Sample records for knee joint loading

  1. The relationship between knee joint loading rate during walking and degenerative changes on magnetic resonance imaging.

    PubMed

    Morgenroth, David C; Medverd, Jonathan R; Seyedali, Mahyo; Czerniecki, Joseph M

    2014-06-01

    While animal study and cadaveric study have demonstrated an association between knee joint loading rate and joint degeneration, the relationship between knee joint loading rate during walking and osteoarthritis has not yet been sufficiently studied in humans. Twenty-eight participants (14 transfemoral amputees and 14 age and body mass matched controls) underwent knee MRI with subsequent assessment using the semiquantitative Whole-Organ Magnetic Resonance Image Score. Each subject also underwent gait analysis in order to determine knee adduction moment loading rate, peak, and impulse and an exploratory measure, knee adduction moment rate∗magnitude. Significant correlations were found between medial tibiofemoral joint degeneration and knee adduction moment peak (slope=0.42 [SE 0.20]; P=.037), loading rate (slope=12.3 [SE 3.2]; P=.0004), and rate∗magnitude (slope=437 [SE 100]; P<.0001). These relationships continued to be significant after adjusting for body mass or subject type. The relationship between medial knee semiquantitative MRI score and knee adduction moment loading rate and rate∗magnitude continued to be significant even after adjusting for peak moment (P<.0001), however, the relationship between medial knee semiquantitative MRI score and peak moment was no longer significant after adjusting for either loading rate or rate∗magnitude (P>.2 in both cases). This study suggests an independent relationship between knee adduction moment loading rate and medial tibiofemoral joint degeneration. Our results support the hypothesis that rate of loading, represented by the knee adduction moment loading rate, is strongly associated with medial tibiofemoral joint degeneration independent of knee adduction moment peak and impulse. Published by Elsevier Ltd.

  2. Are the Kinematics of the Knee Joint Altered during the Loading Response Phase of Gait in Individuals with Concurrent Knee Osteoarthritis and Complaints of Joint Instability? A Dynamic Stereo X-ray Study

    PubMed Central

    Farrokhi, Shawn; Tashman, Scott; Gil, Alexandra B.; Klatt, Brian A.; Fitzgerald, G. Kelley

    2011-01-01

    Background Joint instability has been suggested as a risk factor for knee osteoarthritis and a cause of significant functional declines in those with symptomatic disease. However, the relationship between altered knee joint mechanics and self-reports of instability in individuals with knee osteoarthritis remains unclear. Methods Fourteen subjects with knee osteoarthritis and complaints of joint instability and 12 control volunteers with no history of knee disease were recruited for this study. Dynamic stereo X-ray technology was used to assess the three-dimensional kinematics of the knee joint during the loading response phase of gait. Findings Individuals with concurrent knee osteoarthritis and joint instability demonstrated significantly reduced flexion and internal/external rotation knee motion excursions during the loading response phase of gait (P < 0.01), while the total abduction/adduction range of motion was increased (P < 0.05). In addition, the coronal and transverse plane alignment of the knee joint at initial contact was significantly different (P < 0.05) for individuals with concurrent knee osteoarthritis and joint instability. However, the anteroposterior and mediolateral tibiofemoral joint positions at initial contact and the corresponding total joint translations were similar between groups during the loading phase of gait. Interpretations The rotational patterns of tibiofemoral joint motion and joint alignments reported for individuals with concurrent knee osteoarthritis and joint instability are consistent with those previously established for individuals with knee osteoarthritis. Furthermore, the findings of similar translatory tibiofemoral motion between groups suggest that self-reports of episodic joint instability in individuals with knee osteoarthritis may not necessarily be associated with adaptive alterations in joint arthrokinematics. PMID:22071429

  3. Are the kinematics of the knee joint altered during the loading response phase of gait in individuals with concurrent knee osteoarthritis and complaints of joint instability? A dynamic stereo X-ray study.

    PubMed

    Farrokhi, Shawn; Tashman, Scott; Gil, Alexandra B; Klatt, Brian A; Fitzgerald, G Kelley

    2012-05-01

    Joint instability has been suggested as a risk factor for knee osteoarthritis and a cause of significant functional decline in those with symptomatic disease. However, the relationship between altered knee joint mechanics and self-reports of instability in individuals with knee osteoarthritis remains unclear. Fourteen subjects with knee osteoarthritis and complaints of joint instability and 12 control volunteers with no history of knee disease were recruited for this study. Dynamic stereo X-ray technology was used to assess the three-dimensional kinematics of the knee joint during the loading response phase of gait. Individuals with concurrent knee osteoarthritis and joint instability demonstrated significantly reduced flexion and internal/external rotation knee motion excursions during the loading response phase of gait (P<0.01), while the total abduction/adduction range of motion was increased (P<0.05). In addition, the coronal and transverse plane alignment of the knee joint at initial contact was significantly different (P<0.05) for individuals with concurrent knee osteoarthritis and joint instability. However, the anteroposterior and mediolateral tibiofemoral joint positions at initial contact and the corresponding total joint translations were similar between groups during the loading phase of gait. The rotational patterns of tibiofemoral joint motion and joint alignments reported for individuals with concurrent knee osteoarthritis and joint instability are consistent with those previously established for individuals with knee osteoarthritis. Furthermore, the findings of similar translatory tibiofemoral motion between groups suggest that self-reports of episodic joint instability in individuals with knee osteoarthritis may not necessarily be associated with adaptive alterations in joint arthrokinematics. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Relative Intensity Influences the Degree of Correspondence of Jump Squats and Push Jerks to Countermovement Jumps.

    PubMed

    Cushion, Emily J; Goodwin, Jon E; Cleather, Daniel J

    2016-05-01

    The aim of this study was to determine the mechanical similarity between push jerk (PJ) and jump squat (JS) to countermovement jump (CMJ) and further understand the effect increasing external load may have on this relationship. Eight physically trained men (age 22 ± 3; height 176 ± 7 kg; weight 83 ± 8 kg) performed an unloaded CMJ followed by JS under a range of loads (10, 25, 35, and 50% 1RM back squat) and PJ (30, 50, 65, and 75% 1RM push jerk). A portable force platform and high-speed camera both collecting at 250 Hz were used to establish joint moments and impulse during the propulsive phase of the movements. A standard inverse dynamics model was used to determine joint moment and impulse at the hip, knee, and ankle. Significant correlations (p ≤ 0.05) were shown between CMJ knee joint moment and JS knee joint moment at 25% load and PJ knee joint moment at 30 and 50% load. Significant correlations were also observed between CMJ knee joint impulse and JS knee joint impulse at 10% load and PJ knee joint moment at 30 and 65% load. Significant correlation was also observed between CMJ hip joint impulse and PJ hip joint impulse at 30% load. No significant joint × load interaction was shown as load increased for either PJ or JS. Results from the study suggest partial correspondence between PJ and JS to CMJ, where a greater mechanical similarity was observed between the PJ and CMJ. This interaction is load and joint dependent where lower relative loads showed greatest mechanical similarity. Therefore using lower relative loads when programming may provide a greater transfer of training effect.

  5. Contribution of tibiofemoral joint contact to net loads at the knee in gait.

    PubMed

    Walter, Jonathan P; Korkmaz, Nuray; Fregly, Benjamin J; Pandy, Marcus G

    2015-07-01

    Inverse dynamics analysis is commonly used to estimate the net loads at a joint during human motion. Most lower-limb models of movement represent the knee as a simple hinge joint when calculating muscle forces. This approach is limited because it neglects the contributions from tibiofemoral joint contact forces and may therefore lead to errors in estimated muscle forces. The aim of this study was to quantify the contributions of tibiofemoral joint contact loads to the net knee loads calculated from inverse dynamics for multiple subjects and multiple gait patterns. Tibiofemoral joint contact loads were measured in four subjects with instrumented implants as each subject walked at their preferred speed (normal gait) and performed prescribed gait modifications designed to treat medial knee osteoarthritis. Tibiofemoral contact loads contributed substantially to the net knee extension and knee adduction moments in normal gait with mean values of 16% and 54%, respectively. These findings suggest that knee-contact kinematics and loads should be included in lower-limb models of movement for more accurate determination of muscle forces. The results of this study may be used to guide the development of more realistic lower-limb models that account for the effects of tibiofemoral joint contact at the knee. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  6. Relationship between leg extensor muscle strength and knee joint loading during gait before and after total knee arthroplasty.

    PubMed

    Vahtrik, Doris; Gapeyeva, Helena; Ereline, Jaan; Pääsuke, Mati

    2014-01-01

    The aim of the present study was to evaluate an isometric maximal voluntary contraction (MVC) force of the leg extensor muscles and its relationship with knee joint loading during gait prior and after total knee arthroplasty (TKA). Custom-made dynamometer was used to assess an isometric MVC force of the leg extensor muscles and 3-D motion analysis system was used to evaluate the knee joint loading during gait in 13 female patients (aged 49-68 years) with knee osteoarthritis. Patients were evaluated one day before, and three and six months following TKA in the operated and non-operated leg. Six months after TKA, MVC force of the leg extensor muscles for the operated leg did not differ significantly as compared to the preoperative level, whereas it remained significantly lower for the non-operated leg and controls. The knee flexion moment and the knee joint power during mid stance of gait was improved six months after TKA, remaining significantly lowered compared with controls. Negative moderate correlation between leg extensor muscles strength and knee joint loading for the operated leg during mid stance was noted three months after TKA. The correlation analysis indicates that due to weak leg extensor muscles, an excessive load is applied to knee joint during mid stance of gait in patients, whereas in healthy subjects stronger knee-surrounding muscles provide stronger knee joint loading during gait. III (correlational study). Copyright © 2013 Elsevier B.V. All rights reserved.

  7. The effect on knee-joint load of instruction in analgesic use compared with neuromuscular exercise in patients with knee osteoarthritis: study protocol for a randomized, single-blind, controlled trial (the EXERPHARMA trial).

    PubMed

    Clausen, Brian; Holsgaard-Larsen, Anders; Søndergaard, Jens; Christensen, Robin; Andriacchi, Thomas P; Roos, Ewa M

    2014-11-15

    Knee osteoarthritis (OA) is a mechanically driven disease, and it is suggested that medial tibiofemoral knee-joint load increases with pharmacologic pain relief, indicating that pharmacologic pain relief may be positively associated with disease progression. Treatment modalities that can both relieve pain and reduce knee-joint load would be preferable. The knee-joint load is influenced by functional alignment of the trunk, pelvis, and lower-limb segments with respect to the knee, as well as the ground-reaction force generated during movement. Neuromuscular exercise can influence knee load and decrease knee pain. It includes exercises to improve balance, muscle activation, functional alignment, and functional knee stability. The primary objective of this randomized controlled trial (RCT) is to investigate the efficacy of a NEuroMuscular EXercise (NEMEX) therapy program, compared with optimized analgesics and antiinflammatory drug use, on the measures of knee-joint load in people with mild to moderate medial tibiofemoral knee osteoarthritis. One hundred men and women with mild to moderate medial knee osteoarthritis will be recruited from general medical practices and randomly allocated (1:1) to one of two 8-week treatments, either (a) NEMEX therapy twice a week or (b) information on the recommended use of analgesics and antiinflammatory drugs (acetaminophen and oral NSAIDs) via a pamphlet and video materials. The primary outcome is change in knee load during walking (the Knee Index, a composite score of the first external peak total reaction moment on the knee joint from all three planes based on 3D movement analysis) after 8 weeks of intervention. Secondary outcomes include changes in the external peak knee-adduction moment and impulse and functional performance measures, in addition to changes in self-reported pain, function, health status, and quality of life. These findings will help determine whether 8 weeks of neuromuscular exercise is superior to optimized use of analgesics and antiinflammatory drugs regarding knee-joint load, pain and physical function in people with mild to moderate knee osteoarthritis. ClinicalTrials.gov Identifier: NCT01638962 (July 3, 2012).

  8. Is increased joint loading detrimental to obese patients with knee osteoarthritis? A secondary data analysis from a randomized trial.

    PubMed

    Henriksen, M; Hunter, D J; Dam, E B; Messier, S P; Andriacchi, T P; Lohmander, L S; Aaboe, J; Boesen, M; Gudbergsen, H; Bliddal, H; Christensen, R

    2013-12-01

    To investigate whether increased knee joint loading due to improved ambulatory function and walking speed following weight loss achieved over 16 weeks accelerates symptomatic and structural disease progression over a subsequent 1 year weight maintenance period in an obese population with knee osteoarthritis (OA). Data from a prospective study of weight loss in obese patients with knee OA (the CARtilage in obese knee OsteoarThritis (CAROT) study) were used to determine changes in knee joint compressive loadings (model estimated) during walking after a successful 16 week weight loss intervention. The participants were divided into 'Unloaders' (participants that reduced joint loads) and 'Loaders' (participants that increased joint loads). The primary symptomatic outcome was changes in knee symptoms, measured with the Knee injury and Osteoarthritis Outcome Score (KOOS) questionnaire, during a subsequent 52 weeks weight maintenance period. The primary structural outcome was changes in tibiofemoral cartilage loss assessed semi-quantitatively (Boston Leeds Knee Osteoarthritis Score (BLOKS) from MRI after the 52 weight maintenance period. 157 participants (82% of the CAROT cohort) with medial and/or lateral knee OA were classified as Unloaders (n = 100) or Loaders (n = 57). The groups showed similar significant changes in symptoms (group difference: -2.4 KOOS points [95% CI -6.8:1.9]) and cartilage loss (group difference: -0.06 BLOKS points [95% CI -0.22:0.11) after 1 year, with no statistically significant differences between Loaders and Unloaders. For obese patients undergoing a significant weight loss, increased knee joint loading for 1 year was not associated with accelerated symptomatic and structural disease progression compared to a similar weight loss group that had reduced ambulatory compressive knee joint loads. NCT00655941. Copyright © 2013 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  9. Cumulative loads increase at the knee joint with slow-speed running compared to faster running: a biomechanical study.

    PubMed

    Petersen, Jesper; Sørensen, Henrik; Nielsen, Rasmus Østergaard

    2015-04-01

    Biomechanical cross-sectional study. To investigate the hypothesis that the cumulative load at the knee during running increases as running speed decreases. The knee joint load per stride decreases as running speed decreases. However, by decreasing running speed, the number of strides per given distance is increased. Running a given distance at a slower speed may increase the cumulative load at the knee joint compared with running the same distance at a higher speed, hence increasing the risk of running-related injuries in the knee. Kinematic and ground reaction force data were collected from 16 recreational runners, during steady-state running with a rearfoot strike pattern at 3 different speeds (mean ± SD): 8.02 ± 0.17 km/h, 11.79 ± 0.21 km/h, and 15.78 ± 0.22 km/h. The cumulative load (cumulative impulse) over a 1000-m distance was calculated at the knee joint on the basis of a standard 3-D inverse-dynamics approach. Based on a 1000-m running distance, the cumulative load at the knee was significantly higher at a slow running speed than at a high running speed (relative difference, 80%). The mean load per stride at the knee increased significantly across all biomechanical parameters, except impulse, following an increase in running speed. Slow-speed running decreases knee joint loads per stride and increases the cumulative load at the knee joint for a given running distance compared to faster running. The primary reason for the increase in cumulative load at slower speeds is an increase in number of strides needed to cover the same distance.

  10. Knee Joint Loads and Surrounding Muscle Forces during Stair Ascent in Patients with Total Knee Replacement

    PubMed Central

    Rasnick, Robert; Standifird, Tyler; Reinbolt, Jeffrey A.; Cates, Harold E.

    2016-01-01

    Total knee replacement (TKR) is commonly used to correct end-stage knee osteoarthritis. Unfortunately, difficulty with stair climbing often persists and prolongs the challenges of TKR patents. Complete understanding of loading at the knee is of great interest in order to aid patient populations, implant manufacturers, rehabilitation, and future healthcare research. Musculoskeletal modeling and simulation approximates joint loading and corresponding muscle forces during a movement. The purpose of this study was to determine if knee joint loadings following TKR are recovered to the level of healthy individuals, and determine the differences in muscle forces causing those loadings. Data from five healthy and five TKR patients were selected for musculoskeletal simulation. Variables of interest included knee joint reaction forces (JRF) and the corresponding muscle forces. A paired samples t-test was used to detect differences between groups for each variable of interest (p<0.05). No differences were observed for peak joint compressive forces between groups. Some muscle force compensatory strategies appear to be present in both the loading and push-off phases. Evidence from knee extension moment and muscle forces during the loading response phase indicates the presence of deficits in TKR in quadriceps muscle force production during stair ascent. This result combined with greater flexor muscle forces resulted in similar compressive JRF during loading response between groups. PMID:27258086

  11. The associations between quadriceps muscle strength, power, and knee joint mechanics in knee osteoarthritis: A cross-sectional study.

    PubMed

    Murray, Amanda M; Thomas, Abbey C; Armstrong, Charles W; Pietrosimone, Brian G; Tevald, Michael A

    2015-12-01

    Abnormal knee joint mechanics have been implicated in the pathogenesis and progression of knee osteoarthritis. Deficits in muscle function (i.e., strength and power) may contribute to abnormal knee joint loading. The associations between quadriceps strength, power and knee joint mechanics remain unclear in knee osteoarthritis. Three-dimensional motion analysis was used to collect peak knee joint angles and moments during the first 50% of stance phase of gait in 33 participants with knee osteoarthritis. Quadriceps strength and power were assessed using a knee extension machine. Strength was quantified as the one repetition maximum. Power was quantified as the peak power produced at 40-90% of the one repetition maximum. Quadriceps strength accounted for 15% of the variance in peak knee flexion angle (P=0.016). Quadriceps power accounted for 20-29% of the variance in peak knee flexion angle (P<0.05). Quadriceps power at 90% of one repetition maximum accounted for 9% of the variance in peak knee adduction moment (P=0.05). These data suggest that quadriceps power explains more variance in knee flexion angle and knee adduction moment during gait in knee osteoarthritis than quadriceps strength. Additionally, quadriceps power at multiple loads is associated with knee joint mechanics and therefore should be assessed at a variety of loads. Taken together, these results indicate that quadriceps power may be a potential target for interventions aimed at changing knee joint mechanics in knee osteoarthritis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Evaluation of an intact, an ACL-deficient, and a reconstructed human knee joint finite element model.

    PubMed

    Vairis, Achilles; Stefanoudakis, George; Petousis, Markos; Vidakis, Nectarios; Tsainis, Andreas-Marios; Kandyla, Betina

    2016-02-01

    The human knee joint has a three-dimensional geometry with multiple body articulations that produce complex mechanical responses under loads that occur in everyday life and sports activities. Understanding the complex mechanical interactions of these load-bearing structures is of use when the treatment of relevant diseases is evaluated and assisting devices are designed. The anterior cruciate ligament (ACL) in the knee is one of four main ligaments that connects the femur to the tibia and is often torn during sudden twisting motions, resulting in knee instability. The objective of this work is to study the mechanical behavior of the human knee joint and evaluate the differences in its response for three different states, i.e., intact, ACL-deficient, and surgically treated (reconstructed) knee. The finite element models corresponding to these states were developed. For the reconstructed model, a novel repair device was developed and patented by the author in previous work. Static load cases were applied, as have already been presented in a previous work, in order to compare the calculated results produced by the two models the ACL-deficient and the surgically reconstructed knee joint, under the exact same loading conditions. Displacements were calculated in different directions for the load cases studied and were found to be very close to those from previous modeling work and were in good agreement with experimental data presented in literature. The developed finite element model for both the intact and the ACL-deficient human knee joint is a reliable tool to study the kinematics of the human knee, as results of this study show. In addition, the reconstructed human knee joint model had kinematic behavior similar to the intact knee joint, showing that such reconstruction devices can restore human knee stability to an adequate extent.

  13. Predicting the Functional Roles of Knee Joint Muscles from Internal Joint Moments.

    PubMed

    Flaxman, Teresa E; Alkjær, Tine; Simonsen, Erik B; Krogsgaard, Michael R; Benoit, Daniel L

    2017-03-01

    Knee muscles are commonly labeled as flexors or extensors and aptly stabilize the knee against sagittal plane loads. However, how these muscles stabilize the knee against adduction-abduction and rotational loads remains unclear. Our study sought 1) to classify muscle roles as they relate to joint stability by quantifying the relationship between individual muscle activation patterns and internal net joint moments in all three loading planes and 2) to determine whether these roles change with increasing force levels. A standing isometric force matching protocol required subjects to modulate ground reaction forces to elicit various combinations and magnitudes of sagittal, frontal, and transverse internal joint moments. Surface EMG measured activities of 10 lower limb muscles. Partial least squares regressions determined which internal moment(s) were significantly related to the activation of individual muscles. Rectus femoris and tensor fasciae latae were classified as moment actuators for knee extension and hip flexion. Hamstrings were classified as moment actuators for hip extension and knee flexion. Gastrocnemius and hamstring muscles were classified as specific joint stabilizers for knee rotation. Vastii were classified as general joint stabilizers because activation was independent of moment generation. Muscle roles did not change with increasing effort levels. Our findings indicate muscle activation is not dependent on anatomical orientation but perhaps on its role in maintaining knee joint stability in the frontal and transverse loading planes. This is useful for delineating the roles of biarticular knee joint muscles and could have implications in robotics, musculoskeletal modeling, sports sciences, and rehabilitation.

  14. Is there a causal link between knee loading and knee osteoarthritis progression? A systematic review and meta-analysis of cohort studies and randomised trials

    PubMed Central

    Henriksen, Marius; Creaby, Mark W; Lund, Hans; Juhl, Carsten; Christensen, Robin

    2014-01-01

    Objective We performed a systematic review, meta-analysis and assessed the evidence supporting a causal link between knee joint loading during walking and structural knee osteoarthritis (OA) progression. Design Systematic review, meta-analysis and application of Bradford Hill's considerations on causation. Data sources We searched MEDLINE, Scopus, AMED, CINAHL and SportsDiscus for prospective cohort studies and randomised controlled trials (RCTs) from 1950 through October 2013. Study eligibility criteria We selected cohort studies and RCTs in which estimates of knee joint loading during walking were used to predict structural knee OA progression assessed by X-ray or MRI. Data analyses Meta-analysis was performed to estimate the combined OR for structural disease progression with higher baseline loading. The likelihood of a causal link between knee joint loading and OA progression was assessed from cohort studies using the Bradford Hill guidelines to derive a 0–4 causation score based on four criteria and examined for confirmation in RCTs. Results Of the 1078 potentially eligible articles, 5 prospective cohort studies were included. The studies included a total of 452 patients relating joint loading to disease progression over 12–72 months. There were very serious limitations associated with the methodological quality of the included studies. The combined OR for disease progression was 1.90 (95% CI 0.85 to 4.25; I2=77%) for each one-unit increment in baseline knee loading. The combined causation score was 0, indicating no causal association between knee loading and knee OA progression. No RCTs were found to confirm or refute the findings from the cohort studies. Conclusions There is very limited and low-quality evidence to support for a causal link between knee joint loading during walking and structural progression of knee OA. Trial registration number CRD42012003253 PMID:25031196

  15. Is there a causal link between knee loading and knee osteoarthritis progression? A systematic review and meta-analysis of cohort studies and randomised trials.

    PubMed

    Henriksen, Marius; Creaby, Mark W; Lund, Hans; Juhl, Carsten; Christensen, Robin

    2014-07-15

    We performed a systematic review, meta-analysis and assessed the evidence supporting a causal link between knee joint loading during walking and structural knee osteoarthritis (OA) progression. Systematic review, meta-analysis and application of Bradford Hill's considerations on causation. We searched MEDLINE, Scopus, AMED, CINAHL and SportsDiscus for prospective cohort studies and randomised controlled trials (RCTs) from 1950 through October 2013. We selected cohort studies and RCTs in which estimates of knee joint loading during walking were used to predict structural knee OA progression assessed by X-ray or MRI. Meta-analysis was performed to estimate the combined OR for structural disease progression with higher baseline loading. The likelihood of a causal link between knee joint loading and OA progression was assessed from cohort studies using the Bradford Hill guidelines to derive a 0-4 causation score based on four criteria and examined for confirmation in RCTs. Of the 1078 potentially eligible articles, 5 prospective cohort studies were included. The studies included a total of 452 patients relating joint loading to disease progression over 12-72 months. There were very serious limitations associated with the methodological quality of the included studies. The combined OR for disease progression was 1.90 (95% CI 0.85 to 4.25; I(2)=77%) for each one-unit increment in baseline knee loading. The combined causation score was 0, indicating no causal association between knee loading and knee OA progression. No RCTs were found to confirm or refute the findings from the cohort studies. There is very limited and low-quality evidence to support for a causal link between knee joint loading during walking and structural progression of knee OA. CRD42012003253. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  16. Implementation of a gait cycle loading into healthy and meniscectomised knee joint models with fibril-reinforced articular cartilage.

    PubMed

    Mononen, Mika E; Jurvelin, Jukka S; Korhonen, Rami K

    2015-01-01

    Computational models can be used to evaluate the functional properties of knee joints and possible risk locations within joints. Current models with fibril-reinforced cartilage layers do not provide information about realistic human movement during walking. This study aimed to evaluate stresses and strains within a knee joint by implementing load data from a gait cycle in healthy and meniscectomised knee joint models with fibril-reinforced cartilages. A 3D finite element model of a knee joint with cartilages and menisci was created from magnetic resonance images. The gait cycle data from varying joint rotations, translations and axial forces were taken from experimental studies and implemented into the model. Cartilage layers were modelled as a fibril-reinforced poroviscoelastic material with the menisci considered as a transversely isotropic elastic material. In the normal knee joint model, relatively high maximum principal stresses were specifically predicted to occur in the medial condyle of the knee joint during the loading response. Bilateral meniscectomy increased stresses, strains and fluid pressures in cartilage on the lateral side, especially during the first 50% of the stance phase of the gait cycle. During the entire stance phase, the superficial collagen fibrils modulated stresses of cartilage, especially in the medial tibial cartilage. The present computational model with a gait cycle and fibril-reinforced biphasic cartilage revealed time- and location-dependent differences in stresses, strains and fluid pressures occurring in cartilage during walking. The lateral meniscus was observed to have a more significant role in distributing loads across the knee joint than the medial meniscus, suggesting that meniscectomy might initiate a post-traumatic process leading to osteoarthritis at the lateral compartment of the knee joint.

  17. Patellofemoral Joint Loads During Running at the Time of Return to Sport in Elite Athletes With ACL Reconstruction.

    PubMed

    Herrington, Lee; Alarifi, Saud; Jones, Richard

    2017-10-01

    Patellofemoral joint pain and degeneration are common in patients who undergo anterior cruciate ligament reconstruction (ACLR). The presence of patellofemoral joint pain significantly affects the patient's ability to continue sport participation and may even affect participation in activities of daily living. The mechanisms behind patellofemoral joint pain and degeneration are unclear, but previous research has identified altered patellofemoral joint loading in individuals with patellofemoral joint pain when running. It is unclear whether this process occurs after ACLR. To assess the patellofemoral joint stresses during running in ACLR knees and compare the findings to the noninjured knee and matched control knees. Controlled laboratory study. Thirty-four elite sports practitioners who had undergone ACLR and 34 age- and sex-matched controls participated in the study. The participants' running gait was assessed via 3D motion capture, and knee loads and forces were calculated by use of inverse dynamics. A significance difference was found in knee extensor moment, knee flexion angles, patellofemoral contact force (about 23% greater), and patellofemoral contact pressure (about 27% greater) between the ACLR and the noninjured limb ( P ≤ .04) and between the ACLR and the control limb ( P ≤ .04); no significant differences were found between the noninjured and control limbs ( P ≥ .44). Significantly greater levels of patellofemoral joint stress and load were found in the ACLR knee compared with the noninjured and control knees. Altered levels of patellofemoral stress in the ACLR knee during running may predispose individuals to patellofemoral joint pain.

  18. The short-term effects of running on the deformation of knee articular cartilage and its relationship to biomechanical loads at the knee.

    PubMed

    Boocock, M; McNair, P; Cicuttini, F; Stuart, A; Sinclair, T

    2009-07-01

    To investigate the short-term effects of recreational running on the deformation of knee articular cartilage and to examine the relationship between changes in knee cartilage volume and biomechanical modulators of knee joint load. Twenty healthy volunteers participated in a two phase cross-sectional study. Session 1 involved Magnetic Resonance Imaging (MRI) of femoral and tibial cartilage volumes prior to and following a 30 min period of relaxed sitting, which was directly followed by a recreational run of 5000 steps. Subsequently, all participants undertook a laboratory study of their running gait to compare biomechanical derived measures of knee joint loading with changes in cartilage volume. Estimates of knee joint load were determined using a rigid-link segment, dynamic biomechanical model of the lower limbs and a simplified muscle model. Running resulted in significant deformation of the medial (5.3%, P<0.01) and lateral femoral cartilage (4.0%, P<0.05) and lateral aspect of the tibial cartilage (5.7%, P<0.01), with no significant differences between genders. Maximum compression stress was significantly correlated with percentage changes in lateral femoral cartilage volume (r(2)=0.456, P<0.05). No other biomechanical variables correlated with volume changes. Limited evidence was found linking biomechanical measures of knee joint loading and observed short-term deformation of knee articular cartilage volume following running. Further enhancement of knee muscle modelling and analysis of stress distribution across cartilage are needed if we are to fully understand the contribution of biomechanical factors to knee joint loading and the pathogenesis of knee osteoarthritis (OA).

  19. Knee Joint Loading during Single-Leg Forward Hopping.

    PubMed

    Krupenevich, Rebecca L; Pruziner, Alison L; Miller, Ross H

    2017-02-01

    Increased or abnormal loading on the intact limb is thought to contribute to the relatively high risk of knee osteoarthritis in this limb for individuals with unilateral lower limb loss. This theory has been assessed previously by studying walking, but knee joint loading during walking is often similar between individuals with and without limb loss, prompting assessment of other movements that may place unusual loads on the knee. One such movement, hopping, is a form of locomotion that individuals with unilateral lower limb loss may situationally use instead of walking, but the mechanical effects of hopping on the intact limb are unknown. Compare knee joint kinetics of healthy adults during single-leg forward hopping compared to walking, a more traditional form of locomotion. Twenty-four healthy adults walked and hopped at self-selected speeds of 1.5 and 2.3 m·s, respectively. Joint moments were calculated using inverse dynamics. A paired Student's t-test was utilized to compare peak, impulse, and loading rate (LR) of knee adduction moment (KAM), and peak knee flexion moment (KFM) between walking and hopping. Peak KFM and KAM LR were greater during hopping compared to walking (peak KFM: 20.73% vs 5.51% body weight (BW) × height (Ht), P < 0.001; KAM LR: 0.47 vs. 0.33 BW·Ht·s, P = 0.01). Kinetic measures affecting knee joint loading are greater in hopping compared to walking. It may be advisable to limit single-leg forward hopping in the limb loss population until it is known if these loads increase knee osteoarthritis risk.

  20. Soldier-relevant body borne loads increase knee joint contact force during a run-to-stop maneuver.

    PubMed

    Ramsay, John W; Hancock, Clifford L; O'Donovan, Meghan P; Brown, Tyler N

    2016-12-08

    The purpose of this study was to understand the effects of load carriage on human performance, specifically during a run-to-stop (RTS) task. Using OpenSim analysis tools, knee joint contact force, grounds reaction force, leg stiffness and lower extremity joint angles and moments were determined for nine male military personnel performing a RTS under three load configurations (light, ~6kg, medium, ~20kg, and heavy, ~40kg). Subject-based means for each biomechanical variable were submitted to repeated measures ANOVA to test the effects of load. During the RTS, body borne load significantly increased peak knee joint contact force by 1.2 BW (p<0.001) and peak vertical (p<0.001) and anterior-posterior (p=0.002) ground reaction forces by 0.6 BW and 0.3 BW, respectively. Body borne load also had a significant effect on hip (p=0.026) posture with the medium load and knee (p=0.046) posture with the heavy load. With the heavy load, participants exhibited a substantial, albeit non-significant increase in leg stiffness (p=0.073 and d=0.615). Increases in joint contact force exhibited during the RTS were primarily due to greater GRFs that impact the soldier with each incremental addition of body borne load. The stiff leg, extended knee and large braking force the soldiers exhibited with the heavy load suggests their injury risk may be greatest with that specific load configuration. Further work is needed to determine if the biomechanical profile exhibited with the heavy load configuration translates to unsafe shear forces at the knee joint and consequently, a higher likelihood of injury. Published by Elsevier Ltd.

  1. Managing Knee Osteoarthritis: The Effects of Body Weight Supported Physical Activity on Joint Pain, Function, and Thigh Muscle Strength.

    PubMed

    Peeler, Jason; Christian, Mathew; Cooper, Juliette; Leiter, Jeffrey; MacDonald, Peter

    2015-11-01

    To determine the effect of a 12-week lower body positive pressure (LBPP)-supported low-load treadmill walking program on knee joint pain, function, and thigh muscle strength in overweight patients with knee osteoarthritis (OA). Prospective, observational, repeated measures investigation. Community-based, multidisciplinary sports medicine clinic. Thirty-one patients aged between 55 and 75 years, with a body mass index ≥25 kg/m and mild-to-moderate knee OA. Twelve-week LBPP-supported low-load treadmill walking regimen. Acute knee joint pain (visual analog scale) during full weight bearing treadmill walking, chronic knee pain, and joint function [Knee Injury and Osteoarthritis Outcome Score (KOOS) questionnaire] during normal activities of daily living, and thigh muscle strength (isokinetic testing). Appropriate methods of statistical analysis were used to compare data from baseline and follow-up evaluation. Participants reported significant improvements in knee joint pain and function and demonstrated significant increases in thigh muscle strength about the degenerative knee. Participants also experienced significant reductions in acute knee pain during full weight bearing treadmill walking and required dramatically less LBPP support to walk pain free on the treadmill. Data suggest that an LBPP-supported low-load exercise regimen can be used to significantly diminish knee pain, enhance joint function, and increase thigh muscle strength, while safely promoting pain-free walking exercise in overweight patients with knee OA. These findings have important implications for the development of nonoperative treatment strategies that can be used in the management of joint symptoms associated with progressive knee OA in at-risk patient populations. This research suggests that LBPP-supported low-load walking is a safe user-friendly mode of exercise that can be successfully used in the management of day-to-day joint symptoms associated with knee OA, helping to improve the physical health, quality of life, and social well-being of North America's aging population.

  2. A Study of Knee Joint Kinematics and Mechanics using a Human FE Model.

    PubMed

    Kitagawa, Yuichi; Hasegawa, Junji; Yasuki, Tsuyoshi; Iwamoto, Masami; Miki, Kazuo

    2005-11-01

    Posterior translation of the tibia with respect to the femur can stretch the posterior cruciate ligament (PCL). Fifteen millimeters of relative displacement between the femur and tibia is known as the Injury Assessment Reference Value (IARV) for the PCL injury. Since the anterior protuberance of the tibial plateau can be the first site of contact when the knee is flexed, the knee bolster is generally designed with an inclined surface so as not to directly load the projection in frontal crashes. It should be noted, however, that the initial flexion angle of the occupant knee can vary among individuals and the knee flexion angle can change due to the occupant motion. The behavior of the tibial protuberance related to the knee flexion angle has not been described yet. The instantaneous angle of the knee joint at the timing of restraining the knee should be known to manage the geometry and functions of knee restraint devices. The purposes of this study are first to understand the kinematics of the knee joint during flexion, and second to characterize the mechanics of the knee joint under anterior-posterior loading. A finite element model of the knee joint, extracted from the Total Human Model for Safety (THUMS), was used to analyze the mechanism. The model was validated against kinematics and mechanical responses of the human knee joint. By tracking the relative positions and angles between the patella and the tibia in a knee flexing simulation, the magnitude of the tibial anterior protuberance was described as a function of the knee joint angle. The model revealed that the mechanics of the knee joint was characterized as a combination of stiffness of the patella-femur structure and the PCL It was also found that the magnitude of the tibial anterior protuberance determined the amount of initial stretch of the PCL in anterior-posterior loading. Based on the knee joint kinematics and mechanics, an interference boundary was proposed for different knee flexion angles, so as not to directly load the anterior protuberance of the tibial plateau in restraining of the knee. A frontal crash simulation was performed using a partial vehicle model with the THUMS seated. The performance and effects of the knee airbag, as one of the candidates for knee restraint devices, were evaluated through the simulation.

  3. Improved Automatically Locking/Unlocking Orthotic Knee Joint

    NASA Technical Reports Server (NTRS)

    Weddendorf, Bruce

    1995-01-01

    Proposed orthotic knee joint improved version of one described in "Automatically Locking/Unlocking Orthotic Knee Joint" (MFS-28633). Locks automatically upon initial application of radial force (wearer's weight) and unlocks automatically, but only when all loads (radial force and bending) relieved. Joints lock whenever wearer applies weight to knee at any joint angle between full extension and 45 degree bend. Both devices offer increased safety and convenience relative to conventional orthotic knee joints.

  4. Normal axial alignment of the lower extremity and load-bearing distribution at the knee.

    PubMed

    Hsu, R W; Himeno, S; Coventry, M B; Chao, E Y

    1990-06-01

    Based on a series of 120 normal subjects of different gender and age, the geometry of the knee joint was analyzed using a full-length weight-bearing roentgenogram of the lower extremity. A special computer program based on the theory of a rigid body spring model was applied to calculate the important anatomic and biomechanical factors of the knee joint. The tibiofemoral mechanical angle was 1.2 degrees varus. Hence, it is difficult to rationalize the 3 degree varus placement of the tibial component in total knee arthroplasty suggested by some authors. The distal femoral anatomic valgus (measured from the lower one-half of the femur) was 4.2 degrees in reference to its mechanical axis. This angle became 4.9 degrees when the full-length femoral anatomic axis was used. When simulating a one-legged weight-bearing stance by shifting the upper-body gravity closer to the knee joint, 75% of the knee joint load passed through the medial tibial plateau. The knee joint-line obliquity was more varus in male subjects. The female subjects had a higher peak joint pressure and a greater patello-tibial Q angle. Age had little effect on the factors relating to axial alignment of the lower extremity and load transmission through the knee joint.

  5. Joint angles of the ankle, knee, and hip and loading conditions during split squats.

    PubMed

    Schütz, Pascal; List, Renate; Zemp, Roland; Schellenberg, Florian; Taylor, William R; Lorenzetti, Silvio

    2014-06-01

    The aim of this study was to quantify how step length and the front tibia angle influence joint angles and loading conditions during the split squat exercise. Eleven subjects performed split squats with an additional load of 25% body weight applied using a barbell. Each subject's movements were recorded using a motion capture system, and the ground reaction force was measured under each foot. The joint angles and loading conditions were calculated using a cluster-based kinematic approach and inverse dynamics modeling respectively. Increases in the tibia angle resulted in a smaller range of motion (ROM) of the front knee and a larger ROM of the rear knee and hip. The external flexion moment in the front knee/hip and the external extension moment in the rear hip decreased as the tibia angle increased. The flexion moment in the rear knee increased as the tibia angle increased. The load distribution between the legs changed < 25% when split squat execution was varied. Our results describing the changes in joint angles and the resulting differences in the moments of the knee and hip will allow coaches and therapists to adapt the split squat exercise to the individual motion and load demands of athletes.

  6. No Exacerbation of Knee Joint Pain and Effusion Following Preoperative Progressive Resistance Training in Patients Scheduled for Total Knee Arthroplasty: Secondary Analyses From a Randomized Controlled Trial.

    PubMed

    Skoffer, Birgit; Dalgas, Ulrik; Maribo, Thomas; Søballe, Kjeld; Mechlenburg, Inger

    2017-11-09

    Preoperative progressive resistance training (PRT) is controversial in patients scheduled for total knee arthroplasty (TKA), because of the concern that it may exacerbate knee joint pain and effusion. To examine whether preoperative PRT initiated 5 weeks prior to TKA would exacerbate pain and knee effusion, and would allow a progressively increased training load throughout the training period that would subsequently increase muscle strength. Secondary analyses from a randomized controlled trial. University Hospital and a Regional Hospital. A total of 30 patients who were scheduled for TKA due to osteoarthritis and assigned as the intervention group. Patients underwent unilateral PRT (3 sessions per week). Exercise loading was 12 repetitions maximum (RM) with progression toward 8 RM. The training program consisted of 6 exercises performed unilaterally. Before and after each training session, knee joint pain was rated on an 11-point scale, effusion was assessed by measuring the knee joint circumference, and training load was recorded. The first and last training sessions were initiated by 1 RM testing of unilateral leg press, unilateral knee extension, and unilateral knee flexion. The median pain change score from before to after each training session was 0 at all training sessions. The average increase in knee joint effusion across the 12 training sessions was a mean 0.16 cm ± 0.23 cm. No consistent increase in knee joint effusion after training sessions during the training period was found (P = .21). Training load generally increased, and maximal muscle strength improved as follows: unilateral leg press: 18% ± 30% (P = .03); unilateral knee extension: 81% ± 156% (P < .001); and unilateral knee flexion: 53% ± 57% (P < .001). PRT of the affected leg initiated shortly before TKA does not exacerbate knee joint pain and effusion, despite a substantial progression in loading and increased muscle strength. Concerns for side effects such as pain and effusion after PRT seem unfounded. To be determined. Copyright © 2017. Published by Elsevier Inc.

  7. Gender dimorphic ACL strain in response to combined dynamic 3D knee joint loading: implications for ACL injury risk.

    PubMed

    Mizuno, Kiyonori; Andrish, Jack T; van den Bogert, Antonie J; McLean, Scott G

    2009-12-01

    While gender-based differences in knee joint anatomies/laxities are well documented, the potential for them to precipitate gender-dimorphic ACL loading and resultant injury risk has not been considered. To this end, we generated gender-specific models of ACL strain as a function of any six degrees of freedom (6DOF) knee joint load state via a combined cadaveric and analytical approach. Continuously varying joint forces and torques were applied to five male and five female cadaveric specimens and recorded along with synchronous knee flexion and ACL strain data. All data (approximately 10,000 samples) were submitted to specimen-specific regression analyses, affording ACL strain predictions as a function of the combined 6 DOF knee loads. Following individual model verifications, generalized gender-specific models were generated and subjected to 6 DOF external load scenarios consistent with both a clinical examination and a dynamic sports maneuver. The ensuing model-based strain predictions were subsequently examined for gender-based discrepancies. Male and female specimen-specific models predicted ACL strain within 0.51%+/-0.10% and 0.52%+/-0.07% of the measured data respectively, and explained more than 75% of the associated variance in each case. Predicted female ACL strains were also significantly larger than respective male values for both simulated 6 DOF load scenarios. Outcomes suggest that the female ACL will rupture in response to comparatively smaller external load applications. Future work must address the underlying anatomical/laxity contributions to knee joint mechanical and resultant ACL loading, ultimately affording prevention strategies that may cater to individual joint vulnerabilities.

  8. Changes in In Vivo Knee Loading with a Variable-Stiffness Intervention Shoe Correlate with Changes in the Knee Adduction Moment

    PubMed Central

    Erhart, Jennifer C.; Dyrby, Chris O.; D'Lima, Darryl D.; Colwell, Clifford W.; Andriacchi, Thomas P.

    2010-01-01

    External knee adduction moment can be reduced using footwear interventions, but the exact changes in in vivo medial joint loading remain unknown. An instrumented knee replacement was used to assess changes in in vivo medial joint loading in a single patient walking with a variable-stiffness intervention shoe. We hypothesized that during walking with a load modifying variable-stiffness shoe intervention: (1) the first peak knee adduction moment will be reduced compared to a subject's personal shoes; (2) the first peak in vivo medial contact force will be reduced compared to personal shoes; and (3) the reduction in knee adduction moment will be correlated with the reduction in medial contact force. The instrumentation included a motion capture system, force plate, and the instrumented knee prosthesis. The intervention shoe reduced the first peak knee adduction moment (13.3%, p=0.011) and medial compartment joint contact force (22%; p=0.008) compared to the personal shoe. The change in first peak knee adduction moment was significantly correlated with the change in first peak medial contact force (R2=0.67, p=0.007). Thus, for a single subject with a total knee prosthesis the variable-stiffness shoe reduces loading on the affected compartment of the joint. The reductions in the external knee adduction moment are indicative of reductions in in vivo medial compressive force with this intervention. PMID:20973058

  9. The effects of load on system and lower-body joint kinetics during jump squats.

    PubMed

    Moir, Gavin L; Gollie, Jared M; Davis, Shala E; Guers, John J; Witmer, Chad A

    2012-11-01

    To investigate the effects of different loads on system and lower-body kinetics during jump squats, 12 resistance-trained men performed jumps under different loading conditions: 0%, 12%, 27%, 42%, 56%, 71%, and 85% of 1-repetition maximum (1-RM). System power output was calculated as the product of the vertical component of the ground reaction force and the vertical velocity of the bar during its ascent. Joint power output was calculated during bar ascent for the hip, knee, and ankle joints, and was also summed across the joints. System power output and joint power at knee and ankle joints were maximized at 0% 1-RM (p < 0.001) and followed the linear trends (p < 0.001) caused by power output decreasing as the load increased. Power output at the hip was maximized at 42% 1-RM (p = 0.016) and followed a quadratic trend (p = 0.030). Summed joint power could be predicted from system power (p < 0.05), while system power could predict power at the knee and ankle joints under some of the loading conditions. Power at the hip could not be predicted from system power. System power during loaded jumps reflects the power at the knee and ankle, while power at the hip does not correspond to system power.

  10. Quantifying in vivo laxity in the anterior cruciate ligament and individual knee joint structures.

    PubMed

    Westover, L M; Sinaei, N; Küpper, J C; Ronsky, J L

    2016-11-01

    A custom knee loading apparatus (KLA), when used in conjunction with magnetic resonance imaging, enables in vivo measurement of the gross anterior laxity of the knee joint. A numerical model was applied to the KLA to understand the contribution of the individual joint structures and to estimate the stiffness of the anterior-cruciate ligament (ACL). The model was evaluated with a cadaveric study using an in situ knee loading apparatus and an ElectroForce test system. A constrained optimization solution technique was able to predict the restraining forces within the soft-tissue structures and joint contact. The numerical model presented here allowed in vivo prediction of the material stiffness parameters of the ACL in response to applied anterior loading. Promising results were obtained for in vivo load sharing within the structures. The numerical model overestimated the ACL forces by 27.61-92.71%. This study presents a novel approach to estimate ligament stiffness and provides the basis to develop a robust and accurate measure of in vivo knee joint laxity.

  11. Analysis of the load on the knee joint and vertebral column with changes in squatting depth and weight load.

    PubMed

    Hartmann, Hagen; Wirth, Klaus; Klusemann, Markus

    2013-10-01

    It has been suggested that deep squats could cause an increased injury risk of the lumbar spine and the knee joints. Avoiding deep flexion has been recommended to minimize the magnitude of knee-joint forces. Unfortunately this suggestion has not taken the influence of the wrapping effect, functional adaptations and soft tissue contact between the back of thigh and calf into account. The aim of this literature review is to assess whether squats with less knee flexion (half/quarter squats) are safer on the musculoskeletal system than deep squats. A search of relevant scientific publications was conducted between March 2011 and January 2013 using PubMed. Over 164 articles were included in the review. There are no realistic estimations of knee-joint forces for knee-flexion angles beyond 50° in the deep squat. Based on biomechanical calculations and measurements of cadaver knee joints, the highest retropatellar compressive forces and stresses can be seen at 90°. With increasing flexion, the wrapping effect contributes to an enhanced load distribution and enhanced force transfer with lower retropatellar compressive forces. Additionally, with further flexion of the knee joint a cranial displacement of facet contact areas with continuous enlargement of the retropatellar articulating surface occurs. Both lead to lower retropatellar compressive stresses. Menisci and cartilage, ligaments and bones are susceptible to anabolic metabolic processes and functional structural adaptations in response to increased activity and mechanical influences. Concerns about degenerative changes of the tendofemoral complex and the apparent higher risk for chondromalacia, osteoarthritis, and osteochondritis in deep squats are unfounded. With the same load configuration as in the deep squat, half and quarter squat training with comparatively supra-maximal loads will favour degenerative changes in the knee joints and spinal joints in the long term. Provided that technique is learned accurately under expert supervision and with progressive training loads, the deep squat presents an effective training exercise for protection against injuries and strengthening of the lower extremity. Contrary to commonly voiced concern, deep squats do not contribute increased risk of injury to passive tissues.

  12. Walking velocity and step length adjustments affect knee joint contact forces in healthy weight and obese adults.

    PubMed

    Milner, Clare E; Meardon, Stacey A; Hawkins, Jillian L; Willson, John D

    2018-04-28

    Knee osteoarthritis is a major public health problem and adults with obesity are particularly at risk. One approach to alleviating this problem is to reduce the mechanical load at the joint during daily activity. Adjusting temporospatial parameters of walking could mitigate cumulative knee joint mechanical loads. The purpose of this study was to determine how adjustments to velocity and step length affects knee joint loading in healthy weight adults and adults with obesity. We collected three-dimensional gait analysis data on 10 adults with a normal body mass index and 10 adults with obesity during over ground walking in nine different conditions. In addition to preferred velocity and step length, we also conducted combinations of 15% increased and decreased velocity and step length. Peak tibiofemoral joint impulse and knee adduction angular impulse were reduced in the decreased step length conditions in both healthy weight adults (main effect) and those with obesity (interaction effect). Peak knee joint adduction moment was also reduced with decreased step length, and with decreased velocity in both groups. We conclude from these results that adopting shorter step lengths during daily activity and when walking for exercise can reduce mechanical stimuli associated with articular cartilage degenerative processes in adults with and without obesity. Thus, walking with reduced step length may benefit adults at risk for disability due to knee osteoarthritis. Adopting a shorter step length during daily walking activity may reduce knee joint loading and thus benefit those at risk for knee cartilage degeneration. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 9999:XX-XX, 2018. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  13. Gender Dimorphic ACL Strain In Response to Combined Dynamic 3D Knee Joint Loading: Implications for ACL Injury Risk

    PubMed Central

    Mizuno, Kiyonori; Andrish, Jack T.; van den Bogert, Antonie J.; McLean, Scott G.

    2009-01-01

    While gender-based differences in knee joint anatomies/laxities are well documented, the potential for them to precipitate gender-dimorphic ACL loading and resultant injury risk has not been considered. To this end, we generated gender-specific models of ACL strain as a function of any six degrees of freedom (6DOF) knee joint load state via a combined cadaveric and analytical approach. Continuously varying joint forces and torques were applied to five male and five female cadaveric specimens and recorded along with synchronous knee flexion and ACL strain data. All data (~10,000 samples) were submitted to specimen-specific regression analyses, affording ACL strain predictions as a function of the combined 6 DOF knee loads. Following individual model verifications, generalized gender-specific models were generated and subjected to 6 DOF external load scenarios consistent with both a clinical examination and a dynamic sports maneuver. The ensuing model-based strain predictions were subsequently examined for gender-based discrepancies. Male and female specimen specific models predicted ACL strain within 0.51% ± 0.10% and 0.52% ± 0.07% of the measured data respectively, and explained more than 75% of the associated variance in each case. Predicted female ACL strains were also significantly larger than respective male values for both of simulated 6 DOF load scenarios. Outcomes suggest that the female ACL will rupture in response to comparatively smaller external load applications. Future work must address the underlying anatomical/laxity contributions to knee joint mechanical and resultant ACL loading, ultimately affording prevention strategies that may cater to individual joint vulnerabilities. PMID:19464897

  14. A neural network approach for determining gait modifications to reduce the contact force in knee joint implant.

    PubMed

    Ardestani, Marzieh Mostafavizadeh; Chen, Zhenxian; Wang, Ling; Lian, Qin; Liu, Yaxiong; He, Jiankang; Li, Dichen; Jin, Zhongmin

    2014-10-01

    There is a growing interest in non-surgical gait rehabilitation treatments to reduce the loading in the knee joint. In particular, synergetic kinematic changes required for joint offloading should be determined individually for each subject. Previous studies for gait rehabilitation designs are typically relied on a "trial-and-error" approach, using multi-body dynamic (MBD) analysis. However MBD is fairly time demanding which prevents it to be used iteratively for each subject. This study employed an artificial neural network to develop a cost-effective computational framework for designing gait rehabilitation patterns. A feed forward artificial neural network (FFANN) was trained based on a number of experimental gait trials obtained from literature. The trained network was then hired to calculate the appropriate kinematic waveforms (output) needed to achieve desired knee joint loading patterns (input). An auxiliary neural network was also developed to update the ground reaction force and moment profiles with respect to the predicted kinematic waveforms. The feasibility and efficiency of the predicted kinematic patterns were then evaluated through MBD analysis. Results showed that FFANN-based predicted kinematics could effectively decrease the total knee joint reaction forces. Peak values of the resultant knee joint forces, with respect to the bodyweight (BW), were reduced by 20% BW and 25% BW in the midstance and the terminal stance phases. Impulse values of the knee joint loading patterns were also decreased by 17% BW*s and 24%BW*s in the corresponding phases. The FFANN-based framework suggested a cost-effective forward solution which directly calculated the kinematic variations needed to implement a given desired knee joint loading pattern. It is therefore expected that this approach provides potential advantages and further insights into knee rehabilitation designs. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. Knee Osteoarthritis Treatment with the KineSpring Knee Implant System: A Report of Two Cases

    PubMed Central

    Hayes, David A.; Miller, Larry E.; Block, Jon E.

    2012-01-01

    Osteoarthritis (OA) is a leading cause of disability in middle-aged and older adults with the prevalence expected to increase by 40% by 2025. This dramatic projected increase in OA reflects, in large part, the alarming obesity epidemic. Indeed, it is now well understood that abnormal loading across the knee joint due to malalignment and/or excessive weight gain is responsible for accelerating OA progression. Consequently, there is a therapeutic need for alternative knee OA treatments that directly address joint overload to fill the gap between ineffective conservative care and invasive joint-modifying surgical procedures. We describe two cases that presented with bilateral knee OA resistant to conservative treatments, each with one knee previously and unsuccessfully treated with high tibial osteotomy to improve alignment and the contralateral knee successfully treated with a joint-preserving, load-absorbing implant (KineSpring Knee Implant System). PMID:23304590

  16. A preliminary study on effects of increment of loads to lower extremity joints during kettlebell swing activity

    NASA Astrophysics Data System (ADS)

    Zin, Muhammad Athif Mat; Rambely, Azmin Sham; Ariff, Noratiqah Mohd

    2018-04-01

    The purpose of the study was to determine the effects of increment of loads to lower extremity joints during the two-hand kettlebell swing (KS) activity with loads of 4 kg, 6 kg and 8 kg. Three male adults participated in this study. Subjects were required to perform a two-hand KS with three different loads which were 4 kg, 6 kg and 8 kg. A Vicon Nexus system (v1.5.2) with three infrared cameras adjusted with 100 Hz speed were used to capture KS motion to produce kinematics data for lower extremity joints which were ankle, knee and hip joints. The results showed that mean maximum flexion angle (MFA) of ankle, knee and hip joints decreased as load increased. Mean MFA of knee joint was the highest while mean MFA of ankle joint was the smallest recorded. Mean MFA of ipsilateral leg was higher than that of contralateral leg for a right-dominant subject.

  17. Computational knee ligament modeling using experimentally determined zero-load lengths.

    PubMed

    Bloemker, Katherine H; Guess, Trent M; Maletsky, Lorin; Dodd, Kevin

    2012-01-01

    This study presents a subject-specific method of determining the zero-load lengths of the cruciate and collateral ligaments in computational knee modeling. Three cadaver knees were tested in a dynamic knee simulator. The cadaver knees also underwent manual envelope of motion testing to find their passive range of motion in order to determine the zero-load lengths for each ligament bundle. Computational multibody knee models were created for each knee and model kinematics were compared to experimental kinematics for a simulated walk cycle. One-dimensional non-linear spring damper elements were used to represent cruciate and collateral ligament bundles in the knee models. This study found that knee kinematics were highly sensitive to altering of the zero-load length. The results also suggest optimal methods for defining each of the ligament bundle zero-load lengths, regardless of the subject. These results verify the importance of the zero-load length when modeling the knee joint and verify that manual envelope of motion measurements can be used to determine the passive range of motion of the knee joint. It is also believed that the method described here for determining zero-load length can be used for in vitro or in vivo subject-specific computational models.

  18. Effects of changing speed on knee and ankle joint load during walking and running.

    PubMed

    de David, Ana Cristina; Carpes, Felipe Pivetta; Stefanyshyn, Darren

    2015-01-01

    Joint moments can be used as an indicator of joint loading and have potential application for sports performance and injury prevention. The effects of changing walking and running speeds on joint moments for the different planes of motion still are debatable. Here, we compared knee and ankle moments during walking and running at different speeds. Data were collected from 11 recreational male runners to determine knee and ankle joint moments during different conditions. Conditions include walking at a comfortable speed (self-selected pacing), fast walking (fastest speed possible), slow running (speed corresponding to 30% slower than running) and running (at 4 m · s(-1) ± 10%). A different joint moment pattern was observed between walking and running. We observed a general increase in joint load for sagittal and frontal planes as speed increased, while the effects of speed were not clear in the transverse plane moments. Although differences tend to be more pronounced when gait changed from walking to running, the peak moments, in general, increased when speed increased from comfortable walking to fast walking and from slow running to running mainly in the sagittal and frontal planes. Knee flexion moment was higher in walking than in running due to larger knee extension. Results suggest caution when recommending walking over running in an attempt to reduce knee joint loading. The different effects of speed increments during walking and running should be considered with regard to the prevention of injuries and for rehabilitation purposes.

  19. Dynamic simulation of knee-joint loading during gait using force-feedback control and surrogate contact modelling.

    PubMed

    Walter, Jonathan P; Pandy, Marcus G

    2017-10-01

    The aim of this study was to perform multi-body, muscle-driven, forward-dynamics simulations of human gait using a 6-degree-of-freedom (6-DOF) model of the knee in tandem with a surrogate model of articular contact and force control. A forward-dynamics simulation incorporating position, velocity and contact force-feedback control (FFC) was used to track full-body motion capture data recorded for multiple trials of level walking and stair descent performed by two individuals with instrumented knee implants. Tibiofemoral contact force errors for FFC were compared against those obtained from a standard computed muscle control algorithm (CMC) with a 6-DOF knee contact model (CMC6); CMC with a 1-DOF translating hinge-knee model (CMC1); and static optimization with a 1-DOF translating hinge-knee model (SO). Tibiofemoral joint loads predicted by FFC and CMC6 were comparable for level walking, however FFC produced more accurate results for stair descent. SO yielded reasonable predictions of joint contact loading for level walking but significant differences between model and experiment were observed for stair descent. CMC1 produced the least accurate predictions of tibiofemoral contact loads for both tasks. Our findings suggest that reliable estimates of knee-joint loading may be obtained by incorporating position, velocity and force-feedback control with a multi-DOF model of joint contact in a forward-dynamics simulation of gait. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  20. The effects of the sagittal plane malpositioning of the patella and concomitant quadriceps hypotrophy on the patellofemoral joint: a finite element analysis.

    PubMed

    Aksahin, Ertugrul; Kocadal, Onur; Aktekin, Cem N; Kaya, Defne; Pepe, Murad; Yılmaz, Serdar; Yuksel, H Yalcin; Bicimoglu, Ali

    2016-03-01

    Anterior knee pain is a common symptom after intramedullary nailing in tibia shaft fracture. Moreover, patellofemoral malalignment is also known to be a major reason for anterior knee pain. Patellofemoral malalignment predisposes to increased loading in patellar cartilage. In the previous study, we have demonstrated the quadriceps atrophy and patellofemoral malalignment after intramedullary nailing due to tibia shaft fracture. In this study, our aim was to clarify the effects of quadriceps atrophy and patellofemoral malalignment with the pathologic loading on the joint cartilage. Mesh models of patellofemoral joint were constructed with CT images and integrated with soft tissue components such as menisci and ligaments. Physiological and sagittal tilt models during extension and flexion at 15°, 30° and 60° were created generating eight models. All the models were applied with 137 N force to present the effects of normal loading and 115.7 N force for the simulation of quadriceps atrophy. Different degrees of loading were applied to evaluate the joint contact area and pressure value with the finite element analysis. There was increased patellofemoral contact area in patellar tilt models with respect to normal models. The similar loading patterns were diagnosed in all models at 0° and 15° knee flexion when 137 N force was applied. Higher loading values were obtained at 30° and 60° knee flexions in sagittal tilt models. Furthermore, in the sagittal tilt models, in which the quadriceps atrophy was simulated, the loadings at 30° and 60° knee flexion were higher than in the physiological ones. Sagittal malalignment of the patellofemoral joint is a new concept that results in different loading patterns in the patellofemoral joint biomechanics. This malalignment in sagittal plane leads to increased loading values on the patellofemoral joint at 30° and 60° of the knee flexions. This new concept should be kept in mind during the course of diagnosis and treatment in patients with anterior knee pain. Definition of the exact biomechanical effects of the sagittal tilting will lead to the development of new treatment modalities.

  1. Comparison of neuromuscular and quadriceps strengthening exercise in the treatment of varus malaligned knees with medial knee osteoarthritis: a randomised controlled trial protocol.

    PubMed

    Bennell, Kim L; Egerton, Thorlene; Wrigley, Tim V; Hodges, Paul W; Hunt, Michael; Roos, Ewa M; Kyriakides, Mary; Metcalf, Ben; Forbes, Andrew; Ageberg, Eva; Hinman, Rana S

    2011-12-05

    Osteoarthritis of the knee involving predominantly the medial tibiofemoral compartment is common in older people, giving rise to pain and loss of function. Many people experience progressive worsening of the disease over time, particularly those with varus malalignment and increased medial knee joint load. Therefore, interventions that can reduce excessive medial knee loading may be beneficial in reducing the risk of structural progression. Traditional quadriceps strengthening can improve pain and function in people with knee osteoarthritis but does not appear to reduce medial knee load. A neuromuscular exercise program, emphasising optimal alignment of the trunk and lower limb joints relative to one another, as well as quality of movement performance, while dynamically and functionally strengthening the lower limb muscles, may be able to reduce medial knee load. Such a program may also be superior to traditional quadriceps strengthening with respect to improved pain and physical function because of the functional and dynamic nature. This randomised controlled trial will investigate the effect of a neuromuscular exercise program on medial knee joint loading, pain and function in individuals with medial knee joint osteoarthritis. We hypothesise that the neuromuscular program will reduce medial knee load as well as pain and functional limitations to a greater extent than a traditional quadriceps strengthening program. 100 people with medial knee pain, radiographic medial compartment osteoarthritis and varus malalignment will be recruited and randomly allocated to one of two 12-week exercise programs: quadriceps strengthening or neuromuscular exercise. Each program will involve 14 supervised exercise sessions with a physiotherapist plus four unsupervised sessions per week at home. The primary outcomes are medial knee load during walking (the peak external knee adduction moment from 3D gait analysis), pain, and self-reported physical function measured at baseline and immediately following the program. Secondary outcomes include the external knee adduction moment angular impulse, electromyographic muscle activation patterns, knee and hip muscle strength, balance, functional ability, and quality-of-life. The findings will help determine whether neuromuscular exercise is superior to traditional quadriceps strengthening regarding effects on knee load, pain and physical function in people with medial knee osteoarthritis and varus malalignment. Australian New Zealand Clinical Trials Registry reference: ACTRN12610000660088.

  2. Comparison of neuromuscular and quadriceps strengthening exercise in the treatment of varus malaligned knees with medial knee osteoarthritis: a randomised controlled trial protocol

    PubMed Central

    2011-01-01

    Background Osteoarthritis of the knee involving predominantly the medial tibiofemoral compartment is common in older people, giving rise to pain and loss of function. Many people experience progressive worsening of the disease over time, particularly those with varus malalignment and increased medial knee joint load. Therefore, interventions that can reduce excessive medial knee loading may be beneficial in reducing the risk of structural progression. Traditional quadriceps strengthening can improve pain and function in people with knee osteoarthritis but does not appear to reduce medial knee load. A neuromuscular exercise program, emphasising optimal alignment of the trunk and lower limb joints relative to one another, as well as quality of movement performance, while dynamically and functionally strengthening the lower limb muscles, may be able to reduce medial knee load. Such a program may also be superior to traditional quadriceps strengthening with respect to improved pain and physical function because of the functional and dynamic nature. This randomised controlled trial will investigate the effect of a neuromuscular exercise program on medial knee joint loading, pain and function in individuals with medial knee joint osteoarthritis. We hypothesise that the neuromuscular program will reduce medial knee load as well as pain and functional limitations to a greater extent than a traditional quadriceps strengthening program. Methods/Design 100 people with medial knee pain, radiographic medial compartment osteoarthritis and varus malalignment will be recruited and randomly allocated to one of two 12-week exercise programs: quadriceps strengthening or neuromuscular exercise. Each program will involve 14 supervised exercise sessions with a physiotherapist plus four unsupervised sessions per week at home. The primary outcomes are medial knee load during walking (the peak external knee adduction moment from 3D gait analysis), pain, and self-reported physical function measured at baseline and immediately following the program. Secondary outcomes include the external knee adduction moment angular impulse, electromyographic muscle activation patterns, knee and hip muscle strength, balance, functional ability, and quality-of-life. Discussion The findings will help determine whether neuromuscular exercise is superior to traditional quadriceps strengthening regarding effects on knee load, pain and physical function in people with medial knee osteoarthritis and varus malalignment. Trial Registration Australian New Zealand Clinical Trials Registry reference: ACTRN12610000660088 PMID:22141334

  3. Three-dimensional dynamic analysis of knee joint during gait in medial knee osteoarthritis using loading axis of knee.

    PubMed

    Nishino, Katsutoshi; Omori, Go; Koga, Yoshio; Kobayashi, Koichi; Sakamoto, Makoto; Tanabe, Yuji; Tanaka, Masaei; Arakawa, Masaaki

    2015-07-01

    We recently developed a new method for three-dimensional evaluation of mechanical factors affecting knee joint in order to help identify factors that contribute to the progression of knee osteoarthritis (KOA). This study aimed to verify the clinical validity of our method by evaluating knee joint dynamics during gait. Subjects were 41 individuals (14 normal knees; 8 mild KOAs; 19 severe KOAs). The positions of skin markers attached to the body were captured during gait, and bi-planar X-ray images of the lower extremities were obtained in standing position. The positional relationship between the markers and femorotibial bones was determined from the X-ray images. Combining this relationship with gait capture allowed for the estimation of relative movement between femorotibial bones. We also calculated the point of intersection of loading axis of knee on the tibial proximal surface (LAK point) to analyze knee joint dynamics. Knee flexion range in subjects with severe KOA during gait was significantly smaller than that in those with normal knees (p=0.011), and knee adduction in those with severe KOA was significantly larger than in those with mild KOA (p<0.000). LAK point was locally loaded on the medial compartment of the tibial surface as KOA progressed, with LAK point of subjects with severe KOA rapidly shifting medially during loading response. Local loading and medial shear force were applied to the tibial surface during stance phase as medial KOA progressed. Our findings suggest that our method is useful for the quantitative evaluation of mechanical factors that affect KOA progression. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Changes in knee joint load indices from before to 12 months after arthroscopic partial meniscectomy: a prospective cohort study.

    PubMed

    Thorlund, J B; Holsgaard-Larsen, A; Creaby, M W; Jørgensen, G M; Nissen, N; Englund, M; Lohmander, L S

    2016-07-01

    Patients undergoing arthroscopic partial meniscectomy (APM) are at increased risk of knee osteoarthritis (OA). Meniscal damage and/or surgery may alter knee joint loading to increase OA risk. We investigated changes in knee joint loading following medial APM surgery, compared with the contra-lateral leg. We estimated indices of knee joint loading (external peak knee adduction moment (KAM), KAM impulse and peak knee flexion moment (KFM)) normalized to body size (i.e., body mass (BM) and height (HT)) using 3D gait analysis in 23 patients (17 men, mean (SD) 46.2 (6.4) years, BMI 25.8 (3.4) kg/m(2)) without radiographic knee OA before and 12 months after medial APM. Static alignment was assessed by radiography and self-reported outcomes by Knee injury and Osteoarthritis Outcome Score (KOOS). Peak KAM and KAM impulse increased in the APM leg compared to the contra-lateral leg from before to 12 months after surgery (change difference: 0.38 Nm/BM*HT% 95% CI 0.01 to 0.76 (P = 0.049) and 0.20 Nm*s/BM*HT% 95% CI 0.10 to 0.30 (P < 0.001)). Patients self-reported improvements on all KOOS subscales (KOOS pain improvement: 22.8 95% CI 14.5 to 31.0 (P < 0.01)). A relative increase in indices of medial compartment loading was observed in the leg undergoing APM compared with the contra-lateral leg from before to 12 months after surgery. This increase may contribute to the elevated risk of knee OA in these patients. Randomized trials including a non-surgical control group are needed to determine if changes in joint loading following APM are caused by surgery or by changes in symptoms. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  5. Medial knee joint contact force in the intact limb during walking in recently ambulatory service members with unilateral limb loss: a cross-sectional study

    PubMed Central

    Krupenevich, Rebecca L.; Pruziner, Alison L.; Wolf, Erik J.; Schnall, Barri L.

    2017-01-01

    Background Individuals with unilateral lower limb amputation have a high risk of developing knee osteoarthritis (OA) in their intact limb as they age. This risk may be related to joint loading experienced earlier in life. We hypothesized that loading during walking would be greater in the intact limb of young US military service members with limb loss than in controls with no limb loss. Methods Cross-sectional instrumented gait analysis at self-selected walking speeds with a limb loss group (N = 10, age 27 ± 5 years, 170 ± 36 days since last surgery) including five service members with transtibial limb loss and five with transfemoral limb loss, all walking independently with their first prosthesis for approximately two months. Controls (N = 10, age 30 ± 4 years) were service members with no overt demographical risk factors for knee OA. 3D inverse dynamics modeling was performed to calculate joint moments and medial knee joint contact forces (JCF) were calculated using a reduction-based musculoskeletal modeling method and expressed relative to body weight (BW). Results Peak JCF and maximum JCF loading rate were significantly greater in limb loss (184% BW, 2,469% BW/s) vs. controls (157% BW, 1,985% BW/s), with large effect sizes. Results were robust to probabilistic perturbations to the knee model parameters. Discussion Assuming these data are reflective of joint loading experienced in daily life, they support a “mechanical overloading” hypothesis for the risk of developing knee OA in the intact limb of limb loss subjects. Examination of the evolution of gait mechanics, joint loading, and joint health over time, as well as interventions to reduce load or strengthen the ability of the joint to withstand loads, is warranted. PMID:28168120

  6. Medial knee loading is altered in subjects with early osteoarthritis during gait but not during step-up-and-over task

    PubMed Central

    Wesseling, Mariska; Smith, Colin R.; Thelen, Darryl G.; Verschueren, Sabine; Jonkers, Ilse

    2017-01-01

    This study evaluates knee joint loading during gait and step-up-and-over tasks in control subjects, subjects with early knee OA and those with established knee OA. Thirty-seven subjects with varying degrees of medial compartment knee OA severity (eighteen with early OA and sixteen with established OA), and nineteen healthy controls performed gait and step-up-and-over tasks. Knee joint moments, contact forces (KCF), the magnitude of contact pressures and center of pressure (CoP) location were analyzed for the three groups for both activities using a multi-body knee model with articular cartilage contact, 14 ligaments, and six degrees of freedom tibiofemoral and patellofemoral joints. During gait, the first peak of the medial KCF was significantly higher for patients with early knee OA (p = 0.048) and established knee OA (p = 0.001) compared to control subjects. Furthermore, the medial contact pressure magnitudes and CoP location were significantly different in both groups of patients compared to controls. Knee rotation moments (KRMs) and external rotation angles were significantly higher during early stance in both patient groups (p < 0.0001) compared to controls. During step-up-and-over, there was a high variability between the participants and no significant differences in KCF were observed between the groups. Knee joint loading and kinematics were found to be altered in patients with early knee OA only during gait. This is an indication that an excessive medial KCF and altered loading location, observed in these patients, is a contributor to early progression of knee OA. PMID:29117248

  7. Force measurements in the medial meniscus posterior horn attachment: effects of anterior cruciate ligament removal.

    PubMed

    Markolf, Keith L; Jackson, Steven R; McAllister, David R

    2012-02-01

    Tears of the medial meniscus posterior horn attachment (PHA) occur clinically, and an anterior cruciate ligament (ACL)-deficient knee may be more vulnerable to this injury. The PHA forces from applied knee loadings will increase after removal of the ACL. Controlled laboratory study. A cap of bone containing the medial meniscus PHA was attached to a load cell that measured PHA tensile force. Posterior horn attachment forces were recorded before and after ACL removal during anteroposterior (AP) laxity testing at ±200 N and during passive knee extension tests with 5 N·m tibial torque and varus-valgus moment. Selected tests were also performed with 500 N joint load. For AP tests with no joint load, ACL removal increased laxity between 0° and 90° and increased PHA force generated by applied anterior tibial force between 30° and 90°. For AP tests with an intact ACL, application of joint load approximately doubled PHA forces. Anteroposterior testing of ACL-deficient knees was not possible with joint load because of bone cap failures from high PHA forces. Removal of the ACL during knee extension tests under joint load significantly increased PHA forces between 20° and 90° of flexion. For unloaded tests with applied tibial torque and varus-valgus moment, ACL removal had no significant effect on PHA forces. Applied anterior tibial force and external tibial torque were loading modes that produced relatively high PHA forces, presumably by impingement of the medial femoral condyle against the medial meniscus posterior horn rim. Under joint load, an ACL-deficient knee was particularly susceptible to PHA injury from applied anterior tibial force. Because tensile forces developed in the PHA are also borne by meniscus tissue near the attachment site, loading mechanisms that produce high PHA forces could also produce complete or partial radial tears near the posterior horn, a relatively common clinical observation.

  8. Effect of walking speed on lower extremity joint loading in graded ramp walking.

    PubMed

    Schwameder, Hermann; Lindenhofer, Elke; Müller, Erich

    2005-07-01

    Lower extremity joint loading during walking is strongly affected by the steepness of the slope and might cause pain and injuries in lower extremity joint structures. One feasible measure to reduce joint loading is the reduction of walking speed. Positive effects have been shown for level walking, but not for graded walking or hiking conditions. The aim of the study was to quantify the effect of walking speed (separated into the two components, step length and cadence) on the joint power of the hip, knee and ankle and to determine the knee joint forces in uphill and downhill walking. Ten participants walked up and down a ramp with step lengths of 0.46, 0.575 and 0.69 m and cadences of 80, 100 and 120 steps per minute. The ramp was equipped with a force platform and the locomotion was filmed with a 60 Hz video camera. Loading of the lower extremity joints was determined using inverse dynamics. A two-dimensional knee model was used to calculate forces in the knee structures during the stance phase. Walking speed affected lower extremity joint loading substantially and significantly. Change of step length caused much greater loading changes for all joints compared with change of cadence; the effects were more distinct in downhill than in uphill walking. The results indicate that lower extremity joint loading can be effectively controlled by varying step length and cadence during graded uphill and downhill walking. Hikers can avoid or reduce pain and injuries by reducing walking speed, particularly in downhill walking.

  9. Immediate effects of a new microprocessor-controlled prosthetic knee joint: a comparative biomechanical evaluation.

    PubMed

    Bellmann, Malte; Schmalz, Thomas; Ludwigs, Eva; Blumentritt, Siegmar

    2012-03-01

    To investigate the immediate biomechanical effects after transition to a new microprocessor-controlled prosthetic knee joint. Intervention cross-over study with repeated measures. Only prosthetic knee joints were changed. Motion analysis laboratory. Men (N=11; mean age ± SD, 36.7±10.2y; Medicare functional classification level, 3-4) with unilateral transfemoral amputation. Two microprocessor-controlled prosthetic knee joints: C-Leg and a new prosthetic knee joint, Genium. Static prosthetic alignment, time-distance parameters, kinematic and kinetic parameters, and center of pressure. After a half-day training and an additional half-day accommodation, improved biomechanical outcomes were demonstrated by the Genium: lower ground reaction forces at weight acceptance during level walking at various velocities, increased swing phase flexion angles during walking on a ramp, and level walking with small steps. Maximum knee flexion angle during swing phase at various velocities was nearly equal for Genium. Step-over-step stair ascent with the Genium knee was more physiologic as demonstrated by a more equal load distribution between the prosthetic and contralateral sides and a more natural gait pattern. When descending stairs and ramps, knee flexion moments with the Genium tended to increase. During quiet stance on a decline, subjects using Genium accepted higher loading of the prosthetic side knee joint, thus reducing same side hip joint loading as well as postural sway. In comparision to the C-Leg, the Genium demonstrated immediate biomechanical advantages during various daily ambulatory activities, which may lead to an increase in range and diversity of activity of people with above-knee amputations. Results showed that use of the Genium facilitated more natural gait biomechanics and load distribution throughout the affected and sound musculoskeletal structure. This was observed during quiet stance on a decline, walking on level ground, and walking up and down ramps and stairs. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  10. Musculoskeletal multibody dynamics simulation of the contact mechanics and kinematics of a natural knee joint during a walking cycle.

    PubMed

    Hu, Jiayu; Chen, Zhenxian; Xin, Hua; Zhang, Qida; Jin, Zhongmin

    2018-05-01

    Detailed knowledge of the in vivo loading and kinematics in the knee joint is essential to understand its normal functions and the aetiology of osteoarthritis. Computer models provide a viable non-invasive solution for estimating joint loading and kinematics during different physiological activities. However, the joint loading and kinematics of the tibiofemoral and patellofemoral joints during a gait cycle were not typically investigated concurrently in previous computational simulations. In this study, a natural knee architecture was incorporated into a lower extremity musculoskeletal multibody dynamics model based on a force-dependent kinematics approach to investigate the contact mechanics and kinematics of a natural knee joint during a walking cycle. Specifically, the contact forces between the femoral/tibial articular cartilages and menisci and between the femoral and tibial/patellar articular cartilages were quantified. The contact forces and kinematics of the tibiofemoral and patellofemoral joints and the muscle activations and ligament forces were predicted simultaneously with a reasonable level of accuracy. The developed musculoskeletal multibody dynamics model with a natural knee architecture can serve as a potential platform for assisting clinical decision-making and postoperative rehabilitation planning.

  11. Early Response of Mouse Joint Tissues to Noninvasive Knee Injury Suggests Treatment Targets

    PubMed Central

    Wu, P.; Holguin, N.; Silva, M. J.; Fu, M.; Liao, W.; Sandell, L. J.

    2015-01-01

    Objective Joint trauma can lead to a spectrum of acute lesions, including cartilage degradation, ligament or meniscus tears, and synovitis, all potentially associated with osteoarthritis. The goal of this study was to generate and validate a murine model of knee joint trauma following non-invasive controlled injurious compression in vivo and to investigate early molecular events. Methods The right knees of 8-week old mice were placed in a hyperflexed position and subjected to compressive joint loading at one of three peak forces (3, 6, 9 N) for 60 cycles in a single loading period and harvested at 5, 9 and 14 days post loading (n=3–5 mice for each time point and for each loading). The left knees were not loaded and served as the contralateral controls. Histological, immunohistochemical and ELISA analyses were performed to evaluate acute pathologic features in chondrocyte viability, cartilage matrix metabolism, synovial reaction, and serum COMP levels. Results Acute joint pathology was associated with increased injurious loads. All loading regimens induced chondrocyte apoptosis, cartilage matrix degradation, disruption of cartilage collagen fibril arrangement, and increased levels of serum COMP. We also observed that 6N loading induced mild synovitis by day 5 whereas at 9 N, with tearing of the anterior cruciate ligament, severe posttraumatic synovitis and ectopic cartilage formation were observed. Conclusion We have established and analyzed some early events in a murine model of knee joint trauma with different degrees of over-loading in vivo. These results suggest that immediate therapies particularly targeted to apoptosis and synovial cell proliferation could affect the acute posttraumatic reaction to potentially limit chronic consequences and osteoarthritis. PMID:24470303

  12. Multi-Axis Prosthetic Knee Resembles Alpine Skiing Movements of an Intact Leg

    PubMed Central

    Demšar, Ivan; Duhovnik, Jože; Lešnik, Blaž; Supej, Matej

    2015-01-01

    The purpose of the study was to analyse the flexion angles of the ski boot, ankle and knee joints of an above-knee prosthesis and to compare them with an intact leg and a control group of skiers. One subject with an above-knee amputation of the right leg and eight healthy subjects simulated the movement of a skiing turn by performing two-leg squats in laboratory conditions. By adding additional loads in proportion to body weight (BW; +1/3 BW, +2/3 BW, +3/3 BW), various skiing regimes were simulated. Change of Flexion Angle (CoFA) and Range of Motion (RoM) in the ski boot, ankle and knee joints were calculated and compared. An average RoM in the skiing boot on the side of prosthesis (4.4 ± 1.1°) was significantly lower compared to an intact leg (5.9 ± 1.8°) and the control group (6.5 ± 2.3°). In the ankle joint, the average RoM was determined to be 13.2±2.9° in the prosthesis, 12.7 ± 2.8° in an intact leg and 14.8±3.6 in the control group. However, the RoM of the knee joint in the prosthesis (42.2 ± 4.2°) was significantly larger than that of the intact leg (34.7 ± 4.4°). The average RoM of the knee joint in the control group was 47.8 ± 5.4°. The influences of additional loads on the kinematics of the lower extremities were different on the side of the prosthesis and on the intact leg. In contrast, additional loads did not produce any significant differences in the control group. Although different CoFAs in the ski boot, ankle and knee joints were used, an above-knee prosthesis with a built-in multi-axis prosthetic knee enables comparable leg kinematics in simulated alpine skiing. Key points The RoM in the ski boot on the side of the prosthetic leg was smaller than the RoM of the intact leg and the control group of healthy subjects. The RoM in the ankle joint of prosthetic leg was comparable to that of the intact leg and the control group of healthy subjects. The RoM in the prosthetic knee joint was greater than the RoM in the knee joint of the intact leg and smaller than that of the control group. The total knee flexions in the laboratory measurements were comparable with field measurements. Additional load affects the RoM of the ski boot, ankle and knee joints for the amputated skier in both legs. No significant influence from the additional load was found on the RoM in the control group of healthy subjects. The above-knee prosthesis with a multiple-axis prosthetic knee reproduces the alpine skiing kinematics of an intact leg. PMID:26664282

  13. Computational Knee Ligament Modeling Using Experimentally Determined Zero-Load Lengths

    PubMed Central

    Bloemker, Katherine H; Guess, Trent M; Maletsky, Lorin; Dodd, Kevin

    2012-01-01

    This study presents a subject-specific method of determining the zero-load lengths of the cruciate and collateral ligaments in computational knee modeling. Three cadaver knees were tested in a dynamic knee simulator. The cadaver knees also underwent manual envelope of motion testing to find their passive range of motion in order to determine the zero-load lengths for each ligament bundle. Computational multibody knee models were created for each knee and model kinematics were compared to experimental kinematics for a simulated walk cycle. One-dimensional non-linear spring damper elements were used to represent cruciate and collateral ligament bundles in the knee models. This study found that knee kinematics were highly sensitive to altering of the zero-load length. The results also suggest optimal methods for defining each of the ligament bundle zero-load lengths, regardless of the subject. These results verify the importance of the zero-load length when modeling the knee joint and verify that manual envelope of motion measurements can be used to determine the passive range of motion of the knee joint. It is also believed that the method described here for determining zero-load length can be used for in vitro or in vivo subject-specific computational models. PMID:22523522

  14. Angular-velocity control approach for stance-control orthoses.

    PubMed

    Lemaire, Edward D; Goudreau, Louis; Yakimovich, Terris; Kofman, Jonathan

    2009-10-01

    Currently, stance-control knee orthoses require external control mechanisms to control knee flexion during stance and allow free knee motion during the swing phase of gait. A new angular-velocity control approach that uses a rotary-hydraulic device to resist knee flexion when the knee angular velocity passes a preset threshold is presented. This angular-velocity approach for orthotic stance control is based on the premise that knee-flexion angular velocity during a knee-collapse event, such as a stumble or fall, is greater than that during walking. The new hydraulic knee-flexion control device does not require an external control mechanism to switch from free motion to stance control mode. Functional test results demonstrated that the hydraulic angular-velocity activated knee joint provided free knee motion during walking, engaged upon knee collapse, and supported body weight while the end-user recovered to a safe body position. The joint was tested to 51.6 Nm in single loading tests and passed 200,000 repeated loading cycles with a peak load of 88 Nm per cycle. The hydraulic, angular velocity activation approach has potential to improve safety and security for people with lower extremity weakness or when recovering from joint trauma.

  15. The influence of minimalist footwear and stride length reduction on lower-extremity running mechanics and cumulative loading.

    PubMed

    Firminger, Colin R; Edwards, W Brent

    2016-12-01

    To examine the effects of shoe type and stride length reduction on lower-extremity running mechanics and cumulative loading. Within-subject with four conditions: (1) control shoe at preferred stride length; (2) control shoe at 90% preferred stride length; (3) minimalist shoe at preferred stride length; (4) minimalist shoe at 90% preferred stride length. Fourteen young healthy males ran overground at their preferred speed while motion capture, force platform, and plantar pressure data were collected. Peak moments, impulse, mechanical work, and cumulative impulse were calculated at the metatarsophalangeal, ankle, and knee joint, and compared between conditions using a 2×2 factor repeated measures ANOVA. In general, running in minimalist footwear increased measures of loading at the metatarsophalangeal joint and ankle joint (mean increases of 7.3% and 5.9%, respectively), but decreased measures of loading at the knee (mean decrease of 7.3%). Conversely, running with reduced stride length decreased single-stance measures of loading at the ankle and knee joint (ranging from -0.9% to -20.5%), though cumulative impulse was higher at the ankle and lower at the knee. Running in minimalist shoes increased loads at the metatarsophalangeal and ankle joint, which may explain some of the incidence of overuse injuries observed in minimalist shoe users. Decreased ankle loads at 90% preferred stride length were not necessarily sufficient to reduce cumulative loads when impulse and loading cycles were weighted equally. Knee loads decreased more when running at 90% preferred stride length (16.2% mean reduction) versus running in a minimalist shoe (7.3% mean reduction), but both load reduction mechanisms appeared to have an additive effect (22.2% mean reduction). Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  16. Effect of repeated passive anterior loading on human knee anterior laxity.

    PubMed

    Vauhnik, Renata; Perme, Maja Pohar; Barcellona, Massimo G; Morrissey, Matthew C; Sevšek, France; Rugelj, Darja

    2015-10-01

    Increased knee anterior laxity results when the anterior cruciate ligament is injured. This increased laxity can cause knee dysfunction. Until recently this laxity was believed to be only diminished through surgery. But recent findings indicate that knee anterior laxity may be decreased with repeated loading of the knee. The purpose of this study was to test the hypothesis that regular passive anterior loading of the uninjured human knee would enhance its stiffness. Randomized controlled trial. Knee anterior laxity was tested using an arthrometer in 22 young, uninjured females before, during and after a 3 month period during which passive anterior loading was applied by a trained physiotherapist over 5 sessions per week to a randomly assigned knee. Knee anterior laxity was not affected by the passive anterior loading of the knee. Given that in this study repeated passive loading of the knee did not change knee anterior laxity, it would be easy to conclude that this training is ineffective and no further research is required. We caution against this given the relatively short duration and possibly insufficient intensity of the training and the population studied; individuals with normal joint laxity. We recommend that future research be performed that consists of individuals with lax joints who receive training for prolonged periods. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Differences in knee joint kinematics and forces after posterior cruciate retaining and stabilized total knee arthroplasty.

    PubMed

    Wünschel, Markus; Leasure, Jeremi M; Dalheimer, Philipp; Kraft, Nicole; Wülker, Nikolaus; Müller, Otto

    2013-12-01

    Posterior cruciate ligament (PCL) retaining (CR) and -sacrificing (PS) total knee arthroplasties (TKA) are widely-used to treat osteoarthritis of the knee joint. The PS design substitutes the function of the PCL with a cam-spine mechanism which may produce adverse changes to joint kinematics and kinetics. CR- and PS-TKA were performed on 11 human knee specimens. Joint kinematics were measured with a dynamic knee simulator and motion tracking equipment. In-situ loads of the PCL and cam-spine were measured with a robotic force sensor system. Partial weight bearing flexions were simulated and external forces were applied. The PS-TKA rotated significantly less throughout the whole flexion range compared to the CR-TKA. Femoral roll back was greater in the PS-TKA; however, this was not correlated with lower quadriceps forces. Application of external loads produced significantly different in-situ force profiles between the TKA systems. Our data demonstrate that the PS-design significantly alters kinematics of the knee joint. Our data also suggest the cam-spine mechanism may have little influence on high flexion kinematics (such as femoral rollback) with most of the load burden shared by supporting implant and soft-tissue structures. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. The Influence of Joint Loading on Bone Marrow Lesions in the Knee: A Systematic Review With Meta-analysis.

    PubMed

    Beckwée, David; Vaes, Peter; Shahabpour, Maryam; Muyldermans, Ronald; Rommers, Nikki; Bautmans, Ivan

    2015-12-01

    Bone marrow lesions (BMLs) are considered as predictors of pain, disability, and structural progression of knee osteoarthritis. The relationship between knee loading and BMLs is not yet completely understood. To summarize the available evidence regarding the relationship between joint loading and the prevalence and progression of BMLs in the tibiofemoral joint. Meta-analysis. Three databases (PubMed, Web of Science, and The Cochrane Library) were systematically screened for studies encompassing BMLs and changes in knee loading. A methodological quality assessment was conducted, and a meta-analysis computing overall odds ratios (ORs) was performed where possible. A total of 29 studies involving 7641 participants were included. Mechanical loading was categorized as body weight and composition, compartmental load, structural lesion, and physical activity. High compartmental loads and structural lesions increased the risk for BMLs (overall ORs ranging from 1.56 [95% CI, 1.13-2.15] to 8.2 [95% CI, 4.4-15.1]; P = .006). Body weight increased the risk for BMLs to a lesser extent (overall OR, 1.03; 95% CI, 1.01-1.05; P = .007). Contradictory results for the effect of physical activity on BMLs were found. Augmented compartmental loads and structural lesions increased the risk of the presence or progression of BMLs. Body weight increased the risk for BMLs to a lesser extent. Contradictory results for the effect of physical activity on BMLs may be explained by a dose-response relationship, knee alignment, and structural lesions. It has been shown that unloading the knee temporarily may induce beneficial effects on osteoarthritis-related structural changes. Therefore, an early recognition of BMLs in the aging athlete's knee may provide information to counter the onset and aggravation of symptomatic knee osteoarthritis by reducing the knee load. © 2015 The Author(s).

  19. Relationships between in vivo dynamic knee joint loading, static alignment and tibial subchondral bone microarchitecture in end-stage knee osteoarthritis.

    PubMed

    Roberts, B C; Solomon, L B; Mercer, G; Reynolds, K J; Thewlis, D; Perilli, E

    2018-04-01

    To study, in end-stage knee osteoarthritis (OA) patients, relationships between indices of in vivo dynamic knee joint loads obtained pre-operatively using gait analysis, static knee alignment, and the subchondral trabecular bone (STB) microarchitecture of their excised tibial plateau quantified with 3D micro-CT. Twenty-five knee OA patients scheduled for total knee arthroplasty underwent pre-operative gait analysis. Mechanical axis deviation (MAD) was determined radiographically. Following surgery, excised tibial plateaus were micro-CT-scanned and STB microarchitecture analysed in four subregions (anteromedial, posteromedial, anterolateral, posterolateral). Regional differences in STB microarchitecture and relationships between joint loading and microarchitecture were examined. STB microarchitecture differed among subregions (P < 0.001), anteromedially exhibiting highest bone volume fraction (BV/TV) and lowest structure model index (SMI). Anteromedial BV/TV and SMI correlated strongest with the peak external rotation moment (ERM; r = -0.74, r = 0.67, P < 0.01), despite ERM being the lowest (by factor of 10) of the moments considered, with majority of ERM measures below accuracy thresholds; medial-to-lateral BV/TV ratios correlated with ERM, MAD, knee adduction moment (KAM) and internal rotation moment (|r|-range: 0.54-0.74). When controlling for walking speed, KAM and MAD, the ERM explained additional 11-30% of the variations in anteromedial BV/TV and medial-to-lateral BV/TV ratio (R 2  = 0.59, R 2  = 0.69, P < 0.01). This preliminary study suggests significant associations between tibial plateau STB microarchitecture and knee joint loading indices in end-stage knee OA patients. Particularly, anteromedial BV/TV correlates strongest with ERM, whereas medial-to-lateral BV/TV ratio correlates strongest with indicators of medial-to-lateral joint loading (MAD, KAM) and rotational moments. However, associations with ERM should be interpreted with caution. Copyright © 2018 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  20. Acetabular cartilage defects cause altered hip and knee joint coordination variability during gait.

    PubMed

    Samaan, Michael A; Teng, Hsiang-Ling; Kumar, Deepak; Lee, Sonia; Link, Thomas M; Majumdar, Sharmila; Souza, Richard B

    2015-12-01

    Patients with acetabular cartilage defects reported increased pain and disability compared to those without acetabular cartilage defects. The specific effects of acetabular cartilage defects on lower extremity coordination patterns are unclear. The purpose of this study was to determine hip and knee joint coordination variability during gait in those with and without acetabular cartilage defects. A combined approach, consisting of a semi-quantitative MRI-based quantification method and vector coding, was used to assess hip and knee joint coordination variability during gait in those with and without acetabular cartilage lesions. The coordination variability of the hip flexion-extension/knee rotation, hip abduction-adduction/knee rotation, and hip rotation/knee rotation joint couplings were reduced in the acetabular lesion group compared to the control group during loading response of the gait cycle. The lesion group demonstrated increased variability in the hip flexion-extension/knee rotation and hip abduction-adduction/knee rotation joint couplings, compared to the control group, during the terminal stance/pre-swing phase of gait. Reduced variability during loading response in the lesion group may suggest reduced movement strategies and a possible compensation mechanism for lower extremity instability during this phase of the gait cycle. During terminal stance/pre-swing, a larger variability in the lesion group may suggest increased movement strategies and represent a compensation or pain avoidance mechanism caused by the load applied to the hip joint. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Does aquatic exercise reduce hip and knee joint loading? In vivo load measurements with instrumented implants

    PubMed Central

    Kutzner, Ines; Dymke, Jörn; Damm, Philipp; Duda, Georg N.; Günzl, Reiner; Bergmann, Georg

    2017-01-01

    Aquatic exercises are widely used for rehabilitation or preventive therapies in order to enable mobilization and muscle strengthening while minimizing joint loading of the lower limb. The load reducing effect of water due to buoyancy is a main advantage compared to exercises on land. However, also drag forces have to be considered that act opposite to the relative motion of the body segments and require higher muscle activity. Due to these opposing effects on joint loading, the load-reducing effect during aquatic exercises remains unknown. The aim of this study was to quantify the joint loads during various aquatic exercises and to determine the load reducing effect of water. Instrumented knee and hip implants with telemetric data transfer were used to measure the resultant joint contact forces in 12 elderly subjects (6x hip, 6x knee) in vivo. Different dynamic, weight-bearing and non-weight-bearing activities were performed by the subjects on land and in chest-high water. Non-weight-bearing hip and knee flexion/extension was performed at different velocities and with additional Aquafins. Joint forces during aquatic exercises ranged between 32 and 396% body weight (BW). Highest forces occurred during dynamic activities, followed by weight-bearing and slow non-weight-bearing activities. Compared to the same activities on land, joint forces were reduced by 36–55% in water with absolute reductions being greater than 100%BW during weight-bearing and dynamic activities. During non-weight-bearing activities, high movement velocities and additional Aquafins increased the joint forces by up to 59% and resulted in joint forces of up to 301%BW. This study confirms the load reducing effect of water during weight-bearing and dynamic exercises. Nevertheless, high drag forces result in increased joint contact forces and indicate greater muscle activity. By the choice of activity, movement velocity and additional resistive devices joint forces can be modulated individually in the course of rehabilitation or preventive therapies. PMID:28319145

  2. Does aquatic exercise reduce hip and knee joint loading? In vivo load measurements with instrumented implants.

    PubMed

    Kutzner, Ines; Richter, Anja; Gordt, Katharina; Dymke, Jörn; Damm, Philipp; Duda, Georg N; Günzl, Reiner; Bergmann, Georg

    2017-01-01

    Aquatic exercises are widely used for rehabilitation or preventive therapies in order to enable mobilization and muscle strengthening while minimizing joint loading of the lower limb. The load reducing effect of water due to buoyancy is a main advantage compared to exercises on land. However, also drag forces have to be considered that act opposite to the relative motion of the body segments and require higher muscle activity. Due to these opposing effects on joint loading, the load-reducing effect during aquatic exercises remains unknown. The aim of this study was to quantify the joint loads during various aquatic exercises and to determine the load reducing effect of water. Instrumented knee and hip implants with telemetric data transfer were used to measure the resultant joint contact forces in 12 elderly subjects (6x hip, 6x knee) in vivo. Different dynamic, weight-bearing and non-weight-bearing activities were performed by the subjects on land and in chest-high water. Non-weight-bearing hip and knee flexion/extension was performed at different velocities and with additional Aquafins. Joint forces during aquatic exercises ranged between 32 and 396% body weight (BW). Highest forces occurred during dynamic activities, followed by weight-bearing and slow non-weight-bearing activities. Compared to the same activities on land, joint forces were reduced by 36-55% in water with absolute reductions being greater than 100%BW during weight-bearing and dynamic activities. During non-weight-bearing activities, high movement velocities and additional Aquafins increased the joint forces by up to 59% and resulted in joint forces of up to 301%BW. This study confirms the load reducing effect of water during weight-bearing and dynamic exercises. Nevertheless, high drag forces result in increased joint contact forces and indicate greater muscle activity. By the choice of activity, movement velocity and additional resistive devices joint forces can be modulated individually in the course of rehabilitation or preventive therapies.

  3. The relationships between instrumented measurements of ankle and knee ligamentous laxity and generalized joint laxity.

    PubMed

    Pearsall, A W; Kovaleski, J E; Heitman, R J; Gurchiek, L R; Hollis, J M

    2006-03-01

    The purpose of this study was to evaluate whether lower extremity joint laxity is a function of a particular joint and/or a generalizable characteristic (trait) of the person. Validated instrumented measurements of ankle and knee joint-specific laxity in the same individual were correlated to determine whether a relationship exists. In addition, ankle and knee joint-specific laxity were correlated with generalized joint laxity using the modified Beighton mobility index. Fifty-seven male and female athletes were studied. We examined dominant ankle laxity using an ankle arthrometer and dominate knee anterior laxity using the KT 2000. The dominant ankle was loaded in anteroposterior (AP) drawer and inversion-eversion (I-E) rotation. Laxity was measured as total AP displacement (millimeters) after +/-125 N of applied force and total I-E rotation (degrees) was measured after +/-4 N x m of applied torque. The dominant knee was loaded with an anterior drawer and laxity (millimeters) was measured after manual maximum displacement. Non-significant correlations were observed among the test variables for generalized joint laxity (0.21 to 0.37; P>0.05) and instrumented ankle and knee joint laxity (0.19 to 0.21; P>0.05). When examined by gender, no statistically significant correlations (0.05 to 0.40; P>0.05) were found for either generalized laxity or instrumented ankle and knee joint laxity. These results imply that ankle and knee joint laxity are joint-specific and not generalizable.

  4. The relationship between pain and dynamic knee joint loading in knee osteoarthritis varies with radiographic disease severity. A cross sectional study.

    PubMed

    Henriksen, Marius; Aaboe, Jens; Bliddal, Henning

    2012-08-01

    In a cross sectional study, we investigated the relationships between knee pain and mechanical loading across the knee, as indicated by the external knee adduction moment (KAM) during walking in patients with symptomatic knee OA who were distinguished by different radiographic disease severities. Data from 137 symptomatic medial knee OA patients were used. Based on Kellgren/Lawrence (K/L) grading, the patients were divided into radiographically less severe (K/L ≤ 2, n=68) or severe (K/L>2, n=69) medial knee OA. Overall knee pain was rated on a 10 cm visual analog scale, and peak KAM and KAM impulses were obtained from gait analyses. Mixed linear regression analyses were performed with KAM variables as the outcome, and pain and disease severity as independent variables, adjusting for age, gender, and walking speed. In adjusted analyses, less severe patients demonstrated negative relationships between pain intensities and dynamic loading. The severe patient group showed no relationship between pain intensity and peak KAM, and a positive relationship between pain intensity and KAM impulse. In radiographically less severe knee OA, the negative relationships between pain intensity and dynamic knee joint loading indicate a natural reaction to pain, which will limit the stress on the joint. In contrast, either absent or positive relationships between pain and dynamic loading in severe OA may lead to overuse and accelerated disease progression. These findings may have a large potential interest for strategies of treatment in knee OA. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Tibiofemoral loss of contact area but no changes in peak pressures after meniscectomy in a Lapine in vivo quadriceps force transfer model.

    PubMed

    Leumann, Andre; Fortuna, Rafael; Leonard, Tim; Valderrabano, Victor; Herzog, Walter

    2015-01-01

    The menisci are thought to modulate load transfer and to absorb shocks in the knee joint. No study has experimentally measured the meniscal functions in the intact, in vivo joint loaded by physiologically relevant muscular contractions. Right knee joints of seven New Zealand white rabbits were loaded using isometric contractions of the quadriceps femoris muscles controlled by femoral nerve stimulation. Isometric knee extensor torques at the maximal and two submaximal force levels were performed at knee angles of 70°, 90°, 110°, and 130°. Patellofemoral and tibiofemoral contact areas and pressure distributions were measured using Fuji Presensor film inserted above and below the menisci and also with the menisci removed. Meniscectomy was associated with a decrease in tibiofemoral contact area ranging from 30 to 70% and a corresponding increase in average contact pressures. Contact areas measured below the menisci were consistently larger than those measured on top of the menisci. Contact areas in the patellofemoral joint (PFJ), and peak pressures in tibiofemoral and PFJs, were not affected by meniscectomy. Contact areas and peak pressures in all joints depended crucially on knee joint angle and quadriceps force: The more flexed the knee joint was, the larger were the contact areas and the higher were the peak pressures. In agreement with the literature, removal of the menisci was associated with significant decreases in tibiofemoral contact area and corresponding increases in average contact pressures, but surprisingly, peak pressures remained unaffected, indicating that the function of the menisci is to distribute loads across a greater contact area.

  6. In vitro method for assessing the biomechanics of the patellofemoral joint following total knee arthroplasty.

    PubMed

    Coles, L G; Gheduzzi, S; Miles, A W

    2014-12-01

    The patellofemoral joint is a common site of pain and failure following total knee arthroplasty. A contributory factor may be adverse patellofemoral biomechanics. Cadaveric investigations are commonly used to assess the biomechanics of the joint, but are associated with high inter-specimen variability and often cannot be carried out at physiological levels of loading. This study aimed to evaluate the suitability of a novel knee simulator for investigating patellofemoral joint biomechanics. This simulator specifically facilitated the extended assessment of patellofemoral joint biomechanics under physiological levels of loading. The simulator allowed the knee to move in 6 degrees of freedom under quadriceps actuation and included a simulation of the action of the hamstrings. Prostheses were implanted on synthetic bones and key soft tissues were modelled with a synthetic analogue. In order to evaluate the physiological relevance and repeatability of the simulator, measurements were made of the quadriceps force and the force, contact area and pressure within the patellofemoral joint using load cells, pressure-sensitive film, and a flexible pressure sensor. The results were in agreement with those previously reported in the literature, confirming that the simulator is able to provide a realistic physiological loading situation. Under physiological loading, average standard deviations of force and area measurements were substantially lower and comparable to those reported in previous cadaveric studies, respectively. The simulator replicates the physiological environment and has been demonstrated to allow the initial investigation of factors affecting patellofemoral biomechanics following total knee arthroplasty. © IMechE 2014.

  7. Post-Traumatic Osteoarthritis in Mice Following Mechanical Injury to the Synovial Joint

    PubMed Central

    Rai, Muhammad Farooq; Duan, Xin; Quirk, James D.; Holguin, Nilsson; Schmidt, Eric J.; Chinzei, Nobuaki; Silva, Matthew J.; Sandell, Linda J.

    2017-01-01

    We investigated the spectrum of lesions characteristic of post-traumatic osteoarthritis (PTOA) across the knee joint in response to mechanical injury. We hypothesized that alteration in knee joint stability in mice reproduces molecular and structural features of PTOA that would suggest potential therapeutic targets in humans. The right knees of eight-week old male mice from two recombinant inbred lines (LGXSM-6 and LGXSM-33) were subjected to axial tibial compression. Three separate loading magnitudes were applied: 6N, 9N, and 12N. Left knees served as non-loaded controls. Mice were sacrificed at 5, 9, 14, 28, and 56 days post-loading and whole knee joint changes were assessed by histology, immunostaining, micro-CT, and magnetic resonance imaging. We observed that tibial compression disrupted joint stability by rupturing the anterior cruciate ligament (except for 6N) and instigated a cascade of temporal and topographical features of PTOA. These features included cartilage extracellular matrix loss without proteoglycan replacement, chondrocyte apoptosis at day 5, synovitis present at day 14, osteophytes, ectopic calcification, and meniscus pathology. These findings provide a plausible model and a whole-joint approach for how joint injury in humans leads to PTOA. Chondrocyte apoptosis, synovitis, and ectopic calcification appear to be targets for potential therapeutic intervention. PMID:28345597

  8. Intra-Articular Knee Contact Force Estimation During Walking Using Force-Reaction Elements and Subject-Specific Joint Model.

    PubMed

    Jung, Yihwan; Phan, Cong-Bo; Koo, Seungbum

    2016-02-01

    Joint contact forces measured with instrumented knee implants have not only revealed general patterns of joint loading but also showed individual variations that could be due to differences in anatomy and joint kinematics. Musculoskeletal human models for dynamic simulation have been utilized to understand body kinetics including joint moments, muscle tension, and knee contact forces. The objectives of this study were to develop a knee contact model which can predict knee contact forces using an inverse dynamics-based optimization solver and to investigate the effect of joint constraints on knee contact force prediction. A knee contact model was developed to include 32 reaction force elements on the surface of a tibial insert of a total knee replacement (TKR), which was embedded in a full-body musculoskeletal model. Various external measurements including motion data and external force data during walking trials of a subject with an instrumented knee implant were provided from the Sixth Grand Challenge Competition to Predict in vivo Knee Loads. Knee contact forces in the medial and lateral portions of the instrumented knee implant were also provided for the same walking trials. A knee contact model with a hinge joint and normal alignment could predict knee contact forces with root mean square errors (RMSEs) of 165 N and 288 N for the medial and lateral portions of the knee, respectively, and coefficients of determination (R2) of 0.70 and -0.63. When the degrees-of-freedom (DOF) of the knee and locations of leg markers were adjusted to account for the valgus lower-limb alignment of the subject, RMSE values improved to 144 N and 179 N, and R2 values improved to 0.77 and 0.37, respectively. The proposed knee contact model with subject-specific joint model could predict in vivo knee contact forces with reasonable accuracy. This model may contribute to the development and improvement of knee arthroplasty.

  9. The effect of instruction in analgesic use compared with neuromuscular exercise on knee-joint load in patients with knee osteoarthritis: a randomized, single-blind, controlled trial.

    PubMed

    Holsgaard-Larsen, A; Clausen, B; Søndergaard, J; Christensen, R; Andriacchi, T P; Roos, E M

    2017-04-01

    To investigate the effect of a neuro-muscular exercise (NEMEX) therapy program compared with instructions in optimized analgesics and anti-inflammatory drug use (PHARMA), on measures of knee-joint load in people with mild to moderate knee osteoarthritis (OA). We hypothesized that knee joint loading during walking would be reduced by NEMEX and potentially increased by PHARMA. Single-blind, randomized controlled trial (RCT) comparing NEMEX therapy twice a week with PHARMA. Participants with mild-to-moderate medial tibiofemoral knee OA were randomly allocated (1:1) to one of two 8-week treatments. Primary outcome was change in knee load during walking (Knee Index, a composite score from all three planes based on 3D movement analysis) after 8 weeks of intervention. Secondary outcomes were frontal plane peak knee adduction moment (KAM), Knee Injury and Osteoarthritis Outcome Scores (KOOS) and functional performance tests. Ninety three participants (57% women, 58 ± 8 years with a body mass index [BMI] of 27 ± 4 kg/m 2 (mean ± standard deviation [SD])) were randomized to NEMEX group (n = 47) or PHARMA (n = 46); data from 44 (94%) and 41 (89%) participants respectively, were available at follow-up. 49% of the participants in NEMEX and only 7% in PHARMA demonstrated good compliance. We found no difference in the primary outcome as evaluated by the Knee Index -0.07 [-0.17; 0.04] Nm/%BW HT. Secondary outcomes largely supported this finding. We found no difference in the primary outcome; knee joint load change during walking from a NEMEX program vs information on the recommended use of analgesics and anti-inflammatory drugs. ClinicalTrials.gov Identifier: NCT01638962 (July 3, 2012). Ethical Committee: S-20110153. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  10. Effects of load carriage and footwear on lower extremity kinetics and kinematics during overground walking.

    PubMed

    Dames, Kevin D; Smith, Jeremy D

    2016-10-01

    Kinetic and kinematic responses during walking vary by footwear condition. Load carriage also influences gait patterns, but it is unclear how an external load influences barefoot walking. Twelve healthy adults (5 women, 7 men) with no known gait abnormalities participated in this study (age=23±3years, height=1.73±0.11m, and mass=70.90±12.67kg). Ground reaction forces and 3D motion were simultaneously collected during overground walking at 1.5ms -1 in four conditions: Barefoot Unloaded, Shod Unloaded, Barefoot Loaded, and Shod Loaded. Barefoot walking reduced knee and hip joint ranges of motion, as well as stride length, stance time, swing time, and double support time. Load carriage increased stance and double support times. The 15% body weight load increased GRFs ∼15%. Walking barefoot reduced peak anteroposterior GRFs but not peak vertical GRFs. Load carriage increased hip, knee, and ankle joint moments and powers, while walking barefoot increased knee and hip moments and powers. Thus, spatiotemporal and kinematic adjustments to walking barefoot decrease GRFs but increase knee and hip kinetic measures during overground walking. The ankle seems to be less affected by these footwear conditions. Regardless of footwear, loading requires larger GRFs, joint loads, and joint powers. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Prediction of Knee Joint Contact Forces From External Measures Using Principal Component Prediction and Reconstruction.

    PubMed

    Saliba, Christopher M; Clouthier, Allison L; Brandon, Scott C E; Rainbow, Michael J; Deluzio, Kevin J

    2018-05-29

    Abnormal loading of the knee joint contributes to the pathogenesis of knee osteoarthritis. Gait retraining is a non-invasive intervention that aims to reduce knee loads by providing audible, visual, or haptic feedback of gait parameters. The computational expense of joint contact force prediction has limited real-time feedback to surrogate measures of the contact force, such as the knee adduction moment. We developed a method to predict knee joint contact forces using motion analysis and a statistical regression model that can be implemented in near real-time. Gait waveform variables were deconstructed using principal component analysis and a linear regression was used to predict the principal component scores of the contact force waveforms. Knee joint contact force waveforms were reconstructed using the predicted scores. We tested our method using a heterogenous population of asymptomatic controls and subjects with knee osteoarthritis. The reconstructed contact force waveforms had mean (SD) RMS differences of 0.17 (0.05) bodyweight compared to the contact forces predicted by a musculoskeletal model. Our method successfully predicted subject-specific shape features of contact force waveforms and is a potentially powerful tool in biofeedback and clinical gait analysis.

  12. Normal anatomy and biomechanics of the knee.

    PubMed

    Flandry, Fred; Hommel, Gabriel

    2011-06-01

    Functionally, the knee comprises 2 articulations-the patellofemoral and tibiofemoral. Stability of the joint is governed by a combination of static ligaments, dynamic muscular forces, meniscocapsular aponeurosis, bony topography, and joint load. The surgeon is ill equipped to undertake surgical treatment of a dislocated knee without a sound footing in the anatomic complexities of this joint. We review the normal anatomy of the knee, emphasizing connective tissue structures and common injury patterns.

  13. The effects of neuromuscular exercise on medial knee joint load post-arthroscopic partial medial meniscectomy: 'SCOPEX', a randomised control trial protocol.

    PubMed

    Hall, Michelle; Hinman, Rana S; Wrigley, Tim V; Roos, Ewa M; Hodges, Paul W; Staples, Margaret; Bennell, Kim L

    2012-11-27

    Meniscectomy is a risk factor for knee osteoarthritis, with increased medial joint loading a likely contributor to the development and progression of knee osteoarthritis in this group. Therefore, post-surgical rehabilitation or interventions that reduce medial knee joint loading have the potential to reduce the risk of developing or progressing osteoarthritis. The primary purpose of this randomised, assessor-blind controlled trial is to determine the effects of a home-based, physiotherapist-supervised neuromuscular exercise program on medial knee joint load during functional tasks in people who have recently undergone a partial medial meniscectomy. 62 people aged 30-50 years who have undergone an arthroscopic partial medial meniscectomy within the previous 3 to 12 months will be recruited and randomly assigned to a neuromuscular exercise or control group using concealed allocation. The neuromuscular exercise group will attend 8 supervised exercise sessions with a physiotherapist and will perform 6 exercises at home, at least 3 times per week for 12 weeks. The control group will not receive the neuromuscular training program. Blinded assessment will be performed at baseline and immediately following the 12-week intervention. The primary outcomes are change in the peak external knee adduction moment measured by 3-dimensional analysis during normal paced walking and one-leg rise. Secondary outcomes include the change in peak external knee adduction moment during fast pace walking and one-leg hop and change in the knee adduction moment impulse during walking, one-leg rise and one-leg hop, knee and hip muscle strength, electromyographic muscle activation patterns, objective measures of physical function, as well as self-reported measures of physical function and symptoms and additional biomechanical parameters. The findings from this trial will provide evidence regarding the effect of a home-based, physiotherapist-supervised neuromuscular exercise program on medial knee joint load during various tasks in people with a partial medial meniscectomy. If shown to reduce the knee adduction moment, neuromuscular exercise has the potential to prevent the onset of osteoarthritis or slow its progression in those with early disease. Australian New Zealand Clinical Trials Registry reference: ACTRN12612000542897.

  14. Subject-Specific Modeling of Muscle Force and Knee Contact in Total Knee Arthroplasty

    PubMed Central

    Navacchia, Alessandro; Rullkoetter, Paul J.; Schütz, Pascal; List, Renate B.; Fitzpatrick, Clare K.; Shelburne, Kevin B.

    2017-01-01

    Understanding the mechanical loading environment and resulting joint mechanics for activities of daily living in total knee arthroplasty is essential to continuous improvement in implant design. Although survivorship of these devices is good, a substantial number of patients report dissatisfaction with the outcome of their procedure. Knowledge of in vivo kinematics and joint loading will enable improvement in preclinical assessment and refinement of implant geometry. The purpose of this investigation was to describe the mechanics of total knee arthroplasty during a variety of activities of daily living (gait, walking down stairs, and chair rise/sit). Estimates of muscle forces, tibial contact load, location, and pressure distribution was performed through a combination of mobile fluoroscopy data collection, musculoskeletal modeling, and finite element simulation. For the activities evaluated, joint compressive load was greatest during walking down stairs; however, the highest contact pressure occurred during chair rise/sit. The joint contact moment in the frontal plane was mainly varus for gait and walking down stairs, while it was valgus during chair rise/sit. Excursion of the center of pressure on the tibial component was similar during each activity and between the medial and lateral sides. The main determinants of center of pressure location were internal–external rotation, joint load, and tibial insert conformity. PMID:26792665

  15. Different knee joint loading patterns in ACL deficient copers and non-copers during walking.

    PubMed

    Alkjær, Tine; Henriksen, Marius; Simonsen, Erik B

    2011-04-01

    Rupture of the anterior cruciate ligament (ACL) causes changes in the walking pattern. ACL deficient subjects classified as copers and non-copers have been observed to adopt different post-injury walking patterns. How these different patterns affect the knee compression and shear forces is unresolved. Thus, the aim of the present study was to investigate how different walking patterns observed between copers, non-copers, and controls affect the knee compression and shear forces during walking. Three-dimensional gait analyses were performed in copers (n = 9), non-copers (n = 10), and control subjects (n =19). The net knee joint moment, knee joint reaction forces, and the sagittal knee joint angle were input parameters to a biomechanical model that assessed the knee compression and shear forces. The results showed that the non-copers walked with significantly reduced knee compression and shear forces than the controls. The overall knee compression force pattern was similar between the copers and controls, although this variable was significantly increased at heel strike in the copers compared to both non-copers and controls. The peak shear force was significantly dependent on the peak knee extensor moment. This covariance was significantly different between groups meaning that at a given knee extensor moment the shear force was significantly reduced in the copers compared to controls. The different knee joint loading patterns observed between non-copers and copers reflected the different walking strategies adopted by these groups, which may have implications for the knee joint stability. The strategy adopted by the copers may resemble an effective way to stabilize the knee joint during walking after an ACL rupture and that the knee kinematics may play a key role for this strategy. It is clinically relevant to investigate if gait retraining would enable non-copers to walk as copers and thereby improve their knee joint stability.

  16. Automatic locking orthotic knee device

    NASA Technical Reports Server (NTRS)

    Weddendorf, Bruce C. (Inventor)

    1993-01-01

    An articulated tang in clevis joint for incorporation in newly manufactured conventional strap-on orthotic knee devices or for replacing such joints in conventional strap-on orthotic knee devices is discussed. The instant tang in clevis joint allows the user the freedom to extend and bend the knee normally when no load (weight) is applied to the knee and to automatically lock the knee when the user transfers weight to the knee, thus preventing a damaged knee from bending uncontrollably when weight is applied to the knee. The tang in clevis joint of the present invention includes first and second clevis plates, a tang assembly and a spacer plate secured between the clevis plates. Each clevis plate includes a bevelled serrated upper section. A bevelled shoe is secured to the tank in close proximity to the bevelled serrated upper section of the clevis plates. A coiled spring mounted within an oblong bore of the tang normally urges the shoes secured to the tang out of engagement with the serrated upper section of each clevic plate to allow rotation of the tang relative to the clevis plate. When weight is applied to the joint, the load compresses the coiled spring, the serrations on each clevis plate dig into the bevelled shoes secured to the tang to prevent relative movement between the tang and clevis plates. A shoulder is provided on the tang and the spacer plate to prevent overextension of the joint.

  17. Predictive Simulations of Neuromuscular Coordination and Joint-Contact Loading in Human Gait.

    PubMed

    Lin, Yi-Chung; Walter, Jonathan P; Pandy, Marcus G

    2018-04-18

    We implemented direct collocation on a full-body neuromusculoskeletal model to calculate muscle forces, ground reaction forces and knee contact loading simultaneously for one cycle of human gait. A data-tracking collocation problem was solved for walking at the normal speed to establish the practicality of incorporating a 3D model of articular contact and a model of foot-ground interaction explicitly in a dynamic optimization simulation. The data-tracking solution then was used as an initial guess to solve predictive collocation problems, where novel patterns of movement were generated for walking at slow and fast speeds, independent of experimental data. The data-tracking solutions accurately reproduced joint motion, ground forces and knee contact loads measured for two total knee arthroplasty patients walking at their preferred speeds. RMS errors in joint kinematics were < 2.0° for rotations and < 0.3 cm for translations while errors in the model-computed ground-reaction and knee-contact forces were < 0.07 BW and < 0.4 BW, respectively. The predictive solutions were also consistent with joint kinematics, ground forces, knee contact loads and muscle activation patterns measured for slow and fast walking. The results demonstrate the feasibility of performing computationally-efficient, predictive, dynamic optimization simulations of movement using full-body, muscle-actuated models with realistic representations of joint function.

  18. The Effects of Common Footwear on Joint Loading in Osteoarthritis of the Knee

    PubMed Central

    Shakoor, Najia; Sengupta, Mondira; Foucher, Kharma C.; Wimmer, Markus A.; Fogg, Louis F.; Block, Joel A.

    2010-01-01

    Objective Elevated joint loads during walking have been associated with the severity and progression of osteoarthritis (OA) of the knee. Footwear may have the potential to alter these loads. This study compared the effects of several common shoe types on knee loading in subjects with OA of the knee. Methods 31 subjects (10 men, 21 women) with radiographic and symptomatic knee OA underwent gait analyses using an optoelectronic camera system and multi-component force plate. In each case, gait was evaluated barefoot and while wearing 4 different shoes: 1) clogs (Dansko®), 2) stability shoes (Brooks Addiction®), 3) flat walking shoes (Puma H Street®), and 4) flip-flops. Peak knee loads were compared between the different footwear conditions. Results Overall, the clogs and stability shoes, resulted in a significantly higher peak knee adduction moment (3.1±0.7 and 3.0±0.7 %BW*ht, respectively, ~15% higher, p<0.05)) compared with that of flat walking shoes (2.8±0.7%BW*ht), flip-flops (2.7±0.8%BW*ht) and barefoot walking (2.7±0.7%BW*ht). There were no statistically significant differences in knee loads with the flat walking shoes and flip-flops compared to barefoot walking. Conclusions These data confirm that footwear may have significant effects on knee loads during walking in subjects with OA of the knee. Flexibility and heel height may be important differentiating characteristics of shoes which affect knee loads. In light of the strong relationship between knee loading and OA, the design and biomechanical effects of modern footwear should be more closely evaluated in terms of their effects on the disease. PMID:20191571

  19. Effects of common footwear on joint loading in osteoarthritis of the knee.

    PubMed

    Shakoor, Najia; Sengupta, Mondira; Foucher, Kharma C; Wimmer, Markus A; Fogg, Louis F; Block, Joel A

    2010-07-01

    Elevated joint loads during walking have been associated with the severity and progression of osteoarthritis (OA) of the knee. Footwear may have the potential to alter these loads. This study compares the effects of several common shoe types on knee loading in subjects with OA of the knee. Thirty-one subjects (10 men, 21 women) with radiographic and symptomatic knee OA underwent gait analyses using an optoelectronic camera system and multicomponent force plate. In each case, gait was evaluated during barefoot walking and while wearing 4 different shoe types: 1) clogs, 2) stability shoes, 3) flat walking shoes, and 4) flip-flops. Peak knee loads were compared between the different footwear conditions. Overall, the clogs and stability shoes resulted in a significantly higher (approximately 15% higher) peak knee adduction moment (mean +/- SD 3.1 +/- 0.7 and 3.0 +/- 0.7 divided by body weight [BW] x height [H] multiplied by 100, respectively; P < 0.05) compared with that of flat walking shoes (mean +/- SD 2.8 +/- 0.7 %BW x H), flip-flops (mean +/- SD 2.7 +/- 0.8 %BW x H), and barefoot walking (mean +/- SD 2.7 +/- 0.7 %BW x H). There were no statistically significant differences in knee loads with the flat walking shoes and flip-flops compared with barefoot walking. These data confirm that footwear may have significant effects on knee loads during walking in subjects with OA of the knee. Flexibility and heel height may be important differentiating characteristics of shoes that affect knee loads. In light of the strong relationship between knee loading and OA, the design and biomechanical effects of modern footwear should be more closely evaluated in terms of their effects on the disease.

  20. Development and validation of a computational model of the knee joint for the evaluation of surgical treatments for osteoarthritis

    PubMed Central

    Mootanah, R.; Imhauser, C.W.; Reisse, F.; Carpanen, D.; Walker, R.W.; Koff, M.F.; Lenhoff, M.W.; Rozbruch, S.R.; Fragomen, A.T.; Dewan, Z.; Kirane, Y.M.; Cheah, Pamela A.; Dowell, J.K.; Hillstrom, H.J.

    2014-01-01

    A three-dimensional (3D) knee joint computational model was developed and validated to predict knee joint contact forces and pressures for different degrees of malalignment. A 3D computational knee model was created from high-resolution radiological images to emulate passive sagittal rotation (full-extension to 65°-flexion) and weight acceptance. A cadaveric knee mounted on a six-degree-of-freedom robot was subjected to matching boundary and loading conditions. A ligament-tuning process minimised kinematic differences between the robotically loaded cadaver specimen and the finite element (FE) model. The model was validated by measured intra-articular force and pressure measurements. Percent full scale error between EE-predicted and in vitro-measured values in the medial and lateral compartments were 6.67% and 5.94%, respectively, for normalised peak pressure values, and 7.56% and 4.48%, respectively, for normalised force values. The knee model can accurately predict normalised intra-articular pressure and forces for different loading conditions and could be further developed for subject-specific surgical planning. PMID:24786914

  1. Development and validation of a computational model of the knee joint for the evaluation of surgical treatments for osteoarthritis.

    PubMed

    Mootanah, R; Imhauser, C W; Reisse, F; Carpanen, D; Walker, R W; Koff, M F; Lenhoff, M W; Rozbruch, S R; Fragomen, A T; Dewan, Z; Kirane, Y M; Cheah, K; Dowell, J K; Hillstrom, H J

    2014-01-01

    A three-dimensional (3D) knee joint computational model was developed and validated to predict knee joint contact forces and pressures for different degrees of malalignment. A 3D computational knee model was created from high-resolution radiological images to emulate passive sagittal rotation (full-extension to 65°-flexion) and weight acceptance. A cadaveric knee mounted on a six-degree-of-freedom robot was subjected to matching boundary and loading conditions. A ligament-tuning process minimised kinematic differences between the robotically loaded cadaver specimen and the finite element (FE) model. The model was validated by measured intra-articular force and pressure measurements. Percent full scale error between FE-predicted and in vitro-measured values in the medial and lateral compartments were 6.67% and 5.94%, respectively, for normalised peak pressure values, and 7.56% and 4.48%, respectively, for normalised force values. The knee model can accurately predict normalised intra-articular pressure and forces for different loading conditions and could be further developed for subject-specific surgical planning.

  2. The effect of different decline angles on the biomechanics of double limb squats and the implications to clinical and training practice.

    PubMed

    Richards, Jim; Selfe, James; Sinclair, Jonathan; May, Karen; Thomas, Gavin

    2016-09-01

    Bilateral decline squatting has been well documented as a rehabilitation exercise, however, little information exists on the optimum angle of decline. The aim of this study was to determine the ankle and knee angle, moments, the patellofemoral joint load, patellar tendon load and associated muscle activity while performing a double limb squat at different decline angles and the implications to rehabilitation. Eighteen healthy subjects performed double limb squats at 6 angles of declination: 0, 5, 10, 15, 20 and 25 degrees. The range of motion of the knee and ankle joints, external moments, the patellofemoral/patellar tendon load and integrated EMG of gastrocnemius, tibialis anterior, rectus femoris and biceps femoris were evaluated. As the decline angle increased up to 20 degrees, the range of motion possible at the ankle and knee increased. The joint moments showed a decrease at the ankle up to 15 degrees and an increase at the knee up to 25 degrees, indicating a progressive reduction in loading around the ankle with a corresponding increase of the load in the patellar tendon and patellofemoral joint. These trends were supported by a decrease in tibialis anterior activity and an increase in the rectus femoris activity up to 15 degrees declination. However, gastrocnemius and biceps femoris activity increased as the decline angle increased above 15 degrees. The action of gastrocnemius and biceps femoris stabilises the knee against an anterior displacement of the femur on the tibia. These findings would suggest that there is little benefit in using a decline angle greater than 15-20 degrees unless the purpose is to offer an additional stability challenge to the knee joint.

  3. The effect of different decline angles on the biomechanics of double limb squats and the implications to clinical and training practice

    PubMed Central

    Richards, Jim; Selfe, James; Sinclair, Jonathan; May, Karen; Thomas, Gavin

    2016-01-01

    Abstract Bilateral decline squatting has been well documented as a rehabilitation exercise, however, little information exists on the optimum angle of decline. The aim of this study was to determine the ankle and knee angle, moments, the patellofemoral joint load, patellar tendon load and associated muscle activity while performing a double limb squat at different decline angles and the implications to rehabilitation. Eighteen healthy subjects performed double limb squats at 6 angles of declination: 0, 5, 10, 15, 20 and 25 degrees. The range of motion of the knee and ankle joints, external moments, the patellofemoral/patellar tendon load and integrated EMG of gastrocnemius, tibialis anterior, rectus femoris and biceps femoris were evaluated. As the decline angle increased up to 20 degrees, the range of motion possible at the ankle and knee increased. The joint moments showed a decrease at the ankle up to 15 degrees and an increase at the knee up to 25 degrees, indicating a progressive reduction in loading around the ankle with a corresponding increase of the load in the patellar tendon and patellofemoral joint. These trends were supported by a decrease in tibialis anterior activity and an increase in the rectus femoris activity up to 15 degrees declination. However, gastrocnemius and biceps femoris activity increased as the decline angle increased above 15 degrees. The action of gastrocnemius and biceps femoris stabilises the knee against an anterior displacement of the femur on the tibia. These findings would suggest that there is little benefit in using a decline angle greater than 15-20 degrees unless the purpose is to offer an additional stability challenge to the knee joint. PMID:28149400

  4. Effects of medial meniscus posterior horn avulsion and repair on tibiofemoral contact area and peak contact pressure with clinical implications.

    PubMed

    Marzo, John M; Gurske-DePerio, Jennifer

    2009-01-01

    Avulsion of the posterior horn attachment of the medial meniscus can compromise load-bearing ability, produce meniscus extrusion, and result in tibiofemoral joint-space narrowing, articular cartilage damage, and osteoarthritis. Avulsion of the posterior horn of the medial meniscus will increase peak contact pressure and decrease contact area in the medial compartment of the knee, and posterior horn repair will restore contact area and peak contact pressures to values of the control knee. Controlled laboratory study. Eight fresh-frozen human cadaveric knees had tibiofemoral peak contact pressures and contact area measured in the control state. The posterior horn of the medial meniscus was avulsed from its insertion and knees were retested. The meniscal avulsion was repaired by suture through a transosseous tunnel and the knees were tested a third time. Avulsion of the posterior horn attachment of the medial meniscus resulted in a significant increase in medial joint peak contact pressure (from 3841 kPa to 5084 kPa) and a significant decrease in contact area (from 594 mm(2) to 474 mm(2)). Repair of the avulsion resulted in restoration of the loading profiles to values equal to the control knee, with values of 3551 kPa for peak pressure and 592 mm(2) for contact area. Posterior horn medial meniscal root avulsion leads to deleterious alteration of the loading profiles of the medial joint compartment and results in loss of hoop stress resistance, meniscus extrusion, abnormal loading of the joint, and early knee medial-compartment degenerative changes. The repair technique described restores the ability of the medial meniscus to absorb hoop stress and eliminate joint-space narrowing, possibly decreasing the risk of degenerative disease.

  5. Effect of an ankle-foot orthosis on knee joint mechanics: a novel conservative treatment for knee osteoarthritis.

    PubMed

    Fantini Pagani, Cynthia H; Willwacher, Steffen; Benker, Rita; Brüggemann, Gert-Peter

    2014-12-01

    Several conservative treatments for medial knee osteoarthritis such as knee orthosis and laterally wedged insoles have been shown to reduce the load in the medial knee compartment. However, those treatments also present limitations such as patient compliance and inconsistent results regarding the treatment success. To analyze the effect of an ankle-foot orthosis on the knee adduction moment and knee joint alignment in the frontal plane in subjects with knee varus alignment. Controlled laboratory study, repeated measurements. In total, 14 healthy subjects with knee varus alignment were analyzed in five different conditions: without orthotic, with laterally wedged insoles, and with an ankle-foot orthosis in three different adjustments. Three-dimensional kinetic and kinematic data were collected during gait analysis. Significant decreases in knee adduction moment, knee lever arm, and joint alignment in the frontal plane were observed with the ankle-foot orthosis in all three different adjustments. No significant differences could be found in any parameter while using the laterally wedged insoles. The ankle-foot orthosis was effective in reducing the knee adduction moment. The decreases in this parameter seem to be achieved by changing the knee joint alignment and thereby reducing the knee lever arm in the frontal plane. This study presents a novel approach for reducing the load in the medial knee compartment, which could be developed as a new treatment option for patients with medial knee osteoarthritis. © The International Society for Prosthetics and Orthotics 2013.

  6. The effect of external ankle support on knee and ankle joint movement and loading in netball players.

    PubMed

    Vanwanseele, Benedicte; Stuelcken, Max; Greene, Andrew; Smith, Richard

    2014-09-01

    External ankle support has been successfully used to prevent ankle sprains. However, some recent studies have indicated that reducing ankle range of motion can place larger loads on the knee. The aim of this study was to investigate the effect of external ankle support (braces and high-top shoes) on the ankle and knee joint loading during a netball specific landing task. A repeated measure design. High performance netball players with no previously diagnosed severe ankle or knee injury (n=11) were recruited from NSW Institute of Sport netball programme. The kinematic and kinetic data were collected simultaneously using a 3-D Motion Analysis System and one Kistler force plate to measure ground reaction forces. Players performed a single leg landing whilst receiving a pass while wearing a standard netball shoe, the same shoe with a lace-up brace and a high-top shoe. Only the brace condition significantly reduced the ankle range of motion in the frontal plane (in/eversion) by 3.95 ± 3.74 degrees compared to the standard condition. No changes were found for the knee joint loading in the brace condition. The high-top shoes acted to increase the peak knee internal rotation moment by 15%. Both the brace and high-top conditions brought about increases in the peak ankle plantar flexion moment during the landing phase. Lace-up braces can be used by netball players to restrict ankle range of motion during a single leg landing while receiving a pass without increasing the load on the knee joint. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  7. Biofeedback for Gait Retraining Based on Real-Time Estimation of Tibiofemoral Joint Contact Forces.

    PubMed

    Pizzolato, Claudio; Reggiani, Monica; Saxby, David J; Ceseracciu, Elena; Modenese, Luca; Lloyd, David G

    2017-09-01

    Biofeedback assisted rehabilitation and intervention technologies have the potential to modify clinically relevant biomechanics. Gait retraining has been used to reduce the knee adduction moment, a surrogate of medial tibiofemoral joint loading often used in knee osteoarthritis research. In this paper, we present an electromyogram-driven neuromusculoskeletal model of the lower-limb to estimate, in real-time, the tibiofemoral joint loads. The model included 34 musculotendon units spanning the hip, knee, and ankle joints. Full-body inverse kinematics, inverse dynamics, and musculotendon kinematics were solved in real-time from motion capture and force plate data to estimate the knee medial tibiofemoral contact force (MTFF). We analyzed five healthy subjects while they were walking on an instrumented treadmill with visual biofeedback of their MTFF. Each subject was asked to modify their gait in order to vary the magnitude of their MTFF. All subjects were able to increase their MTFF, whereas only three subjects could decrease it, and only after receiving verbal suggestions about possible gait modification strategies. Results indicate the important role of knee muscle activation patterns in modulating the MTFF. While this paper focused on the knee, the technology can be extended to examine the musculoskeletal tissue loads at different sites of the human body.

  8. Focal cartilage defect compromises fluid-pressure dependent load support in the knee joint.

    PubMed

    Dabiri, Yaghoub; Li, LePing

    2015-06-01

    A focal cartilage defect involves tissue loss or rupture. Altered mechanics in the affected joint may play an essential role in the onset and progression of osteoarthritis. The objective of the present study was to determine the compromised load support in the human knee joint during defect progression from the cartilage surface to the cartilage-bone interface. Ten normal and defect cases were simulated with a previously tested 3D finite element model of the knee. The focal defects were considered in both condyles within high load-bearing regions. Fluid pressurization, anisotropic fibril-reinforcement, and depth-dependent mechanical properties were considered for the articular cartilages and menisci. The results showed that a small cartilage defect could cause 25% reduction in the load support of the knee joint due to a reduced capacity of fluid pressurization in the defect cartilage. A partial-thickness defect could cause a fluid pressure decrease or increase in the remaining underlying cartilage depending on the defect depth. A cartilage defect also increased the shear strain at the cartilage-bone interface, which was more significant with a full-thickness defect. The effect of cartilage defect on the fluid pressurization also depended on the defect sites and contact conditions. In conclusion, a focal cartilage defect causes a fluid-pressure dependent load reallocation and a compromised load support in the joint, which depend on the defect depth, site, and contact condition. Copyright © 2015 John Wiley & Sons, Ltd.

  9. Development of a Portable Knee Rehabilitation Device That Uses Mechanical Loading.

    PubMed

    Fitzwater, Daric; Dodge, Todd; Chien, Stanley; Yokota, Hiroki; Anwar, Sohel

    2013-12-01

    Joint loading is a recently developed mechanical modality, which potentially provides a therapeutic regimen to activate bone formation and prevent degradation of joint tissues. To our knowledge, however, few joint loading devices are available for clinical or point-of-care applications. Using a voice-coil actuator, we developed an electromechanical loading system appropriate for human studies and preclinical trials that should prove both safe and effective. Two specific tasks for this loading system were development of loading conditions (magnitude and frequency) suitable for humans, and provision of a convenient and portable joint loading apparatus. Desktop devices have been previously designed to evaluate the effects of various loading conditions using small and large animals. However, a portable knee loading device is more desirable from a usability point of view. In this paper, we present such a device that is designed to be portable, providing a compact, user-friendly loader. The portable device was employed to evaluate its capabilities using a human knee model. The portable device was characterized for force-pulse width modulation duty cycle and loading frequency properties. The results demonstrate that the device is capable of producing the necessary magnitude of forces at appropriate frequencies to promote the stimulation of bone growth and which can be used in clinical studies for further evaluations.

  10. Injury tolerance and moment response of the knee joint to combined valgus bending and shear loading.

    PubMed

    Bose, Dipan; Bhalla, Kavi S; Untaroiu, Costin D; Ivarsson, B Johan; Crandall, Jeff R; Hurwitz, Shepard

    2008-06-01

    Valgus bending and shearing of the knee have been identified as primary mechanisms of injuries in a lateral loading environment applicable to pedestrian-car collisions. Previous studies have reported on the structural response of the knee joint to pure valgus bending and lateral shearing, as well as the estimated injury thresholds for the knee bending angle and shear displacement based on experimental tests. However, epidemiological studies indicate that most knee injuries are due to the combined effects of bending and shear loading. Therefore, characterization of knee stiffness for combined loading and the associated injury tolerances is necessary for developing vehicle countermeasures to mitigate pedestrian injuries. Isolated knee joint specimens (n=40) from postmortem human subjects were tested in valgus bending at a loading rate representative of a pedestrian-car impact. The effect of lateral shear force combined with the bending moment on the stiffness response and the injury tolerances of the knee was concurrently evaluated. In addition to the knee moment-angle response, the bending angle and shear displacement corresponding to the first instance of primary ligament failure were determined in each test. The failure displacements were subsequently used to estimate an injury threshold function based on a simplified analytical model of the knee. The validity of the determined injury threshold function was subsequently verified using a finite element model. Post-test necropsy of the knees indicated medial collateral ligament injury consistent with the clinical injuries observed in pedestrian victims. The moment-angle response in valgus bending was determined at quasistatic and dynamic loading rates and compared to previously published test data. The peak bending moment values scaled to an average adult male showed no significant change with variation in the superimposed shear load. An injury threshold function for the knee in terms of bending angle and shear displacement was determined by performing regression analysis on the experimental data. The threshold values of the bending angle (16.2 deg) and shear displacement (25.2 mm) estimated from the injury threshold function were in agreement with previously published knee injury threshold data. The continuous knee injury function expressed in terms of bending angle and shear displacement enabled injury prediction for combined loading conditions such as those observed in pedestrian-car collisions.

  11. The effects of neuromuscular exercise on medial knee joint load post-arthroscopic partial medial meniscectomy: ‘SCOPEX’ a randomised control trial protocol

    PubMed Central

    2012-01-01

    Background Meniscectomy is a risk factor for knee osteoarthritis, with increased medial joint loading a likely contributor to the development and progression of knee osteoarthritis in this group. Therefore, post-surgical rehabilitation or interventions that reduce medial knee joint loading have the potential to reduce the risk of developing or progressing osteoarthritis. The primary purpose of this randomised, assessor-blind controlled trial is to determine the effects of a home-based, physiotherapist-supervised neuromuscular exercise program on medial knee joint load during functional tasks in people who have recently undergone a partial medial meniscectomy. Methods/design 62 people aged 30–50 years who have undergone an arthroscopic partial medial meniscectomy within the previous 3 to 12 months will be recruited and randomly assigned to a neuromuscular exercise or control group using concealed allocation. The neuromuscular exercise group will attend 8 supervised exercise sessions with a physiotherapist and will perform 6 exercises at home, at least 3 times per week for 12 weeks. The control group will not receive the neuromuscular training program. Blinded assessment will be performed at baseline and immediately following the 12-week intervention. The primary outcomes are change in the peak external knee adduction moment measured by 3-dimensional analysis during normal paced walking and one-leg rise. Secondary outcomes include the change in peak external knee adduction moment during fast pace walking and one-leg hop and change in the knee adduction moment impulse during walking, one-leg rise and one-leg hop, knee and hip muscle strength, electromyographic muscle activation patterns, objective measures of physical function, as well as self-reported measures of physical function and symptoms and additional biomechanical parameters. Discussion The findings from this trial will provide evidence regarding the effect of a home-based, physiotherapist-supervised neuromuscular exercise program on medial knee joint load during various tasks in people with a partial medial meniscectomy. If shown to reduce the knee adduction moment, neuromuscular exercise has the potential to prevent the onset of osteoarthritis or slow its progression in those with early disease. Trial Registration Australian New Zealand Clinical Trials Registry reference: ACTRN12612000542897 PMID:23181415

  12. Predicting dynamic knee joint load with clinical measures in people with medial knee osteoarthritis.

    PubMed

    Hunt, Michael A; Bennell, Kim L

    2011-08-01

    Knee joint loading, as measured by the knee adduction moment (KAM), has been implicated in the pathogenesis of knee osteoarthritis (OA). Given that the KAM can only currently be accurately measured in the laboratory setting with sophisticated and expensive equipment, its utility in the clinical setting is limited. This study aimed to determine the ability of a combination of four clinical measures to predict KAM values. Three-dimensional motion analysis was used to calculate the peak KAM at a self-selected walking speed in 47 consecutive individuals with medial compartment knee OA and varus malalignment. Clinical predictors included: body mass; tibial angle measured using an inclinometer; walking speed; and visually observed trunk lean toward the affected limb during the stance phase of walking. Multiple linear regression was performed to predict KAM magnitudes using the four clinical measures. A regression model including body mass (41% explained variance), tibial angle (17% explained variance), and walking speed (9% explained variance) explained a total of 67% of variance in the peak KAM. Our study demonstrates that a set of measures easily obtained in the clinical setting (body mass, tibial alignment, and walking speed) can help predict the KAM in people with medial knee OA. Identifying those patients who are more likely to experience high medial knee loads could assist clinicians in deciding whether load-modifying interventions may be appropriate for patients, whilst repeated assessment of joint load could provide a mechanism to monitor disease progression or success of treatment. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. Altered Tibiofemoral Joint Contact Mechanics and Kinematics in Patients with Knee Osteoarthritis and Episodic Complaints of Joint Instability

    PubMed Central

    Farrokhi, Shawn; Voycheck, Carrie A.; Klatt, Brian A.; Gustafson, Jonathan A.; Tashman, Scott; Fitzgerald, G. Kelley

    2014-01-01

    Background To evaluate knee joint contact mechanics and kinematics during the loading response phase of downhill gait in knee osteoarthritis patients with self-reported instability. Methods Forty-three subjects, 11 with medial compartment knee osteoarthritis and self-reported instability (unstable), 7 with medial compartment knee osteoarthritis but no reports of instability (stable), and 25 without knee osteoarthritis or instability (control) underwent Dynamic Stereo X-ray analysis during a downhill gait task on a treadmill. Findings The medial compartment contact point excursions were longer in the unstable group compared to the stable (p=0.046) and the control groups (p=0.016). The peak medial compartment contact point velocity was also greater for the unstable group compared to the stable (p=0.047) and control groups (p=0.022). Additionally, the unstable group demonstrated a coupled movement pattern of knee extension and external rotation after heel contact which was different than the coupled motion of knee flexion and internal rotation demonstrated by stable and control groups. Interpretation Our findings suggest that knee joint contact mechanics and kinematics are altered during the loading response phase of downhill gait in knee osteoarthritis patients with self-reported instability. The observed longer medial compartment contact point excursions and higher velocities represent objective signs of mechanical instability that may place the arthritic knee joint at increased risk for disease progression. Further research is indicated to explore the clinical relevance of altered contact mechanics and kinematics during other common daily activities and to assess the efficacy of rehabilitation programs to improve altered joint biomechanics in knee osteoarthritis patients with self-reported instability. PMID:24856791

  14. Muscle Activation Profiles and Co-Activation of Quadriceps and Hamstring Muscles around Knee Joint in Indian Primary Osteoarthritis Knee Patients.

    PubMed

    Sharma, Sanjeev Kumar; Yadav, Shiv Lal; Singh, U; Wadhwa, Sanjay

    2017-05-01

    Osteoarthritis (OA) of knee is a common joint disease. It is associated with reduced knee joint stability due to impaired quadriceps strength, pain, and an altered joint structure. There is altered muscle activation in knee OA patients, which interferes with normal load distribution around the knee and facilitates disease progression. Our primary aim was to determine activation patterns of the muscles i.e., quadriceps and hamstrings in knee OA patients during walking. We also studied co-activation of muscles around knee joint in primary OA knee patients including directed medial and lateral co-contractions. This observational study was done at Department of Physical Medicine and Rehabilitation, All India Institute of Medical Sciences, New Delhi, India. Fourty-four patients with medial compartment primary knee OA were included in study after satisfying inclusion and exclusion criteria. All the patients were assessed for mean, peak and integrated Root Mean Square (RMS), EMG values, muscle activation patterns and co-activation of muscles around knee joint by surface Electromyography (EMG) analysis of Vastus Medialis Obliques (VMO), Vastus Lateralis (VL), Semitendinosus (SMT) and Biceps Femoris (BF) muscles during gait cycle. The EMG waveform for each muscle was amplitude normalized and time normalized to 100% of gait cycle and plotted on graph. Quantitative variables were assessed for normal distribution and accordingly mean±SD or median (range), as appropriate, was computed. For primary OA knee, mean age 61±5 years, mean weight 63.7±10.1 kg, mean height 153.9±7.2 cm, and mean Body Mass Index (BMI) 26.8±3.0 kg/m 2 was found. The muscle activity of hamstrings (SMT muscle and BF) was increased during midstance, late stance and early swing phase of gait cycle as compared to quadriceps (VMO and VL) muscle activity respectively, suggesting co-contraction of opposing muscles around knee joint. Patients with knee OA walk with increased hamstring muscle activity (during late stance and early swing phase) and reduced quadriceps recruitment. Altered neuro-muscular control around knee interferes with normal load distribution and facilitates disease progression in knee joint.

  15. Muscle Activation Profiles and Co-Activation of Quadriceps and Hamstring Muscles around Knee Joint in Indian Primary Osteoarthritis Knee Patients

    PubMed Central

    Yadav, Shiv Lal; Singh, U; Wadhwa, Sanjay

    2017-01-01

    Introduction Osteoarthritis (OA) of knee is a common joint disease. It is associated with reduced knee joint stability due to impaired quadriceps strength, pain, and an altered joint structure. There is altered muscle activation in knee OA patients, which interferes with normal load distribution around the knee and facilitates disease progression. Aim Our primary aim was to determine activation patterns of the muscles i.e., quadriceps and hamstrings in knee OA patients during walking. We also studied co-activation of muscles around knee joint in primary OA knee patients including directed medial and lateral co-contractions. Materials and Methods This observational study was done at Department of Physical Medicine and Rehabilitation, All India Institute of Medical Sciences, New Delhi, India. Fourty-four patients with medial compartment primary knee OA were included in study after satisfying inclusion and exclusion criteria. All the patients were assessed for mean, peak and integrated Root Mean Square (RMS), EMG values, muscle activation patterns and co-activation of muscles around knee joint by surface Electromyography (EMG) analysis of Vastus Medialis Obliques (VMO), Vastus Lateralis (VL), Semitendinosus (SMT) and Biceps Femoris (BF) muscles during gait cycle. The EMG waveform for each muscle was amplitude normalized and time normalized to 100% of gait cycle and plotted on graph. Quantitative variables were assessed for normal distribution and accordingly mean±SD or median (range), as appropriate, was computed. Results For primary OA knee, mean age 61±5 years, mean weight 63.7±10.1 kg, mean height 153.9±7.2 cm, and mean Body Mass Index (BMI) 26.8±3.0 kg/m2 was found. The muscle activity of hamstrings (SMT muscle and BF) was increased during midstance, late stance and early swing phase of gait cycle as compared to quadriceps (VMO and VL) muscle activity respectively, suggesting co-contraction of opposing muscles around knee joint. Conclusion Patients with knee OA walk with increased hamstring muscle activity (during late stance and early swing phase) and reduced quadriceps recruitment. Altered neuro-muscular control around knee interferes with normal load distribution and facilitates disease progression in knee joint. PMID:28658860

  16. The KineSpring® Knee Implant System: an implantable joint-unloading prosthesis for treatment of medial knee osteoarthritis

    PubMed Central

    Clifford, Anton G; Gabriel, Stefan M; O’Connell, Mary; Lowe, David; Miller, Larry E; Block, Jon E

    2013-01-01

    Symptomatic medial compartment knee osteoarthritis (OA) is the leading cause of musculoskeletal pain and disability in adults. Therapies intended to unload the medial knee compartment have yielded unsatisfactory results due to low patient compliance with conservative treatments and high complication rates with surgical options. There is no widely available joint-unloading treatment for medial knee OA that offers clinically important symptom alleviation, low complication risk, and high patient acceptance. The KineSpring® Knee Implant System (Moximed, Inc, Hayward, CA, USA) is a first-of-its-kind, implantable, extra-articular, extra-capsular prosthesis intended to alleviate knee OA-related symptoms by reducing medial knee compartment loading while overcoming the limitations of traditional joint-unloading therapies. Preclinical and clinical studies have demonstrated excellent prosthesis durability, substantial reductions in medial compartment and total joint loads, and clinically important improvements in OA-related pain and function. The purpose of this report is to describe the KineSpring System, including implant characteristics, principles of operation, indications for use, patient selection criteria, surgical technique, postoperative care, preclinical testing, and clinical experience. The KineSpring System has potential to bridge the gap between ineffective conservative treatments and irreversible surgical interventions for medial compartment knee OA. PMID:23717052

  17. Parameters Estimation For A Patellofemoral Joint Of A Human Knee Using A Vector Method

    NASA Astrophysics Data System (ADS)

    Ciszkiewicz, A.; Knapczyk, J.

    2015-08-01

    Position and displacement analysis of a spherical model of a human knee joint using the vector method was presented. Sensitivity analysis and parameter estimation were performed using the evolutionary algorithm method. Computer simulations for the mechanism with estimated parameters proved the effectiveness of the prepared software. The method itself can be useful when solving problems concerning the displacement and loads analysis in the knee joint.

  18. Comparison of Joint Loading in Badminton Lunging between Professional and Amateur Badminton Players

    PubMed Central

    Fu, Lin

    2017-01-01

    The knee and ankle are the two most injured joints associated with the sport of badminton. This study evaluates biomechanical factors between professional and amateur badminton players using an injury mechanism model. The aim of this study was to investigate the kinematic motion and kinetic loading differences of the right knee and ankle while performing a maximal right lunge. Amateur players exhibited greater ankle range of motion (p < 0.05, r = 0.89) and inversion joint moment (p < 0.05, r = 0.54) in the frontal plane as well as greater internal joint rotation moment (p < 0.05, r = 0.28) in the horizontal plane. In contrast, professional badminton players presented a greater knee joint moment in the sagittal (p < 0.05, r = 0.59) and frontal (p < 0.05, r = 0.37) planes, which may be associated with increased knee ligamentous injury risk. To avoid injury, the players need to forcefully extend the knee with internal rotation, strengthen the muscles around the ankle ligament, and maximise joint coordination during training. The injuries recorded and the forces responsible for the injuries seem to have developed during training activity. Training programmes and injury prevention strategies for badminton players should account for these findings to reduce potential injury to the ankle and knee. PMID:28694684

  19. Patellofemoral joint contact forces during activities with high knee flexion.

    PubMed

    Trepczynski, Adam; Kutzner, Ines; Kornaropoulos, Evgenios; Taylor, William R; Duda, Georg N; Bergmann, Georg; Heller, Markus O

    2012-03-01

    The patellofemoral (PF) joint plays an essential role in knee function, but little is known about the in vivo loading conditions at the joint. We hypothesized that the forces at the PF joint exceed the tibiofemoral (TF) forces during activities with high knee flexion. Motion analysis was performed in two patients with telemetric knee implants during walking, stair climbing, sit-to-stand, and squat. TF and PF forces were calculated using a musculoskeletal model, which was validated against the simultaneously measured in vivo TF forces, with mean errors of 10% and 21% for the two subjects. The in vivo peak TF forces of 2.9-3.4 bodyweight (BW) varied little across activities, while the peak PF forces showed significant variability, ranging from less than 1 BW during walking to more than 3 BW during high flexion activities, exceeding the TF forces. Together with previous in vivo measurements at the hip and knee, the PF forces determined here provide evidence that peak forces across these joints reach values of around 3 BW during high flexion activities, also suggesting that the in vivo loading conditions at the knee can only be fully understood if the forces at the TF and the PF joints are considered together. Copyright © 2011 Orthopaedic Research Society.

  20. Biomechanical Evaluation of Knee Joint Laxities and Graft Forces After Anterior Cruciate Ligament Reconstruction by Anteromedial Portal, Outside-In, and Transtibial Techniques

    PubMed Central

    Sim, Jae Ang; Gadikota, Hemanth R.; Li, Jing-Sheng; Li, Guoan; Gill, Thomas J.

    2013-01-01

    Background Recently, anatomic anterior cruciate ligament (ACL) reconstruction is emphasized to improve joint laxity and to potentially avert initiation of cartilage degeneration. There is a paucity of information on the efficacy of ACL reconstructions by currently practiced tunnel creation techniques in restoring normal joint laxity. Study Design Controlled laboratory study. Hypothesis Anterior cruciate ligament reconstruction by the anteromedial (AM) portal technique, outside-in (OI) technique, and modified transtibial (TT) technique can equally restore the normal knee joint laxity and ACL forces. Methods Eight fresh-frozen human cadaveric knee specimens were tested using a robotic testing system under an anterior tibial load (134 N) at 0°, 30°, 60°, and 90° of flexion and combined torques (10-N·m valgus and 5-N·m internal tibial torques) at 0° and 30° of flexion. Knee joint kinematics, ACL, and ACL graft forces were measured in each knee specimen under 5 different conditions (ACL-intact knee, ACL-deficient knee, ACL-reconstructed knee by AM portal technique, ACL-reconstructed knee by OI technique, and ACL-reconstructed knee by TT technique). Results Under anterior tibial load, no significant difference was observed between the 3 reconstructions in terms of restoring anterior tibial translation (P > .05). However, none of the 3 ACL reconstruction techniques could completely restore the normal anterior tibial translations (P <.05). Under combined tibial torques, both AM portal and OI techniques closely restored the normal knee anterior tibial translation (P > .05) at 0° of flexion but could not do so at 30° of flexion (P <.05). The ACL reconstruction by the TT technique was unable to restore normal anterior tibial translations at both 0° and 30° of flexion under combined tibial torques (P <.05). Forces experienced by the ACL grafts in the 3 reconstruction techniques were lower than those experienced by normal ACL under both the loading conditions. Conclusion Anterior cruciate ligament reconstructions by AM portal, OI, and modified TT techniques are biomechanically comparable with each other in restoring normal knee joint laxity and in situ ACL forces. Clinical Relevance Anterior cruciate ligament reconstructions by AM portal, OI, and modified TT techniques result in similar knee joint laxities. Technical perils and pearls should be carefully considered before choosing a tunnel creating technique. PMID:21908717

  1. Neuromuscular fatigue and tibiofemoral joint biomechanics when transitioning from non-weight bearing to weight bearing.

    PubMed

    Schmitz, Randy J; Kim, Hyunsoo; Shultz, Sandra J

    2015-01-01

    Fatigue is suggested to be a risk factor for anterior cruciate ligament injury. Fatiguing exercise can affect neuromuscular control and laxity of the knee joint, which may render the knee less able to resist externally applied loads. Few authors have examined the effects of fatiguing exercise on knee biomechanics during the in vivo transition of the knee from non-weight bearing to weight bearing, the time when anterior cruciate ligament injury likely occurs. To investigate the effect of fatiguing exercise on tibiofemoral joint biomechanics during the transition from non-weight bearing to early weight bearing. Cross-sectional study. Research laboratory. Ten participants (5 men and 5 women; age = 25.3 ± 4.0 years) with no previous history of knee-ligament injury to the dominant leg. Participants were tested before (preexercise) and after (postexercise) a protocol consisting of repeated leg presses (15 repetitions from 10°-40° of knee flexion, 10 seconds' rest) against a 60% body-weight load until they were unable to complete a full bout of repetitions. Electromagnetic sensors measured anterior tibial translation and knee-flexion excursion during the application of a 40% body-weight axial compressive load to the bottom of the foot, simulating weight acceptance. A force transducer recorded axial compressive force. The axial compressive force (351.8 ± 44.3 N versus 374.0 ± 47.9 N; P = .018), knee-flexion excursion (8.0° ± 4.0° versus 10.2° ± 3.7°; P = .046), and anterior tibial translation (6.7 ± 1.7 mm versus 8.2 ± 1.9 mm; P < .001) increased from preexercise to postexercise. No significant correlations were noted. Neuromuscular fatigue may impair initial knee-joint stabilization during weight acceptance, leading to greater accessory motion at the knee and the potential for greater anterior cruciate ligament loading.

  2. How joint torques affect hamstring injury risk in sprinting swing-stance transition.

    PubMed

    Sun, Yuliang; Wei, Shutao; Zhong, Yunjian; Fu, Weijie; Li, Li; Liu, Yu

    2015-02-01

    The potential mechanisms of hamstring strain injuries in athletes are not well understood. The study, therefore, was aimed at understanding hamstring mechanics by studying loading conditions during maximum-effort overground sprinting. Three-dimensional kinematics and ground reaction force data were collected from eight elite male sprinters sprinting at their maximum effort. Maximal isometric torques of the hip and knee were also collected. Data from the sprinting gait cycle were analyzed via an intersegmental dynamics approach, and the different joint torque components were calculated. During the initial stance phase, the ground reaction force passed anteriorly to the knee and hip, producing an extension torque at the knee and a flexion torque at the hip joint. Thus, the active muscle torque functioned to produce flexion torque at the knee and extension torque at the hip. The maximal muscle torque at the knee joint was 1.4 times the maximal isometric knee flexion torque. During the late swing phase, the muscle torque counterbalanced the motion-dependent torque and acted to flex the knee joint and extend the hip joint. The loading conditions on the hamstring muscles were similar to those of the initial stance phase. During both the initial stance and late swing phases, the large passive torques at both the knee and hip joints acted to lengthen the hamstring muscles. The active muscle torques generated mainly by the hamstrings functioned to counteract those passive effects. As a result, during sprinting or high-speed locomotion, the hamstring muscles may be more susceptible to high risk of strain injury during these two phases.

  3. How Joint Torques Affect Hamstring Injury Risk in Sprinting Swing–Stance Transition

    PubMed Central

    SUN, YULIANG; WEI, SHUTAO; ZHONG, YUNJIAN; FU, WEIJIE; LI, LI; LIU, YU

    2015-01-01

    ABSTRACT Purpose The potential mechanisms of hamstring strain injuries in athletes are not well understood. The study, therefore, was aimed at understanding hamstring mechanics by studying loading conditions during maximum-effort overground sprinting. Methods Three-dimensional kinematics and ground reaction force data were collected from eight elite male sprinters sprinting at their maximum effort. Maximal isometric torques of the hip and knee were also collected. Data from the sprinting gait cycle were analyzed via an intersegmental dynamics approach, and the different joint torque components were calculated. Results During the initial stance phase, the ground reaction force passed anteriorly to the knee and hip, producing an extension torque at the knee and a flexion torque at the hip joint. Thus, the active muscle torque functioned to produce flexion torque at the knee and extension torque at the hip. The maximal muscle torque at the knee joint was 1.4 times the maximal isometric knee flexion torque. During the late swing phase, the muscle torque counterbalanced the motion-dependent torque and acted to flex the knee joint and extend the hip joint. The loading conditions on the hamstring muscles were similar to those of the initial stance phase. Conclusions During both the initial stance and late swing phases, the large passive torques at both the knee and hip joints acted to lengthen the hamstring muscles. The active muscle torques generated mainly by the hamstrings functioned to counteract those passive effects. As a result, during sprinting or high-speed locomotion, the hamstring muscles may be more susceptible to high risk of strain injury during these two phases. PMID:24911288

  4. Recent advances in computational mechanics of the human knee joint.

    PubMed

    Kazemi, M; Dabiri, Y; Li, L P

    2013-01-01

    Computational mechanics has been advanced in every area of orthopedic biomechanics. The objective of this paper is to provide a general review of the computational models used in the analysis of the mechanical function of the knee joint in different loading and pathological conditions. Major review articles published in related areas are summarized first. The constitutive models for soft tissues of the knee are briefly discussed to facilitate understanding the joint modeling. A detailed review of the tibiofemoral joint models is presented thereafter. The geometry reconstruction procedures as well as some critical issues in finite element modeling are also discussed. Computational modeling can be a reliable and effective method for the study of mechanical behavior of the knee joint, if the model is constructed correctly. Single-phase material models have been used to predict the instantaneous load response for the healthy knees and repaired joints, such as total and partial meniscectomies, ACL and PCL reconstructions, and joint replacements. Recently, poromechanical models accounting for fluid pressurization in soft tissues have been proposed to study the viscoelastic response of the healthy and impaired knee joints. While the constitutive modeling has been considerably advanced at the tissue level, many challenges still exist in applying a good material model to three-dimensional joint simulations. A complete model validation at the joint level seems impossible presently, because only simple data can be obtained experimentally. Therefore, model validation may be concentrated on the constitutive laws using multiple mechanical tests of the tissues. Extensive model verifications at the joint level are still crucial for the accuracy of the modeling.

  5. Recent Advances in Computational Mechanics of the Human Knee Joint

    PubMed Central

    Kazemi, M.; Dabiri, Y.; Li, L. P.

    2013-01-01

    Computational mechanics has been advanced in every area of orthopedic biomechanics. The objective of this paper is to provide a general review of the computational models used in the analysis of the mechanical function of the knee joint in different loading and pathological conditions. Major review articles published in related areas are summarized first. The constitutive models for soft tissues of the knee are briefly discussed to facilitate understanding the joint modeling. A detailed review of the tibiofemoral joint models is presented thereafter. The geometry reconstruction procedures as well as some critical issues in finite element modeling are also discussed. Computational modeling can be a reliable and effective method for the study of mechanical behavior of the knee joint, if the model is constructed correctly. Single-phase material models have been used to predict the instantaneous load response for the healthy knees and repaired joints, such as total and partial meniscectomies, ACL and PCL reconstructions, and joint replacements. Recently, poromechanical models accounting for fluid pressurization in soft tissues have been proposed to study the viscoelastic response of the healthy and impaired knee joints. While the constitutive modeling has been considerably advanced at the tissue level, many challenges still exist in applying a good material model to three-dimensional joint simulations. A complete model validation at the joint level seems impossible presently, because only simple data can be obtained experimentally. Therefore, model validation may be concentrated on the constitutive laws using multiple mechanical tests of the tissues. Extensive model verifications at the joint level are still crucial for the accuracy of the modeling. PMID:23509602

  6. Wide step width reduces knee abduction moment of obese adults during stair negotiation.

    PubMed

    Yocum, Derek; Weinhandl, Joshua T; Fairbrother, Jeffrey T; Zhang, Songning

    2018-05-15

    An increased likelihood of developing obesity-related knee osteoarthritis may be associated with increased peak internal knee abduction moments (KAbM). Increases in step width (SW) may act to reduce this moment. The purpose of this study was to determine the effects of increased SW on knee biomechanics during stair negotiation of healthy-weight and obese participants. Participants (24: 10 obese and 14 healthy-weight) used stairs and walked over level ground while walking at their preferred speed in two different SW conditions - preferred and wide (200% preferred). A 2 × 2 (group × condition) mixed model analysis of variance was performed to analyze differences between groups and conditions (p < 0.05). Increased SW increased the loading-response peak knee extension moment during descent and level gait, decreased loading-response KAbMs, knee extension and abduction range of motion (ROM) during ascent, and knee adduction ROM during descent. Increased SW increased loading-response peak mediolateral ground reaction force (GRF), increased peak knee abduction angle during ascent, and decreased peak knee adduction angle during descent and level gait. Obese participants experienced disproportionate changes in loading-response mediolateral GRF, KAbM and peak adduction angle during level walking, and peak knee abduction angle and ROM during ascent. Increased SW successfully decreased loading-response peak KAbM. Implications of this finding are that increased SW may decrease medial compartment knee joint loading, decreasing pain and reducing joint deterioration. Increased SW influenced obese and healthy-weight participants differently and should be investigated further. Copyright © 2018. Published by Elsevier Ltd.

  7. Spatial variation of fixed charge density in knee joint cartilage from sodium MRI - Implication on knee joint mechanics under static loading.

    PubMed

    Räsänen, Lasse P; Tanska, Petri; Mononen, Mika E; Lammentausta, Eveliina; Zbýň, Štefan; Venäläinen, Mikko S; Szomolanyi, Pavol; van Donkelaar, Corrinus C; Jurvelin, Jukka S; Trattnig, Siegfried; Nieminen, Miika T; Korhonen, Rami K

    2016-10-03

    The effects of fixed charge density (FCD) and cartilage swelling have not been demonstrated on cartilage mechanics on knee joint level before. In this study, we present how the spatial and local variations of FCD affects the mechanical response of the knee joint cartilage during standing (half of the body weight, 13 minutes) using finite element (FE) modeling. The FCD distribution of tibial cartilage of an asymptomatic subject was determined using sodium ( 23 Na) MRI at 7T and implemented into a 3-D FE-model of the knee joint (Subject-specific model, FCD: 0.18±0.08 mEq/ml). Tissue deformation in the Subject-specific model was validated against experimental, in vivo loading of the joint conducted with a MR-compatible compression device. For comparison, models with homogeneous FCD distribution (homogeneous model) and FCD distribution obtained from literature (literature model) were created. Immediately after application of the load (dynamic response), the variations in FCD had minor effects on cartilage stresses and strains. After 13 minutes of standing, the spatial and local variations in FCD had most influence on axial strains. In the superficial tibial cartilage in the Subject-specific model, axial strains were increased up to +13% due to smaller FCD (mean -11%), as compared to the homogeneous model. Compared to the literature model, those were decreased up to -18% due to greater FCD (mean +7%). The findings demonstrate that the spatial and local FCD variations in cartilage modulates strains in knee joint cartilage. Thereby, the results highlight the mechanical importance of site-specific content of proteoglycans in cartilage. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Reduced knee flexion is a possible cause of increased loading rates in individuals with patellofemoral pain.

    PubMed

    Silva, Danilo de Oliveira; Briani, Ronaldo Valdir; Pazzinatto, Marcella Ferraz; Ferrari, Deisi; Aragão, Fernando Amâncio; Azevedo, Fábio Mícolis de

    2015-11-01

    Stair ascent is an activity that exacerbates symptoms of individuals with patellofemoral pain. The discomfort associated with this activity usually results in gait modification such as reduced knee flexion in an attempt to reduce pain. Although such compensatory strategy is a logical approach to decrease pain, it also reduces the normal active shock absorption increasing loading rates and may lead to deleterious and degenerative changes of the knee joint. Thus, the aims of this study were (i) to investigate whether there is reduced knee flexion in adults with PFP compared to healthy controls; and (ii) to analyze loading rates in these subjects, during stair climbing. Twenty-nine individuals with patellofemoral pain and twenty-five control individuals (18-30 years) participated in this study. Each subject underwent three-dimensional kinematic and kinetic analyses during stair climbing on two separate days. Between-groups analyses of variance were performed to identify differences in peak knee flexion and loading rates. Intraclass correlation coefficient was performed to verify the reliability of the variables. On both days, the patellofemoral pain group demonstrated significantly reduced peak knee flexion and increased loading rates. In addition, the two variables obtained high to very high reliability. Reduced knee flexion during stair climbing as a strategy to avoid anterior knee pain does not seem to be healthy for lower limb mechanical distributions. Repeated loading at higher loading rates may be damaging to lower limb joints. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Sensate Scaffolds Can Reliably Detect Joint Loading

    PubMed Central

    Bliss, C. L.; Szivek, J. A.; Tellis, B. C.; Margolis, D. S.; Schnepp, A. B.; Ruth, J. T.

    2008-01-01

    Treatment of cartilage defects is essential to the prevention of osteoarthritis. Scaffold-based cartilage tissue engineering shows promise as a viable technique to treat focal defects. Added functionality can be achieved by incorporating strain gauges into scaffolds, thereby providing a real-time diagnostic measurement of joint loading. Strain-gauged scaffolds were placed into the medial femoral condyles of 14 adult canine knees and benchtop tested. Loads between 75 and 130 N were applied to the stifle joints at 30°, 50°, and 70° of flexion. Strain-gauged scaffolds were able to reliably assess joint loading at all applied flexion angles and loads. Pressure sensitive films were used to determine joint surface pressures during loading and to assess the effect of scaffold placement on joint pressures. A comparison of peak pressures in control knees and joints with implanted scaffolds, as well as a comparison of pressures before and after scaffold placement, showed that strain-gauged scaffold implantation did not significantly alter joint pressures. Future studies could possibly use strain-gauged scaffolds to clinically establish normal joint loads and to determine loads that are damaging to both healthy and tissue-engineered cartilage. Strain-gauged scaffolds may significantly aid the development of a functional engineered cartilage tissue substitute as well as provide insight into the native environment of cartilage. PMID:16941586

  10. Subject-specific modeling of muscle force and knee contact in total knee arthroplasty.

    PubMed

    Navacchia, Alessandro; Rullkoetter, Paul J; Schütz, Pascal; List, Renate B; Fitzpatrick, Clare K; Shelburne, Kevin B

    2016-09-01

    Understanding the mechanical loading environment and resulting joint mechanics for activities of daily living in total knee arthroplasty is essential to continuous improvement in implant design. Although survivorship of these devices is good, a substantial number of patients report dissatisfaction with the outcome of their procedure. Knowledge of in vivo kinematics and joint loading will enable improvement in preclinical assessment and refinement of implant geometry. The purpose of this investigation was to describe the mechanics of total knee arthroplasty during a variety of activities of daily living (gait, walking down stairs, and chair rise/sit). Estimates of muscle forces, tibial contact load, location, and pressure distribution was performed through a combination of mobile fluoroscopy data collection, musculoskeletal modeling, and finite element simulation. For the activities evaluated, joint compressive load was greatest during walking down stairs; however, the highest contact pressure occurred during chair rise/sit. The joint contact moment in the frontal plane was mainly varus for gait and walking down stairs, while it was valgus during chair rise/sit. Excursion of the center of pressure on the tibial component was similar during each activity and between the medial and lateral sides. The main determinants of center of pressure location were internal-external rotation, joint load, and tibial insert conformity. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1576-1587, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  11. Should the Ipsilateral Hamstrings Be Used for Anterior Cruciate Ligament Reconstruction in the Case of Medial Collateral Ligament Insufficiency? Biomechanical Investigation Regarding Dynamic Stabilization of the Medial Compartment by the Hamstring Muscles.

    PubMed

    Herbort, Mirco; Michel, Philipp; Raschke, Michael J; Vogel, Nils; Schulze, Martin; Zoll, Alexander; Fink, Christian; Petersen, Wolf; Domnick, Christoph

    2017-03-01

    Semitendinosus and gracilis muscles are frequently harvested for autologous tendon grafts for cruciate ligament reconstruction. This study investigated the joint-stabilizing effects of these hamstring muscles in cases of insufficiency of the medial collateral ligament (MCL). First, both the semitendinosus and gracilis muscles can actively stabilize the joint against valgus moments in the MCL-deficient knee. Second, the stabilizing influence of these muscles decreases with an increasing knee flexion angle. Controlled laboratory study. The kinematics was examined in 10 fresh-frozen human cadaveric knees using a robotic/universal force moment sensor system and an optical tracking system. The knee kinematics under 5- and 10-N·m valgus moments were determined in the different flexion angles of the (1) MCL-intact and (2) MCL-deficient knee using the following simulated muscle loads: (1) 0-N (idle) load, (2) 200-N semitendinosus (ST) load, and (3) 280-N (200/80-N) combined semitendinosus/gracilis (STGT) load. Cutting the MCL increased the valgus angle under all tested conditions and angles compared with the MCL-intact knee by 4.3° to 8.1° for the 5-N·m valgus moment and 6.5° to 11.9° for the 10-N·m valgus moment ( P < .01). The applied 200-N simulated ST load reduced the valgus angle significantly at 0°, 10°, 20°, and 30° of flexion under 5- and 10-N·m valgus moments ( P < .05). At 0°, 10°, and 20° of flexion, these values were close to those for the MCL-intact joint under the respective moments (both P > .05). The combined 280-N simulated STGT load significantly reduced the valgus angle in 0°, 10°, and 20° of flexion under 5- and 10-N·m valgus moments ( P < .05) to values near those for the intact joint (5 N·m: 0°, 10°; 10 N·m: 0°, 10°, 20°; P > .05). In 60° and 90° of flexion, ST and STGT loads did not decrease the resulting valgus angle of the MCL-deficient knee without hamstring loads ( P > .05 vs deficient; P = .0001 vs intact). In this human cadaveric study, semitendinosus and gracilis muscles successfully stabilize valgus moments applied to the MCL-insufficient knee when the knee is near extension. In the valgus-unstable knee, these data suggest that the hamstring muscles should be preserved in (multi-) ligament surgery when possible.

  12. Gait and balance of transfemoral amputees using passive mechanical and microprocessor-controlled prosthetic knees.

    PubMed

    Kaufman, K R; Levine, J A; Brey, R H; Iverson, B K; McCrady, S K; Padgett, D J; Joyner, M J

    2007-10-01

    Microprocessor-controlled knee joints appeared on the market a decade ago. These joints are more sophisticated and more expensive than mechanical ones. The literature is contradictory regarding changes in gait and balance when using these sophisticated devices. This study employed a crossover design to assess the comparative performance of a passive mechanical knee prosthesis compared to a microprocessor-controlled knee joint in 15 subjects with an above-knee amputation. Objective measurements of gait and balance were obtained. Subjects demonstrated significantly improved gait characteristics after receiving the microprocessor-controlled prosthetic knee joint (p<0.01). Improvements in gait were a transition from a hyperextended knee to a flexed knee during loading response which resulted in a change from an internal knee flexor moment to a knee extensor moment. The participants' balance also improved (p<0.01). All conditions of the Sensory Organization Test (SOT) demonstrated improvements in equilibrium score. The composite score also increased. Transfemoral amputees using a microprocessor-controlled knee have significant improvements in gait and balance.

  13. Posterior Tibial Slope Angle Correlates With Peak Sagittal and Frontal Plane Knee Joint Loading During Robotic Simulations of Athletic Tasks.

    PubMed

    Bates, Nathaniel A; Nesbitt, Rebecca J; Shearn, Jason T; Myer, Gregory D; Hewett, Timothy E

    2016-07-01

    Tibial slope angle is a nonmodifiable risk factor for anterior cruciate ligament (ACL) injury. However, the mechanical role of varying tibial slopes during athletic tasks has yet to be clinically quantified. To examine the influence of posterior tibial slope on knee joint loading during controlled, in vitro simulation of the knee joint articulations during athletic tasks. Descriptive laboratory study. A 6 degree of freedom robotic manipulator positionally maneuvered cadaveric knee joints from 12 unique specimens with varying tibial slopes (range, -7.7° to 7.7°) through drop vertical jump and sidestep cutting tasks that were derived from 3-dimensional in vivo motion recordings. Internal knee joint torques and forces were recorded throughout simulation and were linearly correlated with tibial slope. The mean (±SD) posterior tibial slope angle was 2.2° ± 4.3° in the lateral compartment and 2.3° ± 3.3° in the medial compartment. For simulated drop vertical jumps, lateral compartment tibial slope angle expressed moderate, direct correlations with peak internally generated knee adduction (r = 0.60-0.65), flexion (r = 0.64-0.66), lateral (r = 0.57-0.69), and external rotation torques (r = 0.47-0.72) as well as inverse correlations with peak abduction (r = -0.42 to -0.61) and internal rotation torques (r = -0.39 to -0.79). Only frontal plane torques were correlated during sidestep cutting simulations. For simulated drop vertical jumps, medial compartment tibial slope angle expressed moderate, direct correlations with peak internally generated knee flexion torque (r = 0.64-0.69) and lateral knee force (r = 0.55-0.74) as well as inverse correlations with peak external torque (r = -0.34 to -0.67) and medial knee force (r = -0.58 to -0.59). These moderate correlations were also present during simulated sidestep cutting. The investigation supported the theory that increased posterior tibial slope would lead to greater magnitude knee joint moments, specifically, internally generated knee adduction and flexion torques. The knee torques that positively correlated with increased tibial slope angle in this investigation are associated with heightened risk of ACL injury. Therefore, the present data indicated that a higher posterior tibial slope is correlated to increased knee loads that are associated with heightened risk of ACL injury. © 2016 The Author(s).

  14. Influence of a Full-Body Compression Suit on Trunk Positioning and Knee Joint Mechanics During Lateral Movements.

    PubMed

    Mornieux, Guillaume; Weltin, Elmar; Pauls, Monika; Rott, Franz; Gollhofer, Albert

    2017-08-01

    Trunk positioning has been shown to be associated with knee joint loading during athletic tasks, especially changes of direction. The purpose of the present study was to test whether a full-body compression suit (FBCS) would improve trunk positioning and knee joint control during lateral movements. Twelve female athletes performed lateral reactive jumps (LRJ) and unanticipated cuttings with and without the customized FBCS, while 3D kinematics and kinetics were measured. FBCS did not influence trunk positioning during LRJ and led to increased trunk lateral lean during cuttings (P < .001). However, while wearing FBCS, knee joint abduction and internal rotation angles were reduced during LRJ (P < .001 and P = .013, respectively), whereas knee joint moments were comparable during cuttings. FBCS cannot support the trunk segment during unanticipated dynamic movements. But, increased trunk lateral lean during cutting maneuvers was not high enough to elicit increased knee joint moments. On the contrary, knee joint abduction and internal rotation were reduced during LRJ, speaking for a better knee joint alignment with FBCS. Athletes seeking to improve trunk positioning may not benefit from a FBCS.

  15. Lower extremity joint loads in habitual rearfoot and mid/forefoot strike runners with normal and shortened stride lengths.

    PubMed

    Boyer, Elizabeth R; Derrick, Timothy R

    2018-03-01

    Our purpose was to compare joint loads between habitual rearfoot (hRF) and habitual mid/forefoot strikers (hFF), rearfoot (RFS) and mid/forefoot strike (FFS) patterns, and shorter stride lengths (SLs). Thirty-eight hRF and hFF ran at their normal SL, 5% and 10% shorter, as well as with the opposite foot strike. Three-dimensional ankle, knee, patellofemoral (PF) and hip contact forces were calculated. Nearly all contact forces decreased with a shorter SL (1.2-14.9% relative to preferred SL). In general, hRF had higher PF (hRF-RFS: 10.8 ± 1.4, hFF-FFS: 9.9 ± 2.0 BWs) and hip loads (axial hRF-RFS: -9.9 ± 0.9, hFF-FFS: -9.6 ± 1.0 BWs) than hFF. Many loads were similar between foot strike styles for the two groups, including axial and lateral hip, PF, posterior knee and shear ankle contact forces. Lateral knee and posterior hip contact forces were greater for RFS, and axial ankle and knee contact forces were greater for FFS. The tibia may be under greater loading with a FFS because of these greater axial forces. Summarising, a particular foot strike style does not universally decrease joint contact forces. However, shortening one's SL 10% decreased nearly all lower extremity contact forces, so it may hold potential to decrease overuse injuries associated with excessive joint loads.

  16. KNEE-JOINT LOADING IN KNEE OSTEOARTHRITIS: INFLUENCE OF ABDOMINAL AND THIGH FAT

    PubMed Central

    Messier, Stephen P.; Beavers, Daniel P.; Loeser, Richard F.; Carr, J. Jeffery; Khajanchi, Shubham; Legault, Claudine; Nicklas, Barbara J.; Hunter, David J.; DeVita, Paul

    2014-01-01

    Purpose Using three separate models that included total body mass, total lean and total fat mass, and abdominal and thigh fat as independent measures, we determined their association with knee-joint loads in older overweight and obese adults with knee osteoarthritis (OA). Methods Fat depots were quantified using computed tomography and total lean and fat mass determined with dual energy x-ray absorptiometry in 176 adults (age = 66.3 yr., BMI = 33.5 kg·m−2) with radiographic knee OA. Knee moments and joint bone-on-bone forces were calculated using gait analysis and musculoskeletal modeling. Results Higher total body mass was significantly associated (p ≤ 0.0001) with greater knee compressive and shear forces, compressive and shear impulses (p < 0.0001), patellofemoral forces (p< 0.006), and knee extensor moments (p = 0.003). Regression analysis with total lean and total fat mass as independent variables revealed significant positive associations of total fat mass with knee compressive (p = 0.0001), shear (p < 0.001), and patellofemoral forces (p = 0.01) and knee extension moment (p = 0.008). Gastrocnemius and quadriceps forces were positively associated with total fat mass. Total lean mass was associated with knee compressive force (p = 0.002). A regression model that included total thigh and total abdominal fat found both were significantly associated with knee compressive and shear forces (p ≤ 0.04). Thigh fat was associated with the knee abduction (p = 0.03) and knee extension moment (p = 0.02). Conclusions Thigh fat, consisting predominately of subcutaneous fat, had similar significant associations with knee joint forces as abdominal fat despite its much smaller volume and could be an important therapeutic target for people with knee OA. PMID:25133996

  17. Knee joint loading in knee osteoarthritis: influence of abdominal and thigh fat.

    PubMed

    Messier, Stephen P; Beavers, Daniel P; Loeser, Richard F; Carr, J Jeffery; Khajanchi, Shubham; Legault, Claudine; Nicklas, Barbara J; Hunter, David J; Devita, Paul

    2014-09-01

    Using three separate models that included total body mass, total lean and total fat mass, and abdominal and thigh fat as independent measures, we determined their association with knee joint loads in older overweight and obese adults with knee osteoarthritis (OA). Fat depots were quantified using computed tomography, and total lean and fat mass were determined with dual energy x-ray absorptiometry in 176 adults (age, 66.3 yr; body mass index, 33.5 kg·m) with radiographic knee OA. Knee moments and joint bone-on-bone forces were calculated using gait analysis and musculoskeletal modeling. Higher total body mass was significantly associated (P ≤ 0.0001) with greater knee compressive and shear forces, compressive and shear impulses (P < 0.0001), patellofemoral forces (P < 0.006), and knee extensor moments (P = 0.003). Regression analysis with total lean and total fat mass as independent variables revealed significant positive associations of total fat mass with knee compressive (P = 0.0001), shear (P < 0.001), and patellofemoral forces (P = 0.01) and knee extension moment (P = 0.008). Gastrocnemius and quadriceps forces were positively associated with total fat mass. Total lean mass was associated with knee compressive force (P = 0.002). A regression model that included total thigh and total abdominal fat found that both were significantly associated with knee compressive and shear forces (P ≤ 0.04). Thigh fat was associated with knee abduction (P = 0.03) and knee extension moment (P = 0.02). Thigh fat, consisting predominately of subcutaneous fat, had similar significant associations with knee joint forces as abdominal fat despite its much smaller volume and could be an important therapeutic target for people with knee OA.

  18. Dual-joint modeling for estimation of total knee replacement contact forces during locomotion.

    PubMed

    Hast, Michael W; Piazza, Stephen J

    2013-02-01

    Model-based estimation of in vivo contact forces arising between components of a total knee replacement is challenging because such forces depend upon accurate modeling of muscles, tendons, ligaments, contact, and multibody dynamics. Here we describe an approach to solving this problem with results that are tested by comparison to knee loads measured in vivo for a single subject and made available through the Grand Challenge Competition to Predict in vivo Tibiofemoral Loads. The approach makes use of a "dual-joint" paradigm in which the knee joint is alternately represented by (1) a ball-joint knee for inverse dynamic computation of required muscle controls and (2) a 12 degree-of-freedom (DOF) knee with elastic foundation contact at the tibiofemoral and patellofemoral articulations for forward dynamic integration. Measured external forces and kinematics were applied as a feedback controller and static optimization attempted to track measured knee flexion angles and electromyographic (EMG) activity. The resulting simulations showed excellent tracking of knee flexion (average RMS error of 2.53 deg) and EMG (muscle activations within ±10% envelopes of normalized measured EMG signals). Simulated tibiofemoral contact forces agreed qualitatively with measured contact forces, but their RMS errors were approximately 25% of the peak measured values. These results demonstrate the potential of a dual-joint modeling approach to predict joint contact forces from kinesiological data measured in the motion laboratory. It is anticipated that errors in the estimation of contact force will be reduced as more accurate subject-specific models of muscles and other soft tissues are developed.

  19. Effects of Lateral and Medial Wedged Insoles on Knee and Ankle Internal Joint Moments During Walking in Healthy Men.

    PubMed

    Fukuchi, Claudiane A; Lewinson, Ryan T; Worobets, Jay T; Stefanyshyn, Darren J

    2016-11-01

    Wedged insoles have been used to treat knee pathologies and to prevent injuries. Although they have received much attention for the study of knee injury, the effects of wedges on ankle joint biomechanics are not well understood. This study sought to evaluate the immediate effects of lateral and medial wedges on knee and ankle internal joint loading and center of pressure (CoP) in men during walking. Twenty-one healthy men walked at 1.4 m/sec in five footwear conditions: neutral, 6° (LW6) and 9° (LW9) lateral wedges, and 6° (MW6) and 9° (MW9) medial wedges. Peak internal knee abduction moments and angular impulses, internal ankle inversion moments and angular impulses, and mediolateral CoP were analyzed. Analysis of variance with post hoc analysis and Pearson correlations were performed to detect differences between conditions. No differences in internal knee joint loading were found between neutral and any of the wedge conditions. However, as the wedge angle increased from medial to lateral, the internal ankle inversion moment (LW6: P = .020; LW9: P < .001; MW6: P = .046; MW9: P < .001) and angular impulse (LW9: P = .012) increased, and the CoP shifted laterally (LW9: P < .001) and medially (MW9: P < .001) compared with the neutral condition. Neither lateral nor medial wedges were effective in altering internal knee joint loading during walking. However, the greater internal ankle inversion moment and angular impulse observed with lateral wedges could lead to a higher risk of ankle injury. Thus, caution should be taken when lateral wedges need to be prescribed.

  20. Influences of Patellofemoral Pain and Fatigue in Female Dancers during Ballet Jump-Landing.

    PubMed

    Peng, H-T; Chen, W C; Kernozek, T W; Kim, K; Song, C-Y

    2015-08-01

    This study investigated the influence of patellofemoral pain (PFP) and fatigue on lower-extremity joint biomechanics in female dancers during consecutive simple ground échappé. 3-dimensional joint mechanics were analyzed from the no-fatigue to fatigue conditions. 2-way mixed ANOVAs were used to compare the differences of the kinematic and kinetic variables between groups and conditions. Group main effects were seen in increased jump height (p=0.03), peak vertical ground reaction force (p=0.01), knee joint power absorption (p=0.04), and patellofemoral joint stress (PFJS, p=0.04) for PFP group. Fatigue main effects were found for decreased jump height (p<0.01), decreased ankle plantarflexion at initial foot-ground contact (p=0.01), and decreased ankle displacement (p<0.01). Hip external rotation impulse and hip joint stiffness increased (both p<0.01) while knee extension and external rotation moment, and ankle joint power absorption decreased (p<0.01, p=0.02, p<0.01, respectively) after fatigue. The peak PFJS also decreased after fatigue (p<0.01). Female ballet dancers with PFP sustained great ground impact and loads on the knee probably due to higher jump height compared to the controls. All dancers presented diminished knee joint loading for the protective mechanism and endurance of ankle joint musculature required for the dissipation of loads and displayed a distal-to-proximal dissipation strategy after fatigue. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Femoral condyle curvature is correlated with knee walking kinematics in ungulates.

    PubMed

    Sylvester, Adam D

    2015-12-01

    The knee has been the focus of many studies linking mammalian postcranial form with locomotor behaviors and animal ecology. A more difficult task has been linking joint morphology with joint kinematics during locomotor tasks. Joint curvature represents one opportunity to link postcranial morphology with walking kinematics because joint curvature develops in response to mechanical loading. As an initial examination of mammalian knee joint curvature, the curvature of the medial femoral condyle was measured on femora representing 11 ungulate species. The position of a region of low curvature was measured using a metric termed the "angle to low curvature". This low-curvature region is important because it provides the greatest contact area between femoral and tibial condyles. Kinematic knee angles during walking were derived from the literature and kinematic knee angles across the gait cycle were correlated with angle to low curvature values. The highest correlation between kinematic knee angle and the angle to low curvature metric occurred at 20% of the walking gait cycle. This early portion of the walking gait cycle is associated with a peak in the vertical ground reaction force for some mammals. The chondral modeling theory predicts that frequent and heavy loading of particular regions of a joint surface during ontogeny will result in these regions being flatter than the surrounding joint surface. The locations of flatter regions of the femoral condyles of ungulates, and their association with knee angles used during the early stance phase of walking provides support for the chondral modeling theory. © 2015 Wiley Periodicals, Inc.

  2. Reductions in knee joint forces with weight loss are attenuated by gait adaptations in class III obesity.

    PubMed

    DeVita, Paul; Rider, Patrick; Hortobágyi, Tibor

    2016-03-01

    A consensus exists that high knee joint forces are a precursor to knee osteoarthritis and weight loss reduces these forces. Because large weight loss also leads to increased step length and walking velocity, knee contact forces may be reduced less than predicted by the magnitude of weight loss. The purpose was to determine the effects of weight loss on knee muscle and joint loads during walking in Class III obese adults. We determined through motion capture, force platform measures and biomechanical modeling the effects of weight loss produced by gastric bypass surgery over one year on knee muscle and joint loads during walking at a standard, controlled velocity and at self-selected walking velocities. Weight loss equaling 412 N or 34% of initial body weight reduced maximum knee compressive force by 824 N or 67% of initial body weight when walking at the controlled velocity. These changes represent a 2:1 reduction in knee force relative to weight loss when walking velocity is constrained to the baseline value. However, behavioral adaptations including increased stride length and walking velocity in the self-selected velocity condition attenuated this effect by ∼50% leading to a 392 N or 32% initial body weight reduction in compressive force in the knee joint. Thus, unconstrained walking elicited approximately 1:1 ratio of reduction in knee force relative to weight loss and is more indicative of walking behavior than the standard velocity condition. In conclusion, massive weight loss produces dramatic reductions in knee forces during walking but when patients stride out and walk faster, these favorable reductions become substantially attenuated. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Influence of meniscus shape in the cross sectional plane on the knee contact mechanics.

    PubMed

    Łuczkiewicz, Piotr; Daszkiewicz, Karol; Witkowski, Wojciech; Chróścielewski, Jacek; Zarzycki, Witold

    2015-06-01

    We present a three dimensional finite element analysis of stress distribution and menisci deformation in the human knee joint. The study is based on the Open Knee model with the geometry of the lateral meniscus which shows some degenerative disorders. The nonlinear analysis of the knee joint under compressive axial load is performed. We present results for intact knee, knee with complete radial posterior meniscus root tear and knee with total meniscectomy of medial or lateral meniscus. We investigate how the meniscus shape in the cross sectional plane influences knee-joint mechanics by comparing the results for flat (degenerated) lateral and normal medial meniscus. Specifically, the deformation of the menisci in the coronal plane and the corresponding stress values in cartilages are studied. By analysing contact resultant force acting on the menisci in axial plane we have shown that restricted extrusion of the torn lateral meniscus can be attributed to small slope of its cross section in the coronal plane. Additionally, the change of the contact area and the resultant force acting on the menisci as the function of compressive load are investigated. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Mechanical and biomechanical analysis of a linear piston design for angular-velocity-based orthotic control.

    PubMed

    Lemaire, Edward D; Samadi, Reza; Goudreau, Louis; Kofman, Jonathan

    2013-01-01

    A linear piston hydraulic angular-velocity-based control knee joint was designed for people with knee-extensor weakness to engage knee-flexion resistance when knee-flexion angular velocity reaches a preset threshold, such as during a stumble, but to otherwise allow free knee motion. During mechanical testing at the lowest angular-velocity threshold, the device engaged within 2 degrees knee flexion and resisted moment loads of over 150 Nm. The device completed 400,000 loading cycles without mechanical failure or wear that would affect function. Gait patterns of nondisabled participants were similar to normal at walking speeds that produced below-threshold knee angular velocities. Fast walking speeds, employed purposely to attain the angular-velocity threshold and cause knee-flexion resistance, reduced maximum knee flexion by approximately 25 degrees but did not lead to unsafe gait patterns in foot ground clearance during swing. In knee collapse tests, the device successfully engaged knee-flexion resistance and stopped knee flexion with peak knee moments of up to 235.6 Nm. The outcomes from this study support the potential for the linear piston hydraulic knee joint in knee and knee-ankle-foot orthoses for people with lower-limb weakness.

  5. The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement.

    PubMed

    Smith, Colin R; Vignos, Michael F; Lenhart, Rachel L; Kaiser, Jarred; Thelen, Darryl G

    2016-02-01

    The study objective was to investigate the influence of coronal plane alignment and ligament properties on total knee replacement (TKR) contact loads during walking. We created a subject-specific knee model of an 83-year-old male who had an instrumented TKR. The knee model was incorporated into a lower extremity musculoskeletal model and included deformable contact, ligamentous structures, and six degrees-of-freedom (DOF) tibiofemoral and patellofemoral joints. A novel numerical optimization technique was used to simultaneously predict muscle forces, secondary knee kinematics, ligament forces, and joint contact pressures from standard gait analysis data collected on the subject. The nominal knee model predictions of medial, lateral, and total contact forces during gait agreed well with TKR measures, with root-mean-square (rms) errors of 0.23, 0.22, and 0.33 body weight (BW), respectively. Coronal plane component alignment did not affect total knee contact loads, but did alter the medial-lateral load distribution, with 4 deg varus and 4 deg valgus rotations in component alignment inducing +17% and -23% changes in the first peak medial tibiofemoral contact forces, respectively. A Monte Carlo analysis showed that uncertainties in ligament stiffness and reference strains induce ±0.2 BW uncertainty in tibiofemoral force estimates over the gait cycle. Ligament properties had substantial influence on the TKR load distributions, with the medial collateral ligament and iliotibial band (ITB) properties having the largest effects on medial and lateral compartment loading, respectively. The computational framework provides a viable approach for virtually designing TKR components, considering parametric uncertainty and predicting the effects of joint alignment and soft tissue balancing procedures on TKR function during movement.

  6. The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement

    PubMed Central

    Smith, Colin R.; Vignos, Michael F.; Lenhart, Rachel L.; Kaiser, Jarred; Thelen, Darryl G.

    2016-01-01

    The study objective was to investigate the influence of coronal plane alignment and ligament properties on total knee replacement (TKR) contact loads during walking. We created a subject-specific knee model of an 83-year-old male who had an instrumented TKR. The knee model was incorporated into a lower extremity musculoskeletal model and included deformable contact, ligamentous structures, and six degrees-of-freedom (DOF) tibiofemoral and patellofemoral joints. A novel numerical optimization technique was used to simultaneously predict muscle forces, secondary knee kinematics, ligament forces, and joint contact pressures from standard gait analysis data collected on the subject. The nominal knee model predictions of medial, lateral, and total contact forces during gait agreed well with TKR measures, with root-mean-square (rms) errors of 0.23, 0.22, and 0.33 body weight (BW), respectively. Coronal plane component alignment did not affect total knee contact loads, but did alter the medial–lateral load distribution, with 4 deg varus and 4 deg valgus rotations in component alignment inducing +17% and −23% changes in the first peak medial tibiofemoral contact forces, respectively. A Monte Carlo analysis showed that uncertainties in ligament stiffness and reference strains induce ±0.2 BW uncertainty in tibiofemoral force estimates over the gait cycle. Ligament properties had substantial influence on the TKR load distributions, with the medial collateral ligament and iliotibial band (ITB) properties having the largest effects on medial and lateral compartment loading, respectively. The computational framework provides a viable approach for virtually designing TKR components, considering parametric uncertainty and predicting the effects of joint alignment and soft tissue balancing procedures on TKR function during movement. PMID:26769446

  7. Effects of step rate manipulation on joint mechanics during running.

    PubMed

    Heiderscheit, Bryan C; Chumanov, Elizabeth S; Michalski, Max P; Wille, Christa M; Ryan, Michael B

    2011-02-01

    the objective of this study was to characterize the biomechanical effects of step rate modification during running on the hip, knee, and ankle joints so as to evaluate a potential strategy to reduce lower extremity loading and risk for injury. three-dimensional kinematics and kinetics were recorded from 45 healthy recreational runners during treadmill running at constant speed under various step rate conditions (preferred, ± 5%, and ± 10%). We tested our primary hypothesis that a reduction in energy absorption by the lower extremity joints during the loading response would occur, primarily at the knee, when step rate was increased. less mechanical energy was absorbed at the knee (P < 0.01) during the +5% and +10% step rate conditions, whereas the hip (P < 0.01) absorbed less energy during the +10% condition only. All joints displayed substantially (P < 0.01) more energy absorption when preferred step rate was reduced by 10%. Step length (P < 0.01), center of mass vertical excursion (P < 0.01), braking impulse (P < 0.01), and peak knee flexion angle (P < 0.01) were observed to decrease with increasing step rate. When step rate was increased 10% above preferred, peak hip adduction angle (P < 0.01) and peak hip adduction (P < 0.01) and internal rotation (P < 0.01) moments were found to decrease. we conclude that subtle increases in step rate can substantially reduce the loading to the hip and knee joints during running and may prove beneficial in the prevention and treatment of common running-related injuries.

  8. Lower limb flexion posture relates to energy absorption during drop landings with soldier-relevant body borne loads.

    PubMed

    Brown, T N; O'Donovan, M; Hasselquist, L; Corner, B; Schiffman, J M

    2016-01-01

    Fifteen military personnel performed 30-cm drop landings to quantify how body borne load (light, ∼6 kg, medium, ∼20 kg, and heavy, ∼40 kg) impacts lower limb kinematics and knee joint energy absorption during landing, and determine whether greater lower limb flexion increases energy absorption while landing with load. Participants decreased peak hip (P = 0.002), and knee flexion (P = 0.007) posture, but did not increase hip (P = 0.796), knee (P = 0.427) or ankle (P = 0.161) energy absorption, despite exhibiting greater peak hip (P = 0.003) and knee (P = 0.001) flexion, and ankle (P = 0.003) dorsiflexion angular impulse when landing with additional load. Yet, when landing with the light and medium loads, greater hip (R(2) = 0.500, P = 0.003 and R(2) = 0.314, P = 0.030) and knee (R(2) = 0.431, P = 0.008 and R(2) = 0.342, P = 0.022) flexion posture predicted larger knee joint energy absorption. Thus, military training that promotes hip and knee flexion, and subsequently greater energy absorption during landing, may potentially reduce risk of musculoskeletal injury and optimize soldier performance. Published by Elsevier Ltd.

  9. Direct measurement of hoop strains in the intact and torn human medial meniscus.

    PubMed

    Jones, R Spencer; Keene, G C R; Learmonth, D J A; Bickerstaff, D; Nawana, N S; Costi, J J; Pearcy, M J

    1996-07-01

    OBJECTIVE: To measure the circumferential or hoop strains generated in the medial meniscus during loading of the knee joint and to examine the effect of longitudinal and radial tears in the meniscus on these strain values. DESIGN: An in vitro investigation measuring the circumferential strains in the medial menisci of cadaveric human knees as they were loaded in a materials testing machine. BACKGROUND: The menisci transmit approximately 50% of the load through the knee, the rest being transmitted by direct contact of the articular cartilage. Damage to the menisci will alter the pattern of load transmission as will meniscectomy. This study examined the changes in the mechanics of the meniscus in situ as a result of simulated tears to assess the effect of its load carrying capacity and the implications of surgery to remove part or all of a damaged meniscus. METHODS: Nineteen human cadaveric knees were tested. Windows were made in the joint capsule and strain gauges inserted into the anterior, middle and posterior sections of the medial meniscus. The knees were then loaded to three times body weight at speeds of 50 and 500 mm/min, with the knee joint at 0 degrees and 30 degrees of flexion. The tests were repeated following the creation of a longitudinal or a radial tear in the meniscus. RESULTS: The intact menisci showed significantly less strain in the posterior section compared to the anterior and middle sections (P < 0.003, with strains of 1.54%, 2.86% and 2.65% respectively). With a longitudinal tear this pattern changed with strains decreasing anteriorly and increasing posteriorly. There were also significant differences at different angles of knee joint flexion not seen in the intact meniscus. 50% radial tears reduced the strains anteriorly whilst a complete radial tear completely defunctioned the meniscus. CONCLUSIONS: This study has shown that there are significantly different hoop strains produced in different sections of the medial meniscus under load and the patterns of strain distribution are disturbed by meniscal tears. RELEVANCE: These results provide important data for mathematical models which must include non-uniform behaviour. They also have implications for the surgical management of torn menisci. Undamaged portions should be preserved and the integrity of the circumferential fibres maintained to ensure the menisci retain a load bearing capability.

  10. Meniscal Preservation is Important for the Knee Joint

    PubMed Central

    Patil, Shantanu Sudhakar; Shekhar, Anshu; Tapasvi, Sachin Ramchandra

    2017-01-01

    Native joint preservation has gained importance in recent years. This is mostly to find solutions for limitations of arthroplasty. In the knee joint, the menisci perform critical functions, adding stability during range of motion and efficiently transferring load across the tibiofemoral articulation while protecting the cartilage. The menisci are the most common injury seen by orthopedicians, especially in the younger active patients. Advances in technology and our knowledge on functioning of the knee joint have made meniscus repair an important mode of treatment. This review summarizes the various techniques of meniscus tear repair and also describes biological enhancements of healing. PMID:28966381

  11. Gait Mechanics in Those With/Without Medial Compartment Knee Osteoarthritis 5 Years After Anterior Cruciate Ligament Reconstruction

    PubMed Central

    Khandha, Ashutosh; Manal, Kurt; Wellsandt, Elizabeth; Capin, Jacob; Snyder-Mackler, Lynn; Buchanan, Thomas S.

    2016-01-01

    The objective of the study was to evaluate differences in gait mechanics 5 years after unilateral anterior cruciate ligament reconstruction surgery, for non-osteoarthritic (n = 24) versus osteoarthritic (n = 9) subjects. For the involved knee, the osteoarthritic group demonstrated significantly lower peak knee flexion angles (non-osteoarthritic = 24.3 ± 4.6°, osteoarthritic = 19.1 ± 2.9°, p = 0.01) and peak knee flexion moments (non-osteoarthritic = 5.3 ± 1.2% Body Weight × Height, osteoarthritic = 4.4 ± 1.2% Body Weight × Height, p = 0.05). Differences in peak knee adduction moment approached significance, with a higher magnitude for the osteoarthritic group (non-osteoarthritic = 2.4 ±0.8% Body Weight × Height, osteoarthritic = 2.9 ± 0.5% Body Weight × Height, p = 0.09). Peak medial compartment joint load was evaluated using electromyography-informed neuromusculoskeletal modeling. Peak medial compartment joint load in the involved knee for the two groups was not different (non-osteoarthritic = 2.4 ± 0.4 Body Weight, osteoarthritic = 2.3 ± 0.6 Body Weight). The results suggest that subjects with dissimilar peak knee moments can have similar peak medial compartment joint load magnitudes. There was no evidence of inter-limb asymmetry for either group. Given the presence of inter-group differences (non-osteoarthritic vs. osteoarthritic) for the involved knee, but an absence of inter-limb asymmetry in either group, it may be necessary to evaluate how symmetry is achieved, over time, and to differentiate between good versus bad inter-limb symmetry, when evaluating knee gait parameters. PMID:27082166

  12. Occupational Physical Loading Tasks and Knee Osteoarthritis: A Review of the Evidence

    PubMed Central

    Ezzat, Allison M.

    2014-01-01

    ABSTRACT Purpose: To perform a systematic review with best evidence synthesis examining the literature on the relationship between occupational loading tasks and knee osteoarthritis (OA). Methods: Two databases were searched to identify articles published between 1946 and April, 2011. Eligible studies were those that (1) included adults reporting on their employment history; (2) measured individuals' exposure to work-related activities with heavy loading in the knee joint; and (3) identified presence of knee OA (determined by X-ray), cartilage defects associated with knee OA (identified by magnetic resonance imaging), or joint replacement surgery. Results: A total of 32 articles from 31 studies met the inclusion criteria. We found moderate evidence that combined heavy lifting and kneeling is a risk factor for knee OA, with odds ratios (OR) varying from 1.8 to 7.9, and limited evidence for heavy lifting (OR=1.4–7.3), kneeling (OR=1.5–6.9), stair climbing (OR=1.6–5.1), and occupational groups (OR=1.4–4.7) as risk factors. When examined by sex, moderate level evidence of knee OA was found in men; however, the evidence in women was limited. Conclusions: Further high-quality prospective studies are warranted to provide further evidence on the role of occupational loading tasks in knee OA, particularly in women. PMID:24719516

  13. Joint torques and joint reaction forces during squatting with a forward or backward inclined Smith machine.

    PubMed

    Biscarini, Andrea; Botti, Fabio M; Pettorossi, Vito E

    2013-02-01

    We developed a biomechanical model to determine the joint torques and loadings during squatting with a backward/forward-inclined Smith machine. The Smith squat allows a large variety of body positioning (trunk tilt, foot placement, combinations of joint angles) and easy control of weight distribution between forefoot and heel. These distinctive aspects of the exercise can be managed concurrently with the equipment inclination selected to unload specific joint structures while activating specific muscle groups. A backward (forward) equipment inclination decreases (increases) knee torque, and compressive tibiofemoral and patellofemoral forces, while enhances (depresses) hip and lumbosacral torques. For small knee flexion angles, the strain-force on the posterior cruciate ligament increases (decreases) with a backward (forward) equipment inclination, whereas for large knee flexion angles, this behavior is reversed. In the 0 to 60 degree range of knee flexion angles, loads on both cruciate ligaments may be simultaneously suppressed by a 30 degree backward equipment inclination and selecting, for each value of the knee angle, specific pairs of ankle and hip angles. The anterior cruciate ligament is safely maintained unloaded by squatting with backward equipment inclination and uniform/forward foot weight distribution. The conditions for the development of anterior cruciate ligament strain forces are clearly explained.

  14. Modelling the joint torques and loadings during squatting at the Smith machine.

    PubMed

    Biscarini, Andrea; Benvenuti, Paolo; Botti, Fabio; Mastrandrea, Francesco; Zanuso, Silvano

    2011-03-01

    An analytical biomechanical model was developed to establish the relevant properties of the Smith squat exercise, and the main differences from the free barbell squat. The Smith squat may be largely patterned to modulate the distributions of muscle activities and joint loadings. For a given value of the included knee angle (θ(knee)), bending the trunk forward, moving the feet forward in front of the knees, and displacing the weight distribution towards the forefoot emphasizes hip and lumbosacral torques, while also reducing knee torque and compressive tibiofemoral and patellofemoral forces (and vice versa). The tibiofemoral shear force φ(t) displays more complex trends that strongly depend on θ(knee). Notably, for 180° ≥ θ(knee) ≥ 130°, φ(t) and cruciate ligament strain forces can be suppressed by selecting proper pairs of ankle and hip angles. Loading of the posterior cruciate ligament increases (decreases) in the range 180° ≥ θ(knee) ≥ 150° (θ(knee) ≤ 130°) with knee extension, bending the trunk forward, and moving the feet forward in front of the knees. In the range 150° > θ(knee) > 130°, the behaviour changes depending on the foot weight distribution. The conditions for the development of anterior cruciate ligament strain forces are explained. This work enables careful use of the Smith squat in strengthening and rehabilitation programmes.

  15. Preservation of kinematics with posterior cruciate-, bicruciate- and patient-specific bicruciate-retaining prostheses in total knee arthroplasty by using computational simulation with normal knee model

    PubMed Central

    Koh, Y-G.; Son, J.; Kwon, S-K.; Kim, H-J.; Kang, K-T.

    2017-01-01

    Objectives Preservation of both anterior and posterior cruciate ligaments in total knee arthroplasty (TKA) can lead to near-normal post-operative joint mechanics and improved knee function. We hypothesised that a patient-specific bicruciate-retaining prosthesis preserves near-normal kinematics better than standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining prostheses in TKA. Methods We developed the validated models to evaluate the post-operative kinematics in patient-specific bicruciate-retaining, standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under gait and deep knee bend loading conditions using numerical simulation. Results Tibial posterior translation and internal rotation in patient-specific bicruciate-retaining prostheses preserved near-normal kinematics better than other standard off-the-shelf prostheses under gait loading conditions. Differences from normal kinematics were minimised for femoral rollback and internal-external rotation in patient-specific bicruciate-retaining, followed by standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under deep knee bend loading conditions. Moreover, the standard off-the-shelf posterior cruciate-retaining TKA in this study showed the most abnormal performance in kinematics under gait and deep knee bend loading conditions, whereas patient-specific bicruciate-retaining TKA led to near-normal kinematics. Conclusion This study showed that restoration of the normal geometry of the knee joint in patient-specific bicruciate-retaining TKA and preservation of the anterior cruciate ligament can lead to improvement in kinematics compared with the standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining TKA. Cite this article: Y-G. Koh, J. Son, S-K. Kwon, H-J. Kim, O-R. Kwon, K-T. Kang. Preservation of kinematics with posterior cruciate-, bicruciate- and patient-specific bicruciate-retaining prostheses in total knee arthroplasty by using computational simulation with normal knee model. Bone Joint Res 2017;6:557–565. DOI: 10.1302/2046-3758.69.BJR-2016-0250.R1. PMID:28947604

  16. Decreased Knee Joint Loading Associated With Early Knee Osteoarthritis After Anterior Cruciate Ligament Injury.

    PubMed

    Wellsandt, Elizabeth; Gardinier, Emily S; Manal, Kurt; Axe, Michael J; Buchanan, Thomas S; Snyder-Mackler, Lynn

    2016-01-01

    Anterior cruciate ligament (ACL) injury predisposes individuals to early-onset knee joint osteoarthritis (OA). Abnormal joint loading is apparent after ACL injury and reconstruction. The relationship between altered joint biomechanics and the development of knee OA is unknown. Altered knee joint kinetics and medial compartment contact forces initially after injury and reconstruction are associated with radiographic knee OA 5 years after reconstruction. Case-control study; Level of evidence, 3. Individuals with acute, unilateral ACL injury completed gait analysis before (baseline) and after (posttraining) preoperative rehabilitation and at 6 months, 1 year, and 2 years after reconstruction. Surface electromyographic and knee biomechanical data served as inputs to an electromyographically driven musculoskeletal model to estimate knee joint contact forces. Patients completed radiographic testing 5 years after reconstruction. Differences in knee joint kinetics and contact forces were compared between patients with and those without radiographic knee OA. Patients with OA walked with greater frontal plane interlimb differences than those without OA (nonOA) at baseline (peak knee adduction moment difference: 0.00 ± 0.08 N·m/kg·m [nonOA] vs -0.15 ± 0.09 N·m/kg·m [OA], P = .014; peak knee adduction moment impulse difference: -0.001 ± 0.032 N·m·s/kg·m [nonOA] vs -0.048 ± 0.031 N·m·s/kg·m [OA], P = .042). The involved limb knee adduction moment impulse of the group with osteoarthritis was also lower than that of the group without osteoarthritis at baseline (0.087 ± 0.023 N·m·s/kg·m [nonOA] vs 0.049 ± 0.018 N·m·s/kg·m [OA], P = .023). Significant group differences were absent at posttraining but reemerged 6 months after reconstruction (peak knee adduction moment difference: 0.02 ± 0.04 N·m/kg·m [nonOA] vs -0.06 ± 0.11 N·m/kg·m [OA], P = .043). In addition, the OA group walked with lower peak medial compartment contact forces of the involved limb than did the group without OA at 6 months (2.89 ± 0.52 body weight [nonOA] vs 2.10 ± 0.69 body weight [OA], P = .036). Patients who had radiographic knee OA 5 years after ACL reconstruction walked with lower knee adduction moments and medial compartment joint contact forces than did those patients without OA early after injury and reconstruction. © 2015 The Author(s).

  17. Decreased Knee Joint Loading Associated With Early Knee Osteoarthritis After Anterior Cruciate Ligament Injury

    PubMed Central

    Wellsandt, Elizabeth; Gardinier, Emily S.; Manal, Kurt; Axe, Michael J.; Buchanan, Thomas S.; Snyder-Mackler, Lynn

    2015-01-01

    Background Anterior cruciate ligament (ACL) injury predisposes individuals to early-onset knee joint osteoarthritis (OA). Abnormal joint loading is apparent after ACL injury and reconstruction. The relationship between altered joint biomechanics and the development of knee OA is unknown. Hypothesis Altered knee joint kinetics and medial compartment contact forces initially after injury and reconstruction are associated with radiographic knee OA 5 years after reconstruction. Study Design Case-control study; Level of evidence, 3. Methods Individuals with acute, unilateral ACL injury completed gait analysis before (baseline) and after (posttraining) preoperative rehabilitation and at 6 months, 1 year, and 2 years after reconstruction. Surface electromyographic and knee biomechanical data served as inputs to an electromyographically driven musculoskeletal model to estimate knee joint contact forces. Patients completed radiographic testing 5 years after reconstruction. Differences in knee joint kinetics and contact forces were compared between patients with and those without radiographic knee OA. Results Patients with OA walked with greater frontal plane interlimb differences than those without OA (nonOA) at baseline (peak knee adduction moment difference: 0.00 ± 0.08 N·m/kg·m [nonOA] vs −0.15 ± 0.09 N·m/kg·m [OA], P = .014; peak knee adduction moment impulse difference: −0.001 ± 0.032 N·m·s/kg·m [nonOA] vs −0.048 ± 0.031 N·m·s/kg·m [OA], P = .042). The involved limb knee adduction moment impulse of the group with osteoarthritis was also lower than that of the group without osteoarthritis at baseline (0.087 ± 0.023 N·m·s/kg·m [nonOA] vs 0.049 ± 0.018 N·m·s/kg·m [OA], P = .023). Significant group differences were absent at posttraining but reemerged 6 months after reconstruction (peak knee adduction moment difference: 0.02 ± 0.04 N·m/kg·m [nonOA] vs −0.06 ± 0.11 N·m/kg·m [OA], P = .043). In addition, the OA group walked with lower peak medial compartment contact forces of the involved limb than did the group without OA at 6 months (2.89 ± 0.52 body weight [nonOA] vs 2.10 ± 0.69 body weight [OA], P = .036). Conclusion Patients who had radiographic knee OA 5 years after ACL reconstruction walked with lower knee adduction moments and medial compartment joint contact forces than did those patients without OA early after injury and reconstruction. PMID:26493337

  18. Relationships between the center of pressure and the movements of the ankle and knee joints during the stance phase in patients with severe medial knee osteoarthritis.

    PubMed

    Fukaya, Takashi; Mutsuzaki, Hirotaka; Okubo, Tomoyuki; Mori, Koichi; Wadano, Yasuyoshi

    2016-08-01

    The knee joint movement during the stance phase is affected by altered ankle movement and the center of pressure (COP). However the relationships between changes in the center of pressure (COP) and the altered kinematics and kinetics of the ankle and knee joints in patients with osteoarthritis (OA) of the knee are not well understood. The purpose of this study was to determine the relationships between changes in the COP and the altered kinematic and kinetic variables in ankle and knee joints during the stance phase in patients with medial knee OA. Fourteen patients with knee OA (21 knees) and healthy subjects were assessed by gait analysis using an eight-camera motion analysis system to record forward and lateral shifts in the COP and the angle and net internal moments of the knee and ankle joint. Spearman rank-correlation coefficients were used to determine the relationship between these results. In knees with medial OA, lateral shifts in the COP were correlated with knee flexion angle. Lateral shifts in the COP were correlated with the second peak of the knee extensor moment and correlated with the knee abductor moment. In patients with medial knee OA, lateral shifts in the COP were negatively correlated with the kinematic and kinetic variables in the sagittal plane of the knee joints. Controlling such lateral shifts in the COP may thus be an effective intervention for mechanical loads on the knee during the stance phase in patients with knee OA. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Load Sharing Among Collateral Ligaments, Articular Surfaces, and the Tibial Post in Constrained Condylar Knee Arthroplasty.

    PubMed

    Wang, Xiaonan; Malik, Aamer; Bartel, Donald L; Wright, Timothy M; Padgett, Douglas E

    2016-08-01

    The normal knee joint maintains stable motion during activities of daily living. After total knee arthroplasty (TKA), stability is achieved by the conformity of the bearing surfaces of the implant components, ligaments, and constraint structures incorporated in the implant design. The large, rectangular tibial post in constrained condylar knee (CCK) arthroplasty, often used in revision surgery, provides added stability, but increases susceptibility to polyethylene wear as it contacts the intercondylar box on the femoral component. We examined coronal plane stability to understand the relative contributions of the mechanisms that act to stabilize the CCK knee under varus-valgus loading, namely, load distribution between the medial and lateral condyles, contact of the tibial post with the femoral intercondylar box, and elongation of the collateral ligaments. A robot testing system was used to determine the joint stability in human cadaveric knees as described by the moment versus angular rotation behavior under varus-valgus moments at 0 deg, 30 deg, and 90 deg of flexion. The angular rotation of the CCK knee in response to the physiological moments was limited to ≤1.5 deg. The primary stabilizing mechanism was the redistribution of the contact force on the bearing surfaces. Contact between the tibial post and the femoral box provided a secondary stabilizing mechanism after lift-off of a condyle had occurred. Collateral ligaments provide limited stability because little ligament elongation occurred under such small angular rotations. Compressive loads applied across the knee joint, such as would occur with the application of muscle forces, enhanced the ability of the bearing surfaces to provide resisting internal varus-valgus moment and, thus, reduced the exposure of the tibial post to the external varus-valgus loads. Our results suggest that the CCK stability can be refined by considering both the geometry of the bearing surfaces and the contacting geometry between the tibial post and femoral box.

  20. Effectiveness of the Saline Load Test in Diagnosis of Traumatic Elbow Arthrotomies

    DTIC Science & Technology

    2011-11-01

    load test for the knee, using 80 knees in patients undergoing elective knee arthroscopy . A fixed volume of 60 mL of saline was injected while observing... Arthroscopy . 1990;6:100–103. 10. Voit GA, Irvine G, Beals RK. Saline load test for penetration of periarticular lacerations. J Bone Joint Surg Br. 1996;78:732...318. 12. Plancher KD, Shariff KB. Basics of elbow arthroscopy : setup, portals, and technique. Tech Orthop. 2006;21:239–249. 13. Marvel JE, Marsh HO

  1. Knee joint contact mechanics during downhill gait and its relationship with varus/valgus motion and muscle strength in patients with knee osteoarthritis.

    PubMed

    Farrokhi, Shawn; Voycheck, Carrie A; Gustafson, Jonathan A; Fitzgerald, G Kelley; Tashman, Scott

    2016-01-01

    The objective of this exploratory study was to evaluate tibiofemoral joint contact point excursions and velocities during downhill gait and assess the relationship between tibiofemoral joint contact mechanics with frontal-plane knee joint motion and lower extremity muscle weakness in patients with knee osteoarthritis (OA). Dynamic stereo X-ray was used to quantify tibiofemoral joint contact mechanics and frontal-plane motion during the loading response phase of downhill gait in 11 patients with knee OA and 11 control volunteers. Quantitative testing of the quadriceps and the hip abductor muscles was also performed. Patients with knee OA demonstrated larger medial/lateral joint contact point excursions (p < 0.02) and greater heel-strike joint contact point velocities (p < 0.05) for the medial and lateral compartments compared to the control group. The peak medial/lateral joint contact point velocity of the medial compartment was also greater for patients with knee OA compared to their control counterparts (p = 0.02). Additionally, patients with knee OA demonstrated significantly increased frontal-plane varus motion excursions (p < 0.01) and greater quadriceps and hip abductor muscle weakness (p = 0.03). In general, increased joint contact point excursions and velocities in patients with knee OA were linearly associated with greater frontal-plane varus motion excursions (p < 0.04) but not with quadriceps or hip abductor strength. Altered contact mechanics in patients with knee OA may be related to compromised frontal-plane joint stability but not with deficits in muscle strength.

  2. Expressing the joint moments of drop jumps and sidestep cutting in different reference frames--does it matter?

    PubMed

    Kristianslund, Eirik; Krosshaug, Tron; Mok, Kam-Ming; McLean, Scott; van den Bogert, Antonie J

    2014-01-03

    Joint moments help us understand joint loading and muscle function during movement. However, the interpretation depends on the choice of reference frame, but the different reference frames have not been compared in dynamic, high-impact sporting movements. We have compared the magnitude and the resulting ranking of hip and knee joint moments expressed in the laboratory coordinate system, the local system of the distal segment and projected or decomposed to the Joint Coordinate System (JCS) axes. Hip and knee joint moments of drop jumps and sidestep cutting in 70 elite female handball players were calculated based on recordings from an eight-camera 240 Hz system and two force platforms and expressed with the four methods. The greatest variations in magnitude between conditions were seen for drop jump hip internal rotation (range: 0.31-0.71 Nm/kg) and sidestep cutting knee flexion (2.87-3.39 Nm/kg) and hip internal rotation (0.87-2.36 Nm/kg) and knee internal rotation (0.10-0.40 Nm/kg) moments. The rank correlations were highest between conditions for flexion moments (0.88-1.00) and sidestep cutting abduction moments (0.71-0.98). The rank correlations ranged from 0.64 to 0.73 for drop jump knee abduction moments and between -0.17 and 0.67 for hip and knee internal rotation moments. Expression of joint moments in different reference systems affects the magnitude and ranking of athletes. This lack of consistency may complicate the comparison and combination of results. Projection to the JCS is the only method where joint moments correspond to muscle and ligament loading. More widespread adoption of this convention could facilitate comparison of studies and ease the interpretation of results. © 2013 Elsevier Ltd. All rights reserved.

  3. Hip and knee joint loading during vertical jumping and push jerking

    PubMed Central

    Cleather, Daniel J; Goodwin, Jon E; Bull, Anthony MJ

    2014-01-01

    Background The internal joint contact forces experienced at the lower limb have been frequently studied in activities of daily living and rehabilitation activities. In contrast, the forces experienced during more dynamic activities are not well understood, and those studies that do exist suggest very high degrees of joint loading. Methods In this study a biomechanical model of the right lower limb was used to calculate the internal joint forces experienced by the lower limb during vertical jumping, landing and push jerking (an explosive exercise derived from the sport of Olympic weightlifting), with a particular emphasis on the forces experienced by the knee. Findings The knee experienced mean peak loadings of 2.4-4.6 × body weight at the patellofemoral joint, 6.9-9.0 × body weight at the tibiofemoral joint, 0.3-1.4 × body weight anterior tibial shear and 1.0-3.1 × body weight posterior tibial shear. The hip experienced a mean peak loading of 5.5-8.4 × body weight and the ankle 8.9-10.0 × body weight. Interpretation The magnitudes of the total (resultant) joint contact forces at the patellofemoral joint, tibiofemoral joint and hip are greater than those reported in activities of daily living and less dynamic rehabilitation exercises. The information in this study is of importance for medical professionals, coaches and biomedical researchers in improving the understanding of acute and chronic injuries, understanding the performance of prosthetic implants and materials, evaluating the appropriateness of jumping and weightlifting for patient populations and informing the training programmes of healthy populations. PMID:23146164

  4. Hip and knee joint loading during vertical jumping and push jerking.

    PubMed

    Cleather, Daniel J; Goodwin, Jon E; Bull, Anthony M J

    2013-01-01

    The internal joint contact forces experienced at the lower limb have been frequently studied in activities of daily living and rehabilitation activities. In contrast, the forces experienced during more dynamic activities are not well understood, and those studies that do exist suggest very high degrees of joint loading. In this study a biomechanical model of the right lower limb was used to calculate the internal joint forces experienced by the lower limb during vertical jumping, landing and push jerking (an explosive exercise derived from the sport of Olympic weightlifting), with a particular emphasis on the forces experienced by the knee. The knee experienced mean peak loadings of 2.4-4.6×body weight at the patellofemoral joint, 6.9-9.0×body weight at the tibiofemoral joint, 0.3-1.4×body weight anterior tibial shear and 1.0-3.1×body weight posterior tibial shear. The hip experienced a mean peak loading of 5.5-8.4×body weight and the ankle 8.9-10.0×body weight. The magnitudes of the total (resultant) joint contact forces at the patellofemoral joint, tibiofemoral joint and hip are greater than those reported in activities of daily living and less dynamic rehabilitation exercises. The information in this study is of importance for medical professionals, coaches and biomedical researchers in improving the understanding of acute and chronic injuries, understanding the performance of prosthetic implants and materials, evaluating the appropriateness of jumping and weightlifting for patient populations and informing the training programmes of healthy populations. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Effects of Step Rate Manipulation on Joint Mechanics during Running

    PubMed Central

    Heiderscheit, Bryan C.; Chumanov, Elizabeth S.; Michalski, Max P.; Wille, Christa M.; Ryan, Michael B.

    2010-01-01

    Purpose The objective of this study was to characterize the biomechanical effects of step rate modification during running on the hip, knee and ankle joints, so as to evaluate a potential strategy to reduce lower extremity loading and risk for injury. Methods Three-dimensional kinematics and kinetics were recorded from 45 healthy recreational runners during treadmill running at constant speed under various step rate conditions (preferred, ± 5% and ± 10%). We tested our primary hypothesis that a reduction in energy absorption by the lower extremity joints during the loading response would occur, primarily at the knee, when step rate was increased. Results Less mechanical energy was absorbed at the knee (p<0.01) during the +5% and +10% step rate conditions, while the hip (p<0.01) absorbed less energy during the +10% condition only. All joints displayed substantially (p<0.01) more energy absorption when preferred step rate was reduced by 10. Step length (p<0.01), center of mass vertical excursion (p<0.01), breaking impulse (p<0.01) and peak knee flexion angle (p<0.01) were observed to decrease with increasing step rate. When step rate was increased 10% above preferred, peak hip adduction angle (p<0.01), as well as peak hip adduction (p<0.01) and internal rotation (p<0.01) moments, were found to decrease. Conclusion We conclude that subtle increases in step rate can substantially reduce the loading to the hip and knee joints during running and may prove beneficial in the prevention and treatment of common running-related injuries. PMID:20581720

  6. Design, simulation and modelling of auxiliary exoskeleton to improve human gait cycle.

    PubMed

    Ashkani, O; Maleki, A; Jamshidi, N

    2017-03-01

    Exoskeleton is a walking assistance device that improves human gait cycle through providing auxiliary force and transferring physical load to the stronger muscles. This device takes the natural state of organ and follows its natural movement. Exoskeleton functions as an auxiliary device to help those with disabilities in hip and knee such as devotees, elderly farmers and agricultural machinery operators who suffer from knee complications. In this research, an exoskeleton designed with two screw jacks at knee and hip joints. To simulate extension and flexion movements of the leg joints, bearings were used at the end of hip and knee joints. The generated torque and motion angles of these joints obtained as well as the displacement curves of screw jacks in the gait cycle. Then, the human gait cycle was simulated in stance and swing phases and the obtained torque curves were compared. The results indicated that they followed the natural circle of the generated torque in joints with a little difference from each other. The maximum displacement obtained 4 and 6 cm in hip and knee joints jack respectively. The maximum torques in hip and knee joints were generated in foot contact phase. Also the minimum torques in hip and knee joints were generated in toe off and heel off phases respectively.

  7. Validation of predicted patellofemoral mechanics in a finite element model of the healthy and cruciate-deficient knee.

    PubMed

    Ali, Azhar A; Shalhoub, Sami S; Cyr, Adam J; Fitzpatrick, Clare K; Maletsky, Lorin P; Rullkoetter, Paul J; Shelburne, Kevin B

    2016-01-25

    Healthy patellofemoral (PF) joint mechanics are critical to optimal function of the knee joint. Patellar maltracking may lead to large joint reaction loads and high stresses on the articular cartilage, increasing the risk of cartilage wear and the onset of osteoarthritis. While the mechanical sources of PF joint dysfunction are not well understood, links have been established between PF tracking and abnormal kinematics of the tibiofemoral (TF) joint, specifically following cruciate ligament injury and repair. The objective of this study was to create a validated finite element (FE) representation of the PF joint in order to predict PF kinematics and quadriceps force across healthy and pathological specimens. Measurements from a series of dynamic in-vitro cadaveric experiments were used to develop finite element models of the knee for three specimens. Specimens were loaded under intact, ACL-resected and both ACL and PCL-resected conditions. Finite element models of each specimen were constructed and calibrated to the outputs of the intact knee condition, and subsequently used to predict PF kinematics, contact mechanics, quadriceps force, patellar tendon moment arm and patellar tendon angle of the cruciate resected conditions. Model results for the intact and cruciate resected trials successfully matched experimental kinematics (avg. RMSE 4.0°, 3.1mm) and peak quadriceps forces (avg. difference 5.6%). Cruciate resections demonstrated either increased patellar tendon loads or increased joint reaction forces. The current study advances the standard for evaluation of PF mechanics through direct validation of cruciate-resected conditions including specimen-specific representations of PF anatomy. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Ready to Use Tissue Construct for Military Bone & Cartilage Trauma

    DTIC Science & Technology

    2014-10-01

    during nail introduction and reaming. In the present study, we examined the load - bearing capacity and optimal internal fixation of a bone/poly-ε...segmental defect, (a) axial loading via ball bearing , (b) torsional loading via square clamp allowing axial displacement, (c) three-point bending of tibia...knee joints by simulating loads seen during ambulation and knee range of motion. Our central hypothesis is that an anatomically and

  9. The biomechanical effect of increased valgus on total knee arthroplasty: a cadaveric study.

    PubMed

    Bryant, Brandon J; Tilan, Justin U; McGarry, Michelle H; Takenaka, Nobuyuki; Kim, William C; Lee, Thay Q

    2014-04-01

    The effects of valgus load on cadaveric knees following total knee arthroplasty (TKA) were investigated using a custom testing system. TKAs were performed on 8 cadaveric knees and tested at 0°, 30°, and 60° knee flexion in both neutral and 5° valgus. Fuji pressure sensitive film was used to quantify contact areas and pressures and MCL strain was determined using a Microscribe digitizing system. Lateral tibiofemoral pressures increased (P < 0.05) at all knee flexion angles with valgus loading. Patellofemoral contact characteristics did not change significantly (P > 0.05). Significant increases in strain were observed along the anterior and posterior border of the MCL at all knee flexion angles. These findings suggest that valgus loading increases TKA joint contact pressures and MCL strain with increasing knee flexion which may increase implant instability. © 2014.

  10. The Meniscus-Deficient Knee

    PubMed Central

    Rao, Allison J.; Erickson, Brandon J.; Cvetanovich, Gregory L.; Yanke, Adam B.; Bach, Bernard R.; Cole, Brian J.

    2015-01-01

    Meniscal tears are the most common knee injury, and partial meniscectomies are the most common orthopaedic surgical procedure. The injured meniscus has an impaired ability to distribute load and resist tibial translation. Partial or complete loss of the meniscus promotes early development of chondromalacia and osteoarthritis. The primary goal of treatment for meniscus-deficient knees is to provide symptomatic relief, ideally to delay advanced joint space narrowing, and ultimately, joint replacement. Surgical treatments, including meniscal allograft transplantation (MAT), high tibial osteotomy (HTO), and distal femoral osteotomy (DFO), are options that attempt to decrease the loads on the articular cartilage of the meniscus-deficient compartment by replacing meniscal tissue or altering joint alignment. Clinical and biomechanical studies have reported promising outcomes for MAT, HTO, and DFO in the postmeniscectomized knee. These procedures can be performed alone or in conjunction with ligament reconstruction or chondral procedures (reparative, restorative, or reconstructive) to optimize stability and longevity of the knee. Complications can include fracture, nonunion, patella baja, compartment syndrome, infection, and deep venous thrombosis. MAT, HTO, and DFO are effective options for young patients suffering from pain and functional limitations secondary to meniscal deficiency. PMID:26779547

  11. Image based weighted center of proximity versus directly measured knee contact location during simulated gait

    PubMed Central

    Wang, Hongsheng; Chen, Tony; Koff, Matthew F.; Hutchinson, Ian D.; Gilbert, Susannah; Choi, Dan; Warren, Russell F.; Rodeo, Scott A.; Maher, Suzanne A.

    2014-01-01

    To understand the mechanical consequences of knee injury requires a detailed analysis of the effect of that injury on joint contact mechanics during activities of daily living. Three-dimensional (3D) knee joint geometric models have been combined with knee joint kinematics to dynamically estimate the location of joint contact during physiological activities – using a weighted center of proximity (WCoP) method. However, the relationship between the estimated WCoP and the actual location of contact has not been defined. The objective of this study was to assess the relationship between knee joint contact location as estimated using the image-based WCoP method, and a directly measured weighted center of contact (WCoC) method during simulated walking. To achieve this goal, we created knee specific models of six human cadaveric knees from magnetic resonance imaging. All knees were then subjected to physiological loads on a knee simulator intended to mimic gait. Knee joint motion was captured using a motion capture system. Knee joint contact stresses were synchronously recorded using a thin electronic sensor throughout gait, and used to compute WCoC for the medial and lateral plateaus of each knee. WCoP was calculated by combining knee kinematics with the MRI-based knee specific model. Both metrics were compared throughout gait using linear regression. The anteroposterior (AP) location of WCoP was significantly correlated with that of WCoC on both tibial plateaus in all specimens (P < 0.01, 95% confidence interval of Person’s coefficient r > 0), but the correlation was not significant in the mediolateral (ML) direction for 4/6 knees (P > 0.05). Our study demonstrates that while the location of joint contact obtained from 3D knee joint contact model, using the WCoP method, is significantly correlated with the location of actual contact stresses in the AP direction, that relationship is less certain in the ML direction. PMID:24837219

  12. Stair ascent with an innovative microprocessor-controlled exoprosthetic knee joint.

    PubMed

    Bellmann, Malte; Schmalz, Thomas; Ludwigs, Eva; Blumentritt, Siegmar

    2012-12-01

    Climbing stairs can pose a major challenge for above-knee amputees as a result of compromised motor performance and limitations to prosthetic design. A new, innovative microprocessor-controlled prosthetic knee joint, the Genium, incorporates a function that allows an above-knee amputee to climb stairs step over step. To execute this function, a number of different sensors and complex switching algorithms were integrated into the prosthetic knee joint. The function is intuitive for the user. A biomechanical study was conducted to assess objective gait measurements and calculate joint kinematics and kinetics as subjects ascended stairs. Results demonstrated that climbing stairs step over step is more biomechanically efficient for an amputee using the Genium prosthetic knee than the previously possible conventional method where the extended prosthesis is trailed as the amputee executes one or two steps at a time. There is a natural amount of stress on the residual musculoskeletal system, and it has been shown that the healthy contralateral side supports the movements of the amputated side. The mechanical power that the healthy contralateral knee joint needs to generate during the extension phase is also reduced. Similarly, there is near normal loading of the hip joint on the amputated side.

  13. Muscle activity during leg strengthening exercise using free weights and elastic resistance: effects of ballistic vs controlled contractions.

    PubMed

    Jakobsen, Markus Due; Sundstrup, Emil; Andersen, Christoffer H; Aagaard, Per; Andersen, Lars L

    2013-02-01

    The present study's aim was to evaluate muscle activity during leg exercises using elastic vs. isoinertial resistance at different exertion and loading levels, respectively. Twenty-four women and eighteen men aged 26-67 years volunteered to participate in the experiment. Electromyographic (EMG) activity was recorded in nine muscles during a standardized forward lunge movement performed with dumbbells and elastic bands during (1) ballistic vs. controlled exertion, and (2) at low, medium and high loads (33%, 66% and 100% of 10 RM, respectively). The recorded EMG signals were normalized to MVC EMG. Knee joint angle was measured using electronic inclinometers. The following results were obtained. Loading intensity affected EMG amplitude in the order: low

  14. Cyclic loading increases friction and changes cartilage surface integrity in lubricin-mutant mouse knees

    PubMed Central

    Drewniak, Elizabeth I; Jay, Gregory D; Fleming, Braden C; Zhang, Ling; Warman, Matthew L; Crisco, Joseph J

    2012-01-01

    Objective To investigate the effects of lubricin gene dosage and cyclic loading on whole joint coefficient of friction and articular cartilage surface integrity in mouse knee joints. Methods Joints from mice with 2 (Prg4+/+), 1 (Prg4+/−), or no (Prg4−/−) functioning lubricin alleles were subjected to 26 hours of cyclic loading using a custom-built pendulum. Coefficient of friction values were measured at multiple time points. Contralateral control joints were left unloaded. Following testing, joints were examined for histologic evidence of damage and cell viability. Results At baseline, the coefficient of friction values in Prg4−/− mice were significantly higher than those in Prg4+/+ and Prg4+/− mice (P < 0.001). Cyclic loading continuously increased the coefficient of friction in Prg4−/− mouse joints. In contrast, Prg4+/− and Prg4+/+ mouse joints had no coefficient of friction increases during the first 4 hours of loading. After 26 hours of loading, joints from all genotypes had increased coefficient of friction values compared to baseline and unloaded controls. Significantly greater increases occurred in Prg4−/− and Prg4+/− mouse joints compared to Prg4+/+ mouse joints. The coefficient of friction values were not significantly associated with histologic evidence of damage or loss of cell viability. Conclusion Our findings indicate that mice lacking lubricin have increased baseline coefficient of friction values and are not protected against further increases caused by loading. Prg4+/− mice are indistinguishable from Prg4+/+ mice at baseline, but have significantly greater coefficient of friction values following 26 hours of loading. Lubricin dosage affects joint properties during loading, and may have clinical implications in patients for whom injury or illness alters lubricin abundance. PMID:21905020

  15. The effects of load carriage and muscle fatigue on lower-extremity joint mechanics.

    PubMed

    Wang, He; Frame, Jeff; Ozimek, Elicia; Leib, Daniel; Dugan, Eric L

    2013-09-01

    Military personnel are commonly afflicted by lower-extremity overuse injuries. Load carriage and muscular fatigue are major stressors during military basic training. To examine effects of load carriage and muscular fatigue on lower-extremity joint mechanics during walking. Eighteen men performed the following tasks: unloaded walking, walking with a 32-kg load, fatigued walking with a 32-kg load, and fatigued walking. After the second walking task, muscle fatigue was elicited through a fatiguing protocol consisting of metered step-ups and heel raises with a 16-kg load. Each walking task was performed at 1.67 m x s(-1) for 5 min. Walking movement was tracked by a VICON motion capture system at 120 Hz. Ground reaction forces were collected by a tandem force instrumented treadmill (AMTI) at 2,400 Hz. Lower-extremity joint mechanics were calculated in Visual 3D. There was no interaction between load carriage and fatigue on lower-extremity joint mechanics (p > .05). Both load carriage and fatigue led to pronounced alterations of lower-extremity joint mechanics (p < .05). Load carriage resulted in increases of pelvis anterior tilt, hip and knee flexion at heel contact, and increases of hip, knee, and ankle joint moments and powers during weight acceptance. Muscle fatigue led to decreases of ankle dorsiflexion at heel contact, dorsiflexor moment, and joint power at weight acceptance. In addition, muscle fatigue increased demand for hip extensor moment and power at weight acceptance. Statistically significant changes in lower-extremity joint mechanics during loaded and fatigued walking may expose military personnel to increased risk for overuse injuries.

  16. Female Adults with Patellofemoral Pain Are Characterized by Widespread Hyperalgesia, Which Is Not Affected Immediately by Patellofemoral Joint Loading.

    PubMed

    Pazzinatto, Marcella Ferraz; de Oliveira Silva, Danilo; Barton, Christian; Rathleff, Michael Skovdal; Briani, Ronaldo Valdir; de Azevedo, Fábio Mícolis

    2016-10-01

    Compare pressure pain thresholds (PPTs) at the knee and a site remote to the knee in female adults with patellofemoral pain (PFP) to pain-free controls before and after a patellofemoral joint (PFJ) loading protocol designed to aggravate symptoms. Cross-sectional study SETTING: Participants were recruited via advertisements in fitness centers, public places for physical activity and universities. Thirty-eight females with patellofemoral pain, and 33 female pain-free controls. All participant performed a novel PFJ loading protocol involving stair negotiation with an extra load equivalent 35% of body mass. PPTs and current knee pain (measured on a visual analogue scale) was assessed before and after the loading protocol. PPTs were measured at four sites around the knee and one remote site on the upper contralateral limb. Females with PFP demonstrated significantly lower PPTs locally and remote to the knee, both before and after the PFJ loading protocol when compared to control group. Following the loading protocol, PPTs at knee were significantly reduced by 0.54 kgf (95%CI = 0.33; 0.74) for quadriceps tendon, 0.38 kgf (95%CI = 0.14; 0.63) for medial patella, and 0.44 kgf (95%CI = 0.18; 0.69) for lateral patella. No significant change in PPT remote to the knee was observed - 0.10 kgf (95%CI = -0.04; 0.24). Female adults with PFP have local and widespread hyperalgesia compared to pain free controls. A novel loading protocol designed to aggravate symptoms, lowers the PPTs locally at the knee but has no effect on PPT on the upper contralateral limb. This suggests widespread hyperalgesia is not affected by acute symptom aggravation. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  17. Knee contact forces are not altered in early knee osteoarthritis.

    PubMed

    Meireles, S; De Groote, F; Reeves, N D; Verschueren, S; Maganaris, C; Luyten, F; Jonkers, I

    2016-03-01

    This study calculated knee contact forces (KCF) and its relations with knee external knee adduction moments (KAM) and/or flexion moments (KFM) during the stance phase of gait in patients with early osteoarthritis (OA), classified based on early joint degeneration on Magnetic Resonance Imaging (MRI). We aimed at assessing if altered KCF are already present in early structural degeneration. Three-dimensional motion and ground reaction force data in 59 subjects with medial compartment knee OA (N=23 established OA, N=16 early OA, N=20 controls) were used as input for a musculoskeletal model. KAM and KFM, and KCF were estimated using OpenSim software. No significant differences were found between controls and subjects with early OA. In early OA patients, KAM significantly explained 69% of the variance associated with the first peaks KCF but only KFM contributed to the second peaks KCF. The multiple correlation, combining KAM and KFM, showed to be higher. However, only 20% of the variance of second peak KCF was explained by both moments in established OA. KCF are not increased in patients with early OA, suggesting that knee joint overload is more a consequence of further joint degeneration in more advanced stages of OA. Additionally, our results clearly show that KAM is not sufficient to predict joint loading at the end of the stance, where KFM contributes substantially to the loading, especially in early OA. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Variations in medial-lateral hamstring force and force ratio influence tibiofemoral kinematics.

    PubMed

    Shalhoub, Sami; Fitzwater, Fallon G; Cyr, Adam J; Maletsky, Lorin P

    2016-10-01

    A change in hamstring strength and activation is typically seen after injuries or invasive surgeries such as anterior cruciate reconstruction or total knee replacement. While many studies have investigated the influence of isometric increases in hamstring load on knee joint kinematics, few have quantified the change in kinematics due to a variation in medial to lateral hamstring force ratio. This study examined the changes in knee joint kinematics on eight cadaveric knees during an open-chain deep knee bend for six different loading configurations: five loaded hamstring configurations that varied the ratio of a total load of 175 N between the semimembranosus and biceps femoris and one with no loads on the hamstring. The anterior-posterior translation of the medial and lateral femoral condyles' lowest points along proximal-distal axis of the tibia, the axial rotation of the tibia, and the quadriceps load were measured at each flexion angle. Unloading the hamstring shifted the medial and lateral lowest points posteriorly and increased tibial internal rotation. The influence of unloading hamstrings on quadriceps load was small in early flexion and increased with knee flexion. The loading configuration with the highest lateral hamstrings force resulted in the most posterior translation of the medial lowest point, most anterior translation of the lateral lowest point, and the highest tibial external rotation of the five loading configurations. As the medial hamstring force ratio increased, the medial lowest point shifted anteriorly, the lateral lowest point shifted posteriorly, and the tibia rotated more internally. The results of this study, demonstrate that variation in medial-lateral hamstrings force and force ratio influence tibiofemoral transverse kinematics and quadriceps loads required to extend the knee. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1707-1715, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  19. Knee degeneration in concrete reinforcement workers.

    PubMed Central

    Wickström, G; Hänninen, K; Mattsson, T; Niskanen, T; Riihimäki, H; Waris, P; Zitting, A

    1983-01-01

    The loads on the knees in concrete reinforcement work and maintenance painting were analysed on eight construction work sites. A total of 352 reinforcement workers and 231 painters. Finnish men aged 20-64, were clinically and radiologically examined to determine the condition of the knee joints in active workers. The loads on the knees and the occurrence of minor injuries and accidents were higher in reinforcement work than in painting, but the occurrence of symptoms, clinical signs, and radiological findings was equally common in both groups. Reinforcement work seemed to provoke more symptoms from degenerated knees than painting. PMID:6830721

  20. Body mass index affects knee joint mechanics during gait differently with and without moderate knee osteoarthritis.

    PubMed

    Harding, Graeme T; Hubley-Kozey, Cheryl L; Dunbar, Michael J; Stanish, William D; Astephen Wilson, Janie L

    2012-11-01

    Obesity is a highly cited risk factor for knee osteoarthritis (OA), but its role in knee OA pathogenesis and progression is not as clear. Excess weight may contribute to an increased mechanical burden and altered dynamic movement and loading patterns at the knee. The objective of this study was to examine the interacting role of moderate knee OA disease presence and obesity on knee joint mechanics during gait. Gait analysis was performed on 104 asymptomatic and 140 individuals with moderate knee OA. Each subject group was divided into three body mass categories based on body mass index (BMI): healthy weight (BMI<25), overweight (25≤BMI≤30), and obese (BMI>30). Three-dimensional knee joint angles and net external knee joint moments were calculated and waveform principal component analysis (PCA) was applied to extract major patterns of variability from each. PC scores for major patterns were compared between groups using a two-factor ANOVA. Significant BMI main effects were found in the pattern of the knee adduction moment, the knee flexion moment, and the knee rotation moment during gait. Two interaction effects between moderate OA disease presence and BMI were also found that described different changes in the knee flexion moment and the knee flexion angle with increased BMI with and without knee OA. Our results suggest that increased BMI is associated with different changes in biomechanical patterns of the knee joint during gait depending on the presence of moderate knee OA. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  1. The differential effects of gender, anthropometry, and prior hormonal state on frontal plane knee joint stiffness

    PubMed Central

    Cammarata, Martha L.; Dhaher, Yasin Y.

    2012-01-01

    Background Gender differences in passive frontal plane knee stiffness may contribute to the increased anterior cruciate ligament injury rate in females. Gender-based stiffness differences have been attributed to anthropometric variations, but little data exist describing this relationship. Furthermore, sex hormone levels appear to influence joint stiffness, but the differential effects of instantaneous and prior hormonal concentrations remain unknown. This study sought to explore the effect of gender, prior hormonal status, and anthropometry on passive frontal plane knee joint stiffness. Methods Twelve males and 31 females participated. Females were grouped by hormonal contraceptive use (non users [n=11], monophasic contraceptive users [n=11], and triphasic contraceptive users [n=9]) and tested at the same point in the menstrual cycle. Subjects’ right knee was passively stretched ±7° in the frontal plane at 3°/s. Stiffness was estimated at three loading levels and normalized by body size to minimize anthropometric biases. A 4 (group) × 3 (load) repeated measures analysis of variance was performed for both raw and normalized stiffness. Linear regression analyses were preformed between stiffness estimates and knee diameter and quadriceps femoris angle. Findings Males displayed significantly greater (P<0.05) frontal plane stiffness than females. When normalized, males displayed significantly greater stiffness in valgus (P<0.05), but not varus (P>0.05) than females. No significant effect (P>0.05) of prior hormonal state was found; however, when normalized, varus stiffness was significantly less for triphasic contraceptive users than the other female groups (P<0.05). Quadriceps femoris angle was negatively correlated and knee diameter was positively correlated to knee stiffness. Interpretation Consistent with earlier in vitro findings, our data may indicate that ligament material properties are gender specific. A deficit in passive knee joint stiffness may place a larger burden on the neuromuscular system to resist frontal plane loading in females. PMID:18479791

  2. The effect of low-load exercise on joint pain, function, and activities of daily living in patients with knee osteoarthritis.

    PubMed

    Peeler, Jason; Ripat, Jacquie

    2018-01-01

    Knee osteoarthritis has a lifetime risk of nearly one in two, with obese individuals being most susceptible. While exercise is universally recognized as a critical component for management, unsafe or ineffective exercise frequently leads to exacerbation of joint symptoms. Evaluate the effect of a 12week lower body positive pressure (LBPP) supported low-load treadmill walking program on knee pain, joint function, and performance of daily activities in patients with knee osteoarthritis (OA). Prospective, observational, repeated measures investigation. Community based, multidisciplinary musculoskeletal medicine clinic. Thirty-one patients, aged 50-75, with a BMI ≥25kg/m 2 and radiographic confirmed mild to moderate knee OA. Twelve week LBPP treadmill walking exercise regimen. The Knee Injury and Osteoarthritis Outcome Score (KOOS) and the Canadian Occupational Performance Measure (COPM) were used to quantify joint symptoms and patient function; isokinetic thigh muscle strength was evaluated; and a 10-point VAS was used to quantify acute knee pain while walking. Baseline and follow-up data were compared in order to examine the effect of the 12week exercise intervention. There was a significant difference between baseline and follow-up data: KOOS and COPM scores both improved; thigh muscle strength increased; and acute knee pain during full weight bearing walking diminished significantly. Participation in a 12week LBPP supported treadmill walking exercise regimen significantly enhanced patient function and quality of life, as well as the ability to perform activities of daily living that patient's self-identified as being important, yet difficult to perform. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. The Relationship Between Early-Stage Knee Osteoarthritis and Lower-Extremity Alignment, Joint Laxity, and Subjective Scores of Pain, Stiffness, and Function.

    PubMed

    Hicks-Little, Charlie A; Peindl, Richard D; Hubbard-Turner, Tricia J; Cordova, Mitchell L

    2016-08-01

    Knee osteoarthritis (OA) is a debilitating disease that affects an estimated 27 million Americans. Changes in lower-extremity alignment and joint laxity have been found to redistribute the medial and/or lateral loads at the joint. However, the effect that changes in anteroposterior knee-joint laxity have on lower-extremity alignment and function in individuals with knee OA remains unclear. To examine anteroposterior knee-joint laxity, lower-extremity alignment, and subjective pain, stiffness, and function scores in individuals with early-stage knee OA and matched controls and to determine if a relationship exists among these measures. Case control. Sports-medicine research laboratory. 18 participants with knee OA and 18 healthy matched controls. Participants completed the Western Ontario McMaster (WOMAC) osteoarthritis questionnaire and were tested for total anteroposterior knee-joint laxity (A-P) and knee-joint alignment (ALIGN). WOMAC scores, A-P (mm), and ALIGN (°). A significant multivariate main effect for group (Wilks' Λ = 0.30, F7,26 = 8.58, P < .0001) was found. Knee-OA participants differed in WOMAC scores (P < .0001) but did not differ from healthy controls on ALIGN (P = .49) or total A-P (P = .66). No significant relationships were identified among main outcome measures. These data demonstrate that participants with early-stage knee OA had worse pain, stiffness, and functional outcome scores than the matched controls; however, ALIGN and A-P were no different. There was no association identified among participants' subjective scores, ALIGN, or A-P measures in this study.

  4. Reduced step length reduces knee joint contact forces during running following anterior cruciate ligament reconstruction but does not alter inter-limb asymmetry.

    PubMed

    Bowersock, Collin D; Willy, Richard W; DeVita, Paul; Willson, John D

    2017-03-01

    Anterior cruciate ligament reconstruction is associated with early onset knee osteoarthritis. Running is a typical activity following this surgery, but elevated knee joint contact forces are thought to contribute to osteoarthritis degenerative processes. It is therefore clinically relevant to identify interventions to reduce contact forces during running among individuals after anterior cruciate ligament reconstruction. The primary purpose of this study was to evaluate the effect of reducing step length during running on patellofemoral and tibiofemoral joint contact forces among people with a history of anterior cruciate ligament reconstruction. Inter limb knee joint contact force differences during running were also examined. 18 individuals at an average of 54.8months after unilateral anterior cruciate ligament reconstruction ran in 3 step length conditions (preferred, -5%, -10%). Bilateral patellofemoral, tibiofemoral, and medial tibiofemoral compartment peak force, loading rate, impulse, and impulse per kilometer were evaluated between step length conditions and limbs using separate 2 factor analyses of variance. Reducing step length 5% decreased patellofemoral, tibiofemoral, and medial tibiofemoral compartment peak force, impulse, and impulse per kilometer bilaterally. A 10% step length reduction further decreased peak forces and force impulses, but did not further reduce force impulses per kilometer. Tibiofemoral joint impulse, impulse per kilometer, and patellofemoral joint loading rate were lower in the previously injured limb compared to the contralateral limb. Running with a shorter step length is a feasible clinical intervention to reduce knee joint contact forces during running among people with a history of anterior cruciate ligament reconstruction. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Pressure mapping at orthopaedic joint interfaces with fiber Bragg gratings

    NASA Astrophysics Data System (ADS)

    Mohanty, Lipi; Tjin, Swee Chuan

    2006-02-01

    We present the concept of a fiber-optic sensor that can be used for pressure mapping at the prosthetic knee joint, in vitro and in vivo. An embedded array of fiber Bragg gratings is used to measure the load on the tibial spacer. The sensor gives the magnitude and the location of the applied load. The effect of material properties on the sensitivity of each subgrating is presented. The wavelength-shift maps show the malalignment of implants and demonstrate the potential of this sensor for use during total knee arthroplasty.

  6. Measuring the effect of femoral malrotation on knee joint biomechanics for total knee arthroplasty using computational simulation

    PubMed Central

    Kang, K-T.; Koh, Y-G.; Son, J.; Kwon, O-R.; Baek, C.; Jung, S. H.

    2016-01-01

    Objectives Malrotation of the femoral component can result in post-operative complications in total knee arthroplasty (TKA), including patellar maltracking. Therefore, we used computational simulation to investigate the influence of femoral malrotation on contact stresses on the polyethylene (PE) insert and on the patellar button as well as on the forces on the collateral ligaments. Materials and Methods Validated finite element (FE) models, for internal and external malrotations from 0° to 10° with regard to the neutral position, were developed to evaluate the effect of malrotation on the femoral component in TKA. Femoral malrotation in TKA on the knee joint was simulated in walking stance-phase gait and squat loading conditions. Results Contact stress on the medial side of the PE insert increased with internal femoral malrotation and decreased with external femoral malrotation in both stance-phase gait and squat loading conditions. There was an opposite trend in the lateral side of the PE insert case. Contact stress on the patellar button increased with internal femoral malrotation and decreased with external femoral malrotation in both stance-phase gait and squat loading conditions. In particular, contact stress on the patellar button increased by 98% with internal malrotation of 10° in the squat loading condition. The force on the medial collateral ligament (MCL) and the lateral collateral ligament (LCL) increased with internal and external femoral malrotations, respectively. Conclusions These findings provide support for orthopaedic surgeons to determine a more accurate femoral component alignment in order to reduce post-operative PE problems. Cite this article: K-T. Kang, Y-G. Koh, J. Son, O-R. Kwon, C. Baek, S. H. Jung, K. K. Park. Measuring the effect of femoral malrotation on knee joint biomechanics for total knee arthroplasty using computational simulation. Bone Joint Res 2016;5:552–559. DOI: 10.1302/2046-3758.511.BJR-2016-0107.R1. PMID:28094763

  7. Knee loading inhibits osteoclast lineage in a mouse model of osteoarthritis

    PubMed Central

    Li, Xinle; Yang, Jing; Liu, Daquan; Li, Jie; Niu, Kaijun; Feng, Shiqing; Yokota, Hiroki; Zhang, Ping

    2016-01-01

    Osteoarthritis (OA) is a whole joint disorder that involves cartilage degradation and periarticular bone response. Changes of cartilage and subchondral bone are associated with development and activity of osteoclasts from subchondral bone. Knee loading promotes bone formation, but its effects on OA have not been well investigated. Here, we hypothesized that knee loading regulates subchondral bone remodeling by suppressing osteoclast development, and prevents degradation of cartilage through crosstalk of bone-cartilage in osteoarthritic mice. Surgery-induced mouse model of OA was used. Two weeks application of daily dynamic knee loading significantly reduced OARSI scores and CC/TAC (calcified cartilage to total articular cartilage), but increased SBP (subchondral bone plate) and B.Ar/T.Ar (trabecular bone area to total tissue area). Bone resorption of osteoclasts from subchondral bone and the differentiation of osteoclasts from bone marrow-derived cells were completely suppressed by knee loading. The osteoclast activity was positively correlated with OARSI scores and negatively correlated with SBP and B.Ar/T.Ar. Furthermore, knee loading exerted protective effects by suppressing osteoclastogenesis through Wnt signaling. Overall, osteoclast lineage is the hyper responsiveness of knee loading in osteoarthritic mice. Mechanical stimulation prevents OA-induced cartilage degeneration through crosstalk with subchondral bone. Knee loading might be a new potential therapy for osteoarthritis patients. PMID:27087498

  8. DINAMICS OF KNEE JOINT SPACE ASYMMETRY ON X-RAY AS A MARKER OF KNEE OSTEOARTHRITIS REHABILITATION EFFICACY.

    PubMed

    Sheveleva, N; Minbayeva, L; Belyayeva, Y

    2017-03-01

    Reducing of articular cartilage functional volume in knee joint osteoarthritis occurs unevenly and accompanied with pathological changes of lower limb axis as a result of connective tissue and muscle structures dysfunction. Evaluation of X-ray knee joint space asymmetry seems to be informative to analyze the dynamics of lower extremities biomechanical imbalances characteristic for knee joint osteoarthritis. However, standardized method of X-ray joint space determining does not include its symmetry calculation. The purpose of the study was optimization of knee joint radiological examination by developing of X-ray knee joint space asymmetry index calculation method. The proposed method was used for comparative analysis of extracorporeal shock-wave therapy efficacy in 30 patients with knee joint osteoarthritis of 2-3 degrees (Kellgren-Lawrence, 1957). As a result of the conducted treatment statistically significant decrease of the X-ray knee joint space asymmetry index was observed (Me(Q1;Q3): Z=5.20, p<0.001) and amounted as 0.22 (0.18;0.24) before treatment and 0.12 (0.10;0.14) after. Also, statistically significant (Z=5.10; p=0.00001) changes of load asymmetry on front and rear foot sections were observed by the results of podometric survey in comparative assessment before (Me(Q1;Q3)=24(12;30)) and after (Me(Q1;Q3)=6(4;30)) course therapy. 30% (n=9) of the patients evaluated the outcome of the treatment as "excellent" (1 point), 63% (n=19) - as "good" (2 points) and only 7% (n=2) - as "acceptable" (3 points) according to the Roles and Maudsley score. The listed above data was regarded as an X-ray positive dynamics comparable with clinical improvement. Thus, the X-ray knee joint space asymmetry index, calculated according to the proposed method, allows to evaluate dynamics of articular surfaces congruency changes and provide differentiated approach to the treatment of knee joint osteoarthritis.

  9. Combined magnetic resonance imaging approach for the assessment of in vivo knee joint kinematics under full weight-bearing conditions.

    PubMed

    Al Hares, Ghaith; Eschweiler, Jörg; Radermacher, Klaus

    2015-06-01

    The development of detailed and specific knowledge on the biomechanical behavior of loaded knee structures has received increased attention in recent years. Stress magnetic resonance imaging techniques have been introduced in previous work to study knee kinematics under load conditions. Previous studies captured the knee movement either in atypical loading supine positions, or in upright positions with help of inclined supporting backrests being insufficient for movement capture under full-body weight-bearing conditions. In this work, we used a combined magnetic resonance imaging approach for measurement and assessment in knee kinematics under full-body weight-bearing in single legged stance. The proposed method is based on registration of high-resolution static magnetic resonance imaging data acquired in supine position with low-resolution data, quasi-static upright-magnetic resonance imaging data acquired in loaded positions for different degrees of knee flexion. The proposed method was applied for the measurement of tibiofemoral kinematics in 10 healthy volunteers. The combined magnetic resonance imaging approach allows the non-invasive measurement of knee kinematics in single legged stance and under physiological loading conditions. We believe that this method can provide enhanced understanding of the loaded knee kinematics. © IMechE 2015.

  10. The effects of load carriage on joint work at different running velocities.

    PubMed

    Liew, Bernard X W; Morris, Susan; Netto, Kevin

    2016-10-03

    Running with load carriage has become increasingly prevalent in sport, as well as many field-based occupations. However, the "sources" of mechanical work during load carriage running are not yet completely understood. The purpose of this study was to determine the influence of load magnitudes on the mechanical joint work during running, across different velocities. Thirty-one participants performed overground running at three load magnitudes (0%, 10%, 20% body weight), and at three velocities (3, 4, 5m/s). Three dimensional motion capture was performed, with synchronised force plate data captured. Inverse dynamics was used to quantify joint work in the stance phase of running. Joint work was normalized to a unit proportion of body weight and leg length (one dimensionless work unit=532.45J). Load significantly increased total joint work and total positive work and this effect was greater at faster velocities. Load carriage increased ankle positive work (β coefficient=rate of 6.95×10 -4 unit work per 1% BW carried), and knee positive (β=1.12×10 -3 unit) and negative work (β=-2.47×10 -4 unit), and hip negative work (β=-7.79×10 -4 unit). Load carriage reduced hip positive work and this effect was smaller at faster velocities. Inter-joint redistribution did not contribute significantly to altered mechanical work within the spectrum of load and velocity investigated. Hence, the ankle joint contributed to the greatest extent in work production, whilst that of the knee contributed to the greatest extent to work absorption when running with load. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Are external knee load and EMG measures accurate indicators of internal knee contact forces during gait?

    PubMed

    Meyer, Andrew J; D'Lima, Darryl D; Besier, Thor F; Lloyd, David G; Colwell, Clifford W; Fregly, Benjamin J

    2013-06-01

    Mechanical loading is believed to be a critical factor in the development and treatment of knee osteoarthritis. However, the contact forces to which the knee articular surfaces are subjected during daily activities cannot be measured clinically. Thus, the ability to predict internal knee contact forces accurately using external measures (i.e., external knee loads and muscle electromyographic [EMG] signals) would be clinically valuable. We quantified how well external knee load and EMG measures predict internal knee contact forces during gait. A single subject with a force-measuring tibial prosthesis and post-operative valgus alignment performed four gait patterns (normal, medial thrust, walking pole, and trunk sway) to induce a wide range of external and internal knee joint loads. Linear regression analyses were performed to assess how much of the variability in internal contact forces was accounted for by variability in the external measures. Though the different gait patterns successfully induced significant changes in the external and internal quantities, changes in external measures were generally weak indicators of changes in total, medial, and lateral contact force. Our results suggest that when total contact force may be changing, caution should be exercised when inferring changes in knee contact forces based on observed changes in external knee load and EMG measures. Advances in musculoskeletal modeling methods may be needed for accurate estimation of in vivo knee contact forces. Copyright © 2012 Orthopaedic Research Society.

  12. Influence of weak hip abductor muscles on joint contact forces during normal walking: probabilistic modeling analysis.

    PubMed

    Valente, Giordano; Taddei, Fulvia; Jonkers, Ilse

    2013-09-03

    The weakness of hip abductor muscles is related to lower-limb joint osteoarthritis, and joint overloading may increase the risk for disease progression. The relationship between muscle strength, structural joint deterioration and joint loading makes the latter an important parameter in the study of onset and follow-up of the disease. Since the relationship between hip abductor weakness and joint loading still remains an open question, the purpose of this study was to adopt a probabilistic modeling approach to give insights into how the weakness of hip abductor muscles, in the extent to which normal gait could be unaltered, affects ipsilateral joint contact forces. A generic musculoskeletal model was scaled to each healthy subject included in the study, and the maximum force-generating capacity of each hip abductor muscle in the model was perturbed to evaluate how all physiologically possible configurations of hip abductor weakness affected the joint contact forces during walking. In general, the muscular system was able to compensate for abductor weakness. The reduced force-generating capacity of the abductor muscles affected joint contact forces to a mild extent, with 50th percentile mean differences up to 0.5 BW (maximum 1.7 BW). There were greater increases in the peak knee joint loads than in loads at the hip or ankle. Gluteus medius, particularly the anterior compartment, was the abductor muscle with the most influence on hip and knee loads. Further studies should assess if these increases in joint loading may affect initiation and progression of osteoarthritis. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Contact forces in the tibiofemoral joint from soft tissue tensions: Implications to soft tissue balancing in total knee arthroplasty.

    PubMed

    Verstraete, Matthias A; Meere, Patrick A; Salvadore, Gaia; Victor, Jan; Walker, Peter S

    2017-06-14

    Proper tension of the knee's soft tissue envelope is important during total knee arthroplasty; incorrect tensioning potentially leads to joint stiffness or instability. The latter remains an important trigger for revision surgery. The use of sensors quantifying the intra-articular loads, allows surgeons to assess the ligament tension at the time of surgery. However, realistic target values are missing. In the framework of this paper, eight non-arthritic cadaveric specimens were tested and the intra-articular loads transferred by the medial and lateral compartment were measured using custom sensor modules. These modules were inserted below the articulating surfaces of the proximal tibia, with the specimens mounted on a test setup that mimics surgical conditions. For both compartments, the highest loads are observed in full extension. While creating knee flexion by lifting the femur and flexing the hip, mean values (standard deviation) of 114N (71N) and 63N (28N) are observed at 0° flexion for the medial and lateral compartment respectively. Upon flexion, both medial and lateral loads decrease with mean values at 90° flexion of 30N (22N) and 6N (5N) respectively. The majority of the load is transmitted through the medial compartment. These observations are linked to the deformation of the medial and lateral collaterals, in addition to the anatomy of the passive soft tissues surrounding the knee. In conclusion, these findings provide tangible clinical guidance in assessing the soft tissue loads when dealing with anatomically designed total knee implants. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Effects of Knee Alignments and Toe Clip on Frontal Plane Knee Biomechanics in Cycling

    PubMed Central

    Shen, Guangping; Zhang, Songning; Bennett, Hunter J.; Martin, James C.; Crouter, Scott E.; Fitzhugh, Eugene C.

    2018-01-01

    Effects of knee alignment on the internal knee abduction moment (KAM) in walking have been widely studied. The KAM is closely associated with the development of medial knee osteoarthritis. Despite the importance of knee alignment, no studies have explored its effects on knee frontal plane biomechanics during stationary cycling. The purpose of this study was to examine the effects of knee alignment and use of a toe clip on the knee frontal plane biomechanics during stationary cycling. A total of 32 participants (11 varus, 11 neutral, and 10 valgus alignment) performed five trials in each of six cycling conditions: pedaling at 80 rpm and 0.5 kg (40 Watts), 1.0 kg (78 Watts), and 1.5 kg (117 Watts) with and without a toe clip. A motion analysis system and a customized instrumented pedal were used to collect 3D kinematic and kinetic data. A 3 × 2 × 3 (group × toe clip × workload) mixed design ANOVA was used for statistical analysis (p < 0.05). There were two different knee frontal plane loading patterns, internal abduction and adduction moment, which were affected by knee alignment type. The knee adduction angle was 12.2° greater in the varus group compared to the valgus group (p = 0.001), yet no difference was found for KAM among groups. Wearing a toe clip increased the knee adduction angle by 0.95º (p = 0.005). The findings of this study indicate that stationary cycling may be a safe exercise prescription for people with knee malalignments. In addition, using a toe clip may not have any negative effects on knee joints during stationary cycling. Key points Varus or valgus alignment did not cause increased frontal-plane knee joint loading, suggesting stationary cycling is a safe exercise. This study supports that using a toe clip did not lead to abnormal frontal-plane knee loading during stationary cycling. Two different knee frontal plane loading patterns, knee abduction and adduction moment, were observed during stationary cycling, which are likely affected by the type of knee alignment. PMID:29769833

  15. The influence of continuous versus interval walking exercise on knee joint loading and pain in patients with knee osteoarthritis.

    PubMed

    Farrokhi, Shawn; Jayabalan, Prakash; Gustafson, Jonathan A; Klatt, Brian A; Sowa, Gwendolyn A; Piva, Sara R

    2017-07-01

    To evaluate whether knee contact force and knee pain are different between continuous and interval walking exercise in patients with knee osteoarthritis (OA). Twenty seven patients with unilateral symptomatic knee OA completed two separate walking exercise sessions on a treadmill at 1.3m/s on two different days: 1) a continuous 45min walking exercise session, and 2) three 15min bouts of walking exercise separated by 1h rest periods for a total of 45min of exercise in an interval format. Estimated knee contact forces using the OpenSim software and knee pain were evaluated at baseline (1st minute of walking) and after every 15min between the continuous and interval walking conditions. A significant increase from baseline was observed in peak knee contact force during the weight-acceptance phase of gait after 30 and 45min of walking, irrespective of the walking exercise condition. Additionally, whereas continuous walking resulted in an increase in knee pain, interval walking did not lead to increased knee pain. Walking exercise durations of 30min or greater may lead to undesirable knee joint loading in patients with knee OA, while performing the same volume of exercise in multiple bouts as opposed to one continuous bout may be beneficial for limiting knee pain. Copyright © 2017. Published by Elsevier B.V.

  16. ORTHOPEDIC LEG BRACE

    NASA Technical Reports Server (NTRS)

    Myers, William Neil (Inventor)

    2005-01-01

    Knee braces generally have been rigid in both the knee bending direction and in the knee straightening direction unless a manually operated release is incorporated in them to allow the knee to bend. Desirably a braced knee joint should effectively duplicate the compound, complex, actions of a normal knee. The key to knee braces is the knee joint housing. The housing herein carries a number of cam action pawls. with teeth adapted to engage the internal teeth of a ratchet ring mounted in the housing. Cam action return springs and the shape of the cam action pawl teeth allow rotation of the ratchet ring in a leg straightening direction while still supporting a load. The leg can then be extended during walking while at the same time being prevented by the cam action pawls from buckling in the knee bending direction.

  17. Knee Joint Contact Mechanics during Downhill Gait and its Relationship with Varus/Valgus Motion and Muscle Strength in Patients with Knee Osteoarthritis

    PubMed Central

    Farrokhi, Shawn; Voycheck, Carrie A.; Gustafson, Jonathan A.; Fitzgerald, G. Kelley; Tashman, Scott

    2015-01-01

    Objective The objective of this exploratory study was to evaluate tibiofemoral joint contact point excursions and velocities during downhill gait and assess the relationship between tibiofemoral joint contact mechanics with frontal-plane knee joint motion and lower extremity muscle weakness in patients with knee osteoarthritis (OA). Methods Dynamic stereo X-ray was used to quantify tibiofemoral joint contact mechanics and frontal-plane motion during the loading response phase of downhill gait in 11 patients with knee OA and 11 control volunteers. Quantitative testing of the quadriceps and the hip abductor muscles was also performed. Group differences in contact mechanics and frontal-plane motion excursions were compared using analysis of covariance with adjustments for body mass index. Differences in strength were compared using independent sample t-tests. Additionally, linear associations between contact mechanics with frontal-plane knee motion and muscle strength were evaluated using Pearson's correlation coefficients. Results Patients with knee OA demonstrated larger medial/lateral joint contact point excursions (p<0.02) and greater heel-strike joint contact point velocities (p<0.05) for the medial and lateral compartments compared to the control group. The peak medial/lateral joint contact point velocity of the medial compartment was also greater for patients with knee OA compared to their control counterparts (p=0.02). Additionally, patients with knee OA demonstrated significantly increased frontal-plane varus motion excursions (p<0.01) and greater quadriceps and hip abductor muscle weakness (p=0.03). In general, increased joint contact point excursions and velocities in patients with knee OA were linearly associated with greater frontal-plane varus motion excursions (p<0.04) but not with quadriceps or hip abductor strength. Conclusion Altered contact mechanics in patients with knee OA may be related to compromised frontal-plane joint stability but not with deficits in muscle strength. PMID:27030846

  18. Technical feasibility of personalized articulating knee joint distraction for treatment of tibiofemoral osteoarthritis.

    PubMed

    Struik, T; Jaspers, J E N; Besselink, N J; van Roermund, P M; Plomp, S; Rudert, M J; Lafeber, F P J G; Mastbergen, S C

    2017-11-01

    Knee osteoarthritis is a highly prevalent degenerative joint disorder characterized by joint tissue damage and pain. Knee joint distraction has been introduced as a joint preserving surgical procedure to postpone knee arthroplasty. An often used standard externally fixation device for distraction poses a burden to patients due to the absence of joint flexion during the 6weeks treatment. Therefore, a personalized articulating distraction device was developed. The aim of this study was to test technical feasibility of this device. Based on an often applied rigid device, using equal bone pin positions and connectors, a hinge mechanism was developed consisting of a cam-following system for reproducing the complex joint-specific knee kinematics. In support, a device was developed for capturing the joint-specific sagittal plane articulation. The obtained kinematic data were translated into joint-specific cam shapes that were installed bilaterally in the hinge mechanism of the distraction device, as such providing personalized knee motion. Distraction of 5mm was performed within a range of motion of 30deg. joint flexion. Pre-clinical evaluation of the working principle was performed on human cadaveric legs and system stiffness characteristics were biomechanically evaluated. The desired range of motion was obtained and distraction was maintained under physiologically representative loading. Moreover, the joint-specific approach demonstrated tolerance of deviations from anatomical and alignment origin during initial placement of the developed distraction device. Articulation during knee distraction is considered technically feasible and has potential to decrease burden and improve acceptance of distraction therapy. Testing of clinical feasibility is warranted. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. The Influence of Articular Cartilage Thickness Reduction on Meniscus Biomechanics

    PubMed Central

    Łuczkiewicz, Piotr; Daszkiewicz, Karol; Chróścielewski, Jacek; Witkowski, Wojciech; Winklewski, Pawel J.

    2016-01-01

    Objective Evaluation of the biomechanical interaction between meniscus and cartilage in medial compartment knee osteoarthritis. Methods The finite element method was used to simulate knee joint contact mechanics. Three knee models were created on the basis of knee geometry from the Open Knee project. We reduced the thickness of medial cartilages in the intact knee model by approximately 50% to obtain a medial knee osteoarthritis (OA) model. Two variants of medial knee OA model with congruent and incongruent contact surfaces were analysed to investigate the influence of congruency. A nonlinear static analysis for one compressive load case was performed. The focus of the study was the influence of cartilage degeneration on meniscal extrusion and the values of the contact forces and contact areas. Results In the model with incongruent contact surfaces, we observed maximal compressive stress on the tibial plateau. In this model, the value of medial meniscus external shift was 95.3% greater, while the contact area between the tibial cartilage and medial meniscus was 50% lower than in the congruent contact surfaces model. After the non-uniform reduction of cartilage thickness, the medial meniscus carried only 48.4% of load in the medial compartment in comparison to 71.2% in the healthy knee model. Conclusions We have shown that the change in articular cartilage geometry may significantly reduce the role of meniscus in load transmission and the contact area between the meniscus and cartilage. Additionally, medial knee OA may increase the risk of meniscal extrusion in the medial compartment of the knee joint. PMID:27936066

  20. Joint contact loading in forefoot and rearfoot strike patterns during running.

    PubMed

    Rooney, Brandon D; Derrick, Timothy R

    2013-09-03

    Research concerning forefoot strike pattern (FFS) versus rearfoot strike pattern (RFS) running has focused on the ground reaction force even though internal joint contact forces are a more direct measure of the loads responsible for injury. The main purpose of this study was to determine the internal loading of the joints for each strike pattern. A secondary purpose was to determine if converted FFS and RFS runners can adequately represent habitual runners with regards to the internal joint loading. Using inverse dynamics to calculate the net joint moments and reaction forces and optimization techniques to estimate muscle forces, we determined the axial compressive loading at the ankle, knee, and hip. Subjects consisted of 15 habitual FFS and 15 habitual RFS competitive runners. Each subject ran at a preferred running velocity with their habitual strike pattern and then converted to the opposite strike pattern. Plantar flexor muscle forces and net ankle joint moments were greater in the FFS running compared to the RFS running during the first half of the stance phase. The average contact forces during this period increased by 41.7% at the ankle and 14.4% at the knee joint during FFS running. Peak ankle joint contact force was 1.5 body weights greater during FFS running (p<0.05). There was no evidence to support a difference between habitual and converted running for joint contact forces. The increased loading at the ankle joint for FFS is an area of concern for individuals considering altering their foot strike pattern. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Discrete and continuous joint coupling relationships in uninjured recreational runners.

    PubMed

    Dierks, Tracy A; Davis, Irene

    2007-06-01

    Abnormal joint coupling is thought to be related to overuse injuries in runners. However, researchers do not yet know what constitutes normal joint coupling during running, which makes abnormal coupling difficult to define. Lower extremity kinematics were collected from 40 recreational runners during stance. Joint coupling methods were applied and, for each method, means and both within- and between-subject variability were calculated. The 95% confidence interval was used to compare differences across coupling relationships and periods of stance. Timing between rearfoot eversion, tibial internal rotation, and knee flexion were relatively synchronous while relationships involving knee internal rotation were more asynchronous. The excursion ratios showed that every 2 degrees of rearfoot eversion was coupled with 1 degrees of both tibial internal rotation and knee internal rotation. Vector coding results showed that just beyond maximum loading, all joint coupling relationships resulted in relatively equal amounts of motion, while the within-subject variability was similar throughout stance. The continuous relative phase results showed that the most out-of-phase coupling occurred in the periods around heel-strike and toe-off while the most in-phase coupling occurred in the period just beyond maximum loading of the leg. The continuous relative phase within-subject variability was greatest at the periods around heel-strike and toe-off and smallest just beyond maximum loading. With a better understanding of joint coupling in uninjured runners, these data will help to serve as a reference for future studies investigating the relationship between running injuries and abnormal joint coupling.

  2. Investigating the primary stability of the transversal support tibial plateau concept to retain both cruciate ligaments during total knee arthroplasty.

    PubMed

    Nowakowski, Andrej M; Stangel, Melanie; Grupp, Thomas M; Valderrabano, Victor

    2012-09-27

    The important roles of the anterior cruciate ligament regarding knee stability, physiologic kinematics, and proprioception are unquestioned. Thus, various efforts have been made to retain the ACL during total knee arthroplasty (TKA). Neither of the existing solutions to this problem, i.e. bicruciate retaining prostheses and implantation of two unicondylar prostheses, has been successful because of concept-specific problems as well as general difficulties with implant fixation. The new transversal support tibial plateau concept is a prosthesis of two individual joint surfaces reinforced beneath the articular line by joint surface supports and buttressed by a single transversal support. This configuration, which enables retention of both cruciate ligaments, should provide good bone fixation and ensure long-term alignment of the individual joint surfaces. In the current study, four prototypes based on this novel concept were developed and the resulting primary stability was analyzed using adapted load testing. The test set-up, with the model-loading of specially prepared Sawbones® and a sinusoidal oscillating load transmission with 25 000 cycles over 10 increasing load levels, achieved subsidence, which enabled comparison of the four different model variants regarding primary stability in view of bone anchoring. The model variant (TSmobile) that allowed transverse glide of the joint surface supports along the transversal support revealed the largest subsidence. A rigid attachment of the joint surface supports of the transversal support tibial plateau thus appears to offer increased primary stability regarding bone anchoring.

  3. Altered control strategy between leading and trailing leg increases knee adduction moment in the elderly while descending stairs.

    PubMed

    Karamanidis, Kiros; Arampatzis, Adamantios

    2011-02-24

    The aim of the study was to examine the external knee adduction moments in a group of older and younger adults while descending stairs and thus the possibility of an increased risk of knee osteoarthritis due to altered knee joint loading in the elderly. Twenty-seven older and 16 younger adults descended a purpose-built staircase. A motion capture system and a force plate were used to determine the subjects' 3D kinematics and ground reaction forces (GRF) during locomotion. Calculation of the leg kinematics and kinetics was done by means of a rigid, three-segment, 3D leg model. In the initial portion of the support phase, older adults showed a more medio-posterior GRF vector relative to the ankle joint, leading to lower ankle joint moments (P<0.05). At the knee, the older adults demonstrated a more medio-posterior directed GRF vector, increasing in knee flexion and adduction in the second part of the single support phase (P<0.05). Further, GRF magnitude was lower in the initial and higher in the mid-portions of the support phase for the elderly (P<0.05). The results show that older adults descend stairs by using the trailing leg before the initiation of the double support phase more compared to the younger ones. The consequence of this altered control strategy while stepping down is a more medially directed GRF vector increasing the magnitude of external knee adduction moment in the elderly. The observed changes between leading and trailing leg in the elderly may cause a redistribution of the mechanical load at the tibiofemoral joint, affecting the initiation and progression of knee osteoarthritis in the elderly. Copyright © 2010 Elsevier Ltd. All rights reserved.

  4. Finite Element Model of the Knee for Investigation of Injury Mechanisms: Development and Validation

    PubMed Central

    Kiapour, Ali; Kiapour, Ata M.; Kaul, Vikas; Quatman, Carmen E.; Wordeman, Samuel C.; Hewett, Timothy E.; Demetropoulos, Constantine K.; Goel, Vijay K.

    2014-01-01

    Multiple computational models have been developed to study knee biomechanics. However, the majority of these models are mainly validated against a limited range of loading conditions and/or do not include sufficient details of the critical anatomical structures within the joint. Due to the multifactorial dynamic nature of knee injuries, anatomic finite element (FE) models validated against multiple factors under a broad range of loading conditions are necessary. This study presents a validated FE model of the lower extremity with an anatomically accurate representation of the knee joint. The model was validated against tibiofemoral kinematics, ligaments strain/force, and articular cartilage pressure data measured directly from static, quasi-static, and dynamic cadaveric experiments. Strong correlations were observed between model predictions and experimental data (r > 0.8 and p < 0.0005 for all comparisons). FE predictions showed low deviations (root-mean-square (RMS) error) from average experimental data under all modes of static and quasi-static loading, falling within 2.5 deg of tibiofemoral rotation, 1% of anterior cruciate ligament (ACL) and medial collateral ligament (MCL) strains, 17 N of ACL load, and 1 mm of tibiofemoral center of pressure. Similarly, the FE model was able to accurately predict tibiofemoral kinematics and ACL and MCL strains during simulated bipedal landings (dynamic loading). In addition to minimal deviation from direct cadaveric measurements, all model predictions fell within 95% confidence intervals of the average experimental data. Agreement between model predictions and experimental data demonstrates the ability of the developed model to predict the kinematics of the human knee joint as well as the complex, nonuniform stress and strain fields that occur in biological soft tissue. Such a model will facilitate the in-depth understanding of a multitude of potential knee injury mechanisms with special emphasis on ACL injury. PMID:24763546

  5. Non-driving intersegmental knee moments in cycling computed using a model that includes three-dimensional kinematics of the shank/foot and the effect of simplifying assumptions.

    PubMed

    Gregersen, Colin S; Hull, M L

    2003-06-01

    Assessing the importance of non-driving intersegmental knee moments (i.e. varus/valgus and internal/external axial moments) on over-use knee injuries in cycling requires the use of a three-dimensional (3-D) model to compute these loads. The objectives of this study were: (1) to develop a complete, 3-D model of the lower limb to calculate the 3-D knee loads during pedaling for a sample of the competitive cycling population, and (2) to examine the effects of simplifying assumptions on the calculations of the non-driving knee moments. The non-driving knee moments were computed using a complete 3-D model that allowed three rotational degrees of freedom at the knee joint, included the 3-D inertial loads of the shank/foot, and computed knee loads in a shank-fixed coordinate system. All input data, which included the 3-D segment kinematics and the six pedal load components, were collected from the right limb of 15 competitive cyclists while pedaling at 225 W and 90 rpm. On average, the peak varus and internal axial moments of 7.8 and 1.5 N m respectively occurred during the power stroke whereas the peak valgus and external axial moments of 8.1 and 2.5 N m respectively occurred during the recovery stroke. However, the non-driving knee moments were highly variable between subjects; the coefficients of variability in the peak values ranged from 38.7% to 72.6%. When it was assumed that the inertial loads of the shank/foot for motion out of the sagittal plane were zero, the root-mean-squared difference (RMSD) in the non-driving knee moments relative to those for the complete model was 12% of the peak varus/valgus moment and 25% of the peak axial moment. When it was also assumed that the knee joint was revolute with the flexion/extension axis perpendicular to the sagittal plane, the RMSD increased to 24% of the peak varus/valgus moment and 204% of the peak axial moment. Thus, the 3-D orientation of the shank segment has a major affect on the computation of the non-driving knee moments, while the inertial contributions to these loads for motions out of the sagittal plane are less important.

  6. Simulation of in vivo dynamics during robot assisted joint movement.

    PubMed

    Bobrowitsch, Evgenij; Lorenz, Andrea; Wülker, Nikolaus; Walter, Christian

    2014-12-16

    Robots are very useful tools in orthopedic research. They can provide force/torque controlled specimen motion with high repeatability and precision. A method to analyze dissipative energy outcome in an entire joint was developed in our group. In a previous study, a sheep knee was flexed while axial load remained constant during the measurement of dissipated energy. We intend to apply this method for the investigation of osteoarthritis. Additionally, the method should be improved by simulation of in vivo knee dynamics. Thus, a new biomechanical testing tool will be developed for analyzing in vitro joint properties after different treatments. Discretization of passive knee flexion was used to construct a complex flexion movement by a robot and simulate altering axial load similar to in vivo sheep knee dynamics described in a previous experimental study. The robot applied an in vivo like axial force profile with high reproducibility during the corresponding knee flexion (total standard deviation of 0.025 body weight (BW)). A total residual error between the in vivo and simulated axial force was 0.16 BW. Posterior-anterior and medio-lateral forces were detected by the robot as a backlash of joint structures. Their curve forms were similar to curve forms of corresponding in vivo measured forces, but in contrast to the axial force, they showed higher total standard deviation of 0.118 and 0.203 BW and higher total residual error of 0.79 and 0.21 BW for posterior-anterior and medio-lateral forces respectively. We developed and evaluated an algorithm for the robotic simulation of complex in vivo joint dynamics using a joint specimen. This should be a new biomechanical testing tool for analyzing joint properties after different treatments.

  7. Ultrasound monitoring of inter-knee distances during gait.

    PubMed

    Lai, Daniel T H; Wrigley, Tim V; Palaniswami, M

    2009-01-01

    Knee osteoarthritis is an extremely common, debilitating disease associated with pain and loss of function. There is considerable interest in monitoring lower limb alignment due to its close association with joint overload leading to disease progression. The effects of gait modifications that can lower joint loading are of particular interest. Here we describe an ultrasound-based system for monitoring an important aspect of dynamic lower limb alignment, the inter-knee distance during walking. Monitoring this gait parameter should facilitate studies in reducing knee loading, a primary risk factor of knee osteoarthritis progression. The portable device is composed of an ultrasound sensor connected to an Intel iMote2 equipped with Bluetooth wireless capability. Static tests and calibration results show that the sensor possesses an effective beam envelope of 120 degrees, with maximum distance errors of 10% at the envelope edges. Dynamic walking trials reveal close correlation of inter-knee distance trends between that measured by an optical system (Optotrak Certus NDI) and the sensor device. The maximum average root mean square error was found to be 1.46 cm. Future work will focus on improving the accuracy of the device.

  8. Knock knee and the gait of six-year-old children.

    PubMed

    Pretkiewicz-Abacjew, E

    2003-06-01

    Knock knee (genu valgum) interferes with the locomotive and supporting function of the lower limb. In static conditions the load-bearing axis of the valgus limb is displaced laterally in relation to the middle of the joint, causing the knee joint, the ankle joint, and the foot as a whole to be weighted in the wrong way. The purpose of this work is to examine the influence of knock knee on gait kinematics. The gait of twenty-two 6-year-old children of both sexes in whom knock knee had been medically diagnosed was compared with the gait of 33 children of the same age whose knee joints conformed to the norm in formation and position. Gait was recorded separately for the sagittal and the frontal planes, using a video-computer system. The results of the examination indicated statistically significant differences in the gait of the two groups of children. These differences related mainly to the time features of gait and to data on the angles in the knee and ankle joints. Although the results obtained for other features of gait did not reveal statistical differences, these did indicate that the children with knock knee walked more slowly and with a lower cadence. The results indicate that knock knee in 6-year-old children has an adverse impact on the mechanics of the lower limb joints in gait and causes a deterioration in gait quality. Thus knock knee in children should not be treated merely as a superficial defect but should be subject to therapy and, more importantly, taken into account when introducing children to early sports training.

  9. Effects of Cementing on Ligament Balance During Total Knee Arthroplasty.

    PubMed

    Chow, Jimmy; Wang, Kevin; Elson, Leah; Anderson, Christopher; Roche, Martin

    2017-05-01

    Complications related to joint imbalance may contribute to some of the most predominant modes of failure in total knee arthroplasty (TKA). These complications include instability, aseptic loosening, asymmetric component wear, and idiopathic pain. Fixation may represent a step that introduces unchecked variability into the procedure and may contribute to the incidence of joint imbalance-related complications. The ability to quantify in vivo loading in the medial and lateral compartments would allow for the ability to confirm balance after fixation and prior to wound closure. This retrospective study sought to capture any variability and imbalance associated with cementing technique. A total of 93 patients underwent sensor-assisted TKA. All patients were confirmed to have quantifiably balanced joints prior to cementation. After cementing and final component placement, the sensor was reinserted into the joint to capture any cementation-induced changes in loading. Imbalance was observed in 44% of patients after cementation. There was no difference in the proportion of imbalance due to surgeon experience (P=.456), cement type (P=.429), or knee system (P=.792). A majority of knees exhibited loading increase in the medial compartment. It was concluded that cementation technique contributes to a significant amount of balance-related variability at the fixation stage of the procedure. The use of the sensor in this study allowed for the correction of all instances of imbalance prior to closure. More objective methods of balance verification may be important for ensuring optimal surgical outcomes. [Orthopedics. 2017; 40(3):e455-e459.]. Copyright 2017, SLACK Incorporated.

  10. Modelling knee flexion effects on joint power absorption and adduction moment.

    PubMed

    Nagano, Hanatsu; Tatsumi, Ichiroh; Sarashina, Eri; Sparrow, W A; Begg, Rezaul K

    2015-12-01

    Knee osteoarthritis is commonly associated with ageing and long-term walking. In this study the effects of flexing motions on knee kinetics during stance were simulated. Extended knees do not facilitate efficient loading. It was therefore, hypothesised that knee flexion would promote power absorption and negative work, while possibly reducing knee adduction moment. Three-dimensional (3D) position and ground reaction forces were collected from the right lower limb stance phase of one healthy young male subject. 3D position was sampled at 100 Hz using three Optotrak Certus (Northern Digital Inc.) motion analysis camera units, set up around an eight metre walkway. Force plates (AMTI) recorded ground reaction forces for inverse dynamics calculations. The Visual 3D (C-motion) 'Landmark' function was used to change knee joint positions to simulate three knee flexion angles during static standing. Effects of the flexion angles on joint kinetics during the stance phase were then modelled. The static modelling showed that each 2.7° increment in knee flexion angle produced 2.74°-2.76° increments in knee flexion during stance. Increased peak extension moment was 6.61 Nm per 2.7° of increased knee flexion. Knee flexion enhanced peak power absorption and negative work, while decreasing adduction moment. Excessive knee extension impairs quadriceps' power absorption and reduces eccentric muscle activity, potentially leading to knee osteoarthritis. A more flexed knee is accompanied by reduced adduction moment. Research is required to determine the optimum knee flexion to prevent further damage to knee-joint structures affected by osteoarthritis. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Effect of rocker-soled shoes on parameters of knee joint load in knee osteoarthritis.

    PubMed

    Madden, Elizabeth G; Kean, Crystal O; Wrigley, Tim V; Bennell, Kim L; Hinman, Rana S

    2015-01-01

    This study evaluated the immediate effects of rocker-soled shoes on parameters of the knee adduction moment (KAM) and pain in individuals with knee osteoarthritis (OA). Three-dimensional gait analysis was performed on 30 individuals (mean (SD): age, 61 (7) yr; 15 (50%) male) with radiographic and symptomatic knee OA under three walking conditions in a randomized order: i) wearing rocker-soled shoes (Skechers Shape-ups), ii) wearing non-rocker-soled shoes (ASICS walking shoes), and iii) barefoot. Peak KAM and KAM angular impulse were measured as primary indicators of knee load distribution. Secondary measures included the knee flexion moment (KFM) and knee pain during walking. Peak KAM was significantly lower when wearing the rocker-soled shoes compared with that when wearing the non-rocker-soled shoes (mean difference (95% confidence interval), -0.27 (-0.42 to -0.12) N·m/BW × Ht%; P < 0.001). Post hoc tests revealed no significant difference in KAM impulse between rocker-soled and non-rocker-soled shoe conditions (P = 0.13). Both peak KAM and KAM impulse were significantly higher during both shoe conditions compared with those during the barefoot condition (P < 0.001). There were no significant differences in KFM (P = 0.36) or knee pain (P = 0.89) between conditions. Rocker-soled shoes significantly reduced peak KAM when compared with non-rocker-soled shoes, without a concomitant change in KFM, and thus may potentially reduce medial knee joint loading. However, KAM parameters in the rocker-soled shoes remained significantly higher than those during barefoot walking. Wearing rocker-soled shoes did not have a significant immediate effect on walking pain. Further research is required to evaluate whether rocker-soled shoes can influence symptoms and progression of knee OA with prolonged wear.

  12. Three-Dimensional Biomechanical Analysis of Rearfoot and Forefoot Running.

    PubMed

    Knorz, Sebastian; Kluge, Felix; Gelse, Kolja; Schulz-Drost, Stefan; Hotfiel, Thilo; Lochmann, Matthias; Eskofier, Björn; Krinner, Sebastian

    2017-07-01

    In the running community, a forefoot strike (FFS) pattern is increasingly preferred compared with a rearfoot strike (RFS) pattern. However, it has not been fully understood which strike pattern may better reduce adverse joint forces within the different joints of the lower extremity. To analyze the 3-dimensional (3D) stress pattern in the ankle, knee, and hip joint in runners with either a FFS or RFS pattern. Descriptive laboratory study. In 22 runners (11 habitual rearfoot strikers, 11 habitual forefoot strikers), RFS and FFS patterns were compared at 3.0 m/s (6.7 mph) on a treadmill with integrated force plates and a 3D motion capture analysis system. This combined analysis allowed characterization of the 3D biomechanical forces differentiated for the ankle, knee, and hip joint. The maximum peak force (MPF) and maximum loading rate (LR) were determined in their 3 ordinal components: vertical, anterior-posterior (AP), and medial-lateral (ML). For both strike patterns, the vertical components of the MPF and LR were significantly greater than their AP or ML components. In the vertical axis, FFS was generally associated with a greater MPF but significantly lower LR in all 3 joints. The AP components of MPF and LR were significantly lower for FFS in the knee joint but significantly greater in the ankle and hip joints. The ML components of MPF and LR tended to be greater for FFS but mostly did not reach a level of significance. FFS and RFS were associated with different 3D stress patterns in the ankle, knee, and hip joint, although there was no global advantage of one strike pattern over the other. The multimodal individual assessment for the different anatomic regions demonstrated that FFS seems favorable for patients with unstable knee joints in the AP axis and RFS may be recommended for runners with unstable ankle joints. Different strike patterns show different 3D stress in joints of the lower extremity. Due to either rehabilitation after injuries or training in running sports, rearfoot or forefoot running should be preferred to prevent further damage or injuries caused by inadequate biomechanical load. Runners with a history of knee joint injuries may benefit from FFS whereas RFS may be favorable for runners with a history of ankle joint injuries.

  13. Three-Dimensional Biomechanical Analysis of Rearfoot and Forefoot Running

    PubMed Central

    Knorz, Sebastian; Kluge, Felix; Gelse, Kolja; Schulz-Drost, Stefan; Hotfiel, Thilo; Lochmann, Matthias; Eskofier, Björn; Krinner, Sebastian

    2017-01-01

    Background: In the running community, a forefoot strike (FFS) pattern is increasingly preferred compared with a rearfoot strike (RFS) pattern. However, it has not been fully understood which strike pattern may better reduce adverse joint forces within the different joints of the lower extremity. Purpose: To analyze the 3-dimensional (3D) stress pattern in the ankle, knee, and hip joint in runners with either a FFS or RFS pattern. Study Design: Descriptive laboratory study. Methods: In 22 runners (11 habitual rearfoot strikers, 11 habitual forefoot strikers), RFS and FFS patterns were compared at 3.0 m/s (6.7 mph) on a treadmill with integrated force plates and a 3D motion capture analysis system. This combined analysis allowed characterization of the 3D biomechanical forces differentiated for the ankle, knee, and hip joint. The maximum peak force (MPF) and maximum loading rate (LR) were determined in their 3 ordinal components: vertical, anterior-posterior (AP), and medial-lateral (ML). Results: For both strike patterns, the vertical components of the MPF and LR were significantly greater than their AP or ML components. In the vertical axis, FFS was generally associated with a greater MPF but significantly lower LR in all 3 joints. The AP components of MPF and LR were significantly lower for FFS in the knee joint but significantly greater in the ankle and hip joints. The ML components of MPF and LR tended to be greater for FFS but mostly did not reach a level of significance. Conclusion: FFS and RFS were associated with different 3D stress patterns in the ankle, knee, and hip joint, although there was no global advantage of one strike pattern over the other. The multimodal individual assessment for the different anatomic regions demonstrated that FFS seems favorable for patients with unstable knee joints in the AP axis and RFS may be recommended for runners with unstable ankle joints. Clinical Relevance: Different strike patterns show different 3D stress in joints of the lower extremity. Due to either rehabilitation after injuries or training in running sports, rearfoot or forefoot running should be preferred to prevent further damage or injuries caused by inadequate biomechanical load. Runners with a history of knee joint injuries may benefit from FFS whereas RFS may be favorable for runners with a history of ankle joint injuries. PMID:28812039

  14. An Investigation into the Relation between the Technique of Movement and Overload in Step Aerobics

    PubMed Central

    Wysocka, Katarzyna

    2017-01-01

    The aim of this research was to determine the features of a step workout technique which may be related to motor system overloading in step aerobics. Subjects participating in the research were instructors (n = 15) and students (n = 15) without any prior experience in step aerobics. Kinematic and kinetic data was collected with the use of the BTS SMART system comprised of 6 calibrated video cameras and two Kistler force plates. The subjects' task was to perform basic steps. The following variables were analyzed: vertical, anteroposterior, and mediolateral ground reaction forces; foot flexion and abduction and adduction angles; knee joint flexion angle; and trunk flexion angle in the sagittal plane. The angle of a foot adduction recorded for the instructors was significantly smaller than that of the students. The knee joint angle while stepping up was significantly higher for the instructors compared to that for the students. Our research confirmed that foot dorsal flexion and adduction performed while stepping up increased load on the ankle joint. Both small and large angles of knee flexion while stepping up and down resulted in knee joint injuries. A small trunk flexion angle in the entire cycle of step workout shut down dorsal muscles, which stopped suppressing the load put on the spine. PMID:28348501

  15. Running stability is enhanced by a proximo-distal gradient in joint neuromechanical control.

    PubMed

    Daley, M A; Felix, G; Biewener, A A

    2007-02-01

    We currently know little about how animals achieve dynamic stability when running over uneven and unpredictable terrain, often characteristic of their natural environment. Here we investigate how limb and joint mechanics of an avian biped, the helmeted guinea fowl Numida meleagris, respond to an unexpected drop in terrain during running. In particular, we address how joint mechanics are coordinated to achieve whole limb dynamics. Based on muscle-tendon architecture and previous studies of steady and incline locomotion, we hypothesize a proximo-distal gradient in joint neuromechanical control. In this motor control strategy, (1) proximal muscles at the hip and knee joints are controlled primarily in a feedforward manner and exhibit load-insensitive mechanical performance, and (2) distal muscles at the ankle and tarsometatarso-phalangeal (TMP) joints are highly load-sensitive, due to intrinsic mechanical effects and rapid, higher gain proprioceptive feedback. Limb kinematics and kinetics during the unexpected perturbation reveal that limb retraction, controlled largely by the hip, remains similar to level running throughout the perturbed step, despite altered limb loading. Individual joints produce or absorb energy during both level and perturbed running steps, such that the net limb work depends on the balance of energy among the joints. The hip maintains the same mechanical role regardless of limb loading, whereas the ankle and TMP switch between spring-like or damping function depending on limb posture at ground contact. Initial knee angle sets limb posture and alters the balance of work among the joints, although the knee contributes little work itself. This distribution of joint function results in posture-dependent changes in work performance of the limb, which allow guinea fowl to rapidly produce or absorb energy in response to the perturbation. The results support the hypothesis that a proximo-distal gradient exists in limb neuromuscular performance and motor control. This control strategy allows limb cycling to remain constant, whereas limb posture, loading and energy performance are interdependent. We propose that this control strategy provides simple, rapid mechanisms for managing energy and controlling velocity when running over rough terrain.

  16. Running stability is enhanced by a proximo-distal gradient in joint neuromechanical control

    PubMed Central

    Daley, M. A.; Felix, G.; Biewener, A. A.

    2008-01-01

    Summary We currently know little about how animals achieve dynamic stability when running over uneven and unpredictable terrain, often characteristic of their natural environment. Here we investigate how limb and joint mechanics of an avian biped, the helmeted guinea fowl Numida meleagris, respond to an unexpected drop in terrain during running. In particular, we address how joint mechanics are coordinated to achieve whole limb dynamics. Based on muscle–tendon architecture and previous studies of steady and incline locomotion, we hypothesize a proximo-distal gradient in joint neuromechanical control. In this motor control strategy, (1) proximal muscles at the hip and knee joints are controlled primarily in a feedforward manner and exhibit load-insensitive mechanical performance, and (2) distal muscles at the ankle and tarsometatarso-phalangeal (TMP) joints are highly load-sensitive, due to intrinsic mechanical effects and rapid, higher gain proprioceptive feedback. Limb kinematics and kinetics during the unexpected perturbation reveal that limb retraction, controlled largely by the hip, remains similar to level running throughout the perturbed step, despite altered limb loading. Individual joints produce or absorb energy during both level and perturbed running steps, such that the net limb work depends on the balance of energy among the joints. The hip maintains the same mechanical role regardless of limb loading, whereas the ankle and TMP switch between spring-like or damping function depending on limb posture at ground contact. Initial knee angle sets limb posture and alters the balance of work among the joints, although the knee contributes little work itself. This distribution of joint function results in posture-dependent changes in work performance of the limb, which allow guinea fowl to rapidly produce or absorb energy in response to the perturbation. The results support the hypothesis that a proximo-distal gradient exists in limb neuromuscular performance and motor control. This control strategy allows limb cycling to remain constant, whereas limb posture, loading and energy performance are interdependent. We propose that this control strategy provides simple, rapid mechanisms for managing energy and controlling velocity when running over rough terrain. PMID:17234607

  17. Gait and muscle activation changes in men with knee osteoarthritis.

    PubMed

    Liikavainio, Tuomas; Bragge, Timo; Hakkarainen, Marko; Karjalainen, Pasi A; Arokoski, Jari P

    2010-01-01

    The aim was to examine the biomechanics of level- and stair-walking in men with knee osteoarthritis (OA) at different pre-determined gait speeds and to compare the results with those obtained from healthy control subjects. Special emphasis was placed on the estimation of joint loading. Fifty-four men with knee OA (50-69 years) and 53 healthy age- and sex-matched controls were enrolled in the study. The participants walked barefoot in the laboratory (1.2 m/s+/-5%), corridor (1.2; 1.5 and 1.7 m/s+/-5%), and climbing and coming down stairs (0.5 and 0.8 m/s+/-5%) separately. Joint loading was assessed with skin mounted accelerometers (SMAs) attached just above and below the more affected knee joint. The 3-D ground reaction forces (GRFs) and muscle activation with surface-electromyography (EMG) from vastus medialis (VM) and biceps femoris (BF) were also measured simultaneously. There were no differences in SMA variables between groups during level-walking, but maximal loading rate (LR(max)) was higher bilaterally in the controls (P<.05). Patients loaded their lower extremity more forcefully especially during stair descent at faster speed. The distinctions in muscle activation both at level- and stair ambulation in VM and BF muscles revealed that the patients used different strategies to execute the same walking tasks. It is concluded that the differences in measured SMA and GRF parameters between the knee OA patients and the controls were only minor at constant gait speeds. It is speculated that the faster speeds in the stair descent subjected the compensatory mechanisms to the maximum highlighting the differences between groups.

  18. Selective contribution of each hamstring muscle to anterior cruciate ligament protection and tibiofemoral joint stability in leg-extension exercise: a simulation study.

    PubMed

    Biscarini, Andrea; Botti, Fabio Massimo; Pettorossi, Vito Enrico

    2013-09-01

    A biomechanical model was developed to simulate the selective effect of the co-contraction force provided by each hamstring muscle on the shear and compressive tibiofemoral joint reaction forces, during open kinetic-chain knee-extension exercises. This model accounts for instantaneous values of knee flexion angle [Formula: see text], angular velocity and acceleration, and for changes in magnitude, orientation, and application point of external resistance. The tibiofemoral shear force (TFSF) largely determines the tensile force on anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL). Biceps femoris is the most effective hamstring muscle in decreasing the ACL-loading TFSF developed by quadriceps contractions for [Formula: see text]. In this range, the semimembranosus generates the dominant tibiofemoral compressive force, which enhances joint stability, opposes anterior/posterior tibial translations, and protects cruciate ligaments. The semitendinosus force provides the greatest decreasing gradient of ACL-loading TFSF for [Formula: see text], and the greatest increasing gradient of tibiofemoral compressive force for [Formula: see text]. However, semitendinosus efficacy is strongly limited by its small physiological section. Hamstring muscles behave as a unique muscle in enhancing the PCL-loading TFSF produced by quadriceps contractions for [Formula: see text]. The levels of hamstrings co-activation that suppress the ACL-loading TFSF considerably shift when the knee angular acceleration is changed while maintaining the same level of knee extensor torque by a concurrent adjustment in the magnitude of external resistance. The knowledge of the specific role and the optimal activation level of each hamstring muscle in ACL protection and tibiofemoral stability are fundamental for planning safe and effective rehabilitative knee-extension exercises.

  19. The role of knee alignment in disease progression and functional decline in knee osteoarthritis.

    PubMed

    Sharma, L; Song, J; Felson, D T; Cahue, S; Shamiyeh, E; Dunlop, D D

    2001-07-11

    Knee osteoarthritis (OA) is a leading cause of disability in older persons. Few risk factors for disease progression or functional decline have been identified. Hip-knee-ankle alignment influences load distribution at the knee; varus and valgus alignment increase medial and lateral load, respectively. To test the hypotheses that (1) varus alignment increases risk of medial knee OA progression during the subsequent 18 months, (2) valgus alignment increases risk of subsequent lateral knee OA progression, (3) greater severity of malalignment is associated with greater subsequent loss of joint space, and (4) greater burden of malalignment is associated with greater subsequent decline in physical function. Prospective longitudinal cohort study conducted March 1997 to March 2000 at an academic medical center in Chicago, Ill. A total of 237 persons recruited from the community with primary knee OA, defined by presence of definite tibiofemoral osteophytes and at least some difficulty with knee-requiring activity; 230 (97%) completed the study. Progression of OA, defined as a 1-grade increase in severity of joint space narrowing on semiflexed, fluoroscopically confirmed knee radiographs; change in narrowest joint space width; and change in physical function between baseline and 18 months, compared by knee alignment at baseline. Varus alignment at baseline was associated with a 4-fold increase in the odds of medial progression, adjusting for age, sex, and body mass index (adjusted odds ratio [OR], 4.09; 95% confidence interval [CI], 2.20-7.62). Valgus alignment at baseline was associated with a nearly 5-fold increase in the odds of lateral progression (adjusted OR, 4.89; 95% CI, 2.13-11.20). Severity of varus correlated with greater medial joint space loss during the subsequent 18 months (R = 0.52; 95% CI, 0.40-0.62 in dominant knees), and severity of valgus correlated with greater subsequent lateral joint space loss (R = 0.35; 95% CI, 0.21-0.47 in dominant knees). Having alignment of more than 5 degrees (in either direction) in both knees at baseline was associated with significantly greater functional deterioration during the 18 months than having alignment of 5 degrees or less in both knees, after adjusting for age, sex, body mass index, and pain. This is, to our knowledge, the first demonstration that in primary knee OA varus alignment increases risk of medial OA progression, that valgus alignment increases risk of lateral OA progression, that burden of malalignment predicts decline in physical function, and that these effects can be detected after as little as 18 months of observation.

  20. Three-Dimensional Lower Extremity Joint Loading in a Carved Ski and Snowboard Turn: A Pilot Study

    PubMed Central

    Müller, Erich

    2014-01-01

    A large number of injuries to the lower extremity occur in skiing and snowboarding. Due to the difficulty of collecting 3D kinematic and kinetic data with high accuracy, a possible relationship between injury statistic and joint loading has not been studied. Therefore, the purpose of the current study was to compare ankle and knee joint loading at the steering leg between carved ski and snowboard turns. Kinetic data were collected using mobile force plates mounted under the toe and heel part of the binding on skies or snowboard (KISTLER). Kinematic data were collected with five synchronized, panning, tilting, and zooming cameras. An extended version of the Yeadon model was applied to calculate inertial properties of the segments. Ankle and knee joint forces and moments were calculated using inverse dynamic analysis. Results showed higher forces along the longitudinal axis in skiing and similar forces for skiing and snowboarding in anterior-posterior and mediolateral direction. Joint moments were consistently greater during a snowboard turn, but more fluctuations were observed in skiing. Hence, when comparing joint loading between carved ski and snowboard turns, one should differentiate between forces and moments, including the direction of forces and moments and the turn phase. PMID:25317202

  1. Rapid Prototyping for In Vitro Knee Rig Investigations of Prosthetized Knee Biomechanics: Comparison with Cobalt-Chromium Alloy Implant Material

    PubMed Central

    Schröder, Christian; Steinbrück, Arnd; Müller, Tatjana; Woiczinski, Matthias; Chevalier, Yan; Müller, Peter E.; Jansson, Volkmar

    2015-01-01

    Retropatellar complications after total knee arthroplasty (TKA) such as anterior knee pain and subluxations might be related to altered patellofemoral biomechanics, in particular to trochlear design and femorotibial joint positioning. A method was developed to test femorotibial and patellofemoral joint modifications separately with 3D-rapid prototyped components for in vitro tests, but material differences may further influence results. This pilot study aims at validating the use of prostheses made of photopolymerized rapid prototype material (RPM) by measuring the sliding friction with a ring-on-disc setup as well as knee kinematics and retropatellar pressure on a knee rig. Cobalt-chromium alloy (standard prosthesis material, SPM) prostheses served as validation standard. Friction coefficients between these materials and polytetrafluoroethylene (PTFE) were additionally tested as this latter material is commonly used to protect pressure sensors in experiments. No statistical differences were found between friction coefficients of both materials to PTFE. UHMWPE shows higher friction coefficient at low axial loads for RPM, a difference that disappears at higher load. No measurable statistical differences were found in knee kinematics and retropatellar pressure distribution. This suggests that using polymer prototypes may be a valid alternative to original components for in vitro TKA studies and future investigations on knee biomechanics. PMID:25879019

  2. Load- and skill-related changes in segmental contributions to a weightlifting movement.

    PubMed

    Enoka, R M

    1988-04-01

    An exemplary short duration, high-power, weightlifting event was examined to determine whether the ability to lift heavier loads and whether variations in the level of skill were accompanied by quantitative changes in selected aspects of lower extremity joint power-time histories. Six experienced weightlifters, three skilled and three less skilled, performed the double-knee-bend execution of the pull in Olympic weightlifting, a movement which lasted almost 1 s. Analysis-of-variance statistics were performed on selected peak and average values of power generated by the three skilled subjects as they lifted three loads (69, 77, and 86% of their competition maximum). The results indicated that the skilled subjects lifted heavier loads by increasing the average power, but not the peak power, about the knee and ankle joints. In addition, the changes with load were more subtle than a mere quantitative scaling and also seemed to be associated with a skill element in the form of variation in the duration of the phases of power production and absorption. Similarly, statistical differences (independent t-test) due to skill did not involve changes in the magnitude of power but rather the temporal organization of the movement. Thus, the ability to successfully execute the double-knee-bend movement depends on an athlete's ability to both generate a sufficient magnitude of joint power and to organize the phases of power production and absorption into an appropriate temporal sequence.

  3. Mechanisms of anterior-posterior stability of the knee joint under load-bearing.

    PubMed

    Reynolds, Ryan J; Walker, Peter S; Buza, John

    2017-05-24

    The anterior-posterior (AP) stability of the knee is an important aspect of functional performance. Studies have shown that the stability increases when compressive loads are applied, as indicated by reduced laxity, but the mechanism has not been fully explained. A test rig was designed which applied combinations of AP shear and compressive forces, and measured the AP displacements relative to the neutral position. Five knees were evaluated at compressive loads of 0, 250, 500, and 750N, with the knee at 15° flexion. At each load, three cycles of shear force at ±100N were applied. For the intact knee under load, the posterior tibial displacement was close to zero, due to the upward slope of the anterior medial tibial surface. The soft tissues were then resected in sequence to determine their role in AP laxity. After anterior cruciate ligament (ACL) resection, the anterior tibial displacement increased significantly even under load, highlighting its importance in stability. Meniscal resection further increased displacement but also the vertical displacement increased, implying the meniscus was providing a buffering effect. The PCL had no effect on any of the displacements under load. Plowing cartilage deformation and surface friction were negligible. This work highlighted the particular importance of the upward slope of the anterior medial tibial surface and the ACL to AP knee stability under load. The results are relevant to the design of total knees which reproduce anatomic knee stability behavior. Copyright © 2017. Published by Elsevier Ltd.

  4. The role of knee joint moments and knee impairments on self-reported knee pain during gait in patients with knee osteoarthritis.

    PubMed

    O'Connell, Megan; Farrokhi, Shawn; Fitzgerald, G Kelley

    2016-01-01

    The association between high mechanical knee joint loading during gait with onset and progression of knee osteoarthritis has been extensively studied. However, less attention has been given to risk factors related to increased pain during gait. The purpose of this study was to evaluate knee joint moments and clinical characteristics that may be associated with gait-related knee pain in patients with knee osteoarthritis. Sixty-seven participants with knee osteoarthritis were stratified into three groups of no pain (n=18), mild pain (n=27), or moderate/severe pain (n=22) based on their self-reported symptoms during gait. All participants underwent three-dimensional gait analysis. Quadriceps strength, knee extension range of motion, radiographic knee alignment and self-reported measures of global pain and function were also quantified. The moderate/severe pain group demonstrated worse global pain (P<0.01) and physical function scores (P<0.01) compared to the no pain and the mild pain groups. The moderate/severe pain group also walked with greater knee flexion moments during the midstance phase of gait compared to the no pain group (P=0.02). Additionally, the moderate/severe pain group demonstrated greater varus knee malalignment (P=0.009), which was associated with higher weight acceptance peak knee adduction moments (P=0.003) and worse global pain (P=0.003) and physical function scores (P=0.006). Greater knee flexion moment is present during the midstance phase of gait in patients with knee osteoarthritis and moderate/severe pain during gait. Additionally, greater varus malalignment may be a sign of increased global knee joint dysfunction that can influence many activities of daily living beyond gait. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Increasing Running Step Rate Reduces Patellofemoral Joint Forces

    PubMed Central

    Lenhart, Rachel L.; Thelen, Darryl G.; Wille, Christa M.; Chumanov, Elizabeth S.; Heiderscheit, Bryan C.

    2013-01-01

    Purpose Increasing step rate has been shown to elicit changes in joint kinematics and kinetics during running, and has been suggested as a possible rehabilitation strategy for runners with patellofemoral pain. The purpose of this study was to determine how altering step rate affects internal muscle forces and patellofemoral joint loads, and then to determine what kinematic and kinetic factors best predict changes in joint loading. Methods We recorded whole body kinematics of 30 healthy adults running on an instrumented treadmill at three step rate conditions (90%, 100%, and 110% of preferred step rate). We then used a 3D lower extremity musculoskeletal model to estimate muscle, patellar tendon, and patellofemoral joint forces throughout the running gait cycles. Additionally, linear regression analysis allowed us to ascertain the relative influence of limb posture and external loads on patellofemoral joint force. Results Increasing step rate to 110% of preferred reduced peak patellofemoral joint force by 14%. Peak muscle forces were also altered as a result of the increased step rate with hip, knee and ankle extensor forces, and hip abductor forces all reduced in mid-stance. Compared to the 90% step rate condition, there was a concomitant increase in peak rectus femoris and hamstring loads during early and late swing, respectively, at higher step rates. Peak stance phase knee flexion decreased with increasing step rate, and was found to be the most important predictor of the reduction in patellofemoral joint loading. Conclusion Increasing step rate is an effective strategy to reduce patellofemoral joint forces and could be effective in modulating biomechanical factors that can contribute to patellofemoral pain. PMID:23917470

  6. Effect of intraarticular tramadol administration in the rat model of knee joint inflammation.

    PubMed

    Garlicki, Jarosław; Dorazil-Dudzik, Magdalena; Wordliczek, Jerzy; Przewłocka, Barbara

    2006-01-01

    Local administration of exogenous opioids may cause effective analgesia without adverse symptoms from the central nervous system. Experiments show that peripheral antinociceptive effect of opioids is observed especially in inflammatory pain. The aim of the research was to estimate the effect of tramadol on nociceptive process at the level of peripheral nervous system, after its local administration in the model of knee joint inflammation. Tramadol was administered intraarticulary into the rat knee joint, before the inflammation as a preemptive analgesia and, for comparison, after the intraarticular injection of carrageenan. The research determined the influence of tramadol injection on pain threshold for thermal stimuli, development of inflammatory processes using the measurement of joint edema and motor function following the induction of knee joint inflammation in the rat. Functional assessment of knee joint with inflammation, in terms of rats' mobility and body position as well as joint loading and mobility were studied. The results of the experiments show that local administration of tramadol induces antinociceptive effect. The effect of tramadol, which elicits also a decrease in inflammatory edema, appears not only after its administration after carrageenan when inflammation was already present, but also in the case of its injection prior to carrageenan in the scheme of preemptive analgesia. The results of the described research show that not only morphine but also another opioid, tramadol, widely used in clinical practice, inhibits nociception, edema and functional impairment of the paw after its local application directly to the inflamed knee joint.

  7. Comparative biomechanical analysis of current microprocessor-controlled prosthetic knee joints.

    PubMed

    Bellmann, Malte; Schmalz, Thomas; Blumentritt, Siegmar

    2010-04-01

    To investigate and identify functional differences of 4 microprocessor-controlled prosthetic knee joints (C-Leg, Hybrid Knee [also called Energy Knee], Rheo Knee, Adaptive 2). Tested situations were walking on level ground, on stairs and ramps; additionally, the fall prevention potentials for each design were examined. The measuring technology used included an optoelectronic camera system combined with 2 forceplates as well as a mobile spiroergometric system. The study was conducted in a gait laboratory. Subjects with unilateral transfemoral amputations (N=9; mobility grade, 3-4; age, 22-49y) were tested. Participants were fitted and tested with 4 different microprocessor-controlled knee joints. Static prosthetic alignment, time distance parameters, kinematic and kinetic data and metabolic energy consumption. Compared with the Hybrid Knee and the Adaptive 2, the C-Leg offers clear advantages in the provision of adequate swing phase flexion resistances and terminal extension damping during level walking at various speeds, especially at higher walking speeds. The Rheo Knee provides sufficient terminal extension; however, swing phase flexion resistances seem to be too low. The values for metabolic energy consumption show only slight differences during level walking. The joint resistances generated for descending stairs and ramps relieve the contralateral side to varying degrees. When walking on stairs, safety-relevant technical differences between the investigated joint types can be observed. Designs with adequate internal resistances offer stability advantages when the foot is positioned on the step. Stumble recovery tests reveal that the different knee joint designs vary in their effectiveness in preventing the patient from falling. The patient benefits provided by the investigated electronic prosthetic knee joints differ considerably. The C-Leg appears to offer the amputee greater functional and safety-related advantages than the other tested knee joints. Reduced loading of the contralateral side has been demonstrated during ramp and stair descent. Metabolic energy consumption does not vary significantly between the tested knees. Hence, this parameter seems not to be a suitable criterion for assessing microprocessor-controlled knee components. Copyright 2010 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  8. Gait modification strategies for altering medial knee joint load: a systematic review.

    PubMed

    Simic, Milena; Hinman, Rana S; Wrigley, Tim V; Bennell, Kim L; Hunt, Michael A

    2011-03-01

    To evaluate the effect of gait modification strategies on the external knee adduction moment (KAM), a marker of medial knee joint load; determine potentially adverse effects; assess the methodologic quality; and identify areas of future research. Five electronic databases were searched. Studies evaluating the effects of gait modifications on the KAM in either healthy individuals or those with knee osteoarthritis (OA) were included. Methodologic quality was evaluated by 2 reviewers using the Downs and Black checklist. Twenty-four studies met the inclusion criteria, exploring 14 different gait modifications of varying sample sizes, age groups, and OA classifications. Contralateral cane use, increased step width, medial knee thrust, increased hip internal rotation, weight transfer to the medial foot, and increased lateral trunk lean demonstrated KAM reductions. Tai Chi gait, ipsilateral cane use, Nordic walking poles, and increased knee flexion exhibited increases in the KAM, demonstrating a potential detriment to their use. The effects of reduced stride length, as well as increases and reductions in either toe-out or gait speed, were inconsistent across the studies and gait cycle. This review demonstrates that some gait modifications have the ability to alter knee load. Future research is required to determine the magnitude of modification required to maximize beneficial effects, the best method of training, long-term patient adherence, and if these biomechanical changes can translate into clinically relevant changes in symptoms or disease progression risk. Copyright © 2011 by the American College of Rheumatology.

  9. Stance controlled knee flexion improves stimulation driven walking after spinal cord injury

    PubMed Central

    2013-01-01

    Background Functional neuromuscular stimulation (FNS) restores walking function after paralysis from spinal cord injury via electrical activation of muscles in a coordinated fashion. Combining FNS with a controllable orthosis to create a hybrid neuroprosthesis (HNP) has the potential to extend walking distance and time by mechanically locking the knee joint during stance to allow knee extensor muscle to rest with stimulation turned off. Recent efforts have focused on creating advanced HNPs which couple joint motion (e.g., hip and knee or knee and ankle) to improve joint coordination during swing phase while maintaining a stiff-leg during stance phase. Methods The goal of this study was to investigate the effects of incorporating stance controlled knee flexion during loading response and pre-swing phases on restored gait. Knee control in the HNP was achieved by a specially designed variable impedance knee mechanism (VIKM). One subject with a T7 level spinal cord injury was enrolled and served as his own control in examining two techniques to restore level over-ground walking: FNS-only (which retained a stiff knee during stance) and VIKM-HNP (which allowed controlled knee motion during stance). The stimulation pattern driving the walking motion remained the same for both techniques; the only difference was that knee extensor stimulation was constant during stance with FNS-only and modulated together with the VIKM to control knee motion during stance with VIKM-HNP. Results Stance phase knee angle was more natural during VIKM-HNP gait while knee hyperextension persisted during stiff-legged FNS-only walking. During loading response phase, vertical ground reaction force was less impulsive and instantaneous gait speed was increased with VIKM-HNP, suggesting that knee flexion assisted in weight transfer to the leading limb. Enhanced knee flexion during pre-swing phase also aided flexion during swing, especially when response to stimulation was compromised. Conclusions These results show the potential advantages of incorporating stance controlled knee flexion into a hybrid neuroprosthesis for walking. The addition of such control to FNS driven walking could also enable non-level walking tasks such as uneven terrain, slope navigation and stair descent where controlled knee flexion during weight bearing is critical. PMID:23826711

  10. Influence of Total Knee Arthroplasty on Gait Mechanics of the Replaced and Non-Replaced Limb During Stair Negotiation.

    PubMed

    Standifird, Tyler W; Saxton, Arnold M; Coe, Dawn P; Cates, Harold E; Reinbolt, Jeffrey A; Zhang, Songning

    2016-01-01

    This study compared biomechanics during stair ascent in replaced and non-replaced limbs of total knee arthroplasty (TKA) patients with control limbs of healthy participants. Thirteen TKA patients and fifteen controls performed stair ascent. Replaced and non-replaced knees of TKA patients were less flexed at contact compared to controls. The loading response peak knee extension moment was greater in control and non-replaced knees compared with replaced. The push-off peak knee abduction moment was elevated in replaced limbs compared to controls. Loading and push-off peak hip abduction moments were greater in replaced limbs compared to controls. The push-off peak hip abduction moment was greater in non-replaced limbs compared to controls. Future rehabilitation protocols should consider the replaced knee and also the non-replaced knee and surrounding joints. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Validation of a computational knee joint model using an alignment method for the knee laxity test and computed tomography.

    PubMed

    Kang, Kyoung-Tak; Kim, Sung-Hwan; Son, Juhyun; Lee, Young Han; Koh, Yong-Gon

    2017-01-01

    Computational models have been identified as efficient techniques in the clinical decision-making process. However, computational model was validated using published data in most previous studies, and the kinematic validation of such models still remains a challenge. Recently, studies using medical imaging have provided a more accurate visualization of knee joint kinematics. The purpose of the present study was to perform kinematic validation for the subject-specific computational knee joint model by comparison with subject's medical imaging under identical laxity condition. The laxity test was applied to the anterior-posterior drawer under 90° flexion and the varus-valgus under 20° flexion with a series of stress radiographs, a Telos device, and computed tomography. The loading condition in the computational subject-specific knee joint model was identical to the laxity test condition in the medical image. Our computational model showed knee laxity kinematic trends that were consistent with the computed tomography images, except for negligible differences because of the indirect application of the subject's in vivo material properties. Medical imaging based on computed tomography with the laxity test allowed us to measure not only the precise translation but also the rotation of the knee joint. This methodology will be beneficial in the validation of laxity tests for subject- or patient-specific computational models.

  12. Ankle Dorsiflexion Displacement During Landing is Associated With Initial Contact Kinematics but not Joint Displacement.

    PubMed

    Begalle, Rebecca L; Walsh, Meghan C; McGrath, Melanie L; Boling, Michelle C; Blackburn, J Troy; Padua, Darin A

    2015-08-01

    The ankle, knee, and hip joints work together in the sagittal plane to absorb landing forces. Reduced sagittal plane motion at the ankle may alter landing strategies at the knee and hip, potentially increasing injury risk; however, no studies have examined the kinematic relationships between the joints during jump landings. Healthy adults (N = 30; 15 male, 15 female) performed jump landings onto a force plate while three-dimensional kinematic data were collected. Joint displacement values were calculated during the loading phase as the difference between peak and initial contact angles. No relationship existed between ankle dorsiflexion displacement during landing and three-dimensional knee and hip displacements. However, less ankle dorsiflexion displacement was associated with landing at initial ground contact with larger hip flexion, hip internal rotation, knee flexion, knee varus, and smaller plantar flexion angles. Findings of the current study suggest that restrictions in ankle motion during landing may contribute to contacting the ground in a more flexed position but continuing through little additional motion to absorb the landing. Transverse plane hip and frontal plane knee positioning may also occur, which are known to increase the risk of lower extremity injury.

  13. Characterizing Knee Loading Asymmetry in Individuals Following Anterior Cruciate Ligament Reconstruction Using Inertial Sensors

    PubMed Central

    Sigward, Susan M.; Chan, Ming-Sheng M.; Lin, Paige E.

    2016-01-01

    Limitations in the ability to identify knee extensor loading deficits during gait in individuals following anterior cruciate ligament reconstruction (ACLr) may underlie their persistence. A recent study suggested that shank angular velocity, directly output from inertial sensors, differed during gait between individuals post-ACLr and controls. However, it is not clear if this kinematic variable relates to knee moments calculated using joint kinematics and ground reaction forces. Heel rocker mechanics during loading response of gait, characterized by rapid shank rotation, require knee extensor control. Measures of shank angular velocity may be reflective of knee moments. This study investigated the relationship between shank angular velocity and knee extensor moment during gait in individuals (n=19) 96.7±16.8 days post-ACLr. Gait was assessed concurrently using inertial sensors and a marker-based motion system with force platforms. Peak angular velocity and knee extensor moment were strongly correlated (r=0.75, p<0.001) and between limb ratios of angular velocity predicted between limb ratios of extensor moment (r2=0.57 ,p<0.001) in the absence of between limb differences in spatiotemporal gait parameters. The strength of these relationships indicate that shank kinematic data offer meaningful information regarding knee loading and provide a potential alternative to full motion analysis systems for identification of altered knee loading following ACLr PMID:27395452

  14. Design and evaluation of a quasi-passive knee exoskeleton for investigation of motor adaptation in lower extremity joints.

    PubMed

    Shamaei, Kamran; Cenciarini, Massimo; Adams, Albert A; Gregorczyk, Karen N; Schiffman, Jeffrey M; Dollar, Aaron M

    2014-06-01

    In this study, we describe the mechanical design and control scheme of a quasi-passive knee exoskeleton intended to investigate the biomechanical behavior of the knee joint during interaction with externally applied impedances. As the human knee behaves much like a linear spring during the stance phase of normal walking gait, the exoskeleton implements a spring across the knee in the weight acceptance (WA) phase of the gait while allowing free motion throughout the rest of the gait cycle, accomplished via an electromechanical clutch. The stiffness of the device is able to be varied by swapping springs, and the timing of engagement/disengagement changed to accommodate different loading profiles. After describing the design and control, we validate the mechanical performance and reliability of the exoskeleton through cyclic testing on a mechanical knee simulator. We then describe a preliminary experiment on three healthy adults to evaluate the functionality of the device on both left and right legs. The kinetic and kinematic analyses of these subjects show that the exoskeleton assistance can partially/fully replace the function of the knee joint and obtain nearly invariant moment and angle profiles for the hip and ankle joints, and the overall knee joint and exoskeleton complex under the applied moments of the exoskeleton versus the control condition, implying that the subjects undergo a considerable amount of motor adaptation in their lower extremities to the exoskeletal impedances, and encouraging more in-depth future experiments with the device.

  15. Knee Joint Loading during Gait in Healthy Controls and Individuals with Knee Osteoarthritis

    PubMed Central

    Kumar, Deepak; Manal, Kurt T.; Rudolph, Katherine S.

    2013-01-01

    Objective People with knee osteoarthritis (OA) are thought to walk with high loads at the knee which are yet to be quantfied using modeling techniques that account for subject specific EMG patterns, kinematics and kinetics. The objective was to estimate medial and lateral loading for people with knee OA and controls using an approach that is sensitive to subject specific muscle activation patterns. Methods 16 OA and 12 control (C) subjects walked while kinematic, kinetic and EMG data were collected. Muscle forces were calculated using an EMG-Driven model and loading was calculated by balancing the external moments with internal muscle and contact forces Results OA subjects walked slower and had greater laxity, static and dynamic varus alignment, less flexion and greater knee adduction moment (KAM). Loading (normalized to body weight) was no different between the groups but OA subjects had greater absolute medial load than controls and maintained a greater %total load on the medial compartment. These patterns were associated with body mass, sagittal and frontal plane moments, static alignment and close to signficance for dynamic alignment. Lateral compartment unloading during mid-late stance was observed in 50% of OA subjects. Conclusions Loading for control subjects was similar to data from instrumented prostheses. Knee OA subjects had high medial contact loads in early stance and half of the OA cohort demonstared lateral compartment lift-off. Results suggest that interventions aimed at reducing body weight and dynamic malalignment might be effective in reducing medial compartment loading and establishing normal medio-lateral load sharing patterns. PMID:23182814

  16. Knee joint laxity does not moderate the relationship between quadriceps strength and physical function in knee osteoarthritis patients: A cross-sectional study.

    PubMed

    Altubasi, Ibrahim M

    2018-06-07

    Knee osteoarthritis is a common and a disabling musculoskeletal disorder. Patients with knee osteoarthritis have activity limitations which are linked to the strength of the quadriceps muscle. Previous research reported that the relationship between quadriceps muscle strength and physical function is moderated by the level of knee joint frontal plane laxity. The purpose of the current study is to reexamine the moderation effect of the knee joint laxity as measured by stress radiographs on the relationship between quadriceps muscle strength and physical function. One-hundred and sixty osteoarthritis patients participated in this cross-sectional study. Isometric quadriceps muscle strength was measured using an isokinetic dynamometer. Self-rated and performance-based physical function were measured using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) physical function subscale and Get Up and Go test, respectively. Stress radiographs which were taken while applying varus and valgus loads to knee using the TELOS device. Knee joint laxity was determined by measuring the distance between joint surfaces on the medial and lateral sides. Hierarchical multiple regression models were constructed to study the moderation effect of laxity on the strength function relationship. Two regression models were constructed for self-rated and performance-based function. After controlling for demographics, strength contributed significantly in the models. The addition of laxity and laxity-strength interaction did not add significant contributions in the regression models. Frontal plane knee joint laxity measured by stress radiographs does not moderate the relationship between quadriceps muscle strength and physical function in patients with osteoarthritis. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Knee contact forces and lower extremity support moments during running in young individuals post-partial meniscectomy.

    PubMed

    Willy, R W; Bigelow, M A; Kolesar, A; Willson, J D; Thomas, J S

    2017-01-01

    While partial meniscectomy results in a compromised tibiofemoral joint, little is known regarding tibiofemoral joint loading during running in individuals who are post-partial meniscectomy. It was hypothesized that individuals post-partial meniscectomy would run with a greater hip support moment, yielding reduced peak knee extension moments and reduced tibiofemoral joint contact forces. 3-D Treadmill running mechanics were evaluated in 23 athletic individuals post-partial meniscectomy (37.5 ± 19.0 months post-partial meniscectomy) and 23 matched controls. Bilateral hip, knee and ankle contributions to the total support moment and the peak knee extension moment were calculated. A musculoskeletal model estimated peak and impulse tibiofemoral joint contact forces. Knee function was quantified with the Knee injury and Osteoarthritis Outcome Score (KOOS). During running, the partial meniscectomy group had a greater hip support moment (p = 0.002) and a reduced knee support moment (p < 0.001) relative to the total support moment. This movement pattern was associated with a 14.5 % reduction (p = 0.019) in the peak knee extension moment. Despite these differences, there were no significant group differences in peak or impulse tibiofemoral joint contact forces. Lower KOOS Quality of Life scores were associated with greater hip support moment (p = 0.004, r = -0.58), reduced knee support moment (p = 0.006, r = 0.55) and reduced peak knee extension moment (p = 0.01, r = 0.52). Disordered running mechanics are present long term post-partial meniscectomy. A coordination strategy that shifts a proportion of the total support moment away from the knee to the hip reduces the peak knee extension moment, but does not equate to reduced tibiofemoral joint contact forces during running in individuals post-partial meniscectomy. III.

  18. Bracing of the Reconstructed and Osteoarthritic Knee during High Dynamic Load Tasks.

    PubMed

    Hart, Harvi F; Crossley, Kay M; Collins, Natalie J; Ackland, David C

    2017-06-01

    Lateral compartment osteoarthritis accompanied by abnormal knee biomechanics is frequently reported in individuals with knee osteoarthritis after anterior cruciate ligament reconstruction (ACLR). The aim of this study was to evaluate changes in knee biomechanics produced by an adjusted and unadjusted varus knee brace during high dynamic loading activities in individuals with lateral knee osteoarthritis after ACLR and valgus malalignment. Nineteen participants who had undergone ACLR 5 to 20 yr previously and had symptomatic and radiographic lateral knee osteoarthritis with valgus malalignment were assessed. Quantitative motion analysis experiments were conducted during hopping, stair ascent, and descent under three test conditions: (i) no brace, (ii) unadjusted brace with sagittal plane support and neutral frontal plane alignment, and (iii) adjusted brace with sagittal plane support and varus realignment (valgus to neutral). Sagittal, frontal, and transverse plane knee kinematics, external joint moment, and angular impulse data were calculated. Relative to an unbraced knee, braced conditions significantly increased knee flexion and adduction angles during hopping (P = 0.003 and P = 0.005; respectively), stair ascent (P = 0.003 and P < 0.001, respectively), and descent (P = 0.009 and P < 0.001, respectively). In addition, the brace conditions increased knee flexion (P < 0.001) and adduction (P = 0.001) angular impulses and knee stiffness (P < 0.001) during hopping, as well as increased knee adduction moments during stair ascent (P = 0.008) and flexion moments during stair descent (P = 0.006). There were no significant differences between the adjusted and the unadjusted brace conditions (P > 0.05). A knee brace, with or without varus alignment, can modulate knee kinematics and external joint moments during hopping, stairs ascent, and descent in individuals with predominant lateral knee osteoarthritis after ACLR. Longer-term use of a brace may have implications in slowing osteoarthritis progression.

  19. Effects of medial meniscal posterior horn avulsion and repair on meniscal displacement.

    PubMed

    Hein, Christopher N; Deperio, Jennifer Gurske; Ehrensberger, Mark T; Marzo, John M

    2011-06-01

    Medial meniscal posterior root avulsion (MMRA) leads to deleterious alteration of medial joint compartment loading profiles and increased risk of medial degenerative changes. Surgical repair restores more normal biomechanics to the knee. Our hypothesis is that MMRA will cause medial meniscal (MM) extrusion and gap formation between the root attachment site and MM. Meniscal root repair will restore the ability of the meniscus to resist extrusion, and reduce gap formation at the defect. Seven fresh frozen human cadaveric knees were dissected and mechanically loaded using a servo-hydraulic load frame (MTS ®) with 0 and 1800 N. The knees were tested under three conditions: native, avulsed, and repaired. Four measurements were obtained: meniscal displacement anteriorly, medially, posteriorly, and gap distance between the root attachment site and MM after transection and repair. The medial displacement of the avulsed MM (3.28 mm) was significantly greater (p < 0.001) than the native knee (1.60mm) and repaired knee (1.46 mm). Gap formation is significantly larger in the avulsed compared to repaired state at 0 (p < 0.02) and 1800N (p < 0.02) and also larger with loading in both avulsed (p < 0.05) and repaired (p < 0.02) conditions. Therefore, MMRA results in MM extrusion from the joint and gap formation between the MM root and the MM. Subsequent surgical repair reduces meniscal displacement and gap formation at the defect. Copyright © 2010 Elsevier B.V. All rights reserved.

  20. Multibody dynamic simulation of knee contact mechanics

    PubMed Central

    Bei, Yanhong; Fregly, Benjamin J.

    2006-01-01

    Multibody dynamic musculoskeletal models capable of predicting muscle forces and joint contact pressures simultaneously would be valuable for studying clinical issues related to knee joint degeneration and restoration. Current three-dimensional multi-body knee models are either quasi-static with deformable contact or dynamic with rigid contact. This study proposes a computationally efficient methodology for combining multibody dynamic simulation methods with a deformable contact knee model. The methodology requires preparation of the articular surface geometry, development of efficient methods to calculate distances between contact surfaces, implementation of an efficient contact solver that accounts for the unique characteristics of human joints, and specification of an application programming interface for integration with any multibody dynamic simulation environment. The current implementation accommodates natural or artificial tibiofemoral joint models, small or large strain contact models, and linear or nonlinear material models. Applications are presented for static analysis (via dynamic simulation) of a natural knee model created from MRI and CT data and dynamic simulation of an artificial knee model produced from manufacturer’s CAD data. Small and large strain natural knee static analyses required 1 min of CPU time and predicted similar contact conditions except for peak pressure, which was higher for the large strain model. Linear and nonlinear artificial knee dynamic simulations required 10 min of CPU time and predicted similar contact force and torque but different contact pressures, which were lower for the nonlinear model due to increased contact area. This methodology provides an important step toward the realization of dynamic musculoskeletal models that can predict in vivo knee joint motion and loading simultaneously. PMID:15564115

  1. A new distraction arthroplasty device using magnetic force; a cadaveric study.

    PubMed

    Kamei, Goki; Ochi, Mitsuo; Okuhara, Atsushi; Fujimiya, Mineko; Deie, Masataka; Adachi, Nobuo; Nakamae, Atsuo; Nakasa, Tomoyuki; Ohkawa, Shingo; Takazawa, Kobun; Eguchi, Akio; Katou, Tomohiro; Takada, Tsuyoshi; Usman, Muhammad Andry

    2013-04-01

    It is difficult for an articular cartilage injury to repair spontaneously. There are many procedures for treating cartilage injury, however there is no standard procedure for middle-aged patients who have diffuse knee osteoarthritis, especially of the lateral compartment. Therefore, Ochi developed a new distraction device that uses magnetic power to enlarge a joint space and promote cartilage regeneration with microfracture. The purpose of this study is to evaluate this new distraction arthroplasty system by using the cadaveric knee. This study used ten knees from six cadavers that were embalmed by Thiel's methods. The medial and lateral joint space was measured by AP radiographic view before and after distraction, and after weight-bearing to evaluate the joint distraction. The contact pressure of the medial and lateral compartments at the knee extension position by using a prescale film system was measured before and after weight-bearing with a 15 or 30-kg weight-bearing load to evaluate the effectiveness of this device. The lateral joint space significantly increased from the pre-distraction to the post-distraction; however, it did not change significantly between post-distraction and post-weight-bearing. With a 15 or 30-kg weight-bearing load, the contact pressure of the lateral compartment significantly decreased from the pre-distraction to the post-distraction. The most important advantage of this device is that it maintains a continuous distraction tension and enables almost the full range of motion of the knee. We believe that joint distraction by using magnetic force can be a promising option for cartilage injury in middle-aged patients. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Mediolateral force distribution at the knee joint shifts across activities and is driven by tibiofemoral alignment.

    PubMed

    Kutzner, I; Bender, A; Dymke, J; Duda, G; von Roth, P; Bergmann, G

    2017-06-01

    Tibiofemoral alignment is important to determine the rate of progression of osteoarthritis and implant survival after total knee arthroplasty (TKA). Normally, surgeons aim for neutral tibiofemoral alignment following TKA, but this has been questioned in recent years. The aim of this study was to evaluate whether varus or valgus alignment indeed leads to increased medial or lateral tibiofemoral forces during static and dynamic weight-bearing activities. Tibiofemoral contact forces and moments were measured in nine patients with instrumented knee implants. Medial force ratios were analysed during nine daily activities, including activities with single-limb support (e.g. walking) and double-limb support (e.g. knee bend). Hip-knee-ankle angles in the frontal plane were analysed using full-leg coronal radiographs. The medial force ratio strongly correlated with the tibiofemoral alignment in the static condition of one-legged stance (R² = 0.88) and dynamic single-limb loading (R² = 0.59) with varus malalignment leading to increased medial force ratios of up to 88%. In contrast, the correlation between leg alignment and magnitude of medial compartment force was much less pronounced. A lateral shift of force occurred during activities with double-limb support and higher knee flexion angles. The medial force ratio depends on both the tibiofemoral alignment and the nature of the activity involved. It cannot be generalised to a single value. Higher medial ratios during single-limb loading are associated with varus malalignment in TKA. The current trend towards a 'constitutional varus' after joint replacement, in terms of overall tibiofemoral alignment, should be considered carefully with respect to the increased medial force ratio. Cite this article: Bone Joint J 2017;99-B:779-87. ©2017 The British Editorial Society of Bone & Joint Surgery.

  3. Joint Loads and Cartilage Stress in Intact Joints of Military Transtibial Amputees: Enhancing Quality of Life

    DTIC Science & Technology

    2017-04-01

    crosstalk); analysis of tested subjects underway. 4) Developed analytical methods to obtain knee joint loads using EMG-driven inverse dynamics; analysis of...13/2018. Completion %: 40. Task 1.3: EMG-driven inverse dynamic (ID) analyses with OpenSim for amputee and control group subjects. Target date: 1...predicted by EMG-driven inverse dynamics. Two-three conference papers are being prepared for submission in February 2017. Other achievements. None

  4. Screw-Home Movement of the Tibiofemoral Joint during Normal Gait: Three-Dimensional Analysis

    PubMed Central

    Kim, Ha Yong; Yang, Dae Suk; Jeung, Sang Wook; Choi, Han Gyeol; Choy, Won Sik

    2015-01-01

    Background The purpose of this study was to evaluate the screw-home movement at the tibiofemoral joint during normal gait by utilizing the 3-dimensional motion capture technique. Methods Fifteen young males and fifteen young females (total 60 knee joints) who had no history of musculoskeletal disease or a particular gait problem were included in this study. Two more markers were attached to the subject in addition to the Helen-Hayes marker set. Thus, two virtual planes, femoral coronal plane (Pf) and tibial coronal plane (Pt), were created by Skeletal Builder software. This study measured the 3-dimensional knee joint movement in the sagittal, coronal, and transverse planes of these two virtual planes (Pf and Pt) during normal gait. Results With respect to kinematics and kinetics, both males and females showed normal adult gait patterns, and the mean difference in the temporal gait parameters was not statistically significant (p > 0.05). In the transverse plane, the screw-home movement occurred as expected during the pre-swing phase and the late-swing phase at an angle of about 17°. However, the tibia rotated externally with respect to the femur, rather than internally, while the knee joint started to flex during the loading response (paradoxical screw-home movement), and the angle was 6°. Conclusions Paradoxical screw-home movement may be an important mechanism that provides stability to the knee joint during the remaining stance phase. Obtaining the kinematic values of the knee joint during gait can be useful in diagnosing and treating the pathological knee joints. PMID:26330951

  5. Screw-Home Movement of the Tibiofemoral Joint during Normal Gait: Three-Dimensional Analysis.

    PubMed

    Kim, Ha Yong; Kim, Kap Jung; Yang, Dae Suk; Jeung, Sang Wook; Choi, Han Gyeol; Choy, Won Sik

    2015-09-01

    The purpose of this study was to evaluate the screw-home movement at the tibiofemoral joint during normal gait by utilizing the 3-dimensional motion capture technique. Fifteen young males and fifteen young females (total 60 knee joints) who had no history of musculoskeletal disease or a particular gait problem were included in this study. Two more markers were attached to the subject in addition to the Helen-Hayes marker set. Thus, two virtual planes, femoral coronal plane (P f ) and tibial coronal plane (P t ), were created by Skeletal Builder software. This study measured the 3-dimensional knee joint movement in the sagittal, coronal, and transverse planes of these two virtual planes (P f and P t ) during normal gait. With respect to kinematics and kinetics, both males and females showed normal adult gait patterns, and the mean difference in the temporal gait parameters was not statistically significant (p > 0.05). In the transverse plane, the screw-home movement occurred as expected during the pre-swing phase and the late-swing phase at an angle of about 17°. However, the tibia rotated externally with respect to the femur, rather than internally, while the knee joint started to flex during the loading response (paradoxical screw-home movement), and the angle was 6°. Paradoxical screw-home movement may be an important mechanism that provides stability to the knee joint during the remaining stance phase. Obtaining the kinematic values of the knee joint during gait can be useful in diagnosing and treating the pathological knee joints.

  6. Effects of high-heeled shoes and asymmetrical load carrying on lower-extremity kinematics during walking in young women.

    PubMed

    Lee, Soul; Li, Jing Xian

    2014-01-01

    Asymmetrical load carrying and wearing high-heeled shoes are very common. Biomechanics studies on the combined effects of high-heeled shoe wearing and asymmetrical load carrying are lacking. We sought to identify changes in lower-extremity joint kinematics associated with the effect of shoes and asymmetrical load carrying during walking. Fifteen healthy young women (mean ± SD: age, 24.67 ± 3.54 years; body weight, 54.96 ± 6.67 kg; and height, 162.2 ± 3.91 cm) who habitually wore high-heeled shoes participated in the study. They were asked to walk under nine combined conditions of three heights of shoe heels (0, 3, and 9 cm) and three carried loads (0%, 5%, and 10% of body weight). Temporospatial parameters and maximal joint angles in the sagittal and frontal planes of the hip, knee, and ankle on both limbs were studied. It was found that high-heeled shoe wearing and asymmetrical load carrying altered temporospatial parameters and joint kinematics. With increased heel height and load weight, cadence decreased and stride length increased. The knee flexion angle increased with an increase in heel height, and the load served only to exacerbate the changes. Changes in the hip angle were mostly caused by asymmetrical load carrying, whereas angle changes in the ankle were mostly caused by an increase in heel height. This study demonstrated that when high-heeled shoe wearing and asymmetrical load carrying are combined, changes at each joint are much greater than with high-heeled shoe wearing or load carrying alone.

  7. The influence of knee alignment on lower extremity kinetics during squats.

    PubMed

    Slater, Lindsay V; Hart, Joseph M

    2016-12-01

    The squat is an assessment of lower extremity alignment during movement, however there is little information regarding altered joint kinetics during poorly performed squats. The purpose of this study was to examine changes in joint kinetics and power from altered knee alignment during a squat. Thirty participants completed squats while displacing the knee medially, anteriorly, and with neutral alignment (control). Sagittal and frontal plane torques at the ankle, knee, and hip were altered in the descending and ascending phase of the squat in both the medial and anterior malaligned squat compared to the control squat. Ankle and trunk power increased and hip power decreased in the medial malaligned squat compared to the control squat. Ankle, knee, and trunk power increased and hip power decreased in the anterior malaligned squat compared to the control squat. Changes in joint torques and power during malaligned squats suggest that altered knee alignment increases ankle and trunk involvement to execute the movement. Increased anterior knee excursion during squatting may also lead to persistent altered loading of the ankle and knee. Sports medicine professionals using the squat for quadriceps strengthening must consider knee alignment to reduce ankle and trunk involvement during the movement. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Computational Modelling of Patella Femoral Kinematics During Gait Cycle and Experimental Validation

    NASA Astrophysics Data System (ADS)

    Maiti, Raman

    2016-06-01

    The effect of loading and boundary conditions on patellar mechanics is significant due to the complications arising in patella femoral joints during total knee replacements. To understand the patellar mechanics with respect to loading and motion, a computational model representing the patella femoral joint was developed and validated against experimental results. The computational model was created in IDEAS NX and simulated in MSC ADAMS/VIEW software. The results obtained in the form of internal external rotations and anterior posterior displacements for a new and experimentally simulated specimen for patella femoral joint under standard gait condition were compared with experimental measurements performed on the Leeds ProSim knee simulator. A good overall agreement between the computational prediction and the experimental data was obtained for patella femoral kinematics. Good agreement between the model and the past studies was observed when the ligament load was removed and the medial lateral displacement was constrained. The model is sensitive to ±5 % change in kinematics, frictional, force and stiffness coefficients and insensitive to time step.

  9. Computational Modelling of Patella Femoral Kinematics During Gait Cycle and Experimental Validation

    NASA Astrophysics Data System (ADS)

    Maiti, Raman

    2018-06-01

    The effect of loading and boundary conditions on patellar mechanics is significant due to the complications arising in patella femoral joints during total knee replacements. To understand the patellar mechanics with respect to loading and motion, a computational model representing the patella femoral joint was developed and validated against experimental results. The computational model was created in IDEAS NX and simulated in MSC ADAMS/VIEW software. The results obtained in the form of internal external rotations and anterior posterior displacements for a new and experimentally simulated specimen for patella femoral joint under standard gait condition were compared with experimental measurements performed on the Leeds ProSim knee simulator. A good overall agreement between the computational prediction and the experimental data was obtained for patella femoral kinematics. Good agreement between the model and the past studies was observed when the ligament load was removed and the medial lateral displacement was constrained. The model is sensitive to ±5 % change in kinematics, frictional, force and stiffness coefficients and insensitive to time step.

  10. Primary and coupled motions of the native knee in response to applied varus and valgus load.

    PubMed

    Gladnick, Brian P; Boorman-Padgett, James; Stone, Kyle; Kent, Robert N; Cross, Michael B; Mayman, David J; Pearle, Andrew D; Imhauser, Carl W

    2016-06-01

    Knowledge of the complex kinematics of the native knee is a prerequisite for a successful reconstructive procedure. The aim of this study is to describe the primary and coupled motions of the native knee throughout the range of knee flexion, in response to applied varus and valgus loads. Twenty fresh-frozen cadaver knees were affixed to a six degree of freedom robotic arm with a universal force-moment sensor, and loaded with a 4Nm moment in varus and valgus at 0, 15, 30, 45, and 90° of knee flexion. The resulting tibiofemoral angulation, displacement, and rotation were recorded. For each parameter investigated, the knee joint demonstrated more laxity at higher flexion angles. Varus angulation increased progressively from zero (2.0° varus) to 90 (5.2° varus) degrees of knee flexion (p<0.001). Valgus angulation also increased progressively, from zero (1.5° valgus) to 90 (3.9° valgus) degrees of knee flexion (p<0.001). At all flexion angles, the magnitude of tibiofemoral angle deviation was larger with varus than with valgus loading (p<0.05). We conclude that the native knee exhibits small increases in coronal plane laxity as the flexion angle increases, and that the knee has generally more laxity under varus load than with valgus load throughout the Range of Motion (ROM). Larger differences in laxity of more than 2 to 3°, or peak laxity specifically during the range of mid-flexion, were not found in our cadaver model and are not likely to represent normal coronal plane kinematics. Level V, biomechanical cadaveric study. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Lateral Wedge Insoles for Reducing Biomechanical Risk Factors for Medial Knee Osteoarthritis Progression: A Systematic Review and Meta-Analysis.

    PubMed

    Arnold, John B; Wong, Daniel X; Jones, Richard K; Hill, Catherine L; Thewlis, Dominic

    2016-07-01

    Lateral wedge insoles are intended to reduce biomechanical risk factors of medial knee osteoarthritis (OA) progression, such as increased knee joint load; however, there has been no definitive consensus on this topic. The aim of this systematic review and meta-analysis was to establish the within-subject effects of lateral wedge insoles on knee joint load in people with medial knee OA during walking. Six databases were searched from inception until February 13, 2015. Included studies reported on the immediate biomechanical effects of lateral wedge insoles during walking in people with medial knee OA. Primary outcomes of interest relating to the biomechanical risk of disease progression were the first and second peak external knee adduction moment (EKAM) and knee adduction angular impulse (KAAI). Eligible studies were pooled using random-effects meta-analysis. Eighteen studies were included with a total of 534 participants. Lateral wedge insoles resulted in a small but statistically significant reduction in the first peak EKAM (standardized mean difference [SMD] -0.19; 95% confidence interval [95% CI] -0.23, -0.15) and second peak EKAM (SMD -0.25; 95% CI -0.32, -0.19) with a low level of heterogeneity (I(2)  = 5% and 30%, respectively). There was a favorable but small reduction in the KAAI with lateral wedge insoles (SMD -0.14; 95% CI -0.21, -0.07, I(2)  = 31%). Risk of methodologic bias scores (quality index) ranged from 8 to 13 out of 16. Lateral wedge insoles cause small reductions in the EKAM and KAAI during walking in people with medial knee OA. Current evidence demonstrates that lateral wedge insoles appear ineffective at attenuating structural changes in people with medial knee OA as a whole and may be better suited to targeted use in biomechanical phenotypes associated with larger reductions in knee load. © 2016, American College of Rheumatology.

  12. Correction of static axial alignment in children with knee varus or valgus deformities through guided growth: Does it also correct dynamic frontal plane moments during walking?

    PubMed

    Böhm, Harald; Stief, Felix; Sander, Klaus; Hösl, Matthias; Döderlein, Leonhard

    2015-09-01

    Malaligned knees are predisposed to the development and progression of unicompartmental degenerations because of the excessive load placed on one side of the knee. Therefore, guided growth in skeletally immature patients is recommended. Indication for correction of varus/valgus deformities are based on static weight bearing radiographs. However, the dynamic knee abduction moment during walking showed only a weak correlation to malalignment determined by static radiographs. Therefore, the aim of the study was to measure the effects of guided growth on the normalization of frontal plane knee joint moments during walking. 15 legs of 8 patients (11-15 years) with idiopathic axial varus or valgus malalignment were analyzed. 16 typically developed peers served as controls. Instrumented gait analysis and clinical assessment were performed the day before implantation and explantation of eight-plates. Correlation between static mechanical tibiofemoral axis angle (MAA) and dynamic frontal plane knee joint moments and their change by guided growth were performed. The changes in dynamic knee moment in the frontal plane following guided growth showed high and significant correlation to the changes in static MAA (R=0.97, p<0.001). Contrary to the correlation of the changes, there was no correlation between static and dynamic measures in both sessions. In consequence two patients that had a natural knee moment before treatment showed a more pathological one after treatment. In conclusion, the changes in the dynamic load situation during walking can be predicted from the changes in static alignment. If pre-surgical gait analysis reveals a natural load situation, despite a static varus or valgus deformity, the intervention must be critically discussed. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Isokinetic and isometric strength-endurance after 6 hours of immersion and 6 degrees head-down tilt in men

    NASA Technical Reports Server (NTRS)

    Shaffer-Bailey, M.; Greenleaf, J. E.; Hutchinson, T. M.

    1996-01-01

    PURPOSE: To determine weight (water) loss levels for onset of muscular strength and endurance changes during deconditioning. METHODS: Seven men (27-40 yr) performed maximal shoulder-, knee-, and ankle-joint isometric (0 degree.s(-1) load) and isokinetic (60 degrees, 120 degrees, 180 degrees.s(-1) velocity) exercise tests during ambulatory control (AC), after 6 h of 6 degrees head-down tilt (HDT; dry-bulb temp. = 23.2 +/- SD 0.6 degrees C, relative humidity = 31.1+/- 11.1%) and after 6 h of 80 degrees foot-down head-out water immersion (WI; water temp. = 35.0 +/- SD 0.1 degree C) treatments. RESULTS: Weight (water) loss after HDT (1.10 +/- SE 0.14 kg, 1.4 +/- 0.2% body wt) and WI (1.54+/- 0.19 kg, 2.0 +/- 0.2% body wt) were not different, but urinary excretion with WI (1,354 +/- 142 ml.6 h(-1)) was 28% greater (p < 0.05) than that of 975 +/- 139 ml.6 h(-1) with HDT. Muscular endurance (total work; maximal flexion-extension of the non-dominant knee at 180 degrees.s(-1) for 30 s) was not different between AC and the WI or HDT treatments. Shoulder-, knee-, and ankle-joint strength was unchanged except for three knee-joint peak torques: AC torque (120 degrees.s(-1), 285 +/- 20 Nm) decreased to 268 +/- 21 Nm (delta = -6%, p < 0.05) with WI; and AC torques (180 degrees.s(-1), 260 +/- 19 Nm) decreased to 236 +/- 15 Nm (delta = -9%, p < 0.01) with HDT, and to 235 +/- 19 Nm (delta = -10%, p < 0.01) with WI. CONCLUSION: Thus, the total body hypohydration threshold level for shoulder- and ankle-joint strength and endurance decrements is more than 2% body weight (water) loss, while significant reduction in knee-joint muscular strength-endurance occurred only at moderate (120 degrees.s(-1) and lighter (180 degrees.s(-1)) loads with body weight loss of 1.4-2.0% following WI or HDT, respectively. These weight (water) losses and knee-joint strength decrements are somewhat less than the mean weight loss of 2.6% and knee-joint strength decrements of 6-20% of American astronauts after Skylab flights to 84 d.

  14. Physiological joint line total knee arthroplasty designs are especially sensitive to rotational placement - A finite element analysis.

    PubMed

    Moewis, Philippe; Checa, Sara; Kutzner, Ines; Hommel, Hagen; Duda, Georg N

    2018-01-01

    Mechanical and kinematical aligning techniques are the usual positioning methods during total knee arthroplasty. However, alteration of the physiological joint line and unbalanced medio-lateral load distribution are considered disadvantages in the mechanical and kinematical techniques, respectively. The aim of this study was to analyse the influence of the joint line on the strain and stress distributions in an implanted knee and their sensitivity to rotational mal-alignment. Finite element calculations were conducted to analyse the stresses in the PE-Inlay and the mechanical strains at the bone side of the tibia component-tibia bone interface during normal positioning of the components and internal and external mal-rotation of the tibial component. Two designs were included, a horizontal and a physiological implant. The loading conditions are based on internal knee joint loads during walking. A medialization of the stresses on the PE-Inlay was observed in the physiological implant in a normal position, accompanied by higher stresses in the mal-rotated positions. Within the tibia component-tibia bone interface, similar strain distributions were observed in both implant geometries in the normal position. However, a medialization of the strains was observed in the physiological implant in both mal-rotated conditions with greater bone volume affected by higher strains. Although evident changes due to mal-rotation were observed, the stresses do not suggest a local plastic deformation of the PE-Inlay. The strains values within most of the tibia component-tibia bone interface were in the physiological strain zone and no significant bone changes would be expected. The physiological cut on the articular aspect showed no detrimental effect compared to the horizontal implant.

  15. Fatigue injury risk in anterior cruciate ligament of target side knee during golf swing.

    PubMed

    Purevsuren, Tserenchimed; Kwon, Moon Seok; Park, Won Man; Kim, Kyungsoo; Jang, Seung Ho; Lim, Young-Tae; Kim, Yoon Hyuk

    2017-02-28

    A golf-related ACL injury can be linked with excessive golf play or practice because such over-use by repetitive golf swing motions can increase damage accumulation to the ACL bundles. In this study, joint angular rotations, forces, and moments, as well as the forces and strains on the ACL of the target-side knee joint, were investigated for ten professional golfers using the multi-body lower extremity model. The fatigue life of the ACL was also predicted by assuming the estimated ACL force as a cyclic load. The ACL force and strain reached their maximum values within a short time just after ball-impact in the follow-through phase. The smaller knee flexion, higher internal tibial rotation, increase of the joint compressive force and knee abduction moment in the follow-through phase were shown as to lead an increased ACL loading. The number of cycles to fatigue failure (fatigue life) in the ACL might be several thousands. It is suggested that the excessive training or practice of swing motion without enough rest may be one of factors to lead to damage or injury in the ACL by the fatigue failure. The present technology can provide fundamental information to understand and prevent the ACL injury for golf players. Copyright © 2017. Published by Elsevier Ltd.

  16. A comparison of muscle stiffness and musculoarticular stiffness of the knee joint in young athletic males and females.

    PubMed

    Wang, Dan; De Vito, Giuseppe; Ditroilo, Massimiliano; Fong, Daniel T P; Delahunt, Eamonn

    2015-06-01

    The objective of this study was to investigate the gender-specific differences in peak torque (PT), muscle stiffness (MS) and musculoarticular stiffness (MAS) of the knee joints in a young active population. Twenty-two male and twenty-two female recreational athletes participated. PT of the knee joint extensor musculature was assessed on an isokinetic dynamometer, MS of the vastus lateralis (VL) muscle was measured in both relaxed and contracted conditions, and knee joint MAS was quantified using the free oscillation technique. Significant gender differences were observed for all dependent variables. Females demonstrated less normalized PT (mean difference (MD)=0.4Nm/kg, p=0.005, η(2)=0.17), relaxed MS (MD=94.2N/m, p<.001, η(2)=0.53), contracted MS (MD=162.7N/m, p<.001, η(2)=0.53) and MAS (MD=422.1N/m, p<.001, η(2)=0.23) than males. MAS increased linearly with the external load in both genders with males demonstrating a significantly higher slope (p=0.019) than females. The observed differences outlined above may contribute to the higher knee joint injury incidence and prevalence in females when compared to males. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Obesity is associated with higher absolute tibiofemoral contact and muscle forces during gait with and without knee osteoarthritis.

    PubMed

    Harding, Graeme T; Dunbar, Michael J; Hubley-Kozey, Cheryl L; Stanish, William D; Astephen Wilson, Janie L

    2016-01-01

    Obesity is an important risk factor for knee osteoarthritis initiation and progression. However, it is unclear how obesity may directly affect the mechanical loading environment of the knee joint, initiating or progressing joint degeneration. The objective of this study was to investigate the interacting role of obesity and moderate knee osteoarthritis presence on tibiofemoral contact forces and muscle forces within the knee joint during walking gait. Three-dimensional gait analysis was performed on 80 asymptomatic participants and 115 individuals diagnosed with moderate knee osteoarthritis. Each group was divided into three body mass index categories: healthy weight (body mass index<25), overweight (25≤body mass index≤30), and obese (body mass index>30). Tibiofemoral anterior-posterior shear and compressive forces, as well as quadriceps, hamstrings and gastrocnemius muscle forces, were estimated based on a sagittal plane contact force model. Peak contact and muscle forces during gait were compared between groups, as well as the interaction between disease presence and body mass index category, using a two-factor analysis of variance. There were significant osteoarthritis effects in peak shear, gastrocnemius and quadriceps forces only when they were normalized to body mass, and there were significant BMI effects in peak shear, compression, gastrocnemius and hamstrings forces only in absolute, non-normalized forces. There was a significant interaction effect in peak quadriceps muscle forces, with higher forces in overweight and obese groups compared to asymptomatic healthy weight participants. Body mass index was associated with higher absolute tibiofemoral compression and shear forces as well as posterior muscle forces during gait, regardless of moderate osteoarthritis presence or absence. The differences found may contribute to accelerated joint damage with obesity, but with the osteoarthritic knees less able to accommodate the high loads. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Neuromuscular prehabilitation to prevent osteoarthritis after a traumatic joint injury.

    PubMed

    Tenforde, Adam S; Shull, Pete B; Fredericson, Michael

    2012-05-01

    Post-traumatic osteoarthritis (PTOA) is a process resulting from direct forces applied to a joint that cause injury and degenerative changes. An estimated 12% of all symptomatic osteoarthritis (OA) of the hip, knee, and ankle can be attributed to a post-traumatic cause. Neuromuscular prehabilitation is the process of improving neuromuscular function to prevent development of PTOA after an initial traumatic joint injury. Prehabilitation strategies include restoration of normative movement patterns that have been altered as the result of traumatic injury, along with neuromuscular exercises and gait retraining to prevent the development of OA after an injury occurs. A review of the current literature shows that no studies have been performed to evaluate methods of neuromuscular prehabilitation to prevent PTOA after a joint injury. Instead, current research has focused on management strategies after knee injuries, the value of exercise in the management of OA, and neuromuscular exercises after total knee arthroplasty. Recent work in gait retraining that alters knee joint loading holds promise for preventing the development of PTOA after joint trauma. Future research should evaluate methods of neuromuscular prehabilitation strategies in relationship to the outcome of PTOA after joint injury. Copyright © 2012 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  19. Osteoarthritis year in review 2014: mechanics--basic and clinical studies in osteoarthritis.

    PubMed

    Moyer, R F; Ratneswaran, A; Beier, F; Birmingham, T B

    2014-12-01

    The purpose of this review was to highlight recent research in mechanics and osteoarthritis (OA) by summarizing results from selected studies spanning basic and clinical research methods. Databases were searched from January 2013 through to March 2014. Working in pairs, reviewers selected 67 studies categorized into four themes--mechanobiology, ambulatory mechanics, biomechanical interventions and mechanical risk factors. Novel developments in mechanobiology included the identification of cell signaling pathways that mediated cellular responses to loading of articular cartilage. Studies in ambulatory mechanics included an increased focus on instrumented knee implants and progress in computational models, both emphasizing the importance of muscular contributions to load. Several proposed biomechanical interventions (e.g., shoe insoles and knee braces) produced variable changes in external knee joint moments during walking, while meta-analysis of randomized clinical trials did not support the use of lateral wedge insoles for decreasing pain. Results from high quality randomized trials suggested diet with or without exercise decreased indicators of knee joint load during walking, whereas similar effects from exercise alone were not detected with the measures used. Data from longitudinal cohorts suggested mechanical alignment was a risk factor for incidence and progression of OA, with the mechanism involving damage to the meniscus. In combination, the basic and clinical studies highlight the importance of considering multiple contributors to joint loading that can evoke both protective and damaging responses. Although challenges clearly exist, future studies should strive to integrate basic and clinical research methods to gain a greater understanding of the interactions among mechanical factors in OA and to develop improved preventive and therapeutic strategies. Copyright © 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  20. Biomechanical compensations of the trunk and lower extremities during stepping tasks after unilateral transtibial amputation.

    PubMed

    Murray, Amanda M; Gaffney, Brecca M; Davidson, Bradley S; Christiansen, Cory L

    2017-11-01

    Lower extremity movement compensations following transtibial amputation are well-documented and are likely influenced by trunk posture and movement. However, the biomechanical compensations of the trunk and lower extremities, especially during high-demand tasks such as step ascent and descent, remain unclear. Kinematic and kinetic data were collected during step ascent and descent tasks for three groups of individuals: diabetic/transtibial amputation, diabetic, and healthy. An ANCOVA was used to compare peak trunk, hip and knee joint angles and moments in the sagittal and frontal planes between groups. Paired t-tests were used to compare peak joint angles and moments between amputated and intact limbs of the diabetic/transtibial amputation group. During step ascent and descent, the transtibial amputation group exhibited greater trunk forward flexion and lateral flexion compared to the other two groups (P<0.016), which resulted in greater low back moments and asymmetric loading patterns in the lower extremity joints. The diabetic group exhibited similar knee joint loading patterns compared to the amputation group (P<0.016), during step descent. This study highlights the biomechanical compensations of the trunk and lower extremities in individuals with dysvascular transtibial amputation, by identifying low back, hip, and knee joint moment patterns unique to transtibial amputation during stepping tasks. In addition, the results suggest that some movement compensations may be confounded by the presence of diabetes and precede limb amputation. The increased and asymmetrical loading patterns identified may predispose individuals with transtibial amputation to the development of secondary pain conditions, such as low back pain or osteoarthritis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Effects of perturbation or plyometric training on core control and knee joint loading in women during lateral movements.

    PubMed

    Weltin, E; Gollhofer, A; Mornieux, G

    2017-03-01

    Deficits in trunk control are argued to increase the risk of knee injuries. However, no existing training program effectively addresses trunk control during lateral movements, such as cutting maneuvers. The purpose of this study was to investigate whether a combination of perturbation and plyometric training (PPT) would reduce trunk excursions against the new movement direction and reduce knee joint moments during lateral movements. Twenty-four active women participated in a RCT, where trunk and pelvis kinematics and knee joint moments were measured during lateral reactive jumps (LRJ) and unanticipated cutting maneuvers before and after a 4-week PPT program and compared to a control group. During LRJ, trunk rotation away from the new movement direction was reduced (P < 0.001), while pelvis rotation toward the new direction was increased (P = 0.006) after PPT. Moreover, decreased knee extension moments (P = 0.028) and knee internal rotation moments (P < 0.001) were reported after both trainings. Additionally, PPT reduced trunk rotation by 7.2° during unanticipated cuttings. A 4-week PPT improved core control by reducing trunk rotation and reduced knee joint moments during LRJ. During training, perturbations should be introduced to improve core control during dynamic athletic movements, possibly reducing the risk of ACL injuries. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Inflammation is more distinct in temporomandibular joint osteoarthritis compared to the knee joint.

    PubMed

    Vos, Lukas M; Kuijer, Roel; Huddleston Slater, James J R; Bulstra, Sjoerd K; Stegenga, Boudewijn

    2014-01-01

    Most of the current understanding of articular cartilage maintenance and degradation is derived from large load-bearing synovial joints, in particular the knee joint. The aim of this study was to identify valuable degradation markers for cartilage degradation in the temporomandibular joint (TMJ) by comparing the relative concentrations of carboxyterminal telopeptides of collagen types I and II (CTX-I and CTX-II), cartilage oligomeric matrix protein (COMP), and prostaglandin E2 (PGE2) in synovial fluid (SF) of TMJ and knee joints with cartilage degradation. In this cross-sectional comparative study, participants were recruited from the University Medical Center Groningen, The Netherlands. Patients with TMJ osteoarthritis were compared with patients with knee osteoarthritis. The outcome variables were the relative SF concentrations of CTX-I, CTX-II, COMP, and PGE2. An independent samples Mann-Whitney U test was used to compare the relative concentrations. Thirty consecutive patients (9 male, 21 female; mean age, 40.1 yr; standard deviation, 15.3 yr) with TMJ osteoarthritis and 31 consecutive patients (20 male, 11 female; mean age, 37.4 yr; standard deviation, 13.7 yr) who were scheduled for arthroscopy of the knee joint participated in this study. Significant differences were found between relative concentrations of COMP (P = .000) and PGE2 (P = .005), and no significant differences were found between relative concentrations of CTX-I (P = .720) and CTX-II (P = .242). Relative SF concentrations of COMP and PGE2 showed significant differences between the TMJ and the knee joint, suggesting that there are differences in pathophysiology and that the inflammatory component may be more distinct in the TMJ. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Position controlled Knee Rehabilitation Orthotic Device for Patients after Total Knee Replacement Arthroplasty

    NASA Astrophysics Data System (ADS)

    Wannaphan, Patsiri; Chanthasopeephan, Teeranoot

    2016-11-01

    Knee rehabilitation after total knee replacement arthroplasty is essential for patients during their post-surgery recovery period. This study is about designing one degree of freedom knee rehabilitation equipment to assist patients for their post-surgery exercise. The equipment is designed to be used in sitting position with flexion/extension of knee in sagittal plane. The range of knee joint motion is starting from 0 to 90 degrees angle for knee rehabilitation motion. The feature includes adjustable link for different human proportions and the torque feedback control at knee joint during rehabilitation and the control of flexion/extension speed. The motion of the rehabilitation equipment was set to move at low speed (18 degrees/sec) for knee rehabilitation. The rehabilitation link without additional load took one second to move from vertical hanging up to 90° while the corresponding torque increased from 0 Nm to 2 Nm at 90°. When extra load is added, the link took 1.5 seconds to move to 90° The torque is then increased from 0 Nm to 4 Nm. After a period of time, the speed of the motion can be varied. User can adjust the motion to 40 degrees/sec during recovery activity of the knee and users can increase the level of exercise or motion up to 60 degrees/sec to strengthen the muscles during throughout their rehabilitation program depends on each patient. Torque control is included to prevent injury. Patients can use the equipment for home exercise to help reduce the number of hospital visit while the patients can receive an appropriate therapy for their knee recovery program.

  4. Joint contact forces can be reduced by improving joint moment symmetry in below-knee amputee gait simulations.

    PubMed

    Koelewijn, Anne D; van den Bogert, Antonie J

    2016-09-01

    Despite having a fully functional knee and hip in both legs, asymmetries in joint moments of the knee and hip are often seen in gait of persons with a unilateral transtibial amputation (TTA), possibly resulting in excessive joint loading. We hypothesize that persons with a TTA can walk with more symmetric joint moments at the cost of increased effort or abnormal kinematics. The hypothesis was tested using predictive simulations of gait. Open loop controls of one gait cycle were found by solving an optimization problem that minimizes a combination of walking effort and tracking error in joint angles, ground reaction force and gait cycle duration. A second objective was added to penalize joint moment asymmetry, creating a multi-objective optimization problem. A Pareto front was constructed by changing the weights of the objectives and three solutions were analyzed to study the effect of increasing joint moment symmetry. When the optimization placed more weight on moment symmetry, walking effort increased and kinematics became less normal, confirming the hypothesis. TTA gait improved with a moderate increase in joint moment symmetry. At a small cost of effort and abnormal kinematics, the peak hip extension moment in the intact leg was decreased significantly, and so was the joint contact force in the knee and hip. Additional symmetry required a significant increase in walking effort and the joint contact forces in both hips became significantly higher than in able-bodied gait. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Meniscal tears

    PubMed Central

    Maffulli, Nicola; Longo, Umile Giuseppe; Campi, Stefano; Denaro, Vincenzo

    2010-01-01

    The menisci are two semilunar-shaped fibrocartilagenous structures, which are interposed between the femoral condyles and tibial plateaux. They have an important role in knee function. Long-term follow-up studies showed that virtually all meniscectomized knees develop arthritic changes with time. The meniscus has functions in load bearing, load transmission, shock absorption, joint stability, joint lubrication, and joint congruity. Because of these functions, meniscal tissue should be preserved whenever possible. A well-trained surgeon can safely rely on clinical examination for diagnosing meniscal injuries. History and clinical examination are at least as accurate as magnetic resonance imaging in the skilled orthopedic surgeon’s hand. When meniscal repair is not possible, partial resection of the meniscus is indicated. Meniscal repair has evolved from open to arthroscopic techniques, which include the inside-out and outside-in suture repairs and the all-inside techniques. Meniscal transplantation is generally accepted as a management alternative option for selected symptomatic patients with previous complete or near-complete meniscectomy. PMID:24198542

  6. Redistribution of knee stress using laterally wedged insole intervention: Finite element analysis of knee-ankle-foot complex.

    PubMed

    Liu, Xuan; Zhang, Ming

    2013-01-01

    Laterally wedged insoles are widely applied in the conservative treatment for medial knee osteoarthritis. Experimental studies have been conducted to understand the effectiveness of such an orthotic intervention. However, the information was limited to the joint external loading such as knee adduction moment. The internal stress distribution is difficult to be obtained from in vivo experiment alone. Thus, a three-dimensional finite element model of the human knee-ankle-foot complex, together with orthosis, was developed in this study and used to investigate the redistribution of knee stress using laterally wedged insole intervention. Laterally wedged insoles with wedge angles of 0, 5, and 10° were fabricated for intervention. The subject-specific geometry of the lower extremity with details was characterized in the reconstruction of MR images. Motion analysis data and muscle forces were input to drive the model. The established finite element model was employed to investigate the loading responses of tibiofemoral articulation in three wedge angle conditions during simulated walking stance phase. With either of the 5° or 10° laterally wedged insole, significant decreases in von Mises stress and contact force at the medial femur cartilage region and the medial meniscus were predicted comparing with the 0° insole. The diminished stress and contact force at the medial compartment of the knee joint demonstrate the immediate effect of the laterally wedged insoles. The intervention may contribute to medial knee osteoarthritis rehabilitation. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. ESB Clinical Biomechanics Award 2008: Complete data of total knee replacement loading for level walking and stair climbing measured in vivo with a follow-up of 6-10 months.

    PubMed

    Heinlein, Bernd; Kutzner, Ines; Graichen, Friedmar; Bender, Alwina; Rohlmann, Antonius; Halder, Andreas M; Beier, Alexander; Bergmann, Georg

    2009-05-01

    Detailed information about the loading of the knee joint is required for various investigations in total knee replacement. Up to now, gait analysis plus analytical musculo-skeletal models were used to calculate the forces and moments acting in the knee joint. Currently, all experimental and numerical pre-clinical tests rely on these indirect measurements which have limitations. The validation of these methods requires in vivo data; therefore, the purpose of this study was to provide in vivo loading data of the knee joint. A custom-made telemetric tibial tray was used to measure the three forces and three moments acting in the implant. This prosthesis was implanted into two subjects and measurements were obtained for a follow-up of 6 and 10 months, respectively. Subjects performed level walking and going up and down stairs using a self-selected comfortable speed. The subjects' activities were captured simultaneously with the load data on a digital video tape. Customized software enabled the display of all information in one video sequence. The highest mean values of the peak load components from the two subjects were as follows: during level walking the forces were 276%BW (percent body weight) in axial direction, 21%BW (medio-lateral), and 29%BW (antero-posterior). The moments were 1.8%BW*m in the sagittal plane, 4.3%BW*m (frontal plane) and 1.0%BW*m (transversal plane). During stair climbing the axial force increased to 306%BW, while the shear forces changed only slightly. The sagittal plane moment increased to 2.4%BW*m, while the frontal and transversal plane moments decreased slightly. Stair descending produced the highest forces of 352%BW (axial), 35%BW (medio-lateral), and 36%BW (antero-posterior). The sagittal and frontal plane moments increased to 2.8%BW*m and 4.6%BW*m, respectively, while the transversal plane moment changed only slightly. Using the data obtained, mechanical simulators can be programmed according to realistic load profiles. Furthermore, musculo-skeletal models can be validated, which until now often lacked the ability to predict properly the non-sagittal load values, e.g. varus-valgus and internal-external moments.

  8. Wear analysis and finishing of bioceramic implant surfaces.

    PubMed

    Denkena, Berend; Reichstein, Martin; van der Meer, Marijke; Ostermeier, Sven; Hurschler, Christof

    2008-01-01

    A primary cause for revision operations of joint replacements is the implant loosening, due to immune reactions resulting from the agglomeration of polyethylene wear debris. Motivated by the successful application of bioceramic materials in hip joint prostheses, a trend towards the development of hard implant materials has occurred. Nonetheless in the area of total knee arthroplasty (TKA), modern efforts have still utilized polyethylene as the tibial-inlay joint component. The use of bioceramic hard-hard-pairings for total knee arthroplasty has been prevented by the complex kinematics and geometries required. Ceramics cannot cope with non-uniform loads, which suggests the need for new designs appropriate to the material. Furthermore, biomechanical requirements should be considered. A rolling-gliding wear simulator, which reproduces the movements and stresses of the knee joint on specimens of simplified geometry, has therefore been developed. High-precision machining processes for free formed bioceramic surfaces, with suitable grinding and polishing tools which adjust to constantly changing contact conditions, are essential. The goal is to put automated finishing in one clamping with five simultaneous controlled axes into practice. The developed manufacturing technologies will allow the advantageous bioceramic materials to be applied and accepted for more complex joint replacements such as knee prostheses.

  9. Coupling lateral bending and shearing mechanisms to define knee injury criteria for pedestrian safety.

    PubMed

    Mo, Fuhao; Masson, Catherine; Cesari, Dominique; Arnoux, Pierre Jean

    2013-01-01

    In car-pedestrian accidents, lateral bending and shearing kinematics have been identified as principal injury mechanisms causing permanent disabilities and impairments to the knee joint. Regarding the combined lateral bending and shearing contributions of knee joint kinematics, developing a coupled knee injury criterion is necessary for improving vehicle countermeasures to mitigate pedestrian knee injuries. The advantages of both experimental tests and finite element (FE) simulations were combined to determine the reliable injury tolerances of the knee joint. First, 7 isolated lower limb tests from postmortem human subjects (PMHS) were reported, with dynamic loading at a velocity of 20 km/h. With the intention of replicating relevant injury mechanisms of vehicle-pedestrian impacts, the experimental tests were categorized into 3 groups by the impact locations on the tibia: the distal end to prioritize pure bending, the middle diaphysis to have combined bending and shearing effects, and the proximal end to acquire pure shearing. Then, the corresponding FE model was employed to provide an additional way to determine exact injury occurrences and develop a robust knee injury criterion by the variation in both the lateral bending and shearing contributions through a sensitivity analysis of impact locations. Considering the experimental test results and the subsequent sensitivity analysis of FE simulations, both the tolerances and patterns of knee joint injuries were determined to be influenced by impact locations due to various combined contributions of lateral bending and shearing. Both medial collateral ligament and cruciate ligament failures were noted as the onsets of knee injuries, namely, initial injuries. Finally, a new injury criterion categorized by initial injury patterns of knee joint was proposed by coupling lateral bending and shearing levels. The developed injury criterion correlated the combined joint kinematics to initial knee injuries based on subsegment tests and FE simulations conducted with a biofidelic lower limb model. This provides a valuable way of predicting the risk of knee injury associated with vehicle-pedestrian crashes and thereby represents a further step to promote the design of vehicle countermeasures for pedestrian safety.

  10. Reflex Responses to Ligament Loading: Implications for Knee Joint Stability

    DTIC Science & Technology

    2001-10-25

    white noise approach", Prentice-Hall".:, 1978. [15] B. Grenfield and B. Wyke, "Reflex innervation of the temporo - mandibular joint .". Nature. 211(52...selective, depending on the magnitude of the angular perturbation. Keywords - Reflex, Periarticular tissue afferents, Joint stability I...INTRODUCTION Traditionally, joint stability has been considered to be purely mechanical in origin, with little or no consideration of neuromuscular

  11. Effects of neuromuscular fatigue on perceptual-cognitive skills between genders in the contribution to the knee joint loading during side-stepping tasks.

    PubMed

    Khalid, Abdul Jabbar; Harris, Sujae Ian; Michael, Loke; Joseph, Hamill; Qu, Xingda

    2015-01-01

    This study investigated whether neuromuscular fatigue affects the neuromuscular control of an athlete within a sports context setting and whether these effects were more pronounced in the females. Lower limb joint kinetics of 6 male and 6 female inter-varsity soccer players performing side-stepping tasks in non-fatigue versus fatigue and anticipated versus unanticipated conditions were quantified using 10 Motion Analysis Corporation cameras and a Kistler(™) force platform. The Yo-Yo intermittent recovery Level 1 fatigue protocol was employed. Stance foot initial contact and peak forces, and peak joint knee moments of the lower limb were submitted to a 3-way mixed-model repeated measure ANOVA. The results suggested that males tend to elicit significantly higher knee joint loadings when fatigued. In addition, males elicited significantly higher peak proximal tibia anterior/posterior shear force, vertical ground reaction force at initial contact and peak internal rotational moments than females. These findings suggested that males were at greater overall injury risk than females, especially in the sagittal plane. Neuromuscular control-based training programmes/interventions that are designed to reduce the risk of the non-contact ACL injury need to be customised for the different genders.

  12. Effects of Initial Graft Tension on the Tibiofemoral Compressive Forces and Joint Position Following ACL Reconstruction

    PubMed Central

    Brady, Mark F.; Bradley, Michael P.; Fleming, Braden C.; Fadale, Paul D.; Hulstyn, Michael J.; Banerjee, Rahul

    2007-01-01

    Background The initial tension applied to an ACL graft at the time of fixation modulates knee motion and the tibiofemoral compressive loads. Purpose To establish the relationships between initial graft tension, tibiofemoral compressive force, and the neutral tibiofemoral position in the cadaver knee. Study Design Controlled Laboratory Study. Methods The tibiofemoral compressive forces and joint positions were determined in the ACL-intact knee at 0°, 20° and 90° knee flexion. The ACL was excised and reconstructed with a patellar tendon graft using graft tensions of 1, 15, 30, 60 and 90 N applied at 0°, 20° and 90° knee flexion. The compressive forces and neutral positions were compared between initial tension conditions and the ACL-intact knee. Results Increasing initial graft tension increased the tibiofemoral compressive forces. The forces in the medial compartment were 1.8 times those in the lateral compartment. The compressive forces were dependent on the knee angle at which the tension was applied. The greatest compressive forces occurred when the graft was tensioned with the knee in extension. An increase in initial graft tension caused the tibia to rotate externally compared to the ACL-intact knee. Increases in initial graft tension also caused a significant posterior translation of the tibia relative to the femur. Conclusions Different initial graft tension protocols produced predictable changes in the tibiofemoral compressive forces and joint positions. Clinical Relevance The tibiofemoral compressive force and neutral joint position were best replicated with a low graft tension (1–15 N) when using a patellar tendon graft. PMID:17218659

  13. Effects of a 10-week toe-out gait modification intervention in people with medial knee osteoarthritis: a pilot, feasibility study.

    PubMed

    Hunt, M A; Takacs, J

    2014-07-01

    To examine the feasibility of a 10-week gait modification program in people with medial tibiofemoral knee osteoarthritis (OA), and to assess changes in clinical and biomechanical outcomes. Fifteen people with medial knee OA completed 10 weeks of gait modification focusing on increasing toe-out angle during stance 10° compared to their self-selected angle measured at baseline. In addition to adherence and performance difficulty outcomes, knee joint symptoms (Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain subscale and total score, numerical rating scale (NRS) of pain), and knee joint loading during gait (late stance peak knee adduction moment (KAM)) were assessed. Participants were able to perform the toe-out gait modification program with minimal to moderate difficulty, and exhibited significant increases in self-selected toe-out angle during walking (P < 0.001). Joint discomfort was reported by five participants (33%) in the hip or knee joints, though none lasted longer than 2 weeks. Participants reported statistically significant reductions in WOMAC pain (P = 0.02), NRS pain (P < 0.001), WOMAC total score (P = 0.02), and late stance KAM (P = 0.04). These preliminary findings suggest that toe-out gait modification is feasible in people with medial compartment knee OA. Preliminary changes in clinical and biomechanical outcomes provide the impetus for conducting larger scale studies of gait modification in people with knee OA to confirm these findings. Copyright © 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  14. Knee motion variability in patients with knee osteoarthritis: the effect of self-reported instability

    PubMed Central

    Gustafson, Jonathan A.; Robinson, Megan E.; Fitzgerald, G. Kelley; Tashman, Scott; Farrokhi, Shawn

    2015-01-01

    Background Knee osteoarthritis has been previously associated with a stereotypical knee-stiffening gait pattern and reduced knee joint motion variability due to increased antagonist muscle co-contractions and smaller utilized arc of motion during gait. However, episodic self-reported instability may be a sign of excessive motion variability for a large subgroup of patients with knee osteoarthritis. The objective of this work was to evaluate the differences in knee joint motion variability during gait in patients with knee osteoarthritis with and without self-reported instability compared to a control group of older adults with asymptomatic knees. Methods Forty-three subjects, 8 with knee osteoarthritis but no reports of instability (stable), 11 with knee osteoarthritis and self-reported instability (unstable), and 24 without knee osteoarthritis or instability (control) underwent Dynamic Stereo X-ray analysis during a decline gait task on a treadmill. Knee motion variability was assessed using parametric phase plots during the loading response phase of decline gait. Findings The stable group demonstrated decreased sagittal-plane motion variability compared to the control group (p=0.04), while the unstable group demonstrated increased sagittal-plane motion variability compared to the control (p=0.003) and stable groups (p<0.001). The unstable group also demonstrated increased anterior-posterior joint contact point motion variability for the medial tibiofemoral compartment compared to the control (p=0.03) and stable groups (p=0.03). Interpretation The finding of decreased knee motion variability in patients with knee osteoarthritis without self-reported instability supports previous research. However, presence of self-reported instability is associated with increased knee motion variability in patients with knee osteoarthritis and warrants further investigation. PMID:25796536

  15. Foot positioning instruction, initial vertical load position and lifting technique: effects on low back loading.

    PubMed

    Kingma, Idsart; Bosch, Tim; Bruins, Louis; van Dieën, Jaap H

    2004-10-22

    This study investigated the effects of initial load height and foot placement instruction in four lifting techniques: free, stoop (bending the back), squat (bending the knees) and a modified squat technique (bending the knees and rotating them outward). A 2D dynamic linked segment model was combined with an EMG assisted trunk muscle model to quantify kinematics and low back loading in 10 subjects performing 19 different lifting movements, using 10.5 kg boxes without handles. When lifting from a 0.05 m height with the feet behind the box, squat lifting resulted in 19.9% (SD 8.7%) higher net moments (p < 0.001) and 17.0% (SD 13.2%) higher compression forces (p < 0.01) than stoop lifting. This effect was reduced to 12.8% (SD 10.7%) for moments and a non-significant 7.4% (SD 16.0%) for compression forces when lifting with the feet beside the box and it disappeared when lifting from 0.5 m height. Differences between squat and stoop lifts, as well as the interaction with lifting height, could to a large extent be explained by changes in the horizontal L5/S1 intervertebral joint position relative to the load, the upper body acceleration, and lumbar flexion. Rotating the knees outward during squat lifts resulted in moments and compression forces that were smaller than in squat lifting but larger than in stoop lifting. Shear forces were small ( < 300 N) at the L4/L5 joint and substantial (1100 - 1400 N) but unaffected by lifting technique at the L5/S1 joint. The present results show that the effects of lifting technique on low back loading depend on the task context.

  16. Knee and Hip Joint Kinematics Predict Quadriceps and Hamstrings Neuromuscular Activation Patterns in Drop Jump Landings.

    PubMed

    Malfait, Bart; Dingenen, Bart; Smeets, Annemie; Staes, Filip; Pataky, Todd; Robinson, Mark A; Vanrenterghem, Jos; Verschueren, Sabine

    2016-01-01

    The purpose was to assess if variation in sagittal plane landing kinematics is associated with variation in neuromuscular activation patterns of the quadriceps-hamstrings muscle groups during drop vertical jumps (DVJ). Fifty female athletes performed three DVJ. The relationship between peak knee and hip flexion angles and the amplitude of four EMG vectors was investigated with trajectory-level canonical correlation analyses over the entire time period of the landing phase. EMG vectors consisted of the {vastus medialis(VM),vastus lateralis(VL)}, {vastus medialis(VM),hamstring medialis(HM)}, {hamstring medialis(HM),hamstring lateralis(HL)} and the {vastus lateralis(VL),hamstring lateralis(HL)}. To estimate the contribution of each individual muscle, linear regressions were also conducted using one-dimensional statistical parametric mapping. The peak knee flexion angle was significantly positively associated with the amplitudes of the {VM,HM} and {HM,HL} during the preparatory and initial contact phase and with the {VL,HL} vector during the peak loading phase (p<0.05). Small peak knee flexion angles were significantly associated with higher HM amplitudes during the preparatory and initial contact phase (p<0.001). The amplitudes of the {VM,VL} and {VL,HL} were significantly positively associated with the peak hip flexion angle during the peak loading phase (p<0.05). Small peak hip flexion angles were significantly associated with higher VL amplitudes during the peak loading phase (p = 0.001). Higher external knee abduction and flexion moments were found in participants landing with less flexed knee and hip joints (p<0.001). This study demonstrated clear associations between neuromuscular activation patterns and landing kinematics in the sagittal plane during specific parts of the landing. These findings have indicated that an erect landing pattern, characterized by less hip and knee flexion, was significantly associated with an increased medial and posterior neuromuscular activation (dominant hamstrings medialis activity) during the preparatory and initial contact phase and an increased lateral neuromuscular activation (dominant vastus lateralis activity) during the peak loading phase.

  17. Kinematics of Different Components of the Posterolateral Corner of the Knee in the Lateral Collateral Ligament-intact State: A Human Cadaveric Study.

    PubMed

    Domnick, Christoph; Frosch, Karl-Heinz; Raschke, Michael J; Vogel, Nils; Schulze, Martin; von Glahn, Mathias; Drenck, Tobias C; Herbort, Mirco

    2017-10-01

    To determine the static stabilizing effects of different anatomical structures of the posterolateral corner (PLC) of the knee in the lateral collateral ligament (LCL)-intact state. Thirteen fresh-frozen human cadaveric knees were dissected and tested using an industrial robot with an optical tracking system. Kinematics were determined for 134 N anterior/posterior loads, 10 N m valgus/varus loads, and 5 N m internal/external rotatory loads in 0°, 20°, 30°, 60°, and 90° of knee flexion. The PLC structures were dissected and consecutively released: (I) intact knee joint, (II) with released posterior cruciate ligament (PCL), (III) popliteomeniscal fibers, (IV) popliteofibular ligament, (V) arcuat and popliteotibial fibers, (VI) popliteus tendon (PLT), and (VII) LCL. Repeated-measures analysis of variance was performed with significance set at P < .05. After releasing the PCL, posterior tibial translation increased by 5.2 mm at 20° to 9.4 mm at 90° of joint flexion (P < .0001). A mild 1.8° varus instability was measured in 0° of flexion (P = .0017). After releasing the PLC structures, posterior tibial translation further increased by 2.9 mm at 20° to 5.9 mm at 90° of flexion (P < .05) and external rotation angle increased by 2.6° at 0° to 7.9° at 90° of flexion (P < .05, vs II). Varus stability did not decrease. Mild differences between states V and VI were found in 60° and 90° external rotation tests (2.1° and 3.1°; P < .05). The connecting ligaments/fibers to the PLT act as a primary static stabilizer against external rotatory loads and a secondary stabilizer against posterior tibial loads (when PCL is injured). After releasing these structures, most static stabilizing function of the intact PLT is lost. The PLC has no varus-stabilizing function in the LCL-intact knee. Anatomy and function of these structures for primary and secondary joint stability should be considered for clinical diagnostics and when performing surgery in the PLC. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  18. Functional roles of lower-limb joint moments while walking in water.

    PubMed

    Miyoshi, Tasuku; Shirota, Takashi; Yamamoto, Shin-Ichiro; Nakazawa, Kimitaka; Akai, Masami

    2005-02-01

    To clarify the functional roles of lower-limb joint moments and their contribution to support and propulsion tasks while walking in water compared with that on land. Sixteen healthy, young subjects walked on land and in water at several different speeds with and without additional loads. Walking in water is a major rehabilitation therapy for patients with orthopedic disorders. However, the functional role of lower-limb joint moments while walking in water is still unclear. Kinematics, electromyographic activities in biceps femoris and gluteus maximums, and ground reaction forces were measured under the following conditions: walking on land and in water at a self-determined pace, slow walking on land, and fast walking in water with or without additional loads (8 kg). The hip, knee, and ankle joint moments were calculated by inverse dynamics. The contribution of the walking speed increased the hip extension moment, and the additional weight increased the ankle plantar flexion and knee extension moment. The major functional role was different in each lower-limb joint muscle. That of the muscle group in the ankle is to support the body against gravity, and that of the muscle group involved in hip extension is to contribute to propulsion. In addition, walking in water not only reduced the joint moments but also completely changed the inter-joint coordination. It is of value for clinicians to be aware that the greater the viscosity of water produces a greater load on the hip joint when fast walking in water.

  19. Biomechanical effects of valgus knee bracing: a systematic review and meta-analysis.

    PubMed

    Moyer, R F; Birmingham, T B; Bryant, D M; Giffin, J R; Marriott, K A; Leitch, K M

    2015-02-01

    To review and synthesize the biomechanical effects of valgus knee bracing for patients with medial knee osteoarthritis (OA). Electronic databases were searched from their inception to May 2014. Two reviewers independently determined study eligibility, rated study quality and extracted data. Where possible, data were combined into meta-analyses and pooled estimates with 95% confidence intervals (CI) for standardized mean differences (SMD) were calculated. Thirty studies were included with 478 subjects tested while using a valgus knee brace. Various biomechanical methods suggested valgus braces can decrease direct measures of medial knee compressive force, indirect measures representing the mediolateral distribution of load across the knee, quadriceps/hamstring and quadriceps/gastrocnemius co-contraction ratios, and increase medial joint space during gait. Meta-analysis from 17 studies suggested a statistically significant decrease in the external knee adduction moment (KAM) during walking, with a moderate-to-high effect size (SMD = 0.61; 95% CI: 0.39, 0.83; P < 0.001). Meta-regression identified a near-significant association for the KAM effect size and duration of brace use only (β, -0.01; 95% CI: -0.03, 0.0001; P = 0.06); with longer durations of brace use associated with smaller treatment effects. Minor complications were commonly reported during brace use and included slipping, discomfort and poor fit, blisters and skin irritation. Systematic review and meta-analysis suggests valgus knee braces can alter knee joint loads through a combination of mechanisms, with moderate-to-high effect sizes in biomechanical outcomes. Copyright © 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  20. The effect of exercise therapy on knee adduction moment in individuals with knee osteoarthritis: A systematic review.

    PubMed

    Ferreira, Giovanni E; Robinson, Caroline Cabral; Wiebusch, Matheus; Viero, Carolina Cabral de Mello; da Rosa, Luis Henrique Telles; Silva, Marcelo Faria

    2015-07-01

    Exercise therapy is an evidence-based intervention for the conservative management of knee osteoarthritis. It is hypothesized that exercise therapy could reduce the knee adduction moment. A systematic review was performed in order to verify the effects of exercise therapy on the knee adduction moment in individuals with knee osteoarthritis in studies that also assessed pain and physical function. A comprehensive electronic search was performed on MEDLINE, Cochrane CENTRAL, EMBASE, Google scholar and OpenGrey. Inclusion criteria were randomized controlled trials with control or sham groups as comparator assessing pain, physical function, muscle strength and knee adduction moment during walking at self-selected speed in individuals with knee osteoarthritis that underwent a structured exercise therapy rehabilitation program. Two independent reviewers extracted the data and assessed risk of bias. For each study, knee adduction moment, pain and physical function outcomes were extracted. For each outcome, mean differences and 95% confidence intervals were calculated. Due to clinical heterogeneity among exercise therapy protocols, a descriptive analysis was chosen. Three studies, comprising 233 participants, were included. None of the studies showed significant differences between strengthening and control/sham groups in knee adduction moment. In regards to pain and physical function, the three studies demonstrated significant improvement in pain and two of them showed increased physical function following exercise therapy compared to controls. Muscle strength and torque significantly improved in all the three trials favoring the intervention group. Clinical benefits from exercise therapy were not associated with changes in the knee adduction moment. The lack of knee adduction moment reduction indicates that exercise therapy may not be protective in knee osteoarthritis from a joint loading point of view. Alterations in neuromuscular control, not captured by the knee adduction moment measurement, may contribute to alter dynamic joint loading following exercise therapy. To conclude, mechanisms other than the reduction in knee adduction moment might explain the clinical benefits of exercise therapy on knee osteoarthritis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Kinematic and kinetic synergies of the lower extremities during the pull in olympic weightlifting.

    PubMed

    Kipp, Kristof; Redden, Josh; Sabick, Michelle; Harris, Chad

    2012-07-01

    The purpose of this study was to identify multijoint lower extremity kinematic and kinetic synergies in weightlifting and compare these synergies between joints and across different external loads. Subjects completed sets of the clean exercise at loads equal to 65, 75, and 85% of their estimated 1-RM. Functional data analysis was used to extract principal component functions (PCF's) for hip, knee, and ankle joint angles and moments of force during the pull phase of the clean at all loads. The PCF scores were then compared between joints and across loads to determine how much of each PCF was present at each joint and how it differed across loads. The analyses extracted two kinematic and four kinetic PCF's. The statistical comparisons indicated that all kinematic and two of the four kinetic PCF's did not differ across load, but scaled according to joint function. The PCF's captured a set of joint- and load-specific synergies that quantified biomechanical function of the lower extremity during Olympic weightlifting and revealed important technical characteristics that should be considered in sports training and future research.

  2. The Interaction of Trunk-Load and Trunk-Position Adaptations on Knee Anterior Shear and Hamstrings Muscle Forces During Landing

    PubMed Central

    Kulas, Anthony S.; Hortobágyi, Tibor; DeVita, Paul

    2010-01-01

    Abstract Context: Because anterior cruciate ligament (ACL) injuries can occur during deceleration maneuvers, biomechanics research has been focused on the lower extremity kinetic chain. Trunk mass and changes in trunk position affect lower extremity joint torques and work during gait and landing, but how the trunk affects knee joint and muscle forces is not well understood. Objective: To evaluate the effects of added trunk load and adaptations to trunk position on knee anterior shear and knee muscle forces in landing. Design: Crossover study. Setting: Controlled laboratory environment. Patients or Other Participants: Twenty-one participants (10 men: age  =  20.3 ± 1.15 years, height  =  1.82 ± 0.04 m, mass  =  78.2 ± 7.3 kg; 11 women: age  =  20.0 ± 1.10 years, height  =  1.72 ± 0.06 m, mass  =  62.3 ± 6.4 kg). Intervention(s): Participants performed 2 sets of 8 double-leg landings under 2 conditions: no load and trunk load (10% body mass). Participants were categorized into one of 2 groups based on the kinematic trunk adaptation to the load: trunk flexor or trunk extensor. Main Outcome Measure(s): We estimated peak and average knee anterior shear, quadriceps, hamstrings, and gastrocnemius forces with a biomechanical model. Results: We found condition-by-group interactions showing that adding a trunk load increased peak (17%) and average (35%) knee anterior shear forces in the trunk-extensor group but did not increase them in the trunk-flexor group (peak: F1,19  =  10.56, P  =  .004; average: F1,19  =  9.56, P  =  .006). We also found a main effect for condition for quadriceps and gastrocnemius forces. When trunk load was added, peak (6%; F1,19  =  5.52, P  =  .030) and average (8%; F1,19  =  8.83, P  =  .008) quadriceps forces increased and average (4%; F1,19  =  4.94, P  =  .039) gastrocnemius forces increased, regardless of group. We found a condition-by-group interaction for peak (F1,19  =  5.16, P  =  .035) and average (F1,19  =  12.35, P  =  .002) hamstrings forces. When trunk load was added, average hamstrings forces decreased by 16% in the trunk-extensor group but increased by 13% in the trunk-flexor group. Conclusions: Added trunk loads increased knee anterior shear and knee muscle forces, depending on trunk adaptation strategy. The trunk-extensor adaptation to the load resulted in a quadriceps-dominant strategy that increased knee anterior shear forces. Trunk-flexor adaptations may serve as a protective strategy against the added load. These findings should be interpreted with caution, as only the face validity of the biomechanical model was assessed. PMID:20064042

  3. Above-knee prosthesis design based on fatigue life using finite element method and design of experiment.

    PubMed

    Phanphet, Suwattanarwong; Dechjarern, Surangsee; Jomjanyong, Sermkiat

    2017-05-01

    The main objective of this work is to improve the standard of the existing design of knee prosthesis developed by Thailand's Prostheses Foundation of Her Royal Highness The Princess Mother. The experimental structural tests, based on the ISO 10328, of the existing design showed that a few components failed due to fatigue under normal cyclic loading below the required number of cycles. The finite element (FE) simulations of structural tests on the knee prosthesis were carried out. Fatigue life predictions of knee component materials were modeled based on the Morrow's approach. The fatigue life prediction based on the FE model result was validated with the corresponding structural test and the results agreed well. The new designs of the failed components were studied using the design of experimental approach and finite element analysis of the ISO 10328 structural test of knee prostheses under two separated loading cases. Under ultimate loading, knee prosthesis peak von Mises stress must be less than the yield strength of knee component's material and the total knee deflection must be lower than 2.5mm. The fatigue life prediction of all knee components must be higher than 3,000,000 cycles under normal cyclic loading. The design parameters are the thickness of joint bars, the diameter of lower connector and the thickness of absorber-stopper. The optimized knee prosthesis design meeting all the requirements was recommended. Experimental ISO 10328 structural test of the fabricated knee prosthesis based on the optimized design confirmed the finite element prediction. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  4. Knee Kinetics during Squats of Varying Loads and Depths in Recreationally Trained Females.

    PubMed

    Flores, Victoria; Becker, James; Burkhardt, Eric; Cotter, Joshua

    2018-03-06

    The back squat exercise is typically practiced with varying squat depths and barbell loads. However, depth has been inconsistently defined, resulting in unclear safety precautions when squatting with loads. Additionally, females exhibit anatomical and kinematic differences to males which may predispose them to knee joint injuries. The purpose of this study was to characterize peak knee extensor moments (pKEMs) at three commonly practiced squat depths of above parallel, parallel, and full depth, and with three loads of 0% (unloaded), 50%, and 85% depth-specific one repetition maximum (1RM) in recreationally active females. Nineteen females (age, 25.1 ± 5.8 years; body mass, 62.5 ± 10.2 kg; height, 1.6 ± 0.10 m; mean ± SD) performed squats of randomized depth and load. Inverse dynamics were used to obtain pKEMs from three-dimensional knee kinematics. Depth and load had significant interaction effects on pKEMs (p = 0.014). Significantly greater pKEMs were observed at full depth compared to parallel depth with 50% 1RM load (p = 0.001, d = 0.615), and 85% 1RM load (p = 0.010, d = 0.714). Greater pKEMs were also observed at full depth compared to above parallel depth with 50% 1RM load (p = 0.003, d = 0.504). Results indicate effect of load on female pKEMs do not follow a progressively increasing pattern with either increasing depth or load. Therefore, when high knee loading is a concern, individuals are must carefully consider both the depth of squat being performed and the relative load they are using.

  5. The influence of patellofemoral joint contact geometry on the modeling of three dimensional patellofemoral joint forces.

    PubMed

    Powers, Christopher M; Chen, Yu-Jen; Scher, Irving; Lee, Thay Q

    2006-01-01

    The purpose of this study was to determine the influence of patellofemoral joint contact geometry on the modeling of three-dimensional patellofemoral joint forces. To achieve this goal, patellofemoral joint reaction forces (PFJRFs) that were measured from an in-vitro cadaveric set-up were compared to PFJRFs estimated from a computer model that did not consider patellofemoral joint contact geometry. Ten cadaver knees were used in this study. Each was mounted on a custom jig that was fixed to an Instron frame. Quadriceps muscle loads were accomplished using a pulley system and weights. The force in the patellar ligament was obtained using a buckle transducer. To quantify the magnitude and direction of the PFJRF, a six-axis load cell was incorporated into the femoral fixation system so that a rigid body assumption could be made. PFJRF data were obtained at 0 degrees , 20 degrees , 40 degrees and 60 degrees of knee flexion. Following in vitro testing, SIMM modeling software was used to develop computational models based on the three-dimensional coordinates (Microscribe digitizer) of individual muscle and patellar ligament force vectors obtained from the cadaver knees. The overall magnitude of the PFJRF estimated from the computer generated models closely matched the direct measurements from the in vitro set-up (Pearson's correlation coefficient, R(2)=0.91, p<0.001). Although the computational model accurately estimated the posteriorly directed forces acting on the joint, some discrepancies were noted in the forces acting in the superior and lateral directions. These differences however, were relatively small when expressed as a total of the overall PFJRF magnitude.

  6. Resistance training alters the sensorimotor control of vasti muscles.

    PubMed

    Wong, Y M; Ng, Gabriel

    2010-02-01

    The present study examined and compared two modes of weight training (bodybuilding and power-lifting) on the surface EMG of vasti muscles, knee joint position sense and isometric knee extension force in 48 able-bodied subjects. Subjects were randomly allocated into either a moderate loading and repetitions (bodybuilding) training or a high loading and low repetitions (power-lifting) training, or a no training control group. Training was conducted on alternate days with individual supervision. After 8 weeks of training, subjects from both training groups showed significantly earlier EMG onset timing and higher amplitude of vastus medialis obliquus relative to vastus lateralis (p=0.005 or <0.001), and improved knee joint position sense (p<0.001), but no such changes were found in the control group. However, the changes were not significantly different (p>0.05) between the two training groups. The findings suggested that the neuromotor control of the vasti muscles could be altered by regular weight training.

  7. Optimization of prosthetic foot stiffness to reduce metabolic cost and intact knee loading during below-knee amputee walking: a theoretical study.

    PubMed

    Fey, Nicholas P; Klute, Glenn K; Neptune, Richard R

    2012-11-01

    Unilateral below-knee amputees develop abnormal gait characteristics that include bilateral asymmetries and an elevated metabolic cost relative to non-amputees. In addition, long-term prosthesis use has been linked to an increased prevalence of joint pain and osteoarthritis in the intact leg knee. To improve amputee mobility, prosthetic feet that utilize elastic energy storage and return (ESAR) have been designed, which perform important biomechanical functions such as providing body support and forward propulsion. However, the prescription of appropriate design characteristics (e.g., stiffness) is not well-defined since its influence on foot function and important in vivo biomechanical quantities such as metabolic cost and joint loading remain unclear. The design of feet that improve these quantities could provide considerable advancements in amputee care. Therefore, the purpose of this study was to couple design optimization with dynamic simulations of amputee walking to identify the optimal foot stiffness that minimizes metabolic cost and intact knee joint loading. A musculoskeletal model and distributed stiffness ESAR prosthetic foot model were developed to generate muscle-actuated forward dynamics simulations of amputee walking. Dynamic optimization was used to solve for the optimal muscle excitation patterns and foot stiffness profile that produced simulations that tracked experimental amputee walking data while minimizing metabolic cost and intact leg internal knee contact forces. Muscle and foot function were evaluated by calculating their contributions to the important walking subtasks of body support, forward propulsion and leg swing. The analyses showed that altering a nominal prosthetic foot stiffness distribution by stiffening the toe and mid-foot while making the ankle and heel less stiff improved ESAR foot performance by offloading the intact knee during early to mid-stance of the intact leg and reducing metabolic cost. The optimal design also provided moderate braking and body support during the first half of residual leg stance, while increasing the prosthesis contributions to forward propulsion and body support during the second half of residual leg stance. Future work will be directed at experimentally validating these results, which have important implications for future designs of prosthetic feet that could significantly improve amputee care.

  8. Knee joint passive stiffness and moment in sagittal and frontal planes markedly increase with compression.

    PubMed

    Marouane, H; Shirazi-Adl, A; Adouni, M

    2015-01-01

    Knee joints are subject to large compression forces in daily activities. Due to artefact moments and instability under large compression loads, biomechanical studies impose additional constraints to circumvent the compression position-dependency in response. To quantify the effect of compression on passive knee moment resistance and stiffness, two validated finite element models of the tibiofemoral (TF) joint, one refined with depth-dependent fibril-reinforced cartilage and the other less refined with homogeneous isotropic cartilage, are used. The unconstrained TF joint response in sagittal and frontal planes is investigated at different flexion angles (0°, 15°, 30° and 45°) up to 1800 N compression preloads. The compression is applied at a novel joint mechanical balance point (MBP) identified as a point at which the compression does not cause any coupled rotations in sagittal and frontal planes. The MBP of the unconstrained joint is located at the lateral plateau in small compressions and shifts medially towards the inter-compartmental area at larger compression forces. The compression force substantially increases the joint moment-bearing capacities and instantaneous angular rigidities in both frontal and sagittal planes. The varus-valgus laxities diminish with compression preloads despite concomitant substantial reductions in collateral ligament forces. While the angular rigidity would enhance the joint stability, the augmented passive moment resistance under compression preloads plays a role in supporting external moments and should as such be considered in the knee joint musculoskeletal models.

  9. A rolling-gliding wear simulator for the investigation of tribological material pairings for application in total knee arthroplasty.

    PubMed

    Richter, Berna I; Ostermeier, Sven; Turger, Anke; Denkena, Berend; Hurschler, Christof

    2010-06-15

    Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only. A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made. The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures. The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in knee joint replacement implants.

  10. A rolling-gliding wear simulator for the investigation of tribological material pairings for application in total knee arthroplasty

    PubMed Central

    2010-01-01

    Background Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only. Methods A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made. Results The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures. Conclusions The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in knee joint replacement implants. PMID:20550669

  11. The Effects of Walking Speed on Tibiofemoral Loading Estimated Via Musculoskeletal Modeling

    PubMed Central

    Lerner, Zachary F.; Haight, Derek J.; DeMers, Matthew S.; Board, Wayne J.; Browning, Raymond C.

    2015-01-01

    Net muscle moments (NMMs) have been used as proxy measures of joint loading, but musculoskeletal models can estimate contact forces within joints. The purpose of this study was to use a musculoskeletal model to estimate tibiofemoral forces and to examine the relationship between NMMs and tibiofemoral forces across walking speeds. We collected kinematic, kinetic, and electromyographic data as ten adult participants walked on a dual-belt force-measuring treadmill at 0.75, 1.25, and 1.50 m/s. We scaled a musculoskeletal model to each participant and used OpenSim to calculate the NMMs and muscle forces through inverse dynamics and weighted static optimization, respectively. We determined tibiofemoral forces from the vector sum of intersegmental and muscle forces crossing the knee. Estimated tibiofemoral forces increased with walking speed. Peak early-stance compressive tibiofemoral forces increased 52% as walking speed increased from 0.75 to 1.50 m/s, whereas peak knee extension NMMs increased by 168%. During late stance, peak compressive tibiofemoral forces increased by 18% as speed increased. Although compressive loads at the knee did not increase in direct proportion to NMMs, faster walking resulted in greater compressive forces during weight acceptance and increased compressive and anterior/posterior tibiofemoral loading rates in addition to a greater abduction NMM. PMID:23878264

  12. Compressive tibiofemoral force during crouch gait.

    PubMed

    Steele, Katherine M; Demers, Matthew S; Schwartz, Michael H; Delp, Scott L

    2012-04-01

    Crouch gait, a common walking pattern in individuals with cerebral palsy, is characterized by excessive flexion of the hip and knee. Many subjects with crouch gait experience knee pain, perhaps because of elevated muscle forces and joint loading. The goal of this study was to examine how muscle forces and compressive tibiofemoral force change with the increasing knee flexion associated with crouch gait. Muscle forces and tibiofemoral force were estimated for three unimpaired children and nine children with cerebral palsy who walked with varying degrees of knee flexion. We scaled a generic musculoskeletal model to each subject and used the model to estimate muscle forces and compressive tibiofemoral forces during walking. Mild crouch gait (minimum knee flexion 20-35°) produced a peak compressive tibiofemoral force similar to unimpaired walking; however, severe crouch gait (minimum knee flexion>50°) increased the peak force to greater than 6 times body-weight, more than double the load experienced during unimpaired gait. This increase in compressive tibiofemoral force was primarily due to increases in quadriceps force during crouch gait, which increased quadratically with average stance phase knee flexion (i.e., crouch severity). Increased quadriceps force contributes to larger tibiofemoral and patellofemoral loading which may contribute to knee pain in individuals with crouch gait. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. THE BIOMECHANICAL RESPONSE OF PERSONS WITH TRANSFEMORAL AMPUTATION TO VARIATIONS IN PROSTHETIC KNEE ALIGNMENT DURING LEVEL WALKING

    PubMed Central

    Koehler-McNicholas, Sara R.; Lipschutz, Robert D.; Gard, Steven A.

    2017-01-01

    Prosthetic alignment is an important factor in the overall fit and performance of a lower-limb prosthesis. However, the association between prosthetic alignment and control strategies used by persons with transfemoral amputation to coordinate the movement of a passive prosthetic knee is poorly understood. This study investigated the biomechanical response of persons with transfemoral amputation to systematic perturbations in knee joint alignment during a level walking task. Quantitative gait data were collected for three alignment conditions: bench alignment, 2 cm anterior knee translation (ANT), and 2 cm posterior knee translation (POST). In response to a destabilizing alignment perturbation (ANT), subjects significantly increased their early-stance hip extension moment, confirming that persons with transfemoral amputation rely on a hip extensor strategy to maintain knee joint stability. However, subjects also decreased the rate at which they loaded their prosthesis, decreased their step length, increased their trunk flexion, and maintained their limb in a more vertical posture at the time of opposite toe off. Collectively, these results suggest that persons with transfemoral amputation rely on a combination of strategies to coordinate stance-phase knee flexion. Further, no significant changes were observed in response to the POST condition, suggesting that a bias toward posterior alignment may have fewer implications in terms of stance-phase, knee-joint control. PMID:28355034

  14. The biomechanical response of persons with transfemoral amputation to variations in prosthetic knee alignment during level walking.

    PubMed

    Koehler-McNicholas, Sara R; Lipschutz, Robert D; Gard, Steven A

    2016-01-01

    Prosthetic alignment is an important factor in the overall fit and performance of a lower-limb prosthesis. However, the association between prosthetic alignment and control strategies used by persons with transfemoral amputation to coordinate the movement of a passive prosthetic knee is poorly understood. This study investigated the biomechanical response of persons with transfemoral amputation to systematic perturbations in knee joint alignment during a level walking task. Quantitative gait data were collected for three alignment conditions: bench alignment, 2 cm anterior knee translation (ANT), and 2 cm posterior knee translation (POST). In response to a destabilizing alignment perturbation (i.e., the ANT condition), participants significantly increased their early-stance hip extension moment, confirming that persons with transfemoral amputation rely on a hip extensor strategy to maintain knee joint stability. However, participants also decreased the rate at which they loaded their prosthesis, decreased their affected-side step length, increased their trunk flexion, and maintained their prosthesis in a more vertical posture at the time of opposite toe off. Collectively, these results suggest that persons with transfemoral amputation rely on a combination of strategies to coordinate stance-phase knee flexion. Further, comparatively few significant changes were observed in response to the POST condition, suggesting that a bias toward posterior alignment may have fewer implications in terms of stance-phase, knee joint control.

  15. Joint Kinetics and Kinematics During Common Lower Limb Rehabilitation Exercises.

    PubMed

    Comfort, Paul; Jones, Paul Anthony; Smith, Laura Constance; Herrington, Lee

    2015-10-01

    Unilateral body-weight exercises are commonly used to strengthen the lower limbs during rehabilitation after injury, but data comparing the loading of the limbs during these tasks are limited. To compare joint kinetics and kinematics during 3 commonly used rehabilitation exercises. Descriptive laboratory study. Laboratory. A total of 9 men (age = 22.1 ± 1.3 years, height = 1.76 ± 0.08 m, mass = 80.1 ± 12.2 kg) participated. Participants performed the single-legged squat, forward lunge, and reverse lunge with kinetic data captured via 2 force plates and 3-dimensional kinematic data collected using a motion-capture system. Peak ground reaction forces, maximum joint angles, and peak sagittal-joint moments. We observed greater eccentric and concentric peak vertical ground reaction forces during the single-legged squat than during both lunge variations (P ≤ .001). Both lunge variations demonstrated greater knee and hip angles than did the single-legged squat (P < .001), but we observed no differences between lunges (P > .05). Greater dorsiflexion occurred during the single-legged squat than during both lunge variations (P < .05), but we noted no differences between lunge variations (P = .70). Hip-joint moments were greater during the forward lunge than during the reverse lunge (P = .003) and the single-legged squat (P = .011). Knee-joint moments were greater in the single-legged squat than in the reverse lunge (P < .001) but not greater in the single-legged squat than in the forward lunge (P = .41). Ankle-joint moments were greater during the single-legged squat than during the forward lunge (P = .002) and reverse lunge (P < .001). Appropriate loading progressions for the hip should begin with the single-legged squat and progress to the reverse lunge and then the forward lunge. In contrast, loading progressions for the knee and ankle should begin with the reverse lunge and progress to the forward lunge and then the single-legged squat.

  16. A biomechanical comparison of back and front squats in healthy trained individuals.

    PubMed

    Gullett, Jonathan C; Tillman, Mark D; Gutierrez, Gregory M; Chow, John W

    2009-01-01

    The strength and stability of the knee plays an integral role in athletics and activities of daily living. A better understanding of knee joint biomechanics while performing variations of the squat would be useful in rehabilitation and exercise prescription. We quantified and compared tibiofemoral joint kinetics as well as muscle activity while executing front and back squats. Because of the inherent change in the position of the center of mass of the bar between the front and back squat lifts, we hypothesized that the back squat would result in increased loads on the knee joint and that the front squat would result in increased knee extensor and decreased back extensor muscle activity. A crossover study design was used. To assess the net force and torque placed on the knee and muscle activation levels, a combination of video and force data, as well as surface electromyographic data, were collected from 15 healthy trained individuals. The back squat resulted in significantly higher compressive forces and knee extensor moments than the front squat. Shear forces at the knee were small in magnitude, posteriorly directed, and did not vary between the squat variations. Although bar position did not influence muscle activity, muscle activation during the ascending phase was significantly greater than during the descending phase. The front squat was as effective as the back squat in terms of overall muscle recruitment, with significantly less compressive forces and extensor moments. The results suggest that front squats may be advantageous compared with back squats for individuals with knee problems such as meniscus tears, and for long-term joint health.

  17. Analysis of Interrelationships among Voluntary and Prosthetic Leg Joint Parameters Using Cyclograms.

    PubMed

    Jasni, Farahiyah; Hamzaid, Nur Azah; Mohd Syah, Nor Elleeiana; Chung, Tze Y; Abu Osman, Noor Azuan

    2017-01-01

    The walking mechanism of a prosthetic leg user is a tightly coordinated movement of several joints and limb segments. The interaction among the voluntary and mechanical joints and segments requires particular biomechanical insight. This study aims to analyze the inter-relationship between amputees' voluntary and mechanical coupled leg joints variables using cyclograms. From this analysis, the critical gait parameters in each gait phase were determined and analyzed if they contribute to a better powered prosthetic knee control design. To develop the cyclogram model, 20 healthy able-bodied subjects and 25 prosthesis and orthosis users (10 transtibial amputees, 5 transfemoral amputees, and 10 different pathological profiles of orthosis users) walked at their comfortable speed in a 3D motion analysis lab setting. The gait parameters (i.e., angle, moment and power for the ankle, knee and hip joints) were coupled to form 36 cyclograms relationship. The model was validated by quantifying the gait disparities of all the pathological walking by analyzing each cyclograms pairs using feed-forward neural network with backpropagation. Subsequently, the cyclogram pairs that contributed to the highest gait disparity of each gait phase were manipulated by replacing it with normal values and re-analyzed. The manipulated cyclograms relationship that showed highest improvement in terms of gait disparity calculation suggested that they are the most dominant parameters in powered-knee control. In case of transfemoral amputee walking, it was identified using this approach that at each gait sub-phase, the knee variables most responsible for closest to normal walking were: knee power during loading response and mid-stance, knee moment and knee angle during terminal stance phase, knee angle and knee power during pre-swing, knee angle at initial swing, and knee power at terminal swing. No variable was dominant during mid-swing phase implying natural pendulum effect of the lower limb between the initial and terminal swing phases. The outcome of this cyclogram adoption approach proposed an insight into the method of determining the causal effect of manipulating a particular joint's mechanical properties toward the joint behavior in an amputee's gait by determining the curve closeness, C, of the modified cyclogram curve to the normal conventional curve, to enable quantitative judgment of the effect of changing a particular parameter in the prosthetic leg gait.

  18. Characterization of gait function in patients with postsurgical sagittal (flatback) deformity: a prospective study of 21 patients.

    PubMed

    Sarwahi, Vishal; Boachie-Adjei, Oheneba; Backus, Sherry I; Taira, Gaku

    2002-11-01

    This study prospectively analyzed gait in 21 patients with flatback and reviewed radiographs and charts. To analyze the effect of sagittal imbalance on gait and hip and knee joints. Loss of lumbar lordosis causes anterior displacement of the center of gravity, which creates instability and increases the work of gait. Several compensatory changes occur in response. The long-term effect of these changes on extra-axial joints has not been reported, nor have many studies analyzed the gait deviations in patients with flatback. Over time, as patients' ability to compensate is limited, increased gait deviations result. A total of 21 of 44 patients who had gait analysis as part of the preoperative workup were selected based on outlined criteria. Kinetics and kinematics data were analyzed along with radiographic and chart review. Normal healthy individuals served as controls. Gait deviations were present in gait kinetics and kinematics, including decreased stride length and velocity, to almost 60% of controls. Stance duration was prolonged with increased hip and knee flexion during stance. Hip and knee extensor moments were decreased with vertical ground reaction force showing slower rate of loading, reduced peak values, and flattening of normal loading response. Patients with flatback develop several compensatory mechanisms. The goal of the compensation is to maintain an efficient gait and decrease joint damage, but these safeguards fail over time. Flatback not only causes backache, abnormal posture, and abnormal body mechanics but also compromises the stability of gait and taxes the knee and hip joints adversely.

  19. Alterations in walking knee joint stiffness in individuals with knee osteoarthritis and self-reported knee instability.

    PubMed

    Gustafson, Jonathan A; Gorman, Shannon; Fitzgerald, G Kelley; Farrokhi, Shawn

    2016-01-01

    Increased walking knee joint stiffness has been reported in patients with knee osteoarthritis (OA) as a compensatory strategy to improve knee joint stability. However, presence of episodic self-reported knee instability in a large subgroup of patients with knee OA may be a sign of inadequate walking knee joint stiffness. The objective of this work was to evaluate the differences in walking knee joint stiffness in patients with knee OA with and without self-reported instability and examine the relationship between walking knee joint stiffness with quadriceps strength, knee joint laxity, and varus knee malalignment. Overground biomechanical data at a self-selected gait velocity was collected for 35 individuals with knee OA without self-reported instability (stable group) and 17 individuals with knee OA and episodic self-reported instability (unstable group). Knee joint stiffness was calculated during the weight-acceptance phase of gait as the change in the external knee joint moment divided by the change in the knee flexion angle. The unstable group walked with lower knee joint stiffness (p=0.01), mainly due to smaller heel-contact knee flexion angles (p<0.01) and greater knee flexion excursions (p<0.01) compared to their knee stable counterparts. No significant relationships were observed between walking knee joint stiffness and quadriceps strength, knee joint laxity or varus knee malalignment. Reduced walking knee joint stiffness appears to be associated with episodic knee instability and independent of quadriceps muscle weakness, knee joint laxity or varus malalignment. Further investigations of the temporal relationship between self-reported knee joint instability and walking knee joint stiffness are warranted. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Alterations in walking knee joint stiffness in individuals with knee osteoarthritis and self-reported knee instability

    PubMed Central

    Gustafson, Jonathan A.; Gorman, Shannon; Fitzgerald, G. Kelley; Farrokhi, Shawn

    2017-01-01

    Increased walking knee joint stiffness has been reported in patients with knee osteoarthritis (OA) as a compensatory strategy to improve knee joint stability. However, presence of episodic self-reported knee instability in a large subgroup of patients with knee OA may be a sign of inadequate walking knee joint stiffness. The objective of this work was to evaluate the differences in walking knee joint stiffness in patients with knee OA with and without self-reported instability and examine the relationship between walking knee joint stiffness with quadriceps strength, knee joint laxity, and varus knee malalignment. Overground biomechanical data at a self-selected gait velocity was collected for 35 individuals with knee OA without self-reported instability (stable group) and 17 individuals with knee OA and episodic self-reported instability (unstable group). Knee joint stiffness was calculated during the weight-acceptance phase of gait as the change in the external knee joint moment divided by the change in the knee flexion angle. The unstable group walked with lower knee joint stiffness (p=0.01), mainly due to smaller heel-contact knee flexion angles (p<0.01) and greater knee flexion excursions (p<0.01) compared to their knee stable counterparts. No significant relationships were observed between walking knee joint stiffness and quadriceps strength, knee joint laxity or varus knee malalignment. Reduced walking knee joint stiffness appears to be associated with episodic knee instability and independent of quadriceps muscle weakness, knee joint laxity or varus malalignment. Further investigations of the temporal relationship between self-reported knee joint instability and walking knee joint stiffness are warranted. PMID:26481256

  1. Definition and evaluation of testing scenarios for knee wear simulation under conditions of highly demanding daily activities.

    PubMed

    Schwiesau, Jens; Schilling, Carolin; Kaddick, Christian; Utzschneider, Sandra; Jansson, Volkmar; Fritz, Bernhard; Blömer, Wilhelm; Grupp, Thomas M

    2013-05-01

    The objective of our study was the definition of testing scenarios for knee wear simulation under various highly demanding daily activities of patients after total knee arthroplasty. This was mainly based on a review of published data on knee kinematics and kinetics followed by the evaluation of the accuracy and precision of a new experimental setup. We combined tibio-femoral load and kinematic data reported in the literature to develop deep squatting loading profiles for simulator input. A servo-hydraulic knee wear simulator was customised with a capability of a maximum flexion of 120°, a tibio-femoral load of 5000N, an anterior-posterior (AP) shear force of ±1000N and an internal-external (IE) rotational torque of ±50Nm to simulate highly demanding patient activities. During the evaluation of the newly configurated simulator the ability of the test machine to apply the required load and torque profiles and the flexion kinematics in a precise manner was examined by nominal-actual profile comparisons monitored periodically during subsequent knee wear simulation. For the flexion kinematics under displacement control a delayed actuator response of approximately 0.05s was inevitable due to the inertia of masses in movement of the coupled knee wear stations 1-3 during all applied activities. The axial load and IE torque is applied in an effective manner without substantial deviations between nominal and actual load and torque profiles. During the first third of the motion cycle a marked deviation between nominal and actual AP shear load profiles has to be noticed but without any expected measurable effect on the latter wear simulation due to the fact that the load values are well within the peak magnitude of the nominal load amplitude. In conclusion the described testing method will be an important tool to have more realistic knee wear simulations based on load conditions of the knee joint during activities of daily living. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  2. Joint loading decreased by inexpensive and minimalist footwear in elderly women with knee osteoarthritis during stair descent.

    PubMed

    Sacco, I C N; Trombini-Souza, F; Butugan, M K; Pássaro, A C; Arnone, A C; Fuller, R

    2012-03-01

    Previous studies indicate that flexible footwear, which mimics the biomechanics of walking barefoot, results in decreased knee loads in patients with knee osteoarthritis (OA) during walking. However, the effect of flexible footwear on other activities of daily living, such as descending stairs, remains unclear. Our objective was to evaluate the influence of inexpensive and minimalist footwear (Moleca) on knee adduction moment (KAM) during stair descent of elderly women with and without knee OA. Thirty-four elderly women were equally divided into an OA group and a control group (CG). Stair descent was evaluated in barefoot condition, while wearing the Moleca, and while wearing heeled shoes. Kinematics and ground reaction forces were measured to calculate KAM by using inverse dynamics. The OA group experienced a higher KAM during midstance under the barefoot condition (233.3%; P = 0.028), the Moleca (379.2%; P = 0.004), and heeled shoes (217.6%; P = 0.007). The OA group had a similar knee load during early, mid, and late stance with the Moleca compared with the barefoot condition. Heeled shoes increased the knee loads during the early-stance (versus barefoot [16.7%; P < 0.001] and versus the Moleca [15.5%; P < 0.001]), midstance (versus barefoot [8.6%; P = 0.014] and versus the Moleca [9.5%; P = 0.010]), and late-stance phase (versus barefoot [10.6%; P = 0.003] and versus the Moleca [9.2%; P < 0.001]). In the CG, the Moleca produced a knee load similar to the barefoot condition only during the early-stance phase. Besides the general foot protection, the inexpensive and minimalist footwear contributes to decreasing knee loads in elderly women with OA during stair descent. The loads are similar to the barefoot condition and effectively decreased when compared with heeled shoes. Copyright © 2012 by the American College of Rheumatology.

  3. Joint loads resulting in ACL rupture: Effects of age, sex, and body mass on injury load and mode of failure in a mouse model.

    PubMed

    Blaker, Carina L; Little, Christopher B; Clarke, Elizabeth C

    2017-08-01

    Anterior cruciate ligament (ACL) tears are a common knee injury with a known but poorly understood association with secondary joint injuries and post-traumatic osteoarthritis (OA). Female sex and age are known risk factors for ACL injury but these variables are rarely explored in mouse models of injury. This study aimed to further characterize a non-surgical ACL injury model to determine its clinical relevance across a wider range of mouse specifications. Cadaveric and anesthetized C57BL/6 mice (9-52 weeks of age) underwent joint loading to investigate the effects of age, sex, and body mass on ACL injury mechanisms. The ACL injury load (whole joint load required to rupture the ACL) was measured from force-displacement data, and mode of failure was assessed using micro-dissection and histology. ACL injury load was found to increase with body mass and age (p < 0.001) but age was not significant when controlling for mass. Sex had no effect. In contrast, the mode of ACL failure varied with both age and sex groups. Avulsion fractures (complete or mixed with mid-substance tears) were common in all age groups but the proportion of mixed and mid-substance failures increased with age. Females were more likely than males to have a major avulsion relative to a mid-substance tear (p < 0.01). This data compliments studies in human cadaveric knees, and provides a basis for determining the severity of joint injury relative to a major ACL tear in mice, and for selecting joint loading conditions in future experiments using this model. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1754-1763, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  4. Effects of barefoot and barefoot inspired footwear on knee and ankle loading during running.

    PubMed

    Sinclair, Jonathan

    2014-04-01

    Recreational runners frequently suffer from chronic pathologies. The knee and ankle have been highlighted as common injury sites. Barefoot and barefoot inspired footwear have been cited as treatment modalities for running injuries as opposed to more conventional running shoes. This investigation examined knee and ankle loading in barefoot and barefoot inspired footwear in relation to conventional running shoes. Thirty recreational male runners underwent 3D running analysis at 4.0m·s(-1). Joint moments, patellofemoral contact force and pressure and Achilles tendon forces were compared between footwear. At the knee the results show that barefoot and barefoot inspired footwear were associated with significant reductions in patellofemoral kinetic parameters. The ankle kinetics indicate that barefoot and barefoot inspired footwear were associated with significant increases in Achilles tendon force compared to conventional shoes. Barefoot and barefoot inspired footwear may serve to reduce the incidence of knee injuries in runners although corresponding increases in Achilles tendon loading may induce an injury risk at this tendon. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. In Vivo Knee Contact Force Prediction Using Patient-Specific Musculoskeletal Geometry in a Segment-Based Computational Model.

    PubMed

    Ding, Ziyun; Nolte, Daniel; Kit Tsang, Chui; Cleather, Daniel J; Kedgley, Angela E; Bull, Anthony M J

    2016-02-01

    Segment-based musculoskeletal models allow the prediction of muscle, ligament, and joint forces without making assumptions regarding joint degrees-of-freedom (DOF). The dataset published for the "Grand Challenge Competition to Predict in vivo Knee Loads" provides directly measured tibiofemoral contact forces for activities of daily living (ADL). For the Sixth Grand Challenge Competition to Predict in vivo Knee Loads, blinded results for "smooth" and "bouncy" gait trials were predicted using a customized patient-specific musculoskeletal model. For an unblinded comparison, the following modifications were made to improve the predictions: further customizations, including modifications to the knee center of rotation; reductions to the maximum allowable muscle forces to represent known loss of strength in knee arthroplasty patients; and a kinematic constraint to the hip joint to address the sensitivity of the segment-based approach to motion tracking artifact. For validation, the improved model was applied to normal gait, squat, and sit-to-stand for three subjects. Comparisons of the predictions with measured contact forces showed that segment-based musculoskeletal models using patient-specific input data can estimate tibiofemoral contact forces with root mean square errors (RMSEs) of 0.48-0.65 times body weight (BW) for normal gait trials. Comparisons between measured and predicted tibiofemoral contact forces yielded an average coefficient of determination of 0.81 and RMSEs of 0.46-1.01 times BW for squatting and 0.70-0.99 times BW for sit-to-stand tasks. This is comparable to the best validations in the literature using alternative models.

  6. A Patient-Specific Foot Model for the Estimate of Ankle Joint Forces in Patients with Juvenile Idiopathic Arthritis.

    PubMed

    Prinold, Joe A I; Mazzà, Claudia; Di Marco, Roberto; Hannah, Iain; Malattia, Clara; Magni-Manzoni, Silvia; Petrarca, Maurizio; Ronchetti, Anna B; Tanturri de Horatio, Laura; van Dijkhuizen, E H Pieter; Wesarg, Stefan; Viceconti, Marco

    2016-01-01

    Juvenile idiopathic arthritis (JIA) is the leading cause of childhood disability from a musculoskeletal disorder. It generally affects large joints such as the knee and the ankle, often causing structural damage. Different factors contribute to the damage onset, including altered joint loading and other mechanical factors, associated with pain and inflammation. The prediction of patients' joint loading can hence be a valuable tool in understanding the disease mechanisms involved in structural damage progression. A number of lower-limb musculoskeletal models have been proposed to analyse the hip and knee joints, but juvenile models of the foot are still lacking. This paper presents a modelling pipeline that allows the creation of juvenile patient-specific models starting from lower limb kinematics and foot and ankle MRI data. This pipeline has been applied to data from three children with JIA and the importance of patient-specific parameters and modelling assumptions has been tested in a sensitivity analysis focused on the variation of the joint reaction forces. This analysis highlighted the criticality of patient-specific definition of the ankle joint axes and location of the Achilles tendon insertions. Patient-specific detection of the Tibialis Anterior, Tibialis Posterior, and Peroneus Longus origins and insertions were also shown to be important.

  7. Center of mass trajectory and orientation to ankle and knee in sagittal plane is maintained with forward lean when backpack load changes during treadmill walking.

    PubMed

    Caron, Robert R; Wagenaar, Robert C; Lewis, Cara L; Saltzman, Elliot; Holt, Kenneth G

    2013-01-04

    Maintaining the normal shape and amplitude of the vertical trajectory of the center of mass (COM) during stance has been shown to maximize the efficiency of unloaded gait. Kinematic adaptations to load carriage, such as forward lean have yet to be understood in relation to COM movement. The purpose of this study is to better understand how load impacts the vertical COM(TSYS) trajectory and to clarify the impact of forward lean as it relates to the dynamics of sagittal plane COM(TSYS) movement during stance with changing load. 17 subjects walked on treadmill at a constant preferred walking velocity while nine different loads ranging from 12.5% to 40% bodyweight were systematically added and removed from a backpack. Kinematic data were collected using an Optotrak, three-dimensional motion analysis system and used to estimate position of the COM as well as segment and COM-to-joint vector orientation angles. The shape and amplitude of the COM vertical trajectory was maintained across all loaded conditions. The orientations of COM-to-ankle and -knee vectors were maintained in all loaded conditions except the heaviest load (40% BW). Results suggest that forward lean changed linearly with changes in load to maintain the COM-to-ankle and -knee vector orientations. COM vertical trajectory was maintained by a combination of invariants including lower-limb segment angles and a constant direction of toe-off impulse vector. The kinematic invariants found suggest a simplified control mechanism by which the system limits degrees of freedom and potentially minimizes torque about lower-extremity joints with added load. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Kinematics and muscle activity of the head, lumbar and knee joints during 180° turning and sitting down task in older adults.

    PubMed

    Kuo, Fang-Chuan; Hong, Chang-Zern; Liau, Ben-Yi

    2014-01-01

    The "180° turning and sitting down task" is a very conscious movement that requires focusing on turning at the exact moment, and very few studies address on this topic in older adults. The purpose of the study was to compare kinematics and electromyography of the head, lumbar and knee joints during 180°turning in older and young adults. Twenty older adults and 20 younger adults were assessed. A 16-channel telemetry electromyography system with electrogoniometers and an inclinometer were used to record the head, lumbar and knee joint kinematic and electromyography data during the 180° turning. This movement had been further divided into 4 phases (braking, mid-stance, swing, and terminal loading) for analysis. There were significant differences in the joint displacement and muscular activity among the different phases. Comparison between groups showed that the older adults group had less lateral lumbar flexion, less knee flexion and lower velocity of the head and knee flexion compared to young adults during turning. The electromyography data of the left biceps femoris, left gastrocnemius and left erector spinae muscles in the older adults group showed significantly higher levels than in the young adults. Older adults need to adjust velocities of moving joints and increase the extensor synergy muscles of the back and the stance leg to provide posture stability. Kinematics and neuromuscular modulations of the head, lumbar and knee are required according to the various phases of the turn movements and change with aging. © 2013.

  9. Long-term use of minimal footwear on pain, self-reported function, analgesic intake, and joint loading in elderly women with knee osteoarthritis: A randomized controlled trial.

    PubMed

    Trombini-Souza, Francis; Matias, Alessandra B; Yokota, Mariane; Butugan, Marco K; Goldenstein-Schainberg, Claudia; Fuller, Ricardo; Sacco, Isabel C N

    2015-12-01

    Efforts have been made to retard the progressive debilitating pain and joint dysfunction in patients with knee osteoarthritis. We aimed to evaluate the therapeutic effect of a low-cost minimalist footwear on pain, function, clinical and gait-biomechanical aspects of elderly women with knee osteoarthritis. Throughout a randomized, parallel and controlled clinical trial, fifty-six patients with medial knee osteoarthritis were randomly allocated to an intervention (n=28) or control group (n=28), and assessed at baseline and after three and six months. The intervention involved wearing Moleca(®) footwear for at least 6h/day, 7 days/week, over 6 months. The pain subscale of the Western Ontario and McMaster Universities Osteoarthritis Index was the primary outcome. The secondary outcomes were the other subscales, Lequesne score, distance walked in 6 min, knee oedema and effusion, knee adduction moment and paracetamol intake. Intention-to-treat analysis was performed using two-way casewise ANOVA (< .05) and Cohen's d coefficient. Intervention group showed improvement in pain (effect size: 1.41, p<.001), function (effect size: 1.22, p=.001), stiffness (effect size: 0.76, p=.001), Lequesne score (effect size: 1.07, p<.001), and reduction by 21.8% in the knee adduction moment impulse (p=.017) during gait wearing Moleca(®). The analgesic intake was lower in the intervention group. The long-term use of Moleca(®) footwear relieves pain, improves self-reported function, reduces the knee loading while wearing Moleca(®), refrains the increase of analgesic intake in elderly women with knee osteoarthritis and can be considered as a conservative mechanical treatment option. ClinicalTrials.gov (NCT01342458). Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Leg length discrepancy and osteoarthritis in the knee, hip and lumbar spine

    PubMed Central

    Murray, Kelvin J.; Azari, Michael F.

    2015-01-01

    Osteoarthritis (OA) is an extremely common condition that creates substantial personal and health care costs. An important recognised risk factor for OA is excessive or abnormal mechanical joint loading. Leg length discrepancy (LLD) is a common condition that results in uneven and excessive loading of not only knee joints but also hip joints and lumbar motion segments. Accurate imaging methods of LLD have made it possible to study the biomechanical effects of mild LLD (LLD of 20mm or less). This review examines the accuracy of these methods compared to clinical LLD measurements. It then examines the association between LLD and OA of the joints of the lower extremity. More importantly, it addresses the largely neglected association between LLD and degeneration of lumbar motion segments and the patterns of biomechanical changes that accompany LLD. We propose that mild LLD may be an important instigator or contributor to OA of the hip and lumbar spine, and that it deserves to be rigorously studied in order to decrease OA’s burden of disease. PMID:26500356

  11. Computational stability of human knee joint at early stance in Gait: Effects of muscle coactivity and anterior cruciate ligament deficiency.

    PubMed

    Sharifi, M; Shirazi-Adl, A; Marouane, H

    2017-10-03

    As one of the most complex and vulnerable structures of body, the human knee joint should maintain dynamic equilibrium and stability in occupational and recreational activities. The evaluation of its stability and factors affecting it is vital in performance evaluation/enhancement, injury prevention and treatment managements. Knee stability often manifests itself by pain, hypermobility and giving-way sensations and is usually assessed by the passive joint laxity tests. Mechanical stability of both the human knee joint and the lower extremity at early stance periods of gait (0% and 5%) were quantified here for the first time using a hybrid musculoskeletal model of the lower extremity. The roles of muscle coactivity, simulated by setting minimum muscle activation at 0-10% levels and ACL deficiency, simulated by reducing ACL resistance by up to 85%, on the stability margin as well as joint biomechanics (contact/muscle/ligament forces) were investigated. Dynamic stability was analyzed using both linear buckling and perturbation approaches at the final deformed configurations in gait. The knee joint was much more stable at 0% stance than at 5% due to smaller ground reaction and contact forces. Muscle coactivity, when at lower intensities (<3% of its maximum active force), increased dynamic stability margin. Greater minimum activation levels, however, acted asan ineffective strategy to enhance stability. Coactivation also substantially increased muscle forces, joint loads and ACL force and hence the risk of further injury and degeneration. A deficiency in ACL decreases total ACL force (by 31% at 85% reduced stiffness) and the stability margin of the knee joint at the heel strike. It also markedly diminishes forces in lateral hamstrings (by up to 39%) and contact forces on the lateral plateau (by up to 17%). Current work emphasizes the need for quantification of the lower extremity stability margin in gait. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Sex-based differences in lifting technique under increasing load conditions: A principal component analysis.

    PubMed

    Sheppard, P S; Stevenson, J M; Graham, R B

    2016-05-01

    The objective of the present study was to determine if there is a sex-based difference in lifting technique across increasing-load conditions. Eleven male and 14 female participants (n = 25) with no previous history of low back disorder participated in the study. Participants completed freestyle, symmetric lifts of a box with handles from the floor to a table positioned at 50% of their height for five trials under three load conditions (10%, 20%, and 30% of their individual maximum isometric back strength). Joint kinematic data for the ankle, knee, hip, and lumbar and thoracic spine were collected using a two-camera Optotrak motion capture system. Joint angles were calculated using a three-dimensional Euler rotation sequence. Principal component analysis (PCA) and single component reconstruction were applied to assess differences in lifting technique across the entire waveforms. Thirty-two PCs were retained from the five joints and three axes in accordance with the 90% trace criterion. Repeated-measures ANOVA with a mixed design revealed no significant effect of sex for any of the PCs. This is contrary to previous research that used discrete points on the lifting curve to analyze sex-based differences, but agrees with more recent research using more complex analysis techniques. There was a significant effect of load on lifting technique for five PCs of the lower limb (PC1 of ankle flexion, knee flexion, and knee adduction, as well as PC2 and PC3 of hip flexion) (p < 0.005). However, there was no significant effect of load on the thoracic and lumbar spine. It was concluded that when load is standardized to individual back strength characteristics, males and females adopted a similar lifting technique. In addition, as load increased male and female participants changed their lifting technique in a similar manner. Copyright © 2016. Published by Elsevier Ltd.

  13. Ground reaction forces and knee kinetics during single and repeated badminton lunges.

    PubMed

    Lam, Wing Kai; Ding, Rui; Qu, Yi

    2017-03-01

    Repeated movement (RM) lunge that frequently executed in badminton might be used for footwear evaluation. This study examined the influence of single movement (SM) and RM lunges on the ground reaction forces (GRFs) and knee kinetics during the braking phase of a badminton lunge step. Thirteen male university badminton players performed left-forward lunges in both SM and RM sessions. Force platform and motion capturing system were used to measure GRFs and knee kinetics variables. Paired t-test was performed to determine any significant differences between SM and RM lunges regarding mean and coefficient of variation (CV) in each variable. The kinetics results indicated that compared to SM lunges, the RM lunges had shorter contact time and generated smaller maximum loading rate of impact force, peak knee anterior-posterior force, and peak knee sagittal moment but generated larger peak horizontal resultant forces (Ps < 0.05). Additionally, the RM lunges had lower CV for peak knee medial-lateral and vertical forces (Ps < 0.05). These results suggested that the RM testing protocols had a distinct loading response and adaptation pattern during lunge and that the RM protocol showed higher within-trial reliability, which may be beneficial for the knee joint loading evaluation under different interventions.

  14. Identification and risk estimation of movement strategies during cutting maneuvers.

    PubMed

    David, Sina; Komnik, Igor; Peters, Markus; Funken, Johannes; Potthast, Wolfgang

    2017-12-01

    Approximately 70% of anterior cruciate ligament (ACL) injuries occur in non-contact situations during cutting and landing maneuvers. Parameters such as footstrike patterns and trunk orientation were found to influence ACL relevant knee loading, however, the relationship between the whole body movement and injury risk is debated. This study identifies whole body movement strategies that increase injury risk, and provides training recommendations to reduce this risk or enable a save return to sports after injury. Experimental cross-sectional study design. Three dimensional movement analysis was carried out to investigate 50 participants performing anticipated 90° cutting maneuvers. To identify and characterize movement strategies, footstrike pattern, knee valgus moment, knee internal rotation moment, angle of attack, shoulder and pelvis axis were analyzed using statistical parametric mapping. Three different movement strategies were identified. One strategy included rearfoot striking in combination with a relatively upright body position which generated higher knee joint loads than the second strategy, forefoot striking in combination with more backwards leaning and pre-rotation of the trunk towards the new movement direction. A third strategy combined forefoot striking with less preorientation which increased the ACL relevant knee joint load compared to the second strategy. The identified movement strategies clearly pre-determine the injury risk during non-contact situations with the third strategy as the most unfavorable one. Compared to the study of isolated parameters, the analysis of the whole body movement allowed for detailed separation of more risky from less risky cutting strategies. These results give practical recommendations for the prevention of ACL injury. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  15. Influence of footwear and equipment on stride length and range of motion of ankle, knee and hip joint.

    PubMed

    Schulze, Christoph; Lindner, Tobias; Woitge, Sandra; Schulz, Katharina; Finze, Susanne; Mittelmeier, Wolfram; Bader, Rainer

    2014-01-01

    Footwear and equipment worn by military personnel is of importance for them to be able to meet the physical demands specific to their profession daily activities. The aim of the present study was to investigate by means of gait analysis how army-provided footwear and equipment influence the range of motion of hip, knee and ankle joints as well as stride length. Thirty-two soldiers were subjected to gait analysis on a treadmill by way of video recordings and goniometric measurements. The stride length increased when military shoes are worn. We found no influence on stride length in connection to increased loading. The weight of the shoes represents the decisive factor. Neither shoes nor equipment changed the range of motion of the knee joint. Weight of equipment affected range of motion of the hip joint. The range of motion of the upper and lower ankle joints was mainly influenced by the properties of the shoes. Military footwear and weight of equipment influence stride length and range of motion of joints of the lower extremities in a specific way. Shape of material is the decisive factor.

  16. Applying Simulated In Vivo Motions to Measure Human Knee and ACL Kinetics

    PubMed Central

    Herfat, Safa T.; Boguszewski, Daniel V.; Shearn, Jason T.

    2013-01-01

    Patients frequently experience anterior cruciate ligament (ACL) injuries but current ACL reconstruction strategies do not restore the native biomechanics of the knee, which can contribute to the early onset of osteoarthritis in the long term. To design more effective treatments, investigators must first understand normal in vivo knee function for multiple activities of daily living (ADLs). While the 3D kinematics of the human knee have been measured for various ADLs, the 3D kinetics cannot be directly measured in vivo. Alternatively, the 3D kinetics of the knee and its structures can be measured in an animal model by simulating and applying subject-specific in vivo joint motions to a joint using robotics. However, a suitable biomechanical surrogate should first be established. This study was designed to apply a simulated human in vivo motion to human knees to measure the kinetics of the human knee and ACL. In pursuit of establishing a viable biomechanical surrogate, a simulated in vivo ovine motion was also applied to human knees to compare the loads produced by the human and ovine motions. The motions from the two species produced similar kinetics in the human knee and ACL. The only significant difference was the intact knee compression force produced by the two input motions. PMID:22227973

  17. Prosthetic knee design by simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hollerbach, K; Hollister, A

    1999-07-30

    Although 150,000 total knee replacement surgeries are performed annually in North America, current designs of knee prostheses have mechanical problems that include a limited range of motion, abnormal gait patterns, patellofemoral joint dysfunction, implant loosening or subsidence, and excessive wear. These problems fall into three categories: failure to reproduce normal joint kinematics, which results in altered limb function; bone-implant interface failure; and material failure. Modern computer technology can be used to design, prototype, and test new total knee implants. The design team uses the full range of CAD-CAM to design and produce implant prototypes for mechanical and clinical testing. Closermore » approximation of natural knee kinematics and kinetics is essential for improved patient function and diminished implant loads. Current knee replacement designs are based on 19th Century theories that the knee moves about a variable axis of rotation. Recent research has shown, however, that knee motion occurs about two fixed, offset axes of rotation. These aces are not perpendicular to the long axes of the bones or to each other, and the axes do not intersect. Bearing surfaces of mechanisms that move about axes of rotation are surfaces of revolution of those axes which advanced CAD technology can produce. Solids with surfaces of revolution for the two axes of rotation for the knee have been made using an HP9000 workstation and Structural Ideas Master Series CAD software at ArthroMotion. The implant's CAD model should closely replicate movements of the normal knee. The knee model will have a range of flexion-extension (FE) from -5 to 120 degrees. Movements include varus, valgus, internal and external rotation, as well as flexion and extension. The patellofemoral joint is aligned perpendicular to the FE axis and replicates the natural joint more closely than those of existing prostheses. The bearing surfaces will be more congruent than current designs and should generate lower stresses in the materials.« less

  18. The effects of a strength and neuromuscular exercise programme for the lower extremity on knee load, pain and function in obese children and adolescents: study protocol for a randomised controlled trial.

    PubMed

    Horsak, Brian; Artner, David; Baca, Arnold; Pobatschnig, Barbara; Greber-Platzer, Susanne; Nehrer, Stefan; Wondrasch, Barbara

    2015-12-23

    Childhood obesity is one of the most critical and accelerating health challenges throughout the world. It is a major risk factor for developing varus/valgus misalignments of the knee joint. The combination of misalignment at the knee and excess body mass may result in increased joint stresses and damage to articular cartilage. A training programme, which aims at developing a more neutral alignment of the trunk and lower limbs during movement tasks may be able to reduce knee loading during locomotion. Despite the large number of guidelines for muscle strength training and neuromuscular exercises that exist, most are not specifically designed to target the obese children and adolescent demographic. Therefore, the aim of this study is to evaluate a training programme which combines strength and neuromuscular exercises specifically designed to the needs and limitations of obese children and adolescents and analyse the effects of the training programme from a biomechanical and clinical point of view. A single assessor-blinded, pre-test and post-test randomised controlled trial, with one control and one intervention group will be conducted with 48 boys and girls aged between 10 and 18 years. Intervention group participants will receive a 12-week neuromuscular and quadriceps/hip strength training programme. Three-dimensional (3D) gait analyses during level walking and stair climbing will be performed at baseline and follow-up sessions. The primary outcome parameters for this study will be the overall peak external frontal knee moment and impulse during walking. Secondary outcomes include the subscales of the Knee injury and Osteoarthritis Outcome Score (KOOS), frontal and sagittal kinematics and kinetics for the lower extremities during walking and stair climbing, ratings of change in knee-related well-being, pain and function and adherence to the training programme. In addition, the training programme will be evaulated from a clinical and health status perspective by including the following analyses: cardiopulmonary testing to quantify aerobic fitness effects, anthropometric measures, nutritional status and psychological status to characterise the study sample. The findings will help to determine whether a neuromuscular and strength training exercise programme for the obese children population can reduce joint loading during locomotion, and thereby decrease the possible risk of developing degenerative joint diseases later in adulthood. ClinicalTrials NCT02545764 , Date of registration: 24 September 2015.

  19. A Better ARED Squat

    NASA Technical Reports Server (NTRS)

    Caldwell, E. E.; Newby, N. J.; Ploutz-Snyder, L.

    2014-01-01

    The 0-G ARED squat under loads the legs relative to the 1g ARED squat. In 1g the knee extensor/flexor muscles are primarily engaged due to the body's center of gravity is behind the knees during the motion of the squat. As body weight does not play a sufficient role 0 G, a crewmember's load exposure is limited by the load delivered by ARED through the exercise bar. Prescription loads for lowerbody resistance exercise in microgravity aim to include 1-G exercise bar load in addition to the crewmember's Earth body weight (BW); however, pressure points from the bar and the 1BW increased load at the shoulders translating to higher loads on the back have been a historical limitation for shoulders, requiring a decrease in exercise load at the start of the mission. Analogous to crewmembers, bed rest subjects report limitations of exercising with high loads on the back while performing squats on the horizontal exercise fixture (HEF), a custom exercise device that serves as an analog to 0-G ARED. Improvements for increasing loads on the HEF squat were suggested by distributing total exercise load between the hips and the bar1. The same is recommended for the 0-G ARED squat, with using current equipment on the ISS, which include the T2 running harness and T2 bungees. Quantification of this improvement has been accessed through computational modeling. The purpose of this study is to characterize joint torque during a squat with a distribution in exercise load on the ARED in 0 G. The analysis used existing models from NASA's Digital Astronaut Project. The biomechanics squat model was integrated with the ARED model and T2 bungees. The spring constant for the bungees were derived from ground testing. Forward dynamic simulation was performed for various conditions including anchor point attachments on the footplate of the ARED, bar load, hip load, and gravitational environment. The model confirms joint torques at knees is lower relative to 1G conditions primarily because the load delivery system is just with the exercise bar in 0 G. By distributing partial loads through use of the bungees to the hips joint-torque profiles were altered during a squat and provided options to enhance targeting lower-body loading in aims as for an improved countermeasure.

  20. Sound side joint contact forces in below knee amputee gait with an ESAR prosthetic foot.

    PubMed

    Karimi, Mohammad Taghi; Salami, Firooz; Esrafilian, Amir; Heitzmann, Daniel W W; Alimusaj, Merkur; Putz, Cornelia; Wolf, Sebastian I

    2017-10-01

    The incidence of knee and hip joint osteoarthritis in subjects with below knee amputation (BK) appears significantly higher compared to unimpaired subjects, especially in the intact side. However, it is controversial if constant higher loads on the sound side are one of the major factors for an increased osteoarthritis (OA) incidence in subjects with BK, beside other risk factors, e.g. with respect to metabolism. The aim wasto investigate joint contact forces (JCF) calculated by a musculoskeletal model in the intact side and to compare it with those of unimpaired subjects and to further elucidate in how far increased knee JCF are associated with increased frontal plane knee moments. A group of seven subjects with BK amputation and a group of ten unimpaired subjects were recruited for this study. Gait data were measured by 3D motion capture and force plates. OpenSim software was applied to calculate JCF. Maximum joint angles, ground reaction forces, and moments as well as time distance parameters were determined and compared between groups showing no significant differences, with some JCF components of knee and hip even being slightly smaller in subjects with BK compared to the reference group. This positive finding may be due to the selected ESAR foot. However, other beneficial factors may also have influenced this positive result such as the general good health status of the subjects or the thorough and proper fitting and alignment of the prosthesis. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Thirty Minutes of Running Exercise Decreases T2 Signal Intensity but Not Thickness of the Knee Joint Cartilage: A 3.0-T Magnetic Resonance Imaging Study.

    PubMed

    Karanfil, Yiğitcan; Babayeva, Naila; Dönmez, Gürhan; Diren, H Barış; Eryılmaz, Muzaffer; Doral, Mahmut Nedim; Korkusuz, Feza

    2018-04-01

    Objective Recent studies showed a potential of magnetic resonance imaging (MRI), which can be used as an additional tool for diagnosing cartilage degeneration in the early stage. We designed a cross-sectional study in order to evaluate knee joint cartilage adaptation to running, using 3.0-T MRI equipped with the 3-dimensional turbo spin echo (VISTA = Volume ISotropic Turbo spin echo Acquisition) software. By this thickness (mm) and signal intensity (mean pixel value) can be quantified, which could be closely related to the fluid content of the knee joint cartilage, before and after running. Methods A total of 22 males, aged 18 to 35 years, dominant (right) and nondominant (left) knees were assessed before and after 30 minutes of running. Cartilage thickness and signal intensity of surfaces of the patella, medial and lateral femoral and tibial condyles were measured. Results Cartilage thickness of the lateral condyle decreased at the dominant knee, while it increased at the medial tibial plateau. Signal intensity decreased at all locations, except the lateral patella in both knees. The most obvious decrease in signal intensity (10.6%) was at the medial tibial plateau from 949.8 to 849.0 of the dominant knee. Conclusion There was an increase in thickness measurements and decrease in signal intensity in medial tibial plateau of the dominant knee after 30 minutes of running. This outcome could be related to fluid outflow from the tissue. Greater reductions in the medial tibial plateau cartilage indicate greater load sharing by these areas of the joint during a 30-minute running.

  2. Standard versus physiologic bone preparation in total knee arthroplasty and the effect on joint space opening.

    PubMed

    Burkhart, Timothy A; Herman, Benjamin V; Perry, Kevin; Vandekerckhove, Pieter-Jan; Howard, James; Lanting, Brent

    2017-11-01

    Total knee arthroplasty is an effective treatment for osteoarthritis. Restoration of physiologic varus alignment may restore the native soft tissue tension and improve outcomes. Six paired fresh-frozen knee specimens were used to perform total knee arthroplastys. The left and right sides of were randomly assigned to have either a physiologic alignment cut or a standard of care neutral alignment bony cut prior to the implantation. Loads of 100 and 200N were applied at 0, 30, 60, and 90° of flexion and the magnitude of the medial and lateral compartment distraction was measured. The loads were applied with the knee specimen intact and post arthroplasty. The physiologic alignment had no difference between medial and lateral gaps at either load. With 100N of load the physiologic alignment had a greater gap at 90° than at full extension while the standard alignment had significantly more gap at 60° of flexion than full extension. The physiologic alignment had a significantly greater gap with the implant compared to the intact condition at both loads. The standard alignment had no significant difference in overall gap between the implant and intact condition with any load. Although performing a physiologic aligned TKA resulted in medial-lateral soft tissue balance, the flexion gap was found to have greater magnitude than the intact knee. Notably, a neutral aligned TKA was found to be balanced, but also was found to recreate the intact knee flexion gaps. These results suggest that coronal plane stability can be achieved with physiologic alignment objectives, but the clinician needs to be aware of the potential to have greater laxity than the intact and neutral alignment surgical objectives. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Knee joint kinematics and kinetics during the hop and cut after soft tissue artifact suppression: Time to reconsider ACL injury mechanisms?

    PubMed

    Smale, Kenneth B; Potvin, Brigitte M; Shourijeh, Mohammad S; Benoit, Daniel L

    2017-09-06

    The recent development of a soft tissue artifact (STA) suppression method allows us to re-evaluate the tibiofemoral kinematics currently linked to non-contact knee injuries. The purpose of this study was therefore to evaluate knee joint kinematics and kinetics in six degrees of freedom (DoF) during the loading phases of a jump lunge and side cut using this in silico method. Thirty-five healthy adults completed these movements and their surface marker trajectories were then scaled and processed with OpenSim's inverse kinematics (IK) and inverse dynamics tools. Knee flexion angle-dependent kinematic constraints defined based on previous bone pin (BP) marker trajectories were then applied to the OpenSim model during IK and these constrained results were then processed with the standard inverse dynamics tool. Significant differences for all hip, knee, and ankle DoF were observed after STA suppression for both the jump lunge and side cut. Using clinically relevant effect size estimates, we conclude that STA contamination had led to misclassifications in hip transverse plane angles, knee frontal and transverse plane angles, medial/lateral and distractive/compressive knee translations, and knee frontal plane moments between the NoBP and the BP IK solutions. Our results have substantial clinical implications since past research has used joint kinematics and kinetics contaminated by STA to identify risk factors for musculoskeletal injuries. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Wear simulation of total knee prostheses using load and kinematics waveforms from stair climbing.

    PubMed

    Abdel-Jaber, Sami; Belvedere, Claudio; Leardini, Alberto; Affatato, Saverio

    2015-11-05

    Knee wear simulators are meant to perform load cycles on knee implants under physiological conditions, matching exactly, if possible, those experienced at the replaced joint during daily living activities. Unfortunately, only conditions of low demanding level walking, specified in ISO-14243, are used conventionally during such tests. A recent study has provided a consistent knee kinematic and load data-set measured during stair climbing in patients implanted with a specific modern total knee prosthesis design. In the present study, wear simulation tests were performed for the first time using this data-set on the same prosthesis design. It was hypothesised that more demanding tasks would result in wear rates that differ from those observed in retrievals. Four prostheses for total knee arthroplasty were tested using a displacement-controlled knee wear simulator for two million cycles at 1.1 Hz, under kinematics and load conditions typical of stair climbing. After simulation, the corresponding damage scars on the bearings were qualified and compared with equivalent explanted prostheses. An average mass loss of 20.2±1.5 mg was found. Scanning digital microscopy revealed similar features, though the explant had a greater variety of damage modes, including a high prevalence of adhesive wear damage and burnishing in the overall articulating surface. This study confirmed that the results from wear simulation machines are strongly affected by kinematics and loads applied during simulations. Based on the present results for the full understanding of the current clinical failure of knee implants, a more comprehensive series of conditions are necessary for equivalent simulations in vitro. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Effects of toe-out and toe-in gait with varying walking speeds on knee joint mechanics and lower limb energetics.

    PubMed

    Khan, Soobia Saad; Khan, Saad Jawaid; Usman, Juliana

    2017-03-01

    Toe-out/-in gait has been prescribed in reducing knee joint load to medial knee osteoarthritis patients. This study focused on the effects of toe-out/-in at different walking speeds on first peak knee adduction moment (fKAM), second peak KAM (sKAM), knee adduction angular impulse (KAAI), net mechanical work by lower limb as well as joint-level contribution to the total limb work during level walking. Gait analysis of 20 healthy young adults was done walking at pre-defined normal (1.18m/s), slow (0.85m/s) and fast (1.43m/s) walking speeds with straight-toe (natural), toe-out (15°>natural) and toe-in (15°

  6. A systematic review and meta-analysis into the effect of lateral wedge arch support insoles for reducing knee joint load in patients with medial knee osteoarthritis.

    PubMed

    Xing, Fei; Lu, Bin; Kuang, Ming-Jie; Wang, Ying; Zhao, Yun-Long; Zhao, Jie; Sun, Lei; Wang, Yan; Ma, Jian-Xiong; Ma, Xin-Long

    2017-06-01

    The aim of this study was to evaluate the immediate effects of lateral wedge arch support insoles (LWAS) on reducing the knee joint load in patients with medial knee osteoarthritis (OA) compared with an appropriate control. Databases including Medline, EMBASE, Web of Science, Wiley Online Library, Cochrane library, and Google Scholar were searched with no limits on study date or language, from the earliest available date to October 31, 2016. The included studies had to have the aim of reducing knee load and have an appropriate control. The main measured values were the first and second peak external knee adduction moments (EKAM) and the knee adduction angular impulse (KAAI). The random-effects model was used for analyzing the eligible studies. Nine studies met the inclusion criteria with a total of 356 participants of whom 337 received LWAS treatment. The risk of methodological bias scores (quality index) ranged from 21 to 27 of 32. Treatment with LWAS resulted in statistically significant reductions in the first peak EKAM (P = .005), the second peak EKAM (P = .01), and the KAAI (P = .03). However, among trials in which the control treatment was control shoes, the LWAS showed no associations on the first peak EKAM (P = .10) or the KAAI (P =  .06); among trials in which the control treatment was neutral insoles, the LWAS showed no associations on the second peak EKAM (P = .21) or the KAAI (P = .23). At the same time, the LWAS showed no statistically significant reduction on the first peak EKAM (P = .39) when compared with flat insoles. Although meta-analysis outcomes of all studies indicated statistically significant associations between LWAS and reductions of the first peak EKAM, second peak EKAM and KAAI in people with medial knee OA while walking, different results existed in subgroups using various control conditions for comparison. These findings do not support the use of LWAS insoles for reducing knee load. An optimal LWAS treatment should provide the appropriate height of arch support and amount of lateral wedging. Further research should investigate the best combination of these 2 parameters to achieve efficacy without altered comfort.

  7. A systematic review and meta-analysis into the effect of lateral wedge arch support insoles for reducing knee joint load in patients with medial knee osteoarthritis

    PubMed Central

    Xing, Fei; Lu, Bin; Kuang, Ming-jie; Wang, Ying; Zhao, Yun-long; Zhao, Jie; Sun, Lei; Wang, Yan; Ma, Jian-xiong; Ma, Xin-long

    2017-01-01

    Abstract Objective: The aim of this study was to evaluate the immediate effects of lateral wedge arch support insoles (LWAS) on reducing the knee joint load in patients with medial knee osteoarthritis (OA) compared with an appropriate control. Methods: Databases including Medline, EMBASE, Web of Science, Wiley Online Library, Cochrane library, and Google Scholar were searched with no limits on study date or language, from the earliest available date to October 31, 2016. The included studies had to have the aim of reducing knee load and have an appropriate control. The main measured values were the first and second peak external knee adduction moments (EKAM) and the knee adduction angular impulse (KAAI). The random-effects model was used for analyzing the eligible studies. Results: Nine studies met the inclusion criteria with a total of 356 participants of whom 337 received LWAS treatment. The risk of methodological bias scores (quality index) ranged from 21 to 27 of 32. Treatment with LWAS resulted in statistically significant reductions in the first peak EKAM (P = .005), the second peak EKAM (P = .01), and the KAAI (P = .03). However, among trials in which the control treatment was control shoes, the LWAS showed no associations on the first peak EKAM (P = .10) or the KAAI (P =  .06); among trials in which the control treatment was neutral insoles, the LWAS showed no associations on the second peak EKAM (P = .21) or the KAAI (P = .23). At the same time, the LWAS showed no statistically significant reduction on the first peak EKAM (P = .39) when compared with flat insoles. Conclusion: Although meta-analysis outcomes of all studies indicated statistically significant associations between LWAS and reductions of the first peak EKAM, second peak EKAM and KAAI in people with medial knee OA while walking, different results existed in subgroups using various control conditions for comparison. These findings do not support the use of LWAS insoles for reducing knee load. An optimal LWAS treatment should provide the appropriate height of arch support and amount of lateral wedging. Further research should investigate the best combination of these 2 parameters to achieve efficacy without altered comfort. PMID:28614253

  8. Osteochondral microdamage from valgus bending of the human knee.

    PubMed

    Meyer, Eric G; Villwock, Mark R; Haut, Roger C

    2009-08-01

    Valgus bending of the knee is promoted as an anterior cruciate ligament injury mechanism and is associated with a characteristic "footprint" of bone bruising. The hypothesis of this study was that during ligamentous failure caused by valgus bending of the knee, high tibiofemoral contact pressures induce acute osteochondral microdamage. Four knee pairs were loaded in valgus bending until gross injury with or without a tibiofemoral compression pre-load. The peak valgus moment and resultant motions of the knee joint were recorded. Pressure sensitive film documented the magnitude and location of tibiofemoral contact. Cartilage fissures were documented on the tibial plateau, and microcracks in subchondral bone were documented from micro-computed tomography scans. Injuries were to the anterior cruciate ligament in three knees and the medial collateral ligament in seven knees. The mean (standard deviation) peak bending moment at failure was 107 (64)Nm. Valgus bending produced regions of contact on the lateral tibial plateau with average maximum pressures of approximately 30 (8)MPa. Cartilage fissures and subchondral bone microcracks were observed in these regions of high contact pressure. Combined valgus bending and tibiofemoral compression produce slightly higher contact pressures, but do not alter the gross injury pattern from isolated valgus bending experiments. Athletes who sustain a severe valgus knee bending moment, may be at risk of acute osteochondral damage especially if the loading mechanism occurs with a significant tibiofemoral compression component.

  9. [Study on the correlation between syndrome differ classification of knee osteoarthritis and X-ray image].

    PubMed

    Jin, Li-Kun; Zhang, Guo-Zhong; Tang, Ke; Liu, Yang

    2010-12-01

    To study the correlation between syndrome differ classification of knee osteoarthritis and X-ray image, so as to provide evidence for clinical diagnosis and treatment. From Jun. 2007 to Dec. 2007, 78 patients (108 knees) with knee osteoarthritis were reviewed, including 65 females (89 knees) and 13 males (19 knees), ranging in age from 41 to 77 years. According to the standards for the differentiation of syndrome in the treatment of knee osteoarthritis defined in Principle of Clinical Research for New Traditional Herbs, the patients were divided into three types: Type I, insufficiency of the liver and kidney, with stagnation of tendons and muscles, 43 knees; Type II, insufficiency of the spleen and kidney, with dampness infusion into bone and joints, 26 knees; Type I, deficiency of the liver and kidney, with inter-obstruction of phlegm and stasis 39 knees. Normotopia and lateral plain film of knee joint of weigh loading and in erect position, and patellofemoral Skyline plain flim was taken. Joint space narrow, osteophyte generation, subchondral osteosclerosis and subchondral cystic degeneration were evaluated. All data were analyzed by K independent samples nonparametric test in order to find out the correlation between syndrome differ classification of knee osteoarthritis and X-ray image. It was shown that after K independent samples nonparametric test about syndrome differ classification of knee osteoarthritis and X-ray image: there were significant differences among three types about lateral patella osteophyte, condyles of tibia osteophyte and Type II was the most serious, Type I was secondary, Type II was the lightest. Other index had no obvious difference among the three groups. There is certain correlation between syndrome differ classification of knee osteoarthritis and X-ray image. There are significant differences among three types about lateral patella osteophyte, condyles of tibia osteophyte, the Type II is the most serious,Type I is secondary, Type II is the lightest. Consequently, it can be deduced that worse osteophyte is one of accordances of Type II-insufficiency of the spleen and kidney, with dampness infusion into bone and joints. And, the Type II is more serious stage in radiologic manifestation.

  10. The Effect of Backpack Load Carriage on the Kinetics and Kinematics of Ankle and Knee Joints During Uphill Walking.

    PubMed

    Lee, Jinkyu; Yoon, Yong-Jin; Shin, Choongsoo S

    2017-12-01

    The purpose of this study was to investigate the effect of load carriage on the kinematics and kinetics of the ankle and knee joints during uphill walking, including joint work, range of motion (ROM), and stance time. Fourteen males walked at a self-selected speed on an uphill (15°) slope wearing military boots and carrying a rifle in hand without a backpack (control condition) and with a backpack. The results showed that the stance time significantly decreased with backpack carriage (p < .05). The mediolateral impulse significantly increased with backpack carriage (p < .05). In the ankle joints, the inversion-eversion, and dorsi-plantar flexion ROM in the ankle joints increased with backpack carriage (p < .05). The greater dorsi-plantar flexion ROM with backpack carriage suggested 1 strategy for obtaining high plantar flexor power during uphill walking. The result of the increased mediolateral impulse and inversion-eversion ROM in the ankle joints indicated an increase in body instability caused by an elevated center of mass with backpack carriage during uphill walking. The decreased stance time indicated that an increase in walking speed could be a compensatory mechanism for reducing the instability of the body during uphill walking while carrying a heavy backpack.

  11. Chain-loaded variable resistance warm-up improves free-weight maximal back squat performance.

    PubMed

    Mina, Minas A; Blazevich, Anthony J; Giakas, Giannis; Seitz, Laurent B; Kay, Anthony D

    2016-11-01

    The acute influence of chain-loaded variable resistance exercise on subsequent free-weight one-repetition maximum (1-RM) back squat performance was examined in 16 recreationally active men. The participants performed either a free-weight resistance (FWR) or chain-loaded resistance (CLR) back squat warm-up at 85% 1-RM on two separate occasions. After a 5-min rest, the participants attempted a free-weight 1-RM back squat; if successful, subsequent 5% load additions were made until participants failed to complete the lift. During the 1-RM trials, 3D knee joint kinematics and knee extensor and flexor electromyograms (EMG) were recorded simultaneously. Significantly greater 1-RM (6.2 ± 5.0%; p < .01) and mean eccentric knee extensor EMG (32.2 ± 6.7%; p < .01) were found after the CLR warm-up compared to the FWR condition. However, no difference (p > .05) was found in concentric EMG, eccentric or concentric knee angular velocity, or peak knee flexion angle. Performing a CLR warm-up enhanced subsequent free-weight 1-RM performance without changes in knee flexion angle or eccentric and concentric knee angular velocities; thus a real 1-RM increase was achieved as the mechanics of the lift were not altered. These results are indicative of a potentiating effect of CLR in a warm-up, which may benefit athletes in tasks where high-level strength is required.

  12. Effects of Two Football Stud Types on Knee and Ankle Kinetics of Single-Leg Land-Cut and 180° Cut Movements on Infilled Synthetic Turf.

    PubMed

    Bennett, Hunter J; Brock, Elizabeth; Brosnan, James T; Sorochan, John C; Zhang, Songning

    2015-10-01

    Higher ACL injury rates have been recorded in cleats with higher torsional resistance in American football, which warrants better understanding of shoe/stud-dependent joint kinetics. The purpose of this study was to determine differences in knee and ankle kinetics during single-leg land cuts and 180° cuts on synthetic infilled turf while wearing 3 types of shoes. Fourteen recreational football players performed single-leg land cuts and 180° cuts in nonstudded running shoes (RS) and in football shoes with natural (NTS) and synthetic turf studs (STS). Knee and ankle kinetic variables were analyzed with a 3 × 2 (shoe × movement) repeated-measures ANOVA (P < .05). A significant shoe-by-movement interaction was found in loading response peak knee adduction moments, with NTS producing smaller moments compared with both STS and RS only in 180° cuts. Reduced peak negative plantar flexor powers were also found in NTS compared with STS. The single-leg land cut produced greater loading response and push-off peak knee extensor moments, as well as peak negative and positive extensor and plantar flexor powers, but smaller loading peak knee adduction moments and push-off peak ankle eversion moments than 180° cuts. Overall, the STS and 180° cuts resulted in greater frontal plane knee loading and should be monitored for possible increased ACL injury risks.

  13. Knee and Hip Joint Kinematics Predict Quadriceps and Hamstrings Neuromuscular Activation Patterns in Drop Jump Landings

    PubMed Central

    Malfait, Bart; Dingenen, Bart; Smeets, Annemie; Staes, Filip; Pataky, Todd; Robinson, Mark A.; Vanrenterghem, Jos; Verschueren, Sabine

    2016-01-01

    Purpose The purpose was to assess if variation in sagittal plane landing kinematics is associated with variation in neuromuscular activation patterns of the quadriceps-hamstrings muscle groups during drop vertical jumps (DVJ). Methods Fifty female athletes performed three DVJ. The relationship between peak knee and hip flexion angles and the amplitude of four EMG vectors was investigated with trajectory-level canonical correlation analyses over the entire time period of the landing phase. EMG vectors consisted of the {vastus medialis(VM),vastus lateralis(VL)}, {vastus medialis(VM),hamstring medialis(HM)}, {hamstring medialis(HM),hamstring lateralis(HL)} and the {vastus lateralis(VL),hamstring lateralis(HL)}. To estimate the contribution of each individual muscle, linear regressions were also conducted using one-dimensional statistical parametric mapping. Results The peak knee flexion angle was significantly positively associated with the amplitudes of the {VM,HM} and {HM,HL} during the preparatory and initial contact phase and with the {VL,HL} vector during the peak loading phase (p<0.05). Small peak knee flexion angles were significantly associated with higher HM amplitudes during the preparatory and initial contact phase (p<0.001). The amplitudes of the {VM,VL} and {VL,HL} were significantly positively associated with the peak hip flexion angle during the peak loading phase (p<0.05). Small peak hip flexion angles were significantly associated with higher VL amplitudes during the peak loading phase (p = 0.001). Higher external knee abduction and flexion moments were found in participants landing with less flexed knee and hip joints (p<0.001). Conclusion This study demonstrated clear associations between neuromuscular activation patterns and landing kinematics in the sagittal plane during specific parts of the landing. These findings have indicated that an erect landing pattern, characterized by less hip and knee flexion, was significantly associated with an increased medial and posterior neuromuscular activation (dominant hamstrings medialis activity) during the preparatory and initial contact phase and an increased lateral neuromuscular activation (dominant vastus lateralis activity) during the peak loading phase. PMID:27101130

  14. Acute Effects of Foot Rotation in Healthy Adults during Running on Knee Moments and Lateral-Medial Shear Force

    PubMed Central

    Valenzuela, Kevin A.; Lynn, Scott K.; Noffal, Guillermo J.; Brown, Lee E.

    2016-01-01

    As runners age, the likelihood of developing osteoarthritis (OA) significantly increases as 10% of people 55+ have symptomatic knee OA while 70% of people 65+ have radiographic signs of knee OA. The lateral-medial shear force (LMF) and knee adduction moment (KAM) during gait have been associated with cartilage loading which can lead to OA. Foot rotation during gait has been shown to alter the LMF and KAM, however it has not been investigated in running. The purpose of this study was to investigate changes in the KAM and LMF with foot rotation during running. Twenty participants volunteered and performed five running trials in three randomized conditions (normal foot position [NORM], external rotation [EXT], and internal rotation [INT]) at a running speed of 3.35m·s-1 on a 20 meter runway. Kinematic and kinetic data were gathered using a 9-camera motion capture system and a force plate, respectively. Repeated measures ANOVAs determined differences between conditions. The KAM and LMF were lower in both EXT and INT conditions compared to the NORM, but there were no differences between EXT and INT conditions. The decreases in KAM and LMF in the EXT condition were expected and concur with past research in other activities. The reductions in the INT condition were unexpected and contradict the literature. This may indicate that participants are making mechanical compensations at other joints to reduce the KAM and LMF in this abnormal internal foot rotation condition. Key points External rotation of the foot during running reduced the loads on the medial compartment of the knee Internal rotation of the foot also reduced the medial loads, but is a more unnatural intervention External and internal rotation reduced the shear forces on the knee, which may help slow the degeneration of knee joint cartilage PMID:26957926

  15. The role of adipocytokines in the pathogenesis of knee joint osteoarthritis.

    PubMed

    Richter, Magdalena; Trzeciak, Tomasz; Owecki, Maciej; Pucher, Andrzej; Kaczmarczyk, Jacek

    2015-06-01

    Osteoarthritis (OA) is one of the most common causes of musculoskeletal disability in the world. Traditionally, it has been thought that obesity contributes to the development and progression of OA by increased mechanical load of the joint structures. Nevertheless, studies have shown that adipose tissue-derived cytokines (adipocytokines) are a possible link between obesity and OA. Furthermore, according to recent findings, not only articular cartilage may be the main target of these cytokines but also the synovial membrane, subchondral bone and infrapatellar fat pad may be encompassed in the process of degradation. This review presents the most recent reports on the contribution of adipocytokines to the knee joint cartilage degradation, osteophyte formation, infrapatellar fat pad alterations and synovitis.

  16. The effect of ankle bracing on knee kinetics and kinematics during volleyball-specific tasks.

    PubMed

    West, T; Ng, L; Campbell, A

    2014-12-01

    The purpose of this study was to examine the effects of ankle bracing on knee kinetics and kinematics during volleyball tasks. Fifteen healthy, elite, female volleyball players performed a series of straight-line and lateral volleyball tasks with no brace and when wearing an ankle brace. A 14-camera Vicon motion analysis system and AMTI force plate were used to capture the kinetic and kinematic data. Knee range of motion, peak knee anterior-posterior and medial-lateral shear forces, and peak ground reaction forces that occurred between initial contact with the force plate and toe off were compared using paired sample t-tests between the braced and non-braced conditions (P < 0.05). The results revealed no significant effect of bracing on knee kinematics or ground reaction forces during any task or on knee kinetics during the straight-line movement volleyball tasks. However, ankle bracing was demonstrated to reduce knee lateral shear forces during all of the lateral movement volleyball tasks. Wearing the Active Ankle T2 brace will not impact knee joint range of motion and may in fact reduce shear loading to the knee joint in volleyball players. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Electrical stimulation on joint contracture: an experiment in rat model with direct current.

    PubMed

    Akai, M; Shirasaki, Y; Tateishi, T

    1997-04-01

    To examine whether electrical stimulation could decrease the degree of joint stiffness in a rat lower extremity model. Rat knee joints were surgically immobilized in a flexed position for 3 weeks. Two groups of rats were stimulated with 20 microA and 50 microA constant direct current. Another group had surgical intervention and sham electrodes without electricity. The hind leg was extirpated and prepared for a sample with the femur-knee joint-tibia unit. Recording the knee flexion angle with extension torque, the degree of joint contracture was assessed biomechanically by measuring the bone-joint-bone sample as a cantilever. Measurement was performed with (1) spectral analysis of transfer function measurement using random mechanical noise with frequency range from 1 to 50Hz, and (2) dynamic stiffness and loss tangent with steady-state sinusoidal excitation (11 and 35Hz). The results showed that no significant difference or trend was found in vibration analysis among three groups. However, spectral analysis of transfer function measurement revealed more deformation against load, and more viscous nature in the stimulation groups, especially in low frequency band, than in the sham group. Electrical stimulation with constant direct current has a possibility of reducing the degree of joint contracture.

  18. Practical approach to subject-specific estimation of knee joint contact force.

    PubMed

    Knarr, Brian A; Higginson, Jill S

    2015-08-20

    Compressive forces experienced at the knee can significantly contribute to cartilage degeneration. Musculoskeletal models enable predictions of the internal forces experienced at the knee, but validation is often not possible, as experimental data detailing loading at the knee joint is limited. Recently available data reporting compressive knee force through direct measurement using instrumented total knee replacements offer a unique opportunity to evaluate the accuracy of models. Previous studies have highlighted the importance of subject-specificity in increasing the accuracy of model predictions; however, these techniques may be unrealistic outside of a research setting. Therefore, the goal of our work was to identify a practical approach for accurate prediction of tibiofemoral knee contact force (KCF). Four methods for prediction of knee contact force were compared: (1) standard static optimization, (2) uniform muscle coordination weighting, (3) subject-specific muscle coordination weighting and (4) subject-specific strength adjustments. Walking trials for three subjects with instrumented knee replacements were used to evaluate the accuracy of model predictions. Predictions utilizing subject-specific muscle coordination weighting yielded the best agreement with experimental data; however this method required in vivo data for weighting factor calibration. Including subject-specific strength adjustments improved models' predictions compared to standard static optimization, with errors in peak KCF less than 0.5 body weight for all subjects. Overall, combining clinical assessments of muscle strength with standard tools available in the OpenSim software package, such as inverse kinematics and static optimization, appears to be a practical method for predicting joint contact force that can be implemented for many applications. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Practical approach to subject-specific estimation of knee joint contact force

    PubMed Central

    Knarr, Brian A.; Higginson, Jill S.

    2015-01-01

    Compressive forces experienced at the knee can significantly contribute to cartilage degeneration. Musculoskeletal models enable predictions of the internal forces experienced at the knee, but validation is often not possible, as experimental data detailing loading at the knee joint is limited. Recently available data reporting compressive knee force through direct measurement using instrumented total knee replacements offer a unique opportunity to evaluate the accuracy of models. Previous studies have highlighted the importance of subject-specificity in increasing the accuracy of model predictions; however, these techniques may be unrealistic outside of a research setting. Therefore, the goal of our work was to identify a practical approach for accurate prediction of tibiofemoral knee contact force (KCF). Four methods for prediction of knee contact force were compared: (1) standard static optimization, (2) uniform muscle coordination weighting, (3) subject-specific muscle coordination weighting and (4) subject-specific strength adjustments. Walking trials for three subjects with instrumented knee replacements were used to evaluate the accuracy of model predictions. Predictions utilizing subject-specific muscle coordination weighting yielded the best agreement with experimental data, however this method required in vivo data for weighting factor calibration. Including subject-specific strength adjustments improved models’ predictions compared to standard static optimization, with errors in peak KCF less than 0.5 body weight for all subjects. Overall, combining clinical assessments of muscle strength with standard tools available in the OpenSim software package, such as inverse kinematics and static optimization, appears to be a practical method for predicting joint contact force that can be implemented for many applications. PMID:25952546

  20. Sensitivity of medial and lateral knee contact force predictions to frontal plane alignment and contact locations.

    PubMed

    Saliba, Christopher M; Brandon, Scott C E; Deluzio, Kevin J

    2017-05-24

    Musculoskeletal models are increasingly used to estimate medial and lateral knee contact forces, which are difficult to measure in vivo. The sensitivity of contact force predictions to modeling parameters is important to the interpretation and implication of results generated by the model. The purpose of this study was to quantify the sensitivity of knee contact force predictions to simultaneous errors in frontal plane knee alignment and contact locations under different dynamic conditions. We scaled a generic musculoskeletal model for N=23 subjects' stature and radiographic knee alignment, then perturbed frontal plane alignment and mediolateral contact locations within experimentally-possible ranges of 10° to -10° and 10 to -10mm, respectively. The sensitivity of first peak, second peak, and mean medial and lateral knee contact forces to knee adduction angle and contact locations was modeled using linear regression. Medial loads increased, and lateral loads decreased, by between 3% and 6% bodyweight for each degree of varus perturbation. Shifting the medial contact point medially increased medial loads and decreased lateral loads by between 1% and 4% bodyweight per millimeter. This study demonstrates that realistic measurement errors of 5mm (contact distance) or 5° (frontal plane alignment) could result in a combined 50% BW error in subject specific contact force estimates. We also show that model sensitivity varies between subjects as a result of differences in gait dynamics. These results demonstrate that predicted knee joint contact forces should be considered as a range of possible values determined by model uncertainty. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Progressive cell-mediated changes in articular cartilage and bone in mice are initiated by a single session of controlled cyclic compressive loading

    PubMed Central

    Ko, Frank C.; Dragomir, Cecilia L.; Plumb, Darren A.; Hsia, Allison W.; Adebayo, Olufunmilayo O.; Goldring, Steven R.; Wright, Timothy M.; Goldring, Mary B.; van der Meulen, Marjolein C.H.

    2017-01-01

    We previously showed that repetitive cyclic loading of the mouse knee joint causes changes that recapitulate the features of osteoarthritis (OA) in humans. By applying a single loading session, we characterized the temporal progression of the structural and compositional changes in subchondral bone and articular cartilage. We applied loading during a single 5-minute session to the left tibia of adult (26-week-old) C57Bl/6 male mice at a peak load of 9.0N for 1200 cycles. Knee joints were collected at times 0, 1, and 2 weeks after loading. The changes in articular cartilage and subchondral bone were analyzed by histology, immunohistochemistry (caspase-3 and cathepsin K), and microcomputed tomography. At time 0, no change was evident in chondrocyte viability or cartilage or subchondral bone integrity. However, cartilage pathology demonstrated by localized thinning and proteoglycan loss occurred at 1 and 2 weeks after the single session of loading. Transient cancellous bone loss was evident at 1 week, associated with increased osteoclast number. Bone loss was reversed to control levels at 2 weeks. We observed formation of fibrous and cartilaginous tissues at the joint margins at 1 and 2 weeks. Our findings demonstrate that a single session of noninvasive loading leads to the development of OA-like morphological and cellular alterations in articular cartilage and subchondral bone. The loss in subchondral trabecular bone mass and thickness returns to control levels at 2 weeks, whereas the cartilage thinning and proteoglycan loss persist. PMID:26896841

  2. Association of Soccer and Genu Varum in Adolescents

    PubMed Central

    Asadi, Kamran; Mirbolook, Ahmadreza; Heidarzadeh, Abtin; Mardani Kivi, Mohsen; Emami Meybodi, Mohammad Kazem; Rouhi Rad, Melina

    2015-01-01

    Background: Genu varum is a physical deformity marked by bowing of the leg. One of the risk factors of this musculoskeletal alignment is stress on the knee joint such as with exercise. Objectives: Since the evaluation of genu varum has not been widely studies, this study was conducted to examine the association between genu varum and playing soccer. Materials and Methods: Between Septembers 2010-2012, 750 soccer players and 750 non-soccer players 10-18 years of age were included in the study. A questionnaire of data including age, height, weight, body mass index (BMI), years of soccer participation, the average time of playing soccer per week, previous trauma to the lower limbs, history of any fractures of the knee, previous hospitalizations, and the distance of joint lines between the knees was assessed for all subjects. Chi-square, student t-test, and one-way ANOVA were used for statistical analysis by SPSS v.19.0 software. In all tests, a P value of less than 0.05 was construed as statistically significant. Results: Both soccer players and controls had genu varum. However, the incidence of genu varum was higher in the soccer players (P = 0.0001) and it was more prevalent in the 16-18 year age group (P = 0.0001). The results revealed a statistically significant association between the degree of practices and the prevalence of genu varum (P = 0.0001). Moreover, previous trauma to the knees and practicing in load-bearing sports led to an increase in the degree of genu varum (P = 0.0001). Conclusions: There was a higher incidence of genu varum in soccer players than in control adolescents; the stress and load imposed on the knee joint led to more severe genu varum. PMID:26290852

  3. Prediction of medial and lateral contact force of the knee joint during normal and turning gait after total knee replacement.

    PubMed

    Purevsuren, Tserenchimed; Dorj, Ariunzaya; Kim, Kyungsoo; Kim, Yoon Hyuk

    2016-04-01

    The computational modeling approach has commonly been used to predict knee joint contact forces, muscle forces, and ligament loads during activities of daily living. Knowledge of these forces has several potential applications, for example, within design of equipment to protect the knee joint from injury and to plan adequate rehabilitation protocols, although clinical applications of computational models are still evolving and one of the limiting factors is model validation. The objective of this study was to extend previous modeling technique and to improve the validity of the model prediction using publicly available data set of the fifth "Grand Challenge Competition to Predict In Vivo Knee Loads." A two-stage modeling approach, which combines conventional inverse dynamic analysis (the first stage) with a multi-body subject-specific lower limb model (the second stage), was used to calculate medial and lateral compartment contact forces. The validation was performed by direct comparison of model predictions and experimental measurement of medial and lateral compartment contact forces during normal and turning gait. The model predictions of both medial and lateral contact forces showed strong correlations with experimental measurements in normal gait (r = 0.75 and 0.71) and in turning gait trials (r = 0.86 and 0.72), even though the current technique over-estimated medial compartment contact forces in swing phase. The correlation coefficient, Sprague and Geers metrics, and root mean squared error indicated that the lateral contact forces were predicted better than medial contact forces in comparison with the experimental measurements during both normal and turning gait trials. © IMechE 2016.

  4. Rupture of posterior cruciate ligament leads to radial displacement of the medial meniscus.

    PubMed

    Zhang, Can; Deng, Zhenhan; Luo, Wei; Xiao, Wenfeng; Hu, Yihe; Liao, Zhan; Li, Kanghua; He, Hongbo

    2017-07-11

    To explore the association between the rupture of posterior cruciate ligament (PCL) and the radial displacement of medial meniscus under the conditions of different flexion and various axial loads. The radial displacement value of medial meniscus was measured for the specimens of normal adult knee joints, including 12 intact PCLs, 6 ruptures of the anterolateral bundle (ALB), 6 ruptures of the postmedial bundle (PMB), and 12 complete ruptures. The measurement was conducted at 0°, 30°, 60°, and 90° of knee flexion angles under 200 N, 400 N, 600 N, 800 N and 1000 N of axial loads respectively. The displacement values of medial meniscus of the ALB rupture group increased at 0° flexion under 800 N and 1000 N, and at 30°, 60° and 90° flexion under all loads in comparison with the PCL intact group. The displacement values of the PMB rupture group was higher at 0° and 90° flexion under all loads, and at 30° and 60° flexion under 800 N and 1000 N loads. The displacement of the PCL complete rupture group increased at all flexion angles under all loads. Either partial or complete rupture of the PCL can increase in the radial displacement of the medial meniscus, which may explain the degenerative changes that occuring in the medial meniscus due to PCL injury. Therefore, early reestablishment of the PCL is necessarily required in order to maintain stability of the knee joint after PCL injury.

  5. A new approach to implant alignment and ligament balancing in total knee arthroplasty focussing on joint loads.

    PubMed

    Zimmermann, Frauke; Schwenninger, Christoph; Nolten, Ulrich; Firmbach, Franz Peter; Elfring, Robert; Radermacher, Klaus

    2012-05-06

    Preservation and recovery of the mechanical leg axis as well as good rotational alignment of the prosthesis components and well-balanced ligaments are essential for the longevity of total knee arthroplasty (TKA). In the framework of the OrthoMIT project, the genALIGN system, a new navigated implantation approach based on intra-operative force-torque measurements, has been developed. With this system, optical or magnetic position tracking as well as any fixation of invasive rigid bodies are no longer necessary. For the alignment of the femoral component along the mechanical axis, a sensor-integrated instrument measures the torques resulting from the deviation between the instrument's axis and the mechanical axis under manually applied axial compression load. When both axes are coaxial, the resulting torques equal zero, and the tool axis can be fixed with respect to the bone. For ligament balancing and rotational alignment of the femoral component, the genALIGN system comprises a sensor-integrated tibial trial inlay measuring the amplitude and application points of the forces transferred between femur and tibia. Hereby, the impact of ligament tensions on knee joint loads can be determined over the whole range of motion. First studies with the genALIGN system, including a comparison with an imageless navigation system, show the feasibility of the concept.

  6. Using Cartilage MRI T2-Mapping to Analyze Early Cartilage Degeneration in the Knee Joint of Young Professional Soccer Players.

    PubMed

    Waldenmeier, Leonie; Evers, Christoph; Uder, Michael; Janka, Rolf; Hennig, Frank Friedrich; Pachowsky, Milena Liese; Welsch, Götz Hannes

    2018-02-01

    Objective To evaluate and characterize the appearance of articular cartilage in the tibiofemoral joint of young professional soccer players using T2-relaxation time evaluation on magnetic resonance imaging (MRI). Design In this study, we included 57 male adolescents from the youth academy of a professional soccer team. The MRI scans were acquired of the knee joint of the supporting leg. An "early unloading" (minute 0) and "late unloading" (minute 28) T2-sequence was included in the set of images. Quantitative T2-analysis was performed in the femorotibial joint cartilage in 4 slices with each 10 regions of interest (ROIs). Statistical evaluation, using Wilcoxon signed-rank tests, was primarily performed to compare the T2 values of the "early unloading" and "late unloading." Results When comparing "early unloading" with "late unloading," our findings showed a significant increase of T2-relaxation times in the weightbearing femoral cartilage of the medial ( P < 0.001) and lateral ( P < 0.001) compartment of the knee and in the tibial cartilage of the medial compartment ( P < 0.001). Conclusion In this study, alterations of the cartilage were found with a maximum in the medial condyle where the biomechanical load of the knee joint is highest, as well as where most of the chronic cartilage lesions occur. To avoid chronic damage, special focus should be laid on this region.

  7. Immediate effect of Masai Barefoot Technology shoes on knee joint moments in women with knee osteoarthritis.

    PubMed

    Tateuchi, Hiroshige; Taniguchi, Masashi; Takagi, Yui; Goto, Yusuke; Otsuka, Naoki; Koyama, Yumiko; Kobayashi, Masashi; Ichihashi, Noriaki

    2014-01-01

    Footwear modification can beneficially alter knee loading in patients with knee osteoarthritis. This study evaluated the effect of Masai Barefoot Technology shoes on reductions in external knee moments in patients with knee osteoarthritis. Three-dimensional motion analysis was used to examine the effect of Masai Barefoot Technology versus control shoes on the knee adduction and flexion moments in 17 women (mean age, 63.6 years) with radiographically confirmed knee osteoarthritis. The lateral and anterior trunk lean values, knee flexion and adduction angles, and ground reaction force were also evaluated. The influence of the original walking pattern on the changes in knee moments with Masai Barefoot Technology shoes was evaluated. The knee flexion moment in early stance was significantly reduced while walking with the Masai Barefoot Technology shoes (0.25±0.14Nm/kgm) as compared with walking with control shoes (0.30±0.19 Nm/kgm); whereas the knee adduction moment showed no changes. Masai Barefoot Technology shoes did not increase compensatory lateral and anterior trunk lean. The degree of knee flexion moment in the original walking pattern with control shoes was correlated directly with its reduction when wearing Masai Barefoot Technology shoes by multiple linear regression analysis (adjusted R2=0.44, P<0.01). Masai Barefoot Technology shoes reduced the knee flexion moment during walking without increasing the compensatory trunk lean and may therefore reduce external knee loading in women with knee osteoarthritis. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Loading Patterns of the Posterior Cruciate Ligament in the Healthy Knee: A Systematic Review

    PubMed Central

    List, Renate; Oberhofer, Katja; Fucentese, Sandro F.; Snedeker, Jess G.; Taylor, William R.

    2016-01-01

    Background The posterior cruciate ligament (PCL) is the strongest ligament of the knee, serving as one of the major passive stabilizers of the tibio-femoral joint. However, despite a number of experimental and modelling approaches to understand the kinematics and kinetics of the ligament, the normal loading conditions of the PCL and its functional bundles are still controversially discussed. Objectives This study aimed to generate science-based evidence for understanding the functional loading of the PCL, including the anterolateral and posteromedial bundles, in the healthy knee joint through systematic review and statistical analysis of the literature. Data sources MEDLINE, EMBASE and CENTRAL Eligibility criteria for selecting studies Databases were searched for articles containing any numerical strain or force data on the healthy PCL and its functional bundles. Studied activities were as follows: passive flexion, flexion under 100N and 134N posterior tibial load, walking, stair ascent and descent, body-weight squatting and forward lunge. Method Statistical analysis was performed on the reported load data, which was weighted according to the number of knees tested to extract average strain and force trends of the PCL and identify deviations from the norms. Results From the 3577 articles retrieved by the initial electronic search, only 66 met all inclusion criteria. The results obtained by aggregating data reported in the eligible studies indicate that the loading patterns of the PCL vary with activity type, knee flexion angle, but importantly also the technique used for assessment. Moreover, different fibres of the PCL exhibit different strain patterns during knee flexion, with higher strain magnitudes reported in the anterolateral bundle. While during passive flexion the posteromedial bundle is either lax or very slightly elongated, it experiences higher strain levels during forward lunge and has a synergetic relationship with the anterolateral bundle. The strain patterns obtained for virtual fibres that connect the origin and insertion of the bundles in a straight line show similar trends to those of the real bundles but with different magnitudes. Conclusion This review represents what is now the best available understanding of the biomechanics of the PCL, and may help to improve programs for injury prevention, diagnosis methods as well as reconstruction and rehabilitation techniques. PMID:27880849

  9. Comparison of loading rate-dependent injury modes in a murine model of post-traumatic osteoarthritis

    PubMed Central

    Lockwood, Kevin A.; Chu, Bryce T.; Anderson, Matthew J.; Haudenschild, Dominik R.; Christiansen, Blaine A.

    2014-01-01

    Post-traumatic osteoarthritis (PTOA) is a common long-term consequence of joint injuries such as anterior cruciate ligament (ACL) rupture. In this study we used a tibial compression overload mouse model to compare knee injury induced at low speed (1 mm/s), which creates an avulsion fracture, to injury induced at high speed (500 mm/s), which induces midsubstance tear of the ACL. Mice were sacrificed at 0 days, 10 days, 12 weeks, or 16 weeks post-injury, and joints were analyzed with micro-computed tomography, whole joint histology, and biomechanical laxity testing. Knee injury with both injury modes caused considerable trabecular bone loss by 10 days post-injury, with the Low Speed Injury group (avulsion) exhibiting a greater amount of bone loss than the High Speed Injury group (midsubstance tear). Immediately after injury, both injury modes resulted in greater than 2-fold increases in total AP joint laxity relative to control knees. By 12 and 16 weeks post-injury, total AP laxity was restored to uninjured control values, possibly due to knee stabilization via osteophyte formation. This model presents an opportunity to explore fundamental questions regarding the role of bone turnover in PTOA, and the findings of this study support a biomechanical mechanism of osteophyte formation following injury. PMID:24019199

  10. Predicting maximal strength of quadriceps from submaximal performance in individuals with knee joint osteoarthritis.

    PubMed

    McNair, Peter J; Colvin, Matt; Reid, Duncan

    2011-02-01

    To compare the accuracy of 12 maximal strength (1-repetition maximum [1-RM]) equations for predicting quadriceps strength in people with osteoarthritis (OA) of the knee joint. Eighteen subjects with OA of the knee joint attended a rehabilitation gymnasium on 3 occasions: 1) a familiarization session, 2) a session where the 1-RM of the quadriceps was established using a weights machine for an open-chain knee extension exercise and a leg press exercise, and 3) a session where the subjects performed with a load at which they could lift for approximately 10 repetitions only. The data were used in 12 prediction equations to calculate 1-RM strength and compared to the actual 1-RM data. Data were examined using Bland and Altman graphs and statistics, intraclass correlation coefficients (ICCs), and typical error values between the actual 1-RM and the respective 1-RM prediction equation data. Difference scores (predicted 1-RM--actual 1-RM) across the injured and control legs were also compared. For the knee extension exercise, the Brown, Brzycki, Epley, Lander, Mayhew et al, Poliquin, and Wathen prediction equations demonstrated the greatest levels of predictive accuracy. All of the ICCs were high (range 0.96–0.99), and typical errors were between 3% and 4%. For the knee press exercise, the Adams, Berger, Kemmler et al, and O'Conner et al equations demonstrated the greatest levels of predictive accuracy. All of the ICCs were high (range 0.95-0.98), and the typical errors ranged from 5.9-6.3%. This study provided evidence supporting the use of prediction equations to assess maximal strength in individuals with a knee joint with OA.

  11. Joint Kinetics and Kinematics During Common Lower Limb Rehabilitation Exercises

    PubMed Central

    Comfort, Paul; Jones, Paul Anthony; Smith, Laura Constance; Herrington, Lee

    2015-01-01

    Context  Unilateral body-weight exercises are commonly used to strengthen the lower limbs during rehabilitation after injury, but data comparing the loading of the limbs during these tasks are limited. Objective  To compare joint kinetics and kinematics during 3 commonly used rehabilitation exercises. Design  Descriptive laboratory study. Setting  Laboratory. Patients or Other Participants  A total of 9 men (age = 22.1 ± 1.3 years, height = 1.76 ± 0.08 m, mass = 80.1 ± 12.2 kg) participated. Intervention(s)  Participants performed the single-legged squat, forward lunge, and reverse lunge with kinetic data captured via 2 force plates and 3-dimensional kinematic data collected using a motion-capture system. Main Outcome Measure(s)  Peak ground reaction forces, maximum joint angles, and peak sagittal-joint moments. Results  We observed greater eccentric and concentric peak vertical ground reaction forces during the single-legged squat than during both lunge variations (P ≤ .001). Both lunge variations demonstrated greater knee and hip angles than did the single-legged squat (P < .001), but we observed no differences between lunges (P > .05). Greater dorsiflexion occurred during the single-legged squat than during both lunge variations (P < .05), but we noted no differences between lunge variations (P = .70). Hip-joint moments were greater during the forward lunge than during the reverse lunge (P = .003) and the single-legged squat (P = .011). Knee-joint moments were greater in the single-legged squat than in the reverse lunge (P < .001) but not greater in the single-legged squat than in the forward lunge (P = .41). Ankle-joint moments were greater during the single-legged squat than during the forward lunge (P = .002) and reverse lunge (P < .001). Conclusions  Appropriate loading progressions for the hip should begin with the single-legged squat and progress to the reverse lunge and then the forward lunge. In contrast, loading progressions for the knee and ankle should begin with the reverse lunge and progress to the forward lunge and then the single-legged squat. PMID:26418958

  12. Knee Cartilage Thickness, T1ρ and T2 Relaxation Time Are Related to Articular Cartilage Loading in Healthy Adults

    PubMed Central

    Van Rossom, Sam; Smith, Colin Robert; Zevenbergen, Lianne; Thelen, Darryl Gerard; Vanwanseele, Benedicte; Van Assche, Dieter; Jonkers, Ilse

    2017-01-01

    Cartilage is responsive to the loading imposed during cyclic routine activities. However, the local relation between cartilage in terms of thickness distribution and biochemical composition and the local contact pressure during walking has not been established. The objective of this study was to evaluate the relation between cartilage thickness, proteoglycan and collagen concentration in the knee joint and knee loading in terms of contact forces and pressure during walking. 3D gait analysis and MRI (3D-FSE, T1ρ relaxation time and T2 relaxation time sequence) of fifteen healthy subjects were acquired. Experimental gait data was processed using musculoskeletal modeling to calculate the contact forces, impulses and pressure distribution in the tibiofemoral joint. Correlates to local cartilage thickness and mean T1ρ and T2 relaxation times of the weight-bearing area of the femoral condyles were examined. Local thickness was significantly correlated with local pressure: medial thickness was correlated with medial condyle contact pressure and contact force, and lateral condyle thickness was correlated with lateral condyle contact pressure and contact force during stance. Furthermore, average T1ρ and T2 relaxation time correlated significantly with the peak contact forces and impulses. Increased T1ρ relaxation time correlated with increased shear loading, decreased T1ρ and T2 relaxation time correlated with increased compressive forces and pressures. Thicker cartilage was correlated with higher condylar loading during walking, suggesting that cartilage thickness is increased in those areas experiencing higher loading during a cyclic activity such as gait. Furthermore, the proteoglycan and collagen concentration and orientation derived from T1ρ and T2 relaxation measures were related to loading. PMID:28076431

  13. Dependence of muscle moment arms on in-vivo three-dimensional kinematics of the knee

    PubMed Central

    Navacchia, Alessandro; Kefala, Vasiliki; Shelburne, Kevin B.

    2016-01-01

    Quantification of muscle moment arms is important for clinical evaluation of muscle pathology and treatment, and for estimating muscle and joint forces in musculoskeletal models. Moment arms estimated with musculoskeletal models often assume a default motion of the knee derived from measurements of passive cadaveric flexion. However, knee kinematics are unique to each person and activity. The objective of this study was to estimate moment arms of the knee muscles with in vivo subject- and activity-specific kinematics from seven healthy subjects performing seated knee extension and single-leg lunge to show changes between subjects and activities. 3D knee motion was measured with a high-speed stereo-radiography system. Moment arms of ten muscles were estimated in OpenSim by replacing the default knee motion with in vivo measurements. Estimated inter-subject moment arm variability was similar to previously reported in vitro measurements. RMS deviations up to 9.0 mm (35.2% of peak value) were observed between moment arms estimated with subject-specific knee extension and passive cadaveric motion. The degrees of freedom that most impacted inter-activity differences were superior/inferior and anterior/posterior translations. Musculoskeletal simulations used to estimate in vivo muscle forces and joint loads may provide significantly different results when subject- and activity-specific kinematics are implemented. PMID:27620064

  14. Dependence of Muscle Moment Arms on In Vivo Three-Dimensional Kinematics of the Knee.

    PubMed

    Navacchia, Alessandro; Kefala, Vasiliki; Shelburne, Kevin B

    2017-03-01

    Quantification of muscle moment arms is important for clinical evaluation of muscle pathology and treatment, and for estimating muscle and joint forces in musculoskeletal models. Moment arms estimated with musculoskeletal models often assume a default motion of the knee derived from measurements of passive cadaveric flexion. However, knee kinematics are unique to each person and activity. The objective of this study was to estimate moment arms of the knee muscles with in vivo subject- and activity-specific kinematics from seven healthy subjects performing seated knee extension and single-leg lunge to show changes between subjects and activities. 3D knee motion was measured with a high-speed stereo-radiography system. Moment arms of ten muscles were estimated in OpenSim by replacing the default knee motion with in vivo measurements. Estimated inter-subject moment arm variability was similar to previously reported in vitro measurements. RMS deviations up to 9.0 mm (35.2% of peak value) were observed between moment arms estimated with subject-specific knee extension and passive cadaveric motion. The degrees of freedom that most impacted inter-activity differences were superior/inferior and anterior/posterior translations. Musculoskeletal simulations used to estimate in vivo muscle forces and joint loads may provide significantly different results when subject- and activity-specific kinematics are implemented.

  15. Simulating ideal assistive devices to reduce the metabolic cost of walking with heavy loads.

    PubMed

    Dembia, Christopher L; Silder, Amy; Uchida, Thomas K; Hicks, Jennifer L; Delp, Scott L

    2017-01-01

    Wearable robotic devices can restore and enhance mobility. There is growing interest in designing devices that reduce the metabolic cost of walking; however, designers lack guidelines for which joints to assist and when to provide the assistance. To help address this problem, we used musculoskeletal simulation to predict how hypothetical devices affect muscle activity and metabolic cost when walking with heavy loads. We explored 7 massless devices, each providing unrestricted torque at one degree of freedom in one direction (hip abduction, hip flexion, hip extension, knee flexion, knee extension, ankle plantarflexion, or ankle dorsiflexion). We used the Computed Muscle Control algorithm in OpenSim to find device torque profiles that minimized the sum of squared muscle activations while tracking measured kinematics of loaded walking without assistance. We then examined the metabolic savings provided by each device, the corresponding device torque profiles, and the resulting changes in muscle activity. We found that the hip flexion, knee flexion, and hip abduction devices provided greater metabolic savings than the ankle plantarflexion device. The hip abduction device had the greatest ratio of metabolic savings to peak instantaneous positive device power, suggesting that frontal-plane hip assistance may be an efficient way to reduce metabolic cost. Overall, the device torque profiles generally differed from the corresponding net joint moment generated by muscles without assistance, and occasionally exceeded the net joint moment to reduce muscle activity at other degrees of freedom. Many devices affected the activity of muscles elsewhere in the limb; for example, the hip flexion device affected muscles that span the ankle joint. Our results may help experimentalists decide which joint motions to target when building devices and can provide intuition for how devices may interact with the musculoskeletal system. The simulations are freely available online, allowing others to reproduce and extend our work.

  16. Simulating ideal assistive devices to reduce the metabolic cost of walking with heavy loads

    PubMed Central

    Silder, Amy; Uchida, Thomas K.; Hicks, Jennifer L.; Delp, Scott L.

    2017-01-01

    Wearable robotic devices can restore and enhance mobility. There is growing interest in designing devices that reduce the metabolic cost of walking; however, designers lack guidelines for which joints to assist and when to provide the assistance. To help address this problem, we used musculoskeletal simulation to predict how hypothetical devices affect muscle activity and metabolic cost when walking with heavy loads. We explored 7 massless devices, each providing unrestricted torque at one degree of freedom in one direction (hip abduction, hip flexion, hip extension, knee flexion, knee extension, ankle plantarflexion, or ankle dorsiflexion). We used the Computed Muscle Control algorithm in OpenSim to find device torque profiles that minimized the sum of squared muscle activations while tracking measured kinematics of loaded walking without assistance. We then examined the metabolic savings provided by each device, the corresponding device torque profiles, and the resulting changes in muscle activity. We found that the hip flexion, knee flexion, and hip abduction devices provided greater metabolic savings than the ankle plantarflexion device. The hip abduction device had the greatest ratio of metabolic savings to peak instantaneous positive device power, suggesting that frontal-plane hip assistance may be an efficient way to reduce metabolic cost. Overall, the device torque profiles generally differed from the corresponding net joint moment generated by muscles without assistance, and occasionally exceeded the net joint moment to reduce muscle activity at other degrees of freedom. Many devices affected the activity of muscles elsewhere in the limb; for example, the hip flexion device affected muscles that span the ankle joint. Our results may help experimentalists decide which joint motions to target when building devices and can provide intuition for how devices may interact with the musculoskeletal system. The simulations are freely available online, allowing others to reproduce and extend our work. PMID:28700630

  17. 21 CFR 888.3570 - Knee joint femoral (hemi-knee) metallic uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femoral (hemi-knee) metallic uncemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3570 Knee joint femoral (hemi-knee) metallic uncemented prosthesis. (a) Identification. A knee joint femoral (hemi-knee...

  18. Three-dimensional knee motion before and after high tibial osteotomy for medial knee osteoarthritis.

    PubMed

    Takemae, Takashi; Omori, Go; Nishino, Katsutoshi; Terajima, Kazuhiro; Koga, Yoshio; Endo, Naoto

    2006-11-01

    High tibial osteotomy (HTO) is an established surgical option for treating medial knee osteoarthritis. HTO moves the mechanical load on the knee joint from the medial compartment to the lateral compartment by changing the leg alignment, but the effects of the operation remain unclear. The purpose of this study was to evaluate the change in three-dimensional knee motion before and after HTO, focusing on lateral thrust and screw home movement, and to investigate the relationship between the change in knee motion and the clinical results. A series of 19 patients with medial knee osteoarthritis who had undergone HTO were evaluated. We performed a clinical assessment, radiological evaluation, and motion analysis at 2.4 years postoperatively. The clinical assessment was performed using the Japanese Orthopaedic Association knee score. The score was significantly improved in all patients after operation. Motion analysis revealed that lateral thrust, which was observed in 18 of the 20 knees before operation, was reduced to 7 knees after operation. Regarding active terminal extension of the knee, three patterns of rotational movement were observed before operation: screw home movement (external rotation), reverse screw home movement (internal rotation), and no rotation. By contrast, after operation, only reverse screw home movement and no rotation were observed; the screw home movement disappeared in all patients. In the knees with reverse screw home movement after operation, the preoperative score was significantly lower than those in the knees with no rotation after operation. Kinetically, HTO was useful for suppressing lateral thrust in medial knee osteoarthritis, although the rotational movement of the knee joint was unchanged.

  19. Quantification of effect of sequential posteromedial release on flexion and extension gaps: a computer-assisted study in cadaveric knees.

    PubMed

    Mullaji, Arun; Sharma, Amit; Marawar, Satyajit; Kanna, Raj

    2009-08-01

    A novel sequence of posteromedial release consistent with surgical technique of total knee arthroplasty was performed in 15 cadaveric knees. Medial and lateral flexion and extension gaps were measured after each step of the release using a computed tomography-free computer navigation system. A spring-loaded distractor and a manual distractor were used to distract the joint. Posterior cruciate ligament release increased flexion more than extension gap; deep medial collateral ligament release had a negligible effect; semimembranosus release increased the flexion gap medially; reduction osteotomy increased medial flexion and extension gaps; superficial medial collateral ligament release increased medial joint gap more in flexion and caused severe instability. This sequence of release led to incremental and differential effects on flexion-extension gaps and has implications in correcting varus deformity.

  20. 21 CFR 888.3590 - Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint tibial (hemi-knee) metallic resurfacing... Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis is a device intended to be implanted...

  1. 21 CFR 888.3580 - Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellar (hemi-knee) metallic... § 888.3580 Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis is a device made of...

  2. Altered Frontal and Transverse Plane Tibiofemoral Kinematics and Patellofemoral Malalignments During Downhill Gait in Patients with Mixed Knee Osteoarthritis

    PubMed Central

    Farrokhi, Shawn; Meholic, Brad; Chuang, Wei-Neng; Gustafson, Jonathan A.; Fitzgerald, G. Kelley; Tashman, Scott

    2015-01-01

    Patients with knee osteoarthritis often present with signs of mixed tibiofemoral and patellofemoral joint disease. It has been suggested that altered frontal and transverse plane knee joint mechanics play a key role in compartment-specific patterns of knee osteoarthritis, but invivo evidence in support of this premise remains limited. Using Dynamic Stereo X-ray techniques, the aim of this study was to compare the frontal and transverse plane tibiofemoral kinematics and patellofemoral malalignments during the loading response phase of downhill gait in three groups of older adults: patients with medial tibiofemoral compartment and coexisting patellofemoral osteoarthritis (n=11); patients with lateral tibiofemoral compartment and coexisting patellofemoral osteoarthritis (n=10); and an osteoarthritis-free control group (n=22). Patients with lateral compartment osteoarthritis walked with greater and increasing degrees of tibiofemoral abduction compared to the medial compartment osteoarthritis and the control groups who walked with increasing degrees of tibiofemoral adduction. Additionally, the medial and lateral compartment osteoarthritis groups demonstrated reduced degrees of tibiofemoral internal rotation compared to the control group. Both medial and lateral compartment osteoarthritis groups also walked with increasing degrees of lateral patella tilt and medial patella translation during the loading response phase of downhill gait. Our findings suggest that despite the differences in frontal and transverse plane tibiofemoral kinematics between patients with medial and lateral compartment osteoarthritis, the malalignments of their arthritic patellofemoral joint appears to be similar. Further research is needed to determine if these kinematic variations are relevant targets for interventions to reduce pain and disease progression in patients with mixed disease. PMID:26087880

  3. Modulation of the relationship between external knee adduction moments and medial joint contact forces across subjects and activities.

    PubMed

    Trepczynski, Adam; Kutzner, Ines; Bergmann, Georg; Taylor, William R; Heller, Markus O

    2014-05-01

    The external knee adduction moment (EAM) is often considered a surrogate measure of the distribution of loads across the tibiofemoral joint during walking. This study was undertaken to quantify the relationship between the EAM and directly measured medial tibiofemoral contact forces (Fmed ) in a sample of subjects across a spectrum of activities. The EAM for 9 patients who underwent total knee replacement was calculated using inverse dynamics analysis, while telemetric implants provided Fmed for multiple repetitions of 10 activities, including walking, stair negotiation, sit-to-stand activities, and squatting. The effects of the factors "subject" and "activity" on the relationships between Fmed and EAM were quantified using mixed-effects regression analyses in terms of the root mean square error (RMSE) and the slope of the regression. Across subjects and activities a good correlation between peak EAM and Fmed values was observed, with an overall R(2) value of 0.88. However, the slope of the linear regressions varied between subjects by up to a factor of 2. At peak EAM and Fmed , the RMSE of the regression across all subjects was 35% body weight (%BW), while the maximum error was 127 %BW. The relationship between EAM and Fmed is generally good but varies considerably across subjects and activities. These findings emphasize the limitation of relying solely on the EAM to infer medial joint loading when excessive directed cocontraction of muscles exists and call for further investigations into the soft tissue-related mechanisms that modulate the internal forces at the knee. Copyright © 2014 by the American College of Rheumatology.

  4. Habitual Minimalist Shod Running Biomechanics and the Acute Response to Running Barefoot.

    PubMed

    Tam, Nicholas; Darragh, Ian A J; Divekar, Nikhil V; Lamberts, Robert P

    2017-09-01

    The aim of the study was to determine whether habitual minimalist shoe runners present with purported favorable running biomechanithat reduce running injury risk such as initial loading rate. Eighteen minimalist and 16 traditionally cushioned shod runners were assessed when running both in their preferred training shoe and barefoot. Ankle and knee joint kinetics and kinematics, initial rate of loading, and footstrike angle were measured. Sagittal ankle and knee joint stiffness were also calculated. Results of a two-factor ANOVA presented no group difference in initial rate of loading when participants were running either shod or barefoot; however, initial loading rate increased for both groups when running barefoot (p=0.008). Differences in footstrike angle were observed between groups when running shod, but not when barefoot (minimalist:8.71±8.99 vs. traditional: 17.32±11.48 degrees, p=0.002). Lower ankle joint stiffness was found in both groups when running barefoot (p=0.025). These findings illustrate that risk factors for injury potentially differ between the two groups. Shoe construction differences do change mechanical demands, however, once habituated to the demands of a given shoe condition, certain acute favorable or unfavorable responses may be moderated. The purported benefits of minimalist running shoes in mimicking habitual barefoot running is questioned, and risk of injury may not be attenuated. © Georg Thieme Verlag KG Stuttgart · New York.

  5. Staphylococcus aureus-dependent septic arthritis in murine knee joints: local immune response and beneficial effects of vaccination

    PubMed Central

    Corrado, Alessia; Donato, Paolo; Maccari, Silvia; Cecchi, Raffaella; Spadafina, Tiziana; Arcidiacono, Letizia; Tavarini, Simona; Sammicheli, Chiara; Laera, Donatello; Manetti, Andrea Guido Oreste; Ruggiero, Paolo; Galletti, Bruno; Nuti, Sandra; De Gregorio, Ennio; Bertholet, Sylvie; Seubert, Anja; Bagnoli, Fabio; Bensi, Giuliano; Chiarot, Emiliano

    2016-01-01

    Staphylococcus aureus is the major cause of human septic arthritis and osteomyelitis, which deserve special attention due to their rapid evolution and resistance to treatment. The progression of the disease depends on both bacterial presence in situ and uncontrolled disruptive immune response, which is responsible for chronic disease. Articular and bone infections are often the result of blood bacteremia, with the knees and hips being the most frequently infected joints showing the worst clinical outcome. We report the development of a hematogenous model of septic arthritis in murine knees, which progresses from an acute to a chronic phase, similarly to what occurs in humans. Characterization of the local and systemic inflammatory and immune responses following bacterial infection brought to light specific signatures of disease. Immunization of mice with the vaccine formulation we have recently described (4C-Staph), induced a strong antibody response and specific CD4+ effector memory T cells, and resulted in reduced bacterial load in the knee joints, a milder general inflammatory state and protection against bacterial-mediated cellular toxicity. Possible correlates of protection are finally proposed, which might contribute to the development of an effective vaccine for human use. PMID:27901071

  6. The relationship between quadriceps muscle force, knee flexion, and anterior cruciate ligament strain in an in vitro simulated jump landing.

    PubMed

    Withrow, Thomas J; Huston, Laura J; Wojtys, Edward M; Ashton-Miller, James A

    2006-02-01

    An instrumented cadaveric knee construct was used to quantify the association between impact force, quadriceps force, knee flexion angle, and anterior cruciate ligament relative strain in simulated unipedal jump landings. Anterior cruciate ligament strain will correlate with impact force, quadriceps force, and knee flexion angle. Descriptive laboratory study. Eleven cadaveric knees (age, 70.8 [19.3] years; 5 male; 6 female) were mounted in a custom fixture with the tibia and femur secured to a triaxial load cell. Quadriceps, hamstring, and gastrocnemius muscle forces were simulated using pretensioned steel cables (stiffness, 7 kN/cm), and the quadriceps tendon force was measured using a load cell. Mean strain on the anteromedial bundle of the anterior cruciate ligament was measured using a DVRT. With the knee in 25 degrees of flexion, the construct was vertically loaded by an impact force initially directed 4 cm posterior to the knee joint center. Tibiofemoral kinematics was measured using a 3D optoelectronic tracking system. The increase in anterior cruciate ligament relative strain was proportional to the increase in quadriceps force (r(2) = 0.74; P < .00001) and knee flexion angle (r(2) = 0.88; P < .00001) but was not correlated with the impact force (r(2) = 0.009; P = .08). The increase in knee flexion and quadriceps force during this simulated 1-footed landing strongly influenced the relative strain on the anteromedial bundle of the anterior cruciate ligament. These results suggest that even in the presence of knee flexor muscle forces, the increase in quadriceps force required to prevent the knee from flexing during landing can place the anterior cruciate ligament at risk for large strains.

  7. A Computational Modeling Approach for Investigating Soft Tissue Balancing in Bicruciate Retaining Knee Arthroplasty

    PubMed Central

    Amiri, Shahram; Wilson, David R.

    2012-01-01

    Bicruciate retaining knee arthroplasty, although has shown improved functions and patient satisfaction compared to other designs of total knee replacement, remains a technically demanding option for treating severe cases of arthritic knees. One of the main challenges in bicruciate retaining arthroplasty is proper balancing of the soft tissue during the surgery. In this study biomechanics of soft tissue balancing was investigated using a validated computational model of the knee joint with high fidelity definitions of the soft tissue structures along with a Taguchi method for design of experiments. The model was used to simulate intraoperative balancing of soft tissue structures following the combinations suggested by an orthogonal array design. The results were used to quantify the corresponding effects on the laxity of the joint under anterior-posterior, internal-external, and varus-valgus loads. These effects were ranked for each ligament bundle to identify the components of laxity which were most sensitive to the corresponding surgical modifications. The resulting map of sensitivity for all the ligament bundles determined the components of laxity most suitable for examination during intraoperative balancing of the soft tissue. Ultimately, a sequence for intraoperative soft tissue balancing was suggested for a bicruciate retaining knee arthroplasty. PMID:23082090

  8. Patellar tendon load in different types of eccentric squats.

    PubMed

    Frohm, A; Halvorsen, K; Thorstensson, A

    2007-07-01

    Differences in mechanical loading of the patellar tendon have been suggested as a reason for varying effects in rehabilitation of patellar tendinopathy using different eccentric squat exercises and devices. The aim was to characterize the magnitude and pattern of mechanical load at the knee and on the patellar tendon during four types of eccentric squat. Subjects performed squats with a submaximal free weight and with maximal effort in a device for eccentric overloading (Bromsman), on a decline board and horizontal surface. Kinematics was recorded with a motion-capture system, reaction forces with force plates, and electromyography from three leg muscles with surface electrodes. Inverse dynamics was used to calculate knee joint kinetics. Eccentric work, mean and peak patellar tendon force, and angle at peak force were greater (25-30%) for squats on decline board compared to horizontal surface with free weight, but not in Bromsman. Higher knee load forces (60-80%), but not work, were observed with Bromsman than free weight. Angular excursions at the knee and ankle were larger with decline board, particularly with free weight, and smaller in Bromsman than with free weight. Mean electromyography was greater on a decline board for gastrocnemius (13%) and vastus medialis (6%) with free weight, but in Bromsman only for gastrocnemius (7%). The results demonstrated clear differences in the biomechanical loading on the knee during different squat exercises. Quantification of such differences provides information that could be used to explain differences in rehabilitation effects as well as in designing more optimal rehabilitation exercises for patellar tendinopathy.

  9. Deformation of articular cartilage during static loading of a knee joint--experimental and finite element analysis.

    PubMed

    Halonen, K S; Mononen, M E; Jurvelin, J S; Töyräs, J; Salo, J; Korhonen, R K

    2014-07-18

    Novel conical beam CT-scanners offer high resolution imaging of knee structures with i.a. contrast media, even under weight bearing. With this new technology, we aimed to determine cartilage strains and meniscal movement in a human knee at 0, 1, 5, and 30 min of standing and compare them to the subject-specific 3D finite element (FE) model. The FE model of the volunteer׳s knee, based on the geometry obtained from magnetic resonance images, was created to simulate the creep. The effects of collagen fibril network stiffness, nonfibrillar matrix modulus, permeability and fluid flow boundary conditions on the creep response in cartilage were investigated. In the experiment, 80% of the maximum strain in cartilage developed immediately, after which the cartilage continued to deform slowly until the 30 min time point. Cartilage strains and meniscus movement obtained from the FE model matched adequately with the experimentally measured values. Reducing the fibril network stiffness increased the mean strains substantially, while the creep rate was primarily influenced by an increase in the nonfibrillar matrix modulus. Changing the initial permeability and preventing fluid flow through noncontacting surfaces had a negligible effect on cartilage strains. The present results improve understanding of the mechanisms controlling articular cartilage strains and meniscal movements in a knee joint under physiological static loading. Ultimately a validated model could be used as a noninvasive diagnostic tool to locate cartilage areas at risk for degeneration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Biomechanical and neuromuscular adaptations during the landing phase of a stepping-down task in patients with early or established knee osteoarthritis.

    PubMed

    Sanchez-Ramirez, Diana C; Malfait, Bart; Baert, Isabel; van der Leeden, Marike; van Dieën, Jaap; Lems, Willem F; Dekker, Joost; Luyten, Frank P; Verschueren, Sabine

    2016-06-01

    To compare the knee joint kinematics, kinetics and EMG activity patterns during a stepping-down task in patients with knee osteoarthritis (OA) with control subjects. 33 women with knee OA (early OA, n=14; established OA n=19) and 14 female control subjects performed a stepping-down task from a 20cm step. Knee joint kinematics, kinetics and EMG activity were recorded on the stepping-down leg during the loading phase. During the stepping-down task patients with established knee OA showed greater normalized medial hamstrings activity (p=0.034) and greater vastus lateralis-medial hamstrings co-contraction (p=0.012) than controls. Greater vastus medialis-medial hamstrings co-contraction was found in patients with established OA compared to control subjects (p=0.040) and to patients with early OA (p=0.023). Self-reported knee instability was reported in 7% and 32% of the patients with early and established OA, respectively. The greater EMG co-activity found in established OA might suggest a less efficient use of knee muscles or an attempt to compensate for greater knee laxity usually present in patients with established OA. In the early stage of the disease, the biomechanical and neuromuscular control of stepping-down is not altered compared to healthy controls. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Progressive cell-mediated changes in articular cartilage and bone in mice are initiated by a single session of controlled cyclic compressive loading.

    PubMed

    Ko, Frank C; Dragomir, Cecilia L; Plumb, Darren A; Hsia, Allison W; Adebayo, Olufunmilayo O; Goldring, Steven R; Wright, Timothy M; Goldring, Mary B; van der Meulen, Marjolein C H

    2016-11-01

    We previously showed that repetitive cyclic loading of the mouse knee joint causes changes that recapitulate the features of osteoarthritis (OA) in humans. By applying a single loading session, we characterized the temporal progression of the structural and compositional changes in subchondral bone and articular cartilage. We applied loading during a single 5-minute session to the left tibia of adult (26-week-old) C57Bl/6 male mice at a peak load of 9.0N for 1,200 cycles. Knee joints were collected at times 0, 1, and 2 weeks after loading. The changes in articular cartilage and subchondral bone were analyzed by histology, immunohistochemistry (caspase-3 and cathepsin K), and microcomputed tomography. At time 0, no change was evident in chondrocyte viability or cartilage or subchondral bone integrity. However, cartilage pathology demonstrated by localized thinning and proteoglycan loss occurred at 1 and 2 weeks after the single session of loading. Transient cancellous bone loss was evident at 1 week, associated with increased osteoclast number. Bone loss was reversed to control levels at 2 weeks. We observed formation of fibrous and cartilaginous tissues at the joint margins at 1 and 2 weeks. Our findings demonstrate that a single session of noninvasive loading leads to the development of OA-like morphological and cellular alterations in articular cartilage and subchondral bone. The loss in subchondral trabecular bone mass and thickness returns to control levels at 2 weeks, whereas the cartilage thinning and proteoglycan loss persist. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1941-1949, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  12. Energy expended and knee joint load accumulated when walking, running, or standing for the same amount of time.

    PubMed

    Miller, Ross H; Edwards, W Brent; Deluzio, Kevin J

    2015-01-01

    Evidence suggests prolonged bouts of sitting are unhealthy, and some public health messages have recently recommended replacing sitting with more standing. However, the relative benefits of replacing sitting with standing compared to locomotion are not known. Specifically, the biomechanical consequences of standing compared to other sitting-alternatives like walking and running are not well known and are usually not considered in studies on sitting. We compared the total knee joint load accumulated (TKJLA) and the total energy expended (TEE) when performing either walking, running, or standing for a common exercise bout duration (30 min). Walking and running both (unsurprisingly) had much more TEE than standing (+300% and +1100%, respectively). TKJLA was similar between walking and standing and 74% greater in running. The results suggest that standing is a poor replacement for walking and running if one wishes to increases energy expenditure, and may be particularly questionable for use in individuals at-risk for knee osteoarthritis due to its surprisingly high TKJLA (just as high as walking, 56% of the load in running) and the type of loading (continuous compression) it places on cartilage. However, standing has health benefits as an "inactivity interrupter" that extend beyond its direct energy expenditure. We suggest that future studies on standing as an inactivity intervention consider the potential biomechanical consequences of standing more often throughout the day, particularly in the case of prolonged bouts of standing. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Changes in Gait with Anteriorly Added Mass: A Pregnancy Simulation Study

    PubMed Central

    Ogamba, Maureen I.; Loverro, Kari L.; Laudicina, Natalie M.; Gill, Simone V.; Lewis, Cara L.

    2016-01-01

    During pregnancy, the female body experiences structural changes, such as weight gain. As pregnancy advances, most of the additional mass is concentrated anteriorly on the lower trunk. The purpose of this study is to analyze kinematic and kinetic changes when load is added anteriorly to the trunk, simulating a physical change experienced during pregnancy. Twenty healthy females walked on a treadmill while wearing a custom made pseudo-pregnancy sac (1 kg) under three load conditions: sac only, 10 pound condition (4.535 kg added anteriorly), and 20 pound condition (9.07 kg added anteriorly), used to simulate pregnancy, in the second trimester and at full term pregnancy, respectively. The increase in anterior mass resulted in kinematic changes at the knee, hip, pelvis, and trunk in the sagittal and frontal planes. Additionally, ankle, knee, and hip joint moments normalized to baseline mass increased with increased load; however, these moments decreased when normalized to total mass. These kinematic and kinetic changes may suggest that women modify gait biomechanics to reduce the effect of added load. Furthermore, the increase in joint moments increases stress on the musculoskeletal system and may contribute to musculoskeletal pain. PMID:26958743

  14. A mathematical model of forces in the knee under isometric quadriceps contractions.

    PubMed

    Huss, R A; Holstein, H; O'Connor, J J

    2000-02-01

    To predict the knee's response to isometric quadriceps contractions against a fixed tibial restraint.Design. Mathematical modelling of the human knee joint. Isometric quadriceps contraction is commonly used for leg muscle strengthening following ligament injury or reconstruction. It is desirable to know the ligament forces induced but direct measurement is difficult. The model, previously applied to the Lachmann or 'drawer' tests, combines an extensible fibre-array representation of the cruciate ligaments with a compressible 'thin-layer' representation of the cartilage. The model allows the knee configuration and force system to be calculated, given flexion angle, restraint position and loading. Inclusion of cartilage deformation increases relative tibio-femoral translation and decreases the ligament forces generated. For each restraint position, a range of flexion angles is found in which no ligament force is required, as opposed to a single flexion angle in the case of incompressible cartilage layers. Knee geometry and ligament elasticity are found to be the most important factors governing the joint's response to isometric quadriceps contractions, but cartilage deformation is found to be more important than in the Lachmann test. Estimation of knee ligament forces is important when devising exercise regimes following ligament injury or reconstruction. The finding of a 'neutral zone' of zero ligament force may have implications for rehabilitation of the ligament-injured knee.

  15. Electromyographic analyses of muscle pre-activation induced by single joint exercise.

    PubMed

    Júnior, Valdinar A R; Bottaro, Martim; Pereira, Maria C C; Andrade, Marcelino M; P Júnior, Paulo R W; Carmo, Jake C

    2010-01-01

    To investigate whether performing a low-intensity, single-joint exercises for knee extensors was an efficient strategy for increasing the number of motor units recruited in the vastus lateralis muscle during a subsequent multi-joint exercises. Nine healthy male participants (23.33+/-3.46 yrs) underwent bouts of exercise in which knee extension and 45 degrees , and leg press exercises were performed in sequence. In the low-intensity bout (R30), 15 unilateral knee extensions were performed, followed by 15 repetitions of the leg presses at 30% and 60% of one maximum repetition load (1-MR), respectively. In the high-intensity bout (R60), the same sequence was performed, but the applied load was 60% of 1-MR for both exercises. A single set of 15 repetitions of the leg press at 60% of 1-MR was performed as a control exercise (CR). The surface electromyographic signals of the vastus lateralis muscle were recorded by means of a linear electrode array. The root mean square (RMS) values were determined for each repetition of the leg press, and linear regressions were calculated from these results. The slopes of the straight lines obtained were then normalized using the linear coefficients of the regression equations and compared using one-way ANOVAs for repeated measures. The slopes observed in the CR were significantly lower than those in the R30 and R60 (p<0.05). The results indicated that the recruitment of motor units was more effective when a single-joint exercise preceded the multi-joint exercise. Article registered in the Australian New Zealand Clinical Trials Registry (ANZCTR) under the number ACTRN12609000413224.

  16. Concurrent prediction of muscle and tibiofemoral contact forces during treadmill gait.

    PubMed

    Guess, Trent M; Stylianou, Antonis P; Kia, Mohammad

    2014-02-01

    Detailed knowledge of knee kinematics and dynamic loading is essential for improving the design and outcomes of surgical procedures, tissue engineering applications, prosthetics design, and rehabilitation. This study used publicly available data provided by the "Grand Challenge Competition to Predict in-vivo Knee Loads" for the 2013 American Society of Mechanical Engineers Summer Bioengineering Conference (Fregly et al., 2012, "Grand Challenge Competition to Predict in vivo Knee Loads," J. Orthop. Res., 30, pp. 503-513) to develop a full body, musculoskeletal model with subject specific right leg geometries that can concurrently predict muscle forces, ligament forces, and knee and ground contact forces. The model includes representation of foot/floor interactions and predicted tibiofemoral joint loads were compared to measured tibial loads for two different cycles of treadmill gait. The model used anthropometric data (height and weight) to scale the joint center locations and mass properties of a generic model and then used subject bone geometries to more accurately position the hip and ankle. The musculoskeletal model included 44 muscles on the right leg, and subject specific geometries were used to create a 12 degrees-of-freedom anatomical right knee that included both patellofemoral and tibiofemoral articulations. Tibiofemoral motion was constrained by deformable contacts defined between the tibial insert and femoral component geometries and by ligaments. Patellofemoral motion was constrained by contact between the patellar button and femoral component geometries and the patellar tendon. Shoe geometries were added to the feet, and shoe motion was constrained by contact between three shoe segments per foot and the treadmill surface. Six-axis springs constrained motion between the feet and shoe segments. Experimental motion capture data provided input to an inverse kinematics stage, and the final forward dynamics simulations tracked joint angle errors for the left leg and upper body and tracked muscle length errors for the right leg. The one cycle RMS errors between the predicted and measured tibia contact were 178 N and 168 N for the medial and lateral sides for the first gait cycle and 209 N and 228 N for the medial and lateral sides for the faster second gait cycle. One cycle RMS errors between predicted and measured ground reaction forces were 12 N, 13 N, and 65 N in the anterior-posterior, medial-lateral, and vertical directions for the first gait cycle and 43 N, 15 N, and 96 N in the anterior-posterior, medial-lateral, and vertical directions for the second gait cycle.

  17. Immediate effect of valgus bracing on knee joint moments in meniscectomised patients: An exploratory study.

    PubMed

    Thorning, Maria; Thorlund, Jonas B; Roos, Ewa M; Wrigley, Tim V; Hall, Michelle

    2016-12-01

    Patients undergoing medial arthroscopic partial meniscectomy are at increased risk of developing and/or progressing knee osteoarthritis, with increased medial compartment load being a potential contributor. The aim of this study was to evaluate the immediate effect of a valgus unloader knee brace on knee joint moments in patients following medial arthroscopic partial meniscectomy. Within-participant design. Twenty-two patients (age 35-55 years) who had undergone medial arthroscopic partial meniscectomy within the previous 8-15 months completed three-dimensional analysis of gait, forward lunge and one-leg rise during two conditions: with and without a valgus unloader knee brace. Outcome measures included the peak and impulse of the knee adduction moment and the peak knee flexion moment. The peak knee flexion moment increased during brace condition for forward lunge (mean difference [95% CI]) 0.54 [0.27-0.82] (Nm/(BW×HT)%), p<0.001 and one-leg rise (mean difference 0.45 [95% CI 0.08-0.82] (Nm/(BW×HT)%), p=0.022). No other significant differences were found between conditions in any of the included tasks. A significant effect of the knee brace was detected in terms of an increase in peak knee flexion moment during the more demanding tasks such as forward lunge and one-leg rise. This increase implies enhanced stability of the knee provided by the brace, which may induce increased knee function and knee-related confidence during strenuous tasks. Future research is required to explore the structural implications. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  18. The use of synthetic ligaments in the design of an enhanced stability total knee joint replacement.

    PubMed

    Stokes, Michael D; Greene, Brendan C; Pietrykowski, Luke W; Gambon, Taylor M; Bales, Caroline E; DesJardins, John D

    2018-03-01

    Current total knee replacement designs work to address clinically desired knee stability and range of motion through a balance of retained anatomy and added implant geometry. However, simplified implant geometries such as bearing surfaces, posts, and cams are often used to replace complex ligamentous constraints that are sacrificed during most total knee replacement procedures. This article evaluates a novel total knee replacement design that incorporates synthetic ligaments to enhance the stability of the total knee replacement system. It was hypothesized that by incorporating artificial cruciate ligaments into a total knee replacement design at specific locations and lengths, the stability of the total knee replacement could be significantly altered while maintaining active ranges of motion. The ligament attachment mechanisms used in the design were evaluated using a tensile test, and determined to have a safety factor of three with respect to expected ligamentous loading in vivo. Following initial computational modeling of possible ligament orientations, a physical prototype was constructed to verify the function of the design by performing anterior/posterior drawer tests under physiologic load. Synthetic ligament configurations were found to increase total knee replacement stability up to 94% compared to the no-ligament case, while maintaining total knee replacement flexion range of motion between 0° and 120°, indicating that a total knee replacement that incorporates synthetic ligaments with calibrated location and lengths should be able to significantly enhance and control the kinematic performance of a total knee replacement system.

  19. Biomechanical Effects of Stiffness in Parallel With the Knee Joint During Walking.

    PubMed

    Shamaei, Kamran; Cenciarini, Massimo; Adams, Albert A; Gregorczyk, Karen N; Schiffman, Jeffrey M; Dollar, Aaron M

    2015-10-01

    The human knee behaves similarly to a linear torsional spring during the stance phase of walking with a stiffness referred to as the knee quasi-stiffness. The spring-like behavior of the knee joint led us to hypothesize that we might partially replace the knee joint contribution during stance by utilizing an external spring acting in parallel with the knee joint. We investigated the validity of this hypothesis using a pair of experimental robotic knee exoskeletons that provided an external stiffness in parallel with the knee joints in the stance phase. We conducted a series of experiments involving walking with the exoskeletons with four levels of stiffness, including 0%, 33%, 66%, and 100% of the estimated human knee quasi-stiffness, and a pair of joint-less replicas. The results indicated that the ankle and hip joints tend to retain relatively invariant moment and angle patterns under the effects of the exoskeleton mass, articulation, and stiffness. The results also showed that the knee joint responds in a way such that the moment and quasi-stiffness of the knee complex (knee joint and exoskeleton) remains mostly invariant. A careful analysis of the knee moment profile indicated that the knee moment could fully adapt to the assistive moment; whereas, the knee quasi-stiffness fully adapts to values of the assistive stiffness only up to ∼80%. Above this value, we found biarticular consequences emerge at the hip joint.

  20. A handheld computer as part of a portable in vivo knee joint load monitoring system

    PubMed Central

    Szivek, JA; Nandakumar, VS; Geffre, CP; Townsend, CP

    2009-01-01

    In vivo measurement of loads and pressures acting on articular cartilage in the knee joint during various activities and rehabilitative therapies following focal defect repair will provide a means of designing activities that encourage faster and more complete healing of focal defects. It was the goal of this study to develop a totally portable monitoring system that could be used during various activities and allow continuous monitoring of forces acting on the knee. In order to make the monitoring system portable, a handheld computer with custom software, a USB powered miniature wireless receiver and a battery-powered coil were developed to replace a currently used computer, AC powered bench top receiver and power supply. A Dell handheld running Windows Mobile operating system(OS) programmed using Labview was used to collect strain measurements. Measurements collected by the handheld based system connected to the miniature wireless receiver were compared with the measurements collected by a hardwired system and a computer based system during bench top testing and in vivo testing. The newly developed handheld based system had a maximum accuracy of 99% when compared to the computer based system. PMID:19789715

  1. The Influence of Minimalist Footwear on Knee and Ankle Load during Depth Jumping.

    PubMed

    Sinclair, J; Hobbs, S J; Selfe, J

    2015-01-01

    Plyometric training is used by athletes to promote strength and explosive power. However plyometric activities such as depth jumping are associated with a high incidence of injuries. This study examined the influence of minimalist and conventional footwear on the loads experienced by the patellofemoral joint and Achilles tendon. Patellofemoral and Achilles tendon forces were obtained from ten male participants using an eight-camera 3D motion capture system and force platform data as they completed depth jumps in both footwear conditions. Differences between footwear were calculated using paired t-tests. The results show that the minimalist footwear were associated with significantly lower patellofemoral contact force/pressure and also knee abduction moment. It is therefore recommended, based on these observations, that those who are susceptible to knee pain should consider minimalist footwear when performing plyometric training.

  2. Increasing hip and knee flexion during a drop-jump task reduces tibiofemoral shear and compressive forces: implications for ACL injury prevention training.

    PubMed

    Tsai, Liang-Ching; Ko, Yi-An; Hammond, Kyle E; Xerogeanes, John W; Warren, Gordon L; Powers, Christopher M

    2017-12-01

    Although most ACL injury prevention programmes encourage greater hip and knee flexion during landing, it remains unknown how this technique influences tibiofemoral joint forces. We examined whether a landing strategy utilising greater hip and knee flexion decreases tibiofemoral anterior shear and compression. Twelve healthy women (25.9 ± 3.5 years) performed a drop-jump task before and after a training session (10-15 min) that emphasised greater hip and knee flexion. Peak tibiofemoral anterior shear and compressive forces were calculated using an electromyography (EMG)-driven knee model that incorporated joint kinematics, EMG and participant-specific muscle volumes and patella tendon orientation measured using magnetic resonance imaging (MRI). Participants demonstrated a decrease in peak anterior tibial shear forces (11.1 ± 3.3 vs. 9.6 ± 2.7 N · kg -1 ; P = 0.008) and peak tibiofemoral compressive forces (68.4 ± 7.6 vs. 62.0 ± 5.5 N · kg -1 ; P = 0.015) post-training. The decreased peak anterior tibial shear was accompanied by a decrease in the quadriceps anterior shear force, while the decreased peak compressive force was accompanied by decreased ground reaction force and hamstring forces. Our data provide justification for injury prevention programmes that encourage greater hip and knee flexion during landing to reduce tibiofemoral joint loading.

  3. Change in knee contact force with simulated change in body weight.

    PubMed

    Knarr, Brian A; Higginson, Jill S; Zeni, Joseph A

    2016-02-01

    The relationship between obesity, weight gain and progression of knee osteoarthritis is well supported, suggesting that excessive joint loading may be a mechanism responsible for cartilage deterioration. Examining the influence of weight gain on joint compressive forces is difficult, as both muscles and ground reaction forces can have a significant impact on the forces experienced during gait. While previous studies have examined the relationship between body weight and knee forces, these studies have used models that were not validated using experimental data. Therefore, the objective of this study was to evaluate the relationship between changes in body weight and changes in knee joint contact forces for an individual's gait pattern using musculoskeletal modeling that is validated against known internal compressive forces. Optimal weighting constants were determined for three subjects to generate valid predictions of knee contact forces (KCFs) using in vivo data collection with instrumented total knee arthroplasty. A total of five simulations per walking trial were generated for each subject, from 80% to 120% body weight in 10% increments, resulting in 50 total simulations. The change in peak KCF with respect to body weight was found to be constant and subject-specific, predominantly determined by the peak force during the baseline condition at 100% body weight. This relationship may be further altered by any change in kinematics or body mass distribution that may occur as a result of a change in body weight or exercise program.

  4. 21 CFR 888.3480 - Knee joint femorotibial metallic constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metallic constrained... Knee joint femorotibial metallic constrained cemented prosthesis. (a) Identification. A knee joint... knee joint. The device prevents dislocation in more than one anatomic plane and has components that are...

  5. The influence of a change in the meniscus cross-sectional shape on the medio-lateral translation of the knee joint and meniscal extrusion

    PubMed Central

    Daszkiewicz, Karol; Witkowski, Wojciech; Chróścielewski, Jacek; Ferenc, Tomasz; Baczkowski, Boguslaw

    2018-01-01

    Objective The purpose of this study was to evaluate the influence of a change in the meniscus cross sectional shape on its position and on the biomechanics of a knee joint. Methods One main finite element model of a left knee joint was created on the basis of MRI images. The model consisted of bones, articular cartilages, menisci and ligaments. Eight variants of this model with an increased or decreased meniscus height were then prepared. Nonlinear static analyses with a fixed flexion/extension movement for a compressive load of 1000 N were performed. The additional analyses for those models with a constrained medio-lateral relative bone translation allowed for an evaluation of the influence of this translation on a meniscus external shift. Results It was observed that a decrease in the meniscus height caused a decrease in the contact area, together with a decrease in the contact force between the flattened meniscus and the cartilage. For the models with an increased meniscus height, a maximal value of force acting on the meniscus in a medio-lateral direction was obtained. The results have shown that the meniscus external shift was approximately proportional to the meniscus slope angle, but that relationship was modified by a medio-lateral relative bone translation. It was found that the translation of the femur relative to the tibia may be dependent on the geometry of the menisci. Conclusions The results have suggested that a change in the meniscus geometry in the cross sectional plane can considerably affect not only the meniscal external shift, but also the medio-lateral translation of the knee joint as well as the congruency of the knee joint. PMID:29447236

  6. The influence of a change in the meniscus cross-sectional shape on the medio-lateral translation of the knee joint and meniscal extrusion.

    PubMed

    Luczkiewicz, Piotr; Daszkiewicz, Karol; Witkowski, Wojciech; Chróścielewski, Jacek; Ferenc, Tomasz; Baczkowski, Boguslaw

    2018-01-01

    The purpose of this study was to evaluate the influence of a change in the meniscus cross sectional shape on its position and on the biomechanics of a knee joint. One main finite element model of a left knee joint was created on the basis of MRI images. The model consisted of bones, articular cartilages, menisci and ligaments. Eight variants of this model with an increased or decreased meniscus height were then prepared. Nonlinear static analyses with a fixed flexion/extension movement for a compressive load of 1000 N were performed. The additional analyses for those models with a constrained medio-lateral relative bone translation allowed for an evaluation of the influence of this translation on a meniscus external shift. It was observed that a decrease in the meniscus height caused a decrease in the contact area, together with a decrease in the contact force between the flattened meniscus and the cartilage. For the models with an increased meniscus height, a maximal value of force acting on the meniscus in a medio-lateral direction was obtained. The results have shown that the meniscus external shift was approximately proportional to the meniscus slope angle, but that relationship was modified by a medio-lateral relative bone translation. It was found that the translation of the femur relative to the tibia may be dependent on the geometry of the menisci. The results have suggested that a change in the meniscus geometry in the cross sectional plane can considerably affect not only the meniscal external shift, but also the medio-lateral translation of the knee joint as well as the congruency of the knee joint.

  7. Tibiofemoral joint contact area and pressure after single- and double-bundle anterior cruciate ligament reconstruction.

    PubMed

    Morimoto, Yusuke; Ferretti, Mario; Ekdahl, Max; Smolinski, Patrick; Fu, Freddie H

    2009-01-01

    The purpose of this study was to compare the tibiofemoral contact area and pressure after single-bundle (SB) and double-bundle (DB) anterior cruciate ligament (ACL) reconstruction by use of 2 femoral and 2 tibial tunnels in intact cadaveric knees. Tibiofemoral contact area and mean and maximum pressures were measured by pressure-sensitive film (Fujifilm, Valhalla, NY) inserted between the tibia and femur. The knee was subjected to a 1,000-N axial load by use of a uniaxial testing machine at 0 degrees , 15 degrees , 30 degrees , and 45 degrees of flexion. Three conditions were evaluated: (1) intact ACL, (2) SB ACL reconstruction (n = 10 knees), and (3) DB ACL reconstruction (n = 9 knees). When compared with the intact knee, DB ACL reconstruction showed no significant difference in tibiofemoral contact area and mean and maximum pressures. SB ACL reconstruction had a significantly smaller contact area on the lateral and medial tibiofemoral joints at 30 degrees and 15 degrees of flexion. SB ACL reconstruction also had significantly higher mean pressures at 15 degrees of flexion on the medial tibiofemoral joint and at 0 degrees and 15 degrees of flexion on the lateral tibiofemoral joint, as well as significantly higher maximum pressures at 15 degrees of flexion on the lateral tibiofemoral joint. SB ACL reconstruction resulted in a significantly smaller tibiofemoral contact area and higher pressures. DB ACL more closely restores the normal contact area and pressure mainly at low flexion angles. Our findings suggest that the changes in the contact area and pressures after SB ACL reconstruction may be one of the causes of osteoarthritis on long-term follow-up. DB ACL reconstruction may reduce the incidence of osteoarthritis by closely restoring contact area and pressure.

  8. The effects of altering initial ground contact in the running gait of an individual with transtibial amputation.

    PubMed

    Waetjen, Linda; Parker, Matthew; Wilken, Jason M

    2012-09-01

    High rates of osteoarthritis of the knee joint of the intact limb in persons with amputation have raised concern about the long-term consequence of running. The purpose of this intervention was to determine if loading of the knee on the intact limb of a person with transtibial amputation during running could be decreased by changing the intact limb initial ground contact from rear foot to forefoot strike. This study compared kinematic, kinetic and temporal-spatial data collected while a 27-year-old male, who sustained a traumatic unilateral transtibial amputation of the left lower extremity, ran using a forefoot ground contact and again while using a heel first ground contact. Changing initial ground contact from rear foot strike to forefoot strike resulted in decreases in vertical ground reaction forces at impact, peak knee moments in stance, peak knee powers, and improved symmetry in step length. This case suggests forefoot initial contact of the intact limb may minimize loading of the knee on the intact limb in individuals with transtibial amputation.

  9. Plyometric Long Jump Training With Progressive Loading Improves Kinetic and Kinematic Swimming Start Parameters.

    PubMed

    Rebutini, Vanessa Z; Pereira, Gleber; Bohrer, Roberta C D; Ugrinowitsch, Carlos; Rodacki, André L F

    2016-09-01

    Rebutini, VZ, Pereira, G, Bohrer, RCD, Ugrinowitsch, C, and Rodacki, ALF. Plyometric long jump training with progressive loading improves kinetic and kinematic swimming start parameters. J Strength Cond Res 30(9): 2392-2398, 2016-This study was aimed to determine the effects of a plyometric long jump training program on torque around the lower limb joints and kinetic and kinematics parameters during the swimming jump start. Ten swimmers performed 3 identical assessment sessions, measuring hip and knee muscle extensors during maximal voluntary isometric contraction and kinetic and kinematics parameters during the swimming jump start, at 3 instants: INI (2 weeks before the training program, control period), PRE (2 weeks after INI measurements), and POST (24-48 hours after 9 weeks of training). There were no significant changes from INI to PRE measurements. However, the peak torque and rate of torque development increased significantly from PRE to POST measurements for both hip (47 and 108%) and knee (24 and 41%) joints. There were significant improvements to the horizontal force (7%), impulse (9%), and angle of resultant force (19%). In addition, there were significant improvements to the center of mass displacement (5%), horizontal takeoff velocity (16%), horizontal velocity at water entrance (22%), and peak angle velocity for the knee (15%) and hip joints (16%). Therefore, the plyometric long jump training protocol was effective to enhance torque around the lower limb joints and to control the resultant vector direction, to increase the swimming jump start performance. These findings suggest that coaches should use long jump training instead of vertical jump training to improve swimming start performance.

  10. Effects of a powered ankle-foot prosthesis on kinetic loading of the unaffected leg during level-ground walking

    PubMed Central

    2013-01-01

    Background People with a lower-extremity amputation that use conventional passive-elastic ankle-foot prostheses encounter a series of stress-related challenges during walking such as greater forces on their unaffected leg, and may thus be predisposed to secondary musculoskeletal injuries such as chronic joint disorders. Specifically, people with a unilateral transtibial amputation have an increased susceptibility to knee osteoarthritis, especially in their unaffected leg. Previous studies have hypothesized that the development of this disorder is linked to the abnormally high peak knee external adduction moments encountered during walking. An ankle-foot prosthesis that supplies biomimetic power could potentially mitigate the forces and knee adduction moments applied to the unaffected leg of a person with a transtibial amputation, which could, in turn, reduce the risk of knee osteoarthritis. We hypothesized that compared to using a passive-elastic prosthesis, people with a transtibial amputation using a powered ankle-foot prosthesis would have lower peak resultant ground reaction forces, peak external knee adduction moments, and corresponding loading rates applied to their unaffected leg during walking over a wide range of speeds. Methods We analyzed ground reaction forces and knee joint kinetics of the unaffected leg of seven participants with a unilateral transtibial amputation and seven age-, height- and weight-matched non-amputees during level-ground walking at 0.75, 1.00, 1.25, 1.50, and 1.75 m/s. Subjects with an amputation walked while using their own passive-elastic prosthesis and a powered ankle-foot prosthesis capable of providing net positive mechanical work and powered ankle plantar flexion during late stance. Results Use of the powered prosthesis significantly decreased unaffected leg peak resultant forces by 2-11% at 0.75-1.50 m/s, and first peak knee external adduction moments by 21 and 12% at 1.50 and 1.75 m/s, respectively. Loading rates were not significantly different between prosthetic feet. Conclusions Use of a biomimetic powered ankle-foot prosthesis decreased peak resultant force at slow and moderate speeds and knee external adduction moment at moderate and fast speeds on the unaffected leg of people with a transtibial amputation during level-ground walking. Thus, use of an ankle-foot prosthesis that provides net positive mechanical work could reduce the risk of comorbidities such as knee osteoarthritis. PMID:23758860

  11. Intra-articular injections of HYADD4-G in male professional soccer players with traumatic or degenerative knee chondropathy. A pilot, prospective study.

    PubMed

    Tamburrino, Pasquale; Castellacci, Enrico

    2016-12-01

    Knee injuries are very common in some sports and particularly in soccer due to the highly repetitive loading of the mechanical stress involved in this practice. Knee-joint injuries account for 40% of all different kinds of lesions. Traumatic or degenerative patellofemoral or tibialfemoral chondropaties of knee cause disabling symptoms, joint pain and/or dysfunctions. The aim of the study was to evaluate the effects of HYADD4-G, a hydrogel based on a hyaluronic acid derivative, in professional soccer players affected by traumatic or degenerative knee chondropathy. Thirty male professional soccer players participants in the Italian League 2014-2015, affected by traumatic or degenerative knee patellofemoral (N.=12) or tibiofemoral (N.=18) chondropathy assessed through MRI and/or arthroscopy of knee joints and the ICRS staging (International Cartilage Repair Society ≤3a), were enrolled in this pilot prospective study. Patients underwent 2 intra-articular (IA) injections of HYADD4-G (3 mL of 8 mg/mL) at one week interval. Patients were prospectively evaluated at baseline and then at 1, 3 and 6 months after the treatment by the Osteoarthritis Outcome Score (KOOS) Score (main outcome) and by the Visual Analog Scale (VAS) to evaluate pain. A significant improvement in all clinical endpoints from pretreatment to different times of evaluation was found in all patients. ANOVA with repeated measure using the SPSS has showed significantly better results in term of KOOS and VAS scores at 1, 3 and 6 months compared to the pre-injection value (P<0.05). IA HYADD4-G is highly effective to improve resting and walking pain in professional male soccer players with traumatic or degenerative knee chondropathy.

  12. Association of baseline knee sagittal dynamic joint stiffness during gait and 2-year patellofemoral cartilage damage worsening in knee osteoarthritis.

    PubMed

    Chang, A H; Chmiel, J S; Almagor, O; Guermazi, A; Prasad, P V; Moisio, K C; Belisle, L; Zhang, Y; Hayes, K; Sharma, L

    2017-02-01

    Knee sagittal dynamic joint stiffness (DJS) describes the biomechanical interaction between change in external knee flexion moment and flexion angular excursion during gait. In theory, greater DJS may particularly stress the patellofemoral (PF) compartment and thereby contribute to PF osteoarthritis (OA) worsening. We hypothesized that greater baseline knee sagittal DJS is associated with PF cartilage damage worsening 2 years later. Participants all had OA in at least one knee. Knee kinematics and kinetics during gait were recorded using motion capture systems and force plates. Knee sagittal DJS was computed as the slope of the linear regression line for knee flexion moments vs angles during the loading response phase. Knee magnetic resonance imaging (MRI) scans were obtained at baseline and 2 years later. We assessed the association between baseline DJS and baseline-to-2-year PF cartilage damage worsening using logistic regression with generalized estimating equations (GEE). Our sample had 391 knees (204 persons): mean age 64.2 years (SD 10.0); body mass index (BMI) 28.4 kg/m 2 (5.7); 76.5% women. Baseline knee sagittal DJS was associated with baseline-to-2-year cartilage damage worsening in the lateral (OR = 5.35, 95% CI: 2.37-12.05) and any PF (OR = 2.99, 95% CI: 1.27-7.04) compartment. Individual components of baseline DJS (i.e., change in knee moment or angle) were not associated with subsequent PF disease worsening. Capturing the concomitant effect of knee kinetics and kinematics during gait, knee sagittal DJS is a potentially modifiable risk factor for PF disease worsening. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  13. Association of Baseline Knee Sagittal Dynamic Joint Stiffness during Gait and 2-year Patellofemoral Cartilage Damage Worsening in Knee Osteoarthritis

    PubMed Central

    Chang, Alison H.; Chmiel, Joan S.; Almagor, Orit; Guermazi, Ali; Prasad, Pottumarthi V.; Moisio, Kirsten C.; Belisle, Laura; Zhang, Yunhui; Hayes, Karen; Sharma, Leena

    2016-01-01

    Objective Knee sagittal dynamic joint stiffness (DJS) describes the biomechanical interaction between change in external knee flexion moment and flexion angular excursion during gait. In theory, greater DJS may particularly stress the patellofemoral (PF) compartment and thereby contribute to PF osteoarthritis (OA) worsening. We hypothesized that greater baseline knee sagittal DJS is associated with PF cartilage damage worsening 2 years later. Methods Participants all had OA in at least one knee. Knee kinematics and kinetics during gait were recorded using motion capture systems and force plates. Knee sagittal DJS was computed as the slope of the linear regression line for knee flexion moments vs. angles during the loading response phase. Knee MRI scans were obtained at baseline and 2 years later. We assessed the association between baseline DJS and baseline-to-2-year PF cartilage damage worsening using logistic regression with generalized estimating equations. Results Our sample had 391 knees (204 persons): mean age 64.2 years (SD 10.0); BMI 28.4 kg/m2 (5.7); 76.5% women. Baseline knee sagittal DJS was associated with baseline-to-2-year cartilage damage worsening in the lateral (OR=5.35, 95% CI: 2.37–12.05) and any PF (OR=2.99, 95% CI: 1.27–7.04) compartment. Individual components of baseline DJS (i.e., change in knee moment or angle) were not associated with subsequent PF disease worsening. Conclusion Capturing the concomitant effect of knee kinetics and kinematics during gait, knee sagittal DJS is a potentially modifiable risk factor for PF disease worsening. PMID:27729289

  14. Knee Pain and the Use of Various Types of Footwear-A Review.

    PubMed

    Chugthai, Morad; Newman, Jared M; Akil, Samuel; Khlopas, Anton; Sultan, Assem A; Sodhi, Nipun; Bhave, Anil; Harwin, Steven F; Mont, Michael A

    2018-02-08

    Knee pain is a highly prevalent condition in the United States with multiple etiologies, with two of the most common sources being osteoarthritis (OA) and patellofemoral pain (PFP). These conditions can lead to reduced physical function and a poor quality of life. Various modalities have been used to decrease the amount of knee pain that individuals' experience; however, they are not always successful and can be expensive. Several studies have reported on specialized footwear for symptomatic alleviation of conditions that affect the knee, this is because it has been theorized that certain footwear can alter the forces placed by muscles on lower-extremity joints, and can potentially alleviate pain by reducing the load placed on the joint. Therefore, the purpose of this study was to review the current literature on the use of various types of footwear used in patients who suffer from knee pain. Specifically, we evaluated: (1) knee OA and (2) PFP and the effect that different footwear has on patients' symptoms. Multiple different types of footwear and orthosis were utilized to treat patients with chronic knee pain. However, the results from reported outcomes by different studies are conflicting, which warrant further studies. Nevertheless, there are enough positive results to view this as a potential major modality to utilize for the treatment of knee OA. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  15. Do patients with knee osteoarthritis perform sit-to-stand motion efficiently?

    PubMed

    Anan, Masaya; Shinkoda, Koichi; Suzuki, Kentaro; Yagi, Masahide; Ibara, Takuya; Kito, Nobuhiro

    2015-02-01

    The sit-to-stand motion (STS) is a frequently executed activity that is affected by weakness in the quadriceps femoris muscle and knee joint pain in patients with knee osteoarthritis (OA). We investigated whether patients with knee OA can efficiently perform STS through mechanical energy transfer assessments. Participants were 20 women with knee OA and 17 age-matched asymptomatic controls. The center of mass (COM), segment angles, joint moments, and powers during STS were measured. The negative mechanical work in the proximal portion of the shank, negative mean powers in the distal portion of the pelvis and proximal portion of the shank, and the positive mean power in the proximal and distal portions of the thigh were significantly lower in the knee OA group than in the control group. Patients with knee OA primarily performed thoracic forward lean movement, shifting their COM closer to the base of support provided by the feet alone, in an attempt to achieve stability at and after buttocks-off. However, control ability, which generates and absorbs kinetic energy quickly, was not enhanced in these patients, and their motion was unable to increase absorption of the mechanical energy in hip extensors and reduce the load on knee extensors. Furthermore, STS in patients with knee OA had reduced energy absorption in the knee extensors from the shank forward lean movement after buttocks-off, had reduced knee extensor efficiency, and made greater use of physiological energy. These findings suggest that, from the standpoint of mechanical energy transfer, patients with knee OA do not perform STS efficiently. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. The influence of cadence and shoes on patellofemoral joint kinetics in runners with patellofemoral pain.

    PubMed

    Bonacci, Jason; Hall, Michelle; Fox, Aaron; Saunders, Natalie; Shipsides, Tristan; Vicenzino, Bill

    2018-06-01

    To determine the effect of a combination of a minimalist shoe and increased cadence on measures of patellofemoral joint loading during running in individuals with patellofemoral pain. Within-participant repeated measures with four conditions presented in random order: (1) control shoe at preferred cadence; (2) control shoe with +10% cadence; (3) minimalist shoe at preferred cadence; (4) minimalist shoe with +10% cadence. Fifteen recreational runners with patellofemoral pain ran on an instrumented treadmill while three-dimensional motion capture data were acquired. Peak patellofemoral joint stress, joint reaction force, knee extensor moment and knee joint angle during the stance phase of running were calculated. One-way repeated measures ANOVA was used to compare the control condition (1) to the three experimental conditions (2-4). Running in a minimalist shoe at an increased cadence reduced patellofemoral stress and joint reaction force on average by approximately 29% (p<0.001) compared to the control condition. Running in a minimalist shoe at preferred cadence reduced patellofemoral joint stress by 15% and joint reaction force by 17% (p<0.001), compared to the control condition. Running in control shoes at an increased cadence reduced patellofemoral joint stress and joint reaction force by 16% and 19% (p<0.001), respectively, compared to the control condition. In individuals with patellofemoral pain, running in a minimalist shoe at an increased cadence had the greatest reduction in patellofemoral joint loading compared to a control shoe at preferred cadence. This may be an effective intervention to modulate biomechanical factors related to patellofemoral pain. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  17. Anterior cruciate ligament reconstruction and cartilage contact forces--A 3D computational simulation.

    PubMed

    Wang, Lianxin; Lin, Lin; Feng, Yong; Fernandes, Tiago Lazzaretti; Asnis, Peter; Hosseini, Ali; Li, Guoan

    2015-12-01

    Clinical outcome studies showed a high incidence of knee osteoarthritis after anterior cruciate ligament reconstruction. Abnormal joint kinematics and loading conditions were assumed as risking factors. However, little is known on cartilage contact forces after the surgery. A validated computational model was used to simulate anatomic and transtibial single-bundle anterior cruciate ligament reconstructions. Two graft fixation angles (0° and 30°) were simulated for each reconstruction. Biomechanics of the knee was investigated in intact, anterior cruciate ligament deficient and reconstructed conditions when the knee was subjected to 134 N anterior load and 400 N quadriceps load at 0°, 30°, 60° and 90° of flexion. The tibial translation and rotation, graft forces, medial and lateral contact forces were calculated. When the graft was fixed at 0°, the anatomic reconstruction resulted in slightly larger lateral contact force at 0° compared to the intact knee while the transtibial technique led to higher contact force at both 0° and 30° under the muscle load. When graft was fixed at 30°, the anatomic reconstruction overstrained the knee at 0° with larger contact forces, while the transtibial technique resulted in slightly larger contact forces at 30°. This study suggests that neither the anatomic nor the transtibial reconstruction can consistently restore normal knee biomechanics at different flexion angles. The anatomic reconstruction may better restore anteroposterior stability and contact force with the graft fixed at 0°. The transtibial technique may better restore knee anteroposterior stability and articular contact force with the graft fixed at 30° of flexion. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Quantifying the tibiofemoral joint space using x-ray tomosynthesis.

    PubMed

    Kalinosky, Benjamin; Sabol, John M; Piacsek, Kelly; Heckel, Beth; Gilat Schmidt, Taly

    2011-12-01

    Digital x-ray tomosynthesis (DTS) has the potential to provide 3D information about the knee joint in a load-bearing posture, which may improve diagnosis and monitoring of knee osteoarthritis compared with projection radiography, the current standard of care. Manually quantifying and visualizing the joint space width (JSW) from 3D tomosynthesis datasets may be challenging. This work developed a semiautomated algorithm for quantifying the 3D tibiofemoral JSW from reconstructed DTS images. The algorithm was validated through anthropomorphic phantom experiments and applied to three clinical datasets. A user-selected volume of interest within the reconstructed DTS volume was enhanced with 1D multiscale gradient kernels. The edge-enhanced volumes were divided by polarity into tibial and femoral edge maps and combined across kernel scales. A 2D connected components algorithm was performed to determine candidate tibial and femoral edges. A 2D joint space width map (JSW) was constructed to represent the 3D tibiofemoral joint space. To quantify the algorithm accuracy, an adjustable knee phantom was constructed, and eleven posterior-anterior (PA) and lateral DTS scans were acquired with the medial minimum JSW of the phantom set to 0-5 mm in 0.5 mm increments (VolumeRad™, GE Healthcare, Chalfont St. Giles, United Kingdom). The accuracy of the algorithm was quantified by comparing the minimum JSW in a region of interest in the medial compartment of the JSW map to the measured phantom setting for each trial. In addition, the algorithm was applied to DTS scans of a static knee phantom and the JSW map compared to values estimated from a manually segmented computed tomography (CT) dataset. The algorithm was also applied to three clinical DTS datasets of osteoarthritic patients. The algorithm segmented the JSW and generated a JSW map for all phantom and clinical datasets. For the adjustable phantom, the estimated minimum JSW values were plotted against the measured values for all trials. A linear fit estimated a slope of 0.887 (R² = 0.962) and a mean error across all trials of 0.34 mm for the PA phantom data. The estimated minimum JSW values for the lateral adjustable phantom acquisitions were found to have low correlation to the measured values (R² = 0.377), with a mean error of 2.13 mm. The error in the lateral adjustable-phantom datasets appeared to be caused by artifacts due to unrealistic features in the phantom bones. JSW maps generated by DTS and CT varied by a mean of 0.6 mm and 0.8 mm across the knee joint, for PA and lateral scans. The tibial and femoral edges were successfully segmented and JSW maps determined for PA and lateral clinical DTS datasets. A semiautomated method is presented for quantifying the 3D joint space in a 2D JSW map using tomosynthesis images. The proposed algorithm quantified the JSW across the knee joint to sub-millimeter accuracy for PA tomosynthesis acquisitions. Overall, the results suggest that x-ray tomosynthesis may be beneficial for diagnosing and monitoring disease progression or treatment of osteoarthritis by providing quantitative images of JSW in the load-bearing knee.

  19. Mechanism design and optimization of a bionic kangaroo jumping robot

    NASA Astrophysics Data System (ADS)

    Zhang, Y. H.; Zheng, L.; Ge, W. J.; Zou, Z. H.

    2018-03-01

    Hopping robots have broad application prospects in the fields of military reconnaissance, field search or life rescue. However, current hopping robots still face the problems of weak jumping ability and load bearing. Inspired by the jumping of kangaroo, we design a Kangaroo hopping robot “Zbot”, which has two degrees of freedom and three joints. The geared five-bar mechanism is used to decouple the knee and ankle joints of the robot. In order to get a bionic performance, the coupling mechanism parameters are optimized. The simulation and experiments show that the robot has an excellent jumping ability and load capacity.

  20. Determination of representative dimension parameter values of Korean knee joints for knee joint implant design.

    PubMed

    Kwak, Dai Soon; Tao, Quang Bang; Todo, Mitsugu; Jeon, Insu

    2012-05-01

    Knee joint implants developed by western companies have been imported to Korea and used for Korean patients. However, many clinical problems occur in knee joints of Korean patients after total knee joint replacement owing to the geometric mismatch between the western implants and Korean knee joint structures. To solve these problems, a method to determine the representative dimension parameter values of Korean knee joints is introduced to aid in the design of knee joint implants appropriate for Korean patients. Measurements of the dimension parameters of 88 male Korean knee joint subjects were carried out. The distribution of the subjects versus each measured parameter value was investigated. The measured dimension parameter values of each parameter were grouped by suitable intervals called the "size group," and average values of the size groups were calculated. The knee joint subjects were grouped as the "patient group" based on "size group numbers" of each parameter. From the iterative calculations to decrease the errors between the average dimension parameter values of each "patient group" and the dimension parameter values of the subjects, the average dimension parameter values that give less than the error criterion were determined to be the representative dimension parameter values for designing knee joint implants for Korean patients.

  1. Design and Evaluation of a Prosthetic Knee Joint Using the Geared Five-Bar Mechanism.

    PubMed

    Sun, Yuanxi; Ge, Wenjie; Zheng, Jia; Dong, Dianbiao

    2015-11-01

    This paper presents the mechanical design, dynamics analysis and ankle trajectory analysis of a prosthetic knee joint using the geared five-bar mechanism. Compared with traditional four-bar or six-bar mechanisms, the geared five-bar mechanism is better at performing diverse movements and is easy to control. This prosthetic knee joint with the geared five-bar mechanism is capable of fine-tuning its relative instantaneous center of rotation and ankle trajectory. The centrode of this prosthetic knee joint, which is mechanically optimized according to the centrode of human knee joint, is better in the bionic performance than that of a prosthetic knee joint using the four-bar mechanism. Additionally, the stability control of this prosthetic knee joint during the swing and stance phase is achieved by a motor. By adjusting the gear ratio of this prosthetic knee joint, the ankle trajectories of both unilateral and bilateral amputees show less deviations from expected than that of the four-bar knee joint.

  2. [Investigation of body weight ratios on joint structures at different knee flexion angles in patients with unilateral knee arthroplasty].

    PubMed

    Bakırhan, Serkan; Unver, Bayram; Karatosun, Vasfi

    2013-01-01

    The study aims to determine body weight ratios between extremities in patients with unilateral total knee arthroplasty (TKA) at 12 months postoperatively at the static-standing position at 30, 60 and 90 degrees of knee flexion. The study included 52 female patients (mean age 65.6±10.6 years; range 40 to 83 years) who underwent unilateral primary TKA. The force-platform was used to calculate the body-weight ratios of the patients. Body weight ratios on the operated and non-operated limbs of the unilateral TKA patients were examined at standing-static position at 30, 60 and 90 degrees of knee flexion on the force-platform according to their age and body mass index (BMI). The pain levels of the patients were evaluated using the visual analog scale. It was found that unilateral TKA patients placed their body weight on the non-operated limb more at the standing-static position, and 30, 60 and 90 degrees of knee flexion at 12 months postoperatively (p<0.05). It was also found that as the knee flexion degree increased with age, so did TKA patients place their body weight on the nonoperated limb more (p<0.05), and that BMI had no effect on the load distribution difference over the two extremities (p>0.05). During the postoperative period, load asymmetry between the two extremities in patients with unilateral TKA remains the same due to advancing age. This accelerates the osteoarthritis process on the non-operated knee. It is concluded that the age factor should be taken into account while planning physiotherapy and rehabilitation programs for unilateral TKA patients and knee exercise programs aiming to place load over the operated limb should be arranged.

  3. Evaluation of a musculoskeletal model with prosthetic knee through six experimental gait trials.

    PubMed

    Kia, Mohammad; Stylianou, Antonis P; Guess, Trent M

    2014-03-01

    Knowledge of the forces acting on musculoskeletal joint tissues during movement benefits tissue engineering, artificial joint replacement, and our understanding of ligament and cartilage injury. Computational models can be used to predict these internal forces, but musculoskeletal models that simultaneously calculate muscle force and the resulting loading on joint structures are rare. This study used publicly available gait, skeletal geometry, and instrumented prosthetic knee loading data [1] to evaluate muscle driven forward dynamics simulations of walking. Inputs to the simulation were measured kinematics and outputs included muscle, ground reaction, ligament, and joint contact forces. A full body musculoskeletal model with subject specific lower extremity geometries was developed in the multibody framework. A compliant contact was defined between the prosthetic femoral component and tibia insert geometries. Ligament structures were modeled with a nonlinear force-strain relationship. The model included 45 muscles on the right lower leg. During forward dynamics simulations a feedback control scheme calculated muscle forces using the error signal between the current muscle lengths and the lengths recorded during inverse kinematics simulations. Predicted tibio-femoral contact force, ground reaction forces, and muscle forces were compared to experimental measurements for six different gait trials using three different gait types (normal, trunk sway, and medial thrust). The mean average deviation (MAD) and root mean square deviation (RMSD) over one gait cycle are reported. The muscle driven forward dynamics simulations were computationally efficient and consistently reproduced the inverse kinematics motion. The forward simulations also predicted total knee contact forces (166N

  4. Does Success Of Arthroscopic Laser Surgery In The Knee Joint Warrant Its Extension To "Non-Knee" Joints?

    NASA Astrophysics Data System (ADS)

    Smith, Chadwick F.; Johansen, W. Edward; Vangness, C. Thomas; Yamaguchi, Ken; McEleney, Emmett T.; Bales, Peter

    1987-03-01

    One of the authors has performed 162 arthroscopic laser surgeries in the knee joint without any major complication. Other investigators have recently proposed diagnostic arthroscopy and arthroscopic surgery for "non-knee" joints. The authors have proposed that arthroscopic laser surgery he extended to "non-knee" joints. The authors have performed arthroscopic laser surgery on "non-knee" joints of twelve cadavers. One of the authors have performed one successful arthroscopic surgery on a shoulder joint with only a minor, transient complication of subcutaneous emphysema. Is laser arthroscopic surgery safe and effective in "non-knee" joints? The evolving answer appears to be a qualified "Yes," which needs to be verified by a multicenter trial.

  5. Gender differences in tibio-femoral kinematics and quadriceps muscle force during weight-bearing knee flexion in vitro.

    PubMed

    Wünschel, Markus; Wülker, Nikolaus; Müller, Otto

    2013-11-01

    Females have a higher risk in terms of anterior cruciate ligament injuries during sports than males. Reasons for this fact may be different anatomy and muscle recruitment patterns leading to less protection for the cruciate- and collateral-ligaments. This in vitro study aims to evaluate gender differences in knee joint kinematics and muscle force during weight-bearing knee flexions. Thirty-four human knee specimens (17 females/17 males) were mounted on a dynamic knee simulator. Weight-bearing single-leg knee flexions were performed with different amounts of simulated body weight (BW). Gender-specific kinematics was measured with an ultrasonic motion capture system and different loading conditions were examined. Knee joint kinematics did not show significant differences regarding anteroposterior and medial-lateral movement as well as tibial varus-valgus and internal-external rotation. This applied to all simulated amounts of BW. Simulating 100 N BW in contrast to AF50 led to a significant higher quadriceps overall force in female knees from 45° to 85° of flexion in contrast to BW 50 N. In these female specimens, the quadriceps overall force was about 20 % higher than in male knees being constant in higher flexion angles. It is indicated by our results that in a squatting movement females compared with males produce higher muscle forces, suggesting an increased demand for muscular stabilization, whereas tibio-femoral kinematics was similar for both genders.

  6. Kaatsu training to enhance physical function of older adults with knee osteoarthritis: Design of a randomized controlled trial.

    PubMed

    Buford, Thomas W; Fillingim, Roger B; Manini, Todd M; Sibille, Kimberly T; Vincent, Kevin R; Wu, Samuel S

    2015-07-01

    As the U.S. population ages, efficacious interventions are needed to manage pain and maintain physical function among older adults with osteoarthritis (OA). Skeletal muscle weakness is a primary contributory factor to pain and functional decline among persons with OA, thus interventions are needed that improve muscle strength. High-load resistance exercise is the best-known method of improving muscle strength; however high-compressive loads commonly induce significant joint pain among persons with OA. Thus interventions with low-compressive loads are needed which improve muscle strength while limiting joint stress. This study is investigating the potential of an innovative training paradigm, known as Kaatsu, for this purpose. Kaatsu involves performing low-load exercise while externally-applied compression partially restricts blood flow to the active skeletal muscle. The objective of this randomized, single-masked pilot trial is to evaluate the efficacy and feasibility of chronic Kaatsu training for improving skeletal muscle strength and physical function among older adults. Participants aged ≥ 60 years with physical limitations and symptomatic knee OA will be randomly assigned to engage in a 3-month intervention of either (1) center-based, moderate-load resistance training, or (2) Kaatsu training matched for overall workload. Study dependent outcomes include the change in 1) knee extensor strength, 2) objective measures of physical function, and 3) subjective measures of physical function and pain. This study will provide novel information regarding the therapeutic potential of Kaatsu training while also informing about the long-term clinical viability of the paradigm by evaluating participant safety, discomfort, and willingness to continually engage in the intervention. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Joint power and kinematics coordination in load carriage running: Implications for performance and injury.

    PubMed

    Liew, Bernard X W; Morris, Susan; Netto, Kevin

    2016-06-01

    Investigating the impact of incremental load magnitude on running joint power and kinematics is important for understanding the energy cost burden and potential injury-causative mechanisms associated with load carriage. It was hypothesized that incremental load magnitude would result in phase-specific, joint power and kinematic changes within the stance phase of running, and that these relationships would vary at different running velocities. Thirty-one participants performed running while carrying three load magnitudes (0%, 10%, 20% body weight), at three velocities (3, 4, 5m/s). Lower limb trajectories and ground reaction forces were captured, and global optimization was used to derive the variables. The relationships between load magnitude and joint power and angle vectors, at each running velocity, were analyzed using Statistical Parametric Mapping Canonical Correlation Analysis. Incremental load magnitude was positively correlated to joint power in the second half of stance. Increasing load magnitude was also positively correlated with alterations in three dimensional ankle angles during mid-stance (4.0 and 5.0m/s), knee angles at mid-stance (at 5.0m/s), and hip angles during toe-off (at all velocities). Post hoc analyses indicated that at faster running velocities (4.0 and 5.0m/s), increasing load magnitude appeared to alter power contribution in a distal-to-proximal (ankle→hip) joint sequence from mid-stance to toe-off. In addition, kinematic changes due to increasing load influenced both sagittal and non-sagittal plane lower limb joint angles. This study provides a list of plausible factors that may influence running energy cost and injury risk during load carriage running. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Diagnostic Value of Knee Arthrometry in the Prediction of Anterior Cruciate Ligament Strain During Landing

    PubMed Central

    Kiapour, Ata M.; Wordeman, Samuel C.; Paterno, Mark V.; Quatman, Carmen E.; Levine, Jason W.; Goel, Vijay K.; Demetropoulos, Constantine K.; Hewett, Timothy E.

    2014-01-01

    Background Previous studies have indicated that higher knee joint laxity may be indicative of an increased risk of anterior cruciate ligament (ACL) injuries. Despite the frequent clinical use of knee arthrometry in the evaluation of knee laxity, little data exist to correlate instrumented laxity measures and ACL strain during dynamic high-risk activities. Purpose/Hypotheses The purpose of this study was to evaluate the relationships between ACL strain and anterior knee laxity measurements using arthrometry during both a drawer test and simulated bipedal landing (as an identified high-risk injurious task). We hypothesized that a high correlation exists between dynamic ACL strain and passive arthrometry displacement. The secondary hypothesis was that anterior knee laxity quantified by knee arthrometry is a valid predictor of injury risk such that specimens with greater anterior knee laxity would demonstrate increased levels of peak ACL strain during landing. Study Design Controlled laboratory study. Methods Twenty cadaveric lower limbs (mean age, 46 ± 6 years; 10 female and 10 male) were tested using a CompuKT knee arthrometer to measure knee joint laxity. Each specimen was tested under 4 continuous cycles of anterior-posterior shear force (±134 N) applied to the tibial tubercle. To quantify ACL strain, a differential variable reluctance transducer (DVRT) was arthroscopically placed on the ACL (anteromedial bundle), and specimens were retested. Subsequently, bipedal landing from 30 cm was simulated in a subset of 14 specimens (mean age, 45 ± 6 years; 6 female and 8 male) using a novel custom-designed drop stand. Changes in joint laxity and ACL strain under applied anterior shear force were statistically analyzed using paired sample t tests and analysis of variance. Multiple linear regression analyses were conducted to determine the relationship between anterior shear force, anterior tibial translation, and ACL strain. Results During simulated drawer tests, 134 N of applied anterior shear load produced a mean peak anterior tibial translation of 3.1 ± 1.1 mm and a mean peak ACL strain of 4.9% ± 4.3%. Anterior shear load was a significant determinant of anterior tibial translation (P <.0005) and peak ACL strain (P = .04). A significant correlation (r = 0.52, P <.0005) was observed between anterior tibial translation and ACL strain. Cadaveric simulations of landing produced a mean axial impact load of 4070 ± 732 N. Simulated landing significantly increased the mean peak anterior tibial translation to 10.4 ± 3.5 mm and the mean peak ACL strain to 6.8% ± 2.8% (P <.0005) compared with the prelanding condition. Significant correlations were observed between peak ACL strain during simulated landing and anterior tibial translation quantified by knee arthrometry. Conclusion Our first hypothesis is supported by a significant correlation between arthrometry displacement collected during laxity tests and concurrent ACL strain calculated from DVRT measurements. Experimental findings also support our second hypothesis that instrumented measures of anterior knee laxity predict peak ACL strain during landing, while specimens with greater knee laxity demonstrated higher levels of peak ACL strain during landing. Clinical Relevance The current findings highlight the importance of instrumented anterior knee laxity assessments as a potential indicator of the risk of ACL injuries in addition to its clinical utility in the evaluation of ACL integrity. PMID:24275863

  9. Generalised joint hypermobility and knee joint hypermobility: prevalence, knee joint symptoms and health-related quality of life in a Danish adult population.

    PubMed

    Junge, Tina; Henriksen, Peter; Hansen, Sebrina; Østengaard, Lasse; Golightly, Yvonne M; Juul-Kristensen, Birgit

    2017-10-27

    Several biomechanical factors, such as knee joint hypermobility (KJH), are suggested to play a role in the etiology of knee joint symptoms and knee osteoarthritis. Nevertheless, the prevalence or consequences of KJH solely or included in the classification of generalized joint hypermobility (GJHk) is unknown for a general population. Therefore, the objectives were to report the prevalence of self-reported GJHk and KJH, as well as the association of these conditions to knee joint symptoms, severity and duration of symptoms, and health-related quality of life (HRQoL) in a Danish adult population. This study is a cross-sectional population-based survey of 2056 Danish adults. Respondents received online questionnaires of GJHk and KJH, knee joint symptoms, the severity and duration of these, as well as HRQoL. Total response rate was 49% (n = 1006). The prevalence of self-reported GJHk and KJH was 13% and 23%, mostly representing women. More than half of the respondents with GJHk and KJH had knee joint symptoms. The odds for reporting knee joint symptoms, severity of knee joint symptoms and duration of knee joint symptoms were twice as high for respondents with GJHk and KJH. Respondents with GJHk and KJH reported lower HRQoL. GJHk and KJH were frequently reported in the Danish adult population, mostly in women. Respondents with GJHk and KJH were two times more likely to report knee joint-related symptoms such as pain, reduced performance of usual activity and lower HRQoL. The impact of these conditions on HRQoL is comparable with knee osteoarthritis. © 2017 Asia Pacific League of Associations for Rheumatology and John Wiley & Sons Australia, Ltd.

  10. A Mechatronic Loading Device to Stimulate Bone Growth via a Human Knee.

    PubMed

    Prabhala, Sai Krishna; Chien, Stanley; Yokota, Hiroki; Anwar, Sohel

    2016-09-29

    This paper presents the design of an innovative device that applies dynamic mechanical load to human knee joints. Dynamic loading is employed by applying cyclic and periodic force on a target area. The repeated force loading was considered to be an effective modality for repair and rehabilitation of long bones that are subject to ailments like fractures, osteoporosis, osteoarthritis, etc. The proposed device design builds on the knowledge gained in previous animal and mechanical studies. It employs a modified slider-crank linkage mechanism actuated by a brushless Direct Current (DC) motor and provides uniform and cyclic force. The functionality of the device was simulated in a software environment and the structural integrity was analyzed using a finite element method for the prototype construction. The device is controlled by a microcontroller that is programmed to provide the desired loading force at a predetermined frequency and for a specific duration. The device was successfully tested in various experiments for its usability and full functionality. The results reveal that the device works according to the requirements of force magnitude and operational frequency. This device is considered ready to be used for a clinical study to examine whether controlled knee-loading could be an effective regimen for treating the stated bone-related ailments.

  11. A Mechatronic Loading Device to Stimulate Bone Growth via a Human Knee

    PubMed Central

    Prabhala, Sai Krishna; Chien, Stanley; Yokota, Hiroki; Anwar, Sohel

    2016-01-01

    This paper presents the design of an innovative device that applies dynamic mechanical load to human knee joints. Dynamic loading is employed by applying cyclic and periodic force on a target area. The repeated force loading was considered to be an effective modality for repair and rehabilitation of long bones that are subject to ailments like fractures, osteoporosis, osteoarthritis, etc. The proposed device design builds on the knowledge gained in previous animal and mechanical studies. It employs a modified slider-crank linkage mechanism actuated by a brushless Direct Current (DC) motor and provides uniform and cyclic force. The functionality of the device was simulated in a software environment and the structural integrity was analyzed using a finite element method for the prototype construction. The device is controlled by a microcontroller that is programmed to provide the desired loading force at a predetermined frequency and for a specific duration. The device was successfully tested in various experiments for its usability and full functionality. The results reveal that the device works according to the requirements of force magnitude and operational frequency. This device is considered ready to be used for a clinical study to examine whether controlled knee-loading could be an effective regimen for treating the stated bone-related ailments. PMID:27690057

  12. Forefoot strikers exhibit lower running-induced knee loading than rearfoot strikers.

    PubMed

    Kulmala, Juha-Pekka; Avela, Janne; Pasanen, Kati; Parkkari, Jari

    2013-12-01

    Knee pain and Achilles tendinopathies are the most common complaints among runners. The differences in the running mechanics may play an important role in the pathogenesis of lower limb overuse injuries. However, the effect of a runner's foot strike pattern on the ankle and especially on the knee loading is poorly understood. The purpose of this study was to examine whether runners using a forefoot strike pattern exhibit a different lower limb loading profile than runners who use rearfoot strike pattern. Nineteen female athletes with a natural forefoot strike (FFS) pattern and pair-matched women with rearfoot strike (RFS) pattern (n = 19) underwent 3-D running analysis at 4 m·s⁻¹. Joint angles and moments, patellofemoral contact force and stresses, and Achilles tendon forces were analyzed and compared between groups. FFS demonstrated lower patellofemoral contact force and stress compared with heel strikers (4.3 ± 1.2 vs 5.1 ± 1.1 body weight, P = 0.029, and 11.1 ± 2.9 vs 13.0 ± 2.8 MPa, P = 0.04). In addition, knee frontal plane moment was lower in the FFS compared with heel strikers (1.49 ± 0.51 vs 1.97 ± 0.66 N·m·kg⁻¹, P =0.015). At the ankle level, FFS showed higher plantarflexor moment (3.12 ± 0.40 vs 2.54 ± 0.37 N·m·kg⁻¹; P = 0.001) and Achilles tendon force (6.3 ± 0.8 vs 5.1 ± 1.3 body weight; P = 0.002) compared with RFS. To our knowledge, this is the first study that shows differences in patellofemoral loading and knee frontal plane moment between FFS and RFS. FFS exhibit both lower patellofemoral stress and knee frontal plane moment than RFS, which may reduce the risk of running-related knee injuries. On the other hand, parallel increase in ankle plantarflexor and Achilles tendon loading may increase risk for ankle and foot injuries.

  13. Physiotherapy management of knee osteoarthritis.

    PubMed

    Page, Carolyn J; Hinman, Rana S; Bennell, Kim L

    2011-05-01

    Knee osteoarthritis (OA) is a prevalent chronic joint disease causing pain and disability. Physiotherapy, which encompasses a number of modalities, is a non-invasive treatment option in the management of OA. This review summarizes the evidence for commonly used physiotherapy interventions. There is strong evidence to show short-term beneficial effects of exercise on pain and function, although the type of exercise does not seem to influence treatment outcome. Delivery modes, including individual, group or home exercise are all effective, although therapist contact may improve benefits. Attention to improving adherence to exercise is needed to maximize outcomes in the longer-term. Knee taping applied with the aim of realigning the patella and unloading soft tissues can reduce pain. There is also evidence to support the use of knee braces in people with knee OA. Biomechanical studies show that lateral wedge shoe insoles reduce knee load but clinical trials do not support symptomatic benefits. Recent studies suggest individual shoe characteristics also affect knee load and there is current interest in the effect of modified shoe designs. Manual therapy, while not to be used as a stand-alone treatment, may be beneficial. In summary, although the research is not equivocal, there is sufficient evidence to indicate that physiotherapy interventions can reduce pain and improve function in those with knee OA. © 2011 The Authors. International Journal of Rheumatic Diseases © 2011 Asia Pacific League of Associations for Rheumatology and Blackwell Publishing Asia Pty Ltd.

  14. An instrumented spatial linkage for measuring knee joint kinematics.

    PubMed

    Rosvold, Joshua M; Atarod, Mohammad; Frank, Cyril B; Shrive, Nigel G

    2016-01-01

    In this study, the design and development of a highly accurate instrumented spatial linkage (ISL) for kinematic analysis of the ovine stifle joint is described. The ovine knee is a promising biomechanical model of the human knee joint. The ISL consists of six digital rotational encoders providing six degrees of freedom (6-DOF) to its motion. The ISL makes use of the complete and parametrically continuous (CPC) kinematic modeling method to describe the kinematic relationship between encoder readings and the relative positions and orientation of its two ends. The CPC method is useful when calibrating the ISL, because a small change in parameters corresponds to a small change in calculated positions and orientations and thus a smaller optimization error, compared to other kinematic models. The ISL is attached rigidly to the femur and the tibia for motion capture, and the CPC kinematic model is then employed to transform the angle sensor readings to relative motion of the two ends of the linkage, and thereby, the stifle joint motion. The positional accuracy for ISL after calibration and optimization was 0.3±0.2mm (mean +/- standard deviation). The ISL was also evaluated dynamically to ensure that accurate results were maintained, and achieved an accuracy of 0.1mm. Compared to the traditional motion capture methods, this system provides increased accuracy, reduced processing time, and ease of use. Future work will be on the application of the ISL to the ovine gait and determination of in vivo joint motions and tissue loads. Accurate measurement of knee joint kinematics is essential in understanding injury mechanisms and development of potential preventive or treatment strategies. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Which patellofemoral joint imaging features are associated with patellofemoral pain? Systematic review and meta-analysis.

    PubMed

    Drew, B T; Redmond, A C; Smith, T O; Penny, F; Conaghan, P G

    2016-02-01

    To review the association between patellofemoral joint (PFJ) imaging features and patellofemoral pain (PFP). A systematic review of the literature from AMED, CiNAHL, Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, PEDro, EMBASE and SPORTDiscus was undertaken from their inception to September 2014. Studies were eligible if they used magnetic resonance imaging (MRI), computed tomography (CT), ultrasound (US) or X-ray (XR) to compare PFJ features between a PFP group and an asymptomatic control group in people <45 years of age. A pooled meta-analysis was conducted and data was interpreted using a best evidence synthesis. Forty studies (all moderate to high quality) describing 1043 people with PFP and 839 controls were included. Two features were deemed to have a large standardised mean difference (SMD) based on meta-analysis: an increased MRI bisect offset at 0° knee flexion under load (0.99; 95% CI: 0.49, 1.49) and an increased CT congruence angle at 15° knee flexion, both under load (1.40 95% CI: 0.04, 2.76) and without load (1.24; 95% CI: 0.37, 2.12). A medium SMD was identified for MRI patella tilt and patellofemoral contact area. Limited evidence was found to support the association of other imaging features with PFP. A sensitivity analysis showed an increase in the SMD for patella bisect offset at 0° knee flexion (1.91; 95% CI: 1.31, 2.52) and patella tilt at 0° knee flexion (0.99; 95% CI: 0.47, 1.52) under full weight bearing. Certain PFJ imaging features were associated with PFP. Future interventional strategies may be targeted at these features. CRD 42014009503. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  16. Sensitivity of biomechanical outcomes to independent variations of hindfoot and forefoot stiffness in foot prostheses.

    PubMed

    Adamczyk, Peter Gabriel; Roland, Michelle; Hahn, Michael E

    2017-08-01

    Many studies have reported the effects of different foot prostheses on gait, but most results cannot be generalized because the prostheses' properties are seldom reported. We varied hindfoot and forefoot stiffness in an experimental foot prosthesis, in increments of 15N/mm, and tested the parametric effects of these variations on treadmill walking in unilateral transtibial amputees, at speeds from 0.7 to 1.5m/s. We computed outcomes such as prosthesis energy return, center of mass (COM) mechanics, ground reaction forces, and joint mechanics, and computed their sensitivity to component stiffness. A stiffer hindfoot led to reduced prosthesis energy return, increased ground reaction force (GRF) loading rate, and greater stance-phase knee flexion and knee extensor moment. A stiffer forefoot resulted in reduced prosthetic-side ankle push-off and COM push-off work, and increased knee extension and knee flexor moment in late stance. The sensitivity parameters obtained from these tests may be useful in clinical prescription and further research into compensatory mechanisms of joint function. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Muscle-Specific Effective Mechanical Advantage and Joint Impulse in Weightlifting.

    PubMed

    Kipp, Kristof; Harris, Chad

    2017-07-01

    Kipp, K, and Harris, C. Muscle-specific effective mechanical advantage and joint impulse in weightlifting. J Strength Cond Res 31(7): 1905-1910, 2017-Lifting greater loads during weightlifting exercises may theoretically be achieved through increasing the magnitudes of net joint impulses or manipulating the joints' effective mechanical advantage (EMA). The purpose of this study was to investigate muscle-specific EMA and joint impulse as well as impulse-momentum characteristics of the lifter-barbell system across a range of external loads during the execution of the clean. Collegiate-level weightlifters performed submaximal cleans at 65, 75, and 85% of their 1-repetition maximum (1-RM), whereas data from a motion analysis system and a force plate were used to calculate lifter-barbell system impulse and velocity, as well as net extensor impulse generated at the hip, knee, and ankle joints and the EMA of the gluteus maximus, hamstrings, quadriceps, and triceps surae muscles. The results indicated that the lifter-barbell system impulse did not change as load increased, whereas the velocity of the lifter-barbell system decreased with greater load. In addition, the net extensor impulse at all joints increased as load increased. The EMA of all muscles did not, however, change as load increased. The load-dependent effects on the impulse-velocity characteristics of the lifter-barbell system may reflect musculoskeletal force-velocity behaviors, and may further indicate that the weightlifting performance is limited by the magnitude of ground reaction force impulse. In turn, the load-dependent effects observed at the joint level indicated that lifting greater loads were due to greater net extensor impulses generated at the joints of the lower extremity and not greater EMAs of the respective extensor muscles. In combination, these results suggest that lifting greater external loads during the clean is due to the ability to generate large extensor joint impulses, rather than manipulate EMA.

  18. Relationship between knee joint contact forces and external knee joint moments in patients with medial knee osteoarthritis: effects of gait modifications.

    PubMed

    Richards, R E; Andersen, M S; Harlaar, J; van den Noort, J C

    2018-04-30

    To evaluate 1) the relationship between the knee contact force (KCF) and knee adduction and flexion moments (KAM and KFM) during normal gait in people with medial knee osteoarthritis (KOA), 2) the effects on the KCF of walking with a modified gait pattern and 3) the relationship between changes in the KCF and changes in the knee moments. We modeled the gait biomechanics of thirty-five patients with medial KOA using the AnyBody Modeling System during normal gait and two modified gait patterns. We calculated the internal KCF and evaluated the external joint moments (KAM and KFM) against it using linear regression analyses. First peak medial KCF was associated with first peak KAM (R 2  = 0.60) and with KAM and KFM (R 2  = 0.73). Walking with both modified gait patterns reduced KAM (P = 0.002) and the medial to total KCF ratio (P < 0.001) at the first peak. Changes in KAM during modified gait were moderately associated with changes in the medial KCF at the first peak (R 2  = 0.54 and 0.53). At the first peak, KAM is a reasonable substitute for the medial contact force, but not at the second peak. First peak KFM is also a significant contributor to the medial KCF. At the first peak, walking with a modified gait reduced the ratio of the medial to total KCF but not the medial KCF itself. To determine the effects of gait modifications on cartilage loading and disease progression, longitudinal studies and individualized modeling, accounting for motion control, would be required. Copyright © 2018 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  19. Numerical damage models using a structural approach: application in bones and ligaments

    NASA Astrophysics Data System (ADS)

    Arnoux, P. J.; Bonnoit, J.; Chabrand, P.; Jean, M.; Pithioux, M.

    2002-01-01

    The purpose of the present study was to apply knowledge of structural properties to perform numerical simulations with models of bones and knee ligaments exposed to dynamic tensile loading leading to tissue damage. Compact bones and knee ligaments exhibit the same geometrical pattern in their different levels of structural hierarchy from the tropocollagen molecule to the fibre. Nevertheless, their mechanical behaviours differ considerably at the fibril level. These differences are due to the contribution of the joints in the microfibril-fibril-fibre assembly and to the mechanical properties of the structural components. Two finite element models of the fibrous bone and ligament structure were used to describe damage in terms of elastoplastic laws or joint decohesion processes.

  20. Preoperative Pain Neuroscience Education Combined With Knee Joint Mobilization for Knee Osteoarthritis: A Randomized Controlled Trial.

    PubMed

    Lluch, Enrique; Dueñas, Lirios; Falla, Deborah; Baert, Isabel; Meeus, Mira; Sánchez-Frutos, José; Nijs, Jo

    2018-01-01

    This study aimed to first compare the effects of a preoperative treatment combining pain neuroscience education (PNE) with knee joint mobilization versus biomedical education with knee joint mobilization on central sensitization (CS) in patients with knee osteoarthritis, both before and after surgery. Second, we wanted to compare the effects of both interventions on knee pain, disability, and psychosocial variables. Forty-four patients with knee osteoarthritis were allocated to receive 4 sessions of either PNE combined with knee joint mobilization or biomedical education with knee joint mobilization before surgery. All participants completed self-administered questionnaires and quantitative sensory testing was performed at baseline, after treatment and at a 1 month follow-up (all before surgery), and at 3 months after surgery. Significant and clinically relevant differences before and after surgery were found after treatments for both knee pain and disability, and some measures of CS (ie, widespread hyperalgesia, CS inventory), with no significant between-group differences. Other indicators of CS (ie, conditioned pain modulation, temporal summation) did not change over time following either treatment, and in some occasions the observed changes were not in the expected direction. Patients receiving PNE with knee joint mobilization achieved greater improvements in psychosocial variables (pain catastrophizing, kinesiophobia) both before and after surgery. Preoperative PNE combined with knee joint mobilization did not produce any additional benefits over time for knee pain and disability, and CS measures compared with biomedical education with knee joint mobilization. Superior effects in the PNE with knee joint mobilization group were only observed for psychosocial variables related to pain catastrophizing and kinesiophobia.

  1. Sex differences in coupled knee motions during the transition from non-weight bearing to weight bearing.

    PubMed

    Shultz, Sandra J; Beynnon, Bruce D; Schmitz, Randy J

    2009-06-01

    Knee ligament injuries frequently happen when the joint transitions from non-weight bearing (NWB) to weight bearing (WB). To gain insight into the mechanism that produces these injuries, physically active females (N = 41) and males (N = 39) underwent measurement of coupled tibiofemoral joint displacements [anterior tibial translation (ATT) and varus-valgus and internal-external rotations] and neuromuscular responses as the knee transitioned from NWB to WB in response to a 40% body weight load applied under the control of gravity. The transition from NWB to WB produced no difference in ATT between males and females; however, significant sex-based differences were noted for both transverse and frontal plane knee motions. With the knee NWB, females were in a greater absolute valgus compared to males (6.6 vs. 5.0 degrees), and moved through greater varus motion than males during the transition from NW to WB (2.3 vs. 1.4 degrees), resulting in similar valgus alignment for both sexes at peak WB (4.3 vs. 3.6 degrees). In the transverse plane, the knees of females were positioned in more external rotation compared to males when NWB (1.4 vs. -0.3 degrees), then females externally rotated their knees while males internally rotated their knees during the transition from NWB to WB. This resulted in a 3.4 degrees difference in transverse plane knee position at peak WB (2.3 vs. -1.1 degrees). Our findings suggest that the coupled knee motions produced during the transition from NWB to WB are sex dependent, and may provide insight into the knee motion patterns that place females at increased risk of knee ligament injury. Copyright 2008 Orthopaedic Research Society

  2. Medial-to-lateral Ratio of Tibiofemoral Subchondral Bone Area is Adapted to Alignment and Mechanical Load

    PubMed Central

    Eckstein, Felix; Hudelmaier, Martin; Cahue, September; Marshall, Meredith; Sharma, Leena

    2010-01-01

    Malalignment is known to impact the medial-to-lateral load distribution in the tibiofemoral joint. In this longitudinal study, we test the hypothesis that subchondral bone surface areas functionally adapt to the load distribution in malaligned knees. Alignment (hip-knee-ankle angle) was measured from full limb films in 174 participants with knee osteoarthritis. Coronal MR images were acquired at baseline and 26.6±5.4 months later. The subchondral bone surface area of the weight-bearing tibiofemoral cartilages was segmented, with readers blinded to the order of acquisition. The size of the subchondral bone surface areas was computed after triangulation using proprietary software. The hip-knee-ankle angle showed a significant correlation with the tibial (r2=0.25, p<0.0001) and femoral (r2=0.07, p<0.001) ratio of medial-to-lateral subchondral bone surface area. In the tibia, the ratio was significantly different between varus (1.28:1), neutral (1.18:1) and valgus (1.13:1) knees (ANOVA; p<0.00001). Similar observations were made in the weight-bearing femur (0.94:1 in neutral, 0.97.1 in varus, 0.91:1 in valgus knees; ANOVA p=0.018). The annualized longitudinal increase in subchondral bone surface area was significant (p<0.05) in the medial tibia (+0.13%), medial femur (+0.26%) and lateral tibia (+0.19%). In the medial femur, the change between baseline and follow-up was significantly different (ANOVA; p=0.020) between neutral, varus and valgus knees, the increase in surface area being significantly greater (p=0.019) in varus than in neutral knees. Tibiofemoral subchondral bone surface areas are shown to be functionally adapted to the medial-to-lateral load distribution. The longitudinal findings indicate that this adaptational process may continue to take place at advanced age. PMID:19148562

  3. Effect of Exercise-Induced Enhancement of the Leg-Extensor Muscle-Tendon Unit Capacities on Ambulatory Mechanics and Knee Osteoarthritis Markers in the Elderly

    PubMed Central

    Karamanidis, Kiros; Oberländer, Kai Daniel; Niehoff, Anja; Epro, Gaspar; Brüggemann, Gert-Peter

    2014-01-01

    Objective Leg-extensor muscle weakness could be a key component in knee joint degeneration in the elderly because it may result in altered muscular control during locomotion influencing the mechanical environment within the joint. This work aimed to examine whether an exercise-induced enhancement of the triceps surae (TS) and quadriceps femoris (QF) muscle-tendon unit (MTU) capacities would affect mechanical and biological markers for knee osteoarthritis in the elderly. Methods Twelve older women completed a 14-week TS and QF MTU exercise intervention, which had already been established as increasing muscle strength and tendon stiffness. Locomotion mechanics and serum cartilage oligomeric matrix protein (COMP) levels were examined during incline walking. MTU mechanical properties were assessed using simultaneously ultrasonography and dynamometry. Results Post exercise intervention, the elderly had higher TS and QF contractile strength and tendon-aponeurosis stiffness. Regarding the incline gait task, the subjects demonstrated a lower external knee adduction moment and lower knee adduction angular impulse during the stance phase post-intervention. Furthermore, post-intervention compared to pre-intervention, the elderly showed lower external hip adduction moment, but revealed higher plantarflexion pushoff moment. The changes in the external knee adduction moment were significantly correlated with the improvement in ankle pushoff function. Serum COMP concentration increased in response to the 0.5-h incline walking exercise with no differences in the magnitude of increment between pre- and post-intervention. Conclusions This work emphasizes the important role played by the ankle pushoff function in knee joint mechanical loading during locomotion, and may justify the inclusion of the TS MTU in prevention programs aiming to positively influence specific mechanical markers for knee osteoarthritis in the elderly. However, the study was unable to show that COMP is amenable to change in the elderly following a 14-week exercise intervention and, therefore, the physiological benefit of improved muscle function for knee cartilage requires further investigation. PMID:24905024

  4. Effect of exercise-induced enhancement of the leg-extensor muscle-tendon unit capacities on ambulatory mechanics and knee osteoarthritis markers in the elderly.

    PubMed

    Karamanidis, Kiros; Oberländer, Kai Daniel; Niehoff, Anja; Epro, Gaspar; Brüggemann, Gert-Peter

    2014-01-01

    Leg-extensor muscle weakness could be a key component in knee joint degeneration in the elderly because it may result in altered muscular control during locomotion influencing the mechanical environment within the joint. This work aimed to examine whether an exercise-induced enhancement of the triceps surae (TS) and quadriceps femoris (QF) muscle-tendon unit (MTU) capacities would affect mechanical and biological markers for knee osteoarthritis in the elderly. Twelve older women completed a 14-week TS and QF MTU exercise intervention, which had already been established as increasing muscle strength and tendon stiffness. Locomotion mechanics and serum cartilage oligomeric matrix protein (COMP) levels were examined during incline walking. MTU mechanical properties were assessed using simultaneously ultrasonography and dynamometry. Post exercise intervention, the elderly had higher TS and QF contractile strength and tendon-aponeurosis stiffness. Regarding the incline gait task, the subjects demonstrated a lower external knee adduction moment and lower knee adduction angular impulse during the stance phase post-intervention. Furthermore, post-intervention compared to pre-intervention, the elderly showed lower external hip adduction moment, but revealed higher plantarflexion pushoff moment. The changes in the external knee adduction moment were significantly correlated with the improvement in ankle pushoff function. Serum COMP concentration increased in response to the 0.5-h incline walking exercise with no differences in the magnitude of increment between pre- and post-intervention. This work emphasizes the important role played by the ankle pushoff function in knee joint mechanical loading during locomotion, and may justify the inclusion of the TS MTU in prevention programs aiming to positively influence specific mechanical markers for knee osteoarthritis in the elderly. However, the study was unable to show that COMP is amenable to change in the elderly following a 14-week exercise intervention and, therefore, the physiological benefit of improved muscle function for knee cartilage requires further investigation.

  5. Digital image correlation-aided mechanical characterization of the anteromedial and posterolateral bundles of the anterior cruciate ligament.

    PubMed

    Mallett, Kaitlyn F; Arruda, Ellen M

    2017-07-01

    The anterior cruciate ligament (ACL) is one of the most commonly injured soft tissue structures in the articular knee joint, often requiring invasive surgery for patients to restore pre-injury knee kinematics. There is a pressing need to understand the role of the ACL in knee function, in order to select proper replacements. Digital image correlation (DIC), a non-contact full field displacement measurement technique, is an established tool for evaluating non-biological materials. The application of DIC to soft tissues has been in the nascent stages, largely due to patterning challenges of such materials. The ACL is notoriously difficult to mechanically characterize, due to the complex geometry of its two bundles and their insertions. This paper examines the use of DIC to determine the tensile mechanical properties of the AM and PL bundles of ovine ACLs in a well-known loading state. Homogenous loading in the mid-substance of the bundles provides for accurate development of stress/strain curves using DIC. Animal to animal variability is reduced, and the bundles are stiffer than previously thought when tissue-level strains are accurately measured. The anterior cruciate ligament (ACL), a major stabilizing ligament of the articular knee joint, is one of the most commonly injured soft tissue structures in the knee. Often, invasive surgery is required to restore pre-injury knee kinematics, and there are several long-term consequences of ACL reconstructions, including early-onset osteoarthritis. The role of the ACL in knee stability and motion has received much attention in the biomechanics community. This paper examines the use of a non-contact full-field displacement measurement technique, digital image correlation, to determine the tensile mechanical properties of the ACL. The focus of this work is to investigate the intrinsic mechanical properties of the ACL, as new knowledge in these areas will aid clinicians in selecting ACL replacements. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  6. Can generic knee joint models improve the measurement of osteoarthritic knee kinematics during squatting activity?

    PubMed

    Clément, Julien; Dumas, Raphaël; Hagemeister, Nicola; de Guise, Jaques A

    2017-01-01

    Knee joint kinematics derived from multi-body optimisation (MBO) still requires evaluation. The objective of this study was to corroborate model-derived kinematics of osteoarthritic knees obtained using four generic knee joint models used in musculoskeletal modelling - spherical, hinge, degree-of-freedom coupling curves and parallel mechanism - against reference knee kinematics measured by stereo-radiography. Root mean square errors ranged from 0.7° to 23.4° for knee rotations and from 0.6 to 9.0 mm for knee displacements. Model-derived knee kinematics computed from generic knee joint models was inaccurate. Future developments and experiments should improve the reliability of osteoarthritic knee models in MBO and musculoskeletal modelling.

  7. Differential bacterial load on components of total knee prosthesis in patients with prosthetic joint infection.

    PubMed

    Holinka, Johannes; Pilz, Magdalena; Hirschl, Alexander M; Graninger, Wolfgang; Windhager, Reinhard; Presterl, Elisabeth

    2012-10-01

    The purpose of our study was to evaluate and quantify the bacterial adherence on different components of total knee prosthesis with the sonication culture method. Explanted components of all patients with presumptive prosthetic or implant infection were treated by sonication separately in sterile containers to dislodge the adherent bacteria from the surfaces and cultured. The bacterial load of the different knee components (femur, tibia, PE-inlay and patella) was evaluated by counting of colony-forming units (CFU) dislodged from the components surfaces using the sonication culture method. Overall, 27 patients had positive sonication cultures of explanted total knee prostheses. Microorganisms were detected from 88 of 100 explanted components. Twenty femoral components were culture positive and 7 negative, 23 tibial components as well as 23 polyethylene (PE) platforms had positive microorganism detection from the surface. Staphylococcus epidermidis adhered to the highest number of components whereas Staphylococcus aureus yielded the highest load of CFU in the sonication cultures. Although not significant, PE-inlays and tibial components were most often affected. The highest CFU count was detected in polyethylene components. The sonication culture method is a reliable method to detect bacteria from the components. Additionally, the results demonstrate that bacterial adherence is not affecting a single component of knee prosthesis only. Thus, in septic revision surgery partial prosthetic exchange or exchange of single polyethylene components alone may be not sufficient.

  8. A self-aligning knee joint for walking assistance devices.

    PubMed

    Byungjune Choi; Younbaek Lee; Jeonghun Kim; Minhyung Lee; Jongwon Lee; Se-Gon Roh; Hyundo Choi; Yong-Jae Kim; Jung-Yun Choi

    2016-08-01

    This paper presents a novel self-aligning knee mechanism for walking assistance devices for the elderly to provide physical gait assistance. Self-aligning knee joints can assist in flexion/extension motions of the knee joint and compensate the knee's transitional movements in the sagittal plane. In order to compensate the center of rotation, which moves with the flexion/extension motion of the human knee joint, a self-aligning knee joint is proposed that adds redundant degrees of freedom (i.e., 2-DoF) to the 1-DoF revolute joint. The key idea of the proposed mechanism is to decouple joint rotations and translations for use in lower-extremity wearable devices. This paper describes the mechanical design of this self-aligning knee mechanism and its implementation on a wearable robot and in preliminary experiments. The performance of the proposed mechanism is verified by simulations and experiments.

  9. Clinical and biomechanical changes following a 4-month toe-out gait modification program for people with medial knee osteoarthritis: a randomized controlled trial.

    PubMed

    Hunt, M A; Charlton, J M; Krowchuk, N M; Tse, C T F; Hatfield, G L

    2018-04-27

    To compare changes in knee pain, function, and loading following a 4-month progressive walking program with or without toe-out gait modification in people with medial tibiofemoral knee osteoarthritis. Individuals with medial knee osteoarthritis were randomized to a 4-month program to increase walking activity with (toe-out) or without (progressive walking) concomitant toe-out gait modification. The walking program was similar between the two groups, except that the gait modification group was trained to walk with 15° more toe-out. Primary outcomes included: knee joint pain (WOMAC), foot progression angles and knee joint loading during gait (knee adduction moment (KAM)). Secondary outcomes included WOMAC function, timed stair climb, and knee flexion moments during gait. Seventy-nine participants (40 in toe-out group, 39 in progressive walking group) were recruited. Intention-to-treat analysis showed no between-group differences in knee pain, function, or timed stair climb. However, the toe-out group exhibited significantly greater changes in foot progression angle (mean difference = -9.04° (indicating more toe-out), 95% CI: -11.22°, -6.86°; P < 0.001), late stance KAM (mean difference = -0.26 %BW*ht, 95% CI: -0.39 %BW*ht, -0.12 %BW*ht, P < 0.001) and KAM impulse (-0.06 %BW*ht*s, 95% CI: -0.11 %BW*ht*s, -0.01 %BW*ht*s; P = 0.031) compared to the progressive walking group at follow-up. The only between-group difference that remained at a 1-month retention assessment was foot progression angle, with greater changes in the toe-out group (mean difference = -6.78°, 95% CI: -8.82°, -4.75°; P < 0.001). Though both groups experienced improvements in self-reported pain and function, only the toe-out group experienced biomechanical improvements. NCT02019108. Copyright © 2018 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  10. A quasi-dynamic nonlinear finite element model to investigate prosthetic interface stresses during walking for trans-tibial amputees.

    PubMed

    Jia, Xiaohong; Zhang, Ming; Li, Xiaobing; Lee, Winson C C

    2005-07-01

    To predict the interface pressure between residual limb and prosthetic socket for trans-tibial amputees during walking. A quasi-dynamic finite element model was built based on the actual geometry of residual limb, internal bones and socket liner. To simulate the friction/slip boundary conditions between the skin and liner, automated surface-to-surface contact was used. Besides variable external loads and material inertia, the coupling between the large rigid displacement of knee joint and small elastic deformation of residual limb and prosthetic components were also considered. Interface pressure distribution was found to have the same profile during walking. The high pressures fall over popliteal depression, middle patella tendon, lateral tibia and medial tibia regions. Interface pressure predicted by static or quasi-dynamic analysis had the similar double-peaked waveform shape in stance phase. The consideration of inertial effects and motion of knee joint cause 210% average variation of the area between the pressure curve and the horizontal line of pressure threshold between two cases, even though there is only a small change in the peak pressure. The findings in this paper show that the coupling dynamic effects of inertial loads and knee flexion must be considered to study interface pressure between residual limb and prosthetic socket during walking.

  11. A novel hypothesis: The application of platelet-rich plasma can promote the clinical healing of white-white meniscal tears

    PubMed Central

    Wei, Li-Cheng; Gao, Shu-Guang; Xu, Mai; Jiang, Wei; Tian, Jian; Lei, Guang-Hua

    2012-01-01

    Summary The white-white tears (meniscus lesion completely in the avascular zone) are without blood supply and theoretically cannot heal. Basal research has demonstrated that menisci are unquestionably important in load bearing, load redistribution, shock absorption, joint lubrication and the stabilization of the knee joint. It has been proven that partial or all-meniscusectomy results in an accelerated degeneration of cartilage and an increased rate of early osteoarthritis. Knee surgeons must face the difficult decision of removing or, if possible, retaining the meniscus; if it is possible to retain the meniscus, surgeons must address the difficulties of meniscal healing. Some preliminary approaches have progressed to improve meniscal healing. However, the problem of promoting meniscal healing in the avascular area has not yet been resolved. The demanding nature of the approach as well as its low utility and efficacy has impeded the progress of these enhancement techniques. Platelet-rich plasma (PRP) is a platelet concentration derived from autologous blood. In recent years, PRP has been used widely in preclinical and clinical applications for bone regeneration and wound healing. Therefore, we hypothesize that the application of platelet-rich plasma for white-white meniscal tears will be a simple and novel technique of high utility in knee surgery. PMID:22847210

  12. Extraction of human gait signatures: an inverse kinematic approach using Groebner basis theory applied to gait cycle analysis

    NASA Astrophysics Data System (ADS)

    Barki, Anum; Kendricks, Kimberly; Tuttle, Ronald F.; Bunker, David J.; Borel, Christoph C.

    2013-05-01

    This research highlights the results obtained from applying the method of inverse kinematics, using Groebner basis theory, to the human gait cycle to extract and identify lower extremity gait signatures. The increased threat from suicide bombers and the force protection issues of today have motivated a team at Air Force Institute of Technology (AFIT) to research pattern recognition in the human gait cycle. The purpose of this research is to identify gait signatures of human subjects and distinguish between subjects carrying a load to those subjects without a load. These signatures were investigated via a model of the lower extremities based on motion capture observations, in particular, foot placement and the joint angles for subjects affected by carrying extra load on the body. The human gait cycle was captured and analyzed using a developed toolkit consisting of an inverse kinematic motion model of the lower extremity and a graphical user interface. Hip, knee, and ankle angles were analyzed to identify gait angle variance and range of motion. Female subjects exhibited the most knee angle variance and produced a proportional correlation between knee flexion and load carriage.

  13. Examination of factors affecting gait properties in healthy older adults: focusing on knee extension strength, visual acuity, and knee joint pain.

    PubMed

    Demura, Tomohiro; Demura, Shin-ichi; Uchiyama, Masanobu; Sugiura, Hiroki

    2014-01-01

    Gait properties change with age because of a decrease in lower limb strength and visual acuity or knee joint disorders. Gait changes commonly result from these combined factors. This study aimed to examine the effects of knee extension strength, visual acuity, and knee joint pain on gait properties of for 181 healthy female older adults (age: 76.1 (5.7) years). Walking speed, cadence, stance time, swing time, double support time, step length, step width, walking angle, and toe angle were selected as gait parameters. Knee extension strength was measured by isometric dynamometry; and decreased visual acuity and knee joint pain were evaluated by subjective judgment whether or not such factors created a hindrance during walking. Among older adults without vision problems and knee joint pain that affected walking, those with superior knee extension strength had significantly greater walking speed and step length than those with inferior knee extension strength (P < .05). Persons with visual acuity problems had higher cadence and shorter stance time. In addition, persons with pain in both knees showed slower walking speed and longer stance time and double support time. A decrease of knee extension strength and visual acuity and knee joint pain are factors affecting gait in the female older adults. Decreased knee extension strength and knee joint pain mainly affect respective distance and time parameters of the gait.

  14. Behavioral effect of knee joint motion on body's center of mass during human quiet standing.

    PubMed

    Yamamoto, Akio; Sasagawa, Shun; Oba, Naoko; Nakazawa, Kimitaka

    2015-01-01

    The balance control mechanism during upright standing has often been investigated using single- or double-link inverted pendulum models, involving the ankle joint only or both the ankle and hip joints, respectively. Several studies, however, have reported that knee joint motion during quiet standing cannot be ignored. This study aimed to investigate the degree to which knee joint motion contributes to the center of mass (COM) kinematics during quiet standing. Eight healthy adults were asked to stand quietly for 30s on a force platform. Angular displacements and accelerations of the ankle, knee, and hip joints were calculated from kinematic data obtained by a motion capture system. We found that the amplitude of the angular acceleration was smallest in the ankle joint and largest in the hip joint (ankle < knee < hip). These angular accelerations were then substituted into three biomechanical models with or without the knee joint to estimate COM acceleration in the anterior-posterior direction. Although the "without-knee" models greatly overestimated the COM acceleration, the COM acceleration estimated by the "with-knee" model was similar to the actual acceleration obtained from force platform measurement. These results indicate substantial effects of knee joint motion on the COM kinematics during quiet standing. We suggest that investigations based on the multi-joint model, including the knee joint, are required to reveal the physiologically plausible balance control mechanism implemented by the central nervous system. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. The saline load test of the knee redefined: a test to detect traumatic arthrotomies and rule out periarticular wounds not requiring surgical intervention.

    PubMed

    Konda, Sanjit R; Howard, Daniel; Davidovitch, Roy I; Egol, Kenneth A

    2013-09-01

    To describe the use of the saline load test (SLT) using a new definition that more adequately characterizes its use in the emergency department (ED) setting. Retrospective review. Level I trauma center. Fifty consecutive patients who underwent an SLT of the knee in the ED and had a minimum of 14 days follow-up. Saline Load Test. Positive traumatic arthrotomy of the knee (+TAK) defined as operating room (OR) confirmation of an arthrotomy (assumed to develop a septic knee) or -SLT with follow-up revealing a septic knee. Periarticular wound equivalent to no traumatic arthrotomy of the knee [pw = (-TAK)] defined as OR evaluation revealing no arthrotomy (assumed not to develop a septic knee) or -SLT whose follow-up revealed no septic knee. Development of a septic knee was considered the gold standard for determining true positives/negatives and false positives/negatives. The mean wound size was 3.9 ± 4.3 cm and the mean saline load volume was 74.9 ± 28.2 cm. There were 19 +SLTs of which there were 16 +TAK and 3 pw = (-TAK). The 3 pw = (-TAK) in the +SLT group were evaluated in the OR where inspection of the joint capsule revealed the absence of a traumatic arthrotomy. There were 31 -SLTs of which there were 1 +TAK and 30 pw = (-TAK). The SLT has a sensitivity of 94% and a specificity of 91% for detecting +TAKs and ruling out periarticular wounds not requiring surgical intervention [pw = (-TAK)]. The false-positive rate of the SLT to detect +TAK is 9%. Using +TAK and pw = (-TAK) as the newly defined measures of the SLT, we report the sensitivity (94%) and specificity (91%) of the SLT in the ED setting while still maintaining the clinical relevancy of the test. Based on a small sample size, knees with small periarticular wounds and a -SLT and no other radiographic or clinical evidence of an arthrotomy appear to have an infection rate of 0% with nonoperative management. Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  16. [The effect of different types of sports and athletes' age on the pathological changes of the musculoskeletal system].

    PubMed

    Achkasov, E E; Puzin, S N; Litvinenko, A S; Kurshev, V V; Bezuglov, E N

    2014-01-01

    Our aim was to determine the most common musculoskeletal diseases, depending on the type of sports and athletes' age. The results of examination of 976 athletes aged from 16 to 42 years (average age - 28,9±2,3) with musculoskeletal diseases were analyzed. Medical diagnostic procedures included clinical, laboratory, instrumental (radiography, magnetic resonance imaging, ultrasound) investigations and functional testing (goniometry, manual muscle testing). Majority of patients were diagnosed to have diseases of the knee (17.9%) and ankle joints (11.3%), the heel bone (12.9%), Achilles tendon (10.2%), post-traumatic musculoskeletal diseases (16.2%), degenerative-dystrophic diseases of the spine (12.8%). In the young age group (16 to 20 years) post-traumatic disorders were most common. In the middle-age group (21 to 30 years) along with post-traumatic disorders diseases of the knee frequently occurred. For athletes over 30 years old, along with diseases of the knee spinal diseases were found to occur 2-3 times more frequently in comparison with other age groups. Injuries which are more common for different types of sports were identified: acute traumas - competitive sports, diseases of the calcaneus - sports with running and jumping (athletics, volleyball, soccer), disease of ankle joints - sport with sharp change in movement direction (hockey, figure skating), disease of the knee - sports with high load of the knee joint (figure skating, gymnastics, volleyball, diseases of bones and joints of the upper extremity - tennis, disease of spine - weightlifting. pathological changes in the musculoskeletal system depend on the type of sports and the age of athletes. The combination of age and risk factors associated with type of sport increases the possibility of development of these diseases of the musculoskeletal system.

  17. Pathophysiology of obesity on knee joint homeostasis: contributions of the infrapatellar fat pad.

    PubMed

    Santangelo, Kelly S; Radakovich, Lauren B; Fouts, Josie; Foster, Michelle T

    2016-05-01

    Osteoarthritis (OA) is a debilitating condition characterized by inflammation, breakdown, and consequent loss of cartilage of the joints. Epidemiological studies indicate obesity is an important risk factor involved in OA initiation and progression. Traditional views propose OA to be a biomechanical consequence of excess weight on weight-bearing joints; however, emerging data demonstrates that systemic and local factors released from white adipose depots play a role. Hence, current views characterize OA as a condition exacerbated by a metabolic link related to adipose tissue, and not solely related to redistributed/altered weight load. Factors demonstrated to influence cartilage and bone homeostasis include adipocyte-derived hormones ("adipokines") and adipose depot released cytokines. Epidemiological studies demonstrate a positive relation between systemic circulating cytokines, leptin, and resistin with OA types, while the association with adiponectin is controversial. Local factors in joints have also been shown to play a role in OA. In particular, this includes the knee, a weight-bearing joint that encloses a relatively large adipose depot, the infrapatellar fat pad (IFP), which serves as a source of local inflammatory factors. This review summarizes the relation of obesity and OA as it specifically relates to the IFP and other integral supporting structures. Overall, studies support the concept that metabolic effects associated with systemic obesity also extend to the IFP, which promotes inflammation, pain, and cartilage destruction within the local knee joint environment, thus contributing to development and progression of OA.

  18. Oxygenation, local muscle oxygen consumption and joint specific power in cycling: the effect of cadence at a constant external work rate.

    PubMed

    Skovereng, Knut; Ettema, Gertjan; van Beekvelt, Mireille C P

    2016-06-01

    The present study investigates the effect of cadence on joint specific power and oxygenation and local muscle oxygen consumption in the vastus lateralis and vastus medialis in addition to the relationship between joint specific power and local muscle oxygen consumption (mVO2). Seventeen recreationally active cyclists performed 6 stages of constant load cycling using cadences of 60, 70, 80, 90, 100 and 110 rpm. Joint specific power was calculated using inverse dynamics and mVO2 and oxygenation were measured using near-infrared spectroscopy. Increasing cadence led to increased knee joint power and decreased hip joint power while the ankle joint was unaffected. Increasing cadence also led to an increased deoxygenation in both the vastus lateralis and vastus medialis. Vastus lateralis mVO2 increased when cadence was increased. No effect of cadence was found for vastus medialis mVO2. This study demonstrates a different effect of cadence on the mVO2 of the vastus lateralis and vastus medialis. The combined mVO2 of the vastus lateralis and medialis showed a linear increase with increasing knee joint specific power, demonstrating that the muscles combined related to power generated over the joint.

  19. Biomechanical consequences of a tear of the posterior root of the medial meniscus. Surgical technique.

    PubMed

    Harner, Christopher D; Mauro, Craig S; Lesniak, Bryson P; Romanowski, James R

    2009-10-01

    Tears of the posterior root of the medial meniscus are becoming increasingly recognized. They can cause rapidly progressive arthritis, yet their biomechanical effects are not understood. The goal of this study was to determine the effects of posterior root tears of the medial meniscus and their repairs on tibiofemoral joint contact pressure and kinematics. Nine fresh-frozen cadaver knees were used. An axial load of 1000 N was applied with a custom testing jig at each of four knee-flexion angles: 0 degrees , 30 degrees , 60 degrees , and 90 degrees . The knees were otherwise unconstrained. Four conditions were tested: (1) intact, (2) a posterior root tear of the medial meniscus, (3) a repaired posterior root tear, and (4) a total medial meniscectomy. Fuji pressure-sensitive film was used to record the contact pressure and area for each testing condition. Kinematic data were obtained by using a robotic arm to record the position of the knees for each loading condition. Three-dimensional knee kinematics were analyzed with custom programs with use of previously described transformations. The measured variables were axial rotation, varus angulation, lateral translation, and anterior translation. In the medial compartment, a posterior root tear of the medial meniscus caused a 25% increase in peak contact pressure compared with that found in the intact condition (p < 0.001). Repair restored the peak contact pressure to normal. No difference was detected between the peak contact pressure after the total medial meniscectomy and that associated with the root tear. The peak contact pressure in the lateral compartment after the total medial meniscectomy was up to 13% greater than that for all other conditions (p = 0.026). Significant increases in external rotation and lateral tibial translation, compared with the values in the intact knee, were observed in association with the posterior root tear (2.98 degrees and 0.84 mm, respectively) and the meniscectomy (4.45 degrees and 0.80 mm, respectively), and these increases were corrected by the repair. This study demonstrated significant changes in contact pressure and knee joint kinematics due to a posterior root tear of the medial meniscus. Root repair was successful in restoring joint biomechanics to within normal conditions.

  20. Biomechanical consequences of a tear of the posterior root of the medial meniscus. Similar to total meniscectomy.

    PubMed

    Allaire, Robert; Muriuki, Muturi; Gilbertson, Lars; Harner, Christopher D

    2008-09-01

    Tears of the posterior root of the medial meniscus are becoming increasingly recognized. They can cause rapidly progressive arthritis, yet their biomechanical effects are not understood. The goal of this study was to determine the effects of posterior root tears of the medial meniscus and their repairs on tibiofemoral joint contact pressure and kinematics. Nine fresh-frozen cadaver knees were used. An axial load of 1000 N was applied with a custom testing jig at each of four knee-flexion angles: 0 degrees, 30 degrees, 60 degrees, and 90 degrees. The knees were otherwise unconstrained. Four conditions were tested: (1) intact, (2) a posterior root tear of the medial meniscus, (3) a repaired posterior root tear, and (4) a total medial meniscectomy. Fuji pressure-sensitive film was used to record the contact pressure and area for each testing condition. Kinematic data were obtained by using a robotic arm to record the position of the knees for each loading condition. Three-dimensional knee kinematics were analyzed with custom programs with use of previously described transformations. The measured variables were axial rotation, varus angulation, lateral translation, and anterior translation. In the medial compartment, a posterior root tear of the medial meniscus caused a 25% increase in peak contact pressure compared with that found in the intact condition (p < 0.001). Repair restored the peak contact pressure to normal. No difference was detected between the peak contact pressure after the total medial meniscectomy and that associated with the root tear. The peak contact pressure in the lateral compartment after the total medial meniscectomy was up to 13% greater than that for all other conditions (p = 0.026). Significant increases in external rotation and lateral tibial translation, compared with the values in the intact knee, were observed in association with the posterior root tear (2.98 degrees and 0.84 mm, respectively) and the meniscectomy (4.45 degrees and 0.80 mm, respectively), and these increases were corrected by the repair. This study demonstrated significant changes in contact pressure and knee joint kinematics due to a posterior root tear of the medial meniscus. Root repair was successful in restoring joint biomechanics to within normal conditions.

  1. The influence of motion control shoes on the running gait of mature and young females.

    PubMed

    Lilley, Kim; Stiles, Vicky; Dixon, Sharon

    2013-03-01

    This study compared the running gait of mature and young females, and investigated the effect of a motion control shoe. First, it was hypothesised that in a neutral shoe, mature females would display significantly greater rearfoot eversion, knee internal rotation and external adductor moments when compared to a younger group. Secondly, the motion control shoe would reduce rearfoot eversion and knee internal rotation in both groups. Thirdly it was hypothesised that the motion control shoe would increase knee external adductor moment, through an increase in knee varus and moment arm. 15 mature (40-60 years) and 15 young (18-25 years) females performed 10 running trials at 3.5ms(-1)±5% over a force platform. Two shoes were tested, the Adidas Supernova Glide (neutral), and the Adidas Supernova Sequence (motion control). Ankle and knee joint dynamics were analysed for the right leg, and the mean of ten trials was calculated. Joint moments were calculated using inverse dynamics. In the neutral condition, mature females presented greater peak rearfoot eversion, knee internal rotation, and external adductor moments than young females (p<0.05). A motion control shoe significantly reduced peak rearfoot eversion and knee internal rotation among both groups (p<0.05). No between shoe differences in knee external adductor moment were observed. A motion control shoe is recommended to reduce risk of injury associated with rearfoot eversion and knee internal rotation in mature females. However since the knee external adductor moment is a variable commonly associated with medial knee loading it is suggested that alternative design features are required to influence this moment. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Knee joint motion and muscle activation patterns are altered during gait in individuals with moderate hip osteoarthritis compared to asymptomatic cohort.

    PubMed

    Rutherford, Derek; Moreside, Janice; Wong, Ivan

    2015-07-01

    Knee replacements are common after hip replacement for end stage osteoarthritis. Whether abnormal knee mechanics exist in moderate hip osteoarthritis remains undetermined and has implications for understanding early osteoarthritis joint mechanics. The purpose of this study was to determine whether three-dimensional (3D) knee motion and muscle activation patterns in individuals with moderate hip osteoarthritis differ from an asymptomatic cohort and whether these features differ between contra- and ipsilateral knees. 3D motions and medial and lateral quadriceps and hamstring surface electromyography were recorded on 20 asymptomatic individuals and 20 individuals with moderate hip osteoarthritis during treadmill walking, using standardized collection and processing procedures. Principal component analysis was used to derive electromyographic amplitude and temporal waveform features. 3D stance-phase range of motion was calculated. A 2-factor repeated analysis of variance determined significant within-group leg and muscle differences. Student's t-tests identified between group differences, with Bonferroni corrections where applicable (α=0.05). Lower sagittal plane motion between early and mid/late stance (5°, P=0.004, effect size: 0.96) and greater mid-stance quadriceps activity was found in the osteoarthritis group (P=0.01). Compared to the ipsilateral knee, a borderline significant increase in mid-stance hamstring activity was found in the contra-lateral knee of the hip osteoarthritis group (P=0.018). Bilateral knee mechanics were altered, suggesting potentially increased loads and knee muscle fatigue. There was no indication that one knee is more susceptible to osteoarthritis than the other, thus clinicians should include bilateral knee analysis when treating patients with hip osteoarthritis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Joint Angular Velocity in Spastic Gait and the Influence of Muscle-Tendon Lengthening*

    PubMed Central

    GRANATA, KEVIN P.; ABEL, MARK F.; DAMIANO, DIANE L.

    2006-01-01

    Background Joint angular velocity (the rate of flexion and extension of a joint) is related to the dynamics of muscle activation and force generation during walking. Therefore, the goal of this research was to examine the joint angular velocity in normal and spastic gait and changes resulting from muscle-tendon lengthening (recession and tenotomy) in patients who have spastic cerebral palsy. Methods The gait patterns of forty patients who had been diagnosed with spastic cerebral palsy (mean age, 8.3 years; range, 3.7 to 14.8 years) and of seventy-three age-matched, normally developing subjects were evaluated with three-dimensional motion analysis and electromyography. The patients who had cerebral palsy were evaluated before muscle-tendon lengthening and nine months after treatment. Results The gait patterns of the patients who had cerebral palsy were characterized by increased flexion of the knee in the stance phase, premature plantar flexion of the ankle, and reduced joint angular velocities compared with the patterns of the normally developing subjects. Even though muscle-tendon lengthening altered sagittal joint angles in gait, the joint angular velocities were generally unchanged at the hip and knee. Only the ankle demonstrated modified angular velocities, including reduced dorsiflexion velocity at foot-strike and improved dorsiflexion velocity through midstance, after treatment. Electromyographic changes included reduced amplitude of the gastrocnemius-soleus during the loading phase and decreased knee coactivity (the ratio of quadriceps and hamstring activation) at toe-off. Principal component analyses showed that, compared with joint-angle data, joint angular velocity was better able to discriminate between the gait patterns of the normal and cerebral palsy groups. Conclusions This study showed that muscle-tendon lengthening corrects biomechanical alignment as reflected by changes in sagittal joint angles. However, joint angular velocity and electromyographic data suggest that the underlying neural input remains largely unchanged at the hip and knee. Conversely, electromyographic changes and changes in velocity in the ankle indicate that the activation pattern of the gastrocnemius-soleus complex in response to stretch was altered by recession of the complex. PMID:10682726

  4. Crank inertial load has little effect on steady-state pedaling coordination.

    PubMed

    Fregly, B J; Zajac, F E; Dairaghi, C A

    1996-12-01

    Inertial load can affect the control of a dynamic system whenever parts of the system are accelerated or decelerated. During steady-state pedaling, because within-cycle variations in crank angular acceleration still exist, the amount of crank inertia present (which varies widely with road-riding gear ratio) may affect the within-cycle coordination of muscles. However, the effect of inertial load on steady-state pedaling coordination is almost always assumed to be negligible, since the net mechanical energy per cycle developed by muscles only depends on the constant cadence and workload. This study test the hypothesis that under steady-state conditions, the net joint torques produced by muscles at the hip, knee, and ankle are unaffected by crank inertial load. To perform the investigation, we constructed a pedaling apparatus which could emulate the low inertial load of a standard ergometer or the high inertial load of a road bicycle in high gear. Crank angle and bilateral pedal force and angle data were collected from ten subjects instructed to pedal steadily (i.e., constant speed across cycles) and smoothly (i.e., constant speed within a cycle) against both inertias at a constant workload. Virtually no statistically significant changes were found in the net hip and knee muscle joint torques calculated from an inverse dynamics analysis. Though the net ankle muscle joint torque, as well as the one- and two-legged crank torque, showed statistically significant increases at the higher inertia, the changes were small. In contrast, large statistically significant reductions were found in crank kinematic variability both within a cycle and between cycles (i.e., cadence), primarily because a larger inertial load means a slower crank dynamic response. Nonetheless, the reduction in cadence variability was somewhat attenuated by a large statistically significant increase in one-legged crank torque variability. We suggest, therefore, that muscle coordination during steady-state pedaling is largely unaffected, though less well regulated, when crank inertial load is increased.

  5. Uphill walking: Biomechanical demand on the lower extremities of obese adolescents.

    PubMed

    Strutzenberger, Gerda; Alexander, Nathalie; Bamboschek, Dominik; Claas, Elisabeth; Langhof, Helmut; Schwameder, Hermann

    2017-05-01

    The number of obesity prevalence in adolescents is still increasing. Obesity treatment programs typically include physical activity with walking being recommended as appropriate activity, but limited information exists on the demand uphill walking places on the joint loading and power of obese adolescents. Therefore, the purpose of this study was to investigate the effect of different inclinations on step characteristics, sagittal and frontal joint angles, joint moments and joint power of obese adolescents in comparison to their normal-weight peers. Eleven obese (14.5±1.41 years, BMI: 31.1±3.5kg/m 2 ) and eleven normal-weight adolescents (14.3±1.86 years, BMI: 19.0±1.7kg/m 2 ) walked with 1.11m/s on a ramp with two imbedded force plates (AMTI, 1000Hz) at three inclinations (level, 6°, 12°). Kinematic data were collected via an infrared-camera motion system (Vicon, 250Hz). The two-way (inclination, group) ANOVA indicated a significant effect of inclination on almost all variables analysed, with the hip joint being the most affected by inclination, followed by the knee and ankle joint. The obese participants additionally spent less time in swing phase, walked with an increased knee flexion and valgus angle and an increased peak hip flexion and adduction moment. Hip joint power of obese adolescents was especially in the steepest inclination significantly increased compared to their normal-weight peers. Obese adolescents demonstrate increased joint loading compared to their normal-weight peers and in combination with a musculoskeletal malalignment they might be prone to an increased overuse injury risk. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Prophylactic knee bracing alters lower-limb muscle forces during a double-leg drop landing.

    PubMed

    Ewing, Katie A; Fernandez, Justin W; Begg, Rezaul K; Galea, Mary P; Lee, Peter V S

    2016-10-03

    Anterior cruciate ligament (ACL) injury can be a painful, debilitating and costly consequence of participating in sporting activities. Prophylactic knee bracing aims to reduce the number and severity of ACL injury, which commonly occurs during landing maneuvers and is more prevalent in female athletes, but a consensus on the effectiveness of prophylactic knee braces has not been established. The lower-limb muscles are believed to play an important role in stabilizing the knee joint. The purpose of this study was to investigate the changes in lower-limb muscle function with prophylactic knee bracing in male and female athletes during landing. Fifteen recreational athletes performed double-leg drop landing tasks from 0.30m and 0.60m with and without a prophylactic knee brace. Motion analysis data were used to create subject-specific musculoskeletal models in OpenSim. Static optimization was performed to calculate the lower-limb muscle forces. A linear mixed model determined that the hamstrings and vasti muscles produced significantly greater flexion and extension torques, respectively, and greater peak muscle forces with bracing. No differences in the timings of peak muscle forces were observed. These findings suggest that prophylactic knee bracing may help to provide stability to the knee joint by increasing the active stiffness of the hamstrings and vasti muscles later in the landing phase rather than by altering the timing of muscle forces. Further studies are necessary to quantify whether prophylactic knee bracing can reduce the load placed on the ACL during intense dynamic movements. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Assessing the Relative Contributions of Active Ankle and Knee Assistance to the Walking Mechanics of Transfemoral Amputees Using a Powered Prosthesis

    PubMed Central

    Simon, Ann M.; Hargrove, Levi J.

    2016-01-01

    Powered knee-ankle prostheses are capable of providing net-positive mechanical energy to amputees. Yet, there are limitless ways to deliver this energy throughout the gait cycle. It remains largely unknown how different combinations of active knee and ankle assistance affect the walking mechanics of transfemoral amputees. This study assessed the relative contributions of stance phase knee swing initiation, increasing ankle stiffness and powered plantarflexion as three unilateral transfemoral amputees walked overground at their self-selected walking speed. Five combinations of knee and ankle conditions were evaluated regarding the kinematics and kinetics of the amputated and intact legs using repeated measures analyses of variance. We found eliminating active knee swing initiation or powered plantarflexion was linked to increased compensations of the ipsilateral hip joint during the subsequent swing phase. The elimination of knee swing initiation or powered plantarflexion also led to reduced braking ground reaction forces of the amputated and intact legs, and influenced both sagittal and frontal plane loading of the intact knee joint. Gradually increasing prosthetic ankle stiffness influenced the shape of the prosthetic ankle plantarflexion moment, more closely mirroring the intact ankle moment. Increasing ankle stiffness also corresponded to increased prosthetic ankle power generation (despite a similar maximum stiffness value across conditions) and increased braking ground reaction forces of the amputated leg. These findings further our understanding of how to deliver assistance with powered knee-ankle prostheses and the compensations that occur when specific aspects of assistance are added/removed. PMID:26807889

  8. Frontal plane stability following UKA in a biomechanical study.

    PubMed

    Heyse, Thomas J; Tucker, Scott M; Rajak, Yogesh; Kia, Mohammad; Lipman, Joseph D; Imhauser, Carl W; Westrich, Geoffrey H

    2015-06-01

    Function and kinematics following unicondylar knee arthroplasty (UKA) have been reported to be close to the native knee. Gait, stair climbing and activities of daily living expose the knee joint to a combination of varus and valgus moments. Replacement of the medial compartment via UKA is likely to change the physiologic knee stability and its ability to respond to varus and valgus moments. It was hypothesized that UKA implantation would stiffen the knee and decrease range of motion in the frontal plane. Six fresh frozen cadaver knees were prepared and mounted in a six-degrees-of-freedom robot. An axial load of 200 N was applied with the knee in 15°, 45° and 90° of flexion. Varus and valgus moments were added, respectively, before and after implantation of medial UKA. Tests were than redone with a thicker polyethylene inlay to simulate overstuffing of the medial compartment. Range of motion in the frontal plane and the tibial response to moments were recorded via the industrial robot. The range of motion in the frontal plane was decreased with both, balanced and overstuffed UKA and shifted towards valgus. When exposed to valgus moments, knees following UKA were stiffer in comparison with the native knee. The effect was even more pronounced with medial overstuffing. In UKA, the compressive anatomy is replaced by much stiffer components. This lack of medial compression and relative overstuffing leads to a tighter medial collateral ligament. This drives the trend towards a stiffer joint as documented by a decrease in frontal plane range of motion. Overstuffing should strictly be avoided when performing UKA.

  9. A Combined Experimental and Computational Approach to Subject-Specific Analysis of Knee Joint Laxity

    PubMed Central

    Harris, Michael D.; Cyr, Adam J.; Ali, Azhar A.; Fitzpatrick, Clare K.; Rullkoetter, Paul J.; Maletsky, Lorin P.; Shelburne, Kevin B.

    2016-01-01

    Modeling complex knee biomechanics is a continual challenge, which has resulted in many models of varying levels of quality, complexity, and validation. Beyond modeling healthy knees, accurately mimicking pathologic knee mechanics, such as after cruciate rupture or meniscectomy, is difficult. Experimental tests of knee laxity can provide important information about ligament engagement and overall contributions to knee stability for development of subject-specific models to accurately simulate knee motion and loading. Our objective was to provide combined experimental tests and finite-element (FE) models of natural knee laxity that are subject-specific, have one-to-one experiment to model calibration, simulate ligament engagement in agreement with literature, and are adaptable for a variety of biomechanical investigations (e.g., cartilage contact, ligament strain, in vivo kinematics). Calibration involved perturbing ligament stiffness, initial ligament strain, and attachment location until model-predicted kinematics and ligament engagement matched experimental reports. Errors between model-predicted and experimental kinematics averaged <2 deg during varus–valgus (VV) rotations, <6 deg during internal–external (IE) rotations, and <3 mm of translation during anterior–posterior (AP) displacements. Engagement of the individual ligaments agreed with literature descriptions. These results demonstrate the ability of our constraint models to be customized for multiple individuals and simultaneously call attention to the need to verify that ligament engagement is in good general agreement with literature. To facilitate further investigations of subject-specific or population based knee joint biomechanics, data collected during the experimental and modeling phases of this study are available for download by the research community. PMID:27306137

  10. The volume of the human knee joint.

    PubMed

    Matziolis, Georg; Roehner, Eric; Windisch, Christoph; Wagner, Andreas

    2015-10-01

    Despite its clinical relevance, particularly in septic knee surgery, the volume of the human knee joint has not been established to date. Therefore, the objective of this study was to determine knee joint volume and whether or not it is dependent on sex or body height. Sixty-one consecutive patients (joints) who were due to undergo endoprosthetic joint replacement were enrolled in this prospective study. During the operation, the joint volume was determined by injecting saline solution until a pressure of 200 mmHg was achieved in the joint. The average volume of all knee joints was 131 ± 53 (40-290) ml. The volume was not found to be dependent on sex, but it was dependent on the patients' height (R = 0.312, p = 0.014). This enabled an estimation of the joint volume according to V = 1.6 height - 135. The considerable inter-individual variance of the knee joint volume would suggest that it should be determined or at least estimated according to body height if the joint volume has consequences for the diagnostics or therapy of knee disorders.

  11. Knee joint distraction compared with high tibial osteotomy: a randomized controlled trial.

    PubMed

    van der Woude, J A D; Wiegant, K; van Heerwaarden, R J; Spruijt, S; van Roermund, P M; Custers, R J H; Mastbergen, S C; Lafeber, F P J G

    2017-03-01

    Both, knee joint distraction as a relatively new approach and valgus-producing opening-wedge high tibial osteotomy (HTO), are knee-preserving treatments for knee osteoarthritis (OA). The efficacy of knee joint distraction compared to HTO has not been reported. Sixty-nine patients with medial knee joint OA with a varus axis deviation of <10° were randomized to either knee joint distraction (n = 23) or HTO (n = 46). Questionnaires were assessed at baseline and 3, 6, and 12 months. Joint space width (JSW) as a surrogate measure for cartilage thickness was determined on standardized semi-flexed radiographs at baseline and 1-year follow-up. All patient-reported outcome measures (PROMS) improved significantly over 1 year (at 1 year p < 0.02) in both groups. At 1 year, the HTO group showed slightly greater improvement in 4 of the 16 PROMS (p < 0.05). The minimum medial compartment JSW increased 0.8 ± 1.0 mm in the knee joint distraction group (p = 0.001) and 0.4 ± 0.5 mm in the HTO group (p < 0.001), with minimum JSW improvement in favour of knee joint distraction (p = 0.05). The lateral compartment showed a small increase in the knee joint distraction group and a small decrease in the HTO group, leading to a significant increase in mean JSW for knee joint distraction only (p < 0.02). Cartilaginous repair activity, as indicated by JSW, and clinical outcome improvement occurred with both, knee joint distraction and HTO. These findings suggest that knee joint distraction may be an alternative therapy for medial compartmental OA with a limited mechanical leg malalignment. Randomized controlled trial, Level I.

  12. 21 CFR 888.3490 - Knee joint femorotibial metal/composite non-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Knee joint femorotibial metal/composite non... § 888.3490 Knee joint femorotibial metal/composite non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/composite non-constrained cemented prosthesis is a device...

  13. 21 CFR 888.3500 - Knee joint femorotibial metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Knee joint femorotibial metal/composite semi... § 888.3500 Knee joint femorotibial metal/composite semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/composite semi-constrained cemented prosthesis is a two-part...

  14. 21 CFR 888.3550 - Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Knee joint patellofemorotibial polymer/metal/metal... § 888.3550 Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis. (a) Identification. A knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis is a device...

  15. 21 CFR 888.3510 - Knee joint femorotibial metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/polymer constrained... Knee joint femorotibial metal/polymer constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer constrained cemented prosthesis is a device intended to be implanted to replace part...

  16. 21 CFR 888.3565 - Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellofemorotibial metal/polymer... Devices § 888.3565 Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis. (a) Identification. A knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis is a device...

  17. 21 CFR 888.3530 - Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/polymer semi... § 888.3530 Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer semi-constrained cemented prosthesis is a device intended...

  18. 21 CFR 888.3540 - Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellofemoral polymer/metal semi... § 888.3540 Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis. (a) Identification. A knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis is a two-part...

  19. 21 CFR 888.3550 - Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellofemorotibial polymer/metal/metal... § 888.3550 Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis. (a) Identification. A knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis is a device...

  20. 21 CFR 888.3530 - Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Knee joint femorotibial metal/polymer semi... § 888.3530 Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer semi-constrained cemented prosthesis is a device intended...

  1. 21 CFR 888.3500 - Knee joint femorotibial metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/composite semi... § 888.3500 Knee joint femorotibial metal/composite semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/composite semi-constrained cemented prosthesis is a two-part...

  2. 21 CFR 888.3490 - Knee joint femorotibial metal/composite non-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/composite non... § 888.3490 Knee joint femorotibial metal/composite non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/composite non-constrained cemented prosthesis is a device...

  3. 21 CFR 888.3565 - Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Knee joint patellofemorotibial metal/polymer... Devices § 888.3565 Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis. (a) Identification. A knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis is a device...

  4. 21 CFR 888.3565 - Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Knee joint patellofemorotibial metal/polymer... Devices § 888.3565 Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis. (a) Identification. A knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis is a device...

  5. 21 CFR 888.3550 - Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Knee joint patellofemorotibial polymer/metal/metal... § 888.3550 Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis. (a) Identification. A knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis is a device...

  6. 21 CFR 888.3530 - Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Knee joint femorotibial metal/polymer semi... § 888.3530 Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer semi-constrained cemented prosthesis is a device intended...

  7. 21 CFR 888.3530 - Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Knee joint femorotibial metal/polymer semi... § 888.3530 Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer semi-constrained cemented prosthesis is a device intended...

  8. 21 CFR 888.3530 - Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Knee joint femorotibial metal/polymer semi... § 888.3530 Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer semi-constrained cemented prosthesis is a device intended...

  9. 21 CFR 888.3565 - Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Knee joint patellofemorotibial metal/polymer... Devices § 888.3565 Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis. (a) Identification. A knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis is a device...

  10. 21 CFR 888.3550 - Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Knee joint patellofemorotibial polymer/metal/metal... § 888.3550 Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis. (a) Identification. A knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis is a device...

  11. 21 CFR 888.3550 - Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Knee joint patellofemorotibial polymer/metal/metal... § 888.3550 Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis. (a) Identification. A knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis is a device...

  12. Unloading shoes for osteoarthritis of the knee: protocol for the SHARK randomised controlled trial

    PubMed Central

    2014-01-01

    Background Knee osteoarthritis (OA) is a common and disabling condition. Abnormalities in knee loading play an important role in disease pathogenesis, yet there are few non-surgical treatments for knee OA capable of reducing knee load. This two-arm randomised controlled trial is investigating the efficacy of specially-designed unloading shoes for the treatment of symptoms in people with knee OA. Methods/Design 164 people with symptomatic medial tibiofemoral joint OA will be recruited from the community and randomly allocated to receive either unloading shoes or control shoes. Unloading shoes have a specially-designed triple-density midsole where the medial side is softer than normal and the lateral side harder as well as a lateral wedge between the sole and sock-liner. Control shoes are standard athletic shoes and do not contain these features. Participants will be blinded to shoe allocation and will be instructed to wear the shoes as much as possible every day for 6 months, for a minimum of 4 hours per day. The primary outcomes are knee pain (numerical rating scale) and self-reported physical function (Western Ontario and McMaster Universities Osteoarthritis Index) measured at baseline and 6 months. Secondary outcomes include additional measures of knee pain, knee stiffness, participant global ratings of change in symptoms, quality-of-life and physical activity. Conclusions The findings from this study will help determine whether specially-designed unloading shoes are efficacious in the management of knee OA. Trial registration Australian New Zealand Clinical Trials Registry reference: ACTRN12613000851763. PMID:24555418

  13. Manipulated Changes in Limb Mass and Rotational Inertia in Trotting Dogs (Canis lupus familiaris) and Their Effect on Limb Kinematics.

    PubMed

    Kilbourne, Brandon M; Carrier, David R

    2016-12-01

    While the mass distribution of limbs is known to influence the metabolic energy consumed during locomotion, it remains unknown how the mass distribution of limbs may influence overall limb kinematics and whether the influence of limb mass distribution on limb kinematics differs between fore- and hindlimbs. To examine limb mass distribution's influence upon fore- and hindlimb kinematics, temporal stride parameters and swing phase joint kinematics were recorded from four dogs trotting on a treadmill with 0.5% and 1.0% body mass added to each limb, forelimbs alone, and hindlimbs alone, as well as with no added mass. Under all loading conditions, stride period did not differ between fore- and hindlimbs; however, forelimbs exhibited greater duty factors and stance durations, whereas hindlimbs exhibited greater swing durations, which may be related to the hindlimb's greater mass. Changes in forelimb joint and hip range of motion (RoM), flexion, and extension were subject to a high amount of kinematic plasticity among dogs. In contrast, for the knee and ankle, distally loading all four limbs or hindlimbs alone substantially increased joint RoM and flexion. Increased flexion of the knee and ankle has the potential to reduce the hindlimb's rotational inertia during swing phase. The differing response of fore- and hindlimbs with regard to joint kinematics is likely due to differences in their mass and mass distribution and differences in the physiological traits of fore- and hindlimb protractors and joint flexors. © 2017 Wiley Periodicals, Inc.

  14. Knee Joint Kinetics in Relation to Commonly Prescribed Squat Loads and Depths

    PubMed Central

    Cotter, Joshua A.; Chaudhari, Ait M.; Jamison, Steve T.; Devor, Steven T.

    2014-01-01

    Controversy exists regarding the safety and performance benefits of performing the squat exercise to depths beyond 90° of knee flexion. Our aim was to compare the net peak external knee flexion moments (pEKFM) experienced over typical ranges of squat loads and depths. Sixteen recreationally trained males (n = 16; 22.7 ± 1.1 yrs; 85.4 ± 2.1 kg; 177.6 ± 0.96 cm; mean ± SEM) with no previous lower limb surgeries or other orthopedic issues and at least one year of consistent resistance training experience while utilizing the squat exercise performed single repetition squat trials in a random order at squat depths of above parallel, parallel, and below parallel. Less than one week before testing, one repetition maximum (1RM) values were found for each squat depth. Subsequent testing required subjects to perform squats at the three depths with three different loads: unloaded, 50% 1RM, and 85% 1RM (nine total trials). Force platform and kinematic data were collected to calculate pEKFM. To assess differences among loads and depths, a two-factor (load and depth) repeated-measures ANOVA with significance set at the P < 0.05 level was used. Squat 1RM significantly decreased 13.6% from the above parallel to parallel squat and another 3.6% from the parallel to the below parallel squat (P < 0.05). Net peak external knee flexion moments significantly increased as both squat depth and load were increased (P ≤ 0.02). Slopes of pEKFM were greater from unloaded to 50% 1RM than when progressing from 50% to 85% 1RM (P < 0.001). The results suggest that that typical decreases in squat loads used with increasing depths are not enough to offset increases in pEKFM. PMID:23085977

  15. Quantitative T2(*) assessment of knee joint cartilage after running a marathon.

    PubMed

    Hesper, Tobias; Miese, Falk R; Hosalkar, Harish S; Behringer, Michael; Zilkens, Christoph; Antoch, Gerald; Krauspe, Rüdiger; Bittersohl, Bernd

    2015-02-01

    To study the effect of repetitive joint loading on the T2(*) assessment of knee joint cartilage. T2(*) mapping was performed in 10 non-professional marathon runners (mean age: 28.7±3.97 years) with no morphologically evident cartilage damage within 48h prior to and following the marathon and after a period of approximately four weeks. Bulk and zonal T2(*) values at the medial and lateral tibiofemoral compartment and the patellofemoral compartment were assessed by means of region of interest analysis. Pre- and post-marathon values were compared. There was a small increase in the T2(*) after running the marathon (30.47±5.16ms versus 29.84±4.97ms, P<0.05) while the T2(*) values before the marathon and those after the period of convalescence were similar (29.84±4.97ms versus 29.81±5.17ms, P=0.855). Regional analyses revealed lower T2(*) values in the medial tibial plateau (P<0.001). It appears that repetitive joint loading has a transient influence on the T2(*) values. However, this effect is small and probably not clinically relevant. The low T2(*) values in the medial tibial plateau may be related to functional demand or early cartilage degeneration. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  16. MULTIPLE NONSPECIFIC SITES OF JOINT PAIN OUTSIDE THE KNEES DEVELOP IN PERSONS WITH KNEE PAIN

    PubMed Central

    Felson, David T.; Niu, Jingbo; Quinn, Emily K; Neogi, Tuhina; Lewis, Cara; Lewis, Cora E.; Law, Laura Frey; McCulloch, Chuck; Nevitt, Michael; LaValley, Michael

    2017-01-01

    Objective Many persons with knee pain have joint pain outside the knee but despite the impact and high frequency of this pain, its distribution and causes have not been studied. Those studying gait abnormalities have suggested that knee pain causes pain in adjacent joints but pain adaptation strategies are highly individualized. Methods We studied persons age 50-79 years with or at high risk of knee osteoarthritis drawn from two community-based cohorts, the Multicenter Osteoarthritis Study and the Osteoarthritis Initiative and followed for 5-7 years. We excluded those with knee pain at baseline and compared those who developed and did not develop knee pain at the first follow-up examination (the index visit). We examined pain on most days at joint regions outside the knee in examinations after the index visit. Logistic regression analyses examined the risk of joint specific pain adjusted for age, sex, BMI, depression with sensitivity analyses excluding those with widespread pain. Results In the combined cohorts, there were 693 persons with index visit knee pain vs. 2793 without it. 79.6% of those with bilateral and 63.8% of those with unilateral knee pain had pain during follow-up in a joint region outside the knee vs. 49.9% of those without knee pain. An increased risk of pain was present in most extremity joint sites without a predilection for specific sites. Results were unchanged when those with widespread pain were excluded. Conclusions Persons with chronic knee pain are at increased risk of pain in multiple joints in no specific pattern. PMID:27589036

  17. Effects of proprioceptive circuit exercise on knee joint pain and muscle function in patients with knee osteoarthritis.

    PubMed

    Ju, Sung-Bum; Park, Gi Duck; Kim, Sang-Soo

    2015-08-01

    [Purpose] This study applied proprioceptive circuit exercise to patients with degenerative knee osteoarthritis and examined its effects on knee joint muscle function and the level of pain. [Subjects] In this study, 14 patients with knee osteoarthritis in two groups, a proprioceptive circuit exercise group (n = 7) and control group (n = 7), were examined. [Methods] IsoMed 2000 (D&R Ferstl GmbH, Hemau, Germany) was used to assess knee joint muscle function, and a Visual Analog Scale was used to measure pain level. [Results] In the proprioceptive circuit exercise group, knee joint muscle function and pain levels improved significantly, whereas in the control group, no significant improvement was observed. [Conclusion] A proprioceptive circuit exercise may be an effective way to strengthen knee joint muscle function and reduce pain in patients with knee osteoarthritis.

  18. Kinematic analyses during stair descent in young women with patellofemoral pain.

    PubMed

    Grenholm, Anton; Stensdotter, Ann-Katrin; Häger-Ross, Charlotte

    2009-01-01

    Compensatory movement strategies may develop in response to pain to avoid stress on the affected area. Patellofemoral pain is characterised by intermittent periods of pain and the present study addresses whether long-term pain leads to compensatory movement strategies that remain even when the pain is absent. Lower extremity kinematics in three dimensions was studied in stair descent in 17 women with patellofemoral and in 17 matched controls. A two-dimensional geometric model was constructed to normalise kinematic data for subjects with varying anthropometrics when negotiating stairs of fixed proportions. There were minor differences in movement patterns between groups. Knee joint angular velocity in the stance leg at foot contact was lower and the movement trajectory tended to be jerkier in the patellofemoral group. The two-dimensional model showed greater plantar flexion in the swing leg in preparation for foot placement in the patellofemoral group. The results indicate that an altered stair descent strategy in the patellofemoral group may remain also in the absence of pain. The biomechanical interpretation presumes that the strategy is aimed to reduce knee joint loading by less knee joint moment and lower impact force.

  19. Translational and rotational knee joint stability in anterior and posterior cruciate-retaining knee arthroplasty.

    PubMed

    Lo, JiaHsuan; Müller, Otto; Dilger, Torsten; Wülker, Nikolaus; Wünschel, Markus

    2011-12-01

    This study investigated passive translational and rotational stability properties of the intact knee joint, after bicruciate-retaining bi-compartmental knee arthroplasty (BKA) and after posterior cruciate retaining total knee arthroplasty (TKA). Fourteen human cadaveric knee specimens were used in this study, and a robotic manipulator with six-axis force/torque sensor was used to test the joint laxity in anterior-posterior translation, valgus-varus, and internal-external rotation. The results show the knee joint stability after bicruciate-retaining BKA is similar to that of the native knee. On the other hand, the PCL-retaining TKA results in inferior joint stability in valgus, varus, external rotation, anterior and, surprisingly, posterior directions. Our findings suggest that, provided functional ligamentous structures, bicruciate-retaining BKA is a biomechanically attractive treatment for joint degenerative disease. Copyright © 2010 Elsevier B.V. All rights reserved.

  20. Meniscal tears, repairs and replacement: their relevance to osteoarthritis of the knee.

    PubMed

    McDermott, Ian

    2011-04-01

    The menisci of the knee are important load sharers and shock absorbers in the joint. Meniscal tears are common, and whenever possible meniscal tears should be surgically repaired. Meniscectomy leads to a significant increased risk of osteoarthritis, and various options now exist for replacing missing menisci, including the use of meniscal scaffolds or the replacement of the entire meniscus by meniscal allograft transplantation. The field of meniscal surgery continues to develop apace, and the future may lie in growing new menisci by tissue engineering techniques.

  1. The Effects of Knee Joint Effusion on Quadriceps Electromyography During Jogging

    PubMed Central

    Torry, Michael R.; Decker, Michael J.; Millett, Peter J.; Steadman, J. Richard; Sterett, William I.

    2005-01-01

    To investigate and describe the influence of intra-articular effusion on knee joint kinematics and electromyographic (EMG) profiles during jogging. Thirteen individuals underwent a 20 cc 0.9% saline insufflation of the knee joint capsule and completed 8 jogging trials. Stance phase, sagittal plane knee joint kinematics and thigh muscular EMG profiles were compared pre- and post-insufflation utilizing a paired t-test ( = 0.05). Mild knee effusion caused a reduction in vastus medialis (p = 0.005) and lateralis (p = 0.006) EMG activity. The rectus femoris, biceps femoris and medial hamstring muscles did not exhibit changes due to this protocol. There were no changes in the sagittal plane knee joint kinematic pattern. Twenty cc effusion can cause quadriceps inhibition in the vastus medialis and the vastus lateralis in otherwise healthy individuals during jogging. This study provides baseline data for the effects of mild knee joint effusion on thigh musculature during jogging. Key Points 20 cc of knee effusion can cause vastus medialis and lateralis inhibition as noted by decreases in EMG amplitude. This effusion does not appear to alter sagittal plane knee joint kinematics during jogging. This finding if different from previous work investigating knee joint kinematic changes during a less dynamic activity (gait) with 20 cc of effusion. PMID:24431955

  2. Relationship between lower limb dynamics and knee joint pain.

    PubMed

    Radin, E L; Yang, K H; Riegger, C; Kish, V L; O'Connor, J J

    1991-05-01

    To test the hypothesis that appropriate and timely neuromuscular control of limb motions plays an important role in the preservation of joint health, we kinematically and kinetically examined the behavior of the legs of young adult subjects at heel strike during natural walking. We compared a group of 18 volunteers, who, we presumed, were preosteoarthrotic because of mild, intermittent, activity-related knee joint pain, with 14 age-matched asymptomatic normal subjects. The two groups of subjects exhibited similar gait patterns with equivalent cadences, walking speeds, terminal stance phase knee flexion, maximum (peak) swing angular velocity, and overall shape of the vertical ground reaction. However, our instrumentation detected statistically significant differences between the two groups within a few milliseconds of heel strike. In the knee pain group, the heel hit the floor with a stronger impact in this brief interval. Just before heel strike, there was a faster downward velocity of the ankle with a larger angular velocity of the shank. The follow-through of the leg immediately after heel strike was more violent with larger peak axial and angular accelerations of the leg echoed by a more rapid rise of the ground reaction force. This sequence of events represents repetitive impulsive loading, which consistently provoked osteoarthrosis in animal experiments. We refer to this micro-incoordination of neuromuscular control not visible to the naked eye as "microklutziness."

  3. 21 CFR 888.3520 - Knee joint femorotibial metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/polymer non... § 888.3520 Knee joint femorotibial metal/polymer non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer non-constrained cemented prosthesis is a device intended to...

  4. 21 CFR 888.3520 - Knee joint femorotibial metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Knee joint femorotibial metal/polymer non... § 888.3520 Knee joint femorotibial metal/polymer non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer non-constrained cemented prosthesis is a device intended to...

  5. 21 CFR 888.3520 - Knee joint femorotibial metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Knee joint femorotibial metal/polymer non... § 888.3520 Knee joint femorotibial metal/polymer non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer non-constrained cemented prosthesis is a device intended to...

  6. 21 CFR 888.3520 - Knee joint femorotibial metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Knee joint femorotibial metal/polymer non... § 888.3520 Knee joint femorotibial metal/polymer non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer non-constrained cemented prosthesis is a device intended to...

  7. 21 CFR 888.3520 - Knee joint femorotibial metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Knee joint femorotibial metal/polymer non... § 888.3520 Knee joint femorotibial metal/polymer non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer non-constrained cemented prosthesis is a device intended to...

  8. Multiple Nonspecific Sites of Joint Pain Outside the Knees Develop in Persons With Knee Pain.

    PubMed

    Felson, David T; Niu, Jingbo; Quinn, Emily K; Neogi, Tuhina; Lewis, Cara L; Lewis, Cora E; Frey Law, Laura; McCulloch, Chuck; Nevitt, Michael; LaValley, Michael

    2017-02-01

    Many persons with knee pain have joint pain outside the knee, but despite the impact and high frequency of this pain, its distribution and causes have not been studied. We undertook this study to test the hypothesis of those studying gait abnormalities who have suggested that knee pain causes pain in adjacent joints but that pain adaptation strategies are highly individualized. We studied persons ages 50-79 years with or at high risk of knee osteoarthritis who were recruited from 2 community-based cohorts, the Multicenter Osteoarthritis Study and the Osteoarthritis Initiative, and we followed them up for 5-7 years. We excluded those with knee pain at baseline and compared those who had developed knee pain at the first follow-up examination (the index visit) with those who had not. We examined pain on most days at joint regions outside the knee in examinations after the index visit. Logistic regression analyses examined the risk of joint-specific pain adjusted for age, sex, body mass index, and symptoms of depression, and we performed sensitivity analyses excluding those with widespread pain. In the combined cohorts, 693 persons had knee pain at the index visit and 2,793 did not. A total of 79.6% of those with bilateral knee pain and 63.8% of those with unilateral knee pain had pain during follow-up in a joint region outside the knee, compared with 49.9% of those without knee pain. There was an increased risk of pain at most extremity joint sites, without a predilection for specific sites. Results were unchanged when those with widespread pain were excluded. Persons with chronic knee pain are at increased risk of pain in multiple joints in no specific pattern. © 2016, American College of Rheumatology.

  9. The structure and functioning of Dynastab DK - K fixator (knee joint) and its usefullness in clinical use.

    PubMed

    Deszczyński, J; Karpiński, J; Deszczyńska, H

    1999-12-30

    The autor describes following stages of research on external fixator Dynastab DK - K (knee joint) with in - built artificial joint enabling physiological range of movement of the knee and the use of the device in functional treatment of articular fractures of the knee. The final clinical prototype of the device was developed according to the results of the experiments with anatomical preparations of knee joints in which the trajectory of the physiological movement of the knee was stated. These observations were used to construct mechanical joint with the range of movement adequate to this of the healthy knee. The positive and negative aspects in DK - K fixator are also described. The fixator was appled in 6 difficult cases of articular fractures of knee with good results.

  10. Correlations between iron content in knee joint tissues and chosen indices of peripheral blood morphology.

    PubMed

    Brodziak-Dopierała, Barbara; Roczniak, Wojciech; Jakóbik-Kolon, Agata; Kluczka, Joanna; Koczy, Bogdan; Kwapuliński, Jerzy; Babuśka-Roczniak, Magdalena

    2017-10-01

    Iron as a cofactor of enzymes takes part in the synthesis of the bone matrix. Severe deficiency of iron reduces the strength and mineral density of bones, whereas its excess may increase oxidative stress. In this context, it is essential to determine the iron content in knee joint tissues. The study objective was to determine the level of iron in the tissues of the knee joint, i.e., in the femoral bone, tibia and meniscus. Material for analysis was obtained during endoprosthetic surgery of the knee joint. Within the knee joint, the tibia, femur and meniscus were analyzed. Samples were collected from 50 patients, including 36 women and 14 men. The determination of iron content was performed with the ICP-AES method, using Varian 710-ES. The lowest iron content was in the tibia (27.04 μg/g), then in the meniscus (38.68 μg/g) and the highest in the femur (41.93 μg/g). Statistically significant differences were noted in the content of iron in knee joint tissues. In patients who underwent endoprosthesoplasty of the knee joint, statistically significant differences were found in the levels of iron in various components of the knee joint. The highest iron content was found in the femoral bone of the knee joint and then in the meniscus, the lowest in the tibia. The differences in iron content in the knee joint between women and men were not statistically significant.

  11. Associations of knee muscle force, bone malalignment, and knee-joint laxity with osteoarthritis in elderly people.

    PubMed

    Nakagawa, Kazumasa; Maeda, Misako

    2017-03-01

    [Purpose] From the viewpoint of prevention of knee osteoarthritis, the aim of this study was to verify how muscle strength and joint laxity are related to knee osteoarthritis. [Subjects and Methods] The study subjects consisted of 90 community-dwelling elderly people aged more than 60 years (22 males, 68 females). Femorotibial angle alignment, knee joint laxity, knee extensors and flexor muscle strengths were measured in all subjects. In addition, the subjects were divided into four groups based on the presence of laxity and knee joint deformation, and the muscle strength values were compared. [Results] There was no significant difference in knee extensor muscle strength among the four groups. However, there was significant weakness of the knee flexor muscle in the group with deformation and laxity was compared with the group without deformation and laxity. [Conclusion] Decreased knee flexor muscle strengths may be involved in knee joint deformation. The importance of muscle strength balance was also considered.

  12. Correlation and sex differences between ankle and knee cartilage morphology determined by quantitative magnetic resonance imaging

    PubMed Central

    Eckstein, F; Siedek, V; Glaser, C; Al-Ali, D; Englmeier, K; Reiser, M; Graichen, H

    2004-01-01

    Objective: To study the correlation between ankle and knee cartilage morphology to test the hypothesis that knee joint cartilage loss in gonarthritis can be estimated retrospectively using quantitative MRI analysis of the knee and ankle and established regression equations; and to test the hypothesis that sex differences in joint surface area are larger in the knee than the ankle, which may explain the greater incidence of knee osteoarthritis in elderly women than in elderly men. Methods: Sagittal MR images (3D FLASH WE) of the knee and hind foot were acquired in 29 healthy subjects (14 women, 15 men; mean (SD) age, 25 (3) years), with no signs joint disease. Cartilage volume, thickness, and joint surface area were determined in the knee, ankle, and subtalar joint. Results: Knee cartilage volumes and joint surface areas showed only moderate correlations with those of the ankle and subtalar joint (r = 0.33 to 0.81). The correlations of cartilage thickness between the two joints were weaker still (r = –0.05 to 0.53). Sex differences in cartilage morphology at the knee and the ankle were similar, with surface areas being –17.5% to –23.5% lower in women than in men. Conclusions: Only moderate correlations in cartilage morphology of healthy subjects were found between knee and ankle. It is therefore impractical to estimate knee joint cartilage loss a posteriori in cross sectional studies by measuring the hind foot and then applying a scaling factor. Sex differences in cartilage morphology do not explain differences in osteoarthritis incidence between men and women in the knee and ankle. PMID:15479900

  13. Antagonist muscle co-contraction during a double-leg landing maneuver at two heights.

    PubMed

    Mokhtarzadeh, Hossein; Yeow, Chen Hua; Goh, James Cho Hong; Oetomo, Denny; Ewing, Katie; Lee, Peter Vee Sin

    2017-10-01

    Knee injuries are common during landing activities. Greater landing height increases peak ground reaction forces (GRFs) and loading at the knee joint. As major muscles to stabilize the knee joint, Quadriceps and Hamstring muscles provide internal forces to attenuate the excessive GRF. Despite the number of investigations on the importance of muscle function during landing, the role of landing height on these muscles forces using modeling during landing is not fully investigated. Participant-specific musculoskeletal models were developed using experimental motion analysis data consisting of anatomic joint motions and GRF from eight male participants performing double-leg drop landing from 30 and 60 cm. Muscle forces were calculated in OpenSim and their differences were analyzed at the instances of high risk during landing i.e. peak GRF for both heights. The maximum knee flexion angle and moments were found significantly higher from a double-leg landing at 60 cm compared to 30 cm. The results showed elevated GRF, and mean muscle forces during landing. At peak GRF, only quadriceps showed significantly greater forces at 60 cm. Hamstring muscle forces did not significantly change at 60 cm compared to 30 cm. Quadriceps and hamstring muscle forces changed at different heights. Since hamstring forces were similar in both landing heights, this could lead to an imbalance between the antagonist muscles, potentially placing the knee at risk of injury if combined with small flexion angles that was not observed at peak GRF in our study. Thus, enhanced neuromuscular training programs strengthening the hamstrings may be required to address this imbalance. These findings may contribute to enhance neuromuscular training programs to prevent knee injuries during landing.

  14. Decline eccentric squats increases patellar tendon loading compared to standard eccentric squats.

    PubMed

    Kongsgaard, M; Aagaard, P; Roikjaer, S; Olsen, D; Jensen, M; Langberg, H; Magnusson, S P

    2006-08-01

    Recent studies have shown excellent clinical results using eccentric squat training on a 25 degrees decline board to treat patellar tendinopathy. It remains unknown why therapeutic management of patellar tendinopathy using decline eccentric squats offer superior clinical efficacy compared to standard horizontal eccentric squats. This study aimed to compare electromyography activity, patellar tendon strain and joint angle kinematics during standard and decline eccentric squats. Thirteen subjects performed unilateral eccentric squats on flat-and a 25 degrees decline surface. During the squats, electromyography activity was obtained in eight representative muscles. Also, ankle, knee and hip joint goniometry was obtained. Additionally, patellar tendon strain was measured in vivo using ultrasonography as subjects maintained a unilateral isometric 90 degrees knee angle squat position on either flat or 25 degrees decline surface. Patellar tendon strain was significantly greater (P<0.05) during the squat position on the decline surface compared to the standard surface. The stop angles of the ankle and hip joints were significantly smaller during the decline compared to the standard squats (P<0.001, P<0.05). Normalized mean electromyography amplitudes of the knee extensor muscles were significantly greater during the decline compared to the standard squats (P<0.05). Hamstring and calf muscle mean electromyography did not differ, respectively, between standard and decline squats. The use of a 25 degrees decline board increases the load and the strain of the patellar tendon during unilateral eccentric squats. This finding likely explains previous reports of superior clinical efficacy of decline eccentric squats in the rehabilitative management of patellar tendinopathy.

  15. 21 CFR 888.3570 - Knee joint femoral (hemi-knee) metallic uncemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Knee joint femoral (hemi-knee) metallic uncemented prosthesis. 888.3570 Section 888.3570 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3570 Knee joint...

  16. 21 CFR 888.3570 - Knee joint femoral (hemi-knee) metallic uncemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Knee joint femoral (hemi-knee) metallic uncemented prosthesis. 888.3570 Section 888.3570 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3570 Knee joint...

  17. 21 CFR 888.3570 - Knee joint femoral (hemi-knee) metallic uncemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Knee joint femoral (hemi-knee) metallic uncemented prosthesis. 888.3570 Section 888.3570 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3570 Knee joint...

  18. 21 CFR 888.3570 - Knee joint femoral (hemi-knee) metallic uncemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Knee joint femoral (hemi-knee) metallic uncemented prosthesis. 888.3570 Section 888.3570 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3570 Knee joint...

  19. Finite element analysis of the valgus knee joint of an obese child.

    PubMed

    Sun, Jun; Yan, Songhua; Jiang, Yan; Wong, Duo Wai-Chi; Zhang, Ming; Zeng, Jizhou; Zhang, Kuan

    2016-12-28

    Knee valgus and varus morbidity is at the second top place in children lower limb deformity diseases. It may cause abnormal stress distribution. The magnitude and location of contact forces on tibia plateau during gait cycle have been indicated as markers for risk of osteoarthritis. So far, few studies reported the contact stress and force distribution on tibial plateau of valgus knee of children. To estimate the contact stresses and forces on tibial plateau of an 8-year old obese boy with valgus knee and a 7-year old healthy boy, three-dimensional (3D) finite element (FE) models of their left knee joints were developed. The valgus knee model has 36,897 nodes and 1,65,106 elements, and the normal knee model has 78,278 nodes and 1,18,756 elements. Paired t test was used for the comparison between the results from the 3D FE analysis method and the results from traditional kinematic measurement methods. The p value of paired t test is 0.12. Maximum stresses shifted to lateral plateau in knee valgus children while maximum stresses were on medial plateau in normal knee child at the first peak of vertical GRF of stance phase. The locations of contact centers on medial plateau changed 3.38 mm more than that on lateral plateau, while the locations of contact centers on medial plateau changed 1.22 mm less than that on lateral plateau for healthy child from the first peak to second peak of vertical GRF of stance phase. The paired t test result shows that there is no significant difference between the two methods. The results of FE analysis method suggest that knee valgus malalignment could be the reason for abnormal knee load that may cause knee problems in obese children with valgus knee in the long-term. This study may help to understand biomechanical mechanism of valgus knees of obese children.

  20. Soft tissue artifact compensation in knee kinematics by multi-body optimization: Performance of subject-specific knee joint models.

    PubMed

    Clément, Julien; Dumas, Raphaël; Hagemeister, Nicola; de Guise, Jaques A

    2015-11-05

    Soft tissue artifact (STA) distort marker-based knee kinematics measures and make them difficult to use in clinical practice. None of the current methods designed to compensate for STA is suitable, but multi-body optimization (MBO) has demonstrated encouraging results and can be improved. The goal of this study was to develop and validate the performance of knee joint models, with anatomical and subject-specific kinematic constraints, used in MBO to reduce STA errors. Twenty subjects were recruited: 10 healthy and 10 osteoarthritis (OA) subjects. Subject-specific knee joint models were evaluated by comparing dynamic knee kinematics recorded by a motion capture system (KneeKG™) and optimized with MBO to quasi-static knee kinematics measured by a low-dose, upright, biplanar radiographic imaging system (EOS(®)). Errors due to STA ranged from 1.6° to 22.4° for knee rotations and from 0.8 mm to 14.9 mm for knee displacements in healthy and OA subjects. Subject-specific knee joint models were most effective in compensating for STA in terms of abduction-adduction, inter-external rotation and antero-posterior displacement. Root mean square errors with subject-specific knee joint models ranged from 2.2±1.2° to 6.0±3.9° for knee rotations and from 2.4±1.1 mm to 4.3±2.4 mm for knee displacements in healthy and OA subjects, respectively. Our study shows that MBO can be improved with subject-specific knee joint models, and that the quality of the motion capture calibration is critical. Future investigations should focus on more refined knee joint models to reproduce specific OA knee geometry and physiology. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Influence of restricted vision and knee joint range of motion on gait properties during level walking and stair ascent and descent.

    PubMed

    Demura, Tomohiro; Demura, Shin-ich

    2011-01-01

    Because elderly individuals experience marked declines in various physical functions (e.g., vision, joint function) simultaneously, it is difficult to clarify the individual effects of these functional declines on walking. However, by imposing vision and joint function restrictions on young men, the effects of these functional declines on walking can be clarified. The authors aimed to determine the effect of restricted vision and range of motion (ROM) of the knee joint on gait properties while walking and ascending or descending stairs. Fifteen healthy young adults performed level walking and stair ascent and descent during control, vision restriction, and knee joint ROM restriction conditions. During level walking, walking speed and step width decreased, and double support time increased significantly with vision and knee joint ROM restrictions. Stance time, step width, and walking angle increased only with knee joint ROM restriction. Stance time, swing time, and double support time were significantly longer in level walking, stair descent, and stair ascent, in that order. The effects of vision and knee joint ROM restrictions were significantly larger than the control conditions. In conclusion, vision and knee joint ROM restrictions affect gait during level walking and stair ascent and descent. This effect is marked in stair ascent with knee joint ROM restriction.

  2. The effects of transcutaneous electrical nerve stimulation on joint position sense in patients with knee joint osteoarthritis.

    PubMed

    Shirazi, Zahra Rojhani; Shafaee, Razieh; Abbasi, Leila

    2014-10-01

    To study the effects of transcutaneous electrical nerve stimulation (TENS) on joint position sense (JPS) in knee osteoarthritis (OA) subjects. Thirty subjects with knee OA (40-60 years old) using non-random sampling participated in this study. In order to evaluate the absolute error of repositioning of the knee joint, Qualysis Track Manager system was used and sensory electrical stimulation was applied through the TENS device. The mean errors in repositioning of the joint, in two position of the knee joint with 20 and 60 degree angle, after applying the TENS was significantly decreased (p < 0.05). Application of TENS in subjects with knee OA could improve JPS in these subjects.

  3. Ballistic movements of jumping legs implemented as variable components of cricket behaviour.

    PubMed

    Hustert, R; Baldus, M

    2010-12-01

    Ballistic accelerations of a limb or the whole body require special joint mechanisms in many animals. Specialized joints can be moved by stereotypic or variable motor control during motor patterns with and without ballistic components. As a model of variable motor control, the specialized femur-tibia (knee) joints of cricket (Acheta domesticus) hindlegs were studied during ballistic kicking, jumping and swimming and in non-ballistic walking. In this joint the tendons of the antagonistic flexor and the extensor muscles attach at different distances from the pivot and the opposed lever arms form an angle of 120 deg. A 10:1 ratio of their effective lever arms at full knee flexion helps to prepare for most ballistic extensions: the tension of the extensor can reach its peak while it is restrained by flexor co-contraction. In kicks, preparatory flexion is rapid and the co-contraction terminates just before knee extensions. Therefore, mainly the stored tension of the extensor muscle accelerates the small mass of the tibia. Jumps are prepared with slower extensor-flexor co-contractions that flex both knees simultaneously and then halt to rotate both legs outward to a near horizontal level. From there, catapult extension of both knees accelerates the body, supported by continued high frequency motor activity to their tibia extensor muscles during the ongoing push-off from the substrate. Premature extension of one knee instantly takes load from the lagging leg that extends and catches up, which finally results in a straight jump. In swimming, synchronous ballistic power strokes of both hindlegs drive the tibiae on a ventral-to-posterior trajectory through the water, well coordinated with the swimming patterns of all legs. In walking, running and climbing the steps of the hindlegs range between 45 deg flexion and 125 deg extension and use non-ballistic, alternating activity of knee flexor and extensor muscles. Steep climbing requires longer bursts from the extensor tibiae muscles when they support the extended hindlegs against gravity forces when the body hangs over. All ballistic movements of cricket knees are elicited by a basic but variable motor pattern: knee flexions by co-contraction of the antagonists prepare catapult extensions with speeds and forces as required in the different behaviours.

  4. No associations between self-reported knee joint instability and radiographic features in knee osteoarthritis patients prior to Total Knee Arthroplasty: A cross-sectional analysis of the Longitudinal Leiden Orthopaedics Outcomes of Osteo-Arthritis study (LOAS) data.

    PubMed

    Leichtenberg, Claudia S; Meesters, Jorit J L; Kroon, Herman M; Verdegaal, Suzan H M; Tilbury, Claire; Dekker, Joost; Nelissen, Rob G H H; Vliet Vlieland, Thea P M; van der Esch, Martin

    2017-08-01

    To describe the prevalence of self-reported knee joint instability in patients with pre-surgery knee osteoarthritis (OA) and to explore the associations between self-reported knee joint instability and radiological features. A cross-sectional study including patients scheduled for primary Total Knee Arthroplasty (TKA). Self-reported knee instability was examined by questionnaire. Radiological features consisted of osteophyte formation and joint space narrowing (JSN), both scored on a 0 to three scale. Scores >1 are defined as substantial JSN or osteophyte formation. Regression analyses were provided to identify associations of radiological features with self-reported knee joint instability. Two hundred and sixty-five patients (mean age 69years and 170 females) were included. Knee instability was reported by 192 patients (72%). Substantial osteophyte formation was present in 78 patients (41%) reporting and 33 patients (46%) not reporting knee joint instability. Substantial JSN was present in 137 (71%) and 53 patients (73%), respectively. Self-reported knee instability was not associated with JSN (relative to score 0, odds ratios (95% CI) of score 1, 2 and 3 were 0.87 (0.30-2.54), 0.98 (0.38-2.52), 0.68 (0.25-1.86), respectively) or osteophyte formation (relative to score 0, odds ratios (95% CI) of score 1, 2 and 3 were 0.77 (0.36-1.64), 0.69 (0.23-1.45), 0.89 (0.16-4.93), respectively). Stratified analysis for pain, age and BMI showed no associations between self-reported knee joint instability and radiological features. Self-reported knee joint instability is not associated with JSN or osteophyte formation. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Strain measurements of the tibial insert of a knee prosthesis using a knee motion simulator.

    PubMed

    Sera, Toshihiro; Iwai, Yuya; Yamazaki, Takaharu; Tomita, Tetsuya; Yoshikawa, Hideki; Naito, Hisahi; Matsumoto, Takeshi; Tanaka, Masao

    2017-12-01

    The longevity of a knee prosthesis is influenced by the wear of the tibial insert due to its posture and movement. In this study, we assumed that the strain on the tibial insert is one of the main reasons for its wear and investigated the influence of the knee varus-valgus angles on the mechanical stress of the tibial insert. Knee prosthesis motion was simulated using a knee motion simulator based on a parallel-link six degrees-of-freedom actuator and the principal strain and pressure distribution of the tibial insert were measured. In particular, the early stance phase obtained from in vivo X-ray images was examined because the knee is applied to the largest load during extension/flexion movement. The knee varus-valgus angles were 0° (neutral alignment), 3°, and 5° malalignment. Under a neutral orientation, the pressure was higher at the middle and posterior condyles. The first and second principal strains were larger at the high and low pressure areas, respectively. Even for a 3° malalignment, the load was concentrated at one condyle and the positive first principal strain increased dramatically at the high pressure area. The negative second principal strain was large at the low pressure area on the other condyle. The maximum equivalent strain was 1.3-2.1 times larger at the high pressure area. For a 5° malalignment, the maximum equivalent strain increased slightly. These strain and pressure measurements can provide the mechanical stress of the tibial insert in detail for determining the longevity of an artificial knee joint.

  6. Arch structure is associated with unique joint work, relative joint contributions and stiffness during landing.

    PubMed

    Powell, Douglas W; Queen, Robin M; Williams, D S Blaise

    2016-10-01

    To examine lower extremity joint contributions to a landing task in high-(HA) and low-arched (LA) female athletes by quantifying vertical stiffness, joint work and relative joint contributions to landing. Twenty healthy female recreational athletes (10 HA and 10 LA) performed five barefoot drop landings from a height of 30cm. Three-dimensional kinematics (240Hz) and ground reaction forces (960Hz) were recorded simultaneously. Vertical stiffness, joint work values and relative joint work values were calculated using Visual 3D and MatLab. HA athletes had significantly greater vertical stiffness compared to LA athletes (p=0.013). Though no differences in ankle joint work were observed (p=0.252), HA athletes had smaller magnitudes of knee (p=0.046), hip (p=0.019) and total lower extremity joint work values (p=0.016) compared to LA athletes. HA athletes had greater relative contributions of the ankle (p=0.032) and smaller relative contributions of the hip (p=0.049) compared to LA athletes. No differences in relative contributions of the knee were observed (p=0.255). These findings demonstrate that aberrant foot structure is associated with unique contributions of lower extremity joints to load attenuation during landing. These data may provide insight into the unique injury mechanisms associated with arch height in female athletes. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Influence of bi- and tri-compartmental knee arthroplasty on the kinematics of the knee joint.

    PubMed

    Wünschel, Markus; Lo, Jiahsuan; Dilger, Torsten; Wülker, Nikolaus; Müller, Otto

    2011-01-27

    The cruciate ligaments are important stabilizers of the knee joint and determine joint kinematics in the natural knee and after cruciate retaining arthroplasty.No in vitro data is available to biomechanically evaluate the ability of the anterior cruciate ligament (ACL) to maintain knee joint kinematics after bicruciate-retaining bi-compartmental knee arthroplasty (BKA).Therefore, the objective of the current study was to investigate the kinematics of the natural knee joint, before and after installing bicruciate-retaining BKA and posterior cruciate retaining total knee arthroplasty. Specifically, we incorporated a dynamic knee simulator to simulate weight-bearing flexions on cadaveric knee specimen before and after surgical manipulations. In this cadaveric study we investigated rotational and translational tibiofemoral kinematics during simulated weight-bearing flexions of the intact knee, after bi-compartmental knee arthroplasty (BKA+), after resecting the ACL in BKA (BKA-), and after posterior cruciate retaining total knee arthroplasty (TKA). Rotation of BKA+ is closest to the intact knee joint, whereas TKA shows significant differences from 30 to 90 degree of flexion. Within the tested flexion range (15 to 90 degree of flexion), there was no significant difference in the anterior-posterior translation among intact, BKA+, and TKA knees. Resecting the ACL in BKA leads to a significant anterior tibial translation. BKA with intact cruciate ligaments resembles rotation and translation of the natural knee during a simulated weight-bearing flexion. It is a suitable treatment option for medial and patellofemoral osteoarthritis with advantages in rotational characteristics compared to TKA.

  8. Joint Mobilization Enhances Mechanisms of Conditioned Pain Modulation in Individuals With Osteoarthritis of the Knee.

    PubMed

    Courtney, Carol A; Steffen, Alana D; Fernández-de-Las-Peñas, César; Kim, John; Chmell, Samuel J

    2016-03-01

    An experimental laboratory study with a repeated-measures crossover design. Treatment effects of joint mobilization may occur in part by decreasing excitability of central nociceptive pathways. Impaired conditioned pain modulation (CPM) has been found experimentally in persons with knee and hip osteoarthritis, indicating impaired inhibition of central nociceptive pathways. We hypothesized increased effectiveness of CPM following application of joint mobilization, determined via measures of deep tissue hyperalgesia. To examine the effect of joint mobilization on impaired CPM. An examination of 40 individuals with moderate/severe knee osteoarthritis identified 29 (73%) with impaired CPM. The subjects were randomized to receive 6 minutes of knee joint mobilization (intervention) or manual cutaneous input only, 1 week apart. Deep tissue hyperalgesia was examined via pressure pain thresholds bilaterally at the knee medial joint line and the hand at baseline, postintervention, and post-CPM testing. Further, vibration perception threshold was measured at the medial knee epicondyle at baseline and post-CPM testing. Joint mobilization, but not cutaneous input intervention, resulted in a global increase in pressure pain threshold, indicated by diminished hyperalgesic responses to pressure stimulus. Further, CPM was significantly enhanced following joint mobilization. Diminished baseline vibration perception threshold acuity was enhanced following joint mobilization at the knee that received intervention, but not at the contralateral knee. Resting pain was also significantly lower following the joint intervention. Conditioned pain modulation was enhanced following joint mobilization, demonstrated by a global decrease in deep tissue pressure sensitivity. Joint mobilization may act via enhancement of descending pain mechanisms in patients with painful knee osteoarthritis.

  9. Mechanical correction of dynamometer moment for the effects of segment motion during isometric knee-extension tests

    PubMed Central

    Baltzopoulos, Vasilios; Richards, Paula J.; Maganaris, Constantinos N.

    2011-01-01

    The purpose of this study was to determine the effect of dynamometer and joint axis misalignment on measured isometric knee-extension moments using inverse dynamics based on the actual joint kinematic information derived from the real-time X-ray video and to compare the errors when the moments were calculated using measurements from external anatomical surface markers or obtained from the isokinetic dynamometer. Six healthy males participated in this study. They performed isometric contractions at 90° and 20° of knee flexion, gradually increasing to maximum effort. For the calculation of the actual knee-joint moment and the joint moment relative to the knee-joint center, determined using the external marker, two free body diagrams were used of the Cybex arm and the lower leg segment system. In the first free body diagram, the mean center of the circular profiles of the femoral epicondyles was used as the knee-joint center, whereas in the second diagram, the joint center was assumed to coincide with the external marker. Then, the calculated knee-joint moments were compared with those measured by the dynamometer. The results indicate that 1) the actual knee-joint moment was different from the dynamometer recorded moment (difference ranged between 1.9% and 4.3%) and the moment calculated using the skin marker (difference ranged between 2.5% and 3%), and 2) during isometric knee extension, the internal knee angle changed significantly from rest to the maximum contraction state by about 19°. Therefore, these differences cannot be neglected if the moment–knee-joint angle relationship or the muscle mechanical properties, such as length-tension relationship, need to be determined. PMID:21474701

  10. How tibiofemoral alignment and contact locations affect predictions of medial and lateral tibiofemoral contact forces.

    PubMed

    Lerner, Zachary F; DeMers, Matthew S; Delp, Scott L; Browning, Raymond C

    2015-02-26

    Understanding degeneration of biological and prosthetic knee joints requires knowledge of the in-vivo loading environment during activities of daily living. Musculoskeletal models can estimate medial/lateral tibiofemoral compartment contact forces, yet anthropometric differences between individuals make accurate predictions challenging. We developed a full-body OpenSim musculoskeletal model with a knee joint that incorporates subject-specific tibiofemoral alignment (i.e. knee varus-valgus) and geometry (i.e. contact locations). We tested the accuracy of our model and determined the importance of these subject-specific parameters by comparing estimated to measured medial and lateral contact forces during walking in an individual with an instrumented knee replacement and post-operative genu valgum (6°). The errors in the predictions of the first peak medial and lateral contact force were 12.4% and 11.9%, respectively, for a model with subject-specific tibiofemoral alignment and contact locations determined through radiographic analysis, vs. 63.1% and 42.0%, respectively, for a model with generic parameters. We found that each degree of tibiofemoral alignment deviation altered the first peak medial compartment contact force by 51N (r(2)=0.99), while each millimeter of medial-lateral translation of the compartment contact point locations altered the first peak medial compartment contact force by 41N (r(2)=0.99). The model, available at www.simtk.org/home/med-lat-knee/, enables the specification of subject-specific joint alignment and compartment contact locations to more accurately estimate medial and lateral tibiofemoral contact forces in individuals with non-neutral alignment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. How Tibiofemoral Alignment and Contact Locations Affect Predictions of Medial and Lateral Tibiofemoral Contact Forces

    PubMed Central

    Lerner, Zachary F.; DeMers, Matthew S.; Delp, Scott L.; Browning, Raymond C.

    2015-01-01

    Understanding degeneration of biological and prosthetic knee joints requires knowledge of the in-vivo loading environment during activities of daily living. Musculoskeletal models can estimate medial/lateral tibiofemoral compartment contact forces, yet anthropometric differences between individuals make accurate predictions challenging. We developed a full-body OpenSim musculoskeletal model with a knee joint that incorporates subject-specific tibiofemoral alignment (i.e. knee varus-valgus) and geometry (i.e. contact locations). We tested the accuracy of our model and determined the importance of these subject-specific parameters by comparing estimated to measured medial and lateral contact forces during walking in an individual with an instrumented knee replacement and post-operative genu valgum (6°). The errors in the predictions of the first peak medial and lateral contact force were 12.4% and 11.9%, respectively, for a model with subject-specific tibiofemoral alignment and contact locations determined via radiographic analysis, vs. 63.1% and 42.0%, respectively, for a model with generic parameters. We found that each degree of tibiofemoral alignment deviation altered the first peak medial compartment contact force by 51N (r2=0.99), while each millimeter of medial-lateral translation of the compartment contact point locations altered the first peak medial compartment contact force by 41N (r2=0.99). The model, available at www.simtk.org/home/med-lat-knee/, enables the specification of subject-specific joint alignment and compartment contact locations to more accurately estimate medial and lateral tibiofemoral contact forces in individuals with non-neutral alignment. PMID:25595425

  12. Joint laxity and the relationship between muscle strength and functional ability in patients with osteoarthritis of the knee.

    PubMed

    van der Esch, M; Steultjens, M; Knol, D L; Dinant, H; Dekker, J

    2006-12-15

    To establish the impact of knee joint laxity on the relationship between muscle strength and functional ability in osteoarthritis (OA) of the knee. A cross-sectional study of 86 patients with OA of the knee was conducted. Tests were performed to determine varus-valgus laxity, muscle strength, and functional ability. Laxity was assessed using a device that measures the angular deviation of the knee in the frontal plane. Muscle strength was measured using a computer-driven isokinetic dynamometer. Functional ability was assessed by observation (100-meter walking test) and self report (Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC]). Regression analyses were performed to assess the impact of joint laxity on the relationship between muscle strength and functional ability. In regression analyses, the interaction between muscle strength and joint laxity contributed to the variance in both walking time (P = 0.002) and WOMAC score (P = 0.080). The slope of the regression lines indicated that the relationship between muscle strength and functional ability (walking time, WOMAC) was stronger in patients with high knee joint laxity. Patients with knee OA and high knee joint laxity show a stronger relationship between muscle strength and functional ability than patients with OA and low knee joint laxity. Patients with OA, high knee joint laxity, and low muscle strength are most at risk of being disabled.

  13. Improvement of the knee center of rotation during walking after opening wedge high tibial osteotomy.

    PubMed

    Kim, Kyungsoo; Feng, Jun; Nha, Kyung Wook; Park, Won Man; Kim, Yoon Hyuk

    2015-06-01

    Accurate measurement of the center of rotation of the knee joint is indispensable for prediction of joint kinematics and kinetics in musculoskeletal models. However, no study has yet identified the knee center of rotations during several daily activities before and after high tibial osteotomy surgery, which is one surgical option for treating knee osteoarthritis. In this study, an estimation method for determining the knee joint center of rotation was developed by applying the optimal common shape technique and symmetrical axis of rotation approach techniques to motion-capture data and validated for typical activities (walking, squatting, climbing up stairs, walking down stairs) of 10 normal subjects. The locations of knee joint center of rotations for injured and contralateral knees of eight subjects with osteoarthritis, both before and after high tibial osteotomy surgery, were then calculated during walking. It was shown that high tibial osteotomy surgery improved the knee joint center of rotation since the center of rotations for the injured knee after high tibial osteotomy surgery were significantly closer to those of the normal healthy population. The difference between the injured and contralateral knees was also generally reduced after surgery, demonstrating increased symmetry. These results indicate that symmetry in both knees can be recovered in many cases after high tibial osteotomy surgery. Moreover, the recovery of center of rotation in the injured knee was prior to that of symmetry. This study has the potential to provide fundamental information that can be applied to understand abnormal kinematics in patients, diagnose knee joint disease, and design a novel implants for knee joint surgeries. © IMechE 2015.

  14. Cryotherapy impairs knee joint position sense.

    PubMed

    Oliveira, R; Ribeiro, F; Oliveira, J

    2010-03-01

    The effects of cryotherapy on joint position sense are not clearly established; however it is paramount to understand its impact on peripheral feedback to ascertain the safety of using ice therapy before resuming exercise on sports or rehabilitation settings. Thus, the aim of the present study was to determine the effects of cryotherapy, when applied over the quadriceps and over the knee joint, on knee position sense. This within-subjects repeated-measures study encompassed fifteen subjects. Knee position sense was measured by open kinetic chain technique and active positioning at baseline and after cryotherapy application. Knee angles were determined by computer analysis of the videotape images. Twenty-minute ice bag application was applied randomly, in two sessions 48 h apart, over the quadriceps and the knee joint. The main effect for cryotherapy application was significant (F (1.14)=7.7, p=0.015) indicating an increase in both absolute and relative angular errors after the application. There was no significant main effect for the location of cryotherapy application, indicating no differences between the application over the quadriceps and the knee joint. In conclusion, cryotherapy impairs knee joint position sense in normal knees. This deleterious effect is similar when cryotherapy is applied over the quadriceps or the knee joint. Georg Thieme Verlag KG Stuttgart.New York.

  15. Functional added value of microprocessor-controlled knee joints in daily life performance of Medicare Functional Classification Level-2 amputees.

    PubMed

    Theeven, Patrick; Hemmen, Bea; Rings, Frans; Meys, Guido; Brink, Peter; Smeets, Rob; Seelen, Henk

    2011-10-01

    To assess the effects of using a microprocessor-controlled prosthetic knee joint on the functional performance of activities of daily living in persons with an above-knee leg amputation. To assess the effects of using a microprocessor-controlled prosthetic knee joint on the functional performance of activities of daily living in persons with an above-knee leg amputation. Randomised cross-over trial. Forty-one persons with unilateral above-knee or knee disarticulation limb loss, classified as Medicare Functional Classification Level-2 (MFCL-2). Participants were measured in 3 conditions, i.e. using a mechanically controlled knee joint and two types of microprocessor-controlled prosthetic knee joints. Functional performance level was assessed using a test in which participants performed 17 simulated activities of daily living (Assessment of Daily Activity Performance in Transfemoral amputees test). Performance time was measured and self-perceived level of difficulty was scored on a visual analogue scale for each activity. High levels of within-group variability in functional performance obscured detection of any effects of using a microprocessor-controlled prosthetic knee joint. Data analysis after stratification of the participants into 3 subgroups, i.e. participants with a "low", "intermediate" and "high" functional mobility level, showed that the two higher functional subgroups performed significantly faster using microprocessor-controlled prosthetic knee joints. MFCL-2 amputees constitute a heterogeneous patient group with large variation in functional performance levels. A substantial part of this group seems to benefit from using a microprocessor-controlled prosthetic knee joint when performing activities of daily living.

  16. Hip or knee replacement - after - what to ask your doctor

    MedlinePlus

    ... chap 7. Read More Hip joint replacement Hip pain Knee joint replacement Knee pain Osteoarthritis Patient Instructions Getting your home ready - knee or hip surgery Hip or knee replacement - before - ...

  17. Hip or knee replacement - before - what to ask your doctor

    MedlinePlus

    ... chap 7. Read More Hip joint replacement Hip pain Knee joint replacement Knee pain Osteoarthritis Patient Instructions Getting your home ready - knee or hip surgery Hip or knee replacement - after - ...

  18. Prevalence of joint-related pain in the extremities and spine in five groups of top athletes.

    PubMed

    Jonasson, Pall; Halldin, Klas; Karlsson, Jon; Thoreson, Olof; Hvannberg, Jonas; Swärd, Leif; Baranto, Adad

    2011-09-01

    Joint-related pain conditions from the spine and extremities are common among top athletes. The frequency of back pain has, however, been studied in more detail, and the frequency of low-back pain in top athletes in different high-load sports has been reported to be as high as 85%. Sport-related pain from different joints in the extremities is, however, infrequently reported on in the literature. Seventy-five male athletes, i.e. divers, weight-lifters, wrestlers, orienteers and ice-hockey players and 12 non-athletes (control group) were included in the study. A specific self-assessed pain-oriented questionnaire related to the cervical, thoracic and lumbar spine, as well as the various joints, i.e. shoulders, elbows, wrists, hips, knees and ankles, was filled out by the athletes and the non-athletes. The overall frequency of pain reported by the athletes during the last week/last year was as follows; cervical spine 35/55%; thoracic spine 22/33%; lumbar spine 50/68%; shoulder 10/21%; elbow 7/7%; wrist 7/8%; hip 15/23%; knee 22/44%; and ankle 11/25%. The corresponding values for non-athletes were cervical spine 9/36%; thoracic spine 17/33%; lumbar spine 36/50%; shoulder 0/9%; elbow 9/0%; wrist 0/0%; hip 9/16%; knee 10/9%; and ankle 0/0%. A higher percentage of athletes reported pain in almost all joint regions, but there were no statistically significant differences (n.s.), with the exception of the knees (P = 0.05). Over the last year, athletes reporting the highest pain frequency in the lumbar spine were ice-hockey players and, in the cervical spine, wrestlers and ice-hockey players. The highest levels of knee pain were found among wrestlers and ice-hockey players, whereas the highest levels for wrist pain were found among divers, hip pain among weight-lifters, orienteers and divers and ankle pain among orienteers. For the thoracic spine, shoulder and elbow regions, only minor differences were found. There was no statistically significant difference in prevalence of pain in the neck, spine and joints between top athletes in different sports or between athletes and non-athletes. However, pain in one spinal region was correlated to reported pain in other regions of the spine. Moreover, pain in the spine was also correlated to pain in the shoulders, hips and knees.

  19. Knee joint changes in patients with neglected developmental hip dysplasia: a prospective case-control study.

    PubMed

    Li, Qiwei; Kadhim, Muayad; Zhang, Lijun; Cheng, Xiangjun; Zhao, Qun; Li, Lianyong

    2014-12-01

    Few reports are available describing knee changes in neglected developmental dysplasia of the hip (DDH). The purpose of this study was to assess the radiographic morphology of knee joints in adults with neglected DDH. Thirty-seven patients (35 females and two males) with neglected DDH were prospectively recruited with an average age of 32.6 years. Twenty-three patients had unilateral and 14 patients had bilateral neglected DDH. Thirty-seven healthy individuals were recruited to form a matched control group. Three groups of knee joints were examined: affected knees (on the same side of the neglected DDH), unaffected knees (contralateral to the neglected DDH in patients with unilateral involvement), and control knees. A series of radiographic parameters of the knee joint were measured in the coronal and sagittal plane, and they were compared between patients and normal controls. In the coronal plane, the affected knees had increased valgus angulation related to increased height of the medial femoral condyle, decreased height of the lateral femoral condyle and decreased lateral distal femoral angle compared to control knees. In the sagittal plane, both distal femoral and proximal tibial joints of the affected knees developed a decrease in posterior angles. Additionally, the unaffected knees also developed radiographic changes compared to control knees. Patients with neglected DDH may develop changes in both knee joints. These changes should be considered during surgery to the hip, femur and knee to prevent potential complications. Level 2. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Modelling of the Human Knee Joint Supported by Active Orthosis

    NASA Astrophysics Data System (ADS)

    Musalimov, V.; Monahov, Y.; Tamre, M.; Rõbak, D.; Sivitski, A.; Aryassov, G.; Penkov, I.

    2018-02-01

    The article discusses motion of a healthy knee joint in the sagittal plane and motion of an injured knee joint supported by an active orthosis. A kinematic scheme of a mechanism for the simulation of a knee joint motion is developed and motion of healthy and injured knee joints are modelled in Matlab. Angles between links, which simulate the femur and tibia are controlled by Simulink block of Model predictive control (MPC). The results of simulation have been compared with several samples of real motion of the human knee joint obtained from motion capture systems. On the basis of these analyses and also of the analysis of the forces in human lower limbs created at motion, an active smart orthosis is developed. The orthosis design was optimized to achieve an energy saving system with sufficient anatomy, necessary reliability, easy exploitation and low cost. With the orthosis it is possible to unload the knee joint, and also partially or fully compensate muscle forces required for the bending of the lower limb.

Top