Sample records for knife mill screen

  1. Direct measures of mechanical energy for knife mill size reduction of switchgrass, wheat straw, and corn stover.

    PubMed

    Bitra, Venkata S P; Womac, Alvin R; Igathinathane, C; Miu, Petre I; Yang, Yuechuan T; Smith, David R; Chevanan, Nehru; Sokhansanj, Shahab

    2009-12-01

    Lengthy straw/stalk of biomass may not be directly fed into grinders such as hammer mills and disc refiners. Hence, biomass needs to be preprocessed using coarse grinders like a knife mill to allow for efficient feeding in refiner mills without bridging and choking. Size reduction mechanical energy was directly measured for switchgrass (Panicum virgatum L.), wheat straw (Triticum aestivum L.), and corn stover (Zea mays L.) in an instrumented knife mill. Direct power inputs were determined for different knife mill screen openings from 12.7 to 50.8 mm, rotor speeds between 250 and 500 rpm, and mass feed rates from 1 to 11 kg/min. Overall accuracy of power measurement was calculated to be +/-0.003 kW. Total specific energy (kWh/Mg) was defined as size reduction energy to operate mill with biomass. Effective specific energy was defined as the energy that can be assumed to reach the biomass. The difference is parasitic or no-load energy of mill. Total specific energy for switchgrass, wheat straw, and corn stover chopping increased with knife mill speed, whereas, effective specific energy decreased marginally for switchgrass and increased for wheat straw and corn stover. Total and effective specific energy decreased with an increase in screen size for all the crops studied. Total specific energy decreased with increase in mass feed rate, but effective specific energy increased for switchgrass and wheat straw, and decreased for corn stover at increased feed rate. For knife mill screen size of 25.4 mm and optimum speed of 250 rpm, optimum feed rates were 7.6, 5.8, and 4.5 kg/min for switchgrass, wheat straw, and corn stover, respectively, and the corresponding total specific energies were 7.57, 10.53, and 8.87 kWh/Mg and effective specific energies were 1.27, 1.50, and 0.24 kWh/Mg for switchgrass, wheat straw, and corn stover, respectively. Energy utilization ratios were calculated as 16.8%, 14.3%, and 2.8% for switchgrass, wheat straw, and corn stover, respectively. These data will be useful for preparing the feed material for subsequent fine grinding operations and designing new mills.

  2. Assessing the specific energy consumption and physical properties of comminuted Douglas-fir chips for bioconversion

    Treesearch

    Yalan Liu; Jinwu Wang; Michael P. Wolcott

    2016-01-01

    Size reduction homogenizes the bulk biomass and facilitates downstream feedstock handling, transportation, and storage. Effects of feeding rate, mill-type (hammer and knife mill), screen size, and moisture content on comminution energy consumption of commercial Douglas-fir (Pseudotsuga menziesii) pulp chips were quantified. The resulting particles...

  3. Removing seed coat fragments with a lint cleaner grid bar air knife

    USDA-ARS?s Scientific Manuscript database

    Seed coat fragments (SCF) in ginned lint cause spinning problems at the textile mill and undesirable defects in finished goods. Work continued on developing an air knife that may help remove SCF from ginned lint. The air knife is mounted on the 1st lint cleaner grid bar of a saw-type lint cleaner,...

  4. Bulk density and compaction behavior of knife mill chopped switchgrass,wheat straw, and corn stover

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chevanan, Nehru; Womac, A.R.; Bitra, V.S.P.

    2009-08-01

    Bulk density of comminuted biomass significantly increased by vibration during handling and transportation, and by normal pressure during storage. Compaction characteristics affecting the bulk density of switchgrass, wheat straw, and corn stover chopped in a knife mill at different operating conditions and using four different classifying screens were studied. Mean loose-filled bulk densities were 67.5 18.4 kg/m3 for switchgrass, 36.1 8.6 kg/m3 for wheat straw, and 52.1 10.8 kg/m3 for corn stover. Mean tapped bulk densities were 81.8 26.2 kg/m3 for switchgrass, 42.8 11.7 kg/m3 for wheat straw, and 58.9 13.4 kg/m3 for corn stover. Percentage changes in compressibility duemore » to variation in particle size obtained from a knife mill ranged from 64.3 to 173.6 for chopped switchgrass, 22.2 51.5 for chopped wheat straw and 42.1 117.7 for chopped corn stover within the tested consolidation pressure range of 5 120 kPa. Pressure and volume relationship of chopped biomass during compression with application of normal pressure can be characterized by the Walker model and Kawakita and Ludde model. Parameter of Walker model was correlated to the compressibility with Pearson correlation coefficient greater than 0.9. Relationship between volume reduction in chopped biomass with respect to number of tappings studied using Sone s model indicated that infinite compressibility was highest for chopped switchgrass followed by chopped wheat straw and corn stover. Degree of difficulty in packing measured using the parameters of Sone s model indicated that the chopped wheat straw particles compacted very rapidly by tapping compared to chopped switchgrass and corn stover. These results are very useful for solving obstacles in handling bulk biomass supply logistics issues for a biorefinery.« less

  5. Bulk density and compaction behavior of knife mill chopped switchgrass, wheat straw, and corn stover.

    PubMed

    Chevanan, Nehru; Womac, Alvin R; Bitra, Venkata S P; Igathinathane, C; Yang, Yuechuan T; Miu, Petre I; Sokhansanj, Shahab

    2010-01-01

    Bulk density of comminuted biomass significantly increased by vibration during handling and transportation, and by normal pressure during storage. Compaction characteristics affecting the bulk density of switchgrass, wheat straw, and corn stover chopped in a knife mill at different operating conditions and using four different classifying screens were studied. Mean loose-filled bulk densities were 67.5+/-18.4 kg/m(3) for switchgrass, 36.1+/-8.6 kg/m(3) for wheat straw, and 52.1+/-10.8 kg/m(3) for corn stover. Mean tapped bulk densities were 81.8+/-26.2 kg/m(3) for switchgrass, 42.8+/-11.7 kg/m(3) for wheat straw, and 58.9+/-13.4 kg/m(3) for corn stover. Percentage changes in compressibility due to variation in particle size obtained from a knife mill ranged from 64.3 to 173.6 for chopped switchgrass, 22.2-51.5 for chopped wheat straw and 42.1-117.7 for chopped corn stover within the tested consolidation pressure range of 5-120 kPa. Pressure and volume relationship of chopped biomass during compression with application of normal pressure can be characterized by the Walker model and Kawakita and Ludde model. Parameter of Walker model was correlated to the compressibility with Pearson correlation coefficient greater than 0.9. Relationship between volume reduction in chopped biomass with respect to number of tappings studied using Sone's model indicated that infinite compressibility was highest for chopped switchgrass followed by chopped wheat straw and corn stover. Degree of difficulty in packing measured using the parameters of Sone's model indicated that the chopped wheat straw particles compacted very rapidly by tapping compared to chopped switchgrass and corn stover. These results are very useful for solving obstacles in handling bulk biomass supply logistics issues for a biorefinery.

  6. Biofuel manufacturing from woody biomass: effects of sieve size used in biomass size reduction.

    PubMed

    Zhang, Meng; Song, Xiaoxu; Deines, T W; Pei, Z J; Wang, Donghai

    2012-01-01

    Size reduction is the first step for manufacturing biofuels from woody biomass. It is usually performed using milling machines and the particle size is controlled by the size of the sieve installed on a milling machine. There are reported studies about the effects of sieve size on energy consumption in milling of woody biomass. These studies show that energy consumption increased dramatically as sieve size became smaller. However, in these studies, the sugar yield (proportional to biofuel yield) in hydrolysis of the milled woody biomass was not measured. The lack of comprehensive studies about the effects of sieve size on energy consumption in biomass milling and sugar yield in hydrolysis process makes it difficult to decide which sieve size should be selected in order to minimize the energy consumption in size reduction and maximize the sugar yield in hydrolysis. The purpose of this paper is to fill this gap in the literature. In this paper, knife milling of poplar wood was conducted using sieves of three sizes (1, 2, and 4 mm). Results show that, as sieve size increased, energy consumption in knife milling decreased and sugar yield in hydrolysis increased in the tested range of particle sizes.

  7. Process water reduction in a wire milling operation. 1989 summer intern report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alberg, J.

    1989-12-31

    Johnson Filtration Systems is a company located in New Brighton, Minnesota which employs 256 people. The focus of the project was to reduce the water usage of the wire milling operation. Water in the milling process is used to clean the wire and cool the mill components. Total annual water usage for this operation is six million gallons. The milling process changes the cross sectional shape of the wire by using flattening hammers and rollers. A synthetic coolant is used to enhance this process and remove heat. The coolant is removed from the wire as it is pulled through amore » squeegee, washed it with water and dried with an air knife.« less

  8. Development and application of a dry ultramicrotomy technique for the preparation of galvanneal sheet coatings.

    PubMed

    Barreto, M P; Veillette, R; L'Espérance, G

    1995-07-01

    The formability of galvanneal steel sheets used in the automotive industry is influenced by the presence and distribution of brittle and difficult to distinguish Zn-Fe intermetallics in the coating. Characterization of these intermetallics requires a high spatial resolution technique such as analytical transmission electron microscopy (ATEM). Sample preparation by ion milling is impossible due to iron redeposition, and traditional ultramicrotomy using water affects the coating chemistry. A technique based on dry ultramicrotomy has therefore been developed. To optimize the technique, different parameters (knife angle, cutting medium, thickness setting on the ultramicrotome, cutting speed) have been investigated for the preparation of galvanneal coatings and pure A1 sections. Results show that dry cutting does not affect the coating chemistry but shortens the life of the knife. Knife quality (cleanliness, sharpness and absence of defects) is a major factor to obtain good dry sections. The best results for the more ductile pure A1 are obtained with a 35 degrees knife whilst for the harder galvanneal coating it is recommended to use a 55 degrees knife. These results suggest that the sectioning mechanism for the harder material involves more a cleavage-fracture mechanism whilst a greater amount of shear is involved when sectioning relatively ductile A1. The optimum parameters for sectioning galvanneal coatings are established and results obtained by parallel electron energy loss spectrum imaging and energy dispersive X-ray spectrometry in the TEM are given. This study shows that with a good control of all the sectioning parameters it is possible to obtain good sections repeatedly and rapidly.

  9. Fluid mechanics relevant to flow through pretreatment of cellulosic biomass.

    PubMed

    Archambault-Léger, Véronique; Lynd, Lee R

    2014-04-01

    The present study investigates fluid mechanical properties of cellulosic feedstocks relevant to flow through (FT) pretreatment for biological conversion of cellulosic biomass. The results inform identifying conditions for which FT pretreatment can be implemented in a practical context. Measurements of pressure drop across packed beds, viscous compaction and water absorption are reported for milled and not milled sugarcane bagasse, switchgrass and poplar, and important factors impacting viscous flow are deduced. Using biomass knife-milled to pass through a 2mm sieve, the observed pressure drop was highest for bagasse, intermediate for switchgrass and lowest for poplar. The highest pressure drop was associated with the presence of more fine particles, greater viscous compaction and the degree of water absorption. Using bagasse without particle size reduction, the instability of the reactor during pretreatment above 140kg/m(3) sets an upper bound on the allowable concentration for continuous stable flow. Copyright © 2014. Published by Elsevier Ltd.

  10. 7 CFR 868.312 - Grade and grade requirements for the class Screenings Milled Rice. (See also § 868.315.)

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Milled Rice. (See also § 868.315.) 868.312 Section 868.312 Agriculture Regulations of the Department of... United States Standards for Milled Rice Principles Governing Application of Standards § 868.312 Grade and grade requirements for the class Screenings Milled Rice. (See also § 868.315.) Grades, Grade...

  11. 7 CFR 868.312 - Grade and grade requirements for the class Screenings Milled Rice. (See also § 868.315.)

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Milled Rice. (See also § 868.315.) 868.312 Section 868.312 Agriculture Regulations of the Department of... United States Standards for Milled Rice Principles Governing Application of Standards § 868.312 Grade and grade requirements for the class Screenings Milled Rice. (See also § 868.315.) Grades, Grade...

  12. Structural and Mechanical Properties of the ZrC/Ni-Nanodiamond Coating Synthesized by the PVD and Electroplating Processes for the Cutting Knifes

    NASA Astrophysics Data System (ADS)

    Chayeuski, V.; Zhylinski, V.; Cernashejus, O.; Visniakov, N.; Mikalauskas, G.

    2018-04-01

    In this work, combined gradient ZrC/Ni-nanodiamond ultradispersed diamonds (UDD) coatings were synthesized on the surface of knife blades made of hard alloy WC-2 wt.% Co by electroplating and cathode arc evaporation PVD techniques to increase the durability period of a wood-cutting milling tool. The microstructure, phase and elemental composition, microhardness, and adhesion strength of the coatings were investigated. Ni-UDD layer is not mixed with the ZrC coating and hard alloy substrate. Cobalt is present in Ni-UDD layer after deposition of ZrC. The ZrC/Ni-nanodiamond coating consists of separate phases of zirconium carbide (ZrC), α-Ni, and Ni-UDD. The maximum value of microhardness of the Ni-nanodiamond coating is 5.9 GPa. The microhardness value of the ZrC/Ni-nanodiamond coatings is 25 ± 6 GPa, which corresponds to the microhardness of the hard alloy substrate and ZrC coating. The obtained high values of the critical loads on the scratch track of the ZrC/Ni-nanodiamond coating in 24 N prove a sufficiently high value of the adhesion strength of the bottom Ni-UDD layer with WC-Co substrate. Pilot testing of ZrC/Ni-nanodiamond-coated cutting tools proved their increasing durability period to be 1.5-1.6 times higher than that of bare tools, when milling laminated chipboard.

  13. Development of candidate reference materials for the measurement of lead in bone

    PubMed Central

    Hetter, Katherine M.; Bellis, David J.; Geraghty, Ciaran; Todd, Andrew C.; Parsons, Patrick J.

    2010-01-01

    The production of modest quantities of candidate bone lead (Pb) reference materials is described, and an optimized production procedure is presented. The reference materials were developed to enable an assessment of the interlaboratory agreement of laboratories measuring Pb in bone; method validation; and for calibration of solid sampling techniques such as laser ablation ICP-MS. Long bones obtained from Pb-dosed and undosed animals were selected to produce four different pools of a candidate powdered bone reference material. The Pb concentrations of these pools reflect both environmental and occupational exposure levels in humans. The animal bones were harvested post mortem, cleaned, defatted, and broken into pieces using the brittle fracture technique at liquid nitrogen temperature. The bone pieces were then ground in a knife mill to produce fragments of 2-mm size. These were further ground in an ultra-centrifugal mill, resulting in finely powdered bone material that was homogenized and then sampled-scooped into vials. Testing for contamination and homogeneity was performed via instrumental methods of analysis. PMID:18421443

  14. 40 CFR 421.36 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... dried Lead .000 .000 Zinc .000 .000 Ammonia (as N) .000 .000 (b) Subpart C—Scrap Screening and Milling... per million pounds) of aluminum scrap screened and milled Lead .000 .000 Zinc .000 .000 Ammonia (as N... .000 Ammonia (as N) .000 .000 (d) Subpart C—Demagging Wet Air Pollution Control. PSNS Pollutant or...

  15. 40 CFR 421.36 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... dried Lead .000 .000 Zinc .000 .000 Ammonia (as N) .000 .000 (b) Subpart C—Scrap Screening and Milling... per million pounds) of aluminum scrap screened and milled Lead .000 .000 Zinc .000 .000 Ammonia (as N... .000 Ammonia (as N) .000 .000 (d) Subpart C—Demagging Wet Air Pollution Control. PSNS Pollutant or...

  16. 40 CFR 421.36 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... dried Lead .000 .000 Zinc .000 .000 Ammonia (as N) .000 .000 (b) Subpart C—Scrap Screening and Milling... per million pounds) of aluminum scrap screened and milled Lead .000 .000 Zinc .000 .000 Ammonia (as N... .000 Ammonia (as N) .000 .000 (d) Subpart C—Demagging Wet Air Pollution Control. PSNS Pollutant or...

  17. 40 CFR 421.36 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... dried Lead .000 .000 Zinc .000 .000 Ammonia (as N) .000 .000 (b) Subpart C—Scrap Screening and Milling... per million pounds) of aluminum scrap screened and milled Lead .000 .000 Zinc .000 .000 Ammonia (as N... .000 Ammonia (as N) .000 .000 (d) Subpart C—Demagging Wet Air Pollution Control. PSNS Pollutant or...

  18. 40 CFR 421.36 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... dried Lead .000 .000 Zinc .000 .000 Ammonia (as N) .000 .000 (b) Subpart C—Scrap Screening and Milling... per million pounds) of aluminum scrap screened and milled Lead .000 .000 Zinc .000 .000 Ammonia (as N... .000 Ammonia (as N) .000 .000 (d) Subpart C—Demagging Wet Air Pollution Control. PSNS Pollutant or...

  19. 40 CFR 795.70 - Indirect photolysis screening test: Sunlight photolysis in waters containing dissolved humic...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... (1985). (13) Mill T., Hendry D.G., Richardson H. “Free radical oxidants in natural waters.” Science, 207...)(7) of this section); peroxy radicals (RO2−) (Mill et al. (1981) under paragraph (f)(9) of this section; Mill et al. (1983) under paragraph (f)(8) of this section); hydroxyl radicals (HO−) (Mill et al...

  20. 40 CFR 795.70 - Indirect photolysis screening test: Sunlight photolysis in waters containing dissolved humic...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... (1985). (13) Mill T., Hendry D.G., Richardson H. “Free radical oxidants in natural waters.” Science, 207...)(7) of this section); peroxy radicals (RO2−) (Mill et al. (1981) under paragraph (f)(9) of this section; Mill et al. (1983) under paragraph (f)(8) of this section); hydroxyl radicals (HO−) (Mill et al...

  1. Particle size and shape distributions of hammer milled pine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Westover, Tyler Lott; Matthews, Austin Colter; Williams, Christopher Luke

    2015-04-01

    Particle size and shape distributions impact particle heating rates and diffusion of volatized gases out of particles during fast pyrolysis conversion, and consequently must be modeled accurately in order for computational pyrolysis models to produce reliable results for bulk solid materials. For this milestone, lodge pole pine chips were ground using a Thomas-Wiley #4 mill using two screen sizes in order to produce two representative materials that are suitable for fast pyrolysis. For the first material, a 6 mm screen was employed in the mill and for the second material, a 3 mm screen was employed in the mill. Bothmore » materials were subjected to RoTap sieve analysis, and the distributions of the particle sizes and shapes were determined using digital image analysis. The results of the physical analysis will be fed into computational pyrolysis simulations to create models of materials with realistic particle size and shape distributions. This milestone was met on schedule.« less

  2. 40 CFR 60.670 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... mineral processing plants: each crusher, grinding mill, screening operation, bucket elevator, belt... grinding mills at hot mix asphalt facilities that reduce the size of nonmetallic minerals embedded in... or grinding mills above ground; and wet material processing operations (as defined in § 60.671). (b...

  3. Accumulative Roll Bonding for Bladesmithing: From Book to Burrito to Blade

    NASA Astrophysics Data System (ADS)

    Hawgood, Mary; Hasier, John; Ho, Kathy

    2016-12-01

    A bladesmithing program was undertaken with the aim of producing superior decorative steel from dissimilar starting metals using severe plastic deformation. Accumulative roll bonding using an antiquated rolling mill was performed on 1095, CPM S30V, and 15N20 Hi-Contrast steel. Original attempts using the CPM S30V and the 1095 were unsuccessful, while later attempts using the 1095 and 15N20 Hi-Contrast steels produced a more desirable ingot. Characterization and testing, consisting of both optical and scanning electron microscopy, of the starting and wrought materials as well as the challenges in producing knife steel via synthesis of modern and traditional forging techniques, are discussed and failures analyzed.

  4. Fabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview.

    PubMed

    Goo, Chui Ling; Tan, Keson Beng Choon

    2017-01-01

    This report describes the clinical and technical aspects in the oral rehabilitation of an edentulous patient with knife-edge ridge at the mandibular anterior edentulous region, using implant-retained overdentures. The application of computer-aided design and computer-aided manufacturing (CAD/CAM) in the fabrication of the overdenture framework simplifies the laboratory process of the implant prostheses. The Nobel Procera CAD/CAM System was utilised to produce a lightweight titanium overdenture bar with locator attachments. It is proposed that the digital workflow of CAD/CAM milled implant overdenture bar allows us to avoid numerous technical steps and possibility of casting errors involved in the conventional casting of such bars.

  5. Investigation of the milling capabilities of the F10 Fine Grind mill using Box-Behnken designs.

    PubMed

    Tan, Bernice Mei Jin; Tay, Justin Yong Soon; Wong, Poh Mun; Chan, Lai Wah; Heng, Paul Wan Sia

    2015-01-01

    Size reduction or milling of the active is often the first processing step in the design of a dosage form. The ability of a mill to convert coarse crystals into the target size and size distribution efficiently is highly desirable as the quality of the final pharmaceutical product after processing is often still dependent on the dimensional attributes of its component constituents. The F10 Fine Grind mill is a mechanical impact mill designed to produce unimodal mid-size particles by utilizing a single-pass two-stage size reduction process for fine grinding of raw materials needed in secondary processing. Box-Behnken designs were used to investigate the effects of various mill variables (impeller, blower and feeder speeds and screen aperture size) on the milling of coarse crystals. Response variables included the particle size parameters (D10, D50 and D90), span and milling rate. Milled particles in the size range of 5-200 μm, with D50 ranging from 15 to 60 μm, were produced. The impeller and feeder speeds were the most critical factors influencing the particle size and milling rate, respectively. Size distributions of milled particles were better described by their goodness-of-fit to a log-normal distribution (i.e. unimodality) rather than span. Milled particles with symmetrical unimodal distributions were obtained when the screen aperture size was close to the median diameter of coarse particles employed. The capacity for high throughput milling of particles to a mid-size range, which is intermediate between conventional mechanical impact mills and air jet mills, was demonstrated in the F10 mill. Prediction models from the Box-Behnken designs will aid in providing a better guide to the milling process and milled product characteristics. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Grinding energy and physical properties of chopped and hammer-milled barley, wheat, oat, and canola straws

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J.S. Tumuluru; L.G. Tabil; Y. Song

    2014-01-01

    In the present study, specific energy for grinding and physical properties of wheat, canola, oat and barley straw grinds were investigated. The initial moisture content of the straw was about 0.13–0.15 (fraction total mass basis). Particle size reduction experiments were conducted in two stages: (1) a chopper without a screen, and (2) a hammer mill using three screen sizes (19.05, 25.4, and 31.75 mm). The lowest grinding energy (1.96 and 2.91 kWh t-1) was recorded for canola straw using a chopper and hammer mill with 19.05-mm screen size, whereas the highest (3.15 and 8.05 kWh t-1) was recorded for barleymore » and oat straws. The physical properties (geometric mean particle diameter, bulk, tapped and particle density, and porosity) of the chopped and hammer-milled wheat, barley, canola, and oat straw grinds measured were in the range of 0.98–4.22 mm, 36–80 kg m-3, 49–119 kg m-3, 600–1220 kg m-3, and 0.9–0.96, respectively. The average mean particle diameter was highest for the chopped wheat straw (4.22-mm) and lowest for the canola grind (0.98-mm). The canola grinds produced using the hammer mill (19.05-mm screen size) had the highest bulk and tapped density of about 80 and 119 kg m-3; whereas, the wheat and oat grinds had the lowest of about 58 and 88–90 kg m-3. The results indicate that the bulk and tapped densities are inversely proportional to the particle size of the grinds. The flow properties of the grinds calculated are better for chopped straws compared to hammer milled using smaller screen size (19.05 mm).« less

  7. Screening Adolescents in the Emergency Department for Weapon Carriage

    PubMed Central

    Cunningham, Rebecca M.; Resko, Stella M.; Harrison, Stephanie Roahen; Zimmerman, Marc; Stanley, Rachel; Chermack, Stephen T.; Walton, Maureen A.

    2010-01-01

    Objective To describe prevalence and correlates of past year weapon involvement among adolescents seeking care in an inner-city ED. Methods This cross-sectional study administered a computerized survey to all eligible adolescents (age 14–18), seven days a week seeking care in the ED over an 18 month period in an inner-city Level 1 ED. Validated measures were administered including measures of demographics, sexual activity, substance use, injury, violent behavior and weapon carriage/use. Results Adolescents (N=2069, 86% response rate) completed the computerized survey. 55% were female; 56.5% were African American. In the past year, 20% of adolescents reported knife/razor carriage, 7% reported gun carriage, and 6% pulled a knife/gun on someone; zero-inflated Poisson (ZIP) regression models were used to identify correlates of the occurrence and past year frequency of these weapon variables. Although gun carriage was more frequent among males, females were as likely to carry a knife or pull a weapon in the past year. Conclusions One fifth of all adolescent’s seeking care in this inner city ED have carried a weapon. Understanding weapon carriage among teens seeking ED care is a critical first step to future ED based injury prevention initiatives. PMID:20370746

  8. Gamma Knife Radiosurgery for Uveal Metastases: Report of Three Cases and a Review of the Literature.

    PubMed

    Ares, William J; Tonetti, Daniel; Yu, Jenny Y; Monaco, Edward A; Flickinger, John C; Lunsford, L Dade

    2017-02-01

    Uveal metastases are ophthalmologic tumors that have historically been treated by fractionated external beam radiation therapy or invasive brachytherapy. The need for rapid response and less invasive management options led the authors to explore the use of Gamma Knife stereotactic radiosurgery (SRS) for this common problem. Interventional case series. To prevent eye movement during the procedure, all 3 patients underwent a retrobulbar anesthetic block followed by magnetic resonance imaging to detect the target. All tumors were treated in a single procedure using the 4C or Perfexion Gamma Knife. The tumors received a minimal tumor dose of 14-20 Gy. Two patients also underwent SRS for additional intracranial metastases. At follow-up, performed between 4 and 15 months after SRS, all 3 patients demonstrated a reduction in uveal tumor volumes. One patient developed decreased visual acuity secondary to radiation retinopathy. In this early experience, SRS was found to be an effective management option for uveal metastases associated with systemic cancer. Patients can be screened and treated effectively early after diagnosis using a joint approach between ophthalmologists and neurosurgeons. Systemic oncologic care can continue without interruption. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Evaluation of a new disposable silicon limbal relaxing incision knife by experienced users.

    PubMed

    Albanese, John; Dugue, Geoffrey; Parvu, Valentin; Bajart, Ann M; Lee, Edwin

    2009-12-21

    Previous research has suggested that the silicon BD Atomic Edge knife has superior performance characteristics when compared to a metal knife and performance similar to diamond knife when making various incisions. This study was designed to determine whether a silicon accurate depth knife has equivalent performance characteristics when compared to a diamond limbal relaxing incision (LRI) knife and superior performance characteristics when compared to a steel accurate depth knife when creating limbal relaxing incision. Sixty-five ophthalmic surgeons with limbal relaxing incision experience created limbal relaxing incisions in ex-vivo porcine eyes with silicon and steel accurate depth knives and diamond LRI knives. The ophthalmic surgeons rated multiple performance characteristics of the knives on Visual Analog Scales. The observed differences between the silicon knife and diamond knife were found to be insignificant. The mean ratio between the performance of the silicon knife and the diamond knife was shown to be greater than 90% (with 95% confidence). The silicon knife's mean performance was significantly higher than the performance of the steel knife for all characteristics. (p-value < .05) For experienced users, the silicon accurate depth knife was found to be equivalent in performance to the diamond LRI knife and superior to the steel accurate depth knife when making limbal relaxing incisions in ex vivo porcine eyes. Disposable silicon LRI knives may be an alternative to diamond LRI knives.

  10. Usefulness of a novel slim type FlushKnife-BT over conventional FlushKnife-BT in esophageal endoscopic submucosal dissection.

    PubMed

    Ohara, Yoshiko; Toyonaga, Takashi; Hoshi, Namiko; Tanaka, Shinwa; Baba, Shinichi; Takihara, Hiroshi; Kawara, Fumiaki; Ishida, Tsukasa; Morita, Yoshinori; Umegaki, Eiji; Azuma, Takeshi

    2017-03-07

    To investigated the usefulness of a novel slim type ball-tipped FlushKnife (FlushKnife-BTS) over ball-tipped FlushKnife (FlushKnife-BT) in functional experiments and clinical practice. In order to evaluate the functionality of FlushKnife-BTS, water aspiration speed, resistance to knife insertion through the scope, and waterjet flushing speed were compared between FlushKnife-BTS and BT. In clinical practice, esophageal endoscopic submucosal dissection (ESD) performed using FlushKnife-BTS or BT by an experienced endoscopist between October 2015 and January 2016 were retrospectively reviewed. The treatment speed and frequency of removing and reinserting the knife to aspirate fluid and air during ESD sessions were analyzed. Functional experiments revealed that water aspiration speed by the endoscope equipped with a 2.8-mm working channel with FlushKnife-BTS was 7.7-fold faster than that with conventional FlushKnife-BT. Resistance to knife insertion inside the scope with a 2.8-mm working channel was reduced by 40% with FlushKnife-BTS. The waterjet flushing speed was faster with the use of FlushKnife-BT. In clinical practice, a comparison of 6 and 7 ESD using FlushKnife-BT and BTS, respectively, revealed that the median treatment speed was 25.5 mm 2 /min (range 19.6-30.3) in the BT group and 44.2 mm 2 /min (range 15.5-55.4) in the BTS group ( P = 0.0633). However, the median treatment speed was significantly faster with FlushKnife-BTS when the resection size was larger than 1000 m 2 ( n = 4, median 24.2 mm 2 /min, range 19.6-27.7 vs n = 4, median 47.4 mm 2 /min, range 44.2-55.4, P = 0.0209). The frequency of knife replacement was less in the BTS group (median 1.76 times in one hour, range 0-5.45) than in the BT group (7.02 times in one hour, range 4.23-15) ( P = 0.0065). Our results indicate that FlushKnife-BTS enhances the performance of ESD, particularly for large lesions, by improving air and fluid aspiration and knife insertion during ESD and reducing the frequency of knife removal and reinsertion.

  11. Usefulness of a novel slim type FlushKnife-BT over conventional FlushKnife-BT in esophageal endoscopic submucosal dissection

    PubMed Central

    Ohara, Yoshiko; Toyonaga, Takashi; Hoshi, Namiko; Tanaka, Shinwa; Baba, Shinichi; Takihara, Hiroshi; Kawara, Fumiaki; Ishida, Tsukasa; Morita, Yoshinori; Umegaki, Eiji; Azuma, Takeshi

    2017-01-01

    AIM To investigated the usefulness of a novel slim type ball-tipped FlushKnife (FlushKnife-BTS) over ball-tipped FlushKnife (FlushKnife-BT) in functional experiments and clinical practice. METHODS In order to evaluate the functionality of FlushKnife-BTS, water aspiration speed, resistance to knife insertion through the scope, and waterjet flushing speed were compared between FlushKnife-BTS and BT. In clinical practice, esophageal endoscopic submucosal dissection (ESD) performed using FlushKnife-BTS or BT by an experienced endoscopist between October 2015 and January 2016 were retrospectively reviewed. The treatment speed and frequency of removing and reinserting the knife to aspirate fluid and air during ESD sessions were analyzed. RESULTS Functional experiments revealed that water aspiration speed by the endoscope equipped with a 2.8-mm working channel with FlushKnife-BTS was 7.7-fold faster than that with conventional FlushKnife-BT. Resistance to knife insertion inside the scope with a 2.8-mm working channel was reduced by 40% with FlushKnife-BTS. The waterjet flushing speed was faster with the use of FlushKnife-BT. In clinical practice, a comparison of 6 and 7 ESD using FlushKnife-BT and BTS, respectively, revealed that the median treatment speed was 25.5 mm2/min (range 19.6-30.3) in the BT group and 44.2 mm2/min (range 15.5-55.4) in the BTS group (P = 0.0633). However, the median treatment speed was significantly faster with FlushKnife-BTS when the resection size was larger than 1000 m2 (n = 4, median 24.2 mm2/min, range 19.6-27.7 vs n = 4, median 47.4 mm2/min, range 44.2-55.4, P = 0.0209). The frequency of knife replacement was less in the BTS group (median 1.76 times in one hour, range 0-5.45) than in the BT group (7.02 times in one hour, range 4.23-15) (P = 0.0065). CONCLUSION Our results indicate that FlushKnife-BTS enhances the performance of ESD, particularly for large lesions, by improving air and fluid aspiration and knife insertion during ESD and reducing the frequency of knife removal and reinsertion. PMID:28321167

  12. 36. HISTORIC PHOTOGRAPH SHOWING BILL KEYS CLEANING UP AFTER THE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    36. HISTORIC PHOTOGRAPH SHOWING BILL KEYS CLEANING UP AFTER THE MILL RUN (NOTE SCREEN FROM MORTAR SETTING ON TABLE, STAMPS ARE HUNG UP). - Wall Street Gold Mill, Twentynine Palms, San Bernardino County, CA

  13. Efficacy of a Novel Narrow Knife with Water Jet Function for Colorectal Endoscopic Submucosal Dissection.

    PubMed

    Yoshida, Naohisa; Toyonaga, Takashi; Murakami, Takaaki; Hirose, Ryohei; Ogiso, Kiyoshi; Inada, Yutaka; Rani, Rafiz Abdul; Naito, Yuji; Kishimoto, Mitsuo; Ohara, Yoshiko; Azuma, Takeshi; Itoh, Yoshito

    2017-01-01

    With respect to the knife's design in colorectal endoscopic submucosal dissection (ESD), diameter, water jet function, and electric power are important because these relate to efficient dissection. In this study, we analyzed a novel, narrow ball tip-typed ESD knife with water jet function (Flush knife BT-S, diameter: 2.2 mm, length: 2000 mm, Fujifilm Co., Tokyo, Japan) compared to a regular diameter knife (Flush knife BT, diameter: 2.6 mm, length: 1800 mm). In laboratory and clinical research, electric power, knife insertion time, vacuum/suction amount with knife in the endoscopic channel, and water jet function were analyzed. We used a knife 2.0 mm long for BT-S and BT knives. The BT-S showed faster mean knife insertion time (sec) and better vacuum amount (ml/min) compared to the BT (insertion time: 16.7 versus 21.6, p < 0.001, vacuum amount: 38.0 versus 14.0, p < 0.01). Additionally, the water jet function of the BT-S was not inferior. In 39 colorectal ESD cases in two institutions, there were mean 4.7 times (range: 1-28) of knife insertion. Suction under knife happened 59% (23/39) and suction of fluid could be done in 100%. Our study showed that the narrow knife allows significantly faster knife insertion, better vacuum function, and effective clinical results.

  14. Ingenious laparoscopic knife.

    PubMed

    Goel, Rajiv; Modi, Pranjal

    2007-06-01

    Retroperitoneoscopic ureterolithotomy may be an option in selected group of patients. We present our cost effective, reliable ingenious laparoscopic knife of ureteric incision during retroperitoneoscopic ureterolithotomy. Ingenious laparoscopic knife is made by firmly tying stab knife to 5 mm laparoscopic instrument. This knife is passed through 10-mm renal angle port for making ureteric incision. Ingenious laparoscopic knife has been successfully used in 22 patients with no intraoperative and postoperative complications. Ingenious laparoscopic knife is cost effective, reliable instrument for ureteric incision during retroperitoneoscopic ureterolithotomy.

  15. Efficacy of a Novel Narrow Knife with Water Jet Function for Colorectal Endoscopic Submucosal Dissection

    PubMed Central

    Inada, Yutaka; Rani, Rafiz Abdul; Naito, Yuji; Azuma, Takeshi; Itoh, Yoshito

    2017-01-01

    Backgrounds With respect to the knife's design in colorectal endoscopic submucosal dissection (ESD), diameter, water jet function, and electric power are important because these relate to efficient dissection. In this study, we analyzed a novel, narrow ball tip-typed ESD knife with water jet function (Flush knife BT-S, diameter: 2.2 mm, length: 2000 mm, Fujifilm Co., Tokyo, Japan) compared to a regular diameter knife (Flush knife BT, diameter: 2.6 mm, length: 1800 mm). Methods In laboratory and clinical research, electric power, knife insertion time, vacuum/suction amount with knife in the endoscopic channel, and water jet function were analyzed. We used a knife 2.0 mm long for BT-S and BT knives. Results The BT-S showed faster mean knife insertion time (sec) and better vacuum amount (ml/min) compared to the BT (insertion time: 16.7 versus 21.6, p < 0.001, vacuum amount: 38.0 versus 14.0, p < 0.01). Additionally, the water jet function of the BT-S was not inferior. In 39 colorectal ESD cases in two institutions, there were mean 4.7 times (range: 1–28) of knife insertion. Suction under knife happened 59% (23/39) and suction of fluid could be done in 100%. Conclusions Our study showed that the narrow knife allows significantly faster knife insertion, better vacuum function, and effective clinical results. PMID:29081793

  16. 1. VIEW OF SUPERINTENDENT'S HOUSE ON ROUTE 29, LOOKING SOUTHWEST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. VIEW OF SUPERINTENDENT'S HOUSE ON ROUTE 29, LOOKING SOUTHWEST. THIS TWO-STORY, HIPPED-ROOF STRUCTURE WITH A CENTRAL HALL AND CHIMNEY WAS CONSTRUCTED FOR THE SUPERINTENDENT OF STARK MILL, NEW ENGLAND SOUTHERN MILLS IN 1923-24. THE MILL ENGINEERS, LOCKWOOD GREENE COMPANY, ALSO DESIGNED AND BUILT THE NEW MILL HOUSING. THIS HOUSE HAS SEVEN ROOMS, BATH, SCREENED OUTSIDE PORCH AND SLEEPING PORCH, AND GARAGE. IT COST APPROXIMATELY $9,000. - Superintendent's House, Southwest corner of Routes 29 & 100, Hogansville, Troup County, GA

  17. Dual centrifugation - A new technique for nanomilling of poorly soluble drugs and formulation screening by an DoE-approach.

    PubMed

    Hagedorn, Martin; Bögershausen, Ansgar; Rischer, Matthias; Schubert, Rolf; Massing, Ulrich

    2017-09-15

    The development of nanosuspensions of poorly soluble APIs takes a lot of time and high amount of active material is needed. In this publication the use of dual centrifugation (DC) for an effective and rapid API-nanomilling is described for the first time. DC differs from normal centrifugation by an additional rotation of the samples during centrifugation, resulting in a very fast and powerful movement of the samples inside the vials, which - in combination with milling beads - result in effective milling. DC-nanomilling was compared to conventional wet ball milling and results in same or even smaller particle sizes. Also drug concentrations up to 40% can be processed. The process is fast (typical 90min) and the temperature can be controlled. DC-nanomilling appears to be very gentle, experiments showed no change of the crystal structure during milling. Since batch sizes are very small (100-1000mg) and since 40 sample vials can be processed in parallel, DC is ideal for the screening of suitable polymer/surfactant combinations. Fenofibrate was used to investigate DC-nanomilling for formulation screening by applying a DoE-approach. The presented data also show that the results of DC-nanomilling experiments are highly comparable to the results obtained by common agitator mills. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Screening adolescents in the emergency department for weapon carriage.

    PubMed

    Cunningham, Rebecca M; Resko, Stella M; Harrison, Stephanie Roahen; Zimmerman, Marc; Stanley, Rachel; Chermack, Stephen T; Walton, Maureen A

    2010-02-01

    The objective was to describe the prevalence and correlates of past-year weapon involvement among adolescents seeking care in an inner-city emergency department (ED). This cross-sectional study administered a computerized survey to all eligible adolescents (age 14-18 years), 7 days a week, who were seeking care over an 18-month period at an inner-city Level 1 ED. Validated measures were administered, including measures of demographics, sexual activity, substance use, injury, violent behavior, weapon carriage, and/or weapon use. Zero-inflated Poisson (ZIP) regression models were used to identify correlates of the occurrence and past-year frequency of these weapons variables. Adolescents (n = 2069, 86% response rate) completed the computerized survey. Fifty-five percent were female; 56.5% were African American. In the past year, 20% of adolescents reported knife or razor carriage, 7% reported gun carriage, and 6% pulled a knife or gun on someone. Although gun carriage was more frequent among males, females were as likely to carry a knife or pull a weapon in the past year. One-fifth of all adolescents seeking care in this inner-city ED have carried a weapon. Understanding weapon carriage among teens seeking ED care is a critical first step to future ED-based injury prevention initiatives. (c) 2010 by the Society for Academic Emergency Medicine.

  19. Eco-friendly rubberized cotton fabric roller for ginning machines.

    PubMed

    Iyer, G V

    2007-01-01

    This article discusses the pollution caused by chrome composite leather-clad (CCLC) rollers commonly used in cotton roller ginning mills and suggests an alternative roller material. CCLC rollers contain about 18,000 to 36,000 mg/kg (ppm) total chromium in trivalent and hexavalent forms, which are toxic to human health and carcinogenic. When seed-cotton is processed in double roller (DR) ginning machines, the lint is contaminated with chromium, and chromium particles are carried into the spun yarns and cotton by-products. Specifically, due to persistent rubbing of the leather-clad roller over the stationary knife during the ginning process, the lint is contaminated with about 140 to 1990 ppm of chromium, and the spun yarns and cotton by-products contain about 100 to 200 ppm, far in excess of the standard limit of 0.1 ppm. Gin and mill workers are directly exposed to this carcinogenic substance. To offset this problem, pollution-free rubberized cotton fabric (RCF) rollers have been fabricated and tested in roller gins. The RCF roller covering is made of multiple layers of fabric bonded together using a white rubber compound, which has a surface finish conducive to high ginning efficiency. This eliminates chromium contamination and pollution during the ginning process. On the basis of the design and development of various test rollers and subsequent evaluation studies, the performance of pollution-free RCF rollers has been demonstrated with reference to their commercial benefit and eco-friendliness in cotton ginning mills.

  20. Feasibility Study on Applying Radiophotoluminescent Glass Dosimeters for CyberKnife SRS Dose Verification

    PubMed Central

    Hsu, Shih-Ming; Hung, Chao-Hsiung; Liao, Yi-Jen; Fu, Hsiao-Mei; Tsai, Jo-Ting

    2017-01-01

    CyberKnife is one of multiple modalities for stereotactic radiosurgery (SRS). Due to the nature of CyberKnife and the characteristics of SRS, dose evaluation of the CyberKnife procedure is critical. A radiophotoluminescent glass dosimeter was used to verify the dose accuracy for the CyberKnife procedure and validate a viable dose verification system for CyberKnife treatment. A radiophotoluminescent glass dosimeter, thermoluminescent dosimeter, and Kodak EDR2 film were used to measure the lateral dose profile and percent depth dose of CyberKnife. A Monte Carlo simulation for dose verification was performed using BEAMnrc to verify the measured results. This study also used a radiophotoluminescent glass dosimeter coupled with an anthropomorphic phantom to evaluate the accuracy of the dose given by CyberKnife. Measurements from the radiophotoluminescent glass dosimeter were compared with the results of a thermoluminescent dosimeter and EDR2 film, and the differences found were less than 5%. The radiophotoluminescent glass dosimeter has some advantages in terms of dose measurements over CyberKnife, such as repeatability, stability, and small effective size. These advantages make radiophotoluminescent glass dosimeters a potential candidate dosimeter for the CyberKnife procedure. This study concludes that radiophotoluminescent glass dosimeters are a promising and reliable dosimeter for CyberKnife dose verification with clinically acceptable accuracy within 5%. PMID:28046056

  1. [Research progress of needles with knife-edge for carotid cardiac syndrome].

    PubMed

    Tan, Lingqiong; Zhao, Yanling

    2015-04-01

    According to topographic anatomy, pathogenesis and by retrieving, summarizing and analyzing literature regarding needle-knife and needles with knife-edge for carotid cardiac syndrome, it is found out that clinical misdiagnosis rate of carotid cardiac syndrome is considerably high. Needle-knife and needles with knife-edge could significantly improve the clinical symptoms of carotid cardiac syndrome, showing characteristic and advantage in treatment, but it is deficient in technique standard and efficacy criteria that should be united and authoritative. Researches regarding pathogenesis of carotid cardiac syndrome are not systematic. Clinical observation regarding long-term efficacy and relapse of needle-knife and needles with knife-edge treatment is rare. It is believed that the awareness on carotid cardiac syndrome should be increased to reduce misdiagnosis; scientific and standardized technique standard and efficacy criteria should be established; systematic and comprehensive researches regarding mechanism of needle-knife and needles with knife-edge for carotid cardiac syndrome should be launched; besides, clinical discussion regarding its long-term efficacy should start to provide a better clinical guideline.

  2. [Design and application of silver needle-knife].

    PubMed

    Sun, Guodong; Shi, Bin; Zhang, Benwu; Xu, Haidong

    2015-04-01

    A silver needle-knife which has the dual function of silver needle and needle-knife is designed. The main components of this silver needle-knife are approximately 50% silver and approximately 50% nichrome. The silver needle-knife is composed of five parts, including needle-knife tail, spiral handle; steering handle, needle-knife body and needle-knife edge. It converges the advantages of needle-knife and silver needle, which can cut loose of diseased tissue and peel adhesion of lesions, but also be heated with moxa cone and thermal therapeutic instrument, and connect with electroacupuncture apparatus. It has the function of warming channel and removing coldness, dispelling wind and eliminating dampness, resolving spasm and relieving pain, dredging the channel and so on. Due to the spiral handle and the steering handle, the operation is easier, which reduces the blindness of cutting and increase the safety. It is mainly used for soft tissue injury, rheumatism and rheumatoid arthritis, as well as degenerative diseases of spine and joint, and it has obvious efficacy on some internal medical diseases.

  3. 42. VIEW OF SYMONS 3 BY 6 FEET VIBRATING SCREEN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    42. VIEW OF SYMONS 3 BY 6 FEET VIBRATING SCREEN FROM NORTHWEST. SCREEN IS BELOW AND FED BY DINGS MAGNETIC PULLEY - DRIVE GEAR VISIBLE. - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD

  4. Evaluation of Paulownia elongata wood polyethylene composites

    USDA-ARS?s Scientific Manuscript database

    Paulownia wood flour (PWF), a byproduct of milling lumber, was employed as a bio-filler and blended with high density polyethylene (HDPE) via extrusion. Paulownia wood (PW) shavings were milled through a 1-mm screen then separated via shaking into various particle fractions using sieves (#30 - < #2...

  5. In Situ Measurement of Ground-Surface Flow Resistivity

    NASA Technical Reports Server (NTRS)

    Zuckerwar, A. J.

    1984-01-01

    New instrument allows in situ measurement of flow resistivity on Earth's ground surface. Nonintrusive instrument includes specimen holder inserted into ground. Flow resistivity measured by monitoring compressed air passing through flow-meters; pressure gages record pressure at ground surface. Specimen holder with knife-edged inner and outer cylinders easily driven into ground. Air-stream used in measuring flow resistivity of ground enters through quick-connect fitting and exits through screen and venthole.

  6. No need to change the skin knife in modern arthroplasty surgery.

    PubMed

    Ottesen, C; Skovby, A; Troelsen, A; Specht, C; Friis-Møller, A; Husted, H

    2014-08-01

    Earlier studies have found varying contamination rates using separate skin and deep knives in total hip (THA) and total knee (TKA) arthroplasty surgery. Previous studies were primarily conducted in the setting of concomitant use of laminar airflow and/or plastic adhesive draping. This has lead to conflicting conclusions regarding discarding the skin knife or not. This study evaluates the prevalence of contamination of a separate skin knife using modern antiseptic technique in primary THA and TKA without laminar airflow. Three knives from each primary THA and TKA surgery in non-laminar airflow operating rooms were collected: one used for the skin, one used for deeper tissues and one control knife. A total of 831 knife blades from 277 patients were cultured 12 days. Contamination of the skin knife was found in eight patients (2.8 %), contamination of the "deep" knife in five patients (1.8 %) and contamination of the control knife in five patients (1.8 %). No patient developed an infection with 1-year follow-up. Our findings suggest a very low rate of contamination of the skin knife using modern antiseptic technique without laminar airflow and/or plastic adhesive draping and do not support the use of a separate skin knife in arthroplasty surgery.

  7. Hemochromatosis detection in a health screening program at an Alabama forest products mill.

    PubMed

    Barton, James C; Cheatwood, Susan M; Key, Timothy J; Acton, Ronald T

    2002-08-01

    We analyzed hemochromatosis detection in a 11.5-year multiphasic health screening program at a forest products mill. There were 2199 participants: 2032 Whites (1506 men, 526 women) and 167 African Americans (124 men, 43 women); 85.0% of employees were screened. Iron and transferrin saturation were measured in a serum biochemistry profile on specimens obtained after overnight fasting; ferritin was measured in participants with elevated iron concentrations or transferrin saturation > 48%. Participants with elevated ferritin levels underwent further evaluation. Eight White men were diagnosed to have hemochromatosis (frequency 0.0039 in Whites, 0.0053 in White men). The estimated cost per case detected was $8826. Family members of two participants with hemochromatosis were also diagnosed to have hemochromatosis or iron overload. We conclude that detecting hemochromatosis in a workplace multiphasic health screening program is efficacious and economical.

  8. Maintaining knife sharpness in industrial meat cutting: A matter of knife or meat cutter ability.

    PubMed

    Karltun, J; Vogel, K; Bergstrand, M; Eklund, J

    2016-09-01

    Knife sharpness is imperative in meat cutting. The aim of this study was to compare the impact of knife blade steel quality with meat cutters' individual ability to maintain the cutting edge sharp in an industrial production setting. Twelve meat cutters in two different companies using three different knives during normal production were studied in this quasi-experimental study. Methods included were measuring knife cutting force before and after knife use, time knives were used, ratings of sharpness and discomfort and interviews. Results showed that the meat cutters' skill of maintaining sharpness during work had a much larger effect on knife sharpness during work than the knife steel differences. The ability was also related to feelings of discomfort and to physical exertion. It was found that meat cutters using more knives were more likely to suffer from discomfort in the upper limbs, which is a risk for developing MSD. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Comparison of full width at half maximum and penumbra of different Gamma Knife models.

    PubMed

    Asgari, Sepideh; Banaee, Nooshin; Nedaie, Hassan Ali

    2018-01-01

    As a radiosurgical tool, Gamma Knife has the best and widespread name recognition. Gamma Knife is a noninvasive intracranial technique invented and developed by Swedish neurosurgeon Lars Leksell. The first commercial Leksell Gamma Knife entered the therapeutic armamentarium at the University of Pittsburgh in the United States on August 1987. Since that time, different generation of Gamma Knife developed. In this study, the technical points and dosimetric parameters including full width at half maximum and penumbra on different generation of Gamma Knife will be reviewed and compared. The results of this review study show that the rotating gamma system provides a better dose conformity.

  10. 21 CFR 886.4230 - Ophthalmic knife test drum.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic knife test drum. 886.4230 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4230 Ophthalmic knife test drum. (a) Identification. An ophthalmic knife test drum is a device intended to test the keenness of ophthalmic surgical...

  11. Cross-Grain Knife Planing Improves Surface Quality and Utilization of Aspen

    Treesearch

    Harold A. Stewart

    1971-01-01

    Aspen at 6 percent moisture content was planed parallel to the grain and across the grain on a cabinet planer with a 25? rake angle, 1/16- and 1/32-inch depth of cut, and 20 knife marks per inch. Aspen was also cross-grain knife planed with a 45? rake angle, 1/32-, 1/16-, and 1/8-inch depths of cut, and 20, 10, 5, and 2.5 knife marks per inch. Cross-grain knife...

  12. Penetration tests to study the mechanical tribological properties of chisel type knife

    NASA Astrophysics Data System (ADS)

    Vlăduţoiu, L.; Chişiu, G.; Andrei, T.; Predescu, A.; Muraru, C.; Vlăduţ, V.

    2017-02-01

    The goal of this study was to analyze the behaviour of chisel knife type penetration in a certain type of sand. A series of penetration tests were carried out with chisel knife type, the answer to penetration depending mainly on nature, shape, size of knife and operating parameters such as speed, depth and working conditions. Tests were conducted in work conditions with wet sand and dry sand and determined force of resistance to penetration of the chisel knife type to a certain depth.

  13. 51. VIEW OF CRUSHER ADDITION FROM EAST. SHOWS BAKER COOLER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    51. VIEW OF CRUSHER ADDITION FROM EAST. SHOWS BAKER COOLER AT LOWER LEFT, AND FOUNDATIONS FOR ROD MILL BETWEEN COOLER AND STEPHENS-ADAMSON INCLINED BUCKET ELEVATOR. THE BELT CONVEYOR TO RIGHT OF ELEVATOR FED ELEVATOR FROM ROD MILL. 100-TON ORE BIN AND DUST COLLECTOR IS BEHIND FRAMING BENT. NOTE CONVEYOR EMERGING FROM BOTTOM OF ORE BIN, THIS AND THE INCLINED ELEVATOR FED THE SYMONS SCREEN (MISSING). - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD

  14. Palliation of Postintubation Tracheal Stenosis Using Insulation-Tipped Diathermic Knife 2: A Case Report

    PubMed Central

    Yoon, Seon Bin; Park, Yong Won; Cheon, Mi Ju; Koh, Young Min; Park, Sanghoon; Kim, Se Joong; Lee, Seung Hyeun

    2015-01-01

    Objective To report the first case of using the insulation-tipped diathermic knife 2 (IT knife-2) for the treatment of postintubation tracheal stenosis. Clinical Presentation and Intervention A 71-year-old female patient with a history of endotracheal intubation 3 years earlier presented with throat discomfort, gross wheezing and dyspnea. Chest imaging and bronchoscopy demonstrated a strand-like tracheal stenosis in the upper trachea. The IT knife-2 was used to treat the patient and the lesion was palliated without complication. Conclusion This case was successfully treated with the IT knife-2 and thus implies a potential usefulness of the IT knife-2 as a new modality for bronchoscopic intervention. PMID:26390388

  15. A Genetic Linkage Map of Longleaf Pine (Pinus palustris Mill.) Based on Random Amplified Polymorphic DNAs

    Treesearch

    C.D. Nelson; Thomas L. Kubisiak; M. Stine; W.L. Nance

    1994-01-01

    Eight megagametophyte DNA samples from a single longleaf pine (Pinus palustris Mill.) tree were used to screen 576 oligonucleotide primers for random amplified polymorphic DNA (RAPD) fragments. Primers amplifying repeatable polymorphic fragments were further characterized within a sample of 72 megagametophytes from the same tree. Fragments...

  16. 167. VIEW OF DUST COLLECTOR AND CRUSHED OXIDIZED ORE BIN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    167. VIEW OF DUST COLLECTOR AND CRUSHED OXIDIZED ORE BIN FROM EAST. THE DUCTWORK TO TOP OF COLLECTOR (OPEN END, MIDDLE LEFT) CONNECTED TO HOODS OVER SYMONS SCREEN, ROD MILL, AND BAKER COOLER DISCHARGE - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD

  17. 52. VIEW OF DUST COLLECTOR AND CRUSHED OXIDIZED ORE BIN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    52. VIEW OF DUST COLLECTOR AND CRUSHED OXIDIZED ORE BIN FROM EAST. THE DUCTWORK TO TOP OF COLLECTOR (OPEN END, MIDDLE LEFT) CONNECTED TO HOODS OVER SYMONS SCREEN, ROD MILL, AND BAKER COOLER DISCHARGE. - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD

  18. 19 CFR 12.95 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... handle of the knife, or any knife with a blade which opens automatically by operation of inertia, gravity... button or device in the handle of the knife or by operation of inertia, gravity, or both; (3) Unassembled... handle of the knife or by operation of inertia, gravity, or both; or (4) Knives with a detachable blade...

  19. 19 CFR 12.95 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... handle of the knife, or any knife with a blade which opens automatically by operation of inertia, gravity... button or device in the handle of the knife or by operation of inertia, gravity, or both; (3) Unassembled... handle of the knife or by operation of inertia, gravity, or both; or (4) Knives with a detachable blade...

  20. 19 CFR 12.95 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... handle of the knife, or any knife with a blade which opens automatically by operation of inertia, gravity... button or device in the handle of the knife or by operation of inertia, gravity, or both; (3) Unassembled... handle of the knife or by operation of inertia, gravity, or both; or (4) Knives with a detachable blade...

  1. 19 CFR 12.95 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... handle of the knife, or any knife with a blade which opens automatically by operation of inertia, gravity... button or device in the handle of the knife or by operation of inertia, gravity, or both; (3) Unassembled... handle of the knife or by operation of inertia, gravity, or both; or (4) Knives with a detachable blade...

  2. 19 CFR 12.95 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... handle of the knife, or any knife with a blade which opens automatically by operation of inertia, gravity... button or device in the handle of the knife or by operation of inertia, gravity, or both; (3) Unassembled... handle of the knife or by operation of inertia, gravity, or both; or (4) Knives with a detachable blade...

  3. The gamma knife in ophthalmology. Part One--Uveal melanoma.

    PubMed

    Wygledowska-Promieńska, Dorota; Jurys, Małgorzata; Wilczyński, Tomasz; Drzyzga, Łukasz

    2014-01-01

    The Gamma Knife was designed by Lars Leksell in the early 1950's. It gave rise to a new discipline of medicine--stereotactic radiosurgery. Primarily dedicated to neurosurgery, the Gamma Knife has become an alternative, widely used surgery technique. According to Elekta's statistics, approximately 60,000 people are treated with Leksell Gamma Knife every year and it is the most extensively studied stereotactic radiosurgery system in the world. The Leksell Gamma Knife can also be used in ophthalmology. The gamma ray beam concentration enables effective treatment of uveal melanoma, choroidal hemangioma, orbital tumors or even choroidal neovascularization. The virtue of Leksell Gamma Knife is its extreme precision, non-invasiveness and the possibility of outpatient treatment, which significantly reduces costs and diminishes post-operative complications. Innovative solutions shorten a single session to a minimum, which is very comfortable and safe for both staff and patients. Advantages and possible side effects of gamma knife radiosurgery are well-documented in the professional literature. The objective of this review is to present the recognized applications of Leksell Gamma Knife in ophthalmology.

  4. Embolization with Gamma Knife Radiosurgery of Giant Intracranial Arteriovenous Malformations.

    PubMed

    Chun, Dong Hyun; Kim, Moo Seong; Kim, Sung Tae; Paeng, Sung Hwa; Jeong, Hae Woong; Lee, Won Hee

    2016-01-01

    Giant arteriovenous malformations (i.e., those greater than 6 cm maximum diameter or volume > 33 cc) are difficult to treat and often carry higher treatment morbidity and mortality rates. In our study, we reviewed the angiographic results and clinical outcomes for 11 patients with giant arteriovenous malformations who were treated between 1994 and 2012. The patients selected included 9 males (82%) and 2 females (18%). Their presenting symptoms were hemorrhage (n=2; 18%), seizure (n=7; 64%), and headache (n=2; 12%). Nine patients were Spetzler-Martin Grade III, 2 were Spetzler-Martin Grade IV. The mean arteriovenous malformation volume was 41 cc (33-52 cc). The mean age of the patients was 45.1 years (24-57 years) and the mean radiation dose delivered to the margin of the nidus was 14.2 Gy. Ten patients received pre-Gamma Knife radiosurgery embolization and Gamma Knife radiosurgery, 1 patient received pre-Gamma Knife radiosurgery embolization and Gamma Knife radiosurgery twice and the interval between Gamma Knife radiosurgeries was 3 months. The complete obliteration rate following Gamma Knife radiosurgery was 36%, subtotal obliteration ( > 70% decreased size of nidus) was 36%, and partial obliteration was 28%. One patient experienced a small hemorrhage after embolization. Combined embolization and Gamma Knife radiosurgery showed successful obliteration of the arteriovenous malformation nidus. The use of embolization to initially reduce nidus size followed by Gamma Knife radiosurgery improves the treatment results. Repeated Gamma Knife radiosurgery should be a treatment option when there is a small nidus remnant.

  5. Iridium-Knife: Another knife in radiation oncology.

    PubMed

    Milickovic, Natasa; Tselis, Nikolaos; Karagiannis, Efstratios; Ferentinos, Konstantinos; Zamboglou, Nikolaos

    Intratarget dose escalation with superior conformity is a defining feature of three-dimensional (3D) iridium-192 ( 192 Ir) high-dose-rate (HDR) brachytherapy (BRT). In this study, we analyzed the dosimetric characteristics of interstitial 192 Ir HDR BRT for intrathoracic and cerebral malignancies. We examined the dose gradient sharpness of HDR BRT compared with that of linear accelerator-based stereotactic radiosurgery and stereotactic body radiation therapy, usually called X-Knife, to demonstrate that it may as well be called a Knife. Treatment plans for 10 patients with recurrent glioblastoma multiforme or intrathoracic malignancies, five of each entity, treated with X-Knife (stereotactic radiosurgery for glioblastoma multiforme and stereotactic body radiation therapy for intrathoracic malignancies) were replanned for simulated HDR BRT. For 3D BRT planning, we used identical structure sets and dose prescription as for the X-Knife planning. The indices for qualitative treatment plan analysis encompassed planning target volume coverage, conformity, dose falloff gradient, and the maximum dose-volume limits to different organs at risk. Volume coverage in HDR plans was comparable to that calculated for X-Knife plans with no statistically significant difference in terms of conformity. The dose falloff gradient-sharpness-of the HDR plans was considerably steeper compared with the X-Knife plans. Both 3D 192 Ir HDR BRT and X-Knife are effective means for intratarget dose escalation with HDR BRT achieving at least equal conformity and a steeper dose falloff at the target volume margin. In this sense, it can reasonably be argued that 3D 192 Ir HDR BRT deserves also to be called a Knife, namely Iridium-Knife. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  6. Dynamic gamma knife radiosurgery

    NASA Astrophysics Data System (ADS)

    Luan, Shuang; Swanson, Nathan; Chen, Zhe; Ma, Lijun

    2009-03-01

    Gamma knife has been the treatment of choice for various brain tumors and functional disorders. Current gamma knife radiosurgery is planned in a 'ball-packing' approach and delivered in a 'step-and-shoot' manner, i.e. it aims to 'pack' the different sized spherical high-dose volumes (called 'shots') into a tumor volume. We have developed a dynamic scheme for gamma knife radiosurgery based on the concept of 'dose-painting' to take advantage of the new robotic patient positioning system on the latest Gamma Knife C™ and Perfexion™ units. In our scheme, the spherical high dose volume created by the gamma knife unit will be viewed as a 3D spherical 'paintbrush', and treatment planning reduces to finding the best route of this 'paintbrush' to 'paint' a 3D tumor volume. Under our dose-painting concept, gamma knife radiosurgery becomes dynamic, where the patient moves continuously under the robotic positioning system. We have implemented a fully automatic dynamic gamma knife radiosurgery treatment planning system, where the inverse planning problem is solved as a traveling salesman problem combined with constrained least-square optimizations. We have also carried out experimental studies of dynamic gamma knife radiosurgery and showed the following. (1) Dynamic gamma knife radiosurgery is ideally suited for fully automatic inverse planning, where high quality radiosurgery plans can be obtained in minutes of computation. (2) Dynamic radiosurgery plans are more conformal than step-and-shoot plans and can maintain a steep dose gradient (around 13% per mm) between the target tumor volume and the surrounding critical structures. (3) It is possible to prescribe multiple isodose lines with dynamic gamma knife radiosurgery, so that the treatment can cover the periphery of the target volume while escalating the dose for high tumor burden regions. (4) With dynamic gamma knife radiosurgery, one can obtain a family of plans representing a tradeoff between the delivery time and the dose distributions, thus giving the clinician one more dimension of flexibility of choosing a plan based on the clinical situations.

  7. Usefulness of IT knife nano for endoscopic submucosal dissection of large colo-rectal lesions.

    PubMed

    Suzuki, T; Hara, T; Kitagawa, Y; Yamaguchi, T

    2016-01-01

    Endoscopic submucosal dissection (ESD) is currently widely conducted for the treatment of early gastrointestinal -cancers. Due to the characteristic anatomy of the large intestine, needle- tip type devices such as Dual knife are mainly used in colorectal ESD. On the other hand, the non- needle-tip type IT knife is a unique device with an insulated tip, and has been reported to be safe, efficacious and speedy when used in gastric ESD. A new model of IT knife, IT knife nano, anticipated to be useful for esophageal and colorectal ESD has become available, but its usefulness has not been reported. Therefore, we performed this study to evaluate the usefulness of IT knife nano for ESD of large colorectal lesions. Previous studies have shown that a tumor size of 40 mm or above significantly prolongs treatment time and is a factor of treatment difficulty. We selected colorectal lesions of 40 mm and above, and compared 32 lesions treated with Dual knife alone before IT knife nano was available (No-IT group) and 40 cases treated with IT knife nano as a second knife after IT knife nano became available (IT group). We assessed en bloc resection rate, complete en bloc resection rate, complication rate and treatment time. The en bloc resection rates in No-IT group and IT group were 100% and 97.5%, respectively, with no significant difference. The respective median treatment time was 70 min and 51 min, and was significantly shortened in IT group (P < 0.05). The respective rates of procedure- related perforation were 3.1% and 0% ; in IT group suggesting a tendency of reduced incidence. Use of IT knife nano in ESD for large colorectal -lesions achieves the same levels of efficacy and safety as conventional device, with the additional merit of shortening treatment time. © Acta Gastro-Enterologica Belgica.

  8. Angiomatous lesion and delayed cyst formation after gamma knife surgery for intracranial meningioma: case report and review of literatures.

    PubMed

    Liu, Zhiyong; He, Min; Chen, Hongxu; Liu, Yi; Li, Qiang; Li, Lin; Li, Jin; Chen, Haifeng; Xu, Jianguo

    2015-01-01

    Gamma Knife has become a major therapeutic method for intracranial meningiomas, vascular malformations and schwannomas with exact effect. In recent years an increasing number of delayed complications after Gamma Knife surgery have been reported, such as secondary tumors, cystic changes or cyst formation. But angiomatous lesion and delayed cyst formation after Gamma Knife for intracranial lesion has rarely been reported. Here we report the first case of angiomatous lesion and delayed cyst formation following Gamma Knife for intracranial meningioma and discuss its pathogenesis.

  9. Development of an air knife to remove seed coat fragments during lint cleaning

    USDA-ARS?s Scientific Manuscript database

    An air knife is a tool commonly used to blow off debris in a manufacturing line. The knife may also be used to break the attachment force between a lint cleaner saw and a seed coat fragment (SCF) with attached fiber, and remove them. Work continued on evaluating an auxiliary air knife mounted on t...

  10. Effect of the gamma knife treatment on the trigeminal nerve root in Chinese patients with primary trigeminal neuralgia.

    PubMed

    Song, Zhi-Xiu; Qian, Wei; Wu, Yu-Quan; Sun, Fang-Jie; Fei, Jun; Huang, Run-Sheng; Fang, Jing-Yu; Wu, Cai-Zhen; An, You-Ming; Wang, Daxin; Yang, Jun

    2014-01-01

    To understand the mechanism of the gamma knife treating the trigeminal neuralgia. Using the MASEP-SRRS type gamma knife treatment system, 140 Chinese patients with trigeminal neuralgia (NT) were treated in our hospital from 2002 to 2010, in which the pain relief rate reached 95% and recurrence rate was 3% only. We investigated the effect of the gamma knife treatment on the trigeminal nerve root in 20 Chinese patients with primary trigeminal neuralgia by the magnetic resonance imager (MRI) observation. 1) The cross-sectional area of trigeminal nerve root became smaller and MRI signals were lower in the treatment side than those in the non-treatment side after the gamma knife treatment of primary trigeminal neuralgia; 2) in the treatment side, the cross-sectional area of the trigeminal nerve root decreased significantly after the gamma knife treatment; 3) there was good correlation between the clinical improvement and the MRI findings; and 4) the straight distance between the trigeminal nerve root and the brainstem did not change after the gamma knife treatment. The pain relief induced the gamma knife radiosurgery might be related with the atrophy of the trigeminal nerve root in Chinese patients with primary trigeminal neuralgia.

  11. Municipal waste processing apparatus

    DOEpatents

    Mayberry, John L.

    1989-01-01

    Municipal waste materials are processed by crushing the materials so that pieces of noncombustible material are smaller than a selected size and pieces of combustible material are larger than the selected size. The crushed materials are placed on a vibrating mesh screen conveyor belt having openings which pass the smaller, noncombustible pieces of material, but do not pass the larger, combustible pieces of material. Consecutive conveyors may be connected by an intermediate vibratory plate. An air knife can be used to further separate materials based on weight.

  12. Roll compaction/dry granulation: comparison between roll mill and oscillating granulator in dry granulation.

    PubMed

    Sakwanichol, Jarunee; Puttipipatkhachorn, Satit; Ingenerf, Gernot; Kleinebudde, Peter

    2012-01-01

    Different experimental factorial designs were employed to evaluate granule properties obtained from oscillating granulator and roll mill. Four oscillating-granulator parameters were varied, i.e. rotor speed, oscillating angle, aperture of mesh screen and rotor type. Six roll-mill parameters that were throughput, speed ratio in both first and second stages, gap between roll pair in both stages and roll-surface texture were also investigated. Afterwards, the granule properties obtained from two milling types with similar median particle size were compared. All milling parameters in both milling types affected significantly the median particle size, size distribution and amount of fine particles (P < 0.05), except the rotor types of oscillating granulator on fines. Only three milling parameters influenced significantly the flowability (P < 0.05). These were the throughput and the gap size in the first stage of roll mill and the sieve size of oscillating granulator. In comparison between milling types, the differences of granule properties were not practically relevant. However, the roll mill had much higher capacity than the oscillating granulator about seven times, resulting in improving energy savings per unit of product. Consequently, the roll mill can be applied instead of oscillating granulator for roll compaction/dry granulation technique.

  13. Observation of Phase Objects by Using an X-ray Microscope with a Foucault Knife-Edge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Watanabe, N.; Sasaya, T.; Imai, Y.

    2011-09-09

    An x-ray microscope with a zone plate was assembled at the synchrotron radiation source of BL3C, Photon Factory. A Foucault knife-edge was set at the back focal plate of the objective zone plate and phase retrieval was tested by scanning the knife-edge. A preliminary result shows that scanning the knife-edge during exposure was effective for phase retrieval. Phase-contrast tomography was investigated using differential projection images calculated from two Schlieren images with the oppositely oriented knife-edges. Fairly good reconstruction images of polystyrene beads and spores could be obtained.

  14. Combination of water-jet dissection and needle-knife as a hybrid knife simplifies endoscopic submucosal dissection.

    PubMed

    Lingenfelder, Tobias; Fischer, Klaus; Sold, Moritz G; Post, Stefan; Enderle, Markus D; Kaehler, Georg F B A

    2009-07-01

    The safety and efficacy of endoscopic submucosal dissection (ESD) is very dependent on an effective injection beneath the submucosal lamina and on a controlled cutting technique. After our study group demonstrated the efficacy of the HydroJet in needleless submucosal injections under various physical conditions to create a submucosal fluid cushion (Selective tissue elevation by pressure = STEP technique), the next step was to develop a new instrument to combine the capabilities of an IT-Knife with a high-pressure water-jet in a single instrument. In this experimental study, we compared this new instrument with a standard ESD technique. Twelve gastric ESD were performed in six pigs under endotracheal anesthesia. Square areas measuring 4-cm x 4-cm were marked out on the anterior and posterior wall in the corpus-antrum transition region. The HybridKnife was used as an standard needle knife with insulated tip (i.e., the submucosal injection was performed with an injection needle and only the radiofrequency (RF) part of the HybridKnife was used for cutting (conventional technique)) or the HybridKnife was used in all the individual stages of the ESD, making use of the HybridKnife's combined functions (HybridKnife technique). The size of the resected specimens, the operating time, the frequency with which instruments were changed, the number of bleeding episodes, and the number of injuries to the gastric wall together with the subjective overall assessment of the intervention by the operating physician were recorded. The resected specimens were the same size, with average sizes of 16.96 cm(2) and 15.85 cm(2) resp (p = 0.8125). Bleeding episodes have been less frequent in the HybridKnife group (2.83 vs. 3.5; p = 0.5625). The standard knife caused more injuries to the lamina muscularis propria (0.17 vs. 1.33; p = 0.0313). The operating times had a tendency to be shorter with the HybridKnife technique (47.18 vs. 58.32 minute; p = 0.0313). The combination of a needle-knife with high-pressure water-jet dissection improved the results of endoscopic submucosal dissection in this experimental setting. Because the frequency of complications is still high, further improvements to the instrument are necessary.

  15. Gamma Knife

    MedlinePlus

    ... equipment? How is safety ensured? What is this equipment used for? The Gamma Knife® and its associated ... in size. top of page How does the equipment work? The Gamma Knife® utilizes a technique called ...

  16. Transcatheter arterial chemoembolization (TACE) combined with γ-knife compared to TACE or γ-knife alone for hepatocellular carcinoma.

    PubMed

    Cai, Yeyu; Chang, Qian; Xiao, Enhua; Shang, Quan-Liang; Chen, Zhu

    2018-06-01

    To compare the clinical efficacies and adverse reactions between transcatheter arterial chemoembolization (TACE), γ-ray 3-dimensional fractionated stereotactic conformal radiotherapy (FSCR), and TACE combined with FSCR for primary hepatocellular carcinoma.The study was approved by the Institutional Review Board, and informed consent was waived due to the retrospective study design. About 121 patients met the inclusion criteria and were included in this study, from March 2008 to January 2010, in the Second Xiangya Hospital. Forty-six patients underwent TACE alone, 36 patients underwent γ-knife alone, and 39 were treated by γ-knife combined with TACE. Short-term effects, overall survival rates, adverse reactions, and survival times were compared between the 3 treatment groups.Short-term effects were observed in 41.3% of the TACE group, 33.3% of the γ-knife group, and 64.1% of the TACE combined γ-knife group (P = .020). Overall survival rates at 6,12, 18, and 24 months were 50%, 34.8%, 28.3%, and 21.7% for the TACE group, 36.1%, 30.6%, 16.7%, and 11.1% for γ-knife group, and 84.6%, 71.8%, 61.5%, and 30.8% for TACE combined γ-knife group, respectively. The differences in the overall survival rates at 6, 12, and 18 months between the 3 groups were statistically significant (P = 0), but the overall survival rates at 24 months in the 3 groups were not significantly different (P = .117). The median survival time was 7 months for the TACE group, 3 months for the γ-knife group, and 20 months for the TACE combined γ-knife group (P = 0). There were statistically significant differences (P = .010) of leukopenia between the 3 groups, and no statistically significant differences of (P > .05) thrombocytopenia, anemia, nausea, vomiting, and liver function lesions.TACE combined with γ-knife for primary hepatocellular carcinoma is superior to TACE or γ-knife alone in short-term and long-term effects. This procedure is a mild, safe, and effective treatment for primary hepatocellular carcinoma.

  17. Scissor-type knife significantly improves self-completion rate of colorectal endoscopic submucosal dissection: Single-center prospective randomized trial.

    PubMed

    Yamashina, Takeshi; Takeuchi, Yoji; Nagai, Kengo; Matsuura, Noriko; Ito, Takashi; Fujii, Mototsugu; Hanaoka, Noboru; Higashino, Koji; Uedo, Noriya; Ishihara, Ryu; Iishi, Hiroyasu

    2017-05-01

    Colorectal endoscopic submucosal dissection (C-ESD) is recognized as a difficult procedure. Recently, scissors-type knives were launched to reduce the difficulty of C-ESD. The aim of this study was to evaluate the efficacy and safety of the combined use of a scissors-type knife and a needle-type knife with a water-jet function (WJ needle-knife) for C-ESD compared with using the WJ needle-knife alone. This was a prospective randomized controlled trial in a referral center. Eighty-five patients with superficial colorectal neoplasms were enrolled and randomly assigned to undergo C-ESD using a WJ needle-knife alone (Flush group) or a scissor-type knife-supported WJ needle-knife (SB Jr group). Procedures were conducted by two supervised residents. Primary endpoint was self-completion rate by the residents. Self-completion rate was 67% in the SB Jr group, which was significantly higher than that in the Flush group (39%, P = 0.01). Even after exclusion of four patients in the SB Jr group in whom C-ESD was completed using the WJ needle-knife alone, the self-completion rate was significantly higher (63% vs 39%; P = 0.03). Median procedure time among the self-completion cases did not differ significantly between the two groups (59 vs 51 min; P = 0.14). No fatal adverse events were observed in either group. In this single-center phase II trial, scissor-type knife significantly improved residents' self-completion rate for C-ESD, with no increase in procedure time or adverse events. A multicenter trial would be warranted to confirm the validity of the present study. © 2016 Japan Gastroenterological Endoscopy Society.

  18. Novel design and sensitivity analysis of displacement measurement system utilizing knife edge diffraction for nanopositioning stages.

    PubMed

    Lee, ChaBum; Lee, Sun-Kyu; Tarbutton, Joshua A

    2014-09-01

    This paper presents a novel design and sensitivity analysis of a knife edge-based optical displacement sensor that can be embedded with nanopositioning stages. The measurement system consists of a laser, two knife edge locations, two photodetectors, and axillary optics components in a simple configuration. The knife edge is installed on the stage parallel to its moving direction and two separated laser beams are incident on knife edges. While the stage is in motion, the direct transverse and diffracted light at each knife edge is superposed producing interference at the detector. The interference is measured with two photodetectors in a differential amplification configuration. The performance of the proposed sensor was mathematically modeled, and the effect of the optical and mechanical parameters, wavelength, beam diameter, distances from laser to knife edge to photodetector, and knife edge topography, on sensor outputs was investigated to obtain a novel analytical method to predict linearity and sensitivity. From the model, all parameters except for the beam diameter have a significant influence on measurement range and sensitivity of the proposed sensing system. To validate the model, two types of knife edges with different edge topography were used for the experiment. By utilizing a shorter wavelength, smaller sensor distance and higher edge quality increased measurement sensitivity can be obtained. The model was experimentally validated and the results showed a good agreement with the theoretically estimated results. This sensor is expected to be easily implemented into nanopositioning stage applications at a low cost and mathematical model introduced here can be used for design and performance estimation of the knife edge-based sensor as a tool.

  19. [Infraoccipital needle-knife for cervical vertigo].

    PubMed

    Li, Shaofang; Huang, Manhua; Lin, Zhuopeng; Chen, Xinze; Lin, Dongna; Lu, Peng; Lu, Qu

    2017-03-12

    To observe the clinical effect differences between infraoccipital needle-knife and massage for cervical vertigo. A total of 366 patients with cervical vertigo were randomly assigned into a needle-knife group (186 cases) and a massage group (180 cases). With cases dropping excluded, 183 cases in the needle-knife group and 176 cases in the massage group were included. Needle-knife was used at Fengchi (GB 20), infraoccipital ashi point, etc. in the needle-knife group. The treatment was given for one course, once three days, 5 times as one course. The traditional massage was applied in the massage group for one course, including systematic stroking, kneading, and the application of pressure and plucking, etc., once every two days and 7 times as one course. The dizziness handicap inventory (DHI) score was observed before and after treatment, as well as 3, 6, and 12 months after treatment. The effects were also evaluated. The total effective rate was 92.3% (169/183) in the needle-knife group, which was better than 85.2% (150/176) in the massage group ( P <0.05). Compared with those before treatment, the DHI scores at all the observation time points after treatment were improved in the two groups (all P <0.05), with better improvements after treatment as well as 3 and 6 months after treatment in the needle-knife group (all P <0.05). There was no significant difference in the improvement of DHI scores between the two groups 12 months after treatment ( P >0.05). The recurrence rate was 10.3% (12/117) in the needle-knife group, and it was 10.7% (11/103) in the massage group 12 months after treatment ( P >0.05). Infraoccipital needle-knife achieves apparent effect for cervical vertigo, which is superior to massage in short period.

  20. Development of a nanosuspension for iv administration: From miniscale screening to a freeze dried formulation.

    PubMed

    Frank, Kerstin J; Boeck, Georg

    2016-05-25

    The aim was to develop a nanosuspension of the poorly soluble BI XX. The nanosuspension is intended for intravenous (iv) administration in preclinical studies and should not cause any unwanted side effects. Thus, only stabilizers that are accepted for iv application should be used and isotonicity, euhydria and the absence of living microorganisms were targeted. Suspensions were prepared in a ball-mill (mixing mill MM 400 from Retsch). There were various vials used as containers; HPLC-vials were used for the small scale screening of stabilizers and injection vials for preparation of larger quantities of the nanosuspensions. Particle size distribution was analyzed by laser diffraction measurement (Mastersizer 2000). Lyophilization was used for processing of the suspensions (Christ freeze dryer). Stable nanosuspensions (d90 remained <1μm up to 7days) were prepared with several FDA-accepted stabilizers. Freeze drying was evaluated for one formulation containing 2% of the API, 0.5% of arginine and 4% of mannitol. The particle size distribution before freeze drying and after re-dispersion was comparable. After milling for 2h, no living microorganisms were detected in the nanosuspension. Various FDA accepted excipients were identified which resulted in stable nanosuspensions of BI XX. The most stable formulation was successfully freeze dried. It was proven that milling in the ball-mill decreases the presence of living microorganisms. Copyright © 2016. Published by Elsevier B.V.

  1. A retracting wire knife for cutting fiber bundles and making sheet lesions of brain tissue.

    PubMed

    Shibata, M; Russell, I S

    1979-07-01

    A retracting knife which has two cutting wires for the transection of fiber bundles is described. The knife holds the fiber bundles of the stria terminalis between the two cutting wires and transects them by a shearing movement as the wires close. In addition, the feasability of such a knife producing a sheet lesion around the n. caudatus is also described.

  2. Endoscopic treatment for pancreatic diseases: Needle-knife-guided cannulation via the minor papilla

    PubMed Central

    Wang, Wei; Gong, Biao; Jiang, Wei-Song; Liu, Lei; Bielike, Kouken; Xv, Bin; Wu, Yun-Lin

    2015-01-01

    AIM: To determine the efficacy and safety of meticulous cannulation by needle-knife. METHODS: Three needle-knife procedures were used to facilitate cannulation in cases when standard cannulation techniques failed. A total of 104 cannulations via the minor papilla attempted in 74 patients at our center between January 2008 and June 2014 were retrospectively reviewed. RESULTS: Standard methods were successful in 79 cannulations. Of the 25 cannulations that could not be performed by standard methods, 19 were performed by needle-knife, while 17 (89.5%) were successful. Needle-knife use improved the success rate of cannulation [76.0%, 79/104 vs 92.3%, (79 + 17)/104; P = 0.001]. When the 6 cases not appropriate for needle-knife cannulation were excluded, the success rate was improved further (80.6%, 79/98 vs 98.0%, 96/98; P = 0.000). There were no significant differences in the rates of post-endoscopic retrograde cholangiopancreatography adverse events between the group using standard methods alone and the group using needle-knife after failure of standard methods (4.7% vs 10.5%, P = 0.301). CONCLUSION: The needle-knife procedure may be an alternative method for improving the success rate of cannulation via the minor papilla, particularly when standard cannulation has failed. PMID:26019460

  3. Pleuroscopic punch biopsy using insulated-tip diathermic knife-2 for the diagnosis of desmoplastic malignant mesothelioma.

    PubMed

    Masai, Kyohei; Sasada, Shinji; Izumo, Takehiro; Taniyama, Tomoko; Nakamura, Yukiko; Chavez, Christine; Sakurai, Hiroyuki; Tsuta, Koji; Tsuchida, Takaaki

    2013-10-01

    Desmoplastic malignant mesothelioma (DMM) is a rare subtype of malignant pleural mesothelioma (MPM) and is often difficult to distinguish from pleural fibrosis and reactive mesothelial hyperplasia, especially if the biopsy samples are small. We performed full-thickness pleural biopsy on a lesion suspected to be DMM using an insulated-tip diathermic knife-2 (IT knife-2) during flex-rigid pleuroscopy. IT knife-2 is a novel electrosurgical device for endoscopic submucosal dissection in the early gastrointestinal cancer. It consists of a needle knife with 3 short blades at the distal end attached to an insulated ceramic tip. A 54-year-old man presenting with chest wall mass and thickened pleura, in whom a computed tomography-guided percutaneous needle aspiration had remained negative, underwent flex-rigid pleuroscopy for definitive diagnosis. While applying electric current, we used the IT knife-2 to incise the pleura in a circular shape just above the endothoracic fascia. The incised pleura was removed by forceps and examined pathologically. The microscopic examination was compatible with DMM. We discovered that pleuroscopic punch biopsy using IT knife-2 can diagnose DMM. Use of IT knife-2 during flex-rigid pleuroscopy can obtain sufficient samples from densely thickened pleura, which is difficult to diagnose with small biopsies.

  4. Endoscopic treatment for pancreatic diseases: Needle-knife-guided cannulation via the minor papilla.

    PubMed

    Wang, Wei; Gong, Biao; Jiang, Wei-Song; Liu, Lei; Bielike, Kouken; Xv, Bin; Wu, Yun-Lin

    2015-05-21

    To determine the efficacy and safety of meticulous cannulation by needle-knife. Three needle-knife procedures were used to facilitate cannulation in cases when standard cannulation techniques failed. A total of 104 cannulations via the minor papilla attempted in 74 patients at our center between January 2008 and June 2014 were retrospectively reviewed. Standard methods were successful in 79 cannulations. Of the 25 cannulations that could not be performed by standard methods, 19 were performed by needle-knife, while 17 (89.5%) were successful. Needle-knife use improved the success rate of cannulation [76.0%, 79/104 vs 92.3%, (79 + 17)/104; P = 0.001]. When the 6 cases not appropriate for needle-knife cannulation were excluded, the success rate was improved further (80.6%, 79/98 vs 98.0%, 96/98; P = 0.000). There were no significant differences in the rates of post-endoscopic retrograde cholangiopancreatography adverse events between the group using standard methods alone and the group using needle-knife after failure of standard methods (4.7% vs 10.5%, P = 0.301). The needle-knife procedure may be an alternative method for improving the success rate of cannulation via the minor papilla, particularly when standard cannulation has failed.

  5. Laser schlieren crystal monitor

    NASA Technical Reports Server (NTRS)

    Owen, Robert B. (Inventor); Johnston, Mary H. (Inventor)

    1987-01-01

    A system and method for monitoring the state of a crystal which is suspended in a solution is described which includes providing a light source for emitting a beam of light along an optical axis. A collimating lens is arranged along the optical axis for collimating the emitted beam to provide a first collimated light beam consisting of parallel light rays. By passing the first collimated light beam through a transparent container, a number of the parallel light rays are deflected off the surfaces of said crystal being monitored according to the refractive index gradient to provide a deflected beam of deflected light rays. A focusing lens is arranged along optical axis for focusing the deflected rays towards a desired focal point. A knife edge is arranged in a predetermined orientation at the focal point; and a screen is provided. A portion of the deflected beam is blocked with the knife edge to project only a portion of the deflected beam. A band is created at one edge of the image of the crystal which indicates the state of change of the surface of the crystal being monitored.

  6. A stab in the dark: Design and construction of a novel device for conducting incised knife trauma investigations and its initial test.

    PubMed

    Humphrey, Caitlin; Kumaratilake, Jaliya; Henneberg, Maciej

    2016-05-01

    Knife attacks are commonly seen in Australia and other countries. During forensic investigations the force with which a wound was inflicted is often questioned. The ability to examine resultant trauma and particular weapons at different forces with an experimental device may lead to better interpretations of knife wounds. The objective of this study is to design, construct and test a device to analyse the characteristics and forces involved in knife attacks, particularly incised wounds. The mechanical variables (e.g. force, angle, knife geometry) involved in knife attacks have been considered to design and construct a suitable device which allows these variables to be systematically controlled and varied. A device was designed and constructed from mild steel. This included a pivoting arm and instrumented knife holder. The arm has adjustable angle and weight so that knives can be operated at different calculated forces. A device was successfully constructed and the repeatability of incised knife trauma and its characteristics in skeletal tissues were investigated. A device which allows reproducible and controlled experiments with knife wounds will be advantageous to forensic investigations. In particular, in determining forces and types of weapons associated with particular wounds, identifying or eliminating suspected weapons and more accurately answering the common question: How much force would be required to cause that particular wound. This could help to characterise the perpetrator. The device can be altered to be used in the future to investigate trauma caused by other weapons. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Optimal Shape of a Gamma-ray Collimator: single vs double knife edge

    NASA Astrophysics Data System (ADS)

    Metz, Albert; Hogenbirk, Alfred

    2017-09-01

    Gamma-ray collimators in nuclear waste scanners are used for selecting a narrow vertical segment in activity measurements of waste vessels. The system that is used by NRG uses tapered slit collimators of both the single and double knife edge type. The properties of these collimators were investigated by means of Monte Carlo simulations. We found that single knife edge collimators are highly preferable for a conservative estimate of the activity of the waste vessels. These collimators show much less dependence on the angle of incidence of the radiation than double knife edge collimators. This conclusion also applies to cylindrical collimators of the single knife edge type, that are generally used in medical imaging spectroscopy.

  8. Laparoscopic pyloromyotomy: comparing the arthrotomy knife to the Bovie blade.

    PubMed

    Thomas, Priscilla G; Sharp, Nicole E; St Peter, Shawn D

    2014-07-01

    Laparoscopic pyloromyotomy was performed at our institution using an arthrotomy knife until it became unavailable in 2010. Thus, we adapted the use of the blunt Bovie tip, which can be used with or without electrocautery to perform the myotomy. This study compared the outcomes between using the arthrotomy knife versus the Bovie blade in laparoscopic pyloromyotomies. Retrospective review was performed on all laparoscopic pyloromyotomy patients from October 2007 to September 2012. Arthrotomy knife pyloromyotomy patients were compared with those performed with the Bovie blade. Patient demographics, diagnostic measurements, electrolyte levels, length of stay, operative time, and complications were compared. A total of 381 patients were included, with 191 in the arthrotomy group and 190 in the Bovie blade group. No significant differences existed between groups in age, weight, gender, pyloric dimensions, electrolyte levels, or length of stay. Mean operative times were 15.8±5.6 min with knife and 16.4±5.3 min for Bovie blade (P=0.24). In the arthrotomy knife group, there was one incomplete pyloromyotomy and one omental herniation. There was one wound infection in each group. Readmission rate was greater in the arthrotomy knife group (5.7%) versus the Bovie blade group (3.1%). The Bovie blade appears to offer no objective disadvantages compared with the arthrotomy knife when performing laparoscopic pyloromyotomy. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. [Meta-analysis of needle-knife treatment on cervical spondylosis].

    PubMed

    Kan, Li-Li; Wang, Hai-Dong; Liu, An-Guo

    2013-11-01

    To assess the efficacy of cervical spondylosis by needle-knife treatment according to the correlated literature of RCT,to compare advantages of needle-knife treatment. Randomized Controlled Trials about needle-knife treatment of cervical spondylosis were indexed from Chinese HowNet (CNKI) and Wanfang (WF) from 2000 to 2012, then were analyzed the efficacy by Review Manager 5.1 software. A total of 13 RCT literatures and 1 419 patients were included. The methods of included studies were poor in quality evaluation because of large sample and multi-center RCT studies was lacked, randomization method was not accurate enough, diagnostic criteria and efficacy evaluation were various, only four studies described long-term efficacy, most of the literature didn't describe the adverse event and fall off,all studies did not use the blind method. The Meta analysis outcome showed overall efficiency of needle-knife therapy was better than acupuncture and traction. Needle-knife therapy compared with Acupuncture, the total RR = 0.19, 95% confidence interval was (0.15, 0.24), P < 0.000.01. Compared with traction therapy the total RR = 1.30, 95% confidence intervalwas (1.18,1.42), P < 0.00001. Compared with acupuncture therapy,the overall effectiveness of needle-knife therapy is higher;compared with traction therapy, although,needle-knife therapy has a high overall effectiveness, but because of the loss of total sample size, the outcome RCT researches to confirm.

  10. A quiet harvest: linkage between ritual, seed selection and the historical use of the finger-bladed knife as a traditional plant breeding tool in Ifugao, Philippines.

    PubMed

    Murphy, Kevin M

    2017-01-13

    The transverse harvest knife, also commonly called the finger or finger-bladed knife, has been utilized by rice farmers in southeast Asia for many centuries. The finger knife persisted in many traditional cultures long after the introduction of the sickle, a tool which provided farmers with the means to execute a much faster harvest. Several theories in interpretative archaeology have attempted to account for this rejection of more modern technological innovations. These theories, which include community-based social organization ideas and practical reasons for the continued use of the finger knife, are presented in this paper. Here I suggest an alternate theory based on a re-interpretation of existing research and fusion of existing theories: the primary reason for the historical and continued use of the finger knife is for seed selection through a centuries old tradition of plant breeding. Though I accept the accuracy of the practical and community-based, socio-cultural reasons for the use of the finger knife put forth by other authors, I suggest that seed selection and genetic improvement was the driving factor in the use of the finger knife. Indeed, intricate planting and harvesting rituals, which both ensured and encouraged varietal conservation and improvement co-evolved with the use of the finger knife as the primary harvest tool due to its unique ability to aid the farmer in the art and science of seed selection. When combined with previous ideas, this interpretative theory, based on the connection between ethnoagronomy and material culture, may provide a more complete picture of the story around the persistence of the finger knife in traditional rice-growing cultures in southeast Asia. I focus my theory on the terrace-building Ifugao people in the mountainous Cordillera region of northcentral Philippines; however, to put the use of the finger into a wider regional context, I draw from examples of the use of the finger knife in other traditional cultures throughout the region of southeast Asia.

  11. Ultrasounds pretreatment of olive pomace to improve xylanase and cellulase production by solid-state fermentation.

    PubMed

    Leite, Paulina; Salgado, José Manuel; Venâncio, Armando; Domínguez, José Manuel; Belo, Isabel

    2016-08-01

    Olive mills generate a large amount of waste that can be revaluated. This work aim to improve the production lignocellulolytic enzymes by solid-state fermentation using ultrasounds pretreated olive mill wastes. The composition of olive mill wastes (crude and exhausted olive pomace) was compared and several physicochemical characteristics were significantly different. The use of both wastes in SSF was evaluated and a screening of fungi for xylanase and cellulase production was carried out. After screening, the use of exhausted olive pomace and Aspergillus niger led to the highest enzyme activities, so that they were used in the study of ultrasounds pre-treatment. The results showed that the sonication led to a 3-fold increase of xylanase activity and a decrease of cellulase activity. Moreover, the liquid fraction obtained from ultrasounds treatment was used to adjust the moisture of solid and a positive effect on xylanase (3.6-fold increase) and cellulase (1.2-fold increase) production was obtained. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Experimental study of hybrid-knife endoscopic submucosal dissection (ESD) versus standard ESD in a Western country.

    PubMed

    De-la-Peña, Joaquín; Calderón, Ángel; Esteban, José Miguel; López-Rosés, Leopoldo; Martínez-Ares, David; Nogales, Óscar; Orive-Calzada, Aitor; Rodríguez, Sarbelio; Sánchez-Hernández, Eloy; Vila, Juan; Fernández-Esparrach, Gloria

    2014-02-01

    Endoscopic submucosal dissection (ESD) is an effective but time-consuming treatment for early neoplasia that requires a high level of expertise. The objective of this study was to assess the efficacy and learning curve of gastric ESD with a hybrid knife with high pressure water jet and to compare with standard ESD. We performed a prospective non survival animal study comparing hybrid-knife and standard gastric ESD. Variables recorded were: Number of en-bloc ESD, number of ESD with all marks included (R0), size of specimens, time and speed of dissection and adverse events. Ten endoscopists performed a total of 50 gastric ESD (30 hybrid-knife and 20 standard). Forty-six (92 %) ESD were en-bloc and 25 (50 %) R0 (hybrid-knife: n = 13, 44 %; standard: n = 16, 80 %; p = 0.04). Hybrid-knife ESD was faster than standard (time: 44.6 +/- 21.4 minutes vs. 68.7 +/- 33.5 minutes; p = 0.009 and velocity: 20.8 +/- 9.2 mm(2)/min vs. 14.3 +/- 9.3 mm(2)/min (p = 0.079). Adverse events were not different. There was no change in speed with any of two techniques (hybrid-knife: From 20.33 +/- 15.68 to 28.18 +/- 20.07 mm(2)/min; p = 0.615 and standard: From 6.4 +/- 0.3 to 19.48 +/- 19.21 mm(2)/min; p = 0.607). The learning curve showed a significant improvement in R0 rate in the hybrid-knife group (from 30 % to 100 %). despite the initial performance of hybrid-knife ESD is worse than standard ESD, the learning curve with hybrid knife ESD is short and is associated with a rapid improvement. The introduction of new tools to facilitate ESD should be implemented with caution in order to avoid a negative impact on the results.

  13. [Effect of Small Knife Needle on β-enorpin and Enkehalin Contents of Tansverse Process Syndrome of the Third Vertebra].

    PubMed

    Liu, Nai-gang; Guo, Chang-qing; Sun, Hong-mei; Li, Xiao-hong; Wu, Hai-xia; Xu, Hong

    2016-04-01

    To explore the analgesic mechanism of small knife needle for treating transverse process syndrome of the third vertebra (TPSTV) by observing peripheral and central changesof β-endorphin (β-EP) and enkephalin (ENK) contents. Totally 30 Japanese white big-ear rabbits of clean grade were divided into 5 groups according to random digit table, i.e., the normal control group, the model group, the small knife needle group, the electroacupunture (EA) group, and the small knife needle plus EA group, 6 in each group. The TPSTV model was established by inserting a piece of gelatin sponge into the left transverse process of 3rd lumbar vertebrae. Rabbits in the small knife needlegroup were intervened by small knife needle. Those in the EA group were intervened by EA at bilateralWeizhong (BL40). Those in the small knife needle plus EA group were intervened by small knife needleand EA at bilateral Weizhong (BL40). Contents of β-EP and ENK in plasma, muscle, spinal cord, and hypothalamus were determined after sample collection at day 28 after modeling. Compared with the normal control group, contents of β-EP and ENK in plasma and muscle increased significantly, and contents of β-EP and ENK in spinal cord and hypothalamus decreased significantly in the model group (P < 0.05, P < 0.01). Contents of β-EP and ENK approximated normal levels in the three treatment groups after respective treatment. Compared with the model group, the content of β-EP in muscle decreased, and contents of β-EP and ENK in hypothalamus increased in the three treatment groups after respective treatment (P < 0.05). There were no significant difference among the three treatment groups (P > 0.05). Small knife needle treatment and EA had benign regulation on peripheral and central β-EP and ENK in TPSTV rabbits. Small knife needle treatment showed better effect than that of EA.

  14. Current gamma knife treatment for ophthalmic branch of primary trigeminal neuralgia

    PubMed Central

    Shan, Guo-Yong; Liang, Hao-Fang; Zhang, Jian-Hua

    2011-01-01

    AIM To probe into problems existing in gamma knife treatment of ophthalmic branch of primary trigeminal neuralgia (TN), and propose a safe and effective solution to the problem. METHODS Through sorting the literature reporting gamma knife treatment of refractory TN in recent years, this article analyzed the advantages and problems of gamma knife treatment of primary TN, and proposed reasonable assessment for existing problems and the possible solution. RESULTS Gamma knife treatment of TN has drawn increasing attention of clinicians due to its unique non-invasion, safety and effectiveness, but there are three related issues to be considered. The first one is the uncertainty of the optimal dose (70-90GY); the second one is the difference in radiotherapy target selection (using a single isocenter or two isocenters); and the third one is the big difference of recurrent pains (specific treatment methods need to be summarized and improved). CONCLUSION For patients with refractory TN, gamma knife treatment can be selected when the medical treatment fails or drug side effects emerge. The analysis of a large number of TN patients receiving gamma knife treatment has shown that this is a safe and effective treatment method. PMID:22553625

  15. Outcome of peroral endoscopic myotomy in achalasia cardia: Experience with a new triangular knife.

    PubMed

    Nabi, Zaheer; Ramchandani, Mohan; Chavan, Radhika; Kalapala, Rakesh; Darisetty, Santosh; Reddy, D Nageshwar

    2018-01-01

    Peroral endoscopic myotomy (POEM) is a technically demanding procedure. Recently, a new triangular knife with integrated water jet function (TTJ) has been introduced. The present study was aimed to analyze and compare the operating time, efficacy, and adverse events (AEs) between the conventional (TT knife) and new knife (TTJ). All patients with achalasia cardia (AC) who underwent POEM between August 2015 and November 2016 were analyzed retrospectively. Operating time (OT), technical success, and AEs were assessed and compared between TT and TTJ knife. A total of 193 patients with AC underwent POEM during the specified period. Both groups had equivalent number of different subtypes of AC (I, II, and III). There was no difference in technical success between the two groups (TT, 99% vs TT, 98.9%). OT was significantly less in the TTJ group as compared to TT group (53.8 ± 15.2 vs 66.26 ± 19.2; P = 0.0001). On subanalysis, OT taken for submucosal tunneling was significantly less with TTJ knife (34.6 ± 10.1 vs 45.83 ± 14.80), whereas OT was similar for myotomy and clipping in both the groups. Significantly fewer use of coagulation forceps and exchanges of accessories were required in TTJ knife group (2.92 ± 1.77 vs 10.5 ± 3.58; P = 0.0001). There were no major AEs. Minor AEs were noted in 21.5% and 31% of patients in TTJ and TT knife groups, respectively. New triangular knife reduces procedure time and technical difficulty with POEM. POEM is an efficacious treatment for achalasia and can be safely executed in an endoscopy unit.

  16. Outcome of peroral endoscopic myotomy in achalasia cardia: Experience with a new triangular knife

    PubMed Central

    Nabi, Zaheer; Ramchandani, Mohan; Chavan, Radhika; Kalapala, Rakesh; Darisetty, Santosh; Reddy, D. Nageshwar

    2018-01-01

    Background and Aim: Peroral endoscopic myotomy (POEM) is a technically demanding procedure. Recently, a new triangular knife with integrated water jet function (TTJ) has been introduced. The present study was aimed to analyze and compare the operating time, efficacy, and adverse events (AEs) between the conventional (TT knife) and new knife (TTJ). Patients and Methods: All patients with achalasia cardia (AC) who underwent POEM between August 2015 and November 2016 were analyzed retrospectively. Operating time (OT), technical success, and AEs were assessed and compared between TT and TTJ knife. Results: A total of 193 patients with AC underwent POEM during the specified period. Both groups had equivalent number of different subtypes of AC (I, II, and III). There was no difference in technical success between the two groups (TT, 99% vs TT, 98.9%). OT was significantly less in the TTJ group as compared to TT group (53.8 ± 15.2 vs 66.26 ± 19.2; P = 0.0001). On subanalysis, OT taken for submucosal tunneling was significantly less with TTJ knife (34.6 ± 10.1 vs 45.83 ± 14.80), whereas OT was similar for myotomy and clipping in both the groups. Significantly fewer use of coagulation forceps and exchanges of accessories were required in TTJ knife group (2.92 ± 1.77 vs 10.5 ± 3.58; P = 0.0001). There were no major AEs. Minor AEs were noted in 21.5% and 31% of patients in TTJ and TT knife groups, respectively. Conclusion: New triangular knife reduces procedure time and technical difficulty with POEM. POEM is an efficacious treatment for achalasia and can be safely executed in an endoscopy unit. PMID:29451180

  17. The Stanford Automated Mounter: Pushing the limits of sample exchange at the SSRL macromolecular crystallography beamlines

    DOE PAGES

    Russi, Silvia; Song, Jinhu; McPhillips, Scott E.; ...

    2016-02-24

    The Stanford Automated Mounter System, a system for mounting and dismounting cryo-cooled crystals, has been upgraded to increase the throughput of samples on the macromolecular crystallography beamlines at the Stanford Synchrotron Radiation Lightsource. This upgrade speeds up robot maneuvers, reduces the heating/drying cycles, pre-fetches samples and adds an air-knife to remove frost from the gripper arms. As a result, sample pin exchange during automated crystal quality screening now takes about 25 s, five times faster than before this upgrade.

  18. The Stanford Automated Mounter: Pushing the limits of sample exchange at the SSRL macromolecular crystallography beamlines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Russi, Silvia; Song, Jinhu; McPhillips, Scott E.

    The Stanford Automated Mounter System, a system for mounting and dismounting cryo-cooled crystals, has been upgraded to increase the throughput of samples on the macromolecular crystallography beamlines at the Stanford Synchrotron Radiation Lightsource. This upgrade speeds up robot maneuvers, reduces the heating/drying cycles, pre-fetches samples and adds an air-knife to remove frost from the gripper arms. As a result, sample pin exchange during automated crystal quality screening now takes about 25 s, five times faster than before this upgrade.

  19. Surface measuring technique. [using a laser to scan the surface of a reflector

    NASA Technical Reports Server (NTRS)

    Spiers, R. B., Jr.

    1980-01-01

    Measurement of the surface contour of a large electrostatically formed concave reflector using a modified Foucault or knife edge test is described. The curve of the actual electrostatically formed reflector surface is compared to a curve representing a reference sphere. Measurements of surface slope and deviation are calculated every 15 cm along the reflector's horizontal and vertical diameters. Characterization of surface roughness on a small scale compared to the laser spot size at the reflector are obtained from the increased laser spot size at a distant projection screen.

  20. 21 CFR 874.4420 - Ear, nose, and throat manual surgical instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... device includes the esophageal dilator; tracheal bistour (a long, narrow surgical knife); tracheal dilator; tracheal hook; laryngeal injection set; laryngeal knife; laryngeal saw; laryngeal trocar...; wire ear loop; microrule; mirror; mobilizer; ear, nose, and throat punch; ear, nose and throat knife...

  1. Management of Liver Cancer Argon-helium Knife Therapy with Functional Computer Tomography Perfusion Imaging.

    PubMed

    Wang, Hongbo; Shu, Shengjie; Li, Jinping; Jiang, Huijie

    2016-02-01

    The objective of this study was to observe the change in blood perfusion of liver cancer following argon-helium knife treatment with functional computer tomography perfusion imaging. Twenty-seven patients with primary liver cancer treated with argon-helium knife and were included in this study. Plain computer tomography (CT) and computer tomography perfusion (CTP) imaging were conducted in all patients before and after treatment. Perfusion parameters including blood flows, blood volume, hepatic artery perfusion fraction, hepatic artery perfusion, and hepatic portal venous perfusion were used for evaluating therapeutic effect. All parameters in liver cancer were significantly decreased after argon-helium knife treatment (p < 0.05 to all). Significant decrease in hepatic artery perfusion was also observed in pericancerous liver tissue, but other parameters kept constant. CT perfusion imaging is able to detect decrease in blood perfusion of liver cancer post-argon-helium knife therapy. Therefore, CTP imaging would play an important role for liver cancer management followed argon-helium knife therapy. © The Author(s) 2014.

  2. NEEDLE KNIFE SPHINCTEROTOMY - THE CHRIS HANI BARAGWANATH ACADEMIC HOSPITAL EXPERIENCE.

    PubMed

    Thomson, J T; Smith, M D; Omoshoro-Jones, J A O; Devar, J D; Khan, Z K; Jugmohan, B J

    2017-06-01

    Deep biliary cannulation is essential in performing a therapeutic ERCP. Cannulation can be enhanced through the utilization of a pre-cut by means of a needle knife sphincterotomy. Retrospective analysis of the Chris Hani Baragwanath Academic Hospital's ERCP database was performed. All ERCPs performed with the aid of a needle knife were identified and analysed for successful and unsuccessful deep biliary cannulation. 2830 ERCPs were performed during the study period. 369 (13%) required needle knife sphincterotomies and successful deep biliary cannulation was achieved in 229 (62%) of these patients. Repeat ERCPs were performed on 125 (34%) patients. 61 (49%) of the repeat ERCPs were performed because of previously failed cannulation. 34 (56%) of these repeat ERCPs resulted in successful deep biliary cannulation at re-attempt. 99% of successful cannulations at repeat ERCP had had a needle knife sphincterotomy at the first ERCP. Needle knife sphincterotomy improves deep biliary cannulation at initial ERCP and subsequent ERCPs with low incidences of complications.

  3. Dual laser optical system and method for studying fluid flow

    NASA Technical Reports Server (NTRS)

    Owen, R. B.; Witherow, W. K. (Inventor)

    1983-01-01

    A dual laser optical system and method is disclosed for visualization of phenomena in transport substances which induce refractive index gradients such as fluid flow and pressure and temperature gradients in fluids and gases. Two images representing mutually perpendicular components of refractive index gradients may be viewed simultaneously on screen. Two lasers having wave lengths in the visible range but separated by about 1000 angstroms are utilized to provide beams which are collimated into a beam containing components of the different wave lengths. The collimated beam is passed through a test volume of the transparent substance. The collimated beam is then separated into components of the different wave lengths and focused onto a pair of knife edges arranged mutually perpendicular to produce and project images onto the screen.

  4. The Knife Machine. Module 15.

    ERIC Educational Resources Information Center

    South Carolina State Dept. of Education, Columbia. Office of Vocational Education.

    This module on the knife machine, one in a series dealing with industrial sewing machines, their attachments, and operation, covers one topic: performing special operations on the knife machine (a single needle or multi-needle machine which sews and cuts at the same time). These components are provided: an introduction, directions, an objective,…

  5. The Shoemaker's Knife

    ERIC Educational Resources Information Center

    Thomson, Ian

    2010-01-01

    Archimedes, the famous Greek mathematician, lived from 287 BCE until approximately 212 BCE. He thought that the figure of two semi-circles on a straight line enclosed by a larger semi-circle resembled a shoemaker's knife. Archimedes called this figure an "arbelos" since arbelos is the Greek word for a shoemaker's knife. The author describes the…

  6. Treatment of epidermoid tumors with gamma knife radiosurgery: Case series.

    PubMed

    Vasquez, Javier A Jacobo; Fonnegra, Julio R; Diez, Juan C; Fonnegra, Andres

    2016-01-01

    Epidermoid tumors (ETs) are benign lesions that are treated mainly by means of surgical resection, with overall good results. External beam radiotherapy is an alternative treatment for those recurrent tumors, in which a second surgery might not be the best choice for the patient. A little information exists about the effectiveness of gamma knife radiosurgery for the treatment of newly diagnosed and recurrent ETs. We present three cases of ETs treated with gamma knife radiosurgery. Case 1 is a 21-year-old female with an ET located in the left cerebellopontine angle (CPA) with symptoms related to VIII cranial nerve dysfunction. Symptom control was achieved and maintained after single session radiosurgery with gamma knife. Case 2 is a 59-year-old female patient with the history of trigeminal neuralgia secondary to a recurrent ET located in the left CPA. Significant pain improvement was achieved after treatment with gamma knife radiosurgery. Case 3 is a 29-year-old male patient with a CPA ET causing long lasting trigeminal neuralgia, pain relief was achieved in this patient after gamma knife radiosurgery. Long-term symptom relief was achieved in all three cases proving that gamma knife radiosurgery is a good and safe alternative for patients with recurrent or nonsurgically treated ETs.

  7. Endoscopic submucosal dissection for superficial esophageal neoplasms using the stag beetle knife.

    PubMed

    Fujinami, H; Hosokawa, A; Ogawa, K; Nishikawa, J; Kajiura, S; Ando, T; Ueda, A; Yoshita, H; Sugiyama, T

    2014-01-01

    Endoscopic submucosal dissection (ESD) is an accepted standard treatment for early gastric cancer but is not widely used in the esophagus because of technical difficulties. To increase the safety of esophageal ESD, we used a scissors-type device called the stag beetle (SB) knife. The aim of this study was to determine the efficacy and safety of ESD using the SB knife. We performed a single-center retrospective, uncontrolled trial. A total of 38 lesions were excised by ESD from 35 consecutive patients who were retrospectively divided into the following two groups according to the type of knife used to perform ESD: the hook knife (hook group) was used in 20 patients (21 lesions), and the SB knife (SB group) was used in 15 patients (17 lesions). We evaluated and compared the operative time, lesion size, en bloc resection rate, pathological margins free rate, and complication rate in both groups. The operative time was shorter in the SB group (median 70.0 minutes [interquartile range, 47.5-87.0]) than in the hook group (92.0 minutes [interquartile range, 63.0-114.0]) (P = 0.019), and the rate of complications in the SB group was 0% compared with 45.0% in the hook group (P = 0.004). However, the lesion size, en bloc resection rate, and pathological margins free rate did not differ significantly between the two groups. In conclusion, ESD using the SB knife was safer than that using a conventional knife for superficial esophageal neoplasms. © 2013 Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.

  8. Knife inflicted penetrating injuries of the maxillofacial region: a descriptive, record-based study.

    PubMed

    Meer, M; Siddiqi, A; Morkel, J A; Janse van Rensburg, P; Zafar, S

    2010-01-01

    Penetrating knife injuries of the face are more common in South Africa than the rest of the world. These injuries can be life-threatening, especially where the major blood vessels of the face are involved. The approach to treatment should be multidisciplinary, beginning with the trauma unit to provide airway maintenance and haemodynamic stabilisation. An interventional radiologist may be consulted for angiography. The aim of the present study was to retrospectively analyse all cases of knife-inflicted penetrating injuries to the maxillofacial region with the knife in situ and subsequently develop a management protocol to be used by maxillofacial surgery registrars when presented with such cases. It was a retrospective, cross-sectional and record-based study, analysing all penetrating knife injuries reported at various hospitals for a period of 11 years. In this study, 24 cases of knife injuries were analysed. Twenty-one patients (87.5%) in this series were male and three (12.5%) were female. Of these 24 patients, 13 (54.2%) were coloured and 11 (45.8%) were black. There were no white or Indian patients. Post-surgical recovery of all patients was rapid and uneventful, and there were no fatalities. Patients with knife injuries to the face with no definite signs of vascular injury can thus be safely and accurately managed on the basis of physical examination and plain-film radiography. An angiogram is mandatory if the patient presents with excessive bleeding, an expanding haematoma or if the knife blade is in the region of any large vessels.

  9. Sedimentation and sediment chemistry, Neopit Mill Pond, Menominee Indian Reservation, Wisconsin, 2001

    USGS Publications Warehouse

    Fitzpatrick, Faith A.; Peppler, Marie C.

    2003-01-01

    The volume, texture, and chemistry of sediment deposited in a mill pond on the West Branch of the Wolf River at Neopit, Wis., Menominee Reservation, were studied in 2001-2002. The study was accomplished by examining General Land Office Survey Notes from 1854, establishing 12 transects through the mill pond, conducting soundings of the soft and hard bottom along each transect, and collecting core samples for preliminary screening of potential contaminants. Combined information from transects, cores, and General Land Office Survey notes were used to reconstruct the pre-dam location of the West Branch of the Wolf River through the mill pond. Neopit Mill Pond contains approximately 253 acre-ft of organic-rich muck, on average about 1.2 ft thick, that was deposited after the dam was built. Elevated concentrations of polycyclic aromatic hydrocarbons (PAHs) associated with creosote and pentachlorophenol were found in post-dam sediment samples collected from Neopit Mill Pond. Trace-element concentrations were at or near background concentrations. Further study and sampling are needed to identify the spatial extent and variability of the PAHs, pentachlorophenol, and other byproducts from wood preservatives

  10. Machinability Study on Milling Kenaf Fiber Reinforced Plastic Composite Materials using Design of Experiments

    NASA Astrophysics Data System (ADS)

    Azmi, H.; Haron, C. H. C.; Ghani, J. A.; Suhaily, M.; Yuzairi, A. R.

    2018-04-01

    The surface roughness (Ra) and delamination factor (Fd) of a milled kenaf reinforced plastic composite materials are depending on the milling parameters (spindle speed, feed rate and depth of cut). Therefore, a study was carried out to investigate the relationship between the milling parameters and their effects on a kenaf reinforced plastic composite materials. The composite panels were fabricated using vacuum assisted resin transfer moulding (VARTM) method. A full factorial design of experiments was use as an initial step to screen the significance of the parameters on the defects using Analysis of Variance (ANOVA). If the curvature of the collected data shows significant, Response Surface Methodology (RSM) is then applied for obtaining a quadratic modelling equation that has more reliable in expressing the optimization. Thus, the objective of this research is obtaining an optimum setting of milling parameters and modelling equations to minimize the surface roughness (Ra) and delamination factor (Fd) of milled kenaf reinforced plastic composite materials. The spindle speed and feed rate contributed the most in affecting the surface roughness and the delamination factor of the kenaf composite materials.

  11. Using the phacoemulsification crescent knife in dacryocystorhinostomy.

    PubMed

    Fong, K S; Koh, A H; Choo, C T

    1998-04-01

    Dacryocystorhinostomy is an effective treatment for nasolacrimal duct obstruction. Most techniques employ a conventional blade or knife in making the incision of the nasal mucosa and lacrimal sac. The authors describe the use of a phacoemulsification crescent knife for this purpose. This technique can be effective and at the same time safer and easier to perform.

  12. Clinical outcomes of gamma knife radiosurgery in the salvage treatment of patients with recurrent high-grade glioma.

    PubMed

    Elaimy, Ameer L; Mackay, Alexander R; Lamoreaux, Wayne T; Demakas, John J; Fairbanks, Robert K; Cooke, Barton S; Lamm, Andrew F; Lee, Christopher M

    2013-12-01

    Previously published randomized evidence did not report a survival advantage for patients diagnosed with grade IV glioma who were treated with stereotactic radiosurgery followed by external beam radiation therapy and chemotherapy when compared to patients treated with external beam radiation therapy and chemotherapy alone. In recent years, gamma knife radiosurgery has become increasingly popular as a salvage treatment modality for patients diagnosed with recurrent high-grade glioma. The purpose of this article is to review the efficacy of gamma knife radiosurgery for patients who suffer from this malignancy. Retrospective, prospective, and randomized clinical studies published between the years 2000 and 2012 analyzing gamma knife radiosurgery for patients with high-grade glioma were reviewed. After assessing patient age, Karnofsky performance status, tumor histology, and extent of resection, gamma knife radiosurgery is a viable, minimally invasive treatment option for patients diagnosed with recurrent high-grade glioma. The available prospective and retrospective evidence suggests that gamma knife radiosurgery provides patients with a high local tumor control rate and a median survival after tumor recurrence ranging from 13 to 26 months. Gamma knife radiosurgery followed by chemotherapy for recurrent high-grade glioma may provide select patients with increased levels of survival. However, further investigation into this matter is needed due to the limited number of published reports. Additional clinical research is also needed to analyze the efficacy and radiation-related toxicities of fractionated gamma knife radiosurgery due to its potential to limit treatment-associated morbidity. Gamma knife radiosurgery is a safe and effective treatment option for select patients diagnosed with recurrent high-grade glioma. Although treatment outcomes have improved, further evidence in the form of phase III randomized trials is needed to assess the durability of treating patients in specific clinical situations. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Failure modes and effects analysis (FMEA) for Gamma Knife radiosurgery.

    PubMed

    Xu, Andy Yuanguang; Bhatnagar, Jagdish; Bednarz, Greg; Flickinger, John; Arai, Yoshio; Vacsulka, Jonet; Feng, Wenzheng; Monaco, Edward; Niranjan, Ajay; Lunsford, L Dade; Huq, M Saiful

    2017-11-01

    Gamma Knife radiosurgery is a highly precise and accurate treatment technique for treating brain diseases with low risk of serious error that nevertheless could potentially be reduced. We applied the AAPM Task Group 100 recommended failure modes and effects analysis (FMEA) tool to develop a risk-based quality management program for Gamma Knife radiosurgery. A team consisting of medical physicists, radiation oncologists, neurosurgeons, radiation safety officers, nurses, operating room technologists, and schedulers at our institution and an external physicist expert on Gamma Knife was formed for the FMEA study. A process tree and a failure mode table were created for the Gamma Knife radiosurgery procedures using the Leksell Gamma Knife Perfexion and 4C units. Three scores for the probability of occurrence (O), the severity (S), and the probability of no detection for failure mode (D) were assigned to each failure mode by 8 professionals on a scale from 1 to 10. An overall risk priority number (RPN) for each failure mode was then calculated from the averaged O, S, and D scores. The coefficient of variation for each O, S, or D score was also calculated. The failure modes identified were prioritized in terms of both the RPN scores and the severity scores. The established process tree for Gamma Knife radiosurgery consists of 10 subprocesses and 53 steps, including a subprocess for frame placement and 11 steps that are directly related to the frame-based nature of the Gamma Knife radiosurgery. Out of the 86 failure modes identified, 40 Gamma Knife specific failure modes were caused by the potential for inappropriate use of the radiosurgery head frame, the imaging fiducial boxes, the Gamma Knife helmets and plugs, the skull definition tools as well as other features of the GammaPlan treatment planning system. The other 46 failure modes are associated with the registration, imaging, image transfer, contouring processes that are common for all external beam radiation therapy techniques. The failure modes with the highest hazard scores are related to imperfect frame adaptor attachment, bad fiducial box assembly, unsecured plugs/inserts, overlooked target areas, and undetected machine mechanical failure during the morning QA process. The implementation of the FMEA approach for Gamma Knife radiosurgery enabled deeper understanding of the overall process among all professionals involved in the care of the patient and helped identify potential weaknesses in the overall process. The results of the present study give us a basis for the development of a risk based quality management program for Gamma Knife radiosurgery. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  14. Long-Term Results of Gamma Knife Radiosurgery for Intracranial Meningioma.

    PubMed

    Jang, Chang Ki; Jung, Hyun Ho; Chang, Jong Hee; Chang, Jin Woo; Park, Yong Gou; Chang, Won Seok

    2015-10-01

    The predominant treatment modality for meningioma is surgical resection. However, gamma knife radiosurgery is also an important treatment modality for meningioma that is small or cannot be completely removed because of its location. In this study, we evaluated the effectiveness and long-term results of radiosurgical treatment for meningioma in our institution. We studied 628 patients (130 men and 498 women) who underwent gamma knife radiosurgery for intracranial meningioma, which is radiologically diagnosed, from Jan 2008 to Nov 2012. We included patients with single lesion meningioma, and followed up after 6 months with imaging, and then at 24 months with a clinical examination. Patients with high-grade meningioma or multiple meningiomas were excluded. We analyzed each of the factors associated with progression free survival. The median patient's age was 56.8 years. Maximal dosage was 27.8 Gy and marginal dosage was 13.9 Gy. The overall tumor control rate was 95%. Twenty-eight patients (4.4%) showed evidence of tumor recurrence. Ninety-eight patients (15%) developed peritumoral edema (PTE) after gamma-knife surgery; two of them (2%) underwent surgical resections due to PTE. Nine patients had craniotomy and tumor removal after gamma knife surgery. Gamma knife surgery for intracranial meningioma has proven to be a safe and effective treatment tool with successful long-term outcomes. Gamma knife radiosurgery can be especially effective in cases of remnant meningioma after surgical resection or where PTE is not present.

  15. How sharp is sharp? Towards quantification of the sharpness and penetration ability of kitchen knives used in stabbings.

    PubMed

    Hainsworth, S V; Delaney, R J; Rutty, G N

    2008-07-01

    Stabbing is the most common method for violent death in the UK. As part of their investigation, forensic pathologists are commonly asked to estimate or quantify the degree of force required to create a wound. The force required to penetrate the skin and body by a knife is a complex function of the sharpness of the knife, the area of the body and alignment with cleavage lines of the skin, the angle of attack and the relative movement of the person stabbing relative to the victim being stabbed. This makes it difficult for the forensic pathologist to give an objective answer to the question; hence, subjective estimations are often used. One area where some degree of quantification is more tractable is in assessing how sharp an implement (particularly a knife) is. This paper presents results of a systematic study of how the different aspects of knife geometry influence sharpness and presents a simple test for assessing knife sharpness using drop testing. The results show that the radius of the blunt edge at the tip is important for controlling the penetration ability of a kitchen knife. Using high-speed video, it also gives insight into the mechanism of knife penetration into the skin. The results of the study will aid pathologists in giving a more informed answer to the question of the degree of force used in stabbing.

  16. Knife River Indian Villages National Historic Site: Teacher's Guide.

    ERIC Educational Resources Information Center

    National Park Service (Dept. of Interior), Washington, DC. National Register of Historic Places.

    This guide provides history and social studies teachers, at all grade levels, with information and activities about the American Indians of the Northern Plains who lived in the area of the Knife River where it enters the Missouri River. Located in what is now North Dakota, this area is the Knife River Indian Villages National Historic Site. The…

  17. "Knife to skin" time is a poor marker of operating room utilization and efficiency in cardiac surgery.

    PubMed

    Luthra, Suvitesh; Ramady, Omar; Monge, Mary; Fitzsimons, Michael G; Kaleta, Terry R; Sundt, Thoralf M

    2015-06-01

    Markers of operation room (OR) efficiency in cardiac surgery are focused on "knife to skin" and "start time tardiness." These do not evaluate the middle and later parts of the cardiac surgical pathway. The purpose of this analysis was to evaluate knife to skin time as an efficiency marker in cardiac surgery. We looked at knife to skin time, procedure time, and transfer times in the cardiac operational pathway for their correlation with predefined indices of operational efficiency (Index of Operation Efficiency - InOE, Surgical Index of Operational Efficiency - sInOE). A regression analysis was performed to test the goodness of fit of the regression curves estimated for InOE relative to the times on the operational pathway. The mean knife to skin time was 90.6 ± 13 minutes (23% of total OR time). The mean procedure time was 282 ± 123 minutes (71% of total OR time). Utilization efficiencies were highest for aortic valve replacement and coronary artery bypass grafting and least for complex aortic procedures. There were no significant procedure-specific or team-specific differences for standard procedures. Procedure times correlated the strongest with InOE (r = -0.98, p < 0.01). Compared to procedure times, knife to skin is not as strong an indicator of efficiency. A statistically significant linear dependence on InOE was observed with "procedure times" only. Procedure times are a better marker of OR efficiency than knife to skin in cardiac cases. Strategies to increase OR utilization and efficiency should address procedure times in addition to knife to skin times. © 2015 Wiley Periodicals, Inc.

  18. Diamond knife-assisted deep anterior lamellar keratoplasty to manage keratoconus.

    PubMed

    Vajpayee, Rasik B; Maharana, Prafulla K; Sharma, Namrata; Agarwal, Tushar; Jhanji, Vishal

    2014-02-01

    To evaluate the outcomes of a new surgical technique, diamond knife-assisted deep anterior lamellar keratoplasty (DALK), and compare its visual and refractive results with big-bubble DALK in cases of keratoconus. Tertiary eyecare hospital. Comparative case series. The visual and surgical outcomes of diamond knife-assisted DALK were compared with those of successful big-bubble DALK. Diamond knife-assisted DALK was performed in 19 eyes and big-bubble DALK, in 11 eyes. All surgeries were completed successfully. No intraoperative or postoperative complications occurred with diamond knife-assisted DALK. Six months after diamond knife-assisted DALK, the mean corrected distance visual acuity (CDVA) improved significantly from 1.87 logMAR ± 0.22 (SD) to 0.23 ± 0.06 logMAR, the mean keratometry improved from 65.99 ± 8.86 diopters (D) to 45.13 ± 1.16 D, and the mean keratometric cylinder improved from 7.99 ± 3.81 D to 2.87 ± 0.59 D (all P=.005). Postoperatively, the mean refractive astigmatism was 2.55 ± 0.49 D and the mean spherical equivalent was -1.97 ± 0.56 D. The mean logMAR CDVA (P = .06), postoperative keratometry (P=.64), refractive cylinder (P=.63), and endothelial cell loss (P=.11) were comparable between diamond knife-assisted DALK and big-bubble DALK. Diamond knife-assisted DALK was effective and predictable as a surgical technique for management of keratoconus cases. This technique has the potential to offer visual and refractive outcomes comparable to those of big-bubble DALK. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Bipolar plasma vaporization using plasma-cutting and plasma-loop electrodes versus cold-knife transurethral incision for the treatment of posterior urethral stricture: a prospective, randomized study.

    PubMed

    Cai, Wansong; Chen, Zhiyuan; Wen, Liping; Jiang, Xiangxin; Liu, Xiuheng

    2016-01-01

    Evaluate the efficiency and safety of bipolar plasma vaporization using plasma-cutting and plasma-loop electrodes for the treatment of posterior urethral stricture. Compare the outcomes following bipolar plasma vaporization with conventional cold-knife urethrotomy. A randomized trial was performed to compare patient outcomes from the bipolar and cold-knife groups. All patients were assessed at 6 and 12 months postoperatively via urethrography and uroflowmetry. At the end of the first postoperative year, ureteroscopy was performed to evaluate the efficacy of the procedure. The mean follow-up time was 13.9 months (range: 12 to 21 months). If re-stenosis was not identified by both urethrography and ureteroscopy, the procedure was considered "successful". Fifty-three male patients with posterior urethral strictures were selected and randomly divided into two groups: bipolar group (n=27) or cold-knife group (n=26). Patients in the bipolar group experienced a shorter operative time compared to the cold-knife group (23.45±7.64 hours vs 33.45±5.45 hours, respectively). The 12-month postoperative Qmax was faster in the bipolar group than in the cold-knife group (15.54±2.78 ml/sec vs 18.25±2.12 ml/sec, respectively). In the bipolar group, the recurrence-free rate was 81.5% at a mean follow-up time of 13.9 months. In the cold-knife group, the recurrence-free rate was 53.8%. The application of bipolar plasma-cutting and plasma-loop electrodes for the management of urethral stricture disease is a safe and reliable method that minimizes the morbidity of urethral stricture resection. The advantages include a lower recurrence rate and shorter operative time compared to the cold-knife technique.

  20. Influence on grip of knife handle surface characteristics and wearing protective gloves.

    PubMed

    Claudon, Laurent

    2006-11-01

    Ten subjects were asked to apply maximum torques on knife handles with either their bare hand or their hand wearing a Kevlar fibre protective glove. Four knife handles (2 roughnesses, 2 hardnesses) were tested. Surface electromyograms of 6 upper limb and shoulder muscles were recorded and subject opinions on both knife handle hardness and friction in the hand were also assessed. The results revealed the significant influence of wearing gloves (p<0.0001), knife type (p<0.0005) and handle hardness (p<0.005) on the applied torque. Wearing Kevlar fibre gloves greatly increased the torque independently of the other two parameters. Under the bare hand condition, a 90 degrees ShA slightly rough handle provided the greatest torque. Subject opinion agreed with the observed effects on recorded torque values except for the hardness factor, for which a preference for the 70 degrees ShA value over the 90 degrees ShA value emerged.

  1. Cheating Goes Global as Essay Mills Multiply

    ERIC Educational Resources Information Center

    Bartlett, Thomas

    2009-01-01

    The orders keep piling up. A philosophy student needs a paper on Martin Heidegger. A nursing student needs a paper on dying with dignity. An engineering student needs a paper on electric cars. Screen after screen, assignment after assignment--hundreds at a time, thousands each semester. The students come from all disciplines and all parts of the…

  2. Objective assessment of knife sharpness over a working day cutting meat.

    PubMed

    Savescu, Adriana; Cuny-Guerrier, Aude; Wild, Pascal; Reno, Gilles; Aublet-Cuvelier, Agnès; Claudon, Laurent

    2018-04-01

    Knife sharpness is one of multiple factors involved in musculoskeletal disorders in industrial meat cutting. The aim of this study was to objectively evaluate, in real working situations, how knife sharpness changed over a working day cutting meat, and to analyse the impact of sharpening, steeling and meat-cutting activities on these variations. Twenty-two meat-cutting workers from three different companies participated in the study. The methods included measurements of knife sharpness in relation to real work situations and consideration of the way meat-cutting and sharpening operations were organised. Results showed that the type of meat-cutting activities, the steeling strategy adopted by the worker, including the types of tool used, and the overall organisation of the sharpening task all had a significant influence on how knife sharpness evolved over a 2-h period and over an entire working day. To improve MSD prevention, sharpening and steeling operations should not be considered as independent activities, but taken into account as a continuity of working actions. Appropriate assessment of knife sharpness by meat cutters affects how they organise meat-cutting and sharpening tasks. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Surgery or gamma -knife for the treatment of arteriovenous malformations?

    PubMed

    Shigeno, T; Atsuchi, M; Tanaka, J; Goto, K; Ogata, N

    2000-09-01

    Decision making for either surgery or gamma-knife for the treatment of arteriovenous malformations (AVMs) cannot be uniform. The skill of the neurosurgeon in operating on AVMs is now being compared with that of the gamma-knife. The decision varies from case to case and is to be taken by the neurosurgeon. This report presents three cases in which such decision making was not easy. Case 1 was a non-ruptured cingulate AVM of 2.5 cm diameter in the cingulate cortex. The operative field was anticipated to be very narrow between the parietal bridging veins. Case 2 was a tiny ruptured AVM in the speech-motor area which was buried underneath the cortex. Case 3 was a large ruptured thalamo-stiriate-capsular AVM with feeders from the anterior and posterior choroidal arteries. All cases were operated without serious morbidity. A combination of pre-operative intravascular surgery (cases 1 and 3) or postoperative gamma-knife (case 3) was adopted. In conclusion, there is no unitary rule to decide on surgery or gamma-knife for the treatment of AVMs. It depends on what good or harm the responsible surgeon or the gamma-knife does.

  4. The cutting edge - Micro-CT for quantitative toolmark analysis of sharp force trauma to bone.

    PubMed

    Norman, D G; Watson, D G; Burnett, B; Fenne, P M; Williams, M A

    2018-02-01

    Toolmark analysis involves examining marks created on an object to identify the likely tool responsible for creating those marks (e.g., a knife). Although a potentially powerful forensic tool, knife mark analysis is still in its infancy and the validation of imaging techniques as well as quantitative approaches is ongoing. This study builds on previous work by simulating real-world stabbings experimentally and statistically exploring quantitative toolmark properties, such as cut mark angle captured by micro-CT imaging, to predict the knife responsible. In Experiment 1 a mechanical stab rig and two knives were used to create 14 knife cut marks on dry pig ribs. The toolmarks were laser and micro-CT scanned to allow for quantitative measurements of numerous toolmark properties. The findings from Experiment 1 demonstrated that both knives produced statistically different cut mark widths, wall angle and shapes. Experiment 2 examined knife marks created on fleshed pig torsos with conditions designed to better simulate real-world stabbings. Eight knives were used to generate 64 incision cut marks that were also micro-CT scanned. Statistical exploration of these cut marks suggested that knife type, serrated or plain, can be predicted from cut mark width and wall angle. Preliminary results suggest that knives type can be predicted from cut mark width, and that knife edge thickness correlates with cut mark width. An additional 16 cut marks walls were imaged for striation marks using scanning electron microscopy with results suggesting that this approach might not be useful for knife mark analysis. Results also indicated that observer judgements of cut mark shape were more consistent when rated from micro-CT images than light microscopy images. The potential to combine micro-CT data, medical grade CT data and photographs to develop highly realistic virtual models for visualisation and 3D printing is also demonstrated. This is the first study to statistically explore simulated real-world knife marks imaged by micro-CT to demonstrate the potential of quantitative approaches in knife mark analysis. Findings and methods presented in this study are relevant to both forensic toolmark researchers as well as practitioners. Limitations of the experimental methodologies and imaging techniques are discussed, and further work is recommended. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Long-Term Results of Gamma Knife Radiosurgery for Intracranial Meningioma

    PubMed Central

    Jang, Chang Ki; Jung, Hyun Ho; Chang, Jong Hee; Chang, Jin Woo; Park, Yong Gou

    2015-01-01

    Background The predominant treatment modality for meningioma is surgical resection. However, gamma knife radiosurgery is also an important treatment modality for meningioma that is small or cannot be completely removed because of its location. In this study, we evaluated the effectiveness and long-term results of radiosurgical treatment for meningioma in our institution. Methods We studied 628 patients (130 men and 498 women) who underwent gamma knife radiosurgery for intracranial meningioma, which is radiologically diagnosed, from Jan 2008 to Nov 2012. We included patients with single lesion meningioma, and followed up after 6 months with imaging, and then at 24 months with a clinical examination. Patients with high-grade meningioma or multiple meningiomas were excluded. We analyzed each of the factors associated with progression free survival. The median patient's age was 56.8 years. Maximal dosage was 27.8 Gy and marginal dosage was 13.9 Gy. Results The overall tumor control rate was 95%. Twenty-eight patients (4.4%) showed evidence of tumor recurrence. Ninety-eight patients (15%) developed peritumoral edema (PTE) after gamma-knife surgery; two of them (2%) underwent surgical resections due to PTE. Nine patients had craniotomy and tumor removal after gamma knife surgery. Conclusion Gamma knife surgery for intracranial meningioma has proven to be a safe and effective treatment tool with successful long-term outcomes. Gamma knife radiosurgery can be especially effective in cases of remnant meningioma after surgical resection or where PTE is not present. PMID:26605265

  6. Evaluation of holmium laser versus cold knife in optical internal urethrotomy for the management of short segment urethral stricture.

    PubMed

    Jain, Sudhir Kumar; Kaza, Ram Chandra Murthy; Singh, Bipin Kumar

    2014-10-01

    SACHSE COLD KNIFE IS CONVENTIONALLY USED FOR OPTICAL INTERNAL URETHROTOMY INTENDED TO MANAGE URETHRAL STRICTURES AND HO: YAG laser is an alternative to it. The aim of this study was to evaluate the role of urethral stricture treatment outcomes, efficacy, and complications using cold knife and Ho: YAG (Holmium laser) for optical internal urethrotomy. In this prospective study included, 90 male patients age >18 years, with diagnosis of urethral stricture admitted for internal optical urethrotomy during April 2010 to March 2012. The patients were randomized into two groups containing 45 patients each using computer generated random number. In group A (Holmium group), internal urethrotomy was done with Holmium laser and in group B (Cold knife group) Sachse cold knife was used. Patients were followed up for 6 months after surgery in Out Patient Department on 15, 30 and 180 post-operative days. At each follow up visit physical examination, and uroflowmetry was performed along with noting complaints, if any. The peak flow rates (PFR) were compared between the two groups on each follow up. At 180 days (6 month interval) the difference between mean of PFR for Holmium and Cold knife group was statistically highly significant (P < 0.001). Complications were seen in 12.22% of cases. Both modalities are effective in providing immediate relief to patients with single and short segment (<2 cm long) urethral strictures but more sustained response was attained with Cold knife urethrotomy.

  7. Simple Schlieren Light Meter

    NASA Technical Reports Server (NTRS)

    Rhodes, David B.; Franke, John M.; Jones, Stephen B.; Leighty, Bradley D.

    1992-01-01

    Simple light-meter circuit used to position knife edge of schlieren optical system to block exactly half light. Enables operator to check quickly position of knife edge between tunnel runs to ascertain whether or not in alignment. Permanent measuring system made part of each schlieren system. If placed in unused area of image plane, or in monitoring beam from mirror knife edge, provides real-time assessment of alignment of schlieren system.

  8. Occurrence and molecular characterization of cultivable mesophilic and thermophilic obligate anaerobic bacteria isolated from paper mills.

    PubMed

    Suihko, Maija-Liisa; Partanen, Laila; Mattila-Sandholm, Tiina; Raaska, Laura

    2005-08-01

    The aim of this work was to characterize the cultivable obligate anaerobic bacterial population in paper mill environments. A total of 177 anaerobically grown bacterial isolates were screened for aerotolerance, from which 67 obligate anaerobes were characterized by automated ribotyping and 41 were further identified by partial 16S rDNA sequencing. The mesophilic isolates indicated 11 different taxa (species) within the genus Clostridium and the thermophilic isolates four taxa within the genus Thermoanaerobacterium and one within Thermoanaerobacter (both formerly Clostridium). The most widespread mesophilic bacterium was closely related to C. magnum and occurred in three of four mills. One mill was contaminated with a novel mesophilic bacterium most closely related to C. thiosulfatireducens. The most common thermophile was T. thermosaccharolyticum, occurring in all four mills. The genetic relationships of the mill isolates to described species indicated that most of them are potential members of new species. On the basis of identical ribotypes clay could be identified to be the contamination source of thermophilic bacteria. Automated ribotyping can be a useful tool for the identification of clostridia as soon as comprehensive identification libraries are available.

  9. Towards medicinal mechanochemistry: evolution of milling from pharmaceutical solid form screening to the synthesis of active pharmaceutical ingredients (APIs).

    PubMed

    Tan, Davin; Loots, Leigh; Friščić, Tomislav

    2016-06-14

    This overview highlights the emergent area of mechanochemical reactions for making active pharmaceutical ingredients (APIs), and covers the latest advances in the recently established area of mechanochemical screening and synthesis of pharmaceutical solid forms, specifically polymorphs, cocrystals, salts and salt cocrystals. We also provide an overview of the most recent developments in pharmaceutical uses of mechanochemistry, including real-time reaction monitoring, techniques for polymorph control and approaches for continuous manufacture using twin screw extrusion, and more. Most importantly, we show how the overlap of previously unrelated areas of mechanochemical screening for API solid forms, organic synthesis by milling, and mechanochemical screening for molecular recognition, enables the emergence of a new research discipline in which different aspects of pharmaceutical and medicinal chemistry are addressed through mechanochemistry rather than through conventional solution-based routes. The emergence of such medicinal mechanochemistry is likely to have a strong impact on future pharmaceutical and medicinal chemistry, as it offers not only access to materials and reactivity that are sometimes difficult or even impossible to access from solution, but can also provide a general answer to the demands of the pharmaceutical industry for cleaner, safer and efficient synthetic solutions.

  10. Kitchen knives and homicide: a systematic study of people charged with murder in the Lothian and Borders region of Scotland.

    PubMed

    Kidd, S H; Hughes, N S; Crichton, J H M

    2014-07-01

    A recent English study demonstrated high rates of kitchen knife use in homicides by mentally disordered offenders subject to independent inquiries. Everyone accused of homicide in Scotland undergoes psychiatric examination; all such evaluations in a Scottish region between 2006 and 2011 were systematically analysed to identify homicide characteristics. It was hypothesised that kitchen knives would be the commonest sharp instruments used, and would be associated with unplanned domestic homicide against known victims, with no independent association with mental disorder. Kitchen knives were used in 32 of 55 homicides: 94% of 34 sharp object homicides (p < 0.05). No independent association was found between kitchen knife use and planning, location, relationship, intoxication or mental disorder. Kitchen knife use in homicide appears to be a significant public health issue, and not only in the mentally disordered population. Research is recommended into kitchen knife use in non-fatal violence, and weapon control in populations at increased risk of knife violence.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mihailescu, Lucian

    This disclosure provides systems, methods, and apparatus related to ion beam therapy. In one aspect, a system includes a position sensitive detector and a collimator. The position sensitive detector configured to detect gamma rays generated by an ion beam interacting with a target. The collimator is positioned between the target and the position sensitive detector. The collimator includes a plurality of knife-edge slits, with a first knife-edge slit intersecting with a second knife-edge slit.

  12. Comparison of penumbra regions produced by ancient Gamma knife model C and Gamma ART 6000 using Monte Carlo MCNP6 simulation.

    PubMed

    Banaee, Nooshin; Asgari, Sepideh; Nedaie, Hassan Ali

    2018-07-01

    The accuracy of penumbral measurements in radiotherapy is pivotal because dose planning computers require accurate data to adequately modeling the beams, which in turn are used to calculate patient dose distributions. Gamma knife is a non-invasive intracranial technique based on principles of the Leksell stereotactic system for open deep brain surgeries, invented and developed by Professor Lars Leksell. The aim of this study is to compare the penumbra widths of Leksell Gamma Knife model C and Gamma ART 6000. Initially, the structure of both systems were simulated by using Monte Carlo MCNP6 code and after validating the accuracy of simulation, beam profiles of different collimators were plotted. MCNP6 beam profile calculations showed that the penumbra values of Leksell Gamma knife model C and Gamma ART 6000 for 18, 14, 8 and 4 mm collimators are 9.7, 7.9, 4.3, 2.6 and 8.2, 6.9, 3.6, 2.4, respectively. The results of this study showed that since Gamma ART 6000 has larger solid angle in comparison with Gamma Knife model C, it produces better beam profile penumbras than Gamma Knife model C in the direct plane. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. The current role of Gamma Knife radiosurgery in the management of intracranial haemangiopericytoma.

    PubMed

    Spina, Alfio; Boari, Nicola; Gagliardi, Filippo; Donofrio, Carmine A; Franzin, Alberto; Mortini, Pietro

    2016-04-01

    Haemangiopericytomas (HPCs) are rare tumours characterised by aggressive behaviour with tendency to local recurrence and to metastasise. WHO grade II and grade III tumours show different progression-free survival and overall survival rates. Gross total tumour resection is still considered the treatment of choice. Adjuvant radiation therapies represent an option in the treatment strategy regardless the extent of resection. Based on this consideration, Gamma Knife radiosurgery has been introduced either as a primary treatment or as an adjuvant treatment for residual or recurrent tumours. A systematic search was performed on PubMed, Web of Science and Google Scholar for clinical series reporting Gamma Knife radiosurgery, Cyberknife and Linear Accelerator (LINAC) for the management of intracranial HPCs. Fourteen studies focusing on the effects of Gamma Knife radiosurgery for intracranial HPCs were included. Four studies reported data on Cyberknife radiosurgery and LINAC. A total of 208 patients harbouring 366 tumours have been reported. Patient's features, radiosurgical treatment characteristics and follow-up data of the pertinent literature have been critically revised. Gamma Knife radiosurgery and the other radiosurgical techniques represent a feasible and effective therapy in the management of HPCs. Tumour control and survival rate are comparable to those reported for radiotherapy. Further studies should be focused to define the exact role of Gamma Knife radiosurgery in the management of HPCs.

  14. Gamma knife radiosurgery in movement disorders: Indications and limitations.

    PubMed

    Higuchi, Yoshinori; Matsuda, Shinji; Serizawa, Toru

    2017-01-01

    Functional radiosurgery has advanced steadily during the past half century since the development of the gamma knife technique for treating intractable cancer pain. Applications of radiosurgery for intracranial diseases have increased with a focus on understanding radiobiology. Currently, the use of gamma knife radiosurgery to ablate deep brain structures is not widespread because visualization of the functional targets remains difficult despite the increased availability of advanced neuroimaging technology. Moreover, most existing reports have a small sample size or are retrospective. However, increased experience with intraoperative neurophysiological evaluations in radiofrequency thalamotomy and deep brain stimulation supports anatomical and neurophysiological approaches to the ventralis intermedius nucleus. Two recent prospective studies have promoted the clinical application of functional radiosurgery for movement disorders. For example, unilateral gamma knife thalamotomy is a potential alternative to radiofrequency thalamotomy and deep brain stimulation techniques for intractable tremor patients with contraindications for surgery. Despite the promising efficacy of gamma knife thalamotomy, however, these studies did not include sufficient follow-up to confirm long-term effects. Herein, we review the radiobiology literature, various techniques, and the treatment efficacy of gamma knife radiosurgery for patients with movement disorders. Future research should focus on randomized controlled studies and long-term effects. © 2016 International Parkinson and Movement Disorder Society. © 2016 International Parkinson and Movement Disorder Society.

  15. Single stab injuries.

    PubMed

    Burke, Michael P; Baber, Yeliena; Cheung, Zoe; Fitzgerald, Mark

    2018-05-01

    Determining the manner of death in cases involving multiple stab injuries from a knife is generally straightforward. The medico-legal investigation of a stabbing death caused by a single stab injury from a knife comprises a smaller but potentially more problematic subset of forensic cases. We reviewed our institute's experience with single stab injuries and endeavored to identify features identified at the post-mortem examination which may aid in the differentiation between cases of homicide, suicide and accidental death. The single stab injury was to the left chest in the majority of deaths from homicide and from suicide. Clothing was nearly always involved in cases of homicide, but was also seen in cases of suicide. The knife was found in situ in 9 of the 11 cases of suicide involving a chest injury, but was not seen in any of the cases of homicide. There were no cases of an accidental single stab death from a knife in our records. Clinical data on accidental stab injuries was sought via a search of the medical records of a major tertiary referral hospital. A single non-fatal case of an accidental single stab injury from a knife was identified after the conclusion of our study period. Accidental stab injuries from a knife causing injury or death are rare.

  16. Thermal welding vs. cold knife tonsillectomy: a comparison of voice and speech.

    PubMed

    Celebi, Saban; Yelken, Kursat; Celik, Oner; Taskin, Umit; Topak, Murat

    2011-01-01

    To compare acoustic, aerodynamic and perceptual voice and speech parameters in thermal welding system tonsillectomy and cold knife tonsillectomy patients in order to determine the impact of operation technique on voice and speech. Thirty tonsillectomy patients (22 children, 8 adults) participated in this study. The preferred technique was cold knife tonsillectomy in 15 patients and thermal welding system tonsillectomy in the remaining 15 patients. One week before and 1 month after surgery the following parameters were estimated: average of fundamental frequency, Jitter, Shimmer, harmonic to noise ratio, formant frequency analyses of sustained vowels. Perceptual speech analysis and aerodynamic measurements (maximum phonation time and s/z ratio) were also conducted. There was no significant difference in any of the parameters between cold knife tonsillectomy and thermal welding system tonsillectomy groups (p>0.05). When the groups were contrasted among themselves with regards to preoperative and postoperative rates, fundamental frequency was found to be significantly decreased after tonsillectomy in both of the groups (p<0.001). First formant for the vowel /a/ in the cold knife tonsillectomy group and for the vowel /i/ in the thermal welding system tonsillectomy group, second formant for the vowel /u/ in the thermal welding system tonsillectomy group and third formant for the vowel /u/ in the cold knife tonsillectomy group were found to be significantly decreased (p<0.05). The surgical technique, whether it is cold knife or thermal welding system, does not appear to affect voice and speech in tonsillectomy patients. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  17. A cross-sectional study of knife injuries at a London major trauma centre.

    PubMed

    Pallett, J R; Sutherland, E; Glucksman, E; Tunnicliff, M; Keep, J W

    2014-01-01

    No national recording systems for knife injuries exist in the UK. Understanding the true size and nature of the problem of knife injuries is the first stage in reducing the burden of this injury. The aim of this study was to survey every knife injury seen in a single inner city emergency department (ED) over a one-year period. A cross-sectional observational study was performed of all patients attending with a knife injury to the ED of a London major trauma centre in 2011. Demographic characteristics, patterns of injury, morbidity and mortality data were collected. A total of 938 knife injuries were identified from 127,191 attendances (0.77% of all visits) with a case fatality rate of 0.53%. A quarter (24%) of the major trauma team's caseload was for knife injuries. Overall, 44% of injuries were selfreported as assaults, 49% as accidents and 8% as deliberate self-harm. The highest age specific incident rate occurred in the 16-24 year age category (263/100,000). Multiple injuries were seen in 19% of cases, of which only 81% were recorded as assaults. The mean length of stay for those admitted to hospital was 3.04 days. Intrathoracic injury was seen in 26% of cases of chest trauma and 24% of abdominal injuries had a second additional chest injury. Violent intentional injuries are a significant contributory factor to the workload of the major trauma team at this centre. This paper contributes to a more comprehensive understanding of the nature of these injuries seen in the ED.

  18. A cross-sectional study of knife injuries at a London major trauma centre

    PubMed Central

    Sutherland, E; Glucksman, E; Tunnicliff, M; Keep, JW

    2014-01-01

    INTRODUCTION No national recording systems for knife injuries exist in the UK. Understanding the true size and nature of the problem of knife injuries is the first stage in reducing the burden of this injury. The aim of this study was to survey every knife injury seen in a single inner city emergency department (ED) over a one-year period. METHODS A cross-sectional observational study was performed of all patients attending with a knife injury to the ED of a London major trauma centre in 2011. Demographic characteristics, patterns of injury, morbidity and mortality data were collected. RESULTS A total of 938 knife injuries were identified from 127,191 attendances (0.77% of all visits) with a case fatality rate of 0.53%. A quarter (24%) of the major trauma team’s caseload was for knife injuries. Overall, 44% of injuries were selfreported as assaults, 49% as accidents and 8% as deliberate self-harm. The highest age specific incident rate occurred in the 16–24 year age category (263/100,000). Multiple injuries were seen in 19% of cases, of which only 81% were recorded as assaults. The mean length of stay for those admitted to hospital was 3.04 days. Intrathoracic injury was seen in 26% of cases of chest trauma and 24% of abdominal injuries had a second additional chest injury. CONCLUSIONS Violent intentional injuries are a significant contributory factor to the workload of the major trauma team at this centre. This paper contributes to a more comprehensive understanding of the nature of these injuries seen in the ED. PMID:24417825

  19. Cost analysis of Gamma Knife stereotactic radiosurgery.

    PubMed

    Griffiths, Alison; Marinovich, Luke; Barton, Michael B; Lord, Sarah J

    2007-01-01

    Stereotactic radiosurgery (SRS) is used to treat intracranial lesions and vascular malformations as an addition or replacement to whole brain radiotherapy and microsurgery. SRS can be delivered by hardware and software appended to standard linear accelerators (Linacs) or by dedicated systems such as Gamma Knife, which has been proposed as a more accurate and user friendly technology. Internationally, dedicated systems have been funded, despite limitations in evidence. However, some countries including Australia have not recommended additional reimbursement for dedicated systems. This study compares the costs of Linac radiosurgery with Gamma Knife radiosurgery. Due to limited evidence on comparative effects, the economic analysis was restricted to a cost evaluation. The base-case analysis assumed a modified Linac was used only to treat SRS patients. However, because a modified Linac could be used to treat other radiotherapy patients, a second analysis assumed spare time was used to meet other radiotherapy needs, and Linac capital costs were apportioned according to SRS use. The incremental cost of Gamma Knife versus a modified Linac was estimated as AU$209 per patient. This result is sensitive to variations in assumptions. A second analysis proportioning capital costs according to SRS use showed that Gamma Knife may cost up to AU$1673 more per patient. Gamma Knife may be cost competitive only if demand for SRS services is high enough to fully use equipment working time. However, given low patient demand and competing radiotherapy needs, Gamma Knife appears more costly and further evidence of survival or quality of life advantages may be required to justify reimbursement.

  20. [Case-control study on needle-knife to cut off the medial branch of the lumbar posterior ramus under C-arm guiding for the treatment of low back pain caused by lumbar facet osteoarthritis].

    PubMed

    Lu, Di; Xu, Wei-xing; Ding, Wei-Guo; Guo, Qiao-Feng; Ma, Gou-ping; Zhu, Wei-min

    2013-03-01

    To study the clinical efficacy of needle-knife to cut off the medial branch of the lumbar posterior ramus under C-arm guiding to treat low back pain caused by lumbar facet osteoarthritis. From July 2009 to June 2011, 60 patients with low back pain caused by lumbar facet osteoarthritis were reviewed,including 34 males and 26 females, ranging in age from 39 to 73 years old,averaged 61.9 years old; the duration of the disease ranged from 6 to 120 months, with a mean of 18.9 months. All the patients were divided into two groups, 30 patients (18 males and 12 females, ranging in age from 39 to 71 years old, needle-knife group) were treated with needle-knife to cut off medial branch of the lumbar posterior ramus under C -arm guiding and the other 30 patients(16 males and 14 females, ranging in age from 41 to 73 years old, hormone injection group) were treated with hormone injection in lumbar facet joint under C-arm guiding. The preoperative JOA scores and the scores at the 1st, 12th and 26th weeks after treatment were analyzed. Before treatment,the JOA scores between the two groups had no significant difference (P= 0.479); after 1 week of treatment, the JOA scores between the two groups had significant difference (P= 0.040), the improvement rate of hormone injection group was superior than that of the needle-knife group,which were (58.73+/-18.20)% in needle-knife group and (71.10+/-22.19)% in hormone injection group; after 12 weeks of treatment, the JOA scores between the two groups had no significant difference(P=0.569), and the improvement rate between the two groups had no significant difference,which were (50.09+/-19.33)% in the needle-knife group and (48.70+/-18.36)%) in the hormone injection group; after 26 weeks of treatment,the JOA scores between the two groups had significant difference (P=0.000), the improvement rate of hormone injection group was superior than that of the needle-knife group,which were (48.56+/-28.24)% in needle-knife group and (15.62+/-11.23 )% in hormone injection group. Using needle-knife to cut off the medial branch of the lumbar posterior ramus could get longer efficacy than hormone injection in the treatment of lumbar facet osteoarthritis.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    McMakin, Douglas L.; Sheen, David M.; Hall, Thomas E.

    Pacific Northwest National Laboratory researchers have been at the forefront of developing innovative screening systems to enhance security and a novel imaging system to provide custom-fit clothing using holographic radar imaging techniques. First-of-a-kind cylindrical holographic imaging systems have been developed to screen people at security checkpoints for the detection of concealed, body worn, non-metallic threats such as plastic and liquid explosives, knifes and contraband. Another embodiment of this technology is capable of obtaining full sized body measurements in near real time without the person under surveillance removing their outer garments. Radar signals readily penetrate clothing and reflect off the watermore » in skin. This full body measurement system is commercially available for best fitting ready to wear clothing, which was the first “biometric” application for this technology. One compelling feature of this technology for security biometric applications is that it can see effectively through disguises, appliances and body hair.« less

  2. Gamma knife surgery-induced ependymoma after the treatment of meningioma - a case report.

    PubMed

    Wang, Ke; Pan, Li; Che, Xiaoming; Lou, Meiqing

    2012-01-01

    Gamma knife surgery is widely used for a number of neurological disorders. However, little is known about its long-term complications such as carcinogenic risks. Here, we present a case of a radiosurgery-induced ependymoma by gamma knife surgery for the treatment of a spinal meningioma in a 7-year-old patient. In light of reviewing the previous reports, we advocate high caution in making young patients receive this treatment.

  3. Cleaning mechanism of particle contaminants on large aperture optical components by using air knife sweeping technology

    NASA Astrophysics Data System (ADS)

    Niu, Longfei; Liu, Hao; Miao, Xinxiang; Lv, Haibing; Yuan, Xiaodong; Zhou, Hai; Yao, Caizhen; Zhou, Guorui; Li, Qin

    2017-05-01

    The cleaning mechanism of optical surface particle contaminants in the light pneumatic tube was simulated based on the static equations and JKR model. Cleaning verification experiment based on air knife sweeping system and on-line monitoring system in high power laser facility was set up in order to verify the simulated results. Results showed that the removal ratio is significantly influenced by sweeping velocity and angle. The removal ratio can reach to 94.3% by using higher input pressure of the air knife, demonstrating that the air knife sweeping technology is useful for maintaining the surface cleanliness of optical elements, and thus guaranteeing the long-term stable running of the high power laser facility.

  4. Super-resolved terahertz microscopy by knife-edge scan

    NASA Astrophysics Data System (ADS)

    Giliberti, V.; Flammini, M.; Ciano, C.; Pontecorvo, E.; Del Re, E.; Ortolani, M.

    2017-08-01

    We present a compact, all solid-state THz confocal microscope operating at 0.30 THz that achieves super-resolution by using the knife-edge scan approach. In the final reconstructed image, a lateral resolution of 60 μm ≍ λ/17 is demonstrated when the knife-edge is deep in the near-field of the sample surface. When the knife-edge is lifted up to λ/4 from the sample surface, a certain degree of super-resolution is maintained with a resolution of 0.4 mm, i.e. more than a factor 2 if compared to the diffraction-limited scheme. The present results open an interesting path towards super-resolved imaging with in-depth information that would be peculiar to THz microscopy systems.

  5. Predicting risk of nonmelanoma skin cancer and premalignant skin lesions in renal transplant recipients.

    PubMed

    Urwin, Helen R; Jones, Peter W; Harden, Paul N; Ramsay, Helen M; Hawley, Carmel M; Nicol, David L; Fryer, Anthony A

    2009-06-15

    Nonmelanoma skin cancer (NMSC) and associated premalignant lesions represent a major complication after transplantation, particularly in areas with high ultraviolet radiation (UVR) exposure. The American Society of Transplantation has proposed annual NMSC screening for all renal transplant recipients. The aim of this study was to develop a predictive index (PI) that could be used in targeted screening. Data on patient demographics, UVR exposure, and other clinical parameters were collected on 398 adult recipients recruited from the Princess Alexandra Hospital, Brisbane. Structured interview, skin examination, biopsy of lesions, and review of medical/pathologic records were performed. Time to presentation with the first NMSC was assessed using Cox's regression models and Kaplan-Meier estimates used to assess detection of NMSC during screening. Stepwise selection identified age, outdoor UVR exposure, living in a hot climate, pretransplant NMSC, childhood sunburning, and skin type as predictors. The PI generated was used to allocate patients into three screening groups (6 months, 2 years, and 5 years). The survival curves of these groups were significantly different (P<0.0001). Jack-knife validation correctly allocated all patients into the appropriate group. We have developed a simple PI to enable development of targeted NMSC surveillance strategies.

  6. [Efficacy comparison between needle-knife therapy and acupuncture-cupping for cervical spondylosis of cervical type].

    PubMed

    Cao, Li; Wang, Fan

    2014-05-01

    To compare the efficacy differences between needle-knife therapy and acupuncture-cupping for treatment of cervical spondylosis (CS) of cervical type. Sixty cases of CS were randomly divided into a needle-knife group (30 cases) and an acupuncture-cupping group (30 cases). The needle-knife therapy was applied at points among superior nuchal line of occipital bone, bilateral neck muscle, neck centerline, trapezius and medial border scapula for only once. In the acupuncture-cupping group, acupuncture was applied at Fengchi (GB 20), Fengfu (GV 16), Tianzhu (BL 10), Dazhui (GV 14), Jianjing (GB 21), Jiaji (Ex-B2, from C4 to C6), Houxi (SI 3) and Ashi point, followed by cupping on local skin, once every other day for totally six times. The score of neck stiffness and visual analogue scale (VAS) were observed before and after treatment, in follow-up of 1, 3 and 6 months after treatment in the two groups, and the efficacy was compared. In the needle-knife group, 9 cases were cured, 12 cases were markedly effective, 8 cases were effective and 1 case was failed; the total effective rate was 96.7% (29/30) and the cured and markedly effective rate was 70.0% (21/30). In the acupuncture-cupping group, 8 cases were cured, 9 cases were markedly effective, 11 cases were effective and 2 cases were failed; the total effective rate was 93.3% (28/30) and the cured and markedly effective rate was 56.7% (17/30). The difference of total effective rate in the two groups was not statistically significant (P > 0.05), but the cured and markedly effective rate of needle-knife group was significantly superior to that of acupuncture-cupping group (P < 0.05). The needle-knife therapy was significantly superior to acupuncture-cupping on improvement of neck stiffness in the follow-up of 1, 3, 6 months after treatment (P < 0.05, P < 0.001); both treatments were effective on relief of neck pain, but the needle-knife group had better effects in the follow-up of 3 and 6 months after treatment compared with acupuncture-cupping group (both P < 0.01). The needle-knife therapy has better effects on neck stiffness and pain relief than acupuncture-cupping, and it is more treatment time saving.

  7. Laparoscopic pyloromyotomy: is a knife really necessary?

    PubMed

    Jain, Vishesh; Choudhury, Subhasis Roy; Chadha, Rajiv; Puri, Archana; Naga, Abhimanyu Singh

    2012-02-01

    Laparoscopic pyloromyotomy (LP) is currently accepted as a suitable treatment modality for infantile hypertrophic pyloric stenosis (IHPS). In this report, we describe some technical modifications of LP using a 3- or 5-mm hook with electrocautery as a substitute for a knife for incising the pylorus. The outcomes of LP using a standard retractable pyloromyotomy knife are compared with those of LP using a hook electrocautery. The patients with ultrasound proven IHPS who had undergone LP in a single institution from December 2008 to April 2010 were retrospectively analyzed. Incision on the pylorus was made with a 3-mm pyloromyotomy knife in the initial 12 cases. However, in the latter part of the study, a 3- or 5-mm hook with electrocautery was used for the incision. A Maryland dissector was used for completing the pyloromyotomy. The results were compared in terms of duration of surgery, complications, time taken to establish the first full feed, requirement of analgesics, postoperative emesis, and postoperative stay in the hospital. Independent sample t test and the Chi-square test were used for statistical analysis. Of the 27 patients analyzed, 12 underwent LP using a pyloromyotomy knife and the remaining 15 patients were operated on using a hook with electrocautery instead of the knife. The operating time, time taken to establish the first full feed, and duration of hospital stay were comparable among the two groups with no statistically significant difference. No complications were recorded in either group. Use of hook electrocautery for incising the pylorus provides a bloodless field without affecting the postoperative recovery and outcome. It also obviates any need of specialized instruments like a pyloromyotomy knife or other sharp instruments for pyloric incision.

  8. Endoscopic submucosal dissection of early colorectal neoplasms with a monopolar scissor-type knife: short- to long-term outcomes.

    PubMed

    Kuwai, Toshio; Yamaguchi, Toshiki; Imagawa, Hiroki; Sumida, Yuki; Takasago, Takeshi; Miyasako, Yuki; Nishimura, Tomoyuki; Iio, Sumio; Yamaguchi, Atsushi; Kouno, Hirotaka; Kohno, Hiroshi; Ishaq, Sauid

    2017-09-01

    Background and study aims  Endoscopic submucosal dissection (ESD) for colorectal neoplasms remains challenging because of technical issues imposed by the complex anatomical features of the large intestine. We evaluated the feasibility, and the short- and long-term clinical outcomes of ESD for early colorectal neoplasms performed using the Stag-beetle Knife Jr. (SB Knife Jr.) Patients and methods  We retrospectively assessed 228 patients who underwent ESD for 247 colorectal lesions with the SB Knife Jr. Clinicopathological characteristics of the neoplasms, complications, and various short- and long-term outcomes were evaluated. Results  Mean tumor size was 34.3 mm and median procedure time was 76 minutes. The SB Knife Jr. achieved 98.4 % en bloc resection, 93.9 % complete resection, and 85.4 % curative resection. No perforations occurred during the procedure, and a delayed bleeding rate of 2.4 % was observed. Long-term outcomes were favorable with no distant recurrence, 1.1 % local recurrence, a 5-year overall survival rate of 94.1 % and 5-year tumor-specific survival rate of 98.6 % in patients with cancer. Conclusions  ESD using the SB Knife Jr. is technically efficient and safe in treating early colorectal neoplasms and is associated with favorable short- and long-term outcomes. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Flex-rigid pleuroscopic biopsy with the SB knife Jr is a novel technique for diagnosis of malignant or benign fibrothorax.

    PubMed

    Wang, Xiao-Bo; Yin, Yan; Miao, Yuan; Eberhardt, Ralf; Hou, Gang; Herth, Felix J; Kang, Jian

    2016-11-01

    Diagnosing pleural effusion is challenging, especially in patients with malignant or benign fibrothorax, which is difficult to sample using standard flexible forceps (SFF) via flex-rigid pleuroscopy. An adequate sample is crucial for the differential diagnosis of malignant fibrothorax (malignant pleural mesothelioma, metastatic lung carcinoma, etc.) from benign fibrothorax (benign asbestos pleural disease, tuberculous pleuritis, etc.). Novel biopsy techniques are required in flex-rigid pleuroscopy to improve the sample size and quality. The SB knife Jr, which is a scissor forceps that uses a mono-pole high frequency, was developed to allow convenient and accurate resection of larger lesions during endoscopic dissection (ESD). Herein, we report two patients with fibrothorax who underwent a pleural biopsy using an SB knife Jr to investigate the potential use of this tool in flex-rigid pleuroscopy when pleural lesions are difficult to biopsy via SFF. The biopsies were successful, with sufficient size and quality for definitive diagnosis. We also successfully performed adhesiolysis with the SB knife Jr in one case, and adequate biopsies were conducted. No complications were observed. Electrosurgical biopsy with the SB knife Jr during flex-rigid pleuroscopy allowed us to obtain adequate samples for the diagnosis of malignant versus benign fibrothorax, which is usually not possible with SFF. The SB knife Jr also demonstrated a potential use for pleuropulmonary adhesions.

  10. Analytical and experimental investigation of rubbing interaction in labyrinth seals for a liquid hydrogen fuel pump. [space shuttle main engine

    NASA Technical Reports Server (NTRS)

    Dolan, F. X.; Kennedy, F. E.; Schulson, E. M.

    1984-01-01

    Cracking of the titanium knife edges on the labyrinth seals of the liquid hydrogen fuel pump in the Space Shuttle main engine is considered. Finite element analysis of the thermal response of the knife edge in sliding contact with the wear ring surface shows that interfacial temperatures can be quite high and they are significantly influenced by the thermal conductivity of the surfaces in rubbing contact. Thermal shock experiments on a test specimen similar to the knife edge geometry demonstrate that cracking of the titanium alloy is possible in a situation involving repeated thermal cycles over a wide temperature range, as might be realized during a rub in the liquid hydrogen fuel pump. High-speed rub interaction tests were conducted using a representative knife edge and seal geometry over a broad range of interaction rates and alternate materials were experimentally evaluated. Plasma-sprayed aluminum-graphite was found to be significantly better than presently used aluminum alloy seals from the standpoint of rub performance. Ion nitriding the titanium alloy knife-edges also improved rub performance compared to the untreated baseline.

  11. Sphincterotomy by triple lumen needle knife using guide wire in patients with Billroth II gastrectomy

    PubMed Central

    Park, Su Bum; Kim, Hyung Wook; Kang, Dae Hwan; Choi, Cheol Woong; Yoon, Ki Tae; Cho, Mong; Song, Byeong Jun

    2013-01-01

    AIM: To investigate the usefulness of a guide wire and triple lumen needle knife for removing stones in Billroth II (B-II) gastrectomy patients. METHODS: Endoscopic sphincterotomy in patients with B-II gastrectomy is challenging. We used a new guide wire technique involving sphincterotomy by triple lumen needle knife through a forward-viewing endoscopy. This technique was performed in nine patients between August 2010 and June 2012. Sphincterotomy as described above was performed. Adequate sphincterotomy, successful stone removal, and complications were investigated prospectively. RESULTS: Sphincterotomy by triple lumen needle knife using guide wire was successful in all nine patients. Sphincterotomy started towards the 4-5 o’clock direction and continued to the upper margin of the papillary roof. Complete stone removal in one session was achieved in all patients. There were no procedure related complications, such as bleeding, pancreatitis, or perforation. CONCLUSION: In patients with B-II gastrectomy, guide wire using sphincterotomy by triple lumen needle knife through a forward-viewing endoscopy seems to be an effective and safe procedure for the removal of common bile duct stones. PMID:24409069

  12. An experimental investigation of rubbing interaction in labyrinth seals at cryogenic temperature

    NASA Technical Reports Server (NTRS)

    Dolan, F. X.; Kennedy, F. E.; Schulson, E. M.

    1985-01-01

    An experimental program was carried out to address issues related to the observed cracking of the titanium knife edges on the labyrinth seals of the high pressure fuel pump (HPFP) in the Space Shuttle main engine (SSME). Thermal shock experiments were carried out using a jet specimen with geometry similar to the knife edge geometry. These tests demonstrate that cracking of the titanium alloy is possible in a situation involving repeated thermal cycles over a wide temperature range, as might be realized during a rub in the liquid hydrogen fuel pump. High speed rub interaction tests were conducted using a representative knife edge and seal geometry over a broad range of interaction rates. Alternative materials were also experimentally evaluated. These tests provide information which can be used to design improved labyrinth seals for the HPFP of the SSME. In particular, plasma-sprayed aluminum-graphite was found to be significantly better than aluminum alloy seals used at present from the standpoint of rub performance. Ion nitriding of the titanium alloy knife edges was also found to improve rub performance compared with the untreated baseline knife edge material.

  13. Age and automation interact to influence performance of a simulated luggage screening task.

    PubMed

    Wiegmann, Douglas; McCarley, Jason S; Kramer, Arthur F; Wickens, Christopher D

    2006-08-01

    An experiment examined the impact of automation on young and old adults' abilities to detect threat objects in a simulated baggage-screening task. Younger and older adult participants viewed X-ray images of cluttered baggage, 20% of which contained a hidden knife. Some participants were provided an automated aid with a hit rate of 0.90 and a false alarm rate of 0.25. The aid provided assistance to participants in one of three forms: a text message that appeared before the stimulus image; a text message that appeared following the stimulus image; or a spatial cue concurrent with the stimulus image. Control participants performed the task with no assistance from an aid. Spatial cuing improved performance for both age groups. Text cuing improved young adults' performance, but had no benefit for older participants. Effects were similar whether the text cue preceded or followed the search stimulus itself. Results indicate that spatial cuing rather than text alerts may be more effective in aiding performance during a baggage screening task and such benefits are likely to occur regardless of operator age.

  14. Souvenir knife: a retained transcranial knife blade.

    PubMed

    Davis, Neil L; Kahana, Tzipi; Hiss, Jehuda

    2004-09-01

    Upon necroscopic examination of a homeless male found comatose in the street and pronounced dead at a medical center 12 hours later, a sharp tip of a knife lodged in the right parietal region of his skull was incidentally discovered. The blade transected the diploe and penetrated the cerebral cortex. Subsequent police investigation revealed that this was the remnant of a stabbing attempt on his life several months prior to his death. The cause of death was determined to be unrelated to the metallic blade fragment, thus making it a truly incidental and rare finding of a "souvenir knife." Nevertheless, since the injury sustained in the stabbing was potentially life threatening, the investigation into that assault was reopened.A case report is presented, along with a brief review of the literature on "souvenir objects."

  15. Knife wound to the posterior fossa in a child.

    PubMed

    Mohan, Avinash L; Slim, Michel; Benzil, Deborah L

    2005-03-01

    Knife wounds to the posterior fossa are a rare occurrence, especially in children. We report an 8-year-old girl who sustained a penetrating knife injury through the occipital bone into the posterior fossa. On presentation, the large knife blade was firmly embedded in her head. Radiographic evaluation was limited to plain X-rays because of the large size and sharpness of the embedded blade. Innovative positioning was used during intubation and then the patient was positioned semi-prone on the operating room table. The blade was surgically removed and the dura was closed. Atypical penetrating cranial injuries in children may require the treatment team to take a creative approach to the evaluation and repair of the lesion in order to maximize patient safety and minimize the risk of neurological injury.

  16. 48. INTERIOR VIEW FROM THE WEST END OF THE AMALGAMATION ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    48. INTERIOR VIEW FROM THE WEST END OF THE AMALGAMATION TABLES LOOKING NORTH TOWARDS THE STAMP BATTERIES WITH AMALGAM TRAPS SHOWN IN THE BOTTOM FOREGROUND. NOTE THE EXTANT EQUIPMENT IN THE FOREGROUND THAT THE PARK USES TO INTERPRET THE MILL. FROM LEFT TO RIGHT, A SCREEN FROM THE MORTAR BOX, A STAMP STOP. A (HUMAN'S) SHOE, A DIE FROM THE BOTTOM OF A MORTAR BOX, AN AMALGAM SCRAPPER AND AN AMALGAM BUCKET. - Standard Gold Mill, East of Bodie Creek, Northeast of Bodie, Bodie, Mono County, CA

  17. Two-year experience with the commercial Gamma Knife Check software.

    PubMed

    Xu, Andy Yuanguang; Bhatnagar, Jagdish; Bednarz, Greg; Novotny, Josef; Flickinger, John; Lunsford, L Dade; Huq, M Saiful

    2016-07-08

    The Gamma Knife Check software is an FDA approved second check system for dose calculations in Gamma Knife radiosurgery. The purpose of this study was to evaluate the accuracy and the stability of the commercial software package as a tool for independent dose verification. The Gamma Knife Check software version 8.4 was commissioned for a Leksell Gamma Knife Perfexion and a 4C unit at the University of Pittsburgh Medical Center in May 2012. Independent dose verifications were performed using this software for 319 radiosurgery cases on the Perfexion and 283 radiosurgery cases on the 4C units. The cases on each machine were divided into groups according to their diagnoses, and an averaged absolute percent dose difference for each group was calculated. The percentage dose difference for each treatment target was obtained as the relative difference between the Gamma Knife Check dose and the dose from the tissue maximum ratio algorithm (TMR 10) from the GammaPlan software version 10 at the reference point. For treatment plans with imaging skull definition, results obtained from the Gamma Knife Check software using the measurement-based skull definition method are used for comparison. The collected dose difference data were also analyzed in terms of the distance from the treatment target to the skull, the number of treatment shots used for the target, and the gamma angles of the treatment shots. The averaged percent dose differences between the Gamma Knife Check software and the GammaPlan treatment planning system are 0.3%, 0.89%, 1.24%, 1.09%, 0.83%, 0.55%, 0.33%, and 1.49% for the trigeminal neuralgia, acoustic neuroma, arteriovenous malformation (AVM), meningioma, pituitary adenoma, glioma, functional disorders, and metastasis cases on the Perfexion unit. The corresponding averaged percent dose differences for the 4C unit are 0.33%, 1.2%, 2.78% 1.99%, 1.4%, 1.92%, 0.62%, and 1.51%, respectively. The dose difference is, in general, larger for treatment targets in the peripheral regions of the skull owing to the difference in the numerical methods used for skull shape simulation in the GammaPlan and the Gamma Knife Check software. Larger than 5% dose differences were observed on both machines for certain targets close to patient skull surface and for certain targets in the lower half of the brain on the Perfexion, especially when shots with 70 and/or 110 gamma angles are used. Out of the 1065 treatment targets studied, a 5% cutoff criterion cannot always be met for the dose differences between the studied versions of the Gamma Knife Check software and the planning system for 40 treatment targets. © 2016 The Authors.

  18. Two‐year experience with the commercial Gamma Knife Check software

    PubMed Central

    Bhatnagar, Jagdish; Bednarz, Greg; Novotny, Josef; Flickinger, John; Lunsford, L. Dade; Huq, M. Saiful

    2016-01-01

    The Gamma Knife Check software is an FDA approved second check system for dose calculations in Gamma Knife radiosurgery. The purpose of this study was to evaluate the accuracy and the stability of the commercial software package as a tool for independent dose verification. The Gamma Knife Check software version 8.4 was commissioned for a Leksell Gamma Knife Perfexion and a 4C unit at the University of Pittsburgh Medical Center in May 2012. Independent dose verifications were performed using this software for 319 radiosurgery cases on the Perfexion and 283 radiosurgery cases on the 4C units. The cases on each machine were divided into groups according to their diagnoses, and an averaged absolute percent dose difference for each group was calculated. The percentage dose difference for each treatment target was obtained as the relative difference between the Gamma Knife Check dose and the dose from the tissue maximum ratio algorithm (TMR 10) from the GammaPlan software version 10 at the reference point. For treatment plans with imaging skull definition, results obtained from the Gamma Knife Check software using the measurement‐based skull definition method are used for comparison. The collected dose difference data were also analyzed in terms of the distance from the treatment target to the skull, the number of treatment shots used for the target, and the gamma angles of the treatment shots. The averaged percent dose differences between the Gamma Knife Check software and the GammaPlan treatment planning system are 0.3%, 0.89%, 1.24%, 1.09%, 0.83%, 0.55%, 0.33%, and 1.49% for the trigeminal neuralgia, acoustic neuroma, arteriovenous malformation (AVM), meningioma, pituitary adenoma, glioma, functional disorders, and metastasis cases on the Perfexion unit. The corresponding averaged percent dose differences for the 4C unit are 0.33%, 1.2%, 2.78% 1.99%, 1.4%, 1.92%, 0.62%, and 1.51%, respectively. The dose difference is, in general, larger for treatment targets in the peripheral regions of the skull owing to the difference in the numerical methods used for skull shape simulation in the GammaPlan and the Gamma Knife Check software. Larger than 5% dose differences were observed on both machines for certain targets close to patient skull surface and for certain targets in the lower half of the brain on the Perfexion, especially when shots with 70 and/or 110 gamma angles are used. Out of the 1065 treatment targets studied, a 5% cutoff criterion cannot always be met for the dose differences between the studied versions of the Gamma Knife Check software and the planning system for 40 treatment targets. PACS number(s): 87.55.Qr, 87.56.Fc PMID:27455470

  19. Credit WCT. Original 2¾" x 2Y4" color negative is housed ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit WCT. Original 2-¾" x 2-Y4" color negative is housed in the JPL Photography Laboratory, Pasadena, California. View shows JPL staff member John Morrow loading the grinder hopper. The hopper has a 10 mesh screen to filter out particles too large for the mill. Oxidizer is passed steadily to the hammers by a stainless steel feed screw. Oxidizer may be passed through the mill several times depending on the fineness required by a given propellant formula; the maximum charge is 130 pounds (59.0 Kg). The drum below the mill has an electrically conductive plastic liner which receives the ground oxidizer (JPL negative no. JPL10279AC, 27 January 1989) - Jet Propulsion Laboratory Edwards Facility, Oxidizer Grinder Building, Edwards Air Force Base, Boron, Kern County, CA

  20. Monitoring/characterization of stickies contaminants coming from a papermaking plant--Toward an innovative exploitation of the screen rejects to levulinic acid.

    PubMed

    Licursi, Domenico; Antonetti, Claudia; Martinelli, Marco; Ribechini, Erika; Zanaboni, Marco; Raspolli Galletti, Anna Maria

    2016-03-01

    Recycled paper needs a lot of mechanical/chemical treatments for its re-use in the papermaking process. Some of these ones produce considerable rejected waste fractions, such as "screen rejects", which include both cellulose fibers and non-fibrous organic contaminants, or "stickies", these last representing a shortcoming both for the papermaking process and for the quality of the final product. Instead, the accepted fractions coming from these unit operations become progressively poorer in contaminants and richer in cellulose. Here, input and output streams coming from mechanical screening systems of a papermaking plant using recycled paper for cardboard production were sampled and analyzed directly and after solvent extraction, thus confirming the abundant presence of styrene-butadiene rubber (SBR) and ethylene vinyl acetate (EVA) copolymers in the output rejected stream and cellulose in the output accepted one. Despite some significant drawbacks, the "screen reject" fraction could be traditionally used as fuel for energy recovery within the paper mill, in agreement with the integrated recycled paper mill approach. The waste, which still contains a cellulose fraction, can be also exploited by means of the hydrothermal route to give levulinic acid, a platform chemical of very high value added. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. How Sharp Does a "Knife Edge" Have to Be?

    ERIC Educational Resources Information Center

    Dietz, Eric R.; Gash, Philip W.

    1994-01-01

    Describes an experiment designed to help understand the effect of the curvature of the laboratory equipment support (cylindrical rod instead of knife-edge) on the frequency of oscillation of pendula. (ZWH)

  2. Are “knife and fork” good enough for day case surgery of resistant tennis elbow?

    PubMed Central

    Govindaswamy, Raja; Elbouni, Tariq; Chambler, Andrew F. W.

    2008-01-01

    This observational retrospective study was performed on 22 consecutive patients treated surgically in a day surgery unit for resistant tennis elbow to ascertain the effectiveness of the “knife and fork” procedure. All patients had an unfavourable response to nonsurgical treatment lasting at least six months. A simple and inexpensive “knife and fork” technique yielded excellent results in 90.5% of patients and a high percentage (95.2%) of satisfied patients at an average follow-up of two years. There were no fair or poor results and no complications. We conclude that the “knife and fork” technique is a simple and dependable day case procedure. In the present National Health Service (NHS) era of tariff and “payment by results”, this approach is more cost effective than an arthroscopic alternative. PMID:19096844

  3. Interest of submucosal dissection knife for endoscopic treatment of Zenker's diverticulum.

    PubMed

    Laquière, A; Grandval, P; Arpurt, J P; Boulant, J; Belon, S; Aboukheir, S; Laugier, R; Penaranda, G; Curel, L; Boustière, C

    2015-09-01

    Dual-Knife(®) (Olympus) and Hydride-Knife(®) are new needle knives frequently used for submucosal dissection because of their safety and precision. In this study we aimed to evaluate the efficacy and safety of such devices in the diverticulopexy by flexible endoscopy. From February 2009 to March 2013, 42 patients (25 men), mean age 74.5, with symptomatic Zenker's diverticulum, were included in a non-randomized prospective multicenter study. The symptoms described by all patients include dysphagia, regurgitation and/or swallowing disorders. The diverticulopexy was performed with the Dual-Knife(®) or Hydrid-Knife(®), after septum exposure with the diverticuloscope, and terminated with distal tip clips positioning. All complications were noted. Patients' symptoms were regularly assessed during follow-up visits or telephone interviews. The first endoscopy treatment was successful for all patients. Thirty-seven patients (88%) had symptoms improvement after the first treatment. The recurrence rate was 14% (6 patients); a second endoscopic treatment was required 12 months on average after the first treatment, with 100% efficiency. Mid-term (16 months) efficiency was 91.67% after 1 to 3 endoscopic treatments. A total of 55 procedures were performed without perforation or significant bleeding and 3 patients underwent surgery. In multivariate analysis, the diverticulum size and the type of dissection knife were not risks factors for recurrence. Endoscopic diverticuloscope-assisted diverticulotomy with submucosal dissection knives is a safe and effective alternative treatment for patients with a symptomatic Zenker's diverticulum measuring between 2 and 10 cm.

  4. Gamma knife radiosurgery for cerebellopontine angle epidermoid tumors.

    PubMed

    El-Shehaby, Amr M N; Reda, Wael A; Abdel Karim, Khaled M; Emad Eldin, Reem M; Nabeel, Ahmed M

    2017-01-01

    Intracranial epidermoid tumors are commonly found in the cerebellopontine angle where they usually present with either trigeminal neuralgia or hemifacial spasm. Radiosurgery for these tumors has rarely been reported. The purpose of this study is to assess the safety and clinical outcome of the treatment of cerebellopontine epidermoid tumors with gamma knife radiosurgery. This is a retrospective study involving 12 patients harboring cerebellopontine angle epidermoid tumors who underwent 15 sessions of gamma knife radiosurgery. Trigeminal pain was present in 8 patients and hemifacial spasm in 3 patients. All cases with trigeminal pain were receiving medication and still uncontrolled. One patient with hemifacial spasm was medically controlled before gamma knife and the other two were not. Two patients had undergone surgical resection prior to gamma knife treatment. The median prescription dose was 11 Gy (10-11 Gy). The tumor volumes ranged from 3.7 to 23.9 cc (median 10.5 cc). The median radiological follow up was 2 years (1-5 years). All tumors were controlled and one tumor shrank. The median clinical follow-up was 5 years. The trigeminal pain improved or disappeared in 5 patients, and of these, 4 cases stopped their medication and one decreased it. The hemifacial spasm resolved in 2 patients who were able to stop their medication. Facial palsy developed in 1 patient and improved with conservative treatment. Transient diplopia was also reported in 2 cases. Gamma knife radiosurgery provides good clinical control for cerebellopontine angle epidermoid tumors.

  5. Gamma knife radiosurgery for cerebellopontine angle epidermoid tumors

    PubMed Central

    El-Shehaby, Amr M. N.; Reda, Wael A.; Abdel Karim, Khaled M.; Emad Eldin, Reem M.; Nabeel, Ahmed M.

    2017-01-01

    Background: Intracranial epidermoid tumors are commonly found in the cerebellopontine angle where they usually present with either trigeminal neuralgia or hemifacial spasm. Radiosurgery for these tumors has rarely been reported. The purpose of this study is to assess the safety and clinical outcome of the treatment of cerebellopontine epidermoid tumors with gamma knife radiosurgery. Methods: This is a retrospective study involving 12 patients harboring cerebellopontine angle epidermoid tumors who underwent 15 sessions of gamma knife radiosurgery. Trigeminal pain was present in 8 patients and hemifacial spasm in 3 patients. All cases with trigeminal pain were receiving medication and still uncontrolled. One patient with hemifacial spasm was medically controlled before gamma knife and the other two were not. Two patients had undergone surgical resection prior to gamma knife treatment. The median prescription dose was 11 Gy (10–11 Gy). The tumor volumes ranged from 3.7 to 23.9 cc (median 10.5 cc). Results: The median radiological follow up was 2 years (1–5 years). All tumors were controlled and one tumor shrank. The median clinical follow-up was 5 years. The trigeminal pain improved or disappeared in 5 patients, and of these, 4 cases stopped their medication and one decreased it. The hemifacial spasm resolved in 2 patients who were able to stop their medication. Facial palsy developed in 1 patient and improved with conservative treatment. Transient diplopia was also reported in 2 cases. Conclusion: Gamma knife radiosurgery provides good clinical control for cerebellopontine angle epidermoid tumors. PMID:29184709

  6. Inflammatory cytokine expression following the use of bipolar electrocoagulation, ultracision harmonic scalpel and cold knife biopsy.

    PubMed

    Litta, Pietro; Saccardi, Carlo; Gizzo, Salvatore; Conte, Lorena; Ambrosi, Giulia; Sissi, Claudia; Palumbo, Manlio

    2015-08-01

    Electrical surgical devices may determine tissue damage through lateral thermal spread and activation of inflammatory processes. Several tissue effects are associated with the use of different surgical instruments. The aim of the present study was to compare tissue damage following the application of cold knife biopsy, bipolar electrocoagulation and the ultracision harmonic scalpel, through the analysis of inflammatory gene mediator expression. Three fragments of the round ligament (length 0.5 cm) were obtained from 22 females who had undergone total or subtotal laparoscopic hysterectomy using three different modes of resection: Cold knife biopsy, bipolar electrocoagulation and ultracision harmonic scalpel. The tissue fragments were examined by quantitative polymerase chain reaction (qPCR) analysis of selected cytokines. Gene expression analysis demonstrated large standard deviations due to individual variability among patients and indicated variability in the concentrations of cytokines in the three different samples. The quantity of cytokine mRNA in the cold knife biopsy samples was generally greater than those obtained by other techniques. Tumor necrosis factor-α expression was significantly higher in the sample obtained with the ultracision harmonic scalpel and bipolar electrocoagulation (P=0.033) when compared with cold knife biopsy. The inflammatory response was analyzed by the quantification of gene expression through the use of qPCR. The ultracision harmonic scalpel and bipolar electrocoagulation triggered the inflammatory cascade and resulted in an increased production of cytokines compared with cold knife biopsy.

  7. Extracranial Facial Nerve Schwannoma Treated by Hypo-fractionated CyberKnife Radiosurgery.

    PubMed

    Sasaki, Ayaka; Miyazaki, Shinichiro; Hori, Tomokatsu

    2016-09-21

    Facial nerve schwannoma is a rare intracranial tumor. Treatment for this benign tumor has been controversial. Here, we report a case of extracranial facial nerve schwannoma treated successfully by hypo-fractionated CyberKnife (Accuray, Sunnyvale, CA) radiosurgery and discuss the efficacy of this treatment. A 34-year-old female noticed a swelling in her right mastoid process. The lesion enlarged over a seven-month period, and she experienced facial spasm on the right side. She was diagnosed with a facial schwannoma via a magnetic resonance imaging (MRI) scan of the head and neck and was told to wait until the facial nerve palsy subsides. She was referred to our hospital for radiation therapy. We planned a fractionated CyberKnife radiosurgery for three consecutive days. After CyberKnife radiosurgery, the mass in the right parotid gradually decreased in size, and the facial nerve palsy disappeared. At her eight-month follow-up, her facial spasm had completely disappeared. There has been no recurrence and the facial nerve function has been normal. We successfully demonstrated the efficacy of CyberKnife radiosurgery as an alternative treatment that also preserves neurofunction for facial nerve schwannomas.

  8. Bark Separation During Chipping With a Parallel Knife Chipper

    Treesearch

    John R. Erickson

    1968-01-01

    Five winter-cut northern species were chipped in a frozen and unfrozen condition with a parallel knife chipper. The degree of bark separation during chipping and a relative gradation of chip size are reported.

  9. Micro knife-edge optical measurement device in a silicon-on-insulator substrate.

    PubMed

    Chiu, Yi; Pan, Jiun-Hung

    2007-05-14

    The knife-edge method is a commonly used technique to characterize the optical profiles of laser beams or focused spots. In this paper, we present a micro knife-edge scanner fabricated in a silicon-on-insulator substrate using the micro-electromechanical-system technology. A photo detector can be fabricated in the device to allow further integration with on-chip signal conditioning circuitry. A novel backside deep reactive ion etching process is proposed to solve the residual stress effect due to the buried oxide layer. Focused optical spot profile measurement is demonstrated.

  10. Patient-Reported Quality of Life Progression in Men with Prostate Cancer following Primary Cryotherapy, Cyberknife, or Active Holistic Surveillance

    PubMed Central

    Werneburg, Glenn T.; Kongnyuy, Michael; Halpern, Daniel M.; Salcedo, Jose M.; Kosinski, Kaitlin E.; Haas, Jonathan A.; Schiff, Jeffrey T.; Corcoran, Anthony T.; Katz, Aaron E.

    2017-01-01

    Background Technological advancements have led to the success of minimally invasive treatment modalities for prostate cancer such as CyberKnife and Cryotherapy. Here, we investigate patient-reported urinary function, bowel habits, and sexual function in patients following CyberKnife (CK) or Cryotherapy treatment, and compare them with active holistic surveillance (AHS) patients. Methods An IRB-approved institutional database was retrospectively reviewed for patients who underwent CK, Cryotherapy, or AHS. Quality of life (QoL) survey responses were collected every three months and the mean function scores were analyzed in yearly intervals over the 4 years post-treatment. Results 279 patients (767 survey sets) were included in the study. There was no difference among groups in urinary function scores. The CyberKnife group had significantly lower bowel habit scores in the early years following treatment (year two mean difference: −5.4, p<0.01) but returned to AHS level scores by year four. Cryotherapy patients exhibited initially lower, but not statistically significant, bowel function scores, which then improved and approached those of AHS. Both CyberKnife (year 1 mean difference: −26.7, p<0.001) and Cryotherapy groups (−35.4, p<0.001) had early lower sexual function scores relative to AHS, but then gradually improved and were not significantly different from AHS by the third year post-treatment. A history of hormonal therapy was associated with a lower sexual function scores relative to those patients who did not receive hormones in both CyberKnife (−18.45, p<0.01) and Cryotherapy patients (−14.6, p<0.05). Conclusions After initially lower bowel habits and sexual function scores, CyberKnife or Cryotherapy-treated patients had no significant difference in QoL relative to AHS patients. These results highlight the benefit of CyberKnife and Cryotherapy in the management of organ-confined prostate cancer. PMID:29217830

  11. Process parameter dependent growth phenomena of naproxen nanosuspension manufactured by wet media milling.

    PubMed

    Bitterlich, A; Laabs, C; Krautstrunk, I; Dengler, M; Juhnke, M; Grandeury, A; Bunjes, H; Kwade, A

    2015-05-01

    The production of nanosuspensions has proved to be an effective method for overcoming bioavailability challenges of poorly water soluble drugs. Wet milling in stirred media mills and planetary ball mills has become an established top-down-method for producing such drug nanosuspensions. The quality of the resulting nanosuspension is determined by the stability against agglomeration on the one hand, and the process parameters of the mill on the other hand. In order to understand the occurring dependencies, a detailed screening study, not only on adequate stabilizers, but also on their optimum concentration was carried out for the active pharmaceutical ingredient (API) naproxen in a planetary ball mill. The type and concentration of the stabilizer had a pronounced influence on the minimum particle size obtained. With the best formulation the influence of the relevant process parameters on product quality was investigated to determine the grinding limit of naproxen. Besides the well known phenomenon of particle agglomeration, actual naproxen crystal growth and morphology alterations occurred during the process which has not been observed before. It was shown that, by adjusting the process parameters, those effects could be reduced or eliminated. Thus, besides real grinding and agglomeration a process parameter dependent ripening of the naproxen particles was identified to be a concurrent effect during the naproxen fine grinding process. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. 7 CFR 868.312 - Grade and grade requirements for the class Screenings Milled Rice. (See also § 868.315.)

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... grams) Objectionable seeds (number in 500 grams) Chalky kernels 1,3 (percent) Color requirements 1...) has any commercially objectionable foreign odor; (e) has a badly damaged or extremely red appearance...

  13. A sharp knife for high temperatures

    NASA Technical Reports Server (NTRS)

    Heisman, R. M.; Iceland, W. F.

    1978-01-01

    Electrically heated nickel-chrome-steel alloy knife may be used to cut heat resistant plastic felt and similar materials with relative ease. Blade made of commercially available alloy RA 330 retains edge at temperatures as high as 927 C.

  14. Knife-edge seal for vacuum bagging

    NASA Technical Reports Server (NTRS)

    Rauschl, J. A.

    1980-01-01

    Cam actuated clamps pinch bagging material between long knife edge (mounted to clamps) and high temperature rubber cushion bonded to baseplate. No adhesive, tape, or sealing groove is needed to seal edge of bagging sheet against base plate.

  15. Blurred image restoration using knife-edge function and optimal window Wiener filtering.

    PubMed

    Wang, Min; Zhou, Shudao; Yan, Wei

    2018-01-01

    Motion blur in images is usually modeled as the convolution of a point spread function (PSF) and the original image represented as pixel intensities. The knife-edge function can be used to model various types of motion-blurs, and hence it allows for the construction of a PSF and accurate estimation of the degradation function without knowledge of the specific degradation model. This paper addresses the problem of image restoration using a knife-edge function and optimal window Wiener filtering. In the proposed method, we first calculate the motion-blur parameters and construct the optimal window. Then, we use the detected knife-edge function to obtain the system degradation function. Finally, we perform Wiener filtering to obtain the restored image. Experiments show that the restored image has improved resolution and contrast parameters with clear details and no discernible ringing effects.

  16. Blurred image restoration using knife-edge function and optimal window Wiener filtering

    PubMed Central

    Zhou, Shudao; Yan, Wei

    2018-01-01

    Motion blur in images is usually modeled as the convolution of a point spread function (PSF) and the original image represented as pixel intensities. The knife-edge function can be used to model various types of motion-blurs, and hence it allows for the construction of a PSF and accurate estimation of the degradation function without knowledge of the specific degradation model. This paper addresses the problem of image restoration using a knife-edge function and optimal window Wiener filtering. In the proposed method, we first calculate the motion-blur parameters and construct the optimal window. Then, we use the detected knife-edge function to obtain the system degradation function. Finally, we perform Wiener filtering to obtain the restored image. Experiments show that the restored image has improved resolution and contrast parameters with clear details and no discernible ringing effects. PMID:29377950

  17. Acute necrosis after Gamma Knife surgery in vestibular schwannoma leading to multiple cranial nerve palsies.

    PubMed

    Kapitza, Sandra; Pangalu, Athina; Horstmann, Gerhard A; van Eck, Albert T; Regli, Luca; Tarnutzer, Alexander A

    2016-08-01

    We discuss a rare acute complication after Gamma Knife therapy (Elekta AB, Stockholm, Sweden) in a single patient. A 52-year-old woman presented with vertigo, facial weakness and hearing loss emerging 48hours following Gamma Knife radiosurgery for a right-sided vestibular schwannoma. Neurological examination 6days after symptom onset showed right-sided facial palsy, spontaneous left-beating nystagmus and pathologic head-impulse testing to the right. Pure-tone audiogram revealed right-sided sensorineural hearing loss. A diagnosis of acute vestibulocochlear and facial neuropathy was made. Brain MRI demonstrated focal contrast sparing within the schwannoma, likely related to acute radiation necrosis. Acute multiple cranial neuropathies of the cerebellopontine angle after Gamma Knife treatment should raise suspicion of acute tissue damage within the schwannoma and should result in urgent MRI. Treatment with steroids may be considered based on accompanying swelling and edema. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Stereotaxic gamma knife surgery in treatment of critically located pilocytic astrocytoma: preliminary result

    PubMed Central

    Hafez, Raef FA

    2007-01-01

    Background Low-grade gliomas are uncommon primary brain tumors, located more often in the posterior fossa, optic pathway, and brain stem and less commonly in the cerebral hemispheres. Case presentations Two patients with diagnosed recurrent cystic pilocytic astrocytoma critically located within the brain (thalamic and brain stem) were treated with gamma knife surgery. Gamma knife surgery (GKS) did improve the patient's clinical condition very much which remained stable later on. Progressive reduction on the magnetic resonance imaging (MRI) studies of the solid part of the tumor and almost disappearance of the cystic component was achieved within the follow-up period of 36 months in the first case with the (thalamic located lesion) and 22 months in the second case with the (brain stem located lesion). Conclusion Gamma knife surgery represents an alternate tool in the treatment of recurrent and/or small postoperative residual pilocytic astrocytoma especially if they are critically located PMID:17394660

  19. Methods of amorphization and investigation of the amorphous state.

    PubMed

    Einfal, Tomaž; Planinšek, Odon; Hrovat, Klemen

    2013-09-01

    The amorphous form of pharmaceutical materials represents the most energetic solid state of a material. It provides advantages in terms of dissolution rate and bioavailability. This review presents the methods of solid- -state amorphization described in literature (supercooling of liquids, milling, lyophilization, spray drying, dehydration of crystalline hydrates), with the emphasis on milling. Furthermore, we describe how amorphous state of pharmaceuticals differ depending on the method of preparation and how these differences can be screened by a variety of spectroscopic (X-ray powder diffraction, solid state nuclear magnetic resonance, atomic pairwise distribution, infrared spectroscopy, terahertz spectroscopy) and calorimetry methods.

  20. A microcosting study of microsurgery, LINAC radiosurgery, and gamma knife radiosurgery in meningioma patients

    PubMed Central

    van Putten, Erik; Nijdam, Wideke M.; Hanssens, Patrick; Beute, Guus N.; Nowak, Peter J.; Dirven, Clemens M.; Hakkaart-van Roijen, Leona

    2010-01-01

    The aim of the present study is to determine and compare initial treatment costs of microsurgery, linear accelerator (LINAC) radiosurgery, and gamma knife radiosurgery in meningioma patients. Additionally, the follow-up costs in the first year after initial treatment were assessed. Cost analyses were performed at two neurosurgical departments in The Netherlands from the healthcare providers’ perspective. A total of 59 patients were included, of whom 18 underwent microsurgery, 15 underwent LINAC radiosurgery, and 26 underwent gamma knife radiosurgery. A standardized microcosting methodology was employed to ensure that the identified cost differences would reflect only actual cost differences. Initial treatment costs, using equipment costs per fraction, were €12,288 for microsurgery, €1,547 for LINAC radiosurgery, and €2,412 for gamma knife radiosurgery. Higher initial treatment costs for microsurgery were predominantly due to inpatient stay (€5,321) and indirect costs (€4,350). LINAC and gamma knife radiosurgery were equally expensive when equipment was valued per treatment (€2,198 and €2,412, respectively). Follow-up costs were slightly, but not significantly, higher for microsurgery compared with LINAC and gamma knife radiosurgery. Even though initial treatment costs were over five times higher for microsurgery compared with both radiosurgical treatments, our study gives indications that the relative cost difference may decrease when follow-up costs occurring during the first year after initial treatment are incorporated. This reinforces the need to consider follow-up costs after initial treatment when examining the relative costs of alternative treatments. PMID:20526795

  1. World Health Organization Guidelines for treatment of cervical intraepithelial neoplasia 2-3 and screen-and-treat strategies to prevent cervical cancer.

    PubMed

    Santesso, Nancy; Mustafa, Reem A; Schünemann, Holger J; Arbyn, Marc; Blumenthal, Paul D; Cain, Joanna; Chirenje, Michael; Denny, Lynette; De Vuyst, Hugo; Eckert, Linda O'Neal; Forhan, Sara E; Franco, Eduardo L; Gage, Julia C; Garcia, Francisco; Herrero, Rolando; Jeronimo, José; Lu, Enriquito R; Luciani, Silvana; Quek, Swee Chong; Sankaranarayanan, Rengaswamy; Tsu, Vivien; Broutet, Nathalie

    2016-03-01

    It is estimated that 1%-2% of women develop cervical intraepithelial neoplasia grade 2-3 (CIN 2-3) annually worldwide. The prevalence among women living with HIV is higher, at 10%. If left untreated, CIN 2-3 can progress to cervical cancer. WHO has previously published guidelines for strategies to screen and treat precancerous cervical lesions and for treatment of histologically confirmed CIN 2-3. Guidelines were developed using the WHO Handbook for Guideline Development and the GRADE (Grading of Recommendations, Assessment, Development and Evaluation) approach. A multidisciplinary guideline panel was created. Systematic reviews of randomized controlled trials and observational studies were conducted. Evidence tables and Evidence to Recommendations Tables were prepared and presented to the panel. There are nine recommendations for screen-and-treat strategies to prevent cervical cancer, including the HPV test, cytology, and visual inspection with acetic acid. There are seven for treatment of CIN with cryotherapy, loop electrosurgical excision procedure, and cold knife conization. Recommendations have been produced on the basis of the best available evidence. However, high-quality evidence was not available. Such evidence is needed, in particular for screen-and-treat strategies that are relevant to low- and middle-income countries. Copyright © 2015. Published by Elsevier Ireland Ltd.

  2. Splash M-knife versus Flush Knife BT in the technical outcomes of endoscopic submucosal dissection for early gastric cancer: a propensity score matching analysis.

    PubMed

    Esaki, Mitsuru; Suzuki, Sho; Hayashi, Yasuyo; Yokoyama, Azusa; Abe, Shuichi; Hosokawa, Taizo; Ogino, Haruei; Akiho, Hirotada; Ihara, Eikichi; Ogawa, Yoshihiro

    2018-02-27

    Endoscopic submucosal dissection (ESD) is a standard treatment for early gastric cancer. A new multi-functional ESD device was developed to achieve complete ESD with a single device. A metal plate attached to its distal sheath achieves better hemostasis during the procedure than the other needle-knife device, Flush Knife BT®, that has been conventionally used. The aim of this study was to compare the technical outcomes of ESD for early gastric cancer using the Splash M-Knife® with those using the Flush Knife BT. We conducted a retrospective review of the case records of 149 patients with early gastric cancer treated with ESD using the needle-type ESD knives between January 2012 and August 2016 at Kitakyushu Municipal Medical Center. Lesions treated with ESD using the Splash M-knife (ESD-M) and the Flush Knife BT (ESD-F) were compared. Multivariate analyses and propensity score matching were used to compensate for the differences in age, gender, underlying disease, antithrombotic drug use, lesion location, lesion position, macroscopic type, tumor size, presence of ulceration, operator level and types of electrosurgical unit used. The primary endpoint was the requirement to use hemostatic forceps in the two groups. The secondary endpoints of procedure time, en bloc and complete resection rates, and adverse events rates were evaluated for the two groups. There were 73 patients in the ESD-M group, and 76 patients in the ESD-F group. Propensity score matching analysis created 45 matched pairs. Adjusted comparisons between the two groups showed a significantly lower usage rate of hemostatic forceps in the ESD-M group than in the ESD-F group (6.7% vs 84.4%, p < 0.001). Treatment outcomes showed an en bloc resection rate of 100% in both groups; complete resection rate of 95.6% vs 100%, p = 0.49; median procedure time of 74.0 min vs 71.0 min, p = 0.90; post-procedure bleeding of 2.2% vs 2.2%, p = 1, in the ESD-M and ESD-F groups, respectively. There were no perforations in either group. ESD-M appeared to reduce the usage of hemostatic forceps during ESD for early gastric cancer without increasing the adverse effects. Thus, it may contribute to a reduction in the total ESD cost.

  3. The "Knife-Cut Sign" Revisited: A Distinctive Presentation of Linear Erosive Herpes Simplex Virus Infection in Immunocompromised Patients.

    PubMed

    Cohen, Philip R

    2015-10-01

    The "knife-cut sign" is a distinctive presentation of linear erosive herpes simplex virus infection in immunocompromised patients. To describe a man whose herpes simplex virus infection-related skin lesions demonstrated the "knife-cut sign" and to review the characteristics of reported immunosuppressed individuals with "knife-cut" cutaneous herpes simplex virus lesions. A man with multiple myeloma and post-stem cell transplant cutaneous graft-versus-host disease managed with systemic prednisone and sirolimus developed disseminated cutaneous herpes simplex virus infection with virus-associated linear ulcers of the inguinal folds and the area between his ear and scalp; the lesions at both sites had a distinctive "knife-cut" appearance. Using the PubMed database, an extensive literature search was performed on herpes simplex virus, immunocompromised patient, and "knife-cut sign". Herpes simplex virus infection-associated skin lesions that demonstrate the "knife-cut sign" present in patients who are immunosuppressed secondary to either an underlying medical condition or a systemic therapy or both. The distinctive virus-related cutaneous lesions appear as linear ulcers and fissures in intertriginous areas, such as the folds in the inguinal area, the vulva, and the abdomen; in addition, other sites include beneath the breast, within the gluteal cleft, and the area between the ear and the scalp. Not only herpes simplex virus-2, but also herpes simplex virus-1 has been observed as the causative viral serotype; indeed, herpes simplex virus-1 has been associated with genital and inframammary lesions in addition to those above the neck. Direct fluorescent antibody testing is a rapid method for confirming the clinically suspected viral infection; however, since false-negative direct fluorescent antibody testing occurred in some of the patients, it may be prudent to also perform viral cultures and possibly lesional skin biopsies to establish the diagnosis. The herpes simplex virus infection-related skin lesions clinically improve once systemic antiviral therapy is initiated. In immunosuppressed individuals, the "knife-cut sign" is a distinctive presentation of cutaneous linear erosive herpes simplex virus infection. Recognition of the linear ulcers in intertriginous areas and body folds should prompt the clinician to consider herpes simplex virus infection-associated skin lesions in an immunocompromised patient and to initiate systemic antiviral treatment while awaiting the results of laboratory evaluation to confirm the suspected diagnosis.

  4. Systematic reviews and meta-analyses of benefits and harms of cryotherapy, LEEP, and cold knife conization to treat cervical intraepithelial neoplasia.

    PubMed

    Santesso, Nancy; Mustafa, Reem A; Wiercioch, Wojtek; Kehar, Rohan; Gandhi, Shreyas; Chen, Yaolong; Cheung, Adrienne; Hopkins, Jessica; Khatib, Rasha; Ma, Bin; Mustafa, Ahmad A; Lloyd, Nancy; Wu, Darong; Broutet, Nathalie; Schünemann, Holger J

    2016-03-01

    Cervical intraepithelial neoplasia (CIN) stage 2-3 is a premalignant lesion that can progress to cervical cancer in 10-20 years if untreated. To conduct systematic reviews of randomized and nonrandomized studies for effects of cryotherapy, loop electrosurgical excision procedure (LEEP), and cold knife conization (CKC) as treatment for CIN 2-3. Medline, Embase, and other databases were searched to February 2012 for benefits, and to July 2012 for harms. Additionally, experts were contacted. Keywords for CIN, cervical cancer, and the treatments were used. Studies of nonpregnant women 18 years or older not previously treated for CIN were included. Two investigators independently screened and collected data. Relative risks and proportions were calculated and evidence assessed using GRADE (Grading of Recommendations Assessment, Development and Evaluation). Recurrence rate was 5.3% 12 months after cryotherapy or LEEP, and 1.4% after CKC. There seemed to be little or no differences in frequency of complications after LEEP or cryotherapy, but they occurred more often after CKC. Evidence suggests premature delivery is most common with CKC, but it also occurs after LEEP and cryotherapy. Despite a comprehensive search, there is very low quality evidence and often no evidence for important outcomes, including reproductive outcomes and complications. Studies assessing these outcomes are needed. Copyright © 2015 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  5. Gauge Measures Thicknesses Of Blankets

    NASA Technical Reports Server (NTRS)

    Hagen, George R.; Yoshino, Stanley Y.

    1991-01-01

    Tool makes highly repeatable measurements of thickness of penetrable blanket insulation. Includes commercial holder for replaceable knife blades, which holds needle instead of knife. Needle penetrates blanket to establish reference plane. Ballasted slider applies fixed preload to blanket. Technician reads thickness value on scale.

  6. Non-reclosing pressure relief device for vacuum systems

    DOEpatents

    Swansiger, William A.

    1994-01-01

    A non-reclosing overpressure protection device such as a rupture disc provides a non-reclosing opening upon forcible contact with a knife blade. A bellows, having an inlet capable of being sealably connected to a source of pressure (the vacuum system) and an outlet containing the rupture disc, transmits the pressure in the system to the disc. The bellows maintains the disc away from the knife when the pressure is below an overpressure amount, and carries the disc to a position when the pressure is above an overpressure amount where the disc is ruptured by the knife.

  7. Non-reclosing pressure relief device for vacuum systems

    DOEpatents

    Swansiger, W.A.

    1994-02-08

    A non-reclosing overpressure protection device such as a rupture disc provides a non-reclosing opening upon forcible contact with a knife blade. A bellows, having an inlet capable of being sealably connected to a source of pressure (the vacuum system) and an outlet containing the rupture disc, transmits the pressure in the system to the disc. The bellows maintains the disc away from the knife when the pressure is below an overpressure amount, and carries the disc to a position when the pressure is above an overpressure amount where the disc is ruptured by the knife. 6 figures.

  8. [Preparation and Performance of Ultrafast γ-CuI Scintillation Conversion Screen].

    PubMed

    Xia, Ming; Gu, Mu; Liu, Xiao-lin; Liu, Bo; Huang, Shi-ming; Ni, Chen

    2015-04-01

    Micro-columnar structured γ-CuI scintillation conversion screen with columnar diameter in the micrometer and thickness about 17 µm were prepared by thermal evaporation method on quartz substrates with different temperatures. X-ray excited luminescence spectra of the screens show two peaks located at 430 nm and near 700 nm, which correspond to the fast and slow emission components, respectively. The fast one dominated. The intensity of 430 nm peak decreased as the substrate temperature rose from 170 °C to 210 °C. At the same time the intensity of 700 nm band increased. The changes may be attributed to the iodine loss from screen caused by the substrate temperature. The phenomenon of iodine loss was observed by the Rutherford backscattering experiment. The crystal structure of the screens presents (111) preferred orientation, which is independent of the substrate temperature. As the temperature rose to 210 °C, two weak additional peaks of (220) and (420) γ-CuI crystal planes in X-ray diffraction patterns appeared due to the increase in kinetic energy of CuI molecules. The scanning electron microscopy images of the screens showed that the columnar structure was improved when the substrate temperature increased from 170 °C to 190 °C, but it would be degenerated when the temperature continued to rise to 210 °C because of the surface and bulk diffusion effects of the depositing molecules. Finally, the spatial resolution of the γ-CuI scintillation screens was measured by knife-edge method, and they are 4.5, 7.2 and 5.6lp · mm(-1) for the screens prepared at the substrates temperatures of 170, 190 and 210 °C, respectively. The result shows that micro-column structure could improve the spatial resolution of γ-CuI scintillation screen.

  9. Review of the poster "Dosimetric comparison of gamma knife radiosurgery vs. 125I plaque brachytherapy in a cohort of choroidal melanomas".

    PubMed

    Odell, Kelly R

    2009-01-01

    Historically, treatment for choroidal melanomas was surgical enucleation. Currently, treatment methods such as stereotactic radiosurgery and brachytherapy are being used to spare the eye. The poster "Dosimetric Comparison of Gamma Knife Radiosurgery vs. I-125 Plaque Brachytherapy in a Cohort of Choroidal Melanomas" presented at ASTRO 2007 by Anderson et al. provides a comparison of these methods. The dose to disk, fovea and lens in 29 patients from a simulated I-125 treatment and a delivered Gamma Knife radiosurgery was compared. Thirty Gy was prescribed to the 50% Isodose line in the radiosurgery and 85 Gy was prescribed to the apex of the tumor in the I-125 simulation. It was found that the Gamma Knife spares the disk better in 59% of the tumors, including those >or=6.5 mm in height; spares the fovea better in 69% of the tumors, including those >or=5.5 mm; and spares lens better in only 30% of the tumors, with no distinction in size. Tumor location was not taken into account for this study, which could explain the variations in smaller tumors. For larger tumors, gamma knife will protect most organs at risk more effectively. This study shows how a tumor's parameters can be used in selecting treatment modality.

  10. Heuristic estimation of electromagnetically tracked catheter shape for image-guided vascular procedures

    NASA Astrophysics Data System (ADS)

    Mefleh, Fuad N.; Baker, G. Hamilton; Kwartowitz, David M.

    2014-03-01

    In our previous work we presented a novel image-guided surgery (IGS) system, Kit for Navigation by Image Focused Exploration (KNIFE).1,2 KNIFE has been demonstrated to be effective in guiding mock clinical procedures with the tip of an electromagnetically tracked catheter overlaid onto a pre-captured bi-plane fluoroscopic loop. Representation of the catheter in KNIFE differs greatly from what is captured by the fluoroscope, due to distortions and other properties of fluoroscopic images. When imaged by a fluoroscope, catheters can be visualized due to the inclusion of radiopaque materials (i.e. Bi, Ba, W) in the polymer blend.3 However, in KNIFE catheter location is determined using a single tracking seed located in the catheter tip that is represented as a single point overlaid on pre-captured fluoroscopic images. To bridge the gap in catheter representation between KNIFE and traditional methods we constructed a catheter with five tracking seeds positioned along the distal 70 mm of the catheter. We have currently investigated the use of four spline interpolation methods for estimation of true catheter shape and have assesed the error in their estimation of true catheter shape. In this work we present a method for the evaluation of interpolation algorithms with respect to catheter shape determination.

  11. Carbon dioxide laser fiber for the excision of oral leukoplakia.

    PubMed

    Chee, Michael; Sasaki, Clarence

    2013-09-01

    We compared the efficacies of cold knife excision and carbon dioxide (CO2) laser fiber excision of oral cavity leukoplakia. Between August 2009 and June 2011,45 patients who underwent excision of oral cavity leukoplakia were assessed for operative time, use of bipolar cautery, blood loss, and number of intraoperative margins needed. Patients were assigned randomly to either a cold knife group (23 procedures) or a CO2 laser fiber group (24 procedures) at the time of the procedure. The times of excision were similar in the CO2 laser fiber group (1.64 min/cm2) and the cold knife group (1.70 min/cm2). There were large differences between the CO2 laser fiber group and the cold knife group in the categories of bipolar cautery uses per square centimeter (0.34 uses versus 3.32 uses) and blood loss (0.19 g/cm2 versus 2.55 g/cm2). The average number of margins needed to clear a specimen by frozen section was 1.21 for the CO2 laser fiber group and 1.83 for the cold knife group. The CO2 laser fiber did not show an advantage in operative time. The CO2 laser fiber did show better outcomes in the areas of blood loss, bipolar cautery use, and intraoperative margins needed.

  12. Safety and efficacy of endoscopic submucosal dissection using IT knife nano with clip traction method for early esophageal squamous cell carcinoma.

    PubMed

    Kitagawa, Yoshiyasu; Suzuki, Takuto; Hara, Taro; Yamaguchi, Taketo

    2018-01-01

    Although endoscopic submucosal dissection (ESD) is an accepted and established treatment for early esophageal squamous cell carcinoma (EESCC), it is technically difficult, time consuming, and less safe than endoscopic mucosal resection. To perform ESD safely and more efficiently, we proposed a new technique of esophageal ESD using an IT knife nano with the clip traction method. This study aimed to evaluate the efficacy and safety of ESD using this new technique. We retrospectively reviewed all consecutive cases of esophageal ESD performed using an IT knife nano with the clip traction method at our hospital between March 2013 and January 2017. Therapeutic efficacy and safety were also assessed. A total of 103 patients underwent esophageal ESD using the IT knife nano with the clip traction method. In all cases, we performed en bloc resection. Complete resection was achieved in 100 cases (97.1%). The median operating time was 40 (range 13-230) min. No cases of perforation or delayed bleeding occurred. Although two cases (2.0%) of mediastinal emphysema occurred without visible perforation at endoscopy, all were successfully managed conservatively. The new technique of esophageal ESD using the IT knife nano with the clip traction method appears to be feasible, effective, and safe for EESCC treatment.

  13. Comparison of conventional versus Hybrid knife peroral endoscopic myotomy methods for esophageal achalasia: a case-control study.

    PubMed

    Tang, Xiaowei; Gong, Wei; Deng, Zhiliang; Zhou, Jieqiong; Ren, Yutang; Zhang, Qiang; Chen, Zhenyu; Jiang, Bo

    2016-01-01

    Peroral endoscopic myotomy (POEM) has been developed to treat achalasia as a novel less invasive modality. We aimed to compare the efficacy and safety of conventional knife versus Hybrid knife (HK) during POEM procedure. Between June 2012 and July 2014, 31 patients underwent POEM using HK in our department (HK group), and 36 patients underwent POEM using conventional method (injection needle and triangular tip [TT] knife, TT group). Procedure-related parameters, symptom relief, adverse events were compared between two groups. There were no significant differences in the age, sex and other baseline characteristics between the two groups. The mean procedural time was significantly shorter in HK group than TT group (53.0 ± 17.2 vs. 67.6 ± 28.4 min, p = 0.015). The mean frequency of devices exchange was 4.7 ± 1.7 in HK group and 10.9 ± 1.8 in TT group (p = 0.000). No serious adverse events occurred postoperatively in both groups. At one-year follow-up, a total of 94% treatment success was achieved in all patients (93.5% in HK group and 94.4% in TT group, p = 0.877). HK in POEM can shorten the procedural time, and achieve similar treatment success compared to conventional TT knife.

  14. The Critical Compression Load for a Universal Testing Machine When the Specimen Is Loaded Through Knife Edges

    NASA Technical Reports Server (NTRS)

    Lundquist, Eugene E; Schwartz, Edward B

    1942-01-01

    The results of a theoretical and experimental investigation to determine the critical compression load for a universal testing machine are presented for specimens loaded through knife edges. The critical load for the testing machine is the load at which one of the loading heads becomes laterally instable in relation to the other. For very short specimens the critical load was found to be less than the rated capacity given by the manufacturer for the machine. A load-length diagram is proposed for defining the safe limits of the test region for the machine. Although this report is particularly concerned with a universal testing machine of a certain type, the basic theory which led to the derivation of the general equation for the critical load, P (sub cr) = alpha L can be applied to any testing machine operated in compression where the specimen is loaded through knife edges. In this equation, L is the length of the specimen between knife edges and alpha is the force necessary to displace the upper end of the specimen unit horizontal distance relative to the lower end of the specimen in a direction normal to the knife edges through which the specimen is loaded.

  15. The SKED: speckle knife edge detector

    NASA Astrophysics Data System (ADS)

    Sharpies, S. D.; Light, R. A.; Achamfuo-Yeboah, S. O.; Clark, M.; Somekh, M. G.

    2014-06-01

    The knife edge detector—also known as optical beam deflection—is a simple and robust method of detecting ultrasonic waves using a laser. It is particularly suitable for detection of high frequency surface acoustic waves as the response is proportional to variation of the local tilt of the surface. In the case of a specular reflection of the incident laser beam from a smooth surface, any lateral movement of the reflected beam caused by the ultrasonic waves is easily detected by a pair of photodiodes. The major disadvantage of the knife edge detector is that it does not cope well with optically rough surfaces, those that give a speckled reflection. The optical speckles from a rough surface adversely affect the efficiency of the knife edge detector, because 'dark' speckles move synchronously with 'bright' speckles, and their contributions to the ultrasonic signal cancel each other out. We have developed a new self-adapting sensor which can cope with the optical speckles reflected from a rough surface. It is inelegantly called the SKED—speckle knife edge detector—and like its smooth surface namesake it is simple, cheap, compact, and robust. We describe the theory of its operation, and present preliminary experimental results validating the overall concept and the operation of the prototype device.

  16. 43. INTERIOR VIEW, CRUSHING ADDITION. THE SYMONS VIBRATING SCREEN SITS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    43. INTERIOR VIEW, CRUSHING ADDITION. THE SYMONS VIBRATING SCREEN SITS ON TOP OF THE PLATFORM. OVERSIZE ORE IS FED BY CHUTE TO THE GYRATORY SECONDARY CRUSHER (MISSING) SITTING ON CONCRETE FOUNDATIONS TO LOWER RIGHT. UNDERSIZE ORE WAS FED BY THE LOWER CHUTE (CENTER LEFT) TO THE 24 INCH BELT CONVEYOR UNDER THE SECONDARY CRUSHER. THE DRYER ROOM IS BEYOND. - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD

  17. Impact of process conditions on the density and durability of wheat, oat, canola, and barley straw briquettes

    DOE PAGES

    Tumuluru, J. S.; Tabil, L. G.; Song, Y.; ...

    2014-10-01

    The present study is to understand the impact of process conditions on the quality attributes of wheat oat, barley, and canola straw briquettes. Analysis of variance indicated that briquette moisture content and initial density immediately after compaction and final density after 2 weeks of storage are strong functions of feedstock moisture content and compression pressure, whereas durability rating is influenced by die temperature and feedstock moisture content. Briquettes produced at a low feedstock moisture content of 9 % (w.b.) yielded maximum densities >700 kg/m3 for wheat, oat, canola, and barley straws. Lower feedstock moisture content of <10 % (w.b.) andmore » higher die temperatures >110 °C and compression pressure >10 MPa minimized the briquette moisture content and maximized densities and durability rating based on surface plots observations. Optimal process conditions indicated that a low feedstock moisture content of about 9 % (w.b.), high die temperature of 120–130 °C, medium-to-large hammer mill screen sizes of about 24 to 31.75 mm, and low to high compression pressures of 7.5 to 12.5 MPa minimized briquette moisture content to <8 % (w.b.) and maximized density to >700 kg/m3. Durability rating >90 % is achievable at higher die temperatures of >123 °C, lower to medium feedstock moisture contents of 9 to 12 % (w.b.), low to high compression pressures of 7.5 to 12.5 MPa, and large hammer mill screen size of 31.75 mm, except for canola where a lower compression pressure of 7.5 to 8.5 MPa and a smaller hammer mill screen size of 19 mm for oat maximized the durability rating values.« less

  18. Correction of measured Gamma-Knife output factors for angular dependence of diode detectors and PinPoint ionization chamber.

    PubMed

    Hršak, Hrvoje; Majer, Marija; Grego, Timor; Bibić, Juraj; Heinrich, Zdravko

    2014-12-01

    Dosimetry for Gamma-Knife requires detectors with high spatial resolution and minimal angular dependence of response. Angular dependence and end effect time for p-type silicon detectors (PTW Diode P and Diode E) and PTW PinPoint ionization chamber were measured with Gamma-Knife beams. Weighted angular dependence correction factors were calculated for each detector. The Gamma-Knife output factors were corrected for angular dependence and end effect time. For Gamma-Knife beams angle range of 84°-54°. Diode P shows considerable angular dependence of 9% and 8% for the 18 mm and 14, 8, 4 mm collimator, respectively. For Diode E this dependence is about 4% for all collimators. PinPoint ionization chamber shows angular dependence of less than 3% for 18, 14 and 8 mm helmet and 10% for 4 mm collimator due to volumetric averaging effect in a small photon beam. Corrected output factors for 14 mm helmet are in very good agreement (within ±0.3%) with published data and values recommended by vendor (Elekta AB, Stockholm, Sweden). For the 8 mm collimator diodes are still in good agreement with recommended values (within ±0.6%), while PinPoint gives 3% less value. For the 4 mm helmet Diodes P and E show over-response of 2.8% and 1.8%, respectively. For PinPoint chamber output factor of 4 mm collimator is 25% lower than Elekta value which is generally not consequence of angular dependence, but of volumetric averaging effect and lack of lateral electronic equilibrium. Diodes P and E represent good choice for Gamma-Knife dosimetry. Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  19. Endoscopic treatment of Zenker's diverticulum with the stag beetle knife (sb knife) - feasibility and follow-up.

    PubMed

    Goelder, S K; Brueckner, J; Messmann, H

    2016-10-01

    Flexible endoscopic treatment of symptomatic Zenker's diverticulum (ZD) is an established treatment option. This study reports the first large cohort of ZD patients treated with the stag beetle knife (sb knife, a new scissor-like device) regarding feasibility, safety, and sustainability of mucomyotomy using this technique. From August 2013 to January 2016, n = 52 patients (pts) were treated at Klinikum Augsburg, a tertiary referral center, with the sb knife junior or standard. For stability and safety, the septum is fixed with a soft overtube before intervention. Symptoms were analyzed before and at 1 and 6 months past intervention using an extensive questionnaire of dysphagia, odynophagia, regurgitation, chronic cough, state of health, and complications. The mean size of ZD was 3 cm (1-5 cm). Forty-seven out of 52 (90.4%) patients received one treatment session. The mean procedure time was 32 min (18-60 min). In 10 procedures (17%), a clip was placed at the bottom of the resection line. No major complications (e.g., perforation, mediastinitis) occurred. Five patients (9.6%) required a second treatment after a mean of 7 months (3-13) due to symptomatic recurrence. One patient was lost to further follow-up after one month with no or rare complaints. One patient had a third treatment (1.9%) without complications. During a mean follow-up of 16 months (2-31), the dysphagia score improved from 2 (1-4) prior of treatment to 1 (0-4), odynophagia, regurgitation, and chronic cough were no longer reported in the asymptomatic patients at all. Flexible endoscopic treatment of ZD with the sb knife and overtube is effective, safe, and has lasting effects with a relatively low recurrence rate.

  20. Usefulness of underwater endoscopic submucosal dissection in saline solution with a monopolar knife for colorectal tumors (with videos).

    PubMed

    Nagata, Mitsuru

    2018-05-01

    Generally, colorectal endoscopic submucosal dissection (ESD) is performed with a monopolar knife with CO 2 supply from an endoscope. There are few case reports about underwater ESD (UESD) in saline solution with a bipolar knife. The usefulness and safety of UESD in saline solution with a monopolar knife are unclear. The present study aimed to investigate the usefulness and safety of UESD in saline solution with a monopolar knife for colorectal tumors. This retrospective, observational study on UESD for colorectal tumors included 26 colorectal tumors from 24 patients treated with UESD at our department between October 2015 and February 2017. The characteristics of patients, factors associated with ESD difficulty, treatment results, and variations in blood test data before and after UESD were analyzed. En bloc resection was successful in all lesions without any serious adverse events. The median major diameter of the resected specimens was 30 mm (interquartile range [IQR], 28-35) and of the tumor 22.5 mm (IQR, 17.8-25.3). The median procedure time was 60 minutes (IQR, 45-111) and median speed of dissection 10.4 mm 2 /min (IQR, 6.4-12.2). No cases of perforation occurred. Post-ESD bleeding occurred in only 1 case, and endoscopic hemostasis was achieved. There was no case of electrolyte imbalance requiring treatment after UESD. UESD in saline solution with a monopolar knife for colorectal tumors is useful and safe. UESD has potential advantages that should be further assessed. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  1. Surgical technique for en bloc transurethral resection of bladder tumour with a Hybrid Knife(®).

    PubMed

    Islas-García, J J O; Campos-Salcedo, J G; López-Benjume, B I; Torres-Gómez, J J; Aguilar-Colmenero, J; Martínez-Alonso, I A; Gil-Villa, S A

    2016-05-01

    Bladder cancer is the second most common malignancy of the urinary tract and the 9th worldwide. Latin American has an incidence of 5.6 per 100,000 inhabitants per year. Seventy-five percent of newly diagnosed cases are nonmuscle invasive bladder cancer, and 25% of cases present as muscle invasive. The mainstay of treatment for nonmuscle invasive bladder cancer is loop transurethral resection. In 2013, the group led by Dr Mundhenk of the University Hospital of Tübingen, Germany, was the first to describe the Hybrid Knife(®) equipment for performing en bloc bladder tumour resection, with favourable functional and oncological results. To describe the surgical technique of en bloc bladder tumour resection with a Hybrid Knife(®) as an alternative treatment for nonmuscle invasive bladder tumours. A male patient was diagnosed by urotomography and urethrocystoscopy with a bladder tumour measuring 2×1cm on the floor. En bloc transurethral resection of the bladder tumour was performed with a Hybrid Knife(®). Surgery was performed for 35min, with 70 watts for cutting and 50 watts for coagulation, resecting and evacuating en bloc the bladder tumour, which macroscopically included the muscle layer of the bladder. There were no complications. The technique of en bloc bladder tumour resection with Hybrid Knife(®) is an effective alternative to bipolar loop transurethral resection. Resection with a Hybrid Knife(®) is a procedure with little bleeding and good surgical vision and minimises the risk of bladder perforation and tumour implants. The procedure facilitates determining the positivity of the neoplastic process, vascular infiltration and bladder muscle invasion in the histopathology study. Copyright © 2015 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Peroral Endoscopic Myotomy in Children: First Experience With a New Triangular Knife.

    PubMed

    Nabi, Zaheer; Ramchandani, Mohan; Chavan, Radhika; Tandan, Manu; Kalapala, Rakesh; Darisetty, Santosh; Reddy, Duvuur Nageshwar

    2018-01-01

    Peroral endoscopic myotomy (POEM) is a novel treatment modality for achalasia cardia. The procedure is technically challenging and time consuming. Recently, a new triangle tip knife (TTJ) has been introduced, which is equipped with water jet facility. In the present study, we analyzed the feasibility, safety, and efficacy of POEM in children with new triangle tip knife. We retrospectively evaluated the data of children (18 years or younger) who underwent POEM using TTJ knife at our institution. All POEM procedures were performed under general anesthesia in an endoscopy suite. Technical feasibility, safety, efficacy, and procedure duration were assessed. Ten children (4 boys, 6 girls) with mean age of 14.2 ± 2.74 (9-18) years, underwent POEM with TTJ knife. The subtypes of achalasia cardia were type I (4), type II (5), and type III (1). Two children had prior treatment with pneumatic balloon dilatation. POEM was performed via anterior route in majority of children (70%). Mean operating time was 47.6 ± 19.74 (30-98) minutes with no significant difference between anterior and posterior approaches to POEM (48.57 ± 24.01 vs 45.3 ± 3.51; P < 0.05). Four gas-related adverse events were encountered including capnoperitoneum and retroperitoneal carbon dioxide in 2 children each. Clinical success was noticed in 9 children with significant reduction in Eckardt score at 1 month after POEM (6.7 ± 1.49 vs 0.3 ± 0.48; P = 0.0001). POEM can be efficiently performed with new triangle knife equipped with water jet technique. Integration of water jet reduces procedure duration and technical difficulty with POEM.

  3. Leksell Gamma Knife radiosurgery of the jugulotympanic glomus tumor: long-term results.

    PubMed

    Liscak, Roman; Urgosik, Dusan; Chytka, Tomas; Simonova, Gabriela; Novotny, Josef; Vymazal, Josef; Guseynova, Khumar; Vladyka, Vilibald

    2014-12-01

    Glomus tumors usually display indolent behavior, and the effectiveness of radiation in stopping their growth can be assessed after long-term follow-up. Currently only midterm results of radiosurgery are available, so the authors included patients treated by Gamma Knife at least 10 years ago in this study to obtain a perspective of long-term results. During the period from 1992 to 2003, the Gamma Knife was used to treat 46 patients with glomus tumors. The age of the patients ranged from 21 to 79 years (median 56 years). Gamma Knife radiosurgery was the primary treatment in 17 patients (37%). Open surgery preceded radiosurgery in 46% of cases, embolization in 17%, and fractionated radiotherapy in 4%. The volume of the tumor ranged from 0.2 to 24.3 cm(3) (median 3.6 cm(3)). The minimal dose to the tumor margin ranged between 10 and 30 Gy (median 20 Gy). One patient was lost for follow-up after radiosurgery. Clinical follow-up was available in 45 patients and 44 patients were followed with MRI in a follow-up period that ranged from 12 to 217 months (median 118 months). Neurological deficits improved in 19 (42%) of 45 patients and deteriorated in 2 patients (4%). Tumor size decreased in 34 (77%) of 44 patients with imaging follow-up, while an increase in volume was observed in 1 patient (2%) 182 months after radiosurgery and Gamma Knife treatment was repeated. One patient underwent another Gamma Knife treatment for secondary induced meningioma close to the glomus tumor 98 months after initial radiosurgical treatment. Seven patients died 22-96 months after radiosurgery (median 48 months), all for unrelated reasons. Radiosurgery has proved to be a safe treatment with a low morbidity rate and a reliable long-term antiproliferative effect.

  4. A continuous arc delivery optimization algorithm for CyberKnife m6.

    PubMed

    Kearney, Vasant; Descovich, Martina; Sudhyadhom, Atchar; Cheung, Joey P; McGuinness, Christopher; Solberg, Timothy D

    2018-06-01

    This study aims to reduce the delivery time of CyberKnife m6 treatments by allowing for noncoplanar continuous arc delivery. To achieve this, a novel noncoplanar continuous arc delivery optimization algorithm was developed for the CyberKnife m6 treatment system (CyberArc-m6). CyberArc-m6 uses a five-step overarching strategy, in which an initial set of beam geometries is determined, the robotic delivery path is calculated, direct aperture optimization is conducted, intermediate MLC configurations are extracted, and the final beam weights are computed for the continuous arc radiation source model. This algorithm was implemented on five prostate and three brain patients, previously planned using a conventional step-and-shoot CyberKnife m6 delivery technique. The dosimetric quality of the CyberArc-m6 plans was assessed using locally confined mutual information (LCMI), conformity index (CI), heterogeneity index (HI), and a variety of common clinical dosimetric objectives. Using conservative optimization tuning parameters, CyberArc-m6 plans were able to achieve an average CI difference of 0.036 ± 0.025, an average HI difference of 0.046 ± 0.038, and an average LCMI of 0.920 ± 0.030 compared with the original CyberKnife m6 plans. Including a 5 s per minute image alignment time and a 5-min setup time, conservative CyberArc-m6 plans achieved an average treatment delivery speed up of 1.545x ± 0.305x compared with step-and-shoot plans. The CyberArc-m6 algorithm was able to achieve dosimetrically similar plans compared to their step-and-shoot CyberKnife m6 counterparts, while simultaneously reducing treatment delivery times. © 2018 American Association of Physicists in Medicine.

  5. Application of Electrocautery Needle Knife Combined with Balloon Dilatation versus Balloon Dilatation in the Treatment of Tracheal Fibrotic Scar Stenosis.

    PubMed

    Bo, Liyan; Li, Congcong; Chen, Min; Mu, Deguang; Jin, Faguang

    Electrocautery needle knives can largely reduce scar and granulation tissue hyperplasia and play an important role in treating patients with benign stricture. The aim of this retrospective study was to evaluate the efficacy and safety of electrocautery needle knife combined with balloon dilatation versus balloon dilatation alone in the treatment of tracheal stenosis caused by tracheal intubation or tracheotomy. We retrospectively analysed the clinical data of 43 patients with tracheal stenosis caused by tracheotomy or tracheal intubation in our department from January 2013 to January 2016. Among these 43 patients, 23 had simple web-like stenosis and 20 had complex steno sis. All patients were treated under general anaesthesia, and the treatment methods were (1) balloon dilatation alone, (2) needle knife excision of fibrotic tissue combined with balloon dilatation, and (3) needle knife radial incision of fibrotic tissue combined with balloon dilatation. After treatment the symptoms, such as shortness of breath, were markedly improved immediately in all cases. The stenosis degree of patients who were treated with the elec-trocautery needle knife combined with balloon dilatation had better improvement compared with that of those treated with balloon dilatation treatment alone after 3 months (0.45 ± 0.04 vs. 0.67 ± 0.05, p < 0.01), and the proportion of restenosis occurrence that required further treatment was decreased at 6 months (46.9 vs. 81.8%), especially for the web-like stenosis patients, as most of their stenoses dilated with no obvious restenosis and achieved clinical cure. Electrocautery needle knife combined with balloon dilatation is an effective and safe treatment for tracheal fibrotic stenosis compared with balloon dilatation alone. © 2017 S. Karger AG, Basel.

  6. Brain metastases in women with epithelial ovarian cancer: multimodal treatment including surgery or gamma-knife radiation is associated with prolonged survival.

    PubMed

    Niu, Xiaoyu; Rajanbabu, Anupama; Delisle, Megan; Peng, Feng; Vijaykumar, Dehannathuparambil K; Pavithran, Keechilattu; Feng, Yukuan; Lau, Susie; Gotlieb, Walter H; Press, Joshua Z

    2013-09-01

    To explore the impact of treatment modality on survival in patients with brain metastases from epithelial ovarian cancer. We conducted a retrospective review of cases of ovarian cancer with brain metastases treated at institutions in three countries (Canada, China, and India) and conducted a search for studies regarding brain metastases in ovarian cancer reporting survival related to treatment modality. Survival was analyzed according to treatment regimens involving (1) some form of surgical excision or gamma-knife radiation with or without other modalities, (2) other modalities without surgery or gamma-knife radiation, or (3) palliation only. Twelve patients (mean age 56 years) with detailed treatment/outcome data were included; five were from China, four from Canada, and three from India. Median time from diagnosis of ovarian cancer to brain metastasis was 19 months (range 10 to 37 months), and overall median survival time from diagnosis of ovarian cancer was 38 months (13 to 82 months). Median survival time from diagnosis of brain metastasis was 17 months (1 to 45 months). Among patients who had multimodal treatment including gamma-knife radiotherapy or surgical excision, the median survival time after the identification of brain metastasis was 25.6 months, compared with 6.0 months in patients whose treatment did not include this type of focused localized modality (P = 0.006). Analysis of 20 studies also indicated that use of gamma-knife radiotherapy and excisional surgery in multi-modal treatment resulted in improved median survival interval (25 months vs. 6.0 months, P < 0.001). In the subset of patients with brain metastases from ovarian cancer, prolonged survival may result from use of multidisciplinary therapy, particularly if metastases are amenable to localized treatments such as gamma-knife radiotherapy and surgical excision.

  7. Adjustable knife cuts honeycomb material to specified depth

    NASA Technical Reports Server (NTRS)

    Rauschl, J. A.

    1966-01-01

    Calibrated, adjustable knife cuts aluminum honeycomb or other soft materials to a desired depth. The frame of the device accommodates standard commercial blades. Since the blade is always visible to the operator, the device can be used on any straight or irregular layout line.

  8. Striated abrasions from a knife with non-serrated blade--identification of the instrument of crime on the basis of an experiment with material evidence.

    PubMed

    Kaliszan, Michał; Karnecki, Karol; Akçan, Ramazan; Jankowski, Zbigniew

    2011-09-01

    This paper presents an experiment with a knife seized as material evidence in a homicide case. The reason for the experiment was the necessity to determine whether the injuries of the deceased could have been inflicted with this instrument since in the course of the investigation doubt arose as to the origin of linear, parallel scratches around one of the wounds and on the abdominal integuments suggesting a serrated blade. The knife found near the crime scene had a smooth blade and small serrations only on the borderline between its blade and hilt. However, the performed experiment showed that if the knife is directed towards the integuments of the body in a special way, its serrations, even though not located on the blade itself, may leave such striated marks on the body, as those found during the autopsy, suggesting their origin from a serrated blade.

  9. Intricacies of Using Kevlar and Thermal Knives in a Deployable Release System: Issues and Solutions

    NASA Technical Reports Server (NTRS)

    Stewart, Alphonso C.; Hair, Jason H.; Broduer, Steve (Technical Monitor)

    2002-01-01

    The utilization of Kevlar cord and thermal knives in a deployable release system produces a number of issues that must be addressed in the design of the system. This paper proposes design considerations that minimize the major issues, thermal knife failure, Kevlar cord relaxation, and the measurement of the cord tension. Design practices can minimize the potential for thermal knife laminate and element damage that result in failure of the knife. A process for in-situ inspection of the knife with resistance, rather than continuity, checks and 10x zoom optical imaging can detect damaged knives. Tests allow the characterization of the behavior of the particular Kevlar cord in use and the development of specific pre-stretching techniques and initial tension values needed to meet requirements. A new method can accurately measure the tension of the Kevlar cord using a guitar tuner, because more conventional methods do not apply to arimid cords such as Kevlar.

  10. Intricacies of Using Kevlar Cord and Thermal Knives in a Deployable Release System: Issues and Solutions

    NASA Technical Reports Server (NTRS)

    Stewart, Alphonso; Hair, Jason H.

    2002-01-01

    The utilization of Kevlar cord and thermal knives in a deployable release system produces a number of issues that must be addressed in the design of the system. This paper proposes design considerations that minimize the major issues, thermal knife failure, Kevlar cord relaxation, and the measurement of the cord tension. Design practices can minimize the potential for thermal knife laminate and element damage that result in failure of the knife. A process for in-situ inspection of the knife with resistance, rather than continuity, checks and 10x zoom optical imaging can detect damaged knives. Tests allow the characterization of the behavior of the particular Kevlar cord in use and the development of specific prestretching techniques and initial tension values needed to meet requirements. A new method can accurately measure the tension of the Kevlar cord using a guitar tuner, because more conventional methods do not apply to arimid cords such as Kevlar.

  11. Development of a lemon cutting machine.

    PubMed

    Hrishikesh Tavanandi, A; Deepak, S; Venkateshmurthy, K; Raghavarao, K S M S

    2014-12-01

    Cutting of lemon and other similar fruits is conventionally done manually by sharp knife, which is labor intensive and often un-hygienic. In the present work, a device has been designed and developed for cutting of lemon hygienically into four pieces of similar shape based on stationery cutters and rotating centralizing/locating slit plate concept. Machine has a unique knife assembly consisting of two bird wing shaped knives, joined by welding perpendicularly to a vertical knife, so that the lemon can be cut into four pieces in a single sweep. Six numbers of rotating centralizing/locating slit plates are welded on to the side plates and the plates carry a groove on its inner face, to enable the wing shaped knife to complete the horizontal cut. The rotating slit plates, having centralizing angle of 90°, are rotated by an electric geared motor. The prototype machine has capacity of over 5,000 lemons/h with a power consumption of 0.11 kW.

  12. Gamma Knife radiosurgery in pituitary adenomas: Why, who, and how to treat?

    PubMed

    Castinetti, Frederic; Brue, Thierry

    2010-08-01

    Pituitary adenomas are benign tumors that can be either secreting (acromegaly, Cushing's disease, prolactinomas) or non-secreting. Transsphenoidal neurosurgery is the gold standard treatment; however, it is not always effective. Gamma Knife radiosurgery is a specific modality of stereotactic radiosurgery, a precise radiation technique. Several studies reported the efficacy and low risk of adverse effects induced by this technique: in secreting pituitary adenomas, hypersecretion is controlled in about 50% of cases and tumor volume is stabilized or decreased in 80-90% of cases, making Gamma Knife a valuable adjunctive or first-line treatment. As hormone levels decrease progressively, the main drawback is the longer time to remission (12-60 months), requiring an additional treatment during this period. Hypopituitarism is the main side effect, observed in 20-40% cases. Gamma Knife is thus useful in the therapeutic algorithms of pituitary adenomas in well-defined indications, mainly low secreting small lesions well identified on magnetic resonance imaging (MRI).

  13. Oscillatory shear rheology measurements and Newtonian modeling of insoluble monolayers

    NASA Astrophysics Data System (ADS)

    Rasheed, Fayaz; Raghunandan, Aditya; Hirsa, Amir H.; Lopez, Juan M.

    2017-04-01

    Circular systems are advantageous for interfacial studies since they do not suffer from end effects, but their hydrodynamics is more complicated because their flows are not unidirectional. Here, we analyze the shear rheology of a harmonically driven knife-edge viscometer through experiments and computations based on the Navier-Stokes equations with a Newtonian interface. The measured distribution of phase lag in the surface velocity relative to the knife-edge speed is found to have a good signal-to-noise ratio and provides robust comparisons to the computations. For monomolecular films of stearic acid, the surface shear viscosity deduced from the model was found to be the same whether the film is driven steady or oscillatory, for an order of magnitude range in driving frequencies and amplitudes. Results show that increasing either the amplitude or forcing frequency steepens the phase lag next to the knife edge. In all cases, the phase lag is linearly proportional to the radial distance from the knife edge and scales with surface shear viscosity to the power -1 /2 .

  14. Technical note: A 3D-printed phantom for routine accuracy check of Gamma Knife Icon HDMM system.

    PubMed

    Wu, Chuan; Radevic, Marlyn B; Glass, Jennifer S; Skubic, Stan E

    2018-05-23

    To report a novel 3D-printed device ("SH phantom") that is designed for routine accuracy check of the Gamma Knife Icon High Definition Motion Management (HDMM) system. SH phantom was designed using tinkerCAD software and printed on a commercial 3D printer. We evaluated the SH phantom on our Gamma Knife Icon unit regarding its usability and accuracy for routine HDMM QA. Single-axis and multiple-axis measurements validated the SH phantom design and implementation. An HDMM QA accuracy of 0.22 mm or better along single axis was found using SH phantom. The SH phantom proved to be a quick and simple tool to use to perform the HDMM system QA. The SH phantom was tested successfully and adopted by us as part of monthly QA for the Gamma Knife Icon. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  15. Completion of Gamma Knife radiosurgery for AVM treatment after unplanned interruption-technical note.

    PubMed

    Raman, Hari S; Santanam, Lakshmi; Vellimana, Ananth K; Drzymala, Robert E; Tsien, Christina I; Zipfel, Gregory J

    2018-02-17

    Gamma Knife radiosurgery is an established technique for non-urgent treatment of various intracranial pathologies. Intra-procedural dislodgement of the stereotactic frame is an uncommon occurrence that could lead to abortion of ongoing treatment and necessitate more invasive treatment strategies. In this case report, we describe a novel method for resumption of Gamma Knife treatment after an unplanned intra-procedural interruption. The case example involves a radiosurgical treatment of a Spetzler-Martin grade I arteriovenous malformation. Our technique involves integration of scans and coordinate systems from two imaging sessions using the composite isodose line to resolve translational differences, thereby limiting delivery of remaining shots to the untreated region of the lesion. MRI follow-up at 13 months showed a reduction in the nidus size with no evidence of any radiation injury to the surrounding brain parenchyma. We believe this technique will allow care teams to effectively salvage interrupted Gamma Knife procedures and reduce progression to more invasive treatment options.

  16. Characteristics of Bone Injuries Resulting from Knife Wounds Incised with Different Forces.

    PubMed

    Humphrey, Caitlin; Kumaratilake, Jaliya; Henneberg, Maciej

    2017-11-01

    The aim of this research was to experimentally determine the characteristics of incised bone wounds, which are commonly found in defense injuries. A specially constructed pivoting arm device was used to inflict wounds with controlled forces and direction. Five knives were selected to inflict the wounds on porcine forelimbs. Eight incised wounds were made per knife per force. A larger knife and a greater force caused longer and wider bone wounds. Comparisons of individual knives at the two forces produced varying results in the bone wounds. A correlation was seen between the force and the length (r = 0.69), width (r = 0.63), and depth (r = 0.57) of bone wounds. Serrated-edge and nonserrated knives can be distinguished from the appearance of the wound. The outcomes may be applicable in forensic investigations to ascertain the forces associated with incised wounds and identify the specific knife used. © 2017 American Academy of Forensic Sciences.

  17. Intricacies of Using Kevlar Cord and Thermal Knives in a Deployable Release System: Issues and Solutions

    NASA Astrophysics Data System (ADS)

    Stewart, Alphonso; Hair, Jason H.

    2002-04-01

    The utilization of Kevlar cord and thermal knives in a deployable release system produces a number of issues that must be addressed in the design of the system. This paper proposes design considerations that minimize the major issues, thermal knife failure, Kevlar cord relaxation, and the measurement of the cord tension. Design practices can minimize the potential for thermal knife laminate and element damage that result in failure of the knife. A process for in-situ inspection of the knife with resistance, rather than continuity, checks and 10x zoom optical imaging can detect damaged knives. Tests allow the characterization of the behavior of the particular Kevlar cord in use and the development of specific prestretching techniques and initial tension values needed to meet requirements. A new method can accurately measure the tension of the Kevlar cord using a guitar tuner, because more conventional methods do not apply to arimid cords such as Kevlar.

  18. Theory of High Frequency Rectification by Silicon Crystals

    DOE R&D Accomplishments Database

    Bethe, H. A.

    1942-10-29

    The excellent performance of British "red dot" crystals is explained as due to the knife edge contact against a polished surface. High frequency rectification depends critically on the capacity of the rectifying boundary layer of the crystal, C. For high conversion efficiency, the product of this capacity and of the "forward" (bulk) resistance R {sub b} of the crystal must be small. For a knife edge, this product depends primarily on the breadth of the knife edge and very little upon its length. The contact can therefore have a rather large area which prevents burn-out. For a wavelength of 10 cm. the computations show that the breadth of the knife edge should be less than about 10 {sup -3} cm. For a point contact the radius must be less than 1.5 x 10 {sup -3} cm. and the resulting small area is conducive to burn-out. The effect of "tapping" is probably to reduce the area of contact. (auth)

  19. A new strategy of CyberKnife treatment system based radiosurgery followed by early use of adjuvant bevacizumab treatment for brain metastasis with extensive cerebral edema.

    PubMed

    Wang, Yang; Wang, Enmin; Pan, Li; Dai, Jiazhong; Zhang, Nan; Wang, Xin; Liu, Xiaoxia; Mei, Guanghai; Sheng, Xiaofang

    2014-09-01

    Bevacizumab blocks the effects of vascular endothelial growth factor in leakage-prone capillaries and has been suggested as a new treatment for cerebral radiation edema and necrosis. CyberKnife is a new, frameless stereotactic radiosurgery system. This work investigated the safety and efficacy of CyberKnife followed by early bevacizumab treatment for brain metastasis with extensive cerebral edema. The eligibility criteria of the patients selected for radiosurgery followed by early use of adjuvant bevacizumab treatment were: (1) brain tumors from metastasis with one solitary brain lesion and symptomatic extensive cerebral edema; (2) >18 years of age; (3) the patient refused surgery due to the physical conditions and the risk of surgery; (4) no contraindications for bevacizumab. (5) bevacizumab was applied for a minimum of 2 injections and a maximum of 6 injections with a 2-week interval between treatments, beginning within 2 weeks of the CyberKnife therapy; (6) Karnofsky performance status (KPS) ≥30. Tumor size and edema were monitored by magnetic resonance imaging (MRI). Dexamethasone dosage, KPS, adverse event occurrence and associated clinical outcomes were also recorded. Eight patients were accrued for this new treatment. Radiation dose ranged from 20 to 33 Gy in one to five sessions, prescribed to the 61-71 % isodose line. Bevacizumab therapy was administered 3-10 days after completion of CyberKnife treatment for a minimum of two cycles (5 mg/kg, at 2-week intervals). MRI revealed average reductions of 55.8 % (post-gadolinium) and 63.4 % (T2/FLAIR). Seven patients showed significant clinical neurological improvements. Dexamethasone was reduced in all patients, with five successfully discontinuing dexamethasone treatment 4 weeks after bevacizumab initiation. Hypertension, a bevacizumab-related adverse event, occurred in one patient. After 3-8 months, all patients studied were alive and primary brain metastases were under control, 2 developed new brain metastases and underwent salvage CyberKnife treatment. Recurrent edema and emerging radiation necrosis were not observed. CyberKnife radiosurgery followed by early use of bevacizumab is promising and appears safe for treatment of brain metastases with extensive cerebral edema.

  20. Daniel K. Inouye Solar Telescope: computational fluid dynamic analyses and evaluation of the air knife model

    NASA Astrophysics Data System (ADS)

    McQuillen, Isaac; Phelps, LeEllen; Warner, Mark; Hubbard, Robert

    2016-08-01

    Implementation of an air curtain at the thermal boundary between conditioned and ambient spaces allows for observation over wavelength ranges not practical when using optical glass as a window. The air knife model of the Daniel K. Inouye Solar Telescope (DKIST) project, a 4-meter solar observatory that will be built on Haleakalā, Hawai'i, deploys such an air curtain while also supplying ventilation through the ceiling of the coudé laboratory. The findings of computational fluid dynamics (CFD) analysis and subsequent changes to the air knife model are presented. Major design constraints include adherence to the Interface Control Document (ICD), separation of ambient and conditioned air, unidirectional outflow into the coudé laboratory, integration of a deployable glass window, and maintenance and accessibility requirements. Optimized design of the air knife successfully holds full 12 Pa backpressure under temperature gradients of up to 20°C while maintaining unidirectional outflow. This is a significant improvement upon the .25 Pa pressure differential that the initial configuration, tested by Linden and Phelps, indicated the curtain could hold. CFD post- processing, developed by Vogiatzis, is validated against interferometry results of initial air knife seeing evaluation, performed by Hubbard and Schoening. This is done by developing a CFD simulation of the initial experiment and using Vogiatzis' method to calculate error introduced along the optical path. Seeing error, for both temperature differentials tested in the initial experiment, match well with seeing results obtained from the CFD analysis and thus validate the post-processing model. Application of this model to the realizable air knife assembly yields seeing errors that are well within the error budget under which the air knife interface falls, even with a temperature differential of 20°C between laboratory and ambient spaces. With ambient temperature set to 0°C and conditioned temperature set to 20°C, representing the worst-case temperature gradient, the spatial rms wavefront error in units of wavelength is 0.178 (88.69 nm at λ = 500 nm).

  1. SU-F-T-485: Independent Remote Audits for TG51 NonCompliant Photon Beams Performed by the IROC Houston QA Center

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alvarez, P; Molineu, A; Lowenstein, J

    Purpose: IROC-H conducts external audits for output check verification of photon and electron beams. Many of these beams can meet the geometric requirements of the TG 51 calibration protocol. For those photon beams that are non TG 51 compliant like Elekta GammaKnife, Accuray CyberKnife and TomoTherapy, IROC-H has specific audit tools to monitor the reference calibration. Methods: IROC-H used its TLD and OSLD remote monitoring systems to verify the output of machines with TG 51 non compliant beams. Acrylic OSLD miniphantoms are used for the CyberKnife. Special TLD phantoms are used for TomoTherapy and GammaKnife machines to accommodate the specificmore » geometry of each machine. These remote audit tools are sent to institutions to be irradiated and returned to IROC-H for analysis. Results: The average IROC-H/institution ratios for 480 GammaKnife, 660 CyberKnife and 907 rotational TomoTherapy beams are 1.000±0.021, 1.008±0.019, 0.974±0.023, respectively. In the particular case of TomoTherapy, the overall ratio is 0.977±0.022 for HD units. The standard deviations of all results are consistent with values determined for TG 51 compliant photon beams. These ratios have shown some changes compared to values presented in 2008. The GammaKnife results were corrected by an experimentally determined scatter factor of 1.025 in 2013. The TomoTherapy helical beam results are now from a rotational beam whereas in 2008 the results were from a static beam. The decision to change modality was based on recommendations from the users. Conclusion: External audits of beam outputs is a valuable tool to confirm the calibrations of photon beams regardless of whether the machine is TG 51 or TG 51 non compliant. The difference found for TomoTherapy units is under investigation. This investigation was supported by IROC grant CA180803 awarded by the NCI.« less

  2. From decay to complete breaking: pulling the strings in SU(2) Yang-Mills theory.

    PubMed

    Pepe, M; Wiese, U-J

    2009-05-15

    We study {2Q+1} strings connecting two static charges Q in (2+1)D SU(2) Yang-Mills theory. While the fundamental {2} string between two charges Q=1/2 is unbreakable, the adjoint {3} string connecting two charges Q=1 can break. When a {4} string is stretched beyond a critical length, it decays into a {2} string by gluon pair creation. When a {5} string is stretched, it first decays into a {3} string, which eventually breaks completely. The energy of the screened charges at the ends of a string is well described by a phenomenological constituent gluon model.

  3. Two cases of electrocautery incision therapy using an insulated-tip knife for treatment of symptomatic benign short-segment colonic stenosis following colonic resection.

    PubMed

    Kwon, Jang Hoon; Han, Koon Hee; Kim, Moon Ho; Jang, Woo Sung; Yun, Jung Ho; Song, Yun A; Park, Jong Kyu; Cheon, Gab Jin

    2014-09-25

    Anastomotic stenosis of the colon is not an uncommon finding; however, its frequency varies from one study to another. Traditionally, postoperative colonic stenosis is managed surgically. However, endoscopic therapy has recently become the preferred treatment modality over traditional surgery. Good short-term success has been achieved with use of endoscopic balloon dilation; however, restenosis may occur over time in 14% to 25% of patients. The current report showed the effectiveness and usefulness of an insulated-tip knife (IT-knife) for electrocautery therapy of a patient with symptomatic anastomotic colonic stenosis.

  4. Reproduction, longevity and survival of the cactus moth, Cactoblastis cactorum (Lepidoptera: Pyralidae).

    USDA-ARS?s Scientific Manuscript database

    Screened potted cactus plants (Opuntia ficus-indica (L.) Mill.) containing pairs of adult male and female cactus moths, Cactoblastis cactorum (Berg) (Lepidoptera: Pyralidae), were placed in a cactus field in St. Marks, Florida to measure oviposition patterns under field-realistic conditions. Results...

  5. Estimation of the costs of cervical cancer screening, diagnosis and treatment in rural Shanxi Province, China: a micro-costing study

    PubMed Central

    2012-01-01

    Background Cost estimation is a central feature of health economic analyses. The aim of this study was to use a micro-costing approach and a societal perspective to estimate aggregated costs associated with cervical cancer screening, diagnosis and treatment in rural China. Methods We assumed that future screening programs will be organized at a county level (population ~250,000), and related treatments will be performed at county or prefecture hospitals; therefore, this study was conducted in a county and a prefecture hospital in Shanxi during 2008–9. Direct medical costs were estimated by gathering information on quantities and prices of drugs, supplies, equipment and labour. Direct non-medical costs were estimated via structured patient interviews and expert opinion. Results Under the base case assumption of a high-volume screening initiative (11,475 women screened annually per county), the aggregated direct medical costs of visual inspection, self-sampled careHPV (Qiagen USA) screening, clinician-sampled careHPV, colposcopy and biopsy were estimated as US$2.64,$7.49,$7.95,$3.90 and $5.76, respectively. Screening costs were robust to screening volume (<5% variation if 2,000 women screened annually), but costs of colposcopy/biopsy tripled at the lower volume. Direct medical costs of Loop Excision, Cold-Knife Conization and Simple and Radical Hysterectomy varied from $61–544, depending on the procedure and whether conducted at county or prefecture level. Direct non-medical expenditure varied from $0.68–$3.09 for screening/diagnosis and $83–$494 for pre-cancer/cancer treatment. Conclusions Diagnostic costs were comparable to screening costs for high-volume screening but were greatly increased in lower-volume situations, which is a key consideration for the scale-up phase of new programs. The study’s findings will facilitate cost-effectiveness evaluation and budget planning for cervical cancer prevention initiatives in China. PMID:22624619

  6. Endoscopic Submucosal Dissection Using a Novel Versatile Knife: An Animal Feasibility Study (with Video)

    PubMed Central

    Kwon, Chang-Il; Kim, Gwangil; Kim, Won Hee; Ko, Kwang Hyun; Hong, Sung Pyo; Jeong, Seok; Lee, Don Haeng

    2014-01-01

    Background/Aims In order to reduce the procedure time and the number of accessory changes during endoscopic submucosal dissection (ESD), we developed a novel versatile knife, which has the combined advantages of several conventional knives. The aim of this study was to compare the efficacy, safety, and histological quality of ESD performed using this novel versatile knife and a combination of several conventional knives. Methods This was an in vivo animal study comparing two different modalities of ESD in mini-pigs. Completion time of each resection was documented, and the resected specimens were retrieved and evaluated for completeness. To assess the quality control of the procedures and adverse events, detailed histopathological examinations were performed. Results A total of 18 specimens were dissected by ESD safely and easily (nine specimens using the new versatile knife; nine specimens by mixing conventional knives). All resections were completed as en bloc resections. There was no significant difference in procedure time between the 2 modalities (456 seconds vs. 355 seconds, p=0.258) and cutting speed (1.983 mm2/sec vs. 1.57 mm2/sec, p=1.000). The rate of adverse events and histological quality did not statistically differ between the modalities. Conclusions ESD with a versatile knife appeared to be an easy, safe, and technically efficient method. PMID:25505721

  7. Repeat Gamma-Knife Radiosurgery for Refractory or Recurrent Trigeminal Neuralgia with Consideration About the Optimal Second Dose.

    PubMed

    Park, Seong-Cheol; Kwon, Do Hoon; Lee, Do Hee; Lee, Jung Kyo

    2016-02-01

    To investigate adequate radiation doses for repeat Gamma Knife radiosurgery (GKS) for trigeminal neuralgia in our series and meta-analysis. Fourteen patients treated by ipsilateral repeat GKS for trigeminal neuralgia were included. Median age of patients was 65 years (range, 28-78), the median target dose, 140-180). Patients were followed a median of 10.8 months (range, 1-151) after the second gamma-knife surgery. Brainstem dose analysis and vote-counting meta-analysis of 19 studies were performed. After the second gamma-knife radiosurgeries, pain was relieved effectively in 12 patients (86%; Barrow Neurological Institute Pain Intensity Score I-III). Post-gamma-knife radiosurgery trigeminal nerve deficits were mild in 5 patients. No serious anesthesia dolorosa was occurred. The second GKS radiation dose ≤ 60 Gy was significantly associated with worse pain control outcome (P = 0.018 in our series, permutation analysis of variance, and P = 0.009 in the meta-analysis, 2-tailed Fisher's exact test). Cumulative dose ≤ 140-150 Gy was significantly associated with poor pain control outcome (P = 0.033 in our series and P = 0.013 in the meta-analysis, 2-tailed Fisher's exact test). A cumulative brainstem edge dose >12 Gy tended to be associated with trigeminal nerve deficit (P = 0.077). Our study suggests that the second GKS dose is a potentially important factor. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. The Shoemaker's Knife--An Approach of the Polya Type.

    ERIC Educational Resources Information Center

    Libeskind, Shlomo; Lott, Johnny W.

    1984-01-01

    Archimedes' shoemaker's knife problem is interesting in its own right and also allows the demonstration of heuristic teaching ideas and a different method of doing a routine construction. The focus in the article is on the thought processes involved and questions asked when attempting proofs with the problem. (MNS)

  9. Fertilizer placement to maximize nitrogen use by fescue

    USDA-ARS?s Scientific Manuscript database

    The method of fertilizer nitrogen(N) application can affect N uptake in tall fescue and therefore its yield and quality. Subsurface-banding (knife) of fertilizer maximizes fescue N uptake in the poorly-drained clay–pan soils of southeastern Kansas. This study was conducted to determine if knifed N r...

  10. Effect of particle size on enzymatic hydrolysis of pretreated Miscanthus

    USDA-ARS?s Scientific Manuscript database

    Particle size reduction is a crucial factor in transportation logistics as well as cellulosic conversion. The effect of particle size on enzymatic hydrolysis of pretreated Miscanthus x giganteus was determined. Miscanthus was ground using a hammer mill equipped with screens having 0.08, 2.0 or 6.0...

  11. Reconnaissance soil geochemistry at the Riverton Uranium Mill Tailings Remedial Action Site, Fremont County, Wyoming

    USGS Publications Warehouse

    Smith, David B.; Sweat, Michael J.

    2012-01-01

    Soil samples were collected and chemically analyzed from the Riverton Uranium Mill Tailings Remedial Action Site, which lies within the Wind River Indian Reservation in Fremont County, Wyoming. Nineteen soil samples from a depth of 0 to 5 centimeters were collected in August 2011 from the site. The samples were sieved to less than 2 millimeters and analyzed for 44 major and trace elements following a near-total multi-acid extraction. Soil pH was also determined. The geochemical data were compared to a background dataset consisting of 160 soil samples previously collected from the same depth throughout the State of Wyoming as part of another ongoing study by the U.S. Geological Survey. Risk from potentially toxic elements in soil from the site to biologic receptors and humans was estimated by comparing the concentration of these elements with soil screening values established by the U.S. Environmental Protection Agency. All 19 samples exceeded the carcinogenic human health screening level for arsenic in residential soils of 0.39 milligrams per kilogram (mg/kg), which represents a one-in-one-million cancer risk (median arsenic concentration in the study area is 2.7 mg/kg). All 19 samples also exceeded the lead and vanadium screening levels for birds. Eighteen of the 19 samples exceeded the manganese screening level for plants, 13 of the 19 samples exceeded the antimony screening level for mammals, and 10 of 19 samples exceeded the zinc screening level for birds. However, these exceedances are also found in soils at most locations in the Wyoming Statewide soil database, and elevated concentrations alone are not necessarily cause for alarm. Uranium and thorium, two other elements of environmental concern, are elevated in soils at the site as compared to the Wyoming dataset, but no human or ecological soil screening levels have been established for these elements.

  12. 18. DETAIL OF COMBINATION HANDWASH SINK/KNIFE STERILIZER ON SPLITTERS' PLATFORM; ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. DETAIL OF COMBINATION HANDWASH SINK/KNIFE STERILIZER ON SPLITTERS' PLATFORM; KNIVES AND CLEAVERS WERE CLEANED FREQUENTLY BY DIPPING THEM INTO STEAM-HEATED WATER IN THE RECTANGULAR TANK; NOTE FOOT-OPERATED FAUCETS - Rath Packing Company, Beef Killing Building, Sycamore Street between Elm & Eighteenth Streets, Waterloo, Black Hawk County, IA

  13. 19 CFR 12.96 - Imports unrestricted under the Act.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... OF THE TREASURY SPECIAL CLASSES OF MERCHANDISE Switchblade Knives § 12.96 Imports unrestricted under the Act. (a) Common and special purpose knives. Imported knives with a blade style designed for a... in condition as entered the imported knife is not a switchblade knife as defined in § 12.95(a)(1...

  14. Submillisecond Optical Knife-Edge Testing

    NASA Technical Reports Server (NTRS)

    Thurlow, P.

    1983-01-01

    Fast computer-controlled sampling of optical knife-edge response (KER) signal increases accuracy of optical system aberration measurement. Submicrosecond-response detectors in optical focal plane convert optical signals to electrical signals converted to digital data, sampled and feed into computer for storage and subsequent analysis. Optical data are virtually free of effects of index-of-refraction gradients.

  15. Knife River: Early Village Life on the Plains. Teaching with Historic Places.

    ERIC Educational Resources Information Center

    Metcalf, Fay

    This document, from the lesson plan series, "Teaching with Historic Places," examines the Native Americans who lived on the plains along the Knife River in what is now North Dakota. Following an introductory section, the document sets out student objectives, teaching activities, readings, and illustrations. The teaching activity…

  16. 76 FR 44358 - Notice of Lodging Proposed Consent Decree

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-25

    ... DEPARTMENT OF JUSTICE Notice of Lodging Proposed Consent Decree In accordance with Departmental Policy, 28 CFR 50.7, notice is hereby given that a proposed Consent Decree in United States v. Northstar Materials, Inc. (d/b/a Knife River Materials) & Knife River Corporation, Civil No. 0:11-cv-01950-RHK-LIB...

  17. "Fist, Stick, Knife, Gun": Getting Real in Upward Bound.

    ERIC Educational Resources Information Center

    Pace, Barbara G.; Adkins, Theresa A.

    2002-01-01

    Describes how a teacher found literature for Upward Bound students. Presents Geoffrey Canada's "Fist, Stick, Knife, Gun: A Personal History of Violence in America" as a nonfiction work to provide clarity and connections that might not have been available in a fictional work, yet it had elements of literary fiction that made the text…

  18. One Hand, Two Objects: Emergence of Affordance in Contexts

    ERIC Educational Resources Information Center

    Borghi, Anna M.; Flumini, Andrea; Natraj, Nikhilesh; Wheaton, Lewis A.

    2012-01-01

    Studies on affordances typically focus on single objects. We investigated whether affordances are modulated by the context, defined by the relation between two objects and a hand. Participants were presented with pictures displaying two manipulable objects linked by a functional (knife-butter), a spatial (knife-coffee mug), or by no relation. They…

  19. Re-Inventing Counterinsurgency Doctrine: Why The United States Failed in Iraq and Afghanistan

    DTIC Science & Technology

    2016-02-16

    5 Dr Richard Stubbs, 113-118. 6 John A. Nagl, Learning to Eat Soup With a Knife: Counterinsurgency Lessons From Malaya and Vietnam...Modern War in Theory and Practice. New York: The Penguin Press, 2014. Nagl, John A. Learning to Eat Soup With a Knife: Counterinsurgency Lessons From

  20. Re-Inventing Counterinsurgency Doctrine: Why the United States Failed in Iraq and Afghanistan

    DTIC Science & Technology

    2016-01-08

    5 Dr Richard Stubbs, 113-118. 6 John A. Nagl, Learning to Eat Soup With a Knife: Counterinsurgency Lessons From Malaya and Vietnam...Modern War in Theory and Practice. New York: The Penguin Press, 2014. Nagl, John A. Learning to Eat Soup With a Knife: Counterinsurgency Lessons From

  1. Quantitative phase tomography by using x-ray microscope with Foucault knife-edge scanning filter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Watanabe, Norio; Tsuburaya, Yuji; Shimada, Akihiro

    2016-01-28

    Quantitative phase tomography was evaluated by using a differential phase microscope with a Foucault knife-edge scanning filter. A 3D x-ray phase image of polystyrene beads was obtained at 5.4 keV. The reconstructed refractive index was fairly good agreement with the Henke’s tabulated data.

  2. Technical feasibility of endoscopic submucosal dissection of gastrointestinal epithelial neoplasms with a splash-needle.

    PubMed

    Fujishiro, Mitsuhiro; Kodashima, Shinya; Goto, Osamu; Ono, Satoshi; Muraki, Yosuke; Kakushima, Naomi; Omata, Masao

    2008-12-01

    Endoscopic submucosal dissection (ESD) permits the resection of large gastrointestinal epithelial neoplasms and neoplasms with submucosal fibrosis in an en bloc manner. However, the high frequency of complications accompanying ESD and its complex processes suggests that the process requires improvement. A total of 22 consecutive patients with gastrointestinal epithelial neoplasms were enrolled during a 6-month period to evaluate a novel endosurgical knife for ESD. This novel knife is known as the "splash-needle," and it is thin, short needle with a water-irrigation function. The technical results revealed that the rates of bloc resection and en bloc resection with tumor-free lateral/basal margins (R0 resection) were 91% (20/22) and 82% (18/22), respectively. There was no significant bleeding or perforation during or after ESD. The median operation time was 60 minutes (range, 20 to 210). The splash-needle is a promising novel endosurgical knife that is useful for less complicated ESD. The accumulation of knowledge and cases verifying its usefulness is necessary, and a study comparing the knife with first-generation endosurgical knives is also warranted.

  3. Quality assurance for gamma knives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, E.D.; Banks, W.W.; Fischer, L.E.

    1995-09-01

    This report describes and summarizes the results of a quality assurance (QA) study of the Gamma Knife, a nuclear medical device used for the gamma irradiation of intracranial lesions. Focus was on the physical aspects of QA and did not address issues that are essentially medical, such as patient selection or prescription of dose. A risk-based QA assessment approach was used. Sample programs for quality control and assurance are included. The use of the Gamma Knife was found to conform to existing standards and guidelines concerning radiation safety and quality control of external beam therapies (shielding, safety reviews, radiation surveys,more » interlock systems, exposure monitoring, good medical physics practices, etc.) and to be compliant with NRC teletherapy regulations. There are, however, current practices for the Gamma Knife not covered by existing, formalized regulations, standards, or guidelines. These practices have been adopted by Gamma Knife users and continue to be developed with further experience. Some of these have appeared in publications or presentations and are slowly finding their way into recommendations of professional organizations.« less

  4. Two-dimensional straightness measurement based on optical knife-edge sensing

    NASA Astrophysics Data System (ADS)

    Wang, Chen; Zhong, Fenghe; Ellis, Jonathan D.

    2017-09-01

    Straightness error is a parasitic translation along a perpendicular direction to the primary displacement axis of a linear stage. The parasitic translations could be coupled into other primary displacement directions of a multi-axis platform. Hence, its measurement and compensation are critical in precision multi-axis metrology, calibration, and manufacturing. This paper presents a two-dimensional (2D) straightness measurement configuration based on 2D optical knife-edge sensing, which is simple, light-weight, compact, and easy to align. It applies a 2D optical knife-edge to manipulate the diffraction pattern sensed by a quadrant photodetector, whose output voltages could derive 2D straightness errors after a calibration process. This paper analyzes the physical model of the configuration and performs simulations and experiments to study the system sensitivity, measurement nonlinearity, and error sources. The results demonstrate that the proposed configuration has higher sensitivity and insensitive to beam's vibration, compared with the conventional configurations without using the knife-edge, and could achieve ±0.25 μ m within a ±40 μ m measurement range along a 40 mm primary axial motion.

  5. Optimization of processing parameters of UAV integral structural components based on yield response

    NASA Astrophysics Data System (ADS)

    Chen, Yunsheng

    2018-05-01

    In order to improve the overall strength of unmanned aerial vehicle (UAV), it is necessary to optimize the processing parameters of UAV structural components, which is affected by initial residual stress in the process of UAV structural components processing. Because machining errors are easy to occur, an optimization model for machining parameters of UAV integral structural components based on yield response is proposed. The finite element method is used to simulate the machining parameters of UAV integral structural components. The prediction model of workpiece surface machining error is established, and the influence of the path of walking knife on residual stress of UAV integral structure is studied, according to the stress of UAV integral component. The yield response of the time-varying stiffness is analyzed, and the yield response and the stress evolution mechanism of the UAV integral structure are analyzed. The simulation results show that this method is used to optimize the machining parameters of UAV integral structural components and improve the precision of UAV milling processing. The machining error is reduced, and the deformation prediction and error compensation of UAV integral structural parts are realized, thus improving the quality of machining.

  6. Effect of Acupotomy on FAK-PI3K Signaling Pathways in KOA Rabbit Articular Cartilages

    PubMed Central

    Xie, Zhan-guo; Guo, Yan; Yu, Jia-Ni; Lu, Juan; Zhang, Wei; Wang, Li-Juan; Xu, Jing; Zhao, Rui-Li; Zhou, Shuai

    2017-01-01

    Objective By observing the needle-knife of KOA rabbit morphology, knee joint cartilage p-FAK, p-PI3K, Aggrecan gene, and protein expression, to study the effect of needle-knife to promote cartilage cell synthesis metabolism mechanism. Method 49 male New Zealand rabbits, randomly divided into normal group (Z), model group (M), model-inhibitors (MP), needle-knife group (D), needle-knife inhibitors group (DP), electroacupuncture group (E), and electroacupuncture inhibitors (EP). RT-PCR and Western Blot were used to test each animal cartilage p-FAK, p-PI3K, and Aggrecan gene and protein expression level. Results Compared with N group, p-FAK and p-PI3K protein and mRNA expression of M group, D group, and E group increased (P < 0.05), while the protein and mRNA expression of Aggrecan reduced (P < 0.05). Compared with M group, p-FAK, p-PI3K, Aggrecan protein, and mRNA of E and D group increased (P < 0.05). Compared with E group, p-FAK, p-PI3K, Aggrecan protein, and mRNA expression of D group increased (P < 0.05); after adding inhibitors, p-FAK, p-PI3K, Aggrecan protein, and mRNA expression reduced (P < 0.05). Conclusion Needle-knife therapy can promote the repairment of cartilage cells by activating FAK-PI3K signaling pathways, promoting the synthesis of cartilage cell metabolism. PMID:29234400

  7. Measuring the resolution of uncompressed plastic sections cut using an oscillating knife ultramicrotome.

    PubMed

    Sader, Kasim; Reedy, Michael; Popp, David; Lucaveche, Carmen; Trinick, John

    2007-07-01

    Thin sections of biological tissue embedded in plastic and cut with an ultramicrotome do not generally display useful details smaller than approximately 50 A in the electron microscope. However, there is evidence that before sectioning the embedded tissue can be substantially better preserved, which suggests that cutting is when major damage and loss of resolution occurs. We show here a striking example of such damage in embedded insect flight muscle fibres. X-ray diffraction of the embedded muscle gave patterns extending to 13A, whereas sections cut from the same block showed only approximately 50 A resolution. A possible source of this damage is the substantial compression that was imposed on sections during cutting. An oscillating knife ultramicrotome eliminates the compression and it seemed possible that sections cut with such a knife would show substantially improved preservation. We used the oscillating knife to cut sections from the embedded muscle and from embedded catalase crystals. Preservation with and without oscillation was assessed in Fourier transforms of micrographs. Sections cut with the knife oscillating did not show improved preservation over those cut without. Thus compression during cutting does not appear to be the major source of damage in plastic sections, and leaves unexplained the 50 A versus 13A discrepancy between block and section preservation. The results nevertheless suggest that improvements in ultramicrotomy will be important for bringing thin-sectioning and tomography of plastic-embedded cells and tissues to the point where macromolecule shapes can be resolved.

  8. TH-AB-201-01: A Feasibility Study of Independent Dose Verification for CyberKnife

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sato, A; Noda, T; Keduka, Y

    2016-06-15

    Purpose: CyberKnife irradiation is composed of tiny-size, multiple and intensity-modulated beams compared to conventional linacs. Few of the publications for Independent dose calculation verification for CyberKnife have been reported. In this study, we evaluated the feasibility of independent dose verification for CyberKnife treatment as Secondary check. Methods: The followings were measured: test plans using some static and single beams, clinical plans in a phantom and using patient’s CT. 75 patient plans were collected from several treatment sites of brain, lung, liver and bone. In the test plans and the phantom plans, a pinpoint ion-chamber measurement was performed to assess dosemore » deviation for a treatment planning system (TPS) and an independent verification program of Simple MU Analysis (SMU). In the clinical plans, dose deviation between the SMU and the TPS was performed. Results: In test plan, the dose deviations were 3.3±4.5%, and 4.1±4.4% for the TPS and the SMU, respectively. In the phantom measurements for the clinical plans, the dose deviations were −0.2±3.6% for the TPS and −2.3±4.8% for the SMU. In the clinical plans using the patient’s CT, the dose deviations were −3.0±2.1% (Mean±1SD). The systematic difference was partially derived from inverse square law and penumbra calculation. Conclusion: The independent dose calculation for CyberKnife shows −3.0±4.2% (Mean±2SD) and our study, the confidence limit was achieved within 5% of the tolerance level from AAPM task group 114 for non-IMRT treatment. Thus, it may be feasible to use independent dose calculation verification for CyberKnife treatment as the secondary check. This research is partially supported by Japan Agency for Medical Research and Development (AMED)« less

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Y; Liu, B; Liang, B

    Purpose: Current CyberKnife treatment planning system (TPS) provided two dose calculation algorithms: Ray-tracing and Monte Carlo. Ray-tracing algorithm is fast, but less accurate, and also can’t handle irregular fields since a multi-leaf collimator system was recently introduced to CyberKnife M6 system. Monte Carlo method has well-known accuracy, but the current version still takes a long time to finish dose calculations. The purpose of this paper is to develop a GPU-based fast C/S dose engine for CyberKnife system to achieve both accuracy and efficiency. Methods: The TERMA distribution from a poly-energetic source was calculated based on beam’s eye view coordinate system,more » which is GPU friendly and has linear complexity. The dose distribution was then computed by inversely collecting the energy depositions from all TERMA points along 192 collapsed-cone directions. EGSnrc user code was used to pre-calculate energy deposition kernels (EDKs) for a series of mono-energy photons The energy spectrum was reconstructed based on measured tissue maximum ratio (TMR) curve, the TERMA averaged cumulative kernels was then calculated. Beam hardening parameters and intensity profiles were optimized based on measurement data from CyberKnife system. Results: The difference between measured and calculated TMR are less than 1% for all collimators except in the build-up regions. The calculated profiles also showed good agreements with the measured doses within 1% except in the penumbra regions. The developed C/S dose engine was also used to evaluate four clinical CyberKnife treatment plans, the results showed a better dose calculation accuracy than Ray-tracing algorithm compared with Monte Carlo method for heterogeneous cases. For the dose calculation time, it takes about several seconds for one beam depends on collimator size and dose calculation grids. Conclusion: A GPU-based C/S dose engine has been developed for CyberKnife system, which was proven to be efficient and accurate for clinical purpose, and can be easily implemented in TPS.« less

  10. [Randomized controlled trials of needle knife therapy combined with rotation traction manipulation for the treatment of cervical spondylotic radiculopathy].

    PubMed

    Zhou, Zhong-Liang; Su, Guo-Hong; Zheng, Bao-Zhu; Zuo, Yu-Zhu; Wei, Fu-Liang

    2016-09-25

    To compare the therapeutic effects between needle knife therapy combined with rotation traction manipulation and rotation traction manipulation for the treatment of cervical spondylotic radiculopathy. From November 2013 to June 2015, 80 patients with cervical spondylotic radiculopathy meeting the inclusion criteria were divided into two groups randomly:the control group in which 39 patients were treated with rotation traction manipulation, and the treatment group in which 41 patients were treated with needle knife combined with rotation traction manipulation. The patients in the control group were treated once dayly for 2 weeks, which was 1 course. The patients in the treatment group were treated with needle knife firstly once a week for 2 weeks, which was 1 course;then were treated with the same methods as the patients in the control group. The symptoms, signs score and the therapeutic effects of the two groups before and after treatment were observed. After treatment, symptoms and signs scores declined in both groups( P <0.05). The results of the treatment group were better than effects in the control group( P <0.05). In the treatment group, 19 patients got an excellent result, 16 good, 5 fair and 1 bad;while in the control group, 10 patients got an excellent result, 10 good, 16 fair and 3 bad;the results of the treatment group were better than the results of the control group( P <0.01). Needle knife combined with rotation traction manipulation is an effective method for the treatment of cervical spondylotic radiculopathy, which is better than using manipulation method simply. Needle knife therapy has follow advantages:improving local blood circulation, reducing local content of pain substance, increasing production of substances resisting pain, opening channels and collaterals, and make body reaching new static and dynamic balance on the new foundation.

  11. Clinical efficacy of gamma knife and surgery treatment of mesial temporal lobe epilepsy and their effects on EF-Tumt and EF-Tsmt expression.

    PubMed

    Wang, X-Q; Zhang, X-D; Han, Y-M; Shi, X-F; Lan, Z-B; Men, X-X; Pan, Y-W

    2017-04-01

    To study the clinical efficacy of gamma knife and surgery treatment of mesial temporal lobe epilepsy (MTLE) and their effects on EF-Tumt and EF-Tsmt expression. The data of 78 cases of MTLE patients treated in our hospital from April 2011 to March 2013 were retrospectively analyzed. The patients were divided into two groups according to the treatment methods: the surgery group (including 41 cases) and the gamma knife group (including 37 cases). The clinical efficacy, the occurrence and recurrence of complications were evaluated, respectively; meanwhile, the expression of the EF-Tumt protein and EF-Tsmt protein in brain tissue were analyzed. The difference between the efficacy rate of the two groups showed no statistical significance (χ2=0.960, p>0.05). The complication rate of the gamma knife group was significantly lower than that of the control group (χ2=6.430, p<0.05). The recurrence rate of the patients in the gamma knife group was significantly lower than that of the patients in the surgery group (p>0.05). Within the two groups, the positive expression granum of EF-Tsmt protein and EF-Tumt protein of the two groups after treatment were significantly lower than that before treatment (p<0.05). After treatment, the positive expression granum of EF-Tsmt protein of the patients in the gamma knife group was obviously more than that of the patients in the surgery group (p<0.05). The difference between the positive expression granum of EF-Tumt protein of the two groups showed no statistical significance (p>0.05). Before and after treatment within the group, the positive cell of EF-Tsmt protein and EF-Tumt protein of the two groups of patients after treatment were significantly lower than that before treatment (p<0.05). After treatment, the difference between the EF-Tsmt protein positive cell and the EF-Tumt protein positive cell of the two groups of patients showed no statistical significance (p>0.05). Both surgery and gamma knife could treat MTLE effectively, and the efficacy may be related to the ability to reduce the expression of EF-Tsmt protein and EF-Tumt protein in brain tissue.

  12. Clinical Practice Guidelines on the Screening and Treatment of Precancerous Lesions for Cervical Cancer Prevention in Saudi Arabia.

    PubMed

    Al-Mandeel, Hazem Mahmoud; Sagr, Emad; Sait, Khalid; Latifah, Hassan Mohamed; Al-Obaid, Abdulaziz; Al-Badawi, Ismail A; Alkushi, Abdulmohsen O; Salem, Hany; Massoudi, Nada S; Schunemann, Holger; Mustafa, Reem A; Brignardello-Petersen, Romina

    2016-01-01

    Cervical cancer is the third most common gynecological malignancy in Saudi women with an estimated incidence rate of 1.9 cases per 100 000 women-years. More than 40% of cervical cancer cases are diagnosed at advanced stages due to lack of a routine screening program in Saudi Arabia. Thus, national guidelines for routine screening and treatment of precancerous cervical lesions are needed. The Saudi Centre for Evidence-Based Healthcare invited a panel of local experts and partnered them with a team from McMaster University in Canada for methodological support, to develop national clinical practice guidelines on the screening and treatment of precancerous lesions for cervical cancer. After the panel identified key clinical questions, the McMaster University working group updated existing systematic reviews that had been used for the 2013 WHO Guidelines for screening and treatment of precancerous lesions for cervical cancer prevention. Recommendations were based on the GRADE (Grading of Recommendations, Assessment, Development and Evaluation) approach. Those recommendations took into account the available evidence, patient values and preferences, and resource use in the Saudi context. The panel provided recommendations on two major issues: screening for precancerous lesions (cervical intraepithelial neoplasia 2 & 3) and treatment of those lesions to prevent cervical cancer in women who tested positive after screening. The Saudi expert panel recommends using the HPV DNA test followed by colposcopy or cytology (Pap test) followed by colposcopy to screen for CIN2+ in women at risk of cervical cancer. The panel recommends cryotherapy or loop excision electrosurgery procedure (LEEP) over cold knife cone biopsy to treat women at risk of cervical cancer that tests positive for CIN2+. Universal screening for precancerous cervical dysplasia in women in Saudi Arabia is recommended using HPV testing and or cytology. Either cryotherapy or LEEP are preferred for treatment. National studies on cervical cancer screening modalities and treatment of precancerous cervical lesions, including HPV prevalence and its association with cervical cancer, are scarce.

  13. Evaluation and development of integrated technology of rare metal concentrate production in high-level ore processing at Zashikhinsk deposit

    NASA Astrophysics Data System (ADS)

    Khokhulya, MS; Mukhina, TN; Ivanova, V. A.; Mitrofanova, G. V.; Fomin, A. V.; Sokolov, VD

    2017-02-01

    The authors discuss material constitution of columbite ore sample and recommend optimized pretreatment modes to obtain ball milling products at the maximum dissociation of ore minerals in aggregates. A concentration technology is proposed, with division of material into two flows -0.315 mm and -0.2 mm in sizes, generated in the milling and screening cycles and subjected to gravity-magnetic and magnetic-gravity treatment, respectively. It is shown that the technology ensures production of both tantalum-niobium and zircon concentrates. It has become possible to additionally recover rare metal components Nb2O5 and ZrO2 from tailings through flotation.

  14. Radiosurgery with the world's first fully robotized Leksell Gamma Knife PerfeXion in clinical use: a 200-patient prospective, randomized, controlled comparison with the Gamma Knife 4C.

    PubMed

    Régis, Jean; Tamura, Manabu; Guillot, Cécile; Yomo, Shoji; Muraciolle, Xavier; Nagaje, Mariko; Arka, Yasser; Porcheron, Denis

    2009-02-01

    The world's first Leksell Gamma Knife PerfeXion (Elekta Instrument AB, Stockholm, Sweden) for radiosurgery of the head and neck became operational at Timone University Hospital in Marseille on July 10, 2006. To allow strict evaluation of the capabilities, advantages, disadvantages, and limitations of this new technology, patients were enrolled in a prospective, randomized trial. In 66 working days, between July 10 and December 20, 2006, 363 patients were treated by gamma knife surgery at Timone University Hospital, Marseille. Of these patients, 200 were eligible for the comparative prospective study (inclusion criteria were informed consent obtained, tumor or vascular indication, and no previous radiosurgery or radiotherapy). In accordance with the blinded randomization process, 100 patients were treated with the Leksell Gamma Knife 4C (Elekta Instrument AB) and Gamma Knife 100 (Elekta Instrument AB) with the Leksell Gamma Knife PerfeXion. Dose planning parameters, dosimetry measurements on the patient's body, workflow, patient comfort, quality assurance procedure, and a series of other treatment-related parameters were systematically and prospectively evaluated in both arms of the trial. No technical failure of the treatment procedure was encountered. The new dose-planning system led to the use of composite shots in 39.4% of the patients. The median number of different collimator sizes used was larger with the PerfeXion than with the 4C (2 and 1, respectively). The mean number of isocenters used was lower (10.67 and 13.08, respectively). The median total treatment time was significantly shorter with the PerfeXion (40 and 60 minutes, respectively), but there was no significant difference in the median radiation time (34.02 and 33.40 minutes, respectively). The procedure was performed using only a single run in 98.99% of the PerfeXion cases and in 42% of the 4C cases. Collision risk on the 4C forced us to change the frame gamma angle for at least 1 shot in 24% of the patients and led to treatment in manual mode for at least 1 shot in 21% of the patients. Collision risk requiring technical adaptation did not occur with the PerfeXion. In 1 patient treated with the PerfeXion, the system required a direct collision check. In terms of dose to structures outside the target area, the PerfeXion delivers 8.2 times less to the vertex, 10 times less to the thyroid, 12.9 times less to the sternum, and 15 times less to the gonads. Our prospective study indicates that procedures with the PerfeXion were collision-free, even with very eccentric lesions (e.g., multiple metastases). The duration of the surgical procedure, the amount of time required for nurse, physicist, and physician intervention on the machine, and the duration of the quality assurance procedure were all shown to be dramatically reduced with the PerfeXion gamma knife. Patient protection is greatly improved with the PerfeXion. In our experience, the technological advances of the Leksell Gamma Knife PerfeXion will make a very significant contribution to future progress in head and neck radiosurgery.

  15. Study of extraterrestrial disposal of radioactive wastes. Part 2: Preliminary feasibility screening study of extraterrestrial disposal of radioactive wastes in concentrations, matrix materials, and containers designed for storage on earth

    NASA Technical Reports Server (NTRS)

    Hyland, R. E.; Wohl, M. L.; Thompson, R. L.; Finnegan, P. M.

    1972-01-01

    The results are reported of a preliminary feasibility screening study for providing long-term solutions to the problems of handling and managing radioactive wastes by extraterrestrial transportation of the wastes. Matrix materials and containers are discussed along with payloads, costs, and destinations for candidate space vehicles. The conclusions reached are: (1) Matrix material such as spray melt can be used without exceeding temperature limits of the matrix. (2) The cost in mills per kw hr electric, of space disposal of fission products is 4, 5, and 28 mills per kw hr for earth escape, solar orbit, and solar escape, respectively. (3) A major factor effecting cost is the earth storage time. Based on a normal operating condition design for solar escape, a storage time of more than sixty years is required to make the space disposal charge less than 10% of the bus-bar electric cost. (4) Based on a 10 year earth storage without further processing, the number of shuttle launches required would exceed one per day.

  16. Criminal Acts against Civil Aviation, 1986

    DTIC Science & Technology

    1986-01-01

    AS/Auckland, NZ I M AA Knife & Alleged UnknownPol Explosive Asylu 06-11-79 Delta L-1011 New York/Ft. Lauder . 1 M S Knife & Alleged Cuba Gun 06-20-79...India Lahore/Prisoner Release/ Money 07-21-84 MEA B-707 Abu Dhabi, UAE/Beirut, Lebanon Abu Dhabi, UAE 07-29-84 Aeropostal DC-9 Caracas/Curacao

  17. Past, Present and Future. Dull Knife Memorial College (Indian Action Program Inc.).

    ERIC Educational Resources Information Center

    1978

    Five vocational training programs as well as academic coursework are offered on the Northern Cheyenne Reservation by Dull Knife Memorial College. Established and operated by the Northern Cheyenne, and located in Lame Deer, Montana, the college was chartered by a tribal ordinance in 1975. Approximately 75 trainees are currently involved in the…

  18. Chief Dull Knife Community Is Strengthening the Northern Cheyenne Language and Culture.

    ERIC Educational Resources Information Center

    Littlebear, Richard E.

    2003-01-01

    Language revitalization programs should focus on whether they want to teach the language, teach about the language, teach with the language, or teach the language for academic credit. A program at Chief Dull Knife College (Montana) teaches the Cheyenne language using the Total Physical Response method, which replicates the manner in which first…

  19. Some observations on glass-knife making.

    PubMed

    Ward, R T

    1977-11-01

    The yield of usable knife edge per knife (for thin sectioning) was markedly increased when glass knives were made at an included angle of 55 degrees rather than the customary 45 degrees. A large number of measurements of edge check marks made with a routine light scattering method as well as observations made on a smaller number of test sections with the electron microscope indicated the superiority of 55 degrees knives. Knives were made with both taped pliers and an LKB Knifemaker. Knives were graded by methods easily applied in any biological electron microscope laboratory. Depending on the mode of fracture, the yield of knives having more than 33% of their edges free of check marks was 30 to 100 times greater at 55 degrees than 45 degrees.

  20. [Treatment of trigger finger with located needle knife].

    PubMed

    Zhang, Qi-Feng; Yang, Jiang; Xi, Sheng-Hua

    2016-07-25

    To investigate the clinical effects of located needle knife in the treatment of trigger finger. The clinical data of 133 patients(145 fingers) with trigger finger underwent treatment with located needle knife from September 2010 to March 2014 were retrospectively analyzed. There were 37 males(40 fingers) and 96 females (105 fingers), aged from 18 to 71 years old with a mean of 51.8 years. Course of disease was from 1 to 19 months with an average of 8.2 months. Affected fingers included 82 thumbs, 12 index fingers, 11 middle fingers, 36 ring fingers, and 4 little fingers. According to the standard of Quinnell grade, 42 fingers were grade III, 92 fingers were grade IV, and 11 fingers were grade V. Firstly the double pipe gab was put into the distal edge of hypertrophic tendon sheath, then small knife needle was used to release the sheath proximally along the tendon line direction. The informations of wound healing and nerve injury, postoperative finger function, finger pain at 6 months were observed. The operation time was from 8 to 25 min with an average of 9.8 min. All the patients were followed up from 6 to 26 months with an average of 12.5 months. No complications such as the wound inflammation and seepage, vascular or nerve injuries were found. According to the standard of Quinnell grade, 123 fingers got excellent results, 15 good, 7 poor. It's a good choice to treat trigger finger with located needle knife in advantage of minimal invasion, simple safe operation, and it should be promoted in clinic.

  1. Gamma Knife treatment of low-grade gliomas in children.

    PubMed

    Ekşi, Murat Şakir; Yılmaz, Baran; Akakın, Akın; Toktaş, Zafer Orkun; Kaur, Ahmet Cemil; Demir, Mustafa Kemal; Kılıç, Türker

    2015-11-01

    Low-grade gliomas have good overall survival rates in pediatric patients compared to adults. There are some case series that reported the effectiveness and safety of Gamma Knife radiosurgery, yet they are limited in number of patients. We aimed to review the relevant literature for pediatric low-grade glial tumors treated with stereotactic radiosurgery, specifically Gamma Knife radiosurgery, and to present an exemplary case. A 6-year-old boy was admitted to clinic due to head trauma. He was alert, cooperative, and had no obvious motor or sensorial deficit. A head CT scan depicted a hypodense zone at the right caudate nucleus. The brain magnetic resonance imaging (MRI) depicted a mass lesion at the same location. A stereotactic biopsy was performed. Histopathological diagnosis was low-grade astrocytoma (grade II, World Health Organization (WHO) classification, 2007). Gamma Knife radiosurgery was applied to the tumor bed. Tumor volume was 21.85 cm(3). Fourteen gray was given to 50% isodose segment of the lesion (maximal dose of 28 Gy). The tumor has disappeared totally in 4 months, and the patient was tumor-free 21 months after the initial treatment. The presented literature review represents mostly single-center experiences with different patient and treatment characteristics. Accordingly, a mean/median margin dose of 11.3-15 Gy with Gamma Knife radiosurgery (GKRS) is successful in treatment of pediatric and adult low-grade glial tumor patients. However, prospective studies with a large cohort of pediatric patients should be conducted to make a more comprehensive conclusion for effectiveness and safety of GKRS in pediatric low-grade glial tumors.

  2. Mechanochemical destruction of mirex co-ground with iron and quartz in a planetary ball mill.

    PubMed

    Yu, Yunfei; Huang, Jun; Zhang, Wang; Zhang, Kunlun; Deng, Shubo; Yu, Gang

    2013-02-01

    Mechanochemical destruction (MCD) has been recognized as a promising non-combustion technology for the disposal of obsolete pesticides belonging to the persistent organic pollutants (POPs). Mirex, a termiticide ever used for many years in China, was ball milled in the presence of various reagent(s) in a planetary ball mill at room temperature to investigate the destruction efficiency. The ground samples were characterized and analyzed by Fourier transform infrared spectroscopy (FTIR), Raman spectroscopy, gas chromatography (GC), and ion chromatography (Martins, Bicego et al.). Under the same conditions of mill rotary rate and charge ratio, the mixture of iron powder and quartz sand (Fe/SiO(2)) was found best in promoting the mirex destruction. Mirex was completed destroyed after 2 h grinding at a charge ratio of 36:1 (reagent/mirex, m/m) and a mill rotation speed of 550 rpm. No organic compound was detected by GC/μECD screening. The yield of water-soluble chlorine determined by ion chromatography (Martins, Bicego et al.) in the final residue accounted for 90.7% of chlorine in the original mirex, which indicated a nearly complete dechlorination. Signals of both graphite and amorphous carbon were found in the Raman spectra of the co-ground powder samples. With the main final degradation products of water soluble Cl and carbon, the mechanism of the mechanochemical destruction approach should be dechlorination followed by the carbonization. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. A cross sectional review of patient information available in the World Wide Web on CyberKnife: fallacies and pitfalls.

    PubMed

    Menon, Durgapoorna; Chelakkot, Prameela G; Sunil, Devika; Lakshmaiah, Ashwini

    2017-12-01

    The purpose of this study is to assess the quality of videos available in YouTube on CyberKnife. The term "CyberKnife" was input into the search window of www.youtube.com on a specific date and the first 50 videos were assessed for technical and content issues. The data was tabulated and analysed. The search yielded 32,300 videos in 0.33 s. Among the first 50 analysed, most were professional videos, mostly on CyberKnife in general and for brain tumours. Most of the videos did not mention anything about patient selection or lesion size. The other technical details were covered by most although they seemed muffled by the animations. Many patient videos were recordings of one entire treatment, thus giving future patients an insight on what to expect. Almost half the videos projected glorified views about the treatment technique. The company videos were reasonably accurate and well presented as were many institutional videos, although there was a tendency to gloss over a few points. The glorification of the treatment technique was a disturbing finding. The profound trust of the patients on the health care system is humbling.

  4. [Use of esophageal small balloon or papillary sphincter knife in the treatment of stent implantation 
for colorectal malignant obstruction].

    PubMed

    Xiao, Dinghua; Liu, Shaojun; Yan, Hanguang; Wang, Xiaoyan

    2018-05-28

    To explore the function of esophageal small balloon or papillary sphincter knife in the treatment of stent implantation for colorectal malignant obstruction, and to improve the success rate of colonic stent placement in such patients.
 Methods: A total of 49 patients with colorectal cancer complicated with almost complete obstruction or colorectal cancer were enrolled for this study. The esophageal small balloon or papillary sphincter knife was used in the guide wires. The guide wires gradually crossed the tumor gap and they were placed in the contralateral intestinal cavity with balloon progression. X-ray was then used to confirm whether the guide wire was inserted in the lesion intestinal cavity, and then the metal bare stent was inserted.
 Results: The guide wires was successfully inserted with conventional methods in these 49 cases, while they were also successfully placed the guide wire and the stent in the new way.
 Conclusion: For the patients with colorectal cancer complicated with complete obstruction or colorectal cancer located in obviously angled location, the use of esophageal small balloon or papillary sphincter knife can help the guide wire insert. They greatly improve the success rate of stent implantation.

  5. Shot sequencing based on biological equivalent dose considerations for multiple isocenter Gamma Knife radiosurgery.

    PubMed

    Ma, Lijun; Lee, Letitia; Barani, Igor; Hwang, Andrew; Fogh, Shannon; Nakamura, Jean; McDermott, Michael; Sneed, Penny; Larson, David A; Sahgal, Arjun

    2011-11-21

    Rapid delivery of multiple shots or isocenters is one of the hallmarks of Gamma Knife radiosurgery. In this study, we investigated whether the temporal order of shots delivered with Gamma Knife Perfexion would significantly influence the biological equivalent dose for complex multi-isocenter treatments. Twenty single-target cases were selected for analysis. For each case, 3D dose matrices of individual shots were extracted and single-fraction equivalent uniform dose (sEUD) values were determined for all possible shot delivery sequences, corresponding to different patterns of temporal dose delivery within the target. We found significant variations in the sEUD values among these sequences exceeding 15% for certain cases. However, the sequences for the actual treatment delivery were found to agree (<3%) and to correlate (R² = 0.98) excellently with the sequences yielding the maximum sEUD values for all studied cases. This result is applicable for both fast and slow growing tumors with α/β values of 2 to 20 according to the linear-quadratic model. In conclusion, despite large potential variations in different shot sequences for multi-isocenter Gamma Knife treatments, current clinical delivery sequences exhibited consistent biological target dosing that approached that maximally achievable for all studied cases.

  6. Evanescent-Wave Filtering in Images Using Remote Terahertz Structured Illumination

    NASA Astrophysics Data System (ADS)

    Flammini, M.; Pontecorvo, E.; Giliberti, V.; Rizza, C.; Ciattoni, A.; Ortolani, M.; DelRe, E.

    2017-11-01

    Imaging with structured illumination allows for the retrieval of subwavelength features of an object by conversion of evanescent waves into propagating waves. In conditions in which the object plane and the structured-illumination plane do not coincide, this conversion process is subject to progressive filtering of the components with high spatial frequency when the distance between the two planes increases, until the diffraction-limited lateral resolution is restored when the distance exceeds the extension of evanescent waves. We study the progressive filtering of evanescent waves by developing a remote super-resolution terahertz imaging system operating at a wavelength λ =1.00 mm , based on a freestanding knife edge and a reflective confocal terahertz microscope. In the images recorded with increasing knife-edge-to-object-plane distance, we observe the transition from a super-resolution of λ /17 ≃60 μ m to the diffraction-limited lateral resolution of Δ x ≃λ expected for our confocal microscope. The extreme nonparaxial conditions are analyzed in detail, exploiting the fact that, in the terahertz frequency range, the knife edge can be positioned at a variable subwavelength distance from the object plane. Electromagnetic simulations of radiation scattering by the knife edge reproduce the experimental super-resolution achieved.

  7. Does wastewater from olive mills induce toxicity and water repellency in soil?

    NASA Astrophysics Data System (ADS)

    Peikert, B.; Bandow, N.; Schaumann, G. E.

    2012-04-01

    Olive oil mill wastewater is the effluent generated by the olive oil extraction process. It is the main waste product of this industry mainly being produced in the Mediterranean Basin. Because proper treatment options are rare it is often disposed into the environment, e.g. fields or wadies. Due to its high concentration of fatty acids and phytotoxic phenolic compounds and its high chemical and biological oxygen demand, olive oil mill wastewater becomes a serious environmental problem. In this screening study we investigated long-term effects of olive oil mill wastewater application on soil properties in several locations in the West Bank and Israel. We determined wettability via water drop penetration time and the contact angle as well as general soil properties including pH, EC, carbon content, and we conducted thermogravimetrical analyses in order to characterize the impact of the waste water on the quality of soil organic matter. Our results show that application of olive oil mill wastewater has various effects. We determined contact angles between 110 and 120° and water drop penetration times up to 1367 s indicating significant reduction in wettability. Furthermore, soil carbon and nitrogen content and water extractable organic matter increased as well as electric conductivity, which could be pointed out as a fertilizing effect. In contrast soil pH was significantly reduced. Conducting thermal analyses we observed an increase in the labile and refractory carbon fraction. Probably first one is responsible for induced water repellency. As a consequence the reduced wettability negatively affects soil quality. It would therefore be promising to minimize the hydrophobizing impacts without losing fertilizing effects of the olive oil mill wastewater.

  8. Bioluminescence inhibition assays for toxicity screening of wood extractives and biocides in paper mill process waters.

    PubMed

    Rigol, Anna; Latorre, Anna; Lacorte, Sílvia; Barceló, Damià

    2004-02-01

    The risk associated with wood extractives, biocides, and other additives in pulp and paper mill effluents was evaluated by performing a characterization of process waters and effluents in terms of toxicity and chemical analysis. The individual toxicity of 10 resin acids, two unsaturated fatty acids, and three biocides was estimated by measuring the bioluminescence inhibition with a ToxAlert 100 system. Median effective concentration values (EC50) of 4.3 to 17.9, 1.2 to 1.5, and 0.022 to 0.50 mg/L were obtained, respectively. Mixtures of these three families of compounds showed antagonistic effects. Chemical analysis of process waters was performed by liquid chromatography- and gas chromatography-mass spectrometry. Biocides such as 2-(thiocyanomethylthio)-benzotiazole (TCMTB) (EC50 = 0.022 mg/L) and 2,2-dibromo-3-nitrilpropionamide (DBNPA) (EC50 = 0.50 mg/L) were the most toxic compounds tested and were detected at concentrations of 16 and 59 microg/L, respectively, in a closed-circuit recycling paper mill. Process waters from kraft pulp mills, printing paper mills, and packing board paper mills showed the highest concentration of resin acids (up to 400 microg/L) and accounted for inhibition percentages up to 100%. Detergent degradation products such as nonylphenol (NP) and octylphenol (OP) and the plasticizer bisphenol A (BPA) were also detected in the waters at levels of 0.6 to 10.6, 0.3 to 1.4, and 0.7 to 187 microg/L, respectively. However, once these waters were biologically treated, the concentration of detected organic compounds diminished and the toxicity decreased in most cases to values of inhibition lower than 20%.

  9. Friction and wear of sintered fiber-metal abradable seal materials

    NASA Technical Reports Server (NTRS)

    Bill, R. C.; Shiembob, L. T.

    1977-01-01

    Three abradable gas path seal material systems based on a sintered NiCrAlY fibermetal structure were evaluated under a range of wear conditions representative of those likely to be encountered in various knife-edge seal (labyrinth or shrouded turbine) applications. Conditions leading to undesirable wear of the rotating knife were identified and a model was proposed based on thermal effects arising under different rub conditions. It was found, and predicted by the model, that low incursion (plunge) rates tended to promote smearing of the low density sintered material with consequent wear to the knife-edge. Tradeoffs benefits between baseline 19 percent dense material, a similar material of increased density, and a self lubricating coating applied to the 19 percent material were identified based on relative rub tolerance and erosion resistance.

  10. P11.10 Role of hydroxyurea as an adjuvant treatment after gamma knife radiosurgery for atypical (WHO grade II) meningiomas

    PubMed Central

    Abdel Karim, K.; El Shehaby, A.; Emad, R.; Reda, W.; El Mahdy, M.; Ghali, R.; Nabeel, A.

    2016-01-01

    Abstract Objective: The use of gamma knife radiosurgery in the treatment of atypical (WHO grade II) meningiomas has been reported in the past with highly variable degrees of success. The use of hydroxyurea as a radiation sensitizer as well as salvage chemotherapy in cancer patients is well established and was also used for treatment of recurrent and malignant meningiomas. In this study we investigated the effect of hydroxyurea administration after gamma knife radiosurgery for atypical (grade II) meningiomas on local tumor control and patient survival. Patients and methods: Between November 2008 and April 2014, thirty-five patients with pathologically proven atypical meningiomas were treated by gamma knife radiosurgery. We excluded patients who had received previous external beam radiotherapy. Twenty-three patients were given hydroxyurea after gamma knife treatment. The rest of the patients refused to take the treatment or were incompliant (were not included in the study). Of these 23, nineteen patients harboring 20 tumors were available for radiological and clinical follow up for a minimum of 2 years. Four patients were lost from follow up. Twenty tumors underwent 26 gamma knife procedures. Five tumors underwent staged treatment. The tumor volume was 0.6–38.3 cc (median 12.7 cc). The prescription dose/session ranged from 10 to 16 Gy (mean 14 Gy). The patients received a course of hydroxyurea (1000 mg/day) for one year after gamma knife treatment. The mean follow up period was 43 months (14–76 months). Results: Tumor control was achieved in 18 out of 20 tumors where 15 tumors shrank and 3 tumors remained stable with a tumor control rate of 90%. Tumor progression occurred in 2 patients (at 14 and 15 months). Transient edema was observed with 6 tumors which was temporary, and no G3 or G4 myelosuppression were recorded. Two patients died from progression of other tumors not included in the study after 3 and 6 years. Distant tumor progression (in another intracranial location or outside the radiation field) was observed in 5 patients. In 3 patients new tumors developed at the edge of previous craniotomy, in one patient tumor progression occurred after receiving radiosurgery alone for another lesion after the end of adjuvant treatment and in one patient progression occurred in an untreated tumor that was under observation. The actuarial progression free survival and overall survival at 3 years were 89.5% and 94% respectively. Conclusion: Preliminary results suggest good tumor control and shrinkage of atypical (grade II) meningiomas treated with Gamma Knife radiosurgery followed by one year of adjuvant hydroxyurea. Further larger randomized and double-arm studies are required to confirm the potential role of hydroxyurea in those tumors.

  11. Effect of amphiphilic additives on the behavior of water-based acrylic pressure-sensitive adhesives during paper recycling

    Treesearch

    Jihui Guo; Steven J. Severtson; Larry E. Gwin; Carl J. Houtman

    2008-01-01

    Pressure-sensitive adhesives (PSAs) in recovered paper reduce efficiency and increase operating costs for paper recycling mills. Increased PSA fragmentation during pulping and the corresponding reduction in screening efficiency are indications that a PSA will likely interfere with paper recycling. Water-based PSAs, which dominate the label market, have complex...

  12. An automatic gore panel mapping system

    NASA Technical Reports Server (NTRS)

    Shiver, John D.; Phelps, Norman N.

    1990-01-01

    The Automatic Gore Mapping System is being developed to reduce the time and labor costs associated with manufacturing the External Tank. The present chem-milling processes and procedures are discussed. The down loading of the simulation of the system has to be performed to verify that the simulation package will translate the simulation code into robot code. Also a simulation of this system has to be programmed for a gantry robot instead of the articulating robot that is presently in the system. It was discovered using the simulation package that the articulation robot cannot reach all the point on some of the panels, therefore when the system is ready for production, a gantry robot will be used. Also a hydrosensor system is being developed to replace the point-to-point contact probe. The hydrosensor will allow the robot to perform a non-contact continuous scan of the panel. It will also provide a faster scan of the panel because it will eliminate the in-and-out movement required for the present end effector. The system software is currently being modified so that the hydrosensor will work with the system. The hydrosensor consists of a Krautkramer-Branson transducer encased in a plexiglass nozzle. The water stream pumped through the nozzle is the couplant for the probe. Also, software is being written so that the robot will have the ability to draw the contour lines on the panel displaying the out-of-tolerance regions. Presently the contour lines can only be displayed on the computer screens. Research is also being performed on improving and automating the method of scribing the panels. Presently the panels are manually scribed with a sharp knife. The use of a low power laser or water jet is being studied as a method of scribing the panels. The contour drawing pen will be replaced with scribing tool and the robot will then move along the contour lines. With these developments the Automatic Gore Mapping Systems will provide a reduction in time and labor costs associated with manufacturing the External Task. The system also has the potential of inspecting other manufactured parts.

  13. Making Do with What We Have: Use Your Bootstraps

    ERIC Educational Resources Information Center

    Calmettes, Guillaume; Drummond, Gordon B.; Vowler, Sarah L.

    2012-01-01

    A jack knife is a pocket knife that is put to many tasks, because it's ready to hand. Often there could be a better tool for the job, such as a screwdriver, a scraper, or a can-opener, but these are not usually pocket items. In statistical terms, the expression implies making do with what's available. Another simile, of an extreme situation, is…

  14. Knife blade as a facial foreign body.

    PubMed

    Gardner, P A; Righi, P; Shahbahrami, P B

    1997-08-01

    This case demonstrates the unpredictability of foreign bodies in the face. The retained knife blade eluded detection on two separate examinations. The essential components to making a correct diagnosis of a foreign body following a stabbing to the face include a thorough review of the mechanism of injury, a complete head and neck examination, a high index of suspicion, and plain radiographs of the face.

  15. 46 CFR 160.051-9 - Equipment required for Coastal Service inflatable liferafts.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... line as described in § 160.151-21(a). (b) Knife. One knife, of a type designed to minimize the chance... anchor as described in § 160.151-21(e). (f) Paddles. Two paddles of the same size and type as used to... as described in § 160.151-21(i) of this part. (h) Flashlight. One flashlight with spare batteries as...

  16. 46 CFR 160.051-11 - Equipment required for Coastal Service inflatable liferafts.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... line as described in § 160.151-21(a). (b) Knife. One knife, of a type designed to minimize the chance... anchor as described in § 160.151-21(e). (f) Paddles. Two paddles of the same size and type as used to...-21(i) of this part. (h) Flashlight. One flashlight with spare batteries as described in § 160.151-21...

  17. 46 CFR 160.051-11 - Equipment required for Coastal Service inflatable liferafts.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... line as described in § 160.151-21(a). (b) Knife. One knife, of a type designed to minimize the chance... anchor as described in § 160.151-21(e). (f) Paddles. Two paddles of the same size and type as used to...-21(i) of this part. (h) Flashlight. One flashlight with spare batteries as described in § 160.151-21...

  18. The Effects of Swedish Knife Model on Students' Understanding of the Digestive System

    ERIC Educational Resources Information Center

    Cerrah Ozsevgec, Lale; Artun, Huseyin; Unal, Melike

    2012-01-01

    This study was designed to examine the effect of Swedish Knife Model on students' understanding of digestive system. A simple experimental design (pretest-treatment-posttest) was used in the study and internal comparison of the results of the one group was made. The sample consisted of 40 7th grade Turkish students whose ages range from 13 to 15.…

  19. Is the lateral jack-knife position responsible for cases of transient neurapraxia?

    PubMed

    Molinares, Diana Margarita; Davis, Timothy T; Fung, Daniel A; Liu, John Chung-Liang; Clark, Stephen; Daily, David; Mok, James M

    2016-01-01

    The lateral jack-knife position is often used during transpsoas surgery to improve access to the spine. Postoperative neurological signs and symptoms are very common after such procedures, and the mechanism is not adequately understood. The objective of this study is to assess if the lateral jack-knife position alone can cause neurapraxia. This study compares neurological status at baseline and after positioning in the 25° right lateral jack-knife (RLJK) and the right lateral decubitus (RLD) position. Fifty healthy volunteers, ages 21 to 35, were randomly assigned to one of 2 groups: Group A (RLD) and Group B (RLJK). Motor and sensory testing was performed prior to positioning. Subjects were placed in the RLD or RLJK position, according to group assignment, for 60 minutes. Motor testing was performed immediately after this 60-minute period and again 60 minutes thereafter. Sensory testing was performed immediately after the 60-minute period and every 15 minutes thereafter, for a total of 5 times. Motor testing was performed by a physical therapist who was blinded to group assignment. A follow-up call was made 7 days after the positioning sessions. Motor deficits were observed in the nondependent lower limb in 100% of the subjects in Group B, and no motor deficits were seen in Group A. Statistically significant differences (p < 0.05) were found between the 2 groups with respect to the performance on the 10-repetition maximum test immediately immediately and 60 minutes after positioning. Subjects in Group B had a 10%-70% (average 34.8%) decrease in knee extension strength and 20%-80% (average 43%) decrease in hip flexion strength in the nondependent limb. Sensory abnormalities were observed in the nondependent lower limb in 98% of the subjects in Group B. Thirty-six percent of the Group B subjects still exhibited sensory deficits after the 60-minute recovery period. No symptoms were reported by any subject during the follow-up calls 7 days after positioning. Twenty-five degrees of right lateral jack-knife positioning for 60 minutes results in neurapraxia of the nondependent lower extremity. Our results support the hypothesis that jack-knife positioning alone can cause postoperative neurological symptoms.

  20. Determination of small field synthetic single-crystal diamond detector correction factors for CyberKnife, Leksell Gamma Knife Perfexion and linear accelerator.

    PubMed

    Veselsky, T; Novotny, J; Pastykova, V; Koniarova, I

    2017-12-01

    The aim of this study was to determine small field correction factors for a synthetic single-crystal diamond detector (PTW microDiamond) for routine use in clinical dosimetric measurements. Correction factors following small field Alfonso formalism were calculated by comparison of PTW microDiamond measured ratio M Qclin fclin /M Qmsr fmsr with Monte Carlo (MC) based field output factors Ω Qclin,Qmsr fclin,fmsr determined using Dosimetry Diode E or with MC simulation itself. Diode measurements were used for the CyberKnife and Varian Clinac 2100C/D linear accelerator. PTW microDiamond correction factors for Leksell Gamma Knife (LGK) were derived using MC simulated reference values from the manufacturer. PTW microDiamond correction factors for CyberKnife field sizes 25-5 mm were mostly smaller than 1% (except for 2.9% for 5 mm Iris field and 1.4% for 7.5 mm fixed cone field). The correction of 0.1% and 2.0% for 8 mm and 4 mm collimators, respectively, needed to be applied to PTW microDiamond measurements for LGK Perfexion. Finally, PTW microDiamond M Qclin fclin /M Qmsr fmsr for the linear accelerator varied from MC corrected Dosimetry Diode data by less than 0.5% (except for 1 × 1 cm 2 field size with 1.3% deviation). Regarding low resulting correction factor values, the PTW microDiamond detector may be considered an almost ideal tool for relative small field dosimetry in a large variety of stereotactic and radiosurgery treatment devices. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  1. SU-F-T-538: CyberKnife with MLC for Treatment of Large Volume Tumors: A Feasibility Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bichay, T; Mayville, A

    2016-06-15

    Purpose: CyberKnife is a well-documented modality for SRS and SBRT treatments. Typical tumors are small and 1–5 fractions are usually used. We determined the feasibility of using CyberKnife, with an InCise multileaf collimator option, for larger tumors undergoing standard dose and fractionation. The intent was to understand the limitation of using this modality for other external beam radiation treatments. Methods: Five tumors from different anatomical sites with volumes from 127.8 cc to 1,320.5 cc were contoured and planned on a Multiplan V5.1 workstation. The target average diameter ranged from 7 cm to 13 cm. The dose fractionation was 1.8–2.0 Gy/fractionmore » and 25–45 fractions for total doses of 45–81 Gy. The sites planned were: pancreas, head and neck, prostate, anal, and esophagus. The plans were optimized to meet conventional dose constraints based on various RTOG protocols for conventional fractionation. Results: The Multiplan treatment planning system successfully generated clinically acceptable plans for all sites studied. The resulting dose distributions achieved reasonable target coverage, all greater than 95%, and satisfactory normal tissue sparing. Treatment times ranged from 9 minutes to 38 minutes, the longest being a head and neck plan with dual targets receiving different doses and with multiple adjacent critical structures. Conclusion: CyberKnife, with the InCise multileaf collimation option, can achieve acceptable dose distributions in large volume tumors treated with conventional dose and fractionation. Although treatment times are greater than conventional accelerator time; target coverage and dose to critical structures can be kept within a clinically acceptable range. While time limitations exist, when necessary CyberKnife can provide an alternative to traditional treatment modalities for large volume tumors.« less

  2. The effect of finish line preparation and layer thickness on the failure load and fractography of ZrO2 copings.

    PubMed

    Reich, Sven; Petschelt, Anselm; Lohbauer, Ulrich

    2008-05-01

    To prevent tooth weakening or pulp irritation, there is a need for a minimally invasive method of preparing single anterior crowns. Restoration dimensions for reduced coping thicknesses or less invasive finish line preparations are required. The purposed of this in vitro was to study investigate the fracture performance of high-strength zirconia copings, compare knife-edge margins with chamfer finish lines, and examine the effect of reducing the layer thickness from 0.5 mm to 0.3 mm. Y-TZP zirconia copings were manufactured on brass dies of a maxillary central incisor. Forty copings, with 2 layer thicknesses (0.5 and 0.3 mm), and 2 finish line preparations (knife edge and chamfer; n=10) were cemented using a conventional glass ionomer cement and stored in distilled water at 37 degrees C for 24 hours. The copings were vertically loaded until fracture using a universal testing machine. Data were analyzed by 2-way ANOVA (alpha=.05). Fractographic examination was performed using scanning electron microscopy and confocal laser scanning microscopy. A significantly higher mean failure load was measured for knife-edge (0.5 mm, 1110 +/-175 N; 0.3 mm, 730 +/-160 N) versus chamfer (0.5 mm, 697 +/-126 N; 0.3 mm, 455 +/-79 N) preparations (P<.001), and for 0.5-mm versus 0.3-mm thickness layers (P<.001). Knife-edge preparations present a promising alternative to chamfer finish lines; the fracture load required for knife-edge preparations was 38% greater than that required for chamfer preparations, regardless of coping thickness. Reducing the thickness of a single crown coping from 0.5 to 0.3 mm resulted in a 35% reduction in fracture load required for either preparation type.

  3. Effects of a topical anaesthetic formulation and systemic carprofen, given singly or in combination, on the cortisol and behavioural responses of Merino lambs to castration.

    PubMed

    Paull, D R; Lee, C; Colditz, I G; Fisher, A D

    2009-06-01

    To determine the effectiveness of a topical anaesthetic formulation (Tri-Solfen) with or without the administration of a non-steroidal anti-inflammatory drug (carprofen) on the pain and distress response associated with ring or surgical castration of ram lambs. Merino ram lambs (n = 78) were allocated to 10 treatment groups: 4 groups of knife-castrated lambs and 4 groups of ring-castrated lambs received carprofen (4 mg/kg SC) and Tri-Solfen; 2 control groups (sham) received carprofen at 0 or 4 mg/kg SC. Measurements included plasma cortisol and haptoglobin concentrations, haematology, and behaviour, including posture. Knife-castrated lambs had higher peak cortisol and integrated cortisol responses for the first 6 h after treatment and greater concentration s of circulating acute phase proteins than ring-castrated lambs, both of which were significantly different from the sham controls. Tri-Solfen applied to the knife castration wound significantly reduced both the peak plasma cortisol concentration and the integrated cortisol response for the first 6 h and improved lying behaviour in the first 12 h. Carprofen reduced the cortisol response to knife castration at 30 min, but elevated the cortisol responses at 24 and 48 h. Carprofen nearly halved the number of acute pain behaviours associated with ring castration. There were no significant additive or synergistic effects from combining the analgesic treatments. Tri-Solfen applied to the tail wound provided no detectible benefits during ring castration + tail docking. The physiological and behavioural responses suggest that ring castration has less impact on the lamb than knife castration. The specific analgesic treatments can provide modest amelioration of the pain and discomfort associated with castration. Alternative doses or application methods may enhance their efficacy.

  4. Multicenter evaluation of a synthetic single-crystal diamond detector for CyberKnife small field size output factors.

    PubMed

    Russo, Serenella; Masi, Laura; Francescon, Paolo; Frassanito, Maria Cristina; Fumagalli, Maria Luisa; Marinelli, Marco; Falco, Maria Daniela; Martinotti, Anna Stefania; Pimpinella, Maria; Reggiori, Giacomo; Verona Rinati, Gianluca; Vigorito, Sabrina; Mancosu, Pietro

    2016-04-01

    The aim of the present work was to evaluate small field size output factors (OFs) using the latest diamond detector commercially available, PTW-60019 microDiamond, over different CyberKnife systems. OFs were measured also by silicon detectors routinely used by each center, considered as reference. Five Italian CyberKnife centers performed OFs measurements for field sizes ranging from 5 to 60mm, defined by fixed circular collimators (5 centers) and by Iris(™) variable aperture collimator (4 centers). Setup conditions were: 80cm source to detector distance, and 1.5cm depth in water. To speed up measurements two diamond detectors were used and their equivalence was evaluated. MonteCarlo (MC) correction factors for silicon detectors were used for comparing the OF measurements. Considering OFs values averaged over all centers, diamond data resulted lower than uncorrected silicon diode ones. The agreement between diamond and MC corrected silicon values was within 0.6% for all fixed circular collimators. Relative differences between microDiamond and MC corrected silicon diodes data for Iris(™) collimator were lower than 1.0% for all apertures in the totality of centers. The two microDiamond detectors showed similar characteristics, in agreement with the technical specifications. Excellent agreement between microDiamond and MC corrected silicon diode detectors OFs was obtained for both collimation systems fixed cones and Iris(™), demonstrating the microDiamond could be a suitable detector for CyberKnife commissioning and routine checks. These results obtained in five centers suggest that for CyberKnife systems microDiamond can be used without corrections even at the smallest field size. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  5. Stereotactic radiosurgery for the treatment of mesial temporal lobe epilepsy.

    PubMed

    Feng, E-S; Sui, C-B; Wang, T-X; Sun, G-L

    2016-12-01

    Stereotactic radiosurgery (RS) is a potential option for some patients with temporal lobe epilepsy (TLE). The aim of this meta-analysis was to determine the pooled seizure-free rate and the time interval to seizure cessation in patients with lesions in the mesial temporal lobe, and who were eligible for either stereotactic or gamma knife RS. We searched the Medline, Cochrane, EMBASE, and Google Scholar databases using combinations of the following terms: RS, stereotactic radiosurgery, gamma knife, and TLE. We screened 103 articles and selected 13 for inclusion in the meta-analysis. Significant study heterogeneity was detected; however, the included studies displayed an acceptable level of quality. We show that approximately half of the patients were seizure free over a follow-up period that ranged from 6 months to 9 years [pooled estimate: 50.9% (95% confidence interval: 0.381-0.636)], with an average of 14 months to seizure cessation [pooled estimate: 14.08 months (95% confidence interval: 11.95-12.22 months)]. Nine of 13 included studies reported data for adverse events (AEs), which included visual field deficits and headache (the two most common AEs), verbal memory impairment, psychosis, psychogenic non-epileptic seizures, and dysphasia. Patients in the individual studies experienced AEs at rates that ranged from 8%, for non-epileptic seizures, to 85%, for headache. Our findings indicate that RS may have similar or slightly less efficacy in some patients compared with invasive surgery. Randomized controlled trials of both treatment regimens should be undertaken to generate an evidence base for patient decision-making. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Cutting a Drop of Water Pinned by Wire Loops Using a Superhydrophobic Surface and Knife

    PubMed Central

    Yanashima, Ryan; García, Antonio A.; Aldridge, James; Weiss, Noah; Hayes, Mark A.; Andrews, James H.

    2012-01-01

    A water drop on a superhydrophobic surface that is pinned by wire loops can be reproducibly cut without formation of satellite droplets. Drops placed on low-density polyethylene surfaces and Teflon-coated glass slides were cut with superhydrophobic knives of low-density polyethylene and treated copper or zinc sheets, respectively. Distortion of drop shape by the superhydrophobic knife enables a clean break. The driving force for droplet formation arises from the lower surface free energy for two separate drops, and it is modeled as a 2-D system. An estimate of the free energy change serves to guide when droplets will form based on the variation of drop volume, loop spacing and knife depth. Combining the cutting process with an electrofocusing driving force could enable a reproducible biomolecular separation without troubling satellite drop formation. PMID:23029297

  7. Force and work to shear green southern pine logs at slow speed

    Treesearch

    Peter Koch

    1971-01-01

    When logs of three diameter classes and two specific gravity classes were sheared with a 3/8-inch-thick knife travelling at 2 inches per minute, shearing force and work averaged greatest for dense 13.6-inch logs cut with a knife having a 45o sharpness angle (73,517 pounds; 49,838 foot-pounds). Force and work averaged at least 5.1-inch bolts of...

  8. Comparison of pain and swelling after removal of oral leukoplakia with CO2 laser and cold knife: A randomized clinical trial

    PubMed Central

    López-Jornet, Pía

    2013-01-01

    Objective: The aim of this study was to compare conventional surgery with carbon dioxide (CO2) laser in patients with oral leukoplakia, and to evaluate the postoperative pain and swelling. Study design: A total of 48 patients (27 males and 21 females) with a mean age of 53.7 ± 11.7 years and diagnosed with oral leukoplakia were randomly assigned to receive treatment either with conventional surgery using a cold knife or with a CO2 laser technique. A visual analog scale (VAS) was used to score pain and swelling at different postoperative time points. Results: Pain and swelling reported by the patients was greater with the conventional cold knife than with the CO2 laser, statistically significant differences for pain and swelling were observed between the two techniques during the first three days after surgery. Followed by a gradual decrease over one week. In neither group was granuloma formation observed, and none of the patients showed malignant transformation during the period of follow-up. Conclusions: The CO2 laser causes only minimal pain and swelling, thus suggesting that it may be an alternative method to conventional surgery in treating patients with oral leukoplakia. Key words:Oral leukoplakia, treatment, laser surgery, cold knife, pain, swelling. PMID:23229239

  9. Dependence of normal brain integral dose and normal tissue complication probability on the prescription isodose values for γ-knife radiosurgery

    NASA Astrophysics Data System (ADS)

    Ma, Lijun

    2001-11-01

    A recent multi-institutional clinical study suggested possible benefits of lowering the prescription isodose lines for stereotactic radiosurgery procedures. In this study, we investigate the dependence of the normal brain integral dose and the normal tissue complication probability (NTCP) on the prescription isodose values for γ-knife radiosurgery. An analytical dose model was developed for γ-knife treatment planning. The dose model was commissioned by fitting the measured dose profiles for each helmet size. The dose model was validated by comparing its results with the Leksell gamma plan (LGP, version 5.30) calculations. The normal brain integral dose and the NTCP were computed and analysed for an ensemble of treatment cases. The functional dependence of the normal brain integral dose and the NCTP versus the prescribing isodose values was studied for these cases. We found that the normal brain integral dose and the NTCP increase significantly when lowering the prescription isodose lines from 50% to 35% of the maximum tumour dose. Alternatively, the normal brain integral dose and the NTCP decrease significantly when raising the prescribing isodose lines from 50% to 65% of the maximum tumour dose. The results may be used as a guideline for designing future dose escalation studies for γ-knife applications.

  10. An optimized knife-edge method for on-orbit MTF estimation of optical sensors using powell parameter fitting

    NASA Astrophysics Data System (ADS)

    Han, Lu; Gao, Kun; Gong, Chen; Zhu, Zhenyu; Guo, Yue

    2017-08-01

    On-orbit Modulation Transfer Function (MTF) is an important indicator to evaluate the performance of the optical remote sensors in a satellite. There are many methods to estimate MTF, such as pinhole method, slit method and so on. Among them, knife-edge method is quite efficient, easy-to-use and recommended in ISO12233 standard for the wholefrequency MTF curve acquisition. However, the accuracy of the algorithm is affected by Edge Spread Function (ESF) fitting accuracy significantly, which limits the range of application. So in this paper, an optimized knife-edge method using Powell algorithm is proposed to improve the ESF fitting precision. Fermi function model is the most popular ESF fitting model, yet it is vulnerable to the initial values of the parameters. Considering the characteristics of simple and fast convergence, Powell algorithm is applied to fit the accurate parameters adaptively with the insensitivity to the initial parameters. Numerical simulation results reveal the accuracy and robustness of the optimized algorithm under different SNR, edge direction and leaning angles conditions. Experimental results using images of the camera in ZY-3 satellite show that this method is more accurate than the standard knife-edge method of ISO12233 in MTF estimation.

  11. Stereotactic radiosurgery in hemangioblastoma: Experience over 14 years

    PubMed Central

    Goyal, Nishant; Agrawal, Deepak; Singla, Raghav; Kale, Shashank Sharad; Singh, Manmohan; Sharma, Bhawani Shankar

    2016-01-01

    Background: Although gamma knife has been advocated for hemangioblastomas, it is not used widely by neurosurgeons. Objective: We review our experience over 14 years in an attempt to define the role of stereotactic radiosurgery (SRS) in the management of hemangioblastomas. Patients and Methods: A retrospective study was conducted on all patients of hemangioblastoma who underwent SRS at our institute over a period of 14 years (1998–2011). Gamma knife plans, clinical history, and radiology were reviewed for all patients. Results: A total of 2767 patients underwent gamma knife during the study period. Of these, 10 (0.36%) patients were treated for 24 hemangioblastomas. Eight patients (80%) had von Hippel-Lindau disease while two had sporadic hemangioblastomas. The median peripheral dose (50% isodose) delivered to the tumors was 29.9 Gy. Clinical and radiological follow-up data were available for eight patients. Of these, two were re-operated for persisting cerebellar symptoms. The remaining six patients were recurrence-free at a mean follow-up of 48 months (range 19–108 months). One patient had an increase in cyst volume along with a decrease in the size of the mural nodule. Conclusions: SRS should be the first option for asymptomatic hemangioblastomas. Despite the obvious advantages, gamma knife is not widely used as an option for hemangioblastomas. PMID:26933339

  12. Sealing Assembly for Sealing a Port and the Like

    NASA Technical Reports Server (NTRS)

    Haas, Jon W. (Inventor); Haupt, Charles W. (Inventor)

    2000-01-01

    The sealing assembly for a port of a valve or the like is disclosed. In detail, the sealing assembly includes the port having a circular shaped end with a circular shaped knife-edge thereon. The sealing assembly further includes a hollow cap having a closed first end with an aperture therethrough and an open second end. The cap further includes internal threads adapted to mate with the external threads of the port. A gasket is mounted within the cap having flat first and second principle sides and made of a deformable metal, the first principle side of the gasket for mounting against the circular shaped knife edge of the port. A plunger having a circular shaped disc portion is adapted to fit within the hollow cap and is engagable with the first principle surface of the gasket and includes a shaft portion extending out of the aperture. The cap and shaft of the plunger include external wrenching flats. Thus when the cap is screwed onto the port and the plunger is prevented from rotating by a wrench mounted on the wrenching flats of the shaft portion of the plunger, the gasket is forced into engagement with the knife edge in pure compression and no rotation of the gasket occurs causing the knife edge to locally deform the gasket sealing of the port.

  13. Shot sequencing based on biological equivalent dose considerations for multiple isocenter Gamma Knife radiosurgery

    NASA Astrophysics Data System (ADS)

    Ma, Lijun; Lee, Letitia; Barani, Igor; Hwang, Andrew; Fogh, Shannon; Nakamura, Jean; McDermott, Michael; Sneed, Penny; Larson, David A.; Sahgal, Arjun

    2011-11-01

    Rapid delivery of multiple shots or isocenters is one of the hallmarks of Gamma Knife radiosurgery. In this study, we investigated whether the temporal order of shots delivered with Gamma Knife Perfexion would significantly influence the biological equivalent dose for complex multi-isocenter treatments. Twenty single-target cases were selected for analysis. For each case, 3D dose matrices of individual shots were extracted and single-fraction equivalent uniform dose (sEUD) values were determined for all possible shot delivery sequences, corresponding to different patterns of temporal dose delivery within the target. We found significant variations in the sEUD values among these sequences exceeding 15% for certain cases. However, the sequences for the actual treatment delivery were found to agree (<3%) and to correlate (R2 = 0.98) excellently with the sequences yielding the maximum sEUD values for all studied cases. This result is applicable for both fast and slow growing tumors with α/β values of 2 to 20 according to the linear-quadratic model. In conclusion, despite large potential variations in different shot sequences for multi-isocenter Gamma Knife treatments, current clinical delivery sequences exhibited consistent biological target dosing that approached that maximally achievable for all studied cases.

  14. TiO2 gas sensor to detect the propanol at room temperature

    NASA Astrophysics Data System (ADS)

    Gaidan, Ibrahim; Asbia, Salim; Brabazon, Dermot; Ahad, Inam Ul

    2017-10-01

    Titanium dioxide (TiO2) was used as raw material to create sensing materials for gas sensor applications. The sample was mixed with isopropanol and wet-ball milled for 24 hours and then dried at 120°C to evaporate the solvent. Twenty grams of the dried powder was then pressed at 2 tons (27.58 MPa) using a pellet die. The pellet was heated at 1250°C in air for 5 hours and then milled for 10 minutes to powder form using a Gy-RO Mill machine. FIB and SEM analysis were used to study the microstructure of the materials. The polyvinyl butyral (5 wt.%) was used as a binder, while ethylenglycolmonobutylether served as a solvent to make a suitable paste. The paste was screen-printed on top of an alumina substrate that had copper electrodes to form the sensor. The sensor was used to detect propanol at room temperature over two different ranges (500 to 3000 ppm and 2500 to 5000 ppm). It was observed that the response of the device increased proportionally with increasing gas concentration repeatability.

  15. 7 CFR 868.312 - Grade and grade requirements for the class Screenings Milled Rice. (See also § 868.315.)

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Requirements, and Grade Designations Grade Maximum limits of— Paddy kernels and seeds Total(number in 500 grams) Objectionable seeds (number in 500 grams) Chalky kernels 1,3 (percent) Color requirements 1 Minimum... objectionable foreign odor; (e) has a badly damaged or extremely red appearance (f) contains more than 0.1...

  16. 7 CFR 868.312 - Grade and grade requirements for the class Screenings Milled Rice. (See also § 868.315.)

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Requirements, and Grade Designations Grade Maximum limits of— Paddy kernels and seeds Total(number in 500 grams) Objectionable seeds (number in 500 grams) Chalky kernels 1 3 (percent) Color requirements 1 Minimum... objectionable foreign odor; (e) has a badly damaged or extremely red appearance (f) contains more than 0.1...

  17. Relative risk analysis of the use of radiation-emitting medical devices: A preliminary application

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, E.D.

    This report describes the development of a risk analysis approach for evaluating the use of radiation-emitting medial devices. This effort was performed by Lawrence Livermore National Laboratory for the US Nuclear Regulatory Commission (NRC). The assessment approach has bee applied to understand the risks in using the Gamma Knife, a gamma irradiation therapy device. This effort represents an initial step to evaluate the potential role of risk analysis for developing regulations and quality assurance requirements in the use of nuclear medical devices. The risk approach identifies and assesses the most likely risk contributors and their relative importance for the medicalmore » system. The approach uses expert screening techniques and relative risk profiling to incorporate the type, quality, and quantity of data available and to present results in an easily understood form.« less

  18. Development of size reduction equations for calculating power input for grinding pine wood chips using hammer mill

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Naimi, Ladan J.; Collard, Flavien; Bi, Xiaotao

    Size reduction is an unavoidable operation for preparing biomass for biofuels and bioproduct conversion. Yet, there is considerable uncertainty in power input requirement and the uniformity of ground biomass. Considerable gains are possible if the required power input for a size reduction ratio is estimated accurately. In this research three well-known mechanistic equations attributed to Rittinger, Kick, and Bond available for predicting energy input for grinding pine wood chips were tested against experimental grinding data. Prior to testing, samples of pine wood chips were conditioned to 11.7% wb, moisture content. The wood chips were successively ground in a hammer millmore » using screen sizes of 25.4 mm, 10 mm, 6.4 mm, and 3.2 mm. The input power and the flow of material into the grinder were recorded continuously. The recorded power input vs. mean particle size showed that the Rittinger equation had the best fit to the experimental data. The ground particle sizes were 4 to 7 times smaller than the size of installed screen. Geometric mean size of particles were calculated using two methods (1) Tyler sieves and using particle size analysis and (2) Sauter mean diameter calculated from the ratio of volume to surface that were estimated from measured length and width. The two mean diameters agreed well, pointing to the fact that either mechanical sieving or particle imaging can be used to characterize particle size. In conclusion, specific energy input to the hammer mill increased from 1.4 kWh t –1 (5.2 J g –1) for large 25.1-mm screen to 25 kWh t –1 (90.4 J g –1) for small 3.2-mm screen.« less

  19. High drug loading self-microemulsifying/micelle formulation: design by high-throughput formulation screening system and in vivo evaluation.

    PubMed

    Sakai, Kenichi; Obata, Kouki; Yoshikawa, Mayumi; Takano, Ryusuke; Shibata, Masaki; Maeda, Hiroyuki; Mizutani, Akihiko; Terada, Katsuhide

    2012-10-01

    To design a high drug loading formulation of self-microemulsifying/micelle system. A poorly-soluble model drug (CH5137291), 8 hydrophilic surfactants (HS), 10 lipophilic surfactants (LS), 5 oils, and PEG400 were used. A high loading formulation was designed by a following stepwise approach using a high-throughput formulation screening (HTFS) system: (1) an oil/solvent was selected by solubility of the drug; (2) a suitable HS for highly loading was selected by the screenings of emulsion/micelle size and phase stability in binary systems (HS, oil/solvent) with increasing loading levels; (3) a LS that formed a broad SMEDDS/micelle area on a phase diagram containing the HS and oil/solvent was selected by the same screenings; (4) an optimized formulation was selected by evaluating the loading capacity of the crystalline drug. Aqueous solubility behavior and oral absorption (Beagle dog) of the optimized formulation were compared with conventional formulations (jet-milled, PEG400). As an optimized formulation, d-α-tocopheryl polyoxyethylene 1000 succinic ester: PEG400 = 8:2 was selected, and achieved the target loading level (200 mg/mL). The formulation formed fine emulsion/micelle (49.1 nm), and generated and maintained a supersaturated state at a higher level compared with the conventional formulations. In the oral absorption test, the area under the plasma concentration-time curve of the optimized formulation was 16.5-fold higher than that of the jet-milled formulation. The high loading formulation designed by the stepwise approach using the HTFS system improved the oral absorption of the poorly-soluble model drug.

  20. Development of size reduction equations for calculating power input for grinding pine wood chips using hammer mill

    DOE PAGES

    Naimi, Ladan J.; Collard, Flavien; Bi, Xiaotao; ...

    2016-01-05

    Size reduction is an unavoidable operation for preparing biomass for biofuels and bioproduct conversion. Yet, there is considerable uncertainty in power input requirement and the uniformity of ground biomass. Considerable gains are possible if the required power input for a size reduction ratio is estimated accurately. In this research three well-known mechanistic equations attributed to Rittinger, Kick, and Bond available for predicting energy input for grinding pine wood chips were tested against experimental grinding data. Prior to testing, samples of pine wood chips were conditioned to 11.7% wb, moisture content. The wood chips were successively ground in a hammer millmore » using screen sizes of 25.4 mm, 10 mm, 6.4 mm, and 3.2 mm. The input power and the flow of material into the grinder were recorded continuously. The recorded power input vs. mean particle size showed that the Rittinger equation had the best fit to the experimental data. The ground particle sizes were 4 to 7 times smaller than the size of installed screen. Geometric mean size of particles were calculated using two methods (1) Tyler sieves and using particle size analysis and (2) Sauter mean diameter calculated from the ratio of volume to surface that were estimated from measured length and width. The two mean diameters agreed well, pointing to the fact that either mechanical sieving or particle imaging can be used to characterize particle size. In conclusion, specific energy input to the hammer mill increased from 1.4 kWh t –1 (5.2 J g –1) for large 25.1-mm screen to 25 kWh t –1 (90.4 J g –1) for small 3.2-mm screen.« less

  1. Analyzer for measuring gas contained in the pore space of rocks

    NASA Astrophysics Data System (ADS)

    Kudasik, Mateusz; Skoczylas, Norbert

    2017-10-01

    In the present paper, the authors discussed the functioning of their own analyzer for measuring gas contained in the pore space of high strength rocks. A sample is placed inside a hermetic measuring chamber, and then undergoes impact milling as a result of colliding with the vibrating blade of a knife which is rotationally driven by a high-speed brushless electric motor. The measuring chamber is equipped with all the necessary sensors, i.e. gas, pressure, and temperature sensors. Trial tests involving the comminution of dolomite and anhydrite samples demonstrated that the constructed device is able to break up rocks into grains so fine that they are measured in single microns, and the sensors used in the construction ensure balancing of the released gas. The tests of the analyzer showed that the metrological concept behind it, together with the way it was built, make it fit for measurements of the content and composition of selected gases from the rock pore space. On the basis of the conducted tests of balancing the gases contained in the two samples, it was stated that the gas content of Sample no. 1 was (0.055  ±  0.002) cm3 g-1, and Sample no. 2 contained gas at atmospheric pressure, composed mostly of air.

  2. Hydrogen storage materials discovery via high throughput ball milling and gas sorption.

    PubMed

    Li, Bin; Kaye, Steven S; Riley, Conor; Greenberg, Doron; Galang, Daniel; Bailey, Mark S

    2012-06-11

    The lack of a high capacity hydrogen storage material is a major barrier to the implementation of the hydrogen economy. To accelerate discovery of such materials, we have developed a high-throughput workflow for screening of hydrogen storage materials in which candidate materials are synthesized and characterized via highly parallel ball mills and volumetric gas sorption instruments, respectively. The workflow was used to identify mixed imides with significantly enhanced absorption rates relative to Li2Mg(NH)2. The most promising material, 2LiNH2:MgH2 + 5 atom % LiBH4 + 0.5 atom % La, exhibits the best balance of absorption rate, capacity, and cycle-life, absorbing >4 wt % H2 in 1 h at 120 °C after 11 absorption-desorption cycles.

  3. Development of seal ring carbon-graphite materials (tasks 8, 9, and 10)

    NASA Technical Reports Server (NTRS)

    Fechter, N. J.; Petrunich, P. S.

    1973-01-01

    A screening study was conducted to develop improved carbon-graphite materials for use in self-acting seals at air temperatures to 1300 F (704 C). Property measurements on materials prepared during this study have shown that: (1) The mechanical properties of a carbon-graphite material were significantly improved by using a fine milled artificial graphite filler material and including intensive mixing, warm molding, and pitch impregnation in the processing; and (2) the oxidation resistance of a carbon-graphite material was improved by including fine milled boron carbide as an oxidation-inhibiting additive. These techniques were employed to develop a material that has 10 times more oxidation resistance than that of a widely used commercial grade and mechanical properties that approach those of the commercial grade.

  4. Differential phase microscope and micro-tomography with a Foucault knife-edge scanning filter

    NASA Astrophysics Data System (ADS)

    Watanabe, N.; Hashizume, J.; Goto, M.; Yamaguchi, M.; Tsujimura, T.; Aoki, S.

    2013-10-01

    An x-ray differential phase microscope with a Foucault knife-edge scanning filter was set up at the bending magnet source BL3C, Photon Factory. A reconstructed phase profile from the differential phase image of an aluminium wire at 5.36 keV was fairly good agreement with the numerical simulation. Phase tomography of a biological specimen, such as an Artemia cyst, could be successfully demonstrated.

  5. Examining the Reasons Black Male Youths Give for Committing Crime with Reference to Inner City Areas of London

    ERIC Educational Resources Information Center

    Achinewhu-Nworgu, Elizabeth; Nworgu, Chioma; Azaiki, Steve; Nworgu, Helen

    2013-01-01

    This paper presents a mini research carried out by the Focus Learning Support (FLS) team on reasons why young black males in the community commit crime. Knife and gun crime is seen as a serious problem in the black community involving black males in the inner London city areas--many of whom are both victims and offenders of knife and gun crime.…

  6. Successful use of Gamma Knife surgery in a distal lenticulostriate artery aneurysm intervention.

    PubMed

    Lan, ZhiGang; Li, Jin; You, Chao; Chen, Jing

    2012-02-01

    We report a case of a 21-year-old woman who underwent radiosurgical treatment of a distal lenticulostriate artery (LSA) aneurysm. Twenty-two months after treatment, repeat angiography demonstrated patency of the parent vessel and complete obliteration of the aneurysm. Our case implies that Gamma Knife surgery (GKS) might serve as an alternative microinvasive technique in the treatment of LSA aneurysms, making this procedure a potential addition to present methods.

  7. Industrial Computer Codes

    NASA Technical Reports Server (NTRS)

    Shapiro, Wilbur

    1996-01-01

    This is an overview of new and updated industrial codes for seal design and testing. GCYLT (gas cylindrical seals -- turbulent), SPIRALI (spiral-groove seals -- incompressible), KTK (knife to knife) Labyrinth Seal Code, and DYSEAL (dynamic seal analysis) are covered. CGYLT uses G-factors for Poiseuille and Couette turbulence coefficients. SPIRALI is updated to include turbulence and inertia, but maintains the narrow groove theory. KTK labyrinth seal code handles straight or stepped seals. And DYSEAL provides dynamics for the seal geometry.

  8. SRAO: optical design and the dual-knife-edge WFS

    NASA Astrophysics Data System (ADS)

    Ziegler, Carl; Law, Nicholas M.; Tokovinin, Andrei

    2016-07-01

    The Southern Robotic Adaptive Optics (SRAO) instrument will bring the proven high-efficiency capabilities of Robo-AO to the Southern-Hemisphere, providing the unique capability to image with high-angular-resolution thousands of targets per year across the entire sky. Deployed on the modern 4.1m SOAR telescope located on Cerro Tololo, the NGS AO system will use an innovative dual-knife-edge wavefront sensor, similar to a pyramid sensor, to enable guiding on targets down to V=16 with diffraction limited resolution in the NIR. The dual-knife-edge wavefront sensor can be up to two orders of magnitude less costly than custom glass pyramids, with similar wavefront error sensitivity and minimal chromatic aberrations. SRAO is capable of observing hundreds of targets a night through automation, allowing confirmation and characterization of the large number of exoplanets produced by current and future missions.

  9. CyberArc: a non-coplanar-arc optimization algorithm for CyberKnife

    NASA Astrophysics Data System (ADS)

    Kearney, Vasant; Cheung, Joey P.; McGuinness, Christopher; Solberg, Timothy D.

    2017-07-01

    The goal of this study is to demonstrate the feasibility of a novel non-coplanar-arc optimization algorithm (CyberArc). This method aims to reduce the delivery time of conventional CyberKnife treatments by allowing for continuous beam delivery. CyberArc uses a 4 step optimization strategy, in which nodes, beams, and collimator sizes are determined, source trajectories are calculated, intermediate radiation models are generated, and final monitor units are calculated, for the continuous radiation source model. The dosimetric results as well as the time reduction factors for CyberArc are presented for 7 prostate and 2 brain cases. The dosimetric quality of the CyberArc plans are evaluated using conformity index, heterogeneity index, local confined normalized-mutual-information, and various clinically relevant dosimetric parameters. The results indicate that the CyberArc algorithm dramatically reduces the treatment time of CyberKnife plans while simultaneously preserving the dosimetric quality of the original plans.

  10. CyberArc: a non-coplanar-arc optimization algorithm for CyberKnife.

    PubMed

    Kearney, Vasant; Cheung, Joey P; McGuinness, Christopher; Solberg, Timothy D

    2017-06-26

    The goal of this study is to demonstrate the feasibility of a novel non-coplanar-arc optimization algorithm (CyberArc). This method aims to reduce the delivery time of conventional CyberKnife treatments by allowing for continuous beam delivery. CyberArc uses a 4 step optimization strategy, in which nodes, beams, and collimator sizes are determined, source trajectories are calculated, intermediate radiation models are generated, and final monitor units are calculated, for the continuous radiation source model. The dosimetric results as well as the time reduction factors for CyberArc are presented for 7 prostate and 2 brain cases. The dosimetric quality of the CyberArc plans are evaluated using conformity index, heterogeneity index, local confined normalized-mutual-information, and various clinically relevant dosimetric parameters. The results indicate that the CyberArc algorithm dramatically reduces the treatment time of CyberKnife plans while simultaneously preserving the dosimetric quality of the original plans.

  11. Endoscopic submucosal dissection using flexknife.

    PubMed

    Kodashima, Shinya; Fujishiro, Mitsuhiro; Yahagi, Naohisa; Kakushima, Naomi; Omata, Masao

    2006-01-01

    Although the standard treatment for early-stage gastrointestinal tumors is still surgical resection, endoscopic resection has been accepted for some of these lesions, especially in Japan. However, the indication was limited until recently to achieve en bloc resection and prevent local recurrence. To overcome the disadvantage of endoscopic resection with conventional endoscopic mucosal resection (EMR), several investigators, including us, have developed a new endoscopic resection technique: endoscopic submucosal dissection (ESD). ESD is a remarkable technique that enables to remove the lesions en bloc regardless of size, shape, coexisting ulcer, and location. Nowadays, several knives are available for ESD, such as the needle knife, insulation-tipped (IT) knife, Hookknife, triangle-tipped (TT) knife, and Flexknife. Each of them has some merits and demerits, and the ways to use the knives are different. We summarize here how to use the Flexknife, which we made ourselves in cooperation with the Olympus Company, and how we use the technique in our hospital.

  12. 40 CFR 421.33 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... .000 .000 Aluminum .000 .000 Ammonia (as N) .000 .000 (b) Subpart C—Scrap Screening and Milling. BAT... Aluminum .000 .000 Ammonia (as N) .000 .000 (c) Subpart C—Dross Washing. BAT Effluent Limitations Pollutant... pounds) of dross washed Lead 3.043 1.413 Zinc 11.090 4.565 Aluminum 66.410 29.450 Ammonia (as N) 1,449...

  13. 40 CFR 421.33 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... .000 .000 Aluminum .000 .000 Ammonia (as N) .000 .000 (b) Subpart C—Scrap Screening and Milling. BAT... Aluminum .000 .000 Ammonia (as N) .000 .000 (c) Subpart C—Dross Washing. BAT Effluent Limitations Pollutant... pounds) of dross washed Lead 3.043 1.413 Zinc 11.090 4.565 Aluminum 66.410 29.450 Ammonia (as N) 1,449...

  14. 40 CFR 421.33 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... .000 .000 Aluminum .000 .000 Ammonia (as N) .000 .000 (b) Subpart C—Scrap Screening and Milling. BAT... Aluminum .000 .000 Ammonia (as N) .000 .000 (c) Subpart C—Dross Washing. BAT Effluent Limitations Pollutant... pounds) of dross washed Lead 3.043 1.413 Zinc 11.090 4.565 Aluminum 66.410 29.450 Ammonia (as N) 1,449...

  15. Forward treatment planning techniques to reduce the normalization effect in Gamma Knife radiosurgery.

    PubMed

    Cheng, Hao-Wen; Lo, Wei-Lun; Kuo, Chun-Yuan; Su, Yu-Kai; Tsai, Jo-Ting; Lin, Jia-Wei; Wang, Yu-Jen; Pan, David Hung-Chi

    2017-11-01

    In Gamma Knife forward treatment planning, normalization effect may be observed when multiple shots are used for treating large lesions. This effect can reduce the proportion of coverage of high-value isodose lines within targets. The aim of this study was to evaluate the performance of forward treatment planning techniques using the Leksell Gamma Knife for the normalization effect reduction. We adjusted the shot positions and weightings to optimize the dose distribution and reduce the overlap of high-value isodose lines from each shot, thereby mitigating the normalization effect during treatment planning. The new collimation system, Leksell Gamma Knife Perfexion, which contains eight movable sectors, provides an additional means to reduce the normalization effect by using composite shots. We propose different techniques in forward treatment planning that can reduce the normalization effect. Reducing the normalization effect increases the coverage proportion of higher isodose lines within targets, making the high-dose region within targets more uniform and increasing the mean dose to targets. Because of the increase in the mean dose to the target after reducing the normalization effect, we can set the prescribed marginal dose at a higher isodose level and reduce the maximum dose, thereby lowering the risk of complications. © 2017 Shuang Ho Hospital-Taipei Medical University. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  16. Brain metastases in cancer patients attending a Gamma Knife Center: A study from a single institute in Iran

    PubMed Central

    Azimi, Parisa; Shahzadi, Sohrab; Bitaraf, Mohammad Ali; Azar, Maziar; Alikhani, Mazdak; Zali, Alireza; Sadeghi, Sohrab; Montazeri, Ali

    2017-01-01

    Background: This study was aimed to explore data on brain metastases in cancer patients attending the Iranian Gamma Knife Center. Meterials and Methods: This was a retrospective study. In all 5216 case records of patients who referred to the Iranian Gamma Knife Center for treatment of brain tumors during year 2003-2011 were reviewed. Data were explored to identify patients who developed brain metastases due to cancer and assessed the information as applied to cancer patients including survival analysis. Results: Two hundred and twenty patients were identified as having brain metastases due to cancer. The mean age of patients was 54.0 (standard deviation [SD] =12.7) years. Patients were followed for an average of 7 months after treatment with gamma-knife. The median survival time for different the Graded Prognostic Assessment (GPA) was: GPA: 0-1, 4.0 ± 0.4 months; GPA: 1.5-2.5, 6.0 ± 0.7 months; GPA: 3, 9.0 ± 0.9 months; and GPA: 3.5-4.0, 12.0 ± 1.8 months and the overall median survival was 7.0 (SD = 0.6) months. Conclusion: The findings suggest that many cancer patients in Iran might develop brain metastasis. Although, this is not a very high incidence compared with the existing statistics from other countries, there is an urgent need to explore the issue further. PMID:28761536

  17. Ribbons of semithin sections: an advanced method with a new type of diamond knife.

    PubMed

    Blumer, Michael J F; Gahleitner, P; Narzt, T; Handl, C; Ruthensteiner, B

    2002-10-15

    Complete series of semithin sections are imperative for 3-D reconstruction, but with traditional microtomy techniques it is difficult and time-consuming to trace stained and labeled structures. In the present study we introduce a method for making and collecting ribbons of semithin sections with a new, commercial available diamond knife (histo-jumbo-diamond knife, Diatome AG, Biel, Switzerland). The special feature of the diamond knife is the large water bath (boat) into which a glass slide can be dipped. The method has distinct advantages and the handling is simple. The resin block is trimmed into a truncated pyramid. Contact glue is applied to the leading face of the pyramid, which makes sections stick together to form a ribbon. Following sectioning, the ribbons are mounted onto glass slides and aligned in parallel. Stretching out and drying the ribbons on a hot plate is the final step of the method. Major advantages of this method are the perfect alignment of sections with identical orientation of structures, the completeness of series, and the significant saving of time. This facilitates tracing of stained and labeled structures, yielding quick 3-D reconstruction. Semithin sections can be cut from 0.5 to 2 micro m and several ribbons can be mounted side by side onto the slide. Two examples are presented to illustrate the advantages of the method.

  18. Craniosynostosis incision: scalpel or cautery?

    PubMed

    Wood, Jeyhan S; Kittinger, Benjamin J; Perry, Victor L; Adenola, Adeyemi; van Aalst, John A

    2014-07-01

    There is an ongoing debate regarding the optimal instrument for scalp incisions: the scalpel or electrocautery. The argument generally focuses on improved healing after an incision made with a knife and decreased bleeding when using electrocautery. This study compares the use of scalpel and electrocautery in making coronal incisions for patients undergoing surgical correction of craniosynostosis. The outcome metric used is wound healing within 6 months after surgery. All patients presenting to the University of North Carolina Children's Hospital with craniosynostosis between July 1, 2007 and January 1, 2010 requiring a coronal incision for surgical correction were prospectively enrolled. In all of these patients, half of the coronal incision was made with knife; the other half, with needle tip cautery. Side of the incision was specified at the time of surgery in the operative report. Patients were excluded from the study if the instrument for incision was not specified or if only 1 modality was used for the entire incision. Sixty-eight patients underwent cranial vault reconstruction, of which 58 met inclusion criteria. Of the 58 matched pairs, 55 were analyzed statistically. The 3 excluded cases were those who had midline complications. There were 17 wound complications (15%): 8 in the knife group, 6 in the cautery group, and 3 at midline (with indeterminate side for the problem). We found no statistically significant difference in wound healing between incisions made with a knife or with electrocautery.

  19. Brain metastases in cancer patients attending a Gamma Knife Center: A study from a single institute in Iran.

    PubMed

    Azimi, Parisa; Shahzadi, Sohrab; Bitaraf, Mohammad Ali; Azar, Maziar; Alikhani, Mazdak; Zali, Alireza; Sadeghi, Sohrab; Montazeri, Ali

    2017-01-01

    This study was aimed to explore data on brain metastases in cancer patients attending the Iranian Gamma Knife Center. This was a retrospective study. In all 5216 case records of patients who referred to the Iranian Gamma Knife Center for treatment of brain tumors during year 2003-2011 were reviewed. Data were explored to identify patients who developed brain metastases due to cancer and assessed the information as applied to cancer patients including survival analysis. Two hundred and twenty patients were identified as having brain metastases due to cancer. The mean age of patients was 54.0 (standard deviation [SD] =12.7) years. Patients were followed for an average of 7 months after treatment with gamma-knife. The median survival time for different the Graded Prognostic Assessment (GPA) was: GPA: 0-1, 4.0 ± 0.4 months; GPA: 1.5-2.5, 6.0 ± 0.7 months; GPA: 3, 9.0 ± 0.9 months; and GPA: 3.5-4.0, 12.0 ± 1.8 months and the overall median survival was 7.0 (SD = 0.6) months. The findings suggest that many cancer patients in Iran might develop brain metastasis. Although, this is not a very high incidence compared with the existing statistics from other countries, there is an urgent need to explore the issue further.

  20. Worldwide variance in the potential utilization of Gamma Knife radiosurgery.

    PubMed

    Hamilton, Travis; Dade Lunsford, L

    2016-12-01

    OBJECTIVE The role of Gamma Knife radiosurgery (GKRS) has expanded worldwide during the past 3 decades. The authors sought to evaluate whether experienced users vary in their estimate of its potential use. METHODS Sixty-six current Gamma Knife users from 24 countries responded to an electronic survey. They estimated the potential role of GKRS for benign and malignant tumors, vascular malformations, and functional disorders. These estimates were compared with published disease epidemiological statistics and the 2014 use reports provided by the Leksell Gamma Knife Society (16,750 cases). RESULTS Respondents reported no significant variation in the estimated use in many conditions for which GKRS is performed: meningiomas, vestibular schwannomas, and arteriovenous malformations. Significant variance in the estimated use of GKRS was noted for pituitary tumors, craniopharyngiomas, and cavernous malformations. For many current indications, the authors found significant variance in GKRS users based in the Americas, Europe, and Asia. Experts estimated that GKRS was used in only 8.5% of the 196,000 eligible cases in 2014. CONCLUSIONS Although there was a general worldwide consensus regarding many major indications for GKRS, significant variability was noted for several more controversial roles. This expert opinion survey also suggested that GKRS is significantly underutilized for many current diagnoses, especially in the Americas. Future studies should be conducted to investigate health care barriers to GKRS for many patients.

  1. Emergency endoscopic needle-knife precut papillotomy in acute severe cholangitis resulting from impacted common bile duct stones at duodenal papilla.

    PubMed

    Zheng, Mingwei; Liu, Xufeng; Li, Ning; Li, Wei-Zhi

    2018-03-01

    To evaluate the efficacy and safety of emergency endoscopic needle-knife precut papillotomy in acute severe cholangitis resulting from impacted common bile duct stones at duodenal papilla. Between January 2010 and January 2015, 118 cases of acute severe cholangitis with impacted common bile duct stones at the native papilla underwent emergency endoscopic retrograde cholangiopancreatography (ERCP) and early needle-knife precut papillotomy in a tertiary referral center. Precut techniques were performed according to the different locations of stones in the duodenal papilla. Clinical data about therapy and recovery of the 118 patients were recorded and analyzed. One hundred and eighteen patients underwent emergency ERCP within 24 h after hospitalization, with a total success rate of 100%. The mean operating time was 6.4 ± 4.1 min. Postoperative acute physiology and chronic health evaluation (APACHE) II scores, white blood cell count and liver function improved significantly. The complication rate was 4.2% (5/118); two with hemorrhage and three with acute pancreatitis. There was no procedure-related mortality. Emergency endoscopic needle-knife precut papillotomy is effective and safe for acute severe cholangitis resulting from impacted common bile duct stones at the duodenal papilla. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  2. Ten-Year Survival of a Patient Treated with Stereotactic Gamma Knife Radiosurgery for Brain Metastases from Colon Cancer with Ovarian and Lymph Node Metastases: A Case Report.

    PubMed

    Morinaga, Nobuhiro; Tanaka, Naritaka; Shitara, Yoshinori; Ishizaki, Masatoshi; Yoshida, Takatomo; Kouga, Hideaki; Wakabayashi, Kazuki; Fukuchi, Minoru; Tsunoda, Yoshiyuki; Kuwano, Hiroyuki

    2016-01-01

    Brain metastasis from colorectal cancer is infrequent and carries a poor prognosis. Herein, we present a patient alive 10 years after the identification of a first brain metastasis from sigmoid colon cancer. A 39-year-old woman underwent sigmoidectomy for sigmoid colon cancer during an emergency operation for pelvic peritonitis. The pathological finding was moderately differentiated adenocarcinoma. Eleven months after the sigmoidectomy, a metastatic lesion was identified in the left ovary. Despite local radiotherapy followed by chemotherapy, the left ovarian lesion grew, so resection of the uterus and bilateral ovaries was performed. Adjuvant chemotherapy with tegafur-uracil (UFT)/calcium folinate (leucovorin, LV) was initiated. Seven months after resection of the ovarian lesion, brain metastases appeared in the bilateral frontal lobes and were treated with stereotactic Gamma Knife radiosurgery. Cervical and mediastinal lymph node metastases were also diagnosed, and irradiation of these lesions was performed. After radiotherapy, 10 courses of oxaliplatin and infused fluorouracil plus leucovorin (FOLFOX) were administered. During FOLFOX administration, recurrent left frontal lobe brain metastasis was diagnosed and treated with stereotactic Gamma Knife radiosurgery. In this case, the brain metastases were well treated with stereotactic Gamma Knife radiosurgery, and the systemic disease arising from sigmoid colon cancer has been kept under control with chemotherapies, surgical resection, and radiotherapy.

  3. Does the stoichiometric carbon:phosphorus knife edge apply for predaceous copepods?

    PubMed

    Laspoumaderes, Cecilia; Modenutti, Beatriz; Elser, James J; Balseiro, Esteban

    2015-06-01

    Recent work has indicated that stoichiometric food quality in terms of the carbon:phosphorus (C:P) ratio affects consumers whether the imbalance involves a deficit or an excess of nutrients; hence, organisms exist on a "stoichiometric knife edge". While previous studies have focused primarily on autotroph-herbivore trophic transfer, nutritional imbalances may also affect the interactions between species at higher trophic levels. Since the foods of carnivores are normally stoichiometrically similar to the body compositions of those carnivores, they may be more severely affected than herbivores if imbalances become pronounced. We analysed the response of the predatory copepod Parabroteas sarsi to monospecific diet treatments consisting of high and low C:P prey items. These dietary treatments strongly affected the predator's elemental composition and growth, although prey selection, excretion, egestion, and respiration rates were not affected. We suggest that, due to their low threshold elemental ratio and a narrow C:P stoichiometric knife edge, these predators are highly vulnerable to stoichiometric imbalances, whether an excess or a deficit of nutrients is involved. Our results demonstrating this high sensitivity to prey C:P ratio show that the stoichiometric knife edge may apply to not only herbivores but also higher trophic levels. Thus, predators such as P. sarsi, with a much narrower range of food quality, may also be strongly affected by fluctuations in the quality of their prey, with negative consequences for their secondary production.

  4. Suspended-sediment loads from major tributaries to the Missouri River between Garrison Dam and Lake Oahe, North Dakota, 1954-98

    USGS Publications Warehouse

    Macek-Rowland, Kathleen M.

    2000-01-01

    Annual suspended-sediment loads for water years 1954 through 1998 were estimated for the major tributaries in the Missouri River Basin between Garrison Dam and Lake Oahe in North Dakota and for the Missouri River at Garrison Dam and the Missouri River at Bismarck, N. Dak.  The major tributaries are the Knife River, Turtle Creek, Painted Woods Creek, Square Butte Creek, Burnt Creek, Heart River, and Apple Creek.  Sediment and streamflow data used to estimate the suspended-sediment loads were from selected U.S. Geological Survey streamflow-gaging stations located within each basin.  Some of the stations had no sediment data available and limited continuous streamflow data for water years 1954 through 1998.  Therefore, data from nearby streamflow-gaging stations were assumed for the calculations. The Heart River contributed the largest amount of suspended sediment to the Missouri River for 1954-98.  Annual suspended-sediment loads in the Heart River near Mandan ranged from less than 1 to 40 percent of the annual suspended-sediment load in the Missouri River. The Knife River contributed the second largest amount of suspended sediment to the Missouri River.  Annual suspended-sediment loads in the Knife River at Hazen ranged from less than 1 to 19 percent of the annual suspended-sediment load in the Missouri River.  Apple Creek, Turtle Creek, Painted Woods Creek, Square Butte Creek, and Burnt Creek all contributed 2 percent or less of the annual suspended-sediment load in the Missouri River.  The Knife River and the Heart River also had the largest average suspended-sediment yields for the seven tributaries.  The yield for the Knife River was 91.1 tons per square mile, and the yield for the Heart River was 133 tons per square mile.  The remaining five tributaries had yields of less than 24 tons per square mile based on total drainage area. 

  5. Adaptive fractionated stereotactic Gamma Knife radiotherapy of meningioma using integrated stereotactic cone-beam-CT and adaptive re-planning (a-gkFSRT).

    PubMed

    Stieler, F; Wenz, F; Abo-Madyan, Y; Schweizer, B; Polednik, M; Herskind, C; Giordano, F A; Mai, S

    2016-11-01

    The Gamma Knife Icon (Elekta AB, Stockholm, Sweden) allows frameless stereotactic treatment using a combination of cone beam computer tomography (CBCT), a thermoplastic mask system, and an infrared-based high-definition motion management (HDMM) camera system for patient tracking during treatment. We report on the first patient with meningioma at the left petrous bone treated with adaptive fractionated stereotactic radiotherapy (a-gkFSRT). The first patient treated with Gamma Knife Icon at our institute received MR imaging for preplanning before treatment. For each treatment fraction, a daily CBCT was performed to verify the actual scull/tumor position. The system automatically adapted the planned shot positions to the daily position and recalculated the dose distribution (online adaptive planning). During treatment, the HDMM system recorded the intrafractional patient motion. Furthermore, the required times were recorded to define a clinical treatment slot. Total treatment time was around 20 min. Patient positioning needed 0.8 min, CBCT positioning plus acquisition 1.65 min, CT data processing and adaptive planning 2.66 min, and treatment 15.6 min. The differences for the five daily CBCTs compared to the reference are for rotation: -0.59 ± 0.49°/0.18 ± 0.20°/0.05 ± 0.36° and for translation: 0.94 ± 0.52 mm/-0.08 ± 0.08 mm/-1.13 ± 0.89 mm. Over all fractions, an intrafractional movement of 0.13 ± 0.04 mm was observed. The Gamma Knife Icon allows combining the accuracy of the stereotactic Gamma Knife system with the flexibility of fractionated treatment with the mask system and CBCT. Furthermore, the Icon system introduces a new online patient tracking system to the clinical routine. The interfractional accuracy of patient positioning was controlled with a thermoplastic mask and CBCT.

  6. SU-E-T-281: Reduction of Treatment Times in CyberKnife Prostate SBRT Using a Water Filled Rectal Balloon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Desai, P; Caroprese, B; McKellar, H

    2014-06-01

    Purpose: To illustrate 25% reduction in CyberKnife prostate SBRT treatment times using a water filled rectal balloon. Methods: We perform prostate SBRT using a 3800cGy in 4 fraction regimen prescribed between 51% 59% iso-dose lines to 95% of PTV using a CyberKnife System. The resultant heterogeneous dosimetry is analogous to HDR dosimetry. Our patients are treated in a feet first supine position to decrease treatment couch sag and also to position the prostate anatomy closer to the robot. CT imaging is performed with a Radiadyne Immobiloc rectal balloon filled with 45-50cc water placed firmly inside the patient's rectum. A treatmentmore » plan is developed from this CT study using Multiplan. The patient is treated every other day for 4 days using the rectal balloon for each fraction. Gold fiducials previously implanted inside the prostate are used for tracking by the CyberKnife system. Results: Critical structures comprise the usual GU anatomy of bladder, rectum, urethra, femoral-heads along with emphasis on doses to anterior rectal wall and rectal mucosa. The water filled rectal balloon localizes the rectum, which enables the physician to accurately contour both anterior rectal wall, and rectal mucosa. The balloon also has a gas release valve enabling better patient comfort. Rectum localization enables the CyberKnife system to make fewer corrections resulting in fewer treatment interruptions and time lost to re-adjustment for rectal motion, bowel filling and gas creation. Effective treatment times are reduced by 25% to approximately 45 minutes. Adoption of the balloon has required minimal change to our planning strategy and plan evaluation process. Conclusion: Patient follow-up comparisons show no difference in effectiveness of treatment with and without balloons We conclude that rectal balloons enhance patient comfort and decrease effective treatment times.« less

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santoro, J; Witten, M; Haas, J

    Purpose: Brachytherapy has been the standard of care for cervical cancer for 100 years. The treatment can be administered using an HDR (high dose rate) remote afterloader with a {sup 192}Ir source in an outpatient setting, a PDR afterloader with a {sup 192}Ir source, or with LDR manually loaded or a remote afterloader utilizing {sup 192}Ir or {sup 137}Cs sources in an inpatient setting. The procedure involves the placement of a tandem and ovoid, tandem and ring, or tandem and cylinder applicator in an operating room setting with the patient under general anesthesia. Inaccuracies introduced into the process occurring betweenmore » placement of the applicator and actual delivery can introduce uncertainty into the actual dose delivered to the tumor and critical organs. In this study we seek to investigate the dosimetric difference between an SBRT-based radiotherapy boost and conventional Brachytherapy in treating cervical cancer. Methods: Five HDR tandem and ovoid patients were planned using the Brachyvision treatment planning system and treated in four fractions using the Varian Varisource afterloader (Varian Medical Systems). For the same cohort, the patient planning CTs were imported into Multiplan (Accuray Inc) and a dose/fractionation-equivalent CyberKnife SBRT plan was retrospectively generated. Dosimetric quantities such as target/CTV D90, V90, D2cc for rectum, bladder, and bowel were measured and compared between the two modalities. Results: The CTV D90 for the tandem and ovoid was 2540cGy (90.7%) and 3009cGy (107.5%) for the CyberKnife plan. The D2cc for the rectum, bladder, and bowel were 1576cGy, 1641cGy, and 996cGy for the tandem and ovoid and 1374cGy, 1564cGy, and 1547cGy for CyberKnife. Conclusion: The D2cc doses to critical structures are comparable in both modalities. The CTV coverage is far superior for the CyberKnife plan. The dose distribution for CyberKnife has the advantage of increased conformality and lower maximum CTV dose.« less

  8. Substantiation of basic scheme of grain cleaning machine for preparation of agricultural crops seeds

    NASA Astrophysics Data System (ADS)

    Giyevskiy, A. M.; Orobinsky, V. I.; Tarasenko, A. P.; Chernyshov, A. V.; Kurilov, D. O.

    2018-03-01

    The article presents data on the feasibility of the concept of a high-efficiency seed cleaner with the consistent use of the air flow in aspiration and the multi-tier placement of the sorting grids in grating mills. As a result of modeling, the directions for further improvement of air-screen seed cleaning machines have been identified: an increase in the proportion of sorting grids in the mills up to 70 ... 80% and an increase in the speed of the air flow in the channel of the pre-filter cleaning up to 8.0 m / s. Experiments have established the competence of using mathematical modeling of airflow in the pneumatic system with the use of a finite-volume method for solving hydrodynamic equations for substantiating the basic parameters of the pneumatic system.

  9. Anti-quorum sensing activity of medicinal plants in southern Florida.

    PubMed

    Adonizio, Allison L; Downum, Kelsey; Bennett, Bradley C; Mathee, Kalai

    2006-05-24

    Bacterial intercellular communication, or quorum sensing (QS), controls the pathogenesis of many medically important organisms. Anti-QS compounds are known to exist in marine algae and have the ability to attenuate bacterial pathogenicity. We hypothesized that terrestrial plants traditionally used as medicines may also produce anti-QS compounds. To test this hypothesis, 50 medicinal plants from southern Florida were screened for anti-QS activity using two biomonitor strains, Chromobacterium violaceum and Agrobacterium tumefaciens. Of these plants, six showed QS inhibition: Conocarpus erectus L. (Combretaceae), Chamaecyce hypericifolia (L.) Millsp. (Euphorbiaceae), Callistemon viminalis (Sol. ex Gaertn.) G. Don (Myrtaceae), Bucida burceras L. (Combretaceae), Tetrazygia bicolor (Mill.) Cogn. (Melastomataceae), and Quercus virginiana Mill. (Fagaceae). This study introduces not only a new mode of action and possible validation for traditional plant use, but also a potentially new therapeutic direction for the treatment of bacterial infections.

  10. The Northern Cheyenne Exodus: A Reappraisal of the Army’s Response

    DTIC Science & Technology

    2015-06-12

    his band into the Bighorn Mountains. They eventually surrendered at Camp Robinson, Nebraska in April 1877. Little Wolf , like Dull Knife, was a Dog ...Soldier. He later left the Dog Soldiers and became head chief of the Elk Horn Scrapers. Little Wolf , also known as Two Tails, was born around 1830...Dull Knife and Little Wolf grew up in a culture that placed great value on bravery and being a warrior. That is why they became Dog Soldiers and Elk

  11. Successful removal of hyperkeratotic-lichenoid reaction to red ink tattoo with preservation of the whole tattoo using a skin grafting knife.

    PubMed

    Mlakar, Boštjan

    2015-01-01

    With the increasing popularity of tattoo body decorations, reports of medical complications with tattoos have increased in parallel. Although tattoo reactions can resolve spontaneously, they often last for months or even years, despite the various treatment methods. In our case, we present the successful removal of hyperkeratotic-lichenoid reaction to red ink using a simple and cheap skin grafting knife. The entire tattoo was preserved with a good aesthetic result with minimal scarring.

  12. Effect of subcutaneous Meloxicam on indicators of acute pain and distress after castration and branding in 2 mo old beef calves.

    PubMed

    Meléndez, D M; Marti, S; Pajor, E A; Moya, D; Gellatly, D; Janzen, E D; Schwartzkopf-Genswein, K S

    2018-06-15

    The aim of this study was to assess knife castration and knife castration + branding in 2-mo old calves, and the effect of a single dose of s.c. meloxicam at mitigating pain indicators. Seventy-one Angus crossbred bull calves (128 ± 18.5 kg of BW) were used in a 3 × 2 factorial design where main factors included procedure: sham (control calves, CT; n = 23), knife (KN; n = 24) or knife + branding (BK; n = 24) and medication: single s.c. administration of lactated ringer solution (NM; n = 35) or a single dose of 0.5 mg/kg of s.c. meloxicam (M; n = 36). Physiological samples were collected at T0, 60, 90, 120 and 180 min and on d 1, 2, 3 and 7 after procedure, while behavioral observations were evaluated at 2 to 4 h and 1, 2, 3 and 7 days after procedure. A procedure × time effect (P < 0.01) was observed for cortisol, where KN and BK calves had greater (P ≤ 0.01 ) cortisol concentrations than CT calves 60 min after the procedure, while BK calves had the greatest (P < 0.05) cortisol concentrations, followed by KN calves and by CT calves 90, 120 and 180 min after the procedure. A procedure × time effect (P = 0.01) was observed for tail flicks, where KN and BK calves had a greater (P < 0.05) number of tail flicks than CT calves on d 1 and 3, while BK calves had the greatest number of tail flicks, followed by KN calves, and then by CT calves on d 2. Haptoglobin had a procedure × medication × time interaction (P = 0.05), where BK-NM calves had greater haptoglobin concentrations than BK-M, KN-M and CT calves on d 1 and 3, while BK-NM and KN-NM calves had greater haptoglobin concentrations than BK-M, KN-M and CT calves on d 2 after the procedure. Lying duration and tail flicks had a medication effect (P = 0.04; P < 0.01) where M calves had greater (P < 0.05) lying duration and lower (P < 0.05) number of tail flicks than NM calves 2 to 4 h after procedure. No medication effects (P > 0.10) were observed for salivary cortisol, substance P and scrotal temperature min after the procedure or for cortisol, substance P, serum amyloid A, stride length or behavioral observations on d after the procedure. Overall, BK calves presented greater physiological and behavioral indicators of acute pain than KN calves, suggesting that the combination of knife castration + branding was more painful. Meloxicam administered s.c. was effective at reducing physiological and behavioral indicators of acute pain associated with knife castration and knife castration + branding.

  13. Integrated use of residues from olive mill and winery for lipase production by solid state fermentation with Aspergillus sp.

    PubMed

    Salgado, José Manuel; Abrunhosa, Luís; Venâncio, Armando; Domínguez, José Manuel; Belo, Isabel

    2014-02-01

    Two-phase olive mill waste (TPOMW) is presently the major waste produced by the olive mill industry. This waste has potential to be used as substrate for solid state fermentation (SSF) despite of its high concentration of phenolic compounds and low nitrogen content. In this work, it is demonstrated that mixtures of TPOMW with winery wastes support the production of lipase by Aspergillus spp. By agar plate screening, Aspergillus niger MUM 03.58, Aspergillus ibericus MUM 03.49, and Aspergillus uvarum MUM 08.01 were chosen for lipase production by SSF. Plackett-Burman experimental design was employed to evaluate the effect of substrate composition and time on lipase production. The highest amounts of lipase were produced by A. ibericus on a mixture of TPOMW, urea, and exhausted grape mark (EGM). Urea was found to be the most influent factor for the lipase production. Further optimization of lipase production by A. ibericus using a full factorial design (3(2)) conducted to optimal conditions of substrate composition (0.073 g urea/g and 25 % of EGM) achieve 18.67 U/g of lipolytic activity.

  14. Antibacterial activity of crude extracts of some South African medicinal plants against multidrug resistant etiological agents of diarrhoea.

    PubMed

    Bisi-Johnson, Mary A; Obi, Chikwelu L; Samuel, Babatunde B; Eloff, Jacobus N; Okoh, Anthony I

    2017-06-19

    This study evaluated the antibacterial activity of some plants used in folklore medicine to treat diarrhoea in the Eastern Cape Province, South Africa. The acetone extracts of Acacia mearnsii De Wild., Aloe arborescens Mill., A. striata Haw., Cyathula uncinulata (Schrad.) Schinz, Eucomis autumnalis (Mill.) Chitt., E. comosa (Houtt.) Wehrh., Hermbstaedtia odorata (Burch. ex Moq.) T.Cooke, Hydnora africana Thunb, Hypoxis latifolia Wight, Pelargonium sidoides DC, Psidium guajava L and Schizocarphus nervosus (Burch.) van der Merwe were screened against Staphylococcus aureus, Escherichia coli, Enterococcus faecalis, multi-resistant Salmonella enterica serovar Isangi, S. typhi, S. enterica serovar Typhimurium, Shigella flexneri type 1b and Sh. sonnei phase II. A qualitative phytochemical screening of the plants extracts was by thin layer chromatography. Plants extracts were screened for antibacterial activity using serial dilution microplate technique and bioautography. The TLC fingerprint indicated the presence of terpenoids and flavonoids in the herbs. Most of the tested organisms were sensitive to the crude acetone extracts with minimum inhibitory concentration (MIC) values ranging from 0.018-2.5 mg/mℓ. Extracts of A. striata, C. uncinulata, E. autumnalis and P. guajava were more active against enteropathogens. S. aureus and Sh. flexneri were the most sensitive isolates to the crude extracts but of significance is the antibacterial activity of A. arborescens and P. guajava against a confirmed extended spectrum betalactamase positive S. enterica serovar Typhimurium. The presence of bioactive compounds and the antibacterial activity of some of the selected herbs against multidrug resistant enteric agents corroborate assertions by traditional healers on their efficacies.

  15. Atom-optics knife-edge: Measuring sub-nanokelvin momentum distributions

    NASA Astrophysics Data System (ADS)

    Ramos, Ramon; Spierings, David; Steinberg, Aephraim

    2017-04-01

    Temperatures below 1 nanokelvin have been achieved in the recent years, enabling new classes of experiments which benefit from the resulting long coherence times. This achievement comes hand in hand with the challenge of measuring such low temperatures. By employing the equivalent of a knife-edge measurement for matter-waves, we have been able to characterize ultra-low momentum widths. We measured a momentum width corresponding to an effective temperature of 900 +/- 200 pK, only limited by our cooling performance. We show that this technique compares favourably with more traditional methods, which would require expansion times of 100's of ms or frequency stability of 10's of Hz. Finally, we show that the effective knife-edge, created by a potential barrier, begins to become ''blunt'' due to tunneling for thin barriers, and we obtain quantitative agreement with a theoretical model. This method is a useful tool for atomic interferometry and other areas in ultracold atoms where a robust and precise technique for characterizing the momentum distribution is required.

  16. Sinusoidal Forcing of Interfacial Films

    NASA Astrophysics Data System (ADS)

    Rasheed, Fayaz; Raghunandan, Aditya; Hirsa, Amir; Lopez, Juan

    2015-11-01

    Fluid transport, in vivo, is accomplished via pumping mechanisms of the heart and lungs, which results in biological fluids being subjected to oscillatory shear. Flow is known to influence biological macromolecules, but predicting the effect of shear is incomplete without also accounting for the influence of complex interfaces ubiquitous throughout the body. Here, we investigated the oscillatory response of the structure of aqueous interfacial films using a cylindrical knife edge viscometer. Vitamin K1 was used as a model monolayer because its behaviour has been thoroughly quantified and it doesn't show any measurable hysteresis. The monolayer was subjected to sinusoidal forcing under varied conditions of surface concentrations, periodic frequencies, and knife edge amplitudes. Particle Image Velocimetry(PIV) data was collected using Brewster Angle Microscopy(BAM), revealing the influence of oscillatory interfacial shear stress on the monolayer. Insights were gained as to how the velocity profile dampens at specific distances from the knife edge contact depending on the amplitude, frequency, and concentration of Vitamin K1. Supported by NNX13AQ22G, National Aeronautics and Space Administration.

  17. Cull sow knife-separable lean content evaluation at harvest and lean mass content prediction equation development.

    PubMed

    Abell, Caitlyn E; Stalder, Kenneth J; Hendricks, Haven B; Fitzgerald, Robert F

    2012-07-01

    The objectives of this study were to develop a prediction equation for carcass knife-separable lean within and across USDA cull sow market weight classes (MWC) and to determine carcass and individual primal cut knife separable lean content from cull sows. There were significant percent lean and fat differences in the primal cuts across USDA MWC. The two lighter USDA MWC had a greater percent carcass lean and lower percent fat compared to the two heavier MWC. In general, hot carcass weight explained the majority of carcass lean variation. Additionally, backfat was a significant variation source when predicting cull sow carcass lean. The findings support using a single lean prediction equation across MWC to assist processors when making cull sow purchasing decisions and determine the mix of animals from various USDA MWC that will meet their needs when making pork products with defined lean:fat content. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Fixed Full Arches Supported by Tapered Implants with Knife-Edge Thread Design and Nanostructured, Calcium-Incorporated Surface: A Short-Term Prospective Clinical Study

    PubMed Central

    Bechara, Soheil; Lukosiunas, Algirdas; Kubilius, Ricardas

    2017-01-01

    Purpose. To evaluate implant survival, peri-implant bone loss, and complications affecting fixed full-arch (FFA) restorations supported by implants with a knife-edge thread design and nanostructured, calcium-incorporated surface. Methods. Between January 2013 and December 2015, all patients referred for implant-supported FFA restorations were considered for enrollment in this study. All patients received implants with a knife-edge thread design and nanostructured calcium-incorporated surface (Anyridge®, Megagen, South Korea) were restored with FFA restorations and enrolled in a recall program. The final outcomes were implant survival, peri-implant bone loss, biologic/prosthetic complications, and “complication-free” survival of restorations. Results. Twenty-four patients were selected. Overall, 215 implants were inserted (130 maxilla, 85 mandible), 144 in extraction sockets and 71 in healed ridges. Thirty-six FFAs were delivered (21 maxilla, 15 mandible): 27 were immediately loaded and 9 were conventionally loaded. The follow-up ranged from 1 to 3 years. Two fixtures failed, yielding an implant survival rate of 95.9% (patient-based). A few complications were registered, for a “complication-free” survival of restorations of 88.9%. Conclusions. FFA restorations supported by implants with a knife-edge thread design and nanostructured, calcium-incorporated surface are successful in the short term, with high survival and low complication rates; long-term studies are needed to confirm these outcomes. PMID:28246595

  19. SU-F-P-15: Report On AAPM TG 178 Gamma Knife Dosimetry and Quality Assurance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goetsch, S

    Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocolmore » modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers Conclusion: The full TG 178 report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics. Consultant to Elekta, Inc.« less

  20. Analysis and Optimization of the Production Process of Cooked Sausage Meat Matrices

    NASA Astrophysics Data System (ADS)

    Diez, L.; Rauh, C.; Delgado, A.

    2010-09-01

    In the production of cooked sausages a critical step for product quality is the cutting process, where the comminuting and mixing of meat, fat, ice and spices are carried out. These processes take usually place in bowl cutters, which main control parameters are the working time, knife geometry (shape and sharpness) and rotational velocities of the knives and the bowl. The choice of the geometry and sharpness of the knives influences not only the meat matrix properties (mechanical, rheological, etc.) and, as a consequence, the sensory value of the sausages (size of connective tissue particles, water binding, etc.), but also the energetic demand for the production. However, the cutting process proves to be understood only fragmentarily due to the complex colloid chemical and mechanical behavior of the product. This is documented on the one hand by numerous knife types on the market, extremely empirical approach during determination of geometry and process parameters in practice as well as, on the other hand, by contradictory statements and explanation approaches of observed phenomena present in literature. The present contribution applies numerical simulations to analyze thermo fluid mechanical phenomena, e.g. shear stresses, during the cutting process of the non-Newtonian meat matrix. Combining these results with selected experimental investigations from literature, e.g. sensory properties, knife geometry, velocity of the knife and bowl, improvements of the cutting and mixing process are proposed using cognitive algorithms (Artificial neural networks) aiming at an optimization regarding energy and time demand and product quality.

  1. A novel device for endoscopic submucosal dissection, the Fork knife

    PubMed Central

    Kim, Hyun Gun; Cho, Joo Young; Bok, Gene Hyun; Cho, Won Young; Kim, Wan Jung; Hong, Su Jin; Ko, Bong Min; Kim, Jin Oh; Lee, Joon Seong; Lee, Moon Sung; Shim, Chan Sup

    2008-01-01

    AIM: To introduce and evaluate the efficacy and technical aspects of endoscopic submucosal dissection (ESD) using a novel device, the Fork knife. METHODS: From March 2004 to April 2008, ESD was performed on 265 gastric lesions using a Fork knife (Endo FS®) (group A) and on 72 gastric lesions using a Flexknife (group B) at a single tertiary referral center. We retrospectively compared the endoscopic characteristics of the tumors, pathological findings, and sizes of the resected specimens. We also compared the en bloc resection rate, complete resection rate, complications, and procedure time between the two groups. RESULTS: The mean size of the resected specimens was 4.27 ± 1.26 cm in group A and 4.29 ± 1.48 cm in group B. The en bloc resection rate was 95.8% (254/265 lesions) in group A and 93.1% (67/72) in group B. Complete ESD without tumor cell invasion of the resected margin was obtained in 81.1% (215/265) of group A and in 73.6% (53/72) of group B. The perforation rate was 0.8% (2/265) in group A and 1.4% (1/72) in group B. The mean procedure time was 59.63 ± 56.12 min in group A and 76.65 ± 70.75 min in group B (P < 0.05). CONCLUSION: The Fork knife (Endo FS®) is useful for clinical practice and has the advantage of reducing the procedure time. PMID:19034979

  2. Double Intracavernous Breakage of Sachse's Knife Blade: Management of a Rare Complication Performing Direct Vision Internal Urethrotomy.

    PubMed

    Benincasa, Alfonso; Saita, Alberto; Pinto, Angelo; Pilerci, Carmine; Francesco, Lamberti; Russo, Aniello; Benincasa, Giuseppe

    2017-01-01

    Background: Although the breakage of a Sachse's knife blade is already a rare event while performing optical internal urethrotomy, a double failure appears to be at the same time a unique and a challenging complication to manage since no reference has emerged from literature review. Case Presentation: A male patient, 80 years of age, underwent retreatment of recurrent urethral stricture that occurred after transurethral resection of the prostate. The latter was complicated by severe intraoperative urethrorrhagia; this is the reason he was transferred from another institution where at first a suprapubic cystostomy was carried out, followed by urethral recanalization through internal urethrotomy and finally he underwent intracavernous Sachse's knife blade discharge. Preoperative evaluation included combined retrograde and voiding urethrography and CT to evaluate the complete resolution of the urethral stenosis and to establish the correct location of the blades inside the corpus cavernosum. A transperineal approach to the left corpus cavernosum was carried out with manageable removal of the foreign body and postoperative assessment showed no early considerable complications for the patient. Conclusion: To our knowledge, this is the first case of double breakage of Sachse's knife blade performing optical internal urethrotomy reported in literature. Although it may appear to be an easy procedure, close attention to its execution must always be paid to prevent major complications. A transperineal approach has proven to be effective and safe without creating any further outcomes to the patient.

  3. Intravascular Placement of Metallic Coils as Lung Tumor Markers for CyberKnife Stereotactic Radiation Therapy.

    PubMed

    Karaman, Kutlay; Dokdok, A Murat; Karadeniz, Oktay; Ceylan, Cemile; Engin, Kayıhan

    2015-01-01

    To present our experience with placing endovascular coils in pulmonary arteries used as a fiducial marker for CyberKnife therapy and to describe the technical details and complications of the procedure. Between June 2005 and September 2013, 163 patients with primary or secondary lung malignancies, referred for fiducial placement for stereotactic radiosurgery, were retrospectively reviewed. Fourteen patients (9 men, 5 women; mean age, 70 years) with a history of pneumonectomy (n = 3), lobectomy (n = 3) or with severe cardiopulmonary co-morbidity (n = 8) underwent coil (fiducial marker) placement. Pushable or detachable platinum micro coils (n = 49) 2-3 mm in size were inserted through coaxial microcatheters into a small distal pulmonary artery in the vicinity of the tumor under biplane angiography/fluoroscopy guidance. Forty nine coils with a median number of 3 coils per tumor were placed with a mean tumor-coil distance of 2.7 cm. Forty three (87.7%) of 49 coils were successfully used as fiducial markers. Two coils could not be used due to a larger tumor-coil distance (> 50 mm). Four coils were in an acceptable position but their non-coiling shape precluded tumor tracking for CyberKnife treatment. No major complications needing further medication other than nominal therapy, hospitalization more than one night or permanent adverse sequale were observed. Endovascular placement of coil as a fiducial marker is safe and feasible during CyberKnife therapy, and might be an option for the patients in which percutaneous transthoracic fiducial placement might be risky.

  4. Screening of freshwater and seawater microalgae strains in fully controlled photobioreactors for biodiesel production.

    PubMed

    Taleb, A; Kandilian, R; Touchard, R; Montalescot, V; Rinaldi, T; Taha, S; Takache, H; Marchal, L; Legrand, J; Pruvost, J

    2016-10-01

    Strain selection is one of the primary hurdles facing cost-effective microalgal biodiesel production. Indeed, the strain used affects both upstream and downstream biodiesel production processes. This study presents a screening procedure that considers the most significant criteria in microalgal biodiesel production including TAG production and wet extraction and recovery of TAGs. Fourteen freshwater and seawater strains were investigated. Large variation was observed between the strains in all the screening criteria. The overall screening procedure ultimately led to the identification of Parachlorella kessleri UTEX2229 and Nannochloropsis gaditana CCMP527 as the best freshwater and seawater strains, respectively. They featured the largest areal TAG productivity equal to 2.7×10(-3) and 2.3×10(-3)kgm(-2)d(-1), respectively. These two strains also displayed encouraging cell fragility in a high pressure bead milling process with 69% and 98% cell disruption at 1750bar making them remarkable strains for TAG extraction in wet environment. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. [Stiletto needle and needle-knife for influence of gravity index in treating knee osteoarthritis].

    PubMed

    Gu, Li-Jun; Zhang, Bin; Li, Wen-Hua; Tang, Yan; Dong, Fu-Hui

    2017-12-25

    To explore stiletto needle and needle-knife for influence of double sufficient weight in treating knee osteoarthritis patients. One hundred and thirteen early and medium term knee osteoarthritis patients were randomly divided into three groups, including stiletto needle group(38 cases), needle-knife group (38 cases) and voltaren group (37 cases). In stiletto needle group, there were 13 males and 25 females with an average of(55.87±7.72) years old, treated by stiletto needle once a week, and 2 weeks were a course; there were 11 males and 27 females in needle-knife group with an average of(57.11±7.07) years old, treated by acupotome once a week, and 2 weeks were a course; there were 12 males and 25 females in voltaren group with an average age of(57.62±8.08) years old, treated by votalin emulsion smearing 3 to 5 cm on painful area of knee joint, three times a day for 2 weeks; 36 patients in normal group, including 11 males and 25 females with a mean age of (55.28±7.55) years old, treated with nothing. Gravitational four lattice used to measure bipedal back and forth load before and after treatment in further observe weight-bearing situation among three groups, d value, which was the distance from center of gravity to original point, was measured as a obvervational index, JOA score was used to evaluate clinical effect. Five patients were fall out, including 2 patients in stiletto needle group, 2 patients in needle-knife group and 1 patient in voltaren group. Other 108 patients were followed-up from 28 to 35 d with an average of 30 d, and without untoward effect. There was significant difference in d value between treatment group and control group at 1 month after treatment( P <0.05); there was significant difference in d value among treatment group at 1 month after treatment( P >0.05), and d value was decreased before treatment than that of after treatment. There was no significant difference in JOA score among treatment group after treatment at 1 month( P <0.05); while had significant difference between groups( P >0.05) after treatment at 1 month. Stiletto needle, needle-knife and voltaren for the treatment of knee osteoarthritis at early and middle stage, center of gravity is closer to original point, and weight-bearing is improved. It is a easy method of four lattice to measure change of weight-bearing in KOA patients after treatment.

  6. An Archaeological Survey: Shoreline of Lake Darling and Proposed Burlington Dam. Flood Control Project Area, Upper Souris River, North Dakota

    DTIC Science & Technology

    1978-01-01

    glacial melt waters. The valley north of the confluence of the Des Lacs River is incised to an average depth of 48 meters (Lemke 1960:7). Average stream...near New Town, North Dakota, We did view a catlinite tablet incised with an anthropomorphic stick figure. This specimen came from 32RV411. There has been...collected from the site includes: 1) Two Knife River flint bifaces 2) One Aquamarine incised trade bead 3) Two flakes: one of Knife River flint one of agate

  7. VIEW OF TRANSFER CAR (BATTERYELECTRIC POWERED) FROM BILLET YARD POSITIONED ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF TRANSFER CAR (BATTERY-ELECTRIC POWERED) FROM BILLET YARD POSITIONED FOR LOADING BILLETS INTO FURNACE; HEATER (BEHIND SCREEN IN CENTER) MOVES THE TRANSFER CAR INTO POSITION. BILLETS FROM THE TRANSFER CAR ARE PLACED ON HAND-OPERATED TURNTABLE. THE FURNACE IS NATURAL-GAS FIRED, WITH BILLETS HEATED AT NOT MORE THAN 2400 DEGREES FAHRENHEIT. - Cambria Iron Company, Gautier Works, 12" Mill, Clinton Street & Little Conemaugh River, Johnstown, Cambria County, PA

  8. Particle Morphology Analysis of Biomass Material Based on Improved Image Processing Method

    PubMed Central

    Lu, Zhaolin

    2017-01-01

    Particle morphology, including size and shape, is an important factor that significantly influences the physical and chemical properties of biomass material. Based on image processing technology, a method was developed to process sample images, measure particle dimensions, and analyse the particle size and shape distributions of knife-milled wheat straw, which had been preclassified into five nominal size groups using mechanical sieving approach. Considering the great variation of particle size from micrometer to millimeter, the powders greater than 250 μm were photographed by a flatbed scanner without zoom function, and the others were photographed using a scanning electron microscopy (SEM) with high-image resolution. Actual imaging tests confirmed the excellent effect of backscattered electron (BSE) imaging mode of SEM. Particle aggregation is an important factor that affects the recognition accuracy of the image processing method. In sample preparation, the singulated arrangement and ultrasonic dispersion methods were used to separate powders into particles that were larger and smaller than the nominal size of 250 μm. In addition, an image segmentation algorithm based on particle geometrical information was proposed to recognise the finer clustered powders. Experimental results demonstrated that the improved image processing method was suitable to analyse the particle size and shape distributions of ground biomass materials and solve the size inconsistencies in sieving analysis. PMID:28298925

  9. Establishing a process of irradiating small animal brain using a CyberKnife and a microCT scanner

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Haksoo; Welford, Scott; Fabien, Jeffrey

    2014-02-15

    Purpose: Establish and validate a process of accurately irradiating small animals using the CyberKnife G4 System (version 8.5) with treatment plans designed to irradiate a hemisphere of a mouse brain based on microCT scanner images. Methods: These experiments consisted of four parts: (1) building a mouse phantom for intensity modulated radiotherapy (IMRT) quality assurance (QA), (2) proving usability of a microCT for treatment planning, (3) fabricating a small animal positioning system for use with the CyberKnife's image guided radiotherapy (IGRT) system, and (4)in vivo verification of targeting accuracy. A set of solid water mouse phantoms was designed and fabricated, withmore » radiochromic films (RCF) positioned in selected planes to measure delivered doses. After down-sampling for treatment planning compatibility, a CT image set of a phantom was imported into the CyberKnife treatment planning system—MultiPlan (ver. 3.5.2). A 0.5 cm diameter sphere was contoured within the phantom to represent a hemispherical section of a mouse brain. A nude mouse was scanned in an alpha cradle using a microCT scanner (cone-beam, 157 × 149 pixels slices, 0.2 mm longitudinal slice thickness). Based on the results of our positional accuracy study, a planning treatment volume (PTV) was created. A stereotactic body mold of the mouse was “printed” using a 3D printer laying UV curable acrylic plastic. Printer instructions were based on exported contours of the mouse's skin. Positional reproducibility in the mold was checked by measuring ten CT scans. To verify accurate dose delivery in vivo, six mice were irradiated in the mold with a 4 mm target contour and a 2 mm PTV margin to 3 Gy and sacrificed within 20 min to avoid DNA repair. The brain was sliced and stained for analysis. Results: For the IMRT QA using a set of phantoms, the planned dose (6 Gy to the calculation point) was compared to the delivered dose measured via film and analyzed using Gamma analysis (3% and 3 mm). A passing rate of 99% was measured in areas of above 40% of the prescription dose. The final inverse treatment plan was comprised of 43 beams ranging from 5 to 12.5 mm in diameter (2.5 mm size increments are available up to 15 mm in diameter collimation). Using the Xsight Spine Tracking module, the CyberKnife system could not reliably identify and track the tiny mouse spine; however, the CyberKnife system could identify and track the fiducial markers on the 3D mold.In vivo positional accuracy analysis using the 3D mold generated a mean error of 1.41 mm ± 0.73 mm when fiducial markers were used for position tracking. Analysis of the dissected brain confirmed the ability to target the correct brain volume. Conclusions: With the use of a stereotactic body mold with fiducial markers, microCT imaging, and resolution down-sampling, the CyberKnife system can successfully perform small-animal radiotherapy studies.« less

  10. [Effects of small needle knife on the substance P in the dorsal root ganglion and spinal cord of rats].

    PubMed

    Wang, Jin-Rong; Wang, Yong-Zhi; Dong, Fu-Hui; Zhong, Hong-Gang; Wang, De-Long; Wang, Xuan

    2010-09-01

    To study the mechanism of synthesis of substance P (SP) in the dorsal root ganglion (DRG) and the release of it in the dorsal horn of the spinal cord of rats after compression of skeletal muscle, and to observe the influence of small needle knife. Sustained pressure of 70 kPa was applied to rats, muscular tissues for 2 hours. The rats were divided into three groups: normal, control and experiment group respectively. In all rats except the six normal ones, the lower legs were compressed once one day. The left leg was considered as the control group, the right left was experiment group, which were divided into the 1st day, the 2nd day and the 3rd day within the two groups. Experiment group was treated with small needle knife after the muscular tissue was compressed. After completing the stimulation, the DRG related to the muscle and part of spinal cord were removed for the qualification of SP-like immunoreactivity using immunohistochemistry. The dark brown stains on the DRG and on the REXed laminae I and II in the dorsal horn of the spinal cord were counted by Image-Pro Plus software. SP-like immunoreactivity in the side treated by the small needle knife was enhanced comparing with the counterpart in DRG in normal group (P < 0.01). The integrated optical density of SP like immunoreactivity of the DRG in the experiment group were significantly reduced compared with the control group (P < 0.05). However, the release of SP from spinal cord in experiment group was lower than that in the control group at the 1st day and the 3rd day (P < 0.01), with the opposite result of the 2nd day. Based on the fact that SP is a nociceptive neurotransmitter, the present study suggests that tension relaxation by small needle knife reduces expression of SP in the DRG, and shows no effects on the release of SP from the spinal cord in short-term (3 days).

  11. Gamma Knife radiosurgery for intracranial meningiomas: Do we need to treat the dural tail? A single-center retrospective analysis and an overview of the literature.

    PubMed

    Bulthuis, Vincent J; Hanssens, Patrick E J; Lie, Suan Te; van Overbeeke, Jacobus J

    2014-01-01

    The dural tail (DT) has been described as a common feature in meningiomas. There is a great variation of tumor invasion and extent of tumor cells in the DT. Therefore, the necessity to include the whole DT in Gamma Knife radiosurgery is not clear, since inclusion increases the target volume and therefore increases the risk of complications. In this analysis, we evaluated whether the complete tail should be included as part of the target in Gamma Knife radiosurgery for meningiomas. Between June 2002 and December 2010, Gamma Knife radiosurgery was performed in 160 patients with 203 meningiomas with a DT. In 105 tumors, the diagnosis was based on magnetic resonance imaging (MRI) characteristics, and in 98 tumors, the diagnosis was confirmed by histopathologic examination after surgery. The median volume of the tumors was 3.55 cc. All tumors were treated with Gamma Knife radiosurgery with a median prescribed dose of 13 Gy (range 11-15), resulting in a median marginal dose of 11 Gy (range 10-15). Only the part of the DT closely related to the tumor mass was included in the target. The median follow-up period was 41 months (range 12-123). In image-based meningiomas, the overall local control rate was 96.2% with 2- and 5-year control rates of 98.0% and 95.1%, respectively. In WHO grade I tumors, the overall local control rate was 85.9% with 2- and 5-year control rates of 94.5% and 88.0%, respectively. The overall local control rate in World Health Organization (WHO) grade II tumors was 70.6% with control rates of 83.4% and 64.4% after 2 and 5 years, respectively. The growth of all new tumors was found in the radiation target area. No tumor growth was observed in the part of the DT that had been excluded from the target volume. We found in this study that routinely excluding the DT from the target does not lead to out-of-field tumor progression. Given the possibility that the DT is infiltrated with tumor cells, regular follow-up is needed.

  12. Multistage stereotactic radiosurgery for large cerebral arteriovenous malformations using the Gamma Knife platform.

    PubMed

    Ding, Chuxiong; Hrycushko, Brian; Whitworth, Louis; Li, Xiang; Nedzi, Lucien; Weprin, Bradley; Abdulrahman, Ramzi; Welch, Babu; Jiang, Steve B; Wardak, Zabi; Timmerman, Robert D

    2017-10-01

    Radiosurgery is an established technique to treat cerebral arteriovenous malformations (AVMs). Obliteration of larger AVMs (> 10-15 cm 3 or diameter > 3 cm) in a single session is challenging with current radiosurgery platforms due to toxicity. We present a novel technique of multistage stereotactic radiosurgery (SRS) for large intracranial arteriovenous malformations (AVM) using the Gamma Knife system. Eighteen patients with large (> 10-15 cm 3 or diameter > 3 cm) AVMs, which were previously treated using a staged SRS technique on the Cyberknife platform, were retrospectively selected for this study. The AVMs were contoured and divided into 3-8 subtargets to be treated sequentially in a staged approach at half to 4 week intervals. The prescription dose ranged from 15 Gy to 20 Gy, depending on the subtarget number, volume, and location. Gamma Knife plans using multiple collimator settings were generated and optimized. The coordinates of each shot from the initial plan covering the total AVM target were extracted based on their relative positions within the frame system. The shots were regrouped based on their location with respect to the subtarget contours to generate subplans for each stage. The delivery time of each shot for a subtarget was decay corrected with 60 Co for staging the treatment course to generate the same dose distribution as that planned for the total AVM target. Conformality indices and dose-volume analysis were performed to evaluate treatment plans. With the shot redistribution technique, the composite dose for the multistaged treatment of multiple subtargets is equivalent to the initial plan for total AVM target. Gamma Knife plans resulted in an average PTV coverage of 96.3 ± 0.9% and a PITV of 1.23 ± 0.1. The resulting Conformality indices, V 12Gy and R 50 dose spillage values were 0.76 ± 0.05, 3.4 ± 1.8, and 3.1 ± 0.5 respectively. The Gamma Knife system can deliver a multistaged conformal dose to treat large AVMs when correcting for translational setup errors of each shot at each staged treatment. © 2017 American Association of Physicists in Medicine.

  13. Hypertrophic olivary degeneration following surgical resection or gamma knife radiosurgery of brainstem cavernous malformations: an 11-case series and a review of literature.

    PubMed

    Yun, Jung-Ho; Ahn, Jae Sung; Park, Jung Cheol; Kwon, Do Hoon; Kwun, Byung Duk; Kim, Chang Jin

    2013-03-01

    We describe 11 patients with hypertrophic olivary degeneration (HOD) after surgical resection or gamma knife radiosurgery for brainstem cavernous malformations. In addition, we statistically analyzed the predicting factors associated with the development of HOD. From January 2001 to May 2011, a total of 73 patients (30 in the surgical group and 43 in the radiosurgery group) with brainstem cavernous malformations were treated in our institute. Of them, 11 patients (incidence: 15 %) developed HOD with high signal intensity on T2-weighted MRI during follow-up. The predicting factors (location, size, age, and treatment method) associated with the development of HOD were statistically analyzed. Among the 11 HOD patients, seven patients received surgical resection and four patients received gamma knife radiosurgery. Six patients had bilateral HOD and the remaining five patients had unilateral HOD. Overall HOD-associated symptoms presented in four patients, including three palatal tremors and one ataxia. In all four patients with symptoms, these symptoms disappeared incompletely within the clinical follow-up period. The size of the cavernous malformation, age of patient, and treatment methods were not significantly correlated with the development of HOD. A significantly higher incidence of HOD was associated with midbrain cavernous malformations than with pontine or medulla cavernous malformations. HOD should be recognized as a non-infrequent complication of surgical resection or gamma knife radiosurgery within the brainstem, especially for midbrain cavernous malformations. In addition, to the best of our knowledge, this is the first report on HOD development after radiosurgery.

  14. Safety and efficacy of pancreatic sphincterotomy in chronic pancreatitis.

    PubMed

    Ell, C; Rabenstein, T; Schneider, H T; Ruppert, T; Nicklas, M; Bulling, D

    1998-09-01

    Endoscopic pancreatic sphincterotomy (EPS) is being performed with increasing frequency as a prerequisite to interventional measures in the pancreatic duct. The aim of this study was to evaluate EPS with regard to technique, success, complications, and mortality in patients with chronic pancreatitis. Between January 1989 and September 1996, the results of all consecutive EPSs in patients with chronic pancreatitis were documented in a standardized form. Patients were followed by clinical investigation and blood sample analysis at 4, 24, and 48 hours after EPS. Complications were classified according to commonly accepted criteria. EPS was performed in 118 patients with chronic pancreatitis (men 75%, women 25%, 48+/-10 years). Ninety-four patients (80%) underwent guidewire-assisted EPS, and 24 patients (20%) underwent needle-knife EPS. Seventy-seven EPS procedures (65%) were primarily successful (guidewire EPS: 60 of 94, 64%; needle-knife EPS: 17 of 24, 71%). Additional endoscopic cutting techniques (needle-knife papillotomy, biliary endoscopic sphincterotomy) were required in 41 patients (35%). In total, EPS was successful in 116 patients (98%). The complication rate was 4.2% (4 cases of moderate pancreatitis, 1 severe bleeding, no deaths). All complications were managed nonoperatively. In patients with chronic pancreatitis, EPS with a standard sphincterotome or with a needle-knife offers an effective and reliable approach to the pancreatic duct system. Additional cutting techniques may be necessary in approximately one third of cases before an EPS can be successfully performed. The complication rate of EPS in patients with chronic pancreatitis appears to be lower than the complication rate of biliary sphincterotomy for other indications.

  15. Randomized clinical trial comparing cold knife conization of the cervix with and without lateral hemostatic sutures.

    PubMed

    Bueno, Letícia Rossi; Binda, Marcia; Monego, Heleusa; Scherer, Roberta Luísa; Rolim, Karen Machado; Bottini, Alessandra Leal; Fregnani, José H T G; dos Reis, Ricardo

    2015-06-01

    Compare blood loss during cold knife conization of the cervix with and without lateral hemostatic sutures in the cervical branches of the uterine arteries. Randomized clinical trial. Hospital de Clínicas de Porto Alegre (HCPA). 102 patients that underwent cold knife conization. Women that underwent cold knife conization of the cervix were randomized to undergo the procedure with or without lateral hemostatic sutures. blood loss measured in grams. operative time and postoperative intervention. Only the participants were blinded to group assignment. From March 2009 to August 2012, patients were randomly assigned to one of the study groups. There were no differences in amount of blood loss between patients that underwent the procedure with and without sutures (p = 0.39). Operative time was shorter in the group without suture (p = 0.020). There were no differences in intervention due to bleeding (p = 0.20). Blood loss was greater among menstruating women than for menopausal women (p = 0.011). There were no differences in amount of blood lost between smoking and nonsmoking patients (p = 0.082). Lateral hemostatic sutures do not affect the amount of intraoperative bleeding or the number of postoperative interventions. Their use is not necessary because they result in longer operative time, have a higher cost due to the use of suture material and pose the risk of ureter lesion in case the sutures are not placed at a lower position in the cervix. ClinicalTrials. gov identifier: NCT02184975. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  16. Contact lens-induced circumlimbal staining in silicone hydrogel contact lenses worn on a daily wear basis.

    PubMed

    Maïssa, Cécile; Guillon, Michel; Garofalo, Renee J

    2012-01-01

    The principal objective of the study was to measure the conjunctival staining produced in the circumlimbal region by silicone hydrogel contact lenses with different edge designs. The secondary objective was to investigate the association between circumlimbal staining and comfort. Four silicone hydrogel contact lenses: ACUVUE OASYS (knife edge design), AIR OPTIX, Biofinity (chisel edge rounded edge combination), and PureVision (rounded edge design), and 1 hydrogel contact lens, ACUVUE 2 (knife edge design), were tested. The study was conducted on a cohort population of 27 established soft contact lens wearers, who wore each contact lens type, in a random order, for a period of 10 (±2) days. Circumlimbal staining was measured in a double-masked fashion through image analysis of digital photographs of lissamine green taken under controlled experimental conditions. The results obtained showed that contact lens edge design was the primary factor controlling circumlimbal staining for silicone hydrogel lenses: a rounded edge away from the ocular surface produced the lowest staining (average, 0.19%) and a knife edge in close apposition to the ocular surface produced the highest staining (average, 1.34%). Contact lens material rigidity was also identified to affect circumlimbal staining and an inverse association between circumlimbal staining and contact lens comfort was demonstrated: the rounded edge design produced the lowest comfort (72 of 100) and the knife edge design produced the highest (87 out of 100). Soft contact lens wear induces circumlimbal staining, the level of staining being influenced by the contact lens edge design. However, high level of circumlimbal staining is not associated with decreased comfort.

  17. Mid-term prognosis of non-functioning pituitary adenomas with high proliferative potential: really an aggressive variant?

    PubMed

    Ogawa, Yoshikazu; Jokura, Hidefumi; Niizuma, Kuniyasu; Tominaga, Teiji

    2018-05-01

    Pituitary adenomas with high proliferation rate and rapid growth are well known, but the clinical characteristics, prognosis, and treatment algorithm remain unclear. The clinical characteristics and mid-term prognosis of patients with non-functioning pituitary adenomas with high proliferative potential were retrospectively investigated. This study identified 53 patients with Ki-67 labeling index of > 3% among 845 patients with non-functioning pituitary adenoma (6.3%) initially treated by surgery. Prophylactic treatment was not applied for patients with residual tumor, but salvage treatment was performed if tumor progression was identified within the follow-up period. Twenty-two patients remained progression-free, whereas 31 patients suffered tumor progression. Comparison of gross total removal (n = 22) and non-total removal (n = 31) groups showed significantly longer progression-free period in the former group (P < 0.001). As salvage treatment gamma knife radiosurgery was applied for 11 patients resulting in 10 patients remaining progression-free and regrowth in 1 patient. Fractionated irradiation was applied for 10 patients, resulting in 2 patients remaining progression-free, deaths in 5 patients including 3 of transformation to pituitary carcinoma, dementia in 1 patient caused by frontal lobe dysfunction, and progression in 2 patients requiring additional surgery and gamma knife radiosurgery. Temozolomide was administered in 2 patients, resulting in deaths in both patients including 1 transformation to pituitary carcinoma. Total removal and gamma knife radiosurgery can result in good outcome. However, the prognosis is extremely poor for patients inadequate for gamma knife radiosurgery. Development of new salvage treatments is essential.

  18. Endoscopic submucosal dissection for early esophageal neoplasms using the stag beetle knife

    PubMed Central

    Kuwai, Toshio; Yamaguchi, Toshiki; Imagawa, Hiroki; Miura, Ryoichi; Sumida, Yuki; Takasago, Takeshi; Miyasako, Yuki; Nishimura, Tomoyuki; Iio, Sumio; Yamaguchi, Atsushi; Kouno, Hirotaka; Kohno, Hiroshi; Ishaq, Sauid

    2018-01-01

    AIM To determine short- and long-term outcomes of endoscopic submucosal dissection (ESD) using the stag beetle (SB) knife, a scissor-shaped device. METHODS Seventy consecutive patients with 96 early esophageal neoplasms, who underwent ESD using a SB knife at Kure Medical Center and Chugoku Cancer Center, Japan, between April 2010 and August 2016, were retrospectively evaluated. Clinicopathological characteristics of lesions and procedural adverse events were assessed. Therapeutic success was evaluated on the basis of en bloc, histologically complete, and curative or non-curative resection rates. Overall and tumor-specific survival, local or distant recurrence, and 3- and 5-year cumulative overall metachronous cancer rates were also assessed. RESULTS Eligible patients had dysplasia/intraepithelial neoplasia (22%) or early cancers (squamous cell carcinoma, 78%). The median procedural time was 60 min and on average, the lesions measured 24 mm in diameter, yielding 33-mm tissue defects. The en bloc resection rate was 100%, with 95% and 81% of dissections deemed histologically complete and curative, respectively. All procedures were completed without accidental incisions/perforations or delayed bleeding. During follow-up (mean, 35 ± 23 mo), no local recurrences or metastases were observed. The 3- and 5-year survival rates were 83% and 70%, respectively, with corresponding rates of 85% and 75% for curative resections and 74% and 49% for non-curative resections. The 3- and 5-year cumulative rates of metachronous cancer in the patients with curative resections were 14% and 26%, respectively. CONCLUSION ESD procedures using the SB knife are feasible, safe, and effective for treating early esophageal neoplasms, yielding favorable short- and long-term outcomes. PMID:29686470

  19. Trans-umbilical endoscopic cholecystectomy with a water-jet hybrid-knife: A pilot animal study

    PubMed Central

    Jiang, Sheng-Jun; Shi, Hong; Swar, Gyanendra; Wang, Hai-Xia; Liu, Xiao-Jing; Wang, Yong-Guang

    2013-01-01

    AIM: To investigate the feasibility and safety of Natural orifice trans-umbilical endoscopic cholecystectomy with a water-jet hybrid-knife in a non-survival porcine model. METHODS: Pure natural orifice transluminal endoscopic surgery (NOTES) cholecystectomy was performed on three non-survival pigs, by transumbilical approach, using a water-jet hybrid-knife. Under general anesthesia, the following steps detailed the procedure: (1) incision of the umbilicus followed by the passage of a double-channel flexible endsocope through an overtube into the peritoneal cavity; (2) establishment of pneumoperitoneum; (3) abdominal exploration; (4) endoscopic cholecystectomy: dissection of the gallbladder performed using water jet equipment, ligation of the cystic artery and duct conducted using nylon loops; and (5) necropsy with macroscopic evaluation. RESULTS: Transumbilical endoscopic cholecystectomy was successfully completed in the first and third pig, with minor bleedings. The dissection times were 137 and 42 min, respectively. The total operation times were 167 and 69 min, respectively. And the lengths of resected specimen were 6.5 and 6.1 cm, respectively. Instillation of the fluid into the gallbladder bed produced edematous, distended tissue making separation safe and easy. Reliable ligation using double nylon loops insured the safety of cutting between the loops. There were no intraoperative complications or hemodynamic instability. Uncontrolled introperative bleeding occurred in the second case, leading to the operation failure. CONCLUSION: Pure NOTES trans-umbilical cholecystectomy with a water-jet hybrid-knife appears to be feasible and safe. Further investigation of this technique with long-term follow-up in animals is needed to confirm the preliminary observation. PMID:24187461

  20. Trans-umbilical endoscopic cholecystectomy with a water-jet hybrid-knife: a pilot animal study.

    PubMed

    Jiang, Sheng-Jun; Shi, Hong; Swar, Gyanendra; Wang, Hai-Xia; Liu, Xiao-Jing; Wang, Yong-Guang

    2013-10-28

    To investigate the feasibility and safety of Natural orifice trans-umbilical endoscopic cholecystectomy with a water-jet hybrid-knife in a non-survival porcine model. Pure natural orifice transluminal endoscopic surgery (NOTES) cholecystectomy was performed on three non-survival pigs, by transumbilical approach, using a water-jet hybrid-knife. Under general anesthesia, the following steps detailed the procedure: (1) incision of the umbilicus followed by the passage of a double-channel flexible endoscope through an overtube into the peritoneal cavity; (2) establishment of pneumoperitoneum; (3) abdominal exploration; (4) endoscopic cholecystectomy: dissection of the gallbladder performed using water jet equipment, ligation of the cystic artery and duct conducted using nylon loops; and (5) necropsy with macroscopic evaluation. Transumbilical endoscopic cholecystectomy was successfully completed in the first and third pig, with minor bleedings. The dissection times were 137 and 42 min, respectively. The total operation times were 167 and 69 min, respectively. And the lengths of resected specimen were 6.5 and 6.1 cm, respectively. Instillation of the fluid into the gallbladder bed produced edematous, distended tissue making separation safe and easy. Reliable ligation using double nylon loops insured the safety of cutting between the loops. There were no intraoperative complications or hemodynamic instability. Uncontrolled introperative bleeding occurred in the second case, leading to the operation failure. Pure NOTES trans-umbilical cholecystectomy with a water-jet hybrid-knife appears to be feasible and safe. Further investigation of this technique with long-term follow-up in animals is needed to confirm the preliminary observation.

  1. Technical Note: PRESAGE three-dimensional dosimetry accurately measures Gamma Knife output factors

    PubMed Central

    Klawikowski, Slade J.; Yang, James N.; Adamovics, John; Ibbott, Geoffrey S.

    2014-01-01

    Small-field output factor measurements are traditionally very difficult because of steep dose gradients, loss of lateral electronic equilibrium, and dose volume averaging in finitely sized detectors. Three-dimensional (3D) dosimetry is ideal for measuring small output factors and avoids many of these potential challenges of point and two-dimensional detectors. PRESAGE 3D polymer dosimeters were used to measure the output factors for the 4 mm and 8 mm collimators of the Leksell Perfexion Gamma Knife radiosurgery treatment system. Discrepancies between the planned and measured distance between shot centers were also investigated. A Gamma Knife head frame was mounted onto an anthropomorphic head phantom. Special inserts were machined to hold 60 mm diameter, 70 mm tall cylindrical PRESAGE dosimeters. The phantom was irradiated with one 16 mm shot and either one 4 mm or one 8 mm shot, to a prescribed dose of either 3 Gy or 4 Gy to the 50% isodose line. The two shots were spaced between 30 mm and 60 mm apart and aligned along the central axis of the cylinder. The Presage dosimeters were measured using the DMOS-RPC optical CT scanning system. Five independent 4 mm output factor measurements fell within 2% of the manufacturer’s Monte Carlo simulation-derived nominal value, as did two independent 8 mm output factor measurements. The measured distances between shot centers varied by ± 0.8 mm with respect to the planned shot displacements. On the basis of these results, we conclude that PRESAGE dosimetry is excellently suited to quantify the difficult-to-measure Gamma Knife output factors. PMID:25368961

  2. Safety and efficacy of endovascular therapy and gamma knife surgery for brain arteriovenous malformations in China: Study protocol for an observational clinical trial.

    PubMed

    Jin, Hengwei; Huo, Xiaochuan; Jiang, Yuhua; Li, Xiaolong; Li, Youxiang

    2017-09-01

    Brain arteriovenous malformations (BAVMs) are associated with high morbidity and mortality. The treatment of BAVM remains controversial. Microinvasive treatment, including endovascular therapy and gamma knife surgery, has been the first choice in many conditions. However, the overall clinical outcome of microinvasive treatment remains unknown and a prospective trial is needed. This is a prospective, non-randomized, and multicenter observational registry clinical trial to evaluate the safety and efficacy of microinvasive treatment for BAVMs. The study will require up to 400 patients in approximately 12 or more centers in China, followed for 2 years. Main subjects of this study are BAVM patients underwent endovascular therapy and/or gamma knife surgery. The trial will not affect the choice of treatment modality. The primary outcomes are perioperative complications (safety), and postoperative hemorrhage incidence rate and complete occlusion rate (efficacy). Secondary outcomes are elimination of hemorrhage risk factors (coexisting aneurysms and arteriovenous fistula), volume reduction and remission of symptoms. Safety and efficacy of endovascular therapy, gamma knife surgery, and various combination modes of the two modalities will be compared. Operative complications and outcomes at pretreatment, post-treatment, at discharge and at 3 months, 6 months and 2 years follow-up intervals will be analyzed using the modified Rankin Scale (mRS). The most confusion on BAVM treatment is whether to choose interventional therapy or medical therapy, and the choice of interventional therapy modes. This study will provide evidence for evaluating the safety and efficacy of microinvasive treatment in China, to characterize the microinvasive treatment strategy for BAVMs.

  3. Factors That Influence Surgical Margin State in Patients Undergoing Cold Knife Conization - A Single Center Experience.

    PubMed

    Aluloski, Igor; Tanturovski, Mile; Petrusevska, Gordana; Jovanovic, Rubens; Kostadinova-Kunovska, Slavica

    2017-12-01

    To evaluate the factors that influence the surgical margin state in patients undergoing cold knife conization at the University Clinic of Gynecology and Obstetrics in Skopje, Republic of Macedonia Materials and methods: We have retrospectively analyzed the medical records of all patients that underwent a cold knife conization at our Clinic in 2015. We cross-referenced the surgical margin state with the histopathological diagnosis (LSIL, HSIL or micro-invasive/invasive cancer), menopausal status of the patients, number of pregnancies, surgeon experience, operating time and cone depth. The data was analyzed with the Chi square test, Fisher's exact test for categorical data and Student's T test for continuous data and univariate and multivariate logistical regressions were performed. A total of 246 medical records have neen analyzed, out of which 29 (11.79%) patients had LSIL, 194 (78.86%) had HSIL and 23 (9.34%) patients suffered micro-invasive/invasive cervical cancer. The surgical margins were positive in 78 (31.7%) of the patients. The average age of the patients was 41.13 and 35 (14.23%) of the patients were menopausal. The multivariate logistic regression identified preoperative forceps biopsy of micro-invasive SCC, HSIL or higher cone specimen histology and shorter cone depth as independent predictors of surgical margin involvement in patients undergoing cold knife conization. In the current study, we have found no association between the inherent characteristics of the patient and the surgeon and the surgical margin state after a CKC. The most important predictors for positive margins were the severity of the lesion and the cone depth.

  4. Endoscopic submucosal dissection for early esophageal neoplasms using the stag beetle knife.

    PubMed

    Kuwai, Toshio; Yamaguchi, Toshiki; Imagawa, Hiroki; Miura, Ryoichi; Sumida, Yuki; Takasago, Takeshi; Miyasako, Yuki; Nishimura, Tomoyuki; Iio, Sumio; Yamaguchi, Atsushi; Kouno, Hirotaka; Kohno, Hiroshi; Ishaq, Sauid

    2018-04-21

    To determine short- and long-term outcomes of endoscopic submucosal dissection (ESD) using the stag beetle (SB) knife, a scissor-shaped device. Seventy consecutive patients with 96 early esophageal neoplasms, who underwent ESD using a SB knife at Kure Medical Center and Chugoku Cancer Center, Japan, between April 2010 and August 2016, were retrospectively evaluated. Clinicopathological characteristics of lesions and procedural adverse events were assessed. Therapeutic success was evaluated on the basis of en bloc , histologically complete, and curative or non-curative resection rates. Overall and tumor-specific survival, local or distant recurrence, and 3- and 5-year cumulative overall metachronous cancer rates were also assessed. Eligible patients had dysplasia/intraepithelial neoplasia (22%) or early cancers (squamous cell carcinoma, 78%). The median procedural time was 60 min and on average, the lesions measured 24 mm in diameter, yielding 33-mm tissue defects. The en bloc resection rate was 100%, with 95% and 81% of dissections deemed histologically complete and curative, respectively. All procedures were completed without accidental incisions/perforations or delayed bleeding. During follow-up (mean, 35 ± 23 mo), no local recurrences or metastases were observed. The 3- and 5-year survival rates were 83% and 70%, respectively, with corresponding rates of 85% and 75% for curative resections and 74% and 49% for non-curative resections. The 3- and 5-year cumulative rates of metachronous cancer in the patients with curative resections were 14% and 26%, respectively. ESD procedures using the SB knife are feasible, safe, and effective for treating early esophageal neoplasms, yielding favorable short- and long-term outcomes.

  5. Clinical Evaluation of Targeting Accuracy of Gamma Knife Radiosurgery in Trigeminal Neuralgia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Massager, Nicolas; Abeloos, Laurence; Devriendt, Daniel

    2007-12-01

    Purpose: The efficiency of radiosurgery is related to its highly precise targeting. We assessed clinically the targeting accuracy of radiosurgical treatment with the Leksell Gamma Knife for trigeminal neuralgia. We also studied the applied radiation dose within the area of focal contrast enhancement on the trigeminal nerve root following radiosurgery. Methods and Materials: From an initial group of 78 patients with trigeminal neuralgia treated with gamma knife radiosurgery using a 90-Gy dose, we analyzed a subgroup of 65 patients for whom 6-month follow-up MRI showed focal contrast enhancement of the trigeminal nerve. Follow-up MRI was spatially coregistered to the radiosurgicalmore » planning MRI. Target accuracy was assessed from deviation of the coordinates of the intended target compared with the center of enhancement on postoperative MRI. Radiation dose delivered at the borders of contrast enhancement was evaluated. Results: The median deviation of the coordinates between the intended target and the center of contrast enhancement was 0.91 mm in Euclidean space. The radiation doses fitting within the borders of the contrast enhancement of the trigeminal nerve root ranged from 49 to 85 Gy (median value, 77 {+-} 8.7 Gy). Conclusions: The median deviation found in clinical assessment of gamma knife treatment for trigeminal neuralgia is low and compatible with its high rate of efficiency. Focal enhancement of the trigeminal nerve after radiosurgery occurred in 83% of our patients and was not associated with clinical outcome. Focal enhancement borders along the nerve root fit with a median dose of 77 {+-} 8.7 Gy.« less

  6. Rare case of malignant craniopharyngioma reactive to adjunctive stereotactic radiotherapy and chemotherapy; Case report and review.

    PubMed

    Nomura, Shunsunke; Aihara, Yasuo; Amano, Kosaku; Eguchi, Seiichiro; Chiba, Kentaro; Komori, Takashi; Kawamata, Takakazu

    2018-06-19

    Malignant craniopharyngioma or anaplastic craniopharyngioma was first reported in 1987 by Akachi. It has a malignant clinical and histological feature; remarkably rapid progression, atypical pathology like squamous cell carcinoma and poor prognosis. To date seventeen cases of malignant craniopharyngioma have been reported and of these cases, most were of secondary malignant tumor in nature. With respect to traditional benign craniopharyngioma, adjunctive treatment after gross total removal is not necessary, but in the case of malignant types of the tumor, adjunctive treatment is important. This paper presents the first case of malignant craniopharyngioma reactive to adjunctive Gamma knife stereotactic radiosurgery and chemotherapy. Malignant craniopharyngioma is very rare, and we report Gamma knife stereotactic radiosurgery and chemotherapy (Carboplatine and etoposide chemotherapy), as well as Temozolomide chemotherapy were effective and could control progression of the tumor temporarily. Since adjunctive Gamma knife stereotactic radiosurgery and chemotherapy of malignant craniopharyngioma cases affects follow-up strategies, we propose supporting the need to a revision to the WHO classification regarding malignancy evaluation of craniopharyngioma. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Effect of raw materials and hardening process on hardness of manually forged knife

    NASA Astrophysics Data System (ADS)

    Balkhaya, Suwarno

    2017-06-01

    Knives are normally made by forging process either using a machine or traditional method by means of hammering process. This present work was conducted to study the effects of steel raw materials and hardening process on the hardness of manually forged knives. The knife samples were made by traditional hammering (forging) process done by local blacksmith. Afterward, the samples were heat treated with two different hardening procedures, the first was based on the blacksmith procedure and the second was systematically done at the laboratory. The forging was done in the temperature ranged between 900-950°C, while the final temperature ranged between 650-675°C. The results showed that knives made of spring steel and heat treated in simulated condition at the laboratory obtained higher level of hardness, i.e. 62 HRC. In general, knives heat treated by local blacksmith had lower level of hardness that those obtained from simulated condition. Therefore, we concluded that the traditional knife quality in term of hardness can be improved by optimizing the heat treatment schedule.

  8. Long-Term Survival of a Patient with Brainstem and Recurrent Brain Metastasis from Stage IV Nonsmall Cell Lung Cancer Treated with Multiple Gamma Knife Radiosurgeries and Craniotomies: A Case Report and Review of the Literature

    PubMed Central

    Lamm, Andrew F.; Elaimy, Ameer L.; Mackay, Alexander R.; Fairbanks, Robert K.; Demakas, John J.; Cooke, Barton S.; Lee, Christopher M.; Taylor, Blake S.; Lamoreaux, Wayne T.

    2012-01-01

    The prognosis of patients diagnosed with stage IV nonsmall cell lung cancer that have brain and brainstem metastasis is very poor, with less than a third surviving a year past their initial date of diagnosis. We present the rare case of a 57-year-old man who is a long-term survivor of brainstem and recurrent brain metastasis, after aggressive treatment. He is now five and a half years out from diagnosis and continues to live a highly functional life without evidence of disease. Four separate Gamma Knife stereotactic radiosurgeries in conjunction with two craniotomies were utilized since his initial diagnosis to treat recurrent brain metastasis while chemoradiation therapy and thoracic surgery were used to treat his primary disease in the right upper lung. In his situation, Gamma Knife radiosurgery proved to be a valuable, safe, and effective tool for the treatment of multiply recurrent brain metastases within critical normal structures. PMID:23056973

  9. Decision-making in the colposcopy clinic--a critical analysis.

    PubMed

    Bornstein, J; Yaakov, Z; Pascal, B; Faktor, J; Baram, A; Zarfati, D; Abramovici, H

    1999-08-01

    To consider the omission of several diagnostic steps from the management of patients with high-grade squamous intraepithelial lesion (SIL) by analyzing the role of each step on the choice of treatment. Each diagnostic procedure was correlated to the treatment and outcome in 87 women with high-grade SIL. Treatments considered were large loop excision of the transformation zone (LLETZ) cold knife conization, and CO2 laser vaporization. Unsatisfactory colposcopy (P< or =0.01) and positive endocervical curettage (ECC) specimen (P< or =0.01) were essential for choice of treatment. CIN2 diagnoses of the preoperative cervical biopsy were rediagnosed as CIN3 based on the surgical specimen in 57% of the cases. The margins of 33 and 23% of surgical specimens removed by LLETZ or knife conization, respectively, displayed CIN involvement. Forty and 47% of these patients, respectively, later developed recurrent CIN. Omission of colposcopy and ECC could have resulted in sub-optimal treatment in many cases. Excision by LLETZ or knife conization is recommended for cases of CIN2 and CIN3. Follow up is imperative for patients with involvement of the margins.

  10. Basement of Structure, Main Power and Design Parameters of Mechanism of Removing Sections of Mechanized Sets of Knife Plane Installation

    NASA Astrophysics Data System (ADS)

    Sysoev, N. I.; Turuk, Yu V.; Kolesnichenko, I. Y.; Lugantsev, B. B.

    2017-10-01

    The reasons for the failure of the pitch stability of the knife-plane installation due to the action of extreme effort in the plane of the seam from the conveyor side on the mechanism of removing sections of mechanized sets are shown. The technique for determining this effort is presented. The constructions of the adaptive mechanisms of the removing sections of mechanized sets with the basements of catamaran type, in the constrictions of which elastic elements (rods) are used, are considered. The constructions of the mechanism of removing a section of the mechanized set with the basement of catamaran type in which the stock of the hydraulic jack is connected with the band loop through the movable rods intermediate basement with a link are worked out. The intermediate basement unloads the stock of the hydraulic jack of the moving installation from the side curving efforts, caused by the action of lateral forces in the plane of the seam on the conveyor side. It increases the reliability and efficiency of work of the knife plane mechanized complex.

  11. Forensic microradiology: micro-computed tomography (Micro-CT) and analysis of patterned injuries inside of bone.

    PubMed

    Thali, Michael J; Taubenreuther, Ulrike; Karolczak, Marek; Braun, Marcel; Brueschweiler, Walter; Kalender, Willi A; Dirnhofer, Richard

    2003-11-01

    When a knife is stabbed in bone, it leaves an impression in the bone. The characteristics (shape, size, etc.) may indicate the type of tool used to produce the patterned injury in bone. Until now it has been impossible in forensic sciences to document such damage precisely and non-destructively. Micro-computed tomography (Micro-CT) offers an opportunity to analyze patterned injuries of tool marks made in bone. Using high-resolution Micro-CT and computer software, detailed analysis of three-dimensional (3D) architecture has recently become feasible and allows microstructural 3D bone information to be collected. With adequate viewing software, data from 2D slice of an arbitrary plane can be extracted from 3D datasets. Using such software as a "digital virtual knife," the examiner can interactively section and analyze the 3D sample. Analysis of the bone injury revealed that Micro-CT provides an opportunity to correlate a bone injury to an injury-causing instrument. Even broken knife tips can be graphically and non-destructively assigned to a suspect weapon.

  12. WE-A-304-02: Strategies and Technologies for Cranial Radiosurgery Planning: Gamma Knife

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schlesinger, D.

    2015-06-15

    The high fractional doses, stringent requirements for accuracy and precision, and surgical perspective characteristic of intracranial radiosurgery create considerations for treatment planning which are distinct from most other radiotherapy procedures. This session will introduce treatment planning techniques specific to two popular intracranial SRS modalities: Gamma Knife and MLC-based Linac. The basic treatment delivery characteristics of each device will be reviewed with a focus on how those characteristics determine the paradigm used for treatment planning. Basic techniques for treatment planning will be discussed, including considerations such as isodose selection, target and organ-at-risk definition, quality indices, and protection of critical structures. Futuremore » directions for SRS treatment planning will also be discussed. Learning Objectives: Introduce the basic physical principles of intracranial radiosurgery and how they are realized in the treatment planning paradigms for Gamma Knife and Linac radiosurgery. Demonstrate basic treatment planning techniques. Discuss metrics for evaluating SRS treatment plan quality. Discuss recent and future advances in SRS treatment planning. D. Schlesinger receives research support from Elekta, AB.« less

  13. Penetrating brain injury with a metal bar and a knife: Report of two interesting cases.

    PubMed

    Tabibkhooei, Alireza; Taheri, Morteza; Rohani, Sadra; Chanideh, Iran; Rahatlou, Hessam

    2018-04-01

    Introduction Penetrating brain injury (PBI) is uncommon among the civilian population. Here, we report two interesting cases of PBI. Case presentation The first patient was a 20-year-old male who sustained a penetrating head injury with a metal bar during an accident at work. The patient underwent early surgical intervention, and related meningitis was treated with antibiotics. The patient was discharged 45 days later with no deficit. The second patient was a 34-year-old male who was the victim of a violence attack and was admitted to hospital. He was struck by a knife to his right temporal bone. A brain computed tomography scan and magnetic resonance imaging (MRI) demonstrated the tract of the knife within the brain parenchyma. The patient underwent conservative treatment. After several weeks, the patient was discharged in good health. Conclusion Although severe PBI has a poorer prognosis than a blunt brain injury, in treating of these patients, aggressive and timely surgical intervention, proper wide-spectrum antibiotic administration, stringent and diligent care in the intensive-care unit and careful management of the associated complications are mandated.

  14. Positive clinical effects of gamma knife capsulotomy in a patient with deep brain stimulation-refractory Tourette Syndrome and Obsessive Compulsive Disorder.

    PubMed

    Richieri, Raphaëlle; Blackman, Graham; Musil, Richard; Spatola, Giorgio; Cavanna, Andrea E; Lançon, Christophe; Régis, Jean

    2018-04-26

    We report the first case of a patient with severe, intractable Tourette Syndrome with comorbid Obsessive Compulsive disorder, who recovered from both disorders with gamma-knife (GK) stereotactic radiosurgery following deep brain stimulation (DBS). This case highlights the possible role of the internal capsule within the neural circuitries underlying both TS and OCD, and suggests that in cases of treatment-refractory TS and comorbid OCD, bilateral anterior capsulotomy using stereotactic radiosurgery may be a viable treatment option. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Evaluation of Dose Uncertainty to the Target Associated With Real-Time Tracking Intensity-Modulated Radiation Therapy Using the CyberKnife Synchrony System.

    PubMed

    Iwata, Hiromitsu; Inoue, Mitsuhiro; Shiomi, Hiroya; Murai, Taro; Tatewaki, Koshi; Ohta, Seiji; Okawa, Kohei; Yokota, Naoki; Shibamoto, Yuta

    2016-02-01

    We investigated the dose uncertainty caused by errors in real-time tracking intensity-modulated radiation therapy (IMRT) using the CyberKnife Synchrony Respiratory Tracking System (SRTS). Twenty lung tumors that had been treated with non-IMRT real-time tracking using CyberKnife SRTS were used for this study. After validating the tracking error in each case, we did 40 IMRT planning using 8 different collimator sizes for the 20 patients. The collimator size was determined for each planning target volume (PTV); smaller ones were one-half, and larger ones three-quarters, of the PTV diameter. The planned dose was 45 Gy in 4 fractions prescribed at 95% volume border of the PTV. Thereafter, the tracking error in each case was substituted into calculation software developed in house and randomly added in the setting of each beam. The IMRT planning incorporating tracking errors was simulated 1000 times, and various dose data on the clinical target volume (CTV) were compared with the original data. The same simulation was carried out by changing the fraction number from 1 to 6 in each IMRT plan. Finally, a total of 240 000 plans were analyzed. With 4 fractions, the change in the CTV maximum and minimum doses was within 3.0% (median) for each collimator. The change in D99 and D95 was within 2.0%. With decreases in the fraction number, the CTV coverage rate and the minimum dose decreased and varied greatly. The accuracy of real-time tracking IMRT delivered in 4 fractions using CyberKnife SRTS was considered to be clinically acceptable. © The Author(s) 2014.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brezovich, I; Wu, X; Popple, R

    Purpose: To test spatial and dosimetric accuracy of small cranial target irradiation based on 1.5 T MRI scans using static arcs with MLC-defined fields Methods: A plastic (PMMA) phantom simulating a small brain lesion was mounted on a GammaKnife headframe equipped with MRI localizer. The lesion was a 3 mm long, 3.175 mm diameter cylindrical cavity filled with MRI contrast. Radiochromic film passing through the cavity was marked with pin pricks at the cavity center. The cavity was contoured on an MRI image and fused with CT to simulate treatment of a lesion not visible on CT. The transfer ofmore » the target to CT involved registering the MRI contrast cannels of the localizer that were visible on both modalities. Treatments were planned to deliver 800 cGy to the cavity center using multiple static arcs with 5.0×2.4 mm MLC-defined fields. The phantom was aligned on a STx accelerator by registering the conebeam CT with the planning CT. Films from coronal and sagittal planes were scanned and evaluated using ImageJ software Results: Geographic errors in treatment based on 1.5 T scans agreed within 0.33, −0.27 and 1.21 mm in the vertical, lateral and longitudinal dimensions, respectively. The doses delivered to the cavity center were 7.2% higher than planned. The dose distributions were similar to those of a GammaKnife. Conclusion: Radiation can be delivered with an accelerator at mm accuracy to small cranial targets based on 1.5 MRI scans fused to CTs using a standard GammaKnife headframe and MRI localizer. MLC-defined static arcs produce isodose lines very similar to the GammaKnife.« less

  17. Expansion of Mandibular Knife-Edge Ridge and Simultaneous Implant Placement to Retain Overdentures: One-Year Clinical and Radiographic Results of a Prospective Study.

    PubMed

    ELsyad, Moustafa Abdou; Hammouda, Nelly Ibrahim

    2017-02-01

    The aim of this study was to evaluate and compare the clinical and radiographic outcomes of two implants placed in expanded mandibular knife-edge ridge and implants placed in unexpanded ridges to retain overdentures. Fifteen completely edentulous patients with knife-edge ridges at canine areas of the mandible received two implants using the ridge expansion technique (study group, SG). Expansion was performed using piezoelectric corticotomy, and self-threading expanders. The control group (CG) comprised patients who received two-implant at canine areas without ridge expansion but were all case matched to SG and served as historical cohort. In both groups, mandibular overdentures were connected to the implants with Locator attachments 3 months after implant placement. Clinical (Plaque index; PI, Gingival index; GI, Probing depth; PD, and implant stability; ISQ) and radiographic (Vertical bone loss; VBL) parameters were recorded at time of overdenture insertion (base line, T0), 6 months (T6), and 12 months (T12) after insertion. The cumulative success rates were 100% and 96.4% for CG and SG, respectively, without significant difference between groups. All tested parameters increased significantly with advance of time in both groups. There was no significant difference in PI, GI, PD, and ISQ between groups. However, SG recorded significant higher VBL than CG at T6 and T12. Expansion of mandibular knife edge ridge and simultaneous placement of implants to retain overdentures is associated with clinic and radiographic outcomes comparable to implants placed in unexpanded ridges after 1 year. However, long term randomized controlled trials with sufficient sample size are still needed to ensure the findings of the present study. © 2016 Wiley Periodicals, Inc.

  18. A comprehensive statistical investigation of schlieren image velocimetry (SIV) using high-velocity helium jet

    NASA Astrophysics Data System (ADS)

    Biswas, Sayan; Qiao, Li

    2017-03-01

    A detailed statistical assessment of seedless velocity measurement using Schlieren Image Velocimetry (SIV) was explored using open source Robust Phase Correlation (RPC) algorithm. A well-known flow field, an axisymmetric turbulent helium jet, was analyzed near and intermediate region (0≤ x/d≤ 20) for two different Reynolds numbers, Re d = 11,000 and Re d = 22,000 using schlieren with horizontal knife-edge, schlieren with vertical knife-edge and shadowgraph technique, and the resulted velocity fields from SIV techniques were compared to traditional Particle Image Velocimetry (PIV) measurements. A novel, inexpensive, easy to setup two-camera SIV technique had been demonstrated to measure high-velocity turbulent jet, with jet exit velocities 304 m/s (Mach = 0.3) and 611 m/s (Mach = 0.6), respectively. Several image restoration and enhancement techniques were tested to improve signal to noise ratio (SNR) in schlieren and shadowgraph images. Processing and post-processing parameters for SIV techniques were examined in detail. A quantitative comparison between self-seeded SIV techniques and traditional PIV had been made using correlation statistics. While the resulted flow field from schlieren with horizontal knife-edge and shadowgraph showed excellent agreement with PIV measurements, schlieren with vertical knife-edge performed poorly. The performance of spatial cross-correlations at different jet locations using SIV techniques and PIV was evaluated. Turbulence quantities like turbulence intensity, mean velocity fields, Reynolds shear stress influenced spatial correlations and correlation plane SNR heavily. Several performance metrics such as primary peak ratio (PPR), peak to correlation energy (PCE), the probability distribution of signal and noise were used to compare capability and potential of different SIV techniques.

  19. The safety and efficacy of gamma knife surgery in management of glomus jugulare tumor

    PubMed Central

    2010-01-01

    Background Glomus jugulare is a slowly growing, locally destructive tumor located in the skull base with difficult surgical access. The operative approach is, complicated by the fact that lesions may be both intra and extradural with engulfment of critical neurovascular structures. The tumor is frequently highly vascular, thus tumor resection entails a great deal of morbidity and not infrequent mortality. At timeslarge residual tumors are left behind. To decrease the morbidity associated with surgical resection of glomus jugulare, gamma knife surgery (GKS) was performed as an alternative in 13 patients to evaluate its safety and efficacy. Methods A retrospective review of 13 residual or unresectable glomus jagulare treated with GKS between 2004 and 2008.. Of these, 11 patients underwent GKS as the primary management and one case each was treated for postoperative residual disease and postembolization. The radiosurgical dose to the tumor margin ranged between 12-15 Gy. Results Post- gamma knife surgery and during the follow-up period twelve patients demonstrated neurological stability while clinical improvement was achieved in 5 patients. One case developed transient partial 7th nerve palsy that responded to medical treatment. In all patients radiographic MRI follow-up was obtained, the tumor size decreased in two cases and remained stable (local tumor control) in eleven patients. Conclusions Gamma knife surgery provids tumor control with a lowering of risk of developing a new cranial nerve injury in early follow-up period. This procedure can be safely used as a primary management tool in patients with glomus jugulare tumors, or in patients with recurrent tumors in this location. If long-term results with GKS are equally effective it will emerge as a good alternative to surgical resection. PMID:20819207

  20. Endoscopic needle-knife treatment for symptomatic esophageal Zenker's diverticulum: A meta-analysis and systematic review.

    PubMed

    Li, Lian Yong; Yang, Yong Tao; Qu, Chang Min; Liang, Shu Wen; Zhong, Chang Qing; Wang, Xiao Ying; Chen, Yan; Spandorfer, Robert M; Christofaro, Sarah; Cai, Qiang

    2018-04-01

    The aim of this study was to assess the efficacy and safety following endoscopic management of Zenker's diverticulum (ZD) using a needle-knife technique. A systematic search of PubMed, Embase and Cochrane library databases was performed. All original studies reporting efficacy and safety of needle-knife technique for treatment of ZD were included. Pooled event rates across studies were expressed with summative statistics. Main outcomes, such as rates of immediate symptomatic response (ISR), adverse events and recurrence, were extracted, pooled and analyzed. Heterogeneity among studies was assessed using the R statistic. The random effects model was used and results were expressed with forest plots and summative statistics. Thirteen studies included 589 patients were enrolled. Pooled event rates for ISR, overall complication, bleeding and perforation were 88% (95% confidence interval [CI] 79-94%), 13% (95% CI 8-22%), 5% (95% CI 3-10%) and 7% (95% CI 4-12%), respectively. The pooled data demonstrated an overall recurrence rate of 14% (95% CI 9-21%). Diverticulum size of at least 4 cm and less than 4 cm demonstrated pooled adverse event rates of 17% (95% CI 10-27%) and 7% (95% CI 2-18%), respectively. When using diverticuloscope as an accessory, pooled ISR and adverse events rates were 84% (95% CI 58-95%) and 10% (95% CI 3-26%), respectively. Flexible endoscopic procedures using needle-knife offers a relatively safe and effective treatment of symptomatic ZD, especially for ZD of <4 cm in diameter. © 2018 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  1. Endoscopic submucosal tunnel dissection of upper gastrointestinal submucosal tumors: A comparative study of hook knife vs hybrid knife.

    PubMed

    Zhou, Jie-Qiong; Tang, Xiao-Wei; Ren, Yu-Tang; Wei, Zheng-Jie; Huang, Si-Lin; Gao, Qiao-Ping; Zhang, Xiao-Feng; Yang, Jian-Feng; Gong, Wei; Jiang, Bo

    2017-03-14

    To compare the efficacy and safety of a hook knife (HO) with a hybrid knife (HK) during endoscopic submucosal tunnel dissection (ESTD) procedure. Between August 2012 and December 2015, the ESTD procedure was performed for 83 upper GI submucosal lesions, which originated from the muscularis propria layer identified by upper endoscopy and endoscopic ultrasonography. Of these, 34 lesions were treated by a HO, whereas 49 lesions were treated by a HK. Data regarding age, gender, presenting symptoms, tumor location and size, procedure time, complications, en bloc resection rate and others were analyzed and compared between the two groups. There were no significant differences in the age, gender, presenting symptoms and tumor location between the two groups. ESTD was successfully completed in all the patients, and no case was converted to laparoscopy. The mean procedure time was significantly shorter in the HK group than in the HO group (41.3 ± 20.3 min vs 57.2 ± 28.0 min, P = 0.004). The mean frequency of device exchange was 1.4 ± 0.6 in the HK group and significantly less than 3.3 ± 0.6 in the HO group ( P < 0.001). The differences in tumor size and histopathological diagnoses were not significant between the two groups ( P = 0.813, P = 0.363, respectively). Both groups had an equal en bloc resection rate and complete resection rate. Additionally, the complication rate was similar between the two groups ( P = 0.901). During the follow-up, no recurrence occurred in either group. We demonstrate for the first time that HO and HK do not differ in efficacy or safety, but HK reduces the frequency of device exchange and procedure time.

  2. SU-F-SPS-10: The Dosimetric Comparison of GammaKnife and Cyberknife Treatment Plans for Brain SRS Treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanli, E; Mabhouti, H; Cebe, M

    Purpose: Brain stereotactic radiosurgery (SRS) involves the use of precisely directed, single session radiation to create a desired radiobiologic response within the brain target with acceptable minimal effects on surrounding structures or tissues. In this study, the dosimetric comparison of GammaKnife perfection and Cyberknife M6 treatment plans were made. Methods: Treatment plannings were done for GammaKnife perfection unit using Gammaplan treatment planning system (TPS) on the CT scan of head and neck randophantom simulating the treatment of sterotactic treatments for one brain metastasis. The dose distribution were calculated using TMR 10 algorithm. The treatment planning for the same target weremore » also done for Cyberknife M6 machine using Multiplan (TPS) with Monte Carlo algorithm. Using the same film batch, the net OD to dose calibration curve was obtained using both machine by delivering 0- 800 cGy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. Dose distribution were measured using EBT3 film dosimeter. The measured and calculated doses were compared. Results: The dose distribution in the target and 2 cm beyond the target edge were calculated on TPSs and measured using EBT3 film. For cyberknife treatment plans, the gamma analysis passing rates between measured and calculated dose distributions were 99.2% and 96.7% for target and peripheral region of target respectively. For gammaknife treatment plans, the gamma analysis passing rates were 98.9% and 93.2% for target and peripheral region of target respectively. Conclusion: The study shows that dosimetrically comparable plans are achievable with Cyberknife and GammaKnife. Although TMR 10 algorithm predicts the target dose.« less

  3. Holmium laser vs. conventional (cold knife) direct visual internal urethrotomy for short-segment bulbar urethral stricture: Outcome analysis.

    PubMed

    Jhanwar, Ankur; Kumar, Manoj; Sankhwar, Satya Narayan; Prakash, Gaurav

    2016-01-01

    Our goal was to analyze the outcome between holmium laser and cold knife direct visual internal urethrotomy (DVIU) for short-segment bulbar urethral stricture. We conducted a prospective study comprised of 112 male patients seen from June 2013 to December 2014. Inclusion criterion was short-segment bulbar urethral stricture (≤1.5cm). Exclusion criteria were prior intervention/urethroplasty, pan-anterior urethral strictures, posterior stenosis, urinary tract infection, and those who lost to followup. Patients were divided into two groups; Group A (n=58) included cold knife DVIU and group B (n=54) included holmium laser endourethrotomy patients. Patient followup included uroflowmetry at postoperative Day 3, as well as at three months and six months. Baseline demographics were comparable in both groups. A total of 107 patients met the inclusion criteria and five patients were excluded due to inadequate followup. Mean stricture length was 1.31 ± 0.252 cm (p=0.53) and 1.34 ± 0.251 cm in Groups A and B, respectively. Mean operating time in Group A was 16.3 ± 1.78 min and in Group B was 20.96 ± 2.23 min (p=0.0001). Five patients in Group A had bleeding after the procedure that was managed conservatively by applying perineal compression. Three patients in Group B had fluid extravasation postoperatively. Qmax (ml/s) was found to be statistically insignificant between the two groups at all followups. Both holmium laser and cold knife urethrotomy are safe and equally effective in treating short-segment bulbar urethral strictures in terms of outcome and complication rate. However, holmium laser requires more expertise and is a costly alternative.

  4. SU-E-T-453: Optimization of Dose Gradient for Gamma Knife Radiosurgery.

    PubMed

    Sheth, N; Chen, Y; Yang, J

    2012-06-01

    The goals of stereotactic radiosurgery (SRS) are the ablation of target tissue and sparing of critical normal tissue. We develop tools to aid in the selection of collimation and prescription (Rx) isodose line to optimize the dose gradient for single isocenter intracranial stereotactic radiosurgery (SRS) with GammaKnife 4C utilizing the updated physics data in GammaPlan v10.1. Single isocenter intracranial SRS plans were created to treat the center of a solid water anthropomorphism head phantom for each GammaKnife collimator (4 mm, 8 mm, 14 mm, and 18 mm). The dose gradient, defined as the difference of effective radii of spheres equal to half and full Rx volumes, and Rx treatment volume was analyzed for isodoses from 99% to 20% of Rx. The dosimetric data on Rx volume and dose gradient vs. Rx isodose for each collimator was compiled into an easy to read nomogram as well as plotted graphically. The 4, 8, 14, and 18 mm collimators have the sharpest dose gradient at the 64%, 70%, 76%, and 77% Rx isodose lines, respectively. This corresponds to treating 4.77 mm, 8.86 mm, 14.78 mm, and 18.77 mm diameter targets with dose gradients radii of 1.06 mm, 1.63 mm, 2.54 mm, and 3.17 mm, respectively. We analyzed the dosimetric data for the most recent version of GammaPlan treatment planning software to develop tools that when applied clinically will aid in the selection of a collimator and Rx isodose line for optimal dose gradient and target coverage for single isocenter intracranial SRS with GammaKnife 4C. © 2012 American Association of Physicists in Medicine.

  5. Implementation of Monte Carlo Dose calculation for CyberKnife treatment planning

    NASA Astrophysics Data System (ADS)

    Ma, C.-M.; Li, J. S.; Deng, J.; Fan, J.

    2008-02-01

    Accurate dose calculation is essential to advanced stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) especially for treatment planning involving heterogeneous patient anatomy. This paper describes the implementation of a fast Monte Carlo dose calculation algorithm in SRS/SRT treatment planning for the CyberKnife® SRS/SRT system. A superposition Monte Carlo algorithm is developed for this application. Photon mean free paths and interaction types for different materials and energies as well as the tracks of secondary electrons are pre-simulated using the MCSIM system. Photon interaction forcing and splitting are applied to the source photons in the patient calculation and the pre-simulated electron tracks are repeated with proper corrections based on the tissue density and electron stopping powers. Electron energy is deposited along the tracks and accumulated in the simulation geometry. Scattered and bremsstrahlung photons are transported, after applying the Russian roulette technique, in the same way as the primary photons. Dose calculations are compared with full Monte Carlo simulations performed using EGS4/MCSIM and the CyberKnife treatment planning system (TPS) for lung, head & neck and liver treatments. Comparisons with full Monte Carlo simulations show excellent agreement (within 0.5%). More than 10% differences in the target dose are found between Monte Carlo simulations and the CyberKnife TPS for SRS/SRT lung treatment while negligible differences are shown in head and neck and liver for the cases investigated. The calculation time using our superposition Monte Carlo algorithm is reduced up to 62 times (46 times on average for 10 typical clinical cases) compared to full Monte Carlo simulations. SRS/SRT dose distributions calculated by simple dose algorithms may be significantly overestimated for small lung target volumes, which can be improved by accurate Monte Carlo dose calculations.

  6. GammaKnife surgery: safety and the identity of users.

    PubMed

    Dinka, David; Nyce, James M; Timpka, Toomas

    2005-01-01

    In this study we investigated safety-related usability issues of an advanced medical technology, a radiosurgery system. We were interested in which criteria are important for users when a system's usability and safety is to be improved. The data collection was based on interviews and observations at three different sites where the Leksell GammaKnife is used. The analysis was qualitative. The main finding was that the user's identity or professional background has a significant impact both on how he or she views his or her role in the clinical setting, and on how he or she defines what improvements are necessary and general safety issues. In fact, the opinion even of users experienced in safety-related problems was highly influenced by how they related to the technology and its development. None of the users actually considered Leksell GammaKnife as lacking in safety, instead, their assessment was directed towards potential future system improvements. Our findings suggest that the importance of user identity or professional background cannot be neglected during the development of advanced technology. They also suggest that the user feedback should always be related to user background and identity in order to understand how important different issues are for particular users.

  7. A simplified model of the source channel of the Leksell GammaKnife tested with PENELOPE.

    PubMed

    Al-Dweri, Feras M O; Lallena, Antonio M; Vilches, Manuel

    2004-06-21

    Monte Carlo simulations using the code PENELOPE have been performed to test a simplified model of the source channel geometry of the Leksell GammaKnife. The characteristics of the radiation passing through the treatment helmets are analysed in detail. We have found that only primary particles emitted from the source with polar angles smaller than 3 degrees with respect to the beam axis are relevant for the dosimetry of the Gamma Knife. The photon trajectories reaching the output helmet collimators at (x, v, z = 236 mm) show strong correlations between rho = (x2 + y2)(1/2) and their polar angle theta, on one side, and between tan(-1)(y/x) and their azimuthal angle phi, on the other. This enables us to propose a simplified model which treats the full source channel as a mathematical collimator. This simplified model produces doses in good agreement with those found for the full geometry. In the region of maximal dose, the relative differences between both calculations are within 3%, for the 18 and 14 mm helmets, and 10%, for the 8 and 4 mm ones. Besides, the simplified model permits a strong reduction (larger than a factor 15) in the computational time.

  8. Endoscopic submucosal dissection for locally recurrent colorectal lesions after previous endoscopic mucosal resection.

    PubMed

    Zhou, Pinghong; Yao, Liqing; Qin, Xinyu; Xu, Meidong; Zhong, Yunshi; Chen, Weifeng

    2009-02-01

    The objective of this study was to determine the efficacy and safety of endoscopic submucosal dissection for locally recurrent colorectal cancer after previous endoscopic mucosal resection. A total of 16 patients with locally recurrent colorectal lesions were enrolled. A needle knife, an insulated-tip knife and a hook knife were used to resect the lesion along the submucosa. The rate of the curative resection, procedure time, and incidence of complications were evaluated. Of 16 lesions, 15 were completely resected with endoscopic submucosal dissection, yielding an en bloc resection rate of 93.8 percent. Histologic examination confirmed that lateral and basal margins were cancer-free in 14 patients (87.5 percent). The average procedure time was 87.2 +/- 60.7 minutes. None of the patients had immediate or delayed bleeding during or after endoscopic submucosal dissection. Perforation in one patient (6.3 percent) was the only complication and was managed conservatively. The mean follow-up period was 15.5 +/- 6.8 months; none of the patients experienced lesion residue or recurrence. Endoscopic submucosal dissection appears to be effective for locally recurrent colorectal cancer after previous endoscopic mucosal resection, making it possible to resect whole lesions and provide precise histologic information.

  9. MCNP-based computational model for the Leksell gamma knife.

    PubMed

    Trnka, Jiri; Novotny, Josef; Kluson, Jaroslav

    2007-01-01

    We have focused on the usage of MCNP code for calculation of Gamma Knife radiation field parameters with a homogenous polystyrene phantom. We have investigated several parameters of the Leksell Gamma Knife radiation field and compared the results with other studies based on EGS4 and PENELOPE code as well as the Leksell Gamma Knife treatment planning system Leksell GammaPlan (LGP). The current model describes all 201 radiation beams together and simulates all the sources in the same time. Within each beam, it considers the technical construction of the source, the source holder, collimator system, the spherical phantom, and surrounding material. We have calculated output factors for various sizes of scoring volumes, relative dose distributions along basic planes including linear dose profiles, integral doses in various volumes, and differential dose volume histograms. All the parameters have been calculated for each collimator size and for the isocentric configuration of the phantom. We have found the calculated output factors to be in agreement with other authors' works except the case of 4 mm collimator size, where averaging over the scoring volume and statistical uncertainties strongly influences the calculated results. In general, all the results are dependent on the choice of the scoring volume. The calculated linear dose profiles and relative dose distributions also match independent studies and the Leksell GammaPlan, but care must be taken about the fluctuations within the plateau, which can influence the normalization, and accuracy in determining the isocenter position, which is important for comparing different dose profiles. The calculated differential dose volume histograms and integral doses have been compared with data provided by the Leksell GammaPlan. The dose volume histograms are in good agreement as well as integral doses calculated in small calculation matrix volumes. However, deviations in integral doses up to 50% can be observed for large volumes such as for the total skull volume. The differences observed in treatment of scattered radiation between the MC method and the LGP may be important in this case. We have also studied the influence of differential direction sampling of primary photons and have found that, due to the anisotropic sampling, doses around the isocenter deviate from each other by up to 6%. With caution about the details of the calculation settings, it is possible to employ the MCNP Monte Carlo code for independent verification of the Leksell Gamma Knife radiation field properties.

  10. Cold-knife conisation and large loop excision of transformation zone significantly increase the risk for spontaneous preterm birth: a population-based cohort study.

    PubMed

    Jančar, Nina; Mihevc Ponikvar, Barbara; Tomšič, Sonja

    2016-08-01

    Our aim was to explore the association between cold-knife conisation and large loop excision of transformation zone (LLETZ) with spontaneous preterm birth in a large 10-year national sample. We wanted to explore further the association of these procedures with preterm birth according to gestation. We conducted a population based retrospective cohort study, using data from national Medical Birth Registry. The study population consisted of all women giving birth to singletons in the period 2003-2012 in Slovenia, excluding all induced labors and elective cesarean sections before 37 weeks of gestation (N=192730). We compared the prevalence of spontaneous preterm births (before 28 weeks, before 32 weeks, before 34 weeks and before 37 weeks of gestation) in women with cold-knife conisation or LLETZ compared to women without history of conisation, calculating odds ratios (OR), adjusted for potential confounders. Chi-square test was used for descriptive analysis. Logistic regression analyses were performed to estimate crude odds ratio (OR) and adjusted odds ratio (aOR) and their 95% confidence intervals (95% CI) with two-sided probability (p) values. A total of 8420 (4.4%) women had a preterm birth before 37 weeks of gestation, 2250 (1.2%) before 34 weeks of gestation, 1333 (0.7%) before 32 weeks of gestation and 603 (0.3%) before 28 weeks of gestation. A total of 4580 (2.4%) women had some type of conisation in their medical history: 2083 (1.1%) had cold-knife conisation and 2498 (1.3%) had LLETZ. In women with history of cold-knife conisation, the adjusted OR for preterm birth before 37 weeks of gestation was 3.13 (95% CI; 2.74-3.57) and for preterm birth before 28 weeks of gestation 5.96 (95% CI; 4.3-8.3). In women with history of LLETZ, the adjusted OR was 1.95 (95% CI; 1.68-2.25) and 2.88 (95% CI; 1.87-4.43), respectively. Women with cervical excision procedure of any kind have significantly increased odds for preterm birth, especially for preterm birth before 28 weeks and before 32 weeks of gestation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Reference respiratory waveforms by minimum jerk model analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anetai, Yusuke, E-mail: anetai@radonc.med.osaka-u.ac.jp; Sumida, Iori; Takahashi, Yutaka

    Purpose: CyberKnife{sup ®} robotic surgery system has the ability to deliver radiation to a tumor subject to respiratory movements using Synchrony{sup ®} mode with less than 2 mm tracking accuracy. However, rapid and rough motion tracking causes mechanical tracking errors and puts mechanical stress on the robotic joint, leading to unexpected radiation delivery errors. During clinical treatment, patient respiratory motions are much more complicated, suggesting the need for patient-specific modeling of respiratory motion. The purpose of this study was to propose a novel method that provides a reference respiratory wave to enable smooth tracking for each patient. Methods: The minimummore » jerk model, which mathematically derives smoothness by means of jerk, or the third derivative of position and the derivative of acceleration with respect to time that is proportional to the time rate of force changed was introduced to model a patient-specific respiratory motion wave to provide smooth motion tracking using CyberKnife{sup ®}. To verify that patient-specific minimum jerk respiratory waves were being tracked smoothly by Synchrony{sup ®} mode, a tracking laser projection from CyberKnife{sup ®} was optically analyzed every 0.1 s using a webcam and a calibrated grid on a motion phantom whose motion was in accordance with three pattern waves (cosine, typical free-breathing, and minimum jerk theoretical wave models) for the clinically relevant superior–inferior directions from six volunteers assessed on the same node of the same isocentric plan. Results: Tracking discrepancy from the center of the grid to the beam projection was evaluated. The minimum jerk theoretical wave reduced the maximum-peak amplitude of radial tracking discrepancy compared with that of the waveforms modeled by cosine and typical free-breathing model by 22% and 35%, respectively, and provided smooth tracking for radial direction. Motion tracking constancy as indicated by radial tracking discrepancy affected by respiratory phase was improved in the minimum jerk theoretical model by 7.0% and 13% compared with that of the waveforms modeled by cosine and free-breathing model, respectively. Conclusions: The minimum jerk theoretical respiratory wave can achieve smooth tracking by CyberKnife{sup ®} and may provide patient-specific respiratory modeling, which may be useful for respiratory training and coaching, as well as quality assurance of the mechanical CyberKnife{sup ®} robotic trajectory.« less

  12. Characteristics of a thick film ethanol gas sensor made of mechanically treated LaFeO3 powder

    NASA Astrophysics Data System (ADS)

    Suhendi, Endi; Witra, Hasanah, Lilik; Syarif, Dani Gustaman

    2017-05-01

    In this work, fabrication of LaFeO3 thick film ceramics for ethanol gas sensor made of mechanically treated (milling) powder was studied. The thick films were fabricated using screen printing technique from LaFeO3 powder treated by HEM (High Energy Milling). The films were baked at 800°C for one hour and analyzed using XRD and SEM. Sensitivity of the films was studied by measuring resistance of them at various temperatures in a chamber containing air with and without ethanol gas. Data of XRD showed that the thick film crystalizes in orthorombic structure with space group of Pn*a. SEM data showed that the films consisted of small grains with grain size of about 225 nm. According to the electrical data, the LaFeO3 thick films that produced in this work could be applied as ethanol gas with operating temperature of about 275°C.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Haksoo; Welford, Scott; Fabien, Jeffrey

    Purpose: Establish and validate a process of accurately irradiating small animals using the CyberKnife G4 System (version 8.5) with treatment plans designed to irradiate a hemisphere of a mouse brain based on microCT scanner images. Methods: These experiments consisted of four parts: (1) building a mouse phantom for intensity modulated radiotherapy (IMRT) quality assurance (QA), (2) proving usability of a microCT for treatment planning, (3) fabricating a small animal positioning system for use with the CyberKnife's image guided radiotherapy (IGRT) system, and (4)in vivo verification of targeting accuracy. A set of solid water mouse phantoms was designed and fabricated, withmore » radiochromic films (RCF) positioned in selected planes to measure delivered doses. After down-sampling for treatment planning compatibility, a CT image set of a phantom was imported into the CyberKnife treatment planning system—MultiPlan (ver. 3.5.2). A 0.5 cm diameter sphere was contoured within the phantom to represent a hemispherical section of a mouse brain. A nude mouse was scanned in an alpha cradle using a microCT scanner (cone-beam, 157 × 149 pixels slices, 0.2 mm longitudinal slice thickness). Based on the results of our positional accuracy study, a planning treatment volume (PTV) was created. A stereotactic body mold of the mouse was “printed” using a 3D printer laying UV curable acrylic plastic. Printer instructions were based on exported contours of the mouse's skin. Positional reproducibility in the mold was checked by measuring ten CT scans. To verify accurate dose delivery in vivo, six mice were irradiated in the mold with a 4 mm target contour and a 2 mm PTV margin to 3 Gy and sacrificed within 20 min to avoid DNA repair. The brain was sliced and stained for analysis. Results: For the IMRT QA using a set of phantoms, the planned dose (6 Gy to the calculation point) was compared to the delivered dose measured via film and analyzed using Gamma analysis (3% and 3 mm). A passing rate of 99% was measured in areas of above 40% of the prescription dose. The final inverse treatment plan was comprised of 43 beams ranging from 5 to 12.5 mm in diameter (2.5 mm size increments are available up to 15 mm in diameter collimation). Using the Xsight Spine Tracking module, the CyberKnife system could not reliably identify and track the tiny mouse spine; however, the CyberKnife system could identify and track the fiducial markers on the 3D mold.In vivo positional accuracy analysis using the 3D mold generated a mean error of 1.41 mm ± 0.73 mm when fiducial markers were used for position tracking. Analysis of the dissected brain confirmed the ability to target the correct brain volume. Conclusions: With the use of a stereotactic body mold with fiducial markers, microCT imaging, and resolution down-sampling, the CyberKnife system can successfully perform small-animal radiotherapy studies.« less

  14. Cryo-comminution of plastic waste.

    PubMed

    Gente, Vincenzo; La Marca, Floriana; Lucci, Federica; Massacci, Paolo; Pani, Eleonora

    2004-01-01

    Recycling of plastics is a big issue in terms of environmental sustainability and of waste management. The development of proper technologies for plastic recycling is recognised as a priority. To achieve this aim, the technologies applied in mineral processing can be adapted to recycling systems. In particular, the improvement of comminution technologies is one of the main actions to improve the quality of recycled plastics. The aim of this work is to point out suitable comminution processes for different types of plastic waste. Laboratory comminution tests have been carried out under different conditions of temperature and sample pre-conditioning adopting as refrigerant agents CO2 and liquid nitrogen. The temperature has been monitored by thermocouples placed in the milling chamber. Also different internal mill screens have been adopted. A proper procedure has been set up in order to obtain a selective comminution and a size reduction suitable for further separation treatment. Tests have been performed on plastics coming from medical plastic waste and from a plant for spent lead batteries recycling. Results coming from different mill devices have been compared taking into consideration different indexes for representative size distributions. The results of the performed tests show as cryo-comminution improves the effectiveness of size reduction of plastics, promotes liberation of constituents and increases specific surface size of comminuted particles in comparison to a comminution process carried out at room temperature. Copyright 2004 Elsevier Ltd.

  15. Stereotactic radiosurgery - discharge

    MedlinePlus

    Gamma knife - discharge; Cyberknife - discharge; Stereotactic radiotherapy - discharge; Fractionated stereotactic radiotherapy - discharge; Cyclotrons - discharge; Linear accelerator - discharge; Lineacs - discharge; Proton beam radiosurgery - discharge

  16. Spinal cord injuries due to close combat weapons.

    PubMed

    Fares, Youssef H; Fares, Jawad Y; Gebeily, Souheil E; Khazim, Rabi M

    2013-10-01

    A 17-year-old patient was aggressively attacked and stabbed in the dorsal region of his back by a knife. He was admitted to the emergency room of the Hammoud Hospital University Medical Center, Saida, Lebanon lying in the prone position. The neurological examination revealed that the stabbing object was fixed at the dorsal spine level at the T-7 level, where it was inserted inside the vertebral body. Luckily, the blade of the knife was parallel to the nervous tracts of the spinal cord; thus, he showed no neurological deficits. This case provides an overview of how neurosurgical principles can be applied to trauma patients with spine injuries due to close combat weapons.

  17. Time-dependent spatial intensity profiles of near-infrared idler pulses from nanosecond optical parametric oscillators

    NASA Astrophysics Data System (ADS)

    Olafsen, L. J.; Olafsen, J. S.; Eaves, I. K.

    2018-06-01

    We report on an experimental investigation of the time-dependent spatial intensity distribution of near-infrared idler pulses from an optical parametric oscillator measured using an infrared (IR) camera, in contrast to beam profiles obtained using traditional knife-edge techniques. Comparisons show the information gained by utilizing the thermal camera provides more detail than the spatially- or time-averaged measurements from a knife-edge profile. Synchronization, averaging, and thresholding techniques are applied to enhance the images acquired. The additional information obtained can improve the process by which semiconductor devices and other IR lasers are characterized for their beam quality and output response and thereby result in IR devices with higher performance.

  18. [Thinking of therapeutic mechanism of small knife needle in treating closed myofascitis].

    PubMed

    Zhao, Yong; Fang, Wei; Qin, Wei-kai

    2014-09-01

    The authors investigated and discussed therapeutic mechanism of small knife needle in treating closed myofascitis on the basis of pathomechanism of modern medicine and acupuncture theory of TCM among numbers of clinical cases and experimental data. Therapeutic mechanism lies in 6 aspects: (1) Relieve the energy crisis of tenderness point on muscular fasciae; (2) Affect nervous system and reduce induction of harmful stimulating signal; (3) Inhibit aseptic inflammatory reaction on muscular fasciae; (4) Regulate dynamic equilibrium of soft tissue by cutting scar and releasing the conglutination; (5) Increase patients' regional threshold of feeling; (6) Reduce tension and pressure of soft tissue of tenderness point so as to relieve extrusion of nervus cutaneous.

  19. Apparatus and method for measuring critical current properties of a coated conductor

    DOEpatents

    Mueller, Fred M [Los Alamos, NM; Haenisch, Jens [Dresden, DE

    2012-07-24

    The transverse critical-current uniformity in a superconducting tape was determined using a magnetic knife apparatus. A critical current I.sub.c distribution and transverse critical current density J.sub.c distribution in YBCO coated conductors was measured nondestructively with high resolution using a magnetic knife apparatus. The method utilizes the strong depression of J.sub.c in applied magnetic fields. A narrow region of low, including zero, magnetic field in a surrounding higher field is moved transversely across a sample of coated conductor. This reveals the critical current density distribution. A Fourier series inversion process was used to determine the transverse J.sub.c distribution in the sample.

  20. Vacuum structure and string tension in Yang-Mills dimeron ensembles

    NASA Astrophysics Data System (ADS)

    Zimmermann, Falk; Forkel, Hilmar; Müller-Preußker, Michael

    2012-11-01

    We numerically simulate ensembles of SU(2) Yang-Mills dimeron solutions with a statistical weight determined by the classical action and perform a comprehensive analysis of their properties as a function of the bare coupling. In particular, we examine the extent to which these ensembles and their classical gauge interactions capture topological and confinement properties of the Yang-Mills vacuum. This also allows us to put the classic picture of meron-induced quark confinement, with the confinement-deconfinement transition triggered by dimeron dissociation, to stringent tests. In the first part of our analysis we study spacial, topological-charge and color correlations at the level of both the dimerons and their meron constituents. At small to moderate couplings, the dependence of the interactions between the dimerons on their relative color orientations is found to generate a strong attraction (repulsion) between nearest neighbors of opposite (equal) topological charge. Hence, the emerging short- to mid-range order in the gauge-field configurations screens topological charges. With increasing coupling this order weakens rapidly, however, in part because the dimerons gradually dissociate into their less localized meron constituents. Monitoring confinement properties by evaluating Wilson-loop expectation values, we find the growing disorder due to the long-range tails of these progressively liberated merons to generate a finite and (with the coupling) increasing string tension. The short-distance behavior of the static quark-antiquark potential, on the other hand, is dominated by small, “instantonlike” dimerons. String tension, action density and topological susceptibility of the dimeron ensembles in the physical coupling region turn out to be of the order of standard values. Hence, the above results demonstrate without reliance on weak-coupling or low-density approximations that the dissociating dimeron component in the Yang-Mills vacuum can indeed produce a meron-populated confining phase. The density of coexisting, hardly dissociated and thus instantonlike dimerons seems to remain large enough, on the other hand, to reproduce much of the additional phenomenology successfully accounted for by nonconfining instanton vacuum models. Hence, dimeron ensembles should provide an efficient basis for a more complete description of the Yang-Mills vacuum.

  1. The value of image coregistration during stereotactic radiosurgery.

    PubMed

    Koga, T; Maruyama, K; Igaki, H; Tago, M; Saito, N

    2009-05-01

    Coregistration of any neuroimaging studies into treatment planning for stereotactic radiosurgery became easily applicable using the Leksell Gamma Knife 4C, a new model of gamma knife. The authors investigated the advantage of this image processing. Since installation of the Leksell Gamma Knife 4C at the authors' institute, 180 sessions of radiosurgery were performed. Before completion of planning, coregistration of frameless images of other modalities or previous images was considered to refine planning. Treatment parameters were compared for planning before and after refinement by use of coregistered images. Coregistered computed tomography clarified the anatomical structures indistinct on magnetic resonance imaging. Positron emission tomography visualized lesions disclosing metabolically high activity. Coregistration of prior imaging distinguished progressing lesions from stable ones. Diffusion-tensor tractography was integrated for lesions adjacent to the corticospinal tract or the optic radiation. After refinement of planning in 36 sessions, excess treated volume decreased (p = 0.0062) and Paddick conformity index improved (p < 0.001). Maximal dose to the white matter tracts was decreased (p < 0.001). Image coregistration provided direct information on anatomy, metabolic activity, chronological changes, and adjacent critical structures. This gathered information was sufficiently informative during treatment planning to supplement ambiguous information on stereotactic images, and was useful especially in reducing irradiation to surrounding normal structures.

  2. Five-year Survival After Surgical Removal and Gamma Knife Stereotactic Radiosurgery for a Cerebellar Metastasis from an Esophagogastric Junction Cancer: A Case Report and Literature Review

    PubMed Central

    KANAZAWA, YOSHIKAZU; FUJITA, ITSUO; KAKINUMA, DAISUKE; AOKI, YUTO; KANNO, HITOSHI; ARAI, HIROKI; MATSUNO, KUNIHIKO; SHIMODA, TOMOHIRO; MATSUTANI, TAKESHI; HAGIWARA, NOBUTOSHI; NOMURA, TSUTOMU; YAMADA, TAKESHI; KATO, SHUNJI; NAITO, ZENYA; TAKASAKI, HIDEAKI; UCHIDA, EIJI

    2017-01-01

    Brain metastases originating from esophageal or gastric cancer are rare, accounting for 2.1-3.3% of all brain tumors registered in Japan. There are no established therapeutic measures for brain metastases, which accordingly have a poor prognosis. We present here a patient who survived for 5 years after surgery and gamma knife treatment of a cerebellar metastasis from esophagogastric adenocarcinoma. The primary gastric cancer was treated by laparotomy with total gastrectomy, splenectomy, and D2 lymphadenectomy. It was diagnosed as a esophagogastric junction Siewert type II tumor, type 3, tub1-2, pT3 (SS), pN1, and stage IIB on histopathological examination of the surgical specimen. Five months postoperatively, a solitary cerebellar metastasis was identified and surgically removed, followed by 20 Gy administered by gamma knife stereotactic radiosurgery; the patient received no subsequent treatment such as chemotherapy. Five years after the primary surgery, there have been no recurrences and the patient has a good quality of life. There are very few case reports of long-term survival after surgical treatment of cerebellar metastases from esophagogastric junction cancer. We report our experience and review published case reports of surgical treatment of brain metastases from gastric cancer. PMID:29102948

  3. A simplified model of the source channel of the Leksell GammaKnife® tested with PENELOPE

    NASA Astrophysics Data System (ADS)

    Al-Dweri, Feras M. O.; Lallena, Antonio M.; Vilches, Manuel

    2004-06-01

    Monte Carlo simulations using the code PENELOPE have been performed to test a simplified model of the source channel geometry of the Leksell GammaKnife®. The characteristics of the radiation passing through the treatment helmets are analysed in detail. We have found that only primary particles emitted from the source with polar angles smaller than 3° with respect to the beam axis are relevant for the dosimetry of the Gamma Knife. The photon trajectories reaching the output helmet collimators at (x, y, z = 236 mm) show strong correlations between rgr = (x2 + y2)1/2 and their polar angle thgr, on one side, and between tan-1(y/x) and their azimuthal angle phgr, on the other. This enables us to propose a simplified model which treats the full source channel as a mathematical collimator. This simplified model produces doses in good agreement with those found for the full geometry. In the region of maximal dose, the relative differences between both calculations are within 3%, for the 18 and 14 mm helmets, and 10%, for the 8 and 4 mm ones. Besides, the simplified model permits a strong reduction (larger than a factor 15) in the computational time.

  4. Long-term effectiveness and safety of stereotactic gamma knife surgery as a primary sole treatment in the management of glomus jagulare tumor.

    PubMed

    Hafez, Raef F A; Morgan, Magad S; Fahmy, Osama M; Hassan, Hamdy T

    2018-05-01

    This study aims to report and confirm long-term effectiveness and safety of stereotactic Gamma Knife Surgery as a primary sole treatment in the management of 40 glomus jagulare tumors patients. Retrospective analysis of clinical and radiological outcomes of 40 GJTs consecutive patients treated with GKS as primary sole treatment at International Medical Center (IMC), Cairo-Egypt from the beginning of 2005 till the end of 2014,with mean follow-up period of 84 months (range 36-156 months), mean tumor volume was 6.5 cc, and mean peripheral radiation dose of 15 Gy, to mean isodose curve of 38%. The most common neurological deficit at initial evaluation was bulbar symptoms in 24 patients, followed by pulsatile tinnitus in 22, deterioration of hearing in 20 patients. The overall clinical control achieved in 92.5% of patients, while actuarial tumor size control rate post- GKS was 97.5% at 3 years, 97% at 5 years and 92% at 10 years of follow-up period. Gamma knife surgery could be used effectively and safely as a primary sole treatment tool in the management of glomus jugulare tumors. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Development of stereotactic radiosurgery using carbon beams (carbon-knife)

    NASA Astrophysics Data System (ADS)

    Keawsamur, Mintra; Matsumura, Akihiko; Souda, Hikaru; Kano, Yosuke; Torikoshi, Masami; Nakano, Takashi; Kanai, Tatsuaki

    2018-02-01

    The aim of this research is to develop a stereotactic-radiosurgery (SRS) technique using carbon beams to treat small intracranial lesions; we call this device the carbon knife. A 2D-scanning method is adapted to broaden a pencil beam to an appropriate size for an irradiation field. A Mitsubishi slow extraction using third order resonance through a rf acceleration system stabilized by a feed-forward scanning beam using steering magnets with a 290 MeV/u initial beam energy was used for this purpose. Ridge filters for spread-out Bragg peaks (SOBPs) with widths of 5 mm, 7.5 mm, and 10 mm were designed to include fluence-attenuation effects. The collimator, which defines field shape, was used to reduce the lateral penumbra. The lateral-penumbra width at the SOBP region was less than 2 mm for the carbon knife. The penumbras behaved almost the same when changing the air gap, but on the other hand, increasing the range-shifter thickness mostly broadened the lateral penumbra. The physical-dose rates were approximate 6 Gy s-1 and 4.5 Gy s-1 for the 10  ×  10 mm2 and 5  ×  5 mm2 collimators, respectively.

  6. MR angiography fusion technique for treatment planning of intracranial arteriovenous malformations.

    PubMed

    McGee, Kiaran P; Ivanovic, Vladimir; Felmlee, Joel P; Meyer, Fredrick B; Pollock, Bruce E; Huston, John

    2006-03-01

    To develop an image fusion technique using elliptical centric contrast-enhanced (CE) MR angiography (MRA) and three-dimensional (3D) time-of-flight (TOF) acquisitions for radiosurgery treatment planning of arteriovenous malformations (AVMs). CE and 3D-TOF MR angiograms with disparate in-plane fields of view (FOVs) were acquired, followed by k-space reformatting to provide equal voxel dimensions. Spatial domain addition was performed to provide a third, fused data volume. Spatial distortion was evaluated on an MRA phantom and provided slice-dependent and global distortion along the three physical dimensions of the MR scanner. In vivo validation was performed on 10 patients with intracranial AVMs prior to their conventional angiogram on the day of gamma knife radiosurgery. Spatial distortion in the phantom within a volume of 14 x 14 x 3.2 cm(3) was less than +/-1 mm (+/-1 standard deviation (SD)) for CE and 3D-TOF data sets. Fused data volumes were successfully generated for all 10 patients. Image fusion can be used to obtain high-resolution CE-MRA images of intracranial AVMs while keeping the fiducial markers needed for gamma knife radiosurgery planning. The spatial fidelity of these data is within the tolerance acceptable for daily quality control (QC) purposes and gamma knife treatment planning. (c) 2006 Wiley-Liss, Inc.

  7. Nineteen Victims of Homicide and Attempted Homicide in Sweden-Their Injuries, Cause of Death, and Offender Relationship.

    PubMed

    Khoshnood, Ardavan; Väfors Fritz, Marie; Ekelund, Ulf

    2017-09-01

    Victims of homicide and attempted homicide are not uncommon in Sweden. We therefore aimed to study these victims to understand their injuries, their cause of death, and their relationship to the offender. All cases during five years in a district court in Sweden, where an offender had been convicted for homicide or attempted homicide, were identified and the court documents reviewed. Nineteen victims were identified; 14 males and five females, with an average age of 39.1 years. Although knife/sharp weapon was the most common weapon used, the use of firearm caused more deaths. Our study shows higher rates of firearm use than many other countries. The most common anatomical site to be injured by knife/sharp weapon and firearm was the thorax followed by the head. The most common cause of death was hypovolemia, followed by intracranial injuries. The high rate of firearm use shows that firearms are common modus operandi in Sweden often causing lethal injuries, if the offender intends to kill the victim. Our results support other studies showing that it is foremost injuries to the vessels, intracranial injuries, and injuries to intrathoracic organs, which causes a victim's death when assaulted with knife/sharp weapon or firearm.

  8. 60. VIEW OF ROASTER ADDITION FROM WEST, LOCATION OF SYMONS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    60. VIEW OF ROASTER ADDITION FROM WEST, LOCATION OF SYMONS 3 BY 8 FEET VIBRATING SCREEN. SHOWS BAKER COOLER WITH DUST COLLECTOR DUCT AND DISCHARGE CHUTE ON LEFT. THE 14 INCH BELT CONVEYOR WAS SUPPORTED ON TWO BENTS IN CENTER OF VIEW AS IT CONNECTED WITH THE BUCKET ELEVATOR/ORE BIN TOWER, WHICH IN TURN FED THE ROASTER (BEHIND). THE BASE OF THE ROASTER EXHAUST STACK IS AT THE UPPER RIGHT. - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD

  9. BREAD PRODUCTION WITH RADIOACTIVE CONTAMINATION OF RAW MATERIALS (in German)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ocker, H.-D.

    Protective precautions against radioactive fallout on food materials used for bread production are reviewed. Preventive measures such as dust screening and packing, appeared to be most promising. The decontamination of many concerned foods is either not possible or at this time still not investigated enough. Grain is freed, probably with a good prospect of success, from the dangerous radioisotopes /sup 90/Sr and /sup 137/Cs by precautionary milling methods, so that in times of urgency the provision of radiohygienically unobjectionable bread seems possible. (tr-auth)

  10. 7 CFR 868.310 - Grades and grade requirements for the classes Long Grain Milled Rice, Medium Grain Milled Rice...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Grain Milled Rice, Medium Grain Milled Rice, Short Grain Milled Rice, and Mixed Milled Rice. (See also Â... Milled Rice Principles Governing Application of Standards § 868.310 Grades and grade requirements for the classes Long Grain Milled Rice, Medium Grain Milled Rice, Short Grain Milled Rice, and Mixed Milled Rice...

  11. 7 CFR 868.310 - Grades and grade requirements for the classes Long Grain Milled Rice, Medium Grain Milled Rice...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Grain Milled Rice, Medium Grain Milled Rice, Short Grain Milled Rice, and Mixed Milled Rice. (See also Â... Milled Rice Principles Governing Application of Standards § 868.310 Grades and grade requirements for the classes Long Grain Milled Rice, Medium Grain Milled Rice, Short Grain Milled Rice, and Mixed Milled Rice...

  12. Compilation of data on the uranium and equivalent uranium content of samples analyzed by U.S. Geological Survey during a program of sampling mine, mill, and smelter products

    USGS Publications Warehouse

    Hall, Marlene Louise; Butler, Arthur Pierce

    1952-01-01

    In 1942 the Geological Survey began to collect, in response to a request made by the War Production Board, samples of mine, mill, and smelter products. About 1,400 such samples were collected and analyzed spectrographically for about 20 elements that were of strategic importance, in order to determine whether any of the products analyzed might be possible sources of some of the needed elements. When attention was directed to radioactive elements in 1943, most of the samples were scanned for radioactivity. Part of the work was done on behalf of the Division of Raw Materials of the Atomic Energy Commission. The sources, mine mill, smelter, or prospect, from which these samples were collected, the kind of material sampled, i.e. ores, concentrates, middlings, tailings, flue dusts, and so forth, and the radioactivity of the samples are listed in this report. Samples of the materials collected in the course of the Geological Survey’s investigations for uranium are excluded, but about 500 such samples were analyzed spectrographically for some or all of the same 20 elements sought in the samples that are the subject of this report. Most of the samples were tested only for their radioactivity, but a few were analyzed chemically for uranium. The radioactivity of many of the samples tested in the early screening was determined only qualitatively. Several samples were tested at one time, and if the count obtained did not exceed a predetermined minimum above background, the samples were not tested individually. If the count was more than this minimum, the samples were tested individually to identify the radioactive sample or samples and to obtain a quantitative value for the radioactivity. In general, the rough screening served as a basis for separating samples in which the radioactivity amount to less than 0.003 percent equivalent uranium from those in which it exceeded that amount. Some aspects of various phases of the investigation of radioactivity in these samples have been reported in various other reports, as follows.

  13. Uptake of Uranium and Other Elements of Concern by Plants Growing on Uranium Mill Tailings Disposal Cells

    NASA Astrophysics Data System (ADS)

    Joseph, C. N.; Waugh, W.; Glenn, E.

    2015-12-01

    The U.S. Department of Energy (DOE) is responsible for long-term stewardship of disposal cells for uranium mill tailings throughout the United States. Rock-armored disposal cell covers create favorable habitat for deep-rooted plants by reducing soil evaporation, increasing soil water storage, and trapping windblown dust, thereby providing water and nutrients for plant germination and establishment. DOE is studying the tradeoffs of potential detrimental and beneficial effects of plants growing on disposal cell covers to develop a rational and consistent vegetation management policy. Plant roots often extend vertically through disposal cell covers into underlying tailings, therefore, uptake of tailings contaminants and dissemination through animals foraging on stems and leaves is a possible exposure pathway. The literature shows that plant uptake of contaminants in uranium mill tailings occurs, but levels can vary widely depending on plant species, tailings and soil chemistry, and cover soil hydrology. Our empirical field study measured concentrations of uranium, radium, thorium, molybdenum, selenium, manganese, lead, and arsenic in above ground tissues harvested from plants growing on disposal cells near Native American communities in western states that represent a range of climates, cover designs, cover soil types, and vegetation types. For risk screening, contaminant levels in above ground tissues harvested from plants on disposal cells were compared to Maximum Tolerance Levels (MTLs) set for livestock by the National Research Council, and to tissue levels in the same plant species growing in reference areas near disposal cells. Although tailings were covered with uncontaminated soils, for 14 of 46 comparisons, levels of uranium and other contaminants were higher in plants growing on disposal cells compared to reference area plants, indicating possible mobilization of these elements from the tailing into plant tissues. However, with one exception, all plant levels were well below MTLs. Selenium, the only element that exceeded its MTL, likely originated in local seleniferous soil found both at reference areas and in disposal cell covers, and not in the underlying tailings. Our screening risk assessment suggests that allowing plants to grow on disposal cells appears to be safe.

  14. Jack-knife stretching promotes flexibility of tight hamstrings after 4 weeks: a pilot study.

    PubMed

    Sairyo, Koichi; Kawamura, Takeshi; Mase, Yasuyoshi; Hada, Yasushi; Sakai, Toshinori; Hasebe, Kiyotaka; Dezawa, Akira

    2013-08-01

    Tight hamstrings are reported to be one of the causes of low back pain. However, there have been few reports on effective stretching procedures for the tight hamstrings. The so-called jack-knife stretch, an active-static type of stretching, can efficiently increase the flexibility of tight hamstrings. To evaluate hamstring tightness before and after the 4-week stretching protocol in healthy volunteer adults and patients aged under 18 years with low back pain. For understanding the hamstrings tightness, we measured two parameters including (1) finger to floor distance (FFD) and (2) pelvis forward inclination angle (PFIA). Eight healthy adult volunteers who had no lumbar or hip problems participated in this study (mean age: 26.8 years). All lacked flexibility and their FFD were positive before the experiment. Subjects performed 2 sets of the jack-knife stretch every day for 4 weeks. One set consisted of 5 repetitions, each held for 5 s. Before and during the 4-week experiment, the FFD and PFIA of toe-touching tests were measured weekly. For 17 of the sports players aged under 18, only FFD was measured. In adult volunteers, FFD was 14.1 ± 6.1 cm before the experiment and decreased to -8.1 ± 3.7 cm by the end of week 4, indicating a gain in flexibility of 22.2 cm. PFIA was 50.6 ± 8.2 before the experiment and 83.8 ± 5.8 degrees after. Before and after the experiment, the differences were significant (p < 0.05). For those aged under 18, FFD was 8.1 ± 8.0 and -9.6 ± 6.8, before and after the stretching, respectively. This difference was significant (p < 0.05). The jack-knife stretch is a useful active-static stretching technique to efficiently increase flexibility of tight hamstrings.

  15. SU-E-T-404: Evaluation of the Effect of Spine Hardware for CyberKnife Spinal Stereotactic Radiosurgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuan, J; Zhang, Y; Zheng, Y

    2015-06-15

    Purpose: Spine hardware made of high-Z materials such as titanium has the potential to affect the dose distribution around the metal rods in CyberKnife spinal stereotactic radiosurgery (SRS) treatments. The purpose of this work was to evaluate the magnitude of such effect retrospectively for clinical CyberKnife plans. Methods: The dose calculation was performed within the MultiPlan treatment planning system using the ray tracing (RT) and Monte Carlo (MC) method. A custom density model was created by extending the CT-to-Density table to titanium density of 4.5 g/cm3 with the CT number of 4095. To understand the dose perturbation caused by themore » titanium rod, a simple beam setup (7.5 mm IRIS collimator) was used to irradiate a mimic rod (5 mm) with overridden high density. Five patient spinal SRS cases were found chronologically from 2010 to 2015 in our institution. For each case, the hardware was contoured manually. The original plan was re-calculated using both RT and MC methods with and without rod density override without changing clinical beam parameters. Results: The simple beam irradiation shows that there is 10% dose increase at the interface because of electron backscattering and 7% decrease behind the rod because of photon attenuation. For actual clinical plans, the iso-dose lines and DVHs are almost identical (<2%) for calculations with and without density override for both RT and MC methods. However, there is a difference of more than 10% for D90 between RT and MC method. Conclusion: Although the dose perturbation around the metal rods can be as large as 10% for a single beam irradiation, for clinical treatments with complex beam composition the effect of spinal hardware to the PTV and spinal dose is minimal. As such, the MC dose algorithm without rod density override for CyberKnife spinal SRS is acceptable.« less

  16. Gastric antral webs in adults: A case series characterizing their clinical presentation and management in the modern endoscopic era

    PubMed Central

    Morales, Shannon J; Nigam, Neha; Chalhoub, Walid M; Abdelaziz, Dalia I; Lewis, James H; Benjamin, Stanley B

    2017-01-01

    AIM To investigate the current management of gastric antral webs (GAWs) among adults and identify optimal endoscopic and/or surgical management for these patients. METHODS We reviewed our endoscopy database seeking to identify patients in whom a GAW was visualized among 24640 esophagogastroduodenoscopies (EGD) over a seven-year period (2006-2013) at a single tertiary care center. The diagnosis of GAW was suspected during EGD if aperture size of the antrum did not vary with peristalsis or if a “double bulb” sign was present on upper gastrointestinal series. Confirmation of the diagnosis was made by demonstrating a normal pylorus distal to the GAW. RESULTS We identified 34 patients who met our inclusion criteria (incidence 0.14%). Of these, five patients presented with gastric outlet obstruction (GOO), four of whom underwent repeated sequential balloon dilations and/or needle-knife incisions with steroid injection for alleviation of GOO. The other 29 patients were incidentally found to have a non-obstructing GAW. Age at diagnosis ranged from 30-87 years. Non-obstructing GAWs are mostly incidental findings. The most frequently observed symptom prompting endoscopic work-up was refractory gastroesophageal reflux (n = 24, 70.6%) followed by abdominal pain (n = 11, 33.4%), nausea and vomiting (n = 9, 26.5%), dysphagia (n = 6, 17.6%), unexplained weight loss, (n = 4, 11.8%), early satiety (n = 4, 11.8%), and melena of unclear etiology (n = 3, 8.82%). Four of five GOO patients were treated with balloon dilation (n = 4), four-quadrant needle-knife incision (n = 3), and triamcinolone injection (n = 2). Three of these patients required repeat intervention. One patient had a significant complication of perforation after needle-knife incision. CONCLUSION Endoscopic intervention for GAW using balloon dilation or needle-knife incision is generally safe and effective in relieving symptoms, however repeat treatment may be needed and a risk of perforation exists with thermal therapies. PMID:28101304

  17. SU-F-T-554: Dark Current Effect On CyberKnife Beam Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, H; Chang, A

    Purpose: All RF linear accelerators produce dark current to varying degrees when an accelerating voltage and RF input is applied in the absence of electron gun injection. This study is to evaluate how dark current from the linear accelerator of CyberKnife affect the dose in the reference dosimetry. Methods: The G4 CyberKnife system with 6MV photon beam was used in this study. Using the ion chamber and the diode detector, the dose was measured in water with varying time delay between acquiring charges and staring beam-on after applying high-voltage into the linear accelerator. The dose was measured after the timemore » delay with over the range of 0 to 120 seconds in the accelerating high-voltage mode without beam-on, applying 0, 10, 50, 100, and 200 MUs. For the measurements, the collimator of 60 mm was used and the detectors were placed at the depths of 10 cm with the source-to-surface distance of 80 cm. Results: The dark current was constant over time regardless of MU. The dose due to the dark current increased over time linearly with the R-squared value of 0.9983 up to 4.4 cGy for the time 120 seconds. In the dose rate setting of 720 MU/min, the relative dose when applying the accelerating voltage without beam-on was increased over time up to 0.6% but it was less than the leakage radiation resulted from the accelerated head. As the reference dosimetry condition, when 100 MU was delivered after 10 seconds time delay, the relative dose increased by 0.7% but 6.7% for the low MU (10 MU). Conclusion: In the dosimetry using CyberKnife system, the constant dark current affected to the dose. Although the time delay in the accelerating high-voltage mode without beam-on is within 10 seconds, the dose less than 100 cGy can be overestimated more than 1%.« less

  18. SU-G-TeP2-12: IROCHouston and MDAPL SRS Anthropomorphic Phantom Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Molineu, A; Kry, S; Alvarez, P

    Purpose: To report the results of SRS phantom irradiations Methods: Anthropomorphic SRS head phantoms were sent to institutions participating in NCI sponsored SRS clinical trials and institutions interested in verifying SRS treatment delivery. The phantom shell was purchased from Phantom Laboratory and altered to house dosimetry and imaging inserts. The imaging insert has 1.9 cm diameter spherical target. The dosimetry insert holds two TLD capsules and radiochromic film in the coronal and sagittal planes through the center of the target. Institutions were asked to image, plan and treat the phantom as they would an SRS patient. GammaKnife, CyberKnife and c-armmore » accelerator institutions were asked to cover the target with 15 Gy, 20 Gy and 25 Gy, respectively. Following these guidelines and typical planning protocols for these three types of machines gives roughly 30 Gy to the center of the target for all units. Submission of the DICOM digital data set was required for analysis. Criteria of 5% for TLD results and 85% of pixels passing 5%/3mm gamma analysis were applied beginning in 2013. Results: The phantom was analyzed 269 times between the beginning of 2013 to present. The pass rate is 81%. Nineteen of the irradiation results failed only the TLD criteria, 19 failed only the film criteria and 12 failed both. Irradiations included 32 CyberKnife 23 GammaKnife, 3 TomoTherapy and 211 c-arm units. Planning systems included Eclipse, Ergo, GammaPlan, Hi-Art, iPlan, Monaco, MultiPlan, Pinnacle, RayStation, XiO and XKnife. Irradiations that were not accompanied with DICOM data were not included in this analysis. Conclusion: The phantom is a valuable end-to-end test used to independently verify the accuracy of SRS treatment delivery. This investigation was supported by IROC grant CA180803 awarded by the NCI.« less

  19. FREQUENCY OF POST-OPERATIVE FAECAL INCONTINENCE IN PATIENTS WITH CLOSED AND OPEN INTERNAL ANAL SPHINCTEROTOMY.

    PubMed

    Ghayas, Nighat; Younus, Syed Muneeb; Mirani, Abdul Jabbar; Ghayasuddin, Mohammed; Qazi, Aamna; Suchdev, Sunil Dutt; Bakshi, Saqib Kamran

    2015-01-01

    Fissure in ano is one of the commonest benign and painful proctologic diseases causing considerable morbidity and reduction in quality of life. There are medical as well as surgical treatment options for anal fissure. The study was conducted to compare the frequency of postoperative faecal incontinence in patients with closed lateral internal anal sphincterotomy with von-greaves knife versus standard Park's operation (open method) for chronic anal fissure. This was a randomized controlled trial (RCT) was conducted at the Department of Surgery, KVSS, S.I.T.E. Hospital, Karachi, for a period of six months from 13th February to 12th August 2011. Ninety four consecutive patients having chronic anal fissure were assigned through blocked randomization to groups A & B, with 47 patients in each group. Closed lateral internal anal sphincterotomy (CLIAS) via von-greaves knife was carried out in patients of group-A whereas patients of group-B were subjected to open internal anal sphincterotomy (OIAS) also known as Parks' procedure. Faecal incontinence was noted on the 5th post-operative day. Data was analysed using SPSS 16. There were 81 (86.2%) males and 13 (13.8%) females with male to female ratio being 6:1. Mean age was 38.38 mp ± 14.56 years. Post-operative faecal incontinence in patients undergoing CLIAS was 4.3% while it was 21.3% in those undergoing OIAS with a p-value of 0.027. CLIAS with von-greaves knife is effective in reducing faecal incontinence on 5th postoperative day as compared to standard OIAS. CLIAS with von-greaves knife is effective in reducing faecal incontinence on 5th postoperative day as compared to OIAS (Park's procedure). Therefore, this technique may be used in future regularly to treat chronic anal fissure for prevention of this morbidity.

  20. [Alterations of glial fibrillary acidic protein in rat brain after gamma knife irradiation].

    PubMed

    Ma, Z M; Jiang, B; Ma, J R

    2001-08-28

    To study glial fibrillary acidic protein (GFAP) immunoreactivity in different time and water content of the rat brain treated with gamma knife radiotherapy and to understand the alteration course of the brain lesion after a single high dose radiosurgical treatment. In the brains of the normal rats were irradiated by gamma knife with 160 Gy-high dose. The irradiated rats were then killed on the 1st day, 7th day, 14th day, and 28th day after radiotherapy, respectively. The positive cells of GFAP in brain tissue were detected by immunostaining; the water content of the brain tissue was measured by microgravimetry. The histological study of the irradiated brain tissue was performed with H.E. and examined under light microscope. The numbers of GFAP-positive astrocytes began to increase on the 1st day after gamma knife irradiation. It was enlarged markedly in the number and size of GFAP-stained astrocytes over the irradiated areas. Up to the 28th day, circumscribed necrosis foci (4 mm in diameter) was seen in the central area of the target. In the brain tissue around the necrosis, GFAP-positive astrocytes significantly increased (P < 0.01, compared with the control group). The swelling of cells in irradiated region was observed on the 1st day; after irradiation endothelial cells degenerated and red blood cells escaped from blood vessel on the 7th day; leakage of Evans blue dye was observed in the target region on the 14th day. There was a significant decrease of specific gravity in the irradiated brain tissue the 14th and 28th day after irradiation. The results suggest that GFAP can be used as a marker for the radiation-induced brain injury. The brain edema and disruption of brain-blood barrier can be occurred during the acute stage after irradiation.

  1. Early institution of pre-cutting for difficult biliary cannulation: a prospective study comparing conventional vs. a modified technique.

    PubMed

    Kaffes, Arthur J; Sriram, Parupudi V J; Rao, Guduru V; Santosh, Darisetti; Reddy, D Nageshwar

    2005-11-01

    Pre-cutting techniques have been used to gain biliary access at the expense of an increased complication rate. This may be because of the multiple attempts to achieve cannulation by using standard methods before pre-cutting and causing excess edema and papillary trauma. There are limited data on the early use of pre-cutting techniques. We performed a prospective study of the early introduction of needle-knife techniques in patients with difficult biliary cannulation. Standard biliary cannulation was attempted with a sphincterotome and a guidewire. If this failed within 10 minutes or if there were more than 5 pancreatic cannulations, the needle-knife technique was used. Either a standard method of pre-cutting (below-upward) from the papillary orifice or the modified technique of pre-cutting (above-downward), stopping short of the papillary orifice, was adopted, as per the discretion of the endoscopist. If pre-cutting failed, the cannulation was reattempted 24 to 48 hours later. A total of 346 therapeutic biliary ERCP procedures were performed between April and August 2003. Of these, 70 patients (20%) (mean age, 54 years; 38 men) underwent needle-knife pre-cut sphincterotomy (16 with the standard technique). In 58 patients (83%), the procedure was successful with the initial pre-cutting, making the total success at initial ERCP 334/346 (96.5%). Nine patients in whom pre-cut failed, returned for a second-attempt ERCP, with 7 completed successfully. The total success rate of pre-cutting was 65/70 (93%). The overall success rate of biliary cannulation, after two ERCP attempts, was 341/346 (98.5%). Six patients had mild bleeding, and one had mild pancreatitis. There was no difference in these complications between the two types of pre-cut techniques. The early use of needle knife for difficult biliary cannulation is safe and effective, irrespective of the technique used.

  2. Visual internal urethrotomy for management of urethral strictures in boys: a comparison of short-term outcome of holmium laser versus cold knife.

    PubMed

    Aboulela, Waseem; ElSheemy, Mohammed S; Shoukry, Mahmoud; Shouman, Ahmed M; Shoukry, Ahmed I; Ghoneima, Waleed; El Ghoneimy, Mohamed; Morsi, Hany A; Mohsen, Mostafa Abdel; Badawy, Hesham

    2018-04-01

    To compare efficacy and safety of visual internal urethrotomy (VIU) using holmium laser (Ho:YAG) (group A) versus cold knife (group B) in children with urethral strictures. It may be the first comparative study on this issue in children. This study compared Ho:YAG group, which was evaluated prospectively from January 2014 till January 2016, versus cold knife group, which was a historical control performed from March 2008 till February 2010. Children ≤ 13 years old with urethral strictures ≤ 1.5 cm were included successively. Recurrent cases, congenital obstructions and cases with complete arrest of dye in voiding cystourethrography were excluded. Scar tissue was incised at twelve o'clock. Outcome was compared using Student's t, Mann-Whitney, Chi-square or Fisher exact tests as appropriate. Each group included 21 patients. Mean age was 6.27 ± 3.23 (2-13) years old. Mean stricture length was 1.02 versus 1 cm in group A versus B, respectively (p = 0.862). Ten cases of penile/bulbous strictures and another 11 cases of membranous strictures were found in each group. There was no significant difference between both groups in preoperative data. Success rate for initial VIU was 66.7% in group A versus 38% in group B (p = 0.064). This was associated with significantly higher Q max in group A (mean 16.52 vs 12.09 ml/s; p = 0.03). Success rate after two trials of VIU was 76.2% for group A and 47.61% for group B (p = 0.057). No complications were reported in both groups. Laser VIU has a higher success rate than cold knife VIU for urethral strictures ≤ 1.5 cm in children with significantly higher Q max . Both are easy to perform, low invasive and safe.

  3. Gamma Knife radiosurgery for glomus jugulare tumors: a single-center series of 75 cases.

    PubMed

    Ibrahim, Ramez; Ammori, Mohannad B; Yianni, John; Grainger, Alison; Rowe, Jeremy; Radatz, Matthias

    2017-05-01

    OBJECTIVE Glomus jugulare tumors are rare indolent tumors that frequently involve the lower cranial nerves (CNs). Complete resection can be difficult and associated with lower CN injury. Gamma Knife radiosurgery (GKRS) has established its role as a noninvasive alternative treatment option for these often formidable lesions. The authors aimed to review their experience at the National Centre for Stereotactic Radiosurgery, Sheffield, United Kingdom, specifically the long-term tumor control rate and complications of GKRS for these lesions. METHODS Clinical and radiological data were retrospectively reviewed for patients treated between March 1994 and December 2010. Data were available for 75 patients harboring 76 tumors. The tumors in 3 patients were treated in 2 stages. Familial and/or hereditary history was noted in 12 patients, 2 of whom had catecholamine-secreting and/or active tumors. Gamma Knife radiosurgery was the primary treatment modality in 47 patients (63%). The median age at the time of treatment was 55 years. The median tumor volume was 7 cm 3 , and the median radiosurgical dose to the tumor margin was 18 Gy (range 12-25 Gy). The median duration of radiological follow-up was 51.5 months (range 12-230 months), and the median clinical follow-up was 38.5 months (range 6-223 months). RESULTS The overall tumor control rate was 93.4% with low CN morbidity. Improvement of preexisting deficits was noted in 15 patients (20%). A stationary clinical course and no progression of symptoms were noted in 48 patients (64%). Twelve patients (16%) had new symptoms or progression of their preexisting symptoms. The Kaplan-Meier actuarial tumor control rate was 92.2% at 5 years and 86.3% at 10 years. CONCLUSIONS Gamma Knife radiosurgery offers a risk-versus-benefit treatment option with very low CN morbidity and stable long-term results.

  4. Time-resolved imaging of prompt-gamma rays for proton range verification using a knife-edge slit camera based on digital photon counters

    NASA Astrophysics Data System (ADS)

    Cambraia Lopes, Patricia; Clementel, Enrico; Crespo, Paulo; Henrotin, Sebastien; Huizenga, Jan; Janssens, Guillaume; Parodi, Katia; Prieels, Damien; Roellinghoff, Frauke; Smeets, Julien; Stichelbaut, Frederic; Schaart, Dennis R.

    2015-08-01

    Proton range monitoring may facilitate online adaptive proton therapy and improve treatment outcomes. Imaging of proton-induced prompt gamma (PG) rays using a knife-edge slit collimator is currently under investigation as a potential tool for real-time proton range monitoring. A major challenge in collimated PG imaging is the suppression of neutron-induced background counts. In this work, we present an initial performance test of two knife-edge slit camera prototypes based on arrays of digital photon counters (DPCs). PG profiles emitted from a PMMA target upon irradiation with a 160 MeV proton pencil beams (about 6.5   ×   109 protons delivered in total) were measured using detector modules equipped with four DPC arrays coupled to BGO or LYSO : Ce crystal matrices. The knife-edge slit collimator and detector module were placed at 15 cm and 30 cm from the beam axis, respectively, in all cases. The use of LYSO : Ce enabled time-of-flight (TOF) rejection of background events, by synchronizing the DPC readout electronics with the 106 MHz radiofrequency signal of the cyclotron. The signal-to-background (S/B) ratio of 1.6 obtained with a 1.5 ns TOF window and a 3 MeV-7 MeV energy window was about 3 times higher than that obtained with the same detector module without TOF discrimination and 2 times higher than the S/B ratio obtained with the BGO module. Even 1 mm shifts of the Bragg peak position translated into clear and consistent shifts of the PG profile if TOF discrimination was applied, for a total number of protons as low as about 6.5   ×   108 and a detector surface of 6.6 cm  ×  6.6 cm.

  5. Stereotactic radiosurgery versus stereotactic radiotherapy for patients with vestibular schwannoma: a Leksell Gamma Knife Society 2000 debate.

    PubMed

    Linskey, M E

    2000-12-01

    By definition, the term "radiosurgery" refers to the delivery of a therapeutic radiation dose in a single fraction, not simply the use of stereotaxy. Multiple-fraction delivery is better termed "stereotactic radiotherapy." There are compelling radiobiological principles supporting the biological superiority of single-fraction radiation for achieving an optimal therapeutic response for the slowly proliferating, late-responding, tissue of a schwannoma. It is axiomatic that complication avoidance requires precise three-dimensional conformality between treatment and tumor volumes. This degree of conformality can only be achieved through complex multiisocenter planning. Alternative radiosurgery devices are generally limited to delivering one to four isocenters in a single treatment session. Although they can reproduce dose plans similar in conformality to early gamma knife dose plans by using a similar number of isocenters, they cannot reproduce the conformality of modern gamma knife plans based on magnetic resonance image-targeted localization and five to 30 isocenters. A disturbing trend is developing in which institutions without nongamma knife radiosurgery (GKS) centers are championing and/or shifting to hypofractionated stereotactic radiotherapy for vestibular schwannomas. This trend appears to be driven by a desire to reduce complication rates to compete with modern GKS results by using complex multiisocenter planning. Aggressive advertising and marketing from some of these centers even paradoxically suggests biological superiority of hypofractionation approaches over single-dose radiosurgery for vestibular schwannomas. At the same time these centers continue to use the term radiosurgery to describe their hypofractionated radiotherapy approach in an apparent effort to benefit from a GKS "halo effect." It must be reemphasized that as neurosurgeons our primary duty is to achieve permanent tumor control for our patients and not to eliminate complications at the expense of potential late recurrence. The answer to minimizing complications while maintaining maximum tumor control is improved conformality of radiosurgery dose planning and not resorting to homeopathic radiosurgery doses or hypofractionation radiotherapy schemes.

  6. Stereotactic radiosurgery versus stereotactic radiotherapy for patients with vestibular schwannoma: a Leksell Gamma Knife Society 2000 debate.

    PubMed

    Linskey, Mark E

    2013-12-01

    By definition, the term "radiosurgery" refers to the delivery of a therapeutic radiation dose in a single fraction, not simply the use of stereotaxy. Multiple-fraction delivery is better termed "stereotactic radiotherapy." There are compelling radiobiological principles supporting the biological superiority of single-fraction radiation for achieving an optimal therapeutic response for the slowly proliferating, late-responding, tissue of a schwannoma. It is axiomatic that complication avoidance requires precise three-dimensional conformality between treatment and tumor volumes. This degree of conformality can only be achieved through complex multiisocenter planning. Alternative radiosurgery devices are generally limited to delivering one to four isocenters in a single treatment session. Although they can reproduce dose plans similar in conformality to early gamma knife dose plans by using a similar number of isocenters, they cannot reproduce the conformality of modern gamma knife plans based on magnetic resonance image--targeted localization and five to 30 isocenters. A disturbing trend is developing in which institutions without nongamma knife radiosurgery (GKS) centers are championing and/or shifting to hypofractionated stereotactic radiotherapy for vestibular schwannomas. This trend appears to be driven by a desire to reduce complication rates to compete with modern GKS results by using complex multiisocenter planning. Aggressive advertising and marketing from some of these centers even paradoxically suggests biological superiority of hypofractionation approaches over single-dose radiosurgery for vestibular schwannomas. At the same time these centers continue to use the term radiosurgery to describe their hypofractionated radiotherapy approach in an apparent effort to benefit from a GKS "halo effect." It must be reemphasized that as neurosurgeons our primary duty is to achieve permanent tumor control for our patients and not to eliminate complications at the expense of potential late recurrence. The answer to minimizing complications while maintaining maximum tumor control is improved conformality of radiosurgery dose planning and not resorting to homeopathic radiosurgery doses or hypofractionation radiotherapy schemes.

  7. Reducing the unexpectedly high rate of injuries caused by NOTES gastrotomy creation.

    PubMed

    Sohn, Dae Kyung; Turner, Brian G; Gee, Denise W; Willingham, Field F; Sylla, Patricia; Cizginer, Sevdenur; Konuk, Yusuf; Brugge, William R; Rattner, David W

    2010-02-01

    Despite the wide range of natural orifice transluminal endoscopic surgery (NOTES) procedures reported to date using a transgastric endoscopic approach, complications associated with gastrotomy creation have not been described. This study was conducted to identify the incidence and types of complications related to gastrotomy creation with the needle knife puncture and balloon dilatation technique for NOTES access to the peritoneal cavity. Between May 2007 and August 2008, transgastric procedures were performed in 76 swine at a single institution. A total of 58 gastrotomies were created using the needle knife puncture and balloon dilatation technique without laparoscopic observation and 18 gastrotomies were created under laparoscopic visualization after CO(2) insufflation through a laparoscopic port. In all cases, a needle knife with an electrosurgical current of 25-W coagulation and/or 25-W cut and a wire-guided endoscopic balloon dilated to 20 mm were used to create the gastrotomy. All complications were collected prospectively and reviewed from laboratory medical records, operative reports, and necropsy findings. NOTES gastrotomy-related complications occurred in 10/76 (13.2%) animals. Major complications occurred in six animals (7.9%), including four splenic lacerations, a mesenteric tear, and a fatal diaphragmatic injury. Minor complications occurred in four animals (5.3%), including three abdominal wall injuries and minor gastrotomy site bleeding. When pregastrotomy laparoscopic guidance was used, only one injury occurred in 18 animals (5.5%), but 9/58 (15.5%) gastrotomies performed without laparoscopic visualization caused some type of injury. The difference in rate of injury did not achieve statistical significance. No learning curve effect could be identified. Injuries to adjacent viscera occur more often than is reported with the traditional transgastric needle knife NOTES access technique. Gastric punctures should be made either with laparoscopic visualization or by other techniques such as the PEG approach or with noncutting devices to reduce the incidence of visceral injury associated with transgastric peritoneal entry.

  8. Wounding patterns and human performance in knife attacks: optimising the protection provided by knife-resistant body armour.

    PubMed

    Bleetman, A; Watson, C H; Horsfall, I; Champion, S M

    2003-12-01

    Stab attacks generate high loads, and to defeat them, armour needs to be of a certain thickness and stiffness. Slash attacks produce much lower loads and armour designed to defeat them can be far lighter and more flexible. Phase 1: Human performance in slash attacks: 87 randomly selected students at the Royal Military College of Science were asked to make one slash attack with an instrumented blade on a vertically mounted target. No instructions on how to slash the target were given. The direction, contact forces and velocity of each attack were recorded. Phase 2: Clinical experience with edged weapon attacks: The location and severity of all penetrating injuries in patients attending the Glasgow Royal Infirmary between 1993 and 1996 were charted on anatomical figures. Phase 1: Two types of human slash behaviour were evident: a 'chop and drag' blow and a 'sweep motion' type of attack. 'Chop and drag' attacks had higher peak forces and velocities than sweep attacks. Shoulder to waist blows (diagonal) accounted for 82% of attacks, 71% of attackers used a long diagonal slash with an average cut length of 34 cm and 11% used short diagonal attacks with an average cut length of 25 cm. Only 18% of attackers slashed across the body (short horizontal); the average measured cut length of this type was 28 cm. The maximum peak force for the total sample population was 212 N; the maximum velocity was 14.88 m s(-1). The 95 percentile force for the total sample population was 181 N and the velocity was 9.89 m s(-1). Phase 2: 431 of the 500 patients had been wounded with edged weapons. The average number of wounds sustained by victims in knife assaults was 2.4. The distribution of wounds by frequency and severity are presented. Anti-slash protection is required for the arms, neck, shoulders, and thighs. The clinical experience of knife-attack victims provides information on the relative vulnerabilities of different regions of the body. It is anticipated that designing a tunic-type of Police uniform that is inherently stab and slash resistant will eventually replace the current obvious and often bulky extra protective vest. Attempts at making a combined garment will need to be guided by ergonomic considerations and field testing. A similar anatomical regional risk model might also be appropriate in the design of anti-ballistic armour and combined anti-ballistic and knife-resistant armour.

  9. Geology of the Knife River area, North Dakota

    USGS Publications Warehouse

    Benson, William Edward

    1953-01-01

    The Knife River area, consisting of six 15-minute quadrangles, includes the lower half of the Knife River valley in west-central North Dakota. The area, in the center of the Williston Basin, is underlain by the Tongue River member of the Fort Union formation (Paleocene) and the Golden Valley formation (Eocene). The Tongue River includes beds equivalent to the Sentinel Butte shale; the Golden Valley formation, which receives its first detailed description in this report, consists of two members, a lower member of gray to white sandy kaolin clay and an upper member of cross-bedded micaceous sandstone. Pro-Tongue River rocks that crop out in southwestern North Dakota include the Ludlow member of the Fort Union formation, the Cannonball marine formation (Paleocene) and the Hell Creek, Fox Hills, and Pierre formations, all upper Cretaceous. Post-Golden Valley rocks include the White River formation (Oligocene) and gravels on an old planation surface that may be Miocene or Pliocent. Surficial deposits include glacial and fluvial deposits of Pleistocene age and alluvium, dune sand, residual silica, and landslide blocks of Recent age. Three ages of glacial deposits can be differentiated, largely on the basis of three fills, separated by unconformities, in the Knife River valley. All three are of Wisconsin age and probably represent the Iowan, Tazewell, and Mankato substages. Deposits of the Cary substage have not been identified either in the Knife River area or elsewhere in southern North Dakota. Iowan glacial deposits form the outermost drift border in North Dakota. Southwest of this border are a few scattered granite boulders that are residual from the erosion of either the White River formation or a pre-Wisconsin till. The Tazewell drift border cannot be followed in southern North Dakota. The Mankato drift border can be traced in a general way from the South Dakota State line northwest across the Missouri River and through the middle of the Knife River area. The major land forms of southwestern North Dakota are: (1) high buttes that stand above (2) a gravel-capped planation surface and (3) a gently-rolling upland; below the upland surface are (4) remnants of a broad valley stage of erosion into which (5) modern valleys have been cut. The broad valley profiles of many streams continue east across the Missouri River trench and are part of a former drainage system that flowed into Hudson Bay. Crossing the divides are (6) large trenches, formed when the former northeast-flowing streams were dammed by the glacier and diverted to the southeast. The largest diversion valley is occupied by the Missouri River; another diversion system, now largely abandoned, extends from the Killdeer Mountains southwest to the mouth of Porcupine Creek in Sioux County. By analogy with South Dakota, most of the large diversion valleys are thought to have been cut in Illinoian time. Numerous diversion valleys of Illinoian to late Wisconsin age cut across the divides. Other Pleistocene land forms include ground and moraines, kames, and terraces. Land forms of Recent age include dunes, alluvial terraces, floodplains, and several types of landslide blocks. One type of landslide, called rockslide slump, has not previously been described. Drainage is well adjusted to the structure, most of the streams flowing down the axes of small synclines. The bedrock formations have been gently folded into small domes and synclines that interrupt a gentle northward regional dip into the Williston Basin. Three episodes of deformation affected southwestern North Dakota in Tertiary time: (1) intra-Paleocene, involving warping and minor faulting; (2) post-Eocene, involving uplift and tilting; (2) Oligocene, involving uplift and gentle folding. Mineral resources include ceramic clay, sand and gravel and lignite coal. The Knife River area is the largest lignite-producing district in the United States.

  10. Automated neurovascular tracing and analysis of the knife-edge scanning microscope Rat Nissl data set using a computing cluster.

    PubMed

    Sungjun Lim; Nowak, Michael R; Yoonsuck Choe

    2016-08-01

    We present a novel, parallelizable algorithm capable of automatically reconstructing and calculating anatomical statistics of cerebral vascular networks embedded in large volumes of Rat Nissl-stained data. In this paper, we report the results of our method using Rattus somatosensory cortical data acquired using Knife-Edge Scanning Microscopy. Our algorithm performs the reconstruction task with averaged precision, recall, and F2-score of 0.978, 0.892, and 0.902 respectively. Calculated anatomical statistics show some conformance to values previously reported. The results that can be obtained from our method are expected to help explicate the relationship between the structural organization of the microcirculation and normal (and abnormal) cerebral functioning.

  11. Sound Diffraction Modeling of Rotorcraft Noise Around Terrain

    NASA Technical Reports Server (NTRS)

    Stephenson, James H.; Sim, Ben W.; Chitta, Subhashini; Steinhoff, John

    2017-01-01

    A new computational technique, Wave Confinement (WC), is extended here to account for sound diffraction around arbitrary terrain. While diffraction around elementary scattering objects, such as a knife edge, single slit, disc, sphere, etc. has been studied for several decades, realistic environments still pose significant problems. This new technique is first validated against Sommerfeld's classical problem of diffraction due to a knife edge. This is followed by comparisons with diffraction over three-dimensional smooth obstacles, such as a disc and Gaussian hill. Finally, comparisons with flight test acoustics data measured behind a hill are also shown. Comparison between experiment and Wave Confinement prediction demonstrates that a Poisson spot occurred behind the isolated hill, resulting in significantly increased sound intensity near the center of the shadowed region.

  12. Stereotactic radiosurgery XX: ocular neuromyotonia in association with gamma knife radiosurgery

    PubMed Central

    McQuillan, Joe; Plowman, P Nicholas; MacDougall, Niall; Blackburn, Philip; Sabin, H Ian; Ali, Nadeem; Drake, William M

    2015-01-01

    Summary We report three patients who developed symptoms and signs of ocular neuromyotonia (ONM) 3–6 months after receiving gamma knife radiosurgery (GKS) for functioning pituitary tumours. All three patients were complex, requiring multi-modality therapy and all had received prior external irradiation to the sellar region. Although direct causality cannot be attributed, the timing of the development of the symptoms would suggest that the GKS played a contributory role in the development of this rare problem, which we suggest clinicians should be aware of as a potential complication. Learning points GKS can cause ONM, presenting as intermittent diplopia.ONM can occur quite rapidly after treatment with GKS.Treatment with carbamazepine is effective and improve patient's quality of life. PMID:26294961

  13. A new and innovative use of the thermal knife and Kevlar cord components in a restraint and release system

    NASA Astrophysics Data System (ADS)

    Stewart, Alphonso C.

    2001-09-01

    A Kevlar cord and two thermal knives are key components in the Solar Array Restraint and Release System (SARRS) on the Microwave Anisotropy Probe (MAP) spacecraft at NASA's Goddard Space Flight Center. The SARRS uses a 25-foot (7.62 m) length Kevlar cord that encircles the spacecraft and secures the solar panels in stowed configuration for launch. Once in orbit, one of two redundantly configured thermal knives severs the Kevlar cord and permits the panels to deploy. The purpose of this paper is to present the details of the design, development test results, and the various innovations that were created during the development of this novel use of the thermal knife and Kevlar cord.

  14. A New and Innovative Use of the Thermal Knife and Kevlar Cord Components in a Restraint and Release System

    NASA Technical Reports Server (NTRS)

    Stewart, Alphonso; Brodeur, Stephen J. (Technical Monitor)

    2001-01-01

    A Kevlar cord and two thermal knives are key components in the Soar Array Restraint and Release System (SARRS) on the Microwave Anisotropy Probe (MAP) spacecraft at NASA's Goddard Space Flight Center. The SARRS uses a 25-foot (7.62 m) length Kevlar cord that encircles the spacecraft and secures the solar panels in stowed configuration for launch. Once in orbit, one of two redundantly configured thermal knives severs the Kevlar cord and permits the panels to deploy. The purpose of this paper is to present the details of the design, development test results, and the various innovations that were created during the development of this novel use of the thermal knife and Kevlar cord.

  15. Flue gas desulfurization chemistry studies: limestone grindability. Volume 2. Grindability testing. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richmann, D.L.; Luke, K.W.; Terry, J.C.

    1984-07-01

    The results of a study to determine the relative grindability of US limestones and to relate grindability to petrographic properties are presented in this report. A laboratory ball mill test was developed to provide a quick and simple measure of grindability. These values were then used to explore possible correlations between grindability and the chemical and physical properties of the limestones. Chemical analyses and thin section petrographic analyses were used to characterize the limestone samples. The results of the laboratory ball mill test were compared to the results of an industrial grinding test, the Bond Work Index, for six samplesmore » which covered the grindability range. The two tests compared well with a correlation coefficient greater than 0.9. While the laboratory test is not sufficient to provide ball mill design specifications, it can be used as a screening and quality control test. The grinding results, expressed as a grindability index, ranged in values from 2 to 15. This represents a seven-fold range in the relative difficulties to grind for the limestones tested. From the petrographic analysis results, a strong correlation was found between the grindability and the fraction of macrocrystalline (> 5 ..mu..m) carbonate minerals present in the limestone. However, based on the high degree of variability characteristic of most limestone deposits, petrographic information should, in general, only be used to qualitatively predict the grindability of a specific limestone. An actual grinding test is recommended for a quantitative evaluation.« less

  16. 31. RW Meyer Sugar Mill: 18761889. Threeroll sugar mill: oneton ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    31. RW Meyer Sugar Mill: 1876-1889. Three-roll sugar mill: one-ton daily processing capacity. Manufactured by Edwin Maw, Liverpool, England, ca. 1855-1870. View: View down at the mill from top of the mill's circular masonry enclosure. Mill animals circling above the mill, on top of the enclosure, dragged booms radiating from the drive shaft to power the mill. The drive-shaft is no longer in its upright positon but is lying next to the mill in the foreground. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI

  17. Development of high dispersed TiO2 paste for transparent screen-printable self-cleaning coatings on glass

    NASA Astrophysics Data System (ADS)

    Wang, Yuanhao; Lu, Lin; Yang, Hongxing; Che, Quande

    2013-01-01

    This paper reports a cheap and facile method to fabricate transparent self-cleaning coatings on glass by screen-printing high dispersed TiO2 paste. Three kinds of ZrO2 beads with diameter of 2, 1, and 0.1-0.2 mm were utilized to investigate their influence on the grinding and dispersion of the commercial TiO2 powder in the ball mill. From the SEM images, surface profiler and transmittance spectrum it could be demonstrated that the smallest ZrO2 bead with the diameter of 0.1-0.2 mm was the best candidate to disperse the TiO2 powder into nanoscale size to make the high dispersed TiO2 paste which was the key factor to achieve a smooth, high transparent TiO2 coating. The surface wettability measurement showed that all the screen-printed coatings had super hydrophilic surfaces, which was independent to the surface morphology. However, the coating with the highest transparency showed the lowest photocatalytic activity which is mainly due to the light loss.

  18. Effect of ball milling materials and methods on powder processing of Bi2223 superconductors

    NASA Astrophysics Data System (ADS)

    Yavuz, M.; Maeda, H.; Vance, L.; Liu, H. K.; Dou, S. X.

    1998-10-01

    Various milling systems consisting of agate and polypropylene grinding containers, agate and YSZ balls, and dry and wet milling were used in planetary ball-milling and YSZ balls and YSZ container were used in wet and dry attrition milling. The differently milled powders were then evaluated by measurements of particle size, surface area, porosity, size distribution and chemical analysis of the Si, Zr and C contents. The results show that dry milling is much more efficient for particle size reduction in planetary milling than wet milling, whereas wet milling and dry milling gave quite similar results in attrition milling. Meanwhile 0953-2048/11/10/056/img6 contamination was found in powder milled with an agate container with agate balls. Some C contamination from the polypropylene container was detected after milling, but negligible Zr from YSZ balls and C from the grinding carrier (hexane). It was found that after 1 h milling in the planetary mill fracture mechanisms transform from the elastic to the plastic region. Therefore, further milling is not very effective. It was also shown that the Bi2212 phase decomposes into several non-superconducting oxides such as 0953-2048/11/10/056/img7, CuO and a main amorphous phase after extensive dry milling.

  19. Photons, protons or carbon ions for stage I non-small cell lung cancer - Results of the multicentric ROCOCO in silico study.

    PubMed

    Wink, Krista C J; Roelofs, Erik; Simone, Charles B; Dechambre, David; Santiago, Alina; van der Stoep, Judith; Dries, Wim; Smits, Julia; Avery, Stephen; Ammazzalorso, Filippo; Jansen, Nicolas; Jelen, Urszula; Solberg, Timothy; de Ruysscher, Dirk; Troost, Esther G C

    2018-03-12

    To compare dose to organs at risk (OARs) and dose-escalation possibility for 24 stage I non-small cell lung cancer (NSCLC) patients in a ROCOCO (Radiation Oncology Collaborative Comparison) trial. For each patient, 3 photon plans [Intensity-modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT) and CyberKnife], a double scattered proton (DSP) and an intensity-modulated carbon-ion (IMIT) therapy plan were created. Dose prescription was 60 Gy (equivalent) in 8 fractions. The mean dose and dose to 2% of the clinical target volume (CTV) were lower for protons and ions compared with IMRT (p < 0.01). Doses to the lungs, heart, and mediastinal structures were lowest with IMIT (p < 0.01), doses to the spinal cord were lowest with DSP (p < 0.01). VMAT and CyberKnife allowed for reduced doses to most OARs compared with IMRT. Dose escalation was possible for 8 patients. Generally, the mediastinum was the primary dose-limiting organ. On average, the doses to the OARs were lowest using particles, with more homogenous CTV doses. Given the ability of VMAT and CyberKnife to limit doses to OARs compared with IMRT, the additional benefit of particles may only be clinically relevant in selected patients and thus should be carefully weighed for every individual patient. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Emerging Indications for Fractionated Gamma Knife Radiosurgery.

    PubMed

    McTyre, Emory; Helis, Corbin A; Farris, Michael; Wilkins, Lisa; Sloan, Darrell; Hinson, William H; Bourland, J Daniel; Dezarn, William A; Munley, Michael T; Watabe, Kounosuke; Xing, Fei; Laxton, Adrian W; Tatter, Stephen B; Chan, Michael D

    2017-02-01

    Gamma Knife radiosurgery (GKRS) allows for the treatment of intracranial tumors with a high degree of dose conformality and precision. There are, however, certain situations wherein the dose conformality of GKRS is desired, but single session treatment is contraindicated. In these situations, a traditional pin-based GKRS head frame cannot be used, as it precludes fractionated treatment. To report our experience in treating patients with fractionated GKRS using a relocatable, noninvasive immobilization system. Patients were considered candidates for fractionated GKRS if they had one or more of the following indications: a benign tumor >10 cc in volume or abutting the optic pathway, a vestibular schwannoma with the intent of hearing preservation, or a tumor previously irradiated with single fraction GKRS. The immobilization device used for all patients was the Extend system (Leksell Gamma Knife Perfexion, Elekta, Kungstensgatan, Stockholm). We identified 34 patients treated with fractionated GKRS between August 2013 and February 2015. There were a total of 37 tumors treated including 15 meningiomas, 11 pituitary adenomas, 6 brain metastases, 4 vestibular schwannomas, and 1 hemangioma. At last follow-up, all 21 patients treated for perioptic tumors had stable or improved vision and all 4 patients treated for vestibular schwannoma maintained serviceable hearing. No severe adverse events were reported. Fractionated GKRS was well-tolerated in the treatment of large meningiomas, perioptic tumors, vestibular schwannomas with intent of hearing preservation, and in reirradiation of previously treated tumors.

  1. Single-session Gamma Knife radiosurgery for optic pathway/hypothalamic gliomas.

    PubMed

    El-Shehaby, Amr M N; Reda, Wael A; Abdel Karim, Khaled M; Emad Eldin, Reem M; Nabeel, Ahmed M

    2016-12-01

    OBJECTIVE Because of their critical and central location, it is deemed necessary to fractionate when considering irradiating optic pathway/hypothalamic gliomas. Stereotactic fractionated radiotherapy is considered safer when dealing with gliomas in this location. In this study, the safety and efficacy of single-session stereotactic radiosurgery for optic pathway/hypothalamic gliomas were reviewed. METHODS Between December 2004 and June 2014, 22 patients with optic pathway/hypothalamic gliomas were treated by single-session Gamma Knife radiosurgery. Twenty patients were available for follow-up for a minimum of 1 year after treatment. The patients were 5 to 43 years (median 16 years) of age. The tumor volume was 0.15 to 18.2 cm 3 (median 3.1 cm 3 ). The prescription dose ranged from 8 to 14 Gy (median 11.5 Gy). RESULTS The mean follow-up period was 43 months. Five tumors involved the optic nerve only, and 15 tumors involved the chiasm/hypothalamus. Two patients died during the follow-up period. The tumors shrank in 12 cases, remained stable in 6 cases, and progressed in 2 cases, thereby making the tumor control rate 90%. Vision remained stable in 12 cases, improved in 6 cases, and worsened in 2 cases in which there was tumor progression. Progression-free survival was 83% at 3 years. CONCLUSIONS The initial results indicate that single-session Gamma Knife radiosurgery is a safe and effective treatment option for optic pathway/hypothalamic gliomas.

  2. Thermographic Evaluation of the Hands of Pig Slaughterhouse Workers Exposed to Cold Temperatures.

    PubMed

    Tirloni, Adriana Seára; Reis, Diogo Cunha Dos; Ramos, Eliane; Moro, Antônio Renato Pereira

    2017-07-26

    Brazil was rated the fourth leading producer and exporter of pork meat in the world. The aim of this study was to evaluate the temperature of the hands of pig slaughterhouse workers and its relation to the thermal sensation of the hands and the use of a cutting tool. The study included 106 workers in a pig slaughterhouse. An infrared camera FlirThermaCAM E320 (Flir Systems, Wilsonville, OR, USA) was used to collect the images of the dorsal and palmar surfaces of both hands. A numerical scale was used to obtain the thermal sensation. Chi-square test, Pearson correlation and Student's t test or Wilcoxon were used ( p ≤ 0.05). The majority of workers felt cold in the hands (66%) and workers who used the knife felt the coldest. There was an association between the thermal sensation and the use of knife ( p = 0.001). Workers who used the tool showed correlation between the thermal sensation and the temperatures of the left fingers, with a difference between the temperatures of the right and left hands of those who used the knife ( p ≤ 0.05). The hands (left) that manipulated the products presented the lowest temperatures. Findings indicate that employers of pig slaughterhouses should provide gloves with adequate thermal insulation to preserve the health of workers' hands.

  3. Thermographic Evaluation of the Hands of Pig Slaughterhouse Workers Exposed to Cold Temperatures

    PubMed Central

    Ramos, Eliane

    2017-01-01

    Brazil was rated the fourth leading producer and exporter of pork meat in the world. The aim of this study was to evaluate the temperature of the hands of pig slaughterhouse workers and its relation to the thermal sensation of the hands and the use of a cutting tool. The study included 106 workers in a pig slaughterhouse. An infrared camera FlirThermaCAM E320 (Flir Systems, Wilsonville, OR, USA) was used to collect the images of the dorsal and palmar surfaces of both hands. A numerical scale was used to obtain the thermal sensation. Chi-square test, Pearson correlation and Student’s t test or Wilcoxon were used (p ≤ 0.05). The majority of workers felt cold in the hands (66%) and workers who used the knife felt the coldest. There was an association between the thermal sensation and the use of knife (p = 0.001). Workers who used the tool showed correlation between the thermal sensation and the temperatures of the left fingers, with a difference between the temperatures of the right and left hands of those who used the knife (p ≤ 0.05). The hands (left) that manipulated the products presented the lowest temperatures. Findings indicate that employers of pig slaughterhouses should provide gloves with adequate thermal insulation to preserve the health of workers’ hands. PMID:28933764

  4. Tumour regression of uveal melanoma after ruthenium-106 brachytherapy or stereotactic radiotherapy with gamma knife or linear accelerator.

    PubMed

    Georgopoulos, Michael; Zehetmayer, Martin; Ruhswurm, Irene; Toma-Bstaendig, Sabine; Ségur-Eltz, Nikolaus; Sacu, Stefan; Menapace, Rupert

    2003-01-01

    This study assesses differences in relative tumour regression and internal acoustic reflectivity after 3 methods of radiotherapy for uveal melanoma: (1) brachytherapy with ruthenium-106 radioactive plaques (RU), (2) fractionated high-dose gamma knife stereotactic irradiation in 2-3 fractions (GK) or (3) fractionated linear-accelerator-based stereotactic teletherapy in 5 fractions (Linac). Ultrasound measurements of tumour thickness and internal reflectivity were performed with standardised A scan pre-operatively and 3, 6, 9, 12, 18, 24 and 36 months postoperatively. Of 211 patients included in the study, 111 had a complete 3-year follow-up (RU: 41, GK: 37, Linac: 33). Differences in tumour thickness and internal reflectivity were assessed with analysis of variance, and post hoc multiple comparisons were calculated with Tukey's honestly significant difference test. Local tumour control was excellent with all 3 methods (>93%). At 36 months, relative tumour height reduction was 69, 50 and 30% after RU, GK and Linac, respectively. In all 3 treatment groups, internal reflectivity increased from about 30% initially to 60-70% 3 years after treatment. Brachytherapy with ruthenium-106 plaques results in a faster tumour regression as compared to teletherapy with gamma knife or Linac. Internal reflectivity increases comparably in all 3 groups. Besides tumour growth arrest, increasing internal reflectivity is considered as an important factor indicating successful treatment. Copyright 2003 S. Karger AG, Basel

  5. MRI textures as outcome predictor for Gamma Knife radiosurgery on vestibular schwannoma

    NASA Astrophysics Data System (ADS)

    Langenhuizen, P. P. J. H.; Legters, M. J. W.; Zinger, S.; Verheul, H. B.; Leenstra, S.; de With, P. H. N.

    2018-02-01

    Vestibular schwannomas (VS) are benign brain tumors that can be treated with high-precision focused radiation with the Gamma Knife in order to stop tumor growth. Outcome prediction of Gamma Knife radiosurgery (GKRS) treatment can help in determining whether GKRS will be effective on an individual patient basis. However, at present, prognostic factors of tumor control after GKRS for VS are largely unknown, and only clinical factors, such as size of the tumor at treatment and pre-treatment growth rate of the tumor, have been considered thus far. This research aims at outcome prediction of GKRS by means of quantitative texture feature analysis on conventional MRI scans. We compute first-order statistics and features based on gray-level co- occurrence (GLCM) and run-length matrices (RLM), and employ support vector machines and decision trees for classification. In a clinical dataset, consisting of 20 tumors showing treatment failure and 20 tumors exhibiting treatment success, we have discovered that the second-order statistical metrics distilled from GLCM and RLM are suitable for describing texture, but are slightly outperformed by simple first-order statistics, like mean, standard deviation and median. The obtained prediction accuracy is about 85%, but a final choice of the best feature can only be made after performing more extensive analyses on larger datasets. In any case, this work provides suitable texture measures for successful prediction of GKRS treatment outcome for VS.

  6. Subfornical organ disconnection and Fos-like immunoreactivity in hypothalamic nuclei after intragastric hypertonic saline.

    PubMed

    Starbuck, Elizabeth M; Fitts, Douglas A

    2002-10-04

    The subfornical organ (SFO) may act as a sodium- or osmoreceptor that drives hypothalamic and other nuclei to secrete vasopressin and to elicit drinking. However, in response to mild doses of hypertonic saline, Fos-like immunoreactivity (Fos-ir) is absent in the SFO whereas it is well expressed in the hypothalamic supraoptic (SON) and paraventricular (PVN) nuclei. This suggests that the hypothalamus may be activated in advance of the SFO. In this study, the fibers connecting the SFO and hypothalamus were disconnected by a wire knife cut so that Fos-ir could be examined in both the SFO and hypothalamus after an intragastric (ig) load of 0.5% of body weight of 0.6 M NaCl. Compared with Fos-ir in isotonic-loaded rats, Fos-ir after the hypertonic load was not significantly elevated in the SFO or median preoptic nucleus in sham-cut or knife-cut rats and was only slightly elevated in the OVLT in sham-cut rats. However, the hypertonic load in sham-cut rats greatly elevated Fos-ir in the SON and in the entire PVN, but this expression was reduced significantly by 30-50% in knife-cut rats. Thus, the connectivity between SFO and the hypothalamus is critical for the full expression of Fos-ir in the hypothalamus during moderate ig hypertonic saline loading even when the SFO itself does not yet express Fos-ir.

  7. Comparison of impact of four surgical methods on surgical outcomes in endoscopic dacryocystorhinostomy.

    PubMed

    Roh, Hyun Cheol; Baek, Sehyun; Lee, Hwa; Chang, Minwook

    2016-06-01

    To evaluate differences in the surgical outcomes of endoscopic dacryocystorhinostomy (DCR) according to four different surgical methods. This retrospective study included 222 patients who underwent endoscopic DCR from 2011 to 2013. All patients were assigned to one of four groups according to instruments for incision of nasal mucosa and the formation of mucosal flap: group 1, a sickle knife with mucosal flap; group 2, a sickle knife without mucosal flap; group 3, electrocautery with mucosal flap; and group 4, electrocautery without mucosal flap. The follow up period was at least 6 months. There were 33 eyes in group 1, 44 eyes in group 2, 49 eyes in group 3, and 97 eyes in group 4. There were no significant differences in success rate between groups (P = 0.878). Wound healing time was significantly different between groups (P < 0.001). In post hoc analysis, wound healing time was significantly shorter in group 1 and group 2 than in group 3 and group 4. The vertical ostium size and postsurgical complication were not significantly different between groups. The use of cold instruments such as sickle knife may be more helpful and effective for shortening wound healing time rather than making mucosal flaps in endoscopic DCR. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  8. Long-Term Survival after Gamma Knife Radiosurgery in a Case of Recurrent Glioblastoma Multiforme: A Case Report and Review of the Literature

    PubMed Central

    Thumma, Sudheer R.; Elaimy, Ameer L.; Daines, Nathan; Mackay, Alexander R.; Lamoreaux, Wayne T.; Fairbanks, Robert K.; Demakas, John J.; Cooke, Barton S.; Lee, Christopher M.

    2012-01-01

    The management of recurrent glioblastoma is highly challenging, and treatment outcomes remain uniformly poor. Glioblastoma is a highly infiltrative tumor, and complete surgical resection of all microscopic extensions cannot be achieved at the time of initial diagnosis, and hence local recurrence is observed in most patients. Gamma Knife radiosurgery has been used to treat these tumor recurrences for select cases and has been successful in prolonging the median survival by 8–12 months on average for select cases. We present the unique case of a 63-year-old male with multiple sequential recurrences of glioblastoma after initial standard treatment with surgery followed by concomitant external beam radiation therapy and chemotherapy (temozolomide). The patient was followed clinically as well as with surveillance MRI scans at every 2-3-month intervals. The patient underwent Gamma Knife radiosurgery three times for 3 separate tumor recurrences, and the patient survived for seven years following the initial diagnosis with this aggressive treatment. The median survival in patients with recurrent glioblastoma is usually 8–12 months after recurrence, and this unique case illustrates that aggressive local therapy can lead to long-term survivors in select situations. We advocate that each patient treatment at the time of recurrence should be tailored to each clinical situation and desire for quality of life and improved longevity. PMID:22548078

  9. Initial Experience with the Extracorporeal HIFU Knife with 49 Patients: Japanese Experience

    NASA Astrophysics Data System (ADS)

    Ganaha, F.; Okuno, T.; Lee, C. O.; Shimizu, T.; Osako, K.; Oka, S.; Lee, K. H.; Chen, W. Z.; Zhu, H.; Park, S. H.; Qi, Z.; Shi, D.; Song, H. S.

    2005-03-01

    Forty nine patients with 63 tumours were treated with the Chongqing Haifu knife, as an adjunct to intra-arterial chemoinfusion. Treatment targets included breast (20 lesions), liver (16), bone (8), lymph-node (6), soft tissue (4), lung and pleura (4), pancreas (2), kidney (2) and adrenal gland (1). Follow-up contrast MRI was performed at 3 weeks to assess the effects of HIFU ablation. All cases completed the planned treatment. Of 25 lesions treated with the intention of complete tumour ablation, complete necrosis was obtained in 19 lesions (76%) including 4 secondary success cases. Among 32 lesions having partial and palliative treatment, tumour size was decreased in 6 lesions (21%), and good pain control was obtained in 6 out of 7 patients (86%). Skin injury was the most common complication after HIFU (16%), and was mostly a superficial dermal burn that did not necessitate any treatment. However, there was one patient with deep skin injury at an operation scar which resulted in skin perforation. Other adverse events included soft tissue swelling, prolonged fever, anorexia, persistent pain, shortness of the breath, sacroiliac joint fracture and prolonged diarrhoea. In our limited experience, superficial lesions (e.g. breast cancer, bone, soft tissue, lymph-node and pleural metastasis) appear to be good candidates for HIFU treatment. There appears to be a role for the HIFU knife in pain control for patients with bone metastasis and pancreatic cancer.

  10. Cervical dysplasia - series (image)

    MedlinePlus

    ... is performed using either a knife, laser, or electrocautery. LEEP, or the loop electrosurgical excision procedure is the term used for conization electrocautery. In this procedure, an electric current is run ...

  11. Hemorrhoid surgery

    MedlinePlus

    ... a small rubber band around a hemorrhoid to shrink it by blocking blood flow. Stapling a hemorrhoid to block blood flow, causing it to shrink. Using a knife (scalpel) to remove hemorrhoids. You ...

  12. Development of a size reduction equation for woody biomass: The influence of branch wood properties on Rittinger's constant

    DOE PAGES

    Naimi, Ladan J.; Sokhansanj, Shahabaddine; Bi, Xiaotao; ...

    2015-11-25

    Size reduction is an essential but energy-intensive process for preparing biomass for conversion processes. Three well-known scaling equations (Bond, Kick, and Rittinger) are used to estimate energy input for grinding minerals and food particles. Previous studies have shown that the Rittinger equation has the best fit to predict energy input for grinding cellulosic biomass. In the Rittinger equation, Rittinger's constant (k R) is independent of the size of ground particles, yet we noted large variations in k R among similar particle size ranges. In this research, the dependence of k R on the physical structure and chemical composition of amore » number of woody materials was explored. Branches from two softwood species (Douglas fir and pine) and two hardwood species (aspen and poplar) were ground in a laboratory knife mill. The recorded data included power input, mass flow rate, and particle size before and after grinding. Nine material properties were determined: particle density, solid density (pycnometer and x-ray diffraction methods), microfibril angle, fiber coarseness, fiber length, and composition (lignin and cellulose glucan contents). The correlation matrix among the nine properties revealed high degrees of interdependence between properties. The k R value had the largest positive correlation (+0.60) with particle porosity across the species tested. As a result, particle density was strongly correlated with lignin content (0.85), microfibril angle (0.71), fiber length (0.87), and fiber coarseness (0.78). An empirical model relating k R to particle density was developed.« less

  13. Development of a size reduction equation for woody biomass: The influence of branch wood properties on Rittinger's constant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Naimi, Ladan J.; Sokhansanj, Shahabaddine; Bi, Xiaotao

    Size reduction is an essential but energy-intensive process for preparing biomass for conversion processes. Three well-known scaling equations (Bond, Kick, and Rittinger) are used to estimate energy input for grinding minerals and food particles. Previous studies have shown that the Rittinger equation has the best fit to predict energy input for grinding cellulosic biomass. In the Rittinger equation, Rittinger's constant (k R) is independent of the size of ground particles, yet we noted large variations in k R among similar particle size ranges. In this research, the dependence of k R on the physical structure and chemical composition of amore » number of woody materials was explored. Branches from two softwood species (Douglas fir and pine) and two hardwood species (aspen and poplar) were ground in a laboratory knife mill. The recorded data included power input, mass flow rate, and particle size before and after grinding. Nine material properties were determined: particle density, solid density (pycnometer and x-ray diffraction methods), microfibril angle, fiber coarseness, fiber length, and composition (lignin and cellulose glucan contents). The correlation matrix among the nine properties revealed high degrees of interdependence between properties. The k R value had the largest positive correlation (+0.60) with particle porosity across the species tested. As a result, particle density was strongly correlated with lignin content (0.85), microfibril angle (0.71), fiber length (0.87), and fiber coarseness (0.78). An empirical model relating k R to particle density was developed.« less

  14. Acoustic Neuroma Association

    MedlinePlus

    ... Gold Sponsor NSPC Brain & Spine Surgery Learn More Gold Sponsor University of Colorado Acoustic Neuroma Program and Rocky Mountain Gamma Knife Center Learn More Gold Sponsor USC Acoustic Neuroma Center Learn More Gold ...

  15. Self-harm

    MedlinePlus

    ... have trouble stopping. Examples of self-harm include Cutting yourself (such as using a razor blade, knife, ... them a sense of relief. Some people use cutting as a means to cope with a problem. ...

  16. Study of thermal insulation for airborne liquid hydrogen fuel tanks

    NASA Technical Reports Server (NTRS)

    Ruccia, F. E.; Lindstrom, R. S.; Lucas, R. M.

    1978-01-01

    A concept for a fail-safe thermal protection system was developed. From screening tests, approximately 30 foams, adhesives, and reinforcing fibers using 0.3-meter square liquid nitrogen cold plate, CPR 452 and Stafoam AA1602, both reinforced with 10 percent by weight of 1/16 inch milled OCF Style 701 Fiberglas, were selected for further tests. Cyclic tests with these materials in 2-inch thicknesses bonded on a 0.6-meter square cold plate with Crest 7410 adhesive systems, were successful. Zero permeability gas barriers were identified and found to be compatible with the insulating concept.

  17. A high precision, compact electromechanical ground rotation sensor

    NASA Astrophysics Data System (ADS)

    Dergachev, V.; DeSalvo, R.; Asadoor, M.; Bhawal, A.; Gong, P.; Kim, C.; Lottarini, A.; Minenkov, Y.; Murphy, C.; O'Toole, A.; Peña Arellano, F. E.; Rodionov, A. V.; Shaner, M.; Sobacchi, E.

    2014-05-01

    We present a mechanical rotation sensor consisting of a balance pivoting on a tungsten carbide knife edge. These sensors are important for precision seismic isolation systems, as employed in land-based gravitational wave interferometers and for the new field of rotational seismology. The position sensor used is an air-core linear variable differential transformer with a demonstrated noise floor of {1}{ × 10^{-11}}textrm { m}/sqrt{textrm {Hz}}. We describe the instrument construction and demonstrate low noise operation with a noise floor upper bound of {5.7}{ × 10^{-9}}textrm { rad}/sqrt{textrm {Hz}} at 10 mHz and {6.4}{ × 10^{-10}}textrm { rad}/sqrt{textrm {Hz}} at 0.1 Hz. The performance of the knife edge hinge is compatible with a behaviorur free of noise from dislocation self-organized criticality.

  18. Design and ergonomics. Methods for integrating ergonomics at hand tool design stage.

    PubMed

    Marsot, Jacques; Claudon, Laurent

    2004-01-01

    As a marked increase in the number of musculoskeletal disorders was noted in many industrialized countries and more specifically in companies that require the use of hand tools, the French National Research and Safety Institute (INRS) launched in 1999 a research project on the topic of integrating ergonomics into hand tool design, and more particularly to a design of a boning knife. After a brief recall of the difficulties of integrating ergonomics at the design stage, the present paper shows how 3 design methodological tools--Functional Analysis, Quality Function Deployment and TRIZ--have been applied to the design of a boning knife. Implementation of these tools enabled us to demonstrate the extent to which they are capable of responding to the difficulties of integrating ergonomics into product design.

  19. In memoriam Ladislau Steiner, neurosurgeon: some people from transylvania do live forever.

    PubMed

    Dinca, Eduard B; Ciurea, Alexandru V; Valéry, Charles-Ambroise

    2014-01-01

    We review the extraordinary professional trajectory of Ladislau Steiner, a prolific neurosurgeon and radiosurgeon, who died earlier this year. Dr. Steiner trained and practiced as a neurosurgeon in his native Romania until he was 42, before moving to Stockholm. After 25 years at the Karolinska Institute, when most people consider retirement, he spent the following 25 years of his life as director of the Lars Leksell Center for Gamma Knife Radiosurgery at the University of Virginia, Charlottesville, Virginia. At 90, nostalgia for Europe made him accept the position of director of the Gamma Knife Center at the International Neuroscience Institute in Hannover, Germany. His life was dedicated to the 15,000 patients whose lives he saved in his lengthy career. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Ladislau Steiner, 1920-2013.

    PubMed

    Leksell, Dan; Lindquist, Christer E H

    2013-09-01

    The authors commemorate the life and career of Dr. Ladislau Steiner, one of the world's most highly regarded neurosurgeons, from Stockholm and Charlottesville, Virginia, who has died at age 92. They review the events of Dr. Steiner's early life, including his early training in his native Romania, his escape with his family from East Berlin, and his postgraduate training in neurosurgery at the Karolinska Institute in Stockholm. Dr. Steiner's work in the development of microsurgery and his collaboration with Lars Leksell in the development of Gamma Knife radiosurgery are described. After his retirement from Karolinska, Dr. Steiner had a second career as head of the Lars Leksell Gamma Knife Center at the University of Virginia in Charlottesville. The authors recall their own long association with Dr. Steiner and celebrate his contributions to the field of neurosurgery.

  1. Needle knife-assisted endoscopic polypectomy for a large inflammatory fibroid colon polyp by making its stalk into an omega shape using an endoloop.

    PubMed

    Kim, Byung Chang; Cheon, Jae Hee; Lee, Sang Kil; Kim, Tae Il; Kim, Hoguen; Kim, Won Ho

    2008-08-30

    Colonic inflammatory fibroid polyp (IFP) is an uncommon benign polypoid lesion, which is composed of fibroblasts, numerous small vessels and edematous connective tissue with marked eosinophilic inflammatory cell infiltration. This condition is frequently detected in the stomach and small intestine, but uncommon in the colon. Although IFP is a benign lesion, surgical resections are performed in most colonic cases because the polyps are usually too large to resect endoscopically. Only three patients underwent endoscopic polypectomy in our literature reviews. Here, we present a case of IFP in the descending colon successful endoscopically resected using a novel technique of trapping its stalk with an endoloop, forming the stalk into an omega shape, and then dissecting the stalk with a needle knife.

  2. Bulky Trichomonad Genomes: Encoding a Swiss Army Knife.

    PubMed

    Barratt, Joel; Gough, Rory; Stark, Damien; Ellis, John

    2016-10-01

    The trichomonads are a remarkably successful lineage of ancient, predominantly parasitic protozoa. Recent molecular analyses have revealed extensive duplication of certain genetic loci in trichomonads. Consequently, their genomes are exceptionally large compared to other parasitic protozoa. Retention of these large gene expansions across different trichomonad families raises the question: do these duplications afford an advantage? Many duplicated genes are linked to the parasitic lifestyle and some are regulated differently to their paralogues, suggesting they have acquired new functions. It is proposed that these large genomes encode a Swiss army knife of sorts, packed with a multitude of tools for use in many different circumstances. This may have bestowed trichomonads with the extraordinary versatility that has undoubtedly contributed to their success. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Minimally invasive carpal tunnel decompression using the KnifeLight.

    PubMed

    Hwang, Peter Y K; Ho, Chi Long

    2007-02-01

    Carpal tunnel syndrome is a common condition causing hand pain, dysfunction, and paresthesia. Endoscopic carpal tunnel decompression offers many advantages compared with conventional open surgical decompression. However, it is equipment intensive and requires familiarity with endoscopic surgery. We review a minimally invasive technique to divide the flexor retinaculum by using a new instrument, the KnifeLight (Stryker, Kalamazoo, Michigan), which combines the advantages of the open and endoscopic methods, without the need for endoscopic set-up. Between July 2003 and April 2005, 44 consecutive patients (26 women [59%] and 18 men [36%]), with clinical signs and symptoms, as well as electrodiagnostic findings consistent with carpal tunnel syndrome, who did not respond to non-surgical treatment, underwent the new procedure. All patients were asked about scar hypertrophy, scar tenderness, and pillar pain. The Michigan Hand Outcomes Questionnaire (MHQ) was used to determine overall hand function, activities of daily living, work performance, pain, aesthetics, and satisfaction with hand function. Other preoperative testing included grip strength and lateral pinch strength. Grip strength was measured using the Jamar hand dynamometer (Asimov Engineering Co., Los Angeles, CA); lateral key pinch was measured using the Jamar hydraulic pinch gauge. Postoperative evaluations were scheduled at 2 weeks, 3 months, and 6 months after the procedure. A small 10-mm incision was made in the wrist crease and a small opening was made at the transverse carpal ligament. The KnifeLight tool was inserted, and the ligament was incised completely. Follow-up evaluations with use of quantitative measurements of grip strength, pinch strength, and hand dexterity were performed at 2 weeks, 3 months, and 6 months after surgery. Fifty procedures were performed on 22 left hands (44%) and 28 right hands (56%). There were no complications related to the approach. All patients were able to use their hands immediately after the surgery. Scar tenderness and incisional pain were mild-to-moderate in the first 2 weeks, and these symptoms disappeared completely 6 months after surgery. Significant postoperative improvements in pain relief, patient satisfaction, hand function, daily activities, and work performance as assessed with the MHQ were noted at 3 and 6 months after surgery. Furthermore, significant improvement in patients' hand grip and pinch strength were observed 6 months after surgery. From a literature review, we found that the mean operation time of KnifeLight carpal tunnel release was the shortest compared with the conventional and endoscopic carpal tunnel release techniques. The median time needed for our patients to return to work was also the shortest among the different techniques. Excellent functional outcomes and satisfaction were achieved using the KnifeLight for carpal tunnel decompression. Our minimally invasive method offers a quick, easy, and effective alternative to conventional or endoscopic carpal tunnel decompression.

  4. Stereotactic Arrhythmia Radioablation (STAR) of Ventricular Tachycardia: A Treatment Planning Study

    PubMed Central

    Fahimian, Benjamin; Soltys, Scott G; Zei, Paul; Lo, Anthony; Gardner, Edward A; Maguire, Patrick J; Loo Jr., Billy W

    2016-01-01

    Purpose The first stereotactic arrhythmia radioablation (STAR) of ventricular tachycardia (VT) was delivered at Stanford on a robotic radiosurgery system (CyberKnife® G4) in 2012. The results warranted further investigation of this treatment. Here we compare dosimetrically three possible treatment delivery platforms for STAR. Methods The anatomy and target volume of the first treated patient were used for this study. A dose of 25 Gy in one fraction was prescribed to the planning target volume (PTV). Treatment plans were created on three treatment platforms: CyberKnife® G4 system with Iris collimator (Multiplan, V. 4.6)(Plan #1), CyberKnife® M6 system with InCise 2TM multileaf collimator (Multiplan V. 5.3)(Plan #2) and Varian TrueBeamTM STx with HD 120TM MLC and 10MV flattening filter free (FFF) beam (Eclipse planning system, V.11) (Plan #3 coplanar and #4 noncoplanar VMAT plans). The four plans were compared by prescription isodose line, plan conformity index, dose gradient, as well as dose to the nearby critical structures. To assess the delivery efficiency, planned monitor units (MU) and estimated treatment time were evaluated. Results Plans #1-4 delivered 25 Gy to the PTV to the 75.0%, 83.0%, 84.3%, and 84.9% isodose lines and with conformity indices of 1.19, 1.16, 1.05, and 1.05, respectively. The dose gradients for plans #1-4 were 3.62, 3.42, 3.93, and 3.73 with the CyberKnife® MLC plan (Plan #2) the best, and the TrueBeamTM STx co-planar plan (Plan #3) the worst. The dose to nearby critical structures (lung, stomach, bowel, and esophagus) were all well within tolerance. The MUs for plans #1-4 were 27671, 16522, 6275, and 6004 for an estimated total-treatment-time/beam-delivery-time of 99/69, 65/35, 37/7, and 56/6 minutes, respectively, under the assumption of 30 minutes pretreatment setup time. For VMAT gated delivery, a 40% duty cycle, 2400MU/minute dose rate, and an extra 10 minutes per extra arc were assumed. Conclusion Clinically acceptable plans were created with all three platforms. Plans with MLC were considerably more efficient in MU. CyberKnife® M6 with InCise 2TM collimator provided the most conformal plan (steepest dose drop-off) with significantly reduced MU and treatment time. VMAT plans were most efficient in MU and delivery time. Fluoroscopic image guidance removes the need for additional fiducial marker placement; however, benefits may be moderated by worse dose gradient and more operator-dependent motion management by gated delivery. PMID:27570715

  5. 25. VIEW, LOOKING SOUTHWEST INSIDE TRANSFORMER ROOM, SHOWING TRANSFORMERS AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    25. VIEW, LOOKING SOUTHWEST INSIDE TRANSFORMER ROOM, SHOWING TRANSFORMERS AND KNIFE SWITCHES - Sacramento River Bridge, Spanning Sacramento River at California State Highway 275, Sacramento, Sacramento County, CA

  6. International Radiosurgery Support Association

    MedlinePlus

    ... Tumors Brain Disorders AVMs Radiosurgery Gamma Knife Linac Radiotherapy Overview Childhood Brain Tumors Radiation Therapy Radiation Injury ... Guideline Trigeminal Neuralgia | TN Guideline ... conventional x-ray imaging procedures [New England Journal of Medicine] Read ...

  7. 30. RW Meyer Sugar Mill: 18761889. Threeroll sugar mill: oneton ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    30. RW Meyer Sugar Mill: 1876-1889. Three-roll sugar mill: one-ton daily processing capacity. Manufactured by Edwin Maw, Liverpool, England, ca. 1885-1870. View: Masonry-lined passage-way leading to the mill at the center of its circular masonry enclosure. The passageway permitted cane to be carried to the mill and cane trash (bagasse) to be carried away. Bridges over the passageways, no longer in place, permitted the mill animals to circle and power the mill from above. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI

  8. Stereotactic Radiosurgery - Gamma Knife

    MedlinePlus

    ... nerve that connects the ear to the brain ( acoustic neuroma ) Pituitary tumors Tumors that are not cancer ( ... and the A.D.A.M. Editorial team. Acoustic Neuroma Read more Brain Tumors Read more Radiation ...

  9. Preschooler development

    MedlinePlus

    ... include: Spreading with a knife Drawing a triangle LANGUAGE DEVELOPMENT The 3-year-old uses: Pronouns and prepositions ... why" questions Stuttering may occur in the normal language development of toddlers ages 3 to 4 years. It ...

  10. Cuts and puncture wounds

    MedlinePlus

    ... pointed object such as a nail, knife, or sharp tooth. Symptoms Symptoms include: Bleeding Problems with function ... the last 10 years. Prevention Keep knives, scissors, sharp objects, firearms, and fragile items out of the ...

  11. Stereotactic radiosurgery - CyberKnife

    MedlinePlus

    ... slides into a machine that delivers radiation. A robotic arm controlled by a computer moves around you. ... people who are too high risk for conventional surgery. This may be due to age or other ...

  12. Knife Owners' Protection Act of 2013

    THOMAS, 113th Congress

    Rep. Salmon, Matt [R-AZ-5

    2013-11-13

    House - 01/09/2014 Referred to the Subcommittee on Crime, Terrorism, Homeland Security, and Investigations. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barrett, J C; Karmanos Cancer Institute McLaren-Macomb, Clinton Township, MI; Knill, C

    Purpose: To determine small field correction factors for PTW’s microDiamond detector in Elekta’s Gamma Knife Model-C unit. These factors allow the microDiamond to be used in QA measurements of output factors in the Gamma Knife Model-C; additionally, the results also contribute to the discussion on the water equivalence of the relatively-new microDiamond detector and its overall effectiveness in small field applications. Methods: The small field correction factors were calculated as k correction factors according to the Alfonso formalism. An MC model of the Gamma Knife and microDiamond was built with the EGSnrc code system, using BEAMnrc and DOSRZnrc user codes.more » Validation of the model was accomplished by simulating field output factors and measurement ratios for an available ABS plastic phantom and then comparing simulated results to film measurements, detector measurements, and treatment planning system (TPS) data. Once validated, the final k factors were determined by applying the model to a more waterlike solid water phantom. Results: During validation, all MC methods agreed with experiment within the stated uncertainties: MC determined field output factors agreed within 0.6% of the TPS and 1.4% of film; and MC simulated measurement ratios matched physically measured ratios within 1%. The final k correction factors for the PTW microDiamond in the solid water phantom approached unity to within 0.4%±1.7% for all the helmet sizes except the 4 mm; the 4 mm helmet size over-responded by 3.2%±1.7%, resulting in a k factor of 0.969. Conclusion: Similar to what has been found in the Gamma Knife Perfexion, the PTW microDiamond requires little to no corrections except for the smallest 4 mm field. The over-response can be corrected via the Alfonso formalism using the correction factors determined in this work. Using the MC calculated correction factors, the PTW microDiamond detector is an effective dosimeter in all available helmet sizes. The authors would like to thank PTW (Friedberg, Germany) for providing the PTW microDiamond detector for this research.« less

  14. MAGAT gel and EBT2 film‐based dosimetry for evaluating source plugging‐based treatment plan in Gamma Knife stereotactic radiosurgery

    PubMed Central

    Vivekanandhan, S.; Kale, S.S.; Rath, G.K.; Senthilkumaran, S.; Thulkar, S.; Subramani, V.; Laviraj, M.A.; Bisht, R.K.; Mahapatra, A.K.

    2012-01-01

    This work illustrates a procedure to assess the overall accuracy associated with Gamma Knife treatment planning using plugging. The main role of source plugging or blocking is to create dose falloff in the junction between a target and a critical structure. We report the use of MAGAT gel dosimeter for verification of an experimental treatment plan based on plugging. The polymer gel contained in a head‐sized glass container simulated all major aspects of the treatment process of Gamma Knife radiosurgery. The 3D dose distribution recorded in the gel dosimeter was read using a 1.5T MRI scanner. Scanning protocol was: CPMG pulse sequence with 8 equidistant echoes, TR=7 s, echo step=14 ms, pixel size=0.5 mm x 0.5 mm, and slice thickness of 2 mm. Using a calibration relationship between absorbed dose and spin‐spin relaxation rate (R2), we converted R2 images to dose images. Volumetric dose comparison between treatment planning system (TPS) and gel measurement was accomplished using an in‐house MATLAB‐based program. The isodose overlay of the measured and computed dose distribution on axial planes was in close agreement. Gamma index analysis of 3D data showed more than 94% voxel pass rate for different tolerance criteria of 3%/2 mm, 3%/1 mm and 2%/2 mm. Film dosimetry with GAFCHROMIC EBT 2 film was also performed to compare the results with the calculated TPS dose. Gamma index analysis of film measurement for the same tolerance criteria used for gel measurement evaluation showed more than 95% voxel pass rate. Verification of gamma plan calculated dose on account of shield is not part of acceptance testing of Leksell Gamma Knife (LGK). Through this study we accomplished a volumetric comparison of dose distributions measured with a polymer gel dosimeter and Leksell GammaPlan (LGP) calculations for plans using plugging. We propose gel dosimeter as a quality assurance (QA) tool for verification of plug‐based planning. PACS number: 87.53.Ly, 87.55.‐x, 87.56.N‐ PMID:23149780

  15. Single-port laparoscopic myomectomy using a new single-port transumbilical morcellation system: initial clinical study.

    PubMed

    Kim, Yong-Wook; Park, Byung-Joon; Ro, Duck-Yeong; Kim, Tae-Eung

    2010-01-01

    To evaluate the feasibility of single-port laparoscopic myomectomy with transumbilical morcellation and suturing. Continuing prospective study (Canadian Task Force classification II-3). University hospital. Fifteen patients who underwent single-port laparoscopic myomectomy between September 2008 and October 2009 to remove single or multiple uterine myomas, at least 1 in each patient measuring greater than 4 cm in diameter. All single-port laparoscopic myomectomy procedures were performed by a single surgeon (Dr. Y.W. Kim). Myomas were extracted transumbilically by cutting the myomas into smaller pieces with a knife or a conventional electromechanical morcellator. After making a single 1.5- to 2.0-cm umbilical incision, the single-port system, created with a wound retractor and a surgical glove, was inserted. All operations were performed using conventional rigid straight laparoscopic instruments. Laparoscopic suturing was performed in intramural myomas and some subserosal myomas. Patient mean (SD; range) age was 38.3 (5.6; 29-49) years. The number of myomas per patient was 1.6 (1.4; 1-6). The diameter of the largest myomas was 6.1 (1.5; 4.2-9.6) cm. In 4 patients, only a knife was required for transumbilical extraction of myomas, and in 11 patients, transumbilical morcellation with an electromechanical morcellator with or without a knife was used. Transumbilical drainage tubes were inserted into the pelvic cavity in 11 of 15 patients. Operative time was 96.7 (33.8; 35-150) minutes. The decrease in postoperative hemoglobin concentration was 1.8 (1.2; 0.4-3.6) g/dL. During the operations, no patients required blood transfusion. No patients developed postoperative fever. Neither bowel injury nor urinary tract injury occurred in any patient. The postoperative hospital stay was 3.1 (0.8; 2-4) days. Single-port transumbilical morcellation using a conventional electromechanical morcellator with or without a knife is feasible. Single-port laparoscopic myomectomy is an alternative method with cosmetic advantage. Copyright © 2010 AAGL. Published by Elsevier Inc. All rights reserved.

  16. SU-E-J-240: The Impact On Clinical Dose-Distributions When Using MR-Images Registered with Stereotactic CT-Images in Gamma Knife Radiosurgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Benmakhlouf, H; Kraepelien, T; Forander, P

    2014-06-01

    Purpose: Most Gamma knife treatments are based solely on MR-images. However, for fractionated treatments and to implement TPS dose calculations that require electron densities, CT image data is essential. The purpose of this work is to assess the dosimetric effects of using MR-images registered with stereotactic CT-images in Gamma knife treatments. Methods: Twelve patients treated for vestibular schwannoma with Gamma Knife Perfexion (Elekta Instruments, Sweden) were selected for this study. The prescribed doses (12 Gy to periphery) were delivered based on the conventional approach of using stereotactic MR-images only. These plans were imported into stereotactic CT-images (by registering MR-images withmore » stereotactic CT-images using the Leksell gamma plan registration software). The dose plans, for each patient, are identical in both cases except for potential rotations and translations resulting from the registration. The impact of the registrations was assessed by an algorithm written in Matlab. The algorithm compares the dose-distributions voxel-by-voxel between the two plans, calculates the full dose coverage of the target (treated in the conventional approach) achieved by the CT-based plan, and calculates the minimum dose delivered to the target (treated in the conventional approach) achieved by the CT-based plan. Results: The mean dose difference between the plans was 0.2 Gy to 0.4 Gy (max 4.5 Gy) whereas between 89% and 97% of the target (treated in the conventional approach) received the prescribed dose, by the CT-plan. The minimum dose to the target (treated in the conventional approach) given by the CT-based plan was between 7.9 Gy and 10.7 Gy (compared to 12 Gy in the conventional treatment). Conclusion: The impact of using MR-images registered with stereotactic CT-images has successfully been compared to conventionally delivered dose plans showing significant differences between the two. Although CTimages have been implemented clinically; the effect of the registration has not been fully investigated.« less

  17. WE-DE-BRA-11: A Study of Motion Tracking Accuracy of Robotic Radiosurgery Using a Novel CCD Camera Based End-To-End Test System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, L; M Yang, Y; Nelson, B

    Purpose: A novel end-to-end test system using a CCD camera and a scintillator based phantom (XRV-124, Logos Systems Int’l) capable of measuring the beam-by-beam delivery accuracy of Robotic Radiosurgery (CyberKnife) was developed and reported in our previous work. This work investigates its application in assessing the motion tracking (Synchrony) accuracy for CyberKnife. Methods: A QA plan with Anterior and Lateral beams (with 4 different collimator sizes) was created (Multiplan v5.3) for the XRV-124 phantom. The phantom was placed on a motion platform (superior and inferior movement), and the plans were delivered on the CyberKnife M6 system using four motion patterns:more » static, Sine- wave, Sine with 15° phase shift, and a patient breathing pattern composed of 2cm maximum motion with 4 second breathing cycle. Under integral recording mode, the time-averaged beam vectors (X, Y, Z) were measured by the phantom and compared with static delivery. In dynamic recording mode, the beam spots were recorded at a rate of 10 frames/second. The beam vector deviation from average position was evaluated against the various breathing patterns. Results: The average beam position of the six deliveries with no motion and three deliveries with Synchrony tracking on ideal motion (sinewave without phase shift) all agree within −0.03±0.00 mm, 0.10±0.04, and 0.04±0.03 in the X, Y, and X directions. Radiation beam width (FWHM) variations are within ±0.03 mm. Dynamic video record showed submillimeter tracking stability for both regular and irregular breathing pattern; however the tracking error up to 3.5 mm was observed when a 15 degree phase shift was introduced. Conclusion: The XRV-124 system is able to provide 3D and 4D targeting accuracy for CyberKnife delivery with Synchrony. The experimental results showed sub-millimeter delivery in phantom with excellent correlation in target to breathing motion. The accuracy was degraded when irregular motion and phase shift was introduced.« less

  18. SU-E-J-06: Additional Imaging Guidance Dose to Patient Organs Resulting From X-Ray Tubes Used in CyberKnife Image Guidance System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, A; Ding, G

    Purpose: The use of image-guided radiation therapy (IGRT) has become increasingly common, but the additional radiation exposure resulting from repeated image guidance procedures raises concerns. Although there are many studies reporting imaging dose from different image guidance devices, imaging dose for the CyberKnife Robotic Radiosurgery System is not available. This study provides estimated organ doses resulting from image guidance procedures on the CyberKnife system. Methods: Commercially available Monte Carlo software, PCXMC, was used to calculate average organ doses resulting from x-ray tubes used in the CyberKnife system. There are seven imaging protocols with kVp ranging from 60 – 120 kVmore » and 15 mAs for treatment sites in the Cranium, Head and Neck, Thorax, and Abdomen. The output of each image protocol was measured at treatment isocenter. For each site and protocol, Adult body sizes ranging from anorexic to extremely obese were simulated since organ dose depends on patient size. Doses for all organs within the imaging field-of-view of each site were calculated for a single image acquisition from both of the orthogonal x-ray tubes. Results: Average organ doses were <1.0 mGy for every treatment site and imaging protocol. For a given organ, dose increases as kV increases or body size decreases. Higher doses are typically reported for skeletal components, such as the skull, ribs, or clavicles, than for softtissue organs. Typical organ doses due to a single exposure are estimated as 0.23 mGy to the brain, 0.29 mGy to the heart, 0.08 mGy to the kidneys, etc., depending on the imaging protocol and site. Conclusion: The organ doses vary with treatment site, imaging protocol and patient size. Although the organ dose from a single image acquisition resulting from two orthogonal beams is generally insignificant, the sum of repeated image acquisitions (>100) could reach 10–20 cGy for a typical treatment fraction.« less

  19. Choledochoscopic high-frequency needle-knife electrotomy for treatment of anastomotic strictures after Roux-en-Y hepaticojejunostomy.

    PubMed

    Yang, Yu-Long; Zhang, Cheng; Wu, Ping; Ma, Yue-Feng; Li, Jing-Yi; Zhang, Hong-Wei; Shi, Li-Jun; Lin, Mei-Ju; Yu, Ying

    2016-05-06

    Anastomotic stricture is a complex and substantial complication following Roux-en-Y hepaticojejunostomy. Initially, endoscopic and percutaneous approaches are often attempted, but the gold standard remains surgical biliary reconstruction, especially for refractory stricture. However, this solution leaves much room for improvement, due to the challenging nature of the biliary reconstruction procedure, in which anastomotic stricture may still occur. To investigate the feasibility and effectiveness of choledochoscopic high-frequency needle-knife electrotomy as an intervention in the treatment of anastomotic strictures following Roux-en-Y hepaticojejunostomy. From February 2010 to October 2014, clinical data was collected and retrospectively compared for patients who underwent balloon dilation or/and choledochoscopic high-frequency needle-knife electrotomy for the treatment of anastomotic strictures after Roux-en-Y hepaticojejunostomy. A total of 38 patients underwent successful choledochoscopic treatment and all the anastomotic strictures were removed successfully, 19 of which were treated with electrotomy, 7 with balloon dilation, and 12 with both electrotomy and balloon dilation. Among these groups,the average operating times were 6.9 ± 2.4 min,10.1 ± 6.8 min, and 20.2 ± 13.5 min, respectively. The average stent supporting times were 6.3 ± 0.7 months, 6.5 ± 0.6 months, and 6.1 ± 0.4 respectively. The mean follow-up after stent removal was 42.1 ± 27.4 months, and in 26.3 % (5/19), 28.5 % (2/7) and 16.7 % (2/12) of cases, recurrent anastomotic stricture occurred. Of these 9 total patients with recurrent anastomotic, two patients were successfully rescued by full-covered self-expanding removable metal stents and 7 patients by electrotomy combined with balloon dilation. Choledochoscopic high-frequency needle-knife electrotomy is both feasible and safe in the treatment of anastomotic stricture after Roux-en-Y hepaticojejunostomy, with a similar long-term outcome to balloon dilation in treating anastomotic stricture after Roux-en-Y hepaticojejunostomy. A combination of choledochoscopic electrotomy concurrent with balloon dilation should be recommended based on the low rate of recurrence.

  20. SU-F-T-293: Experimental Comparisons of Ionization Chambers with Different Volumes for CyberKnife Delivery Quality Assurance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakayama, M; Kobe University Graduate School of Medicine, Kobe, Hyogo; Munetomo, Y

    2016-06-15

    Purpose: To evaluate the practicality use of ionization chambers with different volumes for delivery quality assurance of CyberKnife plans, Methods: Dosimetric measurements with a spherical solid water phantom and three ionization chambers with volumes of 0.13, 0.04, and 0.01 cm3 (IBA CC13, CC04, and CC01, respectively) were performed for various CyberKnife clinical treatment plans including both isocentric and nonisocentric delivery. For each chamber, the ion recombination correction factors Ks were calculated using the Jaffe plot method and twovoltage method at a 10-cm depth for a 60-mm collimator field in a water phantom. The polarity correction factors Kpol were determined formore » 5–60-mm collimator fields in same experimental setup. The measured doses were compared to the doses for the detectors calculated using a treatment planning system. Results: The differences in the Ks between the Jaffe plot method and two-voltage method were −0.12, −0.02, and 0.89% for CC13, CC04, and CC01, respectively. The changes in Kpol for the different field sizes were 0.2, 0.3, and 0.8% for CC13, CC04, and CC01, respectively. The measured doses for CC04 and CC01 were within 3% of the calculated doses for the clinical treatment plans with isocentric delivery with collimator fields greater than 12.5 mm. Those for CC13 had differences of over 3% for the plans with isocentric delivery with collimator fields less than 15 mm. The differences for the isocentric plans were similar to those for the single beam plans. The measured doses for each chamber were within 3% of the calculated doses for the non-isocentric plans except for that with a PTV volume less than 1.0 cm{sup 3}. Conclusion: Although there are some limitations, the ionization chamber with a smaller volume is a better detector for verification of the CyberKnife plans owing to the high spatial resolution.« less

  1. SU-E-T-563: Multi-Fraction Stereotactic Radiosurgery with Extend System of Gamma Knife: Treatment Verification Using Indigenously Designed Patient Simulating Multipurpose Phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bisht, R; Kale, S; Gopishankar, N

    2015-06-15

    Purpose: Aim of the study is to evaluate mechanical and radiological accuracy of multi-fraction regimen and validate Gamma knife based fractionation using newly developed patient simulating multipurpose phantom. Methods: A patient simulating phantom was designed to verify fractionated treatments with extend system (ES) of Gamma Knife however it could be used to validate other radiotherapy procedures as well. The phantom has options to insert various density material plugs and mini CT/MR distortion phantoms to analyze the quality of stereotactic imaging. An additional thorax part designed to predict surface doses at various organ sites. The phantom was positioned using vacuum headmore » cushion and patient control unit for imaging and treatment. The repositioning check tool (RCT) was used to predict phantom positioning under ES assembly. The phantom with special inserts for film in axial, coronal and sagittal plane were scanned with X-Ray CT and the acquired images were transferred to treatment planning system (LGP 10.1). The focal precession test was performed with 4mm collimator and an experimental plan of four 16mm collimator shots was prepared for treatment verification of multi-fraction regimen. The prescription dose of 5Gy per fraction was delivered in four fractions. Each fraction was analyzed using EBT3 films scanned with EPSON 10000XL Scanner. Results: The measurement of 38 RCT points showed an overall positional accuracy of 0.28mm. The mean deviation of 0.28% and 0.31 % were calculated as CT and MR image distortion respectively. The radiological focus accuracy test showed its deviation from mechanical center point of 0.22mm. The profile measurement showed close agreement between TPS planned and film measured dose. At tolerance criteria of 1%/1mm gamma index analysis showed a pass rate of > 95%. Conclusion: Our results show that the newly developed multipurpose patient simulating phantom is highly suitable for the verification of fractionated stereotactic radiosurgery using ES of Gamma knife. The study is a part of intramural research project of Research Section, All India Institute of Medical Sciences New Delhi India (A 247)« less

  2. 12. TROJAN MILL, INTERIOR SHOWING PRIMARY MILL No. 1 (MONADNOCK ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. TROJAN MILL, INTERIOR SHOWING PRIMARY MILL No. 1 (MONADNOCK CHILEAN) FROM EAST, c. 1912. ELEVATOR No. 1 ADJACENT TO MILL. CREDIT WR. - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD

  3. Knife Owners' Protection Act of 2014

    THOMAS, 113th Congress

    Sen. Enzi, Michael B. [R-WY

    2014-01-16

    Senate - 01/16/2014 Read twice and referred to the Committee on Commerce, Science, and Transportation. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  4. Loop Electrosurgical Excision Procedure (LEEP)

    MedlinePlus

    ... that acts like a scalpel (surgical knife). An electric current is passed through the loop, which cuts ... A procedure in which an instrument works with electric current to destroy tissue. Local Anesthesia: The use ...

  5. 12. RW Meyer Sugar Mill: 18761889. Threeroll sugar mill: oneton ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. RW Meyer Sugar Mill: 1876-1889. Three-roll sugar mill: one-ton daily processing capacity. Manufactured by Edwin Maw, Liverpool, England, ca. 1855-1870. View: Historical view, 1934, T.T. Waterman Collection, Hawaiian Sugar Planters' Association, Oahu, Hawaii. Masonry-lined passageway leading to the mill at the center of its circular masonry enclosure. The passageway permitted cane to be carried to the mill and cane trash (bagasse) to be carried away after milling. Bridges over the passageways, not in place, permitted the mill animals to circle and power the mill from above. View shows area prior to substantial overgrowth existing in 1978 views of the area. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI

  6. Aqueous extracts of avocado pear (Persea americana Mill.) leaves and seeds exhibit anti-cholinesterases and antioxidant activities in vitro.

    PubMed

    Oboh, Ganiyu; Odubanjo, Veronica O; Bello, Fatai; Ademosun, Ayokunle O; Oyeleye, Sunday I; Nwanna, Emem E; Ademiluyi, Adedayo O

    2016-03-01

    Avocado pear (Persea americana Mill.) leaves and seeds are used in traditional medicine for the treatment/management of Alzheimer disease (AD); however, information on the mechanism of actions is limited. This study sought to investigate the effect of P. americana leaf and seed aqueous extracts on some enzymes linked with AD (acetylcholinesterase [AChE] and butyrylcholinesterase [BChE] activities) and their antioxidant potentials in vitro. The inhibitory effects of extracts on AChE and BChE activities and antioxidant potentials (inhibition of Fe2+- and sodium nitroprusside-induced thiobarbiturate reactive species [TBARS] production in rat brain homogenates, radicals [1,1-diphenyl-2-picrylhydrazyl, hydroxyl, and nitric oxide] scavenging and iron [Fe] chelation abilities) were investigated. Phenolic content and phytochemical screening were carried out. Alkaloid profile was also determined using gas chromatography coupled with flame ionization detector (GC-FID). The extracts inhibited AChE and BChE activities and prooxidant-induced TBARS production in a dose-dependent manner, with the seed extract having the highest inhibitory effect and the leaf extract exhibiting higher phenolic content and radical scavenging abilities, but lower Fe chelation ability compared with that of the seed. The phytochemical screening revealed the presence of saponins, alkaloids, and terpenoids in both extracts, whereas the total alkaloid profile was higher in the seed extract than in the leaf extract, as revealed by GC-FID. The anti-cholinesterase and antioxidant activities of avocado leaf and seed could be linked to their phytoconstituents and might be the possible mechanisms underlying their use as a cheap and natural treatment/management of AD. However, these extracts should be further investigated in vivo.

  7. Recycling of a fine, heavy fluff automobile shredder residue by density and differential fragmentation.

    PubMed

    Gent, M R; Menéndez, M; Muñiz, H; Torno, S

    2015-09-01

    A compilation of the physical properties of materials which might typically occur in automobile shredder residue and an analysis of their suitability for the separation of materials in fine (<15mm) heavy fluff ASR (fhf-ASR) is presented. Differences in density and resistance to crushing of fhf-ASR materials were identified as potentially the most suitable low cost, technologically simple means for the separating this waste into its three principal components - metals, minerals (glass/stones) and organics (plastics). Results presented of laboratory scale tests demonstrate that fhf-ASR can in large part be separated into three principal components. Tests were conducted with 0.63-2.0mm and 2-10mm fractions. Recovery of plastics by density separations were conducted with water only jigs for the 2-10mm fraction and shaker tables for the 0.63-2mm fraction. Comparisons are presented of the separations of glass and stones from metals obtained by linear screening and vibratory screening of roller mill and impact mill crushing products of the high density 2-10mm fraction. Equipment used for these tests are of a laboratory or demonstrative scale. It is reasonable to anticipate that industrial scale processing would produce significantly better results. The 2-15mm fraction was found to constitute 91.6% of the fhf-ASR sampled. The metals content of the 2-10mm portion of this fraction was upgraded from 2.5% to 31% and 76.9% with recoveries varying inversely with grade from 91.9% to 40.1%. From 63.6% to 17.1% with a recovery of 93.5% of the organic materials. A residual product of fine sand of crushed glass/stones of 99.4% purity recovered 71.3% of these. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Investigations on the effect of forage source, grinding, and urea supplementation on ruminal fermentation and microbial protein flow in a semi-continuous rumen simulation system.

    PubMed

    Hildebrand, Bastian; Boguhn, Jeannette; Rodehutscord, Markus

    2011-10-01

    The objective of the present study was to compare the effect of maize silage and grass silage on microbial fermentation and protein flow in a semi-continuous rumen simulation system (Rusitec) when milling screen size (MSS) during grinding was varied. Oven-dried silages were milled through screens of 1, 4 or 9 mm pore size and incubated for 48 h in a Rusitec system. Furthermore, the effect of N supplementation to maize silage (MSS: 4 mm) was investigated and single dose vs. continuous infusion of urea-N were compared. Degradation of organic matter (OM), crude protein (CP), fibre fractions and non-structural carbohydrates (NSC) as well as short-chain fatty acid production differed significantly between forage sources. Urea-N supplementation improved the degradation of NSC, but not that of fibre fractions in maize silage. The way of urea supply had only marginal effects on fermentation characteristics. An increase in MSS, and consequently in mean feed particle size, led to an improvement in the degradation of OM, CP and NSC, but efficiency of microbial net protein synthesis (EMPS; mg microbial N flow/g degraded OM) and the microbial amino acid profile were less affected. EMPS was higher in grass silage than in maize silage and was improved by urea-N supplementation in maize silage. This study indicates that fermentation of NSC as well as EMPS during incubation of maize silage was limited by availability of NH3-N. Furthermore, an increase in MSS above 1 mm seems to improve fermentation of silages in the Rusitec system.

  9. 13. TROJAN MILL, INTERIOR SHOWING PRIMARY MILL No. 1 (ALLIS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. TROJAN MILL, INTERIOR SHOWING PRIMARY MILL No. 1 (ALLIS CHALMERS BALL MILL) FROM EAST, c. 1919. ELECTRIC MOTOR AND DRIVE SHAFT CLEARLY VISIBLE. CREDIT WR. - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD

  10. 76 FR 2409 - Proclaiming Certain Lands, Lot 32 Acquisition, as an Addition to the Bay Mills Indian Reservation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-13

    ..., as an Addition to the Bay Mills Indian Reservation for the Bay Mills Indian Community of Michigan..., more or less, to be added to the Bay Mills Indian Reservation for the Bay Mills Indian Community of... Mills Indian Reservation and part of the Bay Mills Indian Community of Michigan for the exclusive use of...

  11. 33. RW Meyer Sugar Mill: 18761889. Threeroll sugar mill, oneton ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    33. RW Meyer Sugar Mill: 1876-1889. Three-roll sugar mill, one-ton daily processing capacity. Manufactured by Edwin Maw, Liverpool, England, ca. 1855-1870. View: From above the mill showing the three 15' x 22' horizontal rolls, mill frame or cheeks, portland cement foundation, and lower part of vertical drive shaft lying next mill in foreground. The loose metal piece resting on top of the mill frame matched the indented portion of the upper frame to form a bracket and bearing for the drive shaft when it was in its proper upright position. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI

  12. Effects of milling on functional properties of rice flour.

    PubMed

    Kadan, R S; Bryant, R J; Miller, J A

    2008-05-01

    A commercial long-grain rice flour (CRF) and the flours made by using a pin mill and the Udy mill from the same batch of broken second-head white long-grain rice were evaluated for their particle size and functional properties. The purpose of this study was to compare the commercial rice flour milling method to the pin and Udy milling methods used in our laboratory and pilot plant. The results showed that pin milled flour had more uniform particle size than the other 2 milled flours. The chalky kernels found in broken white milled rice were pulverized more into fines in both Udy milled flour and CRF than in the pin milled flour. The excessive amount of fines in flours affected their functional properties, for example, WSI and their potential usage in the novel foods such as rice breads (RB). The RB made from CRF collapsed more than loaves made from pin milled Cypress long-grain flours.

  13. Everyday Life with ALS: A Practical Guide

    MedlinePlus

    ... best possible quality of life. A major theme running through this guide is the importance of planning ... glass when drinking. This knife has a curved blade and an enlarged handle. You can cut food ...

  14. Seal For Precooling A Turbopump

    NASA Technical Reports Server (NTRS)

    Owen, Samuel S.; Mulready, R.C.

    1988-01-01

    Diaphragm reduces misalignment. Rotary seal retains precooling fluid in pump section of cryogenic turbopump, preventing fluid from entering turbine section. Precooling fluid held in pump section of turbopump by knife-edge labyrinth seal on diaphragm.

  15. A Simple, Inexpensive Water-Leveling Device for Ultramicrotomy.

    ERIC Educational Resources Information Center

    Brooks, Austin E.

    1978-01-01

    Describes a device for maintaining the proper water level in knife boats during ultramicrotomy. Water levels in troughs are adjusted rapidly and precisely during the cutting process. Illustrations are included. (Author/MA)

  16. Diaphragm flange and method for lowering particle beam impedance at connected beam tubes of a particle accelerator

    DOEpatents

    Biallas, George Herman

    2017-07-04

    A diaphragm flange for connecting the tubes in a particle accelerator while minimizing beamline impedance. The diaphragm flange includes an outer flange and a thin diaphragm integral with the outer flange. Bolt holes in the outer flange provide a means for bolting the diaphragm flange to an adjacent flange or beam tube having a mating bolt-hole pattern. The diaphragm flange includes a first surface for connection to the tube of a particle accelerator beamline and a second surface for connection to a CF flange. The second surface includes a recessed surface therein and a knife-edge on the recessed surface. The diaphragm includes a thickness that enables flexing of the integral diaphragm during assembly of beamline components. The knife-edge enables compression of a soft metal gasket to provide a leak-tight seal.

  17. Micromachined electrical cauterizer

    DOEpatents

    Lee, Abraham P.; Krulevitch, Peter A.; Northrup, M. Allen

    1999-01-01

    A micromachined electrical cauterizer. Microstructures are combined with microelectrodes for highly localized electro cauterization. Using boron etch stops and surface micromachining, microneedles with very smooth surfaces are made. Micromachining also allows for precision placement of electrodes by photolithography with micron sized gaps to allow for concentrated electric fields. A microcauterizer is fabricated by bulk etching silicon to form knife edges, then parallelly placed microelectrodes with gaps as small as 5 .mu.m are patterned and aligned adjacent the knife edges to provide homeostasis while cutting tissue. While most of the microelectrode lines are electrically insulated from the atmosphere by depositing and patterning silicon dioxide on the electric feedthrough portions, a window is opened in the silicon dioxide to expose the parallel microelectrode portion. This helps reduce power loss and assist in focusing the power locally for more efficient and safer procedures.

  18. Soup-can Pendulum

    NASA Astrophysics Data System (ADS)

    Peters, Randall D.

    2004-11-01

    In these studies, a vegetable can containing fluidwas swung as a pendulum by supporting its end-lipswith a pair of knife edges. The motion was measuredwith a capacitive sensor and the logarithmic decrementin free decay was estimated from computer-collectedrecords. Measurements performed with nine differenthomogeneous liquids, distributed through six decadesin the viscosity η, showed that the damping ofthe system is dominated by η rather than externalforces from air or the knife edges. The log decrementwas found to be maximum (0.28) in the vicinity ofη = 0.7 Pa s and fell off more than 15 fold(below 2 × 10-2) for both small viscosity(η < 1 × 10-3 Pa s) and also for largeviscosity (η > 1 × 103 Pa s). A simple modelhas been formulated, which yields reasonable agreementbetween theory and experiment by approximating therelative rotation of can and liquid.

  19. Micromachined electrical cauterizer

    DOEpatents

    Lee, A.P.; Krulevitch, P.A.; Northrup, M.A.

    1999-08-31

    A micromachined electrical cauterizer is disclosed. Microstructures are combined with microelectrodes for highly localized electro cauterization. Using boron etch stops and surface micromachining, microneedles with very smooth surfaces are made. Micromachining also allows for precision placement of electrodes by photolithography with micron sized gaps to allow for concentrated electric fields. A microcauterizer is fabricated by bulk etching silicon to form knife edges, then parallelly placed microelectrodes with gaps as small as 5 {mu}m are patterned and aligned adjacent the knife edges to provide homeostasis while cutting tissue. While most of the microelectrode lines are electrically insulated from the atmosphere by depositing and patterning silicon dioxide on the electric feedthrough portions, a window is opened in the silicon dioxide to expose the parallel microelectrode portion. This helps reduce power loss and assist in focusing the power locally for more efficient and safer procedures. 7 figs.

  20. JT8D revised high-pressure turbine cooling and other outer air seal program

    NASA Technical Reports Server (NTRS)

    Gaffin, W. O.

    1979-01-01

    The JT8D high pressure turbine was revised to reduce leakage between the blade tip shrouds and the outer air seal, and engine testing was performed to determine the effect on performance. The addition of a second knife-edge on the blade tip shroud, the extension of the honeycomb seal land to cover the added knife-edge and an existing spoiler on the shroud, and a material substitution in the seal support ring to improve thermal growth characteristics are included. A relocation of the blade cooling air discharge to insure adequate cooling flow is required. Significant specific fuel consumption and exhaust gas temperature improvements were demonstrated with the revised turbine in sea level and simulated altitude engine tests. Inspection of the revised seal hardware after these tests showed no unusual wear or degradation.

Top