (PPI) by noise-bursts in rats was constant in a comparable range (8–22 kHz), but lower outside this range. Purely temporal aspects of prepulse–startle-interactions were investigated for gap-prepulses focusing mainly on gap duration. While very short gaps had no (rats) or slightly facilitatory (gerbils) influence on the ASR, longer gaps always had a strong inhibitory effect. Inhibition increased with durations up to 75 ms and remained at a high level of inhibition for durations up to 1000 ms for both, rats and gerbils. Determining spectral influences on gap-prepulse inhibition (gap-PPI) revealed that gerbils were unaffected in the limited frequency range tested (4–18 kHz). The more detailed analysis in rats revealed a variety of frequency-dependent effects. Gaps in pure-tone background elicited constant and high inhibition (around 75%) over a broad frequency range (4–32 kHz). For gaps in noise-bands, on the other hand, a clear frequency-dependency was found: inhibition was around 50% at lower frequencies (6–14 kHz) and around 70% at high frequencies (16–20 kHz). This pattern of frequency-dependency in rats was specifically resulting from the inhibitory effect by the gaps, as revealed by detailed analysis of the underlying startle amplitudes. An interaction of temporal and spectral influences, finally, resulted in higher inhibition for 500 ms gaps than for 75 ms gaps at all frequencies tested. Improved prepulse paradigms based on these results are well suited to quantify the consequences of central processing disorders. PMID:27445728
EFFECTS OF LOW-FREQUENCY ULTRASOUND ON MICROCIRCULATION IN VENOUS LEG ULCERS
Wollina, Uwe; Heinig, Birgit; Naumann, Gunther; Scheibe, Armin; Schmidt, Wolf-Dieter; Neugebauer, Reimund
2011-01-01
Background: Therapeutic low-frequency ultrasound (US) has been used for many years to improve wound healing in chronic wounds like venous leg ulcers. No human data are available for the possible effects of single US applications on microcirculation and their frequency-dependency. Aims: To investigated the role of therapeutic low-frequency US on microcirculation of venous leg ulcers in vivo. Patients and Methods: This is a pilot study on an inpatient basis. We use a newly developed low-frequency continuous-wave US-equipment composed of a US transducer based on piezo-fiber composites that allow the change of frequency. In this study, we apply US of 34 kHz, 53.5 kHz, and 75 kHz respectively. Twelve patients with chronic venous leg ulcers are analyzed. As an adjunct to good ulcer care, therapeutic US is applied, non-contacting, once a day, in a subaqual position for 10 minutes. Microcirculation is assessed in the ulcers adjacent to skin before US-therapy, immediately after the treatment and 30 minutes later. We use a micro-light guide spectrophotometer (O2C, LEA Medizintechnik GmbH, Gieίen, Germany) for calculation of blood flow velocity, hemoglobin oxygen saturation (SCO2) and relative hemoglobin concentration (rHb) in 2 and 8 mm depth. Contact-free remission spectroscopy (SkinREM3, Color Control Chemnitz GmbH, Chemnitz, Germany) allows contact free measurements in the VIS-NIR range of the spectrum (400 ± 1600 nm). Results: It is seen that therapeutic US is well tolerated. One patient dropped out from a treatment series since he developed erysipelas responding to standard antibiotic. Effects were seen at 34 kHz only. The SO2 values increased after single US application. The values for rHb were higher in the superficial layer of the wound bed (depth 2 mm) compared to deeper parts (8 mm depth). US treatment did not result in significant changes of rHb and blood cell velocity. The data obtained by remission spectroscopy disclose an increase of oxygenized hemoglobin. Conclusions: The major findings are that continuous-wave low-frequency US of 34 kHz, but not, 53.5 kHz or 75 kHz, has a temporary stimulatory effect on microcirculation mainly due to an improved oxygenation. Further studies with treatment series are necessary. PMID:21716543
NASA Astrophysics Data System (ADS)
Li, Xuechen; Liu, Rui; Jia, Pengying; Wu, Kaiyue; Ren, Chenhua; Yin, Zengqian
2018-01-01
A one-dimensional fluid model in atmospheric pressure argon is employed to investigate the influence of the driving frequency on dielectric barrier discharge modes excited by a triangle voltage. Results indicate that a stepped discharge mode is obtained with a low driving frequency of 35 kHz. The current amplitude increases, while its plateau duration decreases with increasing the frequency. The stepped discharge transits into a multi-pulsed mode when the frequency is increased to 80 kHz. With its further increment, the pulse number decreases, and a double-pulsed discharge is realized at 90 kHz, which finally transits to a single-pulsed discharge. Through analyzing spatial distributions of electron density, ion density, and electric field, it can be concluded that the discharge regime transits from a Townsend-like discharge to a glow discharge with increasing the frequency. The regime transition is further verified by analyzing voltage-current curves. These simulated results are consistent with the experimental phenomena.
Magnetosheath electrostatic turbulence
NASA Technical Reports Server (NTRS)
Rodriquez, P.
1977-01-01
The spectrum of electrostatic plasma waves in the terrestrial magnetosheath was studied using the plasma wave experiment on the IMP-6 satellite. Electrostatic plasma wave turbulence is almost continuously present throughout the magnetosheath with broadband (20 Hz- 70 kHz) r.m.s. field intensities typically 0.01 - 1.0 millivolts/m. Peak intensities of about 1.0 millivolts/m near the electron plasma frequency (30 - 60 kHz) were detected occasionally. The components usually identified in the spectrum of magnetosheath electrostatic turbulence include a high frequency ( or = 30 kHz) component peaking at the electron plasma frequency f sub pe, a low frequency component with a broad intensity maximum below the nominal ion plasma frequency f sub pi (approximately f sub pe/43), and a less well defined intermediate component in the range f sub pi f f sub pe. The intensity distribution of magnetosheath electrostatic turbulence clearly shows that the low frequency component is associated with the bow shock, suggesting that the ion heating begun at the shock continues into the downstream magnetosheath.
Air-Leak Effects on Ear-Canal Acoustic Absorbance
Rasetshwane, Daniel M.; Kopun, Judy G.; Gorga, Michael P.; Neely, Stephen T.
2015-01-01
Objective: Accurate ear-canal acoustic measurements, such as wideband acoustic admittance, absorbance, and otoacoustic emissions, require that the measurement probe be tightly sealed in the ear canal. Air leaks can compromise the validity of the measurements, interfere with calibrations, and increase variability. There are no established procedures for determining the presence of air leaks or criteria for what size leak would affect the accuracy of ear-canal acoustic measurements. The purpose of this study was to determine ways to quantify the effects of air leaks and to develop objective criteria to detect their presence. Design: Air leaks were simulated by modifying the foam tips that are used with the measurement probe through insertion of thin plastic tubing. To analyze the effect of air leaks, acoustic measurements were taken with both modified and unmodified foam tips in brass-tube cavities and human ear canals. Measurements were initially made in cavities to determine the range of critical leaks. Subsequently, data were collected in ears of 21 adults with normal hearing and normal middle-ear function. Four acoustic metrics were used for predicting the presence of air leaks and for quantifying these leaks: (1) low-frequency admittance phase (averaged over 0.1–0.2 kHz), (2) low-frequency absorbance, (3) the ratio of compliance volume to physical volume (CV/PV), and (4) the air-leak resonance frequency. The outcome variable in this analysis was the absorbance change (Δabsorbance), which was calculated in eight frequency bands. Results: The trends were similar for both the brass cavities and the ear canals. ΔAbsorbance generally increased with air-leak size and was largest for the lower frequency bands (0.1–0.2 and 0.2–0.5 kHz). Air-leak effects were observed in frequencies up to 10 kHz, but their effects above 1 kHz were unpredictable. These high-frequency air leaks were larger in brass cavities than in ear canals. Each of the four predictor variables exhibited consistent dependence on air-leak size. Low-frequency admittance phase and CV/PV decreased, while low-frequency absorbance and the air-leak resonance frequency increased. Conclusion: The effect of air leaks can be significant when their equivalent diameter exceeds 0.01 in. The observed effects were greatest at low frequencies where air leaks caused absorbance to increase. Recommended criteria for detecting air leaks include the following: when the frequency range of interest extends as low as 0.1 kHz, low-frequency absorbance should be ≤0.20 and low-frequency admittance phase ≥61 degrees. For frequency ranges as low as 0.2 kHz, low-frequency absorbance should be ≤0.29 and low-frequency admittance phase ≥44 degrees. PMID:25170779
Air-leak effects on ear-canal acoustic absorbance.
Groon, Katherine A; Rasetshwane, Daniel M; Kopun, Judy G; Gorga, Michael P; Neely, Stephen T
2015-01-01
Accurate ear-canal acoustic measurements, such as wideband acoustic admittance, absorbance, and otoacoustic emissions, require that the measurement probe be tightly sealed in the ear canal. Air leaks can compromise the validity of the measurements, interfere with calibrations, and increase variability. There are no established procedures for determining the presence of air leaks or criteria for what size leak would affect the accuracy of ear-canal acoustic measurements. The purpose of this study was to determine ways to quantify the effects of air leaks and to develop objective criteria to detect their presence. Air leaks were simulated by modifying the foam tips that are used with the measurement probe through insertion of thin plastic tubing. To analyze the effect of air leaks, acoustic measurements were taken with both modified and unmodified foam tips in brass-tube cavities and human ear canals. Measurements were initially made in cavities to determine the range of critical leaks. Subsequently, data were collected in ears of 21 adults with normal hearing and normal middle-ear function. Four acoustic metrics were used for predicting the presence of air leaks and for quantifying these leaks: (1) low-frequency admittance phase (averaged over 0.1-0.2 kHz), (2) low-frequency absorbance, (3) the ratio of compliance volume to physical volume (CV/PV), and (4) the air-leak resonance frequency. The outcome variable in this analysis was the absorbance change (Δabsorbance), which was calculated in eight frequency bands. The trends were similar for both the brass cavities and the ear canals. ΔAbsorbance generally increased with air-leak size and was largest for the lower frequency bands (0.1-0.2 and 0.2-0.5 kHz). Air-leak effects were observed in frequencies up to 10 kHz, but their effects above 1 kHz were unpredictable. These high-frequency air leaks were larger in brass cavities than in ear canals. Each of the four predictor variables exhibited consistent dependence on air-leak size. Low-frequency admittance phase and CV/PV decreased, while low-frequency absorbance and the air-leak resonance frequency increased. The effect of air leaks can be significant when their equivalent diameter exceeds 0.01 in. The observed effects were greatest at low frequencies where air leaks caused absorbance to increase. Recommended criteria for detecting air leaks include the following: when the frequency range of interest extends as low as 0.1 kHz, low-frequency absorbance should be ≤0.20 and low-frequency admittance phase ≥61 degrees. For frequency ranges as low as 0.2 kHz, low-frequency absorbance should be ≤0.29 and low-frequency admittance phase ≥44 degrees.
Narrow-band erbium-doped fibre linear–ring laser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kolegov, A A; Sofienko, G S; Minashina, L A
2014-01-31
We have demonstrated a narrow-band linear – ring fibre laser with an output power of 15 mW at a wavelength of 1.55 μm and an emission bandwidth less than 5 kHz. The laser frequency is stabilised by an unpumped active fibre section and fibre Bragg grating. The fibre laser operates in a travelling wave mode, which allows the spatial hole burning effect to be avoided. At a certain pump power level, the laser switches from continuous mode to repetitivepulse operation, corresponding to relaxation oscillations. (control of laser radiation parameters)
Note: A simple multi-channel optical system for modulation spectroscopies.
Solís-Macías, J; Sánchez-López, J D; Castro-García, R; Flores-Camacho, J M; Flores-Rangel, G; Ciou, Jian-Jhih; Chen, Kai-Wei; Chen, Chang-Hsiao; Lastras-Martínez, L F; Balderas-Navarro, R E
2017-12-01
Photoreflectance-difference (PR/PRD) and reflectance-difference (RD) spectroscopies employ synchronic detection usually with lock-in amplifiers operating at moderate (200-1000 Hz) and high (50-100 KHz) modulation frequencies, respectively. Here, we report a measurement system for these spectroscopies based on a multichannel CCD spectrometer without a lock-in amplifier. In the proposed scheme, a typical PRD or RD spectrum consists of numerical subtractions between a thousand CCD captures recorded, while a photoelastic modulator is either operating or inhibited. This is advantageous and fits the slow response of CCD detectors to high modulation frequencies. The resulting spectra are processed with Savitzky-Golay filtering and compared well with those measured with conventional scanning systems based on lock-in amplifiers.
Keefe, D H; Bulen, J C; Campbell, S L; Burns, E M
1994-01-01
The diffuse-field pressure transfer function from a reverberant field to the ear canal of human infants, ages 1, 3, 6, 12, and 24 months, has been measured from 125-10700 Hz. The source was a loudspeaker using pink noise, and the diffuse-field pressure and the ear-canal pressure were simultaneously measured using a spatial averaging technique in a reverberant room. The results in most subjects show a two-peak structure in the 2-6-kHz range, corresponding to the ear-canal and concha resonances. The ear-canal resonance frequency decreases from 4.4 kHz at age 1 month to 2.9 kHz at age 24 months. The concha resonance frequency decreases from 5.5 kHz at age 1 month to 4.5 kHz at age 24 months. Below 2 kHz, the diffuse-field transfer function shows effects due to the torsos of the infant and parent, and varies with how the infant is held. Comparisons are reported of the diffuse-field absorption cross section for infants relative to adults. This quantity is a measure of power absorbed by the middle ear from a diffuse sound field, and large differences are observed in infants relative to adults. The radiation efficiencies of the infant and the adult ear are small at low frequencies, near unity at midfrequencies, and decrease at higher frequencies. The process of ear-canal development is not yet complete at age 24 months. The results have implications for experiments on hearing in infants.
Generating an AC amplitude magnetic flux density value up to 150 μT at a frequency up to 100 kHz
NASA Astrophysics Data System (ADS)
Ulvr, Michal; Polonský, Jakub
2017-05-01
AC magnetic field analyzers with a triaxial coil probe are widely used by health and safety professionals, in manufacturing, and in service industries. For traceable calibration of these analyzers, it is important to be able to generate a stable, homogeneous reference AC magnetic flux density (MFD). In this paper, the generating of AC amplitude MFD value of 150 μT by single-layer Helmholtz type solenoid, described in previous work, was expanded up to a frequency of 100 kHz using the effect of serial resonance. A programmable capacitor array has been developed with a range of adjustable values from 50 pF to 51225 pF. In addition, the multi-layer search coil with a nominal area turns value of 1.3m2, used for adjusting AC MFD in the solenoid, has been modified by a transimpedance amplifier for use in a wider frequency range than up to 3 kHz. The possibility of using the programmable capacitor array up to 150 kHz has also been tested. An AC amplitude MFD value of 150 μT can be generated with expanded uncertainty better than 0.6% up to 100 kHz.
2005-06-21
266-nm, l-,W, 500-ps laser pulse from a frequency-quadrupled Nd:YAG microchip laser operating at 10 kHz. Fluorescence and elastic scattering from the...on Solid State Research xv Organization xxiii QUANTUM ELECTRONICS 1.1 Fluorescence-Cued Laser -Induced Breakdown Spectroscopy Detection of Bioaerosols...2. ELECTRO-OfI’ICAL MATERIALS AND DEVICES 2.1 Narrow-Linewidth, High-Power 1556-nm Slab-Coupled Optical Waveguide External-Cavity Laser 7 3
Compact x-ray source based on burst-mode inverse Compton scattering at 100 kHz
Graves, W. S.; Bessuille, J.; Brown, P.; ...
2014-12-01
A design for a compact x-ray light source (CXLS) with flux and brilliance orders of magnitude beyond existing laboratory scale sources is presented. The source is based on inverse Compton scattering of a high brightness electron bunch on a picosecond laser pulse. The accelerator is a novel high-efficiency standingwave linac and rf photoinjector powered by a single ultrastable rf transmitter at X-band rf frequency. The high efficiency permits operation at repetition rates up to 1 kHz, which is further boosted to 100 kHz by operating with trains of 100 bunches of 100 pC charge, each separated by 5 ns. Themore » entire accelerator is approximately 1 meter long and produces hard x rays tunable over a wide range of photon energies. The colliding laser is a Yb:YAG solid-state amplifier producing 1030 nm, 100 mJ pulses at the same 1 kHz repetition rate as the accelerator. The laser pulse is frequency-doubled and stored for many passes in a ringdown cavity to match the linac pulse structure. At a photon energy of 12.4 keV, the predicted x-ray flux is 5 × 10¹¹ photons/second in a 5% bandwidth and the brilliance is 2 × 10¹² photons/(sec mm² mrad² 0.1%) in pulses with rms pulse length of 490 fs. The nominal electron beam parameters are 18 MeV kinetic energy, 10 microamp average current, 0.5 microsecond macropulse length, resulting in average electron beam power of 180 W. Optimization of the x-ray output is presented along with design of the accelerator, laser, and x-ray optic components that are specific to the particular characteristics of the Compton scattered x-ray pulses.« less
NASA Technical Reports Server (NTRS)
Hofer, Richard R.; Jankovsky, Robert S.
2003-01-01
Recent studies of xenon Hall thrusters have shown peak efficiencies at specific impulses of less than 3000 s. This was a consequence of modern Hall thruster magnetic field topographies, which have been optimized for 300 V discharges. On-going research at the NASA Glenn Research Center is investigating this behavior and methods to enhance thruster performance. To conduct these studies, a laboratory model Hall thruster that uses a pair of trim coils to tailor the magnetic field topography for high specific impulse operation has been developed. The thruster-the NASA-173Mv2 was tested to determine how current density and magnetic field topography affect performance, divergence, and plasma oscillations at voltages up to 1000 V. Test results showed there was a minimum current density and optimum magnetic field topography at which efficiency monotonically increased with voltage. At 1000 V, 10 milligrams per second the total specific impulse was 3390 s and the total efficiency was 60.8%. Plume divergence decreased at 400-1000 V, but increased at 300-400 V as the result of plasma oscillations. The dominant oscillation frequency steadily increased with voltage, from 14.5 kHz at 300 V, to 22 kHz at 1000 V. An additional oscillatory mode in the 80-90 kHz frequency range began to appear above 500 V. The use of trim coils to modify the magnetic field improved performance while decreasing plume divergence and the frequency and magnitude of plasma oscillations.
47 CFR 80.1127 - On-scene communications.
Code of Federal Regulations, 2011 CFR
2011-10-01
... ITU-R Recommendation M.625-3, with Annex, as specified in § 80.1101. (c) The preferred frequencies in radiotelephony for on-scene communications are 156.8 MHz and 2182 kHz. The frequency 2174.5 kHz may also be used... error correcting mode in accordance with ITU-R Recommendation M.625-3, “Direct-printing Telegraph...
47 CFR 80.1135 - Transmission of maritime safety information.
Code of Federal Regulations, 2012 CFR
2012-10-01
... mentioned in this section is in accordance with ITU-R M.540-2 (incorporated by reference, see § 80.7) as...-printing telegraphy with forward error correction using the frequency 518 kHz in accordance with the international NAVTEX system (see § 80.1077). (d) The frequency 490 kHz may be used, after full implementation of...
47 CFR 80.1135 - Transmission of maritime safety information.
Code of Federal Regulations, 2010 CFR
2010-10-01
... mentioned in this section is in accordance with the ITU-R Recommendation M.540 as specified in § 80.1101. (c... error correction using the frequency 518 kHz in accordance with the international NAVTEX system (see § 80.1077). (d) The frequency 490 kHz may be used, after full implementation of the GMDSS, for the...
47 CFR 80.1135 - Transmission of maritime safety information.
Code of Federal Regulations, 2011 CFR
2011-10-01
... mentioned in this section is in accordance with the ITU-R Recommendation M.540 as specified in § 80.1101. (c... error correction using the frequency 518 kHz in accordance with the international NAVTEX system (see § 80.1077). (d) The frequency 490 kHz may be used, after full implementation of the GMDSS, for the...
47 CFR 80.1127 - On-scene communications.
Code of Federal Regulations, 2010 CFR
2010-10-01
... ITU-R Recommendation M.625-3, with Annex, as specified in § 80.1101. (c) The preferred frequencies in radiotelephony for on-scene communications are 156.8 MHz and 2182 kHz. The frequency 2174.5 kHz may also be used... error correcting mode in accordance with ITU-R Recommendation M.625-3, “Direct-printing Telegraph...
47 CFR 80.1135 - Transmission of maritime safety information.
Code of Federal Regulations, 2013 CFR
2013-10-01
... mentioned in this section is in accordance with ITU-R M.540-2 (incorporated by reference, see § 80.7) as...-printing telegraphy with forward error correction using the frequency 518 kHz in accordance with the international NAVTEX system (see § 80.1077). (d) The frequency 490 kHz may be used, after full implementation of...
47 CFR 80.1135 - Transmission of maritime safety information.
Code of Federal Regulations, 2014 CFR
2014-10-01
... mentioned in this section is in accordance with ITU-R M.540-2 (incorporated by reference, see § 80.7) as...-printing telegraphy with forward error correction using the frequency 518 kHz in accordance with the international NAVTEX system (see § 80.1077). (d) The frequency 490 kHz may be used, after full implementation of...
Portable Dynamic Pressure Calibrator
NASA Technical Reports Server (NTRS)
Wright, Morgan S.; Maynard, Everett (Technical Monitor)
1996-01-01
A portable, dynamic pressure calibrator was fabricated for use on wind tunnel models at NASA-Ames Research Center. The calibrator generates sine wave pressures at levels up to 1 PSIG P-P(168dB) at frequencies from 10Hz to 6KHz and .5 PSIG P.P (162dB) at frequencies from 6KHz to 20KHz. The calibrator consists of two units connected by a single cable. The handheld unit contains a pressure transducer, speaker, and deadman switch. This unit allows application of dynamic pressure to transducers/ports on installed wind tunnel models. The base unit contains all of power supplies, controls and displays. This unit allows amplitude and frequency to be set and verified at a safe location off of the model.
Sub-Doppler Frequency Metrology in HD for Tests of Fundamental Physics
NASA Astrophysics Data System (ADS)
Cozijn, F. M. J.; Dupré, P.; Salumbides, E. J.; Eikema, K. S. E.; Ubachs, W.
2018-04-01
Weak transitions in the (2,0) overtone band of the hydrogen deuteride molecule at λ =1.38 μ m were measured in saturated absorption using the technique of noise-immune cavity-enhanced optical heterodyne molecular spectroscopy. Narrow Doppler-free lines were interrogated with a spectroscopy laser locked to a frequency comb laser referenced to an atomic clock to yield transition frequencies [R (1 )=217105181895 (20 ) kHz ; R (2 )=219042856621 (28 ) kHz ; R (3 )=220704304951 (28 ) kHz ] at three orders of magnitude improved accuracy. These benchmark values provide a test of QED in the smallest neutral molecule, and they open up an avenue to resolve the proton radius puzzle, as well as constrain putative fifth forces and extra dimensions.
NASA Astrophysics Data System (ADS)
Popkov, Artem
2016-01-01
The article contains information about acoustic emission signals analysing using autocorrelation function. Operation factors were analysed, such as shape of signal, the origins time and carrier frequency. The purpose of work is estimating the validity of correlations methods analysing signals. Acoustic emission signal consist of different types of waves, which propagate on different trajectories in object of control. Acoustic emission signal is amplitude-, phase- and frequency-modeling signal. It was described by carrier frequency at a given point of time. Period of signal make up 12.5 microseconds and carrier frequency make up 80 kHz for analysing signal. Usage autocorrelation function like indicator the origin time of acoustic emission signal raises validity localization of emitters.
Sarria-S, Fabio A.; Morris, Glenn K.; Windmill, James F. C.; Jackson, Joseph; Montealegre-Z, Fernando
2014-01-01
This article reports the discovery of a new genus and three species of predaceous katydid (Insecta: Orthoptera) from Colombia and Ecuador in which males produce the highest frequency ultrasonic calling songs so far recorded from an arthropod. Male katydids sing by rubbing their wings together to attract distant females. Their song frequencies usually range from audio (5 kHz) to low ultrasonic (30 kHz). However, males of Supersonus spp. call females at 115 kHz, 125 kHz, and 150 kHz. Exceeding the human hearing range (50 Hz–20 kHz) by an order of magnitude, these insects also emit their ultrasound at unusually elevated sound pressure levels (SPL). In all three species these calls exceed 110 dB SPL rms re 20 µPa (at 15 cm). Males of Supersonus spp. have unusually reduced forewings (<0.5 mm2). Only the right wing radiates appreciable sound, the left bears the file and does not show a particular resonance. In contrast to most katydids, males of Supersonus spp. position and move their wings during sound production so that the concave aspect of the right wing, underlain by the insect dorsum, forms a contained cavity with sharp resonance. The observed high SPL at extreme carrier frequencies can be explained by wing anatomy, a resonant cavity with a membrane, and cuticle deformation. PMID:24901234
Fang, Liang; Wang, Ding; Li, Yongtao; Cheng, Zhaolong; Pine, Matthew K.; Wang, Kexiong; Li, Songhai
2015-01-01
The clicks of Yangtze finless porpoises (Neophocaena asiaeorientalis asiaeorientalis) from 7 individuals in the tank of Baiji aquarium, 2 individuals in a netted pen at Shishou Tian-e-zhou Reserve and 4 free-ranging individuals at Tianxingzhou were recorded using a broadband digital recording system with four element hydrophones. The peak-to-peak apparent source level (ASL_pp) of clicks from individuals at the Baiji aquarium was 167 dB re 1 μPa with mean center frequency of 133 kHz, -3dB bandwidth of 18 kHz and -10 dB duration of 58 μs. The ASL_pp of clicks from individuals at the Shishou Tian-e-zhou Reserve was 180 dB re 1 μPa with mean center frequency of 128 kHz, -3dB bandwidth of 20 kHz and -10 dB duration of 39 μs. The ASL_pp of clicks from individuals at Tianxingzhou was 176 dB re 1 μPa with mean center frequency of 129 kHz, -3dB bandwidth of 15 kHz and -10 dB duration of 48 μs. Differences between the source parameters of clicks among the three groups of finless porpoises suggest these animals adapt to their echolocation signals depending on their surroundings. PMID:26053758
PULSE AMPLITUDE DEPENDS ON kHz QPO FREQUENCY IN THE ACCRETING MILLISECOND PULSAR SAX J1808.4-3658
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bult, Peter; Van der Klis, Michiel, E-mail: p.m.bult@uva.nl
2015-01-10
We study the relation between the 300-700 Hz upper kHz quasi-periodic oscillation (QPO) and the 401 Hz coherent pulsations across all outbursts of the accreting millisecond X-ray pulsar SAX J1808.4-3658 observed with the Rossi X-ray Timing Explorer. We find that the pulse amplitude systematically changes by a factor of ∼2 when the upper kHz QPO frequency passes through 401 Hz: it halves when the QPO moves to above the spin frequency and doubles again on the way back. This establishes for the first time the existence of a direct effect of kHz QPOs on the millisecond pulsations and provides amore » new clue to the origin of the upper kHz QPO. We discuss several scenarios and conclude that while more complex explanations can not formally be excluded, our result strongly suggests that the QPO is produced by azimuthal motion at the inner edge of the accretion disk, most likely orbital motion. Depending on whether this azimuthal motion is faster or slower than the spin, the plasma then interacts differently with the neutron-star magnetic field. The most straightforward interpretation involves magnetospheric centrifugal inhibition of the accretion flow that sets in when the upper kHz QPO becomes slower than the spin.« less
Nishimura, Takuma; Hosaka, Hiroshi; Morita, Takeshi
2012-01-01
The Smooth Impact Drive Mechanism (SIDM) is a linear piezoelectric actuator that has seen practically applied to camera lens modules. Although previous SIDM actuators are easily miniaturized and enable accurate positioning, these actuators cannot actuate at high speed and cannot provide powerful driving because they are driven at an off-resonant frequency using a soft-type PZT. In the present study, we propose a resonant-type SIDM using a bolt-clamped Langevin transducer (BLT) with a hard-type PZT. The resonant-type SIDM overcomes the above-mentioned problems and high-power operation becomes possible with a very simple structure. As a result, we confirmed the operation of resonant-type SIDM by designing a bolt-clamped Langevin transducer. The properties of no-load maximum speed was 0.28m/s at driving voltages of 80V(p-p) for 44.9kHz and 48V(p-p) for 22.45kHz with a pre-load of 3.1N. Copyright © 2011 Elsevier B.V. All rights reserved.
Low frequency spectra of type III solar radio bursts
NASA Technical Reports Server (NTRS)
Weber, R. R.
1978-01-01
Flux density spectra have been determined for 91 simple type III solar bursts observed by the Goddard Space Flight Center radio astronomy experiment on the IMP-6 spacecraft during 1971 and 1972. Spectral peaks were found to occur at frequencies ranging from 44 kHz up to 2500 kHz. Half of the bursts peaked between 250 kHz and 900 kHz, corresponding to emission at solar distances of about 0.3 to 0.1 AU. Maximum burst flux density sometimes exceeds 10 to the -14th W/sq m/Hz. The primary factor controlling the spectral peak frequency of these bursts appears to be a variation in intrinsic power radiated by the source as the exciter moves outward from the sun, rather than radio propagation effects between the source and IMP-6. Thus, a burst spectrum strongly reflects the evolution of the properties of the exciting electron beam, and according to current theory, beam deceleration could help account for the observations.
Oliver, Christine M; Mawson, Raymond; Melton, Laurence D; Dumsday, Geoff; Welch, Jessica; Sanguansri, Peerasak; Singh, Tanoj K; Augustin, Mary Ann
2014-10-13
The consequences of ultrasonic pre-treatment using low (40 kHz) and medium (270 kHz) frequency (40 kHz followed by 270 kHz) on the degradation of wheat chaff (8 g 100ml(-1) acetate buffer, pH 5) were evaluated. In addition, the effects of the ultrasonic pre-treatment on the degradation of the wheat chaff when subsequently exposed to enzyme extracts from two white rot fungi (Phanerochaete chrysosporium and Trametes sp.) were investigated. Pre-treatment by sequential low and medium frequency ultrasound had a disruptive effect on the lignocellulosic matrix. Analysis of the phenolic-derived volatiles after enzymatic hydrolysis showed that biodegradation with the enzyme extract obtained from P. chrysosporium was more pronounced compared to that of the Trametes sp. The efficacy of the ultrasonic pre-treatment was attributed to increased enzyme accessibility of the cellulose fibrils due to sonication-induced disruption of the plant surface structure, as shown by changes in the microstructure. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Ahmed, Mustafa Wasir; Baishya, Manash Jyoti; Sharma, Sasanka Sekhor; Hazarika, Manash
2018-04-01
This paper presents a detecting system on power transformer in transformer winding, core and on load tap changer (OLTC). Accuracy of winding deformation is determined using kNN based classifier. Winding deformation in power transformer can be measured using sweep frequency response analysis (SFRA), which can enhance the diagnosis accuracy to a large degree. It is suggested that in the results minor deformation faults can be detected at frequency range of 1 mHz to 2 MHz. The values of RCL parameters are changed when faults occur and hence frequency response of the winding will change accordingly. The SFRA data of tested transformer is compared with reference trace. The difference between two graphs indicate faults in the transformer. The deformation between 1 mHz to 1kHz gives winding deformation, 1 kHz to 100 kHz gives core deformation and 100 kHz to 2 MHz gives OLTC deformation.
Thirumala, Parthasarathy; Frederickson, Andrew M; Balzer, Jeffrey; Crammond, Donald; Habeych, Miguel E; Chang, Yue-Fang; Sekula, Raymond F
2015-10-01
Microvascular decompression is a safe and effective procedure to treat hemifacial spasm, but the operation poses some risk to the patient's hearing. While severe sensorineural hearing loss across all frequencies occurs at a low rate in experienced hands, a recent study suggests that as many as one-half of patients who undergo this procedure may experience ipsilateral high-frequency hearing loss (HFHL), and as many as one-quarter may experience contralateral HFHL. While it has been suggested that drill-related noise may account for this finding, this study was designed to examine the effect of a number of techniques designed to protect the vestibulocochlear nerve from operative manipulation on the incidence of HFHL. Pure-tone audiometry was performed both preoperatively and postoperatively on 67 patients who underwent microvascular decompression for hemifacial spasm during the study period. A change of greater than 10 dB at either 4 kHz or 8 kHz was considered to be HFHL. Additionally, the authors analyzed intraoperative brainstem auditory evoked potentials from this patient cohort. The incidence of ipsilateral HFHL in this cohort was 7.4%, while the incidence of contralateral HFHL was 4.5%. One patient (1.5%; also included in the HFHL group) experienced an ipsilateral nonserviceable hearing loss. The reduced incidence of HFHL in this study suggests that technical modifications including performing the procedure without the use of fixed retraction may greatly reduce, but not eliminate, the occurrence of HFHL following microvascular decompression for hemifacial spasm.
NIMROD Simulations of the HIT-SI and HIT-SI3 Devices
NASA Astrophysics Data System (ADS)
Morgan, Kyle; Jarboe, Tom; Hossack, Aaron; Chandra, Rian; Everson, Chris
2017-10-01
The Helicity Injected Torus with Steady Inductive helicity injection (HIT-SI) experiment uses a set of inductively driven helicity injectors to apply non-axisymmetric current drive on the edge of the plasma, driving an axisymmetric spheromak equilibrium in a central confinement volume. Significant improvements have been made to extended MHD modeling of HIT-SI, with both the resolution of disagreement at high injector frequencies in HIT-SI in addition to successes with the new upgraded HIT-SI3 device. Previous numerical studies of HIT-SI, using a zero-beta eMHD model, focused on operations with a drive frequency of 14.5 kHz, and found reduced agreement with both the magnetic profile and current amplification at higher frequencies (30-70 kHz). HIT-SI3 has three helicity injectors which are able to operate with different mode structures of perturbations through the different relative temporal phasing of the injectors. Simulations that allow for pressure gradients have been performed in the parameter regimes of both devices using the NIMROD code and show improved agreement with experimental results, most notably capturing the observed Shafranov-shift due to increased beta observed at higher finj in HIT-SI and the variety of toroidal perturbation spectra available in HIT-SI3. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Fusion Energy Sciences under Award Number DE-FG02- 96ER54361.
Study on sound-speed dispersion in a sandy sediment at frequency ranges of 0.5-3 kHz and 90-170 kHz
NASA Astrophysics Data System (ADS)
Yu, Sheng-qi; Liu, Bao-hua; Yu, Kai-ben; Kan, Guang-ming; Yang, Zhi-guo
2017-03-01
In order to study the properties of sound-speed dispersion in a sandy sediment, the sound speed was measured both at high frequency (90-170 kHz) and low frequency (0.5-3 kHz) in laboratory environments. At high frequency, a sampling measurement was conducted with boiled and uncooked sand samples collected from the bottom of a large water tank. The sound speed was directly obtained through transmission measurement using single source and single hydrophone. At low frequency, an in situ measurement was conducted in the water tank, where the sandy sediment had been homogeneously paved at the bottom for a long time. The sound speed was indirectly inverted according to the traveling time of signals received by three buried hydrophones in the sandy sediment and the geometry in experiment. The results show that the mean sound speed is approximate 1710-1713 m/s with a weak positive gradient in the sand sample after being boiled (as a method to eliminate bubbles as much as possible) at high frequency, which agrees well with the predictions of Biot theory, the effective density fluid model (EDFM) and Buckingham's theory. However, the sound speed in the uncooked sandy sediment obviously decreases (about 80%) both at high frequency and low frequency due to plenty of bubbles in existence. And the sound-speed dispersion performs a weak negative gradient at high frequency. Finally, a water-unsaturated Biot model is presented for trying to explain the decrease of sound speed in the sandy sediment with plenty of bubbles.
Comparison of all-electric secondary power systems for civil transport
NASA Technical Reports Server (NTRS)
Renz, David D.
1992-01-01
Three separate studies have shown operational, weight, and cost advantages for commercial subsonic transport aircraft using an all-electric secondary power system. The first study in 1982 showed that all-electric secondary power systems produced the second largest benefit compared to four other technology upgrades. The second study in 1985 showed a 10 percent weight and fuel savings using an all-electric high frequency (20 kHz) secondary power system. The last study in 1991 showed a 2 percent weight savings using today's technology (400 Hz) in an all-electric secondary power system. This paper will compare the 20 kHz and 400 Hz studies, analyze the 2 to 10 percent difference in weight savings and comment on the common benefits of the all-electric secondary power system.
Comparison of all-electric secondary power systems for civil subsonic transports
NASA Technical Reports Server (NTRS)
Renz, David D.
1992-01-01
Three separate studies have shown operational, weight, and cost advantages for commercial subsonic transport aircraft using an all-electric secondary power system. The first study in 1982 showed that all-electric secondary power systems produced the second largest benefit compared to four other technology upgrades. The second study in 1985 showed a 10 percent weight and fuel savings using an all-electric high frequency (20 kHz) secondary power system. The last study in 1991 showed a 2 percent weight savings using today's technology (400 Hz) in an all-electric secondary power system. This paper will compare the 20 kHz and 400 Hz studies, analyze the 2 to 10 percent difference in weight savings and comment on the common benefits of the all-electric secondary power system.
Inverter design for high frequency power distribution
NASA Technical Reports Server (NTRS)
King, R. J.
1985-01-01
A class of simple resonantly commutated inverters are investigated for use in a high power (100 KW - 1000 KW) high frequency (10 KHz - 20 KHz) AC power distribution system. The Mapham inverter is found to provide a unique combination of large thyristor turn-off angle and good utilization factor, much better than an alternate 'current-fed' inverter. The effects of loading the Mapham inverter entirely with rectifier loads are investigated by simulation and with an experimental 3 KW 20 KHz inverter. This inverter is found to be well suited to a power system with heavy rectifier loading.
High-frequency high-voltage high-power DC-to-DC converters
NASA Technical Reports Server (NTRS)
Wilson, T. G.; Owen, H. A.; Wilson, P. M.
1982-01-01
A simple analysis of the current and voltage waveshapes associated with the power transistor and the power diode in an example current-or-voltage step-up (buck-boost) converter is presented. The purpose of the analysis is to provide an overview of the problems and design trade-offs which must be addressed as high-power high-voltage converters are operated at switching frequencies in the range of 100 kHz and beyond. Although the analysis focuses on the current-or-voltage step-up converter as the vehicle for discussion, the basic principles presented are applicable to other converter topologies as well.
High-frequency high-voltage high-power DC-to-DC converters
NASA Astrophysics Data System (ADS)
Wilson, T. G.; Owen, H. A.; Wilson, P. M.
1982-09-01
A simple analysis of the current and voltage waveshapes associated with the power transistor and the power diode in an example current-or-voltage step-up (buck-boost) converter is presented. The purpose of the analysis is to provide an overview of the problems and design trade-offs which must be addressed as high-power high-voltage converters are operated at switching frequencies in the range of 100 kHz and beyond. Although the analysis focuses on the current-or-voltage step-up converter as the vehicle for discussion, the basic principles presented are applicable to other converter topologies as well.
Oladejo, Ayobami Olayemi; Ma, Haile
2016-08-01
Sweet potato is a highly nutritious tuber crop that is rich in β-carotene. Osmotic dehydration is a pretreatment method for drying of fruit and vegetables. Recently, ultrasound technology has been applied in food processing because of its numerous advantages which include time saving, little damage to the quality of the food. Thus, there is need to investigate and optimise the process parameters [frequency (20-50 kHz), time (10-30 min) and sucrose concentration (20-60% w/v)] for ultrasound-assisted osmotic dehydration of sweet potato using response surface methodology. The optimised values obtained were frequency of 33.93 kHz, time of 30 min and sucrose concentration of 35.69% (w/v) to give predicted values of 21.62, 4.40 and 17.23% for water loss, solid gain and weight reduction, respectively. The water loss and weight reduction increased when the ultrasound frequency increased from 20 to 35 kHz and then decreased as the frequency increased from 35 to 50 kHz. The results from this work show that low ultrasound frequency favours the osmotic dehydration of sweet potato and also reduces the use of raw material (sucrose) needed for the osmotic dehydration of sweet potato. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.
Development of wide-band middle ear transmission in the Mongolian gerbil
NASA Astrophysics Data System (ADS)
Overstreet, Edward H.; Ruggero, Mario A.
2002-01-01
Stapes vibrations were measured in deeply anesthetized adult and neonatal (ages: 14 to 20 days) Mongolian gerbils. In adult gerbils, the velocity magnitude of stapes responses to tones was approximately constant over the entire frequency range of measurements, 1 to 40 kHz. Response phases referred to pressure near the tympanic membrane varied approximately linearly as a function of increasing stimulus frequency, with a slope corresponding to a group delay of 30 μs. In neonatal gerbils, the sensitivity of stapes responses to tones was lower than in adults, especially at mid-frequencies (e.g., by about 15 dB at 10-20 kHz in gerbils aged 14 days). The input impedance of the adult gerbil cochlea, calculated from stapes vibrations and published measurements of pressure in scala vestibuli near the oval window [E. Olson, J. Acoust. Soc. Am. 103, 3445-3463 (1998)], is principally dissipative at frequencies lower than 10 kHz. Conclusions: (a) middle-ear vibrations in adult gerbils do not limit the input to the cochlea up to at least 40 kHz, i.e., within 0.5 oct of the high-frequency cutoff of the behavioral audiogram; and (b) the results in both adult and neonatal gerbils are inconsistent with the hypothesis that mass reactance controls high-frequency ossicular vibrations and support the idea that the middle ear functions as a transmission line.
Storm-Time VLF Emissions Caused by The Solar Wind Disturbances: A Case Study on 8 December 2013
NASA Astrophysics Data System (ADS)
Manninen, J.; Kleimenova, N. G.; Turunen, T.; Gromova, L. I.
2017-08-01
This study is made of temporal variations of the daytime VLF emissions (1-6 kHz) occurred during the moderate magnetic storm (Kp = 6) on 8 December 2013. The storm was associated with the Coronal Mass Ejection (CME). VLF emissions were recorded in the frequency band of 0.2-39 kHz during the dark winter at Kannuslehto (KAN, L 5.5) in Northern Finland. The results were compared with simultaneous variations in the solar wind and Interplanetary Magnetic Field (IMF). It was found that intense VLF chorus started after the pressure jump in solar wind (from 7 to 12 nPa) under the positive IMF Bz. The VLF emissions occurred in two separate frequency bands. The lower frequency (below 2 kHz) band represents the intense long lasting hiss with right-hand polarization, and in the upper frequency band (above 2 kHz) the left-hand polarized hiss bursts occurred during about 1 hour. The plasmasphere was strongly compressed, and due to that KAN was mapped outside of the plasmapause. We suppose that VLF chorus exited in the magnetosphere by the cyclotron instability of the radiation belt electrons. The low frequency chorus was generated outside of the plasmapause and arrived to KAN along the direction of N-S meridian. The high-frequency band was generated inside of the plasmasphere arrived to KAN almost along the meridian.
Tsujino, Jiromaru; Hongoh, Misugi; Yoshikuni, Masafumi; Hashii, Hidekazu; Ueoka, Tetsugi
2004-04-01
The welding characteristics of 27, 40 and 67 kHz ultrasonic plastic welding systems that are driven at only the fundamental-resonance frequency vibration were compared, and also those of the welding systems that were driven at the fundamental and several higher resonance frequencies simultaneously were studied. At high frequency, welding characteristics can be improved due to the larger vibration loss of plastic materials. For welding of rather thin or small specimens, as the fundamental frequency of these welding systems is higher and the numbers of driven higher frequencies are driven simultaneously, larger welded area and weld strength were obtained.
ELF/VLF wave disturbances detected by the DEMETER satellite over the HAARP transmitter
NASA Astrophysics Data System (ADS)
Titova, Elena; Demekhov, Andrei; Parrot, Michel; Mogilevsky, Mikhail; Mochalov, Alexey; Pashin, Anatoly
We report observations of electromagnetic the ELF/VLF wave disturbances by the DEMETER satellite (670 km altitude) overflying the HAARP heating facility (62.39(°) N, 145.15(°) W, L = 4.9). The HAARP HF transmitter operated at the maximum available power of 3.6 MW, O-mode polarization, and the beam directed towards the magnetic zenith. ELF/VLF waves caused by the HAARP heating are detected by the DEMETER satellite when the HF radio wave frequency was close to the critical frequency (foF2) of the ionospheric F2 layer but below it. ELF/VLF wave disturbances observed above the HAARP transmitter were detected by electrical antennas in an area with characteristic size 10 (2) km. We analyze amplitude and polarization spectra of the ELF disturbances and compare them with the characteristics of natural ELF hiss above HAARP. The VLF wave disturbances in the topside ionosphere above the HAARP transmitter were detected in the frequency ranges 8-17 kHz and 15-18 kHz which are close to the lower hybrid resonance frequency f _LHR in the heating region and its second harmonic (2f _LHR), respectively. In the case where the HAARP HF power was modulated, the detected VLF waves were also modulated with the same frequency whereas in the ELF frequency range the modulation period of the HAARP power was not observed. Possible mechanisms of generation of the ELF/VLF disturbances produced by the HAARP transmitter in the topside ionosphere are discussed.
NASA Astrophysics Data System (ADS)
Zhang, C.; Wu, J.; Ma, Q.
2017-12-01
The environmental effect on the ionosphere caused by man-made power line emission (PLE) and power line harmonic radiation (PLHR) has become an increasing concern. Based on the observed data of 6.5 operating years of DEMETER satellite, by scanning the electric field power density time-frequency spectrograms, 133 PLHR events with central frequencies from 500 Hz to 4.5 kHz are detected in the near-Earth space above China. Among the 133 events, 129 events have PLE events at the base power system frequency (50 Hz in China). The duration time of every PLE event covers that of the corresponding PLHR event totally. As the same with PLHR, PLE is also propagating in whistler mode in the ionosphere. In two events that are detected in the conjugate region of Australian NWC VLF transmitter, radiations with line structure in the vicinity of 19.8 kHz are detected. There are 5 lines distributed from about 19.7 kHz to 19.9 kHz, which are in accordance with the frequency range of NWC transmitted signals. The frequency spacing of the 5 lines is exactly 50 Hz and the bandwidth of each line is about 10 Hz. The electric field power density of the line structure radiation is at the same level with the corresponding PLE, much higher than that of PLHR. The line structure radiations suggest possible modulation of VLF signals by PLE. At last, the variation of ionospheric parameters measured by DEMETER in relation with PLHR is analyzed statistically. As the revisiting orbits of DEMETER pass over the same area with nearly no deviation and at the same time of day, for each PLHR event, we check and average the parameters of 3 revisiting orbits before and after the event respectively. Combined with the event orbit, the variations of these parameters can be obtained. There are totally 5 tendencies: no variation, ascending, descending, crest and trough. Only a few events show no variation. Though there are differences in other 4 tendencies, none of the parameters show extremely preferences on one of the 4 tendencies. The crest and trough events are generally more than ascending and descending events, especially for ion density and O+ ion percentage. The variations of parameters show no preferences on latitude and the day of year.
Noninvasive inductive stent heating: alternative approach to prevent instent restenosis?
Floren, Michael G; Günther, Rolf W; Schmitz-Rode, Thomas
2004-05-01
To test noninvasive inductive heating of implanted vascular stents as an alternative approach for reduction or prevention of neointimal hyperplasia. Calorimetric pretests were performed to get an orientation on the different parameters of influence for inductive heating of stents. The field strength was set to a maximum of 90 kA/m within a frequency range from 80 kHz to 320 kHz. The electromagnetic field was emitted by a custom-made water-cooled copper winding antenna. A flow model for stent heating was set up to assess the increase in temperature of an expanded 316L stainless steel stent with typical coronary stent dimensions of 3.5 mm diameter and 14.5 mm in length, and in a second setup with 4.5 mm diameter and 13 mm in length, respectively. The stent was located in a bioartificial artery, simulated by a fibrinogen matrix with a defined number of vital cells. The system was exposed to a pulsating perfusion and to an electromagnetic field of 200 kHz over a period of 20 minutes and in a second setup to an electromagnetic field of 300 kHz and increasing intensity up to maximum power-output. Afterward, the artificial vessel was sliced and examined by fluorescence microscopy to evaluate the number and location of damaged cells. The calorimetric tests show an exponential correlation of energy uptake in the stent with an increase in frequency and a constant generator output. At a frequency of 80 kHz, the power uptake accounts for 0.1 W (250 kHz 1.0 W; 320 kHz 1.9 W, respectively). The flow tests confirmed feasibility to elevate the stent temperature from 37 degrees C body temperature to 44 degrees C at 200 kHz within 55 seconds. The temperature increase of the fluid passing the heated vessel region was only marginal (maximum of 0.5 degrees C). Cell necrosis after 20 minutes of treatment was not observed. In a second set-up with 4.5 mm stent diameter, a frequency of 300 kHz and with maximum power output, the stent temperature was increased to 80 degrees C and there was extensive necrosis area around the stent. Treatment time and stent temperature were optimized in further tests. Selective noninvasive energy transfer to coronary stainless steel stents by inductive heating is possible within a wide range of power. By thermal conduction, vital cells close to the stent struts can be affected. The frequency of 200 kHz turned out to be favorable. There is still room for further optimization of energy dosage with regard to material and stent design, to induce controlled cell death. The method has potential to serve as an alternative approach for prevention of instent restenosis.
Calibration of laser vibrometers at frequencies up to 100 kHz and higher
NASA Astrophysics Data System (ADS)
Silva Pineda, Guillermo; von Martens, Hans-Jürgen; Rojas, Sergio; Ruiz, Arturo; Muñiz, Lorenzo
2008-06-01
Manufacturers and users of laser vibrometers exploit the wide frequency and intensity ranges of laser techniques, ranging over many decades (e.g., from 0.1 Hz to 100 MHz). Traceability to primary measurement standards is demanded over the specified measurement ranges of any measurement instrumentation. As the primary documentary standard ISO 16063-11 for the calibration of vibration transducers is restricted to 10 kHz, a new international standard for the calibration of laser vibrometers, ISO 16063-41, is under development. The current stage of the 2nd Committee Draft (CD) of the ISO standard specifies calibration methods for frequencies from 0.4 Hz to 50 kHz which does not meet the demand for providing traceability at higher frequencies. New investigations will be presented which demonstrate the applicability of the laser interferometer methods specified in ISO 16063-11 and in the 2nd CD also at higher frequencies of 100 kHz and beyond. The three standard methods were simultaneously used for vibration displacement and acceleration measurements up to 100 kHz, and a fourth high-accuracy method has been developed and used. Their results in displacement and acceleration measurements deviated by less than 1 % from each other at vibration displacement amplitudes in the order of 100 nm. In addition to the three interferometer methods specified in ISO 16063-11 and 16063-15, and in the 2nd Committee Draft of 16063-41 as well, measurement results will be presented. Examples of laser vibrometer calibrations will bedemonstrated. Further investigations are aimed
Brain stem auditory potentials evoked by clicks in the presence of high-pass filtered noise in dogs.
Poncelet, L; Deltenre, P; Coppens, A; Michaux, C; Coussart, E
2006-04-01
This study evaluates the effects of a high-frequency hearing loss simulated by the high-pass-noise masking method, on the click-evoked brain stem-evoked potentials (BAEP) characteristics in dogs. BAEP were obtained in response to rarefaction and condensation click stimuli from 60 dB normal hearing level (NHL, corresponding to 89 dB sound pressure level) to wave V threshold, using steps of 5 dB in eleven 58 to 80-day-old Beagle puppies. Responses were added, providing an equivalent to alternate polarity clicks, and subtracted, providing the rarefaction-condensation potential (RCDP). The procedure was repeated while constant level, high-pass filtered (HPF) noise was superposed to the click. Cut-off frequencies of the successively used filters were 8, 4, 2 and 1 kHz. For each condition, wave V and RCDP thresholds, and slope of the wave V latency-intensity curve (LIC) were collected. The intensity range at which RCDP could not be recorded (pre-RCDP range) was calculated. Compared with the no noise condition, the pre-RCDP range significantly diminished and the wave V threshold significantly increased when the superposed HPF noise reached the 4 kHz area. Wave V LIC slope became significantly steeper with the 2 kHz HPF noise. In this non-invasive model of high-frequency hearing loss, impaired hearing of frequencies from 8 kHz and above escaped detection through click BAEP study in dogs. Frequencies above 13 kHz were however not specifically addressed in this study.
NASA Astrophysics Data System (ADS)
Li, Guoxing; Xie, Wenqiang; Yang, Xining; Zhang, Ziqiu; Zhang, Hongda; Zhang, Liang
2018-02-01
A two-end-pumped a-cut Tm(0.5%), Ho(0.5%):YAP laser output at 2119nm is reported under cryogenic temperature. The maximum output power reached to 7.76W with the incident pump power of 24.2W in CW mode. With the acousto-optically Q-switch, an average power of 7.3W can be obtained, when the pulse repetition frequency was 7.5 kHz. The corresponding optical-to-optical conversion efficiency was 30.2% and the slope efficiency was 31.4%. Then, the laser output characteristics in the repetition frequency of 7.5 kHz and 10kHz were researched. The output power, the optical-to-optical conversion efficiency and slope efficiency were increased with the increase of the repetition frequency. In the same repetition frequency, the pulse duration was decreasing with the growth of the incident pump power.
Effect of ultrasonic cavitation on measurement of sound pressure using hydrophone
NASA Astrophysics Data System (ADS)
Thanh Nguyen, Tam; Asakura, Yoshiyuki; Okada, Nagaya; Koda, Shinobu; Yasuda, Keiji
2017-07-01
Effect of ultrasonic cavitation on sound pressure at the fundamental, second harmonic, and first ultraharmonic frequencies was investigated from low to high ultrasonic intensities. The driving frequencies were 22, 304, and 488 kHz. Sound pressure was measured using a needle-type hydrophone and ultrasonic cavitation was estimated from the broadband integrated pressure (BIP). With increasing square root of electric power applied to a transducer, the sound pressure at the fundamental frequency linearly increased initially, dropped at approximately the electric power of cavitation inception, and afterward increased again. The sound pressure at the second harmonic frequency was detected just below the electric power of cavitation inception. The first ultraharmonic component appeared at around the electric power of cavitation inception at 304 and 488 kHz. However, at 22 kHz, the first ultraharmonic component appeared at a higher electric power than that of cavitation inception.
Development of a long-gauge vibration sensor
NASA Astrophysics Data System (ADS)
Kung, Peter; Comanici, Maria I.
2014-06-01
Recently, we found that by terminating a long length of fiber of up to 2 km with an in-fiber cavity structure, the entire structure can detect vibrations over a frequency range from 5 Hz to 100 Hz. We want to determine whether the structure (including packaging) can be optimized to detect vibrations at even higher frequencies. The structure can be used as a distributed vibration sensor mounted on large motors and other rotating machines to capture the entire frequency spectrum of the associated vibration signals, and therefore, replace the many accelerometers, which add to the maintenance cost. Similarly, it will help detect in-slot vibrations which cause intermittent contact leading to sparking under high voltages inside air-cooled generators. However, that will require the sensor to detect frequencies associated with vibration sparking, ranging from 6 kHz to 15 kHz. Then, at even higher frequencies, the structure can be useful to detect acoustic vibrations (30 kHz to 150 kHz) associated with partial discharge (PD) in generators and transformers. Detecting lower frequencies in the range 2 Hz to 200 Hz makes the sensor suitable for seismic studies and falls well into the vibrations associated with rotating machines. Another application of interest is corrosion detection in large re-enforced concrete structures by inserting the sensor along a long hole drilled around structures showing signs of corrosion. The frequency response for the proposed long-gauge vibration sensor depends on packaging.
Rooze, Joost; Rebrov, Evgeny V; Schouten, Jaap C; Keurentjes, Jos T F
2011-01-01
The sonochemical oxidation efficiency (η(ox)) of a commercial titanium alloy ultrasound horn has been measured using potassium iodide as a dosimeter at its main resonance frequency (20 kHz) and two higher resonance frequencies (41 and 62 kHz). Narrow power and frequency ranges have been chosen to minimise secondary effects such as changing bubble stability, and time available for radical diffusion from the bubble to the liquid. The oxidation efficiency, η(ox), is proportional to the frequency and to the power transmitted to the liquid (275 mL) in the applied power range (1-6 W) under argon. Luminol radical visualisation measurements show that the radical generation rate increases and a redistribution of radical producing zones is achieved at increasing frequency. Argon, helium, air, nitrogen, oxygen, and carbon dioxide have been used as saturation gases in potassium iodide oxidation experiments. The highest η(ox) has been observed at 5 W under air at 62 kHz. The presence of carbon dioxide in air gives enhanced nucleation at 41 and 62 kHz and has a strong influence on η(ox). This is supported by the luminol images, the measured dependence of η(ox) on input power, and bubble images recorded under carbon dioxide. The results give insight into the interplay between saturation gas and frequency, nucleation, and their effect on η(ox). Copyright © 2010 Elsevier B.V. All rights reserved.
Acoustic Environment of Admiralty Inlet: Broadband Noise Measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Jinshan; Deng, Zhiqun; Martinez, Jayson J.
2011-09-30
Admiralty Inlet has been selected as a potential tidal energy site. It is located near shipping lanes, is a highly variable acoustic environment, and is frequented by the highly endangered southern resident killer whale (SRKW). Resolving environmental impacts is the first step to receiving approval to deploy tidal turbines at Admiralty Inlet. Of particular concern is the potential for blade strike or other negative interactions between the SRKW and the tidal turbine. A variety of technologies including passive and active monitoring systems are being considered as potential tools to determine the presence of SRKW in the vicinity of the turbines.more » Broadband noise level measurements are critical for the determination of design and operation specifications of all marine and hydrokinetic energy capture technologies. Acoustic environment data at the proposed site was acquired at different depths using a cabled vertical line array (VLA) with four calibrated hydrophones. The sound pressure level (SPL) power spectrum density was estimated based on the fast Fourier transform. This study describes the first broadband SPL measurements for this site at different depths with frequency ranging from 10 kHz to 480 kHz in combination with other information. To understand the SPL caused by this bedload transport, three different pressure sensors with temperature and conductivity were also assembled on the VLA to measure the conditions at the hydrophone deployment depth. The broadband SPL levels at frequency ranges of 3 kHz to 7 kHz as a function of depth were estimated. Only the hydrophone at an average depth of 40 m showed the strong dependence of SPL with distance from the bottom, which was possibly caused by the cobbles shifting on the seabed. Automatic Identification System data were also studied to understand the SPL measurements.« less
The JET diagnostic fast central acquisition and trigger system (abstract)
NASA Astrophysics Data System (ADS)
Edwards, A. W.; Blackler, K.
1995-01-01
Most plasma physics diagnostics sample at a fixed frequency that is normally matched to available memory limits. This technique is not appropriate for long pulse machines such as JET where sampling frequencies of hundreds of kHz are required to diagnose very fast events. As a result of work using real-time event selection within the previous JET soft x-ray diagnostic, a single data acquisition and event triggering system for all suitable fast diagnostics, the fast central acquisition and trigger system (Fast CATS), has been developed for JET. The front-end analog-to-digital conversion (ADC) part samples all channels at 250 kHz, with a 100 kHz pass band and a stop band of 125 kHz. The back-end data collection system is based around Texas Instruments TMS320C40 microprocessors. Within this system, two levels of trigger algorithms are able to evaluate data. The first level typically analyzes data on a per diagnostic and individual channel basis. The second level looks at the data from one or more diagnostics in a window around the time of interest flagged by the first level system. Selection criteria defined by the diagnosticians are then imposed on the results from the second level to decide whether that data should be kept. The use of such a system involving intelligent real time trigger algorithms and fast data analysis will improve both the quantity and quality of JET diagnostic data, while providing valuable input to the design of data acquisition systems for very long pulse machines such as ITER. This paper will give an overview of the various elements of this new system. In addition, first results from this system following the restart of JET operation will be presented.
Regenerator Operation at Very High Frequencies for Microcryocoolers
NASA Astrophysics Data System (ADS)
Radebaugh, Ray; O'Gallagher, Agnes
2006-04-01
The size of Stirling and Stirling-type pulse tube cryocoolers is dominated by the size of the pressure oscillator. Such cryocoolers typically operate at frequencies up to about 60 Hz for cold-end temperatures above about 60 K. Higher operating frequencies would allow the size and mass of the pressure oscillator to be reduced for a given power input. However, simply increasing the operating frequency leads to large losses in the regenerator. The simple analytical equations derived here show how the right combination of frequency and pressure, along with optimized regenerator geometry, can lead to successful regenerator operation at frequencies up to 1 kHz. Efficient regenerator operation at such high frequencies is possible only with pressures of about 5 to 8 MPa and with very small hydraulic diameters and lengths. Other geometrical parameters must also be optimized for such conditions. The analytical equations are used to provide guidance to the right combination of parameters. We give example numerical calculations with REGEN3.2 in the paper for 60 Hz, 400 Hz, and 1000 Hz operation of optimized screen regenerators and show that the coefficient of performance at 400 Hz and 1000 Hz is about 78 % and 68 %, respectively, of that for 60 Hz when an average pressure of 7 MPa is used with the higher frequency, compared with 2.5 MPa for 60 Hz operation. The 1000 Hz coefficient of performance for parallel tubes is about the same as that of the screen geometry at 60 Hz. The compressor and cold-end swept volumes are reduced by a factor of 47 at 1000 Hz, compared with the 60 Hz case for the same input acoustic power, which can enable the development of microcryocoolers for MEMS applications.
47 CFR 80.1127 - On-scene communications.
Code of Federal Regulations, 2014 CFR
2014-10-01
... ITU-R Recommendation M.625-3, with Annex, as specified in § 80.1101. (c) The preferred frequencies in radiotelephony for on-scene communications are 156.8 MHz and 2182 kHz. The frequency 2174.5 kHz may also be used... error correcting mode in accordance with ITU-R M.625-3 (incorporated by reference, see § 80.7), as...
Kilometric Continuum Radiation
NASA Technical Reports Server (NTRS)
Green, James L.; Boardsen, Scott
2006-01-01
Kilometric continuum (KC) is the high frequency component (approximately 100 kHz to approximately 800 kHz) of nonthermal continuum (NTC). Unlike the lower frequency portion of NTC (approximately 5 kHz to approximately 100 kHz) whose source is around the dawn sector, the source of KC occurs at all magnetic local times. The latitudinal beaming of KC as observed by GEOTAIL is, for most events, restricted to plus or minus 15 degrees magnetic latitude. KC has been observed during periods of both low and strong geomagnetic activity, with no significant correlation of wave intensity with K(sub p), index. However statistically the maximum observed frequency of KC emission tends to increase with K(sub p) index, the effect is more pronounced around solar maximum, but is also detected near solar minimum. There is strong evidence that the source region of KC is from the equatorial plasmapause during periods when a portion of the plasmapause moves significantly inwards from its nominal position. Case studies have shown that KC emissions are nearly always associated with plasmaspheric notches, shoulders, and tails. There is a recent focus on trying to understand the banded frequency structure of this emission and its relationship to plasmaspheric density ducts and irregularities in the source region.
Shikha Ojha, K; Granato, Daniel; Rajuria, Gaurav; Barba, Francisco J; Kerry, Joseph P; Tiwari, Brijesh K
2018-01-15
The effects of ultrasound (US) frequency, addition of Lactobacillus sakei culture and drying time on key nutritional (protein, amino acids, and organic acids) and physicochemical properties (texture and colour) of cultured and uncultured beef jerky were evaluated. Cultured and uncultured jerky samples were subjected to US frequencies of 25kHz, 33kHz and 45kHz for 30min prior to marination and drying. Principal component analysis demonstrated a significant effect of beef jerky processing conditions on physicochemical properties. Taurine content of jerky samples was found to increase with an increase in ultrasonic frequencies for cultured samples. No significant changes in colour values were observed for ultrasound pre-treated and control samples. Interactive effects of culture treatment, drying and ultrasonic frequency were observed. This study demonstrates that the nutritional profile of beef jerky can be improved through the incorporation of L. sakei. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Rat Acoustic Tolerance Test 1994-1995: 8 kHz, 16 kHz, 32 kHz Experiments
NASA Technical Reports Server (NTRS)
Mele, Gary D.; Holley, Daniel C.; Naidu, Sujata
1996-01-01
Adult male Sprague-Dawley rats were exposed to chronic applied sound (74 to 79 dB, SPL) with octave band center frequencies of either 8, 16 or 32 kHz for up to 60 days. Control cages had ambient sound levels of about 62 dB (SPL). Groups of rats (test vs. control; N=9 per group) were euthanized after 0. 5. 14, 30, and 60 days. On each euthanasia day, objective evaluation of their physiology and behavior was performed using a Stress Assessment Battery (SAB) of measures. In addition, rat hearing was assessed using the brain stem auditory evoked potential (BAER) method after 60 days of exposure. No statistically significant differences in mean daily food use could be attributed to the presence of the applied test sound. Test rats used 5% more water than control rats. In the 8 kHz and 32 kHz tests this amount was statistically significant(P less than .05). This is a minor difference of questionable physiological significance. However, it may be an indication of a small reaction to the constant applied sound. Across all test frequencies, day 5 test rats had 6% larger spleens than control rats. No other body or organ weight differences were found to be statistically significant with respect to the application of sound. This spleen effect may be a transient adaptive process related to adaptation to the constant applied noise. No significant test effect on differential white blood cell counts could be demonstrated. One group demonstrated a low eosinophil count (16 kHz experiment, day 14 test group). However this was highly suspect. Across all test frequencies studied, day 5 test rats had 17% fewer total leukocytes than day 5 control rats. Sound exposed test rats exhibited 44% lower plasma corticosterone concentrations than did control rats. Note that the plasma corticosterone concentration was lower in the sound exposed test animals than the control animals in every instance (frequency exposure and number of days exposed).
Phase noise suppression through parametric filtering
NASA Astrophysics Data System (ADS)
Cassella, Cristian; Strachan, Scott; Shaw, Steven W.; Piazza, Gianluca
2017-02-01
In this work, we introduce and experimentally demonstrate a parametric phase noise suppression technique, which we call "parametric phase noise filtering." This technique is based on the use of a solid-state parametric amplifier operating in its instability region and included in a non-autonomous feedback loop connected at the output of a noisy oscillator. We demonstrate that such a system behaves as a parametrically driven Duffing resonator and can operate at special points where it becomes largely immune to the phase fluctuations that affect the oscillator output signal. A prototype of a parametric phase noise filter (PFIL) was designed and fabricated to operate in the very-high-frequency range. The PFIL prototype allowed us to significantly reduce the phase noise at the output of a commercial signal generator operating around 220 MHz. Noise reduction of 16 dB (40×) and 13 dB (20×) were obtained, respectively, at 1 and 10 kHz offsets from the carrier frequency. The demonstration of this phase noise suppression technique opens up scenarios in the development of passive and low-cost phase noise cancellation circuits for any application demanding high quality frequency generation.
NASA Astrophysics Data System (ADS)
Fullekrug, M.; Liu, Z.; Koh, K.; Mezentsev, A.; Pedeboy, S.; Soula, S.; Sugier, J.; Enno, S. E.; Rycroft, M. J.
2016-12-01
Transient Luminous Events (TLEs) can generate electromagnetic radiation at frequencies 100 kHz (Qin et al., 2012, Fullekrug et al., 2013) and <1 kHz (Pasko et al., GRL, 1998, Cummer et al., GRL, 1998)as a result of the splitting and exponential growth of streamer discharges (Pasko, JGR, 2010, McHarg, JGR, 2010). The electromagnetic radiation results from the coherent superposition of the very weak signalsfrom thousands of small scale streamer discharges at 40 km height for frequencies 100 kHz and at 80 km height for frequencies <1 kHz. It seems therefore plausible that TLEs can also generate electromagnetic waves at intermediate heights, e.g. 60 km with frequencies between 1-100 kHz, e.g., 10 kHz. However, this frequency range is dominated by the powerful electromagnetic radiation from return strokes and it is hence commonly thought that this radiation can not easily be detectedwith single radio receivers. This study proposes to search for electromagnetic radiation from TLEsabove thunderclouds by use of a mini array that has the ability to determine the elevation angle toward the radiation source. Mini arrays with small apertures are used for infrasonic and seismic studies to determine source mechanisms and properties of the medium through which the waves propagate. For the detection of electromagneticradiation, the array processing is adapted for the fast propagationat the speed of light. Here we report for the first time the detection and mapping of distant lightning strokes in the sky with a mini array located near Bath in the UK. The array has a baseline to wavelength ratio 4.2 10^{-2} to record electromagnetic waves from 2-18 kHz. It is found that the mini array detects 69 lightning strokes per second from cloud-to-ground and in-cloud discharges, even though the parent thunderstorms are 900-1,100 km away and a rigorous selection criterion based on the spatial coherency of the electromagnetic source field across the array is used. About 14% of the lightning strokes appear at larger elevation angles in the sky than the remaining 86% of lightning strokes as the result of birefringent subionospheric wave propagation attributed to ordinary and extra-ordinary waves. These results imply that mini arrays can be used to detect electromagnetic radiation from TLEs above thunderclouds in different frequency ranges.
Feeney, M. Patrick; Keefe, Douglas H.; Hunter, Lisa L.; Fitzpatrick, Denis F.; Garinis, Angela C.; Putterman, Daniel B.; McMillan, Garnett P.
2016-01-01
Objectives Wideband acoustic immittance (WAI) measures such as pressure reflectance, parameterized by absorbance and group delay, equivalent admittance at the tympanic membrane (TM), and acoustic stapedius reflex threshold (ASRT) describe middle-ear function across a wide frequency range, compared to traditional tests employing a single frequency. The objective of this study was to obtain normative data using these tests for a group of normal hearing adults and investigate test-retest reliability using a longitudinal design. Design A longitudinal prospective design was used to obtain normative test and retest data on clinical and WAI measures. Subjects were 13 males and 20 females (mean age = 25 y). Inclusion criteria included normal audiometry and clinical immittance. Subjects were tested on two separate visits approximately one month apart. Reflectance and equivalent admittance at the TM were measured from 0.25 to 8.0 kHz under three conditions: at ambient pressure in the ear canal and with pressure sweeps from positive to negative pressure (downswept) and negative to positive pressure (upswept). Equivalent admittance at the TM was calculated using admittance measurements at the probe tip which were adjusted using a model of sound transmission in the ear canal and acoustic estimates of ear-canal area and length. Wideband ASRTs were measured at tympanometric peak pressure (TPP) derived from the average TPP of downswept and upswept tympanograms. Descriptive statistics were obtained for all WAI responses, and wideband and clinical ASRTs were compared. Results Mean absorbance at ambient pressure and TPP demonstrated a broad band-pass pattern typical of previous studies. Test-retest differences were lower for absorbance at TPP for the downswept method compared to ambient pressure at frequencies between 1.0 and 1.26 kHz. Mean tympanometric peak-to-tail differences for absorbance were greatest around 1.0 to 2.0 kHz and similar for positive and negative tails. Mean group delay at ambient pressure and at TPP were greatest between 0.32 and 0.6 kHz at 200 to 300 μs, reduced at frequencies between 0.8 and 1.5 kHz, and increased above 1.5 kHz to around 150 μs. Mean equivalent admittance at the TM had a lower level for the ambient method than at TPP for both sweep directions below 1.2 kHz, but the difference between methods was only statistically significant for the comparison between the ambient method and TPP for the upswept tympanogram. Mean equivalent admittance phase was positive at all frequencies. Test-retest reliability of the equivalent admittance level ranged from 1 to 3 dB at frequencies below 1.0 kHz, but increased to 8 to 9 dB at higher frequencies. The mean wideband ASRT for an ipsilateral broadband noise activator was 12 dB lower than the clinical ASRT, but had poorer reliability. Conclusions Normative data for the WAI test battery revealed minor differences for results at ambient pressure compared to tympanometric methods at TPP for reflectance, group delay, and equivalent admittance level at the TM for subjects with middle-ear pressure within ±100 daPa. Test-retest reliability was better for absorbance at TPP for the downswept tympanogram compared to ambient pressure at frequencies around 1.0 kHz. Large peak-to-tail differences in absorbance combined with good reliability at frequencies between about 0.7 and 3.0 kHz suggest that this may be a sensitive frequency range for interpreting absorbance at TPP. The mean wideband ipsilateral ASRT was lower than the clinical ASRT, consistent with previous studies. Results are promising for the use of a wideband test battery to evaluate middle-ear function. PMID:28045835
VizieR Online Data Catalog: HCOO13CH3 rotational spectrum
NASA Astrophysics Data System (ADS)
Haykal, I.; Carvajal, M.; Tercero, B.; Kleiner, I.; Lopez, A.; Cernicharo, J.; Motiyenko, R. A.; Huet, T. R.; Guillemin, J. C.; Margules, L.
2014-08-01
The details about synthesis and identification by NMR spectroscopy were described in Carvajal et al. (2009, Cat. J/A+A/500/1109). The millimeter- and submillimeter-wave spectra were recorded using the Lille spectrometer that is based on solid-state sources. The sample pressure was in the range 20-30x10-6 bars. Spectra were recorded at room temperature (T=294K) in the 150-210, 225-315, 400-500, 500-630, and 780-940GHz regions with frequency steps of 30, 36, 48, 54, and 76kHz and an acquisition time of 35ms per point. The absolute accuracy of the line-centre frequency is estimated to be better than 30kHz (50kHz above 700GHz) for isolated lines and can be as low as 100kHz (150kHz above 700GHz) for blended or very weak lines. See section 2.2. The IRAM spectra will be published on the IRAM website: http://www.iram-institute.org/ (1 data file).
Antonioli, Cleonice Aparecida Silva; Momensohn-Santos, Teresa Maria; Benaglia, Tatiana Aparecida Silva
2016-07-01
The literature reports on high-frequency audiometry as one of the exams used on hearing monitoring of individuals exposed to high sound pressure in their work environment, due to the method́s greater sensitivity in early identification of hearing loss caused by noise. The frequencies that compose the exam are generally between 9 KHz and 20KHz, depending on the equipment. This study aims to perform a retrospective and secondary systematic revision of publications on high-frequency audiometry on hearing monitoring of individuals exposed to occupational noise. This systematic revision followed the methodology proposed in the Cochrane Handbook, focusing on the question: "Is High-frequency Audiometry more sensitive than Conventional Audiometry in the screening of early hearing loss individuals exposed to occupational noise?" The search was based on PubMed data, Base, Web of Science (Capes), Biblioteca Virtual em Saúde (BVS), and in the references cited in identified and selected articles. The search resulted in 6059 articles in total. Of these, only six studies were compatible with the criteria proposed in this study. The performed meta-analysis does not definitively answer the study's proposed question. It indicates that the 16 KHz high frequency audiometry (HFA) frequency is sensitive in early identification of hearing loss in the control group (medium difference (MD = 8.33)), as well as the 4 KHz frequency (CA), this one being a little less expressive (MD = 5.72). Thus, others studies are necessary to confirm the HFA importance for the early screening of hearing loss on individuals exposed to noise at the workplace.
Tunable single frequency fiber laser based on FP-LD injection locking.
Zhang, Aiqin; Feng, Xinhuan; Wan, Minggui; Li, Zhaohui; Guan, Bai-ou
2013-05-20
We propose and demonstrate a tunable single frequency fiber laser based on Fabry Pérot laser diode (FP-LD) injection locking. The single frequency operation principle is based on the fact that the output from a FP-LD injection locked by a multi-longitudinal-mode (MLM) light can have fewer longitudinal-modes number and narrower linewidth. By inserting a FP-LD in a fiber ring laser cavity, single frequency operation can be possibly achieved when stable laser oscillation established after many roundtrips through the FP-LD. Wavelength switchable single frequency lasing can be achieved by adjusting the tunable optical filter (TOF) in the cavity to coincide with different mode of the FP-LD. By adjustment of the drive current of the FP-LD, the lasing modes would shift and wavelength tunable operation can be obtained. In experiment, a wavelength tunable range of 32.4 nm has been obtained by adjustment of the drive current of the FP-LD and a tunable filter in the ring cavity. Each wavelength has a side-mode suppression ratio (SMSR) of at least 41 dB and a linewidth of about 13 kHz.
The highest-frequency kHz QPOs in neutron star low mass X-ray binaries
NASA Astrophysics Data System (ADS)
van Doesburgh, Marieke; van der Klis, Michiel; Morsink, Sharon M.
2018-05-01
We investigate the detections with RXTE of the highest-frequency kHz QPOs previously reported in six neutron star (NS) low mass X-ray binaries. We find that the highest-frequency kHz QPO detected in 4U 0614+09 has a 1267 Hz 3σ confidence lower limit on its centroid frequency. This is the highest such limit reported to date, and of direct physical interest as it can be used to constrain QPO models and the supranuclear density equation of state (EoS). We compare our measured frequencies to maximum orbital frequencies predicted in full GR using models of rotating neutron stars with a number of different modern EoS and show that these can accommodate the observed QPO frequencies. Orbital motion constrained by NS and ISCO radii is therefore a viable explanation of these QPOs. In the most constraining case of 4U 0614+09 we find the NS mass must be M<2.1 M⊙. From our measured QPO frequencies we can constrain the NS radii for five of the six sources we studied to narrow ranges (±0.1-0.7 km) different for each source and each EoS.
Broadly tunable ultrafast pump-probe system operating at multi-kHz repetition rate
NASA Astrophysics Data System (ADS)
Grupp, Alexander; Budweg, Arne; Fischer, Marco P.; Allerbeck, Jonas; Soavi, Giancarlo; Leitenstorfer, Alfred; Brida, Daniele
2018-01-01
Femtosecond systems based on ytterbium as active medium are ideal for driving ultrafast optical parametric amplifiers in a broad frequency range. The excellent stability of the source and the repetition rate tunable to up to hundreds of kHz allow for the implementation of an advanced two-color pump probe setup with the capability to achieve excellent signal-to-noise performances with sub-10 fs temporal resolution.
Another Nulling Hall-Effect Current-Measuring Circuit
NASA Technical Reports Server (NTRS)
Thibodeau, Phillip E.; Sullender, Craig C.
1993-01-01
Lightweight, low-power circuit provides noncontact measurement of alternating or direct current of many ampheres in main conductor. Advantages of circuit over other nulling Hall-effect current-measuring circuits is stability and accuracy increased by putting both analog-to-digital and digital-to-analog converters in nulling feedback loop. Converters and rest of circuit designed for operation at sampling rate of 100 kHz, but rate changed to alter time or frequency response of circuit.
200 kHz Commercial Sonar Systems Generate Lower Frequency Side Lobes Audible to Some Marine Mammals
Deng, Z. Daniel; Southall, Brandon L.; Carlson, Thomas J.; Xu, Jinshan; Martinez, Jayson J.; Weiland, Mark A.; Ingraham, John M.
2014-01-01
The spectral properties of pulses transmitted by three commercially available 200 kHz echo sounders were measured to assess the possibility that marine mammals might hear sound energy below the center (carrier) frequency that may be generated by transmitting short rectangular pulses. All three sounders were found to generate sound at frequencies below the center frequency and within the hearing range of some marine mammals, e.g. killer whales, false killer whales, beluga whales, Atlantic bottlenose dolphins, harbor porpoises, and others. The frequencies of these sub-harmonic sounds ranged from 90 to 130 kHz. These sounds were likely detectable by the animals over distances up to several hundred meters but were well below potentially harmful levels. The sounds generated by the sounders could potentially affect the behavior of marine mammals within fairly close proximity to the sources and therefore the exclusion of echo sounders from environmental impact analysis based solely on the center frequency output in relation to the range of marine mammal hearing should be reconsidered. PMID:24736608
NASA Astrophysics Data System (ADS)
Budovsky, Ilya
2010-01-01
The APMP international comparison of ac-dc transfer standards at the lowest attainable level of uncertainty, APMP.EM-K6a, started in 2000 and concluded in 2003. This comparison has offered the same range and frequencies as the key comparison CCEM-K6a with the view of providing the National Metrology Institutes (NMIs) of the APMP member economies with an opportunity to link the values of their standards for ac-dc transfer difference to the international reference values. The ac-dc difference of the travelling standard was measured with 3 V applied at standard frequencies of 1 kHz, 20 kHz, 100 kHz and 1 MHz, and optional frequencies of 50 kHz and 500 kHz. The travelling standard has not been damaged and has shown excellent stability. The results submitted by the overwhelming majority of the participants lie well within the reported uncertainty. At the standard frequencies the results have been linked to those of the CCEM-K6a key comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Unknown radio emission at about 3 MHz recorded in Norway
NASA Astrophysics Data System (ADS)
Farges, T.; Blanc, E.; Strand, E.
2012-04-01
A wideband electric field antenna has been installed in Norway (at Hessdalen, 62°41' North and 11°12' East). A signal of 50 ms is automatically recorded every 5 s in order to monitor the spectral variations from 1 kHz to 5 MHz. Signals have been acquired during more than one year from September 2010 to December 2011. The measured electromagnetic spectrum is very similar to other spectra commonly measured in other places in the World. It shows emissions in numerous bands at fixed frequencies corresponding to radio transmissions in VLF, LF, MF and HF bands. However, one emission is quite different and arouses our curiosity. We find a quasi-continuous radio emission at a frequency varying from 2.7 to more than 3.4 MHz with a mean value of 3.0 MHz. The bandwidth is quite large (about 40 kHz) while it is about 9 kHz for all the other radio emissions at frequencies higher than 100 kHz. During the night, the frequency is relatively stable at about 3.1 MHz while during day-time a frequency shift of 200-300 kHz is often observed. These variations can be quick (few tens of minutes) or slow (several hours). Moreover, the emission disappears during day-time, the disappearance duration depending on the daylight duration. From November to the end of March, there is almost no disappearance while in April disappearances are more frequent and longer. From May to July, the emission disappears systematically during day-time from 6:00 UT to 20:00 UT. At the sunrise time the emission frequency suddenly decreases and systematically disappears when it reaches a threshold value (from 2.7 to 2.85 MHz). The emission (frequency and duration) is not influenced by the magnetic storms. We will show in the paper statistical results and some hypothesis on the mechanism which can produce this radio emission.
Acoustic levitator for structure measurements on low temperature liquid droplets.
Weber, J K R; Rey, C A; Neuefeind, J; Benmore, C J
2009-08-01
A single-axis acoustic levitator was constructed and used to levitate liquid and solid drops of 1-3 mm in diameter at temperatures in the range -40 to +40 degrees C. The levitator comprised (i) two acoustic transducers mounted on a rigid vertical support that was bolted to an optical breadboard, (ii) an acoustic power supply that controlled acoustic intensity, relative phase of the drive to the transducers, and could modulate the acoustic forces at frequencies up to 1 kHz, (iii) a video camera, and (iv) a system for providing a stream of controlled temperature gas flow over the sample. The acoustic transducers were operated at their resonant frequency of approximately 22 kHz and could produce sound pressure levels of up to 160 dB. The force applied by the acoustic field could be modulated to excite oscillations in the sample. Sample temperature was controlled using a modified Cryostream Plus and measured using thermocouples and an infrared thermal imager. The levitator was installed at x-ray beamline 11 ID-C at the Advanced Photon Source and used to investigate the structure of supercooled liquids.
Broadband turbulent spectra in gamma-ray burst light curves
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Putten, Maurice H. P. M.; Guidorzi, Cristiano; Frontera, Filippo, E-mail: mvp@sejong.ac.kr
2014-05-10
Broadband power density spectra offer a window to understanding turbulent behavior in the emission mechanism and, at the highest frequencies, in the putative inner engines powering long gamma-ray bursts (GRBs). We describe a chirp search method alongside Fourier analysis for signal detection in the Poisson noise-dominated, 2 kHz sampled, BeppoSAX light curves. An efficient numerical implementation is described in O(Nnlog n) operations, where N is the number of chirp templates and n is the length of the light-curve time series, suited for embarrassingly parallel processing. For the detection of individual chirps over a 1 s duration, the method is onemore » order of magnitude more sensitive in signal-to-noise ratio than Fourier analysis. The Fourier-chirp spectra of GRB 010408 and GRB 970816 show a continuation of the spectral slope with up to 1 kHz of turbulence identified in low-frequency Fourier analysis. The same continuation is observed in an average spectrum of 42 bright, long GRBs. An outlook on a similar analysis of upcoming gravitational wave data is included.« less
Continued Development and Validation of Methods for Spheromak Simulation
NASA Astrophysics Data System (ADS)
Benedett, Thomas
2015-11-01
The HIT-SI experiment has demonstrated stable sustainment of spheromaks; determining how the underlying physics extrapolate to larger, higher-temperature regimes is of prime importance in determining the viability of the inductively-driven spheromak. It is thus prudent to develop and validate a computational model that can be used to study current results and provide an intermediate step between theory and future experiments. A zero-beta Hall-MHD model has shown good agreement with experimental data at 14.5 kHz injector operation. Experimental observations at higher frequency, where the best performance is achieved, indicate pressure effects are important and likely required to attain quantitative agreement with simulations. Efforts to extend the existing validation to high frequency (~ 36-68 kHz) using an extended MHD model implemented in the PSI-TET arbitrary-geometry 3D MHD code will be presented. Results from verification of the PSI-TET extended MHD model using the GEM magnetic reconnection challenge will also be presented along with investigation of injector configurations for future SIHI experiments using Taylor state equilibrium calculations. Work supported by DoE.
The Galileo plasma wave investigation
NASA Technical Reports Server (NTRS)
Gurnett, D. A.; Kurth, W. S.; Shaw, R. R.; Roux, A.; Gendrin, R.; Kennel, C. F.; Scarf, F. L.; Shawhan, S. D.
1992-01-01
The purpose of the Galileo plasma wave investigation is to study plasma waves and radio emissions in the magnetosphere of Jupiter. The plasma wave instrument uses an electric dipole antenna to detect electric fields, and two search coil magnetic antennas to detect magnetic fields. The frequency range covered is 5 Hz to 5.6 MHz for electric fields and 5 Hz to 160 kHz for magnetic fields. Low time-resolution survey spectrums are provided by three on-board spectrum analyzers. In the normal mode of operation the frequency resolution is about 10 percent, and the time resolution for a complete set of electric and magnetic field measurements is 37.33 s. High time-resolution spectrums are provided by a wideband receiver. The wideband receiver provides waveform measurements over bandwidths of 1, 10, and 80 kHz. Compared to previous measurements at Jupiter this instrument has several new capabilities. These new capabilities include (1) both electric and magnetic field measurements to distinguish electrostatic and electromagnetic waves, (2) direction finding measurements to determine source locations, and (3) increased bandwidth for the wideband measurements.
Acoustic levitator for structure measurements on low temperature liquid droplets
NASA Astrophysics Data System (ADS)
Weber, J. K. R.; Rey, C. A.; Neuefeind, J.; Benmore, C. J.
2009-08-01
A single-axis acoustic levitator was constructed and used to levitate liquid and solid drops of 1-3 mm in diameter at temperatures in the range -40 to +40 °C. The levitator comprised (i) two acoustic transducers mounted on a rigid vertical support that was bolted to an optical breadboard, (ii) an acoustic power supply that controlled acoustic intensity, relative phase of the drive to the transducers, and could modulate the acoustic forces at frequencies up to 1 kHz, (iii) a video camera, and (iv) a system for providing a stream of controlled temperature gas flow over the sample. The acoustic transducers were operated at their resonant frequency of ˜22 kHz and could produce sound pressure levels of up to 160 dB. The force applied by the acoustic field could be modulated to excite oscillations in the sample. Sample temperature was controlled using a modified Cryostream Plus and measured using thermocouples and an infrared thermal imager. The levitator was installed at x-ray beamline 11 ID-C at the Advanced Photon Source and used to investigate the structure of supercooled liquids.
Validation and Continued Development of Methods for Spheromak Simulation
NASA Astrophysics Data System (ADS)
Benedett, Thomas
2016-10-01
The HIT-SI experiment has demonstrated stable sustainment of spheromaks. Determining how the underlying physics extrapolate to larger, higher-temperature regimes is of prime importance in determining the viability of the inductively-driven spheromak. It is thus prudent to develop and validate a computational model that can be used to study current results and study the effect of possible design choices on plasma behavior. A zero-beta Hall-MHD model has shown good agreement with experimental data at 14.5 kHz injector operation. Experimental observations at higher frequency, where the best performance is achieved, indicate pressure effects are important and likely required to attain quantitative agreement with simulations. Efforts to extend the existing validation to high frequency (36-68 kHz) using an extended MHD model implemented in the PSI-TET arbitrary-geometry 3D MHD code will be presented. An implementation of anisotropic viscosity, a feature observed to improve agreement between NIMROD simulations and experiment, will also be presented, along with investigations of flux conserver features and their impact on density control for future SIHI experiments. Work supported by DoE.
NASA Astrophysics Data System (ADS)
Kapica, Dominik; Warchulińska, Joanna; Jakubiak, Monika; Teter, Mariusz; Mlak, Radosław; Hałabiś, Magdalena; Wójcik, Waldemar; Małecka-Massalska, Teresa
2015-09-01
Introduction: Bioelectrical impedance analysis (BIA) is a useful tool to asses human body composition and nutrition status; multi-frequency BIA has a higher accuracy than single-frequency BIA. In our study a difference of impedance values (Z) at 5, 100 and 200 kHz and Z200/Z5 index between professional athletes and control group were determined. Methods: In this research 105 people were tested, divided into control group (72 people: 35 males and 37 females) and professional athletes (33 people: 16 males and 17 females). Impedance was measured at three frequency values - 5, 100 and 200 kHz; with received values the Z200/Z5 index was calculated. Results: In most compared subgroups impedance values showed significantly lower values in athletes than in control group (5 kHz - males: p=0.136, females: p=0.001, 100 kHz - males: p=0.039, females: p<0.0001, 200 kHz - males: p=0.047, females: p<0.0001) Z200/Z5 index also showed lower value in athletes than in control group (p=0.016 for males, p<0.0001 for females). Conclusion: Lower values of impedance and Z200/Z5 index indicates a better nutrition status and general health condition of athletes than in control group.
NASA Astrophysics Data System (ADS)
Finneran, James J.; Carder, Donald A.; Dear, Randall; Belting, Traci; McBain, Jim; Dalton, Les; Ridgway, Sam H.
2005-06-01
A behavioral response paradigm was used to measure pure-tone hearing sensitivities in two belugas (Delphinapterus leucas). Tests were conducted over a 20-month period at the Point Defiance Zoo and Aquarium, in Tacoma, WA. Subjects were two males, aged 8-10 and 9-11 during the course of the study. Subjects were born in an oceanarium and had been housed together for all of their lives. Hearing thresholds were measured using a modified up/down staircase procedure and acoustic response paradigm where subjects were trained to produce audible responses to test tones and to remain quiet otherwise. Test frequencies ranged from approximately 2 to 130 kHz. Best sensitivities ranged from approximately 40 to 50 dB re 1 μPa at 50-80 kHz and 30-35 kHz for the two subjects. Although both subjects possessed traditional ``U-shaped'' mammalian audiograms, one subject exhibited significant high-frequency hearing loss above 37 kHz compared to previously published data for belugas. Hearing loss in this subject was estimated to approach 90 dB for frequencies above 50 kHz. Similar ages, ancestry, and environmental conditions between subjects, but a history of ototoxic drug administration in only one subject, suggest that the observed hearing loss was a result of the aminoglycoside antibiotic amikacin. .
Finneran, James J; Carder, Donald A; Dear, Randall; Belting, Traci; McBain, Jim; Dalton, Les; Ridgway, Sam H
2005-06-01
A behavioral response paradigm was used to measure pure-tone hearing sensitivities in two belugas (Delphinapterus leucas). Tests were conducted over a 20-month period at the Point Defiance Zoo and Aquarium, in Tacoma, WA. Subjects were two males, aged 8-10 and 9-11 during the course of the study. Subjects were born in an oceanarium and had been housed together for all of their lives. Hearing thresholds were measured using a modified up/down staircase procedure and acoustic response paradigm where subjects were trained to produce audible responses to test tones and to remain quiet otherwise. Test frequencies ranged from approximately 2 to 130 kHz. Best sensitivities ranged from approximately 40 to 50 dB re 1 microPa at 50-80 kHz and 30-35 kHz for the two subjects. Although both subjects possessed traditional "U-shaped" mammalian audiograms, one subject exhibited significant high-frequency hearing loss above 37 kHz compared to previously published data for belugas. Hearing loss in this subject was estimated to approach 90 dB for frequencies above 50 kHz. Similar ages, ancestry, and environmental conditions between subjects, but a history of ototoxic drug administration in only one subject, suggest that the observed hearing loss was a result of the aminoglycoside antibiotic amikacin.
NASA Astrophysics Data System (ADS)
Wendelboe, Gorm
2018-06-01
A SeaBat T50 calibration that combines measurements in a test tank with data from numerical models is presented. The calibration is assessed with data obtained from a series of tests conducted over a sandy seabed outside the harbor of Santa Barbara, California (April 2016). The tests include different tone-burst durations, sound pressure levels, and receive gains in order to verify that the estimated seabed backscattering strength (S_b) is invariant to sonar settings. Finally, S_b-estimates obtained in the frequency range from 190 kHz in steps of 10 kHz up to 400 kHz, and for grazing angles from 20° up to 90° in bins of width 5°, are presented. The results are compared with results found in the literature.
2- to 3-kHz continuum emissions as possible indications of global heliospheric 'breathing'
NASA Technical Reports Server (NTRS)
Grzedzielski, S.; Lazarus, A. J.
1993-01-01
The paper analyzes the main features of 2- to 3-kHz heliospheric emissions in the context of a general heliospheric 'breathing' as inferred from the Voyager 2 solar wind average ram pressure data. Triggers for the three 3-kHz emission events seen to date are suggested, and good agreement is obtained in timing and expected postshock frequency for termination shock distances of about 90 AU. It is suggested that the visibility of the individual 3-kHz events and their observed upward frequency drift are enhanced when the postulated global heliospheric expansion results in the formation of a transient, compressed external plasma barrier around the heliopause that prevents radiation escape for several months. The average termination shock distance is estimated to be in the range 80-90 AU.
Underwater audiogram of a tucuxi (Sotalia fluviatilis guianensis).
Sauerland, M; Dehnhardt, G
1998-02-01
Using a go/no go response paradigm, a tucuxi (Sotalia fluviatilis guianensis) was trained to respond to pure-tone signals for an underwater hearing test. Auditory thresholds were obtained from 4 to 135 kHz. The audiogram curve shows that this Sotalia had an upper limit of hearing at 135 kHz; from 125 to 135 kHz sensitivity decreased by 475 dB/oct. This coincides with results from electrophysiological threshold measurements. The range of best hearing (defined as 10 dB from maximum sensitivity) was between 64 and 105 kHz. This range appears to be narrower and more restricted to higher frequencies in Sotalia fluviatilis guianensis than in other odontocete species that had been tested before. Peak frequencies of echolocation pulses reported from free-ranging Sotalia correspond with the range of most sensitive hearing of this test subject.
Atlantic bottlenose dolphin (Tursiops truncatus) hearing threshold for brief broadband signals.
Au, Whitlow W L; Lemonds, David W; Vlachos, Stephanie; Nachtigall, Paul E; Roitblat, Herbert L
2002-06-01
The hearing sensitivity of an Atlantic bottlenose dolphin (Tursiops truncatus) to both pure tones and broadband signals simulating echoes from a 7.62-cm water-filled sphere was measured. Pure tones with frequencies between 40 and 140 kHz in increments of 20 kHz were measured along with broadband thresholds using a stimulus with a center frequency of 97.3 kHz and 88.2 kHz. The pure-tone thresholds were compared with the broadband thresholds by converting the pure-tone threshold intensity to energy flux density. The results indicated that dolphins can detect broadband signals slightly better than a pure-tone signal. The broadband results suggest that an echolocating bottlenose dolphin should be able to detect a 7.62-cm diameter water-filled sphere out to a range of 178 m in a quiet environment.
Performance testing of a high frequency link converter for Space Station power distribution system
NASA Technical Reports Server (NTRS)
Sul, S. K.; Alan, I.; Lipo, T. A.
1989-01-01
The testing of a brassboard version of a 20-kHz high-frequency ac voltage link prototype converter dynamics for Space Station application is presented. The converter is based on a three-phase six-pulse bridge concept. The testing includes details of the operation of the converter when it is driving an induction machine source/load. By adapting a field orientation controller (FOC) to the converter, four-quadrant operation of the induction machine from the converter has been achieved. Circuit modifications carried out to improve the performance of the converter are described. The performance of two 400-Hz induction machines powered by the converter with simple V/f regulation mode is reported. The testing and performance results for the converter utilizing the FOC, which provides the capability for rapid torque changes, speed reversal, and four-quadrant operation, are reported.
Water-gel for gating graphene transistors.
Kim, Beom Joon; Um, Soong Ho; Song, Woo Chul; Kim, Yong Ho; Kang, Moon Sung; Cho, Jeong Ho
2014-05-14
Water, the primary electrolyte in biology, attracts significant interest as an electrolyte-type dielectric material for transistors compatible with biological systems. Unfortunately, the fluidic nature and low ionic conductivity of water prevents its practical usage in such applications. Here, we describe the development of a solid state, megahertz-operating, water-based gate dielectric system for operating graphene transistors. The new electrolyte systems were prepared by dissolving metal-substituted DNA polyelectrolytes into water. The addition of these biocompatible polyelectrolytes induced hydrogelation to provide solid-state integrity to the system. They also enhanced the ionic conductivities of the electrolytes, which in turn led to the quick formation of an electric double layer at the graphene/electrolyte interface that is beneficial for modulating currents in graphene transistors at high frequencies. At the optimized conditions, the Na-DNA water-gel-gated flexible transistors and inverters were operated at frequencies above 1 MHz and 100 kHz, respectively.
Design considerations for large space electric power systems
NASA Technical Reports Server (NTRS)
Renz, D. D.; Finke, R. C.; Stevens, N. J.; Triner, J. E.; Hansen, I. G.
1983-01-01
As power levels of spacecraft rise to the 50 to 100 kW range, it becomes apparent that low voltage (28 V) dc power distribution and management systems will not operate efficiently at these higher power levels. The concept of transforming a solar array voltage at 150 V dc into a 1000 V ac distribution system operating at 20 kHz is examined. The transformation is accomplished with series-resonant inverter by using a rotary transformer to isolate the solar array from the spacecraft. The power can then be distributed in any desired method such as three phase delta to delta. The distribution voltage can be easily transformed to any desired load voltage and operating frequency. The reasons for the voltage limitations on the solar array due to plasma interactions and the many advantages of a high voltage, high frequency at distribution system are discussed.
NASA Technical Reports Server (NTRS)
Kurth, W. S.
1984-01-01
The Plasma Diagnostics Package, which was flown aboard STS-3 recorded various chemical releases from the Orbiter. Changes in the plasma environment were observed to occur during Flash Evaporator System (FES) releases, water dumps and maneuvering thruster operations. During flash evaporator operations, broadband Orbiter-generated electro-static noise is enhanced and plasma density irregularity (delta n/N) is observed to increase by as much as 4 times and is strongly peaked below 6 Hz. In the case of water dumps, background electrostatic noise is enhanced or suppressed depending on frequency and Delta N/N is also seen to increase by as much as 4 times. Various changes in the plasma environment are effected by primary and vernier thruster operations. In addition, thruster activity stimulates electrostatic noise with a spectrum which is most intense at frequencies below 10 kHz.
Electromechanical Frequency Filters
NASA Astrophysics Data System (ADS)
Wersing, W.; Lubitz, K.
Frequency filters select signals with a frequency inside a definite frequency range or band from signals outside this band, traditionally afforded by a combination of L-C-resonators. The fundamental principle of all modern frequency filters is the constructive interference of travelling waves. If a filter is set up of coupled resonators, this interference occurs as a result of the successive wave reflection at the resonators' ends. In this case, the center frequency f c of a filter, e.g., set up of symmetrical λ/2-resonators of length 1, is given by f_c = f_r = v_{ph}/λ = v_{ph}/2l , where v ph is the phase velocity of the wave. This clearly shows the big advantage of acoustic waves for filter applications in comparison to electro-magnetic waves. Because v ph of acoustic waves in solids is about 104-105 smaller than that of electro-magnetic waves, much smaller filters can be realised. Today, piezoelectric materials and processing technologies exist that electromechanical resonators and filters can be produced in the frequency range from 1 kHz up to 10 GHz. Further requirements for frequency filters such as low losses (high resonator Q) and low temperature coefficients of frequency constants can also be fulfilled with these filters. Important examples are quartz-crystal resonators and filters (1 kHz-200 MHz) as discussed in Chap. 2, electromechanical channel filters (50 kHz and 130 kHz) for long-haul communication systems as discussed in this section, surface acoustic wave (SAW) filters (20 MHz-5 GHz), as discussed in Chap. 14, and thin film bulk acoustic resonators (FBAR) and filters (500 MHz-10 GHz), as discussed in Chap. 15.
Simple piezoelectric-actuated mirror with 180 kHz servo bandwidth.
Briles, Travis C; Yost, Dylan C; Cingöz, Arman; Ye, Jun; Schibli, Thomas R
2010-05-10
We present a high bandwidth piezoelectric-actuated mirror for length stabilization of an optical cavity. The actuator displays a transfer function with a flat amplitude response and greater than 135 masculine phase margin up to 200 kHz, allowing a 180 kHz unity gain frequency to be achieved in a closed servo loop. To the best of our knowledge, this actuator has achieved the largest servo bandwidth for a piezoelectric transducer (PZT). The actuator should be very useful in a wide variety of applications requiring precision control of optical lengths, including laser frequency stabilization, optical interferometers, and optical communications. (c) 2010 Optical Society of America.
Echolocation behavior of franciscana dolphins (Pontoporia blainvillei) in the wild.
Melcón, Mariana L; Failla, Mauricio; Iñíguez, Miguel A
2012-06-01
Franciscana dolphins are small odontocetes hard to study in the field. In particular, little is known on their echolocation behavior in the wild. In this study we recorded 357 min and analyzed 1019 echolocation signals in the Rio Negro Estuary, Argentina. The clicks had a peak frequency at 139 kHz, and a bandwidth of 19 kHz, ranging from 130 to 149 kHz. This is the first study describing echolocation signals of franciscana dolphins in the wild, showing the presence of narrow-band high frequency signals in these dolphins. Whether they use other vocalizations to communicate or not remains uncertain.
A detector for high frequency modulation in auroral particle fluxes
NASA Technical Reports Server (NTRS)
Spiger, R. J.; Oehme, D.; Loewenstein, R. F.; Murphree, J.; Anderson, H. R.; Anderson, R.
1974-01-01
A high time resolution electron detector has been developed for use in sounding rocket studies of the aurora. The detector is used to look for particle bunching in the range 50 kHz-10 MHz. The design uses an electron multiplier and an onboard frequency spectrum analyzer. By using the onboard analyzer, the data can be transmitted back to ground on a single 93-kHz voltage-controlled oscillator. The detector covers the 50 kHz-10 MHz range six times per second and detects modulation on the order of a new percent of the total electron flux. Spectra are presented for a flight over an auroral arc.
Frequency Response of Graphene Electrolyte-Gated Field-Effect Transistors
McVay, Elaine; Palacios, Tomás
2018-01-01
This work develops the first frequency-dependent small-signal model for graphene electrolyte-gated field-effect transistors (EGFETs). Graphene EGFETs are microfabricated to measure intrinsic voltage gain, frequency response, and to develop a frequency-dependent small-signal model. The transfer function of the graphene EGFET small-signal model is found to contain a unique pole due to a resistive element, which stems from electrolyte gating. Intrinsic voltage gain, cutoff frequency, and transition frequency for the microfabricated graphene EGFETs are approximately 3.1 V/V, 1.9 kHz, and 6.9 kHz, respectively. This work marks a critical step in the development of high-speed chemical and biological sensors using graphene EGFETs. PMID:29414868
Thakore, Neha; Reno, James M.; Gonzales, Rueben A.; Schallert, Timothy; Bell, Richard L.; Maddox, W. Todd; Duvauchelle, Christine L.
2016-01-01
Heightened emotional states increase impulsive behaviors such as excessive ethanol consumption in humans. Though positive and negative affective states in rodents can be monitored in real-time through ultrasonic vocalization (USV) emissions, few animal studies have focused on the role of emotional status as a stimulus for initial ethanol drinking. Our laboratory has recently developed reliable, high-speed analysis techniques to compile USV data during multiple-hour drinking sessions. Since High Alcohol Drinking (HAD-1) rats are selectively bred to voluntarily consume intoxicating levels of alcohol, we hypothesized that USVs emitted by HAD-1 rats would reveal unique emotional phenotypes predictive of alcohol intake and sensitive to alcohol experience. In this study, male HAD-1 rats had access to water, 15% and 30% EtOH or water only (i.e., Controls) during 8 weeks of daily 7-hr drinking-in-the-dark (DID) sessions. USVs, associated with both positive (i.e., 50–55 kHz frequency-modulated or FM) and negative (i.e., 22–28 kHz) emotional states, emitted during these daily DID sessions were examined. Findings showed basal 22–28 kHz USVs were emitted by both EtOH-Naïve (Control) and EtOH-experienced rats, alcohol experience enhanced 22–28 kHz USV emissions, and USV acoustic parameters (i.e., mean frequency in kHz) of both positive and negative USVs were significantly suppressed by chronic alcohol experience. These data suggest that negative affective status initiates and maintains excessive alcohol intake in selectively bred HAD-1 rats and support the notion that unprovoked emissions of negative affect-associated USVs (i.e., 22–28 kHz) predict vulnerability to excessive alcohol intake in distinct rodent models. PMID:26802730
Noh, Heil; Lee, Dong-Hee
2012-01-01
To identify the quantitative differences between Korean and English in long-term average speech spectra (LTASS). Twenty Korean speakers, who lived in the capital of Korea and spoke standard Korean as their first language, were compared with 20 native English speakers. For the Korean speakers, a passage from a novel and a passage from a leading newspaper article were chosen. For the English speakers, the Rainbow Passage was used. The speech was digitally recorded using GenRad 1982 Precision Sound Level Meter and GoldWave® software and analyzed using MATLAB program. There was no significant difference in the LTASS between the Korean subjects reading a news article or a novel. For male subjects, the LTASS of Korean speakers was significantly lower than that of English speakers above 1.6 kHz except at 4 kHz and its difference was more than 5 dB, especially at higher frequencies. For women, the LTASS of Korean speakers showed significantly lower levels at 0.2, 0.5, 1, 1.25, 2, 2.5, 6.3, 8, and 10 kHz, but the differences were less than 5 dB. Compared with English speakers, the LTASS of Korean speakers showed significantly lower levels in frequencies above 2 kHz except at 4 kHz. The difference was less than 5 dB between 2 and 5 kHz but more than 5 dB above 6 kHz. To adjust the formula for fitting hearing aids for Koreans, our results based on the LTASS analysis suggest that one needs to raise the gain in high-frequency regions.
Thakore, Neha; Reno, James M; Gonzales, Rueben A; Schallert, Timothy; Bell, Richard L; Maddox, W Todd; Duvauchelle, Christine L
2016-04-01
Heightened emotional states increase impulsive behaviors such as excessive ethanol consumption in humans. Though positive and negative affective states in rodents can be monitored in real-time through ultrasonic vocalization (USV) emissions, few animal studies have focused on the role of emotional status as a stimulus for initial ethanol drinking. Our laboratory has recently developed reliable, high-speed analysis techniques to compile USV data during multiple-hour drinking sessions. Since High Alcohol Drinking (HAD-1) rats are selectively bred to voluntarily consume intoxicating levels of alcohol, we hypothesized that USVs emitted by HAD-1 rats would reveal unique emotional phenotypes predictive of alcohol intake and sensitive to alcohol experience. In this study, male HAD-1 rats had access to water, 15% and 30% EtOH or water only (i.e., Controls) during 8 weeks of daily 7-h drinking-in-the-dark (DID) sessions. USVs, associated with both positive (i.e., 50-55 kHz frequency-modulated or FM) and negative (i.e., 22-28 kHz) emotional states, emitted during these daily DID sessions were examined. Findings showed basal 22-28 kHz USVs were emitted by both EtOH-Naïve (Control) and EtOH-experienced rats, alcohol experience enhanced 22-28 kHz USV emissions, and USV acoustic parameters (i.e., mean frequency in kHz) of both positive and negative USVs were significantly suppressed by chronic alcohol experience. These data suggest that negative affective status initiates and maintains excessive alcohol intake in selectively bred HAD-1 rats and support the notion that unprovoked emissions of negative affect-associated USVs (i.e., 22-28 kHz) predict vulnerability to excessive alcohol intake in distinct rodent models. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Kumamoto, A.; Tsuchiya, F.; Kasahara, Y.; Kasaba, Y.; Kojima, H.; Yagitani, S.; Ishisaka, K.; Imachi, T.; Ozaki, M.; Matsuda, S.; Shoji, M.; Matsuoka, A.; Katoh, Y.; Miyoshi, Y.; Shinohara, I.; Obara, T.
2017-12-01
High Frequency Analyzer (HFA) is a subsystem of the Plasma Wave Experiment (PWE) onboard the ARASE (ERG, Exploration of energization and Radiation in Geospace) spacecraft for observation of radio and plasma waves in a frequency range from 0.01 to 10 MHz. In ARASE mission, HFA is expected to perform the following observations: (1) Upper hybrid resonance (UHR) waves in order to determine the electron number density around the spacecraft. (2) Magnetic field component of the chorus waves in a frequency range from 20 kHz to 100 kHz. (3) Radio and plasma waves excited via wave particle interactions and mode conversion processes in storm-time magnetosphere.HFA is operated in the following three observation modes: EE-mode, EB-mode, and PP-mode. In far-Earth region, HFA is operated in EE-mode. Spectrogram of two orthogonal or right and left-handed components of electric field in perpendicular directions to the spin axis of the spacecraft are obtained. In the near-Earth region, HFA is operated in EB-mode. Spectrogram of one components of electric field in perpendicular direction to the spin plane, and one component of the magnetic field in parallel direction to the spin axis are obtained. In EE and EB-modes, the frequency range from 0.01 to 10 MHz are covered with 480 frequency steps. The time resolution is 8 sec. We also prepared PP mode to measure the locations and structures of the plasmapause at higher resolution. In PP-mode, spectrogram of one electric field component in a frequency range from 0.01-0.4 MHz (PP1) or 0.1-1 MHz (PP2) can be obtained at time resolution of 1 sec.After the successful deployment of the wire antenna and search coils mast and initial checks, we could start routine observations and detect various radio and plasma wave phenomena such as upper hybrid resonance (UHR) waves, electrostatic electron cyclotron harmonic (ESCH) waves, auroral kilometric radiation (AKR), kilometric continuum (KC) and Type-III solar radio bursts. In the presentation, we will report the initial results based on the datasets obtained since January 2017 focusing on the analyses of plasmasphere evolution by semi-automatic identification of UHR frequency, and AKR from the both hemisphere based on polarization measurement.
NASA Technical Reports Server (NTRS)
Hansen, Irving G.
1990-01-01
Electromechanical actuators developed to date have commonly utilized permanent magnet (PM) synchronous motors. More recently switched reluctance (SR) motors have been advocated due to their robust characteristics. Implications of work which utilizes induction motors and advanced control techniques are discussed. When induction motors are operated from an energy source capable of controlling voltages and frequencies independently, drive characteristics are obtained which are superior to either PM or SR motors. By synthesizing the machine frequency from a high frequency carrier (nominally 20 kHz), high efficiencies, low distortion, and rapid torque response are available. At this time multiple horsepower machine drives were demonstrated, and work is on-going to develop a 20 hp average, 40 hp peak class of aerospace actuators. This effort is based upon high frequency power distribution and management techniques developed by NASA for Space Station Freedom.
NASA Technical Reports Server (NTRS)
Hansen, Irving G.
1990-01-01
Electromechanical actuators developed to date have commonly ultilized permanent magnet (PM) synchronous motors. More recently switched reluctance (SR) motors have been advocated due to their robust characteristics. Implications of work which utilized induction motors and advanced control techniques are discussed. When induction motors are operated from an energy source capable of controlling voltages and frequencies independently, drive characteristics are obtained which are superior to either PM or SR motors. By synthesizing the machine frequency from a high-frequency carrier (nominally 20 kHz), high efficiencies, low distortion, and rapid torque response are available. At this time multiple horsepower machine drives were demonstrated, and work is on-going to develop a 20 hp average, 40 hp peak class of aerospace actuators. This effort is based upon high-frequency power distribution and management techniques developed by NASA for Space Station Freedom.
NASA Astrophysics Data System (ADS)
Xiong, C. Y.; Chen, J.; Li, Q.; Liu, Y.; Gao, L.
2014-12-01
A three-wave laser polarimeter-interferometer, equipped with three independent far-infrared laser sources, has been developed on Joint-TEXT (J-TEXT) tokamak. The diagnostic system is capable of high-resolution temporal and phase measurement of the Faraday angle and line-integrated density. However, for long-term operation (>10 min), the free-running lasers can lead to large drifts of the intermediate frequencies (˜100-˜500 kHz/10 min) and decay of laser power (˜10%-˜20%/10 min), which act to degrade diagnostic performance. In addition, these effects lead to increased maintenance cost and limit measurement applicability to long pulse/steady state experiments. To solve this problem, a real-time feedback control method of the laser source is proposed. By accurately controlling the length of each laser cavity, both the intermediate frequencies and laser power can be simultaneously controlled: the intermediate frequencies are controlled according to the pre-set values, while the laser powers are maintained at an optimal level. Based on this approach, a real-time feedback control system has been developed and applied on J-TEXT polarimeter-interferometer. Long-term (theoretically no time limit) feedback of intermediate frequencies (maximum change less than ±12 kHz) and laser powers (maximum relative power change less than ±7%) has been successfully achieved.
Xiong, C Y; Chen, J; Li, Q; Liu, Y; Gao, L
2014-12-01
A three-wave laser polarimeter-interferometer, equipped with three independent far-infrared laser sources, has been developed on Joint-TEXT (J-TEXT) tokamak. The diagnostic system is capable of high-resolution temporal and phase measurement of the Faraday angle and line-integrated density. However, for long-term operation (>10 min), the free-running lasers can lead to large drifts of the intermediate frequencies (∼100-∼500 kHz/10 min) and decay of laser power (∼10%-∼20%/10 min), which act to degrade diagnostic performance. In addition, these effects lead to increased maintenance cost and limit measurement applicability to long pulse/steady state experiments. To solve this problem, a real-time feedback control method of the laser source is proposed. By accurately controlling the length of each laser cavity, both the intermediate frequencies and laser power can be simultaneously controlled: the intermediate frequencies are controlled according to the pre-set values, while the laser powers are maintained at an optimal level. Based on this approach, a real-time feedback control system has been developed and applied on J-TEXT polarimeter-interferometer. Long-term (theoretically no time limit) feedback of intermediate frequencies (maximum change less than ±12 kHz) and laser powers (maximum relative power change less than ±7%) has been successfully achieved.
Multiplexing Readout of TES Microcalorimeters Based on Analog Baseband Feedback
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takei, Y.; Yamasaki, N.Y; Mitsuda, K.
2009-12-16
A TES microcalorimeter array is a promising spectrometer with excellent energy resolution and a moderate imaging capability. To realize a large format array in space, multiplexing the TES signals at the low tempersture stage is mandatory. We are developing frequency division multiplexing (FDM) based on baseband feedback technique. In FDM, each TES is AC-biased with a different carrier frequency. Signals from several pixels are summed and then read out by one SQUID. The maximum number of multiplexed pixels are limited by the frequency band in which the SQUID can be operated in a flux-locked loop, which is {approx}1 MHz withmore » standard flux-locked loop circuit. In the baseband feedback, the signal ({approx}10 kHz band) from the TES is once demodulated. Then a reconstructed copy of the modulated signal with an appropriate phase is fed back to the SQUID input coil to maintain an approximately constant magnetic flux. This can be implemented even for large cable delays and automatically suppresses the carrier. We developed a prototype electronics for the baseband feedback based on an analog phase sensitive detector (PSD) and a multiplier. Combined with Seiko 80-SSA SQUID amp, open-loop gain of 8 has been obtained for 10 kHz baseband signal at 5 MHz carrier frequency, with a moderate noise contribution of 27pA/{radical}(Hz) at input.« less
20 kHz main inverter unit. [for space station power supplies
NASA Technical Reports Server (NTRS)
Hussey, S.
1989-01-01
A proof-of-concept main inverter unit has demonstrated the operation of a pulse-width-modulated parallel resonant power stage topology as a 20-kHz ac power source driver, showing simple output regulation, parallel operation, power sharing and short-circuit operation. The use of a two-stage dc input filter controls the electromagnetic compatibility (EMC) characteristics of the dc power bus, and the use of an ac harmonic trap controls the EMC characteristics of the 20-kHz ac power bus.
High frequency analysis of cough sounds in pediatric patients with respiratory diseases.
Kosasih, K; Abeyratne, U R; Swarnkar, V
2012-01-01
Cough is a common symptom in a range of respiratory diseases and is considered a natural defense mechanism of the body. Despite its critical importance in the diagnosis of illness, there are no golden methods to objectively assess cough. In a typical consultation session, a physician may briefly listen to the cough sounds using a stethoscope placed against the chest. The physician may also listen to spontaneous cough sounds via naked ears, as they naturally propagate through air. Cough sounds carry vital information on the state of the respiratory system but the field of cough analysis in clinical medicine is in its infancy. All existing cough analysis approaches are severely handicapped by the limitations of the human hearing range and simplified analysis techniques. In this paper, we address these problems, and explore the use of frequencies covering a range well beyond the human perception (up to 90 kHz) and use wavelet analysis to extract diagnostically important information from coughs. Our data set comes from a pediatric respiratory ward in Indonesia, from subjects diagnosed with asthma, pneumonia and rhinopharyngitis. We analyzed over 90 cough samples from 4 patients and explored if high frequencies carried useful information in separating these disease groups. Multiple regression analysis resulted in coefficients of determination (R(2)) of 77-82% at high frequencies (15 kHz-90 kHz) indicating that they carry useful information. When the high frequencies were combined with frequencies below 15kHz, the R(2) performance increased to 85-90%.
Low Frequency Plasma Oscillations in a 6-kW Magnetically Shielded Hall Thruster
NASA Technical Reports Server (NTRS)
Jorns, Benjamin A.; Hofery, Richard R.
2013-01-01
The oscillations from 0-100 kHz in a 6-kW magnetically shielded thruster are experimen- tally characterized. Changes in plasma parameters that result from the magnetic shielding of Hall thrusters have the potential to significantly alter thruster transients. A detailed investigation of the resulting oscillations is necessary both for the purpose of determin- ing the underlying physical processes governing time-dependent behavior in magnetically shielded thrusters as well as for improving thruster models. In this investigation, a high speed camera and a translating ion saturation probe are employed to examine the spatial extent and nature of oscillations from 0-100 kHz in the H6MS thruster. Two modes are identified at 8 kHz and 75-90 kHz. The low frequency mode is azimuthally uniform across the thruster face while the high frequency oscillation is concentrated close to the thruster centerline with an m = 1 azimuthal dependence. These experimental results are discussed in the context of wave theory as well as published observations from an unshielded variant of the H6MS thruster.
Active MHD Spectroscopy of Alfvén Eigenmodes on Alcator C-Mod
NASA Astrophysics Data System (ADS)
Sears, J.; Snipes, J.; Burke, W.; Parker, R.; Fasoli, A.
2004-11-01
Alfvén eigenmode resonances are excited in a variety of plasma conditions in C-Mod with two moderate-n antennas positioned above and below the outboard midplane. Power amplifiers (≈ 3 kW) sweep the driving frequency over the audio range (< 30 kHz) or over a selected ± 50 kHz range from 100 kHz to 1 MHz. Logic circuitry that calculates the center frequency of the Toroidal Alfven Eigenmode gap, f_TAE=v_A/4π qR, in real-time from BT and e measurements is being developed to enable the antennas to track f_TAE. Simultaneous in-vessel phase calibration of the pick-up coils will be used to better identify toroidal mode numbers. Shot-to-shot elongation scans do not show the dependence of damping on edge shear that was seen in results at JET. Inner wall limited plasmas with moderate outer gaps show higher damping rates than diverted plasmas with low outer gaps. Low frequency experiments below 20kHz will also be presented.
Bulog, B; Schlegel, P
2000-01-01
Octavolateral sensory organs (auditory and lateral line organs) of cave salamander Proteus anguinus are highly differentiated. In the saccular macula of the inner ear the complex pattern of hair cell orientation and the large otoconial mass enable particle displacement direction detection. Additionally, the same organ, through air cavities within the body, enables detection of underwater sound pressure changes thus acting as a hearing organ. The cavities in the lungs and mouth of Proteus are a resonators that transmit underwater sound pressure to the inner ear. Behaviourally determined audiograms indicate hearing sensitivity of 60 dB (rel. 1 microPa) at frequencies between 1 and 10 kHz. The hearing frequency range was between 10 Hz and 10 kHz. The hearing sensitivities of depigmented Proteus and black Proteus were compared. The highest sensitivities of the depigmented animals (N=4) were at frequencies 1.3-1.7 kHz and it was 2 kHz in black animals (N=1). Excellent underwater hearing abilities of Proteus are sensory adaptations to cave habitat.
NASA Astrophysics Data System (ADS)
Yoon, Eun-A.; Hwang, Doo-Jin; Chae, Jinho; Yoon, Won Duk; Lee, Kyounghoon
2018-03-01
This study was carried out to determine the in situ target strength and behavioral characteristics of moon jellyfish ( Aurelia aurita) using two frequencies (38 and 120 kHz) that present a 2- frequency-difference method for distinguishing A. aurita from other marine planktonic organisms. The average TS was shown as -71.9 -67.9 dB at 38 kHz and -75.5 -66.0 dB at 120 kHz and the average ΔMVBS120-38 kHz was similar at -1.5 3.5 dB. The TS values varied in a range of about 14 dB from -83.3 and -69.0 dB depending on the pulsation of A. aurita. The species moved in a range of -0.1 1.0 m and they mostly moved horizontally with moving speeds of 0.3 0.6 m·s-1. The TS and behavioral characteristics of A. aurita can distinguish the species from others. The acoustic technology can also contribute to understanding the distribution and abundance of the species.
Plasticity of peripheral auditory frequency sensitivity in Emei music frog.
Zhang, Dian; Cui, Jianguo; Tang, Yezhong
2012-01-01
In anurans reproductive behavior is strongly seasonal. During the spring, frogs emerge from hibernation and males vocalize for mating or advertising territories. Female frogs have the ability to evaluate the quality of the males' resources on the basis of these vocalizations. Although studies revealed that central single torus semicircularis neurons in frogs exhibit season plasticity, the plasticity of peripheral auditory sensitivity in frog is unknown. In this study the seasonally plasticity of peripheral auditory sensitivity was test in the Emei music frog Babina daunchina, by comparing thresholds and latencies of auditory brainstem responses (ABRs) evoked by tone pips and clicks in the reproductive and non-reproductive seasons. The results show that both ABR thresholds and latency differ significantly between the reproductive and non-reproductive seasons. The thresholds of tone pip evoked ABRs in the non-reproductive season increased significantly about 10 dB than those in the reproductive season for frequencies from 1 KHz to 6 KHz. ABR latencies to waveform valley values for tone pips for the same frequencies using appropriate threshold stimulus levels are longer than those in the reproductive season for frequencies from 1.5 to 6 KHz range, although from 0.2 to 1.5 KHz range it is shorter in the non-reproductive season. These results demonstrated that peripheral auditory frequency sensitivity exhibits seasonal plasticity changes which may be adaptive to seasonal reproductive behavior in frogs.
Two-tone suppression of stimulus frequency otoacoustic emissionsa)
Keefe, Douglas H.; Ellison, John C.; Fitzpatrick, Denis F.; Gorga, Michael P.
2008-01-01
Stimulus frequency otoacoustic emissions (SFOAEs) measured using a suppressor tone in human ears are analogous to two-tone suppression responses measured mechanically and neurally in mammalian cochleae. SFOAE suppression was measured in 24 normal-hearing adults at octave frequencies (fp=0.5–8.0 kHz) over a 40 dB range of probe levels (Lp). Suppressor frequencies (fs) ranged from −2.0 to 0.7 octaves re: fp, and suppressor levels ranged from just detectable suppression to full suppression. The lowest suppression thresholds occurred for “best” fs slightly higher than fp. SFOAE growth of suppression (GOS) had slopes close to one at frequencies much lower than best fs, and shallow slopes near best fs, which indicated compressive growth close to 0.3 dB/dB. Suppression tuning curves constructed from GOS functions were well defined at 1, 2, and 4 kHz, but less so at 0.5 and 8.0 kHz. Tuning was sharper at lower Lp with an equivalent rectangular bandwidth similar to that reported behaviorally for simultaneous masking. The tip-to-tail difference assessed cochlear gain, increasing with decreasing Lp and increasing fp at the lowest Lp from 32 to 45 dB for fp from 1 to 4 kHz. SFOAE suppression provides a noninvasive measure of the saturating nonlinearities associated with cochlear amplification on the basilar membrane. PMID:18345837
NASA Astrophysics Data System (ADS)
Ling, Yuye; Hendon, Christine P.
2017-02-01
Phase-resolved optical coherence tomography (OCT), a functional extension of OCT, provides depth-resolved phase information with extra contrast. In cardiology, changes in the mechanical properties have been associated with tissue remodeling and disease progression. Here we present the capability of profiling structural deformation of the sample in vivo by using a highly stable swept source OCT system The system, operating at 1300 nm, has an A-line acquisition rate of 200 kHz. We measured the phase noise floor to be 6.5 pm±3.2 pm by placing a cover slip in the sample arm, while blocking the reference arm. We then conducted a vibrational frequency test by measuring the phase response from a polymer membrane stimulated by a pure tone acoustic wave from 10 kHz to 80 kHz. The measured frequency response agreed with the known stimulation frequency with an error < 0.005%. We further measured the phase response of 7 fresh swine hearts obtained from Green Village Packing Company through a mechanical stretching test, within 24 hours of sacrifice. The heart tissue was cut into a 1 mm slices and fixed on two motorized stages. We acquired 100,000 consecutive M-scans, while the sample is stretched at a constant velocity of 10 um/s. The depth-resolved phase image presents linear phase response over time at each depth, but the slope varies among tissue types. Our future work includes refining our experiment protocol to quantitatively measured the elastic modulus of the tissue in vivo and building a tissue classifier based on depth-resolved phase information.
Lucas, Kathleen M; Windmill, James F C; Robert, Daniel; Yack, Jayne E
2009-11-01
The ears of insects exhibit a broad functional diversity with the ability to detect sounds across a wide range of frequencies and intensities. In tympanal ears, the membrane is a crucial step in the transduction of the acoustic stimulus into a neural signal. The tropical butterfly Morpho peleides has an oval-shaped membrane at the base of the forewing with an unusual dome in the middle of the structure. We are testing the hypothesis that this unconventional anatomical arrangement determines the mechanical tuning properties of this butterfly ear. Using microscanning laser Doppler vibrometry to measure the vibrational characteristics of this novel tympanum, the membrane was found to vibrate in two distinct modes, depending on the frequency range: at lower frequencies (1-5 kHz) the vibration was focused at the proximal half of the posterior side of the outer membrane, while at higher frequencies (5-20 kHz) the entire membrane contributed to the vibration. The maximum deflection points of the two vibrational modes correspond to the locations of the associated chordotonal organs, suggesting that M. peleides has the capacity for frequency partitioning because of the different vibrational properties of the two membrane components. Extracellular nerve recordings confirm that the innervating chordotonal organs respond to the same frequency range of 1-20 kHz, and are most sensitive between 2 and 4 kHz, although distinct frequency discrimination was not observed. We suggest that this remarkable variation in structure is associated with function that provides a selective advantage, particularly in predator detection.
Wang, Zuojun; Komatsu, Teppei; Mitsumura, Hidetaka; Nakata, Norio; Ogawa, Takeki; Iguchi, Yasuyuki; Yokoyama, Masayuki
2017-05-01
Sonothrombolysis is one of the most feasible methods for enhancing clot lysis with a recombinant tissue plasminogen activator (rt-PA) in cases of acute ischemic strokes. For safe and efficient clinical practices of sonothrombolysis, accurate estimation of ultrasound transmittance through the human skull is critical. Previously, we reported substantial and periodic fluctuation of ultrasound transmittance through a bone-phantom plate following changes to ultrasound frequency, the thickness of the bone-phantom plate, and the distance between a transducer and the bone-phantom plate. In the present study, we clarify the transmittance behavior of medium-frequency ultrasound (from 400kHz to 600kHz) through the human skull, and examine reduction of the transmittance fluctuation. For the study, we measured transmittance of sinusoidal ultrasound waves at 400kHz, 500kHz, and 600kHz at 13 temple spots on 3 human skulls by changing the distance between a transducer and the skull bone, and found substantial and periodic fluctuation in the transmittance behaviors for these sinusoidal voltage excitations. Degrees of the fluctuation varied depending on the measurement spots. A fluctuation ratio between the maximum transmittance and the minimum transmittance reached 3 in some spots. This large transmittance fluctuation is considered to be a risk factor for sonothrombolysis therapies. We examined a modulated ultrasound wave to reduce the fluctuation, and succeeded in obtaining considerable reduction. The average fluctuation ratios for 400-kHz, 500-kHz, and 600-kHz waves were 2.38, 2.38, and 2.07, respectively. We successfully reduced the ratio to 1.72 by using a periodic selection of random frequency (PSRF)-type of modulation wave. The thus obtained results indicate that attention to the fluctuation in ultrasound transmittance through the skull is necessary for safe and effective sonothrombolysis therapies, and that modulated ultrasound waves constitute a powerful method for reducing the risk of fluctuation. Copyright © 2017 Elsevier B.V. All rights reserved.
Para-hydrogen induced polarization of amino acids, peptides and deuterium-hydrogen gas.
Glöggler, Stefan; Müller, Rafael; Colell, Johannes; Emondts, Meike; Dabrowski, Martin; Blümich, Bernhard; Appelt, Stephan
2011-08-14
Signal Amplification by Reversible-Exchange (SABRE) is a method of hyperpolarizing substrates by polarization transfer from para-hydrogen without hydrogenation. Here, we demonstrate that this method can be applied to hyperpolarize small amounts of all proteinogenic amino acids and some chosen peptides down to the nanomole regime and can be detected in a single scan in low-magnetic fields down to 0.25 mT (10 kHz proton frequency). An outstanding feature is that depending on the chemical state of the used catalyst and the investigated amino acid or peptide, hyperpolarized hydrogen-deuterium gas is formed, which was detected with (1)H and (2)H NMR spectroscopy at low magnetic fields of B(0) = 3.9 mT (166 kHz proton frequency) and 3.2 mT (20 kHz deuterium frequency).