Sample records for kurz titanium prosthesis

  1. Long-term hearing result using Kurz titanium ossicular implants.

    PubMed

    Hess-Erga, Jeanette; Møller, Per; Vassbotn, Flemming Slinning

    2013-05-01

    Titanium implants in middle ear surgery were introduced in the late 90s and are now frequently used in middle ear surgery. However, long-term studies of patient outcome are few and have only been published in subgroups of patients. We report the long-term effect of titanium middle ear implants for ossicular reconstruction in chronic ear disease investigated in a Norwegian tertiary otological referral centre. Retrospective chart reviews were performed for procedures involving 76 titanium implants between 2000 and 2007. All patients who underwent surgery using the Kurz Vario titanium implant were included in the study. Audiological parameters using four frequencies, 0.5, 1, 2, and 3 kHz, according to AAO-HNS guidelines, was assessed pre and postoperatively. Otosurgical procedures, complications, revisions, and extrusion rates were analyzed. The study had no dropouts. The partial ossicular replacement prosthesis (PORP) was used in 44 procedures and the total ossicular replacement prosthesis (TORP) in 32 procedures, respectively. Mean follow-up was 5.2 years (62 months). The ossiculoplasties were performed as staging procedures or in combination with other chronic ear surgery. The same surgeon performed all the procedures. A postoperative air-bone gap of ≤ 20 dB was obtained in 74 % of the patients, 82 % for the Bell (PORP) prosthesis, and 63 % for the Arial (TORP) prosthesis. The extrusion rate was 5 %. We conclude that titanium ossicular implants give stable and excellent long-term hearing results.

  2. Short-term results using Kurz titanium ossicular implants.

    PubMed

    Vassbotn, Flemming S; Møller, Per; Silvola, Juha

    2007-01-01

    The efficiency of titanium middle ear prosthesis for ossicular reconstruction in chronic ear disease is investigated in a Scandinavian two-center retrospective study from a Norwegian tertiary otology referral center and a Finnish otology referral center. Retrospective chart reviews were performed for procedures involving 73 titanium prostheses between 1999 and 2004. All patients that underwent surgery including the Kurz Vario titanium prosthesis were included in the study, 38 procedures including the partial ossicular replacement prosthesis (PORP) and 35 procedures including the total ossicular replacement prosthesis (TORP). Mean follow-up was 14 months. The ossiculoplasty was performed alone (29 patients) or in combination with other chronic ear surgery procedures (34 patients). Comparisons of preoperative and postoperative pure tone averages (0.5, 1, 2, and 3 kHz) according to AAO-HNS guidelines are presented, as well as data for different PTA definitions. Otosurgery procedures, complications, revisions, and extrusion rates are reported. A postoperative air-bone gap (ABG) of

  3. [Lysis of the incus long process and incudostapedial rebridging ossiculoplasty: comparative study of titanium-gold angle prosthesis Plester-type versus Martin Incudo prosthesis hydroxylapatite].

    PubMed

    Faye, M B; Martin, C; Schmerber, S

    2013-01-01

    We report two surgical techniques devised to restore a disrupted incudostapedial joint. Thirty patients underwent rebridging of distal portion of incus long process in the ENT Department of University of Grenoble and Saint-Etienne, between October 1998 and September 2002. Two types of ossicular prostheses were used: A titanium-gold angle prosthesis according to Plester Winkel Kurz (n = 16 patients), and a hydroxylapatite prosthesis as Martin Incudo Prosthesis (n = 14 patients). The average hearing gain in short term is of 8.30 dB for the Martin-Incudo group. It is of 5.23 dB in the Winkel group. Seven and three cases of failures (Residual Rinne > 20 dB) were noticed respectively in the groups Martin-Incudo and Winkel. Seven and four cases of labyrinthisation were observed respectively in the groups Martin-Incudo and Winkel. The average hearing gain in long term is 3.43 dB in the Martin-Incudo group; and 2.85 dB among patients with Winkel Kurz prosthesis. Average residual Rinne is higher than 20 dB in the Winkel group. The hearing gain is not statistically significant between the two groups (p > 0.05). The titanium partial prosthesis did not give good functional results. In the case of a limited lysis (< 2 mm) of the distal portion of incus, we use the cement or cartilage interposition. When ossicular chain cannot be preserved entirely, we privilege incus transposition or a titanium PORP. The Martin-Incudo prosthesis seems interesting in the event of lysis of 2 mm of the long process of incus, nevertheless engineering changes are necessary in order to make rigid the incudostapedial joint.

  4. Audiological comparison between two different clips prostheses in stapes surgery.

    PubMed

    Potena, M; Portmann, D; Guindi, S

    2015-01-01

    To compare audiometric results and complications of stapes surgery with two different types of piston prosthesis, the Portmann Clip Piston (Medtronic) (PCP) and the Soft Clip Piston (Kurz) (SCP). Study conducted on 64 patients who underwent primary stapedotomy from 2008 to 2011. We matched for each case of stapedotomy with the PCP (Medtronic Xomed Inc. Portmann Clip Piston Stainless Steel/Fluoroplastic) a case with the SCP (Heinz Kurz GmbH Medizintechnik Soft Piston Clip Titanium). Each group consisted of 32 patients, and patients in both groups were matched with respect to gender, age, bilateral or unilateral otosclerosis, otological symptoms (tinnitus, vertigo or dizziness), family history, operated side and the Portmann grading for otosclerosis. The length of the prosthesis used was reported. Post-operative complications such as tinnitus, vertigo, hearing loss and altered taste were documented. Each patient was subjected to a preoperative and postoperative audiogram (follow-up at the second month after the surgery). We used the Student test for statistical analysis. Statistical significance was set at < 0.01. None of the patients experienced a post-operative hearing loss and none required a later revision surgery. No statistically significant difference was found between the two populations regarding demographic data (age, sex, side, bilaterality, family history, stage and lenght of piston) and hearing level (> 0.01) in the air, bone conduction and air-bone gap (ABG). Postoperative complications did not result to be significantly different between the two groups. Also, both groups showed a significant improvement (< 0.01) in the post-operative air, bone conduction and air-bone gap. There was no statistically significant difference (> 0.01) between the post-operative hearing results (bone conduction, air conduction, air-bone gap) using the two pistons. The mean ABG improvement was respectively 16.63 dB in the SCP group and 20.59 dB in the PCP group. The titanium Soft clip piston (SCP) is a good alternative to the Portmann clip piston (PCP). Nevertheless there are some differences in the surgical fixing of these two pistons in the correct position.

  5. Comparison of titanium and Robinson stainless steel stapes piston prostheses.

    PubMed

    Lippy, William H; Burkey, John M; Schuring, Arnold G; Berenholz, Leonard P

    2005-09-01

    Although stainless steel stapes prostheses have generally been considered magnetic resonance imaging safe, there is concern that this may change with the development of more powerful imaging systems. The objective of the study was to determine whether a titanium piston stapes prosthesis would be audiometrically and surgically equivalent to a Robinson stainless steel piston for stapedectomy. Retrospective chart review. Private otology practice. In all, 50 patients underwent stapedectomy with a Gyrus titanium piston prosthesis. These patients were matched on the basis of age and preoperative bone-conduction scores with patients who underwent stapedectomy with a Robinson stainless steel piston prosthesis. Audiometric results are analyzed, and surgical complications noted. There was no significant difference between groups in hearing improvement or postoperative air-bone gap. The mean four-frequency hearing improvement was 27.7 dB for the stainless steel group and 27.8 dB for the titanium group. The mean postoperative air-bone gap was 2.65 dB for the stainless steel group and 2.60 for the titanium group. Neither group had a surgical complication. The titanium stapes prosthesis is a good alternative to a stainless steel prosthesis.

  6. Carbon/PEEK composite materials as an alternative for stainless steel/titanium hip prosthesis: a finite element study.

    PubMed

    Rezaei, Farshid; Hassani, Kamran; Solhjoei, Nosratollah; Karimi, Alireza

    2015-12-01

    Total hip replacement (THR) has been ranked within the most typical surgical processes in the world. The durability of the prosthesis and loosening of prosthesis are the main concerns that mostly reported after THR surgeries. In THR, the femoral prosthesis can be fixed by either cement or cementless methods in the patient's bones. In both procedures, the stability of the prosthesis in the hosted bone has a key asset in its long-term durability and performance. This study aimed to execute a comparative finite element simulation to assess the load transfer between the prosthesis, which is made of carbon/PEEK composite and stainless steel/titanium, and the femur bone. The mechanical behavior of the cortical bone was assumed as a linear transverse isotropic while the spongy bone was modeled like a linear isotropic material. The implants were made of stainless steel (316L) and titanium alloy as they are common materials for implants. The results showed that the carbon/PEEK composites provide a flatter load transfer from the upper body to the leg compared to the stainless steel/titanium prosthesis. Furthermore, the results showed that the von Mises stress, principal stress, and the strain in the carbon/PEEK composites prosthesis were significantly lower than that made of the stainless steel/titanium. The results also imply that the carbon/PEEK composites can be applied to introduce a new optimum design for femoral prosthesis with adjustable stiffness, which can decrease the stress shielding and interface stress. These findings will help clinicians and biomedical experts to increase their knowledge about the hip replacement.

  7. Dual-energy CT and ceramic or titanium prostheses material reduce CT artifacts and provide superior image quality of total knee arthroplasty.

    PubMed

    Kasparek, Maximilian F; Töpker, Michael; Lazar, Mathias; Weber, Michael; Kasparek, Michael; Mang, Thomas; Apfaltrer, Paul; Kubista, Bernd; Windhager, Reinhard; Ringl, Helmut

    2018-06-07

    To evaluate the influence of different scan parameters for single-energy CT and dual-energy CT, as well as the impact of different material used in a TKA prosthesis on image quality and the extent of metal artifacts. Eight pairs of TKA prostheses from different vendors were examined in a phantom set-up. Each pair consisted of a conventional CoCr prosthesis and the corresponding anti-allergic prosthesis (full titanium, ceramic, or ceramic-coated) from the same vendor. Nine different (seven dual-energy CT and two single-energy CT) scan protocols with different characteristics were used to determine the most suitable CT protocol for TKA imaging. Quantitative image analysis included assessment of blooming artifacts (metal implants appear thicker on CT than they are, given as virtual growth in mm in this paper) and streak artifacts (thick dark lines around metal). Qualitative image analysis was used to investigate the bone-prosthesis interface. The full titanium prosthesis and full ceramic knee showed significantly fewer blooming artifacts compared to the standard CoCr prosthesis (mean virtual growth 0.6-2.2 mm compared to 2.9-4.6 mm, p < 0.001). Dual-energy CT protocols showed less blooming (range 3.3-3.8 mm) compared to single-energy protocols (4.6-5.5 mm). The full titanium and full ceramic prostheses showed significantly fewer streak artifacts (mean standard deviation 77-86 Hounsfield unit (HU)) compared to the standard CoCr prosthesis (277-334 HU, p < 0.001). All dual-energy CT protocols had fewer metal streak artifacts (215-296 HU compared to single-energy CT protocols (392-497 HU)). Full titanium and ceramic prostheses were ranked superior with regard to the image quality at the bone/prosthesis interface compared to a standard CoCr prosthesis, and all dual-energy CT protocols were ranked better than single-energy protocols. Dual-energy CT and ceramic or titanium prostheses reduce CT artifacts and provide superior image quality of total knee arthroplasty at the bone/prosthesis interface. These findings support the use of dual-energy CT as a solid imaging base for clinical decision-making and the use of full-titanium or ceramic prostheses to allow for better CT visualization of the bone-prosthesis interface.

  8. Chest-wall reconstruction with a customized titanium-alloy prosthesis fabricated by 3D printing and rapid prototyping.

    PubMed

    Wen, Xiaopeng; Gao, Shan; Feng, Jinteng; Li, Shuo; Gao, Rui; Zhang, Guangjian

    2018-01-08

    As 3D printing technology emerge, there is increasing demand for a more customizable implant in the repair of chest-wall bony defects. This article aims to present a custom design and fabrication method for repairing bony defects of the chest wall following tumour resection, which utilizes three-dimensional (3D) printing and rapid-prototyping technology. A 3D model of the bony defect was generated after acquiring helical CT data. A customized prosthesis was then designed using computer-aided design (CAD) and mirroring technology, and fabricated using titanium-alloy powder. The mechanical properties of the printed prosthesis were investigated using ANSYS software. The yield strength of the titanium-alloy prosthesis was 950 ± 14 MPa (mean ± SD), and its ultimate strength was 1005 ± 26 MPa. The 3D finite element analyses revealed that the equivalent stress distribution of each prosthesis was unifrom. The symmetry and reconstruction quality contour of the repaired chest wall was satisfactory. No rejection or infection occurred during the 6-month follow-up period. Chest-wall reconstruction with a customized titanium-alloy prosthesis is a reliable technique for repairing bony defects.

  9. Titanium clip ball joint: a partial ossicular reconstruction prosthesis.

    PubMed

    Beutner, Dirk; Luers, Jan Christoffer; Bornitz, Matthias; Zahnert, Thomas; Huttenbrink, Karl-Bernd

    2011-06-01

    To describe a new titanium clip prosthesis for partial ossicular reconstruction with a micro ball joint in the headplate for compensation of tympanic membrane displacements. Laboratory experiments followed by 18 consecutive patients. A micro ball joint was implemented into a headplate of titanium middle ear prosthesis. First, the new prosthesis was tested in the laboratory in temporal bone experiments. Second, the new prosthesis was clinically installed in 18 patients. Results of laser Doppler vibrometry and force measurements in the laboratory experiments, analysis of a questionnaire, and preoperative and postoperative pure tone audiometry. The frictional resistance in the joint was measured to be 12 mN that should allow for adequate mobility under physiologic conditions. The effective sound transmission of the prosthesis was demonstrated by laser Doppler vibrometry. Intraoperatively, the installation of the prosthesis was always straightforward with headplate prosthesis shaft angles between 60 and 90 degrees. Postoperatively, pure tone audiometry revealed satisfying hearing results with a remaining average air-bone gap of 18.2 dB over the frequencies 500, 1,000, 2,000, and 3,000 Hz. No signs of prosthesis dislocation were discovered within the follow-up period of approximately 6 months. The experimental data show that the new modified prosthesis headplate fulfills the requirements necessary for sound transmission. The joint allows the plate to follow movements of the tympanic membrane. This characteristic in conjunction with the proven clip design ensure for optimal prosthesis placement and effectiveness.

  10. Teflon Implants Versus Titanium Implants in Stapes Surgery.

    PubMed

    Bansal, Mohan

    2016-03-01

    Otosclerosis is the most common cause of bilateral gradually progressive conductive hearing loss with normal tympanic membrane and Eustachian tube. Otosclerosis surgical treatment is one of the most gratifying operations in Otorhinolaryngology. It is not only the surgical techniques but also the prosthesis which are evolving in the attempt of providing best hearing results. Teflon piston is the most commonly employed prosthesis in stapes surgery. Titanium pistons are relatively the new development in the evolution of stapes prosthesis. The aim of this review article is to know and compare the surgical technicalities and postoperative outcomes including hearing improvement after the use of Teflon and titanium stapes piston. The adverse reactions occurred during follow-up were taken into consideration. The data in this article are supported by a Medline search. The use of both the prosthesis gave good results in cases of otosclerosis. The placement of titanium soft clip design was found easier than the earlier àWengen design of clip piston.

  11. Clinical evaluation of immediate loading of electroeroded screw-retained titanium fixed prostheses supported by tilted implant: a multicenter retrospective study.

    PubMed

    Acocella, Alessandro; Ercoli, Carlo; Geminiani, Alessandro; Feng, Changyong; Billi, Mauro; Acocella, Gabriele; Giannini, Domenico; Sacco, Roberto

    2012-05-01

    Immediate occlusal loading of dental implants in the edentulous mandible has proven to be an effective, reliable, and predictable treatment protocol. However, there is limited long-term data available in the literature, when an electroeroded definitive cast-titanium fixed prosthesis is used for this treatment protocol. The aim of this study was to evaluate the clinical effectiveness of dental implants (Astra Tech Dental, Mölndal, Sweden) in the edentulous mandible immediately loaded with an electroeroded cast-titanium screw-retained fixed prosthesis. Forty-five patients received five implants each in the interforaminal area. All the implants were inserted with torque up to 40 Ncm and the distal implants were distally tilted approximately 20 to 30 degrees to minimize the length of posterior cantilevers. Implants were loaded within 48 hours of placement with an acrylic resin-titanium screw-retained prosthesis fabricated by electroerosion. Two of the 225 inserted implants failed after 3 and 16 months of healing, respectively, with a cumulative survival rate of 99.1% and a prosthetic survival rate of 97.8%. Immediate loading of tilted dental implants inserted in the edentulous mandible with a screw-retained titanium definitive prosthesis fabricated with electrical discharge machining provide reliable and predictable results. © 2011 Wiley Periodicals, Inc.

  12. Digital data acquisition for a CAD/CAM-fabricated titanium framework and zirconium oxide restorations for an implant-supported fixed complete dental prosthesis.

    PubMed

    Lin, Wei-Shao; Metz, Michael J; Pollini, Adrien; Ntounis, Athanasios; Morton, Dean

    2014-12-01

    This dental technique report describes a digital workflow with digital data acquisition at the implant level, computer-aided design and computer-aided manufacturing fabricated, tissue-colored, anodized titanium framework, individually luted zirconium oxide restorations, and autopolymerizing injection-molded acrylic resin to fabricate an implant-supported, metal-ceramic-resin fixed complete dental prosthesis in an edentulous mandible. The 1-step computer-aided design and computer-aided manufacturing fabrication of titanium framework and zirconium oxide restorations can provide a cost-effective alternative to the conventional metal-resin fixed complete dental prosthesis. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  13. A comparison of laser-welded titanium and conventional cast frameworks supported by implants in the partially edentulous jaw: a 3-year prospective multicenter study.

    PubMed

    Jemt, T; Henry, P; Lindén, B; Naert, I; Weber, H; Bergström, C

    2000-01-01

    The purpose of this prospective multicenter study was to evaluate and compare the clinical performance of laser-welded titanium fixed partial implant-supported prostheses with conventional cast frameworks. Forty-two partially edentulous patients were provided with Brånemark system implants and arranged into 2 groups. Group A was provided with a conventional cast framework with porcelain veneers in one side of the jaw and a laser-welded titanium framework with low-fusing porcelain on the other side. The patients in group B had an old implant prosthesis replaced by a titanium framework prosthesis. The patients were followed for 3 years after prosthesis placement. Clinical and radiographic data were collected and analyzed. Only one implant was lost, and all prostheses were still in function after 3 years. The 2 framework designs showed similar clinical performance with few clinical complications. Only one abutment screw (1%) and 9 porcelain tooth units (5%) fractured. Four prostheses experienced loose gold screws (6%). In group A, marginal bone loss was similar for both designs of prostheses, with a mean of 1.0 mm and 0.3 mm in the maxilla and mandible, respectively. No bone loss was observed on average in group B. No significant relationship (P > 0.05) was observed between marginal bone loss and placement of prosthesis margin or prosthesis design. The use of laser-welded titanium frameworks seems to present similar clinical performance to conventional cast frameworks in partial implant situations after 3 years.

  14. Ultrasonic longitudinal waves to monitor the integration of titanium rods with host bone

    NASA Astrophysics Data System (ADS)

    Wang, Wentao; Lynch, Jerome P.

    2017-04-01

    Osseointegrated prostheses which integrate the prosthesis directly to the limb bone are being developed for patients that are unable to wear traditional socket prostheses. While osseointegration of the prosthesis offers amputees improvement in their quality of life, there remains a need to better understand the integration process that occurs between the bone and the prosthesis. Quantification of the degree of integration is important to track the recuperation process of the amputee, guide physical therapy regimes, and to identify when the state of integration may change (due to damage to the bone). This study explores the development of an assessment strategy for quantitatively assessing the degree of integration between an osseointegrated prosthesis and host bone. Specifically, the strategy utilizes a titanium rod prosthesis as a waveguide with guided waves used to assess the degree of integration. By controlling waveforms launched by piezoelectric wafers bonded on the percutaneous tip of the prosthesis, body waves are introduced into the waveguide with wave reflections at the boneprosthesis interface recorded by the same array. Changes in wave energy are correlated to changes at the contact interface between the titanium rod and the bone material. Both simulation and experimental tests are presented in this paper. Experimental testing is performed using a high-density polyethylene (HDPE) host because the elastic modulus and density of HDPE are close to that of human and animal bone. Results indicate high sensitivity of the longitudinal wave energy to rod penetration depth and confinement stress issued by the host bone.

  15. Using "Rebar" to Stabilize Rigid Chest Wall Reconstruction.

    PubMed

    Robinson, Lary A; Grubbs, Deanna M

    2016-04-01

    After major chest wall resection, reconstruction of the bony defect with a rigid prosthesis is mandatory to protect the underlying thoracic organs, and to prevent flail chest physiology. Although many methods have been described for chest wall reconstruction, a commonly used technique employs a composite Marlex (polypropylene) mesh with methyl-methacrylate cement sandwiched between two layers of mesh (MMS), which is tailored to the defect size and shape. In building construction, steel "rebar" is used to strengthen and reinforce masonry structures. To avoid the initial residual motion of the rigid prosthesis used to reconstruct very large defects, particularly the sternum, we devised a simple technique of adding one or more Steinmann steel pins as "rebar" to strengthen and immediately stabilize the prosthesis to the surrounding ribs and sternum. For the very large defects, particularly over the heart and great vessels, titanium mesh may also be readily added into the sandwich construction for increased strength and to prevent late prosthetic fractures. Short- and long-term results of this inexpensive modification of the MMS reconstruction technique are excellent. This modified MMS tailor-made prosthesis is only one-third the cost of the recently popular prosthetic titanium systems, takes much less operative time to create and implant, and avoids the well-described complications of late titanium bar fracture and erosion/infection as well as loosening of screws and/or titanium bars. Georg Thieme Verlag KG Stuttgart · New York.

  16. Vanadium release in whole blood, serum and urine of patients implanted with a titanium alloy hip prosthesis.

    PubMed

    Catalani, S; Stea, S; Beraudi, A; Gilberti, M E; Bordini, B; Toni, A; Apostoli, P

    2013-08-01

    Vanadium (V) is a minor constituent of the Titanium-Aluminum-Vanadium (TiAlV) alloy currently used in cementless hip prostheses. Present study aimed at verifying the correlation of vanadium levels among different matrices and assessing reference levels of the ion in a population of patients wearing a well-functioning hip prosthesis. Vanadium was measured using Inductive Coupled Plasma Mass Spectrometry (ICP-MS) in whole blood, serum and urine of 129 patients implanted with a TiAlV-alloy hip prosthesis. The values in the serum were above the upper limit of the reference values in 42% of patients (29% in urine and 13% in whole blood). A good correlation among matrices was observed (p < 0.001). The cohort of patients (N = 32) complaining of pain or in which a loosening or damage to the prosthesis was assessed showed a significantly higher excretion of vanadium in urine as compared with the remaining asymptomatic patients (p = 0.001). The 95th percentile distribution of vanadium in the cohort of patients with a well-functioning prosthesis was 0.3 μg/L in whole blood, 0.5 μg/L in serum and 2.8 μg/L in urine, higher that in the unexposed population, especially for urine. The presence of a prosthesis, even though well-functioning, may cause a possible release of vanadium into the blood and a significant urinary excretion. The reference values of vanadium of the asymptomatic patients with titanium alloy hip prostheses supplied information regarding the background exposure level of the ions and their lower and upper limits.

  17. Review of a single surgeon's stapedotomy cases performed with a nickel titanium prosthesis over a 14-year period.

    PubMed

    Justicz, Natalie; Strickland, Kaitlyn F; Motamedi, Kevin K; Mattox, Douglas E

    2017-04-01

    Stapes surgery with a nickel titanium prosthesis is a safe and well-tolerated procedure that leads to a significant improvement in hearing outcomes. To identify the efficacy and safety of stapedotomy procedures performed with a nickel titanium prosthesis for patients with otosclerosis. A review of 431 unique stapedotomies performed over 14 years by a single surgeon at an academic tertiary care center yielded 312 cases with nickel titanium prosthesis that met inclusion criteria of otosclerosis diagnosis, initial surgery in operative ear, and presence of pre-operative and post-operative audiograms. Pure-tone averages (PTA) at baseline and 8 weeks after surgery were calculated over four frequencies; 0.5, 1, 2, and 4 kHz. Average air-bone gaps (ABG) were calculated from pre-operative and post-operative audiograms. Average pre-operative baseline PTA was 56.7 dB in the affected ear. Post-operative PTA was 30.1 dB, a 26.6 dB improvement. Initial average ABG was 29.7 dB, while post-operative ABG averaged 5.4 dB, a 24.2 dB improvement. Surgical success (closure of ABG within 10 dB) was achieved in 263 (84%) patients. Rate of surgical success was not correlated with age, gender, race, or affected ear. Complications included recurrent conductive hearing loss (14), progressive SNHL (4), and post-operative BPPV (3).

  18. Total Ossicular Replacement Prosthesis: A New Fat Interposition Technique.

    PubMed

    Saliba, Issam; Sabbah, Valérie; Poirier, Jackie Bibeau

    2018-01-01

    To compare audiometric results between the standard total ossicular replacement prosthesis (TORP-S) and a new fat interposition total ossicular replacement prosthesis (TORP-F) in pediatric and adult patients and to assess the complication and the undesirable outcome. This is a retrospective study. This study included 104 patients who had undergone titanium implants with TORP-F and 54 patients who had undergone the procedure with TORP-S between 2008 and 2013 in our tertiary care centers. The new technique consists of interposing a fat graft between the 4 legs of the universal titanium prosthesis (Medtronic Xomed Inc, Jacksonville, FL, USA) to provide a more stable TORP in the ovale window niche. Normally, this prosthesis is designed to fit on the stapes' head as a partial ossicular replacement prosthesis. The postoperative air-bone gap less than 25 dB for the combined cohort was 69.2% and 41.7% for the TORP-F and the TORP-S groups, respectively. The mean follow-up was 17 months postoperatively. By stratifying data, the pediatric cohort shows 56.5% in the TORP-F group (n = 52) compared with 40% in the TORP-S group (n = 29). However, the adult cohort shows 79.3% in the TORP-F group (n = 52) compared with 43.75% in the TORP-S group (n = 25). These improvements in hearing were statistically significant. There were no statistically significant differences in the speech discrimination scores. The only undesirable outcome that was statistically different between the 2 groups was the prosthesis displacement: 7% in the TORP-F group compared with 19% in the TORP-S group ( P  = .03). The interposition of a fat graft between the legs of the titanium implants (TORP-F) provides superior hearing results compared with a standard procedure (TORP-S) in pediatric and adult populations because of its better stability in the oval window niche.

  19. Total Ossicular Replacement Prosthesis: A New Fat Interposition Technique

    PubMed Central

    Saliba, Issam; Sabbah, Valérie; Poirier, Jackie Bibeau

    2018-01-01

    Objective: To compare audiometric results between the standard total ossicular replacement prosthesis (TORP-S) and a new fat interposition total ossicular replacement prosthesis (TORP-F) in pediatric and adult patients and to assess the complication and the undesirable outcome. Study design: This is a retrospective study. Methods: This study included 104 patients who had undergone titanium implants with TORP-F and 54 patients who had undergone the procedure with TORP-S between 2008 and 2013 in our tertiary care centers. The new technique consists of interposing a fat graft between the 4 legs of the universal titanium prosthesis (Medtronic Xomed Inc, Jacksonville, FL, USA) to provide a more stable TORP in the ovale window niche. Normally, this prosthesis is designed to fit on the stapes’ head as a partial ossicular replacement prosthesis. Results: The postoperative air-bone gap less than 25 dB for the combined cohort was 69.2% and 41.7% for the TORP-F and the TORP-S groups, respectively. The mean follow-up was 17 months postoperatively. By stratifying data, the pediatric cohort shows 56.5% in the TORP-F group (n = 52) compared with 40% in the TORP-S group (n = 29). However, the adult cohort shows 79.3% in the TORP-F group (n = 52) compared with 43.75% in the TORP-S group (n = 25). These improvements in hearing were statistically significant. There were no statistically significant differences in the speech discrimination scores. The only undesirable outcome that was statistically different between the 2 groups was the prosthesis displacement: 7% in the TORP-F group compared with 19% in the TORP-S group (P = .03). Conclusions: The interposition of a fat graft between the legs of the titanium implants (TORP-F) provides superior hearing results compared with a standard procedure (TORP-S) in pediatric and adult populations because of its better stability in the oval window niche. PMID:29326537

  20. Eighteen-Month Outcomes of Titanium Frameworks Using Computer-Aided Design and Computer-Aided Manufacturing Method.

    PubMed

    Turkyilmaz, Ilser; Asar, Neset Volkan

    2017-06-01

    The aim of the report is to introduce a new software and a new scanner with a noncontact laser probe and to present outcomes of computer-aided design and computer-aided manufacturing titanium frameworks using this new software and scanner with a laser probe. Seven patients received 40 implants placed using a 1-stage protocol. After all implants were planned using an implant planning software (NobelClinician), either 5 or 6 implants were placed in each edentulous arch. Each edentulous arch was treated with a fixed dental prosthesis using implant-supported complete-arch milled-titanium framework using the software (NobelProcera) and the scanner. All patients were followed up for 18 ± 3 months. Implant survival, prosthesis survival, framework fit, marginal bone levels, and maintenance requirements were evaluated. One implant was lost during the follow-up period, giving the implant survival rate of 97.5%; 0.4 ± 0.2 mm marginal bone loss was noted for all implants after 18 ± 3 months. None of the prostheses needed a replacement, indicating the prosthesis success rate of 100%. The results of this clinical study suggest that titanium frameworks fabricated using the software and scanner presented in this study fit accurately and may be a viable option to restore edentulous arches.

  1. Reconstruction of a mandibular segmental defect with a customized 3-dimensional-printed titanium prosthesis in a cat with a mandibular osteosarcoma.

    PubMed

    Liptak, Julius M; Thatcher, Graham P; Bray, Jonathan P

    2017-04-15

    CASE DESCRIPTION A 12-year-old neutered male domestic shorthair cat had been treated for a mass arising from the lingual aspect of the caudal right mandibular body. Cytoreductive surgery of the mass had been performed twice over a 2-year period, but the mass recurred following both surgeries. The mass was diagnosed as an osteosarcoma, and the cat was referred for further evaluation and treatment. CLINICAL FINDINGS Clinical findings were unremarkable, except for a 2-cm-diameter mass arising from the lingual aspect of the right mandible and mild anemia and lymphopenia. Pre- and postcontrast CT scans of the head, neck, and thorax were performed, revealing that the osteosarcoma was confined to the caudal right mandibular body, with no evidence of lymph node or pulmonary metastasis. TREATMENT AND OUTCOME The stereolithographic files of the CT scan of the head were sent for computer-aided design and manufacture of a customized 3-D-printed titanium prosthesis. Segmental mandibulectomy was performed, and the mandibular defect was reconstructed in a single stage with the 3-D-printed titanium prosthesis. The cat had 1 minor postoperative complication but had no signs of eating difficulties at any point after surgery. The cat was alive and disease free 14 months postoperatively. CLINICAL RELEVANCE Reconstruction of the mandible of a cat following mandibulectomy was possible with computer-aided design and manufacture of a customized 3-D-printed titanium prosthesis. Cats have a high rate of complications following mandibulectomy, and these initial findings suggested that mandibular reconstruction may reduce the risk of these complications and result in a better functional outcome.

  2. Custom CAD-CAM healing abutment and impression coping milled from a poly(methyl methacrylate) block and bonded to a titanium insert.

    PubMed

    Proussaefs, Periklis

    2016-11-01

    This article describes a technique in which a custom-made computer-aided design and computer-aided manufacturing (CAD-CAM) healing abutment milled from a poly(methyl methacrylate) (PMMA) block is fabricated and bonded to a titanium metal insert. An impression is made during dental implant surgery, and the CAD-CAM custom-made healing abutment is fabricated before second-stage surgery while appropriate healing time is allowed for the dental implant to osseointegrate. The contours of the healing abutment are based on the contours of a tentatively designed definitive prosthesis. The healing tissue obtains contours that will be compatible with the contours of the definitive prosthesis. After the milling process is complete, a titanium metal insert is bonded to the healing abutment. Placement of the custom-made CAD-CAM healing abutment at second-stage surgery allows the tissue to obtain contours similar to those of the definitive prosthesis. A custom-made CAD-CAM impression coping milled from a PMMA block and with a titanium insert is used for the definitive impression after the soft tissue has healed. This technique allows guided soft tissue healing by using a custom-made CAD-CAM healing abutment and impression coping. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  3. An animal model to evaluate skin-implant-bone integration and gait with a prosthesis directly attached to the residual limb

    PubMed Central

    Farrell, Brad J; Prilutsky, Boris I; Kistenberg, Robert S; Dalton, John F; Pitkin, Mark

    2014-01-01

    Background Despite the number of advantages of bone-anchored prostheses, their use in patients is limited due to the lack of complete skin-implant integration. The objective of the present study was to develop an animal model that would permit both detailed investigations of gait with a bone-anchored limb prosthesis and histological analysis of the skin-implant-bone interface after physiological loading of the implant during standing and walking. Methods Full-body mechanics of walking in two cats was recorded and analyzed before and after implantation of a percutaneous porous titanium pylon into the right tibia and attachment of a prosthesis. The rehabilitation procedures included initial limb casting, progressively increasing loading of implant, and standing and locomotor training. Detailed histological analysis of bone and skin ingrowth into implant was performed at the end of the study. Findings The two animals adopted the bone-anchored prosthesis for standing and locomotion, although loads on the prosthetic limb during walking decreased by 22% and 62%, respectively, 4 months after implantation. The animals shifted body weight to the contralateral side and increased propulsion forces by the contralateral hindlimb. Histological analysis of the limb implants demonstrated bone and skin ingrowth. Interpretation The developed animal model to study prosthetic gait and tissue integration with the implant demonstrated that porous titanium implants may permit bone and skin integration and prosthetic gait with a prosthesis. Future studies with this model will help optimize the implant and prosthesis properties. PMID:24405567

  4. Comparative electron microscopic study of the surface structure of gold, Teflon, and titanium stapes prostheses.

    PubMed

    Kwok, P; Fisch, U; Strutz, J; Jacob, P

    2001-09-01

    The goal of this study was to compare stapes prostheses of different materials with respect to their surface structures and to discuss their suitability for their use in stapes surgery. The surface condition of a stapes prosthesis plays an important role in relation to the type of membrane that forms between the stapes piston and the bony edge of the stapedotomy opening. The quality of this membrane in thickness and mobility is one of the determinants for postoperative hearing improvement. The surface conditions of gold, Teflon/steel, Teflon/platinum, and titanium stapes prostheses were examined with a scanning electron microscope. The loop, shaft, and end of each prosthesis were studied. The gold piston was the smoothest of the four pistons examined. When it was cut with a scalpel, a very smooth surface was achieved at the end area. The Teflon piston had the roughest surface. However, when it was cut, a smooth surface with a parallel arrangement of fibers resulted. Its steel loop was the smoothest, followed by gold and platinum. The titanium shaft had a scaly surface, which remained when the end of the shaft was shortened. Because a certain roughness of the piston surface is necessary for the development of a stable membrane between the piston and the edge of the stapedotomy opening, the titanium prosthesis is considered to be the most suitable for stapes surgery of the three pistons examined.

  5. Mondani intraoral welding: historical process and main practical applications.

    PubMed

    Dal Carlo, L; Pasqualini, M E; Mondani, P M; Rossi, F; Moglioni, E; Shulman, M

    2017-01-01

    The intraoral welder was invented by Dr. Pierluigi Mondani during the early 70’s to weld titanium needle implants to a titanium bar in patient’s mouth and to load them immediately by means of resin prosthesis. The clinical use documented dates back to 1972. Over the years, many practical applications have been added to the initial one, which have expanded the use of this device. In this scientific work, main applications are described. The aim of the work was to trace the historical process of intra-oral welding according to Mondani and describe the main practical applications. Intra-oral welding is a process introduced by dr. Pier Luigi Mondani of Genova (Italy) which allows to firmly conjoin titanium implants of any shape by means of a titanium bar or also directly between them in the mouth during surgery. The immediate stabilization achieved by intraoral welding increases implants success rate, allows immediate loading even in situations of bone atrophy, saves implants that are running into failure, re-evaluates fractured implants, allows to stabilize submerged implants postponing prosthesis management, allows to achieve efficient rehabilitation protocols to deal with difficult cases. The 40-years’ experience with intra-oral welding described in this article, confirms the ease of use and efficiency in providing immediate stabilization of titanium implants of all types.

  6. Transition from a fixed implant dental prosthesis to an implant overdenture in an edentulous patient: a clinical report.

    PubMed

    Ali, Bolouri; Bhavani, Venkatachalam

    2014-09-01

    The lack of planning before implant placement and restoration in edentulous patients can lead to a number of problems. Prosthodontists are often faced with the challenge of re-treating patients who have only recently been treated. Although many reports discuss retreatment by fabricating all new prosthetic components, few discuss salvaging parts of the patient's existing prosthesis. This report details the treatment of an edentulous patient who presented with an implant-retained fixed dental prosthesis in the maxillary arch and no opposing prosthesis. The transition from an implant-retained fixed dental prosthesis to a removable implant- and tissue-supported overdenture that uses the patient's existing computer-aided design/computer-aided manufacturing milled titanium substructure is described. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  7. Instant loading with intraoral welding technique and PRAMA implants: a new prosthetic approach.

    PubMed

    Celletti, R; Fanali, S; Laici, C U; Santori, C; Pignatelli, P; Sinjari, B

    2017-01-01

    When splinting multiple implants passive fit of the framework should be achieved to avoid excessive force distribution on the implants. Recently, a protocol was suggested for immediate loading of multiple implants by welding a titanium bar to implant abutments directly in the oral cavity so as to create a customized, precise and passive metal-reinforced provisional restoration. The intraoral welding technique subsequently proves to be a successful option in the full-arch immediate restorations of the mandible and maxilla. The aim of this article is to present a case report in which a new prosthetic approach, using trans-mucosal implants, is described. Dental implants are instantly loaded with a provisional prosthesis supported by an intraoral welded titanium framework to obtain a precise passive fit of the immediate loaded prosthesis.

  8. Application of porous titanium in prosthesis production using a moldless process: Evaluation of physical and mechanical properties with various particle sizes, shapes, and mixing ratios.

    PubMed

    Prananingrum, Widyasri; Tomotake, Yoritoki; Naito, Yoshihito; Bae, Jiyoung; Sekine, Kazumitsu; Hamada, Kenichi; Ichikawa, Tetsuo

    2016-08-01

    The prosthetic applications of titanium have been challenging because titanium does not possess suitable properties for the conventional casting method using the lost wax technique. We have developed a production method for biomedical application of porous titanium using a moldless process. This study aimed to evaluate the physical and mechanical properties of porous titanium using various particle sizes, shapes, and mixing ratio of titanium powder to wax binder for use in prosthesis production. CP Ti powders with different particle sizes, shapes, and mixing ratios were divided into five groups. A 90:10wt% mixture of titanium powder and wax binder was prepared manually at 70°C. After debinding at 380°C, the specimen was sintered in Ar at 1100°C without a mold for 1h. The linear shrinkage ratio of sintered specimens ranged from 2.5% to 14.2%. The linear shrinkage ratio increased with decreasing particle size. While the linear shrinkage ratio of Groups 3, 4, and 5 were approximately 2%, Group 1 showed the highest shrinkage of all. The bending strength ranged from 106 to 428MPa under the influence of porosity. Groups 1 and 2 presented low porosity followed by higher strength. The shear bond strength ranged from 32 to 100MPa. The shear bond strength was also particle-size dependent. The decrease in the porosity increased the linear shrinkage ratio and bending strength. Shrinkage and mechanical strength required for prostheses were dependent on the particle size and shape of titanium powders. These findings suggested that this production method can be applied to the prosthetic framework by selecting the material design. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. CNC-milled titanium frameworks supported by implants in the edentulous jaw: a 10-year comparative clinical study.

    PubMed

    Örtorp, Anders; Jemt, Torsten

    2012-03-01

    No long-term clinical studies covering more than 5 years are available on Computer Numeric Controlled (CNC) milled titanium frameworks. To evaluate and compare the clinical and radiographic performance of implant-supported prostheses provided with CNC titanium frameworks in the edentulous jaw with prostheses with cast gold-alloy frameworks during the first 10 years of function. Altogether, 126 edentulous patients were by random provided with 67 prostheses with titanium frameworks (test) in 23 maxillas and 44 mandibles, and with 62 prostheses with gold-alloy castings (control) in 31 maxillas and 31 mandibles. Clinical and radiographic 10-year data were collected for the groups and statistically compared on patient level. The 10-year prosthesis and implant cumulative survival rate was 95.6% compared with 98.3%, and 95.0% compared with 97.9% for test and control groups, respectively (p > .05). No implants were lost after 5 years of follow-up. Smokers lost more implants than nonsmokers after 5 years of follow-up (p < .01). Mean marginal bone loss in the test group was 0.7 mm (SD 0.61) and 0.7 mm (SD 0.85) in the maxilla and mandible, with similar pattern in the control group (p > .05), respectively. One prosthesis was lost in each group due to loss of implants, and one prosthesis failed due to framework fracture in the test group. Two metal fractures were registered in each group. More appointments of maintenance were needed for the prostheses in the maxilla compared with those in the mandible (p < .001). The frequency of complications was low with similar clinical and radiological performance for both groups during 10 years. CNC-milled titanium frameworks are a viable alternative to gold-alloy castings for restoring patients with implant-supported prostheses in the edentulous jaw. © 2009 Wiley Periodicals, Inc.

  10. 21 CFR 888.3358 - Hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... substrates, beads of the same alloy, and in the case of Ti-6Al-4V substrates, fibers of commercially pure titanium or Ti-6Al-4V alloy. The porous coating has a volume porosity between 30 and 70 percent, an average... titanium-aluminum-vanadium (Ti-6Al-4V) alloy and an acetabular component composed of an ultra-high...

  11. 21 CFR 888.3358 - Hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... substrates, beads of the same alloy, and in the case of Ti-6Al-4V substrates, fibers of commercially pure titanium or Ti-6Al-4V alloy. The porous coating has a volume porosity between 30 and 70 percent, an average... titanium-aluminum-vanadium (Ti-6Al-4V) alloy and an acetabular component composed of an ultra-high...

  12. 21 CFR 888.3358 - Hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... substrates, beads of the same alloy, and in the case of Ti-6Al-4V substrates, fibers of commercially pure titanium or Ti-6Al-4V alloy. The porous coating has a volume porosity between 30 and 70 percent, an average... titanium-aluminum-vanadium (Ti-6Al-4V) alloy and an acetabular component composed of an ultra-high...

  13. 21 CFR 888.3358 - Hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... substrates, beads of the same alloy, and in the case of Ti-6Al-4V substrates, fibers of commercially pure titanium or Ti-6Al-4V alloy. The porous coating has a volume porosity between 30 and 70 percent, an average... titanium-aluminum-vanadium (Ti-6Al-4V) alloy and an acetabular component composed of an ultra-high...

  14. A Novel Thermal-activated Shape Memory Penile Prosthesis: Comparative Mechanical Testing.

    PubMed

    Le, Brian; McVary, Kevin; McKenna, Kevin; Colombo, Alberto

    2017-01-01

    To compare a novel nickel-titanium (Ni-Ti) shape memory alloy (SMA) penile prosthesis of our own design with commercially available prostheses using a format similar to mechanical testing done at major penile prosthesis manufacturers. We evaluated the mechanical parameters of commercially available penile prostheses and used this information to guide the development of the Ni-Ti-based physiological penile prosthesis that expands and becomes erect with a small amount of heat applied. A penile prosthesis consisting of an exoskeleton of temperature-tuned Nitinol was designed and prototyped. Mechanical testing was performed in a model of penile buckling, penile lateral deviation, and original penile shape recovery commonly used by penile prosthesis manufacturers for testing. Our SMA penile prosthesis demonstrated useful mechanical characteristics, including rigidity to buckling when activated similar to an inflatable penile prosthesis (2.62 kgf SMA vs 1.42 kgf inflatable penile prosthesis vs 6.45 kgf for a malleable prosthesis). The Ni-Ti also became more pliable when deactivated within acceptable mechanical ranges of existing devices. It could be repeatedly cycled and generate a restorative force to become erect. An SMA-based penile prosthesis represents a promising new technology in the treatment of erectile dysfunction. We demonstrated that an Ni-Ti-based prosthesis can produce the mechanical forces necessary for producing a simulated erection without the need for a pump or reservoir, comparable with existing prostheses. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. MPR-CT Imaging for Stapes Prosthesis: Accuracy and Clinical Significance.

    PubMed

    Fang, Yanqing; Wang, Bing; Galvin, John J; Tao, Duoduo; Deng, Rui; Ou, Xiong; Liu, Yangwenyi; Dai, Peidong; Sha, Yan; Zhang, Tianyu; Chen, Bing

    2016-04-01

    The aims of this article are: 1) to re-evaluate the accuracy of multiple planar reconstruction computed tomography (MPR-CT) imaging on stapes-prosthesis parameters, and 2) to clarify possible relationships between prosthesis intravestibular depth and postoperative hearing outcomes. Seventy patients (46 women and 24 men; 32 right and 38 left sides) with the mean age of 40 years (range, 19-62 yr) with clinical otosclerosis. All patients underwent stapedotomy and were implanted with the same type of titanium piston prosthesis by the same surgeon. Postoperative MPR-CTs were obtained at patients' follow-up visits. The length and intravestibular depth of the stapes prosthesis (including absolute and relative depth) were calculated from the MPR-CT imaging. Relationships between the intravestibular depth of the prosthesis and hearing outcomes (pre- and postoperative audiograms) were analyzed using Spearman correlation analyses. The length of the prosthesis was overestimated by 1.8% (0.1 mm) by the MPR-CT imaging. Axial and coronal measurements were significantly correlated (p < 0.05). There was great intersubject variability in hearing outcomes differed insignificantly, regardless of intravestibular depth within the security range. No relationships were found between the intravestibular depth of the stapes prosthesis, as measured with MPR-CT, and postoperative hearing results. MPR-CT can provide an accurate estimation of stapes prosthesis parameters. However, the prosthesis intravestibular depth did not seem to affect postoperative hearing outcomes.

  16. A custom-made temporomandibular joint prosthesis for fabrication by selective laser melting: Finite element analysis.

    PubMed

    Xu, Xiangliang; Luo, Danmei; Guo, Chuanbin; Rong, Qiguo

    2017-08-01

    A novel and custom-made selective laser melting (SLM) 3D-printed alloplastic temporomandibular joint (TMJ) prosthesis is proposed. The titanium-6aluminium-4vanadium (Ti-6Al-4V) condyle component and ultra-high molecular weight polyethylene (UHMWPE) fossa component comprised the total alloplastic TMJ replacement prosthesis. For the condyle component, an optimized tetrahedral open-porous scaffold with combined connection structures, i.e. an inlay rod and an onlay plate, between the prosthesis and remaining mandible was designed. The trajectory of movement of the intact condyle was assessed via kinematic analysis to facilitate the design of the fossa component. The behaviours of the intact mandible and mandible with the prosthesis were compared. The biomechanical behaviour was analysed by assessing the stress distribution on the prosthesis and strain distribution on the mandible. After muscle force was applied, the magnitude of the compressive strain on the condyle neck of the mandible with the prosthesis was lower than that on the condyle neck of the intact mandible, with the exception of the area about the screws; additionally, the magnitude of the strain at the scaffold-bone interface was relatively high. Copyright © 2017. Published by Elsevier Ltd.

  17. [COMPUTER ASSISTED DESIGN AND ELECTRON BEAMMELTING RAPID PROTOTYPING METAL THREE-DIMENSIONAL PRINTING TECHNOLOGY FOR PREPARATION OF INDIVIDUALIZED FEMORAL PROSTHESIS].

    PubMed

    Liu, Hongwei; Weng, Yiping; Zhang, Yunkun; Xu, Nanwei; Tong, Jing; Wang, Caimei

    2015-09-01

    To study the feasibility of preparation of the individualized femoral prosthesis through computer assisted design and electron beammelting rapid prototyping (EBM-RP) metal three-dimensional (3D) printing technology. One adult male left femur specimen was used for scanning with 64-slice spiral CT; tomographic image data were imported into Mimics15.0 software to reconstruct femoral 3D model, then the 3D model of individualized femoral prosthesis was designed through UG8.0 software. Finally the 3D model data were imported into EBM-RP metal 3D printer to print the individualized sleeve. According to the 3D model of individualized prosthesis, customized sleeve was successfully prepared through the EBM-RP metal 3D printing technology, assembled with the standard handle component of SR modular femoral prosthesis to make the individualized femoral prosthesis. Customized femoral prosthesis accurately matching with metaphyseal cavity can be designed through the thin slice CT scanning and computer assisted design technology. Titanium alloy personalized prosthesis with complex 3D shape, pore surface, and good matching with metaphyseal cavity can be manufactured by the technology of EBM-RP metal 3D printing, and the technology has convenient, rapid, and accurate advantages.

  18. A new malleostapedotomy prosthesis. Experimental analysis by laser doppler vibrometer in fresh cadaver temporal bones.

    PubMed

    Vallejo, Luis A; Manzano, María T; Hidalgo, Antonio; Hernández, Alberto; Sabas, Juan; Lara, Hugo; Gil-Carcedo, Elisa; Herrero, David

    One of the problems with total ossicular replacement prostheses is their stability. Prosthesis dislocations and extrusions are common in middle ear surgery. This is due to variations in endo-tympanic pressure as well as design defects. The design of this new prosthesis reduces this problem by being joined directly to the malleus handle. The aim of this study is to confirm adequate acoustic-mechanical behaviour in fresh cadaver middle ear of a new total ossicular replacement prosthesis, designed using the finite elements method. Using the doppler vibrometer laser, we analysed the acoustic-mechanical behaviour of a new total ossicular replacement prosthesis in the human middle ear using 10 temporal bones from fresh cadavers. The transfer function of the ears in which we implanted the new prosthesis was superimposed over the non-manipulated ear. This suggests optimum acoustic-mechanical behaviour. The titanium prosthesis analysed in this study demonstrated optimum acoustic-mechanical behaviour. Together with its ease of implantation and post-surgical stability, these factors make it a prosthesis to be kept in mind in ossicular reconstruction. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  19. Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software.

    PubMed

    Lee, Young Han; Park, Kwan Kyu; Song, Ho-Taek; Kim, Sungjun; Suh, Jin-Suck

    2012-06-01

    To assess the usefulness of gemstone spectral imaging (GSI) dual-energy CT (DECT) with/without metal artefact reduction software (MARs). The DECTs were performed using fast kV-switching GSI between 80 and 140 kV. The CT data were retro-reconstructed with/without MARs, by different displayed fields-of-view (DFOV), and with synthesised monochromatic energy in the range 40-140 keV. A phantom study of size and CT numbers was performed in a titanium plate and a stainless steel plate. A clinical study was performed in 26 patients with metallic hardware. All images were retrospectively reviewed in terms of the visualisation of periprosthetic regions and the severity of beam-hardening artefacts by using a five-point scale. The GSI-MARs reconstruction can markedly reduce the metal-related artefacts, and the image quality was affected by the prosthesis composition and DFOV. The spectral CT numbers of the prosthesis and periprosthetic regions showed different patterns on stainless steel and titanium plates. Dual-energy CT with GSI-MARs can reduce metal-related artefacts and improve the delineation of the prosthesis and periprosthetic region. We should be cautious when using GSI-MARs because the image quality was affected by the prosthesis composition, energy (in keV) and DFOV. The metallic composition and size should be considered in metallic imaging with GSI-MARs reconstruction. • Metal-related artefacts can be troublesome on musculoskeletal computed tomography (CT). • Gemstone spectral imaging (GSI) with dual-energy CT (DECT) offers a novel solution • GSI and metallic artefact reduction software (GSI-MAR) can markedly reduce these artefacts. • However image quality is influenced by the prosthesis composition and other parameters. • We should be aware about potential overcorrection when using GSI-MARs.

  20. Effect of framework material and vertical misfit on stress distribution in implant-supported partial prosthesis under load application: 3-D finite element analysis.

    PubMed

    Bacchi, Ataís; Consani, Rafael Leonardo Xediek; Mesquita, Marcelo Ferraz; Dos Santos, Mateus Bertolini Fernandes

    2013-09-01

    This study evaluated the influence of framework material and vertical misfit on stress created in an implant-supported partial prosthesis under load application. The posterior part of a severely reabsorbed jaw with a fixed partial prosthesis above two osseointegrated titanium implants at the place of the second premolar and second molar was modeled using SolidWorks 2010 software. Finite element models were obtained by importing the solid model into an ANSYS Workbench 11 simulation. The models were divided into 15 groups according to their prosthetic framework material (type IV gold alloy, silver-palladium alloy, commercially pure titanium, cobalt-chromium alloy or zirconia) and vertical misfit level (10 µm, 50 µm and 100 µm). After settlement of the prosthesis with the closure of the misfit, simultaneous loads of 110 N vertical and 15 N horizontal were applied on the occlusal and lingual faces of each tooth, respectively. The data was evaluated using Maximum Principal Stress (framework, porcelain veneer and bone tissue) and a von Mises Stress (retention screw) provided by the software. As a result, stiffer frameworks presented higher stress concentrations; however, these frameworks led to lower stresses in the porcelain veneer, the retention screw (faced to 10 µm and 50 µm of the misfit) and the peri-implant bone tissues. The increase in the vertical misfit resulted in stress values increasing in all of the prosthetic structures and peri-implant bone tissues. The framework material and vertical misfit level presented a relevant influence on the stresses for all of the structures evaluated.

  1. Custom hip prostheses by integrating CAD and casting technology

    NASA Astrophysics Data System (ADS)

    Silva, Pedro F.; Leal, Nuno; Neto, Rui J.; Lino, F. Jorge; Reis, Ana

    2012-09-01

    Total Hip Arthroplasty (THA) is a surgical intervention that is being achieving high rates of success, leaving room to research on long run durability, patient comfort and costs reduction. Even so, up to the present, little research has been done to improve the method of manufacturing customized prosthesis. The common customized prostheses are made by full machining. This document presents a different approach methodology which combines the study of medical images, through CAD (Computer Aided Design) software, SLadditive manufacturing, ceramic shell manufacture, precision foundry with Titanium alloys and Computer Aided Manufacturing (CAM). The goal is to achieve the best comfort for the patient, stress distribution and the maximum lifetime of the prosthesis produced by this integrated methodology. The way to achieve this desiderate is to make custom hip prosthesis which are adapted to each patient needs and natural physiognomy. Not only the process is reliable, but also represents a cost reduction comparing to the conventional full machined custom hip prosthesis.

  2. Total nasal reconstruction with 3D custom made porous titanium prosthesis and free thoracodorsal artery perforator flap: A case report.

    PubMed

    Qassemyar, Quentin; Assouly, Nathaniel; Madar, Yoni; Temam, Stéphane; Kolb, Frédéric

    2018-02-21

    Total nasal reconstruction is a challenging surgical procedure which usually involves a free flap, forehead flap, and cartilage grafts. In certain failure situations where patients do not accept the idea of anaplastology, possibilities become very limited. We report the case of a patient who underwent several reconstruction steps with multiple failures including free and local flaps and cartilage harvests which showed recurrent episodes of necrosis and infection leading to melting and collapse of reconstructed structures. Furthermore, the patient did not want any anaplastological rehabilitation. We proposed to the patient an innovative method that consists to print a three-dimensional custom-made porous titanium prosthesis, based on the original shape of his nose, to replace the cartilage support. This implant was first inserted in a thoracodorsal artery perforator flap for primary integration before the free transfer of the complete structure, two months later. The free transfer was successful without any complication. A stable reconstruction and satisfying result was obtained. The patient did not want additional surgical improvement 24 months post-operatively, and resumed his professional activities. The possibility of using three-dimensional custom titanium prostheses to replace the bone and cartilage support seems to be an interesting alternative for patients in the failure situation of nasal reconstruction. © 2018 Wiley Periodicals, Inc.

  3. Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis

    PubMed Central

    Kim, Seok-Gyu; Son, Mee-Kyoung

    2015-01-01

    PURPOSE The purpose of this study was to examine the abutment screw stability of screw- and cement-retained implant-supported dental prosthesis (SCP) after simulated cement washout as well as the stability of SCP cements after complete loosening of abutment screws. MATERIALS AND METHODS Thirty-six titanium CAD/CAM-made implant prostheses were fabricated on two implants placed in the resin models. Each prosthesis is a two-unit SCP: one screw-retained and the other cemented. After evaluating the passive fit of each prosthesis, all implant prostheses were randomly divided into 3 groups: screwed and cemented SCP (Control), screwed and noncemented SCP (Group 1), unscrewed and cemented SCP (Group 2). Each prosthesis in Control and Group 1 was screwed and/or cemented, and the preloading reverse torque value (RTV) was evaluated. SCP in Group 2 was screwed and cemented, and then unscrewed (RTV=0) after the cement was set. After cyclic loading was applied, the postloading RTV was measured. RTV loss and decementation ratios were calculated for statistical analysis. RESULTS There was no significant difference in RTV loss ratio between Control and Group 1 (P=.16). No decemented prosthesis was found among Control and Group 2. CONCLUSION Within the limits of this in vitro study, the stabilities of SCP abutment screws and cement were not significantly changed after simulated cement washout or screw loosening. PMID:26140172

  4. [Possibilities of follow-up imaging after implantation of a carbon fiber-reinforced hip prosthesis].

    PubMed

    Krüger, T; Alter, C; Reichel, H; Birke, A; Hein, W; Spielmann, R P

    1998-03-01

    There are many problems in the radiological diagnosis of aseptic loosening in total hip arthroplasty. Computed tomography (CT) and magnetic resonance tomography (MRT) are not usable for metallic implants (stainless steel, cobalt alloy, titanium alloy). From April 1993 to December 1993 15 CFRP non-cemented hip prostheses have been implanted. In a prospective clinical study plane radiographs, CT and MRT have been analysed. Three stems were revised (1 femoral fracture, 1 severe thigh pain, 1 aseptic loosening). CFRP are not visible in plane radiographs. There was a complete (two-third of the cases) or nearly complete (one-third of the cases) small sclerotic interface between the prosthesis and the bone, these were apparent in CT and MRT in stable implant cases and did not have any clinical correlations. The small sclerotic interface is quite different in comparison to so called "Reactive Lines". In one case of aseptic loosening there was an interposition of soft tissue between prosthesis and bone in MRT and CT. CFRP inaugurates new diagnostic possibilities in aseptic loosening of hip prosthesis and in tumour surgery too.

  5. [Effect of CO2 laser on prostheses used in middle ear surgery].

    PubMed

    Szymański, Marcin

    2005-01-01

    The use of CO2 laser is advocated in primary and revision stapes surgery. The aim of the study was to assess the effect of CO2 laser on stapes prostheses. CO2 laser was applied on several types of stapes prostheses and PORPs, with power settings suggested by the manufacturer (continuous wave, 2 W and 6 W; 0,05 s). Application of the laser on stainless steel or titanium prosthesis did not exert any effect on the structure of the prosthesis. The use of the laser on the Teflon piston caused superficial burning with power 2 W, and melting and holes in the piston with power settings at 6W. Similar plastipore prostheses were melting. Hydroxyapatite PORP shattered after application of the laser energy. Teflon and hydroxyapatite prostheses are easily damaged by the laser energy, therefore applying a laser on them should be avoided. CO2 laser can be used on stainless steel and titanium prostheses without risk of damaging them. However the possibility of transmission of heat to the vestibule has to be taken into consideration.

  6. Comparison of Fluoroplastic Causse Loop Piston and Titanium Soft-Clip in Stapedotomy

    PubMed Central

    Faramarzi, Mohammad; Gilanifar, Nafiseh; Roosta, Sareh

    2017-01-01

    Introduction: Different types of prosthesis are available for stapes replacement. Because there has been no published report on the efficacy of the titanium soft-clip vs the fluoroplastic Causse loop Teflon piston, we compared short-term hearing results of both types of prosthesis in patients who underwent stapedotomy due to otosclerosis. Materials and Methods: A total of 57 ears were included in the soft-clip group and 63 ears were included in the Teflon-piston group. Pre-operative and post-operative air conduction, bone conduction, air-bone gaps, speech discrimination score, and speech reception thresholds were analyzed. Results: Post-operative speech reception threshold gains did not differ significantly between the two groups (P=0.919). However, better post-operative air-bone gap improvement at low frequencies was observed in the Teflon-piston group over the short-term follow-up (at frequencies of 0.25 and 0.50 kHz; P=0.007 and P=0.001, respectively). Conclusion: Similar post-operative hearing results were observed in the two groups in the short-term. PMID:28229059

  7. The innovative viscoelastic CP ESP cervical disk prosthesis with six degrees of freedom: biomechanical concepts, development program and preliminary clinical experience.

    PubMed

    Lazennec, Jean-Yves; Aaron, Alain; Ricart, Olivier; Rakover, Jean Patrick

    2016-01-01

    The viscoelastic cervical disk prosthesis ESP is an innovative one-piece deformable but cohesive interbody spacer. It is an evolution of the LP ESP lumbar disk implanted since 2006. CP ESP provides six full degrees of freedom about the three axes including shock absorbtion. The prosthesis geometry allows limited rotation and translation with resistance to motion (elastic return property) aimed at avoiding overload of the posterior facets. The rotation center can vary freely during motion. The concept of the ESP prosthesis is fundamentally different from that of the devices currently used in the cervical spine. The originality of the concept of the ESP® prosthesis led to innovative and intense testing to validate the adhesion of the viscoelastic component of the disk on the titanium endplates and to assess the mechanical properties of the PCU cushion. The preliminary clinical and radiological results with 2-year follow-up are encouraging for pain, function and kinematic behavior (range of motion and evolution of the mean centers of rotation). In this series, we did not observe device-related specific complications, misalignment, instability or ossifications. Additional studies and longer patient follow-up are needed to assess long-term reliability of this innovative implant.

  8. The LP-ESP(®) lumbar disc prosthesis with 6 degrees of freedom: development and 7 years of clinical experience.

    PubMed

    Lazennec, Jean-Yves; Aaron, Alain; Brusson, Adrien; Rakover, Jean-Patrick; Rousseau, Marc-Antoine

    2013-02-01

    The viscoelastic lumbar disk prosthesis-elastic spine pad (LP-ESP(®)) is an innovative one-piece deformable but cohesive interbody spacer providing 6 full degrees of freedom about the 3 axes, including shock absorption. A 20-year research program has demonstrated that this concept provides mechanical properties very close to those of a natural disk. Improvements in technology have made it possible to solve the problem of the bond between the elastic component and the titanium endplates and to obtain an excellent biostability. The prosthesis geometry allows limited rotation and translation with resistance to motion (elastic return property) aimed at avoiding overload of the posterior facets. The rotation center can vary freely during motion. It thus differs substantially from current prostheses, which are 2- or 3-piece devices involving 1 or 2 bearing surfaces and providing 3 or 5 degrees of freedom. This design and the adhesion-molding technology differentiate the LP-ESP prosthesis from other mono-elastomeric prostheses, for which the constraints of shearing during rotations or movement are absorbed at the endplate interface. Seven years after the first implantation, we can document in a solid and detailed fashion the course of clinical outcomes and the radiological postural and kinematic behavior of this prosthesis.

  9. A review of clinical and technical considerations for fixed and removable implant prostheses in the edentulous mandible.

    PubMed

    Zitzmann, Nicola Ursula; Marinello, Carlo Paolo

    2002-01-01

    The aim of the present article is to review some of the technical treatment options for implant prostheses restoring the edentulous mandible, mainly based on the Brånemark system. Clinical and technical aspects are discussed for the three established concepts: (1) implant-supported fixed prosthesis, (2) removable implant-supported overdenture, and (3) combined implant-retained and soft tissue-supported overdenture prosthesis. The framework of an implant-supported fixed screw-retained prosthesis can be processed in gold, Co-Cr alloy, or titanium with casting, laser-welding, or milling techniques. To improve the stability and retention of a conventional complete denture, one to four implants are indicated, and unsplinted (single attachments) or splinted designs (bar systems) can be applied. The design of the overdenture prosthesis must be carefully planned according to the requirements to ensure adequate stability and optimal form, contour, and esthetics, and the patient's best comfort. A large variety of different treatment modalities exist for both the fixed and removable mandibular implant prosthesis. Clinical and technical aspects should be considered at the beginning of the treatment to: (1) select the optimal implant position, (2) establish an adequate number of functional units, (3) select the appropriate retainers, and (4) apply the best technique for framework processing and veneering.

  10. Cast titanium overlay denture for a geriatric patient with a reduced vertical dimension.

    PubMed

    Guttal, Satyabodh; Patil, Narendra P

    2005-12-01

    An older patient reporting to the dental surgery for his/her dental treatment is becoming a common occurrence. Improved oral hygiene has meant that teeth are retained for a longer time, along with the potential problems of attrition, decreased vertical dimension, temporomandibular joint discomfort/strain, and poor aesthetics. The case in question is that of a 65-year-old male patient who had severe attrition in the lower arch, temporomandibular joint pain and reduced vertical dimension. The maxillary arch had previously been restored with a fixed partial prosthesis. For restoration of the lower teeth, a removable cast titanium overlay denture was fabricated incorporating an increased vertical dimension. Porcelain facings were placed to restore the aesthetics of the anterior teeth. The titanium was cast in a semi-automatic electric arc, pressure type casting machine. A titanium overlay denture with porcelain facing on the anterior teeth may provide a means of restoring a patient's concerns regarding aesthetics and function.

  11. 21 CFR 888.3540 - Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...: Articulating Surfaces Made of Metal, Ceramic and Plastic Materials,” and (viii) ISO 9001:1994 “Quality Systems... of Porous Metal Coatings,” (v) F 1108-97 “Titanium-6 Aluminum-4 Vanadium Alloy Castings for Surgical Implants,” (vi) F 1147-95 “Test Method for Tension Testing of Porous Metal Coatings,” (vii) F 1537-94...

  12. 21 CFR 888.3540 - Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...: Articulating Surfaces Made of Metal, Ceramic and Plastic Materials,” and (viii) ISO 9001:1994 “Quality Systems... of Porous Metal Coatings,” (v) F 1108-97 “Titanium-6 Aluminum-4 Vanadium Alloy Castings for Surgical Implants,” (vi) F 1147-95 “Test Method for Tension Testing of Porous Metal Coatings,” (vii) F 1537-94...

  13. 21 CFR 888.3540 - Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...: Articulating Surfaces Made of Metal, Ceramic and Plastic Materials,” and (viii) ISO 9001:1994 “Quality Systems... of Porous Metal Coatings,” (v) F 1108-97 “Titanium-6 Aluminum-4 Vanadium Alloy Castings for Surgical Implants,” (vi) F 1147-95 “Test Method for Tension Testing of Porous Metal Coatings,” (vii) F 1537-94...

  14. Design of Composite Hip Prostheses Considering the Long-Term Behavior of the Femur

    NASA Astrophysics Data System (ADS)

    Lim, Jong Wan; Jeong, Jae Youn; Ha, Sung Kyu

    A design method for the hip prosthesis is proposed which can alleviate problems associated with stress shielding, proximal loosening and the high stress of bone-implant interfaces after total hip replacement. The stress shielding which may lead to bone resorption, can cause a loosening of the stem and a fracture of femoral bone. Generally the composites were more suitable for hip prosthesis material in the long-term stability than metallic alloy because design cases of composite materials produced less stress shielding than titanium alloy. A bone remodeling algorithm was implemented in a nonlinear finite element program to predict the long-term performance of the hip prosthesis. The three neck shapes and three cross sections of composite hip were examined. It was found that the stress concentration in the distal region of the titanium stem which may cause the patient's thigh pains was reduced using composite material. The head neck shape was closely related with the cortical bone resorption and the cancellous bone apposition at proximal region whereas the cross-section was closely related with the relative micromotion between interfaces. The convex head neck type with the quadrangle cross-section produced less subsidence at proximal region on the medial side than the others. For all composite material cases, the cancellous bone apposition occurred at partial interfaces, which may result in a stable bio-fixation. The design performances of the convex neck head type with the hexagonal cross-section designed to insure the long-term stability were found to be more suitable than the others.

  15. Titanium in dentistry: historical development, state of the art and future perspectives.

    PubMed

    Jorge, Juliana Ribeiro Pala; Barão, Valentim Adelino; Delben, Juliana Aparecida; Faverani, Leonardo Perez; Queiroz, Thallita Pereira; Assunção, Wirley Gonçalves

    2013-06-01

    Titanium is a metallic element known by several attractive characteristics, such as biocompatibility, excellent corrosion resistance and high mechanical resistance. It is widely used in Dentistry, with high success rates, providing a favorable biological response when in contact with live tissues. Therefore, the objective of this study was to describe the different uses of titanium in Dentistry, reviewing its historical development and discoursing about its state of art and future perspective of its utilization. A search in the MEDLINE/PubMed database was performed using the terms 'titanium', 'dentistry' and 'implants'. The title and abstract of articles were read, and after this first screening 20 articles were selected and their full-texts were downloaded. Additional text books and manual search of reference lists within selected articles were included. Correlated literature showed that titanium is the most used metal in Implantology for manufacturing osseointegrated implants and their systems, with a totally consolidated utilization. Moreover, titanium can be also employed in prosthodontics to obtain frameworks. However, problems related to its machining, casting, welding and ceramic application for dental prosthesis are still limiting its use. In Endodontics, titanium has been used in association to nickel for manufacturing rotatory instruments, providing a higher resistance to deformation. However, although the different possibilities of using titanium in modern Dentistry, its use for prostheses frameworks still needs technological improvements in order to surpass its limitations.

  16. Micromachined electrode array

    DOEpatents

    Okandan, Murat; Wessendorf, Kurt O.

    2007-12-11

    An electrode array is disclosed which has applications for neural stimulation and sensing. The electrode array, in certain embodiments, can include a plurality of electrodes each of which is flexibly attached to a common substrate using a plurality of springs to allow the electrodes to move independently. In other embodiments of the electrode array, the electrodes can be fixed to the substrate. The electrode array can be formed from a combination of bulk and surface micromachining, and can include electrode tips having an electroplated metal (e.g. platinum, iridium, gold or titanium) or a metal oxide (e.g. iridium oxide) for biocompatibility. The electrode array can be used to form a part of a neural prosthesis, and is particularly well adapted for use in an implantable retinal prosthesis.

  17. Cellular-dendritic transition in directionally solidified binary alloys

    NASA Technical Reports Server (NTRS)

    Tewari, S. N.; Laxmanan, V.

    1987-01-01

    The microstructural development of binary alloys during directional solidification is studied. Cellular growth data for the Al-Cu and Pb-Sn binary alloy systems are analyzed in order evaluate the criteria of Kurz and Fisher (1981) and Trivedi (1984) for cellular-dendritic transition. It is observed that the experimental growth values do not correlate with the Kurz and Fisher or Trivedi data.

  18. Complications and Clinical Considerations of the Implant-Retained Zirconia Complete-Arch Prosthesis with Various Opposing Dentitions.

    PubMed

    Gonzalez, Jorge; Triplett, Robert G

    To evaluate the performance of the implant-retained zirconia complete-arch prosthesis with various opposing dentitions. The 40 patients included in this retrospective case series study were treated with one or two implant-retained zirconia complete-arch prostheses (ZIRCAP) using the Zirkonzahn protocol. Prettau zirconia frames were created with strategic cutbacks in the structure to extend zirconia incisal coverage of the esthetic anterior sextants and complete monolithic zirconia in the molar areas; subsequent layers of porcelain were applied to nonfunctional and esthetic areas. Patients had three possible occlusal scenarios: (1) maxillary ZIRCAP and mandibular ZIRCAP, (2) maxillary ZIRCAP and mandibular natural dentition, and (3) maxillary ZIRCAP and mandibular conventional hybrid prosthesis. Complications were recorded during follow-up appointments 3, 6, and 12 months after definitive prosthesis delivery. The mean treatment observation period was 33 months. Eight prosthetic complications were noted for the 40 implant-retained zirconia complete-arch prostheses (18.18%), including six cases of minor porcelain chipping and two cases of debonding of the metal insert from the zirconia framework. Maxillary ZIRCAP opposing mandibular ZIRCAP and maxillary ZIRCAP opposing mandibular natural dentition occlusal scenarios presented the same complication ratio of 4. No complications were seen in the maxillary ZIRCAP opposing mandibular conventional hybrid prosthesis group, yet 16 complications were found as denture tooth fractures in 12 mandibular conventional hybrid prostheses (ratio of 0.75). The results indicate that the implant-retained zirconia complete-arch prosthesis offers acceptable performance for use as an alternative to the conventional titanium framework acrylic veneer prosthesis for complete edentulism with a lower incidence of prosthetic complications and fewer maintenance appointments. Chipping of veneering porcelain was the most common complication, but a low incidence was observed in this study. Acrylic denture teeth may represent the weakest link when restoring complete edentulism with a maxillary ZIRCAP and mandibular conventional hybrid prosthesis.

  19. Comparison of hearing results of nitinol SMART stapes piston prosthesis with conventional piston prostheses: postoperative results of nitinol stapes prosthesis.

    PubMed

    Harris, Jeffrey P; Gong, Shusheng

    2007-08-01

    Recently, a new stapedotomy piston prosthesis, which is a composite metal alloy of nickel and titanium known as nitinol, has been introduced into medical use. This biocompatible alloy has the unique property of shape-memory, which permits tight self-crimping when heat is applied to the wire. To substantiate the favorable initial observations with the SMART piston, this study was undertaken to compare these results (n=26) with those obtained using conventional stainless steel or platinum ribbon prostheses (n=28). Prospective consecutive case review: consecutive cases performed by the same surgeon were analyzed. Tertiary referral center. Fifty-four healthy patients with otosclerosis. Stapedotomy using either SMART prosthesis or conventional prosthesis. Hearing outcomes by audiological assessment. The postoperative hearing mean pure-tone average was 24.81+/-16.20 dBHL for Group 1 (SMART prosthesis) and 27.46+/-15.57 dBHL for Group 2 (conventional prosthesis). Postoperative mean air-bone gap was 7.07+/-8.14 dBHL for Group 1 and 6.38+/-7.54 dBHL for Group 2 using 0.5-, 1-, 2-, and 4-kHz frequencies. When analyzed according to the American Academy of Otolaryngology-Head & Neck Surgery reporting criteria using an estimate of 3 kHz as a mean of the 2-and 4-kHz values, the postoperative mean air-bone gap was 5.42+/-5.4 dBHL for Group 1 SMART and 5.98+/-5.47 dBHL for Group 2 conventional prostheses. Postoperative speech discrimination scores were 96%+/-8.64% and 97%+/-5.9%, respectively. These differences were not shown to be statistically different. Results demonstrate that experienced surgeons may achieve comparable results with both prostheses; however, the ease of self-crimping and the tightness of the crimp may provide advantages that may have long-term benefits. The potential issue of nickel allergy is important when considering patients for this prosthesis.

  20. Titanium Mesh Shaping and Fixation for the Treatment of Comminuted Mandibular Fractures.

    PubMed

    Dai, Jiewen; Shen, Guofang; Yuan, Hao; Zhang, Wenbin; Shen, Shunyao; Shi, Jun

    2016-02-01

    Treating comminuted mandibular fractures remains a challenge. In this study, we used titanium mesh to treat comminuted mandibular fractures. Nine patients with traumatically comminuted mandibular fractures who received open reduction and internal stable fixation with titanium mesh were retrospectively reviewed. Open reduction-internal stable fixation was performed 7 to 10 days after primary debridement of the facial trauma. After the fractured mandible and the displaced fragments were reduced, the titanium mesh was reshaped according to the morphology of the mandible, and the reduced bone fragments were fixed with the reshaped titanium mesh and screws. Then, the surgical effects were evaluated during routine follow-up. Most of the displaced fragments were preserved and exhibited a favorable shaping ability in restoring the morphology of the mandible during surgery. No intraoperative complications were encountered. In addition, all patients were infection free, with no obvious resorption in the fixed fragments after surgery. The mandible also exhibited favorable morphology and offered sufficient bone mass for dental implantation or a denture prosthesis. We conclude that titanium mesh shaping and fixation can effectively treat comminuted mandibular fractures with little bone fragment loss, little soft tissue exposure, a low infection rate, and favorable mandibular morphology. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Metallic wear in failed titanium-alloy total hip replacements. A histological and quantitative analysis.

    PubMed

    Agins, H J; Alcock, N W; Bansal, M; Salvati, E A; Wilson, P D; Pellicci, P M; Bullough, P G

    1988-03-01

    We conducted extensive histological examination of the tissues that were adjacent to the prosthesis in nine hips that had a failed total arthroplasty. The prostheses were composed of titanium alloy (Ti-6Al-4V) and ultra-high molecular weight polyethylene. The average time that the prosthesis had been in place in the tissue was 33.5 months (range, eleven to fifty-seven months). Seven arthroplasties were revised because of aseptic loosening and two, for infection. In eight hips cement had been used and in one (that had a porous-coated implant for fifty-two months) no cement had been utilized. Intense histiocytic and plasma-cell reaction was noted in the pseudocapsular tissue. There was copious metallic staining of the lining cells. Polyethylene debris and particles of cement with concomitant giant-cell reaction were present in five hips. Atomic absorption spectrophotometry revealed values for titanium of fifty-sic to 3700 micrograms per gram of dry tissue (average, 1047 micrograms per gram; normal, zero microgram per gram), for aluminum of 2.1 to 396 micrograms per gram (average, 115 micrograms per gram; normal, zero micrograms per gram), and for vanadium of 2.9 to 220 micrograms per gram (average, sixty-seven micrograms per gram; normal, 1.2 micrograms per gram). The highest values were found in the hip in which surgical revision was performed at fifty-seven months. The concentrations of the three elements in the soft tissues were similar to those in the metal of the prostheses. The factors to which failure was attributed were: vertical orientation of the acetabular component (five hips), poor cementing technique on the femoral side (three hips), infection (two hips), and separation of a sintered pad made of pure titanium (one hip). A femoral component that is made of titanium alloy can undergo severe wear of the surface and on the stem, where it is loose, with liberation of potentially toxic local concentrations of metal debris into the surrounding tissues. It may contribute to infection and loosening.

  2. In vivo operation of the Boston 15-channel wireless subretinal visual prosthesis

    NASA Astrophysics Data System (ADS)

    Shire, Douglas B.; Doyle, Patrick; Kelly, Shawn K.; Gingerich, Marcus D.; Chen, Jinghua; Cogan, Stuart F.; Drohan, William A.; Mendoza, Oscar; Theogarajan, Luke; Wyatt, John; Rizzo, Joseph F.

    2010-02-01

    This presentation concerns the engineering development of the Boston visual prosthesis for restoring useful vision to patients blind with degenerative retinal disease. A miniaturized, hermetically-encased, 15-channel wirelessly-operated retinal prosthetic was developed for implantation and pre-clinical studies in Yucatan mini-pig animal models. The prosthesis conforms to the eye and drives a microfabricated polyimide stimulating electrode array having sputtered iridium oxide electrodes. This array is implanted into the subretinal space using a specially-designed ab externo surgical technique; the bulk of the prosthesis is on the surface of the sclera. The implanted device includes a hermetic titanium case containing a 15-channel stimulator chip; secondary power/data receiving coils surround the cornea. Long-term in vitro pulse testing was also performed on the electrodes to ensure their stability over years of operation. Assemblies were first tested in vitro to verify wireless operation of the system in biological saline using a custom RF transmitter circuit and primary coils. Stimulation pulse strength, duration and frequency were programmed wirelessly using a computer with a custom graphical user interface. Operation of the retinal implant was verified in vivo in 3 minipigs for more than three months by measuring stimulus artifacts on the eye surface using contact lens electrodes.

  3. Biofilm formation and design features of indwelling silicone rubber tracheoesophageal voice prostheses--an electron microscopical study.

    PubMed

    Leunisse, C; van Weissenbruch, R; Busscher, H J; van der Mei, H C; Dijk, F; Albers, F W

    2001-01-01

    After total laryngectomy, voice can be restored with a silicone rubber tracheoesophageal voice prosthesis. However, biofilm formation and subsequent deterioration of the silicone material of the prosthesis will limit device life by impairing valve function. To simulate the natural process of biofilm development under dynamic nutrient conditions, a modified Robbins device was used to evaluate the biofilm-related valve dysfunction of the Groningen, Provox2, Blom-Singer indwelling, and VoiceMaster voice prostheses. Obstruction of the semicircular slit-valved Groningen prosthesis leading to increased airway resistance was caused not only by a buildup of deposits on the esophageal flange and valve hat, but also by accumulation of deposits on the semicircular valve seating. The hinged flap valved Provox2 and indwelling Blom-Singer prostheses failed to close sufficiently because of biofilm formation on the valve seating. The esophageal flange of the VoiceMaster prosthesis was affected, but the tripod structure of the ball valve was fully colonized up to the titanium sleeve, which interfered with proper valve opening and closure. These findings on biofilm formation could be used for the further development and modification of critical design features of voice prostheses to facilitate tracheoesophageal speech. Copyright 2001 John Wiley & Sons, Inc.

  4. Magnetic resonance imaging evaluation after implantation of a titanium cervical disc prosthesis: a comparison of 1.5 and 3 Tesla magnet strength.

    PubMed

    Sundseth, Jarle; Jacobsen, Eva A; Kolstad, Frode; Nygaard, Oystein P; Zwart, John A; Hol, Per K

    2013-10-01

    Cervical disc prostheses induce significant amount of artifact in magnetic resonance imaging which may complicate radiologic follow-up after surgery. The purpose of this study was to investigate as to what extent the artifact, induced by the frequently used Discover(®) cervical disc prosthesis, impedes interpretation of the MR images at operated and adjacent levels in 1.5 and 3 Tesla MR. Ten subsequent patients were investigated in both 1.5 and 3 Tesla MR with standard image sequences one year following anterior cervical discectomy with arthroplasty. Two neuroradiologists evaluated the images by consensus. Emphasis was made on signal changes in medulla at all levels and visualization of root canals at operated and adjacent levels. A "blur artifact ratio" was calculated and defined as the height of the artifact on T1 sagittal images related to the operated level. The artifacts induced in 1.5 and 3 Tesla MR were of entirely different character and evaluation of the spinal cord at operated level was impossible in both magnets. Artifacts also made the root canals difficult to assess at operated level and more pronounced in the 3 Tesla MR. At the adjacent levels however, the spinal cord and root canals were completely visualized in all patients. The "blur artifact" induced at operated level was also more pronounced in the 3 Tesla MR. The artifact induced by the Discover(®) titanium disc prosthesis in both 1.5 and 3 Tesla MR, makes interpretation of the spinal cord impossible and visualization of the root canals difficult at operated level. Adjusting the MR sequences to produce the least amount of artifact is important.

  5. Flexible retinal electrode array

    DOEpatents

    Okandan, Murat [Albuquerque, NM; Wessendorf, Kurt O [Albuquerque, NM; Christenson, Todd R [Albuquerque, NM

    2006-10-24

    An electrode array which has applications for neural stimulation and sensing. The electrode array can include a large number of electrodes each of which is flexibly attached to a common substrate using a plurality of springs to allow the electrodes to move independently. The electrode array can be formed from a combination of bulk and surface micromachining, with electrode tips that can include an electroplated metal (e.g. platinum, iridium, gold or titanium) or a metal oxide (e.g. iridium oxide) for biocompatibility. The electrode array can be used to form a part of a neural prosthesis, and is particularly well adapted for use in an implantable retinal prosthesis where the electrodes can be tailored to provide a uniform gentle contact pressure with optional sensing of this contact pressure at one or more of the electrodes.

  6. Femtosecond pulse laser-oriented recording on dental prostheses: a trial introduction.

    PubMed

    Ichikawa, Tetsuo; Hayasaki, Yoshio; Fujita, Keiji; Nagao, Kan; Murata, Masayo; Kawano, Takanori; Chen, JianRong

    2006-12-01

    The purpose of this study was to evaluate the feasibility of using a femtosecond pulse laser processing technique to store information on a dental prosthesis. Commercially pure titanium plates were processed by a femtosecond pulse laser system. The processed surface structure was observed with a reflective illumination microscope, scanning electron microscope, and atomic force microscope. Processed area was an almost conical pit with a clear boundary. When laser pulse energy was 2 microJ, the diameter and depth were approximately 10microm and 0.2 microm respectively--whereby both increased with laser pulse energy. Further, depth of pit increased with laser pulse number without any thermal effect. This study showed that the femtosecond pulse processing system was capable of recording personal identification and optional additional information on a dental prosthesis.

  7. [Inferior hemiarthroplasty of the temporo-mandibular joint with articulated condylar prosthesis type Stryker].

    PubMed

    Bucur, A; Dincă, O; Totan, C; Ghită, V

    2007-01-01

    The optimal reconstruction of the mandible and of the temporo-mandibular joint after mandibular hemi-resection with disarticulation is still controversial in literature. This paperwork presents our experience on four cases in the reconstruction of the mandible together with the inferior arthroplasty of the temporo-mandibular joint, after the resection of extended benign tumors of the mandible, based on fibular free vascularized grafts having attached a Stryker titanium condylar prosthesis reconstructing the inferior segment of the temporo-mandibular joint. Our results for the this technique were excellent, with a functional rehabilitation very close to normal. After reviewing the various techniques and their arguments in literature, with accent on the TMJ reconstruction, we consider this method to be optimal for the reconstruction of mandibular defects in patients with neoplastic conditions.

  8. Fabrication of titanium removable dental prosthesis frameworks with a 2-step investment coating method.

    PubMed

    Koike, Mari; Hummel, Susan K; Ball, John D; Okabe, Toru

    2012-06-01

    Although pure titanium is known to have good biocompatibility, a titanium alloy with better strength is needed for fabricating clinically acceptable, partial removable dental prosthesis (RDP) frameworks. The mechanical properties of an experimental Ti-5Al-5Cu alloy cast with a 2-step investment technique were examined for RDP framework applications. Patterns for tests for various properties and denture frameworks for a preliminary trial casting were invested with a 2-step coating method using 2 types of mold materials: a less reactive spinel compound (Al(2)O(3)·MgO) and a less expensive SiO(2)-based material. The yield and tensile strength (n=5), modulus of elasticity (n=5), elongation (n=5), and hardness (n=8) of the cast Ti-5Al-5Cu alloy were determined. The external appearance and internal porosities of the preliminary trial castings of denture frameworks (n=2) were examined with a conventional dental radiographic unit. Cast Ti-6Al-4V alloy and commercially pure titanium (CP Ti) were used as controls. The data for the mechanical properties were statistically analyzed with 1-way ANOVA (α=.05). The yield strength of the cast Ti-5Al-5Cu alloy was 851 MPa and the hardness was 356 HV. These properties were comparable to those of the cast Ti-6Al-4V and were higher than those of CP Ti (P<.05). One of the acrylic resin-retention areas of the Ti-5Al-5Cu frameworks was found to have been incompletely cast. The cast biocompatible experimental Ti-5Al-5Cu alloy exhibited high strength when cast with a 2-step coating method. With a dedicated study to determine the effect of sprue design on the quality of castings, biocompatible Ti-5Al-5Cu RDP frameworks for a clinical trial can be produced. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  9. Clinical results of Hi-tech Knee II total knee arthroplasty in patients with rheumatoid athritis: 5- to 12-year follow-up.

    PubMed

    Yamanaka, Hajime; Goto, Ken-ichiro; Suzuki, Munetaka

    2012-02-22

    Total knee arthroplasty (TKA) is a common form of treatment to relieve pain and improve function in cases of rheumatoid arthritis (RA). Good clinical outcomes have been reported with a variety of TKA prostheses. The cementless Hi-Tech Knee II cruciate-retaining (CR)-type prosthesis, which has 6 fins at the anterior of the femoral component, posterior cruciate ligament (PCL) retention, flat-on-flat surface component geometry, all-polyethylene patella, strong initial fixation by the center screw of the tibial base plate, 10 layers of titanium alloy fiber mesh, and direct compression molded ultra high molecular weight polyethylene (UHMWPE), is appropriate for TKA in the Japanese knee.The present study was performed to evaluate the clinical results of primary TKA in RA using the cementless Hi-Tech Knee II CR-type prosthesis. We performed 32 consecutive primary TKAs using cementless Hi-Tech Knee II CR-type prosthesis in 31 RA patients. The average follow-up period was 8 years 3 months. Clinical evaluations were performed according to the American Knee Society (KS) system, knee score, function score, radiographic evaluation, and complications. The mean postoperative maximum flexion angle was 115.6°, and the KS knee score and function score improved to 88 and 70 after surgery, respectively. Complications, such as infection, occurred in 1 patient and revision surgery was performed. There were no cases of loosening in this cohort, and prosthesis survival rate was 96.9% at 12 years postoperatively. These results suggest that TKA using the cementless Hi-Tech Knee II CR-type prosthesis is a very effective form of treatment in RA patients at 5 to 12 years postoperatively. Further long-term follow-up studies are required to determine the ultimate utility of this type of prosthesis.

  10. Comparative Evaluation of a Four-Implant-Supported Polyetherketoneketone Framework Prosthesis: A Three-Dimensional Finite Element Analysis Based on Cone Beam Computed Tomography and Computer-Aided Design.

    PubMed

    Lee, Ki-Sun; Shin, Sang-Wan; Lee, Sang-Pyo; Kim, Jong-Eun; Kim, Jee-Hwan; Lee, Jeong-Yol

    The purpose of this pilot study was to evaluate and compare polyetherketoneketone (PEKK) with different framework materials for implant-supported prostheses by means of a three-dimensional finite element analysis (3D-FEA) based on cone beam computed tomography (CBCT) and computer-aided design (CAD) data. A geometric model that consisted of four maxillary implants supporting a prosthesis framework was constructed from CBCT and CAD data of a treated patient. Three different materials (zirconia, titanium, and PEKK) were selected, and their material properties were simulated using FEA software in the generated geometric model. In the PEKK framework (ie, low elastic modulus) group, the stress transferred to the implant and simulated adjacent tissue was reduced when compressive stress was dominant, but increased when tensile stress was dominant. This study suggests that the shock-absorbing effects of a resilient implant-supported framework are limited in some areas and that rigid framework material shows a favorable stress distribution and safety of overall components of the prosthesis.

  11. A feasibility study for in vitro evaluation of fixation between prosthesis and bone with bone marrow-derived mesenchymal stem cells.

    PubMed

    Morita, Yusuke; Yamasaki, Kenichi; Hattori, Koji

    2010-10-01

    It is difficult to quantitatively evaluate adhesive strength between an implant and the neighboring bone using animal experiments, because the degree of fixation of an implant depends on differences between individuals and the clearance between the material and the bone resulting from surgical technique. A system was designed in which rat bone marrow cells were used to quantitatively evaluate the adhesion between titanium alloy plates and bone plates in vitro. Three kinds of surface treatment were used: a sand-blasted surface, a titanium-sprayed surface and a titanium-sprayed surface coated with hydroxyapatite. Bone marrow cells obtained from rat femora were seeded on the titanium alloy plates, and the cells were cultured between the titanium alloy plates and the bone plates sliced from porcine ilium for 2 weeks. After cultivation, adhesive strength was measured using a tensile test, after which DNA amount and Alkaline phosphatase activity were measured. The seeded cells accelerated adhesion of the titanium alloy plate to the bone plate. Adhesive strength of the titanium-sprayed surface was lower than that of the sand-blasted surface because of lower initial contact area, although there was no difference in Alkaline phosphatase activity between two surface treatments. A hydroxyapatite coating enhanced adhesive strength between the titanium alloy palate and the bone plate, as well as enhancing osteogenic differentiation of bone marrow cells. It is believed that this novel experimental method can be used to simultaneously evaluate the osteogenic differentiation and the adhesive strength of an implant during in vitro cultivation. 2010 Elsevier Ltd. All rights reserved.

  12. Direct metal laser sintering (DMLS) of a customized titanium mesh for prosthetically guided bone regeneration of atrophic maxillary arches.

    PubMed

    Ciocca, L; Fantini, M; De Crescenzio, F; Corinaldesi, G; Scotti, R

    2011-11-01

    This study describes a protocol for the direct manufacturing of a customized titanium mesh using CAD-CAM procedures and rapid prototyping to augment maxillary bone and minimize surgery when severe atrophy or post-oncological deformities are present. Titanium mesh and particulate autogenous plus bovine demineralised bone were planned for patient rehabilitation. Bone augmentation planning was performed using the pre-op CT data set in relation to the prosthetic demands, minimizing the bone volume to augment at the minimum necessary for implants. The containment mesh design was used to prototype the 0.6 mm thickness customized titanium mesh, by direct metal laser sintering. The levels of regenerated bone were calculated using the post-op CT data set, through comparison with the pre-op CT data set. The mean vertical height difference of the crestal bone was 2.57 mm, while the mean buccal-palatal dimension of thickness difference was 3.41 mm. All planned implants were positioned after an 8 month healing period using two-step implant surgery, and finally restored with a partial fixed prosthesis. We present a viable and reproducible method to determine the correct bone augmentation prior to implant placement and CAD-CAM to produce a customized direct laser-sintered titanium mesh that can be used for bone regeneration.

  13. A Bibliography on Non-Gaussian Signal Processing: 1971-1980.

    DTIC Science & Technology

    1980-08-20

    Narrowband Acoustic Signals in Noise," DDC Report AD-A069 829, May 1979. 9. Evans, James, Kersten , Paul, Kurz, Ludwik, "Robustized Recursive Esti...Kazakos, D., and Papantoni-Kazakos, P., "Nonparanietric Methods in Communication Systems," Marcel Dekker, Inc., New York, 1977. 17. Kersten , P., Kurz...ARRAY PFOCESSING 1. Adams , S.L.; Doubek, J.W., "Frequency Coherence and Time Cbherence in Random Multipath Channels", DDC Peport, PD-A047 456, August

  14. Virtual surgical planning and 3D printing in prosthetic orbital reconstruction with percutaneous implants: a technical case report

    PubMed Central

    Huang, Yu-Hui; Seelaus, Rosemary; Zhao, Linping; Patel, Pravin K; Cohen, Mimis

    2016-01-01

    Osseointegrated titanium implants to the cranial skeleton for retention of facial prostheses have proven to be a reliable replacement for adhesive systems. However, improper placement of the implants can jeopardize prosthetic outcomes, and long-term success of an implant-retained prosthesis. Three-dimensional (3D) computer imaging, virtual planning, and 3D printing have become accepted components of the preoperative planning and design phase of treatment. Computer-aided design and computer-assisted manufacture that employ cone-beam computed tomography data offer benefits to patient treatment by contributing to greater predictability and improved treatment efficiencies with more reliable outcomes in surgical and prosthetic reconstruction. 3D printing enables transfer of the virtual surgical plan to the operating room by fabrication of surgical guides. Previous studies have shown that accuracy improves considerably with guided implantation when compared to conventional template or freehand implant placement. This clinical case report demonstrates the use of a 3D technological pathway for preoperative virtual planning through prosthesis fabrication, utilizing 3D printing, for a patient with an acquired orbital defect that was restored with an implant-retained silicone orbital prosthesis. PMID:27843356

  15. Virtual surgical planning and 3D printing in prosthetic orbital reconstruction with percutaneous implants: a technical case report.

    PubMed

    Huang, Yu-Hui; Seelaus, Rosemary; Zhao, Linping; Patel, Pravin K; Cohen, Mimis

    2016-01-01

    Osseointegrated titanium implants to the cranial skeleton for retention of facial prostheses have proven to be a reliable replacement for adhesive systems. However, improper placement of the implants can jeopardize prosthetic outcomes, and long-term success of an implant-retained prosthesis. Three-dimensional (3D) computer imaging, virtual planning, and 3D printing have become accepted components of the preoperative planning and design phase of treatment. Computer-aided design and computer-assisted manufacture that employ cone-beam computed tomography data offer benefits to patient treatment by contributing to greater predictability and improved treatment efficiencies with more reliable outcomes in surgical and prosthetic reconstruction. 3D printing enables transfer of the virtual surgical plan to the operating room by fabrication of surgical guides. Previous studies have shown that accuracy improves considerably with guided implantation when compared to conventional template or freehand implant placement. This clinical case report demonstrates the use of a 3D technological pathway for preoperative virtual planning through prosthesis fabrication, utilizing 3D printing, for a patient with an acquired orbital defect that was restored with an implant-retained silicone orbital prosthesis.

  16. Functionalized coatings by cold spray: An in vitro study of micro- and nanocrystalline hydroxyapatite compared to porous titanium.

    PubMed

    Vilardell, A M; Cinca, N; Garcia-Giralt, N; Dosta, S; Cano, I G; Nogués, X; Guilemany, J M

    2018-06-01

    Three different surface treatments on a Ti6Al4V alloy have been in vitro tested for possible application in cementless joint prosthesis. All of them involve the novelty of using the Cold Spray technology for their deposition: (i) an as-sprayed highly rough titanium and, followed by the deposition of a thin hydroxyapatite layer with (ii) microcrystalline or (iii) nanocrystalline structure. Primary human osteoblasts were extracted from knee and seeded onto the three different surfaces. Cell viability was tested by MTS and LIVE/DEAD assays, cell differentiation by alkaline phosphatase (ALP) quantification and cell morphology by Phalloidin staining. All tests were carried out at 1, 7 and 14 days of cell culture. Different cell morphologies between titanium and hydroxyapatite surfaces were exhibited. At 1 day of cell culture, cells on the titanium coating were spread and flattened, expanding the filopodia actin filaments in all directions, while cells on the hydroxyapatite coatings showed round like-shape morphology due to slower attachment. Higher cell viability was detected at all times of cell culture on titanium coating due to a better attachment at 1 day. However, from 7 days of cell culture, cells on hydroxyapatite showed good attachment onto surfaces and highly increased their proliferation, mostly on nanocrystalline, achieving similar cell viability levels than titanium coatings. ALP levels were significantly higher in titanium, in part, because of greatest cell number. Overall, the best cell functional results were obtained on titanium coatings whereas microcrystalline hydroxyapatite presented the worst cellular parameters. However, results indicate that nanocrystalline hydroxyapatite coatings may achieve promising results for the faster cell proliferation once cells are attached on the surface. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Clinical results of Hi-tech Knee II total knee arthroplasty in patients with rheumatoid athritis: 5- to 12-year follow-up

    PubMed Central

    2012-01-01

    Background Total knee arthroplasty (TKA) is a common form of treatment to relieve pain and improve function in cases of rheumatoid arthritis (RA). Good clinical outcomes have been reported with a variety of TKA prostheses. The cementless Hi-Tech Knee II cruciate-retaining (CR)-type prosthesis, which has 6 fins at the anterior of the femoral component, posterior cruciate ligament (PCL) retention, flat-on-flat surface component geometry, all-polyethylene patella, strong initial fixation by the center screw of the tibial base plate, 10 layers of titanium alloy fiber mesh, and direct compression molded ultra high molecular weight polyethylene (UHMWPE), is appropriate for TKA in the Japanese knee. The present study was performed to evaluate the clinical results of primary TKA in RA using the cementless Hi-Tech Knee II CR-type prosthesis. Materials and methods We performed 32 consecutive primary TKAs using cementless Hi-Tech Knee II CR-type prosthesis in 31 RA patients. The average follow-up period was 8 years 3 months. Clinical evaluations were performed according to the American Knee Society (KS) system, knee score, function score, radiographic evaluation, and complications. Results The mean postoperative maximum flexion angle was 115.6°, and the KS knee score and function score improved to 88 and 70 after surgery, respectively. Complications, such as infection, occurred in 1 patient and revision surgery was performed. There were no cases of loosening in this cohort, and prosthesis survival rate was 96.9% at 12 years postoperatively. Conclusion These results suggest that TKA using the cementless Hi-Tech Knee II CR-type prosthesis is a very effective form of treatment in RA patients at 5 to 12 years postoperatively. Further long-term follow-up studies are required to determine the ultimate utility of this type of prosthesis. PMID:22356935

  18. The flavonoid quercetin inhibits titanium dioxide (TiO2)-induced chronic arthritis in mice.

    PubMed

    Borghi, Sergio M; Mizokami, Sandra S; Pinho-Ribeiro, Felipe A; Fattori, Victor; Crespigio, Jefferson; Clemente-Napimoga, Juliana T; Napimoga, Marcelo H; Pitol, Dimitrius L; Issa, João P M; Fukada, Sandra Y; Casagrande, Rubia; Verri, Waldiceu A

    2018-03-01

    Titanium dioxide (TiO 2 ) is a common component of orthopedic prosthesis. However, prosthesis wear releases TiO 2 , which induces inflammation and osteolysis in peri-prosthetic tissues. Quercetin is a flavonoid widely present in human diet, which presents biological activities such as antinociceptive, anti-inflammatory and antioxidant effects. Therefore, the effect of intraperitoneal treatment with quercetin in TiO 2 -induced arthritis model was evaluated. In the first set of experiments, mice received injection of TiO 2 (0.1-3 mg/knee joint) and articular mechanical hyperalgesia, edema and histopathology analysis were performed in a 30 days protocol. The dose of 3 mg of TiO 2 showed the most harmful effect, and was chosen to the following experiments. Subsequently, mice received 3 mg of TiO 2 followed by post-treatment with quercetin during 30 days. Quercetin (10-100 mg/kg) inhibited in a dose-dependent manner TiO 2 -induced knee joint mechanical hyperalgesia, edema and leukocyte recruitment and did not induce damage in major organs such as liver, kidney and stomach. The dose of 30 mg/kg was chosen for the subsequent analysis, and reduced histopathological changes such as leukocyte infiltration, vascular proliferation and synovial hyperplasia (pannus formation) on day 30 after TiO 2 challenge. The protective analgesic and anti-inflammatory mechanisms of quercetin included the inhibition of TiO 2 -induced neutrophil and macrophage recruitment, proteoglycan degradation, oxidative stress, cytokine production (TNF-α, IL-1β, IL-6, and IL-10), COX-2 mRNA expression, and bone resorption as well as activation of Nrf2/HO-1 signaling pathway. These results demonstrate the potential therapeutic applicability of the dietary flavonoid quercetin to reduce pain and inflammatory damages associated with prosthesis wear process-induced arthritis. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Passive fit of frameworks in titanium and palladium-silver alloy submitted the laser welding.

    PubMed

    de Sousa, S A; de Arruda Nobilo, M A; Henriques, G E P; Mesquita, M F

    2008-02-01

    This study evaluated the precision of fit of implant frameworks cast in titanium (cp Ti) and palladium-silver alloy (Pd-Ag), made by the one-piece cast and laser welding techniques. From a metal matrix with five implants, 20 master casts were obtained, to which replicas of implants were incorporated. On these masters 10 frameworks were made for each type of material (cp Ti and Pd-Ag alloy). Half of these were made by the one-piece cast technique and the other half by the laser welding technique. The implant/prosthesis interface was analysed and measured in the vestibular and lingual regions of the central and distal implants with the help of a measuring microscope. The results indicated that in the central cylinders, the Tukey test (P<0.0005) showed a significant difference in the passive fit between the laser-welded frameworks (34.73 microm) and those one-piece cast frameworks (151.39 microm), and as regards materials, the palladium-silver alloy (66.30 microm) showed better results than the titanium (119.83 microm). In the distal cylinders there was no significant difference between the frameworks cast in titanium and palladium-silver by the one-piece technique. However, after laser welding, there was a significant difference for the frameworks cast in titanium (31.37 microm) and palladium-silver (106.59 microm).

  20. A comparative study of zirconium and titanium implants in rat: osseointegration and bone material quality.

    PubMed

    Hoerth, Rebecca M; Katunar, María R; Gomez Sanchez, Andrea; Orellano, Juan C; Ceré, Silvia M; Wagermaier, Wolfgang; Ballarre, Josefina

    2014-02-01

    Permanent metal implants are widely used in human medical treatments and orthopedics, for example as hip joint replacements. They are commonly made of titanium alloys and beyond the optimization of this established material, it is also essential to explore alternative implant materials in view of improved osseointegration. The aim of our study was to characterize the implant performance of zirconium in comparison to titanium implants. Zirconium implants have been characterized in a previous study concerning material properties and surface characteristics in vitro, such as oxide layer thickness and surface roughness. In the present study, we compare bone material quality around zirconium and titanium implants in terms of osseointegration and therefore characterized bone material properties in a rat model using a multi-method approach. We used light and electron microscopy, micro Raman spectroscopy, micro X-ray fluorescence and X-ray scattering techniques to investigate the osseointegration in terms of compositional and structural properties of the newly formed bone. Regarding the mineralization level, the mineral composition, and the alignment and order of the mineral particles, our results show that the maturity of the newly formed bone after 8 weeks of implantation is already very high. In conclusion, the bone material quality obtained for zirconium implants is at least as good as for titanium. It seems that the zirconium implants can be a good candidate for using as permanent metal prosthesis for orthopedic treatments.

  1. Monaco and film dosimetry of 3D CRT, IMRT and VMAT cases in a realistic pelvic prosthetic phantom

    NASA Astrophysics Data System (ADS)

    Ade, Nicholas; du Plessis, F. C. P.

    2018-04-01

    The dosimetry of patients with metallic hip implants during irradiation of pelvic lesions is challenging due to dose distortions caused by implants. This work presents a dosimetric comparison of various multi-field photon-beam dose distributions in the presence of unilateral hip titanium prosthesis (UHTiP) embedded in a unique pelvic phantom made out of water-equivalent nylon slices. The impact of the UHTiP on the accuracy of dose calculations from a Monaco TPS (treatment planning system) using the X-ray voxel Monte Carlo (XVMC) algorithm was benchmarked against measured dose data using Gafchromic EBT3 film. Multi-field beam arrangements including a 4-field box, 5-field 3DCRT (three-dimensional conformal radiation therapy), 6-field IMRT (intensity modulated radiation therapy) and a single-arc VMAT (volumetric modulated arc therapy) plan were set up for 6 MV and 15 MV beams. These plans were generated for the pelvic phantom that contains the prosthesis with film inserted. Compared to Monaco TPS dose calculations, film measurements showed enhanced dose in the prosthesis which was not predicted by Monaco due to its limitation in relative density assignment. The enhanced prosthesis dose increased with increase in beam energy and decreased with the complexity of the treatment plans, with VMAT giving the least escalated dose. The dose increased between 5% and 19% for 6 MV and between 6% and 21% for 15 MV. A gamma index analysis showed that 70-92% of dose points (excluding the prosthesis) were within 3% discrepancy. Increasing the number of treatment fields increases target dose coverage and improves the agreement between film and Monaco. When the relative electron density (RED) in the prosthesis was varied between 3.72 and 15 the dose discrepancy between film and Monaco increased from 30% to 57% for 6 MV and from 30% to 50% for 15 MV. The study indicates that beam weights for fields that pass through the prosthesis should be minimised and its RED must be correct for accurate dose calculation on Monaco.

  2. Fluorescence Analysis on the Roots of Rauvolfia Serpentina (L.) Benth. Ex Kurz Under UV Radiation

    PubMed Central

    Selvam, A.B.D; Bandyopadhyay, S.

    2005-01-01

    The present study deals with an analysis of the roots of Rauvolfia serpentine (L) Benth. Ex Kurz under ultraviolet radiation and also under daylight. The coarsely powdered roots were treated with various chemical reagents and the characteristic fluorescence patterns emitted were recorded and are reported in this paper. This study was undertaken as a pharmacognostic standardization to ascertain the authenticity of the roots of this plant in its crude form and also to check any adulteration that may be used in trade. PMID:22557172

  3. Numerical simulation of the casting process of titanium tooth crowns and bridges.

    PubMed

    Wu, M; Augthun, M; Wagner, I; Sahm, P R; Spiekermann, H

    2001-06-01

    The objectives of this paper were to simulate the casting process of titanium tooth crowns and bridges; to predict and control porosity defect. A casting simulation software, MAGMASOFT, was used. The geometry of the crowns with fine details of the occlusal surface were digitized by means of laser measuring technique, then converted and read in the simulation software. Both mold filling and solidification were simulated, the shrinkage porosity was predicted by a "feeding criterion", and the gas pore sensitivity was studied based on the mold filling and solidification simulations. Two types of dental prostheses (a single-crown casting and a three-unit-bridge) with various sprue designs were numerically "poured", and only one optimal design for each prosthesis was recommended for real casting trial. With the numerically optimized design, real titanium dental prostheses (five replicas for each) were made on a centrifugal casting machine. All the castings endured radiographic examination, and no porosity was detected in the cast prostheses. It indicates that the numerical simulation is an efficient tool for dental casting design and porosity control. Copyright 2001 Kluwer Academic Publishers

  4. In vivo bioactivity of titanium and fluorinated apatite coatings for orthopaedic implants: a vibrational study

    NASA Astrophysics Data System (ADS)

    Taddei, Paola; Tinti, Anna; Reggiani, Matteo; Monti, Patrizia; Fagnano, Concezio

    2003-06-01

    The bone integration of implants is a complex process which depends on chemical composition and surface morphology. To accelerate osteointegration, metal implants are coated with porous metal or apatites which have been reported to increase mineralisation, improving prosthesis fixation. To study the influence of composition and morphology on the in vivo bioactivity, titanium screws coated by Plasma Flame Spraying (PFS) with titanium or fluorinated apatite (K690) were implanted in sheep tibia and femur for 10 weeks and studied by micro-Raman and IR spectroscopy. The same techniques, together with thermogravimetry, were used for characterising the pre-coating K690 powder. Contrary to the manufacturer report, the K690 pre-coating revealed to be composed of a partially fluorinated apatite containing impurities of Ca(OH) 2 and CaCO 3. By effect of PFS, the impurities were decomposed and the crystallinity degree of the coating was found to decrease. The vibrational spectra recorded on the implanted screws revealed the presence of newly formed bone; for the K690-coated screws at least, a high level of osteointegration was evidenced.

  5. Improved bonding strength of bioactive cermet Cold Gas Spray coatings.

    PubMed

    Gardon, M; Concustell, A; Dosta, S; Cinca, N; Cano, I G; Guilemany, J M

    2014-12-01

    The fabrication of cermet biocompatible coatings by means Cold Gas Spray (CGS) provides prosthesis with outstanding mechanical properties and the required composition for enhancing the bioactivity of prosthetic materials. In this study, hydroxyapatite/Titanium coatings were deposited by means of CGS technology onto titanium alloy substrates with the aim of building-up well-bonded homogeneous coatings. Powders were blended in different percentages and sprayed; as long as the amount of hydroxyapatite in the feedstock increased, the quality of the coating was reduced. Besides, the relation between the particle size distribution of ceramic and metallic particles is of significant consideration. Plastic deformation of titanium particles at the impact eased the anchoring of hard hydroxyapatite particles present at the top surface of the coating, which assures the looked-for interaction with the cells. Coatings were immersed in Hank's solution for 1, 4 and 7 days; bonding strength value was above 60 MPa even after 7 days, which enhances common results of HAp coatings obtained by conventional thermal spray technologies. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. [Efficacy observation of auditory reconstruction using three different materials in ossiculoplasty and mastoidectomy to treat chronic otitis media].

    PubMed

    Gu, Xinghua; Zhu, Jing; Su, Yue

    2013-07-01

    To study the effects of different types of prosthesis used in ossiculoplasty on mastoidectomy of treating chronic otitis media. One hundred and forty three patients with chronic otitis media were treated by canal wall-down tympanoplasty with ossiculoplasty in a single stage. According to material of prosthesis, they were classified as titanium group (group A, 52 cases), hydroxypatite group (group B, 47 cases) and autogenous bone group(group C, 44 cases). The postoperative complication and hearing thresholds were analyzed in the 24 months follow-up. Average postoperative air-conduction gain and air-bone gap were measured at four frequencies: 0.5, 1.0.2, and 4.0 kHz. 12-month after operation, the average air threshold and air-bone gaps of the three groups were reduced (P < 0.05). The reconstruction successful rate (78.7%) of group A was slightly better than that of B, C (68.1%, 70.4%), there was no statistically significant difference. The difference of the average air threshold and air-bone gaps of group B, C after 24-month of operation and 12-month after operation was statistically significant (P < 0.05). The reconstruction successful rate (48.9%, 45.5%) of group B, C was lower than that of A (76.9%), the difference was also statistically significant (P < 0.05). Prostheses using titanium type could give good functional results and strong stability with low complication.

  7. [Silicate coating of cemented titanium-based shafts in hip prosthetics reduces high aseptic loosening].

    PubMed

    Marx, R; Faramarzi, R; Jungwirth, F; Kleffner, B V; Mumme, T; Weber, M; Wirtz, D C

    2009-01-01

    For cemented hip prostheses, all requirements can be fulfilled by using forged Co/Cr/Mo stems. Co/Cr/Mo alloys, however, are contraindicated for allergy sufferers. For these patients, a cemented prosthesis made of titanium (alloy) would be indicated. Cemented stems from titanium (alloy), depending on the geometry of the prosthesis and its specific surface texture, however, may have loosening rates which are clinically not tolerable. In comparison to Co/Cr/Mo alloys, the greater roughness in conjunction with lesser abrasion resistance of titanium-based alloys leads to high loosening rates caused by abrasion. On the other hand, the greater surface roughness permits good mechanical retention of bone cement to the surface. Good mechanical retention enhances migration behaviour and reduces micromotions. However, there is no stable hydrolytic bond between bone cement and metallic surface; intermediate-term debonding between metal and bone cement is predictable. This debonding results in relative movements, consequently in wear particles which have their origin both from the rough metallic surface and from the PMMA cement. The roughness of the metallic surface operates as emery and with that, a rubbing wear from the PMMA. For the above reasons, a low or moderate roughness is essential for easily abradable implants such as shafts made of titanium (alloy) because low roughness provides a fail-safe running function in case of debonding. Thus, one must allow for inappropriate migration behaviour accompanied by greater micromotions due to insufficient mechanical retention in the case of low roughness. This can be accomplished by a silicate layer coating applied to the metal shaft surface via electrochemical "ECD" or physical vapour deposition "PVD". For analysis, specimens (screws for pull-out, cones for push-out tests) were sand-blasted, so that roughnesses between Ra = 0.8 microm (Rz = 4 microm) and Ra = 2.0 microm (Rz = 9 microm) were generated. The bond strengths observed in tensile tests for roughnesses of Ra = 1.7 mm were always well above 25 MPa for all periods of hydrolytic load. Therefore, the investigation shows that surfaces of moderate roughness (Ra = 1.7 microm), however coated, provide a steady retention. Cave-in and micromotions should widely be prevented. The abrasion, which is a consequence of and reason for debonding and loosening at the same time, should be avoidable if the bonding of cement on the metallic shaft is stabilised with the help of a suitable chemical bond system.

  8. Stress distribution in fixed-partial prosthesis and peri-implant bone tissue with different framework materials and vertical misfit levels: a three-dimensional finite element analysis.

    PubMed

    Bacchi, Ataís; Consani, Rafael L X; Mesquita, Marcelo F; dos Santos, Mateus B F

    2013-09-01

    The purpose of this study was to evaluate the influence of superstructure material and vertical misfits on the stresses created in an implant-supported partial prosthesis. A three-dimensional (3-D) finite element model was prepared based on common clinical data. The posterior part of a severely resorbed jaw with two osseointegrated implants at the second premolar and second molar regions was modeled using specific modeling software (SolidWorks 2010). Finite element models were created by importing the solid model into mechanical simulation software (ANSYS Workbench 11). The models were divided into groups according to the prosthesis framework material (type IV gold alloy, silver-palladium alloy, commercially pure titanium, cobalt-chromium alloy, or zirconia) and vertical misfit level (10 µm, 50 µm, and 100 µm) created at one implant-prosthesis interface. The gap of the vertical misfit was set to be closed and the stress values were measured in the framework, porcelain veneer, retention screw, and bone tissue. Stiffer materials led to higher stress concentration in the framework and increased stress values in the retention screw, while in the same circumstances, the porcelain veneer showed lower stress values, and there was no significant difference in stress in the peri-implant bone tissue. A considerable increase in stress concentration was observed in all the structures evaluated within the misfit amplification. The framework material influenced the stress concentration in the prosthetic structures and retention screw, but not that in bone tissue. All the structures were significantly influenced by the increase in the misfit levels.

  9. Clinical outcomes of Kyocera Modular Limb Salvage system after resection of bone sarcoma of the distal part of the femur: the Japanese Musculoskeletal Oncology Group study.

    PubMed

    Nakamura, Tomoki; Matsumine, Akihiko; Uchida, Atsumasa; Kawai, Akira; Nishida, Yoshihiro; Kunisada, Toshiyuki; Araki, Nobuhito; Sugiura, Hideshi; Tomita, Masato; Yokouchi, Masahiro; Ueda, Takafumi; Sudo, Akihiro

    2014-04-01

    The Japanese Musculoskeletal Oncology Group have developed an original prosthesis called the Kyocera Modular Limb Salvage system (KMLS system). This prosthesis has a semi-rotating hinge joint and is particularly designed for people with an Asian body type. The metallic parts of the prosthesis are made entirely of titanium alloy. The purpose of this study is to evaluate the clinical outcomes of treatment using this system following tumour resection of primary bone sarcoma of the distal femur. Between 2002 and 2010, 82 patients with primary bone sarcomas of the distal femur were treated. Seventeen patients underwent stem cementation, while 65 patients were treated with cementless prostheses. The mean follow-up period after surgery was 61 months. Complications were observed in 28 of the 82 patients. Forty-one complications occurred in these 28 patients. Thirteen prostheses (16%) required revision surgery due to complications, including five cases of stem breakage, three deep infections, three cases of aseptic loosening, one case of displacement of the shaft cap and one case of breakage of the tibial tray. The five-year overall prosthetic survival rate was 80.0%. Four of the 82 patients underwent subsequent amputation due to local recurrence. The five-year limb salvage rate was 94.5%. The mean function score according to the scoring system of the Musculoskeletal Tumour Society was 21.8 points (72.5%). Although further follow-up is required to determine the performance, this prosthesis is considered to be satisfactory for reconstruction of the distal femur after resection of bone sarcoma.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wronski, M; Sarfehnia, A; Sahgal, A

    Purpose: To evaluate the interface effects when irradiating through a hip prosthesis in the presence of an orthogonal 1.5 T magnetic field using Monte Carlo simulations. Methods: A 20×20×38 cm virtual phantom with two 5×5×5 cm sections of bilateral titanium hip prosthesis was created in GPU-based Monte Carlo (MC) algorithm (GPUMCD, Elekta AB, Stockholm Sweden). The lateral prosthesis spacing was based on a representative patient CT scan. A treatment SAD of 143.5 cm was chosen, corresponding to the Elekta AB MRI Linac and the beam energy distribution was sampled from a histogram representing the true MRI Linac spectrum. A magneticmore » field of 1.5 T was applied perpendicular to the plane of irradiation. Dose was calculated, in voxels of side 1 mm, for 2×2, 5×5, and 10×10 cm treatment field sizes with normal beam incidence (gantry at 90° or 270°) and at 5° and 10° from normal, representing the range of incidence through the bilateral prosthesis. Results: With magnetic field ON (B-On) and normal beam incidence the backscatter dose at the interfaces of proximal and distal implants is reduced for all the field sizes compared to the magnetic field OFF (B-Off) case. The absolute reduction in doses at the interface was in the range of 12.93% to 13.16% for the proximal implant and 13.57% to 16.12% for the distal implant. Similarly for the oblique incidences of 5o and 10o the dose in the plane adjacent to the prosthetic implants is lower when the magnetic field is ON. Conclusion: The dosimetric effects of irradiating through a hip prosthesis in the presence of a transverse magnetic field have been determined using MC simulation. The backscatter dose reduction translates into significantly lower hot spots at the prosthetic interfaces, which are otherwise substantially high in the absence of the magnetic field. This project was supported through funding provided by ElektaTM.« less

  11. PRELOAD AND TORQUE REMOVAL EVALUATION OF THREE DIFFERENT ABUTMENT SCREWS FOR SINGLE STANDING IMPLANT RESTORATIONS

    PubMed Central

    Stüker, Rafael Augusto; Teixeira, Eduardo Rolim; Beck, João Carlos Pinheiro; da Costa, Nilza Pereira

    2008-01-01

    Several authors still consider the mechanical problems of fracture and component loosening as the main causes of failure of implant-supported restorations. The purpose of this in vitro study was to compare the preload of three types of screw for transmucosal abutment attachment used in single implant-supported prosthesis through strain gauge and removal torque measurements. Three external hex fixtures were used, and each received a transmucosal abutment (Cera One®), which was fixed to the implant with its respective screw: Group A- gold screw, Group B- titanium screw and Group C- surface-treated titanium screw (Ti-Tite®). Ten screws of each type were attached applying a 30.07±0.28 Ncm torque force and maintained in position for 5 minutes. After this, the preload values were measured using strain gauges and a measurement cell. Gold screws presented higher preload values (131.72±8.98 N), followed by surface-treated titanium screws (97.78±4.68 N) and titanium screws (37.03±5.69 N). ANOVA (p<0.05) and Tukey's test (p<0.05) were applied. Statistically significant differences were found among the groups for both preload and removal torque values. In conclusion, gold screws may be indicated to achieve superior longevity of the abutment-implant connection and, consequently, prosthetic restoration due to greater preload values yielded. PMID:19089290

  12. Simulation of the mechanical behavior of a HIP implant. Implant fixed to bone by cementation under arbitrary load

    NASA Astrophysics Data System (ADS)

    Oldani, C. R.; Dominguez, A. A.

    2007-11-01

    In a previous work a finite elements model was constructed to simulate a fatigue assay according to the norm IRAM 9422-3. Three materials were studied, two of them are the most used in this type of implant (Stainless steel 3161 and alloy T16A14V) and the third was a new developed titanium alloy (Ti35Nb7Zr5Ta). Static loads were applied to the model according to the highest requirements of the norm and the stress - strain distribution were determined. In this study a simplified analysis of the material's fatigue was done according to the previous work. The best behavior of the titanium alloys vs. the stainless steel was evident. With the objective of studying the behavior of both: the implant and the femur bone, new finite elements models were realized, in which the presence of the bone was considered. Inside the bone, the femoral component of the implant was placed in a similar way of a cemented prosthesis in a total hip arthroplasty. The advantage of the titanium implant related to the stainless steel one, was very clear.

  13. Reconstruction of an Extensive Midfacial Defect Using Additive Manufacturing Techniques.

    PubMed

    Fernandes, Nelson; van den Heever, Jacobus; Hoogendijk, Christiaan; Botha, Sarel; Booysen, Gerrie; Els, Johan

    2016-10-01

    Malignant peripheral nerve sheath tumors are extremely rare tumors arising in peripheral nerves. Only 17 cases involving the trigeminal nerve have ever been reported. These tumors have a very poor prognosis and very high rates of recurrence and metastases. Their recommended treatment involves complete tumor resection followed by radiation. This can be problematic in the head and neck region. We present a clinical case involving a 33-year-old female patient presenting with a slow-growing, exophytic mass of the anterior maxilla. Incisional biopsy and subsequent histological examination revealed a diagnosis of a malignant peripheral nerve sheath tumor. Surgical resection involved a complete maxillectomy, rhinectomy, and resection of the upper lip and aspects of the left and right cheeks. Reconstruction of the subsequent defect incorporated the placement of four zygomatic oncology implants to aid in retention of a facial prosthesis. These implants, however, were subsequently lost; and an anatomical model of the hard tissues was manufactured via 3D printing. This model was used to design and manufacture a titanium frame (customized implant) for the patient. The frame was then fixated and secured intraoperatively with 21 cortical screws. A maxillary denture and silicone facial prosthesis were also made to fit onto this frame. This is the first known case where additive manufacturing, via the use of rapid prototyping and 3D printing, was employed to manufacture a facial prosthesis. © 2016 by the American College of Prosthodontists.

  14. Simulated bone remodeling around two types of osseointegrated implants for direct fixation of upper-leg prostheses.

    PubMed

    Tomaszewski, P K; Verdonschot, N; Bulstra, S K; Rietman, J S; Verkerke, G J

    2012-11-01

    Direct attachment of an upper leg prosthesis to the skeletal system by a percutaneous implant is an alternative solution to the traditional socket fixation. In this study, we investigated long-term periprosthetic bone changes around two types of fixation implants using two different initial conditions, namely immediate post-amputation implantation and the conventional implantation after considerable time of socket prosthesis use. We questioned the difference in bone modeling response the implants provoked and if it could lead to premature bone fracture. Generic CT-based finite element models of an intact femoral bone and amputated bone implanted with models of two existing direct-fixation implants, the OPRA system (Integrum AB) and the ISP Endo/Exo prosthesis (ESKA Implants AG) were created for this study. Adaptive bone-remodeling simulations used the heel-strike and toe-off loads from a normal walking cycle. The bone loss caused by prolonged use of socket prosthesis had more severe effects on the ultimate bone quality than adaptation induced by the direct-fixation implants. Both implants showed considerable bone remodeling; the titanium screw implant (OPRA system) provoked more bone loss than the porous coated CoCrMo stem (ISP implant). The chance of the peri-prosthetic bone fracture remained higher for the post-socket case as compared to the direct amputation cases. In conclusion, both direct-fixation implants lead to considerable bone loss and bone loss is more severe after a prolonged period of post-socket use. Hence, from a biomechanical perspective it is better to limit the post-socket time and to re-design direct fixation devices to reduce bone loss and the probability of peri-prosthetic bone fractures. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Assessment of the mechanical performance of titanium cranial prostheses manufactured by super plastic forming and single point incremental forming

    NASA Astrophysics Data System (ADS)

    Sgambitterra, Emanuele; Piccininni, Antonio; Guglielmi, Pasquale; Ambrogio, Giuseppina; Fragomeni, Gionata; Villa, Tomaso; Palumbo, Gianfranco

    2018-05-01

    Cranial implants are custom prostheses characterized by quite high geometrical complexity and small thickness; at the same time aesthetic and mechanical requirements have to be met. Titanium alloys are largely adopted for such prostheses, as they can be processed via different manufacturing technologies. In the present work cranial prostheses have been manufactured by Super Plastic Forming (SPF) and Single Point Incremental Forming (SPIF). In order to assess the mechanical performance of the cranial prostheses, drop tests under different load conditions were conducted on flat samples to investigate the effect of the blank thickness. Numerical simulations were also run for comparison purposes. The mechanical performance of the cranial implants manufactured by SPF and SPIF could be predicted using drop test data and information about the thickness evolution of the formed parts: the SPIFed prosthesis revealed to have a lower maximum deflection and a higher maximum force, while the SPFed prostheses showed a lower absorbed energy.

  16. In vitro assessment of the biological response of Ti6Al4V implants coated with hydroxyapatite microdomains.

    PubMed

    Clavell, R Salvador; de Llano, J J Martín; Carda, C; Ribelles, J L Gómez; Vallés-Lluch, A

    2016-11-01

    Dental implantology is still an expanding field of scientific study because of the number of people that receive dental therapies throughout their lives worldwide. Recovery times associated to dental surgery are still long and demand strategies to improve integration of metallic devices with hard tissues. In this work, an in vitro ceramic coating is proposed to improve and accelerate osseointegration of titanium surfaces conceived to be used as dental implants or hip or knee prosthesis, shaped either as dishes or screws. Such coating consists of hydroxyapatite microdomains on the implant surfaces obtained in vitro by immersion of titanium alloy samples (Ti6Al4V) in a simulated body fluid. This titanium alloy is highly used in implant dentistry and trauma surgery, among other fields. Once the immersion times under physiological conditions yielding to different ceramic topographies on this alloy were set, the acellular coating time of major interest so as to optimize its biological development was determined. For this purpose, dental pulp mesenchymal cells were cultured on titanium coated surfaces with different hydroxyapatite outline, and cell adhesion, proliferation and morphology were followed through histological techniques and scanning electron microscopy. It was found that 4 days of acellular hydroxyapatite coating led to a significant cell adhesion on the titanium alloys at an early stage (6 h). Cells tended although to detach from the surface of the coating over time, but those adhered on domains of intricated topography or hydroxyapatite cauliflowers proliferated on them, leading to isolated large cell clusters. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 2723-2729, 2016. © 2016 Wiley Periodicals, Inc.

  17. Ear epistheses as an alternative to autogenous reconstruction.

    PubMed

    Federspil, Philipp A

    2009-08-01

    An ear episthesis is an artificial substitute for the auricle. The term EAR PROSTHESIS is used synonymously. The breakthrough came with the introduction of the modern silicones and their colorings. Although there are still indications for noninvasive methods of retention such as medical adhesives, the best and most reliable method of fixation is by bone anchorage. Long-lasting osseointegration with reaction-free skin penetration can be achieved with titanium implants. The first system used extraorally was the Brånemark flange fixture. Later, different solitary titanium implants were introduced, such as the ITI system. A different strategy used the titanium grids (Epitec) or plates (Epiplating) derived from osteosynthesis systems. These systems are fixed subperiosteally with several bone screws and are therefore also labeled as grouped implants. With these modern developments, secure retention can be achieved also in unfavorable anatomic situations. The grouped systems are resistant to torque with abutment insertion. The latest development is the subcutaneously implanted double magnet without skin penetration. The advantages of implant retained ear epistheses include optimal camouflage, predictable cosmetic results, fast rehabilitation, no donor site morbidity, and early detection of tumor recurrence. Depending on the clinical setting, prosthetic rehabilitation may be more than just an alternative to plastic reconstructive surgery. Copyright Thieme Medical Publishers.

  18. [Application of sintered Ti powder to dental prostheses].

    PubMed

    Hikosaka, Tatsuya; Tanaka, Yoshinobu; Hoshiai, Kazumoto; Kanazawa, Takeshi; Nakamura, Yoshinori; Tsuda, Kenji; Ohasi, Hideya

    2005-04-01

    Powder metallurgy is a metal processing technology. Porous titanium produced from powder is widely used. The method is applied to titanium, which is not easy to cast as it sinters under melting point. In prosthetic dentistry, powder metallurgy can be applied to high fusing metal that is biocompatible. In this study, we examined the mechanical characteristics of the Ti sheet produced by sintering and discussed its application to dental prosthesis manufacturing. Ti sheets of 1-mm thickness, in which a binder was added to spherical Ti powder, were produced with the Doctor Blade Method. The sintering was carried out between 900-1150 degrees C at 6 temperatures. The sintered compact was evaluated by dimensional change rate, hardness test, bending strength, tensile strength and SEM observation. Another compact was sintered on the refractory cast. Mechanical strength significantly increased with sintering temperature. In addition, excellent mechanical strength was acquired by adding crushed powder and performing the de-binder process. In the sintering on the refractory cast, pre-baking for more than 100 minutes and sintering at over 1050 degrees C was needed for practical application. It thus seems possible to apply sintered titanium to dental prostheses. However, it will be necessary to examine the control of the shrinkage of the sintered compact in the future too.

  19. Selection of contact bearing couple materials for hip prosthesis using finite element analysis under static conditions

    NASA Astrophysics Data System (ADS)

    Arirajan, K. A.; Chockalingam, K.; Vignesh, C.

    2018-04-01

    Implants are the artificial parts to replace the missing bones or joints in human anatomy to give mechanical support. Hip joint replacement is an important issue in orthopaedic surgery. The main concern limiting the long-run success of the total hip replacement is the limited service life. Hip replacement technique is widely used in replacing the femur head and acetabular cup by materials that are highly biocompatible. The success of the artificial hip replacement depends upon proper material selection, structure, and shape of the hip prosthesis. Many orthopaedic analyses have been tried with different materials, but ended with partial success on the application side. It is a critical task for selecting the best material pair in the hip prosthesis design. This work develops the finite element analysis of an artificial hip implant to study highest von Mises stress, contact pressure and elastic strain occurs for the dissimilar material combination. The different bearing couple considered for the analysis are Metal on Metal, Metal on Plastic, Metal on Ceramic, Ceramic on Plastic, Ceramic on Ceramic combinations. The analysis is carried out at different static positions of a human (i.e) standing, sitting. The results reveals that the combination with metal in contact with plastic (i.e) Titanium femoral head paired with Ultra High Molecular Weight Poly Ethylene acetabular cup reduces maximum von Mises stress and also it gives lowest contact pressure than other combination of bearing couples.

  20. Microstructure Evolution and Rapid Solidification Behavior of Blended Nickel-Based Superalloy Powders Fabricated by Laser Powder Deposition

    NASA Astrophysics Data System (ADS)

    Tian, Y.; Gauvin, R.; Brochu, M.

    2016-07-01

    Laser powder deposition was performed on a substrate of Inconel 738 using blended powders of Mar M247 and Amdry DF3 with a ratio of 4:1 for repairing purposes. In the as-deposited condition, continuous secondary phases composed of γ-Ni3B eutectics and discrete (Cr, W)B borides were observed in inter-dendritic regions, and time-dependent nucleation simulation results confirmed that (Cr, W)B was the primary secondary phase formed during rapid solidification. Supersaturated solid solution of B was detected in the γ solid solution dendritic cores. The Kurz-Giovanola-Trivedi model was performed to predict the interfacial morphology and correlate the solidification front velocity (SFV) with dendrite tip radius. It was observed from high-resolution scanning electron microscopy that the dendrite tip radius of the upper region was in the range of 15 to 30 nm, which yielded a SFV of approx 30 cm/s. The continuous growth model for solute trapping behavior developed by Aziz and Kaplan was used to determine that the effective partition coefficient of B was approximately 0.025. Finally, the feasibility of the modeling results were rationalized with the Clyne-Kurz segregation simulation of B, where Clyne-Kurz prediction using a partition coefficient of 0.025 was in good agreement with the electron probe microanalysis results.

  1. Tardive Dyskinesia, Oral Parafunction, and Implant-Supported Rehabilitation.

    PubMed

    Lumetti, S; Ghiacci, G; Macaluso, G M; Amore, M; Galli, C; Calciolari, E; Manfredi, E

    2016-01-01

    Oral movement disorders may lead to prosthesis and implant failure due to excessive loading. We report on an edentulous patient suffering from drug-induced tardive dyskinesia (TD) and oral parafunction (OP) rehabilitated with implant-supported screw-retained prostheses. The frequency and intensity of the movements were high, and no pharmacological intervention was possible. Moreover, the patient refused night-time splint therapy. A series of implant and prosthetic failures were experienced. Implant failures were all in the maxilla and stopped when a rigid titanium structure was placed to connect implants. Ad hoc designed studies are desirable to elucidate the mutual influence between oral movement disorders and implant-supported rehabilitation.

  2. Tardive Dyskinesia, Oral Parafunction, and Implant-Supported Rehabilitation

    PubMed Central

    Amore, M.

    2016-01-01

    Oral movement disorders may lead to prosthesis and implant failure due to excessive loading. We report on an edentulous patient suffering from drug-induced tardive dyskinesia (TD) and oral parafunction (OP) rehabilitated with implant-supported screw-retained prostheses. The frequency and intensity of the movements were high, and no pharmacological intervention was possible. Moreover, the patient refused night-time splint therapy. A series of implant and prosthetic failures were experienced. Implant failures were all in the maxilla and stopped when a rigid titanium structure was placed to connect implants. Ad hoc designed studies are desirable to elucidate the mutual influence between oral movement disorders and implant-supported rehabilitation. PMID:28050290

  3. In vitro comparative analysis of the fit of gold alloy or commercially pure titanium implant-supported prostheses before and after electroerosion.

    PubMed

    Sartori, Ivete Aparecida de Mattias; Ribeiro, Ricardo Faria; Francischone, Carlos Eduardo; de Mattos, Maria da Gloria Chiarello

    2004-08-01

    For implant-supported prostheses, passive fit is critical for the success of rehabilitation, especially when alternative materials are used. The purpose of this study was to compare interfacial fit of implant-supported prostheses cast in titanium to those cast in gold alloy. Five 3-unit fixed partial dentures were fabricated in gold alloy (Degudent U) as 1-piece castings, and 5 others were similarly cast in commercially pure titanium (Grade 1). The interfacial gaps between the prostheses and the abutments were evaluated with an optical microscope, before and after electroerosion. Readings were made with both screws tightened (10 N.cm torque), and with only 1 side tightened, so as to also evaluate the passive fit of the prostheses. Data were compared statistically by 2-way analysis of variance and the post hoc Tukey multiple range test (alpha=.05). Before electroerosion, the interfacial gaps for the 1-piece prostheses were significantly smaller (P<.001) in the gold alloy group when the screws were tightened (Au=12.6 +/- 3.0 microm, compared to Ti=30.1 +/- 6.4 microm). When the side opposite the tightened side was analyzed, there was no significant difference between the gold alloy and titanium groups (Au=69.2 +/- 24.9 microm and Ti=94.2 +/- 39.6 microm). The electroerosion procedure significantly (P<.001) reduced the gaps at the interfaces for both groups under all conditions. Comparison between groups after electroerosion did not present significant differences when the side opposite the tightened side was analyzed, but the gold alloy group showed better fit when the tightened side was analyzed (12.8 +/- 1.4 microm for gold alloy; 29.6 +/- 4.4 microm for titanium) and when both screws were tightened (5.4 +/- 2.3 microm for gold alloy; 16.1 +/- 5.5 microm for titanium). Cast titanium prostheses, despite showing larger interfacial gaps between the prosthesis and abutment than those obtained with gold alloy, had improved fit after being subjected to electroerosion.

  4. Pseudotumor Caused by Titanium Particles From a Total Hip Prosthesis.

    PubMed

    Sakamoto, Masaaki; Watanabe, Hitoshi; Higashi, Hidetaka; Kubosawa, Hitoshi

    2016-01-01

    A 77-year-old woman underwent metal-on-polyethylene total hip arthroplasty for osteoarthritis of the right hip at another institution. During surgery, the greater trochanter was broken and internal fixation was performed with a trochanteric cable grip reattachment. Although postoperative recovery was uneventful, approximately 6 years later, the patient had severe right hip pain with apparent swelling, and she was referred to the authors' institution. Plain radiographs showed evidence of severe osteolysis in the proximal femur and cable breakage; however, preoperative aspiration culture findings were negative for bacterial growth. Magnetic resonance imaging showed a well-circumscribed mass, presumed to be a pseudotumor. Serum cobalt and chromium levels were within normal limits, and the serum titanium level was high. During surgery, the mass was excised and removal of the cable system revealed a sharp deficit in the bare femoral stem. Gross surgical findings showed no obvious evidence of infection and no corrosion at the head-neck junction; therefore, all components were retained besides the cable system, which resulted in clinical recovery. All of the cultures from specimens were negative for bacterial growth, and histologic findings were compatible with a pseudotumor, such as histiocytes containing metal particles, abundant plasma cells, and CD8-positive cells. Quantitative analysis by inductively coupled plasma atomic emission spectrometry showed that the main source of metal debris in the pseudotumor was the femoral stem, which was made of titanium alloy, not the broken cable, which was made of cobalt-chromium alloy. The findings suggest that titanium particles can form symptomatic solid pseudotumors. Copyright 2016, SLACK Incorporated.

  5. Impact of intraprosthetic drilling on the strength of the femoral stem in periprosthetic fractures: A finite element investigation.

    PubMed

    Brand, Stephan; Bauer, Michael; Petri, Maximilian; Schrader, Julian; Maier, Hans J; Krettek, Christian; Hassel, Thomas

    2016-07-01

    Treatment of periprosthetic femur fractures after total hip arthroplasty remains a major challenge in orthopedic surgery. Recently, a novel surgical technique using intraprosthetic screw fixation has been suggested. The purpose of this study was to evaluate the influence of drilling the femoral hip stem on integrity and strength of the implant. The hypothesis was that intraprosthetic drilling and screw fixation would not cause the load limit of the prosthesis to be exceeded and that deformation would remain within the elastic limit. A sawbone model with a conventional straight hip stem was used and a Vancouver C periprosthetic fracture was created. The fracture was fixed with a nine-hole less invasive stabilization system plate with two screws drilled and inserted through the femoral hip stem. Three different finite element models were created using ANSYS software. The models increased in complexity including joint forces and stress risers from three different dimensions. A variation of drilling positions was analyzed. Due to the complexity of the physiological conditions in the human femur, the most complex finite element model provided the most realistic results. Overall, significant changes in the stresses to the prosthesis caused by the drilling procedure were observed. While the stresses at the site of the bore hole decreased, the load increased in the surrounding stem material. This effect is more pronounced and further the holes were apart, and it was found that increasing the number of holes could counteract this. The maximum load was still found to be in the area of the prosthesis neck. No stresses above the load limit of titanium alloy were detected. All deformations of the prosthesis stem remained in the elastic range. These results may indicate a potential role for intraprosthetic screw fixation in the future treatment of periprosthetic femur fractures. © IMechE 2016.

  6. Design Optimization and Development of Tubular Isogrid Composites Tubes for Lower Limb Prosthesis

    NASA Astrophysics Data System (ADS)

    Junqueira, Diego Morais; Gomes, Guilherme Ferreira; Silveira, Márcio Eduardo; Ancelotti, Antonio Carlos

    2018-04-01

    From the beginnings of humanity, natural or unnatural misfortunes such as illnesses, wars, automobile accidents cause loss of body limbs like teeth, arms, legs, etc. The solution found for the replacement of these missing limbs is in the use of prostheses. Lower limbs tubes or pylons are prosthetics components that are claimed to support loads during walking and other daily tasks activities. Commonly, prosthetic tubes are manufactured using metal materials such as stainless steel, aluminum and titanium. The mass of these tubes is generally high compared to tubes made of carbon fiber reinforced polymer matrix (CFRP) composite. Therefore, this work has the objective of design, manufacturing and analyzing the feasibility of a new tube concept, made of composite material, which makes use of lattice structure and inner layer. Until the present moment, lower limb prosthesis tubes using lattice structure and ineer layer have never been studied and/or tested to date. It can be stated that the tube of rigid ribs with inner layer and angle of 40° is more efficient than those of 26° and 30°. The proposed design allows a structural weight reduction in high performance prostheses from 120 g to 40 g.

  7. A Hermetic Wireless Subretinal Neurostimulator for Vision Prostheses

    PubMed Central

    Shire, Douglas B.; Chen, Jinghua; Doyle, Patrick; Gingerich, Marcus D.; Cogan, Stuart F.; Drohan, William A.; Behan, Sonny; Theogarajan, Luke; Wyatt, John L.; Rizzo, Joseph F.

    2016-01-01

    A miniaturized, hermetically encased, wirelessly operated retinal prosthesis has been developed for preclinical studies in the Yucatan minipig, and includes several design improvements over our previously reported device. The prosthesis attaches conformally to the outside of the eye and electrically drives a microfabricated thin-film polyimide array of sputtered iridium oxide film electrodes. This array is implanted into the subretinal space using a customized ab externo surgical technique. The implanted device includes a hermetic titanium case containing a 15-channel stimulator chip and discrete circuit components. Feedthroughs in the case connect the stimulator chip to secondary power and data receiving coils on the eye and to the electrode array under the retina. Long-term in vitro pulse testing of the electrodes projected a lifetime consistent with typical devices in industry. The final assembly was tested in vitro to verify wireless operation of the system in physiological saline using a custom RF transmitter and primary coils. Stimulation pulse strength, duration, and frequency were programmed wirelessly from a Peripheral Component Interconnect eXtensions for Instrumentation (PXI) computer. Operation of the retinal implant has been verified in two pigs for up to five and a half months by detecting stimulus artifacts generated by the implanted device. PMID:21859595

  8. Asymptomatic strut fracture in DeBakey-Surgitool aortic valves: incidence, management, and metallurgic aspects.

    PubMed

    Von Der Emde J, J; Eberlein, U; Breme J, J

    1990-01-01

    From August 1971 through November 1972, we implanted 62 Model 2 DeBakey-Surgitool aortic valve prostheses in 62 patients, 4 of whom later had clinically asymptomatic strut fractures. In 1 case, the patient died suddenly, and autopsy revealed detachment of the ball-cage; in each of the other 3 cases, fractures of 2 struts close to the base of the prosthesis were diagnosed fluoroscopically, and the patients underwent successful reoperation. The interval between implantation and reoperation ranged from 11 months to 16 years, 9 months. In 1 patient, retrospective study of chest radiographs revealed that the fracture had been present for 2(1/2) years. Larger valves (>/= A6) were affected significantly more often than smaller ones. We performed metallurgic analysis of 1 prosthesis: results revealed strut wear from fatigue cracking and secondary abrasion. Strut fracture was also promoted by suspension of the cage at right angles to the prosthetic ring and by use of a pyrolytic carbon ball in a titanium cage (i.e., an occluder harder than its holder). Patients with DeBakey-Surgitool aortic valve prostheses should undergo annual radiologic examinations to enable early detection of strut fractures. Prophylactic valve replacement is not indicated.

  9. Experimental and Monte Carlo evaluation of Eclipse treatment planning system for effects on dose distribution of the hip prostheses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Çatlı, Serap, E-mail: serapcatli@hotmail.com; Tanır, Güneş

    2013-10-01

    The present study aimed to investigate the effects of titanium, titanium alloy, and stainless steel hip prostheses on dose distribution based on the Monte Carlo simulation method, as well as the accuracy of the Eclipse treatment planning system (TPS) at 6 and 18 MV photon energies. In the present study the pencil beam convolution (PBC) method implemented in the Eclipse TPS was compared to the Monte Carlo method and ionization chamber measurements. The present findings show that if high-Z material is used in prosthesis, large dose changes can occur due to scattering. The variance in dose observed in the presentmore » study was dependent on material type, density, and atomic number, as well as photon energy; as photon energy increased back scattering decreased. The dose perturbation effect of hip prostheses was significant and could not be predicted accurately by the PBC method for hip prostheses. The findings show that for accurate dose calculation the Monte Carlo-based TPS should be used in patients with hip prostheses.« less

  10. Digitally Milled Metal Framework for Fixed Complete Denture with Metal Occlusal Surfaces: A Design Concept.

    PubMed

    AlBader, Bader; AlHelal, Abdulaziz; Proussaefs, Periklis; Garbacea, Antonela; Kattadiyil, Mathew T; Lozada, Jaime

    Implant-supported fixed complete dentures, often referred to as hybrid prostheses, have been associated with high implant survival rates but also with a high incidence of mechanical prosthetic complications. The most frequent of these complications have been fracture and wear of the veneering material. The proposed design concept incorporates the occlusal surfaces of the posterior teeth as part of a digital milled metal framework by designing the posterior first molars in full contour as part of the framework. The framework can be designed, scanned, and milled from a titanium blank using a milling machine. Acrylic resin teeth can then be placed on the framework by conventional protocol. The metal occlusal surfaces of the titanium-countered molars will be at centric occlusion. It is hypothesized that metal occlusal surfaces in the posterior region may reduce occlusal wear in these types of prostheses. When the proposed design protocol is followed, the connection between the metal frame and the cantilever part of the prosthesis is reinforced, which may lead to fewer fractures of the metal framework.

  11. Comparative study of new autologous material, bone-cartilage composite graft, for ossiculoplasty with Polycel® and Titanium.

    PubMed

    Kong, J S; Jeong, C Y; Shim, M J; Kim, W J; Yeo, S W; Park, S N

    2018-04-01

    Ossiculoplasty is a surgical procedure that recreates sound transmission of the middle ear in conductive hearing loss. Various materials have been used for ossicular reconstruction, but the most ideal material for ossiculoplasty remains controversial. The purpose of this study was to introduce a novel method of autologous ossiculoplasty, bone-cartilage composite graft (BCCG) and to compare its surgical results with different types of ossiculoplastic prostheses. A retrospective study was performed in a tertiary referral centre. Data of 275 patients who received ossiculoplasty using the three different materials of BCCG, Polycel ® and titanium were analysed according to type of ossiculoplasty: partial or total ossicular replacement prosthesis (PORP or TORP). Hearing results, complication rates and clinical parameters including age, sex, past history, preoperative diagnosis and surgery type were compared among different groups. Ossiculoplasty with BCCG showed satisfactory hearing outcomes and the lowest complication rate among the three different materials. In particular, its extrusion rate was 0%. We propose that the BCCG technique is a useful alternative method for ossiculoplasty, with proper patient selection. © 2017 John Wiley & Sons Ltd.

  12. Detection of fungi colony growth on bones by dynamic speckle

    NASA Astrophysics Data System (ADS)

    Vincitorio, F. M.; Budini, N.; Mulone, C.; Spector, M.; Freyre, C.; López Díaz, A. J.; Ramil, A.

    2013-11-01

    In this work we have studied the dynamic speckle patterns of mucor fungi colonies, which were inoculated on different samples. We were interested in analyzing the development of fungi colonies in bones, since during the last two years, a series of infections by mucor fungi have been reported on patients from different hospitals in Argentina. Coincidentally, all of these infections appeared on patients that were subjected to a surgical intervention for implantation of a titanium prosthesis. Apparently, the reason of the infection was a deficient sterilization process in conjunction with an accidental contamination. We observed that fungi growth, activity and death can be distinguished by means of the dynamic speckle technique.

  13. Dental implants: A review.

    PubMed

    Guillaume, B

    2016-12-01

    A high number of patients have one or more missing tooth and it is estimated that one in four American subjects over the age of 74 have lost all their natural teeth. Many options exist to replace missing teeth but dental implants have become one of the most used biomaterial to replace one (or more) missing tooth over the last decades. Contemporary dental implants made with titanium have been proven safe and effective in large series of patients. This review considers the main historical facts concerned with dental implants and present the different critical factors that will ensure a good osseo-integration that will ensure a stable prosthesis anchorage. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  14. THE INFLUENCE OF SCREW TYPE, ALLOY AND CYLINDER POSITION ON THE MARGINAL FIT OF IMPLANT FRAMEWORKS BEFORE AND AFTER LASER WELDING

    PubMed Central

    Castilio, Daniela; Pedreira, Ana Paula Ribeiro do Vale; Rossetti, Paulo Henrique Orlato; Rossetti, Leylha Maria Nunes; Bonachela, Wellington Cardoso

    2006-01-01

    Misfit at the abutment-prosthetic cylinder interface can cause loss of preload, leading to loosening or fracture of gold and titanium screws. Objectives: To evaluate the influence of screw type, alloy, and cylinder position on marginal fit of implant frameworks before and after laser welding. Methods: After Estheticone-like abutments were screwed to the implants, thirty plastic prosthetic cylinders were mounted and waxed-up to fifteen cylindrical bars. Each specimen had three interconnected prosthetic components. Five specimens were one-piece cast in titanium and five in cobalt-chromium alloy. On each specimen, tests were conducted with hexagonal titanium and slotted gold screws separately, performing a total of thirty tested screws. Measurements at the interfaces were performed using an optical microscope with 5 μm accuracy. After sectioning, specimens were laser welded and new measurements were obtained. Data were submitted to a four-way ANOVA and Tukey's multiple comparisons test (α =0.05). Results: Slotted and hexagonal screws did not present significant differences regarding to the fit of cylinders cast in titanium, either in one-piece casting framework or after laser welding. When slotted and hexagonal screws were tested on the cobalt-chromium specimens, statistically significant differences were found for the one-piece casting condition, with the slotted screws presenting better fit (24.13μm) than the hexagonal screws (27.93 μm). Besides, no statistically significant differences were found after laser welding. Conclusions: 1) The use of different metal alloys do exert influence on the marginal fit, 2) The slotted and hexagonal screws play the exclusive role of fixing the prosthesis, and did not improve the fit of cylinders, and 3) cylinder position did not affect marginal fit values. PMID:19089035

  15. Midterm Outcomes of Revision Total Hip Arthroplasty With the Use of a Multihole Highly-Porous Titanium Shell.

    PubMed

    Delanois, Ronald E; Gwam, Chukwuweike U; Mohamed, Nequesha; Khlopas, Anton; Chughtai, Morad; Malkani, Arthur L; Mont, Michael A

    2017-09-01

    We are reporting on the minimum 5-year outcomes of patients who underwent revision total hip arthroplasty (THA) using a specific highly-porous titanium shell. We assessed (1) aseptic and all-cause survivorship; (2) functional outcomes; (3) complications; and (4) radiographic outcomes. Two hospital databases were evaluated for patients who underwent revision THA due to component instability or aseptic loosening using a cementless highly-porous titanium shell between September 2006 and December 2011. This yielded 35 patients who had a mean age of 61 years (range 14-88 years). Patients had a mean follow-up of 6 years (minimum 5 years). All-cause and aseptic survivorship of the shell was calculated. Functional outcomes were assessed using the Harris Hip Score. We determined the incidence of postoperative complications and performed radiographic evaluation of pelvic radiographs from regular office visits. The aseptic survivorship of the acetabular component was 97% (95% confidence interval; 8.1-9.5). The all-cause survivorship of the acetabular component was 91% (95% confidence interval; 7.3-8.1). One patient had an aseptic failure and 2 patients had septic failures. The mean postoperative Harris Hip Score was 76 points (range, 61-91 points). Excluding the aseptic and septic failures, there was no osteolysis or progressive radiolucencies present on radiographic evaluation at final follow-up. At a minimum of 5-year follow-up, the highly-porous titanium acetabular revision shell has excellent survivorship and functional outcomes. Although long-term follow-up is needed to further monitor these implants, the results are promising and demonstrate that this prosthesis may be an excellent option for patients undergoing revision THA. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Heating of metallic implants and instruments induced by gradient switching in a 1.5-Tesla whole-body unit.

    PubMed

    Graf, Hansjörg; Steidle, Günter; Schick, Fritz

    2007-11-01

    To examine gradient switching-induced heating of metallic parts. Copper and titanium frames and sheets ( approximately 50 x 50 mm(2), 1.5 mm thick, frame width = 3 mm) surrounded by air were positioned in the scanner perpendicular to the static field horizontally 20 cm off-center. During the execution of a sequence (three-dimensional [3D] true fast imaging with steady precession [True-FISP], TR = 6.4 msec) exploiting the gradient capabilities (maximum gradient = 40 mT/m, maximum slew rate = 200 T/m/second), heating was measured with an infrared camera. Radio frequency (RF) amplitude was set to zero volts. Heating of a copper frame with a narrowing to 1 mm over 20 mm at one side was examined in air and in addition surrounded by several liters of gelled saline using fiber-optic thermography. Further heating studies were performed using an artificial hip made of titanium, and an aluminum replica of the hip prosthesis with the same geometry. For the copper specimens, considerable heating (>10 degrees C) in air and in gelled saline (>1.2 degrees C) could be observed. Heating of the titanium specimens was markedly less ( approximately 1 degrees C in air). For the titanium artificial hip no heating could be detected, while the rise in temperature for the aluminum replica was approximately 2.2 degrees C. Heating of more than 10 degrees C solely due to gradient switching without any RF irradiation was demonstrated in isolated copper wire frames. Under specific conditions (high gradient duty cycle, metallic loop of sufficient inductance and low resistance, power matching) gradient switching-induced heating of conductive specimens must be considered.

  17. The influence of screw type, alloy and cylinder position on the marginal fit of implant frameworks before and after laser welding.

    PubMed

    Castilio, Daniela; Pedreira, Ana Paula Ribeiro do Vale; Rossetti, Paulo Henrique Orlato; Rossetti, Leylha Maria Nunes; Bonachela, Wellington Cardoso

    2006-04-01

    Misfit at the abutment-prosthetic cylinder interface can cause loss of preload, leading to loosening or fracture of gold and titanium screws. To evaluate the influence of screw type, alloy, and cylinder position on marginal fit of implant frameworks before and after laser welding. After Estheticone-like abutments were screwed to the implants, thirty plastic prosthetic cylinders were mounted and waxed-up to fifteen cylindrical bars. Each specimen had three interconnected prosthetic components. Five specimens were one-piece cast in titanium and five in cobalt-chromium alloy. On each specimen, tests were conducted with hexagonal titanium and slotted gold screws separately, performing a total of thirty tested screws. Measurements at the interfaces were performed using an optical microscope with 5mm accuracy. After sectioning, specimens were laser welded and new measurements were obtained. Data were submitted to a four-way ANOVA and Tukey's multiple comparisons test (alpha=0.05). Slotted and hexagonal screws did not present significant differences regarding to the fit of cylinders cast in titanium, either in one-piece casting framework or after laser welding. When slotted and hexagonal screws were tested on the cobalt-chromium specimens, statistically significant differences were found for the one-piece casting condition, with the slotted screws presenting better fit (24.13 microm) than the hexagonal screws (27.93 microm). Besides, no statistically significant differences were found after laser welding. 1) The use of different metal alloys do exert influence on the marginal fit, 2) The slotted and hexagonal screws play the exclusive role of fixing the prosthesis, and did not improve the fit of cylinders, and 3) cylinder position did not affect marginal fit values.

  18. [Experimental study of an intratracheal stent made of shape memory alloy].

    PubMed

    Yoshimura, M; Tsugawa, C; Tsubota, N

    1994-11-01

    To develop a new prosthesis for treating tracheal stenosis and tracheobronchomalacia, we examined the usefulness of an intratracheal stent made of shape memory alloy (SMA), a titanium-nickel alloy composed of 50% of each metal. At its recovery temperature (37 degrees C), the SMA stent was designed to recall the memorized shape of a coil with a diameter of 5 or 6 mm and a length of 10 mm. For the present experiment, it was transformed to a smaller coil 3 mm in diameter at a low temperature (-50 degrees C) and then loaded into the prosthesis introducer tube. An experimental model of potentially fatal tracheomalacia was made surgically by cutting and fracturing the tracheal cartilages of rabbits and tracheal collapse was confirmed by rigid bronchoscope. The introducer tube with the SMA stent was inserted and then the prosthesis was advanced into the collapsed segment of the trachea using the stent pusher. The SMA stent warmed bo body temperature and recovered its memorized shape after 1-2 min. In 3 out of 8 rabbits, follow-up bronchoscopy performed at 6, 8, and 10 months after implantation revealed satisfactory patency of the SMA stent and the trachea. After follow-up, 3 animals were sacrificed for histological observation, which showed little proliferation of granulation tissue and no dislocation of the SMA stent from the malacic portion. The remaining 5 rabbits have been followed for 18-24 months and are doing well. We conclude that the SMA stent maintains good tracheal patency, causes little reaction in the tracheal wall, and is easy to handle. Thus, it shows the potential for clinical application.

  19. [How do metallic middle ear implants behave in the MRI?].

    PubMed

    Kwok, P; Waldeck, A; Strutz, J

    2003-01-01

    Magnetic resonance imaging (MRI) has gained in frequency and importance as a diagnostic procedure. In respect to the close anatomical relationship in the temporal bone it is necessary to know whether it is hazardous to patients with metallic middle ear implants regarding displacement and rise in temperature. For the MR image quality artefacts caused by metallic prostheses should be low. Four different stapes prostheses made from titanium, gold, teflon/platinum and teflon/steel, a titanium total ossicular reconstruction prosthesis (TORP) and two ventilation tubes (made from titanium and gold) were tested in a 1.5 Tesla MRI machine regarding their displacement. All objects were first placed in a petri dish, then suspended from a thread and finally immersed in a dish filled with Gadolinium. Temperature changes of the implants were recorded by a pyrometer. None of the implants moved when they were placed in the petri dish or suspended from the thread. On the water surface the teflon/platinum and the teflon/steel pistons adjusted their direction with their axis longitudinally to the MRI scanner opening and the teflon/steel piston floated towards the MRI-machine when put close enough to the scanner opening. No rise in temperature was recorded. All implants showed as little artefacts that would still make an evaluation of the surrounding tissue possible. Patients with any of the metallic middle ear implants that were examined in this study may undergo MRI-investigations without significant adverse effects.

  20. Advantages of microscope-integrated intraoperative online optical coherence tomography: usage in Boston keratoprosthesis type I surgery

    NASA Astrophysics Data System (ADS)

    Siebelmann, Sebastian; Steven, Philipp; Hos, Deniz; Hüttmann, Gereon; Lankenau, Eva; Bachmann, Björn; Cursiefen, Claus

    2016-01-01

    Boston keratoprosthesis (KPro) type I is a technique to treat patients with corneal diseases that are not amenable to conventional keratoplasty. Correct assembly and central implantation of the prosthesis are crucial for postoperative visual recovery. This study investigates the potential benefit of intraoperative optical coherence tomography (OCT) to monitor KPro surgery. Retrospective case series are presented for two patients who underwent Boston KPro type I implantation. The surgery in both patients was monitored intraoperatively using a commercially available intraoperative OCT (iOCT) device mounted on a surgical microscope. Microscope-integrated intraoperative OCT was able to evaluate the correct assembly and implantation of the KPro. All parts of the prosthesis were visible, and interfaces between the corneal graft and titanium backplate or anterior optics were clearly depictable. Moreover, iOCT visualized a gap between the backplate and graft in one case, and in the other case, a gap between the anterior optic and graft. Neither gap was visible with a conventional surgical microscope. The gap between the anterior optic and the graft could easily be corrected. Microscope-integrated iOCT delivers enhanced information, adding to the normal surgical microscope view during KPro surgery. Correct assembly can be controlled as well as the correct placement of the Boston KPro into the anterior chamber.

  1. [First experiences with a new nickel-titanium piston with a shape memory feature].

    PubMed

    Hornung, J; Zenk, J; Schick, B; Wurm, J; Iro, H

    2007-02-01

    The aim of this study was to describe a new stapes prosthesis with memory characteristics for wire crimping (SMart-Piston). This technique was used in 15 patients (mean age 43.4 years; range 28-71) undergoing routine stapes surgery. SMart-Piston prostheses with a shaft diameter of 0.5 mm and length ranging from 4.25-4.5 mm were used. Heat induced wire crimping was performed by CO2 laser in five patients, and by bipolar diathermy forceps in ten patients. In 15 patients, postoperative audiological testing was performed at an average 21.9 days and in another 10 again after 435 days following surgery. The median observed air-bone-gap (ABG) postoperatively was 8.7 dB+/-7.7 dB. A total of 73% of all patients had an ABG of 10 dB or less, and all patients had less than 20 dB. In the ten patients controlled after 435 days, the ABG was 4.4 dB+/-2.4 dB. It was lower than 10 dB in all individuals. A critical point in every stapes surgery, the prosthesis fixation to the incus, is greatly facilitated by this novel technique. Long-term results in a larger group of patients are pending.

  2. Influence of laser-welding and electroerosion on passive fit of implant-supported prosthesis.

    PubMed

    Silva, Tatiana Bernardon; De Arruda Nobilo, Mauro Antonio; Pessanha Henriques, Guilherme Elias; Mesquita, Marcelo Ferraz; Guimaraes, Magali Beck

    2008-01-01

    This study investigated the influence of laser welding and electroerosion procedure on the passive fit of interim fixed implant-supported titanium frameworks. Twenty frameworks were made from a master model, with five parallel placed implants in the inter foramen region, and cast in commercially pure titanium. The frameworks were divided into 4 groups: 10 samples were tested before (G1) and after (G2) electroerosion application; and another 10 were sectioned into five pieces and laser welded before (G3) and after (G4) electroerosion application. The passive fit between the UCLA abutment of the framework and the implant was evaluated using an optical microscope Olympus STM (Olympus Optical Co., Tokyo, Japan) with 0.0005mm of accuracy. Statistical analyses showed significant differences between G1 and G2, G1 and G3, G1 and G4, G2 and G4. However, no statistical difference was observed when comparing G2 and G3. These results indicate that frameworks may show a more precise adaptation if they are sectioned and laser welded. In the same way, electroerosion improves the precision in the framework adaptation.

  3. First metatarsophalangeal joint replacement with modular three-component press-fit implant. Preliminary report.

    PubMed

    Kolodziej, L; Bohatyrewicz, A; Zietek, P

    2013-01-01

    The aim of this retrospective study was to assess functional and radiographic results of the first metatarsophalangeal joint replacement with use of unconstrained, modular, three components, porous titanium and hydroxyapatite coated, press-fit METIS® prosthesis. According to author's knowledge, results of that type of prosthesis have never been published before. 25 prosthesis were implanted in 24 patients between February 2009 and May 2011. American Orthopaedic Foot and Ankle Society Hallux Metatarsophalangeal Interphalangeal scoring system (AOFAS-HMI) was used to assess functional results. Patients were also asked if they would undergo procedure again or recommend it to other people. Weight bearing radiographs ware made at final follow up and analyzed for presence of osteolysis and radiolucencies. In 8 patients total joint replacement was introduced as a salvage after failure of previous surgery like Keller resection arthroplasty, failed arthrodesis, avascular necrosis and postoperative arthritis. In 11 patients the reason for prosthetic replacement were hallux rigidus, in 4 cases rheumatoid arthritis and gout in one patient. In two patients additional procedures like Akin phalangeal osteotomy and in one case fifth metatarsal osteotomy, was performed. There were 20 females and 4 males in presented group. The mean age at the operation was 56 years. The average follow up period was 18 months (from 12 to 36 months). The median postoperative value of AOFAS-HMI scores was 88 points (from 75 to 95 points). First metatarsophalangeal joint motion (dorsiflexion plus plantarflexion) was classified according to AOFAS-HMI ranges as: moderately restricted (between 30 to 70 degrees) in 19 patients 80% (20 prosthesis) and severely restricted (less then 30 degrees) in 5 patients (20%). 15 (64%) patients were completely satisfied, 5 (20%) reported moderate satisfaction and (16%) 4 were totally disappointed and would not undergo this procedure again. A limited hallux dorsiflexion was the main dissatisfaction reason. Partial radiolucent line was seen in one patient (4%). Authors noticed two serious complications. In one patient, with rheumatoid arthritis, deep infection occurred 12 months after prosthesis implantation. In second case phalangeal implant was revised due to misalignment. METIS® metatarsophalangeal joint replacement allows alleviate of pain relating to hallux rigidus and partial restoration of joint movement, even in patients after failures of primary metatarsophalangeal joint surgery. AOFAS-HMI results are better than previously reported in the literature in assessment of the first metatarsophalangeal joint replacement. Radiographic results imply satisfactory bone ingrowth into the cementless implants.

  4. Distortion of CAD-CAM-fabricated implant-fixed titanium and zirconia complete dental prosthesis frameworks.

    PubMed

    Al-Meraikhi, Hadi; Yilmaz, Burak; McGlumphy, Edwin; Brantley, William A; Johnston, William M

    2018-01-01

    Computer-aided design and computer-aided manufacturing (CAD-CAM)-fabricated titanium and zirconia implant-supported fixed dental prostheses have become increasingly popular for restoring patients with complete edentulism. However, the distortion level of these frameworks is not well known. The purpose of this in vitro study was to compare the 3-dimensional (3D) distortion of CAD-CAM zirconia and titanium implant-fixed screw-retained complete dental prostheses. A master edentulous model with 4 implants at the positions of the maxillary first molars and canines was used. Multiunit abutments (Nobel Biocare) secured to the model were digitally scanned using scan bodies and a laboratory scanner (S600 ARTI; Zirkonzahn). Titanium (n=5) and zirconia (n=5) frameworks were milled using a CAD-CAM system (Zirkonzahn M1; Zirkonzahn). All frameworks were scanned using an industrial computed tomography (CT) scanner (Nikon/X-Tek XT H 225kV MCT Micro-Focus). The direct CT scans were reconstructed to generate standard tessellation language (STL) files. To calculate the 3D distortion of the frameworks, STL files of the CT scans were aligned to the CAD model using a sum of the least squares best-fit algorithm. Surface comparison points were placed on the CAD model on the midfacial aspect of all teeth. The 3D distortion of each direct scan to the CAD model was calculated. In addition, color maps of the scan-to-CAD comparison were constructed using a ±0.500 mm color scale range. Both materials exhibited distortion; however, no significant difference was found in the amount of distortion from the CAD model between the materials (P=.747). Absolute values of deviations from the CAD model were evident in the x and y plane and less so in the z direction. Zirconia and titanium frameworks showed similar 3D distortion compared with the CAD model for the tested CAD-CAM and implant systems. The distortion was more pronounced in the horizontal and sagittal plane than in the vertical plane. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  5. Craniofacial Prosthetic Reconstruction Using Polymethyl Methacrylate Implant: A Case Report.

    PubMed

    Simon, Paul; Mohan, Jayashree; Selvaraj, Sunantha; Saravanan, B S; Pari, Parikodaiarasan

    2014-12-01

    Large cranial defects of complex geometric shapes are challenging to reconstruct. The cranial implants has to be fabricated prior to the cranioplastic surgery. The ideal material for cranial implant has to be inert, light weight, easy to fit and adaptable to the defect, offering the best aesthetic and functional results. Here is a clinical case report of a patient who was operated for osteomyelitis in the parieto-temporal region. The defect was reconstructed with heat cure polymethylmethacrylate (PMMA). Operative closure of the defect was facilitated with ligature titanium wires with minimal prosthesis contouring. The heat cure PMMA cranial implant is a safe, easy and economic alternative with great adaptability to cranial vault defects. The cosmetic results in this patient was excellent. No post-operative complications occurred.

  6. Development and validation of segmentation and interpolation techniques in sinograms for metal artifact suppression in CT.

    PubMed

    Veldkamp, Wouter J H; Joemai, Raoul M S; van der Molen, Aart J; Geleijns, Jacob

    2010-02-01

    Metal prostheses cause artifacts in computed tomography (CT) images. The purpose of this work was to design an efficient and accurate metal segmentation in raw data to achieve artifact suppression and to improve CT image quality for patients with metal hip or shoulder prostheses. The artifact suppression technique incorporates two steps: metal object segmentation in raw data and replacement of the segmented region by new values using an interpolation scheme, followed by addition of the scaled metal signal intensity. Segmentation of metal is performed directly in sinograms, making it efficient and different from current methods that perform segmentation in reconstructed images in combination with Radon transformations. Metal signal segmentation is achieved by using a Markov random field model (MRF). Three interpolation methods are applied and investigated. To provide a proof of concept, CT data of five patients with metal implants were included in the study, as well as CT data of a PMMA phantom with Teflon, PVC, and titanium inserts. Accuracy was determined quantitatively by comparing mean Hounsfield (HU) values and standard deviation (SD) as a measure of distortion in phantom images with titanium (original and suppressed) and without titanium insert. Qualitative improvement was assessed by comparing uncorrected clinical images with artifact suppressed images. Artifacts in CT data of a phantom and five patients were automatically suppressed. The general visibility of structures clearly improved. In phantom images, the technique showed reduced SD close to the SD for the case where titanium was not inserted, indicating improved image quality. HU values in corrected images were different from expected values for all interpolation methods. Subtle differences between interpolation methods were found. The new artifact suppression design is efficient, for instance, in terms of preserving spatial resolution, as it is applied directly to original raw data. It successfully reduced artifacts in CT images of five patients and in phantom images. Sophisticated interpolation methods are needed to obtain reliable HU values close to the prosthesis.

  7. Soil carbon

    Treesearch

    Charles H. Perry; Michael C. Amacher

    2007-01-01

    Why Is Soil Carbon Important? The sequestration of carbon by forest and agricultural soils has the potential to significantly reduce greenhouse gas concentrations (Pacala and Socolow 2004). Many countries are implementing field inventories of soil carbon, often combined with data from other sources, to estimate soil carbon sequestration rates and amounts (Kurz and Apps...

  8. A classification of growth friendly spine implants.

    PubMed

    Skaggs, David L; Akbarnia, Behrooz A; Flynn, John M; Myung, Karen S; Sponseller, Paul D; Vitale, Michael G

    2014-01-01

    Various types of spinal implants have been used with the objective of minimizing spinal deformities while maximizing the spine and thoracic growth in a growing child with a spinal deformity. The aim of this study was to describe a classification system of growth friendly spinal implants to allow researchers and clinicians to have a common language and facilitate comparative studies. Growth friendly spinal implant systems fall into 3 categories based upon the forces of correction the implants exert on the spine, which are as follows: Distraction-based systems correct spinal deformities by mechanically applying a distractive force across a deformed segment with anchors at the top and bottom of the implants, which commonly attach to the spine, rib, and/or the pelvis. The present examples of distraction-based implants are spine-based or rib-based growing rods, vertical expandable titanium rib prosthesis, and remotely expandable devices. Compression-based systems correct spinal deformities with a compressive force applied to the convexity of the curve causing convex growth inhibition. This compressive force may be generated both mechanically at the time of implantation, as well as over time resulting from longitudinal growth of vertebral endplates hindered by the spinal implants. Examples of compression-based systems are vertebral staples and tethers. Guided growth systems correct spinal deformity by anchoring multiple vertebrae (usually including the apical vertebrae) to rods with mechanical forces including translation at the time of the initial implant. The majority of the anchors are not rigidly attached to the rods, thus permitting longitudinal growth over time as the anchors slide over the rods. Examples of guided growth systems include the Luque trolley and Shilla. Each system has its benefits and shortcomings. Knowledge of the fundamental principles upon which these systems are based may aid the clinician to choose an appropriate treatment for patients. Having a common language for these systems may aid in comparative research. Vertical expandable titanium rib prosthesis is used with humanitarian exemption. The other devices mentioned in this manuscript are not approved for growing constructs by the Food and Drug Administration and are used off-label.

  9. New TiAg composite coating for bone prosthesis engineering shows promising microvascular compatibility in the murine dorsal skinfold chamber model.

    PubMed

    Behrendt, Ann-Kathrin; Beythien, Maximilian; Huber, Jakob; Zufraß, Thorsten; Butschkau, Antje; Mittlmeier, Thomas; Vollmar, Brigitte

    2015-01-01

    The incorporation of antimicrobial substances like silver into implant surface coatings is one promising concept against primary infections of endoprosthesis, especially for immunocompromised patients as well as against reinfection after revision operations. However, besides good antimicrobial and mechanical properties it is equally important that the implant material does not disturb the local microvascular perfusion of muscle tissue to enable microbial host defense and tissue repair processes. In this study the biocompatibility of a newly developed TiAg-composite coating applied on conventional titanium via physical vapor deposition was analysed. To evaluate the local microvascular and inflammatory response of striated muscle tissue upon implantation of TiAg-coated plates the murine dorsal skinfold chamber model was used. We repetitively examined local capillary and venular perfusion, endothelial integrity as well as leucocyte activation by intravital fluorescence microscopy at 1 h, 24 h as well as 3 and 7 days after implantation. TiAg-implants were well tolerated by the vascular system as indicated by intact functional capillary density and endothelial integrity compared to pure titanium plates and controls without a metal implant. Furthermore, quantification of rolling and adherent leucocytes did not reveal signs of inflammation upon TiAg-implantation.

  10. Tree physiology and bark beetles

    Treesearch

    Michael G. Ryan; Gerard Sapes; Anna Sala; Sharon Hood

    2015-01-01

    Irruptive bark beetles usually co-occur with their co-evolved tree hosts at very low (endemic) population densities. However, recent droughts and higher temperatures have promoted widespread tree mortality with consequences for forest carbon, fire and ecosystem services (Kurz et al., 2008; Raffa et al., 2008; Jenkins et al., 2012). In this issue of New Phytologist,...

  11. Porous composite prosthetic pylon for integration with skin and bone

    PubMed Central

    Pitkin, Mark; Raykhtsaum, Grigory; Pilling, John; Galibin, Oleg V.; Protasov, Mikhail V.; Chihovskaya, Julie V.; Belyaeva, Irina G.; Blinova, Miralda I.; Yudintseva, Natalia M.; Potokin, Igor L.; Pinaev, George P.; Moxson, Vladimir; Duz, Volodimir

    2012-01-01

    This article presents results of the further development and testing of the “skin and bone integrated pylon” (SBIP-1) for percutaneous (through skin) connection of the residual bone with an external limb prosthesis. We investigated a composite structure (called the SBIP-2) made of titanium particles and fine wires using mathematical modeling and mechanical testing. Results showed that the strength of the pylon was comparable with that of anatomical bone. In vitro and in vivo animal studies on 30 rats showed that the reinforcement of the composite pylon did not compromise its previously shown capacity for inviting skin and bone cell ingrowth through the device. These findings provide evidence for the safe and reliable long-term percutaneous transfer of vital and therapeutic substances, signals, and necessary forces and moments from a prosthetic device to the body. PMID:17943684

  12. Influence of surgical and prosthetic techniques on marginal bone loss around titanium implants. Part I: immediate loading in fresh extraction sockets.

    PubMed

    Berberi, Antoine N; Tehini, Georges E; Noujeim, Ziad F; Khairallah, Alexandre A; Abousehlib, Moustafa N; Salameh, Ziad A

    2014-10-01

    Delayed placement of implant abutments has been associated with peri-implant marginal bone loss; however, long-term results obtained by modifying surgical and prosthetic techniques after implant placement are still lacking. This study aimed to evaluate the marginal bone loss around titanium implants placed in fresh extraction sockets using two loading protocols after a 5-year follow-up period. A total of 36 patients received 40 titanium implants (Astra Tech) intended for single-tooth replacement. Implants were immediately placed into fresh extraction sockets using either a one-stage (immediate loading by placing an interim prosthesis into functional occlusion) or a two-stage prosthetic loading protocol (insertion of abutments after 8 weeks of healing time). Marginal bone levels relative to the implant reference point were evaluated at four time intervals using intraoral radiographs: at time of implant placement, and 1, 3, and 5 years after implant placement. Measurements were obtained from mesial and distal surfaces of each implant (α = 0.05). One-stage immediate implant placement into fresh extraction sockets resulted in a significant reduction in marginal bone loss (p < 0.002) compared to the traditional two-stage technique. Whereas mesial surfaces remained stable for the 5-year observation period, significant marginal bone loss was observed on distal surfaces of implants after cementation of interim prostheses (p < 0.007) and after 12 months (p < 0.034). Within the limitations of this study, immediate loading of implants placed into fresh extraction sockets reduced marginal bone loss and did not compromise the success rate of the restorations. © 2014 by the American College of Prosthodontists.

  13. A prospective clinical study to evaluate the performance of zirconium dioxide dental implants in single-tooth gaps.

    PubMed

    Gahlert, Michael; Kniha, Heinz; Weingart, Dieter; Schild, Sabine; Gellrich, Nils-Claudius; Bormann, Kai-Hendrik

    2016-12-01

    Dental implants have traditionally been made from titanium or its alloys, but recently full-ceramic implants have been developed with comparable osseointegration properties and functional strength properties to titanium. These ceramic implants may have advantages in certain patients and situations, for example, where esthetic outcomes are particularly important. The objective of this investigation was to evaluate the performance of a newly developed full-ceramic ZrO 2 monotype implant design (PURE Ceramic Implant; Institut Straumann AG, Basel, Switzerland) in single-tooth gaps in the maxilla and mandible. This was a prospective, open-label, single-arm study in patients requiring implant rehabilitation in single-tooth gaps. Full-ceramic implants were placed, with provisional and final prostheses inserted after 3 and 6 months, respectively. Crestal bone level was measured at implant placement and after 6 and 12 months. Implant survival and success were evaluated after 6 and 12 months. Further evaluations are planned after 24 and 36 months. Forty-six patients were screened for potential study participation, of whom 44 (17 men and 27 women, mean age 48 ± 14 years) were recruited into the study. The majority of implants (90.9%) were placed in the maxilla. The implant survival and implant success rate after 12 months were 97.6%. A minor change of the mean bone level occurred between implant loading (final prosthesis insertion after 6 months) and 12 months (-0.14 mm) after initial bone remodeling was observed between implant placement and loading (-0.88 mm). The results indicated that monotype ceramic implants can achieve clinical outcomes comparable to published outcomes of equivalent titanium implants. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Pattern of External Breast Prosthesis Use by Post Mastectomy Breast Cancer Patients in India: Descriptive Study from Tertiary Care Centre.

    PubMed

    Ramu, D; Ramesh, Rakesh S; Manjunath, Suraj; Shivakumar; Goel, Vipin; Hemnath, G N; Alexander, Annie

    2015-12-01

    In India, Breast cancer is now the most common cancer in urban and 2nd most common in rural areas [1]. The incidence is rising, more younger women are getting affected and due to increase in survival rates there is an increase in the total number of women suffering from breast Cancer. So far there are no studies evaluating the pattern of breast prosthesis use in Indian scenario. The aim of this study is to address the patterns of external breast prosthesis used in India and view of Indian women on such prosthesis after mastectomy for breast cancer. This was a descriptive longitudinal study. In this study we interviewed (telephonic) 63 people, after three years of completing treatment under The Department of Surgical Oncology, St. Johns medical college, Bangalore. Among the study group, 27 members (40 %) were using various prosthesis, rest 36 women were not using any type of prosthesis. Among the users of prosthesis, silicon prosthesis was used by 6 women, padded cups by 8 women, cloth or cotton by 12 women and 1 woman used other type of prosthesis. Most women use simple items like cloth and cotton (44 %). Next most commonly used prosthesis are padded cups(). Only 22 % of women were found using silicon prosthesis in this study. Most of the well educated patients used external prosthesis either in the form of silicon prosthesis or padded cups. Most of women below age of 50 used external breast prosthesis. Use of prosthesis was more in urban compared to rural population (48 % vs 25 %). Prosthesis users worried more about the body image than women not using prosthesis. 25 % of women using prosthesis had body image issues where as only 5 % of non prosthesis users had such problems. Prosthesis users need improvement in terms of comfort, size, shape and affordability. Most common reasons for not using prosthesis are age, lack of motivation and awareness. Less than half of the women included in this study used external prosthesis after mastectomy for breast cancer. Most of the women are used home made prosthesis like cloth and cotton (44.4 %). Education, age and urban status are the strong factors which influences use of prosthesis. Prosthesis users are those who are more concerned about their body image. There is a palpable need to develop better prosthesis at affordable price.

  15. Bauhinia monandra Kurz.

    Treesearch

    K.F Connor

    2002-01-01

    Bauhinia monandra is a small fast growing, evergreen tree or shrub that commonly reaches 3 to 15.2 m in height and 0.5 m in diameter. Its smooth, gray bark can become scaly and red brown on older trees. The leaves of B. monandra are shaped like butterfly wings, rounded, and split 1/3 to 1/2 their length, forming two equal lobes...

  16. An Old-Growth Definition for Sand Pine Forests

    Treesearch

    Kenneth W. Outcalt

    1997-01-01

    Sand pine scrub, Society of American Foresters cover type 69 (Eyre 1980), grows on deep, droughty, infertile sands of marine and aeolian origin. Water and wind formed these features as sea levels fluctuated during past glacial and interglacial periods (Kurz 1942, Laessle 1958, Brooks 1972). Because of washing and sorting during transport and deposition, soil parent...

  17. [Custom-made implant for complex facial reconstruction: A case of total replacement of temporo-mandibular joint, zygomatic arch and malar bone].

    PubMed

    Guillier, D; Moris, V; See, L-A; Girodon, M; Wajszczak, B-L; Zwetyenga, N

    2017-02-01

    Total prosthetic replacement of the temporo-mandibular joint (TMJ) has become a common procedure, but it is usually limited to the TMJ itself. We report about one case of complex prosthetic joint reconstruction extending to the neighbouring bony structures. A 57-year-old patient, operated several times for a cranio-facial fibrous dysplasia, presented with a recurring TMJ ankylosis and a complexe latero-facial bone loss on the right side. We performed a reconstruction procedure including the TMJ, the zygomatic arch and the malar bone by mean of custom made composite prosthesis (chrome-cobalt-molybdenum-titanium and polyethylene). Five years postoperatively, mouth opening, nutrition, pain and oral hygiene were significantly improved. Nowadays technical possibilities allow for complex facial alloplastic reconstructions with good medium term results. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  18. Association between dental prosthesis need, nutritional status and quality of life of elderly subjects.

    PubMed

    Pillai, Rajath Sasidharan; Mathur, Vijay Prakash; Jain, Veena; Shah, Naseem; Kalra, Sandeep; Kumar, Pravesh; Dey, A B

    2015-12-01

    To determine the effect of prosthesis need on nutritional status and oral health-related quality of life (OHrQoL) in elderly and to check the disparity between prosthesis need and prosthesis want in the Indian elderly. A total of 946 geriatric participants reporting to a geriatric medicine clinic were recruited in the study. Mini-nutritional assessment (MNA), geriatric oral health assessment (GOHAI) indices, prosthesis need according to WHO criteria, and prosthesis want was recorded along with age, gender, socioeconomic status and posterior occluding pair. Significant associations exist between prosthesis need and age (p = 0.005), MNA (p = 0.006) and GOHAI (p = 0.000). Prosthesis demand too was influenced by age (p = 0.004), posterior occluding pairs (p = 0.000), MNA (p = 0.012) and GOHAI (p = 0.000). GOHAI was negatively correlated with upper (r = -0.445) and lower prosthesis need (r = -0.460). Participants with some prosthesis need had significantly lower MNA and GOHAI scores as compared to those with no prosthesis need. Though prosthesis need was high (79.7 %), demand was low (39.3 %). Prosthesis need affects nutritional status and OHrQoL in elderly, and a wide gap exists between need and want of prosthesis.

  19. Quantification and characterization of alkaloids from roots of Rauwolfia serpentina using ultra high performance liquid chromatography-photo diode array-mass spectrometry (UHPLC-PDA-MS)

    USDA-ARS?s Scientific Manuscript database

    The roots of Rauwolfia serpentina (L.) Benth. ex Kurz has been used in native Indian medicine for treatment of various illnesses and has been mainly used to treat hypertension. Reserpine is potent substance which shared both central nervous system depressant and hypotensive actions. An UHPLC-UV meth...

  20. Total flavonoids content in the raw material and aqueous extractives from Bauhinia monandra Kurz (Caesalpiniaceae).

    PubMed

    Fernandes, Ana Josane Dantas; Ferreira, Magda Rhayanny Assunção; Randau, Karina Perrelli; de Souza, Tatiane Pereira; Soares, Luiz Alberto Lira

    2012-01-01

    The aim of this work was to evaluate the spectrophotometric methodology for determining the total flavonoid content (TFC) in herbal drug and derived products from Bauhinia monandra Kurz. Several analytical parameters from this method grounded on the complex formed between flavonoids and AlCl₃ were evaluated such as herbal amount (0.25 to 1.25 g); solvent composition (ethanol 40 to 80%, v/v); as well as the reaction time and AlCl₃ concentration (2 to 9%, w/v). The method was adjusted to aqueous extractives and its performance studied through precision, linearity and preliminary robustness. The results showed an important dependence of the method response from reaction time, AlCl₃ concentration, sample amount, and solvent mixture. After choosing the optimized condition, the method was applied for the matrixes (herbal material and extractives), showing precision lower than 5% (for both parameters repeatability and intermediate precision), coefficient of determination higher than 0.99, and no important influence could be observed for slight variations from wavelength or AlCl₃ concentration. Thus, it could be concluded that the evaluated analytical procedure was suitable to quantify the total flavonoid content in raw material and aqueous extractives from leaves of B. monandra.

  1. Custom-made ocular prosthesis.

    PubMed

    Gunaseelaraj, Rajkumar; Karthikeyan, Suma; Kumar, Mohan N; Balamurugan, T; Jagadeeshwaran, A R

    2012-08-01

    An ocular defect may affect a patient psychologically. An ocular prosthesis is given to uplift the patient psychologically and improve the confidence. Ocular prosthesis can be custom made or a stock shell. To improve the comfort and matching of the prosthesis with that of the adjacent natural eye an custom made ocular prosthesis is preferred. Different techniques are available to fabricate a custom ocular prosthesis, here we have used paper iris disk technique.

  2. Experiences in the provision, fitting and supply of external breast prostheses: findings from a national survey.

    PubMed

    Gallagher, P; Buckmaster, A; O'Carroll, S; Kiernan, G; Geraghty, J

    2009-11-01

    A good-quality external breast prosthesis and prosthesis-fitting service is integral to recovery post-mastectomy. However, this area of care has minimal information or research available. The aim of this study was to investigate women's experience of the provision, fitting, supply and use of breast prostheses in Ireland. Three national surveys were undertaken with women (n = 527), breast care nurses (BCNs) (n = 32) and retail prosthesis fitters (n = 12). The findings identified the importance of the prosthesis for shape, appearance to self, appearance to others, sense of well-being, self-confidence and femininity. Dissatisfaction with weight, comfort and movement of the prosthesis was identified. Cost and travel distance were found to influence the replacement of the prosthesis. Dissatisfaction emerged with the display and choice of products, and brochure availability at the prosthesis fitting. Women preferred to be fitted for the first silicone prosthesis by a BCN in a hospital setting whereas for the replacement prosthesis they preferred a trained fitter at a specialized prosthesis supplier. BCNs and retail fitters identified the need for service guidelines and increased availability of professional development opportunities in prosthesis-fitting. These findings contributed to the development of standards of care for breast prosthesis-fitting services to benefit women and to provide guidelines for those providing the service.

  3. Predicting live and dead basal area in bark beetle-affected forests from discrete-return LiDAR

    Treesearch

    Andrew T. Hudak; Ben Bright; Jose Negron; Robert McGaughey; Hans-Erik Andersen; Jeffrey A. Hicke

    2012-01-01

    Recent bark beetle outbreaks in western North America have been widespread and severe. High tree mortality due to bark beetles affects the fundamental ecosystem processes of primary production and decomposition that largely determine carbon balance (Kurz et al. 2008, Pfeifer et al. 2011, Hicke et al. 2012). Forest managers need accurate data on beetle-induced tree...

  4. Analysis and Algorithms for Imperfect Sensor Deployment and Operations

    DTIC Science & Technology

    2016-05-23

    fortification-interdiction-routing games that take place over the traveling salesman problem (TSP) in reference 16. This study reveals that a straightforward...Journal on Optimization. 16. Lozano, L., Smith, J.C., and Kurz, M.E., Solving the Traveling Salesman Problem with Interdiction and Fortification...the Traveling Salesman Problem with Interdiction and Fortification, submitted to Operations Research Letters. Tadayon, B. and Smith, J.C., A Survey of

  5. Evaluation of an analytic linear Boltzmann transport equation solver for high-density inhomogeneities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lloyd, S. A. M.; Ansbacher, W.; Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia V8W 3P6

    2013-01-15

    Purpose: Acuros external beam (Acuros XB) is a novel dose calculation algorithm implemented through the ECLIPSE treatment planning system. The algorithm finds a deterministic solution to the linear Boltzmann transport equation, the same equation commonly solved stochastically by Monte Carlo methods. This work is an evaluation of Acuros XB, by comparison with Monte Carlo, for dose calculation applications involving high-density materials. Existing non-Monte Carlo clinical dose calculation algorithms, such as the analytic anisotropic algorithm (AAA), do not accurately model dose perturbations due to increased electron scatter within high-density volumes. Methods: Acuros XB, AAA, and EGSnrc based Monte Carlo are usedmore » to calculate dose distributions from 18 MV and 6 MV photon beams delivered to a cubic water phantom containing a rectangular high density (4.0-8.0 g/cm{sup 3}) volume at its center. The algorithms are also used to recalculate a clinical prostate treatment plan involving a unilateral hip prosthesis, originally evaluated using AAA. These results are compared graphically and numerically using gamma-index analysis. Radio-chromic film measurements are presented to augment Monte Carlo and Acuros XB dose perturbation data. Results: Using a 2% and 1 mm gamma-analysis, between 91.3% and 96.8% of Acuros XB dose voxels containing greater than 50% the normalized dose were in agreement with Monte Carlo data for virtual phantoms involving 18 MV and 6 MV photons, stainless steel and titanium alloy implants and for on-axis and oblique field delivery. A similar gamma-analysis of AAA against Monte Carlo data showed between 80.8% and 87.3% agreement. Comparing Acuros XB and AAA evaluations of a clinical prostate patient plan involving a unilateral hip prosthesis, Acuros XB showed good overall agreement with Monte Carlo while AAA underestimated dose on the upstream medial surface of the prosthesis due to electron scatter from the high-density material. Film measurements support the dose perturbations demonstrated by Monte Carlo and Acuros XB data. Conclusions: Acuros XB is shown to perform as well as Monte Carlo methods and better than existing clinical algorithms for dose calculations involving high-density volumes.« less

  6. Quantification of dental prostheses on cone‐beam CT images by the Taguchi method

    PubMed Central

    Kuo, Rong‐Fu; Fang, Kwang‐Ming; TY, Wong

    2016-01-01

    The gray values accuracy of dental cone‐beam computed tomography (CBCT) is affected by dental metal prostheses. The distortion of dental CBCT gray values could lead to inaccuracies of orthodontic and implant treatment. The aim of this study was to quantify the effect of scanning parameters and dental metal prostheses on the accuracy of dental cone‐beam computed tomography (CBCT) gray values using the Taguchi method. Eight dental model casts of an upper jaw including prostheses, and a ninth prosthesis‐free dental model cast, were scanned by two dental CBCT devices. The mean gray value of the selected circular regions of interest (ROIs) were measured using dental CBCT images of eight dental model casts and were compared with those measured from CBCT images of the prosthesis‐free dental model cast. For each image set, four consecutive slices of gingiva were selected. The seven factors (CBCTs, occlusal plane canting, implant connection, prosthesis position, coping material, coping thickness, and types of dental restoration) were used to evaluate scanning parameter and dental prostheses effects. Statistical methods of signal to noise ratio (S/N) and analysis of variance (ANOVA) with 95% confidence were applied to quantify the effects of scanning parameters and dental prostheses on dental CBCT gray values accuracy. For ROIs surrounding dental prostheses, the accuracy of CBCT gray values were affected primarily by implant connection (42%), followed by type of restoration (29%), prostheses position (19%), coping material (4%), and coping thickness (4%). For a single crown prosthesis (without support of implants) placed in dental model casts, gray value differences for ROIs 1–9 were below 12% and gray value differences for ROIs 13–18 away from prostheses were below 10%. We found the gray value differences set to be between 7% and 8% for regions next to a single implant‐supported titanium prosthesis, and between 46% and 59% for regions between double implant‐supported, nickel‐chromium alloys (Ni‐Cr) prostheses. Quantification of the effect of prostheses and scanning parameters on dental CBCT gray values was assessed. PACS numbers: 87.59.bd, 87.57Q PMID:26894354

  7. Sockets Manufactured by CAD/CAM Method Have Positive Effects on the Quality of Life of Patients With Transtibial Amputation.

    PubMed

    Karakoç, Mehmet; Batmaz, İbrahim; Sariyildiz, Mustafa Akif; Yazmalar, Levent; Aydin, Abdülkadir; Em, Serda

    2017-08-01

    Patients with amputation need prosthesis to comfortably move around. One of the most important parts of a good prosthesis is the socket. Currently, the most commonly used method is the traditional socket manufacturing method, which involves manual work; however, computer-aided design/computer-aided manufacturing (CAD/CAM) is also being used in the recent years. The present study aimed to investigate the effects of sockets manufactured by traditional and CAD/CAM method on clinical characteristics and quality of life of patients with transtibial amputation. The study included 72 patients with transtibial amputation using prosthesis, 36 of whom had CAD/CAM prosthetic sockets (group 1) and 36 had traditional prosthetic sockets (group 2). Amputation reason, prosthesis lifetime, walking time and distance with prosthesis, pain-free walking time with prosthesis, production time of the prosthesis, and adaptation time to the prosthesis were questioned. Quality of life was assessed using the 36-item Short Form Health Survey questionnaire and the Trinity Amputation and Prosthesis Experience Scales. Walking time and distance and pain-free walking time with prosthesis were significantly better in group 1 than those in group 2. Furthermore, the prosthesis was applied in a significantly shorter time, and socket adaptation time was significantly shorter in group 1. Except emotional role limitation, all 36-item Short Form Healthy Survey questionnaire parameters were significantly better in group 1 than in group 2. Trinity Amputation and Prosthesis Experience Scales activity limitation scores of group 1 were lower, and Trinity Amputation and Prosthesis Experience Scales satisfaction with the prosthesis scores were higher than those in group 2. Our study demonstrated that the sockets manufactured by CAD/CAM methods yield better outcomes in quality of life of patients with transtibial amputation than the sockets manufactured by the traditional method.

  8. Women's Satisfaction with Their Breast Prosthesis: What Determines a Quality Prosthesis?

    ERIC Educational Resources Information Center

    Livingston, Patricia M.; White, Victoria M.; Roberts, Susan B.; Pritchard, Emma; Hayman, Jane; Gibbs, Anne; Hill, David J.

    2005-01-01

    The aim of this study is to determine what factors constitute a quality prosthesis and ascertain which factors affect prosthesis satisfaction. Sixty-four women who received full funding for their prosthesis and 38 women who received their hospital's usual funding were recruited. Women rated the information provided about breast prostheses very…

  9. Penile prosthesis implant: scientific advances and technological innovations over the last four decades.

    PubMed

    Chung, Eric

    2017-02-01

    Despite introduction of oral phosphodiesterase type 5 inhibitors and intracavernosal vasoactive agents, penile prosthesis implant remains a relevant and desired option with sales of penile prostheses continue to stay high, as many men became refractory to medical therapy and/or seeking a more effective and permanent therapy. There are two types of penile prosthesis implants: inflatable and non-inflatable types, and the inflatable penile implants can be subdivided into single-, two- and three-piece devices. Non-inflatable penile prosthesis (non-IPP) may be referred to as semi-rigid rod or malleable prosthesis. IPP is considered a superior option to malleable prosthesis as it produces penile rigidity and flaccidity that closely replicates a normal penile erectile function. Since the introduction of IPP by Scott in 1973, surgical landscape for penile prosthesis implantation has changed dramatically. Advances in prosthesis design, device technologies and surgical techniques have made penile prosthesis implant a more natural, durable and reliable device. The following article reviews the scientific advances and technological innovation in modern penile prosthesis implants over the last four decades.

  10. Penile prosthesis implant: scientific advances and technological innovations over the last four decades

    PubMed Central

    2017-01-01

    Despite introduction of oral phosphodiesterase type 5 inhibitors and intracavernosal vasoactive agents, penile prosthesis implant remains a relevant and desired option with sales of penile prostheses continue to stay high, as many men became refractory to medical therapy and/or seeking a more effective and permanent therapy. There are two types of penile prosthesis implants: inflatable and non-inflatable types, and the inflatable penile implants can be subdivided into single-, two- and three-piece devices. Non-inflatable penile prosthesis (non-IPP) may be referred to as semi-rigid rod or malleable prosthesis. IPP is considered a superior option to malleable prosthesis as it produces penile rigidity and flaccidity that closely replicates a normal penile erectile function. Since the introduction of IPP by Scott in 1973, surgical landscape for penile prosthesis implantation has changed dramatically. Advances in prosthesis design, device technologies and surgical techniques have made penile prosthesis implant a more natural, durable and reliable device. The following article reviews the scientific advances and technological innovation in modern penile prosthesis implants over the last four decades. PMID:28217449

  11. Use of Powered Prosthesis for Children with Upper Limb Deficiency at Hyogo Rehabilitation Center.

    PubMed

    Toda, Mitsunori; Chin, Takaaki; Shibata, Yaeko; Mizobe, Futoshi

    2015-01-01

    There has been no research investigating the use of powered prosthetic for children in Japan. To gain better insight into the state of powered prosthesis usage and identify a ratio of rejection among children. Subjects were 37 unilateral below elbow amputees between the ages of 0 and 16 at the time of their first experienced fitting with a powered prosthesis at our Center. The information was collected from medical records and through face-to-face interviews, and we examined rejection rate and the factors affecting the use of powered prosthesis. The rate of discontinuation was 21.6% as 8 of the 37 children stopped using powered prosthesis. All of them were fitted their prosthesis after 2 years of age, and they rejected prosthesis between 5 to 19 years. We found that the level of amputation had no influence on the use of a powered prosthesis. Children fitted before 2 years of age tend to accept their powered prosthesis than those fitted after 2 years. Multidisciprinary team approach, adequate rehabilitation, detailed follow-up and involvement of parents are quite important for introducing powered prosthesis for children.

  12. Stapes surgery: how precisely do different prostheses attach to the long process of the incus with different instruments and different surgeons?

    PubMed

    Kwok, Pingling; Fisch, Ugo; Strutz, Jürgen; May, John

    2002-05-01

    The goal of this study was to compare the attachment of stapes prostheses with differently shaped loops to the long process of the incus. In stapes surgery, the attachment of the prosthesis to the long process of the incus plays an important role concerning the gain in hearing and the development of late complications such as incus erosion and necrosis. Band-shaped and spiral loops have been developed to achieve a broad, firm attachment to the long process of the incus. During stapes surgery, the view at the prosthesis is restricted, making it impossible to evaluate the effects of the differently shaped loops. Gold, steel/Teflon, platinum/Teflon, and two different titanium stapes prostheses were inserted in 30 specially prepared temporal bones by three experienced surgeons using the Fisch technique with the McGee and straight alligator forceps for the crimping of the loops. Photographs were taken with 0- and 70-degree rod lens telescopes at defined views. In all prostheses, a sufficiently firm attachment to the long process of the incus was achieved. The attachment of band-shaped loops proved to be better with the straight alligator forceps. The band-shaped loops showed a better contact with the incus than did the wire loops. However, the broad spiral-shaped loops led to a loss of the perpendicular axis of the piston to the long incus process. The geometry of the loop affects the final length of the piston in the vestibule and its angle to the long process of the incus.

  13. Prosthetic management of mid-facial defect with magnet-retained silicone prosthesis.

    PubMed

    Buzayan, Muaiyed M

    2014-02-01

    Mid-facial defect is one of the most disfiguring and impairing defects. A design of prosthesis that is aesthetic and stable can be precious to a patient who has lost part of his face due to surgical excision. Prosthesis can restore the patients' self-esteem and confidence, which affects the patients and their life style. The aim of this case report is to describe a technique of mid-facial silicone prosthesis fabrication. To provide an aesthetic and stable facial prosthesis, the extra-oral prosthesis was fabricated using silicone material, while the intra-oral defect was restored with obturator prosthesis, and then both prostheses were connected and attached to each other using magnets. This clinical report describes the rehabilitation of a large mid-facial defect with a two-piece prosthesis. The silicone facial prosthesis was made hollow and lighter by using an acrylic framework. Two acrylic channels were included within the facial prosthesis to provide the patient with clean and patent airways. A sectional mid-facial prosthesis was made and retained in place by using magnets, which resulted in a significant improvement in the aesthetical and functional outcome without the need for plastic surgery. Silicone prostheses are reliable alternatives to surgery and should be considered in selected cases.

  14. Penile Prosthesis Implantation in Patients with a History of Total Phallic Construction.

    PubMed

    Zuckerman, Jack M; Smentkowski, Katherine; Gilbert, David; Storme, Oscar; Jordan, Gerald; Virasoro, Ramon; Tonkin, Jeremy; McCammon, Kurt

    2015-12-01

    Outcomes following penile prosthesis implantation in patients with a history of total phallic construction are not well described. The aim of this study was to evaluate outcomes following neophallus penile prosthesis placement. Retrospective review penile prosthesis placement in patients with prior total phallic construction. GORE-TEX® (Gore Medical, Flagstaff, AZ) sleeve neotunica construction was utilized in all patients. Success defined as patient sexual activity with a functioning prosthesis. Thirty-one patients underwent neophallic prosthesis implantation at a mean 35.6 years of age. Prosthesis placement occurred at an average 56.3 months following phallic construction and follow-up was a mean of 59.7 months. Malleable prostheses were placed in 21 patients and inflatable in 10; implants were bilateral in 94%. Six percent experienced operative complications including a bladder injury (1) and phallic flap arterial injury (1). Postoperative complications occurred in 23% at a median 5.5 months following placement. Five prostheses were explanted secondary to infection or erosion and two additional required revisions. Of the explanted prosthesis two were later replaced without further complication. Eighty-one percent of patients were sexually active following prosthesis placement. Penile prosthesis placement is possible in patients with prior penile reconstruction/phallic construction. Although complications rates appear to be elevated in this population compared with historic controls of normal anatomic men, the majority of patients in this series were sexually active following prosthesis placement. This demonstrates the utility of prosthesis implantation in these difficult patients. © 2015 International Society for Sexual Medicine.

  15. Multivariate prediction of upper limb prosthesis acceptance or rejection.

    PubMed

    Biddiss, Elaine A; Chau, Tom T

    2008-07-01

    To develop a model for prediction of upper limb prosthesis use or rejection. A questionnaire exploring factors in prosthesis acceptance was distributed internationally to individuals with upper limb absence through community-based support groups and rehabilitation hospitals. A total of 191 participants (59 prosthesis rejecters and 132 prosthesis wearers) were included in this study. A logistic regression model, a C5.0 decision tree, and a radial basis function neural network were developed and compared in terms of sensitivity (prediction of prosthesis rejecters), specificity (prediction of prosthesis wearers), and overall cross-validation accuracy. The logistic regression and neural network provided comparable overall accuracies of approximately 84 +/- 3%, specificity of 93%, and sensitivity of 61%. Fitting time-frame emerged as the predominant predictor. Individuals fitted within two years of birth (congenital) or six months of amputation (acquired) were 16 times more likely to continue prosthesis use. To increase rates of prosthesis acceptance, clinical directives should focus on timely, client-centred fitting strategies and the development of improved prostheses and healthcare for individuals with high-level or bilateral limb absence. Multivariate analyses are useful in determining the relative importance of the many factors involved in prosthesis acceptance and rejection.

  16. Use of Powered Prosthesis for Children with Upper Limb Deficiency at Hyogo Rehabilitation Center

    PubMed Central

    Shibata, Yaeko; Mizobe, Futoshi

    2015-01-01

    Background There has been no research investigating the use of powered prosthetic for children in Japan. Objective To gain better insight into the state of powered prosthesis usage and identify a ratio of rejection among children. Methods Subjects were 37 unilateral below elbow amputees between the ages of 0 and 16 at the time of their first experienced fitting with a powered prosthesis at our Center. The information was collected from medical records and through face-to-face interviews, and we examined rejection rate and the factors affecting the use of powered prosthesis. Results The rate of discontinuation was 21.6% as 8 of the 37 children stopped using powered prosthesis. All of them were fitted their prosthesis after 2 years of age, and they rejected prosthesis between 5 to 19 years. We found that the level of amputation had no influence on the use of a powered prosthesis. Conclusions Children fitted before 2 years of age tend to accept their powered prosthesis than those fitted after 2 years. Multidisciprinary team approach, adequate rehabilitation, detailed follow-up and involvement of parents are quite important for introducing powered prosthesis for children. PMID:26125974

  17. Laser-assisted fixation of a nitinol stapes prosthesis.

    PubMed

    Schrötzlmair, Florian; Suchan, Fabian; Pongratz, Thomas; Krause, Eike; Müller, Joachim; Sroka, Ronald

    2018-02-01

    Otosclerosis is an inner ear bone disease characterized by fixation of the stapes and consequently progressive hearing loss. One treatment option is the surgical replacement of the stapes by a prosthesis. When so called "smart materials" like nitinol are used, prosthesis fixation can be performed using a laser without manual crimping on the incus. However, specific laser-prosthesis interactions have not been described yet. The aim of the present study was to elucidate the thermo-mechanical properties of the NiTiBOND® prosthesis as a basis for handling instructions for laser-assisted prosthesis fixation. Closure of the NiTiBOND® prosthesis was induced ex vivo by either a diode laser emitting at λ = 940 nm or a CO 2 laser (λ = 10,600 nm). Total energy for closure was determined. Suitable laser parameters (pulse duration, power per pulse, distance between tip of the laser fiber and prosthesis) were assessed. Specific laser-prosthesis interactions were recorded. Especially the diode laser was found to be an appropriate energy source. A total energy deposit of 60 mJ by pulses in near contact application was found to be sufficient for prosthesis closure ex vivo. Energy should be transmitted through a laser fiber equipollent to the prosthesis band diameter. Specific deformation characteristics due to the zonal prosthesis composition have to be taken into account. NiTiBOND® stapes prosthesis can be closed by very little energy when appropriate energy sources like diode lasers are used, suggesting a relatively safe application in vivo. Lasers Surg. Med. 50:153-157, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  18. The utility of 3D printing for surgical planning and patient-specific implant design for complex spinal pathologies: case report.

    PubMed

    Mobbs, Ralph J; Coughlan, Marc; Thompson, Robert; Sutterlin, Chester E; Phan, Kevin

    2017-04-01

    OBJECTIVE There has been a recent renewed interest in the use and potential applications of 3D printing in the assistance of surgical planning and the development of personalized prostheses. There have been few reports on the use of 3D printing for implants designed to be used in complex spinal surgery. METHODS The authors report 2 cases in which 3D printing was used for surgical planning as a preoperative mold, and for a custom-designed titanium prosthesis: one patient with a C-1/C-2 chordoma who underwent tumor resection and vertebral reconstruction, and another patient with a custom-designed titanium anterior fusion cage for an unusual congenital spinal deformity. RESULTS In both presented cases, the custom-designed and custom-built implants were easily slotted into position, which facilitated the surgery and shortened the procedure time, avoiding further complex reconstruction such as harvesting rib or fibular grafts and fashioning these grafts intraoperatively to fit the defect. Radiological follow-up for both cases demonstrated successful fusion at 9 and 12 months, respectively. CONCLUSIONS These cases demonstrate the feasibility of the use of 3D modeling and printing to develop personalized prostheses and can ease the difficulty of complex spinal surgery. Possible future directions of research include the combination of 3D-printed implants and biologics, as well as the development of bioceramic composites and custom implants for load-bearing purposes.

  19. Evaluation of four fast-response flow measurement devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gero, A.J.; Suppers, K.L.; Tomb, T.F.

    1988-01-01

    The Federal Mine Safety and Health Act of 1977 requires that sampling of dust in coal mine environments be conducted with an approved sampler operating at a flow rate of 2.0 liters of air per minute or at such other flow rate as prescribed by the Secretaries of Labor and of Health and Human Services. Standard procedures for calibration of these samplers within the Mine Safety and Health Administration utilize either a 3.0 liter capacity wet test meter or a 1.0 liter soap film calibrator. Several new flow calibrating devices have become commercially available. This paper describes an evaluation conductedmore » on four such devices: the Mast Model 823-2 bubble flowmeter, the Buck Calibrator, the Kurz Model 541S mass flowmeter and the Kurz Pocket Calibrator. The precision of a series of measurements made with each instrument was compared to the precision of a series of measurements made with the wet test meter. The comparison showed that the variability of calibration measurements obtained with the fast response flow calibrators was between 1.5 and 4.5 times larger than that obtained with the WTM; however, with all of the calibration devices evaluated, three repetitive measurements were sufficient to obtain a precision of {plus minus}0.1 liters per minute. 4 refs., 2 figs., 1 tab.« less

  20. Total Flavonoids Content in the Raw Material and Aqueous Extractives from Bauhinia monandra Kurz (Caesalpiniaceae)

    PubMed Central

    Fernandes, Ana Josane Dantas; Ferreira, Magda Rhayanny Assunção; Randau, Karina Perrelli; de Souza, Tatiane Pereira; Soares, Luiz Alberto Lira

    2012-01-01

    The aim of this work was to evaluate the spectrophotometric methodology for determining the total flavonoid content (TFC) in herbal drug and derived products from Bauhinia monandra Kurz. Several analytical parameters from this method grounded on the complex formed between flavonoids and AlCl3 were evaluated such as herbal amount (0.25 to 1.25 g); solvent composition (ethanol 40 to 80%, v/v); as well as the reaction time and AlCl3 concentration (2 to 9%, w/v). The method was adjusted to aqueous extractives and its performance studied through precision, linearity and preliminary robustness. The results showed an important dependence of the method response from reaction time, AlCl3 concentration, sample amount, and solvent mixture. After choosing the optimized condition, the method was applied for the matrixes (herbal material and extractives), showing precision lower than 5% (for both parameters repeatability and intermediate precision), coefficient of determination higher than 0.99, and no important influence could be observed for slight variations from wavelength or AlCl3 concentration. Thus, it could be concluded that the evaluated analytical procedure was suitable to quantify the total flavonoid content in raw material and aqueous extractives from leaves of B. monandra. PMID:22701375

  1. Complications with computer-aided designed/computer-assisted manufactured titanium and soldered gold bars for mandibular implant-overdentures: short-term observations.

    PubMed

    Katsoulis, Joannis; Wälchli, Julia; Kobel, Simone; Gholami, Hadi; Mericske-Stern, Regina

    2015-01-01

    Implant-overdentures supported by rigid bars provide stability in the edentulous atrophic mandible. However, fractures of solder joints and matrices, and loosening of screws and matrices were observed with soldered gold bars (G-bars). Computer-aided designed/computer-assisted manufactured (CAD/CAM) titanium bars (Ti-bars) may reduce technical complications due to enhanced material quality. To compare prosthetic-technical maintenance service of mandibular implant-overdentures supported by CAD/CAM Ti-bar and soldered G-bar. Edentulous patients were consecutively admitted for implant-prosthodontic treatment with a maxillary complete denture and a mandibular implant-overdenture connected to a rigid G-bar or Ti-bar. Maintenance service and problems with the implant-retention device complex and the prosthesis were recorded during minimally 3-4 years. Annual peri-implant crestal bone level changes (ΔBIC) were radiographically assessed. Data of 213 edentulous patients (mean age 68 ± 10 years), who had received a total of 477 tapered implants, were available. Ti-bar and G-bar comprised 101 and 112 patients with 231 and 246 implants, respectively. Ti-bar mostly exhibited distal bar extensions (96%) compared to 34% of G-bar (p < .001). Fracture rate of bars extensions (4.7% vs 14.8%, p < .001) and matrices (1% vs 13%, p < .001) was lower for Ti-bar. Matrices activation was required 2.4× less often in Ti-bar. ΔBIC remained stable for both groups. Implant overdentures supported by soldered gold bars or milled CAD/CAM Ti-bars are a successful treatment modality but require regular maintenance service. These short-term observations support the hypothesis that CAD/CAM Ti-bars reduce technical complications. Fracture location indicated that the titanium thickness around the screw-access hole should be increased. © 2013 Wiley Periodicals, Inc.

  2. Predictors of Receiving a Prosthesis for Adults With Above-Knee Amputations in a Well-Defined Population.

    PubMed

    Mundell, Benjamin F; Kremers, Hilal Maradit; Visscher, Sue; Hoppe, Kurtis M; Kaufman, Kenton R

    2016-08-01

    Prior studies have identified age as a factor in determining an individual's likelihood of receiving a prosthesis following a lower limb amputation. These studies are limited to specific subsets of the general population and are unable to account for preamputation characteristics within their study populations. Our study seeks to determine the effect of preamputation characteristics on the probability of receiving a prosthesis for the general population in the United States. To identify preamputation characteristics that predict of the likelihood of receiving a prosthesis following an above-knee amputation. A retrospective, population-based cohort study. Olmsted County, Minnesota (2010 population: 144,248). Individuals (n = 93) over the age of 18 years who underwent an above-knee amputation, that is, knee disarticulation or transfemoral amputation, while residing in Olmsted County, MN, between 1987 and 2013. Characteristics affecting the receipt of a prosthesis were analyzed using a logistic regression and a random forest algorithm for classification trees. Preamputation characteristics included age, gender, amputation etiology, year of amputation, mobility, cognitive ability, comorbidities, and time between surgery and the prosthesis decision. The association of preamputation characteristics with the receipt of a prosthesis following an above-knee amputation. Twenty-four of the participants received a prosthesis. The odds of receiving a prosthesis were almost 30 times higher in those able to walk independently prior to an amputation relative to those who could not walk independently. A 10-year increase in age was associated with a 53.8% decrease in the likelihood of being fit for a prosthesis (odds ratio = 0.462, P =.030). Time elapsed between surgery and the prosthesis decision was associated with a rise in probability of receiving a prosthesis for the first 3 months in the random forest algorithm. No other observed characteristics were associated with receipt of a prosthesis. The association of preamputation mobility and age with the likelihood of being fit for a prosthesis is well understood. The effect of age, after controlling for confounders, still persists and is associated with the likelihood of being fit for a prosthesis. Copyright © 2016 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  3. Robotic lower limb prosthesis design through simultaneous computer optimizations of human and prosthesis costs

    NASA Astrophysics Data System (ADS)

    Handford, Matthew L.; Srinivasan, Manoj

    2016-02-01

    Robotic lower limb prostheses can improve the quality of life for amputees. Development of such devices, currently dominated by long prototyping periods, could be sped up by predictive simulations. In contrast to some amputee simulations which track experimentally determined non-amputee walking kinematics, here, we explicitly model the human-prosthesis interaction to produce a prediction of the user’s walking kinematics. We obtain simulations of an amputee using an ankle-foot prosthesis by simultaneously optimizing human movements and prosthesis actuation, minimizing a weighted sum of human metabolic and prosthesis costs. The resulting Pareto optimal solutions predict that increasing prosthesis energy cost, decreasing prosthesis mass, and allowing asymmetric gaits all decrease human metabolic rate for a given speed and alter human kinematics. The metabolic rates increase monotonically with speed. Remarkably, by performing an analogous optimization for a non-amputee human, we predict that an amputee walking with an appropriately optimized robotic prosthesis can have a lower metabolic cost - even lower than assuming that the non-amputee’s ankle torques are cost-free.

  4. Preparation for the Implantation of an Intracortical Visual Prosthesis in a Human

    DTIC Science & Technology

    2014-10-01

    Intracortical Visual Prosthesis in a Human PRINCIPAL INVESTIGATOR: Philip R Troyk, PhD... Prosthesis in a Human 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH-12-1-0394 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Philip R Troyk...visual prosthesis (ICVP) for testing in a human. No human trial testing of the prosthesis will occur under the funded work. Preparatory tasks include

  5. Long-term role of external breast prostheses after total mastectomy.

    PubMed

    Glaus, Simone W; Carlson, Grant W

    2009-01-01

    After total mastectomy, many women choose to wear external breast prosthesis rather than undergo breast reconstruction. The purpose of this study was to evaluate long-term satisfaction among external breast prosthesis wearers and the impact of satisfaction on prosthesis use. A questionnaire was designed to assess demographic information, prosthesis information provision, prosthesis use, and satisfaction with prosthesis. Fifty-nine women who had undergone total mastectomy without breast reconstruction completed the questionnaire. The majority of women (68%) were at least 5 years out from mastectomy. Approximately half (49%) of the women had received information about breast prostheses prior to mastectomy; 29% received information from the surgeon performing the operation. Frequent and prolonged prosthesis use was prevalent with 64% of participants reporting prosthesis use all the time, 6-7 days/week. Participants showed high rates (83%) of overall satisfaction. However, women who wore their prosthesis out in public only were less satisfied than more frequent wearers (50% versus 89%, chi(2) = 8.83, d.f. = 1, alpha = 0.05). Satisfaction increased over time, as women who were greater than 5 years out from mastectomy were more satisfied than women less that 5 years post-mastectomy (90% versus 67%, chi(2) = 4.43, d.f. = 1, alpha = 0.05). The vast majority of women are satisfied with their external breast prosthesis several years after mastectomy. Most women used their prosthesis all the time and overall satisfaction contributed to higher levels of prosthesis use. Given the long-term importance of external breast prostheses for women who have undergone mastectomy, a greater effort to inform patients about external breast prostheses prior to surgery is needed.

  6. Do CTA measurements of annular diameter, perimeter and area result in different TAVI prosthesis sizes?

    PubMed

    Horehledova, Barbora; Mihl, Casper; Hendriks, Babs M F; Eijsvoogel, Nienke G; Vainer, Jindrich; Veenstra, Leo F; Wildberger, Joachim E; Das, Marco

    2018-06-16

    Incorrect prosthesis size has direct impact on patient outcome after transcatheter aortic valve implantation (TAVI) procedure. Currently, annular diameter, area or perimeter may be used for prosthesis size selection. The aim was to evaluate whether the use different annular dimensions would result in the selection of different prosthesis sizes, when assessed in the same TAVI-candidate during the same phase of a cardiac cycle. Fifty consecutive TAVI-candidates underwent retrospectively ECG-gated computed tomography angiography (CTA). Aortic root dimensions were assessed in the 20% phase of the R-R interval. Annular short diameter, perimeter and area were used to select the prosthesis size, based on the industry recommendations for a self-expandable (Medtronic CoreValve; MCV) and balloon-expandable (Edwards Sapien XT Valve; ESV) valve. Complete agreement on selected prosthesis size amongst all three annular dimensions was observed in 62% (31/50; ESV) and 30% (15/50; MCV). Short aortic annulus measurement resulted in a smaller prosthesis size in 20% (10/50; ESV) and in 60% of cases (30/50; MCV) compared to the size suggested by both annular perimeter and area. In 18% (9/50; ESV) and 10% of cases (5/50; MCV) a larger prosthesis would have been selected based on annular perimeter compared to annular diameter and area. Prosthesis size derived from area was always in agreement with at least one other parameter in all cases. Aortic annulus area appears to be the most robust parameter for TAVI-prosthesis size selection, regardless of the specific prosthesis size. Short aortic annulus diameter may underestimate the prosthesis size, while use of annular perimeter may lead to size overestimation in some cases.

  7. Permanent Quadriplegia Following Replacement of Voice Prosthesis.

    PubMed

    Ozturk, Kayhan; Erdur, Omer; Kibar, Ertugrul

    2016-11-01

    The authors presented a patient with quadriplegia caused by cervical spine abscess following voice prosthesis replacement. The authors present the first reported permanent quadriplegia patient caused by voice prosthesis replacement. The authors wanted to emphasize that life-threatening complications may be faced during the replacement of voice prosthesis. Care should be taken during the replacement of voice prosthesis and if some problems have been faced during the procedure patients must be followed closely.

  8. Preparation for the Implantation of an Intracortical Visual Prosthesis in a Human

    DTIC Science & Technology

    2013-10-01

    Intracortical Visual Prosthesis in a Human PRINCIPAL INVESTIGATOR: Philip R Troyk, PhD... Prosthesis in a Human 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH-12-1-0394 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Philip R Troyk, PhD...to prepare an intracortical visual prosthesis (ICVP) for testing in a human. No human trial testing of the prosthesis will occur under the funded

  9. Bone remodelling around HA-coated acetabular cups

    PubMed Central

    Nielsen, P. T.; Søballe, K.

    2006-01-01

    This study was designed to investigate bone remodelling around the cup in cementless THA. Previous studies indicate an advantage of better sealing of the bone-prosthesis interface by HA/TCP coating of implants, inhibiting polyethylene-induced osteolysis. One hundred patients gave informed consent to participate in a controlled randomized study between porous coated Trilogy versus Trilogy Calcicoat (HA/TCP coated). The cup was inserted in press-fit fixation. The femoral component was a cementless porous coated titanium alloy stem (Bi-Metric), with a modular 28-mm CrCo head. The Harris Hip Score (HHS) and bone mineral density (BMD) determined by DEXA scanning were used to study the effect. Measurements revealed no difference between the two groups after 3 years either in the clinical outcome or in terms of periprosthetic bone density. Patients with a body mass index above normal regained more bone mineral than patients with normal weight. This finding supports the assumption that load is beneficial to bone remodelling. PMID:16761153

  10. Abutment misfit in implant-supported prostheses manufactured by casting technique: An integrative review

    PubMed Central

    Pereira, Lorena M. S.; Sordi, Mariane B.; Magini, Ricardo S.; Calazans Duarte, Antônio R.; M. Souza, Júlio C.

    2017-01-01

    The aim of this study was to perform an integrative review of the literature on the clinically usual prosthesis-abutment misfit over implant-supported structures manufactured by conventional casting technique. The present integrative review used the PRISMA methodology. A bibliographical search was conducted on the following electronic databases: MEDLINE/PubMed (National Library of Medicine), Scopus (Elsevier), ScienceDirect (Elsevier), Web of Science (Thomson Reuters Scientific), Latin American and Caribbean Center on Health Sciences Information (BIREME), and Virtual Health Library (BVS). A total of 11 relevant studies were selected for qualitative analysis. The prosthetic-abutment vertical misfit considered clinically usual ranged from 50 to 160 μm. The vertical misfit depends on several steps during technical manufacturing techniques, which includes the materials and technical procedures. Lower values in misfit are recorded when precious metal or titanium alloys are utilized. Although a vertical misfit mean value of 100 μm has been considered clinically usual, most of the previous studies included in this revision showed lower mean values. PMID:29279686

  11. Additively manufactured sub-periosteal jaw implants.

    PubMed

    Mommaerts, M Y

    2017-07-01

    Severe bone atrophy jeopardizes the success of endosseous implants. This technical note aims to present the innovative concept of additively manufactured sub-periosteal jaw implants (AMSJIs). Digital datasets of the patient's jaws and wax trial in occlusion are used to segment the bone and dental arches, for the design of a sub-periosteal frame and abutments in the optimal location related to the dental arch and for the design of the suprastructure. The implants and suprastructure are three-dimensionally (3D) printed in titanium alloy. The provisional denture is 3D-printed in polymer. AMSJIs offer an alternative approach for patients with extreme jaw bone atrophy. This report refers to the use of this technique for full maxillary rehabilitation, but partial defects in either jaw and extended post-resection defects may also be approached using the same technique. This customized, prosthesis-driven reverse-engineering approach avoids bone grafting and provides immediate functional restoration with one surgical session. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Intermittent, noncyclic dysfunction of a mechanical aortic prosthesis by pannus formation.

    PubMed

    Giroux, Sylvie K; Labinaz, Marino X; Grisoli, Dominique; Klug, Andrew P; Veinot, John P; Burwash, Ian G

    2010-01-01

    Mechanical aortic prosthesis dysfunction can result from thrombosis or pannus formation. Pannus formation usually restricts systolic excursion of the occluding disk, resulting in progressive stenosis of the aortic prosthesis. Intermittent dysfunction of a mechanical aortic prosthesis is usually ascribed to thrombus formation. We describe an unusual case of intermittent, noncyclic dysfunction of a mechanical aortic prosthesis due to pannus formation in the absence of systolic restriction of disk excursion that presented with intermittent massive aortic regurgitation, severe ischemia, and shock. Pannus formation should be considered as a potential cause of acute intermittent severe aortic regurgitation in a patient with a mechanical aortic prosthesis.

  13. Management of long span partially edentulous maxilla with fixed removable denture prosthesis

    PubMed Central

    Jeyavalan, Mahilan I.; Narasimman, M.; Venkatakrishnan, C. J.; Philip, Jacob M.

    2012-01-01

    Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis. PMID:23293488

  14. Management of long span partially edentulous maxilla with fixed removable denture prosthesis.

    PubMed

    Jeyavalan, Mahilan I; Narasimman, M; Venkatakrishnan, C J; Philip, Jacob M

    2012-07-01

    Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis.

  15. BIORESORBABLE POLYMERIC MENISCAL PROSTHESIS: STUDY IN RABBITS

    PubMed Central

    Cardoso, Tulio Pereira; de Rezende Duek, Eliana Aparecida; Amatuzzi, Marco Martins; Caetano, Edie Benedito

    2015-01-01

    Objective: To induce growth of a neomeniscus into the pores of a prosthesis in order to protect the knee joint cartilage. Methods: 70 knees of 35 New Zealand rabbits were operated. The rabbits were five to seven months old, weighed 2 to 3.8 kilograms, and 22 were male and 13 were female. Each animal underwent medial meniscectomy in both knees during a single operation. A bioabsorbable polymeric meniscal prosthesis composed of 70% polydioxanone and 30% L-lactic acid polymer was implanted in one side. The animals were sacrificed after different postoperative time intervals. The femoral condyles and neomeniscus were subjected to histological analysis. Histograms were used to measure the degradation and absorption of the prosthesis, the growth of meniscal tissue in the prosthesis and the degree of degradation of the femoral condyle joint cartilage. Results: The data obtained showed that tissue growth histologically resembling a normal meniscus occurred, with gradual absorption of the prosthesis, and the percentages of chondrocytes on the control side and prosthesis side. Conclusion: Tissue growth into the prosthesis pores that histologically resembled the normal rabbit meniscus was observed. The joint cartilage of the femoral condyles on the prosthesis side presented greater numbers of chondrocytes in all its layers. PMID:27022549

  16. Duocentric® reversed shoulder prosthesis and Personal Fit® templates: innovative strategies to optimize prosthesis positioning and prevent scapular notching.

    PubMed

    Trouilloud, P; Gonzalvez, M; Martz, P; Charles, H; Handelberg, F; Nyffeler, R W; Baulot, E

    2014-05-01

    We describe our experience with a new system of patient-specific template called Personal Fit(®), which is unique in shoulder surgery and used in combination with Duocentric(®) prosthesis. The reverse prosthesis's concept is the invention of Paul Grammont, developed with Grammont's team of Dijon University as from 1981, which led to the first reversed total shoulder prosthesis called Trumpet in 1985. The Duocentric(®) prosthesis developed in 2001 is the third-generation prosthesis, coming from the Trumpet and the second-generation prosthesis Delta(®) (DePuy). This prosthesis provides a novel solution to the notching problem with an inferior overhang integrated onto the glenoid baseplate. Personal Fit(®) system is based on reconstructing the shoulder joint bones in three dimensions using CT scan data, placing a landmark on the scapula and locating points on the glenoid and humerus. That will be used as a reference for the patient-specific templates. We study the glenoid position planned with Personal Fit(®) software relative to native glenoid position in 30 cases. On average, the difference between the planned retroversion (or anteversion in one case) and native retroversion was 8.6°.

  17. Appendix 2: Risk-based framework and risk case studies. Risk case study: a framework for assessing climate change risks to forest carbon stocks

    Treesearch

    Christopher W. Woodall; Grant M. Domke

    2012-01-01

    Forest ecosystems have the ability to reduce the effects of climate change through the sequestration of carbon (C) (Pan et al. 2011) as well as contribute to net emissions through disturbance events such as wildfires and widespread tree mortality (Kurz et al. 2008). A conceptual framework for assessing climate-change risks to forest ecosystem C stocks facilitates...

  18. Association genetics of oleoresin flow in loblolly pine: discovering genes and predicting phenotype for improved resistance to bark beetles and bioenergy potential

    Treesearch

    Jared W. Westbrook; Marcio F. R. Resende Jr.; Patricio Munoz; Alejandro R. Walker; Jill L. Wegrzyn; C. Dana Nelson; David B. Neale; Matias Kirst; Salvador A. Gezan; Gary F. Peter; John M. Davis

    2013-01-01

    In the last decade, outbreaks of bark beetles in coniferous forests of North America have caused unprecedented tree mortality and economic losses (Nowak et al., 2008; van Mantgem et al., 2009; Waring et al., 2009), converting forests that were previously atmospheric carbon sinks into carbon sources (Kurz et al., 2008). Native species of bark beetle rapidly kill healthy...

  19. 21 CFR 888.3230 - Finger joint polymer constrained prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Finger joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3230 Finger joint polymer constrained prosthesis. (a) Identification. A finger joint polymer constrained prosthesis is a device intended...

  20. 21 CFR 888.3230 - Finger joint polymer constrained prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Finger joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3230 Finger joint polymer constrained prosthesis. (a) Identification. A finger joint polymer constrained prosthesis is a device intended...

  1. 21 CFR 888.3230 - Finger joint polymer constrained prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Finger joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3230 Finger joint polymer constrained prosthesis. (a) Identification. A finger joint polymer constrained prosthesis is a device intended...

  2. 21 CFR 888.3230 - Finger joint polymer constrained prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Finger joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3230 Finger joint polymer constrained prosthesis. (a) Identification. A finger joint polymer constrained prosthesis is a device intended...

  3. 21 CFR 888.3230 - Finger joint polymer constrained prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Finger joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3230 Finger joint polymer constrained prosthesis. (a) Identification. A finger joint polymer constrained prosthesis is a device intended...

  4. 21 CFR 872.3940 - Total temporomandibular joint prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Total temporomandibular joint prosthesis. 872.3940... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3940 Total temporomandibular joint prosthesis. (a) Identification. A total temporomandibular joint prosthesis is a device that is intended to be...

  5. 21 CFR 872.3940 - Total temporomandibular joint prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Total temporomandibular joint prosthesis. 872.3940... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3940 Total temporomandibular joint prosthesis. (a) Identification. A total temporomandibular joint prosthesis is a device that is intended to be...

  6. An innovative method of ocular prosthesis fabrication by bio-CAD and rapid 3-D printing technology: A pilot study.

    PubMed

    Alam, Md Shahid; Sugavaneswaran, M; Arumaikkannu, G; Mukherjee, Bipasha

    2017-08-01

    Ocular prosthesis is either a readymade stock shell or custom made prosthesis (CMP). Presently, there is no other technology available, which is either superior or even comparable to the conventional CMP. The present study was designed to fabricate ocular prosthesis using computer aided design (CAD) and rapid manufacturing (RM) technology and to compare it with custom made prosthesis (CMP). The ocular prosthesis prepared by CAD was compared with conventional CMP in terms of time taken for fabrication, weight, cosmesis, comfort, and motility. Two eyes of two patients were included. Computerized tomography scan of wax model of socket was converted into three dimensional format using Materialize Interactive Medical Image Control System (MIMICS)software and further refined. This was given as an input to rapid manufacturing machine (Polyjet 3-D printer). The final painting on prototype was done by an ocularist. The average effective time required for fabrication of CAD prosthesis was 2.5 hours; and weight 2.9 grams. The same for CMP were 10 hours; and 4.4 grams. CAD prosthesis was more comfortable for both the patients. The study demonstrates the first ever attempt of fabricating a complete ocular prosthesis using CAD and rapid manufacturing and comparing it with conventional CMP. This prosthesis takes lesser time for fabrication, and is more comfortable. Studies with larger sample size will be required to further validate this technique.

  7. In vitro biomechanical analysis of torque capabilities of various 0.018″ lingual bracket-wire systems: total torque play and slot size.

    PubMed

    Daratsianos, Nikolaos; Bourauel, Christoph; Fimmers, Rolf; Jäger, Andreas; Schwestka-Polly, Rainer

    2016-10-01

    To determine the total torque play of various rectangular titanium molybdenum alloy (TMA)/stainless steel (SS) wires in various 0.018″ upper incisor lingual brackets and slot size measurements. TMA (0.0175″ × 0.0175″, 0.0170″ × 0.025″, 0.0182″ × 0.0182″, 0.0182″ × 0.025″) and SS wires (0.016″ × 0.022″, 0.016″ × 0.024″, 0.018″ × 0.025″) were twisted in standard (Hiro, Incognito™, Joy®, Kurz 7th generation, STb™: fixation with elastic modules) and self-ligating brackets (Evolution SLT®, In-Ovation® L MTM: closed ligation mechanism) from -20 degrees to +20 degrees with a custom-made machine. The total torque play was calculated by extrapolating the linear portion of the twist/moment curves to the x-axis and adding the absolute negative and positive angle values at the intercepts. The bracket slot height was measured before and after the experiments with a series of pin gauges with round profile. Brackets in ascending order for total torque play with the most slot-filling wire TMA 0.0182″ × 0.025″: Evolution SLT® (0 degree ± 0 degree), Incognito™ (2.2 degrees ±1.1 degrees), Hiro (5.1 degrees ±3.0 degrees), In-Ovation® L MTM (6.3 degrees ±2.2 degrees), STb™ (6.6 degrees ±1.8 degrees), Kurz 7th generation (7.1 degrees ±0.8 degrees), and Joy® (12.0 degrees ±0.8 degrees). Wires in ascending order for total torque play with the most precise slot Incognito™: TMA 0.0182″ × 0.025″ (2.2 degrees ±1.1 degrees), TMA 0.0182″ × 0.0182″ (2.4 degrees ±0.9 degrees), SS 0.018″ × 0.025″ (5.5 degrees ±1.0 degrees), TMA 0.0170″ × 0.025″ (9.4 degrees ±1.8 degrees), TMA 0.0175″ × 0.0175″ (13.0 degrees ±1.5 degrees), SS 0.016″ × 0.024″ (16.1 degrees ±1.4 degrees), SS 0.016″ × 0.022″ (17.8 degrees ±1.0 degrees); differences between some of the experimental groups were not statistically significant. Bracket slot dimensions in ascending order: Evolution SLT® (less than 0.452mm), Incognito™ (0.460mm ±0.002mm), In-Ovation® L MTM (0.469mm ±0.001mm), Hiro (0.469mm ±0.010mm), STb™ (0.471mm ±0.002mm), Kurz 7th generation (0.473mm ±0.002mm), and Joy® (greater than 0.498mm). The applied method must be questioned when used with brackets with incomplete slot walls (Evolution SLT®). Slot measurement with pin gauges may not register bracket wing deformation. All brackets showed a differing slot size from the nominal 0.018″ (0.457mm). Incognito™ presented the most precise and Joy® the widest slot. The main wires for the retraction phase SS 0.016″ × 0.022″/SS 0.016″ × 0.024″ showed poor torque control. Among the finishing TMA wires, TMA 0.0175″ × 0.0175″ exhibited the highest and TMA 0.0182″ × 0.0182″/TMA 0.0182″ × 0.025″ the smallest torque play. The manufacturers could profit from this investigation towards optimization of the dimensional precision of their products. The orthodontist must be aware of the torque play of the wire-bracket combinations to be able to plan and individualize the appliance by third order customization. © The Author 2015. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  8. Artificial limb representation in amputees

    PubMed Central

    van den Heiligenberg, Fiona M Z; Orlov, Tanya; Macdonald, Scott N; Duff, Eugene P; Henderson Slater, David; Beckmann, Christian F; Johansen-Berg, Heidi; Culham, Jody C; Makin, Tamar R

    2018-01-01

    Abstract The human brain contains multiple hand-selective areas, in both the sensorimotor and visual systems. Could our brain repurpose neural resources, originally developed for supporting hand function, to represent and control artificial limbs? We studied individuals with congenital or acquired hand-loss (hereafter one-handers) using functional MRI. We show that the more one-handers use an artificial limb (prosthesis) in their everyday life, the stronger visual hand-selective areas in the lateral occipitotemporal cortex respond to prosthesis images. This was found even when one-handers were presented with images of active prostheses that share the functionality of the hand but not necessarily its visual features (e.g. a ‘hook’ prosthesis). Further, we show that daily prosthesis usage determines large-scale inter-network communication across hand-selective areas. This was demonstrated by increased resting state functional connectivity between visual and sensorimotor hand-selective areas, proportional to the intensiveness of everyday prosthesis usage. Further analysis revealed a 3-fold coupling between prosthesis activity, visuomotor connectivity and usage, suggesting a possible role for the motor system in shaping use-dependent representation in visual hand-selective areas, and/or vice versa. Moreover, able-bodied control participants who routinely observe prosthesis usage (albeit less intensively than the prosthesis users) showed significantly weaker associations between degree of prosthesis observation and visual cortex activity or connectivity. Together, our findings suggest that altered daily motor behaviour facilitates prosthesis-related visual processing and shapes communication across hand-selective areas. This neurophysiological substrate for prosthesis embodiment may inspire rehabilitation approaches to improve usage of existing substitutionary devices and aid implementation of future assistive and augmentative technologies. PMID:29534154

  9. Artificial limb representation in amputees.

    PubMed

    van den Heiligenberg, Fiona M Z; Orlov, Tanya; Macdonald, Scott N; Duff, Eugene P; Henderson Slater, David; Beckmann, Christian F; Johansen-Berg, Heidi; Culham, Jody C; Makin, Tamar R

    2018-05-01

    The human brain contains multiple hand-selective areas, in both the sensorimotor and visual systems. Could our brain repurpose neural resources, originally developed for supporting hand function, to represent and control artificial limbs? We studied individuals with congenital or acquired hand-loss (hereafter one-handers) using functional MRI. We show that the more one-handers use an artificial limb (prosthesis) in their everyday life, the stronger visual hand-selective areas in the lateral occipitotemporal cortex respond to prosthesis images. This was found even when one-handers were presented with images of active prostheses that share the functionality of the hand but not necessarily its visual features (e.g. a 'hook' prosthesis). Further, we show that daily prosthesis usage determines large-scale inter-network communication across hand-selective areas. This was demonstrated by increased resting state functional connectivity between visual and sensorimotor hand-selective areas, proportional to the intensiveness of everyday prosthesis usage. Further analysis revealed a 3-fold coupling between prosthesis activity, visuomotor connectivity and usage, suggesting a possible role for the motor system in shaping use-dependent representation in visual hand-selective areas, and/or vice versa. Moreover, able-bodied control participants who routinely observe prosthesis usage (albeit less intensively than the prosthesis users) showed significantly weaker associations between degree of prosthesis observation and visual cortex activity or connectivity. Together, our findings suggest that altered daily motor behaviour facilitates prosthesis-related visual processing and shapes communication across hand-selective areas. This neurophysiological substrate for prosthesis embodiment may inspire rehabilitation approaches to improve usage of existing substitutionary devices and aid implementation of future assistive and augmentative technologies.

  10. 21 CFR 888.3790 - Wrist joint metal constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint metal constrained cemented prosthesis... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3790 Wrist joint metal constrained cemented prosthesis. (a) Identification. A wrist joint metal constrained cemented prosthesis is a...

  11. 21 CFR 888.3790 - Wrist joint metal constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint metal constrained cemented prosthesis... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3790 Wrist joint metal constrained cemented prosthesis. (a) Identification. A wrist joint metal constrained cemented prosthesis is a...

  12. 21 CFR 888.3720 - Toe joint polymer constrained prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Toe joint polymer constrained prosthesis. 888.3720... (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3720 Toe joint polymer constrained prosthesis. (a) Identification. A toe joint polymer constrained prosthesis is a device made of silicone...

  13. 21 CFR 888.3780 - Wrist joint polymer constrained prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3780 Wrist joint polymer constrained prosthesis. (a) Identification. A wrist joint polymer constrained prosthesis is a device made of...

  14. 21 CFR 888.3720 - Toe joint polymer constrained prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Toe joint polymer constrained prosthesis. 888.3720... (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3720 Toe joint polymer constrained prosthesis. (a) Identification. A toe joint polymer constrained prosthesis is a device made of silicone...

  15. 21 CFR 888.3780 - Wrist joint polymer constrained prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3780 Wrist joint polymer constrained prosthesis. (a) Identification. A wrist joint polymer constrained prosthesis is a device made of...

  16. 21 CFR 888.3780 - Wrist joint polymer constrained prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wrist joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3780 Wrist joint polymer constrained prosthesis. (a) Identification. A wrist joint polymer constrained prosthesis is a device made of...

  17. 21 CFR 888.3780 - Wrist joint polymer constrained prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wrist joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3780 Wrist joint polymer constrained prosthesis. (a) Identification. A wrist joint polymer constrained prosthesis is a device made of...

  18. 21 CFR 888.3720 - Toe joint polymer constrained prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Toe joint polymer constrained prosthesis. 888.3720... (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3720 Toe joint polymer constrained prosthesis. (a) Identification. A toe joint polymer constrained prosthesis is a device made of silicone...

  19. 21 CFR 888.3720 - Toe joint polymer constrained prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Toe joint polymer constrained prosthesis. 888.3720... (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3720 Toe joint polymer constrained prosthesis. (a) Identification. A toe joint polymer constrained prosthesis is a device made of silicone...

  20. 21 CFR 888.3780 - Wrist joint polymer constrained prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wrist joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3780 Wrist joint polymer constrained prosthesis. (a) Identification. A wrist joint polymer constrained prosthesis is a device made of...

  1. 21 CFR 888.3720 - Toe joint polymer constrained prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Toe joint polymer constrained prosthesis. 888.3720... (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3720 Toe joint polymer constrained prosthesis. (a) Identification. A toe joint polymer constrained prosthesis is a device made of silicone...

  2. 21 CFR 872.3960 - Mandibular condyle prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3960 Mandibular condyle prosthesis. (a) Identification. A mandibular condyle prosthesis is a device that is intended to be implanted in the human jaw to... requirement for premarket approval for any mandibular condyle prosthesis intended to be implanted in the human...

  3. 21 CFR 888.3025 - Passive tendon prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Passive tendon prosthesis. 888.3025 Section 888...) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3025 Passive tendon prosthesis. (a) Identification. A passive tendon prosthesis is a device intended to be implanted made of silicon elastomer or a...

  4. 21 CFR 888.3025 - Passive tendon prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Passive tendon prosthesis. 888.3025 Section 888...) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3025 Passive tendon prosthesis. (a) Identification. A passive tendon prosthesis is a device intended to be implanted made of silicon elastomer or a...

  5. Reverse Shoulder Arthroplasty Prosthesis Design Classification System.

    PubMed

    Routman, Howard D; Flurin, Pierre-Henri; Wright, Thomas W; Zuckerman, Joseph D; Hamilton, Matthew A; Roche, Christopher P

    2015-12-01

    Multiple different reverse total shoulder arthroplasty (rTSA) prosthesis designs are available in the global marketplace for surgeons to perform this growing procedure. Subtle differences in rTSA prosthesis design parameters have been shown to have significant biomechanical impact and clinical consequences. We propose an rTSA prosthesis design classification system to objectively identify and categorize different designs based upon their specific glenoid and humeral prosthetic characteristics for the purpose of standardizing nomenclature that will help the orthopaedic surgeon determine which combination of design configurations best suit a given clinical scenario. The impact of each prosthesis classification type on shoulder muscle length and deltoid wrapping are also described to illustrate how each prosthesis classification type impacts these biomechanical parameters.

  6. Development and clinical application of a new testicular prosthesis

    PubMed Central

    Ning, Ye; Cai, Zhikang; Chen, Huixing; Ping, Ping; Li, Peng; Wang, Zhong; Li, Zheng

    2011-01-01

    A new type of testicular prosthesis made of silastic with an elliptical shape to mimic a normal testis was developed by our team and submitted for patenting in China. The prosthesis was produced in different sizes to imitate the normal testis of the patient. To investigate the effects and safety of the testicular prosthesis, 20 patients receiving testicular prosthesis implantation were recruited for this study. Follow-up after 6 months revealed no complications in the patients. All the patients answered that they were satisfied with their body image and the position of the implants, 19 patients were satisfied with the size and 16 patients were satisfied with the weight. These results show that the testicular prosthesis used in this study can meet patient's expectations. Patients undergoing orchiectomy should be offered the option to receive a testicular prosthesis implantation. The dimensions and weight of the available prosthetic implants should be further addressed to improve patient satisfaction. PMID:21927041

  7. Manufacturer-provided effective orifice area index charts and the prevention of prosthesis-patient mismatch.

    PubMed

    House, Chad M; Nelson, William B; Kroshus, Timothy J; Dahiya, Ranjan; Pibarot, Philippe

    2012-01-01

    Prosthesis-patient mismatch (PPM) occurs when an implanted prosthesis is too small relative to the patient's body surface area (BSA). However, mismatch can often be prevented by indexing the expected effective orifice area (EOA) of a prosthesis to the patient's BSA and then selecting the largest implantable prosthesis to avoid mismatch. Previously, prosthesis manufacturers have attempted to simplify this process by providing charts that include the expected EOA for their prosthesis, already indexed into an array of BSA values. One caveat with these charts is that the expected EOA data must truly be reliable, or the charts will misguide the implanting surgeon. Manufacturer-provided charts could be improved by standardizing the EOA data, with one potential source being the hemodynamic data submitted to the United States Food and Drug Administration. This review discusses PPM, manufacturer-provided EOA charts, and the regulation of EOA data.

  8. Experimental and numerical study on optimization of the single point incremental forming of AINSI 304L stainless steel sheet

    NASA Astrophysics Data System (ADS)

    Saidi, B.; Giraud-Moreau, L.; Cherouat, A.; Nasri, R.

    2017-09-01

    AINSI 304L stainless steel sheets are commonly formed into a variety of shapes for applications in the industrial, architectural, transportation and automobile fields, it’s also used for manufacturing of denture base. In the field of dentistry, there is a need for personalized devises that are custom made for the patient. The single point incremental forming process is highly promising in this area for manufacturing of denture base. The single point incremental forming process (ISF) is an emerging process based on the use of a spherical tool, which is moved along CNC controlled tool path. One of the major advantages of this process is the ability to program several punch trajectories on the same machine in order to obtain different shapes. Several applications of this process exist in the medical field for the manufacturing of personalized titanium prosthesis (cranial plate, knee prosthesis...) due to the need of product customization to each patient. The objective of this paper is to study the incremental forming of AISI 304L stainless steel sheets for future applications in the dentistry field. During the incremental forming process, considerable forces can occur. The control of the forming force is particularly important to ensure the safe use of the CNC milling machine and preserve the tooling and machinery. In this paper, the effect of four different process parameters on the maximum force is studied. The proposed approach consists in using an experimental design based on experimental results. An analysis of variance was conducted with ANOVA to find the input parameters allowing to minimize the maximum forming force. A numerical simulation of the incremental forming process is performed with the optimal input process parameters. Numerical results are compared with the experimental ones.

  9. High rate of osteolytic lesions in medium-term followup after the AES total ankle replacement.

    PubMed

    Kokkonen, Ari; Ikävalko, Mikko; Tiihonen, Raine; Kautiainen, Hannu; Belt, Eero A

    2011-02-01

    Some previous studies have shown a high percentage of early-onset and rapidly progressing osteolysis associated with total ankle arthroplasty (TAA) by the Ankle Evolutive System (AES). The purpose of our study was to analyze medium-term results at our institution. Altogether 38 TAAs using AES prostheses were carried out between 2003 and 2007. Diagnoses were rheumatoid arthritis (71%), post-traumatic and idiopathic osteoarthritis (29%). The mean age was 54 years, followup 28 months. Tibial and talar components had hydroxyapatite coating on metal (Co-Cr) components (HA-coated). Since 2005 the design was changed and components were porous coated with titanium and hydroxyapatite (dual-coated). Two-year survival was 79% (95% CI: 56 to 98). At followup 34 (89%) primary tibial and talar components were preserved. In 19 (50%) TAAs osteolysis (more than or equal to 2 mm) occurred in the periprosthetic bone area and in nine (24%) comprised large "cyst-like osteolysis''. In HA-coated prostheses radiolucent lines (less than or equal to 2 mm) or osteolysis (more than or equal to 2 mm) were detected in 11 (100%) cases and in dual-coated prostheses in 19 (74%) (p = 0.08). On the other hand there was more large "cyst-like osteolysis'' around the dual-coated prosthesis and lesions were larger (p = 0.017). In rheumatoid arthritis osteolysis was detected in 14 (52%) and large "cyst-like osteolysis'' in seven (26%) prostheses and in the group of traumatic and idiopathic osteoarthritis in six (55%) and two (18%), respectively. This study showed a high frequency of osteolysis in medium-term followup after the AES ankle replacement. The outcome was not sufficiently beneficial and we have discontinued use of this prosthesis.

  10. Comparison of three-implant-supported fixed dentures and two-implant-retained overdentures in the edentulous mandible: a pilot study of treatment efficacy and patient satisfaction.

    PubMed

    De Kok, Ingeborg J; Chang, Kuang-Han; Lu, Tsui-Shan; Cooper, Lyndon F

    2011-01-01

    The mandibular two-implant overdenture has been shown to be a highly successful treatment. However, overdenture patients who desire a fixed prosthesis may not be satisfied with a removable overdenture. This prospective study sought to compare prosthetic outcomes, patient satisfaction, and survival rates of implants between two-implant-supported overdentures (IODs) and three-implant-supported fixed dentures (ISFDs). Twenty completely edentulous patients were randomly and equally assigned to two groups. New conventional complete dentures were made, and the mandibular denture was used as a surgical guide during implant placement. Implants were placed in one stage, followed by a mandibular denture soft reline (provisional loading). Ball attachments were inserted at 8 weeks, and ISFDs were delivered at 16 weeks. IODs were connected to the attachments at 8 weeks, using each patients's existing denture. The definitive ISFDs were fabricated using computer-aided design/computer-assisted manufacture milled titanium frameworks and acrylic resin base and teeth. Patient satisfaction and panoramic radiographs were investigated at 6 and 12 months. Both treatments had significant and positive effects on patient satisfaction and quality of life. None of the 50 implants placed had failed at 12 months of follow-up; therefore, the implant survival rate was 100%. Prosthetic complications were generally rare and easily manageable. Both the treatment modalities-the ISFD supported by three implants and the IOD supported by two implants-significantly and similarly improved patient satisfaction and oral health-related quality of life, and prosthetic complications were relatively rare for both treatments. Three implants can be used to support a mandibular fixed prosthesis; however, a longer observation period is needed to validate this treatment modality.

  11. 21 CFR 888.3730 - Toe joint phalangeal (hemi-toe) polymer prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Toe joint phalangeal (hemi-toe) polymer prosthesis. 888.3730 Section 888.3730 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-toe) polymer prosthesis. (a) Identification. A toe joint phalangeal (hemi-toe) polymer prosthesis...

  12. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  13. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  14. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  15. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  16. 21 CFR 888.3730 - Toe joint phalangeal (hemi-toe) polymer prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Toe joint phalangeal (hemi-toe) polymer prosthesis. 888.3730 Section 888.3730 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-toe) polymer prosthesis. (a) Identification. A toe joint phalangeal (hemi-toe) polymer prosthesis...

  17. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  18. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  19. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  20. 21 CFR 888.3730 - Toe joint phalangeal (hemi-toe) polymer prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Toe joint phalangeal (hemi-toe) polymer prosthesis. 888.3730 Section 888.3730 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-toe) polymer prosthesis. (a) Identification. A toe joint phalangeal (hemi-toe) polymer prosthesis...

  1. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  2. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  3. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  4. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  5. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  6. 21 CFR 888.3730 - Toe joint phalangeal (hemi-toe) polymer prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Toe joint phalangeal (hemi-toe) polymer prosthesis. 888.3730 Section 888.3730 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-toe) polymer prosthesis. (a) Identification. A toe joint phalangeal (hemi-toe) polymer prosthesis...

  7. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  8. 21 CFR 888.3730 - Toe joint phalangeal (hemi-toe) polymer prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Toe joint phalangeal (hemi-toe) polymer prosthesis. 888.3730 Section 888.3730 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-toe) polymer prosthesis. (a) Identification. A toe joint phalangeal (hemi-toe) polymer prosthesis...

  9. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  10. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  11. Prosthesis rejection in acquired major upper-limb amputees: a population-based survey.

    PubMed

    Østlie, Kristin; Lesjø, Ingrid Marie; Franklin, Rosemary Joy; Garfelt, Beate; Skjeldal, Ola Hunsbeth; Magnus, Per

    2012-07-01

    To estimate the rates of primary and secondary prosthesis rejection in acquired major upper-limb amputees (ULAs), to describe the most frequently reported reasons for rejection and to estimate the influence of background factors on the risk of rejection. Cross-sectional study analysing population-based questionnaire data (n = 224). Effects were analysed by logistic regression analyses and Cox regression analyses. Primary prosthesis rejection was found in 4.5% whereas 13.4% had discontinued prosthesis use. The main reasons reported for primary non-wear were a perceived lack of need and discrepancies between perceived need and the prostheses available. The main reasons reported for secondary prosthesis rejection were dissatisfaction with prosthetic comfort, function and control. Primary prosthesis rejection was more likely in ULAs amputated at high age and in ULAs with proximal amputations. Secondary prosthesis rejection was more likely in proximal ULAs and in women. Clinicians should be aware of the increased risk of rejection in proximal ULAs, elderly ULAs and in women. Emphasising individual needs will probably facilitate successful prosthetic fitting. Improved prosthesis quality and individualised prosthetic training may increase long-term prosthesis use. Further studies of the effect of prosthetic training and of the reasons for rejection of different prosthetic types are suggested.

  12. Novel knee joint mechanism of transfemoral prosthesis for stair ascent.

    PubMed

    Inoue, Koh; Wada, Takahiro; Harada, Ryuchi; Tachiwana, Shinichi

    2013-06-01

    The stability of a transfemoral prosthesis when walking on flat ground has been established by recent advances in knee joint mechanisms and their control methods. It is, however, difficult for users of a transfemoral prosthesis to ascend stairs. This difficulty is mainly due to insufficient generation of extension moment around the knee joint of the prosthesis to lift the body to the next step on the staircase and prevent any unexpected flexion of the knee joint in the stance phase. Only a prosthesis with an actuator has facilitated stair ascent using a step-over-step gait (1 foot is placed per step). However, its use has issues associated with the durability, cost, maintenance, and usage environment. Therefore, the purpose of this research is to develop a novel knee joint mechanism for a prosthesis that generates an extension moment around the knee joint in the stance phase during stair ascent, without the use of any actuators. The proposed mechanism is based on the knowledge that the ground reaction force increases during the stance phase when the knee flexion occurs. Stair ascent experiments with the prosthesis showed that the proposed prosthesis can realize stair ascent without any undesirable knee flexion. In addition, the prosthesis is able to generate a positive knee joint moment power in the stance phase even without any power source.

  13. BIOENERGETIC DIFFERENCES DURING WALKING AND RUNNING IN TRANSFEMORAL AMPUTEE RUNNERS USING ARTICULATING AND NON-ARTICULATING KNEE PROSTHESES

    PubMed Central

    Highsmith, M. Jason; Kahle, Jason T.; Miro, Rebecca M.; Mengelkoch, Larry J.

    2016-01-01

    Transfemoral amputation (TFA) patients require considerably more energy to walk and run than non-amputees. The purpose of this study was to examine potential bioenergetic differences (oxygen uptake (VO2), heart rate (HR), and ratings of perceived exertion (RPE)) for TFA patients utilizing a conventional running prosthesis with an articulating knee mechanism versus a running prosthesis with a non-articulating knee joint. Four trained TFA runners (n = 4) were accommodated to and tested with both conditions. VO2 and HR were significantly lower (p ≤ 0.05) in five of eight fixed walking and running speeds for the prosthesis with an articulating knee mechanism. TFA demonstrated a trend for lower RPE at six of eight walking speeds using the prosthesis with the articulated knee condition. A trend was observed for self-selected walking speed, self-selected running speed, and maximal speed to be faster for TFA subjects using the prosthesis with the articulated knee condition. Finally, all four TFA participants subjectively preferred running with the prosthesis with the articulated knee condition. These findings suggest that, for trained TFA runners, a running prosthesis with an articulating knee prosthesis reduces ambulatory energy costs and enhances subjective perceptive measures compared to using a non-articulating knee prosthesis. PMID:28066524

  14. Postpneumonectomy syndrome in children: advantages and long-term follow-up of expandable prosthesis.

    PubMed

    Podevin, G; Larroquet, M; Camby, C; Audry, G; Plattner, V; Heloury, Y

    2001-09-01

    Pneumonectomy in children can be complicated by a severe mediastinal shift, which leads to bronchial stretching resulting in severe respiratory failure. This postpneumonectomy syndrome can be corrected by inserting a prosthesis in the empty side of the chest. Forty-two children, from 6 months to 15 years old, underwent a pneumonectomy. Seven of these patients were treated surgically for severe manifestations of postpneumonectomy syndrome. First insertion of an expandable prosthesis was followed up in 5 cases by its replacement with a breast prosthesis in adolescence. The expandable prosthesis was injected periodically with saline solution to maintain the mediastinum in a midline position as the children grew. The mean delay between pneumonectomy and first prosthesis implantation was 5 years (range, 11 months to 8 years). Pulmonary function tests showed a substantial improvement in the obstructive syndrome in all patients except one, in whom the functional improvement was moderate. The mean follow-up after the expandable prosthesis implantation was 6 years (range, 6 months to 10 years) and all patients are doing well. The insertion of an intrathoracic prosthesis can dramatically improve the clinical symptoms and reduce the functional obstructive syndrome. The expandable prosthesis allowed for progressive, well-tolerated recentering of the mediastinum and adjustment for growth. Copyright 2001 by W.B. Saunders Company.

  15. Malrotation of the McGhan Style 510 prosthesis.

    PubMed

    Schots, Jeroen M P; Fechner, Maarten R; Hoogbergen, Maarten M; van Tits, Herm W H J

    2010-07-01

    Anatomically shaped cohesive silicone breast implants are frequently used in aesthetic and reconstructive surgery. After successful results with the Style 410 prosthesis, McGhan (Natrelle, Allergan) introduced the Style 510 prosthesis. After using this novel prosthesis, the authors encountered a high number of prosthesis malrotations on self-reported follow-up. Therefore, a retrospective medical record review was performed to determine the prevalence of malrotation of the Style 510 prosthesis. From January of 2005 to December of 2006, 73 (146 prostheses) aesthetic augmentation mammaplasty procedures were performed using Style 510 prostheses. All prostheses were placed subglandularly through an inframammary incision. The postsurgical protocol for the first 3 weeks involved wearing a nonwired compression bra, abstinence from sports activities, and abstinence from heavy labor. Standard follow-up was at 1 week, 3 months, and if necessary. On self-reported follow-up, 8.2 percent of all prostheses were rotated. These rotations all occurred unilaterally after a mean period of 10 months (range, 3 to 19 months). No relation to an inciting incident or prosthesis volume could be found. The number of rotations of the Style 510 prosthesis seen after primary aesthetic breast augmentation is high. An obvious cause of this major problem has not been found. This led the authors to discontinue using the Style 510 prosthesis for primary aesthetic mammary augmentations in their practice.

  16. Biomechanical evaluation of two types of short-stemmed hip prostheses compared to the trust plate prosthesis by three-dimensional measurement of micromotions.

    PubMed

    Fottner, Andreas; Schmid, Markus; Birkenmaier, Christof; Mazoochian, Farhad; Plitz, Wolfgang; Volkmar, Jansson

    2009-06-01

    Stemless and short-stemmed hip prostheses have been developed to preserve femoral bone stock. While all these prostheses claim a more or less physiological load transfer, clinical long-term results are only available for the stemless thrust plate prosthesis. In this study, the in vitro primary stability of the thrust plate prosthesis was compared to two types of short-stemmed prostheses. In addition to the well-established Mayo prosthesis, the modular Metha prosthesis was tested using cone adapters with 130 degrees and 140 degrees neck-shaft-angles. The prostheses were implanted in composite femurs and loaded dynamically (300-1700 N). Three-dimensional micromotions at the bone-prosthesis interface were measured. In addition, the three-dimensional deformations at the surface of the composite femur were measured to gain data on the strain distribution. For all tested prostheses, the micromotions did not exceed 150 microm, the critical value for osteointegration. The thrust plate prosthesis revealed similar motions as the short-stemmed prostheses. The short-stemmed prosthesis with the 130 degrees cone tended to have the highest micromotions of all tested short-stemmed prostheses. The thrust plate prosthesis revealed the lowest alteration of bone surface deformation after implantation. The comparably low micromotions of the thrust plate prosthesis and the short-stemmed prostheses should be conducive to osseous integration. The higher alteration of load transmission after implantation reveals a higher risk of stress shielding for the short-stemmed prostheses.

  17. Can We Improve the Tolerance of an Ocular Prosthesis by Enhancing Its Surface Finish?

    PubMed

    Litwin, Andre S; Worrell, Emma; Roos, Jonathan C P; Edwards, Barry; Malhotra, Raman

    Patients who wear an ocular prosthesis frequently suffer with dry eye symptoms and socket discharge, often on a daily basis. The aim of the study was to determine whether a smoother, optical quality polish of the prosthesis' surface could improve symptoms and wear tolerance. The study was designed as single-center, single-masked, prospective randomized controlled trial. Eighty-eight consecutive patients undergoing annual ocular prosthesis maintenance review were approached from the prosthesis clinic. Forty-one out of 49 eligible patients were recruited. Participants were randomized to either a standard or a higher "optical quality" polish of their prosthesis. At entry to the trial, at 1 month, and 12 months they completed a questionnaire covering cleaning, lubricant use, inflammation, discomfort, and discharge. Lower scores indicated better tolerance of the prosthesis. At each visit, the prosthesis was stained and photographed against a standard background to assess deposit build up. Primary outcome measures were 1) a subjective questionnaire score and 2) an objective assessment of surface deposit build-up on prosthetic eyes by standardized photographic grading. Forty-one patients participated in the study. The median age of their prosthesis was 36 months (range 9 months-40 years). There was no statistically significant difference in questionnaire scores or deposit build up between the 2 groups at baseline. By 12-months, the higher optical quality polish showed a statistically significant reduction in symptoms and frequency of discharge (2.19 vs. 3.85; p = 0.05-lower scores better). Scoring of the prosthesis' deposit build-up showed a significant difference at 1 month, but this was not sustained at 12 months. Creating an optical quality finish to an ocular prosthesis reduces deposit build up on artificial eyes. The authors found this modification improved patient tolerance at 12 months.

  18. Visualisation of upper limb activity using spirals: A new approach to the assessment of daily prosthesis usage.

    PubMed

    Chadwell, Alix; Kenney, Laurence; Granat, Malcolm; Thies, Sibylle; Head, John S; Galpin, Adam

    2018-02-01

    Current outcome measures used in upper limb myoelectric prosthesis studies include clinical tests of function and self-report questionnaires on real-world prosthesis use. Research in other cohorts has questioned both the validity of self-report as an activity assessment tool and the relationship between clinical functionality and real-world upper limb activity. Previously, 1 we reported the first results of monitoring upper limb prosthesis use. However, the data visualisation technique used was limited in scope. Methodology development. To introduce two new methods for the analysis and display of upper limb activity monitoring data and to demonstrate the potential value of the approach with example real-world data. Upper limb activity monitors, worn on each wrist, recorded data on two anatomically intact participants and two prosthesis users over 1 week. Participants also filled in a diary to record upper limb activity. Data visualisation was carried out using histograms, and Archimedean spirals to illustrate temporal patterns of upper limb activity. Anatomically intact participants' activity was largely bilateral in nature, interspersed with frequent bursts of unilateral activity of each arm. At times when the prosthesis was worn prosthesis users showed very little unilateral use of the prosthesis (≈20-40 min/week compared to ≈350 min/week unilateral activity on each arm for anatomically intact participants), with consistent bias towards the intact arm throughout. The Archimedean spiral plots illustrated participant-specific patterns of non-use in prosthesis users. The data visualisation techniques allow detailed and objective assessment of temporal patterns in the upper limb activity of prosthesis users. Clinical relevance Activity monitoring offers an objective method for the assessment of upper limb prosthesis users' (PUs) activity outside of the clinic. By plotting data using Archimedean spirals, it is possible to visualise, in detail, the temporal patterns of upper limb activity. Further work is needed to explore the relationship between traditional functional outcome measures and real-world prosthesis activity.

  19. Functional evaluation of a CAD/CAM prosthesis for immediate defect repair after total maxillectomy: a case series of 18 patients with maxillary sinus cancer.

    PubMed

    Jiang, Fei-Fei; Hou, Yan; Lu, Li; Ding, Xiao-Xu; Li, Wei; Yan, Ai-Hui

    2015-01-01

    To evaluate the facial profiles and functional recovery of 18 patients treated by a computer-aided designed/manufactured hollow obturator prosthesis (CAD/CAM prosthesis) after total maxillectomy for malignant maxillary sinus tumor. A retrospective observational study was performed to evaluate the facial profiles and functional recovery of 18 patients with T3-4a N0 M0 maxillary sinus cancer, who were treated by total maxillectomy and simultaneous implantation of a computer-aided designed/manufactured hollow obturator prosthesis (CAD/CAM prosthesis). Follow-ups were performed 1, 3, 6, and 12 months after surgery. Facial measurements, speech intelligibility, and chewing and swallowing functions were examined. Thirteen patients converted to a permanent prosthesis 6 months after surgery. Comparisons were made between patients with and without the CAD/CAM or permanent prosthesis at various times using SPSS13.0 statistical software (SPSS Inc., Chicago, IL, USA). Speech intelligibility, facial depression, and eyeball prolapse results showed improvements with prosthesis use at 1, 3, and 6 months after surgery (p < 0.05). Swallowing function improved from level V to level II-IV with prosthesis use at 1, 3, and 6 months, and reached level I or II with permanent prosthesis use at 12 months after surgery. Simultaneous CAD/CAM prosthesis implantation recovered the facial profile, enhanced the speaking, swallowing, and chewing functions, and improved the quality of life of patients. Tumor recurrence can be detected by direct observation of the postoperative maxillary cavity. Therefore, this operation is recommended for simultaneous excision repair and functional reconstruction after total maxillectomy. This surgical treatment of maxillary sinus cancer is applied rarely in China, but it has a good effect based on our observation. Simultaneous CAD/CAM prosthesis implantation after total maxillectomy can recover the facial profile, enhance the speaking, swallowing, and chewing functions, and improve the quality of life of patients. Tumor recurrence can be detected by direct observation of the postoperative maxillary cavity. This technique avoids the need for dental implants because the bottom part of the prosthesis contains a palatal plate with dentures. © 2014 Wiley Periodicals, Inc.

  20. Replacement of the valvular prosthesis in a patient with a Bentall procedure.

    PubMed

    Panos, A L; Teoh, K T; Wilson, J K; Salerno, T A

    1992-09-01

    Patients who have had the Bentall-DeBono procedure using a composite conduit with a tissue valvular prosthesis pose a great challenge when problems develop with the tissue prosthesis. We herein report the surgical management of one such case, in which the valvular prosthesis was removed and replaced without replacement of the conduit.

  1. Vacuum form sheet as a guide for fabrication of orbital prosthesis.

    PubMed

    Dugad, Jinesh A; Dholam, Kanchan P; Chougule, Arati T

    2014-08-01

    Rehabilitation with an orbital prosthesis is done when surgical reconstruction is not possible or affordable in patients with orbital exenteration. Fabrication of orbital prosthesis requires precision in placement of the ocular portion of the prosthesis on the facial moulage. This method describes the use of a vacuum formed sheet for making an orbital template that acts as a guide for achieving optimum orientation of the ocular portion of the prosthesis. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. Management of an Anophthalmic Patient by the Fabrication of Custom Made Ocular Prosthesis

    PubMed Central

    SINGH, Meenakshi; NAYAK, Meghanand; SOLANKI, Jitender; GUPTA, Sarika; SINGH, Anjali

    2015-01-01

    The loss or disfigurement of a body parts specially that pertaining to the face has a deep psychological and social impact on the patient. After enucleation, evisceration or exteneration of the eye, the aim of an ocular prosthesis should be to restore the natural appearance, install confidence and a sense social acceptability in the patient. Custom made prosthesis has several advantages over the stock eye prosthesis. This article illustrates rehabilitation of the enucleated right eye of a patient with a custom made ocular prosthesis. PMID:26715901

  3. Assessment Methods for Restrictions in Manual Dexterity: Suitability for Exposure to the Cold

    DTIC Science & Technology

    2009-10-01

    palm is goat leather. The thermal comfort range of the gloves had been described recently (Zimmermann et al. 2008). Figure 1: Military five...sufficient to maintain the thermal comfort of the body. In the screw/bolt skill test restrictions in manual dexterity due to mechanical and haptical...temperature of the human body. J. Appl. Physiol. 19: 531-533 (1964). [10] Zimmermann, C., Uedelhoven, W. H., Kurz, B., Glitz, K. J.: Thermal comfort range

  4. Integrating Operational Energy Implications into System-Level Combat Effects Modeling: Assessing the Combat Effectiveness and Fuel Use of ABCT 2020 and Current ABCT

    DTIC Science & Technology

    2015-01-01

    Endy M. Daehner, John Matsumura, Thomas J. Herbert , Jeremy R. Kurz, Keith Walters Integrating Operational Energy Implications into System-Level... George Guthridge, and Megan Corso for their clear guid- ance and assistance throughout the study. We also received valuable information and insights from...helped with processing modeling and simulation outputs. Laura Novacic and Donna Mead provided invaluable administrative assistance and help with

  5. On the accuracy of models for predicting sound propagation in fitted rooms.

    PubMed

    Hodgson, M

    1990-08-01

    The objective of this article is to make a contribution to the evaluation of the accuracy and applicability of models for predicting the sound propagation in fitted rooms such as factories, classrooms, and offices. The models studied are 1:50 scale models; the method-of-image models of Jovicic, Lindqvist, Hodgson, Kurze, and of Lemire and Nicolas; the emprical formula of Friberg; and Ondet and Barbry's ray-tracing model. Sound propagation predictions by the analytic models are compared with the results of sound propagation measurements in a 1:50 scale model and in a warehouse, both containing various densities of approximately isotropically distributed, rectangular-parallelepipedic fittings. The results indicate that the models of Friberg and of Lemire and Nicolas are fundamentally incorrect. While more generally applicable versions exist, the versions of the models of Jovicic and Kurze studied here are found to be of limited applicability since they ignore vertical-wall reflections. The Hodgson and Lindqvist models appear to be accurate in certain limited cases. This preliminary study found the ray-tracing model of Ondet and Barbry to be the most accurate of all the cases studied. Furthermore, it has the necessary flexibility with respect to room geometry, surface-absorption distribution, and fitting distribution. It appears to be the model with the greatest applicability to fitted-room sound propagation prediction.

  6. Utilization of Microemulsions from Rhinacanthus nasutus (L.) Kurz to Improve Carotenoid Bioavailability

    PubMed Central

    Ho, Nai-Hsing; Inbaraj, Baskaran Stephen; Chen, Bing-Huei

    2016-01-01

    Carotenoids have been known to reduce the risk of several diseases including cancer and cardiovascular. However, carotenoids are unstable and susceptible to degradation. Rhinacanthus nasutus (L.) Kurz (R. nasutus), a Chinese medicinal herb rich in carotenoids, was reported to possess vital biological activities such as anti-cancer. This study intends to isolate carotenoids from R. nasutus by column chromatography, identify and quantify by HPLC-MS, and prepare carotenoid microemulsions for determination of absolute bioavailability in rats. Initially, carotenoid fraction was isolated using 250 mL ethyl acetate poured into an open-column packed with magnesium oxide-diatomaceous earth (1:3, w/w). Fourteen carotenoids including internal standard β-apo-8′-carotenal were resolved within 62 min by a YMC C30 column and gradient mobile phase of methanol-acetonitrile-water (82:14:4, v/v/v) and methylene chloride. Highly stable carotenoid microemulsions were prepared using a mixture of CapryolTM90, Transcutol®HP, Tween 80 and deionized water, with the mean particle being 10.4 nm for oral administration and 10.7 nm for intravenous injection. Pharmacokinetic study revealed that the absolute bioavailability of carotenoids in microemulsions and dispersion was 0.45% and 0.11%, respectively, while a much higher value of 6.25% and 1.57% were shown for lutein, demonstrating 4-fold enhancement in bioavailability upon incorporation of R. nasutus carotenoids into a microemulsion system. PMID:27150134

  7. Microstructures Evolution and Micromechanics Features of Ni-Cr-Si Coatings Deposited on Copper by Laser Cladding.

    PubMed

    Zhang, Peilei; Li, Mingchuan; Yu, Zhishui

    2018-05-23

    Three Ni-Cr-Si coatings were synthesized on the surface of copper by laser cladding. The microstructures of the coatings were characterized by optical microscopy (OM), X-ray diffraction (XRD), and scanning electron microscopy (SEM) with an energy dispersive spectrometer (EDS). According to the analysis results of phase compositions, Gibbs free energy change and microstructures, the phases of three coatings appeared were Cr₃Si+γ-Ni+Cu ss (Coating 1, Ni-26Cr-29Si), Cr₆Ni 16 Si₇+Ni₂Si+Cu ss (Coating 2, Ni-10Cr-30Si) and Cr₃Ni₅Si₂+Cr₂Ni₃+Cu ss (Coating 3, Ni-29Cr-16Si). The crystal growth in the solidification process was analyzed with a modified model, which is a combination of Kurz-Giovanola-Trivedi (KGT) and Lipton-Kurz-Trivedi (LKT) models. The dendrite tip undercooling in Coating 2 was higher than those of Coating 1 and Coating 3. Well-developed dendrites were found in Coating 2. A modification of Hunt’s model was adopted to describe the morphological differences in the three coatings. The results show that Coating 1 was in the equiaxed dendrite region, while Coatings 2 and 3 were in the columnar dendrite region. The average friction coefficients of the three coatings were 0.45, 0.5 and 0.4, respectively. Obvious plastic deformation could be found in the subsurface zone of Coatings 2 and 3.

  8. Design and preliminary biomechanical analysis of artificial cervical joint complex.

    PubMed

    Jian, Yu; Lan-Tao, Liu; Zhao, Jian-ning; Jian-ning, Zhao

    2013-06-01

    To design an artificial cervical joint complex (ACJC) prosthesis for non-fusion reconstruction after cervical subtotal corpectomy, and to evaluate the biomechanical stability, preservation of segment movements and influence on adjacent inter-vertebral movements of this prosthesis. The prosthesis was composed of three parts: the upper/lower joint head and the middle artificial vertebrae made of Cobalt-Chromium-Molybdenum (Co-Cr-Mo) alloy and polyethylene with a ball-and-socket joint design resembling the multi-axial movement in normal inter-vertebral spaces. Biomechanical tests of intact spine (control), Orion locking plate system and ACJC prosthesis were performed on formalin-fixed cervical spine specimens from 21 healthy cadavers to compare stability, range of motion (ROM) of the surgical segment and ROM of adjacent inter-vertebral spaces. As for stability of the whole lower cervical spine, there was no significant difference of flexion, extension, lateral bending and torsion between intact spine group and ACJC prosthesis group. As for segment movements, difference in flexion, lateral bending or torsion between ACJC prosthesis group and control group was not statistically significant, while ACJC prosthesis group showed an increase in extension (P < 0.05) compared to that of the control group. In addition, ACJC prosthesis group demonstrated better flexion, extension and lateral bending compared to those of Orion plating system group (P < 0.05). Difference in adjacent inter-vertebral ROM of the ACJC prosthesis group was not statistically significant compared to that of the control group. After cervical subtotal corpectomy, reconstruction with ACJC prosthesis not only obtained instant stability, but also reserved segment motions effectively, without abnormal gain of mobility at adjacent inter-vertebral spaces.

  9. Limitations of titanium dioxide and aluminum oxide as ossicular replacement materials: an evaluation of the effects of porosity on ceramic prostheses.

    PubMed

    Trabandt, Nicolaus; Brandes, Gudrun; Wintermantel, Erich; Lenarz, Thomas; Stieve, Martin

    2004-09-01

    Because the performance of titanium dioxide (TiO2) has not yet been assessed in the unique environment of the middle ear, its role as an ossicular replacement prototype in the form of a total ossicular replacement prosthesis (TORP) was tested and compared with aluminum oxide (Al2O3), once considered to be a suitable implant material. Ossiculoplasty was performed by implanting TORPs into the tympanic cavities of rabbits. After an implantation period of 28, 84, or 300 days, the petrous bones were extracted, whereby the biocompatibility of the prostheses was examined using light microscopy and scanning electron microscopy to determine morphologic changes in situ. Proper implant placement and functionality was tested via manual manipulation. Mucosa was seen covering most of the implants by day 84. Inflammatory cells were not observed in any of the specimens examined. The macroporous TiO2 TORPs were subjected to osseous infiltration, material dissolution, and fragmentation, whereas the microporous TiO2 implants were subjected to an increasing frequency of fissure formations. The Al2O3 prostheses demonstrated signs of material dissolution by producing encapsulated aggregates during the experimental trial period. Neither the macroporous nor microporous oxide ceramics were able to withstand the oscillatory stress to which they were continually subjected. Although porosity allows for the rapid integration of an implant material into a biological environment, its properties are not suited to fulfill the requirements of strength and long-term stability, which are demanded of middle ear prostheses.

  10. Gold nanoparticles on titanium and interaction with prototype protein.

    PubMed

    Padmos, J Daniel; Duchesne, Paul; Dunbar, Michael; Zhang, Peng

    2010-10-01

    Modifying titanium (Ti) implant surfaces with functional proteins can strengthen the interface between prosthesis and bone. A prototype system was developed using gold nanoparticles (AuNPs) to immobilize proteins onto Ti. An electroless (galvanic displacement) deposition method was first used to form AuNPs of controlled size and coverage on commercial Ti foil (giving Ti-AuNPs). Parameters were then modified to create two groups of discs (n = 26) with different average AuNP diameters. Scanning electron microscopy and X-ray photoelectron spectroscopy were used to characterize the morphology and surface structure of Ti-AuNPs. To study the interaction of Ti-AuNPs with proteins, Ti discs (n = 8) modified with plain AuNPs and discs (n = 8) modified with thiol (HS--R--COOH)-functionalized AuNPs were treated with lysozyme solution. The amount and activity of the lysozyme on the discs were examined with Micro-BCA and enzymatic assays. Lysozyme was immobilized onto the discs, and the assays showed that the discs with thiol-functionalized AuNPs, discs with bare AuNPs, and Ti controls had average lysozyme adsorptions of 23 x 10(4), 2.3 x 10(4), and 5.7 x 10(4) microg/m2, respectively. The activity assays showed that 21.5, 18.4, and 12.5% of the adsorbed lysozyme was active on the discs with thiol-functionalized AuNPs, discs with bare AuNPs, and Ti controls, respectively. This technique holds promise for binding functional biomolecules to surgical implants, hence possibly creating implant surfaces that react to their local environment. Copyright 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2010.

  11. Influence of different restorative materials on the stress distribution in dental implants.

    PubMed

    Datte, Carlos-Eduardo; Tribst, João-Paulo-Mendes; Dal Piva, Amanda-Maria-de Oliveira; Nishioka, Renato-Sussumu; Bottino, Marco-Antonio; Evangelhista, Alexandre-Duarte M; Monteiro, Fabrício M de M; Borges, Alexandre-Luiz-Souto

    2018-05-01

    To assist clinicians in deciding the most suitable restorative materials to be used in the crowns and abutment in implant rehabilitation. For finite element analysis (FEA), a regular morse taper implant was created using a computer aided design software. The implant was inserted at the bone model with 3 mm of exposed threads. An anatomic prosthesis representing a first maxillary molar was modeled and cemented on the solid abutment. Considering the crown material (zirconia, chromium-cobalt, lithium disilicate and hybrid ceramic) and abutment (Titanium and zirconia), the geometries were multiplied, totaling eight groups. In order to perform the static analysis, the contacts were considered bonded and each material was assigned as isotropic. An axial load (200 N) was applied on the crown and fixation occurred on the base of the bone. Results using Von-Mises criteria and micro strain values were obtained. A sample identical to the CAD model was made for the Strain Gauge (SG) analysis; four SGs were bonded around the implant to obtain micro strain results in bone tissue. FEA results were 3.83% lower than SG. According to the crown material, it is possible to note that the increase of elastic modulus reduces the stress concentration in all system without difference for bone. Crown materials with high elastic modulus are able to decrease the stress values in the abutments while concentrates the stress in its structure. Zirconia abutments tend to concentrate more stress throughout the prosthetic system and may be more susceptible to mechanical problems than titanium. Key words: Finite element analysis, dental implants, ceramic.

  12. Natural teeth-retained splint based on a patient-specific 3D-printed mandible used for implant surgery and vestibuloplasty

    PubMed Central

    Xing, Helin; Wu, Jinshuang; Zhou, Lei; Yang, Sefei

    2017-01-01

    Abstract Rationale: With respect to improving the quality of oral rehabilitation, the management of keratinized mucosa is as important as bone condition for implant success. To enhance this management, a natural teeth-retained splint based on a patient-specific 3-dimensional (3D) printed mandible was used in vestibuloplasty to provide sufficient keratinized mucosa around dental implants to support long-term implant maintenance. Patient concerns: A 28-year-old male patient had a fracture of the anterior andible 1 year ago, and the fracture was treated with titanium. Diagnoses: The patient had lost mandibular incisors on both the sides and had a shallow vestibule and little keratinized mucosa. Interventions: In the first-stage implant surgery, 2 implants were inserted and the titanium fracture fixation plates and screws were removed at the same time. During second-stage implant surgery, vestibuloplasty was performed, and the natural teeth-retained splint was applied. The splint was made based upon a patient-specific 3D-printed mandible. At 30-day follow-up, the splint was modified and reset. The modified splint was removed after an additional 60 days, and the patient received prosthetic treatment. Outcomes: After prosthetic treatment, successful oral rehabilitation was achieved. Within 1 year and 3 years after implant prosthesis finished, the patient exhibited a good quantity of keratinized gingiva. Lessons subsections: The proposed splint is a simple and time-effective technique for correcting soft tissue defects in implant dentistry that ensures a good quantity of keratinized mucosa. PMID:29310359

  13. Use of prostheses in lower limb amputee patients due to peripheral arterial disease

    PubMed Central

    Chamlian, Therezinha Rosane

    2014-01-01

    Objective To evaluate the indication of prosthesis during rehabilitation and the maintenance of their use or abandonment rate after discharge, as well as mortality of lower limb amputees due to peripheral arterial disease. Methods A retrospective and cross-sectional study carried out with lower limb amputee patients, at transfemoral and transtibial levels, due to vascular conditions. The sample was composed of 310 patients (205 men, 105 women, mean age 61.8 years), transfemoral (142) and transtibial (150) levels, unilateral or bilateral (18). A total of 217 were fitted with prosthesis and 93 did not. Nonparametric statistical tests with equality of two proportions, 95% confidence interval and p value <0,05 were used. Results Out of 195 patients we contacted, 151 were fitted with prosthesis and 44 not. Of those that were fitted with prosthesis, 54 still use it, 80 abandoned and 17 died. In the group without prosthesis, 27 were on wheelchair and 17 died. Mortality is statistically higher among patients who were not fitted with prosthesis and 34 death occur, on average, 3.91 years after amputation. Survival time of patients who were not fitted with prosthesis was smaller than those were fitted. Conclusion The use of prosthesis in lower limb amputees, due to vascular conditions, during rehabilitation is high. However, maintenance of prosthesis is not frequent after discharge. Early and high mortality is observed mainly among diabetic patients. PMID:25628194

  14. Prosthesis use in adult acquired major upper-limb amputees: patterns of wear, prosthetic skills and the actual use of prostheses in activities of daily life.

    PubMed

    Østlie, Kristin; Lesjø, Ingrid Marie; Franklin, Rosemary Joy; Garfelt, Beate; Skjeldal, Ola Hunsbeth; Magnus, Per

    2012-11-01

    To describe patterns of prosthesis wear and perceived prosthetic usefulness in adult acquired upper-limb amputees (ULAs). To describe prosthetic skills in activities of daily life (ADL) and the actual use of prostheses in the performance of ADL tasks. To estimate the influence of prosthetic skills on actual prosthesis use and the influence of background factors on prosthetic skills and actual prosthesis use. Cross-sectional study analysing population-based questionnaire data (n = 224) and data from interviews and clinical testing in a referred/convenience sample of prosthesis-wearing ULAs (n = 50). Effects were analysed using linear regression. 80.8% wore prostheses. 90.3% reported their most worn prosthesis as useful. Prosthetic usefulness profiles varied with prosthetic type. Despite demonstrating good prosthetic skills, the amputees reported actual prosthesis use in only about half of the ADL tasks performed in everyday life. In unilateral amputees, increased actual use was associated with sufficient prosthetic training and with the use of myoelectric vs cosmetic prostheses, regardless of amputation level. Prosthetic skills did not affect actual prosthesis use. No background factors showed significant effect on prosthetic skills. Most major ULAs wear prostheses. Individualised prosthetic training and fitting of myoelectric rather than passive prostheses may increase actual prosthesis use in ADL.

  15. Early outcome of TKA with a medial pivot fixed-bearing prosthesis is worse than with a PFC mobile-bearing prosthesis.

    PubMed

    Kim, Young-Hoo; Yoon, Sung-Hwan; Kim, Jun-Shik

    2009-02-01

    Although the design features of the Medial Pivot fixed-bearing prosthesis reportedly improve kinematics compared with TKAs using fixed-bearings, clinical improvements have not been reported. We asked whether the clinical and radiographic outcomes, ranges of motion of the knee, patient satisfaction, and complication rates would be better in knees with a Medial Pivot fixed-bearing prosthesis than in those with a PFC Sigma mobile-bearing prosthesis. We compared the results of 92 patients who had a Medial Pivot fixed-bearing prosthesis implanted in one knee and a PFC Sigma mobile-bearing prosthesis implanted in the other. There were 85 women and seven men with a mean age of 69.5 years (range, 55-81 years). The minimum followup was 2 years (mean, 2.6 years; range, 2-3 years). The patients were assessed clinically and radiographically using the rating systems of the Hospital for Special Surgery and the Knee Society at 3 months, 1 year, and annually thereafter. Contrary to expectations, we found worse early clinical outcomes, smaller ranges of knee motion, less patient satisfaction, and a higher complication rate for the Medial Pivot fixed-bearing prosthesis than for the PFC Sigma mobile-bearing prosthesis. Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  16. Frequency of technical complications in fixed implant prosthesis: the effect of prosthesis screw emergence correction by CAD-CAM.

    PubMed

    Anitua, Eduardo; Flores, Carlos; Piñas, Laura; Alkhraisat, Mohammad

    2018-06-05

    CAD-CAM technology permits the angular correction of screw emergence into the prosthesis, however there is lack of controlled clinical studies that assess the frequency of technical complications in angled screw channel restorations. This controlled clinical study was designed to assess technical incidences in angled screw channel restorations. Patients having implant prosthesis placed between November, 2014 and December, 2015 were screened. The patients were selected if they received prosthesis with up to 30º correction of the prosthesis screw emergence and had at least one non-angulated prosthesis (screw-retained). All the prostheses were located completely/partially in the posterior region. The frequency of technical complications was the principal variable. A total of 52 patients with a mean age of 62 ± 10 years participated with a total 110 prostheses (55 in the test group and 55 in the control group). A total of 11 technical complications occurred (7 in the test group and 4 in the control group). These differences were not statistically significant. All the prostheses in both groups survived the follow-up. The correction of the screw emergence into the prosthesis has not increased the risk of technical complications in CAD-CAM implant prostheses.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Janik, Gregory

    Renders, saves, and analyzes pressure from several sensors in a prosthesis™ socket. The program receives pressure data from 64 manometers and parses the pressure for each individual sensor. The program can then display those pressures as number in a table. The program also interpolates pressures between manometers to create a larger set of data. This larger set of data is displayed as a simple contour plot. That same contour plot can also be placed on a three-dimensional surface in the shape of a prosthesis.This program allows for easy identification of high pressure areas in a prosthesis to reduce the user™smore » discomfort. The program parses the sensor pressures into a human-readable numeric format. The data may also be used to actively adjust bladders within the prosthesis to spread out pressure in real time, according to changing demands placed on the prosthesis. Interpolation of the pressures to create a larger data set makes it even easier for a human to identify particular areas of the prosthesis that are under high pressure. After identifying pressure points, a prosthetician can then redesign the prosthesis and/or command the bladders in the prosthesis to attempt to maintain constant pressures.« less

  18. Allograft-prosthesis composites after bone tumor resection at the proximal tibia.

    PubMed

    Biau, David Jean; Dumaine, Valérie; Babinet, Antoine; Tomeno, Bernard; Anract, Philippe

    2007-03-01

    The survival of irradiated allograft-prosthesis composites at the proximal tibia is mostly unknown. However, allograft-prosthesis composites have proved beneficial at other reconstruction sites. We presumed allograft-prosthesis composites at the proximal tibia would improve survival and facilitate reattachment of the extensor mechanism compared with that of conventional (megaprostheses) reconstructions. We retrospectively reviewed 26 patients who underwent resection of proximal tibia tumors followed by reconstruction with allo-graft-prosthesis composites. Patients received Guepar massive custom-made fully constrained prostheses. Allografts were sterilized with gamma radiation, and the stems were cemented into the allograft and host bone. The minimum followup was 6 months (median, 128 months; range, 6-195 months). Fourteen patients had one or more components removed. The median allograft-prosthesis composite survival was 102 months (95% confidence interval, 64.2-infinity). Of the 26 allografts, seven fractured, six showed signs of partial resorption, and six had infections develop. Seven allografts showed signs of fusion with the host bone. Six extensor mechanism reconstructions failed. Allograft-prosthesis composites sterilized by gamma radiation yielded poor results for proximal tibial reconstruction as complications and failures were common. We do not recommend irradiated allograft-prosthesis composites for proximal tibia reconstruction.

  19. Simulation of a slope adapting ankle prosthesis provided by semi-active damping.

    PubMed

    LaPrè, Andrew K; Sup, Frank

    2011-01-01

    Modern passive prosthetic foot/ankles cannot adapt to variations in ground slope. The lack of active adaptation significantly compromises an amputee's balance and stability on uneven terrains. To address this deficit, this paper proposes an ankle prosthesis that uses semi-active damping as a mechanism to provide active slope adaptation. The conceptual ankle prosthesis consists of a modulated damper in series with a spring foot that allows the foot to conform to the angle of the surface in the sagittal plane. In support of this approach, biomechanics data is presented showing unilateral transtibial amputees stepping on a wedge with their daily-use passive prosthesis. Based on this data, a simulation of the ankle prosthesis with semi-active damping is developed. The model shows the kinematic adaptation of the prosthesis to sudden changes in ground slope. The results show the potential of an ankle prosthesis with semi-active damping to actively adapt to the ground slope at each step.

  20. In vitro biomechanical comparison after fixed- and mobile-core artificial cervical disc replacement versus fusion

    PubMed Central

    Lou, Jigang; Li, Yuanchao; Wang, Beiyu; Meng, Yang; Wu, Tingkui; Liu, Hao

    2017-01-01

    Abstract In vitro biomechanical analysis after cervical disc replacement (CDR) with a novel artificial disc prosthesis (mobile core) was conducted and compared with the intact model, simulated fusion, and CDR with a fixed-core prosthesis. The purpose of this experimental study was to analyze the biomechanical changes after CDR with a novel prosthesis and the differences between fixed- and mobile-core prostheses. Six human cadaveric C2–C7 specimens were biomechanically tested sequentially in 4 different spinal models: intact specimens, simulated fusion, CDR with a fixed-core prosthesis (Discover, DePuy), and CDR with a mobile-core prosthesis (Pretic-I, Trauson). Moments up to 2 Nm with a 75 N follower load were applied in flexion–extension, left and right lateral bending, and left and right axial rotation. The total range of motion (ROM), segmental ROM, and adjacent intradiscal pressure (IDP) were calculated and analyzed in 4 different spinal models, as well as the differences between 2 disc prostheses. Compared with the intact specimens, the total ROM, segmental ROM, and IDP at the adjacent segments showed no significant difference after arthroplasty. Moreover, CDR with a mobile-core prosthesis presented a little higher values of target segment (C5/6) and total ROM than CDR with a fixed-core prosthesis (P > .05). Besides, the difference in IDP at C4/5 after CDR with 2 prostheses was without statistical significance in all the directions of motion. However, the IDP at C6/7 after CDR with a mobile-core prosthesis was lower than CDR with a fixed-core prosthesis in flexion, extension, and lateral bending, with significant difference (P < .05), but not under axial rotation. CDR with a novel prosthesis was effective to maintain the ROM at the target segment and did not affect the ROM and IDP at the adjacent segments. Moreover, CDR with a mobile-core prosthesis presented a little higher values of target segment and total ROM, but lower IDP at the inferior adjacent segment than CDR with a fixed-core prosthesis. PMID:29019902

  1. Difference in occurrence of heterotopic ossification according to prosthesis type in the cervical artificial disc replacement.

    PubMed

    Yi, Seong; Kim, Keung Nyun; Yang, Moon Sul; Yang, Joong Won; Kim, Hoon; Ha, Yoon; Yoon, Do Heum; Shin, Hyun Chul

    2010-07-15

    Retrospective study of the difference of heterotopic ossification (HO) occurrence according to 3 different types of prosthesis. This study was designed to investigate the difference of HO occurrence according to different type of prosthesis. HO is defined as formation of the bone outside the skeletal system. Reported HO occurrence rate in cervical artificial disc replacement (ADR) was unexpectedly high and varied. But the influencing factors of HO in cervical ADR have not been elucidated well. The prosthesis-related factors for making difference of HO occurrence were investigated in this study. A total of 170 patients undergoing cervical arthroplasty with the Bryan cervical disc prosthesis (Medtroic Sofamor Danek, Memphis, TN), Mobi-C disc prosthesis (LDR Medical, Troyes, France), and ProDisc-C (Synthes, Inc., West Chester, PA) were included. Cervical lateral radiographs obtained before and after surgery were used to identify HO. Occurrence rate, occurrence-free period, location, and grade of HOs were investigated according to the different prosthesis. Each prosthesis group included patients as follows: Bryan disc, 81 patients; Mobi-C, 61 patients; and ProDisc-C, 28 patients. Overall HO rate was 40.6% (69 of 170 patients). Each HO occurrence rate by prosthesis was as follows: the Bryan disc group, 21.0%; Mobi-C group, 52.5%; and the ProDisc-C group, 71.4%. In the survival analysis, all patients showed 27.1 +/- 3.7 months as the median survival. The Bryan disc group showed statistically longer survival (48.4 +/- 7.4 months) than the other groups. Occurrence of HO is an inevitable postoperative complication after cervical ADR. The occurrence rate of HO was higher than our expectation. Moreover, definite differences in occurrence rate according to the prosthesis type were identified by this study.

  2. Seventeen-millimeter St. Jude Medical Regent valve in patients with small aortic annulus: dose moderate prosthesis-patient mismatch matter?

    PubMed

    Hu, Jia; Qian, Hong; Li, Ya-jiao; Gu, Jun; Zhao, Jing Janice; Zhang, Er-yong

    2014-01-17

    The study was designed to evaluate the effects of moderate prosthesis-patient mismatch (defined as 0.65 cm(2)/m(2) 

  3. Long-term outcome of giant cell tumors of bone around the knee treated by en bloc resection of tumor and reconstruction with prosthesis.

    PubMed

    Yu, Xiu-chun; Xu, Ming; Song, Ruo-xian; Fu, Zhi-hou; Liu, Xiao-ping

    2010-08-01

    To study the long-term outcomes and complications of giant cell tumors around the knee treated with en bloc resection and reconstruction with prosthesis. From January 1991 to March 2005, 19 patients (11 men, 8 women, average age 35.4 years) were treated in our hospital with en bloc resection and reconstruction with domestic prosthesis (15 hinge knee and 4 rotating-hinge knee). The distal femur was involved in 12 and the proximal tibia in 7 cases. Nine tumors were primary and 10 recurrent. All cases were Campanacci grade III. The affected limb functions were evaluated by the Musculoskeletal Tumor Society scoring system. All patients underwent operation successfully with no complications. The mean follow-up time was 128.9 months (60 to 216 months). Apart from one patient who underwent amputation because of wound infection two years after reoperation, the range of knee motion of 18 patients was 30°-110°. The mean functional score of the affected limb was 22.7 (15 to 27 points). The length of the lower extremities was equal in nine cases; the affected limb was 2-9 cm shorter in the other ten cases. Prosthesis fracture and loosening developed in one, prosthesis aseptic loosening in three, and delayed deep infection and prosthesis loosening in two cases. The prosthesis loosening rate was 31.6%. One patient developed a proximal femur fracture. En bloc resection and reconstruction with prosthesis is a feasible method for treating giant cell tumor of bone around the knee. Complications related to the prosthesis, mainly prosthesis loosening and limb shortening, increase gradually with longer survival time. © 2010 Tianjin Hospital and Blackwell Publishing Asia Pty Ltd.

  4. A novel open-tray impression technique for fabrication of a provisional prosthesis on immediate load implants in a completely edentulous arch.

    PubMed

    Kaneko, Takahiro; Yamagishi, Kiyoshi; Horie, Norio; Shimoyama, Tetsuo

    2013-01-01

    To evaluate the clinical outcome of a novel open-tray impression technique for fabrication of a provisional prosthesis supported by immediately loaded implants in a completely edentulous arch. An open-tray impression technique was evaluated in this retrospective study that included patients treated between March 2006 and October 2009. Preoperatively, a diagnostic prosthesis was delivered, and a novel open tray was fabricated based on this prosthesis. After implant placement, the impression and interocclusal record were taken simultaneously using the novel open tray. Laboratory-fabricated, screw-retained, all-acrylic resin provisional restorations were delivered on the same day of surgery. The prosthesis was assessed from the day of surgery until replacement with a definitive prosthesis. The study included 21 patients (mean age, 64.5 years) and a total of 125 implants. Of these, 104 implants were immediately loaded. In all patients, well-fitting provisional restorations supported by a minimum of four implants were delivered. Fracture of the first molar cusp was observed in one case after 30 days. However, there was no extensive fracture in the framework or functional disorder of the prosthesis. No implant failed during the follow-up after implant surgery. This protocol enabled fabrication of a well-fitting acrylic resin provisional prosthesis supported by immediately loaded implants because the impression was taken while in centric occlusion and an occlusion identical to the diagnostic prosthesis could be reconstructed.

  5. Isolation and structure elucidation of a new indole alkaloid from Rauvolfia serpentina hairy root culture: the first naturally occurring alkaloid of the raumacline group.

    PubMed

    Sheludko, Yuri; Gerasimenko, Irina; Kolshorn, Heinz; Stöckigt, Joachim

    2002-05-01

    A new monoterpenoid indole alkaloid, 10-hydroxy- N(alpha)-demethyl-19,20-dehydroraumacline ( 1), was isolated as a mixture of E- and Z-isomers from hairy root culture of Rauvolfia serpentina Benth. ex Kurz (Apocynaceae) and the structure was determined by 1D and 2D NMR analyses. The new indole alkaloid represents the first naturally occurring alkaloid of the raumacline group and its putative biosynthetical pathway is discussed.

  6. Microlocalization and Quantitation of Risk Associated Elements in Gleason Graded Prostate Tissue

    DTIC Science & Technology

    2006-03-01

    with NADC and NADH as studied by electrospray ionization mass spectrometry and 11B NMR spectroscopy , J. Mass Spectrom. 38 (2003) 632–640. [19] D.H. Kim...spectrometry and 11B NMR spectroscopy . J Mass Spectrom 38: 632 – 640 Kurz DJ, Decary S, Hong Y, Erusalimsky JD (2000) Senescence-associated (beta...232 – 235 Semmelhack MF, Campagna SR, Hwa C, Federle MJ, Bassler BL (2004) Boron binding with the quorum sensing signal AI-2 and analogues . Org Lett 6

  7. Bereits nach Ablauf der Halbwertszeit droht der vollständige Zerfall Die britische Atomic Scientists’ Association, die Ideologie der „objektiven” Wissenschaft und die H-Bombe

    NASA Astrophysics Data System (ADS)

    Laucht, Christoph

    Präsident Harry Trumans Verlautbarung vom 31.1.1950, seine Regierung wolle die Entwicklung der Wasserstoffbombe vorantreiben, fand große Beachtung in den britischen Medien. Die illustrierte Zeitschrift Picture Post widmete der HBombe einen Artikel, der unter anderem kurze Stellungnahmen der britischen Atomwissenschaftler Eric Burhop, Kathleen Lonsdale, Harrie Massey, Rudolf Peierls und Maurice Pryce enthielt, die alle Mitglieder der Atomic Scientists' Association (ASA) waren.

  8. Using Arrays of Microelectrodes Implanted in Residual Peripheral Nerves to Provide Dextrous Control of, and Modulated Sensory Feedback from, a Hand Prosthesis

    DTIC Science & Technology

    2015-10-01

    Modulated Sensory Feedback from, a Hand Prosthesis PRINCIPAL INVESTIGATOR: Bradley Greger, PhD CONTRACTING ORGANIZATION: Arizona State University...Residual Peripheral Nerves to Provide Dextrous Control of, and Modulated Sensory Feedback from, a Hand Prosthesis 5a. CONTRACT NUMBER 5b. GRANT...Peripheral Nerve Interface, Prosthetic Hand, Neural Prosthesis , Sensory Feedback, Micro-stimulation, Electrophysiology, Action Potentials, Micro

  9. Flexible and static wrist units in upper limb prosthesis users: functionality scores, user satisfaction and compensatory movements.

    PubMed

    Deijs, M; Bongers, R M; Ringeling-van Leusen, N D M; van der Sluis, C K

    2016-03-15

    The current study examines the relevance of prosthetic wrist movement to facilitate activities of daily living or to prevent overuse complaints. Prosthesis hands with wrist flexion/extension capabilities are commercially available, but research on the users' experiences with flexible wrists is limited. In this study, eight transradial amputees using a myoelectric prosthesis tested two prosthesis wrists with flexion/extension capabilities, the Flex-wrist (Otto Bock) and Multi-flex wrist (Motion Control), in their flexible and static conditions. Differences between the wrists were assessed on the levels of functionality, user satisfaction and compensatory movements after two weeks use. No significant differences between flexible and static wrist conditions were found on activity performance tests and standardized questionnaires on satisfaction. Inter-individual variation was remarkably large. Participants' satisfaction tended to be in favour of flexible wrists. All participants but one indicated that they would choose a prosthesis hand with wrist flexion/extension capabilities if allowed a new prosthesis. Shoulder joint angles, reflecting compensatory movements, showed no clear differences between wrist conditions. Overall, positive effects of flexible wrists are hard to objectify. Users seem to be more satisfied with flexible wrists. A person's needs, work and prosthesis skills should be taken into account when prescribing a prosthesis wrist. Nederlands Trial Register NTR3984 .

  10. Adjuvant Maneuvers for Residual Curvature Correction During Penile Prosthesis Implantation in Men with Peyronie's Disease.

    PubMed

    Berookhim, Boback M; Karpman, Edward; Carrion, Rafael

    2015-11-01

    The surgical treatment of comorbid erectile dysfunction and Peyronie's disease has long included the implantation of an inflatable penile prosthesis as well as a number of adjuvant maneuvers to address residual curvature after prosthesis placement. To review the various surgical options for addressing curvature after prosthesis placement, with specific attention paid to an original article by Wilson et al. reporting on modeling over a penile prosthesis for the management of Peyronie's disease. A literature review was performed analyzing articles reporting the management of penile curvature in patients undergoing implantation of an inflatable penile prosthesis. Reported improvement in Peyronie's deformity as well as the complication rate associated with the various surgical techniques described. Modeling is a well-established treatment modality among patients with Peyronie's disease undergoing penile prosthesis implantation. A variety of other adjuvant maneuvers to address residual curvature when modeling alone is insufficient has been presented in the literature. Over 20 years of experience with modeling over a penile prosthesis have proven the efficacy and safety of this treatment option, providing the surgeon a simple initial step for the management of residual curvature after penile implantation which allows for the use of additional adjuvant maneuvers in those with significant deformities. © 2015 International Society for Sexual Medicine.

  11. Active upper limb prosthesis based on natural movement trajectories.

    PubMed

    Ramírez-García, Alfredo; Leija, Lorenzo; Muñoz, Roberto

    2010-03-01

    The motion of the current prostheses is sequential and does not allow natural movements. In this work, complex natural motion patterns from a healthy upper limb were characterized in order to be emulated for a trans-humeral prosthesis with three degrees of freedom at the elbow. Firstly, it was necessary to define the prosthesis workspace, which means to establish a relationship using an artificial neural network (ANN), between the arm-forearm (3-D) angles allowed by the prosthesis, and its actuators length. The 3-D angles were measured between the forearm and each axis of the reference system attached at the elbow. Secondly, five activities of daily living (ADLs) were analyzed by means of the elbow flexion (EF), the forearm prono-supination (FPS) and the 3-D angles, from healthy subjects, by using a video-based motion analysis system. The 3-D angles were fed to the prosthesis model (ANN) in order to analyze which ADLs could be emulated by the prosthesis. As a result, a prosthesis kinematics approximation was obtained. In conclusion, in spite of the innovative mechanical configuration of the actuators, it was possible to carry out only three of the five ADLs considered. Future work will include improvement of the mechanical configuration of the prosthesis to have greater range of motion.

  12. The effects of indwelling voice prosthesis on the quality of life, depressive symptoms, and self-esteem in patients with total laryngectomy.

    PubMed

    Polat, Beldan; Orhan, Kadir Serkan; Kesimli, Mustafa Caner; Gorgulu, Yasemin; Ulusan, Murat; Deger, Kemal

    2015-11-01

    This study aims to evaluate the effects of voice rehabilitation with indwelling voice prosthesis on quality of life, depression, anxiety, self-esteem, and sexual functions in laryngectomy patients. Provox-1 was applied to 30 patients who underwent total laryngectomy by opening a tracheoesophageal fistula. WHO Quality of Life-BREF, Beck Depression Inventory, Beck Anxiety Inventory, Rosenberg Self-Esteem Scale, Arizona Sexual Experience Scale forms were asked to be filled out by the patients before voice prosthesis application. These tests were asked to be filled out again 3 months later after the voice prosthesis application. Paired samples and Wilcoxon tests were used to compare before and after operation values. Indwelling voice prosthesis was found to improve quality of life, self-esteem, and sexual function (p < 0.05). Additionally, symptoms of depression and anxiety were regressed (p < 0.05). Indwelling voice prosthesis was found to especially increase the quality of life and decrease depression (p < 0.05). This study is an uncontrolled single-arm study comparing patients' psychosocial statuses pre- and post-voice prosthesis.

  13. Effect of Framework in an Implant-Supported Full-Arch Fixed Prosthesis: 3D Finite Element Analysis.

    PubMed

    Menini, Maria; Pesce, Paolo; Bevilacqua, Marco; Pera, Francesco; Tealdo, Tiziano; Barberis, Fabrizio; Pera, Paolo

    2015-01-01

    The aim of this study was to analyze through a three-dimensional finite element analysis (3D-FEA) stress distribution on four implants supporting a full-arch implant-supported fixed prosthesis (FFP) using different prosthesis designs. A 3D edentulous maxillary model was created and four implants were virtually placed into the maxilla and splinted, simulating an FFP without framework, with a cast metal framework, and with a carbon fiber framework. An occlusal load of 150 N was applied, stresses were transmitted into peri-implant bone, and prosthodontic components were recorded. 3D-FEA revealed higher stresses on the implants (up to +55.16%), on peri-implant bone (up to +56.93%), and in the prosthesis (up to +70.71%) when the full-acrylic prosthesis was simulated. The prosthesis with a carbon fiber framework showed an intermediate behavior between that of the other two configurations. This study suggests that the presence of a rigid framework in full-arch fixed prostheses provides a better load distribution that decreases the maximum values of stress at the levels of implants, prosthesis, and maxillary bone.

  14. Control and Evaluation of a Powered Transfemoral Prosthesis for Stair Ascent.

    PubMed

    Ledoux, Elissa D; Goldfarb, Michael

    2017-07-01

    This paper assesses the metabolic effort exerted by three transfemoral amputees, when using a powered knee and ankle prosthesis for stair ascent, relative to ascending stairs with passive knee and ankle prostheses. The paper describes a controller that provides step-over stair ascent behavior reflective of healthy stair ascent biomechanics, and describes its implementation in a powered prosthesis prototype. Stair ascent experiments were performed with three unilateral transfemoral amputee subjects, comparing the oxygen consumption required to ascend stairs using the powered prosthesis (with a step-over gait), relative to using their daily-use energetically passive prostheses (with a step-to gait). Results indicate on average a 24% reduction in oxygen consumption and a 30% reduction in stair ascent timewhen using the powered prosthesis, relative to when using the passive prostheses. All subjects expressed a strong preference for ascending stairs using the powered prosthesis.

  15. Rehabilitation of orbital cavity after orbital exenteration using polymethyl methacrylate orbital prosthesis.

    PubMed

    Jain, Sumeet; Jain, Parul

    2016-01-01

    Squamous cell carcinoma of the eyelid is the second most common malignant neoplasm of the eye with the incidence of 0.09 and 2.42 cases/100 000 people. Orbital invasion is a rare complication but, if recognized early, can be treated effectively with exenteration. Although with advancements in technology such as computer-aided design and computer-aided manufacturing, material science, and retentive methods like implants, orbital prosthesis with stock ocular prosthesis made of methyl methacrylate retained by anatomic undercuts is quiet effective and should not be overlooked and forgotten. This clinical report describes prosthetic rehabilitation of two male patients with polymethyl methacrylate resin orbital prosthesis after orbital exenteration, for squamous cell carcinoma of the upper eyelid. The orbital prosthesis was sufficiently retained by hard and soft tissue undercuts without any complications. The patients using the prosthesis are quite satisfied with the cosmetic results and felt comfortable attending the social events.

  16. Catastrophic metallosis after tumoral knee prosthesis failure: A case report.

    PubMed

    La Verde, Luca; Fenga, Domenico; Spinelli, Maria Silvia; Campo, Francesco Rosario; Florio, Michela; Rosa, Michele Attilio

    2017-01-01

    Metallosis is a condition characterized by an infiltration of periprosthetic soft tissues and bone by metallic debris resulting from wear or failure of joint arthroplasties. Authors describe a case of a 45-year-old man treated for an osteosarcoma of the distal femur with a modular prosthesis when he was 18 years old, he developed massive metallosis with skin dyspigmentation after 17 years. His medical\\surgical history was remarkable for a left tumoral knee prosthesis implanted 21 years ago. Two years before revision, the patient had a car accident with a two-points prosthesis breakage and despite the surgeon's advice, the patient refused surgery. In two years, prosthesis malfunction caused a progressive catastrophic soft tissues infiltration of metallic debris. Authors suggest that if prosthesis fracture is detected, revision surgery should be attempted as earlier as possible. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Microbial biofilms on facial prostheses.

    PubMed

    Ariani, Nina; Vissink, Arjan; van Oort, Robert P; Kusdhany, Lindawati; Djais, Ariadna; Rahardjo, Tri Budi W; van der Mei, Henny C; Krom, Bastiaan P

    2012-01-01

    The composition of microbial biofilms on silicone rubber facial prostheses was investigated and compared with the microbial flora on healthy and prosthesis-covered skin. Scanning electron microscopy showed the presence of mixed bacterial and yeast biofilms on and deterioration of the surface of the prostheses. Microbial culturing confirmed the presence of yeasts and bacteria. Microbial colonization was significantly increased on prosthesis-covered skin compared to healthy skin. Candida spp. were exclusively isolated from prosthesis-covered skin and from prostheses. Biofilms from prostheses showed the least diverse band-profile in denaturing gradient gel electrophoresis (DGGE) whereas prosthesis-covered skin showed the most diverse band-profile. Bacterial diversity exceeded yeast diversity in all samples. It is concluded that occlusion of the skin by prostheses creates a favorable niche for opportunistic pathogens such as Candida spp. and Staphylococcus aureus. Biofilms on healthy skin, skin underneath the prosthesis and on the prosthesis had a comparable composition, but the numbers present differed according to the microorganism.

  18. Amputation and prosthesis implantation shape body and peripersonal space representations

    PubMed Central

    Canzoneri, Elisa; Marzolla, Marilena; Amoresano, Amedeo; Verni, Gennaro; Serino, Andrea

    2013-01-01

    Little is known about whether and how multimodal representations of the body (BRs) and of the space around the body (Peripersonal Space, PPS) adapt to amputation and prosthesis implantation. In order to investigate this issue, we tested BR in a group of upper limb amputees by means of a tactile distance perception task and PPS by means of an audio-tactile interaction task. Subjects performed the tasks with stimulation either on the healthy limb or the stump of the amputated limb, while wearing or not wearing their prosthesis. When patients performed the tasks on the amputated limb, without the prosthesis, the perception of arm length shrank, with a concurrent shift of PPS boundaries towards the stump. Conversely, wearing the prosthesis increased the perceived length of the stump and extended the PPS boundaries so as to include the prosthetic hand, such that the prosthesis partially replaced the missing limb. PMID:24088746

  19. Development and performance of a new prosthesis system using ultrasonic sensor for wrist movements: a preliminary study

    PubMed Central

    2014-01-01

    Background The design and performance of a new development prosthesis system known as biomechatronics wrist prosthesis is presented in this paper. The prosthesis system was implemented by replacing the Bowden tension cable of body powered prosthesis system using two ultrasonic sensors, two servo motors and microcontroller inside the prosthesis hand for transradial user. Methods The system components and hand prototypes involve the anthropometry, CAD design and prototyping, biomechatronics engineering together with the prosthetics. The modeler construction of the system develop allows the ultrasonic sensors that are placed on the shoulder to generate the wrist movement of the prosthesis. The kinematics of wrist movement, which are the pronation/supination and flexion/extension were tested using the motion analysis and general motion of human hand were compared. The study also evaluated the require degree of detection for the input of the ultrasonic sensor to generate the wrist movements. Results The values collected by the vicon motion analysis for biomechatronics prosthesis system were reliable to do the common tasks in daily life. The degree of the head needed to bend to give the full input wave was about 45° - 55° of rotation or about 14 cm – 16 cm. The biomechatronics wrist prosthesis gave higher degree of rotation to do the daily tasks but did not achieve the maximum degree of rotation. Conclusion The new development of using sensor and actuator in generating the wrist movements will be interesting for used list in medicine, robotics technology, rehabilitations, prosthetics and orthotics. PMID:24755242

  20. Virtual transplantation in designing a facial prosthesis for extensive maxillofacial defects that cross the facial midline using computer-assisted technology.

    PubMed

    Feng, Zhi-hong; Dong, Yan; Bai, Shi-zhu; Wu, Guo-feng; Bi, Yun-peng; Wang, Bo; Zhao, Yi-min

    2010-01-01

    The aim of this article was to demonstrate a novel approach to designing facial prostheses using the transplantation concept and computer-assisted technology for extensive, large, maxillofacial defects that cross the facial midline. The three-dimensional (3D) facial surface images of a patient and his relative were reconstructed using data obtained through optical scanning. Based on these images, the corresponding portion of the relative's face was transplanted to the patient's where the defect was located, which could not be rehabilitated using mirror projection, to design the virtual facial prosthesis without the eye. A 3D model of an artificial eye that mimicked the patient's remaining one was developed, transplanted, and fit onto the virtual prosthesis. A personalized retention structure for the artificial eye was designed on the virtual facial prosthesis. The wax prosthesis was manufactured through rapid prototyping, and the definitive silicone prosthesis was completed. The size, shape, and cosmetic appearance of the prosthesis were satisfactory and matched the defect area well. The patient's facial appearance was recovered perfectly with the prosthesis, as determined through clinical evaluation. The optical 3D imaging and computer-aided design/computer-assisted manufacturing system used in this study can design and fabricate facial prostheses more precisely than conventional manual sculpturing techniques. The discomfort generally associated with such conventional methods was decreased greatly. The virtual transplantation used to design the facial prosthesis for the maxillofacial defect, which crossed the facial midline, and the development of the retention structure for the eye were both feasible.

  1. Laser-welded titanium frameworks supported by implants in the partially edentulous mandible: a 10-year comparative follow-up study.

    PubMed

    Ortorp, Anders; Jemt, Torsten

    2008-09-01

    Comparative long-term knowledge of different framework materials in the partially edentulous implant patient is not available. To report and compare 10-year data on free-standing implant-supported partial prostheses with laser-welded titanium (test) and conventional gold alloy (control) frameworks. Altogether, 52 partially edentulous patients were consecutively provided with laser-welded prostheses (n = 60) in the partially edentulous lower jaw (test group). A control group of 52 randomly selected patients with gold alloy castings (n = 60) was used for comparison. Clinical and radiographic 10-year data were retrospectively collected and evaluated for both groups. The overall 10-year implant cumulative survival rate (CSR) was 93.0% (loaded implants, 96.4%), with a 10-year implant CSR of 91.5 and 94.7% for test and control implants, respectively (p > .05). Out of a total of 22 lost implants, 17 implants (77.3%) were shorter than 10 mm. The overall 10-year prosthesis CSR was 93.7%, with a corresponding 10-year CSR of 88.4 and 100% for test and control groups, respectively (p < .05). Average 10-year bone loss was 0.46 mm (SD 0.47) and 0.69 mm (SD 0.53) for the test and control groups (p < .001), respectively. Only 1% of the implants had >3 mm accumulated bone loss after 10 years. Altogether, 10 of the prostheses in both groups had implant component mechanical problems (8.3%). None of the frameworks or implants fractured, but more fractures of porcelain veneers were observed in the test group (p < .05). The protocol of implant treatment in the partially edentulous jaw functioned well during 10 years, although prosthodontic maintenance was required. However, laser-welded titanium frameworks presented more problems as compared with gold alloy frameworks. More loaded implants were lost (p < .05), and higher incidence of porcelain chipping was noted in the test group (p < .05). However, bone loss was on an average lower for the test group during the 10 years of follow-up (p < .001).

  2. [The influence of the stapes prosthesis on the long-term results of stapedectomy (author's transl)].

    PubMed

    Schöndorf, J; Pilorget, J; Gräber, S

    1980-05-01

    In comparing two groups of patients following stapedectomies, significantly better long-term results were obtained by using the Robinson steel piston prosthesis (n = 85) as opposed to the wire prosthesis (n = 74). By so doing, the impairment of sound transmission was reduced and the Carhart depression counterbalanced. This improvement is thought to result from the increased mass and stability of the steel prosthesis as well as from its more correct anatomical positioning.

  3. Functional Performance Evaluation of the Northwestern University Flexible Subischial Vacuum (NU-FlexSIV) Socket for Persons with Transfemoral Amputation

    DTIC Science & Technology

    2016-10-01

    satisfaction with device’’ (i.e. prosthesis) than the IC Socket. During year 1, we received all required IRB approvals, registered the clinical... satisfaction with device” (i.e. prosthesis) than the IC Socket. 2. KEYWORDS: Prosthetic Socket, Artificial Limbs, Prosthesis, Transfemoral Amputee, Gait...FlexSIV Socket will result in better quality of life and “ satisfaction with device” (i.e. prosthesis) than the IC socket. Accomplishments under

  4. Categorization of compensatory motions in transradial myoelectric prosthesis users.

    PubMed

    Hussaini, Ali; Zinck, Arthur; Kyberd, Peter

    2017-06-01

    Prosthesis users perform various compensatory motions to accommodate for the loss of the hand and wrist as well as the reduced functionality of a prosthetic hand. Investigate different compensation strategies that are performed by prosthesis users. Comparative analysis. A total of 20 able-bodied subjects and 4 prosthesis users performed a set of bimanual activities. Movements of the trunk and head were recorded using a motion capture system and a digital video recorder. Clinical motion angles were calculated to assess the compensatory motions made by the prosthesis users. The video recording also assisted in visually identifying the compensations. Compensatory motions by the prosthesis users were evident in the tasks performed (slicing and stirring activities) as compared to the benchmark of able-bodied subjects. Compensations took the form of a measured increase in range of motion, an observed adoption of a new posture during task execution, and prepositioning of items in the workspace prior to initiating a given task. Compensatory motions were performed by prosthesis users during the selected tasks. These can be categorized into three different types of compensations. Clinical relevance Proper identification and classification of compensatory motions performed by prosthesis users into three distinct forms allows clinicians and researchers to accurately identify and quantify movement. It will assist in evaluating new prosthetic interventions by providing distinct terminology that is easily understood and can be shared between research institutions.

  5. Aortic annulus eccentricity before and after transcatheter aortic valve implantation: Comparison of balloon-expandable and self-expanding prostheses.

    PubMed

    Schuhbaeck, Annika; Weingartner, Christina; Arnold, Martin; Schmid, Jasmin; Pflederer, Tobias; Marwan, Mohamed; Rixe, Johannes; Nef, Holger; Schneider, Christian; Lell, Michael; Uder, Michael; Ensminger, Stephan; Feyrer, Richard; Weyand, Michael; Achenbach, Stephan

    2015-07-01

    The geometry of the aortic annulus and implanted transcatheter aortic valve prosthesis might influence valve function. We investigated the influence of valve type and aortic valve calcification on post-implant geometry of catheter-based aortic valve prostheses. Eighty consecutive patients with severe aortic valve stenosis (mean age 82 ± 6 years) underwent computed tomography before and after TAVI. Aortic annulus diameters were determined. Influence of prosthesis type and degree of aortic valve calcification on post-implant eccentricity were analysed. Aortic annulus eccentricity was reduced in patients after TAVI (0.21 ± 0.06 vs. 0.08 ± 0.06, p<0.0001). Post-TAVI eccentricity was significantly lower in 65 patients following implantation of a balloon-expandable prosthesis as compared to 15 patients who received a self-expanding prosthesis (0.06 ± 0.05 vs. 0.15 ± 0.07, p<0.0001), even though the extent of aortic valve calcification was not different. After TAVI, patients with a higher calcium amount retained a significantly higher eccentricity compared to patients with lower amounts of calcium. Patients undergoing TAVI with a balloon-expandable prosthesis show a more circular shape of the implanted prosthesis as compared to patients with a self-expanding prosthesis. Eccentricity of the deployed prosthesis is affected by the extent of aortic valve calcification. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Improvements in survival of the uncemented Nottingham Total Shoulder prosthesis: a prospective comparative study

    PubMed Central

    Rosenberg, Nahum; Neumann, Lars; Modi, Amit; Mersich, Istvan J; Wallace, Angus W

    2007-01-01

    Background The uncemented Nottingham Total Shoulder Replacement prosthesis system (Nottingham TSR) was developed from the previous BioModular® shoulder prosthesis taking into consideration the causes of the initial implant's failure. We investigated the impact of changes in the design of Nottingham TSR prosthesis on its survivorship rate. Methods Survivorship analyses of three types of uncemented total shoulder arthroplasty prostheses (BioModular®, initial Nottingham TSR and current Nottingham TSR systems with 11, 8 and 4 year survivorship data respectively) were compared. All these prostheses were implanted for the treatment of disabling pain in the shoulder due to primary and secondary osteoarthritis or rheumatoid arthritis. Each type of the prosthesis studied was implanted in consecutive group of patients – 90 patients with BioModular® system, 103 with the initial Nottingham TSR and 34 patients with the current Nottingham TSR system. The comparison of the annual cumulative survivorship values in the compatible time range between the three groups was done according to the paired t test. Results The 8-year and 11-year survivorship rates for the initially used modified BioModular® uncemented prosthesis were relatively low (75.6% and 71.7% respectively) comparing to the reported survivorship of the conventional cemented implants. The 8-year survivorship for the uncemented Nottingham TSR prosthesis was significantly higher (81.8%), but still not in the desired range of above 90%, that is found in other cemented designs. Glenoid component loosening was the main factor of prosthesis failure in both prostheses and mainly occurred in the first 4 postoperative years. The 4-year survivorship of the currently re-designed Nottingham TSR prosthesis, with hydroxylapatite coating of the glenoid baseplate, was significantly higher, 93.1% as compared to 85.1% of the previous Nottingham TSR. Conclusion The initial Nottingham shoulder prosthesis showed significantly higher survivorship than the BioModular® uncemented prosthesis, but lower than expected. Subsequently re-designed Nottingham TSR system presented a high short term survivorship rate that encourages its ongoing use PMID:17683577

  7. Experience with the use of a partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft.

    PubMed

    Birk, Stephanie; Brase, Christoph; Hornung, Joachim

    2014-08-01

    In the further development of alloplastic prostheses for use in middle ear surgery, the Dresden and Cologne University Hospitals, working together with a company, introduced a new partial ossicular replacement prosthesis in 2011. The ball-and-socket joint between the prosthesis and the shaft mimics the natural articulations between the malleus and incus and between the incus and stapes, allowing reaction to movements of the tympanic membrane graft, particularly during the healing process. Retrospective evaluation To reconstruct sound conduction as part of a type III tympanoplasty, partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft was implanted in 60 patients, with other standard partial ossicular replacement prosthesis implanted in 40 patients and 64 patients. Pure-tone audiometry was carried out, on average, 19 and 213 days after surgery. Results of the partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft were compared with those of the standard prostheses. Early measurements showed a mean improvement of 3.3 dB in the air-bone gap (ABG) with the partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft, giving similar results than the standard implants (6.6 and 6.0 dB, respectively), but the differences were not statistically significant. Later measurements showed a statistically significant improvement in the mean ABG, 11.5 dB, compared with 4.4 dB for one of the standard partial ossicular replacement prosthesis and a tendency of better results to 6.9 dB of the other standard prosthesis. In our patients, we achieved similarly good audiometric results to those already published for the partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft. Intraoperative fixation posed no problems, and the postoperative complication rate was low.

  8. Comparative experimental re-evaluation of the two implanting methods of silicone gel testicular prostheses in beagle dogs

    PubMed Central

    2011-01-01

    Background Testicular prosthesis has been applied clinically for decades, and implantation of testis prosthesis under the tunica albuginea has been considered to be the standard method in the most of the reports. However, postoperative scrotal appearance, the mobilization and the palpitation of the prosthesis are not always satisfactory to all the patients. Modifications in surgical techniques might be necessary to bring improvements to the clinical outcomes in testicular prosthesis implantation. Findings In a group of 9 beagle dogs in this study, an orchiectomy succeeded with a testicular prosthesis implantation under the tunica vaginalis, and a complete mechanical denudation of the testicular parenchyma succeeded with an implantation under the tunica albuginea were performed, respectively. Histopathological evaluations of the scrotal tissues and the implants, which were made at the end of the follow-up, showed that all the tested animals lived uneventful lives during the follow-up period, and no rejections or infections were found. Prostheses implanted under the tunica vaginalis showed a more satisfying mobilization and palpation than those implanted under the tunica albuginea. Chronic inflammation in the para-prosthesis tissues with vascular proliferation and fibrinogenesis were more common in the "under tunica albuginea" group than that in the "under tunica vaginalis" group, although differences in fibrinogenesis between the two groups were found to be statistically insignificant. Conclusions In this comparative study, we have re-evaluated the two most popular implantation methods of testicular prosthesis, the "under the tunica albuginea" and the "under the tunica vaginalis" pathways, in animal models. We found that the testicular prosthesis were all well tolerated, but the prosthesis implanted under the tunica vaginalis showed a more satisfying result concerning appearance, palpability, and histopathological findings than that of the "under the tunica albuginea" group. The "under the tunica vaginalis" method might become a more practical method for future testicular prosthesis implantation. PMID:21457571

  9. [Imaging evaluation on adaptability of proximal humeral anatomy after shoulder replacement with individualized shoulder prosthesis].

    PubMed

    Shi, Youxing; Tang, Kanglai; Yuan, Chengsong; Tao, Xu; Wang, Huaqing; Chen, Bo; Guo, Yupeng

    2015-03-24

    Modern shoulder prosthesis has evolved through four generations. And the fourth generation technology has a core three-dimensional design of restoring 3D reconstruction of proximal humeral anatomy. Thus a new shoulder prosthesis is developed on the basis of the technology of 3D prosthesis. Assessment of whether shoulder prosthesis can restore individualized reconstruction of proximal humeral anatomy is based on the adaptability of proximal humeral anatomy. To evaluate the adaptability of proximal humeral anatomy through measuring the parameters of proximal humeral anatomy after shoulder replacement with individualized shoulder prosthesis and compare with normal data. The parameters of proximal humeral anatomy were analyzed and evaluated for a total of 12 cases undergoing shoulder replacement with individualized shoulder prosthesis. The relevant anatomical parameters included neck-shaft angle (NSA), retroversion angle (RA), humeral head height (HH) and humeral head diameter (HD). And the anatomical parameters were compared with the data from normal side. All underwent shoulder replacement with individualized shoulder prosthesis. The postoperative parameters of proximal humeral anatomy were compared with those of normal side. And the difference of NSA was < 3°, RA < 3°, HH < 3 mm and HD < 2 mm. And paired-sample t test was used to study the parameters of proximal humeral anatomy between postoperative and normal side. The normal and postoperative NSA was (140.2 ± 6.8)° and (139.5 ± 6.6)° respectively, RA (34.4 ± 3.3)° and (33.8-3.1)°, HH (15.3 ± 2.1) mm and (14.6+0.9) mm, HW (42.2 ± 2.82) mm and (41.8 ± 2.33) mm respectively. No significant difference existed between two groups (P > 0.05). Individualized shoulder prosthesis has excellent adaptability to shoulder. All core parameters are freely adjustable and specification models may be optimized. With matching tools, individualized shoulder prosthesis improves the accuracy and reliability in shoulder replacement.

  10. Evaluation of direct and indirect additive manufacture of maxillofacial prostheses.

    PubMed

    Eggbeer, Dominic; Bibb, Richard; Evans, Peter; Ji, Lu

    2012-09-01

    The efficacy of computer-aided technologies in the design and manufacture of maxillofacial prostheses has not been fully proven. This paper presents research into the evaluation of direct and indirect additive manufacture of a maxillofacial prosthesis against conventional laboratory-based techniques. An implant/magnet-retained nasal prosthesis case from a UK maxillofacial unit was selected as a case study. A benchmark prosthesis was fabricated using conventional laboratory-based techniques for comparison against additive manufactured prostheses. For the computer-aided workflow, photogrammetry, computer-aided design and additive manufacture (AM) methods were evaluated in direct prosthesis body fabrication and indirect production using an additively manufactured mould. Qualitative analysis of position, shape, colour and edge quality was undertaken. Mechanical testing to ISO standards was also used to compare the silicone rubber used in the conventional prosthesis with the AM material. Critical evaluation has shown that utilising a computer-aided work-flow can produce a prosthesis body that is comparable to that produced using existing best practice. Technical limitations currently prevent the direct fabrication method demonstrated in this paper from being clinically viable. This research helps prosthesis providers understand the application of a computer-aided approach and guides technology developers and researchers to address the limitations identified.

  11. [The endo-exo femur prosthesis--a new concept of bone-guided, prosthetic rehabilitation following above-knee amputation].

    PubMed

    Aschoff, H H; Clausen, A; Hoffmeister, T

    2009-01-01

    The implantation of an intramedullary transcutaneously conducted femur prosthesis presents a rather new procedure for the rehabilitation of above-knee amputated patients. The aim of the so-called endo-exo prosthesis is to avoid the well-known problems at the interface between the sleeve of the prosthesis and the soft tissue coat of the femur stump which often impedes an inconspicuous and harmonic gait. The company ERSKA Implants in Lübeck/Germany has developed an intramedullary femur prosthesis with a spongiosa metal-configurated relief surface which, when implanted cementless, enables a secure osseointegration and allows a more direct transmission of muscle power to the lower leg prosthesis. A minimum length of 16-18 cm and a sufficient soft tissue coverage of the femur stump is needed. The problems at the perforation point of the implant through the soft tissue coat can be handled or even be avoided and they do not necessarily provoke an intramedullary infection. We report on 30 cases that were operated between 1999 and 2008. The design of the prosthesis, aspects of the operative procedure and latest results are presented.

  12. Evaluation of a new composite prosthesis for the repair of abdominal wall defects.

    PubMed

    Losi, Paola; Munaò, Antonella; Spiller, Dario; Briganti, Enrica; Martinelli, Ilaria; Scoccianti, Marco; Soldani, Giorgio

    2007-10-01

    The degree of integration of biomaterials used in the repair of abdominal wall defects seems to depend upon the structure of the prosthesis. The present investigation evaluates the behaviour in terms of adhesion formation and integration of a new composite prosthesis that could be employed in this clinical application. Full-thickness abdominal wall defects (7 x 5 cm) were created in 16 anaesthetized New Zealand white rabbits and the prosthesis were placed in direct contact with the visceral peritoneum during the experiment. The defects were repaired with a composite prosthesis or pure polypropylene mesh to establish two study groups (n = 8 each). The composite device was constituted by a polypropylene mesh physically attached to a poly(ether)urethane-polydimethylsiloxane laminar sheet. Animals were sacrificed 7, 14, 21 and 30 days after implant and prosthesis/surrounding tissue specimens subjected to light and electron microscopy. Firm adhesions were detected in the polypropylene implants, while they were not present in the composite implants. The excellent behaviour of the composite prosthesis shown in this study warrants further investigation on its use for the repair of abdominal wall defects when a prosthetic device needs to be placed in contact with the intestinal loops.

  13. Linking of total elbow prosthesis during surgery; a biomechanical analysis.

    PubMed

    De Vos, Maarten J; Wagener, Marc L; Hendriks, Jan C M; Eygendaal, Denise; Verdonschot, Nico

    2013-09-01

    Presently, 2 types of elbow prostheses are used: unlinked and linked. The Latitude total elbow prosthesis allows the surgeon to decide during the implantation whether the prosthesis is placed unlinked or linked, and whether the native radial head is retained, resected, or replaced. The purpose of this study is to assess and to compare the varus and valgus laxity of the unlinked and linked version of the latitude total elbow prosthesis with: (1) the native radial head preserved, (2) the native radial head excised, and (3) the native radial head replaced by a radial head component. Biomechanical testing was performed on 14 fresh-frozen upper limb specimens. Linking the prosthesis predominantly influences the valgus laxity of the elbow. Linking the Latitude total elbow prosthesis results in increased valgus stability. In the linked version of the total elbow prosthesis, the radial head only plays a small part in both valgus and varus stability. An unlinked situation is not advised in absence of a native radial head or in case of inability to replace the radial head. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  14. [Osseointegration as a method of direct stabilization of amputation prostheses to the bone].

    PubMed

    Rochmiński, Robert; Sibński, Marcin; Synder, Marek

    2011-01-01

    This article summarizes important advantages, disadvantages and the process of treatment of patients after lower limb amputation on the level of the femur, with osseointegrated prosthesis. In the process of treatment bone-integrated material is implanted to the femur, with allows for structural and functional connection between live tissue and the prosthesis. This solution allows the patient for easy usage and direct steerage of the prosthesis, transferring of body weight to the floor and detection of sensation in the moment of contact between prosthesis and the ground. Osseointegrated prostheses in the femur gives the opportunity not to use the traditional solutions and socket-related problems as: mobility difficulties, skin sores, rush, pain during weight bearing, temporary changes of the stump volume, difficulty donning the prosthesis, unreliability of prosthesis being securely suspended. Osseointegration is possible even in cases, when quality of skin and short stump enables to use the traditional prosthetic socket. It is used after lower and upper limbs amputations. This kind of prosthetic solutions has some disadvantages and limitations. It is expensive and demanding. It can be used in cooperative patients, who take active part in the process of implantation, rehabilitation and in future usage if the prosthesis.

  15. "Bail out" procedures for malpositioning of aortic valve prosthesis (CoreValve).

    PubMed

    Vavouranakis, Manolis; Vrachatis, Dimitrios A; Toutouzas, Konstantinos P; Chrysohoou, Christina; Stefanadis, Christodoulos

    2010-11-05

    Two techniques for correcting malpositioning occurring during percutaneous aortic valve replacement (PAVR) with the CoreValve ReValving™ System are described in this article. The "Removing and Reinserting Technique" was used in 2 patients, in whom the prosthesis was positioned too high. The "Snare Technique" was used in 1 patient, in whom the prosthesis was implanted too low. In all patients the aortic valve prosthesis was successfully re-implanted. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  16. A fiber-reinforced composite prosthesis restoring a lateral midfacial defect: a clinical report.

    PubMed

    Kurunmäki, Hemmo; Kantola, Rosita; Hatamleh, Muhanad M; Watts, David C; Vallittu, Pekka K

    2008-11-01

    This clinical report describes the use of a glass fiber-reinforced composite (FRC) substructure to reinforce the silicone elastomer of a large facial prosthesis. The FRC substructure was shaped into a framework and embedded into the silicone elastomer to form a reinforced facial prosthesis. The prosthesis is designed to overcome the disadvantages associated with traditionally fabricated prostheses; namely, delamination of the silicone of the acrylic base, poor marginal adaptation over time, and poor simulation of facial expressions.

  17. Negative Gauge Pressure Moisture Management and Secure Adherence Device for Prosthetic Limbs

    DTIC Science & Technology

    2013-03-01

    prosthesis feels like it is sliding up and down or falling off when I am active. D. I have been more active than normal as a result of this prosthesis ...temperature. 3. My prosthesis feels like it is sliding up and down or falling off when I am active. 4. I have been more active than normal as a result of...objective of this research was to develop and test a novel prosthesis incorporating a negative gauge pressure moisture management and secure

  18. Development and Application of a Tendon Prosthesis for Early Functional Restoration of the Hand.

    DTIC Science & Technology

    1975-09-01

    F’A-AOk 322 JEFFERSON MEDICAL COLL PHILADELPHIA PA F/B 6/5 DEVELOPMENT AND APPLICATION OF A TENDON PROSTHESIS FOR EARLY FU--ETC(U) SEP 75 J M HUNTER...LEVEL INVENTORY DEELOPKWTI AND APPLICATION OF A TENDON PROSTHESIS FOR EARLY FUNCTIOKAL RESTORATION OF THE RAND BIDETICATION DISTRIBUTION STATEMENT A...AND RETURN TO DTIC-DDA-2 FORM DOCUMENT PROCESSING SHEETCToc 79 0 AD DEVELOPNDT AND APPLICATION OF A TENDOR PROSTHESIS FOR EARLY FUNCTIONAL

  19. Feasibility study of the production of biomedical Ti-6Al-4V alloy by powder metallurgy.

    PubMed

    Bolzoni, L; Ruiz-Navas, E M; Gordo, E

    2015-04-01

    Titanium and its alloys are characterized by an exceptional combination of properties like high strength, good corrosion resistance and biocompatibility which makes them suitable materials for biomedical prosthesis and devices. The wrought Ti-6Al-4V alloy is generally favored in comparison to other metallic biomaterials due to its relatively low elastic modulus and it has been long used to obtain products for biomedical applications. In this work an alternative route to fabricate biomedical implants made out of the Ti-6Al-4V alloy is investigated. Specifically, the feasibility of the conventional powder metallurgy route of cold uniaxial pressing and sintering is addressed by considering two types of powders (i.e. blended elemental and prealloyed). The characterization of physical properties, chemical analysis, mechanical behavior and microstructural analysis is carried out in-depth and the properties are correlated among them. On the base of the results found, the produced alloys are promising materials for biomedical applications as well as cheaper surgical devices and tools. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Surgical anatomy and pathology of the middle ear.

    PubMed

    Luers, Jan Christoffer; Hüttenbrink, Karl-Bernd

    2016-02-01

    Middle ear surgery is strongly influenced by anatomical and functional characteristics of the middle ear. The complex anatomy means a challenge for the otosurgeon who moves between preservation or improvement of highly important functions (hearing, balance, facial motion) and eradication of diseases. Of these, perforations of the tympanic membrane, chronic otitis media, tympanosclerosis and cholesteatoma are encountered most often in clinical practice. Modern techniques for reconstruction of the ossicular chain aim for best possible hearing improvement using delicate alloplastic titanium prostheses, but a number of prosthesis-unrelated factors work against this intent. Surgery is always individualized to the case and there is no one-fits-all strategy. Above all, both middle ear diseases and surgery can be associated with a number of complications; the most important ones being hearing deterioration or deafness, dizziness, facial palsy and life-threatening intracranial complications. To minimize risks, a solid knowledge of and respect for neurootologic structures is essential for an otosurgeon who must train him- or herself intensively on temporal bones before performing surgery on a patient. © 2015 Anatomical Society.

  1. Fitting a hand-glove prosthesis to enhance the reconstructed mutilated hand.

    PubMed

    Leow, M E; Kour, A K; Pereira, B P; Pho, R W

    1998-03-01

    Microsurgical reconstruction of the severely mutilated hand aimed at improving prehensile functions often does not address the esthetic aspects of the hand. The poor appearance of the reconstructed hand affects its active display and use. A hand-glove prosthesis may be prescribed in this instance to enhance the overall form and function of the mutilated hand. We reviewed 16 cases of mutilating hand injuries in which surgical reconstructions were performed and the patients were subsequently fitted with a hand-glove prosthesis to augment the outcome. An improved appearance was achieved in all patients fitted with the prosthesis. The patients' sense of confidence was also enhanced, which in turn promoted the active and open use of the reconstructed hands. While prescribed primarily to improve the appearance of the reconstructed hands, these prostheses were documented to enhance the physical hand functions in 11 cases by increasing the span of the hand and providing an opposable post and a palmar base for holding and for anchorage. The prosthesis enhanced assistive functions of the reconstructed hands and freed the contralateral normal hand for use in bimanual activities, such as holding a wallet and taking out money, supporting a note pad for writing, and holding a plate at buffet receptions. At the 18-month follow-up visit, 13 (87%) of the patients continued to use their prosthesis. Wear and tear were problems associated with the frequent use of the prosthesis. The expected life span of the prosthesis with daily use ranged from 2 to 3 years. All the patients acknowledged that the prosthesis played a role in their rehabilitation and that it helped them to overcome the initial psychological trauma and to come to terms with their physical loss.

  2. Kinematic analysis of a posterior-stabilized knee prosthesis.

    PubMed

    Zhao, Zhi-Xin; Wen, Liang; Qu, Tie-Bing; Hou, Li-Li; Xiang, Dong; Bin, Jia

    2015-01-20

    The goal of total knee arthroplasty (TKA) is to restore knee kinematics. Knee prosthesis design plays a very important role in successful restoration. Here, kinematics models of normal and prosthetic knees were created and validated using previously published data. Computed tomography and magnetic resonance imaging scans of a healthy, anticorrosive female cadaver were used to establish a model of the entire lower limbs, including the femur, tibia, patella, fibula, distal femur cartilage, and medial and lateral menisci, as well as the anterior cruciate, posterior cruciate, medial collateral, and lateral collateral ligaments. The data from the three-dimensional models of the normal knee joint and a posterior-stabilized (PS) knee prosthesis were imported into finite element analysis software to create the final kinematic model of the TKA prosthesis, which was then validated by comparison with a previous study. The displacement of the medial/lateral femur and the internal rotation angle of the tibia were analyzed during 0-135° flexion. Both the output data trends and the measured values derived from the normal knee's kinematics model were very close to the results reported in a previous in vivo study, suggesting that this model can be used for further analyses. The PS knee prosthesis underwent an abnormal forward displacement compared with the normal knee and has insufficient, or insufficiently aggressive, "rollback" compared with the lateral femur of the normal knee. In addition, a certain degree of reverse rotation occurs during flexion of the PS knee prosthesis. There were still several differences between the kinematics of the PS knee prosthesis and a normal knee, suggesting room for improving the design of the PS knee prosthesis. The abnormal kinematics during early flexion shows that the design of the articular surface played a vital role in improving the kinematics of the PS knee prosthesis.

  3. An integrated CAD/CAM/robotic milling method for custom cementless femoral prostheses.

    PubMed

    Wen-ming, Xi; Ai-min, Wang; Qi, Wu; Chang-hua, Liu; Jian-fei, Zhu; Fang-fang, Xia

    2015-09-01

    Aseptic loosening is the primary cause of cementless femoral prosthesis failure and is related to the primary stability of the cementless femoral prosthesis in the femoral cavity. The primary stability affects both the osseointegration and the long-term stability of cementless femoral prostheses. A custom cementless femoral prosthesis can improve the fit and fill of the prosthesis in the femoral cavity and decrease the micromotion of the proximal prosthesis such that the primary stability of the custom prosthesis can be improved, and osseointegration of the proximal prosthesis is achieved. These results will help to achieve long-term stability in total hip arthroplasty (THA). In this paper, we introduce an integrated CAD/CAM/robotic method of milling custom cementless femoral prostheses. The 3D reconstruction model uses femoral CT images and 3D design software to design a CAD model of the custom prosthesis. After the transformation matrices between two units of the robotic system are calibrated, consistency between the CAM software and the robotic system can be achieved, and errors in the robotic milling can be limited. According to the CAD model of the custom prosthesis, the positions of the robotic tool points are produced by the CAM software of the CNC machine. The normal vector of the three adjacent robotic tool point positions determines the pose of the robotic tool point. In conclusion, the fit rate of custom pig femur stems in the femoral cavities was 90.84%. After custom femoral prostheses were inserted into the femoral cavities, the maximum gaps between the prostheses and the cavities measured less than 1 mm at the diaphysis and 1.3 mm at the metaphysis. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  4. Survival of various implant-supported prosthesis designs following 36 months of clinical function.

    PubMed

    Rodriguez, A M; Orenstein, I H; Morris, H F; Ochi, S

    2000-12-01

    The use of endosseous dental implants to replace natural teeth lost to trauma, dental caries, or periodontal disease has become a predictable form of prosthetic treatment since gaining popularity in the early 1980s. While numerous clinical studies have focused on the survival of implants, few address the survival of different prosthesis designs. Beginning in 1991, 882 prostheses supported by more than 2,900 implants (687 patients) were placed by the Department of Veterans Affairs Dental Implant Clinical Research Group (DICRG). These prostheses were divided into five research strata based on arch location. The recommended design for each stratum was: bar-supported overdenture (maxillary completely edentulous); screw-retained hybrid denture (mandibular completely edentulous); screw-retained fixed partial denture (mandibular and maxillary posterior partially edentulous); and cemented single crown (maxillary anterior single tooth). Alternative overdenture designs were utilized in the edentulous arches when the recommended prosthesis could not be fabricated. Prosthesis success rates for the research strata were calculated for an observation time of up to 36 months following prosthesis placement. Success rates for the maxillary edentulous stratum ranged from 94.6% for the bar-retained overdenture supported by five to six fixtures to 81.8% for the cap-retained overdenture. The mandibular edentulous strata produced success rates of 98.1% for the fixed hybrid prosthesis to 91.7% for the cap-retained prosthesis. Success rates for maxillary and mandibular posterior fixed partial dentures were 94.3% and 92.6%, respectively, while the maxillary anterior single-tooth prosthesis yielded a success rate of 98.1% for the 36-month observation period. The recommended prosthesis designs investigated in this study proved to be reliable, with encouraging success rates for an observation period of 36 months following placement.

  5. Next generation shape memory prosthesis (NiTiBOND) for stapedotomy: Short-term results.

    PubMed

    Green, J Douglas; McElveen, John T

    2017-04-01

    To review hearing results and complications for the NiTiBOND next generation shape memory prosthesis and compare them with results for the current shape memory prosthesis (SMart). Retrospective, multicenter chart review. Primary laser stapedotomy was performed using either a NiTiBOND or a SMart prosthesis. Ninety-two ears in 79 patients were included in the study (67.4% female), 52 with the NiTiBOND prosthesis and 40 with the SMart prosthesis. Data collected included demographic variables, pre- and postoperative pure-tone air and bone conduction thresholds, speech discrimination scores, complications, and the need for revision surgery. Pure-tone average (PTA) and PTA air-bone gap (ABG) pre- and postoperative were computed. Success was defined as a postoperative ABG of ≤10 dB. There were no significant differences between groups in hearing results, including improvement in ABG, change in speech discrimination, change in air or bone PTA, or change in high-frequency bone PTA. Short-term (mean = 4.4 and 4.9 weeks, respectively) success rates for the NiTiBOND and SMart prostheses were 84.6% and 70.0%, respectively, with this difference closing at the most recent test (83.7% and 80.0%, respectively). No revision surgery took place in either group, and there were no differences in complications such as dizziness, tinnitus, or taste disturbance, though the NiTiBOND group tended to have a lower rate of transient or permanent vertigo. Compared with the SMart prosthesis, the NiTiBOND prosthesis is a safe prosthesis that achieves at least comparable hearing results and may offer some surgical advantages. 4 Laryngoscope, 127:915-920, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  6. Metabolics of stair ascent with a powered transfemoral prosthesis.

    PubMed

    Ledoux, E D; Lawson, B E; Shultz, A H; Bartlett, H L; Goldfarb, M

    2015-01-01

    This paper evaluates the effectiveness of a powered knee and ankle prosthesis for stair ascent through a metabolic assessment comparing energy expenditure of a single transfemoral amputee subject while ascending stairs with the powered prosthesis relative to his passive daily use device, as well as comparing the kinematics and kinetics obtained with the passive prosthesis to healthy biomechanics. The subject wore a portable system that measured pulmonary gaseous exchange rates of oxygen and carbon dioxide while he ascended stairs with each of the prostheses in alternating tests. The results indicated that the amputee's energy expenditure decreased by 32 percent while climbing with the powered prosthesis as compared to his passive one, and the kinematics and kinetics achieved were representative of healthy biomechanics.

  7. Prosthetic Rehabilitation of Mandibular Defects with Fixed-removable Partial Denture Prosthesis Using Precision Attachment: A Twin Case Report.

    PubMed

    Munot, Vimal Kantilal; Nayakar, Ramesh P; Patil, Raghunath

    2017-01-01

    The restoration of normal function and esthetic appearance with a dental prosthesis is a major challenge in the rehabilitation of patients who have lost their teeth and surrounding bone because of surgery for oral cyst or tumor. Rehabilitation with fixed or removable prosthesis is even more challenging when the edentulous span is long and the ridge is defective. Anatomic deformities and unfavorable biomechanics encountered in the region of resection add to the misery. In such situation, a fixed-removable prosthesis allows favorable biomechanical stress distribution along with restoration of esthetics, phonetics, comfort, hygiene, and better postoperative care and maintenance. This article describes rehabilitation of two cases with mandibular defects with an attachment-retained fixed-removable hybrid prosthesis.

  8. 21 CFR 876.3750 - Testicular prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Testicular prosthesis. 876.3750 Section 876.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Prosthetic Devices § 876.3750 Testicular prosthesis. (a...

  9. Development of Subischial Prosthetic Sockets with Vacuum-Assisted Suspension for Highly Active Persons with Transfemoral Amputations

    DTIC Science & Technology

    2012-10-01

    materials to facilitate dissemination of this technique. 15. SUBJECT TERMS Transfemoral amputation, sub-ischial socket, prosthesis , vacuum-assisted...an appropriate mechanical pump to create suitable vacuum for suspension of the prosthesis ...sockets of highly active prosthesis users

  10. 21 CFR 878.3610 - Esophageal prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Esophageal prosthesis. 878.3610 Section 878.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3610 Esophageal prosthesis...

  11. 21 CFR 878.3610 - Esophageal prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Esophageal prosthesis. 878.3610 Section 878.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3610 Esophageal prosthesis...

  12. 21 CFR 878.3610 - Esophageal prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Esophageal prosthesis. 878.3610 Section 878.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3610 Esophageal prosthesis...

  13. 21 CFR 878.3610 - Esophageal prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Esophageal prosthesis. 878.3610 Section 878.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3610 Esophageal prosthesis...

  14. 21 CFR 878.3610 - Esophageal prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Esophageal prosthesis. 878.3610 Section 878.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3610 Esophageal prosthesis...

  15. An interim prosthesis program for lower limb amputees: comparison of public and private models of service.

    PubMed

    Gordon, Robert; Magee, Christopher; Frazer, Anna; Evans, Craig; McCosker, Kathryn

    2010-06-01

    This study compared the outcomes of an interim mechanical prosthesis program for lower limb amputees operated under a public and private model of service. Over a two-year period, 60 transtibial amputees were fitted with an interim prosthesis as part of their early amputee care. Thirty-four patients received early amputee care under a public model of service, whereby a prosthetist was employed to provide the interim mechanical prosthesis service. The remaining 26 patients received early amputee care under a private model of service, where an external company was contracted to provide the interim mechanical prosthesis service. The results suggested comparable clinical outcomes between the two patient groups. However, the public model appeared to be less expensive with the average labour cost per patient being 29.0% lower compared with the private model. The results suggest that a public model of service may provide a more comprehensive and less expensive interim prosthesis program for lower limb amputees.

  16. A clinical and radiostereometric study of the cemented PFC-sigma prosthesis: a 5-year study of 29 cases with a fixed bearing.

    PubMed

    von Schewelov, Thord; Besjakov, Jack; Sanzén, Lennart; Carlsson, Ake

    2009-07-01

    The press-fit condylar (PFC) cruciate-retaining total knee prosthesis is well documented in the literature. In 1997, a modification of the femoral component was introduced, and the prosthesis was renamed PFC-Sigma. The alteration may influence the migratory and rotational pattern of the tibial component and thus long-time survival rate. In this radiostereometric analysis, we found that the micromotion of the PFC-Sigma prosthesis differs slightly from the original PFC design, an advantage of the PFC-Sigma prosthesis. The median maximum total point motion at 5 years was 0.64 mm for the PFC-Sigma design and 0.79 mm for the previous version of PFC (P = .9). However, the PFC-Sigma rotated less around the transverse (x) axis than did the PFC (medians, 0.22 mm and 0.48 mm, respectively; P = .04). From the radiostereometric, radiographic, and clinical data, we conclude that the PFC-Sigma knee prosthesis can be used with confidence.

  17. Gingival Retraction Methods for Fabrication of Fixed Partial Denture: Literature Review

    PubMed Central

    S, Safari; Ma, Vossoghi Sheshkalani; Mi, Vossoghi Sheshkalani; F, Hoseini Ghavam; M, Hamedi

    2016-01-01

    Fixed dental prosthesis success requires appropriate impression taking of the prepared finish line. This is critical in either tooth supported fixed prosthesis (crown and bridge) or implant supported fixed prosthesis (solid abutment). If the prepared finish line is adjacent to the gingival sulcus, gingival retraction techniques should be used to decrease the marginal discrepancy among the restoration and the prepared abutment. Accurate marginal positioning of the restoration in the prepared finish line of the abutment is required for therapeutic, preventive and aesthetic purposes. In this article, conventional and modern methods of gingival retraction in the fixed tooth supported prosthesis and fixed implant supported prosthesis are expressed. PubMed and Google Scholar databases were searched manually for studies on gingival tissue managements prior to impression making in fixed dental prosthesis since 1975. Conclusions were extracted and summarized. Keywords were impression making, gingival retraction, cordless retraction, and implant. Gingival retraction techniques can be classified as mechanical, chemical or surgical. In this article, different gingival management techniques are discussed. PMID:28959744

  18. Gingival Retraction Methods for Fabrication of Fixed Partial Denture: Literature Review.

    PubMed

    S, Safari; Ma, Vossoghi Sheshkalani; Mi, Vossoghi Sheshkalani; F, Hoseini Ghavam; M, Hamedi

    2016-06-01

    Fixed dental prosthesis success requires appropriate impression taking of the prepared finish line. This is critical in either tooth supported fixed prosthesis (crown and bridge) or implant supported fixed prosthesis (solid abutment). If the prepared finish line is adjacent to the gingival sulcus, gingival retraction techniques should be used to decrease the marginal discrepancy among the restoration and the prepared abutment. Accurate marginal positioning of the restoration in the prepared finish line of the abutment is required for therapeutic, preventive and aesthetic purposes. In this article, conventional and modern methods of gingival retraction in the fixed tooth supported prosthesis and fixed implant supported prosthesis are expressed. PubMed and Google Scholar databases were searched manually for studies on gingival tissue managements prior to impression making in fixed dental prosthesis since 1975. Conclusions were extracted and summarized. Keywords were impression making, gingival retraction, cordless retraction, and implant. Gingival retraction techniques can be classified as mechanical, chemical or surgical. In this article, different gingival management techniques are discussed.

  19. Sensory feedback add-on for upper-limb prostheses.

    PubMed

    Fallahian, Nader; Saeedi, Hassan; Mokhtarinia, Hamidreza; Tabatabai Ghomshe, Farhad

    2017-06-01

    Sensory feedback systems have been of great interest in upper-limb prosthetics. Despite tremendous research, there are no commercial modality-matched feedback systems. This article aims to introduce the first detachable and feedback add-on option that can be attached to in-use prostheses. A sensory feedback system was tested on a below-elbow myoelectric prosthesis. The aim was to have the amputee grasp fragile objects without crushing while other accidental feedback sources were blocked. A total of 8 successful trials (out of 10) showed that sensory feedback system decreased the amputee's visual dependency by improving awareness of his prosthesis. Sensory feedback system can be used either as post-fabrication (prosthetic add-on option) or para-fabrication (incorporated into prosthetic design). The use of these direct feedback systems can be explored with a current prosthesis before ordering new high-tech prosthesis. Clinical relevance This technical note introduces the first attach/detach-able sensory feedback system that can simply be added to in-use (myo)electric prosthesis, with no obligation to change prosthesis design or components.

  20. Nontraumatic Fracture of the Femoral Condylar Prosthesis in a Total Knee Arthroplasty Leading to Mechanical Failure

    PubMed Central

    Swamy, Girish N.; Quah, Conal; Bagouri, Elmunzar; Badhe, Nitin P.

    2014-01-01

    This paper reports a case of fatigue fracture of the femoral component in a cruciate-retaining cemented total knee arthroplasty (TKA). A 64-year-old man had undergone a primary TKA for osteoarthritis 10 years previously at another institution using the PFC-Sigma prosthesis. The patient recovered fully and was back to his regular activities. He presented with a history of sudden onset pain and locking of the left knee since the preceding three months. There was no history of trauma, and the patient was mobilizing with difficulty using crutches. Radiographs revealed fracture of the posterior condyle of the femoral prosthesis. Revision surgery was performed as an elective procedure revealing the broken prosthesis. The TC3RP-PFC revision prosthesis was used with a medial parapatellar approach. The patient recovered fully without any squeal. Mechanical failure of the knee arthroplasty prosthesis is rare, and nontraumatic fracture of the femoral metallic component has not been reported before. PMID:24587928

  1. Nontraumatic fracture of the femoral condylar prosthesis in a total knee arthroplasty leading to mechanical failure.

    PubMed

    Swamy, Girish N; Quah, Conal; Bagouri, Elmunzar; Badhe, Nitin P

    2014-01-01

    This paper reports a case of fatigue fracture of the femoral component in a cruciate-retaining cemented total knee arthroplasty (TKA). A 64-year-old man had undergone a primary TKA for osteoarthritis 10 years previously at another institution using the PFC-Sigma prosthesis. The patient recovered fully and was back to his regular activities. He presented with a history of sudden onset pain and locking of the left knee since the preceding three months. There was no history of trauma, and the patient was mobilizing with difficulty using crutches. Radiographs revealed fracture of the posterior condyle of the femoral prosthesis. Revision surgery was performed as an elective procedure revealing the broken prosthesis. The TC3RP-PFC revision prosthesis was used with a medial parapatellar approach. The patient recovered fully without any squeal. Mechanical failure of the knee arthroplasty prosthesis is rare, and nontraumatic fracture of the femoral metallic component has not been reported before.

  2. Laryngeal complications after type 1 thyroplasty.

    PubMed

    Cotter, C S; Avidano, M A; Crary, M A; Cassisi, N J; Gorham, M M

    1995-12-01

    Type I thyroplasty has become a primary surgical choice for voice restoration in patients with glottal incompetence. This study examines factors associated with laryngeal complications after type I thyroplasty. Ten laryngoscopic variables were analyzed from preoperative, intraoperative, and postoperative videolaryngoscopies of 51 patients undergoing 58 medialization procedures. Ten patient and operative variables were examined by medical record review. Major complications were defined as wound hemorrhage, airway obstruction, or prosthesis extrusion. Minor complications were defined as vocal fold hematoma without airway obstruction or prosthesis movement. The major complication rate was 8.6%, and the minor complication rate was 29%. No delayed hemorrhage or airway obstruction occurred. Prosthesis extrusion occurred in five (8.6%) patients 1 week to 5 months after surgery. Extrusion was associated with suboptimal prosthesis placement in 80% of cases. Two patients retained excellent glottal closure despite extrusion. Vocal fold hematoma was identified in 14 (24%) cases and resolved within 1 week. Prosthesis movement occurred in three (5%) patients 1 week to 6 months after surgery and resulted in poor glottal closure. All patients with prosthesis extrusion or movement were female. Type I thyroplasty remains a safe outpatient procedure with few major complications. Prosthesis extrusion was associated with suboptimal prosthesis placement and may or may not result in poor glottal closure. Minor vocal fold hematomas were relatively frequent, resolved rapidly, and were not associated with airway obstruction. Female patients may be more prone to complications because of their small laryngeal size.

  3. Implications of prosthesis funding structures on the use of prostheses: experiences of individuals with upper limb absence.

    PubMed

    Biddiss, Elaine; McKeever, Patricia; Lindsay, Sally; Chau, Tom

    2011-06-01

    While sparsely researched, funding structures may play an important role in use of and satisfaction with prostheses and related health services. The objectives of this study were to (1) quantify the direct costs of prosthesis wear, (2) explore variations in funding distribution, and (3) describe the role of affordability in prosthesis selection and wear. An anonymous, online cross-sectional descriptive survey was administered. Analyses were conducted of qualitative and quantitative data extracted from an international sample of 242 individuals with upper limb absence. Access to prosthesis funding was variable and fluctuated with age, level of limb absence and country of care. Of individuals who gave details on prosthetic costs, 63% (n = 69) were fully reimbursed for their prosthetic expenses, while 37% (n = 40) were financially disadvantaged by the cost of components (mean [SD] US$9,574 [$9,986]) and their ongoing maintenance (US$1,936 [$3,179]). Of the 71 non-wearers in this study, 48% considered cost an influential factor in their decision not to adopt prosthesis use. Prosthesis funding is neither homogeneous nor transparent and can be influential in both the selection and use of a prosthetic device. Inequitable access to prosthesis funding is evident in industrialized nations and may lead to prosthesis abandonment and/or diminished quality of life for individuals with upper limb absences. Increased efforts are required to ensure equitable access to upper limb prosthetics and related services in line with individuals' needs.

  4. Mobile-bearing TKA improved the anteroposterior joint stability in mid-flexion range comparing to fixed-bearing TKA.

    PubMed

    Minoda, Yukihide; Ikebuchi, Mitsuhiko; Mizokawa, Shigekazu; Ohta, Yoichi; Nakamura, Hiroaki

    2016-11-01

    Proper anteroposterior (AP) joint displacement is an important indicator of good clinical outcome following total knee arthroplasty (TKA). We hypothesized that a newly introduced mobile-bearing posterior stabilized (PS) prosthesis reduces the AP joint displacement. The aim of this study is to compare the AP joint displacement between a newly introduced mobile-bearing PS TKA in one knee and a conventional fixed-bearing PS TKA in other knee. 82 knees in 41 patients who had bilateral TKAs were investigated. All the patients received a conventional fixed-bearing PS prosthesis in one knee and a highly congruent mobile-bearing PS prosthesis in the other knee. AP joint displacement was measured using the KT-2000 arthrometer, at 30° and 75° in flexion, at average of 3.3 years after the operation. AP joint displacements at 30° in flexion were 6 ± 3 mm in the knees with the mobile-bearing PS prosthesis and 9 ± 4 mm in the knee with fixed-bearing PS prosthesis (p < 0.001). AP joint displacements at 75° in flexion were 4 ± 2 mm in the knees with the mobile-bearing PS prosthesis and 6 ± 3 mm in the knee with fixed-bearing PS prosthesis (p < 0.001). This study suggested that the design of the prosthesis can improve the AP joint stability in mid-flexion range.

  5. 21 CFR 888.3220 - Finger joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Finger joint metal/polymer constrained cemented... metal/polymer constrained cemented prosthesis. (a) Identification. A finger joint metal/polymer..., 1996 for any finger joint metal/polymer constrained cemented prosthesis that was in commercial...

  6. 21 CFR 888.3220 - Finger joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Finger joint metal/polymer constrained cemented... metal/polymer constrained cemented prosthesis. (a) Identification. A finger joint metal/polymer..., 1996 for any finger joint metal/polymer constrained cemented prosthesis that was in commercial...

  7. 21 CFR 888.3025 - Passive tendon prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Passive tendon prosthesis. 888.3025 Section 888.3025 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3025 Passive tendon prosthesis. (a...

  8. 21 CFR 888.3025 - Passive tendon prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Passive tendon prosthesis. 888.3025 Section 888.3025 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3025 Passive tendon prosthesis. (a...

  9. 21 CFR 888.3025 - Passive tendon prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Passive tendon prosthesis. 888.3025 Section 888.3025 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3025 Passive tendon prosthesis. (a...

  10. 21 CFR 888.3220 - Finger joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Finger joint metal/polymer constrained cemented... metal/polymer constrained cemented prosthesis. (a) Identification. A finger joint metal/polymer..., 1996 for any finger joint metal/polymer constrained cemented prosthesis that was in commercial...

  11. 21 CFR 888.3220 - Finger joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Finger joint metal/polymer constrained cemented... metal/polymer constrained cemented prosthesis. (a) Identification. A finger joint metal/polymer..., 1996 for any finger joint metal/polymer constrained cemented prosthesis that was in commercial...

  12. 21 CFR 888.3220 - Finger joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Finger joint metal/polymer constrained cemented... metal/polymer constrained cemented prosthesis. (a) Identification. A finger joint metal/polymer..., 1996 for any finger joint metal/polymer constrained cemented prosthesis that was in commercial...

  13. 21 CFR 872.3960 - Mandibular condyle prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Mandibular condyle prosthesis. 872.3960 Section 872.3960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3960 Mandibular condyle prosthesis. (a...

  14. 21 CFR 872.3950 - Glenoid fossa prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Glenoid fossa prosthesis. 872.3950 Section 872.3950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3950 Glenoid fossa prosthesis. (a) Identification...

  15. 21 CFR 878.3680 - Nose prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nose prosthesis. 878.3680 Section 878.3680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3680 Nose prosthesis. (a...

  16. 21 CFR 878.3550 - Chin prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Chin prosthesis. 878.3550 Section 878.3550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3550 Chin prosthesis. (a...

  17. 21 CFR 878.3720 - Tracheal prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Tracheal prosthesis. 878.3720 Section 878.3720 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3720 Tracheal prosthesis. (a...

  18. 21 CFR 878.3750 - External prosthesis adhesive.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false External prosthesis adhesive. 878.3750 Section 878.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3750 External prosthesis...

  19. 21 CFR 878.3750 - External prosthesis adhesive.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false External prosthesis adhesive. 878.3750 Section 878.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3750 External prosthesis...

  20. 21 CFR 878.3550 - Chin prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Chin prosthesis. 878.3550 Section 878.3550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3550 Chin prosthesis. (a...

  1. 21 CFR 878.3750 - External prosthesis adhesive.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External prosthesis adhesive. 878.3750 Section 878.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3750 External prosthesis...

  2. 21 CFR 878.3550 - Chin prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Chin prosthesis. 878.3550 Section 878.3550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3550 Chin prosthesis. (a...

  3. 21 CFR 878.3550 - Chin prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Chin prosthesis. 878.3550 Section 878.3550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3550 Chin prosthesis. (a...

  4. 21 CFR 878.3550 - Chin prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Chin prosthesis. 878.3550 Section 878.3550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3550 Chin prosthesis. (a...

  5. 21 CFR 878.3680 - Nose prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nose prosthesis. 878.3680 Section 878.3680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3680 Nose prosthesis. (a...

  6. 21 CFR 878.3750 - External prosthesis adhesive.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false External prosthesis adhesive. 878.3750 Section 878.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3750 External prosthesis...

  7. 21 CFR 878.3680 - Nose prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nose prosthesis. 878.3680 Section 878.3680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3680 Nose prosthesis. (a...

  8. 21 CFR 878.3680 - Nose prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nose prosthesis. 878.3680 Section 878.3680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3680 Nose prosthesis. (a...

  9. 21 CFR 878.3680 - Nose prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nose prosthesis. 878.3680 Section 878.3680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3680 Nose prosthesis. (a...

  10. 21 CFR 878.3750 - External prosthesis adhesive.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false External prosthesis adhesive. 878.3750 Section 878.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3750 External prosthesis...

  11. 21 CFR 888.3210 - Finger joint metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Finger joint metal/metal constrained cemented... metal/metal constrained cemented prosthesis. (a) Identification. A finger joint metal/metal constrained..., 1996 for any finger joint metal/metal constrained cemented prosthesis that was in commercial...

  12. 21 CFR 888.3210 - Finger joint metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Finger joint metal/metal constrained cemented... metal/metal constrained cemented prosthesis. (a) Identification. A finger joint metal/metal constrained..., 1996 for any finger joint metal/metal constrained cemented prosthesis that was in commercial...

  13. 21 CFR 888.3200 - Finger joint metal/metal constrained uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Finger joint metal/metal constrained uncemented... metal/metal constrained uncemented prosthesis. (a) Identification. A finger joint metal/metal... Administration on or before December 26, 1996 for any finger joint metal/metal constrained uncemented prosthesis...

  14. 21 CFR 888.3200 - Finger joint metal/metal constrained uncemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Finger joint metal/metal constrained uncemented... metal/metal constrained uncemented prosthesis. (a) Identification. A finger joint metal/metal... Administration on or before December 26, 1996 for any finger joint metal/metal constrained uncemented prosthesis...

  15. 21 CFR 888.3100 - Ankle joint metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ankle joint metal/composite semi-constrained... Ankle joint metal/composite semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/composite semi-constrained cemented prosthesis is a device intended to be implanted to replace an...

  16. 21 CFR 888.3490 - Knee joint femorotibial metal/composite non-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Knee joint femorotibial metal/composite non... § 888.3490 Knee joint femorotibial metal/composite non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/composite non-constrained cemented prosthesis is a device...

  17. 21 CFR 888.3500 - Knee joint femorotibial metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Knee joint femorotibial metal/composite semi... § 888.3500 Knee joint femorotibial metal/composite semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/composite semi-constrained cemented prosthesis is a two-part...

  18. 21 CFR 888.3550 - Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Knee joint patellofemorotibial polymer/metal/metal... § 888.3550 Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis. (a) Identification. A knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis is a device...

  19. Facial recognition using enhanced pixelized image for simulated visual prosthesis.

    PubMed

    Li, Ruonan; Zhhang, Xudong; Zhang, Hui; Hu, Guanshu

    2005-01-01

    A simulated face recognition experiment using enhanced pixelized images is designed and performed for the artificial visual prosthesis. The results of the simulation reveal new characteristics of visual performance in an enhanced pixelization condition, and then new suggestions on the future design of visual prosthesis are provided.

  20. 21 CFR 888.3510 - Knee joint femorotibial metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/polymer constrained... Knee joint femorotibial metal/polymer constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer constrained cemented prosthesis is a device intended to be implanted to replace part...

  1. 21 CFR 888.3565 - Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellofemorotibial metal/polymer... Devices § 888.3565 Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis. (a) Identification. A knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis is a device...

  2. 21 CFR 888.3530 - Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/polymer semi... § 888.3530 Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer semi-constrained cemented prosthesis is a device intended...

  3. 21 CFR 888.3660 - Shoulder joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Shoulder joint metal/polymer semi-constrained... Shoulder joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A shoulder joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a...

  4. 21 CFR 888.3540 - Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellofemoral polymer/metal semi... § 888.3540 Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis. (a) Identification. A knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis is a two-part...

  5. 21 CFR 888.3550 - Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellofemorotibial polymer/metal/metal... § 888.3550 Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis. (a) Identification. A knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis is a device...

  6. 21 CFR 888.3650 - Shoulder joint metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Shoulder joint metal/polymer non-constrained... Shoulder joint metal/polymer non-constrained cemented prosthesis. (a) Identification. A shoulder joint metal/polymer non-constrained cemented prosthesis is a device intended to be implanted to replace a...

  7. 21 CFR 888.3530 - Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Knee joint femorotibial metal/polymer semi... § 888.3530 Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer semi-constrained cemented prosthesis is a device intended...

  8. 21 CFR 888.3680 - Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Shoulder joint glenoid (hemi-shoulder) metallic... Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis. (a) Identification. A shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis is a device that has a glenoid (socket) component...

  9. 21 CFR 888.3690 - Shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Shoulder joint humeral (hemi-shoulder) metallic... Shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis. (a) Identification. A shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis is a device made of alloys, such as cobalt-chromium...

  10. 21 CFR 888.3680 - Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Shoulder joint glenoid (hemi-shoulder) metallic... Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis. (a) Identification. A shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis is a device that has a glenoid (socket) component...

  11. 21 CFR 888.3690 - Shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Shoulder joint humeral (hemi-shoulder) metallic... Shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis. (a) Identification. A shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis is a device made of alloys, such as cobalt-chromium...

  12. 21 CFR 888.3680 - Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Shoulder joint glenoid (hemi-shoulder) metallic... Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis. (a) Identification. A shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis is a device that has a glenoid (socket) component...

  13. 21 CFR 888.3680 - Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Shoulder joint glenoid (hemi-shoulder) metallic... Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis. (a) Identification. A shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis is a device that has a glenoid (socket) component...

  14. 21 CFR 888.3690 - Shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Shoulder joint humeral (hemi-shoulder) metallic... Shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis. (a) Identification. A shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis is a device made of alloys, such as cobalt-chromium...

  15. 21 CFR 888.3680 - Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Shoulder joint glenoid (hemi-shoulder) metallic... Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis. (a) Identification. A shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis is a device that has a glenoid (socket) component...

  16. 21 CFR 888.3690 - Shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Shoulder joint humeral (hemi-shoulder) metallic... Shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis. (a) Identification. A shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis is a device made of alloys, such as cobalt-chromium...

  17. 21 CFR 888.3690 - Shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Shoulder joint humeral (hemi-shoulder) metallic... Shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis. (a) Identification. A shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis is a device made of alloys, such as cobalt-chromium...

  18. 21 CFR 888.3500 - Knee joint femorotibial metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/composite semi... § 888.3500 Knee joint femorotibial metal/composite semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/composite semi-constrained cemented prosthesis is a two-part...

  19. 21 CFR 888.3100 - Ankle joint metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ankle joint metal/composite semi-constrained... Ankle joint metal/composite semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/composite semi-constrained cemented prosthesis is a device intended to be implanted to replace an...

  20. 21 CFR 888.3490 - Knee joint femorotibial metal/composite non-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/composite non... § 888.3490 Knee joint femorotibial metal/composite non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/composite non-constrained cemented prosthesis is a device...

  1. 21 CFR 888.3565 - Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Knee joint patellofemorotibial metal/polymer... Devices § 888.3565 Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis. (a) Identification. A knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis is a device...

  2. 21 CFR 888.3565 - Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Knee joint patellofemorotibial metal/polymer... Devices § 888.3565 Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis. (a) Identification. A knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis is a device...

  3. 21 CFR 888.3550 - Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Knee joint patellofemorotibial polymer/metal/metal... § 888.3550 Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis. (a) Identification. A knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis is a device...

  4. 21 CFR 888.3530 - Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Knee joint femorotibial metal/polymer semi... § 888.3530 Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer semi-constrained cemented prosthesis is a device intended...

  5. 21 CFR 888.3530 - Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Knee joint femorotibial metal/polymer semi... § 888.3530 Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer semi-constrained cemented prosthesis is a device intended...

  6. 21 CFR 888.3530 - Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Knee joint femorotibial metal/polymer semi... § 888.3530 Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer semi-constrained cemented prosthesis is a device intended...

  7. 21 CFR 888.3565 - Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Knee joint patellofemorotibial metal/polymer... Devices § 888.3565 Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis. (a) Identification. A knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis is a device...

  8. 21 CFR 888.3550 - Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Knee joint patellofemorotibial polymer/metal/metal... § 888.3550 Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis. (a) Identification. A knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis is a device...

  9. 21 CFR 888.3550 - Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Knee joint patellofemorotibial polymer/metal/metal... § 888.3550 Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis. (a) Identification. A knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis is a device...

  10. Development of Sub-Ischial Prosthetic Sockets with Vacuum-Assisted Suspension for Highly Active Persons with Transfemoral Amputations

    DTIC Science & Technology

    2013-10-01

    15. SUBJECT TERMS Transfemoral amputation, sub-ischial socket, prosthesis , vacuum-assisted suspension 16. SECURITY CLASSIFICATION OF: 17...vacuum for suspension of the prosthesis ...14 Task 6 Determine range of volumes to be evacuated from transfemoral sockets of highly active prosthesis users

  11. 21 CFR 878.3590 - Ear prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ear prosthesis. 878.3590 Section 878.3590 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3590 Ear prosthesis. (a) Identification. An...

  12. 21 CFR 878.3590 - Ear prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ear prosthesis. 878.3590 Section 878.3590 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3590 Ear prosthesis. (a) Identification. An...

  13. 21 CFR 878.3590 - Ear prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ear prosthesis. 878.3590 Section 878.3590 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3590 Ear prosthesis. (a) Identification. An...

  14. 21 CFR 878.3590 - Ear prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ear prosthesis. 878.3590 Section 878.3590 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3590 Ear prosthesis. (a) Identification. An...

  15. 21 CFR 878.3590 - Ear prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ear prosthesis. 878.3590 Section 878.3590 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3590 Ear prosthesis. (a) Identification. An...

  16. 21 CFR 888.6 - Degree of constraint.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... replacement and prevents dislocation of the prosthesis in more than one anatomic plane and consists of either... translation and rotation of the prosthesis in one or more planes via the geometry of its articulating surfaces... total joint replacement and restricts minimally prosthesis movement in one or more planes. Its...

  17. Prosthetic Rehabilitation of Mandibular Defects with Fixed-removable Partial Denture Prosthesis Using Precision Attachment: A Twin Case Report

    PubMed Central

    Munot, Vimal Kantilal; Nayakar, Ramesh P.; Patil, Raghunath

    2017-01-01

    The restoration of normal function and esthetic appearance with a dental prosthesis is a major challenge in the rehabilitation of patients who have lost their teeth and surrounding bone because of surgery for oral cyst or tumor. Rehabilitation with fixed or removable prosthesis is even more challenging when the edentulous span is long and the ridge is defective. Anatomic deformities and unfavorable biomechanics encountered in the region of resection add to the misery. In such situation, a fixed-removable prosthesis allows favorable biomechanical stress distribution along with restoration of esthetics, phonetics, comfort, hygiene, and better postoperative care and maintenance. This article describes rehabilitation of two cases with mandibular defects with an attachment-retained fixed-removable hybrid prosthesis. PMID:29042738

  18. Design of a power-asymmetric actuator for a transtibial prosthesis.

    PubMed

    Bartlett, Harrison L; Lawson, Brian E; Goldfarb, Michael

    2017-07-01

    This paper presents the design and characterization of a power-asymmetric actuator for a transtibial prosthesis. The device is designed to provide the combination of: 1) joint locking, 2) high power dissipation, and 3) low power generation. This actuator functionality allows for a prosthesis to be designed with minimal mass and power consumption relative to a fully-powered robotic prosthesis while maintaining much of the functionality necessary for activities of daily living. The actuator achieves these design characteristics while maintaining a small form factor by leveraging a combination of electromechanical and hydraulic components. The design of the actuator is described herein, and results of an experimental characterization are provided that indicate that the actuator is capable of providing the functional capabilities required of an ankle prosthesis in a compact and lightweight package.

  19. Consumer design priorities for upper limb prosthetics.

    PubMed

    Biddiss, Elaine; Beaton, Dorcas; Chau, Tom

    2007-11-01

    To measure consumer satisfaction with upper limb prosthetics and provide an enumerated list of design priorities for future developments. A self-administered, anonymous survey collected information on participant demographics, history of and goals for prosthesis use, satisfaction, and design priorities. The questionnaire was available online and in paper format and was distributed through healthcare providers, community support groups, and one prosthesis manufacturer; 242 participants of all ages and levels of upper limb absence completed the survey. Rates of rejection for myoelectric hands, passive hands, and body-powered hooks were 39%, 53%, and 50%, respectively. Prosthesis wearers were generally satisfied with their devices while prosthesis rejecters were dissatisfied. Reduced prosthesis weight emerged as the highest priority design concern of consumers. Lower cost ranked within the top five design priorities for adult wearers of all device types. Life-like appearance is a priority for passive/cosmetic prostheses, while improved harness comfort, wrist movement, grip control and strength are required for body-powered devices. Glove durability, lack of sensory feedback, and poor dexterity were also identified as design priorities for electric devices. Design priorities reflect consumer goals for prosthesis use and vary depending on the type of prosthesis used and age. Future design efforts should focus on the development of more light-weight, comfortable prostheses.

  20. Rehabilitation of a missing ear with an implant retained auricular prosthesis

    PubMed Central

    Guttal, Satyabodh Sheshraj; Shanbhag, Shruti; Kulkarni, Sudhindra S.; Thakur, Srinath L.

    2015-01-01

    Burns can leave a patient with a severely debilitating disability even after treatment. The objectives of burn rehabilitation are to minimize the adverse effects caused by the injury while rehabilitating the patient's physical and psychological well-being, maximizing social integration. Long-term success of maxillofacial prostheses mainly depends on the retention. Extra oral implant retained prostheses have proved to be a predictable treatment option for maxillofacial rehabilitation. Replacement of a severely deformed external ear with burned tissues may be satisfactorily accomplished by a cosmetic prosthesis anchored by implants integrated in the skull. The use of such implants is now a well-recognized method for creating a stable result in maxillofacial rehabilitation. This case report describes a safe, simple and economical method for the rehabilitation of a patient with missing right auricle using an implant supported silicone prosthesis. The implant was placed in the mastoid region of the temporal bone. Reconstruction of the ear was done with auricular silicone prosthesis, retained using magnets incorporated in an autopolymerizing resin shim to decrease the weight of the prosthesis on a single implant. This method eliminates the need of tedious laboratory procedures and exact casting and fitting requirements of a metal substructure while minimizing the overall weight and cost of the prosthesis while maintaining adequate support, esthetics and retention of the prosthesis. PMID:26929490

  1. Tracheal replacement in rabbits with a new composite silicone-metallic prosthesis.

    PubMed

    Dodge-Khatami, Ali; Niessen, Hans W M; Koole, Leo H; Klein, Marloes G; van Gulik, Thomas M; de Mol, Bas A J M

    2003-09-01

    A new composite silicone-metallic prosthesis was tested, studying the potential for respiratory epithelial covering over the biocompatible inner lining, in a rabbit survival model. Seven New Zealand White rabbits underwent near-total excision of their trachea and implantation of a sterile prosthesis. After 2 months, they were sacrificed and the prostheses were retrieved. Specimens were fixed and histologically examined for tissue reaction around the prosthesis, at the anastomotic lines, and particularly for the presence or absence of epithelialization of the inner lumen over the biocompatible surface. All rabbits survived the operation. At 2 months, the outer layer of the prosthesis was consistently covered with fibrosis and neutrophils. The inner layer showed necrotic cells and scant re-epithelialization over the biocompatible lining, up to 5 mm beyond the anastomosis, with no evidence of organized respiratory epithelium in the middle sections. The new prosthesis is a viable temporary solution for airway replacement in rabbits. Granulation tissue was not observed at the anastomosis, and re-epithelialization did occur, but failed to achieve full-length luminal covering. The potential for granulation tissue does not yet make this an ideal long-term solution. Improvements in prosthesis design or biocompatibility are required, and need to be re-evaluated before applicability for chronic use.

  2. Design and Characterization of a Quasi-Passive Pneumatic Foot-Ankle Prosthesis.

    PubMed

    Lee, Jeffrey D; Mooney, Luke M; Rouse, Elliott J

    2017-07-01

    The majority of commercially available passive prosthetic feet are not capable of providing joint mechanics that match that of the intact human ankle. Due to their cantilever design, their stiffness characteristics contrast with what has been observed in the biological ankle, namely, an increase in stiffness during the stance phase of walking. In this paper, we introduce the design and control of a pneumatic foot-ankle prosthesis that attempts to provide biomimetic mechanics. The prosthesis is comprised of a pneumatic cylinder in series with a fiberglass leaf spring, and a solenoid valve to control the flow of air between the two sides of the cylinder. The solenoid valve acts as a mechanical clutch, enabling resetting of the ankle's equilibrium position. By adjusting the pressure inside the cylinder, the prosthesis can be customized to provide a range of ankle mechanics. A mechanical testing machine is used to compare the torque-angle curve of the pneumatic prosthesis with a low-profile passive prosthetic foot. Finally, data are presented of one transtibial amputee walking with the prosthesis at 1.2 m/s. The testing shows that the pneumatic prosthesis is capable of providing an appropriate range of motion as well a maximum torque of 94 Nm, while returning approximately 11.5 J of energy.

  3. Developing an Ear Prosthesis Fabricated in Polyvinylidene Fluoride by a 3D Printer with Sensory Intrinsic Properties of Pressure and Temperature

    PubMed Central

    Suaste-Gómez, Ernesto; Rodríguez-Roldán, Grissel; Reyes-Cruz, Héctor; Terán-Jiménez, Omar

    2016-01-01

    An ear prosthesis was designed in 3D computer graphics software and fabricated using a 3D printing process of polyvinylidene fluoride (PVDF) for use as a hearing aid. In addition, the prosthesis response to pressure and temperature was observed. Pyroelectric and piezoelectric properties of this ear prosthesis were investigated using an astable multivibrator circuit, as changes in PVDF permittivity were observed according to variations of pressure and temperature. The results show that this prosthesis is reliable for use under different conditions of pressure (0 Pa to 16,350 Pa) and temperature (2 °C to 90 °C). The experimental results show an almost linear and inversely proportional behavior between the stimuli of pressure and temperature with the frequency response. This 3D-printed ear prosthesis is a promising tool and has a great potentiality in the biomedical engineering field because of its ability to generate an electrical potential proportional to pressure and temperature, and it is the first time that such a device has been processed by the additive manufacturing process (3D printing). More work needs to be carried out to improve the performance, such as electrical stimulation of the nervous system, thereby extending the purpose of a prosthesis to the area of sensory perception. PMID:26959026

  4. Developing an Ear Prosthesis Fabricated in Polyvinylidene Fluoride by a 3D Printer with Sensory Intrinsic Properties of Pressure and Temperature.

    PubMed

    Suaste-Gómez, Ernesto; Rodríguez-Roldán, Grissel; Reyes-Cruz, Héctor; Terán-Jiménez, Omar

    2016-03-04

    An ear prosthesis was designed in 3D computer graphics software and fabricated using a 3D printing process of polyvinylidene fluoride (PVDF) for use as a hearing aid. In addition, the prosthesis response to pressure and temperature was observed. Pyroelectric and piezoelectric properties of this ear prosthesis were investigated using an astable multivibrator circuit, as changes in PVDF permittivity were observed according to variations of pressure and temperature. The results show that this prosthesis is reliable for use under different conditions of pressure (0 Pa to 16,350 Pa) and temperature (2 °C to 90 °C). The experimental results show an almost linear and inversely proportional behavior between the stimuli of pressure and temperature with the frequency response. This 3D-printed ear prosthesis is a promising tool and has a great potentiality in the biomedical engineering field because of its ability to generate an electrical potential proportional to pressure and temperature, and it is the first time that such a device has been processed by the additive manufacturing process (3D printing). More work needs to be carried out to improve the performance, such as electrical stimulation of the nervous system, thereby extending the purpose of a prosthesis to the area of sensory perception.

  5. Interdisciplinary interface between fixed prosthodontics and periodontics.

    PubMed

    Abduo, Jaafar; Lyons, Karl M

    2017-06-01

    Although periodontal factors do not usually have a direct effect on the survival of a fixed prosthesis, harmony between the prosthesis and the periodontium is critical otherwise esthetics, the longevity of the prosthesis and the periodontium will be compromised. A close interdisciplinary relationship between periodontics and prosthodontics is therefore necessary to avoid an unsatisfactory treatment outcome, requiring extensive and expensive retreatment. The design of the prosthesis, the number and quality of the abutment teeth, the preparation and the pontic, the occlusion and the material need to be considered when planning prosthodontic treatment. The location of the preparation margin and the contour and emergence profile of the prosthesis will influence the response of the gingival tissues to the prosthesis. Pontic design and cleansibility also contribute to the response of the gingival tissues as well as to the clinical and esthetic outcome. Even an optimal pontic design will not prevent inflammation of the mucosa adjacent to the pontic if pontic hygiene is not maintained by removal of plaque. Case selection and the patients' ability to carry out adequate oral hygiene are therefore essential for longevity of the prosthesis, and regular reviews provide an opportunity for early detection and treatment of failures. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Design and experimental analysis of a new malleovestibulopexy prosthesis using a finite element model of the human middle ear.

    PubMed

    Vallejo Valdezate, Luis A; Hidalgo Otamendi, Antonio; Hernández, Alberto; Lobo, Fernando; Gil-Carcedo Sañudo, Elisa; Gil-Carcedo García, Luis M

    2015-01-01

    Many designs of prostheses are available for middle ear surgery. In this study we propose a design for a new prosthesis, which optimises mechanical performance in the human middle ear and improves some deficiencies in the prostheses currently available. Our objective was to design and assess the theoretical acoustic-mechanical behaviour of this new total ossicular replacement prosthesis. The design of this new prosthesis was based on an animal model (an iguana). For the modelling and mechanical analysis of the new prosthesis, we used a dynamic 3D computer model of the human middle ear, based on the finite elements method (FEM). The new malleovestibulopexy prosthesis design demonstrates an acoustical-mechanical performance similar to that of the healthy human middle ear. This new design also has additional advantages, such as ease of implantation and stability in the middle ear. This study shows that computer simulation can be used to design and optimise the vibroacoustic characteristics of middle ear implants and demonstrates the effectiveness of a new malleovestibulopexy prosthesis in reconstructing the ossicular chain. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.

  7. Advanced engineering tools for design and fabrication of a custom nasal prosthesis

    NASA Astrophysics Data System (ADS)

    Oliveira, Inês; Leal, Nuno; Silva, Pedro; da Costa Ferreira, A.; Neto, Rui J.; Lino, F. Jorge; Reis, Ana

    2012-09-01

    Unexpected external defects resulting from neoplasms, burns, congenital malformations, trauma or other diseases, particularly when involving partial or total loss of an external organ, can be emotionally devastating. These defects can be restored with prosthesis, obtained by different techniques, materials and methods. The increase of patient numbers and cost constraints lead to the need of exploring new techniques that can increase efficiency. The main goal of this project was to develop a full engineering-based manufacturing process to obtain soft-tissue prosthesis that could provide faster and less expensive options in the manufacturing of customized prosthesis, and at the same time being able to reproduce the highest degree of details, with the maximum comfort for the patient. Design/methodology/approach - This case report describes treatment using silicone prosthesis with an anatomic retention for an 80-years-old woman with a rhinectomy. The proposed methodology integrates non-contact structured light scanning, CT and reverse engineering with CAD/CAM and additive manufacturing technology. Findings - The proposed protocol showed encouraging results since reveals being a better solution for fabricating custom-made facial prostheses for asymmetrical organs than conventional approaches. The process allows the attainment of prosthesis with the minimum contact and discomfort for the patient, disclosing excellent results in terms of aesthetic, prosthesis retention and in terms of time and resources consumed.

  8. Biomechanical Analysis of a Novel Intercalary Prosthesis for Humeral Diaphyseal Segmental Defect Reconstruction.

    PubMed

    Zhao, Li-Ming; Tian, Dong-Mu; Wei, Yue; Zhang, Jun-Hui; Di, Zheng-Lin; He, Zhi-Yong; Hu, Yong-Cheng

    2018-02-01

    To study the biomechanical properties of a novel modular intercalary prosthesis for humeral diaphyseal segmental defect reconstruction, to establish valid finite element humerus and prosthesis models, and to analyze the biomechanical differences in modular intercalary prostheses with or without plate fixation. Three groups were set up to compare the performance of the prosthesis: intact humerus, humerus-prosthesis and humerus-prosthesis-plate. The models of the three groups were transferred to finite element software. Boundary conditions, material properties, and mesh generation were set up for both the prosthesis and the humerus. In addition, 100 N or 2 N.m torsion was loaded to the elbow joint surface with the glenohumeral joint surface fixed. Humeral finite element models were established according to CT scans of the cadaveric bone; reverse engineering software Geomagic was used in this procedure. Components of prosthetic models were established using 3-D modeling software Solidworks. To verify the finite element models, the in vitro tests were simulated using a mechanical testing machine (Bionix; MTS Systems Corporation, USA). Starting with a 50 N preload, the specimen was subjected to 5 times tensile (300 N) and torsional (5 N.m) strength; interval time was 30 min to allow full recovery for the next specimen load. Axial tensile and torsional loads were applied to the elbow joint surface to simulate lifting heavy objects or twisting something, with the glenohumeral joint surface fixed. Stress distribution on the humerus did not change its tendency notably after reconstruction by intercalary prosthesis whether with or without a plate. The special design which included a plate and prosthesis effectively diminished stress on the stem where aseptic loosening often takes place. Stress distribution major concentrate upon two stems without plate addition, maximum stress on proximal and distal stem respectively diminish 27.37% and 13.23% under tension, 10.66% and 11.16% under torsion after plate allied. The novel intercalary prosthesis has excellent ability to reconstruct humeral diaphyseal defects. The accessory fixation system, which included a plate and prosthesis, improved the rigidity of anti-tension and anti-torsion, and diminished the risk of prosthetic loosening and dislocation. A finite element analysis is a kind of convenient and practicable method to be used as the confirmation of experimental biomechanics study. © 2018 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  9. Effect of joining the sectioned implant-supported prosthesis on the peri-implant strain generated in simulated mandibular model.

    PubMed

    Singh, Ipsha; Nair, K Chandrasekharan; Shetty, Jayakar

    2017-01-01

    The aim of this study is to evaluate the strain developed in simulated mandibular model before and after the joining of an implant-supported screw-retained prosthesis by different joining techniques, namely, arc welding, laser welding, and soldering. A specimen simulating a mandibular edentulous ridge was fabricated in heat-cured acrylic resin. 4-mm holes were drilled in the following tooth positions; 36, 33, 43, 46. Implant analogs were placed in the holes. University of California, Los Angeles, abutment was attached to the implant fixture. Eight strain gauges were attached to the acrylic resin model. Six similar models were made. Implant-supported screw-retained fixed prosthesis was fabricated in nickel-chromium alloy. A load of 400 N was applied on the prosthesis using universal testing machine. Resultant strain was measured in each strain gauge. All the prostheses were sectioned at the area between 36 and 33, 33 and 43, and 43 and 46 using 35 micrometer carborundum disc, and strain was measured in each strain gauge after applying a load of 400 N on the prosthesis. Specimens were joined by arc welding, soldering, and laser welding. After joining, a load of 400 N was applied on each prosthesis and the resultant strain was measured in each strain gauge. Highest mean strain values were recorded before sectioning of the prostheses (889.9 microstrains). Lowest mean strain values were recorded after sectioning the prosthesis and before reuniting it (225.0 microstrains). Sectioning and reuniting the long-span implant prosthesis was found to be a significant factor in influencing the peri-implant strain.

  10. Sexual Function and Quality of Life Before and After Penile Prosthesis Implantation Following Radial Forearm Flap Phalloplasty.

    PubMed

    Young, Ezekiel E; Friedlander, Daniel; Lue, Kathy; Anele, Uzoma A; Khurgin, Jacob L; Bivalacqua, Trinity J; Burnett, Arthur L; Redett, Richard J; Gearhart, John P

    2017-06-01

    To provide sexual function and quality of life outcomes in patients with severe penile deficiency who underwent radial forearm flap phalloplasty with and without penile prosthesis implantation. Patients with history of severe penile deficiency who underwent microsurgical radial forearm flap phalloplasty with and without penile prosthesis implantation between 2007 and 2014 were identified. They completed a set of web-based validated questionnaires including the International Index of Erectile Function, the Pediatric Penile Perception Score, the Sexual Quality of Life for Men, and several items addressing general quality of life. Outcomes were compared between groups. Nine of the 12 identified patients who had prosthesis after phalloplasty and 4 out of the 7 phalloplasty-only patients completed the survey, resulting in an overall response rate of 68%. Among the phalloplasty-prosthesis patients, 66% reported current sexual activity and 78% reported regular masturbation, whereas 1 of the 4 phalloplasty-only patients reported both. Prosthesis patients scored notably higher in all domains of the International Index of Erectile Function except for sexual desire. In contrast, they demonstrated similar scores of penile perception, as well as general and sexual quality of life. Among patients who have undergone flap phalloplasty, the subsequent placement of penile prosthesis appears to effectively allow for both intercourse and masturbation, resulting in measurable improvements in orgasmic function, intercourse satisfaction, and overall sexual satisfaction. Despite these important benefits, prosthesis placement does not appear to result in improvements in penile perception scores, or general or sexual quality of life. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. The Evolution and Utility of the Small-Carrion Prosthesis, Its Impact, and Progression to the Modern-Day Malleable Penile Prosthesis.

    PubMed

    Martinez, Daniel R; Terlecki, Ryan; Brant, William O

    2015-11-01

    Erectile dysfunction has plagued humanity for millennia. For years, treatment had been in the hands of mental health professionals. It was not until the 1970s that urologists created a modality that was marketable, reproducible, and consistently successful at treating impotence, the Small-Carrion Penile Prosthesis. We present the evolution of the malleable/semi-rigid penile prosthesis, concentrating our efforts reviewing and critiquing the pivotal article published by Drs. Michael P. Small, Hernan M. Carrion, and Julian A. Gordon. We then discuss its continued advancement, current-day utilization, and the future of the malleable prosthesis. From the early 1900s, surgeons have been toying with the idea of creating a penile implant. These initial attempts utilized rib cartilage, and eventually synthetic materials, including acrylic, silicone, and polyethylene. In 1975, Drs. Carrion and Small presented their initial experience of 31 patients utilizing their silicone implant. In their manuscript titled, "The Small-Carrion Penile Prosthesis: New Implant for the Management of Impotence," they discuss their technique, perioperative management of complications, and results. The malleable penile prosthesis continued to evolve throughout the years to the current day Genesis and Spectra. Although the current market is dominated by the inflatable penile prosthesis, there are specific situations where the malleable is ideally utilized. The pivotal article by Drs. Carrion and Small helped pave the way for the "New Era" of penile prosthetics and still remains one of the most impactful contributions to the management of erectile dysfunction. © 2015 International Society for Sexual Medicine.

  12. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint (hemi-hip) acetabular metal cemented... (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip) acetabular metal cemented prosthesis is a device intended to be implanted to replace a portion of the hip joint...

  13. 21 CFR 888.3310 - Hip joint metal/polymer constrained cemented or uncemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint metal/polymer constrained cemented or... Hip joint metal/polymer constrained cemented or uncemented prosthesis. (a) Identification. A hip joint metal/polymer constrained cemented or uncemented prosthesis is a device intended to be implanted to...

  14. 21 CFR 888.3350 - Hip joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint metal/polymer semi-constrained cemented prosthesis. 888.3350 Section 888.3350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... metal/polymer semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/polymer semi...

  15. 21 CFR 888.3340 - Hip joint metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint metal/composite semi-constrained cemented prosthesis. 888.3340 Section 888.3340 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Hip joint metal/composite semi-constrained cemented prosthesis. (a) Identification. A hip joint metal...

  16. 21 CFR 888.3110 - Ankle joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ankle joint metal/polymer semi-constrained cemented prosthesis. 888.3110 Section 888.3110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Ankle joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal...

  17. 21 CFR 888.3160 - Elbow joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Elbow joint metal/polymer semi-constrained cemented prosthesis. 888.3160 Section 888.3160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Elbow joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An elbow joint metal...

  18. 21 CFR 888.3800 - Wrist joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint metal/polymer semi-constrained... Wrist joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A wrist joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a wrist joint...

  19. 21 CFR 888.3110 - Ankle joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ankle joint metal/polymer semi-constrained... Ankle joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an ankle...

  20. 21 CFR 888.3640 - Shoulder joint metal/metal or metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Shoulder joint metal/metal or metal/polymer... § 888.3640 Shoulder joint metal/metal or metal/polymer constrained cemented prosthesis. (a) Identification. A shoulder joint metal/metal or metal/polymer constrained cemented prosthesis is a device...

  1. 21 CFR 888.3120 - Ankle joint metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ankle joint metal/polymer non-constrained cemented... metal/polymer non-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer non... December 26, 1996 for any ankle joint metal/polymer non-constrained cemented prosthesis that was in...

  2. 21 CFR 888.3350 - Hip joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/polymer semi-constrained cemented prosthesis. 888.3350 Section 888.3350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... metal/polymer semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/polymer semi...

  3. 21 CFR 888.3520 - Knee joint femorotibial metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/polymer non... § 888.3520 Knee joint femorotibial metal/polymer non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer non-constrained cemented prosthesis is a device intended to...

  4. 21 CFR 888.3160 - Elbow joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Elbow joint metal/polymer semi-constrained... Elbow joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An elbow joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an elbow...

  5. 21 CFR 888.3310 - Hip joint metal/polymer constrained cemented or uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/polymer constrained cemented or... Hip joint metal/polymer constrained cemented or uncemented prosthesis. (a) Identification. A hip joint metal/polymer constrained cemented or uncemented prosthesis is a device intended to be implanted to...

  6. 21 CFR 888.3170 - Elbow joint radial (hemi-elbow) polymer prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Elbow joint radial (hemi-elbow) polymer prosthesis. 888.3170 Section 888.3170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-elbow) polymer prosthesis. (a) Identification. An elbow joint radial (hemi-elbow) polymer...

  7. 21 CFR 888.3590 - Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint tibial (hemi-knee) metallic resurfacing... Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis is a device intended to be implanted...

  8. 21 CFR 888.3580 - Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellar (hemi-knee) metallic... § 888.3580 Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis is a device made of...

  9. 21 CFR 888.3520 - Knee joint femorotibial metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Knee joint femorotibial metal/polymer non... § 888.3520 Knee joint femorotibial metal/polymer non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer non-constrained cemented prosthesis is a device intended to...

  10. 21 CFR 888.3170 - Elbow joint radial (hemi-elbow) polymer prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Elbow joint radial (hemi-elbow) polymer prosthesis. 888.3170 Section 888.3170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-elbow) polymer prosthesis. (a) Identification. An elbow joint radial (hemi-elbow) polymer...

  11. 21 CFR 888.3800 - Wrist joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint metal/polymer semi-constrained... Wrist joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A wrist joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a wrist joint...

  12. 21 CFR 874.3540 - Prosthesis modification instrument for ossicular replacement surgery.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Prosthesis modification instrument for ossicular replacement surgery. 874.3540 Section 874.3540 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Prosthetic Devices § 874.3540 Prosthesis modification...

  13. 21 CFR 874.3540 - Prosthesis modification instrument for ossicular replacement surgery.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Prosthesis modification instrument for ossicular replacement surgery. 874.3540 Section 874.3540 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Prosthetic Devices § 874.3540 Prosthesis modification...

  14. 21 CFR 874.3540 - Prosthesis modification instrument for ossicular replacement surgery.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Prosthesis modification instrument for ossicular replacement surgery. 874.3540 Section 874.3540 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Prosthetic Devices § 874.3540 Prosthesis modification...

  15. 21 CFR 874.3540 - Prosthesis modification instrument for ossicular replacement surgery.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prosthesis modification instrument for ossicular replacement surgery. 874.3540 Section 874.3540 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Prosthetic Devices § 874.3540 Prosthesis modification...

  16. 21 CFR 874.3540 - Prosthesis modification instrument for ossicular replacement surgery.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Prosthesis modification instrument for ossicular replacement surgery. 874.3540 Section 874.3540 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Prosthetic Devices § 874.3540 Prosthesis modification...

  17. 21 CFR 874.3730 - Laryngeal prosthesis (Taub design).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Laryngeal prosthesis (Taub design). 874.3730 Section 874.3730 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Prosthetic Devices § 874.3730 Laryngeal prosthesis (Taub design). (a) Identification. A...

  18. 21 CFR 888.3640 - Shoulder joint metal/metal or metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Shoulder joint metal/metal or metal/polymer... § 888.3640 Shoulder joint metal/metal or metal/polymer constrained cemented prosthesis. (a) Identification. A shoulder joint metal/metal or metal/polymer constrained cemented prosthesis is a device...

  19. 21 CFR 888.3640 - Shoulder joint metal/metal or metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Shoulder joint metal/metal or metal/polymer... § 888.3640 Shoulder joint metal/metal or metal/polymer constrained cemented prosthesis. (a) Identification. A shoulder joint metal/metal or metal/polymer constrained cemented prosthesis is a device...

  20. 21 CFR 888.3640 - Shoulder joint metal/metal or metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Shoulder joint metal/metal or metal/polymer... § 888.3640 Shoulder joint metal/metal or metal/polymer constrained cemented prosthesis. (a) Identification. A shoulder joint metal/metal or metal/polymer constrained cemented prosthesis is a device...

  1. 21 CFR 888.3640 - Shoulder joint metal/metal or metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Shoulder joint metal/metal or metal/polymer... § 888.3640 Shoulder joint metal/metal or metal/polymer constrained cemented prosthesis. (a) Identification. A shoulder joint metal/metal or metal/polymer constrained cemented prosthesis is a device...

  2. 21 CFR 888.3340 - Hip joint metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/composite semi-constrained... Hip joint metal/composite semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/composite semi-constrained cemented prosthesis is a two-part device intended to be implanted to replace a...

  3. 21 CFR 888.3170 - Elbow joint radial (hemi-elbow) polymer prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Elbow joint radial (hemi-elbow) polymer prosthesis. 888.3170 Section 888.3170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-elbow) polymer prosthesis. (a) Identification. An elbow joint radial (hemi-elbow) polymer...

  4. 21 CFR 888.3170 - Elbow joint radial (hemi-elbow) polymer prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Elbow joint radial (hemi-elbow) polymer prosthesis. 888.3170 Section 888.3170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-elbow) polymer prosthesis. (a) Identification. An elbow joint radial (hemi-elbow) polymer...

  5. 21 CFR 888.3350 - Hip joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint metal/polymer semi-constrained cemented prosthesis. 888.3350 Section 888.3350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... metal/polymer semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/polymer semi...

  6. 21 CFR 888.3310 - Hip joint metal/polymer constrained cemented or uncemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint metal/polymer constrained cemented or... Hip joint metal/polymer constrained cemented or uncemented prosthesis. (a) Identification. A hip joint metal/polymer constrained cemented or uncemented prosthesis is a device intended to be implanted to...

  7. 21 CFR 888.3350 - Hip joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint metal/polymer semi-constrained cemented prosthesis. 888.3350 Section 888.3350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... metal/polymer semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/polymer semi...

  8. 21 CFR 888.3110 - Ankle joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ankle joint metal/polymer semi-constrained... Ankle joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an ankle...

  9. 21 CFR 888.3160 - Elbow joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Elbow joint metal/polymer semi-constrained... Elbow joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An elbow joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an elbow...

  10. 21 CFR 888.3110 - Ankle joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ankle joint metal/polymer semi-constrained... Ankle joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an ankle...

  11. 21 CFR 888.3800 - Wrist joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wrist joint metal/polymer semi-constrained... Wrist joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A wrist joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a wrist joint...

  12. 21 CFR 888.3310 - Hip joint metal/polymer constrained cemented or uncemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint metal/polymer constrained cemented or... Hip joint metal/polymer constrained cemented or uncemented prosthesis. (a) Identification. A hip joint metal/polymer constrained cemented or uncemented prosthesis is a device intended to be implanted to...

  13. 21 CFR 888.3800 - Wrist joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wrist joint metal/polymer semi-constrained... Wrist joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A wrist joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a wrist joint...

  14. 21 CFR 888.3120 - Ankle joint metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ankle joint metal/polymer non-constrained cemented... metal/polymer non-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer non... December 26, 1996 for any ankle joint metal/polymer non-constrained cemented prosthesis that was in...

  15. 21 CFR 888.3160 - Elbow joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Elbow joint metal/polymer semi-constrained... Elbow joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An elbow joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an elbow...

  16. 21 CFR 888.3160 - Elbow joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Elbow joint metal/polymer semi-constrained... Elbow joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An elbow joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an elbow...

  17. 21 CFR 888.3520 - Knee joint femorotibial metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Knee joint femorotibial metal/polymer non... § 888.3520 Knee joint femorotibial metal/polymer non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer non-constrained cemented prosthesis is a device intended to...

  18. 21 CFR 888.3310 - Hip joint metal/polymer constrained cemented or uncemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint metal/polymer constrained cemented or... Hip joint metal/polymer constrained cemented or uncemented prosthesis. (a) Identification. A hip joint metal/polymer constrained cemented or uncemented prosthesis is a device intended to be implanted to...

  19. 21 CFR 888.3520 - Knee joint femorotibial metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Knee joint femorotibial metal/polymer non... § 888.3520 Knee joint femorotibial metal/polymer non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer non-constrained cemented prosthesis is a device intended to...

  20. 21 CFR 888.3110 - Ankle joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ankle joint metal/polymer semi-constrained... Ankle joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an ankle...

  1. 21 CFR 888.3350 - Hip joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint metal/polymer semi-constrained cemented prosthesis. 888.3350 Section 888.3350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... metal/polymer semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/polymer semi...

  2. 21 CFR 888.3170 - Elbow joint radial (hemi-elbow) polymer prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Elbow joint radial (hemi-elbow) polymer prosthesis. 888.3170 Section 888.3170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-elbow) polymer prosthesis. (a) Identification. An elbow joint radial (hemi-elbow) polymer...

  3. 21 CFR 888.3520 - Knee joint femorotibial metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Knee joint femorotibial metal/polymer non... § 888.3520 Knee joint femorotibial metal/polymer non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer non-constrained cemented prosthesis is a device intended to...

  4. 21 CFR 888.3800 - Wrist joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wrist joint metal/polymer semi-constrained... Wrist joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A wrist joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a wrist joint...

  5. 21 CFR 888.3120 - Ankle joint metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... substantially equivalent to an ankle joint metal/polymer non-constrained cemented prosthesis that was in... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ankle joint metal/polymer non-constrained cemented... metal/polymer non-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer non...

  6. 21 CFR 888.3120 - Ankle joint metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... substantially equivalent to an ankle joint metal/polymer non-constrained cemented prosthesis that was in... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ankle joint metal/polymer non-constrained cemented... metal/polymer non-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer non...

  7. 21 CFR 888.3120 - Ankle joint metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... substantially equivalent to an ankle joint metal/polymer non-constrained cemented prosthesis that was in... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ankle joint metal/polymer non-constrained cemented... metal/polymer non-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer non...

  8. Femoral Prosthesis Infection by Rhodotorula mucilaginosa▿

    PubMed Central

    Savini, Vincenzo; Sozio, Federica; Catavitello, Chiara; Talia, Marzia; Manna, Assunta; Febbo, Fabio; Balbinot, Andrea; Di Bonaventura, Giovanni; Piccolomini, Raffaele; Parruti, Giustino; D'Antonio, Domenico

    2008-01-01

    This case report is a case history of a femoral prosthesis infection caused by Rhodotorula mucilaginosa in a human immunodeficiency virus patient. Though the pathogenicity of this organism for bone tissue has been previously reported, this is the first reported case of an orthopedic prosthesis infection by this species of the genus Rhodotorula. PMID:18753353

  9. Design and Control of a Pneumatically Actuated Transtibial Prosthesis.

    PubMed

    Zheng, Hao; Shen, Xiangrong

    2015-04-01

    This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided by this highly competitive actuator. In this paper, the design details of the prosthesis are described, including the determination of performance specifications, the layout of the actuation mechanism, and the calculation of the torque capacity. Through the authors' design calculation, the prosthesis is able to provide sufficient range of motion and torque capacity to support the locomotion of a 75 kg individual. The controller design is also described, including the underlying biomechanical analysis and the formulation of the finite-state impedance controller. Finally, the human subject testing results are presented, with the data indicating that the prosthesis is able to generate a natural walking gait and sufficient power output for its amputee user.

  10. Teflon-wire piston or stainless-steel bucket stapes prosthesis: does it make a difference?

    PubMed

    Farrior, J B; Temple, A E

    1999-04-01

    The goal of this study was to determine whether postoperative (implantation of a stapes prosthesis) hearing gain and the amount of air-bone gap overclosure are more improved with the Teflon-wire piston or with the stainless-steel bucket prosthesis. We retrospectively reviewed the outcomes of 82 surgeries that had been performed by the primary author; 41 of these patients had received a Fisch Teflon-wire piston, and 41 had received a Bailey-modified Robinson stainless-steel bucket prosthesis. The mean hearing gain for the patients who received the Teflon-wire piston was 23.3 dB after primary stapes surgery and 20.5 dB after revision surgery. Patients who received the stainless-steel bucket prosthesis experienced a mean hearing gain of 20.7 and 20.3 dB, respectively. Following primary stapes surgery, the air-bone gap overclosure was 4.4 dB with the Teflon-wire piston and 5.2 dB with the stainless-steel bucket prosthesis. There was no statistically significant difference in either hearing gain or air-bone gap overclosure between the two prostheses.

  11. Design and Control of a Pneumatically Actuated Transtibial Prosthesis

    PubMed Central

    Zheng, Hao; Shen, Xiangrong

    2015-01-01

    This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided by this highly competitive actuator. In this paper, the design details of the prosthesis are described, including the determination of performance specifications, the layout of the actuation mechanism, and the calculation of the torque capacity. Through the authors’ design calculation, the prosthesis is able to provide sufficient range of motion and torque capacity to support the locomotion of a 75 kg individual. The controller design is also described, including the underlying biomechanical analysis and the formulation of the finite-state impedance controller. Finally, the human subject testing results are presented, with the data indicating that the prosthesis is able to generate a natural walking gait and sufficient power output for its amputee user. PMID:26146497

  12. A hollow definitive obturator fabrication technique for management of partial maxillectomy.

    PubMed

    Patil, Pravinkumar Gajanan; Patil, Smita Pravinkumar

    2012-11-01

    Maxillary obturator prosthesis is the most frequent treatment option for management of partial or total maxillectomy. Heavy weight of the obturators is often a dislocating factor. Hollowing the prosthesis to reduce its weight is the well established fact. The alternate technique to hollow-out the prosthesis has been described in this article which is a variation of previously described processing techniques. A pre-shaped wax-bolus was incorporated inside the flasks during packing of the heat-polymerized acrylic resin to automatically create the hollow space. The processing technique described is a single step flasking procedure to construct a closed-hollow-obturator prosthesis as a single unit. To best understand the technique, this article describes management of a patient who had undergone partial maxillectomy secondary to squamous cell carcinoma rehabilitated with a hollow-obturator prosthesis.

  13. A hollow definitive obturator fabrication technique for management of partial maxillectomy

    PubMed Central

    Patil, Smita Pravinkumar

    2012-01-01

    Maxillary obturator prosthesis is the most frequent treatment option for management of partial or total maxillectomy. Heavy weight of the obturators is often a dislocating factor. Hollowing the prosthesis to reduce its weight is the well established fact. The alternate technique to hollow-out the prosthesis has been described in this article which is a variation of previously described processing techniques. A pre-shaped wax-bolus was incorporated inside the flasks during packing of the heat-polymerized acrylic resin to automatically create the hollow space. The processing technique described is a single step flasking procedure to construct a closed-hollow-obturator prosthesis as a single unit. To best understand the technique, this article describes management of a patient who had undergone partial maxillectomy secondary to squamous cell carcinoma rehabilitated with a hollow-obturator prosthesis. PMID:23236579

  14. A new biomechanical hand prosthesis controlled by surface electromyographic signals.

    PubMed

    Andrade, Nei A; Borges, Geovany A; de O Nascimento, Francisco A; Romariz, Alexandre R S; da Rocha, Adson F

    2007-01-01

    This paper describes the development of a low-cost hand prosthesis for use in patients with an amputated hand due to congenital problems or to trauma wound, who possess a part or the forearm endowed with muscular activity. The paper covers the constructive aspects of both mechanical and electronic designs. The prototype is controlled by electromyographic signals measured at the remaining part of the injured limb of the patient. The EMG signals are measured at the surface of the skin, at a point that is close to a working muscle of the amputated arm. The prosthesis allows the patient to hold objects by means of a three finger clamp. The prosthesis presented an excellent performance in preliminary tests with an amputated patient. These tests showed that the prosthesis had a very good performance regarding force and speed.

  15. Vent-induced prosthetic leaflet thrombosis treated by open-heart valve-in-valve implantation.

    PubMed

    Stamm, Christof; Pasic, Miralem; Buz, Semih; Hetzer, Roland

    2015-09-01

    A patient required emergency mitral valve replacement and extracorporeal membrane oxygenation (ECMO) support for acute biventricular failure. The left ventricular (LV) vent inserted via the left upper pulmonary vein induced thrombotic immobilization of a prosthetic valve leaflet, with significant intra-prosthesis regurgitation after ECMO explantation. Therefore, the left atrium was opened on the beating heart during conventional extracorporeal circulation, all prosthesis leaflets were excised and a 29-mm expandable Edwards Sapien prosthesis was inserted within the scaffold of the original prosthesis under direct vision. This case illustrates the benefits and potential problems of LV venting on ECMO support, and a rapid and safe way of replacing the prosthesis leaflets in a critical situation. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  16. Rehabilitation with dental prosthesis can increase cerebral regional blood volume.

    PubMed

    Miyamoto, Ikuya; Yoshida, Kazuya; Tsuboi, Yoichi; Iizuka, Tadahiko

    2005-12-01

    Treatment with denture for edentulous people is highly important for maintaining quality of life. However, its effect on the brain is unknown. In this experimental study, we hypothesized that dental prosthesis can recover not only the physical condition of mastication system but also the regional brain activity. We evaluated functional brain imaging of edentulous subjects fixed by dental implant prosthesis with clenching tasks by multi-channel near-infrared optical topography. Results revealed a significantly (P<0.001; paired t-test) increased cerebral regional blood volume during maximum voluntary clenching task by implant-retained prosthesis. There were no statistically significant differences between patients with and without prosthesis in the latency to the maximum regional blood volume after the task. Conclusively, clenching can be effective for increasing cerebral blood volume; accordingly maintenance of normal chewing might prevent the brain from degenerating.

  17. Candida albicans, Staphylococcus aureus and Streptococcus mutans colonization in patients wearing dental prosthesis.

    PubMed

    Baena-Monroy, Tania; Moreno-Maldonado, Víctor; Franco-Martínez, Fernando; Aldape-Barrios, Beatriz; Quindós, Guillermo; Sánchez-Vargas, Luis Octavio

    2005-04-01

    Denture stomatitis is associated to Candida albicans, different bacteria and other co-factors such as an acid pH, a carbohydrate ingestion increase, different systemic illnesses and pharmacological treatments. The aim of this study was to determine Candida albicans, Staphylococcus aureus and Streptococcus mutans prevalence in the mucous membrane and prosthesis of patients with and without atrophic denture stomatitis and its relationship with other potential clinical co-factors. Saliva was collected from 105 patients (62 female and 43 male) wearing dental prosthesis in order to measure their pH. Oral samples of the mucous membrane and the internal surface of dental prosthesis were taken with sterile cotton to proceed with the microbiological study. The identification of the isolated microorganisms was performed using conventional microbiological methods. Diabetes and Hypertension were the most frequent systemic illnesses. High carbohydrate ingestion was observed in numerous patients. Atrophic denture stomatitis was reported in 50 patients and the pH average in saliva was of 5.2. The presence of C albicans, S. aureus and S. mutans in the mucous membrane and prosthesis was of 51.4%, 52.4% and 67.6%, respectively. C. albicans was isolated in 66.7% from the prosthesis, whereas S. aureus and S. mutans were isolated in 49.5% of those same prosthesis. C. albicans was isolated in 86% of the patients with atrophic denture stomatitis and S. aureus was isolated in a similar percentage (84% of patients). The isolation of S. mutans was less frequent, and it was observed in 16% of the oral samples of these patients. C. albicans, S. aureus and S. mutans frequently colonize the oral mucous of patients wearing dental prosthesis. This illness-bearing condition is more frequent in patients with denture stomatitis, even though dental prosthesis colonization is lower than in the oral mucous.

  18. Biocompatible membrane of PDMS for the new chamber prosthesis stapes.

    PubMed

    Banasik, Katarzyna; Kwacz, Monika

    2016-06-30

    Stapes protheses are designed for patients with otosclerosis resulting immobilization or significant reduction of the stapes mobility. All currently used prostheses are called - piston prosthesis. However, its use to stimulate the cochlea is still imperfect. New chamber stapes prosthesis allows the perilymph excitation more effective than the piston prothesis. Moreover, the chamber prosthesis eliminates the common causes of piston-stapedotomy failures. The most important element of the new prosthesis is a flexible membrane. The membrane stiffness should be close to the stiffness of normal annular ligament. This work presents the process of selection of the membrane's thickness and its manufacturing technology. Method A 3D model of the chamber stapes prosthesis was build using Autodesk Inventor 2015. The model was imported to Abacus 6.13 computing environment. During numerical simulations, displacements corresponding to applied loads were calculated and the membrane thickness was adjusted so that its stiffness was the same as the ligament stiffness (~ 120 N/m). The compliance ratios calculated from the load-displacement curves for the membrane and the annular ligament were verified using linear regression analysis. After determining the thickness, the manufacturing technology of the membrane was developed. Results The best similarity between the membrane's and annular ligament's stiffness was achieved for PDMS membrane with the 0,15- mm thickness (similarity ratio R2=0,997752). In this work, the technological parameters of spin-coating process for membrane manufacture are also presented. Summary The proper functioning of the chamber stapes prosthesis requires the PDMS membrane with a thickness of 0,15 mm. The 0,15-mm membrane has the tiffness close to the stiffness of the normal annular ligament. Therefore, the chamber stapes prosthesis provides the perilymph stimulation at the level comparable to the healthy ear. New prosthesis is currently under pre-clinical investigation to optimize the shape of the inner chamber's surface.

  19. Kinematic Analysis of a Posterior-stabilized Knee Prosthesis

    PubMed Central

    Zhao, Zhi-Xin; Wen, Liang; Qu, Tie-Bing; Hou, Li-Li; Xiang, Dong; Bin, Jia

    2015-01-01

    Background: The goal of total knee arthroplasty (TKA) is to restore knee kinematics. Knee prosthesis design plays a very important role in successful restoration. Here, kinematics models of normal and prosthetic knees were created and validated using previously published data. Methods: Computed tomography and magnetic resonance imaging scans of a healthy, anticorrosive female cadaver were used to establish a model of the entire lower limbs, including the femur, tibia, patella, fibula, distal femur cartilage, and medial and lateral menisci, as well as the anterior cruciate, posterior cruciate, medial collateral, and lateral collateral ligaments. The data from the three-dimensional models of the normal knee joint and a posterior-stabilized (PS) knee prosthesis were imported into finite element analysis software to create the final kinematic model of the TKA prosthesis, which was then validated by comparison with a previous study. The displacement of the medial/lateral femur and the internal rotation angle of the tibia were analyzed during 0–135° flexion. Results: Both the output data trends and the measured values derived from the normal knee's kinematics model were very close to the results reported in a previous in vivo study, suggesting that this model can be used for further analyses. The PS knee prosthesis underwent an abnormal forward displacement compared with the normal knee and has insufficient, or insufficiently aggressive, “rollback” compared with the lateral femur of the normal knee. In addition, a certain degree of reverse rotation occurs during flexion of the PS knee prosthesis. Conclusions: There were still several differences between the kinematics of the PS knee prosthesis and a normal knee, suggesting room for improving the design of the PS knee prosthesis. The abnormal kinematics during early flexion shows that the design of the articular surface played a vital role in improving the kinematics of the PS knee prosthesis. PMID:25591565

  20. [Rehabilitation by hollow obturator prosthesis immediately after total maxillectomy for malignant tumor].

    PubMed

    Li, Xiao-ye; Yan, Ai-hui; Hao, Shuai; Li, Wei; Jiang, Xue-jun; Lu, Li; Qin, Xing-jun; Yan, Hai-xin

    2011-05-01

    The feasibility and clinical effects of hollow obturator prosthesis for the repair of maxillofacial defect immediately after maxillectomy for cancer were assessed. Thirteen patients with T3-4aN0M0 maxillary neoplasm were treated by the prostheses immediately after maxillectomy. According to the 3D-CT reconstruction of nasal sinus, the 3D stereoscopic prototype was constructed before the surgery. Simulating surgery with Surgicare 5.0 software and then the prosthesis 3D stereoscopic model was shaped. The prosthesis was made quickly and precisely with methacrylate resins according to the model and the print mold before surgery, with supplementary tooth at the bottom of prosthesis. In the surgery, the prosthesis was installed instantly after maxillectomy. The patients were followed up at 1, 3 and 6 month after the surgery, respectively. The facial features and the pronunciation clarity were examined and the questionnaires were carried out in the patients, with comparation by paired t-test. The hollow obturator prosthesis would be replaced by permanent prosthesis made of methacrylate resins at 6 month after the surgery. The hollow obturator prostheses were installed accurately and maxillofacial defects were repaired immediately after maxillectomy in the 13 patients. Postoperative follow-up showed there were significant differences in eyeball sagging (t = 4.67, P < 0.05), mid-facial region collapse (t = 5.67, P < 0.05), and pronunciation clarity (t = 16.38, P < 0.05) between patients with and without prostheses. Questionnaires showed that all the patients were satisfied with the retention of prostheses, the improvement of appearance, the improvement of the symptom of water choking and speech definition. Six months after the surgery, the hollow obturator prostheses were replaced smoothly by permanent prostheses in 11 of the 13 patients. The precise and instant repair of maxillofacial defect by prosthesis after maxillectomy can improve survival quality of patient.

  1. A second prosthesis as a procedural rescue option in trans-apical aortic valve implantation.

    PubMed

    Kempfert, Jörg; Rastan, Ardawan J; Schuler, Gerhard; Linke, Axel; Holzhey, David; van Linden, Arnaud; Mohr, Friedrich-W; Walther, Thomas

    2011-07-01

    Trans-apical aortic valve implantation (TA-AVI) using the Edwards SAPIEN™ prosthesis has evolved to a routine procedure for selected high-risk elderly patients. In rare cases, misplacement of the SAPIEN™ valve (too low a position), dysfunction of the leaflets or perforation of the interventricular septum (ventricular septal defect, VSD) occurs and requires immediate implantation of a second prosthesis within the first one. Results of this 'bailout' maneuver have not been reported yet. Of 305 TA-AVI procedures, 15 patients required a second prosthesis due to dysfunctional leaflets (n = 6), low position (n = 7), or VSD (n = 2). Mean age was 82.5 ± 1.3 years, mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 45.5 ± 5.4, and Society of Thoracic Surgeons (STS) Score was 13.5 ± 1.5. All second SAPIEN™ valves could be implanted successfully within the first one. The second prosthesis solved leaflet dysfunction, sealed the VSD (lower position of the second prosthesis), or corrected the initial misplacement (higher position of the second prosthesis) in all patients. Within 30 days, four patients died (low cardiac output n = 3, all with preoperative ejection fraction (EF) <35%; intestinal ischemia n = 1). Intra-operative echocardiogram and angiogram revealed mild paravalvular leak in three and none/trace in 12 patients. Transvalvular gradients were low despite the implantation of the second valve (P(max)/mean 13.7 ± 4.3/6.4 ± 2.0). Placement of a second SAPIEN™ valve is a valuable 'bailout' technique in case of VSD, dysfunctional leaflets, or too low placement of the first prosthesis. The technique leads to an excellent functional result with low transvalvular gradients. The simple, straight, tubular stent design of the SAPIEN™ prosthesis may be the ideal design for such valve-in-valve procedures. Copyright © 2011 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  2. [Treatment of periprosthetic femoral fractures after total hip arthroplasty with specially constructed retrograde hollow nails].

    PubMed

    Szalay, G; Meyer, C; Mika, J; Schnettler, R; Thormann, U

    2014-12-01

    Treatment of periprosthetic fractures by implantation of a specially constructed, retrograde hollow nail which fits over the tip of the prosthesis and becomes locked on it. Periprosthetic femoral fractures with firmly anchored prosthesis shaft after total hip arthroplasty of types B1 and C according to the Vancouver classification. Loosened prosthesis (type B2/B3) and trochanteric fractures (type A). Broken or damaged prosthesis, florid inflammation and soft tissue injuries in the operation field, contracted knee joint, advanced deformation in the knee joint and distal femur, enclosed prosthesis and general contraindications. In a supine position the periprosthetic fracture is exposed via a lateral access. For cemented prostheses the cement is removed around the tip of the prosthesis (at least 2-3 cm) and medullary cavity. Arthrotomy with flexion of the knee joint and marking of the nail entry point. Drill the medullary cavity, retrograde introduction of the nail, visually fit the nail over the tip of the prosthesis and lock the nail with the prosthesis. If necessary use additional spongiosaplasty or also placement of additional cerclages depending on fracture type and size of the defect zone. Lock the nail distally. Use intraoperative radiological imaging to control correct positioning and length of the nail. Close the wound layer by layer with placement of suction drainage devices and dressing. Partial loading for 6 weeks with a subsequent pain-adapted loading gradient until full loading is possible. If selective partial loading is not possible, a decision must be made in individual cases as to whether the intraoperative findings allow immediate full loading. From 2004 to 2011 a total of 25 periprosthetic femoral fractures in 25 patients were treated in 2 locations using specially constructed slotted hollow nails. Within the framework of a retrospective study 20 of these patients (16 female and 4 male; average age 77.2 [72-84] years) were clinically and radiologically re-examined on average 19.3 (7-31) months postoperatively. No postoperative bleeding, wound healing disorders and infections. In all patients there was a loading stable consolidation of the fracture in the correct femoral axis, length and rotation with no evidence for radiological signs of loosening of the prosthesis or dislocation of the nails. In one case there was loosening of the prosthesis which had obviously occurred during the operative procedure. After consolidation of the fracture it was necessary to exchange the prosthesis for a long shafted prosthesis. A comparable situation to the preoperative degree of mobility was found in 12 out of the 20 patients, a moderate deterioration in 5 patients, a substantial residual impairment in 2 patients and an improvement of the situation in 1 patient.

  3. Calfplasty.

    PubMed

    Felício, Y

    2000-01-01

    The author describes a method of calf augmentation by a silicone prosthesis implant for correction of asymmetrical legs or aesthetic problems. Preference is given to the placement of soft silicone implants (Glitzentein implants); they are more natural looking than hard implants. The implants are placed over both heads of the gastrocnemius muscle or beneath the fascia cruris superficialis. Operations were performed from November 1985 to August 1999. One hundred patients were studied: 95 female and 5 male. Two hundred calf implants were performed: 188 soft implants (Glitzenstein), 6 hard implants (Aiache), and 6 together on the same leg (Glitzenstein and Aiache implants). No infection problems, prosthesis rupture, or hematomas occurred. There were four seromas, but they disappeared in 15 days. Four prostheses were removed in two patients who did not like the final result. One prosthesis changed place, to the upper part of the calf. The operation is performed under sedative and local anesthesia, with an incision of approximately 4 to 5 cm in the popliteal pleat, at the same height as the fascia cruris. To date, no functional problem or muscular dysfunction has been provoked by silicone prosthesis implants. The patient walks 8 h after the surgery. We selected 500 patients who received implants in the legs with calf prostheses, fat implants, and prosthesis and fat implant together, during 14 years of follow-up, but the focus of this paper is a calf implant with prosthesis in 100 patients with 200 calf prosthesis implants.

  4. Function of obturator prosthesis after maxillectomy and prosthetic obturator rehabilitation.

    PubMed

    Chen, Cheng; Ren, Wenhao; Gao, Ling; Cheng, Zheng; Zhang, Linmei; Li, Shaoming; Zhi, Pro Ke-qian

    2016-01-01

    Maxillary defects are usually rehabilitated by a prosthetic obturator. This study aimed to evaluate the functioning of obturators prosthesis in patients with unilateral defects after maxillectomy. Of 49 patients, 28 underwent to maxillectomy as a result of tumor ablative surgery, and acquired unilateral maxillary defects. Evaluation of the function was performed by applying the Obturator Functional Scale (OFS). From a total of 49 patients, 28 were treated as follows: 9 with a conventional retained obturator prosthesis (COP), 11 (39%) with an enhanced retentive obturator prosthesis with stud attachment (POP) and 8 (28%) with an enhanced retentive obturator prosthesis with magnetic attachment (POM). The mean OFS score was 80. Scores on functions of speech, swallowing and chewing reached statistical significances (p<0.05) among these three subgroups. Comparing COP and MOP groups, the scores of OFS in the domains of "Speech-ability to speak in public" and "Swallowing-leakage with liquids" were significantly higher in AOP group. Comparing COP group, the scores of OFS in "Swallowing-leakage with solid" and "Chewing/eating" domains were increased significantly (p<0.05) both in MOP and AOP groups. Obturator prosthesis improves oral function of patients after maxillary defects; the retention of the obturator prosthesis enhanced by the addition of attachments showed more benefits in oral function. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  5. Percutaneous coronary angioplasty of a left anterior descending artery implanted on a Dacron coronary prosthesis on an aortic conduit.

    PubMed

    Drobinski, G; Thomas, D; Funck, F; Metzger, J P; Canny, M; Grosgogeat, Y

    1986-08-01

    Certain surgical techniques may make it difficult to catheterize the coronary ostia and perform percutaneous coronary angioplasty. We report the case of a 48 year old patient who developed unstable angina four years after a Bentall's procedure with reimplantation of the coronary arteries on a Dacron coronary prosthesis. The anginal pain was related to very severe stenosis of the proximal segment of the left anterior descending artery. The difficulties encountered during the dilatation procedure were due to: (a) the ectopic position of the ostium of the prosthesis on the anterior aortic wall; (b) the forces exerted on the aortic prosthesis wall and on the valvular prosthesis during positioning of the guiding catheter which were poorly tolerated and induced a vagal reaction; (c) the direction taken by the distal tip of the guiding catheter, perpendicular to the wall of the aortic prosthesis; (d) the sinuosity of the arterial trajectory: the left coronary segment of the coronary prosthesis was directed towards the left circumflex artery rather than towards the left anterior descending artery. Coronary angioplasty succeeded after relatively complex technical procedures: special guiding catheter, unusual intra-aortic manoeuvres for positioning the guiding catheter, dilatation catheter change on a 3-metre long guide wire in order to cross the stenotic segment; this was performed with a super low-profiled dilatation catheter. There were no complications and anginal pain disappeared.

  6. Bionic ankle–foot prosthesis normalizes walking gait for persons with leg amputation

    PubMed Central

    Herr, Hugh M.; Grabowski, Alena M.

    2012-01-01

    Over time, leg prostheses have improved in design, but have been incapable of actively adapting to different walking velocities in a manner comparable to a biological limb. People with a leg amputation using such commercially available passive-elastic prostheses require significantly more metabolic energy to walk at the same velocities, prefer to walk slower and have abnormal biomechanics compared with non-amputees. A bionic prosthesis has been developed that emulates the function of a biological ankle during level-ground walking, specifically providing the net positive work required for a range of walking velocities. We compared metabolic energy costs, preferred velocities and biomechanical patterns of seven people with a unilateral transtibial amputation using the bionic prosthesis and using their own passive-elastic prosthesis to those of seven non-amputees during level-ground walking. Compared with using a passive-elastic prosthesis, using the bionic prosthesis decreased metabolic cost by 8 per cent, increased trailing prosthetic leg mechanical work by 57 per cent and decreased the leading biological leg mechanical work by 10 per cent, on average, across walking velocities of 0.75–1.75 m s−1 and increased preferred walking velocity by 23 per cent. Using the bionic prosthesis resulted in metabolic energy costs, preferred walking velocities and biomechanical patterns that were not significantly different from people without an amputation. PMID:21752817

  7. [Pelvic reconstructions after bone tumor resection].

    PubMed

    Anract, Philippe; Biau, David; Babinet, Antoine; Tomeno, Bernard

    2014-02-01

    The three more frequent primitive malignant bone tumour which concerned the iliac bone are chondrosarcoma, following Ewing sarcoma and osteosarcoma. Wide resection remains the most important part of the treatment associated with chemotherapy for osteosarcoma and the Ewing sarcoma. Iliac wing resections and obdurate ring don't required reconstruction. However, acetabular resections and iliac wing resection with disruption of the pelvic ring required reconstruction to provide acceptable functional result. Acetabular reconstruction remains high technical demanding challenge. After isolated acetabular resection or associated to obdurate ring, our usual method of reconstruction is homolateral proximal femoral autograft and total hip prosthesis but it is possible to also used : saddle prosthesis, Mac Minn prosthesis with auto or allograft, modular prosthesis or custom made prosthesis, massive allograft with or without prosthesis and femoro-ilac arthrodesis. After resection of the iliac wing plus acetabulum, reconstruction can be performed by femoro-obturatrice and femora-sacral arthrodesis, homolateral proximal femoral autograft and prosthesis, femoral medialisation, massive allograft and massive allograft. Carcinological results are lesser than resection for distal limb tumor, local recurrence rate range 17 to 45%. Functional results after Iliac wing and obdurate ring are good. However, acetabular reconstruction provide uncertain functional results. The lesser results arrive after hemipelvic or acetabular and iliac wing resection-reconstruction, especially when gluteus muscles were also resected. The most favourable results arrive after isolated acetabular or acetabular plus obturateur ring resection-reconstruction.

  8. Dose calculations using artificial neural networks: A feasibility study for photon beams

    NASA Astrophysics Data System (ADS)

    Vasseur, Aurélien; Makovicka, Libor; Martin, Éric; Sauget, Marc; Contassot-Vivier, Sylvain; Bahi, Jacques

    2008-04-01

    Direct dose calculations are a crucial requirement for Treatment Planning Systems. Some methods, such as Monte Carlo, explicitly model particle transport, others depend upon tabulated data or analytic formulae. However, their computation time is too lengthy for clinical use, or accuracy is insufficient, especially for recent techniques such as Intensity-Modulated Radiotherapy. Based on artificial neural networks (ANNs), a new solution is proposed and this work extends the properties of such an algorithm and is called NeuRad. Prior to any calculations, a first phase known as the learning process is necessary. Monte Carlo dose distributions in homogeneous media are used, and the ANN is then acquired. According to the training base, it can be used as a dose engine for either heterogeneous media or for an unknown material. In this report, two networks were created in order to compute dose distribution within a homogeneous phantom made of an unknown material and within an inhomogeneous phantom made of water and TA6V4 (titanium alloy corresponding to hip prosthesis). All NeuRad results were compared to Monte Carlo distributions. The latter required about 7 h on a dedicated cluster (10 nodes). NeuRad learning requires between 8 and 18 h (depending upon the size of the training base) on a single low-end computer. However, the results of dose computation with the ANN are available in less than 2 s, again using a low-end computer, for a 150×1×150 voxels phantom. In the case of homogeneous medium, the mean deviation in the high dose region was less than 1.7%. With a TA6V4 hip prosthesis bathed in water, the mean deviation in the high dose region was less than 4.1%. Further improvements in NeuRad will have to include full 3D calculations, inhomogeneity management and input definitions.

  9. Chewing efficiency, bite force and oral health-related quality of life with narrow diameter implants - a prospective clinical study: results after one year.

    PubMed

    Enkling, Norbert; Saftig, Marcus; Worni, Andreas; Mericske-Stern, Regina; Schimmel, Martin

    2017-04-01

    This prospective study aimed to investigate the evolution of chewing efficiency, maximum voluntary bite force (MBF) and oral health-related quality of life (OHRQoL) in edentulous patients treated with narrow diameter implants (NDIs) over the course of 1 year. Four NDIs (MDI ® , 3M ESPE, diameter 1.8 mm) were placed interforaminally in 20 edentulous patients. They were immediately loaded by converting the existing prosthesis into an implant overdenture. Participants were examined six times pre- and postoperatively [baseline (BL) to week 52 (w52)]. Chewing efficiency was evaluated with a colour-mixing ability test by evaluation of the standard deviation of hue (VOH, ViewGum©). MBF was measured using a digital force gauge. OHRQoL was determined with the Oral Health Impact Profile (OHIPG49). Nonparametric Brunner-Langer models were applied for statistical testing. The study failed to demonstrate an effect on chewing efficiency. MBF increased continuously during the observation period (medians: MBF[N]@BL = 46.6 [iqr 50.1]; MBF[N]@w52 = 103.9 [iqr 76.0]; P = 0.002). OHRQoL increased steeply after implant loading and continued improving (medians: BL ∑OHIPG49 = 31 [iqr 40.0]; w4 ∑OHIPG49 = 11.5 [iqr 19.5]; w52 ∑OHIPG49 = 6 [iqr 13.0], P < 0.001). The stabilisation of a lower complete prosthesis with four NDIs is a feasible minimally invasive and economical approach to improve oral function and OHRQoL, especially in elderly patients with limited bone support. Functional benefits might be more evident if patients receive chewing instructions. Larger studies need to confirm a positive effect on chewing efficiency and develop long-term maintenance solutions if patients become frail because no easy downgrading approaches of one-piece titanium implants exist. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. 21 CFR 888.3358 - Hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/polymer/metal semi-constrained... Devices § 888.3358 Hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis. (a) Identification. A hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis is a device...

  11. 21 CFR 888.3390 - Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metal/polymer... § 888.3390 Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis is a two-part...

  12. Variable Cadence Walking and Ground Adaptive Standing with a Powered Ankle Prosthesis

    PubMed Central

    Shultz, Amanda H.; Lawson, Brian E.; Goldfarb, Michael

    2015-01-01

    Abstract This paper describes a control approach that provides walking and standing functionality for a powered ankle prosthesis, and demonstrates the efficacy of the approach in experiments in which a unilateral transtibial amputee subject walks with the prosthesis at variable cadences, and stands on various slopes. Both controllers incorporate a finite-state structure that emulates healthy ankle joint behavior via a series of piecewise passive impedance functions. The walking controller incorporates an algorithm to modify impedance parameters based on estimated cadence, while the standing controller incorporates an algorithm to modulate the ankle equilibrium angle in order to adapt to the ground slope and user posture, and the supervisory controller selects between the walking and standing controllers. The system is shown to reproduce several essential biomechanical features of the healthy joint during walking, particularly relative to a passive prosthesis, and is shown to adapt to variable cadences. The system is also shown to adapt to slopes over a range of ± 15 deg and to provide support to the user in a manner that is biomimetic, as validated by quasi-static stiffness measurements recorded by the prosthesis. Data from standing trials indicate that the user places more weight on the powered prosthesis than on his passive prosthesis when standing on sloped surfaces, particularly at angles of 10 deg or greater. The authors also demonstrated that the prosthesis typically began providing support within 1 s of initial contact with the ground. Further, the supervisory controller was shown to be effective in switching between walking and standing, as well as in determining ground slope just prior to the transition from the standing controller to the walking controller, where the estimated ground slope was within 1.25 deg of the actual ground slope for all trials. PMID:25955789

  13. Clinical Outcome of Medial Pivot Compared With Press-Fit Condylar Sigma Cruciate-Retaining Mobile-Bearing Total Knee Arthroplasty.

    PubMed

    Kim, Young-Hoo; Park, Jang-Won; Kim, Jun-Shik

    2017-10-01

    The purpose of this study was to compare the long-term clinical results, radiographic results, range of knee motion, patient satisfaction, and the survival rate of Medial-Pivot posterior cruciate-substituting, knee prosthesis and a press-fit condylar (PFC) Sigma cruciate-retaining mobile-bearing knee prosthesis in the same patients. One hundred eighty-two patients received Medial-Pivot knee prosthesis in one knee and a PFC Sigma knee prosthesis in the contralateral knee. The minimum duration of follow-up was 11 years (range, 11-12.6 years). The knees with a Medial-Pivot knee prosthesis had significantly worse results than those with a PFC Sigma knee prosthesis at the final follow-up with regard to the mean postoperative Knee Society knee scores (90 compared with 95 points), Western Ontario and McMaster Universities Osteoarthritis Index score (25 compared with 18 points), and range of knee motion (117° compared with 128°). Patients were more satisfied with PFC Sigma knee prosthesis (93%) than with Medial-Pivot knee prosthesis (75%). Complication rates were significantly higher in the Medial-Pivot knee group (26%) than those in the PFC Sigma knee group (6.5%). Radiographic results and survival rates (99% compared with 99.5%) were similar between the 2 groups. Although the long-term fixation and survival rate of both Medial-Pivot and PFC Sigma prostheses were similar, we observed a worse knee score, worse range of knee motion, and patient satisfaction was less in the Medial-Pivot knee group than in the PFC Sigma knee group. Furthermore, complication rate was also higher in the Medial-Pivot knee group than the other group. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. [The length of the piston in otosclerosis surgery].

    PubMed

    Portmann, D; Alcantara, M; Vianna, M

    2007-01-01

    The measurement of the piston is always described as a significant stage of the surgery but its length is never clearly defined. The goal of this work is to determine the length of the prosthesis. From May 2003 to May 2005, 128 patients with otosclerosis, diagnosed on the basis of their clinical history and their audiogram, were included in this prospective study. Some of them were revision surgeries. The prosthesis generally used was the Portmann piston clip (Medtronic Xomed Inc Portmann Piston Clip Stainless Steel/Fluoroplastic). In stapedectomies, a Teflon piston of 0.6 mm of diameter was used (Pouret Company Fluoroplastic Stapes Prosthesis). These prostheses must be trimmed before their installation. The measurement technique is described. The length of the prosthesis was increased by 0.5 mm to include the thickness of the footplate. The Portmann piston clip was used 116 times (100 initial surgeries and 16 revisions surgeries) and the Teflon prosthesis of 0.6 mm of diameter only 13 times (6 primary stapedectomies and 7 revisions stapedectomies). The length of the prosthesis was between 3,5 mm and 5 mm. In the majority of cases, the length of the prosthesis was 4.75 mm (62 patients, 48.1%), followed by 4.5 mm (29 patients, 22.5%) and 5 mm (27 patients, 20.9%). In eleven cases (8.5%) the prosthesis measured less than 4,5 mm. None of the patients in this study experienced a postoperative sensorineural hearing loss. The measurement of the length of the piston is very significant, and in our study the majority of the pistons were cut at 4.75 mm which indicates an incus-footplate measurement of 4.25 mm.

  15. Predictors of retention and attrition in a study of an advanced upper limb prosthesis: implications for adoption of the DEKA Arm.

    PubMed

    Resnik, Linda; Cancio, Jill; Klinger, Shana; Latlief, Gail; Sasson, Nicole; Smurr-Walters, Lisa

    2018-02-01

    The purpose was to identify factors associated with completion of the VA home study of the DEKA Arm. Design and methodological procedures used: Differences between groups were examined using chi-square and t-tests. A multivariable logistic regression model predicting completion was generated and odds ratios (OR) for significant variables calculated. Post-hoc analysis was performed to plot the receiver operating characteristics (ROC) curve. Participants who completed were more likely to be prosthesis users at study onset (p = .03), and less likely to have a history of musculoskeletal problems (p = .047). There were no statistically significant differences between groups who completed and those who did not in gender, race, veteran status, age, body mass index (BMI), weight, height, musculoskeletal pain at baseline, satisfaction with current prosthesis, type of prosthesis, or months of prosthesis use. Two variables, prosthesis use and history of musculoskeletal problems were significant at p < .10. The area under the curve (AUC) accuracy index was 0.78. We considered completion of the home use study a reasonable proxy for participant willingness to adopt the device; and believe that findings can be extrapolated to guide DEKA Arm prescription recommendations. Participants most likely to complete the study were already using a personal prosthesis, and without pre-existing musculoskeletal problems. Implications for rehabilitation Data from the VA Study of the DEKA Arm were analysed to determine which factors were associated with likely successful adoption of the DEKA Arm. Participants most likely to complete the study were those who already using a personal prosthesis, and those without pre-existing chronic or re-occurring musculoskeletal problems. This information may be useful when attempting to identify and target the most appropriate candidates for DEKA Arm prescription.

  16. [Comparison of early clinical effects of two hip prosthesis designs between ceramics to ceramics and metal to polyethylene].

    PubMed

    Yang, Li-qing; Li, Xi; Fu, Qin; Wang, Cheng

    2013-07-01

    To retrospectively study early therapeutic effects of the ceramics to ceramics prosthesis design in treating hip disease. From October 2007 to September 2010, 42 patients (44 hips) with hip disease underwent replacement of total hip. Hip prosthesis designs included the Pinnacle ceramics to ceramics and the Duraloc metal to polyethylene,produced by DePuy Company, all were non-bone cement type of artificial hip joint. Twenty patients (22 hips) were performed with ceramics to ceramics total hip prosthesis (CoC group, there were 12 males and 8 females, aged from 21 to 49 years) and 22 patients (22 hips) were performed with metal to polyethylene total hip prosthesis (MoP group, there were 13 males and 9 females, aged from 42 to 55 years). All the surgical approachs were posterolateral, and the routine anticoagulation and the corresponding functional exercise were performed after operation. The follow-up time was 6 months at least including clinical and radiographic observation. Measured the motion of joint and evaluated the function of hip joint according to Harris classification. All clinical effects were satisfactory and no dislocation ,loosening,infection, deep venous thrombosis and other complications occurred. There was no statistical significance in Harris scoring and the motion of joint between two groups before and after operation (P>0.05). The clinical effect of ceramics to ceramics prosthesis design in improving clinical symptoms and the motion of joint is coordinate with metal to polyethylene total hip prosthesis, however, its advantages and long-term efficacy need further observing. The ceramics to ceramics prosthesis design may be a good choice for the young patients with hip disease because of its good wear resistance.

  17. Utilization of penile prosthesis and male incontinence prosthetics in Saudi Arabia.

    PubMed

    Alwaal, Amjad; Al-Sayyad, Ahmad J

    2017-01-01

    Erectile dysfunction is a prevalent disease affecting over 50% of men between the ages of 40 and 70 years. Penile prosthesis represents the end of the line treatment when other less invasive therapies fail or are contraindicated. Male stress urinary incontinence can significantly diminish quality of life and lead to embarrassment and social withdrawal. Surgical therapies, such as male urethral slings and artificial urinary sphincters (AUS), are considered effective and safe treatments for male stress incontinence. No data exist on the utilization of penile prosthesis or male incontinence surgical treatment in Saudi Arabia. Generally, urological prosthetic surgery is performed either in private hospitals or in government hospitals. Our aim was to assess the trend of penile prosthesis and male incontinence device utilization in Saudi Arabia. We utilized sales' data of penile prosthetics, male slings, and AUS from the only two companies selling these devices in Saudi Arabia (AMS ® and Coloplast ® ), from January 2013 to December 2016. There were 2599 penile prosthesis implantation procedures done in the study period, with 67% of them performed in private institutions. There was a progressively increased use of penile prosthetics which nearly doubled from 2013 to 2016. The main type of prosthesis utilized was the semirigid type 70% versus 11% of the 2-piece inflatable and 17% of the 3-piece inflatable device. Only 10 slings and 31 AUS were inserted during the same study period. There is an increased utilization of penile prosthetics in Saudi Arabia. The private sector performs the majority of penile prosthesis procedures, and most of them are of the semirigid type. The governmental sector is more likely to perform inflatable penile prosthesis and male incontinence device procedures. Male incontinence prosthetics' use is very limited in Saudi Arabia.

  18. Automated estimation of hip prosthesis migration: a feasibility study

    NASA Astrophysics Data System (ADS)

    Vandemeulebroucke, Jef; Deklerck, Rudi; Temmermans, Frederik; Van Gompel, Gert; Buls, Nico; Scheerlinck, Thierry; de Mey, Johan

    2013-09-01

    A common complication associated with hip arthoplasty is prosthesis migration, and for most cemented components a migration greater than 0.85 mm within the first six months after surgery, are an indicator for prosthesis failure. Currently, prosthesis migration is evaluated using X-ray images, which can only reliably estimate migrations larger than 5 mm. We propose an automated method for estimating prosthesis migration more accurately, using CT images and image registration techniques. We report on the results obtained using an experimental set-up, in which a metal prosthesis can be translated and rotated with respect to a cadaver femur, over distances and angles applied using a combination of positioning stages. Images are first preprocessed to reduce artefacts. Bone and prosthesis are extracted using consecutive thresholding and morphological operations. Two registrations are performed, one aligning the bones and the other aligning the prostheses. The migration is estimated as the difference between the found transformations. We use a robust, multi-resolution, stochastic optimization approach, and compare the mean squared intensity differences (MS) to mutual information (MI). 30 high-resolution helical CT scans were acquired for prosthesis translations ranging from 0.05 mm to 4 mm, and rotations ranging from 0.3° to 3° . For the translations, the mean 3D registration error was found to be 0.22 mm for MS, and 0.15 mm for MI. For the rotations, the standard deviation of the estimation error was 0.18° for MS, and 0.08° for MI. The results show that the proposed approach is feasible and that clinically acceptable accuracies can be obtained. Clinical validation studies on patient images will now be undertaken.

  19. Linear morphological stability analysis of the solid-liquid interface in rapidsolidification of a binary system

    NASA Astrophysics Data System (ADS)

    Galenko, P. K.; Danilov, D. A.

    2004-05-01

    The interface stability against small perturbations of the planar solid-liquid interface is considered analytically in linear approximation. Following the analytical procedure of Trivedi and Kurz [

    R. Trivedi and W. Kurz, Acta Metall. 34, 1663 (1986)
    ], which is advancing the original treatment of morphological stability by Mullins and Sekerka [
    W. W. Mullins and R. F. Sekerka, J. Appl. Phys. 35, 444 (1964)
    ] to the case of rapid solidification, we extend the model by introducing the local nonequilibrium in the solute diffusion field around the interface. A solution to the heat- and mass-transport problem around the perturbed interface is given in the presence of the local nonequilibrium solute diffusion. Using the developing local nonequilibrium model of solidification, the self-consistent analysis of linear morphological stability is presented with the attribution to the marginal (neutral) and absolute morphological stability of a rapidly moving interface. Special consideration of the interface stability for the cases of solidification in negative and positive thermal gradients is given. A quantitative comparison of the model predictions for the absolute morphological stability is presented with regard to experimental results of Hoglund and Aziz [ D. E. Hoglund and M. J. Aziz, in Kinetics of Phase Transformations, edited by M.O. Thompson, M. J. Aziz, and G. B. Stephenson, MRS Symposia Proceedings No. 205 (Materials Research Society, Pittsburgh, 1991), p. 325 ] on critical solute concentration for the interface breakdown during rapid solidification of Si-Sn alloys.

  20. A laboratory silicone for preclinical training in ear prosthesis.

    PubMed

    Anand, Vijay; Haribabu; Vimala; Gnanasamband, Vimala

    2013-07-01

    This article describes an industrial elastic silicone as a material for the laboratory fabrication of ear prosthesis. It has been tested for toxicity in lab animals by the SGS India Pvt. Ltd and approved as a material to pass the parameter of abnormal toxicity. This material therefore can be safely recommended for laboratory exercise to fabricate facial prosthesis. The high cost of the maxillo facial silicone materials prohibits their use for facial prosthesis in pre-clinical training of post-graduate students in maxillofacial prosthodontics. For this reason, pre-clinical laboratory exercise in facial prosthesis is inadequate. A few institutions use polymethyl methacrylate resins which are rigid and do not have elastic characteristics of silicone, which is used for facial defects. This cost-effective industrial silicone material which mimics the elastic and color characteristics of the conventional silicones can be recommended for preclinical exercises.

Top