Sample records for knee impact test

  1. 49 CFR 572.166 - Knees and knee impact test procedure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Knees and knee impact test procedure. 572.166... Hybrid III Six-Year-Old Weighted Child Test Dummy § 572.166 Knees and knee impact test procedure. The knee assembly is assembled and tested as specified in 49 CFR 572.126 (Subpart N). ...

  2. Impact response and biomechanical analysis of the knee-thigh-hip complex in frontal impacts with a full human body finite element model.

    PubMed

    Ruan, Jesse S; El-Jawahri, Raed; Barbat, Saeed; Rouhana, Stephen W; Prasad, Priya

    2008-11-01

    Changes in vehicle safety design technology and the increasing use of seat-belts and airbag restraint systems have gradually changed the relative proportion of lower extremity injuries. These changes in real world injuries have renewed interest and the need of further investigation into occupant injury mechanisms and biomechanical impact responses of the knee-thigh-hip complex during frontal impacts. This study uses a detailed finite element model of the human body to simulate occupant knee impacts experienced in frontal crashes. The human body model includes detailed anatomical features of the head, neck, shoulder, chest, thoracic and lumbar spine, abdomen, pelvis, and lower and upper extremities. The material properties used in the model for each anatomic part of the human body were obtained from test data reported in the literature. The human body model used in the current study has been previously validated in frontal and side impacts. It was further validated with cadaver knee-thigh-hip impact tests in the current study. The effects of impactor configuration and flexion angle of the knee on biomechanical impact responses of the knee-thigh-hip complex were studied using the validated human body finite element model. This study showed that the knee flexion angle and the impact direction and shape of the impactors affected the injury outcomes of the knee-thigh-hip complex significantly. The 60 degrees flexed knee impact showed the least impact force, knee pressure, femoral von Mises stress, and pelvic von Mises stress but largest relative displacements of the Posterior Cruciate Ligament (PCL) and Anterior Cruciate Ligament (ACL). The 90 degrees flexed knee impact resulted in a higher impact force, knee pressure, femoral von Mises stress, and pelvic von Mises stress; but smaller PCL and ACL displacements. Stress distributions of the patella, femur, and pelvis were also given for all the simulated conditions.

  3. 49 CFR 572.176 - Knees and knee impact test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... procedure in subsection (c) of this section: (1) The peak resistance force as measured with the test probe.... (3) Align the test probe so that throughout its stroke and at contact with the knee it is within 2... contact between the impactor and the knee. (5) The test probe velocity at the time of contact shall be 2.1...

  4. 49 CFR 572.176 - Knees and knee impact test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... procedure in subsection (c) of this section: (1) The peak resistance force as measured with the test probe.... (3) Align the test probe so that throughout its stroke and at contact with the knee it is within 2... contact between the impactor and the knee. (5) The test probe velocity at the time of contact shall be 2.1...

  5. 49 CFR 572.176 - Knees and knee impact test procedure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... procedure in subsection (c) of this section: (1) The peak resistance force as measured with the test probe.... (3) Align the test probe so that throughout its stroke and at contact with the knee it is within 2... contact between the impactor and the knee. (5) The test probe velocity at the time of contact shall be 2.1...

  6. Injury risk curves for the skeletal knee-thigh-hip complex for knee-impact loading.

    PubMed

    Rupp, Jonathan D; Flannagan, Carol A C; Kuppa, Shashi M

    2010-01-01

    Injury risk curves for the skeletal knee-thigh-hip (KTH) relate peak force applied to the anterior aspect of the flexed knee, the primary source of KTH injury in frontal motor-vehicle crashes, to the probability of skeletal KTH injury. Previous KTH injury risk curves have been developed from analyses of peak knee-impact force data from studies where knees of whole cadavers were impacted. However, these risk curves either neglect the effects of occupant gender, stature, and mass on KTH fracture force, or account for them using scaling factors derived from dimensional analysis without empirical support. A large amount of experimental data on the knee-impact forces associated with KTH fracture are now available, making it possible to estimate the effects of subject characteristics on skeletal KTH injury risk by statistically analyzing empirical data. Eleven studies were identified in the biomechanical literature in which the flexed knees of whole cadavers were impacted. From these, peak knee-impact force data and the associated subject characteristics were reanalyzed using survival analysis with a lognormal distribution. Results of this analysis indicate that the relationship between peak knee-impact force and the probability of KTH fracture is a function of age, total body mass, and whether the surface that loads the knee is rigid. Comparisons between injury risk curves for the midsize adult male and small adult female crash test dummies defined in previous studies and new risk curves for these sizes of occupants developed in this study suggest that previous injury risk curves generally overestimate the likelihood of KTH fracture at a given peak knee-impact force. Future work should focus on defining the relationships between impact force at the human knee and peak axial compressive forces measured by load cells in the crash test dummy KTH complex so that these new risk curves can be used with ATDs.

  7. Coupling lateral bending and shearing mechanisms to define knee injury criteria for pedestrian safety.

    PubMed

    Mo, Fuhao; Masson, Catherine; Cesari, Dominique; Arnoux, Pierre Jean

    2013-01-01

    In car-pedestrian accidents, lateral bending and shearing kinematics have been identified as principal injury mechanisms causing permanent disabilities and impairments to the knee joint. Regarding the combined lateral bending and shearing contributions of knee joint kinematics, developing a coupled knee injury criterion is necessary for improving vehicle countermeasures to mitigate pedestrian knee injuries. The advantages of both experimental tests and finite element (FE) simulations were combined to determine the reliable injury tolerances of the knee joint. First, 7 isolated lower limb tests from postmortem human subjects (PMHS) were reported, with dynamic loading at a velocity of 20 km/h. With the intention of replicating relevant injury mechanisms of vehicle-pedestrian impacts, the experimental tests were categorized into 3 groups by the impact locations on the tibia: the distal end to prioritize pure bending, the middle diaphysis to have combined bending and shearing effects, and the proximal end to acquire pure shearing. Then, the corresponding FE model was employed to provide an additional way to determine exact injury occurrences and develop a robust knee injury criterion by the variation in both the lateral bending and shearing contributions through a sensitivity analysis of impact locations. Considering the experimental test results and the subsequent sensitivity analysis of FE simulations, both the tolerances and patterns of knee joint injuries were determined to be influenced by impact locations due to various combined contributions of lateral bending and shearing. Both medial collateral ligament and cruciate ligament failures were noted as the onsets of knee injuries, namely, initial injuries. Finally, a new injury criterion categorized by initial injury patterns of knee joint was proposed by coupling lateral bending and shearing levels. The developed injury criterion correlated the combined joint kinematics to initial knee injuries based on subsegment tests and FE simulations conducted with a biofidelic lower limb model. This provides a valuable way of predicting the risk of knee injury associated with vehicle-pedestrian crashes and thereby represents a further step to promote the design of vehicle countermeasures for pedestrian safety.

  8. 49 CFR 572.136 - Knees and knee impact test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... as measured with the test probe-mounted accelerometer must be not less than 3450 N (776 lbf) and not... tibia may contact any exterior surface. (3) Align the test probe so that throughout its stroke and at... movement at the time of initial contact between the impactor and the knee. (5) The test probe velocity at...

  9. 49 CFR 572.136 - Knees and knee impact test procedure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... as measured with the test probe-mounted accelerometer must be not less than 3450 N (776 lbf) and not... tibia may contact any exterior surface. (3) Align the test probe so that throughout its stroke and at... movement at the time of initial contact between the impactor and the knee. (5) The test probe velocity at...

  10. 49 CFR 572.136 - Knees and knee impact test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... as measured with the test probe-mounted accelerometer must be not less than 3450 N (776 lbf) and not... tibia may contact any exterior surface. (3) Align the test probe so that throughout its stroke and at... movement at the time of initial contact between the impactor and the knee. (5) The test probe velocity at...

  11. 49 CFR 572.136 - Knees and knee impact test procedure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... as measured with the test probe-mounted accelerometer must be not less than 3450 N (776 lbf) and not... tibia may contact any exterior surface. (3) Align the test probe so that throughout its stroke and at... movement at the time of initial contact between the impactor and the knee. (5) The test probe velocity at...

  12. 49 CFR 572.136 - Knees and knee impact test procedure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... as measured with the test probe-mounted accelerometer must be not less than 3450 N (776 lbf) and not... tibia may contact any exterior surface. (3) Align the test probe so that throughout its stroke and at... movement at the time of initial contact between the impactor and the knee. (5) The test probe velocity at...

  13. Development of new injury risk curves for the knee/distal femur and the hip for use in frontal impact testing.

    DOT National Transportation Integrated Search

    2009-06-01

    This report describes how new injury risk curves for the knee/distal femur and the hip were : developed through reanalyses of existing peak knee impact force data. New hip injury risk : curves were developed using survival analysis with a lognormal d...

  14. 49 CFR 572.126 - Knees and knee impact test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... procedure in section 572.127(c), the peak resistance force as measured with the test probe mounted... exterior surface. (3) Align the test probe so that throughout its stroke and at contact with the knee it is... probe velocity at the time of contact shall be 2.1 ±0.03 m/s (6.9 # 0.1 ft/s). (6) No suspension...

  15. 49 CFR 572.126 - Knees and knee impact test procedure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... procedure in section 572.127(c), the peak resistance force as measured with the test probe mounted... exterior surface. (3) Align the test probe so that throughout its stroke and at contact with the knee it is... probe velocity at the time of contact shall be 2.1 ±0.03 m/s (6.9 # 0.1 ft/s). (6) No suspension...

  16. 49 CFR 572.126 - Knees and knee impact test procedure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... procedure in section 572.127(c), the peak resistance force as measured with the test probe mounted... exterior surface. (3) Align the test probe so that throughout its stroke and at contact with the knee it is... probe velocity at the time of contact shall be 2.1 ±0.03 m/s (6.9 # 0.1 ft/s). (6) No suspension...

  17. 49 CFR 572.126 - Knees and knee impact test procedure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... procedure in section 572.127(c), the peak resistance force as measured with the test probe mounted... exterior surface. (3) Align the test probe so that throughout its stroke and at contact with the knee it is... probe velocity at the time of contact shall be 2.1 ±0.03 m/s (6.9 # 0.1 ft/s). (6) No suspension...

  18. 49 CFR 572.126 - Knees and knee impact test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... procedure in section 572.127(c), the peak resistance force as measured with the test probe mounted... exterior surface. (3) Align the test probe so that throughout its stroke and at contact with the knee it is... probe velocity at the time of contact shall be 2.1 ±0.03 m/s (6.9 # 0.1 ft/s). (6) No suspension...

  19. 49 CFR 572.10 - Limbs.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... planes parallel to its midsagittal plane (knee pivot centerline perpendicular to the midsagittal plane...) Impact the knee with the test probe moving horizontally and parallel to the midsagittal plane at the...

  20. Predicting the effects of muscle activation on knee, thigh, and hip injuries in frontal crashes using a finite-element model with muscle forces from subject testing and musculoskeletal modeling.

    PubMed

    Chang, Chia-Yuan; Rupp, Jonathan D; Reed, Matthew P; Hughes, Richard E; Schneider, Lawrence W

    2009-11-01

    In a previous study, the authors reported on the development of a finite-element model of the midsize male pelvis and lower extremities with lower-extremity musculature that was validated using PMHS knee-impact response data. Knee-impact simulations with this model were performed using forces from four muscles in the lower extremities associated with two-foot bracing reported in the literature to provide preliminary estimates of the effects of lower-extremity muscle activation on knee-thigh-hip injury potential in frontal impacts. The current study addresses a major limitation of these preliminary simulations by using the AnyBody three-dimensional musculoskeletal model to estimate muscle forces produced in 35 muscles in each lower extremity during emergency one-foot braking. To check the predictions of the AnyBody Model, activation levels of twelve major muscles in the hip and lower extremities were measured using surface EMG electrodes on 12 midsize-male subjects performing simulated maximum and 50% of maximum braking in a laboratory seating buck. Comparisons between test results and the predictions of the AnyBody Model when it was used to simulate these same braking tests suggest that the AnyBody model appropriately predicts agonistic muscle activations but under predicts antagonistic muscle activations. Simulations of knee-to-knee-bolster impacts were performed by impacting the knees of the lower-extremity finite element model with and without the muscle forces predicted by the validated AnyBody Model. Results of these simulations confirm previous findings that muscle tension increases knee-impact force by increasing the effective mass of the KTH complex due to tighter coupling of muscle mass to bone. They also indicate that muscle activation preferentially couples mass distal to the hip, thereby accentuating the decrease in femur force from the knee to the hip. However, the reduction in force transmitted from the knee to the hip is offset by the increased force at the knee and by increased compressive forces at the hip due to activation of lower-extremity muscles. As a result, approximately 45% to 60% and 50% to 65% of the force applied to the knee is applied to the hip in the simulations without and with muscle tension, respectively. The simulation results suggest that lower-extremity muscle tension has little effect on the risk of hip injuries, but it increases the bending moments in the femoral shaft, thereby increasing the risk of femoral shaft fractures by 20%-40%. However, these findings may be affected by the inability of the AnyBody Model to appropriately predict antagonistic muscle forces.

  1. Posterior tibial slope impacts intraoperatively measured mid-flexion anteroposterior kinematics during cruciate-retaining total knee arthroplasty.

    PubMed

    Dai, Yifei; Cross, Michael B; Angibaud, Laurent D; Hamad, Cyril; Jung, Amaury; Jenny, Jean-Yves

    2018-02-23

    Posterior tibial slope (PTS) for cruciate-retaining (CR) total knee arthroplasty (TKA) is usually pre-determined by the surgeon. Limited information is available comparing different choices of PTS on the kinematics of the CR TKA, independent of the balancing of the extension gap. This study hypothesized that with the same balanced extension gap, the choice of PTS significantly impacts the intraoperatively measured kinematics of CR TKA. Navigated CR TKAs were performed on seven fresh-frozen cadavers with healthy knees and intact posterior cruciate ligament (PCL). A custom designed tibial baseplate was implanted to allow in situ modification of the PTS, which altered the flexion gap but maintained the extension gap. Knee kinematics were measured by performing passive range of motion (ROM) tests from full extension to 120° of flexion on the intact knee and CR TKAs with four different PTSs (1°, 4°, 7°, and 10°). The measured kinematics were compared across test conditions to assess the impact of PTS. With a consistent extension gap, the change of PTS had significant impact on the anteroposterior (AP) kinematics of the CR TKA knees in mid-flexion range (45°-90°), but not so much for the high-flexion range (90°-120°). No considerable impacts were found on internal/external (I/E) rotation and hip-knee-ankle (HKA) angle. However, the findings on the individual basis suggested the impact of PTS on I/E rotation and HKA angle may be patient-specific. The data suggested that the choice of PTS had the greatest impact on the mid-flexion AP translation among the intraoperatively measured kinematics. This impact may be considered while making surgical decisions in the context of AP kinematics. When using a tibial component designed with "center" pivoting PTS, a surgeon may be able to fine tune the PTS to achieve proper mid-flexion AP stability.

  2. Joint laxity and the relationship between muscle strength and functional ability in patients with osteoarthritis of the knee.

    PubMed

    van der Esch, M; Steultjens, M; Knol, D L; Dinant, H; Dekker, J

    2006-12-15

    To establish the impact of knee joint laxity on the relationship between muscle strength and functional ability in osteoarthritis (OA) of the knee. A cross-sectional study of 86 patients with OA of the knee was conducted. Tests were performed to determine varus-valgus laxity, muscle strength, and functional ability. Laxity was assessed using a device that measures the angular deviation of the knee in the frontal plane. Muscle strength was measured using a computer-driven isokinetic dynamometer. Functional ability was assessed by observation (100-meter walking test) and self report (Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC]). Regression analyses were performed to assess the impact of joint laxity on the relationship between muscle strength and functional ability. In regression analyses, the interaction between muscle strength and joint laxity contributed to the variance in both walking time (P = 0.002) and WOMAC score (P = 0.080). The slope of the regression lines indicated that the relationship between muscle strength and functional ability (walking time, WOMAC) was stronger in patients with high knee joint laxity. Patients with knee OA and high knee joint laxity show a stronger relationship between muscle strength and functional ability than patients with OA and low knee joint laxity. Patients with OA, high knee joint laxity, and low muscle strength are most at risk of being disabled.

  3. The Effect of Upper Body Mass and Initial Knee Flexion on the Injury Outcome of Post Mortem Human Subject Pedestrian Isolated Legs.

    PubMed

    Petit, Philippe; Trosseille, Xavier; Dufaure, Nicolas; Dubois, Denis; Potier, Pascal; Vallancien, Guy

    2014-11-01

    In the ECE 127 Regulation on pedestrian leg protection, as well as in the Euro NCAP test protocol, a legform impactor hits the vehicle at the speed of 40 kph. In these tests, the knee is fully extended and the leg is not coupled to the upper body. However, the typical configuration of a pedestrian impact differs since the knee is flexed during most of the gait cycle and the hip joint applies an unknown force to the femur. This study aimed at investigating the influence of the inertia of the upper body (modelled using an upper body mass fixed at the proximal end of the femur) and the initial knee flexion angle on the lower limb injury outcome. In total, 18 tests were conducted on 18 legs from 9 Post Mortem Human Subjects (PMHS). The principle of these tests was to impact the leg at 40 kph using a sled equipped with 3 crushing steel tubes, the stiffness of which were representative of the front face of a European sedan (bonnet leading edge, bumper and spoiler). The mass of the equipped sled was 74.5 kg. The test matrix was designed to perform 4 tests in 4 configurations combining two upper body masses (either 0 or 3 kg) and two knee angles (0 or 20 degrees) at 40 kph (11 m/s) plus 2 tests at 9 m/s. Autopsies were performed on the lower limbs and an injury assessment was established. The findings of this study were first that the increase of the upper body mass resulted in more severe injuries, second that an initial flexion of the knee, corresponding to its natural position during the gait cycle, decreased the severity of the injuries, and third that based on the injury outcome, a test conducted with no upper body mass and the knee fully extended was as severe as a test conducted with a 3 kg upper body mass and an initial knee flexion of 20°.

  4. Knee stiffness and viscosity: New implementation and perspectives in prosthesis development

    PubMed Central

    Bohinc, Klemen; Vantur, Nejc; Torkar, Drago; Lampe, Tomaž; Hribernik, Marija; Jakovljević, Miroljub

    2017-01-01

    The pendulum test is a method applied to measure passive resistance of the knee. A new and simple pendulum test with instrumentation based on infrared camera was used to evaluate knee stiffness and viscosity on a female human cadaver. The stiffness and viscosity were calculated based on the kinetic data. During the measurements, the periarticular and intraarticular soft tissue of the knee was gradually removed to determine the stiffness and viscosity as a function of the tissue removal rate. The measurements showed that the removal of tissue around the joint reduces the damping of leg oscillation, and therefore decreases the stiffness and viscosity. The contribution to knee joint damping was 10% for the skin, 20% for ligaments, and 40% for muscles and tendons. Tissue removal has a very large impact on the knee stiffness and viscosity. PMID:28422623

  5. Knee stiffness and viscosity: New implementation and perspectives in prosthesis development.

    PubMed

    Bohinc, Klemen; Vantur, Nejc; Torkar, Drago; Lampe, Tomaž; Hribernik, Marija; Jakovljević, Miroljub

    2017-05-20

    The pendulum test is a method applied to measure passive resistance of the knee. A new and simple pendulum test with instrumentation based on infrared camera was used to evaluate knee stiffness and viscosity on a female human cadaver. The stiffness and viscosity were calculated based on the kinetic data. During the measurements, the periarticular and intraarticular soft tissue of the knee was gradually removed to determine the stiffness and viscosity as a function of the tissue removal rate. The measurements showed that the removal of tissue around the joint reduces the damping of leg oscillation, and therefore decreases the stiffness and viscosity. The contribution to knee joint damping was 10% for the skin, 20% for ligaments, and 40% for muscles and tendons. Tissue removal has a very large impact on the knee stiffness and viscosity.

  6. A 10-Year Prospective Trial of a Patient Management Algorithm and Screening Examination for Highly Active Individuals with ACL Injury. Part II: Determinants of Dynamic Knee Stability

    PubMed Central

    Hurd, Wendy J.; Axe, Michael J.; Snyder-Mackler, Lynn

    2010-01-01

    Objectives To clarify the determinants of dynamic knee stability early after anterior cruciate ligament (ACL) injury. Materials and Methods 345 consecutive patients who were regular participants in IKDC level I/II sports before injury and had an acute isolated ACL injury from the practice of a single orthopaedic surgeon underwent a screening examination including clinical measures, knee laxity, quadriceps strength, hop testing, and patient self-reported knee function an average of 6 weeks after injury when impairments were resolved. Independent t-tests were performed to evaluate differences in quadriceps strength and anterior knee laxity between potential copers and noncopers. Hierarchical regression was performed to determine the influence of quadriceps strength, pre-injury activity level, and anterior knee laxity on hop test performance, as well as the influence of timed hop, cross-over hop, quadriceps strength, pre-injury activity level, and anterior knee laxity on self-assessed global function. Results Neither anterior knee laxity nor quadriceps strength differed between potential copers and non-copers. Quadriceps strength influenced hop test performance more significantly than pre-injury activity level or anterior knee laxity, but the variance accounted for by quadriceps strength was low (Range: 4-8%). Timed hop performance was the only variable that impacted self-assessed global function. Conclusions Traditional surgical decision making based on passive anterior knee laxity and pre-injury activity level is not supported by the results, as neither are good predictors of dynamic knee stability. Clinical tests that capture neuromuscular adaptations, including the timed hop test, may be useful in predicting function and guiding individualized patient management after ACL injury. PMID:17932399

  7. Long-term clinical evaluation of the automatic stance-phase lock-controlled prosthetic knee joint in young adults with unilateral above-knee amputation.

    PubMed

    Andrysek, Jan; Wright, F Virginia; Rotter, Karin; Garcia, Daniela; Valdebenito, Rebeca; Mitchell, Carlos Alvarez; Rozbaczylo, Claudio; Cubillos, Rafael

    2017-05-01

    The purpose of this study was to clinically evaluate the automatic stance-phase lock (ASPL) knee mechanism against participants' existing weight-activated braking (WAB) prosthetic knee joint. This prospective crossover study involved 10 young adults with an above-knee amputation. Primary measurements consisted of tests of walking speeds and capacity. Heart rate was measured during the six-minute walk test and the Physiological Cost Index (PCI) which was calculated from heart rate estimated energy expenditure. Activity was measured with a pedometer. User function and quality of life were assessed using the Lower Limb Function Questionnaire (LLFQ) and Prosthetic Evaluation Questionnaire (PEQ). Long-term follow-up over 12 months were completed. Walking speeds were the same for WAB and APSL knees. Energy expenditure (PCI) was lower for the ASPL knees (p = 0.007). Step counts were the same for both knees, and questionnaires indicated ASPL knee preference attributed primarily to knee stability and improved walking, while limitations included terminal impact noise. Nine of 10 participants chose to keep using the ASPL knee as part of the long-term follow-up. Potential benefits of the ASPL knee were identified in this study by functional measures, questionnaires and user feedback, but not changes in activity or the PEQ.

  8. Poor WOMAC scores in contralateral knee negatively impact TKA outcomes: data from the osteoarthritis initiative.

    PubMed

    Kahn, Timothy L; Soheili, Aydin C; Schwarzkopf, Ran

    2014-08-01

    While total knee arthroplasty (TKA) has been shown to have excellent outcomes, a significant proportion of patients experience relatively poor post-operative function. In this study, we test the hypothesis that the level of osteoarthritic symptoms in the contralateral knee at the time of TKA is associated with poorer post-operative outcomes in the operated knee. Using longitudinal cohort data from the Osteoarthritis Initiative (OAI), we included 171 patients who received a unilateral TKA. We compared pre-operative Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores in the contralateral knee to post-operative WOMAC scores in the index knee. Pre-operative contralateral knee WOMAC scores were associated with post-operative index knee WOMAC Total scores, indicating that the health of the pre-operative contralateral knee is a significant factor in TKA outcomes. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. 49 CFR 572.10 - Limbs.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... of the forward edge of the seat. (3) Align the test probe specified in § 572.11(a) so that at impact...) Impact the knee with the test probe moving horizontally and parallel to the midsagittal plane at the specified velocity. (5) Guide the probe during impact so that it moves with no significant lateral, vertical...

  10. 49 CFR 572.10 - Limbs.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... of the forward edge of the seat. (3) Align the test probe specified in § 572.11(a) so that at impact...) Impact the knee with the test probe moving horizontally and parallel to the midsagittal plane at the specified velocity. (5) Guide the probe during impact so that it moves with no significant lateral, vertical...

  11. 49 CFR 572.10 - Limbs.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... of the forward edge of the seat. (3) Align the test probe specified in § 572.11(a) so that at impact...) Impact the knee with the test probe moving horizontally and parallel to the midsagittal plane at the specified velocity. (5) Guide the probe during impact so that it moves with no significant lateral, vertical...

  12. 49 CFR 572.10 - Limbs.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... of the forward edge of the seat. (3) Align the test probe specified in § 572.11(a) so that at impact...) Impact the knee with the test probe moving horizontally and parallel to the midsagittal plane at the specified velocity. (5) Guide the probe during impact so that it moves with no significant lateral, vertical...

  13. Numerical Investigations of Interactions between the Knee-Thigh-Hip Complex with Vehicle Interior Structures.

    PubMed

    Kim, Yong Sun; Choi, Hyeong Ho; Cho, Young Nam; Park, Yong Jae; Lee, Jong B; Yang, King H; King, Albert I

    2005-11-01

    Although biomechanical studies on the knee-thigh-hip (KTH) complex have been extensive, interactions between the KTH and various vehicular interior design parameters in frontal automotive crashes for newer models have not been reported in the open literature to the best of our knowledge. A 3D finite element (FE) model of a 50(th) percentile male KTH complex, which includes explicit representations of the iliac wing, acetabulum, pubic rami, sacrum, articular cartilage, femoral head, femoral neck, femoral condyles, patella, and patella tendon, has been developed to simulate injuries such as fracture of the patella, femoral neck, acetabulum, and pubic rami of the KTH complex. Model results compared favorably against regional component test data including a three-point bending test of the femur, axial loading of the isolated knee-patella, axial loading of the KTH complex, axial loading of the femoral head, and lateral loading of the isolated pelvis. The model was further integrated into a Wayne State University upper torso model and validated against data obtained from whole body sled tests. The model was validated against these experimental data over a range of impact speeds, impactor masses and boundary conditions. Using Design Of Experiment (DOE) methods based on Taguchi's approach and the developed FE model of the whole body, including the KTH complex, eight vehicular interior design parameters, namely the load limiter force, seat belt elongation, pretensioner inlet amount, knee-knee bolster distance, knee bolster angle, knee bolster stiffness, toe board angle and impact speed, each with either two or three design levels, were simulated to predict their respective effects on the potential of KTH injury in frontal impacts. Simulation results proposed best design levels for vehicular interior design parameters to reduce the injury potential of the KTH complex due to frontal automotive crashes. This study is limited by the fact that prediction of bony fracture was based on an element elimination method available in the LS-DYNA code. No validation study was conducted to determine if this method is suitable when simulating fractures of biological tissues. More work is still needed to further validate the FE model of the KTH complex to increase its reliability in the assessment of various impact loading conditions associated with vehicular crash scenarios.

  14. 49 CFR 572.76 - Limbs assembly and test procedure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    .... (3) Align the test probe specified in § 572.77(a) with the longitudinal center line of the femur force gauge, so that at impact, the probe's longitudinal center line coincides with the sensor's longitudinal center line within ±2 degrees. (4) Impact the knee with the test probe moving horizontally and...

  15. 49 CFR 572.76 - Limbs assembly and test procedure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    .... (3) Align the test probe specified in § 572.77(a) with the longitudinal center line of the femur force gauge, so that at impact, the probe's longitudinal center line coincides with the sensor's longitudinal center line within ±2 degrees. (4) Impact the knee with the test probe moving horizontally and...

  16. 49 CFR 572.76 - Limbs assembly and test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    .... (3) Align the test probe specified in § 572.77(a) with the longitudinal center line of the femur force gauge, so that at impact, the probe's longitudinal center line coincides with the sensor's longitudinal center line within ±2 degrees. (4) Impact the knee with the test probe moving horizontally and...

  17. 49 CFR 572.76 - Limbs assembly and test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .... (3) Align the test probe specified in § 572.77(a) with the longitudinal center line of the femur force gauge, so that at impact, the probe's longitudinal center line coincides with the sensor's longitudinal center line within ±2 degrees. (4) Impact the knee with the test probe moving horizontally and...

  18. A Progressive Damage Model for Predicting Permanent Indentation and Impact Damage in Composite Laminates

    NASA Astrophysics Data System (ADS)

    Ji, Zhaojie; Guan, Zhidong; Li, Zengshan

    2017-10-01

    In this paper, a progressive damage model was established on the basis of ABAQUS software for predicting permanent indentation and impact damage in composite laminates. Intralaminar and interlaminar damage was modelled based on the continuum damage mechanics (CDM) in the finite element model. For the verification of the model, low-velocity impact tests of quasi-isotropic laminates with material system of T300/5228A were conducted. Permanent indentation and impact damage of the laminates were simulated and the numerical results agree well with the experiments. It can be concluded that an obvious knee point can be identified on the curve of the indentation depth versus impact energy. Matrix cracking and delamination develops rapidly with the increasing impact energy, while considerable amount of fiber breakage only occurs when the impact energy exceeds the energy corresponding to the knee point. Predicted indentation depth after the knee point is very sensitive to the parameter μ which is proposed in this paper, and the acceptable value of this parameter is in range from 0.9 to 1.0.

  19. Impact of exercise on the functional capacity and pain of patients with knee osteoarthritis: a randomized clinical trial.

    PubMed

    Oliveira, Aline Mizusaki Imoto de; Peccin, Maria Stella; Silva, Kelson Nonato Gomes da; Teixeira, Lucas Emmanuel Pedro de Paiva; Trevisani, Virgínia Fernandes Moça

    2012-12-01

    Muscle weakness, especially of the quadriceps muscle, is one of the major musculoskeletal effects of knee osteoarthritis. Exercises are considered one of the main interventions in the conservative treatment of those patients. To assess the effectiveness of quadriceps strengthening exercises on functional capacity and symptoms related of knee osteoarthritis by use of the Timed Up and Go test (TUG), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the Lequesne Index. One hundred patients were randomized into two groups: 1) Exercise Group (n = 50), which included stationary bicycle, hamstrings stretching, and quadriceps strengthening; 2) Instruction Group (n = 50), which received a manual with information about knee osteoarthritis and instructions on how to deal with knee symptoms in daily activities. The manual did not include exercise instructions. The Exercise Group showed statistically significant improvement regarding the TUG test, the WOMAC aspects of pain, function, and stiffness, and the Lequesne Index, as compared with the Instruction Group. Quadriceps strengthening exercises for eight weeks are effective to improve pain, function, and stiffness in patients with knee osteoarthritis.

  20. Eliminating impingement optimizes patellar biomechanics in high knee flexion.

    PubMed

    Tang, Qi-heng; Zhou, Yi-xin; Tang, Jing; Shao, Hong-yi; Wang, Guang-zhi

    2010-08-01

    We investigated the impact of eliminating the impingement between extensor mechanism and tibial insert on patellar tracking and patellar ligament tension in high knee flexion. Six cadaveric specimens were tested on an Oxford-type testing rig. The Genesis II knee system was implanted into each specimen knee with the traditional tibial insert and high-flex insert successively. Compared to traditional insert, the high-flex insert was characterized with a chambered anterior post and a chambered anterior lip which eliminates patella-post and patellar ligament-anterior lip impingements. The patella was tracked with an NDI Optotrak Certus system. The patellar ligament tension was measured using a NKB S-type tension transducer. There was a decrease of resultant patellar translation relative to the femur with statistically significant (P<0.05) at 90 degrees to 150 degrees of knee flexion and a decrease of patellar ligament tension with statistical significance (P<0.05) at 100 degrees, 120 degrees, 130 degrees, and 140 degrees of flexion using high-flex insert compared to traditional insert. Eliminating the impingement between extensor mechanism and implant in high knee flexion altered patellar tracking and reduced patellar ligament tension, which would facilitate high knee flexion.

  1. Injury tolerance and moment response of the knee joint to combined valgus bending and shear loading.

    PubMed

    Bose, Dipan; Bhalla, Kavi S; Untaroiu, Costin D; Ivarsson, B Johan; Crandall, Jeff R; Hurwitz, Shepard

    2008-06-01

    Valgus bending and shearing of the knee have been identified as primary mechanisms of injuries in a lateral loading environment applicable to pedestrian-car collisions. Previous studies have reported on the structural response of the knee joint to pure valgus bending and lateral shearing, as well as the estimated injury thresholds for the knee bending angle and shear displacement based on experimental tests. However, epidemiological studies indicate that most knee injuries are due to the combined effects of bending and shear loading. Therefore, characterization of knee stiffness for combined loading and the associated injury tolerances is necessary for developing vehicle countermeasures to mitigate pedestrian injuries. Isolated knee joint specimens (n=40) from postmortem human subjects were tested in valgus bending at a loading rate representative of a pedestrian-car impact. The effect of lateral shear force combined with the bending moment on the stiffness response and the injury tolerances of the knee was concurrently evaluated. In addition to the knee moment-angle response, the bending angle and shear displacement corresponding to the first instance of primary ligament failure were determined in each test. The failure displacements were subsequently used to estimate an injury threshold function based on a simplified analytical model of the knee. The validity of the determined injury threshold function was subsequently verified using a finite element model. Post-test necropsy of the knees indicated medial collateral ligament injury consistent with the clinical injuries observed in pedestrian victims. The moment-angle response in valgus bending was determined at quasistatic and dynamic loading rates and compared to previously published test data. The peak bending moment values scaled to an average adult male showed no significant change with variation in the superimposed shear load. An injury threshold function for the knee in terms of bending angle and shear displacement was determined by performing regression analysis on the experimental data. The threshold values of the bending angle (16.2 deg) and shear displacement (25.2 mm) estimated from the injury threshold function were in agreement with previously published knee injury threshold data. The continuous knee injury function expressed in terms of bending angle and shear displacement enabled injury prediction for combined loading conditions such as those observed in pedestrian-car collisions.

  2. Joint proprioception, muscle strength, and functional ability in patients with osteoarthritis of the knee.

    PubMed

    van der Esch, M; Steultjens, M; Harlaar, J; Knol, D; Lems, W; Dekker, J

    2007-06-15

    To test the hypotheses that poor knee joint proprioception is related to limitations in functional ability, and poor proprioception aggravates the impact of muscle weakness on limitations in functional ability in osteoarthritis (OA) of the knee. Sixty-three patients with symptomatic OA of the knee were tested. Proprioceptive acuity was assessed by establishing the joint motion detection threshold (JMDT) in the anteroposterior direction. Muscle strength was measured using a computer-driven isokinetic dynamometer. Functional ability was assessed by the 100-meter walking test, the Get Up and Go (GUG) test, and the Western Ontario and McMaster Universities Osteoarthritis Index physical function (WOMAC-PF) questionnaire. Correlation analyses were performed to assess the relationship between proprioception, muscle strength, and functional ability. Regression analyses were performed to assess the impact of proprioception on the relationship between muscle strength and functional ability. Poor proprioception (high JMDT) was related to more limitation in functional ability (walking time r = 0.30, P < 0.05; GUG time r = 0.30, P < 0.05; WOMAC-PF r = 0.26, P <0.05). In regression analyses, the interaction between proprioception and muscle strength was significantly related to functional ability (walking time, P < 0.001 and GUG time, P < 0.001) but not to WOMAC-PF score (P = 0.625). In patients with poor proprioception, reduction of muscle strength was associated with more severe deterioration of functional ability than in patients with accurate proprioception. Patients with poor proprioception show more limitation in functional ability, but this relationship is rather weak. In patients with poor proprioception, muscle weakness has a stronger impact on limitations in functional ability than in patients with accurate proprioception.

  3. Evaluation of a knee-kicker bumper design for reducing knee morbidity among carpet layers.

    PubMed

    Huang, Wan-Fu; Wu, Chih-Fu

    2012-09-01

    Carpet layers have a high prevalence of occupational knee morbidity. One of the main causes is that they need to frequently 'kick' the bumper on the rear end of the knee kicker with one knee when laying a carpet. Considering the bumper's marked effects on kicking force transmission and safety, this study aims to improve the design of the knee-kicker bumper by reducing the risk factors. An improved pendulum-type impact-testing platform was designed as an evaluative apparatus, with the impulse and the coefficient of restitution serving as evaluative criteria. The newly developed bumper has improved firmness from drilled blind holes and an increase in effective forward force of 15%-138%, which implies lower operational demands and a lighter knee burden (i.e., less kicking energy results in the same work efficiency), and a softer contact surface that enhances operating comfort. The newly designed kicker was positively reviewed by subjects. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  4. Ground reaction forces and knee kinetics during single and repeated badminton lunges.

    PubMed

    Lam, Wing Kai; Ding, Rui; Qu, Yi

    2017-03-01

    Repeated movement (RM) lunge that frequently executed in badminton might be used for footwear evaluation. This study examined the influence of single movement (SM) and RM lunges on the ground reaction forces (GRFs) and knee kinetics during the braking phase of a badminton lunge step. Thirteen male university badminton players performed left-forward lunges in both SM and RM sessions. Force platform and motion capturing system were used to measure GRFs and knee kinetics variables. Paired t-test was performed to determine any significant differences between SM and RM lunges regarding mean and coefficient of variation (CV) in each variable. The kinetics results indicated that compared to SM lunges, the RM lunges had shorter contact time and generated smaller maximum loading rate of impact force, peak knee anterior-posterior force, and peak knee sagittal moment but generated larger peak horizontal resultant forces (Ps < 0.05). Additionally, the RM lunges had lower CV for peak knee medial-lateral and vertical forces (Ps < 0.05). These results suggested that the RM testing protocols had a distinct loading response and adaptation pattern during lunge and that the RM protocol showed higher within-trial reliability, which may be beneficial for the knee joint loading evaluation under different interventions.

  5. Differences in neuromuscular control between impact and no impact roundhouse kick in athletes of different skill levels.

    PubMed

    Quinzi, Federico; Camomilla, Valentina; Felici, Francesco; Di Mario, Alberto; Sbriccoli, Paola

    2013-02-01

    This study aimed at investigating two aspects of neuromuscular control around the hip and knee joint while executing the roundhouse kick (RK) using two techniques: Impact RK (IRK) at trunk level and No-Impact RK at face level (NIRK). The influence of technical skill level was also investigated by comparing two groups: elite Karateka and Amateurs. Surface electromyographic (sEMG) signals have been recorded from the Vastus Lateralis (VL), Biceps Femoris (BF), Rectus Femoris (RF), Gluteus Maximum (GM) and Gastrocnemious (GA) muscles of the kicking leg in six Karateka and six Amateurs performing the RKs. Hip and knee kinematics were also assessed. EMG data were rectified, filtered and normalized to the maximal value obtained for each muscle over all trials; co-activation (CI) indexes of antagonist vs. overall (agonist and antagonist) activity were computed for hip and knee flexion and extension. Muscle Fiber Conduction Velocity (CV) obtained from VL and BF muscles was assessed as well. The effect of group and kick on angular velocity, CIs, and CVs was tested through a two-way ANOVA (p < 0.05). An effect of group was showed in both kicks. Karateka presented higher knee and hip angular velocity; higher BF-CV (IRK: 5.1 ± 1.0 vs. 3.5 ± 0.5 m/s; NIRK: 5.7 ± 1.3 vs. 4.1 ± 0.5 m/s), higher CIs for hip movements and knee flexion and lower CI for knee extension. The results obtained suggest the presence of a skill-dependent activation strategy in the execution of the two kicks. CV results are suggestive of an improved ability of elite Karateka to recruit fast MUs as a part of training induced neuromuscular adaptation. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Relationships Between Age at Menarche, Walking Gait Base of Support, and Stance Phase Frontal Plane Knee Biomechanics in Adolescent Girls.

    PubMed

    Froehle, Andrew W; Grannis, Kimberly A; Sherwood, Richard J; Duren, Dana L

    2017-05-01

    Age at menarche impacts patterns of pubertal growth and skeletal development. These effects may carry over into variation in biomechanical profiles involved in sports-related traumatic and overuse knee injuries. The present study investigated whether age at menarche is a potential indicator of knee injury risk through its influence on knee biomechanics during normal walking. To test the hypothesis that earlier menarche is related to postpubertal biomechanical risk factors for knee injuries, including a wider, more immature gait base of support, and greater valgus knee angles and moments. Cross-sectional observational study. University research facility. Healthy, postmenarcheal, adolescent girls. Age at menarche was obtained by recall questionnaire. Pubertal growth and anthropometric data were collected by using standard methods. Biomechanical data were taken from tests of walking gait at self-selected speed. Reflective marker position data were collected with a 3-dimensional quantitative motion analysis system, and 3 force plates recorded kinetic data. Age at menarche; growth and anthropometric measurements; base of support; static knee frontal plane angle; and dynamic knee frontal plane angles and moments during stance. Earlier menarche was correlated significantly with abbreviated pubertal growth and postpubertal retention of immature traits, including a wider base of support. Earlier menarche and wider base of support were both correlated with more valgus static knee angles, more valgus knee abduction angles and moments at foot-strike, and a more valgus peak knee abduction angle during stance. Peak knee abduction moment during stance was not correlated with age at menarche or base of support. Earlier menarche and its effects on growth are associated with retention of a relatively immature gait base of support and a tendency for static and dynamic valgus knee alignment. This biomechanical profile may put girls with earlier menarche at greater risk for sports-related knee injuries. Not applicable. Copyright © 2017 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  7. Relationships between age at menarche, walking gait base of support, and stance phase frontal plane knee biomechanics in adolescent females

    PubMed Central

    Grannis, Kimberly A.; Sherwood, Richard J.; Duren, Dana L

    2016-01-01

    Background Age at menarche impacts patterns of pubertal growth and skeletal development. These effects may carry over into variation in biomechanical profiles involved in sports-related traumatic and overuse knee injuries. The present study investigated whether age at menarche is a potential indicator of knee injury risk through its influence on knee biomechanics during normal walking. Objective To test the hypothesis that earlier menarche is related to post-pubertal biomechanical risk factors for knee injuries, including a wider, more immature gait base of support, and greater valgus knee angles and moments. Design Cross-sectional observational study. Setting University research facility. Participants Healthy, post-menarcheal, adolescent females. Methods Age at menarche was obtained by recall questionnaire. Pubertal growth and anthropometric data were collected using standard methods. Biomechanical data were taken from tests of walking gait at self-selected speed. Reflective marker position data were collected using a three-dimensional quantitative motion analysis system, and three force plates recorded kinetic data. Main Outcome Measures Age at menarche; growth and anthropometric measurements; base of support; static knee frontal plane angle; dynamic knee frontal plane angles and moments during stance. Results Earlier menarche was significantly correlated with abbreviated pubertal growth and post-pubertal retention of immature traits, including a wider base of support. Earlier menarche and wider base of support were both correlated with more valgus static knee angles, more valgus knee abduction angles and moments at foot-strike, and a more valgus peak knee abduction angle during stance. Peak knee abduction moment during stance was not correlated with age at menarche or base of support. Conclusions Earlier menarche and its effects on growth are associated with retention of a relatively immature gait base of support and a tendency for static and dynamic valgus knee alignment. This biomechanical profile may put girls with earlier menarche at higher risk for sports-related knee injuries. PMID:27485675

  8. 49 CFR 572.77 - Instrumentation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Instrumentation. 572.77 Section 572.77 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY... Instrumentation. (a)(1) Test probe. For the head, thorax, and knee impact test, use a test probe that is rigid, of...

  9. 49 CFR 572.77 - Instrumentation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Instrumentation. 572.77 Section 572.77 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY... Instrumentation. (a)(1) Test probe. For the head, thorax, and knee impact test, use a test probe that is rigid, of...

  10. 49 CFR 572.77 - Instrumentation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Instrumentation. 572.77 Section 572.77 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY... Instrumentation. (a)(1) Test probe. For the head, thorax, and knee impact test, use a test probe that is rigid, of...

  11. 49 CFR 572.77 - Instrumentation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Instrumentation. 572.77 Section 572.77 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY... Instrumentation. (a)(1) Test probe. For the head, thorax, and knee impact test, use a test probe that is rigid, of...

  12. Specialized neuromuscular training to improve neuromuscular function and biomechanics in a patient with quiescent juvenile rheumatoid arthritis.

    PubMed

    Myer, Gregory D; Brunner, Hermine I; Melson, Paula G; Paterno, Mark V; Ford, Kevin R; Hewett, Timothy E

    2005-08-01

    The purpose of this case report is to describe a novel multidisciplinary approach for evaluating and preparing a patient with quiescent juvenile rheumatoid arthritis (JRA) for safe sports participation. The patient was a 10-year-old girl with a history of bilateral knee arthritis who desired to participate in soccer and basketball. Range of motion and manual muscle testing of the lower extremity were within normal limits. Neuromuscular testing included kinematic and kinetic testing, isokinetic assessment, and postural stability testing. The patient's gait was near normal; however, she had narrowed step width and increased knee flexion at heel-strike. Landing analysis during a box drop vertical jump task showed increased and imbalanced (right versus left lower extremity) peak impact forces. The testing was followed by specialized neuromuscular training (SNT). Following SNT, heel-strike and step width were within normal limits, peak impact forces on the box drop test decreased by 31%, imbalance decreased by 46%, and vertical jump increased 15%. The isokinetic strength ratio between knee flexors and extensors and the overall balance measures were within normal limits and equal bilaterally. Patients with quiescent JRA may have abnormal biomechanics, which could place them at increased risk for injury or future articular cartilage damage. Specialized neuromuscular training may have helped to decrease the patient's risk for future injury or disease progression.

  13. Safety assessment characteristics of pedestrian legform impactors in vehicle-front impact tests.

    PubMed

    Matsui, Yasuhiro

    2014-12-01

    This study investigated the characteristics of safety assessment results of front-area vehicle impact tests carried out using the Transport Research Laboratory (TRL) legform impactor and a flexible legform impactor (FLEX legform impactor). Different types of vehicles (sedan, sport utility vehicle, high-roof K-car, and light cargo van) were examined. The impact locations in the study were the center of the bumper and an extremely stiff structure of the bumper (i.e., in front of the side member) of each tested vehicle. The measured injury criteria were normalized by injury assessment reference values of each legform impactor. The test results for center and side-member impacts indicated that there were no significant differences in ligament injury assessments derived from the normalized knee ligament injury measures between the TRL legform impactor and the FLEX legform impactor. Evaluations made using the TRL legform impactor and the FLEX legform impactor are thus similar in the vehicle safety investigation for knee ligament injury. Vehicle-center impact test results revealed that the tibia fracture assessments derived from the normalized tibia fracture measures did not significantly differ between the TRL legform impactor and the FLEX legform impactor. However, for an impact against an extremely stiff structure, there was a difference in the tibia fracture assessment between the FLEX legform impactor and the TRL legform impactor owing to their different sensor types. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. An Accelerometer as an Alternative to a Force Plate for the Step-Up-and-Over Test.

    PubMed

    Bailey, Christopher A; Costigan, Patrick A

    2015-12-01

    The step-up-and-over test has been used successfully to examine knee function after knee injury. Knee function is quantified using the following variables extracted from force plate data: the maximal force exerted during the lift, the maximal impact force at landing, and the total time to complete the step. For various reasons, including space and cost, it is unlikely that all clinicians will have access to a force plate. The purpose of the study was to determine if the step-up-and-over test could be simplified by using an accelerometer. The step-up-and-over test was performed by 17 healthy young adults while being measured with both a force plate and a 3-axis accelerometer mounted at the low back. Results showed that the accelerometer and force plate measures were strongly correlated for all 3 variables (r = .90-.98, Ps < .001) and that the accelerometer values for the lift and impact indices were 6-7% higher (Ps < .01) and occurred 0.07-0.1 s later than the force plate (Ps < .05). The accelerometer returned values highly correlated to those from a force plate. Compared with a force plate, a wireless, 3-axis accelerometer is a less expensive and more portable system with which to measure the step-up-and-over test.

  15. Effect of unilateral and bilateral use of laterally wedged insoles with arch supports on impact loading in medial knee osteoarthritis.

    PubMed

    Abd El Megeid Abdallah, Amira Abdallah

    2016-04-01

    Increased impact loading is implicated in knee osteoarthritis development and progression. This study examined the impact ground reaction force (GRF) peak, its loading rate, its relative timing to stance phase timing, and walking speed during unilateral and bilateral use of laterally wedged insoles with arch supports. Within-subject design. Thirty-three female patients with medial knee osteoarthritis were examined with (unilateral 6° and 11°, and bilateral 0°, 6°, and 11°) and without insole use. Repeated measures MANOVA revealed that the impact force increased significantly in bilateral 11° versus unilateral 6° and without-insole conditions. The loading rate decreased significantly in unilateral 11° versus bilateral 6° insoles. The relative timing increased significantly in each of bilateral 6°, bilateral 11°, and unilateral 11° versus bilateral 0° insoles and in each of bilateral 11° and unilateral 11° versus without-insole condition. There were significant positive correlations between the walking speed and each of the force and loading rate. The Chi-square test revealed insignificant association between the insole condition and the presence of impact forces. Unilateral 11° insoles are capable of reducing impact loading possibly through increasing foot pronation. Walking slowly is another possible strategy to reduce loading. Unilaterally applied 11° laterally wedged insoles are capable of reducing and delaying the initial impact ground reaction forces and reducing their loading rates during walking in patients with medial knee osteoarthritis, thus reducing osteoarthritis progression. Walking slowly could also be used as a strategy to reduce impact loading. © The International Society for Prosthetics and Orthotics 2015.

  16. The effect of ankle bracing on knee kinetics and kinematics during volleyball-specific tasks.

    PubMed

    West, T; Ng, L; Campbell, A

    2014-12-01

    The purpose of this study was to examine the effects of ankle bracing on knee kinetics and kinematics during volleyball tasks. Fifteen healthy, elite, female volleyball players performed a series of straight-line and lateral volleyball tasks with no brace and when wearing an ankle brace. A 14-camera Vicon motion analysis system and AMTI force plate were used to capture the kinetic and kinematic data. Knee range of motion, peak knee anterior-posterior and medial-lateral shear forces, and peak ground reaction forces that occurred between initial contact with the force plate and toe off were compared using paired sample t-tests between the braced and non-braced conditions (P < 0.05). The results revealed no significant effect of bracing on knee kinematics or ground reaction forces during any task or on knee kinetics during the straight-line movement volleyball tasks. However, ankle bracing was demonstrated to reduce knee lateral shear forces during all of the lateral movement volleyball tasks. Wearing the Active Ankle T2 brace will not impact knee joint range of motion and may in fact reduce shear loading to the knee joint in volleyball players. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Experimental research on pedestrian lower leg impact

    NASA Astrophysics Data System (ADS)

    Constantin, B. A.; Iozsa, D. M.; Stan, C.

    2017-10-01

    The present paper is centred on the research of deceleration measured at the level of the lower leg during a pedestrian impact in multiple load cases. Basically, the used methodology for physical test setup is similar to EuroNCAP and European Union regulatory requirements. Due cost reduction reasons, it was not used a pneumatic system in order to launch the lower leg impactor in the direction of the vehicle front-end. During the test it was used an opposite solution, namely the vehicle being in motion, aiming the standstill lower leg impactor. The impactor has similar specifications to those at EU level, i.e. dimensions, materials, and principle of measurement of the deceleration magnitude. Therefore, all the results obtained during the study comply with the requirements of both EU regulation and EuroNCAP. As a limitation, due to unavailability of proper sensors in the equipment of the lower leg impactor, that could provide precise results, the bending angle, the shearing and the detailed data at the level of knee ligaments were not evaluated. The knee joint should be improved for future studies as some bending angles observed during the post processing of several impact video files were too high comparing to other studies. The paper highlights the first pedestrian impact physical test conducted by the author, following an extensive research in the field. Deceleration at the level of pedestrian knee can be substantially improved by providing enough volume between the bumper fascia and the front-end structure and by using pedestrian friendly materials for shock absorbers, such as foams.

  18. Changes in self-reported knee function and health-related quality of life after knee injury in female athletes.

    PubMed

    McGuine, Timothy A; Winterstein, Andrew; Carr, Kathleen; Hetzel, Scott; Scott, Jessica

    2012-07-01

    To document the changes in self-reported health-related quality of life and knee function in a cohort of young female athletes who have sustained a knee injury. Prospective cohort. An outpatient sports medicine clinic and university student health service. A convenience sample of 255 females (age = 17.4 ± 2.4 years) who injured their knee participating in sport or recreational activities. Injuries were categorized as anterior cruciate ligament tears, anterior knee pain, patellar instability, meniscus tear, collateral ligament sprain, and other. Knee function was assessed with the 2000 International Knee Documentation Committee (IKDC) knee survey. Health-related quality of life was assessed with the SF-12 version 2.0 (acute) survey (SF-12). Dependent variables included the paired differences in the 2000 IKDC and SF-12 subscales, and composite scores from preinjury to diagnosis. Paired differences were assessed with paired t tests (P < 0.05) reported as the mean ± SD. International Knee Documentation Committee scores at diagnosis were significantly lower than preinjury scores (P < 0.001). SF-12 scores were lower (P < 0.001) at diagnosis for each subscale (physical functioning, role physical, bodily pain, general health, vitality, social function, role emotional, and mental health) as well as the physical and mental composite scores. In addition to negatively affecting knee function, sport medicine providers should be aware that knee injuries can negatively impact the health-related quality of life in these athletes immediately after injury.

  19. Swollen Knee (Water on the Knee)

    MedlinePlus

    ... your knee joint. Some people call this condition "water on the knee." A swollen knee may be ... Choose low-impact exercise. Certain activities, such as water aerobics and swimming, don't place continuous weight- ...

  20. Mechanisms and factors involved in hip injuries during frontal crashes.

    PubMed

    Yoganandan, N; Pintar, F A; Gennarelli, T A; Maltese, M R; Eppinger, R H

    2001-11-01

    This study was conducted to collect data and gain insights relative to the mechanisms and factors involved in hip injuries during frontal crashes and to study the tolerance of hip injuries from this type of loading. Unembalmed human cadavers were seated on a standard automotive seat (reinforced) and subjected to knee impact test to each lower extremity. Varying combinations of flexion and adduction/abduction were used for initial alignment conditions and pre-positioning. Accelerometers were fixed to the iliac wings and twelfth thoracic vertebral spinous process. A 23.4-kg padded pendulum impacted the knee at velocities ranging from 4.3 to 7.6 m/s. The impacting direction was along the anteroposterior axis, i.e., the global X-axis, in the body-fixed coordinate system. A load cell on the front of the pendulum recorded the impact force. Peak impact forces ranged from 2,450 to 10,950 N. The rate of loading ranged from 123 to 7,664 N/msec. The impulse values ranged from 12.4 to 31.9 Nsec. Injuries were not apparent in three tests. Eight tests resulted in trauma. Fractures involving the pelvis including the acetabulum and proximal femur occurred in five out of the eight tests, and distal femoral bone fracture occurred in one test. These results underscore the importance of leg pre-positioning and the orientation of the impacting axis to produce specific types of trauma to the pelvic region of the lower extremity.

  1. Multiple Nonspecific Sites of Joint Pain Outside the Knees Develop in Persons With Knee Pain.

    PubMed

    Felson, David T; Niu, Jingbo; Quinn, Emily K; Neogi, Tuhina; Lewis, Cara L; Lewis, Cora E; Frey Law, Laura; McCulloch, Chuck; Nevitt, Michael; LaValley, Michael

    2017-02-01

    Many persons with knee pain have joint pain outside the knee, but despite the impact and high frequency of this pain, its distribution and causes have not been studied. We undertook this study to test the hypothesis of those studying gait abnormalities who have suggested that knee pain causes pain in adjacent joints but that pain adaptation strategies are highly individualized. We studied persons ages 50-79 years with or at high risk of knee osteoarthritis who were recruited from 2 community-based cohorts, the Multicenter Osteoarthritis Study and the Osteoarthritis Initiative, and we followed them up for 5-7 years. We excluded those with knee pain at baseline and compared those who had developed knee pain at the first follow-up examination (the index visit) with those who had not. We examined pain on most days at joint regions outside the knee in examinations after the index visit. Logistic regression analyses examined the risk of joint-specific pain adjusted for age, sex, body mass index, and symptoms of depression, and we performed sensitivity analyses excluding those with widespread pain. In the combined cohorts, 693 persons had knee pain at the index visit and 2,793 did not. A total of 79.6% of those with bilateral knee pain and 63.8% of those with unilateral knee pain had pain during follow-up in a joint region outside the knee, compared with 49.9% of those without knee pain. There was an increased risk of pain at most extremity joint sites, without a predilection for specific sites. Results were unchanged when those with widespread pain were excluded. Persons with chronic knee pain are at increased risk of pain in multiple joints in no specific pattern. © 2016, American College of Rheumatology.

  2. Unicondylar arthroplasty in knees with deficient anterior cruciate ligaments.

    PubMed

    Engh, Gerard A; Ammeen, Deborah J

    2014-01-01

    Historically, a functional ACL has been a prerequisite for patients undergoing unicondylar knee arthroplasty (UKA). However, this premise has not been rigorously tested. We compared (1) the survivorship free from revision and (2) the failure mechanisms of UKAs in ACL-deficient knees and UKAs in ACL-intact knees performed over the same time interval. Between November 2000 and July 2008, a fixed bearing UKA was performed in 72 patients (81 knees) with intraoperatively confirmed ACL deficiency. Five patients (five knees) with preoperative instability underwent ACL reconstruction and were excluded from analysis. Of the remaining 67 patients (76 knees) without preoperative instability, implant status was known for 68 UKAs in 60 patients. Survivorship and failure mechanisms for these knees were compared to those of 706 UKAs in ACL-intact knees performed during the same time interval by the same surgeon using the same implant system. Minimum followup for the ACL-deficient group was 2.9 years (mean, 6 years; range, 2.9-10 years). Revision rates between UKAs with and without intact ACLs were similar in the absence of clinical instability (p = 0.58). Six-year UKA survivorship was 94% (95% CI: 88%-100%) in ACL-deficient knees and 93% (95% CI: 91%-96%) in ACL-intact knees (p = 0.89). Five knees (7%) in the ACL-deficient group were revised: disease progression (two), loose tibia (one), persistent pain (one), and revised elsewhere/reason unknown (one). Thirty-six knees in the ACL-intact group underwent revision (5%): aseptic loosening (13), revised elsewhere/reason unknown (11), disease progression (three), tibial subsidence/fracture (four), infection (three), pain (one), and lateral compartment overload (one). At 6 years, deficiency of the ACL in patients without clinical knee instability did not impact the survivorship of UKAs compared to UKAs performed in knees with intact ACLs.

  3. Impact of concurrent foot pain on health and functional status in people with knee osteoarthritis: data from the osteoarthritis initiative.

    PubMed

    Paterson, Kade L; Hinman, Rana S; Hunter, David J; Wrigley, Tim V; Bennell, Kim L

    2015-07-01

    To document the prevalence of foot pain and foot pain laterality in people with knee osteoarthritis (OA) and to examine its impact on health and function. Participants from the Progression subcohort (n = 1,255, ages 45-79 years) of the Osteoarthritis Initiative with symptomatic tibiofemoral knee OA were included. Prevalence of foot pain, defined as pain in the foot/ankle, and foot pain laterality were determined. Health status was evaluated using the Western Ontario and McMaster Universities Osteoarthritis Index, the Short Form-12 Health Survey, and the Center for Epidemiological Studies Depression Scale. Function was assessed using the 20-meter walk test (WT) and a repeated chair stand test. Differences in health and functional measures were compared between groups with and without foot pain using multivariate analysis of covariance. One-fourth (n = 317 [25%]) of people with knee OA experienced concurrent foot pain, with the majority (n = 174 [55%]) reporting pain in both feet. After adjusting for covariates, people with foot pain scored worse on all health measures and on the 20-meter WT, compared to those without (P < 0.05). Differences in health and function were found between the bilateral and ipsilateral foot pain groups compared to those without foot pain (P < 0.05), but no differences were found with the contralateral group. Foot pain is common in people with knee OA, and bilateral and ipsilateral foot pain adversely affect health and function, suggesting laterality is important. Further research is needed to establish the mechanism and interaction of pathology at these sites and to evaluate foot pain treatment in this population. © 2015, American College of Rheumatology.

  4. Concurrent foot pain is common in people with knee osteoarthritis and impacts health and functional status: data from the Osteoarthritis Initiative

    PubMed Central

    Paterson, Kade L; Hinman, Rana S; Hunter, David J; Wrigley, Tim V; Bennell, Kim L

    2015-01-01

    Objective To document the prevalence of foot pain and foot pain laterality in people with knee osteoarthritis (OA), and to examine its impact on health and function. Methods Participants from the Progression subcohort (n=1255, aged 45-79 years) of the Osteoarthritis Initiative with symptomatic tibiofemoral knee OA were included. Prevalence of foot pain, defined as pain in the foot/ankle, and foot pain laterality was determined. Health status was evaluated using the Western Ontario and McMaster Universities Osteoarthritis Index, the Short Form-12 and the Centre for Epidemiological Studies Depression Scale. Function was assessed using the 20-meter walk test (20MWT) and a repeated chair stand test. Differences in health and functional measures were compared between groups with and without foot pain using multivariate analysis of covariance. Results One quarter (n=317, 25%) of people with knee OA experienced concurrent foot pain, with the majority (n=174, 55%) reporting pain in both feet. After adjusting for covariates, people with foot pain scored worse on all health measures and on the 20MWT compared to those without (p<0.05). Differences in health and function were found between the bilateral and ispilateral foot pain groups compared to those without foot pain (p<0.05), however no differences were found with the contralateral group. Conclusion Foot pain is common in people with knee OA, and bilateral and ipsilateral foot pain adversely affects health and function suggesting laterality is important. Further research is needed to establish the mechanism and interaction of pathology at these sites, and to evaluate foot pain treatment in this population. PMID:25581254

  5. Soldier-relevant loads impact lower limb biomechanics during anticipated and unanticipated single-leg cutting movements.

    PubMed

    Brown, Tyler N; O'Donovan, Meghan; Hasselquist, Leif; Corner, Brian; Schiffman, Jeffrey M

    2014-11-07

    This study quantified how body borne load impacts hip and knee biomechanics during anticipated and unanticipated single-leg cutting maneuvers. Fifteen male military personnel performed a series of single-leg cutting maneuvers with three different load configurations (light, ~6 kg, medium, ~20 kg, and heavy, ~40 kg). Subject-based means of the specific lower limb biomechanical variables were submitted to repeated measures ANOVA to test the main and interaction effects of body borne load and movement type. With body borne load, stance time (P<0.001) increased, while larger hip (P=0.027) and knee flexion (P=0.004), and hip adduction (P<0.001) moments, and decreased hip (P=0.002) and knee flexion (P<0.001), and hip adduction (P=0.003) postures were evident. Further, the hip (P<0.001) and ankle (P=0.024) increased energy absorption, while the knee (P=0.020) increased energy generation with body borne load. During the unanticipated maneuvers, the hip (P=0.009) and knee (P=0.032) increased energy generation, and peak hip flexion moment (P=0.002) increased relative to the anticipated movements. With the body borne load, participants adopted biomechanical patterns that decreased their locomotive ability including larger moments and reduced flexion postures of the lower limb. During the single-leg cut, participants used greater energy absorption from the large, proximal muscles of the hip and greater energy generation from the knee with the addition of load. Participant's performance when carrying a range of loads was not compromised by anticipation, as they did not exhibit the hip and knee kinetic and kinematic adaptations previously demonstrated when reacting to an unplanned stimulus. Published by Elsevier Ltd.

  6. Assessment of knee laxity using a robotic testing device: a comparison to the manual clinical knee examination.

    PubMed

    Branch, T P; Stinton, S K; Siebold, R; Freedberg, H I; Jacobs, C A; Hutton, W C

    2017-08-01

    The purpose of this study was to collect knee laxity data using a robotic testing device. The data collected were then compared to the results obtained from manual clinical examination. Two human cadavers were studied. A medial collateral ligament (MCL) tear was simulated in the left knee of cadaver 1, and a posterolateral corner (PLC) injury was simulated in the right knee of cadaver 2. Contralateral knees were left intact. Five blinded examiners carried out manual clinical examination on the knees. Laxity grades and a diagnosis were recorded. Using a robotic knee device which can measure knee laxity in three planes of motion: anterior-posterior, internal-external tibia rotation, and varus-valgus, quantitative data were obtained to document tibial motion relative to the femur. One of the five examiners correctly diagnosed the MCL injury. Robotic testing showed a 1.7° larger valgus angle, 3° greater tibial internal rotation, and lower endpoint stiffness (11.1 vs. 24.6 Nm/°) in the MCL-injured knee during varus-valgus testing when compared to the intact knee and 4.9 mm greater medial tibial translation during rotational testing. Two of the five examiners correctly diagnosed the PLC injury, while the other examiners diagnosed an MCL tear. The PLC-injured knee demonstrated 4.1 mm more lateral tibial translation and 2.2 mm more posterior tibial translation during varus-valgus testing when compared to the intact knee. The robotic testing device was able to provide objective numerical data that reflected differences between the injured knees and the uninjured knees in both cadavers. The examiners that performed the manual clinical examination on the cadaver knees proved to be poor at diagnosing the injuries. Robotic testing could act as an adjunct to the manual clinical examination by supplying numbers that could improve diagnosis of knee injury. Level II.

  7. Impact attenuation properties of jazz shoes alter lower limb joint stiffness during jump landings.

    PubMed

    Fong Yan, Alycia; Smith, Richard M; Hiller, Claire E; Sinclair, Peter J

    2017-05-01

    To quantify the impact attenuation properties of the jazz shoes, and to investigate the in-vivo effect of four jazz shoe designs on lower limb joint stiffness during a dance-specific jump. Repeated measures. A custom-built mechanical shoe tester similar to that used by athletic shoe companies was used to vertically impact the forefoot and heel region of four different jazz shoe designs. Additionally, dancers performed eight sautés in second position in bare feet and the shoe conditions. Force platforms and 3D-motion capture were used to analyse the joint stiffness of the midfoot, ankle, knee and hip during the jump landings. Mechanical testing of the jazz shoes revealed significant differences in impact attenuation characteristics among each of the jazz shoe designs. Gross knee and midfoot joint stiffness were significantly affected by the jazz shoe designs in the dancers' jump landings. The tested jazz shoe designs altered the impact attenuating capacity of jump landing technique in dancers. The cushioned jazz shoes are recommended particularly for injured dancers to reduce impact on the lower limb. Jazz shoe design should consider the impact attenuation properties of the forefoot region, due to the toe-strike landing technique in dance movement. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  8. The relationship between quadriceps muscle force, knee flexion, and anterior cruciate ligament strain in an in vitro simulated jump landing.

    PubMed

    Withrow, Thomas J; Huston, Laura J; Wojtys, Edward M; Ashton-Miller, James A

    2006-02-01

    An instrumented cadaveric knee construct was used to quantify the association between impact force, quadriceps force, knee flexion angle, and anterior cruciate ligament relative strain in simulated unipedal jump landings. Anterior cruciate ligament strain will correlate with impact force, quadriceps force, and knee flexion angle. Descriptive laboratory study. Eleven cadaveric knees (age, 70.8 [19.3] years; 5 male; 6 female) were mounted in a custom fixture with the tibia and femur secured to a triaxial load cell. Quadriceps, hamstring, and gastrocnemius muscle forces were simulated using pretensioned steel cables (stiffness, 7 kN/cm), and the quadriceps tendon force was measured using a load cell. Mean strain on the anteromedial bundle of the anterior cruciate ligament was measured using a DVRT. With the knee in 25 degrees of flexion, the construct was vertically loaded by an impact force initially directed 4 cm posterior to the knee joint center. Tibiofemoral kinematics was measured using a 3D optoelectronic tracking system. The increase in anterior cruciate ligament relative strain was proportional to the increase in quadriceps force (r(2) = 0.74; P < .00001) and knee flexion angle (r(2) = 0.88; P < .00001) but was not correlated with the impact force (r(2) = 0.009; P = .08). The increase in knee flexion and quadriceps force during this simulated 1-footed landing strongly influenced the relative strain on the anteromedial bundle of the anterior cruciate ligament. These results suggest that even in the presence of knee flexor muscle forces, the increase in quadriceps force required to prevent the knee from flexing during landing can place the anterior cruciate ligament at risk for large strains.

  9. Diagnostic Value of Knee Arthrometry in the Prediction of Anterior Cruciate Ligament Strain During Landing

    PubMed Central

    Kiapour, Ata M.; Wordeman, Samuel C.; Paterno, Mark V.; Quatman, Carmen E.; Levine, Jason W.; Goel, Vijay K.; Demetropoulos, Constantine K.; Hewett, Timothy E.

    2014-01-01

    Background Previous studies have indicated that higher knee joint laxity may be indicative of an increased risk of anterior cruciate ligament (ACL) injuries. Despite the frequent clinical use of knee arthrometry in the evaluation of knee laxity, little data exist to correlate instrumented laxity measures and ACL strain during dynamic high-risk activities. Purpose/Hypotheses The purpose of this study was to evaluate the relationships between ACL strain and anterior knee laxity measurements using arthrometry during both a drawer test and simulated bipedal landing (as an identified high-risk injurious task). We hypothesized that a high correlation exists between dynamic ACL strain and passive arthrometry displacement. The secondary hypothesis was that anterior knee laxity quantified by knee arthrometry is a valid predictor of injury risk such that specimens with greater anterior knee laxity would demonstrate increased levels of peak ACL strain during landing. Study Design Controlled laboratory study. Methods Twenty cadaveric lower limbs (mean age, 46 ± 6 years; 10 female and 10 male) were tested using a CompuKT knee arthrometer to measure knee joint laxity. Each specimen was tested under 4 continuous cycles of anterior-posterior shear force (±134 N) applied to the tibial tubercle. To quantify ACL strain, a differential variable reluctance transducer (DVRT) was arthroscopically placed on the ACL (anteromedial bundle), and specimens were retested. Subsequently, bipedal landing from 30 cm was simulated in a subset of 14 specimens (mean age, 45 ± 6 years; 6 female and 8 male) using a novel custom-designed drop stand. Changes in joint laxity and ACL strain under applied anterior shear force were statistically analyzed using paired sample t tests and analysis of variance. Multiple linear regression analyses were conducted to determine the relationship between anterior shear force, anterior tibial translation, and ACL strain. Results During simulated drawer tests, 134 N of applied anterior shear load produced a mean peak anterior tibial translation of 3.1 ± 1.1 mm and a mean peak ACL strain of 4.9% ± 4.3%. Anterior shear load was a significant determinant of anterior tibial translation (P <.0005) and peak ACL strain (P = .04). A significant correlation (r = 0.52, P <.0005) was observed between anterior tibial translation and ACL strain. Cadaveric simulations of landing produced a mean axial impact load of 4070 ± 732 N. Simulated landing significantly increased the mean peak anterior tibial translation to 10.4 ± 3.5 mm and the mean peak ACL strain to 6.8% ± 2.8% (P <.0005) compared with the prelanding condition. Significant correlations were observed between peak ACL strain during simulated landing and anterior tibial translation quantified by knee arthrometry. Conclusion Our first hypothesis is supported by a significant correlation between arthrometry displacement collected during laxity tests and concurrent ACL strain calculated from DVRT measurements. Experimental findings also support our second hypothesis that instrumented measures of anterior knee laxity predict peak ACL strain during landing, while specimens with greater knee laxity demonstrated higher levels of peak ACL strain during landing. Clinical Relevance The current findings highlight the importance of instrumented anterior knee laxity assessments as a potential indicator of the risk of ACL injuries in addition to its clinical utility in the evaluation of ACL integrity. PMID:24275863

  10. Assessment of Corrosion, Fretting, and Material Loss of Retrieved Modular Total Knee Arthroplasties.

    PubMed

    Martin, Audrey J; Seagers, Kirsten A; Van Citters, Douglas W

    2017-07-01

    Modular junctions in total hip arthroplasties have been associated with fretting, corrosion, and debris release. The purpose of this study is to analyze damage severity in total knee arthroplasties of a single design by qualitative visual assessment and quantitative material loss measurements to evaluate implant performance and patient impact via material loss. Twenty-two modular knee retrievals of the same manufacturer were identified from an institutional review board-approved database. Junction designs included tapers with an axial screw and tapers with a radial screw. Constructs consisted of 2 metal alloys: CoCr and Ti6Al4V. Components were qualitatively scored and quantitatively measured for corrosion and fretting. Negative values represent adhered material. Statistical differences were analyzed using sign tests. Correlations were tested with a Spearman rank order test (P < .05). The median volumetric material loss and the maximum linear depth for the total population were -0.23 mm 3 and 5.84 μm, respectively. CoCr components in mixed metal junctions had higher maximum linear depth (P = .007) than corresponding Ti components. Fretting scores of Ti6Al4V alloy components in mixed metal junctions were statistically higher than the remaining groups. Taper angle did not correlate with material loss. Results suggest that CoCr components in mixed metal junctions are more vulnerable to corrosion than other components, suggesting preferential corrosion when interfacing with Ti6Al4V. Overall, although corrosion was noted in this series, material loss was low, and none were revised for clinical metal-related reaction. This suggests the clinical impact from corrosion in total knee arthroplasty is low. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Sex-Based Differences in Knee Kinetics With Anterior Cruciate Ligament Strain on Cadaveric Impact Simulations

    PubMed Central

    Schilaty, Nathan D.; Bates, Nathaniel A.; Nagelli, Christopher; Krych, Aaron J.; Hewett, Timothy E.

    2018-01-01

    Background: Females are at an increased risk of sustaining noncontact knee ligament injuries as compared with their male counterparts. The kinetics that load the anterior cruciate ligament (ACL) are still under dispute in the literature. Purpose/Hypothesis: The purpose of this study was to determine whether there are differences in knee kinetics between the sexes that lead to greater ACL strain in females when similar external loads are applied during a simulated drop vertical jump landing task. It was hypothesized that female limbs would demonstrate significant differences in knee abduction moment that predispose females to ACL injury when compared with males. Study Design: Controlled laboratory study. Methods: Motion analysis data of 67 athletes who performed a drop vertical jump were collected. The kinematic and kinetic data were used to categorize tertiles of relative risk, and these values were input into a cadaveric impact simulator to assess ligamentous loads during the simulated landing task. Uni- and multiaxial load cells and differential variable reluctance transducer strain sensors were utilized to collect kinetic data and maximum ACL strain for analysis. Conditions of external loads applied to the cadaveric limbs were systematically varied and randomized. Data were analyzed with 2-way repeated-measures analysis of variance and the Fisher exact test. Results: Five kinetic parameters were evaluated. Of the 5 kinetic variables, only knee abduction moment (KAM) demonstrated significant differences in females as compared with males (F 1,136 = 4.398, P = .038). When normalized to height and weight, this difference between males and females increased in significance (F 1,136 = 7.155, P = .008). Compared with males, females exhibited a 10.3-N·m increased knee abduction torque at 66 milliseconds postimpact and a 22.3-N·m increased abduction torque at 100 milliseconds postimpact. For loading condition, the condition of “maximum ACL strain” demonstrated a maximum difference of 54.3-N·m increased abduction torque and 74.5-N·m increased abduction torque at 66 milliseconds postimpact. Conclusion: Under the tested conditions, increased external loads led to increased medial knee translation force, knee abduction moment, and external knee moment. Females exhibited greater forces and moments at the knee, especially at KAM, when loaded in similar conditions. As these KAM loads are associated with increased load and strain on the ACL, the sex-based differences observed in the present study may account for a portion of the underlying mechanics that predispose females to ACL injury as compared with males in a controlled simulated athletic task. Clinical Relevance: KAM increases strain to the ACL under clinically representative loading. Additionally, this work establishes the biomechanical characteristics of knee loading between sexes. PMID:29568787

  12. Sex-Based Differences in Knee Kinetics With Anterior Cruciate Ligament Strain on Cadaveric Impact Simulations.

    PubMed

    Schilaty, Nathan D; Bates, Nathaniel A; Nagelli, Christopher; Krych, Aaron J; Hewett, Timothy E

    2018-03-01

    Females are at an increased risk of sustaining noncontact knee ligament injuries as compared with their male counterparts. The kinetics that load the anterior cruciate ligament (ACL) are still under dispute in the literature. The purpose of this study was to determine whether there are differences in knee kinetics between the sexes that lead to greater ACL strain in females when similar external loads are applied during a simulated drop vertical jump landing task. It was hypothesized that female limbs would demonstrate significant differences in knee abduction moment that predispose females to ACL injury when compared with males. Controlled laboratory study. Motion analysis data of 67 athletes who performed a drop vertical jump were collected. The kinematic and kinetic data were used to categorize tertiles of relative risk, and these values were input into a cadaveric impact simulator to assess ligamentous loads during the simulated landing task. Uni- and multiaxial load cells and differential variable reluctance transducer strain sensors were utilized to collect kinetic data and maximum ACL strain for analysis. Conditions of external loads applied to the cadaveric limbs were systematically varied and randomized. Data were analyzed with 2-way repeated-measures analysis of variance and the Fisher exact test. Five kinetic parameters were evaluated. Of the 5 kinetic variables, only knee abduction moment (KAM) demonstrated significant differences in females as compared with males ( F 1,136 = 4.398, P = .038). When normalized to height and weight, this difference between males and females increased in significance ( F 1,136 = 7.155, P = .008). Compared with males, females exhibited a 10.3-N·m increased knee abduction torque at 66 milliseconds postimpact and a 22.3-N·m increased abduction torque at 100 milliseconds postimpact. For loading condition, the condition of "maximum ACL strain" demonstrated a maximum difference of 54.3-N·m increased abduction torque and 74.5-N·m increased abduction torque at 66 milliseconds postimpact. Under the tested conditions, increased external loads led to increased medial knee translation force, knee abduction moment, and external knee moment. Females exhibited greater forces and moments at the knee, especially at KAM, when loaded in similar conditions. As these KAM loads are associated with increased load and strain on the ACL, the sex-based differences observed in the present study may account for a portion of the underlying mechanics that predispose females to ACL injury as compared with males in a controlled simulated athletic task. KAM increases strain to the ACL under clinically representative loading. Additionally, this work establishes the biomechanical characteristics of knee loading between sexes.

  13. Associated lateral/medial knee instability and its relevant factors in anterior cruciate ligament-injured knees.

    PubMed

    Yuuki, Arata; Muneta, Takeshi; Ohara, Toshiyuki; Sekiya, Ichiro; Koga, Hideyuki

    2017-03-01

    Associations of lateral/medial knee instability with anterior cruciate ligament (ACL) injury have not been thoroughly investigated. The purposes of this study were to investigate whether lateral/medial knee instability is associated with ACL injury, and to clarify relevant factors for lateral/medial knee instability in ACL-injured knees. One hundred and nineteen patients with unilateral ACL-injured knees were included. Lateral/medial knee instability was assessed with varus/valgus stress X-ray examination for both injured and uninjured knees by measuring varus/valgus angle, lateral/medial joint opening, and lateral/medial joint opening index. Manual knee instability tests for ACL were evaluated to investigate associations between lateral/medial knee instability and anterior and/or rotational instabilities. Patients' backgrounds were evaluated to identify relevant factors for lateral/medial knee instability. Damage on the lateral collateral ligament (LCL) on MRI was also evaluated. All parameters regarding lateral knee instability in injured knees were significantly greater than in uninjured knees. There were significant correlations between lateral knee instability and the Lachman test as well as the pivot shift test. Patients with LCL damage had significantly greater lateral joint opening than those without LCL damage on MRI. Sensitivity of LCL damage on MRI to lateral joint opening was 100%, while its specificity was 36%. No other relevant factors were identified. In medial knee instability, there were also correlations between medial knee instability and the Lachman test/pivot shift test. However, the correlations were weak and other parameters were not significant. Lateral knee instability was greater in ACL-deficient knees than in uninjured knees. Lateral knee instability was associated with ACL-related instabilities as well as LCL damage on MRI, whereas MRI had low specificity to lateral knee instability. On the other hand, the association of medial knee instability on ACL-related instability was less than that of lateral knee instability. Level IV, case series with no comparison group. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  14. Preoperative Patellofemoral Chondromalacia is Not a Contraindication for Fixed-Bearing Medial Unicompartmental Knee Arthroplasty.

    PubMed

    Adams, Alexander J; Kazarian, Gregory S; Lonner, Jess H

    2017-06-01

    Patellofemoral chondromalacia (PFCM) has historically been considered a contraindication for unicompartmental knee arthroplasty (UKA), but there is limited data assessing PFCM's impact on the results of fixed-bearing UKA. Our objective was to assess the impact of medial patellar and/or medial trochlear PFCM on overall and patellofemoral-specific 2-year outcomes after fixed-bearing medial UKA. Intraoperative notes defined the presence and location of PFCM during fixed bearing medial UKA. Outcome measures included the New Knee Society Score (NKSS), Kneeling Ability Score (KAS) and Forgotten Joint Score (FJS-12). Thirty-one knees with PFCM (PFCM group), and 52 knees without PFCM (N-PFCM group) were included for analysis. Mann-Whitney U tests assessed the statistical significance of observed differences, and a Bonferroni correction was applied, adjusting threshold for significance to P = .005. At minimum follow-up of 2 years, no statistical differences were detected between the N-PFCM and PFCM groups in the postoperative NKSS (159 vs 157, P = .731), preoperative to postoperative NKSS change (P = .447), FJS-12 (70.5 vs 67.6, P = .471), or KAS (71% vs 65%, P = .217). Patients with isolated patellar chondromalacia (n = 13) demonstrated trends toward worse outcomes according to NKSS (147, P = .198), FJS-12 (58, P = .094), and KAS (46%, P = .018), but were statistically insignificant. No failures occurred in either group. Functional outcomes of fixed-bearing medial UKA are not adversely impacted by the presence of PFCM involving the medial patellar facet and/or medial or central trochlea. Further follow-up is needed to determine longer-term implications of fixed-bearing medial UKA in patients with PFCM. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Effects of a progressive aquatic resistance exercise program on the biochemical composition and morphology of cartilage in women with mild knee osteoarthritis: protocol for a randomised controlled trial

    PubMed Central

    2013-01-01

    Background Symptoms associated with osteoarthritis of the knee result in decreased function, loss of working capacity and extensive social and medical costs. There is a need to investigate and develop effective interventions to minimise the impact of and even prevent the progression of osteoarthritis. Aquatic exercise has been shown to be effective at reducing the impact of osteoarthritis. The purpose of this article is to describe the rationale, design and intervention of a study investigating the effect of an aquatic resistance exercise intervention on cartilage in postmenopausal women with mild knee osteoarthritis. Methods A minimum of 80 volunteers who meet the inclusion criteria will be recruited from the local population through newspaper advertisements. Following initial assessment volunteers will be randomised into two groups. The intervention group will participate in a progressive aquatic resistance exercise program of 1-hour duration 3 times a week for four months. The control group will be asked to maintain normal care during this period. Primary outcome measure for this study is the biochemical composition of knee cartilage measured using quantitative magnetic resonance imaging; T2 relaxation time and delayed gadolinium-enhanced magnetic resonance imaging techniques. In addition, knee cartilage morphology as regional cartilage thickness will be studied. Secondary outcomes include measures of body composition and bone traits using dual energy x-ray absorptiometry and peripheral quantitative computed tomography, pain, function using questionnaires and physical performance tests and quality of life. Measurements will be performed at baseline, after the 4-month intervention period and at one year follow up. Discussion This randomised controlled trial will investigate the effect a progressive aquatic resistance exercise program has on the biochemical composition of cartilage in post-menopausal women with mild knee osteoarthritis. This is the first study to investigate what impact aquatic exercise has on human articular cartilage. In addition it will investigate the effect aquatic exercise has on physical function, pain, bone and body composition and quality of life. The results of this study will help optimise the prescription of aquatic exercise to persons with mild knee osteoarthritis. Trial Registration ISRCTN65346593 PMID:23497162

  16. Effects of a progressive aquatic resistance exercise program on the biochemical composition and morphology of cartilage in women with mild knee osteoarthritis: protocol for a randomised controlled trial.

    PubMed

    Waller, Benjamin; Munukka, Matti; Multanen, Juhani; Rantalainen, Timo; Pöyhönen, Tapani; Nieminen, Miika T; Kiviranta, Ilkka; Kautiainen, Hannu; Selänne, Harri; Dekker, Joost; Sipilä, Sarianna; Kujala, Urho M; Häkkinen, Arja; Heinonen, Ari

    2013-03-07

    Symptoms associated with osteoarthritis of the knee result in decreased function, loss of working capacity and extensive social and medical costs. There is a need to investigate and develop effective interventions to minimise the impact of and even prevent the progression of osteoarthritis. Aquatic exercise has been shown to be effective at reducing the impact of osteoarthritis. The purpose of this article is to describe the rationale, design and intervention of a study investigating the effect of an aquatic resistance exercise intervention on cartilage in postmenopausal women with mild knee osteoarthritis. A minimum of 80 volunteers who meet the inclusion criteria will be recruited from the local population through newspaper advertisements. Following initial assessment volunteers will be randomised into two groups. The intervention group will participate in a progressive aquatic resistance exercise program of 1-hour duration 3 times a week for four months. The control group will be asked to maintain normal care during this period. Primary outcome measure for this study is the biochemical composition of knee cartilage measured using quantitative magnetic resonance imaging; T2 relaxation time and delayed gadolinium-enhanced magnetic resonance imaging techniques. In addition, knee cartilage morphology as regional cartilage thickness will be studied. Secondary outcomes include measures of body composition and bone traits using dual energy x-ray absorptiometry and peripheral quantitative computed tomography, pain, function using questionnaires and physical performance tests and quality of life. Measurements will be performed at baseline, after the 4-month intervention period and at one year follow up. This randomised controlled trial will investigate the effect a progressive aquatic resistance exercise program has on the biochemical composition of cartilage in post-menopausal women with mild knee osteoarthritis. This is the first study to investigate what impact aquatic exercise has on human articular cartilage. In addition it will investigate the effect aquatic exercise has on physical function, pain, bone and body composition and quality of life. The results of this study will help optimise the prescription of aquatic exercise to persons with mild knee osteoarthritis. ISRCTN65346593.

  17. The effect of thigh muscle activity on anterior knee laxity in the uninjured and anterior cruciate ligament-injured knee.

    PubMed

    Barcellona, Massimo G; Morrissey, Matthew C; Milligan, Peter; Amis, Andrew A

    2014-11-01

    The main purpose of this study was to describe the nature of the relationship between hamstring muscle activity and anterior knee laxity. This was a cross-sectional study. Anterior knee laxity was measured at 133N and manual maximal forces using the KT2000 knee arthrometer, in 8 ACL-injured and 13 uninjured individuals. Electromyographic activity of the lateral hamstrings was measured during laxity testing. Subjects contracted the hamstrings during anterior knee laxity testing at eight predetermined levels of maximal voluntary isometric contraction. Volitional contraction of the lateral hamstrings reduced anterior knee laxity logarithmically for both the 133N and manual maximal tests in both the ACL-injured and uninjured knees. A simple linear regression model, with the log of percentage of maximum lateral hamstrings activity as the sole predictor, explained approximately 70-80% of the variation in anterior knee laxity. Both ACL-injured and uninjured subjects reduced anterior knee laxity at the same rate with increases in muscle activity. However, initial lateral hamstrings muscle activity had a greater effect on percentage anterior knee laxity scores in the ACL-injured as compared to the uninjured knee. Lateral hamstrings activity reduces anterior knee laxity in a nonlinear manner, whereby the initial lower level of activation produces the greatest change in anterior knee laxity. Therefore, hamstrings muscle activity must be monitored during anterior knee laxity testing.

  18. 49 CFR 572.76 - Limbs assembly and test procedure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... between 1g and 2g. (ii) Place the dummy legs in a plane parallel to the dummy's midsagittal plane with the knee pivot center line perpendicular to the dummy's midsagittal plane, and with the feet flat on the... parallel to the midsagittal plane at the specified velocity. (5) Guide the test probe during impact so that...

  19. Conformity of behaviors among medical students: impact on performance of knee arthrocentesis in simulation.

    PubMed

    Beran, Tanya N; McLaughlin, Kevin; Al Ansari, Ahmed; Kassam, Aliya

    2013-10-01

    Although the development of collaborative relationships is considered a requirement for medical education, the functioning of these relationships may be impaired by a well-documented social-psychological phenomenon known as group conformity. The authors hypothesized that students would insert a needle into an incorrect location relative to the patella when performing a knee arthrocentesis if they believed that their peers had also inserted a needle in the same incorrect location. This was a randomized controlled study conducted in 2011 with 60 medical students (24 male; 40.0 %) who were randomly assigned to either using a knee model that had a skin with holes left by peers inserting needles in the wrong location, or a knee with no marks in the skin. Each student's aspiration site was measured with a fibreglass ruler to determine whether it was correctly located within the superior third, 1 cm medial to the patella. The researchers determined that students who used the marked skin were more likely to insert the needle in the incorrect location compared to those who used the clean skin (n = 31, 86.11 vs. n = 14, 58.33 %), Fisher's exact test (1) = 5.93, p < 0.05, Cramer's ϕ = 0.31. This study demonstrates incorrect performance of the knee arthrocentesis procedure in simulation when students use a damaged model, which may be due to conformity. It suggests that further research on the impact of conformity in medical education is warranted.

  20. Anterior cruciate ligament elasticity and force for flexion during the menstrual cycle

    PubMed Central

    Lee, Haneul; Petrofsky, Jerrold S.; Daher, Noha; Berk, Lee; Laymon, Michale; Khowailed, Iman Akef

    2013-01-01

    Background A high occurrence of knee injuries have been observed in women during the menstrual cycle (MC). As a result, numerous studies have been conducted regarding knee ligament elasticity during the MC. Some researchers believe that since estrogen receptor b exists in ligaments and tendons in the knee, estrogen may modulate towards a state of laxity. However, increased tissue temperature also observed during the MC can predispose ligament and tendon laxness. Therefore, the purpose of this study was to assess in women the relationship between Estradiol (E2) serum concentrations and tissue temperature during the MC and their combined effect on knee laxity. Material/Methods Ten non-athletic young healthy females, 18 to 30 years of age participated in the study. E2 serum concentrations, anterior cruciate ligament (ACL) elasticity, and force to flex the knee (FFK), knee flexion-extension hysteresis (KFEH) were assessed both at ambient temperature (22°C) and after 38°C warming. Testing was performed multiple times during the participant’s MC, for one full MC. Results ACL elasticity was significantly higher (P<0.01) and FFK and KFEH were significantly lower (p<0.05) during ovulation when E2 levels were highest. ACL elasticity was still higher during ovulation after warming to 38°C. But, the effects of MC on FFK and KFEH were reduced by tissue warming. Conclusions ACL elasticity, FFK, and KFEH was affected not only by E2 but also tissue temperature. However, E2 had more impact on ACL elasticity while tissue temperature had more impact on FFK and KFEH at 38°C warming. PMID:24287619

  1. Impact of Balance Confidence on Daily Living Activities of Older People with Knee Osteoarthritis with Regard to Balance, Physical Function, Pain, and Quality of Life - A Preliminary Report.

    PubMed

    Bobić Lucić, Lana; Grazio, Simeon

    2018-01-01

    The objective of this study was to explore the impact of balance confidence on different activities of daily living (ADL) in older people with knee osteoarthritis (OA). Forty-seven consecutive participants with knee OA were included in this cross-sectional study. They were divided according to the results of the Activities-specific Balance Confidence (ABC) Scale into a group with a low level of confidence in physical functioning (ABC < 50, n = 22) and a group with moderate and high levels of confidence (ABC ≥ 50, n = 25). In the ABC < 50 group, the effect of pain on ADL, the physician's global assessment of the disease, and the Western Ontario and McMaster Universities Osteoarthritis Index scores were significantly higher, while quality of life (Short form-36) was lower compared to the ABC ≥ 50 group. No significant difference was found between the two groups regarding the static and dynamic balance measurements. Older people with knee OA who were less confident in their daily physical activities had more physical difficulties and a greater effect of pain on ADL, lower quality of life, and a higher physician's global assessment, but no differences were obtained in balance tests. In people with knee OA, decreased balance confidence is associated with more physical difficulties, an increased effect of pain on ADL, and lower quality of life. An improved awareness of decreased balance confidence may lead to more effective management of older people with knee OA by improving their mobility and QOL through rehabilitation. Furthermore, future research in that direction is warranted.

  2. Effect of knee osteoarthritis on the perception of quality of life in Venezuelan patients.

    PubMed

    Chacón, José G; González, Nancy E; Véliz, Aleida; Losada, Benito R; Paul, Hernando; Santiago, Luís G; Antúnez, Ana; Finol, Yelitza; González, María E; Granados, Isabel; Maldonado, Irama; Maldonado, Teolinda; Marín, Francisco; Zambrano, Gisela; Rodríguez, Martín A

    2004-06-15

    To measure the perception of quality of life in Venezuelan patients with knee osteoarthritis and to identify those variables that may influence it. A multicenter, cross-sectional study of 126 mestizo patients with knee osteoarthritis recruited from 8 rheumatology centers in Venezuela. We used a Spanish-translated version of the Arthritis Impact Measurement Scales (AIMS), as adapted in Venezuela. One-way analysis of variance was used to compare the AIMS mean total score among subgroups of knee pain, anatomic stage, and socioeconomic status (SES); a post-hoc test was performed to identify significant intragroup differences. Pearson's correlation coefficient was used to examine correlations between age, body mass index (BMI), disease duration, knee pain, and AIMS score. Associations between radiologic stage, SES, and AIMS scores were examined using Spearman's rank correlation. Multiple regression analysis was used to estimate predictor factors of AIMS scores. A significant correlation was found between total AIMS scores and knee pain, age, and socioeconomic status, but not with BMI, disease duration, or anatomic stage. Patients with severe knee pain differed from those with mild and moderate pain, and the highest AIMS mean total score was seen in patients within the severe knee pain subset. Patients in the highest socioeconomic levels differed from those within lowest categories. Patients classified as being at the levels of relative and critical poverty showed the highest AIMS scores. Multiple regression analysis showed that knee pain was the only variable that exerted an independent effect on the quality of life in our patients. The perception of quality of life is negatively affected by increasing levels of joint pain, old age, and low socioeconomic status in Venezuelan patients with knee osteoarthritis. Our study supports the need for an early and vigorous approach to treat pain in this group of patients.

  3. Dynamic knee valgus alignment influences impact attenuation in the lower extremity during the deceleration phase of a single-leg landing.

    PubMed

    Tamura, Akihiro; Akasaka, Kiyokazu; Otsudo, Takahiro; Shiozawa, Jyunya; Toda, Yuka; Yamada, Kaori

    2017-01-01

    Dynamic knee valgus during landings is associated with an increased risk of non-contact anterior cruciate ligament (ACL) injury. In addition, the impact on the body during landings must be attenuated in the lower extremity joints. The purpose of this study was to investigate landing biomechanics during landing with dynamic knee valgus by measuring the vertical ground reaction force (vGRF) and angular impulses in the lower extremity during a single-leg landing. The study included 34 female college students, who performed the single-leg drop vertical jump. Lower extremity kinetic and kinematic data were obtained from a 3D motion analysis system. Participants were divided into valgus (N = 19) and varus (N = 15) groups according to the knee angular displacement during landings. The vGRF and angular impulses of the hip, knee, and ankle were calculated by integrating the vGRF-time curve and each joint's moment-time curve. vGRF impulses did not differ between two groups. Hip angular impulse in the valgus group was significantly smaller than that in the varus group (0.019 ± 0.033 vs. 0.067 ± 0.029 Nms/kgm, p<0.01), whereas knee angular impulse was significantly greater (0.093 ± 0.032 vs. 0.045 ± 0.040 Nms/kgm, p<0.01). There was no difference in ankle angular impulse between the groups. Our results indicate that dynamic knee valgus increases the impact the knee joint needs to attenuate during landing; conversely, the knee varus participants were able to absorb more of the landing impact with the hip joint.

  4. Impact of associated injuries in the Floating knee: A retrospective study

    PubMed Central

    Rethnam, Ulfin; Yesupalan, Rajam S; Nair, Rajagopalan

    2009-01-01

    Background Floating knee injuries are usually associated with other significant injuries. Do these injuries have implications on the management of the floating knee and the final outcome of patients? Our study aims to assess the implications of associated injuries in the management and final outcome of floating knee. Methods 29 patients with floating knees were assessed in our institution. A retrospective analysis of medical records and radiographs were done and all associated injuries were identified. The impact of associated injuries on delay in initial surgical management, delay in rehabilitation & final outcome of the floating knee were assessed. Results 38 associated injuries were noted. 7 were associated with ipsilateral knee injuries. Lower limb injuries were most commonly associated with the floating knee. Patients with some associated injuries had a delay in surgical management and others a delay in post-operative rehabilitation. Knee ligament and vascular injuries were associated with poor outcome. Conclusion The associated injuries were quite frequent with the floating knee. Some of the associated injuries caused a delay in surgical management and post-operative rehabilitation. In assessment of the final outcome, patients with associated knee and vascular injuries had a poor prognosis. Majority of the patients with associated injuries had a good or excellent outcome. PMID:19144197

  5. Knee osteoarthritis, degenerative meniscal lesion and osteonecrosis of the knee: Can a simple gait test direct us to a better clinical diagnosis.

    PubMed

    Debi, R; Elbaz, A; Mor, A; Kahn, G; Peskin, B; Beer, Y; Agar, G; Morag, G; Segal, G

    2017-06-01

    The purpose of the current study was to compare the gait patterns in patients with three differing knee pathologies - knee osteoarthritis (OA), degenerative meniscal lesion (DML) and spontaneous osteonecrosis of the knee (SONK) and a group of healthy controls. A simple gait test will detect differences between different knee pathologies. Forty-seven patients with bilateral knee OA, 47 patients with DML, 28 patients with SONK and 27 healthy controls were included in this analysis. Patients underwent a spatiotemporal gait assessment and were asked to complete the Western Ontario and McMaster University (WOMAC) Index and the Short-Form (SF)-36 Health Survey. ANOVA tests, followed by Bonferroni multiple comparison tests and the Chi 2 tests were performed for continuous and categorical variables, respectively. Significant differences were found for all gait measures and clinical questionnaires between healthy controls and all knee conditions. Patients with SONK differed from patients with bilateral knee OA and DML in all gait measures and clinical questionnaires, except for WOMAC subscales. There were no significant differences between patients with bilateral knee OA and patients with DML. Symmetry was also examined and revealed asymmetry in some gait parameters in patients with SONK and DML. Based on the differences in gait parameters that were found in the current study, adding an objective functional spatiotemporal gait test may assist in the diagnostic process of knee pathologies. Case Control study Level III. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  6. Quadriceps Strength in Patients With Isolated Cartilage Defects of the Knee: Results of Isokinetic Strength Measurements and Their Correlation With Clinical and Functional Results

    PubMed Central

    Hirschmüller, Anja; Andres, Tasja; Schoch, Wolfgang; Baur, Heiner; Konstantinidis, Lukas; Südkamp, Norbert P.; Niemeyer, Philipp

    2017-01-01

    Background: Recent studies have found a significant deficit of maximum quadriceps strength after autologous chondrocyte implantation (ACI) of the knee. However, it is unclear whether muscular strength deficits in patients with cartilage damage exist prior to operative treatment. Purpose: To isokinetically test maximum quadriceps muscle strength and quantify the impact of possible strength deficits on functional and clinical test results. Study Design: Cross-sectional study; Level of evidence, 3. Methods: To identify clinically relevant muscular strength deficits, 24 patients (5 females, 19 males; mean age, 34.5 years; body mass index, 25.9 kg/m2) with isolated cartilage defects (mean onset, 5.05 years; SD, 7.8 years) in the knee joint underwent isokinetic strength measurements. Maximal quadriceps strength was recorded in 3 different testing modes: pure concentric contraction (flexors and extensors alternating work; con1), concentric-eccentric (only the extensors work concentrically and eccentrically; con2), and eccentric contraction in the alternating mode (ecc). Results were compared for functional performance (single-leg hop test), pain scales (visual analog scale [VAS], numeric rating scale [NRS]), self-reported questionnaires (International Knee Documentation Committee [IKDC], Knee Injury and Osteoarthritis Outcome Scale [KOOS]), and defect size (cm2). Results: Compared with the uninjured leg, significantly lower quadriceps strength was detected in the injured leg in all isokinetic working modes (con1 difference, 27.76 N·m [SD 17.47; P = .003]; con2 difference, 21.45 N·m [SD, 18.45; P =.025]; ecc difference, 29.48 N·m [SD, 21.51; P = .001]), with the largest deficits found for eccentric muscle performance. Moderate negative correlations were observed for the subjective pain scales NRS and VAS. The results of the IKDC and KOOS questionnaires showed low, nonsignificant correlations with findings in the isokinetic measurement. Moreover, defect sizes (mean, 3.13 cm2) were of no importance regarding the prediction of the strength deficit. The quadriceps strength deficit between the injured and the uninjured leg was best predicted by the results of the single-leg hop test. Conclusion: Patients with isolated cartilage defects of the knee joint have significant deficits in quadriceps muscle strength of the injured leg compared with the uninjured leg. The single-leg hop test may be used to predict quadriceps strength deficits. Future research should address whether preoperative strength training in patients with cartilage defects of the knee could be effective and should be taken into consideration in addition to surgical treatment. PMID:28596973

  7. Dual-task and anticipation impact lower limb biomechanics during a single-leg cut with body borne load.

    PubMed

    Seymore, Kayla D; Cameron, Sarah E; Kaplan, Jonathan T; Ramsay, John W; Brown, Tyler N

    2017-12-08

    This study quantified how a dual cognitive task impacts lower limb biomechanics during anticipated and unanticipated single-leg cuts with body borne load. Twenty-four males performed anticipated and unanticipated cuts with and without a dual cognitive task with three load conditions: no load (∼6 kg), medium load (15% of BW), and heavy load (30% of BW). Lower limb biomechanics were submitted to a repeated measures linear mixed model to test the main and interaction effects of load, anticipation, and dual task. With body borne load, participants increased peak stance (PS) hip flexion (p = .004) and hip internal rotation (p = .001) angle, and PS hip flexion (p = .001) and internal rotation (p = .018), and knee flexion (p = .016) and abduction (p = .001) moments. With the dual task, participants decreased PS knee flexion angle (p < .001) and hip flexion moment (p = .027), and increased PS knee external rotation angle (p = .034). During the unanticipated cut, participants increased PS hip (p = .040) and knee flexion angle (p < .001), and decreased PS hip adduction (p = .001), and knee abduction (p = .005) and external rotation (p = .026) moments. Adding body borne load produces lower limb biomechanical adaptations thought to increase risk of musculoskeletal injury, but neither anticipation nor dual task exaggerated those biomechanical adaptations. With a dual task, participants adopted biomechanics known to increase injury risk; whereas, participants used lower limb biomechanics thought to decrease injury risk during unanticipated cuts. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Quality of Life in Patients with Knee Osteoarthritis: A Commentary on Nonsurgical and Surgical Treatments

    PubMed Central

    Farr II, Jack; Miller, Larry E.; Block, Jon E.

    2013-01-01

    Knee osteoarthritis (OA) has a significant negative impact on health-related quality of life (HRQoL). Identification of therapies that improve HRQoL in patients with knee OA may mitigate the clinical, economic, and social burden of this disease. The purpose of this commentary is to report the impact of knee OA on HRQoL, describe the change in HRQoL attributable to common knee OA interventions, and summarize findings from clinical trials of a promising therapy. Nonsurgical therapies do not reliably modify HRQoL in knee OA patients given their general inability to alleviate physical manifestations of OA. Surgical knee OA interventions generally result in good to excellent patient outcomes. However, there are significant barriers to considering surgery, which limits clinical utility. Therapies that most effectively control OA-related pain with a low risk: benefit ratio will likely have the greatest benefit on HRQoL with greater rates of patient adoption. Initial clinical trial findings suggest that less invasive joint unloading implants hold promise in bridging the therapeutic gap between nonsurgical and surgical treatments for the knee OA patient. PMID:24285987

  9. Biomechanical and anatomical assessment after knee hyperextension injury.

    PubMed

    Fornalski, Stefan; McGarry, Michelle H; Csintalan, Rick P; Fithian, Donald C; Lee, Thay Q

    2008-01-01

    Knee hyperextension can be a serious and disabling injury in both the athletic and general patient population. Understanding the pathoanatomy and pathomechanics is critical for accurate surgical soft tissue reconstructions. To quantify the effects of knee hyperextension injury on knee laxity in a human cadaveric model and to qualitatively assess the anatomical injury pattern through surgical dissection. Descriptive laboratory study. Six fresh-frozen cadaveric knees were rigidly mounted on a custom knee testing system that simulates clinical laxity tests. The knee laxity measurements consisted of anterior-posterior laxity, internal-external rotational laxity, and varus-valgus laxity using a custom testing setup and a Microscribe 3DLX system. The laxity data were collected at both 30 degrees and 90 degrees of knee flexion for the intact specimens and then after 15 degrees and 30 degrees hyperextension injury. After biomechanical assessment, a detailed dissection was performed to document the injured structures in the knee. Repeated-measures analysis of variance with a Tukey post hoc test (P < .05) was used for statistical comparison. The results from this study suggest progressive damage to translational and rotational knee soft-tissue restraints with increasing knee hyperextension. Knee hyperextension to 30 degrees caused the most significant increase in anterior-posterior and rotational laxity. Anatomical dissections showed a general injury pattern to the posterolateral corner, partial femoral anterior cruciate ligament avulsion in 4 of 6 specimens, and no gross posterior cruciate ligament injuries. Injuries to the posterolateral corner of the knee can result from isolated knee hyperextension. The clinician should be aware of the potential for posterolateral corner injuries with isolated knee hyperextension. This will allow early surgical planning and primary surgical repair.

  10. Effects of physiotherapy treatment on knee osteoarthritis gait data using principal component analysis.

    PubMed

    Gaudreault, Nathaly; Mezghani, Neila; Turcot, Katia; Hagemeister, Nicola; Boivin, Karine; de Guise, Jacques A

    2011-03-01

    Interpreting gait data is challenging due to intersubject variability observed in the gait pattern of both normal and pathological populations. The objective of this study was to investigate the impact of using principal component analysis for grouping knee osteoarthritis (OA) patients' gait data in more homogeneous groups when studying the effect of a physiotherapy treatment. Three-dimensional (3D) knee kinematic and kinetic data were recorded during the gait of 29 participants diagnosed with knee OA before and after they received 12 weeks of physiotherapy treatment. Principal component analysis was applied to extract groups of knee flexion/extension, adduction/abduction and internal/external rotation angle and moment data. The treatment's effect on parameters of interest was assessed using paired t-tests performed before and after grouping the knee kinematic data. Increased quadriceps and hamstring strength was observed following treatment (P<0.05). Except for the knee flexion/extension angle, two different groups (G(1) and G(2)) were extracted from the angle and moment data. When pre- and post-treatment analyses were performed considering the groups, participants exhibiting a G(2) knee moment pattern demonstrated a greater first peak flexion moment, lower adduction moment impulse and smaller rotation angle range post-treatment (P<0.05). When pre- and post-treatment comparisons were performed without grouping, the data showed no treatment effect. The results of the present study suggest that the effect of physiotherapy on gait mechanics of knee osteoarthritis patients may be masked or underestimated if kinematic data are not separated into more homogeneous groups when performing pre- and post-treatment comparisons. Copyright © 2010 Elsevier Ltd. All rights reserved.

  11. The influence of applied internal and external rotation on the pivot shift phenomenon.

    PubMed

    Kopf, Sebastian; Musahl, Volker; Perka, Carsten; Kauert, Ralf; Hoburg, Arnd; Becker, Roland

    2017-04-01

    The pivot shift test is performed in different techniques and the rotation of the tibia seems to have a significant impact on the amount of the pivot shift phenomenon. It has been hypothesised that external rotation will increase the phenomenon due to less tension at the iliotibial band in knee extension. Twenty-four patients with unilateral anterior cruciate ligament insufficiency were included prospectively. The pivot shift test was performed bilaterally in internal and external tibial rotation under general anaesthesia. Knee motion was captured using a femoral and a tibial inertial sensor. The difference between positive and negative peak values in Euclidean norm of acceleration was calculated to evaluate the amount of the pivot shift phenomenon. The pivot shift phenomenon was significantly increased in patients with ACL insufficiency when the test was performed in external [mean 5.2 ms - 2 (95% CI 4.3-6.0)] compared to internal tibial rotation [mean 4.4 ms - 2 (95% CI 3.5-5.4)] (p = 0.002). In healthy, contralateral knees did not show any difference between external [mean 4.0 ms - 2 (95% CI 3.3-4.7)] and internal tibial rotation [mean 4.0 ms - 2 (95% CI 3.4-4.6)] (ns). The pivot shift phenomenon was increased with external rotation in ACL-insufficient knees, and therefore, one should perform the pivot shift test, rather, in external rotation to easily evoke the, sometimes difficult to detect, pivot shift phenomenon. I (diagnostic study).

  12. [The impact of dynamic platform exercises on knee joint muscle strength in patients with gonarthrosis treated with microfracture method].

    PubMed

    Klupiński, Kamil; Krochmalski, Jakub; Woldańska-Okońska, Marta

    2017-06-23

    Osteoarthritis is the most common joint disease. Gonarthrosis is one of the most serious diseases the highly developed modern medicine must face. The number of patients suffering from joint pain and progressive disability is growing, especially in economically developed countries. Over the years, the disease has been considered merely as a symptom of aging and the effect of "wear and tear" of the cartilage. At present it is known that the degenerative joint disease is of chronic and progressive nature and its pathogenesis is complex. The aim of the study was to determine the impact of dynamic platform exercises on knee joint muscle strength in patients with gonarthrosis treated with microfracture method. The study included 120 patients of both sexes, aged 40 to 65 years, height range1.60-1.90 m., weight 50- 100 kg. Patients were divided into two groups. Group I of 60 patients after knee arthroscopy (with performed microfractures on the articular cartilage) who were subjected to physiotherapy with the use of dynamometric platform and to isometric and dynamic exercises of muscles surrounding the knee joint. Group II (control) of 60 patients after knee arthroscopy (with performed microfractures on the articular cartilage), who were subjected only to isometric and dynamic exercises of muscles surrounding the knee joint. The patients underwent rehabilitation according to the same rehabilitation program suggested by the Medical Magnus Clinic in Lodz, which consisted in performing daily exercises in open and closed kinetic chains. All Group I and II patients were examined three times: before the start of the rehabilitation, after 4th week of rehabilitation (on the average 20 days of the procedures) and 3 months afterwards. The clinical examination included the measurement of muscle strength using Lovett test. It has been demonstrated that the introduction of modern highly specialized physiotherapy contributes to the improvement of the outcome and to the shortening of the treatment duration. A significant improvement was observed in all the examined patients at all stages of rehabilitation in relation to the baseline values. The conducted modern physiotherapy has a significant effect on the condition of patients after surgery. Different exercises on dynamometric platform combined with static and dynamic exercises exert a positive impact on the strengthening of muscles surrounding the knee joint, which in time perspective results in better quality of life of the patients.

  13. Examining Ankle-Joint Laxity Using 2 Knee Positions and With Simulated Muscle Guarding

    PubMed Central

    Hanlon, Shawn; Caccese, Jaclyn; Knight, Christopher A.; Swanik, Charles “Buz”; Kaminski, Thomas W.

    2016-01-01

    Context:  Several factors affect the reliability of the anterior drawer and talar tilt tests, including the individual clinician's experience and skill, ankle and knee positioning, and muscle guarding. Objectives:  To compare gastrocnemius activity during the measurement of ankle-complex motion at different knee positions, and secondarily, to compare ankle-complex motion during a simulated trial of muscle guarding. Design:  Cross-sectional study. Setting:  Research laboratory. Patients or Other Participants:  Thirty-three participants aged 20.2 ± 1.7 years were tested. Intervention(s):  The ankle was loaded under 2 test conditions (relaxed, simulated muscle guarding) at 2 knee positions (0°, 90° of flexion) while gastrocnemius electromyography (EMG) activity was recorded. Main Outcome Measure(s):  Anterior displacement (mm), inversion-eversion motion (°), and peak EMG amplitude values of the gastrocnemius (μV). Results:  Anterior displacement did not differ between the positions of 0° and 90° of knee flexion (P = .193). Inversion-eversion motion was greater at 0° of knee flexion compared with 90° (P < .001). Additionally, peak EMG amplitude of the gastrocnemius was not different between 0° and 90° of knee flexion during anterior displacement (P = .101). As expected, the simulated muscle-guarding trial reduced anterior displacement compared with the relaxed condition (0° of knee flexion, P = .008; 90° of knee flexion, P = .016) and reduced inversion-eversion motion (0° of knee flexion, P = .03; 90° of knee flexion, P < .001). Conclusions:  In a relaxed state, the gastrocnemius muscle did not appear to affect anterior ankle laxity at the 2 most common knee positions for anterior drawer testing; however, talar tilt testing may be best performed with the knee in 0° of knee flexion. Finally, our outcomes from the simulated muscle-guarding condition suggest that clinicians should use caution and be aware of reduced perceived laxity when performing these clinical examination techniques immediately postinjury. PMID:26881870

  14. Examining Ankle-Joint Laxity Using 2 Knee Positions and With Simulated Muscle Guarding.

    PubMed

    Hanlon, Shawn; Caccese, Jaclyn; Knight, Christopher A; Swanik, Charles Buz; Kaminski, Thomas W

    2016-02-01

    Several factors affect the reliability of the anterior drawer and talar tilt tests, including the individual clinician's experience and skill, ankle and knee positioning, and muscle guarding. To compare gastrocnemius activity during the measurement of ankle-complex motion at different knee positions, and secondarily, to compare ankle-complex motion during a simulated trial of muscle guarding. Cross-sectional study. Research laboratory. Thirty-three participants aged 20.2 ± 1.7 years were tested. The ankle was loaded under 2 test conditions (relaxed, simulated muscle guarding) at 2 knee positions (0°, 90° of flexion) while gastrocnemius electromyography (EMG) activity was recorded. Anterior displacement (mm), inversion-eversion motion (°), and peak EMG amplitude values of the gastrocnemius (μV). Anterior displacement did not differ between the positions of 0° and 90° of knee flexion (P = .193). Inversion-eversion motion was greater at 0° of knee flexion compared with 90° (P < .001). Additionally, peak EMG amplitude of the gastrocnemius was not different between 0° and 90° of knee flexion during anterior displacement (P = .101). As expected, the simulated muscle-guarding trial reduced anterior displacement compared with the relaxed condition (0° of knee flexion, P = .008; 90° of knee flexion, P = .016) and reduced inversion-eversion motion (0° of knee flexion, P = .03; 90° of knee flexion, P < .001). In a relaxed state, the gastrocnemius muscle did not appear to affect anterior ankle laxity at the 2 most common knee positions for anterior drawer testing; however, talar tilt testing may be best performed with the knee in 0° of knee flexion. Finally, our outcomes from the simulated muscle-guarding condition suggest that clinicians should use caution and be aware of reduced perceived laxity when performing these clinical examination techniques immediately postinjury.

  15. Angular-velocity control approach for stance-control orthoses.

    PubMed

    Lemaire, Edward D; Goudreau, Louis; Yakimovich, Terris; Kofman, Jonathan

    2009-10-01

    Currently, stance-control knee orthoses require external control mechanisms to control knee flexion during stance and allow free knee motion during the swing phase of gait. A new angular-velocity control approach that uses a rotary-hydraulic device to resist knee flexion when the knee angular velocity passes a preset threshold is presented. This angular-velocity approach for orthotic stance control is based on the premise that knee-flexion angular velocity during a knee-collapse event, such as a stumble or fall, is greater than that during walking. The new hydraulic knee-flexion control device does not require an external control mechanism to switch from free motion to stance control mode. Functional test results demonstrated that the hydraulic angular-velocity activated knee joint provided free knee motion during walking, engaged upon knee collapse, and supported body weight while the end-user recovered to a safe body position. The joint was tested to 51.6 Nm in single loading tests and passed 200,000 repeated loading cycles with a peak load of 88 Nm per cycle. The hydraulic, angular velocity activation approach has potential to improve safety and security for people with lower extremity weakness or when recovering from joint trauma.

  16. Effects of Step Length, Age, and Fall History on Hip and Knee Kinetics and Knee Co-contraction during the Maximum Step Length Test

    PubMed Central

    Schulz, Brian W.; Jongprasithporn, Manutchanok; Hart-Hughes, Stephanie J.; Bulat, Tatjana

    2017-01-01

    Background Maximum step length is a brief clinical test involving stepping out and back as far as possible with the arms folded across the chest. This test has been shown to predict fall risk, but the biomechanics of this test are not fully understood. Knee and hip kinetics (moments and powers) are greater for longer steps and for younger subjects, but younger subjects also step farther. Methods To separate effects of step length, age, and fall history on joint kinetics; 14 healthy younger, 14 older non-fallers, and 11 older fallers (27(5), 72(5), 75(6) years respectively) all stepped to the same relative target distances of 20-80% of their height. Knee and hip kinetics and knee co-contraction were calculated. Findings Hip and knee kinetics and knee co-contraction all increased with step length, but older non-fallers and fallers utilized greater stepping hip and less stepping knee extensor kinetics. Fallers had greater stepping knee co-contraction than non-fallers. Stance knee co-contraction of non-fallers was similar to young for shorter steps and similar to fallers for longer steps. Interpretation Age had minimal effects and fall history had no effects on joint kinetics of steps to similar distances. Effects of age and fall history on knee co-contraction may contribute to age-related kinetic differences and shorter maximal step lengths of older non-fallers and fallers, but step length correlated with every variable tested. Thus, declines in maximum step length could indicate declines in hip and knee extensor kinetics and impaired performance on similar tasks like recovering from a trip. PMID:23978310

  17. Above-knee prosthesis design based on fatigue life using finite element method and design of experiment.

    PubMed

    Phanphet, Suwattanarwong; Dechjarern, Surangsee; Jomjanyong, Sermkiat

    2017-05-01

    The main objective of this work is to improve the standard of the existing design of knee prosthesis developed by Thailand's Prostheses Foundation of Her Royal Highness The Princess Mother. The experimental structural tests, based on the ISO 10328, of the existing design showed that a few components failed due to fatigue under normal cyclic loading below the required number of cycles. The finite element (FE) simulations of structural tests on the knee prosthesis were carried out. Fatigue life predictions of knee component materials were modeled based on the Morrow's approach. The fatigue life prediction based on the FE model result was validated with the corresponding structural test and the results agreed well. The new designs of the failed components were studied using the design of experimental approach and finite element analysis of the ISO 10328 structural test of knee prostheses under two separated loading cases. Under ultimate loading, knee prosthesis peak von Mises stress must be less than the yield strength of knee component's material and the total knee deflection must be lower than 2.5mm. The fatigue life prediction of all knee components must be higher than 3,000,000 cycles under normal cyclic loading. The design parameters are the thickness of joint bars, the diameter of lower connector and the thickness of absorber-stopper. The optimized knee prosthesis design meeting all the requirements was recommended. Experimental ISO 10328 structural test of the fabricated knee prosthesis based on the optimized design confirmed the finite element prediction. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  18. Effect of subjective knee-joint pain on the laterality of knee extension strength and gait in elderly women.

    PubMed

    Sugiura, Hiroki; Demura, Shinichi

    2012-01-01

    This study aimed to examine the effect of subjective knee-joint pain on the laterality of knee extension strength and gait in elderly women. The subjects were 144 elderly women (62-94 years old; mean age 76.2±6.0 years; ±S.D.) who were divided into the following groups: 81 persons without knee-pain (no knee-pain group), 39 persons with the subjective pain in right or left knee (single knee-pain group), and 24 persons with the subjective pain in both knees (double knee-pain group). The subjects took a knee extension strength test and a 12 m maximum effort walk test. Knee extension strength, stance time, swing time, stride length, step length and swing speed were selected as parameters. A significant laterality was found in knee extension strength only in the one knee-pain group. The laterality of gait parameters was not found in all groups. In conclusion, elderly women who can perform daily living activity independently, even though having subjective pain in either knee or laterality in knee extension strength exertion show little laterality of gait during short distance walking. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  19. Mechanical and biomechanical analysis of a linear piston design for angular-velocity-based orthotic control.

    PubMed

    Lemaire, Edward D; Samadi, Reza; Goudreau, Louis; Kofman, Jonathan

    2013-01-01

    A linear piston hydraulic angular-velocity-based control knee joint was designed for people with knee-extensor weakness to engage knee-flexion resistance when knee-flexion angular velocity reaches a preset threshold, such as during a stumble, but to otherwise allow free knee motion. During mechanical testing at the lowest angular-velocity threshold, the device engaged within 2 degrees knee flexion and resisted moment loads of over 150 Nm. The device completed 400,000 loading cycles without mechanical failure or wear that would affect function. Gait patterns of nondisabled participants were similar to normal at walking speeds that produced below-threshold knee angular velocities. Fast walking speeds, employed purposely to attain the angular-velocity threshold and cause knee-flexion resistance, reduced maximum knee flexion by approximately 25 degrees but did not lead to unsafe gait patterns in foot ground clearance during swing. In knee collapse tests, the device successfully engaged knee-flexion resistance and stopped knee flexion with peak knee moments of up to 235.6 Nm. The outcomes from this study support the potential for the linear piston hydraulic knee joint in knee and knee-ankle-foot orthoses for people with lower-limb weakness.

  20. Single-Leg Hop Test Performance and Isokinetic Knee Strength After Anterior Cruciate Ligament Reconstruction in Athletes

    PubMed Central

    Sueyoshi, Ted; Nakahata, Akihiro; Emoto, Gen; Yuasa, Tomoki

    2017-01-01

    Background: Isokinetic strength and hop tests are commonly used to assess athletes’ readiness to return to sport after knee surgery. Purpose/Hypothesis: The purpose of this study was to investigate the results of single-leg hop and isokinetic knee strength testing in athletes who underwent anterior cruciate ligament reconstruction (ACLR) upon returning to sport participation as well as to study the correlation between these 2 test batteries. The secondary purpose was to compare the test results by graft type (patellar tendon or hamstring). It was hypothesized that there would be no statistically significant limb difference in either isokinetic knee strength or single-leg hop tests, that there would be a moderate to strong correlation between the 2 test batteries, and that there would be no significant difference between graft types. Study Design: Cross-sectional study; Level of evidence, 3. Methods: Twenty-nine high school and collegiate athletes who underwent ACLR participated in this study. At the time of return to full sport participation, a series of hop tests and knee extension/flexion isokinetic strength measurements were conducted. The results were analyzed using analysis of variance and Pearson correlation (r). Results: The timed 6-m hop test was the only hop test that showed a significant difference between the involved and uninvolved limbs (2.3 and 2.2 seconds, respectively; P = .02). A significant difference between limbs in knee strength was found for flexion peak torque/body weight at 180 deg/s (P = .03), flexion total work/body weight at 180 deg/s (P = .04), and flexion peak torque/body weight at 300 deg/s (P = .03). The strongest correlation between the hop tests and knee strength was found between the total distance of the hop tests and flexion total work/body weight at 300 deg/s (r = 0.69) and between the timed 6-m hop test and flexion peak torque/body weight at 300 deg/s (r = –0.54). There was no statistically significant difference in hop test performance or isokinetic knee strength between graft types. Conclusion: The single-leg hop tests and isokinetic strength measurements were both useful for a bilateral comparison of knee functional performance and strength. Knee flexion strength deficits and flexion-to-extension ratios seemed to be correlated with single-leg hop test performance. There was no difference in postoperative hop test performance or knee strength according to graft type. PMID:29164167

  1. Knee dislocations with vascular injury: outcomes in the Lower Extremity Assessment Project (LEAP) Study.

    PubMed

    Patterson, Brendan M; Agel, Julie; Swiontkowski, Marc F; Mackenzie, Ellen J; Bosse, Michael J

    2007-10-01

    The purpose of this study is to report the clinical and functional results of a cohort of patients with knee dislocations associated with vascular injury. Patients with knee dislocation and associated vascular injury were prospectively assessed for outcome of severe lower extremity trauma during 2 years. The Sickness Impact Profile was used to assess the functional recovery of the patient. Surgeon and therapist assessments documented clinical metrics and treatment, including salvage or amputation, neurologic recovery, knee stability, and knee motion. Eighteen patients sustained a knee dislocation and an associated popliteal artery injury. Seven patients were found to have an additional vascular injury. All patients underwent repair of the vascular injury. At the time of final follow-up, 14 knees were successfully salvaged and four required amputation (1 below knee amputation, 2 through knee amputation, and 1 above knee amputation). Eighteen patients had at least a popliteal injury and underwent repair of the vascular injury. The patients with a limb-threatening knee dislocation that was successfully reconstructed had Sickness Impact Profile scores of 20.12 at 3 months, 13.18 at 6 months, 12.08 at 1 year, and 7.0 at 2 years after injury. Patients who sustain a limb-threatening knee dislocation have a moderate to high level of disability 2 years after injury. Nearly one in five patients who present to a Level I trauma center with a dysvascular limb associated with a knee dislocation will require amputation. Prolonged warm ischemia time was associated with a high rate of amputation. Patients who sustain vascular injuries associated with a knee dislocation need immediate transport to a trauma hospital, rapid assessment and diagnosis at presentation, and revascularization. Patients with these injuries can be effectively treated without angiography before surgery.

  2. The Impact of Osseous Malalignment and Realignment Procedures in Knee Ligament Surgery: A Systematic Review of the Clinical Evidence.

    PubMed

    Tischer, Thomas; Paul, Jochen; Pape, Dietrich; Hirschmann, Michael T; Imhoff, Andreas B; Hinterwimmer, Stefan; Feucht, Matthias J

    2017-03-01

    Failure rates of knee ligament surgery may be high, and the impact of osseous alignment on surgical outcome remains controversial. Basic science studies have demonstrated that osseous malalignment can negatively affect ligament strain and that realignment procedures may improve knee joint stability. The purpose of this review was to summarize the clinical evidence concerning the impact of osseous malalignment and realignment procedures in knee ligament surgery. The hypotheses were that lower extremity malalignment would be an important contributor to knee ligament surgery failure and that realignment surgery would contribute to increased knee stability and improved outcome in select cases. Systematic review; Level of evidence, 4. According to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines, a systematic electronic search of the PubMed database was performed in November 2015 to identify clinical studies investigating (A) the influence of osseous alignment on postoperative stability and/or failure rates after knee ligament surgery and (B) the impact of osseous realignment procedures in unstable knees with or without additional knee ligament surgery on postoperative knee function and stability. Methodological quality of the studies was assessed using the Oxford Centre for Evidence-Based Medicine Levels of Evidence and the Coleman Methodological Score (CMS). Of the 1466 potentially relevant articles, 28 studies fulfilled the inclusion and exclusion criteria. Average study quality was poor (CMS, 40). For part A, studies showed increased rerupture rate after anterior cruciate ligament (ACL) replacement in patients with increased tibial slope. Concerning the posterior cruciate ligament (PCL)/posterolateral corner (PLC)/lateral collateral ligament (LCL), varus malalignment was considered a significant risk factor for failure. For part B, studies showed decreased anterior tibial translation after slope-decreasing high tibial osteotomy in ACL-deficient knees. Correcting varus malalignment in PCL/PLC/LCL instability also showed increased stability and better outcomes. In cases of complex knee instability, the 3-dimensional osseous alignment of the knee should be considered (eg, mechanical weightbearing line and tibial slope). In cases of failed ACL reconstruction, the tibial slope should be considered, and slope-reducing osteotomies are often helpful in the patient revised multiple times. In cases of chronic PCL and/or PLC instability, osseous correction of the varus alignment may reduce the failure rate and is often the first step in treatment. Changes in the mechanical axis should be considered in all cases of instability accompanied by early unicompartmental osteoarthritis.

  3. The Impact of Osseous Malalignment and Realignment Procedures in Knee Ligament Surgery: A Systematic Review of the Clinical Evidence

    PubMed Central

    Tischer, Thomas; Paul, Jochen; Pape, Dietrich; Hirschmann, Michael T.; Imhoff, Andreas B.; Hinterwimmer, Stefan; Feucht, Matthias J.

    2017-01-01

    Background: Failure rates of knee ligament surgery may be high, and the impact of osseous alignment on surgical outcome remains controversial. Basic science studies have demonstrated that osseous malalignment can negatively affect ligament strain and that realignment procedures may improve knee joint stability. Hypothesis/Purpose: The purpose of this review was to summarize the clinical evidence concerning the impact of osseous malalignment and realignment procedures in knee ligament surgery. The hypotheses were that lower extremity malalignment would be an important contributor to knee ligament surgery failure and that realignment surgery would contribute to increased knee stability and improved outcome in select cases. Study Design: Systematic review; Level of evidence, 4. Methods: According to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines, a systematic electronic search of the PubMed database was performed in November 2015 to identify clinical studies investigating (A) the influence of osseous alignment on postoperative stability and/or failure rates after knee ligament surgery and (B) the impact of osseous realignment procedures in unstable knees with or without additional knee ligament surgery on postoperative knee function and stability. Methodological quality of the studies was assessed using the Oxford Centre for Evidence-Based Medicine Levels of Evidence and the Coleman Methodological Score (CMS). Results: Of the 1466 potentially relevant articles, 28 studies fulfilled the inclusion and exclusion criteria. Average study quality was poor (CMS, 40). For part A, studies showed increased rerupture rate after anterior cruciate ligament (ACL) replacement in patients with increased tibial slope. Concerning the posterior cruciate ligament (PCL)/posterolateral corner (PLC)/lateral collateral ligament (LCL), varus malalignment was considered a significant risk factor for failure. For part B, studies showed decreased anterior tibial translation after slope-decreasing high tibial osteotomy in ACL-deficient knees. Correcting varus malalignment in PCL/PLC/LCL instability also showed increased stability and better outcomes. Conclusion: In cases of complex knee instability, the 3-dimensional osseous alignment of the knee should be considered (eg, mechanical weightbearing line and tibial slope). In cases of failed ACL reconstruction, the tibial slope should be considered, and slope-reducing osteotomies are often helpful in the patient revised multiple times. In cases of chronic PCL and/or PLC instability, osseous correction of the varus alignment may reduce the failure rate and is often the first step in treatment. Changes in the mechanical axis should be considered in all cases of instability accompanied by early unicompartmental osteoarthritis. PMID:28451605

  4. Single-legged Hop Tests as Predictors of Self-reported Knee Function After Anterior Cruciate Ligament Reconstruction

    PubMed Central

    Logerstedt, David; Grindem, Hege; Lynch, Andrew; Eitzen, Ingrid; Engebretsen, Lars; Risberg, May Arna; Axe, Michael J.; Snyder-Mackler, Lynn

    2012-01-01

    Background Single-legged hop tests are commonly used functional performance measures that can capture limb asymmetries in patients after anterior cruciate ligament (ACL) reconstruction. Hop tests hold potential as predictive factors of self-reported knee function in individuals after ACL reconstruction. Hypothesis Single-legged hop tests conducted preoperatively would not and 6 months after ACL reconstruction would predict self-reported knee function (International Knee Documentation Committee [IKDC] 2000) 1 year after ACL reconstruction. Study Design Cohort study (prognosis); Level of evidence, 2. Methods One hundred twenty patients who were treated with ACL reconstruction performed 4 single-legged hop tests preoperatively and 6 months after ACL reconstruction. Self-reported knee function within normal ranges was defined as IKDC 2000 scores greater than or equal to the age- and sex-specific normative 15th percentile score 1 year after surgery. Logistic regression analyses were performed to identify predictors of self-reported knee function within normal ranges. The area under the curve (AUC) from receiver operating characteristic curves was used as a measure of discriminative accuracy. Results Eighty-five patients completed single-legged hop tests 6 months after surgery and the 1-year follow-up with 68 patients classified as having self-reported knee function within normal ranges 1 year after reconstruction. The crossover hop and 6-m timed hop limb symmetry index (LSI) 6 months after ACL reconstruction were the strongest individual predictors of self-reported knee function (odds ratio, 1.09 and 1.10) and the only 2 tests in which the confidence intervals of the discriminatory accuracy (AUC) were above 0.5 (AUC = 0.68). Patients with knee function below normal ranges were over 5 times more likely of having a 6-m timed hop LSI lower than the 88% cutoff than those with knee function within normal ranges. Patients with knee function within normal ranges were 4 times more likely to have a crossover hop LSI greater than the 95% cutoff than those with knee function below normal ranges. No preoperative single-legged hop test predicted self-reported knee function within normal ranges 1 year after ACL reconstruction (all P > .353). Conclusion Single-legged hop tests conducted 6 months after ACL reconstruction can predict the likelihood of successful and unsuccessful outcome 1 year after ACL reconstruction. Patients demonstrating less than the 88% cutoff score on the 6-m timed hop test at 6 months may benefit from targeted training to improve limb symmetry in an attempt to normalize function. Patients with minimal side-to-side differences on the crossover hop test at 6 months possibly will have good knee function at 1 year if they continue with their current training regimen. Preoperative single-legged hop tests are not able to predict postoperative outcomes. PMID:22926749

  5. Human knee joint sound during the Lachman test: Comparison between healthy and anterior cruciate ligament-deficient knees.

    PubMed

    Tanaka, Kazunori; Ogawa, Munehiro; Inagaki, Yusuke; Tanaka, Yasuhito; Nishikawa, Hitoshi; Hattori, Koji

    2017-05-01

    The Lachman test is clinically considered to be a reliable physical examination for anterior cruciate ligament (ACL) deficiency. However, the test involves subjective judgement of differences in tibial translation and endpoint quality. An auscultation system has been developed to allow assessment of the Lachman test. The knee joint sound during the Lachman test was analyzed using fast Fourier transformation. The purpose of the present study was to quantitatively evaluate knee joint sounds in healthy and ACL-deficient human knees. Sixty healthy volunteers and 24 patients with ACL injury were examined. The Lachman test with joint auscultation was evaluated using a microphone. Knee joint sound during the Lachman test (Lachman sound) was analyzed by fast Fourier transformation. As quantitative indices of the Lachman sound, the peak sound (Lachman peak sound) as the maximum relative amplitude (acoustic pressure) and its frequency were used. In healthy volunteers, the mean Lachman peak sound of intact knees was 100.6 Hz in frequency and -45 dB in acoustic pressure. Moreover, a sex difference was found in the frequency of the Lachman peak sound. In patients with ACL injury, the frequency of the Lachman peak sound of the ACL-deficient knees was widely dispersed. In the ACL-deficient knees, the mean Lachman peak sound was 306.8 Hz in frequency and -63.1 dB in acoustic pressure. If the reference range was set at the frequency of the healthy volunteer Lachman peak sound, the sensitivity, specificity, positive predictive value, and negative predictive value were 83.3%, 95.6%, 95.2%, and 85.2%, respectively. Knee joint auscultation during the Lachman test was capable of judging ACL deficiency on the basis of objective data. In particular, the frequency of the Lachman peak sound was able to assess ACL condition. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  6. Comparative biomechanical analysis of current microprocessor-controlled prosthetic knee joints.

    PubMed

    Bellmann, Malte; Schmalz, Thomas; Blumentritt, Siegmar

    2010-04-01

    To investigate and identify functional differences of 4 microprocessor-controlled prosthetic knee joints (C-Leg, Hybrid Knee [also called Energy Knee], Rheo Knee, Adaptive 2). Tested situations were walking on level ground, on stairs and ramps; additionally, the fall prevention potentials for each design were examined. The measuring technology used included an optoelectronic camera system combined with 2 forceplates as well as a mobile spiroergometric system. The study was conducted in a gait laboratory. Subjects with unilateral transfemoral amputations (N=9; mobility grade, 3-4; age, 22-49y) were tested. Participants were fitted and tested with 4 different microprocessor-controlled knee joints. Static prosthetic alignment, time distance parameters, kinematic and kinetic data and metabolic energy consumption. Compared with the Hybrid Knee and the Adaptive 2, the C-Leg offers clear advantages in the provision of adequate swing phase flexion resistances and terminal extension damping during level walking at various speeds, especially at higher walking speeds. The Rheo Knee provides sufficient terminal extension; however, swing phase flexion resistances seem to be too low. The values for metabolic energy consumption show only slight differences during level walking. The joint resistances generated for descending stairs and ramps relieve the contralateral side to varying degrees. When walking on stairs, safety-relevant technical differences between the investigated joint types can be observed. Designs with adequate internal resistances offer stability advantages when the foot is positioned on the step. Stumble recovery tests reveal that the different knee joint designs vary in their effectiveness in preventing the patient from falling. The patient benefits provided by the investigated electronic prosthetic knee joints differ considerably. The C-Leg appears to offer the amputee greater functional and safety-related advantages than the other tested knee joints. Reduced loading of the contralateral side has been demonstrated during ramp and stair descent. Metabolic energy consumption does not vary significantly between the tested knees. Hence, this parameter seems not to be a suitable criterion for assessing microprocessor-controlled knee components. Copyright 2010 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  7. Cross-cultural differences in knee functional status outcomes in a polyglot society represented true disparities not biased by differential item functioning.

    PubMed

    Deutscher, Daniel; Hart, Dennis L; Crane, Paul K; Dickstein, Ruth

    2010-12-01

    Comparative effectiveness research across cultures requires unbiased measures that accurately detect clinical differences between patient groups. The purpose of this study was to assess the presence and impact of differential item functioning (DIF) in knee functional status (FS) items administered using computerized adaptive testing (CAT) as a possible cause for observed differences in outcomes between 2 cultural patient groups in a polyglot society. This study was a secondary analysis of prospectively collected data. We evaluated data from 9,134 patients with knee impairments from outpatient physical therapy clinics in Israel. Items were analyzed for DIF related to sex, age, symptom acuity, surgical history, exercise history, and language used to complete the functional survey (Hebrew versus Russian). Several items exhibited DIF, but unadjusted FS estimates and FS estimates that accounted for DIF were essentially equal (intraclass correlation coefficient [2,1]>.999). No individual patient had a difference between unadjusted and adjusted FS estimates as large as the median standard error of the unadjusted estimates. Differences between groups defined by any of the covariates considered were essentially unchanged when using adjusted instead of unadjusted FS estimates. The greatest group-level impact was <0.3% of 1 standard deviation of the unadjusted FS estimates. Complete data where patients answered all items in the scale would have been preferred for DIF analysis, but only CAT data were available. Differences in FS outcomes between groups of patients with knee impairments who answered the knee CAT in Hebrew or Russian in Israel most likely reflected true differences that may reflect societal disparities in this health outcome.

  8. FUNCTIONAL PERFORMANCE AND KNEE LAXITY IN NORMAL INDIVIDUALS AND IN INDIVIDUALS SUBMITTED TO ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION

    PubMed Central

    de Vasconcelos, Rodrigo Antunes; Bevilaqua-Grossi, Débora; Shimano, Antonio Carlos; Jansen Paccola, Cleber Antonio; Salvini, Tânia Fátima; Prado, Christiane Lanatovits; Mello Junior, Wilson A.

    2015-01-01

    The aim of this study was to analyze the correlation between deficits in the isokinetic peak torque of the knee extensors and flexors with hop tests, postoperative knee laxity and functional scores in normal and ACL- reconstructed subjects with patellar tendon and hamstring tendon autografts. Methods: Sixty male subjects were enrolled and subdivided into three groups: Twenty subjects without knee injuries (GC group) and two groups of 20 subjects submitted to ACL reconstruction with patellar tendon (GTP group) and hamstrings autograft (GTF group). Results: The results showed significant correlation between knee extensors peak torque and performance in the hop tests for GTF and GC groups. There are no significantly correlations between post op knee laxity and Lysholm score compared with the hop tests and peak torque deficits. Concerning the differences between groups, the GTP group showed greater peak torque deficits in knee extensors, worst Lysholm scores and higher percentage of individuals with lower limb symmetry index (ISM) < 90% in both hop tests when compared to the other two groups. Conclusion: It is not recommendable to use only one measurement instrument for the functional evaluation of ACL-reconstructed patients, because significant correlation between peak torque, subject's functional score, knee laxity and hop tests were not observed in all groups. PMID:26998464

  9. [CLINICAL STUDIES ON EFFECT OF ARTHROSCOPIC INTERCONDYLAR FOSSA ANGIOPLASTY ON ABILITY OF NEUROMUSCULAR CONTROL IN ELDERLY PATIENTS WITH KNEE OSTEOARTHRITIS].

    PubMed

    Huang, Jingmin; Wang, Haijiao; Wu, Jiang; Li, Dongchao; Li, Yuhong

    2015-08-01

    To study the effect of arthroscopic intercondylar fossa angioplasty on the ability of neuromuscular control of the knee joint in elderly patients with knee osteoarthritis (KOA). Between June 2012 and March 2013, 20 elderly patients with KOA and in accordance with inclusion and exclusion criteria underwent arthroscopic intercondylar fossa angioplasty (operation group), and 20 healthy elderly people served as control group. There was no significant difference in age, height, weight, and body mass index between 2 groups (P > 0.05). The proprioception capability (using passive regeneration test at measurement angles of 15, 30, and 60°) and quadriceps mobilization [including maximum voluntary contraction (MVC), central activation ratio (CAR), and activation deficit (AD)] were measured to avaluate the neuromuscular control of the knee; the Lysholm score was used to evaluate knee function. The above indexes were measured to assess the knee neuromuscular control and recovery of joint function in patients of operation group at 3, 6, and 9 months after operation. Compared with the control group, MVC, CAR, and Lysholm scores were significantly decreased, and the AD and passive knee angle difference were significantly increased in operation group (P < 0.05) before operation. With the time after operation, the Lysholm score, CAR, and MVC increased gradually, and the AD and the passive knee angle difference decreased gradually. There was no significant difference in the indexes between 2 groups at 9 months after operation (P > 0.05). Arthroscopic intercondylar fossa angioplasty can relieve ACL pressure, abrasion, and impact, which will recover the ability of neuromuscular control, increase proprioception and quadriceps mobilization capacity, and improve the joint function.

  10. Diagnostic validity of physical examination tests for common knee disorders: An overview of systematic reviews and meta-analysis.

    PubMed

    Décary, Simon; Ouellet, Philippe; Vendittoli, Pascal-André; Roy, Jean-Sébastien; Desmeules, François

    2017-01-01

    More evidence on diagnostic validity of physical examination tests for knee disorders is needed to lower frequently used and costly imaging tests. To conduct a systematic review of systematic reviews (SR) and meta-analyses (MA) evaluating the diagnostic validity of physical examination tests for knee disorders. A structured literature search was conducted in five databases until January 2016. Methodological quality was assessed using the AMSTAR. Seventeen reviews were included with mean AMSTAR score of 5.5 ± 2.3. Based on six SR, only the Lachman test for ACL injuries is diagnostically valid when individually performed (Likelihood ratio (LR+):10.2, LR-:0.2). Based on two SR, the Ottawa Knee Rule is a valid screening tool for knee fractures (LR-:0.05). Based on one SR, the EULAR criteria had a post-test probability of 99% for the diagnosis of knee osteoarthritis. Based on two SR, a complete physical examination performed by a trained health provider was found to be diagnostically valid for ACL, PCL and meniscal injuries as well as for cartilage lesions. When individually performed, common physical tests are rarely able to rule in or rule out a specific knee disorder, except the Lachman for ACL injuries. There is low-quality evidence concerning the validity of combining history elements and physical tests. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Effect of spa physiotherapy on the range of motion and muscle strength in women with gonarthrosis.

    PubMed

    Lizis, Paweł

    2013-01-01

    Degeneration arthritis is a chronic disease of undetermined progressiveness and unknown pathogenesis. It can affect one or more joints. It reveals itself most frequently between 40 - 60 years of age, and affects the lives of professionally active individuals. The aim of the presented study was to assess the impact of a 21-day stay at a rehabilitation facility on the range of motion and muscle strength of the knee in women with gonarthrosis. The study group consisted of 30 women aged 50-74 years diagnosed with degeneration of the knee joint. The average age of the study group was 65.9 ± 7.2 years. Patients remained in the 21-day rehabilitation facility of Rehabilitational Hospital No. 21 in Busko Zdrój SP ZOZ, Poland. We measured with the help of protractor in SFTR range the motion bending and straightening of the knee with an accuracy of 1°. The Lovett strength test was assessed of the ischio-tibial muscles, quadriceps, sartorius--acting on the knee joint of the patient. The study was carried out on the first and the last day of the stay in the rehabilitation facility. There was improvement in the range of flexion and strength of muscles acting on the knee joint of the afflicted women. The study showed that 21-day rehabilitation holiday improved the range and strength of the muscles acting on the knee joint of the afflicted women. This proved that comprehensive rehabilitation improves the function of the knee joint with gonarthrosis, prevents disease progression and is an alternative to drug therapy.

  12. The effects of repetitive drop jumps on impact phase joint kinematics and kinetics.

    PubMed

    Weinhandl, Joshua T; Smith, Jeremy D; Dugan, Eric L

    2011-05-01

    The purpose of the study was to investigate the effects of fatigue on lower extremity joint kinematics, and kinetics during repetitive drop jumps. Twelve recreationally active males (n = 6) and females (n = 6) (nine used for analysis) performed repetitive drop jumps until they could no longer reach 80% of their initial drop jump height. Kinematic and kinetic variables were assessed during the impact phase (100 ms) of all jumps. Fatigued landings were performed with increased knee extension, and ankle plantar flexion at initial contact, as well as increased ankle range of motion during the impact phase. Fatigue also resulted in increased peak ankle power absorption and increased energy absorption at the ankle. This was accompanied by an approximately equal reduction in energy absorption at the knee. While the knee extensors were the muscle group primarily responsible for absorbing the impact, individuals compensated for increased knee extension when fatigued by an increased use of the ankle plantar flexors to help absorb the forces during impact. Thus, as fatigue set in and individuals landed with more extended lower extremities, they adopted a landing strategy that shifted a greater burden to the ankle for absorbing the kinetic energy of the impact.

  13. Clinical Tests of Standing Balance in the Knee Osteoarthritis Population: Systematic Review and Meta-analysis

    PubMed Central

    Hatfield, Gillian L.; Morrison, Adam; Wenman, Matthew; Hammond, Connor A.

    2016-01-01

    Background People with knee osteoarthritis (OA) have a high prevalence of falls. Poor standing balance is one risk factor, but the extent of standing balance deficits in people with knee OA is unknown. Purpose The primary purpose of this study was to summarize available data on standing balance in people with knee OA compared with people without knee OA. A secondary purpose was to establish the extent of balance impairment across disease severity. Data Sources A literature search of the MEDLINE, EMBASE, CINAHL, and Web of Science databases through November 19, 2014, was conducted. Study Selection Studies on individuals with knee OA containing clinical, quantifiable measures of standing balance were included. Methodological quality was assessed by 2 reviewers using a 16-item quality index developed for nonrandomized studies. Studies scoring >50% on the index were included. Data Extraction Participant characteristics (age, sex, body mass index, OA severity, compartment involvement, unilateral versus bilateral disease) and balance outcomes were extracted by 2 reviewers. Standardized mean differences were pooled using a random-effects model. Data Synthesis The search yielded 2,716 articles; 8 met selection and quality assessment criteria. The median score on the quality index was 13/17. People with knee OA consistently performed worse than healthy controls on the Step Test, Single-Leg Stance Test, Functional Reach Test, Tandem Stance Test, and Community Balance and Mobility Scale. The pooled standardized mean difference was −1.64 (95% confidence interval=−2.58, −0.69). No differences were observed between varying degrees of malalignment, or between unilateral versus bilateral disease. Limitations No studies compared between-knee OA severities. Thus, expected changes in balance as the disease progresses remain unknown. Conclusions Few studies compared people with knee OA and healthy controls, but those that did showed that people with knee OA performed significantly worse. More research is needed to understand the extent of balance impairments in people with knee OA using easy-to-administer, clinically available tests. PMID:26183586

  14. Pseudogout at the knee joint will frequently occur after hip fracture and lead to the knee pain in the early postoperative period.

    PubMed

    Harato, Kengo; Yoshida, Hiroki

    2015-01-14

    Symptomatic knee joint effusion is frequently observed after hip fracture, which may lead to postoperative knee pain during rehabilitation after hip fracture surgery. However, unfortunately, very little has been reported on this phenomenon in the literature. The purpose of the current study was to investigate the relationship between symptomatic knee effusion and postoperative knee pain and to clarify the reason of the effusion accompanied by hip fracture. A total of 100 patients over 65 years of age with an acute hip fracture after fall were prospectively followed up. Knee effusion was assessed on admission and at the operating room before the surgery. If knee effusion was observed at the time of the surgery, synovial fluid was collected into syringes to investigate the cause of the effusion using a compensated polarized light microscope. Furthermore, for each patient, we evaluated age, sex, radiographic knee osteoarthritis (OA), type of the fracture, laterality, severity of the fracture, and postoperative knee pain during rehabilitation. These factors were compared between patients with and without knee effusion at the time of the surgery. As a statistical analysis, we used Mann-Whitney U-test for patients' age and categorical variables were analyzed by chi-square test or Fisher's exact test. A total of 30 patients presented symptomatic knee effusion at the time of the surgery. In patients with knee effusion, numbers of intertrochanteric fracture, radiographic knee OA, and postoperative knee pain were significantly large compared to those without effusion. In terms of synovial fluid analysis, calcium pyrophosphate dihydrate crystals were observed in 80% of patients with knee effusion. From our study, approximately 63% of patients with knee effusion at the time of the surgery had postoperative knee pain. In addition, this effusion was basically related to pseudogout.

  15. Radiographic assessment of knee-ankle alignment after total knee arthroplasty for varus and valgus knee osteoarthritis.

    PubMed

    Gao, Fuqiang; Ma, Jinhui; Sun, Wei; Guo, Wanshou; Li, Zirong; Wang, Weiguo

    2017-01-01

    There are unanswered questions about knee-ankle alignment after total knee arthroplasty (TKA) for varus and valgus osteoarthritis (OA) of the knee. The aim of this retrospective study was to assess knee-ankle alignment after TKA. The study consisted of 149 patients who had undergone TKA due to varus and valgus knee OA. The alignment and angles in the selected knees and ankles were measured on full-length standing anteroposterior radiographs, both pre-operatively and post-operatively. The paired t-test and Pearson's correlation tests were used for statistical analysis. The results showed that ankle alignment correlated with knee alignment both pre-operatively and postoperatively (P<0.05). The pre-operative malalignment of the knee was corrected (P<0.05), and the ankle tilt angle was accordingly improved in the operative side after TKA (P<0.05). In addition, TKA had little effect on knee-ankle alignment on the non-operative side (P>0.05). These findings indicated that routine TKA could correct the varus or valgus deformity of a knee, and improve the tilt of the ankle. Ankle alignment correlated with knee alignment both pre-operatively and postoperatively. Both pre-operative knee and ankle malalignment can be simultaneously corrected following TKA. Level III. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Fun During Knee Rehabilitation: Feasibility and Acceptability Testing of a New Android-Based Training Device.

    PubMed

    Weber-Spickschen, Thomas Sanjay; Colcuc, Christian; Hanke, Alexander; Clausen, Jan-Dierk; James, Paul Abraham; Horstmann, Hauke

    2017-01-01

    The initial goals of rehabilitation after knee injuries and operations are to achieve full knee extension and to activate quadriceps muscle. In addition to regular physiotherapy, an android-based knee training device is designed to help patients achieve these goals and improve compliance in the early rehabilitation period. This knee training device combines fun in a computer game with muscular training or rehabilitation. Our aim was to test the feasibility and acceptability of this new device. 50 volunteered subjects enrolled to test out the computer game aided device. The first game was the high-striker game, which recorded maximum knee extension power. The second game involved controlling quadriceps muscular power to simulate flying an aeroplane in order to record accuracy of muscle activation. The subjects evaluated this game by completing a simple questionnaire. No technical problem was encountered during the usage of this device. No subjects complained of any discomfort after using this device. Measurements including maximum knee extension power, knee muscle activation and control were recorded successfully. Subjects rated their experience with the device as either excellent or very good and agreed that the device can motivate and monitor the progress of knee rehabilitation training. To the best of our knowledge, this is the first android-based tool available to fast track knee rehabilitation training. All subjects gave very positive feedback to this computer game aided knee device.

  17. Evaluation of potentially modifiable physical factors as predictors of health status in knee osteoarthritis patients referred for physical therapy.

    PubMed

    Gonçalves, Rui Soles; Pinheiro, João Páscoa; Cabri, Jan

    2012-08-01

    The purpose of this cross sectional study was to estimate the contributions of potentially modifiable physical factors to variations in perceived health status in knee osteoarthritis (OA) patients referred for physical therapy. Health status was measured by three questionnaires: Knee injury and Osteoarthritis Outcome Score (KOOS); Knee Outcome Survey - Activities of Daily Living Scale (KOS-ADLS); and Medical Outcomes Study - 36 item Short Form (SF-36). Physical factors were measured by a battery of tests: body mass index (BMI); visual analog scale (VAS) of pain intensity; isometric dynamometry; universal goniometry; step test (ST); timed "up and go" test (TUGT); 20-meter walk test (20MWT); and 6-minute walk test (6MWT). All tests were administered to 136 subjects with symptomatic knee OA (94 females, 42 males; age: 67.2 ± 7.1 years). Multiple stepwise regression analyses revealed that knee muscle strength, VAS of pain intensity, 6MWT, degree of knee flexion and BMI were moderate predictors of health status. In the final models, selected combinations of these potentially modifiable physical factors explained 22% to 37% of the variance in KOOS subscale scores, 40% of the variance in the KOS-ADLS scale score, and 21% to 34% of the variance in physical health SF-36 subscale scores. More research is required in order to evaluate whether therapeutic interventions targeting these potentially modifiable physical factors would improve health status in knee OA patients. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. The biomechanical effect of increased valgus on total knee arthroplasty: a cadaveric study.

    PubMed

    Bryant, Brandon J; Tilan, Justin U; McGarry, Michelle H; Takenaka, Nobuyuki; Kim, William C; Lee, Thay Q

    2014-04-01

    The effects of valgus load on cadaveric knees following total knee arthroplasty (TKA) were investigated using a custom testing system. TKAs were performed on 8 cadaveric knees and tested at 0°, 30°, and 60° knee flexion in both neutral and 5° valgus. Fuji pressure sensitive film was used to quantify contact areas and pressures and MCL strain was determined using a Microscribe digitizing system. Lateral tibiofemoral pressures increased (P < 0.05) at all knee flexion angles with valgus loading. Patellofemoral contact characteristics did not change significantly (P > 0.05). Significant increases in strain were observed along the anterior and posterior border of the MCL at all knee flexion angles. These findings suggest that valgus loading increases TKA joint contact pressures and MCL strain with increasing knee flexion which may increase implant instability. © 2014.

  19. Epidemiology and history of knee injury and its impact on activity limitation among football premier league professional referees.

    PubMed

    Mahdavi Mohtasham, Hamid; Shahrbanian, Shahnaz; Khoshroo, Fatemeh

    2018-01-01

    The purpose of this study was to determine the epidemiology and history of knee injury and its impact on activity limitation among football premier league professional referees in Iran. This was a descriptive study. 59 Football Premier League professional referees participated in the study. The knee injury related information such as injury history and mechanism was recorded. Injury related symptoms and their impacts on the activity limitation, ability to perform activities of daily living as well participation in sports and recreational activities was obtained through the Knee Outcome Survey (KOS). The results indicated that 31 out of 59 participants reported the history of knee injury. In addition, 18.6%, 22.4% and 81% of the referees reported that they had been injured during the last 6 months of the last year, and at some point in their refereeing careers, respectively. Results further indicated that 48.8% of the injuries occurred in the non-dominant leg and they occurred more frequently during training sessions (52%). Furthermore, the value of KOS was 85 ± 13 for Activities of Daily Living subscale and 90 ± 9 for Sports and Recreational Activities subscale of the KOS. Knee injury was quite common among the Football Premier League professional referees. It was also indicated that the injuries occurred mainly due to insufficient physical fitness. Therefore, it is suggested that football referees undergo the proper warm-up program to avoid knee injury.

  20. Initial derivation of diagnostic clusters combining history elements and physical examination tests for symptomatic knee osteoarthritis.

    PubMed

    Décary, Simon; Feldman, Debbie; Frémont, Pierre; Pelletier, Jean-Pierre; Martel-Pelletier, Johanne; Fallaha, Michel; Pelletier, Bruno; Belzile, Sylvain; Sylvestre, Marie-Pierre; Vendittoli, Pascal-André; Desmeules, François

    2018-05-21

    The aim of the present study was to assess the validity of clusters combining history elements and physical examination tests to diagnose symptomatic knee osteoarthritis (SOA) compared with other knee disorders. This was a prospective diagnostic accuracy study, in which 279 consecutive patients consulting for a knee complaint were assessed. History elements and standardized physical examination tests were obtained independently by a physiotherapist and compared with an expert physician's composite diagnosis, including clinical examination and imaging. Recursive partitioning was used to develop diagnostic clusters for SOA. Diagnostic accuracy measures were calculated, including sensitivity, specificity, and positive and negative likelihood ratios (LR+/-), with associated 95% confidence intervals (CIs). A total of 129 patients had a diagnosis of SOA (46.2%). Most cases (76%) had combined tibiofemoral and patellofemoral knee OA and 63% had radiological Kellgren-Lawrence grades of 2 or 3. Different combinations of history elements and physical examination tests were used in clusters accurately to discriminate SOA from other knee disorders. These included age of patients, body mass index, presence of valgus/varus knee misalignment, palpable knee crepitus and limited passive knee extension. Two clusters to rule in SOA reached an LR+ of 13.6 (95% CI 6.5 to 28.4) and three clusters to rule out SOA reached an LR- of 0.11 (95% CI 0.06 to 0.20). Diagnostic clusters combining history elements and physical examination tests were able to support the differential diagnosis of SOA compared with various knee disorders without relying systematically on imaging. This could support primary care clinicians' role in the efficient management of these patients. Copyright © 2018 John Wiley & Sons, Ltd.

  1. Impact of Clinical Practice Guidelines on Use of Intra-Articular Hyaluronic Acid and Corticosteroid Injections for Knee Osteoarthritis.

    PubMed

    Bedard, Nicholas A; DeMik, David E; Glass, Natalie A; Burnett, Robert A; Bozic, Kevin J; Callaghan, John J

    2018-05-16

    The efficacy of corticosteroid and hyaluronic acid injections for knee osteoarthritis has been questioned. The purpose of this study was to determine the impact of the American Academy of Orthopaedic Surgeons (AAOS) clinical practice guidelines on the use of these injections in the United States and determine if utilization differed by provider specialty. Patients with knee osteoarthritis were identified within the Humana database from 2007 to 2015, and the percentage of patients receiving a knee injection relative to the number of patients having an encounter for knee osteoarthritis was calculated and was trended for the study period. The impact of each edition of the AAOS clinical practice guidelines on injection use was evaluated with segmented regression analysis. Injection trends were also analyzed relative to the specialty of the provider performing the injection. Of 1,065,175 patients with knee osteoarthritis, 405,101 (38.0%) received a corticosteroid injection and 137,005 (12.9%) received a hyaluronic acid injection. The rate of increase in hyaluronic acid use, per 100 patients with knee osteoarthritis, decreased from 0.15 to 0.07 injection per quarter year (p = 0.02) after the first clinical practice guideline, and the increase changed to a decrease at a rate of -0.12 injection per quarter (p < 0.001) after the second clinical practice guideline. After the first clinical practice guideline, the rate of increase in utilization of corticosteroids, per 100 patients with knee osteoarthritis, significantly lessened to 0.12 injection per quarter (p < 0.001), and after the second clinical practice guideline, corticosteroid injection use plateaued (p = 0.72). The trend in use of hyaluronic acid injections by orthopaedic surgeons and pain specialists decreased with time following the second-edition clinical practice guideline but did not change for primary care physicians or nonoperative musculoskeletal providers. Subtle but significant changes in hyaluronic acid and corticosteroid injections occurred following the publication of both clinical practice guidelines. Although the clinical practice guidelines did impact injection use, given the high costs of these injections and their questionable clinical efficacy, further interventions beyond publishing clinical practice guidelines are needed to encourage higher-value care for patients with knee osteoarthritis.

  2. Inter- and intrarater reliability of two proprioception tests using clinical applicable measurement tools in subjects with and without knee osteoarthritis.

    PubMed

    Baert, Isabel A C; Lluch, Enrique; Struyf, Thomas; Peeters, Greta; Van Oosterwijck, Sophie; Tuynman, Joanna; Rufai, Salim; Struyf, Filip

    2018-06-01

    The therapeutic value of proprioceptive-based exercises in knee osteoarthritis (KOA) management warrants investigation of proprioceptive testing methods easily accessible in clinical practice. To estimate inter- and intrarater reliability of the knee joint position sense (KJPS) test and knee force sense (KFS) test in subjects with and without KOA. Cross-sectional test-retest design. Two blinded raters performed independently repeated measures of the KJPS and KFS test, using an analogue inclinometer and handheld dynamometer, respectively, in eight KOA patients (12 symptomatic knees) and 26 healthy controls (52 asymptomatic knees). Intraclass correlation coefficients (ICCs; model 2,1), standard error of measurement (SEM) and minimal detectable change with 95% confidence bounds (MDC 95 ) were calculated. For KJPS, results showed good to excellent test-retest agreement (ICCs 0.70-0.95 in KOA patients; ICCs 0.65-0.85 in healthy controls). A 2° measurement error (SEM 1°) was reported when measuring KJPS in multiple test positions and calculating mean repositioning error. Testing KOA patients pre and post therapy a repositioning error larger than 4° (MDC 95 ) is needed to consider true change. Measuring KFS using handheld dynamometry showed poor to fair interrater and poor to excellent intrarater reliability in subjects with and without KOA. Measuring KJPS in multiple test positions using an analogue inclinometer and calculating mean repositioning error is reliable and can be used in clinical practice. We do not recommend the use of the KFS test to clinicians. Further research is required to establish diagnostic accuracy and validity of our KJPS test in larger knee pain populations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Effect of static and dynamic muscle stretching as part of warm up procedures on knee joint proprioception and strength.

    PubMed

    Walsh, Gregory S

    2017-10-01

    The importance of warm up procedures prior to athletic performance is well established. A common component of such procedures is muscle stretching. There is conflicting evidence regarding the effect of static stretching (SS) as part of warm up procedures on knee joint position sense (KJPS) and the effect of dynamic stretching (DS) on KJPS is currently unknown. The aim of this study was to determine the effect of dynamic and static stretching as part warm up procedures on KJPS and knee extension and flexion strength. This study had a randomised cross-over design and ten healthy adults (20±1years) attended 3 visits during which baseline KJPS, at target angles of 20° and 45°, and knee extension and flexion strength tests were followed by 15min of cycling and either a rest period (CON), SS, or DS and repeat KJPS and strength tests. All participants performed all conditions, one condition per visit. There were warm up×stretching type interactions for KJPS at 20° (p=0.024) and 45° (p=0.018), and knee flexion (p=0.002) and extension (p<0.001) strength. The SS and DS improved KJPS but CON condition did not and SS decreased strength. No change in strength was present for DS or CON. Both SS and DS improve KJPS as part of pre-exercise warm up procedures. However, the negative impact of SS on muscle strength limits the utility of SS before athletic performance. If stretching is to be performed as part of a warm up, DS should be favoured over SS. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Intrarater reliability of the Humac NORM isokinetic dynamometer for strength measurements of the knee and shoulder muscles.

    PubMed

    Habets, Bas; Staal, J Bart; Tijssen, Marsha; van Cingel, Robert

    2018-01-10

    To determine the intrarater reliability of the Humac NORM isokinetic dynamometer for concentric and eccentric strength tests of knee and shoulder muscles. 54 participants (50% female, average age 20.9 ± 3.1 years) performed concentric and eccentric strength measures of the knee extensors and flexors, and the shoulder internal and external rotators on two different Humac NORM isokinetic dynamometers, which were situated at two different centers. The knee extensors and flexors were tested concentrically at 60° and 180°/s, and eccentrically at 60° s. Concentric strength of the shoulder internal and external rotators, and eccentric strength of the external rotators were measured at 60° and 120°/s. We calculated intraclass correlation coefficients (ICCs), standard error of measurement, standard error of measurement expressed as a %, and the smallest detectable change to determine reliability and measurement error. ICCs for the knee tests ranged from 0.74 to 0.89, whereas ICC values for the shoulder tests ranged from 0.72 to 0.94. Measurement error was highest for the concentric test of the knee extensors and lowest for the concentric test of shoulder external rotators.

  5. Physical performance measurement in persons with patellofemoral osteoarthritis: A pilot study.

    PubMed

    Hoglund, Lisa T; Lockard, Margery A; Barbe, Mary F; Hillstrom, Howard J; Song, Jinsup; Reinus, William R; Barr-Gillespie, Ann E

    2015-01-01

    Patellofemoral osteoarthritis (PFOA) is associated with pain and decreased self-reported function. The impact of PFOA on actual physical performance is currently unknown. To investigate the impact of PFOA on physical performance and pain. Eight participants aged 40-65 years with bilateral, symptomatic, radiographic PFOA and 7 age- and gender-matched pain-free control participants without radiographic PFOA were studied. Physical performance was measured with the Timed-Up-and-Go (TUG) and 50-foot Fast-Paced-Walk (FPW) tests. Dependent variables included time to complete the TUG and FPW; pretest-posttest change in pain intensity (TUG and FPW); and self-reports of perceived knee pain, stiffness, and physical function. Data were analyzed with nonparametric statistics. The PFOA group TUG time was longer than the control group (p=0.01). No difference between groups was found for FPW time. Pretest-posttest pain increased for the TUG and FPW in PFOA participants (p< 0.05). The PFOA group reported greater knee pain, stiffness, and less physical function than controls (previous 48 hours) (p < 0.01). Symptomatic, radiographic PFOA is associated with increased pain during the TUG and FPW tests and longer time required to complete the TUG. The TUG may be a more sensitive test of physical performance in PFOA.

  6. Fun During Knee Rehabilitation: Feasibility and Acceptability Testing of a New Android-Based Training Device

    PubMed Central

    Weber-Spickschen, Thomas Sanjay; Colcuc, Christian; Hanke, Alexander; Clausen, Jan-Dierk; James, Paul Abraham; Horstmann, Hauke

    2017-01-01

    Purpose: The initial goals of rehabilitation after knee injuries and operations are to achieve full knee extension and to activate quadriceps muscle. In addition to regular physiotherapy, an android-based knee training device is designed to help patients achieve these goals and improve compliance in the early rehabilitation period. This knee training device combines fun in a computer game with muscular training or rehabilitation. Our aim was to test the feasibility and acceptability of this new device. Methods: 50 volunteered subjects enrolled to test out the computer game aided device. The first game was the high-striker game, which recorded maximum knee extension power. The second game involved controlling quadriceps muscular power to simulate flying an aeroplane in order to record accuracy of muscle activation. The subjects evaluated this game by completing a simple questionnaire. Results: No technical problem was encountered during the usage of this device. No subjects complained of any discomfort after using this device. Measurements including maximum knee extension power, knee muscle activation and control were recorded successfully. Subjects rated their experience with the device as either excellent or very good and agreed that the device can motivate and monitor the progress of knee rehabilitation training. Conclusion: To the best of our knowledge, this is the first android-based tool available to fast track knee rehabilitation training. All subjects gave very positive feedback to this computer game aided knee device. PMID:29081870

  7. Effect of knee flexion angle on ground reaction forces, knee moments and muscle co-contraction during an impact-like deceleration landing: implications for the non-contact mechanism of ACL injury.

    PubMed

    Podraza, Jeffery T; White, Scott C

    2010-08-01

    Investigating landing kinetics and neuromuscular control strategies during rapid deceleration movements is a prerequisite to understanding the non-contact mechanism of ACL injury. The purpose of this study was to quantify the effect of knee flexion angle on ground reaction forces, net knee joint moments, muscle co-contraction and lower extremity muscles during an impact-like, deceleration task. Ground reaction forces and knee joint moments were determined from video and force plate records of 10 healthy male subjects performing rapid deceleration single leg landings from a 10.5 cm height with different degrees of knee flexion at landing. Muscle co-contraction was based on muscle moments calculated from an EMG-to-moment processing model. Ground reaction forces and co-contraction indices decreased while knee extensor moments increased significantly with increased degrees of knee flexion at landing (all p<0.005). Higher ground reaction forces when landing in an extended knee position suggests they are a contributing factor in non-contact ACL injuries. Increased knee extensor moments and less co-contraction with flexed knee landings suggest that quadriceps overload may not be the primary cause of non-contact ACL injuries. The results bring into question the counterbalancing role of the hamstrings during dynamic movements. The soleus may be a valuable synergist stabilizing the tibia against anterior translation at landing. Movement strategies that lessen the propagation of reaction forces up the kinetic chain may help prevent non-contact ACL injuries. The relative interaction of all involved thigh and lower leg muscles, not just the quadriceps and hamstrings should be considered when interpreting non-contact ACL injury mechanisms. Copyright 2010 Elsevier B.V. All rights reserved.

  8. Prevalence, risk factors, and impact of knee pain suggesting osteoarthritis in Spain.

    PubMed

    Fernandez-Lopez, J C; Laffon, A; Blanco, F J; Carmona, L

    2008-01-01

    To estimate the point prevalence of knee pain suggesting osteoarthritis (OA) in the adult Spanish population. Secondary objectives were to examine the distribution of associated factors, as well as to assess the impact of knee pain on quality of life and function in the general population. A population survey was conducted in year 2000 for which 2,192 subjects over 20 years of age were selected by stratified polystage cluster sampling from the censuses of 20 towns. Trained rheumatologists administered structured interviews that permitted them to rule out the presence of rheumatic symptoms, and which included validated instruments to measure function and quality of life. We used the definition of clinical symptomatic knee OA of the American College of Rheumatology. The estimated prevalence of knee pain suggesting OA in the general adult population is 10.2% (95% confidence interval: 7.9-12.5). Elderly women with fewer studies and from the lower social class, as well as those subjects involved in physically demanding jobs are more frequently affected. Obesity is also an important determinant for knee pain suggesting OA. Knee pain is associated to a significant decrease in functional ability and quality of life, even after adjustment for age, sex, and comorbidity. The prevalence of knee pain suggesting OA in the general Spanish population is higher than expected, mainly related to a high rate of knee pain in women over 55. The proportion of very old persons and of those obese are important factors to take into account when comparing the rate of knee OA between populations.

  9. Reliability and diagnostic validity of the slump knee bend neurodynamic test for upper/mid lumbar nerve root compression: a pilot study.

    PubMed

    Trainor, Kate; Pinnington, Mark A

    2011-03-01

    It has been proposed that neurodynamic examination can assist differential diagnosis of upper/mid lumbar nerve root compression; however, the diagnostic validity of many of these tests has yet to be established. This pilot study aimed to establish the diagnostic validity of the slump knee bend neurodynamic test for upper/mid lumbar nerve root compression in subjects with suspected lumbosacral radicular pain. Two independent examiners performed the slump knee bend test on subjects with radicular leg pain. Inter-tester reliability was calculated using the kappa coefficient. Slump knee bend test results were compared with magnetic resonance imaging findings, and diagnostic accuracy measures were calculated including sensitivity, specificity, predictive values and likelihood ratios. Orthopaedic spinal clinic, secondary care. Sixteen patients with radicular leg pain. All four subjects with mid lumbar nerve root compression on magnetic resonance imaging were correctly identified with the slump knee bend test; however, it was falsely positive in two individuals without the condition. Inter-tester reliability for the slump knee bend test using the kappa coefficient was 0.71 (95% confidence interval 0.33 to 1.0). Diagnostic validity calculations for the slump knee bend test (95% confidence intervals) were: sensitivity, 100% (40 to 100%); specificity, 83% (52 to 98%); positive predictive value, 67% (22 to 96%); negative predictive value, 100% (69 to 100%); positive likelihood ratio, 6.0 (1.58 to 19.4); and negative likelihood ratio, 0 (0 to 0.6). Results indicate good inter-tester reliability and suggest that the slump knee bend test has potential to be a useful clinical test for identifying patients with mid lumbar nerve root compression. Further investigation is needed on larger numbers of patients to confirm these findings. Copyright © 2010 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  10. Use of Kinesiology Taping in Rehabilitation after Knee Arthroplasty: a Randomised Clinical Study.

    PubMed

    Woźniak-Czekierda, Weronika; Woźniak, Kamil; Hadamus, Anna; Białoszewski, Dariusz

    2017-10-31

    Proprioception and body balance after knee arthroplasty have a considerable impact on restoration of joint function and a normal gait pattern. Kinesiology Taping (KT) is a method that may be able to influence these factors. The aim of this study was to assess the effects of KT application on sensorimotor efficiency, balance and gait in patients undergoing rehabili-ta--tion after knee replacement surgery. The study involved 120 male and female patients (mean age was 69 years) after total knee repla-cement. The patients were randomly assigned to one of two groups: Experimental Group (n=51) and Control Group (n=60). Both groups underwent standard rehabilitation lasting 20 days. In addition, the Experimental Group received KT applications. Treat-ment outcomes were assessed based on tests evaluating balance, joint position sense and functional gait performance, conducted both before and after the therapy. Statistically significant improvements were noted across all the parameters assessed in the Experimental Group (p<0.005). Significant improvements were also seen in the Control Group (p<0.005), but, in percentage terms, the improvement was higher in the Experimental Group. The only exception was the right/left foot load distribution, whose symmetry improved proportionally in both groups. 1. Patients after knee replacement surgery have considerable proprioception deficits, impaired body balance and reduced functional performance, which may increase the risk of falls in this group of patients. 2. Both standard physiotherapy and combination therapy with Kinesiology Taping (modified by the present authors) used in patients after knee arthroplasty may considerably improve the level of proprioception, body balance and overall functional performance. 3. The technique of dynamic taping proposed in this paper may optimise standard physiotherapy used in patients after knee arthroplasty and increase its clinical efficacy. Further studies are required.

  11. Longitudinal (4 year) change of thigh muscle and adipose tissue distribution in chronically painful vs. painless knees – data from the Osteoarthritis Initiative

    PubMed Central

    Ruhdorfer, Anja; Wirth, Wolfgang; Dannhauer, Torben; Eckstein, Felix

    2015-01-01

    Objective To evaluate 4-year longitudinal change in thigh muscle and adipose tissue content in chronically painful versus painless knees. Methods Knees from Osteoarthritis Initiative participants with non-acceptable symptom status (numerical rating scale ≥4) and frequent pain (≥6 months at baseline, year 2 and year 4 follow-up) were studied. These were matched with painless controls (bilateral NRS pain intensity≤1 and ≤infrequent pain at all 3 timepoints). 4-year longitudinal changes in thigh muscle anatomical cross-sectional areas (CSAs), isometric muscle strength, and in subcutaneous (SCF) and intermuscular fat (IMF) CSAs were obtained from magnetic resonance images (MRI) and were compared between groups (paired t-tests). Results 43 participants fulfilled the inclusion criteria of chronic pain, had complete thigh muscle MRI acquisitions and strength measurements, and a matched control. Quadriceps CSAs, but not extensor strength, showed a significant longitudinal decrease in chronically painful knees (-3.9%; 95%confidence interval [95 CI] -6.3%,-1.5%) and in painless controls (-2.4%; 95% CI -4.1%, -0.7%); the difference in change was not statistically significant (p=0.33). There was a significant 4-year gain in SCF in painful knees (8.1%; 95% CI 3.1%, 13%) but not in controls (0.0%; 95%CI -4.4%, +4.4%) with the difference in change being significant (p=0.03). The gain in IMF (∼5.2%) was similar between painful and painless knees. Conclusion This is the first paper to show a significant impact of (chronic) knee pain on longitudinal change in local subcutaneous adipose tissue. The effect of pain on subcutaneous fat appeared stronger than that on intermuscular adipose tissue and on muscle status. PMID:25887367

  12. A Kinematic Analysis of the Jumping Front-Leg Axe-Kick in Taekwondo

    PubMed Central

    Preuschl, Emanuel; Hassmann, Michaela; Baca, Arnold

    2016-01-01

    The jumping front-leg axe-kick is a valid attacking and counterattacking technique in Taekwondo competition (Streif, 1993). Yet, the existing literature on this technique is sparse (Kloiber et al., 2009). Therefore, the goal of this study was to determine parameters contributing significantly to maximum linear speed of the foot at impact. Parameters are timing of segment and joint angular velocity characteristics and segment lengths of the kicking leg. Moreover, we were interested in the prevalence of proximal-to-distal-sequencing. Three-dimensional kinematics of the kicks of 22 male Taekwondo-athletes (age: 23.3 ± 5.3 years) were recorded via a motion capturing system (Vicon Motion Systems Limited, Oxford, UK). The participants performed maximum effort kicks onto a rack-held kicking pad. Only the kick with the highest impact velocity was analysed, as it was assumed to represent the individual’s best performance. Significant Pearson correlations to impact velocity were found for pelvis tilt angular displacement (r = 0.468, p < 0.05) and for hip extension angular velocity (r = -0.446, p < 0.05) and for the timing of the minima of pelvis tilt velocity (r = -0.426, p < 0.05) and knee flexion velocity (r = -0.480, p < 0.05). Backward step linear regression analysis suggests a model consisting of three predictor variables: pelvis tilt angular displacement, hip flexion velocity at target contact and timing of pelvic tilt angular velocity minimum (adjusted R2 = 0.524). Results of Chi-Squared tests show that neither for the leg-raising period (χ2 = 2.909) of the technique, nor for the leg-lowering period a pattern of proximal-to-distal sequencing is prevalent (χ2 = 0.727). From the results we conclude that the jumping front-leg axe-kick does not follow a proximal-to-distal pattern. Raising the leg early in the technique and apprehending the upper body to be leant back during the leg-lowering period seems to be beneficial for high impact velocity. Furthermore, striking by extending the hip rather than by flexing the knee could raise impact velocity. Key points Angular velocity characteristics of the pelvis segment and the kicking leg’s hip and knee joint show no proximal-to-distal sequencing, neither for the leg-raising or leg-lowering period in a jumping front-leg axe-kick. Anthropometric parameters of taekwondo athlete’s do not influence their impact velocities. In order to raise the impact velocity in the jumping front-leg axe-kick an athlete should avoid tilting back with the torso. Instead, an upright position should be maintained. In the leg-lowering period, we suggest hitting the target by using hip extension with a rather straight knee, instead of flexing the knee. PMID:26957931

  13. The Impact of Personality Traits on the Outcome of Total Knee Arthroplasty.

    PubMed

    Giurea, A; Fraberger, G; Kolbitsch, P; Lass, R; Schneider, E; Kubista, B; Windhager, R

    2016-01-01

    Ten to twenty percent of patients with total knee arthroplasty (TKA) are dissatisfied with their clinical outcome. Aim of this study was to investigate the impact of personality traits on the subjective outcome of TKA. We investigated 80 patients with 86 computer navigated TKAs. We asked for patients satisfaction and divided patients into two groups (satisfied or dissatisfied). 12 personality traits were tested by the Freiburg Personality Inventory (FPI-R). Postoperative examination included Knee Society Score (KSS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC), and the Visual Analogue Scale (VAS). Radiologic investigation was done in all patients. 84% of our patients were satisfied, while 16% were not satisfied. The FPI-R showed statistical significant influence of four personality traits on patient satisfaction: life satisfaction (p = 0.006), performance orientation (p = 0.015), somatic distress (p = 0.001), and emotional stability (p = 0.002). All clinical scores (VAS, WOMAC, and KSS) showed significantly better results in the satisfied patient. Radiological examination showed optimal alignment of all TKAs. There were no complications requiring revision surgery. The results of our study show that personality traits may influence patients satisfaction and clinical outcome after TKA. Therefore patients personality traits may be a useful predictive factor for postoperative satisfaction after TKA.

  14. The Impact of Personality Traits on the Outcome of Total Knee Arthroplasty

    PubMed Central

    Giurea, A.; Fraberger, G.; Kolbitsch, P.; Lass, R.; Schneider, E.; Kubista, B.; Windhager, R.

    2016-01-01

    Ten to twenty percent of patients with total knee arthroplasty (TKA) are dissatisfied with their clinical outcome. Aim of this study was to investigate the impact of personality traits on the subjective outcome of TKA. We investigated 80 patients with 86 computer navigated TKAs. We asked for patients satisfaction and divided patients into two groups (satisfied or dissatisfied). 12 personality traits were tested by the Freiburg Personality Inventory (FPI-R). Postoperative examination included Knee Society Score (KSS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC), and the Visual Analogue Scale (VAS). Radiologic investigation was done in all patients. 84% of our patients were satisfied, while 16% were not satisfied. The FPI-R showed statistical significant influence of four personality traits on patient satisfaction: life satisfaction (p = 0.006), performance orientation (p = 0.015), somatic distress (p = 0.001), and emotional stability (p = 0.002). All clinical scores (VAS, WOMAC, and KSS) showed significantly better results in the satisfied patient. Radiological examination showed optimal alignment of all TKAs. There were no complications requiring revision surgery. The results of our study show that personality traits may influence patients satisfaction and clinical outcome after TKA. Therefore patients personality traits may be a useful predictive factor for postoperative satisfaction after TKA. PMID:26989686

  15. Measurement of knee stiffness and laxity in patients with documented absence of the anterior cruciate ligament.

    PubMed

    Markolf, K L; Kochan, A; Amstutz, H C

    1984-02-01

    Thirty-five patients with documented absence of the anterior cruciate ligament were tested on the University of California, Los Angeles, instrumented clinical knee-testing apparatus and we measured the response curves for the following testing modes: anterior-posterior force versus displacement at full extension and at 20 and 90 degrees of flexion; varus-valgus moment versus angulation at full extension and 20 degrees of flexion; and tibial torque versus rotation at 20 degrees of flexion. Absolute values of stiffness and laxity and right-left differences for these injured knees were compared with identical quantities measured previously for a control population of forty-nine normal subjects with no history of treatment for injury to the knee. For both the uninjured knees and the knees without an anterior cruciate ligament, at 20 and 90 degrees of flexion the anterior-posterior laxity was greatest at approximately 15 degrees of external rotation of the foot. The injured knees demonstrated significantly increased total anterior-posterior laxity and decreased anterior stiffness when compared with the uninjured knees in all tested positions of the foot and knee. The mean increase in paired anterior-posterior laxity for the injured knees in this group of patients at +/- 200 newtons of applied anterior-posterior force was 3.1 millimeters (+39 per cent) at full extension, 5.5 millimeters (+57 per cent) at 20 degrees of flexion, and 2.5 millimeters (+34 per cent) at 90 degrees of flexion. The mean reduction in anterior stiffness for injured knees was also greatest (-54 per cent) at 20 degrees of knee flexion. Only slight reduction in posterior stiffness (-16 per cent) was measured at 20 degrees of flexion, and this probably reflected the presence of associated capsular and meniscal injuries. In the group of anterior cruciate-deficient knees, the patients with an absent medial meniscus showed greater total anterior-posterior laxity in all three positions of knee flexion than did the patients with an intact or torn meniscus. Varus-valgus laxity at full extension increased an average of 1.7 degrees (+36 per cent) for the injured knees, while varus and valgus stiffness decreased 21 per cent and 24 per cent. Absence of the medial meniscus (in a knee with absence of the anterior cruciate ligament) increased varus-valgus laxity at zero and 20 degrees of flexion.(ABSTRACT TRUNCATED AT 400 WORDS)

  16. Delayed diagnosis of an isolated posterolateral corner injury: a case report

    PubMed Central

    Welsh, Patrick; DeGraauw, Christopher; Whitty, David

    2016-01-01

    Introduction: Isolated injuries to the posterolateral corner of the knee are a rare and commonly missed injury associated with athletic trauma, motor vehicle accidents, and falls. Delayed or missed diagnoses can negatively impact patient prognosis, contributing to residual instability, chronic pain, and failure of surgical repair to other ligaments. Case Presentation: A 44-year-old male CrossFit athlete presented with a history of two non-contact hyperextension injuries to his left knee while walking on ice. The only positive finding was the Dial Test at 30 degrees of knee flexion, indicative of an isolated posterolateral corner injury. After a delay in diagnosis, the patient underwent a reconstruction of the posterolateral corner and subsequent rehabilitation. Early recognition of this injury is important as this can affect the prognosis and activities of daily living of the patient. Summary: This case will discuss the clinical presentation, diagnostic procedures, and management of an isolated posterolateral corner injury and highlight the importance of early recognition and referrals from primary contact healthcare practitioners. PMID:28065990

  17. Delayed diagnosis of an isolated posterolateral corner injury: a case report.

    PubMed

    Welsh, Patrick; DeGraauw, Christopher; Whitty, David

    2016-12-01

    Isolated injuries to the posterolateral corner of the knee are a rare and commonly missed injury associated with athletic trauma, motor vehicle accidents, and falls. Delayed or missed diagnoses can negatively impact patient prognosis, contributing to residual instability, chronic pain, and failure of surgical repair to other ligaments. A 44-year-old male CrossFit athlete presented with a history of two non-contact hyperextension injuries to his left knee while walking on ice. The only positive finding was the Dial Test at 30 degrees of knee flexion, indicative of an isolated posterolateral corner injury. After a delay in diagnosis, the patient underwent a reconstruction of the posterolateral corner and subsequent rehabilitation. Early recognition of this injury is important as this can affect the prognosis and activities of daily living of the patient. This case will discuss the clinical presentation, diagnostic procedures, and management of an isolated posterolateral corner injury and highlight the importance of early recognition and referrals from primary contact healthcare practitioners.

  18. Effect of tibial positioning on the diagnosis of posterolateral rotatory instability in the posterior cruciate ligament-deficient knee.

    PubMed

    Strauss, Eric J; Ishak, Charbel; Inzerillo, Christopher; Walsh, Michael; Yildirim, Gokce; Walker, Peter; Jazrawi, Laith; Rosen, Jeffrey

    2007-08-01

    To determine whether positioning of the tibia affects the degree of tibial external rotation seen during a dial test in the posterior cruciate ligament (PCL)-posterolateral corner (PLC)-deficient knee. Laboratory investigation. Biomechanics laboratory. An anterior force applied to the tibia in the combined PCL-PLC-deficient knee will yield increased tibial external rotation during a dial test. The degree of tibial external rotation was measured with 5 Nm of external rotation torque applied to the tibia at both 30 degrees and 90 degrees of knee flexion. Before the torque was applied, an anterior force, a posterior force, or neutral (normal, reduced control) force was applied to the tibia. External rotation measurements were repeated after sequential sectioning of the PCL, the posterolateral structures and the fibular collateral ligament (FCL). Baseline testing of the intact specimens demonstrated a mean external rotation of 18.6 degrees with the knee flexed to 30 degrees (range 16.1-21.0 degrees ), and a mean external rotation of 17.3 degrees with the knee flexed to 90 degrees (range 13.8-20.0 degrees ). Sequential sectioning of the PCL, popliteus and popliteofibular ligament, and the FCL led to a significant increase in tibial external rotation compared with the intact knee for all testing scenarios. After sectioning of the popliteus and popliteofibular ligament, the application of an anterior force during testing led to a mean tibial external rotation that was 5 degrees greater than during testing in the neutral position and 7.5 degrees greater than during testing with a posterior force. In the PCL, popliteus/popliteofibular ligament and FCL-deficient knee, external rotation was 9 degrees and 12 degrees greater with the application of an anterior force during testing compared with neutral positioning and the application of a posterior force, respectively. An anterior force applied to the tibia during the dial test in a combined PCL-PLC-injured knee increased the overall amount of observed tibial external rotation during the dial test. The anterior force reduced the posterior tibial subluxation associated with PCL injury, which is analogous to what is observed when the dial test is performed with the patient in the prone position. Reducing the tibia with either an anterior force when the patient is supine or performing the dial test with the patient in the prone position increases the ability of an examiner to detect a concomitant PLC injury in the setting of a PCL-deficient knee.

  19. Computational knee ligament modeling using experimentally determined zero-load lengths.

    PubMed

    Bloemker, Katherine H; Guess, Trent M; Maletsky, Lorin; Dodd, Kevin

    2012-01-01

    This study presents a subject-specific method of determining the zero-load lengths of the cruciate and collateral ligaments in computational knee modeling. Three cadaver knees were tested in a dynamic knee simulator. The cadaver knees also underwent manual envelope of motion testing to find their passive range of motion in order to determine the zero-load lengths for each ligament bundle. Computational multibody knee models were created for each knee and model kinematics were compared to experimental kinematics for a simulated walk cycle. One-dimensional non-linear spring damper elements were used to represent cruciate and collateral ligament bundles in the knee models. This study found that knee kinematics were highly sensitive to altering of the zero-load length. The results also suggest optimal methods for defining each of the ligament bundle zero-load lengths, regardless of the subject. These results verify the importance of the zero-load length when modeling the knee joint and verify that manual envelope of motion measurements can be used to determine the passive range of motion of the knee joint. It is also believed that the method described here for determining zero-load length can be used for in vitro or in vivo subject-specific computational models.

  20. Multi-factorial sustainability approach is necessary to preserve knee function following osteoarthritis diagnosis.

    PubMed

    Nyland, John; Jakob, Roland

    2013-10-18

    Knee function preservation following a diagnosis of osteoarthritis may benefit from healthy patient lifestyles, exercise or activity habits, and daily living routines. Underlying societal issues and social roles may contribute further to both ecological and knee function preservation concerns. Based on sustainability theory and social ecology concepts we propose that factors such as health history, genetic predisposition, socio-environmental factors and local-regional-global physiological system viability contribute to knee function preservation. Addressing only some of these factors or any one factor in isolation can lead the treating physician, surgeon and rehabilitation clinician to less than optimal treatment effectiveness. An example is presented of a 57-year-old man with medial tibiofemoral osteoarthritis. In the intervention decision-making process several factors are important. Patients who would benefit from early knee arthroplasty tend to place osteoarthritic knee pain elimination at the top of their list of treatment expectations. They also have minimal or no desire to continue impact sport, recreational or vocational activities. In contrast, patients who are good candidates for a knee function preservation treatment approach tend to have greater expectations to be able to continue impact sport, recreational or vocational activities, are willing and better able to implement significant behavioral changes and develop the support systems needed for their maintenance, are willing to tolerate and live with minor-to-moderate intermittent knee pain, and learn to become more pain tolerant.

  1. Impact of Soft Tissue Imbalance on Knee Flexion Angle After Posterior Stabilized Total Knee Arthroplasty.

    PubMed

    Tsukada, Sachiyuki; Fujii, Tomoko; Wakui, Motohiro

    2017-08-01

    This study was performed to assess the impact of soft tissue imbalance on the knee flexion angle 2 years after posterior stabilized total knee arthroplasty (TKA). A total of 329 consecutive varus knees were included to assess the association of knee flexion angle 2 years after TKA with preoperative, intraoperative, and postoperative variables. All intraoperative soft tissue measurements were performed by a single surgeon under spinal anesthesia in a standardized manner including the subvastus approach, reduced patella, and without use of a pneumonic tourniquet. Multiple linear regression analysis showed no significant correlations in terms of intraoperative valgus imbalance at 90-degree flexion or the difference in soft tissue tension between 90-degree flexion and 0-degree extension (β = -0.039; 95% confidence interval [CI], -0.88 to 0.80; P = .93 and β = 0.015; 95% CI, -0.29 to 0.32; P = .92, respectively). Preoperative flexion angle was significantly correlated with knee flexion angle 2 years after TKA (β = 0.42; 95% CI, 0.33 to 0.51; P < .0001). Avoiding valgus imbalance at 90-degree flexion and aiming for strictly equal soft tissue tension between 90-degree flexion and 0-degree extension had little practical value with regard to knee flexion angle 2 years after posterior stabilized TKA. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  2. Single-leg hop testing following fatiguing exercise: reliability and biomechanical analysis.

    PubMed

    Augustsson, J; Thomeé, R; Lindén, C; Folkesson, M; Tranberg, R; Karlsson, J

    2006-04-01

    A fatiguing exercise protocol was combined with single-leg hop testing to improve the possibilities of evaluating the effects of training or rehabilitation interventions. In the first test-retest experiment, 11 healthy male subjects performed two trials of single-leg hops under three different test conditions: non-fatigued and following fatiguing exercise, which consisted of unilateral weight machine knee extensions at 80% and 50%, respectively, of 1 repetition maximum (1 RM) strength. Intraclass correlation coefficients ranged from 0.75 to 0.98 for different hop test conditions, indicating that all tests were reliable. For the second experiment, eight healthy male subjects performed the fatiguing exercise protocol to investigate how fatigue influences lower-extremity joint kinematics and kinetics during single-leg hops. Hip, knee and ankle joint angles, moments and powers, as well as ground-reaction forces were recorded with a six-camera, motion-capture system and a force platform. Recovery of hop performance following the fatiguing exercise was also measured. During the take-off for the single-leg hops, hip and knee flexion angles, generated powers for the knee and ankle joints, and ground-reaction forces decreased for the fatigued hop conditions compared with the non-fatigued condition (P<0.05). Compared with landing during the non-fatigued condition, hip moments and ground-reaction forces were lower for the fatigued hop conditions (P<0.05). The negative joint power was two to three times greater for the knee than for the hip and five to 10 times greater for the knee than for the ankle during landing for all test conditions (P<0.05). Most measured variables had recovered three minutes post-exercise. It is concluded that the fatiguing exercise protocol combined with single-leg hop testing was a reliable method for investigating functional performance under fatigued test conditions. Further, subjects utilized an adapted hop strategy, which employed less hip and knee flexion and generated powers for the knee and ankle joints during take-off, and less hip joint moments during landing under fatigued conditions. The large negative power values observed at the knee joint during the landing phase of the single-leg hop, during which the quadriceps muscle activates eccentrically, indicate that not only hop distance but also the ability to perform successful landings should be investigated when assessing dynamic knee function.

  3. Effect of repeated passive anterior loading on human knee anterior laxity.

    PubMed

    Vauhnik, Renata; Perme, Maja Pohar; Barcellona, Massimo G; Morrissey, Matthew C; Sevšek, France; Rugelj, Darja

    2015-10-01

    Increased knee anterior laxity results when the anterior cruciate ligament is injured. This increased laxity can cause knee dysfunction. Until recently this laxity was believed to be only diminished through surgery. But recent findings indicate that knee anterior laxity may be decreased with repeated loading of the knee. The purpose of this study was to test the hypothesis that regular passive anterior loading of the uninjured human knee would enhance its stiffness. Randomized controlled trial. Knee anterior laxity was tested using an arthrometer in 22 young, uninjured females before, during and after a 3 month period during which passive anterior loading was applied by a trained physiotherapist over 5 sessions per week to a randomly assigned knee. Knee anterior laxity was not affected by the passive anterior loading of the knee. Given that in this study repeated passive loading of the knee did not change knee anterior laxity, it would be easy to conclude that this training is ineffective and no further research is required. We caution against this given the relatively short duration and possibly insufficient intensity of the training and the population studied; individuals with normal joint laxity. We recommend that future research be performed that consists of individuals with lax joints who receive training for prolonged periods. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. The Vertical Drop Jump Is a Poor Screening Test for ACL Injuries in Female Elite Soccer and Handball Players: A Prospective Cohort Study of 710 Athletes.

    PubMed

    Krosshaug, Tron; Steffen, Kathrin; Kristianslund, Eirik; Nilstad, Agnethe; Mok, Kam-Ming; Myklebust, Grethe; Andersen, Thor Einar; Holme, Ingar; Engebretsen, Lars; Bahr, Roald

    2016-04-01

    The evidence linking knee kinematics and kinetics during a vertical drop jump (VDJ) to anterior cruciate ligament (ACL) injury risk is restricted to a single small sample. Still, the VDJ test continues to be advocated for clinical screening purposes. To test whether 5 selected kinematic and kinetic variables were associated with future ACL injuries in a large cohort of Norwegian female elite soccer and handball players. Furthermore, we wanted to assess whether the VDJ test can be recommended as a screening test to identify players with increased risk. Cohort study; Level of evidence, 2. Elite female soccer and handball players participated in preseason screening tests from 2007 through 2014. The tests included marker-based 3-dimensional motion analysis of a drop-jump landing. We followed a predefined statistical protocol in which we included the following candidate risk factors in 5 separate logistic regression analyses, with new ACL injury as the outcome: (1) knee valgus angle at initial contact, (2) peak knee abduction moment, (3) peak knee flexion angle, (4) peak vertical ground-reaction force, and (5) medial knee displacement. A total of 782 players were tested (age, 21 ± 4 years; height, 170 ± 7 cm; body mass, 67 ± 8 kg), of which 710 were included in the analyses. We registered 42 new noncontact ACL injuries, including 12 in previously ACL-injured players. Previous ACL injury (relative risk, 3.8; 95% CI, 2.1-7.1) and medial knee displacement (odds ratio, 1.40; 95% CI, 1.12-1.74 per 1-SD change) were associated with increased risk for injury. However, among the 643 players without previous injury, we found no association with medial knee displacement. A receiver operating characteristic curve analysis of medial knee displacement showed an area under the curve of 0.6, indicating a poor-to-failed combined sensitivity and specificity of the test, even when including previously injured players. Of the 5 risk factors considered, medial knee displacement was the only factor associated with increased risk for ACL. However, receiver operating characteristic curve analysis indicated a poor combined sensitivity and specificity when medial knee displacement was used as a screening test for predicting ACL injury. For players with no previous injury, none of the VDJ variables were associated with increased injury risk. VDJ tests cannot predict ACL injuries in female elite soccer and handball players. © 2016 The Author(s).

  5. Short-Term High Intensity Plyometric Training Program Improves Strength, Power and Agility in Male Soccer Players

    PubMed Central

    Váczi, Márk; Tollár, József; Meszler, Balázs; Juhász, Ivett; Karsai, István

    2013-01-01

    The aim of the present study was to investigate the effects of a short-term in-season plyometric training program on power, agility and knee extensor strength. Male soccer players from a third league team were assigned into an experimental and a control group. The experimental group, beside its regular soccer training sessions, performed a periodized plyometric training program for six weeks. The program included two training sessions per week, and maximal intensity unilateral and bilateral plyometric exercises (total of 40 – 100 foot contacts/session) were executed. Controls participated only in the same soccer training routine, and did not perform plyometrics. Depth vertical jump height, agility (Illinois Agility Test, T Agility Test) and maximal voluntary isometric torque in knee extensors using Multicont II dynamometer were evaluated before and after the experiment. In the experimental group small but significant improvements were found in both agility tests, while depth jump height and isometric torque increments were greater. The control group did not improve in any of the measures. Results of the study indicate that plyometric training consisting of high impact unilateral and bilateral exercises induced remarkable improvements in lower extremity power and maximal knee extensor strength, and smaller improvements in soccer-specific agility. Therefore, it is concluded that short-term plyometric training should be incorporated in the in-season preparation of lower level players to improve specific performance in soccer. PMID:23717351

  6. Short-term high intensity plyometric training program improves strength, power and agility in male soccer players.

    PubMed

    Váczi, Márk; Tollár, József; Meszler, Balázs; Juhász, Ivett; Karsai, István

    2013-03-01

    The aim of the present study was to investigate the effects of a short-term in-season plyometric training program on power, agility and knee extensor strength. Male soccer players from a third league team were assigned into an experimental and a control group. The experimental group, beside its regular soccer training sessions, performed a periodized plyometric training program for six weeks. The program included two training sessions per week, and maximal intensity unilateral and bilateral plyometric exercises (total of 40 - 100 foot contacts/session) were executed. Controls participated only in the same soccer training routine, and did not perform plyometrics. Depth vertical jump height, agility (Illinois Agility Test, T Agility Test) and maximal voluntary isometric torque in knee extensors using Multicont II dynamometer were evaluated before and after the experiment. In the experimental group small but significant improvements were found in both agility tests, while depth jump height and isometric torque increments were greater. The control group did not improve in any of the measures. Results of the study indicate that plyometric training consisting of high impact unilateral and bilateral exercises induced remarkable improvements in lower extremity power and maximal knee extensor strength, and smaller improvements in soccer-specific agility. Therefore, it is concluded that short-term plyometric training should be incorporated in the in-season preparation of lower level players to improve specific performance in soccer.

  7. Development of an above-knee prosthesis equipped with a microcomputer-controlled knee joint: first test results.

    PubMed

    Aeyels, B; Peeraer, L; Vander Sloten, J; Van der Perre, G

    1992-05-01

    The shortcomings of conventional above-knee prostheses are due to their lack of adaptive control. Implementation of a microcomputer controlling the knee joint in a passive way has been suggested to enhance the patient's gait comfort, safety and cosmesis. This approach was used in the design of a new prosthetic system for the above-knee amputee, and tested on one patient. The knee joint of a conventional, modular prosthesis was replaced by a knee joint mechanism, equipped with a controllable brake on the knee joint axis. Sensors and a microcomputer were added, keeping the system self-contained. The modularity of the design permits the use of an alternative, external, PC-based control unit, emulating the self-contained one, and offering extended data monitoring and storage facilities. For both units an operating environment was written, including sensor/actuator interfacing and the implementation of a real-time interrupt, executing the control algorithm. A double finite state approach was used in the design of the control algorithm. On a higher level, the mode identification algorithm reveals the patient's intent. Within a specific mode (lower level), the relevant mode control algorithm looks for the current phase within the gait cycle. Within a particular phase, a specific simple control action with the brake replaces normal knee muscle activity. Tests were carried out with one prosthetic patient using a basic control algorithm for level walking, allowing controlled knee flexion during stance phase. The technical feasibility of such a concept is illustrated by the test results, even though only flexion during early stance phase was controlled during the trials.(ABSTRACT TRUNCATED AT 250 WORDS)

  8. A qualitative investigation of the attitudes and beliefs about physical activity and post-traumatic osteoarthritis in young adults 3-10 years after an intra-articular knee injury.

    PubMed

    Ezzat, Allison M; Brussoni, Mariana; Whittaker, Jackie L; Emery, Carolyn A

    2018-05-04

    To understand the influence of the injury experience on current attitudes and beliefs about physical activity (PA) and the development of post-traumatic osteoarthritis (PTOA) in youth and young adults 3-10 years after a sport-related knee injury. Qualitative study. University Sports Medical/Research Center. 20 young adults 3-10 years subsequent to intra-articular knee injury. Semi-structured interviews were conducted and transcribed verbatim. Analysis used a constant comparative approach with conceptual labels and categories, axial coding, and selective coding to reveal main themes. The four main themes were: acceptance; resiliency and determination; knee confidence; and athletic identity. Participants accepted the impact of the injury on their sporting ability and future PTOA to varying degrees. Participants were often highly motivated to recover and met the injury with resilience. Knee confidence was a major concern. Most participants' athletic identity had evolved; impacted both by life and injury experiences. This study provides insight into the knee injury experience and resultant attitudes and beliefs regarding PA and PTOA in adolescents. Physiotherapists may assist in secondary prevention of PTOA by promoting PA, addressing knee confidence, and educating about long-term joint health. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Validation of a computational knee joint model using an alignment method for the knee laxity test and computed tomography.

    PubMed

    Kang, Kyoung-Tak; Kim, Sung-Hwan; Son, Juhyun; Lee, Young Han; Koh, Yong-Gon

    2017-01-01

    Computational models have been identified as efficient techniques in the clinical decision-making process. However, computational model was validated using published data in most previous studies, and the kinematic validation of such models still remains a challenge. Recently, studies using medical imaging have provided a more accurate visualization of knee joint kinematics. The purpose of the present study was to perform kinematic validation for the subject-specific computational knee joint model by comparison with subject's medical imaging under identical laxity condition. The laxity test was applied to the anterior-posterior drawer under 90° flexion and the varus-valgus under 20° flexion with a series of stress radiographs, a Telos device, and computed tomography. The loading condition in the computational subject-specific knee joint model was identical to the laxity test condition in the medical image. Our computational model showed knee laxity kinematic trends that were consistent with the computed tomography images, except for negligible differences because of the indirect application of the subject's in vivo material properties. Medical imaging based on computed tomography with the laxity test allowed us to measure not only the precise translation but also the rotation of the knee joint. This methodology will be beneficial in the validation of laxity tests for subject- or patient-specific computational models.

  10. Knee joint kinematics after dynamic intraligamentary stabilization: cadaveric study on a novel anterior cruciate ligament repair technique.

    PubMed

    Schliemann, Benedikt; Lenschow, Simon; Domnick, Christoph; Herbort, Mirco; Häberli, Janosch; Schulze, Martin; Wähnert, Dirk; Raschke, Michael J; Kösters, Clemens

    2017-04-01

    Dynamic intraligamentary stabilization (DIS) has been introduced for the repair of acute anterior cruciate ligament (ACL) tears as an alternative to delayed reconstruction. The aim of the present study was to compare knee joint kinematics after DIS to those of the ACL-intact and ACL-deficient knee under simulated Lachman/KT-1000 and pivot-shift tests. We hypothesized that DIS provides knee joint kinematics equivalent to an intact ACL. With the use of a robotic knee simulator, knee kinematics were determined in simulated Lachman/KT-1000 and pivot-shift tests at 0°, 15°, 30°, 60°, and 90° of flexion in eight cadaveric knees under the following conditions: (1) intact ACL, (2) ACL deficiency, (3) DIS with a preload of 60 N, and (4) DIS with a preload of 80 N. Statistical analyses were performed using two-factor repeated-measures analysis of variance. The significance level was set at a p value of <0.05. After DIS with a preload of either 60 N or 80 N, the anterior translation was significantly reduced in the simulated Lachman/KT-1000 and pivot-shift tests when compared to the ACL-deficient knee (p < 0.05). No significant differences were observed between the DIS reconstruction with a preload of 80 N and the intact ACL with regard to anterior laxity in either test. However, DIS with a preload of only 60 N was not able to restore knee joint kinematics to that of an intact knee in all degrees of flexion. DIS with a preload of 80 N restores knee joint kinematics comparable to that of an ACL-intact knee and is therefore capable of providing knee joint stability during ACL healing. DIS therefore provides a new technique for primary ACL repair with superior biomechanical properties in comparison with other techniques that have been described previously, although further clinical studies are required to determine its usefulness in clinical settings.

  11. Finite element analysis of the valgus knee joint of an obese child.

    PubMed

    Sun, Jun; Yan, Songhua; Jiang, Yan; Wong, Duo Wai-Chi; Zhang, Ming; Zeng, Jizhou; Zhang, Kuan

    2016-12-28

    Knee valgus and varus morbidity is at the second top place in children lower limb deformity diseases. It may cause abnormal stress distribution. The magnitude and location of contact forces on tibia plateau during gait cycle have been indicated as markers for risk of osteoarthritis. So far, few studies reported the contact stress and force distribution on tibial plateau of valgus knee of children. To estimate the contact stresses and forces on tibial plateau of an 8-year old obese boy with valgus knee and a 7-year old healthy boy, three-dimensional (3D) finite element (FE) models of their left knee joints were developed. The valgus knee model has 36,897 nodes and 1,65,106 elements, and the normal knee model has 78,278 nodes and 1,18,756 elements. Paired t test was used for the comparison between the results from the 3D FE analysis method and the results from traditional kinematic measurement methods. The p value of paired t test is 0.12. Maximum stresses shifted to lateral plateau in knee valgus children while maximum stresses were on medial plateau in normal knee child at the first peak of vertical GRF of stance phase. The locations of contact centers on medial plateau changed 3.38 mm more than that on lateral plateau, while the locations of contact centers on medial plateau changed 1.22 mm less than that on lateral plateau for healthy child from the first peak to second peak of vertical GRF of stance phase. The paired t test result shows that there is no significant difference between the two methods. The results of FE analysis method suggest that knee valgus malalignment could be the reason for abnormal knee load that may cause knee problems in obese children with valgus knee in the long-term. This study may help to understand biomechanical mechanism of valgus knees of obese children.

  12. Objectivity, Reliability, and Validity of the Bent-Knee Push-Up for College-Age Women

    ERIC Educational Resources Information Center

    Wood, Heather M.; Baumgartner, Ted A.

    2004-01-01

    The revised push-up test has been found to have good validity but it produces many zero scores for women. Maybe there should be an alternative to the revised push-up test for college-age women. The purpose of this study was to determine the objectivity, reliability, and validity for the bent-knee push-up test (executed on hands and knees) for…

  13. Can joint sound assess soft and hard endpoints of the Lachman test?: A preliminary study.

    PubMed

    Hattori, Koji; Ogawa, Munehiro; Tanaka, Kazunori; Matsuya, Ayako; Uematsu, Kota; Tanaka, Yasuhito

    2016-05-12

    The Lachman test is considered to be a reliable physical examination for anterior cruciate ligament (ACL) injury. Patients with a damaged ACL demonstrate a soft endpoint feeling. However, examiners judge the soft and hard endpoints subjectively. The purpose of our study was to confirm objective performance of the Lachman test using joint auscultation. Human and porcine knee joints were examined. Knee joint sound during the Lachman test (Lachman sound) was analyzed by fast Fourier transformation. As quantitative indices of Lachman sound, the peak sound as the maximum relative amplitude (acoustic pressure) and its frequency were used. The mean Lachman peak sound for healthy volunteer knees was 86.9 ± 12.9 Hz in frequency and -40 ± 2.5 dB in acoustic pressure. The mean Lachman peak sound for intact porcine knees was 84.1 ± 9.4 Hz and -40.5 ± 1.7 dB. Porcine knees with ACL deficiency had a soft endpoint feeling during the Lachman test. The Lachman peak sounds of porcine knees with ACL deficiency were dispersed into four distinct groups, with center frequencies of around 40, 160, 450, and 1600. The Lachman peak sound was capable of assessing soft and hard endpoints of the Lachman test objectively.

  14. Association of radiographic and symptomatic knee osteoarthritis with health-related quality of life in a population-based cohort study in Japan: the ROAD study.

    PubMed

    Muraki, S; Akune, T; Oka, H; En-yo, Y; Yoshida, M; Saika, A; Suzuki, T; Yoshida, H; Ishibashi, H; Tokimura, F; Yamamoto, S; Nakamura, K; Kawaguchi, H; Yoshimura, N

    2010-09-01

    Knee osteoarthritis (OA) is a major public health issue causing chronic pain and disability. However, there is little information on the impact of this disease on quality of life (QOL) in Japanese men and women. The objective of the present study was to clarify the impact of radiographic and symptomatic knee OA on QOL in Japan. This study examined the association of radiographic and symptomatic knee OA with QOL parameters such as the Medical Outcomes Study Short Form-8 (SF-8), EuroQOL (EQ-5D) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Radiographic knee OA was defined according to Kellgren/Lawrence (KL) grades, and symptomatic knee OA was defined as KL=3 or 4 with knee pain. We also examined the independent association of symptomatic knee OA and grip strength with QOL. From the 3040 participants in the Research on Osteoarthritis Against Disability (ROAD) study, the present study analyzed 2126 subjects older than 40 years who completed the questionnaires (767 men and 1359 women; mean age, 68.9+/-10.9 years). Subjects with KL=3 or 4 had significantly lower physical QOL as measured by the physical component summary (PCS) score of the SF-8 and pain domains of the WOMAC, whereas mental QOL, as measured by the mental component summary (MCS) score of the SF-8, was higher in subjects with KL=3 or 4 than KL=0 or 1. Symptomatic knee OA was significantly more likely than radiographic knee OA without pain to be associated with physical QOL loss as measured by the PCS score and physical domains of the WOMAC. Symptomatic knee OA and grip strength were independently associated with physical QOL. This cross-sectional study revealed that subjects with symptomatic knee OA had significantly lower physical QOL than subjects without it. Copyright 2010 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  15. Sensitivity and specificity of the 'knee-up test' for estimation of the American Spinal Injury Association Impairment Scale in patients with acute motor incomplete cervical spinal cord injury.

    PubMed

    Yugué, Itaru; Okada, Seiji; Maeda, Takeshi; Ueta, Takayoshi; Shiba, Keiichiro

    2018-04-01

    A retrospective study. Precise classification of the neurological state of patients with acute cervical spinal cord injury (CSCI) can be challenging. This study proposed a useful and simple clinical method to help classify patients with incomplete CSCI. Spinal Injuries Centre, Japan. The sensitivity and specificity of the 'knee-up test' were evaluated in patients with acute CSCI classified as American Spinal Injury Association Impairment Scale (AIS) C or D. The result is positive if the patient can lift the knee in one or both legs to an upright position, whereas the result is negative if the patient is unable to lift the knee in either leg to an upright position. The AIS of these patients was classified according to a strict computerised algorithm designed by Walden et al., and the knee-up test was tested by non-expert examiners. Among the 200 patients, 95 and 105 were classified as AIS C and AIS D, respectively. Overall, 126 and 74 patients demonstrated positive and negative results, respectively, when evaluated using the knee-up test. A total of 104 patients with positive results and 73 patients with negative results were classified as AIS D and AIS C, respectively. The sensitivity, specificity, positive predictive and negative predictive values of this test for all patients were 99.1, 76.8, 82.5 and 98.7, respectively. The knee-up test may allow easy and highly accurate estimation, without the need for special skills, of AIS classification for patients with incomplete CSCI.

  16. Medial-to-lateral Ratio of Tibiofemoral Subchondral Bone Area is Adapted to Alignment and Mechanical Load

    PubMed Central

    Eckstein, Felix; Hudelmaier, Martin; Cahue, September; Marshall, Meredith; Sharma, Leena

    2010-01-01

    Malalignment is known to impact the medial-to-lateral load distribution in the tibiofemoral joint. In this longitudinal study, we test the hypothesis that subchondral bone surface areas functionally adapt to the load distribution in malaligned knees. Alignment (hip-knee-ankle angle) was measured from full limb films in 174 participants with knee osteoarthritis. Coronal MR images were acquired at baseline and 26.6±5.4 months later. The subchondral bone surface area of the weight-bearing tibiofemoral cartilages was segmented, with readers blinded to the order of acquisition. The size of the subchondral bone surface areas was computed after triangulation using proprietary software. The hip-knee-ankle angle showed a significant correlation with the tibial (r2=0.25, p<0.0001) and femoral (r2=0.07, p<0.001) ratio of medial-to-lateral subchondral bone surface area. In the tibia, the ratio was significantly different between varus (1.28:1), neutral (1.18:1) and valgus (1.13:1) knees (ANOVA; p<0.00001). Similar observations were made in the weight-bearing femur (0.94:1 in neutral, 0.97.1 in varus, 0.91:1 in valgus knees; ANOVA p=0.018). The annualized longitudinal increase in subchondral bone surface area was significant (p<0.05) in the medial tibia (+0.13%), medial femur (+0.26%) and lateral tibia (+0.19%). In the medial femur, the change between baseline and follow-up was significantly different (ANOVA; p=0.020) between neutral, varus and valgus knees, the increase in surface area being significantly greater (p=0.019) in varus than in neutral knees. Tibiofemoral subchondral bone surface areas are shown to be functionally adapted to the medial-to-lateral load distribution. The longitudinal findings indicate that this adaptational process may continue to take place at advanced age. PMID:19148562

  17. A statistically compiled test battery for feasible evaluation of knee function after rupture of the Anterior Cruciate Ligament - derived from long-term follow-up data.

    PubMed

    Schelin, Lina; Tengman, Eva; Ryden, Patrik; Häger, Charlotte

    2017-01-01

    Clinical test batteries for evaluation of knee function after injury to the Anterior Cruciate Ligament (ACL) should be valid and feasible, while reliably capturing the outcome of rehabilitation. There is currently a lack of consensus as to which of the many available assessment tools for knee function that should be included. The present aim was to use a statistical approach to investigate the contribution of frequently used tests to avoid redundancy, and filter them down to a proposed comprehensive and yet feasible test battery for long-term evaluation after ACL injury. In total 48 outcome variables related to knee function, all potentially relevant for a long-term follow-up, were included from a cross-sectional study where 70 ACL-injured (17-28 years post injury) individuals were compared to 33 controls. Cluster analysis and logistic regression were used to group variables and identify an optimal test battery, from which a summarized estimator of knee function representing various functional aspects was derived. As expected, several variables were strongly correlated, and the variables also fell into logical clusters with higher within-correlation (max ρ = 0.61) than between clusters (max ρ = 0.19). An extracted test battery with just four variables assessing one-leg balance, isokinetic knee extension strength and hop performance (one-leg hop, side hop) were mathematically combined to an estimator of knee function, which acceptably classified ACL-injured individuals and controls. This estimator, derived from objective measures, correlated significantly with self-reported function, e.g. Lysholm score (ρ = 0.66; p<0.001). The proposed test battery, based on a solid statistical approach, includes assessments which are all clinically feasible, while also covering complementary aspects of knee function. Similar test batteries could be determined for earlier phases of ACL rehabilitation or to enable longitudinal monitoring. Such developments, established on a well-grounded consensus of measurements, would facilitate comparisons of studies and enable evidence-based rehabilitation.

  18. Stance control knee mechanism for lower-limb support in hybrid neuroprosthesis

    PubMed Central

    To, Curtis S.; Kobetic, Rudi; Bulea, Thomas C.; Audu, Musa L.; Schnellenberger, John R.; Pinault, Gilles; Triolo, Ronald J.

    2014-01-01

    A hydraulic stance control knee mechanism (SCKM) was developed to fully support the knee against flexion during stance and allow uninhibited motion during swing for individuals with paraplegia using functional neuromuscular stimulation (FNS) for gait assistance. The SCKM was optimized for maximum locking torque for body-weight support and minimum resistance when allowing for free knee motion. Ipsilateral and contralateral position and force feedback were used to control the SCKM. Through bench and nondisabled testing, the SCKM was shown to be capable of supporting up to 70 N-m, require no more than 13% of the torque achievable with FNS to facilitate free motion, and responsively and repeatedly unlock under an applied flexion knee torque of up to 49 N-m. Preliminary tests of the SCKM with an individual with paraplegia demonstrated that it could support the body and maintain knee extension during stance without the stimulation of the knee extensor muscles. This was achieved without adversely affecting gait, and knee stability was comparable to gait assisted by knee extensor stimulation during stance. PMID:21938668

  19. Enhancement of a prosthetic knee with a microprocessor-controlled gait phase switch reduces falls and improves balance confidence and gait speed in community ambulators with unilateral transfemoral amputation.

    PubMed

    Fuenzalida Squella, Sara Agueda; Kannenberg, Andreas; Brandão Benetti, Ângelo

    2018-04-01

    Despite the evidence for improved safety and function of microprocessor stance and swing-controlled prosthetic knees, non-microprocessor-controlled prosthetic knees are still standard of care for persons with transfemoral amputations in most countries. Limited feature microprocessor-control enhancement of such knees could stand to significantly improve patient outcomes. To evaluate gait speed, balance, and fall reduction benefits of the new 3E80 default stance hydraulic knee compared to standard non-microprocessor-controlled prosthetic knees. Comparative within-subject clinical study. A total of 13 young, high-functioning community ambulators with a transfemoral amputation underwent assessment of performance-based (e.g. 2-min walk test, timed ramp/stair tests) and self-reported (e.g. falls, Activities-Specific Balance Confidence scale, Prosthesis Evaluation Questionnaire question #1, Satisfaction with the Prosthesis) outcome measures for their non-microprocessor-controlled prosthetic knees and again after 8 weeks of accommodation to the 3E80 microprocessor-enhanced knee. Self-reported falls significantly declined 77% ( p = .04), Activities-Specific Balance Confidence scores improved 12 points ( p = .005), 2-min walk test walking distance increased 20 m on level ( p = .01) and uneven ( p = .045) terrain, and patient satisfaction significantly improved ( p < .01) when using the 3E80 knee. Slope and stair ambulation performance did not differ between knee conditions. The 3E80 knee reduced self-reported fall incidents and improved balance confidence. Walking performance on both level and uneven terrains also improved compared to non-microprocessor-controlled prosthetic knees. Subjects' satisfaction was significantly higher than with their previous non-microprocessor-controlled prosthetic knees. The 3E80 may be considered a prosthetic option for improving gait performance, balance confidence, and safety in highly active amputees. Clinical relevance This study compared performance-based and self-reported outcome measures when using non-microprocessor and a new microprocessor-enhanced, default stance rotary hydraulic knee. The results inform rehabilitation professionals about the functional benefits of a limited-feature, microprocessor-enhanced hydraulic prosthetic knee over standard non-microprocessor-controlled prosthetic knees.

  20. How does knee pain affect trunk and knee motion during badminton forehand lunges?

    PubMed

    Huang, Ming-Tung; Lee, Hsing-Hsan; Lin, Cheng-Feng; Tsai, Yi-Ju; Liao, Jen-Chieh

    2014-01-01

    Badminton requires extensive lower extremity movement and a precise coordination of the upper extremity and trunk movements. Accordingly, this study investigated motions of the trunk and the knee, control of dynamic stability and muscle activation patterns of individuals with and without knee pain. Seventeen participants with chronic knee pain and 17 healthy participants participated in the study and performed forehand forward and backward diagonal lunges. This study showed that those with knee pain exhibited smaller knee motions in frontal and horizontal planes during forward lunge but greater knee motions in sagittal plane during backward lunge. By contrast, in both tasks, the injured group showed a smaller value on the activation level of the paraspinal muscles in pre-impact phase, hip-shoulder separation angle, trunk forward inclination range and peak centre of mass (COM) velocity. Badminton players with knee pain adopt a more conservative movement pattern of the knee to minimise recurrence of knee pain. The healthy group exhibit better weight-shifting ability due to a greater control of the trunk and knee muscles. Training programmes for badminton players with knee pain should be designed to improve both the neuromuscular control and muscle strength of the core muscles and the knee extensor with focus on the backward lunge motion.

  1. Effect of surgical closing in total knee arthroplasty at flexion or extension: a prospective, randomized study.

    PubMed

    Kömürcü, Erkam; Yüksel, Halil Yalçın; Ersöz, Murat; Aktekin, Cem Nuri; Hapa, Onur; Çelebi, Levent; Akbal, Ayla; Biçimoğlu, Ali

    2014-12-01

    The aim of this study was to evaluate the effect of knee position during wound closure (flexed vs. extended) in total knee arthroplasty on knee strength and function, as determined by knee society scores and isokinetic testing of extensor and flexor muscle groups. In a prospective, randomized, double-blind trial, 29 patients were divided in two groups: for Group 1 patients, surgical closing was performed with the knee extended, and for Group 2 patients, the knee flexed at 90°. All the patients were treated with the same anaesthesia method, surgical team, surgical technique, prosthesis type, and rehabilitation process. American Knee Society Score values and knee flexion degrees were recorded. Isokinetic muscle strength measurements of both knees in flexion and extension were taken using 60° and 180°/s angular velocity. The peak torque and total work values, isokinetic muscle strength differences, and total work difference values were calculated for surgically repaired and healthy knees. No significant difference in the mean American Knee Society Score values and knee flexion degrees was observed between the two groups. However, using isokinetic evaluation, a significant difference was found in the isokinetic muscle strength differences and total work difference of the flexor muscle between the two groups when patients were tested at 180°/s. Less loss of strength was detected in the isokinetic muscle strength differences of the flexor muscle in Group 2 (-4.2%) than in Group 1 (-23.1%). For patients undergoing total knee arthroplasty, post-operative flexor muscle strength is improved if the knee is flexed during wound closure. II.

  2. Computational Knee Ligament Modeling Using Experimentally Determined Zero-Load Lengths

    PubMed Central

    Bloemker, Katherine H; Guess, Trent M; Maletsky, Lorin; Dodd, Kevin

    2012-01-01

    This study presents a subject-specific method of determining the zero-load lengths of the cruciate and collateral ligaments in computational knee modeling. Three cadaver knees were tested in a dynamic knee simulator. The cadaver knees also underwent manual envelope of motion testing to find their passive range of motion in order to determine the zero-load lengths for each ligament bundle. Computational multibody knee models were created for each knee and model kinematics were compared to experimental kinematics for a simulated walk cycle. One-dimensional non-linear spring damper elements were used to represent cruciate and collateral ligament bundles in the knee models. This study found that knee kinematics were highly sensitive to altering of the zero-load length. The results also suggest optimal methods for defining each of the ligament bundle zero-load lengths, regardless of the subject. These results verify the importance of the zero-load length when modeling the knee joint and verify that manual envelope of motion measurements can be used to determine the passive range of motion of the knee joint. It is also believed that the method described here for determining zero-load length can be used for in vitro or in vivo subject-specific computational models. PMID:22523522

  3. [CLINICAL OBSERVATION OF ONE-STAGE ARTHROSCOPIC RECONSTRUCTION AND STRICT IMMOBILIZATION FOR TREATMENT OF KNEE DISLOCATION].

    PubMed

    Mamatkerimulla; Xu Gang; Wang, Xin; Zhang, Yang; Jia, Yong; Huang, Tao; Xing, Shuxing

    2016-04-01

    To investigate the effectiveness of one-stage arthroscopic reconstruction and strict immobilization for 6 weeks for treatment of knee dislocation. Between August 2010 and May 2013, 22 cases (22 knees) of knee dislocation were treated with one-stage reconstruction and strict immobilization for 6 weeks. There were 15 males and 7 females, aged 21-54 years (mean, 31.5 years). The left knee and right knee were involved in 8 cases and 14 cases respectively. The disease causes were traffic accident in 12 cases, falling from height in 6 cases, and sports injury in 4 cases. The time between injury and operation was less than 2 weeks in 6 cases, 2-3 weeks in 10 cases, and more than 3 weeks in 6 cases. The results of anterior drawer test, posterior drawer test, and Lachman test were positive in all patients. The posterior displacement of the tibia was more than 10 mm. The results of valgus stress test and varus stress test were positive in 13 cases and 11 cases respectively. The preoperative knee range of motion was (58.2 ± 28.4)°, Lysholm score was 39.7 ± 4.6. All patients had anterior cruciate ligament rupture and posterior cruciate ligament rupture; combined injuries included medial collateral ligament rupture in 11 cases, lateral collateral ligament rupture in 9 cases, both medial and lateral collateral ligament rupture in 2 cases, femoral condylar avulsion fracture in 2 cases, and meniscus injury in 7 cases. No nerve or blood vessel injury was observed. All cases obtained primary healing of incision without infection. All the patients were followed up 12-48 months (mean, 27.8 months). At 12 months after operation, the results of the anterior drawer test, posterior drawer test, Lachman test, valgus stress test, and varus stress test were all negative; the knee range of motion increased was significantly to (121.3 ± 7.9)° (t = 30.061, P = 0.000); Lysholm score was 87.2 ± 6.1, showing significant difference when compared with preoperative score (t = 24.642, P = 0.000). A combination oathogopi osta ge reconstruction and strict immobilization for treatment of knee dislocation is a safe and effective method, good stability and joint function can be achieved.

  4. Correlation of the Y-Balance Test with Lower-limb Strength of Adult Women

    PubMed Central

    Lee, Dong-Kyu; Kim, Gyoung-Mo; Ha, Sung-Min; Oh, Jae-Seop

    2014-01-01

    [Purpose] The purpose of this study was to elucidate the relationship between Y-balance test (YBT) distance and the lower-limb strength of adult women. [Subjects] Forty women aged 45 to 80 years volunteered for this study. [Methods] The participants were tested for maximal muscle strength of the lower limbs (hip extensors, hip flexors, hip abductors, knee extensors, knee flexors, and ankle dorsiflexors) and YBT distances in the anterior, posteromedial, and posterolateral directions. Pearson’s correlation coefficient was used to quantify the linear relationships between YBT distances and lower-limb strength. [Results] Hip extensor and knee flexor strength were positively correlated with YBT anterior distance. Hip extensor, hip abductor, and knee flexor strength were positively correlated with the YBT posteromedial distance. Hip extensor and knee flexor strength were positively correlated with YBT posterolateral distance. [Conclusion] There was a weak correlation between lower-limb strength (hip extensors, hip abductors, and knee flexors) and dynamic postural control as measured by the YBT. PMID:24926122

  5. Gains in flexibility related to measures of muscular performance: impact of flexibility on muscular performance.

    PubMed

    Ferreira, Gustavo Nunes Tasca; Teixeira-Salmela, Luci Fuscaldi; Guimarães, Cristiano Queiroz

    2007-07-01

    Studies that investigated possible correlations between flexibility and muscular performance are scarce in the literature. Therefore, the purpose of this study was to investigate the impact of a program of static stretching on the flexibility of the hamstrings and on muscular performance of the knee flexors and extensors. Pre-post experimental design. University laboratory. Thirty subjects aged 22.8 +/- 4.9 years with bilaterally shortened hamstrings. Using a protocol that has been previously described, the intervention consisted of 30 sessions of static stretching, performed bilaterally five times a week for 6 weeks. Measures of knee range of motion and isokinetic muscular performance (peak torque, angle of peak torque, and work) of knee flexors and extensors at speeds of 60 and 300 degrees/s. After intervention, significant gains in measures of flexibility (P < 0.0001) were observed, with an average gain of the knee-extension angle of 12.6 degrees, ranging from -1.2 to 30.7 degrees. In addition, we found significant increases in the following parameters of muscular performance: angle of peak torque of hamstrings at 60 and 300 degrees/s (P < 0.0001 and 0.018) and for work at 60 and 300 degrees/s for knee flexors (P = 0.012 and 0.005) and for knee extensors (P < 0.0001). The intervention resulted in gains in measures of flexibility, and these gains had a positive impact on some parameters of muscular performance.

  6. Rapid Prototyping for In Vitro Knee Rig Investigations of Prosthetized Knee Biomechanics: Comparison with Cobalt-Chromium Alloy Implant Material

    PubMed Central

    Schröder, Christian; Steinbrück, Arnd; Müller, Tatjana; Woiczinski, Matthias; Chevalier, Yan; Müller, Peter E.; Jansson, Volkmar

    2015-01-01

    Retropatellar complications after total knee arthroplasty (TKA) such as anterior knee pain and subluxations might be related to altered patellofemoral biomechanics, in particular to trochlear design and femorotibial joint positioning. A method was developed to test femorotibial and patellofemoral joint modifications separately with 3D-rapid prototyped components for in vitro tests, but material differences may further influence results. This pilot study aims at validating the use of prostheses made of photopolymerized rapid prototype material (RPM) by measuring the sliding friction with a ring-on-disc setup as well as knee kinematics and retropatellar pressure on a knee rig. Cobalt-chromium alloy (standard prosthesis material, SPM) prostheses served as validation standard. Friction coefficients between these materials and polytetrafluoroethylene (PTFE) were additionally tested as this latter material is commonly used to protect pressure sensors in experiments. No statistical differences were found between friction coefficients of both materials to PTFE. UHMWPE shows higher friction coefficient at low axial loads for RPM, a difference that disappears at higher load. No measurable statistical differences were found in knee kinematics and retropatellar pressure distribution. This suggests that using polymer prototypes may be a valid alternative to original components for in vitro TKA studies and future investigations on knee biomechanics. PMID:25879019

  7. Forced knee extension test is a manual test that correlates with the unstable feelings of patients with ACL injury before and after reconstruction.

    PubMed

    Shirasawa, Shinichi; Koga, Hideyuki; Horie, Masafumi; Nakamura, Tomomasa; Watanabe, Toshifumi; Sekiya, Ichiro; Muneta, Takeshi

    2016-12-01

    To investigate fear in patients with anterior cruciate ligament (ACL) injury before and after reconstruction, a forced knee extension (FKE) test was performed. The correlation of the test results was evaluated with the subjective function, sports performance and objective parameters. The study included 102 patients with unilateral ACL reconstruction using a semitendinosus tendon with full clinical evaluation. This study was retrospective and determined the longitudinal results of the FKE test and investigated the effects on the subjective and objective outcomes at 2years. Preoperatively, 47% of patients showed positive FKE tests. The number of positive FKE tests was 31% at six months and 15% at 24months after ACL reconstruction. At two years, there were statistically significant differences between the FKE test positives and negatives regarding both subjective knee recovery (P=0.0095) and sports performance (P=0.0006). A new manual test, called the forced knee extension test, for fear in patients with ACL injury before and after reconstruction was introduced. The apprehension remained positive in 15% of the patients two years after ACL reconstruction, which affected subjective recovery of knee function and sports performance. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Functional Performance Among Active Female Soccer Players After Unilateral Primary Anterior Cruciate Ligament Reconstruction Compared With Knee-Healthy Controls.

    PubMed

    Fältström, Anne; Hägglund, Martin; Kvist, Joanna

    2017-02-01

    Good functional performance with limb symmetry is believed to be important to minimize the risk of injury after a return to pivoting and contact sports after anterior cruciate ligament reconstruction (ACLR). This study aimed to investigate any side-to-side limb differences in functional performance and movement asymmetries in female soccer players with a primary unilateral anterior cruciate ligament (ACL)-reconstructed knee and to compare these players with knee-healthy controls from the same soccer teams. Cross-sectional study; Level of evidence, 3. This study included 77 active female soccer players at a median of 18 months after ACLR (interquartile range [IQR], 14.5 months; range, 7-39 months) and 77 knee-healthy female soccer players. The mean age was 20.1 ± 2.3 years for players with an ACL-reconstructed knee and 19.5 ± 2.2 years for controls. We used a battery of tests to assess postural control (Star Excursion Balance Test) and hop performance (1-legged hop for distance, 5-jump test, and side hop). Movement asymmetries in the lower limbs and trunk were assessed with the drop vertical jump and the tuck jump using 2-dimensional analyses. The reconstructed and uninvolved limbs did not differ in any of the tests. In the 5-jump test, players with an ACL-reconstructed knee performed worse than controls (mean 8.75 ± 1.05 m vs 9.09 ± 0.89 m; P = .034). On the drop vertical jump test, the ACL-reconstructed limb had significantly less knee valgus motion in the frontal plane (median 0.028 m [IQR, 0.049 m] vs 0.045 m [IQR, 0.043 m]; P = .004) and a lower probability of a high knee abduction moment (pKAM) (median 69.2% [IQR, 44.4%] vs 79.8% [IQR, 44.8%]; P = .043) compared with the control players' matched limb (for leg dominance). Results showed that 9% to 49% of players in both groups performed outside recommended guidelines on the different tests. Only 14 players with an ACL-reconstructed knee (18%) and 15 controls (19%) had results that met the recommended guidelines for all 5 tests ( P = .837). The reconstructed and uninvolved limbs did not differ, and players with an ACL-reconstructed knee and controls differed only minimally on the functional performance tests, indicating similar function. It is worth noting that many players with an ACL-reconstructed knee and controls had movement asymmetries and a high pKAM pattern, which have previously been associated with an increased risk for both primary and secondary ACL injury in female athletes.

  9. Treating knee pain: history taking and accurate diagnoses.

    PubMed

    Barratt, Julian

    2010-07-01

    Prompt and effective diagnosis and treatment for common knee problems depend on practitioners' ability to distinguish between traumatic and inflammatory knee conditions. This article aims to enable practitioners to make accurate assessments, carry out knee examinations and undertake selected special tests as necessary before discharging or referring patients.

  10. Knee crepitus is prevalent in women with patellofemoral pain, but is not related with function, physical activity and pain.

    PubMed

    de Oliveira Silva, Danilo; Pazzinatto, Marcella Ferraz; Priore, Liliam Barbuglio Del; Ferreira, Amanda Schenatto; Briani, Ronaldo Valdir; Ferrari, Deisi; Bazett-Jones, David; Azevedo, Fábio Mícolis de

    2018-06-06

    (i) To assess the reliability of knee crepitus measures, (ii) to investigate the association between knee crepitus and PFP; (iii) to investigate the relationship between knee crepitus with self-reported function, physical activity and pain. Cross-sectional. Laboratory-based study. 165 women with PFP and 158 pain-free women. Knee crepitus test, anterior knee pain scale (AKPS) and self-reported worst knee pain in the last month, knee pain after 10 squats and knee pain after 10 stairs climbing. Knee crepitus clinical test presented high reliability Kappa value for PFP group was 0.860 and for pain-free group was 0.906. There is a significantly greater proportion of those with crepitus in the PFP group than in the pain-free group (OR = 4.19). Knee crepitus had no relationship with function (rpb = 0.03; p = 0.727), physical activity level (rpb = 0.010; p = 0.193), worst pain (rpb = 0.11; p = 0.141), pain climbing stairs (rpb = 0.10; p = 0.194) and pain squatting (rpb = 0.02; p = 0.802). Women who presents knee crepitus have 4 times greater odds to be in a group with PFP compared to those who do not. However, knee crepitus has no relationship with self-reported clinical outcomes of women with PFP. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. The effects of a supportive knee brace on leg performance in healthy subjects.

    PubMed

    Veldhuizen, J W; Koene, F M; Oostvogel, H J; von Thiel, T P; Verstappen, F T

    1991-12-01

    Eight healthy volunteers were fitted with a supportive knee brace (Push Brace 'Heavy') to one knee for a duration of four weeks wherein they were tested before, during and after the application to establish the effect of bracing on performance. The tests consisted of isokinetic strength measurement of knee flexion and extension, 60 meter dash, vertical jump height and a progressive horizontal treadmill test until exhaustion (Vmax) with determination of oxygen uptake, heart rate and plasma lactate concentration. Wearing the brace for one day, the performance indicators showed a decline compared with the test before application (base values). Sprint time was 4% longer (p less than 0.01) and Vmax 6% slower (p less than 0.01). Peak torque of knee flexion at 60 and 240 deg.sec-1 was 6% (p less than 0.05) respectively 9% (p less than 0.05) less. Peak extension torque at 60 deg.sec-1 was 9% less (p less than 0.05). While wearing the brace for four weeks, the test performances were practically identical to their base values. After removal of the brace, all test parameters were statistically similar to the base values. Heart rate at submaximal exercise levels was even lower (p less than 0.05). In conclusion, performance in sports with test-like exercise patterns is not affected by the brace tested. Bracing does not "weaken the knee" as it is widely believed in sports practice.

  12. Reliability of a device for the knee and ankle isometric and isokinetic strength testing in older adults.

    PubMed

    Bergamin, Marco; Gobbo, Stefano; Bullo, Valentina; Vendramin, Barbara; Duregon, Federica; Frizziero, Antonio; Di Blasio, Andrea; Cugusi, Lucia; Zaccaria, Marco; Ermolao, Andrea

    2017-01-01

    Lower extremity muscle mass, strength, power, and physical performance are critical determinants of independent functioning in later life. Isokinetic dynamometers are becoming very common in assessing different features of muscle strength, in both research and clinical practice; however, reliability studies are still needed to support the extended use of those devices. The purpose of this study is to assess the test-retest reliability of knee and ankle isokinetic and isometric strength testing protocols in a sample of older healthy subjects, using a new and untested isokinetic multi-joint evaluation system. Sixteen male and fourteen female older adults (mean age 65.2 ± 4.6 years) were assessed in two testing sessions. Each participant performed a randomized testing procedure that includes different isometric and isokinetic tests for knee and ankle joints. All participants concluded the trial safety and no subject reported any discomfort throughout the overall assessment. Coefficients of correlation between measures were calculated showing moderate to strong effects among all test-retest assessments and paired-sample t test showed only one significant difference (p<0.05) in the maximal isokinetic bilateral knee flexion torque. The multi-joint evaluation system for the assessment of knee and ankle isokinetic and isometric strength provided reliable test-retest measures in healthy older adults. Ib.

  13. Balance and Risk of Fall in Individuals with Bilateral Mild and Moderate Knee Osteoarthritis

    PubMed Central

    Khalaj, Nafiseh; Abu Osman, Noor Azuan; Mokhtar, Abdul Halim; Mehdikhani, Mahboobeh; Wan Abas, Wan Abu Bakar

    2014-01-01

    Balance is essential for mobility and performing activities of daily living. People with knee osteoarthritis display impairment in knee joint proprioception. Thus, the aim of this study was to evaluate balance and risk of fall in individuals with bilateral mild and moderate knee osteoarthritis. Sixty subjects aged between 50 and 70 years volunteered in this study. They were categorized into three groups which were healthy (n = 20), mild (n = 20) and moderate (n = 20) bilateral knee osteoarthritis groups. Dynamic and static balance and risk of fall were assessed using Biodex Stability System. In addition, Timed Up and Go test was used as a clinical test for balance. Results of this study illustrated that there were significant differences in balance (dynamic and static) and risk of fall between three groups. In addition, the main (most significant) difference was found to be between healthy group and moderate group. Furthermore, on clinical scoring of balance, the “Timed Up and Go” test, all three groups showed significant difference. In conclusion, bilateral knee osteoarthritis impaired the balance and increased the risk of fall, particularly in people with moderate knee osteoarthritis. PMID:24642715

  14. Balance and risk of fall in individuals with bilateral mild and moderate knee osteoarthritis.

    PubMed

    Khalaj, Nafiseh; Abu Osman, Noor Azuan; Mokhtar, Abdul Halim; Mehdikhani, Mahboobeh; Wan Abas, Wan Abu Bakar

    2014-01-01

    Balance is essential for mobility and performing activities of daily living. People with knee osteoarthritis display impairment in knee joint proprioception. Thus, the aim of this study was to evaluate balance and risk of fall in individuals with bilateral mild and moderate knee osteoarthritis. Sixty subjects aged between 50 and 70 years volunteered in this study. They were categorized into three groups which were healthy (n = 20), mild (n = 20) and moderate (n = 20) bilateral knee osteoarthritis groups. Dynamic and static balance and risk of fall were assessed using Biodex Stability System. In addition, Timed Up and Go test was used as a clinical test for balance. Results of this study illustrated that there were significant differences in balance (dynamic and static) and risk of fall between three groups. In addition, the main (most significant) difference was found to be between healthy group and moderate group. Furthermore, on clinical scoring of balance, the "Timed Up and Go" test, all three groups showed significant difference. In conclusion, bilateral knee osteoarthritis impaired the balance and increased the risk of fall, particularly in people with moderate knee osteoarthritis.

  15. Development of computer tablet software for clinical quantification of lateral knee compartment translation during the pivot shift test.

    PubMed

    Muller, Bart; Hofbauer, Marcus; Rahnemai-Azar, Amir Ata; Wolf, Megan; Araki, Daisuke; Hoshino, Yuichi; Araujo, Paulo; Debski, Richard E; Irrgang, James J; Fu, Freddie H; Musahl, Volker

    2016-01-01

    The pivot shift test is a commonly used clinical examination by orthopedic surgeons to evaluate knee function following injury. However, the test can only be graded subjectively by the examiner. Therefore, the purpose of this study is to develop software for a computer tablet to quantify anterior translation of the lateral knee compartment during the pivot shift test. Based on the simple image analysis method, software for a computer tablet was developed with the following primary design constraint - the software should be easy to use in a clinical setting and it should not slow down an outpatient visit. Translation of the lateral compartment of the intact knee was 2.0 ± 0.2 mm and for the anterior cruciate ligament-deficient knee was 8.9 ± 0.9 mm (p < 0.001). Intra-tester (ICC range = 0.913 to 0.999) and inter-tester (ICC = 0.949) reliability were excellent for the repeatability assessments. Overall, the average percent error of measuring simulated translation of the lateral knee compartment with the tablet parallel to the monitor increased from 2.8% at 50 cm distance to 7.7% at 200 cm. Deviation from the parallel position of the tablet did not have a significant effect until a tablet angle of 45°. Average percent error during anterior translation of the lateral knee compartment of 6mm was 2.2% compared to 6.2% for 2 mm of translation. The software provides reliable, objective, and quantitative data on translation of the lateral knee compartment during the pivot shift test and meets the design constraints posed by the clinical setting.

  16. Predictors of outcome after manipulation under anaesthesia in patients with a stiff total knee arthroplasty.

    PubMed

    Vanlommel, L; Luyckx, T; Vercruysse, G; Bellemans, J; Vandenneucker, H

    2017-11-01

    Flexion in a stiff total knee arthroplasty (TKA) can be improved by manipulation under anaesthesia (MUA). Although this intervention usually results in an improvement in range of motion, the expected result is not always achieved. The purpose of this study is to determine which factors affect range of motion after manipulation in patients with a stiff total knee. After exclusion (n = 22), the data of 158 patients (138 knees) with a stiff knee after TKA who received a manipulation under anaesthesia between 2004 and 2014 were retrospectively analysed. Pre-, peri- and post-operative variables were identified and examined for their influence on flexion after the manipulation using Kruskal-Wallis and Mann-Whitney U tests and Spearman correlations. After MUA, a mean improvement in flexion of 30.3° was observed at the final follow-up. Preoperative TKA flexion, design of TKA and interval between TKA procedure and MUA were positive associated with an increase in flexion after MUA. MUA performed 12 weeks or more after TKA procedure deteriorated the outcome. Three factors, pre-TKA flexion type of prosthesis and interval between TKA procedure and manipulation under anaesthesia, were found to have impact on flexion after TKA and MUA were identified. Results are expected to be inferior in patients with low flexion before TKA procedure or with a long interval (>12 weeks) between the TKA procedure and the manipulation under anaesthesia. IV.

  17. Comparison of in situ forces and knee kinematics in anteromedial and high anteromedial bundle augmentation for partially ruptured anterior cruciate ligament.

    PubMed

    Xu, Yan; Liu, Jianyu; Kramer, Scott; Martins, Cesar; Kato, Yuki; Linde-Rosen, Monica; Smolinski, Patrick; Fu, Freddie H

    2011-02-01

    High tunnel placement is common in single- and double-bundle anterior cruciate ligament (ACL) reconstructions. Similar nonanatomic tunnel placement may also occur in ACL augmentation surgery. In this study, in situ forces and knee kinematics were compared between nonanatomic high anteromedial (AM) and anatomic AM augmentation in a knee with isolated AM bundle injury. Controlled laboratory study. Seven fresh-frozen cadaver knees were used (age, 48 ± 12.5 years). First, intact knee kinematics was tested with a robotic-universal force sensor testing system under 2 loading conditions. An 89-N anterior load was applied, and an anterior tibial translation was measured at knee flexion angles of 0°, 30°, 60°, and 90°. Then, combined rotatory loads of 7-N·m valgus and 5-N·m internal tibial rotation were applied at 15° and 30° of knee flexion angles, which mimic the pivot shift. Afterward, only the AM bundle of the ACL was cut arthroscopically, keeping the posterolateral bundle intact. The knee was again tested using the intact knee kinematics to measure the in situ force of the AM bundle. Then, arthroscopic anatomic AM bundle reconstruction was performed with an allograft, and the knee was tested to give the in situ force of the reconstructed AM bundle. Knee kinematics under the 3 conditions (intact, anatomic AM augmentation, and nonanatomic high AM augmentation) and the in situ force were compared and analyzed. The high AM graft had significantly lower in situ force than the intact and anatomic reconstructed AM bundle at 0° of knee flexion (P < .05) and the intact AM bundle at 30° of knee flexion under anterior tibial loading. There were no differences between anatomic graft and intact AM bundle. The high AM graft also had a significantly lower in situ force than the intact and anatomic reconstructed AM with simulated pivot-shift loading at 15° and 30° of flexion (P < .05). Under anterior tibial and rotatory loading, there was a difference in tibial displacement between anatomic and high AM reconstructions and between the high AM graft and intact ACL under rotational loading with the knee at 15° of flexion. Anatomic AM augmentation can lead to biomechanical advantages at time zero when compared with the nonanatomic (high AM) augmentation. Anatomic AM augmentation better restores the knee kinematics to the intact ACL state.

  18. New Generation Lockable Knee Brace

    NASA Technical Reports Server (NTRS)

    1996-01-01

    A knee brace that uses Space Shuttle propulsion technology has moved a step closer to being available to help knee injury and stroke patients and may possibly benefit patients with birth defects, spinal cord injuries, and post-polio conditions. After years of hard work, inventors at NASA's Marshall Space Flight Center (MSFC) in Huntsville, Alabama, have turned over the final design and prototype to industry partners at Horton's Orthotic Lab in Little Rock, Arkansas for further clinical testing. The device, called the Selectively Lockable Knee Brace, may mean faster, less painful rehabilitation for patients by allowing the knee to move when weight is not on the heel. Devices currently on the market lock the knee in a rigid, straight-leg position, or allow continuous free motion. Pictured here is a knee brace prototype being tested and fitted at Horton's Orthotic Lab. The knee brace is just one example of how space technology is being used to improve the lives of people on Earth. NASA's MSFC inventors Michael Shadoan and Neill Myers are space propulsion engineers who use the same mechanisms and materials to build systems for rockets that they used to design and develop the knee brace.

  19. Can in vitro systems capture the characteristic differences between the flexion-extension kinematics of the healthy and TKA knee?

    PubMed

    Varadarajan, Kartik M; Harry, Rubash E; Johnson, Todd; Li, Guoan

    2009-10-01

    In vitro systems provide a powerful means to evaluate the efficacy of total knee arthroplasty (TKA) in restoring normal knee kinematics. The Oxford knee rig (OKR) and the robotic knee testing system (RKTS) represent two systems that have been extensively used to study TKA biomechanics. Nonetheless, a frequently asked question is whether in vitro simulations can capture the in vivo behavior of the knee. Here, we compared the flexion-extension kinematics of intact knees and knees after TKA tested on the OKR and RKTS, to results of representative in vivo studies. The goal was to determine if the in vitro systems could capture the key kinematic features of knees in healthy subjects and TKA patients. Results showed that the RKTS and the OKR can replicate the femoral rollback and 'screw home' tibial rotation between 0 degrees and 30 degrees flexion seen in healthy subjects, and the reduced femoral rollback and absence of 'screw home' motion in TKA patients. The RKTS also replicated the overall internally rotated position of the tibia beyond 30 degrees flexion. However, ability of the OKR to replicate the internally rotated position of the knee beyond 30 degrees flexion was inconsistent. These data could aid in validation of new in vitro systems and physiologic interpretations of in vitro results.

  20. Evaluating the suitability of highly cross-linked and remelted materials for use in posterior stabilized knees.

    PubMed

    Huot, J Caitlin; Van Citters, Douglas W; Currier, John H; Currier, Barbara H; Mayor, Michael B; Collier, John P

    2010-11-01

    Posterior stabilized (PS) knee designs are a popular choice for cruciate sacrificing knee arthroplasty procedures. The introduction of PS inserts fabricated from highly cross-linked and remelted Ultra High Molecular Weight Polyethylene (UHMWPE) has recently generated concern as these materials have been shown to possess reduced mechanical properties. This study investigated whether highly cross-linked and remelted UHMWPE material (referred to as XRP) can be expected to perform similarly to historical gamma-air polyethylene, which has suffered few reported incidences of tibial post failure. Never-implanted gamma-air PS tibial inserts shelf-aged 14 years were examined and compared to XRP materials. Evaluation of oxidation levels, impact toughness, and fatigue strength demonstrated never-implanted gamma-air PS tibial inserts to possess nonuniform mechanical properties. Despite severe oxidation along the exterior of gamma-air tibial posts, comparatively low oxidation levels at the center of the tibial posts corresponded to sufficiently high mechanical properties. XRP material (75 kGy) showed superior impact toughness over shelf aged gamma-air material; however, tibial post fatigue testing demonstrated XRP material (100 kGy) to be less resistant to fatigue failure than historical gamma-air material. Results from this study indicate that XRP materials (100 kGy) may demonstrate an inferior resistance to tibial post failure than historical polyethylene. © 2010 Wiley Periodicals, Inc.

  1. Mediolateral femoral component position in TKA significantly alters patella shift and femoral roll-back.

    PubMed

    Steinbrück, Arnd; Schröder, Christian; Woiczinski, Matthias; Schmidutz, Florian; Müller, Peter E; Jansson, Volkmar; Fottner, Andreas

    2017-11-01

    Increased retropatellar pressure and altered kinematics are associated with anterior knee pain and unsatisfied patients after total knee arthroplasty (TKA). Since malposition of the implant is believed to contribute to postoperative pain, we performed this in vitro study to evaluate the influence of mediolateral femoral component position on retropatellar pressure as well as tibio-femoral and patella kinematics. For the test, a fixed-bearing TKA was implanted in eight fresh frozen cadaver specimens. To determine the impact of mediolateral (ML) position, three variants of femoral components (3-mm medialization, neutral position and 3-mm lateralization) were produced using rapid prototyping replicas. In a knee rig, a loaded squat from 20° to 120° of flexion was applied. Retropatellar pressure distribution was measured with a pressure-sensitive film. Additionally, an ultrasonic-based three-dimensional motion analysis system was used to register patello- and tibio-femoral kinematics. ML translation of the femoral component by 3 mm did not lead to a significant alteration in retropatellar peak pressure (medial 6.5 ± 2.5 MPa vs. lateral 6.0 ± 2.4 MPa). Following the ML translation of the femoral component, the patella was significantly shifted and tilted in the same directions. Varying the ML femoral component position also led to a significant alteration in femoral roll-back. In day-by-day use, ML position should be chosen with care since there is a significant influence on patella shift and femoral roll-back. Retropatellar pressure is not significantly altered, so there is no clear evidence of an impact on anterior knee pain.

  2. Is knee function better with contemporary modular bicompartmental arthroplasty compared to total knee arthroplasty? Short-term outcomes of a prospective matched study including 68 cases.

    PubMed

    Parratte, S; Ollivier, M; Opsomer, G; Lunebourg, A; Argenson, J-N; Thienpont, E

    2015-09-01

    Bicompartmental knee arthroplasty (BKA) was developed to treat medial tibiofemoral and patellofemoral osteoarthritis while preserving the anterior cruciate ligament to optimise knee kinematics. Our objective here was to compare the probability of achieving forgotten knee status and the functional outcomes at least two years after BKA versus total knee arthroplasty (TKA). We hypothesised that contemporary modular BKA produced better functional outcomes than TKA after at least two years, for patients with similar pre-operative osteoarthritic lesions. We conducted a two-centre prospective controlled study of 34consecutive patients who underwent BKA between January 2008 and January 2011. Each patient was matched on age, gender, body mass index, preoperative range of knee flexion, centre, and surgeon to a patient treated with TKA. An independent observer evaluated all 68 patients after six and 12months then once a year. Forgotten knee status was defined as a 100/100 value of the Forgotten Joint Score (FJS-12) and each of the five KOOS subscales. We also compared the two groups for knee range of motion, Knee Society Scores (KSSs), Timed Up-and-Go test (TUG), and UCLA Activity Score. At a mean follow-up of 3.8±1.7 years, the probability of forgotten knee status was significantly higher in the BKA group (odds ratio, 4.64; 95% confidence interval, 1.63-13.21; P=0.007, Chi(2) test). Mean post-operative extension was not significantly different between the groups, whereas mean range of knee flexion was significantly greater in the BKA group (130°±6° vs. 125°±8° after TKA; P=0.03). The BKA group had significantly higher mean values for the knee and function KSSs, TUG test, and UCLA score (P<0.04 for all four comparisons). After at least two years, contemporary unlinked BKA was associated with greater comfort during everyday activities (forgotten knee) and better functional outcomes, compared to TKA. These short-term results require validation in randomised trials with longer follow-ups. III, case-control study. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  3. The use of synthetic ligaments in the design of an enhanced stability total knee joint replacement.

    PubMed

    Stokes, Michael D; Greene, Brendan C; Pietrykowski, Luke W; Gambon, Taylor M; Bales, Caroline E; DesJardins, John D

    2018-03-01

    Current total knee replacement designs work to address clinically desired knee stability and range of motion through a balance of retained anatomy and added implant geometry. However, simplified implant geometries such as bearing surfaces, posts, and cams are often used to replace complex ligamentous constraints that are sacrificed during most total knee replacement procedures. This article evaluates a novel total knee replacement design that incorporates synthetic ligaments to enhance the stability of the total knee replacement system. It was hypothesized that by incorporating artificial cruciate ligaments into a total knee replacement design at specific locations and lengths, the stability of the total knee replacement could be significantly altered while maintaining active ranges of motion. The ligament attachment mechanisms used in the design were evaluated using a tensile test, and determined to have a safety factor of three with respect to expected ligamentous loading in vivo. Following initial computational modeling of possible ligament orientations, a physical prototype was constructed to verify the function of the design by performing anterior/posterior drawer tests under physiologic load. Synthetic ligament configurations were found to increase total knee replacement stability up to 94% compared to the no-ligament case, while maintaining total knee replacement flexion range of motion between 0° and 120°, indicating that a total knee replacement that incorporates synthetic ligaments with calibrated location and lengths should be able to significantly enhance and control the kinematic performance of a total knee replacement system.

  4. The saline load test of the knee redefined: a test to detect traumatic arthrotomies and rule out periarticular wounds not requiring surgical intervention.

    PubMed

    Konda, Sanjit R; Howard, Daniel; Davidovitch, Roy I; Egol, Kenneth A

    2013-09-01

    To describe the use of the saline load test (SLT) using a new definition that more adequately characterizes its use in the emergency department (ED) setting. Retrospective review. Level I trauma center. Fifty consecutive patients who underwent an SLT of the knee in the ED and had a minimum of 14 days follow-up. Saline Load Test. Positive traumatic arthrotomy of the knee (+TAK) defined as operating room (OR) confirmation of an arthrotomy (assumed to develop a septic knee) or -SLT with follow-up revealing a septic knee. Periarticular wound equivalent to no traumatic arthrotomy of the knee [pw = (-TAK)] defined as OR evaluation revealing no arthrotomy (assumed not to develop a septic knee) or -SLT whose follow-up revealed no septic knee. Development of a septic knee was considered the gold standard for determining true positives/negatives and false positives/negatives. The mean wound size was 3.9 ± 4.3 cm and the mean saline load volume was 74.9 ± 28.2 cm. There were 19 +SLTs of which there were 16 +TAK and 3 pw = (-TAK). The 3 pw = (-TAK) in the +SLT group were evaluated in the OR where inspection of the joint capsule revealed the absence of a traumatic arthrotomy. There were 31 -SLTs of which there were 1 +TAK and 30 pw = (-TAK). The SLT has a sensitivity of 94% and a specificity of 91% for detecting +TAKs and ruling out periarticular wounds not requiring surgical intervention [pw = (-TAK)]. The false-positive rate of the SLT to detect +TAK is 9%. Using +TAK and pw = (-TAK) as the newly defined measures of the SLT, we report the sensitivity (94%) and specificity (91%) of the SLT in the ED setting while still maintaining the clinical relevancy of the test. Based on a small sample size, knees with small periarticular wounds and a -SLT and no other radiographic or clinical evidence of an arthrotomy appear to have an infection rate of 0% with nonoperative management. Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  5. Soldier-relevant body borne loads increase knee joint contact force during a run-to-stop maneuver.

    PubMed

    Ramsay, John W; Hancock, Clifford L; O'Donovan, Meghan P; Brown, Tyler N

    2016-12-08

    The purpose of this study was to understand the effects of load carriage on human performance, specifically during a run-to-stop (RTS) task. Using OpenSim analysis tools, knee joint contact force, grounds reaction force, leg stiffness and lower extremity joint angles and moments were determined for nine male military personnel performing a RTS under three load configurations (light, ~6kg, medium, ~20kg, and heavy, ~40kg). Subject-based means for each biomechanical variable were submitted to repeated measures ANOVA to test the effects of load. During the RTS, body borne load significantly increased peak knee joint contact force by 1.2 BW (p<0.001) and peak vertical (p<0.001) and anterior-posterior (p=0.002) ground reaction forces by 0.6 BW and 0.3 BW, respectively. Body borne load also had a significant effect on hip (p=0.026) posture with the medium load and knee (p=0.046) posture with the heavy load. With the heavy load, participants exhibited a substantial, albeit non-significant increase in leg stiffness (p=0.073 and d=0.615). Increases in joint contact force exhibited during the RTS were primarily due to greater GRFs that impact the soldier with each incremental addition of body borne load. The stiff leg, extended knee and large braking force the soldiers exhibited with the heavy load suggests their injury risk may be greatest with that specific load configuration. Further work is needed to determine if the biomechanical profile exhibited with the heavy load configuration translates to unsafe shear forces at the knee joint and consequently, a higher likelihood of injury. Published by Elsevier Ltd.

  6. Computed tomography scan to detect traumatic arthrotomies and identify periarticular wounds not requiring surgical intervention: an improvement over the saline load test.

    PubMed

    Konda, Sanjit R; Davidovitch, Roy I; Egol, Kenneth A

    2013-09-01

    To report our experience with computed tomography (CT) scans to detect traumatic arthrotomies of the knee (TAK) joint based on the presence of intra-articular air. Retrospective review. Level I trauma center. Sixty-two consecutive patients (63 knees) underwent a CT scan of the knee in the emergency department and had a minimum of 14 days follow-up. Cohort of 37 patients (37 knees) from the original 62 patients who underwent a saline load test (SLT). CT scan and SLT. Positive traumatic arthrotomy of the knee (+TAK) was defined as operating room (OR) confirmation of an arthrotomy or no intra-articular air on CT scan (-iaCT) (and -SLT if performed) with follow-up revealing a septic knee. Periarticular wound equivalent to no traumatic arthrotomy (pw = (-TAK)) was defined as OR evaluation revealing no arthrotomy or -iaCT (and -SLT if performed) with follow-up revealing no septic knee. All 32 knees with intra-articular air on CT scan (+iaCT) had OR confirmation of a TAK and none of these patients had a knee infection at a mean follow-up of 140.0 ± 279.6 days. None of the 31 patients with -iaCT had a knee infection at a mean follow-up of 291.0 ± 548.1 days. Based on these results, the sensitivity and specificity of the CT scan to detect +TAK and pw = (-TAK) was 100%. In a subgroup of 37 patients that received both a CT scan and the conventional SLT, the sensitivity and specificity of the CT scan was 100% compared with 92% for the SLT (P < 0.001). CT scan performs better than the conventional SLT to detect traumatic knee arthrotomies and identify periarticular knee wounds that do not require surgical intervention and should be considered a valid diagnostic test in the appropriate clinical setting. Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  7. A comparison of two stretching programs for hamstring muscles: A randomized controlled assessor-blinded study.

    PubMed

    Demoulin, Christophe; Wolfs, Sébastien; Chevalier, Madeline; Granado, Caroline; Grosdent, Stéphanie; Depas, Yannick; Roussel, Nathalie; Hage, Renaud; Vanderthommen, Marc

    2016-01-01

    Most parameters regarding hamstring flexibility training programs have been investigated; however, the joint (i.e. hip or knee) on which the stretching should preferentially be focused needs to be further explored. This randomized controlled assessor-blinded study aimed to investigate the influence of this parameter. We randomly assigned 111 asymptomatic participants with tight hamstring muscles in three groups: a control group and two groups following a different home-based 8-week (five 10-minute sessions per week) hamstring stretching program (i.e. stretching performed by flexing the hip while keeping the knee extended [SH] or by first flexing the hip with a flexed knee and then extending the knee [SK]). Range of motion (ROM) of hip flexion and knee extension were measured before and after the stretching program by means of the straight leg raising test and the passive knee extension angle test, respectively. Eighty-nine participants completed the study. A significant increase in ROM was observed at post-test. Analyses showed significant group-by-time interactions for changes regarding all outcomes. Whereas the increase in hip flexion and knee extension ROM was higher in the stretching groups than in the CG (especially for the SH group p < 0.05), no differences between the two stretching groups were observed (p > 0.05). In conclusion, the fact that both stretching programs resulted in similar results suggests no influence of the joint at which the stretching is focused upon, as assessed by the straight leg raising and knee extension angle tests.

  8. The effect of knee extensor open kinetic chain resistance training in the ACL-injured knee.

    PubMed

    Barcellona, Massimo G; Morrissey, Matthew C; Milligan, Peter; Clinton, Melissa; Amis, Andrew A

    2015-11-01

    To investigate the effect of different loads of knee extensor open kinetic chain resistance training on anterior knee laxity and function in the ACL-injured (ACLI) knee. Fifty-eight ACLI subjects were randomised to one of three (12-week duration) training groups. The STAND group trained according to a standardised rehabilitation protocol. Subjects in the LOW and HIGH group trained as did the STAND group but with the addition of seated knee extensor open kinetic chain resistance training at loads of 2 sets of 20 repetition maximum (RM) and 20 sets of 2RM, respectively. Anterior knee laxity and measurements of physical and subjective function were performed at baseline, 6 and 12 weeks. Thirty-six subjects were tested at both baseline and 12 weeks (STAND n = 13, LOW n = 11, HIGH n = 12). The LOW group demonstrated a reduction in 133 N anterior knee laxity between baseline and 12 weeks testing when compared to the HIGH and the STAND groups (p = 0.009). Specifically, the trained-untrained knee laxity decreased an average of approximately 5 mm in the LOW group while remaining the same in the other two groups. Twelve weeks of knee extensor open kinetic chain resistance training at loads of 2 sets of 20RM led to a reduction in anterior knee laxity in the ACLI knee. This reduction in laxity does not appear to offer any significant short-term functional advantages when compared to a standard rehabilitation protocol. These results indicate that knee laxity can be decreased with resistance training of the thigh muscles. Randomised controlled trial, Level II.

  9. Effectiveness of the Saline Load Test in Diagnosis of Traumatic Elbow Arthrotomies

    DTIC Science & Technology

    2011-11-01

    load test for the knee, using 80 knees in patients undergoing elective knee arthroscopy . A fixed volume of 60 mL of saline was injected while observing... Arthroscopy . 1990;6:100–103. 10. Voit GA, Irvine G, Beals RK. Saline load test for penetration of periarticular lacerations. J Bone Joint Surg Br. 1996;78:732...318. 12. Plancher KD, Shariff KB. Basics of elbow arthroscopy : setup, portals, and technique. Tech Orthop. 2006;21:239–249. 13. Marvel JE, Marsh HO

  10. A statistically compiled test battery for feasible evaluation of knee function after rupture of the Anterior Cruciate Ligament – derived from long-term follow-up data

    PubMed Central

    2017-01-01

    Purpose Clinical test batteries for evaluation of knee function after injury to the Anterior Cruciate Ligament (ACL) should be valid and feasible, while reliably capturing the outcome of rehabilitation. There is currently a lack of consensus as to which of the many available assessment tools for knee function that should be included. The present aim was to use a statistical approach to investigate the contribution of frequently used tests to avoid redundancy, and filter them down to a proposed comprehensive and yet feasible test battery for long-term evaluation after ACL injury. Methods In total 48 outcome variables related to knee function, all potentially relevant for a long-term follow-up, were included from a cross-sectional study where 70 ACL-injured (17–28 years post injury) individuals were compared to 33 controls. Cluster analysis and logistic regression were used to group variables and identify an optimal test battery, from which a summarized estimator of knee function representing various functional aspects was derived. Results As expected, several variables were strongly correlated, and the variables also fell into logical clusters with higher within-correlation (max ρ = 0.61) than between clusters (max ρ = 0.19). An extracted test battery with just four variables assessing one-leg balance, isokinetic knee extension strength and hop performance (one-leg hop, side hop) were mathematically combined to an estimator of knee function, which acceptably classified ACL-injured individuals and controls. This estimator, derived from objective measures, correlated significantly with self-reported function, e.g. Lysholm score (ρ = 0.66; p<0.001). Conclusions The proposed test battery, based on a solid statistical approach, includes assessments which are all clinically feasible, while also covering complementary aspects of knee function. Similar test batteries could be determined for earlier phases of ACL rehabilitation or to enable longitudinal monitoring. Such developments, established on a well-grounded consensus of measurements, would facilitate comparisons of studies and enable evidence-based rehabilitation. PMID:28459885

  11. The Role of Neuromuscular Changes in Aging and Knee Osteoarthritis on Dynamic Postural Control

    PubMed Central

    Takacs, Judit; Carpenter, Mark G.; Garland, S. Jayne; Hunt, Michael A.

    2013-01-01

    Knee osteoarthritis (OA) is a chronic joint condition, with 30% of those over the age of 75 exhibiting severe radiographic disease. Nearly 50% of those with knee OA have experienced a fall in the past year. Falls are a considerable public health concern, with a high risk of serious injury and a significant socioeconomic impact. The ability to defend against a fall relies on adequate dynamic postural control, and alterations in dynamic postural control are seen with normal aging. Neuromuscular changes associated with aging may be responsible for some of these alterations in dynamic postural control. Even greater neuromuscular deficits, which may impact dynamic postural control and the ability to defend against a fall, are seen in people with knee OA. There is little evidence to date on how knee OA affects the ability to respond to and defend against falls and the neuromuscular changes that contribute to balance deficits. As a result, this review will: summarize the key characteristics of postural responses to an external perturbation, highlight the changes in dynamic postural control seen with normal aging, review the neuromuscular changes associated with aging that have known and possible effects on dynamic postural control, and summarize the neuromuscular changes and balance problems in knee OA. Future research to better understand the role of neuromuscular changes in knee OA and their effect on dynamic postural control will be suggested. Such an understanding is critical to the successful creation and implementation of fall prevention and treatment programs, in order to reduce the excessive risk of falling in knee OA. PMID:23696951

  12. Polyethylene damage and deformation on fixed-bearing, non-conforming unicondylar knee replacements corresponding to progressive changes in alignment and fixation.

    PubMed

    Harman, Melinda K; Schmitt, Sabine; Rössing, Sven; Banks, Scott A; Sharf, Hans-Peter; Viceconti, Marco; Hodge, W Andrew

    2010-07-01

    Deviations from nominal alignment of unicondylar knee replacements impact knee biomechanics, including the load and stress distribution at the articular contact surfaces. This study characterizes relationships between the biomechanical environment, distinguished by progressive changes in alignment and fixation, and articular damage and deformation in a consecutive series of retrieved unicondylar knee replacements. Twenty seven fixed-bearing, non-conforming unicondylar knee replacements of one design were retrieved after 2 to 13 years of in vivo function. The in vivo biomechanical environment was characterized by grading component migration measured from full-length radiographs and grading component fixation based on intraoperative manual palpation. Articular damage patterns and linear deformation on the polyethylene inserts were measured using optical photogrammetry and contact point digitization. Articular damage patterns and surface deformation on the explanted polyethylene inserts corresponded to progressive changes in component alignment and fixation. Component migration produced higher deformation rates, whereas loosening contributed to larger damage areas but lower deformation rates. Migration and loosening of the femoral component, but not the tibial component, were factors contributing to large regions of abrasion concentrated on the articular periphery. Classifying component migration and fixation at revision proved useful for distinguishing common biomechanical conditions associated with the varied polyethylene damage patterns and linear deformation for this fixed-bearing, non-conforming design. Pre-clinical evaluations of unicondylar knee replacements that are capable of reproducing variations in clinical alignment and predicting the observed wear mechanisms are necessary to better understand the impact of knee biomechanics and design on unicondylar knee replacement longevity. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  13. The effect of proximal tibial slope on dynamic stability testing of the posterior cruciate ligament- and posterolateral corner-deficient knee.

    PubMed

    Petrigliano, Frank A; Suero, Eduardo M; Voos, James E; Pearle, Andrew D; Allen, Answorth A

    2012-06-01

    Proximal tibial slope has been shown to influence anteroposterior translation and tibial resting point in the posterior cruciate ligament (PCL)-deficient knee. The effect of proximal tibial slope on rotational stability of the knee is unknown. Change in proximal tibial slope produced via osteotomy can influence both static translation and dynamic rotational kinematics in the PCL/posterolateral corner (PLC)-deficient knee. Controlled laboratory study. Posterior drawer, dial, and mechanized reverse pivot-shift (RPS) tests were performed on hip-to-toe specimens and translation of the lateral and medial compartments measured utilizing navigation (n = 10). The PCL and structures of the PLC were then sectioned. Stability testing was repeated, and compartmental translation was recorded. A proximal tibial osteotomy in the sagittal plane was then performed achieving either +5° or -5° of tibial slope variation, after which stability testing was repeated (n = 10). Analysis was performed using 1-way analysis of variance (ANOVA; α = .05). Combined sectioning of the PCL and PLC structures resulted in a 10.5-mm increase in the posterior drawer, 15.5-mm increase in the dial test at 30°, 14.5-mm increase in the dial test at 90°, and 17.9-mm increase in the RPS (vs intact; P < .05). Increasing the posterior slope (high tibial osteotomy [HTO] +5°) in the PCL/PLC-deficient knee reduced medial compartment translation by 3.3 mm during posterior drawer (vs deficient; P < .05) but had no significant effect on the dial test at 30°, dial test at 90°, or RPS. Conversely, reversing the slope (HTO -5°) caused a 4.8-mm increase in medial compartment translation (vs deficient state; P < .05) during posterior drawer and an 8.6-mm increase in lateral compartment translation and 9.0-mm increase in medial compartment translation during RPS (vs deficient state; P < .05). Increasing posterior tibial slope diminished static posterior instability of the PCL/PLC-deficient knee as measured by the posterior drawer test but had little effect on rotational or dynamic multiplanar stability as assessed by the dial and RPS tests, respectively. Conversely, decreasing posterior slope resulted in increased posterior instability and a significant increase in the magnitude of the RPS. These results suggest that increasing posterior tibial slope may improve sagittal stability in the PCL/PLC-deficient knee. Moreover, a knee with diminished posterior tibial slope may demonstrate greater multiplanar instability in this setting. Consequently, proximal tibial slope should be considered when treating combined PCL/PLC injuries of the knee.

  14. The Association Between Visual Assessment of Quality of Movement and Three-Dimensional Analysis of Pelvis, Hip, and Knee Kinematics During a Lateral Step Down Test.

    PubMed

    Rabin, Alon; Portnoy, Sigal; Kozol, Zvi

    2016-11-01

    Rabin, A, Portnoy, S, and Kozol, Z. The association between visual assessment of quality of movement and three-dimensional analysis of pelvis, hip, and knee kinematics during a lateral step down test. J Strength Cond Res 30(11): 3204-3211, 2016-Altered movement patterns including contralateral pelvic drop, increased hip adduction, knee abduction, and external rotation have been previously implicated in several lower extremity pathologies. Although various methods exist for assessing movement patterns, real-time visual observation is the most readily available method. The purpose of this study was to determine whether differing visual ratings of trunk, pelvis, and knee alignment, as well as overall quality of movement, are associated with differences in 3-dimensional trunk, pelvis, hip, or knee kinematics during a lateral step down test. Trunk, pelvis, and knee alignment of 30 healthy participants performing the lateral step down were visually rated as "good" or "faulty" based on previously established criteria. An additional categorization of overall quality of movement as either good or moderate was performed based on the aggregate score of each individual rating criterion. Three-dimensional motion analysis of trunk, pelvis, hip, and knee kinematics was simultaneously performed. A faulty pelvis alignment displayed a greater peak contralateral pelvic drop (effect size [ES], 1.65; p < 0.01) and a greater peak hip adduction (ES: 1.04, p = 0.01) compared with participants with a good pelvis alignment. Participants with a faulty knee alignment displayed greater peak knee external rotation compared with participants with a good knee alignment (ES, 0.78; p = 0.02). Participants with an overall moderate quality of movement displayed increased peak contralateral pelvic drop (ES, 1.07; p = 0.01) and peak knee external rotation (ES, 0.72; p = 0.04) compared with those with an overall good quality of movement. Visual rating of quality of movement during a lateral step down test, as performed by an experienced physical therapist, is associated with differences in several kinematics previously implicated in various pathologies.

  15. Intra-limb coordination in karate kicking: Effect of impacting or not impacting a target.

    PubMed

    Quinzi, Federico; Sbriccoli, Paola; Alderson, Jacqueline; Di Mario, Alberto; Camomilla, Valentina

    2014-02-01

    This study aimed to investigate the kicking limb coordinative patterns adopted by karate practitioners (karateka) when impacting (IRK), or not impacting (NIRK) a target during a roundhouse kick. Six karateka performed three repetitions of both kicks while kicking limb kinematics were recorded using a stereophotogrammetric system. Intra-limb coordination was quantified for hip and knee flexion-extension from toe-off to kick completion, using the Continuous relative phase (CRP). Across the same time interval, thigh and shank angular momentum about the vertical axis of the body was calculated. For all trials, across all participants, CRP curve peaks and maximum and minimum angular momentum were determined. A RM-ANOVA was performed to test for differences between kicking conditions. The CRP analysis highlighted, during the central portion of both kicks, a delayed flexion of the hip with respect to the knee. Conversely, during the terminal portion of the CRP curves, the NIRK is performed with a more in-phase action, caused by a higher hip angular displacement. The NIRK is characterized by a lower angular momentum which may enhance control of the striking limb. It would seem that the issue of no impact appears to be solved through the control of all segments of the kicking limb, in contrast to the primary control of the lower leg only observed during the IRK. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Physical Examination of the Knee: Meniscus, Cartilage, and Patellofemoral Conditions.

    PubMed

    Bronstein, Robert D; Schaffer, Joseph C

    2017-05-01

    The knee is one of the most commonly injured joints in the body. Its superficial anatomy enables diagnosis of the injury through a thorough history and physical examination. Examination techniques for the knee described decades ago are still useful, as are more recently developed tests. Proper use of these techniques requires understanding of the anatomy and biomechanical principles of the knee as well as the pathophysiology of the injuries, including tears to the menisci and extensor mechanism, patellofemoral conditions, and osteochondritis dissecans. Nevertheless, the clinical validity and accuracy of the diagnostic tests vary. Advanced imaging studies may be useful adjuncts.

  17. Reliability of a device for the knee and ankle isometric and isokinetic strength testing in older adults

    PubMed Central

    Bergamin, Marco; Gobbo, Stefano; Bullo, Valentina; Vendramin, Barbara; Duregon, Federica; Frizziero, Antonio; Di Blasio, Andrea; Cugusi, Lucia; Zaccaria, Marco; Ermolao, Andrea

    2017-01-01

    Summary Background Lower extremity muscle mass, strength, power, and physical performance are critical determinants of independent functioning in later life. Isokinetic dynamometers are becoming very common in assessing different features of muscle strength, in both research and clinical practice; however, reliability studies are still needed to support the extended use of those devices. Objective The purpose of this study is to assess the test-retest reliability of knee and ankle isokinetic and isometric strength testing protocols in a sample of older healthy subjects, using a new and untested isokinetic multi-joint evaluation system. Methods Sixteen male and fourteen female older adults (mean age 65.2 ± 4.6 years) were assessed in two testing sessions. Each participant performed a randomized testing procedure that includes different isometric and isokinetic tests for knee and ankle joints. Results All participants concluded the trial safety and no subject reported any discomfort throughout the overall assessment. Coefficients of correlation between measures were calculated showing moderate to strong effects among all test-retest assessments and paired-sample t test showed only one significant difference (p<0.05) in the maximal isokinetic bilateral knee flexion torque. Conclusions The multi-joint evaluation system for the assessment of knee and ankle isokinetic and isometric strength provided reliable test-retest measures in healthy older adults. Level of evidence Ib. PMID:29264344

  18. Functional outcomes of outpatient balance training following total knee replacement in patients with knee osteoarthritis: a randomized controlled trial.

    PubMed

    Liao, Chun-De; Lin, Li-Fong; Huang, Yi-Ching; Huang, Shih-Wei; Chou, Lin-Chuan; Liou, Tsan-Hon

    2015-09-01

    To evaluate whether balance training after total knee replacement surgery improves functional outcomes and to determine whether postoperative balance is associated with mobility. A prospective intervention study and randomized controlled trial with an intention-to-treat analysis. The rehabilitation center of a university-based teaching hospital. A total of 130 patients with knee osteoarthritis who had undergone total knee replacement surgery were recruited to attend an outpatient rehabilitation program. They were randomly allocated to additional balance rehabilitation and functional rehabilitation groups. During the eight-week outpatient rehabilitation program, both groups received general functional training. Patients in the balance rehabilitation group received an additional balance-based rehabilitation program. The functional reach test, single-leg stance test, 10-m walk test, Timed Up and Go Test, timed chair-stand test, stair-climb test, and Western Ontario and McMaster Universities Osteoarthritis Index were measured at baseline, eight weeks (T(1)), and 32 weeks (T(2)). The balance rehabilitation group patients demonstrated significant improvement in the results of the functional reach test at T(1) (37.6 ±7.8 cm) and T(2) (39.3 ±9.7 cm) compared with the baseline assessment (11.5 ±2.9 cm) and Timed Up and Go Test at T(1) (8.9 ±1.2 seconds) and T(2) (8.0 ±1.9 seconds) compared with the baseline assessment (12.5 ±1.8 seconds). Moreover, the balance rehabilitation group patients exhibited significantly greater improvements in balance and mobility than did the functional rehabilitation group patients (all P < 0.001). Furthermore, improved balance was significantly associated with improved mobility at T(2). Postoperative outpatient rehabilitation with balance training improves the balance, mobility, and functional outcomes in patients with knee osteoarthritis after total knee replacement. © The Author(s) 2014.

  19. Hip Abductor Strengthening Improves Physical Function Following Total Knee Replacement: One-Year Follow-Up of a Randomized Pilot Study.

    PubMed

    Harikesavan, Karvannan; Chakravarty, Raj D; Maiya, Arun G; Hegde, Sanjay P; Y Shivanna, Shivakumar

    2017-01-01

    Total knee replacement (TKR) is the commonest surgical procedure for patients with severe pain and impaired physical function following end stage knee osteoarthritis. The hip abductors are well renowned in stabilization of the trunk and hip during walking, maintaining the lower limb position, and transferring the forces from the lower limbs to the pelvis. To assess the efficacy of hip abductor strengthening exercise on functional outcome using performance based outcome measures following total knee replacement. An observer blinded randomized pilot trial design was conducted at Manipal hospital, Bangalore, India. Participants designated for elective TKR were randomized to experimental group hip abductor strengthening along with standard rehabilitation (n=10) or control group standard rehabilitation alone (n=10). Participants followed for one year to assess physical function using performance based outcomes, such as timed up and go test, single leg stance test, six minute walk test, knee extensor strength and hip abductor strength. Eighteen participants with a mean age of 63.1 ± 5.5 years (8 Males and 10 Females) completed the study. Improvement in hip abduction strength, single leg stand test was superior in hip abductor strengthening group at 3 months and 1 year when compared to standard rehabilitation alone. Hip abductor strengthening showed superior improvements in single leg stance test and six minute walk test. Hip abductor strengthening exercises has the potential to improve physical function following total knee replacement.

  20. Hip Abductor Strengthening Improves Physical Function Following Total Knee Replacement: One-Year Follow-Up of a Randomized Pilot Study

    PubMed Central

    Harikesavan, Karvannan; Chakravarty, Raj D.; Maiya, Arun G; Hegde, Sanjay P.; Y. Shivanna, Shivakumar

    2017-01-01

    Background: Total knee replacement (TKR) is the commonest surgical procedure for patients with severe pain and impaired physical function following end stage knee osteoarthritis. The hip abductors are well renowned in stabilization of the trunk and hip during walking, maintaining the lower limb position, and transferring the forces from the lower limbs to the pelvis. Objective: To assess the efficacy of hip abductor strengthening exercise on functional outcome using performance based outcome measures following total knee replacement. Methods: An observer blinded randomized pilot trial design was conducted at Manipal hospital, Bangalore, India. Participants designated for elective TKR were randomized to experimental group hip abductor strengthening along with standard rehabilitation (n=10) or control group standard rehabilitation alone (n=10). Participants followed for one year to assess physical function using performance based outcomes, such as timed up and go test, single leg stance test, six minute walk test, knee extensor strength and hip abductor strength. Result: Eighteen participants with a mean age of 63.1 ± 5.5 years (8 Males and 10 Females) completed the study. Improvement in hip abduction strength, single leg stand test was superior in hip abductor strengthening group at 3 months and 1 year when compared to standard rehabilitation alone. Conclusion: Hip abductor strengthening showed superior improvements in single leg stance test and six minute walk test. Hip abductor strengthening exercises has the potential to improve physical function following total knee replacement. PMID:28567148

  1. Using a surrogate contact pair to evaluate polyethylene wear in prosthetic knee joints.

    PubMed

    Sanders, Anthony P; Lockard, Carly A; Weisenburger, Joel N; Haider, Hani; Raeymaekers, Bart

    2016-01-01

    With recent improvements to the properties of ultra-high molecular weight polyethylene (UHMWPE) used in joint replacements, prosthetic knee and hip longevity may extend beyond two decades. However, it is difficult and costly to replicate such a long in vivo lifetime using clinically relevant in vitro wear testing approaches such as walking gait joint simulators. We advance a wear test intermediate in complexity between pin-on-disk and knee joint simulator tests. The test uses a surrogate contact pair, consisting of a surrogate femoral and tibial specimen that replicate the contact mechanics of any full-scale knee condyle contact pair. The method is implemented in a standard multi-directional pin-on-disk wear test machine, and we demonstrate its application via a two-million-cycle wear test of three different UHMWPE formulations. Further, we demonstrate the use of digital photography and image processing to accurately quantify fatigue damage based on the reduced transmission of light through a damage area in a UHMWPE specimen. The surrogate contact pairs replicate the knee condyle contact areas within -3% to +12%. The gravimetric wear test results reflect the dose of crosslinking radiation applied to the UHMWPE: 35 kGy yielded a wear rate of 7.4 mg/Mcycles, 55 kGy yielded 1.0 mg/Mcycles, and 75 kGy (applied to a 0.1% vitamin E stabilized UHMWPE) yielded 1.5 mg/Mcycles. A precursor to spalling fatigue is observed and precisely measured in the radiation-sterilized (35 kGy) and aged UHMWPE specimen. The presented techniques can be used to evaluate the high-cycle fatigue performance of arbitrary knee condyle contact pairs under design-specific contact stresses, using existing wear test machines. This makes the techniques more economical and well-suited to standardized comparative testing. © 2015 Wiley Periodicals, Inc.

  2. Multidisciplinary design optimization of vehicle instrument panel based on multi-objective genetic algorithm

    NASA Astrophysics Data System (ADS)

    Wang, Ping; Wu, Guangqiang

    2013-03-01

    Typical multidisciplinary design optimization(MDO) has gradually been proposed to balance performances of lightweight, noise, vibration and harshness(NVH) and safety for instrument panel(IP) structure in the automotive development. Nevertheless, plastic constitutive relation of Polypropylene(PP) under different strain rates, has not been taken into consideration in current reliability-based and collaborative IP MDO design. In this paper, based on tensile test under different strain rates, the constitutive relation of Polypropylene material is studied. Impact simulation tests for head and knee bolster are carried out to meet the regulation of FMVSS 201 and FMVSS 208, respectively. NVH analysis is performed to obtain mainly the natural frequencies and corresponding mode shapes, while the crashworthiness analysis is employed to examine the crash behavior of IP structure. With the consideration of lightweight, NVH, head and knee bolster impact performance, design of experiment(DOE), response surface model(RSM), and collaborative optimization(CO) are applied to realize the determined and reliability-based optimizations, respectively. Furthermore, based on multi-objective genetic algorithm(MOGA), the optimal Pareto sets are completed to solve the multi-objective optimization(MOO) problem. The proposed research ensures the smoothness of Pareto set, enhances the ability of engineers to make a comprehensive decision about multi-objectives and choose the optimal design, and improves the quality and efficiency of MDO.

  3. Effects of Novel Guidance Tubing Gait on Electromyographic Neuromuscular Imbalance and Joint Angular Kinematics During Locomotion in Hemiparetic Stroke Patients.

    PubMed

    Lee, Jeong J; You, Joshua Sung H

    2017-12-01

    To compare the immediate effects of conventional treadmill gait and guidance tubing gait (GTG) on electromyographic neuromuscular imbalance and knee joint kinematics in hemiparetic gait. Case-control study. University medical center. Participants (N=33; 19 men, 14 women) were patients with hemiparetic stroke (n=18 [experimental]; mean age ± SD, 39.2±16.8y) and healthy controls (n=15; mean age ± SD, 26.3±2.6y). The GTG was provided for approximately 30 minutes and involved application of an assistive guidance force using the tubing, specifically to improve knee joint stabilization during midstance and increase knee joint flexion during midswing phase. Clinical tests included the Korean Mini-Mental State Examination, Modified Ashworth Scale, Berg Balance Scale, manual muscle test, and knee joint range of motion and sensory tests. Knee joint muscle electromyographic and kinematic analyses were determined at pretest and posttest. After the intervention, the experimental group showed significantly greater improvements in balanced quadriceps and hamstring electromyographic coactivation and knee joint kinematics relative to the control group (P=.005). The GTG intervention decreased overactive hamstring activity (P=.018) and reciprocally increased quadriceps activity (P<.001). The knee joint kinematic analysis showed significant changes in the hemiparetic stroke group (P=.004). This study demonstrates the effectiveness of the tubing gait condition to restore knee joint muscle imbalance and kinematics in individuals with hemiparetic stroke who present with an abnormal hyperextension knee gait. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  4. Cross-cultural adaptation and validation of the Arabic version of the knee outcome survey-activities for daily living scale.

    PubMed

    Bouzubar, Fawzi F; Aljadi, Sameera H; Alotaibi, Naser M; Irrgang, James J

    2018-07-01

    The purpose of this study is to cross-culturally adapt the Knee Outcome Survey-Activities of Daily Living Scale into Arabic and to assess its psychometric properties (internal consistency, reliability, validity, and responsiveness) in patients with knee disorders. The cross-cultural adaptation process for the Knee Outcome Survey-Activities of Daily Living Scale into Arabic was performed consistent with the published guidelines. The psychometric properties of this Arabic version were then evaluated. Participants completed this version three times: at baseline, 2-4 days later, and 4 weeks later. Correlations between the Arabic version of Knee Outcome Survey-Activities of Daily Living Scale and the Arabic version of the Short Form-36 Health Survey, Get Up and Go, and Ascending/Descending stairs tests were evaluated. Linguistic and cultural issues were addressed. The Arabic version of the Knee Outcome Survey-Activities of Daily Living Scale demonstrated excellent internal consistency (Cronbach's alpha = 0.97) and excellent test-retest reliability (intraclass correlation coefficient = 0.97). Construct validity of the Arabic version of the Knee Outcome Survey-Activities of Daily Living Scale with the Arabic version of Short Form-36 Health Survey subscales ranged from r = 0.28 to 0.53, p < 0.001. Criterion validity with the Get Up and Go and Ascending/Descending stairs tests ranged from r = -0.47 to -0.60, p < 0.01. This Arabic version was able to detect changes 4 weeks later (effect size = 1.12 and minimum clinically important difference = 14 points). The Arabic version of the Knee Outcome Survey-Activities of Daily Living Scale is a reliable, valid and responsive measure for assessing knee-related symptoms and functional limitations Implications for rehabilitation The Knee Outcome Survey-Activities of Daily Living Scale-Arabic is a reliable, valid and responsive measure for assessing knee-related functional limitations. This Arabic version can be used in clinical practice and for research purposes to assess symptoms and functional limitations in Arabic-speaking patients with knee disorders. This scale is responsive to track therapeutic outcome of Arabic-speaking patients with knee disorders.

  5. Self-reported Knee Function Can Identify Athletes Who Fail Return to Activity Criteria up to 1 Year after Anterior Cruciate Ligament Reconstruction. A Delaware-Oslo ACL Cohort Study

    PubMed Central

    Logerstedt, David; Stasi, Stephanie Di; Grindem, Hege; Lynch, Andrew; Eitzen, Ingrid; Engebretsen, Lars; Risberg, May Arna; Axe, Michael J; Snyder-Mackler, Lynn

    2014-01-01

    STUDY DESIGN Cohort study, cross-sectional. OBJECTIVES To determine if self-reported knee function assessed with the International Knee Documentation Committee 2000 Subjective Knee Form (IKDC2000) could discriminate between successful and non-successful performance on return to activity criteria (RTAC) tests after anterior cruciate ligament (ACL) reconstruction. BACKGROUND Rehabilitation specialists are challenged in selecting appropriate performance-based and patient-reported tests that can detect side-to-side asymmetries, assess global knee function, and determine a participant's readiness to return to activity after ACL reconstruction. A simple tool or questionnaire that could identify athletes with neuromuscular impairments or activity limitations could provide rehabilitation specialists crucial data pertinent to their current knee function and their readiness to return to higher level activities. METHODS One hundred fifty-eight Level I/II athletes 6 months after ACL reconstruction and 141 athletes 12 months after ACL reconstruction completed a functional test battery to determine readiness to return to activity and the IKDC2000 to determine self-reported knee function. For each athlete, status on return to activity tests criteria was dichotomized as “Passed” or ”Failed” and status on the IKDC2000 scores was dichotomized as being “within” or “below age- and sex-matched normal ranges”. Comparisons were made between status on RTAC and IKDC2000 using Chi-square tests. Accuracy statistics were also calculated. RESULTS Six months after ACL reconstruction, 112 athletes (70.9%) failed RTAC and 76 (48.1%) were classified as having self-reported knee function below normal ranges. Among the 76 participants with IKDC2000 scores below normal ranges, 69 (90.8%) failed RTAC test battery (P<.001). However, among the 82 participants whose IKDC2000 scores were within normal limits at 6 months, only 39 (47.6%) passed RTAC test battery (P=.74). Twelve months after ACL reconstruction, 67 athletes (47.5%) failed RTAC and 31 (78.0%) had knee function below normal ranges. Among the 31 participants with IKDC2000 scores below normal ranges, 25 (80.6%) failed RTAC test battery (P<.001). However, among the 110 participants whose IKDC2000 scores were within normal limits at 12 months, only 68 (61.8%) passed RTAC test battery (P=.017). CONCLUSION The IKDC2000 may be a clinically relevant tool to determine the timeliness or necessity of RTAC testing. For scores obtained 6 and 12 months after ACL reconstruction, low IKDC2000 scores were reasonably indicative of failure on RTAC test battery, whereas normal IKDC2000 scores were not predictive of passing scores on the RTAC test battery. PMID:25347228

  6. The older worker with osteoarthritis of the knee.

    PubMed

    Palmer, Keith T

    2012-06-01

    Changing demographics mean that many patients with large joint arthritis will work beyond traditional retirement age. This review considers the impact of knee osteoarthritis (OA) on work participation and the relation between work and total knee replacement (TKR). Two systematic searches in Embase and Medline, supplemented by three systematic reviews. Probably, although evidence is limited, knee OA considerably impairs participation in work (labour force participation, work attendance and work productivity). AREAS OF UNCERTAINTY/RESEARCH NEED: Little is known about effective interventions (treatments, work changes and policies) to improve vocational participation in patients with knee OA; or how type of work affects long-term clinical outcomes (e.g. pain, function and the need for revision surgery) in patients with TKRs. The need for such research is pressing and opportune, as increasing numbers of patients with knee OA or TKR expect to work on.

  7. Effects of a Knee Brace With a Patellar Hole Versus Without a Patellar Hole in Patients With Knee Osteoarthritis: A Double-Blind, Randomized Controlled Trial.

    PubMed

    Added, Marco Aurélio Nemitalla; Added, Caroline; Kasawara, Karina Tamy; Rotta, Viviane Perez; de Freitas, Diego Galace

    2017-01-01

    The objective of this study was to observe the immediate effect of a knee brace with a patellar hole versus without a patellar hole on pain perception in patients with knee osteoarthritis. To accomplish this, a double-blind, randomized controlled trial enrolled 108 patients divided into two groups (knee brace with a patellar hole or without a patellar hole). Patients were evaluated by the Visual Analogue Scale (VAS) in order to measure their pain sensation, the Timed Up and Go (TUG) test was used to evaluate their ability to walk, and the 8-m walking test (8MWT) was used to estimate their walking speed. Both groups presented significant reduction in pain perception, higher function of the lower extremities, and greater mobility while wearing a knee brace. However, the patients who wore a knee brace without a patellar hole presented more favorable results than those who wore a knee brace with a patellar hole: a 1.6-point reduction was found versus 1.1 points in the VAS, the patients presented 0.7 s less time versus 0.4 s in the TUG, and the speed was reduced by 1.4 s versus 0.8 s in the 8MWT. Therefore, the knee brace without a patellar hole presented more favorable results when compared with the knee brace with a patellar hole.

  8. Knee Muscular Control During Jump Landing in Multidirections.

    PubMed

    Sinsurin, Komsak; Vachalathiti, Roongtiwa; Jalayondeja, Wattana; Limroongreungrat, Weerawat

    2016-06-01

    Jump landing is a complex movement in sports. While competing and practicing, athletes frequently perform multi-planar jump landing. Anticipatory muscle activity could influence the amount of knee flexion and prepare the knee for dynamic weight bearing such as landing tasks. The aim of the present study was to examine knee muscle function and knee flexion excursion as athletes naturally performed multi-direction jump landing. Eighteen male athletes performed the jump-landing test in four directions: forward (0°), 30° diagonal, 60° diagonal, and lateral (90°). Muscles tested were vastus medialis (VM), vastus lateralis (VL), rectus femoris (RF), semitendinosus (ST), and biceps femoris (BF). A Vicon(TM) 612 workstation collected the kinematic data. An electromyography was synchronized with the Vicon(TM) Motion system to quantify dynamic muscle function. Repeated measure ANOVA was used to analyze the data. Jump-landing direction significantly influenced (P < 0.05) muscle activities of VL, RF, and ST and knee flexion excursion. Jumpers landed with a trend of decreasing knee flexion excursion and ST muscle activity 100 ms before foot contact progressively from forward to lateral directions of jump landing. A higher risk of knee injury might occur during lateral jump landing than forward and diagonal directions. Athletes should have more practice in jump landing in lateral direction to avoid injury. Landing technique with high knee flexion in multi-directions should be taught to jumpers for knee injury prevention.

  9. Carryover effect of hip and knee exercises program on functional performance in individuals with patellofemoral pain syndrome

    PubMed Central

    Ahmed Hamada, Hamada; Hussein Draz, Amira; Koura, Ghada Mohamed; Saab, Ibtissam M.

    2017-01-01

    [Purpose] This study was carried out to investigate the carryover effect of hip and knee exercises program on functional performance (single legged hop test as functional performance test and Kujala score for functional activities). [Subjects and Methods] Thirty patients with patellofemoral pain syndrome were randomly assigned into two equal groups. Group (A) consisted of 15 patients undergoing hip strengthening exercises for four weeks then measuring all variables followed by additional four weeks of knee exercises program then measuring all variables again. Group (B): consisted of 15 patients undergoing knee exercises program for four weeks then measuring all variables followed by additional four weeks of hip strengthening exercises then measuring all variables. Functional abilities and knee muscles performance were assessed using Kujala questionnaire and single legged hop test respectively pre and after the completion of the first 4 weeks then after 8 weeks for both groups. [Results] Significantly increase in Kujala questionnaire in group A compared with group B was observed. While, there were significant increase in single legged hop performance test in group B compared with group A. [Conclusion] Starting with hip exercises improve the performance of subjects more than functional activities while starting with knee exercises improve the functional activities of subjects more than performance. PMID:28878459

  10. Carryover effect of hip and knee exercises program on functional performance in individuals with patellofemoral pain syndrome.

    PubMed

    Ahmed Hamada, Hamada; Hussein Draz, Amira; Koura, Ghada Mohamed; Saab, Ibtissam M

    2017-08-01

    [Purpose] This study was carried out to investigate the carryover effect of hip and knee exercises program on functional performance (single legged hop test as functional performance test and Kujala score for functional activities). [Subjects and Methods] Thirty patients with patellofemoral pain syndrome were randomly assigned into two equal groups. Group (A) consisted of 15 patients undergoing hip strengthening exercises for four weeks then measuring all variables followed by additional four weeks of knee exercises program then measuring all variables again. Group (B): consisted of 15 patients undergoing knee exercises program for four weeks then measuring all variables followed by additional four weeks of hip strengthening exercises then measuring all variables. Functional abilities and knee muscles performance were assessed using Kujala questionnaire and single legged hop test respectively pre and after the completion of the first 4 weeks then after 8 weeks for both groups. [Results] Significantly increase in Kujala questionnaire in group A compared with group B was observed. While, there were significant increase in single legged hop performance test in group B compared with group A. [Conclusion] Starting with hip exercises improve the performance of subjects more than functional activities while starting with knee exercises improve the functional activities of subjects more than performance.

  11. Collateral ligament strains during knee joint laxity evaluation before and after TKA.

    PubMed

    Delport, Hendrik; Labey, Luc; De Corte, Ronny; Innocenti, Bernardo; Vander Sloten, Jos; Bellemans, Johan

    2013-08-01

    Passive knee stability is provided by the soft tissue envelope. There is consensus among orthopedic surgeons that good outcome in Total Knee Arthroplasty requires equal tension in the medial/lateral compartment of the knee joint, as well as equal tension in the flexion/extension gap. The purpose of this study was to quantify the ligament laxity in the normal non-arthritic knee before and after Posterior-Stabilized Total Knee Arthroplasty. We hypothesized that the Medial/Lateral Collateral Ligament shows minimal changes in length when measured directly by extensometers in the native human knee during varus/valgus laxity testing. We also hypothesized that due to differences in material properties and surface geometry, native laxity is difficult to reconstruct using a Posterior-Stabilized Total Knee. Six specimens were used to perform this in vitro cadaver test using extensometers to provide numerical values for laxity and varus-valgus tilting in the frontal plane. This study enabled a precise measurement of varus-valgus laxity as compared with the clinical assessment. The strains in both ligaments in the replaced knee were different from those in the native knee. Both ligaments were stretched in extension, in flexion the Medial Collateral Ligament tends to relax and the Lateral Collateral Ligament remains tight. As material properties and surface geometry of the replaced knee add stiffness to the joint, we recommend to avoid overstuffing the joint, when using this type of Posterior-Stabilized Total Knee Arthroplasty, in order to obtain varus/valgus laxity close to the native joint. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Functional added value of microprocessor-controlled knee joints in daily life performance of Medicare Functional Classification Level-2 amputees.

    PubMed

    Theeven, Patrick; Hemmen, Bea; Rings, Frans; Meys, Guido; Brink, Peter; Smeets, Rob; Seelen, Henk

    2011-10-01

    To assess the effects of using a microprocessor-controlled prosthetic knee joint on the functional performance of activities of daily living in persons with an above-knee leg amputation. To assess the effects of using a microprocessor-controlled prosthetic knee joint on the functional performance of activities of daily living in persons with an above-knee leg amputation. Randomised cross-over trial. Forty-one persons with unilateral above-knee or knee disarticulation limb loss, classified as Medicare Functional Classification Level-2 (MFCL-2). Participants were measured in 3 conditions, i.e. using a mechanically controlled knee joint and two types of microprocessor-controlled prosthetic knee joints. Functional performance level was assessed using a test in which participants performed 17 simulated activities of daily living (Assessment of Daily Activity Performance in Transfemoral amputees test). Performance time was measured and self-perceived level of difficulty was scored on a visual analogue scale for each activity. High levels of within-group variability in functional performance obscured detection of any effects of using a microprocessor-controlled prosthetic knee joint. Data analysis after stratification of the participants into 3 subgroups, i.e. participants with a "low", "intermediate" and "high" functional mobility level, showed that the two higher functional subgroups performed significantly faster using microprocessor-controlled prosthetic knee joints. MFCL-2 amputees constitute a heterogeneous patient group with large variation in functional performance levels. A substantial part of this group seems to benefit from using a microprocessor-controlled prosthetic knee joint when performing activities of daily living.

  13. Impact of a stance phase microprocessor-controlled knee prosthesis on level walking in lower functioning individuals with a transfemoral amputation.

    PubMed

    Eberly, Valerie J; Mulroy, Sara J; Gronley, JoAnne K; Perry, Jacquelin; Yule, William J; Burnfield, Judith M

    2014-12-01

    For individuals with transfemoral amputation, walking with a prosthesis presents challenges to stability and increases the demand on the hip of the prosthetic limb. Increasing age or comorbidities magnify these challenges. Computerized prosthetic knee joints improve stability and efficiency of gait, but are seldom prescribed for less physically capable walkers who may benefit from them. To compare level walking function while wearing a microprocessor-controlled knee (C-Leg Compact) prosthesis to a traditionally prescribed non-microprocessor-controlled knee prosthesis for Medicare Functional Classification Level K-2 walkers. Crossover. Stride characteristics, kinematics, kinetics, and electromyographic activity were recorded in 10 participants while walking with non-microprocessor-controlled knee and Compact prostheses. Walking with the Compact produced significant increase in velocity, cadence, stride length, single-limb support, and heel-rise timing compared to walking with the non-microprocessor-controlled knee prosthesis. Hip and thigh extension during late stance improved bilaterally. Ankle dorsiflexion, knee extension, and hip flexion moments of the prosthetic limb were significantly improved. Improvements in walking function and stability on the prosthetic limb were demonstrated by the K-2 level walkers when using the C-Leg Compact prosthesis. Understanding the impact of new prosthetic designs on gait mechanics is essential to improve prescription guidelines for deconditioned or older persons with transfemoral amputation. Prosthetic designs that improve stability for safety and walking function have the potential to improve community participation and quality of life. © The International Society for Prosthetics and Orthotics 2013.

  14. Correlation and sex differences between ankle and knee cartilage morphology determined by quantitative magnetic resonance imaging

    PubMed Central

    Eckstein, F; Siedek, V; Glaser, C; Al-Ali, D; Englmeier, K; Reiser, M; Graichen, H

    2004-01-01

    Objective: To study the correlation between ankle and knee cartilage morphology to test the hypothesis that knee joint cartilage loss in gonarthritis can be estimated retrospectively using quantitative MRI analysis of the knee and ankle and established regression equations; and to test the hypothesis that sex differences in joint surface area are larger in the knee than the ankle, which may explain the greater incidence of knee osteoarthritis in elderly women than in elderly men. Methods: Sagittal MR images (3D FLASH WE) of the knee and hind foot were acquired in 29 healthy subjects (14 women, 15 men; mean (SD) age, 25 (3) years), with no signs joint disease. Cartilage volume, thickness, and joint surface area were determined in the knee, ankle, and subtalar joint. Results: Knee cartilage volumes and joint surface areas showed only moderate correlations with those of the ankle and subtalar joint (r = 0.33 to 0.81). The correlations of cartilage thickness between the two joints were weaker still (r = –0.05 to 0.53). Sex differences in cartilage morphology at the knee and the ankle were similar, with surface areas being –17.5% to –23.5% lower in women than in men. Conclusions: Only moderate correlations in cartilage morphology of healthy subjects were found between knee and ankle. It is therefore impractical to estimate knee joint cartilage loss a posteriori in cross sectional studies by measuring the hind foot and then applying a scaling factor. Sex differences in cartilage morphology do not explain differences in osteoarthritis incidence between men and women in the knee and ankle. PMID:15479900

  15. Asymptomatic population reference values for three knee patient-reported outcomes measures: evaluation of an electronic data collection system and implications for future international, multi-centre cohort studies.

    PubMed

    McLean, James M; Brumby-Rendell, Oscar; Lisle, Ryan; Brazier, Jacob; Dunn, Kieran; Gill, Tiffany; Hill, Catherine L; Mandziak, Daniel; Leith, Jordan

    2018-05-01

    The aim was to assess whether the Knee Society Score, Oxford Knee Score (OKS) and Knee Injury and Osteoarthritis Outcome Score (KOOS) were comparable in asymptomatic, healthy, individuals of different age, gender and ethnicity, across two remote continents. The purpose of this study was to establish normal population values for these scores using an electronic data collection system. There is no difference in clinical knee scores in an asymptomatic population when comparing age, gender and ethnicity, across two remote continents. 312 Australian and 314 Canadian citizens, aged 18-94 years, with no active knee pain, injury or pathology in the ipsilateral knee corresponding to their dominant arm, were evaluated. A knee examination was performed and participants completed an electronically administered questionnaire covering the subjective components of the knee scores. The cohorts were age- and gender-matched. Chi-square tests, Fisher's exact test and Poisson regression models were used where appropriate, to investigate the association between knee scores, age, gender, ethnicity and nationality. There was a significant inverse relationship between age and all assessment tools. OKS recorded a significant difference between gender with females scoring on average 1% lower score. There was no significant difference between international cohorts when comparing all assessment tools. An electronic, multi-centre data collection system can be effectively utilized to assess remote international cohorts. Differences in gender, age, ethnicity and nationality should be taken into consideration when using knee scores to compare to pathological patient scores. This study has established an electronic, normal control group for future studies using the Knee society, Oxford, and KOOS knee scores. Diagnostic Level II.

  16. The Effects of Comprehensive Warm-Up Programs on Proprioception, Static and Dynamic Balance on Male Soccer Players

    PubMed Central

    Daneshjoo, Abdolhamid; Mokhtar, Abdul Halim; Rahnama, Nader; Yusof, Ashril

    2012-01-01

    Purpose The study investigated the effects of FIFA 11+ and HarmoKnee, both being popular warm-up programs, on proprioception, and on the static and dynamic balance of professional male soccer players. Methods Under 21 year-old soccer players (n = 36) were divided randomly into 11+, HarmoKnee and control groups. The programs were performed for 2 months (24 sessions). Proprioception was measured bilaterally at 30°, 45° and 60° knee flexion using the Biodex Isokinetic Dynamometer. Static and dynamic balances were evaluated using the stork stand test and Star Excursion Balance Test (SEBT), respectively. Results The proprioception error of dominant leg significantly decreased from pre- to post-test by 2.8% and 1.7% in the 11+ group at 45° and 60° knee flexion, compared to 3% and 2.1% in the HarmoKnee group. The largest joint positioning error was in the non-dominant leg at 30° knee flexion (mean error value = 5.047), (p<0.05). The static balance with the eyes opened increased in the 11+ by 10.9% and in the HarmoKnee by 6.1% (p<0.05). The static balance with eyes closed significantly increased in the 11+ by 12.4% and in the HarmoKnee by 17.6%. The results indicated that static balance was significantly higher in eyes opened compared to eyes closed (p = 0.000). Significant improvements in SEBT in the 11+ (12.4%) and HarmoKnee (17.6%) groups were also found. Conclusion Both the 11+ and HarmoKnee programs were proven to be useful warm-up protocols in improving proprioception at 45° and 60° knee flexion as well as static and dynamic balance in professional male soccer players. Data from this research may be helpful in encouraging coaches or trainers to implement the two warm-up programs in their soccer teams. PMID:23251579

  17. Benefit from NASA

    NASA Image and Video Library

    1996-12-17

    A knee brace that uses Space Shuttle propulsion technology has moved a step closer to being available to help knee injury and stroke patients and may possibly benefit patients with birth defects, spinal cord injuries, and post-polio conditions. After years of hard work, inventors at NASA's Marshall Space Flight Center (MSFC) in Huntsville, Alabama, have turned over the final design and prototype to industry partners at Horton's Orthotic Lab in Little Rock, Arkansas for further clinical testing. The device, called the Selectively Lockable Knee Brace, may mean faster, less painful rehabilitation for patients by allowing the knee to move when weight is not on the heel. Devices currently on the market lock the knee in a rigid, straight-leg position, or allow continuous free motion. Pictured here is a knee brace prototype being tested and fitted at Horton's Orthotic Lab. The knee brace is just one example of how space technology is being used to improve the lives of people on Earth. NASA's MSFC inventors Michael Shadoan and Neill Myers are space propulsion engineers who use the same mechanisms and materials to build systems for rockets that they used to design and develop the knee brace.

  18. Standardising the clinical assessment of coronal knee laxity.

    PubMed

    Clarke, Jon V; Wilson, William T; Wearing, Scott C; Picard, Frederic; Riches, Philip E; Deakin, Angela H

    2012-09-01

    Clinical laxity tests are used for assessing knee ligament injuries and for soft tissue balancing in total knee arthroplasty. This study reports the development and validation of a quantitative technique of assessing collateral knee laxity through accurate measurement of potential variables during routine clinical examination. The hypothesis was that standardisation of a clinical stress test would result in a repeatable range of laxity measurements. Non-invasive infrared tracking technology with kinematic registration of joint centres gave real-time measurement of both coronal and sagittal mechanical tibiofemoral alignment Knee flexion, moment arm and magnitude of the applied force were all measured and standardised. Three clinicians then performed six knee laxity examinations on a single volunteer using a target moment of 18 Nm. Standardised laxity measurements had small standard deviations (within 1. 1 degree) for each clinician and similar mean values between clinicians, with the valgus laxity assessment (mean of 3 degrees) being slightly more consistent than varus (means of 4 degrees or 5 degrees). The manual technique of coronal knee laxity assessment was successfully quantified and standardised, leading to a narrow range of measurements (within the accuracy of the measurement system). Minimising the subjective variables of clinical examination could improve current knowledge of soft tissue knee behaviour.

  19. Computer-assisted measurements of coronal knee joint laxity in vitro are related to low-stress behavior rather than structural properties of the collateral ligaments.

    PubMed

    Wilson, W T; Deakin, A H; Wearing, S C; Payne, A P; Clarke, J V; Picard, F

    2013-01-01

    The relationship between coronal knee laxity and the restraining properties of the collateral ligaments remains unknown. This study investigated correlations between the structural properties of the collateral ligaments and stress angles used in computer-assisted total knee arthroplasty (TKA), measured with an optically based navigation system. Ten fresh-frozen cadaveric knees (mean age: 81 ± 11 years) were dissected to leave the menisci, cruciate ligaments, posterior joint capsule and collateral ligaments. The resected femur and tibia were rigidly secured within a test system which permitted kinematic registration of the knee using a commercially available image-free navigation system. Frontal plane knee alignment and varus-valgus stress angles were acquired. The force applied during varus-valgus testing was quantified. Medial and lateral bone-collateral ligament-bone specimens were then prepared, mounted within a uni-axial materials testing machine, and extended to failure. Force and displacement data were used to calculate the principal structural properties of the ligaments. The mean varus laxity was 4 ± 1° and the mean valgus laxity was 4 ± 2°. The corresponding mean manual force applied was 10 ± 3 N and 11 ± 4 N, respectively. While measures of knee laxity were independent of the ultimate tensile strength and stiffness of the collateral ligaments, there was a significant correlation between the force applied during stress testing and the instantaneous stiffness of the medial (r = 0.91, p = 0.001) and lateral (r = 0.68, p = 0.04) collateral ligaments. These findings suggest that clinicians may perceive a rate of change of ligament stiffness as the end-point during assessment of collateral knee laxity.

  20. Quantitative comparison of the pivot shift test results before and after anterior cruciate ligament reconstruction by using the three-dimensional electromagnetic measurement system.

    PubMed

    Nagai, Kanto; Hoshino, Yuichi; Nishizawa, Yuichiro; Araki, Daisuke; Matsushita, Takehiko; Matsumoto, Tomoyuki; Takayama, Koji; Nagamune, Kouki; Kurosaka, Masahiro; Kuroda, Ryosuke

    2015-10-01

    Tibial acceleration during the pivot shift test is a potential quantitative parameter to evaluate rotational laxity of anterior cruciate ligament (ACL) insufficiency. However, clinical application of this measurement has not been fully examined. This study aimed to measure and compare tibial acceleration before and after ACL reconstruction (ACLR) in ACL-injured patients. We hypothesized tibial acceleration would be reduced by ACLR and tibial acceleration would be consistent in the same knee at different time points. Seventy ACL-injured patients who underwent ACLR were enrolled. Tibial acceleration during the pivot shift test was measured using an electromagnetic measurement system before ALCR and at the second-look arthroscopy 1 year post-operatively. Tibial acceleration was compared to clinical grading and between ACL-injured/ACL-reconstructed and contralateral knees. Pre-operative tibial acceleration was increased stepwise with the increase in clinical grading (P < 0.01). Tibial acceleration in ACL-injured knee (1.9 ± 1.2 m/s(2)) was larger than that in the contralateral knee (0.8 ± 0.3 m/s(2), P < 0.01), and reduced to 0.9 ± 0.3 m/s(2) post-operatively (P < 0.01). There was no difference between ACL-reconstructed and contralateral knee (n.s.). Tibial acceleration in contralateral knees was consistent pre- and post-operatively (n.s.). Tibial acceleration measurement demonstrated increased rotational laxity in ACL-injured knees and its reduction by ALCR. Additionally, consistent measurements were obtained in ACL-intact knees at different time points. Therefore, tibial acceleration during the pivot shift test could provide quantitative evaluation of rotational stability before and after ACL reconstruction. III.

  1. RSA and registries: the quest for phased introduction of new implants.

    PubMed

    Nelissen, Rob G H H; Pijls, Bart G; Kärrholm, Johan; Malchau, Henrik; Nieuwenhuijse, Marc J; Valstar, Edward R

    2011-12-21

    Although the overall survival of knee and hip prostheses at ten years averages 90%, recent problems with several hip and knee prostheses have illustrated that the orthopaedic community, industry, and regulators can still further improve patient safety. Given the early predictive properties of roentgen stereophotogrammetric analysis (RSA) and the meticulous follow-up of national joint registries, these two methods are ideal tools for such a phased clinical introduction. In this paper, we elaborate on the predictive power of RSA within a two-year follow-up after arthroplasty and its relationship to national joint registries. The association between RSA prosthesis-migration data and registry data is evaluated. The five-year rate of revision of RSA-tested total knee replacements was compared with that of non-RSA-tested total knee replacements. Data were extracted from the published results of the national joint registries of Sweden, Australia, and New Zealand. There was a 22% to 35% reduction in the number of revisions of RSA-tested total knee replacements as compared with non-RSA-tested total knee replacements in the national joint registries. Assuming that the total cost of total knee arthroplasty is $37,000 in the United States, a 22% to 35% reduction in the number of revisions (currently close to 55,000 annually) could lead to an estimated annual savings of over $400 million to the health-care system. The phased clinical introduction of new prostheses with two-year RSA results as a qualitative tool could lead to better patient care and could reduce the costs associated with revision total knee arthroplasty. Follow-up in registries is necessary to substantiate these results and to improve post-market surveillance.

  2. OpenSim as a preliminary kinematic testing platform for the development of total knee arthroplasty implants.

    PubMed

    Chan, Hao Yang; Walker, Peter S

    2018-05-18

    The design of a total knee replacement implant needs to take account the complex surfaces of the knee which it is replacing. Ensuring design performance of the implant requires in vitro testing of the implant. A considerable amount of time is required to produce components and evaluate them inside an experimental setting. Numerous adjustments in the design of an implant and testing each individual design can be time consuming and expensive. Our solution is to use the OpenSim simulation software to rapidly test multiple design configurations of implants. This study modeled a testing rig which characterized the motion and laxity of knee implants. Three different knee implant designs were used to test and validate the accuracy of the simulation: symmetrical, asymmetric, and anatomic. Kinematics were described as distances measured from the center of each femoral condyle to a plane intersecting the most posterior points of the tibial condyles between 0 and 135° of flexion with 15° increments. Excluding the initial flexion measurement (∼0°) results, the absolute differences between all experimental and simulation results (neutral path, anterior-posterior shear, internal-external torque) for the symmetric, asymmetric, and anatomical designs were 1.98 mm ± 1.15, 1.17 mm ± 0.89, and 1.24 mm ± 0.97, respectively. Considering all designs, the accuracy of the simulation across all tests was 1.46 mm ± 1.07. It was concluded that the results of the simulation were an acceptable representation of the testing rig and hence applicable as a design tool for new total knees. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Changes in self-reported disability after performance-based tests in obese and non-obese individuals diagnosed with osteoarthritis of the knee.

    PubMed

    Coriolano, Kamary; Aiken, Alice; Pukall, Caroline; Harrison, Mark

    2015-01-01

    The purposes of this study are three-fold: (1) To examine whether the WOMAC questionnaire should be obtained before or after performance-based tests. (2) To assess whether self-reported disability scores before and after performance-based tests differ between obese and non-obese individuals. (3) To observe whether physical activity and BMI predict self-reported disability before and after performance based tests. A longitudinal study included thirty one participants diagnosed with knee osteoarthritis (OA) using the Kellgren-Lawrence Scale by an orthopedic surgeon. All WOMAC scores were significantly higher after as compared to before the completion of performance-based tests. This pattern of results suggested that the WOMAC questionnaire should be administered to individuals with OA after performance-based tests. The obese OA was significantly different compared to the non-obese OA group on all WOMAC scores. Physical activity and BMI explained a significant proportion of variance of self-reported disability. Obese individuals with knee OA may over-estimate their ability to perform physical activities, and may under-estimate their level of disability compared to non-obese individuals with knee OA. In addition, self-reported physical activity seems to be a strong indicator of disability in individuals with knee OA, particularly for individuals with a sedentary life style. Implications for Rehabilitation Osteoarthritis is a progressive joint disabling condition that restricts physical function and participation in daily activities, particularity in elderly individuals. Obesity is a comorbidity commonly associated with osteoarthritis and it appears to increase self-reported disability in those diagnosed with osteoarthritis of the knee. In a relatively small sample, this study recommends that rehabilitation professionals obtain self-report questionnaires of disability after performance-based tests in obese individuals with osteoarthritis of the knee as they are more likely to give an accurate representation of their level of ability at this time.

  4. Transcultural adaptation and validation of the “Hip and Knee” questionnaire into Spanish

    PubMed Central

    2014-01-01

    Background The purpose of the present study is to translate and validate the “Hip and Knee Outcomes Questionnaire”, developed in English, into Spanish. The ‘Hip and Knee Outcomes Questionnaire is a questionnaire planned to evaluate the impact in quality of life of any problem related to the human musculoskeletal system. 10 scientific associations developed it. Methods The questionnaire underwent a validated translation/retro-translation process. Patients undergoing primary knee arthroplasty, before and six months postoperative, tested the final version in Spanish. Psychometric properties of feasibility, reliability, validity and sensitivity to change were assessed. Convergent validity with SF-36 and WOMAC questionnaires was evaluated. Results 316 patients were included. Feasibility: a high number of missing items in questions 3, 4 and 5 were observed. The number of patients with a missing item was 171 (51.35%) in the preoperative visit and 139 (44.0%) at the postoperative. Internal validity: revision of coefficients in the item-rest correlation recommended removing question 6 during the preoperative visit (coefficient <0.20). Convergent validity: coefficients of correlation with WOMAC and SF-36 scales confirm the questionnaire’s validity. Sensitivity to change: statistically significant differences were found between the mean scores of the first visit compared to the postoperative. Conclusion The proposed translation to Spanish of the ‘Hip and Knee Questionnaire’ is found to be reliable, valid and sensible to changes produced at the clinical practice of patients undergoing primary knee arthroplasty. However, some changes at the completion instructions are recommended. Level of evidence: Level I. Prognostic study. PMID:24885248

  5. Routine clinical knee MR reports: comparison of diagnostic performance at 1.5 T and 3.0 T for assessment of the articular cartilage.

    PubMed

    Mandell, Jacob C; Rhodes, Jeffrey A; Shah, Nehal; Gaviola, Glenn C; Gomoll, Andreas H; Smith, Stacy E

    2017-11-01

    Accurate assessment of knee articular cartilage is clinically important. Although 3.0 Tesla (T) MRI is reported to offer improved diagnostic performance, literature regarding the clinical impact of MRI field strength is lacking. The purpose of this study is to compare the diagnostic performance of clinical MRI reports for assessment of cartilage at 1.5 and 3.0 T in comparison to arthroscopy. This IRB-approved retrospective study consisted of 300 consecutive knees in 297 patients who had routine clinical MRI and arthroscopy. Descriptions of cartilage from MRI reports of 165 knees at 1.5 T and 135 at 3.0 T were compared with arthroscopy. The sensitivity, specificity, percent of articular surfaces graded concordantly, and percent of articular surfaces graded within one grade of the arthroscopic grading were calculated for each articular surface at 1.5 and 3.0 T. Agreement between MRI and arthroscopy was calculated with the weighted-kappa statistic. Significance testing was performed utilizing the z-test after bootstrapping to obtain the standard error. The sensitivity, specificity, percent of articular surfaces graded concordantly, and percent of articular surfaces graded within one grade were 61.4%, 82.7%, 62.2%, and 77.5% at 1.5 T and 61.8%, 80.6%, 59.5%, and 75.6% at 3.0 T, respectively. The weighted kappa statistic was 0.56 at 1.5 T and 0.55 at 3.0 T. There was no statistically significant difference in any of these parameters between 1.5 and 3.0 T. Factors potentially contributing to the lack of diagnostic advantage of 3.0 T MRI are discussed.

  6. Osteoarthritis in veterans undergoing bariatric surgery is associated with decreased excess weight loss: 5-year outcomes.

    PubMed

    Kubat, Eric; Giori, Nicholas J; Hwa, Kimberly; Eisenberg, Dan

    2016-08-01

    Obesity exacerbates pre-existing musculoskeletal disease and joint pain. This may limit physical activity in obese individuals. We sought to identify the disease burden and impact of osteoarthritis of the lumbar back, hip, knee, and ankle in veterans undergoing bariatric surgery. Veterans Affairs medical center. Retrospective review of a prospective bariatric database of operations performed at a single Veterans Affairs medical center. Patients with osteoarthritis of the lumbar spine, hip, knee, or ankle were identified and diagnosis confirmed by electronic health record review of prior radiographic reports. Analysis was performed using χ 2 test for continuous variables. Student's t test and one-way analysis of variance were used to compare qualitative variables. Of 254 bariatric surgical patients, 83.9% had preoperative musculoskeletal pain before bariatric surgery and 59.1% had a confirmed diagnosis of osteoarthritis of the lumbar spine, hips, knees, and/or ankles. Follow-up rate was 97.4%, 85.4%, and 82.6% at 1, 3, and 5 years respectively. Of patients with osteoarthritis, 58.6% had knee involvement and 46% had multiple sites involved. In the cohort without osteoarthritis, percent excess body mass index loss was 66.9% at 1 year versus 58.5% in the cohort with osteoarthritis (P = .009), 66.1% versus 51.9% (P = .001) at 3 years, and 64.3% versus 50.1% (P = .002) after 5 years. Percent total weight loss was 28.4% versus 25.2%, 28.0% versus 22.8%, and 27.1% versus 22.4%, respectively, at 1, 3, and 5 years. Osteoarthritis is common among veterans undergoing bariatric surgery. It is associated with significantly less weight loss compared to veterans who do not have osteoarthritis, up to 5 years after bariatric surgery. Published by Elsevier Inc.

  7. Comparison of mobility and user satisfaction between a microprocessor knee and a standard prosthetic knee: a summary of seven single-subject trials.

    PubMed

    Howard, Charla L; Wallace, Chris; Perry, Bonnie; Stokic, Dobrivoje S

    2018-03-01

    Insufficient evidence of the benefits provided by costlier microprocessor knees (MPKs) over nonmicroprocessor knees (NMPKs) often causes concern when considering MPK prescription. Thus, more studies are needed to demonstrate differences between MPKs and NMPKs and define sensitive outcomes to guide MPK prescription. The aim of this study was to evaluate the impact of switching from NMPK to MPK on measures of mobility and preference. Seven long-term NMPK users (all men, ages 50-84, 3-64 years postamputation) participated in this study, which use a single-subject design (ABA or BAB; A=NMPK, B=MPK). Mobility was assessed with the Amputee Mobility Predictor, Berg Balance Scale (BBS), L-Test, 6-Min Walk Test (6MWT) with Physiological Cost Index, and self-selected normal and very fast gait speeds. The preference between NMPK and MPK was evaluated by the Prosthesis Evaluation Questionnaire (PEQ) and the visual analog scale. Mobility improved with the MPK in six of seven participants, which was most often captured with BBS (median: +6 points) and 6MWT (median: +63 m). These improvements typically exceeded minimal clinically important difference or minimal detectable change thresholds. Most participants scored the MPK higher on the PEQ (median: +20 points) and six of seven expressed a global preference toward MPK. In the BAB group, the Amputee Mobility Predictor and BBS correlated with perception of change on several PEQ domains (Ρ≥0.59). In conclusion, MPKs may provide better outcomes and user satisfaction, particularly in those with lower mobility function. BBS and 6MWT were found to be the most sensitive measures to capture changes in mobility while using MPK for several weeks.

  8. Gait and balance of transfemoral amputees using passive mechanical and microprocessor-controlled prosthetic knees.

    PubMed

    Kaufman, K R; Levine, J A; Brey, R H; Iverson, B K; McCrady, S K; Padgett, D J; Joyner, M J

    2007-10-01

    Microprocessor-controlled knee joints appeared on the market a decade ago. These joints are more sophisticated and more expensive than mechanical ones. The literature is contradictory regarding changes in gait and balance when using these sophisticated devices. This study employed a crossover design to assess the comparative performance of a passive mechanical knee prosthesis compared to a microprocessor-controlled knee joint in 15 subjects with an above-knee amputation. Objective measurements of gait and balance were obtained. Subjects demonstrated significantly improved gait characteristics after receiving the microprocessor-controlled prosthetic knee joint (p<0.01). Improvements in gait were a transition from a hyperextended knee to a flexed knee during loading response which resulted in a change from an internal knee flexor moment to a knee extensor moment. The participants' balance also improved (p<0.01). All conditions of the Sensory Organization Test (SOT) demonstrated improvements in equilibrium score. The composite score also increased. Transfemoral amputees using a microprocessor-controlled knee have significant improvements in gait and balance.

  9. Impact of a Focused Approach for Discharge Teaching Regarding the Use of Aspirin as Anticoagulant After Joint Replacement Surgery.

    PubMed

    Wittig-Wells, Deborah; Higgins, Melinda; Davis, Erica; Johnson, Ifeya; Louis, Latalya; Mason, Olga; Samms-McPherson, Jacqueline; Sims, Sandra; Jacob, Ani

    2015-01-01

    Patient education for the use and administration of aspirin (ASA) as an anticoagulant may be deficient. To pilot a knowledge assessment tool regarding the use of aspirin (ASA) as an anticoagulant and to evaluate the impact of a focused approach for discharge teaching. One-group pretest-posttest pilot study. Convenience sample of patients hospitalized for total knee and total hip arthroplasty. Researcher developed ASA quiz. Focused education on aspirin as an anticoagulant. There was a statistically significant improvement in knowledge (Wilcoxon rank sum test Z = 3.880, p < .001).

  10. Validation of a global assessment of arthroscopic skills in a cadaveric knee model.

    PubMed

    Slade Shantz, Jesse A; Leiter, Jeff R; Collins, John B; MacDonald, Peter B

    2013-01-01

    The purpose of this study was to determine whether a global assessment of arthroscopic skills was valid for blinded assessment of cadaveric diagnostic knee arthroscopy. A global skills assessment for arthroscopy was created using a published theory of the development of expertise. Faculty surgeons, fellows, and residents were consented and enrolled in this institutional review board-approved validation study. All participants were oriented to the equipment and procedures for diagnostic arthroscopy of the knee. After reviewing the anatomic structures to be visualized, participants were allowed 10 minutes to complete a diagnostic arthroscopy of the knee. The hands and arthroscopic view were recorded during this attempt. Resident participants completed a second filmed diagnostic arthroscopy 1 week after the initial attempt. Five blinded reviewers watched the synchronized videos and assessed arthroscopic skills with a procedure-specific checklist and the newly developed global skills assessment. The agreement between reviewers was determined by intraclass correlation coefficient. Internal consistency was determined with Cronbach's α. Test-retest reliability was measured by correlating repeated arthroscopies by residents. The ability of the global assessment to discriminate skill levels was determined with between-group Mann-Whitney U tests. The agreement between global assessment scores was strong (I.C.C. = 0.80, 95% C.I. 0.68-0.92). The internal consistency of evaluations was excellent (Cronbach's α = 0.97), and the test-retest reliability was strong (r = 0.52). The global assessment score was shown to be able to discriminate between skill levels by an analysis of variance indicating the difference in means among the various levels of training (P < .0001). The Objective Assessment of Arthroscopic Skills is a useful adjunct to arthroscopic educators and learners and could be used for in-training evaluations. The Objective Assessment of Arthroscopic Skills is an instrument that can be employed to measure the impact of skills curricula, including but not limited to simulation. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  11. Rehospitalizations, early revisions, infections, and hospital resource use in the first year after hip and knee arthroplasties.

    PubMed

    Bohm, Eric R; Dunbar, Michael J; Frood, Jennifer J; Johnson, Tracy M; Morris, Kathleen A

    2012-02-01

    We examined 3 negative outcomes for 58 351 hip and knee arthroplasty patients: rehospitalization, revision and infection, and their impact on resource use in the year after surgery. In the year before surgery, 12.9% of elective hip and 10.2% of knee patients were hospitalized. In the year after, 14.8% of elective hip and 15.5% of knee patients were hospitalized, representing a 15% and 52% increase, respectively. Twenty-eight percent of emergent hip patients were hospitalized at least once preoperatively; this did not change after surgery. Revision occurred in 2.0% of emergent hip, 1.7% of elective hip, and 0.9% of knee patients. Joint infection was diagnosed in 1.3% of patients. The increased hospitalization after the elective hip and knee procedures represents an incremental cost of 10% over the index hospital stay. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Dynamic impact force and association with structural damage to the knee joint: an ex-vivo study.

    PubMed

    Brill, Richard; Wohlgemuth, Walther A; Hempfling, Harald; Bohndorf, Klaus; Becker, Ursula; Welsch, Ulrich; Kamp, Alexander; Roemer, Frank W

    2014-12-01

    No systematic, histologically confirmed data are available concerning the association between magnitude of direct dynamic impact caused by vertical impact trauma and the resulting injury to cartilage and subchondral bone. The aim of this study was to investigate the association between dynamic impact and the resulting patterns of osteochondral injury in an ex-vivo model. A mechanical apparatus was employed to perform ex-vivo controlled dynamic vertical impact experiments in 110 pig knees with the femur positioned in a holding fixture. A falling body with a thrust plate and photo sensor was applied. The direct impact to the trochlear articular surface was registered and the resulting osteochondral injuries macroscopically and histologically correlated and categorized. The relationship between magnitude of direct impact and injury severity could be classified as stage I injuries (impact <7.3MPa): elastic deformation, no histological injury; stage II injuries (impact 7.3-9.6MPa): viscoelastic imprint of the cartilaginous surface, subchondral microfractures; stage III injuries (impact 9.6-12.7MPa): disrupted cartilage surface, chondral fissures and subchondral microfractures; stage IV injuries (impact >12.7MPa): osteochondral impression, histologically imprint and osteochondral macrofractures. The impact ranges and histologic injury stages determined from this vertical dynamic impact experiment allowed for a biomechanical classification of direct, acute osteochondral injury. In contrast to static load commonly applied in ex-vivo experiments, dynamic impact more realistically represents actual trauma to the knee joint.

  13. A knee-mounted biomechanical energy harvester with enhanced efficiency and safety

    NASA Astrophysics Data System (ADS)

    Chen, Chao; Chau, Li Yin; Liao, Wei-Hsin

    2017-06-01

    Energy harvesting is becoming a major limiting issue for many portable devices. When undertaking any activity, the human body generates a significant amount of biomechanical energy, which can be collected by means of a portable energy harvester. This energy provides a method of powering portable devices such as prosthetic limbs. In this paper, a knee-mounted energy harvester with enhanced efficiency and safety is proposed and developed to convert mechanical energy into electricity during human motion. This device can change the bi-directional knee input into uni-directional rotation for an electromagnetic generator using a specially designed transmission system. Without the constraint of induced impact on the human body, this device can harvest biomechanical energy from both knee flexion and extension, improving the harvesting efficiency over previous single-direction energy harvesters. It can also provide protection from device malfunction, and increase the safety of current biomechanical energy harvesters. A highly compact and light prototype is developed taking into account human kinematics. The biomechanical energy harvesting system is also modeled and analyzed. The prototype is tested under different conditions including walking, running and climbing stairs, to evaluate the energy harvesting performance and effect on the human gait. The experimental results show that the prototype can harvest an average power of 3.6 W at 1.5 m s-1 walking speed, which is promising for portable electronic devices.

  14. Relationship between lower limb dynamics and knee joint pain.

    PubMed

    Radin, E L; Yang, K H; Riegger, C; Kish, V L; O'Connor, J J

    1991-05-01

    To test the hypothesis that appropriate and timely neuromuscular control of limb motions plays an important role in the preservation of joint health, we kinematically and kinetically examined the behavior of the legs of young adult subjects at heel strike during natural walking. We compared a group of 18 volunteers, who, we presumed, were preosteoarthrotic because of mild, intermittent, activity-related knee joint pain, with 14 age-matched asymptomatic normal subjects. The two groups of subjects exhibited similar gait patterns with equivalent cadences, walking speeds, terminal stance phase knee flexion, maximum (peak) swing angular velocity, and overall shape of the vertical ground reaction. However, our instrumentation detected statistically significant differences between the two groups within a few milliseconds of heel strike. In the knee pain group, the heel hit the floor with a stronger impact in this brief interval. Just before heel strike, there was a faster downward velocity of the ankle with a larger angular velocity of the shank. The follow-through of the leg immediately after heel strike was more violent with larger peak axial and angular accelerations of the leg echoed by a more rapid rise of the ground reaction force. This sequence of events represents repetitive impulsive loading, which consistently provoked osteoarthrosis in animal experiments. We refer to this micro-incoordination of neuromuscular control not visible to the naked eye as "microklutziness."

  15. Preoperative methylprednisolone does not reduce loss of knee-extension strength after total knee arthroplastyA randomized, double-blind, placebo-controlled trial of 61 patients.

    PubMed

    Lindberg-Larsen, Viktoria; Bandholm, Thomas Q; Zilmer, Camilla K; Bagger, Jens; Hornsleth, Mette; Kehlet, Henrik

    2017-10-01

    Background and purpose - Patients undergoing total knee arthroplasty (TKA) face challenges related to postoperative reduction in knee-extension strength. We evaluated whether inhibition of the inflammatory response by a single preoperative dose of methylprednisolone (MP) reduces the pronounced loss of knee-extension strength at discharge after fast-track TKA. Patients and methods - 70 patients undergoing elective unilateral TKA were randomized (1:1) to preoperative intravenous (IV) MP 125 mg (group MP) or isotonic saline IV (group C). All procedures were performed under spinal anesthesia without tourniquet, and with a standardized multimodal analgesic regime. The primary outcome was change in knee-extension strength from baseline to 48 hours postoperatively. Secondary outcomes were knee joint circumference, functional performance using the Timed Up and Go (TUG) test, pain during the aforementioned tests, rescue analgesic requirements, and plasma C-reactive protein (CRP) changes. Results - 61 patients completed the follow-up. The loss in quadriceps muscle strength was similar between groups; group MP 1.04 (0.22-1.91) Nm/kg (-89%) vs. group C 1.02 (0.22-1.57) Nm/kg (-88%). Also between-group differences were similar for knee circumference, TUG test, and pain scores. MP reduced the inflammatory response (CRP) at 24 hours postoperatively; group MP 33 (IQR 21-50) mg/L vs. group C 72 (IQR 58-92) mg/L (p < 0.001), and 48 hours postoperatively; group MP 83 (IQR 56-125) mg/L vs. group C 192 (IQR 147-265) mg/L (p < 0.001), respectively. Interpretation - Preoperative systemic administration of MP 125 mg did not reduce the pronounced loss of knee-extension strength or other functional outcomes at discharge after fast-track TKA despite a reduced systemic inflammatory response.

  16. Preoperative methylprednisolone does not reduce loss of knee-extension strength after total knee arthroplasty

    PubMed Central

    Lindberg-Larsen, Viktoria; Bandholm, Thomas Q; Zilmer, Camilla K; Bagger, Jens; Hornsleth, Mette; Kehlet, Henrik

    2017-01-01

    Background and purpose Patients undergoing total knee arthroplasty (TKA) face challenges related to postoperative reduction in knee-extension strength. We evaluated whether inhibition of the inflammatory response by a single preoperative dose of methylprednisolone (MP) reduces the pronounced loss of knee-extension strength at discharge after fast-track TKA. Patients and methods 70 patients undergoing elective unilateral TKA were randomized (1:1) to preoperative intravenous (IV) MP 125 mg (group MP) or isotonic saline IV (group C). All procedures were performed under spinal anesthesia without tourniquet, and with a standardized multimodal analgesic regime. The primary outcome was change in knee-extension strength from baseline to 48 hours postoperatively. Secondary outcomes were knee joint circumference, functional performance using the Timed Up and Go (TUG) test, pain during the aforementioned tests, rescue analgesic requirements, and plasma C-reactive protein (CRP) changes. Results 61 patients completed the follow-up. The loss in quadriceps muscle strength was similar between groups; group MP 1.04 (0.22–1.91) Nm/kg (–89%) vs. group C 1.02 (0.22–1.57) Nm/kg (–88%). Also between-group differences were similar for knee circumference, TUG test, and pain scores. MP reduced the inflammatory response (CRP) at 24 hours postoperatively; group MP 33 (IQR 21–50) mg/L vs. group C 72 (IQR 58–92) mg/L (p < 0.001), and 48 hours postoperatively; group MP 83 (IQR 56–125) mg/L vs. group C 192 (IQR 147–265) mg/L (p < 0.001), respectively. Interpretation Preoperative systemic administration of MP 125 mg did not reduce the pronounced loss of knee-extension strength or other functional outcomes at discharge after fast-track TKA despite a reduced systemic inflammatory response. PMID:28657396

  17. Reliability and validity of the Performance Recorder 1 for measuring isometric knee flexor and extensor strength.

    PubMed

    Neil, Sarah E; Myring, Alec; Peeters, Mon Jef; Pirie, Ian; Jacobs, Rachel; Hunt, Michael A; Garland, S Jayne; Campbell, Kristin L

    2013-11-01

    Muscular strength is a key parameter of rehabilitation programs and a strong predictor of functional capacity. Traditional methods to measure strength, such as manual muscle testing (MMT) and hand-held dynamometry (HHD), are limited by the strength and experience of the tester. The Performance Recorder 1 (PR1) is a strength assessment tool attached to resistance training equipment and may be a time- and cost-effective tool to measure strength in clinical practice that overcomes some limitations of MMT and HHD. However, reliability and validity of the PR1 have not been reported. Test-retest and inter-rater reliability was assessed using the PR1 in healthy adults (n  =  15) during isometric knee flexion and extension. Criterion-related validity was assessed through comparison of values obtained from the PR1 and Biodex® isokinetic dynamometer. Test-retest reliability was excellent for peak knee flexion (intra-class correlation coefficient [ICC] of 0.96, 95% CI: 0.85, 0.99) and knee extension (ICC  =  0.96, 95% CI: 0.87, 0.99). Inter-rater reliability was also excellent for peak knee flexion (ICC  =  0.95, 95% CI: 0.85, 0.99) and peak knee extension (ICC  =  0.97, 95% CI: 0.91, 0.99). Validity was moderate for peak knee flexion (ICC  =  0.75, 95% CI: 0.38, 0.92) but poor for peak knee extension (ICC  =  0.37, 95% CI: 0, 0.73). The PR1 provides a reliable measure of isometric knee flexor and extensor strength in healthy adults that could be used in the clinical setting, but absolute values may not be comparable to strength assessment by gold-standard measures.

  18. Knee Injury and Osteoarthritis Outcome Score (KOOS): systematic review and meta-analysis of measurement properties.

    PubMed

    Collins, N J; Prinsen, C A C; Christensen, R; Bartels, E M; Terwee, C B; Roos, E M

    2016-08-01

    To conduct a systematic review and meta-analysis to synthesize evidence regarding measurement properties of the Knee injury and Osteoarthritis Outcome Score (KOOS). A comprehensive literature search identified 37 eligible papers evaluating KOOS measurement properties in participants with knee injuries and/or osteoarthritis (OA). Methodological quality was evaluated using the COSMIN checklist. Where possible, meta-analysis of extracted data was conducted for all studies and stratified by age and knee condition; otherwise narrative synthesis was performed. KOOS has adequate internal consistency, test-retest reliability and construct validity in young and old adults with knee injuries and/or OA. The ADL subscale has better content validity for older patients and Sport/Rec for younger patients with knee injuries, while the Pain subscale is more relevant for painful knee conditions. The five-factor structure of the original KOOS is unclear. There is some evidence that the KOOS subscales demonstrate sufficient unidimensionality, but this requires confirmation. Although measurement error requires further evaluation, the minimal detectable change for KOOS subscales ranges from 14.3 to 19.6 for younger individuals, and ≥20 for older individuals. Evidence of responsiveness comes from larger effect sizes following surgical (especially total knee replacement) than non-surgical interventions. KOOS demonstrates adequate content validity, internal consistency, test-retest reliability, construct validity and responsiveness for age- and condition-relevant subscales. Structural validity, cross-cultural validity and measurement error require further evaluation, as well as construct validity of KOOS Physical function Short form. Suggested order of subscales for different knee conditions can be applied in hierarchical testing of endpoints in clinical trials. PROSPERO (CRD42011001603). Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  19. Lumbopelvic motor control and low back pain in elite soccer players: a cross-sectional study.

    PubMed

    Grosdent, Stéphanie; Demoulin, Christophe; Rodriguez de La Cruz, Carlos; Giop, Romain; Tomasella, Marco; Crielaard, Jean-Michel; Vanderthommen, Marc

    2016-01-01

    This study aimed to investigate the relationship between the history of low back pain and quality of lumbopelvic motor control in soccer players. Forty-three male elite soccer players (mean age, 18.2 ± 1.4 years) filled in questionnaires related to low back pain and attended a session to assess lumbopelvic motor control by means of five tests (the bent knee fall out test, the knee lift abdominal test, the sitting knee extension test, the waiter's bow and the transversus abdominis test). A physiotherapist, blinded to the medical history of the participants, scored (0 = failed, 1 = correct) the performance of the players for each of the tests resulting in a lumbopelvic motor control score ranging from 0 to 5. Forty-seven per cent of the soccer players reported a disabling low back pain episode lasting at least two consecutive days in the previous year. These players scored worse lumbopelvic motor control than players without a history of low back pain (lumbopelvic motor control score of 1.8 vs. 3.3, P < 0.01). The between-groups difference was particularly marked for the bent knee fall out test, the knee lift abdominal test and the transversus abdominis test (P < 0.01). In conclusion, most soccer players with a history of low back pain had an altered lumbopelvic motor control. Further research should examine whether lumbopelvic motor control is etiologically involved in low back pain episodes in soccer players.

  20. Cryotherapy impairs knee joint position sense.

    PubMed

    Oliveira, R; Ribeiro, F; Oliveira, J

    2010-03-01

    The effects of cryotherapy on joint position sense are not clearly established; however it is paramount to understand its impact on peripheral feedback to ascertain the safety of using ice therapy before resuming exercise on sports or rehabilitation settings. Thus, the aim of the present study was to determine the effects of cryotherapy, when applied over the quadriceps and over the knee joint, on knee position sense. This within-subjects repeated-measures study encompassed fifteen subjects. Knee position sense was measured by open kinetic chain technique and active positioning at baseline and after cryotherapy application. Knee angles were determined by computer analysis of the videotape images. Twenty-minute ice bag application was applied randomly, in two sessions 48 h apart, over the quadriceps and the knee joint. The main effect for cryotherapy application was significant (F (1.14)=7.7, p=0.015) indicating an increase in both absolute and relative angular errors after the application. There was no significant main effect for the location of cryotherapy application, indicating no differences between the application over the quadriceps and the knee joint. In conclusion, cryotherapy impairs knee joint position sense in normal knees. This deleterious effect is similar when cryotherapy is applied over the quadriceps or the knee joint. Georg Thieme Verlag KG Stuttgart.New York.

  1. MULTIPLE NONSPECIFIC SITES OF JOINT PAIN OUTSIDE THE KNEES DEVELOP IN PERSONS WITH KNEE PAIN

    PubMed Central

    Felson, David T.; Niu, Jingbo; Quinn, Emily K; Neogi, Tuhina; Lewis, Cara; Lewis, Cora E.; Law, Laura Frey; McCulloch, Chuck; Nevitt, Michael; LaValley, Michael

    2017-01-01

    Objective Many persons with knee pain have joint pain outside the knee but despite the impact and high frequency of this pain, its distribution and causes have not been studied. Those studying gait abnormalities have suggested that knee pain causes pain in adjacent joints but pain adaptation strategies are highly individualized. Methods We studied persons age 50-79 years with or at high risk of knee osteoarthritis drawn from two community-based cohorts, the Multicenter Osteoarthritis Study and the Osteoarthritis Initiative and followed for 5-7 years. We excluded those with knee pain at baseline and compared those who developed and did not develop knee pain at the first follow-up examination (the index visit). We examined pain on most days at joint regions outside the knee in examinations after the index visit. Logistic regression analyses examined the risk of joint specific pain adjusted for age, sex, BMI, depression with sensitivity analyses excluding those with widespread pain. Results In the combined cohorts, there were 693 persons with index visit knee pain vs. 2793 without it. 79.6% of those with bilateral and 63.8% of those with unilateral knee pain had pain during follow-up in a joint region outside the knee vs. 49.9% of those without knee pain. An increased risk of pain was present in most extremity joint sites without a predilection for specific sites. Results were unchanged when those with widespread pain were excluded. Conclusions Persons with chronic knee pain are at increased risk of pain in multiple joints in no specific pattern. PMID:27589036

  2. Return to running following knee osteochondral repair using an anti-gravity treadmill: A case report.

    PubMed

    Hambly, Karen; Poomsalood, Somruthai; Mundy, Emma

    2017-07-01

    The purpose of this study was to assess the impact of an anti-gravity treadmill return to running programme on self-efficacy and subjective knee function following knee osteochondral surgery. A 39-year-old otherwise healthy female endurance runner with a left knee femoral cartilage grade 3-4 defect 3 cm 2 . The patient underwent single step arthroscopic microfracture with Bone Marrow Aspirate Concentrate. An AlterG ® anti-gravity treadmill was used to manipulate loading during a graduated phased return to running over 8 weeks. Self-efficacy was evaluated using the Self-Efficacy for Rehabilitation outcomes scale (SER) and the Knee Self-Efficacy Scale (K-SES). Subjective knee function was evaluated using the Knee injury and Osteoarthritis Outcome Score (KOOS) and International Knee Documentation Committee Subjective Knee Form (IKDC). The programme resulted in improvements in SER (57%), K-SES present (89%) and K-SES future (65%) self-efficacy domains. The IKDC score demonstrated a clinically important improvement with an increase from 62.1 in week 1-86.2 in week 8 (39%). Only the KOOS Sport/Rec subscale showed a clinically important improvement from week 1 to week 8. The programme resulted in improved knee and rehabilitation self-efficacy and subjective knee function following osteochondral repair of the knee. This case report illustrates the importance of considering self-efficacy in rehabilitation after knee osteochondral surgery and highlights the potential role for anti-gravity treadmills in enhancing self-efficacy and subjective knee function in preparation for a return to sport. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  3. Relationships Between Varus–Valgus Laxity of the Severely Osteoarthritic Knee and Gait, Instability, Clinical Performance, and Function

    PubMed Central

    Freisinger, Gregory M.; Hutter, Erin E.; Lewis, Jacqueline; Granger, Jeffrey F.; Glassman, Andrew H.; Beal, Matthew D.; Pan, Xueliang; Schmitt, Laura C.; Siston, Robert A.; Chaudhari, Ajit M.W.

    2017-01-01

    Increased varus–valgus laxity has been reported in individuals with knee osteoarthritis (OA) compared to controls. However, the majority of previous investigations may not report truly passive joint laxity, as their tests have been performed on conscious participants who could be guarding against motion with muscle contraction during laxity evaluation. The purpose of this study was to investigate how a measure of passive knee laxity, recorded when the participant is under anesthesia, is related to varus–valgus excursion during gait, clinical measures of performance, perceived instability, and self-reported function in participants with severe knee OA. We assessed passive varus–valgus knee laxity in 29 participants (30 knees) with severe OA, as they underwent total knee arthroplasty (TKA). Participants also completed gait analysis, clinical assessment of performance (6-min walk (6 MW), stair climbing test (SCT), isometric knee strength), and self-reported measures of function (perceived instability, Knee injury, and Osteoarthritis Outcome Score (KOOS) a median of 18 days before the TKA procedure. We observed that greater passive varus–valgus laxity was associated with greater varus–valgus excursion during gait (R2 =0.34, p =0.002). Significant associations were also observed between greater laxity and greater isometric knee extension strength (p =0.014), farther 6 MW distance (p =0.033) and shorter SCT time (p =0.046). No relationship was observed between passive varus–valgus laxity and isometric knee flexion strength, perceived instability, or any KOOS subscale. The conflicting associations between laxity, frontal excursion during gait, and functional performance suggest a complex relationship between laxity and knee cartilage health, clinical performance, and self-reported function that merits further study. PMID:27664972

  4. The Influence of Knee Flexion Angle for Graft Fixation on Rotational Knee Stability During Anterior Cruciate Ligament Reconstruction: A Biomechanical Study.

    PubMed

    Debandi, Aníbal; Maeyama, Akira; Hoshino, Yuichi; Asai, Shigehiro; Goto, Bunsei; Smolinski, Patrick; Fu, Freddie H

    2016-11-01

    To evaluate the effect of knee flexion angle for hamstring graft fixation, full extension (FE), or 30°, on acceleration of the knee motion during pivot-shift testing after either anatomic or nonanatomic anterior cruciate ligament (ACL) reconstruction using triaxial accelerometry. Two types of ACL reconstructions (anatomic and nonanatomic) using 2 different angles of knee flexion during graft fixation (FE and 30°) were performed on 12 fresh-frozen human knees making 4 groups: anatomic-FE, anatomic-30°, nonanatomic-FE, and nonanatomic-30°. Manual pivot-shift testing was performed at ACL-intact, ACL-deficient, and ACL-reconstructed conditions. Three-dimensional acceleration of knee motion was recorded using a triaxial accelerometer. The anatomic-30° group showed the smallest overall magnitude of acceleration among the ACL-reconstructed groups (P = .0039). There were no significant differences among the anatomic-FE group, the nonanatomic-FE group, and the nonantomic-30° group (anatomic-FE vs nonanatomic-FE, P = .1093; anatomic-FE vs nonanatomic-30°, P = .8728; and nonanatomic-FE vs nonanatomic-30°, P = .1093). After ACL transection, acceleration was reduced by ACL reconstruction with the exception of the nonanatomic-FE group that did not show a significant difference when compared with the ACL-deficient (P = .4537). The anatomic ACL reconstruction with the graft fixed at 30° of knee flexion better restored rotational knee stability compared with FE. An ACL graft fixed with the knee at FE in anatomic position did not show a significant difference compared with the nonanatomic ACL reconstructions. Knee flexion angle at the time of graft fixation for ACL reconstruction can be considered to maximize the rotational knee stability. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  5. Evaluation of total knee mechanics using a crouching simulator with a synthetic knee substitute.

    PubMed

    Lowry, Michael; Rosenbaum, Heather; Walker, Peter S

    2016-05-01

    Mechanical evaluation of total knees is frequently required for aspects such as wear, strength, kinematics, contact areas, and force transmission. In order to carry out such tests, we developed a crouching simulator, based on the Oxford-type machine, with novel features including a synthetic knee including ligaments. The instrumentation and data processing methods enabled the determination of contact area locations and interface forces and moments, for a full flexion-extension cycle. To demonstrate the use of the simulator, we carried out a comparison of two different total knee designs, cruciate retaining and substituting. The first part of the study describes the simulator design and the methodology for testing the knees without requiring cadaveric knee specimens. The degrees of freedom of the anatomic hip and ankle joints were reproduced. Flexion-extension was obtained by changing quadriceps length, while variable hamstring forces were applied using springs. The knee joint was represented by three-dimensional printed blocks on to which the total knee components were fixed. Pretensioned elastomeric bands of realistic stiffnesses passed through holes in the block at anatomical locations to represent ligaments. Motion capture of the knees during flexion, together with laser scanning and computer modeling, was used to reconstruct contact areas on the bearing surfaces. A method was also developed for measuring tibial component interface forces and moments as a comparative assessment of fixation. The method involved interposing Tekscan pads at locations on the interface. Overall, the crouching machine and the methodology could be used for many different mechanical measurements of total knee designs, adapted especially for comparative or parametric studies. © IMechE 2016.

  6. Impact of clinical decision rules on clinical care of traumatic injuries to the foot and ankle, knee, cervical spine, and head.

    PubMed

    Perry, Jeffrey J; Stiell, Ian G

    2006-12-01

    Traumatic injuries to the ankle/foot, knee, cervical spine, and head are very commonly seen in emergency and accident departments around the world. There has been much interest in the development of clinical decision rules to help guide the investigations of these patients in a standardised and cost-effective manner. In this article we reviewed the impact of the Ottawa ankle rules, Ottawa knee rules, Canadian C-spine rule and the Canadian CT head rule. The studies conducted have confirmed that the use of well developed clinical decision rules results in less radiography, less time spent in the emergency department and does not decrease patient satisfaction or result in misdiagnosis. Emergency physicians around the world should adopt the use of clinical decision rules for ankle/foot, knee, cervical spine and minor head injuries. With relatively simple implementation strategies, care can be standardized and costs reduced while providing excellent clinical care.

  7. Translation and Validation of the Korean Version of the International Knee Documentation Committee Subjective Knee Form

    PubMed Central

    Kim, Jin Goo; Lee, Joong Yub; Seo, Seung Suk; Choi, Choong Hyeok; Lee, Myung Chul

    2013-01-01

    Purpose To perform a cross-cultural adaptation and to test the measurement properties of the Korean version of International Knee Documentation Committee (K-IKDC) Subjective Knee Form. Materials and Methods According to the guidelines for cross-cultural adaptation, translation and backward translation of the English version of the IKDC Subjective Knee Form were performed. After translation into the Korean version, 150 patients who had knee-related problems were asked to complete the K-IKDC, Lysholm score, and Short Form-36 (SF-36). Of these patients, 126 were retested 2 weeks later to evaluate test-retest reliability, and 104 were recruited 3 months later to evaluate responsiveness. Construct validity was analyzed by investigating the correlation with Lysholm score and SF-36; content validity was also evaluated. Standardized mean response was calculated for evaluating responsiveness. Results The test-retest reliability proved excellent with a high value for the intraclass correlation coefficient (r=0.94). The internal consistency was strong (Cronbach's α=0.91). Good content validity with absence of floor not ceiling effects and good convergent and divergent validity were observed. Moderate responsiveness was shown (standardized mean response=0.689). Conclusions The K-IKDC demonstrated good measurement properties. We suggest that this instrument is an excellent evaluation instrument that can be used for Korean patients with knee-related injuries. PMID:24032098

  8. Provocative mechanical tests of the peripheral nervous system affect the joint torque-angle during passive knee motion.

    PubMed

    Andrade, R J; Freitas, S R; Vaz, J R; Bruno, P M; Pezarat-Correia, P

    2015-06-01

    This study aimed to determine the influence of the head, upper trunk, and foot position on the passive knee extension (PKE) torque-angle response. PKE tests were performed in 10 healthy subjects using an isokinetic dynamometer at 2°/s. Subjects lay in the supine position with their hips flexed to 90°. The knee angle, passive torque, surface electromyography (EMG) of the semitendinosus and quadriceps vastus medialis, and stretch discomfort were recorded in six body positions during PKE. The different maximal active positions of the cervical spine (neutral; flexion; extension), thoracic spine (neutral; flexion), and ankle (neutral; dorsiflexion) were passively combined for the tests. Visual analog scale scores and EMG were unaffected by body segment positioning. An effect of the ankle joint was verified on the peak torque and knee maximum angle when the ankle was in the dorsiflexion position (P < 0.05). Upper trunk positioning had an effect on the knee submaximal torque (P < 0.05), observed as an increase in the knee passive submaximal torque when the cervical and thoracic spines were flexed (P < 0.05). In conclusion, other apparently mechanical unrelated body segments influence torque-angle response since different positions of head, upper trunk, and foot induce dissimilar knee mechanical responses during passive extension. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Smartphone versus knee ligament arthrometer when size does not matter.

    PubMed

    Ferretti, Andrea; Andrea, Ferretti; Valeo, Luigi; Luigi, Valeo; Mazza, Daniele; Daniele, Mazza; Muliere, Luca; Luca, Muliere; Iorio, Paolo; Paolo, Iorio; Giovannetti, Giovanni; Giovanni, Giovannetti; Conteduca, Fabio; Fabio, Conteduca; Iorio, Raffaele; Raffaele, Iorio

    2014-10-01

    The use of available mechanical methods to measure anterior tibial translation (ATT) in anterior cruciate ligament (ACL)-deficient knees are limited by size and costs. This study evaluated the performance of a portable device based on a downloadable electronic smartphone application to measure ATT in ACL-deficient knees. A specific smartphone application (SmartJoint) was developed for this purpose. Two independent observers nonsequentially measured the amount of ATT during execution of a maximum manual Lachman test in 35 patients with an ACL-deficient knee using KT 1000 and SmartJoint on both involved and uninvolved knees. As each examiner performed the test three times on each knee, a total of 840 measurements were collected. Statistical analysis compared intertest, interobserver and intra-observer reliability using the interclass correlation coefficient (ICC). An ICC > 0.75 indicates excellent reproducibility among measurements. Mean amount of ATT on uninvolved knees was 6.1 mm [standard deviation (SD = 2)] with the KT 1000 and 6.4 mm (SD = 2) with SmartJoint. Mean side-to-side difference was 8.1 mm. (SD = 4) with KT 1000 and 8.3 mm (SD = 3) with SmartJoint. Intertest reliability between the two methods yielded an ICC 0.797 [95 % confidence interval (CI) 0.717-0.857] for the uninvolved knee and of 0.987 (CI 0.981-0.991) for the involved knee. Interobserver ICC for SmartJoint and KT 1000 was 0.957 (CI 0.927-0.976) for the uninvolved knee and 0.992 (CI 0.986-0.996) for the involved knee and 0.973 (CI 0.954-0.985) for the uninvolved knee and 0.989 (CI 0.981-0.994) for involved knee, respectively. The performance of SmartJoint is comparable and highly correlated with measurements obtained from KT 1000. SmartJoint may provide a truly portable, noninvasive, accurate, reliable, inexpensive and widely accessible method to characterize ATT in ACL-deficient knee.

  10. Psychosocial factors partially mediate the relationship between mechanical hyperalgesia and self-reported pain.

    PubMed

    Mason, Kayleigh J; O'Neill, Terence W; Lunt, Mark; Jones, Anthony K P; McBeth, John

    2018-01-26

    Amplification of sensory signalling within the nervous system along with psychosocial factors contributes to the variation and severity of knee pain. Quantitative sensory testing (QST) is a non-invasive test battery that assesses sensory perception of thermal, pressure, mechanical and vibration stimuli used in the assessment of pain. Psychosocial factors also have an important role in explaining the occurrence of pain. The aim was to determine whether QST measures were associated with self-reported pain, and whether those associations were mediated by psychosocial factors. Participants with knee pain identified from a population-based cohort completed a tender point count and a reduced QST battery of thermal, mechanical and pressure pain thresholds, temporal summation, mechanical pain sensitivity (MPS), dynamic mechanical allodynia (DMA) and vibration detection threshold performed following the protocol by the German Research Network on Neuropathic Pain. QST assessments were performed at the most painful knee and opposite forearm (if pain-free). Participants were asked to score for their global and knee pain intensities within the past month (range 0-10), and complete questionnaire items investigating anxiety, depression, illness perceptions, pain catastrophising, and physical functioning. QST measures (independent variable) significantly correlated (Spearman's rho) with self-reported pain intensity (dependent variable) were included in structural equation models with psychosocial factors (latent mediators). Seventy-two participants were recruited with 61 participants (36 women; median age 64 years) with complete data included in subsequent analyses. Tender point count was significantly correlated with global pain intensity. DMA at the knee and MPS at the most painful knee and opposite pain-free forearm were significantly correlated with both global pain and knee pain intensities. Psychosocial factors including pain catastrophising sub-scales (rumination and helplessness) and illness perceptions (consequences and concern) were significant partial mediators of the association with global pain intensity when loaded on to a latent mediator for: tender point count [75% total effect; 95% confidence interval (CI) 22%, 100%]; MPS at the knee (49%; 12%, 86%); and DMA at the knee (63%; 5%, 100%). Latent psychosocial factors were also significant partial mediators of the association between pain intensity at the tested knee with MPS at the knee (30%; 2%, 58%), but not for DMA at the knee. Measures of mechanical hyperalgesia at the most painful knee and pain-free opposite forearm were associated with increased knee and global pain indicative of altered central processing. Psychosocial factors were significant partial mediators, highlighting the importance of the central integration of emotional processing in pain perception. Associations between mechanical hyperalgesia at the forearm and knee, psychosocial factors and increased levels of clinical global and knee pain intensity provide evidence of altered central processing as a key mechanism in knee pain, with psychological factors playing a key role in the expression of clinical pain.

  11. Effect of 7-days dry immersion in combination with mechanical stimulation of foot support zones upon resistance to fatigue of knee extensors and flexors

    NASA Astrophysics Data System (ADS)

    Netreba, A. I.; Khusnutdiniva, D. R.; Vinogradova, O. L.; Kozlovskaya, I. B.

    2005-08-01

    The aim of investigation was to reveal the effect of supportlessness in combination with artificial stimulation of foot support zones on fatigue resistance of knee extensors and flexors in static and rhythmic tests. 10 volunteers were exposed to 7 days dry immersion (DI). 4 of them were subjected to mechanical stimulation of foot support zones. 7-day DI did not evoke any changes in fatigue resistance during rhythmic contractions of knee extensors and flexors in both groups. Static test revealed significant decrease of fatigue resistance of both knee flexors and extensors. In the group with stimulation of support zones unfavorable effects of immersion were minimized for knee extensors but not for flexors. Thus support withdrawal is associated with a decrease of fatigue resistance for both knee flexors and extensors only under conditions of static tension. Artificial stimulation of support zones of the foot selectively affects the posture muscles.

  12. Wear Distribution Detection of Knee Joint Prostheses by Means of 3D Optical Scanners

    PubMed Central

    Affatato, Saverio; Valigi, Maria Cristina; Logozzo, Silvia

    2017-01-01

    The objective of this study was to examine total knee polyethylene inserts from in vitro simulation to evaluate and display—using a 3D optical scanner—wear patterns and wear rates of inserts exposed to wear by means of simulators. Various sets of tibial inserts have been reconstructed by using optical scanners. With this in mind, the wear behavior of fixed and mobile bearing polyethylene knee configurations was investigated using a knee wear joint simulator. After the completion of the wear test, the polyethylene menisci were analyzed by an innovative 3D optical scanners in order to evaluate the 3D wear distribution on the prosthesis surface. This study implemented a new procedure for evaluating polyethylene bearings of joint prostheses obtained after in vitro wear tests and the proposed new approach allowed quantification of the contact zone on the geometry of total knee prostheses. The results of the present study showed that mobile TKPs (total knee prosthesis) have lower wear resistance with respect to fixed TKPs. PMID:28772725

  13. Clinical assessment of effusion in knee osteoarthritis—A systematic review

    PubMed Central

    Maricar, Nasimah; Callaghan, Michael J.; Parkes, Matthew J.; Felson, David T.; O׳Neill, Terence W.

    2016-01-01

    Objective The aim of this systematic review was to determine the validity and inter- and intra-observer reliability of the assessment of knee joint effusion in osteoarthritis (OA) of the knee. Methods MEDLINE, Web of Knowledge, CINAHL, EMBASE, and AMED were searched from their inception to February 2015. Articles were included according to a priori defined criteria: samples containing participants with knee OA; prospective evaluation of clinical tests and assessments of knee effusion that included reliability, sensitivity, and specificity of these tests. Results A total of 10 publications were reviewed. Eight of these considered reliability and four on validity of clinical assessments against ultrasound effusion. It was not possible to undertake a meta-analysis of reliability or validity because of differences in study designs and the clinical tests. Intra-observer kappa agreement for visible swelling ranged from 0.37 (suprapatellar) to 1.0 (prepatellar); for bulge sign 0.47 and balloon sign 0.37. Inter-observer kappa agreement for visible swelling ranged from −0.02 (prepatellar) to 0.65 (infrapatellar), the balloon sign −0.11 to 0.82, patellar tap −0.02 to 0.75 and bulge sign kappa −0.04 to 0.14 or reliability coefficient 0.97. Reliability and diagnostic accuracy tended to be better in experienced observers. Very few data looked at performance of individual clinical tests with sensitivity ranging 18.2–85.7% and specificity 35.3–93.3%, both higher with larger effusions. Conclusion The majority of unstandardized clinical tests to assess joint effusion in knee OA had relatively low intra- and inter-observer reliability. There is some evidence experience improved reliability and diagnostic accuracy of tests. Currently there is insufficient evidence to recommend any particular test in clinical practice. PMID:26581486

  14. Clinical assessment of effusion in knee osteoarthritis-A systematic review.

    PubMed

    Maricar, Nasimah; Callaghan, Michael J; Parkes, Matthew J; Felson, David T; O'Neill, Terence W

    2016-04-01

    The aim of this systematic review was to determine the validity and inter- and intra-observer reliability of the assessment of knee joint effusion in osteoarthritis (OA) of the knee. MEDLINE, Web of Knowledge, CINAHL, EMBASE, and AMED were searched from their inception to February 2015. Articles were included according to a priori defined criteria: samples containing participants with knee OA; prospective evaluation of clinical tests and assessments of knee effusion that included reliability, sensitivity, and specificity of these tests. A total of 10 publications were reviewed. Eight of these considered reliability and four on validity of clinical assessments against ultrasound effusion. It was not possible to undertake a meta-analysis of reliability or validity because of differences in study designs and the clinical tests. Intra-observer kappa agreement for visible swelling ranged from 0.37 (suprapatellar) to 1.0 (prepatellar); for bulge sign 0.47 and balloon sign 0.37. Inter-observer kappa agreement for visible swelling ranged from -0.02 (prepatellar) to 0.65 (infrapatellar), the balloon sign -0.11 to 0.82, patellar tap -0.02 to 0.75 and bulge sign kappa -0.04 to 0.14 or reliability coefficient 0.97. Reliability and diagnostic accuracy tended to be better in experienced observers. Very few data looked at performance of individual clinical tests with sensitivity ranging 18.2-85.7% and specificity 35.3-93.3%, both higher with larger effusions. The majority of unstandardized clinical tests to assess joint effusion in knee OA had relatively low intra- and inter-observer reliability. There is some evidence experience improved reliability and diagnostic accuracy of tests. Currently there is insufficient evidence to recommend any particular test in clinical practice. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  15. The effect of changing condition of walking speed on the knee angle of rats with osteoarthritis.

    PubMed

    Nam, Chan-Woo; Kim, Kyoung; Na, Sang-Su

    2017-08-01

    [Purpose] The purpose of this study was to investigate the positive effect of exercise on knee osteoarthritis in rats with osteoarthritis induced by applying effective walking speed when changing speed conditions during walking. [Subjects and Methods] The rats used in this study were male Sprague-Dawley rats weighing 300 g and 7 weeks old, and 20 rats were used. The Osteoarthritis (OA) rats model was induced by MIA (monoiodoacetate). The rats was randomly divided into experimental group (MIA injection group) and control group (normal cell line injection group). Treadmill exercise was provided two groups for 2 weeks, 4 days per week. The knee joint angle of the stance was divided into pre-test and post-test, and each group was subjected to paired sample test. Independent sample t-test was conducted to examine the difference between experimental group and control group. [Results] There were statistically significant changes in the control and experimental groups. The knee angle was changed from 99.70 ± 2.40 to 85.60 ± 2.67 in the control group. The knee angle was changed from 100.96 ± 1.36 to 87.71 ± 1.57 in the experimental group. [Conclusion] In conclusion, the angle of the knee gradually decreases. It is considered a characteristic of progressive osteoarthritis. The change of knee angle was less in the experimental group than in the control group. This means that the stiffness of the joints during the walking exercise was less progressed in the experimental group than in the control group.

  16. The effect of changing condition of walking speed on the knee angle of rats with osteoarthritis

    PubMed Central

    Nam, Chan-Woo; Kim, Kyoung; Na, Sang-Su

    2017-01-01

    [Purpose] The purpose of this study was to investigate the positive effect of exercise on knee osteoarthritis in rats with osteoarthritis induced by applying effective walking speed when changing speed conditions during walking. [Subjects and Methods] The rats used in this study were male Sprague-Dawley rats weighing 300 g and 7 weeks old, and 20 rats were used. The Osteoarthritis (OA) rats model was induced by MIA (monoiodoacetate). The rats was randomly divided into experimental group (MIA injection group) and control group (normal cell line injection group). Treadmill exercise was provided two groups for 2 weeks, 4 days per week. The knee joint angle of the stance was divided into pre-test and post-test, and each group was subjected to paired sample test. Independent sample t-test was conducted to examine the difference between experimental group and control group. [Results] There were statistically significant changes in the control and experimental groups. The knee angle was changed from 99.70 ± 2.40 to 85.60 ± 2.67 in the control group. The knee angle was changed from 100.96 ± 1.36 to 87.71 ± 1.57 in the experimental group. [Conclusion] In conclusion, the angle of the knee gradually decreases. It is considered a characteristic of progressive osteoarthritis. The change of knee angle was less in the experimental group than in the control group. This means that the stiffness of the joints during the walking exercise was less progressed in the experimental group than in the control group. PMID:28878468

  17. Wear Behavior of an Unstable Knee: Stabilization via Implant Design?

    PubMed Central

    Reinders, Jörn; Kretzer, Jan Philippe

    2014-01-01

    Background. Wear-related failures and instabilities are frequent failure mechanisms of total knee replacements. High-conforming designs may provide additional stability for the joint. This study analyzes the effects of a ligamentous insufficiency on the stability and the wear behavior of a high-conforming knee design. Methods. Two simulator wear tests were performed on a high-conforming total knee replacement design. In the first, a ligamentous-stable knee replacement with a sacrificed anterior cruciate ligament was simulated. In the second, a ligamentous-unstable knee with additionally insufficient posterior cruciate ligament and medial collateral ligament was simulated. Wear was determined gravimetrically and wear particles were analyzed. Implant kinematics was recorded during simulation. Results. Significantly higher wear rates (P ≤ 0.001) were observed for the unstable knee (14.58 ± 0.56 mg/106 cycles) compared to the stable knee (7.97 ± 0.87 mg/106 cycles). A higher number of wear particles with only small differences in wear particle characteristics were observed. Under unstable knee conditions, kinematics increased significantly for translations and rotations (P ≤ 0.01). This increase was mainly attributed to higher tibial posterior translation and internal rotations. Conclusion. Higher kinematics under unstable test conditions is a result of insufficient stabilization via implant design. Due to the higher kinematics, increased wear was observed in this study. PMID:25276820

  18. Reducing gender disparities in post-total knee arthroplasty expectations through a decision aid.

    PubMed

    Volkmann, Elizabeth R; FitzGerald, John D

    2015-02-07

    Gender disparities in total knee arthroplasty utilization may be due to differences in perceptions and expectations about total knee arthroplasty outcomes. This study evaluates the impact of a decision aid on perceptions about total knee arthroplasty and decision-making parameters among patients with knee osteoarthritis. Patients with moderate to severe knee osteoarthritis viewed a video about knee osteoarthritis treatments options, including total knee arthroplasty, and received a personalized arthritis report. An adapted version of the Western Ontario and McMaster Universities Osteoarthritis Index was used to assess pain and physical function expectations following total knee arthroplasty before/after the intervention. These scores were compared to an age- and gender-adjusted means for a cohort of patients who had undergone total knee arthroplasty. Decision readiness and conflict were also measured. At baseline, both men and women had poorer expectations about post-operative pain and physical outcomes compared with observed outcomes of the comparator group. Following the intervention, women's mean age-adjusted expectations about post- total knee arthroplasty pain outcomes improved (Pre: 27.0; Post: 21.8 [p =0.08; 95% CI -0.7, 11.0]) and were closer to observed post-TKA outcomes; whereas men did not have a significant change in their pain expectations (Pre: 21.3; Post: 19.6 [p = 0.6; 95% CI -5.8, 9.4]). Women also demonstrated a significant improvement in decision readiness; whereas men did not. Both genders had less decision conflict after the intervention. Both women and men with osteoarthritis had poor estimates of total knee arthroplasty outcomes. Women responded to the intervention with more accurate total knee arthroplasty outcome expectations and greater decision readiness. Improving patient knowledge of total knee arthroplasty through a decision aid may improve medical decision-making and reduce gender disparities in total knee arthroplasty utilization.

  19. No difference between mechanical perturbation training with compliant surface and manual perturbation training on knee functional performance after ACL rupture.

    PubMed

    Nawasreh, Zakariya; Logerstedt, David; Failla, Mathew; Snyder-Mackler, Lynn

    2017-10-27

    Manual perturbation training improves dynamic knee stability and functional performance after anterior cruciate ligament rupture (ACL-rupture). However, it is limited to static standing position and does not allow time-specific perturbations at different phase of functional activities. The purpose of this study was to investigate whether administering mechanical perturbation training including compliant surface provides effects similar to manual perturbation training on knee functional measures after an acute ACL-rupture. Sixteen level I/II athletes with ACL-ruptures participated in this preliminary study. Eight patients received mechanical (Mechanical) and eight subjects received manual perturbation training (Manual). All patients completed a functional testing (isometric quadriceps strength, single-legged hop tests) and patient-reported measures (Knee Outcome Survey-Activities of Daily Living Scale (KOS-ADLS), Global Rating Score (GRS), International Knee Documentation Committee 2000 (IKDC 2000) at pre- and post-training. 2 × 2 ANOVA was used for data analysis. No significant group-by-time interactions were found for all measures (p > 0.18). Main effects of time were found for single hop (Pre-testing: 85.14% ± 21.07; Post-testing: 92.49% ± 17.55), triple hop (Pre-testing: 84.64% ± 14.17; Post-testing: 96.64% ± 11.14), KOS-ADLS (Pre-testing: 81.13% ± 11.12; Post-testing: 88.63% ± 12.63), GRS (Pre-testing: 68.63% ± 15.73; Post-testing: 78.81% ± 13.85), and IKDC 2000 (Pre-testing: 66.66% ± 9.85; Post-testing: 76.05% ± 14.62) (p < 0.032). Administering mechanical perturbation training using compliant surfaces induce effects similar to manual perturbation training on knee functional performance after acute ACL-rupture. The clinical significance is both modes of training improve patients' functional-performance and limb-to-limb movement symmetry, and enhancing the patients' self-reported of knee functional measures after ACL rupture. Mechanical perturbation that provides a compliant surface might be utilized as part of the ACL rehabilitation training. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  20. Reliability of physical examination tests for the diagnosis of knee disorders: Evidence from a systematic review.

    PubMed

    Décary, Simon; Ouellet, Philippe; Vendittoli, Pascal-André; Desmeules, François

    2016-12-01

    Clinicians often rely on physical examination tests to guide them in the diagnostic process of knee disorders. However, reliability of these tests is often overlooked and may influence the consistency of results and overall diagnostic validity. Therefore, the objective of this study was to systematically review evidence on the reliability of physical examination tests for the diagnosis of knee disorders. A structured literature search was conducted in databases up to January 2016. Included studies needed to report reliability measures of at least one physical test for any knee disorder. Methodological quality was evaluated using the QAREL checklist. A qualitative synthesis of the evidence was performed. Thirty-three studies were included with a mean QAREL score of 5.5 ± 0.5. Based on low to moderate quality evidence, the Thessaly test for meniscal injuries reached moderate inter-rater reliability (k = 0.54). Based on moderate to excellent quality evidence, the Lachman for anterior cruciate ligament injuries reached moderate to excellent inter-rater reliability (k = 0.42 to 0.81). Based on low to moderate quality evidence, the Tibiofemoral Crepitus, Joint Line and Patellofemoral Pain/Tenderness, Bony Enlargement and Joint Pain on Movement tests for knee osteoarthritis reached fair to excellent inter-rater reliability (k = 0.29 to 0.93). Based on low to moderate quality evidence, the Lateral Glide, Lateral Tilt, Lateral Pull and Quality of Movement tests for patellofemoral pain reached moderate to good inter-rater reliability (k = 0.49 to 0.73). Many physical tests appear to reach good inter-rater reliability, but this is based on low-quality and conflicting evidence. High-quality research is required to evaluate the reliability of knee physical examination tests. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Stiff Landings Are Associated With Increased ACL Injury Risk in Young Female Basketball and Floorball Players.

    PubMed

    Leppänen, Mari; Pasanen, Kati; Kujala, Urho M; Vasankari, Tommi; Kannus, Pekka; Äyrämö, Sami; Krosshaug, Tron; Bahr, Roald; Avela, Janne; Perttunen, Jarmo; Parkkari, Jari

    2017-02-01

    Few prospective studies have investigated the biomechanical risk factors of anterior cruciate ligament (ACL) injury. To investigate the relationship between biomechanical characteristics of vertical drop jump (VDJ) performance and the risk of ACL injury in young female basketball and floorball players. Cohort study; Level of evidence, 3. At baseline, a total of 171 female basketball and floorball players (age range, 12-21 years) participated in a VDJ test using 3-dimensional motion analysis. The following biomechanical variables were analyzed: (1) knee valgus angle at initial contact (IC), (2) peak knee abduction moment, (3) knee flexion angle at IC, (4) peak knee flexion angle, (5) peak vertical ground-reaction force (vGRF), and (6) medial knee displacement. All new ACL injuries, as well as match and training exposure, were then recorded for 1 to 3 years. Cox regression models were used to calculate hazard ratios (HRs) and 95% CIs. Fifteen new ACL injuries occurred during the study period (0.2 injuries/1000 player-hours). Of the 6 factors considered, lower peak knee flexion angle (HR for each 10° increase in knee flexion angle, 0.55; 95% CI, 0.34-0.88) and higher peak vGRF (HR for each 100-N increase in vGRF, 1.26; 95% CI, 1.09-1.45) were the only factors associated with increased risk of ACL injury. A receiver operating characteristic (ROC) curve analysis showed an area under the curve of 0.6 for peak knee flexion and 0.7 for vGRF, indicating a failed-to-fair combined sensitivity and specificity of the test. Stiff landings, with less knee flexion and greater vGRF, in a VDJ test were associated with increased risk of ACL injury among young female basketball and floorball players. However, although 2 factors (decreased peak knee flexion and increased vGRF) had significant associations with ACL injury risk, the ROC curve analyses revealed that these variables cannot be used for screening of athletes.

  2. Comparison of Bioabsorbable Interference Screws Composed of Poly-l-lactic Acid and Hydroxyapatite (PLLA-HA) to WasherLoc Tibial Fixation in Patients After Anterior Cruciate Ligament Reconstruction of the Knee Joint.

    PubMed

    Patkowski, Mateusz; Królikowska, Aleksandra; Reichert, Paweł

    2016-01-01

    The reconstruction of the anterior cruciate ligament (ACL) of the knee joint is a standard in ACL complete rupture treatment in athletes. One of the weakest points of this procedure is tibial fixation of grafts. The aim was, firstly, to evaluate patients 3-4 years after primary ACL reconstruction with the use of autologous ipsilateral STGR grafts and with tibial fixation using a bioabsorbable interference screw composed of PLLA-HA or WasherLoc, comparing the postoperative result to the preoperative condition and, secondly, to compare the results between the two groups of patients with different tibial fixation. Group I consisted of 20 patients with a bioabsorbable interference screw composed of PLLA-HA tibial fixation. In Group II, there were 22 patients after ACL reconstruction with the use of WasherLoc tibial fixation. The Lachman test, pivot-shift test, Lysholm Knee Scoring Scale and 2000 International Knee Documentation Committee (2000 IKDC) Subjective Knee Evaluation Form were used to evaluate the results. The intra-group comparison of the results of the 2000 IKDC Subjective Knee Evaluation Form and Lysholm Knee Scoring Scale obtained in the groups studied showed statistically significant differences between the evaluation performed preoperatively and postoperatively. The inter-group comparison of the results of the 2000 IKDC Subjective Knee Evaluation Form and Lysholm Knee Scoring Scale obtained postoperatively showed no statistically significant differences between the two groups. An evaluation 3-4 years after ACL reconstruction with the use of autologous ipsilateral STGR grafts demonstrated significant progress from the preoperative condition to the postoperative result in patients with tibial fixation using a bioabsorbable interference screw composed of PLLA-HA as well as in patients with WasherLoc tibial fixation. There were no differences found between the two groups of patients after ACL reconstruction in terms of manual stability testing or a subjective assessment of knee joint outcomes.

  3. Oxford Knee Score: cross-cultural adaptation and validation of the Turkish version in patients with osteoarthritis of the knee.

    PubMed

    Tuğay, Baki Umut; Tuğay, Nazan; Güney, Hande; Kınıklı, Gizem İrem; Yüksel, İnci; Atilla, Bülent

    2016-01-01

    The Oxford Knee Score (OKS) is a valid, short, self-administered, and site- specific outcome measure specifically developed for patients with knee arthroplasty. This study aimed to cross-culturally adapt and validate the OKS to be used in Turkish-speaking patients with osteoarthritis of the knee. The OKS was translated and culturally adapted according to the guidelines in the literature. Ninety-one patients (mean age: 55.89±7.85 years) with knee osteoarthritis participated in the study. Patients completed the Turkish version of the Oxford Knee Score (OKS-TR), Short-Form 36 Health Survey (SF-36), and Western Ontario and McMaster Universities Index (WOMAC) questionnaires. Internal consistency was tested using Cronbach's α coefficient. Patients completed the OKS-TR questionnaire twice in 7 days to determine the reproducibility. Correlation between the total results of both tests was determined by Spearman's correlation coefficient and intraclass correlation coefficients (ICC). Validity was assessed by calculating Spearman's correlation coefficient between the OKS, WOMAC, and SF-36 scores. Floor and ceiling effects were analyzed. Internal consistency was high (Cronbach's α: 0.90). The reproducibility tested by 2 different methods showed no significant difference (p>0.05). The construct validity analyses showed a significant correlation between the OKS and the other scores (p<0.05). There was no floor or ceiling effect in total OKS score. The OKS-TR is a reliable and valid measure for the self-assessment of pain and function in Turkish-speaking patients with osteoarthritis of the knee.

  4. Chronic Changes in the Articular Cartilage and Meniscus Following Traumatic Impact to the Lapine Knee

    PubMed Central

    Fischenich, Kristine M.; Button, Keith D.; Coatney, Garrett A.; Fajardo, Ryan S.; Leikert, Kevin M.; Haut, Roger C.; Haut Donahue, Tammy L.

    2014-01-01

    The objective of this study was to induce anterior cruciate ligament (ACL) and meniscal damage, via a single tibiofemoral compressive impact, in order to document articular cartilage and meniscal changes post impact. Tibiofemoral joints of Flemish Giant rabbits were subjected to a single blunt impact that ruptured the ACL and produced acute meniscal damage. Animals were allowed unrestricted cage activity for 12 weeks before euthanasia. India ink analysis of the articular cartilage revealed higher degrees of surface damage on the impacted tibias (p=0.018) and femurs (p<0.0001) compared to controls. Chronic meniscal damage was most prevalent in the medial central and medial posterior regions. Mechanical tests revealed an overall 19.4% increase in tibial plateau cartilage thickness (p=0.026), 34.8% increase in tibial plateau permeability (p=0.054), 40.8% increase in femoral condyle permeability (p=0.029), and 20.1% decrease in femoral condyle matrix modulus (p=0.012) in impacted joints compared to controls. Both the instantaneous and equilibrium moduli of the lateral and medial menisci were decreased compared to control (p<0.02). Histological analyses revealed significantly increased presence of fissures in the medial femur (p = 0.036). In both the meniscus and cartilage there was a significant decrease in GAG coverage for the impacted limbs. Based on these results it is clear that an unattended combined meniscal and ACL injury results in significant changes to the soft tissues in this experimental joint 12 weeks post injury. Such changes are consistent with a clinical description of mid to late stage PTOA of the knee. PMID:25523754

  5. Anatomy and physical examination of the knee menisci: a narrative review of the orthopedic literature.

    PubMed

    Chivers, Michael D; Howitt, Scott D

    2009-12-01

    The objective of this study was to review the physical examination tests available to a practitioner in order to arrive at a clinical diagnosis or suspicion of a meniscal lesion. The menisci transmit weight bearing forces and increase stability of the knee. The menisci also facilitate nutrition, provide lubrication and shock absorption for the articular cartilage and promote knee proprioception. The combinations of torsional and axial loading appear to be the cause of most meniscal injuries. Diagnosis of acute knee injuries has long been a topic for discussion throughout the orthopedic literature. Many clinical tests and diagnostic studies have been developed to increase the clinician's ability to accurately diagnose these types of disorders of the knee. The accuracy of all diagnostic tests is thought to be dependant upon the skill of the examiner, and the severity and location of the injury. The multitude of tests described to assess meniscal lesions suggests that none are consistently reliable. However, recent research has focused on a composite score to accurately predict meniscus lesions. The combination of a comprehensive history, multiple physical tests and diagnostic imaging for confirmation is typical for a clinical meniscal lesion diagnosis while the gold standard remains the arthroscopic procedure itself.

  6. Intertester and intratester reliability of a movement control test battery for patients with knee osteoarthritis and controls

    PubMed Central

    Kaukinen, P.T.; Arokoski, J.P.; Huber, E.O.; Luomajoki, H.A.

    2017-01-01

    Objectives: To develop a test battery of movement control (MC) tests and assess its intertester and intratester reliability. Methods: 29 subjects with knee OA with mean age of 64.7 (SD 8.7) years and 12 controls without either knee pain or previous diagnosis of OA (mean age 36.6 (SD 16.2) years) were included. Two experienced physiotherapists rated the filmed test performance of six MC tests blinded to the patients and to each other on 3-point scale as correct, incorrect or failed. Weighted kappa coefficient (wK) with 95% confidence interval (95%CI) and the percentage of agreement were calculated for each test. Results: One-leg stance, one-leg squat 30 degrees and step down tests showed moderate to excellent inter- and intratester reliability with wK ranging between 0.43-0.85 for intertester and 0.51-0.80 for intratester reliability. The reliability of the 90 degrees squat test, small squat and step up tests was poor (wK ranging between 0.09-0.50). Conclusions: One-leg stance test, one-leg squat 30 degrees and step down test are reliable in the subjects with knee OA and controls. Further studies are needed to evaluate the discriminative validity of the reliable tests. PMID:28860422

  7. [Effects of posterior tibial slope on non-contact anterior cruciate ligament rupture and stability of anterior cruciate ligament rupture knee].

    PubMed

    Yue, De-bo; E, Sen; Wang, Bai-liang; Wang, Wei-guo; Guo, Wan-shou; Zhang, Qi-dong

    2013-05-07

    To retrospectively explore the correlation between anterior cruciate ligament (ACL)-ruptured knees, stability of ACL-rupture knee and posterior tibial slope (PTS). From January 2008 to October 2012, 150 knees with ACL rupture underwent arthroscopic surgery for ACL reconstruction. A control group was established for subjects undergoing arthroscopic surgery without ACL rupture during the same period. PTS was measured on a digitalized lateral radiograph. Lachman and mechanized pivot shift tests were performed for assessing the stability of knee. There was significant difference (P = 0.007) in PTS angle between the patients with ACL rupture (9.5 ± 2.2 degrees) and the control group (6.6 ± 1.8 degrees). Only among females, increased slope of tibial plateau had effect on the Lachman test. There was a higher positive rate of pivot shift test in patients of increased posterior slope in the ACL rupture group. Increased posterior tibial slope (>6.6) appears to contribute to non-contact ACL injuries in females. And the changes of tibial slope have no effect upon the Lachman test. However, large changes in tibial slope affect pivot shift.

  8. Cross-cultural adaptation, reliability and validity of the Turkish version of the Hospital for Special Surgery (HSS) Knee Score.

    PubMed

    Narin, Selnur; Unver, Bayram; Bakırhan, Serkan; Bozan, Ozgür; Karatosun, Vasfi

    2014-01-01

    The purpose of this study was to adapt the English version of the Hospital for Special Surgery (HSS) knee score for use in a Turkish population and to evaluate its validity, reliability and cultural adaptation. Standard forward-back translation of the HSS knee score was performed and the Turkish version was applied in 73 patients. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Mini-Mental State Examination and sit-to-stand test were also performed and analyzed. Internal consistency reliability was tested using Cronbach's alpha. The intraclass correlation coefficient (ICC) was used to calculate the test-retest reliability at one-week intervals. Validity was assessed by calculating the Pearson correlation between the HSS, WOMAC and sit-to-stand test scores. The ICC ranged from 0.98 to 0.99 with high internal consistency (Cronbach's alpha: 0.87). The WOMAC score correlated with total HSS score (r: -0.80, p<0.001) and sit-to-stand score (r: 0.12, p: 0.312). The Turkish version of the HSS knee score is reliable and valid in evaluating the total knee arthroplasty in Turkish patients.

  9. A method for performance comparison of polycentric knees and its application to the design of a knee for developing countries.

    PubMed

    Anand, T S; Sujatha, S

    2017-08-01

    Polycentric knees for transfemoral prostheses have a variety of geometries, but a survey of literature shows that there are few ways of comparing their performance. Our objective was to present a method for performance comparison of polycentric knee geometries and design a new geometry. In this work, we define parameters to compare various commercially available prosthetic knees in terms of their stability, toe clearance, maximum flexion, and so on and optimize the parameters to obtain a new knee design. We use the defined parameters and optimization to design a new knee geometry that provides the greater stability and toe clearance necessary to navigate uneven terrain which is typically encountered in developing countries. Several commercial knees were compared based on the defined parameters to determine their suitability for uneven terrain. A new knee was designed based on optimization of these parameters. Preliminary user testing indicates that the new knee is very stable and easy to use. The methodology can be used for better knee selection and design of more customized knee geometries. Clinical relevance The method provides a tool to aid in the selection and design of polycentric knees for transfemoral prostheses.

  10. The acute effect of the tongue position in the mouth on knee isokinetic test performance: a highly surprising pilot study

    PubMed Central

    di Vico, Rosa; Ardigò, Luca Paolo; Salernitano, Gianluca; Chamari, Karim; Padulo, Johnny

    2013-01-01

    Summary The tongue involvement within the isokinetic knee extension/flexion exercises has been investigated. Eighteen participants randomly underwent isokinetic testing at 90 and 180°/s with three different tongue positions: middle position (MID, thrusting on the lingual surface of incisive teeth), lying on the lower arch of the mouth (LOW) and extended up to the palatine spot (UP). Statistical analysis of the data revealed an about 30% significant increase of knee flexion peak torque in UP with respect to MID at both angular speeds. Such a difference could have had a confounding effect on results from numerous past studies using isokinetic knee flexion testing. This study alerts future researchers about standardization of tongue position and warrants further investigations on the explicative processes of this phenomenon. PMID:24596696

  11. Timeframe for return to driving for patients with minimally invasive knee arthroplasty is associated with knee performance on functional tests

    PubMed Central

    2014-01-01

    Background This study hopes to establish the timeframe for a safe return to driving under different speed conditions for patients after minimally invasive total knee arthroplasty and further explores how well various kinds of functional tests on knee performance can predict the patients’ braking ability. Methods 14 patients with right knee osteoarthritis were included in the present study and instructed to perform three simulated driving tasks at preoperative, 2 weeks postoperative and 4 weeks postoperative. Results The results showed that the total braking time at 4 week postoperative has attained the preoperative level at the driving speed 50 and 70 km/hr but not at the driving speed 90 km/hr. It had significantly improving in knee reaction time and maximum isometric force at 4 weeks postoperative. Besides, there was a moderate to high correlation between the scores of the step counts and the total braking time. Conclusions Summary, it is recommended that driving may be resumed 4 weeks after a right knee replacement but had to drive at low or moderate speed and the best predictor of safety driving is step counts. PMID:24913312

  12. Anatomic double-bundle anterior cruciate ligament reconstruction restores patellofemoral contact areas and pressures more closely than nonanatomic single-bundle reconstruction.

    PubMed

    Tajima, Goro; Iriuchishima, Takanori; Ingham, Sheila J M; Shen, Wei; van Houten, Albert H; Aerts, Maarten M; Shimamura, Tadashi; Smolinski, Patrick; Fu, Freddie H

    2010-10-01

    To investigate the effects of anterior cruciate ligament (ACL) deficiency and nonanatomic single-bundle (SB) and anatomic double-bundle (DB) ACL reconstruction on the contact characteristics of the patellofemoral (PF) joint. By use of a materials testing system, 7 fresh-frozen human cadaveric knees were tested. The following states were tested: ACL-intact knee, nonanatomic SB ACL reconstruction, anatomic DB ACL reconstruction, and ACL-deficient knee. Hamstring autografts were used. PF contact pressures and areas were measured with pressure-sensitive film at 30°, 60°, and 90° of knee flexion with a constant 100-N load on the quadriceps tendon. The total contact area of ACL-deficient and nonanatomic SB ACL-reconstructed knees (123.8 ± 63.9 and 149.6 ± 79.3 mm(2), respectively) significantly decreased when compared with those of the intact knee (206.1 ± 83.6 mm(2)) at 30° of knee flexion. The lateral-facet peak pressure of ACL-deficient and nonanatomic SB ACL-reconstructed knees (1.12 ± 0.52 and 1.22 ± 0.54 MPa, respectively) significantly decreased when compared with those of the intact knee (0.68 ± 0.38 MPa) at 90° of knee flexion. Anatomic DB ACL reconstruction restored the contact pressures and areas to values similar to those of the intact knee (no significant difference). ACL deficiency resulted in a significant decrease in the total and medial PF contact areas and in an increase in the lateral PF contact pressure. Anatomic DB ACL reconstruction more closely restored normal PF contact area and pressure than did nonanatomic SB ACL reconstruction. Our findings suggest that the changes in the PF contact area and pressures in ACL deficiency and after nonanatomic SB ACL reconstruction may be one of the causes of PF osteoarthritis or other related PF problems found at long-term follow-up. Anatomic DB ACL reconstruction may reduce the incidence of PF problems by closely restoring the contact area and pressure. Copyright © 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  13. Valgus-varus motion of the knee in normal level walking and stair climbing.

    PubMed

    Yu, B; Stuart, M J; Kienbacher, T; Growney, E S; An, K-N

    1997-07-01

    OBJECTIVE: The knee valgus-varus moment and the knee angles were compared between normal level walking and stair climbing. DESIGN: Ten healthy subjects were tested for ascent, descent, and level walking. BACKGROUND: An understanding of the normal valgus-varus motion of the knee during stair climbing is needed to apply biomechanical analysis of stair climbing as a evaluation tool for knee osteoarthritis patients. METHODS: A motion analysis system, three force plates, and a flight of stairs were used to collect kinematic and kinetic data. The knee angles and moments were calculated from the collected kinematic and kinetic data. RESULTS: The knee varus angle for the maximum knee valgus moments in stair climbing was significantly greater than that in level walking. The knee valgus moment was significantly correlated to ground reaction forces and knee valgus-varus angle during stair climbing and level walking. CONCLUSIONS: There is a coupling between the knee valgus-varus motion and flexion-extension motion. Ground reaction forces are the major contributors to the within-subject variation in the knee valgus-varus moment during stair climbing and level walking. The knee valgus-varus angle is a major contributor to the between-subject variation in the knee valgus moment during stair climbing and level walking.

  14. Biomechanical comparison of two surgical techniques for press-fit reconstruction of the posterolateral complex of the knee.

    PubMed

    Panzica, Martin; Janzik, Janne; Bobrowitsch, Evgenij; Krettek, Christian; Hawi, Nael; Hurschler, Christof; Jagodzinski, Michael

    2015-11-01

    To date, various surgical techniques to treat posterolateral knee instability have been described. Recent studies recommended an anatomical and isometric reconstruction of the posterolateral corner addressing the key structures, such as lateral collateral ligament (LCL), popliteus tendon (POP) and popliteofibular ligament (PFL). Two clinical established autologous respective local reconstruction methods of the posterolateral complex were tested for knot-bone cylinder press-fit fixation to assess efficacy of each reconstruction technique in comparison to the intact knee. The knot-bone cylinder press-fit fixation for both anatomic and isometric reconstruction techniques of the posterolateral complex shows equal biomechanical stability as the intact posterolateral knee structures. This was a controlled laboratory study. Two surgical techniques (Larson: fibula-based semitendinosus autograft for LCL and PFL reconstruction/Kawano: biceps femoris and iliotibial tract autograft for LCL, PFL and POP reconstruction) with press-fit fixation were used for restoration of posterolateral knee stability. Seven cadaveric knees (66 ± 3.4 years) were tested under three conditions: intact knee, sectioned state and reconstructed knee for each surgical technique. Biomechanical stress tests were performed for every state at 30° and 90° knee flexion for anterior-posterior translation (60 N), internal-external and varus-valgus rotation (5 Nm) at 0°, 30° and 90° using a kinemator (Kuka robot). At 30° and 90° knee flexion, no significant differences between the four knee states were registered for anterior-posterior translation loading. Internal-external and varus-valgus rotational loading showed significantly higher instability for the sectioned state than for the intact or reconstructed posterolateral structures (p < 0.05). There were no significant differences between the intact and reconstructed knee states for internal-external rotation, varus-valgus rotation and anterior-posterior translation at any flexion angles (p > 0.05). Comparing both reconstruction techniques, significant higher varus-/valgus stability was registered for the fibula-based Larson technique at 90° knee flexion (p < 0.05). Both PLC reconstructions showed equal biomechanical stability as the intact posterolateral knee structures when using knot-bone cylinder press-fit fixation. We registered restoration of the rotational and varus-valgus stability with both surgical techniques. The anterior-posterior translational stability was not influenced significantly. The Larson technique showed significant higher varus/valgus stability in 90° flexion. The latter is easier to perform and takes half the preparation time, but needs grafting of the semitendinosus tendon. The Kawano reconstruction technique is an interesting alternative in cases of missing autografts.

  15. Translation and validation of the Dutch new Knee Society Scoring System ©.

    PubMed

    Van Der Straeten, Catherine; Witvrouw, Erik; Willems, Tine; Bellemans, Johan; Victor, Jan

    2013-11-01

    A new version of The Knee Society Knee Scoring System(©) (KSS) has recently been developed. Before this scale can be used in non-English-speaking populations, it has to be translated and validated for a particular population. We evaluated the construct and content validity, the test-retest reliability, and the internal consistency of the Dutch version of the New Knee Society KSS. A Dutch translation was performed using a forward-backward translation protocol. We tested the construct validity of the Dutch New KSS by comparing it with the Dutch versions of the WOMAC, Knee Injury and Osteoarthritis Outcome Score (KOOS), and SF-12 scores in 137 patients undergoing total knee arthroplasty (TKA). Content validity was assessed by comparing pre- and postoperative scores and by checking floor and ceiling effects. To evaluate test-retest reliability and consistency, 47 patients completed the questionnaire a second time with a mean of 8 days interval (range, 2-20 days) between tests. Construct validity was demonstrated because the Dutch New KSS correlated well with the Dutch WOMAC (r = -0.751; p < 0.001), Dutch KOOS (r = -0.723; p < 0.001), and Dutch SF-12 (r = 0.569; p < 0.001). There was a significant difference between pre- and postoperative scores (p < 0.001) in line with the other scores. Test-retest reliability proved excellent with an intraclass correlation coefficient between 0.73 and 0.92 depending on the domain tested. Consistency as indicated by Cronbach's alpha ranging from 0.84 to 0.96 was good to excellent. As demonstrated by the validation procedure, the Dutch New KSS is an excellent instrument to evaluate TKA outcome in Dutch-speaking patients.

  16. Possibilities and limitations of novel in-vitro knee simulator.

    PubMed

    Verstraete, Matthias A; Victor, Jan

    2015-09-18

    The ex-vivo evaluation of knee kinematics remains vital to understand the impact of surgical treatments such as total knee arthroplasty (TKA). To that extent, knee simulators have been developed. However, these simulators have mainly focused on the simulation of a squatting motion. The relevance of this motion pattern for patients' activities of daily living is however questionable as squatting is difficult for elderly patients. Walking, stairs and cycling are more relevant motion patterns. This paper presents the design and control of a simulator that allows to independently control the applied kinematic and kinetic boundary conditions to simulate these daily life activities. Thereby, the knee is left with five degrees of freedom; only the knee flexion is actively controlled. From a kinetic point of view, the quadriceps and hamstring muscles are loaded. Optionally, a varus/valgus moment can be applied, facilitating a dynamic evaluation of the knee's stability. The simulator is based on three control loops, whose synchronization appears satisfactory. The input for these control loops can be determined from either musculoskeletal simulations or in accordance to literature data for traditional knee simulators. This opens the door towards an improved understanding of the knee biomechanics and comparison between different applied motion and force patterns. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Effects of lower extremity injuries on aerobic exercise capacity, anaerobic power, and knee isokinetic muscular function in high school soccer players.

    PubMed

    Ko, Kwang-Jun; Ha, Gi-Chul; Kim, Dong-Woo; Kang, Seol-Jung

    2017-10-01

    [Purpose] The study investigated the effects of lower extremity injuries on aerobic exercise capacity, anaerobic power, and knee isokinetic muscular function in high school soccer players. [Subjects and Methods] The study assessed U High School soccer players (n=40) in S area, South Korea, divided into 2 groups: a lower extremity injury group (n=16) comprising those with knee and ankle injuries and a control group (n=24) without injury. Aerobic exercise capacity, anaerobic power, and knee isokinetic muscular function were compared and analyzed. [Results] Regarding the aerobic exercise capacity test, significant differences were observed in maximal oxygen uptake and anaerobic threshold between both groups. For the anaerobic power test, no significant difference was observed in peak power and average power between the groups; however, a significant difference in fatigue index was noted. Regarding the knee isokinetic muscular test, no significant difference was noted in knee flexion, extension, and flexion/extension ratio between both groups. [Conclusion] Lower extremity injury was associated with reduced aerobic exercise capacity and a higher fatigue index with respect to anaerobic exercise capacity. Therefore, it seems necessary to establish post-injury training programs that improve aerobic and anaerobic exercise capacity for soccer players who experience lower extremity injury.

  18. Specificity of the femoral slump test for the assessment of experimentally induced anterior knee pain.

    PubMed

    Lai, Weng-Hang; Shih, Yi-Fen; Lin, Pei-Ling; Chen, Wen-Yin; Ma, Hsiao-Li

    2012-12-01

    To assess the specificity of the femoral slump test (FST) when assessing experimentally induced anterior knee pain. Cross-sectional, exploratory study. Research laboratory. Asymptomatic subjects (N=12; 6 men; 6 women) for the study. An experimental pain model was used to simulate anterior knee pain by injecting .25 mL of hypertonic saline solution (5% NaCl) into the medial infrapatellar fat pad. Not applicable. The changes in pain intensity and diameter after applying the structure differential maneuver (neck flexion/extension) during the FST were recorded and analyzed. Results revealed that the structure differential maneuver of the FST did not alter the pain intensity or diameter in 9 (neck extension) and 10 (neck flexion) out of 12 subjects, which meant that the FST provided appropriate testing responses in 75% to 83% cases when the anterior knee pain did not originate in neural tissues. The FST had a specificity of more than .75 when detecting nerve mechanosensitivity problems of anterior knee pain. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  19. [In situ suture repair procedure of knee dislocation with multiple-ligament injury at acute stage].

    PubMed

    Ye, Jingbing; Luo, Dahui; Fu, Weili; He, Xin; Li, Jian

    2009-09-01

    To investigate the method and the short term clinical effectiveness of in situ suture repair procedure of knee dislocation with multiple-ligament injury at acute stage. From February 2006 to November 2007, 9 patients suffering from single knee closed dislocation with multiple-ligament injury underwent open in situ suture repair procedure with non-absorbable thread and managements of other combined injuries simultaneously. Nine patients included 6 males and 3 females, aged 34-52 years old. The injured knees were left side in 4 cases and right side in 5 cases. Injuries were caused by traffic accident in 8 cases and heavy-weight crushing in 1 case. EMRI and arthroscopic examination showed that all patients suffered from the avulsion injuries of anterior cruciate ligament and posterior cruciate ligament. The time from injury to operation was 4 to 7 days with an average of 5.1 days. No bacterial arthritis occurred after operation. Subcutaneous ligated fat occurred and cured after symptomatic treatment in 2 cases, other incisions healed by first intension. All patients were followed up 12 months. At 12 months postoperatively, 2 patients' flexion range of the suffering knees lost 10 degrees when to compared with normal knees, and the range of motion was from 0 to 125 degrees. The Lysholm knee scores were 83-92 (average 86.3), the results were excellent in 3 cases and good in 6 cases. The posterior drawer test and anterior drawer test were one-degree positive in 3 cases respectively; the Lachman tests were one-degree positive in 5 cases, lateral stress tests were negative in all cases. In situ suture repair procedure of knee dislocation with multiple-ligament injury at acute stage has the advantages such as reliable fixation, simultaneous management of other combined injuries and satisfactory short term effect.

  20. Sidestep and crossover lower limb kinematics during a prolonged sport-like agility test.

    PubMed

    Potter, Danielle; Reidinger, Kellie; Szymialowicz, Rebecca; Martin, Thomas; Dione, Donald; Feinn, Richard; Wallace, David; Garbalosa, Juan C

    2014-10-01

    Non-contact anterior cruciate ligament (ACL) injuries in athletes occur more often towards the end of athletic competitions. However, the exact mechanisms of how prolonged activity increases the risk for ACL injuries are not clear. To determine the effect of prolonged activity on the hip and knee kinematics observed during self-selected cutting maneuvers performed in a timed agility test. Nineteen female Division I collegiate soccer players completed a self-selected cutting agility test until they were unable to meet a set performance time (one standard deviation of the average baseline trial). Using the 3D dimensional coordinate data the cut type was identified by the principle investigators. The 3D hip and knee angles at 32ms post heel strike were analyzed using a two-factor, linear mixed model to assess the effect of prolonged activity and cut type on the recorded mean hip and knee angles. Athletes performed either sidestep or crossover cuts. An effect of cut type and prolonged activity was seen at the hip and knee. During the prolonged activity trials, the knee was relatively more adducted and both the hip and knee were less flexed than during the baseline trials regardless of cut type. Regardless of activity status, during sidestep cuts, the hip was more internally rotated and abducted, and less flexed than during crossover cuts while the knee was more abducted and less flexed during the sidestep than crossover cuts. During a sport-like agility test, prolonged activity appears to predispose the athlete to position their knee in a more extended and abducted posture and their hip in a more extended posture. This position has been suggested to place stress on the ACL and potentially increase the risk for injury. Clinicians may want to consider the effects of prolonged activity on biomechanical risk factors for sustaining ACL injuries in the design of intervention strategies to prevent ACL injuries. Level 4.

  1. Reliability and concurrent validity of the Dutch hip and knee replacement expectations surveys

    PubMed Central

    2010-01-01

    Background Preoperative expectations of outcome of total hip and knee arthroplasty are important determinants of patients' satisfaction and functional outcome. Aims of the study were (1) to translate the Hospital for Special Surgery Hip Replacement Expectations Survey and Knee Replacement Expectations Survey into Dutch and (2) to study test-retest reliability and concurrent validity. Methods Patients scheduled for total hip (N = 112) or knee replacement (N = 101) were sent the Dutch Expectations Surveys twice with a 2 week interval to determine test-retest reliability. To determine concurrent validity, the Expectation WOMAC was sent. Results The results for the Dutch Hip Replacement Expectations Survey revealed good test-retest reliability (ICC 0.87), no bias and good internal consistency (alpha 0.86) (N = 72). The correlation between the Hip Expectations Score and the Expectation WOMAC score was 0.59 (N = 86). The results for the Dutch Knee Replacement Expectations Survey revealed good test-retest reliability (ICC 0.79), no bias and good internal consistency (alpha 0.91) (N = 46). The correlation with the Expectation WOMAC score was 0.52 (N = 57). Conclusions Both Dutch Expectations Surveys are reliable instruments to determine patients' expectations before total hip or knee arthroplasty. As for concurrent validity, the correlation between both surveys and the Expectation WOMAC was moderate confirming that the same construct was determined. However, patients scored systematically lower on the Expectation WOMAC compared to the Dutch Expectation Surveys. Research on patients' expectations before total hip and knee replacement has only been performed in a limited amount of countries. With the Dutch Expectations Surveys it is now possible to determine patients' expectations in another culture and healthcare setting. PMID:20958990

  2. Reliability and concurrent validity of the Dutch hip and knee replacement expectations surveys.

    PubMed

    van den Akker-Scheek, Inge; van Raay, Jos J A M; Reininga, Inge H F; Bulstra, Sjoerd K; Zijlstra, Wiebren; Stevens, Martin

    2010-10-19

    Preoperative expectations of outcome of total hip and knee arthroplasty are important determinants of patients' satisfaction and functional outcome. Aims of the study were (1) to translate the Hospital for Special Surgery Hip Replacement Expectations Survey and Knee Replacement Expectations Survey into Dutch and (2) to study test-retest reliability and concurrent validity. Patients scheduled for total hip (N = 112) or knee replacement (N = 101) were sent the Dutch Expectations Surveys twice with a 2 week interval to determine test-retest reliability. To determine concurrent validity, the Expectation WOMAC was sent. The results for the Dutch Hip Replacement Expectations Survey revealed good test-retest reliability (ICC 0.87), no bias and good internal consistency (alpha 0.86) (N = 72). The correlation between the Hip Expectations Score and the Expectation WOMAC score was 0.59 (N = 86). The results for the Dutch Knee Replacement Expectations Survey revealed good test-retest reliability (ICC 0.79), no bias and good internal consistency (alpha 0.91) (N = 46). The correlation with the Expectation WOMAC score was 0.52 (N = 57). Both Dutch Expectations Surveys are reliable instruments to determine patients' expectations before total hip or knee arthroplasty. As for concurrent validity, the correlation between both surveys and the Expectation WOMAC was moderate confirming that the same construct was determined. However, patients scored systematically lower on the Expectation WOMAC compared to the Dutch Expectation Surveys. Research on patients' expectations before total hip and knee replacement has only been performed in a limited amount of countries. With the Dutch Expectations Surveys it is now possible to determine patients' expectations in another culture and healthcare setting.

  3. The role of synovial fluid analysis in the detection of periprosthetic hip and knee infections: a systematic review and meta-analysis.

    PubMed

    De Fine, Marcello; Giavaresi, Gianluca; Fini, Milena; Illuminati, Andrea; Terrando, Silvio; Pignatti, Giovanni

    2018-05-01

    This study tried to ascertain (1) the accuracy of synovial fluid white blood cell count and polymorphonucleate percentage in the diagnosis of periprosthetic hip and knee infections, (2) which test yielded superior test performance, and (3) the influence on diagnostic accuracy of study characteristics such as patient number, study design, study level, anatomic site, and threshold value. A systematic search was conducted including papers assessing more effective cutoffs for synovial fluid tests, having comparative design, evaluating an exclusive cohort of hip or knee prostheses, including a clear definition of infected cases, and reporting sufficient data for the calculation of true-positive, false-positive, false-negative, and true-negative. A total of 375 articles were collected and, given the inclusion criteria, ten manuscripts were included. These studies assessed 1155 hip prostheses (276 infected cases) and 1235 knee prostheses (401 infected cases). The specificity of synovial fluid white blood cell count was significantly increased by using the threshold value ≥ 3000 cell/μL (p = 0.006); the sensitivity of polymorphonucleate percentage was significantly higher in detecting knee infections (p = 0.034). Both tests had a high specificity and sensitivity in detecting periprosthetic joint infections, and no clear superiority of one over the other existed. Furthermore, cutoff and anatomic site significantly influenced synovial fluid white blood cell count and polymorphonucleate percentage, respectively. Synovial fluid analysis is adequate in differentiating patients with periprosthetic hip and knee infections. Our data confirms international guidelines suggesting the use of 3000 cell/μL as cutoff threshold for synovial fluid white blood cell count. Since an anatomic site effect has been demonstrated, the goal of future studies will be to identify different cutoffs for hip and knee prostheses.

  4. Performance on the Functional Movement Screen™ is related to hop performance, but not to hip and knee strength in collegiate football players

    PubMed Central

    Willigenburg, Nienke; Hewett, Timothy E.

    2016-01-01

    Objective To define the relationship between FMS™ scores and hop performance, hip strength, and knee strength in collegiate football players. Design Cross-sectional cohort. Participants Freshmen of a division I collegiate American football team (n=59). Main Outcome Measures The athletes performed the FMS™, as well as a variety of hop tests, isokinetic knee strength and isometric hip strength tasks. We recorded total FMS™ score, peak strength and hop performance, and we calculated asymmetries between legs on the different tasks. Spearman’s correlation coefficients quantified the relationships these measures, and chi-square analyses compared the number of athletes with asymmetries on the different tasks. Results We observed significant correlations (r=0.38–0.56, p≤0.02) between FMS™ scores and hop distance, but not between FMS™ scores and hip or knee strength (all p≥0.21). The amount of asymmetry on the FMS™ test was significantly correlated to the amount of asymmetry on the timed 6m hop (r=0.44, p<0.01), but not to hip or knee strength asymmetries between limbs (all p≥0.34). Conclusions FMS™ score was positively correlated to hop distance, and limb asymmetry in FMS™ tasks was correlated to limb asymmetry in 6m hop time in football players. No significant correlations were observed between FMS™ score and hip and knee strength, or between FMS™ asymmetry and asymmetries in hip and knee strength between limbs. These results indicate that a simple hop for distance test may be a time and cost efficient alternative to FMS™ testing in athletes and that functional asymmetries between limbs do not coincide with strength asymmetries. PMID:26886801

  5. Performance on the Functional Movement Screen Is Related to Hop Performance But Not to Hip and Knee Strength in Collegiate Football Players.

    PubMed

    Willigenburg, Nienke; Hewett, Timothy E

    2017-03-01

    To define the relationship between Functional Movement Screen (FMS) scores and hop performance, hip strength, and knee strength in collegiate football players. Cross-sectional cohort. Freshmen of a Division I collegiate American football team (n = 59). The athletes performed the FMS, and also a variety of hop tests, isokinetic knee strength, and isometric hip strength tasks. We recorded total FMS score, peak strength, and hop performance, and we calculated asymmetries between legs on the different tasks. Spearman correlation coefficients quantified the relationships between these measures, and χ analyses compared the number of athletes with asymmetries on the different tasks. We observed significant correlations (r = 0.38-0.56, P ≤ 0.02) between FMS scores and hop distance but not between FMS scores and hip or knee strength (all P ≥ 0.21). The amount of asymmetry on the FMS test was significantly correlated to the amount of asymmetry on the timed 6-m hop (r = 0.44, P < 0.01) but not to hip or knee strength asymmetries between limbs (all P ≥ 0.34). Functional Movement Screen score was positively correlated to hop distance, and limb asymmetry in FMS tasks was correlated to limb asymmetry in 6-m hop time in football players. No significant correlations were observed between FMS score and hip and knee strength or between FMS asymmetry and asymmetries in hip and knee strength between limbs. These results indicate that a simple hop for distance test may be a time-efficient and cost-efficient alternative to FMS testing in athletes and that functional asymmetries between limbs do not coincide with strength asymmetries.

  6. Variability of Measurement of Patellofemoral Indices with Knee Flexion and Quadriceps Contraction: An MRI-Based Anatomical Study

    PubMed Central

    Laugharne, Edward; Bali, Navi; Purushothamdas, Sanjay; Almallah, Faris; Kundra, Rik

    2016-01-01

    Purpose The purpose of this study was to investigate the impact of varying knee flexion and quadriceps activity on patellofemoral indices measured on magnetic resonance imaging (MRI). Materials and Methods MRI of the knee was performed in 20 patients for indications other than patellar or patellofemoral pathology. Axial and sagittal sequences were performed in full extension of the knee with the quadriceps relaxed, full extension of the knee with the quadriceps contracted, 30° flexion of the knee with the quadriceps relaxed, and 30° flexion with the quadriceps contracted. Bisect offset, patella tilt angle, Insall-Salvati ratio and Caton-Deschamps index were measured. Results With the knee flexed to 30° and quadriceps relaxed, the mean values of patellar tilt angle, bisect offset, Insall-Salvati ratio and Caton-Deschamps index were all within normal limits. With the knee extended and quadriceps contracted, the mean patellar tilt angle (normal value, <15°) was 14.6° and the bisect offset (normal value, <65%) was 65%, while the Caton-Deschamps index was 1.34 (normal range, 0.6 to 1.3). With the knee extended and quadriceps relaxed, the mean Caton-Deschamps index was 1.31. Conclusions MRI scanning of the knee in extension with the quadriceps contracted leads to elevated patellofemoral indices. MRI taken with the knee in 30° of flexion allows more reliable assessment of the patellofemoral joint and minimises the confounding effect of quadriceps contraction. PMID:27894177

  7. THE INFLUENCE OF SEX AND MATURATION ON LANDING BIOMECHANICS: IMPLICATIONS FOR ACL INJURY

    PubMed Central

    Sigward, S. M.; Pollard, C. D.; Powers, C. M.

    2010-01-01

    During landing and cutting, females exhibit greater frontal plane moments at the knee (internal knee adductor moments or external knee abduction moments) and favor use of the knee extensors over the hip extensors to attenuate impact forces when compared to males. However, it is not known when this biomechanical profile emerges. The purpose of this study was to compare landing biomechanics between sexes across maturation levels. One hundred and nineteen male and female soccer players (9–22 years) participated. Subjects were grouped based on maturational development. Lower extremity kinematics and kinetics were obtained during a drop-land task. Dependent variables included the average internal knee adductor moment and sagittal plane knee/hip moment and energy absorption ratios during the deceleration phase of landing. When averaged across maturation levels, females demonstrated greater internal knee adductor moments (0.06±0.03 vs. 0.01±0.02 Nm/kg*m; P<0.005), knee/hip extensor moment ratios (2.0±0.1 vs. 1.4±0.1 Nm/kg*m; P<0.001), and knee/hip energy absorption ratios (2.9±0.1 vs. 1.96±0.1 Nm/kg*m; P<0.001) compared to males. Higher knee adductor moments combined with disproportionate use of knee extensors relative to hip extensors observed in females reflects a biomechanical pattern that increases ACL loading. This biomechanical strategy already was established in pre-pubertal female athletes. PMID:21210853

  8. Real-Time Tracking of Knee Adduction Moment in Patients with Knee Osteoarthritis

    PubMed Central

    Kang, Sang Hoon; Lee, Song Joo; Zhang, Li-Qun

    2014-01-01

    Background The external knee adduction moment (EKAM) is closely associated with the presence, progression, and severity of knee osteoarthritis (OA). However, there is a lack of convenient and practical method to estimate and track in real-time the EKAM of patients with knee OA for clinical evaluation and gait training, especially outside of gait laboratories. New Method A real-time EKAM estimation method was developed and applied to track and investigate the EKAM and other knee moments during stepping on an elliptical trainer in both healthy subjects and a patient with knee OA. Results Substantial changes were observed in the EKAM and other knee moments during stepping in the patient with knee OA. Comparison with Existing Method(s) This is the first study to develop and test feasibility of real-time tracking method of the EKAM on patients with knee OA using 3-D inverse dynamics. Conclusions The study provides us an accurate and practical method to evaluate in real-time the critical EKAM associated with knee OA, which is expected to help us to diagnose and evaluate patients with knee OA and provide the patients with real-time EKAM feedback rehabilitation training. PMID:24361759

  9. Human torque velocity adaptations to sprint, endurance, or combined modes of training

    NASA Technical Reports Server (NTRS)

    Shealy, M. J.; Callister, R.; Dudley, G. A.; Fleck, S. J.

    1992-01-01

    We had groups of athletes perform sprint and endurance run training independently or concurrently for 8 weeks to examine the voluntary in vivo mechanical responses to each type of training. Pre- and posttraining angle-specific peak torque during knee extension and flexion were determined at 0, 0.84, 1.65, 2.51, 3.35, 4.19, and 5.03 radian.sec-1 and normalized for lean body mass. Knee extension torque in the sprint-trained group increased across all test velocities, the endurance-trained group increased at 2.51, 3.34, 4.19, and 5.03 radian.sec-1, and the group performing the combined training showed no change at any velocity. Knee flexion torque of the sprint and combined groups decreased at 0.84, 1.65, and 2.51 radian.sec-1. Knee flexion torque in the sprint-trained group also decreased at 0 radian.sec-1 and in the combined group at 3.34 radian.sec-1. Knee flexion torque in the endurance-trained group showed no change at any velocity of contraction. Mean knee flexion:extension ratios across the test velocities significantly decreased in the sprint-trained group. Knee extension endurance during 30 seconds of maximal contractions significantly increased in all groups. Only the sprint-trained group showed a significant increase in endurance of the knee flexors. These data suggest that changes in the voluntary in vivo mechanical characteristics of knee extensor and flexor skeletal muscles are specific to the type of run training performed.

  10. Definition and evaluation of testing scenarios for knee wear simulation under conditions of highly demanding daily activities.

    PubMed

    Schwiesau, Jens; Schilling, Carolin; Kaddick, Christian; Utzschneider, Sandra; Jansson, Volkmar; Fritz, Bernhard; Blömer, Wilhelm; Grupp, Thomas M

    2013-05-01

    The objective of our study was the definition of testing scenarios for knee wear simulation under various highly demanding daily activities of patients after total knee arthroplasty. This was mainly based on a review of published data on knee kinematics and kinetics followed by the evaluation of the accuracy and precision of a new experimental setup. We combined tibio-femoral load and kinematic data reported in the literature to develop deep squatting loading profiles for simulator input. A servo-hydraulic knee wear simulator was customised with a capability of a maximum flexion of 120°, a tibio-femoral load of 5000N, an anterior-posterior (AP) shear force of ±1000N and an internal-external (IE) rotational torque of ±50Nm to simulate highly demanding patient activities. During the evaluation of the newly configurated simulator the ability of the test machine to apply the required load and torque profiles and the flexion kinematics in a precise manner was examined by nominal-actual profile comparisons monitored periodically during subsequent knee wear simulation. For the flexion kinematics under displacement control a delayed actuator response of approximately 0.05s was inevitable due to the inertia of masses in movement of the coupled knee wear stations 1-3 during all applied activities. The axial load and IE torque is applied in an effective manner without substantial deviations between nominal and actual load and torque profiles. During the first third of the motion cycle a marked deviation between nominal and actual AP shear load profiles has to be noticed but without any expected measurable effect on the latter wear simulation due to the fact that the load values are well within the peak magnitude of the nominal load amplitude. In conclusion the described testing method will be an important tool to have more realistic knee wear simulations based on load conditions of the knee joint during activities of daily living. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  11. Translation and cross-cultural adaptation of the lower extremity functional scale into a Brazilian Portuguese version and validation on patients with knee injuries.

    PubMed

    Metsavaht, Leonardo; Leporace, Gustavo; Riberto, Marcelo; Sposito, Maria Matilde M; Del Castillo, Letícia N C; Oliveira, Liszt P; Batista, Luiz Alberto

    2012-11-01

    Clinical measurement. To translate and culturally adapt the Lower Extremity Functional Scale (LEFS) into a Brazilian Portuguese version, and to test the construct and content validity and reliability of this version in patients with knee injuries. There is no Brazilian Portuguese version of an instrument to assess the function of the lower extremity after orthopaedic injury. The translation of the original English version of the LEFS into a Brazilian Portuguese version was accomplished using standard guidelines and tested in 31 patients with knee injuries. Subsequently, 87 patients with a variety of knee disorders completed the Brazilian Portuguese LEFS, the Medical Outcomes Study 36-Item Short-Form Health Survey, the Western Ontario and McMaster Universities Osteoarthritis Index, and the International Knee Documentation Committee Subjective Knee Evaluation Form and a visual analog scale for pain. All patients were retested within 2 days to determine reliability of these measures. Validation was assessed by determining the level of association between the Brazilian Portuguese LEFS and the other outcome measures. Reliability was documented by calculating internal consistency, test-retest reliability, and standard error of measurement. The Brazilian Portuguese LEFS had a high level of association with the physical component of the Medical Outcomes Study 36-Item Short-Form Health Survey (r = 0.82), the Western Ontario and McMaster Universities Osteoarthritis Index (r = 0.87), the International Knee Documentation Committee Subjective Knee Evaluation Form (r = 0.82), and the pain visual analog scale (r = -0.60) (all, P<.05). The Brazilian Portuguese LEFS had a low level of association with the mental component of the Medical Outcomes Study 36-Item Short-Form Health Survey (r = 0.38, P<.05). The internal consistency (Cronbach α = .952) and test-retest reliability (intraclass correlation coefficient = 0.957) of the Brazilian Portuguese version of the LEFS were high. The standard error of measurement was low (3.6) and the agreement was considered high, demonstrated by the small differences between test and retest and the narrow limit of agreement, as observed in Bland-Altman and survival-agreement plots. The translation of the LEFS into a Brazilian Portuguese version was successful in preserving the semantic and measurement properties of the original version and was shown to be valid and reliable in a Brazilian population with knee injuries.

  12. Sports Activity after Low-contact-stress Total Knee Arthroplasty – A long term follow-up study

    PubMed Central

    Vielgut, Ines; Leitner, Lukas; Kastner, Norbert; Radl, Roman; Leithner, Andreas; Sadoghi, Patrick

    2016-01-01

    The purpose of this study was to provide comprehensive long-term data about sports activity levels in patients following total knee arthroplasty (TKA) and to determine the impact of pre-operative function, pain and specific performed sports on the results. 236 patients who have undergone TKA for severe osteoarthritis of the knee were asked to provide specific information regarding exercised types of sports before surgery and after at least 10 years following TKA. Pre- and postoperative function and pain were evaluated by the use of Tegner-, WOMAC- and VAS Score. After a mean of 14.9 years, a significant improvement regarding pain and function was observed. Pre-operative Tegner- and WOMAC scores revealed significant positive correlations with the post-operative Tegner-Score. Accordingly, a high percentage of patients (70.9%) stayed actively involved in sports. Nevertheless, the number of performing patients has decreased according to the sports impact. 71.3% continued practising low-impact-, 43.7% intermediate-impact sports whereas only 16.4% kept performing high impact sports. We conclude that TKA is highly effective in long-time pain reduction as well as improvement of function. Additionally, we found considerable sports activities preserved in the investigated series. However, sports activities in particular, seem to decrease according to the impact of sports. PMID:27090945

  13. Sports Activity after Low-contact-stress Total Knee Arthroplasty - A long term follow-up study.

    PubMed

    Vielgut, Ines; Leitner, Lukas; Kastner, Norbert; Radl, Roman; Leithner, Andreas; Sadoghi, Patrick

    2016-04-19

    The purpose of this study was to provide comprehensive long-term data about sports activity levels in patients following total knee arthroplasty (TKA) and to determine the impact of pre-operative function, pain and specific performed sports on the results. 236 patients who have undergone TKA for severe osteoarthritis of the knee were asked to provide specific information regarding exercised types of sports before surgery and after at least 10 years following TKA. Pre- and postoperative function and pain were evaluated by the use of Tegner-, WOMAC- and VAS Score. After a mean of 14.9 years, a significant improvement regarding pain and function was observed. Pre-operative Tegner- and WOMAC scores revealed significant positive correlations with the post-operative Tegner-Score. Accordingly, a high percentage of patients (70.9%) stayed actively involved in sports. Nevertheless, the number of performing patients has decreased according to the sports impact. 71.3% continued practising low-impact-, 43.7% intermediate-impact sports whereas only 16.4% kept performing high impact sports. We conclude that TKA is highly effective in long-time pain reduction as well as improvement of function. Additionally, we found considerable sports activities preserved in the investigated series. However, sports activities in particular, seem to decrease according to the impact of sports.

  14. Translational and rotational knee joint stability in anterior and posterior cruciate-retaining knee arthroplasty.

    PubMed

    Lo, JiaHsuan; Müller, Otto; Dilger, Torsten; Wülker, Nikolaus; Wünschel, Markus

    2011-12-01

    This study investigated passive translational and rotational stability properties of the intact knee joint, after bicruciate-retaining bi-compartmental knee arthroplasty (BKA) and after posterior cruciate retaining total knee arthroplasty (TKA). Fourteen human cadaveric knee specimens were used in this study, and a robotic manipulator with six-axis force/torque sensor was used to test the joint laxity in anterior-posterior translation, valgus-varus, and internal-external rotation. The results show the knee joint stability after bicruciate-retaining BKA is similar to that of the native knee. On the other hand, the PCL-retaining TKA results in inferior joint stability in valgus, varus, external rotation, anterior and, surprisingly, posterior directions. Our findings suggest that, provided functional ligamentous structures, bicruciate-retaining BKA is a biomechanically attractive treatment for joint degenerative disease. Copyright © 2010 Elsevier B.V. All rights reserved.

  15. Continuous femoral versus epidural block for attainment of 120° knee flexion after total knee arthroplasty: a randomized controlled trial.

    PubMed

    Sakai, Norihiro; Inoue, Takaya; Kunugiza, Yasuo; Tomita, Tetsuya; Mashimo, Takashi

    2013-05-01

    We conducted the prospective randomized controlled trial to test that continuous femoral nerve block (CFNB) improves attainment of 120° knee flexion compared to continuous epidural analgesia (CEA). Sixty-six patients scheduled for unilateral total knee arthroplasty were randomized into two groups; infusion of ropivacaine 0.15% into CEA or CFNB to third postoperative days. We studied the time required to attain 120° knee flexion, variations in thigh and calf circumferences around the treated knee, pain scores, rehabilitation milestones, the need for adjuvant analgesics, and side effects. CFNB patients attained earlier knee flexion to 120°, lower variations in thigh and calf circumferences, less pain during rehabilitation, and less need for adjuvant analgesics. CFNB is a better pain management strategy that accelerates knee flexion rehabilitation. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. Impact of Patient Sex on Clinical Outcomes

    PubMed Central

    Teitsma, Xavier M.; van der Hoeven, Henk; Tamminga, Rob; de Bie, Rob A.

    2014-01-01

    Background: The Combined Quality Care Anterior Cruciate Ligament registry provides data for clinical research regarding primary anterior cruciate ligament (ACL) surgery. Purpose: To explore the data with regard to the clinical outcomes between sexes after ACL reconstruction in a Dutch population. Study Design: Cohort study; Level of evidence, 3. Methods: Data involving patients diagnosed with an ACL tear and eligible for surgery were recorded. Isokinetic muscle strength, functional muscle performance, and anterior-posterior translation of the knee joint were documented preoperatively and at 3, 6, 9, and 12 months postoperatively. Patients completed the Knee Injury and Osteoarthritis Outcome Score (KOOS), Lysholm, and Tegner rating scales during each examination using a web-based questionnaire. Results: Approximately 90% of ACL injuries occurred during sport activities. The mean (SD) age at surgery was 28 (11) years for both men and women, and the majority of patients were treated with hamstring tendon autografts (94%). Four percent received bone–patellar tendon–bone autografts, and 2% of the patients received other grafts. Preoperatively, the KOOS, Lysholm, and Tegner scores were significantly higher in males. Twelve months postoperatively, both sexes showed comparable isokinetic strength (P = .336), knee laxity (P = .680), and hop test for distance (P = .122) when comparing the injured with the uninjured side. Self-reported knee function was comparable between sexes as assessed by the KOOS (P = .202), Lysholm (P = .872), and Tegner (P = .767) questionnaires during the 12-month follow-up. Conclusion: One year after ACL surgery, all patients had improved greatly, showing only minor differences between sexes. The male group showed slightly better results when evaluating self-reported knee questionnaires. Comparable outcomes and knee function between sexes can therefore be presumed with patients who are treated with hamstring tendon autografts in a Dutch population. Clinical Relevance: These results can be used during the clinical evaluation of patients who are eligible for ACL reconstruction. PMID:26535365

  17. Clinical high-resolution mapping of the proteoglycan-bound water fraction in articular cartilage of the human knee joint.

    PubMed

    Bouhrara, Mustapha; Reiter, David A; Sexton, Kyle W; Bergeron, Christopher M; Zukley, Linda M; Spencer, Richard G

    2017-11-01

    We applied our recently introduced Bayesian analytic method to achieve clinically-feasible in-vivo mapping of the proteoglycan water fraction (PgWF) of human knee cartilage with improved spatial resolution and stability as compared to existing methods. Multicomponent driven equilibrium single-pulse observation of T 1 and T 2 (mcDESPOT) datasets were acquired from the knees of two healthy young subjects and one older subject with previous knee injury. Each dataset was processed using Bayesian Monte Carlo (BMC) analysis incorporating a two-component tissue model. We assessed the performance and reproducibility of BMC and of the conventional analysis of stochastic region contraction (SRC) in the estimation of PgWF. Stability of the BMC analysis of PgWF was tested by comparing independent high-resolution (HR) datasets from each of the two young subjects. Unlike SRC, the BMC-derived maps from the two HR datasets were essentially identical. Furthermore, SRC maps showed substantial random variation in estimated PgWF, and mean values that differed from those obtained using BMC. In addition, PgWF maps derived from conventional low-resolution (LR) datasets exhibited partial volume and magnetic susceptibility effects. These artifacts were absent in HR PgWF images. Finally, our analysis showed regional variation in PgWF estimates, and substantially higher values in the younger subjects as compared to the older subject. BMC-mcDESPOT permits HR in-vivo mapping of PgWF in human knee cartilage in a clinically-feasible acquisition time. HR mapping reduces the impact of partial volume and magnetic susceptibility artifacts compared to LR mapping. Finally, BMC-mcDESPOT demonstrated excellent reproducibility in the determination of PgWF. Published by Elsevier Inc.

  18. Biomechanical analysis of gait waveform data: exploring differences between shod and barefoot running in habitually shod runners.

    PubMed

    Tam, Nicholas; Prins, Danielle; Divekar, Nikhil V; Lamberts, Robert P

    2017-10-01

    The aim of this study was to utilise one-dimensional statistical parametric mapping to compare differences between biomechanical and electromyographical waveforms in runners when running in barefoot or shod conditions. Fifty habitually shod runners were assessed during overground running at their current 10-km race running speed. Electromyography, kinematics and ground reaction forces were collected during these running trials. Joint kinetics were calculated using inverse dynamics. One-dimensional statistical parametric mapping one sample t-test was conducted to assess differences over an entire gait cycle on the variables of interest when barefoot or shod (p<0.05). Only sagittal plane differences were found between barefoot and shod conditions at the knee during late stance (18-23% of the gait cycle) and swing phase (74-90%); at the ankle early stance (0-6%), mid-stance (28-38%) and swing phase (81-100%). Differences in sagittal plane moments were also found at the ankle during early stance (2, 4-5%) and knee during early stance (5-11%). Condition differences were also found in vertical ground reaction force during early stance between (3-10%). An acute bout of barefoot running in habitual shod runners invokes temporal differences throughout the gait cycle. Specifically, a co-ordinative responses between the knee and ankle joint in the sagittal plane with a delay in the impact transient peak; onset of the knee extension and ankle plantarflexion moment in the shod compared to barefoot condition was found. This appears to affect the delay in knee extension and ankle plantarflexion during late stance. This study provides a glimpse into the co-ordination of the lower limb when running in differing footwear. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Protocol for a single-centre, parallel-arm, randomised controlled superiority trial evaluating the effects of transcatheter arterial embolisation of abnormal knee neovasculature on pain, function and quality of life in people with knee osteoarthritis

    PubMed Central

    Landers, Steve; Hely, Andrew; Harrison, Benjamin; Maister, Nick; Hely, Rachael; Lane, Stephen E; Gill, Stephen D; Page, Richard S

    2017-01-01

    Introduction Symptomatic knee osteoarthritis (OA) is common. Advanced knee OA is successfully treated with joint replacement surgery, but effectively managing mild to moderate knee OA can be difficult. Angiogenesis increases with OA and might contribute to pain and structural damage. Modifying angiogenesis is a potential treatment pathway for OA. The aim of the current study is to determine whether transcatheter arterial embolisation of abnormal neovasculature arising from the genicular arterial branches improves knee pain, physical function and quality of life in people with mild to moderate symptomatic knee OA. Methods and analysis The study is a single centre, parallel-arm, double-blinded (participant and assessor), randomised controlled superiority trial with 1:1 random block allocation. Eligible participants have mild to moderate symptomatic knee OA and will be randomly assigned to receive either embolisation of aberrant knee neovasculature of genicular arterial branches or a placebo intervention. Outcome measures will be collected prior to the intervention and again 1, 6 and 12 months postintervention. The primary outcome is change in knee pain between baseline and 12 month assessment as measured by the Knee Injury and Osteoarthritis Outcome Score (KOOS). Secondary outcomes include change in self-reported physical function (KOOS), self-reported quality of life (KOOS, EuroQol: EQ-5D-5L), self-reported knee joint stiffness (KOOS), self-reported global change, 6 min walk test performance, and 30 s chair-stand test performance. Intention-to-treat analysis will be performed including all participants as randomised. To detect a mean between group difference in change pain of 20% at the one year reassessment with a two-sided significance level of α=0.05 and power of 80% using a two-sample t-test, we require 29 participants per arm which allows for 20% of participants to drop out. Ethics and dissemination Barwon Health Human Research Ethics Committee, 30 May 2016, (ref:15/101). Study results will be disseminated via peer-reviewed publications and conference presentations. Trial registration number Universal trial number U1111-1183-8503, Australian New Zealand Clinical Trials Registry, ACTRN12616001184460, approved 29 August 2016. PMID:28554913

  20. Protocol for a single-centre, parallel-arm, randomised controlled superiority trial evaluating the effects of transcatheter arterial embolisation of abnormal knee neovasculature on pain, function and quality of life in people with knee osteoarthritis.

    PubMed

    Landers, Steve; Hely, Andrew; Harrison, Benjamin; Maister, Nick; Hely, Rachael; Lane, Stephen E; Gill, Stephen D; Page, Richard S

    2017-05-29

    Symptomatic knee osteoarthritis (OA) is common. Advanced knee OA is successfully treated with joint replacement surgery, but effectively managing mild to moderate knee OA can be difficult. Angiogenesis increases with OA and might contribute to pain and structural damage. Modifying angiogenesis is a potential treatment pathway for OA. The aim of the current study is to determine whether transcatheter arterial embolisation of abnormal neovasculature arising from the genicular arterial branches improves knee pain, physical function and quality of life in people with mild to moderate symptomatic knee OA. The study is a single centre, parallel-arm, double-blinded (participant and assessor), randomised controlled superiority trial with 1:1 random block allocation. Eligible participants have mild to moderate symptomatic knee OA and will be randomly assigned to receive either embolisation of aberrant knee neovasculature of genicular arterial branches or a placebo intervention. Outcome measures will be collected prior to the intervention and again 1, 6 and 12 months postintervention. The primary outcome is change in knee pain between baseline and 12 month assessment as measured by the Knee Injury and Osteoarthritis Outcome Score (KOOS). Secondary outcomes include change in self-reported physical function (KOOS), self-reported quality of life (KOOS, EuroQol: EQ-5D-5L), self-reported knee joint stiffness (KOOS), self-reported global change, 6 min walk test performance, and 30 s chair-stand test performance. Intention-to-treat analysis will be performed including all participants as randomised. To detect a mean between group difference in change pain of 20% at the one year reassessment with a two-sided significance level of α=0.05 and power of 80% using a two-sample t-test, we require 29 participants per arm which allows for 20% of participants to drop out. Barwon Health Human Research Ethics Committee, 30 May 2016, (ref:15/101). Study results will be disseminated via peer-reviewed publications and conference presentations. Universal trial number U1111-1183-8503, Australian New Zealand Clinical Trials Registry, ACTRN12616001184460, approved 29 August 2016. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Internet-mediated physiotherapy and pain coping skills training for people with persistent knee pain (IMPACT - knee pain): a randomised controlled trial protocol.

    PubMed

    Dobson, Fiona; Hinman, Rana S; French, Simon; Rini, Christine; Keefe, Francis; Nelligan, Rachel; Abbott, J Haxby; Bryant, Christina; Staples, Margaret P; Dalwood, Andrew; Bennell, Kim L

    2014-08-13

    Persistent knee pain in people over 50 years of age is often attributable to knee osteoarthritis (OA), a common joint condition that causes physical and psychological dysfunction. Exercise and pain coping skills training (PCST) can help reduce the impact of persistent knee pain, however, access to health professionals who deliver these services can be challenging. With increasing access to the Internet, remotely delivered Internet-based treatment approaches may provide alternatives for healthcare delivery. This pragmatic randomised controlled trial will investigate whether an Internet-delivered intervention that combines PCST and physiotherapist-guided exercise (PCST + Ex) is more effective than online educational material (educational control) in people with persistent knee pain. We will recruit 148 people over 50 years of age with self-reported persistent knee pain consistent with knee OA from the Australian community. Following completion of baseline questionnaires, participants will be randomly allocated to access a 3-month intervention of either (i) online educational material, or (ii) the same online material plus an 8-module (once per week) Internet-based PCST program and seven Internet-delivered physiotherapy sessions with a home exercise programs to be performed 3 times per week. Outcomes will be measured at baseline, 3 months and 9 months with the primary time point at 3 months. Primary outcomes are average knee pain on walking (11-point numeric rating scale) and self-reported physical function (Western Ontario and McMaster Universities Osteoarthritis Index subscale). Secondary outcomes include additional measures of knee pain, health-related quality-of-life, perceived global change in symptoms, and potential moderators and mediators of outcomes including self-efficacy for pain management and function, pain coping attempts and pain catastrophising. Other measures of adherence, adverse events, harms, use of health services/co-interventions, and process measures including appropriateness and satisfaction of the intervention, will be collected at 3, 6 and 9 months. The findings will help determine the effectiveness and acceptability of Internet access to a combination of interventions that are known to be beneficial to people with persistent knee pain. This study has the potential to guide clinical practice towards innovative modes of healthcare provision. Australian New Zealand Clinical Trials Registry reference: ACTRN12614000243617.

  2. Force measurements in the medial meniscus posterior horn attachment: effects of anterior cruciate ligament removal.

    PubMed

    Markolf, Keith L; Jackson, Steven R; McAllister, David R

    2012-02-01

    Tears of the medial meniscus posterior horn attachment (PHA) occur clinically, and an anterior cruciate ligament (ACL)-deficient knee may be more vulnerable to this injury. The PHA forces from applied knee loadings will increase after removal of the ACL. Controlled laboratory study. A cap of bone containing the medial meniscus PHA was attached to a load cell that measured PHA tensile force. Posterior horn attachment forces were recorded before and after ACL removal during anteroposterior (AP) laxity testing at ±200 N and during passive knee extension tests with 5 N·m tibial torque and varus-valgus moment. Selected tests were also performed with 500 N joint load. For AP tests with no joint load, ACL removal increased laxity between 0° and 90° and increased PHA force generated by applied anterior tibial force between 30° and 90°. For AP tests with an intact ACL, application of joint load approximately doubled PHA forces. Anteroposterior testing of ACL-deficient knees was not possible with joint load because of bone cap failures from high PHA forces. Removal of the ACL during knee extension tests under joint load significantly increased PHA forces between 20° and 90° of flexion. For unloaded tests with applied tibial torque and varus-valgus moment, ACL removal had no significant effect on PHA forces. Applied anterior tibial force and external tibial torque were loading modes that produced relatively high PHA forces, presumably by impingement of the medial femoral condyle against the medial meniscus posterior horn rim. Under joint load, an ACL-deficient knee was particularly susceptible to PHA injury from applied anterior tibial force. Because tensile forces developed in the PHA are also borne by meniscus tissue near the attachment site, loading mechanisms that produce high PHA forces could also produce complete or partial radial tears near the posterior horn, a relatively common clinical observation.

  3. Wear simulation of total knee prostheses using load and kinematics waveforms from stair climbing.

    PubMed

    Abdel-Jaber, Sami; Belvedere, Claudio; Leardini, Alberto; Affatato, Saverio

    2015-11-05

    Knee wear simulators are meant to perform load cycles on knee implants under physiological conditions, matching exactly, if possible, those experienced at the replaced joint during daily living activities. Unfortunately, only conditions of low demanding level walking, specified in ISO-14243, are used conventionally during such tests. A recent study has provided a consistent knee kinematic and load data-set measured during stair climbing in patients implanted with a specific modern total knee prosthesis design. In the present study, wear simulation tests were performed for the first time using this data-set on the same prosthesis design. It was hypothesised that more demanding tasks would result in wear rates that differ from those observed in retrievals. Four prostheses for total knee arthroplasty were tested using a displacement-controlled knee wear simulator for two million cycles at 1.1 Hz, under kinematics and load conditions typical of stair climbing. After simulation, the corresponding damage scars on the bearings were qualified and compared with equivalent explanted prostheses. An average mass loss of 20.2±1.5 mg was found. Scanning digital microscopy revealed similar features, though the explant had a greater variety of damage modes, including a high prevalence of adhesive wear damage and burnishing in the overall articulating surface. This study confirmed that the results from wear simulation machines are strongly affected by kinematics and loads applied during simulations. Based on the present results for the full understanding of the current clinical failure of knee implants, a more comprehensive series of conditions are necessary for equivalent simulations in vitro. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. A Prospective Study of Overuse Knee Injuries Among Female Athletes With Muscle Imbalances and Structural Abnormalities

    PubMed Central

    Pescatello, Linda S.; Faghri, Pouran; Anderson, Jeffrey

    2004-01-01

    Objective: To prospectively examine the influence of hamstring-to-quadriceps (H:Q) ratio and structural abnormalities on the prevalence of overuse knee injuries among female collegiate athletes. Design and Setting: We used chi-square 2 × 2 contingency tables and the Fischer exact test to examine associations among H:Q ratios, structural abnormalities, and overuse knee injuries. Subjects: Fifty-three apparently healthy women (age = 19.4 ± 1.3 years, height = 167.6 ± 10.1 cm, mass = 65.0 ± 10.0 kg) from National Collegiate Athletic Association Division I women's field hockey (n = 23), soccer (n = 20), and basketball teams (n = 10) volunteered. Measurements: The H:Q ratio was determined from a preseason isokinetic test on a Biodex system at 60°/s and 300°/s. We measured athletes for genu recurvatum and Q-angles with a 14-in (35.56-cm) goniometer. Iliotibial band flexibility was assessed via the Ober test. Results: Ten overuse knee injuries (iliotibial band friction syndromes = 5, patellar tendinitis = 3, patellofemoral syndrome = 1, pes anserine tendinitis = 1) occurred in 9 athletes. The H:Q ratio below the normal range at 300°/s (P = 0.047) was associated with overuse knee injuries, as was the presence of genu recurvatum (P = 0.004). In addition, athletes possessing lower H:Q ratios at 300°/s and genu recurvatum incurred more overuse knee injuries than athletes without these abnormalities (P = 0.001). Conclusions: The presence of genu recurvatum and an H: Q ratio below normal range was associated with an increased prevalence of overuse knee injuries among female collegiate athletes. Further investigation is needed to clarify which preseason screening procedures may identify collegiate athletes who are susceptible to overuse knee injuries. PMID:15496997

  5. A Prospective Study of Overuse Knee Injuries Among Female Athletes With Muscle Imbalances and Structural Abnormalities.

    PubMed

    Devan, Michelle R; Pescatello, Linda S; Faghri, Pouran; Anderson, Jeffrey

    2004-09-01

    OBJECTIVE: To prospectively examine the influence of hamstring-to-quadriceps (H:Q) ratio and structural abnormalities on the prevalence of overuse knee injuries among female collegiate athletes. DESIGN AND SETTING: We used chi-square 2 x 2 contingency tables and the Fischer exact test to examine associations among H:Q ratios, structural abnormalities, and overuse knee injuries. SUBJECTS: Fifty-three apparently healthy women (age = 19.4 +/- 1.3 years, height = 167.6 +/- 10.1 cm, mass = 65.0 +/- 10.0 kg) from National Collegiate Athletic Association Division I women's field hockey (n = 23), soccer (n = 20), and basketball teams (n = 10) volunteered. MEASUREMENTS: The H:Q ratio was determined from a preseason isokinetic test on a Biodex system at 60 degrees /s and 300 degrees /s. We measured athletes for genu recurvatum and Q-angles with a 14-in (35.56-cm) goniometer. Iliotibial band flexibility was assessed via the Ober test. RESULTS: Ten overuse knee injuries (iliotibial band friction syndromes = 5, patellar tendinitis = 3, patellofemoral syndrome = 1, pes anserine tendinitis = 1) occurred in 9 athletes. The H:Q ratio below the normal range at 300 degrees /s (P = 0.047) was associated with overuse knee injuries, as was the presence of genu recurvatum (P = 0.004). In addition, athletes possessing lower H:Q ratios at 300 degrees /s and genu recurvatum incurred more overuse knee injuries than athletes without these abnormalities (P = 0.001). CONCLUSIONS: The presence of genu recurvatum and an H: Q ratio below normal range was associated with an increased prevalence of overuse knee injuries among female collegiate athletes. Further investigation is needed to clarify which preseason screening procedures may identify collegiate athletes who are susceptible to overuse knee injuries.

  6. Effect of tibial slope on the stability of the anterior cruciate ligament-deficient knee.

    PubMed

    Voos, James E; Suero, Eduardo M; Citak, Musa; Petrigliano, Frank P; Bosscher, Marianne R F; Citak, Mustafa; Wickiewicz, Thomas L; Pearle, Andrew D

    2012-08-01

    We aimed to quantify the effect of changes in tibial slope on the magnitude of anterior tibial translation (ATT) in the anterior cruciate ligament (ACL)-deficient knee during the Lachman and mechanized pivot shift tests. We hypothesized that increased posterior tibial slope would increase the amount of ATT of an ACL-deficient knee, while leveling the slope of the tibial plateau would decrease the amount of ATT. Lachman and mechanized pivot shift tests were performed on hip-to-toe cadaveric specimens, and ATT of the lateral and the medial compartments was measured using navigation (n = 11). The ACL was then sectioned. Stability testing was repeated, and ATT was recorded. A proximal tibial osteotomy in the sagittal plane was then performed achieving either +5 or -5° of tibial slope variation after which stability testing was repeated (n = 10). Sectioning the ACL resulted in a significant increase in ATT in both the Lachman and mechanized pivot shift tests (P < 0.05). Increasing or decreasing the slope of the tibial plateau had no effect on ATT during the Lachman test (n.s.). During the mechanized pivot shift tests, a 5° increase in posterior slope resulted in a significant increase in ATT compared to the native knee (P < 0.05), while a 5° decrease in slope reduced ATT to a level similar to that of the intact knee. Tibial slope changes did not affect the magnitude of translation during a Lachman test. However, large changes in tibial slope variation affected the magnitude of the pivot shift.

  7. What is the normal response to structural differentiation within the slump and straight leg raise tests?

    PubMed

    Herrington, Lee; Bendix, Katie; Cornwell, Catherine; Fielden, Nicola; Hankey, Karen

    2008-08-01

    The purpose of the study was to assess the effect of structural differentiation or sensitising manoeuvres on responses of normal subjects to standard neurodynamic tests of straight leg raise (SLR) and slump test. Eighty-eight (39 males and 49 females) asymptomatic subjects were examined (aged 18-39 mean age 21.9+/-4.1 years). Knee flexion angle was measured using a goniometer during the slump test in two conditions cervical flexion and extension. Hip flexion angle was measured using a goniometer during SLR test in two conditions; ankle dorsi-flexion and neutral. The change in knee flexion, following addition of the structural differentiating manoeuvre to the slump test, was a significant increase in knee flexion angle for both males (change in knee angle; 6.6+/-4.7 degrees /18.7+/-17.5%, p<0.01) and females (change in knee angle 5.4+/-5.8 degrees /17.6+/-23.7%, p<0.01), though showed no difference between sides (p>0.05). During the SLR test, a significant reduction in hip flexion occurred following structural differentiation for both groups (change in hip angle; males = 9.5+/-8.3 degrees /21.5+/-18.8%, p<0.01; females = 15.2+/-9.5 degrees /25.9+/-13.9%, p<0.01), though showed no difference between sides (p>0.05). Structural differentiating manoeuvres have a significant effect on test response in terms of range of movement even in normal asymptomatic individuals. These responses should be taken into account during the assessment clinical reasoning process.

  8. Generalised joint hypermobility and knee joint hypermobility: prevalence, knee joint symptoms and health-related quality of life in a Danish adult population.

    PubMed

    Junge, Tina; Henriksen, Peter; Hansen, Sebrina; Østengaard, Lasse; Golightly, Yvonne M; Juul-Kristensen, Birgit

    2017-10-27

    Several biomechanical factors, such as knee joint hypermobility (KJH), are suggested to play a role in the etiology of knee joint symptoms and knee osteoarthritis. Nevertheless, the prevalence or consequences of KJH solely or included in the classification of generalized joint hypermobility (GJHk) is unknown for a general population. Therefore, the objectives were to report the prevalence of self-reported GJHk and KJH, as well as the association of these conditions to knee joint symptoms, severity and duration of symptoms, and health-related quality of life (HRQoL) in a Danish adult population. This study is a cross-sectional population-based survey of 2056 Danish adults. Respondents received online questionnaires of GJHk and KJH, knee joint symptoms, the severity and duration of these, as well as HRQoL. Total response rate was 49% (n = 1006). The prevalence of self-reported GJHk and KJH was 13% and 23%, mostly representing women. More than half of the respondents with GJHk and KJH had knee joint symptoms. The odds for reporting knee joint symptoms, severity of knee joint symptoms and duration of knee joint symptoms were twice as high for respondents with GJHk and KJH. Respondents with GJHk and KJH reported lower HRQoL. GJHk and KJH were frequently reported in the Danish adult population, mostly in women. Respondents with GJHk and KJH were two times more likely to report knee joint-related symptoms such as pain, reduced performance of usual activity and lower HRQoL. The impact of these conditions on HRQoL is comparable with knee osteoarthritis. © 2017 Asia Pacific League of Associations for Rheumatology and John Wiley & Sons Australia, Ltd.

  9. Impact of knee support and shape of tabletop on rectum and prostate position

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steenbakkers, Roel; Duppen, Joop C.; Betgen, Anja

    2004-12-01

    Purpose: To evaluate the impact of different tabletops with or without a knee support on the position of the rectum, prostate, and bulb of the penis; and to evaluate the effect of these patient-positioning devices on treatment planning. Methods and materials: For 10 male volunteers, five MRI scans were made in four different positions: on a flat tabletop with knee support, on a flat tabletop without knee support, on a rounded tabletop with knee support, and on a rounded tabletop without knee support. The fifth scan was in the same position as the first. With image registration, the position differencesmore » of the rectum, prostate, and bulb of the penis were measured at several points in a sagittal plane through the central axis of the prostate. A planning target volume was generated from the delineated prostates with a margin of 10 mm in three dimensions. A three-field treatment plan with a prescribed dose of 78 Gy to the International Commission on Radiation Units and Measurements point was automatically generated from each planning target volume. Dose-volume histograms were calculated for all rectal walls. Results: The shape of the tabletop did not affect the rectum and prostate position. Addition of a knee support shifted the anterior and posterior rectal walls dorsally. For the anterior rectal wall, the maximum dorsal shift was 9.9 mm (standard error of the mean [SEM] 1.7 mm) at the top of the prostate. For the posterior rectal wall, the maximum dorsal shift was 10.2 mm (SEM 1.5 mm) at the middle of the prostate. Therefore, the rectal filling was pushed caudally when a knee support was added. The knee support caused a rotation of the prostate around the left-right axis at the apex (i.e., a dorsal rotation) by 5.6 deg (SEM 0.8 deg ) and shifts in the caudal and dorsal directions of 2.6 mm (SEM 0.4 cm) and 1.4 mm (SEM 0.6 mm), respectively. The position of the bulb of the penis was not influenced by the use of a knee support or rounded tabletop. The volume of the rectal wall receiving the same dose range (e.g., 40-75 Gy) was reduced by 3.5% (SEM 0.9%) when a knee support was added. No significant differences were observed between the first and fifth scan (flat tabletop with knee support) for all measured points, thereby excluding time trends. Conclusions: The rectum and prostate were significantly shifted dorsally by the use of a knee support. The rectum shifted more than the prostate, resulting in a dose benefit compared with irradiation without knee support. The shape of the tabletop did not influence the rectum or prostate position.« less

  10. In vivo kinematics of healthy male knees during squat and golf swing using image-matching techniques.

    PubMed

    Murakami, Koji; Hamai, Satoshi; Okazaki, Ken; Ikebe, Satoru; Shimoto, Takeshi; Hara, Daisuke; Mizu-uchi, Hideki; Higaki, Hidehiko; Iwamoto, Yukihide

    2016-03-01

    Participation in specific activities requires complex ranges of knee movements and activity-dependent kinematics. The purpose of this study was to investigate dynamic knee kinematics during squat and golf swing using image-matching techniques. Five healthy males performed squats and golf swings under periodic X-ray images at 10 frames per second. We analyzed the in vivo three-dimensional kinematic parameters of subjects' knees, namely the tibiofemoral flexion angle, anteroposterior (AP) translation, and internal-external rotation, using serial X-ray images and computed tomography-derived, digitally reconstructed radiographs. During squat from 0° to 140° of flexion, the femur moved about 25 mm posteriorly and rotated 19° externally relative to the tibia. Screw-home movement near extension, bicondylar rollback between 20° and 120° of flexion, and medial pivot motion at further flexion were observed. During golf swing, the leading and trailing knees (the left and right knees respectively in the right-handed golfer) showed approximately five millimeters and four millimeters of AP translation with 18° and 26° of axial rotation, respectively. A central pivot motion from set-up to top of the backswing, lateral pivot motion from top to ball impact, and medial pivot motion from impact to the end of follow-through were observed. The medial pivot motion was not always recognized during both activities, but a large range of axial rotation with bilateral condylar AP translations occurs during golf swing. This finding has important implications regarding the amount of acceptable AP translation and axial rotation at low flexion in replaced knees. IV. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. The association between lower extremity energy absorption and biomechanical factors related to anterior cruciate ligament injury.

    PubMed

    Norcross, Marc F; Blackburn, J Troy; Goerger, Benjamin M; Padua, Darin A

    2010-12-01

    Greater total energy absorption by the lower extremity musculature during landing may reduce stresses placed on capsuloligamentous tissues with differences in joint contributions to energy absorption potentially affecting anterior cruciate ligament injury risk. However, the relationships between energy absorption and prospectively identified biomechanical factors associated with non-contact anterior cruciate ligament injury have yet to be demonstrated. Sagittal plane total, hip, knee and ankle energy absorption, and peak vertical ground reaction force, anterior tibial shear force, knee flexion and knee valgus angles, and internal hip extension and knee varus moments were measured in 27 individuals (14 females, 13 males) performing double leg jump landings. Correlation coefficients assessed the relationships between energy absorption during three time intervals (initial impact phase, terminal phase, and total landing) and biomechanical factors related to anterior cruciate ligament injury. More favorable values of biomechanical factors related to non-contact anterior cruciate ligament injury were associated with: 1) Lesser total (R(2)=0.178-0.558), hip (R(2)=0.229-0.651) and ankle (R(2)=0.280), but greater knee (R(2)=0.147) energy absorption during the initial impact phase; 2) Greater total (R(2)=0.170-0.845), hip (R(2)=0.599), knee (R(2)=0.236-0.834), and ankle (R(2)=0.276) energy absorption during the terminal phase of landing; and 3) Greater knee (R(2)=0.158-0.709), but lesser hip (R(2)=0.309) and ankle (R(2)=0.210-0.319) energy absorption during the total landing period. These results suggest that biomechanical factors related to anterior cruciate ligament injury are influenced by both the magnitude and timing of lower extremity energy absorption during landing. Copyright © 2010 Elsevier Ltd. All rights reserved.

  12. Effects of Different Footwear Properties and Surface Instability on Neuromuscular Activity and Kinematics During Jumping.

    PubMed

    Lesinski, Melanie; Prieske, Olaf; Borde, Ron; Beurskens, Rainer; Granacher, Urs

    2018-04-13

    Lesinski, M, Prieske, O, Borde, R, Beurskens, R, and Granacher, U. Effects of different footwear properties and surface instability on neuromuscular activity and kinematics during jumping. J Strength Cond Res XX(X): 000-000, 2018-The purpose of this study was to examine sex-specific effects of different footwear properties vs. barefoot condition during the performance of drop jumps (DJs) on stable and unstable surfaces on measures of jump performance, electromyographic (EMG) activity, and knee joint kinematics. Drop jump performance, EMG activity of lower-extremity muscles, as well as sagittal and frontal knee joint kinematics were tested in 28 healthy male (n = 14) and female (n = 14) physically active sports science students (23 ± 2 years) during the performance of DJs on stable and unstable surfaces using different footwear properties (elastic vs. minimal shoes) vs. barefoot condition. Analysis revealed a significantly lower jump height and performance index (Δ7-12%; p < 0.001; 2.22 ≤ d = 2.90) during DJs on unstable compared with stable surfaces. This was accompanied by lower thigh/shank muscle activities (Δ11-28%; p < 0.05; 0.99 ≤ d = 2.16) and knee flexion angles (Δ5-8%; p < 0.05; 1.02 ≤ d = 2.09). Furthermore, knee valgus angles during DJs were significantly lower when wearing shoes compared with barefoot condition (Δ22-32%; p < 0.01; 1.38 ≤ d = 3.31). Sex-specific analyses indicated higher knee flexion angles in females compared with males during DJs, irrespective of the examined surface and footwear conditions (Δ29%; p < 0.05; d = 0.92). Finally, hardly any significant footwear-surface interactions were detected. Our findings revealed that surface instability had an impact on DJ performance, thigh/shank muscle activity, and knee joint kinematics. In addition, the single factors "footwear" and "sex" modulated knee joint kinematics during DJs. However, hardly any significant interaction effects were found. Thus, additional footwear-related effects can be neglected when performing DJs during training on different surfaces.

  13. [Study on the correlation between syndrome differ classification of knee osteoarthritis and X-ray image].

    PubMed

    Jin, Li-Kun; Zhang, Guo-Zhong; Tang, Ke; Liu, Yang

    2010-12-01

    To study the correlation between syndrome differ classification of knee osteoarthritis and X-ray image, so as to provide evidence for clinical diagnosis and treatment. From Jun. 2007 to Dec. 2007, 78 patients (108 knees) with knee osteoarthritis were reviewed, including 65 females (89 knees) and 13 males (19 knees), ranging in age from 41 to 77 years. According to the standards for the differentiation of syndrome in the treatment of knee osteoarthritis defined in Principle of Clinical Research for New Traditional Herbs, the patients were divided into three types: Type I, insufficiency of the liver and kidney, with stagnation of tendons and muscles, 43 knees; Type II, insufficiency of the spleen and kidney, with dampness infusion into bone and joints, 26 knees; Type I, deficiency of the liver and kidney, with inter-obstruction of phlegm and stasis 39 knees. Normotopia and lateral plain film of knee joint of weigh loading and in erect position, and patellofemoral Skyline plain flim was taken. Joint space narrow, osteophyte generation, subchondral osteosclerosis and subchondral cystic degeneration were evaluated. All data were analyzed by K independent samples nonparametric test in order to find out the correlation between syndrome differ classification of knee osteoarthritis and X-ray image. It was shown that after K independent samples nonparametric test about syndrome differ classification of knee osteoarthritis and X-ray image: there were significant differences among three types about lateral patella osteophyte, condyles of tibia osteophyte and Type II was the most serious, Type I was secondary, Type II was the lightest. Other index had no obvious difference among the three groups. There is certain correlation between syndrome differ classification of knee osteoarthritis and X-ray image. There are significant differences among three types about lateral patella osteophyte, condyles of tibia osteophyte, the Type II is the most serious,Type I is secondary, Type II is the lightest. Consequently, it can be deduced that worse osteophyte is one of accordances of Type II-insufficiency of the spleen and kidney, with dampness infusion into bone and joints. And, the Type II is more serious stage in radiologic manifestation.

  14. Cross-cultural adaptation and validation of the Saudi Arabic version of the Knee Injury and Osteoarthritis Outcome Score (KOOS).

    PubMed

    Alfadhel, Saud A; Vennu, Vishal; Alnahdi, Ali H; Omar, Mohammed T; Alasmari, Saeed H; AlJafri, Zahra; Bindawas, Saad M

    2018-06-07

    The Knee Injury Osteoarthritis Outcome Score (KOOS) is a widely used joint-specific measure employed to evaluate pain, symptoms, activities of daily living, recreational activities, and quality of life in patients with knee osteoarthritis (OA). Although the original KOOS has been translated into many languages, a Saudi Arabic version is not available. This study aimed to culturally adapt and evaluate the psychometric properties of the Saudi Arabic version of the KOOS in patients with knee OA. The original KOOS was translated and adapted into Saudi Arabic version over six stages according to the guidelines suggested by Beaton and recommended by the American Association of Orthopedic Surgeons Outcome Committee. Patients diagnosed with knee OA (n = 136) were recruited to examine the psychometric properties, such as internal consistency that was tested using Cronbach's alpha, test-retest reliability that was analyzed using the intra-class correlation coefficient (ICC 2,1 ), and construct validity that examined by testing the correlations between the new version subscales, Form 36 Health Survey subscales, and the Visual Analog Scale, Spearman's correlation coefficient (r s ) was used to measure the correlations. A total of 122 (89.7%) of the 136 participants with knee OA completed the second re-test of new Saudi Arabic version. Excellent internal consistency (Cronbach's alpha = 0.87-0.92) was detected in the subscales of the adapted version, as well as excellent test-retest reliability (ICC 2,1  = 0.92-0.94). The pattern of correlation between the subscales of the Saudi Arabic version of the KOOS, SF-36 domains and the Visual Analog Scale for pain supported the construct validity of the adapted version. The Saudi Arabic version of the KOOS was well accepted and exhibited excellent reliability, internal consistency, and construct validity in Saudi patients with knee OA.

  15. Knee Contact Force Asymmetries in Patients Who Failed Return-to-Sport Readiness Criteria 6 Months After Anterior Cruciate Ligament Reconstruction

    PubMed Central

    Gardinier, Emily S.; Di Stasi, Stephanie; Manal, Kurt; Buchanan, Thomas S.; Snyder-Mackler, Lynn

    2015-01-01

    Background After anterior cruciate ligament (ACL) injury, contact forces are decreased in the injured knee when compared with the uninjured knee. The persistence of contact force asymmetries after ACL reconstruction may increase the risk of reinjury and may play an important role in the development of knee osteoarthritis in these patients. Functional performance may also be useful in identifying patients who demonstrate potentially harmful joint contact force asymmetries after ACL reconstruction. Hypothesis Knee joint contact force asymmetries would be present during gait after ACL reconstruction, and performance on a specific set of validated return-to-sport (RTS) readiness criteria would discriminate between those who demonstrated contact force asymmetries and those who did not. Study Design Descriptive laboratory study. Methods A total of 29 patients with ACL ruptures participated in gait analysis and RTS readiness testing 6 months after reconstruction. Muscle and joint contact forces were estimated using an electromyography (EMG)–driven musculoskeletal model of the knee. The magnitude of typical limb asymmetry in uninjured controls was used to define limits of meaningful limb asymmetry in patients after ACL reconstruction. The RTS testing included isometric quadriceps strength testing, 4 unilateral hop tests, and 2 self-report questionnaires. Paired t tests were used to assess limb symmetry for peak medial and tibiofemoral contact forces in all patients, and a mixed-design analysis of variance was used to analyze the effect of passing or failing RTS testing on contact force asymmetry. Results Among all patients, neither statistically significant nor meaningful contact force asymmetries were identified. However, patients who failed RTS testing exhibited meaningful contact force asymmetries, with tibiofemoral contact force being significantly lower for the involved knee. Conversely, patients who passed RTS testing exhibited neither significant nor meaningful contact force asymmetries. Conclusion Joint contact force asymmetries during gait are present in some patients 6 months after ACL reconstruction. Patients who demonstrated poor functional performance on RTS readiness testing exhibited significant and meaningful contact force asymmetries. Clinical Relevance When assessing all patients together, variability in the functional status obscured significant and meaningful differences in contact force asymmetry in patients 6 months after ACL reconstruction. These specific RTS readiness criteria appear to differentiate between those who demonstrate joint contact force symmetry after ACL reconstruction and those who do not. PMID:25318940

  16. Muscle contributions to knee extension in the early stance phase in patients with knee osteoarthritis.

    PubMed

    Ogaya, Shinya; Kubota, Ryo; Chujo, Yuta; Hirooka, Eiko; Kwang-Ho, Kim; Hase, Kimitaka

    2017-10-01

    The aim of this study was to analyze individual muscle contributions to knee angular acceleration using a musculoskeletal simulation analysis and evaluate knee extension mechanics in the early stance phase in patients with knee osteoarthritis (OA). The subjects comprised 15 patients with medial knee OA and 14 healthy elderly individuals. All participants underwent gait performance test using 8 infrared cameras and two force plates to measure the kinetic and kinematic data. The simulation was driven by 92 Hill-type muscle-tendon units of the lower extremities and a trunk with 23° of freedom. We analyzed each muscle contribution to knee angular acceleration in the 5%-15% and 15%-25% periods of the stance phase (% SP) using an induced acceleration analysis. We compared accelerations by individual muscles between the two groups using an analysis of covariance for controlling gait speed. Patients with knee OA had a significantly lesser knee extension acceleration by the vasti muscles and higher knee acceleration by hip adductors than those in controls in 5-15% SP. In addition, knee OA resulted in significantly lesser knee extension acceleration by the vasti muscles in 15-25% SP. These results indicate that patients with knee OA have decreased dependency on the vasti muscles to control knee movements during early stance phase. Hip adductor muscles, which mainly control mediolateral motion, partly compensate for the weak knee extension by the vasti muscles in patients with knee OA. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Influence of bi- and tri-compartmental knee arthroplasty on the kinematics of the knee joint.

    PubMed

    Wünschel, Markus; Lo, Jiahsuan; Dilger, Torsten; Wülker, Nikolaus; Müller, Otto

    2011-01-27

    The cruciate ligaments are important stabilizers of the knee joint and determine joint kinematics in the natural knee and after cruciate retaining arthroplasty.No in vitro data is available to biomechanically evaluate the ability of the anterior cruciate ligament (ACL) to maintain knee joint kinematics after bicruciate-retaining bi-compartmental knee arthroplasty (BKA).Therefore, the objective of the current study was to investigate the kinematics of the natural knee joint, before and after installing bicruciate-retaining BKA and posterior cruciate retaining total knee arthroplasty. Specifically, we incorporated a dynamic knee simulator to simulate weight-bearing flexions on cadaveric knee specimen before and after surgical manipulations. In this cadaveric study we investigated rotational and translational tibiofemoral kinematics during simulated weight-bearing flexions of the intact knee, after bi-compartmental knee arthroplasty (BKA+), after resecting the ACL in BKA (BKA-), and after posterior cruciate retaining total knee arthroplasty (TKA). Rotation of BKA+ is closest to the intact knee joint, whereas TKA shows significant differences from 30 to 90 degree of flexion. Within the tested flexion range (15 to 90 degree of flexion), there was no significant difference in the anterior-posterior translation among intact, BKA+, and TKA knees. Resecting the ACL in BKA leads to a significant anterior tibial translation. BKA with intact cruciate ligaments resembles rotation and translation of the natural knee during a simulated weight-bearing flexion. It is a suitable treatment option for medial and patellofemoral osteoarthritis with advantages in rotational characteristics compared to TKA.

  18. Effects of prophylactic knee bracing on knee joint kinetics and kinematics during netball specific movements.

    PubMed

    Sinclair, Jonathan K; Vincent, Hayley; Richards, Jim D

    2017-01-01

    To investigate the effects of a prophylactic knee brace on knee joint kinetics and kinematics during netball specific movements. Repeated measures. Laboratory. Twenty university first team level female netball players. Participants performed three movements, run, cut and vertical jump under two conditions (brace and no-brace). 3-D knee joint kinetics and kinematics were measured using an eight-camera motion analysis system. Knee joint kinetics and kinematics were examined using 2 × 3 repeated measures ANOVA whilst the subjective ratings of comfort and stability were investigated using chi-squared tests. The results showed no differences (p > 0.05) in knee joint kinetics. However the internal/external rotation range of motion was significantly (p < 0.05) reduced when wearing the brace in all movements. The subjective ratings of stability revealed that netballers felt that the knee brace improved knee stability in all movements. Further study is required to determine whether reductions in transverse plane knee range of motion serve to attenuate the risk from injury in netballers. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. The utility of plain radiographs in the initial evaluation of knee pain amongst sports medicine patients.

    PubMed

    Alaia, Michael J; Khatib, Omar; Shah, Mehul; A Bosco, Joseph; M Jazrawi, Laith; Strauss, Eric J

    2015-08-01

    To evaluate whether screening radiographs as part of the initial workup of knee pain impacts clinical decision-making in a sports medicine practice. A questionnaire was completed by the attending orthopaedic surgeon following the initial office visit for 499 consecutive patients presenting to the sports medicine centre with a chief complaint of knee pain. The questionnaire documented patient age, duration of symptoms, location of knee pain, associated mechanical symptoms, history of trauma within the past 2 weeks, positive findings on plain radiographs, whether magnetic resonance imaging was ordered, and whether plain radiographs impacted the management decisions for the patient. Patients were excluded if they had prior X-rays, history of malignancy, ongoing pregnancy, constitutional symptoms as well as those patients with prior knee surgery or intra-articular infections. Statistical analyses were then performed to determine which factors were more likely do correspond with diagnostic radiographs. Overall, initial screening radiographs did not change management in 72 % of the patients assessed in the office. The mean age of patients in whom radiographs did change management was 57.9 years compared to 37.1 years in those patients where plain radiograph did not change management (p < 0.0001). Plain radiographs had no impact on clinical management in 97.3 % of patients younger than 40. In patients whom radiographs did change management, radiographs were more likely to influence management if patients were over age forty, had pain for over 6 months, had medial or diffuse pain, or had mechanical symptoms. A basic cost analysis revealed that the cost of a clinically useful radiographic series in a patient under 40 years of age was $7,600, in contrast to $413 for a useful series in patients above the age of 40. Data from the current study support the hypothesis that for the younger patient population, routine radiographic imaging as a screening tool may be of little clinical benefit. Factors supporting obtaining screening radiographs include age greater than 40, knee pain for greater than 6 months, the presence of medial or diffuse knee pain, and the presence of mechanical symptoms. II.

  20. Reduced knee joint loading with lateral and medial wedge insoles for management of knee osteoarthritis: a protocol for a randomized controlled trial.

    PubMed

    Lewinson, Ryan T; Collins, Kelsey H; Vallerand, Isabelle A; Wiley, J Preston; Woodhouse, Linda J; Reimer, Raylene A; Worobets, Jay T; Herzog, Walter; Stefanyshyn, Darren J

    2014-12-03

    Knee osteoarthritis (OA) progression has been linked to increased peak external knee adduction moments (KAMs). Although some trials have attempted to reduce pain and improve function in OA by reducing KAMs with a wedged footwear insole intervention, KAM reduction has not been specifically controlled for in trial designs, potentially explaining the mixed results seen in the literature. Therefore, the primary purpose of this trial is to identify the effects of reduced KAMs on knee OA pain and function. Forty-six patients with radiographically confirmed diagnosis medial knee OA will be recruited for this 3 month randomized controlled trial. Recruitment will be from Alberta and surrounding areas. Eligibility criteria include being between the ages of 40 and 85 years, have knee OA primarily localized to the medial tibiofemoral compartment, based on the American College of Rheumatology diagnostic criteria and be classified as having a Kellgren-Lawrence grade of 1 to 3. Patients will visit the laboratory at baseline for testing that includes dual x-ray absorptiometry, biomechanical testing, and surveys (KOOS, PASE activity scale, UCLA activity scale, comfort visual analog scale). At baseline, patients will be randomized to either a wedged insole group to reduce KAMs, or a waitlist control group where no intervention is provided. The survey tests will be repeated at 3 months, and response to wedged insoles over 3 months will be evaluated. This study represents the first step in systematically evaluating the effects of reduced KAMs on knee OA management by using a patient-specific wedged insole prescription procedure rather than providing the same insole to all patients. The results of this trial will provide indications as to whether reduced KAMs are an effective strategy for knee OA management, and whether a personalized approach to footwear insole prescription is warranted. NCT02067208.

  1. Energy absorption as a predictor of leg impedance in highly trained females.

    PubMed

    Kulas, Anthony S; Schmitz, Randy J; Schultz, Sandra J; Watson, Mary Allen; Perrin, David H

    2006-08-01

    Although leg spring stiffness represents active muscular recruitment of the lower extremity during dynamic tasks such as hopping and running, the joint-specific characteristics comprising the damping portion of this measure, leg impedance, are uncertain. The purpose of this investigation was to assess the relationship between leg impedance and energy absorption at the ankle, knee, and hip during early (impact) and late (stabilization) phases of landing. Twenty highly trained female dancers (age = 20.3 +/- 1.4 years, height = 163.7 +/- 6.0 cm, mass = 62.1 +/- 8.1 kg) were instrumented for biomechanical analysis. Subjects performed three sets of double-leg landings from under preferred, stiff, and soft landing conditions. A stepwise linear regression analysis revealed that ankle and knee energy absorption at impact, and knee and hip energy absorption during the stabilization phases of landing explained 75.5% of the variance in leg impedance. The primary predictor of leg impedance was knee energy absorption during the stabilization phase, independently accounting for 55% of the variance. Future validation studies applying this regression model to other groups of individuals are warranted.

  2. Varus and valgus stress tests after total knee arthroplasty with and without anesthesia.

    PubMed

    Tsukeoka, Tadashi; Tsuneizumi, Yoshikazu

    2016-03-01

    Retrospective studies demonstrated inadequate soft tissue balance is associated with the long-term outcome of total knee arthroplasty (TKA). However, most of these studies have evaluated the joint laxity only postoperatively without anesthesia. Therefore information about the effect of anesthesia on knee laxity is important for soft tissue balancing at the time of surgery. This study was conducted to determine how anesthesia affects the varus and valgus stress tests after TKA. A consecutive series of 26 patients undergoing staged bilateral TKA was evaluated. Varus and valgus laxity of the knee with the TKA implant was measured a few days before the contralateral TKA without anesthesia and again immediately after the contralateral TKA under spinal anesthesia. The laxity was significantly increased from 3.0° to 3.6° (p = 0.005) and from 4.7° to 5.7° (p = 0.007) in medial and lateral side, respectively, when the stress tests were performed under anesthesia in comparison to the laxity measured without anesthesia. The major change in laxity (≥3°) was measured in 6 (23%) patients tested without anesthesia. Anesthesia significantly influenced knee joint laxity after TKA. The findings of this study suggest that muscular forces impart a stabilizing force across the joint.

  3. Comparison of Three Methods of Assessing Muscle Strength and Imbalance Ratios of the Knee

    PubMed Central

    Moss, Crayton L.; Wright, P. Thomas

    1993-01-01

    Three strength measurement methods for determining muscle strength and imbalance ratios of the knee were compared in 41 (23 female, 18 male) NCAA Division I track and field athletes. Peak quadriceps extensions and hamstring flexions were measured isotonically, isometrically, and isokinetically. Isokinetic measurements were performed on a Cybex II at 60°/s. Isometric extension and flexion measurements were performed using the Nicholas Manual Muscle Tester (Lafayette Instruments; Lafayette, Ind). Isotonic measurements were done on both Universal and Nautilus apparatuses. Testing order was randomized to avoid a treatment order effect. A repeated measures ANOVA and a post hoc Tukey test were used to compare the three methods of assessing strength and imbalance ratios of the knee. Absolute strength values were significantly different according to gender and mode of testing. Bilateral strength imbalance ratios for knee flexion were significantly lower for the Nautilus leg curl machine. Ipsilateral strength imbalance ratios were significantly greater for the Cybex II. Our results indicated that absolute strength values cannot be interchanged between testing modes. Except for Cybex II (ipsilateral) and Nautilus (bilateral knee flexion), strength imbalance ratios could be interchanged. ImagesFig 1.Fig 2.Fig 3.Fig 4.Fig 5.Fig 6.Fig 7.INGING PMID:16558207

  4. Instruction and jump-landing kinematics in college-aged female athletes over time.

    PubMed

    Etnoyer, Jena; Cortes, Nelson; Ringleb, Stacie I; Van Lunen, Bonnie L; Onate, James A

    2013-01-01

    Instruction can be used to alter the biomechanical movement patterns associated with anterior cruciate ligament (ACL) injuries. To determine the effects of instruction through combination (self and expert) feedback or self-feedback on lower extremity kinematics during the box-drop-jump task, running-stop-jump task, and sidestep-cutting maneuver over time in college-aged female athletes. Randomized controlled clinical trial. Laboratory. Forty-three physically active women (age = 21.47 ± 1.55 years, height = 1.65 ± 0.08 m, mass = 63.78 ± 12.00 kg) with no history of ACL or lower extremity injuries or surgery in the 2 months before the study were assigned randomly to 3 groups: self-feedback (SE), combination feedback (CB), or control (CT). Participants performed a box-drop-jump task for the pretest and then received feedback about their landing mechanics. After the intervention, they performed an immediate posttest of the box-drop-jump task and a running-stop-jump transfer test. Participants returned 1 month later for a retention test of each task and a sidestep-cutting maneuver. Kinematic data were collected with an 8-camera system sampled at 500 Hz. The independent variables were feedback group (3), test time (3), and task (3). The dependent variables were knee- and hip-flexion, knee-valgus, and hip- abduction kinematics at initial contact and at peak knee flexion. For the box-drop-jump task, knee- and hip-flexion angles at initial contact were greater at the posttest than at the retention test (P < .001). At peak knee flexion, hip flexion was greater at the posttest than at the pretest (P = .003) and was greater at the retention test than at the pretest (P = .04); knee valgus was greater at the retention test than at the pretest (P = .03) and posttest (P = .02). Peak knee flexion was greater for the CB than the SE group (P = .03) during the box-drop-jump task at posttest. For the running-stop-jump task at the posttest, the CB group had greater peak knee flexion than the SE and CT (P ≤ .05). Our results suggest that feedback involving a combination of self-feedback and expert video feedback with oral instruction effectively improved lower extremity kinematics during jump-landing tasks.

  5. Instruction and Jump-Landing Kinematics in College-Aged Female Athletes Over Time

    PubMed Central

    Etnoyer, Jena; Cortes, Nelson; Ringleb, Stacie I.; Van Lunen, Bonnie L.; Onate, James A.

    2013-01-01

    Context: Instruction can be used to alter the biomechanical movement patterns associated with anterior cruciate ligament (ACL) injuries. Objective: To determine the effects of instruction through combination (self and expert) feedback or self-feedback on lower extremity kinematics during the box–drop-jump task, running–stop-jump task, and sidestep-cutting maneuver over time in college-aged female athletes. Design: Randomized controlled clinical trial. Setting: Laboratory. Patients or Other Participants: Forty-three physically active women (age = 21.47 ± 1.55 years, height = 1.65 ± 0.08 m, mass = 63.78 ± 12.00 kg) with no history of ACL or lower extremity injuries or surgery in the 2 months before the study were assigned randomly to 3 groups: self-feedback (SE), combination feedback (CB), or control (CT). Intervention(s): Participants performed a box–drop-jump task for the pretest and then received feedback about their landing mechanics. After the intervention, they performed an immediate posttest of the box–drop-jump task and a running–stop-jump transfer test. Participants returned 1 month later for a retention test of each task and a sidestep-cutting maneuver. Kinematic data were collected with an 8-camera system sampled at 500 Hz. Main Outcome Measure(s): The independent variables were feedback group (3), test time (3), and task (3). The dependent variables were knee- and hip-flexion, knee-valgus, and hip- abduction kinematics at initial contact and at peak knee flexion. Results: For the box–drop-jump task, knee- and hip-flexion angles at initial contact were greater at the posttest than at the retention test (P < .001). At peak knee flexion, hip flexion was greater at the posttest than at the pretest (P = .003) and was greater at the retention test than at the pretest (P = .04); knee valgus was greater at the retention test than at the pretest (P = .03) and posttest (P = .02). Peak knee flexion was greater for the CB than the SE group (P = .03) during the box–drop-jump task at posttest. For the running–stop-jump task at the posttest, the CB group had greater peak knee flexion than the SE and CT (P ≤ .05). Conclusions: Our results suggest that feedback involving a combination of self-feedback and expert video feedback with oral instruction effectively improved lower extremity kinematics during jump-landing tasks. PMID:23672380

  6. A Novel Two-Velocity Method for Elaborate Isokinetic Testing of Knee Extensors.

    PubMed

    Grbic, Vladimir; Djuric, Sasa; Knezevic, Olivera M; Mirkov, Dragan M; Nedeljkovic, Aleksandar; Jaric, Slobodan

    2017-09-01

    Single outcomes of standard isokinetic dynamometry tests do not discern between various muscle mechanical capacities. In this study, we aimed to (1) evaluate the shape and strength of the force-velocity relationship of knee extensors, as observed in isokinetic tests conducted at a wide range of angular velocities, and (2) explore the concurrent validity of a simple 2-velocity method. Thirteen physically active females were tested for both the peak and averaged knee extensor concentric force exerted at the angular velocities of 30°-240°/s recorded in the 90°-170° range of knee extension. The results revealed strong (0.960

  7. Effect of ACL graft material on anterior knee force during simulated in vivo ovine motion applied to the porcine knee: An in vitro examination of force during 2000 cycles.

    PubMed

    Boguszewski, Daniel V; Wagner, Christopher T; Butler, David L; Shearn, Jason T

    2015-12-01

    This study determined how anterior cruciate ligament (ACL) reconstruction affected the magnitude and temporal patterns of anterior knee force and internal knee moment during 2000 cycles of simulated gait. Porcine knees were tested using a six degree-of-freedom robot, examining three porcine allograft materials compared with the native ACL. Reconstructions were performed using: (1) bone-patellar tendon-bone allograft (BPTB), (2) reconstructive porcine tissue matrix (RTM), or (3) an RTM-polymer hybrid construct (Hybrid). Forces and moments were measured over the entire gait cycle and contrasted at heel strike, mid stance, toe off, and peak flexion. The Hybrid construct performed the best, as magnitude and temporal changes in both anterior knee force and internal knee moment were not different from the native ACL knee. Conversely, the RTM knees showed greater loss in anterior knee force during 2000 cycles than the native ACL knee at heel strike and toe off, with an average force loss of 46%. BPTB knees performed the least favorably, with significant loss in anterior knee force at all key points and an average force loss of 61%. This is clinically relevant, as increases in post-operative knee laxity are believed to play a role in graft failure and early onset osteoarthritis. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  8. The effect of a knee ankle foot orthosis incorporating an active knee mechanism on gait of a person with poliomyelitis.

    PubMed

    Arazpour, Mokhtar; Chitsazan, Ahmad; Bani, Monireh Ahmadi; Rouhi, Gholamreza; Ghomshe, Farhad Tabatabai; Hutchins, Stephen W

    2013-10-01

    The aim of this case study was to identify the effect of a powered stance control knee ankle foot orthosis on the kinematics and temporospatial parameters of walking by a person with poliomyelitis when compared to a knee ankle foot orthosis. A knee ankle foot orthosis was initially manufactured by incorporating drop lock knee joints and custom molded ankle foot orthoses and fitted to a person with poliomyelitis. The orthosis was then adapted by adding electrically activated powered knee joints to provide knee extension torque during stance and also flexion torque in swing phase. Lower limb kinematic and kinetic data plus data for temporospatial parameters were acquired from three test walks using each orthosis. Walking speed, step length, and vertical and horizontal displacement of the pelvis decreased when walking with the powered stance control knee ankle foot orthosis compared to the knee ankle foot orthosis. When using the powered stance control knee ankle foot orthosis, the knee flexion achieved during swing and also the overall pattern of walking more closely matched that of normal human walking. The reduced walking speed may have caused the smaller compensatory motions detected when the powered stance control knee ankle foot orthosis was used. The new powered SCKAFO facilitated controlled knee flexion and extension during ambulation for a volunteer poliomyelitis person.

  9. Risk Factors for Knee Injury in Golf: A Systematic Review.

    PubMed

    Baker, Matthew L; Epari, Devakar R; Lorenzetti, Silvio; Sayers, Mark; Boutellier, Urs; Taylor, William R

    2017-12-01

    Golf is commonly considered a low-impact sport that carries little risk of injury to the knee and is generally allowed following total knee arthroplasty (TKA). Kinematic and kinetic studies of the golf swing have reported results relevant to the knee, but consensus as to the loads experienced during a swing and how the biomechanics of an individual's technique may expose the knee to risk of injury is lacking. Our objective was to establish (1) the prevalence of knee injury resulting from participation in golf and (2) the risk factors for knee injury from a biomechanical perspective, based on an improved understanding of the internal loading conditions and kinematics that occur in the knee from the time of addressing the ball to the end of the follow-through. A systematic literature search was conducted to determine the injury rate, kinematic patterns, loading, and muscle activity of the knee during golf. A knee injury prevalence of 3-18% was established among both professional and amateur players, with no clear dependence on skill level or sex; however, older players appear at greater risk of injury. Studies reporting kinematics indicate that the lead knee is exposed to a complex series of motions involving rapid extension and large magnitudes of tibial internal rotation, conditions that may pose risks to the structures of a natural knee or TKA. To date, the loads experienced by the lead knee during a golf swing have been reported inconsistently in the literature. Compressive loads ranging from 100 to 440% bodyweight have been calculated and measured using methods including inverse dynamics analysis and instrumented knee implants. Additionally, the magnitude of loading appears to be independent of the club used. This review is the first to highlight the lack of consensus regarding knee loading during the golf swing and the associated risks of injury. Results from the literature suggest the lead knee is subject to a higher magnitude of stress and more demanding motions than the trail knee. Therefore, recommendations regarding return to golf following knee injury or surgical intervention should carefully consider the laterality of the injury.

  10. The influence of a powered knee-ankle-foot orthosis on walking in poliomyelitis subjects: A pilot study.

    PubMed

    Arazpour, Mokhtar; Moradi, Alireza; Samadian, Mohammad; Bahramizadeh, Mahmood; Joghtaei, Mahmoud; Ahmadi Bani, Monireh; Hutchins, Stephen W; Mardani, Mohammad A

    2016-06-01

    Traditionally, the anatomical knee joint is locked in extension when walking with a conventional knee-ankle-foot orthosis. A powered knee-ankle-foot orthosis was developed to provide restriction of knee flexion during stance phase and active flexion and extension of the knee during swing phase of gait. The purpose of this study was to determine differences of the powered knee-ankle-foot orthosis compared to a locked knee-ankle-foot orthosis in kinematic data and temporospatial parameters during ambulation. Quasi-experimental design. Subjects with poliomyelitis (n = 7) volunteered for this study and undertook gait analysis with both the powered and the conventional knee-ankle-foot orthoses. Three trials per orthosis were collected while each subject walked along a 6-m walkway using a calibrated six-camera three-dimensional video-based motion analysis system. Walking with the powered knee-ankle-foot orthosis resulted in a significant reduction in both walking speed and step length (both 18%), but a significant increase in stance phase percentage compared to walking with the conventional knee-ankle-foot orthosis. Cadence was not significantly different between the two test conditions (p = 0.751). There was significantly higher knee flexion during swing phase and increased hip hiking when using the powered orthosis. The new powered orthosis permitted improved knee joint kinematic for knee-ankle-foot orthosis users while providing knee support in stance and active knee motion in swing in the gait cycle. Therefore, the new powered orthosis provided more natural knee flexion during swing for orthosis users compared to the locked knee-ankle-foot orthosis. This orthosis has the potential to improve knee joint kinematics and gait pattern in poliomyelitis subjects during walking activities. © The International Society for Prosthetics and Orthotics 2015.

  11. Target of physiological gait: Realization of speed adaptive control for a prosthetic knee during swing flexion.

    PubMed

    Cao, Wujing; Yu, Hongliu; Zhao, Weiliang; Li, Jin; Wei, Xiaodong

    2018-01-01

    Prosthetic knee is the most important component of lower limb prosthesis. Speed adaptive for prosthetic knee during swing flexion is the key method to realize physiological gait. This study aims to discuss the target of physiological gait, propose a speed adaptive control method during swing flexion and research the damping adjustment law of intelligent hydraulic prosthetic knee. According to the physiological gait trials of healthy people, the control target during swing flexion is defined. A new prosthetic knee with fuzzy logical control during swing flexion is designed to realize the damping adjustment automatically. The function simulation and evaluation system of intelligent knee prosthesis is provided. Speed adaptive control test of the intelligent prosthetic knee in different velocities are researched. The maximum swing flexion of the knee angle is set between sixty degree and seventy degree as the target of physiological gait. Preliminary experimental results demonstrate that the prosthetic knee with fuzzy logical control is able to realize physiological gait under different speeds. The faster the walking, the bigger the valve closure percentage of the hydraulic prosthetic knee. The proposed fuzzy logical control strategy and intelligent hydraulic prosthetic knee are effective for the amputee to achieve physiological gait.

  12. Novel method of using dynamic electrical impedance signals for noninvasive diagnosis of knee osteoarthritis.

    PubMed

    Gajre, Suhas S; Anand, Sneh; Singh, U; Saxena, Rajendra K

    2006-01-01

    Osteoarthritis (OA) of knee is the most commonly occurring non-fatal irreversible disease, mainly in the elderly population and particularly in female. Various invasive and non-invasive methods are reported for the diagnosis of this articular cartilage pathology. Well known techniques such as X-ray, computed tomography, magnetic resonance imaging, arthroscopy and arthrography are having their disadvantages, and diagnosis of OA in early stages with simple effective noninvasive method is still a biomedical engineering problem. Analyzing knee joint noninvasive signals around knee might give simple solution for diagnosis of knee OA. We used electrical impedance data from knees to compare normal and osteoarthritic subjects during the most common dynamic conditions of the knee, i.e. walking and knee swing. It was found that there is substantial difference in the properties of the walking cycle (WC) and knee swing cycle (KS) signals. In experiments on 90 pathological (combined for KS and WC signals) and 72 normal signals (combined), suitable features were drawn. Then signals were used to classify as normal or pathological. Artificial multilayer feed forward neural network was trained using back propagation algorithm for the classification. On a training data set of 54 signals for KS signals, the classification efficiency for a test set of 54 was 70.37% and 85.19% with and without normalization respectively wrt base impedance. Similarly, the training set of 27 WC signals and test set of 27 signals resulted in 77.78% and 66.67% classification efficiency. The results indicate that dynamic electrical impedance signals have potential to be used as a novel method for noninvasive diagnosis of knee OA.

  13. Do Independent Sector Treatment Centres (ISTC) impact on specialist registrar training in primary hip and knee arthroplasty?

    PubMed

    Clamp, Jonathan A; Baiju, Dean; Copas, David P; Hutchinson, James W; Rowles, John M

    2008-09-01

    The introduction of Modernising Medical Careers (MMC) is likely to reduce specialist registrar (SpR) operative experience during higher surgical training (HST). A further negative impact on training by local Independent Sector Treatment Centres (ISTCs) could reduce experience, and thus competence, in primary joint arthroplasty at completion of higher surgical training. Retrospective case note and radiograph analysis of patients receiving primary hip and knee arthroplasty in a teaching hospital, before and after the establishment of a local ISTC. Patients and operative details were recorded from the selected case notes. Corresponding radiographs were assessed and the severity of the disease process assessed. Fewer primary hip and knee replacements were performed by SpRs in the time period after the establishment of an ISTC. ISTCs may adversely affect SpR training in primary joint arthroplasty.

  14. A mathematical model of forces in the knee under isometric quadriceps contractions.

    PubMed

    Huss, R A; Holstein, H; O'Connor, J J

    2000-02-01

    To predict the knee's response to isometric quadriceps contractions against a fixed tibial restraint.Design. Mathematical modelling of the human knee joint. Isometric quadriceps contraction is commonly used for leg muscle strengthening following ligament injury or reconstruction. It is desirable to know the ligament forces induced but direct measurement is difficult. The model, previously applied to the Lachmann or 'drawer' tests, combines an extensible fibre-array representation of the cruciate ligaments with a compressible 'thin-layer' representation of the cartilage. The model allows the knee configuration and force system to be calculated, given flexion angle, restraint position and loading. Inclusion of cartilage deformation increases relative tibio-femoral translation and decreases the ligament forces generated. For each restraint position, a range of flexion angles is found in which no ligament force is required, as opposed to a single flexion angle in the case of incompressible cartilage layers. Knee geometry and ligament elasticity are found to be the most important factors governing the joint's response to isometric quadriceps contractions, but cartilage deformation is found to be more important than in the Lachmann test. Estimation of knee ligament forces is important when devising exercise regimes following ligament injury or reconstruction. The finding of a 'neutral zone' of zero ligament force may have implications for rehabilitation of the ligament-injured knee.

  15. Development of estimation system of knee extension strength using image features in ultrasound images of rectus femoris

    NASA Astrophysics Data System (ADS)

    Murakami, Hiroki; Watanabe, Tsuneo; Fukuoka, Daisuke; Terabayashi, Nobuo; Hara, Takeshi; Muramatsu, Chisako; Fujita, Hiroshi

    2016-04-01

    The word "Locomotive syndrome" has been proposed to describe the state of requiring care by musculoskeletal disorders and its high-risk condition. Reduction of the knee extension strength is cited as one of the risk factors, and the accurate measurement of the strength is needed for the evaluation. The measurement of knee extension strength using a dynamometer is one of the most direct and quantitative methods. This study aims to develop a system for measuring the knee extension strength using the ultrasound images of the rectus femoris muscles obtained with non-invasive ultrasonic diagnostic equipment. First, we extract the muscle area from the ultrasound images and determine the image features, such as the thickness of the muscle. We combine these features and physical features, such as the patient's height, and build a regression model of the knee extension strength from training data. We have developed a system for estimating the knee extension strength by applying the regression model to the features obtained from test data. Using the test data of 168 cases, correlation coefficient value between the measured values and estimated values was 0.82. This result suggests that this system can estimate knee extension strength with high accuracy.

  16. Translation and Validation of the Knee Society Score - KSS for Brazilian Portuguese

    PubMed Central

    Silva, Adriana Lucia Pastore e; Demange, Marco Kawamura; Gobbi, Riccardo Gomes; da Silva, Tânia Fernanda Cardoso; Pécora, José Ricardo; Croci, Alberto Tesconi

    2012-01-01

    Objective To translate, culturally adapt and validate the "Knee Society Score"(KSS) for the Portuguese language and determine its measurement properties, reproducibility and validity. Methods We analyzed 70 patients of both sexes, aged between 55 and 85 years, in a cross-sectional clinical trial, with diagnosis of primary osteoarthritis ,undergoing total knee arthroplasty surgery. We assessed the patients with the English version of the KSS questionnaire and after 30 minutes with the Portuguese version of the KSS questionnaire, done by a different evaluator. All the patients were assessed preoperatively, and again at three, and six months postoperatively. Results There was no statistical difference, using Cronbach's alpha index and the Bland-Altman graphical analysis, for the knees core during the preoperative period (p =1), and at three months (p =0.991) and six months postoperatively (p =0.985). There was no statistical difference for knee function score for all three periods (p =1.0). Conclusion The Brazilian version of the Knee Society Score is easy to apply, as well providing as a valid and reliable instrument for measuring the knee score and function of Brazilian patients undergoing TKA. Level of Evidence: Level I - Diagnostic Studies- Investigating a Diagnostic Test- Testing of previously developed diagnostic criteria on consecutive patients (with universally applied 'gold' reference standard). PMID:24453576

  17. Assessment of Knee Proprioception in the Anterior Cruciate Ligament Injury Risk Position in Healthy Subjects: A Cross-sectional Study.

    PubMed

    Mir, Seyed Mohsen; Talebian, Saeed; Naseri, Nasrin; Hadian, Mohammad-Reza

    2014-10-01

    [Purpose] Knee joint proprioception combines sensory input from a variety of afferent receptors that encompasses the sensations of joint position and motion. Poor proprioception is one of the risk factors of anterior cruciate ligament injury. Most studies have favored testing knee joint position sense in the sagittal plane and non-weight-bearing position. One of the most common mechanisms of noncontact anterior cruciate ligament injury is dynamic knee valgus. No study has measured joint position sense in a manner relevant to the mechanism of injury. Therefore, the aim of this study was to measure knee joint position sense in the noncontact anterior cruciate ligament injury risk position and normal condition. [Subjects and Methods] Thirty healthy male athletes participated in the study. Joint position sense was evaluated by active reproduction of the anterior cruciate ligament injury risk position and normal condition. The dominant knees of subjects were tested. [Results] The results showed less accurate knee joint position sense in the noncontact anterior cruciate ligament injury risk position rather than the normal condition. [Conclusion] The poorer joint position sense in non-contact anterior cruciate ligament injury risk position compared with the normal condition may contribute to the increased incidence of anterior cruciate ligament injury.

  18. Association between frontal plane knee control and lower extremity injuries: a prospective study on young team sport athletes

    PubMed Central

    Pasanen, Kati; Krosshaug, Tron; Vasankari, Tommi; Kannus, Pekka; Heinonen, Ari; Kujala, Urho M; Avela, Janne; Perttunen, Jarmo; Parkkari, Jari

    2018-01-01

    Background/aim Poor frontal plane knee control can manifest as increased dynamic knee valgus during athletic tasks. The purpose of this study was to investigate the association between frontal plane knee control and the risk of acute lower extremity injuries. In addition, we wanted to study if the single-leg squat (SLS) test can be used as a screening tool to identify athletes with an increased injury risk. Methods A total of 306 basketball and floorball players participated in the baseline SLS test and a 12-month injury registration follow-up. Acute lower extremity time-loss injuries were registered. Frontal plane knee projection angles (FPKPA) during the SLS were calculated using a two-dimensional video analysis. Results Athletes displaying a high FPKPA were 2.7 times more likely to sustain a lower extremity injury (adjusted OR 2.67, 95% CI 1.23 to 5.83) and 2.4 times more likely to sustain an ankle injury (OR 2.37, 95% CI 1.13 to 4.98). There was no statistically significant association between FPKPA and knee injury (OR 1.49, 95% CI 0.56 to 3.98). The receiver operating characteristic curve analyses indicated poor combined sensitivity and specificity when FPKPA was used as a screening test for lower extremity injuries (area under the curve of 0.59) and ankle injuries (area under the curve of 0.58). Conclusions Athletes displaying a large FPKPA in the SLS test had an elevated risk of acute lower extremity and ankle injuries. However, the SLS test is not sensitive and specific enough to be used as a screening tool for future injury risk. PMID:29387448

  19. MR appearance of autologous chondrocyte implantation in the knee: correlation with the knee features and clinical outcome.

    PubMed

    Takahashi, Tomoki; Tins, Bernhard; McCall, Iain W; Richardson, James B; Takagi, Katsumasa; Ashton, Karen

    2006-01-01

    To relate the magnetic resonance imaging (MRI) appearance of autologous chondrocyte implantation (ACI) in the knee in the 1st postoperative year with other knee features on MRI and with clinical outcome. Forty-nine examinations were performed in 49 patients at 1 year after ACI in the knee. Forty-one preoperative magnetic resonance (MR) examinations were also available. The grafts were assessed for smoothness, thickness in comparison with that of adjacent cartilage, signal intensity, integration to underlying bone and adjacent cartilage, and congruity of subchondral bone. Presence of overgrowth and bone marrow appearance beneath the graft were also assessed. Presence of osteophyte formation, further cartilage defects, appearance of the cruciate ligaments and the menisci were also recorded. An overall graft score was constructed, using the graft appearances. This was correlated with the knee features and the Lysholm score, a clinical self-assessment score. The data were analysed by a Kruskal-Wallis H test followed by a Mann-Whitney U test with Bonferroni correction as post-hoc test. Of 49 grafts, 32 (65%) demonstrated complete defect filling 1 year postoperatively. General overgrowth was seen in eight grafts (16%), and partial overgrowth in 13 grafts (26%). Bone marrow change underneath the graft was seen; oedema was seen in 23 grafts (47%), cysts in six grafts (12%) and sclerosis in two grafts (4%). Mean graft score was 8.7 (of maximal 12) (95% CI 8.0-9.5). Knees without osteophyte formation or additional other cartilage defects (other than the graft site) had a significantly higher graft score than knees with multiple osteophytes (P=0.0057) or multiple further cartilage defects (P=0.014). At 1 year follow-up improvement in the clinical scores was not significantly different for any subgroup. Knees with a graft score of 8 points or greater had a better improvement of the clinical score than those of 7 points or fewer. At 1 year follow-up after ACI, higher graft scores are associated with an overall better preserved knee joint. ACI improves the clinical outcome, but there is no statistically significant correlation of graft score and clinical outcome.

  20. Computer-assisted surgery simulations and directed practice of total knee arthroplasty: educational benefits to the trainee.

    PubMed

    Myden, C A; Anglin, C; Kopp, G D; Hutchison, C R

    2012-01-01

    Orthopaedic residents typically learn to perform total knee arthroplasty (TKA) through an apprenticeship-type model, which is a necessarily slow process. Surgical skills courses, using artificial bones, have been shown to improve technical and cognitive skills significantly within a couple of days. The addition of computer-assisted surgery (CAS) simulations challenges the participants to consider the same task in a different context, promoting cognitive flexibility. We designed a hands-on educational intervention for junior residents with a conventional tibiofemoral TKA station, two different tibiofemoral CAS stations, and a CAS and conventional patellar resection station, including both qualitative and quantitative analyses. Qualitatively, structured interviews before and after the course were analyzed for recurring themes. Quantitatively, subjects were evaluated on their technical skills before and after the course, and on a multiple-choice knowledge test and error detection test after the course, in comparison to senior residents who performed only the testing. Four themes emerged: confidence, awareness, deepening knowledge and changed perspectives. The residents' attitudes to CAS changed from negative before the course to neutral or positive afterwards. The junior resident group completed 23% of tasks in the pre-course skills test and 75% of tasks on the post-test (p<0.01), compared to 45% of tasks completed by the senior resident group. High-impact educational interventions, promoting cognitive flexibility, would benefit trainees, attending surgeons, the healthcare system and patients.

  1. Difference in knee rotation between total and unicompartmental knee arthroplasties during stair climbing.

    PubMed

    Jung, Myung-Chul; Chung, Jun Young; Son, Kwang-Hyun; Wang, Hui; Hwang, Jaejin; Kim, Jay Joong; Kim, Joon Ho; Min, Byoung-Hyun

    2014-08-01

    The purpose of this study was to compare knee kinematics during stair walking in patients with simultaneous total knee arthroplasty (TKA) and unicompartmental knee arthroplasties (UKA). It was hypothesized that UKA would reproduce more normalized knee kinematics than TKA during stair ascent and descent. Six patients who received UKA in one knee and TKA in the other knee were included in the study. For this study, a four-step staircase was assembled with two force platforms being positioned at the centre of the second and third steps. Each patient was attached with 16 reflective markers at both lower extremities and was asked to perform five roundtrip trials of stair climbing. Kinematic parameters including stance duration, knee angle, vertical ground reaction force (GRF), joint reaction force, and moments were obtained and analysed using a10-camera motion system (VICON, Oxford, UK). Nonparametric Friedman test was used to compare the results between two arthroplasty methods and between stair ascent and descent. Compared to TKA, UKA knees exhibited significantly greater degree of rotation in transverse planes (5.0 degrees during ascent and 6.0 degrees during descent on average), but showed no difference in terms of the other parameters. When comparing the results during stair ascent with descent, overall greater knee angle, vertical GRF, joint reaction force, and moment were observed during stair descent. Both UKA and TKA knees have shown overall similar knee kinematics, though UKA knee may allow greater degree of rotation freedom, which resembles normal knee kinematics during stair walking.

  2. Cartilage Injuries in the Adult Knee

    PubMed Central

    Moyad, Thomas F.

    2011-01-01

    Cartilage injuries are frequently recognized as a source of significant morbidity and pain in patients with previous knee injuries. The majority of patients who undergo routine knee arthroscopy have evidence of a chondral defect. These injuries represent a continuum of pathology from small, asymptomatic lesions to large, disabling defects affecting a major portion of one or more compartments within the knee joint. In comparison to patients with osteoarthritis, individuals with isolated chondral surface damage are often younger, significantly more active, and usually less willing to accept limitations in activities that require higher impact. At the present time, a variety of surgical procedures exist, each with their unique indications. This heterogeneity of treatment options frequently leads to uncertainty regarding which techniques, if any, are most appropriate for patients. The purpose of this review is to describe the workup and discuss the management techniques for cartilage injuries within the adult knee. PMID:26069581

  3. The influence of sex and maturation on landing biomechanics: implications for anterior cruciate ligament injury.

    PubMed

    Sigward, S M; Pollard, C D; Powers, C M

    2012-08-01

    During landing and cutting, females exhibit greater frontal plane moments at the knee (internal knee adductor moments or external knee abduction moments) and favor the use of the knee extensors over the hip extensors to attenuate impact forces when compared with males. However, it is not known when this biomechanical profile emerges. The purpose of this study was to compare landing biomechanics between sexes across maturation levels. One hundred and nineteen male and female soccer players (9-22 years) participated. Subjects were grouped based on maturational development. Lower extremity kinematics and kinetics were obtained during a drop-land task. Dependent variables included the average internal knee adductor moment and sagittal plane knee/hip moment and energy absorption ratios during the deceleration phase of landing. When averaged across maturation levels, females demonstrated greater internal knee adductor moments (0.06±0.03 vs 0.01±0.02 N m/kg m; P<0.005), knee/hip extensor moment ratios (2.0±0.1 vs 1.4±0.1 N m/kg m; P<0.001) and knee/hip energy absorption ratios (2.9±0.1 vs 1.96±0.1 N m/kg m; P<0.001) compared with males. Higher knee adductor moments combined with disproportionate use of knee extensors relative to hip extensors observed in females reflect a biomechanical pattern that increases anterior cruciate ligament loading. This biomechanical strategy already was established in pre-pubertal female athletes. © 2011 John Wiley & Sons A/S.

  4. Is digital photography an accurate and precise method for measuring range of motion of the hip and knee?

    PubMed

    Russo, Russell R; Burn, Matthew B; Ismaily, Sabir K; Gerrie, Brayden J; Han, Shuyang; Alexander, Jerry; Lenherr, Christopher; Noble, Philip C; Harris, Joshua D; McCulloch, Patrick C

    2017-09-07

    Accurate measurements of knee and hip motion are required for management of musculoskeletal pathology. The purpose of this investigation was to compare three techniques for measuring motion at the hip and knee. The authors hypothesized that digital photography would be equivalent in accuracy and show higher precision compared to the other two techniques. Using infrared motion capture analysis as the reference standard, hip flexion/abduction/internal rotation/external rotation and knee flexion/extension were measured using visual estimation, goniometry, and photography on 10 fresh frozen cadavers. These measurements were performed by three physical therapists and three orthopaedic surgeons. Accuracy was defined by the difference from the reference standard, while precision was defined by the proportion of measurements within either 5° or 10°. Analysis of variance (ANOVA), t-tests, and chi-squared tests were used. Although two statistically significant differences were found in measurement accuracy between the three techniques, neither of these differences met clinical significance (difference of 1.4° for hip abduction and 1.7° for the knee extension). Precision of measurements was significantly higher for digital photography than: (i) visual estimation for hip abduction and knee extension, and (ii) goniometry for knee extension only. There was no clinically significant difference in measurement accuracy between the three techniques for hip and knee motion. Digital photography only showed higher precision for two joint motions (hip abduction and knee extension). Overall digital photography shows equivalent accuracy and near-equivalent precision to visual estimation and goniometry.

  5. Joint Mobilization Enhances Mechanisms of Conditioned Pain Modulation in Individuals With Osteoarthritis of the Knee.

    PubMed

    Courtney, Carol A; Steffen, Alana D; Fernández-de-Las-Peñas, César; Kim, John; Chmell, Samuel J

    2016-03-01

    An experimental laboratory study with a repeated-measures crossover design. Treatment effects of joint mobilization may occur in part by decreasing excitability of central nociceptive pathways. Impaired conditioned pain modulation (CPM) has been found experimentally in persons with knee and hip osteoarthritis, indicating impaired inhibition of central nociceptive pathways. We hypothesized increased effectiveness of CPM following application of joint mobilization, determined via measures of deep tissue hyperalgesia. To examine the effect of joint mobilization on impaired CPM. An examination of 40 individuals with moderate/severe knee osteoarthritis identified 29 (73%) with impaired CPM. The subjects were randomized to receive 6 minutes of knee joint mobilization (intervention) or manual cutaneous input only, 1 week apart. Deep tissue hyperalgesia was examined via pressure pain thresholds bilaterally at the knee medial joint line and the hand at baseline, postintervention, and post-CPM testing. Further, vibration perception threshold was measured at the medial knee epicondyle at baseline and post-CPM testing. Joint mobilization, but not cutaneous input intervention, resulted in a global increase in pressure pain threshold, indicated by diminished hyperalgesic responses to pressure stimulus. Further, CPM was significantly enhanced following joint mobilization. Diminished baseline vibration perception threshold acuity was enhanced following joint mobilization at the knee that received intervention, but not at the contralateral knee. Resting pain was also significantly lower following the joint intervention. Conditioned pain modulation was enhanced following joint mobilization, demonstrated by a global decrease in deep tissue pressure sensitivity. Joint mobilization may act via enhancement of descending pain mechanisms in patients with painful knee osteoarthritis.

  6. A Combined Experimental and Computational Approach to Subject-Specific Analysis of Knee Joint Laxity

    PubMed Central

    Harris, Michael D.; Cyr, Adam J.; Ali, Azhar A.; Fitzpatrick, Clare K.; Rullkoetter, Paul J.; Maletsky, Lorin P.; Shelburne, Kevin B.

    2016-01-01

    Modeling complex knee biomechanics is a continual challenge, which has resulted in many models of varying levels of quality, complexity, and validation. Beyond modeling healthy knees, accurately mimicking pathologic knee mechanics, such as after cruciate rupture or meniscectomy, is difficult. Experimental tests of knee laxity can provide important information about ligament engagement and overall contributions to knee stability for development of subject-specific models to accurately simulate knee motion and loading. Our objective was to provide combined experimental tests and finite-element (FE) models of natural knee laxity that are subject-specific, have one-to-one experiment to model calibration, simulate ligament engagement in agreement with literature, and are adaptable for a variety of biomechanical investigations (e.g., cartilage contact, ligament strain, in vivo kinematics). Calibration involved perturbing ligament stiffness, initial ligament strain, and attachment location until model-predicted kinematics and ligament engagement matched experimental reports. Errors between model-predicted and experimental kinematics averaged <2 deg during varus–valgus (VV) rotations, <6 deg during internal–external (IE) rotations, and <3 mm of translation during anterior–posterior (AP) displacements. Engagement of the individual ligaments agreed with literature descriptions. These results demonstrate the ability of our constraint models to be customized for multiple individuals and simultaneously call attention to the need to verify that ligament engagement is in good general agreement with literature. To facilitate further investigations of subject-specific or population based knee joint biomechanics, data collected during the experimental and modeling phases of this study are available for download by the research community. PMID:27306137

  7. Accuracy evaluation of fluoroscopy-based 2D and 3D pose reconstruction with unicompartmental knee arthroplasty.

    PubMed

    Van Duren, B H; Pandit, H; Beard, D J; Murray, D W; Gill, H S

    2009-04-01

    The recent development in Oxford lateral unicompartmental knee arthroplasty (UKA) design requires a valid method of assessing its kinematics. In particular, the use of single plane fluoroscopy to reconstruct the 3D kinematics of the implanted knee. The method has been used previously to investigate the kinematics of UKA, but mostly it has been used in conjunction with total knee arthroplasty (TKA). However, no accuracy assessment of the method when used for UKA has previously been reported. In this study we performed computer simulation tests to investigate the effect of the different geometry of the unicompartmental implant has on the accuracy of the method in comparison to the total knee implants. A phantom was built to perform in vitro tests to determine the accuracy of the method for UKA. The computer simulations suggested that the use of the method for UKA would prove less accurate than for TKA's. The rotational degrees of freedom for the femur showed greatest disparity between the UKA and TKA. The phantom tests showed that the in-plane translations were accurate to <0.5mm RMS and the out-of-plane translations were less accurate with 4.1mm RMS. The rotational accuracies were between 0.6 degrees and 2.3 degrees which are less accurate than those reported in the literature for TKA, however, the method is sufficient for studying overall knee kinematics.

  8. Impact of Educational and Patient Decision Aids on Decisional Conflict Associated with Total Knee Arthroplasty

    PubMed Central

    de Achaval, Sofia; Fraenkel, Liana; Volk, Robert J.; Cox, Vanessa; Suarez-Almazor, Maria E.

    2012-01-01

    Our objective was to examine the impact of a videobooklet patient decision aid supplemented by an interactive values clarification exercise on decisional conflict in patients with knee osteoarthritis (OA) considering total knee arthroplasy. 208 patients participated in the study (mean age 63 years; 68% female; 66% White). Participants were randomized to 1 of 3 groups: (1) Educational booklet on OA management (control); (2) Patient decision aid (videobooklet) on OA management; and (3) Patient decision aid (videobooklet) + adaptive conjoint analysis ACA tool. The ACA tool enables patients to consider competing attributes (i.e. specific risks/benefits) by asking them to rate a series of paired-comparisons. The primary outcome was the decisional conflict scale ranging from 0 to 100. Differences between groups were analyzed using analysis of variance (ANOVA) and Tukey's honestly significant difference tests. Overall, decisional conflict decreased significantly in all groups (p<0.05). The largest reduction in decisional conflict was observed for participants in the videobooklet decision aid group (21 points). Statistically significant differences in pre vs. post-intervention total scores favored the videobooklet group compared to the control group (21 vs. 10) and to the videobooklet plus ACA group (21 vs. 14; p<0.001). Changes in the decisional conflict score for the control compared to the videobooklet decision aid + ACA group were not significantly different. In our study, an audiovisual patient decision aid decreased decisional conflict more than printed material alone, or than the addition of a more complex computer-based ACA tool requiring more intense cognitive involvement and explicit value choices. PMID:21954198

  9. Relationship of unilateral total hip arthroplasty (THA) to contralateral and ipsilateral knee joint degeneration - a longitudinal 3T MRI study from the Osteoarthritis Initiative (OAI).

    PubMed

    Jungmann, P M; Nevitt, M C; Baum, T; Liebl, H; Nardo, L; Liu, F; Lane, N E; McCulloch, C E; Link, T M

    2015-07-01

    To evaluate the association of prevalent unilateral total hip arthroplasty (THA) with worsening of degenerative knee abnormalities and clinical outcomes in the ipsilateral and contralateral knee. Both knees of 30 individuals in the Osteoarthritis Initiative (OAI) with unilateral THA (n = 14 left, n = 16 right) at baseline were assessed at baseline and at 4-year follow-up for Whole-organ MR Imaging Scores (WORMS), cartilage T2 relaxation times (only available for right knees), Western Ontario and McMasters Universities Arthritis Index (WOMAC) scores and upper leg isometric strength. Right knees of 30 individuals without THA were analyzed as controls. Contralateral knees were compared to ipsilateral knees with paired t-tests and to control knees with multivariate regression analysis adjusting for covariates. In paired analyses, compared to ipsilateral knees, contralateral knees had higher WORMS total (P = 0.008) and cartilage scores (P = 0.007) at baseline. Over 4 years contralateral knees worsened more on WORMS total score (P = 0.008). Cartilage T2 values were higher in knees contralateral to the THA (baseline, P = 0.02; follow-up, P < 0.001). Contralateral knees had greater declines in knee extension strength (P = 0.04) and had a trend for greater worsening in WOMAC pain, stiffness, function and total scores (P = 0.04-0.09). Similar results were found comparing contralateral knees with control knees in multivariate regression models. Prevalent unilateral THA is associated with an greater progression of degenerative findings for the knee contralateral to THA. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  10. Differences in knee flexion between the Genium and C-Leg microprocessor knees while walking on level ground and ramps.

    PubMed

    Lura, Derek J; Wernke, Matthew M; Carey, Stephanie L; Kahle, Jason T; Miro, Rebecca M; Highsmith, M Jason

    2015-02-01

    Microprocessor knees have improved the gait and functional abilities of persons with transfemoral amputation. The Genium prosthetic knee offers an advanced sensor and control system designed to decrease impairment by: allowing greater stance phase flexion, easing transitions between gait phases, and compensating for changes in terrain. The aim of this study was to determine differences between the knee flexion angle of persons using the Genium knee, the C-Leg knee, and non-amputee controls; and to evaluate the impact the prostheses on gait and level of impairment of the user. This study used a randomized experimental crossover of persons with transfemoral amputation using the Genium and C-Leg microprocessor knees (n=25), with an observational sample of non-amputee controls (n=5). Gait analysis by 3D motion tracking of subjects ambulating at different speeds on level ground and on 5° and 10° ramps was completed. Use of the Genium resulted in a significant increase in peak knee flexion for swing (5°, p<0.01, d=0.34) and stance (2°, p<0.01, d=0.19) phases relative to C-Leg use. There was a high degree of variability between subjects, and significant differences still remain between the Genium group and the control group's knee flexion angles for most speeds and slopes. The Genium knee generally increases flexion in swing and stance, potentially decreasing the level of impairment for persons with transfemoral amputation. This study demonstrates functional differences between the C-Leg and Genium knees to help prosthetists determine if the Genium will provide functional benefits to individual patients. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Dependence of muscle moment arms on in-vivo three-dimensional kinematics of the knee

    PubMed Central

    Navacchia, Alessandro; Kefala, Vasiliki; Shelburne, Kevin B.

    2016-01-01

    Quantification of muscle moment arms is important for clinical evaluation of muscle pathology and treatment, and for estimating muscle and joint forces in musculoskeletal models. Moment arms estimated with musculoskeletal models often assume a default motion of the knee derived from measurements of passive cadaveric flexion. However, knee kinematics are unique to each person and activity. The objective of this study was to estimate moment arms of the knee muscles with in vivo subject- and activity-specific kinematics from seven healthy subjects performing seated knee extension and single-leg lunge to show changes between subjects and activities. 3D knee motion was measured with a high-speed stereo-radiography system. Moment arms of ten muscles were estimated in OpenSim by replacing the default knee motion with in vivo measurements. Estimated inter-subject moment arm variability was similar to previously reported in vitro measurements. RMS deviations up to 9.0 mm (35.2% of peak value) were observed between moment arms estimated with subject-specific knee extension and passive cadaveric motion. The degrees of freedom that most impacted inter-activity differences were superior/inferior and anterior/posterior translations. Musculoskeletal simulations used to estimate in vivo muscle forces and joint loads may provide significantly different results when subject- and activity-specific kinematics are implemented. PMID:27620064

  12. Dependence of Muscle Moment Arms on In Vivo Three-Dimensional Kinematics of the Knee.

    PubMed

    Navacchia, Alessandro; Kefala, Vasiliki; Shelburne, Kevin B

    2017-03-01

    Quantification of muscle moment arms is important for clinical evaluation of muscle pathology and treatment, and for estimating muscle and joint forces in musculoskeletal models. Moment arms estimated with musculoskeletal models often assume a default motion of the knee derived from measurements of passive cadaveric flexion. However, knee kinematics are unique to each person and activity. The objective of this study was to estimate moment arms of the knee muscles with in vivo subject- and activity-specific kinematics from seven healthy subjects performing seated knee extension and single-leg lunge to show changes between subjects and activities. 3D knee motion was measured with a high-speed stereo-radiography system. Moment arms of ten muscles were estimated in OpenSim by replacing the default knee motion with in vivo measurements. Estimated inter-subject moment arm variability was similar to previously reported in vitro measurements. RMS deviations up to 9.0 mm (35.2% of peak value) were observed between moment arms estimated with subject-specific knee extension and passive cadaveric motion. The degrees of freedom that most impacted inter-activity differences were superior/inferior and anterior/posterior translations. Musculoskeletal simulations used to estimate in vivo muscle forces and joint loads may provide significantly different results when subject- and activity-specific kinematics are implemented.

  13. Three-dimensional in vivo patellofemoral kinematics and contact area of anterior cruciate ligament-deficient and -reconstructed subjects using magnetic resonance imaging.

    PubMed

    Shin, Choongsoo S; Carpenter, R Dana; Majumdar, Sharmila; Ma, C Benjamin

    2009-11-01

    The purpose of this study was to test whether (1) the 3-dimensional in vivo patellofemoral kinematics and patellofemoral contact area of anterior cruciate ligament (ACL)-deficient knees are different from those of normal, contralateral knees and (2) ACL reconstruction restores in vivo patellofemoral kinematics and contact area. Ten ACL-deficient knees and twelve ACL-reconstructed knees, as well as the contralateral uninjured knees, were tested. Magnetic resonance imaging was performed at full extension and 40 degrees of flexion under simulated partial weight-bearing conditions. Six-degrees of freedom patellofemoral kinematics, patellofemoral contact area, and contact location were analyzed by use of magnetic resonance image-based 3-dimensional patellofemoral knee models. The patella in the ACL-deficient knees underwent significantly more lateral tilt during flexion (P < .05) and tended to translate more laterally (P = .083) than the patella in contralateral knees. After ACL reconstruction, no kinematic parameters were significantly different from those in contralateral knees. The patellofemoral contact areas of ACL-deficient knees at both the extended and flexed positions (37 +/- 22 mm(2) and 357 +/- 53 mm(2), respectively) were significantly smaller than those of contralateral knees (78 +/- 45 mm(2) and 437 +/- 119 mm(2), respectively) (P < .05). After reconstruction, the patellofemoral contact area of ACL-reconstructed knees in the extended position (86 +/- 41 mm(2)) was significantly larger (P < .05) than that of contralateral knees (50 +/- 34 mm(2)), but no difference was detected in the flexed position. Reproducibility of all patellofemoral kinematic parameters, contact centroid translation, and contact area showed coefficients of variation of less than 6.8%. ACL injuries alter patellofemoral kinematics including patellar tilt and patellar lateral translation, but ACL reconstruction with hamstring or allograft restores altered patellar tilt. ACL injuries reduce the patellofemoral contact area at both the extended and flexed positions, but ACL reconstruction enlarges the patellofemoral contact area at extension and restores the normal contact area at low angles of flexion. Level III, case-control study.

  14. Knee joint kinaesthesia and neuromuscular coordination during three phases of the menstrual cycle in moderately active women.

    PubMed

    Fridén, Cecilia; Hirschberg, Angelica Lindén; Saartok, Tönu; Renström, Per

    2006-04-01

    An increased incidence of sports related injuries in the premenstrual phase as well as in the menstrual phase of the menstrual cycle has been described. This may be explained by alterations in proprioception and neuromuscular coordination due to hormonal variations. Prospective, within women analysis of knee joint kinesthesia and neuromuscular coordination were performed by repeated measures analysis of variance in three hormonally verified phases of three consecutive menstrual cycles. Thirty-two healthy, moderately active female subjects volunteered to participate in the study. Twenty-five of the subjects performed at least one hormonally verified menstrual cycle. A specially designed device was used to investigate knee joint kinaesthesia and neuromuscular coordination was measured with the square hop test. These tests were carried out in the menstrual phase, ovulation phase and premenstrual phase determined by hormone analyses in three consecutive menstrual cycles. An impaired knee joint kinaesthesia was detected in the premenstrual phase and the performance of square hop test was significantly improved in the ovulation phase compared to the other two phases. The results of this study indicate that the variation of sex hormones in the menstrual cycle has an effect on performance of knee joint kinaesthesia and neuromuscular coordination.

  15. Efficacy of kinesio taping on isokinetic quadriceps torque in knee osteoarthritis: a double blinded randomized controlled study.

    PubMed

    Anandkumar, Sudarshan; Sudarshan, Shobhalakshmi; Nagpal, Pratima

    2014-08-01

    Double blind pre-test post-test control group design. To compare the isokinetic quadriceps torque, standardized stair-climbing task (SSCT) and pain during SSCT between subjects diagnosed with knee osteoarthritis pre and post kinesio tape (KT) application with and without tension. Strength of the quadriceps and torque producing capability is frequently found to be compromised in knee osteoarthritis. The efficacy of KT in improving isokinetic quadriceps torque in knee osteoarthritis is unknown, forming the basis for this study. Forty subjects were randomly allocated to either the experimental (therapeutic KT with tension) or control group (sham KT without tension) with the allocation being concealed. Pre and post test measurements of isokinetic quadriceps torque, SSCT and pain during SSCT were carried out by a blinded assessor. A large effect size with significant improvements in the peak quadriceps torque (concentric and eccentric at angular velocities of 90° per second and 120° per second), SSCT and pain were obtained in the experimental group when compared to the control group. Application of therapeutic KT is effective in improving isokinetic quadriceps torque, SSCT and reducing pain in knee osteoarthritis.

  16. Influence of bi- and tri-compartmental knee arthroplasty on the kinematics of the knee joint

    PubMed Central

    2011-01-01

    Background The cruciate ligaments are important stabilizers of the knee joint and determine joint kinematics in the natural knee and after cruciate retaining arthroplasty. No in vitro data is available to biomechanically evaluate the ability of the anterior cruciate ligament (ACL) to maintain knee joint kinematics after bicruciate-retaining bi-compartmental knee arthroplasty (BKA). Therefore, the objective of the current study was to investigate the kinematics of the natural knee joint, before and after installing bicruciate-retaining BKA and posterior cruciate retaining total knee arthroplasty. Specifically, we incorporated a dynamic knee simulator to simulate weight-bearing flexions on cadaveric knee specimen before and after surgical manipulations. Methods In this cadaveric study we investigated rotational and translational tibiofemoral kinematics during simulated weight-bearing flexions of the intact knee, after bi-compartmental knee arthroplasty (BKA+), after resecting the ACL in BKA (BKA-), and after posterior cruciate retaining total knee arthroplasty (TKA). Results Rotation of BKA+ is closest to the intact knee joint, whereas TKA shows significant differences from 30 to 90 degree of flexion. Within the tested flexion range (15 to 90 degree of flexion), there was no significant difference in the anterior-posterior translation among intact, BKA+, and TKA knees. Resecting the ACL in BKA leads to a significant anterior tibial translation. Conclusions BKA with intact cruciate ligaments resembles rotation and translation of the natural knee during a simulated weight-bearing flexion. It is a suitable treatment option for medial and patellofemoral osteoarthritis with advantages in rotational characteristics compared to TKA. PMID:21272328

  17. Gait adaptations in patients with chronic posterior instability of the knee.

    PubMed

    Hooper, D M; Morrissey, M C; Crookenden, R; Ireland, J; Beacon, J P

    2002-03-01

    A retrospective analysis was performed to assess gait in individuals with a long history of posterior knee instability. Descriptive study. There are few studies in the literature concerning evaluation of the biomechanics of the knee in patients with knee posterior instability. Nine individuals with posterior knee instability and a matched control group of uninjured subjects were tested in regards to knee kinematics and kinetics while walking and ascending and descending stairs. The mean follow up time for the individuals with posterior instability was 11.1 years. Individual satisfaction with the knee was measured by having participants complete the Flandry (also known as Hughston Clinic) self-assessment questionnaire. It was found that patients with knee posterior instability who indicated a higher level of satisfaction on the Flandry score walked in a manner that demonstrated greater peak knee extensor torque during stance phase, while less satisfied patients with knee posterior instability demonstrated lower peak knee extensor torque. There was a significant correlation between the self-assessment score and the peak knee extensor torque during level walking (P=0.003). During stair ascent and descent, patients with posterior instability averaged lower knee extensor torque and power than the control subjects, but those differences were only statistically significant in power while descending stairs (P=0.048). Individuals with chronic knee posterior instability modify their gait, and the adaptation can be predicted based upon the individuals self-assessment of their knee using the Flandry questionnaire. These data suggest that gait retraining may be a valuable addition to the traditional muscle strengthening programs, which are commonly used during conservative management of knee posterior instability.

  18. Contact Mechanics and Failure Modes of Compliant Polymeric Bearing Materials for Knee Cartilage Replacement

    NASA Astrophysics Data System (ADS)

    Tohfafarosh, Mariya Shabbir

    Osteoarthritis (OA) is the most common cause of disability affecting millions of people worldwide. Total knee replacement is the current state-of-the-art treatment to alleviate pain and improve mobility among patients in the late stage of knee OA. The current gold standard materials for total knee arthroplasty are cobalt-chromium and ultra-high molecular weight polyethylene (UHMWPE). However, wear debris and implant loosening-related revision persists; consequently, total knee replacements are not universally recommended for all patient subgroups with OA. This work explores the potential of using compliant polymeric materials in knee cartilage replacement devices, which are closer in lubrication and mechanical properties of articular cartilage, to prevent excessive removal of underlying bone and prolong the need for a total knee replacement. Two materials investigated in this thesis are polycarbonate urethane, Bionate 80A, and a novel hydrogel, Cyborgel, both of which have shown promising wear and lubrication properties under physiological loads. Polycarbonate urethane has been previously tested for the effects of gamma sterilization and has shown no significant changes in its mechanical strength or chemical bonds. Since an important aspect of medical device development is the sterilization process, this thesis first evaluated the effect of 30-35 kGy electron beam and gamma radiation on the polymer swell ratio, and the mechanical, chemical and tribological behavior of the novel hydrogel. Three different formulations were mechanically tested, and biphasic material properties were identified using finite element analysis. Fourier transform infrared spectroscopy was used to investigate chemical changes, while the wear properties were tested for 2 million cycles in bovine serum. The results showed no significant difference (p > 0.05) in the swell ratio, mechanical and tribological properties of the electron beam and gamma sterilized hydrogel sample as compared to the control samples. However, chemical spectra of electron beam sterilized samples revealed minor changes, which were absent in unsterilized and gamma sterilized samples. Upon successful sterilization evaluation, both polycarbonate urethane and the novel hydrogel were investigated for the contact mechanics of compliant-on-compliant artificial knee bearings using a finite element analysis approach. A simplified, axisymmetric, finite element model of a medial knee compartment was developed and validated, and a design of simulation experiments was carried out to evaluate the effect of implant conformity, implant thickness and material properties on the contact mechanics of compliant knee bearings under normal walking and stair climbing loads. All input parameters, namely, implant conformity, implant thickness and material properties, significantly (p<0.001) affected the maximum principal stress, Von Mises stress, maximum shear stress, maximum principal strain, maximum contact pressure and contact area. The knee implant contact mechanics demonstrated sensitivity to all the three design factors, and a correlation between resulting stresses and implant conformity as well as thickness was observed. However, the conformity had the highest effect-size on the contact mechanics. The maximum principal stress value halves and the contact area doubles when ≥ 95% implant conformity (i.e. the ratio of femoral to tibial surface’s radii of curvature) and ≥ 3mm thickness was used, hence, these parameters were recommended for the design of compliant knee bearings. Finally, a battery of mechanical tests was carried out to evaluate the failure criteria of the proposed compliant polymers under physiological loads and strain rates. Uniaxial tests, including tension and unconfined compression, and biaxial tests, such as plane strain compression, were carried out to characterize the mechanical behavior of different material formulations at physiologically relevant testing rates. The materials failed under tension between 250 - 750% true strain, while those under uniaxial and biaxial compression test sustained compression of 50 - 70% engineering strain (39 - 53% true strain) without any signs of cracking or fracture. The tension was determined to be the primary failure mode for the proposed materials, and the tensile test was used to define the failure criteria of the materials. The unconfined compression tests were used to define the yield stresses and strains under compression, which is the main mode of loading for the knee joint. The results of the plane strain compression were modeled using a finite element model and the maximum principal stress, von Mises stress, maximum shear stress, and maximum principal strain failure criteria were predicted at the corresponding yield strain of each material formulation. Upon comparing the knee model contact stress and strain prediction under normal walking and stair climbing loads with those of the empirical failure criteria at yield, the polycarbonate urethane showed better overall potential for use in compliant knee implants, while the hydrogels exhibited higher potential for delamination or fracture, especially if appropriate implant conformity and thickness are not employed. The outcome of this study and the previous parametric model results helped to determine a niche design space within which designing a knee implant with compliant bearing materials may be feasible. In summary, the potential of compliant bearing materials was thoroughly examined in this thesis, and the results provided a foundation for future testing and development of a compliant cartilage replacement implant. Such an implant would be a promising improvement and alternative to conventional total knee replacements.

  19. Associations between physical examination and self-reported physical function in older community-dwelling adults with knee pain.

    PubMed

    Wood, Laurence; Peat, George; Thomas, Elaine; Hay, Elaine M; Sim, Julius

    2008-01-01

    Knee pain is a common disabling condition for which older people seek primary care. Clinicians depend on the history and physical examination to direct treatment. The purpose of this study was to examine the associations between simple physical examination tests and self-reported physical functional limitations. A population sample of 819 older adults underwent a standardized physical examination consisting of 24 tests. Associations between the tests and self-reported physical functional limitations (Western Ontario and McMaster Universities Osteoarthritis Index physical functioning subscale [WOMAC-PF] scores) were explored. Five of the tests showed correlations with WOMAC-PF scores, corresponding to an intermediate effect (r>or=.30). These were tenderness on palpation of the infrapatellar area, timed single-leg standing balance, maximal isometric quadriceps femoris muscle strength (force-generating capacity), reproduction of symptoms on patellofemoral compression, and degree of knee flexion. Each of these tests was able to account for between 7% and 13% of the variance in WOMAC-PF scores, after controlling for age, sex, and body mass index. Three of these tests are indicative of impairments that may be modifiable by exercise interventions. Self-reported physical functional limitations among older people with knee pain are associated with potentially modifiable physical impairments that can be identified by simple physical examination tests.

  20. Knee Proprioception and Strength and Landing Kinematics During a Single-Leg Stop-Jump Task

    PubMed Central

    Nagai, Takashi; Sell, Timothy C; House, Anthony J; Abt, John P; Lephart, Scott M

    2013-01-01

    Context The importance of the sensorimotor system in maintaining a stable knee joint has been recognized. As individual entities, knee-joint proprioception, landing kinematics, and knee muscles play important roles in functional joint stability. Preventing knee injuries during dynamic tasks requires accurate proprioceptive information and adequate muscular strength. Few investigators have evaluated the relationship between knee proprioception and strength and landing kinematics. Objective To examine the relationship between knee proprioception and strength and landing kinematics. Design Cross-sectional study. Setting University research laboratory. Patients or Other Participants Fifty physically active men (age = 26.4 ± 5.8 years, height = 176.5 ± 8.0 cm, mass = 79.8 ± 16.6 kg). Intervention(s) Three tests were performed. Knee conscious proprioception was evaluated via threshold to detect passive motion (TTDPM). Knee strength was evaluated with a dynamometer. A 3-dimensional biomechanical analysis of a single-legged stop-jump task was used to calculate initial contact (IC) knee-flexion angle and knee-flexion excursion. Main Outcome Measure(s) The TTDPM toward knee flexion and extension, peak knee flexion and extension torque, and IC knee-flexion angle and knee flexion excursion. Linear correlation and stepwise multiple linear regression analyses were used to evaluate the relationships of both proprioception and strength against landing kinematics. The α level was set a priori at .05. Results Enhanced TTDPM and greater knee strength were positively correlated with greater IC knee-flexion angle (r range = 0.281–0.479, P range = .001–.048). The regression analysis revealed that 27.4% of the variance in IC knee-flexion angle could be accounted for by knee-flexion peak torque and TTDPM toward flexion (P = .001). Conclusions The current research highlighted the relationship between knee proprioception and strength and landing kinematics. Individuals with enhanced proprioception and muscular strength had better control of IC knee-flexion angle during a dynamic task. PMID:23672323

  1. Development and Psychometric Testing of a Scale for Evaluating Self-Management Needs of Knee Osteoarthritis (SMNKOA) in Taiwan.

    PubMed

    Kao, Mei-Hua; Tsai, Yun-Fang

    2017-06-01

    Self-management of osteoarthritis (OA) of the knee is important for treating this chronic disease. This study developed and psychometrically tested a new instrument for measuring adult patients' self-management needs of knee osteoarthritis (SMNKOA). The theoretical framework of self-care guided the development of the 35-item SMNKOA scale. Participants ( N = 372) were purposively sampled from orthopedic clinics at medical centers in Taiwan. The content validity index was 0.83. Principal components analysis identified a three-factor solution, accounting for 53.19% of the variance. The divergent validity was -0.67; convergent validity was -0.51. Cronbach's alpha was .95, Pearson's correlation coefficient was .88, and the intraclass correlation coefficient was .95. The scale's reliability and validity supports the SMNKOA, as a tool to measure self-management needs of adults with knee OA. Nurses and other health care providers can use this instrument to evaluate knee OA patients and identify strategies for improving health-related outcomes and patient education.

  2. Energy absorption of impacts during running at various stride lengths.

    PubMed

    Derrick, T R; Hamill, J; Caldwell, G E

    1998-01-01

    The foot-ground impact experienced during running produces a shock wave that is transmitted through the human skeletal system. This shock wave is attenuated by deformation of the ground/shoe as well as deformation of biological tissues in the body. The goal of this study was to investigate the locus of energy absorption during the impact phase of the running cycle. Running speed (3.83 m x s[-1]) was kept constant across five stride length conditions: preferred stride length (PSL), +10% of PSL, -10% of PSL, +20% of PSL, and -20% of PSL. Transfer functions were generated from accelerometers attached to the leg and head of ten male runners. A rigid body model was used to estimate the net energy absorbed at the hip, knee, and ankle joints. There was an increasing degree of shock attenuation as stride length increased. The energy absorbed during the impact portion of the running cycle also increased with stride length. Muscles that cross the knee joint showed the greatest adjustment in response to increased shock. It was postulated that the increased perpendicular distance from the line of action of the resultant ground reaction force to the knee joint center played a role in this increased energy absorption.

  3. Association of lower extremity range of motion and muscle strength with physical performance of community-dwelling older women.

    PubMed

    Jung, Hungu; Yamasaki, Masahiro

    2016-12-08

    Reduced lower extremity range of motion (ROM) and muscle strength are related to functional disability in older adults who cannot perform one or more activities of daily living (ADL) independently. The purpose of this study was to determine which factors of seven lower extremity ROMs and two muscle strengths play dominant roles in the physical performance of community-dwelling older women. Ninety-five community-dwelling older women (mean age ± SD, 70.7 ± 4.7 years; age range, 65-83 years) were enrolled in this study. Seven lower extremity ROMs (hip flexion, hip extension, knee flexion, internal and external hip rotation, ankle dorsiflexion, and ankle plantar flexion) and two muscle strengths (knee extension and flexion) were measured. Physical performance tests, including functional reach test (FRT), 5 m gait test, four square step test (FSST), timed up and go test (TUGT), and five times sit-to-stand test (FTSST) were performed. Stepwise regression models for each of the physical performance tests revealed that hip extension ROM and knee flexion strength were important explanatory variables for FRT, FSST, and FTSST. Furthermore, ankle plantar flexion ROM and knee extension strength were significant explanatory variables for the 5 m gait test and TUGT. However, ankle dorsiflexion ROM was a significant explanatory variable for FRT alone. The amount of variance on stepwise multiple regression for the five physical performance tests ranged from 25 (FSST) to 47% (TUGT). Hip extension, ankle dorsiflexion, and ankle plantar flexion ROMs, as well as knee extension and flexion strengths may play primary roles in the physical performance of community-dwelling older women. Further studies should assess whether specific intervention programs targeting older women may achieve improvements in lower extremity ROM and muscle strength, and thereby play an important role in the prevention of dependence on daily activities and loss of physical function, particularly focusing on hip extension, ankle dorsiflexion, and ankle plantar flexion ROMs as well as knee extension and flexion strength.

  4. Knee Joint Contact Mechanics during Downhill Gait and its Relationship with Varus/Valgus Motion and Muscle Strength in Patients with Knee Osteoarthritis

    PubMed Central

    Farrokhi, Shawn; Voycheck, Carrie A.; Gustafson, Jonathan A.; Fitzgerald, G. Kelley; Tashman, Scott

    2015-01-01

    Objective The objective of this exploratory study was to evaluate tibiofemoral joint contact point excursions and velocities during downhill gait and assess the relationship between tibiofemoral joint contact mechanics with frontal-plane knee joint motion and lower extremity muscle weakness in patients with knee osteoarthritis (OA). Methods Dynamic stereo X-ray was used to quantify tibiofemoral joint contact mechanics and frontal-plane motion during the loading response phase of downhill gait in 11 patients with knee OA and 11 control volunteers. Quantitative testing of the quadriceps and the hip abductor muscles was also performed. Group differences in contact mechanics and frontal-plane motion excursions were compared using analysis of covariance with adjustments for body mass index. Differences in strength were compared using independent sample t-tests. Additionally, linear associations between contact mechanics with frontal-plane knee motion and muscle strength were evaluated using Pearson's correlation coefficients. Results Patients with knee OA demonstrated larger medial/lateral joint contact point excursions (p<0.02) and greater heel-strike joint contact point velocities (p<0.05) for the medial and lateral compartments compared to the control group. The peak medial/lateral joint contact point velocity of the medial compartment was also greater for patients with knee OA compared to their control counterparts (p=0.02). Additionally, patients with knee OA demonstrated significantly increased frontal-plane varus motion excursions (p<0.01) and greater quadriceps and hip abductor muscle weakness (p=0.03). In general, increased joint contact point excursions and velocities in patients with knee OA were linearly associated with greater frontal-plane varus motion excursions (p<0.04) but not with quadriceps or hip abductor strength. Conclusion Altered contact mechanics in patients with knee OA may be related to compromised frontal-plane joint stability but not with deficits in muscle strength. PMID:27030846

  5. Prosthetic knee design by simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hollerbach, K; Hollister, A

    1999-07-30

    Although 150,000 total knee replacement surgeries are performed annually in North America, current designs of knee prostheses have mechanical problems that include a limited range of motion, abnormal gait patterns, patellofemoral joint dysfunction, implant loosening or subsidence, and excessive wear. These problems fall into three categories: failure to reproduce normal joint kinematics, which results in altered limb function; bone-implant interface failure; and material failure. Modern computer technology can be used to design, prototype, and test new total knee implants. The design team uses the full range of CAD-CAM to design and produce implant prototypes for mechanical and clinical testing. Closermore » approximation of natural knee kinematics and kinetics is essential for improved patient function and diminished implant loads. Current knee replacement designs are based on 19th Century theories that the knee moves about a variable axis of rotation. Recent research has shown, however, that knee motion occurs about two fixed, offset axes of rotation. These aces are not perpendicular to the long axes of the bones or to each other, and the axes do not intersect. Bearing surfaces of mechanisms that move about axes of rotation are surfaces of revolution of those axes which advanced CAD technology can produce. Solids with surfaces of revolution for the two axes of rotation for the knee have been made using an HP9000 workstation and Structural Ideas Master Series CAD software at ArthroMotion. The implant's CAD model should closely replicate movements of the normal knee. The knee model will have a range of flexion-extension (FE) from -5 to 120 degrees. Movements include varus, valgus, internal and external rotation, as well as flexion and extension. The patellofemoral joint is aligned perpendicular to the FE axis and replicates the natural joint more closely than those of existing prostheses. The bearing surfaces will be more congruent than current designs and should generate lower stresses in the materials.« less

  6. Evaluation of knee joint forces during kneeling work with different kneepads.

    PubMed

    Xu, Hang; Jampala, Sree; Bloswick, Donald; Zhao, Jie; Merryweather, Andrew

    2017-01-01

    The main purpose of this study is to determine knee joint forces resulting from kneeling work with and without kneepads to quantify how different kneepads redistribute force. Eleven healthy males simulated a tile setting task to different locations during six kneepad states (five different kneepad types and without kneepad). Peak and average forces on the anatomical landmarks of both knees were obtained by custom force sensors. The results revealed that kneepad design can significantly modify the forces on the knee joint through redistribution. The Professional Gel design was preferred among the five tested kneepads which was confirmed with both force measurements and participants' responses. The extreme reaching locations induced significantly higher joint forces on left knee or right knee depending on task. The conclusion of this study is that a properly selected kneepad for specific tasks and a more neutral working posture can modify the force distribution on the knees and likely decrease the risk of knee disorders from kneeling work. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Design and energetic evaluation of a prosthetic knee joint actuator with a lockable parallel spring.

    PubMed

    Geeroms, J; Flynn, L; Jimenez-Fabian, R; Vanderborght, B; Lefeber, D

    2017-02-03

    There are disadvantages to existing damping knee prostheses which cause an asymmetric gait and higher metabolic cost during level walking compared to non-amputees. Most existing active knee prostheses which could benefit the amputees use a significant amount of energy and require a considerable motor. In this work, a novel semi-active actuator with a lockable parallel spring for a prosthetic knee joint has been developed and tested. This actuator is able to provide an approximation of the behavior of a healthy knee during most of the gait cycle of level walking. This actuator is expanded with a series-elastic actuator to mimic the full gait cycle and enable its use in other functional tasks like stair climbing and sit-to-stance. The proposed novel actuator reduces the energy consumption for the same trajectory with respect to a compliant or directly-driven prosthetic active knee joint and improves the approximation of healthy knee behavior during level walking compared to passive or variable damping knee prostheses.

  8. [Effect of posterior cruciate ligament retaining or not on knee-joint proprioception].

    PubMed

    Wu, Yansheng; Li, Yongsheng; Chen, Baicheng

    2013-07-01

    To analyze the effect of the posterior cruciate ligament (PCL) retaining or not on knee-joint proprioception by comparing the proprioceptive difference between PCL retaining and no PCL retaining in total knee arthroplasty (TKA). Between June 2009 and June 2010, 38 osteoarthritis patients meeting the inclusion criteria were divided into PCL retaining group (group A, n=19) and PCL-substituting group (group B, n=19) according to the random number table. There was no significant difference in gender, age, disease duration, the range of motion of the knee between 2 groups (P > 0.05). The effectiveness and the knee-joint proprioception were separately assessed by the Western Ontario and McMaster University Osteoarthritis Index (WOMAC) score and the passive angle reproduction test (30, 60, and 90 degrees of knee flexion) preoperatively and 12 months postoperatively. All incisons healed by first intention, without complications of infection, fracture, and deep vein thrombosis of lower limb. The patients were followed up 12-17 months (mean, 14.1 months). The knee function after operation was obviously improved when compared with preoperative one; significant differences were observed in the WOMAC scores and the results of passive angle reproduction test between at preoperation and at 12 months after operation (P < 0.05), but no significant difference was found between group A and group B (P > 0.05). Whether PCL retaining or not in TKA both can improve knee-joint proprioception, and no obvious difference between them.

  9. The effect of Ai Chi aquatic therapy on individuals with knee osteoarthritis: a pilot study.

    PubMed

    So, Billy C L; Kong, Iris S Y; Lee, Roy K L; Man, Ryan W F; Tse, William H K; Fong, Adalade K W; Tsang, William W N

    2017-05-01

    [Purpose] To examine the efficacy of Ai Chi in relieving the pain and stiffness of knee osteoarthritis and improving, physical functioning, proprioception and quality of life. [Subjects and Methods] Twenty-five persons with knee osteoarthritis completed 5 weeks Ai Chi practice (60 minutes per session, twice per week, 10 sessions in total). Knee pain and stiffness were measured before and after the intervention program. [Results] Significant improvements in pain, self-perceived physical functioning and self-perceived stiffness were observed after the Ai-Chi intervention. On average, no significant change in knee range of motion, 6-minute walk test distances or proprioception was observed. [Conclusion] A five-week Ai Chi intervention can improve the pain and stiffness of knee osteoarthritis and self-perceived physical functions and quality of life improvement. Ai Chi may be another treatment choice for people with knee OA to practice in the community.

  10. Comparison of robot surgery modular and total knee arthroplasty kinematics.

    PubMed

    Yildirim, Gokce; Fernandez-Madrid, Ivan; Schwarzkopf, Ran; Walker, Peter S; Karia, Raj

    2014-04-01

    The kinematics of seven knee specimens were measured from 0 to 120 degrees flexion using an up-and-down crouching machine. Motion was characterized by the positions of the centers of the lateral and medial femoral condyles in the anterior-posterior direction relative to a fixed tibia. A modular unicompartmental knee, trochlea flange, and patella resurfacing (multicompartmental knee [MCK] system) were implanted using a surgeon-interactive robot system that provided accurate surface matching. The MCK was tested, followed by standard cruciate retaining (CR) and posterior stabilized (PS) knees. The motion of the MCK was close to anatomic, especially on the medial side, in contrast to the CR and PS knees that showed abnormal motion features. Such a modular knee system, accurately inserted, has the potential for close to normal function in clinical application. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  11. Development and fabrication of patient-specific knee implant using additive manufacturing techniques

    NASA Astrophysics Data System (ADS)

    Zammit, Robert; Rochman, Arif

    2017-10-01

    Total knee replacement is the most effective treatment to relief pain and restore normal function in a diseased knee joint. The aim of this research was to develop a patient-specific knee implant which can be fabricated using additive manufacturing techniques and has reduced wear rates using a highly wear resistant materials. The proposed design was chosen based on implant requirements, such as reduction in wear rates as well as strong fixation. The patient-specific knee implant improves on conventional knee implants by modifying the articulating surfaces and bone-implant interfaces. Moreover, tribological tests of different polymeric wear couples were carried out to determine the optimal materials to use for the articulating surfaces. Finite element analysis was utilized to evaluate the stresses sustained by the proposed design. Finally, the patient-specific knee implant was successfully built using additive manufacturing techniques.

  12. Finite element analysis of constrained total Condylar Knee Prosthesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-07-13

    Exactech, Inc., is a prosthetic joint manufacturer based in Gainesville, FL. The company set the goal of developing a highly effective prosthetic articulation, based on scientific principles, not trial and error. They developed an evolutionary design for a total knee arthroplasty system that promised improved performance. They performed static load tests in the laboratory with similar previous designs, but dynamic laboratory testing was both difficult to perform and prohibitively expensive for a small business to undertake. Laboratory testing also cannot measure stress levels in the interior of the prosthesis where failures are known to initiate. To fully optimize their designsmore » for knee arthroplasty revisions, they needed range-of-motion stress/strain data at interior as well as exterior locations within the prosthesis. LLNL developed computer software (especially NIKE3D) specifically designed to perform stress/strain computations (finite element analysis) for complex geometries in large displacement/large deformation conditions. Additionally, LLNL had developed a high fidelity knee model for other analytical purposes. The analysis desired by Exactech could readily be performed using NIKE3D and a modified version of the high fidelity knee that contained the geometry of the condylar knee components. The LLNL high fidelity knee model was a finite element computer model which would not be transferred to Exactech during the course of this CRADA effort. The previously performed laboratory studies by Exactech were beneficial to LLNL in verifying the analytical capabilities of NIKE3D for human anatomical modeling. This, in turn, gave LLNL further entree to perform work-for-others in the prosthetics field. There were two purposes to the CRADA (1) To modify the LLNL High Fidelity Knee Model to accept the geometry of the Exactech Total Knee; and (2) To perform parametric studies of the possible design options in appropriate ranges of motion so that an optimum design could be selected for production. Because of unanticipated delays in the CRADA funding, the knee design had to be finalized before the analysis could be accomplished. Thus, the scope of work was modified by the industrial partner. It was decided that it would be most beneficial to perform FEA that would closely replicate the lab tests that had been done as the basis of the design. Exactech was responsible for transmitting the component geometries to Livermore, as well as providing complete data from the quasi-static laboratory loading tests that were performed on various designs. LLNL was responsible for defining the basic finite element mesh and carrying out the analysis. We performed the initial computer simulation and verified model integrity, using the laboratory data. After performing the parametric studies, the results were reviewed with Exactech. Also, the results were presented at the Orthopedic Research Society meeting in a poster session.« less

  13. Neurodynamic responses to the femoral slump test in patients with anterior knee pain syndrome.

    PubMed

    Lin, Pei-Ling; Shih, Yi-Fen; Chen, Wen-Yin; Ma, Hsiao-Li

    2014-05-01

    Matched-control, cross-sectional study. The purpose of this study was to compare the responses to the femoral slump test (FST), including the change in hip range of motion and level of discomfort, between subjects with and without anterior knee pain. Anterior knee pain syndrome is a common problem among adults. The FST is the neurodynamic test used to assess the mechanosensitivity of the femoral component of the nervous system. However, as of yet, there is no literature discussing the use of the FST in patients with anterior knee pain. Thirty patients with anterior knee pain and 30 control participants, matched by gender, age, and dominant leg, were recruited. The subjects received the FST, during which the hip extension angle and the location and intensity of pain/discomfort were recorded. Reproduction of symptoms that were alleviated by neck extension was interpreted as a positive test. Differences in hip extension angle and pain intensity between groups were examined using a 2-way, repeated-measures analysis of variance and a Kruskal-Wallis analysis. The level of significance was set at α = .05. Subjects with anterior knee pain had a smaller hip extension angle than that of controls (-3.6° ± 5.3° versus 0.6° ± 6.1°; mean difference, 4.2°; 95% confidence interval [CI]: 1.24°, 7.15°; P = .006). Eight patients with anterior knee pain showed a positive FST, and those with a positive FST had a smaller hip extension angle (-5.7° ± 4.5°) than that of controls (mean difference, 6.3°; 95% CI: 0.8°, 11.8°; P = .007). There was no difference in the hip extension angle between the positive and negative FST groups (mean difference, 2.9°; 95% CI: -8.5°, 2.0°) or between the negative FST and control groups (mean difference, 3.4°; 95% CI: -0.4°, 7.3°). Results of this study suggest that altered mechanosensitivity of the femoral nerve occurred in the patients with anterior knee pain who presented with a positive FST. The role of increased mechanosensitivity in the development and management of anterior knee pain should be investigated in the future.

  14. Preoperative Pain Neuroscience Education Combined With Knee Joint Mobilization for Knee Osteoarthritis: A Randomized Controlled Trial.

    PubMed

    Lluch, Enrique; Dueñas, Lirios; Falla, Deborah; Baert, Isabel; Meeus, Mira; Sánchez-Frutos, José; Nijs, Jo

    2018-01-01

    This study aimed to first compare the effects of a preoperative treatment combining pain neuroscience education (PNE) with knee joint mobilization versus biomedical education with knee joint mobilization on central sensitization (CS) in patients with knee osteoarthritis, both before and after surgery. Second, we wanted to compare the effects of both interventions on knee pain, disability, and psychosocial variables. Forty-four patients with knee osteoarthritis were allocated to receive 4 sessions of either PNE combined with knee joint mobilization or biomedical education with knee joint mobilization before surgery. All participants completed self-administered questionnaires and quantitative sensory testing was performed at baseline, after treatment and at a 1 month follow-up (all before surgery), and at 3 months after surgery. Significant and clinically relevant differences before and after surgery were found after treatments for both knee pain and disability, and some measures of CS (ie, widespread hyperalgesia, CS inventory), with no significant between-group differences. Other indicators of CS (ie, conditioned pain modulation, temporal summation) did not change over time following either treatment, and in some occasions the observed changes were not in the expected direction. Patients receiving PNE with knee joint mobilization achieved greater improvements in psychosocial variables (pain catastrophizing, kinesiophobia) both before and after surgery. Preoperative PNE combined with knee joint mobilization did not produce any additional benefits over time for knee pain and disability, and CS measures compared with biomedical education with knee joint mobilization. Superior effects in the PNE with knee joint mobilization group were only observed for psychosocial variables related to pain catastrophizing and kinesiophobia.

  15. Longitudinal tear of the medial meniscus posterior horn in the anterior cruciate ligament-deficient knee significantly influences anterior stability.

    PubMed

    Ahn, Jin Hwan; Bae, Tae Soo; Kang, Ki-Ser; Kang, Soo Yong; Lee, Sang Hak

    2011-10-01

    Longitudinal tears of the medial meniscus posterior horn (MMPH) are commonly associated with a chronic anterior cruciate ligament (ACL) deficiency. Many studies have demonstrated the importance of the medial meniscus in terms of limiting the amount of anterior-posterior tibial translation in response to anterior tibial loads in ACL-deficient knees. An MMPH tear in an ACL-deficient knee increases the anterior-posterior tibial translation and rotatory instability. In addition, MMPH repair will restore the tibial translation to the level before the tear. Controlled laboratory study. Ten human cadaveric knees were tested sequentially using a custom testing system under 5 conditions: intact, ACL deficient, ACL deficient with an MMPH peripheral longitudinal tear, ACL deficient with an MMPH repair, and ACL deficient with a total medial meniscectomy. The knee kinematics were measured at 0°, 15°, 30°, 60°, and 90° of flexion in response to a 134-N anterior and 200-N axial compressive tibial load. The rotatory kinematics were also measured at 15° and 30° of flexion in a combined rotatory load of 5 N·m of internal tibial torque and 10 N·m of valgus torque. Medial meniscus posterior horn longitudinal tears in ACL-deficient knees resulted in a significant increase in anterior-posterior tibial translation at all flexion angles except 90° (P < .05). An MMPH repair in an ACL-deficient knee showed a significant decrease in anterior-posterior tibial translation at all flexion angles except 60° compared with the ACL-deficient/MMPH tear state (P < .05). The total anterior-posterior translation of the ACL-deficient/MMPH repaired knee was not significantly increased compared with the ACL (only)-deficient knee but was increased compared with the ACL-intact knee (P > .05). A total medial meniscectomy in an ACL-deficient knee did not increase the anterior-posterior tibial translation significantly compared with MMPH tears in ACL-deficient knees at all flexion angles (P > .05). In a combined rotatory load, tibial rotation after MMPH tears or a total medial meniscectomy in an ACL-deficient knee were not affected significantly at all flexion angles. This study shows that an MMPH longitudinal tear in an ACL-deficient knee alters the knee kinematics, particularly the anterior-posterior tibial translation. MMPH repair significantly improved anterior-posterior tibial translation in ACL-deficient knees. These findings may help improve the treatment of patients with ACL and MMPH longitudinal tear by suggesting that the medial meniscal repairs should be performed for greater longevity when combined with an ACL reconstruction.

  16. Design and Control of a New Biomimetic Transfemoral Knee Prosthesis Using an Echo-Control Scheme

    PubMed Central

    2018-01-01

    Passive knee prostheses require a significant amount of additional metabolic energy to carry out a gait cycle, therefore affecting the natural human walk performance. Current active knee prostheses are still limited because they do not reply with accuracy of the natural human knee movement, and the time response is relatively large. This paper presents the design and control of a new biomimetic-controlled transfemoral knee prosthesis based on a polycentric-type mechanism. The aim was to develop a knee prosthesis able to provide additional power and to mimic with accuracy of the natural human knee movement using a stable control strategy. The design of the knee mechanism was obtained from the body-guidance kinematics synthesis based on real human walking patterns obtained from computer vision and 3D reconstruction. A biomechanical evaluation of the synthesized prosthesis was then carried out. For the activation and control of the prosthesis, an echo-control strategy was proposed and developed. In this echo-control strategy, the sound side leg is sensed and synchronized with the activation of the knee prosthesis. An experimental prototype was built and evaluated in a test rig. The results revealed that the prosthetic knee is able to mimic the biomechanics of the human knee. PMID:29854368

  17. CR TKA UHMWPE wear tested after artificial aging of the vitamin E treated gliding component by simulating daily patient activities.

    PubMed

    Schwiesau, Jens; Fritz, Bernhard; Kutzner, Ines; Bergmann, Georg; Grupp, Thomas M

    2014-01-01

    The wear behaviour of total knee arthroplasty (TKA) is dominated by two wear mechanisms: the abrasive wear and the delamination of the gliding components, where the second is strongly linked to aging processes and stress concentration in the material. The addition of vitamin E to the bulk material is a potential way to reduce the aging processes. This study evaluates the wear behaviour and delamination susceptibility of the gliding components of a vitamin E blended, ultra-high molecular weight polyethylene (UHMWPE) cruciate retaining (CR) total knee arthroplasty. Daily activities such as level walking, ascending and descending stairs, bending of the knee, and sitting and rising from a chair were simulated with a data set received from an instrumented knee prosthesis. After 5 million test cycles no structural failure of the gliding components was observed. The wear rate was with 5.62 ± 0.53 mg/million cycles falling within the limit of previous reports for established wear test methods.

  18. CR TKA UHMWPE Wear Tested after Artificial Aging of the Vitamin E Treated Gliding Component by Simulating Daily Patient Activities

    PubMed Central

    Schwiesau, Jens; Fritz, Bernhard; Kutzner, Ines; Bergmann, Georg; Grupp, Thomas M.

    2014-01-01

    The wear behaviour of total knee arthroplasty (TKA) is dominated by two wear mechanisms: the abrasive wear and the delamination of the gliding components, where the second is strongly linked to aging processes and stress concentration in the material. The addition of vitamin E to the bulk material is a potential way to reduce the aging processes. This study evaluates the wear behaviour and delamination susceptibility of the gliding components of a vitamin E blended, ultra-high molecular weight polyethylene (UHMWPE) cruciate retaining (CR) total knee arthroplasty. Daily activities such as level walking, ascending and descending stairs, bending of the knee, and sitting and rising from a chair were simulated with a data set received from an instrumented knee prosthesis. After 5 million test cycles no structural failure of the gliding components was observed. The wear rate was with 5.62 ± 0.53 mg/million cycles falling within the limit of previous reports for established wear test methods. PMID:25506594

  19. Effects of tibial slope changes in the stability of fixed bearing medial unicompartmental arthroplasty in anterior cruciate ligament deficient knees.

    PubMed

    Suero, Eduardo M; Citak, Musa; Cross, Michael B; Bosscher, Marianne R F; Ranawat, Anil S; Pearle, Andrew D

    2012-08-01

    Patients with anterior cruciate ligament (ACL) deficiency may have increased failure rates with UKA as a result of abnormal contact stresses and altered knee kinematics. Variations in the slope of the tibial component in UKA may alter tibiofemoral translation, and affect outcomes. This cadaveric study evaluated tibiofemoral translation during the Lachman and pivot shift tests after changing the slope of a fixed bearing unicondylar tibial component. Sectioning the ACL increased tibiofemoral translation in both the Lachman and pivot shift tests (P<0.05). Tibial slope leveling (decreasing the posterior slope) of the polyethylene insert in a UKA decreases anteroposterior tibiofemoral translation in the sagittal plane to a magnitude similar to that of the intact knee. With 8° of tibial slope leveling, anterior tibial translation during the Lachman test decreased by approximately 5mm. However, no variation in slope altered the pivot shift kinematics in the ACL deficient knees. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Clinical predictors of elective total joint replacement in persons with end-stage knee osteoarthritis.

    PubMed

    Zeni, Joseph A; Axe, Michael J; Snyder-Mackler, Lynn

    2010-05-06

    Arthritis is a leading cause of disability in the United States. Total knee arthroplasty (TKA) has become the gold standard to manage the pain and disability associated with knee osteoarthritis (OA). Although more than 400,000 primary TKA surgeries are performed each year in the United States, not all individuals with knee OA elect to undergo the procedure. No clear consensus exists on criteria to determine who should undergo TKA. The purpose of this study was to determine which clinical factors will predict the decision to undergo TKA in individuals with end-stage knee OA. Knowledge of these factors will aid in clinical decision making for the timing of TKA. Functional data from one hundred twenty persons with end-stage knee OA were obtained through a database. All of the individuals complained of knee pain during daily activities and had radiographic evidence of OA. Functional and clinical tests, collectively referred to as the Delaware Osteoarthritis Profile, were completed by a physical therapist. This profile consisted of measuring height, weight, quadriceps strength and active knee range of motion, while functional mobility was assessed using the Timed Up and Go (TUG) test and the Stair Climbing Task (SCT). Self-perceived functional ability was measured using the activities of daily living subscale of the Knee Outcome Survey (KOS-ADLS). A logistic regression model was used to identify variables predictive of TKA use. Forty subjects (33%) underwent TKA within two years of evaluation. These subjects were significantly older and had significantly slower TUG and SCT times (p < 0.05). Persons that underwent TKA were also significantly weaker, had lower self-reported function and had less knee extension than persons who did not undergo TKA. No differences between groups were seen for BMI, gender, knee flexion ROM and unilateral versus bilateral joint disease. Using backward regression, age, knee extension ROM and KOS-ADLS together significantly predicted whether or not a person would undergo TKA (p

  1. Do Independent Sector Treatment Centres (ISTC) Impact on Specialist Registrar Training in Primary Hip and Knee Arthroplasty?

    PubMed Central

    Clamp, Jonathan A; Baiju, Dean SR; Copas, David P; Hutchinson, James W; Rowles, John M

    2008-01-01

    INTRODUCTION The introduction of Modernising Medical Careers (MMC) is likely to reduce specialist registrar (SpR) operative experience during higher surgical training (HST). A further negative impact on training by local Independent Sector Treatment Centres (ISTCs) could reduce experience, and thus competence, in primary joint arthroplasty at completion of higher surgical training. PATIENTS AND METHODS Retrospective case note and radiograph analysis of patients receiving primary hip and knee arthroplasty in a teaching hospital, before and after the establishment of a local ISTC. Patients and operative details were recorded from the selected case notes. Corresponding radiographs were assessed and the severity of the disease process assessed. RESULTS Fewer primary hip and knee replacements were performed by SpRs in the time period after the establishment of an ISTC. Conclusions ISTCs may adversely affect SpR training in primary joint arthroplasty. PMID:18765029

  2. Impact of socioeconomic factors on informed decision making and treatment choice in patients with hip and knee OA.

    PubMed

    Youm, Jiwon; Chan, Vanessa; Belkora, Jeffrey; Bozic, Kevin J

    2015-02-01

    It is unclear how socioeconomic (SES) status influences the effectiveness of shared decision making (SDM) tools. The purpose of this study was to assess the impact of SES on the utility of SDM tools among patients with hip and knee osteoarthritis (OA). We performed a secondary analysis of data from a randomized controlled trial of 123 patients with hip or knee OA. Higher education and higher income were independently associated with higher knowledge survey scores. Patients with private insurance were 2.7 times more likely than patients with Medicare to arrive at a decision after the initial office visit. Higher education was associated with lower odds of choosing surgery, even after adjusting for knowledge. Patient knowledge of their medical condition and treatment options varies with SES. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. The Impact of Knee Injury History on Health-Related Quality of Life in Adolescent Athletes.

    PubMed

    Lam, Kenneth C; Markbreiter, Jessica G

    2017-10-16

    Current evidence suggests that, despite returning to full participation, physically active adults with a previous knee injury experience lower health-related quality of life (HRQOL) than those with no knee injury history. It is unknown if this relationship is present in adolescent athletes. To determine the impact of knee injury history on HRQOL in adolescent athletes who were medically cleared for full participation. Cross-sectional. Athletic training clinics. A convenience sample of 183 adolescent athletes, who were medically cleared for full participation, were grouped by self-report of a previous knee injury: positive knee injury history [HIS] (n=36, age=15.7+1.35 years, height=168.0+11.9 cm; weight=71.8+11.9 kg) and no knee injury history [NO-HIS] (n=147, age=15.5+1.4 years, height=166.0+10.5 cm, weight=67.6+14.6 kg). Participants completed the pediatric version of the International Knee Documentation Committee form (Pedi-IKDC) and Pediatric Quality of Life Inventory (PedsQL) during their preparticipation examination. Generalized linear models were used to compare group differences for the total and subscale scores of the Pedi-IKDC and PedsQL. Main effects of injury group indicated that the HIS group reported significantly lower scores than the NO-HIS group for the Pedi-IKDC total score (p<.001; HIS=79.2±21.7, NO-HIS=95.8±8.6) and for the PedsQL total (p=.001 HIS=85.7±10.9, NO-HIS=90.9±7.3), physical functioning (p=.002; HIS=86.7±13.6, NO-HIS=92.1±8.2), school functioning (p=.01; HIS=80.6±12.4, NO-HIS=86.8±12.2), and social functioning (p=.01; HIS=89.3+12.4, NO-HIS=94.6+8.9) scores. No group differences were reported for the emotional functioning subscale (p=.13; HIS=85.7±17.7, NO-HIS=89.7±13.1). No interactions or main effects of sex were reported (p>.05). Our findings suggest that, despite returning to full sport participation, adolescent athletes with a previous knee injury generally experience lower HRQOL than their peers with no knee injury history, specifically for knee-specific HRQOL, physical functioning, school functioning and social functioning. Our results are similar to previous findings reported in collegiate athletes and military cadets.

  4. Isokinetic and isometric strength in osteoarthrosis of the knee. A comparative study with healthy women.

    PubMed

    Tan, J; Balci, N; Sepici, V; Gener, F A

    1995-01-01

    Dynamic stability of the knee joint depends on the appropriate strength ratio of quadriceps and hamstring muscles. The purpose of this investigation was to determine the maximum peak torque (MPT) and MPT ratios of hamstrings to quadriceps (H/Q) muscles in patients with knee osteoarthritis (OA). Two groups of patients were included in the study. The first group consisted of 30 patients (Group A) with the clinical and radiologic findings of knee OA. The second group consisted of 30 patients (Group B) exhibiting knee joint pain without roentgenologic findings of knee OA. The findings of two patient groups were compared with each other and also with 30 healthy subjects (Group C). Isokinetic (at 60 degrees/s and at 180 degrees/s) and isometric (at 30 degrees and at 60 degrees of knee flexion) tests were performed by the rate-limiting isokinetic dynamometer system. Isokinetic and isometric MPT loss of knee flexors and extensors was found in both patient groups with respect to controls, but MPT ratios of H/Q muscles did not show a statistically significant difference compared with the control group. This may be related to the equal strength loss of knee flexors and knee extensors in patients with knee OA. It is concluded that strengthening exercises of hamstring muscles is as important as quadriceps strengthening in rehabilitation of knee OA.

  5. Validity and reliability of an instrumented leg-extension machine for measuring isometric muscle strength of the knee extensors.

    PubMed

    Ruschel, Caroline; Haupenthal, Alessandro; Jacomel, Gabriel Fernandes; Fontana, Heiliane de Brito; Santos, Daniela Pacheco dos; Scoz, Robson Dias; Roesler, Helio

    2015-05-20

    Isometric muscle strength of knee extensors has been assessed for estimating performance, evaluating progress during physical training, and investigating the relationship between isometric and dynamic/functional performance. To assess the validity and reliability of an adapted leg-extension machine for measuring isometric knee extensor force. Validity (concurrent approach) and reliability (test and test-retest approach) study. University laboratory. 70 healthy men and women aged between 20 and 30 y (39 in the validity study and 31 in the reliability study). Intraclass correlation coefficient (ICC) values calculated for the maximum voluntary isometric torque of knee extensors at 30°, 60°, and 90°, measured with the prototype and with an isokinetic dynamometer (ICC2,1, validity study) and measured with the prototype in test and retest sessions, scheduled from 48 h to 72 h apart (ICC1,1, reliability study). In the validity analysis, the prototype showed good agreement for measurements at 30° (ICC2,1 = .75, SEM = 18.2 Nm) and excellent agreement for measurements at 60° (ICC2,1 = .93, SEM = 9.6 Nm) and at 90° (ICC2,1 = .94, SEM = 8.9 Nm). Regarding the reliability analysis, between-days' ICC1,1 were good to excellent, ranging from .88 to .93. Standard error of measurement and minimal detectable difference based on test-retest ranged from 11.7 Nm to 18.1 Nm and 32.5 Nm to 50.1 Nm, respectively, for the 3 analyzed knee angles. The analysis of validity and repeatability of the prototype for measuring isometric muscle strength has shown to be good or excellent, depending on the knee joint angle analyzed. The new instrument, which presents a relative low cost and easiness of transportation when compared with an isokinetic dynamometer, is valid and provides consistent data concerning isometric strength of knee extensors and, for this reason, can be used for practical, clinical, and research purposes.

  6. RELATIONSHIP BETWEEN ISOKINETIC KNEE STRENGTH AND JUMP CHARACTERISTICS FOLLOWING ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION.

    PubMed

    Laudner, Kevin; Evans, Daniel; Wong, Regan; Allen, Aaron; Kirsch, Tom; Long, Brian; Meister, Keith

    2015-06-01

    Clinicians are often challenged when making return-to-play decisions following anterior cruciate ligament reconstruction (ACL-R). Isokinetic strength and jump performance testing are common tools used to make this decision. Unfortunately, vertical jump performance standards have not been clearly established and many clinicians do not have access to isokinetic testing equipment. To establish normative jump and strength characteristics in ACL-R patients cleared by an orthopedic physician to return-to-play and to determine if relationships exist between knee isokinetic strength measurements and jump characteristics described using an electronic jump map system. Descriptive laboratory study. Thirty-three ACL-R patients who had been cleared to return to athletic competition participated in this study. Twenty-six of these ACL-R participants were also matched to 26 asymptomatic athletes based on sex, limb, height, and mass to determine isokinetic strength and jump characteristic differences between groups. Jump tests consisted of single leg vertical, double leg vertical, and a 4-jump single leg vertical jump assessed using an electronic jump mat system. Independent t-tests were used to determine differences between groups and multiple regression analyses were used to identify any relationships between jump performance and knee strength (p<0.05). The ACL-R group had lower vertical jump capabilities and some bilateral knee strength deficiencies compared to the matched control group. The ACL-R group also showed several moderate-to-strong positive relationships for both knee extension and flexion strength with several jump performance characteristics, such as single and double leg vertical jump height. The current results indicate that ACL-R patients present with several knee strength and vertical jump differences compared to a matched control group at the time of return-to-play. Also, ACL-R patient's performance on an electronic jump mat system is strongly related to isokinetic knee strength measures. 2b.

  7. Instruction of jump-landing technique using videotape feedback: altering lower extremity motion patterns.

    PubMed

    Oñate, James A; Guskiewicz, Kevin M; Marshall, Stephen W; Giuliani, Carol; Yu, Bing; Garrett, William E

    2005-06-01

    Anterior cruciate ligament injury prevention programs have used videotapes of jump-landing technique as a key instructional component to improve landing performance. All videotape feedback model groups will increase knee flexion angles at initial contact and overall knee flexion motion and decrease peak vertical ground reaction forces and peak proximal anterior tibial shear forces to a greater extent than will a nonfeedback group. The secondary hypothesis is that the videotape feedback using the combination of the expert and self models will create the greatest change in each variable. Controlled laboratory study. Knee kinematics and kinetics of college-aged recreational athletes randomly placed in 3 different videotape feedback model groups (expert only, self only, combination of expert and self) and a nonfeedback group were collected while participants performed a basketball jump-landing task on 3 testing occasions. All feedback groups significantly increased knee angular displacement flexion angles [F(6,70) = 8.03, P = .001] and decreased peak vertical ground reaction forces [F(6,78) = 2.68, P = .021] during performance and retention tests. The self and combination groups significantly increased knee angular displacement flexion angles more than the control group did; the expert model group did not change significantly more than the control group did. All feedback groups and the nonfeedback group significantly reduced peak vertical forces across performance and retention tests. There were no statistically significant changes in knee flexion angle at initial ground contact (P = .111) and peak proximal anterior tibial shear forces (P = .509) for both testing sessions for each group. The use of self or combination videotape feedback is most useful for increasing knee angular displacement flexion angles and reducing peak vertical forces during landing. The use of self or combination modeling is more effective than is expert-only modeling for the implementation of instructional programs aimed at reducing the risk of jump-landing anterior cruciate ligament injuries.

  8. Bone curvature changes can predict the impact of treatment on cartilage volume loss in knee osteoarthritis: data from a 2-year clinical trial.

    PubMed

    Raynauld, Jean-Pierre; Pelletier, Jean-Pierre; Delorme, Philippe; Dodin, Pierre; Abram, François; Martel-Pelletier, Johanne

    2017-06-01

    Knee bone curvature assessed by MRI was associated with OA cartilage loss. A recent knee OA trial demonstrated the superiority of chondroitin sulfate over celecoxib (comparator) at reducing cartilage volume loss (CVL) in the medial compartment (condyle). The main objectives were to identify which baseline bone curvature regions of interest (BCROI) best associated with CVL and investigate whether baseline BCROI and 2-year change are correlated with the protective effect of chondroitin sulphate on CVL. This post hoc analysis of a clinical trial used the according-to-protocol population (chondroitin sulphate, n = 57; celecoxib, n = 63) baseline and 2-year MRI to assess bone curvature and CVL. Global optimum search identified the BCROI in the medial condyle using celecoxib as reference. Statistical analyses were performed with Pearson's correlation, Mann-Whitney U -test, Student's t -test and analysis of covariance. The BCROI including the medial posterior condyle and lateral central condyle was found to correlate best with medial condyle CVL at 2 years ( r = 0.33, P = 0.008). In patients with a baseline BCROI value less than the median (more flattened bone), chondroitin sulphate demonstrated a protective effect on CVL compared with celecoxib in the medial compartment (P = 0.037). In patients with 2-year BCROI changes greater than the median (greater severity of bone flattening), chondroitin sulphate protected against CVL in the medial compartment, condyle and central plateau (P ⩽ 0.030). This study is the first to demonstrate the feasibility and usefulness of bone curvature measurements to predict effectiveness of OA treatment on CVL. The results identify bone curvature as a potential novel biomarker for knee OA clinical trials. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  9. Association of Quadriceps Strength and Psychosocial Factors With Single-Leg Hop Performance in Patients With Meniscectomy.

    PubMed

    Hsu, Chao-Jung; George, Steven Z; Chmielewski, Terese L

    2016-12-01

    Clinicians use the single-leg hop test to assess readiness for return to sports after knee injury. Few studies have reported the results of single-leg hop testing after meniscectomy. Additionally, the contributions of impairments in quadriceps strength and psychosocial factors to single-leg hop performance are unknown. To compare single-leg hop performance (distance and landing mechanics) between limbs and to examine the association of single-leg hop performance with quadriceps strength and psychosocial factors in patients with meniscectomy. Descriptive laboratory study. A total of 22 subjects who underwent meniscectomy for traumatic meniscal tears received either standard rehabilitation alone or with additional quadriceps strengthening. Testing was conducted immediately postrehabilitation and at 1 year postsurgery. A single-leg hop test was performed bilaterally, and hop distance was used to create a hop symmetry index. Landing mechanics (peak knee flexion angle, knee extension moment, and peak vertical ground-reaction force) were analyzed with a motion-capture system and a force plate. An isokinetic dynamometer (60 deg/s) assessed knee extensor peak torque and rate of torque development (RTD 0-200ms and RTD 0-peak torque ). Questionnaires assessed fear of reinjury (Tampa Scale for Kinesiophobia [TSK-11]) and self-efficacy (Knee Activity Self-Efficacy [KASE]). Rehabilitation groups did not significantly differ in single-leg hop performance; therefore, groups were combined for further analyses. The mean hop symmetry index was 88.6% and 98.9% at postrehabilitation and 1 year postsurgery, respectively. Compared with the nonsurgical limb, the surgical limb showed decreased peak knee flexion angle at postrehabilitation and decreased knee extension moment at 1 year postsurgery. The hop symmetry index was positively associated with peak torque, RTD 0-200ms , and the KASE score at postrehabilitation. Moreover, at postrehabilitation, the peak knee flexion angle was positively associated with peak torque and RTD 0-200ms , and the knee extension moment was positively associated with RTD 0-200ms . At 1 year postsurgery, peak knee flexion angle and knee extension moment were both positively associated with peak torque, RTD 0-200ms , and RTD 0-peak torque . Although the hop symmetry index could be considered satisfactory for returning to sports, asymmetries in landing mechanics still exist in the first year postmeniscectomy. Greater quadriceps strength was associated with greater single-leg hop distance and better landing mechanics at both postrehabilitation and 1 year postsurgery. Knee activity self-efficacy was the only psychosocial factor associated with single-leg hop performance and isolated to a positive association with single-leg hop distance at postrehabilitation. Rate of development is not typically measured in the clinic but can be an additional quadriceps measure to monitor for single-leg hop performance. Quadriceps strength and psychosocial factors appear to have separate influence on single-leg hop performance after meniscectomy, which has implications for developing appropriate interventions for optimal single-leg hop performance.

  10. Association of Quadriceps Strength and Psychosocial Factors With Single-Leg Hop Performance in Patients With Meniscectomy

    PubMed Central

    Hsu, Chao-Jung; George, Steven Z.; Chmielewski, Terese L.

    2016-01-01

    Background: Clinicians use the single-leg hop test to assess readiness for return to sports after knee injury. Few studies have reported the results of single-leg hop testing after meniscectomy. Additionally, the contributions of impairments in quadriceps strength and psychosocial factors to single-leg hop performance are unknown. Purpose: To compare single-leg hop performance (distance and landing mechanics) between limbs and to examine the association of single-leg hop performance with quadriceps strength and psychosocial factors in patients with meniscectomy. Study Design: Descriptive laboratory study. Methods: A total of 22 subjects who underwent meniscectomy for traumatic meniscal tears received either standard rehabilitation alone or with additional quadriceps strengthening. Testing was conducted immediately postrehabilitation and at 1 year postsurgery. A single-leg hop test was performed bilaterally, and hop distance was used to create a hop symmetry index. Landing mechanics (peak knee flexion angle, knee extension moment, and peak vertical ground-reaction force) were analyzed with a motion-capture system and a force plate. An isokinetic dynamometer (60 deg/s) assessed knee extensor peak torque and rate of torque development (RTD0-200ms and RTD0–peak torque). Questionnaires assessed fear of reinjury (Tampa Scale for Kinesiophobia [TSK-11]) and self-efficacy (Knee Activity Self-Efficacy [KASE]). Results: Rehabilitation groups did not significantly differ in single-leg hop performance; therefore, groups were combined for further analyses. The mean hop symmetry index was 88.6% and 98.9% at postrehabilitation and 1 year postsurgery, respectively. Compared with the nonsurgical limb, the surgical limb showed decreased peak knee flexion angle at postrehabilitation and decreased knee extension moment at 1 year postsurgery. The hop symmetry index was positively associated with peak torque, RTD0-200ms, and the KASE score at postrehabilitation. Moreover, at postrehabilitation, the peak knee flexion angle was positively associated with peak torque and RTD0-200ms, and the knee extension moment was positively associated with RTD0-200ms. At 1 year postsurgery, peak knee flexion angle and knee extension moment were both positively associated with peak torque, RTD0-200ms, and RTD0–peak torque. Conclusion: Although the hop symmetry index could be considered satisfactory for returning to sports, asymmetries in landing mechanics still exist in the first year postmeniscectomy. Greater quadriceps strength was associated with greater single-leg hop distance and better landing mechanics at both postrehabilitation and 1 year postsurgery. Knee activity self-efficacy was the only psychosocial factor associated with single-leg hop performance and isolated to a positive association with single-leg hop distance at postrehabilitation. Clinical Relevance: Rate of development is not typically measured in the clinic but can be an additional quadriceps measure to monitor for single-leg hop performance. Quadriceps strength and psychosocial factors appear to have separate influence on single-leg hop performance after meniscectomy, which has implications for developing appropriate interventions for optimal single-leg hop performance. PMID:28210647

  11. Magnetostrictive energy generator for harvesting the rotation of human knee joint

    NASA Astrophysics Data System (ADS)

    Yan, Baiping; Zhang, Chengming; Li, Liyi

    2018-05-01

    This paper presents the design and fabrication of a rotary-impact magnetostrictive energy generator, used to harvest the rotation of human knee joint. The harvester consists of twelve movable Terfenol-D rods, surrounded by the picked up coils respectively, and alternate permanent magnet (PM) array sandwiched in each part of the shell. Rotational electromagnetic power generating effect and impacted magnetostrictive power generating effect are designed in the harvester. Modeling and simulation are used to validate the concept. Then, magnetic field and leakage of the harvester are analyzed, electromagnetic force in the harvester is simulated. A prototype of harvester is fabricated, and subjected to the experimental characterization. It can be concluded that huge induced voltage generated in the short-time impact situation and that induced voltage in the harvester can reach up to 60-80 volts at 0.91Hz low frequency rotation. Also, the presented harvester has good harvesting effects at low frequency human walking and periodic swing crus situation, which are suitable to be used for future researches of wearable knee joint applications.

  12. The effect of exercise therapy on knee osteoarthritis: a randomized clinical trial

    PubMed Central

    Nejati, Parisa; Farzinmehr, Azizeh; Moradi-Lakeh, Maziar

    2015-01-01

    Background: Knee osteoarthritis (OA) is the most common musculoskeletal disease among old individuals which affects ability for sitting on the chair, standing, walking and climbing stairs. Our objective was to investigate the short and long-term effects of the most simple and the least expensive exercise protocols in combination to conventional conservative therapy for knee OA. Methods: It was a single blind RCT study with a 12-months follow-up. Totally, 56 patients with knee OA were assigned into 2 random groups. The patients in exercise group received exercise for knee muscles in combination with non-steroid anti-inflammatory drugs (NSAIDs) and 10 sessions acupuncture and physiotherapy modalities. Non-exercise group received similar treatments except exercise program. The changes in patients’ pain and functional status were evaluated by visual analog scale (VAS), knee and osteoarthritis outcome score (KOOS) questionnaire and functional tests (4 steps, 5 sit up, and 6 min walk test) before and after treatment (1 and 3 months after intervention), and 1 year later at the follow-up. Results: The results showed that the patients with knee OA in exercise group had significant improvement in pain, disability, walking, stair climbing, and sit up speed after treatment at first and second follow-up when compared with their initial status and when compared with non-exercise group. At third follow up (1 year later) there was significant difference between groups in VAS and in three items of KOOS questionnaire in functional status. Conclusion: Non aerobic exercises for muscles around knee can augment the effect of other therapeutic interventions like medical therapy, acupuncture, and modalities for knee OA. PMID:26034739

  13. The immediate effect of patellar tendon strap on weight-bearing asymmetry during squatting in patients with unilateral knee osteoarthritis: A pilot study.

    PubMed

    Demirbüken, İlkşan; Özyürek, Seher; Angın, Salih

    2016-12-01

    Knee osteoarthritis has commonly been associated with a symptom of pain resulting in an inter-limb weight-bearing asymmetry during functional tasks. Patellar tendon strap is one of the non-pharmacologic interventions to alleviate knee pain. To investigate the immediate effect of a patellar tendon strap on weight-bearing asymmetry during squatting in people with unilateral knee osteoarthritis. Cross-sectional study. Ten patients with unilateral knee osteoarthritis and 10 healthy subjects were included in the study. Weight-bearing asymmetry of patients was assessed using a weight-bearing squat test during squatting at 30° and 60° both with and without patellar tendon strap. Pain intensity was assessed during squatting in unstrapped and strapped conditions with Visual Analog Scale. The decrease in weight-bearing asymmetry values immediately after wearing patellar tendon strap during 30° (p = 0.006) and 60° (p = 0.011) of squatting tests was significantly higher in knee osteoarthritis patients than in healthy subjects. Reported pain intensity was similar in unstrapped and strapped conditions (p = 0.066). The results of this study showed improved inter-limb weight-bearing symmetry during squatting. Further research with larger sample sizes investigating the effect of patellar tendon strap on weight-bearing asymmetry during functional activities in people with knee osteoarthritis is warranted. Patellar tendon straps (easily fit and cheap unlike knee braces) had more improvements in inter-limb weight-bearing symmetry during squatting in people with knee osteoarthritis compared to healthy subjects. This study is a new insight for future studies to investigate clinical benefits of wearing patellar tendon straps in this population. © The International Society for Prosthetics and Orthotics 2015.

  14. Bracing of the Reconstructed and Osteoarthritic Knee during High Dynamic Load Tasks.

    PubMed

    Hart, Harvi F; Crossley, Kay M; Collins, Natalie J; Ackland, David C

    2017-06-01

    Lateral compartment osteoarthritis accompanied by abnormal knee biomechanics is frequently reported in individuals with knee osteoarthritis after anterior cruciate ligament reconstruction (ACLR). The aim of this study was to evaluate changes in knee biomechanics produced by an adjusted and unadjusted varus knee brace during high dynamic loading activities in individuals with lateral knee osteoarthritis after ACLR and valgus malalignment. Nineteen participants who had undergone ACLR 5 to 20 yr previously and had symptomatic and radiographic lateral knee osteoarthritis with valgus malalignment were assessed. Quantitative motion analysis experiments were conducted during hopping, stair ascent, and descent under three test conditions: (i) no brace, (ii) unadjusted brace with sagittal plane support and neutral frontal plane alignment, and (iii) adjusted brace with sagittal plane support and varus realignment (valgus to neutral). Sagittal, frontal, and transverse plane knee kinematics, external joint moment, and angular impulse data were calculated. Relative to an unbraced knee, braced conditions significantly increased knee flexion and adduction angles during hopping (P = 0.003 and P = 0.005; respectively), stair ascent (P = 0.003 and P < 0.001, respectively), and descent (P = 0.009 and P < 0.001, respectively). In addition, the brace conditions increased knee flexion (P < 0.001) and adduction (P = 0.001) angular impulses and knee stiffness (P < 0.001) during hopping, as well as increased knee adduction moments during stair ascent (P = 0.008) and flexion moments during stair descent (P = 0.006). There were no significant differences between the adjusted and the unadjusted brace conditions (P > 0.05). A knee brace, with or without varus alignment, can modulate knee kinematics and external joint moments during hopping, stairs ascent, and descent in individuals with predominant lateral knee osteoarthritis after ACLR. Longer-term use of a brace may have implications in slowing osteoarthritis progression.

  15. Posterior root tear of the medial meniscus in multiple knee ligament injuries.

    PubMed

    Kim, Young Jae; Kim, Jin Goo; Chang, Seok Hwan; Shim, Jae Chan; Kim, Sang Bum; Lee, Mi Young

    2010-10-01

    The purposes of the present study were to examine the frequency and characteristics of root tears of the medial meniscus associated with ligament injuries of the knee and to evaluate the effectiveness of pull-out repair for restoring meniscus function. We retrospectively analyzed the 9 patients (10 knees) with posterior root tears of the medial meniscus and ligament injuries of the knee treated between August 2004 and February 2007. All the patients were male, with average age of 29.8 years, and the mean follow-up period was 29.7 months. The pull-out suture technique was used to repair the root tears. Clinical outcomes were evaluated using the Lysholm, IKDC, and Tegner scores, as well as the McMurray and Apley tests. The mean follow-up period was 41.1 months (range, 30 to 63 months). The incidence of root tears of the medial meniscus with ligament injuries was 2.74% (10 cases in 365 ligament surgeries). All clinical results showed significant improvement. At the final follow-up, McMurray test showed one positive and nine negative cases, and the Apley test revealed two positive and eight negative cases. There were no positive findings in anterior drawer test, posterior drawer test, valgus and varus stress test, and posterolateral instability test. Healing of the root tear was confirmed by arthroscopy in five patients and by MR in four patients. Root tears of the medial meniscus may occur in multiple knee ligament injuries. It is important not to miss them. Our results indicate that pull-out repair provides satisfactory results and evidence of healing. Copyright 2009 Elsevier B.V. All rights reserved.

  16. Validity and Responsiveness of the Two-Minute Walk Test for Measuring Functional Recovery After Total Knee Arthroplasty.

    PubMed

    Unnanuntana, Aasis; Ruangsomboon, Pakpoom; Keesukpunt, Worawut

    2018-06-01

    The 2-minute walk test (2mwt) is a performance-based test that evaluates functional recovery after total knee arthroplasty (TKA). This study evaluated its validity compared with the modified Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS), modified Knee Score, Numerical Pain Rating Scale, and Timed Up and Go test, and its responsiveness in assessing functional recovery in TKA patients. This prospective cohort study included 162 patients undergoing primary TKA between 2013 and 2015. We used patient-reported outcome measures (modified WOMAC, OKS, modified Knee Score, Numerical Pain Rating Scale) and performance-based tests (2mwt and Timed Up and Go test) at baseline and 3, 6, and 12 months postoperatively. The construct validity of 2mwt was determined between the 2mwt distances walked and other outcome measurements. To assess responsiveness, effect size and standardized response mean were analyzed. Minimal clinically important difference of 2mwt at 12 months after TKA was also calculated. All outcome measurements improved significantly from baseline to 3, 6, and 12 months postoperatively. Bivariate analysis revealed mild to moderate associations between the 2mwt and modified WOMAC function subscales, and moderate to strong associations with OKS. Mild to moderate correlations were found for pain and stiffness between 2mwt and other outcome measurements. The effect size and standardized response mean at 12 months were large, with a minimal clinically important difference of 12.7 m. 2mwt is a validated performance-based test with responsiveness properties. Being simple and easy to perform, it can be used routinely in clinical practice to evaluate functional recovery after TKA. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  17. Knock knee and the gait of six-year-old children.

    PubMed

    Pretkiewicz-Abacjew, E

    2003-06-01

    Knock knee (genu valgum) interferes with the locomotive and supporting function of the lower limb. In static conditions the load-bearing axis of the valgus limb is displaced laterally in relation to the middle of the joint, causing the knee joint, the ankle joint, and the foot as a whole to be weighted in the wrong way. The purpose of this work is to examine the influence of knock knee on gait kinematics. The gait of twenty-two 6-year-old children of both sexes in whom knock knee had been medically diagnosed was compared with the gait of 33 children of the same age whose knee joints conformed to the norm in formation and position. Gait was recorded separately for the sagittal and the frontal planes, using a video-computer system. The results of the examination indicated statistically significant differences in the gait of the two groups of children. These differences related mainly to the time features of gait and to data on the angles in the knee and ankle joints. Although the results obtained for other features of gait did not reveal statistical differences, these did indicate that the children with knock knee walked more slowly and with a lower cadence. The results indicate that knock knee in 6-year-old children has an adverse impact on the mechanics of the lower limb joints in gait and causes a deterioration in gait quality. Thus knock knee in children should not be treated merely as a superficial defect but should be subject to therapy and, more importantly, taken into account when introducing children to early sports training.

  18. Comparative Study of Assisted Ambulation and Perceived Exertion With the Wheeled Knee Walker and Axillary Crutches in Healthy Subjects.

    PubMed

    Kocher, Benjamin K; Chalupa, Robyn L; Lopez, Donna M; Kirk, Kevin L

    2016-11-01

    Functional limitations after lower extremity surgery often require the use of an assistive device for ambulation during rehabilitation and recovery. There are no known objective data evaluating the wheeled knee walker as an assistive device for protected ambulation. The purpose of this study was to compare assisted ambulation and perceived exertion with the wheeled knee walker and the axillary crutches in healthy participants. A prospective, randomized crossover study was performed using 24 healthy volunteers. Each participant performed a 6-minute walk test (6MWT) using each assistive device in a crossover manner. Preactivity and postactivity heart rates were recorded. The self-selected walking velocity (SSWV) was calculated and the participant's rating of perceived exertion was recorded using the OMNI Rating of Perceived Exertion (OMNI-RPE). Participant's preference for assistive device was identified. The 6MWT, SSWV, and the Omni-RPE were evaluated using paired t tests and determined to be statistically significant for the wheeled knee walker compared with axillary crutches. Evaluation of the preactivity and postactivity heart rates demonstrated a statistically significant difference for the wheeled knee walker compared with axillary crutches. The wheeled knee walker was preferred by 88% of participants. The wheeled knee walker provided increased assisted ambulation and had a lower rating of perceived exertion than axillary crutches on level surfaces in healthy participants. Level III, comparative study. © The Author(s) 2016.

  19. Nonparetic Knee Extensor Strength Is the Determinant of Exercise Capacity of Community-Dwelling Stroke Survivors

    PubMed Central

    Wang, Wei-Te; Huang, Ling-Tzu; Chou, Ya-Hui; Wei, Ta-Sen; Lin, Chung-Che

    2014-01-01

    Objective. To investigate the relationship among walking speed, exercise capacity, and leg strength in community dwelling stroke subjects and to evaluate which one was the leading determinant factor of them. Design. This is a descriptive, cross-sectional study. Thirty-five chronic stroke patients who were able to walk independently in their community were enrolled. Walking speed was evaluated by using the 12-meter walking test. A maximal exercise test was used to determine the stroke subjects' exercise capacity. Knee extensor strength, measured as isokinetic torque, was assessed by isokinetic dynamometer. Results. The main walking speed of our subjects was 0.52 m/s. Peak oxygen uptake (VO2 peak) was 1.21 ± 0.43 L/min. Knee extensor strength, no matter whether paretic or nonparetic side, was significantly correlated to 12-meter walking speed and exercise capacity. Linear regression also showed the strength of the affected knee extensor was the determinant of walking speed and that of the nonparetic knee extensor was the determinant of exercise capacity in community dwelling stroke subjects. Conclusions. Walking speed and peak oxygen uptake were markedly decreased after stroke. Knee extensor strength of nonparetic leg was the most important determinant of exercise capacity of the community-dwelling stroke subjects. Knee extensor strengthening should be emphasized to help stroke patient to achieve optimal community living. PMID:25197712

  20. Nonparetic knee extensor strength is the determinant of exercise capacity of community-dwelling stroke survivors.

    PubMed

    Wang, Wei-Te; Huang, Ling-Tzu; Chou, Ya-Hui; Wei, Ta-Sen; Lin, Chung-Che

    2014-01-01

    To investigate the relationship among walking speed, exercise capacity, and leg strength in community dwelling stroke subjects and to evaluate which one was the leading determinant factor of them. This is a descriptive, cross-sectional study. Thirty-five chronic stroke patients who were able to walk independently in their community were enrolled. Walking speed was evaluated by using the 12-meter walking test. A maximal exercise test was used to determine the stroke subjects' exercise capacity. Knee extensor strength, measured as isokinetic torque, was assessed by isokinetic dynamometer. The main walking speed of our subjects was 0.52 m/s. Peak oxygen uptake (VO₂ peak) was 1.21 ± 0.43 L/min. Knee extensor strength, no matter whether paretic or nonparetic side, was significantly correlated to 12-meter walking speed and exercise capacity. Linear regression also showed the strength of the affected knee extensor was the determinant of walking speed and that of the nonparetic knee extensor was the determinant of exercise capacity in community dwelling stroke subjects. Walking speed and peak oxygen uptake were markedly decreased after stroke. Knee extensor strength of nonparetic leg was the most important determinant of exercise capacity of the community-dwelling stroke subjects. Knee extensor strengthening should be emphasized to help stroke patient to achieve optimal community living.

  1. Do radiographic disease and pain account for why people with or at high risk of knee osteoarthritis do not meet physical activity guidelines?

    PubMed

    White, Daniel K; Tudor-Locke, Catrine; Felson, David T; Gross, K Douglas; Niu, Jingbo; Nevitt, Michael; Lewis, Cora E; Torner, James; Neogi, Tuhina

    2013-01-01

    Knee osteoarthritis (OA) and pain are assumed to be barriers to meeting physical activity guidelines, but this has not been formally evaluated. The purpose of this study was to determine the proportions of people with and those without knee OA and knee pain who meet recommended physical activity levels through walking. We performed a cross-sectional analysis of community-dwelling adults from the Multicenter Osteoarthritis Study who had or who were at high risk of knee OA. Participants wore a StepWatch activity monitor to record steps per day for 7 days. The proportion of participants who met the recommended physical activity levels was defined as those accumulating≥150 minutes per week at ≥100 steps per minute in bouts lasting ≥10 minutes. These proportions were also determined for those with and those without knee OA, as classified by radiography and by severity of knee pain. Of the 1,788 study participants (mean±SD age 67.2±7.7 years, mean±SD body mass index 30.7±6.0 kg/m2, 60% women), lower overall percentages of participants with radiographic knee OA and knee pain met recommended physical activity levels. However, these differences were not statistically significant between those with and those without knee OA; 7.3% and 10.1% of men (P=0.34) and 6.3% and 7.8% of women (P=0.51), respectively, met recommended physical activity levels. Similarly, for those with moderate/severe knee pain and those with no knee pain, 12.9% and 10.9% of men (P=0.74) and 6.7% and 11.0% of women (P=0.40), respectively, met recommended physical activity levels. Disease and pain have little impact on achieving recommended physical activity levels among people with or at high risk of knee OA. Copyright © 2013 by the American College of Rheumatology.

  2. Clinical descriptors for the recognition of central sensitization pain in patients with knee osteoarthritis.

    PubMed

    Lluch, Enrique; Nijs, Jo; Courtney, Carol A; Rebbeck, Trudy; Wylde, Vikki; Baert, Isabel; Wideman, Timothy H; Howells, Nick; Skou, Søren T

    2017-08-02

    Despite growing awareness of the contribution of central pain mechanisms to knee osteoarthritis pain in a subgroup of patients, routine evaluation of central sensitization is yet to be incorporated into clinical practice. The objective of this perspective is to design a set of clinical descriptors for the recognition of central sensitization in patients with knee osteoarthritis that can be implemented in clinical practice. A narrative review of original research papers was conducted by nine clinicians and researchers from seven different countries to reach agreement on clinically relevant descriptors. It is proposed that identification of a dominance of central sensitization pain is based on descriptors derived from the subjective assessment and the physical examination. In the former, clinicians are recommended to inquire about intensity and duration of pain and its association with structural joint changes, pain distribution, behavior of knee pain, presence of neuropathic-like or centrally mediated symptoms and responsiveness to previous treatment. The latter includes assessment of response to clinical test, mechanical hyperalgesia and allodynia, thermal hyperalgesia, hypoesthesia and reduced vibration sense. This article describes a set of clinically relevant descriptors that might indicate the presence of central sensitization in patients with knee osteoarthritis in clinical practice. Although based on research data, the descriptors proposed in this review require experimental testing in future studies. Implications for Rehabilitation Laboratory evaluation of central sensitization for people with knee osteoarthritis is yet to be incorporated into clinical practice. A set of clinical indicators for the recognition of central sensitization in patients with knee osteoarthritis is proposed. Although based on research data, the clinical indicators proposed require further experimental testing of psychometric properties.

  3. Translation, Cross-Cultural Adaptation, and Validation of the Activity Rating Scale for Disorders of the Knee.

    PubMed

    Flosadottir, Vala; Roos, Ewa M; Ageberg, Eva

    2017-09-01

    The Activity Rating Scale (ARS) for disorders of the knee evaluates the level of activity by the frequency of participation in 4 separate activities with high demands on knee function, with a score ranging from 0 (none) to 16 (pivoting activities 4 times/wk). To translate and cross-culturally adapt the ARS into Swedish and to assess measurement properties of the Swedish version of the ARS. Cohort study (diagnosis); Level of evidence, 2. The COSMIN guidelines were followed. Participants (N = 100 [55 women]; mean age, 27 years) who were undergoing rehabilitation for a knee injury completed the ARS twice for test-retest reliability. The Knee injury and Osteoarthritis Outcome Score (KOOS), Tegner Activity Scale (TAS), and modernized Saltin-Grimby Physical Activity Level Scale (SGPALS) were administered at baseline to validate the ARS. Construct validity and responsiveness of the ARS were evaluated by testing predefined hypotheses regarding correlations between the ARS, KOOS, TAS, and SGPALS. The Cronbach alpha, intraclass correlation coefficients, absolute reliability, standard error of measurement, smallest detectable change, and Spearman rank-order correlation coefficients were calculated. The ARS showed good internal consistency (α ≈ 0.96), good test-retest reliability (intraclass correlation coefficient >0.9), and no systematic bias between measurements. The standard error of measurement was less than 2 points, and the smallest detectable change was less than 1 point at the group level and less than 5 points at the individual level. More than 75% of the hypotheses were confirmed, indicating good construct validity and good responsiveness of the ARS. The Swedish version of the ARS is valid, reliable, and responsive for evaluating the level of activity based on the frequency of participation in high-demand knee sports activities in young adults with a knee injury.

  4. Exercise-induced Hypoalgesia in People With Knee Osteoarthritis With Normal and Abnormal Conditioned Pain Modulation.

    PubMed

    Fingleton, Caitríona; Smart, Keith M; Doody, Catherine M

    2017-05-01

    Normal efficiency of exercise-induced hypoalgesia (EIH) has been demonstrated in people with knee osteoarthritis (OA), while recent evidence suggests that EIH may be associated with features of pain sensitization such as abnormal conditioned pain modulation (CPM). The aim of this study was to investigate whether people with knee OA with abnormal CPM have dysfunctional EIH compared with those with normal CPM and pain-free controls. Forty peoples with knee OA were subdivided into groups with abnormal and normal CPM, as determined by a decrease/increase in pressure pain thresholds (PPTs) following the cold pressor test. Abnormal CPM (n=19), normal CPM (n=21), and control participants (n=20) underwent PPT testing before, during, and after aerobic and isometric exercise protocols. Between-group differences were analyzed using repeated-measures analysis of variance and within-group differences were analyzed using Wilcoxon signed-rank tests. Significant differences were demonstrated between groups for changes in PPTs postaerobic (F2,55=4.860; P=0.011) and isometric (F2,57=4.727; P=0.013) exercise, with significant decreases in PPTs demonstrated during and postexercise in the abnormal CPM group (P<0.05), and significant increases in PPTs shown during and postexercise in the normal CPM and control groups (P<0.05). Results are suggestive of dysfunctional EIH in response to aerobic and isometric exercise in knee OA patients with abnormal CPM, and normal function of EIH in knee OA patients with an efficient CPM response. Identification of people with knee OA with inefficient endogenous pain modulation may allow for a more individualized and graded approach to exercises in these individuals.

  5. Vitamin D status and physical function in older Finnish people: A one-year follow-up study.

    PubMed

    Salminen, Marika; Saaristo, Pilvi; Salonoja, Maritta; Vaapio, Sari; Vahlberg, Tero; Lamberg-Allardt, Christel; Aarnio, Pertti; Kivelä, Sirkka-Liisa

    2015-01-01

    The aim was to describe vitamin D status and its association with changes in PF during 12 months in Finnish community-dwelling elderly (≥65 years). Baseline serum 25-hydroxyvitamin D (25OHD) concentration was measured by enzymeimmunoassay, and participants (n=518) were divided according to 25OHD to three groups (I <50 nmol/l, II 50-74.9 nmol/l, and III ≥75 nmol/l). PF (maximal isometric extension strength of right and left knee, and time in five-repetition sit-to-stand test (5STS) and 10-m walking test) was measured at baseline and after 12 months. 25OHD deficiency (<50 nmol/l) was found in 20.5% of the participants. During a 12-month follow-up, differences in changes in knee extensor strength of right (p=0.044) and left (p=0.010) lower extremity and in 10-m walking test (p=.040) between the groups were significant. According to further pairwise comparisons these differences were between groups I and III (right knee, p=0.036; left knee, p=0.009; 10-m walk, p=0.044), with the exception of left knee extensor strength in which there were also significant difference between groups I and II (p=0.039). All significant differences in changes were in favour of group II or III. Significant differences in changes in knee extensor strengths maintained after adjustments for group (intervention/control), parathyroid hormone, and baseline level of knee extensor strength. Prospective analyses showed low 25OHD concentrations (<50 nmol/l) to be associated with deterioration in PF during 12 months compared with high 25OHD concentrations (≥75 nmol/l). Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Knee pain and future self-reliance in older adults: evidence from a community-based 3-year cohort study in Japan.

    PubMed

    Nishiwaki, Yuji; Michikawa, Takehiro; Yamada, Mutsuko; Eto, Norihito; Takebayashi, Toru

    2011-01-01

    Although knee pain is common in older persons and can cause ambulatory limitation, its impact on self-reliance has rarely been examined in Japan, particularly in a community setting. The aim of this 3-year cohort study was to investigate the association of knee pain with dependence in activities of daily living (ADL) and mortality in community-dwelling older Japanese adults. In 2005, presence of knee pain was assessed by a home visit survey of 1391 older adults aged 65 years or older (participation proportion = 97.3%). A total of 1265 participants who were ADL-independent at baseline were followed for 3 years, and information on outcomes, namely death and dependence in ADL, was collected. Participants who always had knee pain were more likely to become dependent in ADL than those who reported no knee pain (multivariate-adjusted OR, 1.98; 95% CI, 1.03-3.83); however, always having knee pain was not associated with mortality or a composite outcome of ADL dependence and death. Further analyses of each component of ADL dependence revealed that knee pain was associated with a need for assistance at home (long-term care eligibility, bathing, dressing, and transferring), but not with institutionalization. The participants were highly representative of the target population and the rate of follow-up was almost perfect (99.4%). The results suggest that knee pain is associated with future dependence in ADL, particularly a need for assistance at home.

  7. Acute Lower Extremity Running Kinematics After a Hamstring Stretch

    PubMed Central

    Davis Hammonds, Autumn L.; Laudner, Kevin G.; McCaw, Steve; McLoda, Todd A.

    2012-01-01

    Context: Limited passive hamstring flexibility might affect kinematics, performance, and injury risk during running. Pre-activity static straight-leg raise stretching often is used to gain passive hamstring flexibility. Objective: To investigate the acute effects of a single session of passive hamstring stretching on pelvic, hip, and knee kinematics during the swing phase of running. Design: Randomized controlled clinical trial. Setting: Biomechanics research laboratory. Patients or Other Participants: Thirty-four male (age = 21.2 ± 1.4 years) and female (age = 21.3±2.0 years) recreational athletes. Intervention(s): Participants performed treadmill running pretests and posttests at 70% of their age-predicted maximum heart rate. Pelvis, hip, and knee joint angles during the swing phase of 5 consecutive gait cycles were collected using a motion analysis system. Right and left hamstrings of the intervention group participants were passively stretched 3 times for 30 seconds in random order immediately after the pretest. Control group participants performed no stretching or movement between running sessions. Main Outcome Measure(s): Six 2-way analyses of variance to determine joint angle differences between groups at maximum hip flexion and maximum knee extension with an α level of .008. Results: Flexibility increased between pretest and post-test in all participants (F1,30 = 80.61, P<.001). Anterior pelvic tilt (F1,30 = 0.73, P=.40), hip flexion (F1,30 = 2.44, P=.13), and knee extension (F1,30 = 0.06, P=.80) at maximum hip flexion were similar between groups throughout testing. Anterior pelvic tilt (F1,30 = 0.69, P=.41), hip flexion (F1,30 = 0.23, P=.64), and knee extension (F1,30 = 3.38, P=.62) at maximum knee extension were similar between groups throughout testing. Men demonstrated greater anterior pelvic tilt than women at maximum knee extension (F1,30 = 13.62, P=.001). Conclusions: A single session of 3 straight-leg raise hamstring stretches did not change pelvis, hip, or knee running kinematics. PMID:22488225

  8. Effects of off-axis elliptical training on reducing pain and improving knee function in individuals with patellofemoral pain

    PubMed Central

    Tsai, Liang-Ching; Lee, Song Joo; Yang, Aaron J.; Ren, Yupeng; Press, Joel M.; Zhang, Li-Qun

    2014-01-01

    Objective To examine whether an off-axis elliptical training program reduces pain and improves knee function in individuals with patellofemoral pain (PFP). Design Controlled laboratory study, pre-test-post-test. Setting University rehabilitation center. Participants Twelve adult subjects with PFP. Interventions Subjects with PFP completed an exercise program consisting of 18 sessions of lower extremity off-axis training using a custom-made elliptical trainer that allows frontal-plane sliding and transverse-plane pivoting of the footplates. Main Outcome Measures Changes in knee pain and function post-training and 6 weeks following training were evaluated using the Knee Injury and Osteoarthritis Outcome Score (KOOS) and International Knee Documentation Committee (IKDC) scores. Lower extremity off-axis control was assessed by pivoting and sliding instability, calculated as the root mean square (RMS) of the footplate pivoting angle and sliding distance during elliptical exercise. Subjects’ single-leg hop distance and proprioception in detecting lower extremity pivoting motion were also evaluated. Results Subjects reported significantly greater KOOS and IKDC scores (increased by 12–18 points) and hop distance (increased by 0.2 m) following training. A significant decrease in the pivoting and sliding RMS was also observed following training. Additionally, subjects with PFP demonstrated improved pivoting proprioception when tested under a minimum-weight-bearing position. Conclusions An off-axis elliptical training program was effective in enhancing lower extremity neuromuscular control on the frontal and transverse planes, reducing pain and improving knee function in persons with PFP. PMID:25591131

  9. Estimation of Electrically-Evoked Knee Torque from Mechanomyography Using Support Vector Regression.

    PubMed

    Ibitoye, Morufu Olusola; Hamzaid, Nur Azah; Abdul Wahab, Ahmad Khairi; Hasnan, Nazirah; Olatunji, Sunday Olusanya; Davis, Glen M

    2016-07-19

    The difficulty of real-time muscle force or joint torque estimation during neuromuscular electrical stimulation (NMES) in physical therapy and exercise science has motivated recent research interest in torque estimation from other muscle characteristics. This study investigated the accuracy of a computational intelligence technique for estimating NMES-evoked knee extension torque based on the Mechanomyographic signals (MMG) of contracting muscles that were recorded from eight healthy males. Simulation of the knee torque was modelled via Support Vector Regression (SVR) due to its good generalization ability in related fields. Inputs to the proposed model were MMG amplitude characteristics, the level of electrical stimulation or contraction intensity, and knee angle. Gaussian kernel function, as well as its optimal parameters were identified with the best performance measure and were applied as the SVR kernel function to build an effective knee torque estimation model. To train and test the model, the data were partitioned into training (70%) and testing (30%) subsets, respectively. The SVR estimation accuracy, based on the coefficient of determination (R²) between the actual and the estimated torque values was up to 94% and 89% during the training and testing cases, with root mean square errors (RMSE) of 9.48 and 12.95, respectively. The knee torque estimations obtained using SVR modelling agreed well with the experimental data from an isokinetic dynamometer. These findings support the realization of a closed-loop NMES system for functional tasks using MMG as the feedback signal source and an SVR algorithm for joint torque estimation.

  10. Impact of total knee replacement practice: cost effectiveness analysis of data from the Osteoarthritis Initiative.

    PubMed

    Ferket, Bart S; Feldman, Zachary; Zhou, Jing; Oei, Edwin H; Bierma-Zeinstra, Sita M A; Mazumdar, Madhu

    2017-03-28

    Objectives  To evaluate the impact of total knee replacement on quality of life in people with knee osteoarthritis and to estimate associated differences in lifetime costs and quality adjusted life years (QALYs) according to use by level of symptoms. Design  Marginal structural modeling and cost effectiveness analysis based on lifetime predictions for total knee replacement and death from population based cohort data. Setting  Data from two studies-Osteoarthritis Initiative (OAI) and the Multicenter Osteoarthritis Study (MOST)-within the US health system. Participants  4498 participants with or at high risk for knee osteoarthritis aged 45-79 from the OAI with no previous knee replacement (confirmed by baseline radiography) followed up for nine years. Validation cohort comprised 2907 patients from MOST with two year follow-up. Intervention  Scenarios ranging from current practice, defined as total knee replacement practice as performed in the OAI (with procedural rates estimated by a prediction model), to practice limited to patients with severe symptoms to no surgery. Main outcome measures  Generic (SF-12) and osteoarthritis specific quality of life measured over 96 months, model based QALYs, costs, and incremental cost effectiveness ratios over a lifetime horizon. Results  In the OAI, total knee replacement showed improvements in quality of life with small absolute changes when averaged across levels of confounding variables: 1.70 (95% uncertainty interval 0.26 to 3.57) for SF-12 physical component summary (PCS); -10.69 (-13.39 to -8.01) for Western Ontario and McMaster Universities arthritis index (WOMAC); and 9.16 (6.35 to 12.49) for knee injury and osteoarthritis outcome score (KOOS) quality of life subscale. These improvements became larger with decreasing functional status at baseline. Provision of total knee replacement to patients with SF-12 PCS scores <35 was the optimal scenario given a cost effectiveness threshold of $200 000/QALY, with cost savings of $6974 ($5789 to $8269) and a minimal loss of 0.008 (-0.056 to 0.043) QALYs compared with current practice. These findings were reproduced among patients with knee osteoarthritis from the MOST cohort and were robust against various scenarios including increased rates of total knee replacement and mortality and inclusion of non-healthcare costs but were sensitive to increased deterioration in quality of life without surgery. In a threshold analysis, total knee replacement would become cost effective in patients with SF-12 PCS scores ≤40 if the associated hospital admission costs fell below $14 000 given a cost effectiveness threshold of $200 000/QALY. Conclusion  Current practice of total knee replacement as performed in a recent US cohort of patients with knee osteoarthritis had minimal effects on quality of life and QALYs at the group level. If the procedure were restricted to more severely affected patients, its effectiveness would rise, with practice becoming economically more attractive than its current use. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  11. Relation between peak knee flexion angle and knee ankle kinetics in single-leg jump landing from running: a pilot study on male handball players to prevent ACL injury.

    PubMed

    Ameer, Mariam A; Muaidi, Qassim I

    2017-09-01

    The relationship between knee kinematics and knee-ankle kinetics during the landing phase of single leg jumping has been widely studied to identify proper strategies for preventing non-contact ACL injury. However, there is a lack of study on knee-ankle kinetics at peak knee flexion angle during jumping from running. Hence, the purpose of this study is to establish the relationship between peak knee flexion angle, knee extension moment, ankle plantar flexion moment and ground reaction force in handball players in order to protect ACL from excessive stress during single leg jumping. In addition, the study also clarifies the role of calf muscles in relieving part of ACL stresses with different knee flexion angles during landing. Fifteen active male elite handball players of Saudi Arabia have participated in this study (Age = 22.6 ± 3.5years, Height = 182 ± 3.7 cm, Weight = 87.5 ± 10.2 kg). The players performed three successful landings of single-leg jump following running a fixed distance of about 450cm. The data were collected using a 3D motion capture and analysis system (VICON). Pearson product moment correlation coefficients showed that greater peak knee flexion angle is related significantly to both lesser knee extension moment (r = -.623, P = .013) and vertical component of ground reaction force (VGRF) (r = -.688, P = .005) in landing phase. Moreover, increasing the peak knee flexion angle in landing phase tends to increase the ankle plantar flexion moment significantly (r = .832, P = .000). With an increase of the peak knee flexion angle during single leg jump landing from running, there would be less knee extension moment, low impact force and more plantar flexion moment. As such, the clinical implication of this study is that there may be a possible protective mechanism by increasing the knee flexion angle during landing phase, which tends to protect the ACL from vigorous strain and injuries.

  12. The effects of a 3-month controlled hiking programme on the functional abilities of patients following total knee arthroplasty: a prospective, randomized trial.

    PubMed

    Hepperger, Caroline; Gföller, Peter; Hoser, Christian; Ulmer, Hanno; Fischer, Felix; Schobersberger, Wolfgang; Fink, Christian

    2017-11-01

    Improvements in pain, function and sports activity are the main goals of patients following total knee arthroplasty (TKA). Participation in sports has become an increasingly important contributor to patients' quality of life (QoL). Hiking is one of the most popular summer activities among elderly people in alpine regions. Consequently, this randomized controlled trial investigates the impact of a 3-month guided hiking programme on patients' functional abilities and QoL following TKA. It was hypothesized that patients who participate in this programme would demonstrate improvements in functional and QoL parameters compared with a control group. Forty-eight TKA patients were included and randomized into either the intervention group (IG; n = 25) or the control group (CG; n = 23). The IG participated in a 3-month hiking programme (2-3 times a week), whereas the CG performed activities of daily living. The stair climb test (SCT), QoL questionnaires and isokinetic force measurements were completed at three time points (i.e. pre-test, post-test, retention-test). ANOVAs for repeated measurements were conducted for the SCT results. The Friedman test and the Mann-Whitney U test were performed for the QoL parameters. After the 3-month hiking programme, the IG achieved faster overall walking times on the SCT. The time decreased from 4.3 ± 0.6 s (pre-test) to 3.6 ± 0.4 s (post-test) for the stair ascent (p = 0.060) and from 3.6 ± 0.6 s (pre-test) to 3.2 ± 0.5 s (post-test) for the stair descent (p = 0.036). The IG showed significant improvement on some of the subscales of the Knee Injury and Osteoarthritis Outcome Score from pre-test to retention-test (p < 0.01). In the CG, no significant changes were observed (n.s.). The results indicate moderate improvement in the functional abilities and QoL of TKA patients who participated in a 3-month guided hiking programme compared with the patients in the CG. Hiking did not have any acute detrimental effects on the TKA patients during this study period. II.

  13. Inter-Observer and Intra-Observer Reliability of Clinical Assessments in Knee Osteoarthritis

    PubMed Central

    Maricar, Nasimah; Callaghan, Michael J; Parkes, Matthew J; Felson, David T; O’Neill, Terence W

    2016-01-01

    Background Clinical examination of the knee is subject to measurement error. The aim of this analysis was to determine inter- and intra-observer reliability of commonly used clinical tests in patients with knee osteoarthritis(OA). Methods We studied subjects with symptomatic knee OA who were participants in an open-label clinical trial of intra-articular steroid therapy. Following standardisation of the clinical test procedures, two clinicians assessed 25 subjects independently at the same visit, and the same clinician assessed 88 subjects over an interval period of 2–10 weeks; in both cases prior to the steroid intervention. Clinical examination included assessment of bony enlargement, crepitus, quadriceps wasting, knee effusion, joint-line and anserine tenderness and knee range of movement(ROM). Intra-class correlation coefficients(ICC), estimated kappa(κ), weighted kappa(κω) and Bland and Altman plots were used to determine inter- and intra-observer levels of agreement. Results Using Landis and Koch criteria, inter-observer kappa scores were moderate for patellofemoral joint(κ=0.53) and anserine tenderness(κ=0.48); good for bony enlargement(κ=0.66), quadriceps wasting(κ=0.78), crepitus(κ=0.78), medial tibiofemoral joint tenderness(κ=0.76), and effusion assessed by ballottement(κ=0.73) and bulge sign(κω =0.78); and excellent for lateral tibiofemoral joint tenderness(κ=1.00), flexion(ICC=0.97) and extension(ICC=0.87) ROM. Intra-observer kappa scores were moderate for lateral tibiofemoral joint tenderness(κ=0.60), good for crepitus(κ=0.78), effusion assessed by ballottement test(κ=0.77), patellofemoral joint(κ=0.66), medial tibiofemoral joint(κ=0.64) and anserine(κ=0.73) tenderness and excellent for effusion assessed by bulge sign(κω =0.83), bony enlargement(κ=0.98), quadriceps wasting(κ=0.83), flexion(ICC=0.99) and extension(ICC=0.96) ROM. Conclusion Among individuals with symptomatic knee OA, the reliability of clinical examination of the knee was at least good for the majority of clinical signs of knee OA. PMID:27909143

  14. Associations of knee extensor strength and standing balance with physical function in knee osteoarthritis.

    PubMed

    Pua, Yong-Hao; Liang, Zhiqi; Ong, Peck-Hoon; Bryant, Adam L; Lo, Ngai-Nung; Clark, Ross A

    2011-12-01

    Knee extensor strength is an important correlate of physical function in patients with knee osteoarthritis; however, it remains unclear whether standing balance is also a correlate. The purpose of this study was to evaluate the cross-sectional associations of knee extensor strength, standing balance, and their interaction with physical function. One hundred four older adults with end-stage knee osteoarthritis awaiting a total knee replacement (mean ± SD age 67 ± 8 years) participated. Isometric knee extensor strength was measured using an isokinetic dynamometer. Standing balance performance was measured by the center of pressure displacement during quiet standing on a balance board. Physical function was measured by the self-report Short Form 36 (SF-36) questionnaire and by the 10-meter fast-pace gait speed test. After adjustment for demographic and knee pain variables, we detected significant knee strength by standing balance interaction terms for both SF-36 physical function and fast-pace gait speed. Interrogation of the interaction revealed that standing balance in the anteroposterior plane was positively related to physical function among patients with lower knee extensor strength. Conversely, among patients with higher knee extensor strength, the standing balance-physical function associations were, or tended to be, negative. These findings suggest that although standing balance was related to physical function in patients with knee osteoarthritis, this relationship was complex and dependent on knee extensor strength level. These results are of importance in developing intervention strategies and refining theoretical models, but they call for further study. Copyright © 2011 by the American College of Rheumatology.

  15. Effects of neuromuscular training (NEMEX-TJR) on patient-reported outcomes and physical function in severe primary hip or knee osteoarthritis: a controlled before-and-after study.

    PubMed

    Ageberg, Eva; Nilsdotter, Anna; Kosek, Eva; Roos, Ewa M

    2013-08-08

    The benefits of exercise in mild and moderate knee or hip osteoarthritis (OA) are apparent, but the evidence in severe OA is less clear. We recently reported that neuromuscular training was well tolerated and feasible in patients with severe primary hip or knee OA. The aims of this controlled before-and-after study were to compare baseline status to an age-matched population-based reference group and to examine the effects of neuromuscular training on patient-reported outcomes and physical function in patients with severe primary OA of the hip or knee. 87 patients (60-77 years) with severe primary OA of the hip (n = 38, 55% women) or knee (n = 49, 59% women) awaiting total joint replacement (TJR) had supervised, neuromuscular training (NEMEX-TJR) in groups with individualized level and progression of training. A reference group (n = 43, 53% women) was included for comparison with patients' data. Assessments included self-reported outcomes (HOOS/KOOS) and measures of physical function (chair stands, number of knee bends/30 sec, knee extensor strength, 20-meter walk test) at baseline and at follow-up before TJR. Analysis of covariance (ANCOVA) was used for comparing patients and references and elucidating influence of demographic factors on change. The paired t-test was used for comparisons within groups. At baseline, patients reported worse scores than the references in all HOOS/KOOS subscales (hip 27-47%, knee 14-52%, of reference scores, respectively) and had functional limitations (hip 72-85%, knee 42-85%, of references scores, respectively). NEMEX-TJR (mean 12 weeks (SD 5.6) of training) improved self-reported outcomes (hip 9-29%, knee 7-20%) and physical function (hip 3-18%, knee 5-19%) (p < 0.005). Between 42% and 62% of hip OA patients, and 39% and 61% of knee OA patients, displayed a clinically meaningful improvement (≥15%) in HOOS/KOOS subscales by training. The improvement in HOOS/KOOS subscale ADL was greater for patients with knee OA than hip OA, while the improvement in subscale Sport/Rec was greater for patients with hip OA than knee OA. Both self-reported outcomes and physical function were clearly worse compared with the reference group. Neuromuscular training with an individualized approach and gradual progression showed promise for improving patient-reported outcomes and physical function even in older patients with severe primary OA of the hip or knee.

  16. Core strength and lower extremity alignment during single leg squats.

    PubMed

    Willson, John D; Ireland, Mary Lloyd; Davis, Irene

    2006-05-01

    Muscles of the trunk, hip, and knee influence the orientation of the lower extremity during weight bearing activities. The purpose of this study was threefold: first, to compare the orientation of the lower extremity during a single leg (SL) squat among male and female athletes; second, to compare the strength of muscle groups in the trunk, hips, and knees between these individuals; and third, to evaluate the association between trunk, hip, and knee strength and the orientation of the knee joint during this activity. Twenty-four male and 22 female athletes participated in this study. Peak isometric torque was determined for the following muscle actions: trunk flexion, extension, and lateral flexion, hip abduction and external rotation, and knee flexion and extension. The frontal plane projection angle (FPPA) of the knee during a 45 degrees SL squat was determined using photo editing software. Males and females moved in opposite directions during the SL squat test (F(1,42) = 5.05, P = 0.03). Females typically moved toward more extreme FPPA during SL squats (P = 0.056), while males tended to move toward more neutral alignment (P = 0.066). Females also generated less torque in all muscle groups, with the exception of trunk extension. The projection angle of the knee during the SL squat test was most closely associated with hip external rotation strength. Using instruments suitable for a clinical setting, females were found to have greater FPPA and generally decreased trunk, hip, and knee isometric torque. Hip external rotation strength was most closely associated with the frontal plane projection angle.

  17. Individual MRI and radiographic features of knee OA in subjects with unilateral knee pain: Health ABC study

    PubMed Central

    Javaid, MK; Kiran, A; Guermazi, A; Kwoh, K; Zaim, S; Carbone, L; Harris, T.; McCulloch, C.E.; Arden, NK; Lane, NE; Felson, D; Nevitt, M

    2012-01-01

    Strong associations between radiographic features of knee OA and pain have been demonstrated in persons with unilateral knee symptoms. Our objectives were to compare radiographic with MRI features of knee OA and assess the discrimination between painful and non-painful knees in persons with unilateral symptoms. 283 individuals with unilateral knee pain aged 71 to 80 years from Health ABC, a study of weight-related diseases and mobility, had bilateral knee radiographs, read for KL grade and individual radiographic features, and 1.5T MRIs, read using WORMS. The association of structural features with pain was assessed using a within-person case/control design and conditional logistic regression. Receiver operator characteristics (ROC) were then used to test the discriminatory performance of structural features. In conditional logistic analyses, knee pain was significantly associated with both radiographic (any JSN grade >=1: OR 3.20 (1.79 – 5.71) and MRI (any cartilage defect:>=2: OR 3.67 (1.49 – 9.04)) features. However, most subjects had MR detected osteophytes, cartilage and bone marrow lesions in both knees and no individual structural feature discriminated well between painful and non-painful knees using ROC. The best performing MRI feature (synovitis/effusion) was not significantly more informative than KL grade >=2 (p=0.42). In persons with unilateral knee pain, MR and radiographic features were associated with knee pain confirming an important role in the etiology of pain. However, no single MRI or radiographic finding performed well in discriminating painful from non-painful knees. Further work is needed to examine how structural and non-structural factors influence knee pain. PMID:22736267

  18. Knee implant imaging at 3 Tesla using high-bandwidth radiofrequency pulses.

    PubMed

    Bachschmidt, Theresa J; Sutter, Reto; Jakob, Peter M; Pfirrmann, Christian W A; Nittka, Mathias

    2015-06-01

    To investigate the impact of high-bandwidth radiofrequency (RF) pulses used in turbo spin echo (TSE) sequences or combined with slice encoding for metal artifact correction (SEMAC) on artifact reduction at 3 Tesla in the knee in the presence of metal. Local transmit/receive coils feature increased maximum B1 amplitude, reduced SAR exposition and thus enable the application of high-bandwidth RF pulses. Susceptibility-induced through-plane distortion scales inversely with the RF bandwidth and the view angle, hence blurring, increases for higher RF bandwidths, when SEMAC is used. These effects were assessed for a phantom containing a total knee arthroplasty. TSE and SEMAC sequences with conventional and high RF bandwidths and different contrasts were tested on eight patients with different types of implants. To realize scan times of 7 to 9 min, SEMAC was always applied with eight slice-encoding steps and distortion was rated by two radiologists. A local transmit/receive knee coil enables the use of an RF bandwidth of 4 kHz compared with 850 Hz in conventional sequences. Phantom scans confirm the relation of RF bandwidth and through-plane distortion, which can be reduced up to 79%, and demonstrate the increased blurring for high-bandwidth RF pulses. In average, artifacts in this RF mode are rated hardly visible for patients with joint arthroplasties, when eight SEMAC slice-encoding steps are applied, and for patients with titanium fixtures, when TSE is used. The application of high-bandwidth RF pulses by local transmit coils substantially reduces through-plane distortion artifacts at 3 Tesla. © 2014 Wiley Periodicals, Inc.

  19. Improved knee biomechanics among patients reporting a good outcome in knee-related quality of life one year after total knee arthroplasty.

    PubMed

    Naili, Josefine E; Wretenberg, Per; Lindgren, Viktor; Iversen, Maura D; Hedström, Margareta; Broström, Eva W

    2017-03-21

    It is not well understood why one in five patients report poor outcomes following knee arthroplasty. This study evaluated changes in knee biomechanics, and perceived pain among patients reporting either a good or a poor outcome in knee-related quality of life after total knee arthroplasty. Twenty-eight patients (mean age 66 (SD 7) years) were included in this prospective study. Within one month of knee arthroplasty and one year after surgery, patients underwent three-dimensional (3D) gait analysis, completed the Knee Injury and Osteoarthritis Outcome Score (KOOS), and rated perceived pain using a visual analogue scale. A "good outcome" was defined as a change greater than the minimally detectable change in the KOOS knee-related quality of life, and a "poor outcome" was defined as change below the minimally detectable change. Nineteen patients (68%) were classified as having a good outcome. Groups were analyzed separately and knee biomechanics were compared using a two-way repeated measures ANOVA. Differences in pain between groups were evaluated using Mann Whitney U test. Patients classified as having a good outcome improved significantly in most knee gait biomechanical outcomes including increased knee flexion-extension range, reduced peak varus angle, increased peak flexion moment, and reduced peak valgus moment. The good outcome group also displayed a significant increase in walking speed, a reduction (normalization) of stance phase duration (% of gait cycle) and increased passive knee extension. Whereas, the only change in knee biomechanics, one year after surgery, for patients classified as having a poor outcome was a significant reduction in peak varus angle. No differences in pain postoperatively were found between groups. Patients reporting a good outcome in knee-related quality of life improved in knee biomechanics during gait, while patients reporting a poor outcome, despite similar reduction in pain, remained unchanged in knee biomechanics one year after total knee arthroplasty. With regards to surgeon-controlled biomechanical factors, surgery may most successfully address frontal plane knee alignment. However, achieving a good outcome in patient-reported knee-related quality of life may be related to dynamic improvements in the sagittal plane.

  20. [Evaluation of the clinical results in patients with symptomatic partial tears of the anterior cruciate ligament diagnosed arthroscopically].

    PubMed

    Zeman, P; Cibulková, J; Nepraš, P; Koudela, K; Matějka, J

    2013-01-01

    The study presents a retrospective evaluation of clinical data and arthroscopic findings in a group of our patients with symptomatic knee instability due to a partial tear of the anterior cruciate ligament (ACL). The group included 31 patients diagnosed with symptomatic partial ACL tears, i.e. an isolated tear of the posterolateral (PL) or the anteromedial (AM) bundle. The patients' average age was 26.5 years. A side-to-side difference in ventral knee laxity was assessed using the anterior drawer test and the Lachman test under general anaesthesia before arthroscopy was commenced; rotational knee laxity was evaluated by the pivot shift test. An objective evaluation of side-to-side ventral laxity differences in both knees was performed on the GNRB® arthrometer with an applied pressure of 134 N and 250 N in the conscious patient. During arthroscopic examination, findings on the two ACL bundles were recorded. All 31 patients were diagnosed with symptomatic partial ACL tears, of them 22 had a PL bundle lesion and nine had an AM bundle tear. All patients with PL bundle lesions only reported problems in association with pivot sports, and all patients with AM bundle tears had problems regardless of any sports activities. In all patients with isolated AM bundle tears, the lesion was located close to its femoral attachment. In the patients with PL bundle tears, femoral location was found in 68% and tibial location in 32% of the patients. In the patients with partial PL bundle lesions, + and ++ results in the pivot shift test were recorded in 32% and 68% of the treated patients, respectively. The Lachman test showed + and ++ results in 71% and 9% of the patients, respectively. The anterior drawer test had negative results in 87% and positive + results in 13% of the patients. The side-to-side difference on the GNRB arthrometer ranged from 0.4 to 2.3 mm at a pressure of 134 N and from 1.2 to 4.2 mm at 250 N in the patients with isolated PL bundle lesions. In the patients with AM bundle lesions, the results were as follows: pivot shift test, 89% negative. 11% positive +; Lachman test, 56% negative, 44% positive +; anterior drawer test, 89% +, 11% ++; GNRB test, 2.2 to 4.4 mm at 134 N, and 4.3 to 7.1 at 250 N. The diagnosis of partial ACL lesions, i.e., isolated tears of the AM or the PL bundle, requires accurate knowledge of knee anatomy and its biomechanics. In accordance with other authors our results showed that an arthroscopic examination of both bundles of the ligament as well as knee laxity evaluation under general anaesthesia are most essential for making the definite diagnosis in partial ACL tears. They also confirmed that, in isolated AM bundle lesions, ventral laxity is present more often particularly at a higher degree of knee flexion while, in PL bundle lesions, rotational laxity is more frequent and ranges from 0 to 30 degrees of knee flexion. To make the definite diagnosis of partial ACL tears, patient medical history, clinical knee examination including instability type and degree assessment under general anaesthesia and, most importantly, arthroscopic findings on both ACL bundles are necessary.

  1. Study of the relation between body weight and functional limitations and pain in patients with knee osteoarthritis.

    PubMed

    Alfieri, Fábio Marcon; Silva, Natália Cristina de Oliveira Vargas E; Battistella, Linamara Rizzo

    2017-01-01

    To assess the influence of the body weight in functional capacity and pain of adult and elderly individuals with knee osteoarthritis. The sample consisted of 107 adult and elderly patients with knee osteoarthritis divided into two groups (adequate weight/adiposity and excessive weight/adiposity) according to body mass index and percent of body fat mass, assessed by electric bioimpedance. Subjects were evaluated for functional mobility (Timed Up and Go Test), pain, stiffness and function (Western Ontario and MacMaster Universities Osteoarthritis Index - WOMAC), pain intensity (Visual Analogue Scale - VAS) and pressure pain tolerance threshold (algometry in vastus medialis and vastus lateralis muscles). Data were analyzed with Statistical Package of the Social Sciences, version 22 for Windows. Comparisons between groups were made through Student's t test, with significance level set at 5%. There was predominance of females in the sample (81.3%), and mean age was 61.8±10.1 years. When dividing the sample by both body mass index and adiposity, 89.7% of them had weight/adiposity excess, and 59.8% were obese. There was no difference between groups regarding age, pain intensity, pressure pain tolerance threshold, functional mobility, stiffness and function. However, pain (WOMAC) was higher (p=0.05) in the group of patients with weight or adiposity excess, and pain perception according to VAS was worse in the group of obese patients (p=0.05). Excessive weight had negative impact in patients with osteoarthritis, increasing pain assessed by WOMAC or VAS, although no differences were observed in functionality and pressure pain tolerance.

  2. Correlation between hip function and knee kinematics evaluated by three-dimensional motion analysis during lateral and medial side-hopping.

    PubMed

    Itoh, Hiromitsu; Takiguchi, Kohei; Shibata, Yohei; Okubo, Satoshi; Yoshiya, Shinichi; Kuroda, Ryosuke

    2016-09-01

    [Purpose] Kinematic and kinetic characteristics of the limb during side-hopping and hip/knee interaction during this motion have not been clarified. The purposes of this study were to examine the biomechanical parameters of the knee during side hop and analyze its relationship with clinical measurements of hip function. [Subjects and Methods] Eleven male college rugby players were included. A three-dimensional motion analysis system was used to assess motion characteristics of the knee during side hop. In addition, hip range of motion and muscle strength were evaluated. Subsequently, the relationship between knee motion and the clinical parameters of the hip was analyzed. [Results] In the lateral touchdown phase, the knee was positioned in an abducted and externally rotated position, and increasing abduction moment was applied to the knee. An analysis of the interaction between knee motion and hip function showed that range of motion for hip internal rotation was significantly correlated with external rotation angle and external rotation/abduction moments of the knee during the lateral touchdown phase. [Conclusion] Range of motion for hip internal rotation should be taken into consideration for identifying the biomechanical characteristics in the side hop test results.

  3. Correlation between hip function and knee kinematics evaluated by three-dimensional motion analysis during lateral and medial side-hopping

    PubMed Central

    Itoh, Hiromitsu; Takiguchi, Kohei; Shibata, Yohei; Okubo, Satoshi; Yoshiya, Shinichi; Kuroda, Ryosuke

    2016-01-01

    [Purpose] Kinematic and kinetic characteristics of the limb during side-hopping and hip/knee interaction during this motion have not been clarified. The purposes of this study were to examine the biomechanical parameters of the knee during side hop and analyze its relationship with clinical measurements of hip function. [Subjects and Methods] Eleven male college rugby players were included. A three-dimensional motion analysis system was used to assess motion characteristics of the knee during side hop. In addition, hip range of motion and muscle strength were evaluated. Subsequently, the relationship between knee motion and the clinical parameters of the hip was analyzed. [Results] In the lateral touchdown phase, the knee was positioned in an abducted and externally rotated position, and increasing abduction moment was applied to the knee. An analysis of the interaction between knee motion and hip function showed that range of motion for hip internal rotation was significantly correlated with external rotation angle and external rotation/abduction moments of the knee during the lateral touchdown phase. [Conclusion] Range of motion for hip internal rotation should be taken into consideration for identifying the biomechanical characteristics in the side hop test results. PMID:27799670

  4. Biomechanical Evaluation of Knee Joint Laxities and Graft Forces After Anterior Cruciate Ligament Reconstruction by Anteromedial Portal, Outside-In, and Transtibial Techniques

    PubMed Central

    Sim, Jae Ang; Gadikota, Hemanth R.; Li, Jing-Sheng; Li, Guoan; Gill, Thomas J.

    2013-01-01

    Background Recently, anatomic anterior cruciate ligament (ACL) reconstruction is emphasized to improve joint laxity and to potentially avert initiation of cartilage degeneration. There is a paucity of information on the efficacy of ACL reconstructions by currently practiced tunnel creation techniques in restoring normal joint laxity. Study Design Controlled laboratory study. Hypothesis Anterior cruciate ligament reconstruction by the anteromedial (AM) portal technique, outside-in (OI) technique, and modified transtibial (TT) technique can equally restore the normal knee joint laxity and ACL forces. Methods Eight fresh-frozen human cadaveric knee specimens were tested using a robotic testing system under an anterior tibial load (134 N) at 0°, 30°, 60°, and 90° of flexion and combined torques (10-N·m valgus and 5-N·m internal tibial torques) at 0° and 30° of flexion. Knee joint kinematics, ACL, and ACL graft forces were measured in each knee specimen under 5 different conditions (ACL-intact knee, ACL-deficient knee, ACL-reconstructed knee by AM portal technique, ACL-reconstructed knee by OI technique, and ACL-reconstructed knee by TT technique). Results Under anterior tibial load, no significant difference was observed between the 3 reconstructions in terms of restoring anterior tibial translation (P > .05). However, none of the 3 ACL reconstruction techniques could completely restore the normal anterior tibial translations (P <.05). Under combined tibial torques, both AM portal and OI techniques closely restored the normal knee anterior tibial translation (P > .05) at 0° of flexion but could not do so at 30° of flexion (P <.05). The ACL reconstruction by the TT technique was unable to restore normal anterior tibial translations at both 0° and 30° of flexion under combined tibial torques (P <.05). Forces experienced by the ACL grafts in the 3 reconstruction techniques were lower than those experienced by normal ACL under both the loading conditions. Conclusion Anterior cruciate ligament reconstructions by AM portal, OI, and modified TT techniques are biomechanically comparable with each other in restoring normal knee joint laxity and in situ ACL forces. Clinical Relevance Anterior cruciate ligament reconstructions by AM portal, OI, and modified TT techniques result in similar knee joint laxities. Technical perils and pearls should be carefully considered before choosing a tunnel creating technique. PMID:21908717

  5. [EFFECTIVENESS OF ONE-STAGE REPAIR AND RECONSTRUCTION FOR KNEE DISLOCATION WITH MULTIPLE LIGAMENT INJURIES].

    PubMed

    Sun, Zhengyu; Zhang, Chenghao; Tang, Xin; Chen, Gang; Li, Jian

    2016-06-08

    To evaluate the surgical procedure and short-term effectiveness of one-stage repair and reconstruction of knee dislocation with multiple ligament injuries (KDMLI). Between September 2010 and April 2014, 9 cases (9 knees) of KDMLI were treated. There were 7 males and 2 females with an average age of 42 years (range, 27-57 years). Injury was caused by traffic accident in 3 cases, heavy-weight crushing in 3 cases, sports sprain in 2 cases, and falling from height in 1 case. The average time from injury to operation was 11 days (range, 3-19 days). The results of posterior drawer test and Lachman test were positive in all patients. The results of varus stress testing were three-degree positive in 4 cases, and the results of valgus stress testing were three-degree positive in 6 cases. The Lysholm score of knee was 27.2±6.3; the International Knee Documentation Committee (IKDC) score was 29.7±6.5; and the range of motion (ROM) was (52.6±12.8)°. All patients suffered from posterior cruciate ligament (PCL) injury and femoral avulsion injury of anterior cruciate ligament (ACL). Combined injuries included medial collateral ligament (MCL) injury in 4 cases (medial meniscus injury in 1 case), lateral collateral ligament (LCL) injury in 2 cases, and MCL and LCL injuries in 2 cases (medial meniscus and lateral meniscus injuries in 1 case). Autologous harmstring tendon was used to reconstruct PCL under arthroscopy combined with limited open in situ suture for repair of femoral avulsion injury of ACL, and repair of MCL, LCL, and other injury in one-stage operation. All incisions healed by first intention. Joint effusion of knee occurred in 1 case and was cured after removal of fluid combined with pressure bandage. All patients were followed up 12-36 months with an average of 22 months. At last follow-up, the result of posterior drawer test was negative in all patients. The results of Lachman test were one-degree positive in 2 cases; the result of varus stress testing was one-degree positive in 1 case; the results of valgus stress testing were one-degree positive in 2?cases; and flexion dysfunction of the knee was observed in 1 case. The Lysholm score of knee was 87.3±6.6; the IKDC score was 88.9±6.8; and the ROM was (121.7±12.3)°, all showing significant differences when compared with preoperative ones ( t =44.246, P =0.000; t =37.903, P =0.000; t =19.894, P =0.000). For KDMLI, one-stage repair and reconstruction using autologous harmstring tendon to reconst ruct PCL under arthroscopy combined with limited open in situ suture repair of femoral avulsion injury of ACL, and repair MCL, LCL, and other injury has such advantages as minimal invasiveness, reliable fixation, less complications, and fast recovery, which can significantly improve the stability, ROM, and function of knee and obtain good short-term effectiveness.

  6. The Effects of Knee Joint Effusion on Quadriceps Electromyography During Jogging

    PubMed Central

    Torry, Michael R.; Decker, Michael J.; Millett, Peter J.; Steadman, J. Richard; Sterett, William I.

    2005-01-01

    To investigate and describe the influence of intra-articular effusion on knee joint kinematics and electromyographic (EMG) profiles during jogging. Thirteen individuals underwent a 20 cc 0.9% saline insufflation of the knee joint capsule and completed 8 jogging trials. Stance phase, sagittal plane knee joint kinematics and thigh muscular EMG profiles were compared pre- and post-insufflation utilizing a paired t-test ( = 0.05). Mild knee effusion caused a reduction in vastus medialis (p = 0.005) and lateralis (p = 0.006) EMG activity. The rectus femoris, biceps femoris and medial hamstring muscles did not exhibit changes due to this protocol. There were no changes in the sagittal plane knee joint kinematic pattern. Twenty cc effusion can cause quadriceps inhibition in the vastus medialis and the vastus lateralis in otherwise healthy individuals during jogging. This study provides baseline data for the effects of mild knee joint effusion on thigh musculature during jogging. Key Points 20 cc of knee effusion can cause vastus medialis and lateralis inhibition as noted by decreases in EMG amplitude. This effusion does not appear to alter sagittal plane knee joint kinematics during jogging. This finding if different from previous work investigating knee joint kinematic changes during a less dynamic activity (gait) with 20 cc of effusion. PMID:24431955

  7. Sports activity following total knee arthroplasty in patients older than 60 years.

    PubMed

    Mayr, Hermann O; Reinhold, Maik; Bernstein, Anke; Suedkamp, Norbert P; Stoehr, Amelie

    2015-01-01

    In a retrospective study with a population over 65 years, sports activity was conducted 6 years after cruciate retaining (CR) total condylar knee arthroplasty (TKA) with rotating platform (RP). Eighty-one Patients (71.8±5.4years) were examined at follow-up 6.4±0.9 years postoperative. Sport was practiced 5.3 hours every week in mean. Patients were active in sports 3.5times per week. Twenty-five percent performed high impact sports, 47% medium impact sports and 52% low impact sports at follow-up. In KOOS sports 60±28 was reached, in WOMAC 12.1±15.1. It can be concluded that in this population 50% of patients were active in medium and low impact sport 6 years after surgery. However, a quarter of patients were also active in high impact sports. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. New Generation Lockable Knee Brace

    NASA Technical Reports Server (NTRS)

    2000-01-01

    A knee brace that uses Space Shuttle propulsion technology has moved a step closer to being available to help knee injury and stroke patients and may possibly benefit patients with birth defects, spinal cord injuries, and post-polio conditions. After years of hard work, inventors at NASA's Marshall Space Flight Center (MSFC) in Huntsville, Alabama, have turned over the final design and prototype to industry partners at Horton's Orthotic Lab in Little Rock, Arkansas for further clinical testing. The device, called the Selectively Lockable Knee Brace, may mean faster, less painful rehabilitation for patients by allowing the knee to move when weight is not on the heel. Devices currently on the market lock the knee in a rigid, straight-leg position, or allow continuous free motion. The knee brace is just one example of how space technology is being used to improve the lives of people on Earth. NASA's MSFC inventors Michael Shadoan and Neill Myers are space propulsion engineers who use the same mechanisms and materials to build systems for rockets that they used to design and develop the knee brace.

  9. Anterolateral Knee Extra-articular Stabilizers: A Robotic Sectioning Study of the Anterolateral Ligament and Distal Iliotibial Band Kaplan Fibers.

    PubMed

    Geeslin, Andrew G; Chahla, Jorge; Moatshe, Gilbert; Muckenhirn, Kyle J; Kruckeberg, Bradley M; Brady, Alex W; Coggins, Ashley; Dornan, Grant J; Getgood, Alan M; Godin, Jonathan A; LaPrade, Robert F

    2018-05-01

    The individual kinematic roles of the anterolateral ligament (ALL) and the distal iliotibial band Kaplan fibers in the setting of anterior cruciate ligament (ACL) deficiency require further clarification. This will improve understanding of their potential contribution to residual anterolateral rotational laxity after ACL reconstruction and may influence selection of an anterolateral extra-articular reconstruction technique, which is currently a matter of debate. Hypothesis/Purpose: To compare the role of the ALL and the Kaplan fibers in stabilizing the knee against tibial internal rotation, anterior tibial translation, and the pivot shift in ACL-deficient knees. We hypothesized that the Kaplan fibers would provide greater tibial internal rotation restraint than the ALL in ACL-deficient knees and that both structures would provide restraint against internal rotation during a simulated pivot-shift test. Controlled laboratory study. Ten paired fresh-frozen cadaveric knees (n = 20) were used to investigate the effect of sectioning the ALL and the Kaplan fibers in ACL-deficient knees with a 6 degrees of freedom robotic testing system. After ACL sectioning, sectioning was randomly performed for the ALL and the Kaplan fibers. An established robotic testing protocol was utilized to assess knee kinematics when the specimens were subjected to a 5-N·m internal rotation torque (0°-90° at 15° increments), a simulated pivot shift with 10-N·m valgus and 5-N·m internal rotation torque (15° and 30°), and an 88-N anterior tibial load (30° and 90°). Sectioning of the ACL led to significantly increased tibial internal rotation (from 0° to 90°) and anterior tibial translation (30° and 90°) as compared with the intact state. Significantly increased internal rotation occurred with further sectioning of the ALL (15°-90°) and Kaplan fibers (15°, 60°-90°). At higher flexion angles (60°-90°), sectioning the Kaplan fibers led to significantly greater internal rotation when compared with ALL sectioning. On simulated pivot-shift testing, ALL sectioning led to significantly increased internal rotation and anterior translation at 15° and 30°; sectioning of the Kaplan fibers led to significantly increased tibial internal rotation at 15° and 30° and anterior translation at 15°. No significant difference was found when anterior tibial translation was compared between the ACL/ALL- and ACL/Kaplan fiber-deficient states on simulated pivot-shift testing or isolated anterior tibial load. The ALL and Kaplan fibers restrain internal rotation in the ACL-deficient knee. Sectioning the Kaplan fibers led to greater tibial internal rotation at higher flexion angles (60°-90°) as compared with ALL sectioning. Additionally, the ALL and Kaplan fibers contribute to restraint of the pivot shift and anterior tibial translation in the ACL-deficient knee. This study reports that the ALL and distal iliotibial band Kaplan fibers restrain anterior tibial translation, internal rotation, and pivot shift in the ACL-deficient knee. Furthermore, sectioning the Kaplan fibers led to significantly greater tibial internal rotation when compared with ALL sectioning at high flexion angles. These results demonstrate increased rotational knee laxity with combined ACL and anterolateral extra-articular knee injuries and may allow surgeons to optimize the care of patients with this injury pattern.

  10. What Is the Proportion of Studies Reporting Patient and Practitioner Satisfaction with Software Support Tools Used in the Management of Knee Pain and Is This Related to Sample Size, Effect Size, and Journal Impact Factor?

    PubMed

    Bright, Philip; Hambly, Karen

    2017-12-21

    E-health software tools have been deployed in managing knee conditions. Reporting of patient and practitioner satisfaction in studies regarding e-health usage is not widely explored. The objective of this review was to identify studies describing patient and practitioner satisfaction with software use concerning knee pain. A computerized search was undertaken: four electronic databases were searched from January 2007 until January 2017. Key words were decision dashboard, clinical decision, Web-based resource, evidence support, and knee. Full texts were scanned for effect of size reporting and satisfaction scales from participants and practitioners. Binary regression was run; impact factor and sample size were predictors with indicators for satisfaction and effect size reporting as dependent variables. Seventy-seven articles were retrieved; 37 studies were included in final analysis. Ten studies reported patient satisfaction ratings (27.8%): a single study reported both patient and practitioner satisfaction (2.8%). Randomized control trials were the most common design (35%) and knee osteoarthritis the most prevalent condition (38%). Electronic patient-reported outcome measures and Web-based training were the most common interventions. No significant dependency was found within the regression models (p > 0.05). The proportion of reporting of patient satisfaction was low; practitioner satisfaction was poorly represented. There may be implications for the suitability of administering e-health, a medium for capturing further meta-evidence needs to be established and used as best practice for implicated studies in future. This is the first review of its kind to address patient and practitioner satisfaction with knee e-health.

  11. The Incidence and Short Term Functional Effect of Partial PCL Release in Fixed and Mobile Bearing PCL Retaining TKA.

    PubMed

    Schwarzkopf, Ran; Woolwine, Spencer; Josephs, Lee; Scott, Richard D

    2015-12-01

    Posterior cruciate ligament (PCL) release may be required to balance the flexion gap in PCL retaining TKA. This study examines the incidence and functional consequences of PCL release in both fixed and mobile bearing TKA. A consecutive series of 1388 TKAs with 1014 fixed bearing, and 374 mobile bearing implants were reviewed for prevalence of partial PCL release, restoration of potential flexion and objective knee stability at minimum one-year follow-up. Patients receiving mobile bearing inserts were more likely to need partial PCL release (42% versus 17.5%). The occurrence of partial PCL release did not have a significant impact on knee range of motion and subjective knee stability. The need for a partial PCL release appears to be greater in mobile than in fixed bearing. Knees that required a release in both groups demonstrated no difference in restoration of flexion compared with unreleased knees and no adverse effects on flexion stability. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. The effect of a dynamic PCL brace on patellofemoral compartment pressures in PCL-and PCL/PLC-deficient knees.

    PubMed

    Welch, Tyler; Keller, Thomas; Maldonado, Ruben; Metzger, Melodie; Mohr, Karen; Kvitne, Ronald

    2017-12-01

    The natural history of posterior cruciate ligament (PCL) deficiency includes the development of arthrosis in the patellofemoral joint (PFJ). The purpose of this biomechanical study was to evaluate the hypothesis that dynamic bracing reduces PFJ pressures in PCL- and combined PCL/posterolateral corner (PLC)-deficient knees. Controlled Laboratory Study. Eight fresh frozen cadaveric knees with intact cruciate and collateral ligaments were included. PFJ pressures and force were measured using a pressure mapping system via a lateral arthrotomy at knee flexion angles of 30°, 60°, 90°, and 120° in intact, PCL-deficient, and PCL/PLC-deficient knees under a combined quadriceps/hamstrings load of 400 N/200 N. Testing was then repeated in PCL- and PCL/PLC-deficient knees after application of a dynamic PCL brace. Application of a dynamic PCL brace led to a reduction in peak PFJ pressures in PCL-deficient knees. In addition, the brace led to a significant reduction in peak pressures in PCL/PLC-deficient knees at 60°, 90°, and 120° of flexion. Application of the dynamic brace also led to a reduction in total PFJ force across all flexion angles for both PCL- and PCL/PLC-deficient knees. Dynamic bracing reduces PFJ pressures in PCL- and combined PCL/PLC-deficient knees, particularly at high degrees of knee flexion.

  13. Cross-cultural Adaptation and Validation of the Simplified Chinese Version of the Knee Outcome Survey Activities of Daily Living Scale.

    PubMed

    Jia, Zhen-Yu; Wang, Wei; Nian, Xin-Wen; Zhang, Xiao-Xi; Huang, Zhi-Ping; Cui, Jin; Xu, Wei-Dong

    2016-10-01

    To perform a cross-cultural adaptation and translation of the original version of the Activities of Daily Living Scale of the Knee Outcome Survey into Simplified Chinese and validate of the Simplified Chinese version. The original version was translated and cross-culturally adapted into Simplified Chinese according to the guidelines and the recommendations of the American Academy of Orthopaedic Surgeons Outcome Committee. A total of 213 patients (96 male, 117 female) were selected to participate in our investigation. The inclusion criteria were as follows: 18 years of age and older, able to speak Chinese Mandarin and read Simplified Chinese, and referred to physical therapy for evaluation and treatment for a knee disorder. The exclusion criteria were as follows: patients who had disorders or impairments involving both knees, patients who had other conditions that could affect lower extremity function, patients with physical therapy related to the knee in the previous 1 month, and patients with psychological problems. Each participant was asked to complete the Knee Outcome Survey Activities of Daily Living Scale (KOS-ADLS), International Knee Documentation Committee Subjective Knee Form, Western Ontario and McMaster Universities Osteoarthritis Index, and Short Form 36 forms and to provide baseline demographic data. Each participant completed the KOS-ADLS twice on 2 nonconsecutive days for reliability evaluation. A portion of the participants (n = 161) finished the KOS-ADLS a third time 4 weeks after physical treatment to test responsiveness. The original version of the KOS-ADLS was well adapted and translated into Simplified Chinese. Simplified Chinese of KOS-ADLS was shown to have good internal consistency (Cronbach's alpha = 0.855 to 0.929), great test-retest reliability (intraclass correlation coefficient = 0.935 to 0.961), high construct validity as we hypothesized (significant correlations with Short Form 36 subscales, Western Ontario and McMaster Universities Osteoarthritis Index, and International Knee Documentation Committee Subjective Knee Form), and high responsiveness (standard response means = 0.97 to 1.23, standard effect size = 0.81 to 0.91). Simplified Chinese of KOS-ADLS was shown to have good reliability, validity, and responsiveness for use in patients with knee disorders in China. Level II, testing of previously developed diagnostic criteria in a series of consecutive patients with universally applied gold standard. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  14. Leg stiffness, valgus knee motion, and Q-angle are associated with hypertrophic soft patella tendon and idiopathic knee pain in adolescent basketball players.

    PubMed

    Satkunskiene, Danguole; Mickevicius, Mantas; Snieckus, Audrius; Kamandulis, Sigitas

    2017-01-01

    Knee pain without knee degenerative symptoms is a common phenomenon among young basketball players. The aim of this study was to identify factors predisposing young basketball players to suffer from knee pain. The study involved 20 male adolescent (14-15 years) basketball players who were divided into two equal groups based on knee pain symptoms. Legs torque was tested on an isokinetic dynamometer. The length, elongation and the cross-sectional area (CSA) of the patellar tendon were measured with ultrasonography. Quadriceps angle (Q-angle), knee valgus motion, and joint angular displacement in the sagittal plane were analyzed using video recording during countermovement jump. Ground reaction force was measured using a force platform. Knee pain (KP) participants had a significantly lower Q-angle (P=0.045) and lower maximum varus knee angle (P=0.035), and a greater knee inside displacement (P=0.039) during squat phase. In the KP group, the CSA at the top of the tendon was significantly greater than in the middle (P=0.006) and at the bottom (P=0.039). Absolute tendon stiffness (P=0.013) and Young's modulus (P=0.034) were significantly lower in the KP group compared with controls. Leg stiffness during landing was significantly greater in the control group (P=0.015). Leg stiffness, valgus knee motion, and Q-angle are associated with hypertrophic soft patella tendon and idiopathic knee pain in adolescent basketball players.

  15. Effect of knee angle on neuromuscular assessment of plantar flexor muscles: A reliability study

    PubMed Central

    Cornu, Christophe; Jubeau, Marc

    2018-01-01

    Introduction This study aimed to determine the intra- and inter-session reliability of neuromuscular assessment of plantar flexor (PF) muscles at three knee angles. Methods Twelve young adults were tested for three knee angles (90°, 30° and 0°) and at three time points separated by 1 hour (intra-session) and 7 days (inter-session). Electrical (H reflex, M wave) and mechanical (evoked and maximal voluntary torque, activation level) parameters were measured on the PF muscles. Intraclass correlation coefficients (ICC) and coefficients of variation were calculated to determine intra- and inter-session reliability. Results The mechanical measurements presented excellent (ICC>0.75) intra- and inter-session reliabilities regardless of the knee angle considered. The reliability of electrical measurements was better for the 90° knee angle compared to the 0° and 30° angles. Conclusions Changes in the knee angle may influence the reliability of neuromuscular assessments, which indicates the importance of considering the knee angle to collect consistent outcomes on the PF muscles. PMID:29596480

  16. Study of Wearable Knee Assistive Instruments for Walk Rehabilitation

    NASA Astrophysics Data System (ADS)

    Zhu, Yong; Nakamura, Masahiro; Ito, Noritaka; Fujimoto, Hiroshi; Horikuchi, Kenichi; Wakabayashi, Shojiro; Takahashi, Rei; Terada, Hidetsugu; Haro, Hirotaka

    A wearable Knee Assistive Instrument for the walk rehabilitation was newly developed. Especially, this system aimed at supporting the rehabilitation for the post-TKA (Total Knee Arthroplasty) which is a popular surgery for aging people. This system consisted of an assisting mechanism for the knee joint, a hip joint support system and a foot pressure sensor system. The driving system of this robot consisted of a CPU board which generated the walking pattern, a Li-ion battery, DC motors with motor drivers, contact sensors to detect the state of foot and potentiometers to detect the hip joint angle. The control method was proposed to reproduce complex motion of knee joint as much as possible, and to increase hip or knee flexion angle. Especially, this method used the timing that heel left from the floor. This method included that the lower limb was raised to prevent a subject's fall. Also, the prototype of knee assisting system was tested. It was confirmed that the assisting system is useful.

  17. Maximum step length: relationships to age and knee and hip extensor capacities.

    PubMed

    Schulz, Brian W; Ashton-Miller, James A; Alexander, Neil B

    2007-07-01

    Maximum Step Length may be used to identify older adults at increased risk for falls. Since leg muscle weakness is a risk factor for falls, we tested the hypotheses that maximum knee and hip extension speed, strength, and power capacities would significantly correlate with Maximum Step Length and also that the "step out and back" Maximum Step Length [Medell, J.L., Alexander, N.B., 2000. A clinical measure of maximal and rapid stepping in older women. J. Gerontol. A Biol. Sci. Med. Sci. 55, M429-M433.] would also correlate with the Maximum Step Length of its two sub-tasks: stepping "out only" and stepping "back only". These sub-tasks will be referred to as versions of Maximum Step Length. Unimpaired younger (N=11, age=24[3]years) and older (N=10, age=73[5]years) women performed the above three versions of Maximum Step Length. Knee and hip extension speed, strength, and power capacities were determined on a separate day and regressed on Maximum Step Length and age group. Version and practice effects were quantified and subjective impressions of test difficulty recorded. Hypotheses were tested using linear regressions, analysis of variance, and Fisher's exact test. Maximum Step Length explained 6-22% additional variance in knee and hip extension speed, strength, and power capacities after controlling for age group. Within- and between-block and test-retest correlation values were high (>0.9) for all test versions. Shorter Maximum Step Lengths are associated with reduced knee and hip extension speed, strength, and power capacities after controlling for age. A single out-and-back step of maximal length is a feasible, rapid screening measure that may provide insight into underlying functional impairment, regardless of age.

  18. Cellular Telephone Dialing Influences Kinematic and Spatiotemporal Gait Parameters in Healthy Adults.

    PubMed

    Seymour, Kelly M; Higginson, Christopher I; DeGoede, Kurt M; Bifano, Morgan K; Orr, Rachel; Higginson, Jill S

    2016-01-01

    Gait speed is typically reduced when individuals simultaneously perform other tasks. However, the impact of dual tasking on kinetic and kinematic gait parameters is unclear because these vary with gait speed. The objective of this study was to identify whether dual tasking impacts gait in healthy adults when speed is constant. Twenty-two healthy adults dialed a cell phone during treadmill walking at a self-selected speed while kinetic, kinematic, and spatial parameters were recorded. Results indicated that dual tasking did not impact phone dialing speed, but increased stride width, peak knee flexion during stance, and peak plantarflexion, and decreased knee and ankle range of motion. Dual tasking appears to influence kinematic gait variables in a manner consistent with promotion of stability.

  19. A rolling-gliding wear simulator for the investigation of tribological material pairings for application in total knee arthroplasty.

    PubMed

    Richter, Berna I; Ostermeier, Sven; Turger, Anke; Denkena, Berend; Hurschler, Christof

    2010-06-15

    Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only. A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made. The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures. The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in knee joint replacement implants.

  20. A rolling-gliding wear simulator for the investigation of tribological material pairings for application in total knee arthroplasty

    PubMed Central

    2010-01-01

    Background Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only. Methods A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made. Results The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures. Conclusions The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in knee joint replacement implants. PMID:20550669

  1. Medial Patellofemoral Ligament Reconstruction: Impact of Knee Flexion Angle During Graft Fixation on Dynamic Patellofemoral Contact Pressure-A Biomechanical Study.

    PubMed

    Lorbach, Olaf; Zumbansen, Nikolaus; Kieb, Matthias; Efe, Turgay; Pizanis, Antonius; Kohn, Dieter; Haupert, Alexander

    2018-04-01

    Objective evaluation of the optimal graft tension angle to fully restore patellofemoral contact pressure in reconstruction of the medial patellofemoral ligament (MPFL) in comparison to the native knee. Twelve cadaveric knee specimens were fixed in a custom-made fixation device. A sensitive pressure film (Tekscan) was fixed in the patellofemoral joint, and patellofemoral contact pressure was assessed during a dynamic flexion movement from 0° to 90°. The MPFL was cut and measurements were repeated. Reconstruction of the MPFL was performed with the gracilis tendon subsequently fixed in the femur at 15°, 30°, 45°, 60°, 75°, and 90° of knee flexion under controlled tension (2 N). The sequence of the flexion angles was alternated. Pressure measurements were repeated after every fixation of the graft. No significant differences were seen in the overall patellofemoral contact pressure compared to the native knee (P > .05). However, medial patellofemoral pressure showed a significant increased patellofemoral contact pressure after MPFL reconstruction at a knee flexion angle during graft fixation of 15° (P = .027), 45° (P = .050, P = .044), and 75° (P = .039). Moreover, proximal/distal patellofemoral contact pressure revealed a significantly reduced contact pressure at 15° (P = .003), 30° (P = .009), 45° (P = .025), 75° (P = .021), and 90° (P = .022) of flexion distal after MPFL reconstruction compared with the intact knee. Lateral patellofemoral contact pressure was significantly reduced in all performed reconstructions (P < .05). The flexion angle during graft fixation for MPFL reconstruction did not have a significant impact on the overall patellofemoral contact pressure. However, selective medial, proximal, distal, and lateral patellofemoral contact pressure was significantly altered for all reconstructions. Fixation of the MPFL graft at 60° of flexion was able to most closely restore patellofemoral contact pressure compared with the intact knee. Based on the findings of the present study, fixation of the graft in anatomic reconstruction of the MPFL should be considered in 60° of flexion under low tension (2 N) to most closely restore patellofemoral contact pressure compared with the native knee. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  2. Effects of medially wedged foot orthoses on knee and hip joint running mechanics in females with and without patellofemoral pain syndrome.

    PubMed

    Boldt, Andrew R; Willson, John D; Barrios, Joaquin A; Kernozek, Thomas W

    2013-02-01

    We examined the effects of medially wedged foot orthoses on knee and hip joint mechanics during running in females with and without patellofemoral pain syndrome (PFPS). We also tested if these effects depend on standing calcaneal eversion angle. Twenty female runners with and without PFPS participated. Knee and hip joint transverse and frontal plane peak angle, excursion, and peak internal knee and hip abduction moment were calculated while running with and without a 6° full-length medially wedged foot orthoses. Separate 3-factor mixed ANOVAs (group [PFPS, control] x condition [medial wedge, no medial wedge] x standing calcaneal angle [everted, neutral, inverted]) were used to test the effect of medially wedged orthoses on each dependent variable. Knee abduction moment increased 3% (P = .03) and hip adduction excursion decreased 0.6° (P < .01) using medially wedged foot orthoses. No significant group x condition or calcaneal angle x condition effects were observed. The addition of medially wedged foot orthoses to standardized running shoes had minimal effect on knee and hip joint mechanics during running thought to be associated with the etiology or exacerbation of PFPS symptoms. These effects did not appear to depend on injury status or standing calcaneal posture.

  3. Validating Efficacy of Shea Nut Oil Extract in Knee Osteoarthritis Patients

    PubMed Central

    Lo, Sui-Foon; Wang, Yu-Chia; Chou, Tzu-Yi; Chang, Kang-Ming

    2013-01-01

    Objectives. To examine and investigate the efficacy of shea nut oil extract (SheaFlex75) in relation to knee osteoarthritis (OA). Methods. Thirty-three patients (age 63.6 ± 5.8 years) with knee OA were recruited. Real-time ultrasound imaging and surface electromyography were used to objectively assess the morphological changes and the activity of vastus medialis oblique (VMO) muscles during a 16-week intervention of SheaFlex75. The intraclass correlation coefficient (ICC) was calculated to examine the reliability of the interscans. A paired-sample t-test was used to compare the findings in different stages. The Spearman's rank correlation coefficient was used to examine the relationship between the relevant variables of OA and percentage of thickness change of VMO at different contraction levels. Results. The baseline findings showed strong correlation, suggesting that the reliability of interscans at pretest was high. The ability to contract the muscles of the knee to a 30% contraction level showed significant change between the baseline and after 16-week testing, both in terms of morphological changes and muscle activity. Pain scale reported a significant decrease at the 16th week. Conclusion. The results suggest that SheaFlex75 can relieve the symptoms of knee OA and can result in improvement of muscle control of the knee. PMID:24454485

  4. Exercise-Based Performance Enhancement and Injury Prevention for Firefighters: Contrasting the Fitness- and Movement-Related Adaptations to Two Training Methodologies.

    PubMed

    Frost, David M; Beach, Tyson A C; Callaghan, Jack P; McGill, Stuart M

    2015-09-01

    Using exercise to enhance physical fitness may have little impact on performers' movement patterns beyond the gym environment. This study examined the fitness and movement adaptations exhibited by firefighters in response to 2 training methodologies. Fifty-two firefighters were assigned to a movement-guided fitness (MOV), conventional fitness (FIT), or control (CON) group. Before and after 12 weeks of training, participants performed a fitness evaluation and laboratory-based test. Three-dimensional lumbar spine and frontal plane knee kinematics were quantified. Five whole-body tasks not included in the interventions were used to evaluate the transfer of training. FIT and MOV groups exhibited significant improvements in all aspects of fitness; however, only MOV exhibited improvements in spine and frontal plane knee motion control when performing each transfer task (effect sizes [ESs] of 0.2-1.5). FIT exhibited less controlled spine and frontal plane knee motions while squatting, lunging, pushing, and pulling (ES: 0.2-0.7). More MOV participants (43%) exhibited only positive posttraining changes (i.e., improved control), in comparison with FIT (30%) and CON (23%). Fewer negative posttraining changes were also noted (19, 25, and 36% for MOV, FIT, and CON). These findings suggest that placing an emphasis on how participants move while exercising may be an effective training strategy to elicit behavioral changes beyond the gym environment. For occupational athletes such as firefighters, soldiers, and police officers, this implies that exercise programs designed with a movement-oriented approach to periodization could have a direct impact on their safety and effectiveness by engraining desirable movement patterns that transfer to occupational tasks.

  5. Effects of a tele-prehabilitation program or an in-person prehabilitation program in surgical candidates awaiting total hip or knee arthroplasty: Protocol of a pilot single blind randomized controlled trial.

    PubMed

    Doiron-Cadrin, Patrick; Kairy, Dahlia; Vendittoli, Pascal-André; Lowry, Véronique; Poitras, Stéphane; Desmeules, François

    2016-12-15

    The accessibility for total joint arthroplasty often comes up against long wait lists, and may lead to deleterious effects for the awaiting patients. This pilot single blind randomized controlled trial aims to evaluate the impact of a telerehabilitation prehabilitation program before a hip or knee arthroplasty compared to in-person prehabilitation or to usual wait for surgery. Thirty-six patients on a wait list for a total hip or knee arthroplasty will be recruited and randomly assigned to one of three groups. The in-person prehabilitation group (n = 12) will receive a 12-week rehabilitation program (2 sessions/week) including education, exercises of the lower limb and cardiovascular training. Patients in the tele-prehabilitation group (n = 12) will receive the same intervention using a telecommunication software. The control group (n = 12) will be provided with the hospital's usual documentation before surgery. The Lower Extremity Functional Scale (LEFS) will be the primary outcome measure taken at baseline and at 12 weeks. Secondary measures will include self-reported function and quality of life as well as performance tests. A mixed-model, 2-way repeated-measure ANOVA will be used to analyse the effects of the rehabilitation programs. This pilot study is the first to evaluate the feasibility and the impact of a telerehabilitation prehabilitation program for patients awaiting a total joint arthroplasty. The results of this pilot-RCT will set the foundations for further research in the fields of rehabilitation and tele-medicine for patients suffering from lower limb osteoarthritis. ClinicalTrials.gov: NCT02636751.

  6. Evaluation of the Microsoft Kinect for screening ACL injury.

    PubMed

    Stone, Erik E; Butler, Michael; McRuer, Aaron; Gray, Aaron; Marks, Jeffrey; Skubic, Marjorie

    2013-01-01

    A study was conducted to evaluate the use of the skeletal model generated by the Microsoft Kinect SDK in capturing four biomechanical measures during the Drop Vertical Jump test. These measures, which include: knee valgus motion from initial contact to peak flexion, frontal plane knee angle at initial contact, frontal plane knee angle at peak flexion, and knee-to-ankle separation ratio at peak flexion, have proven to be useful in screening for future knee anterior cruciate ligament (ACL) injuries among female athletes. A marker-based Vicon motion capture system was used for ground truth. Results indicate that the Kinect skeletal model likely has acceptable accuracy for use as part of a screening tool to identify elevated risk for ACL injury.

  7. A pilot study of the effect of Kinesiology tape on knee proprioception after physical activity in healthy women.

    PubMed

    Hosp, Simona; Bottoni, Giuliamarta; Heinrich, Dieter; Kofler, Philipp; Hasler, Michael; Nachbauer, Werner

    2015-11-01

    Kinesiology tape has gained significant popularity in recent years and is widely used as an adjunct for treatment and prevention of musculoskeletal injuries. However, evidence regarding its influence on knee proprioception is scarce. The purpose of this study was to evaluate the effect of Kinesiology tape on knee proprioception after physical activity in healthy women. It was hypothesized that Kinesiology tape enhances knee proprioception. Longitudinal analysis, pretest-posttest design. Twelve young women with healthy knees were tested for knee proprioception without the use of Kinesiology tape and wearing Kinesiology tape at the knee. The joint position sense was measured at the start and after a 30-min uphill walking protocol on a treadmill. Outcome was the knee angle deviation. No significant difference of proprioceptive performance between the application with Kinesiology tape and without Kinesiology tape was found after uphill walking (p > 0.05). However, when the participants' results for knee angle deviation were graded into good (< 6.1°) and poor ( > 6.1°), Kinesiology tape significantly enhanced those with poor proprioceptive ability after uphill walking, compared to the untaped knee (p = 0.002). This study has shown that the application of Kinesiology tape did not improve knee proprioception in a group of healthy young women. However, it also has demonstrated that Kinesiology tape provided significant proprioceptive enhancement at the knee joint after uphill walking in healthy women with poor proprioceptive ability. This may support its use in sports medicine for preventing knee injuries. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  8. Dissecting the contribution of knee joint NGF to spinal nociceptive sensitization in a model of OA pain in the rat

    PubMed Central

    Sagar, D.R.; Nwosu, L.; Walsh, D.A.; Chapman, V.

    2015-01-01

    Summary Objective Although analgesic approaches targeting nerve growth factor (NGF) for the treatment of osteoarthritis (OA) pain remain of clinical interest, neurophysiological mechanisms by which NGF contribute to OA pain remain unclear. We investigated the impact of local elevation of knee joint NGF on knee joint, vs remote (hindpaw), evoked responses of spinal neurones in a rodent model of OA pain. Design In vivo spinal electrophysiology was carried out in anaesthetised rats with established pain behaviour and joint pathology following intra-articular injection of monosodium iodoacetate (MIA), vs injection of saline. Neuronal responses to knee joint extension and flexion, mechanical punctate stimulation of the peripheral receptive fields over the knee and at a remote site (ipsilateral hind paw) were studied before, and following, intra-articular injection of NGF (10 μg/50 μl) or saline. Results MIA-injected rats exhibited significant local (knee joint) and remote (lowered hindpaw withdrawal thresholds) changes in pain behaviour, and joint pathology. Intra-articular injection of NGF significantly (P < 0.05) increased knee extension-evoked firing of spinal neurones and the size of the peripheral receptive fields of spinal neurones (100% increase) over the knee joint in MIA rats, compared to controls. Intra-articular NGF injection did not significantly alter responses of spinal neurones following noxious stimulation of the ipsilateral hind paw in MIA-injected rats. Conclusion The facilitatory effects of intra-articular injection of NGF on spinal neurones receiving input from the knee joint provide a mechanistic basis for NGF mediated augmentation of OA knee pain, however additional mechanisms may contribute to the spread of pain to remote sites. PMID:25623624

  9. The Impact of Mechanical and Restricted Kinematic Alignment on Knee Anatomy in Total Knee Arthroplasty.

    PubMed

    Almaawi, Abdulaziz M; Hutt, Jonathan R B; Masse, Vincent; Lavigne, Martin; Vendittoli, Pascal-Andre

    2017-07-01

    Total knee arthroplasty (TKA), aiming at neutral mechanical alignment (MA), inevitably modifies the patient's native knee anatomy. Another option is kinematic alignment (KA), which aims to restore the original anatomy of the knee. The aim of this study was to evaluate the variations in lower limb anatomy of a patient population scheduled for TKA, and to assess the use of a restricted KA TKA protocol and compare the resulting anatomic modifications with the standard MA technique. A total of 4884 knee computed tomography scans were analyzed from a database of patients undergoing TKA with patient-specific instrumentation. The lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), and hip-knee-ankle angle (HKA) were measured. Bone resections were compared using a standard MA and a restricted KA aiming for independent tibial and femoral cuts of maximum ±5° deviation from the coronal mechanical axis and a resulting overall coronal HKA within ±3° of neutral. The mean preoperative MPTA was 2.9° varus, LDFA was 2.7° valgus, and overall HKA was 0.1° varus. Using our protocol, 2475 knees (51%) could have undergone KA without adjustment. To include 4062 cases (83%), mean corrections of 0.5° for MPTA and 0.3° for LDFA were needed, significantly less than with MA (3.3° for MPTA and 3.2° for LDFA; P < .001). The range of knee anatomy in patients scheduled for TKA is wide. MA leads to greater modifications of knee joint anatomy. To avoid reproducing extreme anatomy, the proposed restricted KA protocol provides an interesting hybrid option between MA and true KA. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Dissecting the contribution of knee joint NGF to spinal nociceptive sensitization in a model of OA pain in the rat.

    PubMed

    Sagar, D R; Nwosu, L; Walsh, D A; Chapman, V

    2015-06-01

    Although analgesic approaches targeting nerve growth factor (NGF) for the treatment of osteoarthritis (OA) pain remain of clinical interest, neurophysiological mechanisms by which NGF contribute to OA pain remain unclear. We investigated the impact of local elevation of knee joint NGF on knee joint, vs remote (hindpaw), evoked responses of spinal neurones in a rodent model of OA pain. In vivo spinal electrophysiology was carried out in anaesthetised rats with established pain behaviour and joint pathology following intra-articular injection of monosodium iodoacetate (MIA), vs injection of saline. Neuronal responses to knee joint extension and flexion, mechanical punctate stimulation of the peripheral receptive fields over the knee and at a remote site (ipsilateral hind paw) were studied before, and following, intra-articular injection of NGF (10 μg/50 μl) or saline. MIA-injected rats exhibited significant local (knee joint) and remote (lowered hindpaw withdrawal thresholds) changes in pain behaviour, and joint pathology. Intra-articular injection of NGF significantly (P < 0.05) increased knee extension-evoked firing of spinal neurones and the size of the peripheral receptive fields of spinal neurones (100% increase) over the knee joint in MIA rats, compared to controls. Intra-articular NGF injection did not significantly alter responses of spinal neurones following noxious stimulation of the ipsilateral hind paw in MIA-injected rats. The facilitatory effects of intra-articular injection of NGF on spinal neurones receiving input from the knee joint provide a mechanistic basis for NGF mediated augmentation of OA knee pain, however additional mechanisms may contribute to the spread of pain to remote sites. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Hydrotherapy improves pain and function in older women with knee osteoarthritis: a randomized controlled trial.

    PubMed

    Dias, João Marcos; Cisneros, Lígia; Dias, Rosângela; Fritsch, Carolina; Gomes, Wellington; Pereira, Leani; Santos, Mary Luci; Ferreira, Paulo Henrique

    Currently, there is poor evidence of the effect of hydrotherapy alone on patients with hip or knee osteoarthritis. The study aimed to assess the impact of hydrotherapy on pain, function, and muscle function in older women with knee osteoarthritis. A randomized controlled trial was conducted to evaluate the efficacy of hydrotherapy in women with knee osteoarthritis. Seventy-three women aged 65 and older were randomized to hydrotherapy (n=36) or a control group (n=37). The hydrotherapy group received the intervention program in a heated pool (twice per week for six weeks) and an educational protocol while the control group received an educational protocol only. Primary outcomes (before and post-treatment) were pain intensity (0-100) and function (0-100), assessed with the WOMAC questionnaire. Secondary outcomes (before and post-treatment) were knee extensor and knee flexor muscle performance (strength, power, and endurance), assessed by an isokinetic dynamometer. The magnitude of change between the groups for the outcomes was calculated using linear regression models adjusted by baseline outcome values. The hydrotherapy group had better outcomes for pain (adjusted mean difference=11 points, 95% CI: 3-18) and function (adjusted mean difference=12 points, 95% CI: 5-18). Patients receiving hydrotherapy had better performance for knee flexor and extensor strength, knee flexor power, and knee extensor endurance. Older women with knee osteoarthritis are likely to have benefits from a course of hydrotherapy exercises. Registry of clinical trials (Trial number RBR-8F57KR) - http://www.ensaiosclinicos.gov.br/rg/RBR-8f57kr/. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  12. Preoperative physiotherapy and short-term functional outcomes of primary total knee arthroplasty.

    PubMed

    Mat Eil Ismail, Mohd Shukry; Sharifudin, Mohd Ariff; Shokri, Amran Ahmed; Ab Rahman, Shaifuzain

    2016-03-01

    Physiotherapy is an important part of rehabilitation following arthroplasty, but the impact of preoperative physiotherapy on functional outcomes is still being studied. This randomised controlled trial evaluated the effect of preoperative physiotherapy on the short-term functional outcomes of primary total knee arthroplasty (TKA). 50 patients with primary knee osteoarthritis who underwent unilateral primary TKA were randomised into two groups: the physiotherapy group (n = 24), whose patients performed physical exercises for six weeks immediately prior to surgery, and the nonphysiotherapy group (n = 26). All patients went through a similar physiotherapy regime in the postoperative rehabilitation period. Functional outcome assessment using the algofunctional Knee Injury and Osteoarthritis Outcome Score (KOOS) scale and range of motion (ROM) evaluation was performed preoperatively, and postoperatively at six weeks and three months. Both groups showed a significant difference in all algofunctional KOOS subscales (p < 0.001). The mean score difference at six weeks and three months was not significant in the sports and recreational activities subscale for both groups (p > 0.05). Significant differences were observed in the time-versus-treatment analysis between groups for the symptoms (p = 0.003) and activities of daily living (p = 0.025) subscales. No significant difference in ROM was found when comparing preoperative measurements and those at three months following surgery, as well as in time-versus-treatment analysis (p = 0.928). Six-week preoperative physiotherapy showed no significant impact on short-term functional outcomes (KOOS subscales) and ROM of the knee following primary TKA. Copyright: © Singapore Medical Association.

  13. What Strains the Anterior Cruciate Ligament During a Pivot Landing?

    PubMed Central

    Oh, Youkeun K.; Lipps, David B.; Ashton-Miller, James A.; Wojtys, Edward M.

    2015-01-01

    Background The relative contributions of an axial tibial torque and frontal plane moment to anterior cruciate ligament (ACL) strain during pivot landings are unknown. Hypothesis The peak normalized relative strain in the anteromedial (AM) bundle of the ACL is affected by the direction of the axial tibial torque but not by the direction of the frontal plane moment applied concurrently during a simulated jump landing. Study Design Controlled and descriptive laboratory studies. Methods Fifteen adult male knees with pretensioned knee muscle-tendon unit forces were loaded under a simulated pivot landing test. Compression, flexion moment, internal or external tibial torque, and knee varus or valgus moment were simultaneously applied to the distal tibia while recording the 3D knee loads and tibiofemoral kinematics. The AM-ACL relative strain was measured using a 3-mm differential variable reluctance transducer. The results were analyzed using nonparametric Wilcoxon signed–rank tests. A 3D dynamic biomechanical knee model was developed using ADAMS and validated to help interpret the experimental results. Results The mean (SD) peak AM-ACL relative strain was 192% greater (P <.001) under the internal tibial torque combined with a knee varus or valgus moment (7.0% [3.9%] and 7.0% [4.1%], respectively) than under external tibial torque with the same moments (2.4% [2.5%] and 2.4% [3.2%], respectively). The knee valgus moment augmented the AM-ACL strain due to the slope of the tibial plateau inducing mechanical coupling (ie, internal tibial rotation and knee valgus moment); this augmentation occurred before medial knee joint space opening. Conclusion An internal tibial torque combined with a knee valgus moment is the worst-case ACL loading condition. However, it is the internal tibial torque that primarily causes large ACL strain. Clinical Relevance Limiting the maximum coefficient of friction between the shoe and playing surface should limit the peak internal tibial torque that can be applied to the knee during jump landings, thereby reducing peak ACL strain and the risk for noncontact injury. PMID:22223717

  14. Clinical knee findings in floor layers with focus on meniscal status.

    PubMed

    Rytter, Søren; Jensen, Lilli Kirkeskov; Bonde, Jens Peter

    2008-10-22

    The aim of this study was to examine the prevalence of self-reported and clinical knee morbidity among floor layers compared to a group of graphic designers, with special attention to meniscal status. We obtained information about knee complaints by questionnaire and conducted a bilateral clinical and radiographic knee examination in 134 male floor layers and 120 male graphic designers. After the exclusion of subjects with reports of earlier knee injuries the odds ratio (OR) with 95% confidence intervals (CI) of knee complaints and clinical findings were computed among floor layers compared to graphic designers, using logistic regression. Estimates were adjusted for effects of body mass index, age and knee straining sports. Using radiographic evaluations, we conducted side-specific sensitivity analyses regarding clinical signs of meniscal lesions after the exclusion of participants with tibiofemoral (TF) osteoarthritis (OA). Reports of knee pain (OR = 2.7, 95% CI = 1.5-4.6), pain during stair walking (OR = 2.2, 95% CI = 1.3-3.9) and symptoms of catching of the knee joint (OR = 2.9, 95% CI = 1.4-5.7) were more prevalent among floor layers compared to graphic designers. Additionally, significant more floor layers than graphic designers had clinical signs suggesting possible meniscal lesions: a positive McMurray test (OR = 2.4, 95% CI = 1.1-5.0) and TF joint line tenderness (OR = 5.4, 95% CI = 2.4-12.0). Excluding floor layers (n = 22) and graphic designers (n = 15) with radiographic TF OA did not alter this trend between the two study groups: a positive McMurray test (OR = 2.2, 95% CI = 1.0-4.9), TF joint line tenderness (OR = 5.0, 95% CI = 2.0-12.5). Results indicate that floor layers have a high prevalence of both self-reported and clinical knee morbidity. Clinical knee findings suggesting possible meniscal lesions were significant more prevalent among floor layers compared to a group of low-level exposed graphic designers and an association with occupational kneeling could be possible. However, causality cannot be confirmed due to the cross-sectional study design.

  15. The Impact of the Medicaid Health Care-Associated Condition Program on Mediastinitis Following Coronary Artery Bypass Graft

    PubMed Central

    Hsu, Heather; Kawai, Alison Tse; Wang, Rui; Jentzsch, Maximilian S.; Rhee, Chanu; Horan, Kelly; Jin, Robert; Goldmann, Donald; Lee, Grace M.

    2018-01-01

    Objective In 2012, the Centers for Medicare and Medicaid Services expanded a 2008 program that eliminated additional Medicare payment for mediastinitis following coronary artery bypass graft (CABG) to include Medicaid. We aimed to evaluate the impact of this Medicaid program on mediastinitis rates reported by the National Healthcare Safety Network (NHSN) compared with rates of a condition not targeted by the program (deep space surgical site infection [SSI] after knee replacement). Design interrupted time series with comparison group. Methods We included surveillance data from non-federal acute care hospitals participating in NHSN and reporting CABG or knee replacement outcomes from 1/2009–6/2017. We examined the Medicaid program’s impact on NHSN-reported infection rates, adjusting for secular trends. Data analysis used generalized estimating equations with robust sandwich variance estimators. Results During the study period, 196 study hospitals reported 273,984 CABGs to NHSN, resulting in 970 mediastinitis cases (0.35%); 294 hospitals reported 555,395 knee replacements, with 1,751 resultant deep space SSIs (0.32%). There were no significant changes in incidence of either condition during the study. Mediastinitis models showed no effect of the 2012 Medicaid program on either secular trend during the post- vs. pre-program time periods (p-value=0.70) or immediate program effect (p-value=0.83). Results were similar in sensitivity analyses when adjusting for hospital characteristics, restricting to hospitals with consistent NHSN reporting, or incorporating a program implementation roll-in period. Knee replacement models also showed no program effect. Conclusions The 2012 Medicaid program to eliminate additional payments for mediastinitis following CABG had no impact on reported mediastinitis rates. PMID:29669607

  16. Knee Instability and Basic and Advanced Function Decline in Knee Osteoarthritis.

    PubMed

    Sharma, Leena; Chmiel, Joan S; Almagor, Orit; Moisio, Kirsten; Chang, Alison H; Belisle, Laura; Zhang, Yunhui; Hayes, Karen W

    2015-08-01

    Manifestations of instability in knee osteoarthritis (OA) include low overall knee confidence, low confidence that the knees will not buckle, buckling, and excessive motion during gait. Confidence and buckling may particularly influence activity choices, contributing to events leading to disability. Buckling is more likely to affect advanced than basic functional tasks. In this prospective longitudinal study, we tested the hypothesis that overall knee confidence, buckling confidence, buckling, and frontal plane motion during gait are associated with advanced 2-year function outcomes in persons with knee OA. Persons with knee OA were queried about overall knee confidence (higher score = worse confidence), buckling confidence, and knee buckling, and underwent quantitative gait analysis to quantify varus-valgus excursion and angular velocity. Physical function was assessed using the Late-Life Function and Disability Instrument Basic and Advanced Lower Extremity Domain scores. Logistic regression was used to evaluate the relationship between baseline instability measures and baseline-to-2-year function outcome, adjusting for potential confounders. The sample was comprised of 212 persons (mean age 64.6 years, 76.9% women). Buckling was significantly associated with poor advanced function outcome (adjusted odds ratio [OR] 2.08, 95% confidence interval [95% CI] 1.03-4.20) but not basic function outcome. Overall knee confidence was significantly associated with advanced outcome (adjusted OR 1.65, 95% CI 1.01-2.70), while associations between buckling confidence and both outcomes approached significance. Neither varus-valgus excursion nor angular velocity during gait was associated with either outcome. Knee buckling and low knee confidence were each associated with poor 2-year advanced function outcomes. Current treatment does not address these modifiable factors; interventions to address them may improve outcome in knee OA. © 2015, American College of Rheumatology.

  17. Cultural adaptation and validation of a German version of the Arthritis Impact Measurement Scales (AIMS2).

    PubMed

    Rosemann, T; Szecsenyi, J

    2007-10-01

    To validate a translated and culturally adapted version of the Arthritis Impact Measurement Scale (AIMS) 2 in primary care patients with osteoarthritis (OA) of the hip and knee. The AIMS2 was translated into German and culturally adapted. The questionnaire then was administered to 220 primary care patients with OA of the knee or hip. Two hundred and nine questionnaires were returned and analysed. Test-retest reliability was tested in 50 randomly selected patients, of those 42 completed the questionnaire after 2 weeks for a second time. Item-scale correlations were reasonably good as well as the discriminative power of separate scales. The assessment of internal consistency reliability also revealed satisfactory values; Cronbach's alpha was 0.77 or higher for all scales. The test-retest reliability, estimated in an intraclass correlation coefficient (ICC), exceeded 0.90, except the "social activities" scale (0.87). Since only patients with OA of the lower limb were enrolled, substantial floor effects occurred in the "arm function" (28.2%) and the "hand and finger function" scale (29.2%). The principal factor analysis confirmed the postulated three-factor structure with a physical, physiological and social dimension, explaining 48.5%, 13.9% and 6.8% of the variation, respectively. External validity was assessed by calculating correlations to the Western Ontario and MacMaster (WOMAC) osteoarthritis questionnaire a pain visual analogue scale (VAS) and the Kellgren score as well as to disease duration. Spearman's "R" achieved satisfactory values for the corresponding WOMAC scales and the pain-VAS. Correlations with disease duration as well as with the radiological grading were low. The GERMAN-AIMS2 is a reliable and valid instrument to assess the quality of life (QoL) in primary care patients suffering from OA.

  18. Seasonality of service provision in hip and knee surgery: a possible contributor to waiting times? A time series analysis.

    PubMed

    Upshur, Ross E G; Moineddin, Rahim; Crighton, Eric J; Mamdani, Muhammad

    2006-03-01

    The question of how best to reduce waiting times for health care, particularly surgical procedures such as hip and knee replacements is among the most pressing concern of the Canadian health care system. The objective of this study was to test the hypothesis that significant seasonal variation exists in the performance of hip and knee replacement surgery in the province of Ontario. We performed a retrospective, cross-sectional time series analysis examining all hip and knee replacement surgeries in people over the age of 65 in the province of Ontario, Canada between 1992 and 2002. The main outcome measure was monthly hospitalization rates per 100,000 population for all hip and knee replacements. There was a marked increase in the rate of hip and knee replacement surgery over the 10-year period as well as an increasing seasonal variation in surgeries. Highly significant (Fisher Kappa = 16.05, p < 0.01; Bartlett-Kolmogorov-Smirnov Test = 0.31, p < 0.01) and strong (R2Autoreg = 0.85) seasonality was identified in the data. Holidays and utilization caps appear to exert a significant influence on the rate of service provision. It is expected that waiting times for hip and knee replacement could be reduced by reducing seasonal fluctuations in service provision and benchmarking services to peak delivery. The results highlight the importance of system behaviour in seasonal fluctuation of service delivery.

  19. Seasonality of service provision in hip and knee surgery: A possible contributor to waiting times? A time series analysis

    PubMed Central

    Upshur, Ross EG; Moineddin, Rahim; Crighton, Eric J; Mamdani, Muhammad

    2006-01-01

    Background The question of how best to reduce waiting times for health care, particularly surgical procedures such as hip and knee replacements is among the most pressing concern of the Canadian health care system. The objective of this study was to test the hypothesis that significant seasonal variation exists in the performance of hip and knee replacement surgery in the province of Ontario. Methods We performed a retrospective, cross-sectional time series analysis examining all hip and knee replacement surgeries in people over the age of 65 in the province of Ontario, Canada between 1992 and 2002. The main outcome measure was monthly hospitalization rates per 100 000 population for all hip and knee replacements. Results There was a marked increase in the rate of hip and knee replacement surgery over the 10-year period as well as an increasing seasonal variation in surgeries. Highly significant (Fisher Kappa = 16.05, p < 0.01; Bartlett-Kolmogorov-Smirnov Test = 0.31, p < 0.01) and strong (R2Autoreg = 0.85) seasonality was identified in the data. Conclusion Holidays and utilization caps appear to exert a significant influence on the rate of service provision. It is expected that waiting times for hip and knee replacement could be reduced by reducing seasonal fluctuations in service provision and benchmarking services to peak delivery. The results highlight the importance of system behaviour in seasonal fluctuation of service delivery. PMID:16509992

  20. Importance of tibial slope for stability of the posterior cruciate ligament deficient knee.

    PubMed

    Giffin, J Robert; Stabile, Kathryne J; Zantop, Thore; Vogrin, Tracy M; Woo, Savio L-Y; Harner, Christopher D

    2007-09-01

    Previous studies have shown that increasing tibial slope can shift the resting position of the tibia anteriorly. As a result, sagittal osteotomies that alter slope have recently been proposed for treatment of posterior cruciate ligament (PCL) injuries. Increasing tibial slope with an osteotomy shifts the resting position anteriorly in a PCL-deficient knee, thereby partially reducing the posterior tibial "sag" associated with PCL injury. This shift in resting position from the increased slope causes a decrease in posterior tibial translation compared with the PCL-deficient knee in response to posterior tibial and axial compressive loads. Controlled laboratory study. Three knee conditions were tested with a robotic universal force-moment sensor testing system: intact, PCL-deficient, and PCL-deficient with increased tibial slope. Tibial slope was increased via a 5-mm anterior opening wedge osteotomy. Three external loading conditions were applied to each knee condition at 0 degrees, 30 degrees, 60 degrees, 90 degrees, and 120 degrees of knee flexion: (1) 134-N anterior-posterior (A-P) tibial load, (2) 200-N axial compressive load, and (3) combined 134-N A-P and 200-N axial loads. For each loading condition, kinematics of the intact knee were recorded for the remaining 5 degrees of freedom (ie, A-P, medial-lateral, and proximal-distal translations, internal-external and varus-valgus rotations). Posterior cruciate ligament deficiency resulted in a posterior shift of the tibial resting position to 8.4 +/- 2.6 mm at 90 degrees compared with the intact knee. After osteotomy, tibial slope increased from 9.2 degrees +/- 1.0 degrees in the intact knee to 13.8 degrees +/- 0.9 degrees. This increase in slope reduced the posterior sag of the PCL-deficient knee, shifting the resting position anteriorly to 4.0 +/- 2.0 mm at 90 degrees. Under a 200-N axial compressive load with the osteotomy, an additional increase in anterior tibial translation to 2.7 +/- 1.7 mm at 30 degrees was observed. Under a 134-N A-P load, the osteotomy did not significantly affect total A-P translation when compared with the PCL-deficient knee. However, because of the anterior shift in resting position, there was a relative decrease in posterior tibial translation and increase in anterior tibial translation. Increasing tibial slope in a PCL-deficient knee reduces tibial sag by shifting the resting position of the tibia anteriorly. This sag is even further reduced when the knee is subjected to axial compressive loads. These data suggest that increasing tibial slope may be beneficial for patients with PCL-deficient knees.

  1. Should plain X-rays be routinely performed after blunt knee trauma? A prospective analysis.

    PubMed

    Jenny, Jean-Yves; Boeri, Cyril; El Amrani, Hakima; Dosch, Jean-Claude; Dupuis, Michel; Moussaoui, Akli; Mairot, Fabrice

    2005-06-01

    We tested the hypothesis that it was possible to decrease the number of performed x-rays after a knee trauma without delayed fracture diagnosis by using the Ottawa knee rules. Patients had routine x-rays of the injured knee during the first stage of the study and selective x-rays during the second stage. All patients were followed up to 6 months after the trauma. 138 patients were included in the first stage; 57 had negative Ottawa criteria: no fracture was observed; following the Ottawa rules, 41% of the x-rays could have been avoided. 178 patients were included in the second stage; 63 patients had negative Ottawa criteria: no fracture was diagnosed during the whole follow-up; 35% of the x-rays have been avoided. Ottawa rules allowed decreasing the number of x-rays performed after a knee trauma by 35% with a sensitivity for a knee fracture detection of 100%.

  2. Influence of conformity on the wear of total knee replacement: An experimental study

    PubMed Central

    Brockett, Claire L; Carbone, Silvia; Fisher, John; Jennings, Louise M

    2017-01-01

    Wear of total knee replacement continues to be a significant factor influencing the clinical longevity of implants. Historically, failure due to delamination and fatigue directed design towards more conforming inserts to reduce contact stress. As new generations of more oxidatively stable polyethylene have been developed, more flexibility in bearing design has been introduced. The aim of this study was to investigate the effect of insert conformity on the wear performance of a fixed bearing total knee replacement through experimental simulation. Two geometries of insert were studied under standard gait conditions. There was a significant reduction in wear with reducing implant conformity. This study has demonstrated that bearing conformity has a significant impact on the wear performance of a fixed bearing total knee replacement, providing opportunities to improve clinical performance through enhanced material and design selection. PMID:29251167

  3. Knee Pain and Future Self-Reliance in Older Adults: Evidence From a Community-Based 3-Year Cohort Study in Japan

    PubMed Central

    Nishiwaki, Yuji; Michikawa, Takehiro; Yamada, Mutsuko; Eto, Norihito; Takebayashi, Toru

    2011-01-01

    Background Although knee pain is common in older persons and can cause ambulatory limitation, its impact on self-reliance has rarely been examined in Japan, particularly in a community setting. The aim of this 3-year cohort study was to investigate the association of knee pain with dependence in activities of daily living (ADL) and mortality in community-dwelling older Japanese adults. Methods In 2005, presence of knee pain was assessed by a home visit survey of 1391 older adults aged 65 years or older (participation proportion = 97.3%). A total of 1265 participants who were ADL-independent at baseline were followed for 3 years, and information on outcomes, namely death and dependence in ADL, was collected. Results Participants who always had knee pain were more likely to become dependent in ADL than those who reported no knee pain (multivariate-adjusted OR, 1.98; 95% CI, 1.03–3.83); however, always having knee pain was not associated with mortality or a composite outcome of ADL dependence and death. Further analyses of each component of ADL dependence revealed that knee pain was associated with a need for assistance at home (long-term care eligibility, bathing, dressing, and transferring), but not with institutionalization. Conclusions The participants were highly representative of the target population and the rate of follow-up was almost perfect (99.4%). The results suggest that knee pain is associated with future dependence in ADL, particularly a need for assistance at home. PMID:21422701

  4. Tibial rotation kinematics subsequent to knee arthroplasty

    PubMed Central

    Collins, Duane J.; Khatib, Yasser H.; Parker, David A.; Jenkin, Deanne E.; Molnar, Robert B.

    2015-01-01

    Background The use of computer assisted joint replacement has facilitated precise intraoperative measurement of knee kinematics. The changes in “screw home mechanism” (SHM) resulting from Total Knee Arthroplasty (TKA) with different prostheses and constraints has not yet been accurately described. Methods A pilot study was first completed. Intraoperative kinematic data was collected two groups of 15 patients receiving different prostheses. Results On average, patients lost 5.3° of ER (SD = 6.1°). There was no significant difference between the prostheses or different prosthetic constraints. Conclusions There significant loss of SHM after TKA. Further research is required to understand its impact on patient function. PMID:25829754

  5. Validity and reliability of the Dutch translation of the VISA-P questionnaire for patellar tendinopathy.

    PubMed

    Zwerver, Johannes; Kramer, Tamara; van den Akker-Scheek, Inge

    2009-08-11

    The VISA-P questionnaire evaluates severity of symptoms, knee function and ability to play sports in athletes with patellar tendinopathy. This English-language self-administered brief patient outcome score was developed in Australia to monitor rehabilitation and to evaluate outcome of clinical studies. Aim of this study was to translate the questionnaire into Dutch and to study the reliability and validity of the Dutch version of the VISA-P. The questionnaire was translated into Dutch according to internationally recommended guidelines. Test-retest reliability was determined in 99 students with a time interval of 2.5 weeks. To determine discriminative validity of the Dutch VISA-P, 18 healthy students, 15 competitive volleyball players (at-risk population), 14 patients with patellar tendinopathy, 6 patients who had surgery for patellar tendinopathy, 17 patients with knee injuries other than patellar tendinopathy, and 9 patients with symptoms unrelated to their knees completed the Dutch VISA-P. The Dutch VISA-P questionnaire showed satisfactory test-retest reliability (ICC=0.74). The mean (+/-SD) VISA-P scores were 95 (+/-9) for the healthy students, 89 (+/-11) for the volleyball players, 58 (+/-19) for patients with patellar tendinopathy, and 56 (+/-21) for athletes who had surgery for patellar tendinopathy. Patients with other knee injuries or symptoms unrelated to the knee scored 62 (+/-24) and 77 (+/-24). The translated Dutch version of the VISA-P questionnaire is equivalent to its original version, has satisfactory test-retest reliability and is a valid score to evaluate symptoms, knee function and ability to play sports of Dutch athletes with patellar tendinopathy.

  6. Trochleoplasty as a Solitary Treatment for Recurrent Patellar Dislocation Results in Good Clinical Outcome in Adolescents.

    PubMed

    Camathias, Carlo; Studer, Katrin; Kiapour, Ata; Rutz, Erich; Vavken, Patrick

    2016-11-01

    The essential static patellar stabilizer is a normal-shaped trochlear groove. A dysplastic groove destabilizes the patella. Trochleoplasty approaches this underlying condition and reshapes the trochlea. However, studies have reported on trochleoplasty for revision cases or as accompanied by other interventions. The effect of trochleoplasty alone remains unexplained. To introduce trochleoplasty as a stand-alone treatment for recurrent patellar dislocation and to compare its pre- to postoperative functional and clinical variables. Case series; Level of evidence, 4. A trochleoplasty was performed in 50 knees (27 right) in 44 patients (30 females; mean ± SD age, 15.6 ± 2.0 years). The indication for surgery was recurrent patellar dislocation not responding to nonoperative treatment (>6 months), with types B through D dysplasia and closed or closing physes in adolescents aged 10 to 20 years. Assessment included J-sign and apprehension test, Kujala and Lysholm scores, patients' subjective assessment and activity level according to the International Knee Documentation Committee questionnaire, and patients' overall satisfaction. The Caton-Deschamps ratio and the lateral condyle index were measured. Pre- versus postoperative values were compared with a paired Wilcoxon signed-rank test. The minimum follow-up was 24 months (33 ± 10.6 months). The Kujala score improved from 71 preoperatively to 92 postoperatively (P < .001) and the Lysholm score from 71 to 95 (P < .001). Patients' subjective assessment improved at the final follow-up as compared with that preoperatively (P < .001). Most patients enhanced their activity (P < .001), and their overall satisfaction increased postoperatively (P < .001). Preoperatively, there was a positive J-sign in 45 knees and a positive apprehension test in 41 knees. Both markers disappeared postoperatively in 39 and 33 knees, respectively, leaving 6 knees with a positive J-sign and 8 knees with a positive apprehension test (P < .001). One patella redislocated postoperatively after 38 months. Four patients required a single arthroscopic debridement. In this study, trochleoplasty as a solitary treatment for recurrent patellofemoral dislocations in patients with trochlear dysplasia resulted in good clinical outcomes if severe torsional and axial malalignment was excluded. Kujala and Lysholm scores increased postoperatively, as well as subjective International Knee Documentation Committee assessment of outcomes, activity level, and overall satisfaction. © 2016 The Author(s).

  7. Effect of rest interval on strength recovery in young and old women.

    PubMed

    Theou, Olga; Gareth, Jones R; Brown, Lee E

    2008-11-01

    This study compares the effects of rest intervals on isokinetic muscle torque recovery between sets of a knee extensor and flexor exercise protocol in physically active younger and older women. Twenty young (22.4 +/- 1.7 years) and 16 older (70.7 +/- 4.3 years) women performed three sets of eight maximum repetitions of knee extension/flexion at 60 degrees x s(-1). The rest interval between sets was 15, 30, and 60 seconds and was randomly assigned across three testing days. No significant interaction of rest by set by age group was observed. There was a significant decline in mean knee extensor torque when 15- and 30-second rest intervals were used between sets, but not when a 60-second rest interval was applied for both the young and the old women. No significant decline for mean knee flexor torque was observed in the older women when a 30-second rest interval was used, whereas a longer 60-second rest interval was required in younger women. Active younger and older women require similar rest intervals between sets of a knee extensor exercise (60 seconds) for complete recovery. However, older women recovered faster (30 seconds) than younger women (60 seconds) between sets of a knee flexor exercise. The exercise-to-rest ratio for knee extensors was similar for young and old women (1:2). Old women required only a 1:1 exercise-to-rest ratio for knee flexor recovery, whereas younger women required a longer 1:2 exercise-to-rest ratio. The results of the present study are specific to isokinetic testing and training and are more applicable in rehabilitation and research settings. Practitioners should consider age and gender when prescribing rest intervals between sets.

  8. Knee joint position sense ability in elite athletes who have returned to international level play following ACL reconstruction: A cross-sectional study.

    PubMed

    Relph, Nicola; Herrington, Lee

    2016-12-01

    Following an ACL injury, reconstruction (ACL-R) and rehabilitation, athletes may return to play with a proprioceptive deficit. However, literature is lacking to support this hypothesis in elite athletic groups who have returned to international levels of performance. It is possible the potentially heightened proprioceptive ability evidenced in athletes may negate a deficit following injury. The purpose of this study was to consider the effects of ACL injury, reconstruction and rehabilitation on knee joint position sense (JPS) on a group of elite athletes who had returned to international performance. Using a cross-sectional design ten elite athletes with ACL-R and ten controls were evaluated. JPS was tested into knee extension and flexion using absolute error scores. Average data with 95% confidence intervals between the reconstructed, contralateral and uninjured control knees were analyzed using t-tests and effect sizes. The reconstructed knee of the injured group demonstrated significantly greater angle of error scores when compared to the contralateral and uninjured control into knee flexion (p=0.0001, r=0.98) and knee extension (p=0.0001, r=0.91). There were no significant differences between the contralateral uninjured knee of the injured group and the uninjured control group. Elite athletes who have had an ACL injury, reconstruction, rehabilitation and returned to international play demonstrate lower JPS ability compared to control groups. It is unclear if this deficiency affects long-term performance or secondary injury and re-injury problems. In the future physical therapists should monitor athletes longitudinally when they return to play. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Sonomyography Analysis on Thickness of Skeletal Muscle During Dynamic Contraction Induced by Neuromuscular Electrical Stimulation: A Pilot Study.

    PubMed

    Qiu, Shuang; Feng, Jing; Xu, Jiapeng; Xu, Rui; Zhao, Xin; Zhou, Peng; Qi, Hongzhi; Zhang, Lixin; Ming, Dong

    2017-01-01

    Neuromuscular electrical stimulation (NMES) that stimulates skeletal muscles to induce contractions has been widely applied to restore functions of paralyzed muscles. However, the architectural changes of stimulated muscles induced by NMES are still not well understood. The present study applies sonomyography (SMG) to evaluate muscle architecture under NMES-induced and voluntary movements. The quadriceps muscles of seven healthy subjects were tested for eight cycles during an extension exercise of the knee joint with/without NMES, and SMG and the knee joint angle were recorded during the process of knee extension. A least squares support vector machine (LS-SVM) LS-SVM model was developed and trained using the data sets of six cycles collected under NMES, while the remaining data was used to test. Muscle thickness changes were extracted from ultrasound images and compared between NMES-induced and voluntary contractions, and LS-SVM was used to model a relationship between dynamical knee joint angles and SMG signals. Muscle thickness showed to be significantly correlated with joint angle in NMES-induced contractions, and a significant negative correlation was observed between Vastus intermedius (VI) thickness and rectus femoris (RF) thickness. In addition, there was a significant difference between voluntary and NMES-induced contractions . The LS-SVM model based on RF thickness and knee joint angle provided superior performance compared with the model based on VI thickness and knee joint angle or total thickness and knee joint angle. This suggests that a strong relation exists between the RF thickness and knee joint angle. These results provided direct evidence for the potential application of RF thickness in optimizing NMES system as well as measuring muscle state under NMES.

  10. Improvement in upper leg muscle strength underlies beneficial effects of exercise therapy in knee osteoarthritis: secondary analysis from a randomised controlled trial.

    PubMed

    Knoop, J; Steultjens, M P M; Roorda, L D; Lems, W F; van der Esch, M; Thorstensson, C A; Twisk, J W R; Bierma-Zeinstra, S M A; van der Leeden, M; Dekker, J

    2015-06-01

    Although exercise therapy is effective for reducing pain and activity limitations in patients with knee osteoarthritis (OA), the underlying mechanisms are unclear. This study aimed to evaluate if improvements in neuromuscular factors (i.e. upper leg muscle strength and knee proprioception) underlie the beneficial effects of exercise therapy in patients with knee OA. Secondary analyses from a randomised controlled trial, with measurements at baseline, 6 weeks, 12 weeks and 38 weeks. Rehabilitation centre. One hundred and fifty-nine patients diagnosed with knee OA. Exercise therapy. Changes in pain [numeric rating scale (NRS)] and activity limitations [Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) physical function subscale and get-up-and-go test] during the study period. Independent variables were changes in upper leg muscle strength and knee joint proprioception (i.e. motion sense) during the study period. Longitudinal regression analyses (generalised estimating equation) were performed to analyse associations between changes in upper leg muscle strength and knee proprioception with changes in pain and activity limitations. Improved muscle strength was significantly associated with reductions in NRS pain {B coefficient -2.5 [95% confidence interval (CI) -3.7 to -1.4], meaning that every change of 1 unit of strength was linked to a change of -2.5 units of pain}, WOMAC physical function (-8.8, 95% CI -13.4 to -4.2) and get-up-and-go test (-1.7, 95% CI -2.4 to -1.0). Improved proprioception was not significantly associated with better outcomes of exercise therapy (P>0.05). Upper leg muscle strengthening is one of the mechanisms underlying the beneficial effects of exercise therapy in patients with knee OA. Copyright © 2014 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  11. Functional health of patients with knee osteoarthritis in a family medicine clinic in Ibadan.

    PubMed

    Ilori, T; Ladipo, M M; Ogunbode, A M

    2016-09-01

    Patients with knee osteoarthritis experience pain and functional impairment, which impacts upon activities of daily living ultimately leading to a loss of functional independence and low quality- of-life. This study therefore aimed at evaluating the functional health status of patients with knee osteoarthritis in the Family Medicine clinic, University College Hospital, Ibadan, Nigeria. A cross-sectional study was conducted on 270 eligible respondents between January and March 2011. The Ibadan Knee/Hip Osteoarthritis Measure (IKHOAM) was administered after screening with the knee pain screening tool (KNEST). Respondents'Socio- demographic characteristics and knee pain intensity ratings were also recorded. The age range of respondents in the study was from 28 years to 85 years with a female: male ratio 5:1. Out of the 270 respondents studied, 146 (54.1%) reported restriction in performing duties at work. One hundred and twenty seven respondents (47.0%) needed some assistance in walking outside the house for 15 to 20 minutes, whilst 195 (72.2%) required some assistance in climbing stairs. Thirty four (12.6%) of Muslims and 77 (28.5%) of Christians could not kneel to pray. Males are twice more likely to have a better functional health than females (OR= 2.1, 95% CI= 1.0- 4.6, p=0.046). Knee osteoarthritis significantly impairs activities of daily living, especially some socio-cultural and religious practices of respondents. Therefore in addition to treating the knee symptoms, removing environmental barriers may reduce immobility within and outside the home thereby improving functionality.

  12. Optimum Drop Jump Height in Division III Athletes: Under 75% of Vertical Jump Height.

    PubMed

    Peng, Hsien-Te; Khuat, Cong Toai; Kernozek, Thomas W; Wallace, Brian J; Lo, Shin-Liang; Song, Chen-Yi

    2017-10-01

    Our purpose was to evaluate the vertical ground reaction force, impulse, moments and powers of hip, knee and ankle joints, contact time, and jump height when performing a drop jump from different drop heights based on the percentage of a performer's maximum vertical jump height (MVJH). Fifteen male Division III athletes participated voluntarily. Eleven synchronized cameras and two force platforms were used to collect data. One-way repeated-measures analysis of variance tests were used to examine the differences between drop heights. The maximum hip, knee and ankle power absorption during 125%MVJH and 150%MVJH were greater than those during 75%MVJH. The impulse during landing at 100%MVJH, 125%MVJH and 150%MVJH were greater than 75%MVJH. The vertical ground reaction force during 150%MVJH was greater than 50%MVJH, 75%MVJH and 100%MVJH. Drop height below 75%MVJH had the most merits for increasing joint power output while having a lower impact force, impulse and joint power absorption. Drop height of 150%MVJH may not be desirable as a high-intensity stimulus due to the much greater impact force, increasing the risk of injury, without increasing jump height performance. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Interlimb symmetry of dynamic knee joint stiffness and co-contraction is maintained in early stage knee osteoarthritis.

    PubMed

    Collins, A T; Richardson, R T; Higginson, J S

    2014-08-01

    Individuals with knee OA often exhibit greater co-contraction of antagonistic muscle groups surrounding the affected joint which may lead to increases in dynamic joint stiffness. These detrimental changes in the symptomatic limb may also exist in the contralateral limb, thus contributing to its risk of developing knee osteoarthritis. The purpose of this study is to investigate the interlimb symmetry of dynamic knee joint stiffness and muscular co-contraction in knee osteoarthritis. Muscular co-contraction and dynamic knee joint stiffness were assessed in 17 subjects with mild to moderate unilateral medial compartment knee osteoarthritis and 17 healthy control subjects while walking at a controlled speed (1.0m/s). Paired and independent t-tests determined whether significant differences exist between groups (p<0.05). There were no significant differences in dynamic joint stiffness or co-contraction between the OA symptomatic and OA contralateral group (p=0.247, p=0.874, respectively) or between the OA contralateral and healthy group (p=0.635, p=0.078, respectively). There was no significant difference in stiffness between the OA symptomatic and healthy group (p=0.600); however, there was a slight trend toward enhanced co-contraction in the symptomatic knees compared to the healthy group (p=0.051). Subjects with mild to moderate knee osteoarthritis maintain symmetric control strategies during gait. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Estimating patient-specific soft-tissue properties in a TKA knee.

    PubMed

    Ewing, Joseph A; Kaufman, Michelle K; Hutter, Erin E; Granger, Jeffrey F; Beal, Matthew D; Piazza, Stephen J; Siston, Robert A

    2016-03-01

    Surgical technique is one factor that has been identified as critical to success of total knee arthroplasty. Researchers have shown that computer simulations can aid in determining how decisions in the operating room generally affect post-operative outcomes. However, to use simulations to make clinically relevant predictions about knee forces and motions for a specific total knee patient, patient-specific models are needed. This study introduces a methodology for estimating knee soft-tissue properties of an individual total knee patient. A custom surgical navigation system and stability device were used to measure the force-displacement relationship of the knee. Soft-tissue properties were estimated using a parameter optimization that matched simulated tibiofemoral kinematics with experimental tibiofemoral kinematics. Simulations using optimized ligament properties had an average root mean square error of 3.5° across all tests while simulations using generic ligament properties taken from literature had an average root mean square error of 8.4°. Specimens showed large variability among ligament properties regardless of similarities in prosthetic component alignment and measured knee laxity. These results demonstrate the importance of soft-tissue properties in determining knee stability, and suggest that to make clinically relevant predictions of post-operative knee motions and forces using computer simulations, patient-specific soft-tissue properties are needed. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  15. Interlimb symmetry of dynamic knee joint stiffness and co-contraction is maintained in early stage knee osteoarthritis

    PubMed Central

    Collins, A.T.; Richardson, R.T.; Higginson, J.S.

    2014-01-01

    Individuals with knee OA often exhibit greater co-contraction of antagonistic muscle groups surrounding the affected joint which may lead to increases in dynamic joint stiffness. These detrimental changes in the symptomatic limb may also exist in the contralateral limb, thus contributing to its risk of developing knee osteoarthritis. The purpose of this study is to investigate the interlimb symmetry of dynamic knee joint stiffness and muscular co-contraction in knee osteoarthritis. Muscular co-contraction and dynamic knee joint stiffness were assessed in 17 subjects with mild to moderate unilateral medial compartment knee osteoarthritis and 17 healthy control subjects while walking at a controlled speed (1.0 m/s). Paired and independent t-tests determined whether significant differences exist between groups (p < 0.05). There were no significant differences in dynamic joint stiffness or co-contraction between the OA symptomatic and OA contralateral group (p = 0.247, p = 0.874, respectively) or between the OA contralateral and healthy group (p = 0.635, p = 0.078, respectively). There was no significant difference in stiffness between the OA symptomatic and healthy group (p = 0.600); however, there was a slight trend toward enhanced co-contraction in the symptomatic knees compared to the healthy group (p = 0.051). Subjects with mild to moderate knee osteoarthritis maintain symmetric control strategies during gait. PMID:24768278

  16. Evaluation of 3D printed anatomically scalable transfemoral prosthetic knee.

    PubMed

    Ramakrishnan, Tyagi; Schlafly, Millicent; Reed, Kyle B

    2017-07-01

    This case study compares a transfemoral amputee's gait while using the existing Ossur Total Knee 2000 and our novel 3D printed anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee is 3D printed out of a carbon-fiber and nylon composite that has a gear-mesh coupling with a hard-stop weight-actuated locking mechanism aided by a cross-linked four-bar spring mechanism. This design can be scaled using anatomical dimensions of a human femur and tibia to have a unique fit for each user. The transfemoral amputee who was tested is high functioning and walked on the Computer Assisted Rehabilitation Environment (CAREN) at a self-selected pace. The motion capture and force data that was collected showed that there were distinct differences in the gait dynamics. The data was used to perform the Combined Gait Asymmetry Metric (CGAM), where the scores revealed that the overall asymmetry of the gait on the Ossur Total Knee was more asymmetric than the anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee had higher peak knee flexion that caused a large step time asymmetry. This made walking on the anatomically scalable transfemoral prosthetic knee more strenuous due to the compensatory movements in adapting to the different dynamics. This can be overcome by tuning the cross-linked spring mechanism to emulate the dynamics of the subject better. The subject stated that the knee would be good for daily use and has the potential to be adapted as a running knee.

  17. Kinematic alterations of the lower limbs and pelvis during an ascending stairs task are associated with the degree of knee osteoarthritis severity.

    PubMed

    Gonçalves, Glaucia Helena; Selistre, Luiz Fernando Approbato; Petrella, Marina; Mattiello, Stela Márcia

    2017-03-01

    Individuals with knee osteoarthritis (OA) generally demonstrate great difficulty in ascending stairs. The strategies and compensations used by these individuals in stair activities have not been fully established. The purpose of this study was to investigate the joint kinematics of the pelvis, hip, knee and ankle throughout the gait cycle, in the sagittal and frontal planes, in individuals with mild and moderate knee OA, during an ascending stairs task. Thirty-one individuals with knee OA and 19 controls were subjected to clinical and radiographic analysis, divided into three groups: control, mild knee OA, and moderate knee OA. Participants answered a self-reported questionnaire, carried out performance-based tests, and their kinematic data were recorded during an ascending stairs task using an eight-camera Qualisys 3D-Motion analysis system. The individuals with moderate degrees of knee OA demonstrated kinematic alterations in the pelvis, hip, knee, and ankle in the sagittal plane. The individuals with mild degrees of knee OA demonstrated kinematic alterations of the hip in the frontal plane, and kinematic alterations of the ankle in the sagittal plane. The ascending stairs task allowed verification of meaningful information regarding gait strategies used by individuals with mild and moderate knee OA. The strategies of these two groups of individuals are different for this task, although more pronounced in individuals with moderate knee OA. The findings should be taken into account in the development of rehabilitation programs. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. The KineSpring® Knee Implant System: an implantable joint-unloading prosthesis for treatment of medial knee osteoarthritis

    PubMed Central

    Clifford, Anton G; Gabriel, Stefan M; O’Connell, Mary; Lowe, David; Miller, Larry E; Block, Jon E

    2013-01-01

    Symptomatic medial compartment knee osteoarthritis (OA) is the leading cause of musculoskeletal pain and disability in adults. Therapies intended to unload the medial knee compartment have yielded unsatisfactory results due to low patient compliance with conservative treatments and high complication rates with surgical options. There is no widely available joint-unloading treatment for medial knee OA that offers clinically important symptom alleviation, low complication risk, and high patient acceptance. The KineSpring® Knee Implant System (Moximed, Inc, Hayward, CA, USA) is a first-of-its-kind, implantable, extra-articular, extra-capsular prosthesis intended to alleviate knee OA-related symptoms by reducing medial knee compartment loading while overcoming the limitations of traditional joint-unloading therapies. Preclinical and clinical studies have demonstrated excellent prosthesis durability, substantial reductions in medial compartment and total joint loads, and clinically important improvements in OA-related pain and function. The purpose of this report is to describe the KineSpring System, including implant characteristics, principles of operation, indications for use, patient selection criteria, surgical technique, postoperative care, preclinical testing, and clinical experience. The KineSpring System has potential to bridge the gap between ineffective conservative treatments and irreversible surgical interventions for medial compartment knee OA. PMID:23717052

  19. Knee stability before and after total and unicondylar knee replacement: in vivo kinematic evaluation utilizing navigation.

    PubMed

    Casino, Daniela; Martelli, Sandra; Zaffagnini, Stefano; Lopomo, Nicola; Iacono, Francesco; Bignozzi, Simone; Visani, Andrea; Marcacci, Maurilio

    2009-02-01

    Surgical navigation systems are currently used to guide the surgeon in the correct alignment of the implant. The aim of this study was to expand the use of navigation systems by proposing a surgical protocol for intraoperative kinematics evaluations during knee arthroplasty. The protocol was evaluated on 20 patients, half undergoing unicondylar knee arthroplasty (UKA) and half undergoing posterior-substituting, rotating-platform total knee arthroplasty (TKA). The protocol includes a simple acquisition procedure and an original elaboration methodology. Kinematic tests were performed before and after surgery and included varus/valgus stress at 0 and 30 degrees and passive range of motion. Both UKA and TKA improved varus/valgus stability in extension and preserved the total magnitude of screw-home motion during flexion. Moreover, compared to preoperative conditions, values assumed by tibial axial rotation during flexion in TKA knees were more similar to the rotating patterns of UKA knees. The analysis of the anteroposterior displacement of the knee compartments confirmed that the two prostheses did not produce medial pivoting, but achieved a postoperative normal behavior. These results demonstrated that proposed intraoperative kinematics evaluations by a navigation system provided new information on the functional outcome of the reconstruction useful to restore knee kinematics during surgery.

  20. BIOENERGETIC DIFFERENCES DURING WALKING AND RUNNING IN TRANSFEMORAL AMPUTEE RUNNERS USING ARTICULATING AND NON-ARTICULATING KNEE PROSTHESES

    PubMed Central

    Highsmith, M. Jason; Kahle, Jason T.; Miro, Rebecca M.; Mengelkoch, Larry J.

    2016-01-01

    Transfemoral amputation (TFA) patients require considerably more energy to walk and run than non-amputees. The purpose of this study was to examine potential bioenergetic differences (oxygen uptake (VO2), heart rate (HR), and ratings of perceived exertion (RPE)) for TFA patients utilizing a conventional running prosthesis with an articulating knee mechanism versus a running prosthesis with a non-articulating knee joint. Four trained TFA runners (n = 4) were accommodated to and tested with both conditions. VO2 and HR were significantly lower (p ≤ 0.05) in five of eight fixed walking and running speeds for the prosthesis with an articulating knee mechanism. TFA demonstrated a trend for lower RPE at six of eight walking speeds using the prosthesis with the articulated knee condition. A trend was observed for self-selected walking speed, self-selected running speed, and maximal speed to be faster for TFA subjects using the prosthesis with the articulated knee condition. Finally, all four TFA participants subjectively preferred running with the prosthesis with the articulated knee condition. These findings suggest that, for trained TFA runners, a running prosthesis with an articulating knee prosthesis reduces ambulatory energy costs and enhances subjective perceptive measures compared to using a non-articulating knee prosthesis. PMID:28066524

  1. Occupational activity and osteoarthritis of the knee.

    PubMed Central

    Cooper, C; McAlindon, T; Coggon, D; Egger, P; Dieppe, P

    1994-01-01

    OBJECTIVES--To test the hypothesis that specific occupational physical activities are risk factors for knee osteoarthritis (OA). METHODS--A population-based case-control study of knee osteoarthritis was carried out in which 109 men and women with painful, radiographically confirmed knee OA were compared with 218 age and sex matched controls who had not suffered knee pain and had normal radiographs. Information collected included a lifetime occupational history and details of specific workplace physical activities. RESULTS--After adjustment for obesity and Heberden's nodes, the risk of knee OA was significantly elevated in subjects whose main job entailed more than 30 minutes per day squatting (OR 6.9, 95% CI 1.8-26.4) or kneeling (OR 3.4, 95% CI 1.3-9.1), or climbing more than ten flights of stairs per day (OR 2.7, 95% CI 1.2-6.1). The increase in risk associated with kneeling or squatting appeared to be more marked in subjects whose jobs entailed heavy lifting, but the size of the study did not permit precise delineation of any such interaction. CONCLUSIONS--These data suggest that prolonged or repeated knee bending is a risk factor for knee OA, and that risk may be higher in jobs which entail both knee bending and mechanical loading. PMID:8129467

  2. Effect of Age on Cost-Effectiveness of Unicompartmental Knee Arthroplasty Compared with Total Knee Arthroplasty in the U.S.

    PubMed Central

    Ghomrawi, Hassan M.; Eggman, Ashley A.; Pearle, Andrew D.

    2015-01-01

    Background: Trade-offs between upfront benefits and later risk of revision of unicompartmental knee arthroplasty compared with those of total knee arthroplasty are poorly understood. The purpose of our study was to compare the cost-effectiveness of unicompartmental knee arthroplasty with that of total knee arthroplasty across the age spectrum of patients undergoing knee replacement. Methods: Using a Markov decision analytic model, we compared unicompartmental knee arthroplasty with total knee arthroplasty with regard to lifetime costs, quality-adjusted life-years (QALYs), and incremental cost-effectiveness ratios (ICERs) from a societal perspective for patients undergoing surgery at forty-five, fifty-five, sixty-five, seventy-five, or eighty-five years of age. Transition probabilities were estimated from the literature; survival, from the Swedish Knee Arthroplasty Register; and costs, from the literature and the Healthcare Cost and Utilization Project (HCUP) database. Costs and QALYs were discounted at 3.0% annually. We conducted sensitivity analyses to test the robustness of model estimates and threshold analyses. Results: For patients sixty-five years of age and older, unicompartmental knee arthroplasty dominated total knee arthroplasty, with lower lifetime costs and higher QALYs. Unicompartmental knee arthroplasty was no longer cost-effective at a $100,000/QALY threshold when total knee arthroplasty rehabilitation costs were reduced by two-thirds or more for these older patients. Lifetime societal savings from utilizing unicompartmental knee arthroplasty in all older patients (sixty-five or older) in 2015 and 2020 were $56 to $336 million and $84 to $544 million, respectively. In the forty-five and fifty-five-year-old age cohorts, total knee arthroplasty had an ICER of $30,300/QALY and $63,000/QALY, respectively. Unicompartmental knee arthroplasty became cost-effective when its twenty-year revision rate dropped from 27.8% to 25.7% for the forty-five-year age group and from 27.9% to 26.7% for the fifty-five-year age group. Conclusions: Unicompartmental knee arthroplasty is an economically attractive alternative in patients sixty-five years of age or older, and modest improvements in implant survivorship could make it a cost-effective alternative in younger patients. PMID:25740030

  3. 2D AND 3D KINEMATICS DURING LATERAL STEP-DOWN TESTING IN INDIVIDUALS WITH ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION.

    PubMed

    Mostaed, Maria F; Werner, David M; Barrios, Joaquin A

    2018-02-01

    The lateral step-down test is an established clinical evaluation tool to assess quality of movement in patients with knee disorders. However, this test has not been investigated in individuals after anterior cruciate ligament reconstruction (ACLR) in association with quantitative 3D motion analysis. The purpose of this study was to determine the strength of association between visually-assessed quality of movement during the lateral step-down test and 3D lower limb kinematics in patients with history of ACLR. A second purpose was to compare kinematics between subgroups based on the presence or absence of faulty alignments during the task. The final purpose was to compare visually-assessed quality of movement scores between box heights during lateral step-down testing. Twenty subjects at least one year status post-ACLR (18 females, age of 24.5 ± 4.6 years and body mass index of 23.4 ± 2.3 kg/m 2 ) performed the lateral step-down test unilaterally on the surgical limb atop four and six inch boxes. A board-certified orthopedic physical therapist scored overall quality of movement during the lateral step-down test using established criteria during 2D video playback. Lower limb kinematics were simultaneously collected using 3D motion capture. An alpha level of 0.05 was used for all statistical treatments. Overall 2D quality of movement score significantly correlated (r =0.47-0.57) with 3D hip adduction and hip internal rotation across box heights. Across box heights, the presence of faulty pelvic alignment differentiated a subgroup exhibiting less peak knee flexion, and the presence of faulty knee alignment differentiated a subgroup exhibiting greater peak hip adduction. The six inch box elicited worse quality of movement compared to the four inch box. These results suggest that visually-assessed quality of movement is associated with several kinematic variables after ACLR. 2D movement deviations at the pelvis appear to consistently relate to less knee flexion, and 2D deviations at the knee appear to suggest greater hip adduction. Generally, poorer quality of movement was observed for the six inch box height. Clinically, these data suggest that interventions targeting hip abductor and knee extensor strength and neuromuscular control may be useful in the presence of poor quality of movement during lateral step-down testing. 2b.

  4. Does patella position influence ligament balancing in total knee arthroplasty?

    PubMed

    Yoon, Jung-Ro; Oh, Kwang-Jun; Wang, Joon Ho; Yang, Jae-Hyuk

    2015-07-01

    In vivo comparative gap measurements were performed in three different patella positions (reduced, subluxated and everted) using offset-type-force-controlled-spreader-system. Prospectively, 50 knees were operated by total knee arthroplasty using a navigation-assisted gap-balancing technique. The offset-type-force-controlled-spreader-system was used for gap measurements. This commercially available instrument allows controllable tension in patella-reduced position. The mediolateral gaps of knee extension (0°) and flexion (90°) angle were recorded in three different patella positions; reduced, subluxated and everted. Any gap differences of more than 3 mm were considered as a meaningful difference. Correlation between the difference with the demographic data, preoperative radiologic alignment and intraoperative data was analysed. For statistical analysis, ANOVA and Pearson's correlation test were used. The gaps in patella eversion demonstrated smaller gaps both in knee extension and flexion position compared to the gaps of patella reduction position. The amount of decreased gaps was more definite in knee flexion position. Statistically significant difference was observed for the lateral gap of patella eversion compared to gap of patella reduction in knee flexion position (p < 0.05). There were notable cases of variability in knee flexion position. Significant portion of 12 (24 %) knees of patella subluxation and 33 (66 %) knees of patella evertion demonstrated either increased or decreased gaps in knee flexion position compared to the gaps of patella reduction position. The gaps in patella eversion demonstrated smaller gaps both in knee extension and flexion position compared to the gaps of patella reduction position. The amount of decreased gaps was more definite in knee flexion position. Therefore, the intraoperative patellar positioning has influence on the measurement of the joint gap. Keeping the patella in reduced position is important during gap balancing. I.

  5. Lean muscle volume of the thigh has a stronger relationship with muscle power than muscle strength in women with knee osteoarthritis.

    PubMed

    Davison, Michael J; Maly, Monica R; Keir, Peter J; Hapuhennedige, Sandani M; Kron, Amie T; Adachi, Jonathan D; Beattie, Karen A

    2017-01-01

    Thigh lean muscle and intramuscular fat have been implicated in the impairment of physical function observed in people with knee osteoarthritis. We investigated the relationships of quadriceps and hamstrings intramuscular fat fraction and lean muscle volume with muscle power and strength, controlling for neuromuscular activation, and physical performance in women with knee OA. Women (n=20) 55years or older with symptomatic, radiographic knee osteoarthritis underwent a 3.0T magnetic resonance imaging scan of the thigh of their most symptomatic knee. Axial fat-separated images were analyzed using software to quantify intramuscular fat and lean muscle volumes of the quadriceps and hamstrings. To quantify strength and power of the knee extensors and flexors, participants performed maximum voluntary isometric contraction and isotonic knee extensions and flexions, respectively. Electromyography of the quadriceps and hamstrings was measured. Participants also completed five physical performance tests. Quadriceps and hamstrings lean muscle volumes were related to isotonic knee extensor (B=0.624; p=0.017) and flexor (B=1.518; p=0.032) power, but not knee extensor (B=0.001; p=0.615) or flexor (B=0.001; p=0.564) isometric strength. Intramuscular fat fractions were not related to isotonic knee extensor or flexor power, nor isometric strength. No relationships were found between intramuscular fat or lean muscle volume and physical performance. Muscle power may be more sensitive than strength to lean muscle mass in women with knee osteoarthritis. Thigh lean muscle mass, but neither intramuscular nor intermuscular fat, is related to knee extensor and flexor power in women with knee osteoarthritis. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Side Differences of Thigh Muscle Cross-Sectional Areas and Maximal Isometric Muscle Force in Bilateral Knees with the Same Radiographic Disease Stage, but Unilateral Frequent Pain – Data from the Osteoarthritis Initiative

    PubMed Central

    Sattler, Martina; Dannhauer, Torben; Hudelmaier, Martin; Wirth, Wolfgang; Sänger, Alexandra M.; Kwoh, C. Kent; Hunter, David J.; Eckstein, Felix

    2012-01-01

    Objective To determine whether anatomical thigh muscle cross-sectional areas (MCSAs) and strength differ between osteoarthritis (OA) knees with frequent pain compared with contralateral knees without pain, and to examine the correlation between MCSAs and strength in painful versus painless knees. Methods 48 subjects (31 women; 17 men; age 45–78 years) were drawn from 4796 Osteoarthritis Initiative (OAI) participants, in whom both knees displayed the same radiographic stage (KLG2 or 3), one with frequent pain (most days of the month within the past 12 months) and the contralateral one without pain. Axial MR images were used to determine MCSAs of extensors, flexors and adductors at 35% femoral length (distal to proximal) and in two adjacent 5 mm images. Maximal isometric extensor and flexor forces were used as provided from the OAI data base. Results Painful knees showed 5.2% lower extensor MCSAs (p=0.00003; paired t-test), and 7.8% lower maximal extensor muscle forces (p=0.003) than contra-lateral painless knees. There were no significant differences in flexor forces, or flexor and adductor MCSAs (p>0.39). Correlations between force and MCSAs were similar in painful and painless OA knees (0.44

  7. Soft-Tissue Reconstruction of the Complicated Knee Arthroplasty: Principles and Predictors of Salvage.

    PubMed

    Colen, David L; Carney, Martin J; Shubinets, Valeriy; Lanni, Michael A; Liu, Tiffany; Levin, L Scott; Lee, Gwo-Chin; Kovach, Stephen J

    2018-04-01

    Total knee arthroplasty is a common orthopedic procedure in the United States and complications can be devastating. Soft-tissue compromise or joint infection may cause failure of prosthesis requiring knee fusion or amputation. The role of a plastic surgeon in total knee arthroplasty is critical for cases requiring optimization of the soft-tissue envelope. The purpose of this study was to elucidate factors associated with total knee arthroplasty salvage following complications and clarify principles of reconstruction to optimize outcomes. A retrospective review of patients requiring soft-tissue reconstruction performed by the senior author after total knee arthroplasty over 8 years was completed. Logistic regression and Fisher's exact tests determined factors associated with the primary outcome, prosthesis salvage versus knee fusion or amputation. Seventy-three knees in 71 patients required soft-tissue reconstruction (mean follow-up, 1.8 years), with a salvage rate of 61.1 percent, mostly using medial gastrocnemius flaps. Patients referred to our institution with complicated periprosthetic wounds were significantly more likely to lose their knee prosthesis than patients treated only within our system. Patients with multiple prior knee operations before definitive soft-tissue reconstruction had significantly decreased rates of prosthesis salvage and an increased risk of amputation. Knee salvage significantly decreased with positive joint cultures (Gram-negative greater than Gram-positive organisms) and particularly at the time of definitive reconstruction, which also trended toward an increased risk of amputation. In revision total knee arthroplasty, prompt soft-tissue reconstruction improves the likelihood of success, and protracted surgical courses and contamination increase failure and amputations. The authors show a benefit to involving plastic surgeons early in the course of total knee arthroplasty complications to optimize genicular soft tissues. Therapeutic, III.

  8. The dynamics of the pain system is intact in patients with knee osteoarthritis: An exploratory experimental study.

    PubMed

    Jørgensen, Tanja Schjødt; Henriksen, Marius; Rosager, Sara; Klokker, Louise; Ellegaard, Karen; Danneskiold-Samsøe, Bente; Bliddal, Henning; Graven-Nielsen, Thomas

    2017-12-29

    Background and aims Despite the high prevalence of knee osteoarthritis (OA) it remains one of the most frequent knee disorders without a cure. Pain and disability are prominent clinical features of knee OA. Knee OA pain is typically localized but can also be referred to the thigh or lower leg. Widespread hyperalgesia has been found in knee OA patients. In addition, patients with hyperalgesia in the OA knee joint show increased pain summation scores upon repetitive stimulation of the OA knee suggesting the involvement of facilitated central mechanisms in knee OA. The dynamics of the pain system (i.e., the adaptive responses to pain) has been widely studied, but mainly from experiments on healthy subjects, whereas less is known about the dynamics of the pain system in chronic pain patients, where the pain system has been activated for a long time. The aim of this study was to assess the dynamics of the nociceptive system quantitatively in knee osteoarthritis (OA) patients before and after induction of experimental knee pain. Methods Ten knee osteoarthritis (OA) patients participated in this randomized crossover trial. Each subject was tested on two days separated by 1 week. The most affected knee was exposed to experimental pain or control, in a randomized sequence, by injection of hypertonic saline into the infrapatellar fat pad and a control injection of isotonic saline. Pain areas were assessed by drawings on anatomical maps. Pressure pain thresholds (PPT) at the knee, thigh, lower leg, and arm were assessed before, during, and after the experimental pain and control conditions. Likewise, temporal summation of pressure pain on the knee, thigh and lower leg muscles was assessed. Results Experimental knee pain decreased the PPTs at the knee (P <0.01) and facilitated the temporal summation on the knee and adjacent muscles (P < 0.05). No significant difference was found at the control site (the contralateral arm) (P =0.77). Further, the experimental knee pain revealed overall higher VAS scores (facilitated temporal summation of pain) at the knee (P < 0.003) and adjacent muscles (P < 0.0001) compared with the control condition. The experimental knee pain areas were larger compared with the OA knee pain areas before the injection. Conclusions Acute experimental knee pain induced in patients with knee OA caused hyperalgesia and facilitated temporal summation of pain at the knee and surrounding muscles, illustrating that the pain system in individuals with knee OA can be affected even after many years of nociceptive input. This study indicates that the adaptability in the pain system is intact in patients with knee OA, which opens for opportunities to prevent development of centralized pain syndromes.

  9. Segmentation of knee cartilage by using a hierarchical active shape model based on multi-resolution transforms in magnetic resonance images

    NASA Astrophysics Data System (ADS)

    León, Madeleine; Escalante-Ramirez, Boris

    2013-11-01

    Knee osteoarthritis (OA) is characterized by the morphological degeneration of cartilage. Efficient segmentation of cartilage is important for cartilage damage diagnosis and to support therapeutic responses. We present a method for knee cartilage segmentation in magnetic resonance images (MRI). Our method incorporates the Hermite Transform to obtain a hierarchical decomposition of contours which describe knee cartilage shapes. Then, we compute a statistical model of the contour of interest from a set of training images. Thereby, our Hierarchical Active Shape Model (HASM) captures a large range of shape variability even from a small group of training samples, improving segmentation accuracy. The method was trained with a training set of 16- MRI of knee and tested with leave-one-out method.

  10. Does the addition of hip strengthening exercises improve outcomes following total knee arthroplasty? A study protocol for a randomized trial.

    PubMed

    Schache, Margaret B; McClelland, Jodie A; Webster, Kate E

    2016-06-13

    Total knee arthroplasty (TKA) is effective in reducing pain and improving function for end-stage knee osteoarthritis. However, muscle weakness and functional limitations persist despite assistance from post-operative rehabilitation programs that traditionally focus on quadriceps strengthening and range of movement exercises. Hip abductor muscle weakness is evident in knee osteoarthritis and hip muscle strengthening reduces knee pain in this group. Following TKA, people with weak hip abductor strength perform more poorly on measures of physical function. However, very little is known of the effectiveness of including hip abductor strengthening exercises in post-operative rehabilitation. The aim of this trial is to compare the effects of targeted hip abductor strengthening to those of traditional care in a TKA rehabilitation program on muscle strength, patient reported outcomes and functional performance measures. This protocol describes a single-blinded randomized controlled trial, where 104 participants referred for inpatient rehabilitation following TKA will be recruited. Participants will be randomized using computer-generated numbers to one of two groups: usual care or usual care with additional hip strengthening exercises. Participants will attend physiotherapy daily during their inpatient length of stay, and will then attend between six and eight physiotherapy sessions as an outpatient. Primary outcomes are isometric hip abductor strength and the Knee Injury and Osteoarthritis Outcome Score (KOOS). Secondary outcomes are stair climb test, 6 min walk test, timed up and go, 40 m fast-paced walk test, 30 second chair stand test, isometric quadriceps strength, Lower Extremity Functional Scale (LEFS) and SF-12. Outcome measures will be recorded at baseline (admission to inpatient rehabilitation), and then 3 weeks, 6 weeks and 6 months post admission to rehabilitation. The findings of this study will determine whether the addition of targeted hip strengthening to usual care rehabilitation improves physical performance and patient reported outcomes following TKA when compared to usual care rehabilitation. This will then determine whether targeted hip strengthening exercises should be included in traditional rehabilitation programs to improve the outcomes following total knee arthroplasty. The trial protocol was registered with the Australian Clinical Trial Registry ( ACTRN12615000863538 ) on 18 August 2015.

  11. Paradoxical phenomena of the McMurray test. An arthroscopic investigation.

    PubMed

    Kim, S J; Min, B H; Han, D Y

    1996-01-01

    We evaluated 200 patients who had a positive McMurray test and found atypical McMurray test results in 24 patients (12%). These patients revealed pain or clicking or both either in the medial compartment of the knee when the leg was internally rotated or in the lateral compartment of the knee when the leg was externally rotated. The authors analyzed these paradoxical findings at arthroscopic examination to identify the relationship between the type of meniscal tear and the direction of leg rotation that elicited the catching and displacement of the torn meniscal portion during the McMurray test. Contrary to conventional McMurray test findings, three different types of meniscal tears were found on the side of the knee where pain or a clicking sound occurred. The three types were 1) anteriorly based posterior oblique tears with anterior displacement of the meniscus, 2) bucket-handle tears in the posterior half of the menisci, and 3) peripheral detachment of discoid menisci in the posterior half of the torn portions.

  12. Impact of synovial fluid flow on temperature regulation in knee cartilage.

    PubMed

    Moghadam, Mohamadreza Nassajian; Abdel-Sayed, Philippe; Camine, Valérie Malfroy; Pioletti, Dominique P

    2015-01-21

    Several studies have reported an increase of temperature in cartilage submitted to cyclic sinusoidal loading. The temperature increase is in part due to the viscous behavior of this tissue, which partially dissipates the input mechanical energy into heat. While the synovial fluid flow within the intra-articular gap and inside the porous cartilage is supposed to play an important role in the regulation of the cartilage temperature, no specific study has evaluated this aspect. In the present numerical study, a poroelastic model of the knee cartilage is developed to evaluate first the temperature increase in the cartilage due to dissipation and second the impact of the synovial fluid flow in the cartilage heat transfer phenomenon. Our results showed that, the local temperature is effectively increased in knee cartilage due to its viscous behavior. The synovial fluid flow cannot significantly preventing this phenomenon. We explain this result by the low permeability of cartilage and the moderate fluid exchange at the surface of cartilage under deformation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Influence of a Full-Body Compression Suit on Trunk Positioning and Knee Joint Mechanics During Lateral Movements.

    PubMed

    Mornieux, Guillaume; Weltin, Elmar; Pauls, Monika; Rott, Franz; Gollhofer, Albert

    2017-08-01

    Trunk positioning has been shown to be associated with knee joint loading during athletic tasks, especially changes of direction. The purpose of the present study was to test whether a full-body compression suit (FBCS) would improve trunk positioning and knee joint control during lateral movements. Twelve female athletes performed lateral reactive jumps (LRJ) and unanticipated cuttings with and without the customized FBCS, while 3D kinematics and kinetics were measured. FBCS did not influence trunk positioning during LRJ and led to increased trunk lateral lean during cuttings (P < .001). However, while wearing FBCS, knee joint abduction and internal rotation angles were reduced during LRJ (P < .001 and P = .013, respectively), whereas knee joint moments were comparable during cuttings. FBCS cannot support the trunk segment during unanticipated dynamic movements. But, increased trunk lateral lean during cutting maneuvers was not high enough to elicit increased knee joint moments. On the contrary, knee joint abduction and internal rotation were reduced during LRJ, speaking for a better knee joint alignment with FBCS. Athletes seeking to improve trunk positioning may not benefit from a FBCS.

  14. Prediction of Knee Joint Contact Forces From External Measures Using Principal Component Prediction and Reconstruction.

    PubMed

    Saliba, Christopher M; Clouthier, Allison L; Brandon, Scott C E; Rainbow, Michael J; Deluzio, Kevin J

    2018-05-29

    Abnormal loading of the knee joint contributes to the pathogenesis of knee osteoarthritis. Gait retraining is a non-invasive intervention that aims to reduce knee loads by providing audible, visual, or haptic feedback of gait parameters. The computational expense of joint contact force prediction has limited real-time feedback to surrogate measures of the contact force, such as the knee adduction moment. We developed a method to predict knee joint contact forces using motion analysis and a statistical regression model that can be implemented in near real-time. Gait waveform variables were deconstructed using principal component analysis and a linear regression was used to predict the principal component scores of the contact force waveforms. Knee joint contact force waveforms were reconstructed using the predicted scores. We tested our method using a heterogenous population of asymptomatic controls and subjects with knee osteoarthritis. The reconstructed contact force waveforms had mean (SD) RMS differences of 0.17 (0.05) bodyweight compared to the contact forces predicted by a musculoskeletal model. Our method successfully predicted subject-specific shape features of contact force waveforms and is a potentially powerful tool in biofeedback and clinical gait analysis.

  15. Modeling impairment: using the disablement process as a framework to evaluate determinants of hip and knee flexion.

    PubMed

    Lichtenstein, M J; Dhanda, R; Cornell, J E; Escalante, A; Hazuda, H P

    2000-06-01

    Elders often present to health care providers with multiple inter-related conditions that determine an individual's ability to function. The disablement process provides a generalized sociomedical framework for investigating the complex pathways from chronic disease to disability. At each stage of the main pathway, associations may exist among primary physical factors and modifying variables that ultimately have downstream effects on the progression toward disability. The purpose of the present analysis is to examine the inter-relationships between a cohesive set of variables primarily at the level of impairment that may affect hip and knee flexion range of motion (ROM). The San Antonio Longitudinal Study of Aging enrolled 833 community dwelling Mexican (MA) and European American (EA) elders aged 64-78 years between 1992 and 1996. Of these, 647 had complete data from both a home-based and performance-based battery of assessments for these analyses. Concerning impairments, hip ROM was measured using an inclinometer, and knee ROM using a goniometer. Pain location and intensity were assessed using the McGill Pain Questionnaire. Peripheral vascular disease was assessed using doppler brachial and ankle systolic blood pressures. Ankle and knee reflexes, and vibratory sensation were assessed by a standardized neurological examination. As to diseases, diabetes was assessed using a combination of blood glucose levels and self-report, and arthritis by self-report. Concerning modifying variables, height and weight were directly measured and used to calculate BMI. Activity level was assessed with the Minnesota Leisure Time Questionnaire. Analgesic use was assessed by direct observation of medications taken within the past two weeks. We used structural equation modeling to test associations between the variables that were specified a priori. These analyses demonstrate the central role of BMI as a determinant of hip and knee flexion ROM. For an increase in level of BMI, the coefficients [SEM] for changes in levels of hip and knee ROM were -0.38 [0.05] and -0.26 [0.05], respectively. A higher BMI resulted in lower hip and knee ROM. BMI was also directly associated with prevalent diabetes (0.10 [0.05]) and arthritis (0.17 [0.05]). However, after adjustment for BMI, diabetes and arthritis did not have direct independent associations with either hip or knee ROM. BMI was also indirectly associated with knee, but not hip, ROM through paths including lower-leg pain, pain intensity, and neurosensory impairments. Diabetes had an indirect association with hip, but not knee ROM, through a path including peripheral vascular disease. In conclusion, BMI is a primary direct determinant of hip and knee ROM. The paths by which diabetes and arthritis lead to physical disability may be mediated, in part, at the level of impairment by BMI's association with joint range of motion. Interventions designed to decrease the impact of diabetes and arthritis on disability should track changes in BMI and joint ROM to measure the paths that account for the intervention's success. The observed associations suggest that interventions targeted to decrease BMI itself may lead to improved function in part through improved joint ROM.

  16. Lyme Disease Presenting as a Spontaneous Knee Effusion.

    PubMed

    Matzkin, Elizabeth; Suslavich, Kaytelin; Curry, Emily J

    2015-11-01

    Musculoskeletal complaints, which are frequently associated with Lyme disease, often prompt patients to see a physician. In particular, transient episodes of spontaneous knee effusion are common early in the progression of Lyme disease, and, if left untreated, 60% of patients diagnosed with the disease develop Lyme arthritis. This disease is easily treated with antibiotics; therefore, inclusion of Lyme disease in the differential diagnosis as a potential cause of a spontaneous knee effusion can prevent the development of more severe symptoms associated with the disease. However, the time required to receive test results and the inconsistencies between serum and synovial tests can complicate diagnosis of the disease. Copyright 2015 by the American Academy of Orthopaedic Surgeons.

  17. Posteromedial Meniscocapsular Lesions Increase Tibiofemoral Joint Laxity With Anterior Cruciate Ligament Deficiency, and Their Repair Reduces Laxity.

    PubMed

    Stephen, Joanna M; Halewood, Camilla; Kittl, Christoph; Bollen, Steve R; Williams, Andy; Amis, Andrew A

    2016-02-01

    Injury to the posteromedial meniscocapsular junction has been identified after anterior cruciate ligament (ACL) rupture; however, there is a lack of objective evidence investigating how this affects knee kinematics or whether increased laxity can be restored by repair. Such injury is often overlooked at surgery, with possible compromise to results. (1) Sectioning the posteromedial meniscocapsular junction in an ACL-deficient knee will result in increased anterior tibial translation and rotation. (2) Isolated ACL reconstruction in the presence of a posteromedial meniscocapsular junction lesion will not restore intact knee laxity. (3) Repair of the posteromedial capsule at the time of ACL reconstruction will reduce tibial translation and rotation to normal. (4) These changes will be clinically detectable. Controlled laboratory study. Nine cadaveric knees were mounted in a test rig where knee kinematics were recorded from 0° to 100° of flexion by use of an optical tracking system. Measurements were recorded with the following loads: 90-N anterior-posterior tibial forces, 5-N·m internal-external tibial rotation torques, and combined 90-N anterior force and 5-N·m external rotation torque. Manual Rolimeter readings of anterior translation were taken at 30° and 90°. The knees were tested in the following conditions: intact, ACL deficient, ACL deficient and posteromedial meniscocapsular junction sectioned, ACL deficient and posteromedial meniscocapsular junction repaired, ACL patellar tendon reconstruction with posteromedial meniscocapsular junction repair, and ACL reconstructed and capsular lesion re-created. Statistical analysis used repeated-measures analysis of variance and post hoc paired t tests with Bonferroni correction. Tibial anterior translation and external rotation were both significantly increased compared with the ACL-deficient knee after posterior meniscocapsular sectioning (P < .05). These parameters were restored after ACL reconstruction and meniscocapsular lesion repair (P > .05). Anterior and external rotational laxities were significantly increased after sectioning of the posteromedial meniscocapsular junction in an ACL-deficient knee. These were not restored after ACL reconstruction alone but were restored with ACL reconstruction combined with posterior meniscocapsular repair. Tibial anterior translation changes were clinically detectable by use of the Rolimeter. This study suggests that unrepaired posteromedial meniscocapsular lesions will allow abnormal meniscal and tibiofemoral laxity to persist postoperatively, predisposing the knee to meniscal and articular damage. © 2015 The Author(s).

  18. Return to knee-strenuous sport after anterior cruciate ligament reconstruction: a report from a rehabilitation outcome registry of patient characteristics.

    PubMed

    Hamrin Senorski, Eric; Samuelsson, Kristian; Thomeé, Christoffer; Beischer, Susanne; Karlsson, Jón; Thomeé, Roland

    2017-05-01

    To characterise patients who returned to knee-strenuous sports after an anterior cruciate ligament (ACL) reconstruction. Data from isotonic tests of muscle function and patient-reported outcome measures, Tegner activity scale (Tegner and Lysholm in Clin Orthop Relat Res 198:43-49, 1985), physical activity scale, knee injury and osteoarthritis scale and knee self-efficacy scale were extracted from a registry. The 157 included patients, 15-30 years of age, had undergone primary ACL reconstruction and were all involved in knee-strenuous sports, i.e. pre-injury Tegner of 6 or higher. Return to sport was studied in two different ways: return to pre-injury Tegner and return to knee-strenuous sport (Tegner 6). Fifty-two patients (33 %), who returned to pre-injury Tegner, 10 months after surgery, were characterised by better subjective knee function measured with the knee injury and osteoarthritis outcome score (p < 0.05), compared with patients who did not. These patients also had higher perceived self-efficacy of knee function (p < 0.01), measured with knee self-efficacy scale. Eighty-four patients (54 %) who returned to knee-strenuous sports, i.e. Tegner 6 or higher, were characterised by higher goals for physical activity (p < 0.01) and higher self-efficacy of future knee function (p < 0.05). Strength measurements showed that women who returned to sports were stronger in leg extension than women who did not. No differences were found in Limb Symmetry Index for knee strength or jumping ability. Patients who returned to sports after ACL reconstruction had better subjective knee function and higher self-efficacy of knee function. Results highlight that further emphasis should be placed at psychological factors during rehabilitation of patients after ACLR. II.

  19. The Analysis of Risk Factors in No Thumb Test in Total Knee Arthroplasty

    PubMed Central

    Kim, Jee Hyoung; Ko, Dong Oh; Yoo, Chang Wook; Chun, Tae Hwan; Lee, Jung Soo

    2011-01-01

    Background We would like to analyze the risk factors of no thumb test among knee alignment tests during total knee arthroplasty surgery. Methods The 156 cases of total knee arthroplasty by an operator from October 2009 to April 2010 were analyzed according to preoperative indicators including body weight, height, degree of varus deformity, and patella subluxation and surgical indicators such as pre-osteotomy patella thickness, degree of patella degeneration, no thumb test which was evaluated after medial prepatella incision and before bone resection (1st test), no thumb test which was evaluated with corrective valgus stress (2nd test, J test), and the kind of prosthesis. We comparatively analyzed indicators affecting no thumb test (3rd test). Results There was no relation between age, sex, and body weight and no thumb test (3rd test). Patellar sulcus angle (p = 0.795), patellar congruence angle (p = 0.276) and preoperative mechanical axis showed no relationship. The 1st no thumb test (p = 0.007) and 2nd test (p = 0.002) showed significant relation with the 3rd no thumb test. Among surgical indicators, pre-osteotomy patella thickness (p = 0.275) and degeneration of patella (p = 0.320) were not relevant but post-osteotomy patellar thickness (p = 0.002) was relevant to no thumb test (3rd test). According to prosthesis, there was no significance with Nexgen (p = 0.575). However, there was significant correlation between Scorpio (p = 0.011), Vanguard (p = 0.049) and no thumb test (3rd test). Especially, Scorpio had a tendency to dislocate the patella, but Vanguard to stabilize the patella. Conclusions No thumb test (3rd test) is correlated positively with 1st test, 2nd test, and post-osteotomy patella thickness. Therefore, the more patella osteotomy and the prosthesis with high affinity to patellofemoral alignment would be required for correct patella alignment. PMID:22162789

  20. Is Knee Separation During a Drop Jump Associated With Lower Extremity Injury in Adolescent Female Soccer Players?

    PubMed

    O'Kane, John W; Tencer, Allan; Neradilek, Moni; Polissar, Nayak; Sabado, Lori; Schiff, Melissa A

    2016-02-01

    Knee injuries are common in older adolescent and adult female soccer players, and abnormal valgus knee appearance characterized by low normalized knee separation (NKS) is a proposed injury risk factor. What constitutes normal NKS in younger adolescents and whether low NKS is an injury risk factor are unknown. To determine the normal range of NKS using a drop-jump test in female perimenarchal youth soccer players and whether low NKS contributes to lower extremity injuries or knee injuries. Cohort study; Level of evidence, 2. From 2008 to 2012, a total of 351 female elite youth soccer players (age range, 11-14 years) were followed for 1 season, with complete follow-up on 92.3% of players. Baseline drop-jump testing was performed preseason. Lower extremity injuries during the season were identified using a validated, Internet-based injury surveillance system with weekly email reporting. Normalized knee separation at prelanding, landing, and takeoff was categorized 2 ways: as ≤10th percentile (most extreme valgus appearance) compared with >10th percentile and as a continuous measure of 1 SD. Poisson regression modeling with adjustment for clustering by team estimated the relative risk (RR) and 95% confidence interval (CI) of the association between the NKS and the risk of lower extremity and knee injury, stratified by menarche. Of the study participants, 134 players experienced 173 lower extremity injuries, with 43 (24.9%) knee injuries. For postmenarchal players (n = 210), those with NKS ≤10th percentile were at 92% increased risk of lower extremity injury (RR, 1.92; 95% CI, 1.17-3.15) and a 3.62-fold increased risk of knee injury (RR, 3.62; 95% CI, 1.18-11.09) compared with NKS >10th percentile at prelanding and landing, respectively. Among postmenarchal players, there was an 80% increased risk of knee injury (RR, 1.80; 95% CI, 1.01-3.23) with a decrease of 1 SD in landing NKS and a 66% increased risk of knee injury (RR, 1.66; 95% CI, 1.04-2.64) with a decrease of 1 SD in takeoff NKS. Among premenarchal players (n = 141), there was no statistically significant association between the NKS at prelanding, landing, and takeoff and the risk of lower extremity or knee injury. Low NKS was associated with increased risk of lower extremity and knee injury only among postmenarchal players. © 2015 The Author(s).

Top