Electromagnetic Radiation: Final Range Environmental Assessment, Revision 1
2009-12-03
scanning, research, and medical treatment and surgical procedures. There are many different types of lasing materials as identified below ( Indiana ...vapor (red) 0.627 Xenon chloride (Excimer-UV) 0.308 Helium neon (red) 0.633 Xenon fluoride (Excimer-UV) 0.351 Krypton (red) 0.647 Helium cadmium (UV...0.325 Rhodamine 6G dye (tunable) 0.570-0.650 Nitrogen (UV) 0.337 Ruby (CrAlO3) (red) 0.694 Helium cadmium (violet) 0.441 Gallium arsenide (diode
Applications of the 308-nm excimer laser in dermatology
NASA Astrophysics Data System (ADS)
Farkas, A.; Kemeny, L.
2006-05-01
Excimer lasers contain a mixture of a noble inert gas and a halogen, which form excited dimers only in the activated state. High-energy current is used to produce these dimers, which have a very short lifetime, and after their fast dissociation they release the excitation energy through ultraviolet photons. The application of these lasers proved to be successful in medicine, including the field of ophthalmology, cardiology, angiology, dentistry, orthopaedics, and, in recent years, dermatology. For medical purposes, the 193-nm argon fluoride, the 248-nm krypton fluoride, the 351-nm xenon fluoride, and the 308-nm xenon chloride lasers are used. Recently, the 308-nm xenon chloride laser has gained much attention as a very effective treatment modality in dermatological disorders. It was successfully utilized in psoriasis; later, it proved to be useful in handling other lightsensitive skin disorders and even in the treatment of allergic rhinitis. This review summarizes the possible applications of this promising tool in dermatology.
A purity monitor for the KEDR liquid krypton calorimeter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evtushenko, P. N.; Kotov, K. Yu.; Maslennikov, A. L.
We present a purity monitor for the KEDR liquid krypton calorimeter. A new method is suggested based on the usage of a short pulse of a gas discharge as a source of ultraviolet radiation for the photoproduction of electrons in a drift cell of the monitor. This paper describes the design of the monitor, the results of experiments with gaseous and liquid krypton, as well as the experience of using the developed device in the process of krypton purification for the KEDR liquid krypton calorimeter.
The VUV dimer spectra excited in condensed krypton
NASA Astrophysics Data System (ADS)
Gerasimov, Gennady N.; Krylov, Boris E.; Hallin, Reinhold
2004-05-01
The vacuum ultraviolet (VUV) emission spectra of krypton homonuclear molecules (dimers) were observed in the wavelength range 120-200 nm. The krypton dimers were excited in a DC capillary discharge and the wall of tube could be cooled with liquid nitrogen. The homogeneous DC discharge was a straight channel in the middle of capillary tube. The gas krypton pressure in the discharge channel could be stabilized in the pressure range from 3 hPa to 1000 hPa. The DC discharge current density and the electron concentration were ~ 10 A/cm2 and ~ 2-4 1014 cm-3, respectively. The VUV krypton spectra excited in vicinity of solid krypton were compared with the spectra recorded without condensed krypton. The VUV spectral lines intensities were observed as nonlinear function of the discharge length. This nonlinear increase of intensity with the length of the tube has still to be explained.
Energy of the quasi-free electron in supercritical krypton near the critical point.
Li, Luxi; Evans, C M; Findley, G L
2005-12-01
Field ionization measurements of high-n CH(3)I and C(2)H(5)I Rydberg states doped into krypton are presented as a function of krypton number density along the critical isotherm. These data exhibit a decrease in the krypton-induced shift of the dopant ionization energy near the critical point. This change in shift is modeled to within +/-0.2% of experiment using a theory that accounts for the polarization of krypton by the dopant ion, the polarization of krypton by the quasi-free electron that arises from field ionization of the dopant, and the zero point kinetic energy of the free electron. The overall decrease in the shift of the dopant ionization energy near the critical point of krypton, which is a factor of 2 larger than that observed in argon, is dominated by the increase in the zero point kinetic energy of the quasi-free electron.
Design documentation: Krypton encapsulation preconceptual design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knecht, D.A.
1994-10-01
US EPA regulations limit the release of Krypton-85 to the environment from commercial facilities after January 1, 1983. In order to comply with these regulations, Krypton-85, which would be released during reprocessing of commercial nuclear fuel, must be collected and stored. Technology currently exists for separation of krypton from other inert gases, and for its storage as a compressed gas in steel cylinders. The requirements, which would be imposed for 100-year storage of Krypton-85, have led to development of processes for encapsulation of krypton within a stable solid matrix. The objective of this effort was to provide preconceptual engineering designs,more » technical evaluations, and life cycle costing data for comparison of two alternate candidate processes for encapsulation of Krypton-85. This report has been prepared by The Ralph M. Parsons Company for the US Department of Energy.« less
Defects in ion-implanted hcp-titanium: A first-principles study of electronic structures
NASA Astrophysics Data System (ADS)
Raji, Abdulrafiu T.; Mazzarello, Riccardo; Scandolo, Sandro; Nsengiyumva, Schadrack; Härting, Margit; Britton, David T.
2011-12-01
The electronic structures of hexagonal closed-packed (h.c.p) titanium containing a vacancy and krypton impurity atoms at various insertion sites are calculated by first-principles methods in the framework of the density-functional theory (DFT). The density of states (DOS) for titanium containing a vacancy defect shows resonance-like features. Also, the bulk electron density decreases from ˜0.15/Å 3 to ˜0.05/Å 3 at the vacancy centre. Electronic structure calculations have been performed to investigate what underlies the krypton site preference in titanium. The DOS of the nearest-neighbour (NN) titanium atoms to the octahedral krypton appears to be less distorted (relative to pure titanium) when compared to the NN titanium atoms to the tetrahedral krypton. The electronic density deformation maps show that polarization of the titanium atoms is stronger when the krypton atom is located at the tetrahedral site. Since krypton is a closed-shell atom, thus precluding any bonding with the titanium atoms, we may conclude that the polarization of the electrons in the vicinity of the inserted krypton atoms and the distortion of the DOS of the NN titanium atoms to the krypton serve to indicate which defect site is preferred when a krypton atom is inserted into titanium. Based on these considerations, we conclude that the substitutional site is the most favourable one, and the octahedral is the preferred interstitial site, in agreement with recent DFT calculations of the energetics of krypton impurity sites.
The atmosphere of Mars: detection of krypton and xenon.
Owen, T; Biemann, K; Rushneck, D R; Biller, J E; Howarth, D W; Lafleur, A L
1976-12-11
Krypton and xenon have been discovered in the martian atmosphere with the mass spectrometer on the second Viking lander. Krypton is more abundant than xenon. The relative abundances of the krypton isotopes appear normal, but the ratio of xenon-129 to xenon-132 is enhanced on Mars relative to the terrestrial value for this ratio. Some possible implications of these findings are discussed.
An evaluation of krypton propellant in Hall thrusters
NASA Astrophysics Data System (ADS)
Linnell, Jesse Allen
Due to its high specific impulse and low price, krypton has long sparked interest as an alternate Hall thruster propellant. Unfortunately at the moment, krypton's relatively poor performance precludes it as a legitimate option. This thesis presents a detailed investigation into krypton operation in Hall thrusters. These findings suggest that the performance gap can be decreased to 4% and krypton can finally become a realistic propellant option. Although krypton has demonstrated superior specific impulse, the xenon-krypton absolute efficiency gap ranges between 2 and 15%. A phenomenological performance model indicates that the main contributors to the efficiency gap are propellant utilization and beam divergence. Propellant utilization and beam divergence have relative efficiency deficits of 5 and 8%, respectively. A detailed characterization of internal phenomena is conducted to better understand the xenon-krypton efficiency gap. Krypton's large beam divergence is found to be related to a defocusing equipotential structure and a weaker magnetic field topology. Ionization processes are shown to be linked to the Hall current, the magnetic mirror topology, and the perpendicular gradient of the magnetic field. Several thruster design and operational suggestions are made to optimize krypton efficiency. Krypton performance is optimized for discharge voltages above 500 V and flow rates corresponding to an a greater than 0.015 mg/(mm-s), where alpha is a function of flow rate and discharge channel dimensions (alpha = m˙alphab/Ach). Performance can be further improved by increasing channel length or decreasing channel width for a given flow rate. Also, several magnetic field design suggestions are made to enhance ionization and beam focusing. Several findings are presented that improve the understanding of general Hall thruster physics. Excellent agreement is shown between equipotential lines and magnetic field lines. The trim coil is shown to enhance beam focusing, ionization processes, and electron dynamics. Electron mobility and the Hall parameter are studied and compared to different mobility models. Azimuthal electron current is studied using a fluid and particle drift approach. Analyses of several magnetic field features are conducted and simple tools are suggested for the development of future Hall thrusters. These findings have strong implications for future Hall thruster design, lifetimes, and modeling.
Wagatsuma, Kazuaki
2009-04-01
The emission characteristics of ionic lines of nickel, cobalt, and vanadium were investigated when argon or krypton was employed as the plasma gas in glow discharge optical emission spectrometry. A dc Grimm-style lamp was employed as the excitation source. Detection limits of the ionic lines in each iron-matrix alloy sample were compared between the krypton and the argon plasmas. Particular intense ionic lines were observed in the emission spectra as a function of the discharge gas (krypton or argon), such as the Co II 258.033 nm for krypton and the Co II 231.707 nm for argon. The explanation for this is that collisions with the plasma gases dominantly populate particular excited levels of cobalt ion, which can receive the internal energy from each gas ion selectively, for example, the 3d(7)4p (3)G(5) (6.0201 eV) for krypton and the 3d(7)4p (3)G(4) (8.0779 eV) for argon. In the determination of nickel as well as cobalt in iron-matrix samples, more sensitive ionic lines could be found in the krypton plasma rather than the argon plasma. Detection limits in the krypton plasma were 0.0039 mass% Ni for the Ni II 230.299-nm line and 0.002 mass% Co for the Co II 258.033-nm line. However, in the determination of vanadium, the argon plasma had better analytical performance, giving a detection limit of 0.0023 mass% V for the V II 309.310-nm line.
Improved Multiple-Species Cyclotron Ion Source
NASA Technical Reports Server (NTRS)
Soli, George A.; Nichols, Donald K.
1990-01-01
Use of pure isotope 86Kr instead of natural krypton in multiple-species ion source enables source to produce krypton ions separated from argon ions by tuning cylcotron with which source used. Addition of capability to produce and separate krypton ions at kinetic energies of 150 to 400 MeV necessary for simulation of worst-case ions occurring in outer space.
Sheath oscillation characteristics and effect on near-wall conduction in a krypton Hall thruster
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Fengkui, E-mail: fengkuizhang@163.com; Kong, Lingyi; Li, Chenliang
2014-11-15
Despite its affordability, the krypton Hall-effect thruster in applications always had problems in regard to performance. The reason for this degradation is studied from the perspective of the near-wall conductivity of electrons. Using the particle-in-cell method, the sheath oscillation characteristics and its effect on near-wall conduction are compared in the krypton and xenon Hall-effect thrusters both with wall material composed of BNSiO{sub 2}. Comparing these two thrusters, the sheath in the krypton-plasma thruster will oscillate at low electron temperatures. The near-wall conduction current is only produced by collisions between electrons and wall, thereby causing a deficiency in the channel current.more » The sheath displays spatial oscillations only at high electron temperature; electrons are then reflected to produce the non-oscillation conduction current needed for the krypton-plasma thruster. However, it is accompanied with intensified oscillations.« less
NASA Astrophysics Data System (ADS)
Song, Bo; Waldrop, Jonathan M.; Wang, Xiaopo; Patkowski, Konrad
2018-01-01
We have developed a new krypton-krypton interaction-induced isotropic dipole polarizability curve based on high-level ab initio methods. The determination was carried out using the coupled-cluster singles and doubles plus perturbative triples method with very large basis sets up to augmented correlation-consistent sextuple zeta as well as the corrections for core-core and core-valence correlation and relativistic effects. The analytical function of polarizability and our recently constructed reference interatomic potential [J. M. Waldrop et al., J. Chem. Phys. 142, 204307 (2015)] were used to predict the thermophysical and electromagnetic properties of krypton gas. The second pressure, acoustic, and dielectric virial coefficients were computed for the temperature range of 116 K-5000 K using classical statistical mechanics supplemented with high-order quantum corrections. The virial coefficients calculated were compared with the generally less precise available experimental data as well as with values computed from other potentials in the literature {in particular, the recent highly accurate potential of Jäger et al. [J. Chem. Phys. 144, 114304 (2016)]}. The detailed examination in this work suggests that the present theoretical prediction can be applied as reference values in disciplines involving thermophysical and electromagnetic properties of krypton gas.
Multi-Column Xe/Kr Separation with AgZ-PAN and HZ-PAN
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greenhalgh, Mitchell Randy; Garn, Troy Gerry; Welty, Amy Keil
Previous multi-column xenon/krypton separation tests have demonstrated the capability of separating xenon from krypton in a mixed gas feed stream. The results of this initial testing with AgZ-PAN and HZ-PAN indicated that an excellent separation of xenon from krypton could be achieved. Building upon these initial results, a series of additional multi-column testing were performed in FY-16. The purpose of this testing was to scale up the sorbent beds, test a different composition of feed gas and attempt to improve the accuracy of the analysis of the individual capture columns’ compositions. Two Stirling coolers were installed in series to performmore » this testing. The use of the coolers instead of the cryostat provided two desired improvements, 1) removal of the large dilution due to the internal volume of the cryostat adsorption chamber, and 2) ability to increase the sorbent bed size for scale-up. The AgZ-PAN sorbent, due to its xenon selectivity, was loaded in the first column to capture the xenon while allowing the krypton to flow through and be routed to a second column containing the HZ-PAN for capture and analysis. The gases captured on both columns were sampled with evacuated sample bombs and subsequently analyzed via GC-MS for both krypton and xenon. The results of these tests can be used to develop the scope of future testing and analysis using this test bed for demonstrating the capture and separation of xenon and krypton using sorbents, for demonstrating desorption and regeneration of the sorbents, and for determining compositions of the desorbed gases. They indicate a need for future desorption studies in order to better quantify co-adsorbed species and final krypton purity.« less
A Performance Comparison of Xenon and Krypton Propellant on an SPT-100 Hall Thruster (Preprint)
2011-08-10
plume data from electrostatic probes. This paper presents the results of performance measurements made using an inverted pendulum thrust stand. Krypton...inverted pendulum thrust stand. Krypton operating conditions were tested over a large range of operating powers from 800 W to 3.9 kW. Analysis of how...advantages for missions where high thrust at reduced specific impulse is advantageous, primarily for orbit raising missions. Bismuth’s main drawback is
Krypton based adsorption type cryogenic refrigerator
NASA Technical Reports Server (NTRS)
Jones, Jack A. (Inventor); Schember, Helene R. (Inventor)
1989-01-01
Krypton and a monolithic porous carbon such as Saran carbon are used respectively as the sorbate and sorbent of an adsorption type refrigerator to improve refrigeration efficiency and operational longevity.
NASA Astrophysics Data System (ADS)
Dasgupta, Arati; Ouart, Nicholas; Giuiani, John; Clark, Robert; Schneider, Marilyn; Scott, Howard; Chen, Hui; Ma, Tammy
2017-10-01
X ray spectroscopy is used on the NIF to diagnose the plasma conditions in the ignition target in indirect drive ICF implosions. A platform is being developed at NIF where small traces of krypton are used as a dopant to the fuel gas for spectroscopic diagnostics using krypton line emissions. The fraction of krypton dopant was varied in the experiments and was selected so as not to perturb the implosion. Our goal is to use X-ray spectroscopy of dopant line ratios produced by the hot core that can provide a precise measurement of electron temperature. Simulations of the krypton spectra using a 1 in 104 atomic fraction of krypton in direct-drive exploding pusher with a range of electron temperatures and densities show discrepancies when different atomic models are used. We use our non-LTE atomic model with a detailed fine-structure level atomic structure and collisional-radiative rates to investigate the krypton spectra at the same conditions. Synthetic spectra are generated with a detailed multi-frequency radiation transport scheme from the emission regions of interest to analyze the experimental data with 0.02% Kr concentration and compare and contrast with the existing simulations at LLNL. Work supported by DOE/NNSA; Part of this work was also done under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract No. DE-AC52-07NA27344.
Kwok, Wai Him; Choi, Timmy L S; So, Pui-Kin; Yao, Zhong-Ping; Wan, Terence S M
2017-02-01
Xenon can activate the hypoxia-inducible factors (HIFs). As such, it has been allegedly used in human sports for increasing erythropoiesis. Krypton, another noble gas with reported narcosis effect, can also be expected to be a potential and less expensive erythropoiesis stimulating agent. This has raised concern about the misuse of noble gases as doping agents in equine sports. The aim of the present study is to establish a method for the simultaneous detection of xenon and krypton in equine plasma for the purpose of doping control. Xenon- or krypton-fortified equine plasma samples were prepared according to reported protocols. The target noble gases were simultaneously detected by gas chromatography-triple quadrupole mass spectrometry using headspace injection. Three xenon isotopes at m/z 129, 131, and 132, and four krypton isotopes at m/z 82, 83, 84, and 86 were targeted in selected reaction monitoring mode (with the precursor ions and product ions at identical mass settings), allowing unambiguous identification of the target analytes. Limits of detection for xenon and krypton were about 19 pmol/mL and 98 pmol/mL, respectively. Precision for both analytes was less than 15%. The method has good specificity as background analyte signals were not observed in negative equine plasma samples (n = 73). Loss of analytes under different storage temperatures has also been evaluated. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Ma, T.; Chen, H.; Patel, P. K.; ...
2016-08-18
The electron temperature at stagnation of an ICF implosion can be measured from the emission spectrum of high-energy x-rays that pass through the cold material surrounding the hot stagnating core. We describe a platform developed on the National Ignition Facility where trace levels of a mid-Z dopant (krypton) are added to the fuel gas of a symcap (symmetry surrogate) implosion to allow for the use of x-ray spectroscopy of the krypton line emission.Published by AIP Publishing
Ma, T; Chen, H; Patel, P K; Schneider, M B; Barrios, M A; Casey, D T; Chung, H-K; Hammel, B A; Berzak Hopkins, L F; Jarrott, L C; Khan, S F; Lahmann, B; Nora, R; Rosenberg, M J; Pak, A; Regan, S P; Scott, H A; Sio, H; Spears, B K; Weber, C R
2016-11-01
The electron temperature at stagnation of an ICF implosion can be measured from the emission spectrum of high-energy x-rays that pass through the cold material surrounding the hot stagnating core. Here we describe a platform developed on the National Ignition Facility where trace levels of a mid-Z dopant (krypton) are added to the fuel gas of a symcap (symmetry surrogate) implosion to allow for the use of x-ray spectroscopy of the krypton line emission.
NASA Astrophysics Data System (ADS)
Ma, T.; Chen, H.; Patel, P. K.; Schneider, M. B.; Barrios, M. A.; Casey, D. T.; Chung, H.-K.; Hammel, B. A.; Berzak Hopkins, L. F.; Jarrott, L. C.; Khan, S. F.; Lahmann, B.; Nora, R.; Rosenberg, M. J.; Pak, A.; Regan, S. P.; Scott, H. A.; Sio, H.; Spears, B. K.; Weber, C. R.
2016-11-01
The electron temperature at stagnation of an ICF implosion can be measured from the emission spectrum of high-energy x-rays that pass through the cold material surrounding the hot stagnating core. Here we describe a platform developed on the National Ignition Facility where trace levels of a mid-Z dopant (krypton) are added to the fuel gas of a symcap (symmetry surrogate) implosion to allow for the use of x-ray spectroscopy of the krypton line emission.
Mudgil, A V; To, K W; Balachandran, R M; Janigian, R H; Tsiaras, W G
1999-01-01
To determine the optimal wavelength for subconjunctival laser suture lysis. 130 black monofilament 10-0 nylon sutures were sewn subconjunctivally into the bare sclera of enucleated rabbit globes. The lowest energy levels facilitating laser suture lysis were determined for the argon green (514.5 NM), argon blue-green (488.0 NM, 514.5 NM), and krypton red (647.1 NM) wavelengths. In addition, absorption spectroscopy was performed on the suture material and conjunctiva using the Perkin Elmer W/VIS Lambda 2 spectrometer. Krypton red produced the fewest buttonhole defects, and it was also the most efficient energy source for suture lysis (P = 0.0001) under nontenectomized conjunctiva. Absorbance spectra studies revealed peak absorbance at 628 NM for the 10-0 nylon suture material. Based on animal and absorption spectroscopy studies, krypton red may be a safer and more efficient wavelength for subconjunctival laser suture lysis.
Isotopic Clues to Mars Crust-Atmosphere Interactions
2016-09-29
Chemistry that takes place in the surface material on Mars can explain why particular xenon (Xe) and krypton (Kr) isotopes are more abundant in the Martian atmosphere than expected. The isotopes -- variants that have different numbers of neutrons -- are formed in the loose rocks and material that make up the regolith -- the surface layer down to solid rock. The chemistry begins when cosmic rays penetrate into the surface material. If the cosmic rays strike an atom of barium (Ba), the barium can lose one or more of its neutrons (n0). Atoms of xenon can pick up some of those neutrons – a process called neutron capture – to form the isotopes xenon-124 and xenon-126. In the same way, atoms of bromine (Br) can lose some of their neutrons to krypton, leading to the formation of krypton-80 and krypton-82 isotopes. These isotopes can enter the atmosphere when the regolith is disturbed by impacts and abrasion, allowing gas to escape. http://photojournal.jpl.nasa.gov/catalog/PIA20847
Multi-Column Experimental Test Bed for Xe/Kr Separation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greenhalgh, Mitchell Randy; Garn, Troy Gerry; Welty, Amy Keil
Previous research studies have shown that INL-developed engineered form sorbents are capable of capturing both Kr and Xe from various composite gas streams. The previous experimental test bed provided single column testing for capacity evaluations over a broad temperature range. To advance research capabilities, the employment of an additional column to study selective capture of target species to provide a defined final gas composition for waste storage was warranted. The second column addition also allows for compositional analyses of the final gas product to provide for final storage determinations. The INL krypton capture system was modified by adding an additionalmore » adsorption column in order to create a multi-column test bed. The purpose of this modification was to investigate the separation of xenon from krypton supplied as a mixed gas feed. The extra column was placed in a Stirling Ultra-low Temperature Cooler, capable of controlling temperatures between 190 and 253K. Additional piping and valves were incorporated into the system to allow for a variety of flow path configurations. The new column was filled with the AgZ-PAN sorbent which was utilized as the capture medium for xenon while allowing the krypton to pass through. The xenon-free gas stream was then routed to the cryostat filled with the HZ-PAN sorbent to capture the krypton at 191K. Selectivities of xenon over krypton were determined using the new column to verify the system performance and to establish the operating conditions required for multi-column testing. Results of these evaluations verified that the system was operating as designed and also demonstrated that AgZ-PAN exhibits excellent selectivity for xenon over krypton in air at or near room temperature. Two separation tests were performed utilizing a feed gas consisting of 1000 ppmv xenon and 150 ppmv krypton with the balance being made up of air. The AgZ-PAN temperature was held at 295 or 253K while the HZ-PAN was held at 191K for both tests. The effluent from the AgZ-PAN column was monitored via GC-TCD during the tests with no xenon being observed exiting the column during either test. Samples from each column were taken via evacuated sample bombs and were analyzed by GC-MS analysis. The results demonstrated the ability to separate xenon from krypton from a mixed gas feed utilizing the new multi-column system.« less
In situ measurement of atmospheric krypton and xenon on Mars with Mars Science Laboratory
Conrad, P. G.; Malespin, C. A.; Franz, H. B.; ...
2016-11-01
Mars Science Laboratory's Sample Analysis at Mars (SAM) investigation has measured all of the stable isotopes of the heavy noble gases krypton and xenon in the martian atmosphere, in situ, from the Curiosity Rover at Gale Crater, Mars. Previous knowledge of martian atmospheric krypton and xenon isotope ratios has been based upon a combination of the Viking mission's krypton and xenon detections and measurements of noble gas isotope ratios in martian meteorites. But, the meteorite measurements reveal an impure mixture of atmospheric, mantle, and spallation contributions. The xenon and krypton isotopic measurements reported here include the complete set of stablemore » isotopes, unmeasured by Viking. Our new results generally agree with Mars meteorite measurements but also provide a unique opportunity to identify various non-atmospheric heavy noble gas components in the meteorites. Kr isotopic measurements define a solar-like atmospheric composition, but deviating from the solar wind pattern at 80Kr and 82Kr in a manner consistent with contributions originating from neutron capture in Br. The Xe measurements suggest an intriguing possibility that isotopes lighter than 132Xe have been enriched to varying degrees by spallation and neutron capture products degassed to the atmosphere from the regolith, and a model is constructed to explore this possibility. Such a spallation component, but, is not apparent in atmospheric Xe trapped in the glassy phases of martian meteorites.« less
In situ measurement of atmospheric krypton and xenon on Mars with Mars Science Laboratory
NASA Astrophysics Data System (ADS)
Conrad, P. G.; Malespin, C. A.; Franz, H. B.; Pepin, R. O.; Trainer, M. G.; Schwenzer, S. P.; Atreya, S. K.; Freissinet, C.; Jones, J. H.; Manning, H.; Owen, T.; Pavlov, A. A.; Wiens, R. C.; Wong, M. H.; Mahaffy, P. R.
2016-11-01
Mars Science Laboratory's Sample Analysis at Mars (SAM) investigation has measured all of the stable isotopes of the heavy noble gases krypton and xenon in the martian atmosphere, in situ, from the Curiosity Rover at Gale Crater, Mars. Previous knowledge of martian atmospheric krypton and xenon isotope ratios has been based upon a combination of the Viking mission's krypton and xenon detections and measurements of noble gas isotope ratios in martian meteorites. However, the meteorite measurements reveal an impure mixture of atmospheric, mantle, and spallation contributions. The xenon and krypton isotopic measurements reported here include the complete set of stable isotopes, unmeasured by Viking. The new results generally agree with Mars meteorite measurements but also provide a unique opportunity to identify various non-atmospheric heavy noble gas components in the meteorites. Kr isotopic measurements define a solar-like atmospheric composition, but deviating from the solar wind pattern at 80Kr and 82Kr in a manner consistent with contributions originating from neutron capture in Br. The Xe measurements suggest an intriguing possibility that isotopes lighter than 132Xe have been enriched to varying degrees by spallation and neutron capture products degassed to the atmosphere from the regolith, and a model is constructed to explore this possibility. Such a spallation component, however, is not apparent in atmospheric Xe trapped in the glassy phases of martian meteorites.
In Situ Measurement of Atmospheric Krypton and Xenon on Mars with Mars Science Laboratory
NASA Technical Reports Server (NTRS)
Conrad, P. G.; Malespin, C. A.; Franz, H. B.; Pepin, R. O.; Trainer, M. G.; Schwenzer, S. P.; Atreya, S. K.; Freissinet, C.; Jones, J. H.; Manning, H.;
2016-01-01
Mars Science Laboratorys Sample Analysis at Mars (SAM) investigation has measured all of the stable isotopes of the heavy noble gases krypton and xenon in the martian atmosphere, in situ, from the Curiosity Rover at Gale Crater, Mars. Previous knowledge of martian atmospheric krypton and xenon isotope ratios has been based upon a combination of the Viking missions krypton and xenon detections and measurements of noble gas isotope ratios in martian meteorites. However, the meteorite measurements reveal an impure mixture of atmospheric, mantle, and spallation contributions. The xenon and krypton isotopic measurements reported here include the complete set of stable isotopes, unmeasured by Viking. The new results generally agree with Mars meteorite measurements but also provide a unique opportunity to identify various non-atmospheric heavy noble gas components in the meteorites. Kr isotopic measurements define a solar-like atmospheric composition, but deviating from the solar wind pattern at 80Kr and 82Kr in a manner consistent with contributions originating from neutron capture in Br. The Xe measurements suggest an intriguing possibility that isotopes lighter than 132Xe have been enriched to varying degrees by spallation and neutron capture products degassed to the atmosphere from the regolith, and a model is constructed to explore this possibility. Such a spallation component, however, is not apparent in atmospheric Xe trapped in the glassy phases of martian meteorites.
In situ measurement of atmospheric krypton and xenon on Mars with Mars Science Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conrad, P. G.; Malespin, C. A.; Franz, H. B.
Mars Science Laboratory's Sample Analysis at Mars (SAM) investigation has measured all of the stable isotopes of the heavy noble gases krypton and xenon in the martian atmosphere, in situ, from the Curiosity Rover at Gale Crater, Mars. Previous knowledge of martian atmospheric krypton and xenon isotope ratios has been based upon a combination of the Viking mission's krypton and xenon detections and measurements of noble gas isotope ratios in martian meteorites. But, the meteorite measurements reveal an impure mixture of atmospheric, mantle, and spallation contributions. The xenon and krypton isotopic measurements reported here include the complete set of stablemore » isotopes, unmeasured by Viking. Our new results generally agree with Mars meteorite measurements but also provide a unique opportunity to identify various non-atmospheric heavy noble gas components in the meteorites. Kr isotopic measurements define a solar-like atmospheric composition, but deviating from the solar wind pattern at 80Kr and 82Kr in a manner consistent with contributions originating from neutron capture in Br. The Xe measurements suggest an intriguing possibility that isotopes lighter than 132Xe have been enriched to varying degrees by spallation and neutron capture products degassed to the atmosphere from the regolith, and a model is constructed to explore this possibility. Such a spallation component, but, is not apparent in atmospheric Xe trapped in the glassy phases of martian meteorites.« less
Code of Federal Regulations, 2010 CFR
2010-01-01
... promethium-147: Requirements for license to manufacture, process, produce, or initially transfer. 32.22 Section 32.22 Energy NUCLEAR REGULATORY COMMISSION SPECIFIC DOMESTIC LICENSES TO MANUFACTURE OR TRANSFER... containing tritium, krypton-85 or promethium-147: Requirements for license to manufacture, process, produce...
NASA Technical Reports Server (NTRS)
Laue, H. H.; Clough, L. G. (Inventor)
1973-01-01
An electrodeless lamp circuit with a coil surrounding a krypton lamp is driven by an RF input source. A coil surrounding a mercury lamp is tapped across the connection of the input central to the krypton-lamp coil. Each coil is connected in parallel with separate capacitors which form resonant circuits at the input frequency.
Separation and purification of xenon
Schlea, deceased, Carl Solomon
1978-03-14
Xenon is separated from a mixture of xenon and krypton by extractive distillation using carbon tetrafluoride as the partitioning agent. Krypton is flushed out of the distillation column with CF.sub.4 in the gaseous overhead stream while purified xenon is recovered from the liquid bottoms. The distillation is conducted at about atmospheric pressure or at subatmospheric pressure.
Garn, Troy G.; Greenhalgh, Mitchell; Law, Jack D.
2015-12-22
A new engineered form composite sorbent for the selective separation of xenon from krypton in simulant composition off-gas streams resulting from the reprocessing of used nuclear fuel has been developed and evaluated. A sodium mordenite powder was incorporated into a macroporous polymer binder, formed into spherical beads and successfully converted to a 9 wt.% silver form composite sorbent. The final engineered form sorbent retained the characteristic surface area indicative of sodium mordenite powder. The sorbent was evaluated for xenon adsorption potential with capacities measured as high as 30 millimoles of xenon per kilogram of sorbent achieved at ambient temperature andmore » 460 millimoles of xenon per kilogram sorbent at 220 K. Xenon/krypton selectivity was calculated to be 22.4 with a 1020 µL/L xenon, 150 µL/L krypton in a balance of air feed gas at 220 K. Furthermore, adsorption/desorption thermal cycling effects were evaluated with results indicating sorbent performance was not significantly impacted while undergoing numerous adsorption/desorption thermal cycles.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosendahl, S., E-mail: rosendahl@wwu.de; Brown, E.; Fieguth, A.
The separation of krypton and xenon is of particular importance for the field of direct dark matter search with liquid xenon detectors. The intrinsic contamination of the xenon with radioactive {sup 85}Kr makes a significant background for these kinds of low count-rate experiments and has to be removed beforehand. This can be achieved by cryogenic distillation, a technique widely used in industry, using the different vapor pressures of krypton and xenon. In this paper, we present an investigation on the separation performance of a single stage distillation system using a radioactive {sup 83m}Kr-tracer method. The separation characteristics under different operationmore » conditions are determined for very low concentrations of krypton in xenon at the level of {sup 83m}Kr/Xe = 1.9 ⋅ 10{sup −15}, demonstrating, that cryogenic distillation in this regime is working. The observed separation is in agreement with the expectation from the different volatilities of krypton and xenon. This cryogenic distillation station is the first step on the way to a multi-stage cryogenic distillation column for the next generation of direct dark matter experiment XENON1T.« less
New method of 85Kr reduction in a noble gas based low-background detector
NASA Astrophysics Data System (ADS)
Akimov, D. Yu.; Bolozdynya, A. I.; Burenkov, A. A.; Hall, C.; Kovalenko, A. G.; Kuzminov, V. V.; Simakov, G. E.
2017-04-01
Krypton-85 is an anthropogenic beta-decaying isotope which produces low energy backgrounds in dark matter and neutrino experiments, especially those based upon liquid xenon. Several technologies have been developed to reduce the Kr concentration in such experiments. We propose to augment those separation technologies by first adding to the xenon an 85Kr-free sample of krypton in an amount much larger than the natural krypton that is already present. After the purification system reduces the total Kr concentration to the same level, the final 85Kr concentration will be reduced even further by the dilution factor. A test cell for measurement of the activity of various Kr samples has been assembled, and the activity of 25-year-old krypton has been measured. The measured activity agrees well with the expected activity accounting for the 85Kr abundance of the earth's atmosphere in 1990 and the half-life of the isotope. Additional tests with a Kr sample produced in the year 1944 (before the atomic era) have been done in order to demonstrate the sensitivity of the test cell.
A 205 Hour Krypton Propellant Life Test of the SPT-100 Operating at 3 kW
2013-09-01
advantageous, such as orbit raising missions. Bismuth’s main drawback is that the metal must be vaporized to be ionized and accelerated within a Hall...the performance of the SPT-100 operating on krypton was characterized using an inverted pendulum thrust stand over a wide range of thruster operating
The refractive index of krypton for lambda in the closed interval 168-288 nm
NASA Technical Reports Server (NTRS)
Smith, P. L.; Parkinson, W. H.; Huber, M. C. E.
1975-01-01
The index of refraction of krypton has been measured at 27 wavelengths between and including 168 and 288 nm. The probable error of each measurement is plus or minus 0.1%. Our results are compared with other measurements. Our data are about 3.8% smaller than those of Abjean et al.
Numerical simulations of gas mixing effect in electron cyclotron resonance ion sources
NASA Astrophysics Data System (ADS)
Mironov, V.; Bogomolov, S.; Bondarchenko, A.; Efremov, A.; Loginov, V.
2017-01-01
The particle-in-cell Monte Carlo collisions code nam-ecris is used to simulate the electron cyclotron resonance ion source (ECRIS) plasma sustained in a mixture of Kr with O2 , N2 , Ar, Ne, and He. The model assumes that ions are electrostatically confined in the ECR zone by a dip in the plasma potential. A gain in the extracted krypton ion currents is seen for the highest charge states; the gain is maximized when oxygen is used as a mixing gas. The special feature of oxygen is that most of the singly charged oxygen ions are produced after the dissociative ionization of oxygen molecules with a large kinetic energy release of around 5 eV per ion. The increased loss rate of energetic lowly charged ions of the mixing element requires a building up of the retarding potential barrier close to the ECR surface to equilibrate electron and ion losses out of the plasma. In the mixed plasmas, the barrier value is large (˜1 V ) compared to pure Kr plasma (˜0.01 V ), with longer confinement times of krypton ions and with much higher ion temperatures. The temperature of the krypton ions is increased because of extra heating by the energetic oxygen ions and a longer time of ion confinement. In calculations, a drop of the highly charged ion currents of lighter elements is observed when adding small fluxes of krypton into the source. This drop is caused by the accumulation of the krypton ions inside plasma, which decreases the electron and ion confinement times.
Thermophysical properties of krypton-helium gas mixtures from ab initio pair potentials
2017-01-01
A new potential energy curve for the krypton-helium atom pair was developed using supermolecular ab initio computations for 34 interatomic distances. Values for the interaction energies at the complete basis set limit were obtained from calculations with the coupled-cluster method with single, double, and perturbative triple excitations and correlation consistent basis sets up to sextuple-zeta quality augmented with mid-bond functions. Higher-order coupled-cluster excitations up to the full quadruple level were accounted for in a scheme of successive correction terms. Core-core and core-valence correlation effects were included. Relativistic corrections were considered not only at the scalar relativistic level but also using full four-component Dirac–Coulomb and Dirac–Coulomb–Gaunt calculations. The fitted analytical pair potential function is characterized by a well depth of 31.42 K with an estimated standard uncertainty of 0.08 K. Statistical thermodynamics was applied to compute the krypton-helium cross second virial coefficients. The results show a very good agreement with the best experimental data. Kinetic theory calculations based on classical and quantum-mechanical approaches for the underlying collision dynamics were utilized to compute the transport properties of krypton-helium mixtures in the dilute-gas limit for a large temperature range. The results were analyzed with respect to the orders of approximation of kinetic theory and compared with experimental data. Especially the data for the binary diffusion coefficient confirm the predictive quality of the new potential. Furthermore, inconsistencies between two empirical pair potential functions for the krypton-helium system from the literature could be resolved. PMID:28595411
Thermophysical properties of krypton-helium gas mixtures from ab initio pair potentials
NASA Astrophysics Data System (ADS)
Jäger, Benjamin; Bich, Eckard
2017-06-01
A new potential energy curve for the krypton-helium atom pair was developed using supermolecular ab initio computations for 34 interatomic distances. Values for the interaction energies at the complete basis set limit were obtained from calculations with the coupled-cluster method with single, double, and perturbative triple excitations and correlation consistent basis sets up to sextuple-zeta quality augmented with mid-bond functions. Higher-order coupled-cluster excitations up to the full quadruple level were accounted for in a scheme of successive correction terms. Core-core and core-valence correlation effects were included. Relativistic corrections were considered not only at the scalar relativistic level but also using full four-component Dirac-Coulomb and Dirac-Coulomb-Gaunt calculations. The fitted analytical pair potential function is characterized by a well depth of 31.42 K with an estimated standard uncertainty of 0.08 K. Statistical thermodynamics was applied to compute the krypton-helium cross second virial coefficients. The results show a very good agreement with the best experimental data. Kinetic theory calculations based on classical and quantum-mechanical approaches for the underlying collision dynamics were utilized to compute the transport properties of krypton-helium mixtures in the dilute-gas limit for a large temperature range. The results were analyzed with respect to the orders of approximation of kinetic theory and compared with experimental data. Especially the data for the binary diffusion coefficient confirm the predictive quality of the new potential. Furthermore, inconsistencies between two empirical pair potential functions for the krypton-helium system from the literature could be resolved.
High-Power Krypton Hall Thruster Technology Being Developed for Nuclear-Powered Applications
NASA Technical Reports Server (NTRS)
Jacobson, David T.; Manzella, David H.
2004-01-01
The NASA Glenn Research Center has been performing research and development of moderate specific impulse, xenon-fueled, high-power Hall thrusters for potential solar electric propulsion applications. These applications include Mars missions, reusable tugs for low-Earth-orbit to geosynchronous-Earth-orbit transportation, and missions that require transportation to libration points. This research and development effort resulted in the design and fabrication of the NASA-457M Hall thruster that has been tested at input powers up to 95 kW. During project year 2003, NASA established Project Prometheus to develop technology in the areas of nuclear power and propulsion, which are enabling for deep-space science missions. One of the Project-Prometheus-sponsored Nuclear Propulsion Research tasks is to investigate alternate propellants for high-power Hall thruster electric propulsion. The motivation for alternate propellants includes the disadvantageous cost and availability of xenon propellant for extremely large scale, xenon-fueled propulsion systems and the potential system performance benefits of using alternate propellants. The alternate propellant krypton was investigated because of its low cost relative to xenon. Krypton propellant also has potential performance benefits for deep-space missions because the theoretical specific impulse for a given voltage is 20 percent higher than for xenon because of krypton's lower molecular weight. During project year 2003, the performance of the high-power NASA-457M Hall thruster was measured using krypton as the propellant at power levels ranging from 6.4 to 72.5 kW. The thrust produced ranged from 0.3 to 2.5 N at a discharge specific impulse up to 4500 sec.
Use of krypton laser stimulation in the treatment of dry eye syndrome
NASA Astrophysics Data System (ADS)
Kecik, Tadeusz; Switka-Wieclawska, Iwona; Ciszewska, Joanna; Portacha, Lidia
1991-08-01
We''d like to present the use of krypton laser stimulation in the treatment of dry eye syndrom. 10 patients with dry eye syndrom were treated with irradiation of the lacrimal gland. Schirmer test and break up time were performed before and after therapy. After 10 days of treatment we observed higher value of secreted tear amount.
Numerical study of influence of hydrogen backflow on krypton Hall effect thruster plasma focusing
NASA Astrophysics Data System (ADS)
Yan, Shilin; Ding, Yongjie; Wei, Liqiu; Hu, Yanlin; Li, Jie; Ning, Zhongxi; Yu, Daren
2017-03-01
The influence of backflow hydrogen on plasma plume focusing of a krypton Hall effect thruster is studied via a numerical simulation method. Theoretical analysis indicates that hydrogen participates in the plasma discharge process, changes the potential and ionization distribution in the thruster discharge cavity, and finally affects the plume focusing within a vacuum vessel.
Toward compact and ultra-intense laser-based soft x-ray lasers
NASA Astrophysics Data System (ADS)
Sebban, S.; Depresseux, A.; Oliva, E.; Gautier, J.; Tissandier, F.; Nejdl, J.; Kozlova, M.; Maynard, G.; Goddet, J. P.; Tafzi, A.; Lifschitz, A.; Kim, H. T.; Jacquemot, S.; Rousseau, P.; Zeitoun, P.; Rousse, A.
2018-01-01
We report here recent work on an optical field ionized (OFI), high-order harmonic-seeded EUV laser. The amplifying medium is a plasma of nickel-like krypton obtained by OFI when focusing a 1 J, 30 fs, circularly-polarized, infrared pulse into a krypton-filled gas cell or krypton gas jet. The lasing transition is the 3d94d (J = 0) → 3d94p (J = 1) transition of Ni-like krypton ions at 32.8 nm and is pumped by collisions with hot electrons. The gain dynamics was probed by seeding the amplifier with a high-order harmonic pulse at different delays. The gain duration monotonically decreased from 7 ps to an unprecedented shortness of 450 fs full width at half-maximum as the amplification peak rose from 150 to 1200 with an increase of the plasma density from 3 × 1018 to 1.2 × 1020 cm-3. The integrated energy of the EUV laser pulse was also measured, and found to be around 2 μJ. It is to be noted that in the ASE mode, longer amplifiers were achieved (up to 2 cm), yielding EUV outputs up to 14 μJ.
Krypton adsorption on rutile: State and cross-sectional area at 77 K
NASA Astrophysics Data System (ADS)
Grillet, Y.; Rouquerol, F.; Rouquerol, J.
1985-10-01
A krypton adsorption study was carried out on a polycrystalline TiO 2 sample (98.5% rutile) presently considered as a potential reference material for surface areas. Both adsorption microcalorimetry and volumetry show evidence of a two-dimensional phase change (from 2D fluid to 2D solid) taking place at 77 K before the completion of the monolayer. No such phenomenon is observed neither with nitrogen (which we explain by a strong orientation and a close-packing of this molecule on a polar surface) neither with argon (which we explain by a large incompatibility factor between rutile and an argon crystal). On completion of the monolayer, the krypton molecular cross-sectional area is here around 0.15 nm 2 (instead of the usual 0.17 to 0.21 nm 2).
Blankenship, G W
1986-01-01
The effects of PRP with red krypton laser are essentially identical to those produced with blue-green argon laser. Burns of the rabbit retina produced with these two different lasers are almost the same. In a prospective and randomized clinical trial of proliferative diabetic retinopathy treatment there was no significant difference between PRP using these two different lasers. The characteristic changes of rabbit fundi 3, 7, and 30 days after PRP with red krypton laser were almost the same as those following blue-green argon laser. Both types of treatment frequently produced small vitreous hemorrhages and exudative retinal detachments, but choroidal thickening occurred more frequently with argon treatment. These changes were transient and had resolved within 30 days of treatment. The microscopic changes consisted of pigment epithelial disruption with pigment migration into the retina, heat coagulation of the photoreceptors, disruption of the outer and inner nuclear layers with atrophy of the nuclei, and temporary swelling of the nerve fiber layer. The untreated retina and choroid between burns was not involved and appeared normal at each period. Thirty days after treatment, the scarring produced by these two types of burns was identical. Seventy-one eyes with proliferative diabetic retinopathy having three or four retinopathy risk factors were treated with panretinal laser photocoagulation, and followed in a prospective study for 6 months. Thirty-six eyes were randomly selected for blue-green argon treatment, and 35 were randomly selected for red krypton treatment. The incidence of undesired side effects during the first 2 weeks following treatment was almost identical between the two groups. However, by 1 month the majority of eyes in both groups had visual acuities equal to or better than the pretreatment acuities and complete regression of NVD. Six months after treatment, the majority of eyes in both groups continued to have visual acuities equal to or better than the pretreatment acuities with fewer cases having larger losses of vision in the krypton treated group. Loss of peripheral visual field was equal with the two types of treatment having a minimal decrease with the IV-4e isopter, but substantial loss with the I-4e isopter. Additional vitreous hemorrhage rarely occurred in either group, but was slightly more frequent in those treated with krypton. Complete regression was accomplished in most eyes with pretreatment disc and/or NVE in both groups, but persistence of neovascularization was more frequent in those treated with krypton. Overall, the wavelength used seemingly had little effect on the result.(ABSTRACT TRUNCATED AT 400 WORDS)
Multi-component testing using HZ-PAN and AgZ-PAN Sorbents for OSPREY Model validation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garn, Troy G.; Greenhalgh, Mitchell; Lyon, Kevin L.
2015-04-01
In efforts to further develop the capability of the Off-gas SeParation and RecoverY (OSPREY) model, multi-component tests were completed using both HZ-PAN and AgZ-PAN sorbents. The primary purpose of this effort was to obtain multi-component xenon and krypton capacities for comparison to future OSPREY predicted multi-component capacities using previously acquired Langmuir equilibrium parameters determined from single component isotherms. Experimental capacities were determined for each sorbent using two feed gas compositions of 1000 ppmv xenon and 150 ppmv krypton in either a helium or air balance. Test temperatures were consistently held at 220 K and the gas flowrate was 50 sccm.more » Capacities were calculated from breakthrough curves using TableCurve® 2D software by Jandel Scientific. The HZ-PAN sorbent was tested in the custom designed cryostat while the AgZ-PAN was tested in a newly installed cooling apparatus. Previous modeling validation efforts indicated the OSPREY model can be used to effectively predict single component xenon and krypton capacities for both engineered form sorbents. Results indicated good agreement with the experimental and predicted capacity values for both krypton and xenon on the sorbents. Overall, the model predicted slightly elevated capacities for both gases which can be partially attributed to the estimation of the parameters and the uncertainty associated with the experimental measurements. Currently, OSPREY is configured such that one species adsorbs and one does not (i.e. krypton in helium). Modification of OSPREY code is currently being performed to incorporate multiple adsorbing species and non-ideal interactions of gas phase species with the sorbent and adsorbed phases. Once these modifications are complete, the sorbent capacities determined in the present work will be used to validate OSPREY multicomponent adsorption predictions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Visser, Ate; Bibby, Richard K.; Moran, Jean E.
A capability for the analysis of krypton-85 ( 85Kr) in groundwater samples was developed at LLNL. Samples are collected by extracting gas from 2000-4000 L of groundwater at the well, yielding approximately 0.2 cm 3 STP krypton. Sample collection takes 1 to 4 hours. Krypton is purified in the laboratory using a combination of molecular sieve and activated charcoal traps, and transferred to a liquid scintillation vial. The 85Kr activity is measured by liquid scintillation on a Quantulus 1220 liquid scintillation counter from PerkinElmer. The detection limit for a typical 0.2 cm 3Kr sample size is 11% of the presentmore » day activity in air, corresponding to the decay corrected activity in air in 1987. The typical measurement uncertainty is below 10% for recently recharged samples. Six groundwater samples were collected, purified and counted. 85Kr was not detected in any of the samples counted at LLNL. 85Kr was detected by the low level counting laboratory of Bern University in all samples between 1.5 and 6.6 decays per minute per cm 3 krypton, corresponding to decay corrected activities in air between 1971 and 1985. The new capability is an excellent complement to tritium-helium, expanding the existing suite of age dating tools available to the GAMA program ( 35S, 3H/ 3He, 14C and radiogenic helium). 85Kr can replace 3H/ 3He in settings where 3H/ 3He ages are impossible to determine (for example where terrigenic helium overwhelms tritiogenic helium) and provides additional insight into travel time distributions in complex mixed groundwater systems.« less
Volumetric direct nuclear pumped laser
NASA Technical Reports Server (NTRS)
Jalufka, N. W.; Hohl, F.; Deyoung, R. J.; Williams, M. D. (Inventor)
1978-01-01
A volumetric direct nuclear pumped laser was developed in which the gas is a mixture of He-3 and a minority gas from the group of argon, krypton, xenon, chlorine and fluorine. The mixture of He-3 and the minority gas produces lasing with a minority gas concentration of from 0.01 to 10 percent argon, 1 percent krypton, 0.01 to 5 percent xenon and small concentrations of chlorine or fluorine.
Xenon Fractionation and Archean Hydrogen Escape
NASA Technical Reports Server (NTRS)
Zahnle, K. J.
2015-01-01
Xenon is the heaviest gas found in significant quantities in natural planetary atmospheres. It would seem the least likely to escape. Yet there is more evidence for xenon escape from Earth than for any element other than helium and perhaps neon. The most straightforward evidence is that most of the radiogenic Xe from the decay of (129)I (half-life 15.7 Myr) and (244)Pu (half-life 81 Myr) that is Earth's birthright is missing. The missing xenon is often attributed to the impact erosion of early atmospheres of Earth and its ancestors. It is obvious that if most of the radiogenic xenon were driven off by impacts, most of the rest of the atmophiles fared the same fate. The other line of evidence is in the nonradiogenic isotopes of xenon and its silent partner, krypton. Atmospheric xenon is strongly mass fractionated (at about 4% per amu) compared to any known solar system source (Figure 1). This is in stark contrast to krypton, which may not be fractionated at all: atmospheric Kr is slightly heavier than solar Kr (at about 0.5% per amu), but it is the same as in carbonaceous chondrites. Nonradiogenic xenon is also under abundant relative to krypton (the so-called "missing xenon" problem). Together these observations imply that xenon has been subject to fractionating escape and krypton not.
Method for treating a nuclear process off-gas stream
Pence, Dallas T.; Chou, Chun-Chao
1984-01-01
Disclosed is a method for selectively removing and recovering the noble gas and other gaseous components typically emitted during nuclear process operations. The method is adaptable and useful for treating dissolver off-gas effluents released during reprocessing of spent nuclear fuels whereby to permit radioactive contaminant recovery prior to releasing the remaining off-gases to the atmosphere. Briefly, the method sequentially comprises treating the off-gas stream to preliminarily remove NO.sub.x, hydrogen and carbon-containing organic compounds, and semivolatile fission product metal oxide components therefrom; adsorbing iodine components on silver-exchanged mordenite; removing water vapor carried by said stream by means of a molecular sieve; selectively removing the carbon dioxide components of said off-gas stream by means of a molecular sieve; selectively removing xenon in gas phase by passing said stream through a molecular sieve comprising silver-exchanged mordenite; selectively separating krypton from oxygen by means of a molecular sieve comprising silver-exchanged mordenite; selectively separating krypton from the bulk nitrogen stream using a molecular sieve comprising silver-exchanged mordenite cooled to about -140.degree. to -160.degree. C.; concentrating the desorbed krypton upon a molecular sieve comprising silver-exchange mordenite cooled to about -140.degree. to -160.degree. C.; and further cryogenically concentrating, and the recovering for storage, the desorbed krypton.
The vacuum ultraviolet spectrum of krypton and xenon excimers excited in a cooled dc discharge
NASA Astrophysics Data System (ADS)
Gerasimov, G.; Krylov, B.; Loginov, A.; Zvereva, G.; Hallin, R.; Arnesen, A.; Heijkenskjöld, F.
1998-01-01
We present results of an experimental and theoretical study of the VUV spectra of krypton and xenon excimers excited by a dc discharge in a capillary tube cooled by liquid nitrogen. The studied spectral regions of 115-170 nm and 140-195 nm for krypton and xenon respectively correspond to transitions between the lowest excited dimer states 1u, 0u+ and the weakly bound ground state 0g+. A semiempirical method was suggested and applied to describe the experimental spectra and to estimate the temperature of the radiating plasma volume. Electron impact, transferring dimers from the ground state to the excited states, is shown to be an efficient excitation mechanism in the 100-850 hPa and the 10-50 mA pressure and discharge current ranges. The spectra obtained as well as the results of calculations corroborate the high rate of this mechanism.
Mattsson, Thomas R.; Root, Seth; Mattsson, Ann E.; ...
2014-11-11
We use Sandia's Z machine and magnetically accelerated flyer plates to shock compress liquid krypton to 850 GPa and compare with results from density-functional theory (DFT) based simulations using the AM05 functional. We also employ quantum Monte Carlo calculations to motivate the choice of AM05. We conclude that the DFT results are sensitive to the quality of the pseudopotential in terms of scattering properties at high energy/temperature. A new Kr projector augmented wave potential was constructed with improved scattering properties which resulted in excellent agreement with the experimental results to 850 GPa and temperatures above 10 eV (110 kK). Inmore » conclusion, we present comparisons of our data from the Z experiments and DFT calculations to current equation of state models of krypton to determine the best model for high energy-density applications.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jäger, Benjamin, E-mail: benjamin.jaeger@uni-rostock.de; Hellmann, Robert, E-mail: robert.hellmann@uni-rostock.de; Bich, Eckard
2016-03-21
A new reference krypton-krypton interatomic potential energy curve was developed by means of quantum-chemical ab initio calculations for 36 interatomic separations. Highly accurate values for the interaction energies at the complete basis set limit were obtained using the coupled-cluster method with single, double, and perturbative triple excitations as well as t-aug-cc-pV5Z and t-aug-cc-pV6Z basis sets including mid-bond functions, with the 6Z basis set being newly constructed for this study. Higher orders of coupled-cluster terms were considered in a successive scheme up to full quadruple excitations. Core-core and core-valence correlation effects were included. Furthermore, relativistic effects were studied not only atmore » a scalar relativistic level using second-order direct perturbation theory, but also utilizing full four-component and Gaunt-effect computations. An analytical pair potential function was fitted to the interaction energies, which is characterized by a depth of 200.88 K with an estimated standard uncertainty of 0.51 K. Thermophysical properties of low-density krypton were calculated for temperatures up to 5000 K. Second and third virial coefficients were obtained from statistical thermodynamics. Viscosity and thermal conductivity as well as the self-diffusion coefficient were computed using the kinetic theory of gases. The theoretical results are compared with experimental data and with results for other pair potential functions from the literature, especially with those calculated from the recently developed ab initio potential of Waldrop et al. [J. Chem. Phys. 142, 204307 (2015)]. Highly accurate experimental viscosity data indicate that both the present ab initio pair potential and the one of Waldrop et al. can be regarded as reference potentials, even though the quantum-chemical methods and basis sets differ. However, the uncertainties of the present potential and of the derived properties are estimated to be considerably lower.« less
Analysis of violet-excited fluorochromes by flow cytometry using a violet laser diode.
Telford, William G; Hawley, Teresa S; Hawley, Robert G
2003-07-01
Low power violet laser diodes (VLDs) have been evaluated as potential replacements for water-cooled argon-ion and krypton-ion ultraviolet and violet lasers for DNA content analysis using the Hoechst dyes and 4,6-diamidino-2-phenylindole (Shapiro HMN, Perlmutter NG: Cytometry 44:133-136, 2001). In this study, we used a VLD to excite a variety of violet-excited fluorescent molecules important in biomedical analysis, including the fluorochromes Cascade Blue and Pacific Blue, the expressible fluorescent protein cyan fluorescent protein (CFP), and the fluorogenic alkaline phosphatase (AP) substrate 2-(5'-chloro-2'-phosphoryloxyphenyl)-6-chloro-4-(3H)-quinazoline (ELF-97; for endogenous AP detection and cell surface labeling with AP-conjugated antibodies). Comparisons were made between VLD excitation and a krypton-ion laser emitting at 407 nm (both at higher power levels and with the beam attenuated at levels approximating the VLD) on the same FACSVantage SE stream-in-air flow cytometer. We evaluated a Power Technology 408-nm VLD (30 mW) equipped with circularization optics (18 mW maximum output, set to 15 mW) and a Coherent I-302C krypton-ion laser emitting at power levels ranging from 15 to 75 mW. Cascade Blue, Pacific Blue, and CFP showed comparable signal-to-noise ratios and levels of sensitivity with VLD excitation versus the krypton-ion laser at high and VLD-matched power outputs. Multicolor fluorescent protein analysis with 488-nm excitation of green fluorescent protein and DsRed and VLD excitation of CFP was therefore feasible and was demonstrated. Similar levels of excitation efficiency between krypton-ion and VLD sources also were observed for ELF-97 detection. These evaluations confirmed that VLDs may be cost- and maintenance-effective replacements for water-cooled gas lasers for applications requiring violet excitation in addition to DNA binding dyes. Published 2003 Wiley-Liss, Inc.
Jäger, Benjamin; Hellmann, Robert; Bich, Eckard; Vogel, Eckhard
2016-03-21
A new reference krypton-krypton interatomic potential energy curve was developed by means of quantum-chemical ab initio calculations for 36 interatomic separations. Highly accurate values for the interaction energies at the complete basis set limit were obtained using the coupled-cluster method with single, double, and perturbative triple excitations as well as t-aug-cc-pV5Z and t-aug-cc-pV6Z basis sets including mid-bond functions, with the 6Z basis set being newly constructed for this study. Higher orders of coupled-cluster terms were considered in a successive scheme up to full quadruple excitations. Core-core and core-valence correlation effects were included. Furthermore, relativistic effects were studied not only at a scalar relativistic level using second-order direct perturbation theory, but also utilizing full four-component and Gaunt-effect computations. An analytical pair potential function was fitted to the interaction energies, which is characterized by a depth of 200.88 K with an estimated standard uncertainty of 0.51 K. Thermophysical properties of low-density krypton were calculated for temperatures up to 5000 K. Second and third virial coefficients were obtained from statistical thermodynamics. Viscosity and thermal conductivity as well as the self-diffusion coefficient were computed using the kinetic theory of gases. The theoretical results are compared with experimental data and with results for other pair potential functions from the literature, especially with those calculated from the recently developed ab initio potential of Waldrop et al. [J. Chem. Phys. 142, 204307 (2015)]. Highly accurate experimental viscosity data indicate that both the present ab initio pair potential and the one of Waldrop et al. can be regarded as reference potentials, even though the quantum-chemical methods and basis sets differ. However, the uncertainties of the present potential and of the derived properties are estimated to be considerably lower.
Ion Deposited Carbon Coatings.
1983-07-01
levels correspondant i la transition entre les nivellux 2 piao and 5 d, of the kr-ypton-86 atom. 2 p,,, et 5 d5, de l’atow~e krypton 86. kilogram (kg...6gal A la [Mafsse (II prototype inItern ational du the kilogram. (The international prototype of kilogrananric. the kilogram is at particular cylinder...seconde (s) The second is the duration of 9 192 631 770 La seconde est IaI dur&e de 9 192 63 1 770 periods of the radiation corresponding to the perioiles
NASA Technical Reports Server (NTRS)
Soli, George A.; Nichols, Donald K.
1989-01-01
An isotope of krypton, Kr86, has been combined with a mix of Ar, Ne, and N ions at the electron cyclotron resonance (ECR) source, at the Lawrence Berkeley Laboratory cyclotron, to provide rapid ion changeover in Single Event Phenomena (SEP) testing. The new technique has been proved out successfully by a recent Jet Propulsion Laboratory (JPL) test in which it was found that there was no measurable contamination from other isotopes.
Comparison of Medium Power Hall Effect Thruster Ion Acceleration for Krypton and Xenon Propellants
2016-09-14
Concentration ppb 87 1000 Stable Isotopes 9 6 Odd Isotopes 2 1 Critical Pressure MPa 5.84 5.50 Critical Temperature K 290 209 Boiling Point (1 atm) K 161 120...The velocity profile in Fig. 6 shows the velocities slightly negative, nearest the anode (at approximately - 9 mm). This negative velocity near the...Krypton and Xenon Propellants 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6 . AUTHOR(S) William A. Hargus, Jr.; Gregory M. Azarnia; Michael R
A Distant Planet: Finding Superman's Krypton
NASA Astrophysics Data System (ADS)
Ricca, B.
2016-01-01
In 2012, Neil deGrasse Tyson made headlines when he appeared in a Superman comic book and pinpointed a real planet (located in Corvus) that matched the description of Superman's homeworld, the fictional planet of Krypton. This story tracked all over the world. Why? I will look at the figure of Superman, whose backstory—orphan from an exploding planet—is somehow known by everyone from the age of eight on. I will look at how specific astronomical phenomena (in the sky and in the news) may have inspired Superman's young teenaged creators in the 1930s to create this iconic modern myth—a myth, like many, grounded in astronomy. My goal is to show that comics—which we normally think of as juvenile, throwaway entertainment— actually tried to base themselves (and certainly were inspired by) actual astronomical events in the thirties and forties, made more accessible to the public by new scientific explanations, including a real supernova that may have inspired the destruction of Krypton.
Production and decay of K -shell hollow krypton in collisions with 52-197-MeV/u bare xenon ions
NASA Astrophysics Data System (ADS)
Shao, Caojie; Yu, Deyang; Cai, Xiaohong; Chen, Xi; Ma, Kun; Evslin, Jarah; Xue, Yingli; Wang, Wei; Kozhedub, Yury S.; Lu, Rongchun; Song, Zhangyong; Zhang, Mingwu; Liu, Junliang; Yang, Bian; Guo, Yipan; Zhang, Jianming; Ruan, Fangfang; Wu, Yehong; Zhang, Yuezhao; Dong, Chenzhong; Chen, Ximeng; Yang, Zhihu
2017-07-01
X-ray spectra of K -shell hollow krypton atoms produced in single collisions with 52-197-MeV/u X e54 + ions are measured in a heavy-ion storage ring equipped with an internal gas-jet target. Energy shifts of the K α1,2 s , K α1,2 h ,s , and K β1,3 s transitions are obtained. Thus the average number of the spectator L vacancies presented during the x-ray emission is deduced. From the relative intensities of the K α1,2 s and K α1,2 h ,s transitions, the ratio of K -shell hollow krypton to singly K -shell ionized atoms is determined to be 14 %-24 % . In the considered collisions, the K vacancies are mainly created by the direct ionization which cannot be calculated within the perturbation descriptions. The experimental results are compared with a relativistic coupled-channel calculation performed within the independent particle approximation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Colón, Yamil J.; Gómez-Gualdrón, Diego A.; Snurr, Randall Q.
Metal-organic frameworks (MOFs) are promising materials for a range of energy and environmental applications. Here we describe in detail a computational algorithm and code to generate MOFs based on edge-transitive topological nets for subsequent evaluation via molecular simulation. This algorithm has been previously used by us to construct and evaluate 13 512 MOFs of 41 different topologies for cryo-adsorbed hydrogen storage. Grand canonical Monte Carlo simulations are used here to evaluate the 13 512 structures for the storage of gaseous fuels such as hydrogen and methane and nondistillative separation of xenon/krypton mixtures at various operating conditions. MOF performance for bothmore » gaseous fuel storage and xenon/krypton separation is influenced by topology. Simulation data suggest that gaseous fuel storage performance is topology-dependent due to MOF properties such as void fraction and surface area combining differently in different topologies, whereas xenon/krypton separation performance is topology-dependent due to how topology constrains the pore size distribution.« less
L-shell spectroscopic diagnostics of radiation from krypton HED plasma sources.
Petkov, E E; Safronova, A S; Kantsyrev, V L; Shlyaptseva, V V; Rawat, R S; Tan, K S; Beiersdorfer, P; Hell, N; Brown, G V
2016-11-01
X-ray spectroscopy is a useful tool for diagnosing plasma sources due to its non-invasive nature. One such source is the dense plasma focus (DPF). Recent interest has developed to demonstrate its potential application as a soft x-ray source. We present the first spectroscopic studies of krypton high energy density plasmas produced on a 3 kJ DPF device in Singapore. In order to diagnose spectral features, and to obtain a more comprehensive understanding of plasma parameters, a new non-local thermodynamic equilibrium L-shell kinetic model for krypton was developed. It has the capability of incorporating hot electrons, with different electron distribution functions, in order to examine the effects that they have on emission spectra. To further substantiate the validity of this model, it is also benchmarked with data gathered from experiments on the electron beam ion trap (EBIT) at Lawrence Livermore National Laboratory, where data were collected using the high resolution EBIT calorimeter spectrometer.
L-shell spectroscopic diagnostics of radiation from krypton HED plasma sources
Petkov, E. E.; Safronova, A. S.; Kantsyrev, V. L.; ...
2016-08-09
We report that X-ray spectroscopy is a useful tool for diagnosing plasma sources due to its non-invasive nature. One such source is the dense plasma focus (DPF). Recent interest has developed to demonstrate its potential application as a soft x-ray source. We present the first spectroscopic studies of krypton high energy density plasmas produced on a 3 kJ DPF device in Singapore. In order to diagnose spectral features, and to obtain a more comprehensive understanding of plasma parameters, a new non-local thermodynamic equilibrium L-shell kinetic model for krypton was developed. It has the capability of incorporating hot electrons, with differentmore » electron distribution functions, in order to examine the effects that they have on emission spectra. Finally, to further substantiate the validity of this model, it is also benchmarked with data gathered from experiments on the electron beam ion trap (EBIT) at Lawrence Livermore National Laboratory, where data were collected using the high resolution EBIT calorimeter spectrometer.« less
L-shell spectroscopic diagnostics of radiation from krypton HED plasma sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petkov, E. E., E-mail: emilp@unr.edu; Safronova, A. S.; Kantsyrev, V. L.
2016-11-15
X-ray spectroscopy is a useful tool for diagnosing plasma sources due to its non-invasive nature. One such source is the dense plasma focus (DPF). Recent interest has developed to demonstrate its potential application as a soft x-ray source. We present the first spectroscopic studies of krypton high energy density plasmas produced on a 3 kJ DPF device in Singapore. In order to diagnose spectral features, and to obtain a more comprehensive understanding of plasma parameters, a new non-local thermodynamic equilibrium L-shell kinetic model for krypton was developed. It has the capability of incorporating hot electrons, with different electron distribution functions,more » in order to examine the effects that they have on emission spectra. To further substantiate the validity of this model, it is also benchmarked with data gathered from experiments on the electron beam ion trap (EBIT) at Lawrence Livermore National Laboratory, where data were collected using the high resolution EBIT calorimeter spectrometer.« less
Krypton gas cylinders as a source of radiation.
Fischer, Helmut W; Bielefeld, Tom; Hettwig, Bernd
2010-07-01
A standard 40 foot shipping container with a cargo of pressurized krypton gas in 159 steel cylinders, which had triggered a radiation alarm, was investigated to address radiation safety and illicit nuclear trafficking concerns. The investigation included contamination and dose rate measurements as well as in situ high resolution gamma spectroscopy. The dose rate measurements gave a maximum value of 0.07 microSv h(-1) above background (0.08 to 0.11 microSv h(-1)) on the cylinder surface and no detectable increase above background at distances of 1 m and higher. Contamination monitor readings showed a similar relative increase (plus 8 cpm) above background (about 12 cpm) to the dose rate readings. Quantitative gamma spectroscopy revealed a contamination of the gas with 85Kr at a level of 3.5 x 10(5) Bq kg(-1). This value was found to be consistent with analytical and numerical estimates based on current data for atmospheric 85Kr, which is captured from ambient air together with stable krypton during the production process. This incident demonstrates an apparent lack of radiation-related knowledge by those who handle krypton gas, as well as by border control personnel and emergency responders. We therefore propose to improve labeling and documentation standards for such shipments. This effort may be facilitated by introducing the new category of "technically enhanced artificial radioactive material," or "TEARM" (similar to the existing "naturally occurring radioactive material" or "NORM" and "technically enhanced naturally occurring radioactive material" or "TENORM" categories).
Multielectron transitions in x-ray absorption of krypton
NASA Astrophysics Data System (ADS)
Ito, Yoshiaki; Nakamatsu, Hirohide; Mukoyama, Takeshi; Omote, Kazuhiko; Yoshikado, Shinzo; Takahashi, Masao; Emura, Shuichi
1992-11-01
The photoabsorption cross section near the K edge in krypton gas has been measured using synchro- tron radiation. Several features for simultaneous multielectron excitations were detected and analyzed by the use of the shakeup and shakeoff probabilities and their dependence on the photon energy. Previous observations of the [1s3p], [1s3d], and [1s4p] transitions have been confirmed. A transition is found between [1s3p] and [1s3d] multiple excitations and identified as a three-electron excitation [1s3d4p].
Parkes, Marie V.; Demir, Hakan; Teich-McGoldrick, Stephanie L.; ...
2014-03-28
Molecular dynamics simulations were used to investigate trends in noble gas (Ar, Kr, Xe) diffusion in the metal-organic frameworks HKUST-1 and ZIF-8. Diffusion occurs primarily through inter-cage jump events, with much greater diffusion of guest atoms in HKUST-1 compared to ZIF-8 due to the larger cage and window sizes in the former. We compare diffusion coefficients calculated for both rigid and flexible frameworks. For rigid framework simulations, in which the framework atoms were held at their crystallographic or geometry optimized coordinates, sometimes dramatic differences in guest diffusion were seen depending on the initial framework structure or the choice of frameworkmore » force field parameters. When framework flexibility effects were included, argon and krypton diffusion increased significantly compared to rigid-framework simulations using general force field parameters. Additionally, for argon and krypton in ZIF-8, guest diffusion increased with loading, demonstrating that guest-guest interactions between cages enhance inter-cage diffusion. No inter-cage jump events were seen for xenon atoms in ZIF-8 regardless of force field or initial structure, and the loading dependence of xenon diffusion in HKUST-1 is different for rigid and flexible frameworks. Diffusion of krypton and xenon in HKUST-1 depends on two competing effects: the steric effect that decreases diffusion as loading increases, and the “small cage effect” that increases diffusion as loading increases. Finally, a detailed analysis of the window size in ZIF-8 reveals that the window increases beyond its normal size to permit passage of a (nominally) larger krypton atom.« less
Toward compact and ultra-intense laser driven soft x-ray lasers (Conference Presentation)
NASA Astrophysics Data System (ADS)
Sebban, Stéphane
2017-05-01
We report here recent work on an optical-field ionized (OFI), high-order harmonic-seeded EUV laser. The amplifying medium is a plasma of nickel-like krypton obtained by optical field ionization focusing a 1 J, 30 fs, circularly- polarized, infrared pulse into a krypton-filled gas cell or krypton gas jet. The lasing transition is the 3d94p (J=0) --> 3d94p (J=1) transition of Ni-like krypton ions at 32.8 nm and is pumped by collisions with hot electrons. The polarization of the HH-seeded EUV laser beam was studied using an analyzer composed of three grazing incidence EUV multilayer mirrors able to spin under vacuum. For linear polarization, the Malus law has been recovered while in the case of a circularly-polarized seed, the EUV signal is insensitive to the rotation of the analyzer, bearing testimony to circularly polarized. The gain dynamics was probed by seeding the amplifier with a high-order harmonic pulse at different delays. The gain duration monotonically decreased from 7 ps to an unprecedented shortness of 450 fs FWHM as the amplification peak rose from 150 to 1,200 with an increase of the plasma density from 3 × 1018 cm-3 up to 1.2 × 1020 cm-3. The integrated energy of the EUV laser pulse was also measured, and found to be around 2 μJ. It is to be noted that in the ASE mode, longer amplifiers were achieved (up to 3 cm), yielding EUV outputs up to 14 μJ.
Suzuki, Taku T; Sakaguchi, Isao
2016-01-01
Selective concentration of ultra-trace components in air-like gases has an important application in analyzing volatile organic compounds in the gas. In the present study, we examined quench-condensation of the sample gas on a ZnO substrate below 50 K followed by temperature programmed desorption (TPD) (low temperature TPD) as a selective gas concentration technique. We studied two specific gases in the normal air; krypton as an inert gas and acetone as a reactive gas. We evaluated the relationship between the operating condition of low temperature TPD and the lowest detection limit. In the case of krypton, we observed the selective concentration by exposing at 6 K followed by thermal desorption at about 60 K. On the other hand, no selectivity appeared for acetone although trace acetone was successfully concentrated. This is likely due to the solvent effect by a major component in the air, which is suggested to be water. We suggest that pre-condensation to remove the water component may improve the selectivity in the trace acetone analysis by low temperature TPD.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Troy G. Garn; Mitchell R. Greenhalgh; Jack D. Law
2013-10-01
The release of volatile radionuclides generated during Used Nuclear Fuel reprocessing in the US will most certainly need to be controlled to meet US regulatory emission limits. A US DOE sponsored Off-Gas Sigma Team has been tasked with a multi-lab collaborative research and development effort to investigate and evaluate emissions and immobilization control technologies for the volatile radioactive species generated from commercial Used Nuclear Fuel (UNF) Reprocessing. Physical Adsorption technology is a simpler and potential economical alternative to cryogenic distillation processes that can be used for the capture of krypton and xenon and has resulted in a novel composite sorbentmore » development procedure using synthesized mordenite as the active material. Utilizing the sorbent development procedure, INL sigma team members have developed two composite sorbents that have been evaluated for krypton and xenon capacities at ambient and 191 K temperature using numerous test gas compositions. Adsorption isotherms have been generated to predict equilibration and maximum capacities enabling modeling to support process equipment scale-up.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Troy G. Garn; Mitchell R. Greenhalgh; Jack D. Law
2013-09-01
The release of volatile radionuclides generated during Used Nuclear Fuel reprocessing in the US will most certainly need to be controlled to meet US regulatory emission limits. A US DOE sponsored Off-Gas Sigma Team has been tasked with a multi-lab collaborative research and development effort to investigate and evaluate emissions and immobilization control technologies for the volatile radioactive species generated from commercial Used Nuclear Fuel (UNF) Reprocessing. Physical Adsorption technology is a simpler and potential economical alternative to cryogenic distillation processes that can be used for the capture of krypton and xenon and has resulted in a novel composite sorbentmore » development procedure using synthesized mordenite as the active material. Utilizing the sorbent development procedure, INL sigma team members have developed two composite sorbents that have been evaluated for krypton and xenon capacities at ambient and 191 K temperature using numerous test gas compositions. Adsorption isotherms have been generated to predict equilibration and maximum capacities enabling modeling to support process equipment scale-up.« less
Removing krypton from xenon by cryogenic distillation to the ppq level
NASA Astrophysics Data System (ADS)
Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F. D.; Anthony, M.; Arneodo, F.; Barrow, P.; Baudis, L.; Bauermeister, B.; Benabderrahmane, M. L.; Berger, T.; Breur, P. A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Bütikofer, L.; Calvén, J.; Cardoso, J. M. R.; Cervantes, M.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Duchovni, E.; Eurin, G.; Fei, J.; Ferella, A. D.; Fieguth, A.; Franco, D.; Fulgione, W.; Gallo Rosso, A.; Galloway, M.; Gao, F.; Garbini, M.; Geis, C.; Goetzke, L. W.; Grandi, L.; Greene, Z.; Grignon, C.; Hasterok, C.; Hogenbirk, E.; Huhmann, C.; Itay, R.; Kaminsky, B.; Kessler, G.; Kish, A.; Landsman, H.; Lang, R. F.; Lellouch, D.; Levinson, L.; Calloch, M. Le; Lin, Q.; Lindemann, S.; Lindner, M.; Lopes, J. A. M.; Manfredini, A.; Maris, I.; Undagoitia, T. Marrodán; Masbou, J.; Massoli, F. V.; Masson, D.; Mayani, D.; Meng, Y.; Messina, M.; Micheneau, K.; Miguez, B.; Molinario, A.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Orrigo, S. E. A.; Pakarha, P.; Pelssers, B.; Persiani, R.; Piastra, F.; Pienaar, J.; Piro, M.-C.; Pizzella, V.; Plante, G.; Priel, N.; Rauch, L.; Reichard, S.; Reuter, C.; Rizzo, A.; Rosendahl, S.; Rupp, N.; Saldanha, R.; Santos, J. M. F. dos; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Shockley, E.; Silva, M.; Simgen, H.; Sivers, M. v.; Stein, A.; Thers, D.; Tiseni, A.; Trinchero, G.; Tunnell, C.; Upole, N.; Wang, H.; Wei, Y.; Weinheimer, C.; Wulf, J.; Ye, J.; Zhang, Y.; Cristescu, I.
2017-05-01
The XENON1T experiment aims for the direct detection of dark matter in a detector filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be sufficiently low. One major contributor is the β -emitter ^{85}Kr which is present in the xenon. For XENON1T a concentration of natural krypton in xenon ^{nat}Kr/Xe < 200 ppq (parts per quadrillion, 1 ppq =10^{-15} mol/mol) is required. In this work, the design, construction and test of a novel cryogenic distillation column using the common McCabe-Thiele approach is described. The system demonstrated a krypton reduction factor of 6.4\\cdot 10^5 with thermodynamic stability at process speeds above 3 kg/h. The resulting concentration of ^{nat}Kr/Xe<26 ppq is the lowest ever achieved, almost one order of magnitude below the requirements for XENON1T and even sufficient for future dark matter experiments using liquid xenon, such as XENONnT and DARWIN.
Four-body interaction energy for compressed solid krypton from quantum theory.
Tian, Chunling; Wu, Na; Liu, Fusheng; Saxena, Surendra K; Zheng, Xingrong
2012-07-28
The importance of the four-body contribution in compressed solid krypton was first evaluated using the many-body expansion method and the coupled cluster theory with full single and double excitations plus perturbative treatment of triples. All different four-atom clusters existing in the first- and second-nearest neighbor shells of face-centered cubic krypton were considered, and both self-consistent-field Hartree-Fock and correlation parts of the four-body interaction were accurately determined from the ambient conditions up to eightfold volume compression. We find that the four-body interaction energy is negative at compression ratio lower than 2, where the dispersive forces play a dominant role. With increasing the compression, the four-body contribution becomes repulsive and significantly cancels the over-softening effects of the three-body potential. The obtained equation of state (EOS) was compared with the experiments and the density-functional theory calculations. It shows that combination of the four-body effects with two- and three-body interactions leads to an excellent agreement with EOS measurements throughout the whole experimental range 0-130 GPa, and extends the prediction to 300 GPa.
Diagnosis of high-temperature implosions using low- and high-opacity Krypton lines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yaakobi, B.; Epstein, R.; Hooper, C.F. Jr.
1996-04-01
High-temperature laser target implosions can be achieved by using relatively thin-shell targets, and they can be. diagnosed by doping the fuel with krypton and measuring K-shell and L-shell lines. Electron temperatures of up to 5 keV at modest compressed densities ({approximately}1-5g/cm{sup 3}) are predicted for such experiments, with ion temperatures peaking above 10 keV at the center. It is found that the profiles of low-opacity (optically thin) lines in the expected density range are dominated by the Doppler broadening and can provide a measurement of the ion temperature if spectrometers of spectral resolution {Delta}{lambda}/{lambda} {ge} 1000 are used. For high-opacitymore » lines, obtained with a higher krypton fill pressure, the measurement of the escape factor can yield the {rho}R of the compressed fuel. At higher densities, Stark broadening of low-opacity lines becomes important and can provide a density measurement, whereas lines of higher opacity can be used to estimate the extent of mixing.« less
Radio-Krypton Dating with 20kg of Water or Ice
NASA Astrophysics Data System (ADS)
Hu, S. M.; Gu, J. Q.; Jiang, W.; Lu, Z. T.; Ritterbusch, F.; Yang, G. M.
2016-12-01
Long-lived noble-gas isotopes 85Kr (10.8 y), 39Ar (269 y) and 81Kr (229 ky) are ideal tracers for dating environmental samples such as groundwater and ice. Together with 14C, these nuclides can be used to cover the whole range of 100 - 106 y. To meet the increasing demands from the earth science community, a new, improved ATTA apparatus for radio-krypton analysis is being developed at the University of Science and Technology of China (USTC). From 2017, this instrument will be capable to analyze several hundred samples per year and also reduce the sample requirement to 1-2.5 μL STP of krypton gas, which can be extracted from 20-50 kg of water or 8-20 kg of ice. In parallel, a new sampling machine for use in the field is under test at USTC, which weighs less than 20kg and can be carried by one person. With this new dating tool sharpened, we believe that many more interesting applications can be carried out in collaboration with the earth science communities. (http://atta.ustc.edu.cn)
Effect of the fcc-hcp martensitic transition on the equation of state of solid krypton up to 140 GPa
NASA Astrophysics Data System (ADS)
Rosa, A. D.; Garbarino, G.; Briggs, R.; Svitlyk, V.; Morard, G.; Bouhifd, M. A.; Jacobs, J.; Irifune, T.; Mathon, O.; Pascarelli, S.
2018-03-01
Solid krypton (Kr) undergoes a pressure-induced martensitic phase transition from a face-centered cubic (fcc) to a hexagonal close-packed (hcp) structure. These two phases coexist in a very wide pressure domain inducing important modifications of the bulk properties of the resulting mixed phase system. Here, we report a detailed in situ x-ray diffraction and absorption study of the influence of the fcc-hcp phase transition on the compression behavior of solid krypton in an extended pressure domain up to 140 GPa. The onset of the hcp-fcc transformation was observed in this study at around 2.7 GPa and the coexistence of these two phases up to 140 GPa, the maximum investigated pressure. The appearance of the hcp phase is also evidenced by the pressure-induced broadening and splitting of the first peak in the XANES spectra. We demonstrate that the transition is driven by a continuous nucleation and intergrowth of nanometric hcp stacking faults that evolve in the fcc phase. These hcp stacking faults are unaffected by high-temperature annealing, suggesting that plastic deformation is not at their origin. The apparent small Gibbs free-energy differences between the two structures that decrease upon compression may explain the nucleation of hcp stacking faults and the large coexistence domain of fcc and hcp krypton. We observe a clear anomaly in the equation of state of the fcc solid at ˜20 GPa when the proportion of the hcp form reaches ˜20 % . We demonstrate that this anomaly is related to the difference in stiffness between the fcc and hcp phases and propose two distinct equation of states for the low and high-pressure regimes.
Anatomy of charge-exchange straggling
NASA Astrophysics Data System (ADS)
Sigmund, P.; Osmani, O.; Schinner, A.
2014-11-01
We have studied charge-exchange straggling theoretically for swift krypton and silicon ions and five target gases in the MeV/u energy regime. We find a pronounced two-peak structure for all ion-target combinations. The peak at the highest energy appears around the velocity where the bare ion and the one-electron ion are equally abundant in the equilibrium charge distribution. Correspondingly, the low-energy peak appears near the cross-over between the charge fractions of the two- and the three-electron ion. The possibility of further peaks at lower energies is discussed. Our findings are compared with recent experimental results on straggling of krypton beams.
Materials screening tests for the krypton-85 storage development program
NASA Astrophysics Data System (ADS)
Nagata, P. K.
1981-04-01
The results of a materials testing program for krypton-85 storage techniques are reported. Corrosion and stress corrosion tests were performed on a variety of materials including AISI 4130, Type 316 SS, Type 304 SS, Type 310 SS, Nitronic 50, and alloy A286. Test environments were high-purity liquid rubidium, liquid rubidium contaminated with oxygen, and rubidium hydroxide. Oxygen and water contaminations in liquid rubidium were found to greatly increase both general and localized corrosion of the materials tested. Alloy A286, Type 304 SS, and AISI 4130 were eliminated as candidate materials due to their susceptibility to general corrosion and stress corrosion cracking.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glass, R. W.; Gilliam, T. M.; Fowler, V. L.
An empirical model is presented for vapor-liquid equilibria and enthalpy for the CO$sub 2$-O$sub 2$ system. In the model, krypton and xenon in very low concentrations are combined with the CO$sub 2$-O$sub 2$ system, thereby representing the total system of primary interest in the High-Temperature Gas- Cooled Reactor program for removing krypton from off-gas generated during the reprocessing of spent fuel. Selected properties of the individual and combined components being considered are presented in the form of tables and empirical equations. (auth)
Krypton-81m ventilation scanning: acute respiratory disease
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lavender, J.P.; Irving, H.; Armstrong, J.D. II
1981-02-01
From experience with 700 patients undergoing ventilation and perfusion lung scanning with krypton-81m/technetium-99m technique, 34 patients suffering from nonembolic acute respiratory disease were selected for review. In 16 patients with pneumonia, all had defects of ventilation corresponding to, or larger than, the radiologic consolidation. In 13 patients there was some preservation of perfusion in the consolidated region. In two of the three patients with matched defects, the pneumonia was of long standing. In seven patients with collapse or atelectasis and in 11 patients with acute reversible bronchial obstruction and normal volume lungs, a similar pattern or ventillation and perfusion wasmore » observed.« less
Temperature Evolution of a 1 MA Triple-Nozzle Gas-Puff Z-Pinch
NASA Astrophysics Data System (ADS)
de Grouchy, Philip; Banasek, Jacob; Engelbrecht, Joey; Qi, Niansheng; Atoyan, Levon; Byvank, Tom; Cahill, Adam; Moore, Hannah; Potter, William; Ransohoff, Lauren; Hammer, David; Kusse, Bruce; Laboratory of Plasma Studies Team
2015-11-01
Mitigation of the Rayleigh-Taylor instability (RTI) plays a critical role in optimizing x-ray output at high-energy ~ 13 keV using the triple-nozzle Krypton gas-puff at Sandia National Laboratory. RTI mitigation by gas-puff density profiling using a triple-nozzle gas-puff valve has recently been recently demonstrated on the COBRA 1MA z-pinch at Cornell University. In support of this work we investigate the role of shell cooling in the growth of RTI during gas-puff implosions. Temperature measurements within the imploding plasma shell are recorded using a 527 nm, 10 GW Thomson scattering diagnostic for Neon, Argon and Krypton puffs. The mass-density profile is held constant at 22 microgram per centimeter for all three puffs and the temperature evolution of the imploding material is recorded. In the case of Argon puffs we find that the shell ion and electron effective temperatures remain in equilibrium at around 1keV for the majority of the implosion phase. In contrast scattered spectra from Krypton are dominated by of order 10 keV effective ion temperatures. Supported by the NNSA Stewardship Sciences Academic Programs.
The determination of accurate dipole polarizabilities alpha and gamma for the noble gases
NASA Technical Reports Server (NTRS)
Rice, Julia E.; Taylor, Peter R.; Lee, Timothy J.; Almloef, Jan
1989-01-01
The static dipole polarizabilities alpha and gamma for the noble gases helium through xenon were determined using large flexible one-particle basis sets in conjunction with high-level treatments of electron correlation. The electron correlation methods include single and double excitation coupled-cluster theory (CCSD), an extension of CCSD that includes a perturbational estimate of connected triple excitations, CCSD(T), and second order perturbation theory (MP2). The computed alpha and gamma values are estimated to be accurate to within a few percent. Agreement with experimental data for the static hyperpolarizability gamma is good for neon and xenon, but for argon and krypton the differences are larger than the combined theoretical and experimental uncertainties. Based on our calculations, we suggest that the experimental value of gamma for argon is too low; adjusting this value would bring the experimental value of gamma for krypton into better agreement with our computed result. The MP2 values for the polarizabilities of neon, argon, krypton and zenon are in reasonabe agreement with the CCSD and CCSD(T) values, suggesting that this less expensive method may be useful in studies of polarizabilities for larger systems.
Intrinsic backgrounds from Rn and Kr in the XENON100 experiment
NASA Astrophysics Data System (ADS)
Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F. D.; Anthony, M.; Arneodo, F.; Barrow, P.; Baudis, L.; Bauermeister, B.; Benabderrahmane, M. L.; Berger, T.; Breur, P. A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Bütikofer, L.; Calvén, J.; Cardoso, J. M. R.; Cervantes, M.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Eurin, G.; Fei, J.; Ferella, A. D.; Fieguth, A.; Fulgione, W.; Gallo Rosso, A.; Galloway, M.; Gao, F.; Garbini, M.; Geis, C.; Goetzke, L. W.; Greene, Z.; Grignon, C.; Hasterok, C.; Hogenbirk, E.; Itay, R.; Kaminsky, B.; Kazama, S.; Kessler, G.; Kish, A.; Landsman, H.; Lang, R. F.; Lellouch, D.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Manfredini, A.; Maris, I.; Marrodán Undagoitia, T.; Masbou, J.; Massoli, F. V.; Masson, D.; Mayani, D.; Messina, M.; Micheneau, K.; Molinario, A.; Morå, K.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Pakarha, P.; Pelssers, B.; Persiani, R.; Piastra, F.; Pienaar, J.; Piro, M.-C.; Pizzella, V.; Plante, G.; Priel, N.; Ramírez García, D.; Rauch, L.; Reichard, S.; Reuter, C.; Rizzo, A.; Rupp, N.; dos Santos, J. M. F.; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Silva, M.; Simgen, H.; Sivers, M. Von; Stein, A.; Thers, D.; Tiseni, A.; Trinchero, G.; Tunnell, C.; Vargas, M.; Wang, H.; Wang, Z.; Weber, M.; Wei, Y.; Weinheimer, C.; Wittweg, C.; Wulf, J.; Ye, J.; Zhang, Y.
2018-02-01
In this paper, we describe the XENON100 data analyses used to assess the target-intrinsic background sources radon (?), thoron (?) and krypton (?). We detail the event selections of high-energy alpha particles and decay-specific delayed coincidences. We derive distributions of the individual radionuclides inside the detector and quantify their abundances during the main three science runs of the experiment over a period of ˜ 4 years, from January 2010 to January 2014. We compare our results to external measurements of radon emanation and krypton concentrations where we find good agreement. We report an observed reduction in concentrations of radon daughters that we attribute to the plating-out of charged ions on the negatively biased cathode.
Cryogenic system with GM cryocooler for krypton, xenon separation from hydrogen-helium purge gas
NASA Astrophysics Data System (ADS)
Chu, X. X.; Zhang, M. M.; Zhang, D. X.; Xu, D.; Qian, Y.; Liu, W.
2014-01-01
In the thorium molten salt reactor (TMSR), fission products such as krypton, xenon and tritium will be produced continuously in the process of nuclear fission reaction. A cryogenic system with a two stage GM cryocooler was designed to separate Kr, Xe, and H2 from helium purge gas. The temperatures of two stage heat exchanger condensation tanks were maintained at about 38 K and 4.5 K, respectively. The main fluid parameters of heat transfer were confirmed, and the structural heat exchanger equipment and cold box were designed. Designed concentrations after cryogenic separation of Kr, Xe and H2 in helium recycle gas are less than 1 ppb.
Excitation of vacuum ultraviolet spectra of krypton in a cooled gas discharge
NASA Astrophysics Data System (ADS)
Gerasimov, Gennadii N.; Krylov, Boris E.; Hallin, Reinhold
1995-08-01
Results are presented on the experimental study of VUV spectra of krypton excited by a dc discharge in a capillary tube with the wall cooled to the temperature of liquid nitrogen. We studied the 120-200 nm spectral region corresponding to the transitions between the dimer lowest excited states and the weakly bound ground state, 1u, 0u+ yields 0g+. Electron impact, transferring dimers from the ground state into the excited state, is shown to be an efficient excitation mechanism in the 50-650 Torr and the 10-50 mA pressure and current ranges. The spectra obtained and the calculations made corroborate the high rate of this process.
Photolytic separation of isotopes in cryogenic solution
Freund, S.M.; Maier, W.B. II; Holland, R.F.; Battie, W.H.
Separation of carbon isotopes by photolysis of CS/sub 2/ in cryogenic solutions of nitrogen, krypton and argon with 206 nm light from an iodine resonance lamp is reported. The spectral distributionn of the ultraviolet absorption depends on solvent. Thus, in liquid nitrogen the photolytic decomposition rate of /sup 13/CS/sub 2/ is greater than that of /sup 12/CS/sub 2/ (because the absorption of 206 nm radiation is greater for /sup 13/CS/sub 2/), whereas in liquid krypton and liquid argon the reverse is true. The shift in ultraviolet spectrum is a general phenomenon readily characterized as a function of solvent polarizability, and exhibits behavior similar to that for vibrational transitions occurring in the infrared.
Photolytic separation of isotopes in cryogenic solution
Freund, Samuel M.; Maier, II, William B.; Holland, Redus F.; Beattie, Willard H.
1985-01-01
Separation of carbon isotopes by photolysis of CS.sub.2 in cryogenic solutions of nitrogen, krypton and argon with 206 nm light from an iodine resonance lamp is reported. The spectral distribution of the ultraviolet absorption depends on solvent. Thus, in liquid nitrogen the photolytic decomposition rate of .sup.13 CS.sub.2 is greater than that of .sup.12 CS.sub.2 (because the absorption of 206 nm radiation is greater for .sup.13 CS.sub.2), whereas in liquid krypton and liquid argon the reverse is true. The shift in ultraviolet spectrum is a general phenomenon readily characterized as a function of solvent polarizability, and exhibits behavior similar to that for vibrational transitions occurring in the infrared.
NASA Astrophysics Data System (ADS)
Qiu, Jie; Cheng, Zhi-Wen; Zhu, Xi-Ming; Pu, Yi-Kang
2018-04-01
The rate coefficients for the electron-impact transfer from Kr(1s5) to Kr(1s4) and from Kr(1s3) to Kr(1s2) are measured in the electron temperature (T e) range between 0.07 eV and 1 eV. In the afterglow of a capacitive krypton discharge at a fixed pressure of 20 mTorr and a peak rf power ranging from 4 to 128 W, the densities of four krypton 1s states, the electron temperature and the electron density are measured by diode laser absorption, a Langmuir probe and a microwave interferometer, respectively. With these measured quantities, the rate coefficients are obtained from a population model for krypton metastable states. The measured rate coefficients are compared with those derived from the excitation cross sections of Kr metastable states calculated by different R-matrix models. It is found that our results agree best with that from Allan et al [1]. Moreover, we analyze the assumptions made in the population model and discuss their possible impact on the accuracy of the measured rate coefficients, especially for the low T e (0.1-0.2 eV) range and a higher T e (0.4-1 eV) range.
NASA Astrophysics Data System (ADS)
Goodrich, Michael E.; Moore, David T.
2016-06-01
The separated CO2 dimer anion, (CO2)(CO2-), is observed by FTIR spectroscopy in matrix isolation experiments at 1652 cm-1 upon deposition of high energy argon ions into an argon matrix doped with 0.5% CO2. It has previously been reported by Andrews that upon annealing the matrix to 25K, the separated species converts to an oxalate-like C2O4- species which appears at 1856 cm-1.a We have observed that subsequently holding the matrix at 10K caused the C2O4- species to fully convert back to (CO2)(CO2-). Upon further investigation, we determined that the two species reversibly interconvert between 19K and 23K, suggesting the species are in thermodynamic equilibrium. The associated van't Hoff plot has a linear trend and indicates an endothermic reaction driven by a large increase in entropy. An analogous experiment in a krypton matrix was performed, and the equilibrium was found to occur between 26K and 31K. Interestingly, analysis revealed the reaction in krypton is more endothermic, but has nearly the same entropy value as was observed in the argon experiment. aZhou, M.; Andrews, L.; J. Chem. Phys. 110, 2414 (1999).
Shock Compression of Liquid Noble Gases to Multi-Mbar Pressures
NASA Astrophysics Data System (ADS)
Root, Seth
2011-10-01
The high pressure - high temperature behavior of noble gases is of considerable interest because of their use in z-pinch liners for fusion studies and for understanding astrophysical and planetary evolution. However, our understanding of the equation of state (EOS) of the noble gases at extreme conditions is limited. A prime example of this is the liquid xenon Hugoniot. Previous EOS models rapidly diverged on the Hugoniot above 1 Mbar because of differences in the treatment of the electronic contribution to the free energy. Similar divergences are observed for krypton EOS. Combining shock compression experiments and density functional theory (DFT) simulations, we can determine the thermo-physical behavior of matter under extreme conditions. The experimental and DFT results have been instrumental to recent developments in planetary astrophysics and inertial confinement fusion. Shock compression experiments are performed using Sandia's Z-Accelerator to determine the Hugoniot of liquid xenon and krypton in the Mbar regime. Under strong pressure, krypton and xenon undergo an insulator to metal transition. In the metallic state, the shock front becomes reflective allowing for a direct measurement of the sample's shock velocity using laser interferometry. The Hugoniot state is determined using a Monte Carlo analysis method that accounts for systematic error in the standards and for correlations. DFT simulations at these extreme conditions show good agreement with the experimental data - demonstrating the attention to detail required for dealing with elements with relativistic core states and d-state electrons. The results from shock compression experiments and DFT simulations are presented for liquid xenon to 840 GPa and for liquid krypton to 800 GPa, decidedly increasing the range of known behavior of both gases. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Company, for the U. S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.
Hypersonic Wake Diagnostics Using Laser Induced Fluorescence Techniques
NASA Technical Reports Server (NTRS)
Mills, Jack L.; Sukenik, Charles I.; Balla, Robert J.
2011-01-01
A review of recent research performed in iodine that involves a two photon absorption of light at 193 nm will be discussed, and it's potential application to velocimetry measurements in a hypersonic flow field will be described. An alternative seed atom, Krypton, will be presented as a good candidate for performing nonintrusive hypersonic flow diagnostics. Krypton has a metastable state with a lifetime of approximately 43 s which would prove useful for time of flight measurement (TOF) and a sensitivity to collisions that can be utilized for density measurements. Calculations using modest laser energies and experimental values show an efficiency of excited state production to be on the order of 10(exp -6) for a two photon absorption at 193 nm.
Cryogenic system with GM cryocooler for krypton, xenon separation from hydrogen-helium purge gas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chu, X. X.; Zhang, D. X.; Qian, Y.
2014-01-29
In the thorium molten salt reactor (TMSR), fission products such as krypton, xenon and tritium will be produced continuously in the process of nuclear fission reaction. A cryogenic system with a two stage GM cryocooler was designed to separate Kr, Xe, and H{sub 2} from helium purge gas. The temperatures of two stage heat exchanger condensation tanks were maintained at about 38 K and 4.5 K, respectively. The main fluid parameters of heat transfer were confirmed, and the structural heat exchanger equipment and cold box were designed. Designed concentrations after cryogenic separation of Kr, Xe and H{sub 2} in heliummore » recycle gas are less than 1 ppb.« less
Monolayer adsorption of noble gases on graphene
NASA Astrophysics Data System (ADS)
Maiga, Sidi M.; Gatica, Silvina M.
2018-02-01
We report our results of simulations of the adsorption of noble gases (Kr, Ar, Xe) on graphene. For Kr, we consider two configurations: supported and free-standing graphene, where atoms are adsorbed only on one or two sides of the graphene. For Ar and Xe, we studied only the case of supported graphene. For the single-side adsorption, we calculated the two-dimensional gas-liquid critical temperature for each adsorbate. We determined the different phases of the monolayers and constructed the phase diagrams. We found two-dimensional incommensurate solid phases for krypton, argon and xenon, and a two-dimensional commensurate solid phase for krypton. For double side adsorption of Kr, we do not see evidence of an ordering transition driven by the interlayer forces.
Ellipsometry with polarisation analysis at cryogenic temperatures inside a vacuum chamber
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bauer, S.; Grees, B.; Spitzer, D.
2013-12-15
In this paper we describe a new variant of null ellipsometry to determine thicknesses and optical properties of thin films on a substrate at cryogenic temperatures. In the PCSA arrangement of ellipsometry the polarizer and the compensator are placed before the substrate and the analyzer after it. Usually, in the null ellipsometry the polarizer and the analyzer are rotated to find the searched minimum in intensity. In our variant we rotate the polarizer and the compensator instead, both being placed in the incoming beam before the substrate. Therefore the polarisation analysis of the reflected beam can be realized by anmore » analyzer at fixed orientation. We developed this method for investigations of thin cryogenic films inside a vacuum chamber where the analyzer and detector had to be placed inside the cold shield at a temperature of T≈ 90 K close to the substrate. All other optical components were installed at the incoming beam line outside the vacuum chamber, including all components which need to be rotated during the measurements. Our null ellipsometry variant has been tested with condensed krypton films on a highly oriented pyrolytic graphite substrate (HOPG) at a temperature of T≈ 25 K. We show that it is possible to determine the indices of refraction of condensed krypton and of the HOPG substrate as well as thickness of krypton films with reasonable accuracy.« less
Supershort avalanche electron beam in SF6 and krypton
NASA Astrophysics Data System (ADS)
Zhang, Cheng; Tarasenko, Victor F.; Gu, Jianwei; Baksht, Evgeni Kh.; Beloplotov, Dmitry V.; Burachenko, Alexander G.; Yan, Ping; Lomaev, Mikhail I.; Shao, Tao
2016-03-01
Runaway electrons play an important role in the avalanche formation in nanosecond- and subnanosecond- pulse discharges. In this paper, characteristics of a supershort avalanche electron beam (SAEB) generated at the subnanosecond and nanosecond breakdown in sulfur hexafluoride (SF6 ) in an inhomogeneous electric field were studied. One pulser operated at negative polarity with voltage pulse amplitude of ˜130 kV and rise time of 0.3 ns. The other pulser operated at negative polarity with voltage pulse amplitude of 70 kV and rise time of ˜1.6 ns . SAEB parameters in SF6 are compared with those obtained in krypton (Kr), nitrogen (N2 ), air, and mixtures of SF6 with krypton or nitrogen. Experimental results showed that SAEB currents appeared during the rise-time of the voltage pulse for both pulsers. Moreover, amplitudes of the SAEB current in SF6 and Kr approximately ranged from several to tens of milliamps at atmospheric pressure, which were smaller than those in N2 and air (ranging from hundreds of milliamps to several amperes). Furthermore, the concentration of SF6 additive could significantly reduce the SAEB current in N2-SF6 mixture, but it slightly affected the SAEB current in Kr -SF6 mixture because of the atomic/molecular ionization cross section of the gas had a much greater impact on the SAEB current rather than the electronegativity.
NASA Astrophysics Data System (ADS)
Bulanin, Kirill M.; Bulanin, Michael O.; Rudakova, Aida V.; Kolomijtsova, Tatiana D.; Shchepkin, Dmitrij N.
2018-03-01
We have measured and interpreted the IR spectra of ozone dissolved in liquid nitrogen, oxygen, argon, and krypton in the 650-4700 cm-1 spectral region at 79-117 K. Frequency shifts, band intensities and bandshapes of 22 spectral features of soluted ozone were analyzed. The bands of the A1 symmetry have a complex contour and possess an excess intensity with respect to the value of the purely vibrational transition moment. It was found that this effect is related to the manifestation of the Coriolis interaction. The bandshape distortion manifests itself as an additional intensity from the side of the B1 symmetry band being an intensity source in the case of the Coriolis interaction.
NASA Technical Reports Server (NTRS)
Palma, R. L.; Heymann, D.
1988-01-01
Inert gases released by stepwise heating of unaltered, strongly magnetic, and weakly magnetic samples from the 0-64 micron and the 105-250 micron fractions of a disaggregated and sieved sample of the Allende meteorite reveal the occurrence of both solar and planetary neon. The origin of the solar neon is thought to be implantation of solar wind ions. The origin of the planetary neon remains unresolved. Heavy isotope enriched components of krypton and xenon have been detected and there are some indications that a light krypton component may also be present. Other than a larger concentration of Xe-129 in the weakly magnetic samples, the signatures of the magnetic separates are isotopically very similar.
A new site for 85Kr measurements on groundwater samples
NASA Astrophysics Data System (ADS)
Lange, T.; Hebert, D.
2001-06-01
As a part of a new 85Kr laboratory, which is currently being established at the Institute of Applied Physics in Freiberg, Germany, a modified CO 2 extractor for krypton sampling is used. The operation principle is simple and contamination-safe with a reasonable effort. Continuously pumped under pressure, the water passes a Venturi-type nozzle and degasses due to relaxing. The extracted gas mixture then enters a recirculation system flowing through a CO 2 trap (NaOH), molecular sieves and a cooled charcoal trap, where krypton and other components are adsorbed. Remaining gases reenter the system at the Venturi-type nozzle. To keep the circulation alive an additional helium support is needed. In a simple field experiment, extraction efficiencies up to 0.8 for 222Rn have been measured.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, I.; Quevedo, H. J.; Feldman, S.
2013-12-15
Radiative blast waves were created by irradiating a krypton cluster source from a supersonic jet with a high intensity femtosecond laser pulse. It was found that the radiation from the shock surface is absorbed in the optically thick upstream medium creating a radiative heat wave that travels supersonically ahead of the main shock. As the blast wave propagates into the heated medium, it slows and loses energy, and the radiative heat wave also slows down. When the radiative heat wave slows down to the transonic regime, a secondary shock in the ionization precursor is produced. This paper presents experimental datamore » characterizing both the initial and secondary shocks and numerical simulations to analyze the double-shock dynamics.« less
On krypton-doped capsule implosion experiments at the National Ignition Facility
NASA Astrophysics Data System (ADS)
Chen, Hui; Ma, T.; Nora, R.; Barrios, M. A.; Scott, H. A.; Schneider, M. B.; Berzak Hopkins, L.; Casey, D. T.; Hammel, B. A.; Jarrott, L. C.; Landen, O. L.; Patel, P. K.; Rosenberg, M. J.; Spears, B. K.
2017-07-01
This paper presents the spectroscopic aspects of using Krypton as a dopant in NIF capsule implosions through simulation studies and the first set of NIF experiments. Using a combination of 2D hohlraum and 1D capsule simulations with comprehensive spectroscopic modeling, the calculations focused on the effect of dopant concentration on the implosion, and the impact of gradients in the electron density and temperature to the Kr line features and plasma opacity. Experimental data were obtained from three NIF Kr-dopant experiments, performed with varying Kr dopant concentrations between 0.01% and 0.03%. The implosion performance, hotspot images, and detailed Kr spectral analysis are summarized relative to the predictions. Data show that fuel-dopant spectroscopy can serve as a powerful and viable diagnostic for inertial confinement fusion implosions.
NASA Technical Reports Server (NTRS)
Niemann, H. B.; Atreya, S. K.; Carignan, G. R.; Donahue, T. M.; Haberman, J. A.; Harpold, D. N.; Hartle, R. E.; Hunten, D. M.; Kasprzak, W. T.; Mahaffy, P. R.;
1998-01-01
The Galileo Probe entered the atmosphere of Jupiter on December 7, 1995. Measurements of the chemical and isotopic composition of the Jovian atmosphere were obtained by the mass spectrometer during the descent over the 0.5 to 21 bar pressure region over a time period of approximately 1 hour. The sampling was either of atmospheric gases directly introduced into the ion source of the mass spectrometer through capillary leaks or of gas, which had been chemically processed to enhance the sensitivity of the measurement to trace species or noble gases. The analysis of this data set continues to be refined based on supporting laboratory studies on an engineering unit. The mixing ratios of the major constituents of the atmosphere hydrogen and helium have been determined as well as mixing ratios or upper limits for several less abundant species including: methane, water, ammonia, ethane, ethylene, propane, hydrogen sulfide, neon, argon, krypton, and xenon. Analysis also suggests the presence of trace levels of other 3 and 4 carbon hydrocarbons, or carbon and nitrogen containing species, phosphine, hydrogen chloride, and of benzene. The data set also allows upper limits to be set for many species of interest which were not detected. Isotope ratios were measured for 3He/4He, D/H, 13C/12C, 20Ne/22Ne, 38Ar/36Ar and for isotopes of both Kr and Xe.
Niemann, H B; Atreya, S K; Carignan, G R; Donahue, T M; Haberman, J A; Harpold, D N; Hartle, R E; Hunten, D M; Kasprzak, W T; Mahaffy, P R; Owen, T C; Spencer, N W
1998-01-01
The Galileo Probe entered the atmosphere of Jupiter on December 7, 1995. Measurements of the chemical and isotopic composition of the Jovian atmosphere were obtained by the mass spectrometer during the descent over the 0.5 to 21 bar pressure region over a time period of approximately 1 hour. The sampling was either of atmospheric gases directly introduced into the ion source of the mass spectrometer through capillary leaks or of gas, which had been chemically processed to enhance the sensitivity of the measurement to trace species or noble gases. The analysis of this data set continues to be refined based on supporting laboratory studies on an engineering unit. The mixing ratios of the major constituents of the atmosphere hydrogen and helium have been determined as well as mixing ratios or upper limits for several less abundant species including: methane, water, ammonia, ethane, ethylene, propane, hydrogen sulfide, neon, argon, krypton, and xenon. Analysis also suggests the presence of trace levels of other 3 and 4 carbon hydrocarbons, or carbon and nitrogen containing species, phosphine, hydrogen chloride, and of benzene. The data set also allows upper limits to be set for many species of interest which were not detected. Isotope ratios were measured for 3He/4He, D/H, 13C/12C, 20Ne/22Ne, 38Ar/36Ar and for isotopes of both Kr and Xe.
NASA Astrophysics Data System (ADS)
Niemann, H. B.; Atreya, S. K.; Carignan, G. R.; Donahue, T. M.; Haberman, J. A.; Harpold, D. N.; Hartle, R. E.; Hunten, D. M.; Kasprzak, W. T.; Mahaffy, P. R.; Owen, T. C.; Spencer, N. W.
The Galileo Probe entered the atmosphere of Jupiter on December 7, 1995. Measurements of the chemical and isotopic composition of the Jovian atmosphere were obtained by the mass spectrometer during the descent over the 0.5 to 21 bar pressure region over a time period of approximately 1 hour. The sampling was either of atmospheric gases directly introduced into the ion source of the mass spectrometer through capillary leaks or of gas, which had been chemically processed to enhance the sensitivity of the measurement to trace species or noble gases. The analysis of this data set continues to be refined based on supporting laboratory studies on an engineering unit. The mixing ratios of the major constituents of the atmosphere hydrogen and helium have been determined as well as mixing ratios or upper limits for several less abundant species including: methane, water, ammonia, ethane, ethylene, propane, hydrogen sulfide, neon, argon, krypton, and xenon. Analysis also suggests the presence of trace levels of other 3 and 4 carbon hydrocarbons, or carbon and nitrogen containing species, phosphine, hydrogen chloride, and of benzene. The data set also allows upper limits to be set for many species of interest which were not detected. Isotope ratios were measured for ^3He/^4He, D/H, ^13C/^12C, ^20Ne/^22Ne, ^38Ar/^36Ar and for isotopes of both Kr and Xe.
High-accuracy deep-UV Ramsey-comb spectroscopy in krypton
NASA Astrophysics Data System (ADS)
Galtier, Sandrine; Altmann, Robert K.; Dreissen, Laura S.; Eikema, Kjeld S. E.
2017-01-01
In this paper, we present a detailed account of the first precision Ramsey-comb spectroscopy in the deep UV. We excite krypton in an atomic beam using pairs of frequency-comb laser pulses that have been amplified to the millijoule level and upconverted through frequency doubling in BBO crystals. The resulting phase-coherent deep-UV pulses at 212.55 nm are used in the Ramsey-comb method to excite the two-photon 4p^6 → 4p^5 5p [1/2 ]_0 transition. For the {}^{84}Kr isotope, we find a transition frequency of 2829833101679(103) kHz. The fractional accuracy of 3.7 × 10^{-11} is 34 times better than previous measurements, and also the isotope shifts are measured with improved accuracy. This demonstration shows the potential of Ramsey-comb excitation for precision spectroscopy at short wavelengths.
Bulanin, Kirill M; Bulanin, Michael O; Rudakova, Aida V; Kolomijtsova, Tatiana D; Shchepkin, Dmitrij N
2018-03-15
We have measured and interpreted the IR spectra of ozone dissolved in liquid nitrogen, oxygen, argon, and krypton in the 650-4700cm -1 spectral region at 79-117K. Frequency shifts, band intensities and bandshapes of 22 spectral features of soluted ozone were analyzed. The bands of the А 1 symmetry have a complex contour and possess an excess intensity with respect to the value of the purely vibrational transition moment. It was found that this effect is related to the manifestation of the Coriolis interaction. The bandshape distortion manifests itself as an additional intensity from the side of the В 1 symmetry band being an intensity source in the case of the Coriolis interaction. Copyright © 2017. Published by Elsevier B.V.
Kr-PLIF for scalar imaging in supersonic flows.
Narayanaswamy, V; Burns, R; Clemens, N T
2011-11-01
Experiments were performed to explore the use of two-photon planar laser-induced fluorescence (PLIF) of krypton gas for applications of scalar imaging in supersonic flows. Experiments were performed in an underexpanded jet of krypton, which exhibited a wide range of conditions, from subsonic to hypersonic. Excellent signal-to-noise ratios were obtained, showing the technique is suitable for single-shot imaging. The data were used to infer the distribution of gas density and temperature by correcting the fluorescence signal for quenching effects and using isentropic relations. The centerline variation of the density and temperature from the experiments agree very well with those predicted with an empirical correlation and a CFD simulation (FLUENT). Overall, the high signal levels and quantifiable measurements indicate that Kr-PLIF could be an effective scalar marker for use in supersonic and hypersonic flow applications.
Shape Evolution in Neutron-Rich Krypton Isotopes Beyond N =60 : First Spectroscopy of Kr,10098
NASA Astrophysics Data System (ADS)
Flavigny, F.; Doornenbal, P.; Obertelli, A.; Delaroche, J.-P.; Girod, M.; Libert, J.; Rodriguez, T. R.; Authelet, G.; Baba, H.; Calvet, D.; Château, F.; Chen, S.; Corsi, A.; Delbart, A.; Gheller, J.-M.; Giganon, A.; Gillibert, A.; Lapoux, V.; Motobayashi, T.; Niikura, M.; Paul, N.; Roussé, J.-Y.; Sakurai, H.; Santamaria, C.; Steppenbeck, D.; Taniuchi, R.; Uesaka, T.; Ando, T.; Arici, T.; Blazhev, A.; Browne, F.; Bruce, A.; Carroll, R.; Chung, L. X.; Cortés, M. L.; Dewald, M.; Ding, B.; Franchoo, S.; Górska, M.; Gottardo, A.; Jungclaus, A.; Lee, J.; Lettmann, M.; Linh, B. D.; Liu, J.; Liu, Z.; Lizarazo, C.; Momiyama, S.; Moschner, K.; Nagamine, S.; Nakatsuka, N.; Nita, C.; Nobs, C. R.; Olivier, L.; Orlandi, R.; Patel, Z.; Podolyák, Zs.; Rudigier, M.; Saito, T.; Shand, C.; Söderström, P. A.; Stefan, I.; Vaquero, V.; Werner, V.; Wimmer, K.; Xu, Z.
2017-06-01
We report on the first γ -ray spectroscopy of low-lying states in neutron-rich Kr,10098 isotopes obtained from Rb,10199(p ,2 p ) reactions at ˜220 MeV /nucleon . A reduction of the 21+ state energies beyond N =60 demonstrates a significant increase of deformation, shifted in neutron number compared to the sharper transition observed in strontium and zirconium isotopes. State-of-the-art beyond-mean-field calculations using the Gogny D1S interaction predict level energies in good agreement with experimental results. The identification of a low-lying (02+, 22+) state in
Pressure broadening and frequency shift of the D 1 and D 2 lines of K in the presence of Ne and Kr
NASA Astrophysics Data System (ADS)
Wang, Xulin; Chen, Yao; Quan, Wei; Chi, Haotian; Fang, Jiancheng
2018-02-01
We present the results of pressure broadening and frequency shift of K D 1 and D 2 lines in presence of 1-4 amg of Neon gas and 1-5 amg of Krypton gas by laser absorption spectroscopy. Both pressure broadening and frequency shift are linearly related to gas density with high accuracy. The asymmetry of the absorption line shape caused by van der Waals potential was first found in the near-line wings of large density Kr in the experiment. We have also investigated the temperature dependence of the pressure broadening and frequency shift in a range of 353-403 K in Neon and 373-417 K in Krypton and compared the results of the pressure broadening and frequency shift with previous values.
10 CFR 30.15 - Certain items containing byproduct material.
Code of Federal Regulations, 2014 CFR
2014-01-01
... of tritium per any other electron tube; (ii) 1 microcurie of cobalt-60; (iii) 5 microcuries of nickel-63; (iv) 30 microcuries of krypton-85; (v) 5 microcuries of cesium-137; (vi) 30 microcuries of...
10 CFR 30.15 - Certain items containing byproduct material.
Code of Federal Regulations, 2013 CFR
2013-01-01
... of tritium per any other electron tube; (ii) 1 microcurie of cobalt-60; (iii) 5 microcuries of nickel-63; (iv) 30 microcuries of krypton-85; (v) 5 microcuries of cesium-137; (vi) 30 microcuries of...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yates, Brent R.; Khakoo, Murtadha A.
2011-04-15
We present normalized doubly differential cross sections (DDCS's) for the near-threshold, electron-impact single ionization of argon and krypton, similar to those taken earlier for Ne and Xe [Yates et al., J. Phys. B 42, 095206 (2009)]. The Ar measurements were taken at incident energies of 17, 18, 20, and 30 eV while the Kr measurements were taken at 15, 16, 17.5, and 20 eV. The DDCS scattering angles range from 15 deg. to 120 deg. The differential data are initially normalized to available experimental cross sections for excitation of the ground np{sup 6} to the np{sup 5}(n+1)s excited states ofmore » the noble gas and, after integration, to well-established experimental total ionization cross sections of Rapp and Englander-Golden [J. Chem. Phys. 43, 1464 (1965)].« less
Computational modeling of Krypton gas puffs with tailored mass density profiles on Z
Jennings, Christopher A.; Ampleford, David J.; Lamppa, Derek C.; ...
2015-05-18
Large diameter multi-shell gas puffs rapidly imploded by high current (~20 MA, ~100 ns) on the Z generator of Sandia National Laboratories are able to produce high-intensity Krypton K-shell emission at ~13 keV. Efficiently radiating at these high photon energies is a significant challenge which requires the careful design and optimization of the gas distribution. To facilitate this, we hydrodynamically model the gas flow out of the nozzle and then model its implosion using a 3-dimensional resistive, radiative MHD code (GORGON). This approach enables us to iterate between modeling the implosion and gas flow from the nozzle to optimize radiativemore » output from this combined system. Furthermore, guided by our implosion calculations, we have designed gas profiles that help mitigate disruption from Magneto-Rayleigh–Taylor implosion instabilities, while preserving sufficient kinetic energy to thermalize to the high temperatures required for K-shell emission.« less
Ultrafast quantum control of ionization dynamics in krypton.
Hütten, Konrad; Mittermair, Michael; Stock, Sebastian O; Beerwerth, Randolf; Shirvanyan, Vahe; Riemensberger, Johann; Duensing, Andreas; Heider, Rupert; Wagner, Martin S; Guggenmos, Alexander; Fritzsche, Stephan; Kabachnik, Nikolay M; Kienberger, Reinhard; Bernhardt, Birgitta
2018-02-19
Ultrafast spectroscopy with attosecond resolution has enabled the real time observation of ultrafast electron dynamics in atoms, molecules and solids. These experiments employ attosecond pulses or pulse trains and explore dynamical processes in a pump-probe scheme that is selectively sensitive to electronic state of matter via photoelectron or XUV absorption spectroscopy or that includes changes of the ionic state detected via photo-ion mass spectrometry. Here, we demonstrate how the implementation of combined photo-ion and absorption spectroscopy with attosecond resolution enables tracking the complex multidimensional excitation and decay cascade of an Auger auto-ionization process of a few femtoseconds in highly excited krypton. In tandem with theory, our study reveals the role of intermediate electronic states in the formation of multiply charged ions. Amplitude tuning of a dressing laser field addresses different groups of decay channels and allows exerting temporal and quantitative control over the ionization dynamics in rare gas atoms.
NASA Astrophysics Data System (ADS)
Miller, Nicholas A. T.; Daivis, Peter J.; Snook, Ian K.; Todd, B. D.
2013-10-01
Thermophoresis is the movement of molecules caused by a temperature gradient. Here we report the results of a study of thermophoresis using non-equilibrium molecular dynamics simulations of a confined argon-krypton fluid subject to two different temperatures at thermostated walls. The resulting temperature profile between the walls is used along with the Soret coefficient to predict the concentration profile that develops across the channel. We obtain the Soret coefficient by calculating the mutual diffusion and thermal diffusion coefficients. We report an appropriate method for calculating the transport coefficients for binary systems, using the Green-Kubo integrals and radial distribution functions obtained from equilibrium molecular dynamics simulations of the bulk fluid. Our method has the unique advantage of separating the mutual diffusion and thermal diffusion coefficients, and calculating the sign and magnitude of their individual contributions to thermophoresis in binary mixtures.
Chromatographic separation of radioactive noble gases from xenon
NASA Astrophysics Data System (ADS)
Akerib, D. S.; Araújo, H. M.; Bai, X.; Bailey, A. J.; Balajthy, J.; Beltrame, P.; Bernard, E. P.; Bernstein, A.; Biesiadzinski, T. P.; Boulton, E. M.; Bramante, R.; Cahn, S. B.; Carmona-Benitez, M. C.; Chan, C.; Chiller, A. A.; Chiller, C.; Coffey, T.; Currie, A.; Cutter, J. E.; Davison, T. J. R.; Dobi, A.; Dobson, J. E. Y.; Druszkiewicz, E.; Edwards, B. N.; Faham, C. H.; Fiorucci, S.; Gaitskell, R. J.; Gehman, V. M.; Ghag, C.; Gibson, K. R.; Gilchriese, M. G. D.; Hall, C. R.; Hanhardt, M.; Haselschwardt, S. J.; Hertel, S. A.; Hogan, D. P.; Horn, M.; Huang, D. Q.; Ignarra, C. M.; Ihm, M.; Jacobsen, R. G.; Ji, W.; Kamdin, K.; Kazkaz, K.; Khaitan, D.; Knoche, R.; Larsen, N. A.; Lee, C.; Lenardo, B. G.; Lesko, K. T.; Lindote, A.; Lopes, M. I.; Manalaysay, A.; Mannino, R. L.; Marzioni, M. F.; McKinsey, D. N.; Mei, D.-M.; Mock, J.; Moongweluwan, M.; Morad, J. A.; Murphy, A. St. J.; Nehrkorn, C.; Nelson, H. N.; Neves, F.; O'Sullivan, K.; Oliver-Mallory, K. C.; Palladino, K. J.; Pease, E. K.; Pech, K.; Phelps, P.; Reichhart, L.; Rhyne, C.; Shaw, S.; Shutt, T. A.; Silva, C.; Solovov, V. N.; Sorensen, P.; Stephenson, S.; Sumner, T. J.; Szydagis, M.; Taylor, D. J.; Taylor, W.; Tennyson, B. P.; Terman, P. A.; Tiedt, D. R.; To, W. H.; Tripathi, M.; Tvrznikova, L.; Uvarov, S.; Verbus, J. R.; Webb, R. C.; White, J. T.; Whitis, T. J.; Witherell, M. S.; Wolfs, F. L. H.; Yazdani, K.; Young, S. K.; Zhang, C.
2018-01-01
The Large Underground Xenon (LUX) experiment operates at the Sanford Underground Research Facility to detect nuclear recoils from the hypothetical Weakly Interacting Massive Particles (WIMPs) on a liquid xenon target. Liquid xenon typically contains trace amounts of the noble radioactive isotopes 85Kr and 39Ar that are not removed by the in situ gas purification system. The decays of these isotopes at concentrations typical of research-grade xenon would be a dominant background for a WIMP search experiment. To remove these impurities from the liquid xenon, a chromatographic separation system based on adsorption on activated charcoal was built. 400 kg of xenon was processed, reducing the average concentration of krypton from 130 ppb to 3.5 ppt as measured by a cold-trap assisted mass spectroscopy system. A 50 kg batch spiked to 0.001 g/g of krypton was processed twice and reduced to an upper limit of 0.2 ppt.
High-energy krypton fluoride lasers for inertial fusion.
Obenschain, Stephen; Lehmberg, Robert; Kehne, David; Hegeler, Frank; Wolford, Matthew; Sethian, John; Weaver, James; Karasik, Max
2015-11-01
Laser fusion researchers have realized since the 1970s that the deep UV light from excimer lasers would be an advantage as a driver for robust high-performance capsule implosions for inertial confinement fusion (ICF). Most of this research has centered on the krypton-fluoride (KrF) laser. In this article we review the advantages of the KrF laser for direct-drive ICF, the history of high-energy KrF laser development, and the present state of the art and describe a development path to the performance needed for laser fusion and its energy application. We include descriptions of the architecture and performance of the multi-kilojoule Nike KrF laser-target facility and the 700 J Electra high-repetition-rate KrF laser that were developed at the U.S. Naval Research Laboratory. Nike and Electra are the most advanced KrF lasers for inertial fusion research and energy applications.
The pair correlation function of krypton in the critical region: theory and experiment
NASA Astrophysics Data System (ADS)
Barocchi, F.; Chieux, P.; Fontana, R.; Magli, R.; Meroni, A.; Parola, A.; Reatto, L.; Tau, M.
1997-10-01
We present the results of high-precision measurements of the structure factor S(k) of krypton in the near-critical region of the liquid - vapour phase transition for values of k ranging from 1.5 up to 0953-8984/9/42/003/img15. The experimental results are compared with a theoretical calculation based on the hierarchical reference theory (HRT) with an accurate potential which includes two- and three-body contributions. The theory is based on a new implementation of HRT in which we avoid the use of hard spheres as a reference system. With this soft-core formulation we find a generally good agreement with experiments both at large k, where S(k) probes the short-range correlations, as well as at small k, where critical fluctuations become dominant. Also, for the density derivative of the pair correlation function there is an overall good agreement between theory and experiment.
NASA Astrophysics Data System (ADS)
Serpell, Christopher J.; Rutte, Reida N.; Geraki, Kalotina; Pach, Elzbieta; Martincic, Markus; Kierkowicz, Magdalena; de Munari, Sonia; Wals, Kim; Raj, Ritu; Ballesteros, Belén; Tobias, Gerard; Anthony, Daniel C.; Davis, Benjamin G.
2016-10-01
The desire to study biology in situ has been aided by many imaging techniques. Among these, X-ray fluorescence (XRF) mapping permits observation of elemental distributions in a multichannel manner. However, XRF imaging is underused, in part, because of the difficulty in interpreting maps without an underlying cellular `blueprint' this could be supplied using contrast agents. Carbon nanotubes (CNTs) can be filled with a wide range of inorganic materials, and thus can be used as `contrast agents' if biologically absent elements are encapsulated. Here we show that sealed single-walled CNTs filled with lead, barium and even krypton can be produced, and externally decorated with peptides to provide affinity for sub-cellular targets. The agents are able to highlight specific organelles in multiplexed XRF mapping, and are, in principle, a general and versatile tool for this, and other modes of biological imaging.
NASA Astrophysics Data System (ADS)
Buchholz, Max; Grossmann, Frank; Ceotto, Michele
2018-03-01
We present and test an approximate method for the semiclassical calculation of vibrational spectra. The approach is based on the mixed time-averaging semiclassical initial value representation method, which is simplified to a form that contains a filter to remove contributions from approximately harmonic environmental degrees of freedom. This filter comes at no additional numerical cost, and it has no negative effect on the accuracy of peaks from the anharmonic system of interest. The method is successfully tested for a model Hamiltonian and then applied to the study of the frequency shift of iodine in a krypton matrix. Using a hierarchic model with up to 108 normal modes included in the calculation, we show how the dynamical interaction between iodine and krypton yields results for the lowest excited iodine peaks that reproduce experimental findings to a high degree of accuracy.
Chromatographic separation of radioactive noble gases from xenon
Akerib, DS; Araújo, HM; Bai, X; ...
2017-10-31
The Large Underground Xenon (LUX) experiment operates at the Sanford Underground Research Facility to detect nuclear recoils from the hypothetical Weakly Interacting Massive Particles (WIMPs) on a liquid xenon target. Liquid xenon typically contains trace amounts of the noble radioactive isotopesmore » $$^{85}$$Kr and $$^{39}$$Ar that are not removed by the in situ gas purification system. The decays of these isotopes at concentrations typical of research-grade xenon would be a dominant background for a WIMP search exmperiment. To remove these impurities from the liquid xenon, a chromatographic separation system based on adsorption on activated charcoal was built. 400 kg of xenon was processed, reducing the average concentration of krypton from 130 ppb to 3.5 ppt as measured by a cold-trap assisted mass spectroscopy system. A 50 kg batch spiked to 0.001 g/g of krypton was processed twice and reduced to an upper limit of 0.2 ppt.« less
NASA Astrophysics Data System (ADS)
Baksht, E. Kh; Lomaev, Mikhail I.; Rybka, D. V.; Tarasenko, Viktor F.
2006-06-01
The emission properties of a volume nanosecond discharge plasma produced in xenon, krypton and argon at high pressures in a discharge gap with a cathode having a small radius of curvature are studied. Spectra in the range 120-850 nm and amplitude—time characteristics of xenon emission at different regimes and excitation techniques are recorded and analysed. It is shown that upon excitation of the volume discharge initiated by a beam of avalanche electrons, at least 90% of the energy in the spectral range 120-850 nm is emitted by xenon dimers. For xenon at a pressure of 1.2 atm, ~45 mJ of the spontaneous emission energy was obtained in the full solid angle in a pulse with the full width at half-maximum ~130 ns.
The ATTA-Hefei Instrument for Radioactive Noble-gas Dating
NASA Astrophysics Data System (ADS)
Hu, S.; Cheng, C.; Cheng, G.; Sun, Y. R.; Tu, L.; Yang, G.
2013-12-01
Long-lived noble-gas isotopes 85Kr (10.8 y), 39Ar (269 y) and 81Kr (229 ky) are ideal tracers for dating environmental samples such as groundwater and ice. Together with 14C, these nuclides can be used to cover the whole range of 100-106 y. Atom Trap Trace Analysis (ATTA) is an emerging method for the analysis of these isotopes at an isotopic abundance level as low as 10^-16 [1,2]. The ATTA instrument built in Hefei, China, can determine the isotopic abundances of 85Kr and 81Kr with typically 5-10% accuracy using krypton gas samples of a few micro-liters (STP) krypton gas [3]. The krypton gas sample can be extracted from several liters of air using a distillation-chromatograph setup with a typical efficiency of 85%, while the air sample can be extracted from groundwater or ices. The typical sample size for ATTA measurement is 100L groundwater or 40Kg ices. One such ATTA beamline can handle about 100 samples per year. [1] Chen, C. Y. et al. Ultrasensitive isotope trace analyses with a magneto-optical trap. Science 286, 1139-1141 (1999). [2] Jiang, W. et al. 39Ar detection at the 10-16 isotopic abundance level with atom trap trace analysis. Phys. Rev. Lett. 106, 103001 (2011). [3] Yang, G. -M. et al. Analysis of 85Kr: a comparison at the 10-14 level using micro-liter samples, Sci. Rep. 3, 1596 (2013). Relative uncertainty of the determined 85Kr abundance by the ATTA-Hefei instrument.
10 CFR 20.2206 - Reports of individual monitoring.
Code of Federal Regulations, 2011 CFR
2011-01-01
... quantitites: Radionuclide Quantity of radionuclide 1 in curies Cesium-137 1 Cobalt-60 1 Gold-198 100 Iodine-131 1 Iridium-192 10 Krypton-85 1,000 Promethium-147 10 Techetium-99m 1,000 1 The Commission may...
10 CFR 20.2206 - Reports of individual monitoring.
Code of Federal Regulations, 2013 CFR
2013-01-01
... quantitites: Radionuclide Quantity of radionuclide 1 in curies Cesium-137 1 Cobalt-60 1 Gold-198 100 Iodine-131 1 Iridium-192 10 Krypton-85 1,000 Promethium-147 10 Techetium-99m 1,000 1 The Commission may...
NASA Astrophysics Data System (ADS)
Steinfelds, Eric Victor
The topic of this thesis is the development of the Radioisotope Energy Conversion System (RECS) in a project which is utilizing analytical computational assisted design and some experimental Research in the investigation of fluorescers and effective transducers with the appropriate energy range choice for the conversion of energy. It is desirable to increase the efficiency in electrical power from the raw kinetic power available from the radioactive material within radioisotope power generators. A major step in this direction is the development and use of Radioisotope Energy Conversion Systems to supplement and ideally replace Radioactive Thermal Generators (RTG). It is possible to achieve electrical conversion efficiencies exceeding 25% for RECS power devices compared to only 9 percent efficiency for RTG's. The theoretical basis with existent materials for the potential achievability of efficiencies above 25% is documented within this thesis. The fundamental RECS consists of a radioisotope radiative source (C1), a mediating fluorescent gas (C2) which readily absorbs energy from the beta particles (or alpha's) and subsequently emits blue or UV photons, photovoltaic cells (C3) to convert the blue and UV photons into electrical energy [2], and electrical circuitry (C4). Solid State inspired component (C3), due to its theoretical (and attainable) high efficiency, is a large step ahead of the RTG design concept. The radioisotope flux source produces the beta(-) particles or alpha particles. Geometrically, presently, we prefer to have the ambient fluorescent gas surround the radioisotope flux source. Our fluorescer shall be a gas such as Krypton. Our specifically wide band-gap photovoltaic cells shall have gap energies which are slightly less than that of UV photons produced by the fluorescing gas. Diamond and Aluminum Nitride sample materials are good potential choices for photovoltaic cells, as is explained here in. Out of the material examples discussed, the highest electric power to mass ratio is found to be readily attainable with strontium-90 as the radiative source. Krypton-85 is indisputably the most efficient in RECS devices. In the conclusion in chapter VI, suggestions are given on acceptable ways of containing krypton-85 and providing sufficient shielding on deep space probes destined to use krypton-85 powered 'batteries'.
NASA Astrophysics Data System (ADS)
Ahmed Rudwan, M.; Gabriel, S. B.
2002-01-01
Investigation of the discharge characteristics of the T6 hollow cathode operating on several inert Xenon is currently the propellant of choice for gridded ion thrusters. But in order to make deep space missions feasible, an increase in the Specific Impulse (SI) that these thrusters can achieve is necessary. One method of achieving this is to use a propellant with a lower atomic mass (e.g. argon), as the propellant exhaust velocity is inversely proportional to the square root of the propellant mass. However, the feasibility of operating the hollow cathode using these alternative propellants has to be demonstrated. Moreover, interest in decreasing the propellant cost in missions and ground testing (especially life tests) have led to the comprehensive discharge characterisation of several gases that will be presented in this paper. A Kr/Xe mixture in the naturally occurring ratio, for example, could offer a 15 times cost saving when compared to pure xenon and 2-3 times cost saving when compared to pure krypton. The T6 hollow cathode discharge behaviour as well as its initiation characteristics have been studied. The tests were carried out in diode configuration using a T6 hollow cathode with an enclosed keeper design employing xenon, krypton, argon and a Kr/Xe mix. The discharge initiation tests were undertaken with a view to investigate some of the factors thought to influence the starting potential such as mass flow rate and tip temperature. It was found that, for mass flow rates ranging from 0.2-1.1 mg/s and cathode tip temperatures ranging from 900-1300oC, the breakdown potential was less than 50V for argon, less than 25V for krypton, less than 21V for xenon and less than 35V for the Kr/Xe mix. The discharge initiation results were then compared to those obtained by Fearn et al. with a T5 cathode operating on mercury and with a T6 cathode utilising an open keeper design using xenon propellant. The xenon breakdown potentials were found to be lower than those obtained with an open keeper design by as much as 4V. Steady state discharge behaviour was also investigated in a range of operating conditions. Spot to plume mode transitions were observed in argon, krypton and Kr/Xe discharges for the first time.
AIR INFILTRATION MEASUREMENTS USING TRACER GASES: A LITERATURE REVIEW
The report gives results of a literature review of air filtration measurements using tracer gases, including sulfur hexafluoride, hydrogen, carbon monoxide, carbon dioxide, nitrous oxide, and radioactive argon and krypton. Sulfur hexafluoride is the commonest tracer gas of choice...
Code of Federal Regulations, 2013 CFR
2013-01-01
... exceed 10 square centimeters, and the method of measurement. (vii) Degree of access of human beings to... product. (iv) Solubility in water and body fluids of the forms of the byproduct material identified in...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hansen, N.; Tranter, R. S.; Moshammer, K.
The perturbation of the temperature field caused by a quartz sampling probe has been investigated in a fuel-rich low-pressure premixed ethylene/oxygen/argon/krypton flame using X-ray fluorescence. The experiments were performed at the 7-BM beamline at the Advanced Photon Source (APS) at the Argonne National Laboratory where a continuous beam of X-rays at 15 keV was used to excite krypton atoms that were added to the unburnt flame gases in a concentration of 5% (by volume). The resulting krypton X-ray fluorescence at 12.65 keV was collected and the spatially resolved signal was subsequently converted into the local temperature of the imaged spot.more » One and two dimensional scans of the temperature field were obtained by translating the entire flame chamber through a pre-programmed sequence of positions on high precision translation stages and measuring the X-ray fluorescence at each location. Multiple measurements were performed at various separations between the burner surface and probe tip, representing sampling positions from the preheat, reaction, and postflame zones of the low-pressure flame. Distortions of up to 1000 K of the burner-probe centerline flame temperature were found with the tip of the probe in the preheat zone and distortions of up to 500 K were observed with it in the reaction and postflame zones. Furthermore, perturbations of the temperature field have been revealed that radially reach as far as 20 mm from the burner-probe centerline and about 3 mm in front of the probe tip. Finally, these results clearly reveal the limitations of one-dimensional models for predicting flame-sampling experiments and comments are made with regard to model developments and validations based on quantitative speciation data from low-pressure flames obtained via intrusive sampling techniques.« less
49 CFR 171.8 - Definitions and abbreviations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... which dilutes or replaces oxygen normally in the atmosphere. Associate Administrator means the Associate.... Atmospheric gases means air, nitrogen, oxygen, argon, krypton, neon and xenon. Authorized Inspection Agency... consumption by individuals for purposes of personal care or household use. This term also includes drugs and...
NASA Astrophysics Data System (ADS)
Badoni, D.; Bizzarri, M.; Bonaiuto, V.; Checcucci, B.; De Simone, N.; Federici, L.; Fucci, A.; Paoluzzi, G.; Papi, A.; Piccini, M.; Salamon, A.; Salina, G.; Santovetti, E.; Sargeni, F.; Venditti, S.
2014-01-01
The goal of the NA62 experiment at the CERN SPS is the measurement of the Branching Ratio of the very rare kaon decay K+→π+ ν bar nu with a 10% accuracy by collecting 100 events in two years of data taking. An efficient photon veto system is needed to reject the K+→π+ π0 background and a liquid krypton electromagnetic calorimeter will be used for this purpose in the 1-10 mrad angular region. The L0 trigger system for the calorimeter consists of a peak reconstruction algorithm implemented on FPGA by using a mixed parallel architecture based on soft core Altera NIOS II embedded processors together with custom VHDL modules. This solution allows an efficient and flexible reconstruction of the energy-deposition peak. The system will be totally composed of 36 TEL62 boards, 108 mezzanine cards and 215 high-performance FPGAs. We describe the design, current status and the results of the first performance tests.
Energy transfer studies in krypton-xenon mixtures excited in a cooled DC discharge
NASA Astrophysics Data System (ADS)
Krylov, B.; Gerasimov, G.; Morozov, A.; Arnesen, A.; Hallin, R.; Heijkenskjold, F.
2000-01-01
The VUV spectrum of gaseous mixtures of krypton with a small amount of xenon added was investigated in the range 115-200 nm. The mixtures were excited in a capillary DC discharge where the capillary could be cooled by using liquid nitrogen. The mixed molecule band around the Xe I resonance line at λ = 147 nm and the mixed molecule continuum to the long wavelength side from the line were analysed. The band around λ = 147 nm was identified as transitions between a weakly bound excited state and the weakly bound ground state of XeKr molecules. When cooling the capillary wall, the appearance of the Xe2 continuum was observed. The effect is ascribed to energy transfer between molecular states as a consequence of radiation trapping in the band around λ = 147 nm. The role of the mixed molecule in the formation of the VUV spectrum of the gas mixture is discussed and underlined.
NASA Astrophysics Data System (ADS)
Smith, R. Scott; Matthiesen, Jesper; Kay, Bruce D.
2010-03-01
Molecular beam techniques, temperature-programmed desorption (TPD), and reflection absorption infrared spectroscopy (RAIRS) are used to explore the relationship between krypton permeation through and the self-diffusivity of supercooled liquid methanol at temperatures (100-115 K) near the glass transition temperature, Tg (103 K). Layered films, consisting of CH3OH and CD3OH, are deposited on top of a monolayer of Kr on a graphene covered Pt(111) substrate at 25 K. Concurrent Kr TPD and RAIRS spectra are acquired during the heating of the composite film to temperatures above Tg. The CO vibrational stretch is sensitive to the local molecular environment and is used to determine the supercooled liquid diffusivity from the intermixing of the isotopic layers. We find that the Kr permeation and the diffusivity of the supercooled liquid are directly and quantitatively correlated. These results validate the rare-gas permeation technique as a tool for probing the diffusivity of supercooled liquids.
Smith, R Scott; Matthiesen, Jesper; Kay, Bruce D
2010-03-28
Molecular beam techniques, temperature-programmed desorption (TPD), and reflection absorption infrared spectroscopy (RAIRS) are used to explore the relationship between krypton permeation through and the self-diffusivity of supercooled liquid methanol at temperatures (100-115 K) near the glass transition temperature, T(g) (103 K). Layered films, consisting of CH(3)OH and CD(3)OH, are deposited on top of a monolayer of Kr on a graphene covered Pt(111) substrate at 25 K. Concurrent Kr TPD and RAIRS spectra are acquired during the heating of the composite film to temperatures above T(g). The CO vibrational stretch is sensitive to the local molecular environment and is used to determine the supercooled liquid diffusivity from the intermixing of the isotopic layers. We find that the Kr permeation and the diffusivity of the supercooled liquid are directly and quantitatively correlated. These results validate the rare-gas permeation technique as a tool for probing the diffusivity of supercooled liquids.
Threshold krypton charge-state distributions coincident with K-shell fluorescence.
NASA Astrophysics Data System (ADS)
Armen, Brad; Levin, Jon; Kanter, Elliot; Krässig, Bertold; Southworth, Steve; Young, Linda
2001-05-01
The distribution of Kr^q+ ionic charge states has been measured in coincidence with K-shell photon emission as a function of incident-photon energy across the krypton 1s threshold. With this scheme, we observe changes resulting from the contrast between resonant Raman and fluorescence effects. By selecting the radiative(U. Arp, T. LeBrun, S. H. Southworth, M. A. MacDonald, and M. Jung, Phys. Rev.) A 51 3598 (1995), as opposed to the non-radiative(G. B. Armen, J. C. Levin, and I. A. Sellin, Phys. Rev.) A 53 772 (1996) channel, excitation PCI effects are suppressed. In general, the higher charge states are seen to increase in importance as the edge is traversed. We present the experimental results in detail and an interpretation of the observed trends, based on a simple model of the excitation processfootnoteÅberg and Tulkki, in Atomic Inner-Shell Physics ed. B. Crasemann, Plenum 1985 and the ensuing cascade decay.
Volatile inventory of Mars-2: Primordial sources and fractionating processes
NASA Technical Reports Server (NTRS)
Pepin, R. O.
1987-01-01
The total volatile inventory of Mars has been modeled using meteoritic and presumed primordial abundances in the early solar system. Evidence is presented which indicates that the elemental abundances of the noble gases on Earth and Mars are similar, and their ratios are comparable to those in average carbonaceous chondrites with the exception of xenon and krypton. In order to account for presently observed variations in gas abundances, two primordial sources were used. One was the solar composition similar to the solar wind, and the other of carbonaceous grains that were the source for trace exotic components. For Mars, a model in which the early, high solar EUV flux with continued hydrogen production by differentiation results in mass fractionation of the primordial atmosphere, early depletion of xenon, and later depletion of gases lighter than krypton. The result is that the primordial Mars water inventory may have been on the order of 20 to 30 km if spread over the planet.
Development of a mass spectrometer system for the measurement of inert gases in meteorites
NASA Technical Reports Server (NTRS)
Palma, R. L.
1983-01-01
The study of the inert gases in meteorites has provided many clues as to the origin and evolution of the solar system. Particularly crucial and complex are the gases krypton and xenon. To accurately measure the isotopic compositions of these gases requires a mass spectrometer of high sensitivity and resolution. A previously unused and largely untested mass spectrometer system was brought to the point where it was ready for routine sample analyses. This involved, among other things, focusing the ion beam for optimal peak shape and sensitivity, documenting the instrument's response to a series of characteristic tests such as multplier gain checks, and interfacing the instrument to a computer to run the sample analyses. Following this testing and setting up, three iron meteorite samples were to be analyzed for argon, krypton, and xenon. The three samples were shown in prior work to possibly contain primordial heavy inert gases. Although these analyses have not yet been carried out, it is anticipated that they will be completed in the near future.
Collisional Dynamics of the Cesium D1 and D2 Transitions
2010-09-01
37 14. Comparison of Phase Changing Probability and Polarizability ...Phase Changing Probability and Polarizability for D2 Transition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 25...theoretically determined the values for broadening and shift rates for cesium with Argon , Krypton, and Xenon from the interatomic potentials [27]. The rates
Tests of Transport Theory and Reduced Impurity Influx with Highly Radiative Plasmas in TFTR
NASA Astrophysics Data System (ADS)
Hill, K. W.
1997-11-01
The electron and ion temperature profiles in beam-heated plasmas were observed to be remarkably invariant when radiative losses were increased significantly through gas puffing of high-Z impurities (argon, krypton, xenon) in the Tokamak Fusion Test Reactor. Without impurity puffing, radiative losses accounted for typically only ~ 25\\char'45 of the input power and the radiation profile was strongly peaked at the plasma edge, where the dominant carbon impurity was not fully stripped. At central electron temperatures, T_eo, of ~ 6 keV, trace concentrations of krypton and xenon (n_z/ne ~ 10-3) generated flat and centrally peaked radiation profiles respectively, and a significant fraction of the input power (45-100\\char'45 ) was lost through radiation. This loss provided a nearly ideal technique for studying local heat transport in tokamaks because it perturbed the net heating profile strongly and in a measureable way, with little effect on the density and the beam deposition profiles. In supershot plasmas, Ti >> T_e, the ion temperature profile remained constant, or even increased modestly, as the radiated power fraction was increased to 75-90\\char'45 with krypton and xenon. This observation is surprising because ion-electron coupling is the dominant power loss term for the ions in the core of supershot plasmas, and the central Ti would have decreased a factor of two if the local ion thermal diffusivity had remained constant at its value without impurity puffing. In L-mode plasmas where ion-electron power coupling is a smaller term in the power balance, the electron temperature during impurity puffing also changed only ~ 10-15\\char'45 even as the net power flow through the electrons was decreased by a factor of ~ 3. The ``stiffness" of the temperature profiles to net input power is supportive of transport mechanisms which have a marginal-stability character. Preliminary comparisons of the temperature changes with predictions of the IFS/PPPL transport model,(M. Kotschenreuther, W. Dorland, M. A. Beer, and G. W. Hammett, Phys. Plasmas 2, 2381 (1995)) which has strong marginal-stability behavior, are reasonable; more detailed comparisons are in progress. Use of high-Z radiators did not impair fusion performance, confirming they can be used to reduce the heat flux to the plasma facing components with minimal ion dilution. At input power level s of 30-33 MW, enhanced radiation through krypton and xenon puffing eliminated serious carbon influx (carbon ``blooms") which occurred in comparable plasmas without impurity puffing.
Ultra-high sensitivity radiation detection apparatus and method
Gross, Kenneth C.; Valentine, John D.; Markum, Francis; Zawadzki, Mary; Dickerman, Charles
1999-01-01
A method and apparatus are provided to concentrate and detect very low levels of radioactive noble gases from the atmosphere. More specifically the invention provides a method and apparatus to concentrate xenon, krypton and radon in an organic fluid and to detect these gases by the radioactive emissions.
49 CFR 178.337-8 - Openings, inlets, and outlets.
Code of Federal Regulations, 2011 CFR
2011-10-01
... used to transport chlorine. The requirements for inlets and outlets on chlorine cargo tanks are in... dioxide, helium, krypton, neon, nitrogen, and xenon, or mixtures thereof. (6) In addition to the internal... equalization of pressure. (b) Inlets and discharge outlets on chlorine tanks. The inlet and discharge outlets...
49 CFR 178.337-8 - Openings, inlets, and outlets.
Code of Federal Regulations, 2010 CFR
2010-10-01
... used to transport chlorine. The requirements for inlets and outlets on chlorine cargo tanks are in... dioxide, helium, krypton, neon, nitrogen, and xenon, or mixtures thereof. (6) In addition to the internal... equalization of pressure. (b) Inlets and discharge outlets on chlorine tanks. The inlet and discharge outlets...
APPARENT 85KRYPTON AGES OF GROUNDWATER WITHIN THE ROYAL WATERSHED, MAINE, USA
85Kr activities were determined in 264 domestic and municipal wells from 2002-2004 in the Royal watershed (361 km2), Maine. Gas extraction for 85Kr from wells was effected directly via a well-head methodology permitting efficient widespread analys...
ERIC Educational Resources Information Center
Fuller, C. A.
A breadboard model of a laser display system is described in detail and its operating procedure is outlined. The system consists of: a Model 52 argon krypton ion laser and power supply; an optical breadboard comprising a pocket cell light modulator, a galvonmeter beam deflector for vertical scanning, a unique multiple reflection beam steerer for…
49 CFR 178.338-11 - Discharge control devices.
Code of Federal Regulations, 2010 CFR
2010-10-01
... devices. (a) Excess-flow valves are not required. (b) Each liquid filling and liquid discharge line must... tank that is used to transport argon, carbon dioxide, helium, krypton, neon, nitrogen, xenon, or mixtures thereof, each liquid filling and liquid discharge line must be provided with an on-vehicle...
Method and apparatus for filling thermal insulating systems
Arasteh, Dariush K.
1992-01-01
A method for filling insulated glazing units is disclosed. The method utilizes a vacuum chamber in which the insulated glazing units are placed. The insulated glazing units and vacuum chamber are evacuated simultaneously. The units are then refilled with a low conductance gas such as Krypton while the chamber is simultaneously refilled with air.
Krypton and xenon in lunar fines
NASA Technical Reports Server (NTRS)
Basford, J. R.; Dragon, J. C.; Pepin, R. O.; Coscio, M. R., Jr.; Murthy, V. R.
1973-01-01
Data from grain-size separates, stepwise-heated fractions, and bulk analyses of 20 samples of fines and breccias from five lunar sites are used to define three-isotope and ordinate intercept correlations in an attempt to resolve the lunar heavy rare gas system in a statistically valid approach. Tables of concentrations and isotope compositions are given.
Code of Federal Regulations, 2011 CFR
2011-01-01
... promethium-147: Requirements for license to manufacture, process, produce, or initially transfer. 32.22 Section 32.22 Energy NUCLEAR REGULATORY COMMISSION SPECIFIC DOMESTIC LICENSES TO MANUFACTURE OR TRANSFER..., or initially transfer. (a) An application for a specific license to manufacture, process, or produce...
Electrodeless discharge lamp is easily started, has high stability
NASA Technical Reports Server (NTRS)
Bell, W. E.; Bloom, A. L.
1966-01-01
Electrodeless discharge borosilicate glass lamp is used in various high-resolution optical systems. It is partially charged with krypton, contains small amounts of rubidium, and is enclosed in a hermetically sealed envelope that maintains the lamp at an optimum temperature during discharge. The lamp is quickly started by its excitation coil.
Development of Electron Beam Pumped KrF Lasers for Fusion Energy
2008-01-01
Direct drive with krypton fluoride (KrF) lasers is an attractive approach to inertial fusion energy (IFE): KrF lasers have outstanding beam spatial...attractive power plant [3]. In view of these advances, several world-wide programs are underway to develop KrF lasers for fusion energy . These include
Ar-Xe Laser: The Path to a Robust, All-Electric Shipboard Directed Energy Weapon
2008-12-18
Krypton Fluoride (KrF) laser for fusion energy and is sponsored by the Department of Energy’s (DOE) High Average Power Laser (HAPL) program. DOE...Electronics Conference, Arlington VA, October 2007. 9. “Electron Beam Pumped Lasers for Fusion Energy and Directed Energy Applications”, presented by
Zhao, Yanying; Gong, Yu; Chen, Mohua; Ding, Chuanfan; Zhou, Mingfei
2005-12-29
The combination of matrix isolation infrared spectroscopic and quantum chemical calculation results provide strong evidence that scandium and yttrium monoxide cations, ScO+ and YO+, coordinate multiple noble gas atoms in forming noble gas complexes. The results showed that ScO+ coordinates five Ar, Kr, or Xe atoms, and YO+ coordinates six Ar or Kr and five Xe atoms in solid noble gas matrixes. Hence, the ScO+ and YO+ cations trapped in solid noble gas matrixes should be regarded as the [ScO(Ng)5]+ (Ng = Ar, Kr, or Xe), [YO(Ng)6]+ (Ng = Ar or Kr) or [YO(Xe)5]+ complexes. Experiments with dilute krypton or xenon in argon or krypton in xenon produced new IR bands, which are due to the stepwise formation of the [ScO(Ar)(5-n)(Kr)n]+, [ScO(Kr)(5-n)(Xe)n]+ (n = 1-5), [YO(Ar)(6-n)(Kr)n]+ (n = 1-6), and [YO(Ar)(6-n)(Xe)n]+ (n = 1-4) complexes.
Analysis of 85Kr: a comparison at the 10-14 level using micro-liter samples
Yang, G. -M.; Cheng, C. -F.; Jiang, W.; Lu, Z. -T.; Purtschert, R.; Sun, Y. -R.; Tu, L. -Y.; Hu, S. -M.
2013-01-01
The isotopic abundance of 85Kr in the atmosphere, currently at the level of 10−11, has increased by orders of magnitude since the dawn of nuclear age. With a half-life of 10.76 years, 85Kr is of great interest as tracers for environmental samples such as air, groundwater and ice. Atom Trap Trace Analysis (ATTA) is an emerging method for the analysis of rare krypton isotopes at isotopic abundance levels as low as 10−14 using krypton gas samples of a few micro-liters. Both the reliability and reproducibility of the method are examined in the present study by an inter-comparison among different instruments. The 85Kr/Kr ratios of 12 samples, in the range of 10−13 to 10−10, are measured independently in three laboratories: a low-level counting laboratory in Bern, Switzerland, and two ATTA laboratories, one in Hefei, China, and another in Argonne, USA. The results are in agreement at the precision level of 5%. PMID:23549244
A study of single and binary ion plasma expansion into laboratory-generated plasma wakes
NASA Technical Reports Server (NTRS)
Wright, Kenneth Herbert, Jr.
1988-01-01
Plasma expansion into the wake of a large rectangular plate immersed in a collisionless, supersonic plasma was investigated in laboratory experiments. The experimental conditions address both single ion and binary ion plasma flows for the case of a body whose size is large in comparison with the Debye length, when the potential difference between the body and the plasma is relatively small. A new plasma source was developed to generate equi-velocity, binary ion plasma flows, which allows access to new parameter space that have previously been unavailable for laboratory studies. Specifically, the new parameters are the ionic mass ratio and the ionic component density ratio. In a series of experiments, a krypton-neon plasma is employed where the ambient density ratio of neon to krypton is varied more than an order of magnitude. The expansion in both the single ion and binary ion plasma cases is limited to early times, i.e., a few ion plasma periods, by the combination of plasma density, plasma drift speed, and vacuum chamber size, which prevented detailed comparison with self-similar theory.
Design and construction of a home-made and cheaper argon arc lamp
NASA Astrophysics Data System (ADS)
Sabaeian, Mohammad; Nazari-Tarkarani, Zeinab; Ebrahimzadeh, Azadeh
2018-05-01
The authors report on the design and construction of an argon arc lamp which provides noticeably a cheaper instrument for laser and medical applications. Cesium-doped tungsten and pure tungsten rods were used, respectively, for the lamp cathode and anode. To seal the glassy tube, a 50-50 Fe-Ni alloy was successfully used as a medium to attach the tungsten electrodes to the borosilicate glass tube. Starting voltage of the lamp versus the gas pressure, operation voltage-current diagram at various gas pressures, and lamp spectrum in the various pressures were measured. A comparison was made with krypton arc lamp. The lamp operation was satisfactory without any crack or fracture during lightening operation. The results showed that the lamp-lightening threshold voltage depends linearly on the pressure and arc length in such a way that there is an increase in the voltage by raising these two parameters. We have also observed that by increasing the argon pressure, there is a shifting in emission spectrum from the ultraviolet to the visible region. Comparison with krypton arc lamp indicated that argon lamp needs a higher threshold lightening voltage.
NASA Astrophysics Data System (ADS)
Ma, T.; Chen, H.; Patel, P. K.; Schneider, M.; Barrios, M.; Berzak Hopkins, L.; Casey, D.; Chung, H.-K.; Hammel, B.; Jarrott, C.; Nora, R.; Pak, A.; Scott, H.; Spears, B.; Weber, C.
2015-11-01
The inference of ion temperature from neutron spectral measurements in indirect-drive ICF implosions is known to be sensitive to non-thermal velocity distributions in the fuel. The electron temperature (Te) inferred from dopant line ratios should not be sensitive to these bulk motions and hence may be a better measure of the thermal temperature of the hot spot. Here we describe a series of experiments to be conducted on the NIF where a small concentration of a mid-Z dopant (Krypton) is added to the fuel gas. The x-ray spectra is measured and the electron temperature is inferred from Kr line ratios. We also quantify the level of radiative cooling in the hot spot due to this mid-Z dopant. These experiments represent the first direct measurement of hot spot Te using spectroscopy, and we will describe the considerations for applying x-ray spectroscopy in such dense and non-uniform hot spots. This work performed under the auspices of U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.
Optical pulse characteristics of sonoluminescence at low acoustic drive levels.
Arakeri, V H; Giri, A
2001-06-01
From a nonaqueous alkali-metal salt solution, it is possible to observe sonoluminescence (SL) at low acoustic drive levels with the ratio of the acoustic pressure amplitude to the ambient pressure being about 1. In this case, the emission has a narrowband spectral content and consists of a few flashes of light from a levitated gas bubble going through an unstable motion. A systematic statistical study of the optical pulse characteristics of this form of SL is reported here. The results support our earlier findings [Phys. Rev. E 58, R2713 (1998)], but in addition we have clearly established a variation in the optical pulse duration with certain physical parameters such as the gas thermal conductivity. Quantitatively, the SL optical pulse width is observed to vary from 10 ns to 165 ns with the most probable value being 82 ns, for experiments with krypton-saturated sodium salt ethylene glycol solution. With argon, the variation is similar to that of krypton but the most probable value is reduced to 62 ns. The range is significantly smaller with helium, being from 22 ns to 65 ns with the most probable value also being reduced to 42 ns. The observed large variation, for example with krypton, under otherwise fixed controllable experimental parameters indicates that it is an inherent property of the observed SL process, which is transient in nature. It is this feature that necessitated our statistical study. Numerical simulations of the SL process using the bubble dynamics approach of Kamath, Prosperetti, and Egolfopoulos [J. Acoust. Soc. Am. 94, 248 (1993)] suggest that a key uncontrolled parameter, namely the initial bubble radius, may be responsible for the observations. In spite of the fact that certain parameters in the numerical computations have to be fixed from a best fit to one set of experimental data, the observed overall experimental trends of optical pulse characteristics are predicted reasonably well.
Optical pulse characteristics of sonoluminescence at low acoustic drive levels
NASA Astrophysics Data System (ADS)
Arakeri, Vijay H.; Giri, Asis
2001-06-01
From a nonaqueous alkali-metal salt solution, it is possible to observe sonoluminescence (SL) at low acoustic drive levels with the ratio of the acoustic pressure amplitude to the ambient pressure being about 1. In this case, the emission has a narrowband spectral content and consists of a few flashes of light from a levitated gas bubble going through an unstable motion. A systematic statistical study of the optical pulse characteristics of this form of SL is reported here. The results support our earlier findings [Phys. Rev. E 58, R2713 (1998)], but in addition we have clearly established a variation in the optical pulse duration with certain physical parameters such as the gas thermal conductivity. Quantitatively, the SL optical pulse width is observed to vary from 10 ns to 165 ns with the most probable value being 82 ns, for experiments with krypton-saturated sodium salt ethylene glycol solution. With argon, the variation is similar to that of krypton but the most probable value is reduced to 62 ns. The range is significantly smaller with helium, being from 22 ns to 65 ns with the most probable value also being reduced to 42 ns. The observed large variation, for example with krypton, under otherwise fixed controllable experimental parameters indicates that it is an inherent property of the observed SL process, which is transient in nature. It is this feature that necessitated our statistical study. Numerical simulations of the SL process using the bubble dynamics approach of Kamath, Prosperetti, and Egolfopoulos [J. Acoust. Soc. Am. 94, 248 (1993)] suggest that a key uncontrolled parameter, namely the initial bubble radius, may be responsible for the observations. In spite of the fact that certain parameters in the numerical computations have to be fixed from a best fit to one set of experimental data, the observed overall experimental trends of optical pulse characteristics are predicted reasonably well.
2D-imaging of sampling-probe perturbations in laminar premixed flames using Kr X-ray fluorescence
Hansen, N.; Tranter, R. S.; Moshammer, K.; ...
2017-04-14
The perturbation of the temperature field caused by a quartz sampling probe has been investigated in a fuel-rich low-pressure premixed ethylene/oxygen/argon/krypton flame using X-ray fluorescence. The experiments were performed at the 7-BM beamline at the Advanced Photon Source (APS) at the Argonne National Laboratory where a continuous beam of X-rays at 15 keV was used to excite krypton atoms that were added to the unburnt flame gases in a concentration of 5% (by volume). The resulting krypton X-ray fluorescence at 12.65 keV was collected and the spatially resolved signal was subsequently converted into the local temperature of the imaged spot.more » One and two dimensional scans of the temperature field were obtained by translating the entire flame chamber through a pre-programmed sequence of positions on high precision translation stages and measuring the X-ray fluorescence at each location. Multiple measurements were performed at various separations between the burner surface and probe tip, representing sampling positions from the preheat, reaction, and postflame zones of the low-pressure flame. Distortions of up to 1000 K of the burner-probe centerline flame temperature were found with the tip of the probe in the preheat zone and distortions of up to 500 K were observed with it in the reaction and postflame zones. Furthermore, perturbations of the temperature field have been revealed that radially reach as far as 20 mm from the burner-probe centerline and about 3 mm in front of the probe tip. Finally, these results clearly reveal the limitations of one-dimensional models for predicting flame-sampling experiments and comments are made with regard to model developments and validations based on quantitative speciation data from low-pressure flames obtained via intrusive sampling techniques.« less
Harris, Katie; Armstrong, Scott P; Campos-Pires, Rita; Kiru, Louise; Franks, Nicholas P; Dickinson, Robert
2013-11-01
Xenon, the inert anesthetic gas, is neuroprotective in models of brain injury. The authors investigate the neuroprotective mechanisms of the inert gases such as xenon, argon, krypton, neon, and helium in an in vitro model of traumatic brain injury. The authors use an in vitro model using mouse organotypic hippocampal brain slices, subjected to a focal mechanical trauma, with injury quantified by propidium iodide fluorescence. Patch clamp electrophysiology is used to investigate the effect of the inert gases on N-methyl-D-aspartate receptors and TREK-1 channels, two molecular targets likely to play a role in neuroprotection. Xenon (50%) and, to a lesser extent, argon (50%) are neuroprotective against traumatic injury when applied after injury (xenon 43±1% protection at 72 h after injury [N=104]; argon 30±6% protection [N=44]; mean±SEM). Helium, neon, and krypton are devoid of neuroprotective effect. Xenon (50%) prevents development of secondary injury up to 48 h after trauma. Argon (50%) attenuates secondary injury, but is less effective than xenon (xenon 50±5% reduction in secondary injury at 72 h after injury [N=104]; argon 34±8% reduction [N=44]; mean±SEM). Glycine reverses the neuroprotective effect of xenon, but not argon, consistent with competitive inhibition at the N-methyl-D-aspartate receptor glycine site mediating xenon neuroprotection against traumatic brain injury. Xenon inhibits N-methyl-D-aspartate receptors and activates TREK-1 channels, whereas argon, krypton, neon, and helium have no effect on these ion channels. Xenon neuroprotection against traumatic brain injury can be reversed by increasing the glycine concentration, consistent with inhibition at the N-methyl-D-aspartate receptor glycine site playing a significant role in xenon neuroprotection. Argon and xenon do not act via the same mechanism.
NASA Technical Reports Server (NTRS)
1989-01-01
Rayovac Corporation's Luma 2 flashlight incorporates NASA's systems redundancy. The company also received assistance from NERAC. The flashlight has an extra-bright Super Krypton primary bulb and an independent backup system including a separate lithium power cell (a NASA developed technology), its own bulb and switch with corrosion proof sealed contacts. NERAC has also assisted Rayovac in developing other products.
The Chemistry of the Noble Gases, Understanding the Atom Series.
ERIC Educational Resources Information Center
Chernick, Cedric L.
The history of the discovery, isolation, characterization, production and use of argon, krypton, xenon, helium, and radon is followed by an account of early attempts to react them with other elements. The use of the electron shell theory of valence to explain their inertness and the reactions of chemists to the production of xenon compounds is…
Method and apparatus for filling thermal insulating systems
Arasteh, D.K.
1992-01-14
A method for filling insulated glazing units is disclosed. The method utilizes a vacuum chamber in which the insulated glazing units are placed. The insulated glazing units and vacuum chamber are evacuated simultaneously. The units are then refilled with a low conductance gas such as Krypton while the chamber is simultaneously refilled with air. 3 figs.
Tables Of Gaussian-Type Orbital Basis Functions
NASA Technical Reports Server (NTRS)
Partridge, Harry
1992-01-01
NASA technical memorandum contains tables of estimated Hartree-Fock wave functions for atoms lithium through neon and potassium through krypton. Sets contain optimized Gaussian-type orbital exponents and coefficients, and near Hartree-Fock quality. Orbital exponents optimized by minimizing restricted Hartree-Fock energy via scaled Newton-Raphson scheme in which Hessian evaluated numerically by use of analytically determined gradients.
NASA Astrophysics Data System (ADS)
Niemann, H. B.; Haberman, J. A.; Harpold, D. N.; Hartle, R. E.; Kasprzak, W. T.; Mahaffy, P. R.; Atreya, S. K.; Carignan, G. R.; Donahue, T. M.; Hunten, D. M.; Owen, T. C.; Spencer, N. W.
1996-09-01
The chemical and isotopic composition of the Jovian atmosphere was measured by the Galileo Probe Mass Spectrometer (GPMS). This data was obtained on December 7, 1995 over a time period of approximately 1 hour during the probe descent in the 0.5 to 20 bar pressure region and transmitted to Earth over a period of several weeks. The sampling was either of atmospheric gases directly introduced into the ion source of the mass spectrometer through one of 2 capillary leak arrays or of gas which had been processed in enrichment cells to enhance the sensitivity of the measurement to trace species or heavy noble gases. Mixing ratios or limits were previously reported [Niemann et al., 1996] for atmospheric hydrogen, helium, methane, water, ammonia, hydrogen sulfide, neon, argon, krypton, and xenon. Ratios for isotopes of He, Ne, Ar, Kr, Xe, C, and H were also obtained. Additional molecules detected at the present stage of analysis include ethane, ethylene, propane, and hydrogen chloride as well as benzene and carbon/nitrogen compounds. The GPMS Flight Unit was not calibrated for some of these molecules and laboratory studies continue on an Engineering Unit. A substantial increase was observed in the mixing ratio of water, hydrogen sulfide, ethane and other species with increasing depth into the atmosphere over the 8 bar to 23 bar pressure regime. It has been suggested [Atreya et al., 1996] that the lower than expected abundance of many species in the early part of the descent and the observed increase with depth may be the signature of a large downdraft. H. B. Niemann et al., Science 272, 781 (1996). S. K. Atreya et al., Paper presented at the European Geophysical Society Meeting, The Hague, Netherlands, May 6, 1996, EGS Bull. 58, 197 (1996).
Ramsey-type spectroscopy in the XUV spectral region
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pirri, A.; European Laboratory for Nonlinear Spectroscopy, Via N. Carrara 1, I-50019 Sesto Fiorentino; Sali, E.
2010-02-02
We report an experimental and theoretical investigation of Ramsey-type spectroscopy with high-order harmonic generation applied to autoionizing states of Krypton. The ionization yield, detected by an ion-mass spectrometer, shows the characteristic quantum interference pattern. The behaviour of the fringe contrast was interpreted on the basis of a simple analytic model, which reproduces the experimental data without any free parameter.
Single-photon ultrashort-lived radionuclides: symposium proceedings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paras, P.; Thiessen, J.W.
1985-01-01
The purpose was to define the current role and state-of-the-art regarding the development, clinical applications, and usefulness of generator-produced single-photon ultrashort-lived radionuclides (SPUSLR's) and to predict their future impact on medicine. Special emphasis was placed on the generator production of iridium-191, gold-195, and krypton-81. This report contains expanded summaries of the included papers. (ACR)
A Performance and Plume Comparison of Xenon and Krypton Propellant on the SPT-100
2012-07-20
2 2 )sin()cos()()( )cos( dvmr vmT mvm dvvf vdvvf v )( )( 2/ 2/ 2 2/ 2/ 2 )sin()( )sin()()( dmr
First Detection of Krypton and Xenon in a White Dwarf
NASA Astrophysics Data System (ADS)
Werner, Klaus; Rauch, Thomas; Ringat, Ellen; Kruk, Jeffrey W.
2012-07-01
We report on the first detection of the noble gases krypton (Z = 36) and xenon (54) in a white dwarf. About 20 Kr VI- VII and Xe VI- VII lines were discovered in the ultraviolet spectrum of the hot DO-type white dwarf RE 0503-289. The observations, performed with the Far Ultraviolet Spectroscopic Explorer, also reveal highly ionized photospheric lines from other trans-iron group elements, namely Ga (31), Ge (32), As (33), Se (34), Mo (42), Sn (50), Te (52), and I (53), from which gallium and molybdenum are new discoveries in white dwarfs, too. For Kr and Xe, we performed an NLTE analysis and derived mass fractions of log Kr = -4.3 ± 0.5 and log Xe = -4.2 ± 0.6, corresponding to an enrichment by factors of 450 and 3800, respectively, relative to the Sun. The origin of the large overabundances is unclear. We discuss the roles of neutron-capture nucleosynthesis in the precursor star and radiation-driven diffusion. It is possible that diffusion is insignificant and that the observed metal abundances constrain the evolutionary history of the star. Its hydrogen deficiency may be the consequence of a late helium-shell flash or a binary white dwarf merger.
Antiapoptotic activity of argon and xenon
Spaggiari, Sabrina; Kepp, Oliver; Rello-Varona, Santiago; Chaba, Kariman; Adjemian, Sandy; Pype, Jan; Galluzzi, Lorenzo; Lemaire, Marc; Kroemer, Guido
2013-01-01
Although chemically non-reactive, inert noble gases may influence multiple physiological and pathological processes via hitherto uncharacterized physical effects. Here we report a cell-based detection system for assessing the effects of pre-defined gas mixtures on the induction of apoptotic cell death. In this setting, the conventional atmosphere for cell culture was substituted with gas combinations, including the same amount of oxygen (20%) and carbon dioxide (5%) but 75% helium, neon, argon, krypton, or xenon instead of nitrogen. The replacement of nitrogen with noble gases per se had no effects on the viability of cultured human osteosarcoma cells in vitro. Conversely, argon and xenon (but not helium, neon, and krypton) significantly limited cell loss induced by the broad-spectrum tyrosine kinase inhibitor staurosporine, the DNA-damaging agent mitoxantrone and several mitochondrial toxins. Such cytoprotective effects were coupled to the maintenance of mitochondrial integrity, as demonstrated by means of a mitochondrial transmembrane potential-sensitive dye and by assessing the release of cytochrome c into the cytosol. In line with this notion, argon and xenon inhibited the apoptotic activation of caspase-3, as determined by immunofluorescence microscopy coupled to automated image analysis. The antiapoptotic activity of argon and xenon may explain their clinically relevant cytoprotective effects. PMID:23907115
The Liquid Krypton Hugoniot at Megabar Pressures
NASA Astrophysics Data System (ADS)
Root, Seth; Magyar, Rudy J.; Mattsson, Ann E.; Hanson, David L.; Mattsson, Thomas R.
2011-06-01
Krypton is an ideal candidate to study multi-Mbar pressure effects on elements with filled-shell electron configurations. Few experimental data on Kr at high pressures exist, however, with prior Hugoniot data limited to below 1 Mbar. Similar to liquid xenon, the current Kr equation of state (EOS) models agree with the data and each other below 1 Mbar, but diverge with increasing pressure. We examine the liquid Kr Hugoniot up to 8 Mbar by using density functional theory (DFT) methods and by performing shock compression experiments on the Sandia Z - accelerator. Our initial DFT Kr Hugoniot calculations indicated the standard PAW potential is inadequate at the high pressures and temperatures occurring under strong shock compression. A new Kr PAW potential was constructed giving improved scattering properties of the atom at high energies. The Z Hugoniot measurements above 1 Mbar validated the DFT results and the pseudo-potential. The DFT and Z results suggest that the current EOS models require some modifications. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Company, for the U. S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.
1998-07-01
to a hydrodynamic expansion of the so-called " nanoplasma " into the vacuum. The relative weight of each of these two explosion mechanisms depends on... nanoplasma . In particular, we observe L-shell emission in the case of Krypton and Xenon clusters and K-shell emission for Argon. Our results concern the
Radiation Effects on DC-DC Converters
NASA Technical Reports Server (NTRS)
Zhang, De-Xin; AbdulMazid, M. D.; Attia, John O.; Kankam, Mark D. (Technical Monitor)
2001-01-01
In this work, several DC-DC converters were designed and built. The converters are Buck Buck-Boost, Cuk, Flyback, and full-bridge zero-voltage switched. The total ionizing dose radiation and single event effects on the converters were investigated. The experimental results for the TID effects tests show that the voltages of the Buck Buck-Boost, Cuk, and Flyback converters increase as total dose increased when using power MOSFET IRF250 as a switching transistor. The change in output voltage with total dose is highest for the Buck converter and the lowest for Flyback converter. The trend of increase in output voltages with total dose in the present work agrees with those of the literature. The trends of the experimental results also agree with those obtained from PSPICE simulation. For the full-bridge zero-voltage switch converter, it was observed that the dc-dc converter with IRF250 power MOSFET did not show a significant change of output voltage with total dose. In addition, for the dc-dc converter with FSF254R4 radiation-hardened power MOSFET, the output voltage did not change significantly with total dose. The experimental results were confirmed by PSPICE simulation that showed that FB-ZVS converter with IRF250 power MOSFET's was not affected with the increase in total ionizing dose. Single Event Effects (SEE) radiation tests were performed on FB-ZVS converters. It was observed that the FB-ZVS converter with the IRF250 power MOSFET, when the device was irradiated with Krypton ion with ion-energy of 150 MeV and LET of 41.3 MeV-square cm/mg, the output voltage increased with the increase in fluence. However, for Krypton with ion-energy of 600 MeV and LET of 33.65 MeV-square cm/mg, and two out of four transistors of the converter were permanently damaged. The dc-dc converter with FSF254R4 radiation hardened power MOSFET's did not show significant change at the output voltage with fluence while being irradiated by Krypton with ion energy of 1.20 GeV and LET of 25.97 MeV-square cm/mg. This might be due to fact that the device is radiation hardened.
Quillin, M L; Breyer, W A; Griswold, I J; Matthews, B W
2000-09-29
To investigate the relative importance of size and polarizability in ligand binding within proteins, we have determined the crystal structures of pseudo wild-type and cavity-containing mutant phage T4 lysozymes in the presence of argon, krypton, and xenon. These proteins provide a representative sample of predominantly apolar cavities of varying size and shape. Even though the volumes of these cavities range up to the equivalent of five xenon atoms, the noble gases bind preferentially at highly localized sites that appear to be defined by constrictions in the walls of the cavities, coupled with the relatively large radii of the noble gases. The cavities within pseudo wild-type and L121A lysozymes each bind only a single atom of noble gas, while the cavities within mutants L133A and F153A have two independent binding sites, and the L99A cavity has three interacting sites. The binding of noble gases within two double mutants was studied to characterize the additivity of binding at such sites. In general, when a cavity in a protein is created by a "large-to-small" substitution, the surrounding residues relax somewhat to reduce the volume of the cavity. The binding of xenon and, to a lesser degree, krypton and argon, tend to expand the volume of the cavity and to return it closer to what it would have been had no relaxation occurred. In nearly all cases, the extent of binding of the noble gases follows the trend xenon>krypton>argon. Pressure titrations of the L99A mutant have confirmed that the crystallographic occupancies accurately reflect fractional saturation of the binding sites. The trend in noble gas affinity can be understood in terms of the effects of size and polarizability on the intermolecular potential. The plasticity of the protein matrix permits repulsion due to increased ligand size to be more than compensated for by attraction due to increased ligand polarizability. These results have implications for the mechanism of general anesthesia, the migration of small ligands within proteins, the detection of water molecules within apolar cavities and the determination of crystallographic phases. Copyright 2000 Academic Press.
NASA Astrophysics Data System (ADS)
Robertson, A.; Carroll, K. C.; Kubicki, C.; Purtshert, R.
2017-12-01
The Mesilla Basin/Conejos-Médanos aquifer system, extending from southern New Mexico to Chihuahua, Mexico, is a priority transboundary aquifer under the 2006 United States-Mexico Transboundary Aquifer Assessment Act. Declining water levels, deteriorating water quality, and increasing groundwater use by municipal, industrial, and agricultural users on both sides of the international border raise concerns about long-term aquifer sustainability. Relative contributions of present-day and "paleo" recharge to sustainable fresh groundwater yields has not been determined and evidence suggests that a large source of salinity at the distal end of the Mesilla Basin is saline discharge from deep groundwater flow. The magnitude and distribution of those deep saline flow paths are not determined. The contribution of deep groundwater to discharge and salinity in the shallow groundwater and surface water of the Mesilla Basin will be determined by collecting discrete groundwater samples and analyzing for aqueous geochemical and isotopic tracers, as well as the radioisotopes of argon and krypton. Analytes include major ions, trace elements, the stable isotopes of water, strontium and boron isotopes, uranium isotopes, the carbon isotopes of dissolved inorganic carbon, noble gas concentrations and helium isotope ratios. Dissolved gases are extracted and captured from groundwater wells using membrane contactors in a process known as ultra-trace sampling. Gas samples are analyzed for radioisotope ratios of krypton by the ATTA method and argon by low-level counting. Effectiveness of the ultra-trace sampling device and method was evaluated by comparing results of tritium concentrations to the krypton-85 content. Good agreement between the analyses, especially in samples with undetectable tritium, indicates that the ultra-trace procedure is effective and confirms that introduction of atmospheric air has not occurred. The geochemistry data indicate a complex system of geochemical endmembers, and mixing between these endmembers. Ongoing work seeks to better constrain groundwater ages and mixing models through the coupled use of conventional aqueous geochemical and isotopic analysis and the ultra-trace constituents.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shand, M.L.; Lai, S.T.
1984-02-01
A CW laser-pumped emerald laser is reported. A 34 percent output power slope efficiency is observed with longitudinal pumping by a krypton laser in a nearly concentric cavity. The laser has been tuned from 728.8 to 809.0 nm. Losses in emerald are larger than those of alexandrite determined in a similar cavity. The present data also indicate that the excited state absorption minimum is shifted from that of alexandrite. 13 references.
Bound-Electron Nonlinearity Beyond the Ionization Threshold.
Wahlstrand, J K; Zahedpour, S; Bahl, A; Kolesik, M; Milchberg, H M
2018-05-04
We present absolute space- and time-resolved measurements of the ultrafast laser-driven nonlinear polarizability in argon, krypton, xenon, nitrogen, and oxygen up to ionization fractions of a few percent. These measurements enable determination of the strongly nonperturbative bound-electron nonlinear polarizability well beyond the ionization threshold, where it is found to remain approximately quadratic in the laser field, a result normally expected at much lower intensities where perturbation theory applies.
Elimination of ``memory`` from sample handling and inlet system of a mass spectrometer
Chastgner, P.
1991-05-08
This paper describes a method for preparing the sample handling and inlet system of a mass spectrometer for analysis of a subsequent sample following analysis of a previous sample comprising the flushing of the system interior with supercritical CO{sub 2} and venting the interior. The method eliminates the effect of system ``memory`` on the subsequent analysis, especially following persistent samples such as xenon and krypton.
Atomic emission lines in the near ultraviolet; hydrogen through krypton, section 1
NASA Technical Reports Server (NTRS)
Kelly, R. L.
1979-01-01
A compilation of spectra from the first 36 elements was prepared from published literature available through October 1977. In most cases, only those lines which were actually observed in emission or absorption are listed. The wavelengths included range from 2000 Angstroms to 3200 Angstroms with some additional lines up to 3500 Angstroms. Only lines of stripped atoms are reported; no molecular bands are included.
A Preliminary Study of Krypton Laser-Induced Fluorescence
2010-07-01
Induced Fluorescence 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) William A. Hargus, Jr. (AFRL/RZSS) 5d. PROJECT NUMBER R 5e. TASK...replacement for xenon. This study examines the potential applications of laser-induced fluorescence as a plasma diagnostic technique for Kr I and Kr...II. Candidate electronic transitions are examined to determine their suitability for successful routine application of laser-induced fluorescence
Channel-specific dielectronic recombination of Ge(XXXII), Se(XXXIV), and Kr(XXXVI)
NASA Astrophysics Data System (ADS)
El Machtoub, G.
2004-04-01
We present explicit calculations of channel-specific dielectronic recombination cross sections for hydrogen-like germanium, Ge(XXXII); selenium, Se(XXXIV); and krypton, Kr(XXXVI). The convoluted cross sections characterize K-shell emission spectra over a wide energy range where contributions from high-n (n = 2-10), satellite lines are included. The high-n contributions presented are important for better diagnostics in the domain of high-temperature plasmas.
Atomic emission lines in the near ultraviolet; hydrogen through krypton, section 2
NASA Technical Reports Server (NTRS)
Kelly, R. L.
1979-01-01
A compilation of spectra from the first 36 elements was prepared from published literature available through October 1977. In most cases, only those lines which were actually observed in emission or absorption are listed. The wavelengths included range from 2000 Angstroms to 3200 Angstroms with some additional lines up to 3500 Angstroms. Only lines of stripped atoms are reported; no molecular bands are included.
Bound-Electron Nonlinearity Beyond the Ionization Threshold
NASA Astrophysics Data System (ADS)
Wahlstrand, J. K.; Zahedpour, S.; Bahl, A.; Kolesik, M.; Milchberg, H. M.
2018-05-01
We present absolute space- and time-resolved measurements of the ultrafast laser-driven nonlinear polarizability in argon, krypton, xenon, nitrogen, and oxygen up to ionization fractions of a few percent. These measurements enable determination of the strongly nonperturbative bound-electron nonlinear polarizability well beyond the ionization threshold, where it is found to remain approximately quadratic in the laser field, a result normally expected at much lower intensities where perturbation theory applies.
Background Pressure Effects on Krypton Hall Effect Thruster Internal Acceleration
2013-08-01
This was also previously seen for xenon. Several interpretations of the continued velocity dis- tribution broadening of the high pressure case of...acceleration region into the thruster rel- ative to lower background pressures. We have at- tributed this behavior to increased electron mobility...density. While the data presented thus far does shown some changes in the breadth of the velocity Kr II dis- tributions with increasing
Krypton-85 Powered Lights for Airfield Application.
1981-11-01
Department of Energy.(DOE), and eight lights were fabricated for testing by actual observation under airfield conditions. Light is produced in the units...concepts of radionuclide-powered lights, the R&D program carried out, and fabrication constraints involved in the production of the experimental...visible light has been known for many years. Early use of radium mixed with zinc sulfide phosphors provided self-illuminated clock dials. The military has
Effects of pulmonary inhalation on hyperpolarized krypton-83 magnetic resonance T1 relaxation
NASA Astrophysics Data System (ADS)
Stupic, K. F.; Elkins, N. D.; Pavlovskaya, G. E.; Repine, J. E.; Meersmann, T.
2011-07-01
The 83Kr magnetic resonance (MR) relaxation time T1 of krypton gas in contact with model surfaces was previously found to be highly sensitive to surface composition, surface-to-volume ratio, and surface temperature. The work presented here explored aspects of pulmonary 83Kr T1 relaxation measurements in excised lungs from healthy rats using hyperpolarized (hp) 83Kr with approximately 4.4% spin polarization. MR spectroscopy without spatial resolution was applied to the ex vivo lungs that actively inhale hp 83Kr through a custom designed ventilation system. Various inhalation schemes were devised to study the influence of anatomical dead space upon the measured 83Kr T1 relaxation times. The longitudinal 83Kr relaxation times in the distal airways and the respiratory zones were independent of the lung inhalation volume, with T1 = 1.3 s and T1 = 1.0 s, depending only on the applied inhalation scheme. The obtained data were highly reproducible between different specimens. Further, the 83Kr T1 relaxation times in excised lungs were unaffected by the presence of up to 40% oxygen in the hp gas mixture. The results support the possible importance of 83Kr as a biomarker for evaluating lung function.
Inertial Fusion Target Physics Advantages with the Krypton Fluoride Laser
NASA Astrophysics Data System (ADS)
Obenschain, Stephen
2010-11-01
The krypton fluoride (KrF) laser's short wavelength, broad bandwidth and capability to provide extremely uniform target illumination are advantages towards obtaining high gain direct drive implosions. The short wavelength helps suppress deleterious laser-plasma instabilities, and allows one to employ higher ablation pressures. In addition, the KrF architecture allows one to zoom down the focal diameter to follow the size of the imploding pellet, thereby improving the coupling efficiency. The NRL researchers have been conducting theoretical and experimental studies to quantify the beneficial effects of utilizing KrF light. Experiments using the Nike facility have confirmed that KrF light significantly increases the threshold for laser-plasma instability. This presentation will discuss the observed target physics with KrF light and its effects towards facilitating the high gains needed for power production with inertial fusion. Simulations indicate that shock ignited designs can achieve gains above 200 with KrF energies as low a 1 megajoule. For fusion energy a laser driver must be capable of high repetition rates (5-10 Hz) along with adequate efficiency and durability. The Electra KrF 30-cm aperture electron-beam-pumped amplifier has demonstrated long duration continuous operation at high-repetition rates. This and other advances show that the KrF laser should be able to meet the requirements.
First Detection of Krypton and Xenon in a White Dwarf
NASA Technical Reports Server (NTRS)
Werner, Klaus; Rauch, Thomas; Ringat, Ellen; Kruk, Jeffrey W.
2012-01-01
We report on the first detection of the noble gases krypton (Z = 36) and xenon (54) in a white dwarf. About 20 KrVI-VII and Xe VI-VII lines were discovered in the ultraviolet spectrum of the hot DO-type white dwarf RE 0503-289. The observations, performed with the Far Ultraviolet Spectroscopic Explorer, also reveal highly ionized photospheric lines from other trans-iron group elements, namely Ga (31), Ge (32), As (33), Se (34), Mo (42), Sn (50), Te (52), and I (53), from which gallium and molybdenum are new discoveries in white dwarfs, too. For Kr and Xe, we performed an NLTE analysis and derived mass fractions of log Kr = -4.3 plus or minus 0.5 and log Xe = -4.2 plus or minus 0.6, corresponding to an enrichment by factors of 450 and 3800, respectively, relative to the Sun. The origin of the large overabundances is unclear. We discuss the roles of neutron-capture nucleosynthesis in the-precursor star and radiation-driven diffusion. It is possible that diffusion is insignificant and thaI the observed metal abundances constrain the evolutionary history of the star. Its hydrogen deficiency may be the consequence of a late helium-shell nash or a binary white dwarf merger.
Development of Atmospheric Air 85Kr Monitoring Methodology on the Territory of the USSR
NASA Astrophysics Data System (ADS)
Pakhomov, Sergei; Dubasov, Yury
2014-05-01
Highly sensitive, low-background and high-performance method of beta-radioactivity measurements of the gas samples was developed in mid-eighties at Khlopin Radium institute. This method was based on the use of the serial automated installation for liquid scintillation measurements and special scintillating cells. Cells were equipped with the gas valve, and their internal surface were covered by a thin layer of organic scintillator. This method found was successfully was applied for 85Kr activity measurements in atmospheric krypton samples and for 85Kr concentration measurements in atmospheric air. For the first time, method developed for 85Kr activity measurements, was practically tested in May - June, 1986, while studying radioactive pollution characteristics in the air basin of Russia and Ukraine after the Chernobyl NPP accident. Thus for sampling of atmospheric krypton the industrial krypton-xenon mix manufactured at air-separating plants, located in the cities of Cherepovets, Lipetsk, Krivoi Rog and Enakiyevo was used. In the end of April and in the first half of May it was determined that 1,5-fold excess concentrations of 85Kr in atmospheric air were observed in atmospheric air of considerable part of the European territory of Russia and Ukraine During the period from 1987 to 1991 this method was used for monitoring of 85Kr on the territory of the former USSR in the air basin of Russia, Ukraine and Kazakhstan. Industrial krypton-xenon mix manufactured at 14 large air-separating plants was also used for sampling. Six of them were situated in Russia (Novomoskovsk, Lipetsk, Cherepovets, Chelyabinsk, Nizhni Tagil, Orsk). Seven - in Ukraine (Enakiyevo, Kommunarsk, Krivoi Rog, Makeyevka, Mariupol, Severodonetsk, Dneprodzerzhinsk). One plant was situated in Temirtau, in Kazakhstan. The analysis indicated that in Krivoi Rog; Dneprozhzerzhinsk; Severodonetsk; Makeyevka; Mariupol; Enakiyevo; Kommunarsk; Novomoskovsk and Cherepovets the average 85Kr concentration in atmospheric air was close to background level during monitoring. But in Lipetsk; Orsk; Nizhni Tagil and Temirtau 10-20% excess of background level was systematically observed. In Chelyabinsk concentration of 85Kr steadily exceeded this level by 2-3 times, and incidentally exceeded it for order. Generally, during this period about 1500 values of concentration 85Kr were obtained. Actually, the large-scale monitoring system of atmospheric 85Kr with a binding of sampling points to 14 air-separating plants covered the territory 1000 x 3000 km was created. The developed method of 85Kr activity measurement was successfully applied also when carrying out expedition works in Northern Atlantic during the period from 1987 to 1994 with use o ZIF-1000 cryogenic installation for sampling, which initially was intended for liquid nitrogen manufacturing at the ship. Generally, 80 measurements of 85Kr concentration were obtained using this method. It was determined, that the average concentration of 85Kr in atmospheric air in the open regions of the Atlantic Ocean, were close to background level during monitoring. The concentrations of 85Kr steadily exceeded this level by 2-3 times in English Channel, and incidentally exceeded it in tens times.
Pressure cryocooling protein crystals
Kim, Chae Un [Ithaca, NY; Gruner, Sol M [Ithaca, NY
2011-10-04
Preparation of cryocooled protein crystal is provided by use of helium pressurizing and cryocooling to obtain cryocooled protein crystal allowing collection of high resolution data and by heavier noble gas (krypton or xenon) binding followed by helium pressurizing and cryocooling to obtain cryocooled protein crystal for collection of high resolution data and SAD phasing simultaneously. The helium pressurizing is carried out on crystal coated to prevent dehydration or on crystal grown in aqueous solution in a capillary.
Ion Thruster Development at NASA Lewis Research Center
NASA Technical Reports Server (NTRS)
Sovey, James S.; Hamley, John A.; Patterson, Michael J.; Rawlin, Vincent K.; Sarver-Verhey, Timothy R.
1992-01-01
Recent ion propulsion technology efforts at NASA's Lewis Research Center including development of kW-class xenon ion thrusters, high power xenon and krypton ion thrusters, and power processors are reviewed. Thruster physical characteristics, performance data, life projections, and power processor component technology are summarized. The ion propulsion technology program is structured to address a broad set of mission applications from satellite stationkeeping and repositioning to primary propulsion using solar or nuclear power systems.
S3 targets monitoring with an electron gun
NASA Astrophysics Data System (ADS)
Kallunkathariyil, J.; Stodel, Ch.; Marry, C.; Frémont, G.; Bastin, B.; Piot, J.; Clément, E.; Le Moal, S.; Morel, V.; Thomas, J.-C.; Kamalou, O.; Spitaëls, C.; Savajols, H.; Vostinar, M.; Pellemoine, F.; Mittig, W.
2018-05-01
The monitoring of targets under irradiation was investigated using a 20 keV electron beam. An integrated and automated electron beam deflection was developed allowing a monitoring over the whole surface of target materials. Thus, local defects could be identified on-line during an experiment performed at GANIL involving different materials irradiated with a focused krypton beam at 10.5 MeV/u. Performances of this target monitoring system are presented in this paper.
Demonstration of Laser-Induced Fluorescence on Krypton Hall Effect Thruster
2011-08-10
5b. GRANT NUMBER Thruster 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) William A. Hargus Jr., Gregory X. Azarnia, and Michael R. Nakles 5d. PROJECT... William A. Hargus, Jr. a. REPORT Unclassified b. ABSTRACT Unclassified c. THIS PAGE Unclassified SAR 13 19b. TELEPHONE NUMBER (include...Thruster William A. Hargus, Jr.∗ Gregory M. Azarnia† Michael R. Nakles‡ Air Force Research Laboratory, Edwards Air Force Base, CA 93524 There is growing
Superduck Marine Meteorological Experiment Data Summary: Mean Values and Turbulence Parameters.
1988-08-01
number) This report summarizes the Mean values and turbulence parameters Of Meteorological measurements made during an experiment at Duck, NC, during...Sept-Oct 1986. The measure- ments wore made to Calculate wind stress in the nearshore area. Wind stress is a primary forcing function for nearshore waves...measure. Only in recent years has technology made it possible to accurately measure its fluctuations. The krypton hygrometer is a recent development
Kr II Laser-Induced Fluorescence for Measuring Plasma Acceleration (Preprint)
2012-02-01
Unclassified b. ABSTRACT Unclassified c. THIS PAGE Unclassified SAR 13 19b. TELEPHONE NUMBER (include area code) N /A Standard Form 298 (Rev. 8...thruster operation was measured with a cold cathode ionization gauge to be 1×10−3 Pa, corrected for krypton (N2 conversion to Kr pressure multiplicative...the breathing mode oscillation is correlated to the width of the veloc- ity distributions. Therefore, reducing discharge channel plasma turbulence will
DOE Office of Scientific and Technical Information (OSTI.GOV)
Collin, Blaise P.; Petti, David A.; Demkowicz, Paul A.
Safety tests were conducted on fuel compacts from AGR-1, the first irradiation experiment of the Advanced Gas Reactor (AGR) Fuel Development and Qualification program, at temperatures ranging from 1600 to 1800 °C to determine fission product release at temperatures that bound reactor accident conditions. The PARFUME (PARticle FUel ModEl) code was used to predict the release of fission products silver, cesium, strontium, and krypton from fuel compacts containing tristructural isotropic (TRISO) coated particles during 15 of these safety tests. Comparisons between PARFUME predictions and post-irradiation examination results of the safety tests were conducted on two types of AGR-1 compacts: compactsmore » containing only intact particles and compacts containing one or more particles whose SiC layers failed during safety testing. In both cases, PARFUME globally over-predicted the experimental release fractions by several orders of magnitude: more than three (intact) and two (failed SiC) orders of magnitude for silver, more than three and up to two orders of magnitude for strontium, and up to two and more than one orders of magnitude for krypton. The release of cesium from intact particles was also largely over-predicted (by up to five orders of magnitude) but its release from particles with failed SiC was only over-predicted by a factor of about 3. These over-predictions can be largely attributed to an over-estimation of the diffusivities used in the modeling of fission product transport in TRISO-coated particles. The integral release nature of the data makes it difficult to estimate the individual over-estimations in the kernel or each coating layer. Nevertheless, a tentative assessment of correction factors to these diffusivities was performed to enable a better match between the modeling predictions and the safety testing results. The method could only be successfully applied to silver and cesium. In the case of strontium, correction factors could not be assessed because potential release during the safety tests could not be distinguished from matrix content released during irradiation. Furthermore, in the case of krypton, all the coating layers are partly retentive and the available data did not allow the level of retention in individual layers to be determined, hence preventing derivation of any correction factors.« less
NASA Astrophysics Data System (ADS)
Farhat, Ahmad H.
This dissertation, which is in the area of atomic physics, concentrates on the study of the interaction between VUV-soft X-ray radiation and atoms in the gas phase. The main area of interest is the study of Auger decay in atoms utilizing the process known as the resonance Auger effect, where an inner shell electron is excited to an unfilled orbital followed by the ejection of an Auger electron. The measurements in this thesis were performed by using the high resolution Atomic, Molecular and Optical Physics undulator beam line, which utilizes a spherical grating monochromator at the Advanced Light Source at Lawrence Berkeley National Laboratory. The research focused on three rare gases, argon, krypton and xenon. For argon, high resolution angular-resolved measurements of the 2p → 4s, 3d, 4d resonant Auger lines have been achieved. By measuring photoelectron spectra simultaneously at two different angles using efficient time of flight spectrometers, the angular distributions anisotropy parameters β have been measured, and relative intensities have been evaluated for each of the resolved final ionic states. For krypton, the resonant Auger decay of all the photoexcited Kr 3d3/2,5/2-1 nl (n = 5-9) states have been studied using an angle resolved two dimensional photoelectron spectroscopic technique, in which the electron yield was measured as a function of both photon energy and electron kinetic energy. Angular distributions, spectator and shake probabilities have been derived for the Kr 3d-1np/to4s- 14p-1mp + e/sp- (n = 5-9, m = 5-11) resonance Auger decay. The results show that the spectator-core coupling is strong at lower n (n = 5,6) but it lessens for higher n, with a shake up of m = n + 1 preferred. Finally for xenon, the autoionization resonances and angular distribution of the 4d → 6p decay spectrum were studied utilizing the Auger resonant Raman effect. Using this technique, β parameters of almost all 5p4/ (3P,/ 1D,/ 1S) 6p final ionic states were determined. These results contribute to our understanding of atomic structure and dynamics of inner shell processes and hopefully will stimulate further experimental and theoretical work.
Collin, Blaise P.; Petti, David A.; Demkowicz, Paul A.; ...
2016-04-07
Safety tests were conducted on fuel compacts from AGR-1, the first irradiation experiment of the Advanced Gas Reactor (AGR) Fuel Development and Qualification program, at temperatures ranging from 1600 to 1800 °C to determine fission product release at temperatures that bound reactor accident conditions. The PARFUME (PARticle FUel ModEl) code was used to predict the release of fission products silver, cesium, strontium, and krypton from fuel compacts containing tristructural isotropic (TRISO) coated particles during 15 of these safety tests. Comparisons between PARFUME predictions and post-irradiation examination results of the safety tests were conducted on two types of AGR-1 compacts: compactsmore » containing only intact particles and compacts containing one or more particles whose SiC layers failed during safety testing. In both cases, PARFUME globally over-predicted the experimental release fractions by several orders of magnitude: more than three (intact) and two (failed SiC) orders of magnitude for silver, more than three and up to two orders of magnitude for strontium, and up to two and more than one orders of magnitude for krypton. The release of cesium from intact particles was also largely over-predicted (by up to five orders of magnitude) but its release from particles with failed SiC was only over-predicted by a factor of about 3. These over-predictions can be largely attributed to an over-estimation of the diffusivities used in the modeling of fission product transport in TRISO-coated particles. The integral release nature of the data makes it difficult to estimate the individual over-estimations in the kernel or each coating layer. Nevertheless, a tentative assessment of correction factors to these diffusivities was performed to enable a better match between the modeling predictions and the safety testing results. The method could only be successfully applied to silver and cesium. In the case of strontium, correction factors could not be assessed because potential release during the safety tests could not be distinguished from matrix content released during irradiation. Furthermore, in the case of krypton, all the coating layers are partly retentive and the available data did not allow the level of retention in individual layers to be determined, hence preventing derivation of any correction factors.« less
1992-02-01
a definitely related Government procurement operation, the fact ti ’it the Govern- ment may have formulated, furnished, or in any way supplied the...rapid rcxprired in which krypton is bonded to an clement other than acquisition of the free induction decays with a high-field pulse fluorine...spectroscopy is the single most powerful technique used in the structural characterization of noble gas species. This technique is especially useful in
An experimental study of the isotopic enrichment in Ar, Kr, and Xe when trapped in water ice
NASA Technical Reports Server (NTRS)
Notesco, G.; Laufer, D.; Bar-Nun, A.; Owen, T.
1999-01-01
The isotopic enrichment of argon, krypton, and xenon, when trapped in water ice, was studied experimentally. The isotopes were found to be enriched according to their (m1/m2)1/2 ratio. These enrichment factors could be useful for comparison among the uncertain cosmic or solar isotopic ratios, the hopeful in situ cometary ratio, and those in Earth's atmosphere, in the context of cometary delivery of volatiles to Earth.
X-ray Fluorescence Measurements of Turbulent Methane-Oxygen Shear Coaxial Flames (Briefing Charts)
2015-03-01
Radiography- Radial EPL Profiles • Near-injector EPL profiles have elliptical shape expected from a solid liquid jet • Closest measurements were...turbulent flames relevant to liquid rocket engines – Explore the use of two different tracers, Argon & Krypton – Identify a path forward to apply these...made 0.02 mm downstream • EPL decreases axially as liquid core is atomized and droplets are accelerated – EPL is a function of local mass flux
Stability of a Shock-Decelerated Ablation Front
2009-01-01
the target through the ablation front. Our experiments on the Nike laser at the Naval Research Laboratory (NRL) are aimed at obtaining...separated from the CH foil by a 100-120 μm wide vacuum gap. The front side of the plastic foil is irradiated by 37 overlapping beams of the Nike ...krypton fluoride laser ( 248=Lλ nm) [19]. The Nike laser produces a very uniform irradiation with a time-averaged rms non-uniformity ɘ.3% in a central
Kang, Jun-Won; Kim, Sang-Soon; Kang, Dong-Hyun
2018-07-01
The object of this study was to elucidate the bactericidal mechanism of a 222 nm Krypton Chlorine (KrCl) excilamp compared with that of a 254 nm Low Pressure mercury (LP Hg) lamp. The KrCl excilamp had higher bactericidal capacity against Gram-positive pathogenic bacteria (Staphylococcus aureus and L. monocytogenes) and Gram-negative pathogenic bacteria (S. Typhimurium and E. coli O157:H7) than did the LP Hg lamp when cell suspensions in PBS were irradiated with each type of UV lamp. It was found out that the KrCl excilamp induced cell membrane damage as a form of depolarization. From the study of respiratory chain dehydrogenase activity and the lipid peroxidation assay, it was revealed that cell membrane damage was attributed to inactivation of enzymes related to generation of membrane potential and occurrence of lipid peroxidation. Direct absorption of UV radiation which led to photoreaction through formation of an excited state was one of the causes inducing cell damage. Additionally, generation of ROS and thus occurrence of secondary damage can be another cause. The LP Hg lamp only induced damage to DNA but not to other components such as lipids or proteins. This difference was derived from differences of UV radiation absorption by cellular materials. Copyright © 2018 Elsevier Ltd. All rights reserved.
Steady state fractionation of heavy noble gas isotopes in a deep unsaturated zone
Seltzer, Alan M.; Severinghaus, Jeffrey P.; Andraski, Brian J.; Stonestrom, David A.
2017-01-01
To explore steady state fractionation processes in the unsaturated zone (UZ), we measured argon, krypton, and xenon isotope ratios throughout a ∼110 m deep UZ at the United States Geological Survey (USGS) Amargosa Desert Research Site (ADRS) in Nevada, USA. Prior work has suggested that gravitational settling should create a nearly linear increase in heavy-to-light isotope ratios toward the bottom of stagnant air columns in porous media. Our high-precision measurements revealed a binary mixture between (1) expected steady state isotopic compositions and (2) unfractionated atmospheric air. We hypothesize that the presence of an unsealed pipe connecting the surface to the water table allowed for direct inflow of surface air in response to extensive UZ gas sampling prior to our first (2015) measurements. Observed isotopic resettling in deep UZ samples collected a year later, after sealing the pipe, supports this interpretation. Data and modeling each suggest that the strong influence of gravitational settling and weaker influences of thermal diffusion and fluxes of CO2 and water vapor accurately describe steady state isotopic fractionation of argon, krypton, and xenon within the UZ. The data confirm that heavy noble gas isotopes are sensitive indicators of UZ depth. Based on this finding, we outline a potential inverse approach to quantify past water table depths from noble gas isotope measurements in paleogroundwater, after accounting for fractionation during dissolution of UZ air and bubbles.
Krypton tagging velocimetry in a turbulent Mach 2.7 boundary layer
NASA Astrophysics Data System (ADS)
Zahradka, D.; Parziale, N. J.; Smith, M. S.; Marineau, E. C.
2016-05-01
The krypton tagging velocimetry (KTV) technique is applied to the turbulent boundary layer on the wall of the "Mach 3 Calibration Tunnel" at Arnold Engineering Development Complex (AEDC) White Oak. Profiles of velocity were measured with KTV and Pitot-pressure probes in the Mach 2.7 turbulent boundary layer comprised of 99 % {N}2/1 % Kr at momentum-thickness Reynolds numbers of {Re}_{\\varTheta }= 800, 1400, and 2400. Agreement between the KTV- and Pitot-derived velocity profiles is excellent. The KTV and Pitot velocity data follow the law of the wall in the logarithmic region with application of the Van Driest I transformation. The velocity data are analyzed in the outer region of the boundary layer with the law of the wake and a velocity-defect law. KTV-derived streamwise velocity fluctuation measurements are reported and are consistent with data from the literature. To enable near-wall measurement with KTV (y/δ ≈ 0.1-0.2), an 800-nm longpass filter was used to block the 760.2-nm read-laser pulse. With the longpass filter, the 819.0-nm emission from the re-excited Kr can be imaged to track the displacement of the metastable tracer without imaging the reflection and scatter from the read-laser off of solid surfaces. To operate the Mach 3 AEDC Calibration Tunnel at several discrete unit Reynolds numbers, a modification was required and is described herein.
NASA Astrophysics Data System (ADS)
Wenning, Quinn; Madonna, Claudio; Joss, Lisa; Pini, Ronny
2017-04-01
Knowledge of porosity and fracture (aperture) distribution is key towards a sound description of fluid transport in low-permeability rocks. In the context of geothermal energy development, the ability to quantify the transport properties of fractures is needed to in turn quantify the rate of heat transfer, and, accordingly, to optimize the engineering design of the operation. In this context, core-flooding experiments coupled with non-invasive imaging techniques (e.g., X-Ray Computed Tomography - X-Ray CT) represent a powerful tool for making direct observations of these properties under representative geologic conditions. This study focuses on quantifying porosity and fracture aperture distribution in a fractured westerly granite core by using two recently developed experimental protocols. The latter include the use of a highly attenuating gas [Vega et al., 2014] and the application of the so-called missing CT attenuation method [Huo et al., 2016] to produce multidimensional maps of the pore space and of the fractures. Prior to the imaging experiments, the westerly granite core (diameter: 5 cm, length: 10 cm) was thermally shocked to induce micro-fractured pore space; this was followed by the application of the so-called Brazilian method to induce a macroscopic fracture along the length of the core. The sample was then mounted in a high-pressure aluminum core-holder, exposed to a confining pressure and placed inside a medical CT scanner for imaging. An initial compressive pressure cycle was performed to remove weak asperities and reduce the hysteretic behavior of the fracture with respect to effective pressure. The CT scans were acquired at room temperature and 0.5, 5, 7, and 10 MPa effective pressure under loading and unloading conditions. During scanning the pore fluid pressure was undrained and constant, and the confining pressure was regulated at the desired pressure with a high precision pump. Highly transmissible krypton and helium gases were used as saturating fluids to obtain a sufficiently high contrast in the acquired CT images (˜ 474 HU). 3D reconstructions of the sample have been prepared in terms of porosity at a maximum resolution of (0.24×0.24×1) mm3 . Porosity is estimated via the X-ray saturation technique, where porosity is a function of the difference between CT numbers of pure helium and krypton and the difference between the CT numbers of an individual voxel saturated with helium and krypton, respectively. Applying this method with krypton and helium is advantageous for low permeable samples where achieving complete water saturation is difficult. This allows for quantification of voxel-by-voxel-porosity distribution where the whole core porosity is less than 2%. The fracture aperture is assessed using the measured missing CT attenuation method. Use of the medical CT scanner to estimate intrinsic rock properties requires careful voxel-by-voxel consideration and appraisal of the uncertainty, which can be reduced by subtracting multiple slices taken at the exact same location. These results show that core-scale porosity and fracture distribution heterogeneity play an important role in fluid saturation and heat extraction potential in geothermal systems. Huo, D., Pini, R., and Benson, S.M., 2016, A calibration-free approach for measuring fracture aperture distributions using X-ray computed tomography: Geosphere, v. 12, no. 2, p. 558-571, doi:10.1130/GES01175.1. Vega, B., Dutta, A., and Kovscek, A.R., 2014, CT imaging of low-permeability, dual-porosity systems using high X-ray contrast gas: Transport in Porous Media, v. 101, p. 81-97, doi:10.1007/s11242-013-0232-0.
A Performance and Plume Comparison of Xenon and Krypton Propellant on the SPT-100
2012-07-02
HET (1.35 kW), performance measurements were made using an inverted pendulum thrust stand. The plume was also characterized by a Faraday probe and RPA...performance reduction for the case of the flight model SPT-100 HET (1.35 kW), per- formance measurements were made using an inverted pendulum thrust stand...where high thrust at reduced specific impulse is advantageous, such as orbit raising missions. Bismuth’s main drawback is that the metal must be
NASA Astrophysics Data System (ADS)
Li, Qing; Zhu, Wen-Chao; Zhu, Xi-Ming; Pu, Yi-Kang
2010-09-01
Atmospheric pressure plasma jets, generated in a coaxial dielectric barrier discharge configuration, have been investigated with different flowing gases. Discharge patterns in different tube regions were compared in the flowing gases of helium, neon and krypton. To explain the difference of these discharge patterns, a theoretical analysis is presented to reveal the possible basic processes. A comparison of experimental and theoretical results identifies that Penning ionization is mainly responsible for the discharge patterns of helium and neon plasma jets.
Evaluation results for the positive deep-UV resist AZ DX 46
NASA Astrophysics Data System (ADS)
Spiess, Walter; Lynch, Thomas J.; Le Cornec, Charles; Escher, Gary C.; Kinoshita, Yoshiaki; Kochan, John; Kudo, Takanori; Masuda, Seiya; Mourier, Thierry; Nozaki, Yuko; Olson, Setha G.; Okazaki, Hiroshi; Padmanaban, Munirathna; Pawlowski, Georg; Przybilla, Klaus J.; Roeschert, Horst; Suehiro, Natusmi; Vinet, Francoise; Wengenroth, Horst
1994-05-01
This contribution emphasizes resist application site by communicating lithographic results for AZ DX 46, obtained using the GCA XLS 7800/31 stepper, NA equals 0.53, equipped with krypton fluoride excimer laser ((lambda) equals 248 nm), model 4500 D, as exposure source, delivered by Cymer Laser Technologies. As far as delay time experiments are concerned ASM-L PAS 5500/70 stepper, NA equals 0.42, was used in combination with Lambda Physik excimer laser, model 248 L.
Properties of 83mKr conversion electrons and their use in the KATRIN experiment
NASA Astrophysics Data System (ADS)
Vénos, D.; Sentkerestiová, J.; Dragoun, O.; Slezák, M.; Ryšavý, M.; Špalek, A.
2018-02-01
The gaseous 83mKr will be used as a source of monoenergetic conversion electrons for systematic studies and calibration of the energy scale in the KArlsruhe TRItium Neutrino experiment (KATRIN). Using all existing experimental data the adopted values of the electron binding energies for free krypton were established and the basic conversion electron properties in 83mKr decay were compiled. Modes of the measurements with gaseous 83mKr were suggested for KATRIN.
1992-02-01
COMPOUNDS AND T•EIR OXIDIZING PROPERTIES: VOLUME 3. Prof. G.J. Schrobilgen DTI.DTIC_* Mc Mastf-• University f ELECTE Department of Chemistry JUN 16...STRUCTURAL CHARACTERIZATION OF NEW HIGH- C - F49620-87-C-0049 VALENT INORGANIC FLUORINE COMPOUNDS AND THEIR OXIDIZING PR- 5730 PROPERTIES TA- 007C S6...fluorine, oxidizers of Neon, Krypton. Argon, and Xenon have been synthesized and characterized. KrF+ and ),eF+ caticmns have been made with neutral
NEP technology: FY 1992 milestones (NASA LeRC)
NASA Technical Reports Server (NTRS)
Sovey, Jim
1993-01-01
A discussion of Nuclear Electric Propulsion (NEP) thrusters and facilities is presented in vugraph form. The NEP thrusters are discussed in the context of the following three items: (1) establishing a 100 H test capability for 100-kW magnetoplasmadynamic (MPD) thrusters; (2) demonstrating a lightweight 20-kW krypton ion thruster; and (3) the optimization of the design of low-mass power processor transformers. The primary accomplishment at NEP facilities was the completion of the Electric Propulsion Laboratory's (EPL's) tank 5 cryopump upgrade.
Observation of random lasing in gold-silica nanoshell/water solution
NASA Astrophysics Data System (ADS)
Kang, Jin U.
2006-11-01
The author reports experimental observation of resonant surface plasmon enhanced random lasing in gold-silica nanoshells in de-ionized water. The gold-silica nanoshell/water solution with concentration of 8×109particles/ml was pumped above the surface plasmon resonance frequency using 514nm argon-krypton laser. When pumping power was above the lasing threshold, sharp random lasing peaks occurred near and below the plasmon peak from 720to860nm with a lasing linewidth less than 1nm.
2009-02-26
equation, nitrogen , argon, and krypton are employed while for the D-R equation CO2 is usually used . With the adsorption techniques, certain assumption...structure to characterize it. Lastly, other liquids are used in a density gradient column [73-75] employing a sink-float technique in an attempt to...least 147 incremental intrusion pressures to 275 kPa, using nitrogen gas as the displacing medium. The sample is then loaded into the high-pressure
NASA Technical Reports Server (NTRS)
Manuel, O. K.; Srinivasan, B.; Hennecke, E. W.; Sinclair, D. E.
1972-01-01
The abundance and isotopic composition of helium, neon, argon, krypton, and xenon which were released by stepwise heating of lunar fines (15601.64) and (15271.65) were measured spectrometrically. The results of a composition of noble gases released from the lunar fines with noble gases in meteorites and in the earth are presented along with the isotopic composition of noble gases in lunar fines, in meteorites, and in the atmosphere. A study of two isotopically distinct components of trapped xenon in carbonaceous chondrites is also included.
2007-06-01
the Naval Research Laboratory used to advance the technology towards a KrF laser driver for inertial fusion energy [1-7]. Electra consists of two e...krypton fluoride lasers for fusion energy ," Proc. IEEE, vol. 92, pp. 1043-1056, July 2004. [2] M. C. Myers, J. D. Sethian, J. L. Giuliani, R. Lehmberg...KrF lasers for inertial fusion energy ," Nucl. Fusion, vol. 44, pp. S247-S253, Nov. 2004. [3] J. D. Sethian, M. Friedman, R. H. Lehmberg, M. Myers
Electra: Repetitively Pulsed 700 J, 100 ns Electron Beam Pumped KrF Laser
2006-05-01
the Inertial Fusion Energy (IFE) requirements for durability, efficiency, and cost. The technologies developed on Electra should be directly scalable...and S. Searles, "Electron beam pumped krypton fluoride lasers for fusion energy ," Proc. IEEE, vol. 92, pp. 1043-1056, July 2004. [2] M.C. Myers, J.D...34Repetitively pulsed, high energy KrF lasers for inertial fusion energy ," Nucl. Fusion, vol. 44, pp. S247-S253, November 2004. [3] J.D. Sethian, M
Thermal Loading of Thin Metal Foils Used as Electron Beam Windows for a KRF Laser
2005-06-01
the Inertial Fusion Energy (IFE) requirements for durability, efficiency, and cost. One of the challenging laser components is the pressure foil that...R. Welch, D. V. Rose, and S. Searles, "Electron beam pumped krypton fluoride lasers for fusion energy ," Proc. IEEE, vol. 92, pp. 1043-1056, July...D. Weidenheimer, and D. V. Rose, "Repetitively pulsed, high energy KrF lasers for inertial fusion energy ," Nucl. Fusion, vol. 44, pp. S247-S253
The heavy ions in space experiment
NASA Technical Reports Server (NTRS)
Adams, J. H., Jr.; Beahm, L. P.; Stiller, B.
1985-01-01
The Heavy Ions in Space (HIIS) experiment was developed and is currently in orbit onboard the long duration facility (LDEF). The HIIS will record relativistic cosmic ray nuclei heavier than magnesium and stopping nuclei down to helium. The experiment uses plastic track detectors that have a charge resolution of 0.15 charge units at krypton and 0.10 charge units, or better, for nuclei lighter than cobalt. The HIIS has a collecting power of 2 square meter steradians and it has already collected more than a year's data.
46 CFR 151.50-34 - Vinyl chloride (vinyl chloride monomer).
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Vinyl chloride (vinyl chloride monomer). 151.50-34... chloride (vinyl chloride monomer). (a) Copper, aluminum, magnesium, mercury, silver, and their alloys shall... equipment that may come in contact with vinyl chloride liquid or vapor. (b) Valves, flanges, and pipe...
Kr II laser-induced fluorescence for measuring plasma acceleration.
Hargus, W A; Azarnia, G M; Nakles, M R
2012-10-01
We present the application of laser-induced fluorescence of singly ionized krypton as a diagnostic technique for quantifying the electrostatic acceleration within the discharge of a laboratory cross-field plasma accelerator also known as a Hall effect thruster, which has heritage as spacecraft propulsion. The 728.98 nm Kr II transition from the metastable 5d(4)D(7/2) to the 5p(4)P(5/2)(∘) state was used for the measurement of laser-induced fluorescence within the plasma discharge. From these measurements, it is possible to measure velocity as krypton ions are accelerated from near rest to approximately 21 km/s (190 eV). Ion temperature and the ion velocity distributions may also be extracted from the fluorescence data since available hyperfine splitting data allow for the Kr II 5d(4)D(7/2)-5p(4)P(5/2)(∘) transition lineshape to be modeled. From the analysis, the fluorescence lineshape appears to be a reasonable estimate for the relatively broad ion velocity distributions. However, due to an apparent overlap of the ion creation and acceleration regions within the discharge, the distributed velocity distributions increase ion temperature determination uncertainty significantly. Using the most probable ion velocity as a representative, or characteristic, measure of the ion acceleration, overall propellant energy deposition, and effective electric fields may be calculated. With this diagnostic technique, it is possible to nonintrusively characterize the ion acceleration both within the discharge and in the plume.
NASA Astrophysics Data System (ADS)
White, R. D.; Cocks, D.; Boyle, G.; Casey, M.; Garland, N.; Konovalov, D.; Philippa, B.; Stokes, P.; de Urquijo, J.; González-Magaña, O.; McEachran, R. P.; Buckman, S. J.; Brunger, M. J.; Garcia, G.; Dujko, S.; Petrovic, Z. Lj
2018-05-01
Accurate modelling of electron transport in plasmas, plasma-liquid and plasma-tissue interactions requires (i) the existence of accurate and complete sets of cross-sections, and (ii) an accurate treatment of electron transport in these gaseous and soft-condensed phases. In this study we present progress towards the provision of self-consistent electron-biomolecule cross-section sets representative of tissue, including water and THF, by comparison of calculated transport coefficients with those measured using a pulsed-Townsend swarm experiment. Water–argon mixtures are used to assess the self-consistency of the electron-water vapour cross-section set proposed in de Urquijo et al (2014 J. Chem. Phys. 141 014308). Modelling of electron transport in liquids and soft-condensed matter is considered through appropriate generalisations of Boltzmann’s equation to account for spatial-temporal correlations and screening of the electron potential. The ab initio formalism is applied to electron transport in atomic liquids and compared with available experimental swarm data for these noble liquids. Issues on the applicability of the ab initio formalism for krypton are discussed and addressed through consideration of the background energy of the electron in liquid krypton. The presence of self-trapping (into bubble/cluster states/solvation) in some liquids requires a reformulation of the governing Boltzmann equation to account for the combined localised–delocalised nature of the resulting electron transport. A generalised Boltzmann equation is presented which is highlighted to produce dispersive transport observed in some liquid systems.
Constraints on the thermosteric component of Last Interglacial sea level
NASA Astrophysics Data System (ADS)
Shackleton, S. A.; Severinghaus, J. P.; Petrenko, V. V.; Dyonisius, M.; Hmiel, B.
2016-12-01
With global temperatures 1 to 2°C above preindustrial, but sea level exceeding current levels by upwards of 8 meters, the Last Interglacial (LIG) period at 125 ka may provide valuable insight into Earth system constraints under future global warming. The relative contributions of thermal expansion and ice sheet loss to sea level rise over this period are of particular interest in seeking to improve sea level projections in the upcoming decades and beyond. Here we quantify this thermosteric component from a reconstruction of global ocean temperature over the LIG from atmospheric noble gases trapped in glacial ice. With no major sources or sinks outside of the ocean-atmosphere system, the relative changes in the atmospheric content of krypton, xenon, and nitrogen reflect changes in ocean gas storage. This storage is primarily governed by solubility and ocean temperature, making dKr/N2, dXe/N2, and dXe/Kr unique tracers of globally integrated oceanic heat content. However, processes within the firn can fractionate these gases, and firn effects on these tracers must be removed to derive an ocean temperature. We present high precision measurements of these gas ratios along with isotopes of argon, krypton, and xenon in firn air withdrawn from the snowpack at Summit, Greenland. We use these isotopes to identify sources of fractionation within the firn and quantify their effects on the noble gas tracers, enabling a reconstruction of Last Interglacial ocean temperature.
NASA Astrophysics Data System (ADS)
Mousis, Olivier; Guilbert-Lepoutre, A.; Lunine, J. I.; Cochran, A. L.; Waite, J. H.; Petit, J.; Rousselot, P.
2012-10-01
We propose a scenario that explains the apparent nitrogen deficiency in comets in a way consistent with the presence of this molecule in the atmospheres of Pluto and Triton. We use a statistical thermodynamic model to investigate the composition of the successive multiple guest clathrates that may have formed during the cooling of the primordial nebula from the most abundant volatiles present in the gas phase. These clathrates agglomerated with the other ices (pure condensates or stoechiometric hydrates) and formed the building blocks of comets. We report that molecular nitrogen is a poor clathrate former, when we consider a plausible gas phase composition of the primordial nebula. This implies that its trapping into cometesimals requires a low disk temperature (about 20 K) in order to allow the formation of its pure condensate. We find that it is possible to explain the lack of molecular nitrogen in comets as a consequence of their postformation internal heating engendered by the decay of radiogenic nuclides. This scenario is found to be consistent with the presence of nitrogen-rich atmospheres around Pluto and Triton. Our model predicts that comets should present xenon-to-water and krypton-to-water ratios close to solar xenon-to-oxygen and krypton-to-oxygen ratios, respectively. In contrast, the argon-to-water ratio is predicted to be depleted by a factor of about 300 in comets compared to solar argon-to-oxygen, as a consequence of the nitrogen outgassing.
NASA Astrophysics Data System (ADS)
Dvořák, P.; Talába, M.; Obrusník, A.; Kratzer, J.; Dědina, J.
2017-08-01
Two-photon absorption laser-induced fluorescence (TALIF) was utilized for measuring the concentration of atomic hydrogen in a volume dielectric barrier discharge (DBD) ignited in mixtures of Ar, H2 and O2 at atmospheric pressure. The method was calibrated by TALIF of krypton diluted in argon at atmospheric pressure, proving that three-body collisions had a negligible effect on quenching of excited krypton atoms. The diagnostic study was complemented with a 3D numerical model of the gas flow and a zero-dimensional model of the chemistry in order to better understand the reaction kinetics and identify the key pathways leading to the production and destruction of atomic hydrogen. It was determined that the density of atomic hydrogen in Ar-H2 mixtures was in the order of 1021 m-3 and decreased when oxygen was added into the gas mixture. Spatially resolved measurements and simulations revealed a sharply bordered region with low atomic hydrogen concentration when oxygen was added to the gas mixture. At substoichiometric oxygen/hydrogen ratios, this H-poor region is confined to an area close to the gas inlet and it is shown that the size of this region is not only influenced by the chemistry but also by the gas flow patterns. Experimentally, it was observed that a decrease in H2 concentration in the feeding Ar-H2 mixture led to an increase in H production in the DBD.
Method and Apparatus for Preventing Biofouling of Surfaces
2011-06-14
ammonium compounds that are suitable for this purpose include benzalkonium chloride , benzethonium chloride , methylbenzethonium chloride , cetalkonium... chloride , cetylpyridinium chloride , cetrimonium, cetrimide, dofanium chloride , tetraethylammonium bromide, didecyldimethylammonium chloride and domiphen...upon layers of impermeable nano-particles cause diffusing molecules to follow a tortuous, 8 slow path that results in a huge reduction in
Method of processing aluminous ores
Loutfy, Raouf O.; Keller, Rudolf; Yao, Neng-Ping
1981-01-01
A method of producing aluminum chloride from aluminous materials containing compounds of iron, titanium and silicon comprising reacting the aluminous materials with carbon and a chlorine-containing gas at a temperature of about 900.degree. K. to form a gaseous mixture containing chlorides of aluminum, iron, titanium and silicon and oxides of carbon; cooling the gaseous mixture to a temperature of about 400.degree. K. or lower to condense the aluminum chlorides and iron chlorides while titanium chloride and silicon chloride remain in the gas phase to effect a separation thereof; heating the mixture of iron chlorides and aluminum chlorides to a temperature of about 800.degree. K. to form gaseous aluminum chlorides and iron chlorides; passing the heated gases into intimate contact with aluminum sulfide to precipitate solid iron sulfide and to form additional gaseous aluminum chlorides; and separating the gaseous aluminum chloride from the solid iron sulfide.
Development of a Database of Thermochemical Parameters for Use with the SOLGASMIX Computer Program
1988-07-01
TITANIUM CHLORIDE (TICL4) CL4Wl(CR) TUNGSTEN CHLORIDE (WCL4) CL4Wl(G) TUNGSTEN CHLORIDE (WCL4) CL4ZR1(CR) ZIRCONIUM CHLORIDE ( ZRCL4 ) CL4ZR1(G) ZIRCONIUM...CHLORIDE ( ZRCL4 ) % % % CL5MO1(CR) MOLYBDENUM CHLORIDE (MOCL5) CL5MO1(CR,L) MOLYBDENUM CHLORIDE (MOCL5) CL5MO1(G) MOLYBDENUM CHLORIDE (MOCL5) CL5MOI(L
CALCIUM CHLORIDE PLANT LOOKING EAST. CALCIUM CHLORIDE BUILDING IN CENTER, ...
CALCIUM CHLORIDE PLANT LOOKING EAST. CALCIUM CHLORIDE BUILDING IN CENTER, CALCIUM CHLORIDE STORAGE BUILDING ON RIGHT WITH SA (SODA ASH) BUILDING IN RIGHT BACKGROUND. - Solvay Process Company, Calcium Chloride Plant, Between Willis & Milton Avenues, Solvay, Onondaga County, NY
Star, R A; Burg, M B; Knepper, M A
1985-01-01
Cortical collecting ducts (CCD) from rabbits treated with deoxycorticosterone (DOC) actively secrete bicarbonate at high rates. To investigate the mechanism of bicarbonate secretion, we measured bicarbonate and chloride transport in CCD from rabbits treated with DOC for 9-24 d. Removal of chloride (replaced with gluconate) from both perfusate and bath inhibited bicarbonate secretion without changing transepithelial voltage. Removal of chloride only from the bath increased bicarbonate secretion, while removal of chloride only from the perfusate inhibited secretion. In contrast to the effect of removing chloride, removal of sodium from both the perfusate and bath (replacement with N-methyl-D-glucamine) did not change the rate of bicarbonate secretion. The rate of bicarbonate secretion equaled the rate of chloride absorption in tubules bathed with 0.1 mM ouabain to inhibit any cation-dependent chloride transport. Under these conditions, chloride absorption occurred against an electrochemical gradient. Removal of bicarbonate from both the perfusate and bath inhibited chloride absorption. Removal of bicarbonate only from the bath inhibited chloride absorption, while removal of bicarbonate from the lumen stimulated chloride absorption. We conclude that CCD from DOC-treated rabbits actively secrete bicarbonate and actively absorb chloride by an electroneutral mechanism involving 1:1 chloride/bicarbonate exchange. The process is independent of sodium. PMID:3930570
Chloride sensing by WNK1 kinase involves inhibition of autophosphorylation
Piala, Alexander T.; Moon, Thomas M.; Akella, Radha; He, Haixia; Cobb, Melanie H.; Goldsmith, Elizabeth J.
2014-01-01
WNK1 [with no lysine (K)] is a serine-threonine kinase associated with a form of familial hypertension. WNK1 is at the top of a kinase cascade leading to phosphorylation of several cotransporters, in particular those transporting sodium, potassium, and chloride (NKCC), sodium and chloride (NCC), and potassium and chloride (KCC). The responsiveness of NKCC, NCC, and KCC to changes in extracellular chloride parallels their phosphorylation state, provoking the proposal that these transporters are controlled by a chloride-sensitive protein kinase. Here, we found that chloride stabilizes the inactive conformation of WNK1, preventing kinase autophosphorylation and activation. Crystallographic studies of inactive WNK1 in the presence of chloride revealed that chloride binds directly to the catalytic site, providing a basis for the unique position of the catalytic lysine. Mutagenesis of the chloride binding site rendered the kinase less sensitive to inhibition of autophosphorylation by chloride, validating the binding site. Thus, these data suggest that WNK1 functions as a chloride sensor through direct binding of a regulatory chloride ion to the active site, which inhibits autophosphorylation. PMID:24803536
Ogawa, Haruo; Qiu, Yue; Philo, John S; Arakawa, Tsutomu; Ogata, Craig M; Misono, Kunio S
2010-03-01
The binding of atrial natriuretic peptide (ANP) to its receptor requires chloride, and it is chloride concentration dependent. The extracellular domain (ECD) of the ANP receptor (ANPR) contains a chloride near the ANP-binding site, suggesting a possible regulatory role. The bound chloride, however, is completely buried in the polypeptide fold, and its functional role has remained unclear. Here, we have confirmed that chloride is necessary for ANP binding to the recombinant ECD or the full-length ANPR expressed in CHO cells. ECD without chloride (ECD(-)) did not bind ANP. Its binding activity was fully restored by bromide or chloride addition. A new X-ray structure of the bromide-bound ECD is essentially identical to that of the chloride-bound ECD. Furthermore, bromide atoms are localized at the same positions as chloride atoms both in the apo and in the ANP-bound structures, indicating exchangeable and reversible halide binding. Far-UV CD and thermal unfolding data show that ECD(-) largely retains the native structure. Sedimentation equilibrium in the absence of chloride shows that ECD(-) forms a strongly associated dimer, possibly preventing the structural rearrangement of the two monomers that is necessary for ANP binding. The primary and tertiary structures of the chloride-binding site in ANPR are highly conserved among receptor-guanylate cyclases and metabotropic glutamate receptors. The chloride-dependent ANP binding, reversible chloride binding, and the highly conserved chloride-binding site motif suggest a regulatory role for the receptor bound chloride. Chloride-dependent regulation of ANPR may operate in the kidney, modulating ANP-induced natriuresis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ogawa, H.; Qiu, Y; Philo, J
2010-01-01
The binding of atrial natriuretic peptide (ANP) to its receptor requires chloride, and it is chloride concentration dependent. The extracellular domain (ECD) of the ANP receptor (ANPR) contains a chloride near the ANP-binding site, suggesting a possible regulatory role. The bound chloride, however, is completely buried in the polypeptide fold, and its functional role has remained unclear. Here, we have confirmed that chloride is necessary for ANP binding to the recombinant ECD or the full-length ANPR expressed in CHO cells. ECD without chloride (ECD(-)) did not bind ANP. Its binding activity was fully restored by bromide or chloride addition. Amore » new X-ray structure of the bromide-bound ECD is essentially identical to that of the chloride-bound ECD. Furthermore, bromide atoms are localized at the same positions as chloride atoms both in the apo and in the ANP-bound structures, indicating exchangeable and reversible halide binding. Far-UV CD and thermal unfolding data show that ECD(-) largely retains the native structure. Sedimentation equilibrium in the absence of chloride shows that ECD(-) forms a strongly associated dimer, possibly preventing the structural rearrangement of the two monomers that is necessary for ANP binding. The primary and tertiary structures of the chloride-binding site in ANPR are highly conserved among receptor-guanylate cyclases and metabotropic glutamate receptors. The chloride-dependent ANP binding, reversible chloride binding, and the highly conserved chloride-binding site motif suggest a regulatory role for the receptor bound chloride. Chloride-dependent regulation of ANPR may operate in the kidney, modulating ANP-induced natriuresis.« less
Ogawa, Haruo; Qiu, Yue; Philo, John S; Arakawa, Tsutomu; Ogata, Craig M; Misono, Kunio S
2010-01-01
The binding of atrial natriuretic peptide (ANP) to its receptor requires chloride, and it is chloride concentration dependent. The extracellular domain (ECD) of the ANP receptor (ANPR) contains a chloride near the ANP-binding site, suggesting a possible regulatory role. The bound chloride, however, is completely buried in the polypeptide fold, and its functional role has remained unclear. Here, we have confirmed that chloride is necessary for ANP binding to the recombinant ECD or the full-length ANPR expressed in CHO cells. ECD without chloride (ECD(−)) did not bind ANP. Its binding activity was fully restored by bromide or chloride addition. A new X-ray structure of the bromide-bound ECD is essentially identical to that of the chloride-bound ECD. Furthermore, bromide atoms are localized at the same positions as chloride atoms both in the apo and in the ANP-bound structures, indicating exchangeable and reversible halide binding. Far-UV CD and thermal unfolding data show that ECD(−) largely retains the native structure. Sedimentation equilibrium in the absence of chloride shows that ECD(−) forms a strongly associated dimer, possibly preventing the structural rearrangement of the two monomers that is necessary for ANP binding. The primary and tertiary structures of the chloride-binding site in ANPR are highly conserved among receptor-guanylate cyclases and metabotropic glutamate receptors. The chloride-dependent ANP binding, reversible chloride binding, and the highly conserved chloride-binding site motif suggest a regulatory role for the receptor bound chloride. Chloride-dependent regulation of ANPR may operate in the kidney, modulating ANP-induced natriuresis. PMID:20066666
CALCIUM CHLORIDE PLANT LOOKING EAST. CALCIUM CHLORIDE BUILDING ON LEFT, ...
CALCIUM CHLORIDE PLANT LOOKING EAST. CALCIUM CHLORIDE BUILDING ON LEFT, CALCIUM CHLORIDE STORAGE BUILDING ON RIGHT OF CENTER WITH TOP OF SA (SODA ASH) BUILDING IN RIGHT BACKGROUND. - Solvay Process Company, Calcium Chloride Plant, Between Willis & Milton Avenues, Solvay, Onondaga County, NY
Effects of Cations on Corrosion of Inconel 625 in Molten Chloride Salts
NASA Astrophysics Data System (ADS)
Zhu, Ming; Ma, Hongfang; Wang, Mingjing; Wang, Zhihua; Sharif, Adel
2016-04-01
Hot corrosion of Inconel 625 in sodium chloride, potassium chloride, magnesium chloride, calcium chloride and their mixtures with different compositions is conducted at 900°C to investigate the effects of cations in chloride salts on corrosion behavior of the alloy. XRD, SEM/EDS were used to analyze the compositions, phases, and morphologies of the corrosion products. The results showed that Inconel 625 suffers more severe corrosion in alkaline earth metal chloride molten salts than alkaline metal chloride molten salts. For corrosion in mixture salts, the corrosion rate increased with increasing alkaline earth metal chloride salt content in the mixture. Cations in the chloride molten salts mainly affect the thermal and chemical properties of the salts such as vapor pressure and hydroscopicities, which can affect the basicity of the molten salt. Corrosion of Inconel 625 in alkaline earth metal chloride salts is accelerated with increasing basicity.
Strong higher-order resonant contributions to x-ray line polarization in hot plasmas
NASA Astrophysics Data System (ADS)
Shah, Chintan; Amaro, Pedro; Steinbrügge, Rene; Beilmann, Christian; Bernitt, Sven; Fritzsche, Stephan; Surzhykov, Andrey; Crespo López-Urrutia, José R.; Tashenov, Stanislav
2016-06-01
We studied angular distributions of x rays emitted in resonant recombination of highly charged iron and krypton ions, resolving dielectronic, trielectronic, and quadruelectronic channels. A tunable electron beam drove these processes, inducing x rays registered by two detectors mounted along and perpendicular to the beam axis. The measured emission asymmetries comprehensively benchmarked full-order atomic calculations. We conclude that accurate polarization diagnostics of hot plasmas can only be obtained under the premise of inclusion of higher-order processes that were neglected in earlier work.
1986-09-30
4 . ~**..ft.. ft . - - - ft SI TABLES 9 I. SA32~40 Single Event Upset Test, 1140-MeV Krypton, 9/l8/8~4. . .. .. .. .. .. .16 II. CRUP Simulation...cosmic ray interaction analysis described in the remainder of this report were calculated using the CRUP computer code 3 modified for funneling. The... CRUP code requires, as inputs, the size of a depletion region specified as a retangular parallel piped with dimensions a 9 b S c, the effective funnel
Acceleration to High Velocities and Heating by Impact Using Nike KrF Laser
2010-01-01
Acceleration to high velocities and heating by impact using Nike KrF laser. Max Karasik,1, ∗ J. L. Weaver,1 Y. Aglitskiy,2 T. Watari,3 Y. Arikawa,3 T...Suita, Osaka 565-0871, Japan 4RSI, Lanham, MD 20706 The Nike krypton fluoride laser [S. P. Obenschain, S. E. Bodner, D. Colombant, K. Gerber, R. H...COVERED 00-00-2010 to 00-00-2010 4. TITLE AND SUBTITLE Acceleration to high velocities and heating by impact using Nike KrF laser. 5a. CONTRACT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tingey, J.M.; Fulton, J.L.; Smith, R.D.
1990-03-08
The van der Waals attractive interactions between aqueous droplets in water-in-oil type microemulsions have been investigated for a range of continuous-phase solvents including the alkanes from methane to isooctane and the noble gases, krypton and xenon. Hamaker constants for water droplets with surfactant shells of the sodium bis(2-ethylhexyl) sulfosuccinate (AOT) in subcritical and supercritical solvents were calculated by using Lifshitz theory and the resulting interaction potential calculations qualitatively account for many features of the phase behavior of these systems.
40 CFR Table 2 to Subpart Ggg of... - Partially Soluble HAP
Code of Federal Regulations, 2012 CFR
2012-07-01
... Trichloroethylene Chloroethane (ethyl chloride) Trimethylpentane Vinyl acetate Xylene (p) Vinyl chloride N-hexane... Methylene chloride Allyl chloride N,N-dimethylaniline Benzene Propionaldehyde Benzyl chloride Propylene...
40 CFR Table 2 to Subpart Ggg of... - Partially Soluble HAP
Code of Federal Regulations, 2011 CFR
2011-07-01
... Trichloroethylene Chloroethane (ethyl chloride) Trimethylpentane Vinyl acetate Xylene (p) Vinyl chloride N-hexane... Methylene chloride Allyl chloride N,N-dimethylaniline Benzene Propionaldehyde Benzyl chloride Propylene...
40 CFR Table 2 to Subpart Ggg of... - Partially Soluble HAP
Code of Federal Regulations, 2010 CFR
2010-07-01
... Trichloroethylene Chloroethane (ethyl chloride) Trimethylpentane Vinyl acetate Xylene (p) Vinyl chloride N-hexane... Methylene chloride Allyl chloride N,N-dimethylaniline Benzene Propionaldehyde Benzyl chloride Propylene...
46 CFR 151.50-34 - Vinyl chloride (vinyl chloride monomer).
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Vinyl chloride (vinyl chloride monomer). 151.50-34 Section 151.50-34 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS... chloride (vinyl chloride monomer). (a) Copper, aluminum, magnesium, mercury, silver, and their alloys shall...
Okamoto, Masaki; Asano, Takuya; Suzuki, Eiichi
2004-08-07
Organotrichlorogermanes were synthesized by the reaction of elemental germanium, tetrachlorogermane and organic chlorides, methyl, propyl, isopropyl and allyl chlorides. Dichlorogermylene formed by the reaction of elemental germanium with tetrachlorogermane was the reaction intermediate, which was inserted into the carbon-chlorine bond of the organic chloride to give organotrichlorogermane. When isopropyl or allyl chloride was used as an organic chloride, organotrichlorogermane was formed also in the absence of tetrachlorogermane. These chlorides were converted to hydrogen chloride, which subsequently reacted with elemental germanium to give the dichlorogermylene intermediate. The reaction of elemental germanium, tetrachlorogermane and organic chlorides provides a simple and easy method for synthesizing organotrichlorogermanes, and all the raw materials are easily available.
40 CFR 415.670 - Applicability; description of the zinc chloride production subcategory.
Code of Federal Regulations, 2010 CFR
2010-07-01
... chloride production subcategory. 415.670 Section 415.670 Protection of Environment ENVIRONMENTAL PROTECTION... CATEGORY Zinc Chloride Production Subcategory § 415.670 Applicability; description of the zinc chloride... chloride. ...
Removal of chloride from MSWI fly ash.
Chen, Wei-Sheng; Chang, Fang-Chih; Shen, Yun-Hwei; Tsai, Min-Shing; Ko, Chun-Han
2012-10-30
The high levels of alkali chloride and soluble metal salts present in MSWI fly ash is worth noting for their impact on the environment. In addition, the recycling or reuse of fly ash has become an issue because of limited landfill space. The chloride content in fly ash limits its application as basis for construction materials. Water-soluble chlorides such as potassium chloride (KCl), sodium chloride (NaCl), and calcium chloride hydrate (CaCl(2) · 2H(2)O) in fly ash are easily washed away. However, calcium chloride hydroxide (Ca(OH)Cl) might not be easy to leach away at room temperature. The roasting and washing-flushing processes were applied to remove chloride content in this study. Additionally, air and CO(2) were introduced into the washing process to neutralize the hazardous nature of chlorides. In comparison with the water flushing process, the roasting process is more efficient in reducing the process of solid-liquid separation and drying for the reuse of Cl-removed fly ash particles. In several roasting experiments, the removal of chloride content from fly ash at 1050°C for 3h showed the best results (83% chloride removal efficiency). At a solid to liquid ratio of 1:10 the water-flushing process can almost totally remove water-soluble chloride (97% chloride removal efficiency). Analyses of mineralogical change also prove the efficiency of the fly ash roasting and washing mechanisms for chloride removal. Copyright © 2012 Elsevier B.V. All rights reserved.
21 CFR 184.1297 - Ferric chloride.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Ferric chloride. 184.1297 Section 184.1297 Food and... Substances Affirmed as GRAS § 184.1297 Ferric chloride. (a) Ferric chloride (iron (III) chloride, FeC13, CAS Reg. No. 7705-08-0) may be prepared from iron and chlorine or from ferric oxide and hydrogen chloride...
NASA Astrophysics Data System (ADS)
Lilić, S.; Nikolić, D.; Pejkovski, Z.; Velebit, B.; Lakićević, B.; Korićanac, V.; Vranić, D.
2017-09-01
The goal of this study was to examine the possibility of partial replacement of sodium chloride with potassium chloride and ammonium chloride, with the target of achieving less sodium content in meatballs and tomato sauce as well as achieving a better Na:K ratio. The trial consisted of five groups. In the control group of meatballs and sauce, only sodium chloride was added. In group 1, half of the sodium chloride was replaced with potassium chloride related to control group while in group 2 one third of the sodium chloride was replaced with potassium chloride. In group 3, one third of the sodium chloride was replaced with ammonium chloride, and in group 4, sodium chloride was reduced to half the amount in the control group, and 1 g (0.25%) of ammonium chloride was also added. All products were acceptable according to sensory analyses. The largest reductions of sodium content were 44.64%, achieved in meatballs from group 1 and 50.62% in tomato sauce from group 4 in relation to meatballs and tomato sauce from control group. The highest Na:K ratio was calculated in meatballs and tomato sauce from control group, 2.88 and 4.39, respectively. The best Na:K ratio was in meatballs and tomato sauce from group 1, 0.60 and 0.92, respectively, in which half of sodium chloride was replaced with potassium chloride. However, in meatballs and tomato sauce from group 4, with only half the amount of sodium chloride related to control group, the Na:K ratio was worse because in these products, potassium chloride was not added.
Verification of chloride adsorption effect of mortar with salt adsorbent
NASA Astrophysics Data System (ADS)
Hoshina, T.; Nakajima, N.; Sudo, H.; Date, S.
2017-11-01
In order to investigate the chloride adsorption effect of mortar mixed with chloride adsorbent, electrophoresis test using mortar specimen and immersion dry repeated test were conducted to evaluate chloride adsorption effect. As a result, it was confirmed that soluble salt content that causes corrosion of rebar in the specimen was reduced by the chloride adsorbent and corrosion inhibiting effect of the rebar was also obtained. It was also confirmed that by increasing dosage of the chloride adsorbent, the chloride adsorbing effect becomes larger as well..
Yates, Christopher J; Masuyer, Geoffrey; Schwager, Sylva L U; Akif, Mohd; Sturrock, Edward D; Acharya, K Ravi
2014-01-17
Somatic angiotensin-converting enzyme (sACE), a key regulator of blood pressure and electrolyte fluid homeostasis, cleaves the vasoactive angiotensin-I, bradykinin, and a number of other physiologically relevant peptides. sACE consists of two homologous and catalytically active N- and C-domains, which display marked differences in substrate specificities and chloride activation. A series of single substitution mutants were generated and evaluated under varying chloride concentrations using isothermal titration calorimetry. The x-ray crystal structures of the mutants provided details on the chloride-dependent interactions with ACE. Chloride binding in the chloride 1 pocket of C-domain ACE was found to affect positioning of residues from the active site. Analysis of the chloride 2 pocket R522Q and R522K mutations revealed the key interactions with the catalytic site that are stabilized via chloride coordination of Arg(522). Substrate interactions in the S2 subsite were shown to affect chloride affinity in the chloride 2 pocket. The Glu(403)-Lys(118) salt bridge in C-domain ACE was shown to stabilize the hinge-bending region and reduce chloride affinity by constraining the chloride 2 pocket. This work demonstrated that substrate composition to the C-terminal side of the scissile bond as well as interactions of larger substrates in the S2 subsite moderate chloride affinity in the chloride 2 pocket of the ACE C-domain, providing a rationale for the substrate-selective nature of chloride dependence in ACE and how this varies between the N- and C-domains.
Yates, Christopher J.; Masuyer, Geoffrey; Schwager, Sylva L. U.; Akif, Mohd; Sturrock, Edward D.; Acharya, K. Ravi
2014-01-01
Somatic angiotensin-converting enzyme (sACE), a key regulator of blood pressure and electrolyte fluid homeostasis, cleaves the vasoactive angiotensin-I, bradykinin, and a number of other physiologically relevant peptides. sACE consists of two homologous and catalytically active N- and C-domains, which display marked differences in substrate specificities and chloride activation. A series of single substitution mutants were generated and evaluated under varying chloride concentrations using isothermal titration calorimetry. The x-ray crystal structures of the mutants provided details on the chloride-dependent interactions with ACE. Chloride binding in the chloride 1 pocket of C-domain ACE was found to affect positioning of residues from the active site. Analysis of the chloride 2 pocket R522Q and R522K mutations revealed the key interactions with the catalytic site that are stabilized via chloride coordination of Arg522. Substrate interactions in the S2 subsite were shown to affect chloride affinity in the chloride 2 pocket. The Glu403-Lys118 salt bridge in C-domain ACE was shown to stabilize the hinge-bending region and reduce chloride affinity by constraining the chloride 2 pocket. This work demonstrated that substrate composition to the C-terminal side of the scissile bond as well as interactions of larger substrates in the S2 subsite moderate chloride affinity in the chloride 2 pocket of the ACE C-domain, providing a rationale for the substrate-selective nature of chloride dependence in ACE and how this varies between the N- and C-domains. PMID:24297181
PROCESS OF PREPARING ZIRCONIUM OXYCHLORIDE
Wilhelm, H.A.; Andrews, M.L.
1960-06-28
A process is given for preparing zirconyl chloride by mixing solid zirconyl chloride octahydrate and solid zirconium tetrachloride at room temperature whereby both chlorides are converted to zirconyl chloride trinydrate and hydrogen chloride is formed and volatilized by the reaction heat.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akatsuchi, Y.
Mice were x irradiated by whole-body single doses of 700 r (lethal dose). The administration of phenylephrine chloride, naphazoline, tetrahydrozoline chloride, and noradrenaline gave considerable protection against the lethal effect, when an optimal dose of each agent was given. Cocaine chloride, histamine chloride, or adrenaline chloride gave moderate protection. No protective effect was seen after the administration of ephedrine chloride or diphenhydramine. (Abstr. Japan Med., 2, No. 1, Jan. 1962)
NASA Astrophysics Data System (ADS)
Wheeler, Pamela; Cobb, Richard; Hartsfield, Carl; Prince, Benjamin
2016-09-01
Space Situational Awareness (SSA) is of utmost importance in today's congested and contested space environment. Satellites must perform orbital corrections for station keeping, devices like high efficiency electric propulsion systems such as a Hall effect thrusters (HETs) to accomplish this are on the rise. The health of this system is extremely important to ensure the satellite can maintain proper position and perform its intended mission. Electron temperature is a commonly used diagnostic to determine the efficiency of a hall thruster. Recent papers have coordinated near infrared (NIR) spectral measurements of emission lines in xenon and krypton to electron temperature measurements. Ground based observations of these spectral lines could allow the health of the thruster to be determined while the satellite is in operation. Another issue worth considering is the availability of SSA assets for ground-based observations. The current SSA architecture is limited and task saturated. If smaller telescopes, like those at universities, could successfully detect these signatures they could augment data collection for the SSA network. To facilitate this, precise atmospheric modeling must be used to pull out the signature. Within the atmosphere, the NIR has a higher transmission ratio and typical HET propellants are approximately 3x the intensity in the NIR versus the visible spectrum making it ideal for ground based observations. The proposed research will focus on developing a model to determine xenon and krypton signatures through the atmosphere and estimate the efficacy through ground-based observations. The model will take power modes, orbit geometries, and satellite altitudes into consideration and be correlated with lab and field observations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mousis, Olivier; Petit, Jean-Marc; Rousselot, Philippe
We propose a scenario that explains the apparent nitrogen deficiency in comets in a way that is consistent with the fact that the surfaces of Pluto and Triton are dominated by nitrogen-rich ice. We use a statistical thermodynamic model to investigate the composition of the successive multiple guest clathrates that may have formed during the cooling of the primordial nebula from the most abundant volatiles present in the gas phase. These clathrates agglomerated with the other ices (pure condensates or stoichiometric hydrates) and formed the building blocks of comets. We report that molecular nitrogen is a poor clathrate former, whenmore » we consider a plausible gas-phase composition of the primordial nebula. This implies that its trapping into cometesimals requires a low disk temperature ({approx}20 K) in order to allow the formation of its pure condensate. We find that it is possible to explain the lack of molecular nitrogen in comets as a consequence of their postformation internal heating engendered by the decay of short-lived radiogenic nuclides. This scenario is found to be consistent with the presence of nitrogen-rich ice covers on Pluto and Triton. Our model predicts that comets should present xenon-to-water and krypton-to-water ratios close to solar xenon-to-oxygen and krypton-to-oxygen ratios, respectively. In contrast, the argon-to-water ratio is predicted to be depleted by a factor of {approx}300 in comets compared to solar argon-to-oxygen, as a consequence of poor trapping efficiency and radiogenic heating.« less
A non-LTE analysis of high energy density Kr plasmas on Z and NIF
NASA Astrophysics Data System (ADS)
Dasgupta, A.; Clark, R. W.; Ouart, N.; Giuliani, J.; Velikovich, A.; Ampleford, D. J.; Hansen, S. B.; Jennings, C.; Harvey-Thompson, A. J.; Jones, B.; Flanagan, T. M.; Bell, K. S.; Apruzese, J. P.; Fournier, K. B.; Scott, H. A.; May, M. J.; Barrios, M. A.; Colvin, J. D.; Kemp, G. E.
2016-10-01
Multi-keV X-ray radiation sources have a wide range of applications, from biomedical studies and research on thermonuclear fusion to materials science and astrophysics. The refurbished Z pulsed power machine at the Sandia National Laboratories produces intense multi-keV X-rays from argon Z-pinches, but for a krypton Z-pinch, the yield decreases much faster with atomic number ZA than similar sources on the National Ignition Facility (NIF) laser at the Lawrence Livermore National Laboratory. To investigate whether fundamental energy deposition differences between pulsed power and lasers could account for the yield differences, we consider the Kr plasma on the two machines. The analysis assumes the plasma not in local thermodynamic equilibrium, with a detailed coupling between the hydrodynamics, the radiation field, and the ionization physics. While for the plasma parameters of interest the details of krypton's M-shell are not crucial, both the L-shell and the K-shell must be modeled in reasonable detail, including the state-specific dielectronic recombination processes that significantly affect Kr's ionization balance and the resulting X-ray spectrum. We present a detailed description of the atomic model, provide synthetic K- and L-shell spectra, and compare these with the available experimental data from the Z-machine and from NIF to show that the K-shell yield behavior versus ZA is indeed related to the energy input characteristics. This work aims at understanding the probable causes that might explain the differences in the X-ray conversion efficiencies of several radiation sources on Z and NIF.
NASA Astrophysics Data System (ADS)
Matsumoto, Takuya; Chen, Zongyu; Wei, Wen; Yang, Guo-Min; Hu, Shui-Ming; Zhang, Xiangyang
2018-07-01
Groundwater dating by radio-krypton (81Kr; half-life of about 229,000 years) was applied to the sedimentary basin aquifer of the North China Plain (NCP). Krypton gas extracted from deep groundwater in the Coastal Plain was analyzed for 81Kr/Kr ratios by Atom Trap Trace Analysis, which yielded normalized ratios of 0.05 to 0.20, corresponding to groundwater residence times of 0.5-1 million years. Helium isotope compositions were determined on groundwater samples collected from the Central Plain and the Coastal Plain along a flow path of about 200 km. Helium dissolved in the groundwater samples are a mixture of atmospheric, crustal radiogenic and mantle derived sources. Mantle derived 3He contributes up to 30% of the total, and the area of occurrence coincides with zones of previous magmatic/tectonic activities. By contrast, >90% of 4He is derived from crustal reservoirs and correlates with 81Kr ages. The absolute groundwater ages (81Kr) and radiogenic 4He concentrations permit us to calibrate the 4He flux into the aquifer as well as the vertical diffusion rate of 4He to utilize the radiogenic 4He in groundwater as a quantitative age tracer. Previously, groundwater showed 14C activities near the limit of detection (30-40 k yr), in contrast Kr and radiogenic 4He data reveal progressively older ages from the recharge area to the Coastal Plain, from <20,000 yr to 0.5 to 1 Ma along the flow path of the NCP aquifers.
NASA Astrophysics Data System (ADS)
Reader, Joseph; Podpaly, Yuri; Ralchenko, Yuri; Gillaspy, John
2013-05-01
Extreme ultraviolet spectra of highly charged krypton atoms were produced with an electron beam ion trap (EBIT) and recorded with a flat-field grazing-incidence spectrometer. The wavelength range was 3-18 nm. Wavelength calibration was provided by known lines of highly ionized Kr as well as spectra of C, O, Xe, and Ba. The observed spectra were interpreted with the aid of collisional-radiative modeling of the EBIT plasma. For the Al-like ion Kr23+ the allowed resonance lines 3s23p 2P-3s23d 2D exhibited extreme deviation from the normal ratios for lines of this multiplet. In particular, the 2P3/2-2D5/2 transition, normally the strongest, was observed to be the weakest. This effect was explained by the fact that in the low electron density environment of EBIT the 2D5/2 level is primarily populated by electron excitation from 2P3/2. However, the presence of a magnetic dipole M1 transition 3s23p 2P1/2-2P3/2 reduces the population of 2P3/2 and hence the population of 2D5/2. We are conducting further modeling with varying electron density to try to reproduce the observed line ratios. This could serve as a diagnostic tool for determining electron density in EBIT and fusion energy devices. Supported by Office of Fusion Energy Sciences of Dept. of Energy.
Energy transport in plasmas produced by a high brightness krypton fluoride laser focused to a line
DOE Office of Scientific and Technical Information (OSTI.GOV)
Al-Hadithi, Y.; Tallents, G.J.; Zhang, J.
A high brightness krypton fluoride Raman laser (wavelength 0.268 [mu]m) generating 0.3 TW, 12 ps pulses with 20 [mu]rad beam divergence and a prepulse of less than 10[sup [minus]10] has been focused to produce a 10 [mu]m wide line focus (irradiances [similar to]0.8--4[times]10[sup 15] W cm[sup [minus]2]) on plastic targets with a diagnostic sodium fluoride (NaF) layer buried within the target. Axial and lateral transport of energy has been measured by analysis of x-ray images of the line focus and from x-ray spectra emitted by the layer of NaF with varying overlay thicknesses. It is shown that the ratio ofmore » the distance between the critical density surface and the ablation surface to the laser focal width controls lateral transport in a similar manner as for previous spot focus experiments. The measured axial energy transport is compared to MEDUSA [J. P. Christiansen, D. E. T. F. Ashby, and K. V. Roberts, Comput. Phys. Commun. [bold 7], 271 (1974)] one-dimensional hydrodynamic code simulations with an average atom post-processor for predicting spectral line intensities. An energy absorption of [similar to]10% in the code gives agreement with the experimental axial penetration. Various measured line ratios of hydrogen- and helium-like Na and F are investigated as temperature diagnostics in the NaF layer using the RATION [R. W. Lee, B. L. Whitten, and R. E. Strout, J. Quant. Spectrosc. Radiat. Transfer [bold 32], 91 (1984)] code.« less
NASA Astrophysics Data System (ADS)
Mousis, Olivier; Guilbert-Lepoutre, Aurélie; Lunine, Jonathan I.; Cochran, Anita L.; Waite, J. Hunter; Petit, Jean-Marc; Rousselot, Philippe
2012-10-01
We propose a scenario that explains the apparent nitrogen deficiency in comets in a way that is consistent with the fact that the surfaces of Pluto and Triton are dominated by nitrogen-rich ice. We use a statistical thermodynamic model to investigate the composition of the successive multiple guest clathrates that may have formed during the cooling of the primordial nebula from the most abundant volatiles present in the gas phase. These clathrates agglomerated with the other ices (pure condensates or stoichiometric hydrates) and formed the building blocks of comets. We report that molecular nitrogen is a poor clathrate former, when we consider a plausible gas-phase composition of the primordial nebula. This implies that its trapping into cometesimals requires a low disk temperature (~20 K) in order to allow the formation of its pure condensate. We find that it is possible to explain the lack of molecular nitrogen in comets as a consequence of their postformation internal heating engendered by the decay of short-lived radiogenic nuclides. This scenario is found to be consistent with the presence of nitrogen-rich ice covers on Pluto and Triton. Our model predicts that comets should present xenon-to-water and krypton-to-water ratios close to solar xenon-to-oxygen and krypton-to-oxygen ratios, respectively. In contrast, the argon-to-water ratio is predicted to be depleted by a factor of ~300 in comets compared to solar argon-to-oxygen, as a consequence of poor trapping efficiency and radiogenic heating.
A pH-independent DNA nanodevice for quantifying chloride transport in organelles of living cells.
Saha, Sonali; Prakash, Ved; Halder, Saheli; Chakraborty, Kasturi; Krishnan, Yamuna
2015-07-01
The concentration of chloride ions in the cytoplasm and subcellular organelles of living cells spans a wide range (5-130 mM), and is tightly regulated by intracellular chloride channels or transporters. Chloride-sensitive protein reporters have been used to study the role of these chloride regulators, but they are limited to a small range of chloride concentrations and are pH-sensitive. Here, we show that a DNA nanodevice can precisely measure the activity and location of subcellular chloride channels and transporters in living cells in a pH-independent manner. The DNA nanodevice, called Clensor, is composed of sensing, normalizing and targeting modules, and is designed to localize within organelles along the endolysosomal pathway. It allows fluorescent, ratiometric sensing of chloride ions across the entire physiological regime. We used Clensor to quantitate the resting chloride concentration in the lumen of acidic organelles in Drosophila melanogaster. We showed that lumenal lysosomal chloride, which is implicated in various lysosomal storage diseases, is regulated by the intracellular chloride transporter DmClC-b.
A pH-independent DNA nanodevice for quantifying chloride transport in organelles of living cells
NASA Astrophysics Data System (ADS)
Saha, Sonali; Prakash, Ved; Halder, Saheli; Chakraborty, Kasturi; Krishnan, Yamuna
2015-07-01
The concentration of chloride ions in the cytoplasm and subcellular organelles of living cells spans a wide range (5-130 mM), and is tightly regulated by intracellular chloride channels or transporters. Chloride-sensitive protein reporters have been used to study the role of these chloride regulators, but they are limited to a small range of chloride concentrations and are pH-sensitive. Here, we show that a DNA nanodevice can precisely measure the activity and location of subcellular chloride channels and transporters in living cells in a pH-independent manner. The DNA nanodevice, called Clensor, is composed of sensing, normalizing and targeting modules, and is designed to localize within organelles along the endolysosomal pathway. It allows fluorescent, ratiometric sensing of chloride ions across the entire physiological regime. We used Clensor to quantitate the resting chloride concentration in the lumen of acidic organelles in Drosophila melanogaster. We showed that lumenal lysosomal chloride, which is implicated in various lysosomal storage diseases, is regulated by the intracellular chloride transporter DmClC-b.
Mapping the spatial distribution of chloride deposition across Australia
NASA Astrophysics Data System (ADS)
Davies, P. J.; Crosbie, R. S.
2018-06-01
The high solubility and conservative behaviour of chloride make it ideal for use as an environmental tracer of water and salt movement through the hydrologic cycle. For such use the spatial distribution of chloride deposition in rainfall at a suitable scale must be known. A number of authors have used point data acquired from field studies of chloride deposition around Australia to construct relationships to characterise chloride deposition as a function of distance from the coast; these relationships have allowed chloride deposition to be interpolated in different regions around Australia. In this paper we took this a step further and developed a chloride deposition map for all of Australia which includes a quantification of uncertainty. A previously developed four parameter model of chloride deposition as a function of distance from the coast for Australia was used as the basis for producing a continental scale chloride deposition map. Each of the four model parameters were made spatially variable by creating parameter surfaces that were interpolated using a pilot point regularisation approach within a parameter estimation software. The observations of chloride deposition were drawn from a literature review that identified 291 point measurements of chloride deposition over a period of 80 years spread unevenly across all Australian States and Territories. A best estimate chloride deposition map was developed from the resulting surfaces on a 0.05 degree grid. The uncertainty in the chloride deposition map was quantified as the 5th and 95th percentile of 1000 calibrated models produced via Null Space Monte Carlo analysis and the spatial variability of chloride deposition across the continent was consistent with landscape morphology. The temporal variability in chloride deposition on a decadal scale was investigated in the Murray-Darling Basin, this highlighted the need for long-term monitoring of chloride deposition if the uncertainty of the continental scale map is to be reduced. Use of the derived chloride deposition map was demonstrated for a probabilistic estimation of groundwater recharge for the southeast of South Australia using the chloride mass balance method.
42 CFR 84.250 - Vinyl chloride respirators; description.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Vinyl chloride respirators; description. 84.250... Respirators § 84.250 Vinyl chloride respirators; description. Vinyl chloride respirators, including all... escape from vinyl chloride atmospheres containing adequate oxygen to support life, are described...
Hydrocracking with molten zinc chloride catalyst containing 2-12% ferrous chloride
Zielke, Clyde W.; Bagshaw, Gary H.
1981-01-01
In a process for hydrocracking heavy aromatic polynuclear carbonaceous feedstocks to produce hydrocarbon fuels boiling below about 475.degree. C. by contacting the feedstocks with hydrogen in the presence of a molten zinc chloride catalyst and thereafter separating at least a major portion of the hydrocarbon fuels from the spent molten zinc chloride catalyst, an improvement comprising: adjusting the FeCl.sub.2 content of the molten zinc chloride to from about 2 to about 12 mol percent based on the mixture of ferrous chloride and molten zinc chloride.
PLUTONIUM RECOVERY FROM NEUTRON-BOMBARDED URANIUM FUEL
Moore, R.H.
1962-04-10
A process of recovering plutonium from neutronbombarded uranium fuel by dissolving the fuel in equimolar aluminum chloride-potassium chloride; heating the mass to above 700 deg C for decomposition of plutonium tetrachloride to the trichloride; extracting the plutonium trichloride into a molten salt containing from 40 to 60 mole % of lithium chloride, from 15 to 40 mole % of sodium chloride, and from 0 to 40 mole % of potassium chloride or calcium chloride; and separating the layer of equimolar chlorides containing the uranium from the layer formed of the plutonium-containing salt is described. (AEC)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Jun; Qiu, Qiwen; Chen, Xiaochi
An experimental study is carried out with the aim to understand the interacted mechanism between carbonation and chloride aerosol attack in ordinary Portland cement (OPC) concrete. Effects of carbonation on the chloride profile, the chloride binding capacity and the chloride diffusion coefficient are evaluated. Besides, effect of chloride aerosol attack on the carbonation rate is investigated. Concrete specimens with three water-to-cement ratios (0.38, 0.47 and 0.53) are fabricated in this work. Tested results demonstrate that carbonation remarkably affects the chloride profile, reduces the chloride binding capacity, and also accelerates the rate of chloride ion diffusion of concrete. Besides, the presencemore » of chloride aerosol can lead to lower the carbonation depth and increase the pH value of carbonated concrete. Microscopic properties such as morphology, porosity, and pore size distribution for the contaminated concretes are explored by scanning electron microscope and mercury intrusion porosimetry, which provide strong evidence to these research findings.« less
Atmospheric chloride: Its implication for foliar uptake and damage
NASA Astrophysics Data System (ADS)
McWilliams, E. L.; Sealy, R. L.
Atmospheric chloride is inversely related to distance from the Texas coast; r2 = 0.86. Levels of atmospheric chloride are higher in the early summer than in the winter because of salt storms. Leaf chloride l'evels of Tillandsia usneoides L. (Spanish moss) reflect the atmospheric chloride levels; r2 = 0.78. The importance of considering the effect of atmospheric chloride on leaf damage to horticultural crops is discussed.
21 CFR 522.1862 - Sterile pralidoxime chloride.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Sterile pralidoxime chloride. 522.1862 Section 522....1862 Sterile pralidoxime chloride. (a) Chemical name. 2-Formyl-1-methylpyridinium chloride oxime. (b) Specifications. Sterile pralidoxime chloride is packaged in vials. Each vial contains 1 gram of sterile...
21 CFR 184.1622 - Potassium chloride.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Potassium chloride. 184.1622 Section 184.1622 Food... Specific Substances Affirmed as GRAS § 184.1622 Potassium chloride. (a) Potassium chloride (KCl, CAS Reg... levels not to exceed current good manufacturing practice. Potassium chloride may be used in infant...
21 CFR 184.1622 - Potassium chloride.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Potassium chloride. 184.1622 Section 184.1622 Food... Specific Substances Affirmed as GRAS § 184.1622 Potassium chloride. (a) Potassium chloride (KCl, CAS Reg... levels not to exceed current good manufacturing practice. Potassium chloride may be used in infant...
40 CFR 61.64 - Emission standard for polyvinyl chloride plants.
Code of Federal Regulations, 2010 CFR
2010-07-01
... chloride plants. 61.64 Section 61.64 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Standard for Vinyl Chloride § 61.64 Emission standard for polyvinyl chloride plants. An owner or operator of a polyvinyl chloride plant shall comply with the requirements of this section and § 61.65. (a...
21 CFR 173.375 - Cetylpyridinium chloride.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Cetylpyridinium chloride. 173.375 Section 173.375... CONSUMPTION Specific Usage Additives § 173.375 Cetylpyridinium chloride. Cetylpyridinium chloride (CAS Reg. No....1666 of this chapter, at a concentration of 1.5 times that of cetylpyridinium chloride. (c) The...
21 CFR 178.3290 - Chromic chloride complexes.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Chromic chloride complexes. 178.3290 Section 178... SANITIZERS Certain Adjuvants and Production Aids § 178.3290 Chromic chloride complexes. Myristo chromic chloride complex and stearato chromic chloride complex may be safely used as release agents in the closure...
Method for the abatement of hydrogen chloride
Winston, S.J.; Thomas, T.R.
1975-11-14
A method is described for reducing the amount of hydrogen chloride contained in a gas stream by reacting the hydrogen chloride with ammonia in the gas phase so as to produce ammonium chloride. The combined gas stream is passed into a condensation and collection vessel, and a cyclonic flow is created in the combined gas stream as it passes through the vessel. The temperature of the gas stream is reduced in the vessel to below the condensation temperature of ammonium chloride in order to crystallize the ammonium chloride on the walls of the vessel. The cyclonic flow creates a turbulence which breaks off the larger particles of ammonium chloride which are, in turn, driven to the bottom of the vessel where the solid ammonium chloride can be removed from the vessel. The gas stream exiting from the condensation and collection vessel is further cleaned and additional ammonium chloride is removed by passing through additional filters.
Method for the abatement of hydrogen chloride
Winston, Steven J.; Thomas, Thomas R.
1977-01-01
The present invention provides a method for reducing the amount of hydrogen chloride contained in a gas stream by reacting the hydrogen chloride with ammonia in the gas phase so as to produce ammonium chloride. The combined gas stream is passed into a condensation and collection vessel and a cyclonic flow is created in the combined gas stream as it passes through the vessel. The temperature of the gas stream is reduced in the vessel to below the condensation temperature of ammonium chloride in order to crystallize the ammonium chloride on the walls of the vessel. The cyclonic flow creates a turbulence which breaks off the larger particles of ammonium chloride which are, in turn, driven to the bottom of the vessel where the solid ammonium chloride can be removed from the vessel. The gas stream exiting from the condensation and collection vessel is further cleaned and additional ammonium chloride is removed by passing through additional filters.
Pore size distribution of OPC and SRPC mortars in presence of chlorides
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suryavanshi, A.K.; Scantlebury, J.D.; Lyon, S.B.
1995-07-01
The pore structure of chloride-free ordinary portland cement (OPC) and sulphate resistant portland cement (SRPC) mortars are compared with the corresponding mortars with NaCl and CaCl{sub 2} added during mixing. In both OPC and SRPC mortars the addition of chlorides reduced the total accessible pore volumes compared to the corresponding chloride-free mortars. Also, in the presence of chlorides, the number of coarse pores were increased. These changes in the pore structure are believed to be due to dense calcium silicate hydrate (C-S-H) gel morphology formed in the presence of chlorides. The SRPC showed greater changes in pore structures than themore » OPC with equivalent amounts of chlorides added. This may be due to the lower chloride binding capacity of the SRPC and hence the higher availability of free chlorides to modify the gel morphology.« less
McGarry, Meghan E; Illek, Beate; Ly, Ngoc P; Zlock, Lorna; Olshansky, Sabrina; Moreno, Courtney; Finkbeiner, Walter E; Nielson, Dennis W
2017-04-01
Ivacaftor, a cystic fibrosis transmembrane conductance regulator (CFTR) potentiator, decreases sweat chloride concentration, and improves pulmonary function in 6% of cystic fibrosis (CF) patients with specific CFTR mutations. Ivacaftor increases chloride transport in many other CFTR mutations in non-human cells, if CFTR is in the epithelium. Some CF patients have CFTR in the epithelium with residual CFTR function. The effect of ivacaftor in these patients is unknown. This was a series of randomized, crossover N-of-1 trials of ivacaftor and placebo in CF patients ≥8 years old with potential residual CFTR function (intermediate sweat chloride concentration, pancreatic sufficient, or mild bronchiectasis on chest CT). Human nasal epithelium (HNE) was obtained via nasal brushing and cultured. Sweat chloride concentration change was the in vivo outcome. Chloride current change in HNE cultures with ivacaftor was the in vitro outcome. Three subjects had decreased sweat chloride concentration (-14.8 to -40.8 mmol/L, P < 0.01). Two subjects had unchanged sweat chloride concentration. Two subjects had increased sweat chloride concentration (+23.8 and +27.3 mmol/L, P < 0.001); both were heterozygous for A455E and pancreatic sufficient. Only subjects with decreased sweat chloride concentration had increased chloride current in HNE cultures. Some CF patients with residual CFTR function have decreased sweat chloride concentration with ivacaftor. Increased chloride current in HNE cultures among subjects with decreased sweat chloride concentrations may predict clinical response to ivacaftor. Ivacaftor can increase sweat chloride concentration in certain mutations with unclear clinical effect. Pediatr Pulmonol. 2017;52:472-479. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Ion-irradiation-induced densification of zirconia sol-gel thin films
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levine, T.E.; Giannelis, E.P.; Kodali, P.
1994-02-01
We have investigated the densification behavior of sol-gel zirconia films resulting from ion irradiation. Three sets of films were implanted with neon, krypton, or xenon. The ion energies were chosen to yield approximately constant energy loss through the film and the doses were chosen to yield similar nuclear energy deposition. Ion irradiation of the sol-gel films resulted in carbon and hydrogen loss as indicated by Rutherford backscattering spectrometry and forward recoil energy spectroscopy. Although the densification was hypothesized to result from target atom displacement, the observed densification exhibits a stronger dependence on electronic energy deposition.
Precision Penning Trap Mass Spectrometry of S, Kr and Xe
NASA Astrophysics Data System (ADS)
Redshaw, Matthew
2005-04-01
Using a phase coherent technique to measure the cyclotron frequency of single ions in a Penning trap [1], we have performed mass measurements on ^32S and the two most abundant krypton and xenon isotopes ^84Kr, ^86Kr, ^ 129Xe and ^132Xe, to relative precisions of 0.1 ppb. This is a factor of ˜10-100 improvement in precision over current values [2]. [1] M.P. Bradley, J.V. Porto, S. Rainville, J.K. Thompson, and D.E. Pritchard, PRL 83, 4510 (1999). [2] G. Audi, A.H. Wapstra, and C. Thibault, Nucl Phys A729, 337 (2003).
NASA Astrophysics Data System (ADS)
Johnson, R. Barry; Herren, Kenneth A.
1990-09-01
The time dependence of the angular reflectance from molecularly contaminated optical surfaces in the Vacuum Ultraviolet (VUV) is measured. The light scattering measurements are accomplished in situ on optical surfaces in real time during deposition of molecular contaminants. The measurements are taken using non-coherent VUV sources with the predominant wavelengths being the Krypton resonance lines at 1236 and 1600 A. Detection of the scattered light is accomplished using a set of three solar blind VUV photomultipliers. An in-plane VUV BRDF (Bidirectional Reflectance Distribution Functions) experiment is described and details of the ongoing program to characterize optical materials exposed to the space environment is reported.
Laser fluorescence bronchoscope for localization of occult lung tumors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Profio, A.E.; Doiron, D.R.; King, E.G.
1979-11-01
A system for imaging occult bronchogenic carcinoma by the fluorescence of previously-injected, tumor-specific compound hematoporphyrin-derivative has been assembled and successfully used to locate a tumor l mm thick. The violet excitation source is a krypton ion laser coupled to fused quartz fiber light conductor. An electrostatic image intensifier attached to a standard flexible fiberoptic bronchoscope provides a bright image even at relatively low irradiance. A red secondary filter rejects most reflected background and autofluorescence. Sensitivity and contrast capability of the system should permit detection of a tumor less than 0.1 mm thick.
Sequential two-photon double ionization of noble gases by circularly polarized XUV radiation
NASA Astrophysics Data System (ADS)
Gryzlova, E. V.; Grum-Grzhimailo, A. N.; Kuzmina, E. I.; Strakhova, S. I.
2014-10-01
Photoelectron angular distributions (PADs) and angular correlations between two emitted electrons in sequential two-photon double ionization (2PDI) of atoms by circularly polarized radiation are studied theoretically. In particular, the sequential 2PDI of the valence n{{p}6} shell in noble gas atoms (neon, argon, krypton) is analyzed, accounting for the first-order corrections to the dipole approximation. Due to different selection rules in ionization transitions, the circular polarization of photons causes some new features of the cross sections, PADs and angular correlation functions in comparison with the case of linearly polarized photons.
Axial momentum lost to a lateral wall of a helicon plasma source.
Takahashi, Kazunori; Chiba, Aiki; Komuro, Atsushi; Ando, Akira
2015-05-15
Momentum exerted to a lateral wall of a helicon plasma source is individually measured for argon, krypton, and xenon gases. A significant loss of the axial plasma momentum to the lateral wall, which has been assumed to be negligible, is experimentally identified when an axially asymmetric density profile is formed in the source. This indicates that the radially lost ions deliver not only the radial momentum but also the axial momentum to the lateral wall. The formation of the axial asymmetry causing the momentum loss is interpreted with competition between the magnetic field and neutral depletion effects.
NASA Technical Reports Server (NTRS)
Wacker, John F.
1989-01-01
The sorption of Ne, Ar, Kr, and Xe was studied in carbon black, acridine carbon, and diamond in an attempt to understand the origin of trapped noble gases in meteorites. The results support a model in which gases are physically adsorbed on interior surfaces formed by a pore labyrinth within amorphous carbons. The data show that: (1) the adsorption/desorption times are controlled by choke points that restrict the movement of noble gas atoms within the pore labyrinth, and (2) the physical adsorption controls the temperature behavior and elemental fractionation patterns.
Alternatives to argon for gas stopping volumes in the B194 neutron imager
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bleuel, D. L.; Anderson, S.; Caggiano, J. A.
2017-05-17
In a recent experiment at Lawrence Berkeley National Laboratory, the 40Ar(d,p)41Ar excitation function between 3-7 MeV was measured, confirming a previous estimation that there may be an intolerable radiation dose from 41Ar production by slowing to rest 6.74 MeV deuterons in the gas cell of the neutron imaging facility being constructed in B194. Gas alternatives to argon are considered, including helium, nitrogen (N2), neon, sulfur hexafluoride (SF6), krypton, and xenon, as well as high atomic number solid backings such as tantalum.
Maximizing energy deposition by shaping few-cycle laser pulses
NASA Astrophysics Data System (ADS)
Gateau, Julien; Patas, Alexander; Matthews, Mary; Hermelin, Sylvain; Lindinger, Albrecht; Kasparian, Jérôme; Wolf, Jean-Pierre
2018-07-01
We experimentally investigate the impact of pulse shape on the dynamics of laser-generated plasma in rare gases. Fast-rising triangular pulses with a slower decay lead to early ionization of the gas and depose energy more efficiently than their temporally reversed counterparts. As a result, in both argon and krypton, the induced shockwave as well as the plasma luminescence are stronger. This is due to an earlier availability of free electrons to undergo inverse Bremsstrahlung on the pulse trailing edge. Our results illustrate the ability of adequately tailored pulse shapes to optimize the energy deposition in gas plasmas.
Modernization of Koesters interferometer and high accuracy calibration gauge blocks
NASA Astrophysics Data System (ADS)
França, R. S.; Silva, I. L. M.; Couceiro, I. B.; Torres, M. A. C.; Bessa, M. S.; Costa, P. A.; Oliveira, W., Jr.; Grieneisen, H. P. H.
2016-07-01
The Optical Metrology Division (Diopt) of Inmetro is responsible for maintaining the national reference of the length unit according to International System of Units (SI) definitions. The length unit is realized by interferometric techniques and is disseminated to the dimensional community through calibrations of gauge blocks. Calibration of large gauge blocks from 100 mm to 1000 mm has been performed by Diopt with a Koesters interferometer with reference to spectral lines of a krypton discharge lamp. Replacement of this lamp by frequency stabilized lasers, traceable now to the time and frequency scale, is described and the first results are reported.
Hollow-Cathode Source Generates Plasma
NASA Technical Reports Server (NTRS)
Deininger, W. D.; Aston, G.; Pless, L. C.
1989-01-01
Device generates argon, krypton, or xenon plasma via thermionic emission and electrical discharge within hollow cathode and ejects plasma into surrounding vacuum. Goes from cold start up to full operation in less than 5 s after initial application of power. Exposed to moist air between operations without significant degradation of starting and running characteristics. Plasma generated by electrical discharge in cathode barrel sustained and aided by thermionic emission from emitter tube. Emitter tube does not depend on rare-earth oxides, making it vulnerable to contamination by exposure to atmosphere. Device modified for use as source of plasma in laboratory experiments or industrial processes.
Regeneration of zinc chloride hydrocracking catalyst
Zielke, Clyde W.
1979-01-01
Improved rate of recovery of zinc values from the solids which are carried over by the effluent vapors from the oxidative vapor phase regeneration of spent zinc chloride catalyst is achieved by treatment of the solids with both hydrogen chloride and calcium chloride to selectively and rapidly recover the zinc values as zinc chloride.
21 CFR 173.255 - Methylene chloride.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Methylene chloride. 173.255 Section 173.255 Food... Related Substances § 173.255 Methylene chloride. Methylene chloride may be present in food under the... label of the hops extract identifies the presence of the methylene chloride and provides for the use of...
21 CFR 184.1138 - Ammonium chloride.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Ammonium chloride. 184.1138 Section 184.1138 Food... Specific Substances Affirmed as GRAS § 184.1138 Ammonium chloride. (a) Ammonium chloride (NH4Cl, CAS Reg. No. 12125-02-9) is produced by the reaction of sodium chloride and an ammonium salt in solution. The...
21 CFR 184.1622 - Potassium chloride.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Potassium chloride. 184.1622 Section 184.1622 Food... GRAS § 184.1622 Potassium chloride. (a) Potassium chloride (KCl, CAS Reg. No. 7447-40-7) is a white... manufacturing practice. Potassium chloride may be used in infant formula in accordance with section 412(g) of...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Emission standard for ethylene... AIR POLLUTANTS National Emission Standard for Vinyl Chloride § 61.65 Emission standard for ethylene dichloride, vinyl chloride and polyvinyl chloride plants. An owner or operator of an ethylene dichloride...
Evaporation behavior of lithium, potassium, uranium and rare earth chlorides in pyroprocessing
NASA Astrophysics Data System (ADS)
Jang, Junhyuk; Kim, Tackjin; Park, Sungbin; Kim, Gha-Young; Kim, Sihyoung; Lee, Sungjai
2017-12-01
The evaporation behaviors of Li, K, U, and rare earth (RE) chlorides were examined for the cathode process in pyroprocessing. The evaporation temperatures of the chlorides were evaluated in vacuum by measuring the weight decrease. In addition, an evaporation test up to 1473 K of the cathode process using a surrogate mixture of uranium and chlorides was conducted. It was found that LiCl evaporated more readily than the other chlorides. The weight of LiCl was rapidly decreased at temperatures above 981 K, while that of KCl was decreased above 1035 K, indicating the evaporation. UCl3 evaporated at temperatures above 1103 K. RE chlorides showed a similar evaporation behavior, evaporating first at 1158 K then rapidly evaporating at temperatures above 1230 K. Thus, the order of evaporation with increasing temperature was found to be LiCl < KCl < UCl3 < RE chlorides, with different RE chlorides evaporating at similar temperature. The surrogate test confirmed the observed evaporation trend of the chlorides during the cathode process, and revealed that the contamination of uranium remains by the back-reaction of RE chlorides is negligible.
NASA Astrophysics Data System (ADS)
Ludwikowski, Jessica J.; Peterson, Eric W.
2018-06-01
In a typical winter season, approximately 471,000 tons of road salt are deposited along roadways in Illinois, USA. An estimated 45% of the deposited road salt will infiltrate through the soils and into shallow aquifers. Transported through shallow aquifers, chloride associated with the road salts has the potential to reside within groundwater for years based on the pathway, the geologic material, and the recharge rate of the aquifer system. Utilizing MODFLOW and MT3D, simulations employing various road-salt application rates were conducted to assess the net accumulation of chloride and the residence times of chloride in an agriculture-dominated watershed that originates in an urban area. A positive-linear relationship was observed between the application rate of chloride and both the maximum chloride concentration and total mass accumulated within the watershed. Simulated annual recharge rates along impacted surfaces ranged from 1,000 to 10,000 mg/L. After 60 years of application, simulated chloride concentrations in groundwater ranged from 197 to 1,900 mg/L. For all application rates, chloride concentrations within the groundwater rose at an annual rate of >3 mg/L. While concentrations increase throughout the system, the majority of chloride accumulation occurs near the roads and the urban areas. Model simulations reveal a positive relationship between application rate and residence time of chloride (1,123-1,288 days based on application rate). The models indicate that continued accumulation of chloride in shallow aquifers can be expected, and methods that apply less chloride effectively need to be examined.
NASA Astrophysics Data System (ADS)
Ludwikowski, Jessica J.; Peterson, Eric W.
2018-01-01
In a typical winter season, approximately 471,000 tons of road salt are deposited along roadways in Illinois, USA. An estimated 45% of the deposited road salt will infiltrate through the soils and into shallow aquifers. Transported through shallow aquifers, chloride associated with the road salts has the potential to reside within groundwater for years based on the pathway, the geologic material, and the recharge rate of the aquifer system. Utilizing MODFLOW and MT3D, simulations employing various road-salt application rates were conducted to assess the net accumulation of chloride and the residence times of chloride in an agriculture-dominated watershed that originates in an urban area. A positive-linear relationship was observed between the application rate of chloride and both the maximum chloride concentration and total mass accumulated within the watershed. Simulated annual recharge rates along impacted surfaces ranged from 1,000 to 10,000 mg/L. After 60 years of application, simulated chloride concentrations in groundwater ranged from 197 to 1,900 mg/L. For all application rates, chloride concentrations within the groundwater rose at an annual rate of >3 mg/L. While concentrations increase throughout the system, the majority of chloride accumulation occurs near the roads and the urban areas. Model simulations reveal a positive relationship between application rate and residence time of chloride (1,123-1,288 days based on application rate). The models indicate that continued accumulation of chloride in shallow aquifers can be expected, and methods that apply less chloride effectively need to be examined.
LIU, LI; CAI, SIYI; QIU, GUIXING; LIN, JIN
2016-01-01
ClC-3 is a volume-sensitive chloride channel that is responsible for cell volume adjustment and regulatory cell volume decrease (RVD). In order to evaluate the effects of fluid shear stress (FSS) stimulation on the osteoblast ClC-3 chloride channel, MC3T3-E1 cells were stimulated by FSS in the experimental group. Fluorescence quantitative polymerase chain reaction was used to detect changes in ClC-3 mRNA expression, the chloride ion fluorescent probe N-(ethoxycarbonylmethyl)-6-methoxyquinolinium bromide (MQAE) was used to detect the chloride channel activity, and whole-cell patch clamping was used to monitor the changes in the volume-sensitive chloride current activated by a hypotonic environment following mechanical stimulation. The results show that the expression of the osteoblast chloride channel ClC-3 was significantly higher in the FSS group compared with the control group. MQAE fluorescence intensity was significantly reduced in the FSS group compared to the control group, suggesting that mechanical stimulation increased chloride channel activity and increased the efflux of intracellular chloride ions. Image analysis of osteoblast volume changes showed that osteoblast RVD was enhanced by mechanical stimulation. Whole-cell patch clamping showed that the osteoblast volume-sensitive chloride current was larger in the stimulated group compared to the control group, suggesting that elevated ClC-3 chloride channel expression results in an increased volume-sensitive chloride current. In conclusion, FSS stimulation enhances the RVD of osteoblast cell by increasing the expression of the ClC-3 and enhancing the chloride channel activity. PMID:27073622
NASA Astrophysics Data System (ADS)
Riyanto; Prawidha, A. D.
2018-01-01
Electrochemical degradation of methylene blue using Carbon-Chitosan-Polyvinyl Chloride (CC-PVC) electrode in sodium chloride have been done. The aim of this work was to degradation of methylene blue using Carbon-Chitosan-Polyvinyl Chloride (CC-PVC). Carbon chitosan composite electrode was preparing by Carbon and Chitosan powder and PVC in 4 mL tetrahydrofuran (THF) solvent and swirled flatly to homogeneous followed by drying in an oven at 100 °C for 3 h. The mixture was placed in stainless steel mould and pressed at 10 ton/cm2. Sodium chloride was used electrolyte solution. The effects of the current and electrolysis time were investigated using spectrophotometer UV-Visible. The experimental results showed that the carbon-chitosan composite electrode have higher effect in the electrochemical degradation of methylene blue in sodium chloride. Based on UV-visible spectra analysis shows current and electrolysis time has high effect to degradation of methylene blue in sodium chloride. Chitosan and polyvinyl chloride can strengthen the bond between the carbons so that the material has the high stability and conductivity. As conclusions is Carbon-Chitosan-Polyvinyl Chloride (CC-PVC) electrode have a high electrochemical activity for degradation of methylene blue in sodium chloride.
Russo, Michael A.; Högenauer, Christoph; Coates, Stephen W.; Santa Ana, Carol A.; Porter, Jack L.; Rosenblatt, Randall L.; Emmett, Michael; Fordtran, John S.
2003-01-01
Due to genetic defects in apical membrane chloride channels, the cystic fibrosis (CF) intestine does not secrete chloride normally. Depressed chloride secretion leaves CF intestinal absorptive processes unopposed, which results in net fluid hyperabsorption, dehydration of intestinal contents, and a propensity to inspissated intestinal obstruction. This theory is based primarily on in vitro studies of jejunal mucosa. To determine if CF patients actually hyperabsorb fluid in vivo, we measured electrolyte and water absorption during steady-state perfusion of the jejunum. As expected, chloride secretion was abnormally low in CF, but surprisingly, there was no net hyperabsorption of sodium or water during perfusion of a balanced electrolyte solution. This suggested that fluid absorption processes are reduced in CF jejunum, and further studies revealed that this was due to a marked depression of passive chloride absorption. Although Na+-glucose cotransport was normal in the CF jejunum, absence of passive chloride absorption completely blocked glucose-stimulated net sodium absorption and reduced glucose-stimulated water absorption 66%. This chloride absorptive abnormality acts in physiological opposition to the classic chloride secretory defect in the CF intestine. By increasing the fluidity of intraluminal contents, absence of passive chloride absorption may reduce the incidence and severity of intestinal disease in patients with CF. PMID:12840066
Electron Detachment Dissociation of Underivatized Chloride-Adducted Oligosaccharides
NASA Astrophysics Data System (ADS)
Kornacki, James R.; Adamson, Julie T.; Håkansson, Kristina
2012-11-01
Chloride anion attachment has previously been shown to aid determination of saccharide anomeric configuration and generation of linkage information in negative ion post-source decay MALDI tandem mass spectrometry. Here, we employ electron detachment dissociation (EDD) and collision activated dissociation (CAD) for the structural characterization of underivatized oligosaccharides bearing a chloride ion adduct. Both neutral and sialylated oligosaccharides are examined, including maltoheptaose, an asialo biantennary glycan (NA2), disialylacto- N-tetraose (DSLNT), and two LS tetrasaccharides (LSTa and LSTb). Gas-phase chloride-adducted species are generated by negative ion mode electrospray ionization. EDD and CAD spectra of chloride-adducted oligosaccharides are compared to the corresponding spectra for doubly deprotonated species not containing a chloride anion to assess the role of chloride adduction in the stimulation of alternative fragmentation pathways and altered charge locations allowing detection of additional product ions. In all cases, EDD of singly chloridated and singly deprotonated species resulted in an increase in observed cross-ring cleavages, which are essential to providing saccharide linkage information. Glycosidic cleavages also increased in EDD of chloride-adducted oligosaccharides to reveal complementary structural information compared to traditional (non-chloride-assisted) EDD and CAD. Results indicate that chloride adduction is of interest in alternative anion activation methods such as EDD for oligosaccharide structural characterization.
40 CFR Table 2 to Subpart Ggg of... - Partially Soluble HAP
Code of Federal Regulations, 2014 CFR
2014-07-01
... Xylene (p) Vinyl chloride N-hexane Xylene (m) Xylene (o) [66 FR 40136, Aug. 2, 2001] ... Acrylonitrile Methylene chloride Allyl chloride N,N-dimethylaniline Benzene Propionaldehyde Benzyl chloride...
40 CFR Table 2 to Subpart Ggg of... - Partially Soluble HAP
Code of Federal Regulations, 2013 CFR
2013-07-01
... Xylene (p) Vinyl chloride N-hexane Xylene (m) Xylene (o) [66 FR 40136, Aug. 2, 2001] ... Acrylonitrile Methylene chloride Allyl chloride N,N-dimethylaniline Benzene Propionaldehyde Benzyl chloride...
[Forensic Analysis for 54 Cases of Suxamethonium Chloride Poisoning].
Zhao, Y F; Zhao, B Q; Ma, K J; Zhang, J; Chen, F Y
2017-08-01
To observe and analyze the performance of forensic science in the cases of suxa- methonium chloride poisoning, and to improve the identification of suxamethonium chloride poisoning. Fifty-four cases of suxamethonium chloride poisoning were collected. The rules of determination of suxamethonium chloride poisoning were observed by the retrospective analysis of pathological and toxicological changes as well as case features. The pathological features of suxamethonium chloride poisoning were similar to the general changes of sudden death, which mainly included acute pulmonary congestion and edema, and partly showed myocardial disarray and fracture. Suxamethonium chloride could be detected in the heart blood of all cases and in skin tissue of part cases. Suxa-methonium chloride poisoning has the characteristics with fast death and covert means, which are difficult to rescue and easily miss inspection. For the cases of sudden death or suspicious death, determination of suxamethonium chloride should be taken as a routine detection index to prevent missing inspection. Copyright© by the Editorial Department of Journal of Forensic Medicine
Fiber optic chloride sensing: if corrosion's the problem, chloride sensing is the key
NASA Astrophysics Data System (ADS)
Fuhr, Peter L.; MacCraith, Brian D.; Huston, Dryver R.; Guerrina, Mario; Nelson, Matthew
1997-09-01
The use of chloride-based deicing agents to help clear US highways of roadway hazards leads to associated chemical related problems. Fouling of local rivers and streams due to runoff of the water borne chlorides is significant and has contributed to local ordances are attempting to force state agencies to reduce, if not eliminate, the use of these chlorides. With respect to the corrosion aspects of chloride application, cracks that occur in the roadway/bridge pavement allow water to seep into the pavement carrying the chloride to the rebar with the resultant increase in corrosion. The costs of this corrosion are considerable and have led to the widespread use of chloride/water impermeable membranes on roadways and especially within bridges. Fiber optic sensor have repeatedly been shown to provide measurement capabilities of parameters within such reinforced concrete structures. Development of a fiber optic chloride sensors capable of being embedded within a roadway or bridge deck is reported.
Guido, Maria; Sarcognato, Samantha; Pelletti, Guido; Fassan, Matteo; Murer, Bruno; Snenghi, Rossella
2016-11-01
Strong experimental and clinical evidences have definitely linked occupational vinyl chloride exposure to development of angiosarcoma of the liver. In contrast, despite the International Agency for Research on Cancer having included vinyl chloride among the causes of hepatocellular carcinoma, the association between vinyl chloride exposure and hepatocellular carcinoma remains debated. This issue is relevant, because occupational exposure to high levels of vinyl chloride may still occur. We report a unique case of sequential occurrences of hepatocellular carcinoma and angiosarcoma of the liver, in a vinyl chloride-exposed worker without cirrhosis and any known risk factor for chronic liver disease. Both the hepatocellular carcinoma and the surrounding normal liver showed micronucleus formation, which reflects genotoxic effect of vinyl chloride. Angiosarcoma showed a KRAS G12D point mutation, which is considered to be characteristic of vinyl chloride-induced angiosarcoma. This case supports the pathogenic role of vinyl chloride in both hepatocellular carcinoma and angiosarcoma development. Copyright © 2016 Elsevier Inc. All rights reserved.
Sweat Chloride as A Biomarker of CFTR Activity: Proof of Concept and Ivacaftor Clinical Trial Data
Accurso, Frank J.; Van Goor, Fredrick; Zha, Jiuhong; Stone, Anne J.; Dong, Qunming; Ordonez, Claudia L.; Rowe, Steven M.; Clancy, John Paul; Konstan, Michael W.; Hoch, Heather E.; Heltshe, Sonya L.; Ramsey, Bonnie W.; Campbell, Preston W.; Ashlock, Melissa A.
2014-01-01
Background We examined data from a Phase 2 trial {NCT00457821 } of ivacaftor, a CFTR potentiator, in cystic fibrosis (CF) patients with a G551D mutation to evaluate standardized approaches to sweat chloride measurement and to explore the use of sweat chloride and nasal potential difference (NPD) to estimate CFTR activity. Methods Sweat chloride and NPD were secondary endpoints in this placebo-controlled, multicenter trial. Standardization of sweat collection, processing, and analysis was employed for the first time.. Sweat chloride and chloride ion transport (NPD) were integrated into a model of CFTR activity. Results Within-patient sweat chloride determinations showed sufficient precision to detect differences between dose-groups and assess ivacaftor treatment effects. Analysis of changes in sweat chloride and NPD demonstrated that patients treated with ivacaftor achieved CFTR activity equivalent to approximately 35%–40% of normal. Conclusions Sweat chloride is useful in multicenter trials as a biomarker of CFTR activity and to test the effect of CFTR potentiators. PMID:24660233
Sweat chloride as a biomarker of CFTR activity: proof of concept and ivacaftor clinical trial data.
Accurso, Frank J; Van Goor, Fredrick; Zha, Jiuhong; Stone, Anne J; Dong, Qunming; Ordonez, Claudia L; Rowe, Steven M; Clancy, John Paul; Konstan, Michael W; Hoch, Heather E; Heltshe, Sonya L; Ramsey, Bonnie W; Campbell, Preston W; Ashlock, Melissa A
2014-03-01
We examined data from a Phase 2 trial {NCT00457821} of ivacaftor, a CFTR potentiator, in cystic fibrosis (CF) patients with aG551D mutation to evaluate standardized approaches to sweat chloride measurement and to explore the use of sweat chloride and nasal potential difference (NPD) to estimate CFTR activity. Sweat chloride and NPD were secondary endpoints in this placebo-controlled, multicenter trial. Standardization of sweat collection, processing,and analysis was employed for the first time. Sweat chloride and chloride ion transport (NPD) were integrated into a model of CFTR activity. Within-patient sweat chloride determinations showed sufficient precision to detect differences between dose-groups and assess ivacaftor treatment effects. Analysis of changes in sweat chloride and NPD demonstrated that patients treated with ivacaftor achieved CFTR activity equivalent to approximately 35%–40% of normal. Sweat chloride is useful in multicenter trials as a biomarker of CFTR activity and to test the effect of CFTR potentiators.
Dynamic [Cl-]i measurement with chloride sensing quantum dots nanosensor in epithelial cells
NASA Astrophysics Data System (ADS)
Wang, Yuchi; Mao, Hua; Wong, Lid B.
2010-02-01
We have synthesized a chloride sensing quantum dots (QD) nanosensor, Cl-QD, for the dynamic measurements of chloride ion concentration in the millimolar range, a sensitivity that is applicable to most physiological intracellular chloride ion concentration ([Cl-]i) measurements in epithelial cells. The Cl-QD is synthesized by conjugating an anion receptor, 1-(2-mercapto-ethyl)-3-phenyl-thiourea (MEPTU) to a water soluble CdSe/ZnS QD at an emission wavelength of 620 nm. Upon binding of chloride ions to the Cl-QD, a photo-induced electron transfer mechanism caused the fluorescence of the QD to quench. This resulted in an inversely proportional relationship between the chloride ion concentration and the fluorescence intensity of the Cl-QD. We have utilized this Cl-QD to measure [Cl-]i in T84 and CF-PAC cultured cells, with either the C1C-2 or CFTR chloride channels being manipulated by pharmacological chloride channel activators and inhibitors. Activations of C1C-2 and CFTR chloride channels in T84 by the respective lubiprostone and genistein caused predictive increases in the fluorescence of the Cl-QD, i.e., a decrease of [Cl-]i. Conversely, glibenclamide, a chloride channel inhibitor, applied to the CF-PAC cells caused a predictable decrease in the fluorescence of Cl-QD due to the increase of [Cl-]i. These are the first data in using QD-based chloride ion sensors for dynamic measurements of intracellular chloride ion concentrations in epithelial cells.
Production of anhydrous aluminum chloride composition
Vandergrift, G.F. III; Krumpelt, M.; Horwitz, E.P.
1981-10-08
A process is described for producing an anhydrous aluminum chloride composition from a water-based aluminous material such as a slurry of aluminum hydroxide in a multistage extraction process in which the aluminum ion is first extracted into an organic liquid containing an acidic extractant and then extracted from the organic phase into an alkali metal chloride or chlorides to form a melt containing a mixture of chlorides of alkali metal and aluminum. In the process, the organic liquid may be recycled. In addition, the process advantageously includes an electrolysis cell for producing metallic aluminum and the alkali metal chloride or chlorides may be recycled for extraction of the aluminum from the organic phase.
Production of anhydrous aluminum chloride composition and process for electrolysis thereof
Vandegrift, George F.; Krumpelt, Michael; Horwitz, E. Philip
1983-01-01
A process for producing an anhydrous aluminum chloride composition from a water-based aluminous material such as a slurry of aluminum hydroxide in a multistage extraction process in which the aluminum ion is first extracted into an organic liquid containing an acidic extractant and then extracted from the organic phase into an alkali metal chloride or chlorides to form a melt containing a mixture of chlorides of alkali metal and aluminum. In the process, the organic liquid may be recycled. In addition, the process advantageously includes an electrolysis cell for producing metallic aluminum and the alkali metal chloride or chlorides may be recycled for extraction of the aluminum from the organic phase.
Surface aspects of pitting and stress corrosion cracking
NASA Technical Reports Server (NTRS)
Truhan, J. S., Jr.; Hehemann, R. F.
1977-01-01
The pitting and stress corrosion cracking of a stable austenitic stainless steel in aqueous chloride environments were investigated using a secondary ion mass spectrometer as the primary experimental technique. The surface concentration of hydrogen, oxygen, the hydroxide, and chloride ion, magnesium or sodium, chromium and nickel were measured as a function of potential in both aqueous sodium chloride and magnesium chloride environments at room temperature and boiling temperatures. It was found that, under anodic conditions, a sharp increase in the chloride concentration was observed to occur for all environmental conditions. The increase may be associated with the formation of an iron chloride complex. Higher localized chloride concentrations at pits and cracks were also detected with an electron microprobe.
21 CFR 184.1845 - Stannous chloride (anhydrous and dihydrated).
Code of Federal Regulations, 2010 CFR
2010-04-01
.... Anhydrous stannous chloride (SnCl2, CAS Reg. No. 7772-99-8) is the chloride salt of metallic tin. It is prepared by reacting molten tin with either chlorine or gaseous tin tetrachloride. Dihydrated stannous chloride (SnCl2·2H2O, CAS Reg. No. 10025-0969-091) is the chloride salt of metallic tin that contains two...
21 CFR 184.1845 - Stannous chloride (anhydrous and dihydrated).
Code of Federal Regulations, 2013 CFR
2013-04-01
.... Anhydrous stannous chloride (SnCl2, CAS Reg. No. 7772-99-8) is the chloride salt of metallic tin. It is prepared by reacting molten tin with either chlorine or gaseous tin tetrachloride. Dihydrated stannous chloride (SnCl2·2H2O, CAS Reg. No. 10025-69-1) is the chloride salt of metallic tin that contains two...
21 CFR 184.1845 - Stannous chloride (anhydrous and dihydrated).
Code of Federal Regulations, 2011 CFR
2011-04-01
.... Anhydrous stannous chloride (SnCl2, CAS Reg. No. 7772-99-8) is the chloride salt of metallic tin. It is prepared by reacting molten tin with either chlorine or gaseous tin tetrachloride. Dihydrated stannous chloride (SnCl2·2H2O, CAS Reg. No. 10025-0969-091) is the chloride salt of metallic tin that contains two...
21 CFR 184.1845 - Stannous chloride (anhydrous and dihydrated).
Code of Federal Regulations, 2012 CFR
2012-04-01
.... Anhydrous stannous chloride (SnCl2, CAS Reg. No. 7772-99-8) is the chloride salt of metallic tin. It is prepared by reacting molten tin with either chlorine or gaseous tin tetrachloride. Dihydrated stannous chloride (SnCl2·2H2O, CAS Reg. No. 10025-69-1) is the chloride salt of metallic tin that contains two...
21 CFR 184.1193 - Calcium chloride.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Calcium chloride. 184.1193 Section 184.1193 Food... Specific Substances Affirmed as GRAS § 184.1193 Calcium chloride. (a) Calcium chloride (CaCl2·2H2O, CAS Reg. No. 10035-04-8) or anhydrous calcium chloride (CaCl2, CAS Reg. No. 10043-52-4) may be commercially...
21 CFR 184.1193 - Calcium chloride.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Calcium chloride. 184.1193 Section 184.1193 Food... Specific Substances Affirmed as GRAS § 184.1193 Calcium chloride. (a) Calcium chloride (CaCl2·2H2O, CAS Reg. No. 10035-04-8) or anhydrous calcium chloride (CaCl2, CAS Reg. No. 10043-52-4) may be commercially...
21 CFR 184.1193 - Calcium chloride.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Calcium chloride. 184.1193 Section 184.1193 Food... GRAS § 184.1193 Calcium chloride. (a) Calcium chloride (CaCl2·2H2O, CAS Reg. No. 10035-04-8) or anhydrous calcium chloride (CaCl2, CAS Reg. No. 10043-52-4) may be commercially obtained as a byproduct in...
Saleh, Livia; Plieth, Christoph
2013-01-01
The involvement of chloride in salt stress symptoms and salt tolerance mechanisms in plants has been less investigated in the past. Therefore, we studied the salt-induced chloride influx in Arabidopsis expressing the GFP-based anion indicator Clomeleon. High salt concentrations induce two phases of chloride influx. The fast kinetic phase is likely caused by membrane depolarization, and is assumed to be mediated by channels. This is followed by a slower "saturation" phase, where chloride is accumulated in the cytoplasm. Both phases of chloride uptake are dependent on the presence of external calcium. In general: with high [Ca2+] less chloride is accumulated in the cytoplasm. Surprisingly, also the internal calcium availability has an impact on chloride transport. A complete block of the second phase of chloride influx is achieved by the anion channel blocker A9C and trivalent cations (La3+, Gd3+, and Al3+). Other channel blockers and diuretics were found to inhibit the process partially. The results suggest that several transporter species are involved here, including electroneutral cation-chloride-cotransporters, and a part of chloride possibly enters the cells through cation channels after salt application. PMID:23603974
Inhibitory effect of DIDS, NPPB, and phloretin on intracellular chloride channels.
Malekova, Lubica; Tomaskova, Jana; Novakova, Marie; Stefanik, Peter; Kopacek, Juraj; Lakatos, Boris; Pastorekova, Silvia; Krizanova, Olga; Breier, Albert; Ondrias, Karol
2007-11-01
We studied the effects of the chloride channel blockers, 5-nitro-2-(phenylpropylamino)-benzoate (NPPB), dihydro-4,4' diisothiocyanostilbene-2,2'-disulphonic acid (DIDS), and phloretin on H2O2-induced primary culture cardiomyocyte apoptosis and activity of intracellular chloride channels obtained from rat heart mitochondrial and lysosomal vesicles. The chloride channel blockers (100 micromol/l) inhibited the H2O2-induced cardiomyocytes apoptosis. We characterized the effect of the blockers on single channel properties of the chloride channels derived from the mitochondrial and lysosomal vesicles incorporated into a bilayer lipid membrane. The single chloride channel currents were measured in 250:50 mmol/l KCl cis/trans solutions. NPPB, DIDS, and phloretin inhibited the chloride channels by decreasing the channel open probability in a concentration-dependent manner with EC50 values of 42, 7, and 20 micromol/l, respectively. NPPB and phloretin inhibited the channel's conductance and open dwell time, indicating that they could affect the chloride selective filter, pore permeability, and gating mechanism of the chloride channels. DIDS and NPPB inhibited the channels from the other side than bongkrekic acid and carboxyatractyloside. The results may contribute to understand a possible involvement of intracellular chloride channels in apoptosis and cardioprotection.
Chloride channels as tools for developing selective insecticides.
Bloomquist, Jeffrey R
2003-12-01
Ligand-gated chloride channels underlie inhibition in excitable membranes and are proven target sites for insecticides. The gamma-aminobutyric acid (GABA(1)) receptor/chloride ionophore complex is the primary site of action for a number of currently used insecticides, such as lindane, endosulfan, and fipronil. These compounds act as antagonists by stabilizing nonconducting conformations of the chloride channel. Blockage of the GABA-gated chloride channel reduces neuronal inhibition, which leads to hyperexcitation of the central nervous system, convulsions, and death. We recently investigated the mode of action of the silphinenes, plant-derived natural compounds that structurally resemble picrotoxinin. These materials antagonize the action of GABA on insect neurons and block GABA-mediated chloride uptake into mouse brain synaptoneurosomes in a noncompetitive manner. In mammals, avermectins have a blocking action on the GABA-gated chloride channel consistent with a coarse tremor, whereas at longer times and higher concentrations, activation of the channel suppresses neuronal activity. Invertebrates display ataxia, paralysis, and death as the predominant signs of poisoning, with a glutamate-gated chloride channel playing a major role. Additional target sites for the avermectins or other chloride channel-directed compounds might include receptors gated by histamine, serotonin, or acetylcholine.The voltage-sensitive chloride channels form another large gene family of chloride channels. Voltage-dependent chloride channels are involved in a number of physiological processes including: maintenance of electrical excitability, chloride ion secretion and resorption, intravesicular acidification, and cell volume regulation. A subset of these channels is affected by convulsants and insecticides in mammals, although the role they play in acute lethality in insects is unclear. Given the wide range of functions that they mediate, these channels are also potential targets for insecticide development. Copyright 2003 Wiley-Liss, Inc.
Bukiet, Frédéric; Couderc, Guillaume; Camps, Jean; Tassery, Hervé; Cuisinier, Frederic; About, Imad; Charrier, Anne; Candoni, Nadine
2012-11-01
The purposes of the present study were to (1) assess the effect of the addition of benzalkonium chloride to sodium hypochlorite on its wetting properties, contact angle, and surface energy; (2) determine the critical micellar concentration of benzalkonium chloride in sodium hypochlorite; and (3) investigate the influence of addition of benzalkonium chloride on the free chlorine level, cytotoxicity, and antiseptic properties of the mixture. Solutions of benzalkonium chloride, with concentrations ranging from 0%-1%, were mixed in 2.4% sodium hypochlorite and tested as follows. The wetting properties were investigated by measuring the contact angle of the solutions on a nondehydrated dentin surface by using the static sessile drop method. The pending drop technique was subsequently used to determine the surface energy of the solutions. The critical micellar concentration of benzalkonium chloride mixed in sodium hypochlorite was calculated from the data. When 2.4% NaOCl was mixed with benzalkonium chloride at the critical micellar concentration, 3 parameters were tested: free chloride content, cytotoxicity, and antibacterial effects against Enterococcus faecalis. The contact angle (P < .001) as well as the surface energy (P < .001) significantly decreased with increasing benzalkonium chloride concentrations. The critical micellar concentration of benzalkonium chloride in sodium hypochlorite was 0.008%. At this concentration, the addition of benzalkonium chloride had no effect on the free chlorine content, cytotoxicity, or antibacterial efficiency of the mixture. The addition of benzalkonium chloride to sodium hypochlorite at the critical micellar concentration reduced the contact angle by 51.2% and the surface energy by 53.4%, without affecting the free chloride content, cytotoxicity, or antibacterial properties of the mixture. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Shaw, Andrew D; Raghunathan, Karthik; Peyerl, Fred W; Munson, Sibyl H; Paluszkiewicz, Scott M; Schermer, Carol R
2014-12-01
Recent data suggest that both elevated serum chloride levels and volume overload may be harmful during fluid resuscitation. The purpose of this study was to examine the relationship between the intravenous chloride load and in-hospital mortality among patients with systemic inflammatory response syndrome (SIRS), with and without adjustment for the crystalloid volume administered. We conducted a retrospective analysis of 109,836 patients ≥ 18 years old that met criteria for SIRS and received fluid resuscitation with crystalloids. We examined the association between changes in serum chloride concentration, the administered chloride load and fluid volume, and the 'volume-adjusted chloride load' and in-hospital mortality. In general, increases in the serum chloride concentration were associated with increased mortality. Mortality was lowest (3.7%) among patients with minimal increases in serum chloride concentration (0-10 mmol/L) and when the total administered chloride load was low (3.5% among patients receiving 100-200 mmol; P < 0.05 versus patients receiving ≥ 500 mmol). After controlling for crystalloid fluid volume, mortality was lowest (2.6%) when the volume-adjusted chloride load was 105-115 mmol/L. With adjustment for severity of illness, the odds of mortality increased (1.094, 95% CI 1.062, 1.127) with increasing volume-adjusted chloride load (≥ 105 mmol/L). Among patients with SIRS, a fluid resuscitation strategy employing lower chloride loads was associated with lower in-hospital mortality. This association was independent of the total fluid volume administered and remained significant after adjustment for severity of illness, supporting the hypothesis that crystalloids with lower chloride content may be preferable for managing patients with SIRS.
Importance of Abnormal Chloride Homeostasis in Stable Chronic Heart Failure.
Grodin, Justin L; Verbrugge, Frederik H; Ellis, Stephen G; Mullens, Wilfried; Testani, Jeffrey M; Tang, W H Wilson
2016-01-01
The aim of this analysis was to determine the long-term prognostic value of lower serum chloride in patients with stable chronic heart failure. Electrolyte abnormalities are prevalent in patients with chronic heart failure. Little is known regarding the prognostic implications of lower serum chloride. Serum chloride was measured in 1673 consecutively consented stable patients with a history of heart failure undergoing elective diagnostic coronary angiography. All patients were followed for 5-year all-cause mortality, and survival models were adjusted for variables that confounded the chloride-risk relationship. The average chloride level was 102 ± 4 mEq/L. Over 6772 person-years of follow-up, there were 547 deaths. Lower chloride (per standard deviation decrease) was associated with a higher adjusted risk of mortality (hazard ratio 1.29, 95% confidence interval 1.12-1.49; P < 0.001). Chloride levels net-reclassified risk in 10.4% (P = 0.03) when added to a multivariable model (with a resultant C-statistic of 0.70), in which sodium levels were not prognostic (P = 0.30). In comparison to those with above first quartile chloride (≥ 101 mEq/L) and sodium (≥ 138 meq/L), subjects with first quartile chloride had a higher adjusted mortality risk, whether they had first quartile sodium (hazard ratio 1.35, 95% confidence interval 1.08-1.69; P = 0.008) or higher (hazard ratio 1.43, 95% confidence interval 1.12-1.85; P = 0.005). However, subjects with first quartile sodium but above first quartile chloride had no association with mortality (P = 0.67). Lower serum chloride levels are independently and incrementally associated with increased mortality risk in patients with chronic heart failure. A better understanding of the biological role of serum chloride is warranted. © 2015 American Heart Association, Inc.
The Importance of Abnormal Chloride Homeostasis in Stable Chronic Heart Failure
Grodin, Justin L.; Verbrugge, Frederik H.; Ellis, Stephen G.; Mullens, Wilfried; Testani, Jeffrey M.; Wilson Tang MD, W. H.
2015-01-01
Background The aim of this analysis was to determine the long-term prognostic value of lower serum chloride in patients with stable chronic heart failure. Electrolyte abnormalities are prevalent in patients with chronic heart failure. Little is known regarding the prognostic implications of lower serum chloride. Methods and Results Serum chloride was measured in 1,673 consecutively consented stable patients with a history of heart failure undergoing elective diagnostic coronary angiography. All patients were followed for 5-year all-cause mortality, and survival models were adjusted for variables that confounded the chloride-risk relationship. The average chloride level was 102±4 mEq/L. Over 6,772 person-years of follow-up, there were 547 deaths. Lower chloride (per standard deviation decrease) was associated with a higher adjusted risk of mortality (HR 1.29, 95%CI 1.12–1.49, P<0.001). Chloride levels net-reclassified risk in 10.4% (P=0.03) when added to a multivariable model (with a resultant C-statistic of 0.70), in which sodium levels were not prognostic (P=0.30). In comparison to those with above first quartile chloride (≥101 mEq/L) and sodium (≥138 meq/L), subjects with first quartile chloride had a higher adjusted mortality risk, whether they had first quartile sodium (HR 1.35, 95%CI 1.08–1.69, P=0.008) or higher (HR 1.43, 95%CI 1.12–1.85, P=0.005). However, subjects with first quartile sodium but above first quartile chloride had no association with mortality (P=0.67). Conclusions Lower serum chloride levels are independently and incrementally associated with increased mortality risk in patients with chronic heart failure. A better understanding of the biological role of serum chloride is warranted. PMID:26721916
Chloride Blood Test: MedlinePlus Lab Test Information
... https://medlineplus.gov/labtests/chloridebloodtest.html Chloride Blood Test To use the sharing features on this page, please enable JavaScript. What is a Chloride Blood Test? A chloride blood test measures the amount of ...
Kresse, Timothy M.; Clark, Brian R.
2008-01-01
Water-quality data from approximately 2,500 sites were used to investigate the distribution of chloride concentrations in the Mississippi River Valley alluvial aquifer in southeastern Arkansas. The large volume and areal distribution of the data used for the investigation proved useful in delineating areas of elevated (greater than 100 milligrams per liter) chloride concentrations, assessing potential sources of saline water, and evaluating trends in chloride distribution and concentration over time. Irrigation water containing elevated chloride concentrations is associated with negative effects to rice and soybeans, two of the major crops in Arkansas, and a groundwater chloride concentration of 100 milligrams per liter is recommended as the upper limit for use on rice. As such, accurately delineating areas with high salinity ground water, defining potential sources of chloride, and documenting trends over time is important in assisting the agricultural community in water management. The distribution and range of chloride concentrations in the study area revealed distinct areas of elevated chloride concentrations. Area I includes an elongated, generally northwest-southeast trending band of moderately elevated chloride concentrations in the northern part of the study area. This band of elevated chloride concentrations is approximately 40 miles in length and varies from approximately 2 to 9 miles in width, with a maximum chloride concentration of 360 milligrams per liter. Area II is a narrow, north-south trending band of elevated chloride concentrations in the southern part of the study area, with a maximum chloride concentration of 1,639 milligrams per liter. A zone of chloride concentrations exceeding 200 milligrams per liter is approximately 25 miles in length and 5 to 6 miles in width. In Area I, low chloride concentrations in samples from wells completed in the alluvial aquifer next to the Arkansas River and in samples from the upper Claiborne aquifer, which underlies the alluvial aquifer, indicate that leakage from the river and upward flow of saline water in underlying aquifers are not likely sources for the saline water in the alluvial aquifer in Area I. A good comparison was noted for chloride concentrations in Area I and surface geomorphology. In the majority of cases, elevated chloride concentrations occurred in backswamp deposits, with low concentrations (less than 50 milligrams per liter) in areas of active or abandoned channel deposits. The fine-grained, clay-rich deposits associated with backswamp areas likely restrict recharge, induce increased ratios between evapotranspiration and recharge, and experience minimal flushing of salts concentrated during evapotranspiration. In Area II, chloride isoconcentration maps of the underlying upper Claiborne aquifer, in addition to samples from wells completed in the middle and lower Claiborne aquifers, showed a similar chloride distribution to that of the alluvial aquifer with decreasing chloride concentrations to the east of the zone of elevated chloride concentrations, which suggests a deeper source of saline water that affects Tertiary and Quaternary aquifer systems. Mixing curves developed from bromide/chloride ratios in water samples from the alluvial aquifer, Tertiary aquifers, and samples of brine water from the Jurrasic Smackover Formation additionally discounted upward flow of saline water from underlying Tertiary formations as a potential mechanism for salinity in the alluvial aquifer in Area II. A review of information on oil exploration wells in Chicot County revealed that most of these wells were drilled from 1960 to 1980, after the elevated chloride concentrations were detected in the early 1950s. The elongated nature of the zone of elevated chloride concentrations in Area II suggests a line source or linear conduit connection with the source. Maps of a fractured limestone in the Smackover Formation in Arkansas, Mississippi, and Louisiana for purpose
1989-10-20
Phthalocyanines by Thionyl Chloride. Implications for Lithium /Thionyl Chloride Batteries By P.A. Bernstein and A.B.P. Lever* D T IC in NOV.0 3.1W9. M...Thionyl Chloride. Implications forI Lithium /Thionvl Chloride Batteries 12 PERSONAL AUTHOR(S) P.A. Bernstein and A.B.P. Lever* 13a. TYPE OF REPORT 13b...SUBJECT TERMS (Continue on reverse if necessary and identify by olock numoer) FIELD GROUP SUB-GROUP .’ Phthalocyanine," Lithium Battery, Thionyl
NASA Technical Reports Server (NTRS)
Hargittai, M.
1980-01-01
The structural chemistry of complexes between aluminum chloride and other metal chlorides is important both for practice and theory. Condensed-phase as well as vapor-phase complexes are of interest. Structural information on such complexes is reviewed. The first emphasis is given to the molten state because of its practical importance. Aluminum chloride forms volatile complexes with other metal chlorides and these vapor-phase complexes are dealt with in the second part. Finally, the variations in molecular shape and geometrical parameters are summarized.
Andreasen, D.C.; Fleck, W.B.
1997-01-01
Brackish water from Chesapeake Bay and its tributaries has entered the Aquia aquifer in east-central Anne Arundel County, Maryland, USA. This determination was made based on chloride analyses of water samples collected in wells screened in the Aquia aquifer between October 1988 and May 1989. The Aquia aquifer, which is composed of fine- to medium-grained sand, is a shallow, unconfined aquifer in this area. Land use is primarily urban, consisting of a mixture of residential and light commercial areas. Associated with the urban setting is the potential for chloride contamination to enter the Aquia aquifer from anthropogenic sources, such as residential septic-tank effluent, leaky public sewer lines, road-deicing salt, stormwater infiltration basins, and domestic water-conditioning recharge effluent. In order to map the distribution of bay-water intrusion in the Aquia aquifer, chloride derived from Chesapeake Bay was differentiated from chloride derived from anthropogenic sources by comparing the ratio of dissolved bromide to dissolved chloride (bromide:chloride) in groundwater to the distinctive ratio in Chesapeake Bay water. Two additional factors considered in determining the source of the chloride were nitrogen concentrations and well-screen positions of sampled wells in relation to the estimated depth of the fresh-water/brackish-water interface. Of 36 Aquia-aquifer water samples with chloride concentrations greater than 30 mg/L, 22 had bromide:chloride ratios similar to the ratio in Chesapeake Bay water, an indication that bay water is the primary source of the chloride. Of the other 14 samples with bromide:chloride ratios dissimilar to the ratio in Chesapeake Bay water, seven were from wells where screen positions were substantially above the estimated fresh-water/brackish-water interface. Three of these samples had nitrogen concentrations (as nitrite plus nitrate) greater than 3.0 mg/L, an indication that chloride in these groundwater samples comes from anthropogenic sources, at least in part.
The influence of the chloride gradient across red cell membranes on sodium and potassium movements
Cotterrell, D.; Whittam, R.
1971-01-01
1. A study has been made to see whether active and passive movements of sodium and potassium in human red blood cells are influenced by changing the chloride gradient and hence the potential difference across the cell membrane. 2. Chloride distribution was measured between red cells and isotonic solutions with a range of concentrations of chloride and non-penetrating anions (EDTA, citrate, gluconate). The cell chloride concentration was greater than that outside with low external chloride, suggesting that the sign of the membrane potential was reversed. The chloride ratio (internal/external) was approximately equal to the inverse of the hydrogen ion ratio at normal and low external chloride, and inversely proportional to external pH. These results show that chloride is passively distributed, making it valid to calculate the membrane potential from the chloride ratio. 3. Ouabain-sensitive (pump) potassium influx and sodium efflux were decreased by not more than 20 and 40% respectively on reversing the chloride gradient, corresponding to a change in membrane potential from -9 to +30 mV. In contrast, passive (ouabain-insensitive) movements were reversibly altered — potassium influx was decreased about 60% and potassium efflux was increased some tenfold. Sodium influx was unaffected by the nature of the anion and depended only on the external sodium concentration, whereas ouabain-insensitive sodium efflux was increased about threefold. When external sodium was replaced by potassium there was a decrease in ouabain-insensitive sodium efflux with normal chloride, but an increase in low-chloride medium. 4. Net movements of sodium and potassium were roughly in accord with the unidirectional fluxes. 5. The results suggest that reversing the chloride gradient and, therefore, the sign of the membrane potential, had little effect on the sodium pump, but caused a marked increase in passive outward movements of both sodium and potassium ions. PMID:4996368
Chloride Fluxes in Isolated Dialyzed Barnacle Muscle Fibers
DiPolo, R.
1972-01-01
Chloride outflux and influx has been studied in single isolated muscle fibers from the giant barnacle under constant internal composition by means of a dialysis perfusion technique. Membrane potential was continually recorded. The chloride outfluxes and influxes were 143 and 144 pmoles/cm2-sec (mean resting potential: 58 mv, temperature: 22°–24°C) with internal and external chloride concentrations of 30 and 541 mM, respectively. The chloride conductance calculated from tracer measurements using constant field assumptions is about fourfold greater than that calculated from published electrical data. Replacing 97% of the external chloride ions by propionate reduces the chloride efflux by 51%. Nitrate ions applied either to the internal or external surface of the membrane slows the chloride efflux. The external pH dependence of the chloride efflux follows the external pH dependence of the membrane conductance, in the range pH 3.9–4.7, increasing with decreasing pH. In the range pH 5–9, the chloride efflux increased with increasing pH, in a manner similar to that observed in frog muscle fibers. The titration curve for internal pH changes in the range 4.0–7.0 was quantitatively much different from that for external pH change, indicating significant asymmetry in the internal and external pH dependence of the chloride efflux. PMID:5074810
Chloride channels as drug targets
Verkman, Alan S.; Galietta, Luis J. V.
2013-01-01
Chloride channels represent a relatively under-explored target class for drug discovery as elucidation of their identity and physiological roles has lagged behind that of many other drug targets. Chloride channels are involved in a wide range of biological functions, including epithelial fluid secretion, cell-volume regulation, neuroexcitation, smooth-muscle contraction and acidification of intracellular organelles. Mutations in several chloride channels cause human diseases, including cystic fibrosis, macular degeneration, myotonia, kidney stones, renal salt wasting and hyperekplexia. Chloride-channel modulators have potential applications in the treatment of some of these disorders, as well as in secretory diarrhoeas, polycystic kidney disease, osteoporosis and hypertension. Modulators of GABAA (γ-aminobutyric acid A) receptor chloride channels are in clinical use and several small-molecule chloride-channel modulators are in preclinical development and clinical trials. Here, we discuss the broad opportunities that remain in chloride-channel-based drug discovery. PMID:19153558
Salt, chloride, bleach, and innate host defense
Wang, Guoshun; Nauseef, William M.
2015-01-01
Salt provides 2 life-essential elements: sodium and chlorine. Chloride, the ionic form of chlorine, derived exclusively from dietary absorption and constituting the most abundant anion in the human body, plays critical roles in many vital physiologic functions, from fluid retention and secretion to osmotic maintenance and pH balance. However, an often overlooked role of chloride is its function in innate host defense against infection. Chloride serves as a substrate for the generation of the potent microbicide chlorine bleach by stimulated neutrophils and also contributes to regulation of ionic homeostasis for optimal antimicrobial activity within phagosomes. An inadequate supply of chloride to phagocytes and their phagosomes, such as in CF disease and other chloride channel disorders, severely compromises host defense against infection. We provide an overview of the roles that chloride plays in normal innate immunity, highlighting specific links between defective chloride channel function and failures in host defense. PMID:26048979
Mechanistic characterization of chloride interferences in electrothermal atomization systems
Shekiro, J.M.; Skogerboe, R.K.; Taylor, Howard E.
1988-01-01
A computer-controlled spectrometer with a photodiode array detector has been used for wavelength and temperature resolved characterization of the vapor produced by an electrothermal atomizer. The system has been used to study the chloride matrix interference on the atomic absorption spectrometric determination of manganese and copper. The suppression of manganese and copper atom populations by matrix chlorides such as those of calcium and magnesium is due to the gas-phase formation of an analyte chloride species followed by the diffusion of significant fractions of these species from the atom cell prior to completion of the atomization process. The analyte chloride species cannot be formed when matrix chlorides with metal-chloride bond dissociation energies above those of the analyte chlorides are the principal entitles present. The results indicate that multiple wavelength spectrometry used to obtain temperature-resolved spectra is a viable tool in the mechanistic characterization of interference effects observed with electrothermal atomization systems. ?? 1988 American Chemical Society.
High lumenal chloride in the lysosome is critical for lysosome function.
Chakraborty, Kasturi; Leung, KaHo; Krishnan, Yamuna
2017-07-25
Lysosomes are organelles responsible for the breakdown and recycling of cellular machinery. Dysfunctional lysosomes give rise to lysosomal storage disorders as well as common neurodegenerative diseases. Here, we use a DNA-based, fluorescent chloride reporter to measure lysosomal chloride in Caenorhabditis elegans as well as murine and human cell culture models of lysosomal diseases. We find that the lysosome is highly enriched in chloride, and that chloride reduction correlates directly with a loss in the degradative function of the lysosome. In nematodes and mammalian cell culture models of diverse lysosomal disorders, where previously only lysosomal pH dysregulation has been described, massive reduction of lumenal chloride is observed that is ~10 3 fold greater than the accompanying pH change. Reducing chloride within the lysosome impacts Ca 2+ release from the lysosome and impedes the activity of specific lysosomal enzymes indicating a broader role for chloride in lysosomal function.
Salt, chloride, bleach, and innate host defense.
Wang, Guoshun; Nauseef, William M
2015-08-01
Salt provides 2 life-essential elements: sodium and chlorine. Chloride, the ionic form of chlorine, derived exclusively from dietary absorption and constituting the most abundant anion in the human body, plays critical roles in many vital physiologic functions, from fluid retention and secretion to osmotic maintenance and pH balance. However, an often overlooked role of chloride is its function in innate host defense against infection. Chloride serves as a substrate for the generation of the potent microbicide chlorine bleach by stimulated neutrophils and also contributes to regulation of ionic homeostasis for optimal antimicrobial activity within phagosomes. An inadequate supply of chloride to phagocytes and their phagosomes, such as in CF disease and other chloride channel disorders, severely compromises host defense against infection. We provide an overview of the roles that chloride plays in normal innate immunity, highlighting specific links between defective chloride channel function and failures in host defense. © Society for Leukocyte Biology.
GOLDMAN, M; DEIBEL, R H; NIVEN, C F
1963-05-01
Goldman, Manuel (American Meat Institute Foundation, Chicago, Ill.), R. H. Deibel, and C. F. Niven, Jr. Interrelationship between temperature and sodium chloride on growth of lactic acid bacteria isolated from meat-curing brines. J. Bacteriol. 85:1017-1021. 1963.-An elevation of the temperature limit for growth of some Pediococcus homari (Gaffkya homari) and motile Lactobacillus strains could be effected by the addition of sodium chloride to the growth medium. At the optimal temperature for growth, sodium chloride was stimulatory, and as the temperature of incubation was increased a mandatory requirement for sodium chloride was manifested. At the optimal temperature for growth (30 C), the highest sodium chloride concentrations were tolerated; as the temperature was increased, this tolerance decreased, although the optimal sodium chloride concentration increased. No other substances were found that would replace the sodium chloride requirement at higher temperatures of incubation.
Goldman, Manuel; Deibel, R. H.; Niven, C. F.
1963-01-01
Goldman, Manuel (American Meat Institute Foundation, Chicago, Ill.), R. H. Deibel, and C. F. Niven, Jr. Interrelationship between temperature and sodium chloride on growth of lactic acid bacteria isolated from meat-curing brines. J. Bacteriol. 85:1017–1021. 1963.—An elevation of the temperature limit for growth of some Pediococcus homari (Gaffkya homari) and motile Lactobacillus strains could be effected by the addition of sodium chloride to the growth medium. At the optimal temperature for growth, sodium chloride was stimulatory, and as the temperature of incubation was increased a mandatory requirement for sodium chloride was manifested. At the optimal temperature for growth (30 C), the highest sodium chloride concentrations were tolerated; as the temperature was increased, this tolerance decreased, although the optimal sodium chloride concentration increased. No other substances were found that would replace the sodium chloride requirement at higher temperatures of incubation. PMID:14043988
Code of Federal Regulations, 2011 CFR
2011-10-01
... 43 Public Lands: Interior 2 2011-10-01 2011-10-01 false If I am mining calcium chloride, may I... Lease Terms and Conditions § 3511.11 If I am mining calcium chloride, may I obtain a noncompetitive mineral lease to produce the commingled sodium chloride? Yes. If you are producing calcium chloride in...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 43 Public Lands: Interior 2 2014-10-01 2014-10-01 false If I am mining calcium chloride, may I... Lease Terms and Conditions § 3511.11 If I am mining calcium chloride, may I obtain a noncompetitive mineral lease to produce the commingled sodium chloride? Yes. If you are producing calcium chloride in...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 43 Public Lands: Interior 2 2013-10-01 2013-10-01 false If I am mining calcium chloride, may I... Lease Terms and Conditions § 3511.11 If I am mining calcium chloride, may I obtain a noncompetitive mineral lease to produce the commingled sodium chloride? Yes. If you are producing calcium chloride in...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 43 Public Lands: Interior 2 2012-10-01 2012-10-01 false If I am mining calcium chloride, may I... Lease Terms and Conditions § 3511.11 If I am mining calcium chloride, may I obtain a noncompetitive mineral lease to produce the commingled sodium chloride? Yes. If you are producing calcium chloride in...
Ozgurel, O; Pauzat, F; Pilmé, J; Ellinger, Y; Bacchus-Montabonel, M-C; Mousis, O
2017-10-07
The deficiencies of argon, krypton, and xenon observed in the atmosphere of Titan as well as anticipated in some comets might be related to a scenario of sequestration by H 3 + in the gas phase at the early evolution of the solar nebula. The chemical process implied is a radiative association, evaluated as rather efficient in the case of H 3 + , especially for krypton and xenon. This mechanism of chemical trapping might not be limited to H 3 + only, considering that the protonated ions produced in the destruction of H 3 + by its main competitors present in the primitive nebula, i.e., H 2 O, CO, and N 2 , might also give stable complexes with the noble gases. However the effective efficiency of such processes is still to be proven. Here, the reactivity of the noble gases Ar, Kr, and Xe, with all protonated ions issued from H 2 O, CO, and N 2 , expected to be present in the nebula with reasonably high abundances, has been studied with quantum simulation method dynamics included. All of them give stable complexes and the rate coefficients of their radiative associations range from 10 -16 to 10 -19 cm 3 s -1 , which is reasonable for such reactions and has to be compared to the rates of 10 -16 to 10 -18 cm 3 s -1 , obtained with H 3 + . We can consider this process as universal for all protonated ions which, if present in the primitive nebula as astrophysical models predict, should act as sequestration agents for all three noble gases with increasing efficiency from Ar to Xe.
Pathway to Cryogen Free Production of Hyperpolarized Krypton-83 and Xenon-129
Six, Joseph S.; Hughes-Riley, Theodore; Stupic, Karl F.; Pavlovskaya, Galina E.; Meersmann, Thomas
2012-01-01
Hyperpolarized (hp) 129Xe and hp 83Kr for magnetic resonance imaging (MRI) are typically obtained through spin-exchange optical pumping (SEOP) in gas mixtures with dilute concentrations of the respective noble gas. The usage of dilute noble gases mixtures requires cryogenic gas separation after SEOP, a step that makes clinical and preclinical applications of hp 129Xe MRI cumbersome. For hp 83Kr MRI, cryogenic concentration is not practical due to depolarization that is caused by quadrupolar relaxation in the condensed phase. In this work, the concept of stopped flow SEOP with concentrated noble gas mixtures at low pressures was explored using a laser with 23.3 W of output power and 0.25 nm linewidth. For 129Xe SEOP without cryogenic separation, the highest obtained MR signal intensity from the hp xenon-nitrogen gas mixture was equivalent to that arising from 15.5±1.9% spin polarized 129Xe in pure xenon gas. The production rate of the hp gas mixture, measured at 298 K, was 1.8 cm3/min. For hp 83Kr, the equivalent of 4.4±0.5% spin polarization in pure krypton at a production rate of 2 cm3/min was produced. The general dependency of spin polarization upon gas pressure obtained in stopped flow SEOP is reported for various noble gas concentrations. Aspects of SEOP specific to the two noble gas isotopes are discussed and compared with current theoretical opinions. A non-linear pressure broadening of the Rb D1 transition was observed and taken into account for the qualitative description of the SEOP process. PMID:23209620
DOE Office of Scientific and Technical Information (OSTI.GOV)
Demkowicz, Paul A.; Reber, Edward L.; Scates, Dawn M.
2015-09-01
Three TRISO fuel compacts from the AGR-1 irradiation experiment were subjected to safety tests at 1600 and 1800 °C for approximately 300 h to evaluate the fission product retention characteristics. Silver behavior was dominated by rapid release of an appreciable fraction of the compact inventory (3–34%) at the beginning of the tests, believed to be from inventory residing in the compact matrix and outer pyrocarbon (OPyC) prior to the safety test. Measurable release of silver from intact particles appears to become apparent only after ~60 h at 1800 °C. The release rate for europium and strontium was nearly constant formore » 300 h at 1600 °C (reaching maximum values of approximately 2×10⁻³ and 8×10⁻⁴ respectively), and at this temperature the release may be mostly limited to inventory in the compact matrix and OPyC prior to the safety test. The release rate for both elements increased after approximately 120 h at 1800 °C, possibly indicating additional measurable release through the intact particle coatings. Cesium fractional release from particles with intact coatings was <10⁻⁶ after 300 h at 1600 °C or 100 h at 1800 °C, but release from the rare particles that experienced SiC failure during the test could be significant. However, Kr release was still very low for 300 h 1600 °C (<2 × 10⁻⁶). At 1800 °C, krypton release increased noticeably after SiC failure, reflecting transport through the intact outer pyrocarbon layer. Nonetheless, the krypton and cesium release fractions remained less than approximately 10⁻³ after 277 h at 1800 °C.« less
Two photon absorption laser induced fluorescence measurements of neutral density in a helicon plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Galante, M. E.; Magee, R. M.; Scime, E. E.
2014-05-15
We have developed a new diagnostic based on two-photon absorption laser induced fluorescence (TALIF). We use a high intensity (5 MW/cm{sup 2}), narrow bandwidth (0.1 cm{sup −1}) laser to probe the ground state of neutral hydrogen, deuterium and krypton with spatial resolution better than 0.2 cm, a time resolution of 10 ns, and a measurement cadence of 20 Hz. Here, we describe proof-of-principle measurements in a helicon plasma source that demonstrate the TALIF diagnostic is capable of measuring neutral densities spanning four orders of magnitude; comparable to the edge neutral gradients predicted in the DIII-D tokamak pedestal. The measurements are performed in hydrogen and deuteriummore » plasmas and absolute calibration is accomplished through TALIF measurements in neutral krypton. The optical configuration employed is confocal, i.e., both light injection and collection are accomplished with a single lens through a single optical port in the vacuum vessel. The wavelength resolution of the diagnostic is sufficient to separate hydrogen and deuterium spectra and we present measurements from mixed hydrogen and deuterium plasmas that demonstrate isotopic abundance measurements are feasible. Time resolved measurements also allow us to explore the evolution of the neutral hydrogen density and temperature and effects of wall recycling. We find that the atomic neutral density grows rapidly at the initiation of the discharge, reaching the steady-state value within 1 ms. Additionally, we find that neutral hydrogen atoms are born with 0.08 eV temperatures, not 2 eV as is typically assumed.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knight L.B. Jr.; Cobranchi, S.T.; Petty, J.T.
1989-01-15
The first spectroscopic study of the diatomic radical BC is reported which confirms previous theoretical predictions of a /sup 4/summation/sup -/ electronic ground state. The nuclear hyperfine interactions (A tensors) obtained for /sup 11/B, /sup 10/B, and /sup 13/C from the electron spin resonance (ESR) measurements are compared with extensive ab initio CI calculations. The BC molecule is one of the first examples of a small high spin radical for such an in-depth experimental--theoretical comparison. The electronic structure of BC obtained from an analysis of the nuclear hyperfine interaction (hfi) is compared to that obtained from a Mulliken-type population analysismore » conducted on a CI wave function which yields A/sub iso/ and A/sub dip/ results in good agreement with the observed values. The BC radical was generated by the laser vaporization of a boron--carbon mixture and trapped in neon, argon, and krypton matrices at 4 K for a complete ESR characterization. The magnetic parameters (MHz) obtained for /sup 11/B/sup 13/C in solid neon are: g/sub parallel/ = 2.0015(3); g/sub perpendicular/ = 2.0020(3); D(zfs) = 1701(2); /sup 11/B: chemically bondA/sub parallel/chemically bond = 100(1); chemically bondA/sub perpendicular/chemically bond = 79(1); /sup 13/C: chemically bondA/sub parallel/chemically bond = 5(2) and chemically bondA/sub perpendicular/chemically bond = 15(1). Based on comparison with the theoretical results, the most likely choice of signs is that all A values are positive.« less
Adsorptive Separation and Sequestration of Krypton, I and C14 on Diamond Nanoparticles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghosh, Tushar; Loyalka, Sudarsha; Prelas, Mark
The objective of this research proposal was to address the separation and sequestration of Kr and I from each other using nano-sized diamond particles and retaining these in diamond until they decay to the background level or can be used as a byproduct. Following removal of Kr and I, an adsorbent will be used to adsorb and store CO2 from the CO2 rich stream. A Field Enhanced Diffusion with Optical Activation (FEDOA-a large scale process that takes advantage of thermal, electrical, and optical activation to enhance the diffusion of an element into diamond structure) was used to load Kr andmore » I on micron or nano sized particles having a larger relative surface area. The diamond particles can be further increased by doping it with boron followed by irradiation in a neutron flux. Previous studies showed that the hydrogen storage capacity could be increased significantly by using boron-doped irradiated diamond particles. Diamond powders were irradiated for a longer time by placing them in a quartz tube. The surface area was measured using a Quantachrome Autosorb system. No significant increase in the surface area was observed. Total surface area was about 1.7 m2/g. This suggests the existence of very minimal pores. Interestingly it showed hysteresis upon desorption. A reason for this may be strong interaction between the surface and the nitrogen molecules. Adsorption runs at higher temperatures did not show any adsorption of krypton on diamond. Use of a GC with HID detector to determine the adsorption capacity from the breakthrough curves was attempted, but experimental difficulties were encountered.« less
Results of the Massachusetts methylene chloride end-users survey.
Roelofs, Cora R; Ellenbecker, Michael J
2003-02-01
A survey of Massachusetts companies reporting use of methylene chloride between 1995 and 1999 was conducted to assess the status of industrial use of the chemical in 2000. Methylene chloride has had wide use in industry although it has been identified as potentially hazardous to exposed workers and the environment. New and tightened occupational and environmental regulations taking effect in the 1990s were hypothesized to have reduced use of the chemical in Massachusetts. Substitute technologies, especially aqueous cleaning, were expected to have replaced methylene chloride in many industries. Seventeen of the 21 Massachusetts manufacturing companies reporting use of over 10,000 lb/y of methylene chloride between 1995 and 1999 were surveyed by telephone regarding their experiences of methylene chloride use and elimination and/or replacement. Fifteen of the 17 companies had either eliminated (10) or reduced to below 10,000 lbs/yr (5) their use of methylene chloride at the time of the survey in 2000. Many of the surveyed companies moved to aqueous cleaning from methylene chloride degreasing operations. Environmental concerns were the most popular reason given for eliminating or reducing use of methylene chloride. Worker health and safety concerns, especially concern about compliance with the 1997 Occupational Safety and Health Administration methylene chloride standard, were also a motivation. In general, the companies associated many benefits and few problems with eliminating or reducing use of methylene chloride. Exposure reduction strategies based on toxics use reduction techniques appear to be feasible for many manufacturing companies. However, research should be conducted to assess the introduction of new hazards as a result of tightened regulations on methylene chloride.
Washing bridges to reduce chloride : interim report.
DOT National Transportation Integrated Search
2003-12-01
Chloride ions are known to promote the corrosion of steel in reinforced concrete. This project was undertaken to investigate the efficacy of washing, to reduce chloride content and chloride ion uptake. The project consists of a laboratory and a field...
Washing bridges to reduce chloride : final report.
DOT National Transportation Integrated Search
2005-07-01
Chloride ions are known to promote the corrosion of steel in reinforced concrete. This project was undertaken to investigate the efficacy of washing, to reduce existing chloride content and chloride ion uptake. The project consisted of a laboratory c...
Gahan, Chandra Sekhar; Sundkvist, Jan-Eric; Dopson, Mark; Sandström, Ake
2010-06-15
Biomining is the use of microorganisms to catalyze metal extraction from sulfide ores. However, the available water in some biomining environments has high chloride concentrations and therefore, chloride toxicity to ferrous oxidizing microorganisms has been investigated. Batch biooxidation of Fe(2+) by a Leptospirillum ferriphilum-dominated culture was completely inhibited by 12 g L(-1) chloride. In addition, the effects of chloride on oxidation kinetics in a Fe(2+) limited chemostat were studied. Results from the chemostat modeling suggest that the chloride toxicity was attributed to affects on the Fe(2+) oxidation system, pH homeostasis, and lowering of the proton motive force. Modeling showed a decrease in the maximum specific growth rate (micro(max)) and an increase in the substrate constant (K(s)) with increasing chloride concentrations, indicating an effect on the Fe(2+) oxidation system. The model proposes a lowered maintenance activity when the media was fed with 2-3 g L(-1) chloride with a concomitant drastic decrease in the true yield (Y(true)). This model helps to understand the influence of chloride on Fe(2+) biooxidation kinetics. 2010 Wiley Periodicals, Inc.
Enhanced hydrophilicity of chlorided aluminum oxide particulates
NASA Technical Reports Server (NTRS)
Cofer, W. R., III
1978-01-01
An enhancement of hydrophilicity for chlorided aluminas was demonstrated by the results obtained from gaseous H2O sorptions at 70-, 80-, and 86-percent relative humidity on alpha and gamma aluminum oxide particulates and on alpha and gamma aluminum oxide particulates with a chemisorbed surface chloride phase (produced by reactions of gaseous HCl + H2O on alumina). Continuous sorption histories for H2O on chlorided aluminas having specific surface areas that range from 7 to 227 sq m/g before chloriding indicated that initial sorption rates were directly linked to the extent of chemisorbed chlorided coverage and implied the same relationship for sorption capacities. The initial sorption rate on chlorided aluminas was found to be slower for the first exposure to H2O than for subsequent exposures (which reached equilibrated H2O coverages much faster), suggesting that slow chemical reactions between H2O and chlorided alumina may have been operative during initial exposures. Chlorided alumina particles were found to remain very hydrophilic (relative to nonchlorided analogs) for several H2O sorption/desorption cycles.
Moss, H A; Tebbs, S E; Faroqui, M H; Herbst, T; Isaac, J L; Brown, J; Elliott, T S
2000-11-01
In an attempt to overcome infections associated with central venous catheters, a new antiseptic central venous catheter coated with benzalkonium chloride on the internal and external surfaces has been developed and evaluated in a clinical trial. Patients (235) randomly received either a triple-lumen central venous catheter coated with benzalkonium chloride (117) or a polyurethane non-antiseptic catheter (118). The incidence of microbial colonization of both catheters and retained antiseptic activity of the benzalkonium chloride device following removal were determined. The benzalkonium chloride resulted in a significant reduction of the incidence of microbial colonization on both the internal and external catheter surfaces. The reduction in colonization was detected at both the intradermal (21 benzalkonium chloride catheters vs. 38 controls, P = 0.0016) and distal segments of the antiseptic-coated catheters. Following catheter removal retained activity was demonstrated in benzalkonium chloride catheters which had been in place for up to 12 days. No patients developed adverse reactions to the benzalkonium chloride catheters. The findings demonstrate that the benzalkonium chloride catheter significantly reduced the incidence of catheter-associated colonization.
Mullaney, John R.; Lorenz, David L.; Arntson, Alan D.
2009-01-01
A study of chloride in groundwater and surface water was conducted for the glacial aquifer system of the northern United States in forested, agricultural, and urban areas by analyzing data collected for the National Water-Quality Assessment Program from 1991 to 2004. Groundwater-quality data from a sampling of 1,329 wells in 19 states were analyzed. Chloride concentrations were greater than the secondary maximum contaminant level established by the U.S. Environmental Protection Agency of 250 milligrams per liter in 2.5 percent of samples from 797 shallow monitoring wells and in 1.7 percent of samples from 532 drinking-water supply wells. Water samples from shallow monitoring wells in urban areas had the largest concentration of chloride, followed by water samples from agricultural and forested areas (medians of 46, 12, and 2.9 milligrams per liter, respectively). An analysis of chloride:bromide ratios, by mass, and chloride concentrations compared to binary mixing curves for dilute groundwater, halite, sewage and animal waste, potassium chloride fertilizer, basin brines, seawater, and landfill leachate in samples from monitoring wells indicated multiple sources of chloride in samples from wells in urban areas and agricultural areas. Water from shallow monitoring wells in urban areas had the largest chloride:bromide ratio, and samples with chloride:bromide ratios greater than 1,000 and chloride concentrations greater than 100 milligrams per liter were dominated by halite; however, the samples commonly contained mixtures that indicated input from sewage or animal waste. Chloride:bromide ratios were significantly larger in samples from public-supply drinking-water wells than from private drinking-water wells, and ratios were significantly larger in all drinking-water wells in eastern and central regions of the glacial aquifer system than in west-central and western regions of the glacial aquifer system. Surface-water-quality data collected regularly during varying time periods from 1991-2004 from 100 basins dominated by forested, agricultural, or urban land in 15 states were analyzed to determine maximum measured chloride concentrations. Samples from 15 sites in east, central, and west-central areas, collected primarily in winter, had chloride concentrations higher than the U.S. Environmental Protection Agency recommended chronic criterion concentration for aquatic life of 230 milligrams per liter. Concentrations of chloride in base-flow samples were predictive of maximum measured chloride concentrations, indicating that inputs of chloride from groundwater and (or) point-source wastewater discharges increase the likelihood of samples exceeding the recommended chronic aquatic criterion. Multiple linear regression analyses showed that the density of major roads, potential evapotranspiration, and the percentage of annual runoff from saturated overland flow were significant factors in describing the range of maximum measured chloride concentrations in the basins studied. Chloride loads and yields were determined at 95 surface-water-monitoring stations in basins dominated by forested, agricultural, or urban land. Annual chloride yield was largest in the urban basins (median of 88 tons per square mile) and smallest in the forested basins (median of 6.4 tons per square mile). The median chloride yield in the agricultural basins was 15.4 tons per square mile. Multiple linear regression analyses showed that the density of highways (roads in U.S. highway system), the number of major wastewater discharges in the basin, potential evapotranspiration, and urban minus agricultural land area were significant factors in describing the range of average annual chloride yields. Upward trends in chloride loads were apparent in several urban basins for which additional long-term data were available. Increases in chloride loads over time may be related to a variety of factors, including increases in road area and consequent deicing, incr
Mechanism of sodium and chloride transport in the thin ascending limb of Henle.
Imai, M; Kokko, J P
1976-01-01
Our previous in vitro studies have disclosed that the thin ascending limb of Henle (tALH) possesses some unique membrane characteristics. In those studies we failed to demonstrated active transport of sodium chloride by the tALH, although it was shown that the isotopic permeability to sodium and chloride was unusually high. However, we did not examine the mechanisms by which the apparent high permeation of sodium chloride occurs. Thus the purpose of the present studies was to elucidate the mechanism of sodium chloride transport across the isolated tALH of the rabbit by conducting four different types of studies: (1) comparison of the observed chloride and sodium flux ratios to those predicted by Ussing's equation under imposed salt concentration gradients; (2) kinetic evaluation of chloride and sodium fluxes; (3) examination of the effect of bromide on the kinetics of chloride transport; and (4) experiments to test for the existence of exchange diffusion of chloride. In the first set of studies the predicted and the theoretical flux ratios of sodium were identical in those experiments in which sodium chloride was added either to the perfusate or to the bath. However, the observed chloride flux ratio, lumen-to-bath/bath-to-lumen, was significantly lower than that predicted from Ussing's equation when 100 mM sodium chloride was added to the bath. In the second set of experiments the apparent isotopic permeability for sodium and for chloride was measured under varying perfusate and bath NaCl concentrations. There was no statistical change in the apparent sodium permeability coefficient when the NaCl concentration was raised by varying increments from 85.5 to 309.5 mM. However, permeation of 36Cl decrease significantly with an increase in Cl from 73.6 to 598.6 mM. These events could be explained by a two component chloride transport process consisting of simple diffusion and a saturable facilitated diffusion process with a Vmax = 3.71 neq mm-1 min-1. In the third set of studies it was shown that bromide inhibits transport of chloride and that the magnitude of inhibition is dependent on chloride concentrations. The fourth set of studies ruled out the existence of exchange diffusion. In conclusion, these studies indicate that sodium transport across tALH is by simple passive diffusion, while chloride transport across tALH involves at least two mechanisms: (1) simple passive diffusion; and (2) a specific membrane interaction process (carrier-mediated) which is competitively inhibited by bromide. PMID:993330
IRIS Toxicological Review of Vinyl Chloride (Final Report ...
EPA is announcing the release of the final report, Toxicological Review of Vinyl Chloride: in support of the Integrated Risk Information System (IRIS). The updated Summary for Vinyl Chloride and accompanying Quickview have also been added to the IRIS Database. Common synonyms of vinyl chloride (VC) include chloroethene, chloroethylene, ethylene monochloride, and monochloroethene. VC is a synthetic chemical used as a chemical intermediate in the polymerization of polyvinyl chloride.
A Quick Reference on Chloride.
Bohn, Andrea A; de Morais, Helio Autran
2017-03-01
Chloride is an essential element, playing important roles in digestion, muscular activity, regulation of body fluids, and acid-base balance. As the most abundant anion in extracellular fluid, chloride plays a major role in maintaining electroneutrality. Chloride is intrinsically linked to sodium in maintaining osmolality and fluid balance and has an inverse relationship with bicarbonate in maintaining acid-base balance. It is likely because of these close ties that chloride does not get the individual attention it deserves; we can use these facts to simplify and interpret changes in serum chloride concentrations. Copyright © 2016 Elsevier Inc. All rights reserved.
Chloride inhibition of nitrite uptake for non-teleost Actinopterygiian fishes.
Boudreaux, Perry J; Ferrara, Allyse M; Fontenot, Quenton C
2007-06-01
Fish that transport environmental chloride with a gill uptake mechanism (gill epithelial Cl(-)/HCO(3)(-)cotransport exchange system), also transport nitrite into plasma through the same mechanism. Because of the relationship between nitrite uptake and the gill chloride uptake mechanism, nitrite uptake can provide insight regarding the method of chloride uptake for fish. This study was designed to determine if non-teleost fishes concentrate nitrite in their plasma, and to determine if chloride inhibits nitrite uptake in non-teleost fish. To determine if bowfin Amia calva, spotted gar Lepisosteus oculatus, alligator gar Atractosteus spatula, and paddlefish Polyodon spathula concentrate environmental nitrite in their plasma, individuals were exposed to concentrations of 0, 1, 10, or 100 mg/L nitrite-N. After exposure, all species had plasma nitrite-N concentrations greater than environmental levels. To determine if chloride inhibits nitrite uptake for spotted gar, alligator gar, and paddlefish, fish were exposed to 1 mg/L nitrite-N and 20 mg/L chloride as calcium chloride, or to 1 mg/L nitrite-N only. Chloride effectively prevented nitrite from being concentrated in the plasma of all species. It appears that non-teleost fish concentrate nitrite in their plasma via their chloride uptake mechanism and that this is an ancestral characteristic for teleost.
Chloride Transport in Heterogeneous Formation
NASA Astrophysics Data System (ADS)
Mukherjee, A.; Holt, R. M.
2017-12-01
The chloride mass balance (CMB) is a commonly-used method for estimating groundwater recharge. Observations of the vertical distribution of pore-water chloride are related to the groundwater infiltration rates (i.e. recharge rates). In CMB method, the chloride distribution is attributed mainly to the assumption of one dimensional piston flow. In many places, however, the vertical distribution of chloride will be influenced by heterogeneity, leading to horizontal movement of infiltrating waters. The impact of heterogeneity will be particularly important when recharge is locally focused. When recharge is focused in an area, horizontal movement of chloride-bearing waters, coupled with upward movement driven by evapotranspiration, may lead to chloride bulges that could be misinterpreted if the CMB method is used to estimate recharge. We numerically simulate chloride transport and evaluate the validity of the CMB method in highly heterogeneous systems. This simulation is conducted for the unsaturated zone of Ogallala, Antlers, and Gatuna (OAG) formations in Andrews County, Texas. A two dimensional finite element model will show the movement of chloride through heterogeneous systems. We expect to see chloride bulges not only close to the surface but also at depths characterized by horizontal or upward movement. A comparative study of focused recharge estimates in this study with available recharge data will be presented.
Detecting the Water-soluble Chloride Distribution of Cement Paste in a High-precision Way.
Chang, Honglei; Mu, Song
2017-11-21
To improve the accuracy of the chloride distribution along the depth of cement paste under cyclic wet-dry conditions, a new method is proposed to obtain a high-precision chloride profile. Firstly, paste specimens are molded, cured, and exposed to cyclic wet-dry conditions. Then, powder samples at different specimen depths are grinded when the exposure age is reached. Finally, the water-soluble chloride content is detected using a silver nitrate titration method, and chloride profiles are plotted. The key to improving the accuracy of the chloride distribution along the depth is to exclude the error in the powderization, which is the most critical step for testing the distribution of chloride. Based on the above concept, the grinding method in this protocol can be used to grind powder samples automatically layer by layer from the surface inward, and it should be noted that a very thin grinding thickness (less than 0.5 mm) with a minimum error less than 0.04 mm can be obtained. The chloride profile obtained by this method better reflects the chloride distribution in specimens, which helps researchers to capture the distribution features that are often overlooked. Furthermore, this method can be applied to studies in the field of cement-based materials, which require high chloride distribution accuracy.
Soucek, David J; Dickinson, Amy
2016-09-01
While it has been well established that increasing chloride concentration in water reduces the toxicity of nitrite to freshwater species, little work has been done to investigate the effect of chloride on nitrate toxicity. We conducted acute and chronic nitrate (as sodium nitrate) toxicity tests with the cladoceran Ceriodaphnia dubia and the amphipod Hyalella azteca (chronic tests only) over a range of chloride concentrations spanning natural chloride levels found in surface waters representative of watersheds of the Great Lakes Region. Chronic nitrate toxicity test results with both crustaceans were variable, with H. azteca appearing to be one of the more sensitive invertebrate species tested and C. dubia being less sensitive. While the variability in results for H. azteca were to an extent related to chloride concentration in test water that was distinctly not the case for C. dubia. We concluded that the chloride dependent toxicity of nitrate is not universal among freshwater crustaceans. An additional sodium chloride chronic toxicity test with the US Lab strain of H. azteca in the present study suggested that when present as predominantly sodium chloride and with relatively low concentrations of other ions, there is a narrow range of chloride concentrations over which this strain is most fit, and within which toxicity test data are reliable.
Besada, Cristina; Gil, Rebeca; Bonet, Luis; Quiñones, Ana; Intrigliolo, Diego; Salvador, Alejandra
2016-03-01
In recent years many hectares planted with persimmon trees in E Spain have been diagnosed with chloride toxicity. An effect of this abiotic stress on fruit quality has been reported in different crops. However, the impact of chloride stress on persimmon fruit quality is unknown. The harvest and postharvest quality of persimmons harvested from trees that manifest different intensities of chloride toxicity foliar symptoms was evaluated herein. Our results revealed that fruits from trees under chloride stress conditions underwent chloride accumulation in the calyx, which was more marked the greater the salt stress intensity trees were exposed to. Increased chloride concentrations in the calyx stimulated ethylene production in this tissue. In the fruits affected by slight and moderate chloride stress, calyx ethylene production accelerated the maturity process, as reflected by increased fruit colour and diminished fruit firmness. In the fruits under severe chloride stress, the high ethylene levels in the calyx triggered autocatalytic ethylene production in other fruit tissues, which led fruit maturity to drastically advance. In these fruits effectiveness of CO2 deastringency treatment was not complete and fruit softening enhanced during the postharvest period. Moreover, chloride stress conditions had a marked effect on reducing fruit weight, even in slightly stressed trees. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Catalytic conversion of cellulose to levulinic acid by metal chlorides.
Peng, Lincai; Lin, Lu; Zhang, Junhua; Zhuang, Junping; Zhang, Beixiao; Gong, Yan
2010-08-02
The catalytic performance of various metal chlorides in the conversion of cellulose to levulinic acid in liquid water at high temperatures was investigated. The effects of reaction parameters on the yield of levulinic acid were also explored. The results showed that alkali and alkaline earth metal chlorides were not effective in conversion of cellulose, while transition metal chlorides, especially CrCl(3), FeCl(3) and CuCl(2) and a group IIIA metal chloride (AlCl(3)), exhibited high catalytic activity. The catalytic performance was correlated with the acidity of the reaction system due to the addition of the metal chlorides, but more dependent on the type of metal chloride. Among those metal chlorides, chromium chloride was found to be exceptionally effective for the conversion of cellulose to levulinic acid, affording an optimum yield of 67 mol % after a reaction time of 180 min, at 200 degrees C, with a catalyst dosage of 0.02 M and substrate concentration of 50 wt %. Chromium metal, most of which was present in its oxide form in the solid sample and only a small part in solution as Cr3+ ion, can be easily separated from the resulting product mixture and recycled. Finally, a plausible reaction scheme for the chromium chloride catalyzed conversion of cellulose in water was proposed.
Review on the significance of chlorine for crop yield and quality.
Geilfus, Christoph-Martin
2018-05-01
The chloride concentration in the plant determines yield and quality formation for two reasons. First, chlorine is a mineral nutrient and deficiencies thereof induce metabolic problems that interfere with growth. However, due to low requirement of most crops, deficiency of chloride hardly appears in the field. Second, excess of chloride, an event that occurs under chloride-salinity, results in severe physiological dysfunctions impairing both quality and yield formation. The chloride ion can effect quality of plant-based products by conferring a salty taste that decreases market appeal of e.g. fruit juices and beverages. However, most of the quality impairments are based on physiological dysfunctions that arise under conditions of chloride-toxicity: Shelf life of persimmon is shortened due to an autocatalytic ethylene production in fruit tissues. High concentrations of chloride in the soil can increase phyto-availability of the heavy metal cadmium, accumulating in wheat grains above dietary intake thresholds. When crops are cultivated on soils that are moderately salinized by chloride, nitrate fertilization might be a strategy to suppress uptake of chloride by means of an antagonistic anion-anion uptake competition. Overall, knowledge about proteins that catalyse chloride-efflux out of the roots or that restrict xylem loading is needed to engineer more resistant crops. Copyright © 2018 Elsevier B.V. All rights reserved.
Reddy, M.M.; Reddy, M.B.; Kipp, K.L.; Burman, A.; Schuster, P.; Rawlik, P.S.
2008-01-01
Water quality is a key aspect of the Everglades Restoration Project, the largest water reclamation and ecosystem management project proposed in the United States. Movement of nutrients and contaminants to and from Everglades peat porewater could have important consequences for Everglades water quality and ecosystem restoration activities. In a study of Everglades porewater, we observed complex, seasonally variable peat porewater chloride concentration profiles at several locations. Analyses and interpretation of these changing peat porewater chloride concentration profiles identifies processes controlling conservative solute movement at the peat-surface water interface, that is, solutes whose transport is minimally affected by chemical and biological reactions. We examine, with an advection-diffusion model, how alternating wet and dry climatic conditions in the Florida Everglades mediate movement of chloride between peat porewater and marsh surface water. Changing surface water-chloride concentrations alter gradients at the interface between peat and overlying water and hence alter chloride flux across that interface. Surface water chloride concentrations at two frequently monitored sites vary with marsh water depth, and a transfer function was developed to describe daily marsh surface water chloride concentration as a function of marsh water depth. Model results demonstrate that porewater chloride concentrations are driven by changing surface water chloride concentrations, and a sensitivity analysis suggests that inclusion of advective transport in the model improves the agreement between the calculated and the observed chloride concentration profiles. Copyright ?? 2007 John Wiley & Sons, Ltd.
Influence of Chloride-Ion Adsorption Agent on Chloride Ions in Concrete and Mortar.
Peng, Gai-Fei; Feng, Nai-Qian; Song, Qi-Ming
2014-04-30
The influence of a chloride-ion adsorption agent (Cl agent in short), composed of zeolite, calcium aluminate hydrate and calcium nitrite, on the ingress of chloride ions into concrete and mortar has been experimentally studied. The permeability of concrete was measured, and the chloride ion content in mortar was tested. The experimental results reveal that the Cl agent could adsorb chloride ions effectively, which had penetrated into concrete and mortar. When the Cl agent was used at a dosage of 6% by mass of cementitious materials in mortar, the resistance to the penetration of chloride ions could be improved greatly, which was more pronounced when a combination of the Cl agent and fly ash or slag was employed. Such an effect is not the result of the low permeability of the mortar, but might be a result of the interaction between the Cl agent and the chloride ions penetrated into the mortar. There are two possible mechanisms for the interaction between the Cl agent and chloride ion ingress. One is the reaction between calcium aluminate hydrate in the Cl agent and chloride ions to form Friedel's salt, and the other one is that calcium aluminate hydrate reacts with calcium nitrite to form AFm during the early-age hydration of mortar and later the NO₂ - in AFm is replaced by chloride ions, which then penetrate into the mortar, also forming Friedel's salt. More research is needed to confirm the mechanisms.
Influence of Chloride-Ion Adsorption Agent on Chloride Ions in Concrete and Mortar
Peng, Gai-Fei; Feng, Nai-Qian; Song, Qi-Ming
2014-01-01
The influence of a chloride-ion adsorption agent (Cl agent in short), composed of zeolite, calcium aluminate hydrate and calcium nitrite, on the ingress of chloride ions into concrete and mortar has been experimentally studied. The permeability of concrete was measured, and the chloride ion content in mortar was tested. The experimental results reveal that the Cl agent could adsorb chloride ions effectively, which had penetrated into concrete and mortar. When the Cl agent was used at a dosage of 6% by mass of cementitious materials in mortar, the resistance to the penetration of chloride ions could be improved greatly, which was more pronounced when a combination of the Cl agent and fly ash or slag was employed. Such an effect is not the result of the low permeability of the mortar, but might be a result of the interaction between the Cl agent and the chloride ions penetrated into the mortar. There are two possible mechanisms for the interaction between the Cl agent and chloride ion ingress. One is the reaction between calcium aluminate hydrate in the Cl agent and chloride ions to form Friedel’s salt, and the other one is that calcium aluminate hydrate reacts with calcium nitrite to form AFm during the early-age hydration of mortar and later the NO2− in AFm is replaced by chloride ions, which then penetrate into the mortar, also forming Friedel’s salt. More research is needed to confirm the mechanisms. PMID:28788625
40 CFR 415.40 - Applicability; description of the calcium chloride production subcategory.
Code of Federal Regulations, 2011 CFR
2011-07-01
... calcium chloride production subcategory. 415.40 Section 415.40 Protection of Environment ENVIRONMENTAL... SOURCE CATEGORY Calcium Chloride Production Subcategory § 415.40 Applicability; description of the calcium chloride production subcategory. The provisions of this subpart are applicable to discharges...
40 CFR 415.500 - Applicability; description of the potassium chloride production subcategory.
Code of Federal Regulations, 2013 CFR
2013-07-01
... potassium chloride production subcategory. 415.500 Section 415.500 Protection of Environment ENVIRONMENTAL... SOURCE CATEGORY Potassium Chloride Production Subcategory § 415.500 Applicability; description of the potassium chloride production subcategory. The provisions of this subpart are applicable to discharges...
40 CFR 415.500 - Applicability; description of the potassium chloride production subcategory.
Code of Federal Regulations, 2012 CFR
2012-07-01
... potassium chloride production subcategory. 415.500 Section 415.500 Protection of Environment ENVIRONMENTAL... SOURCE CATEGORY Potassium Chloride Production Subcategory § 415.500 Applicability; description of the potassium chloride production subcategory. The provisions of this subpart are applicable to discharges...
40 CFR 415.500 - Applicability; description of the potassium chloride production subcategory.
Code of Federal Regulations, 2010 CFR
2010-07-01
... potassium chloride production subcategory. 415.500 Section 415.500 Protection of Environment ENVIRONMENTAL... SOURCE CATEGORY Potassium Chloride Production Subcategory § 415.500 Applicability; description of the potassium chloride production subcategory. The provisions of this subpart are applicable to discharges...
49 CFR 173.322 - Ethyl chloride.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 2 2010-10-01 2010-10-01 false Ethyl chloride. 173.322 Section 173.322 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... SHIPMENTS AND PACKAGINGS Gases; Preparation and Packaging § 173.322 Ethyl chloride. Ethyl chloride must be...
40 CFR 415.40 - Applicability; description of the calcium chloride production subcategory.
Code of Federal Regulations, 2010 CFR
2010-07-01
... calcium chloride production subcategory. 415.40 Section 415.40 Protection of Environment ENVIRONMENTAL... SOURCE CATEGORY Calcium Chloride Production Subcategory § 415.40 Applicability; description of the calcium chloride production subcategory. The provisions of this subpart are applicable to discharges...
40 CFR 415.500 - Applicability; description of the potassium chloride production subcategory.
Code of Federal Regulations, 2011 CFR
2011-07-01
... potassium chloride production subcategory. 415.500 Section 415.500 Protection of Environment ENVIRONMENTAL... SOURCE CATEGORY Potassium Chloride Production Subcategory § 415.500 Applicability; description of the potassium chloride production subcategory. The provisions of this subpart are applicable to discharges...
40 CFR 415.500 - Applicability; description of the potassium chloride production subcategory.
Code of Federal Regulations, 2014 CFR
2014-07-01
... potassium chloride production subcategory. 415.500 Section 415.500 Protection of Environment ENVIRONMENTAL... SOURCE CATEGORY Potassium Chloride Production Subcategory § 415.500 Applicability; description of the potassium chloride production subcategory. The provisions of this subpart are applicable to discharges...
40 CFR 415.40 - Applicability; description of the calcium chloride production subcategory.
Code of Federal Regulations, 2012 CFR
2012-07-01
... calcium chloride production subcategory. 415.40 Section 415.40 Protection of Environment ENVIRONMENTAL... SOURCE CATEGORY Calcium Chloride Production Subcategory § 415.40 Applicability; description of the calcium chloride production subcategory. The provisions of this subpart are applicable to discharges...
40 CFR 415.40 - Applicability; description of the calcium chloride production subcategory.
Code of Federal Regulations, 2013 CFR
2013-07-01
... calcium chloride production subcategory. 415.40 Section 415.40 Protection of Environment ENVIRONMENTAL... SOURCE CATEGORY Calcium Chloride Production Subcategory § 415.40 Applicability; description of the calcium chloride production subcategory. The provisions of this subpart are applicable to discharges...
40 CFR 415.40 - Applicability; description of the calcium chloride production subcategory.
Code of Federal Regulations, 2014 CFR
2014-07-01
... calcium chloride production subcategory. 415.40 Section 415.40 Protection of Environment ENVIRONMENTAL... SOURCE CATEGORY Calcium Chloride Production Subcategory § 415.40 Applicability; description of the calcium chloride production subcategory. The provisions of this subpart are applicable to discharges...
Zhang, Chao; Jia, Yongzhong; Jing, Yan; Wang, Huaiyou; Hong, Kai
2014-08-01
The infrared spectrum of deep eutectic solvent of choline chloride and magnesium chloride hexahydrate was measured by the FTIR spectroscopy and analyzed with the aid of DFT calculations. The main chemical species and molecular structure in deep eutectic solvent of [MgClm(H2O)6-m]2-m and [ChxCly]x+y complexes were mainly identified and the active ion of magnesium complex during the electrochemical process was obtained. The mechanism of the electrochemical process of deep eutectic solvent of choline chloride and magnesium chloride hexahydrate was well explained by combination theoretical calculations and experimental. Besides, based on our results we proposed a new system for the dehydration study of magnesium chloride hexahydrate.
Antiviral effect of lithium chloride on infection of cells by canine parvovirus.
Zhou, Pei; Fu, Xinliang; Yan, Zhongshan; Fang, Bo; Huang, San; Fu, Cheng; Hong, Malin; Li, Shoujun
2015-11-01
Canine parvovirus type 2 causes significant viral disease in dogs, with high morbidity, high infectivity, and high mortality. Lithium chloride is a potential antiviral drug for viruses. We determined the antiviral effect of Lithium Chloride on canine parvovirus type 2 in feline kidney cells. The viral DNA and proteins of canine parvovirus were suppressed in a dose-dependent manner by lithium chloride. Further investigation verified that viral entry into cells was inhibited in a dose-dependent manner by lithium chloride. These results indicated that lithium chloride could be a potential antiviral drug for curing dogs with canine parvovirus infection. The specific steps of canine parvovirus entry into cells that are affected by lithium chloride and its antiviral effect in vivo should be explored in future studies.
Skin sterility after application of ethyl chloride spray.
Polishchuk, Daniil; Gehrmann, Robin; Tan, Virak
2012-01-18
Ethyl chloride topical anesthetic spray is labeled as nonsterile, yet it is widely used during injection procedures performed in an outpatient setting. The purpose of this study was to investigate the sterility of ethyl chloride topical anesthetic spray applied before an injection. Our a priori hypothesis was that application of the spray after the skin has been prepared would not alter the sterility of the injection site. We conducted a prospective, blinded, controlled study to assess the effect of ethyl chloride spray on skin sterility. Fifteen healthy adult subjects (age, twenty-three to sixty-one years) were prepared for mock injections into both shoulders and both knees, although no injection was actually performed. Three culture samples were obtained from each site on the skin: one before skin preparation with isopropyl alcohol, one after skin preparation and before application of ethyl chloride, and one after ethyl chloride had been sprayed on the site. In addition, the sterility of the ethyl chloride was tested directly by inoculating cultures with spray from the bottles. Growth occurred in 70% of the samples obtained before skin preparation, 3% of the samples obtained after skin preparation but before application of ethyl chloride, and 5% of the samples obtained after the injection site had been sprayed with ethyl chloride. The percentage of positive cultures did not increase significantly after application of ethyl chloride (p = 0.65). Spraying of ethyl chloride directly on agar plates resulted in growth on 13% of these plates compared with 11% of the control plates; this difference was also not significant (p = 0.80). Although ethyl chloride spray is not sterile, its application did not alter the sterility of the injection sites in the shoulder and knee.
Ferreira, João Pedro; Girerd, Nicolas; Duarte, Kevin; Coiro, Stefano; McMurray, John J V; Dargie, Henry J; Pitt, Bertram; Dickstein, Kenneth; Testani, Jeffrey M; Zannad, Faiez; Rossignol, Patrick
2017-02-01
Serum chloride levels were recently found to be independently associated with mortality in heart failure (HF). We investigated the relationship between serum chloride and clinical outcomes in 7195 subjects with acute myocardial infarction complicated by reduced left ventricular function and HF. The studied outcomes were all-cause mortality, cardiovascular mortality, and hospitalization for HF. Both chloride and sodium had a nonlinear association with the studied outcomes (P<0.05 for linearity). Patients in the lowest chloride tertile (chloride ≤100) were older, had more comorbidities, and had lower sodium levels (P<0.05 for all). Serum chloride showed a significant interaction with sodium with regard to all studied outcomes (P for interaction <0.05 for all). The lowest chloride tertile (≤100 mmol/L) was associated with increased mortality rates in the context of lower sodium (≤138 mmol/L; adjusted hazard ratio [95% confidence interval] for all-cause mortality=1.42 (1.14-1.77); P=0.002), whereas in the context of higher sodium levels (>141 mmol/L), the association with mortality was lost. Spline-transformed chloride and its interaction with sodium did not add significant prognostic information on top of other well-established prognostic variables (P>0.05 for all outcomes). In post-myocardial infarction with systolic dysfunction and HF, low serum chloride was associated with mortality (but not hospitalization for HF) in the setting of lower sodium. Overall, chloride and its interaction with sodium did not add clinically relevant prognostic information on top of other well-established prognostic variables. Taken together, these data support an integrated and critical consideration of chloride and sodium interplay. © 2017 American Heart Association, Inc.
Microbial reductive dehalogenation of vinyl chloride
Spormann, Alfred M [Stanford, CA; Muller, Jochen A [Baltimore, MD; Rosner, Bettina M [Berlin, DE; Von Abendroth, Gregory [Nannhein, DE; Meshulam-Simon, Galit [Los Altos, CA; McCarty, Perry L [Stanford, CA
2011-11-22
Compositions and methods are provided that relate to the bioremediation of chlorinated ethenes, particularly the bioremediation of vinyl chloride by Dehalococcoides-like organisms. An isolated strain of bacteria, Dehalococcoides sp. strain VS, that metabolizes vinyl chloride is provided; the genetic sequence of the enzyme responsible for vinyl chloride dehalogenation; methods of assessing the capability of endogenous organisms at an environmental site to metabolize vinyl chloride; and a method of using the strains of the invention for bioremediation.
Microbial reductive dehalogenation of vinyl chloride
Spormann, Alfred M [Stanford, CA; Muller, Jochen A [Baltimore, MD; Rosner, Bettina M [Berlin, DE; Von Abendroth, Gregory [Mannheim, DE; Meshulam-Simon, Galit [Los Angeles, CA; McCarty, Perry L [Stanford, CA
2014-02-11
Compositions and methods are provided that relate to the bioremediation of chlorinated ethenes, particularly the bioremediation of vinyl chloride by Dehalococcoides-like organisms. An isolated strain of bacteria, Dehalococcoides sp. strain VS, that metabolizes vinyl chloride is provided; the genetic sequence of the enzyme responsible for vinyl chloride dehalogenation; methods of assessing the capability of endogenous organisms at an environmental site to metabolize vinyl chloride; and a method of using the strains of the invention for bioremediation.
7 CFR 58.434 - Calcium chloride.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false Calcium chloride. 58.434 Section 58.434 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... Material § 58.434 Calcium chloride. Calcium chloride, when used, shall meet the requirements of the Food...
40 CFR 415.240 - Applicability; description of the ammonium chloride production subcategory.
Code of Federal Regulations, 2011 CFR
2011-07-01
... resulting from the production of ammonium chloride by the reaction of anhydrous ammonia with hydrogen... ammonium chloride production subcategory. 415.240 Section 415.240 Protection of Environment ENVIRONMENTAL... SOURCE CATEGORY Ammonium Chloride Production Subcategory § 415.240 Applicability; description of the...
7 CFR 58.434 - Calcium chloride.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 3 2010-01-01 2010-01-01 false Calcium chloride. 58.434 Section 58.434 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... Material § 58.434 Calcium chloride. Calcium chloride, when used, shall meet the requirements of the Food...
21 CFR 582.3845 - Stannous chloride.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Stannous chloride. 582.3845 Section 582.3845 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL....3845 Stannous chloride. (a) Product. Stannous chloride. (b) Tolerance. This substance is generally...
40 CFR 415.160 - Applicability; description of the sodium chloride production subcategory.
Code of Federal Regulations, 2010 CFR
2010-07-01
... sodium chloride production subcategory. 415.160 Section 415.160 Protection of Environment ENVIRONMENTAL... SOURCE CATEGORY Sodium Chloride Production Subcategory § 415.160 Applicability; description of the sodium chloride production subcategory. The provisions of this subpart are applicable to discharges resulting from...
40 CFR 415.10 - Applicability; description of the aluminum chloride production subcategory.
Code of Federal Regulations, 2010 CFR
2010-07-01
... aluminum chloride production subcategory. 415.10 Section 415.10 Protection of Environment ENVIRONMENTAL... SOURCE CATEGORY Aluminum Chloride Production Subcategory § 415.10 Applicability; description of the aluminum chloride production subcategory. The provisions of this subpart are applicable to discharges and...
46 CFR 154.1745 - Vinyl chloride: Transferring operations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Vinyl chloride: Transferring operations. 154.1745 Section 154.1745 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS... Operating Requirements § 154.1745 Vinyl chloride: Transferring operations. A vessel carrying vinyl chloride...
Antisense oligonucleotides suppress cell-volume-induced activation of chloride channels.
Gschwentner, M; Nagl, U O; Wöll, E; Schmarda, A; Ritter, M; Paulmichl, M
1995-08-01
Cell volume regulation is an essential feature of most cells. After swelling in hypotonic media, the simultaneous activation of potassium and chloride channels is believed to be the initial, time-determining step in cell volume regulation. The activation of both pathways is functionally linked and enables the cells to lose ions and water, subsequently leading to cell shrinkage and readjustment of the initial volume. NIH 3T3 fibroblasts efficiently regulate their volume after swelling and bear chloride channels that are activated by decreasing extracellular osmolarity. The chloride current elicited in these cells after swelling is reminiscent of the current found in oocytes expressing an outwardly rectifying chloride current termed ICln. Introduction of antisense oligodeoxynucleotides complementary to the first 30 nucleotides of the coding region of the ICln channel into NIH 3T3 fibroblasts suppresses the activation of the swelling-induced chloride current. The experiments directly demonstrate an unambiguous link between a volume-activated chloride current and a cloned protein involved in chloride transport.
Embedded fiber optic sensors for bridge deck chloride penetration measurements
NASA Astrophysics Data System (ADS)
Fuhr, Peter L.; Huston, Dryver R.; MacCraith, Brian D.
1998-04-01
The use of chloride-based deicing agents to help clear U.S. highways of roadway hazards leads to associated chemical related problems. Fouling of local rivers and streams due to runoff of the waterborne chlorides is significant and has contributed to local ordinances that are attempting to force state agencies to reduce, if not eliminate, the use of these chlorides (typically at the cost of increased driving hazards). With respect to the corrosion aspects of chloride application, cracks that occur in the roadway/bridge pavement allow water to seep into the pavement carrying the chloride to the rebar with the resultant increase in corrosion. The costs of this corrosion are considerable and have led to the wide- spread use of chloride/water impermeable membranes on roadways and especially within bridges. Fiber optics sensors have repeatedly been shown to provide measurement capabilities of parameters within such reinforced concrete structures. Development of fiber optic chloride sensors capable of being embedded within a roadway or bridge deck is reported.
High lumenal chloride in the lysosome is critical for lysosome function
Chakraborty, Kasturi; Leung, KaHo; Krishnan, Yamuna
2017-01-01
Lysosomes are organelles responsible for the breakdown and recycling of cellular machinery. Dysfunctional lysosomes give rise to lysosomal storage disorders as well as common neurodegenerative diseases. Here, we use a DNA-based, fluorescent chloride reporter to measure lysosomal chloride in Caenorhabditis elegans as well as murine and human cell culture models of lysosomal diseases. We find that the lysosome is highly enriched in chloride, and that chloride reduction correlates directly with a loss in the degradative function of the lysosome. In nematodes and mammalian cell culture models of diverse lysosomal disorders, where previously only lysosomal pH dysregulation has been described, massive reduction of lumenal chloride is observed that is ~103 fold greater than the accompanying pH change. Reducing chloride within the lysosome impacts Ca2+ release from the lysosome and impedes the activity of specific lysosomal enzymes indicating a broader role for chloride in lysosomal function. DOI: http://dx.doi.org/10.7554/eLife.28862.001 PMID:28742019
Method for the regeneration of spent molten zinc chloride
Zielke, Clyde W.; Rosenhoover, William A.
1981-01-01
In a process for regenerating spent molten zinc chloride which has been used in the hydrocracking of coal or ash-containing polynuclear aromatic hydrocarbonaceous materials derived therefrom and which contains zinc chloride, zinc oxide, zinc oxide complexes and ash-containing carbonaceous residue, by incinerating the spent molten zinc chloride to vaporize the zinc chloride for subsequent condensation to produce a purified molten zinc chloride: an improvement comprising the use of clay in the incineration zone to suppress the vaporization of metals other than zinc. Optionally water is used in conjunction with the clay to further suppress the vaporization of metals other than zinc.
Inhalation exposure to methylene chloride does not induce systemic immunotoxicity in rats.
Warbrick, E V; Kilgour, J D; Dearman, R J; Kimber, I; Dugard, P H
2003-07-11
Methylene chloride (dichloromethane) is used in a variety of industrial applications. To date, there has been no formal assessment of immunotoxicity attributed to methylene chloride. Studies were undertaken to examine whether methylene chloride has any potential to influence the integrity of immune function. For this purpose, Sprague-Dawley rats of both genders were exposed by inhalation to a single high dose (5000 ppm) of methylene chloride for 6 h/d, 5 d/wk for 28 d. This was considered the relevant route of administration, as not only is inhalation a primary route for human exposure to methylene chloride, but, also, the chemical is absorbed rapidly via the lungs. Under these conditions of exposure, methylene chloride failed to influence absolute or relative thymus weights in either gender and produced a significant reduction in relative, but not absolute, spleen weight in female rats only. Immunocompetence was measured as a function of the ability of treated animals to mount immunoglobulin M (IgM) antibody responses to sheep red blood cells (SRBC) as determined by enzyme-linked immunosorbent assay (ELISA). Exposure to methylene chloride did not affect antibody production. Evidence indicates that under these conditions of exposure, methylene chloride did not compromise immune function.
40 CFR 60.1935 - What equations must I use?
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Percent reduction in potential hydrogen chloride emissions. Calculate the percent reduction in potential hydrogen chloride emissions (%PHC1) using equation 3 of this section: ER06DE00.005 Where: %PHC1 = percent reduction of the potential hydrogen chloride emissions Ei = hydrogen chloride emission concentration as...
40 CFR 60.1935 - What equations must I use?
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Percent reduction in potential hydrogen chloride emissions. Calculate the percent reduction in potential hydrogen chloride emissions (%PHC1) using equation 3 of this section: ER06DE00.005 Where: %PHC1 = percent reduction of the potential hydrogen chloride emissions Ei = hydrogen chloride emission concentration as...
21 CFR 182.8252 - Choline chloride.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Choline chloride. 182.8252 Section 182.8252 Food... HUMAN CONSUMPTION (CONTINUED) SUBSTANCES GENERALLY RECOGNIZED AS SAFE Nutrients § 182.8252 Choline chloride. (a) Product. Choline chloride. (b) Conditions of use. This substance is generally recognized as...
21 CFR 182.8252 - Choline chloride.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Choline chloride. 182.8252 Section 182.8252 Food... HUMAN CONSUMPTION (CONTINUED) SUBSTANCES GENERALLY RECOGNIZED AS SAFE Nutrients § 182.8252 Choline chloride. (a) Product. Choline chloride. (b) Conditions of use. This substance is generally recognized as...
21 CFR 182.8252 - Choline chloride.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Choline chloride. 182.8252 Section 182.8252 Food... HUMAN CONSUMPTION (CONTINUED) SUBSTANCES GENERALLY RECOGNIZED AS SAFE Nutrients § 182.8252 Choline chloride. (a) Product. Choline chloride. (b) Conditions of use. This substance is generally recognized as...
21 CFR 182.8252 - Choline chloride.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Choline chloride. 182.8252 Section 182.8252 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) SUBSTANCES GENERALLY RECOGNIZED AS SAFE Nutrients § 182.8252 Choline chloride. (a) Product. Choline chloride. (b...
21 CFR 582.6193 - Calcium chloride.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Calcium chloride. 582.6193 Section 582.6193 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Calcium chloride. (a) Product. Calcium chloride. (b) Conditions of use. This substance is generally...
21 CFR 172.165 - Quaternary ammonium chloride combination.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Quaternary ammonium chloride combination. 172.165... HUMAN CONSUMPTION Food Preservatives § 172.165 Quaternary ammonium chloride combination. The food additive, quaternary ammonium chloride combination, may be safely used in food in accordance with the...
40 CFR 415.380 - Applicability; description of the ferric chloride production subcategory.
Code of Federal Regulations, 2010 CFR
2010-07-01
... ferric chloride production subcategory. 415.380 Section 415.380 Protection of Environment ENVIRONMENTAL... SOURCE CATEGORY Ferric Chloride Production Subcategory § 415.380 Applicability; description of the ferric chloride production subcategory. The provisions of this subpart are applicable to discharges and to the...
21 CFR 582.6193 - Calcium chloride.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Calcium chloride. 582.6193 Section 582.6193 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Calcium chloride. (a) Product. Calcium chloride. (b) Conditions of use. This substance is generally...
21 CFR 582.6193 - Calcium chloride.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Calcium chloride. 582.6193 Section 582.6193 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Calcium chloride. (a) Product. Calcium chloride. (b) Conditions of use. This substance is generally...
21 CFR 582.6193 - Calcium chloride.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Calcium chloride. 582.6193 Section 582.6193 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Calcium chloride. (a) Product. Calcium chloride. (b) Conditions of use. This substance is generally...
21 CFR 582.6193 - Calcium chloride.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 6 2014-04-01 2014-04-01 false Calcium chloride. 582.6193 Section 582.6193 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Calcium chloride. (a) Product. Calcium chloride. (b) Conditions of use. This substance is generally...
The effect of hypophysectomy on chloride balance in young-of-the-year bowfin, Amia calva.
Duff, D; Hanson, R; Fleming, W R
1987-01-01
The effect of hypophysectomy on chloride balance was examined in young-of-the-year bowfin, Amia calva. Hypophysectomy resulted in decreased serum and total body chloride levels but not in serum and total body sodium levels. Hypophysectomy resulted in decreased chloride influx with no effect on chloride efflux or sodium fluxes. Prolactin therapy reversed the effect of hypophysectomy on electrolyte balance but caused a significant reduction in serum protein.
Armaly, Ahlam M; Bar, Sukanta; Schindler, Corinna S
2017-08-04
The development of acid chlorides as formal dianion linchpin reagents that enable access to cyclic 2-alkyl- and 2-acyl-1,3-alkanediones from dicarboxylic acids is described herein. Mechanistic experiments relying on 13 C-labeling studies confirm the role of acid chlorides as carbon dianion linchpin reagents and have led to a revised reaction mechanism for the aluminum(III)-mediated Dieckmann cyclization of dicarboxylic acids with acid chlorides.
Acute Effects of (Bis)tributyltin Oxide on Marine Organisms. Summary of Work Performed 1981 to 1983
1989-05-01
Diethyltin chloride Dimethyltin chloride Diphenyltin chloride Hethyltin chloride Phenyltin chloride TBT - Tributyltin TBTA Tributyltin acetate TBTB...IW^I^^^—^M^—M—i^^^^I^M—^^——M— — O A OOI < Technical Report 1299 May 1989 .,..,. r V:. rr\\^ Acute Effects of (Bis) tributyltin ...AGENCY ACCESSION NO. DN888 749 11. TITLE (include SecuriyClassilicalion) ACUTE EFFECTS OF (BIS) TRIBUTYLTIN OXIDE ON MARINE ORGANISMS Summary of
Inhibition of nitrite-induced toxicity in channel catfish by calcium chloride and sodium chloride
Tommasso J.R., Wright; Simco, B.A.; Davis, K.B.
1980-01-01
Environmental chloride has been shown to inhibit methemoglobin formation in fish, thereby offering a protective effect against nitrite toxicity. Channel catfish (Ictalurus punctatus) were simultaneously exposed to various environmental nitrite and chloride levels (as either CaCl2 or NaCl) in dechlorinated tap water (40 mg/L total hardness, 47 mg/L alkalinity, 4 mg/L chloride, pH = 6.9-7.1, and temperature 21-24°C). Methemoglobin levels in fish simultaneously exposed to 2.5 mg/L nitrite and up to 30 mg/L chloride as either CaCl2 or NaCl were similar but significantly lower than in unprotected fish. Exposure to 10 mg/L nitrite and 60 mg/L chloride resulted in methemoglobin levels similar to those of the controls; most unprotected fish died. Fish exposed to 10 mg/L nitrite had significantly lower methemoglobin levels when protected with 15.0 mg/L chloride as CaCl2 than with NaCl. Fish exposed to nitrite in the presence of 60 mg/L chloride (as either CaCl2 or NaCl) had similar 24-h LC50 values that were significantly elevated above those obtained in the absence of chloride. Calcium had little effect on tolerance to nitrite toxicity in channel catfish in contrast to its large effect reported in steelhead trout (Salmo gairdneri).
Surface speciation and interactions between adsorbed chloride and water on cerium dioxide
NASA Astrophysics Data System (ADS)
Sutherland-Harper, Sophie; Taylor, Robin; Hobbs, Jeff; Pimblott, Simon; Pattrick, Richard; Sarsfield, Mark; Denecke, Melissa; Livens, Francis; Kaltsoyannis, Nikolas; Arey, Bruce; Kovarik, Libor; Engelhard, Mark; Waters, John; Pearce, Carolyn
2018-06-01
Ceria particles with different specific surface areas (SSA) were contaminated with chloride and water, then heat treated at 500 and 900 °C to investigate sorption behaviour of these species on metal oxides. Results from x-ray photoelectron spectroscopy and infrared spectroscopy showed chloride and water adsorption onto particles increased with surface area and that these species were mostly removed on heat treatment (from 6.3 to 0.8 at% Cl- on high SSA and from 1.4 to 0.4 at% on low SSA particles). X-ray diffraction revealed that chloride was not incorporated into the bulk ceria structure, but crystal size increased upon contamination. Ce LIII-edge x-ray absorption spectroscopy confirmed that chloride was not present in the first co-ordination sphere around Ce(IV) ions, so was not bonded to Ce as chloride in the bulk structure. Sintering of contaminated high SSA particles occurred with heat treatment at 900 °C, and they resembled low SSA particles synthesised at this temperature. Physical chloride-particle interactions were investigated using electron microscopy and energy dispersive x-ray analysis, showing that chloride was homogeneously distributed on ceria and that reduction of porosity did not trap surface-sorbed chloride inside the particles as surface area was reduced during sintering. This has implications for stabilisation of chloride-contaminated PuO2 for long term storage.
High Intracellular Chloride Slows the Decay of Glycinergic Currents
Pitt, Samantha J.; Sivilotti, Lucia G.; Beato, Marco
2009-01-01
The time course of currents mediated by native and recombinant glycine receptors was examined with a combination of rapid agonist applications to outside-out patches and single-channel recording. The deactivation time constant of currents evoked by brief, saturating pulses of glycine is profoundly affected by the chloride concentration on the intracellular side of the cell membrane. Deactivation was threefold slower when intracellular chloride was increased from a low level (10 mm), similar to that observed in living mature neurons, to 131 mm (“symmetrical” chloride, often used in pipette internal solutions). Single-channel analysis revealed that high chloride has its greatest effect on the channel closing rate, slowing it by a factor of 2 compared with the value we estimated in the cell-attached mode (in which the channels are at physiological intracellular chloride concentrations). The same effect of chloride was observed when glycinergic evoked synaptic currents were recorded from juvenile rat spinal motoneurons in vitro, because the decay time constant was reduced from ∼7ms to ∼3 ms when cells were dialyzed with 10 mm chloride intracellular recording solution. Our results indicate that the time course of glycinergic synaptic inhibition in intact neurons is much faster than is estimated by measurements in symmetrical chloride and can be modulated by changes in intracellular chloride concentration in the range that can occur in physiological or pathological conditions. PMID:18987182
Chloride concentrations in human hepatic cytosol and mitochondria are a function of age
Jahn, Stephan C.; Rowland-Faux, Laura; Stacpoole, Peter W.; James, Margaret O.
2015-01-01
We recently reported that, in a concentration-dependent manner, chloride protects hepatic glutathione transferase zeta 1 from inactivation by dichloroacetate, an investigational drug used in treating various acquired and congenital metabolic diseases. Despite the importance of chloride ions in normal physiology, and decades of study of chloride transport across membranes, the literature lacks information on chloride concentrations in animal tissues other than blood. In this study we measured chloride concentrations in human liver samples from male and female donors aged 1 day to 84 years (n = 97). Because glutathione transferase zeta 1 is present in cytosol and, to a lesser extent, in mitochondria, we measured chloride in these fractions by high-performance liquid chromatography analysis following conversion of the free chloride to pentafluorobenzylchloride. We found that chloride concentration decreased with age in hepatic cytosol but increased in liver mitochondria. In addition, chloride concentrations in cytosol, (105.2 ± 62.4 mM; range: 24.7 – 365.7 mM) were strikingly higher than those in mitochondria (4.2 ± 3.8 mM; range 0.9 – 22.2 mM). These results suggest a possible explanation for clinical observations seen in patients treated with dichloroacetate, whereby children metabolize the drug more rapidly than adults following repeated doses, and also provide information that may influence our understanding of normal liver physiology. PMID:25748576
Chloride concentrations in human hepatic cytosol and mitochondria are a function of age.
Jahn, Stephan C; Rowland-Faux, Laura; Stacpoole, Peter W; James, Margaret O
2015-04-10
We recently reported that, in a concentration-dependent manner, chloride protects hepatic glutathione transferase zeta 1 from inactivation by dichloroacetate, an investigational drug used in treating various acquired and congenital metabolic diseases. Despite the importance of chloride ions in normal physiology, and decades of study of chloride transport across membranes, the literature lacks information on chloride concentrations in animal tissues other than blood. In this study we measured chloride concentrations in human liver samples from male and female donors aged 1 day to 84 years (n = 97). Because glutathione transferase zeta 1 is present in cytosol and, to a lesser extent, in mitochondria, we measured chloride in these fractions by high-performance liquid chromatography analysis following conversion of the free chloride to pentafluorobenzylchloride. We found that chloride concentration decreased with age in hepatic cytosol but increased in liver mitochondria. In addition, chloride concentrations in cytosol, (105.2 ± 62.4 mM; range: 24.7-365.7 mM) were strikingly higher than those in mitochondria (4.2 ± 3.8 mM; range 0.9-22.2 mM). These results suggest a possible explanation for clinical observations seen in patients treated with dichloroacetate, whereby children metabolize the drug more rapidly than adults following repeated doses, and also provide information that may influence our understanding of normal liver physiology. Copyright © 2015 Elsevier Inc. All rights reserved.
Lindemann, J; Leiacker, R; Wiesmiller, K; Rettinger, G; Keck, T
2004-08-01
Benzalkonium chloride is a preservative commonly used in nasal decongestant sprays. It has been suggested that benzalkonium chloride may be harmful to the nasal mucosa. Decongestion with the vasoconstrictor xylometazoline containing benzalkonium chloride has been shown to cause a significant reduction of the nasal mucosal temperature. The purpose of the present study was to determine the short-term influence of xylometazoline nasal spray with and without benzalkonium chloride on the nasal mucosal temperature. Healthy volunteers (30) were included in the study. Fifteen volunteers received xylometazoline nasal spray (1.0 mg/mL) containing benzalkonium chloride (0.1 mg/mL) and 15 age-matched subjects, received xylometazoline nasal spray without benzalkonium chloride. Using a miniaturized thermocouple the septal mucosal temperature was continuously measured at defined intranasal detection sites before and after application of the nasal spray. The mucosal temperature values did not significantly differ between the group receiving xylometazoline containing benzalkonium chloride and the group receiving xylometazoline spray without benzalkonium chloride before and after decongestion (P > 0.05). In both study groups septal mucosal temperatures significantly decreased after decongestion (P < 0.05) because of a reduction of the nasal mucosal blood flow following vasoconstriction. This study indicates that benzalkonium chloride itself does not seem to influence nasal blood flow and nasal mucosal temperature in topical nasal decongestants.
George, Edward V.; Oster, Yale; Mundinger, David C.
1990-01-01
Deep UV projection lithography can be performed using an e-beam pumped solid excimer UV source, a mask, and a UV reduction camera. The UV source produces deep UV radiation in the range 1700-1300A using xenon, krypton or argon; shorter wavelengths of 850-650A can be obtained using neon or helium. A thin solid layer of the gas is formed on a cryogenically cooled plate and bombarded with an e-beam to cause fluorescence. The UV reduction camera utilizes multilayer mirrors having high reflectivity at the UV wavelength and images the mask onto a resist coated substrate at a preselected demagnification. The mask can be formed integrally with the source as an emitting mask.
Precision Penning Trap Mass Spectrometry of ^32S, ^84,86Kr and ^129,132Xe
NASA Astrophysics Data System (ADS)
Redshaw, Matthew
2005-05-01
Using a phase coherent technique to measure the cyclotron frequency of single ions in a Penning trap [1], we have performed mass measurements on ^32S and the two most abundant krypton and xenon isotopes ^84Kr, ^86Kr, ^ 129Xe and ^132Xe, to relative precisions of 0.1 ppb. This is a factor of ˜10-100 improvement in precision over current values [2]. [1] M.P. Bradley, J.V. Porto, S. Rainville, J.K. Thompson, and D.E. Pritchard, PRL 83, 4510 (1999). [2] G. Audi, A.H. Wapstra, and C. Thibault, Nucl Phys A729, 337 (2003).
X-ray microprobe of orbital alignment in strong-field ionized atoms.
Young, L; Arms, D A; Dufresne, E M; Dunford, R W; Ederer, D L; Höhr, C; Kanter, E P; Krässig, B; Landahl, E C; Peterson, E R; Rudati, J; Santra, R; Southworth, S H
2006-08-25
We have developed a synchrotron-based, time-resolved x-ray microprobe to investigate optical strong-field processes at intermediate intensities (10(14) - 10(15) W/cm2). This quantum-state specific probe has enabled the direct observation of orbital alignment in the residual ion produced by strong-field ionization of krypton atoms via resonant, polarized x-ray absorption. We found strong alignment to persist for a period long compared to the spin-orbit coupling time scale (6.2 fs). The observed degree of alignment can be explained by models that incorporate spin-orbit coupling. The methodology is applicable to a wide range of problems.
Experimental Evidence for Quantum Tunneling Time.
Camus, Nicolas; Yakaboylu, Enderalp; Fechner, Lutz; Klaiber, Michael; Laux, Martin; Mi, Yonghao; Hatsagortsyan, Karen Z; Pfeifer, Thomas; Keitel, Christoph H; Moshammer, Robert
2017-07-14
The first hundred attoseconds of the electron dynamics during strong field tunneling ionization are investigated. We quantify theoretically how the electron's classical trajectories in the continuum emerge from the tunneling process and test the results with those achieved in parallel from attoclock measurements. An especially high sensitivity on the tunneling barrier is accomplished here by comparing the momentum distributions of two atomic species of slightly deviating atomic potentials (argon and krypton) being ionized under absolutely identical conditions with near-infrared laser pulses (1300 nm). The agreement between experiment and theory provides clear evidence for a nonzero tunneling time delay and a nonvanishing longitudinal momentum of the electron at the "tunnel exit."
Experimental Evidence for Quantum Tunneling Time
NASA Astrophysics Data System (ADS)
Camus, Nicolas; Yakaboylu, Enderalp; Fechner, Lutz; Klaiber, Michael; Laux, Martin; Mi, Yonghao; Hatsagortsyan, Karen Z.; Pfeifer, Thomas; Keitel, Christoph H.; Moshammer, Robert
2017-07-01
The first hundred attoseconds of the electron dynamics during strong field tunneling ionization are investigated. We quantify theoretically how the electron's classical trajectories in the continuum emerge from the tunneling process and test the results with those achieved in parallel from attoclock measurements. An especially high sensitivity on the tunneling barrier is accomplished here by comparing the momentum distributions of two atomic species of slightly deviating atomic potentials (argon and krypton) being ionized under absolutely identical conditions with near-infrared laser pulses (1300 nm). The agreement between experiment and theory provides clear evidence for a nonzero tunneling time delay and a nonvanishing longitudinal momentum of the electron at the "tunnel exit."
Particle sizing in rocket motor studies utilizing hologram image processing
NASA Technical Reports Server (NTRS)
Netzer, David; Powers, John
1987-01-01
A technique of obtaining particle size information from holograms of combustion products is described. The holograms are obtained with a pulsed ruby laser through windows in a combustion chamber. The reconstruction is done with a krypton laser with the real image being viewed through a microscope. The particle size information is measured with a Quantimet 720 image processing system which can discriminate various features and perform measurements of the portions of interest in the image. Various problems that arise in the technique are discussed, especially those that are a consequence of the speckle due to the diffuse illumination used in the recording process.
Enthalpy of sublimation as measured using a silicon oscillator
NASA Astrophysics Data System (ADS)
Shakeel, Hamza; Pomeroy, J. M.
In this study, we report the enthalpy of sublimation of common gases (nitrogen, oxygen, argon, carbon dioxide, neon, krypton, xenon, and water vapor) using a large area silicon oscillator with a sub-ng (~0.027 ng/cm2) mass sensitivity. The double paddle oscillator design enables high frequency stability (17 ppb) at cryogenic temperatures and provides a consistent technique for enthalpy measurements. The enthalpies of sublimation are derived from the rate of mass loss during programmed thermal desorption and are detected as a change in the resonance frequency of the self-tracking oscillator. These measured enthalpy values show excellent agreement with the accepted literature values.
Hren, Janet
1983-01-01
Reaeration coefficients of the North Fork Licking River at Utica, Ohio were measured by the radioactive-tracer method. The tests were conducted on a 2.1-mile reach on September 23 and October 7, 1981, during low-flow conditions. Krypton-85 gas and tritium were the radioopactive tracers, which were used in conjunction with rhodamine-WT dye. The reaertion coefficients determined on September 23 were 3.09 days-1 (subreach 1-2) and 3.32 days-1 (subreach 2-3). On October 7, the values were 2.04 days -1 and 2.23 days-1 respectively.
Separation of rare gases and chiral molecules by selective binding in porous organic cages
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Linjiang; Reiss, Paul S.; Chong, Samantha Y.
2014-10-31
Abstract: The rare gases krypton, xenon, and radon pose both an economic opportunity and a potential environmental hazard. Xenon is used in commercial lighting, medical imaging, and anesthesia, and can sell for $5,000 per kilogram. Radon, by contrast, Is naturally radioactive and the second largest cause of lung cancer, and radioactive xenon, 133Xe, was a major pollutant released In the Fukushima Daiichi Nuclear Power Plant disaster. We describe an organic cage molecule that can capture xenon and radon with unprecedented selectivity, suggesting new technologies for environmental monitoring, removal of pollutants, or the recovery of rare, valuable elements from air.
Overtone, 2OH spectroscopy of H2Osbnd Kr
NASA Astrophysics Data System (ADS)
Vanfleteren, Thomas; Földes, Tomas; Rizopoulos, Athéna; Herman, Michel
2017-12-01
We have used continuous-wave cavity ring-down spectroscopy to record the spectrum of H2Osbnd Kr in the 2OH excitation range of H2O. 11 sub-bands have been observed for the main krypton isotope, 84 Kr. Their rotational structure (Trot = 18 K) is analyzed and the lines fitted together with literature microwave data, with a unitless standard deviation σ = 0.86 and 1.32 for ortho and para species, respectively. 4 more sub-bands are observed for the three other isotopes and are also analyzed. The upper state vibrational predissociation lifetime is estimated to 4 ns from observed spectral linewidths.
Development of an adsorption compressor for use in cryogenic refrigeration
NASA Technical Reports Server (NTRS)
Schember, Helen R.
1989-01-01
A new compressor with no moving parts has been developed which is able to supply a source of high-pressure gas to a Joule-Thompson based cryogenic refrigerator. The compressor relies on a newly implemented combination of high-surface-area Saran carbon (sorbent) and krypton gas (working fluid). In addition, an integral gas-gap heat switch is used to provide improved overall efficiency. A prototype compressor has been designed, built, and tested as a part of the Jet Propulsion Laboratory effort in sorption refrigeration. Performance data from the prototype unit described here demonstrate successful compressor performance and good agreement with theoretical predictions.
Time-resolved atomic inner-shell spectroscopy
NASA Astrophysics Data System (ADS)
Drescher, M.; Hentschel, M.; Kienberger, R.; Uiberacker, M.; Yakovlev, V.; Scrinzi, A.; Westerwalbesloh, Th.; Kleineberg, U.; Heinzmann, U.; Krausz, F.
2002-10-01
The characteristic time constants of the relaxation dynamics of core-excited atoms have hitherto been inferred from the linewidths of electronic transitions measured by continuous-wave extreme ultraviolet or X-ray spectroscopy. Here we demonstrate that a laser-based sampling system, consisting of a few-femtosecond visible light pulse and a synchronized sub-femtosecond soft X-ray pulse, allows us to trace these dynamics directly in the time domain with attosecond resolution. We have measured a lifetime of 7.9
NASA Astrophysics Data System (ADS)
Grum-Grzhimailo, A. N.; Gryzlova, E. V.; Kuzmina, E. I.; Chetverkina, A. S.; Strakhova, S. I.
2015-04-01
Two nonlinear atomic photoprocesses are theoretically considered with the emphasis on the photoelectron angular distributions and their modifications due to violation of the dipole approximation: sequential two-photon double ionization and two-color above threshold ionization. These reactions are now accessible with X-ray free electron lasers. Both processes are exemplified by the ionization of krypton: from the 4p shell in the sequential two-photon double ionization and from the 2s shell in the two-color above-threshold ionization, which are compared to the Ar(3p) and Ne(1s) ionization, respectively. Noticeable nondipole effects are predicted.
Specific surface area as a maturity index of lunar fines
NASA Technical Reports Server (NTRS)
Gammage, R. B.; Holmes, H. F.
1975-01-01
Mature surface fines have an equilibrium specific surface area of about 0.6 sq m/g the equivalent mean particle size being about 3 microns. The adsorption behavior of inert gases (reversible isotherms) indicates that the particles are also nonporous in the size range of pores from 10 to 3000 A. Apparently, in mature soils there is a balance in the forces which cause fining, attrition, pore filling, and growth of lunar dust grains. Immature, lightly irradiated soils usually have coarser grains which reduce in size as aging proceeds. The specific surface area, determined by nitrogen or krypton sorption at 77 K, is a valuable index of soil maturity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shuaibov, A K; Minya, A I; Hrytsak, R V
2015-02-28
We present the results of investigation of the characteristics of a nanosecond-barrier-discharge-pumped multiwave lamp based on a gas mixture of Ar – Kr – CCl{sub 4}, which emits in the spectral range of 170 – 260 nm. The main emission bands in the lamp spectrum are ArCl (B → X) near 175 nm, KrCl (B → X) near 222 nm and Cl{sub 2} (D' → A') near 258 nm. The lamp intensity with respect to pressure, working mixture composition and pump regime is optimised. (uv - vuv emitters)
Acceleration to high velocities and heating by impact using Nike KrF lasera)
NASA Astrophysics Data System (ADS)
Karasik, Max; Weaver, J. L.; Aglitskiy, Y.; Watari, T.; Arikawa, Y.; Sakaiya, T.; Oh, J.; Velikovich, A. L.; Zalesak, S. T.; Bates, J. W.; Obenschain, S. P.; Schmitt, A. J.; Murakami, M.; Azechi, H.
2010-05-01
The Nike krypton fluoride laser [S. P. Obenschain, S. E. Bodner, D. Colombant, et al., Phys. Plasmas 3, 2098 (1996)] is used to accelerate planar plastic foils to velocities that for the first time reach 1000 km/s. Collision of the highly accelerated deuterated polystyrene foil with a stationary target produces ˜Gbar shock pressures and results in heating of the foil to thermonuclear temperatures. The impact conditions are diagnosed using DD fusion neutron yield, with ˜106 neutrons produced during the collision. Time-of-flight neutron detectors are used to measure the ion temperature upon impact, which reaches 2-3 keV.
Some possibilities of using gas mixtures other than air in aerodynamic research
NASA Technical Reports Server (NTRS)
Chapman, Dean R
1956-01-01
A study is made of the advantages that can be realized in compressible-flow research by employing a substitute heavy gas in place of air. The present report is based on the idea that by properly mixing a heavy monatomic gas with a suitable heavy polyatomic gas, it is possible to obtain a heavy gas mixture which has the correct ratio of specific heats and which is nontoxic, nonflammable, thermally stable, chemically inert, and comprised of commercially available components. Calculations were made of wind-tunnel characteristics for 63 gas pairs comprising 21 different polyatomic gases properly mixed with each of three monatomic gases (argon, krypton, and zenon).
50 KW Class Krypton Hall Thruster Performance
NASA Technical Reports Server (NTRS)
Jacobson, David T.; Manzella, David H.
2003-01-01
The performance of a 50-kilowatt-class Hall thruster designed for operation on xenon propellant was measured using kryton propellant. The thruster was operated at discharge power levels ranging from 6.4 to 72.5 kilowatts. The device produced thrust ranging from 0.3 to 2.5 newtons. The thruster was operated at discharge voltages between 250 and 1000 volts. At the highest anode mass flow rate and discharge voltage and assuming a 100 percent singly charged condition, the discharge specific impulse approached the theoretical value. Discharge specific impulse of 4500 seconds was demonstrated at a discharge voltage of 1000 volts. The peak discharge efficiency was 64 percent at 650 volts.
Effect of copper chloride on the emissions of PCDD/Fs and PAHs from PVC combustion.
Wang, Dongli; Xu, Xiaobai; Zheng, Minghui; Chiu, Chung H
2002-09-01
The influences of temperature, air flow and the amount of copper chloride upon the types and amount of the toxic emissions such as polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) and polycyclic aromatic hydrocarbons (PAHs) during combustion of polyvinyl chloride (PVC) were investigated. The mechanism concerning the effect of temperature and copper chloride on the PCDD/Fs and PAHs formation was discussed. The results shown that without copper chloride, trace amounts of PCDD/Fs and large amounts of PAHs were found in the emissions from the pure PVC combustion under various combustion conditions. The addition of copper chloride enhanced PCDD/Fs formation, but it seems that the formation of PAHs decreased with increasing amount of copper chloride, and greater total amount of PAHs were produced at the higher temperature under our experimental conditions.
Rapid fixation of methylene chloride by a macrocyclic amine.
Lee, Jung-Jae; Stanger, Keith J; Noll, Bruce C; Gonzalez, Carlos; Marquez, Manuel; Smith, Bradley D
2005-03-30
A simple macrocyclic amine is alkylated by methylene chloride to give a quaternary ammonium chloride salt. When methylene chloride is the solvent, the reaction exhibits pseudo-first-order kinetics, and the reaction half-life at 25.0 degrees C is 2.0 min. The reaction half-life for a structurally related, acyclic amine is approximately 50 000 times longer. Detailed calculations favor a mechanism where the methylene chloride associates with the macrocycle to form an activated prereaction complex. The macrocyclic nitrogen subsequently attacks the methylene chloride with a classic SN2 trajectory, and although the carbon-chlorine bond breaks, the chloride leaving group does not separate from the newly formed cationic macrocycle, such that the product is a tightly associated ion-pair. X-ray crystal structures of the starting amine and the product salt, as well as kinetic data, support this mechanism.
Hamze, Benjamin; Vaillancourt, Régis; Sharp, Diane; Villarreal, Gilda
2016-01-01
The aim of this randomized single-blind study is to compare taste and odor disturbances in patients receiving 0.9% sodium chloride flushes from 2 brands. Seventy-five patients from 6 to 18 years of age received intravenous 0.9% sodium chloride infusions, and 50 healthy volunteers who tasted the 2 brands of 0.9% sodium chloride from prefilled syringes were assessed for taste and/or odor disturbances. Taste or odor disturbances were equally present in patients flushed with MedXL and Becton-Dickinson 0.9% sodium chloride. Disturbances are more frequent when 0.9% sodium chloride is flushed through central venous access devices than through peripheral catheters. No difference between the brands was found when healthy volunteers tasted it orally.
Pharmacological analysis of epithelial chloride secretion mechanisms in adult murine airways.
Gianotti, Ambra; Ferrera, Loretta; Philp, Amber R; Caci, Emanuela; Zegarra-Moran, Olga; Galietta, Luis J V; Flores, Carlos A
2016-06-15
Defective epithelial chloride secretion occurs in humans with cystic fibrosis (CF), a genetic defect due to loss of function of CFTR, a cAMP-activated chloride channel. In the airways, absence of an active CFTR causes a severe lung disease. In mice, genetic ablation of CFTR function does not result in similar lung pathology. This may be due to the expression of an alternative chloride channel which is activated by calcium. The most probable protein performing this function is TMEM16A, a calcium-activated chloride channel (CaCC). Our aim was to assess the relative contribution of CFTR and TMEM16A to chloride secretion in adult mouse trachea. For this purpose we tested pharmacological inhibitors of chloride channels in normal and CF mice. The amplitude of the cAMP-activated current was similar in both types of animals and was not affected by a selective CFTR inhibitor. In contrast, a CaCC inhibitor (CaCCinh-A01) strongly blocked the cAMP-activated current as well as the calcium-activated chloride secretion triggered by apical UTP. Although control experiments revealed that CaCCinh-A01 also shows inhibitory activity on CFTR, our results indicate that transepithelial chloride secretion in adult mouse trachea is independent of CFTR and that another channel, possibly TMEM16A, performs both cAMP- and calcium-activated chloride transport. The prevalent function of a non-CFTR channel may explain the absence of a defect in chloride transport in CF mice. Copyright © 2016. Published by Elsevier B.V.
Chloride Content of Fluids Used for Large-Volume Resuscitation Is Associated With Reduced Survival.
Sen, Ayan; Keener, Christopher M; Sileanu, Florentina E; Foldes, Emily; Clermont, Gilles; Murugan, Raghavan; Kellum, John A
2017-02-01
We sought to investigate if the chloride content of fluids used in resuscitation was associated with short- and long-term outcomes. We identified patients who received large-volume fluid resuscitation, defined as greater than 60 mL/kg over a 24-hour period. Chloride load was determined for each patient based on the chloride ion concentration of the fluids they received during large-volume fluid resuscitation multiplied by the volume of fluids. We compared the development of hyperchloremic acidosis, acute kidney injury, and survival among those with higher and lower chloride loads. University Medical Center. Patients admitted to ICUs from 2000 to 2008. None. Among 4,710 patients receiving large-volume fluid resuscitation, hyperchloremic acidosis was documented in 523 (11%). Crude rates of hyperchloremic acidosis, acute kidney injury, and hospital mortality all increased significantly as chloride load increased (p < 0.001). However, chloride load was no longer associated with hyperchloremic acidosis or acute kidney injury after controlling for total fluids, age, and baseline severity. Conversely, each 100 mEq increase in chloride load was associated with a 5.5% increase in the hazard of death even after controlling for total fluid volume, age, and severity (p = 0.0015) over 1 year. Chloride load is associated with significant adverse effects on survival out to 1 year even after controlling for total fluid load, age, and baseline severity of illness. However, the relationship between chloride load and development of hyperchloremic acidosis or acute kidney injury is less clear, and further research is needed to elucidate the mechanisms underlying the adverse effects of chloride load on survival.
Chloride: the queen of electrolytes?
Berend, Kenrick; van Hulsteijn, Leonard Hendrik; Gans, Rijk O B
2012-04-01
Channelopathies, defined as diseases that are caused by mutations in genes encoding ion channels, are associated with a wide variety of symptoms and have been documented extensively over the past decade. In contrast, despite the important role of chloride in serum, textbooks in general do not allocate chapters exclusively on hypochloremia or hyperchloremia and information on chloride other than channelopathies is scattered in the literature. To systematically review the function of chloride in man, data for this review include searches of MEDLINE, PubMed, and references from relevant articles including the search terms "chloride," "HCl," "chloride channel" "acid-base," "acidosis," "alkalosis," "anion gap" "strong anion gap" "Stewart," "base excess" and "lactate." In addition, internal medicine, critical care, nephrology and gastroenterology textbooks were evaluated on topics pertaining the assessment and management of acid-base disorders, including reference lists from journals or textbooks. Chloride is, after sodium, the most abundant electrolyte in serum, with a key role in the regulation of body fluids, electrolyte balance, the preservation of electrical neutrality, acid-base status and it is an essential component for the assessment of many pathological conditions. When assessing serum electrolytes, abnormal chloride levels alone usually signify a more serious underlying metabolic disorder, such as metabolic acidosis or alkalosis. Chloride is an important component of diagnostic tests in a wide array of clinical situations. In these cases, chloride can be tested in sweat, serum, urine and feces. Abnormalities in chloride channel expression and function in many organs can cause a range of disorders. Copyright © 2011 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.
40 CFR 433.11 - Specialized definitions.
Code of Federal Regulations, 2013 CFR
2013-07-01
...-chloroisopropyl) ether Bis (2-chloroethoxy) methane Methylene chloride (dichloromethane) Methyl chloride...-phenlene pyrene) Pyrene Tetrachloroethylene Toluene Trichloroethylene Vinyl chloride (chloroethylene...
Fermentation of cucumbers brined with calcium chloride instead of sodium chloride
USDA-ARS?s Scientific Manuscript database
Generation of waste water containing sodium chloride from cucumber fermentation tank yards could be eliminated if cucumbers were fermented in brines that did not contain this salt. To determine if this is feasible, cucumbers were fermented in brines that contained only calcium chloride to maintain f...
21 CFR 582.1193 - Calcium chloride.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Calcium chloride. 582.1193 Section 582.1193 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Additives § 582.1193 Calcium chloride. (a) Product. Calcium chloride. (b) Conditions of use. This substance...
21 CFR 172.330 - Calcium pantothenate, calcium chloride double salt.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Calcium pantothenate, calcium chloride double salt... FOOD FOR HUMAN CONSUMPTION Special Dietary and Nutritional Additives § 172.330 Calcium pantothenate, calcium chloride double salt. The food additive calcium chloride double salt of calcium pantothenate may...
21 CFR 173.255 - Methylene chloride.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Methylene chloride. 173.255 Section 173.255 Food... Solvents, Lubricants, Release Agents and Related Substances § 173.255 Methylene chloride. Methylene chloride may be present in food under the following conditions: (a) In spice oleoresins as a residue from...
21 CFR 173.255 - Methylene chloride.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Methylene chloride. 173.255 Section 173.255 Food... Solvents, Lubricants, Release Agents and Related Substances § 173.255 Methylene chloride. Methylene chloride may be present in food under the following conditions: (a) In spice oleoresins as a residue from...
40 CFR Table 7 to Subpart Vvvvvv... - Partially Soluble HAP
Code of Federal Regulations, 2013 CFR
2013-07-01
.... Methylene chloride 75092 43. N-hexane 110543 44. N,N-dimethylaniline 121697 45. Naphthalene 91203 46...-Dichloroethylene (vinylidene chloride) 75354 5. 1,2-Dibromoethane 106934 6. 1,2-Dichloroethane (ethylene dichloride.... Acrolein 107028 15. Acrylonitrile 107131 16. Allyl chloride 107051 17. Benzene 71432 18. Benzyl chloride...
40 CFR Table 7 to Subpart Vvvvvv... - Partially Soluble HAP
Code of Federal Regulations, 2014 CFR
2014-07-01
.... Methylene chloride 75092 43. N-hexane 110543 44. N,N-dimethylaniline 121697 45. Naphthalene 91203 46...-Dichloroethylene (vinylidene chloride) 75354 5. 1,2-Dibromoethane 106934 6. 1,2-Dichloroethane (ethylene dichloride.... Acrolein 107028 15. Acrylonitrile 107131 16. Allyl chloride 107051 17. Benzene 71432 18. Benzyl chloride...
40 CFR Table 7 to Subpart Vvvvvv... - Partially Soluble HAP
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Methylene chloride 75092 43. N-hexane 110543 44. N,N-dimethylaniline 121697 45. Naphthalene 91203 46...-Dichloroethylene (vinylidene chloride) 75354 5. 1,2-Dibromoethane 106934 6. 1,2-Dichloroethane (ethylene dichloride.... Acrolein 107028 15. Acrylonitrile 107131 16. Allyl chloride 107051 17. Benzene 71432 18. Benzyl chloride...
Commercial scale cucumber fermentations brined with calcium chloride instead of sodium chloride
USDA-ARS?s Scientific Manuscript database
Development of low salt cucumber fermentation processes present opportunities to reduce the amount of sodium chloride (NaCl) that reaches fresh water streams from industrial activities. The objective of this research was to translate cucumber fermentation brined with calcium chloride instead of NaCl...
46 CFR 154.1750 - Butadiene or vinyl chloride: Refrigeration system.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 5 2014-10-01 2014-10-01 false Butadiene or vinyl chloride: Refrigeration system. 154... and Operating Requirements § 154.1750 Butadiene or vinyl chloride: Refrigeration system. A refrigeration system for butadiene or vinyl chloride must not use vapor compression unless it: (a) Avoids any...
46 CFR 154.1750 - Butadiene or vinyl chloride: Refrigeration system.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Butadiene or vinyl chloride: Refrigeration system. 154... and Operating Requirements § 154.1750 Butadiene or vinyl chloride: Refrigeration system. A refrigeration system for butadiene or vinyl chloride must not use vapor compression unless it: (a) Avoids any...
46 CFR 154.1750 - Butadiene or vinyl chloride: Refrigeration system.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 5 2013-10-01 2013-10-01 false Butadiene or vinyl chloride: Refrigeration system. 154... and Operating Requirements § 154.1750 Butadiene or vinyl chloride: Refrigeration system. A refrigeration system for butadiene or vinyl chloride must not use vapor compression unless it: (a) Avoids any...
46 CFR 154.1750 - Butadiene or vinyl chloride: Refrigeration system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Butadiene or vinyl chloride: Refrigeration system. 154... and Operating Requirements § 154.1750 Butadiene or vinyl chloride: Refrigeration system. A refrigeration system for butadiene or vinyl chloride must not use vapor compression unless it: (a) Avoids any...
46 CFR 154.1750 - Butadiene or vinyl chloride: Refrigeration system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Butadiene or vinyl chloride: Refrigeration system. 154... and Operating Requirements § 154.1750 Butadiene or vinyl chloride: Refrigeration system. A refrigeration system for butadiene or vinyl chloride must not use vapor compression unless it: (a) Avoids any...
21 CFR 182.8985 - Zinc chloride.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Zinc chloride. 182.8985 Section 182.8985 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) SUBSTANCES GENERALLY RECOGNIZED AS SAFE Nutrients § 182.8985 Zinc chloride. (a) Product. Zinc chloride. (b) Conditions...
21 CFR 582.5985 - Zinc chloride.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Zinc chloride. 582.5985 Section 582.5985 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS... 1 § 582.5985 Zinc chloride. (a) Product. Zinc chloride. (b) Conditions of use. This substance is...
21 CFR 182.8985 - Zinc chloride.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Zinc chloride. 182.8985 Section 182.8985 Food and... CONSUMPTION (CONTINUED) SUBSTANCES GENERALLY RECOGNIZED AS SAFE Nutrients § 182.8985 Zinc chloride. (a) Product. Zinc chloride. (b) Conditions of use. This substance is generally recognized as safe when used in...
Code of Federal Regulations, 2010 CFR
2010-07-01
... alkyldimethyl, chlorides, reaction products with silica. 721.10154 Section 721.10154 Protection of Environment..., dicoco alkyldimethyl, chlorides, reaction products with silica. (a) Chemical substance and significant..., dicoco alkyldimethyl, chlorides, reaction products with silica (PMN P-08-157; CAS No. 956147-76-5) is...
Code of Federal Regulations, 2011 CFR
2011-07-01
... alkyldimethyl, chlorides, reaction products with silica. 721.10154 Section 721.10154 Protection of Environment..., dicoco alkyldimethyl, chlorides, reaction products with silica. (a) Chemical substance and significant..., dicoco alkyldimethyl, chlorides, reaction products with silica (PMN P-08-157; CAS No. 956147-76-5) is...
21 CFR 582.5985 - Zinc chloride.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Zinc chloride. 582.5985 Section 582.5985 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS... 1 § 582.5985 Zinc chloride. (a) Product. Zinc chloride. (b) Conditions of use. This substance is...
21 CFR 182.8985 - Zinc chloride.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Zinc chloride. 182.8985 Section 182.8985 Food and... CONSUMPTION (CONTINUED) SUBSTANCES GENERALLY RECOGNIZED AS SAFE Nutrients § 182.8985 Zinc chloride. (a) Product. Zinc chloride. (b) Conditions of use. This substance is generally recognized as safe when used in...
21 CFR 172.180 - Stannous chloride.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Stannous chloride. 172.180 Section 172.180 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN... Preservatives § 172.180 Stannous chloride. The food additive stannous chloride may be safely used for color...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-19
... National Emission Standards for Hazardous Air Pollutants for Polyvinyl Chloride and Copolymers Production... Polyvinyl Chloride and Copolymers Production is being extended for 14 days. DATES: Comments. The public... for the May 20, 2011, Proposed Polyvinyl Chloride and Copolymers Production Rule, the EPA is extending...
40 CFR 721.6167 - Piperdinium, 1,1-dimethyl-, chloride.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Piperdinium, 1,1-dimethyl-, chloride... Substances § 721.6167 Piperdinium, 1,1-dimethyl-, chloride. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as piperdinium, 1,1-dimethyl-, chloride. (PMN...
Code of Federal Regulations, 2010 CFR
2010-10-01
... methyl bromide or methyl chloride mixtures, etc. 173.193 Section 173.193 Transportation Other Regulations... bromide, chloropicrin and methyl bromide or methyl chloride mixtures, etc. (a) Bromoacetone must be...) Bromoacetone, methyl bromide, chloropicrin and methyl bromide mixtures, chloropicrin and methyl chloride...
21 CFR 182.8252 - Choline chloride.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Choline chloride. 182.8252 Section 182.8252 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR... chloride. (a) Product. Choline chloride. (b) Conditions of use. This substance is generally recognized as...
21 CFR 520.310 - Caramiphen ethanedisulfonate and ammonium chloride tablets.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Caramiphen ethanedisulfonate and ammonium chloride... § 520.310 Caramiphen ethanedisulfonate and ammonium chloride tablets. (a) Specifications. Each tablet contains 10 milligrams of 5st caramiphen ethanedisulfonate and 80 milligrams of ammonium chloride.1 1 These...
REMOVAL OF CHLORIDE FROM AQUEOUS SOLUTIONS
Schulz, W.W.
1959-08-01
The removal of chlorides from aqueons solutions is described. The process involves contacting the aqueous chloride containing solution with a benzene solution about 0.005 M in phenyl mercuric acetate whereby the chloride anions are taken up by the organic phase and separating the organic phase from the aqueous solutions.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-17
... determined that Halflytely and Bisacodyl Tablets Bowel Prep Kit (polyethylene glycol (PEG) 3350, sodium chloride, sodium bicarbonate, and potassium chloride for oral solution and two bisacodyl delayed release... kits containing PEG-3350, sodium chloride, sodium bicarbonate, and potassium chloride for oral solution...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-19
... determined that HALFLYTELY AND BISACODYL TABLETS BOWEL PREP KIT (polyethylene glycol (PEG) 3350, sodium chloride, sodium bicarbonate, and potassium chloride for oral solution and 4 bisacodyl delayed release... kits containing PEG-3350, sodium chloride, sodium bicarbonate, and potassium chloride for oral solution...
Fabrication Of Metal Chloride Cathodes By Sintering
NASA Technical Reports Server (NTRS)
Bugga, Ratnakumar V.; Di Stefano, Salvador; Bankston, C. Perry
1992-01-01
Transition-metal chloride cathodes for use in high-temperature rechargeable sodium batteries prepared by sintering transition-metal powders mixed with sodium chloride. Need for difficult and dangerous chlorination process eliminated. Proportions of transition metal and sodium chloride in mixture adjusted to suit specific requirements. Cathodes integral to sodium/metal-chloride batteries, which have advantages over sodium/sulfur batteries including energy densities, increased safety, reduced material and thermal-management problems, and ease of operation and assembly. Being evaluated for supplying electrical power during peak demand and electric vehicles.
Calcination process for radioactive wastes
Kilian, Douglas C.
1976-05-04
The present invention provides a method for minimizing the volatilization of chlorides during solidification in a fluidized-bed calciner of liquids containing sodium, nitrate and chloride ions. Zirconium and fluoride are introduced into the liquid, and one-half mole of calcium nitrate is added per mole of fluoride present in the liquid mixture. The mixture is calcined in the fluidized-bed calciner at about 500.degree.C., producing a high bulk density calcine product containing the chloride, thus tying up the chloride in the solid product and minimizing chloride volatilization.
Anaerobic mineralization of vinyl chloride in Fe(III)-reducing, aquifer sediments
Bradley, P.M.; Chapelle, F.H.
1996-01-01
Within anaerobic aquifer systems, reductive dehalogenation of polychlorinated ethenes commonly results in the accumulation of vinyl chloride, which is highly toxic and carcinogenic to humans. Anaerobic reduction of vinyl chloride is considered to be slow and incomplete. Here, we provide the first evidence for anaerobic oxidation of vinyl chloride under Fe(III)reducing conditions. Addition of chelated Fe(III) (as Fe-EDTA) to anaerobic aquifer microcosms resulted in mineralization of up to 34% of [1,2- 14C]vinyl chloride within 84 h. The results indicate that vinyl chloride can be mineralized under anaerobic, Fe(III)-reducing conditions and that the bioavailability of Fe(III) is an important factor affecting the rates of mineralization.
Antidepressants and seizure-interactions at the GABA-receptor chloride-ionophore complex
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malatynska, E.; Knapp, R.J.; Ikeda, M.
1988-01-01
Convulsive seizures are a potential side effect of antidepressant drug treatment and can be produced by all classes of antidepressants. It is also know that some convulsant and anticonvulsant drug actions are mediated by the GABA-receptor chloride-ionophore complex. Drugs acting at this complex appear to induce convulsions by inhibiting chloride conductance through the associated chloride channel. Using the method of GABA-stimulated /sup 36/Cl-uptake by rat cerebral cortical vesicles, we show that some antidepressant drugs can inhibit the GABA-receptor chloride uptake, and that the degree of chloride channel inhibition by these drugs correlates with the frequency of convulsive seizures induced bymore » them.« less
Apparatus and method for making metal chloride salt product
Miller, William E [Naperville, IL; Tomczuk, Zygmunt [Homer Glen, IL; Richmann, Michael K [Carlsbad, NM
2007-05-15
A method of producing metal chlorides is disclosed in which chlorine gas is introduced into liquid Cd. CdCl.sub.2 salt is floating on the liquid Cd and as more liquid CdCl.sub.2 is formed it separates from the liquid Cd metal and dissolves in the salt. The salt with the CdCl.sub.2 dissolved therein contacts a metal which reacts with CdCl.sub.2 to form a metal chloride, forming a mixture of metal chloride and CdCl.sub.2. After separation of bulk Cd from the salt, by gravitational means, the metal chloride is obtained by distillation which removes CdCl.sub.2 and any Cd dissolved in the metal chloride.
Role of metal oxides in the thermal degradation of poly(vinyl chloride)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gupta, M.C.; Viswanath, S.G.
Thermal degradation of poly(vinyl chloride) has been studied in the presence of metal oxides by a thermogravimetric method. It follows a two-step mechanism. In the first step chlorine free radical is formed as in the case of pure PVC, and in the second step chlorine free radical replaces oxygen from metal oxide to form metal chloride and oxygen free radical. Subsequently, the oxygen free radical abstracts hydrogen from PVC. Formation of metal chloride is the rate-controlling step. The metal chlorides formed during the thermal degradation either volatilize or decompose simultaneously to lower metallic chlorides depending on the boiling point ormore » the volatilization temperature.« less
[Sodium chloride 0.9%: nephrotoxic crystalloid?].
Dombre, Vincent; De Seigneux, Sophie; Schiffer, Eduardo
2016-02-03
Sodium chloride 0.9%, often incorrectly called physiological saline, contains higher concentration of chloride compared to plasma. It is known that the administration of sodium chloride 0.9% can cause hyperchloremic metabolic acidosis in a reproducible manner. The elevated chloride concentration in 0.9% NaCl solution can also adversely affect renal perfusion. This effect is thought to be induced by hyperchloremia that causes renal artery vasoconstriction. For these reasons, the use of 0.9% NaCl solution is raising attention and some would advocate the use of a more "physiological" solution, such as balanced solutions that contain a level of chloride closer to that of plasma. Few prospective, randomized, controlled trials are available today and most were done in a perioperative setting. Some studies suggest that the chloride excess in 0.9% NaCl solution could have clinical consequences; however, this remains to be established by quality randomized controlled trials.
NASA Astrophysics Data System (ADS)
Lei, Mingfeng; Lin, Dayong; Liu, Jianwen; Shi, Chenghua; Ma, Jianjun; Yang, Weichao; Yu, Xiaoniu
2018-03-01
For the purpose of investigating lining concrete durability, this study derives a modified chloride diffusion model for concrete based on the odd continuation of boundary conditions and Fourier transform. In order to achieve this, the linear stress distribution on a sectional structure is considered, detailed procedures and methods are presented for model verification and parametric analysis. Simulation results show that the chloride diffusion model can reflect the effects of linear stress distribution of the sectional structure on the chloride diffusivity with reliable accuracy. Along with the natural environmental characteristics of practical engineering structures, reference value ranges of model parameters are provided. Furthermore, a chloride diffusion model is extended for the consideration of multi-factor coupling of linear stress distribution, chloride concentration and diffusion time. Comparison between model simulation and typical current research results shows that the presented model can produce better considerations with a greater universality.
Buried chloride stereochemistry in the Protein Data Bank
2014-01-01
Background Despite the chloride anion is involved in fundamental biological processes, its interactions with proteins are little known. In particular, we lack a systematic survey of its coordination spheres. Results The analysis of a non-redundant set (pairwise sequence identity?30%) of 1739 high resolution (<2 Å) crystal structures that contain at least one chloride anion shows that the first coordination spheres of the chlorides are essentially constituted by hydrogen bond donors. Amongst the side-chains positively charged, arginine interacts with chlorides much more frequently than lysine. Although the most common coordination number is 4, the coordination stereochemistry is closer to the expected geometry when the coordination number is 5, suggesting that this is the coordination number towards which the chlorides tend when they interact with proteins. Conclusions The results of these analyses are useful in interpreting, describing, and validating new protein crystal structures that contain chloride anions. PMID:25928393
Buried chloride stereochemistry in the Protein Data Bank.
Carugo, Oliviero
2014-09-23
Despite the chloride anion is involved in fundamental biological processes, its interactions with proteins are little known. In particular, we lack a systematic survey of its coordination spheres. The analysis of a non-redundant set (pairwise sequence identity < 30%) of 1739 high resolution (<2 Å) crystal structures that contain at least one chloride anion shows that the first coordination spheres of the chlorides are essentially constituted by hydrogen bond donors. Amongst the side-chains positively charged, arginine interacts with chlorides much more frequently than lysine. Although the most common coordination number is 4, the coordination stereochemistry is closer to the expected geometry when the coordination number is 5, suggesting that this is the coordination number towards which the chlorides tend when they interact with proteins. The results of these analyses are useful in interpreting, describing, and validating new protein crystal structures that contain chloride anions.
21 CFR 184.1426 - Magnesium chloride.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Magnesium chloride. 184.1426 Section 184.1426 Food... Specific Substances Affirmed as GRAS § 184.1426 Magnesium chloride. (a) Magnesium chloride (MgC12·6H2O, CAS... mineral bischofite. It is prepared by dissolving magnesium oxide, hydroxide, or carbonate in aqueous...
21 CFR 184.1426 - Magnesium chloride.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Magnesium chloride. 184.1426 Section 184.1426 Food... Specific Substances Affirmed as GRAS § 184.1426 Magnesium chloride. (a) Magnesium chloride (MgC12·6H2O, CAS... mineral bischofite. It is prepared by dissolving magnesium oxide, hydroxide, or carbonate in aqueous...
Production of aluminum metal by electrolysis of aluminum sulfide
Minh, N.Q.; Loutfy, R.O.; Yao, N.P.
1982-04-01
Metallic aluminum may be produced by the electrolysis of Al/sub 2/S/sub 3/ at 700 to 800/sup 0/C in a chloride melt composed of one or more alkali metal chlorides, and one or more alkaline earth metal chlorides and/or aluminum chloride to provide improved operating characteristics of the process.
Production of aluminum metal by electrolysis of aluminum sulfide
Minh, Nguyen Q.; Loutfy, Raouf O.; Yao, Neng-Ping
1984-01-01
Production of metallic aluminum by the electrolysis of Al.sub.2 S.sub.3 at 700.degree.-800.degree. C. in a chloride melt composed of one or more alkali metal chlorides, and one or more alkaline earth metal chlorides and/or aluminum chloride to provide improved operating characteristics of the process.
Making Positive Electrodes For Sodium/Metal Chloride Cells
NASA Technical Reports Server (NTRS)
Bugga, Ratnakumar V.; Distefano, Salvador; Bankston, C. Perry
1992-01-01
High coulombic yields provided by sodium/metal chloride battery in which cathode formed by impregnating sintered nickel plaque with saturated solution of nickel chloride. Charge/discharge cycling of nickel chloride electrode results in very little loss of capacity. Used in spacecraft, electric land vehicles, and other applications in which high-energy-density power systems required.
21 CFR 184.1446 - Manganese chloride.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Manganese chloride. 184.1446 Section 184.1446 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR... Specific Substances Affirmed as GRAS § 184.1446 Manganese chloride. (a) Manganese chloride (MnCl2·4H2O, CAS...
21 CFR 177.1960 - Vinyl chloride-hexene-1 copolymers.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Vinyl chloride-hexene-1 copolymers. 177.1960... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1960 Vinyl chloride-hexene-1 copolymers. The vinyl chloride-hexene-1 copolymers identified in paragraph (a) of this section or as...
46 CFR 154.1740 - Vinyl chloride: Inhibiting and inerting.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Vinyl chloride: Inhibiting and inerting. 154.1740... Operating Requirements § 154.1740 Vinyl chloride: Inhibiting and inerting. When a vessel is carrying vinyl chloride, the master shall ensure that: (a) Section 154.1818 is met; or (b) Section 154.1710 is met, and...
21 CFR 184.1426 - Magnesium chloride.
Code of Federal Regulations, 2011 CFR
2011-04-01
... mineral bischofite. It is prepared by dissolving magnesium oxide, hydroxide, or carbonate in aqueous... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Magnesium chloride. 184.1426 Section 184.1426 Food... Specific Substances Affirmed as GRAS § 184.1426 Magnesium chloride. (a) Magnesium chloride (MgC12·6H2O, CAS...
21 CFR 184.1426 - Magnesium chloride.
Code of Federal Regulations, 2010 CFR
2010-04-01
... mineral bischofite. It is prepared by dissolving magnesium oxide, hydroxide, or carbonate in aqueous... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Magnesium chloride. 184.1426 Section 184.1426 Food... Specific Substances Affirmed as GRAS § 184.1426 Magnesium chloride. (a) Magnesium chloride (MgC12·6H2O, CAS...
21 CFR 520.260 - n-Butyl chloride capsules.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 6 2010-04-01 2010-04-01 false n-Butyl chloride capsules. 520.260 Section 520.260... DRUGS, FEEDS, AND RELATED PRODUCTS ORAL DOSAGE FORM NEW ANIMAL DRUGS § 520.260 n-Butyl chloride capsules. (a)(1) Specifications. n-Butyl chloride capsules, veterinary contain 272 milligrams or 816 milligrams...
de Souza, Vanessa Rios; Freire, Tassyana Vieira Marques; Saraiva, Carla Gonçalves; de Deus Souza Carneiro, João; Pinheiro, Ana Carla Marques; Nunes, Cleiton Antônio
2013-08-01
Studies indicate a positive association between dietary salt intake and some diseases, which has promoted the tendency to reduce the sodium in foods. The objective of this study was to determine the equivalent amount of different sodium chloride replacements required to promote the same degree of ideal saltiness in butter and to study the sensory profile of sodium chloride and the substitutes using the analysis of Temporal Dominance of Sensations (TDS). Using the magnitude estimation method, it was determined that the potencies of potassium chloride, monosodium glutamate and potassium phosphate relative to the 1% sodium chloride in butter are 83·33, 31·59 and 33·32, respectively. Regarding the sensory profile of the tested salt substitutes, a bitter taste was perceived in the butter with potassium chloride, a sour taste was perceived in the butter with potassium phosphate and sweet and umami tastes were dominant in the butter with monosodium glutamate. Of all the salt substitutes tested calcium lactate, potassium lactate, calcium chloride and magnesium chloride were impractical to use in butter.
Plutonium recovery from spent reactor fuel by uranium displacement
Ackerman, John P.
1992-01-01
A process for separating uranium values and transuranic values from fission products containing rare earth values when the values are contained together in a molten chloride salt electrolyte. A molten chloride salt electrolyte with a first ratio of plutonium chloride to uranium chloride is contacted with both a solid cathode and an anode having values of uranium and fission products including plutonium. A voltage is applied across the anode and cathode electrolytically to transfer uranium and plutonium from the anode to the electrolyte while uranium values in the electrolyte electrolytically deposit as uranium metal on the solid cathode in an amount equal to the uranium and plutonium transferred from the anode causing the electrolyte to have a second ratio of plutonium chloride to uranium chloride. Then the solid cathode with the uranium metal deposited thereon is removed and molten cadmium having uranium dissolved therein is brought into contact with the electrolyte resulting in chemical transfer of plutonium values from the electrolyte to the molten cadmium and transfer of uranium values from the molten cadmium to the electrolyte until the first ratio of plutonium chloride to uranium chloride is reestablished.