Fisher, Harry; Stephenson, Mitchell L; Graves, Kyle K; Hinshaw, Taylour J; Smith, Derek T; Zhu, Qin; Wilson, Margaret A; Dai, Boyi
2016-06-01
Decreased knee flexion angles during landing are associated with increased anterior cruciate ligament loading. The underlying mechanisms associated with decreased self-selected knee flexion angles during landing are still unclear. The purpose of this study was to establish the relationship between the peak force production at various knee flexion angles (35, 55, 70, and 90°) during isometric squats and the actual knee flexion angles that occur during landing in both men and women. A total of 18 men and 18 women recreational/collegiate athletes performed 4 isometric squats at various knee flexion angles while vertical ground reaction forces were recorded. Participants also performed a jump-landing-jump task while lower extremity kinematics were collected. For women, significant correlations were found between the peak force production at 55 and 70° of knee flexion during isometric squats and the knee flexion angle at initial contact of landing. There were also significant correlations between the peak force production at 55, 70, and 90° of knee flexion during isometric squats and the peak knee flexion angle during landing. These correlations tended to be stronger during isometric squats at greater knee flexion compared with smaller knee flexion. No significant correlations were found for men. Posture-specific strength may play an important role in determining self-selected knee flexion angles during landing for women.
Nakano, Naoki; Matsumoto, Tomoyuki; Muratsu, Hirotsugu; Takayama, Koji; Kuroda, Ryosuke; Kurosaka, Masahiro
2016-02-01
Although many studies have reported that postoperative knee flexion is influenced by preoperative conditions, the factors which affect postoperative knee flexion have not been fully elucidated. We tried to investigate the influence of intraoperative soft tissue balance on postoperative knee flexion angle after cruciate-retaining (CR) total knee arthroplasty (TKA) using a navigation and an offset-type tensor. We retrospectively analyzed 55 patients with osteoarthritis who underwent TKA using e.motion-CR (B. Braun Aesculap, Germany) whose knee flexion angle could be measured at 2 years after operation. The exclusion criteria included valgus deformity, severe bony defect, infection, and bilateral TKA. Intraoperative varus ligament balance and joint component gap were measured with the navigation (Orthopilot 4.2; B. Braun Aesculap) while applying 40-lb joint distraction force at 0° to 120° of knee flexion using an offset-type tensor. Correlations between the soft tissue parameters and postoperative knee flexion angle were analyzed using simple linear regression models. Varus ligament balance at 90° of flexion (R = 0.56; P < .001) and lateral compartment gap at 90° of flexion (R = 0.51; P < .001) were positively correlated with postoperative knee flexion angle. In addition, as with past studies, joint component gap at 90° of flexion (R = 0.30; P < .05) and preoperative knee flexion angle (R = 0.63; P < .001) were correlated with postoperative knee flexion angle. Lateral laxity as well as joint component gap at 90° of flexion is one of the most important factors affecting postoperative knee flexion angle in CR-TKA. Copyright © 2016 Elsevier Inc. All rights reserved.
Articular contact pressures of meniscal repair techniques at various knee flexion angles.
Flanigan, David C; Lin, Fang; Koh, Jason L; Zhang, Li-Qun
2010-07-13
Articular cartilage injury can occur after meniscal repair with biodegradable implants. Previous contact pressure analyses of the knee have been based on the tibial side of the meniscus at limited knee flexion angles. We investigated articular contact pressures on the posterior femoral condyle with different knee flexion angles and surgical repair techniques. Medial meniscus tears were repaired in 30 fresh bovine knees. Knees were mounted on a 6-degrees-of-freedom jig and statically loaded to 200 N at 45 degrees, 70 degrees, 90 degrees, and 110 degrees of knee flexion under 3 conditions: intact meniscus, torn meniscus, and meniscus after repair. For each repair, 3 sutures or biodegradable implants were used. A pressure sensor was used to determine the contact area and peak pressure. Peak pressures over each implant position were measured. Peak pressure increased significantly as knee flexion increased in normal, injured, and repaired knees. The change in peak pressure in knees with implant repairs was significantly higher than suture repairs at all knee flexion angles. Articular contact pressure on the posterior femoral condyle increased with knee flexion. Avoidance of deep knee flexion angles postoperatively may limit increases in articular contact pressures and potential chondral injury. Copyright 2010, SLACK Incorporated.
Ameer, Mariam A; Muaidi, Qassim I
2017-09-01
The relationship between knee kinematics and knee-ankle kinetics during the landing phase of single leg jumping has been widely studied to identify proper strategies for preventing non-contact ACL injury. However, there is a lack of study on knee-ankle kinetics at peak knee flexion angle during jumping from running. Hence, the purpose of this study is to establish the relationship between peak knee flexion angle, knee extension moment, ankle plantar flexion moment and ground reaction force in handball players in order to protect ACL from excessive stress during single leg jumping. In addition, the study also clarifies the role of calf muscles in relieving part of ACL stresses with different knee flexion angles during landing. Fifteen active male elite handball players of Saudi Arabia have participated in this study (Age = 22.6 ± 3.5years, Height = 182 ± 3.7 cm, Weight = 87.5 ± 10.2 kg). The players performed three successful landings of single-leg jump following running a fixed distance of about 450cm. The data were collected using a 3D motion capture and analysis system (VICON). Pearson product moment correlation coefficients showed that greater peak knee flexion angle is related significantly to both lesser knee extension moment (r = -.623, P = .013) and vertical component of ground reaction force (VGRF) (r = -.688, P = .005) in landing phase. Moreover, increasing the peak knee flexion angle in landing phase tends to increase the ankle plantar flexion moment significantly (r = .832, P = .000). With an increase of the peak knee flexion angle during single leg jump landing from running, there would be less knee extension moment, low impact force and more plantar flexion moment. As such, the clinical implication of this study is that there may be a possible protective mechanism by increasing the knee flexion angle during landing phase, which tends to protect the ACL from vigorous strain and injuries.
Tsukada, Sachiyuki; Fujii, Tomoko; Wakui, Motohiro
2017-08-01
This study was performed to assess the impact of soft tissue imbalance on the knee flexion angle 2 years after posterior stabilized total knee arthroplasty (TKA). A total of 329 consecutive varus knees were included to assess the association of knee flexion angle 2 years after TKA with preoperative, intraoperative, and postoperative variables. All intraoperative soft tissue measurements were performed by a single surgeon under spinal anesthesia in a standardized manner including the subvastus approach, reduced patella, and without use of a pneumonic tourniquet. Multiple linear regression analysis showed no significant correlations in terms of intraoperative valgus imbalance at 90-degree flexion or the difference in soft tissue tension between 90-degree flexion and 0-degree extension (β = -0.039; 95% confidence interval [CI], -0.88 to 0.80; P = .93 and β = 0.015; 95% CI, -0.29 to 0.32; P = .92, respectively). Preoperative flexion angle was significantly correlated with knee flexion angle 2 years after TKA (β = 0.42; 95% CI, 0.33 to 0.51; P < .0001). Avoiding valgus imbalance at 90-degree flexion and aiming for strictly equal soft tissue tension between 90-degree flexion and 0-degree extension had little practical value with regard to knee flexion angle 2 years after posterior stabilized TKA. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.
Knee Proprioception and Strength and Landing Kinematics During a Single-Leg Stop-Jump Task
Nagai, Takashi; Sell, Timothy C; House, Anthony J; Abt, John P; Lephart, Scott M
2013-01-01
Context The importance of the sensorimotor system in maintaining a stable knee joint has been recognized. As individual entities, knee-joint proprioception, landing kinematics, and knee muscles play important roles in functional joint stability. Preventing knee injuries during dynamic tasks requires accurate proprioceptive information and adequate muscular strength. Few investigators have evaluated the relationship between knee proprioception and strength and landing kinematics. Objective To examine the relationship between knee proprioception and strength and landing kinematics. Design Cross-sectional study. Setting University research laboratory. Patients or Other Participants Fifty physically active men (age = 26.4 ± 5.8 years, height = 176.5 ± 8.0 cm, mass = 79.8 ± 16.6 kg). Intervention(s) Three tests were performed. Knee conscious proprioception was evaluated via threshold to detect passive motion (TTDPM). Knee strength was evaluated with a dynamometer. A 3-dimensional biomechanical analysis of a single-legged stop-jump task was used to calculate initial contact (IC) knee-flexion angle and knee-flexion excursion. Main Outcome Measure(s) The TTDPM toward knee flexion and extension, peak knee flexion and extension torque, and IC knee-flexion angle and knee flexion excursion. Linear correlation and stepwise multiple linear regression analyses were used to evaluate the relationships of both proprioception and strength against landing kinematics. The α level was set a priori at .05. Results Enhanced TTDPM and greater knee strength were positively correlated with greater IC knee-flexion angle (r range = 0.281–0.479, P range = .001–.048). The regression analysis revealed that 27.4% of the variance in IC knee-flexion angle could be accounted for by knee-flexion peak torque and TTDPM toward flexion (P = .001). Conclusions The current research highlighted the relationship between knee proprioception and strength and landing kinematics. Individuals with enhanced proprioception and muscular strength had better control of IC knee-flexion angle during a dynamic task. PMID:23672323
Identification of types of landings after blocking in volleyball associated with risk of ACL injury.
Zahradnik, David; Jandacka, Daniel; Farana, Roman; Uchytil, Jaroslav; Hamill, Joseph
2017-03-01
Landing with a low knee flexion angle after volleyball block jumps may be associated with an increased risk of anterior cruciate ligament (ACL) injury. The aim of the present study was to identify the types of volleyball landings after blocks where the knee flexion angle is found to be under a critical knee flexion angle value of 30° at the instant of the first peak of the ground reaction force (GRF). Synchronized kinematic and kinetic data were collected for each trial. T-tests were used to determine if each knee flexion angle at the instant of the peak GRF was significantly different from the critical value of 30°. A repeated measures ANOVA was used to compare knee flexion angle, time to first peak and the magnitude of the first peak of the resultant GRF and knee stiffness. Significantly lower knee flexion angles were found in the "go" landing (p = .01, ES = 0.6) and the "reverse" landing (p = .02, ES = 0.6) only. The results for knee flexion angle and GRF parameters indicated a significant difference between a "reverse" and "go" and other types of landings, except the "side stick" landing for GRF. The "reverse" and "go" landings may present a risk for ACL injury due to the single-leg landing of these activities that have an associated mediolateral movement.
Shyr, Tien-Wei; Shie, Jing-Wen; Jiang, Chang-Han; Li, Jung-Jen
2014-01-01
In this work a wearable gesture sensing device consisting of a textile strain sensor, using elastic conductive webbing, was designed for monitoring the flexion angle of elbow and knee movements. The elastic conductive webbing shows a linear response of resistance to the flexion angle. The wearable gesture sensing device was calibrated and then the flexion angle-resistance equation was established using an assembled gesture sensing apparatus with a variable resistor and a protractor. The proposed device successfully monitored the flexion angle during elbow and knee movements. PMID:24577526
Fujimoto, Eisaku; Sasashige, Yoshiaki; Masuda, Yasuji; Hisatome, Takashi; Eguchi, Akio; Masuda, Tetsuo; Sawa, Mikiya; Nagata, Yoshinori
2013-12-01
The intra-operative femorotibial joint gap and ligament balance, the predictors affecting these gaps and their balances, as well as the postoperative knee flexion, were examined. These factors were assessed radiographically after a posterior cruciate-retaining total knee arthroplasty (TKA). The posterior condylar offset and posterior tibial slope have been reported as the most important intra-operative factors affecting cruciate-retaining-type TKAs. The joint gap and balance have not been investigated in assessments of the posterior condylar offset and the posterior tibial slope. The femorotibial gap and medial/lateral ligament balance were measured with an offset-type tensor. The femorotibial gaps were measured at 0°, 45°, 90° and 135° of knee flexion, and various gap changes were calculated at 0°-90° and 0°-135°. Cruciate-retaining-type arthroplasties were performed in 98 knees with varus osteoarthritis. The 0°-90° femorotibial gap change was strongly affected by the posterior condylar offset value (postoperative posterior condylar offset subtracted by the preoperative posterior condylar offset). The 0°-135° femorotibial gap change was significantly correlated with the posterior tibial slope and the 135° medial/lateral ligament balance. The postoperative flexion angle was positively correlated with the preoperative flexion angle, γ angle and the posterior tibial slope. Multiple-regression analysis demonstrated that the preoperative flexion angle, γ angle, posterior tibial slope and 90° medial/lateral ligament balance were significant independent factors for the postoperative knee flexion angle. The flexion angle change (postoperative flexion angle subtracted by the preoperative flexion angle) was also strongly correlated with the preoperative flexion angle, posterior tibial slope and 90° medial/lateral ligament balance. The postoperative flexion angle is affected by multiple factors, especially in cruciate-retaining-type TKAs. However, it is important to pay attention not only to the posterior tibial slope, but also to the flexion medial/lateral ligament balance during surgery. A cruciate-retaining-type TKA has the potential to achieve both stability and a wide range of motion and to improve the patients' activities of daily living.
Obeid, Ibrahim; Hauger, Olivier; Aunoble, Stéphane; Bourghli, Anouar; Pellet, Nicolas; Vital, Jean-Marc
2011-09-01
It has become well recognised that sagittal balance of the spine is the result of an interaction between the spine and the pelvis. Knee flexion is considered to be the last compensatory mechanism in case of sagittal imbalance, but only few studies have insisted on the relationship between spino-pelvic parameters and lower extremity parameters. Correlation between the lack of lumbar lordosis and knee flexion has not yet been established. A retrospective study was carried out on 28 patients with major spinal deformities. The EOS system was used to measure spinal and pelvic parameters and the knee flexion angle; the lack of lumbar lordosis was calculated after prediction of lumbar lordosis with two different formulas. Correlation analysis between the different measured parameters was performed. Lumbar lordosis correlated with sacral slope (r = -0.71) and moderately with knee flexion angle (r = 0.42). Pelvic tilt correlated moderately with knee flexion angle (r = 0.55). Lack of lumbar lordosis correlated best with knee flexion angle (r = 0.72 and r = 0.63 using the two formulas, respectively). Knee flexion as a compensatory mechanism to sagittal imbalance was well correlated to the lack of lordosis and, depending on the importance of the former parameter, the best procedure to correct sagittal imbalance could be chosen.
Modelling knee flexion effects on joint power absorption and adduction moment.
Nagano, Hanatsu; Tatsumi, Ichiroh; Sarashina, Eri; Sparrow, W A; Begg, Rezaul K
2015-12-01
Knee osteoarthritis is commonly associated with ageing and long-term walking. In this study the effects of flexing motions on knee kinetics during stance were simulated. Extended knees do not facilitate efficient loading. It was therefore, hypothesised that knee flexion would promote power absorption and negative work, while possibly reducing knee adduction moment. Three-dimensional (3D) position and ground reaction forces were collected from the right lower limb stance phase of one healthy young male subject. 3D position was sampled at 100 Hz using three Optotrak Certus (Northern Digital Inc.) motion analysis camera units, set up around an eight metre walkway. Force plates (AMTI) recorded ground reaction forces for inverse dynamics calculations. The Visual 3D (C-motion) 'Landmark' function was used to change knee joint positions to simulate three knee flexion angles during static standing. Effects of the flexion angles on joint kinetics during the stance phase were then modelled. The static modelling showed that each 2.7° increment in knee flexion angle produced 2.74°-2.76° increments in knee flexion during stance. Increased peak extension moment was 6.61 Nm per 2.7° of increased knee flexion. Knee flexion enhanced peak power absorption and negative work, while decreasing adduction moment. Excessive knee extension impairs quadriceps' power absorption and reduces eccentric muscle activity, potentially leading to knee osteoarthritis. A more flexed knee is accompanied by reduced adduction moment. Research is required to determine the optimum knee flexion to prevent further damage to knee-joint structures affected by osteoarthritis. Copyright © 2015 Elsevier B.V. All rights reserved.
Tang, Jing; Thorhauer, Eric; Marsh, Chelsea; Fu, Freddie H.
2013-01-01
Purpose Femoral tunnel angle (FTA) has been proposed as a metric for evaluating whether ACL reconstruction was performed anatomically. In clinic, radiographic images are typically acquired with an uncertain amount of internal/external knee rotation. The extent to which knee rotation will influence FTA measurement is unclear. Furthermore, differences in FTA measurement between the two common positions (0° and 45° knee flexion) have not been established. The purpose of this study was to investigate the influence of knee rotation on FTA measurement after ACL reconstruction. Methods Knee CT data from 16 subjects were segmented to produce 3D bone models. Central axes of tunnels were identified. The 0° and 45° flexion angles were simulated. Knee internal/external rotations were simulated in a range of ±20°. FTA was defined as the angle between the tunnel axis and femoral shaft axis, orthogonally projected into the coronal plane. Results Femoral tunnel angle was positively/negatively correlated with knee rotation angle at 0°/45° knee flexion. At 0° knee flexion, FTA for anterio-medial (AM) tunnels was significantly decreased at 20° of external knee rotation. At 45° knee flexion, more than 16° external or 19° internal rotation significantly altered FTA measurements for single-bundle tunnels; smaller rotations (±9° for AM, ±5° for PL) created significant errors in FTA measurements after double-bundle reconstruction. Conclusion Femoral tunnel angle measurements were correlated with knee rotation. Relatively small imaging malalignment introduced significant errors with knee flexed 45°. This study supports using the 0° flexion position for knee radiographs to reduce errors in FTA measurement due to knee internal/external rotation. Level of evidence Case–control study, Level III. PMID:23589127
Shi, Kenrin; Hayashida, Kenji; Umeda, Naoya; Yamamoto, Kengo; Kawai, Hideo
2008-02-01
Femoral component rollback and tibial rotation were evaluated using lateral radiographs taken during passive knee flexion under fluoroscopy in NexGen Legacy Posterior Stabilized Flex (Zimmer, Warsaw, Ind) total knee arthroplasties (TKAs; 30 with mobile insert and 26 with fixed insert). Measured maximal flexion angle demonstrated no significant differences. Femoral component rollback was observed predominantly in TKAs with fixed insert in more than 45 degrees flexion and correlated with maximal flexion angle in each group. Tibial internal rotation was more significant in TKAs with mobile insert in maximal flexion. However, tibial internal rotation from 90 degrees to maximal flexion, which demonstrated correlation with maximal flexion angle in each group, did not show significant difference. The kinematic differences between 2 inserts seemed to have little relevance to the maximal flexion angle.
Suzuki, Takashi; Motojima, Sayaka; Saito, Shu; Ishii, Takao; Ryu, Keinosuke; Ryu, Junnosuke; Tokuhashi, Yasuaki
2013-11-01
The type of osteoarthritis and the degree of severity which causes restriction of knee range of motion (ROM) is still largely unknown. The objective of this study was to analyse the location and the degree of cartilage degeneration that affect knee range of motion and the connection, if any, between femorotibial angle (FTA) and knee ROM restriction. Four hundreds and fifty-six knees in 230 subjects with knee osteoarthritis undergoing knee arthroplasty were included. Articular surface was divided into eight sections, and cartilage degeneration was evaluated macroscopically during the operation. Cartilage degeneration was classified into four grades based on the degree of exposure of subchondral bone. A Pearson correlation was conducted between FTA and knee flexion angle to determine whether high a degree of FTA caused knee flexion restriction. A logistic regression analysis was also conducted to detect the locations and levels of cartilage degeneration causing knee flexion restriction. No correlation was found between FTA and flexion angle (r = -0.08). Flexion angle was not restricted with increasing FTA. Logistic regression analysis showed significant correlation between restricted knee ROM and levels of knee cartilage degeneration in the patella (odds ratio (OR) = 1.77; P = 0.01), the lateral femoral condyle (OR = 1.62; P = 0.03) and the posterior medial femoral condyle (OR = 1.80; P = 0.03). For clinical relevance, soft tissue release and osteophyte resection around the patella, lateral femoral condyle and posterior medial femoral condyle might be indicated to obtain a higher degree of knee flexion angle.
Primary and coupled motions of the native knee in response to applied varus and valgus load.
Gladnick, Brian P; Boorman-Padgett, James; Stone, Kyle; Kent, Robert N; Cross, Michael B; Mayman, David J; Pearle, Andrew D; Imhauser, Carl W
2016-06-01
Knowledge of the complex kinematics of the native knee is a prerequisite for a successful reconstructive procedure. The aim of this study is to describe the primary and coupled motions of the native knee throughout the range of knee flexion, in response to applied varus and valgus loads. Twenty fresh-frozen cadaver knees were affixed to a six degree of freedom robotic arm with a universal force-moment sensor, and loaded with a 4Nm moment in varus and valgus at 0, 15, 30, 45, and 90° of knee flexion. The resulting tibiofemoral angulation, displacement, and rotation were recorded. For each parameter investigated, the knee joint demonstrated more laxity at higher flexion angles. Varus angulation increased progressively from zero (2.0° varus) to 90 (5.2° varus) degrees of knee flexion (p<0.001). Valgus angulation also increased progressively, from zero (1.5° valgus) to 90 (3.9° valgus) degrees of knee flexion (p<0.001). At all flexion angles, the magnitude of tibiofemoral angle deviation was larger with varus than with valgus loading (p<0.05). We conclude that the native knee exhibits small increases in coronal plane laxity as the flexion angle increases, and that the knee has generally more laxity under varus load than with valgus load throughout the Range of Motion (ROM). Larger differences in laxity of more than 2 to 3°, or peak laxity specifically during the range of mid-flexion, were not found in our cadaver model and are not likely to represent normal coronal plane kinematics. Level V, biomechanical cadaveric study. Copyright © 2016 Elsevier B.V. All rights reserved.
Kim, Hee-June; Lee, Hyun-Joo; Shin, Ji-Yeon; Choi, Young-Seo; Kyung, Hee-Soo
2017-12-01
This study evaluated the efficacy of a smartphone application in the measurement of rotation angles in porcine knees. Two K-wires were fixated to the femoral condyle and anterior tibial crest of 10 porcine legs. The angle created between the K-wires with an external rotation force applied was measured on a photograph and defined as the true angle. The same force was applied to the legs placed on a splint with a smartphone attached to the plantar side. The angle presented on a smartphone application was determined as the measured angle. The differences between the true and measured angles in 30° and 90° knee flexion and differences in measured angles depending on the status of the popliteus tendon were compared. In the intact knees, the mean true angles in 30° and 90° flexion were 20.5°±1.4° and 19.1°±1.3°, respectively, and the mean measured angles in 30° and 90° flexion were 21.1°±0.9° and 18.6°±1.6°, respectively. When the popliteus tendon was cut, the mean true angles in 30° and 90° flexion were 31.4°±1.1° and 38.5°±2.5°, respectively, and the mean measured angles in 30° and 90° flexion were 31.8°±1.2° and 39.2°±2.8°, respectively. The differences between the true and measured angles were not significant. The measured angle increased by more than 10° after cutting of the popliteus tendon in both 30° and 90° flexion. Using a smartphone application could be a good method of measuring knee rotation.
Kim, Juseung; Park, Minchul
2016-09-01
[Purpose] This study compared abdominal and hip extensor muscle activity during a bridge exercise with various knee joint angles. [Subjects and Methods] Twenty-two healthy male subjects performed a bridge exercise in which the knee joint angle was altered. While subjects performed the bridge exercise, external oblique, internal oblique, gluteus maximus, and semitendinosus muscle activity was measured using electromyography. [Results] The bilateral external and internal oblique muscle activity was significantly higher at 0° knee flexion compared to 120°, 90°, and 60°. The bilateral gluteus maximus muscle activity was significantly different at 0° of knee flexion compared to 120°, 90°, and 60°. The ipsilateral semitendinosus muscle activity was significantly increased at 90° and 60° of knee flexion compared to 120°, and significantly decreased at 0° knee flexion compared with 120°, 90°, and 60°. The contralateral semitendinosus muscle activity was significantly higher at 60° of knee flexion than at 120°, and significantly higher at 0° of knee flexion than at 120°, 90°, and 60°. [Conclusion] Bridge exercises performed with knee flexion less than 90° may be used to train the ipsilateral semitendinosus. Furthermore, bridge exercise performed with one leg may be used to train abdominal and hip extensor muscles.
The influence of muscles on knee flexion during the swing phase of gait.
Piazza, S J; Delp, S L
1996-06-01
Although the movement of the leg during swing phase is often compared to the unforced motion of a compound pendulum, the muscles of the leg are active during swing and presumably influence its motion. To examine the roles of muscles in determining swing phase knee flexion, we developed a muscle-actuated forward dynamic simulation of the swing phase of normal gait. Joint angles and angular velocities at toe-off were derived from experimental measurements, as were pelvis motions and muscle excitations. Joint angles and joint moments resulting from the simulation corresponded to experimental measurements made during normal gait. Muscular joint moments and initial joint angular velocities were altered to determine the effects of each upon peak knee flexion in swing phase. As expected, the simulation demonstrated that either increasing knee extension moment or decreasing toe-off knee flexion velocity decreased peak knee flexion. Decreasing hip flexion moment or increasing toe-off hip flexion velocity also caused substantial decreases in peak knee flexion. The rectus femoris muscle played an important role in regulating knee flexion; removal of the rectus femoris actuator from the model resulted in hyperflexion of the knee, whereas an increase in the excitation input to the rectus femoris actuator reduced knee flexion. These findings confirm that reduced knee flexion during the swing phase (stiff-knee gait) may be caused by overactivity of the rectus femoris. The simulations also suggest that weakened hip flexors and stance phase factors that determine the angular velocities of the knee and hip at toe-off may be responsible for decreased knee flexion during swing phase.
Walker, Peter S; Yildirim, Gokce; Sussman-Fort, Jon; Roth, Jonathan; White, Brian; Klein, Gregg R
2007-08-01
Maximum flexion-or impingement angle-is defined as the angle of flexion when the posterior femoral cortex impacts the posterior edge of the tibial insert. We examined the effects of femoral component placement on the femur, the slope angle of the tibial component, the location of the femoral-tibial contact point, and the amount of internal or external rotation. Posterior and proximal femoral placement, a more posterior femoral-tibial contact point, and a more tibial slope all increased maximum flexion, whereas rotation reduced it. A mobile-bearing knee gave results similar to those of the fixed-bearing knee, but there was no loss of flexion in internal or external rotation if the mobile bearing moved with the femur. In the absence of negative factors, a flexion angle of 150 degrees can be reached before impingement.
Alavekios, Damon; Peterson, Alexander; Patton, John; McGarry, Michelle H; Lee, Thay Q
2014-11-01
The purpose of this study was to compare the anterior cruciate ligament (ACL) femoral tunnel characteristics between 2 common arthroscopic portals used for ACL reconstruction, a standard anteromedial portal and a far anteromedial portal. Seven cadaveric knees were used. A 1.25-mm Kirschner wire was drilled through the center of the ACL femoral footprint and through the distal femur from the standard anteromedial and far anteromedial portals at knee flexion angles of 100°, 120°, and 140°. No formal tunnels were drilled. Each tunnel exit point was marked with a colored pin. After all tunnels were created, the specimens were digitized with a MicroScribe device (Revware, Raleigh, NC) to measure the tunnel length; distance to the posterior femoral cortical wall (posterior cortical margin); and tunnel orientation in the sagittal, coronal, and axial planes. The standard anteromedial portal resulted in a longer tunnel length, a less horizontal tunnel in the coronal plane, and a greater posterior cortical margin compared with the far anteromedial portal at all knee flexion angles. For both portal locations, the tunnel length and posterior cortical margin increased, and the tunnel position became more horizontal in the coronal plane, more anterior in the sagittal plane, and less horizontal in the transverse plane as knee flexion increased. Portal position affects femoral tunnel characteristics, with results favoring the more laterally positioned standard anteromedial portal at all flexion angles. Increasing the knee flexion angle leads to a longer femoral tunnel length and posterior femoral cortical margin with either portal position. Understanding how portal positioning and knee flexion angle affect femoral tunnel orientation and characteristics may lead to improved surgical outcomes after ACL reconstruction. Published by Elsevier Inc.
Femoral articular geometry and patellofemoral stability.
Iranpour, Farhad; Merican, Azhar M; Teo, Seow Hui; Cobb, Justin P; Amis, Andrew A
2017-06-01
Patellofemoral instability is a major cause of anterior knee pain. The aim of this study was to examine how the medial and lateral stability of the patellofemoral joint in the normal knee changes with knee flexion and measure its relationship to differences in femoral trochlear geometry. Twelve fresh-frozen cadaveric knees were used. Five components of the quadriceps and the iliotibial band were loaded physiologically with 175N and 30N, respectively. The force required to displace the patella 10mm laterally and medially at 0°, 20°, 30°, 60° and 90° knee flexion was measured. Patellofemoral contact points at these knee flexion angles were marked. The trochlea cartilage geometry at these flexion angles was visualized by Computed Tomography imaging of the femora in air with no overlying tissue. The sulcus, medial and lateral facet angles were measured. The facet angles were measured relative to the posterior condylar datum. The lateral facet slope decreased progressively with flexion from 23°±3° (mean±S.D.) at 0° to 17±5° at 90°. While the medial facet angle increased progressively from 8°±8° to 36°±9° between 0° and 90°. Patellar lateral stability varied from 96±22N at 0°, to 77±23N at 20°, then to 101±27N at 90° knee flexion. Medial stability varied from 74±20N at 0° to 170±21N at 90°. There were significant correlations between the sulcus angle and the medial facet angle with medial stability (r=0.78, p<0.0001). These results provide objective evidence relating the changes of femoral profile geometry with knee flexion to patellofemoral stability. Copyright © 2017 Elsevier B.V. All rights reserved.
Nawasreh, Zakariya; Failla, Mathew; Marmon, Adam; Logerstedt, David; Snyder-Mackler, Lynn
2018-05-23
Performing physical activities on a compliant surface alters joint kinematics and increases joints stiffness. However, the effect of compliant surface on joint kinematics after ACL-rupture is yet unknown. To compare the effects of mechanical perturbation training with a compliant surface to manual perturbation training on joint kinematics after ACL-rupture. Sixteen level I/II athletes with ACL-rupture participated in this preliminary study. Eight patients received mechanical perturbation with compliant surface (Mechanical) and 8 patients received manual perturbation training (Manual). Patients completed standard gait analysis before (Pre) and after (Post) training. Significant group-by-time interactions were found for knee flexion angle at initial contact (IC) and peak knee flexion (PKF) (p<0.004), with manual group significantly increased knee flexion angle at IC and PKF (p<0.03). Main effects of group were found for hip flexion angle at IC (Manual:34.34+3.51°, Mechanical:27.68+4.08°, p = 0.011), hip rotation angle at PKE (Manual:-3.40+4.78°, Mechanical:5.43+4.78°, p < 0.0001), and knee adduction angle at PKE (Manual:-2.00+2.23°, Mechanical:0.55+2.23°, p = 0.039). Main effects of time were found for hip adduction angle at PKE (Pre:6.98+4.48°, Post:8.41+4.91°, p = 0.04), knee adduction angle at IC (Pre:-2.90+3.50°, Post:-0.62+2.58°, p = 0.03), ankle adduction angle at IC (Pre:2.16+3.54, Post:3.8+3.68, p = 0.008), and ankle flexion angle at PKF (Pre:-4.55+2.77°, Post:-2.39+3.48°, p = 0.01). Training on a compliant surface induces different effects on joint kinematics compared to manual perturbation training after ACL-rupture. Manual perturbation improved hip alignment and increased knee flexion angles, while mechanical training decreased knee flexion angles throughout the stance phase. Administering training on a compliant surface after ACL-rupture may help improving dynamic knee stability, however, long-term effects on knee health needs to be determined. Copyright © 2018 Elsevier B.V. All rights reserved.
An Investigation into the Relation between the Technique of Movement and Overload in Step Aerobics
Wysocka, Katarzyna
2017-01-01
The aim of this research was to determine the features of a step workout technique which may be related to motor system overloading in step aerobics. Subjects participating in the research were instructors (n = 15) and students (n = 15) without any prior experience in step aerobics. Kinematic and kinetic data was collected with the use of the BTS SMART system comprised of 6 calibrated video cameras and two Kistler force plates. The subjects' task was to perform basic steps. The following variables were analyzed: vertical, anteroposterior, and mediolateral ground reaction forces; foot flexion and abduction and adduction angles; knee joint flexion angle; and trunk flexion angle in the sagittal plane. The angle of a foot adduction recorded for the instructors was significantly smaller than that of the students. The knee joint angle while stepping up was significantly higher for the instructors compared to that for the students. Our research confirmed that foot dorsal flexion and adduction performed while stepping up increased load on the ankle joint. Both small and large angles of knee flexion while stepping up and down resulted in knee joint injuries. A small trunk flexion angle in the entire cycle of step workout shut down dorsal muscles, which stopped suppressing the load put on the spine. PMID:28348501
Leppänen, Mari; Pasanen, Kati; Kujala, Urho M; Vasankari, Tommi; Kannus, Pekka; Äyrämö, Sami; Krosshaug, Tron; Bahr, Roald; Avela, Janne; Perttunen, Jarmo; Parkkari, Jari
2017-02-01
Few prospective studies have investigated the biomechanical risk factors of anterior cruciate ligament (ACL) injury. To investigate the relationship between biomechanical characteristics of vertical drop jump (VDJ) performance and the risk of ACL injury in young female basketball and floorball players. Cohort study; Level of evidence, 3. At baseline, a total of 171 female basketball and floorball players (age range, 12-21 years) participated in a VDJ test using 3-dimensional motion analysis. The following biomechanical variables were analyzed: (1) knee valgus angle at initial contact (IC), (2) peak knee abduction moment, (3) knee flexion angle at IC, (4) peak knee flexion angle, (5) peak vertical ground-reaction force (vGRF), and (6) medial knee displacement. All new ACL injuries, as well as match and training exposure, were then recorded for 1 to 3 years. Cox regression models were used to calculate hazard ratios (HRs) and 95% CIs. Fifteen new ACL injuries occurred during the study period (0.2 injuries/1000 player-hours). Of the 6 factors considered, lower peak knee flexion angle (HR for each 10° increase in knee flexion angle, 0.55; 95% CI, 0.34-0.88) and higher peak vGRF (HR for each 100-N increase in vGRF, 1.26; 95% CI, 1.09-1.45) were the only factors associated with increased risk of ACL injury. A receiver operating characteristic (ROC) curve analysis showed an area under the curve of 0.6 for peak knee flexion and 0.7 for vGRF, indicating a failed-to-fair combined sensitivity and specificity of the test. Stiff landings, with less knee flexion and greater vGRF, in a VDJ test were associated with increased risk of ACL injury among young female basketball and floorball players. However, although 2 factors (decreased peak knee flexion and increased vGRF) had significant associations with ACL injury risk, the ROC curve analyses revealed that these variables cannot be used for screening of athletes.
The biomechanical effect of increased valgus on total knee arthroplasty: a cadaveric study.
Bryant, Brandon J; Tilan, Justin U; McGarry, Michelle H; Takenaka, Nobuyuki; Kim, William C; Lee, Thay Q
2014-04-01
The effects of valgus load on cadaveric knees following total knee arthroplasty (TKA) were investigated using a custom testing system. TKAs were performed on 8 cadaveric knees and tested at 0°, 30°, and 60° knee flexion in both neutral and 5° valgus. Fuji pressure sensitive film was used to quantify contact areas and pressures and MCL strain was determined using a Microscribe digitizing system. Lateral tibiofemoral pressures increased (P < 0.05) at all knee flexion angles with valgus loading. Patellofemoral contact characteristics did not change significantly (P > 0.05). Significant increases in strain were observed along the anterior and posterior border of the MCL at all knee flexion angles. These findings suggest that valgus loading increases TKA joint contact pressures and MCL strain with increasing knee flexion which may increase implant instability. © 2014.
Assessment of tibial rotation and meniscal movement using kinematic magnetic resonance imaging
2014-01-01
Objective This work aimed to assess tibial rotations, meniscal movements, and morphological changes during knee flexion and extension using kinematic magnetic resonance imaging (MRI). Methods Thirty volunteers with healthy knees were examined using kinematic MRI. The knees were imaged in the transverse plane with flexion and extension angles from 0° to 40° and 40° to 0°, respectively. The tibial interior and exterior rotation angles were measured, and the meniscal movement range, height change, and side movements were detected. Results The tibia rotated internally (11.55° ± 3.20°) during knee flexion and rotated externally (11.40° ± 3.0°) during knee extension. No significant differences were observed between the internal and external tibial rotation angles (P > 0.05), between males and females (P > 0.05), or between the left and right knee joints (P > 0.05). The tibial rotation angle with a flexion angle of 0° to 24° differed significantly from that with a flexion angle of 24° to 40° (P < 0.01). With knee flexion, the medial and lateral menisci moved backward and the height of the meniscus increased. The movement range was greater in the anterior horn than in the posterior horn and greater in the lateral meniscus than in the medial meniscus (P < 0.01). During backward movements of the menisci, the distance between the anterior and posterior horns decreased, with the decrease more apparent in the lateral meniscus (P < 0.01). The side movements of the medial and lateral menisci were not obvious, and a smaller movement range was found than that of the forward and backward movements. Conclusion Knee flexion and extension facilitated internal and external tibial rotations, which may be related to the ligament and joint capsule structure and femoral condyle geometry. PMID:25142267
Schreurs, Mervin J; Benjaminse, Anne; Lemmink, Koen A P M
2017-10-03
Cutting is an important skill in team-sports, but unfortunately is also related to non-contact ACL injuries. The purpose was to examine knee kinetics and kinematics at different cutting angles. 13 males and 16 females performed cuts at different angles (45°, 90°, 135° and 180°) at maximum speed. 3D kinematics and kinetics were collected. To determine differences across cutting angles (45°, 90°, 135° and 180°) and sex (female, male), a 4×2 repeated measures ANOVA was conducted followed by post hoc comparisons (Bonferroni) with alpha level set at α≤0.05a priori. At all cutting angles, males showed greater knee flexion angles than females (p<0.01). Also, where males performed all cutting angles with no differences in the amount of knee flexion -42.53°±8.95°, females decreased their knee flexion angle from -40.6°±7.2° when cutting at 45° to -36.81°±9.10° when cutting at 90°, 135° and 180° (p<0.01). Knee flexion moment decreased for both sexes when cutting towards sharper angles (p<0.05). At 90°, 135° and 180°, males showed greater knee valgus moments than females. For both sexes, knee valgus moment increased towards the sharper cutting angles and then stabilized compared to the 45° cutting angle (p<0.01). Both females and males showed smaller vGRF when cutting to sharper angles (p<0.01). It can be concluded that different cutting angles demand different knee kinematics and kinetics. Sharper cutting angles place the knee more at risk. However, females and males handle this differently, which has implications for injury prevention. Copyright © 2017 Elsevier Ltd. All rights reserved.
Analysis of Balance Ability Dependent on the Angle of the Knee Joint in Females in Their 20s
Yoon, Se-Won; Lee, Jeong-Woo; Cho, Woon-Su; Kim, An-Na; Lee, Kyung-Hee
2013-01-01
The aim of this study was to investigate how balance ability according to angle of the knee joint changes in young female adults wearing a knee orthosis. [Methods] This study was conducted with 11 healthy female adults. The subjects used a knee brace that could be set to angles of 0°, 15°, and 30° of knee flexion. The ability to balance was evaluated by balance assessment. A total of four postures were used for measurements: a forward-facing posture with the eyes open on a stable surface (NO), a forward-facing posture with the eyes closed on a stable surface (NC), a forward-facing posture with the eyes open on an unstable surface (PO), and a forward-facing posture with the eyes closed on an unstable surface (PC). [Results] Regarding the weight distribution index and stability index on a stable surface, there was no interaction according to whether there was visual deprivation or not or according to knee flexion angle. Furthermore, the stability index on an unstable surface showed no interaction according to whether there was visual deprivation or not or according to knee flexion angle. But the WDI on a stable surface showed no interaction according to whether there was visual deprivation or not or according to knee flexion angle. [Conclusion] There were significant differences in the knee extension range of motion of normal elderly people and knee osteoarthritis, and the quadriceps femoris played an important role in knee function in individuals with knee osteoarthritis. PMID:24259902
Yang, Zhaochun; Wickwire, Alexis C; Debski, Richard E
2010-11-01
Recent clinical evidence has suggested that tasks performed in kneeling or squatting postures place the knee at a higher risk for injury because loads across the knee might overload the ligaments. The objective of this study was to develop a subject-specific model of the knee that is kinematically driven to predict the forces in the major ligaments at high flexion angles. The geometry of the femur, tibia, and fibula and the load-elongation curves representing the structural properties of the ACL, PCL, LCL, and MCL served as inputs to the model, which represented each ligament as a nonlinear elastic spring. To drive the model, kinematic data was obtained while loads were applied to the same cadaveric knee at four flexion angles. The force in each ligament during the recorded kinematic data allowed an optimization procedure to determine the location of the ligament attachment sites on each bone and their reference lengths. The optimization procedure could successfully minimize the differences between the experimental and predicted forces only when the kinematics at 90°, 120°, and 140° of flexion were utilized. This finding suggests that the ligaments at the knee function differently at high-flexion angles compared to low flexion angles and separate models must be used to examine each range of motion. In the future, the novel experimental and computational methodology will be used to construct additional models and additional knee kinematics will be input to help elucidate mechanisms of injury during tasks performed in kneeling or squatting postures.
Wada, Keizo; Hamada, Daisuke; Tamaki, Shunsuke; Higashino, Kosaku; Fukui, Yoshihiro; Sairyo, Koichi
2017-01-01
Previous studies suggested that changes in kinematics in total knee arthroplasty (TKA) affected satisfaction level. The aim of this cadaveric study was to evaluate the effect of medial collateral ligament (MCL) release by multiple needle puncture on knee rotational kinematics in posterior-stabilized TKA. Six fresh, frozen cadaveric knees were included in this study. All TKA procedures were performed with an image-free navigation system using a 10-mm polyethylene insert. Tibial internal rotation was assessed to evaluate intraoperative knee kinematics. Multiple needle puncturing was performed 5, 10, and 15 times for the hard portion of the MCL at 90° knee flexion. Kinematic analysis was performed after every 5 punctures. After performing 15 punctures, a 14-mm polyethylene insert was inserted, and kinematic analysis was performed. The tibial internal rotation angle at maximum knee flexion without multiple needle puncturing was significantly larger (9.42°) than that after 15 punctures (3°). Negative correlation (Pearson r = -0.715, P < .001) between tibial internal rotation angle at maximum knee flexion and frequency of puncture was observed. The tibial internal rotation angle with a 14-mm insert was significantly larger (7.25°) compared with the angle after 15 punctures. Tibial internal rotation during knee flexion was reduced by extensive MCL release using multiple needle puncturing and was recovered by increasing of medial tightness. From the point of view of knee kinematics, medial tightness should be allowed to maintain the internal rotation angle of the tibia during knee flexion which might lead to patient satisfaction. Copyright © 2016 Elsevier Inc. All rights reserved.
Choi, Chong Hyuk; Kim, Sung-Jae; Chun, Yong-Min; Kim, Sung-Hwan; Lee, Su-Keon; Eom, Nam-Kyu; Jung, Min
2018-01-01
The purpose of this study was to find appropriate flexion angle and transverse drill angle for optimal femoral tunnels of anteromedial (AM) bundle and posterolateral (PL) bundle in double-bundle ACL reconstruction using transportal technique. Thirty three-dimensional knee models were reconstructed. Knee flexion angles were altered from 100° to 130° at intervals of 10°. Maximum transverse drill angle (MTA), MTA minus 10° and 20° were set up. Twelve different tunnels were determined by four flexion angles and three transverse drill angles for each bundle. Tunnel length, wall breakage, inter-tunnel communication and graft-bending angle were assessed. Mean tunnel length of AM bundle was >30mm at 120° and 130° of flexion in all transverse drill angles. Mean tunnel length of PL bundle was >30mm during every condition. There were ≥1 cases of wall breakage except at 120° and 130° of flexion with MTA for AM bundle. There was no case of wall breakage for PL bundle. Considering inter-tunnel gap of >2mm without communication and obtuse graft-bending angle, 120° of flexion and MTA could be recommended as optimal condition for femoral tunnels of AM and PL bundles. Flexion angle and transverse drill angle had combined effect on femoral tunnel in double-bundle ACL reconstruction using transportal technique. Achieving flexion angle of 120° and transverse drill angle close to the medial femoral condyle could be recommended as optimal condition for femoral tunnels of AM and PL bundles to avoid insufficient tunnel length, wall breakage, inter-tunnel communication and acute graft-bending angle. Copyright © 2017 Elsevier B.V. All rights reserved.
Herrington, Lee; Bendix, Katie; Cornwell, Catherine; Fielden, Nicola; Hankey, Karen
2008-08-01
The purpose of the study was to assess the effect of structural differentiation or sensitising manoeuvres on responses of normal subjects to standard neurodynamic tests of straight leg raise (SLR) and slump test. Eighty-eight (39 males and 49 females) asymptomatic subjects were examined (aged 18-39 mean age 21.9+/-4.1 years). Knee flexion angle was measured using a goniometer during the slump test in two conditions cervical flexion and extension. Hip flexion angle was measured using a goniometer during SLR test in two conditions; ankle dorsi-flexion and neutral. The change in knee flexion, following addition of the structural differentiating manoeuvre to the slump test, was a significant increase in knee flexion angle for both males (change in knee angle; 6.6+/-4.7 degrees /18.7+/-17.5%, p<0.01) and females (change in knee angle 5.4+/-5.8 degrees /17.6+/-23.7%, p<0.01), though showed no difference between sides (p>0.05). During the SLR test, a significant reduction in hip flexion occurred following structural differentiation for both groups (change in hip angle; males = 9.5+/-8.3 degrees /21.5+/-18.8%, p<0.01; females = 15.2+/-9.5 degrees /25.9+/-13.9%, p<0.01), though showed no difference between sides (p>0.05). Structural differentiating manoeuvres have a significant effect on test response in terms of range of movement even in normal asymptomatic individuals. These responses should be taken into account during the assessment clinical reasoning process.
Squat exercise to estimate knee megaprosthesis rehabilitation: a pilot study
Lovecchio, Nicola; Zago, Matteo; Sciumè, Luciana; Lopresti, Maurizio; Sforza, Chiarella
2015-01-01
[Purpose] This study evaluated a specific rehabilitation protocol using a half squat after total knee reconstruction with distal femur megaprosthesis and tibial allograft-prosthesis composite. [Subject and Methods] Squat execution was recorded by a three-dimensional system before and after a specific rehabilitation program on a 28-year-old patient. Squat duration, body center of mass trajectory, and vertical range of motion were determined. Step width and joint angles and symmetry (hip flexion, extension, and rotation, knee flexion, and ankle dorsal and plantar flexion) were estimated. Knee and hip joint symmetry was computed using a bilateral cyclogram technique. [Results] After rehabilitation, the squat duration was longer (75%), step width was similar, and vertical displacement was higher. Hip flexion increased by over 20%, and ankle dorsiflexion diminished by 14%. The knee had the highest symmetry gain (4.1–3.4%). Angle-angle plot subtended areas decreased from 108° to 40°2 (hip) and from 204° to 85°2 (knee), showing improvement in movement symmetry. [Conclusion] We concluded that the squat is an effective multifactorial exercise to estimate rehabilitation outcomes after megaprosthesis, also considering that compressive and shear forces are minimal up to 60–70° of knee flexion. PMID:26311992
A Study of Knee Joint Kinematics and Mechanics using a Human FE Model.
Kitagawa, Yuichi; Hasegawa, Junji; Yasuki, Tsuyoshi; Iwamoto, Masami; Miki, Kazuo
2005-11-01
Posterior translation of the tibia with respect to the femur can stretch the posterior cruciate ligament (PCL). Fifteen millimeters of relative displacement between the femur and tibia is known as the Injury Assessment Reference Value (IARV) for the PCL injury. Since the anterior protuberance of the tibial plateau can be the first site of contact when the knee is flexed, the knee bolster is generally designed with an inclined surface so as not to directly load the projection in frontal crashes. It should be noted, however, that the initial flexion angle of the occupant knee can vary among individuals and the knee flexion angle can change due to the occupant motion. The behavior of the tibial protuberance related to the knee flexion angle has not been described yet. The instantaneous angle of the knee joint at the timing of restraining the knee should be known to manage the geometry and functions of knee restraint devices. The purposes of this study are first to understand the kinematics of the knee joint during flexion, and second to characterize the mechanics of the knee joint under anterior-posterior loading. A finite element model of the knee joint, extracted from the Total Human Model for Safety (THUMS), was used to analyze the mechanism. The model was validated against kinematics and mechanical responses of the human knee joint. By tracking the relative positions and angles between the patella and the tibia in a knee flexing simulation, the magnitude of the tibial anterior protuberance was described as a function of the knee joint angle. The model revealed that the mechanics of the knee joint was characterized as a combination of stiffness of the patella-femur structure and the PCL It was also found that the magnitude of the tibial anterior protuberance determined the amount of initial stretch of the PCL in anterior-posterior loading. Based on the knee joint kinematics and mechanics, an interference boundary was proposed for different knee flexion angles, so as not to directly load the anterior protuberance of the tibial plateau in restraining of the knee. A frontal crash simulation was performed using a partial vehicle model with the THUMS seated. The performance and effects of the knee airbag, as one of the candidates for knee restraint devices, were evaluated through the simulation.
Ali, Nicholas; Rouhi, Gholamreza; Robertson, Gordon
2013-01-01
There is a lack of studies investigating gender differences in whole-body kinematics during single-leg landings from increasing vertical heights and horizontal distances. This study determined the main effects and interactions of gender, vertical height, and horizontal distance on whole-body joint kinematics during single-leg landings, and established whether these findings could explain the gender disparity in non-contact anterior cruciate ligament (ACL) injury rate. Recreationally active males (n=6) and females (n=6) performed single-leg landings from a takeoff deck of vertical height of 20, 40, and 60 cm placed at a horizontal distance of 30, 50 and 70 cm from the edge of a force platform, while 3D kinematics and kinetics were simultaneously measured. It was determined that peak vertical ground reaction force (VGRF) and the ankle flexion angle exhibited significant gender differences (p=0.028, partial η(2)=0.40 and p=0.035, partial η(2)=0.37, respectively). Peak VGRF was significantly correlated to the ankle flexion angle (r= -0.59, p=0.04), hip flexion angle (r= -0.74, p=0.006), and trunk flexion angle (r= -0.59, p=0.045). Peak posterior ground reaction force (PGRF) was significantly correlated to the ankle flexion angle (r= -0.56, p=0.035), while peak knee abduction moment was significantly correlated to the knee flexion angle (r= -0.64, p=0.03). Rearfoot landings may explain the higher ACL injury rate among females. Higher plantar-flexed ankle, hip, and trunk flexion angles were associated with lower peak ground reaction forces, while higher knee flexion angle was associated with lower peak knee abduction moment, and these kinematics implicate reduced risk of non-contact ACL injury.
A Highly Backdrivable, Lightweight Knee Actuator for Investigating Gait in Stroke
Sulzer, James S.; Roiz, Ronald A.; Peshkin, Michael A.; Patton, James L.
2012-01-01
Many of those who survive a stroke develop a gait disability known as stiff-knee gait (SKG). Characterized by reduced knee flexion angle during swing, people with SKG walk with poor energy efficiency and asymmetry due to the compensatory mechanisms required to clear the foot. Previous modeling studies have shown that knee flexion activity directly before the foot leaves the ground, and this should result in improved knee flexion angle during swing. The goal of this research is to physically test this hypothesis using robotic intervention. We developed a device that is capable of assisting knee flexion torque before swing but feels imperceptible (transparent) for the rest of the gait cycle. This device uses sheathed Bowden cable to control the deflection of a compliant torsional spring in a configuration known as a Series Elastic Remote Knee Actuator (SERKA). In this investigation, we describe the design and evaluation of SERKA, which includes a pilot experiment on stroke subjects. SERKA could supply a substantial torque (12 N· m) in less than 20 ms, with a maximum torque of 41 N·m. The device resisted knee flexion imperceptibly when desired, at less than 1 N·m rms torque during normal gait. With the remote location of the actuator, the user experiences a mass of only 1.2 kg on the knee. We found that the device was capable of increasing both peak knee flexion angle and velocity during gait in stroke subjects. Thus, the SERKA is a valid experimental device that selectively alters knee kinetics and kinematics in gait after stroke. PMID:22563305
Park, Kwan Kyu; Hosseini, Ali; Tsai, Tsung-Yuan; Kwon, Young-Min; Li, Guoan
2015-02-05
The mechanisms that affect knee flexion after total knee arthroplasty (TKA) are still debatable. This study investigated the elongation of the superficial medial (sMCL) and lateral collateral ligaments (LCL) before and after a posterior cruciate retaining (CR) TKA. We hypothesized that overstretching of the collateral ligaments in high flexion after TKA could reduce maximal flexion of the knee. Three-dimensional models of 11 osteoarthritic knees of 11 patients including the insertions of the collateral ligaments were created using MR images. Each ligament was divided into three equal portions: anterior, middle and posterior portions. The shortest 3D wrapping length of each ligament portion was determined before and after the TKA surgery along a weight-bearing, single leg flexion path. The relationship between the changes of ligament elongation and the changes of the maximal knee flexion after TKAs was quantitatively analyzed. The sMCL showed significant increases in length only at low flexion after TKA; the LCL showed decreases in length at full extension, but increases with further flexion after TKA. The amount of increases of the maximum flexion angle after TKA was negatively correlated with the increases of the elongations of the anterior portion (p=0.010, r=0.733) and middle portion (p=0.049, r=0.604) of the sMCL as well as the anterior portion (p=0.010, r=0.733) of the LCL at maximal flexion of the knee. The results indicated that the increases of the length of the collateral ligaments at maximal flexion after TKA were associated with the decreases of the maximal flexion of the knee. Our data suggest that collateral ligament management should also be evaluated at higher knee flexion angles in order to optimize maximal flexion of the knee after TKAs. Copyright © 2014 Elsevier Ltd. All rights reserved.
Debandi, Aníbal; Maeyama, Akira; Hoshino, Yuichi; Asai, Shigehiro; Goto, Bunsei; Smolinski, Patrick; Fu, Freddie H
2016-11-01
To evaluate the effect of knee flexion angle for hamstring graft fixation, full extension (FE), or 30°, on acceleration of the knee motion during pivot-shift testing after either anatomic or nonanatomic anterior cruciate ligament (ACL) reconstruction using triaxial accelerometry. Two types of ACL reconstructions (anatomic and nonanatomic) using 2 different angles of knee flexion during graft fixation (FE and 30°) were performed on 12 fresh-frozen human knees making 4 groups: anatomic-FE, anatomic-30°, nonanatomic-FE, and nonanatomic-30°. Manual pivot-shift testing was performed at ACL-intact, ACL-deficient, and ACL-reconstructed conditions. Three-dimensional acceleration of knee motion was recorded using a triaxial accelerometer. The anatomic-30° group showed the smallest overall magnitude of acceleration among the ACL-reconstructed groups (P = .0039). There were no significant differences among the anatomic-FE group, the nonanatomic-FE group, and the nonantomic-30° group (anatomic-FE vs nonanatomic-FE, P = .1093; anatomic-FE vs nonanatomic-30°, P = .8728; and nonanatomic-FE vs nonanatomic-30°, P = .1093). After ACL transection, acceleration was reduced by ACL reconstruction with the exception of the nonanatomic-FE group that did not show a significant difference when compared with the ACL-deficient (P = .4537). The anatomic ACL reconstruction with the graft fixed at 30° of knee flexion better restored rotational knee stability compared with FE. An ACL graft fixed with the knee at FE in anatomic position did not show a significant difference compared with the nonanatomic ACL reconstructions. Knee flexion angle at the time of graft fixation for ACL reconstruction can be considered to maximize the rotational knee stability. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Lorbach, Olaf; Zumbansen, Nikolaus; Kieb, Matthias; Efe, Turgay; Pizanis, Antonius; Kohn, Dieter; Haupert, Alexander
2018-04-01
Objective evaluation of the optimal graft tension angle to fully restore patellofemoral contact pressure in reconstruction of the medial patellofemoral ligament (MPFL) in comparison to the native knee. Twelve cadaveric knee specimens were fixed in a custom-made fixation device. A sensitive pressure film (Tekscan) was fixed in the patellofemoral joint, and patellofemoral contact pressure was assessed during a dynamic flexion movement from 0° to 90°. The MPFL was cut and measurements were repeated. Reconstruction of the MPFL was performed with the gracilis tendon subsequently fixed in the femur at 15°, 30°, 45°, 60°, 75°, and 90° of knee flexion under controlled tension (2 N). The sequence of the flexion angles was alternated. Pressure measurements were repeated after every fixation of the graft. No significant differences were seen in the overall patellofemoral contact pressure compared to the native knee (P > .05). However, medial patellofemoral pressure showed a significant increased patellofemoral contact pressure after MPFL reconstruction at a knee flexion angle during graft fixation of 15° (P = .027), 45° (P = .050, P = .044), and 75° (P = .039). Moreover, proximal/distal patellofemoral contact pressure revealed a significantly reduced contact pressure at 15° (P = .003), 30° (P = .009), 45° (P = .025), 75° (P = .021), and 90° (P = .022) of flexion distal after MPFL reconstruction compared with the intact knee. Lateral patellofemoral contact pressure was significantly reduced in all performed reconstructions (P < .05). The flexion angle during graft fixation for MPFL reconstruction did not have a significant impact on the overall patellofemoral contact pressure. However, selective medial, proximal, distal, and lateral patellofemoral contact pressure was significantly altered for all reconstructions. Fixation of the MPFL graft at 60° of flexion was able to most closely restore patellofemoral contact pressure compared with the intact knee. Based on the findings of the present study, fixation of the graft in anatomic reconstruction of the MPFL should be considered in 60° of flexion under low tension (2 N) to most closely restore patellofemoral contact pressure compared with the native knee. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
The role of the deep medial collateral ligament in controlling rotational stability of the knee.
Cavaignac, Etienne; Carpentier, Karel; Pailhé, Regis; Luyckx, Thomas; Bellemans, Johan
2015-10-01
The tibial insertion of the deep medial collateral ligament (dMCL) is frequently sacrificed when the proximal tibial cut is performed during total knee arthroplasty. The role of the dMCL in controlling the knee's rotational stability is still controversial. The aim of this study was to quantify the rotational laxity induced by an isolated lesion of the dMCL as it occurs during tibial preparation for knee arthroplasty. An isolated resection of the deep MCL was performed in 10 fresh-frozen cadaver knees. Rotational laxity was measured during application of a standard 5.0 N.m rotational torque. Maximal tibial rotation was measured at different knee flexion angles using an image-guided navigation system (Medivision Surgetics system, Praxim, Grenoble, France) before and after dMCL resection. In all cases, internal and external tibial rotation increased after dMCL resection. Total rotational laxity increased significantly for all knee flexion angles, with an average difference of +7.8° (SD 5.7) with the knee in extension, +8.9° (SD 1.9) in 30° flexion, +7° (SD 2.9) in 60° flexion and +5.3° (SD 2.8) in 90° flexion. Sacrificing the tibial insertion of the deep MCL increases rotational laxity of the knee by 5°-9°, depending on the knee flexion angle. Based on our findings, new surgical techniques and implants that preserve the dMCL insertion such as tibial inlay components should be developed. Further clinical evaluations are necessary.
Shi, Xiaojun; Shen, Bin; Kang, Pengde; Yang, Jing; Zhou, Zongke; Pei, Fuxing
2013-12-01
To evaluate and quantify the effect of the tibial slope on the postoperative maximal knee flexion and stability in the posterior-stabilized total knee arthroplasty (TKA). Fifty-six patients (65 knees) who had undergone TKA with the posterior-stabilized prostheses were divided into the following 3 groups according to the measured tibial slopes: Group 1: ≤4°, Group 2: 4°-7° and Group 3: >7°. The preoperative range of the motion, the change in the posterior condylar offset, the elevation of the joint line, the postoperative tibiofemoral angle and the preoperative and postoperative Hospital for Special Surgery (HSS) scores were recorded. The tibial anteroposterior translation was measured using the Kneelax 3 Arthrometer at both the 30° and the 90° flexion angles. The mean values of the postoperative maximal knee flexion were 101° (SD 5), 106° (SD 5) and 113° (SD 9) in Groups 1, 2 and 3, respectively. A significant difference was found in the postoperative maximal flexion between the 3 groups (P < 0.001). However, no significant differences were found between the 3 groups in the postoperative HSS scores, the changes in the posterior condylar offset, the elevation of the joint line or the tibial anteroposterior translation at either the 30° or the 90° flexion angles. A 1° increase in the tibial slope resulted in a 1.8° flexion increment (r = 1.8, R (2) = 0.463, P < 0.001). An increase in the posterior tibial slope can significantly increase the postoperative maximal knee flexion. The tibial slope with an appropriate flexion and extension gap balance during the operation does not affect the joint stability.
Anteroposterior translation does not correlate with knee flexion after total knee arthroplasty.
Ishii, Yoshinori; Noguchi, Hideo; Takeda, Mitsuhiro; Sato, Junko; Toyabe, Shin-ichi
2014-02-01
Stiffness after a TKA can cause patient dissatisfaction and diminished function, therefore it is important to characterize predictors of ROM after TKA. Studies of AP translation in conscious individuals disagree whether AP translation affects maximum knee flexion angle after implantation of a highly congruent sphere and trough geometry PCL-substituting prosthesis in a TKA. We investigated whether AP translation correlated with maximum knee flexion angle (1) in patients who were awake, and (2) who were under anesthesia (to minimize the effects of voluntary muscle contraction) in a TKA with implantation of a PCL-substituting mobile-bearing prosthesis. AP translation was examined under both conditions in 34 primary TKAs. Measurements under anesthesia were performed when the patients were having anesthesia for a contralateral TKA. Awake measurements were made within 4 days of that anesthetic session in patients who had no residual sedative effects. The average postoperative interval for the index TKA flexion measurements was 23 months (range, 6-114 months). AP translation was evaluated at 75° flexion using an arthrometer. There was no correlation between postoperative maximum knee flexion and AP translation at 75° during consciousness. There was no correlation between postoperative maximum knee flexion and AP translation under anesthesia. AP translation at 75° flexion did not correlate with postoperative maximum knee flexion in either awake or anesthetized patients during a TKA with implantation of a posterior cruciate-substituting prosthesis.
Laugharne, Edward; Bali, Navi; Purushothamdas, Sanjay; Almallah, Faris; Kundra, Rik
2016-01-01
Purpose The purpose of this study was to investigate the impact of varying knee flexion and quadriceps activity on patellofemoral indices measured on magnetic resonance imaging (MRI). Materials and Methods MRI of the knee was performed in 20 patients for indications other than patellar or patellofemoral pathology. Axial and sagittal sequences were performed in full extension of the knee with the quadriceps relaxed, full extension of the knee with the quadriceps contracted, 30° flexion of the knee with the quadriceps relaxed, and 30° flexion with the quadriceps contracted. Bisect offset, patella tilt angle, Insall-Salvati ratio and Caton-Deschamps index were measured. Results With the knee flexed to 30° and quadriceps relaxed, the mean values of patellar tilt angle, bisect offset, Insall-Salvati ratio and Caton-Deschamps index were all within normal limits. With the knee extended and quadriceps contracted, the mean patellar tilt angle (normal value, <15°) was 14.6° and the bisect offset (normal value, <65%) was 65%, while the Caton-Deschamps index was 1.34 (normal range, 0.6 to 1.3). With the knee extended and quadriceps relaxed, the mean Caton-Deschamps index was 1.31. Conclusions MRI scanning of the knee in extension with the quadriceps contracted leads to elevated patellofemoral indices. MRI taken with the knee in 30° of flexion allows more reliable assessment of the patellofemoral joint and minimises the confounding effect of quadriceps contraction. PMID:27894177
Mulcahey, Mary K.; Monchik, Keith O.; Yongpravat, Charlie; Badger, Gary J.; Fadale, Paul D.; Hulstyn, Michael J.; Fleming, Braden C.
2011-01-01
The purpose of this study was to compare tibiofemoral (TF) kinematics and TF compressive stresses between single bundle- (SB-) and double bundle-ACL reconstruction (DB-ACLR) during simulated squatting. Twelve matched pairs of fresh frozen cadaver knees were utilized. A simulated squat through 100° of knee flexion was performed in the ACL-intact joint. The ACL was transected and SB- and DB-ACLR procedures were performed in one knee of each pair. The squat was repeated. Knee kinematics were measured using a motion tracking system and the TF compressive forces were measured using thin film pressure sensors. The posterior shifts of the tibia for SB- and DB-ACLR knees were significantly greater than the ACL-intact condition for knee flexion angles 0° to 40° (p<.05). However, there was no difference between the SB- and DB-ACLR knees at any flexion angle (0° to 100°; p=.37). SB- and DB-ACLR knees had greater IE rotation than intact knees from 90° through 50° of flexion (p<.05), but not between 40° and full extension. There was no difference between SB- and DB-ACLR knees (p=.68). The TF compressive stresses of the DB-ACLR were significantly lower than intact for all angles except 10° (p=.06), whereas SB-ACLR knees did not differ from intact at flexion angles between 30° and 50° (p>.32). There were no significant differences between the two reconstruction conditions (p=.74). This study showed that there was no difference in the TF kinematics or compressive stresses between SB- and DB-ACLR, and only minor differences when compared to the intact state. PMID:21696962
Hino, Kazunori; Oonishi, Yoshio; Kutsuna, Tatsuhiko; Watamori, Kunihiko; Iseki, Yasutake; Kiyomatsu, Hiroshi; Watanabe, Seiji; Miura, Hiromasa
2016-08-01
Restoration of normal knee kinematics is key to improving patient satisfaction and functional outcomes after total knee arthroplasty (TKA). However, the effect of preoperative varus-valgus kinematics due to knee osteoarthritis on the postoperative kinematics is unclear. The function of the knee ligament contributes to both knee stability and kinematics. The aim of this study was to evaluate changes in varus-valgus kinematics before and after TKA using a navigation system, in addition to comparing the pre- and postoperative changes in kinematic patterns between cruciate-retaining (CR)- and posterior-stabilized (PS)-TKAs. Forty knees treated with TKA were evaluated (CR-TKA 20; PS-TKA 20). Manual mild passive knee flexion was applied while moving the leg from full extension to flexion. The varus-valgus angle was automatically measured by a navigation system at every 10° of the flexion angle, and the kinematics were evaluated. Kinematic patterns throughout flexion can be classified into five types. The pre- and postoperative kinematic patterns were similar in 60% of patients who underwent CR-TKA, whereas they were similar in only 25% of those who underwent PS-TKA. The mean change in the size of the varus-valgus angle throughout flexion did not differ between CR-TKA and PS-TKA. However, the distribution of changes in the size of the varus-valgus angle differed between CR-TKA and PS-TKA. We obtained the following results: 1) some patterns of varus-valgus kinematics are noted under unloading conditions despite recovery of neutral alignment in extension and 2) the preoperative varus-valgus kinematic pattern persisted more strongly after CR-TKA than after PS-TKA. Copyright © 2015 Elsevier B.V. All rights reserved.
Malfait, Bart; Dingenen, Bart; Smeets, Annemie; Staes, Filip; Pataky, Todd; Robinson, Mark A; Vanrenterghem, Jos; Verschueren, Sabine
2016-01-01
The purpose was to assess if variation in sagittal plane landing kinematics is associated with variation in neuromuscular activation patterns of the quadriceps-hamstrings muscle groups during drop vertical jumps (DVJ). Fifty female athletes performed three DVJ. The relationship between peak knee and hip flexion angles and the amplitude of four EMG vectors was investigated with trajectory-level canonical correlation analyses over the entire time period of the landing phase. EMG vectors consisted of the {vastus medialis(VM),vastus lateralis(VL)}, {vastus medialis(VM),hamstring medialis(HM)}, {hamstring medialis(HM),hamstring lateralis(HL)} and the {vastus lateralis(VL),hamstring lateralis(HL)}. To estimate the contribution of each individual muscle, linear regressions were also conducted using one-dimensional statistical parametric mapping. The peak knee flexion angle was significantly positively associated with the amplitudes of the {VM,HM} and {HM,HL} during the preparatory and initial contact phase and with the {VL,HL} vector during the peak loading phase (p<0.05). Small peak knee flexion angles were significantly associated with higher HM amplitudes during the preparatory and initial contact phase (p<0.001). The amplitudes of the {VM,VL} and {VL,HL} were significantly positively associated with the peak hip flexion angle during the peak loading phase (p<0.05). Small peak hip flexion angles were significantly associated with higher VL amplitudes during the peak loading phase (p = 0.001). Higher external knee abduction and flexion moments were found in participants landing with less flexed knee and hip joints (p<0.001). This study demonstrated clear associations between neuromuscular activation patterns and landing kinematics in the sagittal plane during specific parts of the landing. These findings have indicated that an erect landing pattern, characterized by less hip and knee flexion, was significantly associated with an increased medial and posterior neuromuscular activation (dominant hamstrings medialis activity) during the preparatory and initial contact phase and an increased lateral neuromuscular activation (dominant vastus lateralis activity) during the peak loading phase.
Cho, Misuk
2015-06-01
[Purpose] This study aimed to identify correlations among pelvic positions and differences in lower extremity joint angles during walking in female university students. [Subjects] Thirty female university students were enrolled and their pelvic positions and differences in lower extremity joint angles were measured. [Methods] Pelvic position, pelvic torsion, and pelvic rotation were assessed using the BackMapper. In addition, motion analysis was performed to derive differences between left and right flexion, abduction, and external rotation ranges of hip joints; flexion, abduction, and external rotation ranges of knee joints; and dorsiflexion, inversion, and abduction ranges of ankle joints, according to X, Y, and Z-axes. [Results] Pelvic position was found to be positively correlated with differences between left and right hip flexion (r=0.51), hip abduction (r=0.62), knee flexion (r=0.45), knee abduction (r=0.42), and ankle inversion (r=0.38). In addition, the difference between left and right hip abduction showed a positive correlation with difference between left and right ankle dorsiflexion (r=0.64). Moreover, differences between left and right knee flexion exhibited positive correlations with differences between left and right knee abduction (r=0.41) and ankle inversion (r=0.45). [Conclusion] Bilateral pelvic tilt angles are important as they lead to bilateral differences in lower extremity joint angles during walking.
Withrow, Thomas J; Huston, Laura J; Wojtys, Edward M; Ashton-Miller, James A
2006-02-01
An instrumented cadaveric knee construct was used to quantify the association between impact force, quadriceps force, knee flexion angle, and anterior cruciate ligament relative strain in simulated unipedal jump landings. Anterior cruciate ligament strain will correlate with impact force, quadriceps force, and knee flexion angle. Descriptive laboratory study. Eleven cadaveric knees (age, 70.8 [19.3] years; 5 male; 6 female) were mounted in a custom fixture with the tibia and femur secured to a triaxial load cell. Quadriceps, hamstring, and gastrocnemius muscle forces were simulated using pretensioned steel cables (stiffness, 7 kN/cm), and the quadriceps tendon force was measured using a load cell. Mean strain on the anteromedial bundle of the anterior cruciate ligament was measured using a DVRT. With the knee in 25 degrees of flexion, the construct was vertically loaded by an impact force initially directed 4 cm posterior to the knee joint center. Tibiofemoral kinematics was measured using a 3D optoelectronic tracking system. The increase in anterior cruciate ligament relative strain was proportional to the increase in quadriceps force (r(2) = 0.74; P < .00001) and knee flexion angle (r(2) = 0.88; P < .00001) but was not correlated with the impact force (r(2) = 0.009; P = .08). The increase in knee flexion and quadriceps force during this simulated 1-footed landing strongly influenced the relative strain on the anteromedial bundle of the anterior cruciate ligament. These results suggest that even in the presence of knee flexor muscle forces, the increase in quadriceps force required to prevent the knee from flexing during landing can place the anterior cruciate ligament at risk for large strains.
Magnetic resonance evaluation of the knee in children and adolescents with achondroplasia.
Akyol, Yakup; Averill, Lauren W; Atanda, Alfred; Kecskemethy, Heidi H; Bober, Michael B; Mackenzie, William G
2015-06-01
Achondroplasia is the most common form of skeletal dysplasia. Although the radiographic features are well described, MRI features of the knee in achondroplasia have not been reported. To describe common MRI characteristics of the knee joint in symptomatic children and adolescents with achondroplasia. We retrospectively evaluated 10 knee MRI examinations in 8 children and young adults (age range 11-20 years, mean 16.3 years) with achondroplasia. We measured modified Insall-Salvati index, knee flexion angle, anterior cruciate ligament (ACL)-Blumensaat line angle, ACL-tibial angle, posterior cruciate ligament (PCL) angle, intercondylar notch width index, and intercondylar notch depth index. We compared our findings with an age- and gender-matched control group of 20 children (age range 15-18 years; mean 16 years) with normal knee MRIs. All 10 knees in the achondroplasia group had discoid lateral meniscus; 8 meniscal tears were identified. Patella baja was present in half of the study cases. Greater knee flexion and increased ACL-Blumensaat line and PCL angles were seen in all achondroplasia knees. ACL-tibial angle was similar in the study and in the control group. Children with achondroplasia had deeper A-shape femoral notches that extended more anteriorly than those seen in the control group. MRI findings were confirmed in all seven knees with arthroscopic correlation. Discoid lateral meniscus, often with tear, is a consistent feature in knee MRIs of symptomatic children and adolescents with achondroplasia. Other findings include patella baja, knee flexion, deep A-shape intercondylar notch, increased ACL-Blumensaat line angle and taut PCL.
[Clinical significance of Q-angle under different conditions in recurrent patellar dislocation].
Wang, Zhijie; Chen, You; Li, Anping; Long, Yi
2014-01-01
To investigate the clinical significance of Q-angle measuring under different conditions in female recurrent patellar dislocation female patients. Between August 2012 and March 2013, 10 female patients (11 knees) with recurrent patellar dislocation were collected as trial group; 20 female patients (20 knees) with simple meniscus injury were collected as control group at the same time. Q-angle was measured in extension, 30 degrees flexion, 30 degrees flexion with manual correction, and surgical correction in the trial group, and only in extension and 30 degrees flexion in the control group. Then the difference value of Q-angle between extension and 30 degrees flexion (Q-angle in extension subtracts Q-angle in 30 flexion) were calculated. Independent sample t-test was used to analyze Q-angle degrees in extension, 30 degrees flexion, and the changed degrees of 2 groups. The Q-angle between manual correction and surgical correction of the trial group was analyzed by paired t-test. The Q-angle in extension, Q-angle in 30 degrees flexion, and difference value of Q-angle between extension and 30 degrees flexion were (17.2 +/- 3.6), (14.3 +/- 3.0), and (2.9 +/- 1.9) degrees in the trial group and were (15.2 +/- 3.4), (14.4 +/- 3.5), and (0.8 +/- 1.7) degrees in the control group. No significant difference was found in Q-angle of extension or Q-angle of 30 degrees flexion between 2 groups (P > 0.05), but the difference value of Q-angle between extension and 30 degrees flexion in the trial group was significantly larger than that in the control group (t = 3.253, P = 0.003). The Q-angle in 30 degrees flexion with manual correction and surgical correction in the trial group was (19.8 +/- 3.4) degrees and (18.9 +/- 3.8) degrees respectively, showing no significant difference (t = 2.193, P = 0.053). When a female patient's Q-angle in 30 degrees flexion knee changes obviously compared with Q-angle in extension position, recurrent patellar dislocation should be considered. For female patients with recurrent patellar dislocation, the preoperative Q-angle in 30 degrees flexion with manual correction should be measured, which can help increasing the accuracy of evaluation whether rearrangement should be performed.
Park, Sang Eun; Lee, Chun Taek
2007-10-01
This study was aimed to compare robotic-assisted implantation of a total knee arthroplasty with conventional manual implantation. We controlled, randomized, and reviewed 72 patients for total knee arthroplasty assigned to undergo either conventional manual implantation (excluding navigation-assisted implantation cases) of a Zimmer LPS prosthesis (Zimmer, Warsaw, Ind) (30 patients: group 1) or robotic-assisted implantation of such a prosthesis (32 patients: group 2). The femoral flexion angle (gamma angle) and tibial angle (delta angle) in the lateral x-ray of group 1 were 4.19 +/- 3.28 degrees and 89.7 +/- 1.7 degrees, and those of group 2 were 0.17 +/- 0.65 degrees and 85.5 +/- 0.92 degrees. The major complications were from improper small skin incision during a constraint attempt of minimally invasive surgery and during bulk fixation frame pins insertion. Robotic-assisted technology had definite advantages in terms of preoperative planning, accuracy of the intraoperative procedure, and postoperative follow-up, especially in the femoral flexion angle (gamma angle) and tibial flexion angle (delta angle) in the lateral x-ray, and in the femoral flexion angle (alpha angle) in the anteroposterior x-ray. But a disadvantage was the high complication rate in early stage.
Evaluation of the Microsoft Kinect for screening ACL injury.
Stone, Erik E; Butler, Michael; McRuer, Aaron; Gray, Aaron; Marks, Jeffrey; Skubic, Marjorie
2013-01-01
A study was conducted to evaluate the use of the skeletal model generated by the Microsoft Kinect SDK in capturing four biomechanical measures during the Drop Vertical Jump test. These measures, which include: knee valgus motion from initial contact to peak flexion, frontal plane knee angle at initial contact, frontal plane knee angle at peak flexion, and knee-to-ankle separation ratio at peak flexion, have proven to be useful in screening for future knee anterior cruciate ligament (ACL) injuries among female athletes. A marker-based Vicon motion capture system was used for ground truth. Results indicate that the Kinect skeletal model likely has acceptable accuracy for use as part of a screening tool to identify elevated risk for ACL injury.
Gade, Venkata; Allen, Jerome; Cole, Jeffrey L; Barrance, Peter J
2016-07-01
To characterize the ability of patients with symptomatic knee osteoarthritis (OA) to perform a weight-bearing activity compatible with upright magnetic resonance imaging (MRI) scanning and how this ability is affected by knee pain symptoms and flexion angles. Cross-sectional observational study assessing effects of knee flexion angle, pain level, and study sequence on accuracy and duration of performing a task used in weight-bearing MRI evaluation. Visual feedback of knee position from an MRI compatible sensor was provided. Pain levels were self-reported on a standardized scale. Simulated MRI setup in a research laboratory. Convenience sample of individuals (N=14; 9 women, 5 men; mean, 69±14y) with symptomatic knee OA. Not applicable. Averaged absolute and signed angle error from target knee flexion for each minute of trial and duration tolerance (the duration that subjects maintained position within a prescribed error threshold). Absolute targeting error increased at longer trial durations (P<.001). Duration tolerance decreased with increasing pain (mean ± SE, no pain: 3min 19s±11s; severe pain: 1min 49s±23s; P=.008). Study sequence affected duration tolerance (first knee: 3min 5s±9.1s; second knee: 2min 19s±9.7s; P=.015). The study provided evidence that weight-bearing MRI evaluations based on imaging protocols in the range of 2 to 3 minutes are compatible with patients reporting mild to moderate knee OA-related pain. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Murray, Amanda M; Thomas, Abbey C; Armstrong, Charles W; Pietrosimone, Brian G; Tevald, Michael A
2015-12-01
Abnormal knee joint mechanics have been implicated in the pathogenesis and progression of knee osteoarthritis. Deficits in muscle function (i.e., strength and power) may contribute to abnormal knee joint loading. The associations between quadriceps strength, power and knee joint mechanics remain unclear in knee osteoarthritis. Three-dimensional motion analysis was used to collect peak knee joint angles and moments during the first 50% of stance phase of gait in 33 participants with knee osteoarthritis. Quadriceps strength and power were assessed using a knee extension machine. Strength was quantified as the one repetition maximum. Power was quantified as the peak power produced at 40-90% of the one repetition maximum. Quadriceps strength accounted for 15% of the variance in peak knee flexion angle (P=0.016). Quadriceps power accounted for 20-29% of the variance in peak knee flexion angle (P<0.05). Quadriceps power at 90% of one repetition maximum accounted for 9% of the variance in peak knee adduction moment (P=0.05). These data suggest that quadriceps power explains more variance in knee flexion angle and knee adduction moment during gait in knee osteoarthritis than quadriceps strength. Additionally, quadriceps power at multiple loads is associated with knee joint mechanics and therefore should be assessed at a variety of loads. Taken together, these results indicate that quadriceps power may be a potential target for interventions aimed at changing knee joint mechanics in knee osteoarthritis. Copyright © 2015 Elsevier Ltd. All rights reserved.
Ishii, Yoshinori; Noguchi, Hideo; Takeda, Mitsuhiro; Sato, Junko; Sakurai, Tetsuya; Toyabe, Shin-Ichi
2014-08-01
Anteroposterior (AP) joint translation is an important indicator of good clinical outcome following total knee arthroplasty (TKA). This study evaluated the in vivo relationship between changes in the degree of voluntary soft tissue tension and flexion angle versus simultaneous AP translation after TKA. A posterior cruciate ligament (PCL)-retaining meniscal-bearing design was investigated in 20 knees of 20 patients. AP translation was measured at 30° and 75° flexion with the KT-2000 arthrometer while patients were anesthetized and non-anesthetized. The mean translations at 30° and 75° were 10.5 and 10.4 mm, respectively, in non-anesthetized patients and 13.8 and 12.7 mm, respectively, in patients under anesthesia. AP translation showed a significant positive correlation with soft tissue tension (p < 0.001), but not with flexion angle (p = 0.366). No interaction was observed between soft tissue tension and the flexion angle in terms of AP translation (p = 0.431). Surgeons should recognize that AP translation is greater in anesthetized patients than in non-anesthetized patients, regardless of the flexion angle, with no significant correlation between flexion angle and translation, regardless of the level of consciousness. Because conformity between the tibial insert and femoral component decreases with flexion, whereas the opposing effects of supporting structures, such as muscles, ligaments, and capsules, increases, proper soft tissue tension, particularly retention of a functional PCL, could have an important role in determining AP translation in the current prosthesis design.
Pollard, Christine D.; Sigward, Susan M.; Powers, Christopher M.
2009-01-01
Background It has been proposed that female athletes who limit knee and hip flexion during athletic tasks rely more on the passive restraints in the frontal plane to deceleration their body center of mass. This biomechanical pattern is thought to increase the risk for anterior cruciate ligament injury. To date, the relationship between sagittal plane kinematics and frontal plane knee motion and moments has not been explored. Methods Subjects consisted of fifty-eight female club soccer players (age range: 11 to 20 years) with no history of knee injury. Kinematics, ground reaction forces, and surface electromyography were collected while each subject performed a drop landing task. Subjects were divided into two groups based on combined sagittal plane knee and hip flexion angles during the deceleration phase of landing (high flexion and low flexion). Findings Subjects in the low flexion group demonstrated increased knee valgus angles (P = 0.02, effect size 0.27), increased knee adductor moments (P = 0.03, effect size 0.24), decreased energy absorption at the knee and hip (P = 0.02, effect size 0.25; and P< 0.001, effect size 0.59), and increased vastus lateralis EMG when compared to subjects in the high flexion group (P = 0.005, effect size 0.35). Interpretation Female athletes with limited sagittal plane motion during landing exhibit a biomechanical profile that may put these individuals at greater risk for anterior cruciate ligament injury. PMID:19913961
Oñate, James A; Guskiewicz, Kevin M; Marshall, Stephen W; Giuliani, Carol; Yu, Bing; Garrett, William E
2005-06-01
Anterior cruciate ligament injury prevention programs have used videotapes of jump-landing technique as a key instructional component to improve landing performance. All videotape feedback model groups will increase knee flexion angles at initial contact and overall knee flexion motion and decrease peak vertical ground reaction forces and peak proximal anterior tibial shear forces to a greater extent than will a nonfeedback group. The secondary hypothesis is that the videotape feedback using the combination of the expert and self models will create the greatest change in each variable. Controlled laboratory study. Knee kinematics and kinetics of college-aged recreational athletes randomly placed in 3 different videotape feedback model groups (expert only, self only, combination of expert and self) and a nonfeedback group were collected while participants performed a basketball jump-landing task on 3 testing occasions. All feedback groups significantly increased knee angular displacement flexion angles [F(6,70) = 8.03, P = .001] and decreased peak vertical ground reaction forces [F(6,78) = 2.68, P = .021] during performance and retention tests. The self and combination groups significantly increased knee angular displacement flexion angles more than the control group did; the expert model group did not change significantly more than the control group did. All feedback groups and the nonfeedback group significantly reduced peak vertical forces across performance and retention tests. There were no statistically significant changes in knee flexion angle at initial ground contact (P = .111) and peak proximal anterior tibial shear forces (P = .509) for both testing sessions for each group. The use of self or combination videotape feedback is most useful for increasing knee angular displacement flexion angles and reducing peak vertical forces during landing. The use of self or combination modeling is more effective than is expert-only modeling for the implementation of instructional programs aimed at reducing the risk of jump-landing anterior cruciate ligament injuries.
Cao, Wujing; Yu, Hongliu; Zhao, Weiliang; Meng, Qiaoling; Chen, Wenming
2018-04-20
The microprocessor-controlled prosthetic knees have been introduced to transfemoral amputees due to advances in biomedical engineering. A body of scientific literature has shown that the microprocessor-controlled prosthetic knees improve the gait and functional abilities of persons with transfemoral amputation. The aim of this study was to propose a new microprocessor-controlled prosthetic knee (MPK) and compare it with non-microprocessor-controlled prosthetic knees (NMPKs) under different walking speeds. The microprocessor-controlled prosthetic knee (i-KNEE) with hydraulic damper was developed. The comfortable self-selected walking speeds of 12 subjects with i-KNEE and NMPK were obtained. The maximum swing flexion knee angle and gait symmetry were compared in i-KNEE and NMPK condition. The comfortable self-selected walking speeds of some subjects were higher with i-KNEE while some were not. There was no significant difference in comfortable self-selected walking speed between the i-KNEE and the NMPK condition (P= 0.138). The peak prosthetic knee flexion during swing in the i-KNEE condition was between sixty and seventy degree under any walking speed. In the NMPK condition, the maximum swing flexion knee angle changed significantly. And it increased with walking speed. There is no significant difference in knee kinematic symmetry when the subjects wear the i-KNEE or NMPK. The results of this study indicated that the new microprocessor-controlled prosthetic knee was suitable for transfemoral amputees. The maximum swing flexion knee angle under different walking speeds showed different properties in the NMPK and i-KNEE condition. The i-KNEE was more adaptive to speed changes. There was little difference of comfortable self-selected walking speed between i-KNEE and NMPK condition.
Chen, CH; Li, JS; Hosseini, A; Gadikota, HR; Gill, TJ; Li, G
2011-01-01
Quadriceps avoidance and higher flexion strategy have been assumed as effects of ACL deficiency on knee joint function during gait. However, the effect of ACL deficiency on anteroposterior stability of the knee during gait is not well defined. In this study, ten patients with unilateral acute ACL ruptures and the contralateral side intact performed gait on a treadmill. Flexion angles and anteroposterior translation of the ACL injured and the intact controlateral knees were measured at every 10% of the stance phase of the gait (from heel strike to toe-off) using a combined MRI and dual fluoroscopic image system (DFIS). The data indicated that during the stance phase of the gait, the ACL-deficient knees showed higher flexion angles compared to the intact contralateral side, consistent with the assumption of a higher flexion gait strategy. However, the data also revealed that the ACL-deficient knees had higher anterior tibial translation compared to the intact contralateral side during the stance phase of the gait. The higher flexion gait strategy was not shown to correlate to a reduction of the anterior tibial translation in ACL deficient knees. These data may provide indications for conservative treatment or surgical reconstruction of the ACL injured knees in restoration of the knee kinematics during daily walking activities. PMID:22169387
Becher, Christoph; Fleischer, Benjamin; Rase, Marten; Schumacher, Thees; Ettinger, Max; Ostermeier, Sven; Smith, Tomas
2017-08-01
This study analysed the effects of upright weight bearing and the knee flexion angle on patellofemoral indices, determined using magnetic resonance imaging (MRI), in patients with patellofemoral instability (PI). Healthy volunteers (control group, n = 9) and PI patients (PI group, n = 16) were scanned in an open-configuration MRI scanner during upright weight bearing and supine non-weight bearing positions at full extension (0° flexion) and at 15°, 30°, and 45° flexion. Patellofemoral indices included the Insall-Salvati Index, Caton-Deschamp Index, and Patellotrochlear Index (PTI) to determine patellar height and the patellar tilt angle (PTA), bisect offset (BO), and the tibial tubercle-trochlear groove (TT-TG) distance to assess patellar rotation and translation with respect to the femur and alignment of the extensor mechanism. A significant interaction effect of weight bearing by flexion angle was observed for the PTI, PTA, and BO for subjects with PI. At full extension, post hoc pairwise comparisons revealed a significant effect of weight bearing on the indices, with increased patellar height and increased PTA and BO in the PI group. Except for the BO, no such changes were seen in the control group. Independent of weight bearing, flexing the knee caused the PTA, BO, and TT-TG distance to be significantly reduced. Upright weight bearing and the knee flexion angle affected patellofemoral MRI indices in PI patients, with significantly increased values at full extension. The observations of this study provide a caution to be considered by professionals when treating PI patients. These patients should be evaluated clinically and radiographically at full extension and various flexion angles in context with quadriceps engagement. Explorative case-control study, Level III.
Ishida, Kazunari; Shibanuma, Nao; Matsumoto, Tomoyuki; Sasaki, Hiroshi; Takayama, Koji; Matsuzaki, Tokio; Tei, Katsumasa; Kuroda, Ryosuke; Kurosaka, Masahiro
2016-01-01
To investigate whether intraoperative kinematics obtained by navigation systems can be divided into several kinematic patterns and to assess the correlation between the intraoperative kinematics with maximum flexion angles before and after total knee arthroplasty (TKA). Fifty-four posterior-stabilised (PS) TKA implanted using an image-free navigation system were evaluated. At registration and after implantation, tibial internal rotation angles at maximum extension, 30°, 45°, 60°, 90°, and maximum flexion were collected. The rotational patterns were divided into four groups and were examined the correlation with maximum flexion before and after operation. Tibial internal rotation from 90° of flexion to maximum flexion at registration was correlated with maximum flexion angles pre- and postoperatively. The four groups showed statistically different kinematic patterns. The group with tibial external rotation up to 90° of flexion, following tibial internal rotation at registration, achieved better flexion angles, compared to those of another groups (126.7° ± 12.0°, p < 0.05). The group with tibial external rotation showed the worst flexion angles (80.0° ± 40.4°, p < 0.05). Furthermore, the group with limited extension showed worse flexion angles (111.6° ± 8.9°, p < 0.05). Navigation-based kinematic patterns found at registration predict postoperative maximum flexion angle in PS TKA. Navigation-based kinematics can be useful information during TKA surgery. Diagnostic studies, development of diagnostic criteria in a consecutive series of patients and a universally applied "gold" standard, Level II.
Arthrometric Evaluation of Stabilizing Effect of Knee Functional Bracing at Different Flexion Angles
Seyed Mohseni, Saeedeh; Moss, Farzam; Karimi, Hossein; Kamali, Mohammad
2009-01-01
Previous in-vivo investigations on the stabilizing efficacy of knee bracing for ACL reconstructed patients have been often limited to 20-30 degrees of knee flexion. In this study, the effectiveness of a uniaxial hinged functional brace to improve the knee stability was assessed at 30, 60 and 90 degrees of knee flexion. Arthrometry tests were conducted on 15 healthy subjects before and following wearing the brace and the tibial displacements were measured at up to 150 N anterior forces. Results indicated that functional bracing has a significant stabilizing effect throughout the range of knee flexion examined (p < 0.05). The rate of effectiveness, however, was not consistent across the flexion range, e.g., 50% at 30 degrees and only 4% at 90 degrees. It was suggested that accurate sizing and fitting as well as attention to correct hinge placement relative to the femoral condyles can limit brace migration and improve its effectiveness in mid and deep knee flexion. With using adaptive limb fittings, through flexible pads, and a polycentric joint a more significant improvement of the overall brace performance and efficacy might be obtained. Key points Functional bracing improves the knee joint stability mostly in extension posture. Unlike the non-braced condition, the least knee joint stability appears in mid and deep flexion angles when using a hinged brace. Accurate sizing and fitting and attention to correct hinge placement relative to the femoral condyles can limit brace migration and improve its effectiveness in mid and deep knee flexion. The overall brace performance and efficacy might be improved significantly using adaptive limb fittings through flexible pads and/or polycentric joints. PMID:24149533
Freedman, Benjamin R; Sheehan, Frances T; Lerner, Amy L
2015-10-01
Several factors are believed to contribute to patellofemoral joint function throughout knee flexion including patellofemoral (PF) kinematics, contact, and bone morphology. However, data evaluating the PF joint in this highly flexed state have been limited. Therefore, the purpose of this study was to evaluate patellofemoral contact and alignment in low (0°), moderate (60°), and deep (140°) knee flexion, and then correlate these parameters to each other, as well as to femoral morphology. Sagittal magnetic resonance images were acquired on 14 healthy female adult knees (RSRB approved) using a 1.5 T scanner with the knee in full extension, mid-flexion, and deep flexion. The patellofemoral cartilage contact area, lateral contact displacement (LCD), cartilage thickness, and lateral patellar displacement (LPD) throughout flexion were defined. Intra- and inter-rater repeatability measures were determined. Correlations between patellofemoral contact parameters, alignment, and sulcus morphology were calculated. Measurement repeatability ICCs ranged from 0.94 to 0.99. Patellofemoral cartilage contact area and thickness, LCD, and LPD were statistically different throughout all levels of flexion (p<0.001). The cartilage contact area was correlated to LPD, cartilage thickness, sulcus angle, and epicondylar width (r=0.47-0.72, p<0.05). This study provides a comprehensive analysis of the patellofemoral joint throughout its range of motion. This study agrees with past studies that investigated patellofemoral measures at a single flexion angle, and provides new insights into the relationship between patellofemoral contact and alignment at multiple flexion angles. The study provides a detailed analysis of the patellofemoral joint in vivo, and demonstrates the feasibility of using standard clinical magnetic resonance imaging scanners to image the knee joint in deep flexion. Copyright © 2015 Elsevier B.V. All rights reserved.
Masuda, S; Furumatsu, T; Okazaki, Y; Kodama, Y; Hino, T; Kamatsuki, Y; Miyazawa, S; Ozaki, T
2018-04-10
A medial meniscus posterior root tear (MMPRT) is defined as an injury to the posterior meniscal insertion on the tibia. In MMPRT, the medial meniscus (MM) hoop function is damaged, and the MM undergoes a medial extrusion into the interior from the superior articular surface of the tibia. However, the details of MM position and movement during knee joint movement are unclear in MMPRT cases. The present study aims to evaluate MM position and movement via magnetic resonance imaging (MRI) examination of the MM posterior extrusion (MMPE) at knee flexion angles of 10° and 90°. We hypothesized that, during knee flexion, the MM will shift to the posterior and the posterior extrusion will increase compared to that when the knee is extended. Twenty-four patients were diagnosed with symptomatic MMPRT on open MRI examination. Preoperative MMPE, anteroposterior interval (API) of the MM, and MM medial extrusion (MMME) at knee flexion angles of 10° and 90° were measured. For patients with MMPRT, the MMPE increased from -4.77±1.43mm to 3.79±1.17mm (p<0.001) when the knee flexion angle increased from 10° to 90°. Further, flexing the knee from 10° to 90° decreased the API of the MM from 20.19±4.22mm to 16.41±5.14mm (p<0.001). MMME showed no significant change between knee flexion angles of 10° and 90°. This study demonstrated that, in cases of MMPRT, the MMPE clearly increases when the knee is flexed to 90°, while MMME does not change. Our results suggest that open MRI examination can be used to evaluate the dynamic position of the posterior MM by scanning the knee as it flexes to 90°. IV: retrospective cohort study. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Malfait, Bart; Dingenen, Bart; Smeets, Annemie; Staes, Filip; Pataky, Todd; Robinson, Mark A.; Vanrenterghem, Jos; Verschueren, Sabine
2016-01-01
Purpose The purpose was to assess if variation in sagittal plane landing kinematics is associated with variation in neuromuscular activation patterns of the quadriceps-hamstrings muscle groups during drop vertical jumps (DVJ). Methods Fifty female athletes performed three DVJ. The relationship between peak knee and hip flexion angles and the amplitude of four EMG vectors was investigated with trajectory-level canonical correlation analyses over the entire time period of the landing phase. EMG vectors consisted of the {vastus medialis(VM),vastus lateralis(VL)}, {vastus medialis(VM),hamstring medialis(HM)}, {hamstring medialis(HM),hamstring lateralis(HL)} and the {vastus lateralis(VL),hamstring lateralis(HL)}. To estimate the contribution of each individual muscle, linear regressions were also conducted using one-dimensional statistical parametric mapping. Results The peak knee flexion angle was significantly positively associated with the amplitudes of the {VM,HM} and {HM,HL} during the preparatory and initial contact phase and with the {VL,HL} vector during the peak loading phase (p<0.05). Small peak knee flexion angles were significantly associated with higher HM amplitudes during the preparatory and initial contact phase (p<0.001). The amplitudes of the {VM,VL} and {VL,HL} were significantly positively associated with the peak hip flexion angle during the peak loading phase (p<0.05). Small peak hip flexion angles were significantly associated with higher VL amplitudes during the peak loading phase (p = 0.001). Higher external knee abduction and flexion moments were found in participants landing with less flexed knee and hip joints (p<0.001). Conclusion This study demonstrated clear associations between neuromuscular activation patterns and landing kinematics in the sagittal plane during specific parts of the landing. These findings have indicated that an erect landing pattern, characterized by less hip and knee flexion, was significantly associated with an increased medial and posterior neuromuscular activation (dominant hamstrings medialis activity) during the preparatory and initial contact phase and an increased lateral neuromuscular activation (dominant vastus lateralis activity) during the peak loading phase. PMID:27101130
Changes of contact pressure and area in patellofemoral joint after different meniscectomies.
Bai, Bo; Shun, Hui; Yin, Zhi Xun; Liao, Zhuang-Wen; Chen, Ni
2012-05-01
We investigated the contact pressure and area of the patellofemoral joint both before and after different meniscectomies to provide a biomechanical basis for selecting meniscectomy and its clinical application for meniscus injuries. Six fresh cadaveric knees were used in the study. Using Staubli robots and an ultra-low-min-type pressure-sensitive tablet, changes in contact area and stress in the patellofemoral joint were measured at various flexion angles following different parts and degrees of meniscectomy. The patellofemoral contact area enlarged with the increase of knee flexion angle. From the values obtained from contact areas and average contact pressure of the patellofemoral joint, we found no significant difference between partial meniscectomy and intact knees, but a significant difference was found between total meniscectomy and intact knees. The contact area after lateral meniscectomy was statistically less than that of intact knees. The mean patellofemoral contact pressure after lateral meniscectomy was larger than in intact knees at each angle of flexion. No significant difference in contact area was observed between intact knees and medial meniscectomy. The average patellofemoral contact pressure after medial meniscectomy was larger than in intact knees from 0° ~ 30° of knee flexion, and no significant differences were found between intact knees and medial meniscectomy while knee bending from 60° to 90°. Different meniscectomies result in high contact pressure or disordered distribution of contact pressure, which may be the cause of postoperative patellofemoral degenerative arthrosis.
Herbort, Mirco; Michel, Philipp; Raschke, Michael J; Vogel, Nils; Schulze, Martin; Zoll, Alexander; Fink, Christian; Petersen, Wolf; Domnick, Christoph
2017-03-01
Semitendinosus and gracilis muscles are frequently harvested for autologous tendon grafts for cruciate ligament reconstruction. This study investigated the joint-stabilizing effects of these hamstring muscles in cases of insufficiency of the medial collateral ligament (MCL). First, both the semitendinosus and gracilis muscles can actively stabilize the joint against valgus moments in the MCL-deficient knee. Second, the stabilizing influence of these muscles decreases with an increasing knee flexion angle. Controlled laboratory study. The kinematics was examined in 10 fresh-frozen human cadaveric knees using a robotic/universal force moment sensor system and an optical tracking system. The knee kinematics under 5- and 10-N·m valgus moments were determined in the different flexion angles of the (1) MCL-intact and (2) MCL-deficient knee using the following simulated muscle loads: (1) 0-N (idle) load, (2) 200-N semitendinosus (ST) load, and (3) 280-N (200/80-N) combined semitendinosus/gracilis (STGT) load. Cutting the MCL increased the valgus angle under all tested conditions and angles compared with the MCL-intact knee by 4.3° to 8.1° for the 5-N·m valgus moment and 6.5° to 11.9° for the 10-N·m valgus moment ( P < .01). The applied 200-N simulated ST load reduced the valgus angle significantly at 0°, 10°, 20°, and 30° of flexion under 5- and 10-N·m valgus moments ( P < .05). At 0°, 10°, and 20° of flexion, these values were close to those for the MCL-intact joint under the respective moments (both P > .05). The combined 280-N simulated STGT load significantly reduced the valgus angle in 0°, 10°, and 20° of flexion under 5- and 10-N·m valgus moments ( P < .05) to values near those for the intact joint (5 N·m: 0°, 10°; 10 N·m: 0°, 10°, 20°; P > .05). In 60° and 90° of flexion, ST and STGT loads did not decrease the resulting valgus angle of the MCL-deficient knee without hamstring loads ( P > .05 vs deficient; P = .0001 vs intact). In this human cadaveric study, semitendinosus and gracilis muscles successfully stabilize valgus moments applied to the MCL-insufficient knee when the knee is near extension. In the valgus-unstable knee, these data suggest that the hamstring muscles should be preserved in (multi-) ligament surgery when possible.
Differences in Lower Extremity and Trunk Kinematics between Single Leg Squat and Step Down Tasks
Lewis, Cara L.; Foch, Eric; Luko, Marc M.; Loverro, Kari L.; Khuu, Anne
2015-01-01
The single leg squat and single leg step down are two commonly used functional tasks to assess movement patterns. It is unknown how kinematics compare between these tasks. The purpose of this study was to identify kinematic differences in the lower extremity, pelvis and trunk between the single leg squat and the step down. Fourteen healthy individuals participated in this research and performed the functional tasks while kinematic data were collected for the trunk, pelvis, and lower extremities using a motion capture system. For the single leg squat task, the participant was instructed to squat as low as possible. For the step down task, the participant was instructed to stand on top of a box, slowly lower him/herself until the non-stance heel touched the ground, and return to standing. This was done from two different heights (16cm and 24cm). The kinematics were evaluated at peak knee flexion as well as at 60° of knee flexion. Pearson correlation coefficients (r) between the angles at those two time points were also calculated to better understand the relationship between each task. The tasks resulted in kinematics differences at the knee, hip, pelvis, and trunk at both time points. The single leg squat was performed with less hip adduction (p ≤ 0.003), but more hip external rotation and knee abduction (p ≤ 0.030), than the step down tasks at 60° of knee flexion. These differences were maintained at peak knee flexion except hip external rotation was only significant in the 24cm step down task (p ≤ 0.029). While there were multiple differences between the two step heights at peak knee flexion, the only difference at 60° of knee flexion was in trunk flexion (p < 0.001). Angles at the knee and hip had a moderate to excellent correlation (r = 0.51–0.98), but less consistently so at the pelvis and trunk (r = 0.21–0.96). The differences in movement patterns between the single leg squat and the step down should be considered when selecting a single leg task for evaluation or treatment. The high correlation of knee and hip angles between the three tasks indicates that similar information about knee and hip kinematics was gained from each of these tasks, while pelvis and trunk angles were less well predicted. PMID:25955321
Chong, Helen C; Tennant, Liana M; Kingston, David C; Acker, Stacey M
2017-03-01
(1) Characterize knee joint moments and peak knee flexion moment timing during kneeling transitions, with the intent of identifying high-risk postures. (2) Determine whether safety footwear worn by kneeling workers (construction workers, tile setters, masons, roofers) alters high flexion kneeling mechanics. Fifteen males performed high flexion kneeling transitions. Kinetics and kinematics were analyzed for differences in ascent and descent in the lead and trail legs. Mean±standard deviation peak external knee adduction and flexion moments during transitions ranged from 1.01±0.31 to 2.04±0.66% body weight times height (BW∗Ht) and from 3.33 to 12.6% BW∗Ht respectively. The lead leg experienced significantly higher adduction moments compared to the trail leg during descent, when work boots were worn (interaction, p=0.005). There was a main effect of leg (higher lead vs. trail) on the internal rotation moment in both descent (p=0.0119) and ascent (p=0.0129) phases. Peak external knee adduction moments during transitions did not exceed those exhibited during level walking, thus increased knee adduction moment magnitude is likely not a main factor in the development of knee OA in occupational kneelers. Additionally, work boots only significantly increased the adduction moment in the lead leg during descent. In cases where one knee is painful, diseased, or injured, the unaffected knee should be used as the lead leg during asymmetric bilateral kneeling. Peak flexion moments occurred at flexion angles above the maximum flexion angle exhibited during walking (approximately 60°), supporting the theory that the loading of atypical surfaces may aid disease development or progression. Copyright © 2016 Elsevier B.V. All rights reserved.
Seymore, Kayla D; Cameron, Sarah E; Kaplan, Jonathan T; Ramsay, John W; Brown, Tyler N
2017-12-08
This study quantified how a dual cognitive task impacts lower limb biomechanics during anticipated and unanticipated single-leg cuts with body borne load. Twenty-four males performed anticipated and unanticipated cuts with and without a dual cognitive task with three load conditions: no load (∼6 kg), medium load (15% of BW), and heavy load (30% of BW). Lower limb biomechanics were submitted to a repeated measures linear mixed model to test the main and interaction effects of load, anticipation, and dual task. With body borne load, participants increased peak stance (PS) hip flexion (p = .004) and hip internal rotation (p = .001) angle, and PS hip flexion (p = .001) and internal rotation (p = .018), and knee flexion (p = .016) and abduction (p = .001) moments. With the dual task, participants decreased PS knee flexion angle (p < .001) and hip flexion moment (p = .027), and increased PS knee external rotation angle (p = .034). During the unanticipated cut, participants increased PS hip (p = .040) and knee flexion angle (p < .001), and decreased PS hip adduction (p = .001), and knee abduction (p = .005) and external rotation (p = .026) moments. Adding body borne load produces lower limb biomechanical adaptations thought to increase risk of musculoskeletal injury, but neither anticipation nor dual task exaggerated those biomechanical adaptations. With a dual task, participants adopted biomechanics known to increase injury risk; whereas, participants used lower limb biomechanics thought to decrease injury risk during unanticipated cuts. Copyright © 2017 Elsevier Ltd. All rights reserved.
Richards, Jim; Thewlis, Dominic; Selfe, James; Cunningham, Andrew; Hayes, Colin
2008-01-01
Context: Single-limb squats on a decline angle have been suggested as a rehabilitative intervention to target the knee extensors. Investigators, however, have presented very little empirical research in which they have documented the biomechanics of these exercises or have determined the optimum angle of decline used. Objective: To determine the involvement of the gastrocnemius and rectus femoris muscles and the external ankle and knee joint moments at 60° of knee flexion while performing a single-limb squat at different decline angles. Design: Participants acted as their own controls in a repeated-measures design. Patients or Other Participants: We recruited 10 participants who had no pain, injury, or neurologic disorder. Intervention(s): Participants performed single-limb squats at different decline angles. Main Outcome Measure(s): Angle-specific knee and ankle moments were calculated at 60° of knee flexion. Angle-specific electromyography (EMG) activity was calculated at 60° of knee flexion. Integrated EMG also was calculated to determine the level of muscle activity over the entire squat. Results: An increase was seen in the knee moments (P < .05) and integrated EMG in the rectus femoris (P < .001) as the decline angle increased. A decrease was seen in the ankle moments as the decline angle increased (P = .001), but EMG activity in the gastrocnemius increased between 16° and 24° (P = .018). Conclusions: As the decline angle increased, the knee extensor moment and EMG activity increased. As the decline angle increased, the ankle plantar-flexor moments decreased; however, an increase in the EMG activity was seen with the 24° decline angle compared with the 16° decline angle. This indicates that decline squats at an angle greater than 16° may not reduce passive calf tension, as was suggested previously, and may provide no mechanical advantage for the knee. PMID:18833310
Mizu-Uchi, Hideki; Colwell, Clifford W; Fukagawa, Shingo; Matsuda, Shuichi; Iwamoto, Yukihide; D'Lima, Darryl D
2012-10-01
We constructed patient-specific models from computed tomography data after total knee arthroplasty to predict knee flexion based on implant-bone impingement. The maximum flexion before impingement between the femur and the tibial insert was computed using a musculoskeletal modeling program (KneeSIM; LifeModeler, Inc, San Clemente, California) during a weight-bearing deep knee bend. Postoperative flexion was measured in a clinical cohort of 21 knees (low-flex group: 6 knees with <100° of flexion and high-flex group: 15 size-matched knees with >125° of flexion at 2 years). Average predicted flexion angles were within 2° of clinical measurements for the high-flex group. In the low-flex group, 4 cases had impingement involving the bone cut at the posterior condyle, and the average predicted knee flexion was 102° compared with 93° measured clinically. These results indicate that the level of the distal femoral resection should be carefully planned and that exposed bone proximal to the tips of the posterior condyles of the femoral component should be removed if there is risk of impingement. Copyright © 2012 Elsevier Inc. All rights reserved.
Hahn, Daniel; Herzog, Walter; Schwirtz, Ansgar
2014-08-01
Force and torque production of human muscles depends upon their lengths and contraction velocity. However, these factors are widely assumed to be independent of each other and the few studies that dealt with interactions of torque, angle and angular velocity are based on isolated single-joint movements. Thus, the purpose of this study was to determine force/torque-angle and force/torque-angular velocity properties for multi-joint leg extensions. Human leg extension was investigated (n = 18) on a motor-driven leg press dynamometer while measuring external reaction forces at the feet. Extensor torque in the knee joint was calculated using inverse dynamics. Isometric contractions were performed at eight joint angle configurations of the lower limb corresponding to increments of 10° at the knee from 30 to 100° of knee flexion. Concentric and eccentric contractions were performed over the same range of motion at mean angular velocities of the knee from 30 to 240° s(-1). For contractions of increasing velocity, optimum knee angle shifted from 52 ± 7 to 64 ± 4° knee flexion. Furthermore, the curvature of the concentric force/torque-angular velocity relations varied with joint angles and maximum angular velocities increased from 866 ± 79 to 1,238 ± 132° s(-1) for 90-50° knee flexion. Normalised eccentric forces/torques ranged from 0.85 ± 0.12 to 1.32 ± 0.16 of their isometric reference, only showing significant increases above isometric and an effect of angular velocity for joint angles greater than optimum knee angle. The findings reveal that force/torque production during multi-joint leg extension depends on the combined effects of angle and angular velocity. This finding should be accounted for in modelling and optimisation of human movement.
Chen, Chih-Hui; Li, Jing-Sheng; Hosseini, Ali; Gadikota, Hemanth R; Gill, Thomas J; Li, Guoan
2012-03-01
Quadriceps avoidance and higher flexion strategies have been assumed as effects of ACL deficiency on knee joint function during gait. However, the effect of ACL deficiency on anteroposterior stability of the knee during gait is not well defined. In this study, 10 patients with unilateral acute ACL ruptures and the contralateral side intact performed gait on a treadmill. Flexion angles and anteroposterior translation of the ACL injured and the intact controlateral knees were measured at every 10% of the stance phase of the gait (from heel strike to toe-off) using a combined MRI and dual fluoroscopic imaging system (DFIS). The data indicated that during the stance phase of the gait, the ACL-deficient knees showed higher flexion angles compared to the intact contralateral side, consistent with the assumption of a higher flexion gait strategy. However, the data also revealed that the ACL-deficient knees had higher anterior tibial translation compared to the intact contralateral side during the stance phase of the gait. The higher flexion gait strategy was not shown to correlate to a reduction of the anterior tibial translation in ACL deficient knees. These data may provide indications for conservative treatment or surgical reconstruction of the ACL injured knees in restoration of the knee kinematics during daily walking activities. Copyright © 2011 Elsevier B.V. All rights reserved.
Miyamoto, N; Hirata, K; Kanehisa, H
2017-01-01
The purpose of this study was to examine whether the effects of hamstring stretching on the passive stiffness of each of the long head of the biceps femoris (BFl), semitendinosus (ST), and semimembranosus (SM) vary between passive knee extension and hip flexion stretching maneuvers. In 12 male subjects, before and after five sets of 90 s static stretching, passive lengthening measurements where knee or hip joint was passively rotated to the maximal range of motion (ROM) were performed. During the passive lengthening, shear modulus of each muscle was measured by ultrasound shear wave elastography. Both stretching maneuvers significantly increased maximal ROM and decreased passive torque at a given joint angle. Passive knee extension stretching maneuver significantly reduced shear modulus at a given knee joint angle in all of BFl, ST, and SM. In contrast, the stretching effect by passive hip flexion maneuver was significant only in ST and SM. The present findings indicate that the effects of hamstring stretching on individual passive muscles' stiffness vary between passive knee extension and hip flexion stretching maneuvers. In terms of reducing the muscle stiffness of BFl, stretching of the hamstring should be performed by passive knee extension rather than hip flexion. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Lura, Derek J; Wernke, Matthew M; Carey, Stephanie L; Kahle, Jason T; Miro, Rebecca M; Highsmith, M Jason
2015-02-01
Microprocessor knees have improved the gait and functional abilities of persons with transfemoral amputation. The Genium prosthetic knee offers an advanced sensor and control system designed to decrease impairment by: allowing greater stance phase flexion, easing transitions between gait phases, and compensating for changes in terrain. The aim of this study was to determine differences between the knee flexion angle of persons using the Genium knee, the C-Leg knee, and non-amputee controls; and to evaluate the impact the prostheses on gait and level of impairment of the user. This study used a randomized experimental crossover of persons with transfemoral amputation using the Genium and C-Leg microprocessor knees (n=25), with an observational sample of non-amputee controls (n=5). Gait analysis by 3D motion tracking of subjects ambulating at different speeds on level ground and on 5° and 10° ramps was completed. Use of the Genium resulted in a significant increase in peak knee flexion for swing (5°, p<0.01, d=0.34) and stance (2°, p<0.01, d=0.19) phases relative to C-Leg use. There was a high degree of variability between subjects, and significant differences still remain between the Genium group and the control group's knee flexion angles for most speeds and slopes. The Genium knee generally increases flexion in swing and stance, potentially decreasing the level of impairment for persons with transfemoral amputation. This study demonstrates functional differences between the C-Leg and Genium knees to help prosthetists determine if the Genium will provide functional benefits to individual patients. Copyright © 2014 Elsevier Ltd. All rights reserved.
Biscarini, Andrea; Botti, Fabio M; Pettorossi, Vito E
2013-02-01
We developed a biomechanical model to determine the joint torques and loadings during squatting with a backward/forward-inclined Smith machine. The Smith squat allows a large variety of body positioning (trunk tilt, foot placement, combinations of joint angles) and easy control of weight distribution between forefoot and heel. These distinctive aspects of the exercise can be managed concurrently with the equipment inclination selected to unload specific joint structures while activating specific muscle groups. A backward (forward) equipment inclination decreases (increases) knee torque, and compressive tibiofemoral and patellofemoral forces, while enhances (depresses) hip and lumbosacral torques. For small knee flexion angles, the strain-force on the posterior cruciate ligament increases (decreases) with a backward (forward) equipment inclination, whereas for large knee flexion angles, this behavior is reversed. In the 0 to 60 degree range of knee flexion angles, loads on both cruciate ligaments may be simultaneously suppressed by a 30 degree backward equipment inclination and selecting, for each value of the knee angle, specific pairs of ankle and hip angles. The anterior cruciate ligament is safely maintained unloaded by squatting with backward equipment inclination and uniform/forward foot weight distribution. The conditions for the development of anterior cruciate ligament strain forces are clearly explained.
Ishikawa, Yoshinori; Miyakoshi, Naohisa; Hongo, Michio; Kasukawa, Yuji; Kudo, Daisuke; Shimada, Yoichi
2017-03-01
Spinal deformities can affect quality of life (QOL) and risk of falling, but no studies have explored the relationships of spinal mobility and sagittal alignment of spine and the lower extremities simultaneously. Purpose of this study is to clarify the relationship of those postural parameters to QOL and risk of falling. The study evaluated 110 subjects (41 men, 69 women; mean age, 73 years). Upright and flexion and extension angles for thoracic kyphosis, lumbar lordosis, and spinal inclination were evaluated with SpinalMouse ® . Total-body inclination and hip and knee flexion angles in upright position were measured from lateral photographs. Subjects were divided into Fallers (n=23, 21%) and Non-fallers (n=87, 79%) based on past history of falls. QOL was assessed using the Short Form 36 Health Survey (SF-36 ® ). Age, total-body inclination, spinal inclination upright and in extension, thoracic kyphosis in flexion, lumbar lordosis upright and in extension, and knee flexion correlated significantly with the SF-36. Multiple regression analysis revealed total-body inclination and knee flexion to have the most significant relationships with the SF-36. SF-36, total-body inclination, spinal inclination in extension, thoracic kyphosis in flexion, lumbar lordosis upright and in extension, and hip and knee flexion angles differed significantly between Fallers and Non-fallers (P<0.05 for all). Multivariate logistic regression analyses revealed lumbar lordosis in extension to be a significant predictor of falling (P=0.038). Forward-stooped posture and knee-flexion deformity could be important indicator of lower QOL. Moreover, limited extension in the lumbar spine could be a useful screening examination for fall prevention in the elderly. Copyright © 2017 Elsevier B.V. All rights reserved.
Ahn, Jin Hwan; Bae, Tae Soo; Kang, Ki-Ser; Kang, Soo Yong; Lee, Sang Hak
2011-10-01
Longitudinal tears of the medial meniscus posterior horn (MMPH) are commonly associated with a chronic anterior cruciate ligament (ACL) deficiency. Many studies have demonstrated the importance of the medial meniscus in terms of limiting the amount of anterior-posterior tibial translation in response to anterior tibial loads in ACL-deficient knees. An MMPH tear in an ACL-deficient knee increases the anterior-posterior tibial translation and rotatory instability. In addition, MMPH repair will restore the tibial translation to the level before the tear. Controlled laboratory study. Ten human cadaveric knees were tested sequentially using a custom testing system under 5 conditions: intact, ACL deficient, ACL deficient with an MMPH peripheral longitudinal tear, ACL deficient with an MMPH repair, and ACL deficient with a total medial meniscectomy. The knee kinematics were measured at 0°, 15°, 30°, 60°, and 90° of flexion in response to a 134-N anterior and 200-N axial compressive tibial load. The rotatory kinematics were also measured at 15° and 30° of flexion in a combined rotatory load of 5 N·m of internal tibial torque and 10 N·m of valgus torque. Medial meniscus posterior horn longitudinal tears in ACL-deficient knees resulted in a significant increase in anterior-posterior tibial translation at all flexion angles except 90° (P < .05). An MMPH repair in an ACL-deficient knee showed a significant decrease in anterior-posterior tibial translation at all flexion angles except 60° compared with the ACL-deficient/MMPH tear state (P < .05). The total anterior-posterior translation of the ACL-deficient/MMPH repaired knee was not significantly increased compared with the ACL (only)-deficient knee but was increased compared with the ACL-intact knee (P > .05). A total medial meniscectomy in an ACL-deficient knee did not increase the anterior-posterior tibial translation significantly compared with MMPH tears in ACL-deficient knees at all flexion angles (P > .05). In a combined rotatory load, tibial rotation after MMPH tears or a total medial meniscectomy in an ACL-deficient knee were not affected significantly at all flexion angles. This study shows that an MMPH longitudinal tear in an ACL-deficient knee alters the knee kinematics, particularly the anterior-posterior tibial translation. MMPH repair significantly improved anterior-posterior tibial translation in ACL-deficient knees. These findings may help improve the treatment of patients with ACL and MMPH longitudinal tear by suggesting that the medial meniscal repairs should be performed for greater longevity when combined with an ACL reconstruction.
Effect of Knee Joint Angle and Contraction Intensity on Hamstrings Coactivation.
Wu, Rui; Delahunt, Eamonn; Ditroilo, Massimiliano; Lowery, Madeleine M; DE Vito, Giuseppe
2017-08-01
This study investigated the effect of knee joint angle and contraction intensity on the coactivation of the hamstring muscles (when acting as antagonists to the quadriceps) in young and older individuals of both sexes. A total of 25 young (24 ± 2.6 yr) and 26 older (70 ± 2.5 yr) healthy men and women participated. Maximal voluntary isometric contraction of the knee extensors and flexors was assessed at two knee joint angles (90° and 60°, 0° = full extension). At each angle, participants performed submaximal contractions of the knee extensors (20%, 50%, and 80% maximal voluntary isometric contraction), whereas surface EMG was simultaneously acquired from the vastus lateralis and biceps femoris muscles to assess the level (EMG root-mean-square) of agonist activation and antagonist coactivation. Subcutaneous adipose tissue in the areas corresponding to surface EMG electrode placements was measured via ultrasonography. The contractions performed at 90° knee flexion demonstrated higher levels of antagonist coactivation (all P < 0.01) and agonist activation (all P < 0.01) as a function of contraction intensity compared with the 60° knee flexion. Furthermore, after controlling for subcutaneous adipose tissue, older participants exhibited a higher level of antagonist coactivation at 60° knee flexion compared with young participants (P < 0.05). The results of the present study suggest that 1) the antagonist coactivation is dependent on knee joint angle and contraction intensity and 2) subcutaneous adipose tissue may affect the measured coactivation level likely because of a cross-talk effect. Antagonist coactivation may play a protective role in stabilizing the knee joint and maintaining constant motor output.
Biomechanical consequences of a nonanatomic posterior medial meniscal root repair.
LaPrade, Christopher M; Foad, Abdullah; Smith, Sean D; Turnbull, Travis Lee; Dornan, Grant J; Engebretsen, Lars; Wijdicks, Coen A; LaPrade, Robert F
2015-04-01
Posterior medial meniscal root tears have been reported to extrude with the meniscus becoming adhered posteromedially along the posterior capsule. While anatomic repair has been reported to restore tibiofemoral contact mechanics, it is unknown whether nonanatomic positioning of a meniscal root repair to a posteromedial location would restore the loading profile of the knee joint. The purpose of this study was to compare the tibiofemoral contact mechanics of a nonanatomic posterior medial meniscal tear with that of the intact knee or anatomic repair. It was hypothesized that a nonanatomic root repair would not restore the tibiofemoral contact pressures and areas to that of the intact or anatomic repair state. Controlled laboratory study. Tibiofemoral contact mechanics were recorded in 6 male human cadaveric knee specimens (average age, 45.8 years) using pressure sensors. Each knee underwent 5 testing conditions for the posterior medial meniscal root: (1) intact knee; (2) root tear; (3) anatomic transtibial pull-out repair; (4) nonanatomic transtibial pull-out repair, placed 5 mm posteromedially along the edge of the articular cartilage; and (5) root tear concomitant with an ACL tear. Knees were loaded with a 1000-N axial compressive force at 4 flexion angles (0°, 30°, 60°, 90°), and contact area, mean contact pressure, and peak contact pressure were calculated. Contact area was significantly lower after nonanatomic repair than for the intact knee at all flexion angles (mean = 44% reduction) and significantly higher for anatomic versus nonanatomic repair at all flexion angles (mean = 27% increase). At 0° and 90°, and when averaged across flexion angles, the nonanatomic repair significantly increased mean contact pressures in comparison to the intact knee or anatomic repair. When averaged across flexion angles, the peak contact pressures after nonanatomic repair were significantly higher than the intact knee but not the anatomic repair. In contrast, when averaged across all flexion angles, the anatomic repair resulted in a 17% reduction in contact area and corresponding increases in mean and peak contact pressures of 13% and 26%, respectively, compared with the intact knee. For most testing conditions, the nonanatomic repair did not restore the contact area or mean contact pressures to that of the intact knee or anatomic repair. However, the anatomic repair produced near-intact contact area and resulted in relatively minimal increases in mean and peak contact pressures compared with the intact knee. Results emphasize the importance of ensuring an anatomic posterior medial meniscal root repair by releasing the extruded menisci from adhesions and the posteromedial capsule. Similar caution toward preventing displacement of the meniscal root repair construct should be emphasized. © 2015 The Author(s).
The Effects of Fatigue and Local Carriage on Musculoskeletal Injury Mechanisms
2012-09-01
the mean and SD of the pelvis, hip, knee , and ankle angles at heel contact and stance of walking. Table 5 shows the mean and SD of the hip, knee , and...22.9 (8.6) Hip flexion at heel contact (deg) 32.1 (4.3) 28.2 (10.4) 45.4 (5.2) 40.6 (10.9) Knee flexion at heel contact (deg) -2.5 (3.1...1.1 (4.5) 3.9 (3.2) 4.7 (4.9) Maximum knee flexion at stance (deg) 19.0 (2.8) 20.7 (4.4) 24.6 (4.5) 25.0 (5.3) Ankle dorsi-flexion at heel
A study on muscle activity and ratio of the knee extensor depending on the types of squat exercise
Kang, Jeong-Il; Park, Joon-Su; Choi, Hyun; Jeong, Dae-Keun; Kwon, Hye-Min; Moon, Young-Jun
2017-01-01
[Purpose] For preventing the patellofemoral pain syndrome, this study aims to suggest a proper squat method, which presents selective muscle activity of Vastus Medialis Oblique and muscle activity ratios of Vastus Medialis Oblique/Vastus Lateralis by applying squat that is a representative weight bearing exercise method in various ways depending on the surface conditions and knee bending angles. [Subjects and Methods] An isometric squat that was accompanied by hip adduction, depending on the surface condition and the knee joint flexion angle, was performed by 24 healthy students. The muscle activity and the ratio of muscle activity were measured. [Results] In a comparison of muscle activity depending on the knee joint flexion angle on a weight-bearing surface, the vastus medialis oblique showed a significant difference at 15° and 60°. Meanwhile, in a comparison of the muscle activity ratio between the vastus medialis oblique and the vastus lateralis depending on the knee joint flexion angle on a weight-bearing surface, significant differences were observed at 15° and 60°. [Conclusion] An efficient squat exercise posture for preventing the patellofemoral pain syndrome is to increase the knee joint bending angle on a stable surface. But it would be efficient for patients with difficulties in bending the knee joint to keep a knee joint bending angle of 15 degrees or less on an unstable surface. It is considered that in future, diverse studies on selective Vastus Medialis Oblique strengthening exercise methods would be needed after applying them to patients with the patellofemoral pain syndrome. PMID:28210036
Cao, Wujing; Yu, Hongliu; Zhao, Weiliang; Li, Jin; Wei, Xiaodong
2018-01-01
Prosthetic knee is the most important component of lower limb prosthesis. Speed adaptive for prosthetic knee during swing flexion is the key method to realize physiological gait. This study aims to discuss the target of physiological gait, propose a speed adaptive control method during swing flexion and research the damping adjustment law of intelligent hydraulic prosthetic knee. According to the physiological gait trials of healthy people, the control target during swing flexion is defined. A new prosthetic knee with fuzzy logical control during swing flexion is designed to realize the damping adjustment automatically. The function simulation and evaluation system of intelligent knee prosthesis is provided. Speed adaptive control test of the intelligent prosthetic knee in different velocities are researched. The maximum swing flexion of the knee angle is set between sixty degree and seventy degree as the target of physiological gait. Preliminary experimental results demonstrate that the prosthetic knee with fuzzy logical control is able to realize physiological gait under different speeds. The faster the walking, the bigger the valve closure percentage of the hydraulic prosthetic knee. The proposed fuzzy logical control strategy and intelligent hydraulic prosthetic knee are effective for the amputee to achieve physiological gait.
NASA Astrophysics Data System (ADS)
Sewell, Tanzania S.; Piacsek, Kelly L.; Heckel, Beth A.; Sabol, John M.
2011-03-01
The current imaging standard for diagnosis and monitoring of knee osteoarthritis (OA) is projection radiography. However radiographs may be insensitive to markers of early disease such as osteophytes and joint space narrowing (JSN). Relative to standard radiography, digital X-ray tomosynthesis (DTS) may provide improved visualization of the markers of knee OA without the interference of superimposed anatomy. DTS utilizes a series of low-dose projection images over an arc of +/-20 degrees to reconstruct tomographic images parallel to the detector. We propose that DTS can increase accuracy and precision in JSN quantification. The geometric accuracy of DTS was characterized by quantifying joint space width (JSW) as a function of knee flexion and position using physical and anthropomorphic phantoms. Using a commercially available digital X-ray system, projection and DTS images were acquired for a Lucite rod phantom with known gaps at various source-object-distances, and angles of flexion. Gap width, representative of JSW, was measured using a validated algorithm. Over an object-to-detector-distance range of 5-21cm, a 3.0mm gap width was reproducibly measured in the DTS images, independent of magnification. A simulated 0.50mm (+/-0.13) JSN was quantified accurately (95% CI 0.44-0.56mm) in the DTS images. Angling the rods to represent knee flexion, the minimum gap could be precisely determined from the DTS images and was independent of flexion angle. JSN quantification using DTS was insensitive to distance from patient barrier and flexion angle. Potential exists for the optimization of DTS for accurate radiographic quantification of knee OA independent of patient positioning.
Quasi-stiffness of the knee joint in flexion and extension during the golf swing.
Choi, Ahnryul; Sim, Taeyong; Mun, Joung Hwan
2015-01-01
Biomechanical understanding of the knee joint during a golf swing is essential to improve performance and prevent injury. In this study, we quantified the flexion/extension angle and moment as the primary knee movement, and evaluated quasi-stiffness represented by moment-angle coupling in the knee joint. Eighteen skilled and 23 unskilled golfers participated in this study. Six infrared cameras and two force platforms were used to record a swing motion. The anatomical angle and moment were calculated from kinematic and kinetic models, and quasi-stiffness of the knee joint was determined as an instantaneous slope of moment-angle curves. The lead knee of the skilled group had decreased resistance duration compared with the unskilled group (P < 0.05), and the resistance duration of the lead knee was lower than that of the trail knee in the skilled group (P < 0.01). The lead knee of the skilled golfers had greater flexible excursion duration than the trail knee of the skilled golfers, and of both the lead and trail knees of the unskilled golfers. These results provide critical information for preventing knee injuries during a golf swing and developing rehabilitation strategies following surgery.
Welch, Tyler; Keller, Thomas; Maldonado, Ruben; Metzger, Melodie; Mohr, Karen; Kvitne, Ronald
2017-12-01
The natural history of posterior cruciate ligament (PCL) deficiency includes the development of arthrosis in the patellofemoral joint (PFJ). The purpose of this biomechanical study was to evaluate the hypothesis that dynamic bracing reduces PFJ pressures in PCL- and combined PCL/posterolateral corner (PLC)-deficient knees. Controlled Laboratory Study. Eight fresh frozen cadaveric knees with intact cruciate and collateral ligaments were included. PFJ pressures and force were measured using a pressure mapping system via a lateral arthrotomy at knee flexion angles of 30°, 60°, 90°, and 120° in intact, PCL-deficient, and PCL/PLC-deficient knees under a combined quadriceps/hamstrings load of 400 N/200 N. Testing was then repeated in PCL- and PCL/PLC-deficient knees after application of a dynamic PCL brace. Application of a dynamic PCL brace led to a reduction in peak PFJ pressures in PCL-deficient knees. In addition, the brace led to a significant reduction in peak pressures in PCL/PLC-deficient knees at 60°, 90°, and 120° of flexion. Application of the dynamic brace also led to a reduction in total PFJ force across all flexion angles for both PCL- and PCL/PLC-deficient knees. Dynamic bracing reduces PFJ pressures in PCL- and combined PCL/PLC-deficient knees, particularly at high degrees of knee flexion.
Kim, Sung-Jae; Chun, Yong-Min; Kim, Sung-Hwan; Moon, Hong-Kyo; Jang, Jae-Won
2013-07-01
The purpose of this study was to compare four graft-tunnel angles (GTA), the femoral GTA formed by three different femoral tunneling techniques (the outside-in, a modified inside-out technique in the posterior sag position with knee hyperflexion, and the conventional inside-out technique) and the tibia GTA in 3-dimensional (3D) knee flexion models, as well as to examine the influence of femoral tunneling techniques on the contact pressure between the intra-articular aperture of the femoral tunnel and the graft. Twelve cadaveric knees were tested. Computed tomography scans were performed at different knee flexion angles (0°, 45°, 90°, and 120°). Femoral and tibial GTAs were measured at different knee flexion angles on the 3D knee models. Using pressure sensitive films, stress on the graft of the angulation of the femoral tunnel aperture was measured in posterior cruciate ligament reconstructed cadaveric knees. Between 45° and 120° of knee flexion, there were no significant differences between the outside-in and modified inside-out techniques. However, the femoral GTA for the conventional inside-out technique was significantly less than that for the other two techniques (p<0.001). In cadaveric experiments using pressure-sensitive film, the maximum contact pressure for the modified inside-out and outside-in technique was significantly lower than that for the conventional inside-out technique (p=0.024 and p=0.017). The conventional inside-out technique results in a significantly lesser GTA and higher stress at the intra-articular aperture of the femoral tunnel than the outside-in technique. However, the results for the modified inside-out technique are similar to those for the outside-in technique.
Joint angles of the ankle, knee, and hip and loading conditions during split squats.
Schütz, Pascal; List, Renate; Zemp, Roland; Schellenberg, Florian; Taylor, William R; Lorenzetti, Silvio
2014-06-01
The aim of this study was to quantify how step length and the front tibia angle influence joint angles and loading conditions during the split squat exercise. Eleven subjects performed split squats with an additional load of 25% body weight applied using a barbell. Each subject's movements were recorded using a motion capture system, and the ground reaction force was measured under each foot. The joint angles and loading conditions were calculated using a cluster-based kinematic approach and inverse dynamics modeling respectively. Increases in the tibia angle resulted in a smaller range of motion (ROM) of the front knee and a larger ROM of the rear knee and hip. The external flexion moment in the front knee/hip and the external extension moment in the rear hip decreased as the tibia angle increased. The flexion moment in the rear knee increased as the tibia angle increased. The load distribution between the legs changed < 25% when split squat execution was varied. Our results describing the changes in joint angles and the resulting differences in the moments of the knee and hip will allow coaches and therapists to adapt the split squat exercise to the individual motion and load demands of athletes.
Meijer, Marrigje F; Velleman, Ton; Boerboom, Alexander L; Bulstra, Sjoerd K; Otten, Egbert; Stevens, Martin; Reininga, Inge H F
2016-01-01
The EOS stereoradiography system has shown to provide reliable varus/valgus (VV) measurements of the lower limb in 2D (VV2D) and 3D (VV3D) after total knee arthroplasty (TKA). Validity of these measurements has not been investigated yet, therefore the purpose of this study was to determine validity of EOS VV2D and VV3D. EOS images were made of a lower limb phantom containing a knee prosthesis, while varying VV angle from 15° varus to 15° valgus and flexion angle from 0° to 20°, and changing rotation from 20° internal to 20° external rotation. Differences between the actual VV position of the lower limb phantom and its position as measured on EOS 2D and 3D images were investigated. Rotation, flexion or VV angle alone had no major impact on VV2D or VV3D. Combination of VV angle and rotation with full extension did not show major differences in VV2D measurements either. Combination of flexion and rotation with a neutral VV angle showed variation of up to 7.4° for VV2D; maximum variation for VV3D was only 1.5°. A combination of the three variables showed an even greater distortion of VV2D, while VV3D stayed relatively constant. Maximum measurement difference between preset VV angle and VV2D was 9.8°, while the difference with VV3D was only 1.9°. The largest differences between the preset VV angle and VV2D were found when installing the leg in extreme angles, for example 15° valgus, 20° flexion and 20° internal rotation. After TKA, EOS VV3D were more valid than VV2D, indicating that 3D measurements compensate for malpositioning during acquisition. Caution is warranted when measuring VV angle on a conventional radiograph of a knee with a flexion contracture, varus or valgus angle and/or rotation of the knee joint during acquisition.
Ko, Seung-Nam
2017-01-01
Posterior cruciate ligament (PCL) reconstruction for patients with PCL insufficiency has been associated with postoperative improvements in proprioceptive function due to mechanoreceptor regeneration. However, it is unclear whether reconstructed PCL or contralateral normal knees have better proprioceptive function outcomes. This meta-analysis was designed to compare the proprioceptive function of reconstructed PCL or contralateral normal knees in patients with PCL insufficiency. All studies that compared proprioceptive function, as assessed with threshold to detect passive movement (TTDPM) or joint position sense (JPS) in PCL reconstructed or contralateral normal knees were included. JPS was calculated by reproducing passive positioning (RPP). Five studies met the inclusion/exclusion criteria for the meta-analysis. The proprioceptive function, defined as TTDPM (95% CI: 0.25 to 0.51°; P<0.00001) and RPP (95% CI: 0.19 to 0.45°; P<0.00001), was significantly different between the reconstructed PCL and contralateral normal knees. The mean difference in angle of error between the reconstructed PCL and contralateral normal knees was 0.06° greater in TTDPM than by RPP. In addition, results from subgroup analyses, based on the starting angles and the moving directions of the knee, that evaluated TTDPM at 15° flexion to 45° extension, TTDPM at 45° flexion to 110° flexion, RPP in flexion, and RPP in extension demonstrated that mean angles of error were significantly greater, by 0.38° (P = 0.0001), 0.36° (P = 0.02), 0.36° (P<0.00001), and 0.23° (P = 0.04), respectively, in reconstructed PCL than in contralateral normal knees. The proprioceptive function of PCL reconstructed knees was decreased, compared with contralateral normal knees, as determined by both TTDPM and RPP. In addition, the amount of loss of proprioception was greater in TTDPM than in RPP, even with minute differences. Results from subgroup analysis, that evaluated the mean angles of error in moving directions through RPP, suggested that the moving direction of flexion has a significantly greater mean for angles of error than the moving direction of extension. Although the level of differences between various parameters were statistically significant, further studies are needed to determine whether the small differences (>1°) of the loss of proprioception are clinically relevant. PMID:28922423
Wilderman, Danielle R; Ross, Scott E; Padua, Darin A
2009-01-01
Context: Improving neuromuscular control of hamstrings muscles might have implications for decreasing anterior cruciate ligament injuries in females. Objective: To examine the effects of a 6-week agility training program on quadriceps and hamstrings muscle activation, knee flexion angles, and peak vertical ground reaction force. Design: Prospective, randomized clinical research trial. Setting: Sports medicine research laboratory. Patients or Other Participants: Thirty female intramural basketball players with no history of knee injury (age = 21.07 ± 2.82 years, height = 171.27 ± 4.66 cm, mass = 66.36 ± 7.41 kg). Intervention(s): Participants were assigned to an agility training group or a control group that did not participate in agility training. Participants in the agility training group trained 4 times per week for 6 weeks. Main Outcome Measure(s): We used surface electromyography to assess muscle activation for the rectus femoris, vastus medialis oblique, medial hamstrings, and lateral hamstrings for 50 milliseconds before initial ground contact and while the foot was in contact with the ground during a side-step pivot maneuver. Knee flexion angles (at initial ground contact, maximum knee flexion, knee flexion displacement) and peak vertical ground reaction force also were assessed during this maneuver. Results: Participants in the training group increased medial hamstrings activation during ground contact after the 6-week agility training program. Both groups decreased their vastus medialis oblique muscle activation during ground contact. Knee flexion angles and peak vertical ground reaction force did not change for either group. Conclusions: Agility training improved medial hamstrings activity in female intramural basketball players during a side-step pivot maneuver. Agility training that improves hamstrings activity might have implications for reducing anterior cruciate ligament sprain injury associated with side-step pivots. PMID:19180214
Liu, Ping; Wang, Jianquan; Xu, Yan; Ao, Yingfang
2015-04-01
The aim of this study was to determine the in situ forces and length patterns of the fibular collateral ligament (FCL) and kinematics of the knee under various loading conditions. Six fresh-frozen cadaveric knees were used (mean age 46 ± 14.4 years; range 20-58). In situ forces and length patterns of FCL and kinematics of the knee were determined under the following loading conditions using a robotic/universal force-moment sensor testing system: no rotation, varus (10 Nm), external rotation (5 Nm), and internal rotation (5 Nm) at 0°, 15°, 30°, 60º, 90°, and 120° of flexion, respectively. Under no rotation loading, the distances between the centres of the FCL attachments decreased as the knee flexed. Under varus loading, the force in FCL peaked at 15° of flexion and decreased with further knee flexion, while distances remained nearly constant and the varus rotation increased with knee flexion. Using external rotation, the force in the FCL also peaked at 15° flexion and decreased with further knee flexion, the distances decreased with flexion, and external rotation increased with knee flexion. Using internal rotation load, the force in the FCL was relatively small across all knee flexion angles, and the distances decreased with flexion; the amount of internal rotation was fairly constant. FCL has a primary role in preventing varus and external rotation at 15° of flexion. The FCL does not perform isometrically following knee flexion during neutral rotation, and tibia rotation has significant effects on the kinematics of the FCL. Varus and external rotation laxity increased following knee flexion. By providing more realistic data about the function and length patterns of the FCL and the kinematics of the intact knee, improved reconstruction and rehabilitation protocols can be developed.
A mathematical model of forces in the knee under isometric quadriceps contractions.
Huss, R A; Holstein, H; O'Connor, J J
2000-02-01
To predict the knee's response to isometric quadriceps contractions against a fixed tibial restraint.Design. Mathematical modelling of the human knee joint. Isometric quadriceps contraction is commonly used for leg muscle strengthening following ligament injury or reconstruction. It is desirable to know the ligament forces induced but direct measurement is difficult. The model, previously applied to the Lachmann or 'drawer' tests, combines an extensible fibre-array representation of the cruciate ligaments with a compressible 'thin-layer' representation of the cartilage. The model allows the knee configuration and force system to be calculated, given flexion angle, restraint position and loading. Inclusion of cartilage deformation increases relative tibio-femoral translation and decreases the ligament forces generated. For each restraint position, a range of flexion angles is found in which no ligament force is required, as opposed to a single flexion angle in the case of incompressible cartilage layers. Knee geometry and ligament elasticity are found to be the most important factors governing the joint's response to isometric quadriceps contractions, but cartilage deformation is found to be more important than in the Lachmann test. Estimation of knee ligament forces is important when devising exercise regimes following ligament injury or reconstruction. The finding of a 'neutral zone' of zero ligament force may have implications for rehabilitation of the ligament-injured knee.
Smith, Rose; Ford, Kevin R; Myer, Gregory D; Holleran, Adam; Treadway, Erin; Hewett, Timothy E
2007-01-01
Context: The recent increase in women's varsity soccer participation has been accompanied by a lower extremity injury rate that is 2 to 6 times that of their male counterparts. Objective: To define the differences between lower extremity biomechanics (knee abduction and knee flexion measures) and performance (maximal vertical jump height) between National Collegiate Athletic Association Division I and III female soccer athletes during a drop vertical jump. Design: Mixed 2 × 2 design. Setting: Research laboratory. Patients or Other Participants: Thirty-four female collegiate soccer players (Division I: n = 19; Division III: n = 15) participated in the study. The groups were similar in height and mass. Intervention(s): Each subject performed a maximal vertical jump, followed by 3 drop vertical jumps. Main Outcome Measure(s): Kinematics (knee abduction and flexion angles) and kinetics (knee abduction and flexion moments) were measured with a motion analysis system and 2 force platforms during the drop vertical jumps. Results: Knee abduction angular range of motion and knee abduction external moments were not different between groups (P > .05). However, Division I athletes demonstrated decreased knee flexion range of motion (P = .038) and greater peak external knee flexion moment (P = .009) compared with Division III athletes. Division I athletes demonstrated increased vertical jump height compared with Division III (P = .008). Conclusions: Division I athletes demonstrated different sagittal-plane mechanics than Division III athletes, which may facilitate improved performance. The similarities in anterior cruciate ligament injury risk factors (knee abduction torques and angles) may correlate with the consistent incidence of anterior cruciate ligament injury across divisions. PMID:18174935
Effect of Human Movement on Galvanic Intra-Body Communication during Single Gait Cycle
NASA Astrophysics Data System (ADS)
Ibrahim, I. W.; Razak, A. H. A.; Ahmad, A.; Salleh, M. K. M.
2015-11-01
Intra-body communication (IBC) is a communication system that uses human body as a signal transmission medium. From previous research, two coupling methods of IBC were concluded which are capacitive coupling and galvanic coupling. This paper investigates the effect of human movement on IBC using the galvanic coupling method. Because the human movement is control by the limb joint, the knee flexion angle during gait cycle was used to examine the influence of human movement on galvanic coupling IBC. The gait cycle is a cycle of people walking that start from one foot touch the ground till that foot touch the ground again. Frequency range from 300 kHz to 200MHz was swept in order to investigate the signal transmission loss and the result was focused on operating frequency 70MHz to 90MHz. Results show that the transmission loss varies when the knee flexion angle increased. The highest loss of signal at frequency range between 70MHz to 90 MHz was 69dB when the knee flexion angle is 50° and the minimum loss was 51dB during the flexion angle is 5°.
Yoshihara, Yasushi; Arai, Yuji; Nakagawa, Shuji; Inoue, Hiroaki; Ueshima, Keiichiro; Fujiwara, Hiroyoshi; Oda, Ryo; Taniguchi, Daigo; Kubo, Toshikazu
2016-08-01
Favourable long-term results after total knee arthroplasty (TKA) require appropriate soft tissue balance. However, the relationships between long-term results after TKA surgery and mediolateral laxities at extension and at 90° flexion remain unknown. This study therefore quantitatively assessed ligament balance at extension and at 90° knee flexion at least 10 years after primary TKA, as well as clarifying the relationships between long-term outcomes and mediolateral laxities. This study included 49 knees (19 CR type and 30 PS type) of 33 patients followed up for at least 10 years after TKA at our hospital. Plain radiographs were obtained with about 150 N of varus or valgus stress using a Telos arthrometer at extension. At 90° flexion, epicondylar views were obtained under a 1.5-kg load and with about 10 kg of varus or valgus stress. Lateral laxity of about 5° was observed in both extension and flexion, with total laxities of varus and valgus stress each less than 10°. Postoperative clinical outcomes were good, with significant improvements in extension angle, femorotibial angle, and KSS, and no loosening in any knee. Good long-term results of TKA can be obtained with a lateral laxity of about 5°, equivalent to that of healthy knees. III.
Combined Effects of Fatigue and Surface Instability on Jump Biomechanics in Elite Athletes.
Prieske, Olaf; Demps, Marie; Lesinski, Melanie; Granacher, Urs
2017-09-01
The present study aimed to examine the effects of fatigue and surface instability on kinetic and kinematic jump performance measures. Ten female and 10 male elite volleyball players (18±2 years) performed repetitive vertical double-leg box jumps until failure. Pre and post fatigue, jump height/performance index, ground reaction force and knee flexion/valgus angles were assessed during drop and countermovement jumps on stable and unstable surfaces. Fatigue, surface condition, and sex resulted in significantly lower drop jump performance and ground reaction force (p≤0.031, 1.1≤d≤3.5). Additionally, drop jump knee flexion angles were significantly lower following fatigue (p=0.006, d=1.5). A significant fatigue×surface×sex interaction (p=0.020, d=1.2) revealed fatigue-related decrements in drop jump peak knee flexion angles under unstable conditions and in men only. Knee valgus angles were higher on unstable compared to stable surfaces during drop jumps and in females compared to males during drop and countermovement jumps (p≤0.054, 1.0≤d≤1.1). Significant surface×sex interactions during countermovement jumps (p=0.002, d=1.9) indicated that knee valgus angles at onset of ground contact were significantly lower on unstable compared to stable surfaces in males but higher in females. Our findings revealed that fatigue and surface instability resulted in sex-specific knee motion strategies during jumping in elite volleyball players. © Georg Thieme Verlag KG Stuttgart · New York.
Lorenzetti, Silvio; Gülay, Turgut; Stoop, Mirjam; List, Renate; Gerber, Hans; Schellenberg, Florian; Stüssi, Edgar
2012-10-01
The aim of this study was to compare the angles and corresponding moments in the knee and hip during squats. Twenty subjects performed restricted and unrestricted squats with barbell loads that were 0, ¼, and ½ their body weight. The experimental setup consisted of a motion capture system and 2 force plates. The moments were calculated using inverse dynamics. During the unrestricted squats, the maximum moments in the knee were significantly higher, and those in the hip were significantly lower than during restricted squats. At the lowest position, the maximum knee flexion angles were approximately 86° for the restricted and approximately 106° for the unrestricted techniques, whereas the maximum hip flexion angle was between 95° and 100°. The higher moments in the hip during restricted squats suggest a higher load of the lower back. Athletes who aim to strengthen their quadriceps should consider unrestricted squats because of the larger knee load and smaller back load.
Variability of Plyometric and Ballistic Exercise Technique Maintains Jump Performance.
Chandler, Phillip T; Greig, Matthew; Comfort, Paul; McMahon, John J
2018-06-01
Chandler, PT, Greig, M, Comfort, P, and McMahon, JJ. Variability of plyometric and ballistic exercise technique maintains jump performance. J Strength Cond Res 32(6): 1571-1582, 2018-The aim of this study was to investigate changes in vertical jump technique over the course of a training session. Twelve plyometric and ballistic exercise-trained male athletes (age = 23.4 ± 4.6 years, body mass = 78.7 ± 18.8 kg, height = 177.1 ± 9.0 cm) performed 3 sets of 10 repetitions of drop jump (DJ), rebound jump (RJ) and squat jump (SJ). Each exercise was analyzed from touchdown to peak joint flexion and peak joint flexion to take-off. Squat jump was analyzed from peak joint flexion to take-off only. Jump height, flexion and extension time and range of motion, and instantaneous angles of the ankle, knee, and hip joints were measured. Separate 1-way repeated analyses of variance compared vertical jump technique across exercise sets and repetitions. Exercise set analysis found that SJ had lower results than DJ and RJ for the angle at peak joint flexion for the hip, knee, and ankle joints and take-off angle of the hip joint. Exercise repetition analysis found that the ankle joint had variable differences for the angle at take-off, flexion, and extension time for RJ. The knee joint had variable differences for flexion time for DJ and angle at take-off and touchdown for RJ. There was no difference in jump height. Variation in measured parameters across repetitions highlights variable technique across plyometric and ballistic exercises. This did not affect jump performance, but likely maintained jump performance by overcoming constraints (e.g., level of rate coding).
Joint angle affects volitional and magnetically-evoked neuromuscular performance differentially.
Minshull, C; Rees, D; Gleeson, N P
2011-08-01
This study examined the volitional and magnetically-evoked neuromuscular performance of the quadriceps femoris at functional knee joint angles adjacent to full extension. Indices of volitional and magnetically-evoked neuromuscular performance (N=15 healthy males, 23.5 ± 2.9 years, 71.5 ± 5.4 kg, 176.5 ± 5.5 cm) were obtained at 25°, 35° and 45° of knee flexion. Results showed that volitional and magnetically-evoked peak force (PF(V) and P(T)F(E), respectively) and electromechanical delay (EMD(V) and EMD(E), respectively) were enhanced by increased knee flexion. However, greater relative improvements in volitional compared to evoked indices of neuromuscular performance were observed with increasing flexion from 25° to 45° (e.g. EMD(V), EMD(E): 36% vs. 11% improvement, respectively; F([2,14])=6.8, p<0.05). There were no significant correlations between EMD(V) and EMD(E) or PF(V) and P(T)F(E), at analogous joint positions. These findings suggest that the extent of the relative differential between volitional and evoked neuromuscular performance capabilities is joint angle-specific and not correlated with performance capabilities at adjacent angles, but tends to be smaller with increased flexion. As such, effective prediction of volitional from evoked performance capabilities at both analogous and adjacent knee joint positions would lack robustness. Copyright © 2011 Elsevier Ltd. All rights reserved.
A flexible wearable sensor for knee flexion assessment during gait.
Papi, Enrica; Bo, Yen Nee; McGregor, Alison H
2018-05-01
Gait analysis plays an important role in the diagnosis and management of patients with movement disorders but it is usually performed within a laboratory. Recently interest has shifted towards the possibility of conducting gait assessments in everyday environments thus facilitating long-term monitoring. This is possible by using wearable technologies rather than laboratory based equipment. This study aims to validate a novel wearable sensor system's ability to measure peak knee sagittal angles during gait. The proposed system comprises a flexible conductive polymer unit interfaced with a wireless acquisition node attached over the knee on a pair of leggings. Sixteen healthy volunteers participated to two gait assessments on separate occasions. Data was simultaneously collected from the novel sensor and a gold standard 10 camera motion capture system. The relationship between sensor signal and reference knee flexion angles was defined for each subject to allow the transformation of sensor voltage outputs to angular measures (degrees). The knee peak flexion angle from the sensor and reference system were compared by means of root mean square error (RMSE), absolute error, Bland-Altman plots and intra-class correlation coefficients (ICCs) to assess test-retest reliability. Comparisons of knee peak flexion angles calculated from the sensor and gold standard yielded an absolute error of 0.35(±2.9°) and RMSE of 1.2(±0.4)°. Good agreement was found between the two systems with the majority of data lying within the limits of agreement. The sensor demonstrated high test-retest reliability (ICCs>0.8). These results show the ability of the sensor to monitor knee peak sagittal angles with small margins of error and in agreement with the gold standard system. The sensor has potential to be used in clinical settings as a discreet, unobtrusive wearable device allowing for long-term gait analysis. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Knee Joint Kinematics and Kinetics During a Lateral False-Step Maneuver
Golden, Grace M.; Pavol, Michael J.; Hoffman, Mark A.
2009-01-01
Abstract Context: Cutting maneuvers have been implicated as a mechanism of noncontact anterior cruciate ligament (ACL) injuries in collegiate female basketball players. Objective: To investigate knee kinematics and kinetics during running when the width of a single step, relative to the path of travel, was manipulated, a lateral false-step maneuver. Design: Crossover design. Setting: University biomechanics laboratory. Patients or Other Participants: Thirteen female collegiate basketball athletes (age = 19.7 ± 1.1 years, height = 172.3 ± 8.3 cm, mass = 71.8 ± 8.7 kg). Intervention(s): Three conditions: normal straight-ahead running, lateral false step of width 20% of body height, and lateral false step of width 35% of body height. Main Outcome Measure(s): Peak angles and internal moments for knee flexion, extension, abduction, adduction, internal rotation, and external rotation. Results: Differences were noted among conditions in peak knee angles (flexion [P < .01], extension [P = .02], abduction [P < .01], and internal rotation [P < .01]) and peak internal knee moments (abduction [P < .01], adduction [P < .01], and internal rotation [P = .03]). The lateral false step of width 35% of body height was associated with larger peak flexion, abduction, and internal rotation angles and larger peak abduction, adduction, and internal rotation moments than normal running. Peak flexion and internal rotation angles were also larger for the lateral false step of width 20% of body height than for normal running, whereas peak extension angle was smaller. Peak internal rotation angle increased progressively with increasing step width. Conclusions: Performing a lateral false-step maneuver resulted in changes in knee kinematics and kinetics compared with normal running. The differences observed for lateral false steps were consistent with proposed mechanisms of ACL loading, suggesting that lateral false steps represent a hitherto neglected mechanism of noncontact ACL injury. PMID:19771289
The Lower Extremity Biomechanics of Single- and Double-Leg Stop-Jump Tasks
2011-01-01
The anterior cruciate ligament (ACL) injury is a common occurrence in sports requiring stop-jump tasks. Single- and double-leg stop-jump techniques are frequently executed in sports. The higher risk of ACL injury in single-leg drop landing task compared to a double-leg drop landing task has been identified. However the injury bias between single- and double-leg landing techniques has not been investigated for stop-jump tasks. The purpose of this study was to determine the differences between single- and double-leg stop-jump tasks in knee kinetics that were influenced by the lower extremity kinematics during the landing phase. Ground reaction force, lower extremity kinematics, and knee kinetics data during the landing phase were obtained from 10 subjects performing single- and double-leg stop-jump tasks, using motion-capture system and force palates. Greater peak posterior and vertical ground reaction forces, and peak proximal tibia anterior and lateral shear forces (p < 0.05) during landing phase were observed of single-leg stop-jump. Single-leg stop-jump exhibited smaller hip and knee flexion angle, and knee flexion angular velocity at initial foot contact with the ground (p < 0.05). We found smaller peak hip and knee flexion angles (p < 0.05) during the landing phase of single-leg stop-jump. These results indicate that single-leg landing may have higher ACL injury risk than double-leg landing in stop-jump tasks that may be influenced by the lower extremity kinematics during the landing phase. Key points Non-contact ACL injuries are more likely to occur during the single-leg stop-jump task than during the double-leg stop-jump task. Single-leg stop-jump exhibited greater peak proximal tibia anterior and lateral shear forces, and peak posterior and vertical ground reaction forces during the landing phase than the double-leg stop-jump task. Single-leg stop-jump exhibited smaller hip flexion angle, knee flexion angle, and knee flexion angular velocity at initial foot contact with the ground. Single-leg stop-jump exhibited greater peak knee extension and valgus moment during the landing phase than the double-leg stop-jump task. Single-leg stop-jump extended the hip joint at initial foot contact with the ground. PMID:24149308
LaPrade, Robert F; Smith, Sean D; Wilson, Katharine J; Wijdicks, Coen A
2015-10-01
Counteracting posterior translation of the tibia with an anterior force on the posterior proximal tibia has been demonstrated clinically to improve posterior knee laxity following posterior cruciate ligament (PCL) injury. This study quantified forces applied to the posterior proximal tibia by two knee braces designed for treatment of PCL injuries. The forces applied by two knee braces to the posterior proximal tibia and in vivo three-dimensional knee kinematics of six adult, male, healthy volunteer subjects (mean ± standard deviation: height, 182.5 ± 5.2 cm; body mass, 83.2 ± 9.3 kg; body mass index, 24.9 ± 1.5 kg/m(2); age, 25.8 ± 2.9 years) were measured using a custom pressure mapping technique and traditional surface marker motion capture techniques, while subjects performed three functional activities. The activities included seated unloaded knee flexion, squatting, and stair descent in a new generation dynamic force (DF) PCL brace and a static force (SF) PCL brace. During unloaded flexion at the lowest force level setting, the force applied by the DF brace increased as a function of flexion angle (slope = 0.7 N/°; p < 0.001) compared to the SF brace effect. Force applied by the SF brace did not significantly change as a function of flexion angle (slope = 0.0 N/°; n.s.). By 45° of flexion, the average force applied by the DF brace (48.1 N) was significantly larger (p < 0.001) than the average force applied by the SF brace (25.0 N). The difference in force continued to increase as flexion angle increased. During stair descent, average force (mean ± standard deviation) at toe off was significantly higher (p = 0.013) for the DF brace (78.7 ± 21.6 N) than the SF brace (37.3 ± 7.2 N). Similar trends were observed for squatting and for the higher force level settings. The DF brace applied forces to the posterior proximal tibia that dynamically increased with increased flexion angle. Additionally, the DF brace applied significantly larger forces at higher flexion angles compared to the SF brace where the PCL is known to experience larger in situ forces. Clinical studies are necessary to determine whether the loading characteristics of the DF brace, which more closely replicated the in situ loading profile of the native PCL, results in long-term improved posterior knee laxity following PCL injury. II.
Knee Biomechanics During Jogging After Arthroscopic Partial Meniscectomy: A Longitudinal Study.
Hall, Michelle; Wrigley, Tim V; Metcalf, Ben R; Hinman, Rana S; Cicuttini, Flavia M; Dempsey, Alasdair R; Lloyd, David G; Bennell, Kim L
2017-07-01
Altered knee joint biomechanics is thought to play a role in the pathogenesis of knee osteoarthritis and has been reported in patients after arthroscopic partial meniscectomy (APM) while performing various activities. Longitudinally, understanding knee joint biomechanics during jogging may assist future studies to assess the implications of jogging on knee joint health in this population. To investigate knee joint biomechanics during jogging in patients 3 months after APM and a healthy control group at baseline and 2 years later at follow-up. Controlled laboratory study. Seventy-eight patients who underwent medial APM and 38 healthy controls underwent a 3-dimensional motion analysis during barefoot overground jogging at baseline. Sixty-four patients who underwent APM and 23 controls returned at follow-up. External peak moments (flexion and adduction) and the peak knee flexion angle during stance were evaluated for the APM leg, non-APM leg (nonoperated leg), and control leg. At baseline, the peak knee flexion angle was 1.4° lower in the APM leg compared with the non-APM leg ( P = .03). No differences were found between the moments in the APM leg compared with the control leg (all P > .05). However, the normalized peak knee adduction moment was 35% higher in the non-APM leg compared with the control leg ( P = .008). In the non-APM leg, the normalized peak knee adduction and flexion moments were higher compared with the APM leg by 16% and 10%, respectively, at baseline ( P ≤ .004). Despite the increase in the peak knee flexion moment in the APM leg compared with the non-APM leg ( P < .001), there were no differences in the peak knee flexion moment or any other parameter assessed at 2-year follow-up between the legs ( P > .05). Comparing the APM leg and control leg, no differences in knee joint biomechanics during jogging for the variables assessed were observed. Higher knee moments in the non-APM leg may have clinical implications for the noninvolved leg. Kinematic differences were small (~1.4°) and therefore of questionable clinical relevance. These results may facilitate future clinical research regarding the implications of jogging on knee joint health in middle-aged, overweight patients after APM.
Hackney, James; Brummel, Sara; Newman, Mary; Scott, Shannon; Reinagel, Matthew; Smith, Jennifer
2015-09-01
We carried out a study to investigate how low stiffness flooring may help prevent overuse injuries of the lower extremity in dancers. It was hypothesized that performing a ballet jump (sauté) on a reduced stiffness dance floor would decrease maximum joint flexion angles and negative angular velocities at the hips, knees, or ankles compared to performing the same jump on a harder floor. The participants were 15 young adult female dancers (age range 18 to 28, mean = 20.89 ± 2.93 years) with at least 5 years of continuous ballet experience and without history of serious lower body injury, surgery, or recent pain. They performed sautés on a (low stiffness) Harlequin ® WoodSpring Floor and on a vinyl-covered hardwood on concrete floor. Maximum joint flexion angles and negative velocities at bilateral hips, knees, and ankles were measured with the "Ariel Performance Analysis System" (APAS). Paired one-tailed t-tests yielded significant decreases in maximum knee angle (average decrease = 3.4° ± 4.2°, p = 0.026) and angular negative velocity of the ankles (average decrease = 18.7°/sec ± 27.9°/sec, p = 0.009) with low stiffness flooring. If the knee angle is less acute, then the length of the external knee flexion moment arm will also be shorter and result in a smaller external knee flexion moment, given an equal landing force. Also, high velocities of eccentric muscle contraction, which are necessary to control negative angular velocity of the ankle joint, are associated with higher risk of musculotendinous injury. Hence, our findings indicate that reduced floor stiffness may indeed help decrease the likelihood of lower extremity injuries.
Liao, Chun-De; Huang, Yi-Ching; Lin, Li-Fong; Chiu, Yen-Shuo; Tsai, Jui-Chen; Chen, Chun-Lung; Liou, Tsan-Hon
2016-08-01
This study evaluated the effects of continuous passive motion (CPM) on accelerated flexion after total knee arthroplasty (TKA) and whether CPM application measures (i.e. initial angle and daily increment) are associated with functional outcomes. A retrospective investigation was conducted at the rehabilitation centre of a university-based teaching hospital. Patients who received CPM therapy immediately after TKA surgery were categorized into rapid-, normal-, and slow-progress groups according to their response to CPM during their acute inpatient stay. Knee pain, passive knee flexion, and knee function-measured using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC)-were assessed preoperatively at discharge and at 3- and 6-month outpatient follow-up visits. A total of 354 patients were followed for 6 months after inpatient-stay discharge. The patients in the rapid-progress group (n = 119) exhibited significantly greater knee flexions than those in the slow-progress group did (n = 103) at the 3-month follow-up [mean difference (MD) = 10.3°, 95 % confidence interval (CI) 4.3°-16.3°, p < 0.001] and 6-month follow-up (MD = 10.9°, 95 % CI 6.3°-15.6°, p < 0.001). Significant WOMAC score differences between the rapid- and slow-progress groups were observed at the 3-month follow-up (MD = 7.2, 95 % CI 5.4-9.1, p < 0.001) and 6-month follow-up (MD = 16.1, 95 % CI 13.4-18.7, p < 0.001). CPM initial angles and rapid progress significantly predicted short- and long-term outcomes in knee flexion and WOMAC scores (p < 0.001). When CPM is used, early application with initial high flexion and rapid progress benefits knee function up to 6 months after TKA. II.
Does patella position influence ligament balancing in total knee arthroplasty?
Yoon, Jung-Ro; Oh, Kwang-Jun; Wang, Joon Ho; Yang, Jae-Hyuk
2015-07-01
In vivo comparative gap measurements were performed in three different patella positions (reduced, subluxated and everted) using offset-type-force-controlled-spreader-system. Prospectively, 50 knees were operated by total knee arthroplasty using a navigation-assisted gap-balancing technique. The offset-type-force-controlled-spreader-system was used for gap measurements. This commercially available instrument allows controllable tension in patella-reduced position. The mediolateral gaps of knee extension (0°) and flexion (90°) angle were recorded in three different patella positions; reduced, subluxated and everted. Any gap differences of more than 3 mm were considered as a meaningful difference. Correlation between the difference with the demographic data, preoperative radiologic alignment and intraoperative data was analysed. For statistical analysis, ANOVA and Pearson's correlation test were used. The gaps in patella eversion demonstrated smaller gaps both in knee extension and flexion position compared to the gaps of patella reduction position. The amount of decreased gaps was more definite in knee flexion position. Statistically significant difference was observed for the lateral gap of patella eversion compared to gap of patella reduction in knee flexion position (p < 0.05). There were notable cases of variability in knee flexion position. Significant portion of 12 (24 %) knees of patella subluxation and 33 (66 %) knees of patella evertion demonstrated either increased or decreased gaps in knee flexion position compared to the gaps of patella reduction position. The gaps in patella eversion demonstrated smaller gaps both in knee extension and flexion position compared to the gaps of patella reduction position. The amount of decreased gaps was more definite in knee flexion position. Therefore, the intraoperative patellar positioning has influence on the measurement of the joint gap. Keeping the patella in reduced position is important during gap balancing. I.
Uğur, Levent
2017-12-01
Having a complicated anatomy, the knee joint has been further detailed and a new formation defined, the anterolateral ligament (ALL), in recent studies. While the importance of this ligament, which previously was associated with Segond fractures, was explained via clinical, radiologic and biomechanical studies, and basically, is thought to be a fixator structures for the tibia against internal rotation stress. Although in recent studies efficient surgical treatment was applied to patients who underwent anterior cruciate ligament (ACL) operation, some patients having a positive pivot test highlights the clinical importance of the ALL. The aim of this study is to evaluate reaction forces of different flexion angles on the tibia during internal rotation and anterior drawer tests on both the ALL and ACL, and to examine theimportance of this ligament in knee biomechanics by a finite element analysis method. In this study, normal anatomy knee joint was modelled using Computed Tomography images from lower extremity length in DICOM format. 0°, 15°,30°,45°,60°,75° and 90° angles of flexion were applied, respectively, to these models and reaction force vectors formed on both ligaments were examined separately and as total vector and size by applying internal rotation and anterior drawer forces on each model. Non-linear analysis was conducted using ANSYS (version 17) with the same limit conditions applied to all models. After all models were examined, in general when comparing reaction forces, those on the ACL were found to be higher. However, when vectoral directions were examined, forces on ALL increased with increased flexion ratio and internal rotation momentum. Beyond 30° flexion, the tensile force on the ALL is increased and compressive overload on the ACL occurs. The ALL plays an important role in stability, especially against internal rotation forces, and an increased knee joint flexion ratio increases the stability contribution ratio. In particular, at 30° and higher angles, ACL reflects an antagonist effect and contributes to knee joint stability for rotational and mediolateral transposition. Copyright © 2017 John Wiley & Sons, Ltd.
Mid-term Results of Total Knee Arthroplasty Using PFC Sigma RP-F.
Kim, Jun-Young; Cheon, Sang-Ho; Kyung, Hee-Soo
2012-12-01
We compared the mid-term results after total knee arthroplasty (TKA) using PFC Sigma RP-F mobile model with PFC Sigma PS fixed model. We analyzed 45 knees that underwent TKA with PFC Sigma RP-Fn (study group) and 45 knees with PFC Sigma PS (control group). The mean follow-up period was 65 months (range, 60-69 months). The evaluation system of the American knee society was used for clinical and radiological assessment. Also, the maximal knee flexion angle was assessed. The mean maximum flexion angle in the study group (135°) was greater than that in the control group (125°) at the early post-operation & final follow-up period (p=0.033). The range of motion (ROM) in the study group was recovered earlier at the postoperative 6 months, and ROM gain was improved to a greater extent at the final follow-up period (p=0.039). The knee score and function score and radiographic evaluation were no difference between the two groups (p>0.05) at the final follow-up. The two cases of radiolucency in posterior condyle and medial tibial plateau and one case of patellar elongation were seen in the study group. The PFC Sigma RP-F mobile system appears to facilitate greater maximum flexion angle and ROM gain with two cases of radiolucent line.
Gaudreault, Nathaly; Mezghani, Neila; Turcot, Katia; Hagemeister, Nicola; Boivin, Karine; de Guise, Jacques A
2011-03-01
Interpreting gait data is challenging due to intersubject variability observed in the gait pattern of both normal and pathological populations. The objective of this study was to investigate the impact of using principal component analysis for grouping knee osteoarthritis (OA) patients' gait data in more homogeneous groups when studying the effect of a physiotherapy treatment. Three-dimensional (3D) knee kinematic and kinetic data were recorded during the gait of 29 participants diagnosed with knee OA before and after they received 12 weeks of physiotherapy treatment. Principal component analysis was applied to extract groups of knee flexion/extension, adduction/abduction and internal/external rotation angle and moment data. The treatment's effect on parameters of interest was assessed using paired t-tests performed before and after grouping the knee kinematic data. Increased quadriceps and hamstring strength was observed following treatment (P<0.05). Except for the knee flexion/extension angle, two different groups (G(1) and G(2)) were extracted from the angle and moment data. When pre- and post-treatment analyses were performed considering the groups, participants exhibiting a G(2) knee moment pattern demonstrated a greater first peak flexion moment, lower adduction moment impulse and smaller rotation angle range post-treatment (P<0.05). When pre- and post-treatment comparisons were performed without grouping, the data showed no treatment effect. The results of the present study suggest that the effect of physiotherapy on gait mechanics of knee osteoarthritis patients may be masked or underestimated if kinematic data are not separated into more homogeneous groups when performing pre- and post-treatment comparisons. Copyright © 2010 Elsevier Ltd. All rights reserved.
Sosdian, L; Dobson, F; Wrigley, T V; Paterson, K; Bennell, K; Dowsey, M; Choong, P; Allison, K; Hinman, R S
2014-12-01
Knee arthroplasty (KA) is recognized as an effective treatment of knee joint osteoarthritis and up to 90% of patients experience substantial pain relief. There has been no systematic review synthesizing the longitudinal changes in gait following KA. The aims of this systematic review were to determine the effects of KA on (i) frontal plane and (ii) sagittal plane kinematic and kinetic parameters during the stance phase of gait. MEDLINE (PubMed), CINAHL, SPORTdiscus (EBSCO), and Cochrane Library (Wiley) were searched until April 10th, 2014. 1,765 articles were identified, of which 19 studies describing 3-dimensional gait analysis pre- and post-KA were included. Study quality was evaluated by two reviewers independently using the Downs and Black checklist. Following KA, in the frontal plane, the maximum knee adduction angle and external knee adduction moment (KAM) tended to decrease. In the sagittal plane, findings suggest that the maximum knee flexion moment is increased. From the ten studies that included a healthy reference group, it was unclear whether gait variables returned to normal following KA. Overall, it appears that KA results in a decreased peak KAM and maximum knee adduction angles, an increased peak knee flexion moment and inconsistent changes in the peak knee flexion angle. Knowledge gaps remain due to methodological inconsistencies across studies, limited statistical analysis, and largely heterogeneous sample populations. More research is needed to determine whether KA restores gait patterns to normal, or if additional rehabilitation may be needed to optimize gait following surgery for osteoarthritis. Copyright © 2014 Elsevier B.V. All rights reserved.
Athwal, Kiron K; Daou, Hadi El; Kittl, Christoph; Davies, Andrew J; Deehan, David J; Amis, Andrew A
2016-08-01
The aim of this study was to quantify the contributions of medial soft tissues to stability following cruciate-retaining (CR) or posterior-stabilised (PS) total knee arthroplasty (TKA). Using a robotic system, eight cadaveric knees were subjected to ±90-N anterior-posterior force, ±5-Nm internal-external and ±8-Nm varus-valgus torques at various flexion angles. The knees were tested intact and then with CR and PS implants, and successive cuts of the deep and superficial medial collateral ligaments (dMCL, sMCL) and posteromedial capsule (PMC) quantified the percentage contributions of each structure to restraining the applied loads. In implanted knees, the sMCL restrained valgus rotation (62 % across flexion angles), anterior-posterior drawer (24 and 10 %, respectively) and internal-external rotation (22 and 37 %). Changing from CR TKA to PS TKA increased the load on the sMCL when resisting valgus loads. The dMCL restrained 11 % of external and 13 % of valgus rotations, and the PMC was significant at low flexion angles. This work has shown that medial release in the varus knee should be minimised, as it may inadvertently result in a combined laxity pattern. There is increasing interest in preserving constitutional varus in TKA, and this work argues for preservation of the sMCL to afford the surgeon consistent restraint and maintain a balanced knee for the patient.
Wallace, B J; Kernozek, T W; Bothwell, E C
2007-12-01
Females experience at least twice as many non-contact anterior cruciate ligament (ACL) injuries as males. The aim of this study was to investigate if males and females exhibited different characteristics while performing a modified pro-agility test. Collegiate Division III male baseball (n=14) and female softball (n=13) players performed 4 trials of a modified pro-agility task, which consisted of running toward a force platform target for 5 steps, planting their right foot, and propelling themselves off of the target with their left foot. Kinematic and kinetic parameters were compared using a multivariate analysis of variance between gender with the level of significance set at P<0.05. Males and females exhibited similar knee valgus angles. Females had a greater maximum knee extension angle (10.14 degrees vs 17.43 degrees ), and greater knee range of motion (46.12 degrees vs 40.12 degrees ). Both groups reached maximum knee flexion at 52% of stance. Females had significantly more maximum hip flexion than males (28.86 degrees vs 22.75 degrees ). Females had significantly smaller minimum internal knee varus moments than their male counterparts (1.12 Nm/kg vs 1.55 Nm/kg). Vertical ground reaction forces as a percentage of bodyweight, and stance time, were not statistically different. The female group displayed an external knee rotation angle (2.49 degrees ) during the beginning of their stance, which was significantly different than the internal rotation angle (4.11 degrees ) in the male group. Early in stance knee rotation angle was highly correlated with the lack of internal knee varus moment (males R(2)=0.75, females R(2)=0.88). Females displayed knee moments and kinematics that may place them at greater risk for ACL injury during a stop-cut task. Females should be coached to perform stop cuts with more knee flexion and a more neutral knee rotation angle upon foot contact in an effort to reduce moments that may place the ACL at risk.
Dai, Yifei; Cross, Michael B; Angibaud, Laurent D; Hamad, Cyril; Jung, Amaury; Jenny, Jean-Yves
2018-02-23
Posterior tibial slope (PTS) for cruciate-retaining (CR) total knee arthroplasty (TKA) is usually pre-determined by the surgeon. Limited information is available comparing different choices of PTS on the kinematics of the CR TKA, independent of the balancing of the extension gap. This study hypothesized that with the same balanced extension gap, the choice of PTS significantly impacts the intraoperatively measured kinematics of CR TKA. Navigated CR TKAs were performed on seven fresh-frozen cadavers with healthy knees and intact posterior cruciate ligament (PCL). A custom designed tibial baseplate was implanted to allow in situ modification of the PTS, which altered the flexion gap but maintained the extension gap. Knee kinematics were measured by performing passive range of motion (ROM) tests from full extension to 120° of flexion on the intact knee and CR TKAs with four different PTSs (1°, 4°, 7°, and 10°). The measured kinematics were compared across test conditions to assess the impact of PTS. With a consistent extension gap, the change of PTS had significant impact on the anteroposterior (AP) kinematics of the CR TKA knees in mid-flexion range (45°-90°), but not so much for the high-flexion range (90°-120°). No considerable impacts were found on internal/external (I/E) rotation and hip-knee-ankle (HKA) angle. However, the findings on the individual basis suggested the impact of PTS on I/E rotation and HKA angle may be patient-specific. The data suggested that the choice of PTS had the greatest impact on the mid-flexion AP translation among the intraoperatively measured kinematics. This impact may be considered while making surgical decisions in the context of AP kinematics. When using a tibial component designed with "center" pivoting PTS, a surgeon may be able to fine tune the PTS to achieve proper mid-flexion AP stability.
Ferris, Lauren A; Denney, Linda M; Maletsky, Lorin P
2013-02-01
Functional activities in daily life can require squatting and shifting body weight during transverse plane rotations. Stability of the knee can be challenging for people with a total knee replacement (TKR) due to reduced proprioception, nonconforming articular geometry, muscle strength, and soft tissue weakness. The objective of this study was to identify strategies utilized by individuals with TKR in double-stance transferring load during rotation and flexion. Twenty-three subjects were recruited for this study: 11 TKR subjects (age: 65 ± 6 years; BMI 27.4 ± 4.1) and 12 healthy subjects (age: 63 ± 7; BMI 24.6 ± 3.8). Each subject completed a novel crossover button push task where rotation, flexion, and extension of the knee were utilized. Each subject performed two crossover reaching tasks where the subject used the opposite hand to cross over their body and press a button next to either their shoulder (high) or knee (low), then switched hands and rotated to press the opposite button, either low or high. The two tasks related to the order they pressed the buttons while crossing over, either low-to-high (L2H) or high-to-low (H2L). Force platforms measured ground reaction forces under each foot, which were then converted to lead force ratios (LFRs) based on the total force. Knee flexion angles were also measured. No statistical differences were found in the LFRs during the H2L and L2H tasks for the different groups, although differences in the variation of the loading within subjects were noted. A significant difference was found between healthy and unaffected knee angles and a strong trend between healthy and affected subject's knee angles in both H2L and L2H tasks. Large variations in the LFR at mid-task in the TKR subjects suggested possible difficulties in maintaining positional stability during these tasks. The TKR subjects maintained more of an extended knee, which is a consistent quadriceps avoidance strategy seen by other researchers in different tasks. These outcomes suggest that individuals with a TKR utilize strategies, such as keeping an extended knee, to achieve rotary tasks during knee flexion and extension. Repeated compensatory movements could result in forces that may cause difficulty over time in the hip joints or low back. Early identification of these strategies could improve TKR success and the return to activities of daily living that involve flexion and rotation.
Tateuchi, Hiroshige; Taniguchi, Masashi; Takagi, Yui; Goto, Yusuke; Otsuka, Naoki; Koyama, Yumiko; Kobayashi, Masashi; Ichihashi, Noriaki
2014-01-01
Footwear modification can beneficially alter knee loading in patients with knee osteoarthritis. This study evaluated the effect of Masai Barefoot Technology shoes on reductions in external knee moments in patients with knee osteoarthritis. Three-dimensional motion analysis was used to examine the effect of Masai Barefoot Technology versus control shoes on the knee adduction and flexion moments in 17 women (mean age, 63.6 years) with radiographically confirmed knee osteoarthritis. The lateral and anterior trunk lean values, knee flexion and adduction angles, and ground reaction force were also evaluated. The influence of the original walking pattern on the changes in knee moments with Masai Barefoot Technology shoes was evaluated. The knee flexion moment in early stance was significantly reduced while walking with the Masai Barefoot Technology shoes (0.25±0.14Nm/kgm) as compared with walking with control shoes (0.30±0.19 Nm/kgm); whereas the knee adduction moment showed no changes. Masai Barefoot Technology shoes did not increase compensatory lateral and anterior trunk lean. The degree of knee flexion moment in the original walking pattern with control shoes was correlated directly with its reduction when wearing Masai Barefoot Technology shoes by multiple linear regression analysis (adjusted R2=0.44, P<0.01). Masai Barefoot Technology shoes reduced the knee flexion moment during walking without increasing the compensatory trunk lean and may therefore reduce external knee loading in women with knee osteoarthritis. Copyright © 2014 Elsevier B.V. All rights reserved.
Gustafson, Jonathan A; Gorman, Shannon; Fitzgerald, G Kelley; Farrokhi, Shawn
2016-01-01
Increased walking knee joint stiffness has been reported in patients with knee osteoarthritis (OA) as a compensatory strategy to improve knee joint stability. However, presence of episodic self-reported knee instability in a large subgroup of patients with knee OA may be a sign of inadequate walking knee joint stiffness. The objective of this work was to evaluate the differences in walking knee joint stiffness in patients with knee OA with and without self-reported instability and examine the relationship between walking knee joint stiffness with quadriceps strength, knee joint laxity, and varus knee malalignment. Overground biomechanical data at a self-selected gait velocity was collected for 35 individuals with knee OA without self-reported instability (stable group) and 17 individuals with knee OA and episodic self-reported instability (unstable group). Knee joint stiffness was calculated during the weight-acceptance phase of gait as the change in the external knee joint moment divided by the change in the knee flexion angle. The unstable group walked with lower knee joint stiffness (p=0.01), mainly due to smaller heel-contact knee flexion angles (p<0.01) and greater knee flexion excursions (p<0.01) compared to their knee stable counterparts. No significant relationships were observed between walking knee joint stiffness and quadriceps strength, knee joint laxity or varus knee malalignment. Reduced walking knee joint stiffness appears to be associated with episodic knee instability and independent of quadriceps muscle weakness, knee joint laxity or varus malalignment. Further investigations of the temporal relationship between self-reported knee joint instability and walking knee joint stiffness are warranted. Copyright © 2015 Elsevier B.V. All rights reserved.
Gustafson, Jonathan A.; Gorman, Shannon; Fitzgerald, G. Kelley; Farrokhi, Shawn
2017-01-01
Increased walking knee joint stiffness has been reported in patients with knee osteoarthritis (OA) as a compensatory strategy to improve knee joint stability. However, presence of episodic self-reported knee instability in a large subgroup of patients with knee OA may be a sign of inadequate walking knee joint stiffness. The objective of this work was to evaluate the differences in walking knee joint stiffness in patients with knee OA with and without self-reported instability and examine the relationship between walking knee joint stiffness with quadriceps strength, knee joint laxity, and varus knee malalignment. Overground biomechanical data at a self-selected gait velocity was collected for 35 individuals with knee OA without self-reported instability (stable group) and 17 individuals with knee OA and episodic self-reported instability (unstable group). Knee joint stiffness was calculated during the weight-acceptance phase of gait as the change in the external knee joint moment divided by the change in the knee flexion angle. The unstable group walked with lower knee joint stiffness (p=0.01), mainly due to smaller heel-contact knee flexion angles (p<0.01) and greater knee flexion excursions (p<0.01) compared to their knee stable counterparts. No significant relationships were observed between walking knee joint stiffness and quadriceps strength, knee joint laxity or varus knee malalignment. Reduced walking knee joint stiffness appears to be associated with episodic knee instability and independent of quadriceps muscle weakness, knee joint laxity or varus malalignment. Further investigations of the temporal relationship between self-reported knee joint instability and walking knee joint stiffness are warranted. PMID:26481256
Marchetti, Daniel Cole; Phelps, Brian M; Dahl, Kimi D; Slette, Erik L; Mikula, Jacob D; Dornan, Grant J; Bucci, Gabriella; Turnbull, Travis Lee; Singleton, Steven B
2017-10-01
To directly compare effectiveness of the inside-out and all-inside medial meniscal repair techniques in restoring native contact area and contact pressure across the medial tibial plateau at multiple knee flexion angles. Twelve male, nonpaired (n = 12), fresh-frozen human cadaveric knees underwent a series of 5 consecutive states: (1) intact medial meniscus, (2) MCL tear and repair, (3) simulated bucket-handle longitudinal tear of the medial meniscus, (4) inside-out meniscal repair, and (5) all-inside meniscal repair. Knees were loaded with a 1,000-N axial compressive force at 5 knee flexion angles (0°, 30°, 45°, 60°, 90°), and contact area, mean contact pressure, and peak contact pressure were calculated using thin film pressure sensors. No significant differences were observed between the inside-out and all-inside repair techniques at any flexion angle for contact area, mean contact pressure, and peak contact pressure (all P > .791). Compared with the torn meniscus state, inside-out and all-inside repair techniques resulted in increased contact area at all flexion angles (all P < .005 and all P < .037, respectively), decreased mean contact pressure at all flexion angles (all P < .007 and all P < .001, respectively) except for 0° (P = .097 and P = .39, respectively), and decreased peak contact pressure at all flexion angles (all P < .001, all P < .001, respectively) except for 0° (P = .080 and P = .544, respectively). However, there were significant differences in contact area and peak contact pressure between the intact state and inside-out technique at angles ≥45° (all P < .014 and all P < .032, respectively). Additionally, there were significant differences between the intact state and all-inside technique in contact area at 60° and 90° and peak contact pressure at 90° (both P < .005 and P = .004, respectively). Median values of intact contact area, mean contact pressure, and peak contact pressure over the tested flexion angles ranged from 498 to 561 mm 2 , 786 to 997 N/mm 2 , and 1,990 to 2,215 N/mm 2 , respectively. Contact area, mean contact pressure, and peak contact pressure were not significantly different between the all-inside and inside-out repair techniques at any tested flexion angle. Both techniques adequately restored native meniscus biomechanics near an intact level. An all-inside repair technique provided similar, native-state-restoring contact mechanics compared with an inside-out repair technique for the treatment of displaced bucket-handle tears of the medial meniscus. Thus, both techniques may adequately decrease the likelihood of cartilage degeneration. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Podraza, Jeffery T; White, Scott C
2010-08-01
Investigating landing kinetics and neuromuscular control strategies during rapid deceleration movements is a prerequisite to understanding the non-contact mechanism of ACL injury. The purpose of this study was to quantify the effect of knee flexion angle on ground reaction forces, net knee joint moments, muscle co-contraction and lower extremity muscles during an impact-like, deceleration task. Ground reaction forces and knee joint moments were determined from video and force plate records of 10 healthy male subjects performing rapid deceleration single leg landings from a 10.5 cm height with different degrees of knee flexion at landing. Muscle co-contraction was based on muscle moments calculated from an EMG-to-moment processing model. Ground reaction forces and co-contraction indices decreased while knee extensor moments increased significantly with increased degrees of knee flexion at landing (all p<0.005). Higher ground reaction forces when landing in an extended knee position suggests they are a contributing factor in non-contact ACL injuries. Increased knee extensor moments and less co-contraction with flexed knee landings suggest that quadriceps overload may not be the primary cause of non-contact ACL injuries. The results bring into question the counterbalancing role of the hamstrings during dynamic movements. The soleus may be a valuable synergist stabilizing the tibia against anterior translation at landing. Movement strategies that lessen the propagation of reaction forces up the kinetic chain may help prevent non-contact ACL injuries. The relative interaction of all involved thigh and lower leg muscles, not just the quadriceps and hamstrings should be considered when interpreting non-contact ACL injury mechanisms. Copyright 2010 Elsevier B.V. All rights reserved.
Begalle, Rebecca L; Walsh, Meghan C; McGrath, Melanie L; Boling, Michelle C; Blackburn, J Troy; Padua, Darin A
2015-08-01
The ankle, knee, and hip joints work together in the sagittal plane to absorb landing forces. Reduced sagittal plane motion at the ankle may alter landing strategies at the knee and hip, potentially increasing injury risk; however, no studies have examined the kinematic relationships between the joints during jump landings. Healthy adults (N = 30; 15 male, 15 female) performed jump landings onto a force plate while three-dimensional kinematic data were collected. Joint displacement values were calculated during the loading phase as the difference between peak and initial contact angles. No relationship existed between ankle dorsiflexion displacement during landing and three-dimensional knee and hip displacements. However, less ankle dorsiflexion displacement was associated with landing at initial ground contact with larger hip flexion, hip internal rotation, knee flexion, knee varus, and smaller plantar flexion angles. Findings of the current study suggest that restrictions in ankle motion during landing may contribute to contacting the ground in a more flexed position but continuing through little additional motion to absorb the landing. Transverse plane hip and frontal plane knee positioning may also occur, which are known to increase the risk of lower extremity injury.
Seitz, Andreas Martin; Lubomierski, Anja; Friemert, Benedikt; Ignatius, Anita; Dürselen, Lutz
2012-06-01
We examined the influence of partial meniscectomy of 10 mm width on 10 human cadaveric knee joints, as it is performed during the treatment of radial tears in the posterior horn of the medial meniscus, on maximum contact pressure, contact area (CA), and meniscal hoop strain in the lateral and medial knee compartments. In case of 0° and 30° flexion angle, 20% and 50% partial meniscectomy did not influence maximum contact pressure and area. Only in case of 60° knee flexion, 50% partial resection increased medial maximum contact pressure and decreased the medial CA statistically significant. However, 100% partial resection increased maximum contact pressure and decreased CA significantly in the meniscectomized medial knee compartment in all tested knee positions. No significant differences were noted for meniscal hoop strain. From a biomechanical point of view, our in vitro study suggests that the medial joint compartment is not in danger of accelerated cartilage degeneration up to a resection limit of 20% meniscal depth and 10 mm width. Contact mechanics are likely to be more sensitive to partial meniscectomy at higher flexion angles, which has to be further investigated. Copyright © 2011 Orthopaedic Research Society.
Slater, Lindsay V; Hart, Joseph M; Kelly, Adam R; Kuenze, Christopher M
2017-09-01
Anterior cruciate ligament (ACL) injury and ACL reconstruction (ACLR) result in persistent alterations in lower extremity movement patterns. The progression of lower extremity biomechanics from the time of injury has not been described. To compare the 3-dimensional (3D) lower extremity kinematics and kinetics of walking among individuals with ACL deficiency (ACLD), individuals with ACLR, and healthy control participants from 3 to 64 months after ACLR. We searched PubMed and Web of Science from 1970 through 2013. We selected only articles that provided peak kinematic and kinetic values during walking in individuals with ACLD or ACLR and comparison with a healthy control group or the contralateral uninjured limb. A total of 27 of 511 identified studies were included. Weighted means, pooled standard deviations, and 95% confidence intervals were calculated for the healthy control, ACLD, and ACLR groups at each reported time since surgery. The magnitude of between-groups (ACLR versus ACLD, control, or contralateral limb) differences at each time point was evaluated using Cohen d effect sizes and associated 95% confidence intervals. Peak knee-flexion angle (Cohen d = -0.41) and external knee-extensor moment (Cohen d = -0.68) were smaller in the ACLD than in the healthy control group. Peak knee-flexion angle (Cohen d range = -0.78 to -1.23) and external knee-extensor moment (Cohen d range = -1.39 to -2.16) were smaller in the ACLR group from 10 to 40 months after ACLR. Reductions in external knee-adduction moment (Cohen d range = -0.50 to -1.23) were present from 9 to 42 months after ACLR. Reductions in peak knee-flexion angle, external knee-flexion moment, and external knee-adduction moment were present in the ACLD and ACLR groups. This movement profile during the loading phase of gait has been linked to knee-cartilage degeneration and may contribute to the development of osteoarthritis after ACLR.
Potvin, Brigitte M; Shourijeh, Mohammad S; Smale, Kenneth B; Benoit, Daniel L
2017-09-06
Musculoskeletal modeling and simulations have vast potential in clinical and research fields, but face various challenges in representing the complexities of the human body. Soft tissue artifact from skin-mounted markers may lead to non-physiological representation of joint motions being used as inputs to models in simulations. To address this, we have developed adaptive joint constraints on five of the six degree of freedom of the knee joint based on in vivo tibiofemoral joint motions recorded during walking, hopping and cutting motions from subjects instrumented with intra-cortical pins inserted into their tibia and femur. The constraint boundaries vary as a function of knee flexion angle and were tested on four whole-body models including four to six knee degrees of freedom. A musculoskeletal model developed in OpenSim simulation software was constrained to these in vivo boundaries during level gait and inverse kinematics and dynamics were then resolved. Statistical parametric mapping indicated significant differences (p<0.05) in kinematics between bone pin constrained and unconstrained model conditions, notably in knee translations, while hip and ankle flexion/extension angles were also affected, indicating the error at the knee propagates to surrounding joints. These changes to hip, knee, and ankle kinematics led to measurable changes in hip and knee transverse plane moments, and knee frontal plane moments and forces. Since knee flexion angle can be validly represented using skin mounted markers, our tool uses this reliable measure to guide the five other degrees of freedom at the knee and provide a more valid representation of the kinematics for these degrees of freedom. Copyright © 2017 Elsevier Ltd. All rights reserved.
Harding, Graeme T; Hubley-Kozey, Cheryl L; Dunbar, Michael J; Stanish, William D; Astephen Wilson, Janie L
2012-11-01
Obesity is a highly cited risk factor for knee osteoarthritis (OA), but its role in knee OA pathogenesis and progression is not as clear. Excess weight may contribute to an increased mechanical burden and altered dynamic movement and loading patterns at the knee. The objective of this study was to examine the interacting role of moderate knee OA disease presence and obesity on knee joint mechanics during gait. Gait analysis was performed on 104 asymptomatic and 140 individuals with moderate knee OA. Each subject group was divided into three body mass categories based on body mass index (BMI): healthy weight (BMI<25), overweight (25≤BMI≤30), and obese (BMI>30). Three-dimensional knee joint angles and net external knee joint moments were calculated and waveform principal component analysis (PCA) was applied to extract major patterns of variability from each. PC scores for major patterns were compared between groups using a two-factor ANOVA. Significant BMI main effects were found in the pattern of the knee adduction moment, the knee flexion moment, and the knee rotation moment during gait. Two interaction effects between moderate OA disease presence and BMI were also found that described different changes in the knee flexion moment and the knee flexion angle with increased BMI with and without knee OA. Our results suggest that increased BMI is associated with different changes in biomechanical patterns of the knee joint during gait depending on the presence of moderate knee OA. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Mechanical factors relate to pain in knee osteoarthritis.
Maly, Monica R; Costigan, Patrick A; Olney, Sandra J
2008-07-01
Pain experienced by people with knee osteoarthritis is related to psychosocial factors and damage to articular tissues and/or the pain pathway itself. Mechanical factors have been speculated to trigger this pain experience; yet mechanics have not been identified as a source of pain in this population. The purpose of this study was to identify whether mechanics could explain variance in pain intensity in people with knee osteoarthritis. Data from 53 participants with physician-diagnosed knee osteoarthritis (mean age=68.5 years; standard deviation=8.6 years) were analyzed. Pain intensity was reported on the Western Ontario and McMaster Universities Osteoarthritis Index. Mechanical measures included weight-bearing varus-valgus alignment, body mass index and isokinetic quadriceps torque. Gait analysis captured the range of adduction-abduction angle, range of flexion-extension angle and external knee adduction moment during level walking. Pain intensity was significantly related to the dynamic range of flexion-extension during gait and body mass index. A total of 29% of the variance in pain intensity was explained by mechanical variables. The range of flexion-extension explained 18% of variance in pain intensity. Body mass index added 11% to the model. The knee adduction moment was unrelated to pain intensity. The findings support that mechanical factors are related to knee osteoarthritis pain. Because limitations in flexion-extension range of motion and body size are modifiable factors, future research could examine whether interventions targeting these mechanics would facilitate pain management.
Bates, Nathaniel A; Nesbitt, Rebecca J; Shearn, Jason T; Myer, Gregory D; Hewett, Timothy E
2016-07-01
Tibial slope angle is a nonmodifiable risk factor for anterior cruciate ligament (ACL) injury. However, the mechanical role of varying tibial slopes during athletic tasks has yet to be clinically quantified. To examine the influence of posterior tibial slope on knee joint loading during controlled, in vitro simulation of the knee joint articulations during athletic tasks. Descriptive laboratory study. A 6 degree of freedom robotic manipulator positionally maneuvered cadaveric knee joints from 12 unique specimens with varying tibial slopes (range, -7.7° to 7.7°) through drop vertical jump and sidestep cutting tasks that were derived from 3-dimensional in vivo motion recordings. Internal knee joint torques and forces were recorded throughout simulation and were linearly correlated with tibial slope. The mean (±SD) posterior tibial slope angle was 2.2° ± 4.3° in the lateral compartment and 2.3° ± 3.3° in the medial compartment. For simulated drop vertical jumps, lateral compartment tibial slope angle expressed moderate, direct correlations with peak internally generated knee adduction (r = 0.60-0.65), flexion (r = 0.64-0.66), lateral (r = 0.57-0.69), and external rotation torques (r = 0.47-0.72) as well as inverse correlations with peak abduction (r = -0.42 to -0.61) and internal rotation torques (r = -0.39 to -0.79). Only frontal plane torques were correlated during sidestep cutting simulations. For simulated drop vertical jumps, medial compartment tibial slope angle expressed moderate, direct correlations with peak internally generated knee flexion torque (r = 0.64-0.69) and lateral knee force (r = 0.55-0.74) as well as inverse correlations with peak external torque (r = -0.34 to -0.67) and medial knee force (r = -0.58 to -0.59). These moderate correlations were also present during simulated sidestep cutting. The investigation supported the theory that increased posterior tibial slope would lead to greater magnitude knee joint moments, specifically, internally generated knee adduction and flexion torques. The knee torques that positively correlated with increased tibial slope angle in this investigation are associated with heightened risk of ACL injury. Therefore, the present data indicated that a higher posterior tibial slope is correlated to increased knee loads that are associated with heightened risk of ACL injury. © 2016 The Author(s).
Andrade, R J; Freitas, S R; Vaz, J R; Bruno, P M; Pezarat-Correia, P
2015-06-01
This study aimed to determine the influence of the head, upper trunk, and foot position on the passive knee extension (PKE) torque-angle response. PKE tests were performed in 10 healthy subjects using an isokinetic dynamometer at 2°/s. Subjects lay in the supine position with their hips flexed to 90°. The knee angle, passive torque, surface electromyography (EMG) of the semitendinosus and quadriceps vastus medialis, and stretch discomfort were recorded in six body positions during PKE. The different maximal active positions of the cervical spine (neutral; flexion; extension), thoracic spine (neutral; flexion), and ankle (neutral; dorsiflexion) were passively combined for the tests. Visual analog scale scores and EMG were unaffected by body segment positioning. An effect of the ankle joint was verified on the peak torque and knee maximum angle when the ankle was in the dorsiflexion position (P < 0.05). Upper trunk positioning had an effect on the knee submaximal torque (P < 0.05), observed as an increase in the knee passive submaximal torque when the cervical and thoracic spines were flexed (P < 0.05). In conclusion, other apparently mechanical unrelated body segments influence torque-angle response since different positions of head, upper trunk, and foot induce dissimilar knee mechanical responses during passive extension. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Slack length of gastrocnemius medialis and Achilles tendon occurs at different ankle angles.
Hug, François; Lacourpaille, Lilian; Maïsetti, Olivier; Nordez, Antoine
2013-09-27
Although muscle-tendon slack length is a crucial parameter used in muscle models, this is one of the most difficult measures to estimate in vivo. The aim of this study was to determine the onset of the rise in tension (i.e., slack length) during passive stretching in both Achilles tendon and gastrocnemius medialis. Muscle and tendon shear elastic modulus was measured by elastography (supersonic shear imaging) during passive plantarflexion (0° and 90° of knee angle, 0° representing knee fully extended, in a random order) in 9 participants. The within-session repeatability of the determined slack length was good at 90° of knee flexion (SEM=3.3° and 2.2° for Achilles tendon and gastrocnemius medialis, respectively) and very good at 0° of knee flexion (SEM=1.9° and 1.9° for Achilles tendon and gastrocnemius medialis, respectively). The slack length of gastrocnemius medialis was obtained at a significantly lower plantarflexed angle than for Achilles tendon at both 0° (P<0.0001; mean difference=19.4±3.8°) and 90° of knee flexion (P<0.0001; mean difference=25.5±7.6°). In conclusion, this study showed that the joint angle at which the tendon falls slack can be experimentally determined using supersonic shear imaging. The slack length of gastrocnemius medialis and Achilles tendon occurred at different joint angles. Although reporting this result is crucial to a better understanding of muscle-tendon interactions, further experimental investigations are required to explain this result. Copyright © 2013 Elsevier Ltd. All rights reserved.
Suzuki, Hidetomo; Omori, Go; Uematsu, Daisuke; Nishino, Katsutoshi; Endo, Naoto
2015-10-01
A smaller knee flexion angle and larger knee valgus angle during weight-bearing activities have been identified as risk factors for non-contact anterior cruciate ligament (ACL) injuries. To prevent such injuries, attention has been focused on the role of hip strength in knee motion control. However, gender differences in the relationship between hip strength and knee kinematics during weight-bearing activities in the frontal plane have not been evaluated. The purpose of this study was to determine the influence of hip strength on knee kinematics in both genders during a single-legged landing task in the frontal plane. The hypotheses were that 1) subjects with a greater hip strength would demonstrate larger knee flexion and smaller knee valgus and internal rotation angles and 2) no gender differences would exist during the single-legged landing task. Forty-three Japanese collegiate basketball players (20 males, 23 females) participated in this study. Three-dimensional motion analysis was used to evaluate knee kinematics during a single-legged medial drop landing (SML). A hand-held dynamometer was used to assess hip extensor (HEXT), abductor (HAB), and external rotator (in two positions: seated position [SHER] and prone [PHER]) isometric strength. Spearman rank correlation coefficients (ρ) were determined for correlations between hip strength and knee kinematics at initial contact (IC) and peak (PK) during SML (p < 0.05). Negative correlations were observed between the knee valgus angle at IC and HEXT (ρ = -0.48, p = 0.02), HAB (ρ = -0.46, p = 0.03) and PHER (ρ = -0.44, p = 0.04) strength in females. In addition, a significant positive correlation was observed between the knee flexion angle at PK and HEXT strength (ρ = 0.61, p = 0.004) in males. Significant correlations between hip strength and knee kinematics during SML were observed in both genders. Hip strength may, therefore, play an important role in knee motion control during sports activities, suggesting that increased hip strength may help to prevent non-contact ACL injuries in athletes of both genders. Moreover, gender-specific programs may be needed to control abnormal knee motion, as the influence of hip strength on knee kinematics may differ based on gender. 3.
Core strength and lower extremity alignment during single leg squats.
Willson, John D; Ireland, Mary Lloyd; Davis, Irene
2006-05-01
Muscles of the trunk, hip, and knee influence the orientation of the lower extremity during weight bearing activities. The purpose of this study was threefold: first, to compare the orientation of the lower extremity during a single leg (SL) squat among male and female athletes; second, to compare the strength of muscle groups in the trunk, hips, and knees between these individuals; and third, to evaluate the association between trunk, hip, and knee strength and the orientation of the knee joint during this activity. Twenty-four male and 22 female athletes participated in this study. Peak isometric torque was determined for the following muscle actions: trunk flexion, extension, and lateral flexion, hip abduction and external rotation, and knee flexion and extension. The frontal plane projection angle (FPPA) of the knee during a 45 degrees SL squat was determined using photo editing software. Males and females moved in opposite directions during the SL squat test (F(1,42) = 5.05, P = 0.03). Females typically moved toward more extreme FPPA during SL squats (P = 0.056), while males tended to move toward more neutral alignment (P = 0.066). Females also generated less torque in all muscle groups, with the exception of trunk extension. The projection angle of the knee during the SL squat test was most closely associated with hip external rotation strength. Using instruments suitable for a clinical setting, females were found to have greater FPPA and generally decreased trunk, hip, and knee isometric torque. Hip external rotation strength was most closely associated with the frontal plane projection angle.
Guess, Trent M; Razu, Swithin; Jahandar, Amirhossein; Skubic, Marjorie; Huo, Zhiyu
2017-04-01
The Microsoft Kinect is becoming a widely used tool for inexpensive, portable measurement of human motion, with the potential to support clinical assessments of performance and function. In this study, the relative osteokinematic Cardan joint angles of the hip and knee were calculated using the Kinect 2.0 skeletal tracker. The pelvis segments of the default skeletal model were reoriented and 3-dimensional joint angles were compared with a marker-based system during a drop vertical jump and a hip abduction motion. Good agreement between the Kinect and marker-based system were found for knee (correlation coefficient = 0.96, cycle RMS error = 11°, peak flexion difference = 3°) and hip (correlation coefficient = 0.97, cycle RMS = 12°, peak flexion difference = 12°) flexion during the landing phase of the drop vertical jump and for hip abduction/adduction (correlation coefficient = 0.99, cycle RMS error = 7°, peak flexion difference = 8°) during isolated hip motion. Nonsagittal hip and knee angles did not correlate well for the drop vertical jump. When limited to activities in the optimal capture volume and with simple modifications to the skeletal model, the Kinect 2.0 skeletal tracker can provide limited 3-dimensional kinematic information of the lower limbs that may be useful for functional movement assessment.
Ishida, Kazunari; Shibanuma, Nao; Matsumoto, Tomoyuki; Sasaki, Hiroshi; Takayama, Koji; Hiroshima, Yuji; Kuroda, Ryosuke; Kurosaka, Masahiro
2016-08-01
In clinical practice, people with better femorotibial rotation in the flexed position often achieve a favourable postoperative maximum flexion angle (MFA). However, no objective data have been reported to support this clinical observation. In the present study, we aimed to investigate the correlation between the amount of intraoperative rotation and the pre- and postoperative flexion angles. Fifty-five patients with varus osteoarthritis undergoing computer-assisted posterior-stabilized total knee arthroplasty (TKA) were enrolled. After registration, rotational stress was applied towards the knee joint, and the rotational angles were recorded by using a navigation system at maximum extension and 90° of flexion. After implantation, rotational stress was applied for a second time, and the angles were recorded once more. The MFA was measured before surgery and 1 month after surgery, and the correlation between the amount of femorotibial rotation during surgery and the MFA was statistically evaluated. Although the amount of tibial rotation at maximum extension was not correlated with the MFA, the amount of tibial rotation at 90° of flexion after registration was positively correlated with the pre- and postoperative MFA (both p < 0.005). However, no significant relationship was observed between the amount of tibial rotation after implantation and the postoperative MFA (n.s.). The results showed that better femorotibial rotation at 90° of flexion is associated with a favourable postoperative MFA, suggesting that the flexibility of the surrounding soft tissues is an important factor for obtaining a better MFA, which has important clinical relevance. Hence, further evaluation of navigation-based kinematics during TKA may provide useful information on MFA. Diagnostic studies, development of diagnostic criteria in a consecutive series of patients, and a universally applied "gold" standard, Level II.
Lopes, Thiago Jambo Alves; Simic, Milena; Myer, Gregory D; Ford, Kevin R; Hewett, Timothy E; Pappas, Evangelos
2018-05-01
Anterior cruciate ligament (ACL) tear is a common injury in sports and often occurs during landing from a jump. To synthesize the evidence on the effects of injury prevention programs (IPPs) on landing biomechanics as they relate to the ligament, quadriceps, trunk, and leg dominance theories associated with ACL injury risk. Meta-analysis. Six electronic databases were searched for studies that investigated the effect of IPPs on landing task biomechanics. Prospective studies that reported landing biomechanics at baseline and post-IPP were included. Results from trunk, hip, and knee kinematics and kinetics related to the ACL injury theories were extracted, and meta-analyses were performed when possible. The criteria were met by 28 studies with a total of 466 participants. Most studies evaluated young females, bilateral landing tasks, and recreational athletes, while most variables were related to the ligament and quadriceps dominance theories. An important predictor of ACL injury, peak knee abduction moment, decreased ( P = .01) after the IPPs while other variables related to the ligament dominance theory did not change. Regarding the quadriceps dominance theory, after the IPPs, angles of hip flexion at initial contact ( P = .009), peak hip flexion ( P = .002), and peak knee flexion ( P = .007) increased, while knee flexion at initial contact did not change ( P = .18). Moreover, peak knee flexion moment decreased ( P = .005) and peak vertical ground-reaction force did not change ( P = .10). The exercises used in IPPs might have the potential to improve landing task biomechanics related to the quadriceps dominance theory, especially increasing peak knee and hip flexion angles. Importantly, peak knee abduction moment decreased, which indicates that IPPs influence a desired movement strategy to help athletes overcome dangerous ligament dominance loads arising from lack of frontal plane control during dynamic tasks. The lack of findings for some biomechanical variables suggests that future IPPs may be enhanced by targeting participants' baseline profile deficits, highlighting the need to deliver an individualized and task-specific IPP.
Eitzen, I; Eitzen, TJ; Holm, I; Snyder-Mackler, L; Risberg, MA
2011-01-01
Background Isokinetic muscle strength tests using the peak torque value is the most frequently included quadriceps muscle strength measurement for anterior cruciate ligament (ACL) injured subjects. Aims The purpose of this study was to investigate quadriceps muscle performance during the whole isokinetic curve in ACL deficient subjects classified as potential copers or non-copers, and investigate whether these curve profiles were associated with single-leg hop performance. We hypothesized that quadriceps muscle torque at other knee flexion angles than peak torque would give more information about quadriceps muscle strength deficits. Furthermore, we hypothesized that there would be significant torque differences between potential copers and non-copers, and a significant relationship between angle specific torque values and single-leg hop performance. Study Design Cross-sectional study; Level of evidence, 2 Methods Seventy-six individuals with a complete unilateral ACL rupture within the last 3 months were included. The subjects were classified into potential copers and non-copers according to the criteria from Fitzgerald et al12. Isokinetic quadriceps muscle tests were performed at 60°/sec (Biodex 6000). Mean torque values were calculated for peak torque as well as for specific knee flexion angles. The one-leg hop and the 6 meter timed hop tests were included and symmetry indices were used. Results The peak torque value did not identify the largest quadriceps muscle strength deficit. Rather, these were established at knee flexion angles of less than 40°. There were significant differences in angle specific torque values between potential copers and non-copers (p<0.05). Moderate to strong associations were disclosed between angle specific torque values and single-leg hop performance, but only for non-copers (r≥0.32– 0.58). Conclusions Angle specific quadriceps muscle torque values of less than 40° of knee flexion provide more information on the quadriceps strength deficits after ACL injury compared to the commonly used peak torque values. PMID:20110458
Chon, Jegyun; Shin, Sangyeop; Jang, Gunil; Jeon, Taehyeon
2016-01-01
Background We investigated the causes of impingement between the patella bone and the bearing post during high flexion in cruciate-substituting total knee arthroplasty and proposed a treatment strategy. Methods This prospective cohort study included 218 cases that had undergone cruciate-substituting total knee arthroplasty from February 2014 to January 2015; a single surgeon performed the operation using the same method without patellar resurfacing in all patients. Results In these patients, the occurrence of impingement was determined by performing more than 120° high knee flexion after inserting a bearing perioperatively. The incidence of impingement was significantly associated with bearing design, femoral implant size, patella bone length, and patella inferior pole angle (p < 0.05). The impingement was resolved by resection of the lower articular side of the patella bone. Conclusions In the cruciate-substituting high-flexion total knee arthroplasty, impingement between the patella bone and bearing post was more common in patients with mobile bearing, small-size femoral component, and a long patella or a large inferior pole angle. In cases of intraoperative impingement between the patella bone and the bearing post, resection in the lower portion of the patella prevented impingement of the bearing with soft tissue or the patella by widening the space between the patella and the bearing post, which in turn prevented postoperative reduction in range of motion. PMID:27247740
Chon, Jegyun; Lee, Bongju; Shin, Sangyeop; Jang, Gunil; Jeon, Taehyeon
2016-06-01
We investigated the causes of impingement between the patella bone and the bearing post during high flexion in cruciate-substituting total knee arthroplasty and proposed a treatment strategy. This prospective cohort study included 218 cases that had undergone cruciate-substituting total knee arthroplasty from February 2014 to January 2015; a single surgeon performed the operation using the same method without patellar resurfacing in all patients. In these patients, the occurrence of impingement was determined by performing more than 120° high knee flexion after inserting a bearing perioperatively. The incidence of impingement was significantly associated with bearing design, femoral implant size, patella bone length, and patella inferior pole angle (p < 0.05). The impingement was resolved by resection of the lower articular side of the patella bone. In the cruciate-substituting high-flexion total knee arthroplasty, impingement between the patella bone and bearing post was more common in patients with mobile bearing, small-size femoral component, and a long patella or a large inferior pole angle. In cases of intraoperative impingement between the patella bone and the bearing post, resection in the lower portion of the patella prevented impingement of the bearing with soft tissue or the patella by widening the space between the patella and the bearing post, which in turn prevented postoperative reduction in range of motion.
A dynamic study of the anterior cruciate ligament of the knee using an open MRI.
Guenoun, Daphne; Vaccaro, Julien; Le Corroller, Thomas; Barral, Pierre-Antoine; Lagier, Aude; Pauly, Vanessa; Coquart, Benjamin; Coste, Joel; Champsaur, Pierre
2017-03-01
Recent anatomical and radiological studies of the anterior cruciate ligament (ACL) suggest the ACL length and orientation change during knee flexion, and an open MRI sequencing during knee flexion enables a dynamic ACL analysis. This study's goal is to describe a normal ACL using a 1T open MRI and, in particular, variations in length and insertion angles at different degrees of flexion. Twenty-one volunteers with clinically healthy knees received a dynamic MRI with their knees in hyperextension, neutral position, and flexed at 45° and 90° angles. For each position, two radiologists measured the ACL lengths and angles of the proximal insertion between the ACL's anterior edge and the roof of the inter-condylar notch. Additionally, we measured the ACL's and the tibial plateau's distal angle insertion between their anterior edges and then compared these with the nonparametric Wilcoxon test. The ACL had a significant extension between the 90° flexion and all other positions (hyperextension: 31.75 ± 2.5 mm, neutral position: 32.5 ± 2.6 mm, 45°: 35.6 ± 1.6 mm, 90°: 35.6 ± 1.6 mm). There was also a significant increase of the angle insertion between the proximal 90° flexion and all other positions, as well as between hyperextension and bending to 45° (hyperextension: 2.45° ± 3.7°, neutral: 13.4° ± 9.7°, 45°: 33 25 ± 9.3, 90: 51.85° ± 9.3°). Additionally, there is a significant increase in the distal angle insertion for all positions (hyperextension: 133.2° ± 5.4°, neutral position: 134.95° ± 4.4°, 45°: 138.35° ± 5.9°, 90°: 149.15° ± 8.6°). Our study is the first to exhibit that a dynamic MRI has a significant ACL extension in vivo during bending. This concept opens the way for further studies to improve the diagnosis of traumatic ACL injuries using a dynamic MRI.
Cheng, Xiaofei; Zhang, Feng; Wu, Jigong; Zhu, Zhenan; Dai, Kerong; Zhao, Jie
2016-08-15
A retrospective study. The aim of this study was to investigate the correlation between pelvic incidence (PI) and lumbar lordosis (LL) mismatch and knee flexion during standing in patients with lumbar degenerative diseases and to examine the effects of surgical correction of the PI-LL mismatch on knee flexion. Only several studies focused on knee flexion as a compensatory mechanism of the PI-LL mismatch. Little information is currently available on the effects of lumbar correction on knee flexion in patients with the PI-LL mismatch. A group of patients with lumbar degenerative diseases were divided into PI-LL match group (PI-LL ≤ 10°) and PI-LL mismatch group (PI-LL > 10°). A series of radiographic parameters and knee flexion angle (KFA) were compared between the two groups. The PI-LL mismatch group was further subdivided into operative and nonoperative group. The changes in KFA with PI-LL were examined. The PI-LL mismatch group exhibited significantly greater sagittal vertical axis (SVA), pelvic tilt (PT) and KFA, and smaller LL, thoracic kyphosis (TK), and sacral slope than the PI-LL match group. PI-LL, LL, PI, SVA, and PT were significantly correlated with KFA in the PI-LL mismatch group. From baseline to 6-month follow-up, all variables were significantly different in the operative group with the exception of PI, although there was no significant difference in any variable in the nonoperative group. The magnitude of surgical correction in the PI-LL mismatch was significantly correlated with the degree of spontaneous changes in KFA, PT, and TK. The PI-LL mismatch would contribute to compensatory knee flexion during standing in patients with lumbar degenerative disease. Surgical correction of the PI-LL mismatch could lead to a spontaneous improvement of compensatory knee flexion. The degree of improvement in knee flexion depends in part on the amount of correction in the PI-LL mismatch. 3.
Seo, Jeong-Hee; Li, Guoan; Shetty, Gautam M; Kim, Ji-Hoon; Bae, Ji-Hoon; Jo, Myoung-Lae; Kim, Jung-Sung; Lee, Sung-Jae; Nha, Kyung-Wook
2009-11-01
Our purpose was to evaluate the result of radial tears at the root of the posterior horn of the medial meniscus (PHMM) in terms of tibiofemoral contact mechanics and the effectiveness of pullout sutures for such tears. Eleven mature pig knees each underwent 15 different testing conditions with an intact, simulated (incised) radial tear at the root of the PHMM and placement of pullout sutures in the radial tears of the medial meniscus at 5 different angles of flexion (0 degrees, 15 degrees, 30 degrees, 60 degrees, and 90 degrees ) under a 1,500-N axial load. A K-Scan pressure sensor (Tekscan, Boston, MA) was used to measure medial tibiofemoral contact area and peak tibiofemoral contact pressure. Data were analyzed to assess the difference in medial contact area and tibiofemoral peak contact pressure among the 3 meniscal conditions at various degrees of knee flexion. The mean contact area was significantly lower, and the peak tibiofemoral contact pressure was significantly high in knees with simulated radial tears at all angles of knee flexion compared with knees with intact menisci (P < .0001). The peak tibiofemoral contact pressure after the pullout suture technique was significantly high at 0 degrees and 15 degrees of flexion (P < .0001) compared with intact knee specimens. Failure of sutures occurred in 45% of the specimens at 0 degrees of flexion. Radial tears at the root of the PHMM in a porcine model significantly increased medial tibiofemoral contact pressure and decreased contact area. Although repair of tears of the PHMM with the pullout suture technique aids in significantly reducing tibiofemoral peak contact pressure between 30 degrees and 90 degrees , it remains significantly high at 0 degrees and 15 degrees of flexion. Pullout sutures for radial tears at the root of the PHMM may lead to an increase in peak medial tibiofemoral contact pressure and may be prone to mechanical failure, especially during the stance (loading) phase of gait (mean, 15 degrees of flexion).
Design, analysis and verification of a knee joint oncological prosthesis finite element model.
Zach, Lukáš; Kunčická, Lenka; Růžička, Pavel; Kocich, Radim
2014-11-01
The aim of this paper was to design a finite element model for a hinged PROSPON oncological knee endoprosthesis and to verify the model by comparison with ankle flexion angle using knee-bending experimental data obtained previously. Visible Human Project CT scans were used to create a general lower extremity bones model and to compose a 3D CAD knee joint model to which muscles and ligaments were added. Into the assembly the designed finite element PROSPON prosthesis model was integrated and an analysis focused on the PEEK-OPTIMA hinge pin bushing stress state was carried out. To confirm the stress state analysis results, contact pressure was investigated. The analysis was performed in the knee-bending position within 15.4-69.4° hip joint flexion range. The results showed that the maximum stress achieved during the analysis (46.6 MPa) did not exceed the yield strength of the material (90 MPa); the condition of plastic stability was therefore met. The stress state analysis results were confirmed by the distribution of contact pressure during knee-bending. The applicability of our designed finite element model for the real implant behaviour prediction was proven on the basis of good correlation of the analytical and experimental ankle flexion angle data. Copyright © 2014 Elsevier Ltd. All rights reserved.
Lower-limb kinematics of single-leg squat performance in young adults.
Horan, Sean A; Watson, Steven L; Carty, Christopher P; Sartori, Massimo; Weeks, Benjamin K
2014-01-01
To determine the kinematic parameters that characterize good and poor single-leg squat (SLS) performance. A total of 22 healthy young adults free from musculoskeletal impairment were recruited for testing. For each SLS, both two-dimensional video and three-dimensional motion analysis data were collected. Pelvis, hip, and knee angles were calculated using a reliable and validated lower-limb (LL) biomechanical model. Two-dimensional video clips of SLSs were blindly assessed in random order by eight musculoskeletal physiotherapists using a 10-point ordinal scale. To facilitate between-group comparisons, SLS performances were stratified by tertiles corresponding to poor, intermediate, and good SLS performance. Mean ratings of SLS performance assessed by physiotherapists were 8.3 (SD 0.5), 6.8 (SD 0.7), and 4.0 (SD 0.8) for good, intermediate, and poor squats, respectively. Three-dimensional analysis revealed that people whose SLS performance was assessed as poor exhibited increased hip adduction, reduced knee flexion, and increased medio-lateral displacement of the knee joint centre compared to those whose SLS performance was assessed as good (p≤0.05). Overall, poor SLS performance is characterized by inadequate knee flexion and excessive frontal plane motion of the knee and hip. Future investigations of SLS performance should consider standardizing knee flexion angle to illuminate other influential kinematic parameters.
Xu, Yan; Liu, Jianyu; Kramer, Scott; Martins, Cesar; Kato, Yuki; Linde-Rosen, Monica; Smolinski, Patrick; Fu, Freddie H
2011-02-01
High tunnel placement is common in single- and double-bundle anterior cruciate ligament (ACL) reconstructions. Similar nonanatomic tunnel placement may also occur in ACL augmentation surgery. In this study, in situ forces and knee kinematics were compared between nonanatomic high anteromedial (AM) and anatomic AM augmentation in a knee with isolated AM bundle injury. Controlled laboratory study. Seven fresh-frozen cadaver knees were used (age, 48 ± 12.5 years). First, intact knee kinematics was tested with a robotic-universal force sensor testing system under 2 loading conditions. An 89-N anterior load was applied, and an anterior tibial translation was measured at knee flexion angles of 0°, 30°, 60°, and 90°. Then, combined rotatory loads of 7-N·m valgus and 5-N·m internal tibial rotation were applied at 15° and 30° of knee flexion angles, which mimic the pivot shift. Afterward, only the AM bundle of the ACL was cut arthroscopically, keeping the posterolateral bundle intact. The knee was again tested using the intact knee kinematics to measure the in situ force of the AM bundle. Then, arthroscopic anatomic AM bundle reconstruction was performed with an allograft, and the knee was tested to give the in situ force of the reconstructed AM bundle. Knee kinematics under the 3 conditions (intact, anatomic AM augmentation, and nonanatomic high AM augmentation) and the in situ force were compared and analyzed. The high AM graft had significantly lower in situ force than the intact and anatomic reconstructed AM bundle at 0° of knee flexion (P < .05) and the intact AM bundle at 30° of knee flexion under anterior tibial loading. There were no differences between anatomic graft and intact AM bundle. The high AM graft also had a significantly lower in situ force than the intact and anatomic reconstructed AM with simulated pivot-shift loading at 15° and 30° of flexion (P < .05). Under anterior tibial and rotatory loading, there was a difference in tibial displacement between anatomic and high AM reconstructions and between the high AM graft and intact ACL under rotational loading with the knee at 15° of flexion. Anatomic AM augmentation can lead to biomechanical advantages at time zero when compared with the nonanatomic (high AM) augmentation. Anatomic AM augmentation better restores the knee kinematics to the intact ACL state.
Stance controlled knee flexion improves stimulation driven walking after spinal cord injury
2013-01-01
Background Functional neuromuscular stimulation (FNS) restores walking function after paralysis from spinal cord injury via electrical activation of muscles in a coordinated fashion. Combining FNS with a controllable orthosis to create a hybrid neuroprosthesis (HNP) has the potential to extend walking distance and time by mechanically locking the knee joint during stance to allow knee extensor muscle to rest with stimulation turned off. Recent efforts have focused on creating advanced HNPs which couple joint motion (e.g., hip and knee or knee and ankle) to improve joint coordination during swing phase while maintaining a stiff-leg during stance phase. Methods The goal of this study was to investigate the effects of incorporating stance controlled knee flexion during loading response and pre-swing phases on restored gait. Knee control in the HNP was achieved by a specially designed variable impedance knee mechanism (VIKM). One subject with a T7 level spinal cord injury was enrolled and served as his own control in examining two techniques to restore level over-ground walking: FNS-only (which retained a stiff knee during stance) and VIKM-HNP (which allowed controlled knee motion during stance). The stimulation pattern driving the walking motion remained the same for both techniques; the only difference was that knee extensor stimulation was constant during stance with FNS-only and modulated together with the VIKM to control knee motion during stance with VIKM-HNP. Results Stance phase knee angle was more natural during VIKM-HNP gait while knee hyperextension persisted during stiff-legged FNS-only walking. During loading response phase, vertical ground reaction force was less impulsive and instantaneous gait speed was increased with VIKM-HNP, suggesting that knee flexion assisted in weight transfer to the leading limb. Enhanced knee flexion during pre-swing phase also aided flexion during swing, especially when response to stimulation was compromised. Conclusions These results show the potential advantages of incorporating stance controlled knee flexion into a hybrid neuroprosthesis for walking. The addition of such control to FNS driven walking could also enable non-level walking tasks such as uneven terrain, slope navigation and stair descent where controlled knee flexion during weight bearing is critical. PMID:23826711
Thomas, Abbey C; Lepley, Lindsey K; Wojtys, Edward M; McLean, Scott G; Palmieri-Smith, Riann M
2015-12-01
Laboratory-based experiment using a pretest/posttest design. To determine the effects of neuromuscular fatigue on quadriceps strength and activation and sagittal and frontal plane knee biomechanics during dynamic landing following anterior cruciate ligament reconstruction (ACLR). Impaired quadriceps central activation occurs post-ACLR, likely altering lower extremity biomechanics. Neuromuscular fatigue similarly reduces volitional muscle activation and impairs neuromuscular control. Upon return to full activity post-ACLR, individuals likely concurrently experience quadriceps central activation deficits and neuromuscular fatigue, though the effects of fatigue on muscle strength and activation and biomechanics post-ACLR are unknown. Seventeen individuals 7 to 10 months post-ACLR and 16 controls participated. Quadriceps strength and central activation ratio were recorded prefatigue and postfatigue, which was induced via sets of double-leg squats. Knee biomechanics were recorded during a dynamic landing activity prefatigue and postfatigue. Both groups demonstrated smaller knee flexion (initial contact, P = .017; peak, P = .004) and abduction (initial contact, P = .005; peak, P = .009) angles postfatigue. The ACLR group had smaller peak knee flexion angles (P<.001) prefatigue and postfatigue than controls. Knee flexion moment was smaller in those post-ACLR than controls prefatigue (P<.001), but not postfatigue (P = .103). Controls had smaller knee flexion moments postfatigue (P = .001). Knee abduction moment was smaller in both groups postfatigue (P = .003). All participants demonstrated significantly lower strength (P<.001) and activation (P = .003) postfatigue. Impaired strength, central activation, and biomechanics were present postfatigue in both groups, suggesting that neuromuscular fatigue may increase noncontact ACL injury risk. However, these changes were not exaggerated in those post-ACLR, likely because they already demonstrated a stiff-legged landing strategy prefatigue.
Chang, A H; Chmiel, J S; Almagor, O; Guermazi, A; Prasad, P V; Moisio, K C; Belisle, L; Zhang, Y; Hayes, K; Sharma, L
2017-02-01
Knee sagittal dynamic joint stiffness (DJS) describes the biomechanical interaction between change in external knee flexion moment and flexion angular excursion during gait. In theory, greater DJS may particularly stress the patellofemoral (PF) compartment and thereby contribute to PF osteoarthritis (OA) worsening. We hypothesized that greater baseline knee sagittal DJS is associated with PF cartilage damage worsening 2 years later. Participants all had OA in at least one knee. Knee kinematics and kinetics during gait were recorded using motion capture systems and force plates. Knee sagittal DJS was computed as the slope of the linear regression line for knee flexion moments vs angles during the loading response phase. Knee magnetic resonance imaging (MRI) scans were obtained at baseline and 2 years later. We assessed the association between baseline DJS and baseline-to-2-year PF cartilage damage worsening using logistic regression with generalized estimating equations (GEE). Our sample had 391 knees (204 persons): mean age 64.2 years (SD 10.0); body mass index (BMI) 28.4 kg/m 2 (5.7); 76.5% women. Baseline knee sagittal DJS was associated with baseline-to-2-year cartilage damage worsening in the lateral (OR = 5.35, 95% CI: 2.37-12.05) and any PF (OR = 2.99, 95% CI: 1.27-7.04) compartment. Individual components of baseline DJS (i.e., change in knee moment or angle) were not associated with subsequent PF disease worsening. Capturing the concomitant effect of knee kinetics and kinematics during gait, knee sagittal DJS is a potentially modifiable risk factor for PF disease worsening. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Chang, Alison H.; Chmiel, Joan S.; Almagor, Orit; Guermazi, Ali; Prasad, Pottumarthi V.; Moisio, Kirsten C.; Belisle, Laura; Zhang, Yunhui; Hayes, Karen; Sharma, Leena
2016-01-01
Objective Knee sagittal dynamic joint stiffness (DJS) describes the biomechanical interaction between change in external knee flexion moment and flexion angular excursion during gait. In theory, greater DJS may particularly stress the patellofemoral (PF) compartment and thereby contribute to PF osteoarthritis (OA) worsening. We hypothesized that greater baseline knee sagittal DJS is associated with PF cartilage damage worsening 2 years later. Methods Participants all had OA in at least one knee. Knee kinematics and kinetics during gait were recorded using motion capture systems and force plates. Knee sagittal DJS was computed as the slope of the linear regression line for knee flexion moments vs. angles during the loading response phase. Knee MRI scans were obtained at baseline and 2 years later. We assessed the association between baseline DJS and baseline-to-2-year PF cartilage damage worsening using logistic regression with generalized estimating equations. Results Our sample had 391 knees (204 persons): mean age 64.2 years (SD 10.0); BMI 28.4 kg/m2 (5.7); 76.5% women. Baseline knee sagittal DJS was associated with baseline-to-2-year cartilage damage worsening in the lateral (OR=5.35, 95% CI: 2.37–12.05) and any PF (OR=2.99, 95% CI: 1.27–7.04) compartment. Individual components of baseline DJS (i.e., change in knee moment or angle) were not associated with subsequent PF disease worsening. Conclusion Capturing the concomitant effect of knee kinetics and kinematics during gait, knee sagittal DJS is a potentially modifiable risk factor for PF disease worsening. PMID:27729289
Kinematic Patterns Associated with the Vertical Force Produced during the Eggbeater Kick.
Oliveira, Nuno; Chiu, Chuang-Yuan; Sanders, Ross H
2015-01-01
The purpose of this study was to determine the kinematic patterns that maximized the vertical force produced during the water polo eggbeater kick. Twelve water polo players were tested executing the eggbeater kick with the trunk aligned vertically and with the upper limbs above water while trying to maintain as high a position as possible out of the water for nine eggbeater kick cycles. Lower limb joint angular kinematics, pitch angles and speed of the feet were calculated. The vertical force produced during the eggbeater kick cycle was calculated using inverse dynamics for the independent lower body segments and combined upper body segments, and a participant-specific second-degree regression equation for the weight and buoyancy contributions. Vertical force normalized to body weight was associated with hip flexion (average, r = 0.691; maximum, r = 0.791; range of motion, r = 0.710), hip abduction (maximum, r = 0.654), knee flexion (average, r = 0.716; minimum, r = 0.653) and knee flexion-extension angular velocity (r = 0.758). Effective orientation of the hips resulted in fast horizontal motion of the feet with positive pitch angles. Vertical motion of the feet was negatively associated with vertical force. A multiple regression model comprising the non-collinear variables of maximum hip abduction, hip flexion range of motion and knee flexion angular velocity accounted for 81% of the variance in normalized vertical force. For high performance in the water polo, eggbeater kick players should execute fast horizontal motion with the feet by having large abduction and flexion of the hips, and fast extension and flexion of the knees.
Matsumoto, Tomoyuki; Shibanuma, Nao; Takayama, Koji; Sasaki, Hiroshi; Ishida, Kazunari; Matsushita, Takehiko; Kuroda, Ryosuke; Kurosaka, Masahiro
2016-06-01
Appropriate soft tissue balance is essential for the success of total knee arthroplasty (TKA), and assessment with an offset-type tensor provides useful information about the femorotibial (FT) joint. The purpose of the study was to investigate the relationship between intraoperative soft tissue balance and patellar pressure at both medial and lateral sides. Thirty varus-type osteoarthritis patients who received mobile-bearing posterior-stabilized TKAs were enrolled in the study. Using the tensor, soft tissue balance, including joint component gap and varus ligament balance, was recorded at 0°, 10°, 30°, 60°, 90°, 120°, and 135° with patellofemoral (PF) joint reduction and femoral component placement. Following final prostheses implanted with appropriate insert, the medial and lateral patellar pressures were measured at each flexion angle. A simple regression analysis was performed between each patellar pressure, parameter of soft tissue balance, and postoperative flexion angle. Both lateral and medial patellar pressures increased with flexion. The lateral patellar pressure was significantly higher than the medial patellar pressure at 60°, 90°, and 135° of flexion (p<0.05). The lateral patellar pressure inversely correlated with the varus ligament balance at 60° and 90° of flexion (p<0.05). The lateral patellar pressure at 120° and 135° of flexion inversely correlated with the postoperative flexion angle (p<0.05). Soft tissue balance influenced patellar pressure. In particular, a reduced lateral patellar pressure was found at the lateral laxity at flexion, leading to high postoperative flexion angle. III. Copyright © 2016 Elsevier B.V. All rights reserved.
Do changes in neuromuscular activation contribute to the knee extensor angle-torque relationship?
Lanza, Marcel B; Balshaw, Thomas G; Folland, Jonathan P
2017-08-01
What is the central question of the study? Do changes in neuromuscular activation contribute to the knee extensor angle-torque relationship? What is the main finding and its importance? Both agonist (quadriceps) and antagonist coactivation (hamstrings) differed with knee joint angle during maximal isometric knee extensions and thus both are likely to contribute to the angle-torque relationship. Specifically, two independent measurement techniques showed quadriceps activation to be lower at more extended positions. These effects might influence the capacity for neural changes in response to training and rehabilitation at different knee joint angles. The influence of joint angle on knee extensor neuromuscular activation is unclear, owing in part to the diversity of surface electromyography (sEMG) and/or interpolated twitch technique (ITT) methods used. The aim of the study was to compare neuromuscular activation, using rigorous contemporary sEMG and ITT procedures, during isometric maximal voluntary contractions (iMVCs) of the quadriceps femoris at different knee joint angles and examine whether activation contributes to the angle-torque relationship. Sixteen healthy active men completed two familiarization sessions and two experimental sessions of isometric knee extension and knee flexion contractions. The experimental sessions included the following at each of four joint angles (25, 50, 80 and 106 deg): iMVCs (with and without superimposed evoked doublets); submaximal contractions with superimposed doublets; and evoked twitch and doublet contractions whilst voluntarily passive, and knee flexion iMVC at the same knee joint positions. The absolute quadriceps femoris EMG was normalized to the peak-to-peak amplitude of an evoked maximal M-wave, and the doublet-voluntary torque relationship was used to calculate activation with the ITT. Agonist activation, assessed with both normalized EMG and the ITT, was reduced at the more extended compared with the more flexed positions (25 and 50 versus 80 and 106 deg; P ≤ 0.016), whereas antagonist coactivation was greatest in the most flexed compared with the extended positions (106 versus 25 and 50 deg; P ≤ 0.02). In conclusion, both agonist and antagonist activation differed with knee joint angle during knee extension iMVCs, and thus both are likely to contribute to the knee extensor angle-torque relationship. © 2017 The Authors. Experimental Physiology © 2017 The Physiological Society.
Assessment of the midflexion rotational laxity in posterior-stabilized total knee arthroplasty.
Hino, Kazunori; Kutsuna, Tatsuhiko; Oonishi, Yoshio; Watamori, Kunihiko; Kiyomatsu, Hiroshi; Iseki, Yasutake; Watanabe, Seiji; Ishimaru, Yasumitsu; Miura, Hiromasa
2017-11-01
To evaluate changes in midflexion rotational laxity before and after posterior-stabilized (PS)-total knee arthroplasty (TKA). Twenty-nine knees that underwent PS-TKA were evaluated. Manual mild passive rotational stress was applied to the knees, and the internal-external rotational angle was measured automatically by a navigation system at 30°, 45°, 60°, and 90° of knee flexion. The post-operative internal rotational laxity was statistically significantly increased compared to the preoperative level at 30°, 45°, 60°, and 90° of flexion. The post-operative external rotational laxity was statistically significantly decreased compared to the preoperative level at 45° and 60° of flexion. The post-operative internal-external rotational laxity was statistically significantly increased compared to the preoperative level only at 30° of flexion. The preoperative and post-operative rotational laxity showed a significant correlation at 30°, 45°, 60°, and 90° of flexion. Internal-external rotational laxity increases at the initial flexion range due to resection of both the anterior or posterior cruciate ligaments and retention of the collateral ligaments in PS-TKA. Preoperative and post-operative rotational laxity indicated a significant correlation at the midflexion range. This study showed that a large preoperative rotational laxity increased the risk of a large post-operative laxity, especially at the initial flexion range in PS-TKA. III.
Cartilage loss patterns within femorotibial contact regions during deep knee bend.
Michael Johnson, J; Mahfouz, Mohamed R
2016-06-14
Osteoarthritis (OA) can alter knee kinematics and stresses. The relationship between cartilage loss in OA and kinematics is unclear, with existing work focusing on static wear and morphology. In this work, femorotibial cartilage maps were coupled with kinematics to investigate the relationship between kinematics and cartilage loss, allowing for more precise treatment and intervention. Cartilage thickness maps were created from healthy and OA subgroups (varus, valgus, and neutral) and mapped to a statistical bone atlas. Video fluoroscopy determined contact regions from 0° to 120° flexion. Varus and valgus subgroups displayed different wear patterns across the range of flexion, with varus knees showing more loss in early flexion and valgus in deeper flexion. For the femur, varus knees had more wear in the medial compartment than neutral or valgus and most wear at both 0° and 20° flexion. In the lateral femoral compartment, the valgus subgroup showed significantly more wear from 20° to 60° flexion as compared to other angles, though varus knees displayed highest magnitude of wear. For the tibia, most medial wear occurred at 0-40° flexion and most lateral occurred after 60° flexion. Knowing more about cartilage changes in OA knees provides insight as to expected wear or stresses on implanted components after arthroplasty. Combining cartilage loss patterns with kinematics allows for pre-surgical intervention and treatments tailored to the patient׳s alignment and kinematics. Reported wear patterns may also serve as a gauge for post-operative loading to be considered when placing implant components. Copyright © 2016. Published by Elsevier Ltd.
Human torque velocity adaptations to sprint, endurance, or combined modes of training
NASA Technical Reports Server (NTRS)
Shealy, M. J.; Callister, R.; Dudley, G. A.; Fleck, S. J.
1992-01-01
We had groups of athletes perform sprint and endurance run training independently or concurrently for 8 weeks to examine the voluntary in vivo mechanical responses to each type of training. Pre- and posttraining angle-specific peak torque during knee extension and flexion were determined at 0, 0.84, 1.65, 2.51, 3.35, 4.19, and 5.03 radian.sec-1 and normalized for lean body mass. Knee extension torque in the sprint-trained group increased across all test velocities, the endurance-trained group increased at 2.51, 3.34, 4.19, and 5.03 radian.sec-1, and the group performing the combined training showed no change at any velocity. Knee flexion torque of the sprint and combined groups decreased at 0.84, 1.65, and 2.51 radian.sec-1. Knee flexion torque in the sprint-trained group also decreased at 0 radian.sec-1 and in the combined group at 3.34 radian.sec-1. Knee flexion torque in the endurance-trained group showed no change at any velocity of contraction. Mean knee flexion:extension ratios across the test velocities significantly decreased in the sprint-trained group. Knee extension endurance during 30 seconds of maximal contractions significantly increased in all groups. Only the sprint-trained group showed a significant increase in endurance of the knee flexors. These data suggest that changes in the voluntary in vivo mechanical characteristics of knee extensor and flexor skeletal muscles are specific to the type of run training performed.
Wünschel, Markus; Wülker, Nikolaus; Müller, Otto
2013-11-01
Females have a higher risk in terms of anterior cruciate ligament injuries during sports than males. Reasons for this fact may be different anatomy and muscle recruitment patterns leading to less protection for the cruciate- and collateral-ligaments. This in vitro study aims to evaluate gender differences in knee joint kinematics and muscle force during weight-bearing knee flexions. Thirty-four human knee specimens (17 females/17 males) were mounted on a dynamic knee simulator. Weight-bearing single-leg knee flexions were performed with different amounts of simulated body weight (BW). Gender-specific kinematics was measured with an ultrasonic motion capture system and different loading conditions were examined. Knee joint kinematics did not show significant differences regarding anteroposterior and medial-lateral movement as well as tibial varus-valgus and internal-external rotation. This applied to all simulated amounts of BW. Simulating 100 N BW in contrast to AF50 led to a significant higher quadriceps overall force in female knees from 45° to 85° of flexion in contrast to BW 50 N. In these female specimens, the quadriceps overall force was about 20 % higher than in male knees being constant in higher flexion angles. It is indicated by our results that in a squatting movement females compared with males produce higher muscle forces, suggesting an increased demand for muscular stabilization, whereas tibio-femoral kinematics was similar for both genders.
Brown, Scott R; Wang, Henry; Dickin, D Clark; Weiss, Kaitlyn J
2014-11-01
This study examined the relationship between leg preference and knee mechanics in females during sidestepping. Three-dimensional data were recorded on 16 female collegiate footballers during a planned 45° sidestep manoeuvre with their preferred and non-preferred kicking leg. Knee kinematics and kinetics during initial contact, weight acceptance, peak push-off, and final push-off phases of sidestepping were analysed in both legs. The preferred leg showed trivial to small increases (ES = 0.19-0.36) in knee flexion angle at initial contact, weight acceptance, and peak push-off, and small increases (ES = 0.21-0.34) in peak power production and peak knee extension velocity. The non-preferred leg showed a trivial increase (ES = 0.10) in knee abduction angle during weight acceptance; small to moderate increases (ES = 0.22-0.64) in knee internal rotation angle at weight acceptance, peak push-off, and final push-off; a small increase (ES = 0.22) in knee abductor moment; and trivial increases (ES = 0.09-0.14) in peak power absorption and peak knee flexion velocity. The results of this study show that differences do exist between the preferred and non-preferred leg in females. The findings of this study will increase the knowledge base of anterior cruciate ligament injury in females and can aid in the design of more appropriate neuromuscular, plyometric, and strength training protocols for injury prevention.
Knee Control and Jump-Landing Technique in Young Basketball and Floorball Players.
Leppänen, M; Pasanen, K; Kulmala, J-P; Kujala, U M; Krosshaug, T; Kannus, P; Perttunen, J; Vasankari, T; Parkkari, J
2016-04-01
Poor knee alignment is associated with increased loading of the joints, ligaments and tendons, and may increase the risk of injury. The study purpose was to compare differences in knee kinematics between basketball and floorball players during a vertical drop jump (VDJ) task. We wanted to investigate whether basketball players, whose sport includes frequent jump-landings, exhibited better knee control compared with floorball players, whose sport involves less jumping. Complete data was obtained from 173 basketball and 141 floorball players. Peak knee valgus and flexion angles during the VDJ were analyzed by 3D motion analysis.Larger knee valgus angles were observed among basketball players (- 3.2°, 95%CI -4.5 to - 2.0) compared with floorball players (- 0.9°, 95%CI -2.3 to 0.6) (P=0.022). Basketball players landed with a decreased peak knee flexion angle (83.1°, 95%CI 81.4 to 84.8) compared with floorball players (86.5°, 95%CI 84.6 to 88.4) (P=0.016). There were no significant differences in height, weight or BMI between basketball and floorball players. Female athletes exhibited significantly greater valgus angles than males. This study revealed that proper knee control during jump-landing does not seem to develop in young athletes simply by playing the sport, despite the fact that jump-landings occur frequently in practice and games. © Georg Thieme Verlag KG Stuttgart · New York.
The Shank-to-Vertical-Angle as a parameter to evaluate tuning of Ankle-Foot Orthoses.
Kerkum, Yvette L; Houdijk, Han; Brehm, Merel-Anne; Buizer, Annemieke I; Kessels, Manon L C; Sterk, Arjan; van den Noort, Josien C; Harlaar, Jaap
2015-09-01
The effectiveness of an Ankle-Foot Orthosis footwear combination (AFO-FC) may be partly dependent on the alignment of the ground reaction force with respect to lower limb joint rotation centers, reflected by joint angles and moments. Adjusting (i.e. tuning) the AFO-FC's properties could affect this alignment, which may be guided by monitoring the Shank-to-Vertical-Angle. This study aimed to investigate whether the Shank-to-Vertical-Angle during walking responds to variations in heel height and footplate stiffness, and if this would reflect changes in joint angles and net moments in healthy adults. Ten subjects walked on an instrumented treadmill and performed six trials while walking with bilateral rigid Ankle-Foot Orthoses. The AFO-FC heel height was increased, aiming to impose a Shank-to-Vertical-Angle of 5°, 11° and 20°, and combined with a flexible or stiff footplate. For each trial, the Shank-to-Vertical-Angle, joint flexion-extension angles and net joint moments of the right leg at midstance were averaged over 25 gait cycles. The Shank-to-Vertical-Angle significantly increased with increasing heel height (p<0.001), resulting in an increase in knee flexion angle and internal knee extensor moment (p<0.001). The stiff footplate reduced the effect of heel height on the internal knee extensor moment (p=0.030), while the internal ankle plantar flexion moment increased (p=0.035). Effects of heel height and footplate stiffness on the hip joint were limited. Our results support the potential to use the Shank-to-Vertical-Angle as a parameter to evaluate AFO-FC tuning, as it is responsive to changes in heel height and reflects concomitant changes in the lower limb angles and moments. Copyright © 2015 Elsevier B.V. All rights reserved.
McGrath, Timothy; Fineman, Richard; Stirling, Leia
2018-06-08
Inertial measurement units (IMUs) have been demonstrated to reliably measure human joint angles—an essential quantity in the study of biomechanics. However, most previous literature proposed IMU-based joint angle measurement systems that required manual alignment or prescribed calibration motions. This paper presents a simple, physically-intuitive method for IMU-based measurement of the knee flexion/extension angle in gait without requiring alignment or discrete calibration, based on computationally-efficient and easy-to-implement Principle Component Analysis (PCA). The method is compared against an optical motion capture knee flexion/extension angle modeled through OpenSim. The method is evaluated using both measured and simulated IMU data in an observational study ( n = 15) with an absolute root-mean-square-error (RMSE) of 9.24∘ and a zero-mean RMSE of 3.49∘. Variation in error across subjects was found, made emergent by the larger subject population than previous literature considers. Finally, the paper presents an explanatory model of RMSE on IMU mounting location. The observational data suggest that RMSE of the method is a function of thigh IMU perturbation and axis estimation quality. However, the effect size for these parameters is small in comparison to potential gains from improved IMU orientation estimations. Results also highlight the need to set relevant datums from which to interpret joint angles for both truth references and estimated data.
Miyake, Tamon; Kobayashi, Yo; Fujie, Masakatsu G; Sugano, Shigeki
2017-07-01
Gait training robots are useful for changing gait patterns and decreasing risk of trip. Previous research has reported that decreasing duration of the assistance or guidance of the robot is beneficial for efficient gait training. Although robotic intermittent control method for assisting joint motion has been established, the effect of the robot intervention timing on change of toe clearance is unclear. In this paper, we tested different timings of applying torque to the knee, employing the intermittent control of a gait training robot to increase toe clearance throughout the swing phase. We focused on knee flexion motion and designed a gait training robot that can apply flexion torque to the knee with a wire-driven system. We used a method of timing detecting for the robot conducting torque control based on information from the hip, knee, and ankle angles to establish a non-time dependent parameter that can be used to adapt to gait change, such as gait speed. We carried out an experiment in which the conditions were four time points: starting the swing phase, lifting the foot, maintaining knee flexion, and finishing knee flexion. The results show that applying flexion torque to the knee at the time point when people start lifting their toe is effective for increasing toe clearance in the whole swing phase.
McGovern, Andrew; Dude, Christopher; Munkley, Daniel; Martin, Thomas; Wallace, David; Feinn, Richard; Dione, Donald; Garbalosa, Juan C
2015-12-01
Despite the recent emphasis on injury prevention, anterior cruciate ligament (ACL) injury rates remain high. This study aimed to ascertain the effects of prolonged activity on lower limb kinematics during a self-selected cutting maneuver. Angular kinematics were recorded during an agility test performed until the completion time was greater than the mean plus one SD of baseline trials. Cut type was identified and the hip and knee angles at 33 ms post heel strike were determined. A linear mixed effects model assessed the effects of cut type, gender, and activity status on the hip and knee angles. Males performed sidestep cuts more frequently than females. Females increased the incidence of sidestep cuts after prolonged activity. At the hip, a gender-cut type interaction existed for the transverse (p=0.001) and sagittal (p=0.11) planes. Females showed more internal rotation during sidestep and more external rotation and less flexion during crossover cuts. For the frontal plane, a gender-activity status interaction (p = 0.032) was due to no change within females but greater hip adduction during prolonged activity within males. With prolonged activity, both genders displayed less hip (p=0.29) and knee (p=0.009) flexion and more knee (p=0.001) adduction. Females displayed less hip and knee flexion than men (p=0.001). Sidestep may be more risky than crossover cuts. Both genders place themselves in at-risk postures with prolonged activity due to less hip and knee flexion. Copyright © 2015 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Zebas, Carole J.
This study focuses on changes occurring in selected mechanical components of high school girls performing the standing broad jump, and collects data pertaining to the effects of monetary reward and videotape feedback upon the following components: (a) distance jumped, (b) maximum angle of knee flexion, (c) maximum angle of hip flexion, (d) hip…
Biomechanics of Hyperflexion and Kneeling before and after Total Knee Arthroplasty
2014-01-01
The capacity to perform certain activities is frequently compromised after total knee arthroplasty (TKA) due to a functional decline resulting from decreased range of motion and a diminished ability to kneel. In this manuscript, the current biomechanical understanding of hyperflexion and kneeling before and after TKA will be discussed. Patellofemoral and tibiofemoral joint contact area, contact pressure, and kinematics were evaluated in cadaveric studies using a Tekscan pressure measuring system and Microscribe. Testing was performed on intact knees and following cruciate retaining and posterior stabilized TKA at knee flexion angles of 90°, 105°, 120°, and 135°. Three loading conditions were used to simulate squatting, double stance kneeling, and single stance kneeling. Following TKA with double stance kneeling, patellofemoral contact areas did not increase significantly at high knee flexion angle (135°). Kneeling resulted in tibial posterior translation and external rotation at all flexion angles. Moving from double to single stance kneeling tended to increase pressures in the cruciate retaining group, but decreased pressures in the posterior stabilized group. The cruciate retaining group had significantly larger contact areas than the posterior stabilized group, although no significant differences in pressures were observed comparing the two TKA designs (p < 0.05). If greater than 120° of postoperative knee range of motion can be achieved following TKA, then kneeling may be performed with less risk in the patellofemoral joint than was previously believed to be the case. However, kneeling may increase the likelihood of damage to cartilage and menisci in intact knees and after TKA increases in tibiofemoral contact area and pressures may lead to polyethyelene wear if performed on a chronic, repetitive basis. PMID:24900891
Biomechanics of hyperflexion and kneeling before and after total knee arthroplasty.
Lee, Thay Q
2014-06-01
The capacity to perform certain activities is frequently compromised after total knee arthroplasty (TKA) due to a functional decline resulting from decreased range of motion and a diminished ability to kneel. In this manuscript, the current biomechanical understanding of hyperflexion and kneeling before and after TKA will be discussed. Patellofemoral and tibiofemoral joint contact area, contact pressure, and kinematics were evaluated in cadaveric studies using a Tekscan pressure measuring system and Microscribe. Testing was performed on intact knees and following cruciate retaining and posterior stabilized TKA at knee flexion angles of 90°, 105°, 120°, and 135°. Three loading conditions were used to simulate squatting, double stance kneeling, and single stance kneeling. Following TKA with double stance kneeling, patellofemoral contact areas did not increase significantly at high knee flexion angle (135°). Kneeling resulted in tibial posterior translation and external rotation at all flexion angles. Moving from double to single stance kneeling tended to increase pressures in the cruciate retaining group, but decreased pressures in the posterior stabilized group. The cruciate retaining group had significantly larger contact areas than the posterior stabilized group, although no significant differences in pressures were observed comparing the two TKA designs (p < 0.05). If greater than 120° of postoperative knee range of motion can be achieved following TKA, then kneeling may be performed with less risk in the patellofemoral joint than was previously believed to be the case. However, kneeling may increase the likelihood of damage to cartilage and menisci in intact knees and after TKA increases in tibiofemoral contact area and pressures may lead to polyethyelene wear if performed on a chronic, repetitive basis.
Intraarticular arthrofibrosis of the knee alters patellofemoral contact biomechanics.
Mikula, Jacob D; Slette, Erik L; Dahl, Kimi D; Montgomery, Scott R; Dornan, Grant J; O'Brien, Luke; Turnbull, Travis Lee; Hackett, Thomas R
2017-12-19
Arthrofibrosis in the suprapatellar pouch and anterior interval can develop after knee injury or surgery, resulting in anterior knee pain. These adhesions have not been biomechanically characterized. The biomechanical effects of adhesions in the suprapatellar pouch and anterior interval during simulated quadriceps muscle contraction from 0 to 90° of knee flexion were assessed. Adhesions of the suprapatellar pouch and anterior interval were hypothesized to alter the patellofemoral contact biomechanics and increase the patellofemoral contact force compared to no adhesions. Across all flexion angles, suprapatellar adhesions increased the patellofemoral contact force compared to no adhesions by a mean of 80 N. Similarly, anterior interval adhesions increased the contact force by a mean of 36 N. Combined suprapatellar and anterior interval adhesions increased the mean patellofemoral contact force by 120 N. Suprapatellar adhesions resulted in a proximally translated patella from 0 to 60°, and anterior interval adhesions resulted in a distally translated patella at all flexion angles other than 15° (p < 0.05). The most important finding in this study was that patellofemoral contact forces were significantly increased by simulated adhesions in the suprapatellar pouch and anterior interval. Anterior knee pain and osteoarthritis may result from an increase in patellofemoral contact force due to patellar and quadriceps tendon adhesions. For these patients, arthroscopic lysis of adhesions may be beneficial.
Isometric hip-rotator torque production at varying degrees of hip flexion.
Johnson, Sam; Hoffman, Mark
2010-02-01
Hip torque production is associated with certain knee injuries. The hip rotators change function depending on hip angle. To compare hip-rotator torque production between 3 angles of hip flexion, limbs, and sexes. Descriptive. University sports medicine research laboratory. 15 men and 15 women, 19-39 y. Three 6-s maximal isometric contractions of the hip external and internal rotators at 10 degrees, 40 degrees, and 90 degrees of hip flexion on both legs. Average torque normalized to body mass. Internal-rotation torque was greatest at 90 degrees of hip flexion, followed by 40 degrees of hip flexion and finally 10 degrees of hip flexion. External-rotation torque was not different based on hip flexion. The nondominant leg's external rotators were stronger than the dominant leg's, but the reverse was true for internal rotators. Finally, the men had more overall rotator torque. Hip-rotation torque production varies between flexion angle, leg, and sex. Clinicians treating lower extremity problems need to be aware of these differences.
Kaur, Mandeep; Ribeiro, Daniel Cury; Theis, Jean-Claude; Webster, Kate E; Sole, Gisela
2016-12-01
Altered gait patterns follow ing anterior cruciate ligament reconstruction (ACLR) may be associated with long-term impairments and post-traumatic osteoarthritis. This systematic review and meta-analysis compared lower limb kinematics and kinetics of the ACL reconstructed knee with (1) the contralateral limb and (2) healthy age-matched participants during walking, stair climbing, and running. The secondary aim was to describe the differences over time following ACLR for these biomechanical variables. Database searches were conducted from inception to July 2014 and updated in August 2015 for studies exploring peak knee angles and moments following ACLR during walking, stair negotiation, and running. Risk of bias was assessed with a modified Downs and Black quality index for all included studies, and meta-analyses were performed. Forest plots were explored qualitatively for recovery of gait variables over time after surgery. A total of 40 studies were included in the review; 26 of these were rated as low risk and 14 as high risk of bias. The meta-analysis included 27 studies. Strong to moderate evidence indicated no significant difference in peak flexion angles between ACLR and control groups during walking and stair ascent. Strong evidence was found for lower peak flexion moments in participants with ACLR compared with control groups and contralateral limb during walking and stair activities. Strong to moderate evidence was found for lower peak adduction moment in ACLR participants for the injured compared with the contralateral limbs during walking and stair descent. The qualitative assessment for recovery over time indicated a pattern towards restoration of peak knee flexion angle with increasing time from post-surgery. Peak knee adduction moments were lower within the first year following surgery and higher than controls during later phases (5 years). Joint kinematics are restored, on average, 6 years following reconstruction, while knee external flexion moments remain lower than controls. Knee adduction moments are lower during early phases following reconstruction, but are higher than controls, on average, 5 years post-surgery. Findings indicate that knee function is not fully restored following reconstruction, and long-term maintenance programs may be needed.
Lin, Kun-Jhih; Huang, Chang-Hung; Liu, Yu-Liang; Chen, Wen-Chuan; Chang, Tsung-Wei; Yang, Chan-Tsung; Lai, Yu-Shu; Cheng, Cheng-Kung
2011-10-01
The post-cam design of contemporary posterior stabilized knee prosthesis can be categorized into flat-on-flat or curve-on-curve contact surfaces. The curve-on-curve design has been demonstrated its advantage of reducing stress concentration when the knee sustained an anteroposterior force with tibial rotation. How the post-cam design affects knee kinematics is still unknown, particularly, to compare the difference between the two design features. Analyzing knee kinematics of posterior stabilized knee prosthesis with various post-cam designs should provide certain instructions to the modification of prosthesis design. A dynamic knee model was utilized to investigate tibiofemoral motion of various post-cam designs during high knee flexion. Two posterior stabilized knee models were constructed with flat-on-flat and curve-on-curve contact surfaces of post-cam. Dynamic data of axial tibial rotation and femoral translation were measured from full-extension to 135°. Internal tibial rotation increased with knee flexion in both designs. Before post-cam engagement, the magnitude of internal tibial rotation was close in the two designs. However, tibial rotation angle decreased beyond femoral cam engaged with tibial post. The rate of reduction of tibial rotation was relatively lower in the curve-on-curve design. From post-cam engagement to extreme flexion, the curve-on-curve design had greater internal tibial rotation. Motion constraint was generated by medial impingement of femoral cam on tibial post. It would interfere with the axial motion of the femur relative to the tibia, resulting in decrease of internal tibial rotation. Elimination of rotational constraint should be necessary for achieving better tibial rotation during high knee flexion. Copyright © 2011 Elsevier Ltd. All rights reserved.
Zhu, Zhonglin; Ding, Hui; Dang, Xiao; Tang, Jing; Zhou, Yixin; Wang, Guangzhi
2010-01-01
Fixed-bearing posterior-stabilized (PS) total knee arthroplasty (TKA) has been used in Asian countries for several years, but few studies have investigated differences in the kinematic properties of the patellar tendon after standard PS TKA as compared to high-flex PS TKA. To quantify the in vitro three-dimensional (3D) kinematics of the patellar tendon during passive high flexion and full extension before and after two different types of PS TKAs. Six fresh-frozen cadaveric knees were tested under the following conditions: the unaltered state, status-post traditional PS prostheses (Simth-nephew GENESIS II) replacement, and status-post high-flexion PS prostheses replacement. The soft tissue around the knee and the quadriceps muscle were preserved, then tested under the load of a specific weight in an Oxford knee rig. We designed a specialized rigid body with four active markers fixed to each bone to track the 3D passive motion of the cadaveric knees. Flexion and extension was controlled by the knee rig and captured by an Optotrak Certus high precision optical tracking system. The attachment sites of the patellar tendon were registered as virtual markers to calculate the 3D kinematics. The patellar tendon of the unaltered knee and both TKA knees showed similar deformation. We found the length of the patellar tendon changed significantly during a motion from full extension to 30°, but there was no significant change in length while undergoing a motion from 30° to full flexion. Both the sagittal plane and coronal plane angles of the patellar tendon decreased after PS TKAs. There was no significant difference in patellar tendon kinematics between the two types of PS TKAs. We believe the changes observed in the sagittal plane and coronal plane angles of the patellar tendon after PS TKAs may influence the extensor mechanism and be an important cause of patella-femoral complications. These data may be used to assess patella-femoral complications after surgery so as to improve the design of high-flexion TKAs for Asians and achieve long-term stability.
Gokeler, Alli; Bisschop, Marsha; Myer, Gregory D; Benjaminse, Anne; Dijkstra, Pieter U; van Keeken, Helco G; van Raay, Jos J A M; Burgerhof, Johannes G M; Otten, Egbert
2016-07-01
The purpose of this study was to evaluate the influence of immersion in a virtual reality environment on knee biomechanics in patients after ACL reconstruction (ACLR). It was hypothesized that virtual reality techniques aimed to change attentional focus would influence altered knee flexion angle, knee extension moment and peak vertical ground reaction force (vGRF) in patients following ACLR. Twenty athletes following ACLR and 20 healthy controls (CTRL) performed a step-down task in both a non-virtual reality environment and a virtual reality environment displaying a pedestrian traffic scene. A motion analysis system and force plates were used to measure kinematics and kinetics during a step-down task to analyse each single-leg landing. A significant main effect was found for environment for knee flexion excursion (P = n.s.). Significant interaction differences were found between environment and groups for vGRF (P = 0.004), knee moment (P < 0.001), knee angle at peak vGRF (P = 0.01) and knee flexion excursion (P = 0.03). There was larger effect of virtual reality environment on knee biomechanics in patients after ACLR compared with controls. Patients after ACLR immersed in virtual reality environment demonstrated knee joint biomechanics that approximate those of CTRL. The results of this study indicate that a realistic virtual reality scenario may distract patients after ACLR from conscious motor control. Application of clinically available technology may aid in current rehabilitation programmes to target altered movement patterns after ACLR. Diagnostic study, Level III.
McCarthy, Moira M.; Tucker, Scott; Nguyen, Joseph T.; Green, Daniel W.; Imhauser, Carl W.; Cordasco, Frank A.
2014-01-01
Background Anterior cruciate ligament (ACL) injuries are an increasingly recognized problem in the pediatric population. Unfortunately, outcomes with conservative treatment are extremely poor. Furthermore, adult reconstruction techniques may be inappropriate to treat skeletally immature patients due to the risk of physeal complications. “Physeal-sparing” reconstruction techniques exist but their ability to restore knee stability and contact mechanics is not well understood. Purpose (1) To assess the ability of the all-epiphyseal (AE) and over-the-top (OT) reconstructions to restore knee kinematics; (2) to assess whether these reconstructions decrease the high posterior contact stresses seen with ACL deficiency; (3) to determine whether the AE or OT produce abnormal tibiofemoral contact stresses. Hypothesis The AE reconstruction will restore contact mechanics and kinematics similarly to that of the ACL intact knee. Methods Ten fresh-frozen human cadaveric knees were tested using a robotic manipulator. Tibiofemoral motions were recorded with the ACL intact, after sectioning the ACL, and after both reconstructions in each of the 10 specimens. The AE utilized an all-inside technique with tunnels exclusively within the epiphysis and fixed with suspensory cortical fixation devices. The OT had a central and vertical tibial tunnel with an over-the-top femur position and was fixed with staples and posts on both ends. Anterior stability was assessed with 134N anterior force at 0, 15, 30, 60, and 90° of knee flexion. Rotational stability was assessed with combined 8 Nm and 4 Nm of abduction and internal rotation, respectively, at 5, 15, and 30° of knee flexion. Results Both reconstruction techniques offloaded the posterior aspect of the tibial plateau compared to the ACL deficient knee in response to both anterior loads and combined moments as demonstrated by reduced contact stresses in this region at all flexion angles. Compared to the ACL intact condition, both the AE and OT had increased posteromedial contact stresses in response to anterior load at some flexion angles and the OT had increased peripheral posterolateral contact stresses at 15° in response to combined moments. Neither reconstruction completely restored the mid-joint contact stresses. Both reconstruction techniques restored anterior stability at flexion angles less than or equal to 30°. In contrast, neither reconstruction restored anterior stability at 60 and 90° flexion. Both reconstructions restored coupled anterior translation under combined moments. Additionally, the AE over-constrained internal rotation in response to the combined moments by 12% at 15° flexion. Conclusions Both reconstructions provide anterior and rotational stability, and decrease posterior joint contact stresses compared to the ACL deficient knee. However, neither reconstruction restored the contact mechanics and kinematics of the ACL intact knee. Clinical Relevance Since the AE reconstruction has clinical advantages over the OT, our results support the hypothesis that the new AE technique is a potential candidate for use in the skeletally immature athlete. PMID:23613444
Lauber, Benedikt; Lichtwark, Glen A; Cresswell, Andrew G
2014-06-01
While medial gastrocnemius (MG) and soleus (SOL) are considered synergists, they are anatomically exclusive in that SOL crosses only the ankle, while MG crosses both the knee and ankle. Due to the force-length properties of both active and passive structures, activation of SOL and MG must be constantly regulated to provide the required joint torques for any planned movement. As such, the aim of this study was to investigate the neural regulation of MG and SOL when independently changing their length by changing only the knee joint angle, thus exclusively altering the length of MG fibers. MG and SOL motor units (MU) were recorded intramuscularly along with ultrasound imaging of MG and SOL fascicle lengths, while moving the knee through 60° of rotation and maintaining a low level of voluntary plantar flexor torque. The results showed a reciprocal activation of MG and SOL as the knee was moved into flexion and extension. A clear reduction in MG MU firing rates occurred as the knee was flexed (MG fascicles shortening), with de-recruitment of most MG MU occurring at close to full knee flexion. A concomitant increase in SOL MU activity was observed while no change in the length of its fascicles was found. The opposite effects were found when the knee was moved into extension. A strong correlation (ICC = 0.78) was found between the fascicle length at which MG MUs were de-recruited and subsequently re-recruited. This was stronger than the relationship of de-recruitment and re-recruitment with knee angle (ICC = 0.52), indicating that in this instance, muscle fascicle length rather than joint angle is more influential in regulating MG recruitment. Such a reciprocal arrangement like the one presented here for SOL and MG is essential for human voluntary movements such as walking or cycling. © 2014 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.
Farrow, Lutul D; Parker, Richard D
2010-06-01
Anatomic reconstruction of the anterior cruciate ligament through an accessory medial portal has become increasingly popular. The purpose of this study is to describe the relationship of guide pin exit points to the lateral anatomic structures when preparing the anterior cruciate ligament femoral tunnel through an accessory medial portal. We utilized seven fresh frozen cadaveric knees. Utilizing an anteromedial approach, a guide wire was placed into the center of each bundle's footprint. Each guide wire was advanced through the lateral femoral cortex. The guide pins were passed at 90, 110, and 130 degrees of knee flexion. The distances from each guide pin to the closest relevant structures on the lateral side of the knee were measured. At 90 degrees the posterolateral bundle guide pin was closest to the lateral condyle articular cartilage (mean 5.4 +/- 2.2 mm) and gastrocnemius tendon (mean 5.7 +/- 2.1 mm). At 110 degrees the posterolateral bundle pin was closest to the gastrocnemius tendon (mean 4.5 +/- 3.4 mm). At 130 degrees the posterolateral bundle pin was closest to the gastrocnemius tendon (mean 7.2 +/- 5.5 mm) and lateral collateral ligament (mean 6.8 +/- 2.1 mm). At 90 degrees the anteromedial bundle guide pin was closest to the articular cartilage (mean 2.0 +/- 2.0 mm). At 110 degrees the anteromedial bundle pin was closest to the articular cartilage (mean 7.4 +/- 3.5 mm) and gastrocnemius tendon (mean 12.3 +/- 3.1 mm). At 130 degrees the AM bundle pin was closest to the gastrocnemius tendon (mean 8.2 +/- 3.2 mm) and LCL (mean 15.1 +/- 2.9 mm). Neither guide pin (anteromedial or posterolateral bundle) put the peroneal nerve at risk at any knee flexion angle. At low knee flexion angles the anteromedial and posterolateral bundle guide pins closely approximated multiple lateral structures when using an accessory medial arthroscopic portal. Utilizing higher flexion angles increases the margin of error when preparing both femoral tunnels. During preparation of the anterior cruciate ligament femoral tunnel through an accessory anteromedial portal the tunnels should be drilled in at least 110 degrees of knee flexion in order to move guide pin exit points away from important lateral knee structures.
Rupture of posterior cruciate ligament leads to radial displacement of the medial meniscus.
Zhang, Can; Deng, Zhenhan; Luo, Wei; Xiao, Wenfeng; Hu, Yihe; Liao, Zhan; Li, Kanghua; He, Hongbo
2017-07-11
To explore the association between the rupture of posterior cruciate ligament (PCL) and the radial displacement of medial meniscus under the conditions of different flexion and various axial loads. The radial displacement value of medial meniscus was measured for the specimens of normal adult knee joints, including 12 intact PCLs, 6 ruptures of the anterolateral bundle (ALB), 6 ruptures of the postmedial bundle (PMB), and 12 complete ruptures. The measurement was conducted at 0°, 30°, 60°, and 90° of knee flexion angles under 200 N, 400 N, 600 N, 800 N and 1000 N of axial loads respectively. The displacement values of medial meniscus of the ALB rupture group increased at 0° flexion under 800 N and 1000 N, and at 30°, 60° and 90° flexion under all loads in comparison with the PCL intact group. The displacement values of the PMB rupture group was higher at 0° and 90° flexion under all loads, and at 30° and 60° flexion under 800 N and 1000 N loads. The displacement of the PCL complete rupture group increased at all flexion angles under all loads. Either partial or complete rupture of the PCL can increase in the radial displacement of the medial meniscus, which may explain the degenerative changes that occuring in the medial meniscus due to PCL injury. Therefore, early reestablishment of the PCL is necessarily required in order to maintain stability of the knee joint after PCL injury.
Jang, Sung Won; Koh, In Jun; Kim, Man Soo; Kim, Ju Yeong; In, Yong
2016-11-01
The sequential medial release technique including semimembranosus (semiM) release is effective and safe during varus total knee arthroplasty (TKA). However, there are concerns about weakening of knee flexion strength after semiM release. We determined whether semiM release to balance the medial soft tissue decreased knee flexion strength after TKA. Fifty-nine consecutive varus knees undergoing TKA were prospectively enrolled. A 3-step sequential release protocol which consisted of release of (1) the deep medial collateral ligament (dMCL), (2) the semiM, and (3) the superficial medial collateral ligament based on medial tightness. Gap balancing was obtained after dMCL release in 31 knees. However, 28 knees required semiM release or more after dMCL release. Isometric muscle strength of the knee was compared 6 months postoperatively between the semiM release and semiM nonrelease groups. Knee stability and clinical outcomes were also compared. No differences in knee flexor or extensor peak torque were observed between the groups 6 months postoperatively (P = .322 and P = .383, respectively). No group difference was observed in medial joint opening angle on valgus stress radiographs (P = .327). No differences in the Knee Society or Western Ontario and McMaster Universities Osteoarthritis Index scores were detected between the groups (P = .840 and P = .682, respectively). These results demonstrate that semiM release as a sequential step to balance medial soft tissue in varus knees did not affect knee flexion strength after TKA. Copyright © 2016 Elsevier Inc. All rights reserved.
Manning, William A; Ghosh, Kanishka; Blain, Alasdair; Longstaff, Lee; Deehan, David John
2017-06-01
Accurate soft tissue balance must be achieved to improve functional outcome after total knee arthroplasty (TKA). Sensor-integrated tibial trials have been introduced that allow real-time measurement of tibiofemoral kinematics during TKA. This study examined the interplay between tibiofemoral force and laxity, under defined intraoperative conditions, so as to quantify the kinematic behaviour of the CR femoral single-radius knee. TKA was undertaken in eight loaded cadaveric specimens. Computer navigation in combination with sensor data defined laxity and tibiofemoral contact force, respectively, during manual laxity testing. Fixed-effect linear modelling allowed quantification of the effect for flexion angle, direction of movement and TKA implantation upon the knee. An inverse relationship between laxity and contact force was demonstrated. With flexion, laxity increased as contact force decreased under manual stress. Change in laxity was significant beyond 30° for coronal plane laxity and beyond 60° for rotatory laxity (p < 0.01). Rotational stress in mid-flexion demonstrated the greatest mismatch in inter-compartmental forces. Contact point position over the tibial sensor demonstrated paradoxical roll-forward with knee flexion. Traditional balancing techniques may not reliably equate to uniform laxity or contact forces across the tibiofemoral joint through a range of flexion and argue for the role of per-operative sensor use to aid final balancing of the knee.
Ithurburn, Matthew P; Paterno, Mark V; Ford, Kevin R; Hewett, Timothy E; Schmitt, Laura C
2015-11-01
Young athletes who have had anterior cruciate ligament (ACL) reconstruction demonstrate suboptimal rates of return to sport, high rates of second ACL injuries, and persistent movement asymmetries. Therefore, the influence of musculoskeletal impairments on movement mechanics in this population needs to be further evaluated. The primary hypothesis was that among young athletes who have had ACL reconstruction, those with greater quadriceps strength asymmetry would demonstrate altered single-leg drop-landing mechanics at return to sport compared with individuals with more symmetric quadriceps strength and also compared with healthy controls (ie, those with no ACL reconstruction). A second hypothesis was that quadriceps strength symmetry would predict single-leg drop-landing symmetry in individuals who have undergone ACL reconstruction. Controlled laboratory study. The study entailed a total of 103 participants (age, 17.4 years) at the time of return to sport after ACL reconstruction and 47 control participants (age, 17.0 years). The quadriceps index (QI) was calculated for isometric quadriceps strength, which was then used to divide the ACL reconstruction participants into high-quadriceps (QI ≥90%; n = 52) and low-quadriceps (QI <85%; n = 41) subgroups. Biomechanical data were collected by use of 3-dimensional motion analysis during a single-leg drop-landing task. The LSI was calculated for kinematic and kinetic sagittal-plane variables of interest during landing. Group differences were compared by use of 1-way analysis of variance and linear regression analyses (α < .05). Both the low- and high-quadriceps groups demonstrated greater limb asymmetry during landing compared with the control group in knee flexion excursion (mean LSI ± SD: low quadriceps, 85.8% ± 15.5% [P < .001]; high quadriceps, 94.2% ± 15.6% [P = .019]; control, 102.7% ± 14.1%), peak trunk flexion angle (low quadriceps, 129.2% ± 36.6% [P < .001]; high quadriceps, 110.5% ± 22.6% [P = .03]; control, 95.5% ± 26.2%), and peak knee extension moment (low quadriceps, 79.5% ± 25.2% [P < .001]; high quadriceps, 89.9% ± 19.8% [P = .005]; control, 102.2% ± 10.9%). Compared with the high-quadriceps group, the low-quadriceps group also demonstrated greater asymmetry during landing in knee flexion excursion (P = .026), peak trunk flexion angle (P = .006), and peak knee extension moment (P = .034). In the ACL reconstruction group, quadriceps strength symmetry predicted symmetry in knee flexion excursion, peak trunk flexion, and peak knee extension moment (all P < .001) and predicted symmetry in peak trunk flexion angle (P < .001) after controlling for graft type, knee-related pain, function with activities of daily living, and sport function. At the time of return to sport, athletes who had undergone ACL reconstruction, including those in both the high- and low-quadriceps groups, demonstrated asymmetry during a single-leg drop-landing task compared with controls. Compensations included increased trunk flexion, decreased knee flexion excursion, and decreased knee extension moments on the involved limb. In addition, individuals in the low-quadriceps group demonstrated greater movement asymmetry compared with individuals in the high-quadriceps group. Restoration of symmetric quadriceps strength after ACL reconstruction is associated with more symmetric mechanics during a single-leg drop-landing movement. However, this appears to be multifactorial, as the high-quadriceps group also demonstrated landing asymmetries. Restoration of symmetric quadriceps strength may improve postoperative athletic participation; however, future study is warranted. © 2015 The Author(s).
Body size and lower limb posture during walking in humans.
Hora, Martin; Soumar, Libor; Pontzer, Herman; Sládek, Vladimír
2017-01-01
We test whether locomotor posture is associated with body mass and lower limb length in humans and explore how body size and posture affect net joint moments during walking. We acquired gait data for 24 females and 25 males using a three-dimensional motion capture system and pressure-measuring insoles. We employed the general linear model and commonality analysis to assess the independent effect of body mass and lower limb length on flexion angles at the hip, knee, and ankle while controlling for sex and velocity. In addition, we used inverse dynamics to model the effect of size and posture on net joint moments. At early stance, body mass has a negative effect on knee flexion (p < 0.01), whereas lower limb length has a negative effect on hip flexion (p < 0.05). Body mass uniquely explains 15.8% of the variance in knee flexion, whereas lower limb length uniquely explains 5.4% of the variance in hip flexion. Both of the detected relationships between body size and posture are consistent with the moment moderating postural adjustments predicted by our model. At late stance, no significant relationship between body size and posture was detected. Humans of greater body size reduce the flexion of the hip and knee at early stance, which results in the moderation of net moments at these joints.
Cuéllar, Vanessa G; Martinez, Danny; Immerman, Igor; Oh, Cheongeun; Walker, Peter S; Egol, Kenneth A
2015-07-01
Although the posteromedial fragment in tibial plateau fractures is often considered unstable, biomechanical evidence supporting this view is lacking. We aimed to evaluate the stability of the fragment in a cadaver model. Our hypothesis was that under the expected small axial force during rehabilitation and the combined effects of this force with shear force, internal rotation torque, and varus moment, the most common posteromedial tibial fragment morphology could maintain stability in early flexion. Axial compression force alone or combined with posterior shear, internal rotation torque, or varus moment was applied to the femurs of 5 fresh cadaveric knees. A Tekscan pressure mapping system was used to measure pressure and contact area between the femoral condyles, meniscus, and tibial plateau. A Microscribe 3D digitizer was used to define the 3-dimensional positions of the femur and tibia. A 10-mm and then a 20-mm osteotomy was created with a saw at an angle of 30 degrees in the axial plane with respect to the tangent of the posterior tibial plateau and 75 degrees in the sagittal plane, representing a typical posteromedial fracture fragment. At each flexion angle (15, 30, 60, 90, and 120 degrees) and loading condition (axial compression only, compression with shear force, torque, and varus moment), distal displacement of the medial femoral condyle and the tibial fracture fragments was determined. For the 10-mm fragment, medial femoral condyle displacement was little affected up to approximately 30-degree flexion, after which it increased. For the 20-mm fragment, there was progressive medial femoral condyle displacement with increasing flexion from baseline. However, for the 10- and 20-mm fragments themselves, displacements were noted at every flexion angle, starting at 1.7 mm inferior displacement with 15 degrees of flexion and internal rotation torque and up to 10.2 mm displacement with 90 degrees of flexion and varus bending moment. In this cadaveric model of a posteromedial tibial plateau fracture, both fracture fragments studied displaced with knee flexion, even at low flexion angles. Although such fragments may initially seem nondisplaced after injury, posteromedial fragments similar to these tested are likely to displace during knee range of motion exercises in non-weight-bearing conditions.
Schmalz, Thomas; Pröbsting, Eva; Auberger, Roland; Siewert, Gordon
2016-04-01
The microprocessor-controlled leg orthosis C-Brace enables patients with paretic or paralysed lower limb muscles to use dampened knee flexion under weight-bearing and speed-adapted control of the swing phase. The objective of the present study was to investigate the new technical functions of the C-Brace orthosis, based on biomechanical parameters. The study enrolled six patients. The C-Brace orthosis is compared with conventional leg orthoses (four stance control orthoses, two locked knee-ankle-foot orthoses) using biomechanical parameters of level walking, descending ramps and descending stairs. Ground reaction forces, joint moments and kinematic parameters were measured for level walking as well as ascending and descending ramps and stairs. With the C-Brace, a nearly natural stance phase knee flexion was measured during level walking (mean value 11° ± 5.6°). The maximum swing phase knee flexion angle of the C-Brace approached the normal value of 65° more closely than the stance control orthoses (66° ± 8.5° vs 74° ± 6.4°). No significant differences in the joint moments were found between the C-Brace and stance control orthosis conditions. In contrast to the conventional orthoses, all patients were able to ambulate ramps and stairs using a step-over-step technique with C-Brace (flexion angle 64.6° ± 8.2° and 70.5° ± 12.4°). The results show that the functions of the C-Brace for situation-dependent knee flexion under weight bearing have been used by patients with a high level of confidence. The functional benefits of the C-Brace in comparison with the conventional orthotic mechanisms could be demonstrated most clearly for descending ramps and stairs. The C-Brace orthosis is able to combine improved orthotic function with sustained orthotic safety. © The International Society for Prosthetics and Orthotics 2014.
Acute Lower Extremity Running Kinematics After a Hamstring Stretch
Davis Hammonds, Autumn L.; Laudner, Kevin G.; McCaw, Steve; McLoda, Todd A.
2012-01-01
Context: Limited passive hamstring flexibility might affect kinematics, performance, and injury risk during running. Pre-activity static straight-leg raise stretching often is used to gain passive hamstring flexibility. Objective: To investigate the acute effects of a single session of passive hamstring stretching on pelvic, hip, and knee kinematics during the swing phase of running. Design: Randomized controlled clinical trial. Setting: Biomechanics research laboratory. Patients or Other Participants: Thirty-four male (age = 21.2 ± 1.4 years) and female (age = 21.3±2.0 years) recreational athletes. Intervention(s): Participants performed treadmill running pretests and posttests at 70% of their age-predicted maximum heart rate. Pelvis, hip, and knee joint angles during the swing phase of 5 consecutive gait cycles were collected using a motion analysis system. Right and left hamstrings of the intervention group participants were passively stretched 3 times for 30 seconds in random order immediately after the pretest. Control group participants performed no stretching or movement between running sessions. Main Outcome Measure(s): Six 2-way analyses of variance to determine joint angle differences between groups at maximum hip flexion and maximum knee extension with an α level of .008. Results: Flexibility increased between pretest and post-test in all participants (F1,30 = 80.61, P<.001). Anterior pelvic tilt (F1,30 = 0.73, P=.40), hip flexion (F1,30 = 2.44, P=.13), and knee extension (F1,30 = 0.06, P=.80) at maximum hip flexion were similar between groups throughout testing. Anterior pelvic tilt (F1,30 = 0.69, P=.41), hip flexion (F1,30 = 0.23, P=.64), and knee extension (F1,30 = 3.38, P=.62) at maximum knee extension were similar between groups throughout testing. Men demonstrated greater anterior pelvic tilt than women at maximum knee extension (F1,30 = 13.62, P=.001). Conclusions: A single session of 3 straight-leg raise hamstring stretches did not change pelvis, hip, or knee running kinematics. PMID:22488225
Pfile, Kate R.; Hart, Joseph M.; Herman, Daniel C.; Hertel, Jay; Kerrigan, D. Casey; Ingersoll, Christopher D.
2013-01-01
Context: Anterior cruciate ligament (ACL) injuries are common in female athletes and are related to poor neuromuscular control. Comprehensive neuromuscular training has been shown to improve biomechanics; however, we do not know which component of neuromuscular training is most responsible for the changes. Objective: To assess the efficacy of either a 4-week core stability program or plyometric program in altering lower extremity and trunk biomechanics during a drop vertical jump (DVJ). Design: Cohort study. Setting: High school athletic fields and motion analysis laboratory. Patients or Other Participants: Twenty-three high school female athletes (age = 14.8 ± 0.8 years, height = 1.7 ± 0.07 m, mass = 57.7 ± 8.5 kg). Intervention(s): Independent variables were group (core stability, plyometric, control) and time (pretest, posttest). Participants performed 5 DVJs at pretest and posttest. Intervention participants engaged in a 4-week core stability or plyometric program. Main Outcome Measure(s): Dependent variables were 3-dimensional hip, knee, and trunk kinetics and kinematics during the landing phase of a DVJ. We calculated the group means and associated 95% confidence intervals for the first 25% of landing. Cohen d effect sizes with 95% confidence intervals were calculated for all differences. Results: We found within-group differences for lower extremity biomechanics for both intervention groups (P ≤ .05). The plyometric group decreased the knee-flexion and knee internal-rotation angles and the knee-flexion and knee-abduction moments. The core stability group decreased the knee-flexion and knee internal-rotation angles and the hip-flexion and hip internal-rotation moments. The control group decreased the knee external-rotation moment. All kinetic changes had a strong effect size (Cohen d > 0.80). Conclusions: Both programs resulted in biomechanical changes, suggesting that both types of exercises are warranted for ACL injury prevention and should be implemented by trained professionals. PMID:23768121
Yosmaoğlu, Hayri Baran; Baltacı, Gül; Sönmezer, Emel; Özer, Hamza; Doğan, Deha
2017-12-01
This study aims to compare the effects of anterior cruciate ligament (ACL) reconstruction using autogenous hamstring or patellar tendon graft on the peak torque angle. The study included 132 patients (103 males, 29 females; mean age 29±9 year) who were performed ACL reconstruction with autogenous hamstring or patellar tendon graft. The peak torque angles in the quadriceps and hamstring muscles were recorded using an isokinetic dynamometer. Angle of peak knee flexion torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the hamstring tendon group. Angle of peak knee extension torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the patellar tendon group. There were no statistically significant differences in the flexion and extension peak torque angles between the operated and nonoperated knees at 60°/second in both groups. The angle of peak torque at relatively high angular velocities is affected after ACL reconstruction in patients with hamstring or patellar tendon grafts. The graft donor site directly influences this parameter. This finding may be important for clinicians in terms of preventing re-injury.
Kingston, David C; Acker, Stacey M
2018-01-23
In high knee flexion, contact between the posterior thigh and calf is expected to decrease forces on tibiofemoral contact surfaces, therefore, thigh-calf contact needs to be thoroughly characterized to model its effect. This study measured knee angles and intersegmental contact parameters in fifty-eight young healthy participants for six common high flexion postures using motion tracking and a pressure sensor attached to the right thigh. Additionally, we introduced and assessed the reliability of a method for reducing noise in pressure sensor output. Five repetitions of two squatting, two kneeling, and two unilateral kneeling movements were completed. Interactions of posture by sex occurred for thigh-calf and heel-gluteal center of force, and thigh-calf contact area. Center of force in thigh-calf regions was farther from the knee joint center in females, compared to males, during unilateral kneeling (82 and 67 mm respectively) with an inverted relationship in the heel-gluteal region (331 and 345 mm respectively), although caution is advised when generalizing these findings from a young, relatively fit sample to a population level. Contact area was larger in females when compared to males (mean of 155.61 and 137.33 cm 2 across postures). A posture main effect was observed in contact force and sex main effects were present in onset and max angle. Males had earlier onset (121.0°) and lower max angle (147.4°) with onset and max angles having a range between movements of 8° and 3° respectively. There was a substantial total force difference of 139 N between the largest and smallest activity means. Force parameters measured in this study suggest that knee joint contact models need to incorporate activity-specific parameters when estimating loading. Copyright © 2017 Elsevier Ltd. All rights reserved.
Roth, Joshua D; Howell, Stephen M; Hull, Maury L
2015-10-21
Gap-balancing is an alignment method for total knee arthroplasty with the goal of creating uniform tension in the periarticular soft-tissue restraints and equal laxities throughout the arc of flexion. However, there is little evidence that achieving equal laxities prevents either overly tight or overly loose soft-tissue restraints after total knee arthroplasty. Accordingly, the purpose of the present study was to determine whether the laxities at 0°, 45°, and 90° of flexion are equal in the native knee. Seven different laxities were measured at 0°, 45°, and 90° of flexion in ten fresh-frozen native cadaveric knees (with intact menisci, cartilage, and ligaments) by applying loads of ±5 Nm in varus-valgus rotation, ±3 Nm in internal-external rotation, 100 N in distraction, and ±45 N in anterior-posterior translation with use of a six-degrees-of-freedom load application system. The mean laxities (and standard deviations) at 45° of flexion were 1.7° ± 0.6° greater in varus, 0.9° ± 0.4° greater in valgus, 10.2° ± 2.7° greater in internal rotation, 10.1° ± 2.0° greater in external rotation, 1.7 ± 1.0 mm greater in distraction translation, and 3.3 ± 1.5 mm greater in anterior translation than those at 0° of flexion. The mean laxities at 90° of flexion were 2.5° ± 0.8° greater in varus, 1.0° ± 0.5° greater in valgus, 10.0° ± 4.6° greater in internal rotation, 10.1° ± 4.5° greater in external rotation, 1.8 ± 0.7 mm greater in distraction, and 1.6 ± 1.2 mm greater in anterior translation than those at 0° of flexion. The mean anterior translation at 90° of flexion was 1.7 ± 0.9 mm less than that at 45° of flexion. Because five of the seven laxities were at least 1.7° or 1.6 mm greater at both 45° and 90° of flexion than those at 0° of flexion, the laxities of the native knee measured in this study are unequal at these flexion angles and therefore do not support the goal of gap-balancing in total knee arthroplasty. One possible disadvantage of changing the native laxities at 45° and 90° of flexion to match those at 0° of flexion in a total knee arthroplasty is the overly tight soft-tissue restraints relative to those of the native knee, which patients may perceive as pain, stiffness, and/or limited flexion. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.
Chung, Kyu Sung; Choi, Choong Hyeok; Bae, Tae Soo; Ha, Jeong Ku; Jun, Dal Jae; Wang, Joon Ho; Kim, Jin Goo
2018-04-01
To compare tibiofemoral contact mechanics after fixation for medial meniscus posterior root radial tears (MMPRTs). Seven fresh knees from mature pigs were used. Each knee was tested under 5 conditions: normal knee, MMPRT, pullout fixation with simple sutures, fixation with modified Mason-Allen sutures, and all-inside fixation using Fastfix 360. The peak contact pressure and contact surface area were evaluated using a capacitive sensor positioned between the meniscus and tibial plateau, under a 1,000-N compression force, at different flexion angles (0°, 30°, 60°, and 90°). The peak contact pressure was significantly higher in MMPRTs than in normal knees (P = .018). Although the peak contact pressure decreased significantly after fixation at all flexion angles (P = .031), it never recovered to the values noted in the normal meniscus. No difference was observed among fixation groups (P = .054). The contact surface area was significantly lower in MMPRTs than in the normal meniscus (P = .018) and increased significantly after fixation at all flexion angles (P = .018) but did not recover to within normal limits. For all flexion angles except 60°, the contact surface area was significantly higher for fixation with Mason-Allen sutures than for fixation with simple sutures or all-inside fixation (P = .027). At 90° of flexion, the contact surface area was significantly better for fixation with simple sutures than for all-inside fixation (P = .031). The peak contact pressure and contact surface area improved significantly after fixation, regardless of the fixation method, but did not recover to the levels noted in the normal meniscus after any type of fixation. Among the fixation methods evaluated in this time 0 study, fixation using modified Mason-Allen sutures provided a superior contact surface area compared with that noted after fixation using simple sutures or all-inside fixation, except at 60° of flexion. However, this study had insufficient power to accurately detect the differences between the outcomes of various fixation methods. Our results in a porcine model suggest that fixation can restore tibiofemoral contact mechanics in MMPRT and that fixation with a locking mechanism leads to superior biomechanical properties. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Bakırhan, Serkan; Unver, Bayram; Karatosun, Vasfi
2013-01-01
The study aims to determine body weight ratios between extremities in patients with unilateral total knee arthroplasty (TKA) at 12 months postoperatively at the static-standing position at 30, 60 and 90 degrees of knee flexion. The study included 52 female patients (mean age 65.6±10.6 years; range 40 to 83 years) who underwent unilateral primary TKA. The force-platform was used to calculate the body-weight ratios of the patients. Body weight ratios on the operated and non-operated limbs of the unilateral TKA patients were examined at standing-static position at 30, 60 and 90 degrees of knee flexion on the force-platform according to their age and body mass index (BMI). The pain levels of the patients were evaluated using the visual analog scale. It was found that unilateral TKA patients placed their body weight on the non-operated limb more at the standing-static position, and 30, 60 and 90 degrees of knee flexion at 12 months postoperatively (p<0.05). It was also found that as the knee flexion degree increased with age, so did TKA patients place their body weight on the nonoperated limb more (p<0.05), and that BMI had no effect on the load distribution difference over the two extremities (p>0.05). During the postoperative period, load asymmetry between the two extremities in patients with unilateral TKA remains the same due to advancing age. This accelerates the osteoarthritis process on the non-operated knee. It is concluded that the age factor should be taken into account while planning physiotherapy and rehabilitation programs for unilateral TKA patients and knee exercise programs aiming to place load over the operated limb should be arranged.
Dai, Boyi; Garrett, William E; Gross, Michael T; Padua, Darin A; Queen, Robin M; Yu, Bing
2015-02-01
Anterior cruciate ligament injuries (ACL) commonly occur during jump landing and cutting tasks. Attempts to land softly and land with greater knee flexion are associated with decreased ACL loading. However, their effects on performance are unclear. Attempts to land softly will decrease peak posterior ground-reaction force (PPGRF) and knee extension moment at PPGRF compared with a natural landing during stop-jump and side-cutting tasks. Attempts to land with greater knee flexion at initial ground contact will increase knee flexion at PPGRF compared with a natural landing during both tasks. In addition, both landing techniques will increase stance time and lower extremity mechanical work as well as decrease jump height and movement speed compared with a natural landing during both tasks. Controlled laboratory study. A total of 18 male and 18 female recreational athletes participated in the study. Three-dimensional kinematic and kinetic data were collected during stop-jump and side-cutting tasks under 3 conditions: natural landing, soft landing, and landing with greater knee flexion at initial ground contact. Attempts to land softly decreased PPGRF and knee extension moment at PPGRF compared with a natural landing during stop-jump tasks. Attempts to land softly decreased PPGRF compared with a natural landing during side-cutting tasks. Attempts to land with greater knee flexion at initial ground contact increased knee flexion angle at PPGRF compared with a natural landing during both stop-jump and side-cutting tasks. Attempts to land softly and land with greater knee flexion at initial ground contact increased stance time and lower extremity mechanical work, as well as decreased jump height and movement speed during both stop-jump and side-cutting tasks. Although landing softly and landing with greater knee flexion at initial ground contact may reduce ACL loading during stop-jump and side-cutting tasks, the performance of these tasks decreased, as indicated by increased stance time and mechanical work as well as decreased jump height and movement speed. Training effects tested in laboratory environments with the focus on reducing ACL loading may be reduced in actual competition environments when the focus is on athlete performance. The effects of training programs for ACL injury prevention on lower extremity biomechanics in athletic tasks may need to be evaluated in laboratories as well as in actual competitions. © 2014 The Author(s).
Soft-tissue tension total knee arthroplasty.
Asano, Hiroshi; Hoshino, Akiho; Wilton, Tim J
2004-08-01
It is far from clear how best to define the proper strength of soft-tissue tensioning in total knee arthroplasty (TKA). We attached a torque driver to the Monogram balancer/tensor device and measured soft-tissue tension in full extension and 90 degrees flexion during TKA. In our surgical procedure, when we felt proper soft-tissue tension was being applied, the mean distraction force was noted to be 126N in extension and 121N in flexion. There was no significant correlation between soft-tissue tension and the postoperative flexion angle finally achieved. To the best of our knowledge, this is the first study to assess the actual distraction forces in relation to soft-tissue tension in TKA. Further study may reveal the most appropriate forces to achieve proper soft-tissue tension in the wide variety of circumstances presenting at knee arthroplasty.
Anderson, Dennis E; Madigan, Michael L; Nussbaum, Maury A
2007-01-01
Measurements of human strength can be important during analyses of physical activities. Such measurements have often taken the form of the maximum voluntary torque at a single joint angle and angular velocity. However, the available strength varies substantially with joint position and velocity. When examining dynamic activities, strength measurements should account for these variations. A model is presented of maximum voluntary joint torque as a function of joint angle and angular velocity. The model is based on well-known physiological relationships between muscle force and length and between muscle force and velocity and was tested by fitting it to maximum voluntary joint torque data from six different exertions in the lower limb. Isometric, concentric and eccentric maximum voluntary contractions were collected during hip extension, hip flexion, knee extension, knee flexion, ankle plantar flexion and dorsiflexion. Model parameters are reported for each of these exertion directions by gender and age group. This model provides an efficient method by which strength variations with joint angle and angular velocity may be incorporated into comparisons between joint torques calculated by inverse dynamics and the maximum available joint torques.
Mortazavi, S M J; Heidari, P; Esfandiari, H; Motamedi, M
2008-01-01
Flexion deformity of the haemophilic knee is a considerable cause of disability and may need to be managed surgically in severe cases. We have used a trapezoid supracondylar femoral extension osteotomy to correct severe knee flexion deformity. Nine severe haemophilic patients with contractures >30 degrees that were unresponsive to conservative measures underwent 11 trapezoid osteotomies. The angle of deformity was measured using anteroposterior and lateral knee X-ray films at maximum extension. Factor levels of 80-100% were achieved before the operation. A trapezoid osteotomy of the distal femur bone was performed using a lateral approach. The frontal plane angular deformity (if any) was corrected at the same time. The osteotomy site was fixed using an Arbeitsgemeinschaft für Osteo synthesefragen (AO) condylar blade plate. Following surgery, the knee was supported by a plaster splint at 20 degrees of flexion. Physiotherapy was started on third postoperative day and continued three times a week. There was no serious complication. The deformities were corrected in all of the patients and the mean range of motion increased form 68.6 degrees to 98.1 degrees . Bleeding episodes decreased in all four knees which had a bleeding score of 3 before surgery. Using the Orthopaedic Advisory Committee of the World Federation of Haemophilia scores, nine good and two fair results were obtained. All patients regained the ability to walk for both short and long distance without any aid, climb the stairs, bath, and use public transportation. Trapezoid supracondylar femoral extension osteotomy should be considered in the surgical management of severe haemophilic flexion deformity of the knee joint.
Mehta, Saurabh; Szturm, Tony; El-Gabalawy, Hani S.
2011-01-01
ABSTRACT Purpose: The objective of this study was to examine the effects of intra-articular corticosteroid injection (ICI) on ipsilateral knee flexion/extension, ankle dorsiflexion/plantarflexion (DF/PF), and hip abduction/adduction (abd/add) during stance phase in people with an acute exacerbation of rheumatoid arthritis (RA) of the knee joint. The study also assessed the effects of ICI on spatiotemporal parameters of gait and functional status in this group. Methods: Nine people with an exacerbation of RA of the knee were recruited. Kinematic and spatiotemporal gait parameters were obtained for each participant. Knee-related functional status was assessed using the Knee injury and Osteoarthritis Outcome Score (KOOS). Spatiotemporal gait parameters and joint angles (knee flexion, ankle DF/PF, hip abd/add) of the affected side were compared pre- and post-ICI. Results: Data for eight people were available for analysis. Median values for knee flexion and ankle PF increased significantly following ICI. Gait parameters of cadence, velocity, bilateral stride length, bilateral step length, step width, double-support percentage, and step time on the affected side also showed improvement. Pain and knee-related functional status as measured by the KOOS showed improvement. Conclusions: This study demonstrated a beneficial short-term effect of ICI on knee-joint movements, gait parameters, and knee-related functional status in people with acute exacerbation of RA of the knee. PMID:22942516
Valgus-varus motion of the knee in normal level walking and stair climbing.
Yu, B; Stuart, M J; Kienbacher, T; Growney, E S; An, K-N
1997-07-01
OBJECTIVE: The knee valgus-varus moment and the knee angles were compared between normal level walking and stair climbing. DESIGN: Ten healthy subjects were tested for ascent, descent, and level walking. BACKGROUND: An understanding of the normal valgus-varus motion of the knee during stair climbing is needed to apply biomechanical analysis of stair climbing as a evaluation tool for knee osteoarthritis patients. METHODS: A motion analysis system, three force plates, and a flight of stairs were used to collect kinematic and kinetic data. The knee angles and moments were calculated from the collected kinematic and kinetic data. RESULTS: The knee varus angle for the maximum knee valgus moments in stair climbing was significantly greater than that in level walking. The knee valgus moment was significantly correlated to ground reaction forces and knee valgus-varus angle during stair climbing and level walking. CONCLUSIONS: There is a coupling between the knee valgus-varus motion and flexion-extension motion. Ground reaction forces are the major contributors to the within-subject variation in the knee valgus-varus moment during stair climbing and level walking. The knee valgus-varus angle is a major contributor to the between-subject variation in the knee valgus moment during stair climbing and level walking.
Influence of trunk posture on lower extremity energetics during running.
Teng, Hsiang-Ling; Powers, Christopher M
2015-03-01
This study aimed to examine the influence of sagittal plane trunk posture on lower extremity energetics during running. Forty asymptomatic recreational runners (20 males and 20 females) ran overground at a speed of 3.4 m·s(-1). Sagittal plane trunk kinematics and lower extremity kinematics and energetics during the stance phase of running were computed. Subjects were dichotomized into high flexion (HF) and low flexion (LF) groups on the basis of the mean trunk flexion angle. The mean (±SD) trunk flexion angles of the HF and LF groups were 10.8° ± 2.2° and 3.6° ± 2.8°, respectively. When compared with the LF group, the HF group demonstrated significantly higher hip extensor energy generation (0.12 ± 0.06 vs 0.05 ± 0.04 J·kg(-1), P < 0.001) and lower knee extensor energy absorption (0.60 ± 0.14 vs 0.74 ± 0.09 J·kg(-1), P = 0.001) and generation (0.30 ± 0.05 vs 0.34 ± 0.06 J·kg(-1), P = 0.02). There was no significant group difference for the ankle plantarflexor energy absorption or generation (P > 0.05). Sagittal plane trunk flexion has a significant influence on hip and knee energetics during running. Increasing forward trunk lean during running may be used as a strategy to reduce knee loading without increasing the biomechanical demand at the ankle plantarflexors.
Myers, Casey A.; Torry, Michael R.; Peterson, Daniel S.; Shelburne, Kevin B.; Giphart, J. Erik; Krong, Jacob P.; Woo, Savio L-Y.; Steadman, J. Richard
2014-01-01
Background Previous laboratory studies of landing have defined landing techniques in terms of soft or stiff landings according to the degree of maximal knee flexion angle attained during the landing phase and the relative magnitude of the ground-reaction force. Current anterior cruciate ligament injury prevention programs are instructing athletes to land softly to avoid excessive strain on the anterior cruciate ligament. Purpose This study was undertaken to measure, describe, and compare tibiofemoral rotations and translations of soft and stiff landings in healthy individuals using biplane fluoroscopy. Study Design Controlled laboratory study. Methods The in vivo, lower extremity, 3-dimensional knee kinematics of 16 healthy adults (6 male and 10 female) instructed to land softly and stiffly in different trials were collected in biplane fluoroscopy as they performed the landing from a height of 40 cm. Results Average and maximum relative anterior tibial translation (average, 2.8 ± 1.2 mm vs 3.0 ± 1.4 mm; maximum, 4.7 ± 1.6 mm vs 4.4 ± 0.8 mm), internal/external rotation (average, 3.7° ± 5.1° vs 2.7° ± 4.3°; maximum, 5.6° ± 5.5° vs 4.9° ± 4.7°), and varus/valgus (average, 0.2° ± 1.2° vs 0.2° ± 1.0°; maximum, 1.7° ± 1.2° vs 1.6° ± 0.9°) were all similar between soft and stiff landings, respectively. The peak vertical ground-reaction force was significantly larger for stiff landings than for soft landings (2.60 ± 1.32 body weight vs 1.63 ± 0.73; P < .001). The knee flexion angle total range of motion from the minimum angle at contact to the maximum angle at peak knee flexion was significantly greater for soft landings than for stiff (55.4° ± 8.8° vs 36.8° ± 11.1°; P < .01). Conclusion Stiff landings, as defined by significantly lower knee flexion angles and significantly greater peak ground-reaction forces, do not result in larger amounts of anterior tibial translation or knee rotation in either varus/valgus or internal/external rotation in healthy individuals. Clinical Relevance In healthy knees, the musculature and soft tissues of the knee are able to maintain translations and rotations within a small, safe range during controlled landing tasks of differing demand. The knee kinematics of this healthy population will serve as a comparison for injured knees in future studies. It should be stressed that because the authors did not compare how the loads were distributed over the soft tissues of the knee between the 2 landing styles, the larger ground-reaction forces and more extended knee position observed during stiff landings should still be considered dangerous to the anterior cruciate ligament and other structures of the lower extremities, particularly in competitive settings where movements are often unanticipated. PMID:21602566
Body size and lower limb posture during walking in humans
Hora, Martin; Soumar, Libor; Pontzer, Herman; Sládek, Vladimír
2017-01-01
We test whether locomotor posture is associated with body mass and lower limb length in humans and explore how body size and posture affect net joint moments during walking. We acquired gait data for 24 females and 25 males using a three-dimensional motion capture system and pressure-measuring insoles. We employed the general linear model and commonality analysis to assess the independent effect of body mass and lower limb length on flexion angles at the hip, knee, and ankle while controlling for sex and velocity. In addition, we used inverse dynamics to model the effect of size and posture on net joint moments. At early stance, body mass has a negative effect on knee flexion (p < 0.01), whereas lower limb length has a negative effect on hip flexion (p < 0.05). Body mass uniquely explains 15.8% of the variance in knee flexion, whereas lower limb length uniquely explains 5.4% of the variance in hip flexion. Both of the detected relationships between body size and posture are consistent with the moment moderating postural adjustments predicted by our model. At late stance, no significant relationship between body size and posture was detected. Humans of greater body size reduce the flexion of the hip and knee at early stance, which results in the moderation of net moments at these joints. PMID:28192522
Hart, Harvi F; Culvenor, Adam G; Collins, Natalie J; Ackland, David C; Cowan, Sallie M; Machotka, Zuzana; Crossley, Kay M
2016-05-01
Abnormal gait after anterior cruciate ligament reconstruction (ACLR) may contribute to development and/or progression of knee osteoarthritis. To conduct a systematic review and meta-analysis of knee kinematics and joint moments during walking after ACLR. We searched seven electronic databases and reference lists of relevant papers, for cross-sectional, human-based observational studies comparing knee joint kinematics and moments during level walking in individuals with ACLR, with the uninjured contralateral knee or healthy individuals as a control. Two independent reviewers appraised methodological quality (modified Downs and Black scale). Where possible, data were pooled by time post-ACLR (RevMan), otherwise narrative synthesis was undertaken. Thirty-four studies were included. Meta-analysis revealed significant sagittal plane deficits in ACLR knees. We found greater knee flexion angles (standardised mean difference: 1.06; 95% CI 0.39 to 1.74) and joint moments (1.61; 0.87 to 2.35) <6 months post-ACLR, compared to healthy controls. However, lower peak knee flexion angles were identified 1-3 years (-2.21; -3.16 to -1.26) and ≥3 years post-ACLR (-1.38, -2.14 to -0.62), and lower knee flexion moment 6-12 months post-ACLR (-0.76; -1.40 to -0.12). Pooled data provided strong evidence of no difference in peak knee adduction moment >3 years after ACLR (vs healthy controls) (0.09; -0.63 to 0.81). No transverse plane conclusions could be drawn. Sagittal plane biomechanics, rather than the knee adduction moment, appear to be more relevant post-ACLR. Better understanding of sagittal plane biomechanics is necessary for optimal post-operative recovery, and to potentially prevent early onset and progression of knee OA after ACLR. PROSPERO systematic review protocol registration number CRD4201400882 2. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Knee biomechanics during a jump-cut maneuver: Effects of gender & ACL surgery
Miranda, Daniel L.; Fadale, Paul D.; Hulstyn, Michael J.; Shalvoy, Robert M.; Machan, Jason T.; Fleming, Braden C.
2012-01-01
Purpose The purpose of this study was to compare kinetic and knee kinematic measurements from male and female ACL-intact (ACLINT) and ACL-reconstructed (ACLREC) subjects during a jump-cut maneuver using biplanar videoradiography. Methods Twenty subjects were recruited; 10 ACLINT (5 males, 5 females) and 10 ACLREC (4 males, 6 females; five years post surgery). Each subject performed a jump-cut maneuver by landing on a single leg and performing a 45° side-step cut. Ground reaction force was measured by a force plate and expressed relative to body weight. Six-degree-of-freedom knee kinematics were determined from a biplanar videoradiography system and an optical motion capture system. Results ACLINT female subjects landed with a larger peak vertical GRF (p<0.001) compared to ACLINT male subjects. ACLINT subjects landed with a larger peak vertical GRF (p≤0.036) compared to ACLREC subjects. Regardless of ACL reconstruction status, female subjects underwent less knee flexion angle excursion (p=0.002) and had an increased average rate of anterior tibial translation (0.05±0.01%/millisecond; p=0.037) after contact compared to male subjects. Furthermore, ACLREC subjects had a lower rate of anterior tibial translation compared to ACLINT subjects (0.05±0.01%/millisecond; p=0.035). Finally, no striking differences were observed in other knee motion parameters. Conclusion Women permit a smaller amount of knee flexion angle excursion during a jump-cut maneuver, resulting in a larger peak vertical GRF and increased rate of anterior tibial translation. Notably, ACLREC subjects also perform the jump cut maneuver with lower GRF than ACLINT subjects five years post surgery. This study proposes a causal sequence whereby increased landing stiffness (larger peak vertical GRF combined with less knee flexion angle excursion) leads to an increased rate of anterior tibial translation while performing a jump-cut maneuver. PMID:23190595
Muyor, José M; Alacid, Fernando; López-Miñarro, Pedro A
2011-09-01
The purpose of this study was to determine the influence of hamstring muscles extensibility in standing, maximal trunk flexion with knees extended and on the bicycle in lower handlebar-hands position of highly trained cyclists. Ninety-six cyclists were recruited for the study (mean ± SD, age: 30.36 ± 5.98 years). Sagittal spinal curvatures and pelvic tilt were measured in the standing position, maximal trunk flexion with knees extended (sit-and-reach test) and while sitting on a bicycle in lower handlebar-hand position using a Spinal Mouse system. Hamstring muscles extensibility was determined in both legs by passive straight leg raise test (PSLR). The sample was divided into three groups according to PSLR angle: (1) reduced extensibility (PSLR < 80º; n = 30), (2) moderate hamstring extensibility group (PSLR = 80º - 90º; n = 35), and (3) high hamstring extensibility (PSLR = > 90º; n = 31). ANOVA analysis showed significant differences among groups for thoracic (p < 0.001) and pelvic tilt (p < 0.001) angles in the sit-and-reach test. No differences were found between groups for standing and on the bicycle position. Post hoc analysis showed significant differences in all pairwise comparisons for thoracic angle (p < 0.01) and pelvic angle (p < 0.001) in the sit-and-reach test. No differences were found in lumbar angle in any posture. In conclusion, the hamstring muscles extensibility influence the thoracic and pelvic postures when maximal trunk flexion with knees extended is performed, but not when cyclists are seated on their bicycles.
Muyor, José M.; Alacid, Fernando; López-Miñarro, Pedro A.
2011-01-01
The purpose of this study was to determine the influence of hamstring muscles extensibility in standing, maximal trunk flexion with knees extended and on the bicycle in lower handlebar-hands position of highly trained cyclists. Ninety-six cyclists were recruited for the study (mean ± SD, age: 30.36 ± 5.98 years). Sagittal spinal curvatures and pelvic tilt were measured in the standing position, maximal trunk flexion with knees extended (sit-and-reach test) and while sitting on a bicycle in lower handlebar-hand position using a Spinal Mouse system. Hamstring muscles extensibility was determined in both legs by passive straight leg raise test (PSLR). The sample was divided into three groups according to PSLR angle: (1) reduced extensibility (PSLR < 80º; n = 30), (2) moderate hamstring extensibility group (PSLR = 80º – 90º; n = 35), and (3) high hamstring extensibility (PSLR = > 90º; n = 31). ANOVA analysis showed significant differences among groups for thoracic (p < 0.001) and pelvic tilt (p < 0.001) angles in the sit-and-reach test. No differences were found between groups for standing and on the bicycle position. Post hoc analysis showed significant differences in all pairwise comparisons for thoracic angle (p < 0.01) and pelvic angle (p < 0.001) in the sit-and-reach test. No differences were found in lumbar angle in any posture. In conclusion, the hamstring muscles extensibility influence the thoracic and pelvic postures when maximal trunk flexion with knees extended is performed, but not when cyclists are seated on their bicycles PMID:23486997
Hsu, Chao-Jung; George, Steven Z; Chmielewski, Terese L
2016-12-01
Clinicians use the single-leg hop test to assess readiness for return to sports after knee injury. Few studies have reported the results of single-leg hop testing after meniscectomy. Additionally, the contributions of impairments in quadriceps strength and psychosocial factors to single-leg hop performance are unknown. To compare single-leg hop performance (distance and landing mechanics) between limbs and to examine the association of single-leg hop performance with quadriceps strength and psychosocial factors in patients with meniscectomy. Descriptive laboratory study. A total of 22 subjects who underwent meniscectomy for traumatic meniscal tears received either standard rehabilitation alone or with additional quadriceps strengthening. Testing was conducted immediately postrehabilitation and at 1 year postsurgery. A single-leg hop test was performed bilaterally, and hop distance was used to create a hop symmetry index. Landing mechanics (peak knee flexion angle, knee extension moment, and peak vertical ground-reaction force) were analyzed with a motion-capture system and a force plate. An isokinetic dynamometer (60 deg/s) assessed knee extensor peak torque and rate of torque development (RTD 0-200ms and RTD 0-peak torque ). Questionnaires assessed fear of reinjury (Tampa Scale for Kinesiophobia [TSK-11]) and self-efficacy (Knee Activity Self-Efficacy [KASE]). Rehabilitation groups did not significantly differ in single-leg hop performance; therefore, groups were combined for further analyses. The mean hop symmetry index was 88.6% and 98.9% at postrehabilitation and 1 year postsurgery, respectively. Compared with the nonsurgical limb, the surgical limb showed decreased peak knee flexion angle at postrehabilitation and decreased knee extension moment at 1 year postsurgery. The hop symmetry index was positively associated with peak torque, RTD 0-200ms , and the KASE score at postrehabilitation. Moreover, at postrehabilitation, the peak knee flexion angle was positively associated with peak torque and RTD 0-200ms , and the knee extension moment was positively associated with RTD 0-200ms . At 1 year postsurgery, peak knee flexion angle and knee extension moment were both positively associated with peak torque, RTD 0-200ms , and RTD 0-peak torque . Although the hop symmetry index could be considered satisfactory for returning to sports, asymmetries in landing mechanics still exist in the first year postmeniscectomy. Greater quadriceps strength was associated with greater single-leg hop distance and better landing mechanics at both postrehabilitation and 1 year postsurgery. Knee activity self-efficacy was the only psychosocial factor associated with single-leg hop performance and isolated to a positive association with single-leg hop distance at postrehabilitation. Rate of development is not typically measured in the clinic but can be an additional quadriceps measure to monitor for single-leg hop performance. Quadriceps strength and psychosocial factors appear to have separate influence on single-leg hop performance after meniscectomy, which has implications for developing appropriate interventions for optimal single-leg hop performance.
Hsu, Chao-Jung; George, Steven Z.; Chmielewski, Terese L.
2016-01-01
Background: Clinicians use the single-leg hop test to assess readiness for return to sports after knee injury. Few studies have reported the results of single-leg hop testing after meniscectomy. Additionally, the contributions of impairments in quadriceps strength and psychosocial factors to single-leg hop performance are unknown. Purpose: To compare single-leg hop performance (distance and landing mechanics) between limbs and to examine the association of single-leg hop performance with quadriceps strength and psychosocial factors in patients with meniscectomy. Study Design: Descriptive laboratory study. Methods: A total of 22 subjects who underwent meniscectomy for traumatic meniscal tears received either standard rehabilitation alone or with additional quadriceps strengthening. Testing was conducted immediately postrehabilitation and at 1 year postsurgery. A single-leg hop test was performed bilaterally, and hop distance was used to create a hop symmetry index. Landing mechanics (peak knee flexion angle, knee extension moment, and peak vertical ground-reaction force) were analyzed with a motion-capture system and a force plate. An isokinetic dynamometer (60 deg/s) assessed knee extensor peak torque and rate of torque development (RTD0-200ms and RTD0–peak torque). Questionnaires assessed fear of reinjury (Tampa Scale for Kinesiophobia [TSK-11]) and self-efficacy (Knee Activity Self-Efficacy [KASE]). Results: Rehabilitation groups did not significantly differ in single-leg hop performance; therefore, groups were combined for further analyses. The mean hop symmetry index was 88.6% and 98.9% at postrehabilitation and 1 year postsurgery, respectively. Compared with the nonsurgical limb, the surgical limb showed decreased peak knee flexion angle at postrehabilitation and decreased knee extension moment at 1 year postsurgery. The hop symmetry index was positively associated with peak torque, RTD0-200ms, and the KASE score at postrehabilitation. Moreover, at postrehabilitation, the peak knee flexion angle was positively associated with peak torque and RTD0-200ms, and the knee extension moment was positively associated with RTD0-200ms. At 1 year postsurgery, peak knee flexion angle and knee extension moment were both positively associated with peak torque, RTD0-200ms, and RTD0–peak torque. Conclusion: Although the hop symmetry index could be considered satisfactory for returning to sports, asymmetries in landing mechanics still exist in the first year postmeniscectomy. Greater quadriceps strength was associated with greater single-leg hop distance and better landing mechanics at both postrehabilitation and 1 year postsurgery. Knee activity self-efficacy was the only psychosocial factor associated with single-leg hop performance and isolated to a positive association with single-leg hop distance at postrehabilitation. Clinical Relevance: Rate of development is not typically measured in the clinic but can be an additional quadriceps measure to monitor for single-leg hop performance. Quadriceps strength and psychosocial factors appear to have separate influence on single-leg hop performance after meniscectomy, which has implications for developing appropriate interventions for optimal single-leg hop performance. PMID:28210647
Conlisk, N.; Gray, H.; Pankaj, P.; Howie, C. R.
2012-01-01
Objectives Orthopaedic surgeons use stems in revision knee surgery to obtain stability when metaphyseal bone is missing. No consensus exists regarding stem size or method of fixation. This in vitro study investigated the influence of stem length and method of fixation on the pattern and level of relative motion at the bone–implant interface at a range of functional flexion angles. Methods A custom test rig using differential variable reluctance transducers (DVRTs) was developed to record all translational and rotational motions at the bone–implant interface. Composite femurs were used. These were secured to permit variation in flexion angle from 0° to 90°. Cyclic loads were applied through a tibial component based on three peaks corresponding to 0°, 10° and 20° flexion from a normal walking cycle. Three different femoral components were investigated in this study for cementless and cemented interface conditions. Results Relative motions were found to increase with flexion angle. Stemmed implants reduced relative motions in comparison to stemless implants for uncemented constructs. Relative motions for cemented implants were reduced to one-third of their equivalent uncemented constructs. Conclusions Stems are not necessary for cemented implants when the metaphyseal bone is intact. Short cemented femoral stems confer as much stability as long uncemented stems. PMID:23610659
von Eisenhart-Rothe, Ruediger; Lenze, Ulrich; Hinterwimmer, Stefan; Pohlig, Florian; Graichen, Heiko; Stein, Thomas; Welsch, Frederic; Burgkart, Rainer
2012-11-26
The posterior cruciate ligament (PCL) plays an important role in maintaining physiological kinematics and function of the knee joint. To date mainly in-vitro models or combined magnetic resonance and fluoroscopic systems have been used for quantifying the importance of the PCL. We hypothesized, that both tibiofemoral and patellofemoral kinematic patterns are changed in PCL-deficient knees, which is increased by isometric muscle flexion. Therefore the aim of this study was to simultaneously investigate tibiofemoral and patellofemoral 3D kinematics in patients suffering from PCL deficiency during different knee flexion angles and under neuromuscular activation. We enrolled 12 patients with isolated PCL-insufficiency as well as 20 healthy volunteers. Sagittal MR-images of the knee joint were acquired in different positions of the knee joint (0°, 30°, 90° flexion, with and without flexing isometric muscle activity) on a 0.2 Tesla open MR-scanner. After segmentation of the patella, femur and tibia local coordinate systems were established to define the spatial position of these structures in relation to each other. At full extension and 30° flexion no significant difference was observed in PCL-deficient knee joints neither for tibiofemoral nor for patellofemoral kinematics. At 90° flexion the femur of PCL-deficient patients was positioned significantly more anteriorly in relation to the tibia and both, the patellar tilt and the patellar shift to the lateral side, significantly increased compared to healthy knee joints. While no significant effect of isometric flexing muscle activity was observed in healthy individuals, in PCL-deficient knee joints an increased paradoxical anterior translation of the femur was observed at 90° flexion compared to the status of muscle relaxation. Significant changes in tibiofemoral and patellofemoral joint kinematics occur in patients with isolated PCL-insufficiency above 30 degrees of flexion compared to healthy volunteers. Since this could be one reasonable mechanism in the development of osteoarthritis (OA) our results might help to understand the long-term development of tibiofemoral and/or patellofemoral OA in PCL-insufficient knee joints.
Gao, Shu-Guang; Zhang, Can; Zhao, Rui-Bo; Liao, Zhan; Li, Yu-Sheng; Yu, Fang; Zeng, Chao; Luo, Wei; Li, Kang-Hua; Lei, Guang-Hua
2013-09-01
The relationship between medial meniscus tear and posterior cruciate ligament (PCL) injury has not been exactly explained. We studied to investigate the biomechanical effect of partial and complete PCL transection on different parts of medial meniscus at different flexion angles under static loading conditions. TWELVE FRESH HUMAN CADAVERIC KNEE SPECIMENS WERE DIVIDED INTO FOUR GROUPS: PCL intact (PCL-I), anterolateral bundle transection (ALB-T), posteromedial bundle transection (PMB-T) and PCL complete transection (PCL-T) group. Strain on the anterior horn, body part and posterior horn of medial meniscus were measured under different axial compressive tibial loads (200-800 N) at 0°, 30°, 60° and 90° knee flexion in each groups respectively. Compared with the PCL-I group, the PCL-T group had a higher strain on whole medial meniscus at 30°, 60° and 90° flexion in all loading conditions and at 0° flexion with 400, 600 and 800 N loads. In ALB-T group, strain on whole meniscus increased at 30°, 60° and 90° flexion under all loading conditions and at 0° flexion with 800 N only. PMB-T exihibited higher strain at 0° flexion with 400 N, 600 N and 800 N, while at 30° and 60° flexion with 800 N and at 90° flexion under all loading conditions. Partial PCL transection triggers strain concentration on medial meniscus and the effect is more pronounced with higher loading conditions at higher flexion angles.
Perez-Blanca, Ana; Espejo-Baena, Alejandro; Amat Trujillo, Daniel; Prado Nóvoa, María; Espejo-Reina, Alejandro; Quintero López, Clara; Ezquerro Juanco, Francisco
2016-04-01
To compare the effects of lateral meniscus posterior root avulsion left in situ, its repair, and meniscectomy on contact pressure distribution in both tibiofemoral compartments at different flexion angles. Eight cadaveric knees were tested under compressive 1000 N load for 4 lateral meniscus conditions (intact, posterior root avulsion, transosseous root repair, and total meniscectomy) at flexion angles 0°, 30°, 60°, and 90°. Contact area and pressure distribution were registered using K-scan pressure sensors inserted between menisci and tibial plateau. In the lateral compartment, root detachment decreased contact area (P = .017, 0° and 30°; P = .012, 60° and 90°) and increased mean (P = .012, all angles) and maximum (P = .025, 0° and 30°; P = .017, 60°; P = .012, 90°) pressures relative to intact condition. Repair restored all measured parameters close to intact at 0°, but effectiveness decreased with flexion angle, yielding no significant effect at 90°. Meniscectomy produced higher decreases than root avulsion in contact area (P = .012, 0° and 90°; P = .05, 30° and 60°) and increases in mean (P = .017, 0° and 30°; P = .018, 90°) and maximum pressure (P = .012, 0°; P = .036, 30°). In the medial compartment, lesion changed the contact area at high flexion angles only, while meniscectomy induced greater changes at all angles. Lateral meniscus posterior root avulsion generates significant alterations in contact area and pressures at lateral knee compartment for flexion angles between full extension and 90°. Meniscectomy causes greater disorders than the avulsion left in situ. Transosseous repair with a single suture restores these alterations to conditions close to intact at 0° and 30° but not at 60° and 90°. Altered contact mechanics after lateral meniscus posterior root avulsion might have degenerative consequences. Transosseous repair with one suture should be revised to effectively restore contact mechanics at high flexion angles. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Luna-Pizarro, Daniel; Amato, Dante; Arellano, Francisco; Hernández, Armando; López-Rojas, Pablo
2006-09-01
To compare the percutaneous patellar osteosynthesis system (PPOS) technique with open surgery for patella fractures. Randomized controlled trial. Referral orthopedic and trauma center. Fifty-three patients with displaced patellar fractures. Stabilization and fixation of patellar fractures with PPOS or open surgery. Knee-flexion and -extension angles, pain, surgical time, and assessment of knee function based on the Knee Society Clinical Rating Scale (KSCRS). Comparison of PPOS and open-surgery groups at 4 weeks showed the following: pain, 3.7 +/- 1.6 versus 6.2 +/- 1.4 arbitrary units, P < 0.001; flexion angle, 46 +/- 20.7 versus 12.7 +/- 6.0 degrees, P < 0.001; extension angle, -2.5 versus -3.8 degrees, P < 0.001. At 8 weeks, the following was demonstrated: pain, 1.3 +/- 1.6 versus 4.1 +/- 2.1 arbitrary units, P < 0.001; flexion angle, 87 +/- 17.3 versus 34 +/- 26 degrees, P < 0.001; extension angle, 0 versus -3 degrees, P < 0.001. Surgical time was 35.3 +/- 7.8 versus 66.2 +/- 14.1 minutes, P < 0.001. KSCRS assessment was 84 +/- 4 versus 70 +/- 8, P < 0.001 at 8 weeks; 85 +/- 2 versus 73 +/- 8, P < 0.001 at 12 months; and 85 +/- 1 versus 82 +/- 7, P = 0.246 at 24 months. Frequency of total complications (infections, fragment displacement, and wire-related pain) was significantly lower in the PPOS than in the open-surgery group (P < 0.02). PPOS for patella fractures was associated with shorter surgical time, less pain, better mobility angles, higher functional score up to 2 years, and a lower incidence of complications than open surgery.
Validation of a novel smartphone accelerometer-based knee goniometer.
Ockendon, Matthew; Gilbert, Robin E
2012-09-01
Loss of full knee extension following anterior cruciate ligament surgery has been shown to impair knee function. However, there can be significant difficulties in accurately and reproducibly measuring a fixed flexion of the knee. We studied the interobserver and the intraobserver reliabilities of a novel, smartphone accelerometer-based, knee goniometer and compared it with a long-armed conventional goniometer for the assessment of fixed flexion knee deformity. Five healthy male volunteers (age range 30 to 40 years) were studied. Measurements of knee flexion angle were made with a telescopic-armed goniometer (Lafayette Instrument, Lafayette, IN) and compared with measurements using the smartphone (iPhone 3GS, Apple Inc., Cupertino, CA) knee goniometer using a novel trigonometric technique based on tibial inclination. Bland-Altman analysis of validity and reliability including statistical analysis of correlation by Pearson's method was undertaken. The iPhone goniometer had an interobserver correlation (r) of 0.994 compared with 0.952 for the Lafayette. The intraobserver correlation was r = 0.982 for the iPhone (compared with 0.927). The datasets from the two instruments correlate closely (r = 0.947) are proportional and have mean difference of only -0.4 degrees (SD 3.86 degrees). The Lafayette goniometer had an intraobserver reliability +/- 9.6 degrees. The interobserver reliability was +/- 8.4 degrees. By comparison the iPhone had an interobserver reliability +/- 2.7 degrees and an intraobserver reliability +/- 4.6 degrees. We found the iPhone goniometer to be a reliable tool for the measurement of subtle knee flexion in the clinic setting.
EMG and tibial shock upon the first attempt at barefoot running.
Olin, Evan D; Gutierrez, Gregory M
2013-04-01
As a potential means to decrease their risk of injury, many runners are transitioning into barefoot running. Habitually shod runners tend to heel-strike (SHS), landing on their heel first, while barefoot runners tend to mid-foot or toe-strike (BTS), landing flat-footed or on the ball of their foot before bringing down the rest of the foot including the heel. This study compared muscle activity, tibial shock, and knee flexion angle in subjects between shod and barefoot conditions. Eighteen habitually SHS recreational runners ran for 3 separate 7-minute trials, including SHS, barefoot heel-strike (BHS), and BTS conditions. EMG, tibial shock, and knee flexion angle were monitored using bipolar surface electrodes, an accelerometer, and an electrogoniometer, respectively. A one-way MANOVA for repeated measures was conducted and several significant changes were noted between SHS and BTS, including significant increases in average EMG of the medial gastrocnemius (p=.05), average and peak tibial shock (p<.01), and the minimum knee flexion angle (p<.01). Based on our data, the initial change in mechanics may have detrimental effects on the runner. While it has been argued that BTS running may ultimately be less injurious, these data indicate that habitually SHS runners who choose to transition into a BTS technique must undertake the process cautiously. Copyright © 2012 Elsevier B.V. All rights reserved.
Wang, Lianxin; Lin, Lin; Feng, Yong; Fernandes, Tiago Lazzaretti; Asnis, Peter; Hosseini, Ali; Li, Guoan
2015-12-01
Clinical outcome studies showed a high incidence of knee osteoarthritis after anterior cruciate ligament reconstruction. Abnormal joint kinematics and loading conditions were assumed as risking factors. However, little is known on cartilage contact forces after the surgery. A validated computational model was used to simulate anatomic and transtibial single-bundle anterior cruciate ligament reconstructions. Two graft fixation angles (0° and 30°) were simulated for each reconstruction. Biomechanics of the knee was investigated in intact, anterior cruciate ligament deficient and reconstructed conditions when the knee was subjected to 134 N anterior load and 400 N quadriceps load at 0°, 30°, 60° and 90° of flexion. The tibial translation and rotation, graft forces, medial and lateral contact forces were calculated. When the graft was fixed at 0°, the anatomic reconstruction resulted in slightly larger lateral contact force at 0° compared to the intact knee while the transtibial technique led to higher contact force at both 0° and 30° under the muscle load. When graft was fixed at 30°, the anatomic reconstruction overstrained the knee at 0° with larger contact forces, while the transtibial technique resulted in slightly larger contact forces at 30°. This study suggests that neither the anatomic nor the transtibial reconstruction can consistently restore normal knee biomechanics at different flexion angles. The anatomic reconstruction may better restore anteroposterior stability and contact force with the graft fixed at 0°. The transtibial technique may better restore knee anteroposterior stability and articular contact force with the graft fixed at 30° of flexion. Copyright © 2015 Elsevier Ltd. All rights reserved.
Murakami, Koji; Hamai, Satoshi; Okazaki, Ken; Ikebe, Satoru; Shimoto, Takeshi; Hara, Daisuke; Mizu-uchi, Hideki; Higaki, Hidehiko; Iwamoto, Yukihide
2016-03-01
Participation in specific activities requires complex ranges of knee movements and activity-dependent kinematics. The purpose of this study was to investigate dynamic knee kinematics during squat and golf swing using image-matching techniques. Five healthy males performed squats and golf swings under periodic X-ray images at 10 frames per second. We analyzed the in vivo three-dimensional kinematic parameters of subjects' knees, namely the tibiofemoral flexion angle, anteroposterior (AP) translation, and internal-external rotation, using serial X-ray images and computed tomography-derived, digitally reconstructed radiographs. During squat from 0° to 140° of flexion, the femur moved about 25 mm posteriorly and rotated 19° externally relative to the tibia. Screw-home movement near extension, bicondylar rollback between 20° and 120° of flexion, and medial pivot motion at further flexion were observed. During golf swing, the leading and trailing knees (the left and right knees respectively in the right-handed golfer) showed approximately five millimeters and four millimeters of AP translation with 18° and 26° of axial rotation, respectively. A central pivot motion from set-up to top of the backswing, lateral pivot motion from top to ball impact, and medial pivot motion from impact to the end of follow-through were observed. The medial pivot motion was not always recognized during both activities, but a large range of axial rotation with bilateral condylar AP translations occurs during golf swing. This finding has important implications regarding the amount of acceptable AP translation and axial rotation at low flexion in replaced knees. IV. Copyright © 2015 Elsevier B.V. All rights reserved.
Bellmann, Malte; Schmalz, Thomas; Ludwigs, Eva; Blumentritt, Siegmar
2012-03-01
To investigate the immediate biomechanical effects after transition to a new microprocessor-controlled prosthetic knee joint. Intervention cross-over study with repeated measures. Only prosthetic knee joints were changed. Motion analysis laboratory. Men (N=11; mean age ± SD, 36.7±10.2y; Medicare functional classification level, 3-4) with unilateral transfemoral amputation. Two microprocessor-controlled prosthetic knee joints: C-Leg and a new prosthetic knee joint, Genium. Static prosthetic alignment, time-distance parameters, kinematic and kinetic parameters, and center of pressure. After a half-day training and an additional half-day accommodation, improved biomechanical outcomes were demonstrated by the Genium: lower ground reaction forces at weight acceptance during level walking at various velocities, increased swing phase flexion angles during walking on a ramp, and level walking with small steps. Maximum knee flexion angle during swing phase at various velocities was nearly equal for Genium. Step-over-step stair ascent with the Genium knee was more physiologic as demonstrated by a more equal load distribution between the prosthetic and contralateral sides and a more natural gait pattern. When descending stairs and ramps, knee flexion moments with the Genium tended to increase. During quiet stance on a decline, subjects using Genium accepted higher loading of the prosthetic side knee joint, thus reducing same side hip joint loading as well as postural sway. In comparision to the C-Leg, the Genium demonstrated immediate biomechanical advantages during various daily ambulatory activities, which may lead to an increase in range and diversity of activity of people with above-knee amputations. Results showed that use of the Genium facilitated more natural gait biomechanics and load distribution throughout the affected and sound musculoskeletal structure. This was observed during quiet stance on a decline, walking on level ground, and walking up and down ramps and stairs. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Effects of muscle activation on shear between human soleus and gastrocnemius muscles.
Finni, T; Cronin, N J; Mayfield, D; Lichtwark, G A; Cresswell, A G
2017-01-01
Lateral connections between muscles provide pathways for myofascial force transmission. To elucidate whether these pathways have functional roles in vivo, we examined whether activation could alter the shear between the soleus (SOL) and lateral gastrocnemius (LG) muscles. We hypothesized that selective activation of LG would decrease the stretch-induced shear between LG and SOL. Eleven volunteers underwent a series of knee joint manipulations where plantar flexion force, LG, and SOL muscle fascicle lengths and relative displacement of aponeuroses between the muscles were obtained. Data during a passive full range of motion were recorded, followed by 20° knee extension stretches in both passive conditions and with selective electrical stimulation of LG. During active stretch, plantar flexion force was 22% greater (P < 0.05) and relative displacement of aponeuroses was smaller than during passive stretch (P < 0.05). Soleus fascicle length changes did not differ between passive and active stretches but LG fascicles stretched less in the active than passive condition when the stretch began at angles of 70° and 90° of knee flexion (P < 0.05). The activity-induced decrease in the relative displacement of SOL and LG suggests stronger (stiffer) connectivity between the two muscles, at least at flexed knee joint angles, which may serve to facilitate myofascial force transmission. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Hewett, T E; Lynch, T R; Myer, G D; Ford, K R; Gwin, R C; Heidt, R S
2014-01-01
Objective A multifactorial combination of predictors may increase anterior cruciate ligament (ACL) injury risk in athletes. The objective of this twin study was to examine these risk factors to identify commonalities in risk factors that predisposed female fraternal twins to ACL injury. Methods Female twins in high-risk sports were prospectively measured prior to an injury for neuromuscular control using three-dimensional motion analysis during landing, hamstrings and quadriceps muscular strength on a dynamometer and joint laxity using a modified Beighton–Horan index and a Compu-KT arthrometer. Intraoperative measures of femoral intercondylar notch width were recorded during ACL reconstruction. Results Abduction angles were increased at one knee in both of the twin sister athletes relative to uninjured controls at initial contact and at maximum displacement during landing. The twin female athletes that went on to ACL injury also demonstrated decreased peak knee flexion motion at both knees than uninjured females during landing. The twin athletes also had increased joint laxity and decreased hamstrings to quadriceps (H/Q) torque ratios compared to controls. Femoral intercondylar notch widths were also below the control mean in the twin siblings. Conclusions Prescreened mature female twins that subsequently experienced ACL injury demonstrated multiple potential risk factors including: increased knee abduction angles, decreased knee flexion angles, increased general joint laxity, decreased H/Q ratios and femoral intercondylar notch width. PMID:19158132
Petit, Philippe; Trosseille, Xavier; Dufaure, Nicolas; Dubois, Denis; Potier, Pascal; Vallancien, Guy
2014-11-01
In the ECE 127 Regulation on pedestrian leg protection, as well as in the Euro NCAP test protocol, a legform impactor hits the vehicle at the speed of 40 kph. In these tests, the knee is fully extended and the leg is not coupled to the upper body. However, the typical configuration of a pedestrian impact differs since the knee is flexed during most of the gait cycle and the hip joint applies an unknown force to the femur. This study aimed at investigating the influence of the inertia of the upper body (modelled using an upper body mass fixed at the proximal end of the femur) and the initial knee flexion angle on the lower limb injury outcome. In total, 18 tests were conducted on 18 legs from 9 Post Mortem Human Subjects (PMHS). The principle of these tests was to impact the leg at 40 kph using a sled equipped with 3 crushing steel tubes, the stiffness of which were representative of the front face of a European sedan (bonnet leading edge, bumper and spoiler). The mass of the equipped sled was 74.5 kg. The test matrix was designed to perform 4 tests in 4 configurations combining two upper body masses (either 0 or 3 kg) and two knee angles (0 or 20 degrees) at 40 kph (11 m/s) plus 2 tests at 9 m/s. Autopsies were performed on the lower limbs and an injury assessment was established. The findings of this study were first that the increase of the upper body mass resulted in more severe injuries, second that an initial flexion of the knee, corresponding to its natural position during the gait cycle, decreased the severity of the injuries, and third that based on the injury outcome, a test conducted with no upper body mass and the knee fully extended was as severe as a test conducted with a 3 kg upper body mass and an initial knee flexion of 20°.
Oh, Won Seok; Lee, Yong Seuk; Kim, Byung Kak; Sim, Jae Ang; Lee, Beom Koo
2016-06-01
To analyze the contact mechanics of the femoral component and polyethylene of the Low Contact Stress rotating platform (LCS-RP) in nonweight bearing and weight bearing conditions using full flexion lateral radiographs. From May 2009 to December 2013, 58 knees in 41 patients diagnosed with osteoarthritis and treated with total knee arthroplasty (TKA) were included in this study. TKA was performed using an LCS-RP knee prosthesis. Full flexion lateral radiographs in both weight bearing and nonweight bearing condition were taken at least one month postoperatively (average, 28.8 months). Translation of femoral component was determined by the contact point between the femoral component and polyethylene. Maximum flexion was measured as the angle between the lines drawn at the midpoint of the femur and tibia. Posterior shift of the contact point in LCS-RP TKA was observed under weight bearing condition, which resulted in deeper flexion compared to LCS-RP TKA under nonweight bearing condition. In the LCS-RP TKA, the contact point between the femoral component and polyethylene moved posteriorly under weight bearing condition, and the joint was more congruent and maximum flexion increased with weight bearing.
Jenny, J-Y; Lefèbvre, Y; Vernizeau, M; Lavaste, F; Skalli, W
2002-12-01
In vitro experiments are particularly useful for studying kinematic changes from the normal knee to experimental conditions simulating different disease states. We developed an experimental protocol allowing a kinematic analysis of the femorotibial and femoropatellar joints in the healthy knee and after implantation of a knee prosthesis, according to the central pivot during simulated active loaded movement from the standing to sitting position. An experimental device was designed to apply force to the femur of a cadaveric specimen including the femur, the patella and the tibia. The tibia was angled in the sagittal plane and the femur was free to move in space in response to the geometric movement of the knee joint, the capsuloligamentary structures, the quadriceps tendon and gravity. Variation in the length of the quadriceps tendon controlled the flexion-extension movement. The experimental setup included computer-controlled activation allowing continuous coordinated movement of the femur relative to the tibia and of the tibia relative to the ground. Standard activations simulated movement from the standing to the sitting position. Five pairs of fresh-frozen cadaver specimens including the entire femur, patella, tibia and fibula, the capsuloligamentary and intra-articular structures of the knee, the superior and inferior tibiofibular ligaments and the quadriceps tendon were studied. The quadriceps tendon was connected to the computer-guided activation device. Reflectors were fixed onto the anterior aspect of the femur, the superior tibial epiphysis and the center of the patella. Anatomic landmarks on the femur, the tibia, and the patella were identified to determine the plane of movement of each bone in the three rotation axes and the three translation directions. Three infrared cameras recorded movements of the reflectors fixed on the bony segments and, by mathematical transformation, the movement of the corresponding bony segment, displayed in time-course curves. The patella moved in continuous fashion over the femur, directly following the angle of knee flexion with a ratio of about 60%, which was constant for all knees studied and for all configurations. The patella of healthy knees and knees implanted with a unicompartmental prosthesis exhibited medial rotation during the first 30 degrees of flexion, with a movement of about of 10 degrees, then a lateral rotation of about 10 degrees to 20 degrees when the flexion reached 90 degrees; implantation of a total knee prosthesis led to a medial rotation which was continuous from 5 degrees to 15 degrees. There was a trend towards continuous abduction of about 10 degrees. The patella exhibited a continuous anterior translation of 10 to 20 mm from the tibia with increasing knee flexion, in both normal and prosthetic knees (unicompartmental prosthesis); knees implanted with a total knee prosthesis exhibited 5 to 10 mm anterior translation from 0 degrees to 50 degrees flexion, then an equivalent posterior translation for 50 degrees to 90 degrees flexion. The patella made a continuous 5 to 10 mm medial translation movement over the tibia in both normal and prosthetic (unicompartmental) knees; knees implanted with a total knee prosthesis exhibited 0 to 5 mm lateral translation starting after 50 degrees flexion. The patella also exhibited a continuous distal translation over the tibia of about 20 to 30 mm, for all configurations. The experimental set up enables a comparison of the kinetics of a normal knee with the kinetics observed after implantation of a prosthesis on the same knee. Implantation of a unicompartmental medial prosthesis, leaving the posterior cruciate ligament intact and irrespective of the status of the anterior cruciate ligament, did not, in these experimental conditions, exhibit any significant difference in the femorotibial or femoropatellar kinetics compared with the same normal knee. Implantation of a total knee prosthesis had a significant effect on the femoropatellar kinematics, compared with the same knee before implantation. The main anomalies were related to the medial-lateral rotation of the patella which exhibited an abnormal lateral rotation, possibly favorable for subluxation; these changes were directly related to femorotibial rotation after implantation of the total prosthesis and appeared to be related to the symmetry of the femoral condyles of the prosthesis model studied, perturbing the normal automatic rotation of the knee. There is thus a strong relationship between femorotibial and femoropatellar kinetics in the total knee prosthesis.
Acute Effects of Hamstring Stretching on Sagittal Spinal Curvatures and Pelvic Tilt
López-Miñarro, Pedro A.; Muyor, José M.; Belmonte, Felipe; Alacid, Fernando
2012-01-01
The aim of this study was to determine acute effects of hamstring stretching in thoracic and lumbar spinal curvatures and pelvic tilt. Fifty-five adults (29.24 ± 7.41 years) were recruited for this study. Subjects performed a hamstring stretching protocol consisting of four exercises. The session consisted of 3 sets of each exercise and subjects held the position for 20 seconds with a 30-second rest period between sets and exercises. Thoracic and lumbar spinal angles and pelvic tilt were measured with a SpinalMouse in relaxed standing, sit-and-reach test and Macrae & Wright position. Hamstring extensibility was determined by active straight leg raise test and sit-and-reach score. All measures were performed before and immediately after the hamstring stretching protocol. Active straight leg raise angle and sitand-reach score significantly improved immediately after the stretching protocol (p<0.001). Greater anterior pelvic tilt (p<0.001) and lumbar flexion (p<0.05) and a smaller thoracic kyphosis in the sit-and-reach (p<0.001) were found after the stretching protocol. However, stretching produced no significant change on spinal curvatures or pelvic tilt in standing and maximal trunk flexion with knees flexed. In conclusion, static stretching of the hamstring is associated to an immediate change in the sagittal spinal curvatures and pelvic position when performing trunk flexion with knees extended, so that allowing for greater lumbar flexion and anterior pelvic tilt and lower thoracic kyphosis. Hamstring stretching is recommended prior to sport activities involving trunk flexion with the knees straight. PMID:23486214
Knee Kinematics is Altered Post-Fatigue While Performing a Crossover Task
Cortes, Nelson; Greska, Eric; Ambegaonkar, Jatin P.; Kollock, Roger O.; Caswell, Shane V.; Onate, James A.
2013-01-01
Purpose To examine the effect of a sequential fatigue protocol on lower extremity biomechanics during a crossover cutting task in female soccer players. Methods Eighteen female collegiate soccer players alternated between a fatigue protocol and two consecutive unanticipated crossover trials until fatigue was reached. Lower extremity biomechanics were evaluated during the crossover using a 3D motion capture system and two force plates. Repeated measures ANOVAs analyzed differences between three sequential stages of fatigue (pre, 50%, 100%) for each dependent variable (α=0.05). Results Knee flexion angles at initial contact (IC) for pre- (−32±9°) and 50% (−29±11°) were significantly higher than at 100% fatigue (−22±9°) (p<0.001 and p=0.015, respectively). Knee adduction angles at IC for pre- (9±5°) and 50% (8±4°) were significantly higher (p=0.006 and p=0.049, respectively) than at 100% fatigue (6±4°). Conclusions Fatigue altered sagittal and frontal knee kinematics after 50% fatigue whereupon participants had diminished knee control at initial contact. Interventions should attempt to reduce the negative effects of fatigue on lower extremity biomechanics by promotion appropriate frontal plane alignment, and increased knee flexion during fatigue status. PMID:24045915
Pinsornsak, Piya; Harnroongroj, Thos
2016-11-01
The specialized instrument system used in minimally invasive surgery (MIS) has been developed for reducing soft tissue trauma in total knee arthroplasty (TKA). Compared with front-cutting MIS instruments, side-cutting quadriceps sparing MIS instruments have the advantage of creating a smaller incision and causing fewer traumas to the quadriceps tendon. However, the accuracy of side-cutting instruments concerns surgeons in prosthesis malalignment. To compare the accuracy of side-cutting quadriceps sparing instruments versus front-cutting instruments in MIS-TKA. In this prospective randomized controlled study, we compared the accuracy of side-cutting quadriceps sparing instruments versus the front-cutting instruments used in MIS-TKA. Sixty knees were included in the study, with 30 knees in each group. All the operations were performed by single surgeon. Coronal alignment (tibiofemoral angle, lateral distal femoral angle, and medial proximal tibial angle), and sagittal alignment (femoral component flexion and tibial posterior slope) were measured and compared. Tibiofemoral angle, lateral distal femoral angle, and medial proximal tibial angle, all of which are considered in the assessment of acceptable coronal radiographic alignment, were not different between groups (p = 0.353, 0.500, and 0.177, respectively). However, side-cutting quadriceps sparing instruments produced less acceptable sagittal radiographic alignment, femoral component flexion (63% vs. 93%, p = 0.005), and tibial posterior slope (73% vs. 93%, p = 0.04). Side-cutting quadriceps sparing MIS-TKA instruments had similar accuracy to front-cutting MIS-TKA instruments for coronal alignment but is less accurate for sagittal alignment.
Morimoto, Yusuke; Ferretti, Mario; Ekdahl, Max; Smolinski, Patrick; Fu, Freddie H
2009-01-01
The purpose of this study was to compare the tibiofemoral contact area and pressure after single-bundle (SB) and double-bundle (DB) anterior cruciate ligament (ACL) reconstruction by use of 2 femoral and 2 tibial tunnels in intact cadaveric knees. Tibiofemoral contact area and mean and maximum pressures were measured by pressure-sensitive film (Fujifilm, Valhalla, NY) inserted between the tibia and femur. The knee was subjected to a 1,000-N axial load by use of a uniaxial testing machine at 0 degrees , 15 degrees , 30 degrees , and 45 degrees of flexion. Three conditions were evaluated: (1) intact ACL, (2) SB ACL reconstruction (n = 10 knees), and (3) DB ACL reconstruction (n = 9 knees). When compared with the intact knee, DB ACL reconstruction showed no significant difference in tibiofemoral contact area and mean and maximum pressures. SB ACL reconstruction had a significantly smaller contact area on the lateral and medial tibiofemoral joints at 30 degrees and 15 degrees of flexion. SB ACL reconstruction also had significantly higher mean pressures at 15 degrees of flexion on the medial tibiofemoral joint and at 0 degrees and 15 degrees of flexion on the lateral tibiofemoral joint, as well as significantly higher maximum pressures at 15 degrees of flexion on the lateral tibiofemoral joint. SB ACL reconstruction resulted in a significantly smaller tibiofemoral contact area and higher pressures. DB ACL more closely restores the normal contact area and pressure mainly at low flexion angles. Our findings suggest that the changes in the contact area and pressures after SB ACL reconstruction may be one of the causes of osteoarthritis on long-term follow-up. DB ACL reconstruction may reduce the incidence of osteoarthritis by closely restoring contact area and pressure.
Hino, Kazunori; Kutsuna, Tatsuhiko; Watamori, Kunihiko; Kiyomatsu, Hiroshi; Ishimaru, Yasumitsu; Takeba, Jun; Watanabe, Seiji; Shiraishi, Yoshitaka; Miura, Hiromasa
2017-10-01
Midflexion stability can potentially improve the outcome of total knee arthroplasty (TKA). The purpose of this study was to evaluate the correlation between varus-valgus stability at 0° of extension and 90° of flexion and that at the midflexion range in posterior-stabilized (PS)-TKA. Forty-three knees that underwent PS-TKA were evaluated. Manual mild passive varus-valgus stress was applied to the knees, and the postoperative maximum varus-valgus stability was measured every 10° throughout range of motion, using a navigation system. Correlations between the stability at 0°, 90° of flexion, and that at each midflexion angle were evaluated using Spearman's correlation coefficients. The stability of 0° modestly correlated with that of 10°-20°, but it did not significantly correlate with that of 30°-80°. However, the stability of 90° strongly correlated with that of 60°-80°, modestly correlated with that of 40°-50°, weakly correlated with that of 20°-30°, and did not correlate with that of 10°. The present study confirmed the importance of acquiring stability at 90° flexion to achieve midflexion stability in PS-TKA. However, initial flexion stability did not strongly correlate with the stability at either 0° or 90°. Our findings can provide useful information for understanding varus-valgus stability throughout the range of motion in PS-TKA. Attention to soft tissue balancing is necessary to stabilize a knee at the initial flexion range in PS-TKA.
An Intelligent Remote Monitoring System for Total Knee Arthroplasty Patients.
Msayib, Yunus; Gaydecki, Patrick; Callaghan, Michael; Dale, Nicola; Ismail, Sheheera
2017-06-01
For the first six weeks following total knee arthroplasty (TKA), a patient will attend an outpatient clinic typically seen twice weekly. Here, an exercise regime is performed and improvement assessed using a hand held goniometer that measures the maximum angle of knee flexion, an important metric of progress. Additionally a series of daily exercises is performed at home, recorded in a diary. This protocol has problems. Patients must attend the hospital with assistance since they are not permitted to drive for six weeks following the procedure; appointments are sometimes missed; there are occasionally not enough physiotherapy appointment available; furthermore, it is difficult to be sure that patients are compliant with their exercises at home. The economic and social costs are therefore significant both to the patient and the health service. We describe here an automatic system that performs the monitoring of knee flexion within a domestic environment rather than in a hospital setting. It comprises a master and slave sensor unit that attach using Velcro straps to the thigh and shin above and below the operation wound. The patient performs the prescribed knee exercises whilst wearing the device, during which time it measures and records the angles of knee flexion. The device utilises the Global System for Mobile Communications (GSM) infrastructure to transmit data through the Internet to a secure hospital-based server using an on-board GSM modem. The clinician is then able to view and interpret the information from any computer with internet access and the software. The system does not require the patient to possess a mobile telephone, a computer, or have internet access; the necessary communications technology is completely integrated into the device.
Simeone, F Joseph; Huang, Ambrose J; Chang, Connie Y; Smith, Maximilian; Gill, Thomas J; Bredella, Miriam A; Torriani, Martin
2015-04-01
To describe MRI features of an entity consisting of medial knee pain and edema between the posteromedial femoral condyle (PMFC), sartorius and/or gracilis tendons and determine whether reduced tendon-bone distances may account for these findings. We retrospectively identified MRI cases of edema between the PMFC, sartorius and/or gracilis tendons (25 subjects, 26 knees). Two musculoskeletal radiologists independently graded edema and measured the sartorius- and gracilis-PMFC distances and knee flexion angle. Age- and gender-matched subjects with normal knee MRIs (27 subjects, 27 knees) served as controls for measurements. Statistical analyses compared abnormal to control subjects. Sartorius-PMFC and gracilis-PMFC spaces were narrower in abnormal compared to control subjects (1.6 ± 1.0 vs. 2.1 ± 1.2 mm, P = 0.04; 2.3 ± 2.0 vs. 4.6 ± 3.0 mm, P = 0.002, respectively). The knee flexion angle was similar between groups (P > 0.05). In subjects with clinical information, medial knee pain was the main complaint in 58 % (15/26) of abnormal subjects, with 42 % (11/26) having clinical suspicion of medial meniscal tear. Edema between the PMFC, sartorius and/or gracilis was mild in 54 % (14/26), moderate in 35 % (9/26) and severe in 12 % (3/26), and it was most frequent deep to both the sartorius and gracilis (50 %, 13/26). Edema between the PMFC, sartorius and/or gracilis tendons identified on knee MRI may be associated with medial knee pain and may represent a friction syndrome.
Ishii, Yoshinori; Noguchi, Hideo; Sato, Junko; Sakurai, Tetsuya; Toyabe, Shin-Ichi
2017-11-01
It is still controversial whether anteroposterior (AP) translation magnitude after total knee arthroplasty (TKA) affects clinical outcomes, particularly range of motion (ROM). This study examined the following two questions: (1) are AP translations at the mid- and long-term follow-up different for knees within the same patient treated with posterior cruciate ligament-retaining (PCLR) versus posterior cruciate ligament-substituting (PCLS) mobile-bearing TKA prosthesis designs? (2) Is the ROM at the mid- and long-term follow-up for knees treated with PCLR and PCLS designs correlated with the AP translation? Thirty-seven patients undergoing sequential bilateral TKA for osteoarthritis were prospectively enrolled. Patients received a PCLR implant in one knee and a PCLS implant in the other and were followed-up for an average 9.8 ± 3.2 years. The AP translations at 30° and 75° of knee flexion and the ROM of both knees were assessed. The implant design (p < 0.001), but not flexion angle (n.s.), had a significant effect on AP translation. AP translation values were larger in PCLR knees than in PCLS knees at both flexion angles (p < 0.0001). The ROM at the final follow-up in the two implant designs was similar (both 115°, n.s.). There was a weak correlation between ROM and AP translation at 30° in the PCLR knees (r = 0.397, p = 0.015), but no correlation at 75° or in the PCLS knees. Differently constrained prosthesis designs resulted in significantly different AP translational values within the same patient. This indicates that achieving good clinical outcomes and ROM after TKA may not be strongly influenced by the specifics of each patient's anatomical characteristics, but instead by knee constrainment. Clinically, this means that surgeons should familiarize themselves with the AP translation of the implant being used, as this may be the most important factor for optimizing outcomes after mobile-bearing TKA. Level of evidence II, prospective, comparative study.
The influence of the test setup on knee joint kinematics - A meta-analysis of tibial rotation.
Hacker, Steffen P; Ignatius, Anita; Dürselen, Lutz
2016-09-06
The human knee is one of the most investigated joints in the human body. Various test setups exist to measure and analyse knee kinematics in vitro which differ in a wide range of parameters. The purpose of this article is to find an answer to the question if the test setup influences the kinematic outcome of studies and to what extend the results can be compared. To answer this question, we compared the tibial rotation as a function of flexion angle presented in 19 published studies. Raw data was extracted via image segmentation from the graphs depicted in these publications and the differences between the publications was analysed. Additionally, all test setups were compared regarding four aspects: method for angle calculation, system for data acquisition, loading condition and testing rig design. The resulting correlation matrix shows the influence of the test setup on the study outcome. Our results indicate that each study needs to collect its own reference data. Finally, we provide a mean internal rotation as a function of flexion angle based on more than 140 specimens tested in 14 different studies. Copyright © 2016 Elsevier Ltd. All rights reserved.
Bracing of the Reconstructed and Osteoarthritic Knee during High Dynamic Load Tasks.
Hart, Harvi F; Crossley, Kay M; Collins, Natalie J; Ackland, David C
2017-06-01
Lateral compartment osteoarthritis accompanied by abnormal knee biomechanics is frequently reported in individuals with knee osteoarthritis after anterior cruciate ligament reconstruction (ACLR). The aim of this study was to evaluate changes in knee biomechanics produced by an adjusted and unadjusted varus knee brace during high dynamic loading activities in individuals with lateral knee osteoarthritis after ACLR and valgus malalignment. Nineteen participants who had undergone ACLR 5 to 20 yr previously and had symptomatic and radiographic lateral knee osteoarthritis with valgus malalignment were assessed. Quantitative motion analysis experiments were conducted during hopping, stair ascent, and descent under three test conditions: (i) no brace, (ii) unadjusted brace with sagittal plane support and neutral frontal plane alignment, and (iii) adjusted brace with sagittal plane support and varus realignment (valgus to neutral). Sagittal, frontal, and transverse plane knee kinematics, external joint moment, and angular impulse data were calculated. Relative to an unbraced knee, braced conditions significantly increased knee flexion and adduction angles during hopping (P = 0.003 and P = 0.005; respectively), stair ascent (P = 0.003 and P < 0.001, respectively), and descent (P = 0.009 and P < 0.001, respectively). In addition, the brace conditions increased knee flexion (P < 0.001) and adduction (P = 0.001) angular impulses and knee stiffness (P < 0.001) during hopping, as well as increased knee adduction moments during stair ascent (P = 0.008) and flexion moments during stair descent (P = 0.006). There were no significant differences between the adjusted and the unadjusted brace conditions (P > 0.05). A knee brace, with or without varus alignment, can modulate knee kinematics and external joint moments during hopping, stairs ascent, and descent in individuals with predominant lateral knee osteoarthritis after ACLR. Longer-term use of a brace may have implications in slowing osteoarthritis progression.
Kinematic analysis of a posterior-stabilized knee prosthesis.
Zhao, Zhi-Xin; Wen, Liang; Qu, Tie-Bing; Hou, Li-Li; Xiang, Dong; Bin, Jia
2015-01-20
The goal of total knee arthroplasty (TKA) is to restore knee kinematics. Knee prosthesis design plays a very important role in successful restoration. Here, kinematics models of normal and prosthetic knees were created and validated using previously published data. Computed tomography and magnetic resonance imaging scans of a healthy, anticorrosive female cadaver were used to establish a model of the entire lower limbs, including the femur, tibia, patella, fibula, distal femur cartilage, and medial and lateral menisci, as well as the anterior cruciate, posterior cruciate, medial collateral, and lateral collateral ligaments. The data from the three-dimensional models of the normal knee joint and a posterior-stabilized (PS) knee prosthesis were imported into finite element analysis software to create the final kinematic model of the TKA prosthesis, which was then validated by comparison with a previous study. The displacement of the medial/lateral femur and the internal rotation angle of the tibia were analyzed during 0-135° flexion. Both the output data trends and the measured values derived from the normal knee's kinematics model were very close to the results reported in a previous in vivo study, suggesting that this model can be used for further analyses. The PS knee prosthesis underwent an abnormal forward displacement compared with the normal knee and has insufficient, or insufficiently aggressive, "rollback" compared with the lateral femur of the normal knee. In addition, a certain degree of reverse rotation occurs during flexion of the PS knee prosthesis. There were still several differences between the kinematics of the PS knee prosthesis and a normal knee, suggesting room for improving the design of the PS knee prosthesis. The abnormal kinematics during early flexion shows that the design of the articular surface played a vital role in improving the kinematics of the PS knee prosthesis.
Kanai, H
1993-07-01
A dynamic analysis was made on the knees with chronic anterior cruciate ligament (ACL) insufficiency for antero-posterior instability and abnormal rotation, also evaluating them for ground reaction force and muscle strength of knee extension. Studies were carried out on 51 patients with chronic unilateral ACL insufficiency and 80 knees of 40 healthy male and female young adults as controls. Using a knee motion analyser, an apparatus designed to analyse three dimensional knee motion, the gait was studied on a force plate. At the same time, the muscle strength of knee extension was measured with a Kinetic-Communicator (KIN-COM). In the dynamic analysis of the knee motion anterior instability was notable at a small angle of flexion. Qualitative evaluation of the knee motion revealed three patterns of rotation. The evaluation of ground reaction force showed that the rise from the heel strike was slow, its slope was gentle and the effect of weight removal was unclear. The evaluation of the muscle strength of knee extension revealed a decrease in torque of muscular contraction at 20 degrees of knee flexion.
Harry, John R; Freedman Silvernail, Julia; Mercer, John A; Dufek, Janet S
2017-12-01
Although impact phase differences between vertical jump landings (VJL) and step-off landings (STL) may be related to task-specific pre-contact strategies, pre-contact mechanics are rarely examined. Thus, pre-contact kinematics and vertical ground reaction force (vGRF) impulse were examined between VJL and STL. Ten health adults (20.9 ± 1.6 yrs; 167.8 ± 4.2 cm; 68.5 ± 7.15 kg) performed 15 VJL and 15 STL from equal heights. Limb (lead; trail) by task (VJL; STL) ANOVAs (α = 0.05) compared hip, knee, and ankle joint angles 150 ms pre-contact, 100 ms pre-contact, 50 ms pre-contact, and at ground contact. Joint angular displacement was also evaluated between 150 ms pre-contact and ground contact. vGRF impulse was compared during the loading (ground contact to peak vGRF) and attenuation (peak vGRF to end of impact) phases. Greater hip flexion angles occurred during STL versus VJL at each event except 150 ms pre-contact (p ≤ .004). Trail limb knee flexion angles were greater at each event when compared to the lead limb during STL (p ≤ .019). Greater trail limb knee flexion angles occurred during STL versus VJL at all four events (p ≤ .018), while greater plantarflexion angles occurred at all four events during VJL versus STL (p ≤ .034). During STL, greater trail limb plantarflexion angles were detected at each event versus the lead limb (p < .001). Lesser hip, lead and trail limb knee displacement occurred during STL versus VJL (p < .05). Greater vGRF impulse was detected during the loading phase of VJL (<.001), while greater vGRF impulse occurred during the attenuation phase of STL (p = .025). These tasks are characterized by distinct pre-contact kinematic strategies and post-contact kinetics. The task utilized in practice should reflect the requirements of the population of interest. Copyright © 2017 Elsevier B.V. All rights reserved.
Multijoint kinetic chain analysis of knee extension during the soccer instep kick.
Naito, Kozo; Fukui, Yosuke; Maruyama, Takeo
2010-04-01
Although previous studies have shown that motion-dependent interactions between adjacent segments play an important role in producing knee extension during the soccer instep kick, detailed knowledge about the mechanisms underlying those interactions is lacking. The present study aimed to develop a 3-D dynamical model for the multijoint kinetic chain of the instep kick in order to quantify the contributions of the causal dynamical factors to the production of maximum angular velocity during knee extension. Nine collegiate soccer players volunteered to participate in the experiment and performed instep kicking movements while 3-D positional data and the ground reaction force were measured. A dynamical model was developed in the form of a linked system containing 8 segments and 18 joint rotations, and the knee extension/flexion motion was decomposed into causal factors related to muscular moment, gyroscopic moment, centrifugal force, Coriolis force, gravity, proximal endpoint linear acceleration, and external force-dependent terms. The rapid knee extension during instep kicking was found to result almost entirely from kicking leg centrifugal force, trunk rotation muscular moment, kicking leg Coriolis force, and trunk rotation gyroscopic-dependent components. Based on the finding that rapid knee extension during instep kicking stems from multiple dynamical factors, it is suggested that the multijoint kinetic chain analysis used in the present study is more useful for achieving a detailed understanding of the cause of rapid kicking leg movement than the previously used 2-D, two-segment kinetic chain model. The present results also indicated that the centrifugal effect due to the kicking hip flexion angular velocity contributed substantially to the generation of a rapid knee extension, suggesting that the adjustment between the kicking hip flexion angular velocity and the leg configuration (knee flexion angle) is more important for effective instep kicking than other joint kinematics.
Aldridge Whitehead, Jennifer M; Wolf, Erik J; Scoville, Charles R; Wilken, Jason M
2014-10-01
Stair ascent can be difficult for individuals with transfemoral amputation because of the loss of knee function. Most individuals with transfemoral amputation use either a step-to-step (nonreciprocal, advancing one stair at a time) or skip-step strategy (nonreciprocal, advancing two stairs at a time), rather than a step-over-step (reciprocal) strategy, because step-to-step and skip-step allow the leading intact limb to do the majority of work. A new microprocessor-controlled knee (Ottobock X2(®)) uses flexion/extension resistance to allow step-over-step stair ascent. We compared self-selected stair ascent strategies between conventional and X2(®) prosthetic knees, examined between-limb differences, and differentiated stair ascent mechanics between X2(®) users and individuals without amputation. We also determined which factors are associated with differences in knee position during initial contact and swing within X2(®) users. Fourteen individuals with transfemoral amputation participated in stair ascent sessions while using conventional and X2(®) knees. Ten individuals without amputation also completed a stair ascent session. Lower-extremity stair ascent joint angles, moment, and powers and ground reaction forces were calculated using inverse dynamics during self-selected strategy and cadence and controlled cadence using a step-over-step strategy. One individual with amputation self-selected a step-over-step strategy while using a conventional knee, while 10 individuals self-selected a step-over-step strategy while using X2(®) knees. Individuals with amputation used greater prosthetic knee flexion during initial contact (32.5°, p = 0.003) and swing (68.2°, p = 0.001) with higher intersubject variability while using X2(®) knees compared to conventional knees (initial contact: 1.6°, swing: 6.2°). The increased prosthetic knee flexion while using X2(®) knees normalized knee kinematics to individuals without amputation during swing (88.4°, p = 0.179) but not during initial contact (65.7°, p = 0.002). Prosthetic knee flexion during initial contact and swing were positively correlated with prosthetic limb hip power during pull-up (r = 0.641, p = 0.046) and push-up/early swing (r = 0.993, p < 0.001), respectively. Participants with transfemoral amputation were more likely to self-select a step-over-step strategy similar to individuals without amputation while using X2(®) knees than conventional prostheses. Additionally, the increased prosthetic knee flexion used with X2(®) knees placed large power demands on the hip during pull-up and push-up/early swing. A modified strategy that uses less knee flexion can be used to allow step-over-step ascent in individuals with less hip strength.
Load balance in total knee arthroplasty: an in vitro analysis.
El-Hawary, Ron; Roth, Sandra E; King, Graham J W; Chess, David G; Johnson, James A
2006-09-01
One of the goals of total knee arthroplasty (TKA) is to balance the loads between the compartments of the knee. An instrumented load cell that measures compartment loads in real time is utilized to evaluate conventional, qualitative methods of achieving this balance. TKA was performed on 10 cadaveric knees. Prior to and after load balancing, compartment forces were measured at flexion angles of 0-90 degrees. Knees were randomly assigned into one of two groups, based upon whether or not the surgeons could visualize the load cell's output during balancing. Prior to attempting load balance, there were significant differences between the medial and lateral compartment loads for all knees (p < 0.05). After attempting balance with the aid of the load cell, there was equal load balance at all angles studied. Without the aid of the load cell, balance was not consistently achieved at every angle. Conventional load balancing techniques in TKA are not perfect. Copyright 2006 John Wiley & Sons, Ltd.
Haberfehlner, Helga; Jaspers, Richard T.; Rutz, Erich; Becher, Jules G.; Harlaar, Jaap; van der Sluijs, Johannes A.; Witbreuk, Melinda M.; Romkes, Jacqueline; Freslier, Marie; Brunner, Reinald
2016-01-01
To increase knee range of motion and improve gait in children with spastic paresis (SP), the semitendinosus muscle (ST) amongst other hamstring muscles is frequently lengthened by surgery, but with variable success. Little is known about how the pre-surgical mechanical and morphological characteristics of ST muscle differ between children with SP and typically developing children (TD). The aims of this study were to assess (1) how knee moment-angle characteristics and ST morphology in children with SP selected for medial hamstring lengthening differ from TD children, as well as (2) how knee moment-angle characteristics and ST morphology are related. In nine SP and nine TD children, passive knee moment-angle characteristics and morphology of ST (i.e. fascicle length, muscle belly length, tendon length, physiological cross-sectional area, and volume) were assessed by hand-held dynamometry and freehand 3D ultrasound, respectively. At net knee flexion moments above 0.5 Nm, more flexed knee angles were found for SP compared to TD children. The measured knee angle range between 0 and 4 Nm was 30% smaller in children with SP. Muscle volume, physiological cross-sectional area, and fascicle length normalized to femur length were smaller in SP compared to TD children (62%, 48%, and 18%, respectively). Sixty percent of the variation in knee angles at 4 Nm net knee moment was explained by ST fascicle length. Altered knee moment-angle characteristics indicate an increased ST stiffness in SP children. Morphological observations indicate that in SP children planned for medial hamstring lengthening, the longitudinal and cross-sectional growth of ST muscle fibers is reduced. The reduced fascicle length can partly explain the increased ST stiffness and, hence, a more flexed knee joint in these SP children. PMID:27861523
Haberfehlner, Helga; Jaspers, Richard T; Rutz, Erich; Becher, Jules G; Harlaar, Jaap; van der Sluijs, Johannes A; Witbreuk, Melinda M; Romkes, Jacqueline; Freslier, Marie; Brunner, Reinald; Maas, Huub; Buizer, Annemieke I
2016-01-01
To increase knee range of motion and improve gait in children with spastic paresis (SP), the semitendinosus muscle (ST) amongst other hamstring muscles is frequently lengthened by surgery, but with variable success. Little is known about how the pre-surgical mechanical and morphological characteristics of ST muscle differ between children with SP and typically developing children (TD). The aims of this study were to assess (1) how knee moment-angle characteristics and ST morphology in children with SP selected for medial hamstring lengthening differ from TD children, as well as (2) how knee moment-angle characteristics and ST morphology are related. In nine SP and nine TD children, passive knee moment-angle characteristics and morphology of ST (i.e. fascicle length, muscle belly length, tendon length, physiological cross-sectional area, and volume) were assessed by hand-held dynamometry and freehand 3D ultrasound, respectively. At net knee flexion moments above 0.5 Nm, more flexed knee angles were found for SP compared to TD children. The measured knee angle range between 0 and 4 Nm was 30% smaller in children with SP. Muscle volume, physiological cross-sectional area, and fascicle length normalized to femur length were smaller in SP compared to TD children (62%, 48%, and 18%, respectively). Sixty percent of the variation in knee angles at 4 Nm net knee moment was explained by ST fascicle length. Altered knee moment-angle characteristics indicate an increased ST stiffness in SP children. Morphological observations indicate that in SP children planned for medial hamstring lengthening, the longitudinal and cross-sectional growth of ST muscle fibers is reduced. The reduced fascicle length can partly explain the increased ST stiffness and, hence, a more flexed knee joint in these SP children.
Does high knee flexion cause separation of meniscal repairs?
Lin, David L; Ruh, Sarah S; Jones, Hugh L; Karim, Azim; Noble, Philip C; McCulloch, Patrick C
2013-09-01
Previous clinical studies comparing nonrestrictive and restrictive protocols after meniscal repair have shown no difference in outcomes; however, some surgeons still limit range of motion out of concern that it will place undue stress on the repair. Large acute medial meniscal tears will gap during simulated open chain exercises at high flexion angles, and a repaired construct with vertical mattress sutures will not gap. Controlled laboratory study. Tantalum beads were implanted in the medial menisci of 6 fresh-frozen cadaveric knees via an open posteromedial approach. Each knee underwent 10 simulated open chain flexion cycles with loading of the quadriceps and hamstrings. Testing was performed on 3 different states of the meniscus: intact, torn, and repaired. Biplanar radiographs were taken of the loaded knee in 90°, 110°, and 135° of flexion for each state. A 2.5-cm tear was created in the posteromedial meniscus and repaired with inside-out vertical mattress sutures. Displacement of pairs of beads spanning the tear was measured in all planes by use of radiostereometric analysis (RSA) with an accuracy of better than 80 μm. With a longitudinal tear, compression rather than gapping occurred in all 3 regions of the posterior horn of the meniscus (mean ± standard deviation for medial collateral ligament [MCL], -321 ± 320 μm; midposterior, -487 ± 256 μm; root, -318 ± 150 μm) with knee flexion. After repair, meniscal displacement returned part way to intact values in both the MCL (+55 ± 250 μm) and root region (-170 ± 123 μm) but not the midposterior region, where further compression was seen (-661 ± 278 μm). Acute posteromedial meniscal tears and repairs with vertical mattress sutures do not gap, but rather compress in the transverse plane at higher flexion angles when subjected to physiologic loads consistent with active, open kinetic chain range of motion rehabilitation exercises. The kinematics of the repaired meniscus more closely resemble that of the intact meniscus than that of the torn meniscus in regions adjacent to the MCL and the root but not in the midposterior region, where meniscal repair led to increased compression across the tear plane. This study supports the idea that nonrestrictive unresisted open chain range of motion protocols do not place undue stress on meniscal repairs.
Matsuda, Mayumi; Mataki, Yuki; Mutsuzaki, Hirotaka; Yoshikawa, Kenichi; Takahashi, Kazushi; Enomoto, Keiko; Sano, Kumiko; Mizukami, Masafumi; Tomita, Kazuhide; Ohguro, Haruka; Iwasaki, Nobuaki
2018-01-01
[Purpose] Robot-assisted gait training (RAGT) using Hybrid Assistive Limb (HAL, CYBERDYNE) was previously reported beneficial for stroke and spinal cord injury patients. Here, we investigate the immediate effect of a single session of RAGT using HAL on gait function for cerebral palsy (CP) patients. [Subjects and Methods] Twelve patients (average age: 16.2 ± 7.3 years) with CP received a single session of RAGT using HAL. Gait speed, step length, cadence, single-leg support per gait cycle, hip and knee joint angle in stance, and swing phase per gait cycle were assessed before, during, and immediately after HAL intervention. [Results] Compared to baseline values, single-leg support per gait cycle (64.5 ± 15.8% to 69.3 ± 12.1%), hip extension angle in mid-stance (149.2 ± 19.0° to 155.5 ± 20.1°), and knee extension angle in mid-stance (137.6 ± 20.2° to 143.1 ± 19.5°) were significantly increased immediately after intervention. Further, the knee flexion angle in mid-swing was significantly decreased immediately after treatment (112.0 ± 15.5° to 105.2 ± 17.1°). Hip flexion angle in mid-swing also decreased following intervention (137.2 ± 14.6° to 129.7 ± 16.6°), but not significantly. Conversely, gait speed, step length, and cadence were unchanged after intervention. [Conclusion] A single-time RAGT with HAL improved single-leg support per gait cycle and hip and knee joint angle during gait, therapeutically improving gait function in CP patients. PMID:29545679
Matsuda, Mayumi; Mataki, Yuki; Mutsuzaki, Hirotaka; Yoshikawa, Kenichi; Takahashi, Kazushi; Enomoto, Keiko; Sano, Kumiko; Mizukami, Masafumi; Tomita, Kazuhide; Ohguro, Haruka; Iwasaki, Nobuaki
2018-02-01
[Purpose] Robot-assisted gait training (RAGT) using Hybrid Assistive Limb (HAL, CYBERDYNE) was previously reported beneficial for stroke and spinal cord injury patients. Here, we investigate the immediate effect of a single session of RAGT using HAL on gait function for cerebral palsy (CP) patients. [Subjects and Methods] Twelve patients (average age: 16.2 ± 7.3 years) with CP received a single session of RAGT using HAL. Gait speed, step length, cadence, single-leg support per gait cycle, hip and knee joint angle in stance, and swing phase per gait cycle were assessed before, during, and immediately after HAL intervention. [Results] Compared to baseline values, single-leg support per gait cycle (64.5 ± 15.8% to 69.3 ± 12.1%), hip extension angle in mid-stance (149.2 ± 19.0° to 155.5 ± 20.1°), and knee extension angle in mid-stance (137.6 ± 20.2° to 143.1 ± 19.5°) were significantly increased immediately after intervention. Further, the knee flexion angle in mid-swing was significantly decreased immediately after treatment (112.0 ± 15.5° to 105.2 ± 17.1°). Hip flexion angle in mid-swing also decreased following intervention (137.2 ± 14.6° to 129.7 ± 16.6°), but not significantly. Conversely, gait speed, step length, and cadence were unchanged after intervention. [Conclusion] A single-time RAGT with HAL improved single-leg support per gait cycle and hip and knee joint angle during gait, therapeutically improving gait function in CP patients.
Balanced Flexion and Extension Gaps Are Not Always of Equal Size.
Kinsey, Tracy L; Mahoney, Ormonde M
2018-04-01
It has been widely accepted in total knee arthroplasty (TKA) that flexion and extension gaps in the disarticulated knee during surgery should be equalized. We hypothesized that tensioning during assessment of the flexion gap can induce temporary widening of the gap due to posterior tibial translation. We aimed to describe posterior tibial translation at flexion gap (90°) assessments and assess the correlation of tibial translation with laxity (flexion space increase) using constrained and non-constrained inserts. Imageless navigation was used to measure flexion angle, tibial position relative to the femoral axis, and lateral/medial laxity in 30 patients undergoing primary TKA. Trialing was conducted using posteriorly stabilized and cruciate retaining trials of the same size to elucidate the association of posterior tibial translation with changes in joint capsule laxity at 90° knee flexion. All patients demonstrated posterior tibial translation during flexion gap assessment relative to their subsequent final implantation [mean ± standard deviation (range), 11.3 ± 4.4 (4-21) mm]. Positive linear correlation [r = 0.69, 95% confidence interval (CI) 0.44-0.84, P ≤ .001] was demonstrated between translations [8.7 ± 2.4 (3-13) mm] and laxity changes [2.9° ± 2.0° (-0.7° to 7.4°)] at 90° of flexion. Posterior tibial translation can cause artifactual widening of the flexion gap during gap balancing in posteriorly stabilized TKA, which can be of sufficient magnitude to alter femoral component size selection for some patients. Recognition and management of these intra-operative dynamics for optimal kinematics could be feasible with the advent of robotic applications. Copyright © 2017 Elsevier Inc. All rights reserved.
Wahal, Naman; Gaba, Sahil; Malhotra, Rajesh; Kumar, Vijay; Pegg, Elise C; Pandit, Hemant
2018-02-01
A small proportion of patients with mobile unicompartmental knee arthroplasty (UKA) report poor functional outcomes in spite of optimal component alignment on postoperative radiographs. The purpose of this study is to assess whether there is a correlation between functional outcome and knee kinematics. From a cohort of consecutive cases of 150 Oxford medial UKA, patients with fair/poor functional outcome at 1-year postsurgery (Oxford Knee Score [OKS] < 34, n = 15) were identified and matched for age, gender, preoperative clinical scores, and follow-up period with a cohort of patients with good/excellent outcome (OKS ≥ 34, n = 15). In vivo kinematic assessment was performed using step-up and deep knee bend exercises under fluoroscopic imaging. The fluoroscopic videos were analyzed using MATLAB software to measure the variation in time taken to complete the exercises, patellar tendon angle, and bearing position with knee flexion angle. Mean OKS in the fair/poor group was 29.9 and the mean OKS in the good/excellent group was 41.1. The tibial slope, time taken to complete the exercises, and patellar tendon angle trend over the flexion range were similar in both the groups; however, bearing position and the extent of bearing excursion differed significantly. The total bearing excursion in the OKS < 34 group was significantly smaller than the OKS ≥ 34 group (35%). Furthermore, on average, the bearing was positioned 1.7 mm more posterior on the tibia in the OKS < 34 group. This study provides evidence that abnormal knee kinematics, in particular bearing excursion and positioning, are associated with worse functional outcomes after mobile UKA. Copyright © 2017 Elsevier Inc. All rights reserved.
Instruction and jump-landing kinematics in college-aged female athletes over time.
Etnoyer, Jena; Cortes, Nelson; Ringleb, Stacie I; Van Lunen, Bonnie L; Onate, James A
2013-01-01
Instruction can be used to alter the biomechanical movement patterns associated with anterior cruciate ligament (ACL) injuries. To determine the effects of instruction through combination (self and expert) feedback or self-feedback on lower extremity kinematics during the box-drop-jump task, running-stop-jump task, and sidestep-cutting maneuver over time in college-aged female athletes. Randomized controlled clinical trial. Laboratory. Forty-three physically active women (age = 21.47 ± 1.55 years, height = 1.65 ± 0.08 m, mass = 63.78 ± 12.00 kg) with no history of ACL or lower extremity injuries or surgery in the 2 months before the study were assigned randomly to 3 groups: self-feedback (SE), combination feedback (CB), or control (CT). Participants performed a box-drop-jump task for the pretest and then received feedback about their landing mechanics. After the intervention, they performed an immediate posttest of the box-drop-jump task and a running-stop-jump transfer test. Participants returned 1 month later for a retention test of each task and a sidestep-cutting maneuver. Kinematic data were collected with an 8-camera system sampled at 500 Hz. The independent variables were feedback group (3), test time (3), and task (3). The dependent variables were knee- and hip-flexion, knee-valgus, and hip- abduction kinematics at initial contact and at peak knee flexion. For the box-drop-jump task, knee- and hip-flexion angles at initial contact were greater at the posttest than at the retention test (P < .001). At peak knee flexion, hip flexion was greater at the posttest than at the pretest (P = .003) and was greater at the retention test than at the pretest (P = .04); knee valgus was greater at the retention test than at the pretest (P = .03) and posttest (P = .02). Peak knee flexion was greater for the CB than the SE group (P = .03) during the box-drop-jump task at posttest. For the running-stop-jump task at the posttest, the CB group had greater peak knee flexion than the SE and CT (P ≤ .05). Our results suggest that feedback involving a combination of self-feedback and expert video feedback with oral instruction effectively improved lower extremity kinematics during jump-landing tasks.
Instruction and Jump-Landing Kinematics in College-Aged Female Athletes Over Time
Etnoyer, Jena; Cortes, Nelson; Ringleb, Stacie I.; Van Lunen, Bonnie L.; Onate, James A.
2013-01-01
Context: Instruction can be used to alter the biomechanical movement patterns associated with anterior cruciate ligament (ACL) injuries. Objective: To determine the effects of instruction through combination (self and expert) feedback or self-feedback on lower extremity kinematics during the box–drop-jump task, running–stop-jump task, and sidestep-cutting maneuver over time in college-aged female athletes. Design: Randomized controlled clinical trial. Setting: Laboratory. Patients or Other Participants: Forty-three physically active women (age = 21.47 ± 1.55 years, height = 1.65 ± 0.08 m, mass = 63.78 ± 12.00 kg) with no history of ACL or lower extremity injuries or surgery in the 2 months before the study were assigned randomly to 3 groups: self-feedback (SE), combination feedback (CB), or control (CT). Intervention(s): Participants performed a box–drop-jump task for the pretest and then received feedback about their landing mechanics. After the intervention, they performed an immediate posttest of the box–drop-jump task and a running–stop-jump transfer test. Participants returned 1 month later for a retention test of each task and a sidestep-cutting maneuver. Kinematic data were collected with an 8-camera system sampled at 500 Hz. Main Outcome Measure(s): The independent variables were feedback group (3), test time (3), and task (3). The dependent variables were knee- and hip-flexion, knee-valgus, and hip- abduction kinematics at initial contact and at peak knee flexion. Results: For the box–drop-jump task, knee- and hip-flexion angles at initial contact were greater at the posttest than at the retention test (P < .001). At peak knee flexion, hip flexion was greater at the posttest than at the pretest (P = .003) and was greater at the retention test than at the pretest (P = .04); knee valgus was greater at the retention test than at the pretest (P = .03) and posttest (P = .02). Peak knee flexion was greater for the CB than the SE group (P = .03) during the box–drop-jump task at posttest. For the running–stop-jump task at the posttest, the CB group had greater peak knee flexion than the SE and CT (P ≤ .05). Conclusions: Our results suggest that feedback involving a combination of self-feedback and expert video feedback with oral instruction effectively improved lower extremity kinematics during jump-landing tasks. PMID:23672380
Xu, Yi; Hou, Qinghua; Wang, Chuhuai; Sellers, Andrew J; Simpson, Travis; Bennett, Bradford C; Russell, Shawn D
2017-01-01
Barefoot technology shoes are becoming increasingly popular, yet modifications are still needed. The present study aims to gain valuable insights by comparing barefoot walking to neutral shoe walking in a healthy youth population. 28 healthy university students (22 females and 6 males) were recruited to walk on a 10-meter walkway both barefoot and in neutral running shoes at their comfortable walking speed. Full step cycle kinematic and kinetic data were collected using an 8-camera motion capture system. In the early stance phase, the knee extension moment (MK1), the first peak absorbed joint power at the knee joint (PK1), and the flexion angle of knee/dorsiflexion angle of the ankle were significantly reduced when walking in neutral running shoes. However, in the late stance, barefoot walking resulted in decreased hip joint flexion moment (MH2), second peak extension knee moment (MK3), hip flexors absorbed power (PH2), hip flexors generated power (PH3), second peak absorbed power by knee flexors (PK2), and second peak anterior-posterior component of joint force at the hip (APFH2), knee (APFK2), and ankle (APFA2). These results indicate that it should be cautious to discard conventional elements from future running shoe designs and rush to embrace the barefoot technology fashion.
Daglar, Bulent; Gungor, Ertugrul; Delialioglu, Onder M; Karakus, Dilek; Ersoz, Murat; Tasbas, Bulent Adil; Bayrakci, Kenan; Gunel, Ugur
2009-10-01
To evaluate knee function in patients having femoral diaphyseal fractures treated with antegrade or retrograde intramedullary nail insertion. Prospective. Level I referral center. Seventy patients having 71 OTA 32 fractures were randomly allocated into 2 groups to be treated with either antegrade or retrograde intramedullary nails inserted with reaming. Antegrade nail in 41 fractures and retrograde femoral intramedullary nails in 30 fractures. Postoperative knee range of motion, Lysholm Knee Score, and isokinetic knee muscle function testing at least 6 months after documented fracture healing, minimum 1 year postoperatively. Groups had similar data with regard to demographics and injury patterns. Mean follow-up time was 44 (range: 25-80) months. Mean knee flexion angle was 132 and 134 degrees, and mean Lysholm Score was 84 and 83.1 in antegrade and retrograde groups, respectively (P = 0.893 and P = 0.701). Isokinetic evaluation revealed similar results for peak torque deficiencies at 30 and 180 degrees per second and total work deficiencies at 180 degrees per second (P > 0.05). Age affected the knee functioning as the higher the age of the patient is, the lower the Lysholm Score and knee flexion angle (r = -0.449, P = 0.0321 and r = -0.568, P = 0.001, respectively). Knee function seems to have similar clinical results after either antegrade or retrograde nail insertion for femoral diaphyseal fractures when knee range of motion, Lysholm Scores, and isokinetic knee evaluation are considered as outcome measures. With increasing patient age, a decrease in knee functioning should be anticipated in patients with femoral fractures treated with intramedullary nails regardless of technique.
Stock, J D; Calderón Díaz, J A; Rothschild, M F; Mote, B E; Stalder, K J
2018-06-09
Feet and legs of replacement females were objectively evaluated at selection, i.e. approximately 150 days of age (n=319) and post first parity, i.e. any time after weaning of first litter and before 2nd parturition (n=277) to 1) compare feet and leg joint angle ranges between selection and post first parity; 2) identify feet and leg joint angle differences between selection and first three weeks of second gestation; 3) identify feet and leg join angle differences between farms and gestation days during second gestation; and 4) obtain genetic variance components for conformation angles for the two time points measured. Angles for carpal joint (knee), metacarpophalangeal joint (front pastern), metatarsophalangeal joint (rear pastern), tarsal joint (hock), and rear stance were measured using image analysis software. Between selection and post first parity significant differences were observed for all joints measured (P < 0.05). Knee, front and rear pastern angles were less (more flexion), and hock angles were greater (less flexion) as age progressed (P < 0.05), while the rear stance pattern was less (feet further under center) at selection than post first parity (only including measures during first three weeks of second gestation). Only using post first parity leg conformation information, farm was a significant source of variation for front and rear pasterns and rear stance angle measurements (P < 0.05). Knee angle was less (more flexion) (P < 0.05) as gestation age progressed. Heritability estimates were low to moderate (0.04 - 0.35) for all traits measured across time points. Genetic correlations between the same joints at different time points were high (> 0.8) between the front leg joints and low (<0.2) between the rear leg joints. High genetic correlations between time points indicate that the trait can be considered the same at either time point, and low genetic correlations indicate that the trait at different time points should be considered as two separate traits. Minimal change in the front leg suggests conformation traits that remain between selection and post first parity, while larger changes in rear leg indicate that rear leg conformation traits should be evaluated at multiple time periods.
Chmielewski, T L; Ramsey, D K; Snyder-Mackler, L
2005-01-01
Functional outcomes in anterior cruciate ligament-deficient "potential copers" and "non-copers" may be related to their knee stabilization strategies. Therefore, the purpose of this study was to differentiate dynamic knee stabilization strategies of potential copers and non-copers through analysis of sagittal plane knee angle and tibia position during disturbed and undisturbed unilateral standing. Ten uninjured potential coper and non-coper subjects stood in unilateral stance on a platform that translated anteriorly, posteriorly and laterally. Knee angle and tibia position with reference to the femur were calculated before and after platform movement. During perturbation trials, potential copers maintained kinematics that were similar to uninjured subjects across conditions. Conversely, non-copers stood with greater knee flexion than uninjured subjects and a tibia position that was more posterior than the other groups. Both non-copers and potential copers demonstrated small changes in tibia position following platform movement, but direction of movement was not similar. The similarities between the knee kinematics of potential copers and uninjured subjects suggest that potential copers compensated well from their injury by utilizing analogous dynamic knee stabilization strategies. In comparison to the other groups, by keeping the knee in greater flexion and the tibia in a more posterior position, non-copers appear to constrain the tibia in response to a challenging task, which is consistent with a "stiffening strategy". Based on the poor functional outcomes of non-copers, a stiffening strategy does not lead to dynamic knee stability, and the strategy may increase compressive forces which could contribute to or exacerbate articular cartilage degeneration.
Tengman, E; Grip, H; Stensdotter, Ak; Häger, C K
2015-12-01
Reduced dynamic knee stability, often evaluated with one-leg hops (OLHs), is reported after anterior cruciate ligament (ACL) injury. This may lead to long-standing altered movement patterns, which are less investigated. 3D kinematics during OLH were explored in 70 persons 23 ± 2 years after ACL injury; 33 were treated with physiotherapy in combination with ACL reconstruction (ACL(R)) and 37 with physiotherapy alone (ACL(PT)). Comparisons were made to 33 matched controls. We analyzed (a) maximal knee joint angles and range of motion (flexion, abduction, rotation); (b) medio-lateral position of the center of mass (COM) in relation to knee and ankle joint centers, during take-off and landing phases. Unlike controls, ACL-injured displayed leg asymmetries: less knee flexion and less internal rotation at take-off and landing and more lateral COM related to knee and ankle joint of the injured leg at landing. Compared to controls, ACL(R) had larger external rotation of the injured leg at landing. ACL(PT) showed less knee flexion and larger external rotation at take-off and landing, and larger knee abduction at Landing. COM was more medial in relation to the knee at take-off and less laterally placed relative to the ankle at landing. ACL injury results in long-term kinematic alterations during OLH, which are less evident for ACL(R). © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Lessi, Giovanna Camparis; Dos Santos, Ana Flávia; Batista, Luis Fylipe; de Oliveira, Gabriela Clemente; Serrão, Fábio Viadanna
2017-02-01
Muscle fatigue is associated with biomechanical changes that may lead to anterior cruciate ligament (ACL) injuries. Alterations in trunk and pelvis kinematics may also be involved in ACL injury. Although some studies have compared the effects of muscle fatigue on lower limb kinematics between men and women, little is known about its effects on pelvis and trunk kinematics. The aim of the study was to compare the effects of fatigue on lower limb, pelvis and trunk kinematics and muscle activation between men and women during landing. The participants included forty healthy subjects. We performed kinematic analysis of the trunk, pelvis, hip and knee and muscle activation analysis of the gluteal muscles, vastus lateralis and biceps femoris, during a single-leg landing before and after fatigue. Men had greater trunk flexion than women after fatigue. After fatigue, a decrease in peak knee flexion and an increase in Gmax and BF activation were observed. The increase in the trunk flexion can decrease the anterior tibiofemoral shear force resulted from the lower knee flexion angle, thereby decreasing the stress on the ACL. Copyright © 2016 Elsevier Ltd. All rights reserved.
De Coninck, Tineke; Elsner, Jonathan J; Linder-Ganz, Eran; Cromheecke, Michiel; Shemesh, Maoz; Huysse, Wouter; Verdonk, René; Verstraete, Koenraad; Verdonk, Peter
2014-09-01
In this pilot study we wanted to evaluate the kinematics of a knee implanted with an artificial polycarbonate-urethane meniscus device, designed for medial meniscus replacement. The static kinematic behavior of the implant was compared to the natural medial meniscus of the non-operated knee. A second goal was to evaluate the motion pattern, the radial displacement and the deformation of the meniscal implant. Three patients with a polycarbonate-urethane implant were included in this prospective study. An open-MRI was used to track the location of the implant during static weight-bearing conditions, within a range of motion of 0° to 120° knee flexion. Knee kinematics were evaluated by measuring the tibiofemoral contact points and femoral roll-back. Meniscus measurements (both natural and artificial) included anterior-posterior meniscal movement, radial displacement, and meniscal height. No difference (P>0.05) was demonstrated in femoral roll-back and tibiofemoral contact points during knee flexion between the implanted and the non-operated knees. Meniscal measurements showed no significant difference in radial displacement and meniscal height (P>0.05) at all flexion angles, in both the implanted and non-operated knees. A significant difference (P ≤ 0.05) in anterior-posterior movement during flexion was observed between the two groups. In this pilot study, the artificial polycarbonate-urethane implant, indicated for medial meniscus replacement, had no influence on femoral roll-back and tibiofemoral contact points, thus suggesting that the joint maintains its static kinematic properties after implantation. Radial displacement and meniscal height were not different, but anterior-posterior movement was slightly different between the implant and the normal meniscus. Copyright © 2014 Elsevier Ltd. All rights reserved.
Chain-loaded variable resistance warm-up improves free-weight maximal back squat performance.
Mina, Minas A; Blazevich, Anthony J; Giakas, Giannis; Seitz, Laurent B; Kay, Anthony D
2016-11-01
The acute influence of chain-loaded variable resistance exercise on subsequent free-weight one-repetition maximum (1-RM) back squat performance was examined in 16 recreationally active men. The participants performed either a free-weight resistance (FWR) or chain-loaded resistance (CLR) back squat warm-up at 85% 1-RM on two separate occasions. After a 5-min rest, the participants attempted a free-weight 1-RM back squat; if successful, subsequent 5% load additions were made until participants failed to complete the lift. During the 1-RM trials, 3D knee joint kinematics and knee extensor and flexor electromyograms (EMG) were recorded simultaneously. Significantly greater 1-RM (6.2 ± 5.0%; p < .01) and mean eccentric knee extensor EMG (32.2 ± 6.7%; p < .01) were found after the CLR warm-up compared to the FWR condition. However, no difference (p > .05) was found in concentric EMG, eccentric or concentric knee angular velocity, or peak knee flexion angle. Performing a CLR warm-up enhanced subsequent free-weight 1-RM performance without changes in knee flexion angle or eccentric and concentric knee angular velocities; thus a real 1-RM increase was achieved as the mechanics of the lift were not altered. These results are indicative of a potentiating effect of CLR in a warm-up, which may benefit athletes in tasks where high-level strength is required.
Modification of the Grood and Suntay Joint Coordinate System equations for knee joint flexion.
Dabirrahmani, Danè; Hogg, Michael
2017-01-01
Since its introduction, the Grood and Suntay Joint Coordinate System (JCS) has been embraced by the International Society of Biomechanics (ISB) and been widely used for biomechanical reporting. There is, however, a limitation in its ability to provide correct flexion values over a wide range of clinically relevant flexion angles. This technical note addresses the limitation of the JCS equations and introduces a new set of equations to overcome this problem. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Hartmann, Hagen; Wirth, Klaus; Klusemann, Markus
2013-10-01
It has been suggested that deep squats could cause an increased injury risk of the lumbar spine and the knee joints. Avoiding deep flexion has been recommended to minimize the magnitude of knee-joint forces. Unfortunately this suggestion has not taken the influence of the wrapping effect, functional adaptations and soft tissue contact between the back of thigh and calf into account. The aim of this literature review is to assess whether squats with less knee flexion (half/quarter squats) are safer on the musculoskeletal system than deep squats. A search of relevant scientific publications was conducted between March 2011 and January 2013 using PubMed. Over 164 articles were included in the review. There are no realistic estimations of knee-joint forces for knee-flexion angles beyond 50° in the deep squat. Based on biomechanical calculations and measurements of cadaver knee joints, the highest retropatellar compressive forces and stresses can be seen at 90°. With increasing flexion, the wrapping effect contributes to an enhanced load distribution and enhanced force transfer with lower retropatellar compressive forces. Additionally, with further flexion of the knee joint a cranial displacement of facet contact areas with continuous enlargement of the retropatellar articulating surface occurs. Both lead to lower retropatellar compressive stresses. Menisci and cartilage, ligaments and bones are susceptible to anabolic metabolic processes and functional structural adaptations in response to increased activity and mechanical influences. Concerns about degenerative changes of the tendofemoral complex and the apparent higher risk for chondromalacia, osteoarthritis, and osteochondritis in deep squats are unfounded. With the same load configuration as in the deep squat, half and quarter squat training with comparatively supra-maximal loads will favour degenerative changes in the knee joints and spinal joints in the long term. Provided that technique is learned accurately under expert supervision and with progressive training loads, the deep squat presents an effective training exercise for protection against injuries and strengthening of the lower extremity. Contrary to commonly voiced concern, deep squats do not contribute increased risk of injury to passive tissues.
Lemaire, Edward D; Samadi, Reza; Goudreau, Louis; Kofman, Jonathan
2013-01-01
A linear piston hydraulic angular-velocity-based control knee joint was designed for people with knee-extensor weakness to engage knee-flexion resistance when knee-flexion angular velocity reaches a preset threshold, such as during a stumble, but to otherwise allow free knee motion. During mechanical testing at the lowest angular-velocity threshold, the device engaged within 2 degrees knee flexion and resisted moment loads of over 150 Nm. The device completed 400,000 loading cycles without mechanical failure or wear that would affect function. Gait patterns of nondisabled participants were similar to normal at walking speeds that produced below-threshold knee angular velocities. Fast walking speeds, employed purposely to attain the angular-velocity threshold and cause knee-flexion resistance, reduced maximum knee flexion by approximately 25 degrees but did not lead to unsafe gait patterns in foot ground clearance during swing. In knee collapse tests, the device successfully engaged knee-flexion resistance and stopped knee flexion with peak knee moments of up to 235.6 Nm. The outcomes from this study support the potential for the linear piston hydraulic knee joint in knee and knee-ankle-foot orthoses for people with lower-limb weakness.
Knee Brace Would Lock And Unlock Automatically
NASA Technical Reports Server (NTRS)
Myers, Neill; Forbes, John; Shadoan, Mike; Baker, Kevin
1995-01-01
Proposed knee brace designed to aid rehabilitation of person who suffered some muscle damage in leg. Not limited to locking in straight-leg position and, instead, locks at any bend angle. Does not prevent knee from bearing weight. Instead, knee brace allows knee to bear weight and locks only when foot and lower leg bear weight. Thus, brace prevents flexion that wearer desired to prevent but could not prevent because of weakened muscles. Knee bends freely to exercise knee-related muscles. Knee brace strapped at upper end to leg above knee, and anchored at lower end by stirrup under foot. Joint mechanism (identical mechanisms used in left and right assemblies) allows knee joint to flex freely except when weight applied to heel.
Favre, Julien; Jolles, Brigitte M.
2016-01-01
Knee osteoarthritis (OA) is a painful and incapacitating disease affecting a large portion of the elderly population, for which no cure exists. There is a critical need to enhance our understanding of OA pathogenesis, as a means to improve therapeutic options. Knee OA is a complex disease influenced by many factors, including the loading environment. Analysing knee biomechanics during walking - the primary cyclic load-bearing activity - is therefore particularly relevant. There is evidence of meaningful differences in the knee adduction moment, flexion moment and flexion angle during walking between non-OA individuals and patients with medial knee OA. Furthermore, these kinetic and kinematic gait variables have been associated with OA progression. Gait analysis provides the critical information needed to understand the role of ambulatory biomechanics in OA development, and to design therapeutic interventions. Multidisciplinary research is necessary to relate the biomechanical alterations to the structural and biological components of OA. Cite this article: Favre J, Jolles BM. Analysis of gait, knee biomechanics and the physiopathology of knee osteoarthritis in the development of therapeutic interventions. EFORT Open Rev 2016;1:368-374. DOI: 10.1302/2058-5241.1.000051. PMID:28461915
Pressure-volume relationships and elastance in the knee joint of the dog.
Nade, S; Newbold, P J
1984-12-01
This study has investigated changes in intra-articular hydrostatic pressure in the knee joints of normal dogs in response to continuous and stepwise infusions of fluids. The relationship between pressure and volume in the joint was examined over the pressure range of -8 to +50 mmHg, and also at much higher pressures often associated with joint disease or injury. The effects of joint angle and dog weight on the pressure-volume relationship and on elastance of the dogs' knees were also examined. With liquid paraffin B.P. the pressure was found to increase more with each unit volume infused at subatmospheric pressures than at pressures around atmospheric, and increased more again at higher pressures. The pressure-volume curve with saline infusions was affected by egress of fluid from the joint at supra-atmospheric pressure. Above +5 mmHg the rise in pressure per unit volume infused was less than that for paraffin at the same volume. Elastance and compliance of the normal joint capsule were calculated from the pressure-volume data. Elastance was high at subatmospheric pressures, decreased rapidly as atmospheric pressure was approached and rose as a linear function of pressure above 12 mmHg. The biphasic shape of the elastance-pressure curve is discussed, and explanations for the shape are suggested. After intra-articular pressure in the knee was raised by infusion of paraffin oil the joint was moved through the range of positions from 125 deg extension to 50 deg flexion. Intra-articular pressure did not change across the range 125-110 deg. However, increasing the angle of flexion from 110 to 50 deg resulted in a rise in pressure which became steeper for each volume increment. Increasing intra-articular fluid volume caused a decrease in the total range of movement of the joint. The pressure-volume curves measured at extended angles of 110, 125 and 140 deg, where the starting pressures were subatmospheric, were the same. At flexed joint positions of 80 and 50 deg, where the starting pressures were supra-atmospheric, the pressure-volume curves became steeper with greater flexion. Elastance of the joint tissues increased with flexion. The elastance at each joint angle depended also on the volume or pressure. Significant differences were found to exist between pressure-volume curves for three groups of animals of different weight.(ABSTRACT TRUNCATED AT 400 WORDS)
Demoulin, Christophe; Wolfs, Sébastien; Chevalier, Madeline; Granado, Caroline; Grosdent, Stéphanie; Depas, Yannick; Roussel, Nathalie; Hage, Renaud; Vanderthommen, Marc
2016-01-01
Most parameters regarding hamstring flexibility training programs have been investigated; however, the joint (i.e. hip or knee) on which the stretching should preferentially be focused needs to be further explored. This randomized controlled assessor-blinded study aimed to investigate the influence of this parameter. We randomly assigned 111 asymptomatic participants with tight hamstring muscles in three groups: a control group and two groups following a different home-based 8-week (five 10-minute sessions per week) hamstring stretching program (i.e. stretching performed by flexing the hip while keeping the knee extended [SH] or by first flexing the hip with a flexed knee and then extending the knee [SK]). Range of motion (ROM) of hip flexion and knee extension were measured before and after the stretching program by means of the straight leg raising test and the passive knee extension angle test, respectively. Eighty-nine participants completed the study. A significant increase in ROM was observed at post-test. Analyses showed significant group-by-time interactions for changes regarding all outcomes. Whereas the increase in hip flexion and knee extension ROM was higher in the stretching groups than in the CG (especially for the SH group p < 0.05), no differences between the two stretching groups were observed (p > 0.05). In conclusion, the fact that both stretching programs resulted in similar results suggests no influence of the joint at which the stretching is focused upon, as assessed by the straight leg raising and knee extension angle tests.
Bauer, T; Biau, D; Colmar, M; Poux, X; Hardy, P; Lortat-Jacob, A
2010-12-01
The range of motion of the knee joint after Total Knee Replacement (TKR) is a factor of great importance that determines the postoperative function of patients. Much enthusiasm has been recently directed towards the posterior condylar offset with some authors reporting increasing postoperative knee flexion with increasing posterior condylar offset and others who did not report any significant association. Patients undergoing primary total knee replacement were included in a prospective multicentre study and the effect of the posterior condylar offset on the postoperative knee flexion was assessed after adjusting for known influential factors. All knees were implanted by three senior orthopedist surgeons with the same cemented cruciate-sacrificing mobile-bearing implant and with identical surgical technique. Clinical data, active knee flexion and posterior condylar offset were recorded preoperatively and postoperatively at a minimal one year follow-up for all patients. Univariate and multivariate linear models were fitted to select independent predictors of the postoperative knee flexion. Four hundred and ten consecutive total knee replacements (379 patients) were included in the study. The mean preoperative knee flexion was 112°. The mean condylar offset was 28.3mm preoperatively and 29.4mm postoperatively. The mean postoperative knee flexion was 108°. No correlation was found between the posterior condylar offset or the tibial slope and the postoperative knee flexion. The most significant predictive factor for postoperative flexion after posterior-stabilized TKR without PCL retention was the preoperative range of flexion, with a linear effect. Copyright © 2009 Elsevier B.V. All rights reserved.
Kimura, Yuka; Ishibashi, Yasuyuki; Tsuda, Eiichi; Yamamoto, Yuji; Hayashi, Yoshimitsu; Sato, Shuichi
2012-03-01
In badminton, knees opposite to the racket-hand side received anterior cruciate ligament (ACL) injuries during single-leg landing after overhead stroke. Most of them occurred in the backhand-side of the rear court. Comparing lower limb biomechanics during single-leg landing after overhead stroke between the forehand-side and backhand-side court may help explain the different injury rates depending on court position. The knee kinematics and kinetics during single-leg landing after overhead stroke following back-stepping were different between the forehand-side and backhand-side court. Controlled laboratory study. Hip, knee and ankle joint kinematic and knee kinetic data were collected for 17 right-handed female college badminton players using a 3-dimensional motion analysis system. Subjects performed single-left-legged landing after an overhead stroke following left and right back-stepping. The kinematic and kinetic data of the left lower extremities during landing were measured and compared between left and right back-steps. Hip flexion and abduction and knee valgus at the initial contact, hip and knee flexion and knee valgus at the maximum knee flexion and the maximum knee valgus moment were significantly larger for the left back-step than the right back-step (p<0.05). Significant differences in joint kinematics and kinetics of the lower extremity during single-leg landing after overhead stroke were observed between different back-step directions. Increased knee valgus angle and moment following back-stepping to the backhand-side might be related to the higher incidence of ACL injury during single-leg landing after overhead stroke.
Kiriyama, Shinya; Sato, Haruhiko; Takahira, Naonobu
2009-01-01
Increased shank rotation during landing has been considered to be one of the factors for noncontact anterior cruciate ligament injuries in female athletes. There have been no known gender differences in rotational knee muscle strength, which is expected to inhibit exaggerated shank rotation. Women have less knee external rotator strength than do men. Lower external rotator strength is associated with increased internal shank rotation at the time of landing. Controlled laboratory study. One hundred sixty-nine healthy young subjects (81 female and 88 male; age, 17.0 +/- 1.0 years) volunteered to participate in this study. The subjects performed single-legged drop landings from a 20-cm height. Femoral and shank kinematics were measured using a 3D optoelectronic tracking system during the drop landings, and then the joint angles around the knee (flexion/extension, valgus/varus, and internal/external rotation) were calculated. The maximal isometric rotational muscle strength of the knee was measured at 30 degrees of knee flexion in a supine position using a dynamometer. The female subjects had significantly less external shank rotation strength than did the male subjects (P < .001). Female subjects also exhibited significantly greater peak shank internal rotation angles than did males during landing (P < .05). Moderate but significant association was found between the maximum shank external rotation strength and the peak shank internal rotation angle during landing (r = -0.322, P < .01). Female subjects tended to have poor shank external rotator strength. This may lead to large shank internal rotation movement during the single-legged drop landing. Improving strength training of the external rotator muscle may help decrease the rates of anterior cruciate ligament injury in female athletes.
Witoolkollachit, Polawat; Seubchompoo, Onuma
2008-07-01
The tibial axis referencing method with a balanced tension flexion gap at 90 degrees knee flexion provides adequate femoral component rotation usually in external rotation, the trans-epicondylar line being parallel to the proximal tibial cut. The LCS mobile bearing TKA uses this technique to automatically determine the femoral component rotation with desired tension. The determination of the epicondyles may lead to some confusion. On the lateral side, the prominence of the lateral condyle makes it easy to define. However on the medial side, some surgeons use the prominent part of the medial epicondyle (well recognized on CT scan as the most proximal ridge that gives insertion to the superficial collateral ligament) and use the anatomical transepicondylar axis (aTEA). Other surgeons use the depression below called sulcus that defines the surgical transepicondylar axis (sTEA). The authors evaluated 40 clinically successful mobile bearing TKA in 33 patients. All the knees were performed by single surgeon and the rotational alignment of the femoral component was applied with balanced flexion gap technique. Post-op CT-scans were done in all knees with 2-mm interval and measurement of the different angles (between aTEA and the prosthetic posterior condylar line and between the sTEA and the prosthetic posterior condylar line) with the UTHSCSA Imagetool (IT) version 3 from the University of Texas Health Science Center at San Antonio. The authors found that the mean femoral implant angle was in 2.39 degrees (SD = 2.80) of internal rotation with reference to the aTEA and in 1.34 degrees (SD = 1.57 degrees) of external rotation with reference to the sTEA when the medial sulcus was perfectly detected (nine knees, 22.5%). The angle between the aTEA and the sTEA was -3.98 degrees (SD = 1.05 degrees). No patella subluxation was identified. Nineteen or 47.5% of the femoral components were in internal or external femoral rotation of more than 3 degrees to the aTEA. When sTEA was detected, no knee was in internal or external rotation more than 3 degrees to sTEA. The balanced flexion gap technique positions the femoral component in external rotation with the LCS TKA. Within 3 degrees to aTEA or sTEA, this technique produced femoral rotational angle closer to sTEA when the sulcus was detected and produced a wide range of different angles when compared to aTEA. However sTEA is not the consistent bony landmark. This technique is a reliable method to determine femoral rotational alignment.
Charlton, Jesse M; Hammond, Connor A; Cochrane, Christopher K; Hatfield, Gillian L; Hunt, Michael A
2017-06-01
Barbell back squats are a popular exercise for developing lower extremity strength and power. However, this exercise has potential injury risks, particularly to the lumbar spine, pelvis, and hip joint. Previous literature suggests heel wedges as a means of favorably adjusting trunk and pelvis kinematics with the intention of reducing such injury risks. Yet no direct biomechanical research exists to support these recommendations. Therefore, the purpose of this study was to examine the effects of heel wedges compared with barefoot on minimally loaded barbell back squats. Fourteen trained male participants performed a barbell back squat in bare feet or with their feet raised bilaterally with a 2.5-cm wooden block while 3-dimensional kinematics, kinetics, and electromyograms were collected. The heel wedge condition elicited significantly less forward trunk flexion angles at peak knee flexion, and peak external hip joint moments (p ≤ 0.05) compared with barefoot conditions. However, no significant differences were observed between conditions for trunk and pelvis angle differences at peak knee flexion (p > 0.05). Lastly, no peak or root mean square differences in muscle activity were elicited between conditions (p > 0.05). Our results lend support for the suggestions provided in literature aimed at using heel wedges as a means of reducing excessive forward trunk flexion. However, the maintenance of a neutral spine, another important safety factor, is not affected by the use of heel wedges. Therefore, heel wedges may be a viable modification for reduction of excessive forward trunk flexion but not for reduction in relative trunk-pelvis flexion during barbell back squats.
Mechanical behaviour of hamstring muscles in low-back pain patients and control subjects.
Tafazzoli, F; Lamontagne, M
1996-01-01
The purpose of this study was to measure and compare the passive elastic moment, the stiffness and the damping coefficient of the hip joint, as functions of the hip and knee joint angles in men with and without low-back pain. Two conventional tests, the straight-leg-raising test and the trunk forward flexion, were also performed and compared between these subjects. The passive elastic moment was measured using an isokinetic device in the passive mode. This device raised the lower limb from the horizontal position to the straight-leg-raising angle at a slow and constant angular velocity. A custom-made splint connected with the lever arm of the isokinetic device maintained the knee in extension and the ankle in the neutral position. The damping coefficient of the hip joint was measured for 0, 15, 45, 60, 75 and 90% of straight leg raising angle of each subject, using the suspension method based on small oscillation theory. To ensure that muscles were inactive during the passive hip moment tests, muscle activity was monitored with surface EMG. The stiffness was computed as the ratio of the change in passive elastic moment to the change in the hip angle. The passive elastic moment, the stiffness and the normalized trunk flexion were significantly different between the two groups respectively. There was, however, no difference between the two groups in the results of straight-leg-raise and damping coefficient of the hip. The passive elastic moment was a nonlinear function of the hip flexion angle and showed large intersubject differences, especially as the joint limit was approached. The damping coefficient was a polynomial function of the hip flexion angle. The measured variables were analysed using a discriminant function and it was shown that the two groups were clearly discriminable in a meaningful manner.
Markström, Jonas L; Tengman, Eva; Häger, Charlotte K
2018-02-01
Little is known regarding movement strategies in the long term following injury of the anterior cruciate ligament (ACL), and even less about comparisons of reconstructed and deficient knees in relation to healthy controls. The present purpose was to compare trunk, hip, and knee kinematics during a one-leg vertical hop (VH) ~20 years post-ACL injury between persons treated with surgery and physiotherapy (ACL R ), solely physiotherapy (ACL PT ), and controls (CTRL). Between-leg kinematic differences within groups were also investigated. Sixty-six persons who suffered unilateral ACL injury on average 23 ± 2 years ago (32 ACL R , 34 ACL PT ) and 33 controls performed the VH. Peak trunk, hip, and knee angles during Take-off and Landing phases recorded with a 3D motion capture system were analysed with multivariate statistics. Significant group effects during both Take-off and Landing were found, with ACL PT differing from CTRL in Take-off with a combination of less knee flexion and knee internal rotation, and from both ACL R and CTRL in Landing with less hip and knee flexion, knee internal rotation, and greater hip adduction. ACL R also presented different kinematics to ACL PT and CTRL in Take-off with a combination of greater trunk flexion, hip flexion, hip internal rotation, and less knee abduction, and in Landing with greater trunk flexion and hip internal rotation. Further, different kinematics and hop height were found between legs within groups in both Take-off and Landing for both ACL groups, but not for CTRL. Different kinematics for the injured leg for both ACL groups compared to CTRL and between treatment groups, as well as between legs within treatment groups, indicate long-term consequences of injury. Compensatory mechanisms for knee protection seem to prevail over time irrespective of initial treatment, possibly increasing the risk of re-injury and triggering the development of osteoarthritis. Detailed investigation of movement strategies during the VH provides important information and a more comprehensive evaluation of knee function than merely hop height. More attention should also be given to the trunk and hip in clinics when evaluating movement strategies after ACL injury. Prospective cohort study, Level II.
Wang, Joon Ho; Kato, Yuki; Ingham, Sheila J M; Maeyama, Akira; Linde-Rosen, Monica; Smolinski, Patrick; Fu, Freddie H
2012-10-01
The aim of this study was to determine the end-to-end distance changes in anterior cruciate ligament (ACL) fibers during flexion/extension and internal/external rotation of the knee. The positional relation between the femur and tibia of 10 knees was digitized on a robotic system during flexion/extension and with an internal/external rotational torque (5 Nm). The ACL insertion site data, acquired by 3-dimensional scanning, were superimposed on the positional data. The end-to-end distances of 5 representative points on the femoral and tibial insertion sites of the ACL were calculated. The end-to-end distances of all representative points except the most anterior points were longest at full extension and shortest at 90°. The distances of the anteromedial (AM) and posterolateral (PL) bundles were 37.2 ± 2.1 mm and 27.5 ± 2.8 mm, respectively, at full extension and 34.7 ± 2.4 mm and 20.7 ± 2.3 mm, respectively, at 90°. Only 4 knees had an isometric point, which was 1 of the 3 anterior points. Under an internal torque, both bundles became longer with statistical meaning at all flexion angles (P = .005). The end-to-end distances of all points became longest with internal torque at full extension and shortest with an external torque at 90°. Only 4 of 10 specimens had an isometric point at a variable anterior point. The end-to-end distances of the AM and PL bundles were longer in extension and shorter in flexion. The nonisometric tendency of the ACL and the end-to-end distance change during knee flexion/extension and internal/external rotation should be considered during ACL reconstruction to avoid overconstraint of the graft. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Gastrocnemius tightness on joint angle and work of lower extremity during gait.
You, Jia-Yuan; Lee, Hsin-Min; Luo, Hong-Ji; Leu, Chwan-Chin; Cheng, Pen-Gang; Wu, Shyi-Kuen
2009-11-01
Muscular tightness is a common clinical musculoskeletal disorder and is regarded as a predisposing factor for muscle injuries. In this study, a two-way mixed design ANOVA was applied to investigate the effects of the gastrocnemius tightness on the joint angle and joint work during walking. Twenty-two patients with muscular tightness of gastrocnemius muscle (<12 degrees of ankle dorsiflexion with knee extended) and 22 age- and gender-matched subjects with normal gastrocnemius flexibility (>15 degrees of ankle dorsiflexion with knee extended) participated in this study. The joint angle and work at hip, knee, and ankle joints during the stance phase were analyzed at two preset cadences of 100 steps/min and 140 steps/min. Significantly greater flexion angles at hip (P=0.025) and knee (P=0.001) were found in the tightness group at the time of maximal ankle dorsiflexion. Significantly less work generation at knee (P=0.034) and greater work absorption at ankle (P=0.024) were detected in the tightness group. The subjects with gastrocnemius tightness revealed a compensatory gait pattern, which included the changes in the joint angles and associated work productions. The potential disturbance of the knee control and strain injuries of plantar flexors might be crucial in the clinical considerations for subjects with gastrocnemius tightness.
Kerkum, Yvette L.; Buizer, Annemieke I.; van den Noort, Josien C.; Becher, Jules G.; Harlaar, Jaap; Brehm, Merel-Anne
2015-01-01
Introduction Rigid Ankle-Foot Orthoses (AFOs) are commonly prescribed to counteract excessive knee flexion during the stance phase of gait in children with cerebral palsy (CP). While rigid AFOs may normalize knee kinematics and kinetics effectively, it has the disadvantage of impeding push-off power. A spring-like AFO may enhance push-off power, which may come at the cost of reducing the knee flexion less effectively. Optimizing this trade-off between enhancing push-off power and normalizing knee flexion in stance is expected to maximize gait efficiency. This study investigated the effects of varying AFO stiffness on gait biomechanics and efficiency in children with CP who walk with excessive knee flexion in stance. Fifteen children with spastic CP (11 boys, 10±2 years) were prescribed with a ventral shell spring-hinged AFO (vAFO). The hinge was set into a rigid, or spring-like setting, using both a stiff and flexible performance. At baseline (i.e. shoes-only) and for each vAFO, a 3D-gait analysis and 6-minute walk test with breath-gas analysis were performed at comfortable speed. Lower limb joint kinematics and kinetics were calculated. From the 6-minute walk test, walking speed and the net energy cost were determined. A generalized estimation equation (p<0.05) was used to analyze the effects of different conditions. Compared to shoes-only, all vAFOs improved the knee angle and net moment similarly. Ankle power generation and work were preserved only by the spring-like vAFOs. All vAFOs decreased the net energy cost compared to shoes-only, but no differences were found between vAFOs, showing that the effects of spring-like vAFOs to promote push-off power did not lead to greater reductions in walking energy cost. These findings suggest that, in this specific group of children with spastic CP, the vAFO stiffness that maximizes gait efficiency is primarily determined by its effect on knee kinematics and kinetics rather than by its effect on push-off power. Trial Registration Dutch Trial Register NTR3418 PMID:26600039
Kerkum, Yvette L; Buizer, Annemieke I; van den Noort, Josien C; Becher, Jules G; Harlaar, Jaap; Brehm, Merel-Anne
2015-01-01
Rigid Ankle-Foot Orthoses (AFOs) are commonly prescribed to counteract excessive knee flexion during the stance phase of gait in children with cerebral palsy (CP). While rigid AFOs may normalize knee kinematics and kinetics effectively, it has the disadvantage of impeding push-off power. A spring-like AFO may enhance push-off power, which may come at the cost of reducing the knee flexion less effectively. Optimizing this trade-off between enhancing push-off power and normalizing knee flexion in stance is expected to maximize gait efficiency. This study investigated the effects of varying AFO stiffness on gait biomechanics and efficiency in children with CP who walk with excessive knee flexion in stance. Fifteen children with spastic CP (11 boys, 10±2 years) were prescribed with a ventral shell spring-hinged AFO (vAFO). The hinge was set into a rigid, or spring-like setting, using both a stiff and flexible performance. At baseline (i.e. shoes-only) and for each vAFO, a 3D-gait analysis and 6-minute walk test with breath-gas analysis were performed at comfortable speed. Lower limb joint kinematics and kinetics were calculated. From the 6-minute walk test, walking speed and the net energy cost were determined. A generalized estimation equation (p<0.05) was used to analyze the effects of different conditions. Compared to shoes-only, all vAFOs improved the knee angle and net moment similarly. Ankle power generation and work were preserved only by the spring-like vAFOs. All vAFOs decreased the net energy cost compared to shoes-only, but no differences were found between vAFOs, showing that the effects of spring-like vAFOs to promote push-off power did not lead to greater reductions in walking energy cost. These findings suggest that, in this specific group of children with spastic CP, the vAFO stiffness that maximizes gait efficiency is primarily determined by its effect on knee kinematics and kinetics rather than by its effect on push-off power. Dutch Trial Register NTR3418.
Jalali, Maryam; Farahmand, Farzam; Mousavi, Seyed Mohammad Ebrahim; Golestanha, Seyed Ali; Rezaeian, Tahmineh; Shirvani Broujeni, Shahram; Rahgozar, Mehdi; Esfandiarpour, Fateme
2015-07-01
Despite several studies with different methods, the effect of functional knee braces on knee joint kinematics is not clear. Direct visualization of joint components through medical imaging modalities may provide the clinicians with more useful information. In this study, for the first time in the literature, video fluoroscopy was used to investigate the effect of knee bracing on the sagittal plane kinematics of anterior cruciate ligament (ACL) injured patients. For twelve male unilateral ACL deficient subjects, the anterior tibial translation was measured during lunge exercise in non-braced and braced conditions. Fluoroscopic images were acquired from the subjects using a digital fluoroscopy system with a rate of 10 fps. The image of each frame was scaled using a calibration coin and analyzed in AutoCAD environment. The angle between the two lines, tangent to the posterior cortexes of the femoral and tibial shafts was measured as the flexion angle. For the fluoroscopic images associated with 0°, 15°, 30°, 45° and 60° knee flexion angles, the relative anterior-posterior configuration of the tibiofemoral joint was assessed by measuring the position of landmarks on the tibia and femur. Results indicated that the overall anterior translations of the tibia during the eccentric (down) and concentric (up) phases of lunge exercise were 10.4 ± 1.7 mm and 9.0 ± 2.2 mm for non-braced, and 10.1 ± 3.4 mm and 7.4 ± 2.5 mm, for braced conditions, respectively. The difference of the tibial anterior-posterior translation behaviors of the braced and non-braced knees was not statistically significant. Fluoroscopic imaging provides an effective tool to measure the dynamic behavior of the knee joint in the sagittal plane and within the limitations of this study, the pure mechanical stabilizing effect of functional knee bracing is not sufficient to control the anterior tibial translation of the ACL deficient patients during lunge exercise.
Kinematic Analysis of a Posterior-stabilized Knee Prosthesis
Zhao, Zhi-Xin; Wen, Liang; Qu, Tie-Bing; Hou, Li-Li; Xiang, Dong; Bin, Jia
2015-01-01
Background: The goal of total knee arthroplasty (TKA) is to restore knee kinematics. Knee prosthesis design plays a very important role in successful restoration. Here, kinematics models of normal and prosthetic knees were created and validated using previously published data. Methods: Computed tomography and magnetic resonance imaging scans of a healthy, anticorrosive female cadaver were used to establish a model of the entire lower limbs, including the femur, tibia, patella, fibula, distal femur cartilage, and medial and lateral menisci, as well as the anterior cruciate, posterior cruciate, medial collateral, and lateral collateral ligaments. The data from the three-dimensional models of the normal knee joint and a posterior-stabilized (PS) knee prosthesis were imported into finite element analysis software to create the final kinematic model of the TKA prosthesis, which was then validated by comparison with a previous study. The displacement of the medial/lateral femur and the internal rotation angle of the tibia were analyzed during 0–135° flexion. Results: Both the output data trends and the measured values derived from the normal knee's kinematics model were very close to the results reported in a previous in vivo study, suggesting that this model can be used for further analyses. The PS knee prosthesis underwent an abnormal forward displacement compared with the normal knee and has insufficient, or insufficiently aggressive, “rollback” compared with the lateral femur of the normal knee. In addition, a certain degree of reverse rotation occurs during flexion of the PS knee prosthesis. Conclusions: There were still several differences between the kinematics of the PS knee prosthesis and a normal knee, suggesting room for improving the design of the PS knee prosthesis. The abnormal kinematics during early flexion shows that the design of the articular surface played a vital role in improving the kinematics of the PS knee prosthesis. PMID:25591565
Panzica, Martin; Janzik, Janne; Bobrowitsch, Evgenij; Krettek, Christian; Hawi, Nael; Hurschler, Christof; Jagodzinski, Michael
2015-11-01
To date, various surgical techniques to treat posterolateral knee instability have been described. Recent studies recommended an anatomical and isometric reconstruction of the posterolateral corner addressing the key structures, such as lateral collateral ligament (LCL), popliteus tendon (POP) and popliteofibular ligament (PFL). Two clinical established autologous respective local reconstruction methods of the posterolateral complex were tested for knot-bone cylinder press-fit fixation to assess efficacy of each reconstruction technique in comparison to the intact knee. The knot-bone cylinder press-fit fixation for both anatomic and isometric reconstruction techniques of the posterolateral complex shows equal biomechanical stability as the intact posterolateral knee structures. This was a controlled laboratory study. Two surgical techniques (Larson: fibula-based semitendinosus autograft for LCL and PFL reconstruction/Kawano: biceps femoris and iliotibial tract autograft for LCL, PFL and POP reconstruction) with press-fit fixation were used for restoration of posterolateral knee stability. Seven cadaveric knees (66 ± 3.4 years) were tested under three conditions: intact knee, sectioned state and reconstructed knee for each surgical technique. Biomechanical stress tests were performed for every state at 30° and 90° knee flexion for anterior-posterior translation (60 N), internal-external and varus-valgus rotation (5 Nm) at 0°, 30° and 90° using a kinemator (Kuka robot). At 30° and 90° knee flexion, no significant differences between the four knee states were registered for anterior-posterior translation loading. Internal-external and varus-valgus rotational loading showed significantly higher instability for the sectioned state than for the intact or reconstructed posterolateral structures (p < 0.05). There were no significant differences between the intact and reconstructed knee states for internal-external rotation, varus-valgus rotation and anterior-posterior translation at any flexion angles (p > 0.05). Comparing both reconstruction techniques, significant higher varus-/valgus stability was registered for the fibula-based Larson technique at 90° knee flexion (p < 0.05). Both PLC reconstructions showed equal biomechanical stability as the intact posterolateral knee structures when using knot-bone cylinder press-fit fixation. We registered restoration of the rotational and varus-valgus stability with both surgical techniques. The anterior-posterior translational stability was not influenced significantly. The Larson technique showed significant higher varus/valgus stability in 90° flexion. The latter is easier to perform and takes half the preparation time, but needs grafting of the semitendinosus tendon. The Kawano reconstruction technique is an interesting alternative in cases of missing autografts.
Tibiofemoral Contact Forces in the Anterior Cruciate Ligament-Reconstructed Knee.
Saxby, David John; Bryant, Adam L; Modenese, Luca; Gerus, Pauline; Killen, Bryce A; Konrath, Jason; Fortin, Karine; Wrigley, Tim V; Bennell, Kim L; Cicuttini, Flavia M; Vertullo, Christopher; Feller, Julian A; Whitehead, Tim; Gallie, Price; Lloyd, David G
2016-11-01
To investigate differences in anterior cruciate ligament-reconstructed (ACLR) and healthy individuals in terms of the magnitude of the tibiofemoral contact forces, as well as the relative muscle and external load contributions to those contact forces, during walking, running, and sidestepping gait tasks. A computational EMG-driven neuromusculoskeletal model was used to estimate the muscle and tibiofemoral contact forces in those with single-bundle combined semitendinosus and gracilis tendon autograft ACLR (n = 104, 29.7 ± 6.5 yr, 78.1 ± 14.4 kg) and healthy controls (n = 60, 27.5 ± 5.4 yr, 67.8 ± 14.0 kg) during walking (1.4 ± 0.2 m·s), running (4.5 ± 0.5 m·s) and sidestepping (3.7 ± 0.6 m·s). Within the computational model, the semitendinosus of ACLR participants was adjusted to account for literature reported strength deficits and morphological changes subsequent to autograft harvesting. ACLR had smaller maximum total and medial tibiofemoral contact forces (~80% of control values, scaled to bodyweight) during the different gait tasks. Compared with controls, ACLR were found to have a smaller maximum knee flexion moment, which explained the smaller tibiofemoral contact forces. Similarly, compared with controls, ACLR had both a smaller maximum knee flexion angle and knee flexion excursion during running and sidestepping, which may have concentrated the articular contact forces to smaller areas within the tibiofemoral joint. Mean relative muscle and external load contributions to the tibiofemoral contact forces were not significantly different between ACLR and controls. ACLR had lower bodyweight-scaled tibiofemoral contact forces during walking, running, and sidestepping, likely due to lower knee flexion moments and straighter knee during the different gait tasks. The relative contributions of muscles and external loads to the contact forces were equivalent between groups.
Study of Wearable Knee Assistive Instruments for Walk Rehabilitation
NASA Astrophysics Data System (ADS)
Zhu, Yong; Nakamura, Masahiro; Ito, Noritaka; Fujimoto, Hiroshi; Horikuchi, Kenichi; Wakabayashi, Shojiro; Takahashi, Rei; Terada, Hidetsugu; Haro, Hirotaka
A wearable Knee Assistive Instrument for the walk rehabilitation was newly developed. Especially, this system aimed at supporting the rehabilitation for the post-TKA (Total Knee Arthroplasty) which is a popular surgery for aging people. This system consisted of an assisting mechanism for the knee joint, a hip joint support system and a foot pressure sensor system. The driving system of this robot consisted of a CPU board which generated the walking pattern, a Li-ion battery, DC motors with motor drivers, contact sensors to detect the state of foot and potentiometers to detect the hip joint angle. The control method was proposed to reproduce complex motion of knee joint as much as possible, and to increase hip or knee flexion angle. Especially, this method used the timing that heel left from the floor. This method included that the lower limb was raised to prevent a subject's fall. Also, the prototype of knee assisting system was tested. It was confirmed that the assisting system is useful.
Koh, Jason L; Yi, Seung Jin; Ren, Yupeng; Zimmerman, Todd A; Zhang, Li-Qun
2016-11-02
The meniscus is known to increase the contact area and decrease contact pressure in the tibiofemoral compartments of the knee. Radial tears of the meniscal root attachment along with partial resections of the torn meniscal tissue decrease the contact area and increase pressure; however, there is a lack of information on the effects of a horizontal cleavage tear (HCT) and partial leaf meniscectomy of such tears on tibiofemoral contact pressure and contact area. Twelve fresh-frozen human cadaveric knees were tested under 10 conditions: 5 serial conditions of posterior medial meniscectomy (intact meniscus, HCT, repaired HCT, inferior leaf resection, and resection of both inferior and superior leaves), each at 2 knee flexion angles (0° and 60°) under an 800-N axial load. Tekscan sensors (model 4000) were used to measure the contact pressure and contact area. HCT and HCT repair resulted in small changes in the contact area and an increase in contact pressure compared with the intact condition. Resection of the inferior leaf resulted in significantly decreased contact area (to a mean 82.3% of the intact condition at 0° of flexion and 81.8% at 60° of flexion; p < 0.05) and increased peak contact pressure (a mean 36.3% increase at 0° flexion and 43.2% increase at 60° flexion; p < 0.05) in the medial compartment. Further resection of the remaining superior leaf resulted in additional significant decreases in contact area (to a mean 60.1% of the intact condition at 0° of flexion and 49.7% at 60° of flexion; p < 0.05) and increases in peak contact pressure (a mean 79.2% increase at 0° of flexion and 74.9% increase at 60° of flexion; p < 0.05). Resection of meniscal tissue forming the inferior leaf of an HCT resulted in substantially decreased contact area and increased contact pressure. Additional resection of the superior leaf resulted in a further significant decrease in contact area and increase in contact pressure in the medial compartment. Repair or minimal resection of meniscal tissue of an HCT may be preferred to complete leaf resection to maintain knee tibiofemoral contact mechanics. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.
Hosseini, Ali; Qi, Wei; Tsai, Tsung-Yuan; Liu, Yujie; Rubash, Harry; Li, Guoan
2014-01-01
Purpose The knowledge of the function of the collateral ligaments – i.e., superficial medial collateral ligament (sMCL), deep medial collateral ligament (dMCL) and lateral collateral ligament (LCL) – in the entire range of knee flexion is important for soft tissue balance during total knee arthroplasty. The objective of this study was to investigate the length changes of different portions (anterior, middle and posterior) of the sMCL, dMCL and LCL during in vivo weightbearing flexion from full extension to maximal knee flexion. Methods Using a dual fluoroscopic imaging system eight healthy knees were imaged while performing a lunge from full extension to maximal flexion. The length changes of each portion of the collateral ligaments were measured along the flexion path of the knee. Results All anterior portions of the collateral ligaments were shown to have increasing length with flexion except that of the sMCL which showed a reduction in length at high flexion. The middle portions showed minimal change in lengths except that of the sMCL which showed a consistent reduction in length with flexion. All posterior portions showed reduction in lengths with flexion. Conclusions These data indicated that every portion of the ligaments may play important roles in knee stability at different knee flexion range. The soft tissue releasing during TKA may need to consider the function of the ligament portions along the entire flexion path including maximum flexion. PMID:25239504
Bennour, Sami; Ulrich, Baptiste; Legrand, Thomas; Jolles, Brigitte M; Favre, Julien
2018-01-03
Improving lower-limb flexion/extension angles during walking is important for the treatment of numerous pathologies. Currently, these gait retraining procedures are mostly qualitative, often based on visual assessment and oral instructions. This study aimed to propose an alternative method combining motion capture and display of target footprints on the floor. The second objectives were to determine the error in footprint modifications and the effects of footprint modifications on lower-limb flexion/extension angles. An augmented-reality system made of an optoelectronic motion capture device and video projectors displaying target footprints on the floor was designed. 10 young healthy subjects performed a series of 27 trials, consisting of increased and decreased amplitudes in stride length, step width and foot progression angle. 11 standard features were used to describe and compare lower-limb flexion/extension angles among footprint modifications. Subjects became accustomed to walk on target footprints in less than 10 min, with mean (± SD) precision of 0.020 ± 0.002 m in stride length, 0.022 ± 0.006 m in step width, and 2.7 ± 0.6° in progression angle. Modifying stride length had significant effects on 3/3 hip, 2/4 knee and 4/4 ankle features. Similarly, step width and progression angle modifications affected 2/3 and 1/3 hip, 2/4 and 1/4 knee as well as 3/4 and 2/4 ankle features, respectively. In conclusion, this study introduced an augmented-reality method allowing healthy subjects to modify their footprint parameters rapidly and precisely. Walking with modified footprints changed lower-limb sagittal-plane kinematics. Further research is needed to design rehabilitation protocols for specific pathologies. Copyright © 2017 Elsevier Ltd. All rights reserved.
Erhart-Hledik, Jennifer C; Asay, Jessica L; Clancy, Caitlin; Chu, Constance R; Andriacchi, Thomas P
2017-10-01
This study aimed to determine if active feedback gait retraining to produce a medial weight transfer at the foot significantly reduces the knee adduction moment in subjects with medial compartment knee osteoarthritis. Secondarily, changes in peak knee flexion moment, frontal plane knee and ankle kinematics, and center of pressure were investigated. Ten individuals with medial compartment knee osteoarthritis (9 males; age: 65.3 ± 9.8 years; BMI: 27.8 ± 3.0 kg/m 2 ) were tested at self-selected normal and fast speeds in two conditions: Intervention, with an active feedback device attached to the shoe of their more affected leg, and control, with the device de-activated. Kinematics and kinetics were assessed using a motion capture system and force plate. The first peak, second peak, and impulse of the knee adduction moment were significantly reduced by 6.0%, 13.9%, and 9.2%, respectively, at normal speed, with reductions of 10.7% and 8.6% in first peak and impulse at fast speed, respectively, with the active feedback system, with no significant effect on the peak knee flexion moment. Significant reductions in peak varus knee angle and medialized center of pressure in the first half of stance were observed, with reductions in peak varus knee angle associated with reductions in the knee adduction moment. This study demonstrated that active feedback to produce a medial weight-bearing shift at the foot reduces the peaks and impulse of the knee adduction moment in patients with medial compartment knee osteoarthritis. Future research should determine the long-term effect of the active feedback intervention on joint loading, pain, and function. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2251-2259, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Zhao, Chang; Lin, Chuangxin; Wang, Wenhao; Zeng, Chun; Fang, Hang; Pan, Jianying; Cai, Daozhang
2016-08-08
The purpose of this study was to measure the tibiofemoral kinematics of anterior cruciate ligament (ACL) deficiency in a Chinese population and compare the kinematics with published data about a Caucasian population. Unilateral knees of 18 Chinese ACL-deficient (ACL-D) subjects were studied while subjects ascended stairs. Kinematic alteration was compared between ACL-D knees and contralateral ACL-intact (ACL-I) knees. The kinematic alteration of ACL deficiency was also compared between the Chinese population and published data about a Caucasian population. A statistical difference was found in the three-dimensional rotations between ACL-D and ACL-I knees. In the sagittal plane, ACL-I knees had a larger flexion angle than ACL-D knees during 40 to 50 % of the activity during stair ascent (P < 0.027) and throughout the gait cycle. A significant difference in rotational motion between ACL-D and ACL-I knees was also observed in the frontal plane during 40 to 60 % (P < 0.017) of the activity and in the transverse plane during 70 to 80 % (P < 0.028) of the activity. A greater tibial varus was demonstrated in the Chinese population while the published data revealed external tibial rotation and a statistical difference in translation in the Caucasian population. ACL-D knees show different kinematics than ACL-I knees in the Chinese population. ACL-I knees had a larger flexion angle than ACL-D knees in the middle stage of the activity during stair ascent. A significant difference in rotational motion between ACL-D and ACL-I knees was also observed in the frontal plane during the middle phase and in the transverse plane during the terminal phase of the activity. A greater tibial varus was demonstrated in the Caucasian population while the published data revealed external tibial rotation and a statistical difference in translation in the Caucasian population.
Naili, Josefine E; Wretenberg, Per; Lindgren, Viktor; Iversen, Maura D; Hedström, Margareta; Broström, Eva W
2017-03-21
It is not well understood why one in five patients report poor outcomes following knee arthroplasty. This study evaluated changes in knee biomechanics, and perceived pain among patients reporting either a good or a poor outcome in knee-related quality of life after total knee arthroplasty. Twenty-eight patients (mean age 66 (SD 7) years) were included in this prospective study. Within one month of knee arthroplasty and one year after surgery, patients underwent three-dimensional (3D) gait analysis, completed the Knee Injury and Osteoarthritis Outcome Score (KOOS), and rated perceived pain using a visual analogue scale. A "good outcome" was defined as a change greater than the minimally detectable change in the KOOS knee-related quality of life, and a "poor outcome" was defined as change below the minimally detectable change. Nineteen patients (68%) were classified as having a good outcome. Groups were analyzed separately and knee biomechanics were compared using a two-way repeated measures ANOVA. Differences in pain between groups were evaluated using Mann Whitney U test. Patients classified as having a good outcome improved significantly in most knee gait biomechanical outcomes including increased knee flexion-extension range, reduced peak varus angle, increased peak flexion moment, and reduced peak valgus moment. The good outcome group also displayed a significant increase in walking speed, a reduction (normalization) of stance phase duration (% of gait cycle) and increased passive knee extension. Whereas, the only change in knee biomechanics, one year after surgery, for patients classified as having a poor outcome was a significant reduction in peak varus angle. No differences in pain postoperatively were found between groups. Patients reporting a good outcome in knee-related quality of life improved in knee biomechanics during gait, while patients reporting a poor outcome, despite similar reduction in pain, remained unchanged in knee biomechanics one year after total knee arthroplasty. With regards to surgeon-controlled biomechanical factors, surgery may most successfully address frontal plane knee alignment. However, achieving a good outcome in patient-reported knee-related quality of life may be related to dynamic improvements in the sagittal plane.
Tran, Andrew A; Gatewood, Corey; Harris, Alex H S; Thompson, Julie A; Dragoo, Jason L
2016-12-01
Identification of biomechanical risk factors associated with anterior cruciate ligament (ACL) injury can facilitate injury prevention. The purpose of this study is to investigate the effects of three foot landing positions, "toe-in", "toe-out" and "neutral", on biomechanical risk factors for ACL injury in males and females. The authors hypothesize that 1) relative to neutral, the toe-in position increases the biomechanical risk factors for ACL injury, 2) the toe-out position decreases these biomechanical risk factors, and 3) compared to males, females demonstrate greater changes in lower extremity biomechanics with changes in foot landing position. Motion capture data on ten male and ten female volunteers aged 20-30 years (26.4 ± 2.50) were collected during double-leg jump landing activities. Subjects were asked to land on force plates and target one of three pre-templated foot landing positions: 0° ("neutral"), 30° internal rotation ("toe-in"), and 30° external rotation ("toe-out") along the axis of the anatomical sagittal plane. A mixed-effects ANOVA and pairwise Tukey post-hoc comparison were used to detect differences in kinematic and kinetic variables associated with biomechanical risk factors of ACL injury between the three foot landing positions. Relative to neutral, landing in the toe-in position increased peak hip adduction, knee internal rotation angles and moments (p < 0.01), and peak knee abduction angle (p < 0.001). Landing in the toe-in position also decreased peak hip flexion angle (p < 0.001) and knee flexion angle (p = 0.023). Landing in the toe-out position decreased peak hip adduction, knee abduction, and knee internal rotation angles (all p < 0.001). Male sex was associated with a smaller increase in hip adduction moment (p = 0.043) and knee internal rotation moment (p = 0.032) with toe-in landing position compared with female sex. Toe-in landing position exacerbates biomechanical risk factors associated with ACL injury, while toe-out landing position decreases these factors.
Hip-Extensor Strength, Trunk Posture, and Use of the Knee-Extensor Muscles During Running.
Teng, Hsiang-Ling; Powers, Christopher M
2016-07-01
Diminished hip-muscle performance has been proposed to contribute to various knee injuries. To determine the association between hip-extensor muscle strength and sagittal-plane trunk posture and the relationships among hip-extensor muscle strength and hip- and knee-extensor work during running. Descriptive laboratory study. Musculoskeletal biomechanical laboratory. A total of 40 asymptomatic recreational runners, 20 men (age = 27.1 ± 7.0 years, height = 1.74 ± 0.69 m, mass = 71.1 ± 8.2 kg) and 20 women (age = 26.2 ± 5.8 years, height = 1.65 ± 0.74 m, mass = 60.6 ± 6.6 kg), participated. Maximum isometric strength of the hip extensors was assessed using a dynamometer. Sagittal-plane trunk posture (calculated relative to the global vertical axis) and hip- and knee-extensor work (sum of energy absorption and generation) during the stance phase of running were quantified while participants ran over ground at a controlled speed of 3.4 m/s. We used Pearson product moment correlations to examine the relationships among hip-extensor strength, mean sagittal-plane trunk-flexion angle, hip-extensor work, and knee-extensor work. Hip-extensor strength was correlated positively with trunk-flexion angle (r = 0.55, P < .001) and hip-extensor work (r = 0.46, P = .003). It was correlated inversely with knee-extensor work (r = -0.39, P = .01). All the correlations remained after adjusting for sex. Our findings suggest that runners with hip-extensor weakness used a more upright trunk posture. This strategy led to an overreliance on the knee extensors and may contribute to overuse running injuries at the knee.
Hip-Extensor Strength, Trunk Posture, and Use of the Knee-Extensor Muscles During Running
Teng, Hsiang-Ling; Powers, Christopher M.
2016-01-01
Context: Diminished hip-muscle performance has been proposed to contribute to various knee injuries. Objective: To determine the association between hip-extensor muscle strength and sagittal-plane trunk posture and the relationships among hip-extensor muscle strength and hip- and knee-extensor work during running. Design: Descriptive laboratory study. Setting: Musculoskeletal biomechanical laboratory. Patients or Other Participants: A total of 40 asymptomatic recreational runners, 20 men (age = 27.1 ± 7.0 years, height = 1.74 ± 0.69 m, mass = 71.1 ± 8.2 kg) and 20 women (age = 26.2 ± 5.8 years, height = 1.65 ± 0.74 m, mass = 60.6 ± 6.6 kg), participated. Main Outcome Measure(s): Maximum isometric strength of the hip extensors was assessed using a dynamometer. Sagittal-plane trunk posture (calculated relative to the global vertical axis) and hip- and knee-extensor work (sum of energy absorption and generation) during the stance phase of running were quantified while participants ran over ground at a controlled speed of 3.4 m/s. We used Pearson product moment correlations to examine the relationships among hip-extensor strength, mean sagittal-plane trunk-flexion angle, hip-extensor work, and knee-extensor work. Results: Hip-extensor strength was correlated positively with trunk-flexion angle (r = 0.55, P < .001) and hip-extensor work (r = 0.46, P = .003). It was correlated inversely with knee-extensor work (r = −0.39, P = .01). All the correlations remained after adjusting for sex. Conclusions: Our findings suggest that runners with hip-extensor weakness used a more upright trunk posture. This strategy led to an overreliance on the knee extensors and may contribute to overuse running injuries at the knee. PMID:27513169
Inoue, Hiroto; Furumatsu, Takayuki; Miyazawa, Shinichi; Fujii, Masataka; Kodama, Yuya; Ozaki, Toshifumi
2018-02-01
Anterior cruciate ligament (ACL) reconstruction can reduce the risk of developing osteoarthritic knees. The goals of ACL reconstruction are to restore knee stability and reduce post-traumatic meniscal tears and cartilage degradation. A chronic ACL insufficiency frequently results in medial meniscus (MM) injury at the posterior segment. How ACL reconstruction can reduce the deformation of the MM posterior segment remains unclear. In this study, we evaluated the form of the MM posterior segment and anterior tibial translation before and after ACL reconstruction using open magnetic resonance imaging (MRI). Seventeen patients who underwent ACL reconstructions without MM injuries were included in this study. MM deformation was evaluated using open MRI before surgery and 3 months after surgery. We measured medial meniscal length (MML), medial meniscal height (MMH), medial meniscal posterior body width (MPBW), MM-femoral condyle contact width (M-FCW) and posterior tibiofemoral distance (PTFD) at knee flexion angles of 10° and 90°. There were no significant pre- and postoperative differences during a flexion angle of 10°. At a flexion angle of 90°, MML decreased from 43.7 ± 4.5 to 41.4 ± 4.5 mm (P < 0.001), MMH from 7.5 ± 1.4 to 6.9 ± 1.4 mm (P = 0.006), MPBW from 13.1 ± 2.0 to 12.2 ± 1.9 mm (P < 0.001) and M-FCW from 10.0 ± 1.5 to 8.5 ± 1.5 mm (P < 0.001) after ACL reconstruction. The PTFD increased from 2.1 ± 2.8 to 2.7 ± 2.4 mm after ACL reconstruction (P = 0.015). ACL reconstruction affects the contact pattern between the MM posterior segment and medial femoral condyle and can reduce the deformation of the MM posterior segment in the knee-flexed position by reducing abnormal anterior tibial translation. It possibly prevents secondary injury to the MM posterior segment and cartilage that progresses to knee osteoarthritis. IV.
Ruan, Jesse S; El-Jawahri, Raed; Barbat, Saeed; Rouhana, Stephen W; Prasad, Priya
2008-11-01
Changes in vehicle safety design technology and the increasing use of seat-belts and airbag restraint systems have gradually changed the relative proportion of lower extremity injuries. These changes in real world injuries have renewed interest and the need of further investigation into occupant injury mechanisms and biomechanical impact responses of the knee-thigh-hip complex during frontal impacts. This study uses a detailed finite element model of the human body to simulate occupant knee impacts experienced in frontal crashes. The human body model includes detailed anatomical features of the head, neck, shoulder, chest, thoracic and lumbar spine, abdomen, pelvis, and lower and upper extremities. The material properties used in the model for each anatomic part of the human body were obtained from test data reported in the literature. The human body model used in the current study has been previously validated in frontal and side impacts. It was further validated with cadaver knee-thigh-hip impact tests in the current study. The effects of impactor configuration and flexion angle of the knee on biomechanical impact responses of the knee-thigh-hip complex were studied using the validated human body finite element model. This study showed that the knee flexion angle and the impact direction and shape of the impactors affected the injury outcomes of the knee-thigh-hip complex significantly. The 60 degrees flexed knee impact showed the least impact force, knee pressure, femoral von Mises stress, and pelvic von Mises stress but largest relative displacements of the Posterior Cruciate Ligament (PCL) and Anterior Cruciate Ligament (ACL). The 90 degrees flexed knee impact resulted in a higher impact force, knee pressure, femoral von Mises stress, and pelvic von Mises stress; but smaller PCL and ACL displacements. Stress distributions of the patella, femur, and pelvis were also given for all the simulated conditions.
Predictors of proximal tibia anterior shear force during a vertical stop-jump.
Sell, Timothy C; Ferris, Cheryl M; Abt, John P; Tsai, Yung-Shen; Myers, Joseph B; Fu, Freddie H; Lephart, Scott M
2007-12-01
Anterior cruciate ligament (ACL) continues to be a significant medical issue for athletes participating in sports and recreational activities. Biomechanical analyses have determined that anterior shear force is the most direct loading mechanism of the ACL and a probable component of noncontact ACL injury. The purpose of this study was to examine the biomechanical predictors of proximal tibia anterior shear force during a stop-jump task. A biomechanical and electromyographic (EMG) analysis of the knee was conducted while subjects performed a vertical stop-jump task. The task was chosen to simulate an athletic maneuver that included a landing with a sharp deceleration and a change in direction. The final regression model indicated that posterior ground reaction force, external knee flexion moment, knee flexion angle, integrated EMG activity of the vastus lateralis, and sex (female) would significantly predict proximal tibia anterior shear force (p < 0.0001, R2 = 0.8609). Knee flexion moment had the greatest influence on proximal tibia anterior shear force. The mathematical relationships elucidated in the current study support previous clinical and basic science research examining noncontact ACL injuries. This data provides important evidence for clinicians who are examining the risk factors for these injuries and developing/validating training programs to reduce the incidence of injury. Copyright 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Orishimo, Karl F; McHugh, Malachy P
2015-03-01
The purposes of this study were to document relative activation intensities of the hamstrings and gluteus maximus during 4 eccentric hamstring strengthening exercises and to assess the effects of a short-term strengthening program comprised of these exercises on knee flexor strength and the length-tension relationship. Twelve healthy subjects participated in this study. Electromyographic (EMG) activities from the biceps femoris, semitendinosus, and gluteus maximus were recorded as subjects performed (a) standing hip extension with elastic resistance, (b) trunk flexion in single limb stance (diver), (c) standing split (glider), and (d) supine sliding bridge (slider). Baseline isometric knee flexor strength was measured at 90, 70, 50, and 30° of flexion at the knee with the subject seated and the hip flexed to 50° from horizontal. After completing the 4-week training program, strength tests were repeated. Repeated-measures analysis of variance were used to compare EMG activity between muscles and to assess angle-specific strength improvements. Hamstring activity exceeded gluteus maximus activity for resisted hip extension, glider, and slider exercises (p < 0.001) but not for the diver (p = 0.087). Hamstring activation was greatest during the slider and resisted hip extension and lowest during the glider and the diver. Knee flexor strength improved by 9.0% (p = 0.005) but was not angle specific (training by angle p = 0.874). The short-term home training program effectively targeted the hamstrings and resulted in strength gains that were similar at short and long muscle lengths. These data demonstrate that hamstring strength can be improved using eccentrically biased unilateral exercises without the use of weights or other equipments.
Analysis of the lateral push-off in the freestyle flip turn.
Araujo, Luciana; Pereira, Suzana; Gatti, Roberta; Freitas, Elinai; Jacomel, Gabriel; Roesler, Helio; Villas-Boas, Joao
2010-09-01
The aim of this study was to examine the contact phase during the lateral push-off in the turn of front crawl swimming to determine which biomechanical variables (maximum normalized peak force, contact time, impulse, angle of knee flexion, and total turn time within 15 m) contribute to the performance of this turn technique. Thirty-four swimmers of state, national, and international competitive standard participated in the study. For data collection, the following equipment was used: an underwater force platform, a 30-Hz VHS video camera, and a MiniDv digital camera within an underwater box. Data are expressed as descriptive statistics. Inferential analyses were performed using Pearson's correlation and multiple linear regressions. All variables studied had a significant relationship with turn performance. We conclude that a turn executed with a knee flexion angle of between 100° and 120° provides optimum peak forces to generate impulses that allow the swimmer to lose less time in the turn without the need for an excessive force application and with less energy lost.
Ko, Dae-Sik; Jung, Dae-In; Jeong, Mi-Ae
2014-11-01
[Purpose] The aim of the present study was to investigate the effects of core stability exercise (CSE) on the physical and psychological functions of elderly women while negotiating general obstacles. [Subjects and Methods] After allocating 10 elderly women each to the core stability training group and the control group, we carried out Performance-Oriented Mobility Assessment (POMA) and measured crossing velocity (CV), maximum vertical heel clearance (MVHC), and knee flexion angle for assessing physical performances. We evaluated depression and fear of falling for assessing psychological functions. [Results] Relative to the control group, the core stability training group showed statistically significant overall changes after the training session: an increase in POMA scores, faster CV, lower MVHC, and a decrease in knee flexion angle. Furthermore, depression and fear of falling decreased significantly. [Conclusion] CSE can have a positive effect on the improvement of physical and psychological performances of older women who are vulnerable to falls as they negotiate everyday obstacles.
The effect of minimalist footwear and instruction on running: an observational study.
Barcellona, Massimo Giuseppe; Buckley, Linda; Palmer, Lisa J M; Ormond, Roisin M; Owen, Gwawr; Watson, Daniel J; Woledge, Roger; Newham, Di
2017-01-01
It is not known whether the effects on altered running style which are attributed to minimalist footwear can be achieved by verbal instructions in standard running shoes (SRS). To explore the effect of Vibram FiveFingers (VFF) versus SRS plus running instruction on lower extremity spatiotemporal parameters and lower limb joint kinematics. 35 healthy subjects (mean=30 years, 18 females) were assessed on two occasions with 3D motion analysis. At each session subjects ran on a treadmill (3.58 m/s) for 2 min in either VFF or SRS (randomised order); with and without running instruction. Differences between spatiotemporal parameters and lower limb joint kinematics between conditions were assessed using a 2x2 repeated-measures ANOVA. Wearing VFF significantly increased cadence (p<0.001) and reduced stride length (p<0.01). Prior to initial contact, both instruction and VFF significantly increased foot (p<0.001 and p=0.02, respectively) and ankle (p<0.001 and p=0.02, respectively) plantarflexion, while wearing VFF significantly increased knee extension (p=0.04). At initial contact, instruction significantly increased knee flexion (p=0.04), and foot (p=0.001) and ankle (p=0.03) plantarflexion. At mid-stance and toe-off, instruction significantly increased knee flexion (p=0.048 and p<0.001, respectively) and foot plantarflexion (p<0.001 and p=0.01, respectively). Instruction had a greater effect on increasing knee flexion (p=0.007) and plantarflexion angle (p<0.001) when subjects wore SRS and VFF, respectively. Alterations in spatiotemporal parameters observed when running in VFF are likely to be attributable to the minimalist footwear. However, the kinematic adaptations observed following instruction suggests that changes in joint angles previously attributed to minimalist footwear alone may be similarly achieved with instruction.
Dreher, Thomas; Wolf, Sebastian I; Maier, Michael; Hagmann, Sébastien; Vegvari, Dóra; Gantz, Simone; Heitzmann, Daniel; Wenz, Wolfram; Braatz, Frank
2012-10-03
The evidence for distal rectus femoris transfer as a part of multilevel surgery for the correction of stiff-knee gait in children with spastic diplegic cerebral palsy is limited because of inconsistent outcomes reported in various studies and the lack of long-term evaluations. This study investigated the long-term results (mean, nine years) for fifty-three ambulatory patients with spastic diplegic cerebral palsy and stiff-knee gait treated with standardized distal rectus femoris transfer as a part of multilevel surgery. Standardized three-dimensional gait analysis and clinical examination were carried out before surgery and at one year and nine years after surgery. Patients with decreased peak knee flexion in swing phase who had distal rectus femoris transfer to correct the decreased peak knee flexion in swing phase (C-DRFT) were evaluated separately from those with normal or increased peak knee flexion in swing phase who had distal rectus femoris transfer done as a prophylactic procedure (P-DRFT). A significantly increased peak knee flexion in swing phase was found in the C-DRFT group one year after surgery, while a significant loss (15°) in peak knee flexion in swing phase was noted in the P-DRFT group. A slight but not significant increase in peak knee flexion in swing phase in both groups was noted at the time of the long-term follow-up. A significant improvement in timing of peak knee flexion in swing phase was only found for the C-DRFT group, and was maintained after nine years. Knee motion and knee flexion velocity were significantly increased in both groups and were maintained at long-term follow-up in the C-DRFT group, while the P-DRFT showed a deterioration of knee motion. Distal rectus femoris transfer is an effective procedure to treat stiff-knee gait featuring decreased peak knee flexion in swing phase and leads to a long-lasting increase of peak knee flexion in swing phase nine years after surgery. Patients with more involvement showed a greater potential to benefit from distal rectus femoris transfer. However, 18% of the patients showed a permanently poor response and 15% developed recurrence. In patients with severe knee flexion who underwent a prophylactic distal rectus femoris transfer, a significant loss in peak knee flexion in swing phase was noted and thus a prophylactic distal rectus femoris transfer may not be indicated in these patients. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Fujimaki, Yoshimasa; Thorhauer, Eric; Sasaki, Yusuke; Smolinski, Patrick; Tashman, Scott; Fu, Freddie H
2016-01-01
Quantification of the cross-sectional area (CSA) of the anterior cruciate ligament (ACL) in different loading conditions is important for understanding the native anatomy and thus achieving anatomic reconstruction. The ACL insertion sites are larger than the ACL midsubstance, and the isthmus (region of the smallest CSA) location may vary with the load or flexion angle. To (1) quantify the CSA along the entire ACL, (2) describe the location of the ACL isthmus, (3) explore the relationship between ACL length and CSA, and (4) validate magnetic resonance imaging (MRI) for assessing the CSA of the midsubstance ACL. Descriptive laboratory study. Eight cadaveric knees were dissected to expose the ACL and its attachments. Knees were positioned using a robotic loading system through a range of flexion angles in 3 loading states: (1) unloaded, (2) anterior tibial translation, and (3) combined rotational load of valgus and internal torque. Laser scanning quantified the shape of the ACL and its insertion site boundaries. The CSA of the ACL was measured, and the location of the isthmus was determined; the CSA of the ACL was also estimated from MRI and compared with the laser-scanned data. The CSA of the ACL varied along the ligament, and the isthmus existed at an average (±SD) of 53.8% ± 5.5% of the distance from the tibial insertion center to the femoral insertion center. The average CSA at the isthmus was smallest in extension (39.9 ± 13.7 mm(2)) and increased with flexion (43.9 ± 12.1 mm(2) at 90°). The ACL length was shortest at 90° of flexion and increased by 18.8% ± 10.1% in unloaded extension. Application of an anterior load increased the ACL length by 5.0% ± 3.3% in extension, and application of a combined rotational load increased its length by 4.1% ± 3.0% in extension. The ACL isthmus is located almost half of the distance between the insertion sites. The CSA of the ACL at the isthmus is largest with the knee unloaded and at 90° of flexion, and the area decreases with extension and applied loads. The CSA at the isthmus represents less than half the area of the insertion sites. These results may aid surgical planning, specifically for choosing a graft size and fixation angle that most closely matches the native anatomy and function across the entire range of knee motion. © 2015 The Author(s).
Damiano, Diane L.; Bulea, Thomas C.
2016-01-01
Individuals with cerebral palsy frequently exhibit crouch gait, a pathological walking pattern characterized by excessive knee flexion. Knowledge of the knee joint moment during crouch gait is necessary for the design and control of assistive devices used for treatment. Our goal was to 1) develop statistical models to estimate knee joint moment extrema and dynamic stiffness during crouch gait, and 2) use the models to estimate the instantaneous joint moment during weight-acceptance. We retrospectively computed knee moments from 10 children with crouch gait and used stepwise linear regression to develop statistical models describing the knee moment features. The models explained at least 90% of the response value variability: peak moment in early (99%) and late (90%) stance, and dynamic stiffness of weight-acceptance flexion (94%) and extension (98%). We estimated knee extensor moment profiles from the predicted dynamic stiffness and instantaneous knee angle. This approach captured the timing and shape of the computed moment (root-mean-squared error: 2.64 Nm); including the predicted early-stance peak moment as a correction factor improved model performance (root-mean-squared error: 1.37 Nm). Our strategy provides a practical, accurate method to estimate the knee moment during crouch gait, and could be used for real-time, adaptive control of robotic orthoses. PMID:27101612
Moewis, P; Boeth, H; Heller, M O; Yntema, C; Jung, T; Doyscher, R; Ehrig, R M; Zhong, Y; Taylor, W R
2014-07-01
The in vivo quantification of rotational laxity of the knee joint is of importance for monitoring changes in joint stability or the outcome of therapies. While invasive assessments have been used to study rotational laxity, non-invasive methods are attractive particularly for assessing young cohorts. This study aimed to determine the conditions under which tibio-femoral rotational laxity can be assessed reliably and accurately in a non-invasive manner. The reliability and error of non-invasive examinations of rotational joint laxity were determined by comparing the artefact associated with surface mounted markers against simultaneous measurements using fluoroscopy in five knees including healthy and ACL deficient joints. The knees were examined at 0°, 30°, 60° and 90° flexion using a device that allows manual axial rotation of the joint. With a mean RMS error of 9.6°, the largest inaccuracy using non-invasive assessment was present at 0° knee flexion, whereas at 90° knee flexion, a smaller RMS error of 5.7° was found. A Bland and Altman assessment indicated that a proportional bias exists between the non-invasive and fluoroscopic approaches, with limits of agreement that exceeded 20°. Correction using average linear regression functions resulted in a reduction of the RMS error to below 1° and limits of agreement to less than ±1° across all knees and flexion angles. Given the excellent reliability and the fact that a correction of the surface mounted marker based rotation values can be achieved, non-invasive evaluation of tibio-femoral rotation could offer opportunities for simplified devices for use in clinical settings in cases where invasive assessments are not justified. Although surface mounted marker based measurements tend to overestimate joint rotation, and therefore joint laxity, our results indicate that it is possible to correct for this error. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.
Contributions of muscles and passive dynamics to swing initiation over a range of walking speeds.
Fox, Melanie D; Delp, Scott L
2010-05-28
Stiff-knee gait is a common walking problem in cerebral palsy characterized by insufficient knee flexion during swing. To identify factors that may limit knee flexion in swing, it is necessary to understand how unimpaired subjects successfully coordinate muscles and passive dynamics (gravity and velocity-related forces) to accelerate the knee into flexion during double support, a critical phase just prior to swing that establishes the conditions for achieving sufficient knee flexion during swing. It is also necessary to understand how contributions to swing initiation change with walking speed, since patients with stiff-knee gait often walk slowly. We analyzed muscle-driven dynamic simulations of eight unimpaired subjects walking at four speeds to quantify the contributions of muscles, gravity, and velocity-related forces (i.e. Coriolis and centrifugal forces) to preswing knee flexion acceleration during double support at each speed. Analysis of the simulations revealed contributions from muscles and passive dynamics varied systematically with walking speed. Preswing knee flexion acceleration was achieved primarily by hip flexor muscles on the preswing leg with assistance from biceps femoris short head. Hip flexors on the preswing leg were primarily responsible for the increase in preswing knee flexion acceleration during double support with faster walking speed. The hip extensors and abductors on the contralateral leg and velocity-related forces opposed preswing knee flexion acceleration during double support. Copyright 2010 Elsevier Ltd. All rights reserved.
Contributions of muscles and passive dynamics to swing initiation over a range of walking speeds
Fox, Melanie D.; Delp, Scott L.
2010-01-01
Stiff-knee gait is a common walking problem in cerebral palsy characterized by insufficient knee flexion during swing. To identify factors that may limit knee flexion in swing, it is necessary to understand how unimpaired subjects successfully coordinate muscles and passive dynamics (gravity and velocity-related forces) to accelerate the knee into flexion during double support, a critical phase just prior to swing that establishes the conditions for achieving sufficient knee flexion during swing. It is also necessary to understand how contributions to swing initiation change with walking speed, since patients with stiff-knee gait often walk slowly. We analyzed muscle-driven dynamic simulations of eight unimpaired subjects walking at four speeds to quantify the contributions of muscles, gravity, and velocity-related forces (i.e. Coriolis and centrifugal forces) to preswing knee flexion acceleration during double support at each speed. Analysis of the simulations revealed contributions from muscles and passive dynamics varied systematically with walking speed. Preswing knee flexion acceleration was achieved primarily by hip flexor muscles on the preswing leg with assistance from biceps femoris short head. Hip flexors on the preswing leg were primarily responsible for the increase in preswing knee flexion acceleration during double support with faster walking speed. The hip extensors and abductors on the contralateral leg and velocity-related forces opposed preswing knee flexion acceleration during double support. PMID:20236644
Jakobsen, Markus Due; Sundstrup, Emil; Andersen, Christoffer H; Bandholm, Thomas; Thorborg, Kristian; Zebis, Mette K; Andersen, Lars L
2012-12-01
While elastic resistance training, targeting the upper body is effective for strength training, the effect of elastic resistance training on lower body muscle activity remains questionable. The purpose of this study was to evaluate the EMG-angle relationship of the quadriceps muscle during 10-RM knee-extensions performed with elastic tubing and an isotonic strength training machine. 7 women and 9 men aged 28-67 years (mean age 44 and 41 years, respectively) participated. Electromyographic (EMG) activity was recorded in 10 muscles during the concentric and eccentric contraction phase of a knee extension exercise performed with elastic tubing and in training machine and normalized to maximal voluntary isometric contraction (MVC) EMG (nEMG). Knee joint angle was measured during the exercises using electronic inclinometers (range of motion 0-90°). When comparing the machine and elastic resistance exercises there were no significant differences in peak EMG of the rectus femoris (RF), vastus lateralis (VL), vastus medialis (VM) during the concentric contraction phase. However, during the eccentric phase, peak EMG was significantly higher (p<0.01) in RF and VM when performing knee extensions using the training machine. In VL and VM the EMG-angle pattern was different between the two training modalities (significant angle by exercise interaction). When using elastic resistance, the EMG-angle pattern peaked towards full knee extension (0°), whereas angle at peak EMG occurred closer to knee flexion position (90°) during the machine exercise. Perceived loading (Borg CR10) was similar during knee extensions performed with elastic tubing (5.7±0.6) compared with knee extensions performed in training machine (5.9±0.5). Knee extensions performed with elastic tubing induces similar high (>70% nEMG) quadriceps muscle activity during the concentric contraction phase, but slightly lower during the eccentric contraction phase, as knee extensions performed using an isotonic training machine. During the concentric contraction phase the two different conditions displayed reciprocal EMG-angle patterns during the range of motion. 5.
Echegoyen, Soledad; Aoyama, Takeshi; Rodríguez, Cristina
2013-06-01
Zapateado is a repetitive percussive footwork in dance. This percussive movement, and the differences in technique, may be risk factors for injury. A survey on zapateado dance students found a rate of 1.5 injuries/1,000 exposures. Knee injuries are more frequent than in Spanish dancers than folkloric dancers. The aim of this research was to study the relationship between technique and ground reaction force between zapateado on Spanish and Mexican folkloric dancers. Ten female dance students (age 22.4 ± 4 yrs), six Spanish dancers and four Mexican folkloric dancers, were considered. Each student performed zapateado with a flat foot, wearing high-heeled shoes during 5 seconds on a force platform. Videotapes were taken on a lateral plane, and knee and hip angles in each movement phase were measured with Dartfish software. Additionally, knee and ankle flexor and extensor strength was measured with a dynamometer. Ground reaction forces were lower for Spanish dancers than Mexican folkloric dancers. Spanish dancers had less knee flexion when the foot contacted to the ground than did Mexican folkloric dancers. On Spanish dancers, the working leg had more motion in relation to hip and knee angles than was seen in folkloric dancers. The ankle extensors were stronger on folkloric dancers, and there were no differences for the other muscle groups. Knee flexion at foot contact and muscle strength imbalance could be risk factors for injuries. It is suggested that the technique in Spanish dance in Mexico be reviewed, although more studies are required to define more risk factors.
Williams, D S Blaise; Welch, Lee M
2015-01-01
Injuries to runners are common. However, there are many potential contributing factors to injury. While lack of flexibility alone is commonly related to injury, there are clear differences in hamstring flexibility between males and females. To compare the effect of static hamstring length on sagittal plane mechanics between male and female runners. Forty subjects (30.0±6.4 years) participated and were placed in one of 4 groups: flexible males (n=10), inflexible males (n=10), flexible females (n=10), and inflexible females (n=10). All subjects were free of injury at the time of data collection. Three-dimensional kinematics and kinetics were collected while subjects ran over ground across 2 force platforms. Sagittal plane joint angles and moments were calculated at the knee and hip and compared with a 2-way (sex X flexibility) ANOVA (α=0.05). Males exhibited greater peak knee extension moment than females (M=2.80±0.47, F=2.48±0.52 Nm/kg*m, p=0.05) and inflexible runners exhibited greater peak knee extension moment than flexible runners (In=2.83±0.56, Fl=2.44±0.51 Nm/kg*m, p=0.01). For hip flexion at initial contact, a significant interaction existed (p<0.05). Flexible females (36.7±7.4º) exhibited more hip flexion than inflexible females (27.9±4.6º, p<0.01) and flexible males (30.1±9.5º, p<0.05). No differences existed for knee angle at initial contact, peak knee angle, peak hip angle, or peak hip moment. Hamstring flexibility results in different mechanical profiles in males and females. Flexibility in the hamstrings may result in decreased moments via active or passive tension. These differences may have implications for performance and injury in flexible female runners.
Williams III, D. S. Blaise; Welch, Lee M.
2015-01-01
ABSTRACT Background: Injuries to runners are common. However, there are many potential contributing factors to injury. While lack of flexibility alone is commonly related to injury, there are clear differences in hamstring flexibility between males and females. Objective: To compare the effect of static hamstring length on sagittal plane mechanics between male and female runners. Method: Forty subjects (30.0±6.4 years) participated and were placed in one of 4 groups: flexible males (n=10), inflexible males (n=10), flexible females (n=10), and inflexible females (n=10). All subjects were free of injury at the time of data collection. Three-dimensional kinematics and kinetics were collected while subjects ran over ground across 2 force platforms. Sagittal plane joint angles and moments were calculated at the knee and hip and compared with a 2-way (sex X flexibility) ANOVA (α=0.05). Results: Males exhibited greater peak knee extension moment than females (M=2.80±0.47, F=2.48±0.52 Nm/kg*m, p=0.05) and inflexible runners exhibited greater peak knee extension moment than flexible runners (In=2.83±0.56, Fl=2.44±0.51 Nm/kg*m, p=0.01). For hip flexion at initial contact, a significant interaction existed (p<0.05). Flexible females (36.7±7.4º) exhibited more hip flexion than inflexible females (27.9±4.6º, p<0.01) and flexible males (30.1±9.5º, p<0.05). No differences existed for knee angle at initial contact, peak knee angle, peak hip angle, or peak hip moment. Conclusion: Hamstring flexibility results in different mechanical profiles in males and females. Flexibility in the hamstrings may result in decreased moments via active or passive tension. These differences may have implications for performance and injury in flexible female runners. PMID:26537812
Wang, Jianping; Tao, Kun; Li, Huanyi; Wang, Chengtao
2014-01-01
The model of three-dimensional (3D) geometric knee was built, which included femoral-tibial, patellofemoral articulations and the bone and soft tissues. Dynamic finite element (FE) model of knee was developed to simulate both the kinematics and the internal stresses during knee flexion. The biomechanical experimental system of knee was built to simulate knee squatting using cadaver knees. The flexion motion and dynamic contact characteristics of knee were analyzed, and verified by comparing with the data from in vitro experiment. The results showed that the established dynamic FE models of knee are capable of predicting kinematics and the contact stresses during flexion, and could be an efficient tool for the analysis of total knee replacement (TKR) and knee prosthesis design. PMID:25013852
Gautam, Arvind; Callejas, Miguel A; Acharyya, Amit; Acharyya, Swati Ghosh
2018-05-01
This study introduced a shape memory alloy (SMA)-based smart knee spacer for total knee arthroplasty (TKA). Subsequently, a 3D CAD model of a smart tibial component of TKA was designed in Solidworks software, and verified using a finite element analysis in ANSYS Workbench. The two major properties of the SMA (NiTi), the pseudoelasticity (PE) and shape memory effect (SME), were exploited, modelled, and analysed for a TKA application. The effectiveness of the proposed model was verified in ANSYS Workbench through the finite element analysis (FEA) of the maximum deformation and equivalent (von Mises) stress distribution. The proposed model was also compared with a polymethylmethacrylate (PMMA)-based spacer for the upper portion of the tibial component for three subjects with body mass index (BMI) of 23.88, 31.09, and 38.39. The proposed SMA -based smart knee spacer contained 96.66978% less deformation with a standard deviation of 0.01738 than that of the corresponding PMMA based counterpart for the same load and flexion angle. Based on the maximum deformation analysis, the PMMA-based spacer had 30 times more permanent deformation than that of the proposed SMA-based spacer for the same load and flexion angle. The SME property of the lower portion of the tibial component for fixation of the spacer at its position was verified by an FEA in ANSYS. Wherein, a strain life-based fatigue analysis was performed and tested for the PE and SME built spacers through the FEA. Therefore, the SMA-based smart knee spacer eliminated the drawbacks of the PMMA-based spacer, including spacer fracture, loosening, dislocation, tilting or translation, and knee subluxation. Copyright © 2018. Published by Elsevier Ltd.
Examining Ankle-Joint Laxity Using 2 Knee Positions and With Simulated Muscle Guarding
Hanlon, Shawn; Caccese, Jaclyn; Knight, Christopher A.; Swanik, Charles “Buz”; Kaminski, Thomas W.
2016-01-01
Context: Several factors affect the reliability of the anterior drawer and talar tilt tests, including the individual clinician's experience and skill, ankle and knee positioning, and muscle guarding. Objectives: To compare gastrocnemius activity during the measurement of ankle-complex motion at different knee positions, and secondarily, to compare ankle-complex motion during a simulated trial of muscle guarding. Design: Cross-sectional study. Setting: Research laboratory. Patients or Other Participants: Thirty-three participants aged 20.2 ± 1.7 years were tested. Intervention(s): The ankle was loaded under 2 test conditions (relaxed, simulated muscle guarding) at 2 knee positions (0°, 90° of flexion) while gastrocnemius electromyography (EMG) activity was recorded. Main Outcome Measure(s): Anterior displacement (mm), inversion-eversion motion (°), and peak EMG amplitude values of the gastrocnemius (μV). Results: Anterior displacement did not differ between the positions of 0° and 90° of knee flexion (P = .193). Inversion-eversion motion was greater at 0° of knee flexion compared with 90° (P < .001). Additionally, peak EMG amplitude of the gastrocnemius was not different between 0° and 90° of knee flexion during anterior displacement (P = .101). As expected, the simulated muscle-guarding trial reduced anterior displacement compared with the relaxed condition (0° of knee flexion, P = .008; 90° of knee flexion, P = .016) and reduced inversion-eversion motion (0° of knee flexion, P = .03; 90° of knee flexion, P < .001). Conclusions: In a relaxed state, the gastrocnemius muscle did not appear to affect anterior ankle laxity at the 2 most common knee positions for anterior drawer testing; however, talar tilt testing may be best performed with the knee in 0° of knee flexion. Finally, our outcomes from the simulated muscle-guarding condition suggest that clinicians should use caution and be aware of reduced perceived laxity when performing these clinical examination techniques immediately postinjury. PMID:26881870
Examining Ankle-Joint Laxity Using 2 Knee Positions and With Simulated Muscle Guarding.
Hanlon, Shawn; Caccese, Jaclyn; Knight, Christopher A; Swanik, Charles Buz; Kaminski, Thomas W
2016-02-01
Several factors affect the reliability of the anterior drawer and talar tilt tests, including the individual clinician's experience and skill, ankle and knee positioning, and muscle guarding. To compare gastrocnemius activity during the measurement of ankle-complex motion at different knee positions, and secondarily, to compare ankle-complex motion during a simulated trial of muscle guarding. Cross-sectional study. Research laboratory. Thirty-three participants aged 20.2 ± 1.7 years were tested. The ankle was loaded under 2 test conditions (relaxed, simulated muscle guarding) at 2 knee positions (0°, 90° of flexion) while gastrocnemius electromyography (EMG) activity was recorded. Anterior displacement (mm), inversion-eversion motion (°), and peak EMG amplitude values of the gastrocnemius (μV). Anterior displacement did not differ between the positions of 0° and 90° of knee flexion (P = .193). Inversion-eversion motion was greater at 0° of knee flexion compared with 90° (P < .001). Additionally, peak EMG amplitude of the gastrocnemius was not different between 0° and 90° of knee flexion during anterior displacement (P = .101). As expected, the simulated muscle-guarding trial reduced anterior displacement compared with the relaxed condition (0° of knee flexion, P = .008; 90° of knee flexion, P = .016) and reduced inversion-eversion motion (0° of knee flexion, P = .03; 90° of knee flexion, P < .001). In a relaxed state, the gastrocnemius muscle did not appear to affect anterior ankle laxity at the 2 most common knee positions for anterior drawer testing; however, talar tilt testing may be best performed with the knee in 0° of knee flexion. Finally, our outcomes from the simulated muscle-guarding condition suggest that clinicians should use caution and be aware of reduced perceived laxity when performing these clinical examination techniques immediately postinjury.
Omorczyk, Jarosław; Nosiadek, Leszek; Ambroży, Tadeusz; Nosiadek, Andrzej
2015-01-01
The main aim of this study was to verify the usefulness of selected simple methods of recording and fast biomechanical analysis performed by judges of artistic gymnastics in assessing a gymnast's movement technique. The study participants comprised six artistic gymnastics judges, who assessed back handsprings using two methods: a real-time observation method and a frame-by-frame video analysis method. They also determined flexion angles of knee and hip joints using the computer program. In the case of the real-time observation method, the judges gave a total of 5.8 error points with an arithmetic mean of 0.16 points for the flexion of the knee joints. In the high-speed video analysis method, the total amounted to 8.6 error points and the mean value amounted to 0.24 error points. For the excessive flexion of hip joints, the sum of the error values was 2.2 error points and the arithmetic mean was 0.06 error points during real-time observation. The sum obtained using frame-by-frame analysis method equaled 10.8 and the mean equaled 0.30 error points. Error values obtained through the frame-by-frame video analysis of movement technique were higher than those obtained through the real-time observation method. The judges were able to indicate the number of the frame in which the maximal joint flexion occurred with good accuracy. Using the real-time observation method as well as the high-speed video analysis performed without determining the exact angle for assessing movement technique were found to be insufficient tools for improving the quality of judging.
Song, Young Dong; Jain, Nimash; Kang, Yeon Gwi; Kim, Tae Yune; Kim, Tae Kyun
2016-06-01
Correlations between maximum flexion and functional outcomes in total knee arthroplasty (TKA) patients are reportedly weak. We investigated whether there are differences between passive maximum flexion in nonweight bearing and other types of maximum flexion and whether the type of maximum flexion correlates with functional outcomes. A total of 210 patients (359 knees) underwent preoperative evaluation and postoperative follow-up evaluations (6, 12, and 24 months) for the assessment of clinical outcomes including maximum knee flexion. Maximum flexion was measured under five conditions: passive nonweight bearing, passive weight bearing, active nonweight bearing, and active weight bearing with or without arm support. Data were analyzed for relationships between passive maximum flexion in nonweight bearing by Pearson correlation analyses, and a variance comparison between measurement techniques via paired t test. We observed substantial differences between passive maximum flexion in nonweight bearing and the other four maximum flexion types. At all time points, passive maximum flexion in nonweight bearing correlated poorly with active maximum flexion in weight bearing with or without arm support. Active maximum flexion in weight bearing better correlated with functional outcomes than the other maximum flexion types. Our study suggests active maximum flexion in weight bearing should be reported together with passive maximum flexion in nonweight bearing in research on the knee motion arc after TKA.
Song, Young Dong; Jain, Nimash; Kang, Yeon Gwi; Kim, Tae Yune
2016-01-01
Purpose Correlations between maximum flexion and functional outcomes in total knee arthroplasty (TKA) patients are reportedly weak. We investigated whether there are differences between passive maximum flexion in nonweight bearing and other types of maximum flexion and whether the type of maximum flexion correlates with functional outcomes. Materials and Methods A total of 210 patients (359 knees) underwent preoperative evaluation and postoperative follow-up evaluations (6, 12, and 24 months) for the assessment of clinical outcomes including maximum knee flexion. Maximum flexion was measured under five conditions: passive nonweight bearing, passive weight bearing, active nonweight bearing, and active weight bearing with or without arm support. Data were analyzed for relationships between passive maximum flexion in nonweight bearing by Pearson correlation analyses, and a variance comparison between measurement techniques via paired t test. Results We observed substantial differences between passive maximum flexion in nonweight bearing and the other four maximum flexion types. At all time points, passive maximum flexion in nonweight bearing correlated poorly with active maximum flexion in weight bearing with or without arm support. Active maximum flexion in weight bearing better correlated with functional outcomes than the other maximum flexion types. Conclusions Our study suggests active maximum flexion in weight bearing should be reported together with passive maximum flexion in nonweight bearing in research on the knee motion arc after TKA. PMID:27274468
Sakai, Norihiro; Inoue, Takaya; Kunugiza, Yasuo; Tomita, Tetsuya; Mashimo, Takashi
2013-05-01
We conducted the prospective randomized controlled trial to test that continuous femoral nerve block (CFNB) improves attainment of 120° knee flexion compared to continuous epidural analgesia (CEA). Sixty-six patients scheduled for unilateral total knee arthroplasty were randomized into two groups; infusion of ropivacaine 0.15% into CEA or CFNB to third postoperative days. We studied the time required to attain 120° knee flexion, variations in thigh and calf circumferences around the treated knee, pain scores, rehabilitation milestones, the need for adjuvant analgesics, and side effects. CFNB patients attained earlier knee flexion to 120°, lower variations in thigh and calf circumferences, less pain during rehabilitation, and less need for adjuvant analgesics. CFNB is a better pain management strategy that accelerates knee flexion rehabilitation. Copyright © 2013 Elsevier Inc. All rights reserved.
The collision forces and lower-extremity inter-joint coordination during running.
Wang, Li-I; Gu, Chin-Yi; Wang, I-Lin; Siao, Sheng-Wun; Chen, Szu-Ting
2018-06-01
The purpose of this study was to compare the lower extremity inter-joint coordination of different collision forces runners during running braking phase. A dynamical system approach was used to analyse the inter-joint coordination parameters. Data were collected with six infra-red cameras and two force plates. According to the impact peak of the vertical ground reaction force, twenty habitually rearfoot-strike runners were categorised into three groups: high collision forces runners (HF group, n = 8), medium collision forces runners (MF group, n = 5), and low collision forces runners (LF group, n = 7). There were no significant differences among the three groups in the ankle and knee joint angle upon landing and in the running velocity (p > 0.05). The HF group produced significantly smaller deviation phase (DP) of the hip flexion/extension-knee flexion/extension during the braking phase compared with the MF and LF groups (p < 0.05). The DP of the hip flexion/extension-knee flexion/extension during the braking phase correlated negatively with the collision force (p < 0.05). The disparities regarding the flexibility of lower extremity inter-joint coordination were found in high collision forces runners. The efforts of the inter-joint coordination and the risk of running injuries need to be clarified further.
Hahn, D; Bakenecker, P; Zinke, F
2017-12-01
Torque production during maximal voluntary explosive contractions is considered to be a functionally more relevant neuromuscular measure than steady-state torque, but little is known about accelerated concentric contractions. This study investigated torque, muscle activity, and fascicle behavior during isometric and fast concentric contractions of quadriceps femoris. Ten participants performed maximal voluntary explosive isometric, isovelocity, and additional concentric knee extensions at angular accelerations ranging from 700 to 4000° s -2 that resulted in an angular velocity of 300° s -1 at 40° knee flexion. Concentric torque at 40° knee flexion was corrected for inertia, and the corresponding isometric torque was matched to the time when the target knee angle of 40° was reached during concentric contractions. Electromyography of quadriceps femoris and hamstrings and ultrasound of vastus lateralis were measured to determine muscle activity, fascicle length, and fascicle velocity (FV). The faster the acceleration, the more torque was produced during concentric contractions at 40° knee flexion, which was accompanied by a reduction in FV. In comparison with isometric conditions, concentric quadriceps muscle activity was increased and torque during accelerations ≥3000° s -2 equaled the time-matched isometric torque. Our results provide novel evidence that acceleration influences torque production during maximal voluntary explosive concentric contractions. This is suggested to be due to series elasticity and reduced force depression. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Influence of bi- and tri-compartmental knee arthroplasty on the kinematics of the knee joint.
Wünschel, Markus; Lo, Jiahsuan; Dilger, Torsten; Wülker, Nikolaus; Müller, Otto
2011-01-27
The cruciate ligaments are important stabilizers of the knee joint and determine joint kinematics in the natural knee and after cruciate retaining arthroplasty.No in vitro data is available to biomechanically evaluate the ability of the anterior cruciate ligament (ACL) to maintain knee joint kinematics after bicruciate-retaining bi-compartmental knee arthroplasty (BKA).Therefore, the objective of the current study was to investigate the kinematics of the natural knee joint, before and after installing bicruciate-retaining BKA and posterior cruciate retaining total knee arthroplasty. Specifically, we incorporated a dynamic knee simulator to simulate weight-bearing flexions on cadaveric knee specimen before and after surgical manipulations. In this cadaveric study we investigated rotational and translational tibiofemoral kinematics during simulated weight-bearing flexions of the intact knee, after bi-compartmental knee arthroplasty (BKA+), after resecting the ACL in BKA (BKA-), and after posterior cruciate retaining total knee arthroplasty (TKA). Rotation of BKA+ is closest to the intact knee joint, whereas TKA shows significant differences from 30 to 90 degree of flexion. Within the tested flexion range (15 to 90 degree of flexion), there was no significant difference in the anterior-posterior translation among intact, BKA+, and TKA knees. Resecting the ACL in BKA leads to a significant anterior tibial translation. BKA with intact cruciate ligaments resembles rotation and translation of the natural knee during a simulated weight-bearing flexion. It is a suitable treatment option for medial and patellofemoral osteoarthritis with advantages in rotational characteristics compared to TKA.
Fujita, Remi; Matsui, Yasumoto; Harada, Atsushi; Takemura, Marie; Kondo, Izumi; Nemoto, Tetsuya; Sakai, Tadahiro; Hiraiwa, Hideki; Ota, Susumu
2016-12-01
[Purpose] The purpose of this study was to elucidate the relationship between knee muscle strength and knee pain in activities of daily living, based on consideration of the difference between extension and flexion strength (Q - H) and the hamstring:quadriceps (H:Q) ratio in patients with knee osteoarthritis. [Subjects and Methods] The participants were 78 females with knee osteoarthritis, and a total of 133 knees that had not been treated surgically were the targets of this research. The legs were divided according to dominance. Isometric knee extension and flexion muscle strength and knee pain during activities of daily living were measured. The H:Q ratio (flexion/extension muscle strength) and the difference between extension and flexion strength, (extension muscle strength/weight) minus (flexion muscle strength/weight), that is, Q - H, were calculated. The correlation between these indices and the knee pain score during activities of daily living was investigated. [Results] Greater knee pain during activities of daily living was related to lower knee extension muscle strength and Q - H in both the dominant and nondominant legs. Knee flexion muscle strength and the H:Q ratio were not significantly correlated with knee pain during any activities of daily living. [Conclusion] Knee extension muscle strength and Q - H were found to be significantly correlated with knee pain during activities of daily living, whereas the H:Q ratio was not.
Analysis of the Flexion Gap on In Vivo Knee Kinematics Using Fluoroscopy.
Nakamura, Shinichiro; Ito, Hiromu; Yoshitomi, Hiroyuki; Kuriyama, Shinichi; Komistek, Richard D; Matsuda, Shuichi
2015-07-01
There is a paucity of information on the relationships between postoperative knee laxity and in vivo knee kinematics. The correlations were analyzed in 22 knees with axial radiographs and fluoroscopy based 3D model fitting approach after a tri-condylar total knee arthroplasty. During deep knee bend activities, the medial flexion gap had significant correlations with the medial contact point (r=0.529, P=0.011) and axial rotation at full extension. During kneeling activities, a greater medial flexion gap caused larger anterior translation at complete contact (r=0.568, P=0.011). Meanwhile, the lateral flexion gap had less effect. In conclusion, laxity of the medial collateral ligament should be avoided because the magnitude of medial flexion stability was crucial for postoperative knee kinematics. Copyright © 2015 Elsevier Inc. All rights reserved.
Markolf, K L; Kochan, A; Amstutz, H C
1984-02-01
Thirty-five patients with documented absence of the anterior cruciate ligament were tested on the University of California, Los Angeles, instrumented clinical knee-testing apparatus and we measured the response curves for the following testing modes: anterior-posterior force versus displacement at full extension and at 20 and 90 degrees of flexion; varus-valgus moment versus angulation at full extension and 20 degrees of flexion; and tibial torque versus rotation at 20 degrees of flexion. Absolute values of stiffness and laxity and right-left differences for these injured knees were compared with identical quantities measured previously for a control population of forty-nine normal subjects with no history of treatment for injury to the knee. For both the uninjured knees and the knees without an anterior cruciate ligament, at 20 and 90 degrees of flexion the anterior-posterior laxity was greatest at approximately 15 degrees of external rotation of the foot. The injured knees demonstrated significantly increased total anterior-posterior laxity and decreased anterior stiffness when compared with the uninjured knees in all tested positions of the foot and knee. The mean increase in paired anterior-posterior laxity for the injured knees in this group of patients at +/- 200 newtons of applied anterior-posterior force was 3.1 millimeters (+39 per cent) at full extension, 5.5 millimeters (+57 per cent) at 20 degrees of flexion, and 2.5 millimeters (+34 per cent) at 90 degrees of flexion. The mean reduction in anterior stiffness for injured knees was also greatest (-54 per cent) at 20 degrees of knee flexion. Only slight reduction in posterior stiffness (-16 per cent) was measured at 20 degrees of flexion, and this probably reflected the presence of associated capsular and meniscal injuries. In the group of anterior cruciate-deficient knees, the patients with an absent medial meniscus showed greater total anterior-posterior laxity in all three positions of knee flexion than did the patients with an intact or torn meniscus. Varus-valgus laxity at full extension increased an average of 1.7 degrees (+36 per cent) for the injured knees, while varus and valgus stiffness decreased 21 per cent and 24 per cent. Absence of the medial meniscus (in a knee with absence of the anterior cruciate ligament) increased varus-valgus laxity at zero and 20 degrees of flexion.(ABSTRACT TRUNCATED AT 400 WORDS)
Jalali, Maryam; Farahmand, Farzam; Mousavi, Seyed Mohammad Ebrahim; Golestanha, Seyed Ali; Rezaeian, Tahmineh; Shirvani Broujeni, Shahram; Rahgozar, Mehdi; Esfandiarpour, Fateme
2015-01-01
Background: Despite several studies with different methods, the effect of functional knee braces on knee joint kinematics is not clear. Direct visualization of joint components through medical imaging modalities may provide the clinicians with more useful information. Objectives: In this study, for the first time in the literature, video fluoroscopy was used to investigate the effect of knee bracing on the sagittal plane kinematics of anterior cruciate ligament (ACL) injured patients. Patients and Methods: For twelve male unilateral ACL deficient subjects, the anterior tibial translation was measured during lunge exercise in non-braced and braced conditions. Fluoroscopic images were acquired from the subjects using a digital fluoroscopy system with a rate of 10 fps. The image of each frame was scaled using a calibration coin and analyzed in AutoCAD environment. The angle between the two lines, tangent to the posterior cortexes of the femoral and tibial shafts was measured as the flexion angle. For the fluoroscopic images associated with 0°, 15°, 30°, 45° and 60° knee flexion angles, the relative anterior-posterior configuration of the tibiofemoral joint was assessed by measuring the position of landmarks on the tibia and femur. Results: Results indicated that the overall anterior translations of the tibia during the eccentric (down) and concentric (up) phases of lunge exercise were 10.4 ± 1.7 mm and 9.0 ± 2.2 mm for non-braced, and 10.1 ± 3.4 mm and 7.4 ± 2.5 mm, for braced conditions, respectively. The difference of the tibial anterior-posterior translation behaviors of the braced and non-braced knees was not statistically significant. Conclusion: Fluoroscopic imaging provides an effective tool to measure the dynamic behavior of the knee joint in the sagittal plane and within the limitations of this study, the pure mechanical stabilizing effect of functional knee bracing is not sufficient to control the anterior tibial translation of the ACL deficient patients during lunge exercise. PMID:26557277
Smartphone assessment of knee flexion compared to radiographic standards.
Dietz, Matthew J; Sprando, Daniel; Hanselman, Andrew E; Regier, Michael D; Frye, Benjamin M
2017-03-01
Measuring knee range of motion (ROM) is an important assessment for the outcomes of total knee arthroplasty. Recent technological advances have led to the development and use of accelerometer-based smartphone applications to measure knee ROM. The purpose of this study was to develop, standardize, and validate methods of utilizing smartphone accelerometer technology compared to radiographic standards, visual estimation, and goniometric evaluation. Participants used visual estimation, a long-arm goniometer, and a smartphone accelerometer to determine range of motion of a cadaveric lower extremity; these results were compared to radiographs taken at the same angles. The optimal smartphone position was determined to be on top of the leg at the distal femur and proximal tibia location. Between methods, it was found that the smartphone and goniometer were comparably reliable in measuring knee flexion (ICC=0.94; 95% CI: 0.91-0.96). Visual estimation was found to be the least reliable method of measurement. The results suggested that the smartphone accelerometer was non-inferior when compared to the other measurement techniques, demonstrated similar deviations from radiographic standards, and did not appear to be influenced by the person performing the measurements or the girth of the extremity. Copyright © 2016 Elsevier B.V. All rights reserved.
Smartphone Assessment of Knee Flexion Compared to Radiographic Standards
Dietz, Matthew J.; Sprando, Daniel; Hanselman, Andrew E.; Regier, Michael D.; Frye, Benjamin M.
2017-01-01
Purpose Measuring knee range of motion (ROM) is an important assessment for the outcomes of total knee arthroplasty. Recent technological advances have led to the development and use of accelerometer-based smartphone applications to measure knee ROM. The purpose of this study was to develop, standardize, and validate methods of utilizing smartphone accelerometer technology compared to radiographic standards, visual estimation, and goniometric evaluation. Methods Participants used visual estimation, a long-arm goniometer, and a smartphone accelerometer to determine range of motion of a cadaveric lower extremity; these results were compared to radiographs taken at the same angles. Results The optimal smartphone position was determined to be on top of the leg at the distal femur and proximal tibia location. Between methods, it was found that the smartphone and goniometer were comparably reliable in measuring knee flexion (ICC = 0.94; 95% CI: 0.91–0.96). Visual estimation was found to be the least reliable method of measurement. Conclusions The results suggested that the smartphone accelerometer was non-inferior when compared to the other measurement techniques, demonstrated similar deviations from radiographic standards, and did not appear to be influenced by the person performing the measurements or the girth of the extremity. PMID:28179062
LaPrade, Christopher M; Jansson, Kyle S; Dornan, Grant; Smith, Sean D; Wijdicks, Coen A; LaPrade, Robert F
2014-03-19
An avulsion of the posterior root attachment of the lateral meniscus or a radial tear close to the root attachment can lead to degenerative knee arthritis. Although the biomechanical effects of comparable injuries involving the medial meniscus have been studied, we are aware of no such study involving the lateral meniscus. We hypothesized that in situ pull-out suture repair of lateral meniscus root avulsions and of complete radial tears 3 and 6 mm from the root attachment would increase the contact area and decrease mean and peak tibiofemoral contact pressures, at all knee flexion angles, relative to the corresponding avulsion or tear condition. Eight human cadaveric knees underwent biomechanical testing. Eight lateral meniscus conditions (intact, footprint tear, root avulsion, root avulsion repair, radial tears at 3 and 6 mm from the posterior root, and repairs of the 3 and 6-mm tears) were tested at five different flexion angles (0°, 30°, 45°, 60°, and 90°) under a compressive 1000-N load. Avulsion of the posterior root of the lateral meniscus or an adjacent radial tear resulted in significantly decreased contact area and increased mean and peak contact pressures in the lateral compartment, relative to the intact condition, in all cases except the root avulsion condition at 0° of flexion. In situ pull-out suture repair of the root avulsion or radial tear significantly reduced mean contact pressures, relative to the corresponding avulsion or tear condition, when the results for each condition were pooled across all flexion angles. Posterior horn root avulsions and radial tears adjacent to the root attachment of the lateral meniscus significantly increased contact pressures in the lateral compartment. In situ pull-out suture repairs of these tears significantly improved lateral compartment joint contact pressures. In situ repair may be an effective treatment to improve tibiofemoral contact profiles after an avulsion of the posterior root of the lateral meniscus or a complete radial tear adjacent to the root. In situ repairs should be further investigated clinically as an alternative to partial lateral meniscectomy.
Patello-femoral and tibio-femoral contact forces during kicking type of activity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Engin, A.E.; Tumer, S.T.
1996-12-31
In this paper patello-femoral and tibia-femoral contact forces during kicking type of activity is presented by means of a dynamic model of the knee joint which includes tibio-femoral and patello-femoral articulations, and the major ligaments of the joint. The model shows that the patella can be subjected to very large transient patello-femoral contact forces during a strenuous lower limb activity such as kicking even under conditions of small knee-flexion angles.
Cuéllar, Adrián; Cuéllar, Ricardo; Cuéllar, Asier; Garcia-Alonso, Ignacio; Ruiz-Ibán, Miguel Angel
2015-11-01
To evaluate if different knee flexion angles can modify the neurovascular injury risk during lateral meniscus repair. Twenty cadaveric knees were studied. An all-inside suture device (FasT-Fix; Smith & Nephew, Andover, MA) was placed at the posterior horn and at the medial and lateral limits of the popliteal hiatus. The minimal distances between the device and the popliteal artery and peroneal nerve were measured with the knee at 90°, 45°, and 0° of flexion through a limited posterolateral arthrotomy. The distance between the device when inserted at the lateral edge of the popliteal hiatus and the peroneal nerve decreased from a median of 26 mm (interquartile range [IQR], 3.5 mm; range, 19 to 29 mm) at 90° to 21.5 mm (IQR, 4.5 mm; range, 14 to 25 mm) at 45° and 15.5 mm (IQR, 6.5 mm; range, 4 to 20 mm) at 0° (significant differences, P < .001). The distance between the device when inserted at the medial edge of the popliteal hiatus and the peroneal nerve decreased from 16 mm (IQR, 3.3 mm; range, 9 to 21 mm) at 90° to 12 mm (IQR, 4.3 mm; range, 9 to 16 mm) at 45° and 7 mm (IQR, 4.0; range, 4 to 15 mm) at 0° (significant differences, P < .001). The distance between the device when inserted at the medial edge of the popliteal hiatus and the popliteal artery decreased from 21 mm (IQR, 5.0 mm; range, 11 to 27 mm) at 90° to 19 mm (IQR, 5.0 mm; range, 10 to 23 mm) at 45° and 16 mm (IQR, 7.5 mm; range, 10 to 23 mm) at 0° (significant differences, P < .001). The distance between the device when inserted 5 mm lateral to the posterior root of the lateral meniscus and the popliteal artery decreased from 13 mm (IQR, 4.3 mm; range, 7 to 27 mm) at 90° to 10.5 mm (IQR, 4.3 mm; range, 4 to 19 mm) at 45° and 5.5 mm (IQR, 4.0 mm; range, 0 to 14 mm) at 0° (significant differences, P < .001). The risk of injury to the popliteal artery or to the peroneal nerve during all-inside repair of the posterior half of the lateral meniscus is lower at 90° of flexion and increases with knee extension to 45° and 0°. All-inside meniscal repair of the lateral meniscus is safer with the knee at 90° of flexion. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Frontal plane landing mechanics in high-arched compared with low-arched female athletes.
Powell, Douglas W; Hanson, Nicholas J; Long, Benjamin; Williams, D S Blaise
2012-09-01
To examine ground reaction forces (GRFs); frontal plane hip, knee, and ankle joint angles; and moments in high-arched (HA) and low-arched (LA) athletes during landing. Experimental study. Controlled research laboratory. Twenty healthy female recreational athletes (10 HA and 10 LA). Athletes performed 5 barefoot drop landings from a height of 30 cm. Frontal plane ankle, knee, and hip joint angles (in degrees) at initial contact, peak vertical GRF, and peak knee flexion; peak ankle, knee, and hip joint moments in the frontal plane. Vertical GRF profiles were similar between HA and LA athletes (P = 0.78). The HA athletes exhibited significantly smaller peak ankle inversion angles than the LA athletes (P = 0.01) at initial contact. At peak vertical GRF, HA athletes had significantly greater peak knee (P = 0.01) and hip abduction angles than LA athletes (P = 0.02). There were no significant differences between HA and LA athletes in peak joint moments (hip: P = 0.68; knee: P = 0.71; ankle: P = 0.15). These findings demonstrate that foot type is associated with altered landing mechanics, which may underlie lower extremity injuries. The ankle-driven strategy previously reported in female athletes suggests that foot function may have a greater relationship with lower extremity injury than that in male athletes. Future research should address the interaction of foot type and gender during landing tasks.
Hamstrings Stiffness and Landing Biomechanics Linked to Anterior Cruciate Ligament Loading
Blackburn, J. Troy; Norcross, Marc F.; Cannon, Lindsey N.; Zinder, Steven M.
2013-01-01
Context: Greater hamstrings stiffness is associated with less anterior tibial translation during controlled perturbations. However, it is unclear how hamstrings stiffness influences anterior cruciate ligament (ACL) loading mechanisms during dynamic tasks. Objective: To evaluate the influence of hamstrings stiffness on landing biomechanics related to ACL injury. Design: Cross-sectional study. Setting: Research laboratory. Patients or Other Participants: A total of 36 healthy, physically active volunteers (18 men, 18 women; age = 23 ± 3 years, height = 1.8 ± 0.1 m, mass = 73.1 ± 16.6 kg). Intervention(s): Hamstrings stiffness was quantified via the damped oscillatory technique. Three-dimensional lower extremity kinematics and kinetics were captured during a double-legged jump-landing task via a 3-dimensional motion-capture system interfaced with a force plate. Landing biomechanics were compared between groups displaying high and low hamstrings stiffness via independent-samples t tests. Main Outcome Measure(s): Hamstrings stiffness was normalized to body mass (N/m·kg−1). Peak knee-flexion and -valgus angles, vertical and posterior ground reaction forces, anterior tibial shear force, internal knee-extension and -varus moments, and knee-flexion angles at the instants of each peak kinetic variable were identified during the landing task. Forces were normalized to body weight, whereas moments were normalized to the product of weight and height. Results: Internal knee-varus moment was 3.6 times smaller in the high-stiffness group (t22 = 2.221, P = .02). A trend in the data also indicated that peak anterior tibial shear force was 1.1 times smaller in the high-stiffness group (t22 = 1.537, P = .07). The high-stiffness group also demonstrated greater knee flexion at the instants of peak anterior tibial shear force and internal knee-extension and -varus moments (t22 range = 1.729–2.224, P < .05). Conclusions: Greater hamstrings stiffness was associated with landing biomechanics consistent with less ACL loading and injury risk. Musculotendinous stiffness is a modifiable characteristic; thus exercises that enhance hamstrings stiffness may be important additions to ACL injury-prevention programs. PMID:24303987
Influence of bi- and tri-compartmental knee arthroplasty on the kinematics of the knee joint
2011-01-01
Background The cruciate ligaments are important stabilizers of the knee joint and determine joint kinematics in the natural knee and after cruciate retaining arthroplasty. No in vitro data is available to biomechanically evaluate the ability of the anterior cruciate ligament (ACL) to maintain knee joint kinematics after bicruciate-retaining bi-compartmental knee arthroplasty (BKA). Therefore, the objective of the current study was to investigate the kinematics of the natural knee joint, before and after installing bicruciate-retaining BKA and posterior cruciate retaining total knee arthroplasty. Specifically, we incorporated a dynamic knee simulator to simulate weight-bearing flexions on cadaveric knee specimen before and after surgical manipulations. Methods In this cadaveric study we investigated rotational and translational tibiofemoral kinematics during simulated weight-bearing flexions of the intact knee, after bi-compartmental knee arthroplasty (BKA+), after resecting the ACL in BKA (BKA-), and after posterior cruciate retaining total knee arthroplasty (TKA). Results Rotation of BKA+ is closest to the intact knee joint, whereas TKA shows significant differences from 30 to 90 degree of flexion. Within the tested flexion range (15 to 90 degree of flexion), there was no significant difference in the anterior-posterior translation among intact, BKA+, and TKA knees. Resecting the ACL in BKA leads to a significant anterior tibial translation. Conclusions BKA with intact cruciate ligaments resembles rotation and translation of the natural knee during a simulated weight-bearing flexion. It is a suitable treatment option for medial and patellofemoral osteoarthritis with advantages in rotational characteristics compared to TKA. PMID:21272328
Antagonist muscle co-contraction during a double-leg landing maneuver at two heights.
Mokhtarzadeh, Hossein; Yeow, Chen Hua; Goh, James Cho Hong; Oetomo, Denny; Ewing, Katie; Lee, Peter Vee Sin
2017-10-01
Knee injuries are common during landing activities. Greater landing height increases peak ground reaction forces (GRFs) and loading at the knee joint. As major muscles to stabilize the knee joint, Quadriceps and Hamstring muscles provide internal forces to attenuate the excessive GRF. Despite the number of investigations on the importance of muscle function during landing, the role of landing height on these muscles forces using modeling during landing is not fully investigated. Participant-specific musculoskeletal models were developed using experimental motion analysis data consisting of anatomic joint motions and GRF from eight male participants performing double-leg drop landing from 30 and 60 cm. Muscle forces were calculated in OpenSim and their differences were analyzed at the instances of high risk during landing i.e. peak GRF for both heights. The maximum knee flexion angle and moments were found significantly higher from a double-leg landing at 60 cm compared to 30 cm. The results showed elevated GRF, and mean muscle forces during landing. At peak GRF, only quadriceps showed significantly greater forces at 60 cm. Hamstring muscle forces did not significantly change at 60 cm compared to 30 cm. Quadriceps and hamstring muscle forces changed at different heights. Since hamstring forces were similar in both landing heights, this could lead to an imbalance between the antagonist muscles, potentially placing the knee at risk of injury if combined with small flexion angles that was not observed at peak GRF in our study. Thus, enhanced neuromuscular training programs strengthening the hamstrings may be required to address this imbalance. These findings may contribute to enhance neuromuscular training programs to prevent knee injuries during landing.
Biomechanical analysis of the single‐leg decline squat
Zwerver, J; Bredeweg, S W; Hof, A L
2007-01-01
Background The single‐leg squat on a 25° decline board has been described as a clinical assessment tool and as a rehabilitation exercise for patients with patellar tendinopathy. Several assumptions have been made about its working mechanism on patellar load and patellofemoral forces, but these are not substantiated by biomechanical evaluations. Aim To investigate knee moment and patellofemoral contact force as a function of decline angle in the single‐leg squat. Methods Five subjects performed single‐leg eccentric squats at decline angles of 0°, 5°, 10°, 15°, 20° and 25° (with/without a backpack of 10 kg), and 30° on a board that was placed over a forceplate. Kinematic and forceplate data were recorded by the Optotrak system. Joint moments of ankle, knee and hip were calculated by two‐dimensional inverse dynamics. Results Knee moment increased by 40% at decline angles of 15° and higher, whereas hip and ankle moment decreased. Maximum knee and ankle angles increased with steeper decline. With a 10 kg backpack at 25° decline, the knee moment was 23% higher than unloaded. Both patellar tendon and patellofemoral forces increased with higher decline angles, but beyond 60°, the patellofemoral force rose steeper than the tendon force. Conclusions All single‐leg squats at decline angles >15° result in 40% increase in maximum patellar tendon force. In knee flexions >60°, patellofemoral forces increase more than patellar tendon forces. Higher tendon load can be achieved by the use of a backpack with extra weight. PMID:17224441
Squatting Exercises in Older Adults: Kinematic and Kinetic Comparisons
FLANAGAN, SEAN; SALEM, GEORGE J.; WANG, MAN-YING; SANKER, SERENA E.; GREENDALE, GAIL A.
2012-01-01
Purpose Squatting activities may be used, within exercise programs, to preserve physical function in older adults. This study characterized the lower-extremity peak joint angles, peak moments, powers, work, impulse, and muscle recruitment patterns (electromyographic; EMG) associated with two types of squatting activities in elders. Methods Twenty-two healthy, older adults (ages 70–85) performed three trials each of: 1) a squat to a self-selected depth (normal squat; SQ) and 2) a squat onto a chair with a standardized height of 43.8 cm (chair squat; CSQ). Descending and ascending phase joint kinematics and kinetics were obtained using a motion analysis system and inverse dynamics techniques. Results were averaged across the three trials. A 2 × 2 (activity × phase) ANOVA with repeated measures was used to examine the biomechanical differences among the two activities and phases. EMG temporal characteristics were qualitatively examined. Results CSQ generated greater hip flexion angles, peak moments, power, and work, whereas SQ generated greater knee and ankle flexion angles, peak moments, power, and work. SQ generated a greater knee extensor impulse, a greater plantar flexor impulse and a greater total support impulse. The EMG temporal patterns were consistent with the kinetic data. Conclusions The results suggest that, with older adults, CSQ places greater demand on the hip extensors, whereas SQ places greater demand on the knee extensors and ankle plantar flexors. Clinicians may use these discriminate findings to more effectively target specific lower-extremity muscle groups when prescribing exercise for older adults. PMID:12673148
Influence of the posterior tibial slope on the flexion gap in total knee arthroplasty.
Okazaki, Ken; Tashiro, Yasutaka; Mizu-uchi, Hideki; Hamai, Satoshi; Doi, Toshio; Iwamoto, Yukihide
2014-08-01
Adjusting the joint gap length to be equal in both extension and flexion is an important issue in total knee arthroplasty (TKA). It is generally acknowledged that posterior tibial slope affects the flexion gap; however, the extent to which changes in the tibial slope angle directly affect the flexion gap remains unclear. This study aimed to clarify the influence of tibial slope changes on the flexion gap in cruciate-retaining (CR) or posterior-stabilizing (PS) TKA. The flexion gap was measured using a tensor device with the femoral trial component in 20 cases each of CR- and PS-TKA. A wedge plate with a 5° inclination was placed on the tibial cut surface by switching its front-back direction to increase or decrease the tibial slope by 5°. The flexion gap after changing the tibial slope was compared to that of the neutral slope measured with a flat plate that had the same thickness as that of the wedge plate center. When the tibial slope decreased or increased by 5°, the flexion gap decreased or increased by 1.9 ± 0.6mm or 1.8 ± 0.4mm, respectively, with CR-TKA and 1.2 ± 0.4mm or 1.1 ± 0.3mm, respectively, with PS-TKA. The influence of changing the tibial slope by 5° on the flexion gap was approximately 2mm with CR-TKA and 1mm with PS-TKA. This information is useful when considering the effect of manipulating the tibial slope on the flexion gap when performing CR- or PS-TKA. Copyright © 2014 Elsevier B.V. All rights reserved.
Joint Angular Velocity in Spastic Gait and the Influence of Muscle-Tendon Lengthening*
GRANATA, KEVIN P.; ABEL, MARK F.; DAMIANO, DIANE L.
2006-01-01
Background Joint angular velocity (the rate of flexion and extension of a joint) is related to the dynamics of muscle activation and force generation during walking. Therefore, the goal of this research was to examine the joint angular velocity in normal and spastic gait and changes resulting from muscle-tendon lengthening (recession and tenotomy) in patients who have spastic cerebral palsy. Methods The gait patterns of forty patients who had been diagnosed with spastic cerebral palsy (mean age, 8.3 years; range, 3.7 to 14.8 years) and of seventy-three age-matched, normally developing subjects were evaluated with three-dimensional motion analysis and electromyography. The patients who had cerebral palsy were evaluated before muscle-tendon lengthening and nine months after treatment. Results The gait patterns of the patients who had cerebral palsy were characterized by increased flexion of the knee in the stance phase, premature plantar flexion of the ankle, and reduced joint angular velocities compared with the patterns of the normally developing subjects. Even though muscle-tendon lengthening altered sagittal joint angles in gait, the joint angular velocities were generally unchanged at the hip and knee. Only the ankle demonstrated modified angular velocities, including reduced dorsiflexion velocity at foot-strike and improved dorsiflexion velocity through midstance, after treatment. Electromyographic changes included reduced amplitude of the gastrocnemius-soleus during the loading phase and decreased knee coactivity (the ratio of quadriceps and hamstring activation) at toe-off. Principal component analyses showed that, compared with joint-angle data, joint angular velocity was better able to discriminate between the gait patterns of the normal and cerebral palsy groups. Conclusions This study showed that muscle-tendon lengthening corrects biomechanical alignment as reflected by changes in sagittal joint angles. However, joint angular velocity and electromyographic data suggest that the underlying neural input remains largely unchanged at the hip and knee. Conversely, electromyographic changes and changes in velocity in the ankle indicate that the activation pattern of the gastrocnemius-soleus complex in response to stretch was altered by recession of the complex. PMID:10682726
Influence of maturation on instep kick biomechanics in female soccer athletes.
Lyle, Mark A; Sigward, Susan M; Tsai, Liang-Ching; Pollard, Christine D; Powers, Christopher M
2011-10-01
The purpose of this study was to compare kicking biomechanics between young female soccer players at two different stages of physical maturation and to identify biomechanical predictors of peak foot velocity. Swing and stance limb kinematics and kinetics were recorded from 20 female soccer players (10 prepubertal, 10 postpubertal) while kicking a soccer ball using an angled two-step approach. Peak foot velocity as well as hip and knee kinematics and kinetics were compared between groups using independent-samples t-tests. Pearson correlation coefficients and stepwise multiple regression were used to identify predictors of peak foot velocity. Peak foot velocity and the peak swing limb net hip flexor moment was significantly greater in the postpubertal group when compared with the prepubertal group (13.4 vs 11.6 m·s(-1), P = 0.003; 1.22 vs 1.07 N·m·kg(-1)·m(-1), P = 0.03). Peak stance limb hip and knee extensor moments were not different between groups. Although the peak swing limb hip and knee flexion angles were similar between groups, the postpubertal group demonstrated significantly less peak stance limb hip and knee flexion angles when compared with the prepubertal group (P < 0.001 and P = 0.045). Using a linear regression model, swing limb peak hip flexor moment and peak swing limb hip extension range of motion combined to explain 65% of the variance in peak foot velocity. Despite a difference in stance limb kinematics, similar swing limb kinematics between groups indicates that the prepubertal female athletes kicked with a mature swing limb kick pattern. The ability to generate a large hip flexor moment of the swing limb seems to be an important factor for improving kicking performance in young female soccer players.
Shin, Choongsoo S; Carpenter, R Dana; Majumdar, Sharmila; Ma, C Benjamin
2009-11-01
The purpose of this study was to test whether (1) the 3-dimensional in vivo patellofemoral kinematics and patellofemoral contact area of anterior cruciate ligament (ACL)-deficient knees are different from those of normal, contralateral knees and (2) ACL reconstruction restores in vivo patellofemoral kinematics and contact area. Ten ACL-deficient knees and twelve ACL-reconstructed knees, as well as the contralateral uninjured knees, were tested. Magnetic resonance imaging was performed at full extension and 40 degrees of flexion under simulated partial weight-bearing conditions. Six-degrees of freedom patellofemoral kinematics, patellofemoral contact area, and contact location were analyzed by use of magnetic resonance image-based 3-dimensional patellofemoral knee models. The patella in the ACL-deficient knees underwent significantly more lateral tilt during flexion (P < .05) and tended to translate more laterally (P = .083) than the patella in contralateral knees. After ACL reconstruction, no kinematic parameters were significantly different from those in contralateral knees. The patellofemoral contact areas of ACL-deficient knees at both the extended and flexed positions (37 +/- 22 mm(2) and 357 +/- 53 mm(2), respectively) were significantly smaller than those of contralateral knees (78 +/- 45 mm(2) and 437 +/- 119 mm(2), respectively) (P < .05). After reconstruction, the patellofemoral contact area of ACL-reconstructed knees in the extended position (86 +/- 41 mm(2)) was significantly larger (P < .05) than that of contralateral knees (50 +/- 34 mm(2)), but no difference was detected in the flexed position. Reproducibility of all patellofemoral kinematic parameters, contact centroid translation, and contact area showed coefficients of variation of less than 6.8%. ACL injuries alter patellofemoral kinematics including patellar tilt and patellar lateral translation, but ACL reconstruction with hamstring or allograft restores altered patellar tilt. ACL injuries reduce the patellofemoral contact area at both the extended and flexed positions, but ACL reconstruction enlarges the patellofemoral contact area at extension and restores the normal contact area at low angles of flexion. Level III, case-control study.
Suganuma, Jun; Mochizuki, Ryuta; Inoue, Yutaka; Kitamura, Kazuya; Honda, Akio
2014-02-01
The aim of this study was to investigate the pathoanatomic features of patellar instability by arthroscopically comparing patellofemoral congruence with rotation of the knee joint and/or electrical stimulation of the quadriceps (ESQ) between knees with and without patellar instability. We retrospectively examined 83 knee joints in 83 patients. The joints were classified into 2 groups: group 1 comprised those without a history of patellar dislocation and included 59 patients (25 male and 34 female patients), and group 2 comprised those with a history of patellar dislocation and included 24 patients (9 male and 15 female patients). Evaluation of patellofemoral congruence at 30° of flexion of the knee joint was conducted based on an axial radiograph and arthroscopic findings. The congruence angle was measured on the radiograph. The position of the patellar central ridge (PPCR) on the trochlear groove during arthroscopy was measured using still video frames of knee joints with rotational stress and/or ESQ. Statistical differences in the measurements between the 2 groups were assessed with the unpaired t test and the area under the receiver operating characteristic curve of each measurement. There were significant differences (P < .0001) between the 2 groups in the congruence angle on radiographs and PPCR in knee joints with rotational stress and/or ESQ on arthroscopy. External and internal rotation of the knee joint caused lateral and medial patellar shift, respectively, in both groups, but the shift was significantly larger in group 2. ESQ in addition to rotation caused further patellar shift in group 2 but reduced patellar shift in group 1. Measurement of PPCR with external rotation of the knee and ESQ was the only method to show an area under the receiver operating characteristic curve of 1. There were significant differences in the effects of rotation of the knee joint and/or ESQ on patellofemoral congruence at 30° of flexion of the knee joint on arthroscopy between knees with and without patellar instability. Level III, diagnostic study of nonconsecutive patients. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Ünkar, Ethem Ayhan; Öztürkmen, Yusuf; Şükür, Erhan; Çarkçı, Engin; Mert, Murat
2017-03-01
The aim of this study was to compare the radiological and functional results of posterior cruciate ligament (PCL) - retaining and posterior-stabilized total knee arthroplasties in patients with severe varus gonarthrosis. Medical records of 112 knees of 96 patients who underwent total knee arthroplasty for severe varus (≥15°) were reviewed. PCL-retaining and PCL-stabilizing groups consisted of 58 and 54 knees, respectively. Mean follow-up time was 56.6 months (range: 24-112 months). Knee Society (KS) clinical rating system was used in clinical evaluation. Range of motion, degree of flexion contracture, postoperative alignment, and complication rates were compared between the groups. Mean preoperative mechanical tibiofemoral angle was 20.1° in varus alignment, and was restored to 4.6° in valgus postoperatively. No statistically significant differences were found between PCL-stabilizing and PCL-retaining groups when KS knee scores, function scores, and flexion arc were evaluated. Two patients in PCL-retaining group underwent revision surgery due to aseptic loosening of tibial component. One patient in PCL-stabilizing group needed arthrotomy due to patellar clunk syndrome. There were no notable differences between the 2 groups and PCL-retaining design had outcomes as good as PCL-stabilizing total knee implant in osteoarthritic knees with severe varus deformity. Level III, Therapeutic study. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.
Estimation of Quasi-Stiffness of the Human Knee in the Stance Phase of Walking
Shamaei, Kamran; Sawicki, Gregory S.; Dollar, Aaron M.
2013-01-01
Biomechanical data characterizing the quasi-stiffness of lower-limb joints during human locomotion is limited. Understanding joint stiffness is critical for evaluating gait function and designing devices such as prostheses and orthoses intended to emulate biological properties of human legs. The knee joint moment-angle relationship is approximately linear in the flexion and extension stages of stance, exhibiting nearly constant stiffnesses, known as the quasi-stiffnesses of each stage. Using a generalized inverse dynamics analysis approach, we identify the key independent variables needed to predict knee quasi-stiffness during walking, including gait speed, knee excursion, and subject height and weight. Then, based on the identified key variables, we used experimental walking data for 136 conditions (speeds of 0.75–2.63 m/s) across 14 subjects to obtain best fit linear regressions for a set of general models, which were further simplified for the optimal gait speed. We found R2 > 86% for the most general models of knee quasi-stiffnesses for the flexion and extension stages of stance. With only subject height and weight, we could predict knee quasi-stiffness for preferred walking speed with average error of 9% with only one outlier. These results provide a useful framework and foundation for selecting subject-specific stiffness for prosthetic and exoskeletal devices designed to emulate biological knee function during walking. PMID:23533662
Lesinski, Melanie; Prieske, Olaf; Borde, Ron; Beurskens, Rainer; Granacher, Urs
2018-04-13
Lesinski, M, Prieske, O, Borde, R, Beurskens, R, and Granacher, U. Effects of different footwear properties and surface instability on neuromuscular activity and kinematics during jumping. J Strength Cond Res XX(X): 000-000, 2018-The purpose of this study was to examine sex-specific effects of different footwear properties vs. barefoot condition during the performance of drop jumps (DJs) on stable and unstable surfaces on measures of jump performance, electromyographic (EMG) activity, and knee joint kinematics. Drop jump performance, EMG activity of lower-extremity muscles, as well as sagittal and frontal knee joint kinematics were tested in 28 healthy male (n = 14) and female (n = 14) physically active sports science students (23 ± 2 years) during the performance of DJs on stable and unstable surfaces using different footwear properties (elastic vs. minimal shoes) vs. barefoot condition. Analysis revealed a significantly lower jump height and performance index (Δ7-12%; p < 0.001; 2.22 ≤ d = 2.90) during DJs on unstable compared with stable surfaces. This was accompanied by lower thigh/shank muscle activities (Δ11-28%; p < 0.05; 0.99 ≤ d = 2.16) and knee flexion angles (Δ5-8%; p < 0.05; 1.02 ≤ d = 2.09). Furthermore, knee valgus angles during DJs were significantly lower when wearing shoes compared with barefoot condition (Δ22-32%; p < 0.01; 1.38 ≤ d = 3.31). Sex-specific analyses indicated higher knee flexion angles in females compared with males during DJs, irrespective of the examined surface and footwear conditions (Δ29%; p < 0.05; d = 0.92). Finally, hardly any significant footwear-surface interactions were detected. Our findings revealed that surface instability had an impact on DJ performance, thigh/shank muscle activity, and knee joint kinematics. In addition, the single factors "footwear" and "sex" modulated knee joint kinematics during DJs. However, hardly any significant interaction effects were found. Thus, additional footwear-related effects can be neglected when performing DJs during training on different surfaces.
Vignos, Michael F; Kaiser, Jarred M; Baer, Geoffrey S; Kijowski, Richard; Thelen, Darryl G
2018-05-10
Abnormal knee mechanics may contribute to early cartilage degeneration following anterior cruciate ligament reconstruction. Anterior cruciate ligament graft geometry has previously been linked to abnormal tibiofemoral kinematics, suggesting this parameter may be important in restoring normative cartilage loading. However, the relationship between graft geometry and cartilage contact is unknown. Static MR images were collected and segmented for eighteen subjects to obtain bone, cartilage, and anterior cruciate ligament geometries for their reconstructed and contralateral knees. The footprint locations and orientation of the anterior cruciate ligament were calculated. Volumetric, dynamic MR imaging was also performed to measure tibiofemoral kinematics, cartilage contact location, and contact sliding velocity while subjects performed loaded knee flexion-extension. Multiple linear regression was used to determine the relationship between non-anatomic graft geometry and asymmetric knee mechanics. Non-anatomic graft geometry was related to asymmetric knee mechanics, with the sagittal plane graft angle being the best predictor of asymmetry. A more vertical sagittal graft angle was associated with greater anterior tibial translation (β = 0.11mmdeg, P = 0.049, R 2 = 0.22), internal tibial rotation (β = 0.27degdeg, P = 0.042, R 2 = 0.23), and adduction angle (β = 0.15degdeg, P = 0.013, R 2 = 0.44) at peak knee flexion. A non-anatomic sagittal graft orientation was also linked to asymmetries in tibial contact location and sliding velocity on the medial (β = -4.2mmsdeg, P = 0.002, R 2 = 0.58) and lateral tibial plateaus (β = 5.7mmsdeg, P = 0.006, R 2 = 0.54). This study provides evidence that non-anatomic graft geometry is linked to asymmetric knee mechanics, suggesting that restoring native anterior cruciate ligament geometry may be important to mitigate the risk of early cartilage degeneration in these patients. Copyright © 2018 Elsevier Ltd. All rights reserved.
Williams, D S Blaise; Green, Douglas H; Wurzinger, Brian
2012-10-01
Both forefoot strike shod (FFS) and barefoot (BF) running styles result in different mechanics when compared to rearfoot strike (RFS) shod running. Additionally, running mechanics of FFS and BF running are similar to one another. Comparing the mechanical changes occurring in each of these patterns is necessary to understand potential benefits and risks of these running styles. The authors hypothesized that FFS and BF conditions would result in increased sagittal plane joint angles at initial contact and that FFS and BF conditions would demonstrate a shift in sagittal plane joint power from the knee to the ankle when compared to the RFS condition. Finally, total lower extremity power absorption will be least in BF and greatest in the RFS shod condition. The study included 10 male and 10 female RFS runners who completed 3-dimensional running analysis in 3 conditions: shod with RFS, shod with FFS, and BF. Variables were the angles of plantarflexion, knee flexion, and hip flexion at initial contact and peak sagittal plane joint power at the hip, knee, and ankle during stance phase. Running with a FFS pattern and BF resulted in significantly greater plantarflexion and significantly less negative knee power (absorption) when compared to shod RFS condition. FFS condition runners landed in the most plantarflexion and demonstrated the most peak ankle power absorption and lowest knee power absorption between the 3 conditions. BF and FFS conditions demonstrated decreased total lower extremity power absorption compared to the shod RFS condition but did not differ from one another. BF and FFS running result in reduced total lower extremity power, hip power and knee power and a shift of power absorption from the knee to the ankle. Alterations associated with BF running patterns are present in a FFS pattern when wearing shoes. Additionally, both patterns result in increased demand at the foot and ankle as compared to the knee.
Green, Douglas H.; Wurzinger, Brian
2012-01-01
Purpose/Background: Both forefoot strike shod (FFS) and barefoot (BF) running styles result in different mechanics when compared to rearfoot strike (RFS) shod running. Additionally, running mechanics of FFS and BF running are similar to one another. Comparing the mechanical changes occurring in each of these patterns is necessary to understand potential benefits and risks of these running styles. The authors hypothesized that FFS and BF conditions would result in increased sagittal plane joint angles at initial contact and that FFS and BF conditions would demonstrate a shift in sagittal plane joint power from the knee to the ankle when compared to the RFS condition. Finally, total lower extremity power absorption will be least in BF and greatest in the RFS shod condition. Methods: The study included 10 male and 10 female RFS runners who completed 3‐dimensional running analysis in 3 conditions: shod with RFS, shod with FFS, and BF. Variables were the angles of plantarflexion, knee flexion, and hip flexion at initial contact and peak sagittal plane joint power at the hip, knee, and ankle during stance phase. Results: Running with a FFS pattern and BF resulted in significantly greater plantarflexion and significantly less negative knee power (absorption) when compared to shod RFS condition. FFS condition runners landed in the most plantarflexion and demonstrated the most peak ankle power absorption and lowest knee power absorption between the 3 conditions. BF and FFS conditions demonstrated decreased total lower extremity power absorption compared to the shod RFS condition but did not differ from one another. Conclusions: BF and FFS running result in reduced total lower extremity power, hip power and knee power and a shift of power absorption from the knee to the ankle. Clinical Relevance: Alterations associated with BF running patterns are present in a FFS pattern when wearing shoes. Additionally, both patterns result in increased demand at the foot and ankle as compared to the knee. PMID:23091785
Selective recruitment of the triceps surae muscles with changes in knee angle.
Signorile, Joseph F; Applegate, Brooks; Duque, Maurice; Cole, Natalie; Zink, Attila
2002-08-01
The muscles of the triceps surae group are important for performance in most sports and in the performance of activities of daily life. In addition, hypertrophy and balance among these muscles are integral to success in bodybuilding. The purpose of this study was to compare the muscle utilization patterns of the 2 major muscles of the triceps surae group, the soleus (SOL) and gastrocnemius (lateral head = LG and medial head = MG), and the tibialis anterior (TA) as an antagonist muscle to the group. Their electromyographic (EMG) signals were compared during 50 constant external resistance contractions at a level established before the testing session. Eleven experienced subjects contributed data during plantar flexion at 3 different knee angles (90, 135, and 180 degrees ). Both root mean square amplitude and integrated signal analyses of the EMGs revealed that the MG produced significantly greater activity than either the SOL or TA at 180 degrees, whereas the LG was not different from the SOL at any knee angle measured. Data also revealed that the SOL produced less electrical activity at 180 degrees than at the other knee angles, whereas the MG produced greater electrical activity. As would be expected, the TA produced lower EMG values than any of the triceps surae muscles at all angles tested. These data indicate that selective targeting of the SOL and MG is possible through the manipulation of knee angle. This targeting appears to be controlled by the biarticular and monoarticular structures of the MG and SOL, respectively. The LG appears less affected by knee position than the MG. Results suggest that the SOL can be targeted most effectively with the knee flexed at 90 degrees and the MG with the leg fully extended. The LG appears to also be more active at 180 degrees; however, it is not as affected as the MG or SOL by knee angle.
Niki, Yasuo; Takeda, Yuki; Harato, Kengo; Suda, Yasunori
2015-11-01
Achievement of very deep knee flexion after total knee arthroplasty (TKA) can play a critical role in the satisfaction of patients who demand a floor-sitting lifestyle and engage in high-flexion daily activities (e.g., seiza-sitting). Seiza-sitting is characterized by the knees flexed >145º and feet turned sole upwards underneath the buttocks with the tibia internally rotated. The present study investigated factors affecting the achievement of seiza-sitting after TKA using posterior-stabilized total knee prosthesis with high-flex knee design. Subjects comprised 32 patients who underwent TKA with high-flex knee prosthesis and achieved seiza-sitting (knee flexion >145º) postoperatively. Another 32 patients served as controls who were capable of knee flexion >145º preoperatively, but failed to achieve seiza-sitting postoperatively. Accuracy of femoral and tibial component positions was assessed in terms of deviation from the ideal position using a two-dimensional to three-dimensional matching technique. Accuracies of the component position, posterior condylar offset ratio and intraoperative gap length were compared between the two groups. The proportion of patients with >3º internally rotated tibial component was significantly higher in patients who failed at seiza-sitting (41 %) than among patients who achieved it (13 %, p = 0.021). Comparison of intraoperative gap length between patient groups revealed that gap length at 135º flexion was significantly larger in patients who achieved seiza-sitting (4.2 ± 0.4 mm) than in patients who failed at it (2.7 ± 0.4 mm, p = 0.007). Conversely, no significant differences in gap inclination were seen between the groups. From the perspective of surgical factors, accurate implant positioning, particularly rotational alignment of the tibial component, and maintenance of a sufficient joint gap at 135º flexion appear to represent critical factors for achieving >145º of deep knee flexion after TKA.
Hip and knee effects after implantation of a drop foot stimulator.
Yao, Daiwei; Lahner, Matthias; Jakubowitz, Eike; Thomann, Anna; Ettinger, Sarah; Noll, Yvonne; Stukenborg-Colsman, Christina; Daniilidis, Kiriakos
2017-01-01
An active ankle dorsiflexion is essential for a proper gait pattern. If there is a failure of the foot lifting, considerable impairments occur. The therapeutic effect of an implantable peroneus nerve stimulator (iPNS) for the ankle dorsiflexion is already approved by recent studies. However, possible affection for knee and hip motion after implantation of an iPNS is not well described. The objective of this retrospective study was to examine with a patient cohort whether the use of iPNS induces a lower-extremity flexion withdrawal response in the form of an increased knee and hip flexion during swing phase. Eighteen subjects (12 m/6 w) treated with an iPNS (ActiGait®, Otto Bock, Duderstadt, Germany) were examined in knee and hip motion by gait analysis with motion capture system (Vicon Motion System Ltd®, Oxford, UK) and Plug-in-Gait model after a mean follow up from 12.5 months. The data were evaluated and compared in activated and deactivated iPNS. Only little changes could be documented, as a slight average improvement in peak knee flexion during stand phase from 1.0° to 2.5° and peak hip flexion in stance from 3.1° to 2.1° In contrast, peak knee flexion during swing appeared similar (25.3° to 25.7°) same as peak hip flexion during swing. In comparison with the healthy extremity, a more symmetric course of the knee flexion during stand phase could be shown. No statistical significant improvements or changes in hip and knee joint could be shown in this study. Only a more symmetric knee flexion during stand phase and a less hip flexion during stand phase might be hints for a positive affection of iPNS for knee and hip joint. It seems that the positive effect of iPNS is only based on the improvement in ankle dorsiflexion according to the recent literature.
Drew, B T; Redmond, A C; Smith, T O; Penny, F; Conaghan, P G
2016-02-01
To review the association between patellofemoral joint (PFJ) imaging features and patellofemoral pain (PFP). A systematic review of the literature from AMED, CiNAHL, Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, PEDro, EMBASE and SPORTDiscus was undertaken from their inception to September 2014. Studies were eligible if they used magnetic resonance imaging (MRI), computed tomography (CT), ultrasound (US) or X-ray (XR) to compare PFJ features between a PFP group and an asymptomatic control group in people <45 years of age. A pooled meta-analysis was conducted and data was interpreted using a best evidence synthesis. Forty studies (all moderate to high quality) describing 1043 people with PFP and 839 controls were included. Two features were deemed to have a large standardised mean difference (SMD) based on meta-analysis: an increased MRI bisect offset at 0° knee flexion under load (0.99; 95% CI: 0.49, 1.49) and an increased CT congruence angle at 15° knee flexion, both under load (1.40 95% CI: 0.04, 2.76) and without load (1.24; 95% CI: 0.37, 2.12). A medium SMD was identified for MRI patella tilt and patellofemoral contact area. Limited evidence was found to support the association of other imaging features with PFP. A sensitivity analysis showed an increase in the SMD for patella bisect offset at 0° knee flexion (1.91; 95% CI: 1.31, 2.52) and patella tilt at 0° knee flexion (0.99; 95% CI: 0.47, 1.52) under full weight bearing. Certain PFJ imaging features were associated with PFP. Future interventional strategies may be targeted at these features. CRD 42014009503. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Profiling Isokinetic Strength by Leg Preference and Position in Rugby Union Athletes.
Brown, Scott R; Brughelli, Matt; Bridgeman, Lee A
2016-05-01
Muscle imbalances aid in the identification of athletes at risk for lower-extremity injury. Little is known regarding the influence that leg preference or playing position may have on lower-extremity muscle strength and asymmetry. To investigate lower-extremity strength profiles in rugby union athletes and compare isokinetic knee- and hip-strength variables between legs and positions. Thirty male academy rugby union athletes, separated into forwards (n = 15) and backs (n = 15), participated in this cross-sectional analysis. Isokinetic dynamometry was used to evaluate peak torque, angle of peak torque, and strength ratios of the preferred and nonpreferred legs during seated knee extension/flexion and supine hip extension/flexion at 60°/s. Backs were older (ES = 1.6) but smaller in stature (ES = -0.47) and body mass (ES = -1.3) than the forwards. The nonpreferred leg was weaker than the preferred leg for forwards during extension (ES = -0.37) and flexion (ES = -0.21) actions and for backs during extension (ES = -0.28) actions. Backs were weaker at the knee than forwards in the preferred leg during extension (ES = -0.50) and flexion (ES = -0.66) actions. No differences were observed in strength ratios between legs or positions. Backs produced peak torque at longer muscle lengths in both legs at the knee (ES = -0.93 to -0.94) and hip (ES = -0.84 to -1.17) than the forwards. In this sample of male academy rugby union athletes, the preferred leg and forwards displayed superior strength compared with the nonpreferred leg and backs. These findings highlight the importance of individualized athletic assessments to detect crucial strength differences in male rugby union athletes.
Koshino, Yuta; Yamanaka, Masanori; Ezawa, Yuya; Ishida, Tomoya; Kobayashi, Takumi; Samukawa, Mina; Saito, Hiroshi; Takeda, Naoki
2014-11-01
To compare the kinematics of lower limb joints between individuals with and without chronic ankle instability (CAI) during cross-turn and -cutting movements. Cross-sectional study. Motion analysis laboratory. Twelve subjects with CAI and twelve healthy controls. Hip flexion, adduction, and internal rotation, knee flexion, and ankle dorsiflexion and inversion angles were calculated in the 200 ms before initial ground contact and from initial ground contact to toe-off (stance phase) in a cross-turn movement during gait and a cross-cutting movement from a forward jump, and compared across the two groups. In the cross-cutting movement, the CAI group exhibited greater hip and knee flexion than the control group during the stance phase, and more hip abduction during the period before initial contact and the stance phase. In the cross-turn movement the joint kinematics were similar in the two groups. CAI subjects exhibited an altered pattern of the proximal joint kinematics during a cross-cutting movement. It is important for clinicians to assess the function of the hip and knee as well as the ankle, and to incorporate coordination training for the entire lower limb into rehabilitation after lateral ankle sprains. Copyright © 2013 Elsevier Ltd. All rights reserved.
Louw, Maryke; Deary, Clare
2014-02-01
The aim of this literature review was to identify the biomechanical variables involved in the aetiology of iliotibial band syndrome (ITBS) in distance runners. An electronic search was conducted using the terms "iliotibial band" and "iliotibial tract". The results showed that runners with a history of ITBS appear to display decreased rear foot eversion, tibial internal rotation and hip adduction angles at heel strike while having greater maximum internal rotation angles at the knee and decreased total abduction and adduction range of motion at the hip during stance phase. They further appear to experience greater invertor moments at their feet, decreased abduction and flexion velocities at their hips and to reach maximum hip flexion angles earlier than healthy controls. Maximum normalised braking forces seem to be decreased in these athletes. The literature is inconclusive with regards to muscle strength deficits in runners with a history of ITBS. Prospective research suggested that greater internal rotation at the knee joint and increased adduction angles of the hip may play a role in the aetiology of ITBS and that the strain rate in the iliotibial bands of these runners may be increased compared to healthy controls. A clear biomechanical cause for ITBS could not be devised due to the lack of prospective research. Copyright © 2013 Elsevier Ltd. All rights reserved.
Multi-Axis Prosthetic Knee Resembles Alpine Skiing Movements of an Intact Leg
Demšar, Ivan; Duhovnik, Jože; Lešnik, Blaž; Supej, Matej
2015-01-01
The purpose of the study was to analyse the flexion angles of the ski boot, ankle and knee joints of an above-knee prosthesis and to compare them with an intact leg and a control group of skiers. One subject with an above-knee amputation of the right leg and eight healthy subjects simulated the movement of a skiing turn by performing two-leg squats in laboratory conditions. By adding additional loads in proportion to body weight (BW; +1/3 BW, +2/3 BW, +3/3 BW), various skiing regimes were simulated. Change of Flexion Angle (CoFA) and Range of Motion (RoM) in the ski boot, ankle and knee joints were calculated and compared. An average RoM in the skiing boot on the side of prosthesis (4.4 ± 1.1°) was significantly lower compared to an intact leg (5.9 ± 1.8°) and the control group (6.5 ± 2.3°). In the ankle joint, the average RoM was determined to be 13.2±2.9° in the prosthesis, 12.7 ± 2.8° in an intact leg and 14.8±3.6 in the control group. However, the RoM of the knee joint in the prosthesis (42.2 ± 4.2°) was significantly larger than that of the intact leg (34.7 ± 4.4°). The average RoM of the knee joint in the control group was 47.8 ± 5.4°. The influences of additional loads on the kinematics of the lower extremities were different on the side of the prosthesis and on the intact leg. In contrast, additional loads did not produce any significant differences in the control group. Although different CoFAs in the ski boot, ankle and knee joints were used, an above-knee prosthesis with a built-in multi-axis prosthetic knee enables comparable leg kinematics in simulated alpine skiing. Key points The RoM in the ski boot on the side of the prosthetic leg was smaller than the RoM of the intact leg and the control group of healthy subjects. The RoM in the ankle joint of prosthetic leg was comparable to that of the intact leg and the control group of healthy subjects. The RoM in the prosthetic knee joint was greater than the RoM in the knee joint of the intact leg and smaller than that of the control group. The total knee flexions in the laboratory measurements were comparable with field measurements. Additional load affects the RoM of the ski boot, ankle and knee joints for the amputated skier in both legs. No significant influence from the additional load was found on the RoM in the control group of healthy subjects. The above-knee prosthesis with a multiple-axis prosthetic knee reproduces the alpine skiing kinematics of an intact leg. PMID:26664282
Ballistic movements of jumping legs implemented as variable components of cricket behaviour.
Hustert, R; Baldus, M
2010-12-01
Ballistic accelerations of a limb or the whole body require special joint mechanisms in many animals. Specialized joints can be moved by stereotypic or variable motor control during motor patterns with and without ballistic components. As a model of variable motor control, the specialized femur-tibia (knee) joints of cricket (Acheta domesticus) hindlegs were studied during ballistic kicking, jumping and swimming and in non-ballistic walking. In this joint the tendons of the antagonistic flexor and the extensor muscles attach at different distances from the pivot and the opposed lever arms form an angle of 120 deg. A 10:1 ratio of their effective lever arms at full knee flexion helps to prepare for most ballistic extensions: the tension of the extensor can reach its peak while it is restrained by flexor co-contraction. In kicks, preparatory flexion is rapid and the co-contraction terminates just before knee extensions. Therefore, mainly the stored tension of the extensor muscle accelerates the small mass of the tibia. Jumps are prepared with slower extensor-flexor co-contractions that flex both knees simultaneously and then halt to rotate both legs outward to a near horizontal level. From there, catapult extension of both knees accelerates the body, supported by continued high frequency motor activity to their tibia extensor muscles during the ongoing push-off from the substrate. Premature extension of one knee instantly takes load from the lagging leg that extends and catches up, which finally results in a straight jump. In swimming, synchronous ballistic power strokes of both hindlegs drive the tibiae on a ventral-to-posterior trajectory through the water, well coordinated with the swimming patterns of all legs. In walking, running and climbing the steps of the hindlegs range between 45 deg flexion and 125 deg extension and use non-ballistic, alternating activity of knee flexor and extensor muscles. Steep climbing requires longer bursts from the extensor tibiae muscles when they support the extended hindlegs against gravity forces when the body hangs over. All ballistic movements of cricket knees are elicited by a basic but variable motor pattern: knee flexions by co-contraction of the antagonists prepare catapult extensions with speeds and forces as required in the different behaviours.
Koutras, Georgios; Bernard, Manfred; Terzidis, Ioannis P; Papadopoulos, Pericles; Georgoulis, Anastasios; Pappas, Evangelos
2016-07-01
Hamstrings grafts are commonly used in ACL reconstruction, however, the effect of graft harvesting on knee flexion strength has not been longitudinally evaluated in functional positions. We hypothesized that greater deficits in knee flexion strength exist in the prone compared to the seated position and these deficits remain as rehabilitation progresses. Case series. Forty-two consecutive patients who underwent ACL reconstruction with a hamstrings graft were followed prospectively for 9 months. Isokinetic knee flexion strength at a slow and a fast speed were collected at 3, 4, 6, and 9 months in two different positions: conventional (seated) and functional (0° of hip flexion). Peak torque knee flexion deficits were higher in the prone position compared to the seated position by an average of 6.5% at 60°/s and 9.1% at 180°/s (p<0.001). Measuring knee flexion strength in prone demonstrates higher deficits than in the conventional seated position. Most athletes would not be cleared to return to sports even at 9 months after surgery with this method. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Shimokochi, Yohei; Ambegaonkar, Jatin P.; Meyer, Eric G.
2016-01-01
Context: Ground reaction force (GRF) and tibiofemoral force magnitudes and directions have been shown to affect anterior cruciate ligament loading during landing. However, the kinematic and kinetic factors modifying these 2 forces during landing are unknown. Objective: To clarify the intersegmental kinematic and kinetic links underlying the alteration of the GRF and tibiofemoral force vectors secondary to changes in the sagittal-plane body position during single-legged landing. Design: Crossover study. Setting: Laboratory. Patients or Other Participants: Twenty recreationally active participants (age = 23.4 ± 3.6 years, height = 171.0 ± 9.4 cm, mass = 73.3 ± 12.7 kg). Intervention(s): Participants performed single-legged landings using 3 landing styles: self-selected landing (SSL), body leaning forward and landing on the toes (LFL), and body upright with flat-footed landing (URL). Three-dimensional kinetics and kinematics were recorded. Main Outcome Measure(s): Sagittal-plane tibial inclination and knee-flexion angles, GRF magnitude and inclination angles relative to the tibia, and proximal tibial forces at peak tibial axial forces. Results: The URL resulted in less time to peak tibial axial forces, smaller knee-flexion angles, and greater magnitude and a more anteriorly inclined GRF vector relative to the tibia than did the SSL. These changes led to the greatest peak tibial axial and anterior shear forces in the URL among the 3 landing styles. Conversely, the LFL resulted in longer time to peak tibial axial forces, greater knee-flexion angles, and reduced magnitude and a more posteriorly inclined GRF vector relative to the tibia than the SSL. These changes in LFL resulted in the lowest peak tibial axial and largest posterior shear forces among the 3 landing styles. Conclusions: Sagittal-plane intersegmental kinematic and kinetic links strongly affected the magnitude and direction of GRF and tibiofemoral forces during the impact phase of single-legged landing. Therefore, improving sagittal-plane landing mechanics is important in reducing harmful magnitudes and directions of impact forces on the anterior cruciate ligament. PMID:27723362
Calibration of EMG to force for knee muscles is applicable with submaximal voluntary contractions.
Doorenbosch, Caroline A M; Joosten, Annemiek; Harlaar, Jaap
2005-08-01
In this study, the influence of using submaximal isokinetic contractions about the knee compared to maximal voluntary contractions as input to obtain the calibration of an EMG-force model for knee muscles is investigated. Isokinetic knee flexion and extension contractions were performed by healthy subjects at five different velocities and at three contraction levels (100%, 75% and 50% of MVC). Joint angle, angular velocity, joint moment and surface EMG of five knee muscles were recorded. Individual calibration values were calculated according to [C.A.M. Doorenbosch, J. Harlaar, A clinically applicable EMG-force model to quantify active stabilization of the knee after a lesion of the anterior cruciate ligament, Clinical Biomechanics 18 (2003) 142-149] for each contraction level. First, the output of the model, calibrated with the 100% MVC was compared to the actually exerted net knee moment at the dynamometer. Normalized root mean square errors were calculated [A.L. Hof, C.A.N. Pronk, J.A. van Best, Comparison between EMG to force processing and kinetic analysis for the calf muscle moment in walking and stepping, Journal of Biomechanics 20 (1987) 167-187] to compare the estimated moments with the actually exerted moments. Mean RMSD errors ranged from 0.06 to 0.21 for extension and from 0.12 to 0.29 for flexion at the 100% trials. Subsequently, the calibration results of the 50% and 75% MVC calibration procedures were used. A standard signal, representing a random EMG level was used as input in the EMG force model, to compare the three models. Paired samples t-tests between the 100% MVC and the 75% MVC and 50% MVC, respectively, showed no significant differences (p>0.05). The application of submaximal contractions of larger than 50% MVC is suitable to calibrate a simple EMG to force model for knee extension and flexion. This means that in clinical practice, the EMG to force model can be applied by patients who cannot exert maximal force.
Yamazaki, J; Muneta, T; Ju, Y J; Sekiya, I
2010-01-01
Seventy to eighty percent of all anterior cruciate ligament (ACL) injuries are due to non-contact injury mechanisms. It has been reported that the majority of injuries due to single leg landing come from valgus positioning of the lower leg. Preventing valgus positioning during single leg landing is expected to help reduce the number of ACL injuries. We found that many ACL-deficient patients cannot perform stable single leg squatting. Therefore, we performed 3D motion analysis of the single-legged half squat for ACL-injured patients to evaluate its significance as a risk factor for ACL injuries. We evaluated the relative angles between the body, thigh, and lower leg using an electromagnetic device during single leg half squatting performed by 63 ACL-injured patients (32 males, 31 females) the day before ACL reconstruction and by 26 healthy control subjects with no knee problems. The uninjured leg of ACL-injured male subjects demonstrated significantly less external knee rotation than that of the dominant leg of the male control. The uninjured leg of ACL-injured female subjects demonstrated significantly more external hip rotation and knee flexion and less hip flexion than that of the dominant leg of the female control. Comparing injured and uninjured legs, the injured leg of male subjects demonstrated significantly less external knee and hip rotation, less knee flexion, and more knee varus than that of the uninjured leg of male subjects. The injured leg of female subjects demonstrated more knee varus than that of the uninjured leg of female subjects. Regarding gender differences, female subjects demonstrated significantly more external hip rotation and knee valgus than male subjects did in both the injured and uninjured legs (P < 0.05). The current kinematic study exhibited biomechanical characteristics of female ACL-injured subjects compared with that of control groups. Kinematic correction during single leg half squat would reduce ACL reinjury in female ACL-injured subjects.
The effect of minimalist footwear and instruction on running: an observational study
Buckley, Linda; Palmer, Lisa J M; Ormond, Roisin M; Owen, Gwawr; Watson, Daniel J; Woledge, Roger; Newham, Di
2017-01-01
Background It is not known whether the effects on altered running style which are attributed to minimalist footwear can be achieved by verbal instructions in standard running shoes (SRS). Aim To explore the effect of Vibram FiveFingers (VFF) versus SRS plus running instruction on lower extremity spatiotemporal parameters and lower limb joint kinematics. Methods 35 healthy subjects (mean=30 years, 18 females) were assessed on two occasions with 3D motion analysis. At each session subjects ran on a treadmill (3.58 m/s) for 2 min in either VFF or SRS (randomised order); with and without running instruction. Differences between spatiotemporal parameters and lower limb joint kinematics between conditions were assessed using a 2x2 repeated-measures ANOVA. Results Wearing VFF significantly increased cadence (p<0.001) and reduced stride length (p<0.01). Prior to initial contact, both instruction and VFF significantly increased foot (p<0.001 and p=0.02, respectively) and ankle (p<0.001 and p=0.02, respectively) plantarflexion, while wearing VFF significantly increased knee extension (p=0.04). At initial contact, instruction significantly increased knee flexion (p=0.04), and foot (p=0.001) and ankle (p=0.03) plantarflexion. At mid-stance and toe-off, instruction significantly increased knee flexion (p=0.048 and p<0.001, respectively) and foot plantarflexion (p<0.001 and p=0.01, respectively). Instruction had a greater effect on increasing knee flexion (p=0.007) and plantarflexion angle (p<0.001) when subjects wore SRS and VFF, respectively. Conclusion Alterations in spatiotemporal parameters observed when running in VFF are likely to be attributable to the minimalist footwear. However, the kinematic adaptations observed following instruction suggests that changes in joint angles previously attributed to minimalist footwear alone may be similarly achieved with instruction. PMID:28761694
Effects of general principles of person transfer techniques on low back joint extension moment.
Katsuhira, Junji; Yamasaki, Syun; Yamamoto, Sumiko; Maruyama, Hitoshi
2010-01-01
The purpose of this study was to examine the effects of general principles of person transfer techniques specifically on the low back joint extension moment. These effects were examined by the following measurable quantitative parameters: 1) trunk bending angle, 2) knee flexion angle, 3) distance between the centers of gravity (COGs) of the caregiver and patient, representing the distance between the caregiver and patient, and 4) the vertical component of the ground reaction force representing the amount of the weight-bearing load on the caregiver's low back during transfers with and without assistive devices. Twenty students each took the role of caregiver, and one healthy adult simulated a patient. The participants performed three different transfer tasks: without any assistive device, with the patient wearing a low back belt, and with the caregiver using a transfer board. We found that the distance between the COGs and the vertical component of the ground reaction force, but not the trunk bending and knee flexion angles, were the variables that affected the low back joint extension moment. Our results suggest that the general principle of decreasing the distance between COGs is most effective for decreasing the low back joint extension moment during transfers under all conditions.
Changes in lower extremity biomechanics due to a short-term fatigue protocol.
Cortes, Nelson; Greska, Eric; Kollock, Roger; Ambegaonkar, Jatin; Onate, James A
2013-01-01
Noncontact anterior cruciate ligament injury has been reported to occur during the later stages of a game when fatigue is most likely present. Few researchers have focused on progressive changes in lower extremity biomechanics that occur throughout fatiguing. To evaluate the effects of a sequential fatigue protocol on lower extremity biomechanics during a sidestep-cutting task (SS). Controlled laboratory study. Laboratory. Eighteen uninjured female collegiate soccer players (age = 19.2 ± 0.9 years, height = 1.66 ± 0.5 m, mass = 61.6 ± 5.1 kg) volunteered. The independent variable was fatigue level, with 3 levels (prefatigue, 50% fatigue, and 100% fatigue). Using 3-dimensional motion capture, we assessed lower extremity biomechanics during the SS. Participants alternated between a fatigue protocol that solicited different muscle groups and mimicked actual sport situations and unanticipated SS trials. The process was repeated until fatigue was attained. Dependent variables were hip- and knee-flexion and abduction angles and internal moments measured at initial contact and peak stance and defined as measures obtained between 0% and 50% of stance phase. Knee-flexion angle decreased from prefatigue (-17° ± 5°) to 50% fatigue (-16° ± 6°) and to 100% fatigue (-14° ± 4°) (F2,34 = 5.112, P = .004). Knee flexion at peak stance increased from prefatigue (-52.9° ± 5.6°) to 50% fatigue (-56.1° ± 7.2°) but decreased from 50% to 100% fatigue (-50.5° ± 7.1°) (F2,34 = 8.282, P = 001). Knee-adduction moment at peak stance increased from prefatigue (0.49 ± 0.23 Nm/kgm) to 50% fatigue (0.55 ± 0.25 Nm/kgm) but decreased from 50% to 100% fatigue (0.37 ± 0.24) (F2,34 = 3.755, P = 03). Hip-flexion angle increased from prefatigue (45.4° ± 10.9°) to 50% fatigue (46.2° ± 11.2°) but decreased from 50% to 100% fatigue (40.9° ± 11.3°) (F2,34 = 6.542, P = .004). Hip flexion at peak stance increased from prefatigue (49.8° ± 9.9°) to 50% fatigue (52.9° ± 12.1°) but decreased from 50% to 100% fatigue (46.3° ± 12.9°) (F2,34 = 8.639, P = 001). Hip-abduction angle at initial contact decreased from prefatigue (-13.8° ± 6.6°) to 50% fatigue (-9.1° ± 6.5°) and to 100% fatigue (-7.8° ± 6.5°) (F2,34 = 11.228, P < .001). Hip-adduction moment decreased from prefatigue (0.14 ± 0.13 Nm/kgm) to 50% fatigue (0.08 ± 0.13 Nm/kgm) and to 100% fatigue (0.06 ± 0.05 Nm/kg) (F2,34 = 5.767, P = .007). The detrimental effects of fatigue on sagittal and frontal mechanics of the hip and knee were visible at 50% of the participants' maximal fatigue and became more marked at 100% fatigue. Anterior cruciate ligament injury-prevention programs should emphasize feedback on proper mechanics throughout an entire practice and not only at the beginning of practice.
Changes in Lower Extremity Biomechanics Due to a Short-Term Fatigue Protocol
Cortes, Nelson; Greska, Eric; Kollock, Roger; Ambegaonkar, Jatin; Onate, James A.
2013-01-01
Context: Noncontact anterior cruciate ligament injury has been reported to occur during the later stages of a game when fatigue is most likely present. Few researchers have focused on progressive changes in lower extremity biomechanics that occur throughout fatiguing. Objective: To evaluate the effects of a sequential fatigue protocol on lower extremity biomechanics during a sidestep-cutting task (SS). Design: Controlled laboratory study. Setting: Laboratory. Patients or Other Participants: Eighteen uninjured female collegiate soccer players (age = 19.2 ± 0.9 years, height = 1.66 ± 0.5 m, mass = 61.6 ± 5.1 kg) volunteered. Intervention(s): The independent variable was fatigue level, with 3 levels (prefatigue, 50% fatigue, and 100% fatigue). Using 3-dimensional motion capture, we assessed lower extremity biomechanics during the SS. Participants alternated between a fatigue protocol that solicited different muscle groups and mimicked actual sport situations and unanticipated SS trials. The process was repeated until fatigue was attained. Main Outcome Measure(s): Dependent variables were hip- and knee-flexion and abduction angles and internal moments measured at initial contact and peak stance and defined as measures obtained between 0% and 50% of stance phase. Results: Knee-flexion angle decreased from prefatigue (−17° ± 5°) to 50% fatigue (−16° ± 6°) and to 100% fatigue (−14° ± 4°) (F2,34 = 5.112, P = .004). Knee flexion at peak stance increased from prefatigue (−52.9° ± 5.6°) to 50% fatigue (−56.1° ± 7.2°) but decreased from 50% to 100% fatigue (−50.5° ± 7.1°) (F2,34 = 8.282, P = 001). Knee-adduction moment at peak stance increased from prefatigue (0.49 ± 0.23 Nm/kgm) to 50% fatigue (0.55 ± 0.25 Nm/kgm) but decreased from 50% to 100% fatigue (0.37 ± 0.24) (F2,34 = 3.755, P = 03). Hip-flexion angle increased from prefatigue (45.4° ± 10.9°) to 50% fatigue (46.2° ± 11.2°) but decreased from 50% to 100% fatigue (40.9° ± 11.3°) (F2,34 = 6.542, P = .004). Hip flexion at peak stance increased from prefatigue (49.8° ± 9.9°) to 50% fatigue (52.9° ± 12.1°) but decreased from 50% to 100% fatigue (46.3° ± 12.9°) (F2,34 = 8.639, P = 001). Hip-abduction angle at initial contact decreased from prefatigue (−13.8° ± 6.6°) to 50% fatigue (−9.1° ± 6.5°) and to 100% fatigue (−7.8° ± 6.5°) (F2,34 = 11.228, P < .001). Hip-adduction moment decreased from prefatigue (0.14 ± 0.13 Nm/kgm) to 50% fatigue (0.08 ± 0.13 Nm/kgm) and to 100% fatigue (0.06 ± 0.05 Nm/kg) (F2,34 = 5.767, P = .007). Conclusions: The detrimental effects of fatigue on sagittal and frontal mechanics of the hip and knee were visible at 50% of the participants' maximal fatigue and became more marked at 100% fatigue. Anterior cruciate ligament injury-prevention programs should emphasize feedback on proper mechanics throughout an entire practice and not only at the beginning of practice. PMID:23675789
[Research progress of larger flexion gap than extension gap in total knee arthroplasty].
Zhang, Weisong; Hao, Dingjun
2017-05-01
To summarize the progress of larger flexion gap than extension gap in total knee arthro-plasty (TKA). The domestic and foreign related literature about larger flexion gap than extension gap in TKA, and its impact factors, biomechanical and kinematic features, and clinical results were summarized. During TKA, to adjust the relations of flexion gap and extension gap is one of the key factors of successful operation. The biomechanical, kinematic, and clinical researches show that properly larger flexion gap than extension gap can improve both the postoperative knee range of motion and the satisfaction of patients, but does not affect the stability of the knee joint. However, there are also contrary findings. So adjustment of flexion gap and extension gap during TKA is still in dispute. Larger flexion gap than extension gap in TKA is a new joint space theory, and long-term clinical efficacy, operation skills, and related complications still need further study.
Eliminating impingement optimizes patellar biomechanics in high knee flexion.
Tang, Qi-heng; Zhou, Yi-xin; Tang, Jing; Shao, Hong-yi; Wang, Guang-zhi
2010-08-01
We investigated the impact of eliminating the impingement between extensor mechanism and tibial insert on patellar tracking and patellar ligament tension in high knee flexion. Six cadaveric specimens were tested on an Oxford-type testing rig. The Genesis II knee system was implanted into each specimen knee with the traditional tibial insert and high-flex insert successively. Compared to traditional insert, the high-flex insert was characterized with a chambered anterior post and a chambered anterior lip which eliminates patella-post and patellar ligament-anterior lip impingements. The patella was tracked with an NDI Optotrak Certus system. The patellar ligament tension was measured using a NKB S-type tension transducer. There was a decrease of resultant patellar translation relative to the femur with statistically significant (P<0.05) at 90 degrees to 150 degrees of knee flexion and a decrease of patellar ligament tension with statistical significance (P<0.05) at 100 degrees, 120 degrees, 130 degrees, and 140 degrees of flexion using high-flex insert compared to traditional insert. Eliminating the impingement between extensor mechanism and implant in high knee flexion altered patellar tracking and reduced patellar ligament tension, which would facilitate high knee flexion.
Knee arthrodesis using an intramedullary nail.
Crockarell, John R; Mihalko, Marc J
2005-09-01
Fifteen knee arthrodeses using an intramedullary nail were performed in 15 patients. Indications included 11 failed total knee arthroplasties (10 of 11 septic). A retrospective review revealed 100% fusion rate. Complications included 4 cases of painful hardware, 1 trochanteric bursitis, and 1 deep infection. Ten patients were available for assessment at 7 years follow-up. Average leg length discrepancy was 3.7 cm. Anatomic axis averaged 1.3 degrees valgus. Flexion angle averaged 3.5 degrees . Compared with age-matched controls, our patients fared significantly worse in physical functioning, physical role, bodily pain, vitality, and social functioning. Arthrodesis of the knee with an intramedullary nail provides a reliable means of fusion with reasonable alignment. These patients have high rates of pain and diminished functional status.
Paterson, K L; Sosdian, L; Hinman, R S; Wrigley, T V; Kasza, J; Dowsey, M; Choong, P; Bennell, K L
2017-11-01
Sex and body mass may influence knee biomechanics associated with poor total knee arthroplasty (TKA) outcomes for knee osteoarthritis (OA). This study aimed to determine if gait differed between men and women, and overweight and class I obese patients with severe knee OA awaiting TKA. 34 patients with severe knee OA (average age 70.0 (SD 7.2) years, body mass index 30.3 (4.1kg/m 2 )) were recruited from a TKA waiting list. Three-dimensional gait analysis was performed at self-selected walking speed. Comparisons were made between men and women, and overweight (body mass index (BMI) 25.0-29.9kg/m 2 ) and class I obese (BMI 30.0-34.9kg/m 2 ) participants. Biomechanical outcomes included absolute and body size-adjusted peak knee adduction moment (KAM), KAM impulse, peak knee flexion moment, as well as peak knee flexion and varus-valgus angles, peak varus-valgus thrust, and peak vertical ground reaction force (GRF). Men had a higher absolute peak KAM, KAM impulse and peak GRF compared to women, and this sex-difference in frontal plane moments remained after adjusting for body size. However, when additionally adjusting for static knee alignment, differences disappeared. Knee biomechanics were similar between obesity groups after adjusting for the greater body weight of those with class I obesity. Men had greater KAM and KAM impulse even after adjustment for body size; however adjustment for their more varus knees removed this difference. Obesity group did not influence knee joint kinematics or moments. This suggests sex- and obesity-differences in these variables may not be associated with TKA outcomes. Copyright © 2017 Elsevier Ltd. All rights reserved.
Compressive tibiofemoral force during crouch gait.
Steele, Katherine M; Demers, Matthew S; Schwartz, Michael H; Delp, Scott L
2012-04-01
Crouch gait, a common walking pattern in individuals with cerebral palsy, is characterized by excessive flexion of the hip and knee. Many subjects with crouch gait experience knee pain, perhaps because of elevated muscle forces and joint loading. The goal of this study was to examine how muscle forces and compressive tibiofemoral force change with the increasing knee flexion associated with crouch gait. Muscle forces and tibiofemoral force were estimated for three unimpaired children and nine children with cerebral palsy who walked with varying degrees of knee flexion. We scaled a generic musculoskeletal model to each subject and used the model to estimate muscle forces and compressive tibiofemoral forces during walking. Mild crouch gait (minimum knee flexion 20-35°) produced a peak compressive tibiofemoral force similar to unimpaired walking; however, severe crouch gait (minimum knee flexion>50°) increased the peak force to greater than 6 times body-weight, more than double the load experienced during unimpaired gait. This increase in compressive tibiofemoral force was primarily due to increases in quadriceps force during crouch gait, which increased quadratically with average stance phase knee flexion (i.e., crouch severity). Increased quadriceps force contributes to larger tibiofemoral and patellofemoral loading which may contribute to knee pain in individuals with crouch gait. Copyright © 2011 Elsevier B.V. All rights reserved.
Hamstring Strength and Morphology Progression after Return to Sport from Injury
Sanfilippo, Jennifer; Silder, Amy; Sherry, Marc A; Tuite, Michael J; Heiderscheit, Bryan C
2012-01-01
Hamstring strain re-injury rates can reach 30% within the initial two weeks following return to sport (RTS). Incomplete recovery of strength may be a contributing factor. However, relative strength of the injured and unaffected limbs at RTS is currently unknown. PURPOSE: Characterize hamstring strength and morphology at the time of RTS and six months later. METHODS: Twenty-five athletes that experienced an acute hamstring strain injury participated, following completion of a controlled rehabilitation program. Bilateral isokinetic strength testing and magnetic resonance imaging (MRI) were performed at RTS and 6-months later. Strength (knee flexion peak torque, work, angle of peak torque) and MRI (muscle and tendon volumes) measures were compared between limbs and over time using repeated measures ANOVA. RESULTS: The injured limb showed a peak torque deficit of 9.6% compared to the uninjured limb at RTS (60°/s, p<0.001), but not 6-months following. The knee flexion angle of peak torque decreased over time for both limbs (60°/s, p<0.001). MRI revealed that 20.4% of the muscle cross-sectional area showed signs of edema at RTS with full resolution by the 6-month follow-up. Tendon volume of the injured limb tended to increase over time (p=0.108), while muscle volume decreased 4–5% in both limbs (p<0.001). CONCLUSION: Residual edema and deficits in isokinetic knee flexion strength were present at RTS, but resolved during the subsequent six months. This occurred despite MRI evidence of scar tissue formation (increased tendon volume) and muscle atrophy, suggesting that neuromuscular factors may contribute to the return of strength. PMID:23059864
Umehara, Jun; Ikezoe, Tome; Nishishita, Satoru; Nakamura, Masatoshi; Umegaki, Hiroki; Kobayashi, Takuya; Fujita, Kosuke; Ichihashi, Noriaki
2015-12-01
Decreased flexibility of the tensor fasciae latae is one factor that causes iliotibial band syndrome. Stretching has been used to improve flexibility or tightness of the muscle. However, no studies have investigated the effective stretching position for the tensor fasciae latae using an index to quantify muscle elongation in vivo. The aim of this study was to investigate the effects of hip rotation and knee angle on tensor fasciae latae elongation during stretching in vivo using ultrasonic shear wave elastography. Twenty healthy men participated in this study. The shear elastic modulus of the tensor fasciae latae was calculated using ultrasonic shear wave elastography. Stretching was performed at maximal hip adduction and maximal hip extension in 12 different positions with three hip rotation conditions (neutral, internal, and external rotations) and four knee angles (0°, 45°, 90°, and 135°). Two-way analysis of variance showed a significant main effect for knee angle, but not for hip rotation. The post-hoc test for knee angle indicated that the shear elastic modulus at 90° and 135° were significantly greater than those at 0° and 45°. Our results suggest that adding hip rotation to the stretching position with hip adduction and extension may have less effect on tensor fasciae latae elongation, and that stretching at >90° of knee flexion may effectively elongate the tensor fasciae latae. Copyright © 2015 Elsevier Ltd. All rights reserved.
Fleming, Braden C.; Brady, Mark F.; Bradley, Michael P.; Banerjee, Rahul; Hulstyn, Michael J.; Fadale, Paul D.
2008-01-01
Purpose To document the tibiofemoral (TF) compression forces produced during clinical initial graft tension protocols. Methods An image analysis system was used to track the position of the tibia relative to the femur in 11 cadaver knees. TF compression forces were quantified using thin-film pressure sensors. Prior to performing ACL reconstructions with patellar tendon grafts, measurements of TF compression force were obtained from the ACL-intact knee with knee flexion. ACL reconstructions were then performed using “force-based” and “laxity-based” graft tension approaches. Within each approach, high- and low-tension conditions were compared to the ACL-intact condition over the range of knee flexion angles. Results The TF compression forces for all initial graft tension conditions were significantly greater than that of the normal knee when the knee was in full extension (0°). The TF compression forces when using the laxity-based approach were greater than those produced with the force-based approach. However the laxity-based approach was necessary to restore normal laxity at the time of surgery. Conclusions The initial graft tension conditions produce different TF compressive force profiles at the time of surgery. A compromise must be made between restoring knee laxity or TF compressive forces when reconstructing the ACL with patellar tendon graft. Clinical Relevance The TF compression forces were greater in the ACL-reconstructed knee for all the initial graft tension conditions when compared to the ACL-intact knee, and that clinically relevant initial graft tension conditions produce different TF compressive forces. PMID:18760214
Relative variances of the cadence frequency of cycling under two differential saddle heights
Chang, Wen-Dien; Fan Chiang, Chin-Yun; Lai, Ping-Tung; Lee, Chia-Lun; Fang, Sz-Ming
2016-01-01
[Purpose] Bicycle saddle height is a critical factor for cycling performance and injury prevention. The present study compared the variance in cadence frequency after exercise fatigue between saddle heights with 25° and 35° knee flexion. [Methods] Two saddle heights, which were determined by setting the pedal at the bottom dead point with 35° and 25° knee flexion, were used for testing. The relative variances of the cadence frequency were calculated at the end of a 5-minute warm-up period and 5 minutes after inducing exercise fatigue. Comparison of the absolute values of the cadence frequency under the two saddle heights revealed a difference in pedaling efficiency. [Results] Five minutes after inducing exercise fatigue, the relative variances of the cadence frequency for the saddle height with 35° knee flexion was higher than that for the saddle height with 25° knee flexion. [Conclusion] The current finding demonstrated that a saddle height with 25° knee flexion is more appropriate for cyclists than a saddle height with 35° knee flexion. PMID:27065522
Impact of 10-weeks of yoga practice on flexibility and balance of college athletes
Polsgrove, M Jay; Eggleston, Brandon M; Lockyer, Roch J
2016-01-01
Background: With clearer evidence of its benefits, coaches, and athletes may better see that yoga has a role in optimizing performance. Aims: To determine the impact of yoga on male college athletes (N = 26). Methods: Over a 10-week period, a yoga group (YG) of athletes (n = 14) took part in biweekly yoga sessions; while a nonyoga group (NYG) of athletes (n = 12) took part in no additional yoga activity. Performance measures were obtained immediately before and after this period. Measurements of flexibility and balance, included: Sit-reach (SR), shoulder flexibility (SF), and stork stand (SS); dynamic measurements consisted of joint angles (JA) measured during the performance of three distinct yoga positions (downward dog [DD]; right foot lunge [RFL]; chair [C]). Results: Significant gains were observed in the YG for flexibility (SR, P = 0.01; SF, P = 0.03), and balance (SS, P = 0.05). No significant differences were observed in the NYG for flexibility and balance. Significantly, greater JA were observed in the YG for: RFL (dorsiflexion, l-ankle; P = 0.04), DD (extension, r-knee, P = 0.04; r-hip; P = 0.01; flexion, r-shoulder; P = 0.01) and C (flexion, r-knee; P = 0.01). Significant JA differences were observed in the NYG for: DD (flexion, r-knee, P = 0.01: r-hip, P = 0.05; r-shoulder, P = 0.03) and C (flexion r-knee, P = 0.01; extension, r-shoulder; P = 0.05). A between group comparison revealed the significant differences for: RFL (l-ankle; P = 0.01), DD (r-knee, P = 0.01; r-hip; P = 0.01), and C (r-shoulder, P = 0.02). Conclusions: Results suggest that a regular yoga practice may increase the flexibility and balance as well as whole body measures of male college athletes and therefore, may enhance athletic performances that require these characteristics. PMID:26865768
Quadricep and hamstring activation during drop jumps with changes in drop height.
Peng, Hsien-Te; Kernozek, Thomas W; Song, Chen-Yi
2011-08-01
Compare the muscle activation patterns of the quadricep-hamstring during drop jumps with increasing demands of drop heights. Observational. University biomechanics laboratory. Fifteen male and eight female college physical education students. Electromyographic activity of the rectus femoris (RF) and biceps femoris (BF) during the landing and takeoff phase of drop jumps from 20 to 60-cm heights. The ground contact time, vertical ground reaction force (vGRF), knee flexion angle during ground contact, and jump height after takeoff were also analyzed. The activation of RF was higher in the drop jump from 60-cm than that from 20- and 30-cm (comparing 107.0 ± 45.9 to 82.3 ± 30.8 and 88.9 ± 38.9 %MVIC, P<.05) during the landing phase. Activation of BF remained similar across all drop heights. Drop jump from 60-cm resulted in greater contact time during takeoff phase and peak vGRF, and resulted in greater maximum knee flexion but straighter knee at ground contact than from lower drop heights. At drop height of 60-cm, the altered knee muscular activation and movement patterns may diminish the effectiveness of plyometric training and increase the potential injury risk of knee. Copyright © 2010 Elsevier Ltd. All rights reserved.
Smale, Kenneth B; Potvin, Brigitte M; Shourijeh, Mohammad S; Benoit, Daniel L
2017-09-06
The recent development of a soft tissue artifact (STA) suppression method allows us to re-evaluate the tibiofemoral kinematics currently linked to non-contact knee injuries. The purpose of this study was therefore to evaluate knee joint kinematics and kinetics in six degrees of freedom (DoF) during the loading phases of a jump lunge and side cut using this in silico method. Thirty-five healthy adults completed these movements and their surface marker trajectories were then scaled and processed with OpenSim's inverse kinematics (IK) and inverse dynamics tools. Knee flexion angle-dependent kinematic constraints defined based on previous bone pin (BP) marker trajectories were then applied to the OpenSim model during IK and these constrained results were then processed with the standard inverse dynamics tool. Significant differences for all hip, knee, and ankle DoF were observed after STA suppression for both the jump lunge and side cut. Using clinically relevant effect size estimates, we conclude that STA contamination had led to misclassifications in hip transverse plane angles, knee frontal and transverse plane angles, medial/lateral and distractive/compressive knee translations, and knee frontal plane moments between the NoBP and the BP IK solutions. Our results have substantial clinical implications since past research has used joint kinematics and kinetics contaminated by STA to identify risk factors for musculoskeletal injuries. Copyright © 2017 Elsevier Ltd. All rights reserved.
Narayanan, Rajkishen; Lenz, Nathaniel; Werner, Jordan Alexander; Cross, Michael B; Hughes, Dean; Laster, Scott; Schwarzkopf, Ran
2018-04-13
Proper ligament tension in knee flexion within cruciate-retaining (CR) total knee arthroplasty has long been associated with clinical success; however, traditional balancing principles have assumed that the distal femoral joint line (DFJL) affects only extension. The purpose of this study was to determine the effect DFJL may have on ligament strains and tibiofemoral kinematics of CR knee designs in flexion. A computational analysis was performed using a musculoskeletal modeling system for two different knee implants, the high-flex CR (HFCR) and guided-motion CR (GMCR). Tibiofemoral kinematics and ligament strain were measured at 90-degree knee flexion while the implants' DFJL was incrementally shifted proximally. Femoral implant position and kinematics were used to determine the femur's anteroposterior position relative to the tibia. The change in the femoral medial condyle position relative to the tibia was 0.33 mm and 0.53 mm more anterior per each 1-mm elevation of the DFJL for HFCR and GMCR, respectively. The change in the lateral condyle position was 0.20 mm more anterior and 0.06 mm more posterior for HFCR and GMCR, respectively. The strain in the lateral and medial collateral ligaments changed minimally with elevation of the DFJL. In both implants, strain increased in the anterior lateral and posterior medial bundles of the posterior collateral ligament with elevation of the DFJL, whereas strain decreased in the iliotibial band and iliotibial patellar band. Our findings suggest that DFJL affects ligament tension at 90-degree knee flexion and therefore flexion balance for CR implants. Elevating the DFJL to address tight extension space in a CR knee while flexion space is well balanced could result in increased flexion tension especially when the flexion-extension mismatch is large. To achieve balanced flexion and extension, the amount of DFJL elevation may need to be reduced. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Domnick, Christoph; Frosch, Karl-Heinz; Raschke, Michael J; Vogel, Nils; Schulze, Martin; von Glahn, Mathias; Drenck, Tobias C; Herbort, Mirco
2017-10-01
To determine the static stabilizing effects of different anatomical structures of the posterolateral corner (PLC) of the knee in the lateral collateral ligament (LCL)-intact state. Thirteen fresh-frozen human cadaveric knees were dissected and tested using an industrial robot with an optical tracking system. Kinematics were determined for 134 N anterior/posterior loads, 10 N m valgus/varus loads, and 5 N m internal/external rotatory loads in 0°, 20°, 30°, 60°, and 90° of knee flexion. The PLC structures were dissected and consecutively released: (I) intact knee joint, (II) with released posterior cruciate ligament (PCL), (III) popliteomeniscal fibers, (IV) popliteofibular ligament, (V) arcuat and popliteotibial fibers, (VI) popliteus tendon (PLT), and (VII) LCL. Repeated-measures analysis of variance was performed with significance set at P < .05. After releasing the PCL, posterior tibial translation increased by 5.2 mm at 20° to 9.4 mm at 90° of joint flexion (P < .0001). A mild 1.8° varus instability was measured in 0° of flexion (P = .0017). After releasing the PLC structures, posterior tibial translation further increased by 2.9 mm at 20° to 5.9 mm at 90° of flexion (P < .05) and external rotation angle increased by 2.6° at 0° to 7.9° at 90° of flexion (P < .05, vs II). Varus stability did not decrease. Mild differences between states V and VI were found in 60° and 90° external rotation tests (2.1° and 3.1°; P < .05). The connecting ligaments/fibers to the PLT act as a primary static stabilizer against external rotatory loads and a secondary stabilizer against posterior tibial loads (when PCL is injured). After releasing these structures, most static stabilizing function of the intact PLT is lost. The PLC has no varus-stabilizing function in the LCL-intact knee. Anatomy and function of these structures for primary and secondary joint stability should be considered for clinical diagnostics and when performing surgery in the PLC. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Loading Patterns of the Posterior Cruciate Ligament in the Healthy Knee: A Systematic Review
List, Renate; Oberhofer, Katja; Fucentese, Sandro F.; Snedeker, Jess G.; Taylor, William R.
2016-01-01
Background The posterior cruciate ligament (PCL) is the strongest ligament of the knee, serving as one of the major passive stabilizers of the tibio-femoral joint. However, despite a number of experimental and modelling approaches to understand the kinematics and kinetics of the ligament, the normal loading conditions of the PCL and its functional bundles are still controversially discussed. Objectives This study aimed to generate science-based evidence for understanding the functional loading of the PCL, including the anterolateral and posteromedial bundles, in the healthy knee joint through systematic review and statistical analysis of the literature. Data sources MEDLINE, EMBASE and CENTRAL Eligibility criteria for selecting studies Databases were searched for articles containing any numerical strain or force data on the healthy PCL and its functional bundles. Studied activities were as follows: passive flexion, flexion under 100N and 134N posterior tibial load, walking, stair ascent and descent, body-weight squatting and forward lunge. Method Statistical analysis was performed on the reported load data, which was weighted according to the number of knees tested to extract average strain and force trends of the PCL and identify deviations from the norms. Results From the 3577 articles retrieved by the initial electronic search, only 66 met all inclusion criteria. The results obtained by aggregating data reported in the eligible studies indicate that the loading patterns of the PCL vary with activity type, knee flexion angle, but importantly also the technique used for assessment. Moreover, different fibres of the PCL exhibit different strain patterns during knee flexion, with higher strain magnitudes reported in the anterolateral bundle. While during passive flexion the posteromedial bundle is either lax or very slightly elongated, it experiences higher strain levels during forward lunge and has a synergetic relationship with the anterolateral bundle. The strain patterns obtained for virtual fibres that connect the origin and insertion of the bundles in a straight line show similar trends to those of the real bundles but with different magnitudes. Conclusion This review represents what is now the best available understanding of the biomechanics of the PCL, and may help to improve programs for injury prevention, diagnosis methods as well as reconstruction and rehabilitation techniques. PMID:27880849
Myer, Gregory D; Ford, Kevin R; Khoury, Jane; Succop, Paul; Hewett, Timothy E
2014-01-01
Objective Knee abduction moment (KAM) during landing predicts non-contact anterior cruciate ligament (ACL) injury risk with high sensitivity and specificity in female athletes. The purpose of this study was to employ sensitive laboratory (lab-based) tools to determine predictive mechanisms that underlie increased KAM during landing. Methods Female basketball and soccer players (N=744) from a single county public school district were recruited to participate in testing of anthropometrics, maturation, laxity/flexibility, strength and landing biomechanics. Linear regression was used to model KAM, and logistic regression was used to examine high (>25.25 Nm of KAM) versus low KAM as surrogate for ACL injury risk. Results The most parsimonious model included independent predictors (β±1 SE) (1) peak knee abduction angle (1.78±0.05; p<0.001), (2) peak knee extensor moment (0.17±0.01; p<0.001), (3) knee flexion range of motion (0.15±0.03; p<0.01), (4) body mass index (BMI) Z-score (−1.67±0.36; p<0.001) and (5) tibia length (−0.50±0.14; p<0.001) and accounted for 78% of the variance in KAM during landing. The logistic regression model that employed these same variables predicted high KAM status with 85% sensitivity and 93% specificity and a C-statistic of 0.96. Conclusions Increased knee abduction angle, quadriceps recruitment, tibia length and BMI with decreased knee flexion account for 80% of the measured variance in KAM during a drop vertical jump. Clinical relevance Females who demonstrate increased KAM are more responsive and more likely to benefit from neuromuscular training. These findings should significantly enhance the identification of those at increased risk and facilitate neuromuscular training targeted to this important risk factor (high KAM) for ACL injury. PMID:20558526
Influence of variable resistance loading on subsequent free weight maximal back squat performance.
Mina, Minas A; Blazevich, Anthony J; Giakas, Giannis; Kay, Anthony D
2014-10-01
The purpose of the study was to determine the potentiating effects of variable resistance (VR) exercise during a warm-up on subsequent free-weight resistance (FWR) maximal squat performance. In the first session, 16 recreationally active men (age = 26.0 ± 7.8 years; height = 1.7 ± 0.2 m; mass = 82.6 ± 12.7 kg) were familiarized with the experimental protocols and tested for 1 repetition maximum (1RM) squat lift. The subjects then visited the laboratory on 2 further occasions under either control or experimental conditions. During these conditions, 2 sets of 3 repetitions of either FWR (control) or VR (experimental) squat lifts at 85% of 1RM were performed; during the experimental condition, 35% of the load was generated from band tension. After a 5-minute rest, 1RM, 3D knee joint kinematics, and vastus medialis, vastus lateralis, rectus femoris, and semitendinosus electromyogram (EMG) signals were recorded simultaneously. No subject increased 1RM after FWR, however, 13 of 16 (81%) subjects increased 1RM after VR (mean = 7.7%; p < 0.01). Lower peak and mean eccentric (16-19%; p ≤ 0.05) and concentric (12-21%; p ≤ 0.05) knee angular velocities were observed during the 1RM following VR when compared with FWR, however, no differences in knee flexion angle (1.8°; p > 0.05) or EMG amplitudes (mean = 5.9%; p > 0.05) occurred. Preconditioning using VR significantly increased 1RM without detectable changes in knee extensor muscle activity or knee flexion angle, although eccentric and concentric velocities were reduced. Thus, VR seems to potentiate the neuromuscular system to enhance subsequent maximal lifting performance. Athletes could thus use VR during warm-up routines to maximize squat performance.
NASA Astrophysics Data System (ADS)
Wannaphan, Patsiri; Chanthasopeephan, Teeranoot
2016-11-01
Knee rehabilitation after total knee replacement arthroplasty is essential for patients during their post-surgery recovery period. This study is about designing one degree of freedom knee rehabilitation equipment to assist patients for their post-surgery exercise. The equipment is designed to be used in sitting position with flexion/extension of knee in sagittal plane. The range of knee joint motion is starting from 0 to 90 degrees angle for knee rehabilitation motion. The feature includes adjustable link for different human proportions and the torque feedback control at knee joint during rehabilitation and the control of flexion/extension speed. The motion of the rehabilitation equipment was set to move at low speed (18 degrees/sec) for knee rehabilitation. The rehabilitation link without additional load took one second to move from vertical hanging up to 90° while the corresponding torque increased from 0 Nm to 2 Nm at 90°. When extra load is added, the link took 1.5 seconds to move to 90° The torque is then increased from 0 Nm to 4 Nm. After a period of time, the speed of the motion can be varied. User can adjust the motion to 40 degrees/sec during recovery activity of the knee and users can increase the level of exercise or motion up to 60 degrees/sec to strengthen the muscles during throughout their rehabilitation program depends on each patient. Torque control is included to prevent injury. Patients can use the equipment for home exercise to help reduce the number of hospital visit while the patients can receive an appropriate therapy for their knee recovery program.
Varadarajan, Kartik M; Harry, Rubash E; Johnson, Todd; Li, Guoan
2009-10-01
In vitro systems provide a powerful means to evaluate the efficacy of total knee arthroplasty (TKA) in restoring normal knee kinematics. The Oxford knee rig (OKR) and the robotic knee testing system (RKTS) represent two systems that have been extensively used to study TKA biomechanics. Nonetheless, a frequently asked question is whether in vitro simulations can capture the in vivo behavior of the knee. Here, we compared the flexion-extension kinematics of intact knees and knees after TKA tested on the OKR and RKTS, to results of representative in vivo studies. The goal was to determine if the in vitro systems could capture the key kinematic features of knees in healthy subjects and TKA patients. Results showed that the RKTS and the OKR can replicate the femoral rollback and 'screw home' tibial rotation between 0 degrees and 30 degrees flexion seen in healthy subjects, and the reduced femoral rollback and absence of 'screw home' motion in TKA patients. The RKTS also replicated the overall internally rotated position of the tibia beyond 30 degrees flexion. However, ability of the OKR to replicate the internally rotated position of the knee beyond 30 degrees flexion was inconsistent. These data could aid in validation of new in vitro systems and physiologic interpretations of in vitro results.
Sun, Hao; Zhou, Lin; Li, Fengsheng; Duan, Jun
2017-02-01
Young active patients with medial knee osteoarthritis (OA) combined with varus leg alignment can be treated with high tibial osteotomy (HTO) to stop the progression of OA and avoid or postpone total knee arthroplasty (TKA). Closing-wedge osteotomy (CWO) and opening-wedge osteotomy (OWO) are the most commonly used osteotomy techniques. The purpose of this study was to compare the clinical and radiologic outcomes and complications between OWO and CWO. We retrospectively evaluated 23 studies including 17 clinical trials from published databases from their inception to May 2015. We evaluated the clinical outcomes including operation time, visual analog scale (VAS), maximal flexion, and hospital for special surgery knee (HSS) score. The radiologic outcomes included patellar height measured by posterior tibial slope angle, hip-knee-ankle (HKA) angle, femorotibial (FT) axis, and limb length. Complications recorded included the incidence of deep vein thrombosis (DVT), common peroneal nerve injury, opposite cortical fracture, etc. There were no differences in most of the clinical outcomes except the operation time. OWO increased the posterior slope angle and limb length, decreased the patellar height, and provided higher accuracy of correction. CWO led to a higher incidence of opposite cortical fracture. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Functional assessment of a surgical robot for reduction of lower limb fractures.
Hung, Shuo-Suei; Lee, Ming-Yih
2010-12-01
This paper presents a novel robot designed for reduction of lower limb fractures, with the additional features of automatic controlled flexion of the knee joint, individual traction of thigh and leg, and foot rotation. The aim of this design is to assist the orthopaedic surgeon to perform better fracture reduction through motor control, in contrast to current manual control, and the results of assessments of its functions on normal subjects are presented in this paper. The robot was designed to be mounted onto the operation table, and was controlled through open switch relay. Functional assessments were conducted on six healthy volunteers in terms of knee joint motion and lower limb traction; measurement of angle and distance was calculated from data obtained by a 3D ultrasonic motion system (Zebris(®) ). The results showed a good correlation of the flexion angle between the robot and the subjects at the knee joint. In the traction tests, a steady lengthening of the proximal as well as the distal segment of the robot was observed, and a slight increase in subjects' limb length was also recorded, which might be due to distraction in the joint space. This automatic control fracture table has distinct features compared with the conventional ones, and it is believed to be of assistance to surgeons when performing fracture fixations. Copyright © 2010 John Wiley & Sons, Ltd.
Effect of posterior cruciate ligament rupture on the radial displacement of lateral meniscus.
Lei, Pengfei; Sun, Rongxin; Hu, Yihe; Li, Kanghua; Liao, Zhan
2015-06-01
The relationship between lateral meniscus tear and posterior cruciate ligament injury is not well understood. The present study aims to investigate and assess the effect of posterior cruciate ligament rupture on lateral meniscus radial displacement at different flexion angles under static loading conditions. Twelve fresh human cadaveric knee specimens were divided into four groups such as posterior cruciate ligament intact, anterolateral band rupture, posteromedial band rupture and posterior cruciate ligament complete rupture groups, according to the purpose and order of testing. Radial displacement of lateral meniscus was measured under different loads (200-1000N) at 0°, 30°, 60°, and 90° of knee flexion. Compared with posterior cruciate ligament intact group, the displacement values of lateral meniscus in anterolateral band rupture group increased at 0° flexion with 600N, 800N, and 1000N and at 30°, 60° and 90° flexion under all loading conditions. Posteromedial band rupture group exhibited higher displacement at 0° flexion under all loading conditions, at 30° and 60° flexion with 600, 800N and 1000N, and at 90° flexion with 400N, 600N, 800N, and 1000N than the posterior cruciate ligament intact group. The posterior cruciate ligament complete rupture group had a higher displacement value of lateral medial meniscus at 0°, 30°, 60° and 90° flexion under all loading conditions, as compared to the posterior cruciate ligament intact group. The study concludes that partial and complete rupture of the posterior cruciate ligament can trigger the increase of radial displacement on lateral meniscus. Copyright © 2015 Elsevier Ltd. All rights reserved.
Shono, Tomoki; Masumoto, Kenji; Fujishima, Kazutaka; Hotta, Noboru; Ogaki, Tetsuro; Adachi, Takahiro
2007-11-01
This study sought to determine the characteristics of gait patterns and muscle activity in the lower extremities of elderly women during underwater treadmill walking against water flow. Eight female subjects (61.4+/-3.9 y) performed underwater and land treadmill walking at varying exercise intensities and velocities. During underwater walking (water level at the xiphoid process) using the Flowmill, which has a treadmill at the base of a water flume, the simultaneous belt and water flow velocities were set to 20, 30 and 4 m.min(-1). Land walking velocities were set to 40, 60 and 80 m.min(-1). Oxygen uptake and heart rate were measured during both walking exercises. Maximum and minimum knee joint angles, and mean angular velocities of knee extension and knee flexion in the swing phase were calculated using two-dimensional motion analysis. Electromyograms were recorded using bipolar surface electrodes for five muscles: the tibialis anterior (TA), medial gastrocnemius (MG), vastus medialis (VM), rectus femoris (RF) and biceps femoris (BF). At the same exercise intensity level, cadence was almost half that on land. Step length did not differ significantly because velocity was halved. Compared to land walking, the maximum and minimum knee joint angles were significantly smaller and the mean angular velocity of knee extension was significantly lower. Knee extension in the swing phase was limited by water resistance. While the muscle activity levels of TA, VM and BF were almost the same as during land walking, those of MG and RF were lower. At the same velocity, exercise intensity was significantly higher than during land walking, cadence was significantly lower, and step length significantly larger. The knee joint showed significantly smaller maximum and minimum angles, and the mean angular velocity of knee flexion was significantly larger. The muscle activity levels of TA, VM, and BF increased significantly in comparison with land walking, although those of MG and RF did not significantly differ. Given our findings, it appears that buoyancy, lower cadence, and a moving floor influenced the muscle activity level of MG and RF at the same exercise intensity level and at the same velocity. These results show promise of becoming the basic data of choice for underwater walking exercise prescription.
[Mini-subvastus approach for total knee replacement].
Halder, Andreas; Beier, Alexander; Neumann, Wolfram
2009-03-01
Total knee replacement in minimally invasive technique without any trauma to the extensor apparatus and with soft-tissue-referenced bone resections. Only the subvastus approach preserves the integrity of the extensor apparatus and has therefore been modified to become a minimally invasive technique with a shorter skin incision and lateralization instead of eversion of the patella. Soft-tissue balancing is done through this direct anterior approach. Mild to moderate varus osteoarthritis of the knee up to 15 degrees of malalignment, mild and passively correctable valgus osteoarthritis of the knee up to 10 degrees of malalignment. Severe, contract varus osteoarthritis of the knee, severe and moderate, contract valgus osteoarthritis of the knee, severe obesity, exceptionally muscular patients, decreased skin perfusion. Central skin incision from the superior pole of the patella to the tibial tubercle. Exposure of the medial retinaculum and mobilization of the vastus medialis muscle subcutaneously. Incision of the medial retinaculum and blunt separation of the vastus medialis muscle from the intermuscular septum. Lateralization of the patella and flexion of the knee joint. Resection of the tibia perpendicular to the diaphysis. Adjustment of the anteroposterior (AP) resection block at the level of the anterior femoral cortex and of rotation by applying equal tension to the collateral ligaments. Balancing of soft-tissue tension in flexion gap by release, if necessary. After AP resection fixation of distal resection block in planned valgus angle. Balancing of soft-tissue tension in extension gap by release, if necessary. After distal femur resection facet resection, adaptation of posterior femoral condyles, and implantation of prosthesis. Check on stability and range of motion. Wound closure. Full weight bearing from the 1st postoperative day, CPM (continuous passive motion) with up to 90 degrees flexion with peridural anesthesia as tolerated, stair climbing starting on the 7th postoperative day. 100 patients were randomized to total knee replacement via a parapatellar or subvastus approach. Radiologically, there were no differences in operative precision or leg alignment. Patients treated minimally invasively suffered less pain and achieved a higher flexion of 110 degrees versus 95 degrees 6 weeks postoperatively. However, there were two cases of delayed wound healing in this group. The surgical technique is demanding and the operating time is longer. Long-term results are still missing.
[Correlation analysis on the disorders of patella-femoral joint and torsional deformity of tibia].
Sun, Zhen-Jie; Yuan, Yi; Liu, Rui-Bo
2015-03-01
To reveal the possible mechanism involved in patella-femoral degenerative arthritis (PFDA) in- duced by torsion-deformity of tibia via analyzing the relationship between torsion-deformity of the tibia in patients with PFDA and the disorder of patella-femoral joint under the static and dynamic conditions. From October 2009 to October 2010, 50 patients (86 knees, 24 knees of male patients and 62 knees of female patients) with PFDA were classified as disease group and 16 people (23 knees, 7 knees of males and 16 knees of females) in the control group. The follow indexes were measured: the torsion-angle of tibia on CT scanning imagings, the patella-femoral congruence angle and lateral patella-femoral angle under static and dynamic conditions when the knee bent at 30 degrees of flexion. Based on the measurement results, the relationship between the torsion-deformity of tibias and the disorders of patella-femoral joints in patients with PFDA were analyzed. Finally,the patients were divided into three groups including large torsion-angle group, small torsion-angle group and normal group according to the size of torsion-angle, in order to analyze the relationship between torsion-deformity and disorders of patella-femoral joint, especially under the dynamic conditions. Compared with patients without PFDA, the ones with PFDA had bigger torsion-angle (30.30 ± 7.11)° of tibia, larger patella-femoral congruence angle (13.20 ± 3.94)° and smaller lateral patella-femoral angle (12.30 ± 3.04)°. The congruence angle and lateral patella-femoral angle under static and dynamic conditions had statistical differences respectively in both too-big torsion-angle group and too-small torsion-angle group. The congruence angle and lateral patella-femoral angle under static and dynamic conditions had no statistical differences in normal torsion-angle group. Torsion-deformity of tibia is the main reason for disorder of patella-femoral joint in the patients with PFDA. Torsion-deformity of tibia is always accompanied by instability of patella-femoral joint,especially under the dynamic condition, thus causing PFDA. It can not only provide arrangement information and degenerative condition of patella-femoral joint,but also provide guidance through the analysis on the relationship for better clinical prevention and early treatment of degenerative bone and joint disease.
Hajizadeh, Maryam; Hashemi Oskouei, Alireza; Ghalichi, Farzan; Sole, Gisela
2016-06-01
Biomechanical changes have been reported for patients with anterior cruciate ligament deficiency (ACLD) and anterior cruciate ligament (ACL reconstruction) (ACLR), likely due to loss of stability and changes in proprioception and neuromotor control. This review evaluated kinematics and kinetics of ACLD and ACLR knees, compared with those on the contralateral uninjured sides, as well as and those in asymptomatic controls during stair navigation. This is a systematic review and meta-analysis. Electronic database searches were conducted from their original available dates to January 2015. Studies that included participants with ACLD or ACLR and reported knee joint angles or moments during stair ascent or descent were included. Nine studies met the inclusion criteria, and the methodological quality of these was assessed with a modified Downs and Black checklist. Effect sizes for differences between injured leg and uninjured contralateral leg or controls were calculated, and meta-analyses were performed if two or more studies considered the same variable. Quality assessment showed an average (± standard deviation) of 70.3% ± 7.2%. Meta-analysis showed less knee flexion at initial contact for ACLR knees compared with that in contralateral knees during stair ascent, with a moderate effect size and minimal heterogeneity. Knees with ACLD showed less peak knee flexion compared with that on contralateral sides during stair ascent, with minimal heterogeneity. External knee flexion moments were lower for ACLR compared with those in controls and contralateral sides during ascent and descent, whereas these moments were decreased for the ACLD compared with controls only during ascent. Meta-analysis results exhibited moderate/high heterogeneity or small/trivial effect sizes. Differences for kinematics and kinetics for the ACL-injured knees indicate long-term compensatory and asymmetric movement patterns while ascending and descending stairs. Due to the heterogeneity as well as the small numbers of available studies, the consequences of these differences in terms of long-term function or posttraumatic osteoarthritis need further exploration. Copyright © 2016. Published by Elsevier Inc.
Lower Extremity Kinematics During a Drop Jump in Individuals With Patellar Tendinopathy
Rosen, Adam B.; Ko, Jupil; Simpson, Kathy J.; Kim, Seock-Ho; Brown, Cathleen N.
2015-01-01
Background: Patellar tendinopathy (PT) is a common degenerative condition in physically active populations. Knowledge regarding the biomechanics of landing in populations with symptomatic PT is limited, but altered mechanics may play a role in the development or perpetuation of PT. Purpose: To identify whether study participants with PT exhibited different landing kinematics compared with healthy controls. Study Design: Controlled laboratory study. Methods: Sixty recreationally active participants took part in this study; 30 had current signs and symptoms of PT, including self-reported pain within the patellar tendon during loading activities for at least 3 months and ≤80 on the Victorian Institute of Sport Assessment Scale–Patella (VISA-P). Thirty healthy participants with no history of PT or other knee joint pathology were matched by sex, age, height, and weight. Participants completed 5 trials of a 40-cm, 2-legged drop jump followed immediately by a 50% maximum vertical jump. Dependent variables of interest included hip, knee, and ankle joint angles at initial ground contact, peak angles, and maximum angular displacements during the landing phase in 3 planes. Independent-samples t tests (P ≤ .05) were utilized to compare the joint angles and angular displacements between PT and control participants. Results: Individuals with PT displayed significantly decreased peak hip (PT, 59.2° ± 14.6°; control, 67.2° ± 13.9°; P = .03) and knee flexion angles (PT, 74.8° ± 13.2°; control, 82.5° ± 9.0°; P = .01) compared with control subjects. The PT group displayed decreased maximum angular displacement in the sagittal plane at the hip (PT, 49.3° ± 10.8°; control, 55.2° ± 11.4°; P = .04) and knee (PT, 71.6° ± 8.4°; control, 79.7° ± 8.3°; P < .001) compared with the control group. Conclusion: Participants with PT displayed decreased maximum flexion and angular displacement in the sagittal plane, at both the knee and the hip. The altered movement patterns in those with PT may be perpetuating symptoms associated with PT and could be due to the contributions of the rectus femoris during dynamic movement. Clinical Relevance: Based on kinematic alterations in symptomatic participants, rehabilitation efforts may benefit from focusing on both the knee and the hip to treat symptoms associated with PT. PMID:26665034
Khandha, Ashutosh; Manal, Kurt; Wellsandt, Elizabeth; Capin, Jacob; Snyder-Mackler, Lynn; Buchanan, Thomas S.
2016-01-01
The objective of the study was to evaluate differences in gait mechanics 5 years after unilateral anterior cruciate ligament reconstruction surgery, for non-osteoarthritic (n = 24) versus osteoarthritic (n = 9) subjects. For the involved knee, the osteoarthritic group demonstrated significantly lower peak knee flexion angles (non-osteoarthritic = 24.3 ± 4.6°, osteoarthritic = 19.1 ± 2.9°, p = 0.01) and peak knee flexion moments (non-osteoarthritic = 5.3 ± 1.2% Body Weight × Height, osteoarthritic = 4.4 ± 1.2% Body Weight × Height, p = 0.05). Differences in peak knee adduction moment approached significance, with a higher magnitude for the osteoarthritic group (non-osteoarthritic = 2.4 ±0.8% Body Weight × Height, osteoarthritic = 2.9 ± 0.5% Body Weight × Height, p = 0.09). Peak medial compartment joint load was evaluated using electromyography-informed neuromusculoskeletal modeling. Peak medial compartment joint load in the involved knee for the two groups was not different (non-osteoarthritic = 2.4 ± 0.4 Body Weight, osteoarthritic = 2.3 ± 0.6 Body Weight). The results suggest that subjects with dissimilar peak knee moments can have similar peak medial compartment joint load magnitudes. There was no evidence of inter-limb asymmetry for either group. Given the presence of inter-group differences (non-osteoarthritic vs. osteoarthritic) for the involved knee, but an absence of inter-limb asymmetry in either group, it may be necessary to evaluate how symmetry is achieved, over time, and to differentiate between good versus bad inter-limb symmetry, when evaluating knee gait parameters. PMID:27082166
Brady, Mark F.; Bradley, Michael P.; Fleming, Braden C.; Fadale, Paul D.; Hulstyn, Michael J.; Banerjee, Rahul
2007-01-01
Background The initial tension applied to an ACL graft at the time of fixation modulates knee motion and the tibiofemoral compressive loads. Purpose To establish the relationships between initial graft tension, tibiofemoral compressive force, and the neutral tibiofemoral position in the cadaver knee. Study Design Controlled Laboratory Study. Methods The tibiofemoral compressive forces and joint positions were determined in the ACL-intact knee at 0°, 20° and 90° knee flexion. The ACL was excised and reconstructed with a patellar tendon graft using graft tensions of 1, 15, 30, 60 and 90 N applied at 0°, 20° and 90° knee flexion. The compressive forces and neutral positions were compared between initial tension conditions and the ACL-intact knee. Results Increasing initial graft tension increased the tibiofemoral compressive forces. The forces in the medial compartment were 1.8 times those in the lateral compartment. The compressive forces were dependent on the knee angle at which the tension was applied. The greatest compressive forces occurred when the graft was tensioned with the knee in extension. An increase in initial graft tension caused the tibia to rotate externally compared to the ACL-intact knee. Increases in initial graft tension also caused a significant posterior translation of the tibia relative to the femur. Conclusions Different initial graft tension protocols produced predictable changes in the tibiofemoral compressive forces and joint positions. Clinical Relevance The tibiofemoral compressive force and neutral joint position were best replicated with a low graft tension (1–15 N) when using a patellar tendon graft. PMID:17218659
Non-invasive quantification of lower limb mechanical alignment in flexion
Deakin, Angela; Fogg, Quentin A.; Picard, Frederic
2014-01-01
Objective Non-invasive navigation techniques have recently been developed to determine mechanical femorotibial alignment (MFTA) in extension. The primary aim of this study was to evaluate the precision and accuracy of an image-free navigation system with new software designed to provide multiple kinematic measurements of the knee. The secondary aim was to test two types of strap material used to attach optical trackers to the lower limb. Methods Seventy-two registrations were carried out on 6 intact embalmed cadaveric specimens (mean age: 77.8 ± 12 years). A validated fabric strap, bone screws and novel rubber strap were used to secure the passive tracker baseplate for four full experiments with each knee. The MFTA angle was measured under the conditions of no applied stress, valgus stress, and varus stress. These measurements were carried out at full extension and at 30°, 40°, 50° and 60° of flexion. Intraclass correlation coefficients, repeatability coefficients, and limits of agreement (LOA) were used to convey precision and agreement in measuring MFTA with respect to each of the independent variables, i.e., degree of flexion, applied coronal stress, and method of tracker fixation. Based on the current literature, a repeatability coefficient and LOA of ≤3° were deemed acceptable. Results The mean fixed flexion for the 6 specimens was 12.8° (range: 6–20°). The mean repeatability coefficient measuring MFTA in extension with screws or fabric strapping of the baseplate was ≤2°, compared to 2.3° using rubber strapping. When flexing the knee, MFTA measurements taken using screws or fabric straps remained precise (repeatability coefficient ≤3°) throughout the tested range of flexion (12.8–60°); however, using rubber straps, the repeatability coefficient was >3° beyond 50° flexion. In general, applying a varus/valgus stress while measuring MFTA decreased precision beyond 40° flexion. Using fabric strapping, excellent repeatability (coefficient ≤2°) was observed until 40° flexion; however, beyond 50° flexion, the repeatability coefficient was >3°. As was the case with precision, agreement between the invasive and non-invasive systems was satisfactory in extension and worsened with flexion. Mean limits of agreement between the invasive and non-invasive system using fabric strapping to assess MFTA were 3° (range: 2.3–3.8°) with no stress applied and 3.9° (range: 2.8–5.2°) with varus and valgus stress. Using rubber strapping, the corresponding values were 4.4° (range: 2.8–8.5°) with no stress applied, 5.5° (range: 3.3–9.0°) with varus stress, and 5.6° (range: 3.3–11.9°) with valgus stress. Discussion Acceptable precision and accuracy may be possible when measuring knee kinematics in early flexion using a non-invasive system; however, we do not believe passive trackers should be mounted with rubber strapping such as was used in this study. Flexing the knee appears to decrease the precision and accuracy of the system. The functions of this new software using image-free navigation technology have many potential clinical applications, including assessment of bony and soft tissue deformity, pre-operative planning, and post-operative evaluation, as well as in further pure research comparing kinematics of the normal and pathological knee. PMID:24856249
Leppänen, Mari; Pasanen, Kati; Krosshaug, Tron; Kannus, Pekka; Vasankari, Tommi; Kujala, Urho M.; Bahr, Roald; Perttunen, Jarmo; Parkkari, Jari
2017-01-01
Background: Stiff landings with less knee flexion and high vertical ground-reaction forces have been shown to be associated with an increased risk of anterior cruciate ligament (ACL) injury. The literature on the association between other sagittal plane measures and the risk of ACL injuries with a prospective study design is lacking. Purpose: To investigate the relationship between selected sagittal plane hip, knee, and ankle biomechanics and the risk of ACL injury in young female team-sport athletes. Study Design: Case-control study; Level of evidence, 3. Methods: A total of 171 female basketball and floorball athletes (age range, 12-21 years) participated in a vertical drop jump test using 3-dimensional motion analysis. All new ACL injuries, as well as match and training exposure data, were recorded for 1 to 3 years. Biomechanical variables, including hip and ankle flexion at initial contact (IC), hip and ankle ranges of motion (ROMs), and peak external knee and hip flexion moments, were selected for analysis. Cox regression models were used to calculate hazard ratios (HRs) with 95% CIs. The combined sensitivity and specificity of significant test variables were assessed using a receiver operating characteristic (ROC) curve analysis. Results: A total of 15 noncontact ACL injuries were recorded during follow-up (0.2 injuries/1000 player-hours). Of the variables investigated, landing with less hip flexion ROM (HR for each 10° increase in hip ROM, 0.61 [95% CI, 0.38-0.99]; P < .05) and a greater knee flexion moment (HR for each 10-N·m increase in knee moment, 1.21 [95% CI, 1.04-1.40]; P = .01) was significantly associated with an increased risk of ACL injury. Hip flexion at IC, ankle flexion at IC, ankle flexion ROM, and peak external hip flexion moment were not significantly associated with the risk of ACL injury. ROC curve analysis for significant variables showed an area under the curve of 0.6, indicating a poor combined sensitivity and specificity of the test. Conclusion: Landing with less hip flexion ROM and a greater peak external knee flexion moment was associated with an increased risk of ACL injury in young female team-sport players. Studies with larger populations are needed to confirm these findings and to determine the role of ankle flexion ROM as a risk factor for ACL injury. Increasing knee and hip flexion ROMs to produce soft landings might reduce knee loading and risk of ACL injury in young female athletes. PMID:29318174
Variations in medial-lateral hamstring force and force ratio influence tibiofemoral kinematics.
Shalhoub, Sami; Fitzwater, Fallon G; Cyr, Adam J; Maletsky, Lorin P
2016-10-01
A change in hamstring strength and activation is typically seen after injuries or invasive surgeries such as anterior cruciate reconstruction or total knee replacement. While many studies have investigated the influence of isometric increases in hamstring load on knee joint kinematics, few have quantified the change in kinematics due to a variation in medial to lateral hamstring force ratio. This study examined the changes in knee joint kinematics on eight cadaveric knees during an open-chain deep knee bend for six different loading configurations: five loaded hamstring configurations that varied the ratio of a total load of 175 N between the semimembranosus and biceps femoris and one with no loads on the hamstring. The anterior-posterior translation of the medial and lateral femoral condyles' lowest points along proximal-distal axis of the tibia, the axial rotation of the tibia, and the quadriceps load were measured at each flexion angle. Unloading the hamstring shifted the medial and lateral lowest points posteriorly and increased tibial internal rotation. The influence of unloading hamstrings on quadriceps load was small in early flexion and increased with knee flexion. The loading configuration with the highest lateral hamstrings force resulted in the most posterior translation of the medial lowest point, most anterior translation of the lateral lowest point, and the highest tibial external rotation of the five loading configurations. As the medial hamstring force ratio increased, the medial lowest point shifted anteriorly, the lateral lowest point shifted posteriorly, and the tibia rotated more internally. The results of this study, demonstrate that variation in medial-lateral hamstrings force and force ratio influence tibiofemoral transverse kinematics and quadriceps loads required to extend the knee. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1707-1715, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Biomechanics of front and back squat exercises
NASA Astrophysics Data System (ADS)
Braidot, A. A.; Brusa, M. H.; Lestussi, F. E.; Parera, G. P.
2007-11-01
Squat constitutes one of the most popular exercises to strengthen the muscles of the lower limbs. It is considered one of the most widely spread exercises for muscle sport training and is part of the competition movements comprised within olympic weight-lifting. In physical rehabilitation, squats are used for muscular recovery after different injuries of the lower limbs, especially the knee. In previous anterior cruciate ligament injuries, the mini-squats are generally used, in a knee flexion motion range from 0° to 50° because in this range the shear forces, the tibiofemoral and patellofemoral compression forces decrease related to greater flexion angles. The aim of this work is to make a comparative bidimensional study of the kinematic and dynamic variables of the excecution of the parallel squat exercise with the front and back bar. It is observed in the knee a better development of energy with the front bar, allowing a better muscular exercise with the same load. The mean power absorbed by the hip with the back bar is considerably greater, associated to the speed of the gesture.
Fukaya, Takashi; Mutsuzaki, Hirotaka; Okubo, Tomoyuki; Mori, Koichi; Wadano, Yasuyoshi
2016-08-01
The knee joint movement during the stance phase is affected by altered ankle movement and the center of pressure (COP). However the relationships between changes in the center of pressure (COP) and the altered kinematics and kinetics of the ankle and knee joints in patients with osteoarthritis (OA) of the knee are not well understood. The purpose of this study was to determine the relationships between changes in the COP and the altered kinematic and kinetic variables in ankle and knee joints during the stance phase in patients with medial knee OA. Fourteen patients with knee OA (21 knees) and healthy subjects were assessed by gait analysis using an eight-camera motion analysis system to record forward and lateral shifts in the COP and the angle and net internal moments of the knee and ankle joint. Spearman rank-correlation coefficients were used to determine the relationship between these results. In knees with medial OA, lateral shifts in the COP were correlated with knee flexion angle. Lateral shifts in the COP were correlated with the second peak of the knee extensor moment and correlated with the knee abductor moment. In patients with medial knee OA, lateral shifts in the COP were negatively correlated with the kinematic and kinetic variables in the sagittal plane of the knee joints. Controlling such lateral shifts in the COP may thus be an effective intervention for mechanical loads on the knee during the stance phase in patients with knee OA. Copyright © 2016 Elsevier B.V. All rights reserved.
Walsh, Gregory S
2017-10-01
The importance of warm up procedures prior to athletic performance is well established. A common component of such procedures is muscle stretching. There is conflicting evidence regarding the effect of static stretching (SS) as part of warm up procedures on knee joint position sense (KJPS) and the effect of dynamic stretching (DS) on KJPS is currently unknown. The aim of this study was to determine the effect of dynamic and static stretching as part warm up procedures on KJPS and knee extension and flexion strength. This study had a randomised cross-over design and ten healthy adults (20±1years) attended 3 visits during which baseline KJPS, at target angles of 20° and 45°, and knee extension and flexion strength tests were followed by 15min of cycling and either a rest period (CON), SS, or DS and repeat KJPS and strength tests. All participants performed all conditions, one condition per visit. There were warm up×stretching type interactions for KJPS at 20° (p=0.024) and 45° (p=0.018), and knee flexion (p=0.002) and extension (p<0.001) strength. The SS and DS improved KJPS but CON condition did not and SS decreased strength. No change in strength was present for DS or CON. Both SS and DS improve KJPS as part of pre-exercise warm up procedures. However, the negative impact of SS on muscle strength limits the utility of SS before athletic performance. If stretching is to be performed as part of a warm up, DS should be favoured over SS. Copyright © 2017 Elsevier B.V. All rights reserved.
Liao, C-D; Huang, Y-C; Chiu, Y-S; Liou, T-H
2017-09-01
Obesity may influence postoperative rehabilitation outcomes after total knee replacement (TKR). The aim of this study was to evaluate the effects of body mass index (BMI) on the progression of inpatient rehabilitation using continuous passive motion (CPM) and its treatment outcomes. A retrospective study was conducted in a rehabilitation centre. In total, 354 patients undergoing primary TKR were enrolled through medical chart review. All patients commenced the CPM programme immediately after surgery and continued until hospital discharge. Knee flexion, pain score, and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) physical function score. Patients were divided into five BMI groups: normal weight (n=59), overweight (n=95), Class I obesity (n=90), Class II obesity (n=82) and Class III obesity (n=28). All outcome measures were recorded at admission; daily during the inpatient stay; at discharge; and at 1-, 3- and 6-month follow-up assessments. During CPM exercises, obese patients had a smaller initial flexion angle (P<0.001) and a smaller daily increment in the CPM motion arc (P<0.001) compared with patients of normal weight. Severe obesity was associated with poor knee flexion [adjusted odds ratio (aOR) 11.9, 95% confidence interval (CI) 3.49 to 40.94, P<0.001] and WOMAC physical function score (aOR 5.09, 95% CI 1.62 to 16.03, P=0.005) at 6-month follow-up. Obesity had a negative effect on progress during the CPM protocol, which commenced immediately after surgery and continued until discharge. Obesity was also associated with poorer self-reported function at 6-month follow-up. Copyright © 2016 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
Mizuno, Shiho; Sonoda, Shigeru; Takeda, Kotaro; Maeshima, Shinichiro
2016-04-01
Quantification of increased muscle tone for patients with spasticity has been performed to date using various devices to replace the manual scales, such as the modified Ashworth scale or the Tardieu scale. We developed a device that could measure resistive plantar flexion (PF) torque of the ankle during passive dorsiflexion (DF) as an indicator of muscle tone of ankle plantar flexors. The primary objective was to explore the test-retest intrarater reliability of a custom-built device. Participants were 11 healthy subjects (7 men, 4 women; mean age 47.0 years) and 22 patients with poststroke hemiplegia (11 hemorrhagic, 11 ischemic; 14 men, 8 women; mean age 57.2 years). The device was affixed to the ankle. Subjects were seated with knees either flexed or extended. The ankle was passively dorsiflexed from 20° of PF to more than 10° of DF at 5°/second (slow stretch) or 90°/second (fast stretch). Angle and torque were measured twice during the stretches. The intraclass correlation coefficients (ICCs) of torque at 10° of DF (T10) in the 4 conditions-slow and fast stretches with knee flexed or extended-were calculated. The T10 ICCs of the 4 conditions were .95-.99 in both groups. The healthy subjects showed significantly higher T10 of knee extension than of knee flexion during slow and fast stretches. The patients showed increased velocity-dependent torque during fast stretches. Excellent reliability was observed. The device is suitable for measuring resistive PF torque during passive stretch in a flexed knee condition. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Hammond, Connor A; Hatfield, Gillian L; Gilbart, Michael K; Garland, S Jayne; Hunt, Michael A
2017-02-01
Femoroacetabular impingement is a pathomechanical hip condition leading to pain and impaired physical function. It has been shown that those with femoroacetabular impingement exhibit altered gait characteristics during level walking and stair climbing, and decreased muscle force production during isometric muscle contractions. However, no studies to-date have looked at trunk kinematics or muscle activation during dynamic movements such as stair climbing in this patient population. The purpose of this study was to compare biomechanical outcomes (trunk and lower limb kinematics as well as lower limb kinetics and muscle activation) during stair climbing in those with and without symptomatic femoroacetabular impingement. Trunk, hip, knee and ankle kinematics, as well as hip, knee and ankle kinetics and muscle activity of nine lower limb muscles were collected during stair climbing for 20 people with clinical and radiographic femoroacetabular impingement and compared to 20 age- and sex-matched pain-free individuals. Those with femoroacetabular impingement ascended the stairs slower (effect size=0.82), had significantly increased peak trunk forward flexion angles (effect size=0.99) and external hip flexion moments (effect size=0.94) and had decreased peak external knee flexion moments (effect size=0.90) compared to the control group. Findings from this study indicate that while those with and without femoroacetabular impingement exhibit many biomechanical similarities when ascending stairs, differences in trunk forward flexion and joint kinetics indicate some important differences. Further longitudinal research is required to elucidate the cause of these differences as well as the clinical relevance. Copyright © 2017 Elsevier Ltd. All rights reserved.
Control of speed during the double poling technique performed by elite cross-country skiers.
Lindinger, Stefan Josef; Stöggl, Thomas; Müller, Erich; Holmberg, Hans-Christer
2009-01-01
Double poling (DP) as a main technique in cross-country skiing has developed substantially over the last 15 yr. The purpose of the present study was to analyze the question, "How do modern elite skiers control DP speed?" Twelve male elite cross-country skiers roller skied using DP at 9, 15, 21, and 27 km.h(-1) and maximum velocity (V(max)). Cycle characteristics, pole and plantar forces, and elbow, hip, and knee joint angles were analyzed. Both poling frequency and cycle length increased up to 27 km.h (-1)(P < 0.05), with a further increase in poling frequency at V(max) (P < 0.05). Peak pole force, rate of force development, and rearfoot plantar force increased with submaximal velocities (V(sm)), whereas poling time and time-to-peak pole force gradually shortened (P < 0.05). Changes in elbow joint kinematics during the poling phase were characterized by a decreased angle minimum and an increased flexion and extension ranges of motion as well as angular velocities across V(sm) (P < 0.05), with no further changes at V(max). Hip and knee joint kinematics adapted across V(sm) by 1) decreasing angles at pole plant and angle minima during the poling phase, 2) increasing the ranges of motion and angular velocities during the flexion phases occurring around pole plant, and 3) increasing extension ranges of motion and angular velocities during the recovery phase (all P values <0.05), with no further changes at V(max). Elite skiers control DP speed by increasing both poling frequency and cycle length; the latter is achieved by increased pole force despite reduced poling time. Adaptation to higher speeds was assisted by an increased range of motion, smaller angle minima, and higher angular velocities in the elbow, the hip, and the knee joints.
Kim, Abraham D; Shah, Vivek M; Scott, Richard D
2016-05-01
We evaluated the intraoperative effect of patellar thickness on intraoperative passive knee flexion and patellar tracking during total knee arthroplasty (TKA) in patients with preoperative arthrofibrosis and compared them to patients with normal preoperative range of motion (ROM) documented in a prior study. Routine posterior cruciate ligament-retaining TKA was performed in a total of 34 knees, 23 with normal ROM and 11 with arthrofibrosis, defined as ≤100° of passive knee flexion against gravity under anesthesia. Once clinical balance and congruent patellar tracking were established, custom trial patellar components thicker than the standard trial by 2-mm increments (2-8 mm) were sequentially placed and trialed. Passive flexion against gravity was recorded using digital photograph goniometry. Gross mechanics of patellofemoral tracking were visually assessed. On average, passive knee flexion decreased 2° for every 2-mm increment of patellar thickness (P < .0001), which was similar to patients with normal preoperative ROM. In addition, increased patellar thickness had no gross effect on patellar subluxation and tilt in patients with arthrofibrosis as well as those with normal ROM. Patellar thickness had a modest effect on intraoperative passive flexion and no effect on patellar tracking in patients with arthrofibrosis undergoing TKA. There was no marked difference in intraoperative flexion and patellar tracking between patients with arthrofibrosis and patients with normal preoperative ROM. Copyright © 2016 Elsevier Inc. All rights reserved.
Knee Muscular Control During Jump Landing in Multidirections.
Sinsurin, Komsak; Vachalathiti, Roongtiwa; Jalayondeja, Wattana; Limroongreungrat, Weerawat
2016-06-01
Jump landing is a complex movement in sports. While competing and practicing, athletes frequently perform multi-planar jump landing. Anticipatory muscle activity could influence the amount of knee flexion and prepare the knee for dynamic weight bearing such as landing tasks. The aim of the present study was to examine knee muscle function and knee flexion excursion as athletes naturally performed multi-direction jump landing. Eighteen male athletes performed the jump-landing test in four directions: forward (0°), 30° diagonal, 60° diagonal, and lateral (90°). Muscles tested were vastus medialis (VM), vastus lateralis (VL), rectus femoris (RF), semitendinosus (ST), and biceps femoris (BF). A Vicon(TM) 612 workstation collected the kinematic data. An electromyography was synchronized with the Vicon(TM) Motion system to quantify dynamic muscle function. Repeated measure ANOVA was used to analyze the data. Jump-landing direction significantly influenced (P < 0.05) muscle activities of VL, RF, and ST and knee flexion excursion. Jumpers landed with a trend of decreasing knee flexion excursion and ST muscle activity 100 ms before foot contact progressively from forward to lateral directions of jump landing. A higher risk of knee injury might occur during lateral jump landing than forward and diagonal directions. Athletes should have more practice in jump landing in lateral direction to avoid injury. Landing technique with high knee flexion in multi-directions should be taught to jumpers for knee injury prevention.
Geeslin, Andrew G; Chahla, Jorge; Moatshe, Gilbert; Muckenhirn, Kyle J; Kruckeberg, Bradley M; Brady, Alex W; Coggins, Ashley; Dornan, Grant J; Getgood, Alan M; Godin, Jonathan A; LaPrade, Robert F
2018-05-01
The individual kinematic roles of the anterolateral ligament (ALL) and the distal iliotibial band Kaplan fibers in the setting of anterior cruciate ligament (ACL) deficiency require further clarification. This will improve understanding of their potential contribution to residual anterolateral rotational laxity after ACL reconstruction and may influence selection of an anterolateral extra-articular reconstruction technique, which is currently a matter of debate. Hypothesis/Purpose: To compare the role of the ALL and the Kaplan fibers in stabilizing the knee against tibial internal rotation, anterior tibial translation, and the pivot shift in ACL-deficient knees. We hypothesized that the Kaplan fibers would provide greater tibial internal rotation restraint than the ALL in ACL-deficient knees and that both structures would provide restraint against internal rotation during a simulated pivot-shift test. Controlled laboratory study. Ten paired fresh-frozen cadaveric knees (n = 20) were used to investigate the effect of sectioning the ALL and the Kaplan fibers in ACL-deficient knees with a 6 degrees of freedom robotic testing system. After ACL sectioning, sectioning was randomly performed for the ALL and the Kaplan fibers. An established robotic testing protocol was utilized to assess knee kinematics when the specimens were subjected to a 5-N·m internal rotation torque (0°-90° at 15° increments), a simulated pivot shift with 10-N·m valgus and 5-N·m internal rotation torque (15° and 30°), and an 88-N anterior tibial load (30° and 90°). Sectioning of the ACL led to significantly increased tibial internal rotation (from 0° to 90°) and anterior tibial translation (30° and 90°) as compared with the intact state. Significantly increased internal rotation occurred with further sectioning of the ALL (15°-90°) and Kaplan fibers (15°, 60°-90°). At higher flexion angles (60°-90°), sectioning the Kaplan fibers led to significantly greater internal rotation when compared with ALL sectioning. On simulated pivot-shift testing, ALL sectioning led to significantly increased internal rotation and anterior translation at 15° and 30°; sectioning of the Kaplan fibers led to significantly increased tibial internal rotation at 15° and 30° and anterior translation at 15°. No significant difference was found when anterior tibial translation was compared between the ACL/ALL- and ACL/Kaplan fiber-deficient states on simulated pivot-shift testing or isolated anterior tibial load. The ALL and Kaplan fibers restrain internal rotation in the ACL-deficient knee. Sectioning the Kaplan fibers led to greater tibial internal rotation at higher flexion angles (60°-90°) as compared with ALL sectioning. Additionally, the ALL and Kaplan fibers contribute to restraint of the pivot shift and anterior tibial translation in the ACL-deficient knee. This study reports that the ALL and distal iliotibial band Kaplan fibers restrain anterior tibial translation, internal rotation, and pivot shift in the ACL-deficient knee. Furthermore, sectioning the Kaplan fibers led to significantly greater tibial internal rotation when compared with ALL sectioning at high flexion angles. These results demonstrate increased rotational knee laxity with combined ACL and anterolateral extra-articular knee injuries and may allow surgeons to optimize the care of patients with this injury pattern.
NASA Astrophysics Data System (ADS)
Barki, Anum; Kendricks, Kimberly; Tuttle, Ronald F.; Bunker, David J.; Borel, Christoph C.
2013-05-01
This research highlights the results obtained from applying the method of inverse kinematics, using Groebner basis theory, to the human gait cycle to extract and identify lower extremity gait signatures. The increased threat from suicide bombers and the force protection issues of today have motivated a team at Air Force Institute of Technology (AFIT) to research pattern recognition in the human gait cycle. The purpose of this research is to identify gait signatures of human subjects and distinguish between subjects carrying a load to those subjects without a load. These signatures were investigated via a model of the lower extremities based on motion capture observations, in particular, foot placement and the joint angles for subjects affected by carrying extra load on the body. The human gait cycle was captured and analyzed using a developed toolkit consisting of an inverse kinematic motion model of the lower extremity and a graphical user interface. Hip, knee, and ankle angles were analyzed to identify gait angle variance and range of motion. Female subjects exhibited the most knee angle variance and produced a proportional correlation between knee flexion and load carriage.
Transverse Stress Fracture of the Proximal Patella: A Case Report.
Atsumi, Satoru; Arai, Yuji; Kato, Ko; Nishimura, Akinobu; Nakazora, Shigeto; Nakagawa, Shuji; Ikoma, Kazuya; Fujiwara, Hiroyoshi; Sudo, Akihiro; Kubo, Toshikazu
2016-02-01
Among stress fractures associated with sports activities, patellar stress fracture is rare. Regarding patella stress fractures, so far only distal transverse or lateral longitudinal fractures have been reported, but there are no reports of transverse fractures occurring in the proximal patella. We describe an extremely rare case of transverse stress fracture of proximal patella in a 9-year-old athlete.A 9-year old boy, who participated in sports (sprints and Kendo) presented with left knee pain without any external injury. In plain radiographs, a fracture line was observed in the proximal 1/3 of the left patella, and a patella stress fracture was diagnosed. For treatment, because 7 months of conservative therapy showed no improvement, internal fixation was carried out using Acutrak screws, and bone union was thus achieved. Three months after the operation, he was able to return to his previous level of athletic sports activity.Regarding the mechanism of onset, it is believed that the causes are longitudinal traction force and patellofemoral contact pressure. On the other hand, the contact region of the patella with the femur changes with the flexion angle of the knee. In the current case, the fracture occurred at a site where the patella was in contact with the femur at a flexion angle of >90°, so it is believed that it occurred as a clinical condition from being subjected to repeated longitudinal traction force and patellofemoral contact pressure at a flexion angle of >90°, during the sports activities of sprints and Kendo. The nonunion of the transverse stress fracture of his proximal patella was successfully treated with internal fixation using Acutrak screws.
Transverse Stress Fracture of the Proximal Patella
Atsumi, Satoru; Arai, Yuji; Kato, Ko; Nishimura, Akinobu; Nakazora, Shigeto; Nakagawa, Shuji; Ikoma, Kazuya; Fujiwara, Hiroyoshi; Sudo, Akihiro; Kubo, Toshikazu
2016-01-01
Abstract Among stress fractures associated with sports activities, patellar stress fracture is rare. Regarding patella stress fractures, so far only distal transverse or lateral longitudinal fractures have been reported, but there are no reports of transverse fractures occurring in the proximal patella. We describe an extremely rare case of transverse stress fracture of proximal patella in a 9-year-old athlete. A 9-year old boy, who participated in sports (sprints and Kendo) presented with left knee pain without any external injury. In plain radiographs, a fracture line was observed in the proximal 1/3 of the left patella, and a patella stress fracture was diagnosed. For treatment, because 7 months of conservative therapy showed no improvement, internal fixation was carried out using Acutrak screws, and bone union was thus achieved. Three months after the operation, he was able to return to his previous level of athletic sports activity. Regarding the mechanism of onset, it is believed that the causes are longitudinal traction force and patellofemoral contact pressure. On the other hand, the contact region of the patella with the femur changes with the flexion angle of the knee. In the current case, the fracture occurred at a site where the patella was in contact with the femur at a flexion angle of >90°, so it is believed that it occurred as a clinical condition from being subjected to repeated longitudinal traction force and patellofemoral contact pressure at a flexion angle of >90°, during the sports activities of sprints and Kendo. The nonunion of the transverse stress fracture of his proximal patella was successfully treated with internal fixation using Acutrak screws. PMID:26871789
Angular-velocity control approach for stance-control orthoses.
Lemaire, Edward D; Goudreau, Louis; Yakimovich, Terris; Kofman, Jonathan
2009-10-01
Currently, stance-control knee orthoses require external control mechanisms to control knee flexion during stance and allow free knee motion during the swing phase of gait. A new angular-velocity control approach that uses a rotary-hydraulic device to resist knee flexion when the knee angular velocity passes a preset threshold is presented. This angular-velocity approach for orthotic stance control is based on the premise that knee-flexion angular velocity during a knee-collapse event, such as a stumble or fall, is greater than that during walking. The new hydraulic knee-flexion control device does not require an external control mechanism to switch from free motion to stance control mode. Functional test results demonstrated that the hydraulic angular-velocity activated knee joint provided free knee motion during walking, engaged upon knee collapse, and supported body weight while the end-user recovered to a safe body position. The joint was tested to 51.6 Nm in single loading tests and passed 200,000 repeated loading cycles with a peak load of 88 Nm per cycle. The hydraulic, angular velocity activation approach has potential to improve safety and security for people with lower extremity weakness or when recovering from joint trauma.
Olstad, Bjørn Harald; Vaz, João Rocha; Zinner, Christoph; Cabri, Jan M H; Kjendlie, Per-Ludvik
2017-06-01
The aims of this study were to describe muscular activation patterns and kinematic variables during the complete stroke cycle (SC) and the different phases of breaststroke swimming at submaximal and maximal efforts. Surface electromyography (sEMG) was collected from eight muscles in nine elite swimmers; five females (age 20.3 ± 5.4 years; Fédération Internationale de Natation [FINA] points 815 ± 160) and four males (27.7 ± 7.1 years; FINA points 879 ± 151). Underwater cameras were used for 3D kinematic analysis with automatic motion tracking. The participants swam 25 m of breaststroke at 60%, 80% and 100% effort and each SC was divided into three phases: knee extension, knee extended and knee flexion. With increasing effort, the swimmers decreased their SC distance and increased their velocity and stroke rate. A decrease during the different phases was found for duration during knee extended and knee flexion, distance during knee extended and knee angle at the beginning of knee extension with increasing effort. Velocity increased for all phases. The mean activation pattern remained similar across the different effort levels, but the muscles showed longer activation periods relative to the SC and increased integrated sEMG (except trapezius) with increasing effort. The muscle activation patterns, muscular participation and kinematics assessed in this study with elite breaststroke swimmers contribute to a better understanding of the stroke and what occurs at different effort levels. This could be used as a reference for optimising breaststroke training to improve performance.
Dual-joint modeling for estimation of total knee replacement contact forces during locomotion.
Hast, Michael W; Piazza, Stephen J
2013-02-01
Model-based estimation of in vivo contact forces arising between components of a total knee replacement is challenging because such forces depend upon accurate modeling of muscles, tendons, ligaments, contact, and multibody dynamics. Here we describe an approach to solving this problem with results that are tested by comparison to knee loads measured in vivo for a single subject and made available through the Grand Challenge Competition to Predict in vivo Tibiofemoral Loads. The approach makes use of a "dual-joint" paradigm in which the knee joint is alternately represented by (1) a ball-joint knee for inverse dynamic computation of required muscle controls and (2) a 12 degree-of-freedom (DOF) knee with elastic foundation contact at the tibiofemoral and patellofemoral articulations for forward dynamic integration. Measured external forces and kinematics were applied as a feedback controller and static optimization attempted to track measured knee flexion angles and electromyographic (EMG) activity. The resulting simulations showed excellent tracking of knee flexion (average RMS error of 2.53 deg) and EMG (muscle activations within ±10% envelopes of normalized measured EMG signals). Simulated tibiofemoral contact forces agreed qualitatively with measured contact forces, but their RMS errors were approximately 25% of the peak measured values. These results demonstrate the potential of a dual-joint modeling approach to predict joint contact forces from kinesiological data measured in the motion laboratory. It is anticipated that errors in the estimation of contact force will be reduced as more accurate subject-specific models of muscles and other soft tissues are developed.
Scuderi, Giles R; Hedden, David R; Maltry, John A; Traina, Steven M; Sheinkop, Mitchell B; Hartzband, Mark A
2012-03-01
Between May 2001 and June 2004, 388 total knee arthroplasty cases were enrolled in a prospective, randomized, multicenter investigational device exemption trial. Patients received either the investigational high-flexion mobile-bearing knee or a fixed-bearing control. At 2 to 4 years of follow-up, results in 293 patients with degenerative joint disease were compared using Knee Society Assessment and Function scores, radiographic results, complications analysis, and survival estimates. The mobile-bearing and fixed-bearing groups demonstrated similar, significant improvement over preoperative assessments in Knee Scores, maximum flexion, and range of motion. One mobile-bearing arthroplasty required revision. Radiographic results were unremarkable, and implant-related complications were rare in both groups. At this early follow-up, the investigational high-flexion mobile-bearing knee and its fixed-bearing counterpart demonstrated comparable, effective performance. Copyright © 2012 Elsevier Inc. All rights reserved.
Wound closure in flexion versus extension following total knee arthroplasty: a systematic review.
Smith, Toby O; Davies, Leigh; Hing, Caroline B
2010-06-01
Optimising knee range of motion following total knee arthroplasty (TKA) is important for patient satisfaction, functional outcome and early rehabilitation to promote accelerated discharge. Historically, wound closure following TKA has been performed in extension. It has been suggested that knee position during wound closure may influence range of motion and clinical outcomes following TKA. The purpose of this study was to determine whether TKA wounds should be closed in flexion or extension. An electronic search of MEDLINE, EMBASE, CINAHL and AMED databases was made in addition to a review of unpublished material. All included papers were critically appraised using a modified PEDro (Physiotherapy Evidence Database) critical appraisal tool. Three papers were eligible, assessing 237 TKAs. On analysis, patients with TKA wounds closed in flexion had greater flexion range of motion and required less domiciliary physiotherapy compared to those with wounds closed in full extension. The specific degree of knee flexion used when closing total knee replacement wounds may be an important variable to clinical outcome. However, the present evidence-base is limited in both size and methodological quality.
Wu, Yuangang; Yang, Timin; Zeng, Yi; Si, Haibo; Li, Canfeng; Shen, Bin
2017-01-01
Postoperative limb positioning has been reported to be an efficient and simple way to reduce blood loss and improve range of motion following total knee arthroplasty (TKA). This meta-analysis was designed to compare the effectiveness of two different limb positions in primary TKA. A meta-analysis of the PubMed, CENTRAL, Web of Science, EMBASE and Google Search Engine electronic databases was performed. In this meta-analysis, two postoperative limb positions were considered: mild-flexion (flexion less than 60°) and high-flexion (flexion at 60° or more). The subgroups were analysed using RevMan 5.3. Nine RCTs were included with a total sample size of 913 patients. The mild- and high-flexion positions significantly reduced postoperative total blood loss (P = 0.04 and P = 0.01; respectively). Subgroup analysis indicated that knee flexion significantly reduced hidden blood loss when the knee was fixed in mild-flexion (P = 0.0004) and significantly reduced transfusion requirements (P = 0.03) and improved range of motion (ROM) (P < 0.00001) when the knee was fixed in high-flexion. However, the rates of wound-related infection, deep venous thrombosis (DVT) and pulmonary embolism (PE) did not significantly differ between the two flexion groups. This meta-analysis suggests that mild- and high-flexion positions have similar efficacy in reducing total blood loss. In addition, subgroup analysis indicates that the mild-flexion position is superior in decreasing hidden blood loss compared with high-flexion; the high-flexion position is superior to mild-flexion in reducing transfusion requirements and improving postoperative ROM. Thus, the use of the high-flexion position is a viable option to reduce blood loss in patients following primary TKA without increasing the risk of wound-related infection, DVT or PE. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
Silva, Danilo de Oliveira; Briani, Ronaldo Valdir; Pazzinatto, Marcella Ferraz; Ferrari, Deisi; Aragão, Fernando Amâncio; Azevedo, Fábio Mícolis de
2015-11-01
Stair ascent is an activity that exacerbates symptoms of individuals with patellofemoral pain. The discomfort associated with this activity usually results in gait modification such as reduced knee flexion in an attempt to reduce pain. Although such compensatory strategy is a logical approach to decrease pain, it also reduces the normal active shock absorption increasing loading rates and may lead to deleterious and degenerative changes of the knee joint. Thus, the aims of this study were (i) to investigate whether there is reduced knee flexion in adults with PFP compared to healthy controls; and (ii) to analyze loading rates in these subjects, during stair climbing. Twenty-nine individuals with patellofemoral pain and twenty-five control individuals (18-30 years) participated in this study. Each subject underwent three-dimensional kinematic and kinetic analyses during stair climbing on two separate days. Between-groups analyses of variance were performed to identify differences in peak knee flexion and loading rates. Intraclass correlation coefficient was performed to verify the reliability of the variables. On both days, the patellofemoral pain group demonstrated significantly reduced peak knee flexion and increased loading rates. In addition, the two variables obtained high to very high reliability. Reduced knee flexion during stair climbing as a strategy to avoid anterior knee pain does not seem to be healthy for lower limb mechanical distributions. Repeated loading at higher loading rates may be damaging to lower limb joints. Copyright © 2015 Elsevier Ltd. All rights reserved.
Rossi, Stefano; Colazza, Alessandra; Petrarca, Maurizio; Castelli, Enrico; Cappa, Paolo; Krebs, Hermano Igo
2013-01-01
We are designing a pediatric exoskeletal ankle robot (pediatric Anklebot) to promote gait habilitation in children with Cerebral Palsy (CP). Few studies have evaluated how much or whether the unilateral loading of a wearable exoskeleton may have the unwanted effect of altering significantly the gait. The purpose of this study was to evaluate whether adding masses up to 2.5 kg, the estimated overall added mass of the mentioned device, at the knee level alters the gait kinematics. Ten healthy children and eight children with CP, with light or mild gait impairment, walked wearing a knee brace with several masses. Gait parameters and lower-limb joint kinematics were analyzed with an optoelectronic system under six conditions: without brace (natural gait) and with masses placed at the knee level (0.5, 1.0, 1.5, 2.0, 2.5 kg). T-tests and repeated measures ANOVA tests were conducted in order to find noteworthy differences among the trial conditions and between loaded and unloaded legs. No statistically significant differences in gait parameters for both healthy children and children with CP were observed in the five “with added mass” conditions. We found significant differences among “natural gait” and “with added masses” conditions in knee flexion and hip extension angles for healthy children and in knee flexion angle for children with CP. This result can be interpreted as an effect of the mechanical constraint induced by the knee brace rather than the effect associated with load increase. The study demonstrates that the mechanical constraint induced by the brace has a measurable effect on the gait of healthy children and children with CP and that the added mass up to 2.5 kg does not alter the lower limb kinematics. This suggests that wearable devices weighing 25 N or less will not noticeably modify the gait patterns of the population examined here. PMID:24023822
Rossi, Stefano; Colazza, Alessandra; Petrarca, Maurizio; Castelli, Enrico; Cappa, Paolo; Krebs, Hermano Igo
2013-01-01
We are designing a pediatric exoskeletal ankle robot (pediatric Anklebot) to promote gait habilitation in children with Cerebral Palsy (CP). Few studies have evaluated how much or whether the unilateral loading of a wearable exoskeleton may have the unwanted effect of altering significantly the gait. The purpose of this study was to evaluate whether adding masses up to 2.5 kg, the estimated overall added mass of the mentioned device, at the knee level alters the gait kinematics. Ten healthy children and eight children with CP, with light or mild gait impairment, walked wearing a knee brace with several masses. Gait parameters and lower-limb joint kinematics were analyzed with an optoelectronic system under six conditions: without brace (natural gait) and with masses placed at the knee level (0.5, 1.0, 1.5, 2.0, 2.5 kg). T-tests and repeated measures ANOVA tests were conducted in order to find noteworthy differences among the trial conditions and between loaded and unloaded legs. No statistically significant differences in gait parameters for both healthy children and children with CP were observed in the five "with added mass" conditions. We found significant differences among "natural gait" and "with added masses" conditions in knee flexion and hip extension angles for healthy children and in knee flexion angle for children with CP. This result can be interpreted as an effect of the mechanical constraint induced by the knee brace rather than the effect associated with load increase. The study demonstrates that the mechanical constraint induced by the brace has a measurable effect on the gait of healthy children and children with CP and that the added mass up to 2.5 kg does not alter the lower limb kinematics. This suggests that wearable devices weighing 25 N or less will not noticeably modify the gait patterns of the population examined here.
Rice, David Andrew; McNair, Peter John; Lewis, Gwyn Nancy; Dalbeth, Nicola
2015-07-28
Substantial weakness of the quadriceps muscles is typically observed in patients with arthritis. This is partly due to ongoing neural inhibition that prevents the quadriceps from being fully activated. Evidence from animal studies suggests enhanced flexion reflex excitability may contribute to this weakness. This prospective observational study examined the effects of joint aspiration and intra-articular corticosteroid injection on flexion reflex excitability, quadriceps muscle strength and knee pain in individuals with knee synovitis. Sixteen patients with chronic arthritis and clinically active synovitis of the knee participated in this study. Knee pain flexion reflex threshold, and quadriceps peak torque were measured at baseline, immediately after knee joint aspiration alone and 5 ± 2 and 15 ± 2 days after knee joint aspiration and the injection of 40 mg of methylprednisolone acetate. Compared to baseline, knee pain was significantly reduced 5 (p = 0.001) and 15 days (p = 0.009) post intervention. Flexion reflex threshold increased immediately after joint aspiration (p = 0.009) and 5 (p = 0.01) and 15 days (p = 0.002) post intervention. Quadriceps peak torque increased immediately after joint aspiration (p = 0.004) and 5 (p = 0.001) and 15 days (p <0.001) post intervention. The findings from this study suggest that altered sensory output from an inflamed joint may increase flexion reflex excitability in humans, as has previously been shown in animals. Joint aspiration and corticosteroid injection may be a clinically useful intervention to reverse quadriceps muscle weakness in individuals with knee synovitis.
Brown, T N; O'Donovan, M; Hasselquist, L; Corner, B; Schiffman, J M
2016-01-01
Fifteen military personnel performed 30-cm drop landings to quantify how body borne load (light, ∼6 kg, medium, ∼20 kg, and heavy, ∼40 kg) impacts lower limb kinematics and knee joint energy absorption during landing, and determine whether greater lower limb flexion increases energy absorption while landing with load. Participants decreased peak hip (P = 0.002), and knee flexion (P = 0.007) posture, but did not increase hip (P = 0.796), knee (P = 0.427) or ankle (P = 0.161) energy absorption, despite exhibiting greater peak hip (P = 0.003) and knee (P = 0.001) flexion, and ankle (P = 0.003) dorsiflexion angular impulse when landing with additional load. Yet, when landing with the light and medium loads, greater hip (R(2) = 0.500, P = 0.003 and R(2) = 0.314, P = 0.030) and knee (R(2) = 0.431, P = 0.008 and R(2) = 0.342, P = 0.022) flexion posture predicted larger knee joint energy absorption. Thus, military training that promotes hip and knee flexion, and subsequently greater energy absorption during landing, may potentially reduce risk of musculoskeletal injury and optimize soldier performance. Published by Elsevier Ltd.
The Anterolateral Capsule of the Knee Behaves Like a Sheet of Fibrous Tissue.
Guenther, Daniel; Rahnemai-Azar, Amir A; Bell, Kevin M; Irarrázaval, Sebastián; Fu, Freddie H; Musahl, Volker; Debski, Richard E
2017-03-01
The function of the anterolateral capsule of the knee has not been clearly defined. However, the contribution of this region of the capsule to knee stability in comparison with other anterolateral structures can be determined by the relative force that each structure carries during loading of the knee. Purpose/Hypothesis: The purpose of this study was to determine the forces in the anterolateral structures of the intact and anterior cruciate ligament (ACL)-deficient knee in response to an anterior tibial load and internal tibial torque. It was hypothesized that the anterolateral capsule would not function like a traditional ligament (ie, transmitting forces only along its longitudinal axis). Controlled laboratory study. Loads (134-N anterior tibial load and 7-N·m internal tibial torque) were applied continuously during flexion to 7 fresh-frozen cadaveric knees in the intact and ACL-deficient state using a robotic testing system. The lateral collateral ligament (LCL) and the anterolateral capsule were separated from the surrounding tissue and from each other. This was done by performing 3 vertical incisions: lateral to the LCL, medial to the LCL, and lateral to the Gerdy tubercle. Attachments of the LCL and anterolateral capsule were detached from the underlying tissue (ie, meniscus), leaving the insertions and origins intact. The force distribution in the anterolateral capsule, ACL, and LCL was then determined at 30°, 60°, and 90° of knee flexion using the principle of superposition. In the intact knee, the force in the ACL in response to an anterior tibial load was greater than that in the other structures ( P < .001). However, in response to an internal tibial torque, no significant differences were found between the ACL, LCL, and forces transmitted between each region of the anterolateral capsule after capsule separation. The anterolateral capsule experienced smaller forces (~50% less) compared with the other structures ( P = .048). For the ACL-deficient knee in response to an anterior tibial load, the force transmitted between each region of the anterolateral capsule was 434% greater than was the force in the anterolateral capsule ( P < .001) and 54% greater than the force in the LCL ( P = .036) at 30° of flexion. In response to an internal tibial torque at 30°, 60°, or 90° of knee flexion, no significant differences were found between the force transmitted between each region of the anterolateral capsule and the LCL. The force in the anterolateral capsule was significantly smaller than that in the other structures at all knee flexion angles for both loading conditions ( P = .004 for anterior tibial load and P = .04 for internal tibial torque). The anterolateral capsule carries negligible forces in the longitudinal direction, and the forces transmitted between regions of the capsule were similar to the forces carried by the other structures at the knee, suggesting that it does not function as a traditional ligament. Thus, the anterolateral capsule should be considered a sheet of tissue. Surgical repair techniques for the anterolateral capsule should restore the ability of the tissue to transmit forces between adjacent regions of the capsule rather than along its longitudinal axis.
Alterations in neuromuscular function in girls with generalized joint hypermobility.
Jensen, Bente Rona; Sandfeld, Jesper; Melcher, Pia Sandfeld; Johansen, Katrine Lyders; Hendriksen, Peter; Juul-Kristensen, Birgit
2016-10-03
Generalized Joint Hypermobility (GJH) is associated with increased risk of musculoskeletal joint pain. We investigated neuromuscular performance and muscle activation strategy. Girls with GJH and non-GJH (NGJH) performed isometric knee flexions (90°,110°,130°), and extensions (90°) at 20 % Maximum Voluntary Contraction, and explosive isometric knee flexions while sitting. EMG was recorded from knee flexor and extensor muscles. Early rate of torque development was 53 % faster for GJH. Reduced hamstring muscle activation in girls with GJH was found while knee extensor and calf muscle activation did not differ between groups. Flexion-extension and medial-lateral co-activation ratio during flexions were higher for girls with GJH than NGJH girls. Girls with GJH had higher capacity to rapidly generate force than NGJH girls which may reflect motor adaptation to compensate for hypermobility. Higher medial muscle activation indicated higher levels of medial knee joint compression in girls with GJH. Increased flexion-extension co-activation ratios in GJH were explained by decreased agonist drive to the hamstrings.
Mullaji, Arun; Sharma, Amit; Marawar, Satyajit; Kanna, Raj
2009-08-01
A novel sequence of posteromedial release consistent with surgical technique of total knee arthroplasty was performed in 15 cadaveric knees. Medial and lateral flexion and extension gaps were measured after each step of the release using a computed tomography-free computer navigation system. A spring-loaded distractor and a manual distractor were used to distract the joint. Posterior cruciate ligament release increased flexion more than extension gap; deep medial collateral ligament release had a negligible effect; semimembranosus release increased the flexion gap medially; reduction osteotomy increased medial flexion and extension gaps; superficial medial collateral ligament release increased medial joint gap more in flexion and caused severe instability. This sequence of release led to incremental and differential effects on flexion-extension gaps and has implications in correcting varus deformity.
Wang, Xingshan; Weng, Xisheng; Lin, Jin; Jin, Jin; Qian, Wenwei
2012-05-01
To investigate the surgical technique and the clinical results of total knee arthroplasty (TKA) in treating end-stage gonarthrosis combined with valgus knee deformity. Between November 1998 and October 2010, 64 patients (72 knees) with end-stage gonarthrosis combined with valgus knee deformity underwent TKA by a medial parapatellar approach. Of the 64 patients, 18 were male and 46 were female with an average age of 62.5 years (range, 23-82 years), including 44 cases (49 knees) of osteoarthritis, 17 cases (20 knees) of rheumatoid arthritis, 2 cases (2 knees) of haemophilic arthritis, and 1 case (1 knee) of post-traumatic arthritis. Bilateral knees were involved in 8 cases, and single knee in 56 cases. The flexion and extension range of motion (ROM) of the knee joint was (82.2 +/- 28.7) degrees; the femur-tibia angle (FTA) was (18.0 +/- 5.8) degrees; according to Knee Society Score (KSS) criterion, the preoperative clinical score was 31.2 +/- 10.1 and functional score was 37.3 +/- 9.0. According to Krackow's classification, there were 65 knees of type I and 7 knees of type II. By medial parapatellar approach, conventional osteotomy and Ranawat soft tissue release were performed in all cases. Prosthesis of preserved posterior cruciate ligament were used in 7 cases (7 knees), posterior stabilize prosthesis in 54 cases (60 knees), constrained prosthesis in 4 cases (5 knees). Incisions healed by first intention in all cases. Peroneal nerve palsy occurred in 1 patient with haemophilic arthritis, severe valgus deformity (FTA was 41 degrees), and flexion contracture (20 degrees), which was cured after 1 year of conservative treatment. Revison surgery was performed in 1 case of deep infection at 2 years after surgery. All the patients were followed up 4.9 years on average (range, 1-13 years). At last follow-up, the FTA was (7.0 +/- 2.5) degrees, showing significant difference when compared with preoperative value (t = 15.502, P = 0.000). The KSS clinical score was 83.0 +/- 6.6 and functional score was 85.1 +/- 10.5, the flexion and extension ROM of the knee joint was (106.1 +/- 17.0) degrees, all showing significant differences when compared with preoperative values (P < 0.05). Five patients had 12-15 degrees valgus knee deformity, but the function of the affect knees were good. TKA is an effective way for the patients with end-stage gonarthrosis combined with valgus knee deformity by medial parapatellar approach combined with conventional osteotomy and Ranawat soft tissue release. The correction of deformity and improvement of joint function can be achieved significantly. The clinical result is satisfactory.
Niki, Yasuo; Harato, Kengo; Nagai, Katsuya; Suda, Yasunori; Nakamura, Masaya; Matsumoto, Morio
2015-12-01
This study aimed to assess the effects of down-sizing and lateralizing of the tibial component (reduction osteotomy) on gap balancing in TKA, and the clinical feasibility of an uncemented modular trabecular metal tibial tray in this technique. Reduction osteotomy was performed for 39 knees of 36 patients with knee OA with a mean tibiofemoral angle of 21° varus. In 20 knees, appropriate gap balance was achieved by release of the deep medial collateral ligament alone. Flexion gap imbalance could be reduced by approximately 1.7° and 2.8° for 4-mm osteotomy and 8-mm osteotomy, respectively. Within the first postoperative year, clinically-stable tibial component subsidence was observed in 9 knees, but it was not progressive, and the clinical results were excellent at a mean follow-up of 3.3 years. Copyright © 2015 Elsevier Inc. All rights reserved.
Relationship of spasticity to knee angular velocity and motion during gait in cerebral palsy.
Damiano, Diane L; Laws, Edward; Carmines, Dave V; Abel, Mark F
2006-01-01
This study investigated the effects of spasticity in the hamstrings and quadriceps muscles on gait parameters including temporal spatial measures, knee position, excursion and angular velocity in 25 children with spastic diplegic cerebral palsy (CP) as compared to 17 age-matched peers. While subjects were instructed to relax, an isokinetic device alternately flexed and extended the left knee at one of the three constant velocities 30 degrees/s, 60 degrees/s and 120 degrees/s, while surface electromyography (EMG) electrodes over the biceps femoris and the rectus femoris recorded muscle activity. Patients then participated in 3D gait analysis at a self-selected speed. Results showed that, those with CP who exhibited heightened stretch responses (spasticity) in both muscles, had significantly slower knee angular velocities during the swing phase of gait as compared to those with and without CP who did not exhibit stretch responses at the joint and the tested speeds. The measured amount (torque) of the resistance to passive flexion or extension was not related to gait parameters in subjects with CP; however, the rate of change in resistance torque per unit angle change (stiffness) at the fastest test speed of 120 degrees/s showed weak to moderate relationships with knee angular velocity and motion during gait. For the subset of seven patients with CP who subsequently underwent a selective dorsal rhizotomy, knee angular extension and flexion velocity increased post-operatively, suggesting some degree of causality between spasticity and movement speed.
The effect of spinal manipulation on imbalances in leg strength.
Chilibeck, Philip D; Cornish, Stephen M; Schulte, Al; Jantz, Nathan; Magnus, Charlene R A; Schwanbeck, Shane; Juurlink, Bernhard H J
2011-09-01
We hypothesized that spinal manipulation (SM) would reduce strength imbalances between legs. Using an un-blinded randomized design, 28 males and 21 females (54 ± 19y) with at least a 15% difference in isometric strength between legs for hip flexion, extension, abduction, or knee flexion were randomized to treatment or placebo (mock spinal manipulation). Strength of the stronger and weaker legs for hip flexion, extension, abduction, and/or knee flexion was assessed before and after the intervention. SM reduced the relative strength difference between legs for knee flexion (mean ± SD 57 ± 53 to 5 ± 14%) and hip flexion (24 ± 12 to 11 ± 15%) compared to placebo (34 ± 29 to 24 ± 36%, and 20 ± 18 to 22 ± 26%, respectively) (p = 0.05). SM also improved strength in the weak leg for hip abduction (104 ± 43 to 116 ± 43 Nm) compared to placebo (84 ± 24 to 85 ± 31 Nm) (p = 0.03). This study suggests that spinal manipulation may reduce imbalances in strength between legs for knee and hip flexion.
Rood, Akkie; Hannink, Gerjon; Lenting, Anke; Groenen, Karlijn; Koëter, Sander; Verdonschot, Nico; van Kampen, Albert
2015-10-01
Reconstructing the medial patellofemoral ligament (MPFL) has become a key procedure for stabilizing the patella. Different techniques to reconstruct the MPFL have been described: static techniques in which the graft is fixed rigidly to the bone or dynamic techniques with soft tissue fixation. Static MPFL reconstruction is most commonly used. However, dynamic reconstruction deforms more easily and presumably functions more like the native MPFL. The aim of the study was to evaluate the effect of the different MPFL fixation techniques on patellofemoral pressures compared with the native situation. The hypothesis was that dynamic reconstruction would result in patellofemoral pressures closer to those generated in an intact knee. Controlled laboratory study. Seven fresh-frozen knee specimens were tested in an in vitro knee joint loading apparatus. Tekscan pressure-sensitive films fixed to the retropatellar cartilage measured mean patellofemoral and peak pressures, contact area, and location of the center of force (COF) at fixed flexion angles from 0° to 110°. Four different conditions were tested: intact, dynamic, partial dynamic, and static MPFL reconstruction. Data were analyzed using linear mixed models. Static MPFL reconstruction resulted in higher peak and mean pressures from 60° to 110° of flexion (P < .001). There were no differences in pressure between the 2 different dynamic reconstructions and the intact situation (P > .05). The COF in the static reconstruction group moved more medially on the patella from 50° to 110° of flexion compared with the other conditions. The contact area showed no significant differences between the test conditions. After static MPFL reconstruction, the patellofemoral pressures in flexion angles from 60° to 110° were 3 to 5 times higher than those in the intact situation. The pressures after dynamic MPFL reconstruction were similar as compared with those in the intact situation, and therefore, dynamic MPFL reconstruction could be a safer option than static reconstruction for stabilizing the patella. This study showed that static MPFL reconstruction results in higher patellofemoral pressures and thus enhances the chance of osteoarthritis in the long term, while dynamic reconstruction results in more normal pressures. © 2015 The Author(s).
Minoda, Yukihide; Ikebuchi, Mitsuhiko; Mizokawa, Shigekazu; Ohta, Yoichi; Nakamura, Hiroaki
2016-11-01
Proper anteroposterior (AP) joint displacement is an important indicator of good clinical outcome following total knee arthroplasty (TKA). We hypothesized that a newly introduced mobile-bearing posterior stabilized (PS) prosthesis reduces the AP joint displacement. The aim of this study is to compare the AP joint displacement between a newly introduced mobile-bearing PS TKA in one knee and a conventional fixed-bearing PS TKA in other knee. 82 knees in 41 patients who had bilateral TKAs were investigated. All the patients received a conventional fixed-bearing PS prosthesis in one knee and a highly congruent mobile-bearing PS prosthesis in the other knee. AP joint displacement was measured using the KT-2000 arthrometer, at 30° and 75° in flexion, at average of 3.3 years after the operation. AP joint displacements at 30° in flexion were 6 ± 3 mm in the knees with the mobile-bearing PS prosthesis and 9 ± 4 mm in the knee with fixed-bearing PS prosthesis (p < 0.001). AP joint displacements at 75° in flexion were 4 ± 2 mm in the knees with the mobile-bearing PS prosthesis and 6 ± 3 mm in the knee with fixed-bearing PS prosthesis (p < 0.001). This study suggested that the design of the prosthesis can improve the AP joint stability in mid-flexion range.
Noehren, Brian; Davis, Irene; Hamill, Joseph
2007-11-01
Iliotibial band syndrome is the leading cause of lateral knee pain in runners. Despite its high prevalence, little is known about the biomechanics that lead to this syndrome. The purpose of this study was to prospectively compare lower extremity kinematics and kinetics between a group of female runners who develop iliotibial band syndrome compared to healthy controls. It was hypothesized that runners who develop iliotibial band syndrome will exhibit greater peak hip adduction, knee internal rotation, rearfoot eversion and no difference in knee flexion at heel strike. Additionally, the iliotibial band syndrome group were expected to have greater hip abduction, knee external rotation, and rearfoot inversion moments. A group of healthy female recreational runners underwent an instrumented gait analysis and were then followed for two years. Eighteen runners developed iliotibial band syndrome. Their initial running mechanics were compared to a group of age and mileage matched controls with no history of knee or hip pain. Comparisons of peak hip, knee, rearfoot angles and moments were made during the stance phase of running. Variables of interest were averaged over the five running trials, and then averaged across groups. The iliotibial band syndrome group exhibited significantly greater hip adduction and knee internal rotation. However, rearfoot eversion and knee flexion were similar between groups. There were no differences in moments between groups. The development of iliotibial band syndrome appears to be related to increased peak hip adduction and knee internal rotation. These combined motions may increase iliotibial band strain causing it to compress against the lateral femoral condyle. These data suggest that treatment interventions should focus on controlling these secondary plane movements through strengthening, stretching and neuromuscular re-education.
Comfort, Paul; Jones, Paul A; McMahon, John J; Newton, Robert
2015-01-01
The isometric midthigh pull (IMTP) has been used to monitor changes in force, maximum rate of force development (mRFD), and impulse, with performance in this task being associated with performance in athletic tasks. Numerous postures have been adopted in the literature, which may affect the kinetic variables during the task; therefore, the aim of this investigation was to determine whether different knee-joint angles (120°, 130°, 140°, and 150°) and hip-joint angles (125° and 145°), including the subjects preferred posture, affect force, mRFD, and impulse during the IMTP. Intraclass correlation coefficients demonstrated high within-session reliability (r ≥ .870, P < .001) for all kinetic variables determined in all postures, excluding impulse measures during the 130° knee-flexion, 125° hip-flexion posture, which showed a low to moderate reliability (r = .666-.739, P < .001), while between-sessions testing demonstrated high reliability (r > .819, P < .001) for all kinetic variables. There were no significant differences in peak force (P > .05, Cohen d = 0.037, power = .408), mRFD (P > .05, Cohen d = 0.037, power = .409), or impulse at 100 ms (P > .05, Cohen d = 0.056, power = .609), 200 ms (P > .05, Cohen d = 0.057, power = .624), or 300 ms (P > .05, Cohen d = 0.061, power = .656) across postures. Smallest detectable differences demonstrated that changes in performance of >1.3% in peak isometric force, >10.3% in mRFD, >5.3% in impulse at 100 ms, >4.4% in impulse at 200 ms, and >7.1% in impulse at 300 ms should be considered meaningful, irrespective of posture.
Comparison of the cable pin system with conventional open surgery for transverse patella fractures.
Mao, Ningfang; Liu, Deding; Ni, Haijian; Tang, Hao; Zhang, Qiulin
2013-07-01
The cable pin system is an effective device for fixation of transverse patella fractures. However, whether this device provides superior results using a minimally invasive technique instead of conventional open surgery using the K wire tension band method is unclear. We asked whether a minimally invasive technique would be associated with (1) increased operative time; (2) reduced postoperative pain; (3) faster recovery of ROM; (4) higher knee scores; and (5) reduced complications. Forty patients with displaced transverse fractures of the patella participated in this prospective, randomized, controlled trial. Twenty of these patients underwent a minimally invasive technique and the others had conventional open surgery using K wires. Some data for six of the 20 patients who underwent the minimally invasive technique were published in an earlier prospective, observational trial. At postoperative intervals of 1, 3, 6, 12, and 24 months, pain was measured by VAS scores, active flexion and extension of the knee were measured in degrees by goniometry, and knee function was evaluated using the Böstman clinical grading scale. Operative time was longer in the minimally invasive surgery group (54.3 ± 9.8 minutes versus 48.5 ± 6.1 minutes). Pain scores were better (lower) in the minimally invasive surgery group at 1 and 3 months but not at 6 months. Early flexion, ultimate flexion, and knee scores from 3 to 24 months, likewise, were better in the minimally invasive surgery group. Complications mostly related to symptomatic hardware were less common in the minimally invasive surgery group. The minimally invasive technique is superior to conventional open surgery using K wires in terms of less early postoperative pain, better mobility angles of the injured knee, higher functional score of the injured knee, and decreased incidence of complications. Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
An improved OpenSim gait model with multiple degrees of freedom knee joint and knee ligaments.
Xu, Hang; Bloswick, Donald; Merryweather, Andrew
2015-08-01
Musculoskeletal models are widely used to investigate joint kinematics and predict muscle force during gait. However, the knee is usually simplified as a one degree of freedom joint and knee ligaments are neglected. The aim of this study was to develop an OpenSim gait model with enhanced knee structures. The knee joint in this study included three rotations and three translations. The three knee rotations and mediolateral translation were independent, with proximodistal and anteroposterior translations occurring as a function of knee flexion/extension. Ten elastic elements described the geometrical and mechanical properties of the anterior and posterior cruciate ligaments (ACL and PCL), and the medial and lateral collateral ligaments (MCL and LCL). The three independent knee rotations were evaluated using OpenSim to observe ligament function. The results showed that the anterior and posterior bundles of ACL and PCL (aACL, pACL and aPCL, pPCL) intersected during knee flexion. The aACL and pACL mainly provided force during knee flexion and adduction, respectively. The aPCL was slack throughout the range of three knee rotations; however, the pPCL was utilised for knee abduction and internal rotation. The LCL was employed for knee adduction and rotation, but was slack beyond 20° of knee flexion. The MCL bundles were mainly used during knee adduction and external rotation. All these results suggest that the functions of knee ligaments in this model approximated the behaviour of the physical knee and the enhanced knee structures can improve the ability to investigate knee joint biomechanics during various gait activities.
A functional agility short-term fatigue protocol changes lower extremity mechanics
Cortes, Nelson; Quammen, David; Lucci, Shawn; Greska, Eric; Onate, James
2012-01-01
The purpose of this study was to evaluate the effects of a functional agility fatigue protocol on lower extremity biomechanics between two unanticipated tasks (stop-jump and sidestep). The subjects consisted of fifteen female collegiate soccer athletes (19 ± 0.7 years, 1.67 ± 0.1 m, 61.7 ± 8 kg) free of lower extremity injury. Participants performed five trials of stop-jump and sidestep tasks. A functional short-term agility protocol was performed, and immediately following participants repeated the unanticipated running tasks. Lower extremity kinematic and kinetic values were obtained pre and post fatigue. Repeated measures analyses of variance were conducted for each dependent variable with an alpha level set at 0.05. Knee position post-fatigue had increased knee internal rotation (11.4 ± 7.5° vs. 7.9 ± 6.5° p = 0.011) than pre-fatigue, and a decreased knee flexion angle (−36.6 ± 6.2° vs.−40.0 ± 6.3°, p = 0.003), as well as hip position post-fatigue had decreased hip flexion angle (35.5 ± 8.7° vs. 43.2 ± 9.5°, p = 0.002). A quick functional fatigue protocol altered lower extremity mechanics of Division I collegiate soccer athletes during landing tasks. Proper mechanics should be emphasized from the beginning of practice/game to aid in potentially minimizing the effects of fatigue in lower extremity mechanics. PMID:22424559
Results of computer assisted mini-incision subvastus approach for total knee arthroplasty.
Turajane, Thana; Larbpaiboonpong, Viroj; Kongtharvonskul, Jatupon; Maungsiri, Samart
2009-12-01
Mini-incision subvastus approach is soft tissue preservation of the knee. Advantages of the mini-incision subvastus approach included reduced blood loss, reduced pain, self rehabilitation and faster recovery. However, the improved visualization, component alignment, and more blood preservation have been debatable to achieve the better outcome and preventing early failure of the Total Knee Arthroplasty (TKA). The computer navigation has been introduced to improve alignment and blood loss. The purpose of this study was to evaluate the short term outcomes of the combination of computer assisted mini-incision subvastus approach for Total Knee Arthroplasty (CMS-TKA). A prospective case series of the initial 80 patients who underwent computer assisted mini-incision subvastus approach for CMS-TKA from January 2007 to October 2008 was carried out. The patients' conditions were classified into 2 groups, the simple OA knee (varus deformity was less than 15 degree, BMI was less than 20%, no associated deformities) and the complex deformity (varus deformity was more than 15 degrees, BMI more was than 20%, associated with flexion contractor). There were 59 patients in group 1 and 21 patients in group 2. Of the 80 knees, 38 were on the left and 42 on the right. The results of CMS-TKA [the mean (range)] in group 1: group 2 were respectively shown as the incision length [10.88 (8-13): 11.92 (10-14], the operation time [118 (111.88-125.12): 131 (119.29-143.71) minutes, lateral releases (0 in both groups), postoperative range of motion in flexion [94.5 (90-100): 95.25 (90-105) degree] and extension [1.75 (0-5): 1.5 (0-5) degree] Blood loss in 24 hours [489.09 (414.7-563.48): 520 (503.46-636.54) ml] and blood transfusion [1 (0-1) unit? in both groups], Tibiofemoral angle preoperative [Varus = 4 (varus 0-10): Varus = 17.14 (varus 15.7-18.5) degree, Tibiofemoral angle postoperative [Valgus = 1.38 (Valgus 0-4): Valgus = 2.85 (valgus 2.1-3.5) degree], Tibiofemoral angle outlier (85% both groups), and Knee society score preoperative and postoperative [64.6 (59.8-69.4) and 93.7 (90.8-96.65)]: 69 (63.6-74.39) 92.36 (88.22-96.5)]. The complications found in both groups were similar. No deep vein thrombosis, no fracture at both femur and tibia, no vascular injury, and no pin tract pain or infection was found in both groups. The computer assisted CMS-TKA) is one of the appropriate procedures for all varus deformity, no limitation with the associated bone loss, flexion contractor, BMI, except the fixed valgus deformity. To ensure the clinical outcomes, multiple key steps were considered as the appropriate techniques for this approach which included the accurate registration, precision bone cut and ligament balances, and the good cement techniques.
Mechanical Characteristics of Reflex Durign Upright Posture in Paralyzed Subjects
NASA Astrophysics Data System (ADS)
Kim, Yongchul; Youm, Youngil; Lee, Bumsuk; Kim, Youngho; Choi, Hyeonki
The characteristics of flexor reflexes have been investigated in the previous studies with human subjects who were seated or supine position. However, researchers did not describe how the spinal circuits are used in different hip angles for paralyzed subjects, such as the standing position with walker or cane. In upright posture the compatibility between a flexor reflex of leg and body balance is a special problem for lower limb injured subjects. Therefore, the purpose of this study was to investigate the effects of hip angle change on the flexor reflex evoked in standing paralyzed subjects supported by walker. In this study, six spinal cord injured and four stroke subjects were recruited through the inpatient physical therapy clinics of Korea national rehabilitation hospital. A single axis electronic goniometer was mounted on the lateral side of the hip joint of the impaired limb to record movements in the sagittal plane at this joint. The electronic goniometer was connected to a data acquisition system, through amplifiers to a computer. Since subject' posture influenced characteristics of the flexion reflex response, the subjects were supported in an upright posture by the help of parallelogram walder. Two series of tests were performed on each leg. The first series of the tests investigated the influence of hip angle during stationary standing posture on flexion reflex response. The hip angle was adjusted by the foot plate. The second examined the effect of the voluntary action of subject on swing motion during the gait. The electrically induced flexion reflex simultaneously produced the flexion of the hip, knee and dorsiflexion of the ankle enabling the swing phase of walking. Form the experimental results we observed that the reflex response of hip joint was largerwith the hip in the extended position than in the flexed position during standing posture. Under voluntary movement on flexion reflex during gaint, the peak hip angle induced by stimulation was increased in spinal cord injury and stroke patients by subject' voluntary movement.
Shalhoub, Sami; Moschetti, Wayne E; Dabuzhsky, Leonid; Jevsevar, David S; Keggi, John M; Plaskos, Christopher
2018-05-14
The traditional goal of the gap-balancing method in total knee arthroplasty is to create equal and symmetric knee laxity throughout the arc of flexion. The purpose of this study was to (1) quantify the laxity in the native and the replaced knee throughout the range of flexion in gap-balancing total knee arthroplasty (TKA) and (2) quantify the precision in achieving a targeted gap profile throughout flexion using a robotic-assisted technique with active ligament tensioning. Robotic-assisted, gap-balancing TKA was performed in 14 cadaver specimens. The proximal tibia was resected, and the native tibiofemoral gaps were measured using a robotic tensioner that dynamically tensioned the soft-tissue envelope throughout the arc of flexion. The femoral implant was then aligned to balance the gaps at 0° and 90° of flexion. The postoperative gaps were then measured during final trialing with the robotic tensioner and compared with the planned gaps. The native gaps increased by 3.4 ± 1.7 mm medially and 3.7 ± 2.1 mm laterally from full extension to 20° of flexion (P < .001) and then remained consistent through the remaining arc of flexion. Gap balancing after TKA produced equal gaps at 0° and 90° of flexion, but the gap laxity in midflexion was 2-4 mm greater than at 0° and 90° (P < .001). The root mean square error between the planned gaps and actual measured postoperative gaps was 1.6 mm medially and 1.7 mm laterally throughout the range of motion. Aiming for equal gaps at 0° and 90° of flexion produced equal gaps in extension and flexion with larger gaps in midflexion. Consistent soft-tissue balance to a planned gap profile could be achieved by using controlled ligament tensioning in robotic-assisted TKA. Copyright © 2018 Elsevier Inc. All rights reserved.
Single-leg hop testing following fatiguing exercise: reliability and biomechanical analysis.
Augustsson, J; Thomeé, R; Lindén, C; Folkesson, M; Tranberg, R; Karlsson, J
2006-04-01
A fatiguing exercise protocol was combined with single-leg hop testing to improve the possibilities of evaluating the effects of training or rehabilitation interventions. In the first test-retest experiment, 11 healthy male subjects performed two trials of single-leg hops under three different test conditions: non-fatigued and following fatiguing exercise, which consisted of unilateral weight machine knee extensions at 80% and 50%, respectively, of 1 repetition maximum (1 RM) strength. Intraclass correlation coefficients ranged from 0.75 to 0.98 for different hop test conditions, indicating that all tests were reliable. For the second experiment, eight healthy male subjects performed the fatiguing exercise protocol to investigate how fatigue influences lower-extremity joint kinematics and kinetics during single-leg hops. Hip, knee and ankle joint angles, moments and powers, as well as ground-reaction forces were recorded with a six-camera, motion-capture system and a force platform. Recovery of hop performance following the fatiguing exercise was also measured. During the take-off for the single-leg hops, hip and knee flexion angles, generated powers for the knee and ankle joints, and ground-reaction forces decreased for the fatigued hop conditions compared with the non-fatigued condition (P<0.05). Compared with landing during the non-fatigued condition, hip moments and ground-reaction forces were lower for the fatigued hop conditions (P<0.05). The negative joint power was two to three times greater for the knee than for the hip and five to 10 times greater for the knee than for the ankle during landing for all test conditions (P<0.05). Most measured variables had recovered three minutes post-exercise. It is concluded that the fatiguing exercise protocol combined with single-leg hop testing was a reliable method for investigating functional performance under fatigued test conditions. Further, subjects utilized an adapted hop strategy, which employed less hip and knee flexion and generated powers for the knee and ankle joints during take-off, and less hip joint moments during landing under fatigued conditions. The large negative power values observed at the knee joint during the landing phase of the single-leg hop, during which the quadriceps muscle activates eccentrically, indicate that not only hop distance but also the ability to perform successful landings should be investigated when assessing dynamic knee function.
Effects of Sex and Fatigue on Biomechanical Measures During the Drop-Jump Task in Children
Briem, Kristín; Jónsdóttir, Kolbrún Vala; Árnason, Árni; Sveinsson, Þórarinn
2017-01-01
Background: Female athletes have a higher rate of anterior cruciate ligament (ACL) injury than males from adolescence and into maturity, which is suggested to result from sex-specific changes in dynamic movement patterns with maturation. Few studies have studied movement strategies and response to fatigue in children. Purpose: To evaluate the effect of fatigue on biomechanical variables associated with increased risk for ACL injury during a drop-jump (DJ) performance in children. Study Design: Controlled laboratory study. Methods: A total of 116 children (mean age, 10.4 years) were recruited from local sports clubs and performed 5 repetitions of a DJ task before and after a fatigue protocol. Kinematic and kinetic data from initial contact (IC) to the first peak vertical ground reaction force (vGRF) were analyzed for both limbs, including limb and fatigue as within-subject factors for analyses between boys and girls. Pearson correlation coefficients were calculated to identify associations between variables of interest. Results: Girls demonstrated greater peak vGRF values than boys (by 8.1%; P < .05), there were greater peak vGRF values for the right limb than the left (by 6.2%; P < .001), and fatigue led to slightly greater values (P < .05). Although weak, the correlation between peak vGRF values and knee flexion excursion was stronger for girls (r = –0.20) than boys (r = –0.08) (P < .006). Fatigue resulted in greater knee flexion angles at IC and less excursion during landing, more so for girls (by 6.1° vs 1.4°; interaction, P < .001), although the knee flexion moment was generally lowered by fatigue (P < .001). Limb asymmetry in knee flexion moments was more pronounced for boys than for girls (interaction, P < .05), contrary to that seen in frontal plane knee moments, where asymmetry was much greater in girls than boys (interaction, P < .001). Conclusion: Even as young athletes, girls and boys seem to adopt dissimilar movement strategies and are differently affected by fatigue. Clinical Relevance: Injury prevention programs should be considered at an earlier age in an effort to lower the risk of ACL injury in athletes. PMID:28203593
Changes in Contact Area in Meniscus Horizontal Cleavage Tears Subjected to Repair and Resection.
Beamer, Brandon S; Walley, Kempland C; Okajima, Stephen; Manoukian, Ohan S; Perez-Viloria, Miguel; DeAngelis, Joseph P; Ramappa, Arun J; Nazarian, Ara
2017-03-01
To assess the changes in tibiofemoral contact pressure and contact area in human knees with a horizontal cleavage tear before and after treatment. Ten human cadaveric knees were tested. Pressure sensors were placed under the medial meniscus and the knees were loaded at twice the body weight for 20 cycles at 0°, 10°, and 20° of flexion. Contact area and pressure were recorded for the intact meniscus, the meniscus with a horizontal cleavage tear, after meniscal repair, after partial meniscectomy (single leaflet), and after subtotal meniscectomy (double leaflet). The presence of a horizontal cleavage tear significantly increased average peak contact pressure and reduced effective average tibiofemoral contact area at all flexion angles tested compared with the intact state (P < .03). There was approximately a 70% increase in contact pressure after creation of the horizontal cleavage tear. Repairing the horizontal cleavage tear restored peak contact pressures and areas to within 15% of baseline, statistically similar to the intact state at all angles tested (P < .05). Partial meniscectomy and subtotal meniscectomy significantly increased average peak contact pressure and reduced average contact area at all degrees of flexion compared with the intact state (P < .05). The presence of a horizontal cleavage tear in the medial meniscus causes a significant reduction in contact area and a significant elevation in contact pressure. These changes may accelerate joint degeneration. A suture-based repair of these horizontal cleavage tears returns the contact area and contact pressure to nearly normal, whereas both partial and subtotal meniscectomy lead to significant reductions in contact area and significant elevations in contact pressure within the knee. Repairing horizontal cleavage tears may lead to improved clinical outcomes by preserving meniscal tissue and the meniscal function. Understanding contact area and peak contact pressure resulting from differing strategies for treating horizontal cleavage tears will allow the surgeon to evaluate the best strategy for treating his or her patients who present with this meniscal pathology. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Repositioning the knee joint in human body FE models using a graphics-based technique.
Jani, Dhaval; Chawla, Anoop; Mukherjee, Sudipto; Goyal, Rahul; Vusirikala, Nataraju; Jayaraman, Suresh
2012-01-01
Human body finite element models (FE-HBMs) are available in standard occupant or pedestrian postures. There is a need to have FE-HBMs in the same posture as a crash victim or to be configured in varying postures. Developing FE models for all possible positions is not practically viable. The current work aims at obtaining a posture-specific human lower extremity model by reconfiguring an existing one. A graphics-based technique was developed to reposition the lower extremity of an FE-HBM by specifying the flexion-extension angle. Elements of the model were segregated into rigid (bones) and deformable components (soft tissues). The bones were rotated about the flexion-extension axis followed by rotation about the longitudinal axis to capture the twisting of the tibia. The desired knee joint movement was thus achieved. Geometric heuristics were then used to reposition the skin. A mapping defined over the space between bones and the skin was used to regenerate the soft tissues. Mesh smoothing was then done to augment mesh quality. The developed method permits control over the kinematics of the joint and maintains the initial mesh quality of the model. For some critical areas (in the joint vicinity) where element distortion is large, mesh smoothing is done to improve mesh quality. A method to reposition the knee joint of a human body FE model was developed. Repositions of a model from 9 degrees of flexion to 90 degrees of flexion in just a few seconds without subjective interventions was demonstrated. Because the mesh quality of the repositioned model was maintained to a predefined level (typically to the level of a well-made model in the initial configuration), the model was suitable for subsequent simulations.
Vanlommel, L; Luyckx, T; Vercruysse, G; Bellemans, J; Vandenneucker, H
2017-11-01
Flexion in a stiff total knee arthroplasty (TKA) can be improved by manipulation under anaesthesia (MUA). Although this intervention usually results in an improvement in range of motion, the expected result is not always achieved. The purpose of this study is to determine which factors affect range of motion after manipulation in patients with a stiff total knee. After exclusion (n = 22), the data of 158 patients (138 knees) with a stiff knee after TKA who received a manipulation under anaesthesia between 2004 and 2014 were retrospectively analysed. Pre-, peri- and post-operative variables were identified and examined for their influence on flexion after the manipulation using Kruskal-Wallis and Mann-Whitney U tests and Spearman correlations. After MUA, a mean improvement in flexion of 30.3° was observed at the final follow-up. Preoperative TKA flexion, design of TKA and interval between TKA procedure and MUA were positive associated with an increase in flexion after MUA. MUA performed 12 weeks or more after TKA procedure deteriorated the outcome. Three factors, pre-TKA flexion type of prosthesis and interval between TKA procedure and manipulation under anaesthesia, were found to have impact on flexion after TKA and MUA were identified. Results are expected to be inferior in patients with low flexion before TKA procedure or with a long interval (>12 weeks) between the TKA procedure and the manipulation under anaesthesia. IV.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Niitsu, Mamoru; Ikeda, Kotaroh; Fukubayashi, Tohru
Our goal was to assess the effect of joint position of semiflexed and extended knees in MR delineation of the anterior cruciate ligament (ACL). With a mobile knee brace and a flexible surface coil, the knee joint was either fully extended or bent to a semiflexed position (average 45{degrees} of flexion) within the magnet bore. Sets of oblique sagittal MR images were obtained for both extended and flexed knee positions. Thirty-two knees with intact ACLs and 43 knees with arthroscopically proven ACL tears were evaluated. Two observers compared paired MR images of both extended and flexed positions and rated themmore » by a relative three point scale. Anatomic correlation in MR images was obtained by a cadaveric knee with incremental flexion. The MR images of flexed knees were more useful than of extended knees in 53% of the case reviews of femoral attachments and 36% of reviews of midportions of normal ACLs. Compared with knee extensions, the MR images for knee flexion provided better clarity in 48% of reviews of disrupted sites and 52% of residual bundles of torn ACLs. Normal ACL appeared taut in the knee extension and lax in semiflexion. Compared with MR images of knees in extension, MR images of knees in flexion more clearly delineate the femoral side of the ligament with wider space under the intercondylar roof and with decreased volume-averaging artifacts, providing superior visualization of normal and torn ACLs. 13 refs., 7 figs., 1 tab.« less
Relph, Nicola; Herrington, Lee
2016-12-01
Following an ACL injury, reconstruction (ACL-R) and rehabilitation, athletes may return to play with a proprioceptive deficit. However, literature is lacking to support this hypothesis in elite athletic groups who have returned to international levels of performance. It is possible the potentially heightened proprioceptive ability evidenced in athletes may negate a deficit following injury. The purpose of this study was to consider the effects of ACL injury, reconstruction and rehabilitation on knee joint position sense (JPS) on a group of elite athletes who had returned to international performance. Using a cross-sectional design ten elite athletes with ACL-R and ten controls were evaluated. JPS was tested into knee extension and flexion using absolute error scores. Average data with 95% confidence intervals between the reconstructed, contralateral and uninjured control knees were analyzed using t-tests and effect sizes. The reconstructed knee of the injured group demonstrated significantly greater angle of error scores when compared to the contralateral and uninjured control into knee flexion (p=0.0001, r=0.98) and knee extension (p=0.0001, r=0.91). There were no significant differences between the contralateral uninjured knee of the injured group and the uninjured control group. Elite athletes who have had an ACL injury, reconstruction, rehabilitation and returned to international play demonstrate lower JPS ability compared to control groups. It is unclear if this deficiency affects long-term performance or secondary injury and re-injury problems. In the future physical therapists should monitor athletes longitudinally when they return to play. Copyright © 2016 Elsevier B.V. All rights reserved.
Comparison of MRI-based estimates of articular cartilage contact area in the tibiofemoral joint.
Henderson, Christopher E; Higginson, Jill S; Barrance, Peter J
2011-01-01
Knee osteoarthritis (OA) detrimentally impacts the lives of millions of older Americans through pain and decreased functional ability. Unfortunately, the pathomechanics and associated deviations from joint homeostasis that OA patients experience are not well understood. Alterations in mechanical stress in the knee joint may play an essential role in OA; however, existing literature in this area is limited. The purpose of this study was to evaluate the ability of an existing magnetic resonance imaging (MRI)-based modeling method to estimate articular cartilage contact area in vivo. Imaging data of both knees were collected on a single subject with no history of knee pathology at three knee flexion angles. Intra-observer reliability and sensitivity studies were also performed to determine the role of operator-influenced elements of the data processing on the results. The method's articular cartilage contact area estimates were compared with existing contact area estimates in the literature. The method demonstrated an intra-observer reliability of 0.95 when assessed using Pearson's correlation coefficient and was found to be most sensitive to changes in the cartilage tracings on the peripheries of the compartment. The articular cartilage contact area estimates at full extension were similar to those reported in the literature. The relationships between tibiofemoral articular cartilage contact area and knee flexion were also qualitatively and quantitatively similar to those previously reported. The MRI-based knee modeling method was found to have high intra-observer reliability, sensitivity to peripheral articular cartilage tracings, and agreeability with previous investigations when using data from a single healthy adult. Future studies will implement this modeling method to investigate the role that mechanical stress may play in progression of knee OA through estimation of articular cartilage contact area.
Kobayashi, Toshiki; Singer, Madeline L.; Orendurff, Michael S.; Gao, Fan; Daly, Wayne K.; Foreman, K. Bo
2015-01-01
Background The adjustment of plantarflexion resistive moment of an articulated ankle-foot orthosis is considered important in patients post stroke, but the evidence is still limited. Therefore, the aim of this study was to investigate the effect of changing the plantarflexion resistive moment of an articulated ankle-foot orthosis on ankle and knee joint angles and moments in patients post stroke. Methods Gait analysis was performed on 10 subjects post stroke under four different plantarflexion resistive moment conditions using a newly designed articulated ankle-foot orthosis. Data were recorded using a Bertec split-belt instrumented treadmill in a 3-dimensional motion analysis laboratory. Findings The ankle and knee sagittal joint angles and moments were significantly affected by the amount of plantarflexion resistive moment of the ankle-foot orthosis. Increasing the plantarflexion resistive moment of the ankle-foot orthosis induced significant decreases both in the peak ankle plantarflexion angle (P<0.01) and the peak knee extension angle (P<0.05). Also, the increase induced significant increases in the internal dorsiflexion moment of the ankle joint (P<0.01) and significantly decreased the internal flexion moment of the knee joint (P<0.01). Interpretation These results suggest an important link between the kinematic/kinetic parameters of the lower-limb joints and the plantarflexion resistive moment of an articulated ankle-foot orthosis. A future study should be performed to clarify their relationship further so that the practitioners may be able to use these parameters as objective data to determine an optimal plantarflexion resistive moment of an articulated ankle-foot orthosis for improved orthotic care in individual patients. PMID:26149007
Kobayashi, Toshiki; Singer, Madeline L; Orendurff, Michael S; Gao, Fan; Daly, Wayne K; Foreman, K Bo
2015-10-01
The adjustment of plantarflexion resistive moment of an articulated ankle-foot orthosis is considered important in patients post stroke, but the evidence is still limited. Therefore, the aim of this study was to investigate the effect of changing the plantarflexion resistive moment of an articulated ankle-foot orthosis on ankle and knee joint angles and moments in patients post stroke. Gait analysis was performed on 10 subjects post stroke under four different plantarflexion resistive moment conditions using a newly designed articulated ankle-foot orthosis. Data were recorded using a Bertec split-belt instrumented treadmill in a 3-dimensional motion analysis laboratory. The ankle and knee sagittal joint angles and moments were significantly affected by the amount of plantarflexion resistive moment of the ankle-foot orthosis. Increasing the plantarflexion resistive moment of the ankle-foot orthosis induced significant decreases both in the peak ankle plantarflexion angle (P<0.01) and the peak knee extension angle (P<0.05). Also, the increase induced significant increases in the internal dorsiflexion moment of the ankle joint (P<0.01) and significantly decreased the internal flexion moment of the knee joint (P<0.01). These results suggest an important link between the kinematic/kinetic parameters of the lower-limb joints and the plantarflexion resistive moment of an articulated ankle-foot orthosis. A future study should be performed to clarify their relationship further so that the practitioners may be able to use these parameters as objective data to determine an optimal plantarflexion resistive moment of an articulated ankle-foot orthosis for improved orthotic care in individual patients. Copyright © 2015 Elsevier Ltd. All rights reserved.
IMU-Based Joint Angle Measurement for Gait Analysis
Seel, Thomas; Raisch, Jorg; Schauer, Thomas
2014-01-01
This contribution is concerned with joint angle calculation based on inertial measurement data in the context of human motion analysis. Unlike most robotic devices, the human body lacks even surfaces and right angles. Therefore, we focus on methods that avoid assuming certain orientations in which the sensors are mounted with respect to the body segments. After a review of available methods that may cope with this challenge, we present a set of new methods for: (1) joint axis and position identification; and (2) flexion/extension joint angle measurement. In particular, we propose methods that use only gyroscopes and accelerometers and, therefore, do not rely on a homogeneous magnetic field. We provide results from gait trials of a transfemoral amputee in which we compare the inertial measurement unit (IMU)-based methods to an optical 3D motion capture system. Unlike most authors, we place the optical markers on anatomical landmarks instead of attaching them to the IMUs. Root mean square errors of the knee flexion/extension angles are found to be less than 1° on the prosthesis and about 3° on the human leg. For the plantar/dorsiflexion of the ankle, both deviations are about 1°. PMID:24743160
NASA Astrophysics Data System (ADS)
Gomes Leal-Junior, Arnaldo; Frizera-Neto, Anselmo; José Pontes, Maria; Rodrigues Botelho, Thomaz
2017-12-01
Polymer optical fiber (POF) curvature sensors present some advantages over conventional techniques for angle measurements, such as their light weight, compactness and immunity to electromagnetic fields. However, high hysteresis can occur in POF curvature sensors due to the polymer viscoelastic response. In order to overcome this limitation, this paper shows how the hysteresis sensor can be compensated by a calibration equation relating the measured output signal to the sensor’s angular velocity. The proposed method is validated using an exoskeleton with an active joint on the knee for flexion and extension rehabilitation exercises. The results show a decrease in sensor hysteresis and a decrease by more than two times in the error between the POF sensor and the potentiometer, which is employed for the angle measurement of the exoskeleton knee joint.
Soft Smart Garments for Lower Limb Joint Position Analysis.
Totaro, Massimo; Poliero, Tommaso; Mondini, Alessio; Lucarotti, Chiara; Cairoli, Giovanni; Ortiz, Jesùs; Beccai, Lucia
2017-10-12
Revealing human movement requires lightweight, flexible systems capable of detecting mechanical parameters (like strain and pressure) while being worn comfortably by the user, and not interfering with his/her activity. In this work we address such multifaceted challenge with the development of smart garments for lower limb motion detection, like a textile kneepad and anklet in which soft sensors and readout electronics are embedded for retrieving movement of the specific joint. Stretchable capacitive sensors with a three-electrode configuration are built combining conductive textiles and elastomeric layers, and distributed around knee and ankle. Results show an excellent behavior in the ~30% strain range, hence the correlation between sensors' responses and the optically tracked Euler angles is allowed for basic lower limb movements. Bending during knee flexion/extension is detected, and it is discriminated from any external contact by implementing in real time a low computational algorithm. The smart anklet is designed to address joint motion detection in and off the sagittal plane. Ankle dorsi/plantar flexion, adduction/abduction, and rotation are retrieved. Both knee and ankle smart garments show a high accuracy in movement detection, with a RMSE less than 4° in the worst case.
Soft Smart Garments for Lower Limb Joint Position Analysis
Totaro, Massimo; Poliero, Tommaso; Mondini, Alessio; Lucarotti, Chiara; Cairoli, Giovanni; Ortiz, Jesùs; Beccai, Lucia
2017-01-01
Revealing human movement requires lightweight, flexible systems capable of detecting mechanical parameters (like strain and pressure) while being worn comfortably by the user, and not interfering with his/her activity. In this work we address such multifaceted challenge with the development of smart garments for lower limb motion detection, like a textile kneepad and anklet in which soft sensors and readout electronics are embedded for retrieving movement of the specific joint. Stretchable capacitive sensors with a three-electrode configuration are built combining conductive textiles and elastomeric layers, and distributed around knee and ankle. Results show an excellent behavior in the ~30% strain range, hence the correlation between sensors’ responses and the optically tracked Euler angles is allowed for basic lower limb movements. Bending during knee flexion/extension is detected, and it is discriminated from any external contact by implementing in real time a low computational algorithm. The smart anklet is designed to address joint motion detection in and off the sagittal plane. Ankle dorsi/plantar flexion, adduction/abduction, and rotation are retrieved. Both knee and ankle smart garments show a high accuracy in movement detection, with a RMSE less than 4° in the worst case. PMID:29023365
Darrah, Shaun D; Dicianno, Brad E; Berthold, Justin; McCoy, Andrew; Haas, Matthew; Cooper, Rory A
2016-01-01
To determine whether sledge hockey players with physical disability have higher average seated pressures compared to non-disabled controls. Fifteen age-matched controls without physical disability and 15 experimental participants with physical disability were studied using a pressure mapping device to determine risk for skin pressure ulceration and the impact of cushioning and knee angle positioning on seated pressure distributions. Regardless of participant group, cushioning, or knee angle, average seated pressures exceeded clinically acceptable seated pressures. Controls had significantly higher average seated pressures than the disability group when knees were flexed, both with the cushion (p = 0.013) and without (p = 0.015). Knee extension showed significantly lower average pressures in controls, both with the cushion (p < 0.001) and without (p < 0.001). Placement of the cushion resulted in significantly lower average pressure in controls when knees were extended (p = 0.024) but not when flexed (p = 0.248). Placement of the cushion resulted in no difference in pressure (p = 0.443) in the disability group. Pressures recorded indicate high risk for skin ulceration. Cushioning was effective only in the control group with knees extended. That knee extension significantly lowered average seated pressures is important, as many sledge hockey players utilize positioning with larger knee flexion angles. Implications for Rehabilitation Ice sledge hockey is a fast growing adaptive sport. Adaptive sports have been associated with several positive improvements in overall health and quality of life, though may be putting players at risk for skin ulceration. Measured static seated pressure in sledges greatly exceeds current clinically accepted clinical guidelines. With modern improvements in wheelchair pressure relief/cushioning there are potential methods for improvement of elevated seated pressure in ice hockey sledges.
Effect of a pelvic wedge and belt on the medial and lateral hamstring muscles during knee flexion.
Yoo, Won-Gyu
2017-01-01
[Purpose] This study developed a pelvic wedge and belt and investigated their effects on the selective activation of medial and lateral hamstring muscles during knee flexion. [Subjects and Methods] Nine adults were enrolled. The participants performed exercises without and with the pelvic wedge and belt, and the electromyographic activities of the medial and lateral hamstring muscles were recorded. [Results] The activity of the medial hamstring was increased significantly when using the pelvic wedge and belt, while the activity of the lateral hamstring did not differ significantly. [Conclusion] The pelvic wedge and belt provide a self-locked position during knee flexion in the prone position. Prone knee flexion in this position is an effective self-exercise for balanced strengthening of the medial hamstring.
Effect of a pelvic wedge and belt on the medial and lateral hamstring muscles during knee flexion
Yoo, Won-gyu
2017-01-01
[Purpose] This study developed a pelvic wedge and belt and investigated their effects on the selective activation of medial and lateral hamstring muscles during knee flexion. [Subjects and Methods] Nine adults were enrolled. The participants performed exercises without and with the pelvic wedge and belt, and the electromyographic activities of the medial and lateral hamstring muscles were recorded. [Results] The activity of the medial hamstring was increased significantly when using the pelvic wedge and belt, while the activity of the lateral hamstring did not differ significantly. [Conclusion] The pelvic wedge and belt provide a self-locked position during knee flexion in the prone position. Prone knee flexion in this position is an effective self-exercise for balanced strengthening of the medial hamstring. PMID:28210048
Is midsole thickness a key parameter for the running pattern?
Chambon, Nicolas; Delattre, Nicolas; Guéguen, Nils; Berton, Eric; Rao, Guillaume
2014-01-01
Many studies have highlighted differences in foot strike pattern comparing habitually shod runners who ran barefoot and with running shoes. Barefoot running results in a flatter foot landing and in a decreased vertical ground reaction force compared to shod running. The aim of this study was to investigate one possible parameter influencing running pattern: the midsole thickness. Fifteen participants ran overground at 3.3 ms(-1) barefoot and with five shoes of different midsole thickness (0 mm, 2 mm, 4 mm, 8 mm, 16 mm) with no difference of height between rearfoot and forefoot. Impact magnitude was evaluated using transient peak of vertical ground reaction force, loading rate, tibial acceleration peak and rate. Hip, knee and ankle flexion angles were computed at touch-down and during stance phase (range of motion and maximum values). External net joint moments and stiffness for hip, knee and ankle joints were also observed as well as global leg stiffness. No significant effect of midsole thickness was observed on ground reaction force and tibial acceleration. However, the contact time increased with midsole thickness. Barefoot running compared to shod running induced ankle in plantar flexion at touch-down, higher ankle dorsiflexion and lower knee flexion during stance phase. These adjustments are suspected to explain the absence of difference on ground reaction force and tibial acceleration. This study showed that the presence of very thin footwear upper and sole was sufficient to significantly influence the running pattern. Copyright © 2014 Elsevier B.V. All rights reserved.
Lee, Seung-Yup; Bae, Ji-Hoon; Suh, Dong-Won; Kim, Han-Ju; Lim, Hong-Chul
2017-02-01
This mediolateral excursion of the bearing during knee motion is supposed to be caused by external rotation of the tibia during knee extension. However, to our knowledge, there is no published clinical evidence supporting these hypotheses. The current study aimed to evaluate the mediolateral excursion of the bearing during flexion-extension motion of the knee after medial unicompartmental knee arthroplasty (UKA). In 52 knees, varus/valgus (F-VarVal) or rotational position (F-Rot) of the femoral component and relative location of the bearing were measured with the standing anteroposterior and modified axial view, respectively. We adopted the modified axial radiographs that are simple to assess the bearing position in the flexed knee. The modified axial view showed excellent inter- and intraobserver agreements. F-Rot in the modified axial view and CT showed a high agreement in terms of validity (r = 0.98; p < 0.0001). On average, the bearing showed more medial position in extension than flexion of the knee. No correlation was found between the femoral component positions (F-VarVal and F-Rot) and mediolateral bearing excursion ( p = 0.68 and 0.80, respectively). In conclusion, coronal location of bearing according to flexion-extension of the knee is not influenced by the coronal and axial alignment of the femoral component. With simple radiographic method, more medial position of the bearing according to flexion-extension of the knee. Our method could be used to assess axial rotation of the femoral component and spin-out phenomenon of the bearing following the medial UKA. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Arazpour, Mokhtar; Moradi, Alireza; Samadian, Mohammad; Bahramizadeh, Mahmood; Joghtaei, Mahmoud; Ahmadi Bani, Monireh; Hutchins, Stephen W; Mardani, Mohammad A
2016-06-01
Traditionally, the anatomical knee joint is locked in extension when walking with a conventional knee-ankle-foot orthosis. A powered knee-ankle-foot orthosis was developed to provide restriction of knee flexion during stance phase and active flexion and extension of the knee during swing phase of gait. The purpose of this study was to determine differences of the powered knee-ankle-foot orthosis compared to a locked knee-ankle-foot orthosis in kinematic data and temporospatial parameters during ambulation. Quasi-experimental design. Subjects with poliomyelitis (n = 7) volunteered for this study and undertook gait analysis with both the powered and the conventional knee-ankle-foot orthoses. Three trials per orthosis were collected while each subject walked along a 6-m walkway using a calibrated six-camera three-dimensional video-based motion analysis system. Walking with the powered knee-ankle-foot orthosis resulted in a significant reduction in both walking speed and step length (both 18%), but a significant increase in stance phase percentage compared to walking with the conventional knee-ankle-foot orthosis. Cadence was not significantly different between the two test conditions (p = 0.751). There was significantly higher knee flexion during swing phase and increased hip hiking when using the powered orthosis. The new powered orthosis permitted improved knee joint kinematic for knee-ankle-foot orthosis users while providing knee support in stance and active knee motion in swing in the gait cycle. Therefore, the new powered orthosis provided more natural knee flexion during swing for orthosis users compared to the locked knee-ankle-foot orthosis. This orthosis has the potential to improve knee joint kinematics and gait pattern in poliomyelitis subjects during walking activities. © The International Society for Prosthetics and Orthotics 2015.
Movement Strategies among Groups of Chronic Ankle Instability, Coper, and Control.
Son, S Jun; Kim, Hyunsoo; Seeley, Matthew K; Hopkins, J Ty
2017-08-01
Comprehensive evaluation of movement strategies during functional movement is a difficult undertaking. Because of this challenge, studied movements have been oversimplified. Furthermore, evaluating movement strategies at only a discrete time point(s) provide limited insight into how movement strategies may change or adapt in chronic ankle instability (CAI) patients. This study aimed to identify abnormal movement strategies in individuals with a history of ankle sprain injury during a sports maneuver compared with healthy controls. Sixty-six participants, consisting of 22 CAI patients, 22 ankle sprain copers, and 22 healthy controls, participated in this study. Functional profiles of lower extremity kinematics, kinetics, and EMG activation from initial contact (0% of stance) to toe-off (100% of stance) were collected and analyzed during a jump landing/cutting task using a functional data analysis approach. Compared with copers, CAI patients displayed landing positions of less plantarflexion, less inversion, more knee flexion, more hip flexion, and less hip abduction during the first 25% of stance. However, restricted dorsiflexion angle was observed in both CAI patients and copers relative to controls during the midlanding to mid-side-cutting phase when the ankle and knee reached its peak range of motion (e.g., dorsiflexion and knee flexion). Reduced EMG activation of tibialis anterior, peroneus longus, medial gastrocnemius, and gluteus medius may be due to altered kinematics that reduce muscular demands on the involved muscles. CAI patients displayed altered movement strategies, perhaps in an attempt to avoid perceived positions of risk. Although sagittal joint positions seemed to increase the external torque on the knee and hip extensors, frontal joint positions appeared to reduce the muscular demands on evertor and hip abductor muscles.
Stephensen, D; Drechsler, W; Winter, M; Scott, O
2009-03-01
Quality of life for children with haemophilia has improved since the introduction of prophylaxis. The frequency of joint haemorrhages has reduced, but the consequences of reduced bleeding on the biomechanical parameters of walking are not well understood. This study explored the differences in sagittal plane biomechanics of walking between a control group (Group 1) of normal age-matched children and children with haemophilia (Group 2) with a target ankle joint. A motion capture system and two force platforms were used to collect sagittal plane kinematic, kinetic and temporal-spatial data during walking of 14 age-matched normal children and 14 children with haemophilia aged 7-13 years. Group differences in maximum and minimum flexion/extension angles and moments of the hip, knee and ankle joints, ground reaction forces and temporal-spatial gait cycle parameters were analysed using one-way anova. Significant changes (P < 0.05) in kinematic and kinetic parameters but not temporal-spatial parameters were found in children with haemophilia; greater flexion angles and external moments of force at the knee, greater ankle plantarflexion external moments and lower hip flexion external moments. These results suggest that early biomechanical changes are present in young haemophilic children with a history of a target ankle joint and imply that lower limb joint function is more impaired than current clinical evaluations indicate. Protocols and quantitative data on the biomechanical gait pattern of children with haemophilia reported in this study provide a baseline to evaluate lower limb joint function and clinical progression.
Six degree-of-freedom knee joint kinematics in obese individuals with knee pain during gait.
Li, Jing-Sheng; Tsai, Tsung-Yuan; Felson, David T; Li, Guoan; Lewis, Cara L
2017-01-01
Knee joint pain is a common symptom in obese individuals and walking is often prescribed as part of management programs. Past studies in obese individuals have focused on standing alignment and kinematics in the sagittal and coronal planes. Investigation of 6 degree-of-freedom (6DOF) knee joint kinematics during standing and gait is important to thoroughly understand knee function in obese individuals with knee pain. This study aimed to investigate the 6DOF knee joint kinematics in standing and during gait in obese patients using a validated fluoroscopic imaging system. Ten individuals with obesity and knee pain were recruited. While standing, the knee was in 7.4±6.3°of hyperextension, 2.8±3.3° of abduction and 5.6±7.3° of external rotation. The femoral center was located 0.7±3.1mm anterior and 5.1±1.5mm medial to the tibial center. During treadmill gait, the sagittal plane motion, i.e., flexion/extension and anterior-posterior translation, showed a clear pattern. Specifically, obese individuals with knee pain maintained the knee in more flexion and more anterior tibial translation during most of the stance phase of the gait cycle and had a reduced total range of knee flexion when compared to a healthy non-obese group. In conclusion, obese individuals with knee pain used hyperextension knee posture while standing, but maintained the knee in more flexion during gait with reduced overall range of motion in the 6DOF analysis.
Six degree-of-freedom knee joint kinematics in obese individuals with knee pain during gait
Li, Jing-Sheng; Tsai, Tsung-Yuan; Felson, David T.; Li, Guoan; Lewis, Cara L.
2017-01-01
Knee joint pain is a common symptom in obese individuals and walking is often prescribed as part of management programs. Past studies in obese individuals have focused on standing alignment and kinematics in the sagittal and coronal planes. Investigation of 6 degree-of-freedom (6DOF) knee joint kinematics during standing and gait is important to thoroughly understand knee function in obese individuals with knee pain. This study aimed to investigate the 6DOF knee joint kinematics in standing and during gait in obese patients using a validated fluoroscopic imaging system. Ten individuals with obesity and knee pain were recruited. While standing, the knee was in 7.4±6.3°of hyperextension, 2.8±3.3° of abduction and 5.6±7.3° of external rotation. The femoral center was located 0.7±3.1mm anterior and 5.1±1.5mm medial to the tibial center. During treadmill gait, the sagittal plane motion, i.e., flexion/extension and anterior-posterior translation, showed a clear pattern. Specifically, obese individuals with knee pain maintained the knee in more flexion and more anterior tibial translation during most of the stance phase of the gait cycle and had a reduced total range of knee flexion when compared to a healthy non-obese group. In conclusion, obese individuals with knee pain used hyperextension knee posture while standing, but maintained the knee in more flexion during gait with reduced overall range of motion in the 6DOF analysis. PMID:28339477
Kömürcü, Erkam; Yüksel, Halil Yalçın; Ersöz, Murat; Aktekin, Cem Nuri; Hapa, Onur; Çelebi, Levent; Akbal, Ayla; Biçimoğlu, Ali
2014-12-01
The aim of this study was to evaluate the effect of knee position during wound closure (flexed vs. extended) in total knee arthroplasty on knee strength and function, as determined by knee society scores and isokinetic testing of extensor and flexor muscle groups. In a prospective, randomized, double-blind trial, 29 patients were divided in two groups: for Group 1 patients, surgical closing was performed with the knee extended, and for Group 2 patients, the knee flexed at 90°. All the patients were treated with the same anaesthesia method, surgical team, surgical technique, prosthesis type, and rehabilitation process. American Knee Society Score values and knee flexion degrees were recorded. Isokinetic muscle strength measurements of both knees in flexion and extension were taken using 60° and 180°/s angular velocity. The peak torque and total work values, isokinetic muscle strength differences, and total work difference values were calculated for surgically repaired and healthy knees. No significant difference in the mean American Knee Society Score values and knee flexion degrees was observed between the two groups. However, using isokinetic evaluation, a significant difference was found in the isokinetic muscle strength differences and total work difference of the flexor muscle between the two groups when patients were tested at 180°/s. Less loss of strength was detected in the isokinetic muscle strength differences of the flexor muscle in Group 2 (-4.2%) than in Group 1 (-23.1%). For patients undergoing total knee arthroplasty, post-operative flexor muscle strength is improved if the knee is flexed during wound closure. II.
Landing Biomechanics in Participants With Different Static Lower Extremity Alignment Profiles
Nguyen, Anh-Dung; Shultz, Sandra J.; Schmitz, Randy J.
2015-01-01
Context: Whereas static lower extremity alignment (LEA) has been identified as a risk factor for anterior cruciate ligament injury, little is known about its influence on joint motion and moments commonly associated with anterior cruciate ligament injury. Objective: To cluster participants according to combinations of LEA variables and compare these clusters in hip- and knee-joint kinematics and kinetics during the landing phase of a drop-jump task. Design: Descriptive laboratory study. Setting: Research laboratory. Patients or Other Participants: A total of 141 participants (50 men: age = 22.2 ± 2.8 years, height = 177.9 ± 9.3 cm, weight = 80.9 ± 13.3 kg; 91 women: age = 21.2 ± 2.6 years, height = 163.9 ± 6.6 cm, weight = 61.1 ± 8.7 kg). Main Outcome Measure(s): Static LEA included pelvic angle, femoral anteversion, quadriceps angle, tibiofemoral angle, genu recurvatum, tibial torsion, and navicular drop. Cluster analysis grouped participants according to their static LEA profiles, and these groups were compared on their hip- and knee-joint kinematics and external moments during the landing phase of a double-legged drop jump. Results: Three distinct clusters (C1–C3) were identified based on their static LEAs. Participants in clusters characterized with static internally rotated hip and valgus knee posture (C1) and externally rotated knee and valgus knee posture (C3) alignments demonstrated greater knee-valgus motion and smaller hip-flexion moments than the cluster with more neutral static alignment (C2). Participants in C1 also experienced greater hip internal-rotation and knee external-rotation moments than those in C2 and C3. Conclusions: Static LEA clusters that are positioned anatomically with a more rotated and valgus knee posture experienced greater dynamic valgus along with hip and knee moments during landing. Whereas static LEA contributes to differences in hip and knee rotational moments, sex may influence the differences in frontal-plane knee kinematics and sagittal-plane hip moments. PMID:25658815
Sueyoshi, Ted; Nakahata, Akihiro; Emoto, Gen; Yuasa, Tomoki
2017-01-01
Background: Isokinetic strength and hop tests are commonly used to assess athletes’ readiness to return to sport after knee surgery. Purpose/Hypothesis: The purpose of this study was to investigate the results of single-leg hop and isokinetic knee strength testing in athletes who underwent anterior cruciate ligament reconstruction (ACLR) upon returning to sport participation as well as to study the correlation between these 2 test batteries. The secondary purpose was to compare the test results by graft type (patellar tendon or hamstring). It was hypothesized that there would be no statistically significant limb difference in either isokinetic knee strength or single-leg hop tests, that there would be a moderate to strong correlation between the 2 test batteries, and that there would be no significant difference between graft types. Study Design: Cross-sectional study; Level of evidence, 3. Methods: Twenty-nine high school and collegiate athletes who underwent ACLR participated in this study. At the time of return to full sport participation, a series of hop tests and knee extension/flexion isokinetic strength measurements were conducted. The results were analyzed using analysis of variance and Pearson correlation (r). Results: The timed 6-m hop test was the only hop test that showed a significant difference between the involved and uninvolved limbs (2.3 and 2.2 seconds, respectively; P = .02). A significant difference between limbs in knee strength was found for flexion peak torque/body weight at 180 deg/s (P = .03), flexion total work/body weight at 180 deg/s (P = .04), and flexion peak torque/body weight at 300 deg/s (P = .03). The strongest correlation between the hop tests and knee strength was found between the total distance of the hop tests and flexion total work/body weight at 300 deg/s (r = 0.69) and between the timed 6-m hop test and flexion peak torque/body weight at 300 deg/s (r = –0.54). There was no statistically significant difference in hop test performance or isokinetic knee strength between graft types. Conclusion: The single-leg hop tests and isokinetic strength measurements were both useful for a bilateral comparison of knee functional performance and strength. Knee flexion strength deficits and flexion-to-extension ratios seemed to be correlated with single-leg hop test performance. There was no difference in postoperative hop test performance or knee strength according to graft type. PMID:29164167
Rasmussen, Matthew T; Nitri, Marco; Williams, Brady T; Moulton, Samuel G; Cruz, Raphael Serra; Dornan, Grant J; Goldsmith, Mary T; LaPrade, Robert F
2016-03-01
Recent investigations have described the structural and functional behavior of the anterolateral ligament (ALL) of the knee through pull-apart and isolated sectioning studies. However, the secondary stabilizing role of the ALL in the setting of a complete anterior cruciate ligament (ACL) tear has not been fully defined for common simulated clinical examinations, such as the pivot-shift, anterior drawer, and internal rotation tests. Combined sectioning of the ALL and ACL would lead to increased internal rotation and increased axial plane translation during a pivot-shift test when compared with isolated sectioning of the ACL. Controlled laboratory study. Ten fresh-frozen human cadaveric knees were subjected to a simulated pivot-shift test with coupled 10-N·m valgus and 5-N·m internal rotation torques from 0° to 60° of knee flexion and a 5-N·m internal rotation torque and an 88-N anterior tibial load, both from 0° to 120° of knee flexion via a 6 degrees of freedom robotic system. Kinematic changes were measured and compared with the intact state for isolated sectioning of the ACL and combined sectioning of the ACL and ALL. Combined sectioning of the ACL and ALL resulted in a significant increase in axial plane tibial translation during a simulated pivot shift at 0°, 15°, 30°, and 60° of knee flexion and a significant increase in internal rotation at 0°, 15°, 30°, 45°, 60°, 75°, 90°, 105°, and 120° when compared with the intact and ACL-deficient states. Based on the model results, ALL sectioning resulted in an additional 2.1 mm (95% CI, 1.4-2.9 mm; P < .001) of axial plane translation during the pivot shift when compared with ACL-only sectioning, when pooling evidence over all flexion angles. Likewise, when subjected to IR torque, the ACL+ALL-deficient state resulted in an additional 3.2° of internal rotation (95% CI, 2.4°-4.1°; P < .001) versus the intact state, and the additional sectioning of the ALL increased internal rotation by 2.7° (95% CI, 1.8°-3.6°; P < .001) versus the ACL-deficient state. The results of this study confirm the ALL as an important lateral knee structure that provides rotatory stability to the knee. Specifically, the ALL was a significant secondary stabilizer throughout flexion during an applied internal rotation torque and simulated pivot-shift test in the context of an ACL-deficient knee. Residual internal rotation and a positive pivot shift after ACL reconstruction may be attributed to ALL injury. For these patients, surgical treatment of an ALL tear may be considered. © 2015 The Author(s).
Flexed-knee gait in children with cerebral palsy.
Church, C; Ge, J; Hager, S; Haumont, T; Lennon, N; Niiler, T; Hulbert, R; Miller, F
2018-04-01
Aims The purpose of this study was to evaluate the long-term outcome of adolescents with cerebral palsy who have undergone single-event multilevel surgery for a flexed-knee gait, followed into young adulthood using 3D motion analysis. Patients and Methods A total of 59 young adults with spastic cerebral palsy, with a mean age of 26 years (sd 3), were enrolled into the study in which their gait was compared with an evaluation that had taken place a mean of 12 years (sd 2) previously. At their visits during adolescence, the children walked with excessive flexion of the knee at initial contact and surgical or therapeutic interventions were not controlled between visits. Results Based on the change in flexed-knee gait over approximately ten years, improvements were seen in increased Gait Deviation Index (p < 0.001) and decreased flexion of the knee at initial contact (p < 0.001). Greater popliteal angle (p < 0.001), reduced Gross Motor Function Measure section D (p = 0.006), and reduced speed of gait (p = 0.007) suggested a mild decline in function. Quality-of-life measures showed that these patients fell within normal limits compared with typical young adults in areas other than physical function. Conclusion While some small significant changes were noted, little clinically significant change was seen in function and gait, with gross motor function maintained between adolescence and young adulthood. Cite this article: Bone Joint J 2018;100-B:549-56.
Intraoperative evaluation of total knee replacement: kinematic assessment with a navigation system.
Casino, Daniela; Zaffagnini, Stefano; Martelli, Sandra; Lopomo, Nicola; Bignozzi, Simone; Iacono, Francesco; Russo, Alessandro; Marcacci, Maurilio
2009-04-01
Interest in the kinematics of reconstructed knees has increased since it was shown that the alteration of knee motion could lead to abnormal wear and damage to soft tissues. We performed intraoperative kinematic measurements using a navigation system to study knee kinematics before and after posterior substituting rotating platform total knee arthroplasty (TKA). We verified intraoperatively (1) if varus/valgus (VV) laxity and anterior/posterior (AP) laxity were restored after TKA; (2) if TKA induced abnormal femoral rollback; and (3) how tibial axial rotation was influenced by TKA throughout the range of flexion. We found that TKA improved alignment in preoperative osteoarthritic varus knees which became neutral after surgery and maintained a neutral alignment in neutral knees. The VV stability at 0 degrees was restored while AP laxity at 90 degrees significantly increased after TKA. Following TKA, the femur had an abnormal anterior translation up to 60 degrees of flexion, followed by a small rollback of 12 +/- 5 mm. TKA influenced the tibia rotation pattern during flexion, but not the total amount of internal/external rotation throughout whole range of flexion, which was preserved after TKA (6 degrees +/- 5 degrees ). This study showed that the protocol proposed might be useful to adjust knee stability at time zero and that knee kinematic outcome during total knee replacement can be monitored by a navigation system.
[Effect of posterior cruciate ligament retaining or not on knee-joint proprioception].
Wu, Yansheng; Li, Yongsheng; Chen, Baicheng
2013-07-01
To analyze the effect of the posterior cruciate ligament (PCL) retaining or not on knee-joint proprioception by comparing the proprioceptive difference between PCL retaining and no PCL retaining in total knee arthroplasty (TKA). Between June 2009 and June 2010, 38 osteoarthritis patients meeting the inclusion criteria were divided into PCL retaining group (group A, n=19) and PCL-substituting group (group B, n=19) according to the random number table. There was no significant difference in gender, age, disease duration, the range of motion of the knee between 2 groups (P > 0.05). The effectiveness and the knee-joint proprioception were separately assessed by the Western Ontario and McMaster University Osteoarthritis Index (WOMAC) score and the passive angle reproduction test (30, 60, and 90 degrees of knee flexion) preoperatively and 12 months postoperatively. All incisons healed by first intention, without complications of infection, fracture, and deep vein thrombosis of lower limb. The patients were followed up 12-17 months (mean, 14.1 months). The knee function after operation was obviously improved when compared with preoperative one; significant differences were observed in the WOMAC scores and the results of passive angle reproduction test between at preoperation and at 12 months after operation (P < 0.05), but no significant difference was found between group A and group B (P > 0.05). Whether PCL retaining or not in TKA both can improve knee-joint proprioception, and no obvious difference between them.
Ankle-Dorsiflexion Range of Motion and Landing Biomechanics
Fong, Chun-Man; Blackburn, J. Troy; Norcross, Marc F.; McGrath, Melanie; Padua, Darin A.
2011-01-01
Abstract Context: A smaller amount of ankle-dorsiflexion displacement during landing is associated with less knee-flexion displacement and greater ground reaction forces, and greater ground reaction forces are associated with greater knee-valgus displacement. Additionally, restricted dorsiflexion range of motion (ROM) is associated with greater knee-valgus displacement during landing and squatting tasks. Because large ground reaction forces and valgus displacement and limited knee-flexion displacement during landing are anterior cruciate ligament (ACL) injury risk factors, dorsiflexion ROM restrictions may be associated with a greater risk of ACL injury. However, it is unclear whether clinical measures of dorsiflexion ROM are associated with landing biomechanics. Objective: To evaluate relationships between dorsiflexion ROM and landing biomechanics. Design: Descriptive laboratory study. Setting: Research laboratory. Patients or Other Participants: Thirty-five healthy, physically active volunteers. Intervention(s): Passive dorsiflexion ROM was assessed under extended-knee and flexed-knee conditions. Landing biomechanics were assessed via an optical motion-capture system interfaced with a force plate. Main Outcome Measure(s): Dorsiflexion ROM was measured in degrees using goniometry. Knee-flexion and knee-valgus displacements and vertical and posterior ground reaction forces were calculated during the landing task. Simple correlations were used to evaluate relationships between dorsiflexion ROM and each biomechanical variable. Results: Significant correlations were noted between extended-knee dorsiflexion ROM and knee-flexion displacement (r = 0.464, P = .029) and vertical (r = −0.411, P = .014) and posterior (r = −0.412, P = .014) ground reaction forces. All correlations for flexed-knee dorsiflexion ROM and knee-valgus displacement were nonsignificant. Conclusions: Greater dorsiflexion ROM was associated with greater knee-flexion displacement and smaller ground reaction forces during landing, thus inducing a landing posture consistent with reduced ACL injury risk and limiting the forces the lower extremity must absorb. These findings suggest that clinical techniques to increase plantar-flexor extensibility and dorsiflexion ROM may be important additions to ACL injury-prevention programs. PMID:21214345
Yamada, Yuzo; Toritsuka, Yukiyoshi; Nakamura, Norimasa; Horibe, Shuji; Sugamoto, Kazuomi; Yoshikawa, Hideki; Shino, Konsei
2017-11-01
The concepts of lateral deviation and lateral inclination of the patella, characterized as shift and tilt, have been applied in combination to evaluate patellar malalignment in patients with patellar dislocation. It is not reasonable, however, to describe the 3-dimensional (3D) positional relation between the patella and the femur according to measurements made on 2-dimensional (2D) images. The current study sought to clarify the relation between lateral deviation and inclination of the patella in patients with recurrent dislocation of the patella (RDP) by redefining them via 3D computer models as 3D shift and 3D tilt. Descriptive laboratory study. Altogether, 60 knees from 56 patients with RDP and 15 knees from 10 healthy volunteers were evaluated. 3D shift and tilt of the patella were analyzed with 3D computer models created by magnetic resonance imaging scans obtained at 10° intervals of knee flexion (0°-50°). 3D shift was defined as the spatial distance between the patellar reference point and the midsagittal plane of the femur; it is expressed as a percentage of the interepicondylar width. 3D tilt was defined as the spatial angle between the patellar reference plane and the transepicondylar axis. Correlations between the 2 parameters were assessed with the Pearson correlation coefficient. The patients' mean Pearson correlation coefficient was 0.895 ± 0.186 (range, -0.073 to 0.997; median, 0.965). In all, 56 knees (93%) had coefficients >0.7 (strong correlation); 1 knee (2%), >0.4 (moderate correlation); 2 knees (3%), >0.2 (weak correlation); and 1 knee (2%), <0.2 (no correlation). The mean correlation coefficient of the healthy volunteers was 0.645 ± 0.448 (range, -0.445 to 0.982; median, 0.834). A statistically significant difference was found in the distribution of the correlation coefficients between the patients and the healthy volunteers ( P = .0034). When distribution of the correlation coefficients obtained by the 3D analyses was compared with that by the 2D (conventional) analyses, based on the bisect offset index and patellar tilt angle, the 3D analyses showed statistically higher correlations between the lateral deviation and inclination of the patella ( P < .01). 3D shift and 3D tilt of the patella were moderately or strongly correlated in 95% of patients with RDP at 0° to 50° of knee flexion. It is not always necessary to use both parameters when evaluating patellar alignment, at least for knees with RDP at 0° to 50° of flexion. Such a description may enable surgeons to describe patellar alignment more simply, leading to a better, easier understanding of the characteristics of each patient with RDP.
Vandenneucker, Hilde; Labey, Luc; Vander Sloten, Jos; Desloovere, Kaat; Bellemans, Johan
2016-11-01
The objectives of this in vitro project were to compare the dynamic three-dimensional patellofemoral kinematics, contact forces, contact areas and contact pressures of a contemporary patellofemoral prosthetic implant with those of the native knee and to measure the influence of patellar resurfacing and patellar thickness. The hypothesis was that these designs are capable to reproduce the natural kinematics but result in higher contact pressures. Six fresh-frozen specimens were tested on a custom-made mechanical knee rig before and after prosthetic trochlear resurfacing, without and with patellar resurfacing in three different patellar thicknesses. Full three-dimensional kinematics were analysed during three different motor tasks, using infrared motion capture cameras and retroflective markers. Patellar contact characteristics were registered using a pressure measuring device. The patellofemoral kinematic behaviour of the patellofemoral arthroplasty was similar to that of the normal knee when the patella was resurfaced, showing only significant (p < 0.0001) changes in patellar flexion. Without patellar resurfacing, significant more patellar flexion, lateral tilt and lateral rotation was noticed. Compared to the normal knee, contact pressures were significantly elevated after isolated trochlear resurfacing. However, the values were more than doubled after patellar resurfacing. Changes in patellar thickness only influenced the antero-posterior patellar position. There was no other influence on the kinematics, and only a limited influence on the contact pressures in the low flexion angles. The investigated design reproduced the normal patellofemoral kinematics acceptable well when the patella was resurfaced. From a kinematic point of view, patellar resurfacing may be advisable. However, the substantially elevated patellar contact pressures remain a point of concern in the decision whether or not to resurface the patella. This study therefore not only adds a new point in the discussion whether or not to resurface the patella, but also supports the claimed advantage that a patellofemoral arthroplasty is capable to reproduce the natural knee kinematics.
Schwarzkopf, Ran; Woolwine, Spencer; Josephs, Lee; Scott, Richard D
2015-12-01
Posterior cruciate ligament (PCL) release may be required to balance the flexion gap in PCL retaining TKA. This study examines the incidence and functional consequences of PCL release in both fixed and mobile bearing TKA. A consecutive series of 1388 TKAs with 1014 fixed bearing, and 374 mobile bearing implants were reviewed for prevalence of partial PCL release, restoration of potential flexion and objective knee stability at minimum one-year follow-up. Patients receiving mobile bearing inserts were more likely to need partial PCL release (42% versus 17.5%). The occurrence of partial PCL release did not have a significant impact on knee range of motion and subjective knee stability. The need for a partial PCL release appears to be greater in mobile than in fixed bearing. Knees that required a release in both groups demonstrated no difference in restoration of flexion compared with unreleased knees and no adverse effects on flexion stability. Copyright © 2015 Elsevier Inc. All rights reserved.
Jung, Hungu; Yamasaki, Masahiro
2016-12-08
Reduced lower extremity range of motion (ROM) and muscle strength are related to functional disability in older adults who cannot perform one or more activities of daily living (ADL) independently. The purpose of this study was to determine which factors of seven lower extremity ROMs and two muscle strengths play dominant roles in the physical performance of community-dwelling older women. Ninety-five community-dwelling older women (mean age ± SD, 70.7 ± 4.7 years; age range, 65-83 years) were enrolled in this study. Seven lower extremity ROMs (hip flexion, hip extension, knee flexion, internal and external hip rotation, ankle dorsiflexion, and ankle plantar flexion) and two muscle strengths (knee extension and flexion) were measured. Physical performance tests, including functional reach test (FRT), 5 m gait test, four square step test (FSST), timed up and go test (TUGT), and five times sit-to-stand test (FTSST) were performed. Stepwise regression models for each of the physical performance tests revealed that hip extension ROM and knee flexion strength were important explanatory variables for FRT, FSST, and FTSST. Furthermore, ankle plantar flexion ROM and knee extension strength were significant explanatory variables for the 5 m gait test and TUGT. However, ankle dorsiflexion ROM was a significant explanatory variable for FRT alone. The amount of variance on stepwise multiple regression for the five physical performance tests ranged from 25 (FSST) to 47% (TUGT). Hip extension, ankle dorsiflexion, and ankle plantar flexion ROMs, as well as knee extension and flexion strengths may play primary roles in the physical performance of community-dwelling older women. Further studies should assess whether specific intervention programs targeting older women may achieve improvements in lower extremity ROM and muscle strength, and thereby play an important role in the prevention of dependence on daily activities and loss of physical function, particularly focusing on hip extension, ankle dorsiflexion, and ankle plantar flexion ROMs as well as knee extension and flexion strength.
Mehta, Saurabh; Rigney, Andrew; Webb, Kyle; Wesney, Jacob; Stratford, Paul W; Shuler, Franklin D; Oliashirazi, Ali
2018-06-13
Retrospective analysis of routinely collected clinical data. This study modeled the recovery in knee flexion and extension range of motion (ROM) over 1 year after total knee replacement (TKR). Recovery after TKR has been characterized for self-reported pain and functional status. Literature describing target knee ROM at different follow-up periods after TKR is scarce. Data were extracted for patients who had undergone TKR at a tertiary care hospital at 2, 8, 12, 26, and 52 weeks after TKR. A linear mixed-effects growth model was constructed that investigated the following covariates age, sex, pre-TKR range, body mass index, duration of symptoms, and their interaction with weeks post TKR. Of the 559 patients included (age 64.8 ± 8.5 years), 370 were women and 189 were men. Knee ROM showed the greatest change during the first 12 weeks after TKR, plateauing by 26 weeks. For an average patient, knee flexion increased from approximately 100º 2 weeks post TKR to 117º 52 weeks post TKR. Knee extension increased from approximately 3º knee flexion 2 weeks post TKR to 1º flexion 52 weeks post TKR. The results showed that the maximum gains in knee ROM should be expected within the first 12 weeks with small changes occurring up to 26 weeks after TKR. In addition, age and presurgery knee ROM are associated with the gains in knee ROM and should be factored into the estimation of expected knee ROM at a given follow-up interval after TKR.
Nowakowski, Andrej Maria; Majewski, Martin; Müller-Gerbl, Magdalena; Valderrabano, Victor
2012-04-01
General agreement is that flexion and extension gaps should be equal and symmetrical in total knee arthroplasty (TKA) procedures. However, comparisons using a standard TKA approach to normal knee joints that have not undergone bone resection are currently unavailable. Since bony preparation can influence capsule and ligament tension, our purpose was to perform measurements without this influence. Ten normal cadaveric knees were assessed using a standard medial parapatellar TKA approach with patellar subluxation. Gap measurements were carried out twice each alternating 100 and 200 N per compartment using a prototypical force-determining ligament balancer without the need for bony resection. Initial measurements were performed in extension, followed by 908 of flexion. The ACL was then resected, and finally the PCL was resected, and measurements were carried out in an analogous fashion. In general, the lateral compartment could be stretched further than the medial compartment, and the corresponding flexion gap values were significantly larger. ACL resection predominantly increased extension gaps, while PCL resection increased flexion gaps. Distraction force of 100 N per compartment appeared adequate; increasing to 200 N did not improve the results.
Murray, Amanda M; Gaffney, Brecca M; Davidson, Bradley S; Christiansen, Cory L
2017-11-01
Lower extremity movement compensations following transtibial amputation are well-documented and are likely influenced by trunk posture and movement. However, the biomechanical compensations of the trunk and lower extremities, especially during high-demand tasks such as step ascent and descent, remain unclear. Kinematic and kinetic data were collected during step ascent and descent tasks for three groups of individuals: diabetic/transtibial amputation, diabetic, and healthy. An ANCOVA was used to compare peak trunk, hip and knee joint angles and moments in the sagittal and frontal planes between groups. Paired t-tests were used to compare peak joint angles and moments between amputated and intact limbs of the diabetic/transtibial amputation group. During step ascent and descent, the transtibial amputation group exhibited greater trunk forward flexion and lateral flexion compared to the other two groups (P<0.016), which resulted in greater low back moments and asymmetric loading patterns in the lower extremity joints. The diabetic group exhibited similar knee joint loading patterns compared to the amputation group (P<0.016), during step descent. This study highlights the biomechanical compensations of the trunk and lower extremities in individuals with dysvascular transtibial amputation, by identifying low back, hip, and knee joint moment patterns unique to transtibial amputation during stepping tasks. In addition, the results suggest that some movement compensations may be confounded by the presence of diabetes and precede limb amputation. The increased and asymmetrical loading patterns identified may predispose individuals with transtibial amputation to the development of secondary pain conditions, such as low back pain or osteoarthritis. Copyright © 2017 Elsevier Ltd. All rights reserved.
Öztürk, Alpaslan; Akalın, Yavuz; Çevik, Nazan; Otuzbir, Ali; Özkan, Yüksel; Dostabakan, Yasin
2016-07-01
Posterior cruciate retention (CR) and substitution (PS) has been controversial in knee replacement surgery. Satisfactory medium and long-term results have been reported in knees with and without deformity but there are limited studies about early functional comparison in terms of recovery of flexion arc, stair activity, walking ability and straight leg raising, especially, in early postoperative period in knees with deformity. Therefore, we aimed to compare the flexion arc in CR and PS knees in postoperative first year including early postoperative days prospectively. Consecutive patients with a deformity of >10° were included and allocated to CR and PS groups randomly. KSS and Feller-patella scores were recorded both preoperatively and postoperatively (1st, 2nd, 3rd and 12th months). Flexion and extension were measured both preoperatively and postoperatively (1st, 2nd, 3rd day and discharge day as well as 1st, 2nd, 3rd and 12th months). Visual analog scale (VAS) was recorded postoperatively at the 1st, 2nd, 3rd and discharge day and at 1st, 2nd, 3rd and 12th months. The walking ability, stair activity and straight leg raising were recorded. Patients were also examined at the last visit with minimum 7-year follow-up with KSS, Feller-patella and VAS scores. Their mean flexion arcs were measured and recorded. There were 61 TKR evaluated. KSS knee and function scores at the 3rd month and KSS Knee Score at 1st year were superior in PS knees (p = 0.029, p = 0.046, p = 0.026). Flexion arc was found larger on day 1, 2, 3 and discharge day, and at 1st, 2nd, 3rd and 12th month in PS group (p = 0.048, p = 0.002, p = 0.027, p = 0.043, p = 0.014, p = 0.003, p = 0.002, p = 0.018). Walking and stair activity showed no difference but straight leg raising was better in CR knees (p = 0.02). Mean flexion arc was larger in PS knees at the last visit after 7 years (119.0° ± 7.5° in PS and 113.8° ± 8.7° in CR, p = 0.02). There was no revision required in that time interval. The other parameters were similar between groups. PS knees gained active flexion arc faster and larger. But straight leg raising activity recovered early in CR knees. Both types of prosthesis produced satisfactory outcome. PS and CR TKRs can be performed with the same performance in osteoarthritic knees even with high varus deformity. Prospective Randomized Controlled Trial, Level II.
Cordeiro, Nuno; Cortes, Nelson; Fernandes, Orlando; Diniz, Ana; Pezarat-Correia, Pedro
2015-04-01
The instep soccer kick is a pre-programmed ballistic movement with a typical agonist-antagonist coordination pattern. The coordination pattern of the kick can provide insight into deficient neuromuscular control. The purpose of this study was to investigate knee kinematics and hamstrings/quadriceps coordination pattern during the knee ballistic extension phase of the instep kick in soccer players after anterior cruciate ligament reconstruction (ACL reconstruction). Seventeen players from the Portuguese Soccer League participated in this study. Eight ACL-reconstructed athletes (experimental group) and 9 healthy individuals (control group) performed three instep kicks. Knee kinematics (flexion and extension angles at football contact and maximum velocity instants) were calculated during the kicks. Rectus femoris (RF), vastus lateralis, vastus medialis, biceps femoralis, and semitendinosus muscle activations were quantified during the knee extension phase. The ACL-reconstructed group had significantly lower knee extension angle (-1.2 ± 1.6, p < 0.021) and increased variability (1.1 ± 1.2, p < 0.012) when compared with the control group. Within the EMG variables, the RF had a significantly greater activity in the ACL-reconstructed group than in the control group (79.9 ± 27.7 % MVC vs. 49.2 ± 20.8 % MVC, respectively, p < 0.034). No other statistically significant differences were found. The findings of this study demonstrate that changes in ACL-reconstructed individuals were observed on knee extension angle and RF muscle activation while performing an instep kick. These findings are in accordance with the knee stability recovery process after ACL reconstruction. No differences were observed in the ballistic control movement pattern between normal and ACL-reconstructed subjects. Performing open kinetic chain exercises using ballistic movements can be beneficial when recovering from ACL reconstruction. The exercises should focus on achieving multi-joint coordination and full knee extension (range of motion). III.
Kim, Kew-Wan; Lim, Bee-Oh
2014-11-01
Although numerous studies have demonstrated the relationship between maturation and lower extremity biomechanics during landing in team sport athletes, we are presently uninformed of any research that examined the single-legged drop landing biomechanics of gymnasts. The purpose of this study is to investigate the effects of the menarcheal age on the lower extremity biomechanics during a single-legged drop landing in female artistic elite gymnasts. Twenty-two female artistic elite gymnasts, between 9 and 36 years of age, participated in this study. The participants were divided into two groups pre- (n = 11) and post- (n = 11) menarche and asked to perform a single-legged drop landing on top of a 30 cm platform and land on a force plate. The statistical analysis consisted of the multivariate analysis with the level of significance set at p < 0.05. The post-menarche group showed a decrease in their maximum knee flexion angle and increase in their maximum knee abduction angle, maximum internal tibial rotation angle, maximum knee abduction moment, and hamstring-quadriceps muscle activity ratio compared with the pre-menarche group during the single-legged drop landing. The post-menarche group showed an increased noncontact anterior cruciate ligament injury risk, due to their greater knee loads, compared with the pre-menarche group.
Does patella lowering improve crouch gait in cerebral palsy? Comparative retrospective study.
Desailly, E; Thévenin-Lemoine, C; Khouri, N
2017-09-01
Patella lowering aims to improve quadriceps function as a means of correcting crouch gait in patients with cerebral palsy. Few studies have assessed the effects of patella lowering as a component of multilevel surgery. Including patella lowering into the components of multilevel surgery is beneficial in patients with crouch gait and patella alta. In 12 lower limbs with patella alta (Caton-Deschamps index>1.4) in 41 children with cerebral palsy, patella lowering was performed, without distal femoral extension osteotomy or hamstring release. Among limbs with similar surgical procedures (e.g., hamstring lengthening, rectus femoris transfer) except for patella lowering, controls were selected retrospectively by matching on a propensity score for patella lowering. The propensity score was computed based on preoperative knee flexion contracture, knee extension lag, and minimum knee flexion at mid-stance. Clinical and 3D kinematic data were compared between the two groups. The improvement in minimum knee flexion at mid-stance was significantly greater in the group with patellar lowering (-24°±12°vs. -12°±7°). The Gait Deviation Index improved similarly in the two groups. Knee flexion contracture improved only in the group with patellar lowering. Extension lag did not improve in either group. Peak knee flexion during the swing phase remained unchanged in both groups. Patellar lowering is effective in diminishing minimum knee flexion at mid-stance in patients with patella alta and crouch gait due to cerebral palsy. Patellar lowering has not adverse effects on gait. These findings cannot be assumed to apply to patients with normal patellar height. IV (retrospective study). Copyright © 2017. Published by Elsevier Masson SAS.
Allan, Richard; Woodburn, James; Telfer, Scott; Abbott, Mandy; Steultjens, Martijn Pm
2017-06-01
The knee adduction moment is consistently used as a surrogate measure of medial compartment loading. Foot orthoses are designed to reduce knee adduction moment via lateral wedging. The 'dose' of wedging required to optimally unload the affected compartment is unknown and variable between individuals. This study explores a personalised approach via three-dimensional printed foot orthotics to assess the biomechanical response when two design variables are altered: orthotic length and lateral wedging. Foot orthoses were created for 10 individuals with symptomatic medial knee osteoarthritis and 10 controls. Computer-aided design software was used to design four full and four three-quarter-length foot orthoses per participant each with lateral posting of 0° 'neutral', 5° rearfoot, 10° rearfoot and 5° forefoot/10° rearfoot. Three-dimensional printers were used to manufacture all foot orthoses. Three-dimensional gait analyses were performed and selected knee kinetics were analysed: first peak knee adduction moment, second peak knee adduction moment, first knee flexion moment and knee adduction moment impulse. Full-length foot orthoses provided greater reductions in first peak knee adduction moment (p = 0.038), second peak knee adduction moment (p = 0.018) and knee adduction moment impulse (p = 0.022) compared to three-quarter-length foot orthoses. Dose effect of lateral wedging was found for first peak knee adduction moment (p < 0.001), second peak knee adduction moment (p < 0.001) and knee adduction moment impulse (p < 0.001) indicating greater unloading for higher wedging angles. Significant interaction effects were found for foot orthosis length and participant group in second peak knee adduction moment (p = 0.028) and knee adduction moment impulse (p = 0.036). Significant interaction effects were found between orthotic length and wedging condition for second peak knee adduction moment (p = 0.002). No significant changes in first knee flexion moment were found. Individual heterogeneous responses to foot orthosis conditions were observed for first peak knee adduction moment, second peak knee adduction moment and knee adduction moment impulse. Biomechanical response is highly variable with personalised foot orthoses. Findings indicate that the tailoring of a personalised intervention could provide an additional benefit over standard interventions and that a three-dimensional printing approach to foot orthosis manufacturing is a viable alternative to the standard methods.
Kim, Young-Hoo; Park, Jang-Won; Kim, Jun-Shik
2018-01-01
There is none, to our knowledge, about comparison of high-flexion fixed-bearing and high-flexion mobile-bearing total knee arthroplasties (TKAs) in the same patients. The purpose of this study was to determine whether clinical results; radiographic and computed tomographic scan results; and the survival rate of a high-flexion mobile-bearing TKA is better than that of a high-flexion fixed-bearing TKA. The present study consisted of 92 patients (184 knees) who underwent same-day bilateral TKA. Of those, 17 were men and 75 were women. The mean age at the time of index arthroplasty was 61.5 ± 8.3 years (range 52-65 years). The mean body mass index was 26.2 ± 3.3 kg/m 2 (range 23-34 kg/m 2 ). The mean follow-up was 11.2 years (range 10-12 years). The Knee Society knee scores (93 vs 92 points; P = .531) and function scores (80 vs 80 points; P = 1.000), WOMAC scores (14 vs 15 points; P = .972), and UCLA activity scores (6 vs 6 points; P = 1.000) were not different between the 2 groups at 12 years follow-up. There were no differences in any radiographic and CT scan parameters between the 2 groups. Kaplan-Meier survivorship of the TKA component was 98% (95% confidence interval, 93-100) in the high-flexion fixed-bearing TKA group and 99% (95% confidence interval, 94-100) in the high-flexion mobile-bearing TKA group 12 years after the operation. We found no benefit to mobile-bearing TKA in terms of pain, function, radiographic and CT scan results, and survivorship. Longer-term follow-up is necessary to prove the benefit of the high-flexion mobile-bearing TKA over the high-flexion fixed-bearing TKA. Copyright © 2017 Elsevier Inc. All rights reserved.
Al-Oraibi, S; Tariah, Hashem Abu; Alanazi, Abdullah
2013-01-01
Severe knee contractures that develop soon after muscle imbalance may not improve with stretching exercises and splinting. An alternative treatment is serial casting, which has been used to promote increased range of motion. The purpose of this study was to compare the effectiveness of using serial casting and passive stretching approaches to treat knee flexion contracture in children with spina bifida. In a pre/post randomized controlled study, ten participants were included in the serial casting group, while eight participants were included in the passive stretching intervention group. The degree of knee extension was measured at baseline, immediately after intervention, and at a one-year follow-up using a standard goniometer. Both groups showed significant improvements in the degree of flexion contracture at the post-treatment evaluation and the follow-up evaluation. The serial casting group showed significant improvements in knee flexion contracture at the post-treatment evaluation, t (9)=13.4, p < 0.001, and the one-year follow-up evaluation, t (9) = 7.46, p < 0.001. The passive stretching group also showed significant improvements in knee flexion contracture at the post-treatment evaluation, t (7) =2.6, p < 0.05, and the one-year follow-up evaluation, t (7) = 3.6, p < 0.05. However, statistically significant improvements in the serial casting group compared with passive stretching group in relation to the degree of flexion contracture were found at the immediate post-treatment evaluation, F(1, 15)=246, p=0.0001, and the one-year follow-up evaluation, F (1, 15)=51.5, p=0.0001. The outcomes of this study provide the first evidence that serial casting may be a useful intervention in treating knee flexion contracture in children with spina bifida. However, further investigations into serial casting, as well as investigations into the use of serial casting with other interventions, are warranted.
Neuromuscular adaptations induced by adjacent joint training.
Ema, R; Saito, I; Akagi, R
2018-03-01
Effects of resistance training are well known to be specific to tasks that are involved during training. However, it remains unclear whether neuromuscular adaptations are induced after adjacent joint training. This study examined the effects of hip flexion training on maximal and explosive knee extension strength and neuromuscular performance of the rectus femoris (RF, hip flexor, and knee extensor) compared with the effects of knee extension training. Thirty-seven untrained young men were randomly assigned to hip flexion training, knee extension training, or a control group. Participants in the training groups completed 4 weeks of isometric hip flexion or knee extension training. Standardized differences in the mean change between the training groups and control group were interpreted as an effect size, and the substantial effect was assumed to be ≥0.20 of the between-participant standard deviation at baseline. Both types of training resulted in substantial increases in maximal (hip flexion training group: 6.2% ± 10.1%, effect size = 0.25; knee extension training group: 20.8% ± 9.9%, effect size = 1.11) and explosive isometric knee extension torques and muscle thickness of the RF in the proximal and distal regions. Improvements in strength were accompanied by substantial enhancements in voluntary activation, which was determined using the twitch interpolation technique and RF activation. Differences in training effects on explosive torques and neural variables between the two training groups were trivial. Our findings indicate that hip flexion training results in substantial neuromuscular adaptations during knee extensions similar to those induced by knee extension training. © 2017 The Authors. Scandinavian Journal of Medicine & Science In Sports Published by John Wiley & Sons Ltd.
Lorenz, Andrea; Bobrowitsch, Evgenij; Wünschel, Markus; Walter, Christian; Wülker, Nikolaus; Leichtle, Ulf G
2015-07-23
Anterior knee pain is often associated with patellar maltracking and instability. However, objective measurement of patellar stability under clinical and experimental conditions is difficult, and muscular activity influences the results. In the present study, a new experimental setting for in vitro measurement of patellar stability was developed and the mediolateral force-displacement behavior of the native knee analyzed with special emphasis on patellar tilt and muscle loading. In the new experimental setup, two established testing methods were combined: an upright knee simulator for positioning and loading of the knee specimens, and an industry robot for mediolateral patellar displacement. A minimally invasive coupling and force control mechanism enabled unconstrained motion of the patella as well as measurement of patellar motion in all six degrees of freedom via an external ultrasonic motion-tracking system. Lateral and medial patellar displacement were measured on seven fresh-frozen human knee specimens in six flexion angles with varying muscle force levels, muscle force distributions, and displacement forces. Substantial repeatability was achieved for patellar shift (ICC(3,1) = 0.67) and tilt (ICC(3,1) = 0.75). Patellar lateral and medial shift decreased slightly with increasing flexion angle. Additional measurement of patellar tilt provided interesting insights into the different displacement mechanisms in lateral and medial directions. For lateral displacement, the patella tilted in the same (lateral) direction, and tilted in the opposite direction (again laterally) for medial displacement. With regard to asymmetric muscle loading, a significant influence (p < 0.03, up to 5 mm shift and 8° tilt) was found for lateral displacement and a reasonable relationship between muscle and patellar force, whereas no effect was visible in the medial direction. The developed experimental setup delivered reproducible results and was found to be an excellent testing method for the in vitro analysis of patellar stability and future investigation of surgical techniques for patellar stabilization and total knee arthroplasty. We demonstrated a significant influence of asymmetric quadriceps loading on patellar stability. In particular, increased force application on the vastus lateralis muscle led to a clear increase of lateral patellar displacement.
Tsukada, Sachiyuki; Wakui, Motohiro; Hoshino, Akiho
2014-09-03
Although epidural analgesia has been used for postoperative pain control after total knee arthroplasty, its usefulness is being reevaluated because of possible adverse effects. Recent studies have proven the efficacy of periarticular analgesic injection and its low prevalence of adverse effects. The present study compares the clinical efficacies of epidural analgesia and periarticular injection after total knee arthroplasty. This is a prospective, single-center, randomized controlled trial involving patients scheduled for unilateral total knee arthroplasty. One hundred and eleven patients were randomly assigned to periarticular injection or epidural analgesia groups. All patients were managed with spinal anesthesia. The surgical technique and postoperative medication protocol were identical in both groups. The primary outcome was postoperative pain at rest, quantified as the area under the curve of the scores on a visual analog pain scale to seventy-two hours postoperatively. The Student t test and chi-square test were used to compare the data between groups. In the intention-to-treat analysis, the periarticular injection group had a significantly lower area under the curve for pain score at rest (788.0 versus 1065.9; p = 0.0059). In the periarticular injection group, the mean knee flexion angle was small but significantly better at postoperative day 1 (64.2° versus 54.6°; p = 0.0072) and postoperative day 2 (70.3° versus 64.6°; p = 0.021) than in the epidural analgesia group. The incidence of nausea at postoperative day 1 was significantly lower in the periarticular injection group (4.0% versus 44.3%; p < 0.0001). Transient peroneal nerve palsy was frequently seen in the periarticular injection group (12.0% versus 1.6%; p = 0.026). Compared with epidural analgesia, periarticular injection offers better postoperative pain relief, earlier recovery of knee flexion angle, and lower incidence of nausea. Care should be taken to avoid transient peroneal nerve palsy when using periarticular injection. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.
Celebrini, Richard G.; Eng, Janice J.; Miller, William C.; Ekegren, Christina L.; Johnston, James D.; Depew, Thomas A.; MacIntyre, Donna L.
2015-01-01
Objective To determine the effect of a novel movement strategy incorporated within a soccer warm-up on biomechanical risk factors for ACL injury during three sport-specific movement tasks. Design Single-blind, randomized controlled clinical trial. Setting Laboratory setting. Participants 20 top-tier female teenage soccer players. Interventions Subjects were randomized to the Core Position and Control movement strategy (Core-PAC) warm-up or standard warm-up which took place prior to their regular soccer practice over a 6-week period. The Core-PAC focuses on getting the centre of mass closer to the plant foot or base of support. Main Outcome Measures Peak knee flexion angle and abduction moments during a side-hop (SH), side-cut (SC) and unanticipated side-cut (USC) task after the 6-weeks with (intervention group only) and without a reminder to use the Core-PAC strategy. Results The Core-PAC group increased peak flexion angles during the SH task (Mean difference = 6.2°, 95% CI: 1.9–10.5°, effect size = 1.01, P = 0.034) after the 6-week warm-up program without a reminder. In addition, the Core-PAC group demonstrated increased knee flexion angles for the side-cut (Mean difference = 8.5°, 95% CI: 4.8–12.2°, ES = 2.02, P = 0.001) and side-hop (Mean difference = 10.0°, 95% CI: 5.7–14.3°, ES = 1.66, P = 0.001) task after a reminder. No changes in abduction moments were found. Conclusions The results of this study suggest that the Core-PAC may be one method of modifying high-risk soccer-specific movements and can be implemented within a practical, team-based soccer warm-up. The results should be interpreted with caution due to the small sample size. PMID:24184850
Mechanisms of ACL injury in professional rugby union: a systematic video analysis of 36 cases.
Montgomery, Connor; Blackburn, Jeff; Withers, Daniel; Tierney, Gregory; Moran, Cathal; Simms, Ciaran
2016-12-30
The mechanisms of ACL injury in rugby are not well defined. To describe the mechanisms of ACL injury in male professional rugby players using systematic video analysis. 36 cases from games played in top professional leagues and international matches were analysed. 5 analysts independently assessed all videos to record the estimated frame/time of initial ground contact, frame/time of ACL tear and a range of play specific variables. This included contact versus non-contact ACL injuries, injury timing, joint flexion angles and foot contact with the ground. 37 side-stepping manoeuvres from a control game were analysed to allow comparison of non-injury versus injury situations. 57% of ACL injuries occurred in a contact manner. 2 main scenarios were identified: (1) offensive running and (2) being tackled, indicating that the ball carrier might be at higher risk of ACL injury. The majority of non-contact ACL injuries resulted from a side-stepping manoeuvre. In most non-contact cases, initial ground contact was through heel strike. Statistical assessment of heel strike at initial ground contact versus non-heel strike cases showed a significant difference in injury versus non-injury outcomes, with heel strike associated with higher injury risk. Non-contact ACL injuries had lower median knee flexion angles and a more dorsiflexed ankle when compared with a control group (10° vs 20°, p≤0.001 and 10° vs 0°, p=0.033 respectively). Over half of ACL injuries in rugby in our analysis resulted from a contact mechanism. For non-contact injuries, lower knee flexion angles and heel-first ground contact in a side-stepping manoeuvre were associated with ACL injury. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Strain measurements of the tibial insert of a knee prosthesis using a knee motion simulator.
Sera, Toshihiro; Iwai, Yuya; Yamazaki, Takaharu; Tomita, Tetsuya; Yoshikawa, Hideki; Naito, Hisahi; Matsumoto, Takeshi; Tanaka, Masao
2017-12-01
The longevity of a knee prosthesis is influenced by the wear of the tibial insert due to its posture and movement. In this study, we assumed that the strain on the tibial insert is one of the main reasons for its wear and investigated the influence of the knee varus-valgus angles on the mechanical stress of the tibial insert. Knee prosthesis motion was simulated using a knee motion simulator based on a parallel-link six degrees-of-freedom actuator and the principal strain and pressure distribution of the tibial insert were measured. In particular, the early stance phase obtained from in vivo X-ray images was examined because the knee is applied to the largest load during extension/flexion movement. The knee varus-valgus angles were 0° (neutral alignment), 3°, and 5° malalignment. Under a neutral orientation, the pressure was higher at the middle and posterior condyles. The first and second principal strains were larger at the high and low pressure areas, respectively. Even for a 3° malalignment, the load was concentrated at one condyle and the positive first principal strain increased dramatically at the high pressure area. The negative second principal strain was large at the low pressure area on the other condyle. The maximum equivalent strain was 1.3-2.1 times larger at the high pressure area. For a 5° malalignment, the maximum equivalent strain increased slightly. These strain and pressure measurements can provide the mechanical stress of the tibial insert in detail for determining the longevity of an artificial knee joint.
Does trampoline or hard surface jumping influence lower extremity alignment?
Akasaka, Kiyokazu; Tamura, Akihiro; Katsuta, Aoi; Sagawa, Ayako; Otsudo, Takahiro; Okubo, Yu; Sawada, Yutaka; Hall, Toby
2017-12-01
[Purpose] To determine whether repetitive trampoline or hard surface jumping affects lower extremity alignment on jump landing. [Subjects and Methods] Twenty healthy females participated in this study. All subjects performed a drop vertical jump before and after repeated maximum effort trampoline or hard surface jumping. A three-dimensional motion analysis system and two force plates were used to record lower extremity angles, moments, and vertical ground reaction force during drop vertical jumps. [Results] Knee extensor moment after trampoline jumping was greater than that after hard surface jumping. There were no significant differences between trials in vertical ground reaction force and lower extremity joint angles following each form of exercise. Repeated jumping on a trampoline increased peak vertical ground reaction force, hip extensor, knee extensor moments, and hip adduction angle, while decreasing hip flexion angle during drop vertical jumps. In contrast, repeated jumping on a hard surface increased peak vertical ground reaction force, ankle dorsiflexion angle, and hip extensor moment during drop vertical jumps. [Conclusion] Repeated jumping on the trampoline compared to jumping on a hard surface has different effects on lower limb kinetics and kinematics. Knowledge of these effects may be useful in designing exercise programs for different clinical presentations.
Does trampoline or hard surface jumping influence lower extremity alignment?
Akasaka, Kiyokazu; Tamura, Akihiro; Katsuta, Aoi; Sagawa, Ayako; Otsudo, Takahiro; Okubo, Yu; Sawada, Yutaka; Hall, Toby
2017-01-01
[Purpose] To determine whether repetitive trampoline or hard surface jumping affects lower extremity alignment on jump landing. [Subjects and Methods] Twenty healthy females participated in this study. All subjects performed a drop vertical jump before and after repeated maximum effort trampoline or hard surface jumping. A three-dimensional motion analysis system and two force plates were used to record lower extremity angles, moments, and vertical ground reaction force during drop vertical jumps. [Results] Knee extensor moment after trampoline jumping was greater than that after hard surface jumping. There were no significant differences between trials in vertical ground reaction force and lower extremity joint angles following each form of exercise. Repeated jumping on a trampoline increased peak vertical ground reaction force, hip extensor, knee extensor moments, and hip adduction angle, while decreasing hip flexion angle during drop vertical jumps. In contrast, repeated jumping on a hard surface increased peak vertical ground reaction force, ankle dorsiflexion angle, and hip extensor moment during drop vertical jumps. [Conclusion] Repeated jumping on the trampoline compared to jumping on a hard surface has different effects on lower limb kinetics and kinematics. Knowledge of these effects may be useful in designing exercise programs for different clinical presentations. PMID:29643592
Ebert, Jay R; Joss, Brendan; Jardine, Berit; Wood, David J
2013-11-01
To investigate the efficacy of manual lymphatic drainage (MLD) in the early postoperative period after total knee arthroplasty (TKA) to reduce edema and pain and improve knee range of motion. Prospective randomized controlled trial. Private hospital and functional rehabilitation clinic. Consecutive sample of patients (N=43; 53 knees) scheduled for TKA. MLD (vs no MLD) on days 2, 3, and 4 postoperatively. Both groups underwent conventional, concomitant physical therapy. Clinical assessment was undertaken pre- and postoperatively prior to and after the designated postoperative MLD sessions (days 2, 3, and 4) and at 6 weeks postsurgery. This included active knee flexion and extension range of motion, lower limb girths (ankle, midpatella, thigh, and calf), and knee pain using a numeric rating scale and the Knee Injury and Osteoarthritis Outcome Score. A significant group effect was observed for active knee flexion, with post hoc tests demonstrating a significantly greater active knee flexion in the MLD group when compared with the control (no MLD) group at the final measure prior to hospital discharge (day 4 postsurgery) and at 6 weeks postsurgery. There were no further group effects observed for the remaining patient-reported and functional outcomes. MLD in the early postoperative stages after TKA appears to improve active knee flexion up to 6 weeks postsurgery, in addition to conventional care. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Reliability of a smartphone-based goniometer for knee joint goniometry.
Ferriero, Giorgio; Vercelli, Stefano; Sartorio, Francesco; Muñoz Lasa, Susana; Ilieva, Elena; Brigatti, Elisa; Ruella, Carolina; Foti, Calogero
2013-06-01
The aim of this study was to assess the reliability of a smartphone-based application developed for photographic-based goniometry, DrGoniometer (DrG), by comparing its measurement of the knee joint angle with that made by a universal goniometer (UG). Joint goniometry is a common mode of clinical assessment used in many disciplines, in particular in rehabilitation. One validated method is photographic-based goniometry, but the procedure is usually complex: the image has to be downloaded from the camera to a computer and then edited using dedicated software. This disadvantage may be overcome by the new generation of mobile phones (smartphones) that have computer-like functionality and an integrated digital camera. This validation study was carried out under two different controlled conditions: (i) with the participant to measure in a fixed position and (ii) with a battery of pictures to assess. In the first part, four raters performed repeated measurements with DrG and UG at different knee joint angles. Then, 10 other raters measured the knee at different flexion angles ranging 20-145° on a battery of 35 pictures taken in a clinical setting. The results showed that inter-rater and intra-rater correlations were always more than 0.958. Agreement with the UG showed a width of 18.2° [95% limits of agreement (LoA)=-7.5/+10.7°] and 14.1° (LoA=-6.6/+7.5°). In conclusion, DrG seems to be a reliable method for measuring knee joint angle. This mHealth application can be an alternative/additional method of goniometry, easier to use than other photographic-based goniometric assessments. Further studies are required to assess its reliability for the measurement of other joints.
Wiley, Marcel R; Riccio, Anthony I; Felton, Kevin; Rodgers, Jennifer A; Wimberly, Robert L; Johnston, Charles E
Quengel casting was introduced in 1922 for nonsurgical treatment of knee flexion contractures (KFC) associated with hemophilic arthropathy. It consists of an extension-desubluxation hinge fixed to a cast allowing for gradual correction of a flexion deformity while preventing posterior tibial subluxation. The purpose of this study is to report 1 center's experience with this technique for the treatment of pediatric KFC. A retrospective review was conducted over a 26-year period. All patients with KFC treated with Quengel casting were included. Demographic data, associated medical conditions, adjunctive soft tissue releases, complications, and the need for late surgical intervention were recorded. Tibiofemoral angle measurements in maximal extension were recorded at initiation and termination of casting, 1-year follow-up, and final follow-up. Success was defined as no symptomatic recurrence of KFC or need for subsequent surgery. Eighteen patients (26 knees) were treated for KFC with Quengel casting. Average age at initiation of casting was 8.1 years with average follow-up of 59.9 months. Fifteen knees (58%) underwent soft tissue releases before casting. An average of 1.5 casts per knee were applied over an average of 23.9 days. Average KFC before casting was 50.6 degrees (range, 15 to 100 degrees) which improved to 5.96 degrees (0 to 40 degrees) at cast removal (P<0.00001). Sixteen patients (22 knees) had 1-year follow-up or failed casting before 1 year. Of these, 11 knees (50%) had a successful outcome. Residual KFC of those treated successfully was 6.8 degrees (range, 0 to 30 degrees) at 1 year and 8.2 degrees (range, 0 to 30 degrees) at final follow-up, averaging 71.4 months (P=0.81). Of the 11 knees deemed failures, all had recurrence of deformity within an average of 1 year from cast removal. Surgical release before Quengel casting did not improve the chances for success (P=0.09). Quengel casting can improve pediatric KFC an average of 44.2 degrees with minimal complications. Although 50% of treated patients will demonstrate significant recurrence or need later surgery, the majority of those treated successfully have durable results at intermediate term follow-up. Level IV-therapeutic study.
Baltzopoulos, Vasilios; Richards, Paula J.; Maganaris, Constantinos N.
2011-01-01
The purpose of this study was to determine the effect of dynamometer and joint axis misalignment on measured isometric knee-extension moments using inverse dynamics based on the actual joint kinematic information derived from the real-time X-ray video and to compare the errors when the moments were calculated using measurements from external anatomical surface markers or obtained from the isokinetic dynamometer. Six healthy males participated in this study. They performed isometric contractions at 90° and 20° of knee flexion, gradually increasing to maximum effort. For the calculation of the actual knee-joint moment and the joint moment relative to the knee-joint center, determined using the external marker, two free body diagrams were used of the Cybex arm and the lower leg segment system. In the first free body diagram, the mean center of the circular profiles of the femoral epicondyles was used as the knee-joint center, whereas in the second diagram, the joint center was assumed to coincide with the external marker. Then, the calculated knee-joint moments were compared with those measured by the dynamometer. The results indicate that 1) the actual knee-joint moment was different from the dynamometer recorded moment (difference ranged between 1.9% and 4.3%) and the moment calculated using the skin marker (difference ranged between 2.5% and 3%), and 2) during isometric knee extension, the internal knee angle changed significantly from rest to the maximum contraction state by about 19°. Therefore, these differences cannot be neglected if the moment–knee-joint angle relationship or the muscle mechanical properties, such as length-tension relationship, need to be determined. PMID:21474701
Park, Sang-Kyoon; Kobsar, Dylan; Ferber, Reed
2016-10-01
The relationship between muscle strength, gait biomechanics, and self-reported physical function and pain for patients with knee osteoarthritis is not well known. The objective of this study was to investigate these relationships in this population. Twenty-four patients with knee osteoarthritis and 24 healthy controls were recruited. Self-reported pain and function, lower-limb maximum isometric force, and frontal plane gait kinematics during treadmill walking were collected on all patients. Between-group differences were assessed for 1) muscle strength and 2) gait biomechanics. Linear regressions were computed within the knee osteoarthritis group to examine the effect of muscle strength on 1) self-reported pain and function, and 2) gait kinematics. Patients with knee osteoarthritis exhibited reduced hip external rotator, knee extensor, and ankle inversion muscle force output compared with healthy controls, as well as increased peak knee adduction angles (effect size=0.770; p=0.013). Hip abductor strength was a significant predictor of function, but not after controlling for covariates. Ankle inversion, hip abduction, and knee flexion strength were significant predictors of peak pelvic drop angle after controlling for covariates (34.4% unique variance explained). Patients with knee osteoarthritis exhibit deficits in muscle strength and while they play an important role in the self-reported function of patients with knee osteoarthritis, the effect of covariates such as sex, age, mass, and height was more important in this relationship. Similar relationships were observed from gait variables, except for peak pelvic drop, where hip, knee, and ankle strength remained important predictors of this variable after controlling for covariates. Copyright © 2016 Elsevier Ltd. All rights reserved.
Range of Motion of the Ankle According to Pushing Force, Gender and Knee Position.
Cho, Kang Hee; Jeon, Yumi; Lee, Hyunkeun
2016-04-01
To investigate the difference of range of motion (ROM) of ankle according to pushing force, gender and knee position. One hundred and twenty-eight healthy adults (55 men, 73 women) between the ages of 20 and 51, were included in the study. One examiner measured the passive range of motion (PROM) of ankle by Dualer IQ Inclinometers and Commander Muscle Testing. ROM of ankle dorsiflexion (DF) and plantarflexion (PF) according to change of pushing force and knee position were measured at prone position. There was significant correlation between ROM and pushing force, the more pushing force leads the more ROM at ankle DF and ankle PF. Knee flexion of 90° position showed low PF angle and high ankle DF angle, as compared to the at neutral position of knee joint. ROM of ankle DF for female was greater than for male, with no significant difference. ROM of ankle PF for female was greater than male regardless of the pushing force. To our knowledge, this is the first study to assess the relationship between pushing force and ROM of ankle joint. There was significant correlation between ROM of ankle and pushing force. ROM of ankle PF for female estimated greater than male regardless of the pushing force and the number of measurement. The ROM of the ankle is measured differently according to the knee joint position. Pushing force, gender and knee joint position are required to be considered when measuring the ROM of ankle joint.
Beutler, Anthony I.; de la Motte, Sarah J.; Marshall, Stephen W.; Padua, Darin A.; Boden, Barry P.
2009-01-01
Recent studies have focused on gender differences in movement patterns as risk factors for ACL injury. Understanding intrinsic and extrinsic factors which contribute to movement patterns is critical to ACL injury prevention efforts. Isometric lower- extremity muscular strength, anthropometrics, and jump-landing technique were analyzed for 2,753 cadets (1,046 female, 1,707 male) from the U.S. Air Force, Military and Naval Academies. Jump- landings were evaluated using the Landing Error Scoring System (LESS), a valid qualitative movement screening tool. We hypothesized that distinct anthropometric factors (Q-angle, navicular drop, bodyweight) and muscle strength would predict poor jump-landing technique in males versus females, and that female cadets would have higher scores (more errors) on a qualitative movement screen (LESS) than males. Mean LESS scores were significantly higher in female (5.34 ± 1.51) versus male (4.65 ± 1.69) cadets (p < 0.001). Qualitative movement scores were analyzed using factor analyses, yielding five factors, or “patterns”, contributing to poor landing technique. Females were significantly more likely to have poor technique due to landing with less hip and knee flexion at initial contact (p < 0.001), more knee valgus with wider landing stance (p < 0. 001), and less flexion displacement over the entire landing (p < 0.001). Males were more likely to have poor technique due to landing toe-out (p < 0.001), with heels first, and with an asymmetric foot landing (p < 0.001). Many of the identified factor patterns have been previously proposed to contribute to ACL injury risk. However, univariate and multivariate analyses of muscular strength and anthropometric factors did not strongly predict LESS scores for either gender, suggesting that changing an athlete’s alignment, BMI, or muscle strength may not directly improve his or her movement patterns. Key points Important differences in male and female landing technique can be captured using a qualitative movement screen: the Landing Error Scoring System (LESS). Female cadets were more likely to land with shallow sagittal flexion, wide stance width, and more pronounced knee flexion. Male cadets were more likely to exhibit a heel-strike or asymmetric foot-strike and to land with toe out. Lower extremity muscle strength, Q-angle, and navicular drop do not significantly predict landing movement pattern in male or female cadets. PMID:21132103
Dill, Karli E.; Begalle, Rebecca L.; Frank, Barnett S.; Zinder, Steven M.; Padua, Darin A.
2014-01-01
Context: Ankle-dorsiflexion (DF) range of motion (ROM) may influence movement variables that are known to affect anterior cruciate ligament loading, such as knee valgus and knee flexion. To our knowledge, researchers have not studied individuals with limited or normal ankle DF-ROM to investigate the relationship between those factors and the lower extremity movement patterns associated with anterior cruciate ligament injury. Objective: To determine, using 2 different measurement techniques, whether knee- and ankle-joint kinematics differ between participants with limited and normal ankle DF-ROM. Design: Cross-sectional study. Setting: Sports medicine research laboratory. Patients or Other Participants: Forty physically active adults (20 with limited ankle DF-ROM, 20 with normal ankle DF-ROM). Main Outcome Measure(s): Ankle DF-ROM was assessed using 2 techniques: (1) nonweight-bearing ankle DF-ROM with the knee straight, and (2) weight-bearing lunge (WBL). Knee flexion, knee valgus-varus, knee internal-external rotation, and ankle DF displacements were assessed during the overhead-squat, single-legged squat, and jump-landing tasks. Separate 1-way analyses of variance were performed to determine whether differences in knee- and ankle-joint kinematics existed between the normal and limited groups for each assessment. Results: We observed no differences between the normal and limited groups when classifying groups based on nonweight-bearing passive-ankle DF-ROM. However, individuals with greater ankle DF-ROM during the WBL displayed greater knee-flexion and ankle-DF displacement and peak knee flexion during the overhead-squat and single-legged squat tasks. In addition, those individuals also demonstrated greater knee-varus displacement during the single-legged squat. Conclusions: Greater ankle DF-ROM assessed during the WBL was associated with greater knee-flexion and ankle-DF displacement during both squatting tasks as well as greater knee-varus displacement during the single-legged squat. Assessment of ankle DF-ROM using the WBL provided important insight into compensatory movement patterns during squatting, whereas nonweight-bearing passive ankle DF-ROM did not. Improving ankle DF-ROM during the WBL may be an important intervention for altering high-risk movement patterns commonly associated with noncontact anterior cruciate ligament injury. PMID:25144599
Dill, Karli E; Begalle, Rebecca L; Frank, Barnett S; Zinder, Steven M; Padua, Darin A
2014-01-01
Ankle-dorsiflexion (DF) range of motion (ROM) may influence movement variables that are known to affect anterior cruciate ligament loading, such as knee valgus and knee flexion. To our knowledge, researchers have not studied individuals with limited or normal ankle DF-ROM to investigate the relationship between those factors and the lower extremity movement patterns associated with anterior cruciate ligament injury. To determine, using 2 different measurement techniques, whether knee- and ankle-joint kinematics differ between participants with limited and normal ankle DF-ROM. Cross-sectional study. Sports medicine research laboratory. Forty physically active adults (20 with limited ankle DF-ROM, 20 with normal ankle DF-ROM). Ankle DF-ROM was assessed using 2 techniques: (1) nonweight-bearing ankle DF-ROM with the knee straight, and (2) weight-bearing lunge (WBL). Knee flexion, knee valgus-varus, knee internal-external rotation, and ankle DF displacements were assessed during the overhead-squat, single-legged squat, and jump-landing tasks. Separate 1-way analyses of variance were performed to determine whether differences in knee- and ankle-joint kinematics existed between the normal and limited groups for each assessment. We observed no differences between the normal and limited groups when classifying groups based on nonweight-bearing passive-ankle DF-ROM. However, individuals with greater ankle DF-ROM during the WBL displayed greater knee-flexion and ankle-DF displacement and peak knee flexion during the overhead-squat and single-legged squat tasks. In addition, those individuals also demonstrated greater knee-varus displacement during the single-legged squat. Greater ankle DF-ROM assessed during the WBL was associated with greater knee-flexion and ankle-DF displacement during both squatting tasks as well as greater knee-varus displacement during the single-legged squat. Assessment of ankle DF-ROM using the WBL provided important insight into compensatory movement patterns during squatting, whereas nonweight-bearing passive ankle DF-ROM did not. Improving ankle DF-ROM during the WBL may be an important intervention for altering high-risk movement patterns commonly associated with noncontact anterior cruciate ligament injury.
Factors determining the level and changes in intra-articular pressure in the knee joint of the dog.
Nade, S; Newbold, P J
1983-01-01
Intra-articular pressure levels were determined for joint positions throughout the normal physiological range of movement of dogs' knee joints. Change in joint position resulted in change in intra-articular pressure. It was demonstrated that intra-articular pressure is highest with the joint in the fully flexed position. Minimum pressure was recorded at a position between 80 degrees and 120 degrees. Minimum pressures were usually subatmospheric. The rate of change of joint position affected intra-articular pressure. The relationship of intra-articular pressure and joint position before and after full flexion demonstrated a hysteresis effect; the pressures were lower than for the same joint position before flexion. Maintenance of the joint in the fully flexed position for increasing periods of time between repeated movement cycles resulted in a similar reduction, of constant magnitude, in pressure between joint positions before and after each period of flexion. However, there was also a progressive decrease in pressure for all joint angles over the total number of movement cycles. There is a contribution to intra-articular pressure of joint capsular compliance and fluid movement into and out of the joint (both of which are time-dependent). The recording of intra-articular pressure in conscious, upright dogs revealed similar pressure levels to those measured in anaesthetized supine dogs. The major determinants of intra-articular pressure in normal dog knee joints include joint size, synovial fluid volume, position of joint, peri-articular tissue and joint anatomy, membrane permeability, capsular compliance, and movement of fluid into and out of the joint. Images Fig. 1 PMID:6875957
Effect of hip and knee position on nerve conduction in the common fibular nerve.
Broadhurst, Peter Kaas; Robinson, Lawrence R
2017-09-01
The aim of this study was to measure the influence that hip and knee position have on routine fibular motor nerve conduction studies. Healthy subjects under age 40 were recruited (n = 24) to have fibular nerve conduction studies completed in various positions, using hip extension-knee extension as a control. A mean increase in conduction velocity of 2.5 m/s across the knee (P = 0.020) was seen during hip flexion compared with hip extension. A mean decrease in velocity of 1.6 m/s through the leg segment (P = 0.016) was seen during knee flexion compared with knee extension. This study shows that the optimal position of the leg during fibular nerve studies is with the hip in flexion and knee in extension, to more accurately reflect nerve length for velocity calculations. This may have implications for other peripheral nerves with respect to proximal joint position affecting calculated velocity. Muscle Nerve 56: 519-521, 2017. © 2017 Wiley Periodicals, Inc.
Gungor, Harun Resit; Kiter, Esat; Akkaya, Semih; Ok, Nusret; Yorukoglu, Cagdas
2015-01-01
Following total knee arthroplasty (TKA), the most frequent cause of extension deficit and limitation of range of motion in early postoperative period is related to improper tensioning of soft tissues and failure to balance extension and flexion gaps. If a cruciate retaining (CR) prosthesis is the planned implant, then attention should be given to balancing the posterior cruciate ligament (PCL), and any factor that alters this balance may also cause deterioration of knee balance in postoperative period. Here, we report on an unusual case referred from another hospital because of continuous pain and restriction of knee motion in early postoperative period following CR-designed TKA that was initially thought to be due to flexion-extension imbalance. However, during the revision procedure, extruded cement to the intercondylar notch was found to be both mechanically blocking terminal extension and limiting flexion by possible mechanism of irritation of the synovial nerve endings around the stretched anterior fibers of PCL during flexion. This case was successfully treated by removal of extruded cement from intercondylar notch to decompress PCL, polyethylene exchange, and secondary patellar resurfacing. PMID:26185697
A feedback inclusive neuromuscular training program alters frontal plane kinematics.
Greska, Eric K; Cortes, Nelson; Van Lunen, Bonnie L; Oñate, James A
2012-06-01
Anterior cruciate ligament (ACL) neuromuscular training programs have demonstrated beneficial effects in reducing ACL injuries, yet further evaluation of their effects on biomechanical measures across a sports team season is required to elucidate the specific factors that are modifiable. The purpose of this study was to evaluate the effects of a 10-week off-season neuromuscular training program on lower extremity kinematics. Twelve Division I female soccer players (age: 19.2 ± 0.8 years, height: 1.67 ± 0.1 m, weight: 60.2 ± 6.5 kg) performed unanticipated dynamic trials of a running stop-jump task pretraining and posttraining. Data collection was performed using an 8-camera Vicon system (Los Angeles, CA, USA) and 2 Bertec (Columbus, OH, USA) force plates. The 10-week training program consisted of resistance training 2 times per week and field training, consisting of plyometric, agility, and speed drills, 2 times per week. Repeated measures analyses of variance (ANOVAs) were used to assess the differences between pretraining and posttraining kinetics and kinematics of the hip, knee, and ankle at initial contact (IC), peak knee flexion (PKF), and peak stance. Repeated measures ANOVAs were also used to assess isometric strength differences pretraining and posttraining. The alpha level was set at 0.05 a priori. The training program demonstrated significant increases in left hip extension, left and right hip flexion, and right hip adduction isometric strength. At IC, knee abduction angle moved from an abducted to an adducted position (-1.48 ± 3.65° to 1.46 ± 3.86°, p = 0.007), and hip abduction angle increased (-6.05 ± 4.63° to -10.34 ± 6.83°, p = 0.007). Hip abduction angle at PKF increased (-2.23 ± 3.40° to 6.01 ± 3.82°, p = 0.002). The maximum knee extension moment achieved at peak stance increased from pretraining to posttraining (2.02 ± 0.32 to 2.38 ± 0.75 N·m·kg⁻¹, p = 0.027). The neuromuscular training program demonstrated a potential positive effect in altering mechanics that influence the risk of incurring an ACL injury.
Albano, Luigi
2017-01-01
Objective The purpose of this study is to introduce the application of Cox flexion distraction decompression as an innovative approach to treating knee pain and osteoarthritis. Methods Six months of clinical files from one chiropractic practice were retrospectively screened for patients who had been treated for knee pain. Twenty-five patients met the criteria for inclusion. The treatment provided was Cox flexion distraction decompression. Pre-treatment and post-treatment visual analog pain scales (VAS) were used to measure the results. In total, eight patients presented with acute knee pain (less than three months’ duration) and 18 patients presented with chronic knee pain (greater than three months) including two patients with continued knee pain after prosthetic replacement surgery. Results For all 25 patients, a change was observed in the mean VAS scores from 7.7 to 1.8. The mean number of treatments was 5.3 over an average of 3.0 weeks. Acute patient mean VAS scores dropped from 8.1 to 1.1 within 4.8 treatments over 2.4 weeks. Chronic patient mean VAS scores dropped from 7.5 to 2.2 within 5.4 treatments over 3.3 weeks. No adverse events were reported. Conclusion This study showed clinical improvement in patients with knee pain who were managed with Cox flexion distraction decompression applied to the knee. PMID:28928498
Eltoukhy, Moataz; Kelly, Adam; Kim, Chang-Young; Jun, Hyung-Pil; Campbell, Richard; Kuenze, Christopher
2016-01-01
Cost effective, quantifiable assessment of lower extremity movement represents potential improvement over standard tools for evaluation of injury risk. Ten healthy participants completed three trials of a drop jump, overhead squat, and single leg squat task. Peak hip and knee kinematics were assessed using an 8 camera BTS Smart 7000DX motion analysis system and the Microsoft Kinect® camera system. The agreement and consistency between both uncorrected and correct Kinect kinematic variables and the BTS camera system were assessed using interclass correlations coefficients. Peak sagittal plane kinematics measured using the Microsoft Kinect® camera system explained a significant amount of variance [Range(hip) = 43.5-62.8%; Range(knee) = 67.5-89.6%] in peak kinematics measured using the BTS camera system. Across tasks, peak knee flexion angle and peak hip flexion were found to be consistent and in agreement when the Microsoft Kinect® camera system was directly compared to the BTS camera system but these values were improved following application of a corrective factor. The Microsoft Kinect® may not be an appropriate surrogate for traditional motion analysis technology, but it may have potential applications as a real-time feedback tool in pathological or high injury risk populations.
Maderbacher, Günther; Matussek, Jan; Keshmiri, Armin; Greimel, Felix; Baier, Clemens; Grifka, Joachim; Maderbacher, Hermann
2018-02-17
Intramedullary rods are widely used to align the distal femoral cut in total knee arthroplasty. We hypothesised that both coronal (varus/valgus) and sagittal (extension/flexion) cutting plane are affected by rotational changes of intramedullary femoral alignment guides. Distal femoral cuts using intramedullary alignment rods were simulated by means of a computer-aided engineering software in 4°, 6°, 8°, 10°, and 12° of valgus in relation to the femoral anatomical axis and 4° extension, neutral, as well as 4°, 8°, and 12° of flexion in relation to the femoral mechanical axis. This reflects the different angles between anatomical and mechanical axis in coronal and sagittal planes. To assess the influence of rotation of the alignment guide on the effective distal femoral cutting plane, all combinations were simulated with the rod gradually aligned from 40° of external to 40° of internal rotation. Rotational changes of the distal femoral alignment guides affect both the coronal and sagittal cutting planes. When alignment rods are intruded neutrally with regards to sagittal alignment, external rotation causes flexion, while internal rotation causes extension of the sagittal cutting plane. Simultaneously the coronal effect (valgus) decreases resulting in an increased varus of the cutting plane. However, when alignment rods are intruded in extension or flexion partly contradictory effects are observed. Generally the effect increases with the degree of valgus preset, rotation and flexion. As incorrect rotation of intramedullary alignment guides for distal femoral cuts causes significant cutting errors, exact rotational alignment is crucial. Coronal cutting errors in the distal femoral plane might result in overall leg malalignment, asymmetric extension gaps and subsequent sagittal cutting errors.
Kim, Si-hyun; Kwon, Oh-yun; Park, Kyue-nam; Kim, Moon-Hwan
2013-12-01
The aim of this study was to compare the activity of the erector spinae (ES) and hamstring muscles and the amount and onset of lumbar motion during standing knee flexion between individuals with and without lumbar extension rotation syndrome. Sixteen subjects with lumbar extension rotation syndrome (10 males, 6 females) and 14 healthy subjects (8 males, 6 females) participated in this study. During the standing knee flexion, surface electromyography (EMG) was used to measure muscle activity, and surface EMG electrodes were attached to both the ES and hamstring (medial and lateral) muscles. A three-dimensional motion analysis system was used to measure kinematic data of the lumbar spine. An independent-t test was conducted for the statistical analysis. The group suffering from lumbar extension rotation syndrome exhibited asymmetric muscle activation of the ES and decreased hamstring activity. Additionally, the group with lumbar extension rotation syndrome showed greater and earlier lumbar extension and rotation during standing knee flexion compared to the control group. These data suggest that asymmetric ES muscle activation and a greater amount of and earlier lumbar motion in the sagittal and transverse plane during standing knee flexion may be an important factor contributing to low back pain. Copyright © 2013 Elsevier Ltd. All rights reserved.
Dynamic knee joint mechanics after anterior cruciate ligament reconstruction.
Clarke, Sarah B; Kenny, Ian C; Harrison, Andrew J
2015-01-01
There is scarcity of information on the long-term adaptations in lower limb biomechanics during game-specific movements after anterior cruciate ligament (ACL) reconstruction. Particularly, variables such as knee abduction moments and transverse plane knee motion have not been studied during a game-specific landing and cutting task after ACL reconstruction. The purpose of this study was to compare the hip and knee mechanics between the ACL-reconstructed (ACLr) group and a healthy control group. Thirty-eight reconstructed athletes (18 ACLr, 18 control) participated in the study. Three-dimensional hip, knee, and ankle angles were calculated during a maximal drop jump land from a 0.30-m box and unanticipated cutting task at 45°. During the landing phase, ACLr participants had increased hip flexion (P < 0.003) and transverse plane knee range of motion (P = 0.027). During the cutting phase, the ACLr participant's previously injured limb had increased internal knee abduction moment compared with that of the control group (P = 0.032). No significant differences were reported between the previously injured and contralateral uninjured limb. Previously injured participants demonstrated higher knee abduction moment and transverse plane range of motion when compared with those of control participants during a game-specific landing and cutting task.
Lura, Derek J; Wernke, Matthew W; Carey, Stephanie L; Kahle, Jason T; Miro, Rebecca M; Highsmith, M Jason
2017-10-01
This study was a randomized crossover of stair ambulation of Transfemoral Amputees (TFAs) using the Genium and C-Leg prosthetic knees. TFAs typically have difficulty ascending and descending stairs, limiting community mobility. The objective of this study was to determine the relative efficacy of the Genium and C-Leg prostheses for stair ascent and descent, and their absolute efficacy relative to non-amputees. Twenty TFAs, and five non-amputees participated in the study. TFAs were randomized to begin the study with the Genium or C-Leg prosthesis. Informed consent was obtained from all participants prior to data collection and the study was listed on clinicaltrials.gov (#NCT01473662). After fitting, accommodation, and training, participants were asked to demonstrate their preferred gait pattern for stair ascent and descent and a step-over-step pattern if able. TFAs then switched prosthetic legs and repeated fitting, accommodation, training, and testing. An eight camera Vicon optical motion analysis system, and two AMTI force plates were used to track and analyze the participants' gait patterns, knee flexion angles, knee moment normalized by body weight, and swing time. For stair descent, no significant differences were found between prostheses. For stair ascent, Genium use resulted in: increased ability to use a step-over-step gait pattern (p=0.03), increased prosthetic side peak knee flexion (p<0.01), and increased swing duration (p<0.01). Changes in contralateral side outcomes and in knee moment were not significant. Overall the Genium knee decreased deficiency in gait patterns for stair ascent relative to the C-Leg, by enabling gait patterns that more closely resembled non-amputees. Copyright © 2017 Elsevier B.V. All rights reserved.