Jahng, Geon-Ho; Jin, Wook; Yang, Dal Mo; Ryu, Kyung Nam
2011-05-01
We wanted to optimize a double inversion recovery (DIR) sequence to image joint effusion regions of the knee, especially intracapsular or intrasynovial imaging in the suprapatellar bursa and patellofemoral joint space. Computer simulations were performed to determine the optimum inversion times (TI) for suppressing both fat and water signals, and a DIR sequence was optimized based on the simulations for distinguishing synovitis from fluid. In vivo studies were also performed on individuals who showed joint effusion on routine knee MR images to demonstrate the feasibility of using the DIR sequence with a 3T whole-body MR scanner. To compare intracapsular or intrasynovial signals on the DIR images, intermediate density-weighted images and/or post-enhanced T1-weighted images were acquired. The timings to enhance the synovial contrast from the fluid components were TI1 = 2830 ms and TI2 = 254 ms for suppressing the water and fat signals, respectively. Improved contrast for the intrasynovial area in the knees was observed with the DIR turbo spin-echo pulse sequence compared to the intermediate density-weighted sequence. Imaging contrast obtained noninvasively with the DIR sequence was similar to that of the post-enhanced T1-weighted sequence. The DIR sequence may be useful for delineating synovium without using contrast materials.
[Destruction of synovial pannus of antigen-induced arthritis by ultrasonic cavitation in rabbits].
Zhang, Ling-yan; Qiu, Li; Wang, Lei; Lin, Ling; Wen, Xiao-rong
2011-11-01
To optimize the conditions of ultrasonic irradiation and microbubble of ultrasound cavitation on destruction of synovial pannus of antigen-induced arthritis (AIA) in rabbits. Antigen-induced arthritis was successfully induced on bilateral knee joints of 85 rabbits. Each 10 AIA rabbits were divided into two groups to compare various peak negative pressures, different ultrasonic pulse durations, various pulse repetition frequencies, different irradiance duration, different dosages of microbubble contrast agents, different ultrasonic irradiance times. With intravenous infusion of Sonovue to the rabbits, ultrasonic irradiance was performed on the right knee joint using the above condition of ultrasound cavitation. At the day 1 after ultrasonic irradiance, MRI and pathological examination were employed to evaluate the optimal conditions. The optimal parameters and conditions for ultrasonic irradiance included intermittent ultrasonic application (in 6 s intervals), 0.6 mL/kg of microbubble contrast agent, 4.6 MPa of ultrasonic peak negative pressure, 100 cycles of pulse duration, 50 Hz of pulse repetition frequency, 5 min of ultrasonic duration, 0.6 mL/kg of dosages of microbubble contrast agents and multi-sessional ultrasonic irradiance. After the ultrasonic irradiance, the thickness of right knee synovium measured by MRI was thinner than that of left knee and synovial necrosis was confirmed by the pathological finding. Under optimal ultrasonic irradiation and microbubble conditions, ultrasonic cavitation could destroy synovial pannus of AIA in rabbits.
Serrancolí, Gil; Kinney, Allison L.; Fregly, Benjamin J.; Font-Llagunes, Josep M.
2016-01-01
Though walking impairments are prevalent in society, clinical treatments are often ineffective at restoring lost function. For this reason, researchers have begun to explore the use of patient-specific computational walking models to develop more effective treatments. However, the accuracy with which models can predict internal body forces in muscles and across joints depends on how well relevant model parameter values can be calibrated for the patient. This study investigated how knowledge of internal knee contact forces affects calibration of neuromusculoskeletal model parameter values and subsequent prediction of internal knee contact and leg muscle forces during walking. Model calibration was performed using a novel two-level optimization procedure applied to six normal walking trials from the Fourth Grand Challenge Competition to Predict In Vivo Knee Loads. The outer-level optimization adjusted time-invariant model parameter values to minimize passive muscle forces, reserve actuator moments, and model parameter value changes with (Approach A) and without (Approach B) tracking of experimental knee contact forces. Using the current guess for model parameter values but no knee contact force information, the inner-level optimization predicted time-varying muscle activations that were close to experimental muscle synergy patterns and consistent with the experimental inverse dynamic loads (both approaches). For all the six gait trials, Approach A predicted knee contact forces with high accuracy for both compartments (average correlation coefficient r = 0.99 and root mean square error (RMSE) = 52.6 N medial; average r = 0.95 and RMSE = 56.6 N lateral). In contrast, Approach B overpredicted contact force magnitude for both compartments (average RMSE = 323 N medial and 348 N lateral) and poorly matched contact force shape for the lateral compartment (average r = 0.90 medial and −0.10 lateral). Approach B had statistically higher lateral muscle forces and lateral optimal muscle fiber lengths but lower medial, central, and lateral normalized muscle fiber lengths compared to Approach A. These findings suggest that poorly calibrated model parameter values may be a major factor limiting the ability of neuromusculoskeletal models to predict knee contact and leg muscle forces accurately for walking. PMID:27210105
Knee and Ankle Joint Angles Influence the Plantarflexion Torque of the Gastrocnemius.
Landin, Dennis; Thompson, Melissa; Reid, Meghan
2015-08-01
The gastrocnemius (GA) is the lone bi-articular muscle of the leg, crossing both the knee and ankle. As with any bi-articular muscle, both joints affect its length/tension curve. The role of the GA as a plantarflexor is firmly established; however, no current research has investigated how changes in knee and ankle joint positions on its ability to generate a plantarflexion (PF) torque. This paper reports on the PF force generated by the GA at specific knee and ankle joint combinations. The right GA of 26 participants was electrically stimulated via surface electrodes following a standardized protocol at 24 knee and ankle joint combinations. Three stimulations were applied at each of the 24 positions. Data were recorded on three dependent measures: the passive moment, which was the PF moment created by the tissue without stimulation, the maximum moment, which was the highest PF moment during the stimulation and included the passive moment, and the stimulated moment, which reflected the PF moment during stimulation minus the passive moment. A straight knee and dorsiflexed ankle create the position in which the GA generates the greatest PF moment, but it is also the position of greatest length. This finding is in contrast to conclusions from previous research with bi-articular muscles, which has consistently shown that the greatest length is not a muscle's optimal length. The full ranges of motion for the knee and ankle apparently do not elongate the GA beyond its optimal length for producing a PF moment. Clinicians commonly evaluate GA status with the patient seated and the foot subject to gravity. The present results indicate that manual testing of the GA in isolation should be performed, whenever possible, with the knee extended and the ankle dorsiflexed to potentially elicit the maximum PF torque from the GA.
Nyland, John; Jakob, Roland
2013-10-18
Knee function preservation following a diagnosis of osteoarthritis may benefit from healthy patient lifestyles, exercise or activity habits, and daily living routines. Underlying societal issues and social roles may contribute further to both ecological and knee function preservation concerns. Based on sustainability theory and social ecology concepts we propose that factors such as health history, genetic predisposition, socio-environmental factors and local-regional-global physiological system viability contribute to knee function preservation. Addressing only some of these factors or any one factor in isolation can lead the treating physician, surgeon and rehabilitation clinician to less than optimal treatment effectiveness. An example is presented of a 57-year-old man with medial tibiofemoral osteoarthritis. In the intervention decision-making process several factors are important. Patients who would benefit from early knee arthroplasty tend to place osteoarthritic knee pain elimination at the top of their list of treatment expectations. They also have minimal or no desire to continue impact sport, recreational or vocational activities. In contrast, patients who are good candidates for a knee function preservation treatment approach tend to have greater expectations to be able to continue impact sport, recreational or vocational activities, are willing and better able to implement significant behavioral changes and develop the support systems needed for their maintenance, are willing to tolerate and live with minor-to-moderate intermittent knee pain, and learn to become more pain tolerant.
Anand, T S; Sujatha, S
2017-08-01
Polycentric knees for transfemoral prostheses have a variety of geometries, but a survey of literature shows that there are few ways of comparing their performance. Our objective was to present a method for performance comparison of polycentric knee geometries and design a new geometry. In this work, we define parameters to compare various commercially available prosthetic knees in terms of their stability, toe clearance, maximum flexion, and so on and optimize the parameters to obtain a new knee design. We use the defined parameters and optimization to design a new knee geometry that provides the greater stability and toe clearance necessary to navigate uneven terrain which is typically encountered in developing countries. Several commercial knees were compared based on the defined parameters to determine their suitability for uneven terrain. A new knee was designed based on optimization of these parameters. Preliminary user testing indicates that the new knee is very stable and easy to use. The methodology can be used for better knee selection and design of more customized knee geometries. Clinical relevance The method provides a tool to aid in the selection and design of polycentric knees for transfemoral prostheses.
Yokosawa, Kenta; Sasaki, Kana; Muramatsu, Koichi; Ono, Tomoya; Izawa, Hiroyuki; Hachiya, Yudo
2016-05-01
Anterolateral ligament (ALL) is one of the lateral structures in the knee that contributes to the internal rotational stability of tibia. ALL has been referred to in some recent reports to re-emphasize its importance. We visualized the ALL on 3D-MRI in 32 knees of 27 healthy volunteers (23 male knees, 4 female knees; mean age: 37 years). 3D-MRIs were performed using 1.5-T scanner [T(2) weighted image (WI), SPACE: Sampling Perfection with Application optimized Contrast using different flip angle Evolutions] in the knee extended positions. The visualization rate of the ALL, the mean angle to the lateral collateral ligament (LCL), and the width and the thickness of the ALL at the joint level were investigated. The visualization rate was 100%. The mean angle to the LCL was 10.6 degrees. The mean width and the mean thickness of the ALL were 6.4 mm and 1.0 mm, respectively. The ALL is a very thin ligament with a somewhat oblique course between the lateral femoral epicondyle and the mid-third area of lateral tibial condyle. Therefore, the slice thickness and the slice angle can easily affect the ALL visualization. 3D-MRI enables acquiring thin-slice imaging data over a relatively short time, and arbitrary sections aligned with the course of the ALL can later be selected.
Perruccio, Anthony V; Gandhi, Rajiv; Lau, Johnny T C; Syed, Khalid A; Mahomed, Nizar N; Rampersaud, Y Raja
2016-01-01
Improving health-related quality of life (HRQoL) necessitates an understanding of the influence of patient characteristics on, and interrelationship among, HRQoL domains. In osteoarthritis (OA), these associations have predominantly been examined in hip/knee populations. We investigated whether there were differences in these associations between foot/ankle and knee OA samples. Individuals seeking orthopedic care for foot/ankle or knee OA completed a questionnaire pre-consultation, including HRQoL domains (bodily pain [BP], physical [PF] and social functioning [SF], and mental [MH] and general health [GH]), obesity, comorbidity, and sociodemographic characteristics. Associations were examined via stratified path analysis (foot/ankle vs knee). Foot/ankle: n = 180, mean age = 55 (range: 25 to 82), 52% female. Knee: n = 253, mean age = 62 (range: 26 to 92), 51% female. The interrelationship among HRQoL domains was generally similar between groups. However, the influence of patient characteristics differed. Low educational status was associated with worse scores for GH, MH, and SF in the foot/ankle group, whereas no significant effects were found in the knee group. Obesity was associated with worse scores for SF, BP, and GH in the foot/ankle compared to the knee group. Patient characteristics explained considerably more of the variation in domain scores in the foot/ankle group. There are significant differences in the impact of patient characteristics on HRQoL domains in foot/ankle versus knee OA patients. Therefore, a universal approach to patient education/intervention to improve HRQoL in lower-extremity OA is not likely to achieve optimal results. Based on these findings, we recommend joint-specific patient education, with a particular emphasis on patient characteristics among the foot/ankle OA population. Level III, retrospective comparative study. © The Author(s) 2015.
Narang, Yashraj S; Murthy Arelekatti, V N; Winter, Amos G
2016-12-01
Our research aims to design low-cost, high-performance, passive prosthetic knees for developing countries. In this study, we determine optimal stiffness, damping, and engagement parameters for a low-cost, passive prosthetic knee that consists of simple mechanical elements and may enable users to walk with the normative kinematics of able-bodied humans. Knee joint power was analyzed to divide gait into energy-based phases and select mechanical components for each phase. The behavior of each component was described with a polynomial function, and the coefficients and polynomial order of each function were optimized to reproduce the knee moments required for normative kinematics of able-bodied humans. Sensitivity of coefficients to prosthesis mass was also investigated. The knee moments required for prosthesis users to walk with able-bodied normative kinematics were accurately reproduced with a mechanical system consisting of a linear spring, two constant-friction dampers, and three clutches (R2=0.90 for a typical prosthetic leg). Alterations in upper leg, lower leg, and foot mass had a large influence on optimal coefficients, changing damping coefficients by up to 180%. Critical results are reported through parametric illustrations that can be used by designers of prostheses to select optimal components for a prosthetic knee based on the inertial properties of the amputee and his or her prosthetic leg.
Optimal design of a magnetorheological damper used in smart prosthetic knees
NASA Astrophysics Data System (ADS)
Gao, Fei; Liu, Yan-Nan; Liao, Wei-Hsin
2017-03-01
In this paper, a magnetorheological (MR) damper is optimally designed for use in smart prosthetic knees. The objective of optimization is to minimize the total energy consumption during one gait cycle and weight of the MR damper. Firstly, a smart prosthetic knee employing a DC motor, MR damper and springs is developed based on the kinetics characteristics of human knee during walking. Then the function of the MR damper is analyzed. In the initial stance phase and swing phase, the MR damper is powered off (off-state). While during the late stance phase, the MR damper is powered on to work as a clutch (on-state). Based on the MR damper model as well as the prosthetic knee model, the instantaneous energy consumption of the MR damper is derived in the two working states. Then by integrating in one gait cycle, the total energy consumption is obtained. Particle swarm optimization algorithm is used to optimize the geometric dimensions of MR damper. Finally, a prototype of the optimized MR damper is fabricated and tested with comparison to simulation.
Adaptation of NASA technology for the optimization of orthopedic knee implants
NASA Technical Reports Server (NTRS)
Saravanos, D. A.; Mraz, P. J.; Hopkins, D. A.
1991-01-01
The NASA technology originally developed for the optimization of composite structures (engine blades) is adapted and applied to the optimization of orthopedic knee implants. A method is developed enabling the tailoring of the implant for optimal interaction with the environment of the tibia. The shape of the implant components are optimized, such that the stresses in the bone are favorably controlled to minimize bone degradation and prevent failures. A pilot tailoring system is developed and the feasibility of the concept is elevated. The optimization system is expected to provide the means for improving knee prosthesis and individual implant tailoring for each patient.
Clément, Julien; Dumas, Raphaël; Hagemeister, Nicola; de Guise, Jaques A
2015-11-05
Soft tissue artifact (STA) distort marker-based knee kinematics measures and make them difficult to use in clinical practice. None of the current methods designed to compensate for STA is suitable, but multi-body optimization (MBO) has demonstrated encouraging results and can be improved. The goal of this study was to develop and validate the performance of knee joint models, with anatomical and subject-specific kinematic constraints, used in MBO to reduce STA errors. Twenty subjects were recruited: 10 healthy and 10 osteoarthritis (OA) subjects. Subject-specific knee joint models were evaluated by comparing dynamic knee kinematics recorded by a motion capture system (KneeKG™) and optimized with MBO to quasi-static knee kinematics measured by a low-dose, upright, biplanar radiographic imaging system (EOS(®)). Errors due to STA ranged from 1.6° to 22.4° for knee rotations and from 0.8 mm to 14.9 mm for knee displacements in healthy and OA subjects. Subject-specific knee joint models were most effective in compensating for STA in terms of abduction-adduction, inter-external rotation and antero-posterior displacement. Root mean square errors with subject-specific knee joint models ranged from 2.2±1.2° to 6.0±3.9° for knee rotations and from 2.4±1.1 mm to 4.3±2.4 mm for knee displacements in healthy and OA subjects, respectively. Our study shows that MBO can be improved with subject-specific knee joint models, and that the quality of the motion capture calibration is critical. Future investigations should focus on more refined knee joint models to reproduce specific OA knee geometry and physiology. Copyright © 2015 Elsevier Ltd. All rights reserved.
Sauer, Alexander; Li, Mengxia; Holl-Wieden, Annette; Pabst, Thomas; Neubauer, Henning
2017-10-12
Diffusion-weighted MRI has been proposed as a new technique for imaging synovitis without intravenous contrast application. We investigated diagnostic utility of multi-shot readout-segmented diffusion-weighted MRI (multi-shot DWI) for synovial imaging of the knee joint in patients with juvenile idiopathic arthritis (JIA). Thirty-two consecutive patients with confirmed or suspected JIA (21 girls, median age 13 years) underwent routine 1.5 T MRI with contrast-enhanced T1w imaging (contrast-enhanced MRI) and with multi-shot DWI (RESOLVE, b-values 0-50 and 800 s/mm 2 ). Contrast-enhanced MRI, representing the diagnostic standard, and diffusion-weighted images at b = 800 s/mm 2 were separately rated by three independent blinded readers at different levels of expertise for the presence and the degree of synovitis on a modified 5-item Likert scale along with the level of subjective diagnostic confidence. Fourteen (44%) patients had active synovitis and joint effusion, nine (28%) patients showed mild synovial enhancement not qualifying for arthritis and another nine (28%) patients had no synovial signal alterations on contrast-enhanced imaging. Ratings by the 1st reader on contrast-enhanced MRI and on DWI showed substantial agreement (κ = 0.74). Inter-observer-agreement was high for diagnosing, or ruling out, active arthritis of the knee joint on contrast-enhanced MRI and on DWI, showing full agreement between 1st and 2nd reader and disagreement in one case (3%) between 1st and 3rd reader. In contrast, ratings in cases of absent vs. little synovial inflammation were markedly inconsistent on DWI. Diagnostic confidence was lower on DWI, compared to contrast-enhanced imaging. Multi-shot DWI of the knee joint is feasible in routine imaging and reliably diagnoses, or rules out, active arthritis of the knee joint in paediatric patients without the need of gadolinium-based i.v. contrast injection. Possibly due to "T2w shine-through" artifacts, DWI does not reliably differentiate non-inflamed joints from knee joints with mild synovial irritation.
Colen, David L; Carney, Martin J; Shubinets, Valeriy; Lanni, Michael A; Liu, Tiffany; Levin, L Scott; Lee, Gwo-Chin; Kovach, Stephen J
2018-04-01
Total knee arthroplasty is a common orthopedic procedure in the United States and complications can be devastating. Soft-tissue compromise or joint infection may cause failure of prosthesis requiring knee fusion or amputation. The role of a plastic surgeon in total knee arthroplasty is critical for cases requiring optimization of the soft-tissue envelope. The purpose of this study was to elucidate factors associated with total knee arthroplasty salvage following complications and clarify principles of reconstruction to optimize outcomes. A retrospective review of patients requiring soft-tissue reconstruction performed by the senior author after total knee arthroplasty over 8 years was completed. Logistic regression and Fisher's exact tests determined factors associated with the primary outcome, prosthesis salvage versus knee fusion or amputation. Seventy-three knees in 71 patients required soft-tissue reconstruction (mean follow-up, 1.8 years), with a salvage rate of 61.1 percent, mostly using medial gastrocnemius flaps. Patients referred to our institution with complicated periprosthetic wounds were significantly more likely to lose their knee prosthesis than patients treated only within our system. Patients with multiple prior knee operations before definitive soft-tissue reconstruction had significantly decreased rates of prosthesis salvage and an increased risk of amputation. Knee salvage significantly decreased with positive joint cultures (Gram-negative greater than Gram-positive organisms) and particularly at the time of definitive reconstruction, which also trended toward an increased risk of amputation. In revision total knee arthroplasty, prompt soft-tissue reconstruction improves the likelihood of success, and protracted surgical courses and contamination increase failure and amputations. The authors show a benefit to involving plastic surgeons early in the course of total knee arthroplasty complications to optimize genicular soft tissues. Therapeutic, III.
Knee point search using cascading top-k sorting with minimized time complexity.
Wang, Zheng; Tseng, Shian-Shyong
2013-01-01
Anomaly detection systems and many other applications are frequently confronted with the problem of finding the largest knee point in the sorted curve for a set of unsorted points. This paper proposes an efficient knee point search algorithm with minimized time complexity using the cascading top-k sorting when a priori probability distribution of the knee point is known. First, a top-k sort algorithm is proposed based on a quicksort variation. We divide the knee point search problem into multiple steps. And in each step an optimization problem of the selection number k is solved, where the objective function is defined as the expected time cost. Because the expected time cost in one step is dependent on that of the afterwards steps, we simplify the optimization problem by minimizing the maximum expected time cost. The posterior probability of the largest knee point distribution and the other parameters are updated before solving the optimization problem in each step. An example of source detection of DNS DoS flooding attacks is provided to illustrate the applications of the proposed algorithm.
Agonist-antagonist active knee prosthesis: a preliminary study in level-ground walking.
Martinez-Villalpando, Ernesto C; Herr, Hugh
2009-01-01
We present a powered knee prosthesis with two series-elastic actuators positioned in parallel in an agonist-antagonist arrangement. To motivate the knee's design, we developed a prosthetic knee model that comprises a variable damper and two series-elastic clutch units that span the knee joint. Using human gait data to constrain the model's joint to move biologically, we varied model parameters using an optimization scheme that minimized the sum over time of the squared difference between the model's joint torque and biological knee values. We then used these optimized values to specify the mechanical and control design of the prosthesis for level-ground walking. We hypothesized that a variable-impedance control design could produce humanlike knee mechanics during steady-state level-ground walking. As a preliminary evaluation of this hypothesis, we compared the prosthetic knee mechanics of an amputee walking at a self-selected gait speed with those of a weight- and height-matched nonamputee. We found qualitative agreement between prosthetic and human knee mechanics. Because the knee's motors never perform positive work on the knee joint throughout the level-ground gait cycle, the knee's electrical power requirement is modest in walking (8 W), decreasing the size of the onboard battery required to power the prosthesis.
Segmentation of knee MRI using structure enhanced local phase filtering
NASA Astrophysics Data System (ADS)
Lim, Mikhiel; Hacihaliloglu, Ilker
2016-03-01
The segmentation of bone surfaces from magnetic resonance imaging (MRI) data has applications in the quanti- tative measurement of knee osteoarthritis, surgery planning for patient specific total knee arthroplasty and its subsequent fabrication of artificial implants. However, due to the problems associated with MRI imaging such as low contrast between bone and surrounding tissues, noise, bias fields, and the partial volume effect, segmentation of bone surfaces continues to be a challenging operation. In this paper, a new framework is presented for the enhancement of knee MRI scans prior to segmentation in order to obtain high contrast bone images. During the first stage, a new contrast enhanced relative total variation (RTV) regularization method is used in order to remove textural noise from the bone structures and surrounding soft tissue interface. This salient bone edge information is further enhanced using a sparse gradient counting method based on L0 gradient minimization, which globally controls how many non-zero gradients are resulted in order to approximate prominent bone structures in a structure-sparsity-management manner. The last stage of the framework involves incorporation of local phase bone boundary information in order to provide an intensity invariant enhancement of contrast between the bone and surrounding soft tissue. The enhanced images are segmented using a fast random walker algorithm. Validation against expert segmentation was performed on 10 clinical knee MRI images, and achieved a mean dice similarity coefficient (DSC) of 0.975.
Practical approach to subject-specific estimation of knee joint contact force.
Knarr, Brian A; Higginson, Jill S
2015-08-20
Compressive forces experienced at the knee can significantly contribute to cartilage degeneration. Musculoskeletal models enable predictions of the internal forces experienced at the knee, but validation is often not possible, as experimental data detailing loading at the knee joint is limited. Recently available data reporting compressive knee force through direct measurement using instrumented total knee replacements offer a unique opportunity to evaluate the accuracy of models. Previous studies have highlighted the importance of subject-specificity in increasing the accuracy of model predictions; however, these techniques may be unrealistic outside of a research setting. Therefore, the goal of our work was to identify a practical approach for accurate prediction of tibiofemoral knee contact force (KCF). Four methods for prediction of knee contact force were compared: (1) standard static optimization, (2) uniform muscle coordination weighting, (3) subject-specific muscle coordination weighting and (4) subject-specific strength adjustments. Walking trials for three subjects with instrumented knee replacements were used to evaluate the accuracy of model predictions. Predictions utilizing subject-specific muscle coordination weighting yielded the best agreement with experimental data; however this method required in vivo data for weighting factor calibration. Including subject-specific strength adjustments improved models' predictions compared to standard static optimization, with errors in peak KCF less than 0.5 body weight for all subjects. Overall, combining clinical assessments of muscle strength with standard tools available in the OpenSim software package, such as inverse kinematics and static optimization, appears to be a practical method for predicting joint contact force that can be implemented for many applications. Copyright © 2015 Elsevier Ltd. All rights reserved.
Practical approach to subject-specific estimation of knee joint contact force
Knarr, Brian A.; Higginson, Jill S.
2015-01-01
Compressive forces experienced at the knee can significantly contribute to cartilage degeneration. Musculoskeletal models enable predictions of the internal forces experienced at the knee, but validation is often not possible, as experimental data detailing loading at the knee joint is limited. Recently available data reporting compressive knee force through direct measurement using instrumented total knee replacements offer a unique opportunity to evaluate the accuracy of models. Previous studies have highlighted the importance of subject-specificity in increasing the accuracy of model predictions; however, these techniques may be unrealistic outside of a research setting. Therefore, the goal of our work was to identify a practical approach for accurate prediction of tibiofemoral knee contact force (KCF). Four methods for prediction of knee contact force were compared: (1) standard static optimization, (2) uniform muscle coordination weighting, (3) subject-specific muscle coordination weighting and (4) subject-specific strength adjustments. Walking trials for three subjects with instrumented knee replacements were used to evaluate the accuracy of model predictions. Predictions utilizing subject-specific muscle coordination weighting yielded the best agreement with experimental data, however this method required in vivo data for weighting factor calibration. Including subject-specific strength adjustments improved models’ predictions compared to standard static optimization, with errors in peak KCF less than 0.5 body weight for all subjects. Overall, combining clinical assessments of muscle strength with standard tools available in the OpenSim software package, such as inverse kinematics and static optimization, appears to be a practical method for predicting joint contact force that can be implemented for many applications. PMID:25952546
Palsis, John A; Brehmer, Thomas S; Pellegrini, Vincent D; Drew, Jacob M; Sachs, Barton L
2018-02-21
In an era of mandatory bundled payments for total joint replacement, accurate analysis of the cost of procedures is essential for orthopaedic surgeons and their institutions to maintain viable practices. The purpose of this study was to compare traditional accounting and time-driven activity-based costing (TDABC) methods for estimating the total costs of total hip and knee arthroplasty care cycles. We calculated the overall costs of elective primary total hip and total knee replacement care cycles at our academic medical center using traditional and TDABC accounting methods. We compared the methods with respect to the overall costs of hip and knee replacement and the costs for each major cost category. The traditional accounting method resulted in higher cost estimates. The total cost per hip replacement was $22,076 (2014 USD) using traditional accounting and was $12,957 using TDABC. The total cost per knee replacement was $29,488 using traditional accounting and was $16,981 using TDABC. With respect to cost categories, estimates using traditional accounting were greater for hip and knee replacement, respectively, by $3,432 and $5,486 for personnel, by $3,398 and $3,664 for space and equipment, and by $2,289 and $3,357 for indirect costs. Implants and consumables were derived from the actual hospital purchase price; accordingly, both methods produced equivalent results. Substantial cost differences exist between accounting methods. The focus of TDABC only on resources used directly by the patient contrasts with the allocation of all operating costs, including all indirect costs and unused capacity, with traditional accounting. We expect that the true costs of hip and knee replacement care cycles are likely somewhere between estimates derived from traditional accounting methods and TDABC. TDABC offers patient-level granular cost information that better serves in the redesign of care pathways and may lead to more strategic resource-allocation decisions to optimize actual operating margins.
Fey, Nicholas P; Klute, Glenn K; Neptune, Richard R
2012-11-01
Unilateral below-knee amputees develop abnormal gait characteristics that include bilateral asymmetries and an elevated metabolic cost relative to non-amputees. In addition, long-term prosthesis use has been linked to an increased prevalence of joint pain and osteoarthritis in the intact leg knee. To improve amputee mobility, prosthetic feet that utilize elastic energy storage and return (ESAR) have been designed, which perform important biomechanical functions such as providing body support and forward propulsion. However, the prescription of appropriate design characteristics (e.g., stiffness) is not well-defined since its influence on foot function and important in vivo biomechanical quantities such as metabolic cost and joint loading remain unclear. The design of feet that improve these quantities could provide considerable advancements in amputee care. Therefore, the purpose of this study was to couple design optimization with dynamic simulations of amputee walking to identify the optimal foot stiffness that minimizes metabolic cost and intact knee joint loading. A musculoskeletal model and distributed stiffness ESAR prosthetic foot model were developed to generate muscle-actuated forward dynamics simulations of amputee walking. Dynamic optimization was used to solve for the optimal muscle excitation patterns and foot stiffness profile that produced simulations that tracked experimental amputee walking data while minimizing metabolic cost and intact leg internal knee contact forces. Muscle and foot function were evaluated by calculating their contributions to the important walking subtasks of body support, forward propulsion and leg swing. The analyses showed that altering a nominal prosthetic foot stiffness distribution by stiffening the toe and mid-foot while making the ankle and heel less stiff improved ESAR foot performance by offloading the intact knee during early to mid-stance of the intact leg and reducing metabolic cost. The optimal design also provided moderate braking and body support during the first half of residual leg stance, while increasing the prosthesis contributions to forward propulsion and body support during the second half of residual leg stance. Future work will be directed at experimentally validating these results, which have important implications for future designs of prosthetic feet that could significantly improve amputee care.
Estimating patient-specific soft-tissue properties in a TKA knee.
Ewing, Joseph A; Kaufman, Michelle K; Hutter, Erin E; Granger, Jeffrey F; Beal, Matthew D; Piazza, Stephen J; Siston, Robert A
2016-03-01
Surgical technique is one factor that has been identified as critical to success of total knee arthroplasty. Researchers have shown that computer simulations can aid in determining how decisions in the operating room generally affect post-operative outcomes. However, to use simulations to make clinically relevant predictions about knee forces and motions for a specific total knee patient, patient-specific models are needed. This study introduces a methodology for estimating knee soft-tissue properties of an individual total knee patient. A custom surgical navigation system and stability device were used to measure the force-displacement relationship of the knee. Soft-tissue properties were estimated using a parameter optimization that matched simulated tibiofemoral kinematics with experimental tibiofemoral kinematics. Simulations using optimized ligament properties had an average root mean square error of 3.5° across all tests while simulations using generic ligament properties taken from literature had an average root mean square error of 8.4°. Specimens showed large variability among ligament properties regardless of similarities in prosthetic component alignment and measured knee laxity. These results demonstrate the importance of soft-tissue properties in determining knee stability, and suggest that to make clinically relevant predictions of post-operative knee motions and forces using computer simulations, patient-specific soft-tissue properties are needed. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Muscle Synergies May Improve Optimization Prediction of Knee Contact Forces During Walking
Walter, Jonathan P.; Kinney, Allison L.; Banks, Scott A.; D'Lima, Darryl D.; Besier, Thor F.; Lloyd, David G.; Fregly, Benjamin J.
2014-01-01
The ability to predict patient-specific joint contact and muscle forces accurately could improve the treatment of walking-related disorders. Muscle synergy analysis, which decomposes a large number of muscle electromyographic (EMG) signals into a small number of synergy control signals, could reduce the dimensionality and thus redundancy of the muscle and contact force prediction process. This study investigated whether use of subject-specific synergy controls can improve optimization prediction of knee contact forces during walking. To generate the predictions, we performed mixed dynamic muscle force optimizations (i.e., inverse skeletal dynamics with forward muscle activation and contraction dynamics) using data collected from a subject implanted with a force-measuring knee replacement. Twelve optimization problems (three cases with four subcases each) that minimized the sum of squares of muscle excitations were formulated to investigate how synergy controls affect knee contact force predictions. The three cases were: (1) Calibrate+Match where muscle model parameter values were calibrated and experimental knee contact forces were simultaneously matched, (2) Precalibrate+Predict where experimental knee contact forces were predicted using precalibrated muscle model parameters values from the first case, and (3) Calibrate+Predict where muscle model parameter values were calibrated and experimental knee contact forces were simultaneously predicted, all while matching inverse dynamic loads at the hip, knee, and ankle. The four subcases used either 44 independent controls or five synergy controls with and without EMG shape tracking. For the Calibrate+Match case, all four subcases closely reproduced the measured medial and lateral knee contact forces (R2 ≥ 0.94, root-mean-square (RMS) error < 66 N), indicating sufficient model fidelity for contact force prediction. For the Precalibrate+Predict and Calibrate+Predict cases, synergy controls yielded better contact force predictions (0.61 < R2 < 0.90, 83 N < RMS error < 161 N) than did independent controls (-0.15 < R2 < 0.79, 124 N < RMS error < 343 N) for corresponding subcases. For independent controls, contact force predictions improved when precalibrated model parameter values or EMG shape tracking was used. For synergy controls, contact force predictions were relatively insensitive to how model parameter values were calibrated, while EMG shape tracking made lateral (but not medial) contact force predictions worse. For the subject and optimization cost function analyzed in this study, use of subject-specific synergy controls improved the accuracy of knee contact force predictions, especially for lateral contact force when EMG shape tracking was omitted, and reduced prediction sensitivity to uncertainties in muscle model parameter values. PMID:24402438
Muscle synergies may improve optimization prediction of knee contact forces during walking.
Walter, Jonathan P; Kinney, Allison L; Banks, Scott A; D'Lima, Darryl D; Besier, Thor F; Lloyd, David G; Fregly, Benjamin J
2014-02-01
The ability to predict patient-specific joint contact and muscle forces accurately could improve the treatment of walking-related disorders. Muscle synergy analysis, which decomposes a large number of muscle electromyographic (EMG) signals into a small number of synergy control signals, could reduce the dimensionality and thus redundancy of the muscle and contact force prediction process. This study investigated whether use of subject-specific synergy controls can improve optimization prediction of knee contact forces during walking. To generate the predictions, we performed mixed dynamic muscle force optimizations (i.e., inverse skeletal dynamics with forward muscle activation and contraction dynamics) using data collected from a subject implanted with a force-measuring knee replacement. Twelve optimization problems (three cases with four subcases each) that minimized the sum of squares of muscle excitations were formulated to investigate how synergy controls affect knee contact force predictions. The three cases were: (1) Calibrate+Match where muscle model parameter values were calibrated and experimental knee contact forces were simultaneously matched, (2) Precalibrate+Predict where experimental knee contact forces were predicted using precalibrated muscle model parameters values from the first case, and (3) Calibrate+Predict where muscle model parameter values were calibrated and experimental knee contact forces were simultaneously predicted, all while matching inverse dynamic loads at the hip, knee, and ankle. The four subcases used either 44 independent controls or five synergy controls with and without EMG shape tracking. For the Calibrate+Match case, all four subcases closely reproduced the measured medial and lateral knee contact forces (R2 ≥ 0.94, root-mean-square (RMS) error < 66 N), indicating sufficient model fidelity for contact force prediction. For the Precalibrate+Predict and Calibrate+Predict cases, synergy controls yielded better contact force predictions (0.61 < R2 < 0.90, 83 N < RMS error < 161 N) than did independent controls (-0.15 < R2 < 0.79, 124 N < RMS error < 343 N) for corresponding subcases. For independent controls, contact force predictions improved when precalibrated model parameter values or EMG shape tracking was used. For synergy controls, contact force predictions were relatively insensitive to how model parameter values were calibrated, while EMG shape tracking made lateral (but not medial) contact force predictions worse. For the subject and optimization cost function analyzed in this study, use of subject-specific synergy controls improved the accuracy of knee contact force predictions, especially for lateral contact force when EMG shape tracking was omitted, and reduced prediction sensitivity to uncertainties in muscle model parameter values.
Wünschel, Markus; Wülker, Nikolaus; Müller, Otto
2013-11-01
Females have a higher risk in terms of anterior cruciate ligament injuries during sports than males. Reasons for this fact may be different anatomy and muscle recruitment patterns leading to less protection for the cruciate- and collateral-ligaments. This in vitro study aims to evaluate gender differences in knee joint kinematics and muscle force during weight-bearing knee flexions. Thirty-four human knee specimens (17 females/17 males) were mounted on a dynamic knee simulator. Weight-bearing single-leg knee flexions were performed with different amounts of simulated body weight (BW). Gender-specific kinematics was measured with an ultrasonic motion capture system and different loading conditions were examined. Knee joint kinematics did not show significant differences regarding anteroposterior and medial-lateral movement as well as tibial varus-valgus and internal-external rotation. This applied to all simulated amounts of BW. Simulating 100 N BW in contrast to AF50 led to a significant higher quadriceps overall force in female knees from 45° to 85° of flexion in contrast to BW 50 N. In these female specimens, the quadriceps overall force was about 20 % higher than in male knees being constant in higher flexion angles. It is indicated by our results that in a squatting movement females compared with males produce higher muscle forces, suggesting an increased demand for muscular stabilization, whereas tibio-femoral kinematics was similar for both genders.
Optimal design and control of an electromechanical transfemoral prosthesis with energy regeneration.
Rohani, Farbod; Richter, Hanz; van den Bogert, Antonie J
2017-01-01
In this paper, we present the design of an electromechanical above-knee active prosthesis with energy storage and regeneration. The system consists of geared knee and ankle motors, parallel springs for each motor, an ultracapacitor, and controllable four-quadrant power converters. The goal is to maximize the performance of the system by finding optimal controls and design parameters. A model of the system dynamics was developed, and used to solve a combined trajectory and design optimization problem. The objectives of the optimization were to minimize tracking error relative to human joint motions, as well as energy use. The optimization problem was solved by the method of direct collocation, based on joint torque and joint angle data from ten subjects walking at three speeds. After optimization of controls and design parameters, the simulated system could operate at zero energy cost while still closely emulating able-bodied gait. This was achieved by controlled energy transfer between knee and ankle, and by controlled storage and release of energy throughout the gait cycle. Optimal gear ratios and spring parameters were similar across subjects and walking speeds.
Contrast agent enhanced pQCT of articular cartilage
NASA Astrophysics Data System (ADS)
Kallioniemi, A. S.; Jurvelin, J. S.; Nieminen, M. T.; Lammi, M. J.; Töyräs, J.
2007-02-01
The delayed gadolinium enhanced MRI of cartilage (dGEMRIC) technique is the only non-invasive means to estimate proteoglycan (PG) content in articular cartilage. In dGEMRIC, the anionic paramagnetic contrast agent gadopentetate distributes in inverse relation to negatively charged PGs, leading to a linear relation between T1,Gd and spatial PG content in tissue. In the present study, for the first time, contrast agent enhanced peripheral quantitative computed tomography (pQCT) was applied, analogously to dGEMRIC, for the quantitative detection of spatial PG content in cartilage. The suitability of two anionic radiographic contrast agents, gadopentetate and ioxaglate, to detect enzymatically induced PG depletion in articular cartilage was investigated. First, the interrelationships of x-ray absorption, as measured with pQCT, and the contrast agent solution concentration were investigated. Optimal contrast agent concentrations for the following experiments were selected. Second, diffusion rates for both contrast agents were investigated in intact (n = 3) and trypsin-degraded (n = 3) bovine patellar cartilage. The contrast agent concentration of the cartilaginous layer was measured prior to and 2-27 h after immersion. Optimal immersion time for the further experiments was selected. Third, the suitability of gadopentetate and ioxaglate enhanced pQCT to detect the enzymatically induced specific PG depletion was investigated by determining the contrast agent concentrations and uronic acid and water contents in digested and intact osteochondral samples (n = 16). After trypsin-induced PG loss (-70%, p < 0.05) the penetration of gadopentetate and ioxaglate increased (p < 0.05) by 34% and 48%, respectively. Gadopentetate and ioxaglate concentrations both showed strong correlation (r = -0.95, r = -0.94, p < 0.01, respectively) with the uronic acid content. To conclude, contrast agent enhanced pQCT provides a technique to quantify PG content in normal and experimentally degraded articular cartilage in vitro. As high resolution imaging of e.g. the knee joint is possible with pQCT, the present technique may be further developed for in vivo quantification of PG depletion in osteoarthritic cartilage. However, careful in vitro and in vivo characterization of diffusion mechanics and optimal contrast agent concentrations are needed before diagnostic applications are feasible.
Kinematic comparison of the preferred and non-preferred foot punt kick.
Ball, Kevin A
2011-11-01
Kicking with the non-preferred leg is important in Australian Football and becoming important in the rugby codes. The aim of this study was to examine differences between preferred and non-preferred leg kicking in the drop punt kick. Seventeen elite Australian Football players performed kicks with the preferred and non-preferred leg. Optotrak Certus collected kinematic data of the kick leg and pelvis (200 Hz) from kick leg toe-off until ball contact. Foot speed, knee and shank angular velocity at ball contact, and pelvis range of motion were significantly larger for the preferred leg (P < 0.05). In contrast, hip and thigh angular velocity at ball contact and hip range of motion were significantly larger for the non-preferred leg. This indicates different movement patterns, with preferred-leg kicks making greater use of the pelvis, knee, and shank while non-preferred leg kicks rely relatively more on the hip and thigh (P < 0.05). Reasons for this difference might be due to locking degrees of freedom or sub-optimal sequencing in the non-preferred leg. The thigh-knee continuum identified by Ball ( 2008 ) was also evident in this study. Findings have implications for training non-preferred leg kicking for performance and injury prevention.
Bünger, C; Harving, S; Hjermind, J; Bünger, E H
1983-04-01
The influence of chronic synovial inflammation and effusion on the juxta-articular bone haemodynamics in the juvenile knee was studied in 12 immature dogs with Carragheenin-induced unilateral arthritis. Using a fluid filled electromanometric pressure recording system simultaneous pressure measurements were taken from the distal femoral metaphysis, juxta-articular epiphyses and knee joint cavity in general anaesthesia followed by intraosseous phlebographies. During resting conditions the intraosseous pressure of the distal femoral epiphysis and the intra-articular pressure was significantly elevated. The phlebographies showed increased accumulation of contrast in arthritic femoral epiphyses with decreased contrast clearance rate. During increasing intra-articular pressure an augmented vulnerability of the blood supply of the arthritic femoral epiphyses was demonstrated. The results suggests that joint effusion may play an important role in the bone changes in juvenile degenerative arthritis of the knee.
Clausen, Brian; Holsgaard-Larsen, Anders; Søndergaard, Jens; Christensen, Robin; Andriacchi, Thomas P; Roos, Ewa M
2014-11-15
Knee osteoarthritis (OA) is a mechanically driven disease, and it is suggested that medial tibiofemoral knee-joint load increases with pharmacologic pain relief, indicating that pharmacologic pain relief may be positively associated with disease progression. Treatment modalities that can both relieve pain and reduce knee-joint load would be preferable. The knee-joint load is influenced by functional alignment of the trunk, pelvis, and lower-limb segments with respect to the knee, as well as the ground-reaction force generated during movement. Neuromuscular exercise can influence knee load and decrease knee pain. It includes exercises to improve balance, muscle activation, functional alignment, and functional knee stability. The primary objective of this randomized controlled trial (RCT) is to investigate the efficacy of a NEuroMuscular EXercise (NEMEX) therapy program, compared with optimized analgesics and antiinflammatory drug use, on the measures of knee-joint load in people with mild to moderate medial tibiofemoral knee osteoarthritis. One hundred men and women with mild to moderate medial knee osteoarthritis will be recruited from general medical practices and randomly allocated (1:1) to one of two 8-week treatments, either (a) NEMEX therapy twice a week or (b) information on the recommended use of analgesics and antiinflammatory drugs (acetaminophen and oral NSAIDs) via a pamphlet and video materials. The primary outcome is change in knee load during walking (the Knee Index, a composite score of the first external peak total reaction moment on the knee joint from all three planes based on 3D movement analysis) after 8 weeks of intervention. Secondary outcomes include changes in the external peak knee-adduction moment and impulse and functional performance measures, in addition to changes in self-reported pain, function, health status, and quality of life. These findings will help determine whether 8 weeks of neuromuscular exercise is superior to optimized use of analgesics and antiinflammatory drugs regarding knee-joint load, pain and physical function in people with mild to moderate knee osteoarthritis. ClinicalTrials.gov Identifier: NCT01638962 (July 3, 2012).
Phanphet, Suwattanarwong; Dechjarern, Surangsee; Jomjanyong, Sermkiat
2017-05-01
The main objective of this work is to improve the standard of the existing design of knee prosthesis developed by Thailand's Prostheses Foundation of Her Royal Highness The Princess Mother. The experimental structural tests, based on the ISO 10328, of the existing design showed that a few components failed due to fatigue under normal cyclic loading below the required number of cycles. The finite element (FE) simulations of structural tests on the knee prosthesis were carried out. Fatigue life predictions of knee component materials were modeled based on the Morrow's approach. The fatigue life prediction based on the FE model result was validated with the corresponding structural test and the results agreed well. The new designs of the failed components were studied using the design of experimental approach and finite element analysis of the ISO 10328 structural test of knee prostheses under two separated loading cases. Under ultimate loading, knee prosthesis peak von Mises stress must be less than the yield strength of knee component's material and the total knee deflection must be lower than 2.5mm. The fatigue life prediction of all knee components must be higher than 3,000,000 cycles under normal cyclic loading. The design parameters are the thickness of joint bars, the diameter of lower connector and the thickness of absorber-stopper. The optimized knee prosthesis design meeting all the requirements was recommended. Experimental ISO 10328 structural test of the fabricated knee prosthesis based on the optimized design confirmed the finite element prediction. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
A survey of footwear advice, beliefs and wear habits in people with knee osteoarthritis.
Paterson, Kade L; Wrigley, Tim V; Bennell, Kim L; Hinman, Rana S
2014-01-01
Expert opinion recommends cushioned and supportive footwear for people with knee osteoarthritis (OA). However, little is known about the footwear advice people receive from healthcare professionals, or the beliefs and footwear habits of people with knee OA. This study aimed to determine i) what types of shoes people are advised to wear for their knee OA and by whom; ii) establish which types of shoes people with knee OA believe are best for managing their knee OA symptoms and (iii) which shoes they wear most often. 204 people with symptomatic knee OA completed an online survey. The survey comprised 14 questions asking what footwear advice people had received for their knee OA and who they received it from, individual beliefs about optimal footwear styles for their knee OA symptoms and the types of footwear usually worn. Only one third (n = 69, 34%) of participants reported receiving footwear advice for their knee OA, and this was most frequently received from a podiatrist (n = 47, 68%). The most common advice was to wear sturdy/supportive shoes (n = 96, 47%) or shoes with arch supports (n = 84, 41%). These were also amongst the shoe styles that participants believed were best for their knee OA (n = 157 (77%) and n = 138 (68%) respectively). The type of shoes most frequently worn were athletic (n = 131, 64%) and sturdy/supportive shoes (n = 116, 57%). Most people with knee OA who completed our survey had not received advice about footwear for their knee OA symptoms. Our participants typically believed that sturdy/supportive shoes were best for their knee OA and this shoe style was most frequently worn, which is reflective of expert opinion. Future research is needed to confirm whether sturdy/supportive shoes are indeed optimal for managing symptoms of knee OA.
Aggarwal, Aakanksha
2018-05-19
We totally agree with the statement of the authors of the letter to the editor that "the incidence of CRPS knee following trauma or otherwise is not well appreciated". We would like to refer to our earlier published paper in which we concluded that the scientific literature does report cases of CRPS type I of only the knee(s). Our recommendation was to consider CRPS confined to the knee as a medical entity and therefore to include CRPS of only the knee(s) in future research on the etiological mechanisms of and optimal treatment for CRPS [1]. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Kiriyama, Yoshimori; Matsumoto, Hideo; Toyama, Yoshiaki; Nagura, Takeo
2014-02-01
The aim of this study was to develop a new suture tension sensor for musculoskeletal soft tissue that shows deformation or movements. The suture tension sensor was 10 mm in size, which was small enough to avoid conflicting with the adjacent sensor. Furthermore, the sensor had good linearity up to a tension of 50 N, which is equivalent to the breaking strength of a size 1 absorbable suture defined by the United States Pharmacopeia. The design and mechanism were analyzed using a finite element model prior to developing the actual sensor. Based on the analysis, adequate material was selected, and the output linearity was confirmed and compared with the simulated result. To evaluate practical application, the incision of the skin and capsule were sutured during simulated total knee arthroplasty. When conventional surgery and minimally invasive surgery were performed, suture tensions were compared. In minimally invasive surgery, the distal portion of the knee was dissected, and the proximal portion of the knee was dissected additionally in conventional surgery. In the skin suturing, the maximum tension was 4.4 N, and this tension was independent of the sensor location. In contrast, the sensor suturing the capsule in the distal portion had a tension of 4.4 N in minimally invasive surgery, while the proximal sensor had a tension of 44 N in conventional surgery. The suture tensions increased nonlinearly and were dependent on the knee flexion angle. Furthermore, the tension changes showed hysteresis. This miniature tension sensor may help establish the optimal suturing method with adequate tension to ensure wound healing and early recovery.
Holm, Bente; Husted, Henrik; Kehlet, Henrik; Bandholm, Thomas
2012-08-01
To investigate the acute effect of knee joint icing on knee extension strength and knee pain in patients shortly after total knee arthroplasty. A prospective, single-blinded, randomized, cross-over study. A fast-track orthopaedic arthroplasty unit at a university hospital. Twenty patients (mean age 66 years; 10 women) scheduled for primary unilateral total knee arthroplasty. The patients were treated on two days (day 7 and day 10) postoperatively. On one day they received 30 minutes of knee icing (active treatment) and on the other day they received 30 minutes of elbow icing (control treatment). The order of treatments was randomized. Maximal knee extension strength (primary outcome), knee pain at rest and knee pain during the maximal knee extensions were measured 2-5 minutes before and 2-5 minutes after both treatments by an assessor blinded for active or control treatment. The change in knee extension strength associated with knee icing was not significantly different from that of elbow icing (knee icing change (mean (1 SD)) -0.01 (0.07) Nm/kg, elbow icing change -0.02 (0.07) Nm/kg, P = 0.493). Likewise, the changes in knee pain at rest (P = 0.475), or knee pain during the knee extension strength measurements (P = 0.422) were not different between treatments. In contrast to observations in experimental knee effusion models and inflamed knee joints, knee joint icing for 30 minutes shortly after total knee arthroplasty had no acute effect on knee extension strength or knee pain.
Design of patient-specific gait modifications for knee osteoarthritis rehabilitation.
Fregly, Benjamin J; Reinbolt, Jeffrey A; Rooney, Kelly L; Mitchell, Kim H; Chmielewski, Terese L
2007-09-01
Abstract-Gait modification is a nonsurgical approach for reducing the external knee adduction torque in patients with knee osteoarthritis (OA). The magnitude of the first adduction torque peak in particular is strongly associated with knee OA progression. While toeing out has been shown to reduce the second peak, no clinically realistic gait modifications have been identified that effectively reduce both peaks simultaneously. This study predicts novel patient-specific gait modifications that achieve this goal without changing the foot path. The modified gait motion was designed for a single patient with knee OA using dynamic optimization of a patient-specific, full-body gait model. The cost function minimized the knee adduction torque subject to constraints limiting how much the new gait motion could deviate from the patient's normal gait motion. The optimizations predicted a "medial-thrust" gait pattern that reduced the first adduction torque peak between 32% and 54% and the second peak between 34% and 56%. The new motion involved three synergistic kinematic changes: slightly decreased pelvis obliquity, slightly increased leg flexion, and slightly increased pelvis axial rotation. After gait retraining, the patient achieved adduction torque reductions of 39% to 50% in the first peak and 37% to 55% in the second one. These reductions are comparable to those reported after high tibial osteotomy surgery. The associated kinematic changes were consistent with the predictions except for pelvis obliquity, which showed little change. This study demonstrates that it is feasible to design novel patient-specific gait modifications with potential clinical benefit using dynamic optimization of patient-specific, full-body gait models. Further investigation is needed to assess the extent to which similar gait modifications may be effective for other patients with knee OA.
How does knee pain affect trunk and knee motion during badminton forehand lunges?
Huang, Ming-Tung; Lee, Hsing-Hsan; Lin, Cheng-Feng; Tsai, Yi-Ju; Liao, Jen-Chieh
2014-01-01
Badminton requires extensive lower extremity movement and a precise coordination of the upper extremity and trunk movements. Accordingly, this study investigated motions of the trunk and the knee, control of dynamic stability and muscle activation patterns of individuals with and without knee pain. Seventeen participants with chronic knee pain and 17 healthy participants participated in the study and performed forehand forward and backward diagonal lunges. This study showed that those with knee pain exhibited smaller knee motions in frontal and horizontal planes during forward lunge but greater knee motions in sagittal plane during backward lunge. By contrast, in both tasks, the injured group showed a smaller value on the activation level of the paraspinal muscles in pre-impact phase, hip-shoulder separation angle, trunk forward inclination range and peak centre of mass (COM) velocity. Badminton players with knee pain adopt a more conservative movement pattern of the knee to minimise recurrence of knee pain. The healthy group exhibit better weight-shifting ability due to a greater control of the trunk and knee muscles. Training programmes for badminton players with knee pain should be designed to improve both the neuromuscular control and muscle strength of the core muscles and the knee extensor with focus on the backward lunge motion.
Comparison of robot surgery modular and total knee arthroplasty kinematics.
Yildirim, Gokce; Fernandez-Madrid, Ivan; Schwarzkopf, Ran; Walker, Peter S; Karia, Raj
2014-04-01
The kinematics of seven knee specimens were measured from 0 to 120 degrees flexion using an up-and-down crouching machine. Motion was characterized by the positions of the centers of the lateral and medial femoral condyles in the anterior-posterior direction relative to a fixed tibia. A modular unicompartmental knee, trochlea flange, and patella resurfacing (multicompartmental knee [MCK] system) were implanted using a surgeon-interactive robot system that provided accurate surface matching. The MCK was tested, followed by standard cruciate retaining (CR) and posterior stabilized (PS) knees. The motion of the MCK was close to anatomic, especially on the medial side, in contrast to the CR and PS knees that showed abnormal motion features. Such a modular knee system, accurately inserted, has the potential for close to normal function in clinical application. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Traumatic Extra-capsular and Intra-capsular Floating Fat: Fat-fluid Levels of the Knee Revisited
Davis, Derik L; Vachhani, Prasann
2015-01-01
Floating fat is a sign of acute bone injury at the knee following trauma. The goal of this article is to review the etiology, patterns, and mimickers of extra-capsular and intra-capsular floating fat, with the major emphasis on knee trauma in the acute setting. We will discuss the spectrum of multimodal imaging findings for rare presentations of extra-capsular floating fat, and contrast these with common and atypical forms of intra-capsular lipohemarthrosis, as an aid to the assessment of acute bone trauma at the knee. PMID:26713176
Goulston, L M; Sanchez-Santos, M T; D'Angelo, S; Leyland, K M; Hart, D J; Spector, T D; Cooper, C; Dennison, E M; Hunter, D; Arden, N K
2016-04-01
Malalignment is associated with knee osteoarthritis (KOA), however, the optimal anatomic axis (AA) knee alignment measurement on a standard limb radiograph (SLR) is unknown. This study compares one-point (1P) and two-point (2P) AA methods using three knee joint centre locations and examines cross-sectional associations with symptomatic radiographic knee osteoarthritis (SRKOA), radiographic knee osteoarthritis (RKOA) and knee pain. AA alignment was measured six different ways using the KneeMorf software on 1058 SLRs from 584 women in the Chingford Study. Cross-sectional associations with principal outcome SRKOA combined with greatest reproducibility determined the optimal 1P and 2P AA method. Appropriate varus/neutral/valgus alignment categories were established using logistic regression with generalised estimating equation models fitted with restricted cubic spline function. The tibial plateau centre displayed greatest reproducibility and associations with SRKOA. As mean 1P and 2P values differed by >2°, new alignment categories were generated for 1P: varus <178°, neutral 178-182°, valgus >182° and for 2P methods: varus <180°, neutral 180-185°, valgus >185°. Varus vs neutral alignment was associated with a near 2-fold increase in SRKOA and RKOA, and valgus vs neutral for RKOA using 2P method. Nonsignificant associations were seen for 1P method for SRKOA, RKOA and knee pain. AA alignment was associated with SRKOA and the tibial plateau centre had the strongest association. Differences in AA alignment when 1P vs 2P methods were compared indicated bespoke alignment categories were necessary. Further replication and validation with mechanical axis alignment comparison is required. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.
Wied, Christian; Thomsen, Morten G; Kallemose, Thomas; Myhrmann, Lis; Jensen, Lotte S; Husted, Henrik; Troelsen, Anders
2015-10-01
Fast-track TKA has significantly shortened the time available for physiotherapists to optimize knee ROM before discharge. Safety aspects concerning knee stiffness and the need for manipulation in a fast-track setting need to be illuminated. The study aims were to analyze if fast-track TKA can be considered safe considering rates of knee manipulation and if there is an association between knee ROM at time of discharge and the need for later manipulation. Primary TKAs operated in 2011 at our institution were eligible for inclusion. The study group consisted of 359 TKAs. Manipulation of the knee was performed in 21 of 359 TKAs (5.8%). Seventy-one percent were discharged with a flexion ≥70° combined with an extension deficit of ≤10°. The occurrence of MUA for these patients was 4.3%. The prevalence of knee manipulation showed a statistically significant association with the achieved knee flexion at discharge (p=0.02). Median length of stay was two days. Compared with literature findings fast-track TKA surgery may be considered safe based on the acceptable rate of knee manipulations after TKA (5.8%). We suggest ROM of ≥70° flexion combined with an extension deficit of ≤10° as an "optimal-zone" for ROM at discharge. The reason for this is the low occurrence of MUA (4.3%) in relation to the large amount of TKAs it represents (71%). The indication for MUA is multifactorial and ROM at discharge serves only as an indicator of later MUA risk. Copyright © 2015 Elsevier B.V. All rights reserved.
Goulston, L.M.; Sanchez-Santos, M.T.; D'Angelo, S.; Leyland, K.M.; Hart, D.J.; Spector, T.D.; Cooper, C.; Dennison, E.M.; Hunter, D.; Arden, N.K.
2016-01-01
Summary Objective Malalignment is associated with knee osteoarthritis (KOA), however, the optimal anatomic axis (AA) knee alignment measurement on a standard limb radiograph (SLR) is unknown. This study compares one-point (1P) and two-point (2P) AA methods using three knee joint centre locations and examines cross-sectional associations with symptomatic radiographic knee osteoarthritis (SRKOA), radiographic knee osteoarthritis (RKOA) and knee pain. Methods AA alignment was measured six different ways using the KneeMorf software on 1058 SLRs from 584 women in the Chingford Study. Cross-sectional associations with principal outcome SRKOA combined with greatest reproducibility determined the optimal 1P and 2P AA method. Appropriate varus/neutral/valgus alignment categories were established using logistic regression with generalised estimating equation models fitted with restricted cubic spline function. Results The tibial plateau centre displayed greatest reproducibility and associations with SRKOA. As mean 1P and 2P values differed by >2°, new alignment categories were generated for 1P: varus <178°, neutral 178–182°, valgus >182° and for 2P methods: varus <180°, neutral 180–185°, valgus >185°. Varus vs neutral alignment was associated with a near 2-fold increase in SRKOA and RKOA, and valgus vs neutral for RKOA using 2P method. Nonsignificant associations were seen for 1P method for SRKOA, RKOA and knee pain. Conclusions AA alignment was associated with SRKOA and the tibial plateau centre had the strongest association. Differences in AA alignment when 1P vs 2P methods were compared indicated bespoke alignment categories were necessary. Further replication and validation with mechanical axis alignment comparison is required. PMID:26700504
MR Imaging of Knee Arthroplasty Implants
Fritz, Jan; Lurie, Brett
2015-01-01
Primary total knee arthroplasty is a highly effective treatment that relieves pain and improves joint function in a large percentage of patients. Despite an initially satisfactory surgical outcome, pain, dysfunction, and implant failure can occur over time. Identifying the etiology of complications is vital for appropriate management and proper timing of revision. Due to the increasing number of knee arthroplasties performed and decreasing patient age at implantation, there is a demand for accurate diagnosis to determine appropriate treatment of symptomatic joints following knee arthroplasty, and for monitoring of patients at risk. Magnetic resonance (MR) imaging allows for comprehensive imaging evaluation of the tissues surrounding knee arthroplasty implants with metallic components, including the polyethylene components. Optimized conventional and advanced pulse sequences can result in substantial metallic artifact reduction and afford improved visualization of bone, implant-tissue interfaces, and periprosthetic soft tissue for the diagnosis of arthroplasty-related complications. In this review article, we discuss strategies for MR imaging around knee arthroplasty implants and illustrate the imaging appearances of common modes of failure, including aseptic loosening, polyethylene wear–induced synovitis and osteolysis, periprosthetic joint infections, fracture, patellar clunk syndrome, recurrent hemarthrosis, arthrofibrosis, component malalignment, extensor mechanism injury, and instability. A systematic approach is provided for evaluation of MR imaging of knee implants. MR imaging with optimized conventional pulse sequences and advanced metal artifact reduction techniques can contribute important information for diagnosis, prognosis, risk stratification, and surgical planning. ©RSNA, 2015 PMID:26295591
Boguszewski, Daniel V; Wagner, Christopher T; Butler, David L; Shearn, Jason T
2015-12-01
This study determined how anterior cruciate ligament (ACL) reconstruction affected the magnitude and temporal patterns of anterior knee force and internal knee moment during 2000 cycles of simulated gait. Porcine knees were tested using a six degree-of-freedom robot, examining three porcine allograft materials compared with the native ACL. Reconstructions were performed using: (1) bone-patellar tendon-bone allograft (BPTB), (2) reconstructive porcine tissue matrix (RTM), or (3) an RTM-polymer hybrid construct (Hybrid). Forces and moments were measured over the entire gait cycle and contrasted at heel strike, mid stance, toe off, and peak flexion. The Hybrid construct performed the best, as magnitude and temporal changes in both anterior knee force and internal knee moment were not different from the native ACL knee. Conversely, the RTM knees showed greater loss in anterior knee force during 2000 cycles than the native ACL knee at heel strike and toe off, with an average force loss of 46%. BPTB knees performed the least favorably, with significant loss in anterior knee force at all key points and an average force loss of 61%. This is clinically relevant, as increases in post-operative knee laxity are believed to play a role in graft failure and early onset osteoarthritis. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Design and Evaluation of a Prosthetic Knee Joint Using the Geared Five-Bar Mechanism.
Sun, Yuanxi; Ge, Wenjie; Zheng, Jia; Dong, Dianbiao
2015-11-01
This paper presents the mechanical design, dynamics analysis and ankle trajectory analysis of a prosthetic knee joint using the geared five-bar mechanism. Compared with traditional four-bar or six-bar mechanisms, the geared five-bar mechanism is better at performing diverse movements and is easy to control. This prosthetic knee joint with the geared five-bar mechanism is capable of fine-tuning its relative instantaneous center of rotation and ankle trajectory. The centrode of this prosthetic knee joint, which is mechanically optimized according to the centrode of human knee joint, is better in the bionic performance than that of a prosthetic knee joint using the four-bar mechanism. Additionally, the stability control of this prosthetic knee joint during the swing and stance phase is achieved by a motor. By adjusting the gear ratio of this prosthetic knee joint, the ankle trajectories of both unilateral and bilateral amputees show less deviations from expected than that of the four-bar knee joint.
Wei, Wenbo; Lambach, Becky; Jia, Guang; Flanigan, David; Chaudhari, Ajit M W; Wei, Lai; Rogers, Alan; Payne, Jason; Siston, Robert A; Knopp, Michael V
2017-06-01
The prevalence of cartilage lesions is much higher in football athletes than in the general population. Delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) has been shown to quantify regional variations of glycosaminoglycan (GAG) concentrations which is an indicator of early cartilage degeneration. The goal of this study is to determine whether dGEMRIC can be used to assess the influence in cartilage GAG concentration due to college level football play. Thirteen collegiate football players with one to four years of collegiate football play experience were recruited and both knee joints were scanned using a dedicated 8-channel phased array knee coil on a 3T MRI system. The contrast concentrations within cartilage were calculated based on the T 1 values from dGEMRIC scans. No substantial differences were found in the contrast concentrations between the pre- and post-season across all the cartilage compartments. One year collegiate football players presented an average contrast concentration at the pre-season of 0.116±0.011mM and post-season of 0.116±0.011mM. In players with multiple years of football play, contrast uptake was elevated to 0.141±0.012mM at the pre-season and 0.139±0.012mM at the post-season. The pre-season 0.023±0.016mM and post-season 0.025±0.016mM increase in contrast concentration within the group with multiple years of experience presented with a >20% increase in contrast uptake. This may indicate the gradual, cumulative damage of football play to the articular cartilage over years, even though the effect may not be noticeable after a season of play. Playing collegiate football for a longer period of time may lead to cartilage microstructural alterations, which may be linked to early knee cartilage degeneration. Copyright © 2017 Elsevier Inc. All rights reserved.
Shetty, Gautam M; Mullaji, Arun; Bhayde, Sagar
2012-10-01
This prospective study aimed to evaluate radiographically, change in joint line and femoral condylar offset with the optimized gap balancing technique in computer-assisted, primary, cruciate-substituting total knee arthroplasties (TKAs). One hundred and twenty-nine consecutive computer-assisted TKAs were evaluated radiographically using pre- and postoperative full-length standing hip-to-ankle, antero-posterior and lateral radiographs to assess change in knee deformity, joint line height and posterior condylar offset. In 49% of knees, there was a net decrease (mean 2.2mm, range 0.2-8.4mm) in joint line height postoperatively whereas 46.5% of knees had a net increase in joint line height (mean 2.5mm, range 0.2-11.2mm). In 93% of the knees, joint line was restored to within ± 5 mm of preoperative values. In 53% of knees, there was a net increase (mean 2.9 mm, range 0.2-12 mm) in posterior offset postoperatively whereas 40% of knees had a net decrease in posterior offset (mean 4.2mm, range 0.6-20mm). In 82% of knees, the posterior offset was restored within ± 5 mm of preoperative values. Based on radiographic evaluation in extension and at 30° flexion, the current study clearly demonstrates that joint line and posterior femoral condylar offset can be restored in the majority of computer-assisted, cruciate-substituting TKAs to within 5mm of their preoperative value. The optimized gap balancing feature of the computer software allows the surgeon to simulate the effect of simultaneously adjusting femoral component size, position and distal femoral resection level on joint line and posterior femoral offset. Copyright © 2011 Elsevier B.V. All rights reserved.
Riis, Robert G C; Gudbergsen, Henrik; Henriksen, Marius; Ballegaard, Christine; Bandak, Elisabeth; Röttger, Diana; Bliddal, Henning; Hansen, Bjarke Brandt; Hangaard, Stine; Boesen, Mikael
2016-06-01
To investigate the association between pain and peripatellar-synovitis on static and dynamic contrast-enhanced MRI in knee osteoarthritis. In a cross-sectional setting, knee synovitis was assessed using 3-Tesla MRI and correlated with pain using the knee injury and osteoarthritis outcome score (KOOS). Synovitis was assessed in the peripatellar recesses with: (i) dynamic contrast-enhanced (DCE)-MRI, using both pharmacokinetic and heuristic models, (ii) contrast-enhanced (CE)-MRI, and (iii) non-CE-MRI. The DCE-MRI variable IRExNvoxel was chosen as the primary variable in the analyses. Valid data were available in 94 persons with a mean age of 65 years, a BMI of 32.3kg/m(2) and a mean Kellgren-Lawrence grade of 2.5. IRExNvoxel showed a statically significant correlation with KOOS-Pain (r=-0.34; p=0.001), as was the case with all DCE-variables but one. Correlations between static MRI-variables and KOOS-Pain ranged between -0.21
Lutterbey, G; Behrends, K; Falkenhausen, M V; Wattjes, M P; Morakkabati, N; Gieseke, J; Schild, H
2007-02-01
The purpose of this study was to compare the in-built body coil of the 3.0-Tesla (T) scanner with a dedicated surface coil of a 1.5 T system regarding knee imaging. We performed an intraindividual prospective clinical trial on 17 patients with knee pain using magnetic resonance imaging (MRI) at 1.5 and 3.0 T systems equipped with identical gradient systems. Proton-density-weighted turbo spin echo sequences with the same spatial resolution and comparable contrast parameters were used. A quantitative measurement of signal to noise ratio (SNR), relative contrast (RC) and contrast to noise ratio (CNR) between muscle and bone marrow was performed, followed by a qualitative assessment of anatomic/pathologic structures and the extent of artefacts. At 3.0 T, 30 lesions (91%) compared to 33 lesions at 1.5 T were detected. The SNR/CNR/RC were moderately reduced at 3.0 T versus 1.5 T (muscle 42 vs 47 and bone 83 vs 112/46 vs 69/0.33 vs 0.43). Motion artefacts from the pulsating popliteal artery were significantly increased at 3.0 T. A visible and measurable signal loss occurred at 3.0 T using the built-in body coil compared with the dedicated 1.5 T knee coil, but nearly all clinically important information could be obtained.
Kaufman, Kenton R; Frittoli, Serena; Frigo, Carlo A
2012-06-01
Amputees walk with an asymmetrical gait, which may lead to future musculoskeletal degenerative changes. The purpose of this study was to compare the gait asymmetry of active transfemoral amputees while using a passive mechanical knee joint or a microprocessor-controlled knee joint. Objective 3D gait measurements were obtained in 15 subjects (12 men and 3 women; age 42, range 26-57). Research participants were longtime users of a mechanical prosthesis (mean 20 years, range 3-36 years). Joint symmetry was calculated using a novel method that includes the entire waveform throughout the gait cycle. There was no significant difference in hip, knee and ankle kinematics symmetry when using the different knee prostheses. In contrast, the results demonstrated a significant improvement in lower extremity joint kinetics symmetry when using the microprocessor-controlled knee. Use of the microprocessor-controlled knee joint resulted in improved gait symmetry. These improvements may lead to a reduction in the degenerative musculoskeletal changes often experienced by amputees. Copyright © 2011 Elsevier Ltd. All rights reserved.
Gait, A D; Hodgson, R; Parkes, M J; Hutchinson, C E; O'Neill, T W; Maricar, N; Marjanovic, E J; Cootes, T F; Felson, D T
2016-08-01
Synovium is increasingly a target of osteoarthritis (OA) treatment, yet its optimal measurement is unclear. Using dynamic contrast enhanced (DCE) MRI in knee OA patients before and after intraarticular steroid injection, we compared the responsiveness of static synovial volume measures to measures of dynamic changes in synovial enhancement, changes that are strongly related to synovial vascularity. Ninety three patients underwent DCE-MRI before and 1-2 weeks after intra-articular injection of 80 mg methylprednisolone. Synovium was segmented and volume, relative enhancement rate (RER), maximum relative enhancement (REmax), late relative enhancement (RElate) and pharmacokinetic parameters (K(trans), ve) were calculated. KOOS (knee injury and osteoarthritis outcome score) pain score was recorded before and after injection. Standardized change scores were calculated for each parameter. Linear regression and Pearson's correlations were used to investigate the relationship between change in MRI parameters and change in pain. The change in standardized score for the measures of synovial enhancement, RElate and REmax were -0.58 (95% CI -0.79 to -0.37) and -0.62 (95% CI -0.83 to -0.41) respectively, whereas the score for synovial volume was -0.30 (-0.52 to -0.09). Further, change in knee pain correlated more strongly with changes in enhancement (for both REmax and RElate, r = -0.27 (95% CI -0.45 to -0.07)) than with changes in synovial volume -0.15 (-0.35 to 0.05). This study suggests DCE-MRI derived measures of synovial enhancement may be more sensitive to the response to treatment and more strongly associated with changes in pain than synovial volume and may be better outcomes for assessment of structural effects of treatment in OA. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Simultaneous prediction of muscle and contact forces in the knee during gait.
Lin, Yi-Chung; Walter, Jonathan P; Banks, Scott A; Pandy, Marcus G; Fregly, Benjamin J
2010-03-22
Musculoskeletal models are currently the primary means for estimating in vivo muscle and contact forces in the knee during gait. These models typically couple a dynamic skeletal model with individual muscle models but rarely include articular contact models due to their high computational cost. This study evaluates a novel method for predicting muscle and contact forces simultaneously in the knee during gait. The method utilizes a 12 degree-of-freedom knee model (femur, tibia, and patella) combining muscle, articular contact, and dynamic skeletal models. Eight static optimization problems were formulated using two cost functions (one based on muscle activations and one based on contact forces) and four constraints sets (each composed of different combinations of inverse dynamic loads). The estimated muscle and contact forces were evaluated using in vivo tibial contact force data collected from a patient with a force-measuring knee implant. When the eight optimization problems were solved with added constraints to match the in vivo contact force measurements, root-mean-square errors in predicted contact forces were less than 10 N. Furthermore, muscle and patellar contact forces predicted by the two cost functions became more similar as more inverse dynamic loads were used as constraints. When the contact force constraints were removed, estimated medial contact forces were similar and lateral contact forces lower in magnitude compared to measured contact forces, with estimated muscle forces being sensitive and estimated patellar contact forces relatively insensitive to the choice of cost function and constraint set. These results suggest that optimization problem formulation coupled with knee model complexity can significantly affect predicted muscle and contact forces in the knee during gait. Further research using a complete lower limb model is needed to assess the importance of this finding to the muscle and contact force estimation process. Copyright (c) 2009 Elsevier Ltd. All rights reserved.
Development and fabrication of patient-specific knee implant using additive manufacturing techniques
NASA Astrophysics Data System (ADS)
Zammit, Robert; Rochman, Arif
2017-10-01
Total knee replacement is the most effective treatment to relief pain and restore normal function in a diseased knee joint. The aim of this research was to develop a patient-specific knee implant which can be fabricated using additive manufacturing techniques and has reduced wear rates using a highly wear resistant materials. The proposed design was chosen based on implant requirements, such as reduction in wear rates as well as strong fixation. The patient-specific knee implant improves on conventional knee implants by modifying the articulating surfaces and bone-implant interfaces. Moreover, tribological tests of different polymeric wear couples were carried out to determine the optimal materials to use for the articulating surfaces. Finite element analysis was utilized to evaluate the stresses sustained by the proposed design. Finally, the patient-specific knee implant was successfully built using additive manufacturing techniques.
Rehabilitation device with variable resistance and intelligent control
Dong, Shufang; Lu, Ke-Qian; Sun, J.Q.; Rudolph, Katherine
2008-01-01
Resistance exercise has been widely reported to have positive rehabilitation effects for patients with neuromuscular and orthopaedic conditions. This paper presents an optimal design of magneto-rheological fluid dampers for variable resistance exercise device in the form of a knee brace. An intelligent supervisory control for regulating the resistive force or torque of the knee brace has also been studied. The device provides both isometric and isokinetic strength training for the knee. PMID:15694609
Computational knee ligament modeling using experimentally determined zero-load lengths.
Bloemker, Katherine H; Guess, Trent M; Maletsky, Lorin; Dodd, Kevin
2012-01-01
This study presents a subject-specific method of determining the zero-load lengths of the cruciate and collateral ligaments in computational knee modeling. Three cadaver knees were tested in a dynamic knee simulator. The cadaver knees also underwent manual envelope of motion testing to find their passive range of motion in order to determine the zero-load lengths for each ligament bundle. Computational multibody knee models were created for each knee and model kinematics were compared to experimental kinematics for a simulated walk cycle. One-dimensional non-linear spring damper elements were used to represent cruciate and collateral ligament bundles in the knee models. This study found that knee kinematics were highly sensitive to altering of the zero-load length. The results also suggest optimal methods for defining each of the ligament bundle zero-load lengths, regardless of the subject. These results verify the importance of the zero-load length when modeling the knee joint and verify that manual envelope of motion measurements can be used to determine the passive range of motion of the knee joint. It is also believed that the method described here for determining zero-load length can be used for in vitro or in vivo subject-specific computational models.
Early detection of osteoarthritis in rabbits using MRI with a double-contrast agent.
Onishi, Okihiro; Ikoma, Kazuya; Kido, Masamitsu; Kabuto, Yukichi; Ueshima, Keiichiro; Matsuda, Ken-Ichi; Tanaka, Masaki; Kubo, Toshikazu
2018-03-13
Articular cartilage degeneration has been evaluated by magnetic resonance imaging (MRI). However, this method has several problems, including its time-consuming nature and the requirement of a high magnetic field or specialized hardware. The purpose of this study was to sequentially assess early degenerative changes in rabbit knee articular cartilage using MRI with a new double-contrast agent. We induced osteoarthritis (OA) in the right knee of rabbits by anterior cruciate ligament transection and partial medial meniscectomy. Proton density-weighted images and T 2 -calculated images were obtained before and after contrast agent injection into the knee. The signal intensity ratio (SIR) values on the proton density-weighted images were calculated by dividing the signal intensity of the articular cartilage by that of joint fluid. Six rabbits were examined using MRI at 2 (designated 2-w OA) and 4 weeks (4-w OA) after the operation. Histological examination was performed 4 weeks after the operation. One rabbit was histologically examined 2 weeks after the operation. The control consisted of six rabbits that were not subjected to the operation. The SIR values, T 2 values and the thicknesses of the cartilage of the 2-w OA, 4-w OA and the control before and after contrast agent injection were analyzed. The Mankin score and OARSI (Osteoarthritis Research Society International) score were used for the histological evaluation. Significant differences in the SIR and T 2 values of the medial and lateral condyles of the femur were found between the control and the 4-w OA only after contrast agent injection. No significant differences were found in the SIR and T 2 values before contrast agent injection between the control, the 2-w OA and 4-w OA. The thickness of the articular cartilage revealed no significant differences. In the histological assessment, the Mankin score and OARSI score sequentially increased from the control to the 4-w OA. We evaluated the SIR and T 2 values of the knees in a rabbit OA model and a control model using a new double-contrast agent. MRI with this agent enabled OA detection earlier than using conventional MRI.
Alizai, Hamza; Roemer, Frank W; Hayashi, Daichi; Crema, Michel D; Felson, David T; Guermazi, Ali
2015-03-01
Arthroscopy-based semiquantitative scoring systems such as Outerbridge and Noyes' scores were the first to be developed for the purpose of grading cartilage defects. As magnetic resonance imaging (MRI) became available for evaluation of the osteoarthritic knee joint, these systems were adapted for use with MRI. Later on, grading methods such as the Whole Organ Magnetic Resonance Score, the Boston-Leeds Osteoarthritis Knee Score and the MRI Osteoarthritis Knee Score were designed specifically for performing whole-organ assessment of the knee joint structures, including cartilage. Cartilage grades on MRI obtained with these scoring systems represent optimal outcome measures for longitudinal studies, and are designed to enhance understanding of the knee osteoarthritis disease process. The purpose of this narrative review is to describe cartilage assessment in knee osteoarthritis using currently available MRI-based semiquantitative whole-organ scoring systems, and to provide an update on the risk factors for cartilage loss in knee osteoarthritis as assessed with these scoring systems.
Jenny, J Y; Boeri, C
2001-01-01
A navigation system should improve the quality of a total knee prosthesis implantation in comparison to the classical, surgeon-controlled operative technique. The authors have implanted 40 knee total prostheses with an optical infrared navigation system (Orthopilot AESCULAP, Tuttlingen--group A). The quality of implantation was studied on postoperative long leg AP and lateral X-rays, and compared to a control group of 40 computer-paired total knee prostheses o the same model (Search Prosthesis, AESCULAP, Tuttlingen) implanted with a classical, surgeon-controlled technique (group B). An optimal mechanical femorotibial angle (3 degrees valgus to 3 degrees varus) was obtained by 33 cases in group A and 31 cases in group B (p > 0.05). Better results were seen for the coronal and sagittal orientation of both tibial and femoral components in group A. Globally, 26 cases of the group A and 12 cases of the group B were implanted in an optimal manner for all studied criteria (p < 0.01). The used navigation system allows a significant improvement of the quality of implantation of a knee total prosthesis in comparison to a classical, surgeon-controlled instrumentation. Long-term outcome could be consequently improved.
Stance control knee mechanism for lower-limb support in hybrid neuroprosthesis
To, Curtis S.; Kobetic, Rudi; Bulea, Thomas C.; Audu, Musa L.; Schnellenberger, John R.; Pinault, Gilles; Triolo, Ronald J.
2014-01-01
A hydraulic stance control knee mechanism (SCKM) was developed to fully support the knee against flexion during stance and allow uninhibited motion during swing for individuals with paraplegia using functional neuromuscular stimulation (FNS) for gait assistance. The SCKM was optimized for maximum locking torque for body-weight support and minimum resistance when allowing for free knee motion. Ipsilateral and contralateral position and force feedback were used to control the SCKM. Through bench and nondisabled testing, the SCKM was shown to be capable of supporting up to 70 N-m, require no more than 13% of the torque achievable with FNS to facilitate free motion, and responsively and repeatedly unlock under an applied flexion knee torque of up to 49 N-m. Preliminary tests of the SCKM with an individual with paraplegia demonstrated that it could support the body and maintain knee extension during stance without the stimulation of the knee extensor muscles. This was achieved without adversely affecting gait, and knee stability was comparable to gait assisted by knee extensor stimulation during stance. PMID:21938668
Three-dimensional knee motion before and after high tibial osteotomy for medial knee osteoarthritis.
Takemae, Takashi; Omori, Go; Nishino, Katsutoshi; Terajima, Kazuhiro; Koga, Yoshio; Endo, Naoto
2006-11-01
High tibial osteotomy (HTO) is an established surgical option for treating medial knee osteoarthritis. HTO moves the mechanical load on the knee joint from the medial compartment to the lateral compartment by changing the leg alignment, but the effects of the operation remain unclear. The purpose of this study was to evaluate the change in three-dimensional knee motion before and after HTO, focusing on lateral thrust and screw home movement, and to investigate the relationship between the change in knee motion and the clinical results. A series of 19 patients with medial knee osteoarthritis who had undergone HTO were evaluated. We performed a clinical assessment, radiological evaluation, and motion analysis at 2.4 years postoperatively. The clinical assessment was performed using the Japanese Orthopaedic Association knee score. The score was significantly improved in all patients after operation. Motion analysis revealed that lateral thrust, which was observed in 18 of the 20 knees before operation, was reduced to 7 knees after operation. Regarding active terminal extension of the knee, three patterns of rotational movement were observed before operation: screw home movement (external rotation), reverse screw home movement (internal rotation), and no rotation. By contrast, after operation, only reverse screw home movement and no rotation were observed; the screw home movement disappeared in all patients. In the knees with reverse screw home movement after operation, the preoperative score was significantly lower than those in the knees with no rotation after operation. Kinetically, HTO was useful for suppressing lateral thrust in medial knee osteoarthritis, although the rotational movement of the knee joint was unchanged.
Shape optimization of tibial prosthesis components
NASA Technical Reports Server (NTRS)
Saravanos, D. A.; Mraz, P. J.; Davy, D. T.
1993-01-01
NASA technology and optimal design methodologies originally developed for the optimization of composite structures (engine blades) are adapted and applied to the optimization of orthopaedic knee implants. A method is developed enabling the shape tailoring of the tibial components of a total knee replacement implant for optimal interaction within the environment of the tibia. The shape of the implant components are optimized such that the stresses in the bone are favorably controlled to minimize bone degradation, to improve the mechanical integrity of the implant/interface/bone system, and to prevent failures of the implant components. A pilot tailoring system is developed and the feasibility of the concept is demonstrated and evaluated. The methodology and evolution of the existing aerospace technology from which this pilot optimization code was developed is also presented and discussed. Both symmetric and unsymmetric in-plane loading conditions are investigated. The results of the optimization process indicate a trend toward wider and tapered posts as well as thicker backing trays. Unique component geometries were obtained for the different load cases.
Sodium inversion recovery MRI on the knee joint at 7 T with an optimal control pulse.
Lee, Jae-Seung; Xia, Ding; Madelin, Guillaume; Regatte, Ravinder R
2016-01-01
In the field of sodium magnetic resonance imaging (MRI), inversion recovery (IR) is a convenient and popular method to select sodium in different environments. For the knee joint, IR has been used to suppress the signal from synovial fluids, which improves the correlation between the sodium signal and the concentration of glycosaminoglycans (GAGs) in cartilage tissues. For the better inversion of the magnetization vector under the spatial variations of the B0 and B1 fields, the IR sequence usually employ adiabatic pulses as the inversion pulse. On the other hand, it has been shown that RF shapes robust against the variations of the B0 and B1 fields can be generated by numerical optimization based on optimal control theory. In this work, we compare the performance of fluid-suppressed sodium MRI on the knee joint in vivo, between one implemented with an adiabatic pulse in the IR sequence and the other with the adiabatic pulse replaced by an optimal-control shaped pulse. While the optimal-control pulse reduces the RF power deposited to the body by 58%, the quality of fluid suppression and the signal level of sodium within cartilage are similar between two implementations. Copyright © 2015 Elsevier Inc. All rights reserved.
Kinematic analysis of total knee prosthesis designed for Asian population.
Low, F H; Khoo, L P; Chua, C K; Lo, N N
2000-01-01
In designing a total knee replacement (TKR) prosthesis catering for the Asian population, 62 sets of femur were harvested and analyzed. The morphometrical data obtained were found to be in good agreement with dimensions typical of the Asian knee and has reaffirmed the fact that Caucasian knees are generally larger than Asian knees. Subsequently, these data when treated using a multivariate statistical technique resulted in the establishment of major design parameters for six different sizes of femoral implants. An extra-small implant size with established dimensions and geometrical shape has surfaced from the study. The differences between the Asian knees and the Caucasian knees are discussed. Employing the established femoral dimensions and motion path of the knee joint, the articulating tibia profile was generated. All the sizes of implants were modeled using a computer-aided software package. Thereupon, these models that accurately fits the local Asian knee were transported into a dynamic and kinematic analysis software package. The tibiofemoral joint was modeled successfully as a slide curve joint to study intuitively the motion of the femur when articulating on the tibia surface. An optimal tibia profile could be synthesized to mimic the natural knee path motion. Details of the analysis are presented and discussed.
Yang, Zhaochun; Wickwire, Alexis C; Debski, Richard E
2010-11-01
Recent clinical evidence has suggested that tasks performed in kneeling or squatting postures place the knee at a higher risk for injury because loads across the knee might overload the ligaments. The objective of this study was to develop a subject-specific model of the knee that is kinematically driven to predict the forces in the major ligaments at high flexion angles. The geometry of the femur, tibia, and fibula and the load-elongation curves representing the structural properties of the ACL, PCL, LCL, and MCL served as inputs to the model, which represented each ligament as a nonlinear elastic spring. To drive the model, kinematic data was obtained while loads were applied to the same cadaveric knee at four flexion angles. The force in each ligament during the recorded kinematic data allowed an optimization procedure to determine the location of the ligament attachment sites on each bone and their reference lengths. The optimization procedure could successfully minimize the differences between the experimental and predicted forces only when the kinematics at 90°, 120°, and 140° of flexion were utilized. This finding suggests that the ligaments at the knee function differently at high-flexion angles compared to low flexion angles and separate models must be used to examine each range of motion. In the future, the novel experimental and computational methodology will be used to construct additional models and additional knee kinematics will be input to help elucidate mechanisms of injury during tasks performed in kneeling or squatting postures.
NASA Astrophysics Data System (ADS)
Nagarajan, Mahesh B.; Coan, Paola; Huber, Markus B.; Yang, Chien-Chun; Glaser, Christian; Reiser, Maximilian F.; Wismüller, Axel
2012-03-01
The current approach to evaluating cartilage degeneration at the knee joint requires visualization of the joint space on radiographic images where indirect cues such as joint space narrowing serve as markers for osteoarthritis. A recent novel approach to visualizing the knee cartilage matrix using phase contrast CT imaging (PCI-CT) was shown to allow direct examination of chondrocyte cell patterns and their subsequent correlation to osteoarthritis. This study aims to characterize chondrocyte cell patterns in the radial zone of the knee cartilage matrix in the presence and absence of osteoarthritic damage through both gray-level co-occurrence matrix (GLCM) derived texture features as well as Minkowski Functionals (MF). Thirteen GLCM and three MF texture features were extracted from 404 regions of interest (ROI) annotated on PCI images of healthy and osteoarthritic specimens of knee cartilage. These texture features were then used in a machine learning task to classify ROIs as healthy or osteoarthritic. A fuzzy k-nearest neighbor classifier was used and its performance was evaluated using the area under the ROC curve (AUC). The best classification performance was observed with the MF features 'perimeter' and 'Euler characteristic' and with GLCM correlation features (f3 and f13). With the experimental conditions used in this study, both Minkowski Functionals and GLCM achieved a high classification performance (AUC value of 0.97) in the task of distinguishing between health and osteoarthritic ROIs. These results show that such quantitative analysis of chondrocyte patterns in the knee cartilage matrix can distinguish between healthy and osteoarthritic tissue with high accuracy.
Cementless total knee arthroplasty
Risitano, Salvatore; Sabatini, Luigi; Giachino, Matteo; Agati, Gabriele; Massè, Alessandro
2016-01-01
Interest for uncemented total knee arthroplasty (TKA) has greatly increased in recent years. This technique, less used than cemented knee replacement in the last decades, sees a revival thanks an advance in prosthetic design, instrumentation and operative technique. The related literature in some cases shows conflicting data on survival and on the revision’s rate, but in most cases a success rate comparable to cemented TKA is reported. The optimal fixation in TKA is a subject of debate with the majority of surgeons favouring cemented fixation. PMID:27162779
Computational Knee Ligament Modeling Using Experimentally Determined Zero-Load Lengths
Bloemker, Katherine H; Guess, Trent M; Maletsky, Lorin; Dodd, Kevin
2012-01-01
This study presents a subject-specific method of determining the zero-load lengths of the cruciate and collateral ligaments in computational knee modeling. Three cadaver knees were tested in a dynamic knee simulator. The cadaver knees also underwent manual envelope of motion testing to find their passive range of motion in order to determine the zero-load lengths for each ligament bundle. Computational multibody knee models were created for each knee and model kinematics were compared to experimental kinematics for a simulated walk cycle. One-dimensional non-linear spring damper elements were used to represent cruciate and collateral ligament bundles in the knee models. This study found that knee kinematics were highly sensitive to altering of the zero-load length. The results also suggest optimal methods for defining each of the ligament bundle zero-load lengths, regardless of the subject. These results verify the importance of the zero-load length when modeling the knee joint and verify that manual envelope of motion measurements can be used to determine the passive range of motion of the knee joint. It is also believed that the method described here for determining zero-load length can be used for in vitro or in vivo subject-specific computational models. PMID:22523522
Multimodal imaging of the human knee down to the cellular level
NASA Astrophysics Data System (ADS)
Schulz, G.; Götz, C.; Müller-Gerbl, M.; Zanette, I.; Zdora, M.-C.; Khimchenko, A.; Deyhle, H.; Thalmann, P.; Müller, B.
2017-06-01
Computed tomography reaches the best spatial resolution for the three-dimensional visualization of human tissues among the available nondestructive clinical imaging techniques. Nowadays, sub-millimeter voxel sizes are regularly obtained. Regarding investigations on true micrometer level, lab-based micro-CT (μCT) has become gold standard. The aim of the present study is firstly the hierarchical investigation of a human knee post mortem using hard X-ray μCT and secondly a multimodal imaging using absorption and phase contrast modes in order to investigate hard (bone) and soft (cartilage) tissues on the cellular level. After the visualization of the entire knee using a clinical CT, a hierarchical imaging study was performed using the lab-system nanotom® m. First, the entire knee was measured with a pixel length of 65 μm. The highest resolution with a pixel length of 3 μm could be achieved after extracting cylindrically shaped plugs from the femoral bones. For the visualization of the cartilage, grating-based phase contrast μCT (I13-2, Diamond Light Source) was performed. With an effective voxel size of 2.3 μm it was possible to visualize individual chondrocytes within the cartilage.
Modelling of the Human Knee Joint Supported by Active Orthosis
NASA Astrophysics Data System (ADS)
Musalimov, V.; Monahov, Y.; Tamre, M.; Rõbak, D.; Sivitski, A.; Aryassov, G.; Penkov, I.
2018-02-01
The article discusses motion of a healthy knee joint in the sagittal plane and motion of an injured knee joint supported by an active orthosis. A kinematic scheme of a mechanism for the simulation of a knee joint motion is developed and motion of healthy and injured knee joints are modelled in Matlab. Angles between links, which simulate the femur and tibia are controlled by Simulink block of Model predictive control (MPC). The results of simulation have been compared with several samples of real motion of the human knee joint obtained from motion capture systems. On the basis of these analyses and also of the analysis of the forces in human lower limbs created at motion, an active smart orthosis is developed. The orthosis design was optimized to achieve an energy saving system with sufficient anatomy, necessary reliability, easy exploitation and low cost. With the orthosis it is possible to unload the knee joint, and also partially or fully compensate muscle forces required for the bending of the lower limb.
Effect of hip and knee position on nerve conduction in the common fibular nerve.
Broadhurst, Peter Kaas; Robinson, Lawrence R
2017-09-01
The aim of this study was to measure the influence that hip and knee position have on routine fibular motor nerve conduction studies. Healthy subjects under age 40 were recruited (n = 24) to have fibular nerve conduction studies completed in various positions, using hip extension-knee extension as a control. A mean increase in conduction velocity of 2.5 m/s across the knee (P = 0.020) was seen during hip flexion compared with hip extension. A mean decrease in velocity of 1.6 m/s through the leg segment (P = 0.016) was seen during knee flexion compared with knee extension. This study shows that the optimal position of the leg during fibular nerve studies is with the hip in flexion and knee in extension, to more accurately reflect nerve length for velocity calculations. This may have implications for other peripheral nerves with respect to proximal joint position affecting calculated velocity. Muscle Nerve 56: 519-521, 2017. © 2017 Wiley Periodicals, Inc.
Optimality Principles for Model-Based Prediction of Human Gait
Ackermann, Marko; van den Bogert, Antonie J.
2010-01-01
Although humans have a large repertoire of potential movements, gait patterns tend to be stereotypical and appear to be selected according to optimality principles such as minimal energy. When applied to dynamic musculoskeletal models such optimality principles might be used to predict how a patient’s gait adapts to mechanical interventions such as prosthetic devices or surgery. In this paper we study the effects of different performance criteria on predicted gait patterns using a 2D musculoskeletal model. The associated optimal control problem for a family of different cost functions was solved utilizing the direct collocation method. It was found that fatigue-like cost functions produced realistic gait, with stance phase knee flexion, as opposed to energy-related cost functions which avoided knee flexion during the stance phase. We conclude that fatigue minimization may be one of the primary optimality principles governing human gait. PMID:20074736
Using Aerospace Technology To Design Orthopedic Implants
NASA Technical Reports Server (NTRS)
Saravanos, D. A.; Mraz, P. J.; Davy, D. T.
1996-01-01
Technology originally developed to optimize designs of composite-material aerospace structural components used to develop method for optimizing designs of orthopedic implants. Development effort focused on designing knee implants, long-term goal to develop method for optimizing designs of orthopedic implants in general.
Zheng, Keke; Scholes, Corey J; Chen, Junning; Parker, David; Li, Qing
2017-04-01
Medial opening wedge high tibial osteotomy (MOWHTO) is a surgical procedure to treat knee osteoarthritis associated with varus deformity. However, the ideal final alignment of the Hip-Knee-Ankle (HKA) angle in the frontal plane, that maximizes procedural success and post-operative knee function, remains controversial. Therefore, the purpose of this study was to introduce a subject-specific modeling procedure in determining the biomechanical effects of MOWHTO alignment on tibiofemoral cartilage stress distribution. A 3D finite element knee model derived from magnetic resonance imaging of a healthy participant was manipulated in-silico to simulate a range of final HKA angles (i.e. 0.2°, 2.7°, 3.9° and 6.6° valgus). Loading and boundary conditions were assigned based on subject-specific kinematic and kinetic data from gait analysis. Multiobjective optimization was used to identify the final alignment that balanced compressive and shear forces between medial and lateral knee compartments. Peak stresses decreased in the medial and increased in the lateral compartment as the HKA was shifted into valgus, with balanced loading occurring at angles of 4.3° and 2.9° valgus for the femoral and tibial cartilage respectively. The concept introduced here provides a platform for non-invasive, patient-specific preoperative planning of the osteotomy for medial compartment knee osteoarthritis. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Dessery, Yoann; Belzile, Étienne; Turmel, Sylvie; Corbeil, Philippe
2017-08-01
There is contradictory evidence regarding whether the addition of medial arch supports to laterally wedged insoles reduces knee adduction moment, improves comfort, and reduces knee pain during the late stance phase of gait. To verify if such effects occur in participants with medial knee osteoarthritis. Randomized single-blinded study. Gait analysis was performed on 18 patients affected by medial knee osteoarthritis. Pain and comfort scores, frontal plane kinematics and kinetics of ankle, knee, and hip were compared in four conditions: without foot orthosis, with foot orthoses, with medial arch support, and with foot orthoses with medial arch support and lateral wedge insoles with 6° and 10° inclination. Lower-extremity gait kinetics were characterized by a significant decrease, greater than 6%, in second peak knee adduction moment in laterally wedged insole conditions compared to the other conditions ( p < 0.001; effect size = 0.6). No significant difference in knee adduction moment was observed between laterally wedged insole conditions. In contrast, a significant increase of 7% in knee adduction moment during the loading response was observed in the customized foot orthoses without lateral inclination condition ( p < 0.001; effect size = 0.3). No difference was found in comfort or pain ratings between conditions. Our study suggests that customized foot orthoses with a medial arch support may only be suitable for the management of medial knee osteoarthritis when a lateral wedge is included. Clinical relevance Our data suggest that customized foot orthoses with medial arch support and a lateral wedge reduce knee loading in patients with medial knee osteoarthritis (KOA). We also found evidence that medial arch support may increase knee loading, which could potentially be detrimental in KOA patients.
Dai, B; Butler, R J; Garrett, W E; Queen, R M
2014-12-01
Asymmetries in sagittal plane knee kinetics have been identified as a risk factor for anterior cruciate ligament (ACL) re-injury. Clinical tools are needed to identify the asymmetries. This study examined the relationships between knee kinetic asymmetries and ground reaction force (GRF) asymmetries during athletic tasks in adolescent patients following ACL reconstruction (ACL-R). Kinematic and GRF data were collected during a stop-jump task and a side-cutting task for 23 patients. Asymmetry indices between the surgical and non-surgical limbs were calculated for GRF and knee kinetic variables. For the stop-jump task, knee kinetics asymmetry indices were correlated with all GRF asymmetry indices (P < 0.05), except for loading rate. Vertical GRF impulse asymmetry index predicted peak knee moment, average knee moment, and knee work (R(2) ≥ 0.78, P < 0.01) asymmetry indices. For the side-cutting tasks, knee kinetic asymmetry indices were correlated with the peak propulsion vertical GRF and vertical GRF impulse asymmetry indices (P < 0.05). Vertical GRF impulse asymmetry index predicted peak knee moment, average knee moment, and knee work (R(2) ≥ 0.55, P < 0.01) asymmetry indices. The vertical GRF asymmetries may be a viable surrogate for knee kinetic asymmetries and therefore may assist in optimizing rehabilitation outcomes and minimizing re-injury rates. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Henriksen, Marius; Aaboe, Jens; Bliddal, Henning
2012-08-01
In a cross sectional study, we investigated the relationships between knee pain and mechanical loading across the knee, as indicated by the external knee adduction moment (KAM) during walking in patients with symptomatic knee OA who were distinguished by different radiographic disease severities. Data from 137 symptomatic medial knee OA patients were used. Based on Kellgren/Lawrence (K/L) grading, the patients were divided into radiographically less severe (K/L ≤ 2, n=68) or severe (K/L>2, n=69) medial knee OA. Overall knee pain was rated on a 10 cm visual analog scale, and peak KAM and KAM impulses were obtained from gait analyses. Mixed linear regression analyses were performed with KAM variables as the outcome, and pain and disease severity as independent variables, adjusting for age, gender, and walking speed. In adjusted analyses, less severe patients demonstrated negative relationships between pain intensities and dynamic loading. The severe patient group showed no relationship between pain intensity and peak KAM, and a positive relationship between pain intensity and KAM impulse. In radiographically less severe knee OA, the negative relationships between pain intensity and dynamic knee joint loading indicate a natural reaction to pain, which will limit the stress on the joint. In contrast, either absent or positive relationships between pain and dynamic loading in severe OA may lead to overuse and accelerated disease progression. These findings may have a large potential interest for strategies of treatment in knee OA. Copyright © 2011 Elsevier B.V. All rights reserved.
Taylor, Alden L; Wilken, Jason M; Deyle, Gail D; Gill, Norman W
2014-04-01
Descriptive biomechanical study using an experimental repeated-measures design. To quantify the response of participants with and without knee osteoarthritis (OA) to a single session of manual physical therapy. The intervention consisted primarily of joint mobilization techniques, supplemented by exercises, aiming to improve knee extension. While manual therapy benefits patients with knee OA, there is limited research quantifying the effects of a manual therapy treatment session on either motion or stiffness of osteoarthritic and normal knees. Methods The study included 5 participants with knee OA and 5 age-, gender-, and body mass index-matched healthy volunteers. Knee extension motion and stiffness were measured with videofluoroscopy before and after a 30-minute manual therapy treatment session. Analysis of variance and intraclass correlation coefficients were used to analyze the data. Participants with knee OA had restricted knee extension range of motion at baseline, in contrast to the participants with normal knees, who had full knee extension. After the therapy session, there was a significant increase in knee motion in participants with knee OA (P = .004) but not in those with normal knees (P = .201). For stiffness data, there was no main effect for time (P = .903) or load (P = .274), but there was a main effect of group (P = .012), with the participants with healthy knees having greater stiffness than those with knee OA. Reliability, using intraclass correlation coefficient model 3,3, for knee angle measurements between imaging sessions for all loading conditions was 0.99. Reliability (intraclass correlation coefficient model 3,1) for intraimage measurements was 0.97. End-range knee extension stiffness was greater in the participants with normal knees than those with knee OA. The combination of lesser stiffness and lack of motion in those with knee OA, which may indicate the potential for improvement, may explain why increased knee extension angle was observed following a single session of manual therapy in the participants with knee OA but not in those with normal knees. Videofluoroscopy of the knee appears reliable and relevant for future studies attempting to quantify the underlying mechanisms of manual therapy. J Orthop Sports Phys Ther 2014;44(4):273-282. Epub 25 February 2014. doi:10.2519/jospt.2014.4710.
Improvement of the knee center of rotation during walking after opening wedge high tibial osteotomy.
Kim, Kyungsoo; Feng, Jun; Nha, Kyung Wook; Park, Won Man; Kim, Yoon Hyuk
2015-06-01
Accurate measurement of the center of rotation of the knee joint is indispensable for prediction of joint kinematics and kinetics in musculoskeletal models. However, no study has yet identified the knee center of rotations during several daily activities before and after high tibial osteotomy surgery, which is one surgical option for treating knee osteoarthritis. In this study, an estimation method for determining the knee joint center of rotation was developed by applying the optimal common shape technique and symmetrical axis of rotation approach techniques to motion-capture data and validated for typical activities (walking, squatting, climbing up stairs, walking down stairs) of 10 normal subjects. The locations of knee joint center of rotations for injured and contralateral knees of eight subjects with osteoarthritis, both before and after high tibial osteotomy surgery, were then calculated during walking. It was shown that high tibial osteotomy surgery improved the knee joint center of rotation since the center of rotations for the injured knee after high tibial osteotomy surgery were significantly closer to those of the normal healthy population. The difference between the injured and contralateral knees was also generally reduced after surgery, demonstrating increased symmetry. These results indicate that symmetry in both knees can be recovered in many cases after high tibial osteotomy surgery. Moreover, the recovery of center of rotation in the injured knee was prior to that of symmetry. This study has the potential to provide fundamental information that can be applied to understand abnormal kinematics in patients, diagnose knee joint disease, and design a novel implants for knee joint surgeries. © IMechE 2015.
Sayre, Eric C; Xie, Hui; Falck, Ryan S; Best, John R; Liu-Ambrose, Teresa; Grewal, Navi; Hoens, Alison M; Noonan, Greg; Feehan, Lynne M
2018-01-01
Background Current practice guidelines emphasize the use of physical activity as the first-line treatment of knee osteoarthritis; however, up to 90% of people with osteoarthritis are inactive. Objective We aimed to assess the efficacy of a technology-enabled counseling intervention for improving physical activity in people with either a physician-confirmed diagnosis of knee osteoarthritis or having passed two validated criteria for early osteoarthritis. Methods We conducted a proof-of-concept randomized controlled trial. The immediate group received a brief education session by a physical therapist, a Fitbit Flex, and four biweekly phone calls for activity counseling. The delayed group received the same intervention 2 months later. Participants were assessed at baseline (T0) and at the end of 2 months (T1), 4 months (T2), and 6 months (T3). Outcomes included (1) mean time on moderate-to-vigorous physical activity (MVPA ≥3 metabolic equivalents [METs], primary outcome), (2) mean time on MVPA ≥4 METs, (3) mean daily steps, (4) mean time on sedentary activities, (5) Knee Injury and Osteoarthritis Outcome Score (KOOS), and (6) Partners in Health scale. Mixed-effects repeated measures analysis of variance was used to assess five planned contrasts of changes in outcome measures over measurement periods. The five contrasts were (1) immediate T1-T0 vs delayed T1-T0, (2) delayed T2-T1 vs delayed T1-T0, (3) mean of contrast 1 and contrast 2, (4) immediate T1-T0 vs delayed T2-T1, and (5) mean of immediate T2-T1 and delayed T3-T2. The first three contrasts estimate the between-group effects. The latter two contrasts estimate the effect of the 2-month intervention delay on outcomes. Results We recruited 61 participants (immediate: n=30; delayed: n=31). Both groups were similar in age (immediate: mean 61.3, SD 9.4 years; delayed: mean 62.1, SD 8.5 years) and body mass index (immediate: mean 29.2, SD 5.5 kg/m2; delayed: mean 29.2, SD 4.8 kg/m2). Contrast analyses revealed significant between-group effects in MVPA ≥3 METs (contrast 1 coefficient: 26.6, 95% CI 4.0-49.1, P=.02; contrast 3 coefficient: 26.0, 95% CI 3.1-49.0, P=.03), daily steps (contrast 1 coefficient: 1699.2, 95% CI 349.0-3049.4, P=.02; contrast 2 coefficient: 1601.8, 95% CI 38.7-3164.9, P=.045; contrast 3 coefficient: 1650.5, 95% CI 332.3-2968.7; P=.02), KOOS activity of daily living subscale (contrast 1 coefficient: 6.9, 95% CI 0.1-13.7, P=.047; contrast 3 coefficient: 7.2, 95% CI 0.8-13.6, P=.03), and KOOS quality of life subscale (contrast 1 coefficient: 7.4, 95% CI 0.0-14.7, P=.049; contrast 3 coefficient: 7.3, 95% CI 0.1-14.6, P=.048). We found no significant effect in any outcome measures due to the 2-month delay of the intervention. Conclusions Our counseling program improved MVPA ≥3 METs, daily steps, activity of daily living, and quality of life in people with knee osteoarthritis. These findings are important because an active lifestyle is an important component of successful self-management. Trial Registration ClinicalTrials.gov NCT02315664; https://clinicaltrials.gov/ct2/show/NCT02315664 (Archived by WebCite at http://www.webcitation.org/6ynSgUyUC) PMID:29712630
Local contrast-enhanced MR images via high dynamic range processing.
Chandra, Shekhar S; Engstrom, Craig; Fripp, Jurgen; Neubert, Ales; Jin, Jin; Walker, Duncan; Salvado, Olivier; Ho, Charles; Crozier, Stuart
2018-09-01
To develop a local contrast-enhancing and feature-preserving high dynamic range (HDR) image processing algorithm for multichannel and multisequence MR images of multiple body regions and tissues, and to evaluate its performance for structure visualization, bias field (correction) mitigation, and automated tissue segmentation. A multiscale-shape and detail-enhancement HDR-MRI algorithm is applied to data sets of multichannel and multisequence MR images of the brain, knee, breast, and hip. In multisequence 3T hip images, agreement between automatic cartilage segmentations and corresponding synthesized HDR-MRI series were computed for mean voxel overlap established from manual segmentations for a series of cases. Qualitative comparisons between the developed HDR-MRI and standard synthesis methods were performed on multichannel 7T brain and knee data, and multisequence 3T breast and knee data. The synthesized HDR-MRI series provided excellent enhancement of fine-scale structure from multiple scales and contrasts, while substantially reducing bias field effects in 7T brain gradient echo, T 1 and T 2 breast images and 7T knee multichannel images. Evaluation of the HDR-MRI approach on 3T hip multisequence images showed superior outcomes for automatic cartilage segmentations with respect to manual segmentation, particularly around regions with hyperintense synovial fluid, across a set of 3D sequences. The successful combination of multichannel/sequence MR images into a single-fused HDR-MR image format provided consolidated visualization of tissues within 1 omnibus image, enhanced definition of thin, complex anatomical structures in the presence of variable or hyperintense signals, and improved tissue (cartilage) segmentation outcomes. © 2018 International Society for Magnetic Resonance in Medicine.
Effect of training on corticomotor excitability in clinical neck pain.
Rittig-Rasmussen, B; Kasch, H; Fuglsang-Frederiksen, A; Svensson, P; Jensen, T S
2014-09-01
Corticomotor excitability has been shown to correlate with motor learning and functional recovery. The aim of the present study was to monitor changes in excitability of the corticomotor pathways induced by neck training and to compare the effects in patients with neck or knee pain and pain-free participants. Corticomotor excitability was assessed using transcranial magnetic stimulation and electromyography at baseline, after 30 min and 1 h, and at a 1-week follow-up visit. The primary outcome measures were changes in amplitudes and latencies of motor evoked potentials (MEPs) at 1-week follow-up. MEP responses induced by neck training yielded significantly different outcomes in the three groups. In the group with neck pain and training, MEP amplitudes were significantly reduced between baseline and 30 min (p ≤ 0.05), but with no significant difference between baseline, 1 h (p = 0.178) and 1 week (p = 0.067). In the group with knee pain and training, MEP amplitudes significantly increased between baseline and 30 min (p ≤ 0.01) and 1 h (p < 0.001), but not after 1 week (p = 0.524) compared with baseline. In the pain-free group, there were no changes over time. Neck training reduced neuroplastic responsiveness of corticomotor pathways in neck pain patients in contrast to knee pain patients and pain-free participants. Increased attention to adaptive and maladaptive neuroplastic responses induced by training may prove valuable in the process of optimizing clinical outcomes. © 2014 European Pain Federation - EFIC®
Hard X-ray index of refraction tomography of a whole rabbit knee joint: A feasibility study.
Gasilov, S; Mittone, A; Horng, A; Geith, T; Bravin, A; Baumbach, T; Coan, P
2016-12-01
We report results of the computed tomography reconstruction of the index of refraction in a whole rabbit knee joint examined at the photon energy of 51keV. Refraction based images make it possible to delineate the bone, cartilage, and soft tissues without adjusting the contrast window width and level. Density variations, which are related to tissue composition and are not visible in absorption X-ray images, are detected in the obtained refraction based images. We discuss why refraction-based images provide better detectability of low contrast features than absorption images. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Robinson, K. Sue; Anderson, David R.; Gross, Michael; Petrie, David; Leighton, Ross; Stanish, William; Alexander, David; Mitchell, Michael; Mason, William; Flemming, Bruce; Fairhurst-Vaughan, Marlene; Gent, Michael
1998-01-01
Objective To determine whether compression ultrasonography or clinical examination should be considered as screening tests for the diagnosis of deep vein thrombosis (DVT) after total hip or knee arthroplasty in patients receiving warfarin prophylaxis postoperatively. Design A prospective cohort study. Setting A single tertiary care orthopedic centre. Patients One hundred and eleven patients who underwent elective total hip or knee arthroplasty were enrolled. Postoperatively the warfarin dose was adjusted daily to maintain the international normalized ratio between 1.8 and 2.5. Eighty-six patients successfully completed the study protocol. Intervention Before they were discharged from hospital, patients were assessed for DVT by clinical examination, bilateral compression ultrasonography of the proximal venous system and bilateral contrast venography. Results DVT was found in 29 patients (34%; 95% confidence interval [CI] 24% to 45%), and 6 patients (7%; 95% CI 3% to 15%) had proximal DVT. DVT developed in 18 (40%) of 45 patients who underwent total knee arthroplasty and in 11 (27%) of 41 patients who underwent total hip arthroplasty. The sensitivity of compression ultrasonography for the diagnosis of proximal DVT was 83% (95% CI 36% to 99%) and the specificity was 98% (95% CI 91% to 99%). The positive predictive value of compression ultrasonography was 71%. In contrast, clinical examination for DVT had a sensitivity of 11% (95% CI 2% to 28%) and a positive predictive value of 25%. Conclusions DVT is a common complication after total hip or knee arthroplasty. Compression ultrasonography appears to be a relatively accurate noninvasive test for diagnosing postoperative proximal DVT. In contrast, clinical examination is a very insensitive test. Whether routine use of screening compression ultrasonography will reduce the morbidity of venous thromboembolism after joint arthroplasty requires confirmation in a prospective trial involving long-term follow-up of patients. PMID:9793503
Jung, Yihwan; Phan, Cong-Bo; Koo, Seungbum
2016-02-01
Joint contact forces measured with instrumented knee implants have not only revealed general patterns of joint loading but also showed individual variations that could be due to differences in anatomy and joint kinematics. Musculoskeletal human models for dynamic simulation have been utilized to understand body kinetics including joint moments, muscle tension, and knee contact forces. The objectives of this study were to develop a knee contact model which can predict knee contact forces using an inverse dynamics-based optimization solver and to investigate the effect of joint constraints on knee contact force prediction. A knee contact model was developed to include 32 reaction force elements on the surface of a tibial insert of a total knee replacement (TKR), which was embedded in a full-body musculoskeletal model. Various external measurements including motion data and external force data during walking trials of a subject with an instrumented knee implant were provided from the Sixth Grand Challenge Competition to Predict in vivo Knee Loads. Knee contact forces in the medial and lateral portions of the instrumented knee implant were also provided for the same walking trials. A knee contact model with a hinge joint and normal alignment could predict knee contact forces with root mean square errors (RMSEs) of 165 N and 288 N for the medial and lateral portions of the knee, respectively, and coefficients of determination (R2) of 0.70 and -0.63. When the degrees-of-freedom (DOF) of the knee and locations of leg markers were adjusted to account for the valgus lower-limb alignment of the subject, RMSE values improved to 144 N and 179 N, and R2 values improved to 0.77 and 0.37, respectively. The proposed knee contact model with subject-specific joint model could predict in vivo knee contact forces with reasonable accuracy. This model may contribute to the development and improvement of knee arthroplasty.
Bryant, Adam L; Creaby, Mark W; Newton, Robert U; Steele, Julie R
2008-12-01
The purpose of this study was to investigate the relation between knee functionality of anterior cruciate ligament deficient (ACLD) and anterior cruciate ligament reconstruction (ACLR) patients and hamstring antagonist torque generated during resisted knee extension. Cross-sectional. Laboratory based. Male ACLD subjects (n=10) (18-35 y) and 27 matched males who had undergone ACLR (14 patella tendon [PT] grafts and 13 combined semitendinosus/gracilis tendon grafts). Not applicable. Knee functionality was rated (0- to 100-point scale) by using the Cincinnati Knee Rating System. Using electromyography data from the semitendinosus (ST) and biceps femoris muscles, we created a mathematical model to estimate the opposing torque generated by the hamstrings during isokinetic knee extension in 10 degrees intervals from 80 degrees to 10 degrees knee flexion. Pearson product-moment correlations revealed that more functional ACLD subjects generated significantly (P<.05) higher hamstring antagonist torque throughout knee extension. In contrast, more functional PT subjects produced significantly lower hamstring antagonist torque at 80 degrees to 70 degrees knee flexion, whereas no significant associations were found between hamstring antagonist torque and knee functionality for the ST/gracilis tendon subjects. An increased hamstring antagonist torque generated by the more functional ACLD subjects, reflective of increased hamstring contractile force, is thought to represent a protective mechanism to compensate for mechanical instability. The restoration of anterior knee stability through ACLR negates the need for augmented hamstring antagonist torque.
[Total knee arthroplasty in 2014 : Results, expectations, and complications].
Matziolis, G; Röhner, E
2015-04-01
Aseptic loosening seems to have become a minor problem in total knee arthroplasty. In contrast to that, new challenges are defined by changing patients' expectations. Beside reduction of pain and improving mobility, modern implants should not be noticed as such and should not limit sports activities. In this paper, a summary of the development and the current situation of total knee arthroplasty (e.g., implantation numbers, hospitality, operation time, and infection rates) are provided. The data are compared in an international context. In addition, current trends and developments from recent years are shown and rated according to the literature. The paper is based on a literature search (PubMed) and analyses of published official statistical data and expert recommendations. Implantation numbers have been declining gradually in Germany since 2009. In 2013, 127,077 total knee arthroplasties were implanted. In contrast, the number of revision operations has increased gradually during the last decade. In addition, hospital stay and operation time have declined. The development of implants, instruments, and operation techniques results from changing patients' expectations. All innovations must be compared against the results of well-proven techniques. The arthroplasty register may be an instrument to evaluate the results of new techniques and implants in a broad clinical application in terms of survival.
Chagas-Neto, Francisco A; Taneja, Atul K; Gregio-Junior, Everaldo; Nogueira-Barbosa, Marcello H
2017-06-01
This study aims to describe a technique for in-plane ultrasound-guided knee arthrography through a lateral suprapatellar approach, reporting its accuracy and related complications. A retrospective search was performed for computed tomography and magnetic resonance reports from June 2013 through June 2015. Imaging studies, puncture descriptions, and guided-procedure images were reviewed along with clinical and surgical history. A fellowship-trained musculoskeletal radiologist performed all procedures under sterile technique and ultrasound guidance with the probe in oblique position on the lateral suprapatellar recess after local anesthesia with the patient on dorsal decubitus, hip in neutral rotation, and 30 to 45 degrees of knee flexion. A total of 86 consecutive subjects were evaluated (mean, 55 years). All subjects underwent intra-articular injection of contrast, which was successfully reached in the first attempt in 94.2% of the procedures (81/86), and in the second attempt in 5.8% (5/86) after needle repositioning without a second puncture. There were no postprocedural reports of regional complications at the puncture site, such as significant pain, bleeding, or vascular lesions. Our study demonstrates that in-plane ultrasound-guided injection of the knee in semiflexion approaching the lateral suprapatellar recess is a safe and useful technique to administer intra-articular contrast solution, as an alternative method without radiation exposure.
Predictive Simulations of Neuromuscular Coordination and Joint-Contact Loading in Human Gait.
Lin, Yi-Chung; Walter, Jonathan P; Pandy, Marcus G
2018-04-18
We implemented direct collocation on a full-body neuromusculoskeletal model to calculate muscle forces, ground reaction forces and knee contact loading simultaneously for one cycle of human gait. A data-tracking collocation problem was solved for walking at the normal speed to establish the practicality of incorporating a 3D model of articular contact and a model of foot-ground interaction explicitly in a dynamic optimization simulation. The data-tracking solution then was used as an initial guess to solve predictive collocation problems, where novel patterns of movement were generated for walking at slow and fast speeds, independent of experimental data. The data-tracking solutions accurately reproduced joint motion, ground forces and knee contact loads measured for two total knee arthroplasty patients walking at their preferred speeds. RMS errors in joint kinematics were < 2.0° for rotations and < 0.3 cm for translations while errors in the model-computed ground-reaction and knee-contact forces were < 0.07 BW and < 0.4 BW, respectively. The predictive solutions were also consistent with joint kinematics, ground forces, knee contact loads and muscle activation patterns measured for slow and fast walking. The results demonstrate the feasibility of performing computationally-efficient, predictive, dynamic optimization simulations of movement using full-body, muscle-actuated models with realistic representations of joint function.
Current surgical strategies for total arthroplasty in valgus knee
Nikolopoulos, Dimitrios; Michos, Ioannis; Safos, George; Safos, Petros
2015-01-01
The majority of orthopaedic surgeons even currently agree that primary total arthroplasty in valgus knees with a deformity of more than ten degrees may prove challenging. The unique sets of bone and soft tissue abnormalities that must be addressed at the time of the operation make accurate axis restoration, component orientation and joint stability attainment a difficult task. Understanding the specific pathologic anatomic changes associated with the valgus knee is a prerequisite so as to select the proper surgical method, to optimize component position and restore soft-tissue balance. The purpose of this article is to review the valgus knee anatomical variations, to assess the best pre-operative planning and to evaluate how to choose the grade of constraint of the implant. It will also be underlying the up-to-date main approaches and surgical techniques be proposed in the English literature both for bone cuts and soft tissue management of valgus knees. PMID:26191494
Meneghini, Robert M; Ziemba-Davis, Mary M; Lovro, Luke R; Ireland, Phillip H; Damer, Brent M
2016-10-01
The optimal "target" ligament balance for each patient undergoing total knee arthroplasty (TKA) remains unknown. The study purpose was to determine if patient outcomes are affected by intraoperative ligament balance measured with force-sensing implant trials and if an optimal "target" balance exists. A multicenter, retrospective study reviewed consecutive TKAs performed by 3 surgeons. TKA's were performed with standard surgical techniques and ligament releases. After final implants were made, sensor-embedded smart tibial trials were inserted, and compartment forces recorded throughout the range of motion. Clinical outcome measures were obtained preoperatively and at 4 months. Statistical analysis correlated ligament balance with clinical outcomes. One hundred eighty-nine consecutive TKAs were analyzed. Patients were grouped by average medial and lateral compartment force differences. Twenty-nine TKAs (15%) were balanced within 15 lbs and 53 (28%) were "balanced" greater than 75 lbs. Greater improvement in University of California Los Angeles activity level was associated with a mediolateral force difference <60 lbs. (P = .006). Knee Society objective, function, and satisfaction scores, and self-reported health state were unrelated to mediolateral balance in the knee. Intraoperative force-sensing has potential in providing real-time objective data to optimize TKA outcomes. These data support some early outcomes may improve by balancing TKAs within 60 lbs difference. Close follow-up is warranted to determine if gait pattern adaptations affect longer term outcomes with greater or less ligament "imbalance." Copyright © 2016 Elsevier Inc. All rights reserved.
Koelewijn, Anne D; van den Bogert, Antonie J
2016-09-01
Despite having a fully functional knee and hip in both legs, asymmetries in joint moments of the knee and hip are often seen in gait of persons with a unilateral transtibial amputation (TTA), possibly resulting in excessive joint loading. We hypothesize that persons with a TTA can walk with more symmetric joint moments at the cost of increased effort or abnormal kinematics. The hypothesis was tested using predictive simulations of gait. Open loop controls of one gait cycle were found by solving an optimization problem that minimizes a combination of walking effort and tracking error in joint angles, ground reaction force and gait cycle duration. A second objective was added to penalize joint moment asymmetry, creating a multi-objective optimization problem. A Pareto front was constructed by changing the weights of the objectives and three solutions were analyzed to study the effect of increasing joint moment symmetry. When the optimization placed more weight on moment symmetry, walking effort increased and kinematics became less normal, confirming the hypothesis. TTA gait improved with a moderate increase in joint moment symmetry. At a small cost of effort and abnormal kinematics, the peak hip extension moment in the intact leg was decreased significantly, and so was the joint contact force in the knee and hip. Additional symmetry required a significant increase in walking effort and the joint contact forces in both hips became significantly higher than in able-bodied gait. Copyright © 2016 Elsevier B.V. All rights reserved.
Stevens, Peter M; Gililland, Jeremy M; Anderson, Lucas A; Mickelson, Jennifer B; Nielson, Jenifer; Klatt, Joshua W
2014-04-01
Torsional deformities of the femur and/or tibia often go unrecognized in adolescents and adults who present with anterior knee pain, and patellar maltracking or instability. While open and arthroscopic surgical techniques have evolved to address these problems, unrecognized torsion may compromise the outcomes of these procedures. We collected a group of 16 consecutive patients (23 knees), with mean age of 17, who had undergone knee surgery before torsion was recognized and subsequently treated by means of rotational osteotomy of the tibia and/or femur. By follow-up questionnaire, we sought to determine the role of rotational correction at mean 59-month follow-up. We reasoned that, by correcting torsional alignment, we might be able to optimize long-term outcomes and avert repeated knee surgery. Knee pain was significantly improved after torsional treatment (mean 8.6 pre-op vs. 3.3 post-op, p < 0.001), while 70 % of patients did have some continued knee pain postoperatively. Only 43 % of patients had continued patellar instability, and 57 % could trust their knee after surgery. Activity level remained the same or increased in 78 % of patients after torsional treatment. Excluding planned rod removal, subsequent knee surgery for continued anterior knee pain was undertaken on only 3 knees in 2 patients. We believe that malrotation of the lower limb not only raises the propensity for anterior knee symptoms, but is also a under-recognized etiology in the failure of surgeries for anterior knee pain and patellar instability. Addressing rotational abnormalities in the index surgery yields better clinical outcomes than osteotomies performed after other prior knee surgeries.
Miyamoto, N; Hirata, K; Kanehisa, H
2017-01-01
The purpose of this study was to examine whether the effects of hamstring stretching on the passive stiffness of each of the long head of the biceps femoris (BFl), semitendinosus (ST), and semimembranosus (SM) vary between passive knee extension and hip flexion stretching maneuvers. In 12 male subjects, before and after five sets of 90 s static stretching, passive lengthening measurements where knee or hip joint was passively rotated to the maximal range of motion (ROM) were performed. During the passive lengthening, shear modulus of each muscle was measured by ultrasound shear wave elastography. Both stretching maneuvers significantly increased maximal ROM and decreased passive torque at a given joint angle. Passive knee extension stretching maneuver significantly reduced shear modulus at a given knee joint angle in all of BFl, ST, and SM. In contrast, the stretching effect by passive hip flexion maneuver was significant only in ST and SM. The present findings indicate that the effects of hamstring stretching on individual passive muscles' stiffness vary between passive knee extension and hip flexion stretching maneuvers. In terms of reducing the muscle stiffness of BFl, stretching of the hamstring should be performed by passive knee extension rather than hip flexion. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Chen, Yanping; Chen, Yisha; Yan, Huangping; Wang, Xiaoling
2017-01-01
Early detection of knee osteoarthritis (KOA) is meaningful to delay or prevent the onset of osteoarthritis. In consideration of structural complexity of knee joint, position of light incidence and detector appears to be extremely important in optical inspection. In this paper, the propagation of 780-nm near infrared photons in three-dimensional knee joint model is simulated by Monte Carlo (MC) method. Six light incident locations are chosen in total to analyze the influence of incident and detecting location on the number of detected signal photons and signal to noise ratio (SNR). Firstly, a three-dimensional photon propagation model of knee joint is reconstructed based on CT images. Then, MC simulation is performed to study the propagation of photons in three-dimensional knee joint model. Photons which finally migrate out of knee joint surface are numerically analyzed. By analyzing the number of signal photons and SNR from the six given incident locations, the optimal incident and detecting location is defined. Finally, a series of phantom experiments are conducted to verify the simulation results. According to the simulation and phantom experiments results, the best incident location is near the right side of meniscus at the rear end of left knee joint and the detector is supposed to be set near patella, correspondingly.
Lateral trunk lean and medializing the knee as gait strategies for knee osteoarthritis.
Gerbrands, T A; Pisters, M F; Theeven, P J R; Verschueren, S; Vanwanseele, B
2017-01-01
To determine (1) if Medial Thrust or Trunk Lean reduces the knee adduction moment (EKAM) the most during gait in patients with medial knee osteoarthritis, (2) if the best overall strategy is the most effective for each patient and (3) if these strategies affect ankle and hip kinetics. Thirty patients with symptomatic medial knee osteoarthritis underwent 3-dimensional gait analysis. Participants received verbal instructions on two gait strategies (Trunk Lean and Medial Thrust) in randomized order after comfortable walking was recorded. The peaks and impulse of the EKAM and strategy-specific kinematic and kinetic variables were calculated for all conditions. Early stance EKAM peak was significantly reduced during Medial Thrust (-29%). During Trunk Lean, early and late stance EKAM peak and EKAM impulse reduced significantly (38%, 21% and -25%, respectively). In 79% of the subjects, the Trunk Lean condition was significantly more effective in reducing EKAM peak than Medial Thrust. Peak ankle dorsi and plantar flexion, knee flexion and hip extension and adduction moments were not significantly increased. Medial Thrust and Trunk Lean reduced the EKAM during gait in patients with knee osteoarthritis. Individual selection of the most effective gait modification strategy seems vital to optimally reduce dynamic knee loading during gait. No detrimental effects on external ankle and hip moments or knee flexion moments were found for these conditions. Copyright © 2016 Elsevier B.V. All rights reserved.
Allan, Richard; Woodburn, James; Telfer, Scott; Abbott, Mandy; Steultjens, Martijn Pm
2017-06-01
The knee adduction moment is consistently used as a surrogate measure of medial compartment loading. Foot orthoses are designed to reduce knee adduction moment via lateral wedging. The 'dose' of wedging required to optimally unload the affected compartment is unknown and variable between individuals. This study explores a personalised approach via three-dimensional printed foot orthotics to assess the biomechanical response when two design variables are altered: orthotic length and lateral wedging. Foot orthoses were created for 10 individuals with symptomatic medial knee osteoarthritis and 10 controls. Computer-aided design software was used to design four full and four three-quarter-length foot orthoses per participant each with lateral posting of 0° 'neutral', 5° rearfoot, 10° rearfoot and 5° forefoot/10° rearfoot. Three-dimensional printers were used to manufacture all foot orthoses. Three-dimensional gait analyses were performed and selected knee kinetics were analysed: first peak knee adduction moment, second peak knee adduction moment, first knee flexion moment and knee adduction moment impulse. Full-length foot orthoses provided greater reductions in first peak knee adduction moment (p = 0.038), second peak knee adduction moment (p = 0.018) and knee adduction moment impulse (p = 0.022) compared to three-quarter-length foot orthoses. Dose effect of lateral wedging was found for first peak knee adduction moment (p < 0.001), second peak knee adduction moment (p < 0.001) and knee adduction moment impulse (p < 0.001) indicating greater unloading for higher wedging angles. Significant interaction effects were found for foot orthosis length and participant group in second peak knee adduction moment (p = 0.028) and knee adduction moment impulse (p = 0.036). Significant interaction effects were found between orthotic length and wedging condition for second peak knee adduction moment (p = 0.002). No significant changes in first knee flexion moment were found. Individual heterogeneous responses to foot orthosis conditions were observed for first peak knee adduction moment, second peak knee adduction moment and knee adduction moment impulse. Biomechanical response is highly variable with personalised foot orthoses. Findings indicate that the tailoring of a personalised intervention could provide an additional benefit over standard interventions and that a three-dimensional printing approach to foot orthosis manufacturing is a viable alternative to the standard methods.
Eliminating impingement optimizes patellar biomechanics in high knee flexion.
Tang, Qi-heng; Zhou, Yi-xin; Tang, Jing; Shao, Hong-yi; Wang, Guang-zhi
2010-08-01
We investigated the impact of eliminating the impingement between extensor mechanism and tibial insert on patellar tracking and patellar ligament tension in high knee flexion. Six cadaveric specimens were tested on an Oxford-type testing rig. The Genesis II knee system was implanted into each specimen knee with the traditional tibial insert and high-flex insert successively. Compared to traditional insert, the high-flex insert was characterized with a chambered anterior post and a chambered anterior lip which eliminates patella-post and patellar ligament-anterior lip impingements. The patella was tracked with an NDI Optotrak Certus system. The patellar ligament tension was measured using a NKB S-type tension transducer. There was a decrease of resultant patellar translation relative to the femur with statistically significant (P<0.05) at 90 degrees to 150 degrees of knee flexion and a decrease of patellar ligament tension with statistical significance (P<0.05) at 100 degrees, 120 degrees, 130 degrees, and 140 degrees of flexion using high-flex insert compared to traditional insert. Eliminating the impingement between extensor mechanism and implant in high knee flexion altered patellar tracking and reduced patellar ligament tension, which would facilitate high knee flexion.
The knee: Surface-coil MR imaging at 1. 5 T
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beltran, J.; Noto, A.M.; Mosure, J.C.
1986-06-01
Seven normal knees (in five volunteers) and seven injured knees (in seven patients) were examined by high-resolution magnetic resonance (MR) imaging at 1.5 T with a surface coil. Seven medial meniscal tears, three anterior cruciate ligament tears, one posterior cruciate ligament avulsion, an old osteochondral fracture, femoral condylar chondro-malacia, and one case of semimembranous tendon reinsertion were identified. MR images correlated well with recent double-contrast arthrograms or results of surgery. All tears were identified in both the sagittal and coronal planes. Because of its ability to demonstrate small meniscal lesions and ligamentous injuries readily, MR imaging with a surface coilmore » may eventually replace the more invasive arthrography.« less
Clinical Outcome and Return to Competition after Microfracture in the Athlete’s Knee
Mithoefer, Kai; Gill, Thomas J.; Cole, Brian J.; Williams, Riley J.; Mandelbaum, Bert R.
2010-01-01
Microfracture is frequently used for articular cartilage repair in athletes. This study aimed to define the strength and weaknesses of this minimally invasive cartilage repair technique in the athletic population in an effort to optimize indications, functional outcome, and athletic participation after microfracture in the athlete’s knee. A systematic analysis of original studies using microfracture in athletes was performed. Functional outcome was assessed by activity outcome scores, ability to return to sports participation, timing of the return to sport, level of postoperative sports activity, and continuation of athletic competition over time. Thirteen studies describing 821 athletes were included in the analysis with an average follow-up of 42 months. Good or excellent results were reported in 67% of athletes with normal International Knee Documentation Committee (IKDC) scores in 80% and significant increase of Lysholm scores, Tegner activity scores, and Knee injury and Osteoarthritis Outcome Score (KOOS) sports subscales. Return to sports was achieved in 66% at an average of 8 months after surgery, with return to competition at the preinjury level in 67%. Forty-nine percent of athletes continued to compete without change in level of play, while decreasing function was observed in 42% after 2 to 5 years. Athlete’s age, preoperative duration of symptoms, level of play, lesion size, and repair tissue morphology affected sports activity after microfracture. Microfracture improves knee function and frequently allows for return to sports at the preinjury level, but deterioration of athletic function occurs in some patients. Several independent factors were identified that can help to optimize the return to athletic competition after microfracture in the athlete’s knee. PMID:26069542
Design and testing of a regenerative magnetorheological actuator for assistive knee braces
NASA Astrophysics Data System (ADS)
Ma, Hao; Chen, Bing; Qin, Ling; Liao, Wei-Hsin
2017-03-01
In this paper, a multifunctional magneto-rheological actuator with power regeneration capability, named regenerative magnetorheological actuator (RMRA), is designed for gait assistance in the knee joint. RMRA has motor and magnetorheological (MR) brake parts working in parallel that can harvest energy through regenerative braking. This novel design provides multiple functions with good energy efficiency. The configuration and basic design of the RMRA are first introduced. Then geometrical optimization of the MR brake is conducted based on a parameterized model, and multiple factors are considered in the design objectives: braking torque, weight, and power consumption. After the optimal design is obtained, an RMRA prototype is fabricated and associated driver circuits are designed. Finally, multiple functions of the RMRA, especially three different braking modes, are modeled and tested. Experimental results of RMRA output performances in all working modes match the modeling and simulation. Assistive knee braces with the developed RMRA are promising for future applications in gait assistance and rehabilitation.
Knee cartilage extraction and bone-cartilage interface analysis from 3D MRI data sets
NASA Astrophysics Data System (ADS)
Tamez-Pena, Jose G.; Barbu-McInnis, Monica; Totterman, Saara
2004-05-01
This works presents a robust methodology for the analysis of the knee joint cartilage and the knee bone-cartilage interface from fused MRI sets. The proposed approach starts by fusing a set of two 3D MR images the knee. Although the proposed method is not pulse sequence dependent, the first sequence should be programmed to achieve good contrast between bone and cartilage. The recommended second pulse sequence is one that maximizes the contrast between cartilage and surrounding soft tissues. Once both pulse sequences are fused, the proposed bone-cartilage analysis is done in four major steps. First, an unsupervised segmentation algorithm is used to extract the femur, the tibia, and the patella. Second, a knowledge based feature extraction algorithm is used to extract the femoral, tibia and patellar cartilages. Third, a trained user corrects cartilage miss-classifications done by the automated extracted cartilage. Finally, the final segmentation is the revisited using an unsupervised MAP voxel relaxation algorithm. This final segmentation has the property that includes the extracted bone tissue as well as all the cartilage tissue. This is an improvement over previous approaches where only the cartilage was segmented. Furthermore, this approach yields very reproducible segmentation results in a set of scan-rescan experiments. When these segmentations were coupled with a partial volume compensated surface extraction algorithm the volume, area, thickness measurements shows precisions around 2.6%
Wang, Yuanyuan; Wluka, Anita E; Berry, Patricia A; Siew, Terence; Teichtahl, Andrew J; Urquhart, Donna M; Lloyd, David G; Jones, Graeme; Cicuttini, Flavia M
2012-12-01
Although there is evidence for a beneficial effect of increased quadriceps strength on knee symptoms, the effect on knee structure is unclear. We undertook this study to examine the relationship between change in vastus medialis cross-sectional area (CSA) and knee pain, tibial cartilage volume, and risk of knee replacement in subjects with symptomatic knee osteoarthritis (OA). One hundred seventeen subjects with symptomatic knee OA underwent magnetic resonance imaging of the knee at baseline and at 2 and 4.5 years. Vastus medialis CSA was measured at baseline and at 2 years. Tibial cartilage volume was measured at baseline and at 2 and 4.5 years. Knee pain was assessed by the Western Ontario and McMaster Universities Osteoarthritis Index at baseline and at 2 years. The frequency of knee joint replacement over 4 years was determined. Regression coefficients (B) and odds ratios were determined along with 95% confidence intervals (95% CIs). After adjusting for confounders, baseline vastus medialis CSA was inversely associated with current knee pain (r = -0.16, P = 0.04) and with medial tibial cartilage volume loss from baseline to 2 years (B coefficient -10.9 [95% CI -19.5, -2.3]), but not with baseline tibial cartilage volume. In addition, an increase in vastus medialis CSA from baseline to 2 years was associated with reduced knee pain over the same time period (r = 0.24, P = 0.007), reduced medial tibial cartilage loss from 2 to 4.5 years (B coefficient -16.8 [95% CI -28.9, -4.6]), and reduced risk of knee replacement over 4 years (odds ratio 0.61 [95% CI 0.40, 0.94]). In a population of patients with symptomatic knee OA, increased vastus medialis size was associated with reduced knee pain and beneficial structural changes at the knee, suggesting that management of knee pain and optimizing vastus medialis size are important in reducing OA progression and subsequent knee replacement. Copyright © 2012 by the American College of Rheumatology.
Patient experience in fast-track hip and knee arthroplasty--a qualitative study.
Specht, Kirsten; Kjaersgaard-Andersen, Per; Pedersen, Birthe D
2016-03-01
To explore the lived experience of patients in fast-track primary unilateral total hip and knee arthroplasty from the first visit at the outpatient clinic until discharge. Fast-track has resulted in increased effectiveness, including faster recovery and shorter length of stay to about two days after hip and knee arthroplasty. However, the patient perspective in fast-track with a median length of stay of less than three days has been less investigated. A qualitative design. A phenomenological-hermeneutic approach was used, inspired by Paul Ricoeur's theory of narrative and interpretation. Eight patients were included. Semi-structured interviews and participant observation were performed. Three themes emerged: dealing with pain; feelings of confidence or uncertainty - the meaning of information; and readiness for discharge. Generally, the patients were resistant to taking analgesics and found it difficult to find out when to take supplementary analgesics; therefore, nursing staff needed enough expertise to take responsibility. Factors that increased patients' confidence: information about fast-track, meeting staff before admission and involving relatives. In contrast, incorrect or conflicting information and a lack of respect for privacy led to uncertainty. In preparing for early discharge, sufficient pain management, feeling well-rested and optimal use of time during hospitalisation were important. The study shows the importance of dealing with pain and getting the right information and support to have confidence in the fast-track programme, to be ready for discharge and to manage postoperatively at home. In fast-track focusing on early discharge, there is an increased need for evidence-based nursing practice, including a qualified judgement of what is best for the patient in certain situations. The knowledge should be gleaned from: research; the patients' expertise, understanding and situation; and nurses' knowledge, skills and experience. © 2015 John Wiley & Sons Ltd.
Lee, Chan-Bok; Eun, Denny; Kim, Kang-Ho; Park, Jae-Wan; Jee, Yong-Seok
2017-01-01
Most protocols for testing and rehabilitation for recovery and improvement of muscular endurance have been set at 180°/sec, 240°/sec, and 300°/sec. These protocols can cause confusion to clinical providers or other researchers. This study was aimed at investigating the optimal isokinetic angular speed for measuring or developing muscular endurance after assessing the relationship between cardiopulmonary responses and isokinetic moments. This study was conducted with 31 male and female college students. Graded exercise test and body composition were measured as well as the isokinetic moments of the knee muscles at three angular speeds: 180°/sec, 240°/sec, and 300°/sec. The specific isokinetic moments of knee muscles that were measured included: peak torque (PT) and total work (TW) on extensor (e) and flexor (f) of knee joints, which were denoted as ePT180, fPT180, eTW180, fTW180, ePT240, fPT240, eTW240, fTW240, ePT300, fPT300, eTW300, and fTW300 according to the three angular speeds. Spearman correlation test was used to examine the relationship between the sum means of cardiopulmonary responses and the variables of isokinetic moments. This study confirmed that the optimal angular speed for testing or training for muscular endurance was 180°/sec, which showed a stronger relationship between cardiopulmonary responses and isokinetic moments. Therefore, this angular speed is recommended for testing and training for muscular endurance of the knee joints. PMID:28503531
Lee, Chan-Bok; Eun, Denny; Kim, Kang-Ho; Park, Jae-Wan; Jee, Yong-Seok
2017-04-01
Most protocols for testing and rehabilitation for recovery and improvement of muscular endurance have been set at 180°/sec, 240°/sec, and 300°/sec. These protocols can cause confusion to clinical providers or other researchers. This study was aimed at investigating the optimal isokinetic angular speed for measuring or developing muscular endurance after assessing the relationship between cardiopulmonary responses and isokinetic moments. This study was conducted with 31 male and female college students. Graded exercise test and body composition were measured as well as the isokinetic moments of the knee muscles at three angular speeds: 180°/sec, 240°/sec, and 300°/sec. The specific isokinetic moments of knee muscles that were measured included: peak torque (PT) and total work (TW) on extensor (e) and flexor (f) of knee joints, which were denoted as ePT180, fPT180, eTW180, fTW180, ePT240, fPT240, eTW240, fTW240, ePT300, fPT300, eTW300, and fTW300 according to the three angular speeds. Spearman correlation test was used to examine the relationship between the sum means of cardiopulmonary responses and the variables of isokinetic moments. This study confirmed that the optimal angular speed for testing or training for muscular endurance was 180°/sec, which showed a stronger relationship between cardiopulmonary responses and isokinetic moments. Therefore, this angular speed is recommended for testing and training for muscular endurance of the knee joints.
Bae, Tae Soo; Loan, Peter; Choi, Kuiwon; Hong, Daehie; Mun, Mu Seong
2010-12-01
When car crash experiments are performed using cadavers or dummies, the active muscles' reaction on crash situations cannot be observed. The aim of this study is to estimate muscles' response of the major muscle groups using three-dimensional musculoskeletal model by dynamic simulations of low-speed sled-impact. The three-dimensional musculoskeletal models of eight subjects were developed, including 241 degrees of freedom and 86 muscles. The muscle parameters considering limb lengths and the force-generating properties of the muscles were redefined by optimization to fit for each subject. Kinematic data and external forces measured by motion tracking system and dynamometer were then input as boundary conditions. Through a least-squares optimization algorithm, active muscles' responses were calculated during inverse dynamic analysis tracking the motion of each subject. Electromyography for major muscles at elbow, knee, and ankle joints was measured to validate each model. For low-speed sled-impact crash, experiment and simulation with optimized and unoptimized muscle parameters were performed at 9.4 m/h and 10 m/h and muscle activities were compared among them. The muscle activities with optimized parameters were closer to experimental measurements than the results without optimization. In addition, the extensor muscle activities at knee, ankle, and elbow joint were found considerably at impact time, unlike previous studies using cadaver or dummies. This study demonstrated the need to optimize the muscle parameters to predict impact situation correctly in computational studies using musculoskeletal models. And to improve accuracy of analysis for car crash injury using humanlike dummies, muscle reflex function, major extensor muscles' response at elbow, knee, and ankle joints, should be considered.
Preoperative planning and perioperative management for minimally invasive total knee arthroplasty.
Scuderi, Giles R
2006-07-01
The introduction of minimally invasive surgery (MIS) has led to new clinical pathways for total knee arthroplasty (TKA). MIS TKA outcomes are affected by multiple factors--the surgery itself; preoperative planning and medical management; preoperative patient education; preemptive perioperative and postoperative analgesia; mode of anesthesia; optimal rehabilitation; and enlightened home care and social services-and therefore an integrated team approach to patient and surgery is required.
Ready to Use Tissue Construct for Military Bone & Cartilage Trauma
2014-10-01
during nail introduction and reaming. In the present study, we examined the load - bearing capacity and optimal internal fixation of a bone/poly-ε...segmental defect, (a) axial loading via ball bearing , (b) torsional loading via square clamp allowing axial displacement, (c) three-point bending of tibia...knee joints by simulating loads seen during ambulation and knee range of motion. Our central hypothesis is that an anatomically and
Accuracy of Patient Specific Cutting Blocks in Total Knee Arthroplasty
Helmy, Naeder; Kühnel, Stefanie P.
2014-01-01
Background. Long-term survival of total knee arthroplasty (TKA) is mainly determined by optimal positioning of the components and prosthesis alignment. Implant positioning can be optimized by computer assisted surgery (CAS). Patient specific cutting blocks (PSCB) seem to have the potential to improve component alignment compared to the conventional technique and to be comparable to CAS. Methods. 113 knees were selected for PSI and included in this study. Pre- and postoperative mechanical axis, represented by the hip-knee-angle (HKA), the proximal tibial angle (PTA), the distal femoral angle (DFA), and the tibial slope (TS) were measured and the deviation from expected ideal values was calculated. Results. With a margin of error of ±3°, success rates were 81.4% for HKA, 92.0% for TPA, and 94.7% for DFA. With the margin of error for alignments extended to ±4°, we obtained a success rate of 92.9% for the HKA, 98.2% for the PTA, and 99.1% for the DFA. The TS showed postoperative results of 2.86 ± 2.02° (mean change 1.76 ± 2.85°). Conclusion. PSCBs for TKA seem to restore the overall leg alignment. Our data suggest that each individual component can be implanted accurately and the results are comparable to the ones in CAS. PMID:25254210
Bedard, Nicholas A; Dowdle, Spencer B; Anthony, Christopher A; DeMik, David E; McHugh, Michael A; Bozic, Kevin J; Callaghan, John J
2017-09-01
Despite American Academy of Orthopaedic Surgeons Clinical Practice Guidelines (CPGs) related to the non-arthroplasty management of osteoarthritis (OA) of the knee, non-recommended treatments remain in common use. We sought to determine the costs associated with non-arthroplasty management of knee OA in the year prior to total knee arthroplasty (TKA) and stratify them by CPG recommendation status. The Humana database was reviewed from 2007 to 2015 for primary TKA patients. Costs for hyaluronic acid (HA) and corticosteroid injections, physical therapy, braces, wedge insoles, opioids, non-steroidal anti-inflammatories, and tramadol in the year prior to TKA were calculated. Cost was defined as reimbursement paid by the insurance provider. Costs were analyzed relative to the overall non-inpatient costs for knee OA and categorized based on CPG recommendations. In total 86,081 primary TKA patients were analyzed and 65.8% had at least one treatment in the year prior to TKA. Treatments analyzed made up 57.6% of the total non-inpatient cost of knee OA in the year prior to TKA. Only 3 of the 8 treatments studied have a strong recommendation for their use (physical therapy, non-steroidal anti-inflammatories, tramadol) and costs for these interventions represented 12.2% of non-inpatient knee OA cost. In contrast, 29.3% of the costs are due to HA injections alone, which are not supported by CPGs. In the year prior to TKA, over half of the non-inpatient costs associated with knee OA are from injections, therapy, prosthetics, and prescriptions. Approximately 30% of this is due to HA injections alone. If only interventions recommend by the CPG are utilized then costs associated with knee OA could be decreased by 45%. Copyright © 2017 Elsevier Inc. All rights reserved.
The Oxford unicompartmental knee fails at a high rate in a high-volume knee practice.
Schroer, William C; Barnes, C Lowry; Diesfeld, Paul; LeMarr, Angela; Ingrassia, Rachel; Morton, Diane J; Reedy, Mary
2013-11-01
The Oxford knee is a unicompartmental implant featuring a mobile-bearing polyethylene component with excellent long-term survivorship results reported by the implant developers and early adopters. By contrast, other studies have reported higher revision rates in large academic practices and in national registries. Registry data have shown increased failure with this implant especially by lower-volume surgeons and institutions. In the setting of a high-volume knee arthroplasty practice, we sought to determine (1) the failure rate of the Oxford unicompartmental knee implant using a failure definition for aseptic loosening that combined clinical features, plain radiographs, and scintigraphy, and (2) whether increased experience with this implant would decrease failure rate, if there is a learning curve effect. Eighty-three Oxford knee prostheses were implanted between September 2005 and July 2008 by the principal investigator. Radiographic and clinical data were available for review for all cases. A failed knee was defined as having recurrent pain after an earlier period of recovery from surgery, progressive radiolucent lines compared with initial postoperative radiographs, and a bone scan showing an isolated area of uptake limited to the area of the replaced compartment. Eleven knees in this series failed (13%); Kaplan-Meier survivorship was 86.5% (95% CI, 78.0%-95.0%) at 5 years. Failure occurrences were distributed evenly over the course of the study period. No learning curve effect was identified. Based on these findings, including a high failure rate of the Oxford knee implant and the absence of any discernible learning curve effect, the principal investigator no longer uses this implant.
Suh, J S; Cho, J H; Shin, K H; Kim, S J
1996-01-01
Twenty-one MRI studies with a fat-suppression three-dimensional spoiled gradient-recalled echo in a steady state (3D SPGR) pulse sequence after intravenous contrast injection were evaluated to assess the accuracy in depicting chondromalacia of the knee. On the basis of MR images, chondromalacia and its grade were determined in each of five articular cartilage regions (total, 105 regions) and then the results were compared to arthroscopic findings. The sensitivity, specificity, and accuracy of MRI were 70%, 99%, and 93%, respectively. MR images depicted 7 of 11 lesions of arthroscopic grade 1 or 2 chondromalacia, and seven of nine lesions of arthroscopic grade 3 or 4 chondromalacia. The cartilage abnormalities in all cases appeared as focal lesions with high signal intensity. Intravenous contrast-injection, fat-suppression 3D SPGR imaging showed high specificity in excluding cartilage abnormalities and may be considered as an alternative to intra-articular MR arthrography when chondromalacia is suspected.
Gadolinium-enhanced MR images of the growing piglet skeleton: ionic versus nonionic contrast agent.
Menezes, Nina M; Olear, Elizabeth A; Li, Xiaoming; Connolly, Susan A; Zurakowski, David; Foley, Mary; Shapiro, Frederic; Jaramillo, Diego
2006-05-01
To determine whether there are differences in the distribution of ionic and nonionic gadolinium-based contrast agents by evaluating contrast enhancement of the physis, epiphyseal cartilage, secondary ossification center, and metaphysis in the knees of normal piglets. Following approval from the Subcommittee on Research Animal Care, knees of 12 3-week-old piglets were imaged at 3-T magnetic resonance (MR) imaging after intravenous injection of gadoteridol (nonionic contrast agent; n = 6) or gadopentetate dimeglumine (ionic contrast agent; n = 6). Early enhancement evaluation with gradient-echo MR imaging was quantified and compared (Student t test) by means of enhancement ratios. Distribution of contrast material was assessed and compared (Student t test) by means of T1 measurements obtained before and at three 15-minute intervals after contrast agent administration. The relative visibility of the physis, epiphyseal cartilage, secondary ossification center, and metaphysis was qualitatively assessed by two observers and compared (Wilcoxon signed rank test). Differences in matrix content and cellularity that might explain the imaging findings were studied at histologic evaluation. Enhancement ratios were significantly higher for gadoteridol than for gadopentetate dimeglumine in the physis, epiphyseal cartilage, and secondary ossification center (P < .05). After contrast agent administration, T1 values decreased sharply for both agents-but more so for gadoteridol. Additionally, there was less variability in T1 values across structures with this contrast agent. Gadoteridol resulted in greater visibility of the physis, while gadopentetate dimeglumine resulted in greater contrast between the physis and metaphysis (P < .05). The results suggest different roles for the two gadolinium-based contrast agents: The nonionic contrast medium is better suited for evaluating perfusion and anatomic definition in the immature skeleton, while the ionic contrast medium is better for evaluating cartilage fixed-charge density. (c) RSNA, 2006.
[Modern unicondylar knee arthroplasty. Tips and tricks].
von Knoch, F; Munzinger, U
2014-05-01
Unicondylar knee arthroplasty (UKA) is an established therapeutic option for advanced medial or lateral gonarthrosis. The cornerstones of a successful UKA, careful patient selection, preoperative planning and precise operation technique, are discussed in this overview article. In contrast to total knee arthroplasty, UKA allows preservation of the contralateral and patellofemoral compartments as well as the cruciate ligaments and is often associated with rapid postoperative recovery, improved knee kinematics and knee function. However, UKA is technically very demanding. High revision rates have been reported in particular with widespread application, according to national joint replacement registries. Successful UKA relies on meticulous patient selection, preoperative planning and surgical technique. It is justified to broaden classic UKA indications. In medial and lateral UKA three types of mechanical varus-valgus deformity can be encountered: type 1 (isolated intraarticular deformity), type 2 (pronounced deformity due to extraarticular varus deformity in medial UKA or valgus deformity in lateral UKA), type 3 (reduced deformity due to extraarticular valgus deformity in medial UKA or varus deformity in lateral UKA). We believe these deformities should be addressed accordingly with surgical technique.
MRI EVALUATION OF KNEE CARTILAGE
Rodrigues, Marcelo Bordalo; Camanho, Gilberto Luís
2015-01-01
Through the ability of magnetic resonance imaging (MRI) to characterize soft tissue noninvasively, it has become an excellent method for evaluating cartilage. The development of new and faster methods allowed increased resolution and contrast in evaluating chondral structure, with greater diagnostic accuracy. In addition, physiological techniques for cartilage assessment that can detect early changes before the appearance of cracks and erosion have been developed. In this updating article, the various techniques for chondral assessment using knee MRI will be discussed and demonstrated. PMID:27022562
Sosdian, L; Dobson, F; Wrigley, T V; Paterson, K; Bennell, K; Dowsey, M; Choong, P; Allison, K; Hinman, R S
2014-12-01
Knee arthroplasty (KA) is recognized as an effective treatment of knee joint osteoarthritis and up to 90% of patients experience substantial pain relief. There has been no systematic review synthesizing the longitudinal changes in gait following KA. The aims of this systematic review were to determine the effects of KA on (i) frontal plane and (ii) sagittal plane kinematic and kinetic parameters during the stance phase of gait. MEDLINE (PubMed), CINAHL, SPORTdiscus (EBSCO), and Cochrane Library (Wiley) were searched until April 10th, 2014. 1,765 articles were identified, of which 19 studies describing 3-dimensional gait analysis pre- and post-KA were included. Study quality was evaluated by two reviewers independently using the Downs and Black checklist. Following KA, in the frontal plane, the maximum knee adduction angle and external knee adduction moment (KAM) tended to decrease. In the sagittal plane, findings suggest that the maximum knee flexion moment is increased. From the ten studies that included a healthy reference group, it was unclear whether gait variables returned to normal following KA. Overall, it appears that KA results in a decreased peak KAM and maximum knee adduction angles, an increased peak knee flexion moment and inconsistent changes in the peak knee flexion angle. Knowledge gaps remain due to methodological inconsistencies across studies, limited statistical analysis, and largely heterogeneous sample populations. More research is needed to determine whether KA restores gait patterns to normal, or if additional rehabilitation may be needed to optimize gait following surgery for osteoarthritis. Copyright © 2014 Elsevier B.V. All rights reserved.
Effect of footwear on the external knee adduction moment - A systematic review.
Radzimski, Andy Oliver; Mündermann, Annegret; Sole, Gisela
2012-06-01
Footwear modifications have been investigated as conservative interventions to decrease peak external knee adduction moment (EKAM) and pain associated with knee osteoarthritis (OA). To evaluate the literature on the effect of different footwear and orthotics on the peak EKAM during walking and/or running. A systematic search of databases resulted in 348 articles of which 33 studies were included. Seventeen studies included healthy individuals and 19 studies included subjects with medial knee OA. Quality assessment (modified Downs and Black quality index) showed an (average±SD) of 73.1±10.1%. The most commonly used orthotic was the lateral wedge, with three studies on the medial wedge. Lateral wedging was associated with decreased peak EKAM in healthy participants and participants with medial knee OA while there is evidence for increased peak EKAM with the use of medial wedges. Modern footwear (subjects' own shoe, "stability" and "mobility" shoes, clogs) were likely to increase the EKAM compared to barefoot walking in individuals with medial knee OA. Walking in innovative shoes ("variable stiffness") decreased the EKAM compared to control shoes. Similarly, shoes with higher heels, sneakers and dress shoes increased EKAM in healthy individuals compared to barefoot walking. Further development may be needed toward optimal footwear for patients with medial knee OA with the aim of obtaining similar knee moments to barefoot walking. Copyright © 2011 Elsevier B.V. All rights reserved.
Wu, Kai; Liu, Jing; Wang, Shuai
2016-01-01
Evolutionary games (EG) model a common type of interactions in various complex, networked, natural and social systems. Given such a system with only profit sequences being available, reconstructing the interacting structure of EG networks is fundamental to understand and control its collective dynamics. Existing approaches used to handle this problem, such as the lasso, a convex optimization method, need a user-defined constant to control the tradeoff between the natural sparsity of networks and measurement error (the difference between observed data and simulated data). However, a shortcoming of these approaches is that it is not easy to determine these key parameters which can maximize the performance. In contrast to these approaches, we first model the EG network reconstruction problem as a multiobjective optimization problem (MOP), and then develop a framework which involves multiobjective evolutionary algorithm (MOEA), followed by solution selection based on knee regions, termed as MOEANet, to solve this MOP. We also design an effective initialization operator based on the lasso for MOEA. We apply the proposed method to reconstruct various types of synthetic and real-world networks, and the results show that our approach is effective to avoid the above parameter selecting problem and can reconstruct EG networks with high accuracy. PMID:27886244
NASA Astrophysics Data System (ADS)
Wu, Kai; Liu, Jing; Wang, Shuai
2016-11-01
Evolutionary games (EG) model a common type of interactions in various complex, networked, natural and social systems. Given such a system with only profit sequences being available, reconstructing the interacting structure of EG networks is fundamental to understand and control its collective dynamics. Existing approaches used to handle this problem, such as the lasso, a convex optimization method, need a user-defined constant to control the tradeoff between the natural sparsity of networks and measurement error (the difference between observed data and simulated data). However, a shortcoming of these approaches is that it is not easy to determine these key parameters which can maximize the performance. In contrast to these approaches, we first model the EG network reconstruction problem as a multiobjective optimization problem (MOP), and then develop a framework which involves multiobjective evolutionary algorithm (MOEA), followed by solution selection based on knee regions, termed as MOEANet, to solve this MOP. We also design an effective initialization operator based on the lasso for MOEA. We apply the proposed method to reconstruct various types of synthetic and real-world networks, and the results show that our approach is effective to avoid the above parameter selecting problem and can reconstruct EG networks with high accuracy.
Simultaneous segmentation of the bone and cartilage surfaces of a knee joint in 3D
NASA Astrophysics Data System (ADS)
Yin, Y.; Zhang, X.; Anderson, D. D.; Brown, T. D.; Hofwegen, C. Van; Sonka, M.
2009-02-01
We present a novel framework for the simultaneous segmentation of multiple interacting surfaces belonging to multiple mutually interacting objects. The method is a non-trivial extension of our previously reported optimal multi-surface segmentation. Considering an example application of knee-cartilage segmentation, the framework consists of the following main steps: 1) Shape model construction: Building a mean shape for each bone of the joint (femur, tibia, patella) from interactively segmented volumetric datasets. Using the resulting mean-shape model - identification of cartilage, non-cartilage, and transition areas on the mean-shape bone model surfaces. 2) Presegmentation: Employment of iterative optimal surface detection method to achieve approximate segmentation of individual bone surfaces. 3) Cross-object surface mapping: Detection of inter-bone equidistant separating sheets to help identify corresponding vertex pairs for all interacting surfaces. 4) Multi-object, multi-surface graph construction and final segmentation: Construction of a single multi-bone, multi-surface graph so that two surfaces (bone and cartilage) with zero and non-zero intervening distances can be detected for each bone of the joint, according to whether or not cartilage can be locally absent or present on the bone. To define inter-object relationships, corresponding vertex pairs identified using the separating sheets were interlinked in the graph. The graph optimization algorithm acted on the entire multiobject, multi-surface graph to yield a globally optimal solution. The segmentation framework was tested on 16 MR-DESS knee-joint datasets from the Osteoarthritis Initiative database. The average signed surface positioning error for the 6 detected surfaces ranged from 0.00 to 0.12 mm. When independently initialized, the signed reproducibility error of bone and cartilage segmentation ranged from 0.00 to 0.26 mm. The results showed that this framework provides robust, accurate, and reproducible segmentation of the knee joint bone and cartilage surfaces of the femur, tibia, and patella. As a general segmentation tool, the developed framework can be applied to a broad range of multi-object segmentation problems.
Song, I H; Althoff, C E; Hermann, K G; Scheel, A K; Knetsch, T; Burmester, G R; Backhaus, M
2009-01-01
To evaluate contrast-enhanced ultrasound (CE-US) as a monitoring tool to assess hypervascularisation of synovial processes in knee osteoarthritis (OA) treated with intra-articular injections of the bradykinin-receptor 2 antagonist icatibant compared to contrast-enhanced magnetic resonance imaging (CE-MRI). In a randomised, double-blind, placebo-controlled trial, 41 patients with painful knee OA underwent US (12.5 MHz for B-mode and 3-8 MHz for CE-US), and 36 of the patients underwent additional MRI (0.2T) at baseline and after 3 injections of the study drug (after a mean of 22.2 days). A total of 15 patients received placebo (group A), 12 patients 500 microg icatibant (group B) and 14 patients 2000 microg icatibant (group C). Pain and the synovial process (B-mode, power Doppler US (PD-US), CE-US, CE-MRI) were assessed at both time points. At baseline, the placebo group showed more activity in terms of effusion in the superior and lateral recess in ultrasound as well as in PD-US in the lateral recess. Pain improved significantly in all subgroups. Effect sizes were 0.43 (pain at rest) and 0.52 (pain during activity) in group B vs 0.48 and 1.11 in group C. There was no change of US and MRI parameters. We found moderate to good correlation (r) and kappa values (kappa) for effusion in the superior recess (r = 0.591, k = 0.453), effusion in the lateral recess (r = 0.304, k = 0.440) and contrast enhancement (r = 0.601, k = 0.242) between US and MRI. Our results show that CE-US and CE-MRI have good agreement in assessing inflammatory changes in knee OA. For the 41 patients with OA, an analgesic effect of icatibant could clearly be shown, especially for pain during activity in the high dose icatibant group. However, we could not find an anti-inflammatory effect of icatibant by CE-US compared to CE-MRI.
Comparison of Joint Loading in Badminton Lunging between Professional and Amateur Badminton Players
Fu, Lin
2017-01-01
The knee and ankle are the two most injured joints associated with the sport of badminton. This study evaluates biomechanical factors between professional and amateur badminton players using an injury mechanism model. The aim of this study was to investigate the kinematic motion and kinetic loading differences of the right knee and ankle while performing a maximal right lunge. Amateur players exhibited greater ankle range of motion (p < 0.05, r = 0.89) and inversion joint moment (p < 0.05, r = 0.54) in the frontal plane as well as greater internal joint rotation moment (p < 0.05, r = 0.28) in the horizontal plane. In contrast, professional badminton players presented a greater knee joint moment in the sagittal (p < 0.05, r = 0.59) and frontal (p < 0.05, r = 0.37) planes, which may be associated with increased knee ligamentous injury risk. To avoid injury, the players need to forcefully extend the knee with internal rotation, strengthen the muscles around the ankle ligament, and maximise joint coordination during training. The injuries recorded and the forces responsible for the injuries seem to have developed during training activity. Training programmes and injury prevention strategies for badminton players should account for these findings to reduce potential injury to the ankle and knee. PMID:28694684
Sánchez, Natalia; Acosta, Ana Maria; Stienen, Arno H.A.
2015-01-01
Characterization of the joint torque coupling strategies used in the lower extremity to generate maximal and submaximal levels of torque at either the hip, knee or ankle is lacking. Currently, there are no available isometric devices that quantify all concurrent joint torques in the hip, knee and ankle of a single leg during maximum voluntary torque generation. Thus, joint-torque coupling strategies in the hip, knee and concurrent torques at ankle and/or coupling patterns at the hip and knee driven by the ankle have yet to be quantified. This manuscript describes the design, implementation and validation of a multiple degree of freedom, lower extremity isometric device (the MultiLEIT) that accurately quantifies simultaneous torques at the hip, knee and ankle. The system was mechanically validated and then implemented with two healthy control individuals and two post-stroke individuals to test usability and patient acceptance. Data indicated different joint torque coupling strategies used by both healthy individuals. In contrast, data showed the same torque coupling patterns in both post-stroke individuals, comparable to those described in the clinic. Successful implementation of the MultiLEIT can contribute to the understanding of the underlying mechanisms responsible for abnormal movement patterns and aid in the design of therapeutic interventions. PMID:25163064
Bennell, Kim L; Egerton, Thorlene; Wrigley, Tim V; Hodges, Paul W; Hunt, Michael; Roos, Ewa M; Kyriakides, Mary; Metcalf, Ben; Forbes, Andrew; Ageberg, Eva; Hinman, Rana S
2011-12-05
Osteoarthritis of the knee involving predominantly the medial tibiofemoral compartment is common in older people, giving rise to pain and loss of function. Many people experience progressive worsening of the disease over time, particularly those with varus malalignment and increased medial knee joint load. Therefore, interventions that can reduce excessive medial knee loading may be beneficial in reducing the risk of structural progression. Traditional quadriceps strengthening can improve pain and function in people with knee osteoarthritis but does not appear to reduce medial knee load. A neuromuscular exercise program, emphasising optimal alignment of the trunk and lower limb joints relative to one another, as well as quality of movement performance, while dynamically and functionally strengthening the lower limb muscles, may be able to reduce medial knee load. Such a program may also be superior to traditional quadriceps strengthening with respect to improved pain and physical function because of the functional and dynamic nature. This randomised controlled trial will investigate the effect of a neuromuscular exercise program on medial knee joint loading, pain and function in individuals with medial knee joint osteoarthritis. We hypothesise that the neuromuscular program will reduce medial knee load as well as pain and functional limitations to a greater extent than a traditional quadriceps strengthening program. 100 people with medial knee pain, radiographic medial compartment osteoarthritis and varus malalignment will be recruited and randomly allocated to one of two 12-week exercise programs: quadriceps strengthening or neuromuscular exercise. Each program will involve 14 supervised exercise sessions with a physiotherapist plus four unsupervised sessions per week at home. The primary outcomes are medial knee load during walking (the peak external knee adduction moment from 3D gait analysis), pain, and self-reported physical function measured at baseline and immediately following the program. Secondary outcomes include the external knee adduction moment angular impulse, electromyographic muscle activation patterns, knee and hip muscle strength, balance, functional ability, and quality-of-life. The findings will help determine whether neuromuscular exercise is superior to traditional quadriceps strengthening regarding effects on knee load, pain and physical function in people with medial knee osteoarthritis and varus malalignment. Australian New Zealand Clinical Trials Registry reference: ACTRN12610000660088.
2011-01-01
Background Osteoarthritis of the knee involving predominantly the medial tibiofemoral compartment is common in older people, giving rise to pain and loss of function. Many people experience progressive worsening of the disease over time, particularly those with varus malalignment and increased medial knee joint load. Therefore, interventions that can reduce excessive medial knee loading may be beneficial in reducing the risk of structural progression. Traditional quadriceps strengthening can improve pain and function in people with knee osteoarthritis but does not appear to reduce medial knee load. A neuromuscular exercise program, emphasising optimal alignment of the trunk and lower limb joints relative to one another, as well as quality of movement performance, while dynamically and functionally strengthening the lower limb muscles, may be able to reduce medial knee load. Such a program may also be superior to traditional quadriceps strengthening with respect to improved pain and physical function because of the functional and dynamic nature. This randomised controlled trial will investigate the effect of a neuromuscular exercise program on medial knee joint loading, pain and function in individuals with medial knee joint osteoarthritis. We hypothesise that the neuromuscular program will reduce medial knee load as well as pain and functional limitations to a greater extent than a traditional quadriceps strengthening program. Methods/Design 100 people with medial knee pain, radiographic medial compartment osteoarthritis and varus malalignment will be recruited and randomly allocated to one of two 12-week exercise programs: quadriceps strengthening or neuromuscular exercise. Each program will involve 14 supervised exercise sessions with a physiotherapist plus four unsupervised sessions per week at home. The primary outcomes are medial knee load during walking (the peak external knee adduction moment from 3D gait analysis), pain, and self-reported physical function measured at baseline and immediately following the program. Secondary outcomes include the external knee adduction moment angular impulse, electromyographic muscle activation patterns, knee and hip muscle strength, balance, functional ability, and quality-of-life. Discussion The findings will help determine whether neuromuscular exercise is superior to traditional quadriceps strengthening regarding effects on knee load, pain and physical function in people with medial knee osteoarthritis and varus malalignment. Trial Registration Australian New Zealand Clinical Trials Registry reference: ACTRN12610000660088 PMID:22141334
Axelsen, M B; Stoltenberg, M; Poggenborg, R P; Kubassova, O; Boesen, M; Bliddal, H; Hørslev-Petersen, K; Hanson, L G; Østergaard, M
2012-03-01
To determine whether dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) evaluated using semi-automatic image processing software can accurately assess synovial inflammation in rheumatoid arthritis (RA) knee joints. In 17 RA patients undergoing knee surgery, the average grade of histological synovial inflammation was determined from four biopsies obtained during surgery. A preoperative series of T(1)-weighted dynamic fast low-angle shot (FLASH) MR images was obtained. Parameters characterizing contrast uptake dynamics, including the initial rate of enhancement (IRE), were generated by the software in three different areas: (I) the entire slice (Whole slice); (II) a manually outlined region of interest (ROI) drawn quickly around the joint, omitting large artefacts such as blood vessels (Quick ROI); and (III) a manually outlined ROI following the synovial capsule of the knee joint (Precise ROI). Intra- and inter-reader agreement was assessed using the intra-class correlation coefficient (ICC). The IRE from the Quick ROI and the Precise ROI revealed high correlations to the grade of histological inflammation (Spearman's correlation coefficient (rho) = 0.70, p = 0.001 and rho = 0.74, p = 0.001, respectively). Intra- and inter-reader ICCs were very high (0.93-1.00). No Whole slice parameters were correlated to histology. DCE-MRI provides fast and accurate assessment of synovial inflammation in RA patients. Manual outlining of the joint to omit large artefacts is necessary.
Nishino, K; Hayashi, T; Suzuki, Y; Koga, Y; Omori, G
1999-01-01
The function and integrity of the knee joint following total knee arthroplasty (TKA) is determined at first by the design and implantation of the prosthesis, and later by the tension of soft tissues surrounding it. Accurate post-TKA motion data obtained intraoperatively could be used not only to optimize implantation techniques from a kinematic standpoint, but also to improve prosthetic design. We therefore developed a system specifically geared to photostereometric measurement of 6 d.o.f. knee motion. A total of eight LEDs are mounted on the prosthetic components in two sets of four by means of connecting measuring-bows. The positions of the LEDs are detected in three-dimensions by two sets of three linear CCD cameras, located bilaterally relative to the knee. The position and orientation of the femoral component relative to the tibial one are estimated from the positions of all LEDs in the sense of least-squares. Based upon results of various accuracy validation experiments performed after precise camera calibration, static overall accuracy and spatial resolution were considered to lie within 0.52 and 0.11 mm, respectively, at any point on the femoral articular surface.
Wang, Hao; Shen, Bin; Zeng, Yi
2014-12-01
There has been much debate and controversy about the optimal regimen of tranexamic acid in primary total knee arthroplasty. The purpose of this study was to undertake a meta-analysis to compare the efficacy of topical and intravenous regimen of tranexamic acid in primary total knee arthroplasty. A systematic review of the electronic databases PubMed, CENTRAL, Web of Science, and Embase was undertaken. All randomized controlled trials and prospective cohort studies evaluating the effectiveness of topical and intravenous tranexamic acid during primary total knee arthroplasty were included. The focus of the analysis was on the outcomes of blood loss, transfusion rate, and thromboembolic complications. Subgroup analysis was performed when possible. Of 328 papers identified, six trials were eligible for data extraction and meta-analysis comprising 679 patients (739 knees). We found no statistically significant difference between topical and intravenous administration of tranexamic acid in terms of blood loss, transfusion requirements and thromboembolic complications. Topical tranexamic acid has a similar efficacy to intravenous tranexamic acid in reducing both blood loss and transfusion rate without sacrificing safety in primary total knee arthroplasty. II. Copyright © 2014 Elsevier B.V. All rights reserved.
Kinematic alignment technique for total hip and knee arthroplasty
Rivière, Charles; Lazic, Stefan; Villet, Loïc; Wiart, Yann; Allwood, Sarah Muirhead; Cobb, Justin
2018-01-01
Conventional techniques for hip and knee arthroplasty have led to good long-term clinical outcomes, but complications remain despite better surgical precision and improvements in implant design and quality. Technological improvements and a better understanding of joint kinematics have facilitated the progression to ‘personalized’ implant positioning (kinematic alignment) for total hip (THA) and knee (TKA) arthroplasty, the true value of which remains to be determined. By achieving a true knee resurfacing, the kinematic alignment (KA) technique for TKA aims at aligning the components with the physiological kinematic axes of the knee and restoring the constitutional tibio-femoral joint line frontal and axial orientation and soft-tissue laxity. The KA technique for THA aims at restoring the native ‘combined femoro-acetabular anteversion’ and the hip’s centre of rotation, and occasionally adjusting the cup position and design based on the assessment of the individual spine-hip relation. The key element for optimal prosthetic joint kinematics (hip or knee) is to reproduce the femoral anatomy. The transverse acetabular ligament (TAL) is the reference landmark to adjust the cup position. Cite this article: EFORT Open Rev 2018;3:98-105. DOI: 10.1302/2058-5241.3.170022 PMID:29657851
Gait Kinematics in Individuals with Acute and Chronic Patellofemoral Pain.
Fox, Aaron; Ferber, Reed; Saunders, Natalie; Osis, Sean; Bonacci, Jason
2018-03-01
This study aimed to identify the discriminating kinematic gait characteristics between individuals with acute and chronic patellofemoral pain (PFP) and healthy controls. Ninety-eight runners with PFP (39 male, 59 female) and 98 healthy control runners (38 male, 60 female) ran on a treadmill at a self-selected speed while three-dimensional lower limb kinematic data were collected. Runners with PFP were split into acute (n = 25) and chronic (n = 73) subgroups on the basis of whether they had been experiencing pain for less or greater than 3 months, respectively. Principal component analysis and linear discriminant analysis were used to determine the combination of kinematic gait characteristics that optimally separated individuals with acute PFP and chronic PFP and healthy controls. Compared with controls, both the acute and chronic PFP subgroups exhibited greater knee flexion across stance and greater ankle dorsiflexion during early stance. The acute PFP subgroup demonstrated greater transverse plane hip motion across stance compared with healthy controls. In contrast, the chronic PFP subgroup demonstrated greater frontal plane hip motion, greater knee abduction, and reduced ankle eversion/greater ankle inversion across stance when compared with healthy controls. This study identified characteristics that discriminated between individuals with acute and chronic PFP when compared with healthy controls. Certain discriminating characteristics were shared between both the acute and chronic subgroups when compared with healthy controls, whereas others were specific to the duration of PFP.
Multi-Criteria Optimization of Regulation in Metabolic Networks
Higuera, Clara; Villaverde, Alejandro F.; Banga, Julio R.; Ross, John; Morán, Federico
2012-01-01
Determining the regulation of metabolic networks at genome scale is a hard task. It has been hypothesized that biochemical pathways and metabolic networks might have undergone an evolutionary process of optimization with respect to several criteria over time. In this contribution, a multi-criteria approach has been used to optimize parameters for the allosteric regulation of enzymes in a model of a metabolic substrate-cycle. This has been carried out by calculating the Pareto set of optimal solutions according to two objectives: the proper direction of flux in a metabolic cycle and the energetic cost of applying the set of parameters. Different Pareto fronts have been calculated for eight different “environments” (specific time courses of end product concentrations). For each resulting front the so-called knee point is identified, which can be considered a preferred trade-off solution. Interestingly, the optimal control parameters corresponding to each of these points also lead to optimal behaviour in all the other environments. By calculating the average of the different parameter sets for the knee solutions more frequently found, a final and optimal consensus set of parameters can be obtained, which is an indication on the existence of a universal regulation mechanism for this system.The implications from such a universal regulatory switch are discussed in the framework of large metabolic networks. PMID:22848435
NASA Astrophysics Data System (ADS)
Wang, Ping; Wu, Guangqiang
2013-03-01
Typical multidisciplinary design optimization(MDO) has gradually been proposed to balance performances of lightweight, noise, vibration and harshness(NVH) and safety for instrument panel(IP) structure in the automotive development. Nevertheless, plastic constitutive relation of Polypropylene(PP) under different strain rates, has not been taken into consideration in current reliability-based and collaborative IP MDO design. In this paper, based on tensile test under different strain rates, the constitutive relation of Polypropylene material is studied. Impact simulation tests for head and knee bolster are carried out to meet the regulation of FMVSS 201 and FMVSS 208, respectively. NVH analysis is performed to obtain mainly the natural frequencies and corresponding mode shapes, while the crashworthiness analysis is employed to examine the crash behavior of IP structure. With the consideration of lightweight, NVH, head and knee bolster impact performance, design of experiment(DOE), response surface model(RSM), and collaborative optimization(CO) are applied to realize the determined and reliability-based optimizations, respectively. Furthermore, based on multi-objective genetic algorithm(MOGA), the optimal Pareto sets are completed to solve the multi-objective optimization(MOO) problem. The proposed research ensures the smoothness of Pareto set, enhances the ability of engineers to make a comprehensive decision about multi-objectives and choose the optimal design, and improves the quality and efficiency of MDO.
Yoo, Joanne Y; Cai, Jenny; Chen, Antonia F; Austin, Matthew S; Sharkey, Peter F
2016-05-01
Some manufacturers have introduced polyethylene (PE) inserts in 1-mm increment thickness options to allow for finer adjustments in total knee arthroplasty kinematics. Two surgeons with extensive experience performed 88 total knee arthroplasties using implants with 1-mm PE inserts. After trial components were inserted and the optimal PE thickness was selected, the insert was removed and a trial insert size was randomly chosen from opaque envelopes (1-mm smaller, same size, and 1-mm larger). The knee was re-examined and the surgeon determined which size PE had been placed. Surgeons reliably determined insert thicknesses in 62.5% (55 of 88; P = .050) of trials. Surgeons were not able to accurately detect 1-mm incremental changes of trial PE implants on a consistent basis. The potential clinical usefulness of this concept should be further evaluated. Copyright © 2016 Elsevier Inc. All rights reserved.
Prophylactic knee bracing alters lower-limb muscle forces during a double-leg drop landing.
Ewing, Katie A; Fernandez, Justin W; Begg, Rezaul K; Galea, Mary P; Lee, Peter V S
2016-10-03
Anterior cruciate ligament (ACL) injury can be a painful, debilitating and costly consequence of participating in sporting activities. Prophylactic knee bracing aims to reduce the number and severity of ACL injury, which commonly occurs during landing maneuvers and is more prevalent in female athletes, but a consensus on the effectiveness of prophylactic knee braces has not been established. The lower-limb muscles are believed to play an important role in stabilizing the knee joint. The purpose of this study was to investigate the changes in lower-limb muscle function with prophylactic knee bracing in male and female athletes during landing. Fifteen recreational athletes performed double-leg drop landing tasks from 0.30m and 0.60m with and without a prophylactic knee brace. Motion analysis data were used to create subject-specific musculoskeletal models in OpenSim. Static optimization was performed to calculate the lower-limb muscle forces. A linear mixed model determined that the hamstrings and vasti muscles produced significantly greater flexion and extension torques, respectively, and greater peak muscle forces with bracing. No differences in the timings of peak muscle forces were observed. These findings suggest that prophylactic knee bracing may help to provide stability to the knee joint by increasing the active stiffness of the hamstrings and vasti muscles later in the landing phase rather than by altering the timing of muscle forces. Further studies are necessary to quantify whether prophylactic knee bracing can reduce the load placed on the ACL during intense dynamic movements. Copyright © 2016 Elsevier Ltd. All rights reserved.
The Popularity of Outcome Measures for Hip and Knee Arthroplasties.
Lovelock, Thomas M; Broughton, Nigel S; Williams, Cylie M
2018-01-01
The optimal methods of determining outcomes following hip and knee arthroplasty remain controversial. The objectives of this study were to determine the most frequently used outcome measures in randomized controlled trials (RCT) and study protocols registered with clinical trials registries (CTR) on hip and knee arthroplasty. A systematic search strategy was undertaken to identify the outcome measures used in RCT and CTR following joint arthroplasty. Databases searched included Embase, Ovid MEDLINE (including In-Process), Cochrane Central Register of Controlled Trials, CINAHL Plus, clinicaltrials.gov, ISRCTN registry, and ANZCTR. Differences in the use of outcome measures between RCT and CTR were assessed using logistic regression. There were 291 RCT and 113 CTR on hip arthroplasty and 452 RCT and 184 CTR on knee arthroplasty that met the inclusion criteria. The most popular outcome measures were the Harris Hip Score and the Knee Society Score. Multiple outcome measures were used in greater than 50% of the included studies. The Oxford Hip Score, Oxford Knee Score, EuroQol-5D, and Knee Injury and Osteoarthritis Outcome Score (all P < .001) were used in significantly more CTR than RCT. There is a clear preference for the use of the Harris Hip Score and Knee Society Score, contrary to existing international guidelines and reviews on the topic. Both measures require clinician input, which potentially influences their validity and increases their overall administration cost. Some patient-reported outcome measures, such as the Oxford Hip and Knee Scores, EuroQol-5D, and KOOS, appear to be increasing in popularity. Copyright © 2017 Elsevier Inc. All rights reserved.
Holsgaard-Larsen, A; Clausen, B; Søndergaard, J; Christensen, R; Andriacchi, T P; Roos, E M
2017-04-01
To investigate the effect of a neuro-muscular exercise (NEMEX) therapy program compared with instructions in optimized analgesics and anti-inflammatory drug use (PHARMA), on measures of knee-joint load in people with mild to moderate knee osteoarthritis (OA). We hypothesized that knee joint loading during walking would be reduced by NEMEX and potentially increased by PHARMA. Single-blind, randomized controlled trial (RCT) comparing NEMEX therapy twice a week with PHARMA. Participants with mild-to-moderate medial tibiofemoral knee OA were randomly allocated (1:1) to one of two 8-week treatments. Primary outcome was change in knee load during walking (Knee Index, a composite score from all three planes based on 3D movement analysis) after 8 weeks of intervention. Secondary outcomes were frontal plane peak knee adduction moment (KAM), Knee Injury and Osteoarthritis Outcome Scores (KOOS) and functional performance tests. Ninety three participants (57% women, 58 ± 8 years with a body mass index [BMI] of 27 ± 4 kg/m 2 (mean ± standard deviation [SD])) were randomized to NEMEX group (n = 47) or PHARMA (n = 46); data from 44 (94%) and 41 (89%) participants respectively, were available at follow-up. 49% of the participants in NEMEX and only 7% in PHARMA demonstrated good compliance. We found no difference in the primary outcome as evaluated by the Knee Index -0.07 [-0.17; 0.04] Nm/%BW HT. Secondary outcomes largely supported this finding. We found no difference in the primary outcome; knee joint load change during walking from a NEMEX program vs information on the recommended use of analgesics and anti-inflammatory drugs. ClinicalTrials.gov Identifier: NCT01638962 (July 3, 2012). Ethical Committee: S-20110153. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Hart, Harvi F; Culvenor, Adam G; Collins, Natalie J; Ackland, David C; Cowan, Sallie M; Machotka, Zuzana; Crossley, Kay M
2016-05-01
Abnormal gait after anterior cruciate ligament reconstruction (ACLR) may contribute to development and/or progression of knee osteoarthritis. To conduct a systematic review and meta-analysis of knee kinematics and joint moments during walking after ACLR. We searched seven electronic databases and reference lists of relevant papers, for cross-sectional, human-based observational studies comparing knee joint kinematics and moments during level walking in individuals with ACLR, with the uninjured contralateral knee or healthy individuals as a control. Two independent reviewers appraised methodological quality (modified Downs and Black scale). Where possible, data were pooled by time post-ACLR (RevMan), otherwise narrative synthesis was undertaken. Thirty-four studies were included. Meta-analysis revealed significant sagittal plane deficits in ACLR knees. We found greater knee flexion angles (standardised mean difference: 1.06; 95% CI 0.39 to 1.74) and joint moments (1.61; 0.87 to 2.35) <6 months post-ACLR, compared to healthy controls. However, lower peak knee flexion angles were identified 1-3 years (-2.21; -3.16 to -1.26) and ≥3 years post-ACLR (-1.38, -2.14 to -0.62), and lower knee flexion moment 6-12 months post-ACLR (-0.76; -1.40 to -0.12). Pooled data provided strong evidence of no difference in peak knee adduction moment >3 years after ACLR (vs healthy controls) (0.09; -0.63 to 0.81). No transverse plane conclusions could be drawn. Sagittal plane biomechanics, rather than the knee adduction moment, appear to be more relevant post-ACLR. Better understanding of sagittal plane biomechanics is necessary for optimal post-operative recovery, and to potentially prevent early onset and progression of knee OA after ACLR. PROSPERO systematic review protocol registration number CRD4201400882 2. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Yoshida, Shinya; Matsuzaki, Taro; Kamijo, Akio; Araki, Yoshitaka; Sakamoto, Makoto; Moriyama, Shigenori; Hoso, Masahiro
2013-01-01
[Purpose] This study was performed to investigate the histological changes that occur in the periphery of the sciatic nerve in rats undergoing knee immobilization. [Subjects and Methods] 29 male 9-week-old Wistar rats were divided randomly into a control group (C group, n = 7) and an immobilized group (I group, n = 22). The animals in the I group had the left knee joint immobilized in maximal flexion with plaster casts for two weeks. After the experimental period, we obtained cross-sections of tissues from the center of the left thigh, and the periphery of the sciatic nerve was observed under an optical microscope after hematoxylin-eosin staining. [Results] In contrast to the rats of C group, the rats in I group showed adherence between the bundle of nerve fibers and perineurium, as well as thickening of the perineurium. These histological changes were statistically significant. [Conclusions] Immobilization of the knee joints of rats resulted in characteristic histological changes in the connective tissue around the sciatic nerve. PMID:24259816
Keshmiri, Armin; Springorum, Hans; Baier, Clemens; Zeman, Florian; Grifka, Joachim; Maderbacher, Günther
2015-03-01
Several authors emphasise that the appearance of patellar maltracking after total knee arthroplasty (TKA) is caused by rotational malalignment of the femoral and tibial components. Ligament-balanced femoral component rotation was not found to be associated with abnormal postoperative patellar position. We hypothesised that a ligament-balanced technique in TKA has the ability to best re-establish patellar kinematics. In ten cadaveric knees TKA was performed assessing femoral rotation in ligament-balanced and different femoral and tibial component rotation alignments. Patellar kinematics after different component rotations were analysed using a commercial computer navigation system. Ligament-balanced femoral rotation showed the best re-establishment of patellar kinematics after TKA compared to the healthy pre-operative knee. In contrast to tibial component rotation, femoral component rotation had a major impact on patellofemoral kinematics. This investigation suggests that a ligament-balanced technique in TKA is most likely to re-establish natural patellofemoral kinematics. Tibial component rotation did not influence patellar kinematics.
Davis, Edward T; Pagkalos, Joseph; Gallie, Price A M; Macgroarty, Kelly; Waddell, James P; Schemitsch, Emil H
2015-01-01
Optimal component alignment in total knee arthroplasty has been associated with better functional outcome as well as improved implant longevity. The ability to align components optimally during minimally invasive (MIS) total knee replacement (TKR) has been a cause of concern. Computer navigation is a useful aid in achieving the desired alignment although it is limited by the error during the manual registration of landmarks. Our study aims to compare the registration process error between a standard and a MIS surgical approach. We hypothesized that performing the registration error via an MIS approach would increase the registration process error. Five fresh frozen lower limbs were routinely prepared and draped. The registration process was performed through an MIS approach. This was then extended to the standard approach and the registration was performed again. Two surgeons performed the registration process five times with each approach. Performing the registration process through the MIS approach was not associated with higher error compared to the standard approach in the alignment parameters of interest. This rejects our hypothesis. Image-free navigated MIS TKR does not appear to carry higher risk of component malalignment due to the registration process error. Navigation can be used during MIS TKR to improve alignment without reduced accuracy due to the approach.
Intra-operatively measured spastic semimembranosus forces of children with cerebral palsy.
Yucesoy, Can A; Temelli, Yener; Ateş, Filiz
2017-10-01
The knee kept forcibly in a flexed position is typical in cerebral palsy. Using a benchmark, we investigate intra-operatively if peak spastic hamstring force is measured in flexed knee positions. This tests the assumed shift of optimal length due to adaptation of spastic muscle and a decreasing force trend towards extension. Previously we measured spastic gracilis (GRA) and semitendinosus (ST) forces. Presently, we studied spastic semimembranosus (SM) and tested the following hypotheses: spastic SM forces are (1) high in flexed and (2) low in extended positions. We compared the data to those of GRA and ST to test (3) if percentages of peak force produced in flexed positions are different. During muscle lengthening surgery of 8 CP patients (9years, 4months; GMFCS levels=II-IV; limbs tested=13) isometric SM forces were measured from flexion (120°) to full extension (0°). Spastic SM forces were low in flexed knee positions (only 4.2% (3.4%) and 10.7% (9.7%) of peak force at KA=120° and KA=90° respectively, indicating less force production compared to the GRA or ST) and high in extended knee positions (even 100% of peak force at KA=0°). This indicates an absence of strong evidence for a shift of optimal muscle length of SM towards flexion. Copyright © 2017 Elsevier Ltd. All rights reserved.
Is coxa valga a predictor for the severity of knee osteoarthritis? A cross-sectional study.
Coskun Benlidayi, Ilke; Guzel, Rengin; Basaran, Sibel; Aksungur, Erol H; Seydaoglu, Gulsah
2015-05-01
In the present study, we aimed to evaluate the affect of the variations in hip anatomy and pelvic geometry on the severity of knee OA. Idiopathic knee OA patients fulfilling the clinical criteria of American College of Rheumatology for OA were enrolled in the study. Several measurements regarding the hip and pelvis were performed on pelvic radiographs. Each knee was graded according to the Kellgren and Lawrence (KL) radiographic system (0-4) along with a categorization in accordance with the medial tibiofemoral joint space widths (JSW). The study group consisted of 111 subjects. The inner and outer pelvic diameters were getting wider as the JSW grade increased. Likewise, among the hip measurements, femoral head, neck and shaft diameters and hip axis lengths were linked with KL grade. There were significant differences in neck-shaft angle (NSA) between groups of JSW with a highest NSA in JSW grade 3. The optimal cut-off value for NSA in predicting the severity of knee OA was 134.4°. Furthermore, NSA beyond 134.4° was found to increase the risk of severe knee OA eightfold. Variations in pelvic geometry and hip anatomy are associated with the severity of knee OA. People with NSA of above 134.4° have eightfold increased risk of developing severe knee OA. Pelvic radiographies could be evaluated at younger ages-particularly in people with high genetic predispositions-to identify the individuals at high risk and in turn, to tailor the preventive measures to these subjects.
Rouis, M; Coudrat, L; Jaafar, H; Filliard, J-R; Vandewalle, H; Barthelemy, Y; Driss, T
2015-12-01
To explore the isokinetic concentric strength of the knee muscle groups, and the relationship between the isokinetic knee extensors strength and the vertical jump performance in young elite female basketball players. Eighteen elite female basketball players performed a countermovement jump, and an isokinetic knee test using a Biodex dynamometer. The maximal isokinetic peak torque of the knee extensor and flexor muscles was recorded at four angular velocities (90°/s, 180°/s, 240°/s and 300°/s) for the dominant and non-dominant legs. The conventional hamstring/quadriceps ratio (H/Q) was assessed at each angular velocity for both legs. There was no significant difference between dominant and non-dominant leg whatever the angular velocity (all P>0.05). However, the H/Q ratio enhanced as the velocity increased from 180°/s to 300°/s (P<0.05). Furthermore, low to high significant positive correlations were detected between the isokinetic measures of the knee extensors and the vertical jump height. The highest one was found for the knee extensors peak torque at a velocity of 240°/s (r=0.88, P<0.001). The results accounted for an optimal velocity at which a strong relationship could be obtained between isokinetic knee extensors strength and vertical jump height. Interestingly, the H/Q ratio of the young elite female basketball players in the present study was unusual as it was close to that generally observed in regular sportsmen.
NASA Astrophysics Data System (ADS)
Lee, Han Sang; Kim, Hyeun A.; Kim, Hyeonjin; Hong, Helen; Yoon, Young Cheol; Kim, Junmo
2016-03-01
In spite of its clinical importance in diagnosis of osteoarthritis, segmentation of cartilage in knee MRI remains a challenging task due to its shape variability and low contrast with surrounding soft tissues and synovial fluid. In this paper, we propose a multi-atlas segmentation of cartilage in knee MRI with sequential atlas registrations and locallyweighted voting (LWV). First, bone is segmented by sequential volume- and object-based registrations and LWV. Second, to overcome the shape variability of cartilage, cartilage is segmented by bone-mask-based registration and LWV. In experiments, the proposed method improved the bone segmentation by reducing misclassified bone region, and enhanced the cartilage segmentation by preventing cartilage leakage into surrounding similar intensity region, with the help of sequential registrations and LWV.
Burger, C; Kabir, K; Mueller, M; Rangger, C; Minor, T; Tolba, R H
2006-01-01
In an ovine meniscal repair model, the patellofemoral (PF) osteoarthritis due to a non-sutured tear or failed repair was investigated. A radial meniscus tear was either sutured with polydioxanone (PDS), with a slow degrading polylactide long-term suture(LTS) or left without treatment. Knee joint cartilage in the PF and medial compartment was evaluated compared to normal knees (healthy controls). Retropatellar osteoarthritis in the non-sutured and sutured animals was intense in contrast to the control knees after 6 months in all groups (p < 0.001), and after 12 months in the PDS group (p < 0.001), LTS group and non-sutured animals (p < 0.05). Non-sutured meniscus tears and failed repair lead fast to intense PF osteoarthritis corresponding with tibial damage of the injured compartment.
Isotropic three-dimensional T2 mapping of knee cartilage: Development and validation.
Colotti, Roberto; Omoumi, Patrick; Bonanno, Gabriele; Ledoux, Jean-Baptiste; van Heeswijk, Ruud B
2018-02-01
1) To implement a higher-resolution isotropic 3D T 2 mapping technique that uses sequential T 2 -prepared segmented gradient-recalled echo (Iso3DGRE) images for knee cartilage evaluation, and 2) to validate it both in vitro and in vivo in healthy volunteers and patients with knee osteoarthritis. The Iso3DGRE sequence with an isotropic 0.6 mm spatial resolution was developed on a clinical 3T MR scanner. Numerical simulations were performed to optimize the pulse sequence parameters. A phantom study was performed to validate the T 2 estimation accuracy. The repeatability of the sequence was assessed in healthy volunteers (n = 7). T 2 values were compared with those from a clinical standard 2D multislice multiecho (MSME) T 2 mapping sequence in knees of healthy volunteers (n = 13) and in patients with knee osteoarthritis (OA, n = 5). The numerical simulations resulted in 100 excitations per segment and an optimal radiofrequency (RF) excitation angle of 15°. The phantom study demonstrated a good correlation of the technique with the reference standard (slope 0.9 ± 0.05, intercept 0.2 ± 1.7 msec, R 2 ≥ 0.99). Repeated measurements of cartilage T 2 values in healthy volunteers showed a coefficient of variation of 5.6%. Both Iso3DGRE and MSME techniques found significantly higher cartilage T 2 values (P < 0.03) in OA patients. Iso3DGRE precision was equal to that of the MSME T 2 mapping in healthy volunteers, and significantly higher in OA (P = 0.01). This study successfully demonstrated that high-resolution isotropic 3D T 2 mapping for knee cartilage characterization is feasible, accurate, repeatable, and precise. The technique allows for multiplanar reformatting and thus T 2 quantification in any plane of interest. 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:362-371. © 2017 International Society for Magnetic Resonance in Medicine.
Local Drug Infiltration Analgesia During Knee Surgery to Reduce Postoperative Pain in Rats.
Buvanendran, Asokumar; Kroin, Jeffrey S; Della Valle, Craig J; Moric, Mario; Tuman, Kenneth J
2016-01-01
There is increasing interest in local infiltration analgesia (LIA) to reduce postoperative pain with knee surgery. Despite widespread use of LIA, wide variations in drug combinations, infiltration techniques, and the concomitant use of systemic analgesics have made it difficult to determine the optimal drug combination for LIA.Using a previously validated animal knee surgery model, we aimed to determine the optimal combination of medications to reduce postoperative pain, and the best anatomical location and timing for local drug injection during surgery. Knee surgery was performed in an adult rat model under isoflurane anesthesia. During surgery, combinations of bupivacaine, ketorolac, dexamethasone, and morphine were injected around the knee and compared to saline placebo. Similar medications were injected systemically as a comparator group. Postoperative pain was assessed by measuring spontaneous rearing activity. Injections were given after bone drilling and/or just before wound closure. The 3-drug LIA combination of bupivacaine, ketorolac, and dexamethasone increased rearing (decreased pain) at 2 hours (P = 0.0198) and 24 hours (P = 0.0384) postsurgery compared to saline. The same drugs injected systemically had no effect. The ketorolac/dexamethasone combination for LIA was also effective at 2 hours (P = 0.0006) and 24 hours (P = 0.0279), and ketorolac alone reduced pain at 2 hours (P = 0.0045). Bupivacaine alone was less effective, and the addition of morphine had no effect. The 3-drug combination infiltrated just after creating holes in bone was more effective than when given into the wound just before wound closure. Our animal study suggests that clinical trials with LIA combinations of local anesthetic, nonsteroidal anti-inflammatory drug, and corticosteroid might be useful for reducing postoperative pain after knee surgery, with the nonsteroidal anti-inflammatory drug having the greatest effect.Perioperative physicians should consider delivering LIA earlier during the procedure as opposed to solely at the time of wound closure.
Moulton, Samuel G; Geeslin, Andrew G; LaPrade, Robert F
2016-06-01
There are a variety of reported surgical techniques outcomes of chronic grade III posterolateral corner (PLC) knee injuries. It is unknown if outcomes differ among the various surgical treatments. To systematically review the literature and report subjective and objective outcomes for surgical treatment strategies for chronic grade III PLC injuries to determine the optimal surgical technique. Systematic review; Level of evidence, 4. A systematic review of the literature including Cochrane, PubMed, Medline, and Embase was performed. The following search terms were used: posterolateral corner knee, posterolateral knee, posterolateral instability, multiligament knee, and knee dislocation. Inclusion criteria were outcome studies of surgical treatment for chronic PLC knee injuries with a minimum 2-year follow-up, subjective outcomes, objective outcomes including varus stability, and subgroup data on PLC injuries. Two investigators independently reviewed all abstracts. Accepted definitions of varus stability on examination or stress radiographs, and the need for revision surgery, were used to categorically define success and failure. Fifteen studies with a total of 456 patients were included in this study. The 15 studies included 5 with level 3 evidence and 10 with level 4 evidence. The mean age of the patients in each study ranged from 25.2 to 40 years, the reported mean time to surgery ranged from 5.5 to 52.8 months, and the mean follow-up duration ranged from 2 to 16.3 years. Mean postoperative Lysholm scores ranged from 65.5 to 91.8; mean postoperative International Knee Documentation Committee (IKDC) scores ranged from 62.6 to 86.0. Based on objective stability, there was an overall success rate of 90% and a 10% failure rate of PLC reconstruction. A variety of surgical techniques were reported. Chronic PLC injuries were reconstructed in all studies, and while techniques varied, the surgical management of chronic PLC injuries had a 90% success rate and a 10% failure rate according to the individual investigators' examination or stress radiographic assessment of objective outcomes. More than half of the 456 patients had a combined posterior cruciate ligament-PLC injury. Surgical techniques included variations of fibular slings, capsular shifts, and anatomic-based techniques (fibular tunnel and tibial tunnel). Further research is needed to determine the optimal surgical technique for treating chronic grade III PLC injuries. © 2015 The Author(s).
2011-01-01
Background There is emerging evidence for a beneficial effect of meat consumption on the musculoskeletal system. However, whether it affects the risk of knee and hip osteoarthritis is unknown. We performed a prospective cohort study to examine the relationship between meat consumption and risk of primary hip and knee replacement for osteoarthritis. Methods Eligible 35,331 participants were selected from the Melbourne Collaborative Cohort Study recruited during 1990-1994. Consumption of fresh red meat, processed meat, chicken, and fish was assessed using a food frequency questionnaire. Primary hip and knee replacement for osteoarthritis during 2001-2005 was determined by linking the cohort records to the Australian National Joint Replacement Registry. Results There was a negative dose-response relationship between fresh red meat consumption and the risk of hip replacement (hazard ratio (HR) 0.94 per increase in intake of one time/week, 95% confidence interval (CI) 0.89-0.98). In contrast, there was no association with knee replacement risk (HR 0.98, 95% CI 0.94-1.02). Consumption of processed meat, chicken and fish were not associated with risk of hip or knee replacement. Conclusion A high level consumption of fresh red meat was associated with a decreased risk of hip, but not knee, joint replacement for osteoarthritis. One possible mechanism to explain these differential associations may be via an effect of meat intake on bone strength and hip shape. Further confirmatory studies are warranted. PMID:21235820
Wang, Yuanyuan; Simpson, Julie Anne; Wluka, Anita E; English, Dallas R; Giles, Graham G; Graves, Stephen; Cicuttini, Flavia M
2011-01-16
There is emerging evidence for a beneficial effect of meat consumption on the musculoskeletal system. However, whether it affects the risk of knee and hip osteoarthritis is unknown. We performed a prospective cohort study to examine the relationship between meat consumption and risk of primary hip and knee replacement for osteoarthritis. Eligible 35,331 participants were selected from the Melbourne Collaborative Cohort Study recruited during 1990-1994. Consumption of fresh red meat, processed meat, chicken, and fish was assessed using a food frequency questionnaire. Primary hip and knee replacement for osteoarthritis during 2001-2005 was determined by linking the cohort records to the Australian National Joint Replacement Registry. There was a negative dose-response relationship between fresh red meat consumption and the risk of hip replacement (hazard ratio (HR) 0.94 per increase in intake of one time/week, 95% confidence interval (CI) 0.89-0.98). In contrast, there was no association with knee replacement risk (HR 0.98, 95% CI 0.94-1.02). Consumption of processed meat, chicken and fish were not associated with risk of hip or knee replacement. A high level consumption of fresh red meat was associated with a decreased risk of hip, but not knee, joint replacement for osteoarthritis. One possible mechanism to explain these differential associations may be via an effect of meat intake on bone strength and hip shape. Further confirmatory studies are warranted.
Hussein, Mohamed
2017-07-01
Accurate delivery of an injection into the intra-articular space of the knee is achieved in only two thirds of knees when using the standard anterolateral portal. The use of a modified full-flexion anterolateral portal provides a highly accurate, less painful, and more effective method for reproducible intra-articular injection without the need for ultrasonographic or fluoroscopic guidance in patients with dry osteoarthritis of the knee. The accuracy of needle placement was assessed in a prospective series of 140 consecutive injections in patients with symptomatic degenerative knee arthritis without clinical knee effusion. Procedural pain was determined using the Numerical Rating Scale. The accuracy rates of needle placement were confirmed with fluoroscopic imaging to document the dispersion pattern of injected contrast material. Using the standard anterolateral portal, 52 of 70 injections were confirmed to have been placed in the intra-articular space on the first attempt (accuracy rate, 74.2%). Using the modified full-flexion anterolateral portal, 68 of 70 injections were placed in the intra-articular space on the first attempt (accuracy rate, 97.1%; P = 0.000). This study revealed that using the modified full-flexion anterolateral portal for injections into the knee joint resulted in more accurate and less painful injections than those performed by the same orthopaedic surgeon using the standard anterolateral portal. In addition, the technique offered therapeutic delivery into the joint without the need for fluoroscopic confirmation. Therapeutic Level II.
Quantifying in vivo laxity in the anterior cruciate ligament and individual knee joint structures.
Westover, L M; Sinaei, N; Küpper, J C; Ronsky, J L
2016-11-01
A custom knee loading apparatus (KLA), when used in conjunction with magnetic resonance imaging, enables in vivo measurement of the gross anterior laxity of the knee joint. A numerical model was applied to the KLA to understand the contribution of the individual joint structures and to estimate the stiffness of the anterior-cruciate ligament (ACL). The model was evaluated with a cadaveric study using an in situ knee loading apparatus and an ElectroForce test system. A constrained optimization solution technique was able to predict the restraining forces within the soft-tissue structures and joint contact. The numerical model presented here allowed in vivo prediction of the material stiffness parameters of the ACL in response to applied anterior loading. Promising results were obtained for in vivo load sharing within the structures. The numerical model overestimated the ACL forces by 27.61-92.71%. This study presents a novel approach to estimate ligament stiffness and provides the basis to develop a robust and accurate measure of in vivo knee joint laxity.
Physical examination and imaging of medial collateral ligament and posteromedial corner of the knee.
Craft, Jason A; Kurzweil, Peter R
2015-06-01
The medial collateral ligament (MCL) is the most commonly injured knee ligament. Most will heal well with nonoperative treatment. However, not all medial knee injuries are the same. A detailed physical examination can help determine the severity of the medial-sided injury. When combined with advanced imaging, the examination will delineate damage to associated medial knee structures, including the location of MCL damage, posteromedial capsule injuries, and combined cruciate injuries. Failure to recognize MCL injuries that may be prone to chronic laxity can lead to significant disability, joint damage, and failure of concomitant cruciate ligament reconstructions. Magnetic resonance imaging is the mainstay of diagnostic imaging, with coronal sequences allowing full assessment of the MCL complex. Tangential views aid in the diagnosis of concomitant injuries. Stress radiography can play a role in evaluating MCL healing and subtle chronic laxity. Ultrasonography is also gaining acceptance as a means to assess MCL injuries. Use of a detailed examination and advanced imaging will allow optimal treatment of medial knee injuries and improve clinical outcomes.
Fricka, Kevin B; Sritulanondha, Supatra; McAsey, Craig J
2015-09-01
The optimal mode of fixation in total knee arthroplasty (TKA) is a subject of debate. We enrolled 100 TKA patients randomized to cemented or cementless fixation. Knee Society Scores (KSS), Oxford scores and pain visual analog scales (VAS) were collected pre-operatively and post-operatively. Two-year follow-up was obtained for 93 patients. The mean VAS trended higher for the cementless group at 4 months (P=0.06). At 2 years, the KSS functional scores, Oxford scores, and self-reported questions for satisfaction, less pain and better function were similar but the cemented group had higher KSS clinical scores (96.4 vs. 92.3, P=0.03). More radiolucencies were seen in cementless knees (P<0.001). The cementless group had one revision for instability and one cemented knee was revised for infection. Cementless TKA showed equivalent survivorship (revision for any reason as the endpoint) compared to cemented TKA at this early follow-up. Close monitoring of radiolucencies is important with continued follow-up. Copyright © 2015 Elsevier Inc. All rights reserved.
Rao, Allison J.; Erickson, Brandon J.; Cvetanovich, Gregory L.; Yanke, Adam B.; Bach, Bernard R.; Cole, Brian J.
2015-01-01
Meniscal tears are the most common knee injury, and partial meniscectomies are the most common orthopaedic surgical procedure. The injured meniscus has an impaired ability to distribute load and resist tibial translation. Partial or complete loss of the meniscus promotes early development of chondromalacia and osteoarthritis. The primary goal of treatment for meniscus-deficient knees is to provide symptomatic relief, ideally to delay advanced joint space narrowing, and ultimately, joint replacement. Surgical treatments, including meniscal allograft transplantation (MAT), high tibial osteotomy (HTO), and distal femoral osteotomy (DFO), are options that attempt to decrease the loads on the articular cartilage of the meniscus-deficient compartment by replacing meniscal tissue or altering joint alignment. Clinical and biomechanical studies have reported promising outcomes for MAT, HTO, and DFO in the postmeniscectomized knee. These procedures can be performed alone or in conjunction with ligament reconstruction or chondral procedures (reparative, restorative, or reconstructive) to optimize stability and longevity of the knee. Complications can include fracture, nonunion, patella baja, compartment syndrome, infection, and deep venous thrombosis. MAT, HTO, and DFO are effective options for young patients suffering from pain and functional limitations secondary to meniscal deficiency. PMID:26779547
Estimation of Quasi-Stiffness of the Human Knee in the Stance Phase of Walking
Shamaei, Kamran; Sawicki, Gregory S.; Dollar, Aaron M.
2013-01-01
Biomechanical data characterizing the quasi-stiffness of lower-limb joints during human locomotion is limited. Understanding joint stiffness is critical for evaluating gait function and designing devices such as prostheses and orthoses intended to emulate biological properties of human legs. The knee joint moment-angle relationship is approximately linear in the flexion and extension stages of stance, exhibiting nearly constant stiffnesses, known as the quasi-stiffnesses of each stage. Using a generalized inverse dynamics analysis approach, we identify the key independent variables needed to predict knee quasi-stiffness during walking, including gait speed, knee excursion, and subject height and weight. Then, based on the identified key variables, we used experimental walking data for 136 conditions (speeds of 0.75–2.63 m/s) across 14 subjects to obtain best fit linear regressions for a set of general models, which were further simplified for the optimal gait speed. We found R2 > 86% for the most general models of knee quasi-stiffnesses for the flexion and extension stages of stance. With only subject height and weight, we could predict knee quasi-stiffness for preferred walking speed with average error of 9% with only one outlier. These results provide a useful framework and foundation for selecting subject-specific stiffness for prosthetic and exoskeletal devices designed to emulate biological knee function during walking. PMID:23533662
Seah, R B; Pang, H N; Lo, N N; Chong, H C; Chin, P L; Chia, S L; Yeo, S J
2012-10-01
The success of total knee replacement (TKR) depends on optimal soft-tissue balancing, among many other factors. The objective of this study is to correlate post-operative anteroposterior (AP) translation of a posterior cruciate ligament-retaining TKR with clinical outcome at two years. In total 100 patients were divided into three groups based on their AP translation as measured by the KT-1000 arthrometer. Group 1 patients had AP translation < 5 mm, Group 2 had AP translation from 5 mm to 10 mm, and Group 3 had AP translation > 10 mm. Outcome assessment included range of movement of the knee, the presence of flexion contractures, hyperextension, knee mechanical axes and functional outcome using the Knee Society score, Oxford knee score and the Short-Form 36 questionnaire. At two years, patients in Group 2 reported significantly better Oxford knee scores than the other groups (p = 0.045). A positive correlation between range of movement and AP translation was noted, with patients in group 3 having the greatest range of movement (mean flexion: 117.9° (106° to 130°)) (p < 0.001). However, significantly more patients in Group 3 developed hyperextension > 10° (p = 0.01). In this study, the best outcome for cruciate-ligament retaining TKR was achieved in patients with an AP translation of 5 mm to 10 mm.
Brown, T N; O'Donovan, M; Hasselquist, L; Corner, B; Schiffman, J M
2016-01-01
Fifteen military personnel performed 30-cm drop landings to quantify how body borne load (light, ∼6 kg, medium, ∼20 kg, and heavy, ∼40 kg) impacts lower limb kinematics and knee joint energy absorption during landing, and determine whether greater lower limb flexion increases energy absorption while landing with load. Participants decreased peak hip (P = 0.002), and knee flexion (P = 0.007) posture, but did not increase hip (P = 0.796), knee (P = 0.427) or ankle (P = 0.161) energy absorption, despite exhibiting greater peak hip (P = 0.003) and knee (P = 0.001) flexion, and ankle (P = 0.003) dorsiflexion angular impulse when landing with additional load. Yet, when landing with the light and medium loads, greater hip (R(2) = 0.500, P = 0.003 and R(2) = 0.314, P = 0.030) and knee (R(2) = 0.431, P = 0.008 and R(2) = 0.342, P = 0.022) flexion posture predicted larger knee joint energy absorption. Thus, military training that promotes hip and knee flexion, and subsequently greater energy absorption during landing, may potentially reduce risk of musculoskeletal injury and optimize soldier performance. Published by Elsevier Ltd.
Wang, Wei-Te; Huang, Ling-Tzu; Chou, Ya-Hui; Wei, Ta-Sen; Lin, Chung-Che
2014-01-01
Objective. To investigate the relationship among walking speed, exercise capacity, and leg strength in community dwelling stroke subjects and to evaluate which one was the leading determinant factor of them. Design. This is a descriptive, cross-sectional study. Thirty-five chronic stroke patients who were able to walk independently in their community were enrolled. Walking speed was evaluated by using the 12-meter walking test. A maximal exercise test was used to determine the stroke subjects' exercise capacity. Knee extensor strength, measured as isokinetic torque, was assessed by isokinetic dynamometer. Results. The main walking speed of our subjects was 0.52 m/s. Peak oxygen uptake (VO2 peak) was 1.21 ± 0.43 L/min. Knee extensor strength, no matter whether paretic or nonparetic side, was significantly correlated to 12-meter walking speed and exercise capacity. Linear regression also showed the strength of the affected knee extensor was the determinant of walking speed and that of the nonparetic knee extensor was the determinant of exercise capacity in community dwelling stroke subjects. Conclusions. Walking speed and peak oxygen uptake were markedly decreased after stroke. Knee extensor strength of nonparetic leg was the most important determinant of exercise capacity of the community-dwelling stroke subjects. Knee extensor strengthening should be emphasized to help stroke patient to achieve optimal community living. PMID:25197712
Wang, Wei-Te; Huang, Ling-Tzu; Chou, Ya-Hui; Wei, Ta-Sen; Lin, Chung-Che
2014-01-01
To investigate the relationship among walking speed, exercise capacity, and leg strength in community dwelling stroke subjects and to evaluate which one was the leading determinant factor of them. This is a descriptive, cross-sectional study. Thirty-five chronic stroke patients who were able to walk independently in their community were enrolled. Walking speed was evaluated by using the 12-meter walking test. A maximal exercise test was used to determine the stroke subjects' exercise capacity. Knee extensor strength, measured as isokinetic torque, was assessed by isokinetic dynamometer. The main walking speed of our subjects was 0.52 m/s. Peak oxygen uptake (VO₂ peak) was 1.21 ± 0.43 L/min. Knee extensor strength, no matter whether paretic or nonparetic side, was significantly correlated to 12-meter walking speed and exercise capacity. Linear regression also showed the strength of the affected knee extensor was the determinant of walking speed and that of the nonparetic knee extensor was the determinant of exercise capacity in community dwelling stroke subjects. Walking speed and peak oxygen uptake were markedly decreased after stroke. Knee extensor strength of nonparetic leg was the most important determinant of exercise capacity of the community-dwelling stroke subjects. Knee extensor strengthening should be emphasized to help stroke patient to achieve optimal community living.
Hip and knee effects after implantation of a drop foot stimulator.
Yao, Daiwei; Lahner, Matthias; Jakubowitz, Eike; Thomann, Anna; Ettinger, Sarah; Noll, Yvonne; Stukenborg-Colsman, Christina; Daniilidis, Kiriakos
2017-01-01
An active ankle dorsiflexion is essential for a proper gait pattern. If there is a failure of the foot lifting, considerable impairments occur. The therapeutic effect of an implantable peroneus nerve stimulator (iPNS) for the ankle dorsiflexion is already approved by recent studies. However, possible affection for knee and hip motion after implantation of an iPNS is not well described. The objective of this retrospective study was to examine with a patient cohort whether the use of iPNS induces a lower-extremity flexion withdrawal response in the form of an increased knee and hip flexion during swing phase. Eighteen subjects (12 m/6 w) treated with an iPNS (ActiGait®, Otto Bock, Duderstadt, Germany) were examined in knee and hip motion by gait analysis with motion capture system (Vicon Motion System Ltd®, Oxford, UK) and Plug-in-Gait model after a mean follow up from 12.5 months. The data were evaluated and compared in activated and deactivated iPNS. Only little changes could be documented, as a slight average improvement in peak knee flexion during stand phase from 1.0° to 2.5° and peak hip flexion in stance from 3.1° to 2.1° In contrast, peak knee flexion during swing appeared similar (25.3° to 25.7°) same as peak hip flexion during swing. In comparison with the healthy extremity, a more symmetric course of the knee flexion during stand phase could be shown. No statistical significant improvements or changes in hip and knee joint could be shown in this study. Only a more symmetric knee flexion during stand phase and a less hip flexion during stand phase might be hints for a positive affection of iPNS for knee and hip joint. It seems that the positive effect of iPNS is only based on the improvement in ankle dorsiflexion according to the recent literature.
Ishijima, Muneaki; Watari, Taiji; Naito, Kiyohito; Kaneko, Haruka; Futami, Ippei; Yoshimura-Ishida, Kaori; Tomonaga, Akihito; Yamaguchi, Hideyo; Yamamoto, Tetsuro; Nagaoka, Isao; Kurosawa, Hisashi; Poole, Robin A; Kaneko, Kazuo
2011-02-14
We tested the hypothesis that there exist relationships between the onset of early stage radiographically defined knee osteoarthritis (OA), pain and changes in biomarkers of joint metabolism. Using Kellgren-Lawrence (K/L) grading early radiographic knee OA (K/L 2) was detected in 16 of 46 patients. These grades (K/L 1 is no OA and K/L 2 is early OA) were divided into two groups according to the presence or absence of persistent knee pain. Sera (s) and urines (u) were analysed with biomarkers for cartilage collagen cleavage (sC2C and uCTX-II) and synthesis (sCPII), bone resorption (uNTx) and synovitis (hyaluronic acid: sHA). sCPII decreased and sC2C/sCPII, uCTX-II/sCPII and sHA increased with onset of OA (K/L 2 versus K/L 1) irrespective of joint pain. In contrast, sC2C and uCTX-II remained unchanged in early OA patients. Of the patients with K/L grades 1 and 2 sC2C, sCPII, sHA, uNTX and uCTX-II were all significantly increased in patients with knee pain independent of grade. Among the K/L grade 2 subjects, only uCTX-II and uCTX-II/sCPII were increased in those with knee pain. In grade 1 patients both sC2C and sCPII were increased in those with knee pain. No such grade specific changes were seen for the other biomarkers including sHA. These results suggest that changes in cartilage matrix turnover detected by molecular biomarkers may reflect early changes in cartilage structure that account directly or indirectly for knee pain. Also K/L grade 1 patients with knee pain exhibit biomarker features of early OA.
Sheveleva, N; Minbayeva, L; Belyayeva, Y
2017-03-01
Reducing of articular cartilage functional volume in knee joint osteoarthritis occurs unevenly and accompanied with pathological changes of lower limb axis as a result of connective tissue and muscle structures dysfunction. Evaluation of X-ray knee joint space asymmetry seems to be informative to analyze the dynamics of lower extremities biomechanical imbalances characteristic for knee joint osteoarthritis. However, standardized method of X-ray joint space determining does not include its symmetry calculation. The purpose of the study was optimization of knee joint radiological examination by developing of X-ray knee joint space asymmetry index calculation method. The proposed method was used for comparative analysis of extracorporeal shock-wave therapy efficacy in 30 patients with knee joint osteoarthritis of 2-3 degrees (Kellgren-Lawrence, 1957). As a result of the conducted treatment statistically significant decrease of the X-ray knee joint space asymmetry index was observed (Me(Q1;Q3): Z=5.20, p<0.001) and amounted as 0.22 (0.18;0.24) before treatment and 0.12 (0.10;0.14) after. Also, statistically significant (Z=5.10; p=0.00001) changes of load asymmetry on front and rear foot sections were observed by the results of podometric survey in comparative assessment before (Me(Q1;Q3)=24(12;30)) and after (Me(Q1;Q3)=6(4;30)) course therapy. 30% (n=9) of the patients evaluated the outcome of the treatment as "excellent" (1 point), 63% (n=19) - as "good" (2 points) and only 7% (n=2) - as "acceptable" (3 points) according to the Roles and Maudsley score. The listed above data was regarded as an X-ray positive dynamics comparable with clinical improvement. Thus, the X-ray knee joint space asymmetry index, calculated according to the proposed method, allows to evaluate dynamics of articular surfaces congruency changes and provide differentiated approach to the treatment of knee joint osteoarthritis.
Park, Kwan Kyu; Hosseini, Ali; Tsai, Tsung-Yuan; Kwon, Young-Min; Li, Guoan
2015-02-05
The mechanisms that affect knee flexion after total knee arthroplasty (TKA) are still debatable. This study investigated the elongation of the superficial medial (sMCL) and lateral collateral ligaments (LCL) before and after a posterior cruciate retaining (CR) TKA. We hypothesized that overstretching of the collateral ligaments in high flexion after TKA could reduce maximal flexion of the knee. Three-dimensional models of 11 osteoarthritic knees of 11 patients including the insertions of the collateral ligaments were created using MR images. Each ligament was divided into three equal portions: anterior, middle and posterior portions. The shortest 3D wrapping length of each ligament portion was determined before and after the TKA surgery along a weight-bearing, single leg flexion path. The relationship between the changes of ligament elongation and the changes of the maximal knee flexion after TKAs was quantitatively analyzed. The sMCL showed significant increases in length only at low flexion after TKA; the LCL showed decreases in length at full extension, but increases with further flexion after TKA. The amount of increases of the maximum flexion angle after TKA was negatively correlated with the increases of the elongations of the anterior portion (p=0.010, r=0.733) and middle portion (p=0.049, r=0.604) of the sMCL as well as the anterior portion (p=0.010, r=0.733) of the LCL at maximal flexion of the knee. The results indicated that the increases of the length of the collateral ligaments at maximal flexion after TKA were associated with the decreases of the maximal flexion of the knee. Our data suggest that collateral ligament management should also be evaluated at higher knee flexion angles in order to optimize maximal flexion of the knee after TKAs. Copyright © 2014 Elsevier Ltd. All rights reserved.
Riaz, O; Aqil, A; Sisodia, G; Chakrabarty, G
2017-12-01
To prospectively compare long-term clinical and radiological outcomes following a cruciate retaining fixed-bearing (FB) and a mobile-bearing (MB) primary total knee replacement (TKR). We prospectively reviewed 113 TKRs in 99 patients (14 bilateral) with a PFC sigma cruciate retaining rotating platform system, at an average follow-up of 11.1 years (range 10-12). Results were contrasted with those from 89 TKRs in 72 patients (17 bilateral) with a PFC sigma cruciate fixed-bearing prosthesis, at an average follow-up of 12.1 years (range 10-14.1). Outcomes collected included pre- and post-operative range of motion, Oxford Knee Scores, complications encountered, as well as radiographical assessments of polyethylene wear. In the MB group, mean Oxford Knee Scores improved from 16 pre-operatively to 42 at final follow-up. The mean range of motion was 115° (75-130). In the FB group, mean Oxford Knee Scores improved from 16.2 pre-operatively to 42.5 at final follow-up. The mean range of motion was 111.2 (80-135) degrees at final follow-up. We failed to elicit an objectively demonstrable clinical difference between the MB- and FB-implanted knees. Similarly, radiological benefits of the MB implants with regard to polyethylene wear were not evident at a minimum 10-year follow-up.
Meniscus repair: the role of accelerated rehabilitation in return to sport.
Kozlowski, Erick J; Barcia, Anthony M; Tokish, John M
2012-06-01
With increasing understanding of the detrimental effects of the meniscectomized knee on outcomes and long-term durability, there is an ever increasing emphasis on meniscal preservation through repair. Repair in the young athlete is particularly challenging given the goals of returning to high-level sports. A healed meniscus is only the beginning of successful return to activity, and the understanding of "protection with progression" must be emphasized to ensure optimal return to performance. The principles of progression from low to high loads, single to multiplane activity, slow to high speeds, and stable to unstable platforms are cornerstones to this process. Emphasis on the kinetic chain environment that the knee will function within cannot be overemphasized. Communication between the operating surgeon and rehabilitation specialist is critical to optimizing effective return to sports.
Nyland, J; Wera, J; Henzman, C; Miller, T; Jakob, R; Caborn, D N M
2015-02-01
To sustain natural systems, there must be an ongoing balance between environmental, social, and economic considerations. A key element of sustainability theory is to identify the most vulnerable surroundings. The most vulnerable knee tissue is the articular cartilage as it is the last line of osteoarthritis (OA) defense. This tissue has a poor capacity for healing. Based on sustainability theory and social ecology concepts we propose that several key factors contribute to knee function preservation. Factors include health history, genetic predisposition, personal behaviors, and socio-environmental factors in addition to local-regional-global physiological system function. Addressing only some of these factors or any one factor in isolation may lead to less than optimal treatment effectiveness. The purpose of this commentary is to introduce a medical, surgical and rehabilitation management approach for patients with knee OA that considers more than physical function improvement. This approach also considers social, emotional, and environmental factors to better ensure patient satisfaction, fulfilled expectations and successful outcomes. A clinical care pathway is presented for a 57-year-old patient with medial compartment knee OA who is contemplating early arthroplasty versus a knee function preservation treatment approach. Early arthroplasty refers to high revision likelihood based on a minimum 15 year prosthesis life-expectancy. Copyright © 2014 Elsevier Ltd. All rights reserved.
Vas, Lakshmi; Pai, Renuka; Khandagale, Nishigandha; Pattnaik, Manorama
2014-01-01
We report a new technique for pulsed radiofrequency (PRF) of the entire nerve supply of the knee as an option in treating osteoarthritis (OA) of knee. We targeted both sensory and motor nerves supplying all the structures around the knee: joint, muscles, and skin to address the entire nociception and stiffness leading to peripheral and central sensitization in osteoarthritis. Ten patients with pain, stiffness, and loss of function in both knees were treated with ultrasonography (USG) guided PRF of saphenous, tibial, and common peroneal nerves along with subsartorial, peripatellar, and popliteal plexuses. USG guided PRF of the femoral nerve was also done to address the innervation of the quadriceps muscle. Assessment of pain (Numerical Rating Scale [NRS], pain DETECT, knee function [Western Ontario and McMaster Universities Osteoarthritis Index- WOMAC]) were documented pre and post PRF at 3 and 6 months. Knee radiographs (Kellgren-Lawrence [K-L] grading) were done before PRF and one week later. All the patients showed a sustained improvement of NRS, pain DETECT, and WOMAC at 3 and 6 months. The significant improvement of patellar position and tibio-femoral joint space was concordant with the patient's reporting of improvement in stiffness and pain. The sustained pain relief and muscle relaxation enabled the patients to optimize physiotherapy thereby improving endurance training to include the daily activities of life. We conclude that OA knee pain is a product of neuromyopathy and that PRF of the sensory and motor nerves appeared to be a safe, effective, and minimally invasive technique. The reduction of pain and stiffness improved the knee function and probably reduced the peripheral and central sensitization.
Decreased knee adduction moment does not guarantee decreased medial contact force during gait.
Walter, Jonathan P; D'Lima, Darryl D; Colwell, Clifford W; Fregly, Benjamin J
2010-10-01
Excessive contact force is believed to contribute to the development of medial compartment knee osteoarthritis. The external knee adduction moment (KAM) has been identified as a surrogate measure for medial contact force during gait, with an abnormally large peak value being linked to increased pain and rate of disease progression. This study used in vivo gait data collected from a subject with a force-measuring knee implant to assess whether KAM decreases accurately predict corresponding decreases in medial contact force. Changes in both quantities generated via gait modification were analyzed statistically relative to the subject's normal gait. The two gait modifications were a "medial thrust" gait involving knee medialization during stance phase and a "walking pole" gait involving use of bilateral walking poles. Reductions in the first (largest) peak of the KAM (32-33%) did not correspond to reductions in the first peak of the medial contact force. In contrast, reductions in the second peak and angular impulse of the KAM (15-47%) corresponded to reductions in the second peak and impulse of the medial contact force (12-42%). Calculated reductions in both KAM peaks were highly sensitive to rotation of the shank reference frame about the superior-inferior axis of the shank. Both peaks of medial contact force were best predicted by a combination of peak values of the external KAM and peak absolute values of the external knee flexion moment (R(2) = 0.93). Future studies that evaluate the effectiveness of gait modifications for offloading the medial compartment of the knee should consider the combined effect of these two knee moments. Published by Wiley Periodicals, Inc. J Orthop Res 28:1348-1354, 2010.
Passive stiffness of monoarticular lower leg muscles is influenced by knee joint angle.
Ateş, Filiz; Andrade, Ricardo J; Freitas, Sandro R; Hug, François; Lacourpaille, Lilian; Gross, Raphael; Yucesoy, Can A; Nordez, Antoine
2018-03-01
While several studies demonstrated the occurrence of intermuscular mechanical interactions, the physiological significance of these interactions remains a matter of debate. The purpose of this study was to quantify the localized changes in the shear modulus of the gastrocnemius lateralis (GL), monoarticular dorsi- and plantar-flexor muscles induced by a change in knee angle. Participants underwent slow passive ankle rotations at the following two knee positions: knee flexed at 90° and knee fully extended. Ultrasound shear wave elastography was used to assess the muscle shear modulus of the GL, soleus [both proximally (SOL-proximal) and distally (SOL distal)], peroneus longus (PERL), and tibialis anterior (TA). This was performed during two experimental sessions (experiment I: n = 11; experiment II: n = 10). The shear modulus of each muscle was compared between the two knee positions. The shear modulus was significantly higher when the knee was fully extended than when the knee was flexed (P < 0.001) for the GL (averaged increase on the whole range of motion: + 5.8 ± 1.3 kPa), SOL distal (+ 4.5 ± 1.5 kPa), PERL (+ 1.1 ± 0.7 kPa), and TA (+ 1.6 ± 1.0 kPa). In contrast, a lower SOL-proximal shear modulus (P < 0.001, - 5.9 ± 1.0 kPa) was observed. As the muscle shear modulus is linearly related to passive muscle force, these results provide evidence of a non-negligible intermuscular mechanical interaction between the human lower leg muscles during passive ankle rotations. The role of these interactions in the production of coordinated movements requires further investigation.
Stanley, Jeremy C; Robinson, Kerian G; Devitt, Brian M; Richmond, Anneka K; Webster, Kate E; Whitehead, Timothy S; Feller, Julian A
2016-03-01
There are numerous methods available to assist surgeons in the accurate correction of varus alignment during medial opening wedge high tibial osteotomy (MOWHTO). Preoperative planning performed with radiographs or more recently intraoperative computer navigation software has been used. The aim of the study was to compare the accuracy of computer navigated versus non-navigated techniques to correct varus alignment of the knee. The preoperative and postoperative radiographs of 117 knees that underwent MOWHTO were investigated to assess radiographic limb alignment 12-months postoperatively. The desired correction was defined as a weight bearing line (Mikulicz point {MP}) 58% of the width of the tibial plateau from the medial tibial margin. Sixty-five knees were corrected using a conventional technique and 52 knees were corrected using computer navigation. The mean MP percentage was 59% in the navigated group, compared with 56% in the fluoroscopic group (p=0.183). 51.9% of the navigation knees were corrected to within five percent of the desired correction, in contrast to 38.5% of the fluoroscopically corrected knees (p=0.15). 71.2% of the navigated knees were corrected to within 10% of the desired correction, compared with 63.1% of the fluoroscopically corrected knees (p=0.36). Large preoperative deformities were more accurately corrected with navigation assistance (57% vs 49%, p=0.049). No statistically significant difference was found in the radiographic correction of varus alignment twelve months postoperatively between navigated and fluoroscopic techniques of MOWHTO. However, a subgroup analysis demonstrated that larger preoperative varus deformities may be more accurately corrected using computer navigation. Copyright © 2016 Elsevier B.V. All rights reserved.
Rosenberger, Ralf E; Hoser, Christian; Quirbach, Sebastian; Attal, Rene; Hennerbichler, Alfred; Fink, Christian
2008-03-01
Accuracy of implant positioning and reconstruction of the mechanical leg axis are major requirements for achieving good long-term results in total knee arthroplasty (TKA). The purpose of the present study was to determine whether image-free computer navigation technology has the potential to improve the accuracy of component alignment in TKA cohorts of experienced surgeons immediately and constantly. One hundred patients with primary arthritis of the knee underwent the unilateral total knee arthroplasty. The cohort of 50 TKAs implanted with conventional instrumentation was directly followed by the cohort of the very first 50 computer-assisted TKAs. All surgeries were performed by two senior surgeons. All patients received the Zimmer NexGen total knee prosthesis (Zimmer Inc., Warsaw, IN, USA). There was no variability regarding surgeons or surgical technique, except for the use of the navigation system (StealthStation) Treon plus Medtronic Inc., Minnesota, MI, USA). Accuracy of implant positioning was measured on postoperative long-leg standing radiographs and standard lateral X-rays with regard to the valgus angle and the coronal and sagittal component angles. In addition, preoperative deformities of the mechanical leg axis, tourniquet time, age, and gender were correlated. Statistical analyses were performed using the SPSS 15.0 (SPSS Inc., Chicago, IL, USA) software package. Independent t-tests were used, with significance set at P < 0.05 (two-tailed) to compare differences in mean angular values and frontal mechanical alignment between the two cohorts. To compute the rate of optimally implanted prostheses between the two groups we used the chi(2) test. The average postoperative radiological frontal mechanical alignment was 1.88 degrees of varus (range 6.1 degrees of valgus-10.1 degrees of varus; SD 3.68 degrees ) in the conventional cohort and 0.28 degrees of varus (range 3.7 degrees -6.0 degrees of varus; SD 1.97 degrees ) in the navigated cohort. Including all criteria for optimal implant alignment, 16 cases (32%) in the conventional cohort and 31 cases (62%) in the navigated cohort have been implanted optimally. The average difference in tourniquet time was modest with additional 12.9 min in the navigated cohort compared to the conventional cohort. Our findings suggest that the experienced knee surgeons can improve immediately and constantly the accuracy of component orientation using an image-free computer-assisted navigation system in TKA. The computer-assisted technology has shown to be easy to use, safe, and efficient in routine knee replacement surgery. We believe that navigation is a key technology for various current and future surgical alignment topics and minimal-invasive lower limb surgery.
Dual-joint modeling for estimation of total knee replacement contact forces during locomotion.
Hast, Michael W; Piazza, Stephen J
2013-02-01
Model-based estimation of in vivo contact forces arising between components of a total knee replacement is challenging because such forces depend upon accurate modeling of muscles, tendons, ligaments, contact, and multibody dynamics. Here we describe an approach to solving this problem with results that are tested by comparison to knee loads measured in vivo for a single subject and made available through the Grand Challenge Competition to Predict in vivo Tibiofemoral Loads. The approach makes use of a "dual-joint" paradigm in which the knee joint is alternately represented by (1) a ball-joint knee for inverse dynamic computation of required muscle controls and (2) a 12 degree-of-freedom (DOF) knee with elastic foundation contact at the tibiofemoral and patellofemoral articulations for forward dynamic integration. Measured external forces and kinematics were applied as a feedback controller and static optimization attempted to track measured knee flexion angles and electromyographic (EMG) activity. The resulting simulations showed excellent tracking of knee flexion (average RMS error of 2.53 deg) and EMG (muscle activations within ±10% envelopes of normalized measured EMG signals). Simulated tibiofemoral contact forces agreed qualitatively with measured contact forces, but their RMS errors were approximately 25% of the peak measured values. These results demonstrate the potential of a dual-joint modeling approach to predict joint contact forces from kinesiological data measured in the motion laboratory. It is anticipated that errors in the estimation of contact force will be reduced as more accurate subject-specific models of muscles and other soft tissues are developed.
Caruthers, Elena J; Oxendale, Kassandra K; Lewis, Jacqueline M; Chaudhari, Ajit M W; Schmitt, Laura C; Best, Thomas M; Siston, Robert A
2018-04-01
Stair descent (SD) is a common, difficult task for populations who are elderly or have orthopaedic pathologies. Joint torques of young, healthy populations during SD increase at the hip and ankle with increasing speed but not at the knee, contrasting torque patterns during gait. To better understand the sources of the knee torque pattern, we used dynamic simulations to estimate knee muscle forces and how they modulate center of mass (COM) acceleration across SD speeds (slow, self-selected, and fast) in young, healthy adults. The vastus lateralis and vastus medialis forces decreased from slow to self-selected speeds as the individual lowered to the next step. Since the vasti are primary contributors to vertical support during SD, they produced lower forces at faster speeds due to the lower need for vertical COM support observed at faster speeds. In contrast, the semimembranosus and rectus femoris forces increased across successive speeds, allowing the semimembranosus to increase acceleration downward and forward and the rectus femoris to provide more vertical support and resistance to forward progression as SD speed increased. These results demonstrate the utility of dynamic simulations to extend beyond traditional inverse dynamics analyses to gain further insight into muscle mechanisms during tasks like SD.
Nielsen, Flemming K; Egund, Niels; Jørgensen, Anette; Peters, David A; Jurik, Anne Grethe
2016-11-16
Bone marrow lesions (BMLs) in knee osteoarthritis (OA) can be assessed using fluid sensitive and contrast enhanced sequences. The association between BMLs and symptoms has been investigated in several studies but only using fluid sensitive sequences. Our aims were to assess BMLs by contrast enhanced MRI sequences in comparison with a fluid sensitive STIR sequence using two different segmentation methods and to analyze the association between the MR findings and disability and pain. Twenty-two patients (mean age 61 years, range 41-79 years) with medial femoro-tibial knee OA obtained MRI and filled out a WOMAC questionnaire at baseline and follow-up (median interval of 334 days). STIR, dynamic contrast enhanced-MRI (DCE-MRI) and fat saturated T1 post-contrast (T1 CE FS) MRI sequences were obtained. All STIR and T1 CE FS sequences were assessed independently by two readers for STIR-BMLs and contrast enhancing areas of BMLs (CEA-BMLs) using manual segmentation and computer assisted segmentation, and the measurements were compared. DCE-MRIs were assessed for the relative distribution of voxels with an inflammatory enhancement pattern, N voxel , in the bone marrow. All findings were compared to WOMAC scores, including pain and overall symptoms, and changes from baseline to follow-up were analyzed. The average volume of CEA-BML was smaller than the STIR-BML volume by manual segmentation. The opposite was found for computer assisted segmentation where the average CEA-BML volume was larger than the STIR-BML volume. The contradictory finding by computer assisted segmentation was partly caused by a number of outliers with an apparent generally increased signal intensity in the anterior parts of the femoral condyle and tibial plateau causing an overestimation of the CEA-BML volume. Both CEA-BML, STIR-BML and N voxel were significantly correlated with symptoms and to a similar degree. A significant reduction in total WOMAC score was seen at follow-up, but no significant changes were observed for either CEA-BML, STIR-BML or N voxel . Neither the degree nor the volume of contrast enhancement in BMLs seems to add any clinical information compared to BMLs visualized by fluid sensitive sequences. Manual segmentation may be needed to obtain valid CEA-BML measurements.
NASA Astrophysics Data System (ADS)
Butler, M. L.; Rainford, L.; Last, J.; Brennan, P. C.
2009-02-01
Introduction The American Association of Medical Physicists is currently standardizing the exposure index (EI) value. Recent studies have questioned whether the EI value offered by manufacturers is optimal. This current work establishes optimum EIs for the antero-posterior (AP) projections of a pelvis and knee on a Carestream Health (Kodak) CR system and compares these with manufacturers recommended EI values from a patient dose and image quality perspective. Methodology Human cadavers were used to produce images of clinically relevant standards. Several exposures were taken to achieve various EI values and corresponding entrance surface doses (ESD) were measured using thermoluminescent dosimeters. Image quality was assessed by 5 experienced clinicians using anatomical criteria judged against a reference image. Visualization of image specific common abnormalities was also analyzed to establish diagnostic efficacy. Results A rise in ESD for both examinations, consistent with increasing EI was shown. Anatomic image quality was deemed to be acceptable at an EI of 1560 for the AP pelvis and 1590 for the AP knee. From manufacturers recommended values, a significant reduction in ESD (p=0.02) of 38% and 33% for the pelvis and knee respectively was noted. Initial pathological analysis suggests that diagnostic efficacy at lower EI values may be projection-specific. Conclusion The data in this study emphasize the need for clinical centres to consider establishing their own EI guidelines, and not necessarily relying on manufacturers recommendations. Normal and abnormal images must be used in this process.
Borić, Igor; Rod, Eduard; Jeleč, Željko; Radić, Andrej; Vrdoljak, Trpimir; Skelin, Andrea; Trbojević-Akmačić, Irena; Plečko, Mihovil; Primorac, Dragan
2017-01-01
Osteoarthritis (OA) is one of the leading musculoskeletal disorders in the adult population. It is associated with cartilage damage triggered by the deterioration of the extracellular matrix tissue. The present study explores the effect of intra-articular injection of autologous microfragmented adipose tissue to host chondrocytes and cartilage proteoglycans in patients with knee OA. A prospective, non-randomized, interventional, single-center, open-label clinical trial was conducted from January 2016 to April 2017. A total of 17 patients were enrolled in the study, and 32 knees with osteoarthritis were assessed. Surgical intervention (lipoaspiration) followed by tissue processing and intra-articular injection of the final microfragmented adipose tissue product into the affected knee(s) was performed in all patients. Patients were assessed for visual analogue scale (VAS), delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC) and immunoglobulin G (IgG) glycans at the baseline, three, six and 12 months after the treatment. Magnetic resonance sequence in dGEMRIC due to infiltration of the anionic, negatively charged contrast gadopentetate dimeglumine (Gd-DTPA2−) into the cartilage indicated that the contents of cartilage glycosaminoglycans significantly increased in specific areas of the treated knee joint. In addition, dGEMRIC consequently reflected subsequent changes in the mechanical axis of the lower extremities. The results of our study indicate that the use of autologous and microfragmented adipose tissue in patients with knee OA (measured by dGEMRIC MRI) increased glycosaminoglycan (GAG) content in hyaline cartilage, which is in line with observed VAS and clinical results. PMID:29027984
Effect of polydeoxyribonucleotide injection on pes anserine bursitis: A case report.
Mun, Jong-Uk; Cho, Hyung R; Bae, Sae M; Park, Soo K; Choi, Soo L; Seo, Mi S; Lim, Young S; Rn, Soo H Woo; Kim, Young U
2017-10-01
Pes anserine (PA) bursitis is an inflammatory condition of the medial knee. The PA bursa becomes more painful when infected, damaged, or irritated. Although various treatment options have been attempted to treat PA bursitis, optimal treatments are still debated. This study aims to investigate the effect of polydeoxyribonucleotide (PDRN) injection on reducing pain and inflammation in a patient presenting with PA bursitis. A 50-year-old female patient was admitted to our pain clinic with symptoms of tenderness and pain over the medial knee. Physical examination revealed the pain to be located over the proximal medial tibia at the insertion of the conjoined tendons of the PA. The knee had lost its range of movement and strength, and resisted knee flexion. She was diagnosed as having PA bursitis. Ultrasound guided PA bursa injection was carried out. Follow-up for the patient was more than eight months. She showed good improvement in PA bursitis without any complications. This is the first successful report of successful PDRN injection for PA bursa.
Yang, Jae-Hyuk; Lim, Hong Chul; Bae, Ji Hoon; Fernandez, Harry; Bae, Tae Soo; Wang, Joon Ho
2011-10-01
Descriptive laboratory study. The femoral anatomic insertion site and the optimal isometric point of popliteus tendon for posterolateral reconstruction are not well known. Purpose of this study was to determine the relative relationship between the femoral anatomic insertion and isometric point of popliteus muscle-tendon complex with the lateral epicondyle of femur. Thirty unpaired cadaveric knees were dissected to determine the anatomic femoral insertion of the popliteus tendon. The distance and the angle from the lateral epicondyle of femur to the center of the anatomic insertion of the popliteus tendon were measured using digital caliper and goniometer. Eight unpaired fresh cadaveric knees were examined to determine the optimal isometric point of femoral insertion of popliteus tendon using computer-controlled motion capture analysis system (Motion Analysis, CA, USA). Distances from targeted tibial tunnel for popliteus tendon reconstruction to the 35 points gained on the lateral surface of femur were recorded at 0, 30, 60, 90, and 120° knee flexion. A point with the least excursion (<2.0 mm) was determined as the isometric point. The center of anatomic insertion points and the optimal isometric point for the main fibers of popliteus tendon were found to be posterior and distal to the lateral epicondyle of femur. The distance from the lateral epicondyle of femur to the center of anatomic femoral insertion of popliteus tendon was 11.3 ± 1.2 mm (mean ± SD). The angle between long axis of femur and the line from lateral epicondyle of femur to anatomic femoral insertion of popliteus tendon was 31.4 ± 5.3°. The isometric points for the femoral insertion of popliteus muscle-tendon complex were situated posterior and distal to the lateral epicondyle in all 8 knees. The distance between the least excursion point and the lateral epicondyle was calculated as 10.4 ± 1.7 mm. The angle between the long axis of femur and the line from lateral epicondyle of femur to optimum isometric point of popliteus tendon was calculated as 41.3 ± 14.9°. The optimal isometric point for the femoral insertion of popliteus muscle-tendon complex is situated posterior and distal to the lateral epicondyle of femur. Femoral tunnel for "posterolateral corner sling procedure" should be placed at this point to achieve least amount of graft excursion during knee motion.
Walter, Jonathan P; Pandy, Marcus G
2017-10-01
The aim of this study was to perform multi-body, muscle-driven, forward-dynamics simulations of human gait using a 6-degree-of-freedom (6-DOF) model of the knee in tandem with a surrogate model of articular contact and force control. A forward-dynamics simulation incorporating position, velocity and contact force-feedback control (FFC) was used to track full-body motion capture data recorded for multiple trials of level walking and stair descent performed by two individuals with instrumented knee implants. Tibiofemoral contact force errors for FFC were compared against those obtained from a standard computed muscle control algorithm (CMC) with a 6-DOF knee contact model (CMC6); CMC with a 1-DOF translating hinge-knee model (CMC1); and static optimization with a 1-DOF translating hinge-knee model (SO). Tibiofemoral joint loads predicted by FFC and CMC6 were comparable for level walking, however FFC produced more accurate results for stair descent. SO yielded reasonable predictions of joint contact loading for level walking but significant differences between model and experiment were observed for stair descent. CMC1 produced the least accurate predictions of tibiofemoral contact loads for both tasks. Our findings suggest that reliable estimates of knee-joint loading may be obtained by incorporating position, velocity and force-feedback control with a multi-DOF model of joint contact in a forward-dynamics simulation of gait. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Total knee replacement with natural rollback.
Wachowski, Martin Michael; Walde, Tim Alexander; Balcarek, Peter; Schüttrumpf, Jan Philipp; Frosch, Stephan; Stauffenberg, Caspar; Frosch, Karl-Heinz; Fiedler, Christoph; Fanghänel, Jochen; Kubein-Meesenburg, Dietmar; Nägerl, Hans
2012-03-20
A novel class of total knee replacement (AEQUOS G1) is introduced which features a unique design of the articular surfaces. Based on the anatomy of the human knee and differing from all other prostheses, the lateral tibial "plateau" is convexly curved and the lateral femoral condyle is posteriorly shifted in relation to the medial femoral condyle. Under compressive forces the configuration of the articular surfaces of human knees constrains the relative motion of femur and tibia in flexion/extension. This constrained motion is equivalent to that of a four-bar linkage, the virtual 4 pivots of which are given by the centres of curvature of the articulating surfaces. The dimensions of the four-bar linkage were optimized to the effect that constrained motion of the total knee replacement (TKR) follows the flexional motion of the human knee in close approximation, particularly during gait. In pilot studies lateral X-ray pictures have demonstrated that AEQUOS G1 can feature the natural rollback in vivo. Rollback relieves the load of the patello-femoral joint and minimizes retropatellar pressure. This mechanism should reduce the prevalence of anterior knee pain. The articulating surfaces roll predominantly in the stance phase. Consequently sliding friction is replaced by the lesser rolling friction under load. Producing rollback should minimize material wear due to friction and maximize the lifetime of the prosthesis. To definitely confirm these theses one has to wait for the long term results. Copyright © 2011 Elsevier GmbH. All rights reserved.
Changes in in vivo knee contact forces through gait modification.
Kinney, Allison L; Besier, Thor F; Silder, Amy; Delp, Scott L; D'Lima, Darryl D; Fregly, Benjamin J
2013-03-01
Knee osteoarthritis (OA) commonly occurs in the medial compartment of the knee and has been linked to overloading of the medial articular cartilage. Gait modification represents a non-invasive treatment strategy for reducing medial compartment knee force. The purpose of this study was to evaluate the effectiveness of a variety of gait modifications that were expected to alter medial contact force. A single subject implanted with a force-measuring knee replacement walked using nine modified gait patterns, four of which involved different hiking pole configurations. Medial and lateral contact force at 25, 50, and 75% of stance phase, and the average value over all of stance phase (0-100%), were determined for each gait pattern. Changes in medial and lateral contact force values relative to the subject's normal gait pattern were determined by a Kruskal-Wallis test. Apart from early stance (25% of stance), medial contact force was most effectively reduced by walking with long hiking poles and wide pole placement, which significantly reduced medial and lateral contact force during stance phase by up to 34% (at 75% of stance) and 26% (at 50% of stance), respectively. Although this study is based on data from a single subject, the results provide important insight into changes in medial and lateral contact forces through gait modification. The results of this study suggest that an optimal configuration of bilateral hiking poles may significantly reduce both medial and lateral compartment knee forces in individuals with medial knee osteoarthritis. Copyright © 2012 Orthopaedic Research Society.
Lower limb fractures associated with multiligament knee injury
Stagnaro, Joaquin; Yacuzzi, Carlos; Barla, Jorge; Zicaro, Juan Pablo; Costa-Paz, Matias
2017-01-01
Objectives: Knee ligament injuries related to lower limb fractures are common and frequently unnoticed. Management of acute polytrauma is usually focused in the bone lesion and a complete physical examination might be really difficult. The purpose of this study was to analyze a series of patients who suffered multiligament knee injuries associated to a lower limb fracture. Hypothesis: The use of magnetic resonance imaging (MRI) during the initial management can lead to an early diagnosis of ligament injuries. Methods: A retrospective search was conducted from our hospital´s electronic database. We evaluated the initial diagnosis and acute surgical treatment, and management and functional outcomes after the ligament lesion was diagnosed. Results: Seven patients who presented a knee multiligament injury associated with a lower limb fracture were evaluated. The average age was 29 years. Primary diagnoses were: four tibial plateau fractures; one open fracture-dislocation of the knee; one open leg fracture and ipsilateral hip dislocation; and one bifocal femur fracture. Only three patients had an MRI during the initial management of trauma. Six out of seven patients had to be operated on for the multiligament knee injury. The period between the resolution of the fracture and the ligamentous repair was from 3 to 24 months. Conclusion: Poor functional outcomes are reported in patients with multiligament knee injuries associated with high-energy lower limb fractures. We consider an MRI during the initial management can lead to better outcomes. A trauma surgeon working alongside an arthroscopic surgeon might optimize the results for these lesions.
Ishii, Yoshinori; Noguchi, Hideo; Sato, Junko; Sakurai, Tetsuya; Toyabe, Shin-Ichi
2017-11-01
It is still controversial whether anteroposterior (AP) translation magnitude after total knee arthroplasty (TKA) affects clinical outcomes, particularly range of motion (ROM). This study examined the following two questions: (1) are AP translations at the mid- and long-term follow-up different for knees within the same patient treated with posterior cruciate ligament-retaining (PCLR) versus posterior cruciate ligament-substituting (PCLS) mobile-bearing TKA prosthesis designs? (2) Is the ROM at the mid- and long-term follow-up for knees treated with PCLR and PCLS designs correlated with the AP translation? Thirty-seven patients undergoing sequential bilateral TKA for osteoarthritis were prospectively enrolled. Patients received a PCLR implant in one knee and a PCLS implant in the other and were followed-up for an average 9.8 ± 3.2 years. The AP translations at 30° and 75° of knee flexion and the ROM of both knees were assessed. The implant design (p < 0.001), but not flexion angle (n.s.), had a significant effect on AP translation. AP translation values were larger in PCLR knees than in PCLS knees at both flexion angles (p < 0.0001). The ROM at the final follow-up in the two implant designs was similar (both 115°, n.s.). There was a weak correlation between ROM and AP translation at 30° in the PCLR knees (r = 0.397, p = 0.015), but no correlation at 75° or in the PCLS knees. Differently constrained prosthesis designs resulted in significantly different AP translational values within the same patient. This indicates that achieving good clinical outcomes and ROM after TKA may not be strongly influenced by the specifics of each patient's anatomical characteristics, but instead by knee constrainment. Clinically, this means that surgeons should familiarize themselves with the AP translation of the implant being used, as this may be the most important factor for optimizing outcomes after mobile-bearing TKA. Level of evidence II, prospective, comparative study.
Nascimento, Lucas R; Teixeira-Salmela, Luci F; Souza, Ricardo B; Resende, Renan A
2018-01-01
Study Design Systematic review with meta-analysis. Background The addition of hip strengthening to knee strengthening for persons with patellofemoral pain has the potential to optimize treatment effects. There is a need to systematically review and pool the current evidence in this area. Objective To examine the efficacy of hip strengthening, associated or not with knee strengthening, to increase strength, reduce pain, and improve activity in individuals with patellofemoral pain. Methods A systematic review of randomized and/or controlled trials was performed. Participants in the reviewed studies were individuals with patellofemoral pain, and the experimental intervention was hip and knee strengthening. Outcome data related to muscle strength, pain, and activity were extracted from the eligible trials and combined in a meta-analysis. Results The review included 14 trials involving 673 participants. Random-effects meta-analyses revealed that hip and knee strengthening decreased pain (mean difference, -3.3; 95% confidence interval [CI]: -5.6, -1.1) and improved activity (standardized mean difference, 1.4; 95% CI: 0.03, 2.8) compared to no training/placebo. In addition, hip and knee strengthening was superior to knee strengthening alone for decreasing pain (mean difference, -1.5; 95% CI: -2.3, -0.8) and improving activity (standardized mean difference, 0.7; 95% CI: 0.2, 1.3). Results were maintained beyond the intervention period. Meta-analyses showed no significant changes in strength for any of the interventions. Conclusion Hip and knee strengthening is effective and superior to knee strengthening alone for decreasing pain and improving activity in persons with patellofemoral pain; however, these outcomes were achieved without a concurrent change in strength. Level of Evidence Therapy, level 1a-. J Orthop Sports Phys Ther 2018;48(1):19-31. Epub 15 Oct 2017. doi:10.2519/jospt.2018.7365.
Smartphone assessment of knee flexion compared to radiographic standards.
Dietz, Matthew J; Sprando, Daniel; Hanselman, Andrew E; Regier, Michael D; Frye, Benjamin M
2017-03-01
Measuring knee range of motion (ROM) is an important assessment for the outcomes of total knee arthroplasty. Recent technological advances have led to the development and use of accelerometer-based smartphone applications to measure knee ROM. The purpose of this study was to develop, standardize, and validate methods of utilizing smartphone accelerometer technology compared to radiographic standards, visual estimation, and goniometric evaluation. Participants used visual estimation, a long-arm goniometer, and a smartphone accelerometer to determine range of motion of a cadaveric lower extremity; these results were compared to radiographs taken at the same angles. The optimal smartphone position was determined to be on top of the leg at the distal femur and proximal tibia location. Between methods, it was found that the smartphone and goniometer were comparably reliable in measuring knee flexion (ICC=0.94; 95% CI: 0.91-0.96). Visual estimation was found to be the least reliable method of measurement. The results suggested that the smartphone accelerometer was non-inferior when compared to the other measurement techniques, demonstrated similar deviations from radiographic standards, and did not appear to be influenced by the person performing the measurements or the girth of the extremity. Copyright © 2016 Elsevier B.V. All rights reserved.
Smartphone Assessment of Knee Flexion Compared to Radiographic Standards
Dietz, Matthew J.; Sprando, Daniel; Hanselman, Andrew E.; Regier, Michael D.; Frye, Benjamin M.
2017-01-01
Purpose Measuring knee range of motion (ROM) is an important assessment for the outcomes of total knee arthroplasty. Recent technological advances have led to the development and use of accelerometer-based smartphone applications to measure knee ROM. The purpose of this study was to develop, standardize, and validate methods of utilizing smartphone accelerometer technology compared to radiographic standards, visual estimation, and goniometric evaluation. Methods Participants used visual estimation, a long-arm goniometer, and a smartphone accelerometer to determine range of motion of a cadaveric lower extremity; these results were compared to radiographs taken at the same angles. Results The optimal smartphone position was determined to be on top of the leg at the distal femur and proximal tibia location. Between methods, it was found that the smartphone and goniometer were comparably reliable in measuring knee flexion (ICC = 0.94; 95% CI: 0.91–0.96). Visual estimation was found to be the least reliable method of measurement. Conclusions The results suggested that the smartphone accelerometer was non-inferior when compared to the other measurement techniques, demonstrated similar deviations from radiographic standards, and did not appear to be influenced by the person performing the measurements or the girth of the extremity. PMID:28179062
Czaplicki, Adam; Jarocka, Marta; Walawski, Jacek
2015-01-01
The aim of this study was to evaluate the serial change of isokinetic muscle strength of the knees before and after anterior cruciate ligament reconstruction (ACLR) in physically active males and to estimate the time of return to full physical fitness. Extension and flexion torques were measured for the injured and healthy limbs at two angular velocities approximately 1.5 months before the surgery and 3, 6, and 12 months after ACLR. Significant differences (p ≤ 0.05) in peak knee extension and flexion torques, hamstring/quadriceps (H/Q) strength ratios, uninvolved/involved limb peak torque ratios, and the normalized work of these muscles between the four stages of rehabilitation were identified. Significant differences between extension peak torques for the injured and healthy limbs were also detected at all stages. The obtained results showed that 12 months of rehabilitation were insufficient for the involved knee joint to recover its strength to the level of strength of the uninvolved knee joint. The results helped to evaluate the progress of the rehabilitation and to implement necessary modifications optimizing the rehabilitation training program. The results of the study may also be used as referential data for physically active males of similar age. PMID:26646385
Effects of 17-day spaceflight on knee extensor muscle function and size
NASA Technical Reports Server (NTRS)
Tesch, Per A.; Berg, Hans E.; Bring, Daniel; Evans, Harlan J.; LeBlanc, Adrian D.
2005-01-01
It is generally held that space travelers experience muscle dysfunction and atrophy during exposure to microgravity. However, observations are scarce and reports somewhat inconsistent with regard to the time course, specificity and magnitude of such changes. Hence, we examined four male astronauts (group mean approximately 43 years, 86 kg and 183 cm) before and after a 17-day spaceflight (Space Transport System-78). Knee extensor muscle function was measured during maximal bilateral voluntary isometric and iso-inertial concentric, and eccentric actions. Cross-sectional area (CSA) of the knee extensor and flexor, and gluteal muscle groups was assessed by means of magnetic resonance imaging. The decrease in strength (P<0.05) across different muscle actions after spaceflight amounted to 10%. Eight ambulatory men, examined on two occasions 20 days apart, showed unchanged (P>0.05) muscle strength. CSA of the knee extensor and gluteal muscles, each decreased (P<0.05) by 8%. Knee flexor muscle CSA showed no significant (P>0.05) change. The magnitude of these changes concord with earlier results from ground-based studies of similar duration. The results of this study, however, do contrast with the findings of no decrease in maximal voluntary ankle plantar flexor force previously reported in the same crew.
Special features of total knee replacement in hemophilia.
Rodriguez-Merchan, Emerito Carlos
2013-12-01
Total knee replacement is an operation frequently needed by hemophilia patients, which greatly improves their quality of life. This operation, however, carries a higher risk of bleeding and infection for hemophiliacs than it does for osteoarthritis sufferers. It is advisable to implant prosthetic components using antibiotic-loaded cement. It is essential to maintain a level of 100% of the replacement clotting factor for 2 weeks. Hematological treatment must be established, depending on the patient's factor levels and other pharmacokinetic parameters such as recovery and half-life, optimal doses and treatment time. It is preferable to use general anesthesia due to the risk of spinal bleeding. The lifespan of total knee replacement in hemophilic patients is shorter than in patients with osteoarthritis because of the increased risk of infection.
Zhang, Xiangmin; Williams, Rachel; Wu, Xiaodong; Anderson, Donald D.; Sonka, Milan
2011-01-01
A novel method for simultaneous segmentation of multiple interacting surfaces belonging to multiple interacting objects, called LOGISMOS (layered optimal graph image segmentation of multiple objects and surfaces), is reported. The approach is based on the algorithmic incorporation of multiple spatial inter-relationships in a single n-dimensional graph, followed by graph optimization that yields a globally optimal solution. The LOGISMOS method’s utility and performance are demonstrated on a bone and cartilage segmentation task in the human knee joint. Although trained on only a relatively small number of nine example images, this system achieved good performance. Judged by dice similarity coefficients (DSC) using a leave-one-out test, DSC values of 0.84 ± 0.04, 0.80 ± 0.04 and 0.80 ± 0.04 were obtained for the femoral, tibial, and patellar cartilage regions, respectively. These are excellent DSC values, considering the narrow-sheet character of the cartilage regions. Similarly, low signed mean cartilage thickness errors were obtained when compared to a manually-traced independent standard in 60 randomly selected 3-D MR image datasets from the Osteoarthritis Initiative database—0.11 ± 0.24, 0.05 ± 0.23, and 0.03 ± 0.17 mm for the femoral, tibial, and patellar cartilage thickness, respectively. The average signed surface positioning errors for the six detected surfaces ranged from 0.04 ± 0.12 mm to 0.16 ± 0.22 mm. The reported LOGISMOS framework provides robust and accurate segmentation of the knee joint bone and cartilage surfaces of the femur, tibia, and patella. As a general segmentation tool, the developed framework can be applied to a broad range of multiobject multisurface segmentation problems. PMID:20643602
Forte, Roberta; Pesce, Caterina; Leite, Joao Costa; De Vito, Giuseppe; Gibney, Eileen R; Tomporowski, Phillip D; Boreham, Colin A G
2013-06-01
Both physical and cognitive factors are known to independently predict functional mobility in older people. However, the combined predictive value of both physical fitness and cognitive factors on functional mobility has been less investigated. The aim of the present study was to assess if cognitive executive functions moderate the role of physical fitness in determining functional mobility of older individuals. Fifty-seven 65- to 75-year-old healthy participants performed tests of functional mobility (habitual and maximal walking speed, maximal walking speed while picking up objects/stepping over obstacles), physical fitness (peak power, knee extensors torque, back/lower limb flexibility, aerobic fitness), and executive function (inhibition and cognitive flexibility). Maximal walking speeds were predicted by physical fitness parameters and their interaction with cognitive factors. Knee extensor torque emerged as the main predictor of all tested locomotor performances at maximal speed. The effect of peak power and back/lower limb flexibility was moderated by executive functions. In particular, inhibition and cognitive flexibility differed in the way in which they moderate the role of fitness. High levels of cognitive flexibility seem necessary to take advantage of leg power for walking at maximal speed. In contrast, high levels of inhibitory capacity seem to compensate for low levels of back/lower limb flexibility when picking up movements are added to a locomotor task. These findings may have important practical implications for the design and implementation of multi-component training programs aimed at optimizing functional abilities in older adults.
Repair of Medial Patellofemoral, Ligament Improves Patellar, Tracking in Total Knee Replacement.
Meneghini, R Michael; Ziemba-Davis, Mary; Smits, Shelly; Bicos, James
2015-11-01
The medial patellofemoral ligament (MPFL) is essential to maintain patella stability; however, its role in total knee replacement (TKR) has not been studied. Forty-six consecutive TKRs in 40 patients were reviewed. Standard closure was performed in 29 TKRs. The MPFL was isolated and anatomically re-approximated in 17 subsequent TKRs. Blinded radiographic evaluation of patellar tilt and subluxation was performed preoperatively and 4 months postoperatively. Despite greater preoperative lateral tilt, the MPFL repair group demonstrated greater correction in patellar tilt compared with the standard closure group (p = 0.02). Patellar tracking also was optimized in the MPFL group, despite equivalent preoperative lateral patellar subluxation in the two groups. Simple repair of the MPFL at arthrotomy closure appears to optimize patellar stability radiographically and may improve long-term results by minimizing patellar complications and wear.
Wehling, Peter; Moser, Carsten; Maixner, William
2016-01-01
The objectives of osteoarthritis (OA) management are to reduce pain and inflammation, slow cartilage degradation, improve function and reduce disability. Current strategies for managing knee OA include nonpharmacological interventions, oral pharmacological treatments, localized intra-articular injections, and surgery. It has become evident that the inflammatory response is a key contributor to the development and progression of knee OA. Signaling pathways involving growth factors and cytokines are being investigated for the development of new therapies that target the underlying biological processes causing the disease. This concept of ‘molecular orthopedics’ enables more patient-centered diagnostic and treatment strategies. In contrast to other conservative therapies, which ultimately only address OA symptoms, intra-articular injections, in particular autologous conditioned serum (ACS), provide benefits that have the potential to outweigh those of established pharmacological treatments and surgery. Surgery has historically been considered the final solution for treatment of knee OA, both by treating physicians and by patients; however, there are increasing concerns regarding the lack of randomized clinical trials providing evidence to support this opinion. Intra-articular injection of ACS has demonstrated efficacy as a treatment for knee OA in a number of studies, with a very low rate of adverse events and side effects, compared with surgery. Treatment with ACS utilizes the release of anti-inflammatory cytokines and regenerative growth factors to support the natural healing processes in the knee, and has the potential to provide a valuable alternative to surgical intervention. PMID:27247634
Verschueren, J; van Tiel, J; Reijman, M; Bron, E E; Klein, S; Verhaar, J A N; Bierma-Zeinstra, S M A; Krestin, G P; Wielopolski, P A; Oei, E H G
2017-09-01
To evaluate the possibility of assessing knee cartilage with T2-mapping and delayed gadolinium enhanced magnetic resonance imaging (MRI) of cartilage (dGEMRIC) in one post-contrast MR examination at 3 Tesla (T). T2 mapping was performed in 10 healthy volunteers at baseline; directly after baseline; after 10 min of cycling; and after 90 min delay, and in 16 osteoarthritis patients before and after intravenous administration of a double dose gadolinium dimeglumine contrast agent, reflecting key dGEMRIC protocol elements. Differences in T2 relaxation times between each timepoint and baseline were calculated for 6 cartilage regions using paired t tests or Wilcoxon signed-rank tests and the smallest detectable change (SDC). After cycling, a significant change in T2 relaxation times was found in the lateral weight-bearing tibial plateau (+1.0 ms, P = 0.04). After 90 min delay, significant changes were found in the lateral weight-bearing femoral condyle (+1.2 ms, P = 0.03) and the lateral weight-bearing tibial plateau (+1.3 ms, P = 0.01). In these regions of interests (ROIs), absolute differences were small and lower than the corresponding SDCs. T2-mapping after contrast administration only showed statistically significantly lower T2 relaxation times in the medial posterior femoral condyle (-2.4 ms, P < 0.001) with a change exceeding the SDC. Because dGEMRIC protocol elements resulted in only small differences in T2 relaxation times that were not consistent and lower than the SDC in the majority of regions, our results suggest that T2-mapping and dGEMRIC can be performed reliably in a single imaging session to assess cartilage biochemical composition in knee osteoarthritis (OA) at 3 T. Copyright © 2017 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Staphylococcus aureus infections following knee and hip prosthesis insertion procedures.
Arduino, Jean Marie; Kaye, Keith S; Reed, Shelby D; Peter, Senaka A; Sexton, Daniel J; Chen, Luke F; Hardy, N Chantelle; Tong, Steven Yc; Smugar, Steven S; Fowler, Vance G; Anderson, Deverick J
2015-01-01
Staphylococcus aureus is the most common and most important pathogen following knee and hip arthroplasty procedures. Understanding the epidemiology of invasive S. aureus infections is important to quantify this serious complication. This nested retrospective cohort analysis included adult patients who had undergone insertion of knee or hip prostheses with clean or clean-contaminated wound class at 11 hospitals between 2003-2006. Invasive S. aureus infections, non-superficial incisional surgical site infections (SSIs) and blood stream infections (BSIs), were prospectively identified following each procedure. Prevalence rates, per 100 procedures, were estimated. 13,719 prosthetic knee (62%) and hip (38%) insertion procedures were performed. Of 92 invasive S. aureus infections identified, SSIs were more common (80%) than SSI and BSI (10%) or BSI alone (10%). The rate of invasive S. aureus infection/100 procedures was 0.57 [95% CI: 0.43-0.73] for knee insertion and 0.83 [95% CI: 0.61-1.08] for hip insertion. More than half (53%) were methicillin-resistant. Median time-to-onset of infection was 34 and 26 days for knee and hip insertion, respectively. Infection was associated with higher National Healthcare Safety Network risk index (p ≤ 0.0001). Post-operative invasive S. aureus infections were rare, but difficult-to-treat methicillin-resistant infections were relatively common. Optimizing preventative efforts may greatly reduce the healthcare burden associated with S. aureus infections.
Qiu, Shuang; Feng, Jing; Xu, Jiapeng; Xu, Rui; Zhao, Xin; Zhou, Peng; Qi, Hongzhi; Zhang, Lixin; Ming, Dong
2017-01-01
Neuromuscular electrical stimulation (NMES) that stimulates skeletal muscles to induce contractions has been widely applied to restore functions of paralyzed muscles. However, the architectural changes of stimulated muscles induced by NMES are still not well understood. The present study applies sonomyography (SMG) to evaluate muscle architecture under NMES-induced and voluntary movements. The quadriceps muscles of seven healthy subjects were tested for eight cycles during an extension exercise of the knee joint with/without NMES, and SMG and the knee joint angle were recorded during the process of knee extension. A least squares support vector machine (LS-SVM) LS-SVM model was developed and trained using the data sets of six cycles collected under NMES, while the remaining data was used to test. Muscle thickness changes were extracted from ultrasound images and compared between NMES-induced and voluntary contractions, and LS-SVM was used to model a relationship between dynamical knee joint angles and SMG signals. Muscle thickness showed to be significantly correlated with joint angle in NMES-induced contractions, and a significant negative correlation was observed between Vastus intermedius (VI) thickness and rectus femoris (RF) thickness. In addition, there was a significant difference between voluntary and NMES-induced contractions . The LS-SVM model based on RF thickness and knee joint angle provided superior performance compared with the model based on VI thickness and knee joint angle or total thickness and knee joint angle. This suggests that a strong relation exists between the RF thickness and knee joint angle. These results provided direct evidence for the potential application of RF thickness in optimizing NMES system as well as measuring muscle state under NMES.
Indium-111 leukocyte imaging in patients with rheumatoid arthritis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uno, K.; Matsui, N.; Nohira, K.
1986-03-01
This study evaluates the usefulness of labeled leukocyte imaging in patients with rheumatoid arthritis. In 33 patients, the incidence of pain and swelling in 66 wrist joints and 66 knee joints was compared with the accumulation of (/sup 111/In)leukocytes. No accumulation of (/sup 111/In)leukocytes was seen in any of the patients' wrists (0/12) or knee joints (0/14) when both pain and swelling were absent. In contrast, 93% (25/27) of wrist joints and 80% (24/30) of knee joints with both pain and swelling were positive by (/sup 111/In)leukocyte scintigraphy. There was little correlation between the stage of the disease, as determinedmore » by radiography, and (/sup 111/In)leukocyte accumulation. This study suggests that (/sup 111/In)leukocyte imaging may be a reliable procedure for monitoring the activity of rheumatoid arthritis, especially for confirming the lack of an ongoing inflammatory response.« less
Regional or general anesthesia for fast-track hip and knee replacement - what is the evidence?
Kehlet, Henrik; Aasvang, Eske Kvanner
2015-01-01
Regional anesthesia for knee and hip arthroplasty may have favorable outcome effects compared with general anesthesia by effectively blocking afferent input, providing initial postoperative analgesia, reducing endocrine metabolic responses, and providing sympathetic blockade with reduced bleeding and less risk of thromboembolic complications but with undesirable effects on lower limb motor and urinary bladder function. Old randomized studies supported the use of regional anesthesia with fewer postoperative pulmonary and thromboembolic complications, and this has been supported by recent large non-randomized epidemiological database cohort studies. In contrast, the data from newer randomized trials are conflicting, and recent studies using modern general anesthetic techniques may potentially support the use of general versus spinal anesthesia. In summary, the lack of properly designed large randomized controlled trials comparing modern general anesthesia and spinal anesthesia for knee and hip arthroplasty prevents final recommendations and calls for prospective detailed studies in this clinically important field. PMID:26918127
Liu, Fang; Zhou, Zhaoye; Jang, Hyungseok; Samsonov, Alexey; Zhao, Gengyan; Kijowski, Richard
2018-04-01
To describe and evaluate a new fully automated musculoskeletal tissue segmentation method using deep convolutional neural network (CNN) and three-dimensional (3D) simplex deformable modeling to improve the accuracy and efficiency of cartilage and bone segmentation within the knee joint. A fully automated segmentation pipeline was built by combining a semantic segmentation CNN and 3D simplex deformable modeling. A CNN technique called SegNet was applied as the core of the segmentation method to perform high resolution pixel-wise multi-class tissue classification. The 3D simplex deformable modeling refined the output from SegNet to preserve the overall shape and maintain a desirable smooth surface for musculoskeletal structure. The fully automated segmentation method was tested using a publicly available knee image data set to compare with currently used state-of-the-art segmentation methods. The fully automated method was also evaluated on two different data sets, which include morphological and quantitative MR images with different tissue contrasts. The proposed fully automated segmentation method provided good segmentation performance with segmentation accuracy superior to most of state-of-the-art methods in the publicly available knee image data set. The method also demonstrated versatile segmentation performance on both morphological and quantitative musculoskeletal MR images with different tissue contrasts and spatial resolutions. The study demonstrates that the combined CNN and 3D deformable modeling approach is useful for performing rapid and accurate cartilage and bone segmentation within the knee joint. The CNN has promising potential applications in musculoskeletal imaging. Magn Reson Med 79:2379-2391, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Roth, Christopher J; Boll, Daniel T; Wall, Lisa K; Merkle, Elmar M
2010-08-01
The purpose of this investigation was to assess workflow for medical imaging studies, specifically comparing liver and knee MRI examinations by use of the Lean Six Sigma methodologic framework. The hypothesis tested was that the Lean Six Sigma framework can be used to quantify MRI workflow and to identify sources of inefficiency to target for sequence and protocol improvement. Audio-video interleave streams representing individual acquisitions were obtained with graphic user interface screen capture software in the examinations of 10 outpatients undergoing MRI of the liver and 10 outpatients undergoing MRI of the knee. With Lean Six Sigma methods, the audio-video streams were dissected into value-added time (true image data acquisition periods), business value-added time (time spent that provides no direct patient benefit but is requisite in the current system), and non-value-added time (scanner inactivity while awaiting manual input). For overall MRI table time, value-added time was 43.5% (range, 39.7-48.3%) of the time for liver examinations and 89.9% (range, 87.4-93.6%) for knee examinations. Business value-added time was 16.3% of the table time for the liver and 4.3% of the table time for the knee examinations. Non-value-added time was 40.2% of the overall table time for the liver and 5.8% for the knee examinations. Liver MRI examinations consume statistically significantly more non-value-added and business value-added times than do knee examinations, primarily because of respiratory command management and contrast administration. Workflow analyses and accepted inefficiency reduction frameworks can be applied with use of a graphic user interface screen capture program.
Geith, Tobias; Brun, Emmanuel; Mittone, Alberto; Gasilov, Sergei; Weber, Loriane; Adam-Neumair, Silvia; Bravin, Alberto; Reiser, Maximilian; Coan, Paola; Horng, Annie
2018-06-01
The aim of this study was to quantitatively assess hyaline cartilage and subchondral bone conditions in a fully preserved cadaveric human knee joint using high-resolution x-ray propagation-based phase-contrast imaging (PBI) CT and to compare the performance of the new technique with conventional CT and MRI. A cadaveric human knee was examined using an x-ray beam of 60 keV, a detector with a 90-mm 2 FOV, and a pixel size of 46 × 46 μm 2 . PBI CT images were reconstructed with both the filtered back projection algorithm and the equally sloped tomography method. Conventional 3-T MRI and CT were also performed. Measurements of cartilage thickness, cartilage lesions, International Cartilage Repair Society scoring, and detection of subchondral bone changes were evaluated. Visual inspection of the specimen akin to arthroscopy was conducted and served as a standard of reference for lesion detection. Loss of cartilage height was visible on PBI CT and MRI. Quantification of cartilage thickness showed a strong correlation between the two modalities. Cartilage lesions appeared darker than the adjacent cartilage on PBI CT. PBI CT showed similar agreement to MRI for depicting cartilage substance defects or lesions compared with the visual inspection. The assessment of subchondral bone cysts showed moderate to strong agreement between PBI CT and CT. In contrast to the standard clinical methods of MRI and CT, PBI CT is able to simultaneously depict cartilage and bony changes at high resolution. Though still an experimental technique, PBI CT is a promising high-resolution imaging method to evaluate comprehensive changes of osteoarthritic disease in a clinical setting.
Anifah, Lilik; Purnama, I Ketut Eddy; Hariadi, Mochamad; Purnomo, Mauridhi Hery
2013-01-01
Localization is the first step in osteoarthritis (OA) classification. Manual classification, however, is time-consuming, tedious, and expensive. The proposed system is designed as decision support system for medical doctors to classify the severity of knee OA. A method has been proposed here to localize a joint space area for OA and then classify it in 4 steps to classify OA into KL-Grade 0, KL-Grade 1, KL-Grade 2, KL-Grade 3 and KL-Grade 4, which are preprocessing, segmentation, feature extraction, and classification. In this proposed system, right and left knee detection was performed by employing the Contrast-Limited Adaptive Histogram Equalization (CLAHE) and the template matching. The Gabor kernel, row sum graph and moment methods were used to localize the junction space area of knee. CLAHE is used for preprocessing step, i.e.to normalize the varied intensities. The segmentation process was conducted using the Gabor kernel, template matching, row sum graph and gray level center of mass method. Here GLCM (contrast, correlation, energy, and homogeinity) features were employed as training data. Overall, 50 data were evaluated for training and 258 data for testing. Experimental results showed the best performance by using gabor kernel with parameters α=8, θ=0, Ψ=[0 π/2], γ=0,8, N=4 and with number of iterations being 5000, momentum value 0.5 and α0=0.6 for the classification process. The run gave classification accuracy rate of 93.8% for KL-Grade 0, 70% for KL-Grade 1, 4% for KL-Grade 2, 10% for KL-Grade 3 and 88.9% for KL-Grade 4.
Anifah, Lilik; Purnama, I Ketut Eddy; Hariadi, Mochamad; Purnomo, Mauridhi Hery
2013-01-01
Localization is the first step in osteoarthritis (OA) classification. Manual classification, however, is time-consuming, tedious, and expensive. The proposed system is designed as decision support system for medical doctors to classify the severity of knee OA. A method has been proposed here to localize a joint space area for OA and then classify it in 4 steps to classify OA into KL-Grade 0, KL-Grade 1, KL-Grade 2, KL-Grade 3 and KL-Grade 4, which are preprocessing, segmentation, feature extraction, and classification. In this proposed system, right and left knee detection was performed by employing the Contrast-Limited Adaptive Histogram Equalization (CLAHE) and the template matching. The Gabor kernel, row sum graph and moment methods were used to localize the junction space area of knee. CLAHE is used for preprocessing step, i.e.to normalize the varied intensities. The segmentation process was conducted using the Gabor kernel, template matching, row sum graph and gray level center of mass method. Here GLCM (contrast, correlation, energy, and homogeinity) features were employed as training data. Overall, 50 data were evaluated for training and 258 data for testing. Experimental results showed the best performance by using gabor kernel with parameters α=8, θ=0, Ψ=[0 π/2], γ=0,8, N=4 and with number of iterations being 5000, momentum value 0.5 and α0=0.6 for the classification process. The run gave classification accuracy rate of 93.8% for KL-Grade 0, 70% for KL-Grade 1, 4% for KL-Grade 2, 10% for KL-Grade 3 and 88.9% for KL-Grade 4. PMID:23525188
NASA Astrophysics Data System (ADS)
Shim, Hackjoon; Kwoh, C. Kent; Yun, Il Dong; Lee, Sang Uk; Bae, Kyongtae
2009-02-01
Osteoarthritis (OA) is associated with degradation of cartilage and related changes in the underlying bone. Quantitative measurement of those changes from MR images is an important biomarker to study the progression of OA and it requires a reliable segmentation of knee bone and cartilage. As the most popular method, manual segmentation of knee joint structures by boundary delineation is highly laborious and subject to user-variation. To overcome these difficulties, we have developed a semi-automated method for segmentation of knee bones, which consisted of two steps: placement of seeds and computation of segmentation. In the first step, seeds were placed by the user on a number of slices and then were propagated automatically to neighboring images. The seed placement could be performed on any of sagittal, coronal, and axial planes. The second step, computation of segmentation, was based on a graph-cuts algorithm where the optimal segmentation is the one that minimizes a cost function, which integrated the seeds specified by the user and both the regional and boundary properties of the regions to be segmented. The algorithm also allows simultaneous segmentation of three compartments of the knee bone (femur, tibia, patella). Our method was tested on the knee MR images of six subjects from the osteoarthritis initiative (OAI). The segmentation processing time (mean+/-SD) was (22+/-4)min, which is much shorter than that by the manual boundary delineation method (typically several hours). With this improved efficiency, our segmentation method will facilitate the quantitative morphologic analysis of changes in knee bones associated with osteoarthritis.
Riley, Thomas C; Mafi, Reza; Mafi, Pouya; Khan, Wasim S
2018-02-23
The incidence of knee ligament injury is increasing and represents a significant cost to healthcare providers. Current interventions include tissue grafts, suture repair and non-surgical management. These techniques have demonstrated good patient outcomes but have been associated graft rejection, infection, long term immobilization and reduced joint function. The limitations of traditional management strategies have prompted research into tissue engineering of knee ligaments. This paper aims to evaluate whether tissue engineering of knee ligaments offers a viable alternative in the clinical management of knee ligament injuries. A search of existing literature was performed using OVID Medline, Embase, AMED, PubMed and Google Scholar, and a manual review of citations identified within these papers. Silk, polymer and extracellular matrix based scaffolds can all improve graft healing and collagen production. Fibroblasts and stem cells demonstrate compatibility with scaffolds, and have been shown to increase organized collagen production. These effects can be augmented using growth factors and extracellular matrix derivatives. Animal studies have shown tissue engineered ligaments can provide the biomechanical characteristics required for effective treatment of knee ligament injuries. There is a growing clinical demand for a tissue engineered alternative to traditional management strategies. Currently, there is limited consensus regarding material selection for use in tissue engineered ligaments. Further research is required to optimize tissue engineered ligament production before clinical application. Controlled clinical trials comparing the use of tissue engineered ligaments and traditional management in patients with knee ligament injury could determine whether they can provide a cost-effective alternative. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Qiu, Bing; Liu, Fei; Tang, Bensen; Deng, Biyong; Liu, Fang; Zhu, Weimin; Zhen, Dong; Xue, Mingyuan; Zhang, Mingjiao
2017-10-01
Patient-specific instrumentation (PSI) was designed to improve the accuracy of preoperative planning and postoperative prosthesis positioning in total knee arthroplasty (TKA). However, better understanding needs to be achieved due to the subtle nature of the PSI systems. In this study, 3D printing technique based on the image data of computed tomography (CT) has been utilized for optimal controlling of the surgical parameters. Two groups of TKA cases have been randomly selected as PSI group and control group with no significant difference of age and sex ( p > 0.05). The PSI group is treated with 3D printed cutting guides whereas the control group is treated with conventional instrumentation (CI). By evaluating the proximal osteotomy amount, distal osteotomy amount, valgus angle, external rotation angle, and tibial posterior slope angle of patients, it can be found that the preoperative quantitative assessment and intraoperative changes can be controlled with PSI whereas CI is relied on experience. In terms of postoperative parameters, such as hip-knee-ankle (HKA), frontal femoral component (FFC), frontal tibial component (FTC), and lateral tibial component (LTC) angles, there is a significant improvement in achieving the desired implant position ( p < 0.05). Assigned from the morphology of patients' knees, the PSI represents the convergence of congruent designs with current personalized treatment tools. The PSI can achieve less extremity alignment and greater accuracy of prosthesis implantation compared against control method, which indicates potential for optimal HKA, FFC, and FTC angles. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
The design and pre-clinical evaluation of knee replacements for osteoarthritis.
Walker, Peter S
2015-03-18
One of the concepts that Rik Huiskes promoted was that implants such as knee and hip replacements could be analyzed and optimized using numerical models such as finite element analysis, or by experimental testing, an area he called pre-clinical testing. The design itself could be formulated or improved by defining a specific goal or asking a key question. These propositions are examined in the light of almost five decades of experience with knee implants. Achieving the required laxity and stability, was achieved by attempting to reproduce anatomical values by suitable radii of curvature and selective ligament retention. Obtaining durable fixation was based on testing many configurations to obtain the most uniform stress distribution at the implant-bone interface. Achieving the best overall kinematics has yet to be fully solved due to the variations in activities and patients. These and many other factors have usually been addressed individually rather than as a composite, although as time has gone on, successful features have gradually been assimilated into most designs. But even a systematic approach has been flawed because some unrecognized response was not accounted for in the pre-clinical model, a limitation of models in general. In terms of the design process, so far no method has emerged for systematically reaching an optimal solution from all aspects, although this is possible in principle. Overall however, predictive numerical or physical models should be an essential element in the design of new or improved knee replacements, a part of the design process itself. Copyright © 2015. Published by Elsevier Ltd.
Ristanis, Stavros; Tsepis, Elias; Giotis, Dimitrios; Stergiou, Nicholas; Cerulli, Guiliano; Georgoulis, Anastasios D
2009-11-01
Changes in electromechanical delay during muscle activation are expected when there are substantial alterations in the structural properties of the musculotendinous tissue. In anterior cruciate ligament reconstruction, specific tendons are being harvested for grafts. Thus, there is an associated scar tissue development at the tendon that may affect the corresponding electromechanical delay. This study was conducted to investigate whether harvesting of semitendinosus and gracilis tendons for anterior cruciate ligament reconstruction will affect the electromechanical delay of the knee flexors. Case-control study; Level of evidence, 3. The authors evaluated 12 patients with anterior cruciate ligament reconstruction with a semitendinosus and gracilis autograft, 2 years after the reconstruction, and 12 healthy controls. Each participant performed 4 maximally explosive isometric contractions with a 1-minute break between contractions. The surface electromyographic activity of the biceps femoris and the semitendinosus was recorded from both legs during the contractions. The statistical comparisons revealed significant increases of the electromechanical delay of the anterior cruciate ligament-reconstructed knee for both investigated muscles. Specifically, the electromechanical delay values were increased for both the biceps femoris (P = .029) and the semitendinosus (P = .005) of the reconstructed knee when compared with the intact knee. Comparing the anterior cruciate ligament-reconstructed knee against healthy controls revealed similar significant differences for both muscles (semitendinosus, P = .011; biceps femoris, P = .024). The results showed that harvesting the semitendinosus and gracilis tendons for anterior cruciate ligament reconstruction significantly increased the electromechanical delay of the knee flexors. Increased hamstring electromechanical delay might impair knee safety and performance by modifying the transfer time of muscle tension to the tibia and therefore affecting muscle response during sudden movements in athletic activities. However, further investigation is required to identify whether the increased electromechanical delay of the hamstrings can actually influence optimal sports performance and increase the risk for knee injury in athletes with anterior cruciate ligament reconstructions.
[Design of an external prosthetic system with a polycentric mechanism].
Valentino Orozco, Gerardo Alejandro; Guerrero Beltrán, Leobardo; Obregón Velasco, Dinora; Avalos Fernández, Oscar
2008-01-01
This medical and engineering work explains the process carried out to build a four-barred polycentric knee mechanism using a mechanical actuator for modular prosthetics. Imitation of the knee performance was the main goal, as well as to cover the basic needs of amputated patients with a low production cost. The polycentric knee mechanism was developed in three stages. The first one was the design and building of the four-barred mechanism using materials as stainless steel 304 and aluminum 6,061 which both have high reliability, corrosion resistance and a relatively easy modeling capability. The total mass was of 700 g. Autocad was used for design and effort analysis was done by using ANSYS. At the end of the first stage, it was observed that its density did not allow mass optimization and no assistant actuator was available for the walking movement. In the second stage, mechanism mass estimation was done by using Alumold 400; this material brings lower density than stainless steel keeping strength and fatigue resistance higher than aluminum 6061. The better ergonomic device was built; a mechanical actuator based on a spring was implemented and tested on two female patients, one geriatric and one 16 years old. The third stage will be described in a future publication, the device mass was optimized by using poly-tetra-fluor-ethylene enhanced with carbon and carbon fiber. Also, the mechanical actuator was complemented with reo-magnetic liquid addition and an electronic control. At the end of this research, an external polycentric knee mechanism was developed, by observing movement stages, velocities, ergonomics, shapes, sizes and significant weights of Mexican patients. Effort analysis by finite element was done and it was determined that the mechanism was capable of modifying its center of rotation according to the knee flexion angle making it a polycentric mechanisms. Also, it was tested on two patients, both females, one 16 and one 75 years old.
Spahn, G; Grosser, V; Schiltenwolf, M; Schröter, F; Grifka, J
2015-03-01
Aim and Hyopthesis: This systematic review and the metanalysis were performed to investigate the relation between football activity and the potential risk of knee osteoarthritis (possible occupational disease). It was hypothesised that soccer players suffer more than controls from knee osteoarthritis also in cases with an absence of documented major injuries. The review and the metaanalysis were performed accordingly to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. On 2014.02.01 a search was conducted within the medical databases PubMed, Medline, Cochrane, EMBASE und Web-of-Science. A total of 4,649 papers underwent a "Title-Abstract-Review". Finally 6 publications were included in the metaanaylsis. There were no longitudinal community-based studies as well as no Cochrane Reviews regarding the risk of knee osteoarthritis in soccer players. After adjustment of major injuries of the knee, soccer players have a slightly increased risk for knee osteoarthritis: relative risk 1.3 (95 % CI 1.0 - 1.7); I(2) = 37.4 %; p = 0.002. In contrast, in studies without differentiation of injured and non-injured knees, the relative risk was significantly increased: 2.9 (95 % CI 2.0 - 4.1); I(2) = 56.3 %; p < 0.001. Soccer players are a very heterogeneous group. The soccer player's knee undergoes different loadings including minor and major injuries. But the individual load also strongly depends on the player's status, his position within the football field and many other factors. In the absence of a major trauma the soccer player has only a slightly increased risk for the development of osteoarthritis. Thus we conclude that an injury in professional football does not fulfil the characteristics of an occupational disease. © Georg Thieme Verlag KG Stuttgart · New York.
Predictors of degenerative medial meniscus extrusion: radial component and knee osteoarthritis.
Lee, Dae-Hee; Lee, Bum-Sik; Kim, Jong-Min; Yang, Kyung-Sook; Cha, Eun-Jong; Park, Ji-Hun; Bin, Seong-Il
2011-02-01
the purpose of this study was to determine the effect of a radial tear on degenerative medial meniscus posterior horn tear extrusion and to identify predictors of medial meniscus extrusion. we reviewed the records of 102 knees with medial meniscus posterior horn tears and degeneration that underwent a partial meniscectomy. Tears were classified as root (n = 17) and non-root (n = 85) tears, or as radial (n = 46) and non-radial (n = 56) tears. Groups were compared in terms of absolute and relative meniscal extrusion, and the proportion of knees with major (> 3 mm) extrusion. Multiple regression analysis was used to identify predictors of extrusion. the radial group had greater mean absolute (4 ± 1 vs. 3 ± 1 mm, P = 0.001) and relative (31 ± 11 vs. 23 ± 12%, P = 0.031) extrusion than the non-radial group. The radial group also had a greater proportion of major extrusions than the non-radial group (74% vs. 26%; P = 0.016). In contrast, the root tear and non-root tear groups were similar in terms of mean absolute (3 ± 1 vs. 3 ± 1 mm, P = n.s.) and relative (30 ± 7 vs. 26 ± 13%; P = n.s.) extrusion and in terms of proportion with major extrusions (59 vs. 55%; P = n.s.). Extrusion was found to be associated with a similar strength with both the presence of a radial component and the preoperative Kellgren-Lawrence grade. meniscal extrusion was greater and more severe in knees with a radial tear component than in knees without a radial component. The incidence and degree of major extrusion was similar in knees with root tears and non-root tears. A radial component and knee osteoarthritis severity were similarly predictive of absolute and relative extrusion. Meniscal extrusion in osteoarthritic knees was associated not only with degenerative meniscal tear but also with osteoarthritis severity. Therefore, arthroscopic meniscal procedures, especially meniscal repair, should be cautiously considered in patients with meniscal extrusion.
Multi-Axis Prosthetic Knee Resembles Alpine Skiing Movements of an Intact Leg
Demšar, Ivan; Duhovnik, Jože; Lešnik, Blaž; Supej, Matej
2015-01-01
The purpose of the study was to analyse the flexion angles of the ski boot, ankle and knee joints of an above-knee prosthesis and to compare them with an intact leg and a control group of skiers. One subject with an above-knee amputation of the right leg and eight healthy subjects simulated the movement of a skiing turn by performing two-leg squats in laboratory conditions. By adding additional loads in proportion to body weight (BW; +1/3 BW, +2/3 BW, +3/3 BW), various skiing regimes were simulated. Change of Flexion Angle (CoFA) and Range of Motion (RoM) in the ski boot, ankle and knee joints were calculated and compared. An average RoM in the skiing boot on the side of prosthesis (4.4 ± 1.1°) was significantly lower compared to an intact leg (5.9 ± 1.8°) and the control group (6.5 ± 2.3°). In the ankle joint, the average RoM was determined to be 13.2±2.9° in the prosthesis, 12.7 ± 2.8° in an intact leg and 14.8±3.6 in the control group. However, the RoM of the knee joint in the prosthesis (42.2 ± 4.2°) was significantly larger than that of the intact leg (34.7 ± 4.4°). The average RoM of the knee joint in the control group was 47.8 ± 5.4°. The influences of additional loads on the kinematics of the lower extremities were different on the side of the prosthesis and on the intact leg. In contrast, additional loads did not produce any significant differences in the control group. Although different CoFAs in the ski boot, ankle and knee joints were used, an above-knee prosthesis with a built-in multi-axis prosthetic knee enables comparable leg kinematics in simulated alpine skiing. Key points The RoM in the ski boot on the side of the prosthetic leg was smaller than the RoM of the intact leg and the control group of healthy subjects. The RoM in the ankle joint of prosthetic leg was comparable to that of the intact leg and the control group of healthy subjects. The RoM in the prosthetic knee joint was greater than the RoM in the knee joint of the intact leg and smaller than that of the control group. The total knee flexions in the laboratory measurements were comparable with field measurements. Additional load affects the RoM of the ski boot, ankle and knee joints for the amputated skier in both legs. No significant influence from the additional load was found on the RoM in the control group of healthy subjects. The above-knee prosthesis with a multiple-axis prosthetic knee reproduces the alpine skiing kinematics of an intact leg. PMID:26664282
Breakout session: Gender disparities in knee osteoarthritis and TKA.
O'Connor, Mary I; Hooten, Elizabeth Gerken
2011-07-01
Biologically derived (sex-based) and behaviorally influenced (gender-based) disparities exist in knee osteoarthritis and treatment with TKA. We sought to highlight sex- and gender-based differences with respect to knee osteoarthritis and its treatment. Our purposes were to (1) define where we are now, (2) outline where we need to go, and (3) generate solutions to how we can get there. WHERE ARE WE NOW?: A growing body of evidence shows sex- and gender-based disparities contribute to differences in the incidence, treatment, and outcomes of patients with knee osteoarthritis. Moreover, the influence of unconscious provider bias in disparities in care is becoming recognized. WHERE DO WE NEED TO GO?: Sex- and gender-based differences need to be identified and translated into clinical practice to effect patient-centered sex- and gender-based medicine. Equitable and evidence-based care must be provided. HOW DO WE GET THERE?: Research must continue to focus on sex-based differences in cartilage degeneration and gender-related factors influencing the development and progression of knee osteoarthritis. Development of evidence-based guidelines for optimal timing of TKA would assist patients and clinicians with surgical decision-making. Training of healthcare providers to mitigate again unconscious basis is essential. Care must be patient-focused, with patients empowered to be full partners with providers in healthcare outcomes.
Acute Infection in Total Knee Arthroplasty: Diagnosis and Treatment
Martínez-Pastor, Juan Carlos; Maculé-Beneyto, Francisco; Suso-Vergara, Santiago
2013-01-01
Infection is one of the most serious complications after total knee arthroplasty (TKA). The current incidence of prosthetic knee infection is 1-3%, depending on the series. For treatment and control to be more cost effective, multidisciplinary groups made up of professionals from different specialities who can work together to eradicate these kinds of infections need to be assembled. About the microbiology, Staphylococcus aureus and coagulase-negative staphylococcus were among the most frequent microorganisms involved (74%). Anamnesis and clinical examination are of primary importance in order to determine whether the problem may point to a possible acute septic complication. The first diagnosis may then be supported by increased CRP and ESR levels. The surgical treatment for a chronic prosthetic knee infection has been perfectly defined and standardized, and consists in a two-stage implant revision process. In contrast, the treatment for acute prosthetic knee infection is currently under debate. Considering the different surgical techniques that already exist, surgical debridement with conservation of the prosthesis and polythene revision appears to be an attractive option for both surgeon and patient, as it is less aggressive than the two-stage revision process and has lower initial costs. The different results obtained from this technique, along with prognosis factors and conclusions to keep in mind when it is indicated for an acute prosthetic infection, whether post-operative or haematogenous, will be analysed by the authors. PMID:23919094
Effect of polydeoxyribonucleotide injection on pes anserine bursitis
Mun, Jong-Uk; Cho, Hyung R.; Bae, Sae M.; Park, Soo K.; Choi, Soo .l; Seo, Mi S.; Lim, Young S.; RN, Soo H. Woo; Kim, Young U.
2017-01-01
Abstract Rationale: Pes anserine (PA) bursitis is an inflammatory condition of the medial knee. The PA bursa becomes more painful when infected, damaged, or irritated. Although various treatment options have been attempted to treat PA bursitis, optimal treatments are still debated. This study aims to investigate the effect of polydeoxyribonucleotide (PDRN) injection on reducing pain and inflammation in a patient presenting with PA bursitis. Patient concerns: A 50-year-old female patient was admitted to our pain clinic with symptoms of tenderness and pain over the medial knee. Physical examination revealed the pain to be located over the proximal medial tibia at the insertion of the conjoined tendons of the PA. The knee had lost its range of movement and strength, and resisted knee flexion. Diagnoses: She was diagnosed as having PA bursitis. Interventions: Ultrasound guided PA bursa injection was carried out. Outcomes: Follow-up for the patient was more than eight months. She showed good improvement in PA bursitis without any complications. Lessons: This is the first successful report of successful PDRN injection for PA bursa. PMID:29069005
Qiu, Li; Jiang, Yong; Zhang, Lingyan; Wang, Lei; Luo, Yan
2012-12-01
To investigate the ablative effectiveness of microbubble-mediated ultrasonic cavitation for treating synovial pannus and to determine a potential mechanism using the antigen-induced arthritis model (AIA). Ultrasonic ablation was performed on the knee joints of AIA rabbits using optimal ultrasonic ablative parameters. Rabbits with antigen-induced arthritis were randomly assigned to 4 groups: (1) the ultrasound (US) + microbubble group; (2) the US only group; (3) the microbubble only group, and (4) the control group. At 1 h and 14 days after the first ablation, contrast-enhanced ultrasonography (CEUS) monitoring and pathology synovitis score were used to evaluate the therapeutic effects. Synovial necrosis and microvascular changes were also measured. After the ablation treatment, the thickness of synovium and parameters of time intensity curve including derived peak intensity and area under curve were measured using CEUS, and the pathology synovitis score in the ultrasound + microbubble group was significantly lower than that found in the remaining groups. No damage was observed in the surrounding normal tissues. The mechanism underlying the ultrasonic ablation was related to microthrombosis and microvascular rupture that resulted in synovial necrosis. The results suggest that microbubble-mediated ultrasonic cavitation should be applied as a non-invasive strategy for the treatment of synovial pannus in arthritis under optimal conditions.
Arthrodesis of the knee using a custom-made intramedullary coupled device.
White, S P; Porteous, A J; Newman, J H; Mintowt-Czyz, W; Barr, V
2003-01-01
Nine patients underwent arthrodesis of the knee using customised coupled nail (the Mayday arthrodesis nail), five after infected arthroplasty, one following failed arthrodesis, one for intractable anterior knee pain, one for Charcot instability and one after trauma. Comparison was made with 17 arthrodeses, eight undertaken using external fixation, four with dual compression plates, and five with long Kütntscher nails. Union was achieved in all patients (100%) at a mean time of ten months using the customised implant. There were no complications despite early weight-bearing. No further procedures were required. This contrasted with a rate of union of 53% and a complication rate of 76% with alternative techniques. Of this second group, 76% required a further operative procedure. We compared the Mayday arthrodesis nail with other techniques of arthrodesis of the knee. The differences in the need for further surgery and occurrence of complications were statistically significant (p < 0.001), and differences in the rate of nonunion and inpatient stay of less than three weeks were also significant (p < 0.05) using Fisher's exact test. We conclude that a customised coupled intramedullary nail can give excellent stability allowing early weight-bearing, and results in a high rate of union with minimal postoperative complications.
Meldrum, Sarah; Savarimuthu, Bastin Tr; Licorish, Sherlock; Tahir, Amjed; Bosu, Michael; Jayakaran, Prasath
2017-01-01
There is little research that characterises knee pain related information disseminated via social media. However, variances in the content and quality of such sources could compromise optimal patient care. This study explored the nature of the comments on YouTube videos related to non-specific knee pain, to determine their helpfulness to the users. A systematic search identified 900 videos related to knee pain on the YouTube database. A total of 3537 comments from 58 videos were included in the study. A categorisation scheme was developed and 1000 randomly selected comments were analysed according to this scheme. The most common category was the users providing personal information or describing a personal situation (19%), followed by appreciation or acknowledgement of others' inputs (17%) and asking questions (15%). Of the questions, 33% were related to seeking help in relation to a specific situation. Over 10% of the comments contained negativity or disagreement; while 4.4% of comments reported they intended to pursue an action, based on the information presented in the video and/or from user comments. It was observed that individuals commenting on YouTube videos on knee pain were most often soliciting advice and information specific to their condition. The analysis of comments from the most commented videos using a keyword-based search approach suggests that the YouTube videos can be used for disseminating general advice on knee pain.
Meldrum, Sarah; Savarimuthu, Bastin TR; Licorish, Sherlock; Tahir, Amjed; Bosu, Michael; Jayakaran, Prasath
2017-01-01
Objective There is little research that characterises knee pain related information disseminated via social media. However, variances in the content and quality of such sources could compromise optimal patient care. This study explored the nature of the comments on YouTube videos related to non-specific knee pain, to determine their helpfulness to the users. Methods A systematic search identified 900 videos related to knee pain on the YouTube database. A total of 3537 comments from 58 videos were included in the study. A categorisation scheme was developed and 1000 randomly selected comments were analysed according to this scheme. Results The most common category was the users providing personal information or describing a personal situation (19%), followed by appreciation or acknowledgement of others’ inputs (17%) and asking questions (15%). Of the questions, 33% were related to seeking help in relation to a specific situation. Over 10% of the comments contained negativity or disagreement; while 4.4% of comments reported they intended to pursue an action, based on the information presented in the video and/or from user comments. Conclusion It was observed that individuals commenting on YouTube videos on knee pain were most often soliciting advice and information specific to their condition. The analysis of comments from the most commented videos using a keyword-based search approach suggests that the YouTube videos can be used for disseminating general advice on knee pain. PMID:29942583
Change in knee contact force with simulated change in body weight.
Knarr, Brian A; Higginson, Jill S; Zeni, Joseph A
2016-02-01
The relationship between obesity, weight gain and progression of knee osteoarthritis is well supported, suggesting that excessive joint loading may be a mechanism responsible for cartilage deterioration. Examining the influence of weight gain on joint compressive forces is difficult, as both muscles and ground reaction forces can have a significant impact on the forces experienced during gait. While previous studies have examined the relationship between body weight and knee forces, these studies have used models that were not validated using experimental data. Therefore, the objective of this study was to evaluate the relationship between changes in body weight and changes in knee joint contact forces for an individual's gait pattern using musculoskeletal modeling that is validated against known internal compressive forces. Optimal weighting constants were determined for three subjects to generate valid predictions of knee contact forces (KCFs) using in vivo data collection with instrumented total knee arthroplasty. A total of five simulations per walking trial were generated for each subject, from 80% to 120% body weight in 10% increments, resulting in 50 total simulations. The change in peak KCF with respect to body weight was found to be constant and subject-specific, predominantly determined by the peak force during the baseline condition at 100% body weight. This relationship may be further altered by any change in kinematics or body mass distribution that may occur as a result of a change in body weight or exercise program.
Estimation of Electrically-Evoked Knee Torque from Mechanomyography Using Support Vector Regression.
Ibitoye, Morufu Olusola; Hamzaid, Nur Azah; Abdul Wahab, Ahmad Khairi; Hasnan, Nazirah; Olatunji, Sunday Olusanya; Davis, Glen M
2016-07-19
The difficulty of real-time muscle force or joint torque estimation during neuromuscular electrical stimulation (NMES) in physical therapy and exercise science has motivated recent research interest in torque estimation from other muscle characteristics. This study investigated the accuracy of a computational intelligence technique for estimating NMES-evoked knee extension torque based on the Mechanomyographic signals (MMG) of contracting muscles that were recorded from eight healthy males. Simulation of the knee torque was modelled via Support Vector Regression (SVR) due to its good generalization ability in related fields. Inputs to the proposed model were MMG amplitude characteristics, the level of electrical stimulation or contraction intensity, and knee angle. Gaussian kernel function, as well as its optimal parameters were identified with the best performance measure and were applied as the SVR kernel function to build an effective knee torque estimation model. To train and test the model, the data were partitioned into training (70%) and testing (30%) subsets, respectively. The SVR estimation accuracy, based on the coefficient of determination (R²) between the actual and the estimated torque values was up to 94% and 89% during the training and testing cases, with root mean square errors (RMSE) of 9.48 and 12.95, respectively. The knee torque estimations obtained using SVR modelling agreed well with the experimental data from an isokinetic dynamometer. These findings support the realization of a closed-loop NMES system for functional tasks using MMG as the feedback signal source and an SVR algorithm for joint torque estimation.
Kwon, Suncheol; Stanley, Christopher J.; Kim, Jung; Kim, Jonghyun; Damiano, Diane L.
2013-01-01
Individuals with cerebral palsy have neurological deficits that may interfere with motor function and lead to abnormal walking patterns. It is important to know the joint moment generated by the patient’s muscles during walking in order to assist the suboptimal gait patterns. In this paper, we describe a practical strategy for estimating the internal moment of a knee joint from surface electromyography (sEMG) and knee joint angle measurements. This strategy requires only isokinetic knee flexion and extension tests to obtain a relationship between the sEMG and the knee internal moment, and it does not necessitate comprehensive laboratory calibration, which typically requires a 3-D motion capture system and ground reaction force plates. Four estimation models were considered based on different assumptions about the functions of the relevant muscles during the isokinetic tests and the stance phase of walking. The performance of the four models was evaluated by comparing the estimated moments with the gold standard internal moment calculated from inverse dynamics. The results indicate that an optimal estimation model can be chosen based on the degree of cocontraction. The estimation error of the chosen model is acceptable (normalized root-mean-squared error: 0.15–0.29, R: 0.71–0.93) compared to previous studies (Doorenbosch and Harlaar, 2003; Doorenbosch and Harlaar, 2004; Doorenbosch, Joosten, and Harlaar, 2005), and this strategy provides a simple and effective solution for estimating knee joint moment from sEMG. PMID:22410952
Gandhamal, Akash; Talbar, Sanjay; Gajre, Suhas; Razak, Ruslan; Hani, Ahmad Fadzil M; Kumar, Dileep
2017-09-01
Knee osteoarthritis (OA) progression can be monitored by measuring changes in the subchondral bone structure such as area and shape from MR images as an imaging biomarker. However, measurements of these minute changes are highly dependent on the accurate segmentation of bone tissue from MR images and it is challenging task due to the complex tissue structure and inadequate image contrast/brightness. In this paper, a fully automated method for segmenting subchondral bone from knee MR images is proposed. Here, the contrast of knee MR images is enhanced using a gray-level S-curve transformation followed by automatic seed point detection using a three-dimensional multi-edge overlapping technique. Successively, bone regions are initially extracted using distance-regularized level-set evolution followed by identification and correction of leakages along the bone boundary regions using a boundary displacement technique. The performance of the developed technique is evaluated against ground truths by measuring sensitivity, specificity, dice similarity coefficient (DSC), average surface distance (AvgD) and root mean square surface distance (RMSD). An average sensitivity (91.14%), specificity (99.12%) and DSC (90.28%) with 95% confidence interval (CI) in the range 89.74-92.54%, 98.93-99.31% and 88.68-91.88% respectively is achieved for the femur bone segmentation in 8 datasets. For tibia bone, average sensitivity (90.69%), specificity (99.65%) and DSC (91.35%) with 95% CI in the range 88.59-92.79%, 99.50-99.80% and 88.68-91.88% respectively is achieved. AvgD and RMSD values for femur are 1.43 ± 0.23 (mm) and 2.10 ± 0.35 (mm) respectively while for tibia, the values are 0.95 ± 0.28 (mm) and 1.30 ± 0.42 (mm) respectively that demonstrates acceptable error between proposed method and ground truths. In conclusion, results obtained in this work demonstrate substantially significant performance with consistency and robustness that led the proposed method to be applicable for large scale and longitudinal knee OA studies in clinical settings. Copyright © 2017 Elsevier Ltd. All rights reserved.
Effect of resistance training on muscle use during exercise
NASA Technical Reports Server (NTRS)
Ploutz, Lori L.; Tesch, Per A.; Biro, Ronald L.; Dudley, Gary A.
1994-01-01
This study examined the effect of resistance training on exercise-induced contrast shift in magnetic resonance (MR) images. It was hypothesized that a given load could be lifted after training with less muscle showing contrast shift, thereby suggesting less muscle was used to perform the exercise. Nine males trained the left quadriceps femoris (QF) muscle 2 days/wk for 9 wk using 3-6 sets of 12 knee extensions each day. The right QF served as a control. Exercise-induced contrast shifts in MR images evoked by each of three bouts of exercise (5 sets of 10 knee extensions with a load equal to 50, 75, and 100% of the maximum pretraining load that could be lifted for 5 sets of 10 repetitions) were quantified pre- and posttraining. MR image contrast shift was quantified by determining QF cross-sectional area (CSA) showing increased spin-spin relaxation time. One repetition maximum increased 14% in the left trained QF and 7% in the right untrained QF. Left QF CSA increased 5%, with no change in right QSF CSA. Left QF CSA showing contrast shift was less after each bout of the exercise test posttraining. This was also true, to a lesser extent, for the right QF at the higher two loads. The results suggest that short-term resistance training reduces MR image contrast shift evoked by a given effort, thereby reflecting the use of less muscle to lift the load. Because this response was evident in both trained and contralateral untrained muscle, neural factors are suggested to be responsible. The consequence of this adaptation could be to increase 'stress' per unit area of active muscle during the course of training and thereby evoke hypertrophy.
Arun, S; Kanagaraj, S
2015-10-01
Trans femoral amputation is one of the most uncomfortable surgeries in patient׳s life, where the prosthesis consisting of a socket, knee joint, pylon and foot is used to do the walking activities. The artificial prosthetic knee joint imitates the functions of human knee to achieve the flexion-extension for the above knee amputee. The objective of present work is to develop a light weight composite material for the knee joint to reduce the metabolic cost of an amputee. Hence, an attempt was made to study the mechanical properties of multi walled carbon nanotubes (MWCNT) reinforced Poly (methyl methacrylate) (PMMA) prepared through melt mixing technique and optimize the concentration of reinforcement. The PMMA nanocomposites were prepared by reinforcing 0, 0.1, 0.2, 0.25, 0.3 and 0.4 wt% of MWCNT using injection moulding machine via twin screw extruder. It is observed that the tensile and flexural strength of PMMA, which were studied as per ASTM D638 and D790, respectively, were increased by 32.9% and 26.3% till 0.25 wt% reinforcement of MWCNT. The experimental results of strength and modulus were compared with theoretical prediction, where a good correlation was noted. It is concluded that the mechanical properties of PMMA were found to be increased to maximum at 0.25 wt% reinforcement of MWCNT, where the Pukanszky model and modified Halpin-Tsai model are suggested to predict the strength and modulus, respectively, of the PMMA/MWCNT composite, which can be opted as a suitable materiel for the development of polycentric knee joint. Copyright © 2015 Elsevier Ltd. All rights reserved.
Deasy, Margaret; Leahy, Edmund; Semciw, Adam Ivan
2016-08-01
Study Design Systematic review with meta-analysis. Background A complete understanding of impairments associated with knee osteoarthritis would optimize exercise interventions for people with knee osteoarthritis. Our current understanding of hip strength deficits in this population is based on studies with conflicting findings and small samples. There is a need to systematically review and pool current evidence. Objectives To determine whether hip strength deficits exist in people with symptomatic knee osteoarthritis. Methods Electronic databases (MEDLINE, CINAHL, Embase, the Cochrane Library, and PsycINFO) were searched through February 2016. Studies comparing hip strength in people diagnosed with symptomatic knee osteoarthritis to healthy control participants were included in the review. A meta-analysis with random effects was applied to relevant data from included studies and a modified Grading of Recommendations Assessment, Development and Evaluation approach was used to evaluate the quality of evidence for each pooled analysis. Results Five studies were included in the review. Meta-analysis revealed moderate-quality evidence of weaker isometric and isokinetic hip abduction strength in people with knee osteoarthritis (moderate difference: 7% to 24% weaker) and very low-quality evidence of no difference in isometric hip adduction strength. There was very low- to moderate-quality evidence of weaker isokinetic hip strength in the remaining planes of motion (moderate to large differences: 14% to 55% weaker). Conclusion Significant hip strength deficits exist in people with knee osteoarthritis. Hip strength assessment should be considered in clinical practice and may assist with directing targeted management strategies. Level of Evidence Symptom prevalence, level 1a-. J Orthop Sports PhysTher 2016;46(8):629-639. Epub3 Jul 2016. doi:10.2519/jospt.2016.6618.
Perruccio, Anthony V; Gandhi, Rajiv; Rampersaud, Y Raja
2013-03-07
Health status is an important predictor of patient outcomes. Consequently, identifying patient predictors of health status is essential. In musculoskeletal orthopaedic care, the majority of work examining the association between patient characteristics and health status has been undertaken among hip/knee cohorts. We investigate these associations comparing findings across four musculoskeletal cohorts (hip/knee; foot/ankle; neck/back; elbow/shoulder). Patients seeking elective musculoskeletal orthopaedic care were recruited prior to consultation. Questionnaires captured health domain status (bodily pain, physical functioning, and mental and general health) and covariates: demographics; socioeconomic characteristics; and comorbidity. Scores were compared across cohorts. Two path regression analyses were undertaken. First, domain scores were simultaneously examined as dependent variables in the overall sample. Subsequently, the model was assessed stratified by cohort. 1,948 patients: 454 neck/back, 767 hip/knee, 378 shoulder/elbow, 349 foot/ankle. From stratified analyses, significant variability in covariate effects was observed. Worse bodily pain scores were associated with increasing age and female sex among hip/knee, low income among foot/ankle, and overweight/obese for foot/ankle and hip/knee. Worse mental health scores were associated with low income across cohorts except elbow/shoulder, low education within neck/back, and compared to Whites, Blacks had significantly worse scores among foot/ankle, better scores among hip/knee. Worse general health scores were observed for Asians among hip/knee, Blacks among foot/ankle, and South-Asians among elbow/shoulder and neck/back. The substantial heterogeneity across musculoskeletal cohorts suggests that patient- and cohort-specific approaches to patient counsel and care may be more effective for achieving optimal health and outcomes.
Wahal, Naman; Gaba, Sahil; Malhotra, Rajesh; Kumar, Vijay; Pegg, Elise C; Pandit, Hemant
2018-02-01
A small proportion of patients with mobile unicompartmental knee arthroplasty (UKA) report poor functional outcomes in spite of optimal component alignment on postoperative radiographs. The purpose of this study is to assess whether there is a correlation between functional outcome and knee kinematics. From a cohort of consecutive cases of 150 Oxford medial UKA, patients with fair/poor functional outcome at 1-year postsurgery (Oxford Knee Score [OKS] < 34, n = 15) were identified and matched for age, gender, preoperative clinical scores, and follow-up period with a cohort of patients with good/excellent outcome (OKS ≥ 34, n = 15). In vivo kinematic assessment was performed using step-up and deep knee bend exercises under fluoroscopic imaging. The fluoroscopic videos were analyzed using MATLAB software to measure the variation in time taken to complete the exercises, patellar tendon angle, and bearing position with knee flexion angle. Mean OKS in the fair/poor group was 29.9 and the mean OKS in the good/excellent group was 41.1. The tibial slope, time taken to complete the exercises, and patellar tendon angle trend over the flexion range were similar in both the groups; however, bearing position and the extent of bearing excursion differed significantly. The total bearing excursion in the OKS < 34 group was significantly smaller than the OKS ≥ 34 group (35%). Furthermore, on average, the bearing was positioned 1.7 mm more posterior on the tibia in the OKS < 34 group. This study provides evidence that abnormal knee kinematics, in particular bearing excursion and positioning, are associated with worse functional outcomes after mobile UKA. Copyright © 2017 Elsevier Inc. All rights reserved.
Smith, Colin R; Vignos, Michael F; Lenhart, Rachel L; Kaiser, Jarred; Thelen, Darryl G
2016-02-01
The study objective was to investigate the influence of coronal plane alignment and ligament properties on total knee replacement (TKR) contact loads during walking. We created a subject-specific knee model of an 83-year-old male who had an instrumented TKR. The knee model was incorporated into a lower extremity musculoskeletal model and included deformable contact, ligamentous structures, and six degrees-of-freedom (DOF) tibiofemoral and patellofemoral joints. A novel numerical optimization technique was used to simultaneously predict muscle forces, secondary knee kinematics, ligament forces, and joint contact pressures from standard gait analysis data collected on the subject. The nominal knee model predictions of medial, lateral, and total contact forces during gait agreed well with TKR measures, with root-mean-square (rms) errors of 0.23, 0.22, and 0.33 body weight (BW), respectively. Coronal plane component alignment did not affect total knee contact loads, but did alter the medial-lateral load distribution, with 4 deg varus and 4 deg valgus rotations in component alignment inducing +17% and -23% changes in the first peak medial tibiofemoral contact forces, respectively. A Monte Carlo analysis showed that uncertainties in ligament stiffness and reference strains induce ±0.2 BW uncertainty in tibiofemoral force estimates over the gait cycle. Ligament properties had substantial influence on the TKR load distributions, with the medial collateral ligament and iliotibial band (ITB) properties having the largest effects on medial and lateral compartment loading, respectively. The computational framework provides a viable approach for virtually designing TKR components, considering parametric uncertainty and predicting the effects of joint alignment and soft tissue balancing procedures on TKR function during movement.
Smith, Colin R.; Vignos, Michael F.; Lenhart, Rachel L.; Kaiser, Jarred; Thelen, Darryl G.
2016-01-01
The study objective was to investigate the influence of coronal plane alignment and ligament properties on total knee replacement (TKR) contact loads during walking. We created a subject-specific knee model of an 83-year-old male who had an instrumented TKR. The knee model was incorporated into a lower extremity musculoskeletal model and included deformable contact, ligamentous structures, and six degrees-of-freedom (DOF) tibiofemoral and patellofemoral joints. A novel numerical optimization technique was used to simultaneously predict muscle forces, secondary knee kinematics, ligament forces, and joint contact pressures from standard gait analysis data collected on the subject. The nominal knee model predictions of medial, lateral, and total contact forces during gait agreed well with TKR measures, with root-mean-square (rms) errors of 0.23, 0.22, and 0.33 body weight (BW), respectively. Coronal plane component alignment did not affect total knee contact loads, but did alter the medial–lateral load distribution, with 4 deg varus and 4 deg valgus rotations in component alignment inducing +17% and −23% changes in the first peak medial tibiofemoral contact forces, respectively. A Monte Carlo analysis showed that uncertainties in ligament stiffness and reference strains induce ±0.2 BW uncertainty in tibiofemoral force estimates over the gait cycle. Ligament properties had substantial influence on the TKR load distributions, with the medial collateral ligament and iliotibial band (ITB) properties having the largest effects on medial and lateral compartment loading, respectively. The computational framework provides a viable approach for virtually designing TKR components, considering parametric uncertainty and predicting the effects of joint alignment and soft tissue balancing procedures on TKR function during movement. PMID:26769446
Street, Richard L.; Cox, Vanessa; Kallen, Michael A.; Suarez-Almazor, Maria E.
2012-01-01
Objective This study tested a pathway whereby acupuncturists’ communication of optimism for treatment effectiveness would enhance patients’ satisfaction during treatment, which in turn would contribute to better pain and function outcomes for patients with osteoarthritis of the knee. Methods Secondary analysis from a 2 arm (real vs. sham acupuncture, high vs. neutral expectations) RCT. 311 patients with knee osteoarthritis received acupuncture over 10–12 sessions. Coders rated the degree to which acupuncturists communicated optimism for the treatment’s effectiveness. Satisfaction with acupuncture was assessed 4 weeks into treatment. Pain and function were assessed 6 weeks following treatment. Results Patients experiencing better outcomes were more satisfied with acupuncture during treatment, were younger, and had better baseline pain and function scores. Satisfaction during treatment was greater when patients interacted with more optimistic clinicians and had higher pretreatment expectations for acupuncture efficacy. Conclusion Acupuncturists’ communication of optimism about treatment effectiveness contributed to pain and function outcomes indirectly through its effect on satisfaction during treatment. Future research should model pathways through which clinician-patient communication affects mediating variables that in turn lead to improved health outcomes. Practical Implications While clinicians should not mislead patients, communicating hope and optimism for treatment effectiveness has therapeutic value for patients. PMID:22857778
Kim, Wangdo; Espanha, Margarida M.; Veloso, António P.; Araújo, Duarte; João, Filipa; Carrão, Luis; Kohles, Sean S.
2013-01-01
Traditional locomotion studies emphasize an optimization of the desired movement trajectories while ignoring sensory feedback. We propose an information based theory that locomotion is neither triggered nor commanded but controlled. The basis for this control is the information derived from perceiving oneself in the world. Control therefore lies in the human-environment system. In order to test this hypothesis, we derived a mathematical foundation characterizing the energy that is required to perform a rotational twist, with small amplitude, of the instantaneous axes of the knee (IAK). We have found that the joint’s perception of the ground reaction force may be replaced by the co-perception of muscle activation with appropriate intensities. This approach generated an accurate comparison with known joint forces and appears appropriate in so far as predicting the effect on the knee when it is free to twist about the IAK. PMID:24932433
Posterior cruciate ligament: anatomy, biomechanics, and outcomes.
Voos, James E; Mauro, Craig S; Wente, Todd; Warren, Russell F; Wickiewicz, Thomas L
2012-01-01
The optimal treatment of posterior cruciate ligament ruptures remains controversial despite numerous recent basic science advances on the topic. The current literature on the anatomy, biomechanics, and clinical outcomes of posterior cruciate ligament reconstruction is reviewed. Recent studies have quantified the anatomic location and biomechanical contribution of each of the 2 posterior cruciate ligament bundles on tunnel placement and knee kinematics during reconstruction. Additional laboratory and cadaveric studies have suggested double-bundle reconstructions of the posterior cruciate ligament may better restore normal knee kinematics than single-bundle reconstructions although clinical outcomes have not revealed such a difference. Tibial inlay posterior cruciate ligament reconstructions (either open or arthroscopic) are preferred by many authors to avoid the "killer turn" and graft laxity with cyclic loading. Posterior cruciate ligament reconstruction improves subjective patient outcomes and return to sport although stability and knee kinematics may not return to normal.
Performance of local optimization in single-plane fluoroscopic analysis for total knee arthroplasty.
Prins, A H; Kaptein, B L; Stoel, B C; Lahaye, D J P; Valstar, E R
2015-11-05
Fluoroscopy-derived joint kinematics plays an important role in the evaluation of knee prostheses. Fluoroscopic analysis requires estimation of the 3D prosthesis pose from its 2D silhouette in the fluoroscopic image, by optimizing a dissimilarity measure. Currently, extensive user-interaction is needed, which makes analysis labor-intensive and operator-dependent. The aim of this study was to review five optimization methods for 3D pose estimation and to assess their performance in finding the correct solution. Two derivative-free optimizers (DHSAnn and IIPM) and three gradient-based optimizers (LevMar, DoNLP2 and IpOpt) were evaluated. For the latter three optimizers two different implementations were evaluated: one with a numerically approximated gradient and one with an analytically derived gradient for computational efficiency. On phantom data, all methods were able to find the 3D pose within 1mm and 1° in more than 85% of cases. IpOpt had the highest success-rate: 97%. On clinical data, the success rates were higher than 85% for the in-plane positions, but not for the rotations. IpOpt was the most expensive method and the application of an analytically derived gradients accelerated the gradient-based methods by a factor 3-4 without any differences in success rate. In conclusion, 85% of the frames can be analyzed automatically in clinical data and only 15% of the frames require manual supervision. The optimal success-rate on phantom data (97% with IpOpt) on phantom data indicates that even less supervision may become feasible. Copyright © 2015 Elsevier Ltd. All rights reserved.
Fukuda, Thiago Yukio; Melo, William Pagotti; Zaffalon, Bruno Marcos; Rossetto, Flavio Marcondes; Magalhães, Eduardo; Bryk, Flavio Fernandes; Martin, Robroy L
2012-10-01
Randomized controlled trial. To determine if adding hip-strengthening exercises to a conventional knee exercise program produces better long-term outcomes than conventional knee exercises alone in women with patellofemoral pain syndrome (PFPS). Recent studies have shown that a hip-strengthening program reduces pain and improves function in individuals with PFPS. However, there are no clinical trials evaluating long-term outcomes of this type of program compared to conventional knee-strengthening and -stretching exercises. Fifty-four sedentary women between 20 and 40 years of age, with a diagnosis of unilateral PFPS, were randomly assigned knee exercise (KE) or knee and hip exercise (KHE). The women in the KE group (n = 26; mean age, 23 years) performed a 4-week conventional knee-stretching and -strengthening program. The women in the KHE group (n = 28; mean age, 22 years) performed the same exercises as those in the KE group, as well as strengthening exercises for the hip abductors, lateral rotators, and extensors. An 11-point numeric pain rating scale, the Lower Extremity Functional Scale, the Anterior Knee Pain Scale, and a single-hop test were used as outcome measures at baseline (pretreatment) and 3, 6, and 12 months posttreatment. At baseline, demographic, pain, and functional assessment data were similar between groups. Those in the KHE group had a higher level of function and less pain at 3, 6, and 12 months compared to baseline (P<.05). In contrast, the KE group had reduced pain only at the 3- and 6-month follow-ups (P<.05), without any changes in Lower Extremity Functional Scale, Anterior Knee Pain Scale, or hop testing (P>.05) through the course of the study. Compared to the KE group, the KHE group had less pain and better function at 3, 6, and 12 months posttreatment (P<.05). For the Lower Extremity Functional Scale, the between-group difference in change scores from baseline at 3, 6, and 12 months posttreatment favored the KHE group by 22.0, 22.0, and 20.8 points, respectively. Knee-stretching and -strengthening exercises supplemented by hip posterolateral musculature-strengthening exercises were more effective than knee exercises alone in improving long-term function and reducing pain in sedentary women with PFPS.
An instrumented spatial linkage for measuring knee joint kinematics.
Rosvold, Joshua M; Atarod, Mohammad; Frank, Cyril B; Shrive, Nigel G
2016-01-01
In this study, the design and development of a highly accurate instrumented spatial linkage (ISL) for kinematic analysis of the ovine stifle joint is described. The ovine knee is a promising biomechanical model of the human knee joint. The ISL consists of six digital rotational encoders providing six degrees of freedom (6-DOF) to its motion. The ISL makes use of the complete and parametrically continuous (CPC) kinematic modeling method to describe the kinematic relationship between encoder readings and the relative positions and orientation of its two ends. The CPC method is useful when calibrating the ISL, because a small change in parameters corresponds to a small change in calculated positions and orientations and thus a smaller optimization error, compared to other kinematic models. The ISL is attached rigidly to the femur and the tibia for motion capture, and the CPC kinematic model is then employed to transform the angle sensor readings to relative motion of the two ends of the linkage, and thereby, the stifle joint motion. The positional accuracy for ISL after calibration and optimization was 0.3±0.2mm (mean +/- standard deviation). The ISL was also evaluated dynamically to ensure that accurate results were maintained, and achieved an accuracy of 0.1mm. Compared to the traditional motion capture methods, this system provides increased accuracy, reduced processing time, and ease of use. Future work will be on the application of the ISL to the ovine gait and determination of in vivo joint motions and tissue loads. Accurate measurement of knee joint kinematics is essential in understanding injury mechanisms and development of potential preventive or treatment strategies. Copyright © 2015 Elsevier B.V. All rights reserved.
Kumar, Neelesh
2014-10-01
Finite element analysis has been universally employed for the stress and strain analysis in lower extremity prosthetics. The socket adapter was the principal subject of interest due to its importance in deciding the knee motion range. This article focused on the static and dynamic stress analysis of the designed hybrid adapter developed by the authors. A standard mechanical design validation approach using von Mises was followed. Four materials were considered for the analysis, namely, carbon fiber, oil-filled nylon, Al-6061, and mild steel. The paper analyses the static and dynamic stress on designed hybrid adapter which incorporates features of conventional male and female socket adapters. The finite element analysis was carried out for possible different angles of knee flexion simulating static and dynamic gait situation. Research was carried out on available design of socket adapter. Mechanical design of hybrid adapter was conceptualized and a CAD model was generated using Inventor modelling software. Static and dynamic stress analysis was carried out on different materials for optimization. The finite element analysis was carried out on the software Autodesk Inventor Professional Ver. 2011. The peak value of von Mises stress occurred in the neck region of the adapter and in the lower face region at rod eye-adapter junction in static and dynamic analyses, respectively. Oil-filled nylon was found to be the best material among the four with respect to strength, weight, and cost. Research investigations on newer materials for development of improved prosthesis will immensely benefit the amputees. The study analyze the static and dynamic stress on the knee joint adapter to provide better material used for hybrid design of adapter. © The International Society for Prosthetics and Orthotics 2013.
Naghibi Beidokhti, Hamid; Janssen, Dennis; van de Groes, Sebastiaan; Hazrati, Javad; Van den Boogaard, Ton; Verdonschot, Nico
2017-12-08
In finite element (FE) models knee ligaments can represented either by a group of one-dimensional springs, or by three-dimensional continuum elements based on segmentations. Continuum models closer approximate the anatomy, and facilitate ligament wrapping, while spring models are computationally less expensive. The mechanical properties of ligaments can be based on literature, or adjusted specifically for the subject. In the current study we investigated the effect of ligament modelling strategy on the predictive capability of FE models of the human knee joint. The effect of literature-based versus specimen-specific optimized material parameters was evaluated. Experiments were performed on three human cadaver knees, which were modelled in FE models with ligaments represented either using springs, or using continuum representations. In spring representation collateral ligaments were each modelled with three and cruciate ligaments with two single-element bundles. Stiffness parameters and pre-strains were optimized based on laxity tests for both approaches. Validation experiments were conducted to evaluate the outcomes of the FE models. Models (both spring and continuum) with subject-specific properties improved the predicted kinematics and contact outcome parameters. Models incorporating literature-based parameters, and particularly the spring models (with the representations implemented in this study), led to relatively high errors in kinematics and contact pressures. Using a continuum modelling approach resulted in more accurate contact outcome variables than the spring representation with two (cruciate ligaments) and three (collateral ligaments) single-element-bundle representations. However, when the prediction of joint kinematics is of main interest, spring ligament models provide a faster option with acceptable outcome. Copyright © 2017 Elsevier Ltd. All rights reserved.
The Stem-Cell Market for the Treatment of Knee Osteoarthritis: A Patient Perspective.
Piuzzi, Nicolas S; Ng, Mitchell; Chughtai, Morad; Khlopas, Anton; Ng, Kenneth; Mont, Michael A; Muschler, George F
2018-07-01
The use of stem-cell therapies for the treatment of various musculoskeletal conditions, especially knee osteoarthritis (OA), is rapidly expanding, despite only low-level evidence to support its use. Centers offering these therapies are often marketing and charging patients out-of-pocket costs for such services. Therefore, the purpose of this study was to determine the current marketed: (1) prices and (2) clinical efficacy of stem-cell therapies for knee OA. This was a prospective cross-sectional study which queried 317 U.S. centers that offered direct-to-consumer stem-cell therapies for musculoskeletal conditions. A total of 273 of 317 centers were successfully contacted via phone or e-mail, using a simulated 57-year-old male patient with knee OA. Scripted questions were asked by the simulated patient to determine the marketed prices and clinical efficacy. Centers generally reported the proportion of patients who had "good results" or "symptomatic improvement." The mean price of a unilateral (same-day) stem-cell knee injection was $5,156 with a standard deviation of $2,446 (95% confidence interval [CI]: $4,550-5,762, n = 65). The mean proportion of claimed clinical efficacy was 82% with a standard deviation of 9.6% (95% CI: 79.0-85.5%, n = 36). Most American stem-cell centers offer therapies for knee OA. The cost of these therapies averages about $5,000 per injection, and centers claim that 80% of the patients had "good results" or "symptomatic improvement," denoting a gap between what is documented in the published literature and the marketing claims. These findings offer both patients and physicians insight into the current stem-cell market for knee OA. We hope that with this information, providers can more optimally make patients aware of discrepancies between what is being marketed versus the current evidence-based landscape of these therapies for knee OA. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Lavallé, F; Pascal-Mousselard, H; Rouvillain, J L; Ribeyre, D; Delattre, O; Catonné, Y
2004-10-01
The aim of this radiological study was to evaluate the use of a biphasic ceramic wedge combined with plate fixation with locked adjustable screws for open wedge tibial osteotomy. Twenty-six consecutive patients (27 knees) underwent surgery between December 1999 and March 2002 to establish a normal lower-limb axis. The series included 6 women and 20 men, mean age 50 years (16 right knees and 11 left knees). Partial weight-bearing with crutches was allowed on day 1. A standard radiological assessment was performed on day 1, 90, and 360 (plain AP and lateral stance films of the knee). A pangonogram was performed before surgery and at day 360. Presence of a lateral metaphyseal space, development of peripheral cortical bridges, and osteointegration of the bone substitute-bone interface were evaluated used to assess bone healing. The medial tibial angle between the line tangent to the tibial plateau and the anatomic axis of the tibia (beta) was evaluated to assess preservation of postoperative correction. The HKA angle was determined. Three patients were lost to follow-up and 23 patients (24 knees) were retained for analysis. At last follow-up, presence of peripheral cortical bridges and complete filling of the lateral metaphyseal space demonstrated bone healing in all patients. Good quality osteointegration was achieved since 21 knees did not present an interface between the bone substitute and native bone (homogeneous transition zone). The beta angle was unchanged for 23 knees. A normal axis was observed in patients (16 knees) postoperatively. Use of a biphasic ceramic wedge in combination with plate fixation with locked adjustable screws is a reliable option for open wedge tibial osteotomy. The bone substitute fills the gap well. Tolerance and integration are optimal. Bone healing is achieved. Plate fixation with protected weight bearing appears to be a solid assembly, maintaining these corrections.
Zhang, Yu; Liu, Jun; Tian, Meng-qiang; Cheng, Yu; Tian, Zheng-wei; Sun, Zhen-hui; Ma, Xin-long
2010-05-15
To determine the effect of the posterior condylar offset (PCO) on intra- and post-operative knee flexion after total knee arthroplasty (TKA) using a high-flex posterior-stabilized (PS) fixed-bearing prosthesis and to discuss it's importance in femoral prosthesis design. The clinical and radiographic materials of 100 consecutive patients (100 knees) were prospectively studied, including 50 men and 50 women, who had undergone primary NexGen LPS-Flex TKAs for end-stage osteoarthritis. All operations were performed by a single surgeon using the same operative technique between March 2005 and October 2006. Pearson's regression analysis was used to assess the relationship between the difference in the pre- and post-operative PCO on true lateral radiographs and the change in knee range of flexion (ROF) under non-weight-bearing conditions. The decrease of the corrected PCO was (3.4 ± 3.3) mm compared with the preoperative value, the restoration of PCO was better in male than female [female (-5.4 ± 3.1) mm vs. male (-1.5 ± 2.0) mm, P < 0.05]. The difference in the corrected PCO after PS TKA demonstrated significantly correlated with the change in 2 years postoperative ROF in male and female, respectively (P < 0.05). While no statistically correlation was observed in the overall group (P > 0.05). Intraoperatively, the difference in the corrected PCO was significantly correlated with the change in ROF in male, female, and the overall group, respectively (P < 0.05). Restoration of PCO plays an important role in the optimization of knee flexion after high-flex PS TKA. Femoral components based on Caucasian anatomic characteristics could not match the native anatomy of distal femurs of Chinese population especially female Chinese. Rotated resection of distal femur with anterior referencing technique usually leads to a decreased PCO and therefore reduces maximal obtainable flexion. Sexual dimorphism in humans and anatomic variations in various ethnic groups should be seriously considered in total knee prosthesis design.
The Effect of Initial Knee Angle on Concentric-Only Squat Jump Performance.
Mitchell, Lachlan J; Argus, Christos K; Taylor, Kristie-Lee; Sheppard, Jeremy M; Chapman, Dale W
2017-06-01
There is uncertainty as to which knee angle during a squat jump (SJ) produces maximal jump performance. Importantly, understanding this information will aid in determining appropriate ratios for assessment and monitoring of the explosive characteristics of athletes. This study compared SJ performance across different knee angles-90º, 100º, 110º, 120º, 130º, and a self-selected depth-for jump height and other kinetic characteristics. For comparison between SJ and an unconstrained dynamic movement, participants also performed a countermovement jump from a self-selected depth. Thirteen participants (M age = 25.4 ± 3.5 years, M height = 1.8 ± 0.06 m, M weight = 79.8 ± 9.5 kg) were recruited and tested for their SJ performance. In the SJ, maximal jump height (35.4 ± 4.6 cm) was produced using a self-selected knee angle (98.7 ± 11.2°). Differences between 90°, 100°, and self-selected knee angles for jump height were trivial (ES ± 90% CL = 90°-100° 0.23 ± 0.12, 90°-SS -0.04 ± 0.12, 100°-SS -0.27 ± 0.20; 0.5-2.4 cm) and not statistically different. Differences between all other knee angles for jump height ranged from 3.8 ± 2.0 cm (mean ± 90% CL) to 16.6 ± 2.2 cm. A similar outcome to jump height was observed for velocity, force relative to body weight, and impulse for the assessed knee angles. For young physically active adult men, the use of a self-selected depth in the SJ results in optimal performance and has only a trivial difference to a constrained knee angle of either 90° or 100°.
Schelin, Lina; Tengman, Eva; Ryden, Patrik; Häger, Charlotte
2017-01-01
Clinical test batteries for evaluation of knee function after injury to the Anterior Cruciate Ligament (ACL) should be valid and feasible, while reliably capturing the outcome of rehabilitation. There is currently a lack of consensus as to which of the many available assessment tools for knee function that should be included. The present aim was to use a statistical approach to investigate the contribution of frequently used tests to avoid redundancy, and filter them down to a proposed comprehensive and yet feasible test battery for long-term evaluation after ACL injury. In total 48 outcome variables related to knee function, all potentially relevant for a long-term follow-up, were included from a cross-sectional study where 70 ACL-injured (17-28 years post injury) individuals were compared to 33 controls. Cluster analysis and logistic regression were used to group variables and identify an optimal test battery, from which a summarized estimator of knee function representing various functional aspects was derived. As expected, several variables were strongly correlated, and the variables also fell into logical clusters with higher within-correlation (max ρ = 0.61) than between clusters (max ρ = 0.19). An extracted test battery with just four variables assessing one-leg balance, isokinetic knee extension strength and hop performance (one-leg hop, side hop) were mathematically combined to an estimator of knee function, which acceptably classified ACL-injured individuals and controls. This estimator, derived from objective measures, correlated significantly with self-reported function, e.g. Lysholm score (ρ = 0.66; p<0.001). The proposed test battery, based on a solid statistical approach, includes assessments which are all clinically feasible, while also covering complementary aspects of knee function. Similar test batteries could be determined for earlier phases of ACL rehabilitation or to enable longitudinal monitoring. Such developments, established on a well-grounded consensus of measurements, would facilitate comparisons of studies and enable evidence-based rehabilitation.
Outcome of total knee replacement following explantation and cemented spacer therapy.
Ghanem, Mohamed; Zajonz, Dirk; Bollmann, Juliane; Geissler, Vanessa; Prietzel, Torsten; Moche, Michael; Roth, Andreas; Heyde, Christoph-E; Josten, Christoph
2016-01-01
Infection after total knee replacement (TKR) is one of the serious complications which must be pursued with a very effective therapeutic concept. In most cases this means revision arthroplasty, in which one-setting and two-setting procedures are distinguished. Healing of infection is the conditio sine qua non for re-implantation. This retrospective work presents an assessment of the success rate after a two-setting revision arthroplasty of the knee following periprosthetic infection. It further considers drawing conclusions concerning the optimal timing of re-implantation. A total of 34 patients have been enclosed in this study from September 2005 to December 2013. 35 re-implantations were carried out following explantation of total knee and implantation of cemented spacer. The patient's group comprised of 53% (18) males and 47% (16) females. The average age at re-implantation time was 72.2 years (ranging from 54 to 85 years). We particularly evaluated the microbial spectrum, the interval between explantation and re-implantation, the number of surgeries that were necessary prior to re-implantation as well as the postoperative course. We reported 31.4% (11) reinfections following re-implantation surgeries. The number of the reinfections declined with increasing time interval between explantation and re-implantation. Patients who developed reinfections were operated on (re-implantation) after an average of 4.47 months. Those patients with uncomplicated course were operated on (re-implantation) after an average of 6.79 months. Nevertheless, we noticed no essential differences in outcome with regard to the number of surgeries carried out prior to re-implantation. Mobile spacers proved better outcome than temporary arthrodesis with intramedullary fixation. No uniform strategy of treatment exists after peri-prosthetic infections. In particular, no optimal timing can be stated concerning re-implantation. Our data point out to the fact that a longer time interval between explantation and re-implantation reduces the rate of reinfection. From our point of view, the optimal timing for re-implantation depends on various specific factors and therefore it should be defined individually.
Outcome of total knee replacement following explantation and cemented spacer therapy
Ghanem, Mohamed; Zajonz, Dirk; Bollmann, Juliane; Geissler, Vanessa; Prietzel, Torsten; Moche, Michael; Roth, Andreas; Heyde, Christoph-E.; Josten, Christoph
2016-01-01
Background: Infection after total knee replacement (TKR) is one of the serious complications which must be pursued with a very effective therapeutic concept. In most cases this means revision arthroplasty, in which one-setting and two-setting procedures are distinguished. Healing of infection is the conditio sine qua non for re-implantation. This retrospective work presents an assessment of the success rate after a two-setting revision arthroplasty of the knee following periprosthetic infection. It further considers drawing conclusions concerning the optimal timing of re-implantation. Patients and methods: A total of 34 patients have been enclosed in this study from September 2005 to December 2013. 35 re-implantations were carried out following explantation of total knee and implantation of cemented spacer. The patient’s group comprised of 53% (18) males and 47% (16) females. The average age at re-implantation time was 72.2 years (ranging from 54 to 85 years). We particularly evaluated the microbial spectrum, the interval between explantation and re-implantation, the number of surgeries that were necessary prior to re-implantation as well as the postoperative course. Results: We reported 31.4% (11) reinfections following re-implantation surgeries. The number of the reinfections declined with increasing time interval between explantation and re-implantation. Patients who developed reinfections were operated on (re-implantation) after an average of 4.47 months. Those patients with uncomplicated course were operated on (re-implantation) after an average of 6.79 months. Nevertheless, we noticed no essential differences in outcome with regard to the number of surgeries carried out prior to re-implantation. Mobile spacers proved better outcome than temporary arthrodesis with intramedullary fixation. Conclusion: No uniform strategy of treatment exists after peri-prosthetic infections. In particular, no optimal timing can be stated concerning re-implantation. Our data point out to the fact that a longer time interval between explantation and re-implantation reduces the rate of reinfection. From our point of view, the optimal timing for re-implantation depends on various specific factors and therefore it should be defined individually. PMID:27066391
Optimization of Contrast Detection Power with Probabilistic Behavioral Information
Cordes, Dietmar; Herzmann, Grit; Nandy, Rajesh; Curran, Tim
2012-01-01
Recent progress in the experimental design for event-related fMRI experiments made it possible to find the optimal stimulus sequence for maximum contrast detection power using a genetic algorithm. In this study, a novel algorithm is proposed for optimization of contrast detection power by including probabilistic behavioral information, based on pilot data, in the genetic algorithm. As a particular application, a recognition memory task is studied and the design matrix optimized for contrasts involving the familiarity of individual items (pictures of objects) and the recollection of qualitative information associated with the items (left/right orientation). Optimization of contrast efficiency is a complicated issue whenever subjects’ responses are not deterministic but probabilistic. Contrast efficiencies are not predictable unless behavioral responses are included in the design optimization. However, available software for design optimization does not include options for probabilistic behavioral constraints. If the anticipated behavioral responses are included in the optimization algorithm, the design is optimal for the assumed behavioral responses, and the resulting contrast efficiency is greater than what either a block design or a random design can achieve. Furthermore, improvements of contrast detection power depend strongly on the behavioral probabilities, the perceived randomness, and the contrast of interest. The present genetic algorithm can be applied to any case in which fMRI contrasts are dependent on probabilistic responses that can be estimated from pilot data. PMID:22326984
Kutzner, I; Bender, A; Dymke, J; Duda, G; von Roth, P; Bergmann, G
2017-06-01
Tibiofemoral alignment is important to determine the rate of progression of osteoarthritis and implant survival after total knee arthroplasty (TKA). Normally, surgeons aim for neutral tibiofemoral alignment following TKA, but this has been questioned in recent years. The aim of this study was to evaluate whether varus or valgus alignment indeed leads to increased medial or lateral tibiofemoral forces during static and dynamic weight-bearing activities. Tibiofemoral contact forces and moments were measured in nine patients with instrumented knee implants. Medial force ratios were analysed during nine daily activities, including activities with single-limb support (e.g. walking) and double-limb support (e.g. knee bend). Hip-knee-ankle angles in the frontal plane were analysed using full-leg coronal radiographs. The medial force ratio strongly correlated with the tibiofemoral alignment in the static condition of one-legged stance (R² = 0.88) and dynamic single-limb loading (R² = 0.59) with varus malalignment leading to increased medial force ratios of up to 88%. In contrast, the correlation between leg alignment and magnitude of medial compartment force was much less pronounced. A lateral shift of force occurred during activities with double-limb support and higher knee flexion angles. The medial force ratio depends on both the tibiofemoral alignment and the nature of the activity involved. It cannot be generalised to a single value. Higher medial ratios during single-limb loading are associated with varus malalignment in TKA. The current trend towards a 'constitutional varus' after joint replacement, in terms of overall tibiofemoral alignment, should be considered carefully with respect to the increased medial force ratio. Cite this article: Bone Joint J 2017;99-B:779-87. ©2017 The British Editorial Society of Bone & Joint Surgery.
Loghmani, M Terry; Warden, Stuart J
2013-09-28
Ligament injuries are common clinical problems for which there are few established interventions. Instrument-assisted cross fiber massage (IACFM) was recently shown to accelerate the restoration of biomechanical properties in injured rodent knee medial collateral ligaments (MCL). The current study aimed to investigate the influence of IACFM on regional perfusion and vascularity in the vicinity of healing rodent knee MCL injuries. Bilateral knee MCL injuries were induced in female Sprague-Dawley rats. Commencing 1 week post-injury, 1 minute of IACFM was introduced unilaterally 3 times/week for 3 weeks. The contralateral injured MCL served as an internal control. Regional tissue perfusion was assessed in vivo throughout healing using laser Doppler imaging, whereas regional microvascular morphology was assessed ex vivo via micro-computed tomography of vessels filled with contrast. IACFM had no effect on tissue perfusion when assessed immediately, or at 5, 10, 15 or 20 min following intervention (all p > 0.05). However, IACFM-treated hindlimbs had enhanced tissue perfusion when assessed 1 day following the 4th and 9th (last) treatment sessions (all p < 0.05). IACFM-treated hindlimbs also had greater perfusion when assessed 1 wk following the final treatment session (32 days post-injury) (p < 0.05). Subsequent investigation of microvascular morphology found IACFM to increase the proportion of arteriole-sized blood vessels (5.9 to <41.2 μm) in the tibial third of the ligament (p < 0.05). These findings suggest IACFM alters regional perfusion and vascularity in the vicinity of healing rodent knee MCL injuries. This effect may contribute to the beneficial effect of IACFM observed on the recovery of knee ligament biomechanical properties following injury.
2013-01-01
Background Ligament injuries are common clinical problems for which there are few established interventions. Instrument-assisted cross fiber massage (IACFM) was recently shown to accelerate the restoration of biomechanical properties in injured rodent knee medial collateral ligaments (MCL). The current study aimed to investigate the influence of IACFM on regional perfusion and vascularity in the vicinity of healing rodent knee MCL injuries. Methods Bilateral knee MCL injuries were induced in female Sprague–Dawley rats. Commencing 1 week post-injury, 1 minute of IACFM was introduced unilaterally 3 times/week for 3 weeks. The contralateral injured MCL served as an internal control. Regional tissue perfusion was assessed in vivo throughout healing using laser Doppler imaging, whereas regional microvascular morphology was assessed ex vivo via micro-computed tomography of vessels filled with contrast. Results IACFM had no effect on tissue perfusion when assessed immediately, or at 5, 10, 15 or 20 min following intervention (all p > 0.05). However, IACFM-treated hindlimbs had enhanced tissue perfusion when assessed 1 day following the 4th and 9th (last) treatment sessions (all p < 0.05). IACFM-treated hindlimbs also had greater perfusion when assessed 1 wk following the final treatment session (32 days post-injury) (p < 0.05). Subsequent investigation of microvascular morphology found IACFM to increase the proportion of arteriole-sized blood vessels (5.9 to <41.2 μm) in the tibial third of the ligament (p < 0.05). Conclusions These findings suggest IACFM alters regional perfusion and vascularity in the vicinity of healing rodent knee MCL injuries. This effect may contribute to the beneficial effect of IACFM observed on the recovery of knee ligament biomechanical properties following injury. PMID:24073942
Lim, Hong-Chul; Yoon, Yong-Cheol; Wang, Joon-Ho; Bae, Ji-Hoon
2012-12-01
The purpose of this study was to compare the initial stability of anatomical and non-anatomical single bundle anterior cruciate ligament (ACL) reconstruction and to determine which would better restore intact knee kinematics. Our hypothesis was that the initial stability of anatomical single bundle ACL reconstruction would be superior to that of non-anatomical single bundle ACL reconstruction. Anterior tibial translation (ATT) and internal rotation of the tibia were measured with a computer navigation system in seven pairs of fresh-frozen cadaveric knees under two testing conditions (manual maximum anterior force, and a manual maximum anterior force combined with an internal rotational force). Tests were performed at 0, 30, 60, and 90 degrees of flexion with the ACL intact, the ACL transected, and after reconstruction of one side of a pair with either anatomical or non-anatomical single bundle ACL reconstruction. Under manual maximal anterior force, both reconstruction techniques showed no significant difference of ATT when compared to ACL intact knee state at 30° of knee flexion (p > 0.05). Under the combined anterior and internal rotatory force, non-anatomical single-bundle ACL reconstruction showed significant difference of ATT compared to those in ACL intact group (p < 0.05). In contrast, central anatomical single bundle ACL reconstruction showed no significant difference of ATT compared to those in ACL intact group (p > 0.05). Internal rotation of the tibia showed no significant difference in the ACL intact, the ACL transected, non-anatomical reconstructed and anatomical reconstructed knees. Anatomical single bundle ACL reconstruction restored the initial stability closer to the native ACL under combined anterior and internal rotational forces when compared to non-anatomical ACL single bundle reconstruction.
Ling, Barbara M; Wettstein, Reto; Staub, Daniel; Schaefer, Dirk J; Kalbermatten, Daniel F
2018-02-07
The gastrocnemius muscle flap may be considered the first choice in many cases of soft-tissue reconstruction about the knee. Limited arc of rotation and reach of the flap as well as unsightly muscle bulk are major disadvantages and were the impetus to look for a local alternative. The aim of this study is to present a consecutive series of patients with a reconstruction about the knee involving the medial sural artery perforator flap (MSAPF). A consecutive series of 17 cases of defect reconstructions about the knee using the MSAPF is described, with an emphasis on early postoperative complications. No major flap-related complications occurred except 1 case of tip necrosis that healed uneventfully after excision and secondary suture. Two patients with direct donor-site closure had a minor complication that required no revision, and 2 had partial skin-graft loss. In summary, use of this pedicled perforator flap represents a reliable technique for soft-tissue reconstruction about the knee with an acceptable complication rate and optimal contour reconstruction without the need for a skin graft and secondary debulking procedures. The range of motion associated with the MSAPF in comparison to the range associated with the gastrocnemius muscle flap is increased so that more proximal and lateral defects can be covered. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Wagner, Till; Hupkens, Pieter; Slater, Nicholas J; Ulrich, Dietmar J O
2016-04-01
Coverage of soft-tissue defects of the knee due to multiple operations, trauma, and infection remains a surgical challenge. Often, these defects are repaired using free tissue transfer. The aim of this study was to find an easy and reliable local method of repair for small to medium-sized defects. The authors describe a new surgical option for tissue coverage using a proximally based long peroneal muscle turnover flap (LPTF) with split-thickness skin graft. Proximally based LPTFs were harvested and transposed into same-size created defects in five cadavers. After optimizing this technique, it was clinically used in two patients with defects secondary to total knee replacement revisions. Average cadaver flap size was 4.7 × 15.8 cm allowing reach of all knee joint areas and was based consistently on a sufficient (2-mm-diameter average) proximal arterial branch of the anterior tibial artery. Donor sites were closed without tension. Subsequent application of the flap on two patients resulted in good functional outcome. The proximally based LPTF is a new option available in the reconstruction of knee defects and should be added to the reconstructive surgeon's armamentarium of pedicled flaps, providing short operating time and promising clinical outcome. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Halonen, K S; Mononen, M E; Jurvelin, J S; Töyräs, J; Salo, J; Korhonen, R K
2014-07-18
Novel conical beam CT-scanners offer high resolution imaging of knee structures with i.a. contrast media, even under weight bearing. With this new technology, we aimed to determine cartilage strains and meniscal movement in a human knee at 0, 1, 5, and 30 min of standing and compare them to the subject-specific 3D finite element (FE) model. The FE model of the volunteer׳s knee, based on the geometry obtained from magnetic resonance images, was created to simulate the creep. The effects of collagen fibril network stiffness, nonfibrillar matrix modulus, permeability and fluid flow boundary conditions on the creep response in cartilage were investigated. In the experiment, 80% of the maximum strain in cartilage developed immediately, after which the cartilage continued to deform slowly until the 30 min time point. Cartilage strains and meniscus movement obtained from the FE model matched adequately with the experimentally measured values. Reducing the fibril network stiffness increased the mean strains substantially, while the creep rate was primarily influenced by an increase in the nonfibrillar matrix modulus. Changing the initial permeability and preventing fluid flow through noncontacting surfaces had a negligible effect on cartilage strains. The present results improve understanding of the mechanisms controlling articular cartilage strains and meniscal movements in a knee joint under physiological static loading. Ultimately a validated model could be used as a noninvasive diagnostic tool to locate cartilage areas at risk for degeneration. Copyright © 2014 Elsevier Ltd. All rights reserved.
Restoring tibiofemoral alignment during ACL reconstruction results in better knee biomechanics.
Zampeli, Frantzeska; Terzidis, Ioannis; Espregueira-Mendes, João; Georgoulis, Jim-Dimitris; Bernard, Manfred; Pappas, Evangelos; Georgoulis, Anastasios D
2018-05-01
Anterior cruciate ligament (ACL) reconstruction (ACLR) aims to restore normal knee joint function, stability and biomechanics and in the long term avoid joint degeneration. The purpose of this study is to present the anatomic single bundle (SB) ACLR that emphasizes intraoperative correction of tibiofemoral subluxation that occurs after ACL injury. It was hypothesized that this technique leads to optimal outcomes and better restoration of pathological tibiofemoral joint movement that results from ACL deficiency (ACLD). Thirteen men with unilateral ACLD were prospectively evaluated before and at a mean follow-up of 14.9 (SD = 1.8) months after anatomic SB ACLR with bone patellar tendon bone autograft. The anatomic ACLR replicated the native ACL attachment site anatomy and graft orientation. Emphasis was placed on intraoperative correction of tibiofemoral subluxation by reducing anterior tibial translation (ATT) and internal tibial rotation. Function was measured with IKDC, Lysholm and the Tegner activity scale, ATT was measured with the KT-1000 arthrometer and tibial rotation (TR) kinematics were measured with 3Dmotion analysis during a high-demand pivoting task. The results showed significantly higher TR of the ACL-deficient knee when compared to the intact knee prior to surgery (12.2° ± 3.7° and 10.7° ± 2.6° respectively, P = 0.014). Postoperatively, the ACLR knee showed significantly lower TR as compared to the ACL-deficient knee (9.6°±3.1°, P = 0.001) but no difference as compared to the control knee (n.s.). All functional scores were significantly improved and ATT was restored within normal values (P < 0.001). Intraoperative correction of tibiofemoral subluxation that results after ACL injury is an important step during anatomic SB ACLR. The intraoperative correction of tibiofemoral subluxation along with the replication of native ACL anatomy results in restoration of rotational kinematics of ACLD patients to normal levels that are comparable to the control knee. These results indicate that the reestablishment of tibiofemoral alignment during ACLR may be an important step that facilitates normal knee kinematics postoperatively. Level II, prospective cohort study.
Butler, Aaron; Olson, Tyson; Koehler, Ryan; Nicandri, Gregg
2013-02-06
The use of surgical simulation in orthopaedic education is increasing; however, its ideal place within the training curriculum remains unknown. The purpose of this study was to determine the effectiveness of training novice surgeons on an anatomic dry model of the knee prior to training them to perform diagnostic arthroscopy on cadaveric specimens. Fourteen medical students were randomly assigned to two groups. The experimental group was trained to perform diagnostic arthroscopy of the knee on anatomic dry models prior to training on cadaveric specimens. The control group was trained only on cadaveric specimens. Proficiency was assessed with use of a modified version of a previously validated objective assessment of arthroscopic skill, the Basic Arthroscopic Knee Skill Scoring System (BAKSSS). The mean number of trials required to attain minimal proficiency when performing diagnostic knee arthroscopy was compared between the groups. The cumulative transfer effectiveness ratio (CTER) was calculated to measure the transfer of skills acquired by the experimental group. The mean number of trials to demonstrate minimum proficiency was significantly lower in the experimental group (2.57) than in the control group (4.57) (p < 0.01). The mean time to demonstrate proficiency was also significantly less in the experimental group (37.51 minutes) than in the control group (60.48 minutes) (p < 0.01). The CTER of dry-model training for the task of performing diagnostic knee arthroscopy on cadaveric specimens was 0.2. Previous training utilizing an anatomic dry knee model resulted in improved proficiency for novice surgeons learning to perform diagnostic knee arthroscopy on cadaveric specimens. A CTER of 0.2 suggests that dry models can serve as a useful adjunct to cadaveric training for diagnostic knee arthroscopy but cannot entirely replace it within the orthopaedic curriculum. Further work is necessary to determine the optimal amount of training on anatomic dry models that will maximize transfer effectiveness and to determine how well skills obtained in the simulated environment transfer to the operating room.
Tan, Siok Swan; Chiarello, Pietro; Quentin, Wilm
2013-11-01
Researchers from 11 countries (Austria, England, Estonia, Finland, France, Germany, Ireland, Netherlands, Poland, Spain, and Sweden) compared how their Diagnosis-Related Group (DRG) systems deal with knee replacement cases. The study aims to assist knee surgeons and national authorities to optimize the grouping algorithm of their DRG systems. National or regional databases were used to identify hospital cases treated with a procedure of knee replacement. DRG classification algorithms and indicators of resource consumption were compared for those DRGs that together comprised at least 97 % of cases. Five standardized case scenarios were defined and quasi-prices according to national DRG-based hospital payment systems ascertained. Grouping algorithms for knee replacement vary widely across countries: they classify cases according to different variables (between one and five classification variables) into diverging numbers of DRGs (between one and five DRGs). Even the most expensive DRGs generally have a cost index below 2.00, implying that grouping algorithms do not adequately account for cases that are more than twice as costly as the index DRG. Quasi-prices for the most complex case vary between euro 4,920 in Estonia and euro 14,081 in Spain. Most European DRG systems were observed to insufficiently consider the most important determinants of resource consumption. Several countries' DRG system might be improved through the introduction of classification variables for revision of knee replacement or for the presence of complications or comorbidities. Ultimately, this would contribute to assuring adequate performance comparisons and fair hospital reimbursement on the basis of DRGs.
What is the effect of physical activity on the knee joint? A systematic review.
Urquhart, Donna M; Tobing, Jephtah F L; Hanna, Fahad S; Berry, Patricia; Wluka, Anita E; Ding, Changhai; Cicuttini, Flavia M
2011-03-01
Although several studies have examined the relationship between physical activity and knee osteoarthritis, the effect of physical activity on knee joint health is unclear. The aim of this systematic review was to examine the relationships between physical activity and individual joint structures at the knee. Computer-aided searches were conducted up until November 2008, and the reference lists of key articles were examined. The methodological quality of selected studies was assessed based on established criteria, and a best-evidence synthesis was used to summarize the results. We found that the relationships between physical activity and individual joint structures at the knee differ. There was strong evidence for a positive association between physical activity and tibiofemoral osteophytes. However, we also found strong evidence for the absence of a relationship between physical activity and joint space narrowing, a surrogate method of assessing cartilage. Moreover, there was limited evidence from magnetic resonance imaging studies for a positive relationship between physical activity and cartilage volume and strong evidence for an inverse relationship between physical activity and cartilage defects. This systematic review found that knee structures are affected differently by physical activity. Although physical activity is associated with an increase in radiographic osteophytes, there was no related increase in joint space narrowing, rather emerging evidence of an associated increase in cartilage volume and decrease in cartilage defects on magnetic resonance imaging. Given that optimizing cartilage health is important in preventing osteoarthritis, these findings indicate that physical activity is beneficial, rather than detrimental, to joint health.
Cameron, Kenneth L; Peck, Karen Y; Thompson, Brandon S; Svoboda, Steven J; Owens, Brett D; Marshall, Stephen W
2015-01-01
Activity-related patient-reported outcome measures are an important component of assessment after knee ligament injury in young and physically active patients; however, normative data for most activity scales are limited. To present reference values by sex for the Marx Activity Rating Scale (MARS) within a young and physically active population while accounting for knee ligament injury history and sex. Cross-sectional study. Level 2. All incoming freshman entering a US Service Academy in June of 2011 were recruited to participate in this study. MARS was administered to 1169 incoming freshmen (203 women) who consented to participate within the first week of matriculation. All subjects were deemed healthy and medically fit for military service on admission. Subjects also completed a baseline questionnaire that asked for basic demographic information and injury history. We calculated means with standard deviations, medians with interquartile ranges, and percentiles for ordinal and continuous variables, and frequencies and proportions for dichotomous variables. We also compared median scores by sex and history of knee ligament injury using the Kruskal-Wallis test. MARS was the primary outcome of interest. The median MARS score was significantly higher for men when compared with women (χ(2) = 13.22, df = 1, P < 0.001) with no prior history of knee ligament injury. In contrast, there was no significant difference in median MARS scores between men and women (χ(2) = 0.47, df = 1, P = 0.493) who reported a history of injury. Overall, median MARS scores were significantly higher among those who reported a history of knee ligament injury when compared with those who did not (χ(2) = 9.06, df = 1, P = 0.003). Assessing activity as a patient-reported outcome after knee ligament injury is important, and reference values for these instruments need to account for the influence of prior injury and sex. © 2015 The Author(s).
Hoogeslag, Roy A G; Brouwer, Reinoud W; Huis In 't Veld, Rianne; Stephen, Joanna M; Amis, Andrew A
2018-02-03
There is a lack of objective evidence investigating how previous non-augmented ACL suture repair techniques and contemporary augmentation techniques in ACL suture repair restrain anterior tibial translation (ATT) across the arc of flexion, and after cyclic loading of the knee. The purpose of this work was to test the null hypotheses that there would be no statistically significant difference in ATT after non-, static- and dynamic-augmented ACL suture repair, and they will not restore ATT to normal values across the arc of flexion of the knee after cyclic loading. Eleven human cadaveric knees were mounted in a test rig, and knee kinematics from 0° to 90° of flexion were recorded by use of an optical tracking system. Measurements were recorded without load and with 89-N tibial anterior force. The knees were tested in the following states: ACL-intact, ACL-deficient, non-augmented suture repair, static tape augmentation and dynamic augmentation after 10 and 300 loading cycles. Only static tape augmentation and dynamic augmentation restored ATT to values similar to the ACL-intact state directly postoperation, and maintained this after cyclic loading. However, contrary to dynamic augmentation, the ATT after static tape augmentation failed to remain statistically less than for the ACL-deficient state after cyclic loading. Moreover, after cyclic loading, ATT was significantly less with dynamic augmentation when compared to static tape augmentation. In contrast to non-augmented ACL suture repair and static tape augmentation, only dynamic augmentation resulted in restoration of ATT values similar to the ACL-intact knee and decreased ATT values when compared to the ACL-deficient knee immediately post-operation and also after cyclic loading, across the arc of flexion, thus allowing the null hypotheses to be rejected. This may assist healing of the ruptured ACL. Therefore, this study would support further clinical evaluation of dynamic augmentation of ACL repair.
Choi, Chong Hyuk; Kim, Sung-Jae; Chun, Yong-Min; Kim, Sung-Hwan; Lee, Su-Keon; Eom, Nam-Kyu; Jung, Min
2018-01-01
The purpose of this study was to find appropriate flexion angle and transverse drill angle for optimal femoral tunnels of anteromedial (AM) bundle and posterolateral (PL) bundle in double-bundle ACL reconstruction using transportal technique. Thirty three-dimensional knee models were reconstructed. Knee flexion angles were altered from 100° to 130° at intervals of 10°. Maximum transverse drill angle (MTA), MTA minus 10° and 20° were set up. Twelve different tunnels were determined by four flexion angles and three transverse drill angles for each bundle. Tunnel length, wall breakage, inter-tunnel communication and graft-bending angle were assessed. Mean tunnel length of AM bundle was >30mm at 120° and 130° of flexion in all transverse drill angles. Mean tunnel length of PL bundle was >30mm during every condition. There were ≥1 cases of wall breakage except at 120° and 130° of flexion with MTA for AM bundle. There was no case of wall breakage for PL bundle. Considering inter-tunnel gap of >2mm without communication and obtuse graft-bending angle, 120° of flexion and MTA could be recommended as optimal condition for femoral tunnels of AM and PL bundles. Flexion angle and transverse drill angle had combined effect on femoral tunnel in double-bundle ACL reconstruction using transportal technique. Achieving flexion angle of 120° and transverse drill angle close to the medial femoral condyle could be recommended as optimal condition for femoral tunnels of AM and PL bundles to avoid insufficient tunnel length, wall breakage, inter-tunnel communication and acute graft-bending angle. Copyright © 2017 Elsevier B.V. All rights reserved.
Rotationplasty with vascular reconstruction for prosthetic knee joint infection.
Fujiki, Masahide; Miyamoto, Shimpei; Nakatani, Fumihiko; Kawai, Akira; Sakuraba, Minoru
2015-01-01
Rotationplasty is used most often as a function-preserving salvage procedure after resection of sarcomas of the lower extremity; however, it is also used after infection of prosthetic knee joints. Conventional vascular management during rotationplasty is to preserve and coil major vessels, but recently, transection and reanastomosis of the major vessels has been widely performed. However, there has been little discussion regarding the optimal vascular management of rotationplasty after infection of prosthetic knee joints because rotationplasty is rarely performed for this indication. We reviewed four patients who had undergone resection of osteosarcomas of the femur, placement of a prosthetic knee joint, and rotationplasty with vascular reconstruction from 2010 to 2013. The mean interval between prosthetic joint replacement and rotationplasty was 10.4 years and the mean interval between the diagnosis of prosthesis infection and rotationplasty was 7.9 years. Rotationplasty was successful in all patients; however, in one patient, arterial thrombosis developed and necessitated urgent surgical removal and arterial reconstruction. All patients were able to walk independently with a prosthetic limb after rehabilitation. Although there is no consensus regarding the most appropriate method of vascular management during rotationplasty for revision of infected prosthetic joints, vascular transection and reanastomosis is a useful option.
Biomechanical consequences of a nonanatomic posterior medial meniscal root repair.
LaPrade, Christopher M; Foad, Abdullah; Smith, Sean D; Turnbull, Travis Lee; Dornan, Grant J; Engebretsen, Lars; Wijdicks, Coen A; LaPrade, Robert F
2015-04-01
Posterior medial meniscal root tears have been reported to extrude with the meniscus becoming adhered posteromedially along the posterior capsule. While anatomic repair has been reported to restore tibiofemoral contact mechanics, it is unknown whether nonanatomic positioning of a meniscal root repair to a posteromedial location would restore the loading profile of the knee joint. The purpose of this study was to compare the tibiofemoral contact mechanics of a nonanatomic posterior medial meniscal tear with that of the intact knee or anatomic repair. It was hypothesized that a nonanatomic root repair would not restore the tibiofemoral contact pressures and areas to that of the intact or anatomic repair state. Controlled laboratory study. Tibiofemoral contact mechanics were recorded in 6 male human cadaveric knee specimens (average age, 45.8 years) using pressure sensors. Each knee underwent 5 testing conditions for the posterior medial meniscal root: (1) intact knee; (2) root tear; (3) anatomic transtibial pull-out repair; (4) nonanatomic transtibial pull-out repair, placed 5 mm posteromedially along the edge of the articular cartilage; and (5) root tear concomitant with an ACL tear. Knees were loaded with a 1000-N axial compressive force at 4 flexion angles (0°, 30°, 60°, 90°), and contact area, mean contact pressure, and peak contact pressure were calculated. Contact area was significantly lower after nonanatomic repair than for the intact knee at all flexion angles (mean = 44% reduction) and significantly higher for anatomic versus nonanatomic repair at all flexion angles (mean = 27% increase). At 0° and 90°, and when averaged across flexion angles, the nonanatomic repair significantly increased mean contact pressures in comparison to the intact knee or anatomic repair. When averaged across flexion angles, the peak contact pressures after nonanatomic repair were significantly higher than the intact knee but not the anatomic repair. In contrast, when averaged across all flexion angles, the anatomic repair resulted in a 17% reduction in contact area and corresponding increases in mean and peak contact pressures of 13% and 26%, respectively, compared with the intact knee. For most testing conditions, the nonanatomic repair did not restore the contact area or mean contact pressures to that of the intact knee or anatomic repair. However, the anatomic repair produced near-intact contact area and resulted in relatively minimal increases in mean and peak contact pressures compared with the intact knee. Results emphasize the importance of ensuring an anatomic posterior medial meniscal root repair by releasing the extruded menisci from adhesions and the posteromedial capsule. Similar caution toward preventing displacement of the meniscal root repair construct should be emphasized. © 2015 The Author(s).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muehleman,C.; Li, J.; Zhong, Z.
2006-01-01
Objective: To demonstrate the ability of a novel radiographic technique, Diffraction Enhanced Radiographic Imaging (DEI), to render high contrast images of canine knee joints for identification of cartilage lesions in situ. Methods: DEI was carried out at the X-15A beamline at Brookhaven National Laboratory on intact canine knee joints with varying levels of cartilage damage. Two independent observers graded the DE images for lesions and these grades were correlated to the gross morphological grade. Results: The correlation of gross visual grades with DEI grades for the 18 canine knee joints as determined by observer 1 (r2=0.8856, P=0.001) and observer 2more » (r2=0.8818, P=0.001) was high. The overall weighted ? value for inter-observer agreement was 0.93, thus considered high agreement. Conclusion: The present study is the first study for the efficacy of DEI for cartilage lesions in an animal joint, from very early signs through erosion down to subchondral bone, representing the spectrum of cartilage changes occurring in human osteoarthritis (OA). Here we show that DEI allows the visualization of cartilage lesions in intact canine knee joints with good accuracy. Hence, DEI may be applicable for following joint degeneration in animal models of OA.« less
Detection of Prosthetic Knee Movement Phases via In-Socket Sensors: A Feasibility Study
El-Sayed, Amr M.; Tan, Kenneth Y. S.; Abu Osman, Noor Azuan
2015-01-01
This paper presents an approach of identifying prosthetic knee movements through pattern recognition of mechanical responses at the internal socket's wall. A quadrilateral double socket was custom made and instrumented with two force sensing resistors (FSR) attached to specific anterior and posterior sites of the socket's wall. A second setup was established by attaching three piezoelectric sensors at the anterior distal, anterior proximal, and posterior sites. Gait cycle and locomotion movements such as stair ascent and sit to stand were adopted to characterize the validity of the technique. FSR and piezoelectric outputs were measured with reference to the knee angle during each phase. Piezoelectric sensors could identify the movement of midswing and terminal swing, pre-full standing, pull-up at gait, sit to stand, and stair ascent. In contrast, FSR could estimate the gait cycle stance and swing phases and identify the pre-full standing at sit to stand. FSR showed less variation during sit to stand and stair ascent to sensitively represent the different movement states. The study highlighted the capacity of using in-socket sensors for knee movement identification. In addition, it validated the efficacy of the system and warrants further investigation with more amputee subjects and different sockets types. PMID:25945365
Hotchen, Andrew J; Demetriou, Charis; Edwards, Dennis; Melton, Joel T K
2018-06-13
The presentation and clinical course of mucoid degeneration of the anterior cruciate ligament (MD-ACL) are poorly documented within the literature. Subsequently, it is under-diagnosed and the optimal management strategy remains ill-defined. Here, we characterize the syndrome associated with MD-ACL and compare the natural clinical course with the outcomes of arthroscopic management. Thirty-one patients with radiological features of MD-ACL over a 2-year period had their clinical notes retrospectively reviewed. Seven patients underwent arthroscopic debridement of the ACL for MD. These were followed up for a minimum of 2 years and an average of 2.8 years from surgery. The remainder were managed conservatively ( n = 24) and were followed up for a minimum of 2 years and an average of 4.0 years. The notch width index (NWI) and associated pathology was noted. Primary outcome measures were presence of knee pain and use of analgesia. Secondary outcome measures were the Oxford and Lysholm knee scores. The most commonly reported symptoms were posterior knee pain (77.4%) and limitation of terminal flexion (58.1%). All patients who underwent arthroscopic debridement were pain and analgesia free at follow-up. Of the patients who did not undergo arthroscopic surgery, three patients had knee replacement surgery and three were lost to follow-up. The remaining patients, 14/18 (77.8%), reported knee pain and regular analgesia use at follow-up, which was significantly more than the arthroscopic debridement group ( p < 0.01). The knee scores were significantly better in the arthroscopic debridement group at follow-up (Oxford knee score: 45 vs 34; Lysholm: 92 vs 67; p < 0.01). Furthermore, the postoperative improvement in the Oxford knee and Lysholm scores compared with preoperatively was 12.1 and 31.8 points, respectively ( p < 0.01). The NWI was increased in patients with mild-to-severe osteoarthritis (0.266 vs 0.273; p < 0.05). MD-ACL should be considered in patients who report posterior knee pain, limitation of terminal flexion, and it can be associated with other knee pathologies. MD-ACL can be successfully managed with arthroscopic radio frequency debulking with improvement in quality of life at follow-up. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
The Evolution of Image-Free Robotic Assistance in Unicompartmental Knee Arthroplasty.
Lonner, Jess H; Moretti, Vincent M
2016-01-01
Semiautonomous robotic technology has been introduced to optimize accuracy of bone preparation, implant positioning, and soft tissue balance in unicompartmental knee arthroplasty (UKA), with the expectation that there will be a resultant improvement in implant durability and survivorship. Currently, roughly one-fifth of UKAs in the US are being performed with robotic assistance, and it is anticipated that there will be substantial growth in market penetration of robotics over the next decade. First-generation robotic technology improved substantially implant position compared to conventional methods; however, high capital costs, uncertainty regarding the value of advanced technologies, and the need for preoperative computed tomography (CT) scans were barriers to broader adoption. Newer image-free semiautonomous robotic technology optimizes both implant position and soft tissue balance, without the need for preoperative CT scans and with pricing and portability that make it suitable for use in an ambulatory surgery center setting, where approximately 40% of these systems are currently being utilized. This article will review the robotic experience for UKA, including rationale, system descriptions, and outcomes.
Goodman, Susan M; Springer, Bryan; Guyatt, Gordon; Abdel, Matthew P; Dasa, Vinod; George, Michael; Gewurz-Singer, Ora; Giles, Jon T; Johnson, Beverly; Lee, Steve; Mandl, Lisa A; Mont, Michael A; Sculco, Peter; Sporer, Scott; Stryker, Louis; Turgunbaev, Marat; Brause, Barry; Chen, Antonia F; Gililland, Jeremy; Goodman, Mark; Hurley-Rosenblatt, Arlene; Kirou, Kyriakos; Losina, Elena; MacKenzie, Ronald; Michaud, Kaleb; Mikuls, Ted; Russell, Linda; Sah, Alexander; Miller, Amy S; Singh, Jasvinder A; Yates, Adolph
2017-08-01
This collaboration between the American College of Rheumatology and the American Association of Hip and Knee Surgeons developed an evidence-based guideline for the perioperative management of antirheumatic drug therapy for adults with rheumatoid arthritis (RA), spondyloarthritis (SpA) including ankylosing spondylitis and psoriatic arthritis, juvenile idiopathic arthritis (JIA), or systemic lupus erythematosus (SLE) undergoing elective total hip (THA) or total knee arthroplasty (TKA). A panel of rheumatologists, orthopedic surgeons specializing in hip and knee arthroplasty, and methodologists was convened to construct the key clinical questions to be answered in the guideline. A multi-step systematic literature review was then conducted, from which evidence was synthesized for continuing versus withholding antirheumatic drug therapy and for optimal glucocorticoid management in the perioperative period. A Patient Panel was convened to determine patient values and preferences, and the Grading of Recommendations Assessment, Development and Evaluation methodology was used to rate the quality of evidence and the strength of recommendations, using a group consensus process through a convened Voting Panel of rheumatologists and orthopedic surgeons. The strength of the recommendation reflects the degree of certainty that benefits outweigh harms of the intervention, or vice versa, considering the quality of available evidence and the variability in patient values and preferences. The guideline addresses the perioperative use of antirheumatic drug therapy including traditional disease-modifying antirheumatic drugs, biologic agents, tofacitinib, and glucocorticoids in adults with RA, SpA, JIA, or SLE who are undergoing elective THA or TKA. It provides recommendations regarding when to continue, when to withhold, and when to restart these medications, and the optimal perioperative dosing of glucocorticoids. The guideline includes 7 recommendations, all of which are conditional and based on low- or moderate-quality evidence. This guideline should help decision-making by clinicians and patients regarding perioperative antirheumatic medication management at the time of elective THA or TKA. These conditional recommendations reflect the paucity of high-quality direct randomized controlled trial data. © 2017, American College of Rheumatology.
Wenham, C Y J; Balamoody, S; Grainger, A J; Hensor, E M A; Draycott, S; Hodgson, R; Conaghan, P G
2014-10-01
Sensitive biomarkers are needed to understand synovial response to therapy in osteoarthritis (OA). Dynamic, contrast-enhanced magnetic resonance imaging (DCE MRI) provides quantitative, novel measures of synovial inflammation. This exploratory study examined DCE-assessed synovial response to intra-articular corticosteroid (IACS). People with ACR clinical criteria OA knee underwent 3 T MRI pre- and 2 weeks post-IACS. Five MRI variables were assessed blindly: total synovial volume (semi-automated computer program), early enhancement rate (EER) and late enhancement ratio of the entire knee, synovial volume × late enhancement and a semi-quantitative (SQ) score (six sites scored 0-3). Clinical symptoms were assessed using pain visual analogue score (VAS) and WOMAC. 13 participants (5 male, mean age 63, mean pain VAS 66 mm mean body mass index (BMI) 31.3 kg/m(2)) were included. The majority of MRIs demonstrated no change in SQ score although the DCE variables changed to some extent in all. There was generally a reduction in synovial volume ((Wilcoxon test) median (interquartile range (IQR)) reduction 14 cm(3) (-1, 29)), EER (0.2% (-0.3, 0.6)) and late enhancement ratio (8% (-0.5, 41)). Synovial volume × late enhancement ratio demonstrated a substantive reduction (2250 (-930, 5630)) as well as the largest effect size, r = 0.45. There was a median 26% reduction in EER in participants with good symptomatic response to IACS, contrasting with a 23% increase in those who responded poorly. DCE MRI may be more sensitive than a SQ score at detecting post-therapy synovial changes. The association between EER and symptomatic response to IACS may reflect a closer relation of this biomarker to synovial inflammation than with volumetric assessment. Copyright © 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Riis, R G C; Gudbergsen, H; Simonsen, O; Henriksen, M; Al-Mashkur, N; Eld, M; Petersen, K K; Kubassova, O; Bay Jensen, A C; Damm, J; Bliddal, H; Arendt-Nielsen, L; Boesen, M
2017-02-01
To investigate the association between magnetic resonance imaging (MRI), macroscopic and histological assessments of synovitis in end-stage knee osteoarthritis (KOA). Synovitis of end-stage osteoarthritic knees was assessed using non-contrast-enhanced (CE), contrast-enhanced magnetic resonance imaging (CE-MRI) and dynamic contrast-enhanced (DCE)-MRI prior to (TKR) and correlated with microscopic and macroscopic assessments of synovitis obtained intraoperatively. Multiple bivariate correlations were used with a pre-specified threshold of 0.70 for significance. Also, multiple regression analyses with different subsets of MRI-variables as explanatory variables and the histology score as outcome variable were performed with the intention to find MRI-variables that best explain the variance in histological synovitis (i.e., highest R 2 ). A stepped approach was taken starting with basic characteristics and non-CE MRI-variables (model 1), after which CE-MRI-variables were added (model 2) with the final model also including DCE-MRI-variables (model 3). 39 patients (56.4% women, mean age 68 years, Kellgren-Lawrence (KL) grade 4) had complete MRI and histological data. Only the DCE-MRI variable MExNvoxel (surrogate of the volume and degree of synovitis) and the macroscopic score showed correlations above the pre-specified threshold for acceptance with histological inflammation. The maximum R 2 -value obtained in Model 1 was R 2 = 0.39. In Model 2, where the CE-MRI-variables were added, the highest R 2 = 0.52. In Model 3, a four-variable model consisting of the gender, one CE-MRI and two DCE-MRI-variables yielded a R 2 = 0.71. DCE-MRI is correlated with histological synovitis in end-stage KOA and the combination of CE and DCE-MRI may be a useful, non-invasive tool in characterising synovitis in KOA. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Hua, Xingyi; Tao, Hui; Fang, Wang; Tang, Jian
2016-01-22
Multiple-ligament injured knee (MLIK) is a rare but severe injury. Although the principles of MLIK management have progressed over the past 40 years, there is a paucity of high-quality evidence upon which to base the management of MLIK. Treatment strategies for MLIK are challenging for most orthopedic surgeons, and the optimal treatment remains controversial, especially with regard to repair vs. reconstruction of the ligaments. The aim of the present study was to observe clinical outcomes of single-stage in situ suture repair of knee dislocation with multiple-ligament injury using nonabsorbable suture material. Consecutive patients with MLIK between 2002 and 2010 were included, for a total of 25 patients with knee dislocation. 17 patients (18 knees) with closed knee dislocation with a mean follow-up of 4.8 ± 1.3 years were retrospective analyzed. All patients were treated surgically with single-stage in situ suture repair for all injured ligaments and followed a standardized postoperative rehabilitation protocol. The VAS score, satisfactory score, total SF-36 score, Lysholm score, Tegner score, the Meyers functional rating and the ranges of motion and knee stability were used to evaluate outcomes. At final follow-up, mean visual analog scale score was 2.4 ± 0.9, patient satisfaction score was 8.0 ± 1.1, 36-item Short-Form Health Survey total score was 85.5 ± 10.4, and mean Lysholm score was 87.5 ± 7.7. There were significant differences between mean preinjury and postoperative Tegner activity scores (5.6 ± 1.4 and 3.4 ± 1.7, respectively; P < 0.01) and in mean range of motion between the injured and contralateral knees (112.5 ± 8.4° and 129.6 ± 10.3°, respectively; P < 0.01). At final follow-up, no patient demonstrated obvious ligamentous laxity, and only one patient was unable to return to work. Three patients had knee joint stiffness, two had wound problems (infection or fat liquefaction), and two had heterotopic bone formation. Single-stage in situ suture repair of injured ligaments confers advantages of reliable fixation and early exercise. It could be considered as an alternate and effective option in the dislocation knee with multiple-ligament injury.
Wasserstein, David; Henry, Patrick; Paterson, J Michael; Kreder, Hans J; Jenkinson, Richard
2014-01-15
The aims of operative treatment of displaced tibial plateau fractures are to stabilize the injured knee to restore optimal function and to minimize the risk of posttraumatic arthritis and the eventual need for total knee arthroplasty. The purpose of our study was to define the rate of subsequent total knee arthroplasty after tibial plateau fractures in a large cohort and to compare that rate with the rate in the general population. All patients sixteen years of age or older who had undergone surgical treatment of a tibial plateau fracture from 1996 to 2009 in the province of Ontario, Canada, were identified from administrative health databases with use of surgeon fee codes. Each member of the tibial plateau fracture cohort was matched to four individuals from the general population according to age, sex, income, and urban/rural residence. The rates of total knee arthroplasty at two, five, and ten years were compared by using time-to-event analysis. A separate Cox proportional hazards model was used to explore the influence of patient, provider, and surgical factors on the time to total knee arthroplasty. We identified 8426 patients (48.5% female; median age, 48.9 years) who had undergone fixation of a tibial plateau fracture and matched them to 33,698 controls. The two, five, and ten-year rates of total knee arthroplasty in the plateau fracture and control cohorts were 0.32% versus 0.29%, 5.3% versus 0.82%, and 7.3% versus 1.8%, respectively (p < 0.0001). After adjustment for comorbidity, plateau fracture surgery was found to significantly increase the likelihood of total knee arthroplasty (hazard ratio [HR], 5.29 [95% confidence interval, 4.58, 6.11]; p < 0.0001). Higher rates of total knee arthroplasty were also associated with increasing age (HR, 1.03 [1.03, 1.04] per year over the age of forty-eight; p < 0.0001), bicondylar fracture (HR, 1.53 [1.26, 1.84]; p < 0.0001), and greater comorbidity (HR, 2.17 [1.70, 2.77]; p < 0.001). Ten years after tibial plateau fracture surgery, 7.3% of the patients had had a total knee arthroplasty. This corresponds to a 5.3 times increase in likelihood compared with a matched group from the general population. Older patients and those with more severe fractures are also more likely to need total knee arthroplasty after repair of a tibial plateau fracture.
Tsubosaka, Masanori; Matsushita, Takehiko; Kuroda, Ryosuke; Matsumoto, Tomoyuki; Kurosaka, Masahiro
2017-09-01
This report describes a case of a pseudoaneurysm of the articular branch of the descending genicular artery following double-bundle anterior cruciate ligament (ACL) reconstruction. An 18-year-old male received double-bundle ACL reconstruction. During ACL reconstruction, a far anteromedial portal was created for femoral tunnel drilling. The patient presented with pulsatile swelling on the medial side of the knee on the second post-operative day. The pseudoaneurysm was diagnosed using contrast computed tomography and Doppler ultrasonography and was subsequently treated by embolization with a microcatheter. Although a vascular injury is a very rare complication of knee arthroscopy, it should be considered a possibility in patients who undergo such procedures. V.
The relative cost of bent-hip bent-knee walking is reduced in water.
Kuliukas, Algis V; Milne, Nick; Fournier, Paul
2009-01-01
The debate about how early hominids walked may be characterised as two competing hypotheses: They moved with a fully upright (FU) gait, like modern humans, or with a bent-hip, bent-knee (BK) gait, like apes. Both have assumed that this bipedalism was almost exclusively on land, in trees or a combination of the two. Recent findings favoured the FU hypothesis by showing that the BK gait is 50-60% more energetically costly than a FU human gait on land. We confirm these findings but show that in water this cost differential is markedly reduced, especially in deeper water, at slower speeds and with greater knee flexion. These data suggest that the controversy about australopithecine locomotion may be eased if it is assumed that wading was a component of their locomotor repertoire and supports the idea that shallow water might have been an environment favourable to the evolution of early forms of "non-optimal" hominid bipedalism.
A new rabbit model of implant-related biofilm infection: development and evaluation
NASA Astrophysics Data System (ADS)
Chu, Cheng-Bing; Zeng, Hong; Shen, Ding-Xia; Wang, Hui; Wang, Ji-Fang; Cui, Fu-Zhai
2016-03-01
This study is to establish a rabbit model for human prosthetic joint infection and biofilm formation. Thirty-two healthy adult rabbits were randomly divided into four groups and implanted with stainless steel screws and ultra-high molecular weight polyethylene (UHMWPE) washers in the non-articular surface of the femoral lateral condyle of the right hind knees. The rabbit knee joints were inoculated with 1 mL saline containing 0, 102, 103, 104 CFU of Staphylococcus epidermidis ( S. epidermidis) isolated from the patient with total knee arthroplasty (TKA) infection, respectively. On the 14th postoperative day, the UHMWPE washers from the optimal 103 CFU group were further examined. The SEM examination showed a typical biofilm construction that circular S. epidermidis were embedded in a mucous-like matrix. In addition, the LCSM examination showed that the biofilm consisted of the polysaccharide stained bright green fluorescence and S. epidermidis radiating red fluorescence. Thus, we successfully create a rabbit model for prosthetic joint infection and biofilm formation, which should be valuable for biofilm studies.
NASA Astrophysics Data System (ADS)
Sewell, Tanzania S.; Piacsek, Kelly L.; Heckel, Beth A.; Sabol, John M.
2011-03-01
The current imaging standard for diagnosis and monitoring of knee osteoarthritis (OA) is projection radiography. However radiographs may be insensitive to markers of early disease such as osteophytes and joint space narrowing (JSN). Relative to standard radiography, digital X-ray tomosynthesis (DTS) may provide improved visualization of the markers of knee OA without the interference of superimposed anatomy. DTS utilizes a series of low-dose projection images over an arc of +/-20 degrees to reconstruct tomographic images parallel to the detector. We propose that DTS can increase accuracy and precision in JSN quantification. The geometric accuracy of DTS was characterized by quantifying joint space width (JSW) as a function of knee flexion and position using physical and anthropomorphic phantoms. Using a commercially available digital X-ray system, projection and DTS images were acquired for a Lucite rod phantom with known gaps at various source-object-distances, and angles of flexion. Gap width, representative of JSW, was measured using a validated algorithm. Over an object-to-detector-distance range of 5-21cm, a 3.0mm gap width was reproducibly measured in the DTS images, independent of magnification. A simulated 0.50mm (+/-0.13) JSN was quantified accurately (95% CI 0.44-0.56mm) in the DTS images. Angling the rods to represent knee flexion, the minimum gap could be precisely determined from the DTS images and was independent of flexion angle. JSN quantification using DTS was insensitive to distance from patient barrier and flexion angle. Potential exists for the optimization of DTS for accurate radiographic quantification of knee OA independent of patient positioning.
2014-01-01
Background Femorotibial knee osteoarthritis is associated with muscle weakness in the lower limbs, particularly in the quadriceps, which results in disease progression. The interest of having muscular strengthening as part of the therapeutic arsenal for the medical treatment of knee osteoarthritis is now well established. The functional disability induced by knee osteoarthritis manifests itself principally when walking, notably downhill, during which the muscles are called upon to contract eccentrically. We can therefore think that eccentric muscular strengthening could bring a functional benefit that is superior to concentric muscular strengthening. Methods/Design This is a prospective, randomized, bicenter, parallel-group, international study. Eighty patients aged from 40 to 75 years old, suffering from medical-stage knee osteoarthritis, will undertake 6 weeks of isokinetic muscular strengthening. Randomization determines the mode of muscular strengthening: either exclusively eccentric or exclusively concentric. The principal objective is to demonstrate the superiority of the improvement in the quadriceps isokinetic torque after isokinetic muscular strengthening by the eccentric mode compared to the concentric mode. The following parameters are also evaluated: the variations in the level of pain, the parameters of walking (maximum speed over 10 and 200 meters, analysis on a computerized Gaitrite™ treadmill), static equilibrium (on a FUSYO™ force platform), and the functional status of the patient using the Western Ontario and MacMaster Universities osteoarthritis index (WOMAC) questionnaire after the strengthening period and at 6 months. Discussion A better knowledge of the most effective mode of muscular strengthening is needed to optimize the functional benefits to the patients. In case of superiority in terms of efficacy of the eccentric mode, the latter could be given priority in the rehabilitation treatment of knee osteoarthritis patients. Trial registration Clinical trials.gov number: NCT01586130. PMID:24693988
Jegu, Anne-Gaëlle; Pereira, Bruno; Andant, Nicolas; Coudeyre, Emmanuel
2014-04-02
Femorotibial knee osteoarthritis is associated with muscle weakness in the lower limbs, particularly in the quadriceps, which results in disease progression. The interest of having muscular strengthening as part of the therapeutic arsenal for the medical treatment of knee osteoarthritis is now well established.The functional disability induced by knee osteoarthritis manifests itself principally when walking, notably downhill, during which the muscles are called upon to contract eccentrically.We can therefore think that eccentric muscular strengthening could bring a functional benefit that is superior to concentric muscular strengthening. This is a prospective, randomized, bicenter, parallel-group, international study. Eighty patients aged from 40 to 75 years old, suffering from medical-stage knee osteoarthritis, will undertake 6 weeks of isokinetic muscular strengthening. Randomization determines the mode of muscular strengthening: either exclusively eccentric or exclusively concentric.The principal objective is to demonstrate the superiority of the improvement in the quadriceps isokinetic torque after isokinetic muscular strengthening by the eccentric mode compared to the concentric mode.The following parameters are also evaluated: the variations in the level of pain, the parameters of walking (maximum speed over 10 and 200 meters, analysis on a computerized Gaitrite™ treadmill), static equilibrium (on a FUSYO™ force platform), and the functional status of the patient using the Western Ontario and MacMaster Universities osteoarthritis index (WOMAC) questionnaire after the strengthening period and at 6 months. A better knowledge of the most effective mode of muscular strengthening is needed to optimize the functional benefits to the patients. In case of superiority in terms of efficacy of the eccentric mode, the latter could be given priority in the rehabilitation treatment of knee osteoarthritis patients. Clinical trials.gov number: NCT01586130.
Smith, William B; Steinberg, Joni; Scholtes, Stefan; Mcnamara, Iain R
2017-03-01
To compare the age-based cost-effectiveness of total knee arthroplasty (TKA), unicompartmental knee arthroplasty (UKA), and high tibial osteotomy (HTO) for the treatment of medial compartment knee osteoarthritis (MCOA). A Markov model was used to simulate theoretical cohorts of patients 40, 50, 60, and 70 years of age undergoing primary TKA, UKA, or HTO. Costs and outcomes associated with initial and subsequent interventions were estimated by following these virtual cohorts over a 10-year period. Revision and mortality rates, costs, and functional outcome data were estimated from a systematic review of the literature. Probabilistic analysis was conducted to accommodate these parameters' inherent uncertainty, and both discrete and probabilistic sensitivity analyses were utilized to assess the robustness of the model's outputs to changes in key variables. HTO was most likely to be cost-effective in cohorts under 60, and UKA most likely in those 60 and over. Probabilistic results did not indicate one intervention to be significantly more cost-effective than another. The model was exquisitely sensitive to changes in utility (functional outcome), somewhat sensitive to changes in cost, and least sensitive to changes in 10-year revision risk. HTO may be the most cost-effective option when treating MCOA in younger patients, while UKA may be preferred in older patients. Functional utility is the primary driver of the cost-effectiveness of these interventions. For the clinician, this study supports HTO as a competitive treatment option in young patient populations. It also validates each one of the three interventions considered as potentially optimal, depending heavily on patient preferences and functional utility derived over time.
Computer-aided diagnosis of early knee osteoarthritis based on MRI T2 mapping.
Wu, Yixiao; Yang, Ran; Jia, Sen; Li, Zhanjun; Zhou, Zhiyang; Lou, Ting
2014-01-01
This work was aimed at studying the method of computer-aided diagnosis of early knee OA (OA: osteoarthritis). Based on the technique of MRI (MRI: Magnetic Resonance Imaging) T2 Mapping, through computer image processing, feature extraction, calculation and analysis via constructing a classifier, an effective computer-aided diagnosis method for knee OA was created to assist doctors in their accurate, timely and convenient detection of potential risk of OA. In order to evaluate this method, a total of 1380 data from the MRI images of 46 samples of knee joints were collected. These data were then modeled through linear regression on an offline general platform by the use of the ImageJ software, and a map of the physical parameter T2 was reconstructed. After the image processing, the T2 values of ten regions in the WORMS (WORMS: Whole-organ Magnetic Resonance Imaging Score) areas of the articular cartilage were extracted to be used as the eigenvalues in data mining. Then,a RBF (RBF: Radical Basis Function) network classifier was built to classify and identify the collected data. The classifier exhibited a final identification accuracy of 75%, indicating a good result of assisting diagnosis. Since the knee OA classifier constituted by a weights-directly-determined RBF neural network didn't require any iteration, our results demonstrated that the optimal weights, appropriate center and variance could be yielded through simple procedures. Furthermore, the accuracy for both the training samples and the testing samples from the normal group could reach 100%. Finally, the classifier was superior both in time efficiency and classification performance to the frequently used classifiers based on iterative learning. Thus it was suitable to be used as an aid to computer-aided diagnosis of early knee OA.
Singh, Jasvinder A; Lewallen, David G
2014-04-11
To characterize whether medical comorbidities, depression and anxiety predict patient-reported functional improvement after total knee arthroplasty (TKA). We analyzed the prospectively collected data from the Mayo Clinic Total Joint Registry for patients who underwent primary or revision TKA between 1993-2005. Using multivariable-adjusted logistic regression analyses, we examined whether medical comorbidities, depression and anxiety were associated with patient-reported subjective improvement in knee function 2- or 5-years after primary or revision TKA. Odds ratios (OR), along with 95% confidence intervals (CI) and p-value are presented. We studied 7,139 primary TKAs at 2- and 4,234 at 5-years; and, 1,533 revision TKAs at 2-years and 881 at 5-years. In multivariable-adjusted analyses, we found that depression was associated with significantly lower odds of 0.5 (95% confidence interval [CI]: 0.3 to 0.9; p = 0.02) of 'much better' knee functional status (relative to same or worse status) 2 years after primary TKA. Higher Deyo-Charlson index was significantly associated with lower odds of 0.5 (95% CI: 0.2 to 1.0; p = 0.05) of 'much better' knee functional status after revision TKA for every 5-point increase in score. Depression in primary TKA and higher medical comorbidity in revision TKA cohorts were associated with suboptimal improvement in index knee function. It remains to be seen whether strategies focused at optimization of medical comorbidities and depression pre- and peri-operatively may help to improve TKA outcomes. Study limitations include non-response bias and the use of diagnostic codes, which may be associated with under-diagnosis of conditions.
Lim, Gye-Yeon; Im, Soo Ah; Jung, Won Sang; Lee, Jae Mun; Lee, Ah Won
2005-09-01
The aim of this prospective study was to evaluate the diagnostic value of power Doppler ultrasonography (PDUS) and contrast-enhanced PDUS (CEPDUS) in the depiction and characterization of experimentally induced arthritis in the rabbit. Thirty rabbits were divided into three groups consisting of one control group (saline injection group) and two experimental groups: a suppurative arthritis group and a chemically induced synovitis group. The same amount (1 ml) of each agent was directly injected into the right hip joint. Serial color Doppler ultrasound (CDUS), PDUS, and CEPDUS images were obtained before and after injection. We observed that all of the infected knees in the suppurative arthritis group with Staphylococcus aureus demonstrated an increased signal on PDUS after inoculation. A minimal power Doppler signal was presented in the chemically induced synovitis group with talc injection, but none of the control knees demonstrated any increased signals. CEPDUS was the most sensitive imaging modality for evaluating the increase of blood flows in suppurative arthritis and was subsequently followed by PDUS and CDUS. The increased signals obtained with PDUS represent increased local blood flows; therefore, this technique can be used for evaluating the degree of inflammation. Furthermore, using the contrast agent enhances the sensitivity of PDUS, and it can even be useful for differentiating borderline cases. Copyright 2005 Wiley Periodicals, Inc
Ferket, Bart S; Feldman, Zachary; Zhou, Jing; Oei, Edwin H; Bierma-Zeinstra, Sita M A; Mazumdar, Madhu
2017-03-28
Objectives To evaluate the impact of total knee replacement on quality of life in people with knee osteoarthritis and to estimate associated differences in lifetime costs and quality adjusted life years (QALYs) according to use by level of symptoms. Design Marginal structural modeling and cost effectiveness analysis based on lifetime predictions for total knee replacement and death from population based cohort data. Setting Data from two studies-Osteoarthritis Initiative (OAI) and the Multicenter Osteoarthritis Study (MOST)-within the US health system. Participants 4498 participants with or at high risk for knee osteoarthritis aged 45-79 from the OAI with no previous knee replacement (confirmed by baseline radiography) followed up for nine years. Validation cohort comprised 2907 patients from MOST with two year follow-up. Intervention Scenarios ranging from current practice, defined as total knee replacement practice as performed in the OAI (with procedural rates estimated by a prediction model), to practice limited to patients with severe symptoms to no surgery. Main outcome measures Generic (SF-12) and osteoarthritis specific quality of life measured over 96 months, model based QALYs, costs, and incremental cost effectiveness ratios over a lifetime horizon. Results In the OAI, total knee replacement showed improvements in quality of life with small absolute changes when averaged across levels of confounding variables: 1.70 (95% uncertainty interval 0.26 to 3.57) for SF-12 physical component summary (PCS); -10.69 (-13.39 to -8.01) for Western Ontario and McMaster Universities arthritis index (WOMAC); and 9.16 (6.35 to 12.49) for knee injury and osteoarthritis outcome score (KOOS) quality of life subscale. These improvements became larger with decreasing functional status at baseline. Provision of total knee replacement to patients with SF-12 PCS scores <35 was the optimal scenario given a cost effectiveness threshold of $200 000/QALY, with cost savings of $6974 ($5789 to $8269) and a minimal loss of 0.008 (-0.056 to 0.043) QALYs compared with current practice. These findings were reproduced among patients with knee osteoarthritis from the MOST cohort and were robust against various scenarios including increased rates of total knee replacement and mortality and inclusion of non-healthcare costs but were sensitive to increased deterioration in quality of life without surgery. In a threshold analysis, total knee replacement would become cost effective in patients with SF-12 PCS scores ≤40 if the associated hospital admission costs fell below $14 000 given a cost effectiveness threshold of $200 000/QALY. Conclusion Current practice of total knee replacement as performed in a recent US cohort of patients with knee osteoarthritis had minimal effects on quality of life and QALYs at the group level. If the procedure were restricted to more severely affected patients, its effectiveness would rise, with practice becoming economically more attractive than its current use. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Razii, Nima; Abbas, Ammar M I; Kakar, Rahul; Agarwal, Sanjeev; Morgan-Jones, Rhidian
2016-12-01
Periprosthetic infection following total knee arthroplasty is a devastating complication, which is not always satisfactorily resolved by revision surgery. Arthrodesis is a salvage alternative to above-knee amputation or permanent resection arthroplasty. Fixation options include internal compression plating, external fixation, and intramedullary nails. We retrospectively reviewed twelve consecutive cases (9 males, 3 females; mean age, 67 years) of knee arthrodesis with a long intramedullary nail, performed at a single institution between 2003 and 2014. Desired outcomes were the ability to mobilize without pain, solid radiographic fusion, and the eradication of infection. Mean follow-up was 48.5 months (range, 9-120 months). Eleven patients (92 %) demonstrated stable fusion, ten patients (83 %) were ambulatory without pain, and ten patients (83 %) remained without infection at most recent follow-up. Eight patients (67 %) achieved union at an average of 12 months; three required repeat procedures, achieving union at an average of 9 months. There was a significant difference (P < 0.01) between the numbers of previous operations amongst the eight patients who initially achieved union (mean, 3.25) and three who subsequently required repeat procedures (mean, 8.33). In contrast to similar studies, we performed a single-stage exchange where possible, while comparable ambulatory and fusion rates were observed. Numerous previous attempts at revision arthroplasty, co-morbidities, and infections with highly resistant organisms have been associated with further complications. Although technically challenging, knee arthrodesis with a long intramedullary nail offers an acceptable limb salvage procedure for carefully selected patients with complex periprosthetic infections.
Xie, F; Li, S-C; Fong, K-Y; Lo, N-N; Yeo, S-J; Yang, K-Y; Thumboo, J
2006-03-01
To determine important health-related quality of life (HRQoL) domains and items within each domain affected by knee osteoarthritis (OA), identify ethnic variations in the importance of these domains and items among three ethnic groups, and determine how identified domains and items mapped onto selected OA-specific HRQoL instruments. Focus groups were conducted among subjects with knee OA stratified by gender, ethnicity, and language spoken. All focus groups were audio-taped and transcribed verbatim, with subsequent translation into English for groups conducted in other languages. Data analysis was performed by combining the key elements of grounded theory and content analysis with the assistance of the qualitative software ATLAS/ti 5.0. Five domains (pain, physical disability, other symptoms of OA, mental health, and social health) were identified from the 74 items reported as important by at least one subject. These domains were important for subjects from all ethnic groups with the exception of social health, which was more often important for Malay subjects. Items more commonly reported as important in the pain, physical disability, and other symptoms of OA domains were generally similar across ethnic groups. In contrast, important items in the mental and social health domains differed among ethnic groups. The impact of knee OA on HRQoL is broadly similar in both Asian and Western socio-cultural contexts. Both similarities and differences in important domains and items were identified among subjects with knee OA from three major Asian ethnic groups.
Muhle, Claus; Ahn, Joong Mo; Trudell, Debra; Resnick, Donald
2008-06-01
The purpose of the study was to define magnetic resonance imaging (MRI) findings before and after contrast medium opacification of the knee joint in cadaveric specimens to demonstrate anatomical landmarks of the trochlear surface in relation to the neighboring structures, and to evaluate different MRI sequences in the detection of cartilage defects of the trochlear and patellar surface of the knee. The morphology and relationship of the proximal trochlear surface to the prefemoral fat of the distal femur were investigated by use of different MR sequences before and after intra-articular gadolinium administration into the knee joint in ten cadaveric knees. Anatomic sections were subsequently obtained. In addition, evaluation of the articular surface of the trochlea was performed by two independent observers. The cartilage surfaces were graded using a 2-point system, and results were compared with macroscopic findings. Of 40 cartilage surfaces evaluated, histopathologic findings showed 9 normal surfaces, 20 containing partial-thickness defects, and 11 containing full-thickness defects. Compared with macroscopic data, sensitivity of MR sequences for the two reviewers was between 17 and 90%; specificity, 75 and 100%; positive predictive value, 75 and 100%; negative predictive value, 20 and 100%, depending on patellar or trochlea lesions. Interobserver variability for the presence of disease, which was measured using the kappa statistic, was dependent on the MR sequence used between 0.243 and 0.851. Magnetic resonance imaging sequences can be used to evaluate the cartilage of the trochlear surface with less accuracy when compared with the results of grading the articular cartilage of the patella.
Beckmann, J; Steinert, A; Zilkens, C; Zeh, A; Schnurr, C; Schmitt-Sody, M; Gebauer, M
2016-04-01
Knee arthroplasty is a successful standard procedure in orthopedic surgery; however, approximately 20 % of patients are dissatisfied with the clinical results as they suffer pain and can no longer achieve the presurgery level of activity. According to the literature the reasons are inexact fitting of the prosthesis or too few anatomically formed implants resulting in less physiological kinematics of the knee joint. Reducing the number of dissatisfied patients and the corresponding number of revisions is an important goal considering the increasing need for artificial joints. In this context, patient-specific knee implants are an obvious alternative to conventional implants. For the first time implants are now matched to the individual bone and not vice versa to achieve the best possible individual situation and geometry and more structures (e.g. ligaments and bone) are preserved or only those structures are replaced which were actually destroyed by arthrosis. According to the authors view, this represents an optimal and pioneering addition to conventional implants. Patient-specific implants and the instruments needed for correct alignment and fitting can be manufactured by virtual 3D reconstruction and 3D printing based on computed tomography (CT) scans. The portfolio covers medial as well as lateral unicondylar implants, medial as well as lateral bicompartmental implants (femorotibial and patellofemoral compartments) and cruciate ligament-preserving as well as cruciate ligament-substituting total knee replacements; however, it must be explicitly emphasized that the literature is sparse and no long-term data are available.
Patellar tendon load in different types of eccentric squats.
Frohm, A; Halvorsen, K; Thorstensson, A
2007-07-01
Differences in mechanical loading of the patellar tendon have been suggested as a reason for varying effects in rehabilitation of patellar tendinopathy using different eccentric squat exercises and devices. The aim was to characterize the magnitude and pattern of mechanical load at the knee and on the patellar tendon during four types of eccentric squat. Subjects performed squats with a submaximal free weight and with maximal effort in a device for eccentric overloading (Bromsman), on a decline board and horizontal surface. Kinematics was recorded with a motion-capture system, reaction forces with force plates, and electromyography from three leg muscles with surface electrodes. Inverse dynamics was used to calculate knee joint kinetics. Eccentric work, mean and peak patellar tendon force, and angle at peak force were greater (25-30%) for squats on decline board compared to horizontal surface with free weight, but not in Bromsman. Higher knee load forces (60-80%), but not work, were observed with Bromsman than free weight. Angular excursions at the knee and ankle were larger with decline board, particularly with free weight, and smaller in Bromsman than with free weight. Mean electromyography was greater on a decline board for gastrocnemius (13%) and vastus medialis (6%) with free weight, but in Bromsman only for gastrocnemius (7%). The results demonstrated clear differences in the biomechanical loading on the knee during different squat exercises. Quantification of such differences provides information that could be used to explain differences in rehabilitation effects as well as in designing more optimal rehabilitation exercises for patellar tendinopathy.
Immediate effects of whole body vibration on patellar tendon properties and knee extension torque.
Rieder, F; Wiesinger, H-P; Kösters, A; Müller, E; Seynnes, O R
2016-03-01
Reports about the immediate effects of whole body vibration (WBV) exposure upon torque production capacity are inconsistent. However, the changes in the torque-angle relationship observed by some authors after WBV may hinder the measurement of torque changes at a given angle. Acute changes in tendon mechanical properties do occur after certain types of exercise but this hypothesis has never been tested after a bout of WBV. The purpose of the present study was to investigate whether tendon compliance is altered immediately after WBV, effectively shifting the optimal angle of peak torque towards longer muscle length. Twenty-eight subjects were randomly assigned to either a WBV (n = 14) or a squatting control group (n = 14). Patellar tendon CSA, stiffness and Young's modulus and knee extension torque-angle relationship were measured using ultrasonography and dynamometry 1 day before and directly after the intervention. Tendon CSA was additionally measured 24 h after the intervention to check for possible delayed onset of swelling. The vibration intervention had no effects on patellar tendon CSA, stiffness and Young's modulus or the torque-angle relationship. Peak torque was produced at ~70° knee angle in both groups at pre- and post-test. Additionally, the knee extension torque globally remained unaffected with the exception of a small (-6%) reduction in isometric torque at a joint angle of 60°. The present results indicate that a single bout of vibration exposure does not substantially alter patellar tendon properties or the torque-angle relationship of knee extensors.
Desmoid tumor of posterior cruciate ligament of the knee: a case report
2013-01-01
Background Desmoid tumor is a rare type of cancer that develops in the tissues that form tendons and ligaments. These tumors, also called aggressive fibromatosis, are considered benign with no metastatic potential. They may invade nearby tissues and organs, however, and can be difficult to control. Desmoid tumor in the posterior cruciate ligament (PCL) of the knee has never been described in the literature. Case presentation A 49-year-old man presented with a 2-month history of posteromedial knee dull pain and decreased range of motion of the knee. He was diagnosed desmoid tumor of posterior cruciate ligament of the knee by intraoperative biopsy, and underwent successful PCL resection and reconstruction by Four-strand semitendinosus and gracilis tendon autograft arthroscopically, and fortunately five years after operation, there were no clues as to recurrence of the tumor examined by Magnetic Resonance Imaging (MRI). Conclusion Desmoid tumor is characterized by infiltrative growth and a tendency towards recurrence,as this tumor entity is rare, data giving evidence based recommendations for the optimal treatment algorithm for this disease is lacking. At present there is no definite and effective method of treatment. However, early detection of the tumor play an important role, MRI is now the most important method for the detection of tumor extent, which facilitates the treatment choice as well as the prediction of prognosis. In our case, we followed-up the patient five years postoperatively by MRI and got a good result. PMID:23432794
Kerkum, Yvette L.; Buizer, Annemieke I.; van den Noort, Josien C.; Becher, Jules G.; Harlaar, Jaap; Brehm, Merel-Anne
2015-01-01
Introduction Rigid Ankle-Foot Orthoses (AFOs) are commonly prescribed to counteract excessive knee flexion during the stance phase of gait in children with cerebral palsy (CP). While rigid AFOs may normalize knee kinematics and kinetics effectively, it has the disadvantage of impeding push-off power. A spring-like AFO may enhance push-off power, which may come at the cost of reducing the knee flexion less effectively. Optimizing this trade-off between enhancing push-off power and normalizing knee flexion in stance is expected to maximize gait efficiency. This study investigated the effects of varying AFO stiffness on gait biomechanics and efficiency in children with CP who walk with excessive knee flexion in stance. Fifteen children with spastic CP (11 boys, 10±2 years) were prescribed with a ventral shell spring-hinged AFO (vAFO). The hinge was set into a rigid, or spring-like setting, using both a stiff and flexible performance. At baseline (i.e. shoes-only) and for each vAFO, a 3D-gait analysis and 6-minute walk test with breath-gas analysis were performed at comfortable speed. Lower limb joint kinematics and kinetics were calculated. From the 6-minute walk test, walking speed and the net energy cost were determined. A generalized estimation equation (p<0.05) was used to analyze the effects of different conditions. Compared to shoes-only, all vAFOs improved the knee angle and net moment similarly. Ankle power generation and work were preserved only by the spring-like vAFOs. All vAFOs decreased the net energy cost compared to shoes-only, but no differences were found between vAFOs, showing that the effects of spring-like vAFOs to promote push-off power did not lead to greater reductions in walking energy cost. These findings suggest that, in this specific group of children with spastic CP, the vAFO stiffness that maximizes gait efficiency is primarily determined by its effect on knee kinematics and kinetics rather than by its effect on push-off power. Trial Registration Dutch Trial Register NTR3418 PMID:26600039
Kerkum, Yvette L; Buizer, Annemieke I; van den Noort, Josien C; Becher, Jules G; Harlaar, Jaap; Brehm, Merel-Anne
2015-01-01
Rigid Ankle-Foot Orthoses (AFOs) are commonly prescribed to counteract excessive knee flexion during the stance phase of gait in children with cerebral palsy (CP). While rigid AFOs may normalize knee kinematics and kinetics effectively, it has the disadvantage of impeding push-off power. A spring-like AFO may enhance push-off power, which may come at the cost of reducing the knee flexion less effectively. Optimizing this trade-off between enhancing push-off power and normalizing knee flexion in stance is expected to maximize gait efficiency. This study investigated the effects of varying AFO stiffness on gait biomechanics and efficiency in children with CP who walk with excessive knee flexion in stance. Fifteen children with spastic CP (11 boys, 10±2 years) were prescribed with a ventral shell spring-hinged AFO (vAFO). The hinge was set into a rigid, or spring-like setting, using both a stiff and flexible performance. At baseline (i.e. shoes-only) and for each vAFO, a 3D-gait analysis and 6-minute walk test with breath-gas analysis were performed at comfortable speed. Lower limb joint kinematics and kinetics were calculated. From the 6-minute walk test, walking speed and the net energy cost were determined. A generalized estimation equation (p<0.05) was used to analyze the effects of different conditions. Compared to shoes-only, all vAFOs improved the knee angle and net moment similarly. Ankle power generation and work were preserved only by the spring-like vAFOs. All vAFOs decreased the net energy cost compared to shoes-only, but no differences were found between vAFOs, showing that the effects of spring-like vAFOs to promote push-off power did not lead to greater reductions in walking energy cost. These findings suggest that, in this specific group of children with spastic CP, the vAFO stiffness that maximizes gait efficiency is primarily determined by its effect on knee kinematics and kinetics rather than by its effect on push-off power. Dutch Trial Register NTR3418.
2017-01-01
Purpose Clinical test batteries for evaluation of knee function after injury to the Anterior Cruciate Ligament (ACL) should be valid and feasible, while reliably capturing the outcome of rehabilitation. There is currently a lack of consensus as to which of the many available assessment tools for knee function that should be included. The present aim was to use a statistical approach to investigate the contribution of frequently used tests to avoid redundancy, and filter them down to a proposed comprehensive and yet feasible test battery for long-term evaluation after ACL injury. Methods In total 48 outcome variables related to knee function, all potentially relevant for a long-term follow-up, were included from a cross-sectional study where 70 ACL-injured (17–28 years post injury) individuals were compared to 33 controls. Cluster analysis and logistic regression were used to group variables and identify an optimal test battery, from which a summarized estimator of knee function representing various functional aspects was derived. Results As expected, several variables were strongly correlated, and the variables also fell into logical clusters with higher within-correlation (max ρ = 0.61) than between clusters (max ρ = 0.19). An extracted test battery with just four variables assessing one-leg balance, isokinetic knee extension strength and hop performance (one-leg hop, side hop) were mathematically combined to an estimator of knee function, which acceptably classified ACL-injured individuals and controls. This estimator, derived from objective measures, correlated significantly with self-reported function, e.g. Lysholm score (ρ = 0.66; p<0.001). Conclusions The proposed test battery, based on a solid statistical approach, includes assessments which are all clinically feasible, while also covering complementary aspects of knee function. Similar test batteries could be determined for earlier phases of ACL rehabilitation or to enable longitudinal monitoring. Such developments, established on a well-grounded consensus of measurements, would facilitate comparisons of studies and enable evidence-based rehabilitation. PMID:28459885
Valiyaveettil, Manojkumar; Mort, John S; McDevitt, Cahir A
2005-01-01
The concentration, spatial distribution, and gene expression of aggrecan in meniscus, articular cartilage, and the anterior and posterior cruciate ligaments (ACL and PCL) was determined in the knee joints of five mature dogs. An anti-serum against peptide sequences specific to the G1 domain of aggrecan was employed in competitive-inhibition ELISA of guanidine HCl extracts and immunofluorescence microscopy. Gene expression was determined by Taqman real-time PCR. The concentration of aggrecan in articular cartilage (240.1 +/- 32 nMol/g dry weight) was higher than that in meniscus (medial meniscus: 33.4 +/- 4.3 nMol/g) and ligaments (ACL: 6.8 +/- 0.9 nMol/g). Aggrecan was more concentrated in the inner than the outer zone of the meniscus. Aggrecan in meniscus showed an organized, spatial network, in contrast to its diffuse distribution in articular cartilage. Thus, differences in the concentration, gene expression, and spatial distribution of aggrecan constitute another molecular distinction between hyaline cartilage and fibrocartilage of the knee.
Le Graverand, M-P H; Mazzuca, S; Lassere, M; Guermazi, A; Pickering, E; Brandt, K; Peterfy, C; Cline, G; Nevitt, M; Woodworth, T; Conaghan, P; Vignon, E
2006-01-01
Recent studies using various standardized radiographic acquisition techniques have demonstrated the necessity of reproducible radioanatomic alignment of the knee to assure precise measurements of medial tibiofemoral joint space width (JSW). The objective of the present study was to characterize the longitudinal performance of several acquisition techniques with respect to long-term reproducibility of positioning of the knee, and the impact of changes in positioning on the rate and variability of joint space narrowing (JSN). Eighty subjects were randomly selected from each of three cohorts followed in recent studies of the radiographic progression of knee osteoarthritis (OA): the Health ABC study (paired fixed-flexion [FF] radiographs taken at a 36-month interval); the Glucosamine Arthritis Intervention Trial (GAIT) (paired metatarsophalangeal [MTP] radiographs obtained at a 12-month interval), and a randomized clinical trial of doxycycline (fluoroscopically assisted semiflexed anteroposterior (AP) radiographs taken at a 16-month interval). Manual measurements were obtained from each radiograph to represent markers of radioanatomic positioning of the knee (alignment of the medial tibial plateau and X-ray beam, knee rotation, femorotibial angle) and to evaluate minimum JSW (mJSW) in the medial tibiofemoral compartment. The effects on the mean annualized rate of JSN and on the variability of that rate of highly reproduced vs variable positioning of the knee in serial radiographs were evaluated. Parallel or near-parallel alignment was achieved significantly more frequently with the fluoroscopically guided positioning used in the semiflexed AP protocol than with either the non-fluoroscopic FF or MTP protocol (68% vs 14% for both FF and MTP protocols when measured at the midpoint of the medial compartment; 75% vs 26% and 34% for the FF and MTP protocols, respectively, when measured at the site of mJSW; P<0.001 for each). Knee rotation was reproduced more frequently in semiflexed AP radiographs than in FF radiographs (66% vs 45%, P<0.01). In contrast, the FF technique yielded a greater proportion of paired radiographs in which the femorotibial angle was accurately reproduced than the semiflexed AP or MTP protocol (78% vs 59% and 56%, respectively, P<0.01 for each). Notably, only paired radiographs with parallel or near-parallel alignment exhibited a mean rate of JSN (+/-SD) in the OA knee that was more rapid and less variable than that measured in all knees (0.186+/-0.274 mm/year, standardized response to mean [SRM]=0.68 vs 0.128+/-0.291 mm/year, SRM=0.44). This study confirms the importance of parallel radioanatomic alignment of the anterior and posterior margins of the medial tibial plateau in detecting JSN in subjects with knee OA. The use of radiographic methods that assure parallel alignment during serial X-ray examinations will permit the design of more efficient studies of biomarkers of OA progression and of structure modification in knee OA.
Xing, Fei; Lu, Bin; Kuang, Ming-Jie; Wang, Ying; Zhao, Yun-Long; Zhao, Jie; Sun, Lei; Wang, Yan; Ma, Jian-Xiong; Ma, Xin-Long
2017-06-01
The aim of this study was to evaluate the immediate effects of lateral wedge arch support insoles (LWAS) on reducing the knee joint load in patients with medial knee osteoarthritis (OA) compared with an appropriate control. Databases including Medline, EMBASE, Web of Science, Wiley Online Library, Cochrane library, and Google Scholar were searched with no limits on study date or language, from the earliest available date to October 31, 2016. The included studies had to have the aim of reducing knee load and have an appropriate control. The main measured values were the first and second peak external knee adduction moments (EKAM) and the knee adduction angular impulse (KAAI). The random-effects model was used for analyzing the eligible studies. Nine studies met the inclusion criteria with a total of 356 participants of whom 337 received LWAS treatment. The risk of methodological bias scores (quality index) ranged from 21 to 27 of 32. Treatment with LWAS resulted in statistically significant reductions in the first peak EKAM (P = .005), the second peak EKAM (P = .01), and the KAAI (P = .03). However, among trials in which the control treatment was control shoes, the LWAS showed no associations on the first peak EKAM (P = .10) or the KAAI (P = .06); among trials in which the control treatment was neutral insoles, the LWAS showed no associations on the second peak EKAM (P = .21) or the KAAI (P = .23). At the same time, the LWAS showed no statistically significant reduction on the first peak EKAM (P = .39) when compared with flat insoles. Although meta-analysis outcomes of all studies indicated statistically significant associations between LWAS and reductions of the first peak EKAM, second peak EKAM and KAAI in people with medial knee OA while walking, different results existed in subgroups using various control conditions for comparison. These findings do not support the use of LWAS insoles for reducing knee load. An optimal LWAS treatment should provide the appropriate height of arch support and amount of lateral wedging. Further research should investigate the best combination of these 2 parameters to achieve efficacy without altered comfort.
Xing, Fei; Lu, Bin; Kuang, Ming-jie; Wang, Ying; Zhao, Yun-long; Zhao, Jie; Sun, Lei; Wang, Yan; Ma, Jian-xiong; Ma, Xin-long
2017-01-01
Abstract Objective: The aim of this study was to evaluate the immediate effects of lateral wedge arch support insoles (LWAS) on reducing the knee joint load in patients with medial knee osteoarthritis (OA) compared with an appropriate control. Methods: Databases including Medline, EMBASE, Web of Science, Wiley Online Library, Cochrane library, and Google Scholar were searched with no limits on study date or language, from the earliest available date to October 31, 2016. The included studies had to have the aim of reducing knee load and have an appropriate control. The main measured values were the first and second peak external knee adduction moments (EKAM) and the knee adduction angular impulse (KAAI). The random-effects model was used for analyzing the eligible studies. Results: Nine studies met the inclusion criteria with a total of 356 participants of whom 337 received LWAS treatment. The risk of methodological bias scores (quality index) ranged from 21 to 27 of 32. Treatment with LWAS resulted in statistically significant reductions in the first peak EKAM (P = .005), the second peak EKAM (P = .01), and the KAAI (P = .03). However, among trials in which the control treatment was control shoes, the LWAS showed no associations on the first peak EKAM (P = .10) or the KAAI (P = .06); among trials in which the control treatment was neutral insoles, the LWAS showed no associations on the second peak EKAM (P = .21) or the KAAI (P = .23). At the same time, the LWAS showed no statistically significant reduction on the first peak EKAM (P = .39) when compared with flat insoles. Conclusion: Although meta-analysis outcomes of all studies indicated statistically significant associations between LWAS and reductions of the first peak EKAM, second peak EKAM and KAAI in people with medial knee OA while walking, different results existed in subgroups using various control conditions for comparison. These findings do not support the use of LWAS insoles for reducing knee load. An optimal LWAS treatment should provide the appropriate height of arch support and amount of lateral wedging. Further research should investigate the best combination of these 2 parameters to achieve efficacy without altered comfort. PMID:28614253
Lorbach, Olaf; Zumbansen, Nikolaus; Kieb, Matthias; Efe, Turgay; Pizanis, Antonius; Kohn, Dieter; Haupert, Alexander
2018-04-01
Objective evaluation of the optimal graft tension angle to fully restore patellofemoral contact pressure in reconstruction of the medial patellofemoral ligament (MPFL) in comparison to the native knee. Twelve cadaveric knee specimens were fixed in a custom-made fixation device. A sensitive pressure film (Tekscan) was fixed in the patellofemoral joint, and patellofemoral contact pressure was assessed during a dynamic flexion movement from 0° to 90°. The MPFL was cut and measurements were repeated. Reconstruction of the MPFL was performed with the gracilis tendon subsequently fixed in the femur at 15°, 30°, 45°, 60°, 75°, and 90° of knee flexion under controlled tension (2 N). The sequence of the flexion angles was alternated. Pressure measurements were repeated after every fixation of the graft. No significant differences were seen in the overall patellofemoral contact pressure compared to the native knee (P > .05). However, medial patellofemoral pressure showed a significant increased patellofemoral contact pressure after MPFL reconstruction at a knee flexion angle during graft fixation of 15° (P = .027), 45° (P = .050, P = .044), and 75° (P = .039). Moreover, proximal/distal patellofemoral contact pressure revealed a significantly reduced contact pressure at 15° (P = .003), 30° (P = .009), 45° (P = .025), 75° (P = .021), and 90° (P = .022) of flexion distal after MPFL reconstruction compared with the intact knee. Lateral patellofemoral contact pressure was significantly reduced in all performed reconstructions (P < .05). The flexion angle during graft fixation for MPFL reconstruction did not have a significant impact on the overall patellofemoral contact pressure. However, selective medial, proximal, distal, and lateral patellofemoral contact pressure was significantly altered for all reconstructions. Fixation of the MPFL graft at 60° of flexion was able to most closely restore patellofemoral contact pressure compared with the intact knee. Based on the findings of the present study, fixation of the graft in anatomic reconstruction of the MPFL should be considered in 60° of flexion under low tension (2 N) to most closely restore patellofemoral contact pressure compared with the native knee. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Yang, Liqing; Sun, Yuefeng; Li, Ge
2018-06-14
Optimal surgical approach for tibial shaft fractures remains controversial. We perform a meta-analysis from randomized controlled trials (RCTs) to compare the clinical efficacy and prognosis between infrapatellar and suprapatellar intramedullary nail in the treatment of tibial shaft fractures. PubMed, OVID, Embase, ScienceDirect, and Web of Science were searched up to December 2017 for comparative RCTs involving infrapatellar and suprapatellar intramedullary nail in the treatment of tibial shaft fractures. Primary outcomes were blood loss, visual analog scale (VAS) score, range of motion, Lysholm knee scores, and fluoroscopy times. Secondary outcomes were length of hospital stay and postoperative complications. We assessed statistical heterogeneity for each outcome with the use of a standard χ 2 test and the I 2 statistic. The meta-analysis was undertaken using Stata 14.0. Four RCTs involving 293 participants were included in our study. The present meta-analysis indicated that there were significant differences between infrapatellar and suprapatellar intramedullary nail regarding the total blood loss, VAS scores, Lysholm knee scores, and fluoroscopy times. Suprapatellar intramedullary nailing could significantly reduce total blood loss, postoperative knee pain, and fluoroscopy times compared to infrapatellar approach. Additionally, it was associated with an improved Lysholm knee scores. High-quality RCTs were still required for further investigation.
Magnetic Capture of a Molecular Biomarker from Synovial Fluid in a Rat Model of Knee Osteoarthritis
Yarmola, Elena G.; Shah, Yash; Arnold, David P.; Dobson, Jon; Allen, Kyle D.
2015-01-01
Biomarker development for osteoarthritis (OA) often begins in rodent models, but can be limited by an inability to aspirate synovial fluid from a rodent stifle (similar to the human knee). To address this limitation, we have developed a magnetic nanoparticle-based technology to collect biomarkers from a rodent stifle, termed magnetic capture. Using a common OA biomarker - the c-terminus telopeptide of type II collagen (CTXII) - magnetic capture was optimized in vitro using bovine synovial fluid and then tested in a rat model of knee OA. Anti-CTXII antibodies were conjugated to the surface of superparamagnetic iron oxide-containing polymeric particles. Using these anti-CTXII particles, magnetic capture was able to estimate the level of CTXII in 25 µL aliquots of bovine synovial fluid; and under controlled conditions, this estimate was unaffected by synovial fluid viscosity. Following in vitro testing, anti-CTXII particles were tested in a rat monoiodoacetate model of knee OA. CTXII could be magnetically captured from a rodent stifle without the need to aspirate fluid and showed 10 fold changes in CTXII levels from OA-affected joints relative to contralateral control joints. Combined, these data demonstrate the ability and sensitivity of magnetic capture for post-mortem analysis of OA biomarkers in the rat. PMID:26136062
Magnetic Capture of a Molecular Biomarker from Synovial Fluid in a Rat Model of Knee Osteoarthritis.
Yarmola, Elena G; Shah, Yash; Arnold, David P; Dobson, Jon; Allen, Kyle D
2016-04-01
Biomarker development for osteoarthritis (OA) often begins in rodent models, but can be limited by an inability to aspirate synovial fluid from a rodent stifle (similar to the human knee). To address this limitation, we have developed a magnetic nanoparticle-based technology to collect biomarkers from a rodent stifle, termed magnetic capture. Using a common OA biomarker--the c-terminus telopeptide of type II collagen (CTXII)--magnetic capture was optimized in vitro using bovine synovial fluid and then tested in a rat model of knee OA. Anti-CTXII antibodies were conjugated to the surface of superparamagnetic iron oxide-containing polymeric particles. Using these anti-CTXII particles, magnetic capture was able to estimate the level of CTXII in 25 μL aliquots of bovine synovial fluid; and under controlled conditions, this estimate was unaffected by synovial fluid viscosity. Following in vitro testing, anti-CTXII particles were tested in a rat monoiodoacetate model of knee OA. CTXII could be magnetically captured from a rodent stifle without the need to aspirate fluid and showed tenfold changes in CTXII levels from OA-affected joints relative to contralateral control joints. Combined, these data demonstrate the ability and sensitivity of magnetic capture for post-mortem analysis of OA biomarkers in the rat.
Design of a biologically inspired lower limb exoskeleton for human gait rehabilitation.
Lyu, Mingxing; Chen, Weihai; Ding, Xilun; Wang, Jianhua; Bai, Shaoping; Ren, Huichao
2016-10-01
This paper proposes a novel bionic model of the human leg according to the theory of physiology. Based on this model, we present a biologically inspired 3-degree of freedom (DOF) lower limb exoskeleton for human gait rehabilitation, showing that the lower limb exoskeleton is fully compatible with the human knee joint. The exoskeleton has a hybrid serial-parallel kinematic structure consisting of a 1-DOF hip joint module and a 2-DOF knee joint module in the sagittal plane. A planar 2-DOF parallel mechanism is introduced in the design to fully accommodate the motion of the human knee joint, which features not only rotation but also relative sliding. Therefore, the design is consistent with the requirements of bionics. The forward and inverse kinematic analysis is studied and the workspace of the exoskeleton is analyzed. The structural parameters are optimized to obtain a larger workspace. The results using MATLAB-ADAMS co-simulation are shown in this paper to demonstrate the feasibility of our design. A prototype of the exoskeleton is also developed and an experiment performed to verify the kinematic analysis. Compared with existing lower limb exoskeletons, the designed mechanism has a large workspace, while allowing knee joint rotation and small amount of sliding.
Design of a biologically inspired lower limb exoskeleton for human gait rehabilitation
NASA Astrophysics Data System (ADS)
Lyu, Mingxing; Chen, Weihai; Ding, Xilun; Wang, Jianhua; Bai, Shaoping; Ren, Huichao
2016-10-01
This paper proposes a novel bionic model of the human leg according to the theory of physiology. Based on this model, we present a biologically inspired 3-degree of freedom (DOF) lower limb exoskeleton for human gait rehabilitation, showing that the lower limb exoskeleton is fully compatible with the human knee joint. The exoskeleton has a hybrid serial-parallel kinematic structure consisting of a 1-DOF hip joint module and a 2-DOF knee joint module in the sagittal plane. A planar 2-DOF parallel mechanism is introduced in the design to fully accommodate the motion of the human knee joint, which features not only rotation but also relative sliding. Therefore, the design is consistent with the requirements of bionics. The forward and inverse kinematic analysis is studied and the workspace of the exoskeleton is analyzed. The structural parameters are optimized to obtain a larger workspace. The results using MATLAB-ADAMS co-simulation are shown in this paper to demonstrate the feasibility of our design. A prototype of the exoskeleton is also developed and an experiment performed to verify the kinematic analysis. Compared with existing lower limb exoskeletons, the designed mechanism has a large workspace, while allowing knee joint rotation and small amount of sliding.
Ong, Carmichael F; Hicks, Jennifer L; Delp, Scott L
2016-05-01
Technologies that augment human performance are the focus of intensive research and development, driven by advances in wearable robotic systems. Success has been limited by the challenge of understanding human-robot interaction. To address this challenge, we developed an optimization framework to synthesize a realistic human standing long jump and used the framework to explore how simulated wearable robotic devices might enhance jump performance. A planar, five-segment, seven-degree-of-freedom model with physiological torque actuators, which have variable torque capacity depending on joint position and velocity, was used to represent human musculoskeletal dynamics. An active augmentation device was modeled as a torque actuator that could apply a single pulse of up to 100 Nm of extension torque. A passive design was modeled as rotational springs about each lower limb joint. Dynamic optimization searched for physiological and device actuation patterns to maximize jump distance. Optimization of the nominal case yielded a 2.27 m jump that captured salient kinematic and kinetic features of human jumps. When the active device was added to the ankle, knee, or hip, jump distance increased to between 2.49 and 2.52 m. Active augmentation of all three joints increased the jump distance to 3.10 m. The passive design increased jump distance to 3.32 m by adding torques of 135, 365, and 297 Nm to the ankle, knee, and hip, respectively. Dynamic optimization can be used to simulate a standing long jump and investigate human-robot interaction. Simulation can aid in the design of performance-enhancing technologies.
Performance characteristics of long-track speed skaters: a literature review.
Konings, Marco J; Elferink-Gemser, Marije T; Stoter, Inge K; van der Meer, Dirk; Otten, Egbert; Hettinga, Florentina J
2015-04-01
Speed skating is an intriguing sport to study from different perspectives due to the peculiar way of motion and the multiple determinants for performance. This review aimed to identify what is known on (long-track) speed skating, and which individual characteristics determine speed skating performance. A total of 49 studies were included. Based on a multidimensional performance model, person-related performance characteristics were categorized in anthropometrical, technical, physiological, tactical, and psychological characteristics. Literature was found on anthropometry, technique, physiology, and tactics. However, psychological studies were clearly under-represented. In particular, the role of self-regulation might deserve more attention to further understand mechanisms relevant for optimal performance and for instance pacing. Another remarkable finding was that the technically/biomechanically favourable crouched skating technique (i.e. small knee and trunk angle) leads to a physiological disadvantage: a smaller knee angle may increase the deoxygenation of the working muscles. This is an important underlying aspect for the pacing tactics in speed skating. Elite speed skaters need to find the optimal balance between obtaining a fast start and preventing negative technical adaptations later on in the race by distributing their available energy over the race in an optimal way. More research is required to gain more insight into how this impacts on the processes of fatigue and coordination during speed skating races. This can lead to a better understanding on how elite speed skaters can maintain the optimal technical characteristics throughout the entire race, and how they can adapt their pacing to optimize all identified aspects that determine performance.
Liposomal Bupivacaine Injection Technique in Total Knee Arthroplasty.
Meneghini, R Michael; Bagsby, Deren; Ireland, Philip H; Ziemba-Davis, Mary; Lovro, Luke R
2017-01-01
Liposomal bupivacaine has gained popularity for pain control after total knee arthroplasty (TKA), yet its true efficacy remains unproven. We compared the efficacy of two different periarticular injection (PAI) techniques for liposomal bupivacaine with a conventional PAI control group. This retrospective cohort study compared consecutive patients undergoing TKA with a manufacturer-recommended, optimized injection technique for liposomal bupivacaine, a traditional injection technique for liposomal bupivacaine, and a conventional PAI of ropivacaine, morphine, and epinephrine. The optimized technique utilized a smaller gauge needle and more injection sites. Self-reported pain scores, rescue opioids, and side effects were compared. There were 41 patients in the liposomal bupivacaine optimized injection group, 60 in the liposomal bupivacaine traditional injection group, and 184 in the conventional PAI control group. PAI liposomal bupivacaine delivered via manufacturer-recommended technique offered no benefit over PAI ropivacaine, morphine, and epinephrine. Mean pain scores and the proportions reporting no or mild pain, time to first opioid, and amount of opioids consumed were not better with PAI liposomal bupivacaine compared with PAI ropivacaine, morphine, and epinephrine. The use of the manufacturer-recommended technique for PAI of liposomal bupivacaine does not offer benefit over a conventional, less expensive PAI during TKA. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Ushiyama, Naoko; Kurobe, Yasushi; Momose, Kimito
2017-11-01
[Purpose] To determine the validity of knee extension muscle strength measurements using belt-stabilized hand-held dynamometry with and without body stabilization compared with the gold standard isokinetic dynamometry in healthy adults. [Subjects and Methods] Twenty-nine healthy adults (mean age, 21.3 years) were included. Study parameters involved right side measurements of maximal isometric knee extension strength obtained using belt-stabilized hand-held dynamometry with and without body stabilization and the gold standard. Measurements were performed in all subjects. [Results] A moderate correlation and fixed bias were found between measurements obtained using belt-stabilized hand-held dynamometry with body stabilization and the gold standard. No significant correlation and proportional bias were found between measurements obtained using belt-stabilized hand-held dynamometry without body stabilization and the gold standard. The strength identified using belt-stabilized hand-held dynamometry with body stabilization may not be commensurate with the maximum strength individuals can generate; however, it reflects such strength. In contrast, the strength identified using belt-stabilized hand-held dynamometry without body stabilization does not reflect the maximum strength. Therefore, a chair should be used to stabilize the body when performing measurements of maximal isometric knee extension strength using belt-stabilized hand-held dynamometry in healthy adults. [Conclusion] Belt-stabilized hand-held dynamometry with body stabilization is more convenient than the gold standard in clinical settings.
Malhotra, Rajesh; Gaba, Sahil; Wahal, Naman; Kumar, Vijay; Srivastava, Deep N; Pandit, Hemant
2018-02-28
Oxford unicompartmental knee replacement (OUKR) has shown excellent long-term clinical outcomes as well as implant survival when used for correct indications with optimal surgical technique. Anteromedial osteoarthritis is highly prevalent in Indian patients, and OUKR is the ideal treatment option in such cases. Uncertainty prevails about the best method to determine femoral component size in OUKR. Preoperative templating has been shown to be inaccurate, while height- and gender-based guidelines based on European population might not apply to the Indian patients. Microplasty instrumentation introduced in 2012 introduced the sizing spoon, which has the dual function of femoral component sizing and determining the level of tibia cut. We aimed to check the accuracy of sizing spoon and also to determine whether the present guidelines are appropriate for use in the Indian patients. A total of 130 consecutive Oxford mobile bearing medial cemented UKR performed using the Microplasty instrumentation were included. The ideal femoral component size for each knee was recorded by looking for overhang and underhang in post-operative lateral knee radiograph. The accuracy of previous guidelines was determined by applying them to our study population. Previously published guidelines (which were based on Western population) proved to be accurate in only 37% of cases. Hence, based on the demographics of our study population, we formulated modified height- and gender-based guidelines, which would better suit the Indian population. Accuracy of modified guidelines was estimated to be 74%. The overall accuracy of sizing spoon (75%), when used as an intraoperative guide, was similar to that of modified guidelines. Existing guidelines for femoral component sizing do not work in Indian patients. Modified guidelines and use of intraoperative spoon should be used to choose the optimal implant size while performing OUKR in Indian patients. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Alaia, Michael J; Khatib, Omar; Shah, Mehul; A Bosco, Joseph; M Jazrawi, Laith; Strauss, Eric J
2015-08-01
To evaluate whether screening radiographs as part of the initial workup of knee pain impacts clinical decision-making in a sports medicine practice. A questionnaire was completed by the attending orthopaedic surgeon following the initial office visit for 499 consecutive patients presenting to the sports medicine centre with a chief complaint of knee pain. The questionnaire documented patient age, duration of symptoms, location of knee pain, associated mechanical symptoms, history of trauma within the past 2 weeks, positive findings on plain radiographs, whether magnetic resonance imaging was ordered, and whether plain radiographs impacted the management decisions for the patient. Patients were excluded if they had prior X-rays, history of malignancy, ongoing pregnancy, constitutional symptoms as well as those patients with prior knee surgery or intra-articular infections. Statistical analyses were then performed to determine which factors were more likely do correspond with diagnostic radiographs. Overall, initial screening radiographs did not change management in 72 % of the patients assessed in the office. The mean age of patients in whom radiographs did change management was 57.9 years compared to 37.1 years in those patients where plain radiograph did not change management (p < 0.0001). Plain radiographs had no impact on clinical management in 97.3 % of patients younger than 40. In patients whom radiographs did change management, radiographs were more likely to influence management if patients were over age forty, had pain for over 6 months, had medial or diffuse pain, or had mechanical symptoms. A basic cost analysis revealed that the cost of a clinically useful radiographic series in a patient under 40 years of age was $7,600, in contrast to $413 for a useful series in patients above the age of 40. Data from the current study support the hypothesis that for the younger patient population, routine radiographic imaging as a screening tool may be of little clinical benefit. Factors supporting obtaining screening radiographs include age greater than 40, knee pain for greater than 6 months, the presence of medial or diffuse knee pain, and the presence of mechanical symptoms. II.
van Tiel, J; Siebelt, M; Reijman, M; Bos, P K; Waarsing, J H; Zuurmond, A-M; Nasserinejad, K; van Osch, G J V M; Verhaar, J A N; Krestin, G P; Weinans, H; Oei, E H G
2016-06-01
Recently, computed tomography arthrography (CTa) was introduced as quantitative imaging biomarker to estimate cartilage sulphated glycosaminoglycan (sGAG) content in human cadaveric knees. Our aim was to assess the correlation between in vivo CTa in human osteoarthritis (OA) knees and ex vivo reference standards for sGAG and collagen content. In this prospective observational study 11 knee OA patients underwent CTa before total knee replacement (TKR). Cartilage X-ray attenuation was determined in six cartilage regions. Femoral and tibial cartilage specimens harvested during TKR were re-scanned using equilibrium partitioning of an ionic contrast agent with micro-CT (EPIC-μCT), which served as reference standard for sGAG. Next, cartilage sGAG and collagen content were determined using dimethylmethylene blue (DMMB) and hydroxyproline assays. The correlation between CTa X-ray attenuation, EPIC-μCT X-ray attenuation, sGAG content and collagen content was assessed. CTa X-ray attenuation correlated well with EPIC-μCT (r = 0.76, 95% credibility interval (95%CI) 0.64 to 0.85). CTa correlated moderately with the DMMB assay (sGAG content) (r = -0.66, 95%CI -0.87 to -0.49) and to lesser extent with the hydroxyproline assay (collagen content) (r = -0.56, 95%CI -0.70 to -0.36). Outcomes of in vivo CTa in human OA knees correlate well with sGAG content. Outcomes of CTa also slightly correlate with cartilage collagen content. Since outcomes of CTa are mainly sGAG dependent and despite the fact that further validation using hyaline cartilage of other joints with different biochemical composition should be conducted, CTa may be suitable as quantitative imaging biomarker to estimate cartilage sGAG content in future clinical OA research. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Schmalz, Thomas; Pröbsting, Eva; Auberger, Roland; Siewert, Gordon
2016-04-01
The microprocessor-controlled leg orthosis C-Brace enables patients with paretic or paralysed lower limb muscles to use dampened knee flexion under weight-bearing and speed-adapted control of the swing phase. The objective of the present study was to investigate the new technical functions of the C-Brace orthosis, based on biomechanical parameters. The study enrolled six patients. The C-Brace orthosis is compared with conventional leg orthoses (four stance control orthoses, two locked knee-ankle-foot orthoses) using biomechanical parameters of level walking, descending ramps and descending stairs. Ground reaction forces, joint moments and kinematic parameters were measured for level walking as well as ascending and descending ramps and stairs. With the C-Brace, a nearly natural stance phase knee flexion was measured during level walking (mean value 11° ± 5.6°). The maximum swing phase knee flexion angle of the C-Brace approached the normal value of 65° more closely than the stance control orthoses (66° ± 8.5° vs 74° ± 6.4°). No significant differences in the joint moments were found between the C-Brace and stance control orthosis conditions. In contrast to the conventional orthoses, all patients were able to ambulate ramps and stairs using a step-over-step technique with C-Brace (flexion angle 64.6° ± 8.2° and 70.5° ± 12.4°). The results show that the functions of the C-Brace for situation-dependent knee flexion under weight bearing have been used by patients with a high level of confidence. The functional benefits of the C-Brace in comparison with the conventional orthotic mechanisms could be demonstrated most clearly for descending ramps and stairs. The C-Brace orthosis is able to combine improved orthotic function with sustained orthotic safety. © The International Society for Prosthetics and Orthotics 2014.
YU, A.; Heilmeier, U.; Kretzschmar, M.; Joseph, G.B.; Liu, F.; Liebl, H.; McCulloch, C.E.; Nevitt, M.C.; Lane, Nancy E.; Link, T.M.
2015-01-01
Objective To determine whether knee cartilage composition differs between African-American and Caucasian-American women at risk for Osteoarthritis using in-vivo 3 Tesla MRI T2 relaxation time measurements. Methods Right knee MRI studies of 200 subjects (100 African-American women, and 100 closely matched Caucasian-American women) were selected from the Osteoarthritis Initiative. Knee cartilage was segmented in the patellar (PAT), medial and lateral femoral (MF/LF), and medial and lateral tibial compartments (MT/LT)). Mean T2 relaxation time values per compartment and per whole joint cartilage were generated and analyzed spatially via laminar and grey-level co-occurrence matrix texture methods. Presence and severity of cartilage lesions per compartment were graded using a modified WORMS grading. Statistical analysis employed paired t- and McNemar testing. Results While African-American women and Caucasian-Americans had similar WORMS cartilage lesion scores (p=0.970), African-Americans showed significantly lower mean T2 values (~1ms difference; ~0.5SD) than Caucasian-Americans in the whole knee cartilage (p<0.001), and in the subcompartments (LF: p=0.001, MF: p<0.001, LT: p=0.019, MT: p=0.001) and particularly in the superficial cartilage layer (whole cartilage: p<0.001, LF: p<0.001, MF: p<0.001, LT: p=0.003, MT: p<0.001). T2 texture parameters were also significantly lower in the whole joint cartilage of African-Americans than in Caucasian-Americans (variance: p=0.001; contrast: p=0.018). In analyses limited to matched pairs with no cartilage lesions in a given compartment, T2 values remained significantly lower in African-Americans. Conclusion Using T2 relaxation time as a biomarker for the cartilage collagen network, our findings suggest racial differences in the biochemical knee cartilage composition between African-American and Caucasian-American women. PMID:25937026
Alteration of swing leg work and power during human accelerated sprinting
Matsubayashi, Takeo; Matsuo, Akifumi; Zushi, Koji
2017-01-01
ABSTRACT This study investigated changes in lower-extremity joint work and power during the swing phase in a maximal accelerated sprinting. Twelve male sprinters performed 60 m maximal sprints while motion data was recorded. Lower-extremity joint work and power during the swing phase of each stride for both legs were calculated. Positive hip and negative knee work (≈4.3 and ≈−2.9 J kg−1) and mean power (≈13.4 and ≈−8.7 W kg−1) during the entire swing phase stabilized or decreased after the 26.2±1.1 (9.69±0.25 m s−1) or 34.3±1.5 m mark (9.97±0.26 m s−1) during the acceleration phase. In contrast, the hip negative work and mean power during the early swing phase (≈7-fold and ≈3.7-fold increase in total), as well as the knee negative work and power during the terminal swing phase (≈1.85-fold and ≈2-fold increase in total), increased until maximal speed. Moreover, only the magnitudes of increases in negative work and mean power at hip and knee joints during the swing phase were positively associated with the increment of running speed from the middle of acceleration phase. These findings indicate that the roles of energy generation and absorption at the hip and knee joints shift around the middle of the acceleration phase as energy generation and absorption at the hip during the late swing phase and at the knee during early swing phase are generally maintained or decreased, and negative work and power at hip during the early swing phase and at knee during the terminal swing phase may be responsible for increasing running speed when approaching maximal speed. PMID:28396485
Novel Contrast Mechanisms at 3 Tesla and 7 Tesla
Regatte, Ravinder R.; Schweitzer, Mark E.
2013-01-01
Osteoarthritis (OA) is the most common musculoskeletal degenerative disease, affecting millions of people. Although OA has been considered primarily a cartilage disorder associated with focal cartilage degeneration, it is accompanied by well-known changes in subchondral and trabecular bone, including sclerosis and osteophyte formation. The exact cause of OA initiation and progression remains under debate, but OA typically first affects weightbearing joints such as the knee. Magnetic resonance imaging (MRI) has been recognized as a potential tool for quantitative assessment of cartilage abnormalities due to its excellent soft tissue contrast. Over the last two decades, several new MR biochemical imaging methods have been developed to characterize the disease process and possibly predict the progression of knee OA. These new MR biochemical methods play an important role not only for diagnosis of disease at an early stage, but also for their potential use in monitoring outcome of various drug therapies (success or failure). Recent advances in multicoil radiofrequency technology and high field systems (3 T and above) significantly improve the sensitivity and specificity of imaging studies for the diagnosis of musculoskeletal disorders. The current state-of-the-art MR imaging methods are briefly reviewed for the quantitative biochemical and functional imaging assessment of musculoskeletal systems. PMID:18850506
De Kleijn, P; Fischer, K; Vogely, H Ch; Hendriks, C; Lindeman, E
2011-11-01
This project aimed to develop guidelines for use during in-hospital rehabilitation after combinations of multiple joint procedures (MJP) of the lower extremities in persons with haemophilia (PWH). MJP are defined as surgical procedures on the ankles, knees and hips, performed in any combination, staged, or during a single session. MJP that we studied included total knee arthroplasty, total hip arthroplasty and ankle arthrodesis. Literature on rheumatoid arthritis demonstrated promising functional results, fewer hospitalization days and days lost from work. However, the complication rate is higher and rehabilitation needs optimal conditions. Since 1995, at the Van Creveldkliniek, 54 PWH have undergone MJP. During the rehabilitation in our hospital performed by experienced physical therapists, regular guidelines seemed useless. Guidelines will guarantee an optimal physical recovery and maximum benefit from this enormous investment. This will lead to an optimal functional capability and optimal quality of life for this elderly group of PWH. There are no existing guidelines for MJP, in haemophilia, revealed through a review of the literature. Therefore, a working group was formed to develop and implement such guidelines and the procedure is explained. The total group of PWH who underwent MJP is described, subdivided into combinations of joints. For these subgroups, the number of days in hospital, complications and profile at discharge, as well as a guideline on the clinical rehabilitation, are given. It contains a general part and a part for each specific subgroup. © 2011 Blackwell Publishing Ltd.
Magnetic plucking of piezoelectric bimorphs for a wearable energy harvester
NASA Astrophysics Data System (ADS)
Pozzi, Michele
2016-04-01
A compact and low-profile energy harvester designed to be worn on the outside of the knee-joint is presented. Frequency up-conversion has been widely adopted in recent times to exploit the high frequency response of piezoelectric transducers within environments where only low frequencies are present. Contactless magnetic plucking is here introduced, in a variable reluctance framework, with the aim of improving the mechanical energy transfer into the transducers, which is sub-optimal with contact plucking. FEA and experiments were used to design an optimal arrangement of ferromagnetic teeth to interact with the magnets fixed to the piezoelectric beams. A prototype was made and extensively tested in a knee-joint simulator controlled with gait data available in the literature. Energy and power produced were measured for walking and running steps. A power management unit was developed using off-the-shelf components, permitting the generation of a stable and regulated supply of 26 mW at 3.3 V during walking. Record levels of rectified (unregulated) electrical power of over 50 and 70 mW per walking and running steps, respectively, were measured.
Hsu, Chao-Jung; George, Steven Z; Chmielewski, Terese L
2016-12-01
Clinicians use the single-leg hop test to assess readiness for return to sports after knee injury. Few studies have reported the results of single-leg hop testing after meniscectomy. Additionally, the contributions of impairments in quadriceps strength and psychosocial factors to single-leg hop performance are unknown. To compare single-leg hop performance (distance and landing mechanics) between limbs and to examine the association of single-leg hop performance with quadriceps strength and psychosocial factors in patients with meniscectomy. Descriptive laboratory study. A total of 22 subjects who underwent meniscectomy for traumatic meniscal tears received either standard rehabilitation alone or with additional quadriceps strengthening. Testing was conducted immediately postrehabilitation and at 1 year postsurgery. A single-leg hop test was performed bilaterally, and hop distance was used to create a hop symmetry index. Landing mechanics (peak knee flexion angle, knee extension moment, and peak vertical ground-reaction force) were analyzed with a motion-capture system and a force plate. An isokinetic dynamometer (60 deg/s) assessed knee extensor peak torque and rate of torque development (RTD 0-200ms and RTD 0-peak torque ). Questionnaires assessed fear of reinjury (Tampa Scale for Kinesiophobia [TSK-11]) and self-efficacy (Knee Activity Self-Efficacy [KASE]). Rehabilitation groups did not significantly differ in single-leg hop performance; therefore, groups were combined for further analyses. The mean hop symmetry index was 88.6% and 98.9% at postrehabilitation and 1 year postsurgery, respectively. Compared with the nonsurgical limb, the surgical limb showed decreased peak knee flexion angle at postrehabilitation and decreased knee extension moment at 1 year postsurgery. The hop symmetry index was positively associated with peak torque, RTD 0-200ms , and the KASE score at postrehabilitation. Moreover, at postrehabilitation, the peak knee flexion angle was positively associated with peak torque and RTD 0-200ms , and the knee extension moment was positively associated with RTD 0-200ms . At 1 year postsurgery, peak knee flexion angle and knee extension moment were both positively associated with peak torque, RTD 0-200ms , and RTD 0-peak torque . Although the hop symmetry index could be considered satisfactory for returning to sports, asymmetries in landing mechanics still exist in the first year postmeniscectomy. Greater quadriceps strength was associated with greater single-leg hop distance and better landing mechanics at both postrehabilitation and 1 year postsurgery. Knee activity self-efficacy was the only psychosocial factor associated with single-leg hop performance and isolated to a positive association with single-leg hop distance at postrehabilitation. Rate of development is not typically measured in the clinic but can be an additional quadriceps measure to monitor for single-leg hop performance. Quadriceps strength and psychosocial factors appear to have separate influence on single-leg hop performance after meniscectomy, which has implications for developing appropriate interventions for optimal single-leg hop performance.
Hsu, Chao-Jung; George, Steven Z.; Chmielewski, Terese L.
2016-01-01
Background: Clinicians use the single-leg hop test to assess readiness for return to sports after knee injury. Few studies have reported the results of single-leg hop testing after meniscectomy. Additionally, the contributions of impairments in quadriceps strength and psychosocial factors to single-leg hop performance are unknown. Purpose: To compare single-leg hop performance (distance and landing mechanics) between limbs and to examine the association of single-leg hop performance with quadriceps strength and psychosocial factors in patients with meniscectomy. Study Design: Descriptive laboratory study. Methods: A total of 22 subjects who underwent meniscectomy for traumatic meniscal tears received either standard rehabilitation alone or with additional quadriceps strengthening. Testing was conducted immediately postrehabilitation and at 1 year postsurgery. A single-leg hop test was performed bilaterally, and hop distance was used to create a hop symmetry index. Landing mechanics (peak knee flexion angle, knee extension moment, and peak vertical ground-reaction force) were analyzed with a motion-capture system and a force plate. An isokinetic dynamometer (60 deg/s) assessed knee extensor peak torque and rate of torque development (RTD0-200ms and RTD0–peak torque). Questionnaires assessed fear of reinjury (Tampa Scale for Kinesiophobia [TSK-11]) and self-efficacy (Knee Activity Self-Efficacy [KASE]). Results: Rehabilitation groups did not significantly differ in single-leg hop performance; therefore, groups were combined for further analyses. The mean hop symmetry index was 88.6% and 98.9% at postrehabilitation and 1 year postsurgery, respectively. Compared with the nonsurgical limb, the surgical limb showed decreased peak knee flexion angle at postrehabilitation and decreased knee extension moment at 1 year postsurgery. The hop symmetry index was positively associated with peak torque, RTD0-200ms, and the KASE score at postrehabilitation. Moreover, at postrehabilitation, the peak knee flexion angle was positively associated with peak torque and RTD0-200ms, and the knee extension moment was positively associated with RTD0-200ms. At 1 year postsurgery, peak knee flexion angle and knee extension moment were both positively associated with peak torque, RTD0-200ms, and RTD0–peak torque. Conclusion: Although the hop symmetry index could be considered satisfactory for returning to sports, asymmetries in landing mechanics still exist in the first year postmeniscectomy. Greater quadriceps strength was associated with greater single-leg hop distance and better landing mechanics at both postrehabilitation and 1 year postsurgery. Knee activity self-efficacy was the only psychosocial factor associated with single-leg hop performance and isolated to a positive association with single-leg hop distance at postrehabilitation. Clinical Relevance: Rate of development is not typically measured in the clinic but can be an additional quadriceps measure to monitor for single-leg hop performance. Quadriceps strength and psychosocial factors appear to have separate influence on single-leg hop performance after meniscectomy, which has implications for developing appropriate interventions for optimal single-leg hop performance. PMID:28210647
Simulation of in vivo dynamics during robot assisted joint movement.
Bobrowitsch, Evgenij; Lorenz, Andrea; Wülker, Nikolaus; Walter, Christian
2014-12-16
Robots are very useful tools in orthopedic research. They can provide force/torque controlled specimen motion with high repeatability and precision. A method to analyze dissipative energy outcome in an entire joint was developed in our group. In a previous study, a sheep knee was flexed while axial load remained constant during the measurement of dissipated energy. We intend to apply this method for the investigation of osteoarthritis. Additionally, the method should be improved by simulation of in vivo knee dynamics. Thus, a new biomechanical testing tool will be developed for analyzing in vitro joint properties after different treatments. Discretization of passive knee flexion was used to construct a complex flexion movement by a robot and simulate altering axial load similar to in vivo sheep knee dynamics described in a previous experimental study. The robot applied an in vivo like axial force profile with high reproducibility during the corresponding knee flexion (total standard deviation of 0.025 body weight (BW)). A total residual error between the in vivo and simulated axial force was 0.16 BW. Posterior-anterior and medio-lateral forces were detected by the robot as a backlash of joint structures. Their curve forms were similar to curve forms of corresponding in vivo measured forces, but in contrast to the axial force, they showed higher total standard deviation of 0.118 and 0.203 BW and higher total residual error of 0.79 and 0.21 BW for posterior-anterior and medio-lateral forces respectively. We developed and evaluated an algorithm for the robotic simulation of complex in vivo joint dynamics using a joint specimen. This should be a new biomechanical testing tool for analyzing joint properties after different treatments.
Taya, Masanobu; Amiya, Eisuke; Hatano, Masaru; Maki, Hisataka; Nitta, Daisuke; Saito, Akihito; Tsuji, Masaki; Hosoya, Yumiko; Minatsuki, Shun; Nakayama, Atsuko; Fujiwara, Takayuki; Konishi, Yuto; Yokota, Kazuhiko; Watanabe, Masafumi; Morita, Hiroyuki; Haga, Nobuhiko; Komuro, Issei
2018-01-15
This study investigated the effectiveness and safety of interval training during in-hospital treatment of patients with advanced heart failure. Twenty-four consecutive patients with advanced symptomatic heart failure who were referred for cardiac transplant evaluation were recruited. After performing aerobic exercise for approximate intensity, high-intensity interval training (HIIT) was performed. The protocol consisted of 3 or 4 sessions of 1-min high-intensity exercise aimed at 80% of peak VO 2 or 80% heart rate reserve, followed by 4-min recovery periods of low intensity. In addition to the necessary laboratory data, hand grip strength and knee extensor strength were evaluated at the start of exercise training and both at the start and the end of HIIT. Knee extensor strength was standardized by body weight. The BNP level at the start of exercise training was 432 (812) pg/mL and it significantly decreased to 254 (400) pg/mL (p < 0.001) at the end of HIIT. Hand grip strength did not change during course. By contrast, knee extensor strength significantly increased during HIIT [4.42 ± 1.43 → 5.28 ± 1.45 N/kg, p < 0.001], whereas the improvement of knee extensor strength was not significant from the start of exercise training to the start of HIIT. In addition, the change in knee extensor strength during HIIT was significantly associated with the hemoglobin A1c level at the start of exercise (R = - 0.55; p = 0.015). HIIT has a positive impact on skeletal muscle strength among in-hospital patients with advanced heart failure.
Hydrodynamic boost: a novel re-entry technique in subintimal angioplasty of below-the-knee vessels.
Ferraresi, Roberto; Hamade, Meneme; Gallicchio, Vito; Troisi, Nicola; Mauri, Giovanni
2016-08-01
To describe the hydrodynamic boost (HB) technique and report our preliminary results with this technique in the subintimal angioplasty of below-the-knee vessels. HB was used in 23 cases (14 males, mean age 73 ± 12 years) of critical limb ischemia, with long chronic total occlusion of tibial arteries extended to the ankle level. The operator performs a manual injection of diluted contrast dye through a 4 F catheter into the subintimal space, close to the patent true distal lumen, in order to achieve a tear in the intimal flap and a connection with the true lumen. In 19/23 (83 %) cases, the HB was effective in creating a connection between the subintimal space and the true distal lumen and it was possible to advance a wire and to conclude the procedure. In 4/23 (17 %) lesions, the HB failed and the procedure was successfully completed by retrograde approach. No major complications occurred. Mean length between catheter tip and re-entry point was 8 ± 5 mm. HB seems to be a feasible, safe and effective re-entry technique in distal below-the-knee vessels. This method represents an easy option for re-entry that extends the possibility of antegrade approach to obtain a successful revascularization. • In subintimal angioplasty of below-the-knee vessel re-entry can represent a challenge. • Inability to re-enter may determine the failure of the revascularization procedure. • HB is a novel re-entry technique feasible in distal below-the-knee vessels. • HB may increase the success rate of antegrade approach. • In case of failure, retrograde approach remains feasible.
Sheehan, Frances T; Borotikar, Bhushan S; Behnam, Abrahm J; Alter, Katharine E
2012-07-01
A potential source of patellofemoral pain, one of the most common problems of the knee, is believed to be altered patellofemoral kinematics due to a force imbalance around the knee. Although no definitive etiology for this imbalance has been found, a weak vastus medialis is considered a primary factor. Therefore, this study's purpose was to determine how the loss of vastus medialis obliquus force alters three-dimensional in vivo knee joint kinematics during a volitional extension task. Eighteen asymptomatic female subjects with no history of knee pain or pathology participated in this IRB approved study. Patellofemoral and tibiofemoral kinematics were derived from velocity data acquired using dynamic cine-phase contrast MRI. The same kinematics were then acquired immediately after administering a motor branch block to the vastus medialis obliquus using 3-5ml of 1% lidocaine. A repeated measures analysis of variance was used to test the null hypothesis that the post- and pre-injection kinematics were no different. The null hypothesis was rejected for patellofemoral lateral shift (P=0.003, max change=1.8mm, standard deviation=1.7mm), tibiofemoral lateral shift (P<0.001, max change=2.1mm, standard deviation=2.9mm), and tibiofemoral external rotation (P<0.001, max change=3.7°, standard deviation=4.4°). The loss of vastus medialis obliquus function produced kinematic changes that mirrored the axial plane kinematics seen in individuals with patellofemoral pain, but could not account for the full extent of these changes. Thus, vastus medialis weakness is likely a major factor in, but not the sole source of, altered patellofemoral kinematics in such individuals. Published by Elsevier Ltd.
Diehm, Nicolas; Sin, Sangmun; Hoppe, Hanno; Baumgartner, Iris; Büchler, Philippe
2011-06-01
To assess if finite element (FE) models can be used to predict deformation of the femoropopliteal segment during knee flexion. Magnetic resonance angiography (MRA) images were acquired on the lower limbs of 8 healthy volunteers (5 men; mean age 28 ± 4 years). Images were taken in 2 natural positions, with the lower limb fully extended and with the knee bent at ~ 40°. Patient-specific FE models were developed and used to simulate the experimental situation. The displacements of the artery during knee bending as predicted by the numerical model were compared to the corresponding positions measured on the MRA images. The numerical predictions showed a good overall agreement between the calculated displacements of the motion measures from MRA images. The average position error comparing the calculated vs. actual displacements of the femoropopliteal intersection measured on the MRA was 8 ± 4 mm. Two of the 8 subjects showed large prediction errors (average 13 ± 5 mm); these 2 volunteers were the tallest subjects involved in the study and had a low body mass index (20.5 kg/m²). The present computational model is able to capture the gross mechanical environment of the femoropopliteal intersection during knee bending and provide a better understanding of the complex biomechanical behavior. However, results suggest that patient-specific mechanical properties and detailed muscle modeling are required to provide accurate patient-specific numerical predictions of arterial displacement. Further adaptation of this model is expected to provide an improved ability to predict the multiaxial deformation of this arterial segment during leg movements and to optimize future stent designs.
Negus, J J; Cawthorne, D P; Chen, J S; Scholes, C J; Parker, D A; March, L M
2015-01-01
Home-based rehabilitation following total knee replacement surgery can be as effective as clinic-based or in-patient rehabilitation. The use of the Nintendo Wii has been postulated as a novel rehabilitation tool that adds an additional focus on balance and proprioception into the recovery protocol. The aim of the proposed clinical trial is to investigate the effectiveness of this novel rehabilitation tool, used at home for three months after total knee replacement surgery and to assess any lasting improvements in functional outcome at one year. This will be a randomised controlled trial of 128 patients undergoing primary total knee replacement. The participants will be recruited preoperatively from three surgeons at a single centre. There will be no change to the usual care provided until 6 weeks after the operation. Then participants will be randomised to either the Wii-Fit group or usual rehabilitative care group. Outcomes will be assessed preoperatively, a 6-week post surgery baseline and then at 18 weeks, 6 months and 1 year. The primary outcome is the change in self-reported WOMAC total score from week 6 to 18 weeks. Secondary outcomes include objective measures of strength, function and satisfaction scores. The results of this clinical trial will be directly relevant for implementation into clinical practice. If beneficial, this affordable technology could be used by many patients to rehabilitate at home. Not only could it optimize the outcomes from their total knee replacement surgery but decrease the need for clinic-based or outpatient therapy for the majority. (ACTRN12611000291987). Copyright © 2014 Elsevier Inc. All rights reserved.
Cryotherapy Treatment After Unicompartmental and Total Knee Arthroplasty: A Review.
Chughtai, Morad; Sodhi, Nipun; Jawad, Michael; Newman, Jared M; Khlopas, Anton; Bhave, Anil; Mont, Michael A
2017-12-01
Cryotherapy is widely utilized to enhance recovery after knee surgeries. However, the outcome parameters often vary between studies. Therefore, the purpose of this review is to compare (1) no cryotherapy vs cryotherapy; (2) cold pack cryotherapy vs continuous flow device cryotherapy; (3) various protocols of application of these cryotherapy methods; and (4) cost-benefit analysis in patients who had unicompartmental knee arthroplasty (UKA) or total knee arthroplasty (TKA). A search for "knee" and "cryotherapy" using PubMed, EBSCO Host, and SCOPUS was performed, yielding 187 initial reports. After selecting for RCTs relevant to our study, 16 studies were included. Of the 8 studies that compared the immediate postoperative outcomes between patients who did and did not receive cryotherapy, 5 studies favored cryotherapy (2 cold packs and 3 continuous cold flow devices). Of the 6 studies comparing the use of cold packs and continuous cold flow devices in patients who underwent UKA or TKA, 3 favor the use of continuous flow devices. There was no difference in pain, postoperative opioid consumption, or drain output between 2 different temperature settings of continuous cold flow device. The optimal device to use may be one that offers continuous circulating cold flow, as there were more studies demonstrating better outcomes. In addition, the pain relieving effects of cryotherapy may help minimize pain medication use, such as with opioids, which are associated with numerous potential side effects as well as dependence and addiction. Meta-analysis on the most recent RCTs should be performed next. Copyright © 2017 Elsevier Inc. All rights reserved.
Measurement of in vivo anterior cruciate ligament strain during dynamic jump landing
Taylor, K.A.; Terry, M.E.; Utturkar, G.M.; Spritzer, C.E.; Queen, R.M.; Irribarra, L.A.; Garrett, W.E.; DeFrate, L.E.
2011-01-01
Despite recent attention in the literature, anterior cruciate ligament (ACL) injury mechanisms are controversial and incidence rates remain high. One explanation is limited data on in vivo ACL strain during high-risk, dynamic movements. The objective of this study was to quantify ACL strain during jump landing. Marker-based motion analysis techniques were integrated with fluoroscopic and magnetic resonance (MR) imaging techniques to measure dynamic ACL strain non-invasively. First, eight subjects’ knees were imaged using MR. From these images, the cortical bone and ACL attachment sites of the tibia and femur were outlined to create 3D models. Subjects underwent motion analysis while jump landing using reflective markers placed directly on the skin around the knee. Next, biplanar fluoroscopic images were taken with the markers in place so that the relative positions of each marker to the underlying bone could be quantified. Numerical optimization allowed jumping kinematics to be superimposed on the knee model, thus reproducing the dynamic in vivo joint motion. ACL length, knee flexion, and ground reaction force were measured. During jump landing, average ACL strain peaked 55 ± 14 ms (mean and 95% confidence interval) prior to ground impact, when knee flexion angles were lowest. The peak ACL strain, measured relative to its length during MR imaging, was 12 ± 7%. The observed trends were consistent with previously described neuromuscular patterns. Unrestricted by field of view or low sampling rate, this novel approach provides a means to measure kinematic patterns that elevate ACL strains and that provide new insights into ACL injury mechanisms. PMID:21092960
Mycobacterium smegmatis infection of a prosthetic total knee arthroplasty.
Saffo, Zaid; Ognjan, Anthony
2016-01-01
The most common organisms causing prosthetic knee joint infections are staphylococci. However, arthroplasty infections with atypical microbial pathogens, such as Mycobacteria can occur. Due to the rarity of mycobacterial prosthetic joint infections, diagnosis, treatment, and management of these atypical infections represent a clinical challenge. A 71-year old female post-operative day 40 after a left total knee arthroplasty was hospitalized secondary to left knee pain and suspected arthroplasty infection. She had failed outpatient oral antimicrobial treatment for superficial stitch abscess; and outpatient IV/Oral antimicrobials for a clinical postoperative septic bursitis. Ultimately, resection arthroplasty with operative tissue acid fast bacterial cultures demonstrated growth of the Mycobacterium smegmatis group. Post-operatively, she completed a combination course of oral doxycycline and levofloxacin and successfully completed a replacement arthroplasty with clinical and microbial resolution of the infection. To our knowledge, literature review demonstrates three case of knee arthroplasty infection caused by the Mycobacterium smegmatis group. Correspondingly, optimal surgical procedures and antimicrobial management including antimicrobial selection, treatment duration are not well defined. Presently, the best treatment options consists of two step surgical management including prosthesis hardware removal followed by extended antimicrobial therapy, followed by consideration for re-implantation arthroplasty. Our case illustrates importance of considering atypical mycobacterial infections in post-operative arthroplasty infections not responding to traditional surgical manipulations and antimicrobials. For an arthroplasty infection involving the atypical Mycobacterium smegmatis group, two step arthroplasty revision, including arthroplasty resection, with a combination of oral doxycycline and levofloxacin can lead to successful infection resolution, allowing for a successful replacement arthroplasty.
Musculoskeletal MRI at 3.0 T and 7.0 T: a comparison of relaxation times and image contrast.
Jordan, Caroline D; Saranathan, Manojkumar; Bangerter, Neal K; Hargreaves, Brian A; Gold, Garry E
2013-05-01
The purpose of this study was to measure and compare the relaxation times of musculoskeletal tissues at 3.0 T and 7.0 T, and to use these measurements to select appropriate parameters for musculoskeletal protocols at 7.0 T. We measured the T₁ and T₂ relaxation times of cartilage, muscle, synovial fluid, bone marrow and subcutaneous fat at both 3.0 T and 7.0 T in the knees of five healthy volunteers. The T₁ relaxation times were measured using a spin-echo inversion recovery sequence with six inversion times. The T₂ relaxation times were measured using a spin-echo sequence with seven echo times. The accuracy of both the T₁ and T₂ measurement techniques was verified in phantoms at both magnetic field strengths. We used the measured relaxation times to help design 7.0 T musculoskeletal protocols that preserve the favorable contrast characteristics of our 3.0 T protocols, while achieving significantly higher resolution at higher SNR efficiency. The T₁ relaxation times in all tissues at 7.0 T were consistently higher than those measured at 3.0 T, while the T₂ relaxation times at 7.0 T were consistently lower than those measured at 3.0 T. The measured relaxation times were used to help develop high resolution 7.0 T protocols that had similar fluid-to-cartilage contrast to that of the standard clinical 3.0 T protocols for the following sequences: proton-density-weighted fast spin-echo (FSE), T₂-weighted FSE, and 3D-FSE-Cube. The T₁ and T₂ changes were within the expected ranges. Parameters for musculoskeletal protocols at 7.0 T can be optimized based on these values, yielding improved resolution in musculoskeletal imaging with similar contrast to that of standard 3.0 T clinical protocols. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Bieler, Theresa; Magnusson, Stig Peter; Christensen, Helle Elisabeth; Kjaer, Michael; Beyer, Nina
2017-07-01
To investigate between-leg differences in hip and thigh muscle strength and leg extensor power in patients with unilateral hip osteoarthritis. Further, to compare between-leg differences in knee extensor strength and leg extensor power between patients and healthy peers. Seventy-two patients (60-87 years) with radiographic and symptomatic hip osteoarthritis not awaiting hip replacement and 35 healthy peers (63-82 years) were included. Hip and thigh muscle strength and leg extensor power were measured in patients and knee extensor strength and leg extensor power in healthy. The symptomatic extremity in patients was significantly (p < 0.05, paired t-test) weaker compared with the non-symptomatic extremity for five hip muscles (8-17%), knee extensors (11%) and leg extensor power (19%). Healthy older adults had asymmetry in knee extensor strength (6%, p < 0.05) comparable to that found in patients, but had no asymmetry in leg extensor power. Patients had generalized weakening of the affected lower extremity and numerically the largest asymmetry was evident for leg extensor power. In contrast, healthy peers had no asymmetry in leg extensor power. These results indicate that exercise interventions focusing on improving leg extensor power of the symptomatic lower extremity and reducing asymmetry may be beneficial for patients with hip osteoarthritis. Implications for Rehabilitation Even in patients with mild symptoms not awaiting hip replacement a generalized muscle weakening of the symptomatic lower extremity seems to be present. Between-leg differences in leg extensor power (force × velocity) appears to be relatively large (19%) in patients with unilateral hip osteoarthritis in contrast to healthy peers who show no asymmetry. Compared to muscle strength the relationship between functional performance and leg extensor power seems to be stronger, and more strongly related to power of the symptomatic lower extremity. Our results indicate that exercise interventions focusing on improving leg extensor power of the symptomatic lower extremity and reducing asymmetry may be beneficial for patients with mild symptoms not awaiting hip replacement.
T2 values of articular cartilage in clinically relevant subregions of the asymptomatic knee.
Surowiec, Rachel K; Lucas, Erin P; Fitzcharles, Eric K; Petre, Benjamin M; Dornan, Grant J; Giphart, J Erik; LaPrade, Robert F; Ho, Charles P
2014-06-01
In order for T2 mapping to become more clinically applicable, reproducible subregions and standardized T2 parameters must be defined. This study sought to: (1) define clinically relevant subregions of knee cartilage using bone landmarks identifiable on both MR images and during arthroscopy and (2) determine healthy T2 values and T2 texture parameters within these subregions. Twenty-five asymptomatic volunteers (age 18-35) were evaluated with a sagittal T2 mapping sequence. Manual segmentation was performed by three raters, and cartilage was divided into twenty-one subregions modified from the International Cartilage Repair Society Articular Cartilage Mapping System. Mean T2 values and texture parameters (entropy, variance, contrast, homogeneity) were recorded for each subregion, and inter-rater and intra-rater reliability was assessed. The central regions of the condyles had significantly higher T2 values than the posterior regions (P < 0.05) and higher variance than the posterior region on the medial side (P < 0.001). The central trochlea had significantly greater T2 values than the anterior and posterior condyles. The central lateral plateau had lower T2 values, lower variance, higher homogeneity, and lower contrast than nearly all subregions in the tibia. The central patellar regions had higher entropy than the superior and inferior regions (each P ≤ 0.001). Repeatability was good to excellent for all subregions. Significant differences in mean T2 values and texture parameters were found between subregions in this carefully selected asymptomatic population, which suggest that there is normal variation of T2 values within the knee joint. The clinically relevant subregions were found to be robust as demonstrated by the overall high repeatability.
Lakin, Benjamin A.; Patel, Harsh; Holland, Conor; Freedman, Jonathan D.; Shelofsky, Joshua S.; Snyder, Brian D.; Stok, Kathryn S.; Grinstaff, Mark W.
2017-01-01
Mouse models of osteoarthritis (OA) are commonly used to study the disease’s pathogenesis and efficacy of potential treatments. However, measuring the biochemical and mechanical properties of articular cartilage in these models currently requires destructive and time-consuming histology and mechanical testing. Therefore, we examined the feasibility of using contrast-enhanced CT (CECT) to rapidly and non-destructively image and assess the glycosaminoglycan (GAG) content. Using three ex vivo C57BL/6 mouse tibial plateaus, we determined the time required for the cationic contrast agent CA4+ to equilibrate in the cartilage. The whole-joint coefficient of friction (μ) of thirteen mouse knees (some digested with Chondroitenase ABC to introduce variation in GAG) was evaluated using a modified Stanton pendulum. For both the medial and lateral tibial plateau cartilage of these knees, linear regression was used to compare the equilibrium CECT attenuations to μ, as well as each side’s indentation equilibrium modulus (E) and Safranin-O determined GAG content. CA4+ equilibrated in the cartilage in 30.9 ± 0.95 min (mean ± SD, tau value of 6.17 ± 0.19 min). The mean medial and lateral CECT attenuation was correlated with μ (R2=0.69, p<0.05), and the individual medial and lateral CECT attenuations correlated with their respective GAG contents (R2≥0.63, p<0.05) and E (R2≥0.63, p<0.05). In conclusion, CECT using CA4+ is a simple, non-destructive technique for three-dimensional imaging of ex vivo mouse cartilage, and significant correlations between CECT attenuation and GAG, E, and μ are observed. PMID:26697956
[Restricted motion after total knee arthroplasty].
Kucera, T; Urban, K; Karpas, K; Sponer, P
2007-10-01
The aim of the study was to ascertain what proportion of patients undergoing total knee arthroplasty (TKA) complain of restricted knee joint motion, and to investigate options for improvement of this situation. Our evaluation included a group of 796 patients treated with TKA at our department in the period from January 1, 1990, to December 31, 2004. In all cases, a condylar implant with preservation of the posterior cruciate ligaments was used. In addition to medical history, the range of motion, knee joint malalignment and radiological findings were assessed before surgery. After THA, the type of implant and complications, if any, were recorded, and improvement in joint motion was followed up. Based on the results of Kim et al., flexion contracture equal to or higher than 15 degrees and/or flexion less than 75 degrees were made the criteria of stiffness after THA. Patients with restricted THA motion who had aseptic or septic implant loosening were not included. Of the 796 evaluated patients, 32 (4.14 %) showed restricted motion after total knee arthroplasty, as assessed by the established criteria. In 16 patients, stiffness defined by these criteria had existed before surgery, and three patients showed an excessive production of adhesions and heterotopic ossifications. In three patients, the implantation procedure resulted in an elevated level of the original joint line and subsequent development of patella infera and increased tension of the posterior cruciate ligament. Four patients declined physical therapy and, in six, the main cause of stiffness could not be found. Seventeen patients did not require surgical therapy for restricted motion; TKA provided significant pain relief and they considered the range of motion achieved to be sufficient. One patient underwent redress 3 months after surgery, but with no success. Repeated releases of adhesions, replacement of a polyethylene liner and revision surgery of the extensor knee structures were performed in 15 patients. In these, the average value of knee flexion increased by 17 degrees only and, in the patients suffering from excessive adhesion production, this value remained almost unchanged. Revision TKA was carried out in four patients, in whom knee joint flexion increased on average by 35 degrees to achieve an average flexion of 83 degrees. Restricted motion after TKA has been reported to range from 1.3 % to 12.0 %, but consistent criteria have not been set up. In our study it was 4.14 %. In agreement with the literature data, one of the reasons was pre-operative restricted motion, which was recorded in 16 of 32 patients. Similarly, also in our patients, biological predisposition to excessive production of fibrocartilage associated with adhesions in all knee joint compartments was the major therapeutic problem. Intra-operative fractures, ligament tears requiring post-operative fixation and unremoved dorsal osteophytes lead to the restriction of knee joint motion. By inadequate resection of articular surface, the original joint line may be at a higher level; this results in an increased tension of the posterior cruciate ligament and patella infera development, both influencing knee flexion. In our study, three patients were affected. Knee joint stiffness can also develop in patients declining physical therapy or in whom this is not correctly performed, often for insufficient analgesia. In contrast to the data reported in the literature, 17 of 32 patients in this study had no need for surgical treatment of restricted knee joint motion. Redress under general anesthesia was not effective. For markedly restricted motion of the knee joint, reimplantation can be recommended or, in less severe cases, an intervention on adjacent soft tissues. Restricted motion of the knee joint after TKA is difficult to treat and, therefore, prevention is recommended. This should include thorough conservative treatment of gonarthrosis, early indication for surgery, prevention of elevation in the joint line and consistent rehabilitation with appropriate analgesia. For severe stiffness of the knee joint, as evaluated by the criteria of Kim et al., revision arthroplasty can be recommended.
Return to sport after total or unicompartmental knee arthroplasty
Dagneaux, Louis; Bourlez, Julien; Degeorge, Benjamin; Canovas, François
2017-01-01
Knee arthroplasty survival rate — either UKA or TKA — is currently 95%, greater than it was ten years ago, but has not been specifically evaluated in very active patients practicing sport at a high intensity. The terms and conditions of return to physical activities are decided by the surgeon, the rehabilitation or Sports Medicine doctor, who needs to make sure that postoperative rehabilitation has been conducted optimally. Specifically, range of movement must be complete, muscular strengthening has to be sufficient and balance must be recovered by proprioception. Only after this stage (i.e. three to six months after surgery) can physical activities be resumed. Return to sport must be gentle and progressive, with moderate activities limited to short sessions. Progressively the patient will be able to return to intermediate activities, provided that he/she possesses the adequate level of technique for the sport. This up-to-date review for young surgeons and residents aims to provide an informative guide for patients regarding sport following knee arthroplasty. Cite this article: EFORT Open Rev 2017;2:496–501. DOI: 10.1302/2058-5241.2.170037 PMID:29387472
Pros and Cons: A Balanced View of Robotics in Knee Arthroplasty.
Lonner, Jess H; Fillingham, Yale A
2018-07-01
In both unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA), compared with conventional techniques robotic technology has been shown to optimize the precision of bone preparation and component alignment, reducing outliers and increasing the percentage of components aligned within 2° or 3° of the target goal. In addition, soft tissue balance can be quantified through a range of motion in UKA and TKA using the various robotic technologies available. Although the presumption has been that the improved alignment associated with robotics will improve function and implant durability, there are limited data to support that notion. Based on recent and emerging data, it may be unreasonable to presume that robotics is necessary for both UKA and TKA. In fact, despite improvements in various proxy measures, the precision of robotics may be more important for UKA than TKA, although if system costs and surgical efficiencies continue to improve, streamlining perioperative processes, reducing instrument inventory, and achieving comparable outcomes in TKA may be a reasonable goal of robotic surgery. Copyright © 2018 Elsevier Inc. All rights reserved.
LED light design method for high contrast and uniform illumination imaging in machine vision.
Wu, Xiaojun; Gao, Guangming
2018-03-01
In machine vision, illumination is very critical to determine the complexity of the inspection algorithms. Proper lights can obtain clear and sharp images with the highest contrast and low noise between the interested object and the background, which is conducive to the target being located, measured, or inspected. Contrary to the empirically based trial-and-error convention to select the off-the-shelf LED light in machine vision, an optimization algorithm for LED light design is proposed in this paper. It is composed of the contrast optimization modeling and the uniform illumination technology for non-normal incidence (UINI). The contrast optimization model is built based on the surface reflection characteristics, e.g., the roughness, the reflective index, and light direction, etc., to maximize the contrast between the features of interest and the background. The UINI can keep the uniformity of the optimized lighting by the contrast optimization model. The simulation and experimental results demonstrate that the optimization algorithm is effective and suitable to produce images with the highest contrast and uniformity, which is very inspirational to the design of LED illumination systems in machine vision.
Haanstra, Tsjitske M.; Tilbury, Claire; Kamper, Steven J.; Tordoir, Rutger L.; Vliet Vlieland, Thea P. M.; Nelissen, Rob G. H. H.; Cuijpers, Pim; de Vet, Henrica C. W.; Dekker, Joost; Knol, Dirk L.; Ostelo, Raymond W.
2015-01-01
Objectives The constructs optimism, pessimism, hope, treatment credibility and treatment expectancy are associated with outcomes of medical treatment. While these constructs are grounded in different theoretical models, they nonetheless show some conceptual overlap. The purpose of this study was to examine whether currently available measurement instruments for these constructs capture the conceptual differences between these constructs within a treatment setting. Methods Patients undergoing Total Hip and Total Knee Arthroplasty (THA and TKA) (Total N = 361; 182 THA; 179 TKA), completed the Life Orientation Test-Revised for optimism and pessimism, the Hope Scale, the Credibility Expectancy Questionnaire for treatment credibility and treatment expectancy. Confirmatory factor analysis was used to examine whether the instruments measure distinct constructs. Four theory-driven models with one, two, four and five latent factors were evaluated using multiple fit indices and Δχ2 tests, followed by some posthoc models. Results The results of the theory driven confirmatory factor analysis showed that a five factor model in which all constructs loaded on separate factors yielded the most optimal and satisfactory fit. Posthoc, a bifactor model in which (besides the 5 separate factors) a general factor is hypothesized accounting for the commonality of the items showed a significantly better fit than the five factor model. All specific factors, except for the hope factor, showed to explain a substantial amount of variance beyond the general factor. Conclusion Based on our primary analyses we conclude that optimism, pessimism, hope, treatment credibility and treatment expectancy are distinguishable in THA and TKA patients. Postdoc, we determined that all constructs, except hope, showed substantial specific variance, while also sharing some general variance. PMID:26214176
Haanstra, Tsjitske M; Tilbury, Claire; Kamper, Steven J; Tordoir, Rutger L; Vliet Vlieland, Thea P M; Nelissen, Rob G H H; Cuijpers, Pim; de Vet, Henrica C W; Dekker, Joost; Knol, Dirk L; Ostelo, Raymond W
2015-01-01
The constructs optimism, pessimism, hope, treatment credibility and treatment expectancy are associated with outcomes of medical treatment. While these constructs are grounded in different theoretical models, they nonetheless show some conceptual overlap. The purpose of this study was to examine whether currently available measurement instruments for these constructs capture the conceptual differences between these constructs within a treatment setting. Patients undergoing Total Hip and Total Knee Arthroplasty (THA and TKA) (Total N = 361; 182 THA; 179 TKA), completed the Life Orientation Test-Revised for optimism and pessimism, the Hope Scale, the Credibility Expectancy Questionnaire for treatment credibility and treatment expectancy. Confirmatory factor analysis was used to examine whether the instruments measure distinct constructs. Four theory-driven models with one, two, four and five latent factors were evaluated using multiple fit indices and Δχ2 tests, followed by some posthoc models. The results of the theory driven confirmatory factor analysis showed that a five factor model in which all constructs loaded on separate factors yielded the most optimal and satisfactory fit. Posthoc, a bifactor model in which (besides the 5 separate factors) a general factor is hypothesized accounting for the commonality of the items showed a significantly better fit than the five factor model. All specific factors, except for the hope factor, showed to explain a substantial amount of variance beyond the general factor. Based on our primary analyses we conclude that optimism, pessimism, hope, treatment credibility and treatment expectancy are distinguishable in THA and TKA patients. Postdoc, we determined that all constructs, except hope, showed substantial specific variance, while also sharing some general variance.
Ong, Carmichael F.; Hicks, Jennifer L.; Delp, Scott L.
2017-01-01
Goal Technologies that augment human performance are the focus of intensive research and development, driven by advances in wearable robotic systems. Success has been limited by the challenge of understanding human–robot interaction. To address this challenge, we developed an optimization framework to synthesize a realistic human standing long jump and used the framework to explore how simulated wearable robotic devices might enhance jump performance. Methods A planar, five-segment, seven-degree-of-freedom model with physiological torque actuators, which have variable torque capacity depending on joint position and velocity, was used to represent human musculoskeletal dynamics. An active augmentation device was modeled as a torque actuator that could apply a single pulse of up to 100 Nm of extension torque. A passive design was modeled as rotational springs about each lower limb joint. Dynamic optimization searched for physiological and device actuation patterns to maximize jump distance. Results Optimization of the nominal case yielded a 2.27 m jump that captured salient kinematic and kinetic features of human jumps. When the active device was added to the ankle, knee, or hip, jump distance increased to between 2.49 and 2.52 m. Active augmentation of all three joints increased the jump distance to 3.10 m. The passive design increased jump distance to 3.32 m by adding torques of 135 Nm, 365 Nm, and 297 Nm to the ankle, knee, and hip, respectively. Conclusion Dynamic optimization can be used to simulate a standing long jump and investigate human-robot interaction. Significance Simulation can aid in the design of performance-enhancing technologies. PMID:26258930
Suzuki, Tomoyuki; Shino, Konsei; Otsubo, Hidenori; Suzuki, Daisuke; Mae, Tatsuo; Fujimiya, Mineko; Yamashita, Toshihiko; Fujie, Hiromichi
2014-10-01
The purpose of this study was to evaluate the effectiveness of 2 anterior cruciate ligament (ACL) reconstruction techniques using a bone-patellar tendon-bone (BPTB) graft with femoral tunnel, either a rectangular tunnel (RET) or a round tunnel (ROT). For experiment 1, nine fresh-frozen human cadaveric knees were tested with a robotic/universal force-moment sensor system to determine the initial optimal tension: the amount of graft tension at 15° of flexion most closely resembling the anterior laxity of a normal knee. The value was estimated by repeatedly measuring anterior laxity when 100 N of anteroposterior drawer load was applied to the knees at 30° of flexion after RET ACL or ROT ACL reconstruction. For experiment 2, six fresh-frozen human cadaveric knees were selected. On the basis of the initial tension determined in experiment 1, RET ACL reconstruction was conducted with the graft tensioned to 10 N, followed by ROT ACL reconstruction on the same knee at 40 N of initial tension, and the biomechanical efficacy of the 2 methods was compared. For experiment 1, the mean laxity match tension at 15° of flexion was 8.6 ± 4.8 N and 34.8 ± 9.2 N for RET- and ROT-reconstructed knees, respectively. For experiment 2, both RET and ROT ACL reconstructions were successful in controlling anterior tibial translation under anterior tibial loads, with the graft initially tensioned to 10 N in the former and to 40 N in the latter. However, the greater tensioning in ROT reconstruction led to proximal, posterior, and lateral displacement of the tibia along with its external and valgus rotation. The RET ACL-reconstructed knee more closely resembled the normal knee in biomechanical behavior. Although ROT reconstruction successfully controlled anterior translation with greater initial tensioning to the graft, the normal positional relation between the tibia and femur was impaired. Rectangular femoral ACL fixation constructs and grafts may prove more efficacious at restoring in vivo ACL kinematics than round femoral tunnels. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Geeslin, Andrew G; Moulton, Samuel G; LaPrade, Robert F
2016-05-01
There is a paucity of outcome data to guide the surgical treatment of acute grade III posterolateral corner (PLC) knee injuries. To systematically review the literature to compare clinical outcomes of the treatment for acute grade III PLC injuries. Systematic review; Level of evidence, 4. A systematic review of the literature including Cochrane, PubMed, Medline, and Embase was performed. The following search terms were used: posterolateral corner knee, posterolateral knee, posterolateral instability, multiligament knee, and knee dislocation. Inclusion criteria were outcome studies of surgically treated acute PLC injuries with a minimum 2-year follow-up, subjective outcomes, objective outcomes including varus stability, and subgroup data on PLC injuries. Two investigators independently reviewed all abstracts. Accepted definitions of varus stability on examination or stress radiographs and the need for revision surgery were used to categorically define success and failure. Eight studies with a total of 134 patients were included. The mean patient age was reported in 7 studies (range, 21-31.5 years). The mean time to surgery was reported in 5 studies (range, 15-24.3 days); surgery was performed within 3 weeks in the other 3 studies. Four studies reported International Knee Documentation Committee scores (range, 78.1-91.3); 5 studies reported Lysholm scores (range, 87.5-90.3). Only 3 studies obtained bilateral varus stress radiographs. Based on an objective evaluation with varus stress examinations or radiographs, there was an overall success rate of 81% and failure rate of 19%. In 2 studies, the fibular collateral ligament and popliteus tendon were repaired and staged cruciate reconstruction performed in most patients; there were 17 failures of 45 patients (38%). In the remainder of the studies, patients were treated with local tissue transfer, hybrid repair for amenable structures or reconstruction for midsubstance tears, or reconstruction of all torn structures; the failure rate was 9%. The repair of acute grade III PLC injuries and staged treatment of combined cruciate injuries were associated with a substantially higher postoperative PLC failure rate. Further research is required to identify the reconstruction technique that provides optimal subjective and objective outcomes. © 2015 The Author(s).
Pistone, Eugenio Maria; Laudani, Luca; Camillieri, Gianluca; Di Cagno, Alessandra; Tomassi, Gabriele; Macaluso, Andrea; Giombini, Arrigo
2016-11-11
To assess the effects of adding a whole-body vibration protocol at optimal frequency (WBV-OF) to a traditional rehabilitation programme (TRP) early after anterior cruciate ligament reconstruction, on maximal strength and balance, in comparison with a traditional rehabilitation programme. A total of 34 anterior cruciate ligament reconstructed patients with hamstring-tendon graft underwent either 4 weeks of WBV-OF training in addition to a traditional rehabilitation programme, or a traditional rehabilitation programme only, starting from the first month after surgery. Patients were assessed for maximal voluntary isometric strength during both knee extension and flexion and for balance on a force platform before, 1 month after treatment and at 3-month follow-up. Strength symmetry of the knee flexor muscles improved in WBV-OF+TRP patients more than in TRP patients 1 month after treatment (mean 66% (standard deviation (SD) 15) vs 58% SD 13), and also at the 3-month follow-up (mean 77% (SD 15) vs 64% (SD 15)), with no differences in balance improvements between the groups. Adding 4-weeks of WBV-OF to a traditional rehabilitation programme 1 month after surgery is effective in improving muscle strength of the knee flexor muscles. This early intervention may be incorporated into current rehabilitation to facilitate early strength recovery of anterior cruciate ligament reconstructed patients.
Rousseau-Saine, Nicolas; Williams, Stephan R; Girard, François; Hébert, Luc J; Robin, Florian; Duchesne, Luc; Lavoie, Frédéric; Ruel, Monique
2018-03-01
Total knee arthroplasty (TKA) reduces knee extensor muscle strength (KES) in the operated limb for several months after the surgery. Immediately after TKA, compared to either inguinal femoral nerve block or placebo, adductor canal block (ACB) better preserves KES. Whether this short-term increase in KES is maintained several weeks after surgery remains unknown. We hypothesized that 48 hours of continuous ACB immediately after TKA would improve KES 6 weeks after TKA, compared to placebo. Patients scheduled for primary unilateral TKA were randomized to receive either a continuous ACB (group ACB) or a sham block (group SHAM) for 48 hours after surgery. Primary outcome was the difference in maximal KES 6 weeks postoperatively, measured with a dynamometer during maximum voluntary isometric contraction. Secondary outcomes included postoperative day 1 (POD1) and day 2 (POD2) KES, pain scores at rest and peak effort, and opioid consumption; variation at 6 weeks of Knee Osteoarthritis Outcome Score, patient satisfaction, and length of hospital stay. Sixty-three subjects were randomized and 58 completed the study. Patients in group ACB had less pain at rest during POD1 and during peak effort on POD1 and POD2, consumed less opioids on POD1 and POD2, and had higher median KES on POD1. There was no significant difference between groups for median KES on POD2, variation of Knee Osteoarthritis Outcome Score, patient satisfaction, and length of stay. There was no difference between groups in median KES 6 weeks after surgery (52 Nm [31-89 Nm] for group ACB vs 47 Nm [30-78 Nm] for group SHAM, P= .147). Continuous ACB provides better analgesia and KES for 24-48 hours after surgery, but does not affect KES 6 weeks after TKA. Further research could evaluate whether standardized and optimized rehabilitation over the long term would allow early KES improvements with ACB to be maintained over a period of weeks or months.
Finite element analysis of constrained total Condylar Knee Prosthesis
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-07-13
Exactech, Inc., is a prosthetic joint manufacturer based in Gainesville, FL. The company set the goal of developing a highly effective prosthetic articulation, based on scientific principles, not trial and error. They developed an evolutionary design for a total knee arthroplasty system that promised improved performance. They performed static load tests in the laboratory with similar previous designs, but dynamic laboratory testing was both difficult to perform and prohibitively expensive for a small business to undertake. Laboratory testing also cannot measure stress levels in the interior of the prosthesis where failures are known to initiate. To fully optimize their designsmore » for knee arthroplasty revisions, they needed range-of-motion stress/strain data at interior as well as exterior locations within the prosthesis. LLNL developed computer software (especially NIKE3D) specifically designed to perform stress/strain computations (finite element analysis) for complex geometries in large displacement/large deformation conditions. Additionally, LLNL had developed a high fidelity knee model for other analytical purposes. The analysis desired by Exactech could readily be performed using NIKE3D and a modified version of the high fidelity knee that contained the geometry of the condylar knee components. The LLNL high fidelity knee model was a finite element computer model which would not be transferred to Exactech during the course of this CRADA effort. The previously performed laboratory studies by Exactech were beneficial to LLNL in verifying the analytical capabilities of NIKE3D for human anatomical modeling. This, in turn, gave LLNL further entree to perform work-for-others in the prosthetics field. There were two purposes to the CRADA (1) To modify the LLNL High Fidelity Knee Model to accept the geometry of the Exactech Total Knee; and (2) To perform parametric studies of the possible design options in appropriate ranges of motion so that an optimum design could be selected for production. Because of unanticipated delays in the CRADA funding, the knee design had to be finalized before the analysis could be accomplished. Thus, the scope of work was modified by the industrial partner. It was decided that it would be most beneficial to perform FEA that would closely replicate the lab tests that had been done as the basis of the design. Exactech was responsible for transmitting the component geometries to Livermore, as well as providing complete data from the quasi-static laboratory loading tests that were performed on various designs. LLNL was responsible for defining the basic finite element mesh and carrying out the analysis. We performed the initial computer simulation and verified model integrity, using the laboratory data. After performing the parametric studies, the results were reviewed with Exactech. Also, the results were presented at the Orthopedic Research Society meeting in a poster session.« less
Distribution of Injectate and Sensory-Motor Blockade After Adductor Canal Block.
Gautier, Philippe E; Hadzic, Admir; Lecoq, Jean-Pierre; Brichant, Jean Francois; Kuroda, Maxine M; Vandepitte, Catherine
2016-01-01
The analgesic efficacy reported for the adductor canal block may be related to the spread of local anesthetic outside the adductor canal. Fifteen patients undergoing knee surgery received ultrasound-guided injections of local anesthetic at the level of the adductor hiatus. Sensory-motor block and spread of contrast solution were assessed. Sensation was rated as "markedly diminished" or "absent" in the saphenous nerve distribution and "slightly diminished" in the sciatic nerve territory without motor deficits. Contrast solution was found in the popliteal fossa. The spread of injectate to the popliteal fossa may contribute to the analgesic efficacy of adductor canal block.
Pneumatic strength assessment device: design and isometric measurement.
Paulus, David C; Reiser, Raoul F; Troxell, Wade O
2004-01-01
In order to load a muscle optimally during resistance exercise, it should be heavily taxed throughout the entire range of motion for that exercise. However, traditional constant resistance squats only tax the lower-extremity muscles to their limits at the "sticking region" or a critical joint configuration of the exercise cycle. Therefore, a linear motion (Smith) exercise machine was modified with pneumatics and appropriate computer control so that it could be capable of adjusting force to control velocity within a repetition of the squat exercise or other exercise performed with the device. Prior to application of this device in a dynamic squat setting, the maximum voluntary isometric force (MVIF) produced over a spectrum of knee angles is needed. This would reveal the sticking region and overall variation in strength capacity. Five incremental knee angles (90, 110, 130, 150, and 170 degrees, where 180 degrees defined full extension) were examined. After obtaining university-approved informed consent, 12 men and 12 women participated in the study. The knee angle was set, and the pneumatic cylinder was pressurized such that the subject could move the barbell slightly but no more than two-centimeters. The peak pressure exerted over a five-second maximum effort interval was recorded at each knee angle in random order and then repeated. The average of both efforts was then utilized for further analysis. The sticking region occurred consistently at a 90 degrees knee angle, however, the maximum force produced varied between 110 degrees and 170 degrees with the greatest frequency at 150 degrees for both men and women. The percent difference between the maximum and minimum MVIF was 46% for men and 57% for women.
Kobayashi, Toshiki; Singer, Madeline L.; Orendurff, Michael S.; Gao, Fan; Daly, Wayne K.; Foreman, K. Bo
2015-01-01
Background The adjustment of plantarflexion resistive moment of an articulated ankle-foot orthosis is considered important in patients post stroke, but the evidence is still limited. Therefore, the aim of this study was to investigate the effect of changing the plantarflexion resistive moment of an articulated ankle-foot orthosis on ankle and knee joint angles and moments in patients post stroke. Methods Gait analysis was performed on 10 subjects post stroke under four different plantarflexion resistive moment conditions using a newly designed articulated ankle-foot orthosis. Data were recorded using a Bertec split-belt instrumented treadmill in a 3-dimensional motion analysis laboratory. Findings The ankle and knee sagittal joint angles and moments were significantly affected by the amount of plantarflexion resistive moment of the ankle-foot orthosis. Increasing the plantarflexion resistive moment of the ankle-foot orthosis induced significant decreases both in the peak ankle plantarflexion angle (P<0.01) and the peak knee extension angle (P<0.05). Also, the increase induced significant increases in the internal dorsiflexion moment of the ankle joint (P<0.01) and significantly decreased the internal flexion moment of the knee joint (P<0.01). Interpretation These results suggest an important link between the kinematic/kinetic parameters of the lower-limb joints and the plantarflexion resistive moment of an articulated ankle-foot orthosis. A future study should be performed to clarify their relationship further so that the practitioners may be able to use these parameters as objective data to determine an optimal plantarflexion resistive moment of an articulated ankle-foot orthosis for improved orthotic care in individual patients. PMID:26149007
Donauer, Katharina; Bomberg, Hagen; Wagenpfeil, Stefan; Volk, Thomas; Meissner, Winfried; Wolf, Alexander
2018-05-14
Total hip and knee replacements are common surgeries, and an optimal pain treatment is essential for early rehabilitation. Since data from randomized controlled trails on the use of regional anesthesia in joint replacements of the lower extremities are conflicting, we analyzed the international PAIN OUT registry for comparison of regional anesthesia vs. general anesthesia regarding pain and morphine consumption on the first postoperative day. International Classification of Diseases-9 (ICD-9) codes were used to identify 2,346 cases for knee and 2,315 for hip arthroplasty between 2010 and 2016 from the PAIN OUT registry. Those were grouped according to anesthesia provided (general, regional, and a combination of both). At the first day after surgery, pain levels and opioid consumption was compared. Adjusted odds ratios (aOR [95% CI]) were calculated with logistic regression and propensity matching was used as a sensitivity analysis. After adjustment for confounders, regional anesthesia was associated with reduced opioid consumption (0.20 [0.13-0.30], p<0.001) and less pain (0.53 [0.36-0.78], p=0.001) than general anesthesia in knee surgery. In hip surgery, regional anesthesia was only associated with reduced opioid consumption (0.17 [0.11-0.26], p<0.001), whereas pain was comparable (1.23 [0.94-1.61], p=0.1). Results from a propensity-matched sensitivity analysis were similar. In total knee arthroplasty, regional anesthesia was associated with less pain and lower opioid consumption. In total hip arthroplasty, regional anesthesia was associated with a lower opioid consumption, however not with reduced pain levels. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Liabaud, Barthelemy; Patrick, David A; Geller, Jeffrey A
2013-12-01
Cruciate retaining total knee replacement has been shown to effectively improve pain and quality of life. Successful outcomes depend on many factors, including the maintenance of a competent posterior cruciate ligament. This study sought to anatomically analyze the percentage of PCL injured during a full transverse, tibial cut, thus altering normal function. One hundred and thirty five consecutive knee MRIs taken from 2006 to 2011 were selected from a single surgeon's database for this study. Only subjects with non-arthritic knees were considered for this study; the lack of degenerative joint disease (DJD) was confirmed via a radiological report. The optimal view of the PCL's tibial attachment was observed using the sagittal view of the knee, with a T1 signal. One hundred and twenty two usable images were viewed electronically, and measurements were made using the standardized transverse cut implant guidelines. The percentage of PCL remaining following the cut was categorized into five different groups: 0% (no PCL undermined), 1-49%, 50-74%, 75-99% and 100% (PCL undermined entirely). Overall only 9.0% (n=11) would have not endured any damage to the PCL with a transverse tibial saw cut, while 79.6% (n=98) would have had 50% or more of the PCL undermined. Of the 98 patients with more than 50% resected, 52.1% (n=51 patients) presented complete destabilization of the PCL. The percentage of PCL destabilized was not significant across age groups (p=0.280), gender (p=0.586), or operative side (p=0.460). Independent of age, gender, and operative side, a majority of PCLs are more than 50% destabilized following the standard transverse tibial cut. II. Copyright © 2013 Elsevier B.V. All rights reserved.
Funato, K; Kanehisa, H; Fukunaga, T
2000-12-01
The purpose of this study was to investigate the profiles of muscle cross-sectional area (CSA) and strength capability in relation to lifting ability in Olympic weight lifters. The subjects were 8 elite senior lifters (ESL, age=25.2+/-1.3 years, height=1.64+/-0.03 m, mass=68.6+/-4.2 kg, mean+/-SEM) and 9 college lifters (CL, 20.8+/-0.3 years, 1.67+/-0.03 m, 70.53.4 kg) whose predetermined weight classes were within the same range. The CSAs of elbow or knee extensor and elbow or knee flexor muscles were measured using a B-mode ultrasound apparatus. Concentric and eccentric maximal voluntary forces were determined with an isokinetic dynamometer at a constant velocity of 1.05 rad/sec. The best score of the total mass lifted in the snatch and the clean and jerk lifts was significantly higher in ESL than in CL even in terms of per unit of fat-free mass. There were no significant differences between the two groups in fat-free mass, muscle CSA and force values with the exception that ESL compared to CL showed significantly greater force in concentric knee flexion. However, the ratios of force to muscle CSA (F/CSAs) in concentric and eccentric elbow extensions, eccentric knee extension and concentric knee flexion were significantly higher in ESL than in CL. The present results indicated that the magnitude of muscular development in limbs was similar in elite senior and college lifters whose predetermined weight classes were within the same range. As compared to college lifters, however, elite senior lifters had a higher F/CSA in specific muscle action modes, which might relate to the optimal execution of the Olympic lifts.
Kobayashi, Toshiki; Singer, Madeline L; Orendurff, Michael S; Gao, Fan; Daly, Wayne K; Foreman, K Bo
2015-10-01
The adjustment of plantarflexion resistive moment of an articulated ankle-foot orthosis is considered important in patients post stroke, but the evidence is still limited. Therefore, the aim of this study was to investigate the effect of changing the plantarflexion resistive moment of an articulated ankle-foot orthosis on ankle and knee joint angles and moments in patients post stroke. Gait analysis was performed on 10 subjects post stroke under four different plantarflexion resistive moment conditions using a newly designed articulated ankle-foot orthosis. Data were recorded using a Bertec split-belt instrumented treadmill in a 3-dimensional motion analysis laboratory. The ankle and knee sagittal joint angles and moments were significantly affected by the amount of plantarflexion resistive moment of the ankle-foot orthosis. Increasing the plantarflexion resistive moment of the ankle-foot orthosis induced significant decreases both in the peak ankle plantarflexion angle (P<0.01) and the peak knee extension angle (P<0.05). Also, the increase induced significant increases in the internal dorsiflexion moment of the ankle joint (P<0.01) and significantly decreased the internal flexion moment of the knee joint (P<0.01). These results suggest an important link between the kinematic/kinetic parameters of the lower-limb joints and the plantarflexion resistive moment of an articulated ankle-foot orthosis. A future study should be performed to clarify their relationship further so that the practitioners may be able to use these parameters as objective data to determine an optimal plantarflexion resistive moment of an articulated ankle-foot orthosis for improved orthotic care in individual patients. Copyright © 2015 Elsevier Ltd. All rights reserved.
Biscarini, Andrea; Botti, Fabio Massimo; Pettorossi, Vito Enrico
2013-09-01
A biomechanical model was developed to simulate the selective effect of the co-contraction force provided by each hamstring muscle on the shear and compressive tibiofemoral joint reaction forces, during open kinetic-chain knee-extension exercises. This model accounts for instantaneous values of knee flexion angle [Formula: see text], angular velocity and acceleration, and for changes in magnitude, orientation, and application point of external resistance. The tibiofemoral shear force (TFSF) largely determines the tensile force on anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL). Biceps femoris is the most effective hamstring muscle in decreasing the ACL-loading TFSF developed by quadriceps contractions for [Formula: see text]. In this range, the semimembranosus generates the dominant tibiofemoral compressive force, which enhances joint stability, opposes anterior/posterior tibial translations, and protects cruciate ligaments. The semitendinosus force provides the greatest decreasing gradient of ACL-loading TFSF for [Formula: see text], and the greatest increasing gradient of tibiofemoral compressive force for [Formula: see text]. However, semitendinosus efficacy is strongly limited by its small physiological section. Hamstring muscles behave as a unique muscle in enhancing the PCL-loading TFSF produced by quadriceps contractions for [Formula: see text]. The levels of hamstrings co-activation that suppress the ACL-loading TFSF considerably shift when the knee angular acceleration is changed while maintaining the same level of knee extensor torque by a concurrent adjustment in the magnitude of external resistance. The knowledge of the specific role and the optimal activation level of each hamstring muscle in ACL protection and tibiofemoral stability are fundamental for planning safe and effective rehabilitative knee-extension exercises.
Rose, Jessica; Cahill-Rowley, Katelyn; Butler, Erin E
2017-11-01
Cerebral palsy (CP) is the most common childhood motor disability and often results in debilitating walking abnormalities, such as flexed-knee and stiff-knee gait. Current medical and surgical treatments are only partially effective in improving gait abnormalities and may cause significant muscle weakness. However, emerging artificial walking technologies, such as step-initiated, multichannel neuromuscular electrical stimulation (NMES), can substantially improve gait patterns and promote muscle strength in children with spastic CP. NMES may also be applied to specific lumbar-sacral sensory roots to reduce spasticity. Development of tablet computer-based multichannel NMES can leverage lightweight, wearable wireless stimulators, advanced control design, and surface electrodes to activate lower-limb muscles. Musculoskeletal models have been used to characterize muscle contributions to unimpaired gait and identify high muscle demands, which can help guide multichannel NMES-assisted gait protocols. In addition, patient-specific NMES-assisted gait protocols based on 3D gait analysis can facilitate the appropriate activation of lower-limb muscles to achieve a more functional gait: stance-phase hip and knee extension and swing-phase sequence of hip and knee flexion followed by rapid knee extension. NMES-assisted gait treatment can be conducted as either clinic-based or home-based programs. Rigorous testing of multichannel NMES-assisted gait training protocols will determine optimal treatment dosage for future clinical trials. Evidence-based outcome evaluation using 3D kinematics or temporal-spatial gait parameters will help determine immediate neuroprosthetic effects and longer term neurotherapeutic effects of step-initiated, multichannel NMES-assisted gait in children with spastic CP. Multichannel NMES is a promising assistive technology to help children with spastic CP achieve a more upright, functional gait. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Kar, Julia; Quesada, Peter M
2012-08-01
Anterior cruciate ligament (ACL) injuries are commonly incurred by recreational and professional women athletes during non-contact jumping maneuvers in sports like basketball and volleyball, where incidences of ACL injury is more frequent to females compared to males. What remains a numerical challenge is in vivo calculation of ACL strain and internal force. This study investigated effects of increasing stop-jump height on neuromuscular and bio-mechanical properties of knee and ACL, when performed by young female recreational athletes. The underlying hypothesis is increasing stop-jump (platform) height increases knee valgus angles and external moments which also increases ACL strain and internal force. Using numerical analysis tools comprised of Inverse Kinematics, Computed Muscle Control and Forward Dynamics, a novel approach is presented for computing ACL strain and internal force based on (1) knee joint kinematics and (2) optimization of muscle activation, with ACL insertion into musculoskeletal model. Results showed increases in knee valgus external moments and angles with increasing stop-jump height. Increase in stop-jump height from 30 to 50 cm lead to increase in average peak valgus external moment from 40.5 ± 3.2 to 43.2 ± 3.7 Nm which was co-incidental with increase in average peak ACL strain, from 9.3 ± 3.1 to 13.7 ± 1.1%, and average peak ACL internal force, from 1056.1 ± 71.4 to 1165.4 ± 123.8 N for the right side with comparable increases in the left. In effect this study demonstrates a technique for estimating dynamic changes to knee and ACL variables by conducting musculoskeletal simulation on motion analysis data, collected from actual stop-jump tasks performed by young recreational women athletes.
PRP for Degenerative Cartilage Disease: A Systematic Review of Clinical Studies
Laver, Lior; Marom, Niv; Dnyanesh, Lad; Mei-Dan, Omer; Espregueira-Mendes, João; Gobbi, Alberto
2016-01-01
Objective: To explore the utilization of platelet-rich plasma (PRP) for degenerative cartilage processes and evaluate whether there is sufficient evidence to better define its potential effects. Design: Systematic literature reviews were conducted in PubMed/MEDLINE and Cochrane electronic databases till May 2015, using the keywords “platelet-rich plasma OR PRP OR autologous conditioned plasma OR ACP AND cartilage OR chondrocyte OR chondrogenesis OR osteoarthritis (OA) OR arthritis.” Results: The final result yielded 29 articles. Twenty-six studies examined PRP administration for knee OA and 3 involved PRP administration for hip OA. The results included 9 prospective randomized controlled trials (RCTs) (8 knee and 1 hip), 4 prospective comparative studies, 14 case series, and 2 retrospective comparative studies. Hyaluronic acid (HA) was used as a control in 11 studies (7 RCTs, 2 prospective comparative studies, and 2 retrospective cohort). Overall, all RCTs reported on improved symptoms compared to baseline scores. Only 2 RCTs—one for knee and one for hip—did not report significant superiority of PRP compared to the control group (HA). Nine out of 11 HA controlled studies showed significant better results in the PRP groups. A trend toward better results for PRP injections in patients with early knee OA and young age was observed; however, lack of uniformity was evident in terms of indications, inclusion criteria, and pathology definitions in the different studies. Conclusion: Current clinical evidence supports the benefit in PRP treatment for knee and hip OA, proven to temporarily relieve pain and improve function of the involved joint with superior results compared with several alternative treatments. Further research to establish the optimal preparation protocol and characteristics of PRP injections for OA is needed. PMID:28317389
Analgesics for orthopedic postoperative pain.
Bourne, Michael H
2004-03-01
Postoperative pain management is critical for optimal care of orthopedic surgery patients. Opioids, administered intramuscularly, as epidurals, or IV as patient-controlled analgesia, are effective for severe pain. Adjunctive therapy and preemptive analgesia such as nerve blocks, and methods of delivery such as infusion pumps, may be used after total knee arthroplasty and anterior cruciate ligament (ACL) reconstruction. Oral opioids are effective for moderate to severe pain, and tramadol, with efficacy comparable to morphine but with fewer severe side effects, is selected for moderate to moderately severe pain. Opioid-sparing NSAIDs, such as ketorolac, and COX-2-specific NSAIDS have use in pain management of hip, knee, and ACL procedures. An individualized regimen of appropriate analgesics, combined with nonpharmacologic treatments such as physical therapy or cryotherapy and patient education, can aid orthopedic surgery patients' recovery.
High-energy x-ray Talbot-Lau radiography of a human knee
NASA Astrophysics Data System (ADS)
Horn, F.; Gelse, K.; Jabari, S.; Hauke, C.; Kaeppler, S.; Ludwig, V.; Meyer, P.; Michel, T.; Mohr, J.; Pelzer, G.; Rieger, J.; Riess, C.; Seifert, M.; Anton, G.
2017-08-01
We report on a radiographic measurement of an ex vivo human knee using a grating-based phase-contrast imaging setup and a medical x-ray tube at a tube voltage of 70 kV. The measurement has been carried out using a Talbot-Lau setup that is suitable to achieve a high visibility in the energy regime of medical imaging. In a medical reading by an experienced trauma surgeon signatures of chondrocalcinosis in the medial meniscus have been identified more evidently using the dark-field image in comparison to the conventional attenuation image. The analysis has been carried out at various dose levels down to 0.14 mGy measured as air kerma, which is a dose comparable to clinically used radiographic devices. The diagnosis has been confirmed by a histological analysis of the meniscus tissue. In the introduced high-frequency filtered phase-contrast image the anterior and posterior horn of the medial meniscus and the posterior cruciate ligament have also been visible. Furthermore, atherosclerotic plaque is visible in both imaging modalities, attenuation and dark-field, despite the presence of overlaying bone. This measurement, for the first time, proves the feasibility of Talbot-Lau x-ray imaging at high-energy spectra above 40 kVp and reasonable dose levels with regard to spacious and dense objects.
Patel, B N; Thomas, J V; Lockhart, M E; Berland, L L; Morgan, D E
2013-02-01
To evaluate lesion contrast in pancreatic adenocarcinoma patients using spectral multidetector computed tomography (MDCT) analysis. The present institutional review board-approved, Health Insurance Portability and Accountability Act of 1996 (HIPAA)-compliant retrospective study evaluated 64 consecutive adults with pancreatic adenocarcinoma examined using a standardized, multiphasic protocol on a single-source, dual-energy MDCT system. Pancreatic phase images (35 s) were acquired in dual-energy mode; unenhanced and portal venous phases used standard MDCT. Lesion contrast was evaluated on an independent workstation using dual-energy analysis software, comparing tumour to non-tumoural pancreas attenuation (HU) differences and tumour diameter at three energy levels: 70 keV; individual subject-optimized viewing energy level (based on the maximum contrast-to-noise ratio, CNR); and 45 keV. The image noise was measured for the same three energies. Differences in lesion contrast, diameter, and noise between the different energy levels were analysed using analysis of variance (ANOVA). Quantitative differences in contrast gain between 70 keV and CNR-optimized viewing energies, and between CNR-optimized and 45 keV were compared using the paired t-test. Thirty-four women and 30 men (mean age 68 years) had a mean tumour diameter of 3.6 cm. The median optimized energy level was 50 keV (range 40-77). The mean ± SD lesion contrast values (non-tumoural pancreas - tumour attenuation) were: 57 ± 29, 115 ± 70, and 146 ± 74 HU (p = 0.0005); the lengths of the tumours were: 3.6, 3.3, and 3.1 cm, respectively (p = 0.026); and the contrast to noise ratios were: 24 ± 7, 39 ± 12, and 59 ± 17 (p = 0.0005) for 70 keV, the optimized energy level, and 45 keV, respectively. For individuals, the mean ± SD contrast gain from 70 keV to the optimized energy level was 59 ± 45 HU; and the mean ± SD contrast gain from the optimized energy level to 45 keV was 31 ± 25 HU (p = 0.007). Significantly increased pancreatic lesion contrast was noted at lower viewing energies using spectral MDCT. Individual patient CNR-optimized energy level images have the potential to improve lesion conspicuity. Copyright © 2012 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Kulkarni, J; Adams, J; Thomas, E; Silman, A
1998-08-01
To investigate the association between amputation, osteoarthritis and osteopenia in male war veterans with major lower limb amputations. Specific questions were to determine whether lower limb amputees following trauma are at subsequent risk of developing osteoarthritis (OA) and osteoporosis of the hip on both the amputated and nonamputated sides. Retrospective cohort study in British Male Second World War veterans with major unilateral lower limb amputations. Seventy-five male Second World War veterans with major lower limb amputations known to be alive were invited to participate from a subregional rehabilitation centre. After exclusions, 44 agreed to attend for examination and radiological screening. The presence of hip OA was determined from a single anterior posterior pelvic X-ray using two approaches: minimum joint space and the Kellgren and Lawrence (K&L) scoring system. Bone mineral density (BMD) was measured by a dual energy X-ray absorptiometry (DXA) scan and prosthetic rehabilitation outcome measures were recorded. Twenty-seven (61%) hips on the amputated side and 10 (23%) on the nonamputated side were positive for OA (based on Kellgren and Lawrence grade of >2). Using a minimum joint space threshold of below 2.5 mm, 24 (55%) hips on the amputation side and 8 (18%) on the nonamputated side were also positive for OA. There was a threefold increased risk of OA for those with above-knee compared to a below-knee amputation. By contrast, from published general population surveys only 4 (11%) cases of hip OA would have been expected on both the amputated and nonamputated hips. There was a significant decrease in femoral neck BMD in the amputated side (p <0.0001) and significantly lower BMD in above-knee amputees than in below-knee amputees (p = 0.0027) as compared to normal age- and sex-matched population. Male war veterans with unilateral major lower limb amputations develop significantly more osteoarthritis of the hip than expected on both ipsi- and contralateral sides. Amputation was also associated with loss of bone density. Above-knee amputees develop significantly more hip osteoarthritis and osteopenia of greater severity in the amputated side than below-knee amputees.
Mau-Moeller, Anett; Behrens, Martin; Finze, Susanne; Bruhn, Sven; Bader, Rainer; Mittelmeier, Wolfram
2014-05-09
The parallel-group randomized active-controlled clinical study was conducted to compare the effectiveness of two in-hospital range of motion (ROM) exercise programs following total knee arthroplasty (TKA). Continuous passive motion (CPM) is frequently used to increase ROM and improve postoperative recovery despite little conclusive scientific evidence. In contrast, a new active sling-based ROM therapy requires the activation of the knee joint muscles and dynamic joint stabilization. It was hypothesized that higher demands on muscle strength and muscle coordination during sling exercise training (ST) might be advantageous for early recovery following TKA. A total of 125 patients undergoing primary TKA were assessed for eligibility. Thirty-eight patients were randomly assigned to receive ST or CPM (control intervention) during hospital stay. Patients were assessed before TKA for baseline measurement (pretest), 1 day before discharge (posttest) and 3 months after TKA (follow-up). The passive knee flexion range of motion (pFL) was the primary outcome measure. Secondary outcome measures included active knee flexion range of motion, active and passive knee extension ROM, static postural control, physical activity, pain, length of hospital stay as well as clinical, functional and quality-of-life outcomes (SF-36, HSS and WOMAC scores). Data were analyzed according to the intention-to-treat principle. Differences between the groups were tested for significance by the unpaired Student's t test or an analysis of covariance (ANCOVA) adjusted for baseline, weight, sex, age, pain and physical activity. A between-group difference could be determined at posttest. The pFL was significantly higher by 6.0° (95% CI 0.9 to 11.2°; P = 0.022) in the ST group. No difference between groups in pFL was documented at follow-up. Furthermore, no significant differences could be observed for any secondary outcome measure at posttest and follow-up. ST seems to have a clinically relevant beneficial short-term effect on pFL compared to CPM. The results support the implementation of ST in rehabilitation programs following TKA. Therapy, level 2b.
Maintenance of the paraspinal muscles may protect against radiographic knee osteoarthritis.
Azuma, Koichiro; Sera, Yasushi; Shinjo, Takuma; Takayama, Michiyo; Shiomi, Eisuke; Momoshima, Suketaka; Iwao, Yasushi; Ishida, Hiroyuki; Matsumoto, Hideo
2017-01-01
Knee osteoarthritis (OA) is an increasing health problem worldwide. So far, only obesity and quadriceps weakness are identified as modifiable risk factors for knee OA. Core muscle strengthening is becoming increasingly popular among older adults because of its ability to enhance the activities of daily living during old age. This study investigated the associations of the size and quality of the abdominal trunk muscles with radiographic knee osteoarthritis (RKOA). From 2012 to 2016, data were collected from 146 males and 135 females (age 63.9±13.4 years, BMI 23.2±3.8 kg/m 2 ) at annual musculoskeletal examinations, including knee radiographs and body composition analyses, by dual-energy X-ray absorptiometry. Cross-sectional areas of abdominal trunk muscles were measured using a single-slice computed tomography scan image obtained at the level of the umbilicus. The prevalence of RKOA was 21.2% in males and 28.1% in females. Compared to subjects without RKOA, subjects with RKOA were ~6 years older and had smaller paraspinal muscle (38.4±8.7 vs 33.1±10.1 cm 2 , p <0.01 in males; 24.1±7.1 vs 20.7±7.5 cm 2 , p <0.05 in females). In contrast, there was no decrease in appendicular or total lean mass, and only in females, BMI and total fat mass (FM) were higher in subjects with RKOA (21.5±3.5 vs 24.5±4.4 kg/m 2 , 16.7±7.0 vs 20.5±7.7 kg, respectively, both p <0.01). After adjusting for age and sex, smaller cross-sectional area/lower attenuation value of the paraspinal muscles was associated with RKOA (both p <0.05), while greater appendicular or total lean mass as well as greater FM was associated with RKOA. The size and quality of the paraspinal muscles were not associated with knee pain or habitual exercise. Small, poor-quality paraspinal muscles may be linked to a higher risk of RKOA, but appendicular or total lean mass was not a good predictor of RKOA.
Taylor, Jeffrey B; Nguyen, Anh-Dung; Paterno, Mark V; Huang, Bin; Ford, Kevin R
2017-02-07
Anterior cruciate ligament (ACL) injuries in female athletes lead to a variety of short- and long-term physical, financial, and psychosocial ramifications. While dedicated injury prevention training programs have shown promise, ACL injury rates remain high as implementation has not become widespread. Conventional prevention programs use a combination of resistance, plyometric, balance and agility training to improve high-risk biomechanics and reduce the risk of injury. While many of these programs focus on reducing knee abduction load and posture during dynamic activity, targeting hip extensor strength and utilization may be more efficacious, as it is theorized to be an underlying mechanism of injury in adolescent female athletes. Biofeedback training may complement traditional preventive training, but has not been widely studied in connection with ACL injuries. We hypothesize that biofeedback may be needed to maximize the effectiveness of neuromuscular prophylactic interventions, and that hip-focused biofeedback will improve lower extremity biomechanics to a larger extent than knee-focused biofeedback during dynamic sport-specific tasks and long-term movement strategies. This is an assessor-blind, randomized control trial of 150 adolescent competitive female (9-19 years) soccer players. Each participant receives 3x/week neuromuscular preventive training and 1x/week biofeedback, the mode depending on their randomization to one of 3 biofeedback groups (hip-focused, knee-focused, sham). The primary aim is to assess the impact of biofeedback training on knee abduction moments (the primary biomechanical predictor of future ACL injury) during double-leg landings, single-leg landings, and unplanned cutting. Testing will occur immediately before the training intervention, immediately after the training intervention, and 6 months after the training intervention to assess the long-term retention of modified biomechanics. Secondary aims will assess performance changes, including hip and core strength, power, and agility, and the extent to which maturation effects biofeedback efficacy. The results of the Real-time Optimized Biofeedback Utilizing Sport Techniques (ROBUST) trial will help complement current preventive training and may lead to clinician-friendly methods of biofeedback to incorporate into widespread training practices. Date of publication in ClinicalTrials.gov: 20/04/2016. ClinicalTrials.gov Identifier: NCT02754700 .
Muscle function in elite master weightlifters.
Pearson, Stephen J; Young, Archie; Macaluso, Andrea; Devito, Giuseppe; Nimmo, Myra A; Cobbold, Matthew; Harridge, Stephen D R
2002-07-01
To determine whether explosive power and isometric strength of the lower-limb muscles in elite master Olympic weightlifters declines at a similar rate to nontrained healthy controls with increasing age. 54 elite level masters weightlifters (aged 40-87), who were competitors at the World Masters Weightlifting Championships (1999), were compared with a similar number of aged-matched, healthy untrained individuals. Isometric knee extensor strength and lower-limb explosive power were tested. Extent of antagonist co-contraction during isometric knee extension was determined by EMG and power loading characteristics by using a variable inertial system. Muscle volume was estimated using anthropometry. On average, the weightlifters were able to generate 32% more peak power (P < 0.05) in the lower limbs and 32% more isometric knee extensor force (P < 0.05) than the control subjects. No significant differences in lower-leg volume were observed between the two groups. Peak power declined at a similar rate with increasing age in the weightlifters and controls (1.2 and 1.3% of a 45-yr-old's value per year), as did strength, but at a lower rate (0.6 and 0.5% per year). The inertial load at which the weightlifters achieved their maximal peak power output was greater (P < 0.05) than the controls. The torque generated at this optimal inertia was also greater in the weightlifters (P < 0.05), whereas the time taken for the weightlifters to reach their maximal peak power was on average 13% shorter (P < 0.05). No differences in antagonist co-contraction during isometric knee extension were observed between the two groups. Muscle power and isometric strength decline at a similar rate with increasing age in elite master weightlifters and healthy controls. In spite of inertial load optimization, muscle power declined in both groups at approximately twice the rate of isometric strength. Although similar rates of decline were observed, the absolute differences between the weightlifters and controls were such that an 85-yr-old weightlifter was as powerful as a 65-yr-old control subject. This would therefore represent an apparent age advantage of approximately 20 yr for the weightlifters.
Mechanism design and optimization of a bionic kangaroo jumping robot
NASA Astrophysics Data System (ADS)
Zhang, Y. H.; Zheng, L.; Ge, W. J.; Zou, Z. H.
2018-03-01
Hopping robots have broad application prospects in the fields of military reconnaissance, field search or life rescue. However, current hopping robots still face the problems of weak jumping ability and load bearing. Inspired by the jumping of kangaroo, we design a Kangaroo hopping robot “Zbot”, which has two degrees of freedom and three joints. The geared five-bar mechanism is used to decouple the knee and ankle joints of the robot. In order to get a bionic performance, the coupling mechanism parameters are optimized. The simulation and experiments show that the robot has an excellent jumping ability and load capacity.
Onetti, C M; Gutiérrez, E; Hliba, E; Aguirre, C R
1982-01-01
Synoviorthesis was performed in 217 joints from 111 patients suffering from different stages of rheumatoid arthritis (RA). 32P-colloidal chromic phosphate was employed, with an average dose from 6 mCi for large joints (knees) to 0.3 mCi for small peripheral joints such as average dose from 6 mCi for large joints (knees) to 0.3 mCi for small peripheral joints such as the MCP or PIP joints. Satisfactory clinical results were observed in 84% of the cases and no significant side effects resulted after a follow-up period from 1 to 10 years. Striking effects after treatment were observed through histopathological studies (light and electron microscopy) and the use of contrast arthrography. We concluded that radioactive synovectomy with 32P-chromate is a very useful method for the local treatment of RA.
Smink, Agnes J; Bierma-Zeinstra, Sita M A; Schers, Henk J; Swierstra, Bart A; Kortland, Joke H; Bijlsma, Johannes W J; Teerenstra, Steven; Voorn, Theo B; Dekker, Joost; Vliet Vlieland, Thea P M; van den Ende, Cornelia H M
2014-08-01
To improve the management of hip or knee osteoarthritis (OA), a stepped care strategy (SCS) has been developed that presents the optimal sequence for care in three steps. This study evaluates the extent to which clinical practice is consistent with the strategy after implementation and identifies determinants of SCS-consistent care. A 2-year observational prospective cohort study. General practices in the region of Nijmegen in the Netherlands. Three hundred and thirteen patients with hip or knee OA and their general practitioner (GP). Multifaceted interventions were developed to implement the strategy. Consistency between clinical practice and the strategy was examined regarding three aspects of care: (i) timing of radiological assessment, (ii) sequence of non-surgical treatment options and (iii) making follow-up appointments. Out of the 212 patients who reported to have had an X-ray, 92 (44%) received it in line with the SCS. The sequence of treatment was inconsistent with the SCS in 58% of the patients, which was mainly caused by the underuse of lifestyle advice and dietary therapy. In 57% of the consultations, the patient reported to have been advised to make a follow-up appointment. No determinants that influenced all three aspects of care were identified. Consistency with the SCS was found in about half of the patients for each of the three aspects of care. Health care can be further optimized by encouraging GP s to use X-rays more appropriately and to make more use of lifestyle advice, dietary therapy and follow-up appointments. © The Author 2014. Published by Oxford University Press in association with the International Society for Quality in Health Care; all rights reserved.
Effects of Cementing on Ligament Balance During Total Knee Arthroplasty.
Chow, Jimmy; Wang, Kevin; Elson, Leah; Anderson, Christopher; Roche, Martin
2017-05-01
Complications related to joint imbalance may contribute to some of the most predominant modes of failure in total knee arthroplasty (TKA). These complications include instability, aseptic loosening, asymmetric component wear, and idiopathic pain. Fixation may represent a step that introduces unchecked variability into the procedure and may contribute to the incidence of joint imbalance-related complications. The ability to quantify in vivo loading in the medial and lateral compartments would allow for the ability to confirm balance after fixation and prior to wound closure. This retrospective study sought to capture any variability and imbalance associated with cementing technique. A total of 93 patients underwent sensor-assisted TKA. All patients were confirmed to have quantifiably balanced joints prior to cementation. After cementing and final component placement, the sensor was reinserted into the joint to capture any cementation-induced changes in loading. Imbalance was observed in 44% of patients after cementation. There was no difference in the proportion of imbalance due to surgeon experience (P=.456), cement type (P=.429), or knee system (P=.792). A majority of knees exhibited loading increase in the medial compartment. It was concluded that cementation technique contributes to a significant amount of balance-related variability at the fixation stage of the procedure. The use of the sensor in this study allowed for the correction of all instances of imbalance prior to closure. More objective methods of balance verification may be important for ensuring optimal surgical outcomes. [Orthopedics. 2017; 40(3):e455-e459.]. Copyright 2017, SLACK Incorporated.
Xue, Zhe; Song, Guan-Yang; Liu, Xin; Zhang, Hui; Wu, Guan; Qian, Yi; Feng, Hua
2018-03-20
The purpose of the study was to quantify the patellar J sign using traditional computed tomography (CT) scans. Fifty-three patients (fifty-three knees) who suffered from recurrent patellar instability were included and analyzed. The patellar J sign was evaluated pre-operatively during active knee flexion and extension. It was defined as positive when there was obvious lateral patellar translation, and negative when there was not. The CT scans were performed in all patients with full knee extension; and the parameters including bisect offset index (BOI), patellar-trochlear-groove (PTG) distance, and patellar lateral tilt angle (PLTA) were measured on the axial slices. All the three parameters were compared between the J sign-positive group (study group) and the J sign-negative group (control group). In addition, the optimal thresholds of the three CT scan parameters for predicting the positive patellar J sign were determined with receiver operating characteristic (ROC) curves, and the diagnostic values were assessed by the area under the curve (AUC). Among the fifty-three patients (fifty-three knees), thirty-seven (70%) showed obvious lateral patellar translation, which were defined as positive J sign (study group), and the remaining sixteen (30%) who showed no lateral translation were defined as negative J sign (control group). The mean values of the three CT parameters in the study group were all significantly larger compared to the control group, including BOI (121 ± 28% vs 88 ± 12%, P = 0.038), PTG distance (5.2 ± 6.6 mm vs - 4.4 ± 5.2 mm, P < 0.05), and PLTA (34.9 ± 10.5° vs 25.7 ± 3.4°, P = 0.001). Furthermore, the evaluation of ROC analysis showed that the AUC of BOI was the largest (AUC = 0.906) among the three parameters, and the optimal threshold of BOI to predict the positive patellar J sign was 97.5% (Sensitivity = 83.3%, Specificity = 87.5%). In this study, the prevalence of positive patellar J sign was 70%. The BOI measured from the axial CT scans of the knee joint can be used as an appropriate predictor to differentiate the positive J sign from the negative J sign, highlighting that the excessive lateral patellar translation on axial CT scan indicates positive patellar J sign. IV.
Knee implant imaging at 3 Tesla using high-bandwidth radiofrequency pulses.
Bachschmidt, Theresa J; Sutter, Reto; Jakob, Peter M; Pfirrmann, Christian W A; Nittka, Mathias
2015-06-01
To investigate the impact of high-bandwidth radiofrequency (RF) pulses used in turbo spin echo (TSE) sequences or combined with slice encoding for metal artifact correction (SEMAC) on artifact reduction at 3 Tesla in the knee in the presence of metal. Local transmit/receive coils feature increased maximum B1 amplitude, reduced SAR exposition and thus enable the application of high-bandwidth RF pulses. Susceptibility-induced through-plane distortion scales inversely with the RF bandwidth and the view angle, hence blurring, increases for higher RF bandwidths, when SEMAC is used. These effects were assessed for a phantom containing a total knee arthroplasty. TSE and SEMAC sequences with conventional and high RF bandwidths and different contrasts were tested on eight patients with different types of implants. To realize scan times of 7 to 9 min, SEMAC was always applied with eight slice-encoding steps and distortion was rated by two radiologists. A local transmit/receive knee coil enables the use of an RF bandwidth of 4 kHz compared with 850 Hz in conventional sequences. Phantom scans confirm the relation of RF bandwidth and through-plane distortion, which can be reduced up to 79%, and demonstrate the increased blurring for high-bandwidth RF pulses. In average, artifacts in this RF mode are rated hardly visible for patients with joint arthroplasties, when eight SEMAC slice-encoding steps are applied, and for patients with titanium fixtures, when TSE is used. The application of high-bandwidth RF pulses by local transmit coils substantially reduces through-plane distortion artifacts at 3 Tesla. © 2014 Wiley Periodicals, Inc.
Arabatzi, Fotini; Kellis, Eleftherios
2012-08-01
The purpose of this study was to compare the effects of an Olympic weightlifting (OL) and traditional weight (TW) training program on muscle coactivation around the knee joint during vertical jump tests. Twenty-six men were assigned randomly to 3 groups: the OL (n = 9), the TW (n = 9), and Control (C) groups (n = 8). The experimental groups trained 3 d · wk(-1) for 8 weeks. Electromyographic (EMG) activity from the rectus femoris and biceps femoris, sagittal kinematics, vertical stiffness, maximum height, and power were collected during the squat jump, countermovement jump (CMJ), and drop jump (DJ), before and after training. Knee muscle coactivation index (CI) was calculated for different phases of each jump by dividing the antagonist EMG activity by the agonist. Analysis of variance showed that the CI recorded during the preactivation and eccentric phases of all the jumps increased in both training groups. The OL group showed a higher stiffness and jump height adaptation than the TW group did (p < 0.05). Further, the OL showed a decrease or maintenance of the CI recorded during the propulsion phase of the CMJ and DJs, which is in contrast to the increase in the CI observed after TW training (p < 0.05). The results indicated that the altered muscle activation patterns about the knee, coupled with changes of leg stiffness, differ between the 2 programs. The OL program improves jump performance via a constant CI, whereas the TW training caused an increased CI, probably to enhance joint stability.
Phase synchronisation of the three leg joints in quiet human stance.
Günther, Michael; Putsche, Peter; Leistritz, Lutz; Grimmer, Sten
2011-03-01
Quiet human stance is a dynamic multi-segment phenomenon. In literature, coupled ankle and hip actions are in the focus and examinations are usually restricted to frequency contributions below 4 Hz. Very few studies point to the knee playing an active role, and just one study gives evidence of higher frequency contributions. In order to investigate the dynamic coupling of all three leg joints in more depth, we revisited an experimental data set on quiet human stance. Since phase synchronisation is a strong indicator of non-linear coupling behind, we used the phase synchronisation index (PSI) to quantify the degree of leg joint coupling as a function of frequency. One main result is that we did not find any synchronisation between ankle and hip across the whole frequency range examined up to 8 Hz. In contrast, there is significant synchronisation between ankle and knee at a couple of frequencies between 1.25 Hz and 8 Hz when looking at the kinematics. Their joint torques rather synchronise below 2 Hz. There is also synchronisation between knee and hip kinematics above 6 Hz, however, only significant at one frequency bin in our data set. From this, we would infer that the multiple mechanical degrees of freedom contributing to quiet human stance should be chosen according to, thus map, physiology. Thereby, the knee is indispensable and bi-articular muscles play a central role in organising quiet human stance. Examining the non-stationarity of phase synchronisations will probably advance the understanding of self-organisation of quiet human stance. Copyright © 2010 Elsevier B.V. All rights reserved.
Fermor, H L; McLure, S W D; Taylor, S D; Russell, S L; Williams, S; Fisher, J; Ingham, E
2015-01-01
This study aimed to determine the optimal starting material for the development of an acellular osteochondral graft. Osteochondral tissues from three different species were characterised; pig (6 months), cow (18 months) and two ages of sheep (8-12 months and >4 year old). Tissues from the acetabulum and femoral head of the hip, and the groove, medial and lateral condyles and tibial plateau of the knee were assessed. Histological analysis of each tissue allowed for qualification of cartilage histoarchitecture, glycosaminoglycan (GAG) distribution, assessment of cellularity and cartilage thickness. Collagen and GAG content were quantified and cartilage water content was defined. Following biomechanical testing, the percentage deformation, permeability and equilibrium elastic modulus was determined. Results showed that porcine cartilage had the highest concentration of sulphated proteoglycans and that the condyles and groove of the knee showed higher GAG content than other joint areas. Cartilage from younger tissues (porcine and young ovine) had higher cell content and was thicker, reflecting the effects of age on cartilage structure. Cartilage from older sheep had a much higher elastic modulus and was less permeable than other species.
Naturalness preservation image contrast enhancement via histogram modification
NASA Astrophysics Data System (ADS)
Tian, Qi-Chong; Cohen, Laurent D.
2018-04-01
Contrast enhancement is a technique for enhancing image contrast to obtain better visual quality. Since many existing contrast enhancement algorithms usually produce over-enhanced results, the naturalness preservation is needed to be considered in the framework of image contrast enhancement. This paper proposes a naturalness preservation contrast enhancement method, which adopts the histogram matching to improve the contrast and uses the image quality assessment to automatically select the optimal target histogram. The contrast improvement and the naturalness preservation are both considered in the target histogram, so this method can avoid the over-enhancement problem. In the proposed method, the optimal target histogram is a weighted sum of the original histogram, the uniform histogram, and the Gaussian-shaped histogram. Then the structural metric and the statistical naturalness metric are used to determine the weights of corresponding histograms. At last, the contrast-enhanced image is obtained via matching the optimal target histogram. The experiments demonstrate the proposed method outperforms the compared histogram-based contrast enhancement algorithms.
Geeslin, Andrew G; Chahla, Jorge; Moatshe, Gilbert; Muckenhirn, Kyle J; Kruckeberg, Bradley M; Brady, Alex W; Coggins, Ashley; Dornan, Grant J; Getgood, Alan M; Godin, Jonathan A; LaPrade, Robert F
2018-05-01
The individual kinematic roles of the anterolateral ligament (ALL) and the distal iliotibial band Kaplan fibers in the setting of anterior cruciate ligament (ACL) deficiency require further clarification. This will improve understanding of their potential contribution to residual anterolateral rotational laxity after ACL reconstruction and may influence selection of an anterolateral extra-articular reconstruction technique, which is currently a matter of debate. Hypothesis/Purpose: To compare the role of the ALL and the Kaplan fibers in stabilizing the knee against tibial internal rotation, anterior tibial translation, and the pivot shift in ACL-deficient knees. We hypothesized that the Kaplan fibers would provide greater tibial internal rotation restraint than the ALL in ACL-deficient knees and that both structures would provide restraint against internal rotation during a simulated pivot-shift test. Controlled laboratory study. Ten paired fresh-frozen cadaveric knees (n = 20) were used to investigate the effect of sectioning the ALL and the Kaplan fibers in ACL-deficient knees with a 6 degrees of freedom robotic testing system. After ACL sectioning, sectioning was randomly performed for the ALL and the Kaplan fibers. An established robotic testing protocol was utilized to assess knee kinematics when the specimens were subjected to a 5-N·m internal rotation torque (0°-90° at 15° increments), a simulated pivot shift with 10-N·m valgus and 5-N·m internal rotation torque (15° and 30°), and an 88-N anterior tibial load (30° and 90°). Sectioning of the ACL led to significantly increased tibial internal rotation (from 0° to 90°) and anterior tibial translation (30° and 90°) as compared with the intact state. Significantly increased internal rotation occurred with further sectioning of the ALL (15°-90°) and Kaplan fibers (15°, 60°-90°). At higher flexion angles (60°-90°), sectioning the Kaplan fibers led to significantly greater internal rotation when compared with ALL sectioning. On simulated pivot-shift testing, ALL sectioning led to significantly increased internal rotation and anterior translation at 15° and 30°; sectioning of the Kaplan fibers led to significantly increased tibial internal rotation at 15° and 30° and anterior translation at 15°. No significant difference was found when anterior tibial translation was compared between the ACL/ALL- and ACL/Kaplan fiber-deficient states on simulated pivot-shift testing or isolated anterior tibial load. The ALL and Kaplan fibers restrain internal rotation in the ACL-deficient knee. Sectioning the Kaplan fibers led to greater tibial internal rotation at higher flexion angles (60°-90°) as compared with ALL sectioning. Additionally, the ALL and Kaplan fibers contribute to restraint of the pivot shift and anterior tibial translation in the ACL-deficient knee. This study reports that the ALL and distal iliotibial band Kaplan fibers restrain anterior tibial translation, internal rotation, and pivot shift in the ACL-deficient knee. Furthermore, sectioning the Kaplan fibers led to significantly greater tibial internal rotation when compared with ALL sectioning at high flexion angles. These results demonstrate increased rotational knee laxity with combined ACL and anterolateral extra-articular knee injuries and may allow surgeons to optimize the care of patients with this injury pattern.
Evolution of the hominin knee and ankle.
Frelat, Mélanie A; Shaw, Colin N; Sukhdeo, Simone; Hublin, Jean-Jacques; Benazzi, Stefano; Ryan, Timothy M
2017-07-01
The dispersal of the genus Homo out of Africa approximately 1.8 million years ago (Ma) has been understood within the context of changes in diet, behavior, and bipedal locomotor efficiency. While various morphological characteristics of the knee and ankle joints are considered part of a suite of traits indicative of, and functionally related to, habitual bipedal walking, the timing and phylogenetic details of these morphological changes remain unclear. To evaluate the timing of knee and ankle joint evolution, we apply geometric morphometric methods to three-dimensional digital models of the proximal and distal tibiae of fossil hominins, Holocene Homo sapiens, and extant great apes. Two sets of landmarks and curve semilandmarks were defined on each specimen. Because some fossils were incomplete, digital reconstructions were carried out independently to estimate missing landmarks and semilandmarks. Group shape variation was evaluated through shape-and form-space principal component analysis and fossil specimens were projected to assess variation in the morphological space computed from the extant comparative sample. We show that a derived proximal tibia (knee) similar to that seen in living H. sapiens evolved with early Homo at ∼2 Ma. In contrast, derived characteristics in the distal tibia appear later, probably with the arrival of Homo erectus. These results suggest a dissociation of the morphologies of the proximal and distal tibia, perhaps indicative of divergent functional demands and, consequently, selective pressures at these joints. It appears that longer distance dispersals that delivered the Dmanisi hominins to Georgia by 1.8 Ma and H. erectus to east-southeast Asia by 1.6 Ma were facilitated by the evolution of a morphologically derived knee complex comparable to that of recent humans and an ankle that was morphologically primitive. This research sets the foundation for additional paleontological, developmental, and functional research to better understand the mechanisms underlying the evolution of bipedalism. Copyright © 2017 Elsevier Ltd. All rights reserved.
Gersing, A S; Solka, M; Joseph, G B; Schwaiger, B J; Heilmeier, U; Feuerriegel, G; Nevitt, M C; McCulloch, C E; Link, T M
2016-07-01
To investigate compositional cartilage changes measured with 3T MRI-based T2 values over 48 months in overweight and obese individuals with different degrees of weight loss (WL) and to study whether WL slows knee cartilage degeneration and symptom worsening. We studied participants from the Osteoarthritis Initiative with risk factors or radiographic evidence of mild to moderate knee osteoarthritis with a baseline BMI ≥25 kg/m(2). We selected subjects who over 48 months lost a, moderate (BMI change, 5-10%WL, n = 180) or large amount of weight (≥10%WL, n = 78) and frequency-matched these to individuals with stable weight (<3%, n = 258). Right knee cartilage T2 maps of all compartments and grey-level co-occurrence matrix (GLCM) texture analyses were evaluated and associations with WL and clinical symptoms (WOMAC subscales for pain, stiffness and disability) were assessed using multivariable regression models. The amount of weight change was significantly associated with change in cartilage T2 of the medial tibia (β 0.9 ms, 95% CI 0.4 to 1.1, P = 0.001). Increase of T2 in the medial tibia was significantly associated with increase in WOMAC pain (β 0.5 ms, 95% CI 0.2 to 0.6, P = 0.02) and disability (β 0.03 ms, 95% CI 0.003 to 0.05, P = 0.03). GLCM contrast and variance over all compartments showed significantly less progression in the >10%WL group compared to the stable weight group (both comparisons, P = 0.04). WL over 48 months is associated with slowed knee cartilage degeneration and improved knee symptoms. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Lantsberg, L; Goldman, M
1991-04-01
The level of amputation continues to present a challenge for surgeons. In view of this, 24 patients who required an amputation of their ischaemic leg were studied prospectively using Laser Doppler flowmetry (LDF), TcpO2 measurements and Doppler ultrasound to assess the best level for amputation. In all patients gangrene of the leg and rest pain were the indication for an amputation. Skin oxygen tension (TcpO2) and skin blood flow (LDF) measurements were obtained the day before surgery on the proposed anterior and posterior skin flaps for below knee amputation and the maximum Doppler systolic pressure was measured. The level of amputation was chosen at surgery by clinical judgement without reference to the measurements mentioned above. A below knee amputation was performed in 17 patients and an above knee in seven. All amputations healed by primary intention. Doppler pressures showed poor discrimination with a median value of 10 mmHg (0-25) in AK patients and 35 mmHg (0-85) in the BK group (p greater than 0.05). In contrast TcpO2 showed a trend. In the BK group the median value was 20 mmHg (4-50) on the anterior and 22 mmHg (2-60) on the posterior flap compared to above knee amputees with median values of 6 mmHg (2-11) and 8 mmHg (3-38), respectively (p greater than 0.05). Laser Doppler seemed more useful. In BK patients the median LDF values were 36 mV (20-85) on the anterior and 34 mV (20-80) on the posterior flap with median LDF values of 10 mV (10-18) on the anterior and 11 mV (8-38) on the posterior flap in the above knee group (p less than 0.01). Laser Doppler flowmetry is a simple objective test, which is a better discriminator of skin flap perfusion than either TcpO2 or Doppler ankle pressures.
Galvin, Catherine R; Perriman, Diana M; Newman, Phillip M; Lynch, Joseph T; Smith, Paul N; Scarvell, Jennie M
2018-05-22
Understanding healthy deep flexion kinematics will inform the design of conservative clinical rehabilitation strategies for knee osteoarthritis and contribute to improved knee prosthesis design. This study is a systematic review and meta-analysis of the kinematic outcomes measured at the healthy tibiofemoral joint during loaded deep knee flexion. A computerised literature search and bibliography review without date restriction identified twelve studies with 164 participants aged 25-61 years in-vivo, and 69-93 years in-vitro. Flexion higher than 120° was achieved by squatting, lunging or kneeling. Measurement technologies in-vivo included radiographs, open MRI and 2D-3D MRI or CT image registration on fluoroscopy. Microscribe was used in-vitro. Outcomes were either six degrees-of-freedom based on femur movement or contact patterns on the tibial plateau. The meta-analysis demonstrated that in-vivo, between 120° and 135° of flexion, the tibia internally rotated (mean difference (MD) = 4.6°, 95% CI 3.55° to 5.64°). Both the medial-femoral-condyle and lateral-femoral-condyle translated posteriorly, (MD = 10.4 mm, 95% CI 6.9 to 13.9 mm) and (MD = 5.55 mm, 95% CI 4.64 to 6.46 mm) respectively. There was some evidence of femoral medial translation (3.8 mm) and adduction (1.9° to 3.3°), together with medial compression (1.7 mm) and lateral distraction (1.9) mm. Across the in-vivo studies, consistent kinematic patterns emerged; despite the various measurement technologies and reference methods. In contrast, in-vivo and in-vitro results were contradictory. This systematic review protocol was registered with the International Prospective Register of Systematic Reviews (PROSPERO) on 25 February 2017 (registration number: 42017057614). Copyright © 2018 Elsevier B.V. All rights reserved.
Intraoperative Considerations for Treatment/Prevention of Prosthetic Joint Infection.
Suleiman, Linda I; Mesko, Daniel R; Nam, Denis
2018-06-23
Innovative measures have recently been proposed to prevent periprosthetic joint infection following total hip and knee arthroplasty. We sought to review these recent innovations to determine the reported reduction in periprosthetic joint infection. The most recent literature demonstrates promising results in regard to hydrofiber dressings as an independent risk factor for primary prosthetic joint infection reduction, which in turn is also linked with cost savings. As our understanding of safe yet effective concentrations of antiseptic solutions develops, dilute betadine in particular has demonstrated encouraging efficacy which warrants continued investigation through controlled trials. In summary, we found that the application of a hydrofiber dressing may prove beneficial in decreasing the risk of prosthetic joint infection following primary total hip and knee arthroplasty. The gold standard for an infection prevention protocol continues to be explored and optimized.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zbijewski, W., E-mail: wzbijewski@jhu.edu; Gang, G. J.; Xu, J.
2014-02-15
Purpose: Cone-beam CT (CBCT) with a flat-panel detector (FPD) is finding application in areas such as breast and musculoskeletal imaging, where dual-energy (DE) capabilities offer potential benefit. The authors investigate the accuracy of material classification in DE CBCT using filtered backprojection (FBP) and penalized likelihood (PL) reconstruction and optimize contrast-enhanced DE CBCT of the joints as a function of dose, material concentration, and detail size. Methods: Phantoms consisting of a 15 cm diameter water cylinder with solid calcium inserts (50–200 mg/ml, 3–28.4 mm diameter) and solid iodine inserts (2–10 mg/ml, 3–28.4 mm diameter), as well as a cadaveric knee withmore » intra-articular injection of iodine were imaged on a CBCT bench with a Varian 4343 FPD. The low energy (LE) beam was 70 kVp (+0.2 mm Cu), and the high energy (HE) beam was 120 kVp (+0.2 mm Cu, +0.5 mm Ag). Total dose (LE+HE) was varied from 3.1 to 15.6 mGy with equal dose allocation. Image-based DE classification involved a nearest distance classifier in the space of LE versus HE attenuation values. Recognizing the differences in noise between LE and HE beams, the LE and HE data were differentially filtered (in FBP) or regularized (in PL). Both a quadratic (PLQ) and a total-variation penalty (PLTV) were investigated for PL. The performance of DE CBCT material discrimination was quantified in terms of voxelwise specificity, sensitivity, and accuracy. Results: Noise in the HE image was primarily responsible for classification errors within the contrast inserts, whereas noise in the LE image mainly influenced classification in the surrounding water. For inserts of diameter 28.4 mm, DE CBCT reconstructions were optimized to maximize the total combined accuracy across the range of calcium and iodine concentrations, yielding values of ∼88% for FBP and PLQ, and ∼95% for PLTV at 3.1 mGy total dose, increasing to ∼95% for FBP and PLQ, and ∼98% for PLTV at 15.6 mGy total dose. For a fixed iodine concentration of 5 mg/ml and reconstructions maximizing overall accuracy across the range of insert diameters, the minimum diameter classified with accuracy >80% was ∼15 mm for FBP and PLQ and ∼10 mm for PLTV, improving to ∼7 mm for FBP and PLQ and ∼3 mm for PLTV at 15.6 mGy. The results indicate similar performance for FBP and PLQ and showed improved classification accuracy with edge-preserving PLTV. A slight preference for increased smoothing of the HE data was found. DE CBCT discrimination of iodine and bone in the knee was demonstrated with FBP and PLTV at 6.2 mGy total dose. Conclusions: For iodine concentrations >5 mg/ml and detail size ∼20 mm, material classification accuracy of >90% was achieved in DE CBCT with both FBP and PL at total doses <10 mGy. Optimal performance was attained by selection of reconstruction parameters based on the differences in noise between HE and LE data, typically favoring stronger smoothing of the HE data, and by using penalties matched to the imaging task (e.g., edge-preserving PLTV in areas of uniform enhancement)« less
González Sotelo, V; Maculé, F; Minguell, J; Bergé, R; Franco, C; Sala-Blanch, X
2017-12-01
Total knee arthroplasty (TKA) is an operation with moderate to severe postoperative pain. The Fast-Track models employ local infiltration techniques with anaesthetics at high volumes (100-150ml). We proposed a genicular nerve block with low volume of local anaesthetic. The aim of our study is to evaluate the periarticular distribution of these blocks in a fresh cadaver model and to describe the technique in a preliminary group of patients submitted to TKA. In the anatomical phase, 4 genicular nerves (superior medial, superior lateral, inferior medial and inferior lateral) were blocked with 4ml of local anaesthetic with iodinated contrast and methylene blue in each (16ml in total). It was performed on a fresh cadaver and the distribution of the injected medium was evaluated by means of a CT-scan and coronal anatomical sections on both knees. The clinical phase included 12 patients scheduled for TKA. Ultrasound-guided block of the 4 genicular nerves was performed preoperatively and their clinical efficacy evaluated by assessing pain after the reversal of the spinal block and at 12h after the block. Pain was measured using the numerical scale and the need for rescue analgesia was evaluated. A wide periarticular distribution of contrast was observed by CT-scan, which was later evaluated in the coronal sections. The distribution followed the joint capsule without entering the joint, both in the femur and in the tibia. The pain after the reversal of the subarachnoid block was 2±1, requiring rescue analgesia in 42% of the patients. At 12h, the pain according to the numerical scale was 4±1, 33% required rescue analgesia. The administration of 4ml of local anaesthetic at the level of the 4 genicular nerves of the knee produces a wide periarticular distribution. Our preliminary data in a series of 12 patients undergoing TKA seems to be clinically effective. Nevertheless, extensive case series and comparative studies with local infiltration techniques with anaesthetics are needed to support these encouraging results. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.
Altahawi, Faysal F; Blount, Kevin J; Morley, Nicholas P; Raithel, Esther; Omar, Imran M
2017-01-01
To compare a faster, new, high-resolution accelerated 3D-fast-spin-echo (3D-FSE) acquisition sequence (CS-SPACE) to traditional 2D and high-resolution 3D sequences for knee 3-T magnetic resonance imaging (MRI). Twenty patients received knee MRIs that included routine 2D (T1, PD ± FS, T2-FS; 0.5 × 0.5 × 3 mm 3 ; ∼10 min), traditional 3D FSE (SPACE-PD-FS; 0.5 × 0.5 × 0.5 mm 3 ; ∼7.5 min), and accelerated 3D-FSE prototype (CS-SPACE-PD-FS; 0.5 × 0.5 × 0.5 mm 3 ; ∼5 min) acquisitions on a 3-T MRI system (Siemens MAGNETOM Skyra). Three musculoskeletal radiologists (MSKRs) prospectively and independently reviewed the studies with graded surveys comparing image and diagnostic quality. Tissue-specific signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were also compared. MSKR-perceived diagnostic quality of cartilage was significantly higher for CS-SPACE than for SPACE and 2D sequences (p < 0.001). Assessment of diagnostic quality of menisci and synovial fluid was higher for CS-SPACE than for SPACE (p < 0.001). CS-SPACE was not significantly different from SPACE but had lower assessments than 2D sequences for evaluation of bones, ligaments, muscles, and fat (p ≤ 0.004). 3D sequences had higher spatial resolution, but lower overall assessed contrast (p < 0.001). Overall image quality from CS-SPACE was assessed as higher than SPACE (p = 0.007), but lower than 2D sequences (p < 0.001). Compared to SPACE, CS-SPACE had higher fluid SNR and CNR against all other tissues (all p < 0.001). The CS-SPACE prototype allows for faster isotropic acquisitions of knee MRIs over currently used protocols. High fluid-to-cartilage CNR and higher spatial resolution over routine 2D sequences may present a valuable role for CS-SPACE in the evaluation of cartilage and menisci.
Barile, Antonio; Sabatini, Mylene; Iannessi, Francesca; Di Cesare, Ernesto; Splendiani, Alessandra; Calvisi, Vittorio; Masciocchi, Carlo
2004-04-01
Pigmented villonodular synovitis (PVNS) is a rare proliferative disorder of the synovial membrane, exhibiting benign behaviour from a biological point of view. This kind of synovial hyperplasia leads to the formation of villi and nodules characterized by deposit of intracellular haemosiderin. It primarily involves young adults, the peak age being between the second and fourth decade of life. It may appear either in a diffuse or a localized (nodular) form. The joint most affected is the knee and diffuse PVNS is the most common form. Diagnostic imaging techniques, particularly MRI, allow lesion identification, suggesting a diagnosis. However, such diagnosis can be confirmed only on histology as the final diagnosis of PVNS, and therefore the possibility of differential diagnosis with other haemorrhagic and chronic hyperplastic synovites, is based on the detection of intracellular haemosiderin components. The aim of this study is to evaluate the usefulness of MRI, which might be completed with the intravenous injection of contrast medium, in the characterization of such pathological picture. From January 1999 to December 2002, we evaluated 52 patients presenting knee swelling, pain and functional impairment. Only 19 patients had a history of trauma. All patients underwent MRI using a dedicated 0.2 T unit or a whole-body' 1.5 T unit. In 30 cases the baseline examination was completed with intravenous injection of contrast medium, followed by dynamic 3D-SPGR sequences at 45, 90, 135 and 225 seconds from the initial injection. These dynamic sequences were then processed by means of early and late subtractions, evaluating the regions of interest (ROI) positioned in the areas with higher post-contrast enhancement. Thirty-eight patients had been previously submitted to Ultrasonography (US), whereas twenty-five patients to Computed Tomography (TC). Later, all patients underwent surgery. Only two patients required an arthrotomy. We then retrospectively evaluated the imaging findings obtained, comparing them with the histological data. Patients affected by autoimmune and systemic inflammatory disorders were excluded from this study. The suspected diagnosis of PVNS was confirmed in 44/52 patients examined. CT examination allowed to detect the presence of a synovial proliferation with densitometric values ranging from 55 to 75 Hounsfield Units (HU) in all cases. In 11 cases, US examination revealed the presence of nodular hyperechoic structures surrounded by anechoic areas, with no differentiation between diffuse and nodular forms. Baseline MRI images showed no differential features among the various histological forms detected. In fact, the nodular structures demonstrated intermediate-to-low intensity signal in all sequences performed. Contrast enhanced MRI showed the presence of areas of inhomogeneous signal due to the increased intensity signal of hypervascular areas. The analysis of vascular dynamics demonstrated a characteristic exponential intensity/time curve both in diffuse and localized forms. The definition of pigmented villonodular synovitis was first employed by Jaffé in 1941 to describe the benign proliferative inflammatory nature of such pathology, characterized by a thickened and hyperplastic synovia organized into villi and nodules, leading to deposition of intracellular haemosiderin pigments. Presently, Authors prefer to include in hemorrhagic synovites all chronic and haemorragic synovial disorders, regardless of the aetiopathogenesis (rheumatoid arthritis, arthropathy secondary to haemorrhagic diathesis, chronic articular traumatism, haemangioma, synovial sarcoma). PVNS involves young adults, with no gender preference; it affects the knee joint in 66-80% of cases, with no typical symptomatology. The absolute absence of any characteristic feature makes a correct differential diagnosis difficult. So far, the only possibility to diagnose PVNS is based on the histological examination: presence of intracellular and subsynovial haemosiderin pigments, predominance of nodular structures as compared to villi, presence of macrophage multinucleate cells, production of collagen, mitotic cellular elements. Therefore, the possibility of characterizing PVNS using MRI is based on detection of a higher number of nodules as compared to villi, as the presence of haemosiderin is always characterized by low signal intensity on T2-weighted images, both intra- and extracellularly. New information on MRI semeiotics has come from the use of post-contrast enhanced dynamic sequences which are able to provide semi-quantitative data on CM velocity distribution within the hyperplastic areas. However, in our experience, dynamic-enhanced MRI did not provide any differential feature between PVNS and the other chronic hemorrhagic forms. Any inflammatory pathology leads to an increased capillary permeability with progressive deposit of CM in the area of interest. In all cases examined, the maximum deposit of contrast medium was observed in the extracellular phase, with a delayed wash-out. PVNS of the knee presents a difficult differential diagnosis. In many cases, only MRI is able to identify the presence of haemosiderin precipitates within the nodules characterizing the lesion. The use of standard and dynamic contrast media seems unable to provide additional diagnostic information. Thus, the diagnosis still pertains to histology.
Brincks, John; Christensen, Lars Ejsing; Rehnquist, Mette Voigt; Petersen, Jesper; Sørensen, Henrik; Dalgas, Ulrik
2018-01-01
To improve walking in persons with multiple sclerosis (MS), it is essential to understand the underlying mechanisms of walking. This study examined strategies in net joint power generated or absorbed by hip flexors, hip extensors, hip abductors, knee extensors, and plantar flexors in mildly disabled persons with MS and healthy controls at different walking speeds. Thirteen persons with MS and thirteen healthy controls participated and peak net joint power was calculated using 3D motion analysis. In general, no differences were found between speed-matched healthy controls and persons with MS, but the fastest walking speed was significantly higher in healthy controls (2.42 m/s vs. 1.70 m/s). The net joint power increased in hip flexors, hip extensors, hip abductors, knee extensors and plantar flexors in both groups, when walking speed increased. Significant correlations between changes in walking speed and changes in net joint power of plantar flexors, hip extensors and hip flexors existed in healthy controls and persons with MS, and in net knee extensor absorption power of persons with MS only. In contrast to previous studies, these findings suggest that mildly disabled persons with MS used similar kinetic strategies as healthy controls to increase walking speed.
Rattner, J B; Matyas, J R; Barclay, L; Holowaychuk, S; Sciore, P; Lo, I K Y; Shrive, N G; Frank, C B; Achari, Y; Hart, D A
2011-08-01
Menisci help maintain the structural integrity of the knee. However, the poor healing potential of the meniscus following a knee injury can not only end a career in sports but lead to osteoarthritis later in life. Complete understanding of meniscal structure is essential for evaluating its risk for injury and subsequent successful repair. This study used novel approaches to elucidate meniscal architecture. The radial and circumferential collagen fibrils in the meniscus were investigated using novel tissue-preparative techniques for light and electron microscopic studies. The results demonstrate a unique architecture based on differences in the packaging of the fundamental collagen fibrils. For radial arrays, the collagen fibrils are arranged in parallel into ∼10 μm bundles, which associate laterally to form flat sheets of varying dimensions that bifurcate and come together to form a honeycomb network within the body of the meniscus. In contrast, the circumferential arrays display a complex network of collagen fibrils arranged into ∼5 μm bundles. Interestingly, both types of architectural organization of collagen fibrils in meniscus are conserved across mammalian species and are age and sex independent. These findings imply that disruptions in meniscal architecture following an injury contribute to poor prognosis for functional repair. © 2010 John Wiley & Sons A/S.
DeSmitt, Holly J; Domire, Zachary J
2016-12-01
Biomechanical models are sensitive to the choice of model parameters. Therefore, determination of accurate subject specific model parameters is important. One approach to generate these parameters is to optimize the values such that the model output will match experimentally measured strength curves. This approach is attractive as it is inexpensive and should provide an excellent match to experimentally measured strength. However, given the problem of muscle redundancy, it is not clear that this approach generates accurate individual muscle forces. The purpose of this investigation is to evaluate this approach using simulated data to enable a direct comparison. It is hypothesized that the optimization approach will be able to recreate accurate muscle model parameters when information from measurable parameters is given. A model of isometric knee extension was developed to simulate a strength curve across a range of knee angles. In order to realistically recreate experimentally measured strength, random noise was added to the modeled strength. Parameters were solved for using a genetic search algorithm. When noise was added to the measurements the strength curve was reasonably recreated. However, the individual muscle model parameters and force curves were far less accurate. Based upon this examination, it is clear that very different sets of model parameters can recreate similar strength curves. Therefore, experimental variation in strength measurements has a significant influence on the results. Given the difficulty in accurately recreating individual muscle parameters, it may be more appropriate to perform simulations with lumped actuators representing similar muscles.
Clark, Toshimasa J; Wilson, Gregory J; Maki, Jeffrey H
2017-07-01
Contrast-enhanced (CE)-MRA optimization involves interactions of sequence duration, bolus timing, contrast recirculation, and both R 1 relaxivity and R2*-related reduction of signal. Prior data suggest superior image quality with slower gadolinium injection rates than typically used. A computer-based model of CE-MRA was developed, with contrast injection, physiologic, and image acquisition parameters varied over a wide gamut. Gadolinium concentration was derived using Verhoeven's model with recirculation, R 1 and R2* calculated at each time point, and modulation transfer curves used to determine injection rates, resulting in optimal resolution and image contrast for renal and carotid artery CE-MRA. Validation was via a vessel stenosis phantom and example patients who underwent carotid CE-MRA with low effective injection rates. Optimal resolution for renal and carotid CE-MRA is achieved with injection rates between 0.5 to 0.9 mL/s and 0.2 to 0.3 mL/s, respectively, dependent on contrast volume. Optimal image contrast requires slightly faster injection rates. Expected signal-to-noise ratio varies with both contrast volume and cardiac output. Simulated vessel phantom and clinical carotid CE-MRA exams at an effective contrast injection rate of 0.4 to 0.5 mL/s demonstrate increased resolution. Optimal image resolution is achieved at intuitively low, effective injection rates (0.2-0.9 mL/s, dependent on imaging parameters and contrast injection volume). Magn Reson Med 78:357-369, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
Chughtai, Morad; McGinn, Tanner; Bhave, Anil; Khan, Sabahat; Vashist, Megha; Khlopas, Anton; Mont, Michael A
2016-11-01
Manipulation under anesthesia (MUA) is performed for knee stiffness following a total knee arthroplasty (TKA) when nonoperative treatments fail. It is important to develop an optimal outpatient physical therapy protocol following an MUA, to avoid a repeat procedure. The purpose of this study was to evaluate and compare: (1) range of motion and (2) the rate of repeat MUA in patients who either underwent innovative multimodal physical therapy (IMMPT) or standard-of-care physical therapy (standard) following an MUA after a TKA. We performed a retrospective database study of patients who underwent an MUA following a TKA between January 2013 to December 2014 ( N = 57). There were 16 (28%) men and 41 (72%) women who had a mean age of 59 years (range, 32-81 years). The patients were stratified into those who underwent IMMPT ( n = 22) and those who underwent standard physical therapy ( n = 35). The 6-month range of motion and rate of repeat manipulation between the two cohorts was analyzed by using Student t-test and Chi-square tests. In addition, we performed a Kaplan-Meier analysis of time to repeat MUA. The IMMPT cohort had a statistically significant higher proportion of TKAs with an optimal range of motion as compared with the standard cohort. There was statistically significant lower proportion of patients who underwent a repeat MUA in the IMMPT as compared with the standard cohort. There was also a significantly lower incidence and longer time to MUA in the IMMPT cohort as compared with the standard cohort in the Kaplan-Meier analysis. The group who underwent IMMPT utilizing Astym therapy had a significantly higher proportion of patients with optimal range of motion, which implies the potential efficacy of this regimen to improve range of motion. Furthermore, the IMMPT cohort had a significantly lower proportion of repeat manipulations as compared with the standard cohort, which implies that an IMMPT approach could potentially reduce the need for a repeat MUA. These findings warrant further investigation into outcomes of different rehab approaches. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Gait during hydrokinesitherapy following total knee arthroplasty.
Giaquinto, Salvatore; Ciotola, Elena; Margutti, Ferdinando
2007-05-15
To obtain gait parameters during hydrotherapy (HT) in patients who were referred for rehabilitation after primary total knee arthroplasty (TKA). The study had a cohort prospective design. Patients who had undergone TKA followed a HT rehabilitation programme. Twenty-two consecutive patients were enrolled. Four of them dropped out for various reasons, independently of HT. Therefore 18 patients could be evaluated (5 men and 13 women). Eighteen age-matched healthy volunteers were the control subjects. Nine patients had a right TKA and nine a left TKA. On the average HT duration was 18.4 days (SD 1.4). The patients presented with a mean speed of 912 (SD 275) meters per hour (m/h) at the baseline. At the last session the mean speed was 1330 (SD 416) m/h. The mean stance duration was 1.75 s (SD 0.34) on the operated side and 1.83 s (SD 0.41) on the non-operated side. By contrast, the mean swing duration was 1.10 s (SD 0.25) on the operated side and 1.13 s (SD 0.34) on the non-operated side. The step duration was the same on both sides. At the beginning of HT the mean stance/swing ratio was 1.94 on the operated side, whereas it was 1.77 on the non-operated side. In the controls the ratio was 1.46. At the beginning the mean stride length was 0.526 m (SD 0.147) and the value became 0.556 (SD 0.138) after 18 training sessions. At the individual level, recovery occurred in a non-linear fashion (Best Fitting, 7th-grade Fourier finite series). The study design permits accurate definition of stride parameters during rehabilitation which allows optimization of the programme. Increase in speed and regain of balance are the main targets of a HT programme and are monitored on a daily basis.
Homsi, R; Gieseke, J; Luetkens, J A; Kupczyk, P; Maedler, B; Kukuk, G M; Träber, F; Agha, B; Rauch, M; Rajakaruna, N; Willinek, W; Schild, H H; Hadizadeh, D R
2016-10-01
To evaluate whether a 3 D proton density-weighted fat-suppressed sequence (PDwFS) of the knee is able to replace multiplanar 2D-PDwFS. 52 patients (26 men, mean age: 41.9 ± 14.5years) underwent magnetic resonance imaging (MRI) of the knee at 3.0 Tesla using a T/R-coil. The imaging protocol included 3 planes of 2D-PDwFS (acquisition time (AT): 6:40 min; voxel sizes: 0.40 - 0.63 × 0.44 - 0.89 × 3mm³) and a 3D-PDwFS (AT: 6:31 min; voxel size: 0.63 × 0.68 × 0.63mm³). Homogeneity of fat suppression (HFS), artifacts, and image sharpness (IS) were evaluated on a 5-point scale (5[excellent] - 1[non-diagnostic]). The sum served as a measure for the overall image quality (OIQ). Contrast ratios (CR) compared to popliteal muscle were calculated for the meniscus (MEN), anterior (ACL) and posterior cruciate ligaments (PCL). In 13 patients who underwent arthroscopic knee surgery, two radiologists evaluated the presence of meniscal, ligamental and cartilage lesions to estimate the sensitivity and specificity of lesion detection. The CR was higher in the ACL, PCL and MEN in 3D- PDwFS compared to 2D-PDwFS (p < 0.01 for ACL and PCL; p = 0.07 for MEN). Compared to 2 D images, the OIQ was rated higher in 3D-PDwFS images (p < 0.01) due to fewer artifacts and HFS despite the lower IS (p < 0.01). The sensitivity and specificity of lesion detection in 3D- and 2D-PDwFS were similar. Compared to standard multiplanar 2D-PDwFS knee imaging, isotropic high spatial resolution 3D-PDwFS of the knee at 3.0 T can be acquired with high image quality in a reasonable scan time. Multiplanar reformations in arbitrary planes may serve as an additional benefit of 3D-PDwFS. • 3D-PDwFS of the knee is acquired with high image quality• 3D-PDwFS can be achieved in only one measurement with a reasonable scan time• 3D-PDwFS with the advantage of multiplanar reformation may replace 2D-PD-weighted knee MRI Citation Format: • Homsi R, Gieseke J, Luetkens JA et al. Three-Dimensional Isotropic Fat-Suppressed Proton Density-Weighted MRI at 3 Tesla Using a T/R-Coil Can Replace Multiple Plane Two-Dimensional Sequences in Knee Imaging. Fortschr Röntgenstr 2016; 188: 949 - 956. © Georg Thieme Verlag KG Stuttgart · New York.
McCarthy, Moira M.; Tucker, Scott; Nguyen, Joseph T.; Green, Daniel W.; Imhauser, Carl W.; Cordasco, Frank A.
2014-01-01
Background Anterior cruciate ligament (ACL) injuries are an increasingly recognized problem in the pediatric population. Unfortunately, outcomes with conservative treatment are extremely poor. Furthermore, adult reconstruction techniques may be inappropriate to treat skeletally immature patients due to the risk of physeal complications. “Physeal-sparing” reconstruction techniques exist but their ability to restore knee stability and contact mechanics is not well understood. Purpose (1) To assess the ability of the all-epiphyseal (AE) and over-the-top (OT) reconstructions to restore knee kinematics; (2) to assess whether these reconstructions decrease the high posterior contact stresses seen with ACL deficiency; (3) to determine whether the AE or OT produce abnormal tibiofemoral contact stresses. Hypothesis The AE reconstruction will restore contact mechanics and kinematics similarly to that of the ACL intact knee. Methods Ten fresh-frozen human cadaveric knees were tested using a robotic manipulator. Tibiofemoral motions were recorded with the ACL intact, after sectioning the ACL, and after both reconstructions in each of the 10 specimens. The AE utilized an all-inside technique with tunnels exclusively within the epiphysis and fixed with suspensory cortical fixation devices. The OT had a central and vertical tibial tunnel with an over-the-top femur position and was fixed with staples and posts on both ends. Anterior stability was assessed with 134N anterior force at 0, 15, 30, 60, and 90° of knee flexion. Rotational stability was assessed with combined 8 Nm and 4 Nm of abduction and internal rotation, respectively, at 5, 15, and 30° of knee flexion. Results Both reconstruction techniques offloaded the posterior aspect of the tibial plateau compared to the ACL deficient knee in response to both anterior loads and combined moments as demonstrated by reduced contact stresses in this region at all flexion angles. Compared to the ACL intact condition, both the AE and OT had increased posteromedial contact stresses in response to anterior load at some flexion angles and the OT had increased peripheral posterolateral contact stresses at 15° in response to combined moments. Neither reconstruction completely restored the mid-joint contact stresses. Both reconstruction techniques restored anterior stability at flexion angles less than or equal to 30°. In contrast, neither reconstruction restored anterior stability at 60 and 90° flexion. Both reconstructions restored coupled anterior translation under combined moments. Additionally, the AE over-constrained internal rotation in response to the combined moments by 12% at 15° flexion. Conclusions Both reconstructions provide anterior and rotational stability, and decrease posterior joint contact stresses compared to the ACL deficient knee. However, neither reconstruction restored the contact mechanics and kinematics of the ACL intact knee. Clinical Relevance Since the AE reconstruction has clinical advantages over the OT, our results support the hypothesis that the new AE technique is a potential candidate for use in the skeletally immature athlete. PMID:23613444
Back, Susan J; Edgar, J Christopher; Canning, Douglas A; Darge, Kassa
2015-09-01
Pediatric contrast-enhanced ultrasound (CEUS) is primarily performed outside the United States where a track record for safety in intravenous and intravesical applications has been established. Contrast-enhanced voiding urosonography (ceVUS) has also been shown to have a much higher rate of vesicoureteral reflux detection compared to voiding cystourethrography. US contrast agents available in the United States differ from those abroad. Optison® (GE Healthcare, Princeton, NJ) is such an US contrast agent. While Optison® has similar characteristics to other second-generation agents, it has never been used for ceVUS. In vitro optimization of dose and imaging parameters as well as assessment of contrast visualization when delivered in conditions similar to ceVUS are necessary starting points prior to in vivo applications. To optimize the intravesical use of Optison® in vitro for ceVUS before its use in pediatric studies. The experimental design simulated intravesical use. Using 9- and 12-MHz linear transducers, we scanned 20-mL syringes varying mechanical index, US contrast agent concentration (0.25%, 0.5%, 1.0%), solvent (saline, urine, radiographic contrast agent) and time out of refrigeration. We evaluated mechanical index settings and contrast duration, optimized the contrast dose, measured the effect of urine and radiographic contrast agent, and the impact of length of time of contrast outside of the refrigerator on US contrast appearance. We scanned 50-ml saline bags to assess the appearance and duration of US contrast with different delivery systems (injection vs. infusion). Consistent contrast visualization was achieved at a mechanical index of 0.06-0.17 and 0.11-0.48 for the L9 and L12 MHz transducers (P < 0.01), respectively. Thus, it was necessary to increase the mechanical index for better contrast visualization of the microbubbles with a higher transducer frequency. The lowest mechanical index for earliest visible microbubble destruction was 0.21 for the 9 MHz and 0.39 for the 12 MHz (P < 0.01) transducers. The 0.5% US contrast agent volume to bladder filling was the most optimal. At this concentration, the mean time to visualize homogenous contrast was 2 min and destruction of approximately half of the microbubbles in the field of view occurred in 7.8 min using the 9-MHz transducer. During contrast infusion, the contrast dose needed to be reduced to 0.12% for maintenance of optimal visualization of microbubbles. There was no deleterious effect on the visualization of contrast in the presence of urine or radiographic contrast agent. Infusion of the US contrast agent speeded visualization of homogeneous enhancement compared with injection. Time outside refrigeration did not affect contrast performance. Transducer mechanical index settings need to be optimized. A very low dose of the US contrast agent Optison® will suffice for intravesical application, i.e. 0.12% to 0.50% of the bladder filling volume. The presence of urine or radiographic contrast agent did not compromise contrast visualization. The best mode of administration is the infusion method due to fast homogenous distribution at the lowest dose of 0.12%. Leaving the US contrast agent outside the refrigerator for an hour does not affect the microbubbles.
Buhagiar, Mark A; Naylor, Justine M; Harris, Ian A; Xuan, Wei; Kohler, Friedbert; Wright, Rachael J; Fortunato, Renee
2013-12-17
Formal rehabilitation programs are often assumed to be required after total knee arthroplasty to optimize patient recovery. Inpatient rehabilitation is a costly rehabilitation option after total knee arthroplasty and, in Australia, is utilized most frequently for privately insured patients. With the exception of comparisons with domiciliary services, no randomized trial has compared inpatient rehabilitation to any outpatient based program. The Hospital Inpatient versus HOme (HIHO) study primarily aims to determine whether 10 days of post-acute inpatient rehabilitation followed by a hybrid home program provides superior recovery of functional mobility on the 6-minute walk test (6MWT) compared to a hybrid home program alone following total knee arthroplasty. Secondarily, the trial aims to determine whether inpatient rehabilitation yields superior recovery in patient-reported function. This is a two-arm parallel randomized controlled trial (RCT), with a third, non-randomized, observational group. One hundred and forty eligible, consenting participants who have undergone a primary total knee arthroplasty at a high-volume joint replacement center will be randomly allocated when cleared for discharge from acute care to either 10 days of inpatient rehabilitation followed by usual care (a 6-week hybrid home program) or to usual care. Seventy participants in each group (140 in total) will provide 80% power at a significance level of 5% to detect an increase in walking capacity from 400 m to 460 m between the Home and Inpatient groups, respectively, in the 6MWT at 6 months post-surgery, assuming a SD of 120 m and a drop-out rate of <10%.The outcome assessor will assess participants at 10, 26 and 52 weeks post-operatively, and will remain blind to group allocation for the duration of the study, as will the statistician. Participant preference for rehabilitation mode stated prior to randomization will be accounted for in the analysis together with any baseline differences in potentially confounding characteristics as required. The HIHO Trial will be the first RCT to investigate the efficacy of inpatient rehabilitation compared to any outpatient alternative following total knee arthroplasty. U.S. National Institutes of Health Clinical Trials Registry (http://clinicaltrials.gov) ref: NCT01583153.
2013-01-01
Background The effectiveness of microprocessor-controlled prosthetic knee joints (MPKs) has been assessed using a variety of outcome measures in a variety of health and health-related domains. However, if the patient is to receive a prosthetic knee joint that enables him to function optimally in daily life, it is vital that the clinician has adequate information about the effects of that particular component on all aspects of persons’ functioning. Especially information concerning activities and participation is of high importance, as this component of functioning closely describes the person’s ability to function with the prosthesis in daily life. The present study aimed to review the outcome measures that have been utilized to assess the effects of microprocessor-controlled prosthetic knee joints (MPK), in comparison with mechanically controlled prosthetic knee joints, and aimed to classify these measures according to the components and categories of functioning defined by the International Classification of Functioning, Disability and Health (ICF). Subsequently, the gaps in the scientific evidence regarding the effectiveness of MPKs were determined. Methods A systematic literature search in 6 databases (i.e. PubMed, CINAHL, Cochrane Library, Embase, Medline and PsychInfo) identified scientific studies that compared the effects of using MPKs with mechanically controlled prosthetic knee joints on persons’ functioning. The outcome measures that have been utilized in those studies were extracted and categorized according to the ICF framework. Also, a descriptive analysis regarding all studies has been performed. Results A total of 37 studies and 72 outcome measures have been identified. The majority (67%) of the outcome measures that described the effects of using an MPK on persons’ actual performance with the prosthesis covered the ICF body functions component. Only 31% of the measures on persons’ actual performance investigated how an MPK may affect performance in daily life. Research also typically focused on young, fit and active persons. Conclusions Scientifically valid evidence regarding the performance of persons with an MPK in everyday life is limited. Future research should specifically focus on activities and participation to increase the understanding of the possible functional added value of MPKs. PMID:24279314
Theeven, Patrick J R; Hemmen, Bea; Brink, Peter R G; Smeets, Rob J E M; Seelen, Henk A M
2013-11-27
The effectiveness of microprocessor-controlled prosthetic knee joints (MPKs) has been assessed using a variety of outcome measures in a variety of health and health-related domains. However, if the patient is to receive a prosthetic knee joint that enables him to function optimally in daily life, it is vital that the clinician has adequate information about the effects of that particular component on all aspects of persons' functioning. Especially information concerning activities and participation is of high importance, as this component of functioning closely describes the person's ability to function with the prosthesis in daily life. The present study aimed to review the outcome measures that have been utilized to assess the effects of microprocessor-controlled prosthetic knee joints (MPK), in comparison with mechanically controlled prosthetic knee joints, and aimed to classify these measures according to the components and categories of functioning defined by the International Classification of Functioning, Disability and Health (ICF). Subsequently, the gaps in the scientific evidence regarding the effectiveness of MPKs were determined. A systematic literature search in 6 databases (i.e. PubMed, CINAHL, Cochrane Library, Embase, Medline and PsychInfo) identified scientific studies that compared the effects of using MPKs with mechanically controlled prosthetic knee joints on persons' functioning. The outcome measures that have been utilized in those studies were extracted and categorized according to the ICF framework. Also, a descriptive analysis regarding all studies has been performed. A total of 37 studies and 72 outcome measures have been identified. The majority (67%) of the outcome measures that described the effects of using an MPK on persons' actual performance with the prosthesis covered the ICF body functions component. Only 31% of the measures on persons' actual performance investigated how an MPK may affect performance in daily life. Research also typically focused on young, fit and active persons. Scientifically valid evidence regarding the performance of persons with an MPK in everyday life is limited. Future research should specifically focus on activities and participation to increase the understanding of the possible functional added value of MPKs.
Rahm, Stefan; Wieser, Karl; Bauer, David E; Waibel, Felix Wa; Meyer, Dominik C; Gerber, Christian; Fucentese, Sandro F
2018-05-16
Most studies demonstrated, that training on a virtual reality based arthroscopy simulator leads to an improvement of technical skills in orthopaedic surgery. However, how long and what kind of training is optimal for young residents is unknown. In this study we tested the efficacy of a standardized, competency based training protocol on a validated virtual reality based knee- and shoulder arthroscopy simulator. Twenty residents and five experts in arthroscopy were included. All participants performed a test including knee -and shoulder arthroscopy tasks on a virtual reality knee- and shoulder arthroscopy simulator. The residents had to complete a competency based training program. Thereafter, the previously completed test was retaken. We evaluated the metric data of the simulator using a z-score and the Arthroscopic Surgery Skill Evaluation Tool (ASSET) to assess training effects in residents and performance levels in experts. The residents significantly improved from pre- to post training in the overall z-score: - 9.82 (range, - 20.35 to - 1.64) to - 2.61 (range, - 6.25 to 1.5); p < 0.001. The overall ASSET score improved from 55 (27 to 84) percent to 75 (48 to 92) percent; p < 0.001. The experts, however, achieved a significantly higher z-score in the shoulder tasks (p < 0.001 and a statistically insignificantly higher z-score in the knee tasks with a p = 0.921. The experts mean overall ASSET score (knee and shoulder) was significantly higher in the therapeutic tasks (p < 0.001) compared to the residents post training result. The use of a competency based simulator training with this specific device for 3-5 h is an effective tool to advance basic arthroscopic skills of resident in training from 0 to 5 years based on simulator measures and simulator based ASSET testing. Therefore, we conclude that this sort of training method appears useful to learn the handling of the camera, basic anatomy and the triangulation with instruments.
Lehecka, B J; Edwards, Michael; Haverkamp, Ryan; Martin, Lani; Porter, Kambry; Thach, Kailey; Sack, Richard J; Hakansson, Nils A
2017-08-01
Gluteal strength plays a role in injury prevention, normal gait patterns, eliminating pain, and enhancing athletic performance. Research shows high gluteal muscle activity during a single-leg bridge compared to other gluteal strengthening exercises; however, prior studies have primarily measured muscle activity with the active lower extremity starting in 90 ° of knee flexion with an extended contralateral knee. This standard position has caused reports of hamstring cramping, which may impede optimal gluteal strengthening. The purpose of this study was to determine which modified position for the single-leg bridge is best for preferentially activating the gluteus maximus and medius. Cross-Sectional. Twenty-eight healthy males and females aged 18-30 years were tested in five different, randomized single-leg bridge positions. Electromyography (EMG) electrodes were placed on subjects' gluteus maximus, gluteus medius, rectus femoris, and biceps femoris of their bridge leg (i.e., dominant or kicking leg), as well as the rectus femoris of their contralateral leg. Subjects performed a maximal voluntary isometric contraction (MVIC) for each tested muscle prior to performing five different bridge positions in randomized order. All bridge EMG data were normalized to the corresponding muscle MVIC data. A modified bridge position with the knee of the bridge leg flexed to 135 ° versus the traditional 90 ° of knee flexion demonstrated preferential activation of the gluteus maximus and gluteus medius compared to the traditional single-leg bridge. Hamstring activation significantly decreased (p < 0.05) when the dominant knee was flexed to 135 ° (23.49% MVIC) versus the traditional 90 ° (75.34% MVIC), while gluteal activation remained similarly high (51.01% and 57.81% MVIC in the traditional position, versus 47.35% and 57.23% MVIC in the modified position for the gluteus maximus and medius, respectively). Modifying the traditional single-leg bridge by flexing the active knee to 135 ° instead of 90 ° minimizes hamstring activity while maintaining high levels of gluteal activation, effectively building a bridge better suited for preferential gluteal activation. 3.
Spahn, G; Schiele, R; Hofmann, G O; Schiltenwolf, M; Grifka, J; Vaitl, T; Schneider, S; Liebers, F; Klinger, H M
2011-04-01
This metaanalysis was performed to evaluate the prevalence of the radiological assessed knee osteoarthritis in the whole community. Medical databases (Medline, EMBASE, Cochrane) were searched for the strategy: ["Osteoarthritis" and "Knee" and "Prevalence"]. The deadline for the search was 31.12.2009. Two investigators (first and senior author) independently made the selection from 17 studies (from a total of 1428) according to the inclusion criteria: a cross-sectional study of the whole community, radiological investigation and definition of knee ROA by an established radiological score. Only studies in English or German language were evaluated. Effect sizes (event rate, odds ratio [OR] and confidence interval [CI]) were calculated by the software "Comprehensive Metaanalysis V2". Study heterogeneity (I2) was determined accordingly to Higgins. The kappa index for interobserver validity was k = 0.948. All studies judged the grade of osteoarthritis according to the Kellgren-Lawrence (KL) score. For calculation of knee ROA KL grades 2+ were estimated only. The total prevalence of knee ROA was 24.3 % (CI 23.4-25.2 %). The whole prevalence in male patients was 24.3 % (CI 23.4-25.2 %); I2 = 59.4 (p = 0.002) and in female patients 32.6 % (CI 31.8-33.4 %); I2 = 49,1 (p < 0.001). Younger male patients (age 50-) had a prevalence of 5.6 (CI 4.5-6.8). In older patients (80+) the male prevalence was 44.5 % (CI 39.6-49.5 %). In this age group female patients had a prevalence of 71.6 % (CI 67.6-75.3 %). The higher prevalence of knee ROA in female patients was significant (OR = 1.8 [1.7-1.9]; I2 = 46.0 [p < 0.001]). The prevalence of knee ROA was higher in male Asians compared with male Caucasians (OR = 1.1, CI 0.9-1.2; p = 0.080) in tendency. This difference was significant in female patients (OR = 2.2; CI 2.0-2.4; p < 0.001). Furthermore another trend was evaluated. Female patients (70-79 years) from the birth-year cohort 1920- had a prevalence of 37.8 % (CI 35.9-39.7)%. In contrast female patients from the birth-year cohort 1920 had a prevalence of 62.8 % (CI 60.8-64.8 %) at 70-79 years. This difference was significant (OR = 2.8; CI 2.5-3.1; p < 0.001). This investigation confirms the high prevalence of knee ROA. The evaluated data may serve as a reference for medical or scientific investigations in the future. © Georg Thieme Verlag KG Stuttgart · New York.
Müller-Horvat, C; Schick, F; Claussen, C D; Grönewäller, E
2004-12-01
To evaluate the suitability of different MR sequences for monitoring the stage of maturation of hyaline cartilage grafts in the knee joint and the early detection of complications like hypertrophy. In addition, it was analyzed whether indirect MR arthrography can indicate debonding of the graft. MRI examinations were performed in 19 patients, aged 17 - 48 years, with autologous transplantation of a hyaline cartilage tissue graft after knee trauma. Examination dates were prior to transplantation to localize the defect, and 6 weeks, 3, 6 and 12 months after transplantation to control morphology and maturation of the autologous graft. Standard T2- and proton-density-weighted turbo spin echo (TSE) sequences and T1-weighted spin echo (SE) sequences were used, as well as gradient echo (GRE) sequences with and without magnetization transfer (MT) prepulses. In some cases, indirect MR arthrography was performed. Cartilage defect and the hyaline cartilage graft could be detected in all 19 patients. Hypertrophy of the graft could be found early in 3 patients and debonding in 1 patient. For depicting the graft a short time after surgery, T2-weighted TSE-sequences showed the best results. Six and 12 months after transplantation, spoiled 3D-GRE-sequences like FLASH3D (fast low angle shot) showed reduced artifacts due to magnetic residues from the surgery. Difference images from GRE-sequences with and without MT pulse provided high contrast between cartilage and surrounding tissue. The quantification of the MT effect showed an assimilation of the graft to the original cartilage within 12 months. Indirect MR arthrography showed subchondral contrast medium even 12 months after transplantation in 3 patients. MRI allows a reliable depiction of the hyaline graft and provides very early detection of complications like hypertrophy. The MT effect seems to be correlated with maturation of the graft and allows selective depiction of normal cartilage and engrafted cartilage.
Elimination of motion and pulsation artifacts using BLADE sequences in knee MR imaging.
Lavdas, Eleftherios; Mavroidis, Panayiotis; Hatzigeorgiou, Vasiliki; Roka, Violeta; Arikidis, Nikos; Oikonomou, Georgia; Andrianopoulos, Konstantinos; Notaras, Ioannis
2012-10-01
The purpose of this study is to evaluate the ability of proton density (PD)-BLADE sequences in reducing or even eliminating motion and pulsatile flow artifacts in knee magnetic resonance imaging examinations. Eighty consecutive patients, who had been routinely scanned for knee examination, participated in the study. The following pairs of sequences with and without BLADE were compared: (a) PD turbo spin echo (TSE) sagittal (SAG) fat saturation (FS) in 35 patients, (b) PD TSE coronal (COR) FS in 19 patients, (c) T2 TSE axial in 13 patients and (d) PD TSE SAG in 13 patients. Both qualitative and quantitative analyses were performed based on the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and relative contrast (ReCon) measures of normal anatomic structures. The qualitative analysis was performed by experienced radiologists. Also, the presence of image motion and pulsation artifacts was evaluated. Based on the results of the SNR, CRN and ReCon for the different sequences and anatomical structures, the BLADE sequences were significantly superior in 19 cases, whereas the corresponding conventional sequences were significantly superior in only 6 cases. BLADE sequences eliminated motion artifacts in all the cases. However, motion artifacts were shown in (a) six PD TSE SAG FS, (b) three PD TSE COR FS, (c) three PD TSE SAG and (d) two T2 TSE axial conventional sequences. In our results, it was found that, in PD FS sequences (sagittal and coronal), the differences between the BLADE and conventional sequences regarding the elimination of motion and pulsatile flow artifacts were statistically significant. In all the comparisons, the PD FS BLADE sequences (coronal and sagittal) were significantly superior to the corresponding conventional sequences regarding the classification of their image quality. In conclusion, this technique appears to be capable to potentially eliminate motion and pulsatile flow artifacts in MR images. Copyright © 2012 Elsevier Inc. All rights reserved.
Gustafson, Jonathan A; Gorman, Shannon; Fitzgerald, G Kelley; Farrokhi, Shawn
2016-01-01
Increased walking knee joint stiffness has been reported in patients with knee osteoarthritis (OA) as a compensatory strategy to improve knee joint stability. However, presence of episodic self-reported knee instability in a large subgroup of patients with knee OA may be a sign of inadequate walking knee joint stiffness. The objective of this work was to evaluate the differences in walking knee joint stiffness in patients with knee OA with and without self-reported instability and examine the relationship between walking knee joint stiffness with quadriceps strength, knee joint laxity, and varus knee malalignment. Overground biomechanical data at a self-selected gait velocity was collected for 35 individuals with knee OA without self-reported instability (stable group) and 17 individuals with knee OA and episodic self-reported instability (unstable group). Knee joint stiffness was calculated during the weight-acceptance phase of gait as the change in the external knee joint moment divided by the change in the knee flexion angle. The unstable group walked with lower knee joint stiffness (p=0.01), mainly due to smaller heel-contact knee flexion angles (p<0.01) and greater knee flexion excursions (p<0.01) compared to their knee stable counterparts. No significant relationships were observed between walking knee joint stiffness and quadriceps strength, knee joint laxity or varus knee malalignment. Reduced walking knee joint stiffness appears to be associated with episodic knee instability and independent of quadriceps muscle weakness, knee joint laxity or varus malalignment. Further investigations of the temporal relationship between self-reported knee joint instability and walking knee joint stiffness are warranted. Copyright © 2015 Elsevier B.V. All rights reserved.
Gustafson, Jonathan A.; Gorman, Shannon; Fitzgerald, G. Kelley; Farrokhi, Shawn
2017-01-01
Increased walking knee joint stiffness has been reported in patients with knee osteoarthritis (OA) as a compensatory strategy to improve knee joint stability. However, presence of episodic self-reported knee instability in a large subgroup of patients with knee OA may be a sign of inadequate walking knee joint stiffness. The objective of this work was to evaluate the differences in walking knee joint stiffness in patients with knee OA with and without self-reported instability and examine the relationship between walking knee joint stiffness with quadriceps strength, knee joint laxity, and varus knee malalignment. Overground biomechanical data at a self-selected gait velocity was collected for 35 individuals with knee OA without self-reported instability (stable group) and 17 individuals with knee OA and episodic self-reported instability (unstable group). Knee joint stiffness was calculated during the weight-acceptance phase of gait as the change in the external knee joint moment divided by the change in the knee flexion angle. The unstable group walked with lower knee joint stiffness (p=0.01), mainly due to smaller heel-contact knee flexion angles (p<0.01) and greater knee flexion excursions (p<0.01) compared to their knee stable counterparts. No significant relationships were observed between walking knee joint stiffness and quadriceps strength, knee joint laxity or varus knee malalignment. Reduced walking knee joint stiffness appears to be associated with episodic knee instability and independent of quadriceps muscle weakness, knee joint laxity or varus malalignment. Further investigations of the temporal relationship between self-reported knee joint instability and walking knee joint stiffness are warranted. PMID:26481256
Evolutionary Bi-objective Optimization for Bulldozer and Its Blade in Soil Cutting
NASA Astrophysics Data System (ADS)
Sharma, Deepak; Barakat, Nada
2018-02-01
An evolutionary optimization approach is adopted in this paper for simultaneously achieving the economic and productive soil cutting. The economic aspect is defined by minimizing the power requirement from the bulldozer, and the soil cutting is made productive by minimizing the time of soil cutting. For determining the power requirement, two force models are adopted from the literature to quantify the cutting force on the blade. Three domain-specific constraints are also proposed, which are limiting the power from the bulldozer, limiting the maximum force on the bulldozer blade and achieving the desired production rate. The bi-objective optimization problem is solved using five benchmark multi-objective evolutionary algorithms and one classical optimization technique using the ɛ-constraint method. The Pareto-optimal solutions are obtained with the knee-region. Further, the post-optimal analysis is performed on the obtained solutions to decipher relationships among the objectives and decision variables. Such relationships are later used for making guidelines for selecting the optimal set of input parameters. The obtained results are then compared with the experiment results from the literature that show a close agreement among them.
Nam, Denis; Vajapey, Sravya; Nunley, Ryan M; Barrack, Robert L
2016-10-01
The optimal coronal alignment after total knee arthroplasty (TKA) has become an area of increased debate. Sources of variability among investigations include the radiographic technique used for both preoperative surgical planning and postoperative alignment assessments. This study's purpose was to assess the impact of the imaging modality used on the measurement of coronal plane alignment after TKA. A consecutive series of patients undergoing TKA using the same cruciate-retaining prosthesis were included for analysis. Postoperatively, all patients received both a rotationally controlled, scout computed tomography scan and a hip-knee-ankle (HKA) image using the EOS Imaging system (EOS Inc., Paris, France). Two, independent observers measured the HKA angle, and femoral and tibial component alignment from each image. After classifying overall and component alignment as neutral, varus, or valgus, 40.6% (65 of 160) of knees had a discordant alignment classification for HKA, 28.1% (45 of 160) for femoral component alignment, and 26.9% (43 of 160) for tibial component alignment between their computed tomography and EOS images. Overall, 24.4% (39 of 160) of patients had a HKA difference of ≥3° between the 2 images, whereas 18.8% (30 of 160) and 20.0% (32 of 160) of patients had a femoral and tibial component alignment difference of ≥2°, respectively. Significant differences are present when comparing 2 measurement techniques of mechanical alignment after TKA. The impact of imaging modality on postoperative assessments must be accounted for and be consistent when comparing the results of different investigations. Copyright © 2016 Elsevier Inc. All rights reserved.
Ali, Azhar A; Shalhoub, Sami S; Cyr, Adam J; Fitzpatrick, Clare K; Maletsky, Lorin P; Rullkoetter, Paul J; Shelburne, Kevin B
2016-01-25
Healthy patellofemoral (PF) joint mechanics are critical to optimal function of the knee joint. Patellar maltracking may lead to large joint reaction loads and high stresses on the articular cartilage, increasing the risk of cartilage wear and the onset of osteoarthritis. While the mechanical sources of PF joint dysfunction are not well understood, links have been established between PF tracking and abnormal kinematics of the tibiofemoral (TF) joint, specifically following cruciate ligament injury and repair. The objective of this study was to create a validated finite element (FE) representation of the PF joint in order to predict PF kinematics and quadriceps force across healthy and pathological specimens. Measurements from a series of dynamic in-vitro cadaveric experiments were used to develop finite element models of the knee for three specimens. Specimens were loaded under intact, ACL-resected and both ACL and PCL-resected conditions. Finite element models of each specimen were constructed and calibrated to the outputs of the intact knee condition, and subsequently used to predict PF kinematics, contact mechanics, quadriceps force, patellar tendon moment arm and patellar tendon angle of the cruciate resected conditions. Model results for the intact and cruciate resected trials successfully matched experimental kinematics (avg. RMSE 4.0°, 3.1mm) and peak quadriceps forces (avg. difference 5.6%). Cruciate resections demonstrated either increased patellar tendon loads or increased joint reaction forces. The current study advances the standard for evaluation of PF mechanics through direct validation of cruciate-resected conditions including specimen-specific representations of PF anatomy. Copyright © 2015 Elsevier Ltd. All rights reserved.
Abate, Michele; Vanni, Daniele; Pantalone, Andrea; Salini, Vincenzo
2017-02-01
To evaluate the therapeutic trajectory of intra-articular injections of hyaluronic acid at high concentration (2%) performed at 4-month intervals. Subjects with knee osteoarthritis received, after a weekly injection of 32 mg/2 mL hyaluronic acid for 3 weeks, a single injection of 50 mg/2.5 mL hyaluronic acid (not cross-linked, molecular weight 800-1200 kDa) at 4-month interval (4, 8 and 12 months). Clinical assessment (visual analogic scale [VAS] for pain at rest and during activities, Lequesne Index [LI], Knee Injury and Osteoarthritis Outcome Score (KOOS), and monthly non-steroidal anti-inflammatory drug consumption) was performed at baseline, and after 1, 4, 6, 8, 12 and 14 months. In the 15 knees treated, pain decreased (baseline vs. 14 months: VAS at rest, 3.7 ± 1.7 vs. 1 ± 0.7 [P < 0.000]; VAS activities, 6.2 ± 1.7 vs. 2.6 ± 1.3 [P < 0.000]) and function improved (baseline vs. 14 months: KOOS, 51.9 ± 15.3 vs. 70.2 ± 13.7 [P < 0.000]; LI, 10 ± 3.8 vs. 5.4 ± 2.4 [P < 0.000]) significantly. This schedule provides persistent positive results in terms of reduced pain and improved function, optimizing the protective properties of the hyaluronic acid used. © 2015 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.
Analysis of functional outcome of Hoffa fractures: A retrospective review of 32 patients.
Trikha, Vivek; Das, Saubhik; Gaba, Sahil; Agrawal, Prabhat
2017-01-01
Hoffa fractures are uncommon intra-articular fractures of femoral condyle in coronal plane. The purpose of our study is to assess radiologic and functional outcome in operatively treated Hoffa fractures. We retrospectively reviewed 32 patients of isolated Hoffa fracture from January 2010 to March 2015. All were treated with open reduction and internal fixation using lateral approach for lateral Hoffa and medial approach for medial Hoffa fracture. Cancellous screws in lag mode and/or antiglide plate were employed for fixation in accordance with fracture anatomy. All patients were subjected to aggressive physical therapy postoperatively. Knee Society Score (KSS), International Knee Documentation Committee Score (IKDC), and Knee range of motion (ROM) were documented at final follow-up for functional evaluation. All fractures united by mean time of 11.56 ± 1.5 weeks. No evidence of subsequent displacement or fixation failure, arthritis, Avascular necrosis (AVN) of femoral condyle was elicited in any of the patients. Documented mean KSS and mean IKDC Score at final follow-up were 83.19 ± 8.43 and 81.62± 6.95, respectively. ROM at final follow-up was ranging from 0° to mean 116.41° ± 13.98°. Complications included stiffness of the involved knee in four patients, including one patient who developed infection and had to undergo implant removal after fracture union. Operative treatment of Hoffa fractures yields fairly good functional outcome. One must endeavor to achieve adequate intraoperative exposure and stable congruous articular reconstruction. Early aggressive physical therapy is a harbinger of optimal outcome.
Hu, Jingwen; Klinich, Kathleen D; Reed, Matthew P; Kokkolaras, Michael; Rupp, Jonathan D
2012-06-01
In motor-vehicle crashes, young school-aged children restrained by vehicle seat belt systems often suffer from abdominal injuries due to submarining. However, the current anthropomorphic test device, so-called "crash dummy", is not adequate for proper simulation of submarining. In this study, a modified Hybrid-III six-year-old dummy model capable of simulating and predicting submarining was developed using MADYMO (TNO Automotive Safety Solutions). The model incorporated improved pelvis and abdomen geometry and properties previously tested in a modified physical dummy. The model was calibrated and validated against four sled tests under two test conditions with and without submarining using a multi-objective optimization method. A sensitivity analysis using this validated child dummy model showed that dummy knee excursion, torso rotation angle, and the difference between head and knee excursions were good predictors for submarining status. It was also shown that restraint system design variables, such as lap belt angle, D-ring height, and seat coefficient of friction (COF), may have opposite effects on head and abdomen injury risks; therefore child dummies and dummy models capable of simulating submarining are crucial for future restraint system design optimization for young school-aged children. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.
Timing of Re-Transfusion Drain Removal Following Total Knee Replacement
Leeman, MF; Costa, ML; Costello, E; Edwards, D
2006-01-01
INTRODUCTION The use of postoperative drains following total knee replacement (TKR) has recently been modified by the use of re-transfusion drains. The aim of our study was to investigate the optimal time for removal of re-transfusion drains following TKR. PATIENTS AND METHODS The medical records of 66 patients who had a TKR performed between October 2003 and October 2004 were reviewed; blood drained before 6 h and the total volume of blood drained was recorded. RESULTS A total of 56 patients had complete records of postoperative drainage. The mean volume of blood collected in the drain in the first 6 h was 442 ml. The mean total volume of blood in the drain was 595 ml. Therefore, of the blood drained, 78% was available for transfusion. CONCLUSION Re-transfusion drains should be removed after 6 h, when no further re-transfusion is permissible. PMID:16551400
Anatomical Individualized ACL Reconstruction.
Rahnemai-Azar, Amir Ata; Sabzevari, Soheil; Irarrázaval, Sebastián; Chao, Tom; Fu, Freddie H
2016-10-01
The anterior cruciate ligament (ACL) is composed of two bundles, which work together to provide both antero-posterior and rotatory stability of the knee. Understanding the anatomy and function of the ACL plays a key role in management of patients with ACL injury. Anatomic ACL reconstruction aims to restore the function of the native ACL. Femoral and tibial tunnels should be placed in their anatomical location accounting for both the native ACL insertion site and bony landmarks. One main component of anatomical individualized ACL reconstruction is customizing the treatment according to each patient's individual characteristics, considering preoperative and intraoperative evaluation of the native ACL and knee bony anatomy. Anatomical individualized reconstruction surgery should also aim to restore the size of the native ACL insertion as well. Using this concept, while single bundle ACL reconstruction can restore the function of the ACL in some patients, double bundle reconstruction is indicated in others to achieve optimal outcome.
Bahraminasab, Marjan; Farahmand, Farzam
2017-09-01
The trend in biomaterials development has now headed for tailoring the properties and making hybrid materials to achieve the optimal performance metrics in a product. Modern manufacturing processes along with advanced computational techniques enable systematical fabrication of new biomaterials by design strategy. Functionally graded materials as a recent group of hybrid materials have found numerous applications in biomedical area, particularly for making orthopedic prostheses. This article, therefore, seeks to address the following research questions: (RQ1) What is the desired structure of orthopedic hybrid materials? (RQ2) What is the contribution of the literature in the development of hybrid materials in the field of orthopedic research? (RQ3) Which type of manufacturing approaches is prevalently used to build these materials for knee and hip implants? (RQ4) Is there any inadequacy in the methods applied?
Chang, Gregory; Wiggins, Graham C.; Xia, Ding; Lattanzi, Riccardo; Madelin, Guillaume; Raya, Jose G.; Finnerty, Matthew; Fujita, Hiroyuki; Recht, Michael P.; Regatte, Ravinder R.
2011-01-01
Purpose To compare a new birdcage-transmit, 28 channel-receive array (28 Ch) coil and a quadrature volume coil for 7 Tesla morphologic MRI and T2 mapping of knee cartilage. Methods The right knees of ten healthy subjects were imaged on a 7 Tesla whole body MR scanner using both coils. 3-dimensional fast low-angle shot (3D-FLASH) and multi-echo spin-echo (MESE) sequences were implemented. Cartilage signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), thickness, and T2 values were assessed. Results SNR/CNR was 17–400% greater for the 28 Ch compared to the quadrature coil (p≤0.005). Bland-Altman plots show mean differences between measurements of tibial/femoral cartilage thickness and T2 values obtained with each coil to be small (−0.002±0.009 cm/0.003±0.011 cm) and large (−6.8±6.7 ms/−8.2±9.7 ms), respectively. For the 28 Ch coil, when parallel imaging with acceleration factors (AF) 2, 3, and 4 was performed, SNR retained was: 62–69%, 51–55%, and 39–45%. Conclusion A 28 Ch knee coil provides increased SNR/CNR for 7T cartilage morphologic imaging and T2 mapping. Coils should be switched with caution during clinical studies because T2 values may differ. The greater SNR of the 28 Ch coil could be used to perform parallel imaging with AF2 and obtain similar SNR as the quadrature coil. PMID:22095723
Muscle mechanical advantage of human walking and running: implications for energy cost.
Biewener, Andrew A; Farley, Claire T; Roberts, Thomas J; Temaner, Marco
2004-12-01
Muscular forces generated during locomotion depend on an animal's speed, gait, and size and underlie the energy demand to power locomotion. Changes in limb posture affect muscle forces by altering the mechanical advantage of the ground reaction force (R) and therefore the effective mechanical advantage (EMA = r/R, where r is the muscle mechanical advantage) for muscle force production. We used inverse dynamics based on force plate and kinematic recordings of humans as they walked and ran at steady speeds to examine how changes in muscle EMA affect muscle force-generating requirements at these gaits. We found a 68% decrease in knee extensor EMA when humans changed gait from a walk to a run compared with an 18% increase in hip extensor EMA and a 23% increase in ankle extensor EMA. Whereas the knee joint was extended (154-176 degrees) during much of the support phase of walking, its flexed position (134-164 degrees) during running resulted in a 5.2-fold increase in quadriceps impulse (time-integrated force during stance) needed to support body weight on the ground. This increase was associated with a 4.9-fold increase in the ground reaction force moment about the knee. In contrast, extensor impulse decreased 37% (P < 0.05) at the hip and did not change at the ankle when subjects switched from a walk to a run. We conclude that the decrease in limb mechanical advantage (mean limb extensor EMA) and increase in knee extensor impulse during running likely contribute to the higher metabolic cost of transport in running than in walking. The low mechanical advantage in running humans may also explain previous observations of a greater metabolic cost of transport for running humans compared with trotting and galloping quadrupeds of similar size.
[SOMATOTYPE JOINT MOBILITY AND RANGES OF HIP AND KNEE OF COLLEGE STUDENTS].
Godoy-Cumillaf, Andrés; Valdés-Badilla, Pablo; García Sandoval, Alan; Grandón Fuentes, Monica; Lagos Del Canto, Loreto; Aravena Turra, Raúl; Herrera-Valenzuela, Tomás; Bruneau Chavez, José; Durán Agüero, Samuel
2015-12-01
several studies indicate a consistency between the physical inactivity and low levels of mobility in hip and knee joint. to determine the differences in the motion range of the hip and knee joint between the different classifications of somatotype in students of Pedagogy in Physical Education of the Universidad Autónoma de Chile, campus Temuco. the sample included 102 physical education students (31.3% female), somatotype was obtained through the protocol of the International Society for the Advancement of Kinanthropometry (ISAK) and the motion range of the hip and knee joint (ROM) using a universal goniometer. the mean somatotype was endo-mesomorphic (4.8 - 3.4 - 2) for the women and meso-endomorphic (3.5 - 5.7 - 2) for the males, while the ROM evaluation indicated that the 50% of the students presented mobility values of joint lower than the normal ones. Furthermore, the endo-mesomorphic women showed lower ROM values of medial rotation of the right hip (45.5 ° ± 10.2 °; P = 0.0125, t = 2.732) and left hip side rotation (41.7 ° ± 10.3 °; P = 0.0256; p = 2.402) than the women meso-endomorphic. the results shows a relationship between the somatotype and hip ROM in the women, showing that in the women the most favorable results of joint mobility are related with a greater muscle mass. In contrasts, no significant differences were observed in men. It is important to encourage the development of joint mobility exercises according to the specific needs of each sex. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Jakobsen, Markus Due; Sundstrup, Emil; Andersen, Christoffer H; Aagaard, Per; Andersen, Lars L
2013-02-01
The present study's aim was to evaluate muscle activity during leg exercises using elastic vs. isoinertial resistance at different exertion and loading levels, respectively. Twenty-four women and eighteen men aged 26-67 years volunteered to participate in the experiment. Electromyographic (EMG) activity was recorded in nine muscles during a standardized forward lunge movement performed with dumbbells and elastic bands during (1) ballistic vs. controlled exertion, and (2) at low, medium and high loads (33%, 66% and 100% of 10 RM, respectively). The recorded EMG signals were normalized to MVC EMG. Knee joint angle was measured using electronic inclinometers. The following results were obtained. Loading intensity affected EMG amplitude in the order: low
Quantitative Mapping of Human Cartilage at 3.0T
Wang, Ligong; Regatte, Ravinder R.
2014-01-01
Rationale and Objectives The objectives of this study were to measure the parallel changes of transverse relaxation times (T2), spin-lattice relaxation time in the rotating frame (T1ρ), and the delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC)-T1 mapping of human knee cartilage in detecting cartilage degeneration at 3.0T. Materials and Methods Healthy volunteers (n = 10, mean age 35.6 years) and patients (n = 10, mean age 65 years) with early knee osteoarthritis (OA) were scanned at 3.0T MR using an 8-channel phased array knee coil (transmit–receive). Quantitative assessment of T2, T1ρ, and dGEMRIC-T1 values (global and regional) were correlated between asymptomatic subjects and patients with OA. Results The average T2 (39 ± 2 milliseconds [mean ± standard deviation] vs. 47 ± 6 milliseconds, P < .0007) and T1ρ (48 ± 3 vs. 62 ± 8 milliseconds, P < .0002) values were all markedly increased in all patients with OA when compared to healthy volunteers. The average dGEMRIC-T1 (1244 ± 134 vs. 643 ± 227 milliseconds, P < .000002) value was sharply decreased after intravenous administration of gadolinium contrast agent in all patients with OA. Conclusions The research results showed that all the T2, T1ρ, and dGEMRIC-T1 relaxation times varied with the cartilage degeneration. The dGEMRIC-T1 and T1ρ relaxation times seem to be more sensitive than T2 in detecting early cartilage degeneration. The preliminary study demonstrated that the early biochemical changes in knee osteoarthritic patients could be detected noninvasively in in vivo using T1ρ and dGEMRIC-T1 mapping. PMID:24594416
The functional significance of hamstrings composition: is it really a "fast" muscle group?
Evangelidis, Pavlos E; Massey, Garry J; Ferguson, Richard A; Wheeler, Patrick C; Pain, Matthew T G; Folland, Jonathan P
2017-11-01
Hamstrings muscle fiber composition may be predominantly fast-twitch and could explain the high incidence of hamstrings strain injuries. However, hamstrings muscle composition in vivo, and its influence on knee flexor muscle function, remains unknown. We investigated biceps femoris long head (BFlh) myosin heavy chain (MHC) composition from biopsy samples, and the association of hamstrings composition and hamstrings muscle volume (using MRI) with knee flexor maximal and explosive strength. Thirty-one young men performed maximal (concentric, eccentric, isometric) and explosive (isometric) contractions. BFlh exhibited a balanced MHC distribution [mean ± SD (min-max); 47.1 ± 9.1% (32.6-71.0%) MHC-I, 35.5 ± 8.5% (21.5-60.0%) MHC-IIA, 17.4 ± 9.1% (0.0-30.9%) MHC-IIX]. Muscle volume was correlated with knee flexor maximal strength at all velocities and contraction modes (r = 0.62-0.76, P < 0.01), but only associated with late phase explosive strength (time to 90 Nm; r = -0.53, P < 0.05). In contrast, BFlh muscle composition was not related to any maximal or explosive strength measure. BFlh MHC composition was not found to be "fast", and therefore composition does not appear to explain the high incidence of hamstrings strain injury. Hamstrings muscle volume explained 38-58% of the inter-individual differences in knee flexor maximum strength at a range of velocities and contraction modes, while BFlh muscle composition was not associated with maximal or explosive strength. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Jones, Michael D; Tran, Charles W; Li, Guang; Maksymowych, Walter P; Zernicke, Ronald F; Doschak, Michael R
2010-09-01
To determine whether treatment with an antiresorptive drug in combination with an antiinflammatory drug reduces periarticular bone and soft tissue adaptations associated with the progression of posttraumatic secondary osteoarthritis (OA). We used in vivo microfocal computed tomography (micro-CT) to map bony adaptations and in vivo micro-magnetic resonance imaging (micro-MRI) to examine joint inflammation in a rat model of surgically induced OA secondary to knee triad injury. We examined the arthroprotective effects of the bisphosphonates alendronate and risedronate and the nonsteroidal antiinflammatory drug (NSAID) meloxicam. Micro-CT revealed reduced levels of periarticular trabecular bone loss in animals with knee triad injury treated with the bisphosphonate drugs alendronate or risedronate, or the NSAID meloxicam, compared with untreated animals. Alendronate treatment reduced bony osteophyte development. While risedronate as a monotherapy did not positively impact osteophytogenesis, combination therapy with risedronate and meloxicam reduced osteophyte severity somewhat. Micro-MRI revealed an increased, diffuse water signal in the epiphyses of untreated rats with knee triad injury 8 weeks after surgery, suggestive of a bone marrow lesion-like stimulus. In contrast, meloxicam-treated rats showed a significant reduction in fluid signal compared with both bisphosphonate-treated groups 8 weeks after surgery. Histologic analysis qualitatively confirmed the chondroprotective effect of both bisphosphonate treatments, showing fewer degradative changes compared with untreated rats with knee triad injury. Our findings indicate that select combinations of bisphosphonate and NSAID drug therapy in the early stages of secondary OA preserve trabecular bone mass and reduce the impact of osteophytic bony adaptations and bone marrow lesion-like stimulus. Bisphosphonate and NSAID therapy may be an effective disease-modifying drug regimen if administered early after the initial injury.
Potter, P J; Kirby, R L
1991-12-01
The effect of simulated bilateral knee-flexion contractures (KFC) on the electromyographic (EMG) activity of the vastus lateralis was studied by testing 10 normal subjects using surface EMG to test the hypothesis that the activity of the knee extensors would increase as a function of the severity of the contracture. The root mean square of the EMG activity was determined from four 4-s samples taken at 30-s intervals, during 2 min of standing in each of five positions of simulated KFC (0 degree, 10 degrees, 20 degrees, 30 degrees and 40 degrees). A randomly balanced order of conditions was used. KFC were simulated in each subject by means of an adjustable line from the subject's waist to the sole of each foot. An analysis of variance was used to contrast EMG activity, and a significant difference was found between each of the positions (P less than 0.05). The mean (+/- 1 SD) EMG activity, expressed as a percentage of the maximum voluntary contraction, was 0.3% (+/- 0.2) at 0 degree, 7.6% (+/- 5.6) at 10 degrees, 10.9% (+/- 7.6) at 20 degrees, 16.6% (+/- 12.4) at 30 degrees and 24.0% (+/- 14.0) at 40 degrees. A linear relationship was found (r2 = 0.986), expressed by the equation y = 0.62 + 0.56 x, where y represents EMG activity and x represents the extent of simulated KFC (P = 0.0007). The results provide insight into the increased knee extensor activity necessary to stand with KFC and underline the importance of treating this common disorder.
García-García, Oscar; Serrano-Gómez, Virginia; Hernández-Mendo, Antonio; Tapia-Flores, Antonio
2016-06-01
The aim of this study was to monitor in-season changes in the mechanical and neuromuscular characteristics of knee extensor and flexor muscles in professional soccer players. Twenty-one professional soccer players (soccer group, or SG) and sixteen non-soccer playing males (non-soccer group, or NSG) were assessed by tensiomyography on two occasions: just after the start of the competitive season and 10 weeks later. During this time the soccer players' training sessions were built mainly on speed and strength drills. Mixed-design factorial analysis of variance was conducted and effect sizes were calculated. There was a significant interaction between time (assessment points) x group (SG vs. NSG) x muscle for contraction time (Tc), maximum radial muscle displacement (Dm), and delay time (Td). In the case of the knee extensors, after 10 weeks, there was a 17.7%-22.7% decrease in Tc, an 8.7%-9.9% decrease in Td, and a 12.2%-14.2% decrease in Dm knee extensor in the SG (P<0.01), with a large effect size. In the case of the knee flexors, by contrast, there was an 11.9% increase in Td and a 24.5% increase in Dm (P<0.01), with a moderate to large effect size. The findings confirm that mechanical and neuromuscular characteristics change over time and also vary according to the characteristics of the athlete (SG vs. NSG) and the muscle analyzed. In conclusion, soccer coaches could use Tc, Td, and Dm data to individualize work load and intensity and control the effects of neuromuscular training throughout the season using a portable, non-invasive technique that, unlike stress tests, does not cause fatigue and therefore does not interfere with training periodization.
Carlson, Victor R; Sheehan, Frances T; Shen, Aricia; Yao, Lawrence; Jackson, Jennifer N; Boden, Barry P
2017-07-01
The tibial tubercle to trochlear groove (TT-TG) distance is used for screening patients with a variety of patellofemoral joint disorders to determine who may benefit from patellar medialization using a tibial tubercle osteotomy. Clinically, the TT-TG distance is predominately based on static imaging with the knee in full extension; however, the predictive ability of this measure for dynamic patellar tracking patterns is unknown. To determine whether the static TT-TG distance can predict dynamic lateral displacement of the patella. Cohort study (Diagnosis); Level of evidence, 2. The static TT-TG distance was measured at full extension for 70 skeletally mature subjects with (n = 32) and without (n = 38) patellofemoral pain. The dynamic patellar tracking patterns were assessed from approximately 45° to 0° of knee flexion by use of dynamic cine-phase contrast magnetic resonance imaging. For each subject, the value of dynamic lateral tracking corresponding to the exact knee angle measured in the static images for that subject was identified. Linear regression analysis determined the predictive ability of static TT-TG distance for dynamic patellar lateral displacement for each cohort. The static TT-TG distance measured with the knee in full extension cannot accurately predict dynamic lateral displacement of the patella. There was weak predictive ability among subjects with patellofemoral pain ( r 2 = 0.18, P = .02) and no predictive capability among controls. Among subjects with patellofemoral pain and static TT-TG distances 15 mm or more, 8 of 13 subjects (62%) demonstrated neutral or medial patellar tracking patterns. The static TT-TG distance cannot accurately predict dynamic lateral displacement of the patella. A large percentage of patients with patellofemoral pain and pathologically large TT-TG distances may have neutral to medial maltracking patterns.
Waldén, Markus; Krosshaug, Tron; Bjørneboe, John; Andersen, Thor Einar; Faul, Oliver
2015-01-01
Background Current knowledge on anterior cruciate ligament (ACL) injury mechanisms in male football players is limited. Aim To describe ACL injury mechanisms in male professional football players using systematic video analysis. Methods We assessed videos from 39 complete ACL tears recorded via prospective professional football injury surveillance between 2001 and 2011. Five analysts independently reviewed all videos to estimate the time of initial foot contact with the ground and the time of ACL tear. We then analysed all videos according to a structured format describing the injury circumstances and lower limb joint biomechanics. Results Twenty-five injuries were non-contact, eight indirect contact and six direct contact injuries. We identified three main categories of non-contact and indirect contact injury situations: (1) pressing (n=11), (2) re-gaining balance after kicking (n=5) and (3) landing after heading (n=5). The fourth main injury situation was direct contact with the injured leg or knee (n=6). Knee valgus was frequently seen in the main categories of non-contact and indirect contact playing situations (n=11), but a dynamic valgus collapse was infrequent (n=3). This was in contrast to the tackling-induced direct contact situations where a knee valgus collapse occurred in all cases (n=3). Conclusions Eighty-five per cent of the ACL injuries in male professional football players resulted from non-contact or indirect contact mechanisms. The most common playing situation leading to injury was pressing followed by kicking and heading. Knee valgus was frequently seen regardless of the playing situation, but a dynamic valgus collapse was rare. PMID:25907183
Lam, Wing-Kai; Ryue, Jaejin; Lee, Ki-Kwang; Park, Sang-Kyoon; Cheung, Jason Tak-Man; Ryu, Jiseon
2017-01-01
Lunge is one frequently executed movement in badminton and involves a unique sagittal footstrike angle of more than 40 degrees at initial ground contact compared with other manoeuvres. This study examined if the shoe heel curvature design of a badminton shoe would influence shoe-ground kinematics, ground reaction forces, and knee moments during lunge. Eleven elite and fifteen intermediate players performed five left-forward maximum lunge trials with Rounded Heel Shoe (RHS), Flattened Heel Shoe (FHS), and Standard Heel Shoes (SHS). Shoe-ground kinematics, ground reaction forces, and knee moments were measured by using synchronized force platform and motion analysis system. A 2 (Group) x 3 (Shoe) ANOVA with repeated measures was performed to determine the effects of different shoes and different playing levels, as well as the interaction of two factors on all variables. Shoe effect indicated that players demonstrated lower maximum vertical loading rate in RHS than the other two shoes (P < 0.05). Group effect revealed that elite players exhibited larger footstrike angle, faster approaching speed, lower peak horizontal force and horizontal loading rates but higher vertical loading rates and larger peak knee flexion and extension moments (P < 0.05). Analysis of Interactions of Group x Shoe for maximum and mean vertical loading rates (P < 0.05) indicated that elite players exhibited lower left maximum and mean vertical loading rates in RHS compared to FHS (P < 0.01), while the intermediate group did not show any Shoe effect on vertical loading rates. These findings indicate that shoe heel curvature would play some role in altering ground reaction force impact during badminton lunge. The differences in impact loads and knee moments between elite and intermediate players may be useful in optimizing footwear design and training strategy to minimize the potential risks for impact related injuries in badminton.
Wallis, Jason A; Webster, Kate E; Levinger, Pazit; Fong, Cynthia; Taylor, Nicholas F
2014-01-01
To determine if a pre-operative group rehabilitation programme can improve arthritis self-efficacy for people with severe hip and knee osteoarthritis. Single group, repeated measures design: 4-week baseline phase followed by a 6-week intervention phase of water exercise, and education with self-management strategies. The primary outcome was arthritis self-efficacy. The secondary outcomes were measures of pain (WOMAC), activity limitation (WOMAC), activity performance (30 s chair stand test, 10 m walk test) and health-related quality of life (EuroQol). Twenty participants (10 knee osteoarthritis and 10 hip osteoarthritis) with a mean age of 71 years (SD 7) attended 92% (SD 10%) of the scheduled sessions. All measures demonstrated baseline stability between two time points for measurements at week 1 and measurements at week 4. After the 6-week intervention programme there were no significant improvements for arthritis self-efficacy. There was a 12% increase for fast walking speed (mean increase of 0.14 m/s, 95% CI 0.07, 0.22). There were no significant improvements for other secondary outcomes. A pre-operative water-based exercise and educational programme did not improve arthritis self-efficacy, self-reported pain and activity limitation, and health-related quality of life for people with hip and knee osteoarthritis who were candidates for joint replacement. While there was a significant increase in one measure of activity performance (walking speed), these findings suggest the current programme may be of little value. Implications for Rehabilitation This pre-operative group rehabilitation programme for people with severe hip and knee osteoarthritis did not change arthritis self-efficacy, pain, activity limitation and health-related quality of life. This programme may have little value in preparing people for joint replacement surgery. The optimal pre-operative programme requires further design and investigation.
Impact of 10-weeks of yoga practice on flexibility and balance of college athletes
Polsgrove, M Jay; Eggleston, Brandon M; Lockyer, Roch J
2016-01-01
Background: With clearer evidence of its benefits, coaches, and athletes may better see that yoga has a role in optimizing performance. Aims: To determine the impact of yoga on male college athletes (N = 26). Methods: Over a 10-week period, a yoga group (YG) of athletes (n = 14) took part in biweekly yoga sessions; while a nonyoga group (NYG) of athletes (n = 12) took part in no additional yoga activity. Performance measures were obtained immediately before and after this period. Measurements of flexibility and balance, included: Sit-reach (SR), shoulder flexibility (SF), and stork stand (SS); dynamic measurements consisted of joint angles (JA) measured during the performance of three distinct yoga positions (downward dog [DD]; right foot lunge [RFL]; chair [C]). Results: Significant gains were observed in the YG for flexibility (SR, P = 0.01; SF, P = 0.03), and balance (SS, P = 0.05). No significant differences were observed in the NYG for flexibility and balance. Significantly, greater JA were observed in the YG for: RFL (dorsiflexion, l-ankle; P = 0.04), DD (extension, r-knee, P = 0.04; r-hip; P = 0.01; flexion, r-shoulder; P = 0.01) and C (flexion, r-knee; P = 0.01). Significant JA differences were observed in the NYG for: DD (flexion, r-knee, P = 0.01: r-hip, P = 0.05; r-shoulder, P = 0.03) and C (flexion r-knee, P = 0.01; extension, r-shoulder; P = 0.05). A between group comparison revealed the significant differences for: RFL (l-ankle; P = 0.01), DD (r-knee, P = 0.01; r-hip; P = 0.01), and C (r-shoulder, P = 0.02). Conclusions: Results suggest that a regular yoga practice may increase the flexibility and balance as well as whole body measures of male college athletes and therefore, may enhance athletic performances that require these characteristics. PMID:26865768
McCormick, Zachary L; Korn, Marc; Reddy, Rajiv; Marcolina, Austin; Dayanim, David; Mattie, Ryan; Cushman, Daniel; Bhave, Meghan; McCarthy, Robert J; Khan, Dost; Nagpal, Geeta; Walega, David R
2017-09-01
Determine outcomes of cooled radiofrequency ablation (C-RFA) of the genicular nerves for treatment of chronic knee pain due to osteoarthritis (OA). Cross-sectional survey. Academic pain medicine center. Consecutive patients with knee OA and 50% or greater pain relief following genicular nerve blocks who underwent genicular nerve C-RFA. Survey administration six or more months after C-RFA. Pain numeric rating scale (NRS), Medication Quantification Scale III (MQSIII), Patient Global Impression of Change (PGIC), and total knee arthroplasty (TKA) data were collected. Logistic regression was used to identify factors that predicted treatment success. Thirty-three patients (52 discrete knees) met inclusion criteria. Thirty-five percent (95% confidence interval [CI] = 22-48) of procedures resulted in the combined outcome of 50% or greater reduction in NRS score, reduction of 3.4 or more points in MQSIII score, and PGIC score consistent with "very much improved/improved." Nineteen percent (95% CI = 10-33) of procedures resulted in complete pain relief. Greater duration of pain and greater than 80% pain relief from diagnostic blocks were identified as predictors of treatment success. The accuracy of the model was 0.88 (95% CI = 0.78-0.97, P < 0.001). Genicular C-RFA demonstrated a success rate of 35% based on a robust combination of outcome measures, and 19% of procedures resulted in complete relief of pain at a minimum of six months of follow-up. Report of 80% or greater relief from diagnostic blocks and duration of pain of less than five years are associated with high accuracy in predicting treatment success. Further prospective study is needed to optimize the patient selection protocol and success rate of this procedure. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Cheung, Jason Tak-Man; Ryu, Jiseon
2017-01-01
Background Lunge is one frequently executed movement in badminton and involves a unique sagittal footstrike angle of more than 40 degrees at initial ground contact compared with other manoeuvres. This study examined if the shoe heel curvature design of a badminton shoe would influence shoe-ground kinematics, ground reaction forces, and knee moments during lunge. Methods Eleven elite and fifteen intermediate players performed five left-forward maximum lunge trials with Rounded Heel Shoe (RHS), Flattened Heel Shoe (FHS), and Standard Heel Shoes (SHS). Shoe-ground kinematics, ground reaction forces, and knee moments were measured by using synchronized force platform and motion analysis system. A 2 (Group) x 3 (Shoe) ANOVA with repeated measures was performed to determine the effects of different shoes and different playing levels, as well as the interaction of two factors on all variables. Results Shoe effect indicated that players demonstrated lower maximum vertical loading rate in RHS than the other two shoes (P < 0.05). Group effect revealed that elite players exhibited larger footstrike angle, faster approaching speed, lower peak horizontal force and horizontal loading rates but higher vertical loading rates and larger peak knee flexion and extension moments (P < 0.05). Analysis of Interactions of Group x Shoe for maximum and mean vertical loading rates (P < 0.05) indicated that elite players exhibited lower left maximum and mean vertical loading rates in RHS compared to FHS (P < 0.01), while the intermediate group did not show any Shoe effect on vertical loading rates. Conclusions These findings indicate that shoe heel curvature would play some role in altering ground reaction force impact during badminton lunge. The differences in impact loads and knee moments between elite and intermediate players may be useful in optimizing footwear design and training strategy to minimize the potential risks for impact related injuries in badminton. PMID:28334016
Structural damage detection-oriented multi-type sensor placement with multi-objective optimization
NASA Astrophysics Data System (ADS)
Lin, Jian-Fu; Xu, You-Lin; Law, Siu-Seong
2018-05-01
A structural damage detection-oriented multi-type sensor placement method with multi-objective optimization is developed in this study. The multi-type response covariance sensitivity-based damage detection method is first introduced. Two objective functions for optimal sensor placement are then introduced in terms of the response covariance sensitivity and the response independence. The multi-objective optimization problem is formed by using the two objective functions, and the non-dominated sorting genetic algorithm (NSGA)-II is adopted to find the solution for the optimal multi-type sensor placement to achieve the best structural damage detection. The proposed method is finally applied to a nine-bay three-dimensional frame structure. Numerical results show that the optimal multi-type sensor placement determined by the proposed method can avoid redundant sensors and provide satisfactory results for structural damage detection. The restriction on the number of each type of sensors in the optimization can reduce the searching space in the optimization to make the proposed method more effective. Moreover, how to select a most optimal sensor placement from the Pareto solutions via the utility function and the knee point method is demonstrated in the case study.
Marker-free motion correction in weight-bearing cone-beam CT of the knee joint.
Berger, M; Müller, K; Aichert, A; Unberath, M; Thies, J; Choi, J-H; Fahrig, R; Maier, A
2016-03-01
To allow for a purely image-based motion estimation and compensation in weight-bearing cone-beam computed tomography of the knee joint. Weight-bearing imaging of the knee joint in a standing position poses additional requirements for the image reconstruction algorithm. In contrast to supine scans, patient motion needs to be estimated and compensated. The authors propose a method that is based on 2D/3D registration of left and right femur and tibia segmented from a prior, motion-free reconstruction acquired in supine position. Each segmented bone is first roughly aligned to the motion-corrupted reconstruction of a scan in standing or squatting position. Subsequently, a rigid 2D/3D registration is performed for each bone to each of K projection images, estimating 6 × 4 × K motion parameters. The motion of individual bones is combined into global motion fields using thin-plate-spline extrapolation. These can be incorporated into a motion-compensated reconstruction in the backprojection step. The authors performed visual and quantitative comparisons between a state-of-the-art marker-based (MB) method and two variants of the proposed method using gradient correlation (GC) and normalized gradient information (NGI) as similarity measure for the 2D/3D registration. The authors evaluated their method on four acquisitions under different squatting positions of the same patient. All methods showed substantial improvement in image quality compared to the uncorrected reconstructions. Compared to NGI and MB, the GC method showed increased streaking artifacts due to misregistrations in lateral projection images. NGI and MB showed comparable image quality at the bone regions. Because the markers are attached to the skin, the MB method performed better at the surface of the legs where the authors observed slight streaking of the NGI and GC methods. For a quantitative evaluation, the authors computed the universal quality index (UQI) for all bone regions with respect to the motion-free reconstruction. The authors quantitative evaluation over regions around the bones yielded a mean UQI of 18.4 for no correction, 53.3 and 56.1 for the proposed method using GC and NGI, respectively, and 53.7 for the MB reference approach. In contrast to the authors registration-based corrections, the MB reference method caused slight nonrigid deformations at bone outlines when compared to a motion-free reference scan. The authors showed that their method based on the NGI similarity measure yields reconstruction quality close to the MB reference method. In contrast to the MB method, the proposed method does not require any preparation prior to the examination which will improve the clinical workflow and patient comfort. Further, the authors found that the MB method causes small, nonrigid deformations at the bone outline which indicates that markers may not accurately reflect the internal motion close to the knee joint. Therefore, the authors believe that the proposed method is a promising alternative to MB motion management.
Marker-free motion correction in weight-bearing cone-beam CT of the knee joint
Berger, M.; Müller, K.; Aichert, A.; Unberath, M.; Thies, J.; Choi, J.-H.; Fahrig, R.; Maier, A.
2016-01-01
Purpose: To allow for a purely image-based motion estimation and compensation in weight-bearing cone-beam computed tomography of the knee joint. Methods: Weight-bearing imaging of the knee joint in a standing position poses additional requirements for the image reconstruction algorithm. In contrast to supine scans, patient motion needs to be estimated and compensated. The authors propose a method that is based on 2D/3D registration of left and right femur and tibia segmented from a prior, motion-free reconstruction acquired in supine position. Each segmented bone is first roughly aligned to the motion-corrupted reconstruction of a scan in standing or squatting position. Subsequently, a rigid 2D/3D registration is performed for each bone to each of K projection images, estimating 6 × 4 × K motion parameters. The motion of individual bones is combined into global motion fields using thin-plate-spline extrapolation. These can be incorporated into a motion-compensated reconstruction in the backprojection step. The authors performed visual and quantitative comparisons between a state-of-the-art marker-based (MB) method and two variants of the proposed method using gradient correlation (GC) and normalized gradient information (NGI) as similarity measure for the 2D/3D registration. Results: The authors evaluated their method on four acquisitions under different squatting positions of the same patient. All methods showed substantial improvement in image quality compared to the uncorrected reconstructions. Compared to NGI and MB, the GC method showed increased streaking artifacts due to misregistrations in lateral projection images. NGI and MB showed comparable image quality at the bone regions. Because the markers are attached to the skin, the MB method performed better at the surface of the legs where the authors observed slight streaking of the NGI and GC methods. For a quantitative evaluation, the authors computed the universal quality index (UQI) for all bone regions with respect to the motion-free reconstruction. The authors quantitative evaluation over regions around the bones yielded a mean UQI of 18.4 for no correction, 53.3 and 56.1 for the proposed method using GC and NGI, respectively, and 53.7 for the MB reference approach. In contrast to the authors registration-based corrections, the MB reference method caused slight nonrigid deformations at bone outlines when compared to a motion-free reference scan. Conclusions: The authors showed that their method based on the NGI similarity measure yields reconstruction quality close to the MB reference method. In contrast to the MB method, the proposed method does not require any preparation prior to the examination which will improve the clinical workflow and patient comfort. Further, the authors found that the MB method causes small, nonrigid deformations at the bone outline which indicates that markers may not accurately reflect the internal motion close to the knee joint. Therefore, the authors believe that the proposed method is a promising alternative to MB motion management. PMID:26936708
Erhart-Hledik, Jennifer C; Kinsella, Rose; Hunter, Simon; Mecklenburg, Gabriel; Perez, Daniel
2017-01-01
Background Chronic knee pain (CKP) affects a large number of adults, many of whom do not receive best-practice care and are at high risk for unnecessary surgery. Objective The aim of this study was to investigate the effect of the Hinge Health 12-week digital care program (DCP) for CKP on knee pain and function, with secondary outcomes of surgery interest and satisfaction, at 12 weeks and 6 months after starting the program. Methods Individuals with CKP were recruited onto the 12-week program, comprising sensor-guided physical exercises, weekly education, activity tracking, and psychosocial support such as personal coaching and cognitive behavioral therapy (CBT). We used a single-arm design with assessment of outcomes at baseline, 12 weeks, and 6 months after starting the program. We used a linear mixed effects model with Tukey contrasts to compare timepoints and report intention-to-treat statistics with last observation carried forward. Results The cohort consisted of 41 individuals (32 female, mean age 52 years, SD 9 years). Between baseline and week 12, participants reported clinically significant improvements in the Knee Injury and Osteoarthritis Outcome Score (KOOS) pain and Knee Injury and Osteoarthritis Outcome Score-Physical Function Short Form (KOOS-PS) function scales of 16 points (95% CI 12-21, P<.001) and 10 points (95% CI 6-14, P<.001), respectively. Significant reductions of 57% (mean difference 30, 95% CI 21-38, P<.001) and 51% (mean difference 25, 95% CI 16-33, P<.001) in visual analog scale (VAS) knee pain and stiffness, respectively, were observed at 12 weeks, as well as a 67% reduction in surgery interest (mean reduction 2.3 out of 10, 95% CI 1.5-3.1, P<.001). Average satisfaction at week 12 was 9.2 out of 10. Critically, all improvements were maintained at 6 months at similar or greater magnitude. Conclusions Participants on the Hinge Health DCP for CKP showed substantial clinical improvements that were maintained 6 months after enrolling in the program. This shows that DCPs carry strong potential to deliver evidence-based, cost-effective care to those suffering from CKP. PMID:28582253
Tigchelaar, S; van Sambeeck, J; Koeter, S; van Kampen, A
2018-04-01
Trochlear osteotomy is a rarely performed procedure, only indicated in selected cases. Due to its nature, it can potentially lead to cartilage damage and subsequent early osteoarthritis. Satisfactory short-term results from lateral condyle-elevating osteotomy have previously been reported. The long-term effects of this procedure on clinical outcomes, patellar stability and radiological osteoarthritis are reported here. Sixteen patients (19 knees) with patellar instability due to trochlear dysplasia were included. An isolated lateral condyle-elevating trochlear osteotomy was performed between 1995 and 2002. All patients were re-examined at a minimum of 12-year follow-up. Three patients were lost to follow-up, and one patient underwent a patellofemoral arthroplasty 3 years post-operatively due to progressive osteoarthritis. Complete follow-up was therefore available in 12 patients (15 knees). Recurrent instability, VAS pain, WOMAC, Lysholm and Kujala scores were used as outcome measures. Radiological osteoarthritis was recorded using the Iwano and the Kellgren-Lawrence classifications. A repeated-measures ANOVA was used to test for repeated measures (pre-operative, 2-year and final follow-up), and Spearman's correlation coefficient for relationships between osteoarthritis and functional scores. At final follow-up, VAS pain showed a non-significant improvement from 52 to 25, and the median Kujala score was 78. Median Lysholm (54-71, p = 0.021) and WOMAC (78-96, p = 0.021) scores improved from the pre-operative assessment to final follow-up. There was no significant difference observed between clinical scores at the 2-year and final follow-up. Residual patellar instability was reported in four out of 15 knees. Three knees showed no patellofemoral osteoarthritis, eight knees had grade 1 and four knees grade 2. No correlation between VAS pain, Lysholm, WOMAC or Kujala scores and osteoarthritis could be identified (n.s.). A stand-alone lateral condyle-elevating trochleoplasty results in the significant improvement of most clinical scores; however, when performed as a stand-alone procedure, it leads to a high percentage of residual instability. In contrast to general belief, the development of patellofemoral osteoarthritis at 12-year follow-up did not exceed the findings from other trochleoplasty case series. Case series with no comparison group, Level IV.
Cationic Contrast Agent Diffusion Differs Between Cartilage and Meniscus.
Honkanen, Juuso T J; Turunen, Mikael J; Freedman, Jonathan D; Saarakkala, Simo; Grinstaff, Mark W; Ylärinne, Janne H; Jurvelin, Jukka S; Töyräs, Juha
2016-10-01
Contrast enhanced computed tomography (CECT) is a non-destructive imaging technique used for the assessment of composition and structure of articular cartilage and meniscus. Due to structural and compositional differences between these tissues, diffusion and distribution of contrast agents may differ in cartilage and meniscus. The aim of this study is to determine the diffusion kinematics of a novel iodine based cationic contrast agent (CA(2+)) in cartilage and meniscus. Cylindrical cartilage and meniscus samples (d = 6 mm, h ≈ 2 mm) were harvested from healthy bovine knee joints (n = 10), immersed in isotonic cationic contrast agent (20 mgI/mL), and imaged using a micro-CT scanner at 26 time points up to 48 h. Subsequently, normalized X-ray attenuation and contrast agent diffusion flux, as well as water, collagen and proteoglycan (PG) contents in the tissues were determined. The contrast agent distributions within cartilage and meniscus were different. In addition, the normalized attenuation and diffusion flux were higher (p < 0.05) in cartilage. Based on these results, diffusion kinematics vary between cartilage and meniscus. These tissue specific variations can affect the interpretation of CECT images and should be considered when cartilage and meniscus are assessed simultaneously.
Ménigot, Sébastien; Girault, Jean-Marc
2013-01-01
Ultrasound contrast imaging has provided more accurate medical diagnoses thanks to the development of innovating modalities like the pulse inversion imaging. However, this latter modality that improves the contrast-to-tissue ratio (CTR) is not optimal, since the frequency is manually chosen jointly with the probe. However, an optimal choice of this command is possible, but it requires precise information about the transducer and the medium which can be experimentally difficult to obtain, even inaccessible. It turns out that the optimization can become more complex by taking into account the kind of generators, since the generators of electrical signals in a conventional ultrasound scanner can be unipolar, bipolar, or tripolar. Our aim was to seek the ternary command which maximized the CTR. By combining a genetic algorithm and a closed loop, the system automatically proposed the optimal ternary command. In simulation, the gain compared with the usual ternary signal could reach about 3.9 dB. Another interesting finding was that, in contrast to what is generally accepted, the optimal command was not a fixed-frequency signal but had harmonic components.
Improved specimen reconstruction by Hilbert phase contrast tomography.
Barton, Bastian; Joos, Friederike; Schröder, Rasmus R
2008-11-01
The low signal-to-noise ratio (SNR) in images of unstained specimens recorded with conventional defocus phase contrast makes it difficult to interpret 3D volumes obtained by electron tomography (ET). The high defocus applied for conventional tilt series generates some phase contrast but leads to an incomplete transfer of object information. For tomography of biological weak-phase objects, optimal image contrast and subsequently an optimized SNR are essential for the reconstruction of details such as macromolecular assemblies at molecular resolution. The problem of low contrast can be partially solved by applying a Hilbert phase plate positioned in the back focal plane (BFP) of the objective lens while recording images in Gaussian focus. Images recorded with the Hilbert phase plate provide optimized positive phase contrast at low spatial frequencies, and the contrast transfer in principle extends to the information limit of the microscope. The antisymmetric Hilbert phase contrast (HPC) can be numerically converted into isotropic contrast, which is equivalent to the contrast obtained by a Zernike phase plate. Thus, in-focus HPC provides optimal structure factor information without limiting effects of the transfer function. In this article, we present the first electron tomograms of biological specimens reconstructed from Hilbert phase plate image series. We outline the technical implementation of the phase plate and demonstrate that the technique is routinely applicable for tomography. A comparison between conventional defocus tomograms and in-focus HPC volumes shows an enhanced SNR and an improved specimen visibility for in-focus Hilbert tomography.
Image quality, threshold contrast and mean glandular dose in CR mammography
NASA Astrophysics Data System (ADS)
Jakubiak, R. R.; Gamba, H. R.; Neves, E. B.; Peixoto, J. E.
2013-09-01
In many countries, computed radiography (CR) systems represent the majority of equipment used in digital mammography. This study presents a method for optimizing image quality and dose in CR mammography of patients with breast thicknesses between 45 and 75 mm. Initially, clinical images of 67 patients (group 1) were analyzed by three experienced radiologists, reporting about anatomical structures, noise and contrast in low and high pixel value areas, and image sharpness and contrast. Exposure parameters (kV, mAs and target/filter combination) used in the examinations of these patients were reproduced to determine the contrast-to-noise ratio (CNR) and mean glandular dose (MGD). The parameters were also used to radiograph a CDMAM (version 3.4) phantom (Artinis Medical Systems, The Netherlands) for image threshold contrast evaluation. After that, different breast thicknesses were simulated with polymethylmethacrylate layers and various sets of exposure parameters were used in order to determine optimal radiographic parameters. For each simulated breast thickness, optimal beam quality was defined as giving a target CNR to reach the threshold contrast of CDMAM images for acceptable MGD. These results were used for adjustments in the automatic exposure control (AEC) by the maintenance team. Using optimized exposure parameters, clinical images of 63 patients (group 2) were evaluated as described above. Threshold contrast, CNR and MGD for such exposure parameters were also determined. Results showed that the proposed optimization method was effective for all breast thicknesses studied in phantoms. The best result was found for breasts of 75 mm. While in group 1 there was no detection of the 0.1 mm critical diameter detail with threshold contrast below 23%, after the optimization, detection occurred in 47.6% of the images. There was also an average MGD reduction of 7.5%. The clinical image quality criteria were attended in 91.7% for all breast thicknesses evaluated in both patient groups. Finally, this study also concluded that the use of the AEC of the x-ray unit based on the constant dose to the detector may bring some difficulties to CR systems to operate under optimal conditions. More studies must be performed, so that the compatibility between systems and optimization methodologies can be evaluated, as well as this optimization method. Most methods are developed for phantoms, so comparative studies including clinical images must be developed.
The Effects of Walking Speed on Tibiofemoral Loading Estimated Via Musculoskeletal Modeling
Lerner, Zachary F.; Haight, Derek J.; DeMers, Matthew S.; Board, Wayne J.; Browning, Raymond C.
2015-01-01
Net muscle moments (NMMs) have been used as proxy measures of joint loading, but musculoskeletal models can estimate contact forces within joints. The purpose of this study was to use a musculoskeletal model to estimate tibiofemoral forces and to examine the relationship between NMMs and tibiofemoral forces across walking speeds. We collected kinematic, kinetic, and electromyographic data as ten adult participants walked on a dual-belt force-measuring treadmill at 0.75, 1.25, and 1.50 m/s. We scaled a musculoskeletal model to each participant and used OpenSim to calculate the NMMs and muscle forces through inverse dynamics and weighted static optimization, respectively. We determined tibiofemoral forces from the vector sum of intersegmental and muscle forces crossing the knee. Estimated tibiofemoral forces increased with walking speed. Peak early-stance compressive tibiofemoral forces increased 52% as walking speed increased from 0.75 to 1.50 m/s, whereas peak knee extension NMMs increased by 168%. During late stance, peak compressive tibiofemoral forces increased by 18% as speed increased. Although compressive loads at the knee did not increase in direct proportion to NMMs, faster walking resulted in greater compressive forces during weight acceptance and increased compressive and anterior/posterior tibiofemoral loading rates in addition to a greater abduction NMM. PMID:23878264
The Impact of Personality Traits on the Outcome of Total Knee Arthroplasty.
Giurea, A; Fraberger, G; Kolbitsch, P; Lass, R; Schneider, E; Kubista, B; Windhager, R
2016-01-01
Ten to twenty percent of patients with total knee arthroplasty (TKA) are dissatisfied with their clinical outcome. Aim of this study was to investigate the impact of personality traits on the subjective outcome of TKA. We investigated 80 patients with 86 computer navigated TKAs. We asked for patients satisfaction and divided patients into two groups (satisfied or dissatisfied). 12 personality traits were tested by the Freiburg Personality Inventory (FPI-R). Postoperative examination included Knee Society Score (KSS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC), and the Visual Analogue Scale (VAS). Radiologic investigation was done in all patients. 84% of our patients were satisfied, while 16% were not satisfied. The FPI-R showed statistical significant influence of four personality traits on patient satisfaction: life satisfaction (p = 0.006), performance orientation (p = 0.015), somatic distress (p = 0.001), and emotional stability (p = 0.002). All clinical scores (VAS, WOMAC, and KSS) showed significantly better results in the satisfied patient. Radiological examination showed optimal alignment of all TKAs. There were no complications requiring revision surgery. The results of our study show that personality traits may influence patients satisfaction and clinical outcome after TKA. Therefore patients personality traits may be a useful predictive factor for postoperative satisfaction after TKA.
The Impact of Personality Traits on the Outcome of Total Knee Arthroplasty
Giurea, A.; Fraberger, G.; Kolbitsch, P.; Lass, R.; Schneider, E.; Kubista, B.; Windhager, R.
2016-01-01
Ten to twenty percent of patients with total knee arthroplasty (TKA) are dissatisfied with their clinical outcome. Aim of this study was to investigate the impact of personality traits on the subjective outcome of TKA. We investigated 80 patients with 86 computer navigated TKAs. We asked for patients satisfaction and divided patients into two groups (satisfied or dissatisfied). 12 personality traits were tested by the Freiburg Personality Inventory (FPI-R). Postoperative examination included Knee Society Score (KSS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC), and the Visual Analogue Scale (VAS). Radiologic investigation was done in all patients. 84% of our patients were satisfied, while 16% were not satisfied. The FPI-R showed statistical significant influence of four personality traits on patient satisfaction: life satisfaction (p = 0.006), performance orientation (p = 0.015), somatic distress (p = 0.001), and emotional stability (p = 0.002). All clinical scores (VAS, WOMAC, and KSS) showed significantly better results in the satisfied patient. Radiological examination showed optimal alignment of all TKAs. There were no complications requiring revision surgery. The results of our study show that personality traits may influence patients satisfaction and clinical outcome after TKA. Therefore patients personality traits may be a useful predictive factor for postoperative satisfaction after TKA. PMID:26989686
The floating knee: a review on ipsilateral femoral and tibial fractures
Muñoz Vives, Josep; Bel, Jean-Christophe; Capel Agundez, Arantxa; Chana Rodríguez, Francisco; Palomo Traver, José; Schultz-Larsen, Morten; Tosounidis, Theodoros
2016-01-01
In 1975, Blake and McBryde established the concept of ‘floating knee’ to describe ipsilateral fractures of the femur and tibia.1 This combination is much more than a bone lesion; the mechanism is usually a high-energy trauma in a patient with multiple injuries and a myriad of other lesions. After initial evaluation patients should be categorised, and only stable patients should undergo immediate reduction and internal fixation with the rest receiving external fixation. Definitive internal fixation of both bones yields the best results in almost all series. Nailing of both bones is the optimal fixation when both fractures (femoral and tibial) are extra-articular. Plates are the ‘standard of care’ in cases with articular fractures. A combination of implants are required by 40% of floating knees. Associated ligamentous and meniscal lesions are common, but may be irrelevant in the case of an intra-articular fracture which gives the worst prognosis for this type of lesion. Cite this article: Muñoz Vives K, Bel J-C, Capel Agundez A, Chana Rodríguez F, Palomo Traver J, Schultz-Larsen M, Tosounidis, T. The floating knee. EFORT Open Rev 2016;1:375-382. DOI: 10.1302/2058-5241.1.000042. PMID:28461916
NASA Astrophysics Data System (ADS)
Jiang, G.; Wong, C. Y.; Lin, S. C. F.; Rahman, M. A.; Ren, T. R.; Kwok, Ngaiming; Shi, Haiyan; Yu, Ying-Hao; Wu, Tonghai
2015-04-01
The enhancement of image contrast and preservation of image brightness are two important but conflicting objectives in image restoration. Previous attempts based on linear histogram equalization had achieved contrast enhancement, but exact preservation of brightness was not accomplished. A new perspective is taken here to provide balanced performance of contrast enhancement and brightness preservation simultaneously by casting the quest of such solution to an optimization problem. Specifically, the non-linear gamma correction method is adopted to enhance the contrast, while a weighted sum approach is employed for brightness preservation. In addition, the efficient golden search algorithm is exploited to determine the required optimal parameters to produce the enhanced images. Experiments are conducted on natural colour images captured under various indoor, outdoor and illumination conditions. Results have shown that the proposed method outperforms currently available methods in contrast to enhancement and brightness preservation.
Chahla, Jorge; Piuzzi, Nicolas S; Mitchell, Justin J; Dean, Chase S; Pascual-Garrido, Cecilia; LaPrade, Robert F; Muschler, George F
2016-09-21
Intra-articular cellular therapy injections constitute an appealing strategy that may modify the intra-articular milieu or regenerate cartilage in the settings of osteoarthritis and focal cartilage defects. However, little consensus exists regarding the indications for cellular therapies, optimal cell sources, methods of preparation and delivery, or means by which outcomes should be reported. We present a systematic review of the current literature regarding the safety and efficacy of cellular therapy delivered by intra-articular injection in the knee that provided a Level of Evidence of III or higher. A total of 420 papers were screened. Methodological quality was assessed using a modified Coleman methodology score. Only 6 studies (4 Level II and 2 Level III) met the criteria to be included in this review; 3 studies were on treatment of osteoarthritis and 3 were on treatment of focal cartilage defects. These included 4 randomized controlled studies without blinding, 1 prospective cohort study, and 1 retrospective therapeutic case-control study. The studies varied widely with respect to cell sources, cell characterization, adjuvant therapies, and assessment of outcomes. Outcome was reported in a total of 300 knees (124 in the osteoarthritis studies and 176 in the cartilage defect studies). Mean follow-up was 21.0 months (range, 12 to 36 months). All studies reported improved outcomes with intra-articular cellular therapy and no major adverse events. The mean modified Coleman methodology score was 59.1 ± 16 (range, 32 to 82). The studies of intra-articular cellular therapy injections for osteoarthritis and focal cartilage defects in the human knee suggested positive results with respect to clinical improvement and safety. However, the improvement was modest and a placebo effect cannot be disregarded. The overall quality of the literature was poor, and the methodological quality was fair, even among Level-II and III studies. Effective clinical assessment and optimization of injection therapies will demand greater attention to study methodology, including blinding; standardized quantitative methods for cell harvesting, processing, characterization, and delivery; and standardized reporting of clinical and structural outcomes. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.
Optimization of contrast resolution by genetic algorithm in ultrasound tissue harmonic imaging.
Ménigot, Sébastien; Girault, Jean-Marc
2016-09-01
The development of ultrasound imaging techniques such as pulse inversion has improved tissue harmonic imaging. Nevertheless, no recommendation has been made to date for the design of the waveform transmitted through the medium being explored. Our aim was therefore to find automatically the optimal "imaging" wave which maximized the contrast resolution without a priori information. To overcome assumption regarding the waveform, a genetic algorithm investigated the medium thanks to the transmission of stochastic "explorer" waves. Moreover, these stochastic signals could be constrained by the type of generator available (bipolar or arbitrary). To implement it, we changed the current pulse inversion imaging system by including feedback. Thus the method optimized the contrast resolution by adaptively selecting the samples of the excitation. In simulation, we benchmarked the contrast effectiveness of the best found transmitted stochastic commands and the usual fixed-frequency command. The optimization method converged quickly after around 300 iterations in the same optimal area. These results were confirmed experimentally. In the experimental case, the contrast resolution measured on a radiofrequency line could be improved by 6% with a bipolar generator and it could still increase by 15% with an arbitrary waveform generator. Copyright © 2016 Elsevier B.V. All rights reserved.
Lower-extremity biomechanics during forward and lateral stepping activities in older adults
Wang, Man-Ying; Flanagan, Sean; Song, Joo-Eun; Greendale, Gail A.; Salem, George J.
2012-01-01
Objective To characterize the lower-extremity biomechanics associated with stepping activities in older adults. Design Repeated-measures comparison of kinematics and kinetics associated with forward step-up and lateral step-up activities. Background Biomechanical analysis may be used to assess the effectiveness of various ‘in-home activities’ in targeting appropriate muscle groups and preserving functional strength and power in elders. Methods Data were analyzed from 21 participants (mean 74.7 yr (standard deviation, 4.4 yr)) who performed the forward and lateral step-up activities while instrumented for biomechanical analysis. Motion analysis equipment, inverse dynamics equations, and repeated measures anovas were used to contrast the maximum joint angles, peak net joint moments, angular impulse, work, and power associated with the activities. Results The lateral step-up resulted in greater maximum knee flexion (P < 0.001) and ankle dorsiflexion angles (P < 0.01). Peak joint moments were similar between exercises. The forward step-up generated greater peak hip power (P < 0.05) and total work (P < 0.001); whereas, the lateral step-up generated greater impulse (P < 0.05), work (P < 0.01), and power (P < 0.05) at the knee and ankle. Conclusions In older adults, the forward step-up places greater demand on the hip extensors, while lateral step-up places greater demand on the knee extensors and ankle plantar flexors. PMID:12620784
Functional assessment of a surgical robot for reduction of lower limb fractures.
Hung, Shuo-Suei; Lee, Ming-Yih
2010-12-01
This paper presents a novel robot designed for reduction of lower limb fractures, with the additional features of automatic controlled flexion of the knee joint, individual traction of thigh and leg, and foot rotation. The aim of this design is to assist the orthopaedic surgeon to perform better fracture reduction through motor control, in contrast to current manual control, and the results of assessments of its functions on normal subjects are presented in this paper. The robot was designed to be mounted onto the operation table, and was controlled through open switch relay. Functional assessments were conducted on six healthy volunteers in terms of knee joint motion and lower limb traction; measurement of angle and distance was calculated from data obtained by a 3D ultrasonic motion system (Zebris(®) ). The results showed a good correlation of the flexion angle between the robot and the subjects at the knee joint. In the traction tests, a steady lengthening of the proximal as well as the distal segment of the robot was observed, and a slight increase in subjects' limb length was also recorded, which might be due to distraction in the joint space. This automatic control fracture table has distinct features compared with the conventional ones, and it is believed to be of assistance to surgeons when performing fracture fixations. Copyright © 2010 John Wiley & Sons, Ltd.
Bell, M A; Fox, N A
1997-12-01
This work was designed to investigate individual differences in hands-and-knees crawling and frontal brain electrical activity with respect to object permanence performance in 76 eight-month-old infants. Four groups of infants (one prelocomotor and 3 with varying lengths of hands-and-knees crawling experience) were tested on an object permanence scale in a research design similar to that used by Kermoian and Campos (1988). In addition, baseline EEG was recorded and used as an indicator of brain development, as in the Bell and Fox (1992) longitudinal study. Individual differences in frontal and occipital EEG power and in locomotor experience were associated with performance on the object permanence task. Infants successful at A-not-B exhibited greater frontal EEG power and greater occipital EEG power than unsuccessful infants. In contrast to Kermoian and Campos (1988), who noted that long-term crawling experience was associated with higher performance on an object permanence scale, infants in this study with any amount of hands and knees crawling experience performed at a higher level on the object permanence scale than prelocomotor infants. There was no interaction among brain electrical activity, locomotor experience, and object permanence performance. These data highlight the value of electrophysiological research and the need for a brain-behavior model of object permanence performance that incorporates both electrophysiological and behavioral factors.
Williams, J M; Brandt, K D
1985-11-01
Although corticosteroids have been shown to cause articular cartilage degeneration, recent studies of experimentally induced osteoarthritis indicate that under certain conditions they may protect against cartilage damage and osteophyte formation. The present study examines the in vivo effect of triamcinolone hexacetonide on the degeneration of articular cartilage which occurs following intraarticular injection of sodium iodoacetate. Three weeks after a single injection of iodoacetate into the knees of guinea pigs, ipsilateral femoral condylar cartilage exhibited fibrillation, loss of staining with Safranin O, depletion of chondrocytes, and prominent osteophytes. In striking contrast, when triamcinolone hexacetonide was injected into the ipsilateral knee 24 hours after the intraarticular injection of iodoacetate, fibrillation was noted in only 1 of 6 samples, osteophytes were much less prominent, pericellular staining with Safranin O persisted, and cell loss was less extensive. Knees of animals which received only one-tenth as much intraarticular triamcinolone hexacetonide after the iodoacetate injection also exhibited marked reduction in size and extent of osteophytes. However, the degree of fibrillation, loss of Safranin O staining, and chondrocyte depletion was similar to that observed in animals injected with iodoacetate but not treated with intraarticular steroid. No apparent morphologic or histochemical changes were observed after intraarticular injection of the steroid preparation alone. Thus, triamcinolone hexacetonide produced a marked, dose-dependent protective effect in this model of chemically induced articular cartilage damage.
Vincent, Heather K; Lamb, Kelley M; Day, Tim I; Tillman, Susan M; Vincent, Kevin R; George, Steven Z
2010-08-01
To compare fear of movement in patients with different body mass index (BMI) values referred for rehabilitative care of the knee and to examine whether this fear contributed to self-reported knee-related function. We hypothesized that fear of movement would be elevated with increasing BMI and that fear would correspond with lower self-report knee-related function and lower quality of life (QOL). Retrospective cross-sectional study. Outpatient therapy clinic affiliated with a tertiary care hospital. Patients with knee pain diagnoses (n = 278) were stratified into 4 BMI groups (in < or =25 kg/m(2) nonobese; 25-29.9 kg/m(2) overweight; 30-39.9 kg/m(2) obese; > or =40 kg/m(2) morbidly obese). The Tampa Scale of Kinesiophobia (TSK; fear of movement), International Knee Documentation (IKDC; knee function), and Short-Form 8 (SF-8; QOL) scores were main outcomes. Pain and straight leg raise test scores also were collected. After review of the medical records, descriptive statistics and nonparametric tests were performed, and TSK, QOL, and SF-8 scores were compared. Hierarchical regression modeling determined the contribution of TSK scores to the variance of IKDC scores. Pain scores were greatest in the nonobese group and lowest in the morbidly obese group (7.5 +/- 2.6 points vs 4.8 +/- 3.1 points; P < .05). TSK scores in morbidly obese patients were greater than in nonobese patients (27.1 +/- 7.7 points vs 22.0 +/- 6.6 points; P = .002). The SF-8 mental-physical subscores were 27% to 32% lower in the morbidly obese than nonobese patients (both P < .0001). IKDC scores were lower in the morbidly obese than nonobese patients (32.1 +/- 19.2 points vs 50.9 +/- 23.8 points; P = .0001). Pain severity and TSK scores contributed 28.6% and 7.1% to the variance of the IKDC scores (overall R(2) = 68.6). Morbid obesity is associated with elevated fear of movement. Pain was the strongest predictor of IKDC scores, and fear of movement enhanced this predictive value of the regression model. Despite lower absolute pain severity in the morbidly obese group, this fear may influence IKDC scores in this population. Morbidly obese patients might benefit from rehabilitation activities that reduce fear of movement to optimize participation in rehabilitation activity. Copyright © 2010 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Kim, Young-Hoo; Park, Jang-Won; Kim, Jun-Shik
2017-10-01
The purpose of this study was to compare the long-term clinical results, radiographic results, range of knee motion, patient satisfaction, and the survival rate of Medial-Pivot posterior cruciate-substituting, knee prosthesis and a press-fit condylar (PFC) Sigma cruciate-retaining mobile-bearing knee prosthesis in the same patients. One hundred eighty-two patients received Medial-Pivot knee prosthesis in one knee and a PFC Sigma knee prosthesis in the contralateral knee. The minimum duration of follow-up was 11 years (range, 11-12.6 years). The knees with a Medial-Pivot knee prosthesis had significantly worse results than those with a PFC Sigma knee prosthesis at the final follow-up with regard to the mean postoperative Knee Society knee scores (90 compared with 95 points), Western Ontario and McMaster Universities Osteoarthritis Index score (25 compared with 18 points), and range of knee motion (117° compared with 128°). Patients were more satisfied with PFC Sigma knee prosthesis (93%) than with Medial-Pivot knee prosthesis (75%). Complication rates were significantly higher in the Medial-Pivot knee group (26%) than those in the PFC Sigma knee group (6.5%). Radiographic results and survival rates (99% compared with 99.5%) were similar between the 2 groups. Although the long-term fixation and survival rate of both Medial-Pivot and PFC Sigma prostheses were similar, we observed a worse knee score, worse range of knee motion, and patient satisfaction was less in the Medial-Pivot knee group than in the PFC Sigma knee group. Furthermore, complication rate was also higher in the Medial-Pivot knee group than the other group. Copyright © 2017 Elsevier Inc. All rights reserved.
21 CFR 888.3570 - Knee joint femoral (hemi-knee) metallic uncemented prosthesis.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femoral (hemi-knee) metallic uncemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3570 Knee joint femoral (hemi-knee) metallic uncemented prosthesis. (a) Identification. A knee joint femoral (hemi-knee...
Baum, Thomas; Joseph, Gabby B; Arulanandan, Ahilan; Nardo, Lorenzo; Virayavanich, Warapat; Carballido-Gamio, Julio; Nevitt, Michael C; Lynch, John; McCulloch, Charles E; Link, Thomas M
2012-02-01
To evaluate the association of magnetic resonance imaging (MRI)-based knee cartilage T2 measurements and focal knee lesions with knee pain in knees without radiographic osteoarthritis (OA) among subjects with OA risk factors. We studied the right knees of 126 subjects from the Osteoarthritis Initiative database. We randomly selected 42 subjects ages 45-55 years with OA risk factors, right knee pain (Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC] pain score ≥5), no left knee pain (WOMAC pain score 0), and no radiographic OA (Kellgren/Lawrence [K/L] score ≤1) in the right knee. We also selected 2 comparison groups: 42 subjects without knee pain in either knee and 42 with bilateral knee pain. Both groups were frequency matched to subjects with right knee pain only by sex, age, body mass index, and K/L score. All of the subjects underwent 3T MRI of the right knee. Focal knee lesions were assessed and cartilage T2 measurements were performed. Prevalences of meniscal, bone marrow, and ligamentous lesions and joint effusion were not significantly different between the groups (P > 0.05), while cartilage lesions were more frequent in subjects with right knee pain only compared to subjects without knee pain (P < 0.05). T2 values averaged over all of the compartments were similar in subjects with right knee pain only (mean ± SD 34.4 ± 1.8 msec) and in subjects with bilateral knee pain (mean ± SD 34.7 ± 4.7 msec), but were significantly higher compared to subjects without knee pain (mean ± SD 32.4 ± 1.8 msec; P < 0.05). These results suggest that elevated cartilage T2 values are associated with findings of pain in the early phase of OA, whereas among morphologic knee abnormalities only knee cartilage lesions are significantly associated with knee pain status. Copyright © 2012 by the American College of Rheumatology.
Injury Prevention and Performance Enhancement in 101st Airbourne Soldiers
2012-02-01
those of elite athletes, with similar performance and nutrition needs. Dietary recommendations have been developed for the optimal amount of...2005. 33(3): p. 415-23. 10. Alonso AC, Greve JM, and Camanho GL: Evaluating the center of gravity of dislocations in soccer players with and without...Pietila T, and Werner S: Risk factors for leg injuries in female soccer players : a prospective investigation during one out-door season. Knee Surg
21 CFR 888.3590 - Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint tibial (hemi-knee) metallic resurfacing... Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis is a device intended to be implanted...
21 CFR 888.3580 - Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellar (hemi-knee) metallic... § 888.3580 Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis is a device made of...
2013-01-01
Background Knee extensor strength and knee extension range of motion (ROM) are important predictors of physical function in patients with a total knee arthroplasty (TKA). However, the relationship between the two knee measures remains unclear. The purpose of this study was to examine whether changes in knee extensor strength mediate the association between changes in knee extension ROM and self-report physical function. Methods Data from 441 patients with a TKA were collected preoperatively and 6 months postoperatively. Self-report measure of physical function was assessed by the Short Form 36 (SF-36) questionnaire. Knee extensor strength was measured by handheld dynamometry and knee extension ROM by goniometry. A bootstrapped cross product of coefficients approach was used to evaluate mediation effects. Results Mediation analyses, adjusted for clinicodemographic measures, revealed that the association between changes in knee extension ROM and SF-36 physical function was mediated by changes in knee extensor strength. Conclusions In patients with TKA, knee extensor strength mediated the influence of knee extension ROM on physical function. These results suggest that interventions to improve the range of knee extension may be useful in improving knee extensor performance. PMID:23332039
Beaudreuil, Johann; Bendaya, Samy; Faucher, Marc; Coudeyre, Emmanuel; Ribinik, Patricia; Revel, Michel; Rannou, François
2009-12-01
To develop clinical practice guidelines concerning the use of bracing--rest orthosis, knee sleeves and unloading knee braces--for knee osteoarthritis. The French Physical Medicine and Rehabilitation Society (SOFMER) methodology, associating a systematic literature review, collection of everyday clinical practice, and external review by multidisciplinary expert panel, was used. Few high-level studies of bracing for knee osteoarthritis were found. No evidence exists for the effectiveness of rest orthosis. Evidence for knee sleeves suggests that they decrease pain in knee osteoarthritis, and their use is associated with subjective improvement. These actions do not appear to depend on a local thermal effect. The effectiveness of knee sleeves for disability is not demonstrated for knee osteoarthritis. Short- and mid-term follow-up indicates that valgus knee bracing decreases pain and disability in medial knee osteoarthritis, appears to be more effective than knee sleeves, and improves quality of life, knee proprioception, quadriceps strength, and gait symmetry, and decreases compressive loads in the medial femoro-tibial compartment. However, results of response to valgus knee bracing remain inconsistent; discomfort and side effects can result. Thrombophlebitis of the lower limbs has been reported with the braces. Braces, whatever kind, are infrequently prescribed in clinical practice for osteoarthritis of the lower limbs. Modest evidence exists for the effectiveness of bracing--rest orthosis, knee sleeves and unloading knee braces--for knee osteoarthritis, with only low level recommendations for its use. Braces are prescribed infrequently in French clinical practice for osteoarthritis of the knee. Randomized clinical trials concerning bracing in knee osteoarthritis are still necessary.
Cao, Wujing; Yu, Hongliu; Zhao, Weiliang; Meng, Qiaoling; Chen, Wenming
2018-04-20
The microprocessor-controlled prosthetic knees have been introduced to transfemoral amputees due to advances in biomedical engineering. A body of scientific literature has shown that the microprocessor-controlled prosthetic knees improve the gait and functional abilities of persons with transfemoral amputation. The aim of this study was to propose a new microprocessor-controlled prosthetic knee (MPK) and compare it with non-microprocessor-controlled prosthetic knees (NMPKs) under different walking speeds. The microprocessor-controlled prosthetic knee (i-KNEE) with hydraulic damper was developed. The comfortable self-selected walking speeds of 12 subjects with i-KNEE and NMPK were obtained. The maximum swing flexion knee angle and gait symmetry were compared in i-KNEE and NMPK condition. The comfortable self-selected walking speeds of some subjects were higher with i-KNEE while some were not. There was no significant difference in comfortable self-selected walking speed between the i-KNEE and the NMPK condition (P= 0.138). The peak prosthetic knee flexion during swing in the i-KNEE condition was between sixty and seventy degree under any walking speed. In the NMPK condition, the maximum swing flexion knee angle changed significantly. And it increased with walking speed. There is no significant difference in knee kinematic symmetry when the subjects wear the i-KNEE or NMPK. The results of this study indicated that the new microprocessor-controlled prosthetic knee was suitable for transfemoral amputees. The maximum swing flexion knee angle under different walking speeds showed different properties in the NMPK and i-KNEE condition. The i-KNEE was more adaptive to speed changes. There was little difference of comfortable self-selected walking speed between i-KNEE and NMPK condition.
Goodin, Burel R.; Glover, Toni L.; Sotolongo, Adriana; King, Christopher D.; Sibille, Kimberly T.; Herbert, Matthew S.; Cruz-Almeida, Yenisel; Sanden, Shelley H.; Staud, Roland; Redden, David T.; Bradley, Laurence A.; Fillingim, Roger B.
2012-01-01
Dispositional optimism has been shown to beneficially influence various experimental and clinical pain experiences. One possibility that may account for decreased pain sensitivity among individuals who report greater dispositional optimism is less use of maladaptive coping strategies like pain catastrophizing, a negative cognitive/affective response to pain. An association between dispositional optimism and conditioned pain modulation (CPM), a measure of endogenous pain inhibition, has previously been reported. However, it remains to be determined whether dispositional optimism is also associated with temporal summation (TS), a measure of endogenous pain facilitation. The current study examined whether pain catastrophizing mediated the association between dispositional optimism and TS among 140 older, community-dwelling adults with symptomatic knee osteoarthritis. Individuals completed measures of dispositional optimism and pain catastrophizing. TS was then assessed using a tailored heat pain stimulus on the forearm. Greater dispositional optimism was significantly related to lower levels of pain catastrophizing and TS. Bootstrapped confidence intervals revealed that less pain catastrophizing was a significant mediator of the relation between greater dispositional optimism and diminished TS. These findings support the primary role of personality characteristics such as dispositional optimism in the modulation of pain outcomes by abatement of endogenous pain facilitation and less use of catastrophizing. PMID:23218934
Bright, Philip; Hambly, Karen
2018-04-26
The use of electronic health (eHealth) and Web-based resources for patients with knee pain is expanding. Padlet is an online noticeboard that can facilitate patient interaction by posting virtual “sticky notes.” The primary aim of this study was to determine feasibility of patients in a 6-week knee exercise program using Padlet as an online forum for self-reporting on outcome progression. Undergraduate manual therapy students were recruited as part of a 6-week study into knee conditioning. Participants were encouraged to post maximum effort readings from quadriceps and gluteal home exercises captured from standard bathroom scales on a bespoke Padlet. Experience and progression reporting were encouraged. Posted data were analyzed for association between engagement, entry frequency, and participant characteristics. Individual data facilitated single-subject, multiple-baseline analysis using statistical process control. Experiential narrative was analyzed thematically. Nineteen participants were recruited (47%, 9/19 female); ages ranged from 19 to 53 years. Twelve individuals (63%) opted to engage with the forum (range 4-40 entries), with five (42%) reporting across all 6 weeks. Gender did not influence reporting (odds ratio [OR] 0.76, 95% CI 0.06-6.93). No significant difference manifested between body mass index and engagement P=.46); age and entry frequency did not correlate (R 2 =.054, 95% CI –0.42 to 0.51, P=.83). Statistically significant conditioning profiles arose in single participants. Themes of pain, mitigation, and response were inducted from the experiences posted. Patients will engage with an online forum for reporting progress when undertaking exercise programs. In contrast to related literature, no significant association was found with reporting and gender, age, or body mass index. Individual posted data allowed multiple-baseline analysis and experiential induction from participants. Conditioning responses were evident on visual inspection. The importance of individualized visual data to patients and the role of forums in monitoring patients’ progress in symptomatic knee pain populations need further consideration. ©Philip Bright, Karen Hambly. Originally published in JMIR Rehabilitation and Assistive Technology (http://rehab.jmir.org), 26.04.2018.
Verheul, Jasper; Clansey, Adam C; Lake, Mark J
2017-03-01
It remains to be determined whether running training influences the amplitude of lower limb muscle activations before and during the first half of stance and whether such changes are associated with joint stiffness regulation and usage of stored energy from tendons. Therefore, the aim of this study was to investigate neuromuscular and movement adaptations before and during landing in response to running training across a range of speeds. Two groups of high mileage (HM; >45 km/wk, n = 13) and low mileage (LM; <15 km/wk, n = 13) runners ran at four speeds (2.5-5.5 m/s) while lower limb mechanics and electromyography of the thigh muscles were collected. There were few differences in prelanding activation levels, but HM runners displayed lower activations of the rectus femoris, vastus medialis, and semitendinosus muscles postlanding, and these differences increased with running speed. HM runners also demonstrated higher initial knee stiffness during the impact phase compared with LM runners, which was associated with an earlier peak knee flexion velocity, and both were relatively unchanged by running speed. In contrast, LM runners had higher knee stiffness during the slightly later weight acceptance phase and the disparity was amplified with increases in speed. It was concluded that initial knee joint stiffness might predominantly be governed by tendon stiffness rather than muscular activations before landing. Estimated elastic work about the ankle was found to be higher in the HM runners, which might play a role in reducing weight acceptance phase muscle activation levels and improve muscle activation efficiency with running training. NEW & NOTEWORTHY Although neuromuscular factors play a key role during running, the influence of high mileage training on neuromuscular function has been poorly studied, especially in relation to running speed. This study is the first to demonstrate changes in neuromuscular conditioning with high mileage training, mainly characterized by lower thigh muscle activation after touch down, higher initial knee stiffness, and greater estimates of energy return, with adaptations being increasingly evident at faster running speeds. Copyright © 2017 the American Physiological Society.
Optimized Plane Wave Imaging for Fast and High-Quality Ultrasound Imaging.
Jensen, Jonas; Stuart, Matthias Bo; Jensen, Jorgen Arendt
2016-11-01
This paper presents a method for optimizing parameters affecting the image quality in plane wave imaging. More specifically, the number of emissions and steering angles is optimized to attain the best images with the highest frame rate possible. The method is applied to a specific problem, where image quality for a λ -pitch transducer is compared with a λ /2-pitch transducer. Grating lobe artifacts for λ -pitch transducers degrade the contrast in plane wave images, and the impact on frame rate is studied. Field II simulations of plane wave images are made for all combinations of the parameters, and the optimal setup is selected based on Pareto optimality. The optimal setup for a simulated 4.1-MHz λ -pitch transducer uses 61 emissions and a maximum steering angle of 20° for depths from 0 to 60 mm. The achieved lateral full-width at half-maximum (FWHM) is 1.5λ and the contrast is -29 dB for a scatterer at 9 mm ( 24λ ). Using a λ /2-pitch transducer and only 21 emissions within the same angle range, the image quality is improved in terms of contrast, which is -37 dB. For imaging in regions deeper than 25 mm ( 66λ ), only 21 emissions are optimal for both the transducers, resulting in a -36 dB contrast at 34 mm ( 90λ ). Measurements are performed using the experimental SARUS scanner connected to a λ -pitch and λ /2-pitch transducer. A wire phantom and a tissue mimicking phantom containing anechoic cysts are scanned and show the performance using the optimized sequences for the transducers. FWHM is 1.6λ and contrast is -25 dB for a wire at 9 mm using the λ -pitch transducer. For the λ /2-pitch transducer, contrast is -29 dB. In vivo scans of the carotid artery of a healthy volunteer show improved contrast and present fewer artifacts, when using the λ /2-pitch transducer compared with the λ -pitch. It is demonstrated with a frame rate, which is three times higher for the λ /2-pitch transducer.
Park, Joo Hyun; Choi, Sung Wook; Shin, Eun Ho; Park, Myung Hoon; Kim, Myung Ku
2017-01-01
Although intraarticular tranexamic acid (IA-TXA) administration or drainage clamping are popular methods used to reduce blood loss after total knee replacement (TKR), the protocol remains controversial. We aimed (1) to establish new protocols through investigating whether two methods, that is, low-dose (500 mg) IA-TXA plus 30-min drain clamping and drainage clamping for the first 3 h without IA-TXA, can reduce blood loss and blood transfusion after unilateral TKR and (2) to make recommendations related to clinical application. This study, conducted from September 2014 to June 2016 related to enrolled 95 patients with primary osteoarthritis who were to have a unilateral cemented TKR, was nonrandomized and retrospective. In group A, the drain was released following tourniquet deflation. In group B, 500-mg TXA was injected into the knee joint via a drain tube after fascia closure and the drain was clamped for the first 30 min to prevent leakage. In group C, the drain was clamped for the first 3-h postoperation. Demographic characteristics and clinical data were collected, including the levels of hematocrit (Hct), the total blood loss (TBL), drained blood volume (BV), the amount of blood transfused, and any complications that developed. We found a significantly lower postoperative TBL, drained BV, decreasing Hct level, and less transfused BV in the IA-TXA injection group (group B) and the 3-h drainage clamping group (group C) compared to the conventional negative drainage group (group A; p < 0.001). There was no significant difference between groups B and C ( p = 0.99). The drainage clamping method can be safer than IA-TXA administration in patients with risk factor of venous thromboembolic complication. Furthermore, the IA-TXA administration can be more optimal than drainage clamping in patients with high bleeding tendency or lateral retinacular release during TKR, who would be concerned about postoperative wound complication.
Massage Therapy for Osteoarthritis of the Knee: A Randomized Dose-Finding Trial
Perlman, Adam I.; Ali, Ather; Njike, Valentine Yanchou; Hom, David; Davidi, Anna; Gould-Fogerite, Susan; Milak, Carl; Katz, David L.
2012-01-01
Background In a previous trial of massage for osteoarthritis (OA) of the knee, we demonstrated feasibility, safety and possible efficacy, with benefits that persisted at least 8 weeks beyond treatment termination. Methods We performed a RCT to identify the optimal dose of massage within an 8-week treatment regimen and to further examine durability of response. Participants were 125 adults with OA of the knee, randomized to one of four 8-week regimens of a standardized Swedish massage regimen (30 or 60 min weekly or biweekly) or to a Usual Care control. Outcomes included the Western Ontario and McMaster Universities Arthritis Index (WOMAC), visual analog pain scale, range of motion, and time to walk 50 feet, assessed at baseline, 8-, 16-, and 24-weeks. Results WOMAC Global scores improved significantly (24.0 points, 95% CI ranged from 15.3–32.7) in the 60-minute massage groups compared to Usual Care (6.3 points, 95% CI 0.1–12.8) at the primary endpoint of 8-weeks. WOMAC subscales of pain and functionality, as well as the visual analog pain scale also demonstrated significant improvements in the 60-minute doses compared to usual care. No significant differences were seen in range of motion at 8-weeks, and no significant effects were seen in any outcome measure at 24-weeks compared to usual care. A dose-response curve based on WOMAC Global scores shows increasing effect with greater total time of massage, but with a plateau at the 60-minute/week dose. Conclusion Given the superior convenience of a once-weekly protocol, cost savings, and consistency with a typical real-world massage protocol, the 60-minute once weekly dose was determined to be optimal, establishing a standard for future trials. Trial Registration ClinicalTrials.gov NCT00970008 PMID:22347369
Henrotin, Yves; Gharbi, Myriam; Dierckxsens, Yvan; Priem, Fabian; Marty, Marc; Seidel, Laurence; Albert, Adelin; Heuse, Elisabeth; Bonnet, Valérie; Castermans, Caroline
2014-05-17
The management of osteoarthritis (OA) remains a challenge. There is a need not only for safe and efficient treatments but also for accurate and reliable biomarkers that would help diagnosis and monitoring both disease activity and treatment efficacy. Curcumin is basically a spice that is known for its anti-inflammatory properties. In vitro studies suggest that curcumin could be beneficial for cartilage in OA. The aim of this exploratory, non-controlled clinical trial was to evaluate the effects of bio-optimized curcumin in knee OA patients on the serum levels of specific biomarkers of OA and on the evaluation of pain. Twenty two patients with knee OA were asked to take 2x3 caps/day of bio-optimized curcumin (Flexofytol®) for 3 months. They were monitored after 7, 14, 28 and 84 days of treatment. Pain over the last 24 hours and global assessment of disease activity by the patient were evaluated using a visual analog scale (100 mm). The serum levels of Coll-2-1, Coll-2-1NO2, Fib3-1, Fib3-2, CRP, CTX-II and MPO were determined before and after 14 and 84 days of treatment. The treatment with curcumin was globally well tolerated. It significantly reduced the serum level of Coll2-1 (p<0.002) and tended to decrease CRP. No other significant difference was observed with the other biomarkers. In addition, curcumin significantly reduced the global assessment of disease activity by the patient. This study highlighted the potential effect of curcumin in knee OA patient. This effect was reflected by the variation of a cartilage specific biomarker, Coll2-1 that was rapidly affected by the treatment. These results are encouraging for the qualification of Coll2-1 as a biomarker for the evaluation of curcumin in OA treatment. NCT01909037 at clinicaltrials.gov.
Driban, Jeffrey B; Stout, Alina C; Duryea, Jeffrey; Lo, Grace H; Harvey, William F; Price, Lori Lyn; Ward, Robert J; Eaton, Charles B; Barbe, Mary F; Lu, Bing; McAlindon, Timothy E
2016-07-19
Accelerated knee osteoarthritis may be a unique subset of knee osteoarthritis, which is associated with greater knee pain and disability. Identifying risk factors for accelerated knee osteoarthritis is vital to recognizing people who will develop accelerated knee osteoarthritis and initiating early interventions. The geometry of an articular surface (e.g., coronal tibial slope), which is a determinant of altered joint biomechanics, may be an important risk factor for incident accelerated knee osteoarthritis. We aimed to determine if baseline coronal tibial slope is associated with incident accelerated knee osteoarthritis or common knee osteoarthritis. We conducted a case-control study using data and images from baseline and the first 4 years of follow-up in the Osteoarthritis Initiative. We included three groups: 1) individuals with incident accelerated knee osteoarthritis, 2) individuals with common knee osteoarthritis progression, and 3) a control group with no knee osteoarthritis at any time. We did 1:1:1 matching for the 3 groups based on sex. Weight-bearing, fixed flexion posterior-anterior knee radiographs were obtained at each visit. One reader manually measured baseline coronal tibial slope on the radiographs. Baseline femorotibial angle was measured on the radiographs using a semi-automated program. To assess the relationship between slope (predictor) and incident accelerated knee osteoarthritis or common knee osteoarthritis (outcomes) compared with no knee osteoarthritis (reference outcome), we performed multinomial logistic regression analyses adjusted for sex. The mean baseline slope for incident accelerated knee osteoarthritis, common knee osteoarthritis, and no knee osteoarthritis were 3.1(2.0), 2.7(2.1), and 2.6(1.9); respectively. A greater slope was associated with an increased risk of incident accelerated knee osteoarthritis (OR = 1.15 per degree, 95 % CI = 1.01 to 1.32) but not common knee osteoarthritis (OR = 1.04, 95 % CI = 0.91 to 1.19). These findings were similar when adjusted for recent injury. Among knees with varus malalignment a greater slope increases the odds of incident accelerated knee osteoarthritis; there is no significant relationship between slope and incident accelerated knee osteoarthritis among knees with normal alignment. Coronal tibial slope, particularly among knees with malalignment, may be an important risk factor for incident accelerated knee osteoarthritis.
NASA Astrophysics Data System (ADS)
Chen, Biao; Jing, Zhenxue; Smith, Andrew P.; Parikh, Samir; Parisky, Yuri
2006-03-01
Dual-energy contrast enhanced digital mammography (DE-CEDM), which is based upon the digital subtraction of low/high-energy image pairs acquired before/after the administration of contrast agents, may provide physicians physiologic and morphologic information of breast lesions and help characterize their probability of malignancy. This paper proposes to use only one pair of post-contrast low / high-energy images to obtain digitally subtracted dual-energy contrast-enhanced images with an optimal weighting factor deduced from simulated characteristics of the imaging chain. Based upon our previous CEDM framework, quantitative characteristics of the materials and imaging components in the x-ray imaging chain, including x-ray tube (tungsten) spectrum, filters, breast tissues / lesions, contrast agents (non-ionized iodine solution), and selenium detector, were systemically modeled. Using the base-material (polyethylene-PMMA) decomposition method based on entrance low / high-energy x-ray spectra and breast thickness, the optimal weighting factor was calculated to cancel the contrast between fatty and glandular tissues while enhancing the contrast of iodized lesions. By contrast, previous work determined the optimal weighting factor through either a calibration step or through acquisition of a pre-contrast low/high-energy image pair. Computer simulations were conducted to determine weighting factors, lesions' contrast signal values, and dose levels as functions of x-ray techniques and breast thicknesses. Phantom and clinical feasibility studies were performed on a modified Selenia full field digital mammography system to verify the proposed method and computer-simulated results. The resultant conclusions from the computer simulations and phantom/clinical feasibility studies will be used in the upcoming clinical study.
Yuuki, Arata; Muneta, Takeshi; Ohara, Toshiyuki; Sekiya, Ichiro; Koga, Hideyuki
2017-03-01
Associations of lateral/medial knee instability with anterior cruciate ligament (ACL) injury have not been thoroughly investigated. The purposes of this study were to investigate whether lateral/medial knee instability is associated with ACL injury, and to clarify relevant factors for lateral/medial knee instability in ACL-injured knees. One hundred and nineteen patients with unilateral ACL-injured knees were included. Lateral/medial knee instability was assessed with varus/valgus stress X-ray examination for both injured and uninjured knees by measuring varus/valgus angle, lateral/medial joint opening, and lateral/medial joint opening index. Manual knee instability tests for ACL were evaluated to investigate associations between lateral/medial knee instability and anterior and/or rotational instabilities. Patients' backgrounds were evaluated to identify relevant factors for lateral/medial knee instability. Damage on the lateral collateral ligament (LCL) on MRI was also evaluated. All parameters regarding lateral knee instability in injured knees were significantly greater than in uninjured knees. There were significant correlations between lateral knee instability and the Lachman test as well as the pivot shift test. Patients with LCL damage had significantly greater lateral joint opening than those without LCL damage on MRI. Sensitivity of LCL damage on MRI to lateral joint opening was 100%, while its specificity was 36%. No other relevant factors were identified. In medial knee instability, there were also correlations between medial knee instability and the Lachman test/pivot shift test. However, the correlations were weak and other parameters were not significant. Lateral knee instability was greater in ACL-deficient knees than in uninjured knees. Lateral knee instability was associated with ACL-related instabilities as well as LCL damage on MRI, whereas MRI had low specificity to lateral knee instability. On the other hand, the association of medial knee instability on ACL-related instability was less than that of lateral knee instability. Level IV, case series with no comparison group. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
An improved OpenSim gait model with multiple degrees of freedom knee joint and knee ligaments.
Xu, Hang; Bloswick, Donald; Merryweather, Andrew
2015-08-01
Musculoskeletal models are widely used to investigate joint kinematics and predict muscle force during gait. However, the knee is usually simplified as a one degree of freedom joint and knee ligaments are neglected. The aim of this study was to develop an OpenSim gait model with enhanced knee structures. The knee joint in this study included three rotations and three translations. The three knee rotations and mediolateral translation were independent, with proximodistal and anteroposterior translations occurring as a function of knee flexion/extension. Ten elastic elements described the geometrical and mechanical properties of the anterior and posterior cruciate ligaments (ACL and PCL), and the medial and lateral collateral ligaments (MCL and LCL). The three independent knee rotations were evaluated using OpenSim to observe ligament function. The results showed that the anterior and posterior bundles of ACL and PCL (aACL, pACL and aPCL, pPCL) intersected during knee flexion. The aACL and pACL mainly provided force during knee flexion and adduction, respectively. The aPCL was slack throughout the range of three knee rotations; however, the pPCL was utilised for knee abduction and internal rotation. The LCL was employed for knee adduction and rotation, but was slack beyond 20° of knee flexion. The MCL bundles were mainly used during knee adduction and external rotation. All these results suggest that the functions of knee ligaments in this model approximated the behaviour of the physical knee and the enhanced knee structures can improve the ability to investigate knee joint biomechanics during various gait activities.
Murray, Amanda M; Thomas, Abbey C; Armstrong, Charles W; Pietrosimone, Brian G; Tevald, Michael A
2015-12-01
Abnormal knee joint mechanics have been implicated in the pathogenesis and progression of knee osteoarthritis. Deficits in muscle function (i.e., strength and power) may contribute to abnormal knee joint loading. The associations between quadriceps strength, power and knee joint mechanics remain unclear in knee osteoarthritis. Three-dimensional motion analysis was used to collect peak knee joint angles and moments during the first 50% of stance phase of gait in 33 participants with knee osteoarthritis. Quadriceps strength and power were assessed using a knee extension machine. Strength was quantified as the one repetition maximum. Power was quantified as the peak power produced at 40-90% of the one repetition maximum. Quadriceps strength accounted for 15% of the variance in peak knee flexion angle (P=0.016). Quadriceps power accounted for 20-29% of the variance in peak knee flexion angle (P<0.05). Quadriceps power at 90% of one repetition maximum accounted for 9% of the variance in peak knee adduction moment (P=0.05). These data suggest that quadriceps power explains more variance in knee flexion angle and knee adduction moment during gait in knee osteoarthritis than quadriceps strength. Additionally, quadriceps power at multiple loads is associated with knee joint mechanics and therefore should be assessed at a variety of loads. Taken together, these results indicate that quadriceps power may be a potential target for interventions aimed at changing knee joint mechanics in knee osteoarthritis. Copyright © 2015 Elsevier Ltd. All rights reserved.
Yang, Dejin; Shao, Hongyi; Zhou, Yixin; Tang, Hao; Guo, Shengjie
2017-11-01
Lateral soft-tissue release can jeopardize the common peroneal nerve (CPN) in total knee arthroplasty for valgus knees. Previous studies reporting safe zones to protect the CPN were based on well-aligned knees. We conducted this study to compare the localization of the CPN in well-aligned knees and in valgus knees. We conducted a consecutive 3-dimensional radiographic study on magnetic resonance images of 58 well-aligned knees and 39 valgus knees. We measured the distance between the CPN and the tibia, as well as the mediolateral, anteroposterior, and angular location of the CPN. We compared the results between well-aligned knees and valgus knees. We found that there is an increased distance between the CPN and the tibia at the level of the tibial cut, but not at the joint line in valgus knees. It is safer to release the posterolateral capsule at the tibial side than at the level above this. The angular location and the mediolateral or anteroposterior location of the CPN in valgus knees are similar to those of well-aligned knees. The location of the CPN in valgus knees is similar to that in well-aligned knees. The previously reported safe zone in well-aligned knees is applicable in valgus knees to protect the CPN. Copyright © 2017 Elsevier Inc. All rights reserved.
Factors associated with gait speed recovery after total knee arthroplasty: A longitudinal study.
Pua, Yong-Hao; Seah, Felicia Jie-Ting; Clark, Ross Allan; Lian-Li Poon, Cheryl; Tan, John Wei-Ming; Chong, Hwei-Chi
2017-04-01
Gait speed limitations can remain significant issues after a total knee arthroplasty (TKA) but their associated factors are not well understood. This study aimed to identify the factors associated with acute gait speed recovery post-TKA. We performed a prospective longitudinal study of 1765 patients who underwent primary TKA between July 2013 and July 2015. At 4, 8, 12, and 16 weeks postsurgery, fast gait speed was measured. The factors associated with gait speed over time since TKA were identified using multivariable generalized least squares modeling. Lower postoperative quadriceps strength and knee flexion range of motion were closely associated with lower gait speed over time (0.084m/s, 0.064m/s, and 0.055m/s change in gait speed per interquartile range change in ipsilateral quadriceps strength, contralateral quadriceps strength, and knee flexion range of motion, respectively). Additional strong predictors of lower gait speed included older age (0.11m/s), lower levels of preoperative Short Form 36 physical function (0.066m/s), greater body mass (0.046m/s), and the preoperative use of a walking aid (overall P < 0.001). Patients who reported that they limited their daily activities due to a fear of falling also had poorer gait speed (0.033m/s and 0.054m/s slower gait speed for "Occasional" and "Often" categories, respectively, vs. "None"). Gait speed recovery post-TKA is driven by both physical and psychological factors, suggesting that identifying and treating the underlying physical and cognitive causes of gait speed limitations may be crucial to optimize functional recovery. Copyright © 2017 Elsevier Inc. All rights reserved.
Schrade, Stefan O; Nager, Yannik; Wu, Amy R; Gassert, Roger; Ijspeert, Auke
2017-07-01
Robotic lower limb exoskeletons are becoming increasingly popular in therapy and recreational use. However, most exoskeletons are still rather limited in their locomotion speed and the activities of daily live they can perform. Furthermore, they typically do not allow for a dynamic adaptation to the environment, as they are often controlled with predefined reference trajectories. Inspired by human leg stiffness modulation during walking, variable stiffness actuators increase flexibility without the need for more complex controllers. Actuation with adaptable stiffness is inspired by the human leg stiffness modulation during walking. However, this actuation principle also introduces the stiffness setpoint as an additional degree of freedom that needs to be coordinated with the joint trajectories. As a potential solution to this issue a bio-inspired controller based on a central pattern generator (CPG) is presented in this work. It generates coordinated joint torques and knee stiffness modulations to produce flexible and dynamic gait patterns for an exoskeleton with variable knee stiffness actuation. The CPG controller is evaluated and optimized in simulation using a model of the exoskeleton. The CPG controller produced stable and smooth gait for walking speeds from 0.4 m/s up to 1.57 m/s with a torso stabilizing force that simulated the use of crutches, which are commonly needed by exoskeleton users. Through the CPG, the knee stiffness intrinsically adapted to the frequency and phase of the gait, when the speed was changed. Additionally, it adjusted to changes in the environment in the form of uneven terrain by reacting to ground contact forces. This could allow future exoskeletons to be more adaptive to various environments, thus making ambulation more robust.
Ward, Rachel E; Beauchamp, Marla K; Latham, Nancy K; Leveille, Suzanne G; Percac-Lima, Sanja; Kurlinski, Laura; Ni, Pengsheng; Goldstein, Richard; Jette, Alan M; Bean, Jonathan F
2016-08-01
To identify neuromuscular impairments most predictive of unfavorable mobility outcomes in late life. Longitudinal cohort study. Research clinic. Community-dwelling primary care patients aged ≥65 years (N=391) with self-reported mobility modifications, randomly selected from a research registry. Not applicable. Categories of decline in and persistently poor mobility across baseline, 1 and 2 years of follow-up in the Lower-Extremity Function scales of the Late-Life Function and Disability Instrument. The following categories of impairment were assessed as potential predictors of mobility change: strength (leg strength), speed of movement (leg velocity, reaction time, rapid leg coordination), range of motion (ROM) (knee flexion/knee extension/ankle ROM), asymmetry (asymmetry of leg strength and knee flexion/extension ROM measures), and trunk stability (trunk extensor endurance, kyphosis). The largest effect sizes were found for baseline weaker leg strength (odds ratio [95% confidence interval]: 3.45 [1.72-6.95]), trunk extensor endurance (2.98 [1.56-5.70]), and slower leg velocity (2.35 [1.21-4.58]) predicting a greater likelihood of persistently poor function over 2 years. Baseline weaker leg strength, trunk extensor endurance, and restricted knee flexion motion also predicted a greater likelihood of decline in function (1.72 [1.10-2.70], 1.83 [1.13-2.95], and 2.03 [1.24-3.35], respectively). Older adults exhibiting poor mobility may be prime candidates for rehabilitation focused on improving these impairments. These findings lay the groundwork for developing interventions aimed at optimizing rehabilitative care and disability prevention, and highlight the importance of both well-recognized (leg strength) and novel impairments (leg velocity, trunk extensor muscle endurance). Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
The Use of Finite Element Analysis to Enhance Research and Clinical Practice in Orthopedics.
Pfeiffer, Ferris M
2016-02-01
Finite element analysis (FEA) is a very powerful tool for the evaluation of biomechanics in orthopedics. Finite element (FE) simulations can effectively and efficiently evaluate thousands of variables (such as implant variation, surgical techniques, and various pathologies) to optimize design, screening, prediction, and treatment in orthopedics. Additionally, FEA can be used to retrospectively evaluate and troubleshoot complications or failures to prevent similar future occurrences. Finally, FE simulations are used to evaluate implants, procedures, and techniques in a time- and cost-effective manner. In this work, an overview of the development of FE models is provided and an example application is presented to simulate knee biomechanics for a specimen with medial meniscus insufficiency. FE models require the development of the geometry of interest, determination of the material properties of the tissues simulated, and an accurate application of a numerical solver to produce an accurate solution and representation of the field variables. The objectives of this work are to introduce the reader to the application of FEA in orthopedic analysis of the knee joint. A brief description of the model development process as well as a specific application to the investigation of knee joint stability in geometries with normal or compromised medial meniscal attachment is included. Significant increases in stretch of the anterior cruciate ligament were predicted in specimens with medial meniscus insufficiency (such behavior was confirmed in corresponding biomechanical testing). It can be concluded from this work that FE analysis of the knee can provide significant new information with which more effective clinical decisions can be made. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
NASA Astrophysics Data System (ADS)
Yamazaki, Takaharu; Futai, Kazuma; Tomita, Tetsuya; Sato, Yoshinobu; Yoshikawa, Hideki; Tamura, Shinichi; Sugamoto, Kazuomi
2011-03-01
To achieve 3D kinematic analysis of total knee arthroplasty (TKA), 2D/3D registration techniques, which use X-ray fluoroscopic images and computer-aided design (CAD) model of the knee implant, have attracted attention in recent years. These techniques could provide information regarding the movement of radiopaque femoral and tibial components but could not provide information of radiolucent polyethylene insert, because the insert silhouette on X-ray image did not appear clearly. Therefore, it was difficult to obtain 3D kinemaitcs of polyethylene insert, particularly mobile-bearing insert that move on the tibial component. This study presents a technique and the accuracy for 3D kinematic analysis of mobile-bearing insert in TKA using X-ray fluoroscopy, and finally performs clinical applications. For a 3D pose estimation technique of the mobile-bearing insert in TKA using X-ray fluoroscopy, tantalum beads and CAD model with its beads are utilized, and the 3D pose of the insert model is estimated using a feature-based 2D/3D registration technique. In order to validate the accuracy of the present technique, experiments including computer simulation test were performed. The results showed the pose estimation accuracy was sufficient for analyzing mobile-bearing TKA kinematics (the RMS error: about 1.0 mm, 1.0 degree). In the clinical applications, seven patients with mobile-bearing TKA in deep knee bending motion were studied and analyzed. Consequently, present technique enables us to better understand mobile-bearing TKA kinematics, and this type of evaluation was thought to be helpful for improving implant design and optimizing TKA surgical techniques.
Strength Asymmetry and Landing Mechanics at Return to Sport after ACL Reconstruction
Schmitt, Laura C.; Paterno, Mark V.; Ford, Kevin R.; Myer, Gregory D.; Hewett, Timothy E.
2014-01-01
Purpose Evidence-based quadriceps femoris muscle (QF) strength guidelines for return to sport following anterior cruciate ligament (ACL) reconstruction are lacking. This study investigated the impact of QF strength asymmetry on knee landing biomechanics at the time of return to sport following ACL reconstruction. Methods Seventy-seven individuals (17.4 years) at the time of return to sport following primary ACL reconstruction (ACLR group) and 47 uninjured control individuals (17.0 years) (CTRL group) participated. QF strength was assessed and Quadriceps Index calculated (QI = [involved strength/uninvolved strength]*100%). The ACLR group was sub-divided based on QI: High Quadriceps (HQ, QI≥90%) and Low-Quadriceps (LQ, QI<85%). Knee kinematic and kinetic variables were collected during a drop vertical jump maneuver. Limb symmetry during landing, and discrete variables were compared among the groups with multivariate analysis of variance and linear regression analyses. Results The LQ group demonstrated worse asymmetry in all kinetic and ground reaction force variables compared to the HQ and CTRL groups, including reduced involved limb peak knee external flexion moments (p<.001), reduced involved limb (p=.003) and increased uninvolved limb (p=.005) peak vertical ground reaction forces, and higher uninvolved limb peak loading rates (p<.004). There were no differences in the landing patterns between the HQ and CTRL groups on any variable (p>.05). In the ACLR group, QF strength estimated limb symmetry during landing after controlling for graft type, meniscus injury, knee pain and symptoms. Conclusion At the time of return to sport, individuals post-ACL reconstruction with weaker QF demonstrate altered landing patterns. Conversely, those with nearly symmetrical QF strength demonstrate landing patterns similar to uninjured individuals. Consideration of an objective QF strength measure may aid clinical decision-making to optimize sports participation following ACL reconstruction. PMID:25373481
Rehabilitation (exercise and strength training) and osteoarthritis: A critical narrative review.
Nguyen, Christelle; Lefèvre-Colau, Marie-Martine; Poiraudeau, Serge; Rannou, François
2016-06-01
Rehabilitation is widely recommended in national and international guidelines for managing osteoarthritis (OA) in primary care settings. According to the 2014 OA Research Society International (OARSI) recommendations, rehabilitation is even considered the core treatment of OA and is recommended for all patients. Rehabilitation for OA widely includes land- and water-based exercise, strength training, weight management, self-management and education, biomechanical interventions, and physically active lifestyle. We performed a critical narrative review of the efficacy and safety of rehabilitation for managing OA and discuss evidence-based international recommendations. The process of article selection was unsystematic. Articles were selected based on authors' expertise, self-knowledge, and reflective practice. For the purpose of the review, we focused on land- and water-based exercise and strength training for knee, hip and hand OA. Other aspects of rehabilitation in OA are treated elsewhere in this special issue. Exercise therapy is widely recommended for managing knee, hip and hand OA. However, the level of evidence varies according to OA location. Overall, consistent evidence suggests that exercise therapy and specific strengthening exercise or strength training for the lower limb reduce pain and improve physical function in knee OA. Evidence for other OA sites are less consistent. Therefore, because of the lack of specific studies, recommendations for hip and hand OA are mainly derived from studies of knee OA. In addition, no recommendations have been established regarding the exercise regimen. The efficacy and safety of exercise therapy and strength training need to be further evaluated in randomized controlled trials of patients with hip and hand OA. The optimal delivery of exercise programs also has to be more clearly defined. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Gandhi, Rikesh; Silverman, Edward; Courtney, Paul M; Lee, Gwo-Chin
2017-09-01
Identification of the infecting organism is critical to the successful management of deep prosthetic joint infections about the hip and the knee. However, the number of culture specimens and which culture specimens are best to identify these organisms is unknown. We evaluated 113 consecutive patients with infected total hip and total knee arthroplasties and correlated the type of culture specimen and number of specimens taken during surgery to the likelihood of a positive culture result. From these data, we subsequently developed a model to maximize culture yield at the time of surgical intervention. After exclusions, 74 patients meeting the Musculoskeletal Infection Society criteria were left for final analysis. From this cohort, 63 of 74 patients had a positive culture result (85%). The odds of a fluid culture result being positive was 35 of 47 (0.75), whereas the likelihood of tissue cultures yielding a positive result was 164 of 245 (0.67; P = .313). The sample designated "best culture" specimen was the only culture with a positive result in 1 of 48 cases in which a best culture was identified. The optimal number of cultures needed to yield a positive test result was 4 (specificity = 0.61 and sensitivity = 0.63). Increasing the number of samples increases sensitivity but reduces specificity. A minimum of 4 tissue cultures from representative areas is necessary to maximize the chance of identifying the infecting organism during management of the infected total hip and total knee arthroplasties. The designation of the best culture specimen for additional testing is arbitrary and may not be clinically efficacious. Copyright © 2017 Elsevier Inc. All rights reserved.
Sugiura, Hiroki; Demura, Shinichi
2012-01-01
This study aimed to examine the effect of subjective knee-joint pain on the laterality of knee extension strength and gait in elderly women. The subjects were 144 elderly women (62-94 years old; mean age 76.2±6.0 years; ±S.D.) who were divided into the following groups: 81 persons without knee-pain (no knee-pain group), 39 persons with the subjective pain in right or left knee (single knee-pain group), and 24 persons with the subjective pain in both knees (double knee-pain group). The subjects took a knee extension strength test and a 12 m maximum effort walk test. Knee extension strength, stance time, swing time, stride length, step length and swing speed were selected as parameters. A significant laterality was found in knee extension strength only in the one knee-pain group. The laterality of gait parameters was not found in all groups. In conclusion, elderly women who can perform daily living activity independently, even though having subjective pain in either knee or laterality in knee extension strength exertion show little laterality of gait during short distance walking. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Lemaire, Edward D; Samadi, Reza; Goudreau, Louis; Kofman, Jonathan
2013-01-01
A linear piston hydraulic angular-velocity-based control knee joint was designed for people with knee-extensor weakness to engage knee-flexion resistance when knee-flexion angular velocity reaches a preset threshold, such as during a stumble, but to otherwise allow free knee motion. During mechanical testing at the lowest angular-velocity threshold, the device engaged within 2 degrees knee flexion and resisted moment loads of over 150 Nm. The device completed 400,000 loading cycles without mechanical failure or wear that would affect function. Gait patterns of nondisabled participants were similar to normal at walking speeds that produced below-threshold knee angular velocities. Fast walking speeds, employed purposely to attain the angular-velocity threshold and cause knee-flexion resistance, reduced maximum knee flexion by approximately 25 degrees but did not lead to unsafe gait patterns in foot ground clearance during swing. In knee collapse tests, the device successfully engaged knee-flexion resistance and stopped knee flexion with peak knee moments of up to 235.6 Nm. The outcomes from this study support the potential for the linear piston hydraulic knee joint in knee and knee-ankle-foot orthoses for people with lower-limb weakness.
Zhang, Hangzhou; Sun, Yu; Han, Xiaorui; Wang, Yanfeng; Wang, Lin; Alquhali, Ali; Bai, Xizhuang
2014-07-01
In cases of chronic anterior cruciate ligament (ACL)-medial collateral ligament (MCL) lesions, nonoperative treatment of the MCL lesion may lead to chronic valgus instability and rotatory instability. The optimal management for patients who have combined ACL-MCL injuries remains controversial. To present a case series of 21 patients who underwent simultaneous ACL-MCL reconstruction with a 2- to 5-year follow-up. Case series; Level of evidence, 4. From October 2007 to December 2010, a total of 21 patients with chronic ACL-MCL injuries, for which the 2 ligaments were reconstructed during the same surgical procedure, were studied. All patients were available for follow-up for at least 2 years. The International Knee Documentation Committee (IKDC) subjective knee scores, valgus and sagittal stability, anteromedial rotatory stability, range of motion, and complications were assessed both preoperatively and postoperatively. At follow-up, valgus and sagittal laxity were not observed in any of the patients. The mean medial knee opening was significantly reduced to 0.80 ± 0.96 mm (range, -1.2 to 2.6 mm) postoperatively compared with 8.0 ± 1.3 mm (range, 6.1 to 10.7 mm) preoperatively (P < .01). The mean postoperative side-to-side difference measured with the KT-1000 arthrometer was reduced to 0.8 ± 0.9 mm (range, -1.2 to 2.3 mm) compared with 8.4 ± 1.6 mm (range, 6.2 to 13.2 mm) preoperatively (P < .01). Preoperative anteromedial instability was seen in 71% of patients (15/21), whereas none of the patients had anteromedial rotatory instability at the last follow-up. The mean IKDC subjective score improved overall from 45.3 ± 12.0 (range, 28.7-69.0) preoperatively to 87.7 ± 8.2 (range, 65.5-100.0) at the last follow-up (P < .01). Most patients (20/21) had normal or nearly normal range of motion of the knee joint; only 1 patient (5%) had a limitation of flexion of 15° compared with the contralateral knee at the last follow-up. In patients with chronic ACL-MCL lesions, simultaneous reconstruction of the ACL and MCL can significantly improve the medial, sagittal, and rotatory stability of the knee at short-term follow-up. © 2014 The Author(s).
2013-01-01
Background Formal rehabilitation programs are often assumed to be required after total knee arthroplasty to optimize patient recovery. Inpatient rehabilitation is a costly rehabilitation option after total knee arthroplasty and, in Australia, is utilized most frequently for privately insured patients. With the exception of comparisons with domiciliary services, no randomized trial has compared inpatient rehabilitation to any outpatient based program. The Hospital Inpatient versus HOme (HIHO) study primarily aims to determine whether 10 days of post-acute inpatient rehabilitation followed by a hybrid home program provides superior recovery of functional mobility on the 6-minute walk test (6MWT) compared to a hybrid home program alone following total knee arthroplasty. Secondarily, the trial aims to determine whether inpatient rehabilitation yields superior recovery in patient-reported function. Methods/Design This is a two-arm parallel randomized controlled trial (RCT), with a third, non-randomized, observational group. One hundred and forty eligible, consenting participants who have undergone a primary total knee arthroplasty at a high-volume joint replacement center will be randomly allocated when cleared for discharge from acute care to either 10 days of inpatient rehabilitation followed by usual care (a 6-week hybrid home program) or to usual care. Seventy participants in each group (140 in total) will provide 80% power at a significance level of 5% to detect an increase in walking capacity from 400 m to 460 m between the Home and Inpatient groups, respectively, in the 6MWT at 6 months post-surgery, assuming a SD of 120 m and a drop-out rate of <10%. The outcome assessor will assess participants at 10, 26 and 52 weeks post-operatively, and will remain blind to group allocation for the duration of the study, as will the statistician. Participant preference for rehabilitation mode stated prior to randomization will be accounted for in the analysis together with any baseline differences in potentially confounding characteristics as required. Discussion The HIHO Trial will be the first RCT to investigate the efficacy of inpatient rehabilitation compared to any outpatient alternative following total knee arthroplasty. Trial registration U.S. National Institutes of Health Clinical Trials Registry (http://clinicaltrials.gov) ref: NCT01583153 PMID:24341348
Clément, Julien; Dumas, Raphaël; Hagemeister, Nicola; de Guise, Jaques A
2017-01-01
Knee joint kinematics derived from multi-body optimisation (MBO) still requires evaluation. The objective of this study was to corroborate model-derived kinematics of osteoarthritic knees obtained using four generic knee joint models used in musculoskeletal modelling - spherical, hinge, degree-of-freedom coupling curves and parallel mechanism - against reference knee kinematics measured by stereo-radiography. Root mean square errors ranged from 0.7° to 23.4° for knee rotations and from 0.6 to 9.0 mm for knee displacements. Model-derived knee kinematics computed from generic knee joint models was inaccurate. Future developments and experiments should improve the reliability of osteoarthritic knee models in MBO and musculoskeletal modelling.
2013-01-01
Background UC-II contains a patented form of undenatured type II collagen derived from chicken sternum. Previous preclinical and clinical studies support the safety and efficacy of UC-II in modulating joint discomfort in osteoarthritis and rheumatoid arthritis. The purpose of this study was to assess the efficacy and tolerability of UC-II in moderating joint function and joint pain due to strenuous exercise in healthy subjects. Methods This randomized, double-blind, placebo-controlled study was conducted in healthy subjects who had no prior history of arthritic disease or joint pain at rest but experienced joint discomfort with physical activity. Fifty-five subjects who reported knee pain after participating in a standardized stepmill performance test were randomized to receive placebo (n = 28) or the UC-II (40 mg daily, n = 27) product for 120 days. Joint function was assessed by changes in degree of knee flexion and knee extension as well as measuring the time to experiencing and recovering from joint pain following strenuous stepmill exertion. Results After 120 days of supplementation, subjects in the UC-II group exhibited a statistically significant improvement in average knee extension compared to placebo (81.0 ± 1.3º vs 74.0 ± 2.2º; p = 0.011) and to baseline (81.0 ± 1.3º vs 73.2 ± 1.9º; p = 0.002). The UC-II cohort also demonstrated a statistically significant change in average knee extension at day 90 (78.8 ± 1.9º vs 73.2 ± 1.9º; p = 0.045) versus baseline. No significant change in knee extension was observed in the placebo group at any time. It was also noted that the UC-II group exercised longer before experiencing any initial joint discomfort at day 120 (2.8 ± 0.5 min, p = 0.019), compared to baseline (1.4 ± 0.2 min). By contrast, no significant changes were seen in the placebo group. No product related adverse events were observed during the study. At study conclusion, five individuals in the UC-II cohort reported no pain during or after the stepmill protocol (p = 0.031, within visit) as compared to one subject in the placebo group. Conclusions Daily supplementation with 40 mg of UC-II was well tolerated and led to improved knee joint extension in healthy subjects. UC-II also demonstrated the potential to lengthen the period of pain free strenuous exertion and alleviate the joint pain that occasionally arises from such activities. PMID:24153020
Lugo, James P; Saiyed, Zainulabedin M; Lau, Francis C; Molina, Jhanna Pamela L; Pakdaman, Michael N; Shamie, Arya Nick; Udani, Jay K
2013-10-24
UC-II contains a patented form of undenatured type II collagen derived from chicken sternum. Previous preclinical and clinical studies support the safety and efficacy of UC-II in modulating joint discomfort in osteoarthritis and rheumatoid arthritis. The purpose of this study was to assess the efficacy and tolerability of UC-II in moderating joint function and joint pain due to strenuous exercise in healthy subjects. This randomized, double-blind, placebo-controlled study was conducted in healthy subjects who had no prior history of arthritic disease or joint pain at rest but experienced joint discomfort with physical activity. Fifty-five subjects who reported knee pain after participating in a standardized stepmill performance test were randomized to receive placebo (n = 28) or the UC-II (40 mg daily, n = 27) product for 120 days. Joint function was assessed by changes in degree of knee flexion and knee extension as well as measuring the time to experiencing and recovering from joint pain following strenuous stepmill exertion. After 120 days of supplementation, subjects in the UC-II group exhibited a statistically significant improvement in average knee extension compared to placebo (81.0 ± 1.3º vs 74.0 ± 2.2º; p = 0.011) and to baseline (81.0 ± 1.3º vs 73.2 ± 1.9º; p = 0.002). The UC-II cohort also demonstrated a statistically significant change in average knee extension at day 90 (78.8 ± 1.9º vs 73.2 ± 1.9º; p = 0.045) versus baseline. No significant change in knee extension was observed in the placebo group at any time. It was also noted that the UC-II group exercised longer before experiencing any initial joint discomfort at day 120 (2.8 ± 0.5 min, p = 0.019), compared to baseline (1.4 ± 0.2 min). By contrast, no significant changes were seen in the placebo group. No product related adverse events were observed during the study. At study conclusion, five individuals in the UC-II cohort reported no pain during or after the stepmill protocol (p = 0.031, within visit) as compared to one subject in the placebo group. Daily supplementation with 40 mg of UC-II was well tolerated and led to improved knee joint extension in healthy subjects. UC-II also demonstrated the potential to lengthen the period of pain free strenuous exertion and alleviate the joint pain that occasionally arises from such activities.
Knee Injuries and Disability Among Enlisted Males in the U.S. Navy.
1985-05-01
derangements (30.8%), and Chondromalacia (19.9%) were the most common knee diagnoses among the 1974 cohort. Estimated annual age- (length-of-service- and pay...ICDA-8 Code Description 724.5 Other knee derangement 729.6 Loose body in knee 729.7 Chondromalacia of knee 729.9 other diseases of knee 822.0, 822.1...injury categories. Dislocated knees (35.2%), other knee derangements (30.8%), and Chondromalacia (19.9) were the most common knee diagnoses identified in
Feeley, Iain; Hegarty, Aidan; Hickey, Anne; Glynn, Aaron
2016-08-01
Mechanical guides in total knee arthroplasty are divided into intramedullary and extramedullary systems, designed to give accurate reference, to enable the surgeon to perform a tibial cut which is perpendicular to the mechanical axis. We conducted a systematic review and meta-analysis of levels 1 and 2 published data which directly compares the two methods of alignment, with outcomes of interest being the mean tibial component angle to the mechanical axis and the number of outliers from the optimal range. The PRISMA (preferred reporting items for systematic reviews and meta-analysis) guidance was followed. A search was conducted of online databases Medline PubMed; EMBASE; ISI Web of Science, and the Cochrane library, using the Boolean search string ([intramedullary OR extramedullary] AND knee AND [arthroplasty OR replacement]). Numerical data pertaining to tibial component alignment (TCA), the mechanical tibiofemoral angle, the tibial slope, and the number of outliers from optimal TCA were collated, and used to establish pooled results. No constraints on the search in terms of year of publication or language were instituted. Intrastudy bias was assessed using the Jadad score for randomized controlled trials and the Newcastle Ottawa score for prospective cohort studies. A total of 1,896 titles were reviewed. Following abstract review and full review of relevant articles, 10 publications were included for analysis, of which 8 were suitable to include for meta-analysis. No trials showed a significant difference in the mean TCA. Two trials showed an increased number of outliers in the extramedullary group and two studies showed an increased number of outliers in the intramedullary group. Pooled data from studies which included these outcomes showed no advantage for either system in limiting the number of outliers from the optimal TCA (relative risk, 0.99; 95% confidence interval [CI], 0.87-1.14; p = 0.004), and no significant difference in mean TCA (standardized mean difference, -0.07; 95% CI, -0.22 to 0.08; p = 0.000). Based on our results, no advantage can be attributed to the type of mechanical guide used in obtaining an adequate tibial cut. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Guo, Ruolin; Zhou, Quan; Proulx, Steven T.; Wood, Ronald; Ji, Rui-Cheng; Ritchlin, Christopher T.; Pytowski, Bronislaw; Zhu, Zhenping; Wang, Yong-Jun; Schwarz, Edward M.; Xing, Lianping
2009-01-01
Object Investigation of the effect of lymphatic inhibition on joint and draining lymph node pathology during the course of arthritis progression in mice. Method TNF transgenic (TNF-Tg) mice were used as a model of chronic inflammatory arthritis. Mice received contrast enhanced MRI to obtain ankle and knee joint synovial volumes and draining popliteal lymph node (PLN) volumes before and 8 weeks after treatment with VEGFR-3 or VEGFR-2 neutralizing antibodies, or isotype IgG. The animals were subjected to near-infrared lymphatic imaging to determine the effect of VEGFR-3 neutralization on lymph transport from paws to draining PLNs prior to sacrifice. Lymphatic vessel formation and morphology of joints and PLNs were examined by histology, immunohistochemistry, and RT-PCR. Results Compared to IgG treatment, VEGFR-3 neutralizing antibody treatment significantly decreased the size of PLNs, the number of lymphatic vessels in joints and PLNs, the lymphatic drainage from paws to PLNs, and the number of VEGF-C expressing CD11b+ myeloid cells in PLNs. However, it increased the synovial volumes and inflammatory area in ankle and knee joints. VEGFR-2 neutralizing antibody, in contrast, inhibited both lymphangiogenesis and joint inflammation. Conclusion Lymphangiogenesis and lymphatic drainage are reciprocally related to the severity of joint lesions during the development of chronic arthritis. Lymphatic drainage plays a beneficial role in controlling the progression of chronic inflammation. PMID:19714652
Advanced concepts in knee arthrodesis.
Wood, Jennifer H; Conway, Janet D
2015-03-18
The aim is to describe advanced strategies that can be used to diagnose and treat complications after knee arthrodesis and to describe temporary knee arthrodesis to treat infected knee arthroplasty. Potential difficult complications include nonunited knee arthrodesis, limb length discrepancy after knee arthrodesis, and united but infected knee arthrodesis. If a nonunited knee arthrodesis shows evidence of implant loosening or failure, then bone grafting the nonunion site as well as exchange intramedullary nailing and/or supplemental plate fixation are recommended. If symptomatic limb length discrepancy cannot be satisfactorily treated with a shoe lift, then the patient should undergo tibial lengthening over nail with a monolateral fixator or exchange nailing with a femoral internal lengthening device. If a united knee arthrodesis is infected, the nail must be removed. Then the surgeon has the option of replacing it with a long, antibiotic cement-coated nail. The authors also describe temporary knee arthrodesis for infected knee arthroplasty in patients who have the potential to undergo insertion of a new implant. The procedure has two goals: eradication of infection and stabilization of the knee. A temporary knee fusion can be accomplished by inserting both an antibiotic cement-coated knee fusion nail and a static antibiotic cement-coated spacer. These advanced techniques can be helpful when treating difficult complications after knee arthrodesis and treating cases of infected knee arthroplasty.
Advanced concepts in knee arthrodesis
Wood, Jennifer H; Conway, Janet D
2015-01-01
The aim is to describe advanced strategies that can be used to diagnose and treat complications after knee arthrodesis and to describe temporary knee arthrodesis to treat infected knee arthroplasty. Potential difficult complications include nonunited knee arthrodesis, limb length discrepancy after knee arthrodesis, and united but infected knee arthrodesis. If a nonunited knee arthrodesis shows evidence of implant loosening or failure, then bone grafting the nonunion site as well as exchange intramedullary nailing and/or supplemental plate fixation are recommended. If symptomatic limb length discrepancy cannot be satisfactorily treated with a shoe lift, then the patient should undergo tibial lengthening over nail with a monolateral fixator or exchange nailing with a femoral internal lengthening device. If a united knee arthrodesis is infected, the nail must be removed. Then the surgeon has the option of replacing it with a long, antibiotic cement-coated nail. The authors also describe temporary knee arthrodesis for infected knee arthroplasty in patients who have the potential to undergo insertion of a new implant. The procedure has two goals: eradication of infection and stabilization of the knee. A temporary knee fusion can be accomplished by inserting both an antibiotic cement-coated knee fusion nail and a static antibiotic cement-coated spacer. These advanced techniques can be helpful when treating difficult complications after knee arthrodesis and treating cases of infected knee arthroplasty. PMID:25793160
49 CFR 572.166 - Knees and knee impact test procedure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 7 2010-10-01 2010-10-01 false Knees and knee impact test procedure. 572.166... Hybrid III Six-Year-Old Weighted Child Test Dummy § 572.166 Knees and knee impact test procedure. The knee assembly is assembled and tested as specified in 49 CFR 572.126 (Subpart N). ...
Noncircular Chainrings Do Not Influence Maximum Cycling Power.
Leong, Chee-Hoi; Elmer, Steven J; Martin, James C
2017-12-01
Noncircular chainrings could increase cycling power by prolonging the powerful leg extension/flexion phases, and curtailing the low-power transition phases. We compared maximal cycling power-pedaling rate relationships, and joint-specific kinematics and powers across 3 chainring eccentricities (CON = 1.0; LOW ecc = 1.13; HIGH ecc = 1.24). Part I: Thirteen cyclists performed maximal inertial-load cycling under 3 chainring conditions. Maximum cycling power and optimal pedaling rate were determined. Part II: Ten cyclists performed maximal isokinetic cycling (120 rpm) under the same 3 chainring conditions. Pedal and joint-specific powers were determined using pedal forces and limb kinematics. Neither maximal cycling power nor optimal pedaling rate differed across chainring conditions (all p > .05). Peak ankle angular velocity for HIGH ecc was less than CON (p < .05), while knee and hip angular velocities were unaffected. Self-selected ankle joint-center trajectory was more eccentric than HIGH ecc with an opposite orientation that increased velocity during extension/flexion and reduced velocity during transitions. Joint-specific powers did not differ across chainring conditions, with a small increase in power absorbed during ankle dorsiflexion with HIGH ecc . Multiple degrees of freedom in the leg, crank, and pedal system allowed cyclists to manipulate ankle angular velocity to maintain their preferred knee and hip actions, suggesting maximizing extension/flexion and minimizing transition phases may be counterproductive for maximal power.
Self-Reported Knee Instability Before and After Total Knee Replacement Surgery.
Fleeton, Genevieve; Harmer, Alison R; Nairn, Lillias; Crosbie, Jack; March, Lyn; Crawford, Ross; van der Esch, Martin; Fransen, Marlene
2016-04-01
To determine the prevalence and burden of pain and activity limitations associated with retaining presurgery self-reported knee instability 6 months after total knee replacement (TKR) surgery and to identify early potentially modifiable risk factors for retaining knee instability in the operated knee after TKR surgery. A secondary analysis was performed using measures obtained from 390 participants undergoing primary unilateral TKR and participating in a randomized clinical trial. Self-reported knee instability was measured using 2 items from the Activities of Daily Living Scale of the Knee Outcome Survey. Outcome measures were knee pain (range 0-20) and physical function (range 0-68) on the Western Ontario and McMaster Universities Arthritis Index (WOMAC), stair-climb power, 50-foot walk time, knee range of motion, and isometric knee flexion and extension strength. In this study, 72% of participants reported knee instability just prior to surgery, with 32% retaining instability in the operated knee 6 months after surgery. Participants retaining operated knee instability had significantly more knee pain and activity limitations 6 months after surgery, with mean ± SD WOMAC scores of 4.8 ± 3.7 and 17.5 ± 11.1, respectively, compared to participants without knee instability, with 2.9 ± 3.1 and 9.8 ± 9.2. The multivariable predictor model for retained knee instability included a high comorbidity score (>6), low stair-climb power (<150 watts), more pain in the operated knee (>7 of 20), and younger age (<60 years). Self-reported knee instability is highly prevalent before and after TKR surgery and is associated with a considerable burden of pain and activity limitation in the operated knee. Increasing lower extremity muscle power may reduce the risk of retaining knee instability after TKR surgery. © 2016, American College of Rheumatology.
Smith, Matthew V; Nepple, Jeffrey J; Wright, Rick W; Matava, Matthew J; Brophy, Robert H
Football puts athletes at risk for knee injuries such meniscus and anterior cruciate ligament (ACL) tears, which are associated with the development of osteoarthritis (OA). Previous knee surgery, player position, and body mass index (BMI) may be associated with knee OA. In elite football players undergoing knee magnetic resonance imaging at the National Football League's Invitational Combine, the prevalence of knee OA is associated with previous knee surgery and BMI. Retrospective cohort. Level 4. A retrospective review was performed of all participants of the National Football League Combine from 2005 to 2009 who underwent magnetic resonance imaging of the knee because of prior knee injury, surgery, or knee-related symptoms or concerning examination findings. Imaging studies were reviewed for evidence of OA. History of previous knee surgery-including ACL reconstruction, meniscal procedures, and articular cartilage surgery-and position were recorded for each athlete. BMI was calculated based on height and weight. There was a higher prevalence of OA in knees with a history of previous knee surgery (23% vs 4.0%, P < 0.001). The prevalence of knee OA was 4.0% in those without previous knee surgery, 11% in those with a history of meniscus repair, 24% of those with a history of ACL reconstruction, and 27% of those with a history of partial meniscectomy. Among knees with a previous ACL reconstruction, the rate of OA doubled in tibiofemoral compartments in which meniscal surgery was performed. BMI >30 kg/m 2 was also associated with a higher risk of OA ( P = 0.007) but player position was not associated with knee OA. Previous knee surgery, particularly ACL reconstruction and partial meniscectomy, and elevated BMI are associated with knee OA in elite football players. Future research should investigate ways to minimize the risk of OA after knee surgery in these athletes. Treatment of knee injuries in football athletes should consider chondroprotection, including meniscal preservation and cartilage repair, when possible.
Knee Proprioception and Strength and Landing Kinematics During a Single-Leg Stop-Jump Task
Nagai, Takashi; Sell, Timothy C; House, Anthony J; Abt, John P; Lephart, Scott M
2013-01-01
Context The importance of the sensorimotor system in maintaining a stable knee joint has been recognized. As individual entities, knee-joint proprioception, landing kinematics, and knee muscles play important roles in functional joint stability. Preventing knee injuries during dynamic tasks requires accurate proprioceptive information and adequate muscular strength. Few investigators have evaluated the relationship between knee proprioception and strength and landing kinematics. Objective To examine the relationship between knee proprioception and strength and landing kinematics. Design Cross-sectional study. Setting University research laboratory. Patients or Other Participants Fifty physically active men (age = 26.4 ± 5.8 years, height = 176.5 ± 8.0 cm, mass = 79.8 ± 16.6 kg). Intervention(s) Three tests were performed. Knee conscious proprioception was evaluated via threshold to detect passive motion (TTDPM). Knee strength was evaluated with a dynamometer. A 3-dimensional biomechanical analysis of a single-legged stop-jump task was used to calculate initial contact (IC) knee-flexion angle and knee-flexion excursion. Main Outcome Measure(s) The TTDPM toward knee flexion and extension, peak knee flexion and extension torque, and IC knee-flexion angle and knee flexion excursion. Linear correlation and stepwise multiple linear regression analyses were used to evaluate the relationships of both proprioception and strength against landing kinematics. The α level was set a priori at .05. Results Enhanced TTDPM and greater knee strength were positively correlated with greater IC knee-flexion angle (r range = 0.281–0.479, P range = .001–.048). The regression analysis revealed that 27.4% of the variance in IC knee-flexion angle could be accounted for by knee-flexion peak torque and TTDPM toward flexion (P = .001). Conclusions The current research highlighted the relationship between knee proprioception and strength and landing kinematics. Individuals with enhanced proprioception and muscular strength had better control of IC knee-flexion angle during a dynamic task. PMID:23672323
Farrokhi, Shawn; Chen, Yi-Fan; Piva, Sara R.; Fitzgerald, G. Kelley; Jeong, Jong-Hyeon; Kwoh, C. Kent
2015-01-01
Objective To evaluate whether knee pain location can influence symptoms, functional status and knee-related quality of life in older adults with chronic knee pain. Methods A total of 2959 painful knees from the Osteoarthritis Initiative database were analyzed. Trained interviewers recorded patient-reported location of knee pain. Painful knees were divided into three groups of patellofemoral only pain, tibiofemoral only pain, and combined pain. Self-reported knee-specific symptoms, functional status and knee-related quality of life were assessed using the Knee Injury and Osteoarthritis Outcome Score (KOOS). Results The most common knee pain pattern was tibiofemoral only pain (62%), followed by patellofemoral only pain (23%) and combined pain (15%). The combined pain pattern was associated with greater odds of reporting pain, symptoms, sports or recreational activity limitations and lower knee-related quality of life compared to either isolated knee pain patterns, after adjusting for demographics and radiographic disease severity. Individual item analysis further revealed that patients with combined pain had greater odds of reporting difficulty with daily weightbearing activities that required knee bending compared to tibiofemoral or patellofemoral only pain patterns. Furthermore, symptoms, functional status, and knee-related quality of life were comparable between patients with patellofemoral and tibiofemoral only pain patterns, after adjusting for demographics and radiographic disease severity. Discussion Combined patellofemoral and tibiofemoral pain is associated with poorer clinical presentation compared to isolated knee pain from either location. Additionally, patellofemoral pain in isolation may be as important as tibiofemoral pain in causing symptoms and functional limitation in older adults with chronic knee pain. PMID:26308705
Arazpour, Mokhtar; Moradi, Alireza; Samadian, Mohammad; Bahramizadeh, Mahmood; Joghtaei, Mahmoud; Ahmadi Bani, Monireh; Hutchins, Stephen W; Mardani, Mohammad A
2016-06-01
Traditionally, the anatomical knee joint is locked in extension when walking with a conventional knee-ankle-foot orthosis. A powered knee-ankle-foot orthosis was developed to provide restriction of knee flexion during stance phase and active flexion and extension of the knee during swing phase of gait. The purpose of this study was to determine differences of the powered knee-ankle-foot orthosis compared to a locked knee-ankle-foot orthosis in kinematic data and temporospatial parameters during ambulation. Quasi-experimental design. Subjects with poliomyelitis (n = 7) volunteered for this study and undertook gait analysis with both the powered and the conventional knee-ankle-foot orthoses. Three trials per orthosis were collected while each subject walked along a 6-m walkway using a calibrated six-camera three-dimensional video-based motion analysis system. Walking with the powered knee-ankle-foot orthosis resulted in a significant reduction in both walking speed and step length (both 18%), but a significant increase in stance phase percentage compared to walking with the conventional knee-ankle-foot orthosis. Cadence was not significantly different between the two test conditions (p = 0.751). There was significantly higher knee flexion during swing phase and increased hip hiking when using the powered orthosis. The new powered orthosis permitted improved knee joint kinematic for knee-ankle-foot orthosis users while providing knee support in stance and active knee motion in swing in the gait cycle. Therefore, the new powered orthosis provided more natural knee flexion during swing for orthosis users compared to the locked knee-ankle-foot orthosis. This orthosis has the potential to improve knee joint kinematics and gait pattern in poliomyelitis subjects during walking activities. © The International Society for Prosthetics and Orthotics 2015.
Wang, Jianping; Tao, Kun; Li, Huanyi; Wang, Chengtao
2014-01-01
The model of three-dimensional (3D) geometric knee was built, which included femoral-tibial, patellofemoral articulations and the bone and soft tissues. Dynamic finite element (FE) model of knee was developed to simulate both the kinematics and the internal stresses during knee flexion. The biomechanical experimental system of knee was built to simulate knee squatting using cadaver knees. The flexion motion and dynamic contact characteristics of knee were analyzed, and verified by comparing with the data from in vitro experiment. The results showed that the established dynamic FE models of knee are capable of predicting kinematics and the contact stresses during flexion, and could be an efficient tool for the analysis of total knee replacement (TKR) and knee prosthesis design. PMID:25013852
Fukaya, Takashi; Mutsuzaki, Hirotaka; Okubo, Tomoyuki; Mori, Koichi; Wadano, Yasuyoshi
2016-08-01
The knee joint movement during the stance phase is affected by altered ankle movement and the center of pressure (COP). However the relationships between changes in the center of pressure (COP) and the altered kinematics and kinetics of the ankle and knee joints in patients with osteoarthritis (OA) of the knee are not well understood. The purpose of this study was to determine the relationships between changes in the COP and the altered kinematic and kinetic variables in ankle and knee joints during the stance phase in patients with medial knee OA. Fourteen patients with knee OA (21 knees) and healthy subjects were assessed by gait analysis using an eight-camera motion analysis system to record forward and lateral shifts in the COP and the angle and net internal moments of the knee and ankle joint. Spearman rank-correlation coefficients were used to determine the relationship between these results. In knees with medial OA, lateral shifts in the COP were correlated with knee flexion angle. Lateral shifts in the COP were correlated with the second peak of the knee extensor moment and correlated with the knee abductor moment. In patients with medial knee OA, lateral shifts in the COP were negatively correlated with the kinematic and kinetic variables in the sagittal plane of the knee joints. Controlling such lateral shifts in the COP may thus be an effective intervention for mechanical loads on the knee during the stance phase in patients with knee OA. Copyright © 2016 Elsevier B.V. All rights reserved.
Harding, Graeme T; Hubley-Kozey, Cheryl L; Dunbar, Michael J; Stanish, William D; Astephen Wilson, Janie L
2012-11-01
Obesity is a highly cited risk factor for knee osteoarthritis (OA), but its role in knee OA pathogenesis and progression is not as clear. Excess weight may contribute to an increased mechanical burden and altered dynamic movement and loading patterns at the knee. The objective of this study was to examine the interacting role of moderate knee OA disease presence and obesity on knee joint mechanics during gait. Gait analysis was performed on 104 asymptomatic and 140 individuals with moderate knee OA. Each subject group was divided into three body mass categories based on body mass index (BMI): healthy weight (BMI<25), overweight (25≤BMI≤30), and obese (BMI>30). Three-dimensional knee joint angles and net external knee joint moments were calculated and waveform principal component analysis (PCA) was applied to extract major patterns of variability from each. PC scores for major patterns were compared between groups using a two-factor ANOVA. Significant BMI main effects were found in the pattern of the knee adduction moment, the knee flexion moment, and the knee rotation moment during gait. Two interaction effects between moderate OA disease presence and BMI were also found that described different changes in the knee flexion moment and the knee flexion angle with increased BMI with and without knee OA. Our results suggest that increased BMI is associated with different changes in biomechanical patterns of the knee joint during gait depending on the presence of moderate knee OA. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Grigg, Josephine
2018-01-01
Background Knee osteoarthritis (OA) patients often suffer joint pain and stiffness, which contributes to negative changes in body composition, strength, physical performance (function), physical activity and health-related quality of life. To reduce these symptoms and side effects of knee OA, moderate-intensity continuous training (MICT) cycling is often recommended. While resistance training is considered the optimal form of training to improve sarcopenic outcomes, it imposes higher joint loads and requires supervision, either initially or continuously by trained exercise professionals. Therefore, this pilot study sought to gain some insight into the feasibility and potential benefits of high-intensity interval training (HIIT) cycling as an alternative exercise option to MICT cycling for individuals with knee OA. Methods Twenty-seven middle-aged and older adults with knee OA were randomly allocated to either MICT or HIIT, with both programs involving four unsupervised home-based cycling sessions (∼25 min per session) each week for eight weeks. Feasibility was assessed by enrolment rate, withdrawal rate, exercise adherence and number of adverse effects. Efficacy was assessed by health-related quality of life (Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and Lequesne index), physical function (Timed Up and Go (TUG), Sit to Stand (STS) and preferred gait speed) and body composition (body mass, BMI, body fat percentage and muscle mass). Results Twenty-seven of the interested 50 potential participants (54%) enrolled in the study, with 17 of the 27 participants completing the trial (withdrawal rate of 37%); with the primary withdrawal reasons being unrelated injuries or illness or family related issues. Of the 17 participants who completed the trial, exercise adherence was very high (HIIT 94%; MICT 88%). While only three individuals (one in the MICT and two in the HIIT group) reported adverse events, a total of 28 adverse events were reported, with 24 of these attributed to one HIIT participant. Pre–post-test analyses indicated both groups significantly improved their WOMAC scores, with the HIIT group also significantly improving in the TUG and STS. The only significant between-group difference was observed in the TUG, whereby the HIIT group improved significantly more than the MICT group. No significant changes were observed in the Lequesne index, gait speed or body composition for either group. Discussion An unsupervised home-based HIIT cycle program appears somewhat feasible for middle-aged and older adults with knee OA and may produce similar improvements in health-related quality of life but greater improvements in physical function than MICT. These results need to be confirmed in larger randomised controlled trials to better elucidate the potential for HIIT to improve outcomes for those with knee OA. Additional research needs to identify and modify the potential barriers affecting the initiation and adherence to home-based HIIT cycling exercise programs by individuals with knee OA. PMID:29761054