Science.gov

Sample records for kv transmission lines

  1. Wild Horse 69-kV transmission line environmental assessment

    SciTech Connect

    1996-12-01

    Hill County Electric Cooperative Inc. (Hill County) proposes to construct and operate a 69-kV transmission line from its North Gildford Substation in Montana north to the Canadian border. A vicinity project area map is enclosed as a figure. TransCanada Power Corporation (TCP), a Canadian power-marketing company, will own and construct the connecting 69-kV line from the international border to Express Pipeline`s pump station at Wild Horse, Alberta. This Environmental Assessment is prepared for the Department of Energy (DOE) as lead federal agency to comply with the requirements of the National Environmental Policy Act (NEPA), as part of DOE`s review and approval process of the applications filed by Hill County for a DOE Presidential Permit and License to Export Electricity to a foreign country. The purpose of the proposed line is to supply electric energy to a crude oil pump station in Canada, owned by Express Pipeline Ltd. (Express). The pipeline would transport Canadian-produced oil from Hardisty, Alberta, Canada, to Caster, Wyoming. The Express Pipeline is scheduled to be constructed in 1996--97 and will supply crude oil to refineries in Wyoming and the midwest.

  2. Context view of RyantoRainbow 100kv Transmission Line showing copper wire ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Context view of Ryan-to-Rainbow 100kv Transmission Line showing copper wire conductors leaving roof of Ryan Powerhouse. View to east - Ryan Hydroelectric Facility, Ryan-to-Rainbow 100 kV Transmission Line, West bank of Missouri River, northeast of Great Falls, Great Falls, Cascade County, MT

  3. 75 FR 75170 - Minnkota Power Cooperative, Inc.: Bemidji to Grand Rapids 230 kV Transmission Line Project

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-02

    ... Rural Utilities Service Minnkota Power Cooperative, Inc.: Bemidji to Grand Rapids 230 kV Transmission... to Grand Rapids 230 kV Transmission Line Project (Project) in Beltrami, Hubbard, Itasca, and Cass... construct the 230 kilovolt (kV) transmission line between the Wilton Substation near Bemidji, Minnesota...

  4. First structure on MoronytoRainbow 100kV Transmission Line below Morony Dam ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    First structure on Morony-to-Rainbow 100kV Transmission Line below Morony Dam and Power House. Three-pole H-frame structure with historic porcelain suspension insulators, jumper supports insulators, overhead ground wires, and pole stubs. View to east-northeast - Morony Hydroelectric Facility, Morony-to-Rainbow 100 kV Transmission Line, West bank of the Missouri River, Great Falls, Cascade County, MT

  5. Marys Lake 69/115-kV transmission line upgrade and substation expansion projects

    SciTech Connect

    1996-05-01

    Western Area Power Administration (Western) and the Platte River Power Authority (Platte River) propose to upgrade portions of the existing electric transmission and substation system that serves the Town of Estes Park, Colorado. The existing transmission lines between the Estes Power Plant Switchyard and the Marys Lake Substation include a 115,000 volt (115-kV) line and 69,000 volt (69-kV) line. Approximately one mile is a double-circuit 115/69-kV line on steel lattice structures, and approximately two miles consists of separate single-circuit 115-kV and a 69-kV lines, constructed on wood H-Frame structures. Both lines were constructed in 1951 by the US Bureau of Reclamation. The existing transmission lines are on rights-of-way (ROW) that vary from 75 feet to 120 feet and are owned by Western. There are 48 landowners adjacent to the existing ROW. All of the houses were built adjacent to the existing ROW after the transmission lines were constructed. Upgrading the existing 69-kV transmission line between the Marys Lake Substation and the Estes Power Plant Switchyard to 115-kV and expanding the Marys Lake Substation was identified as the most effective way in which to improve electric service to Estes Park. The primary purpose and need of the proposed project is to improve the reliability of electric service to the Town of Estes Park. Lack of reliability has been a historical concern, and reliability will always be less than desired until physical improvements are made to the electrical facilities serving Estes Park.

  6. Hayden-Blue River 345-kV transmission line project, Colorado

    SciTech Connect

    Not Available

    1982-09-01

    Tri-State Generation and Transmission Association, Inc., Colorado-Ute Electric Association, Inc., Platte River Power Authority, and Western Area Power Administration propose to construct and operate approximately 90 miles of 345-kilovolt (kV) transmission line between Hayden and the Blue River Valley in Colorado. The project would involve expansion of existing substation facilities at Hayden and construction of two new substations. The line would be operated at 230 kV initially. Estimated cost of the project is $37.8 million. The new line and substation facilities would provide a backup transmission path, satisfy the long-term needs in meeting the energy requirements, improve system reliability, improve system stability for the Craig and Hayden generating stations, and leave the existing 115-kV and 138-kV lines in operation to provide additional transmission capacity that would function as backup transmission during an outage on another line. Minute amounts of lands would be displaced. Construction activities would disturb critical ranges for elk and mule deer, elk calving areas, and the mating and nesting areas of greater sandhill cranes, great blue herons, sage grouse, golden eagles, and prairie falcons. Management of timberland would damage natural vegetation. The line would traverse 3.1 miles of flood-prone area, and as many as three transmission towers would lie within the floodplain of the Colorado River. The visual quality of land crossed by the line would be degraded somewhat.

  7. Research on safety protection for live working on ±800kV DC transmission line with AC and DC multi-circuit transmission lines

    NASA Astrophysics Data System (ADS)

    Xie, Yan; Xiang, Tao; Li, Mu

    2017-04-01

    In recent years, in order to save line corridors and reduce the scope of demolition, some new transmission modes for high voltage AC and DC power transmission line are proposed. According to the characteristics of the parallel transmission line, this paper studies the distribution characteristics of the electric field intensity of multi circuit parallel transmission lines and the single circuit transmission line. Comparing and analysing the simulation results of the electric field strength, the safety measures for live working of ±800kV DC transmission line with multi circuit parallel transmission lines is put forward. That is the electric field protective equipment and measures used in the live line work of the ±800kV UHDC single circuit line can meet the requirements of the live operation of the ±800kV UHDC multi-circuit transmission line.

  8. Research on Safety Protection for Live Working on 1000kV AC Transmission Line with AC and DC Multi-circuit Transmission Lines

    NASA Astrophysics Data System (ADS)

    Xie, Yan; Li, Mu; Xiang, Tao

    2017-05-01

    In recent years, in order to save line corridors and reduce the scope of demolition, some new transmission modes for high voltage AC and DC power transmission line are proposed. According to the characteristics of the parallel transmission line, this paper studies the distribution characteristics of the electric field intensity of multi circuit parallel transmission lines and the single circuit transmission line. Comparing and analysing the simulation results of the electric field strength, the safety measures for live working of 1000kV AC transmission line with multi circuit parallel transmission lines is put forward. That is the electric field protective equipment and measures used in the live line work of the 1000kV UHV AC single circuit line can meet the requirements of the live operation of the 1000kV UHV AC double circuit line.

  9. Survey of Magnetic Fields Near BPA 230-kV and 500-kV Transmission Lines.

    SciTech Connect

    Perrin, Nancy; Aggarwal, Rajinder Pal; Bracken, T. Daniel

    1991-05-20

    The purpose of this study was to characterize typical levels and variability of 60Hz magnetic fields at the centerline and edge of right-of-way of Bonneville Power Administration (BPA) 230-kV and 500-kV transmission lines. This was accomplished by taking magnetic field measurements at over 800 spans in Oregon and Washington. The spans were sampled using a stratified random sampling procedure with region (East vs. West), voltage (230-kV vs 500-kV), and circuit configuration as strata. There were five different circuit configuration groups for each region/voltage category requiring a total of 200 strata. Magnetic field measurements were taken at 13 locations under each span using an EMDEX-C as a survey meter. Additional information recorded for each span included conductor height (at 10 locations), right-of-way width, longitudinal and lateral slope, time of day, vegetation, terrain, weather conditions, temperature, wind speed, span length and presence of other lines in the corridor. 9 refs., 17 figs., 26 tabs.

  10. 75 FR 32357 - Gallatin National Forest; Montana; Jack Rabbit to Big Sky Meadow Village 161 kV Transmission Line...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-08

    ... resources Visual resources/Scenery Human health and safety (including electric and magnetic fields... impact statement (EIS) to consider potential effects of a proposed project by NorthWestern Energy to rebuild an existing 69- kilovolt (kV) electric transmission line to a 161-kV electric transmission line...

  11. Grand Coulee - Bell 500-kV Transmission Line Project, Draft Environmental Impact Statement

    SciTech Connect

    N /A

    2002-08-09

    BPA is proposing to construct a 500-kilovolt (kV) transmission line that would extend approximately 84 miles between the Grand Coulee 500-kV Switchyard, near Grand Coulee Dam, and the Bell Substation, in Mead just north of Spokane. The new line would cross portions of Douglas, Grant, Lincoln, and Spokane counties. In addition to the transmission line, new equipment would be installed at the substations at each end of the new line and at other facilities. The proposed action would remove an existing 115-kV transmission line and replace it with the new 500-kV line on existing right-of-way for most of its length. Additional right-of-way would be needed in the first 3.5 miles out of the Grand Coulee Switchyard to connect to the existing 115-kV right-of-way. Since the mid-1990s, the transmission path west of Spokane, called the West of Hatwai transmission pathway, has grown increasingly constrained. To date, BPA has been able to manage operation of the path through available operating practices, and customer needed have been met while maintaining the reliability of the path. however, in early 2001, operations showed that the amount of electricity that needs to flow from east to west along this path creates severe transmission congestion. Under these conditions, the system is at risk of overloads and violation of industry safety and reliability standards. The problem is particularly acute in the spring and summer months because of the large amount of power generated by dams east of the path. Large amounts of water cannot be spilled during that time in order for BPA to fulfill its obligation to protect threatened and endangered fish. The amount of power that needs to move through this area during these months at times could exceed the carrying capacity of the existing transmission lines. In additional capacity is not added, BPA will run a significant risk that it will not be able to continue to meet its contractual obligations to deliver power and maintain reliability

  12. Long Term Field Test of Polymer Insulator on 77kV Transmission Line

    NASA Astrophysics Data System (ADS)

    Tanaka, Nobuya; Kuroyagi, Toshiyuki; Niihara, Sadao

    As an anti-Vandalism measure, polymer insulator which is light and shows good performance in contamination withstand voltage is already adopted to many new power transmission lines mainly in U.S.A. However, it is said that aging deterioration is promoted by ultraviolet rays, ozone, leakage current and partial discharge because polymer insulator is made of organic materials. It is important that we seize the characteristics of aging deterioration to maintain power transmission lines. As polymer insulator for power transmission lines is more expensive than ceramic one, it is scarely used in Japan, and there is no data in the field. In this study, we installed polymer insulator to 77kV power transmission line and carried out field test for nine years from 1997 to 2006 and investigated electrical and mechanical characteristics of them.

  13. Craig-Bonanza 345-kV Transmission Line Project: Environmental assessment

    SciTech Connect

    Not Available

    1988-01-01

    The Department of Energy (DOE), and the Western Area Power Administration (Western) proposes to construct and maintain a 345- kilovolt (kV) transmission line between Craig, Colorado, and Bonanza in eastern Utah. The project began in 1986 and construction is scheduled to be completed in 1989. The project, known as the Craig-Bonanza 345-kV Transmission Line Project (Project), will be located in Moffat and Rio Blanco counties in Colorado and Uintah County in Utah. Western has the lead role for project development and management, including environmental studies and construction. Cooperating federal agencies include the Bureau of Land Management (BLM), Rural Electrification Administration, US Fish and Wildlife Service, and Bureau of Indian Affairs. This environmental assessment was prepared in compliance with the National Environmental Policy Act (NEPA) and the regulations of the Council on Environmental Quality (CEQ), the DOE and the BLM. 360 refs., 33 figs., 21 tabs.

  14. Sidney-North Yuma 230-kV Transmission Line Project, Colorado and Nebraska

    SciTech Connect

    Not Available

    1991-06-01

    This report describes the need for a 230-kV overhead transmission line to supply power from Sidney, Nebraska to eastern Colorado. The alternative scenario compared to construction of the line is No Action. Rejected alternatives include underground lines and different routing paths, with a possible extension to the Sterling area. Both scenarios are evaluated for environmental effects, cost, and consequences for the eastern Colorado region. The proposed route is determined to be the environmentally preferred choice. 120 refs., 6 figs., 13 tabs. (MHB)

  15. Weld-Windsor 115-kV Transmission Line Project, Weld County, Colorado

    SciTech Connect

    1996-05-01

    The Western Area Power Administration is proposing to rebuild a 3.0 mile segment of the existing Flatiron-Weld 115-kV transmission line in Weld County. The line would be reconductored with new conductor on new wood pole double circuit structures. The new structures would support a double circuit transmission line configuration. The first circuit would be owned by Western and the second by Public Service Company of Colorado (PSCO). Alternatives considered included no action, constructing PSCO`s circuit on new right-of-way, and reconductoring Western`s existing line on the same structures. The proposed action was selected because it provided an opportunity to share structures with PSCO and, overall, would minimize costs and environmental impacts. The environmental assessment identifies minor effects on existing natural or human resources and minor benefits for agricultural operations.

  16. AC and lightning performance of fiberglass crossarms aged in 115 kV transmission line

    SciTech Connect

    Grzybowski, S. . Dept. of Electrical and Computer Engineering); Jenkins, E.B. . Generation and Transmission Group)

    1993-10-01

    This paper presents the results of an investigation of the electrical performance of 115 kV transmission line fiberglass cross-arm used by Mississippi Power and Light Company. A transmission line fiberglass crossarm removed from service and companion cross-arms outdoors but not in service were examined. The evaluation of electrical performance was based on flashover voltage value at AC voltage and standard lightning impulses as well as under dry and wet conditions. The tests were performed in the Mississippi State University High Voltage Laboratory. The obtained flashover voltages show no large differences in electrical strength of fiberglass crossarms removed from service and those stored outdoors. The Added CFO voltage by fiberglass crossarm to the porcelain suspension insulators is presented versus the length of the fiberglass crossarm for dry and wet conditions.

  17. Final environmental assessment: Los Reales 115 kV transmission line alternative routes

    SciTech Connect

    Not Available

    1989-10-01

    The Central Arizona Project (CAP) was authorized as a part of the Colorado River Basin Project Act (Public Law 90-537) on September 30, 1968. The primary purpose of the CAP is to furnish water for agricultural, municipal, and industrial uses in central and southern Arizona, and western New Mexico. Due to its magnitude, the CAP is divided into several major features serving separate but interrelated functions. The Tucson Aqueduct Phase B pumping plants were designed and constructed to operate on a looped power system. The entire looped power system, including two switching stations and connecting 115-kv transmission lines, was identified in the FEIS and approved for construction in the Secretary of Interior's Record of Decision dated September 24, 1985. The loop begins in the vicinity of the Twin Peaks Pumping Plant -- the northernmost Phase B pumping station, at the Rattlesnake Switching Station. All of the looped power system has been constructed with the exception of the switching station and portion of transmission line proposed to be constructed in this project. Without construction of this final portion of the looped power system, the Phase B pumping plants will not be able to operate normally without negatively affecting nearby power sources. The CAP will also not be able to provide the reliability necessary for municipal water systems dependent upon CAP water. The purpose of this EA is to describe impacts that would result from relocating the Los Reales 115-kV transmission line, and possibly the switching station, originally identified in the FEIS. It should be mentioned the Department of Energy will complete a separate NEPA review.

  18. Environmental Assessment of the Gering-Stegall 115-kV Transmission Line Consolidation Project, Scotts Bluff County, Nebraska

    SciTech Connect

    1995-05-01

    The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmission lines near the Gering Substation in Gering, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmission lines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmission line and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV transmission lines on to one ROW for a 1.33-mile segment between the Gering Substation and a point west of the Gering Landfill. All existing wood-pole H-frame structures would be removed, and the Gering-Stegall North and South ROWs abandoned. Western is responsible for the design, construction, operation, and maintenance of the line. Western prepared an environmental assessment (EA) that analyzed the potential environmental impacts of the proposed construction, operation, and maintenance of the 115-kV transmission line consolidation. Based on the analyses in the EA, the DOE finds that the proposed action is not a major Federal action significantly affecting the quality of the human environment, within the meaning of the National Environmental Policy Act of 1969 (NEPA).

  19. Engineering analysis of electrical effects for the COTP 500KV transmission line and EBMUD aqueduct corridor

    SciTech Connect

    Lewis, O.C.; Bell, G.K.; Ma, J.

    1995-12-31

    A study was conducted to determine AC electrical interference effects arising in the East Bay Municipal Utility District`s (EBMUD) Mokelumne Aqueducts due to their proximity to the Olinda-Tracy 500 kilovolt (kV) transmission line operated by the Western Area Power Administration (WESTERN). A six-wire gradient control wire mitigation system selected by EBMUD was modeled and evaluated. The study shows that the mitigation system performs satisfactorily under all conditions examined. During steady state conditions, touch voltages are maintained below 15 volts throughout the entire length of the three aqueducts. During fault conditions, touch voltages are maintained below 263 volts, the design limit calculated according to ANSI/IEEE Standard 80. The currents flowing through the isolator/surge protectors do not exceed the ratings of these devices, during steady state and fault conditions.

  20. Big George to Carter Mountain 115-kV transmission line project, Park and Hot Springs Counties, Wyoming. Environmental Assessment

    SciTech Connect

    Not Available

    1994-02-01

    The Western Area Power Administration (Western) is proposing to rebuild, operate, and maintain a 115-kilovolt (kV) transmission line between the Big George and Carter Mountain Substations in northwest Wyoming (Park and Hot Springs Counties). This environmental assessment (EA) was prepared in compliance with the National Environmental Policy Act (NEPA) and the regulations of the Council on Environmental Quality (CEQ) and the Department of Energy (DOE). The existing Big George to Carter Mountain 69-kV transmission line was constructed in 1941 by the US Department of Interior, Bureau of Reclamation, with 1/0 copper conductor on wood-pole H-frame structures without an overhead ground wire. The line should be replaced because of the deteriorated condition of the wood-pole H-frame structures. Because the line lacks an overhead ground wire, it is subject to numerous outages caused by lightning. The line will be 54 years old in 1995, which is the target date for line replacement. The normal service life of a wood-pole line is 45 years. Under the No Action Alternative, no new transmission lines would be built in the project area. The existing 69-kV transmission line would continue to operate with routine maintenance, with no provisions made for replacement.

  1. 75 FR 3486 - Susquehanna to Roseland 500kV Transmission Line, Environmental Impact Statement, Delaware Water...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-21

    ... Pennsylvania Power and Light Electric Utilities (PPL) and Public Service Electric and Gas Company (PSE&G), and... single 230 kV power line and towers currently on the right-of-way would be removed and replaced with... the grid at the direction of the Regional Transmission Operator, PJM Interconnection (PJM)....

  2. Folsom-Nimbus 115 kV transmission line replacement for Western Area Power Administration: Environmental assessment

    SciTech Connect

    Not Available

    1980-07-01

    The Western Area Power Administration (Western) proposes to replace the existing Folsom-Nimbus 115 kV electrical transmission line along the American River between Folsom Dam and Nimbus Dam in Sacramento County, California. The need to replace the line is attributed to the deterioration of the existing wood pole structures by the acorn woodpecker; thus resulting in increased maintenance and hazard potential. The need for the replacement of the Folsom-Nimbus transmission line has resulted in the evaluation by Western of various routing alternatives. These alternatives were evaluated in terms of design, economic and environmental considerations. 60 refs., 19 figs., 4 tabs.

  3. Research for the calculation of the potential transfer energy on ±800kV DC Transmission Lines

    NASA Astrophysics Data System (ADS)

    Ren, Huisong; Wang, Hui; Gao, Liyuan; Li, Jinliang

    2017-07-01

    It would be hard to be repaired in the case of a power outage if the ±800kV ultra high voltage DC (UHVDC) transmission line was put into operation, so live working is the guarantee for its security and stability. It’s necessary to calculate potential transfer energy to ensure the safety of the live working personnel. The transfer energy can be calculated by establishing the equivalent model of the process of potential transfer. Potential differences and capacitance parameters can be calculated by the finite element method, thereby transfer energy in different transfer distances can be worked out. The results show that the transfer energy increases with the increase of the transfer distance and the transfer energy reaches to 1.0 J when the distance is 0.5 m. So the potential transfer rod is necessary for the security of the live working personnel on ±800kV DC transmission lines.

  4. Coyote Pumping Plant 115-kV transmission line project, Santa Clara County, California: Environmental assessment

    SciTech Connect

    Not Available

    1985-01-01

    Environmental impacts expected from the design and siting of transmission lines and the associated pumping plant station are addressed with alternative routes and actions considered, in compliance with environmental laws. (PSB)

  5. Seasonal Patterns of Melatonin, Cortisol, and Progesterone Secretion in Female Lambs Raised Beneath a 500-KV Transmission Line

    NASA Astrophysics Data System (ADS)

    Lee, Jack Monroe, Jr.

    There is ongoing controversy about the possibility of adverse biological effects from environmental exposures to electric and magnetic fields. These fields are produced by all electrical equipment and appliances including electrical transmission lines. The objective of this environmental science study was to investigate the possible effects of a high voltage transmission line on domestic sheep (Ovis aries L.), a species that can often be found near such lines. The study was primarily designed to determine whether a specific effect of electric and magnetic fields found in laboratory animals also occurs in livestock under natural environmental conditions. The effect is the ability of fields, at levels found in the environment, to significantly depress the normally high nocturnal concentrations of the pineal hormone-melatonin. Ten female Suffolk lambs were penned for 10 months directly beneath a 500-kV transmission line near Estacada, Oregon. Ten other lambs of the same type were penned in a control area away from the transmission line where electric and magnetic fields were at ambient levels. Serum melatonin was analyzed by radioimmunoassay (RIA) from 6618 blood samples collected at 0.5 to 3-hour intervals over eight 48-hour periods. Serum progesterone was analyzed by RIA from blood samples collected twice weekly. Serum cortisol was also assayed by RIA from the blood samples collected during the 48-hour samples. Results showed that lambs in both the control and line groups had the typical pattern of melatonin secretion consisting of low daytime and high nighttime serum concentrations. There were no statistically significant differences between groups in melatonin levels, or in the phase or duration of the nighttime melatonin elevation. Age at puberty and number of reproductive cycles also did not differ between groups. Serum cortisol showed a circadian rhythm with highest concentrations during the day. There were, however, no differences in cortisol concentrations

  6. Seasonal Patterns of Melatonin, Cortisol, and Progesterone Secretion in Female Lambs Raised Beneath a 500-kV Transmission Line.

    SciTech Connect

    Lee, Jack M.

    1992-06-01

    Although several kinds of biological effects of electric and magnetic fields have been reported from laboratory studies, few have been independently replicated. When this study was being planned, the suppression of nighttime melatonin in rodents was thought to represent one of the strongest known effects of these fields. The effect had been replicated by a single laboratory for 60-Hz electric fields, and by multiple laboratories for d-c magnetic fields. The primary objective of this study was to determine whether the effect of electric and magnetic fields on melatonin would also occur in sheep exposed to a high voltage transmission line. The specific hypothesis tested by this experiment was as follows: The electrical environment produced by a 60-Hz, 500-kV transmission line causes a depression in nocturnal melatonin in chronically exposed female lambs. This may mimic effects of pinealectomy or constant long-day photoperiods, thus delaying the onset of reproductive cycles. Results of the study do not provide evidence to support the hypothesis. Melatonin concentrations in the sheep exposed to the transmission line showed the normal pattern of low daytime and high nighttime serum levels. As compared to the control group, there were no statistically significant group differences in the mean amplitude, phase, or duration of the nighttime melatonin elevation.

  7. Application of portable protective gaps for live work on compact 550 kV transmission lines

    SciTech Connect

    Gela, G.; Lux, A.E.; Kientz, H.; Gillies, D.A.; Mitchell, J.D.; Lyons, P.F.

    1996-07-01

    This paper presents result of research on the application of a Portable Protective Gap (PPG) to live work on a compact 550 kV steel lattice tower. The objective of the research was to provide experimental evidence which confirms the needed coordination of the PPG sparkover characteristics with the sparkover characteristics of the worksite on the compact tower during live work. Sparkover characteristics of the worksite are strongly affected by the presence of the worker, the live working tools, and damaged insulators.

  8. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-40) - Allston-Keeler 500 kV Transmission Line

    SciTech Connect

    Hermeston, Mark W.

    2002-02-19

    Vegetation Management along the Allston-Keeler 500 kV Transmission Line ROW exclusive to BLM lands between 8/4 through 27/4. The proposed work will be accomplished in the indicated sections of the transmission line corridor with an average corridor width of 150 feet. BPA proposes to clear unwanted vegetation in the rights-of-ways and around tower structures that may impede the operation and maintenance of the subject transmission lines and access roads, including Reclaim and Danger Trees. The lands in this SA are administered by BLM. BPA plans to conduct vegetation control with the goal of removing tall growing vegetation that is currently or will soon be a hazard to the transmission line. BPA’s overall goal is to have low-growing plant communities along the rights-of-way to control the development of potentially threatening vegetation. All work will be executed in accordance with the National Electrical Safety Code and BPA standards. Work is to begin in March 2002. In accordance with a court injunction, no chemical treatment is planned on BLM lands.

  9. Proposal to amend existing operating permit for the Ault-Craig 345-kV and Hayden-Archer 230-kV transmission lines, Routt, Jackson and Larimer Counties, Colorado

    SciTech Connect

    1997-08-01

    The Western Area Power Administration, Rocky Mountain Region, is proposing to amend an existing US Forest Service operating permit for the Ault-Craig 345-kV and Hayden-Archer 230-kV transmission lines, which are located in Routt, jackson, and Larimer counties, Colorado. These transmission lines cross portions of the Roosevelt and Routt National Forests. The long-term use authorization Western is requesting from the Forest Service would be for the life of the Ault-Craig and Hayden-Archer transmission lines. This environmental assessment addresses those access road and right-of-way maintenance activities identified by Western that would be performed on Forest Service managed lands during the next approximately five years.

  10. Environmental Assessment and Finding of No Significant Impact: Curecanti-Lost Canyon 230-kV Transmission Line Reroute Project, Montrose County, Colorado

    SciTech Connect

    N /A

    2000-03-20

    The Department of Energy (DOE), Western Area Power Administration (Western) is proposing to reroute a section of the Curecanti-Lost Canyon 230-kilovolt (kV) transmission line, in Montrose County, Colorado. A portion of the transmission line, situated 11 miles southeast of Montrose, Colorado, crosses Waterdog Peak, an area of significant geologic surface activity, which is causing the transmission line's lattice steel towers to shift. This increases stress to structure hardware and conductors, and poses a threat to the integrity of the transmission system. Western proposes to relocate the lattice steel towers and line to a more geologically stable area. The existing section of transmission line and the proposed relocation route cross Bureau of Land Management and private land holdings.

  11. Curecanti-Blue Mesa-Salida 115-kV transmission lines access roads rehabilitation, maintenance, and construction project. Environmental Assessment

    SciTech Connect

    Not Available

    1993-07-01

    Western Area Power Administration (Western) is a power marketing agency of the US Department of Energy, with jurisdiction in 15 western states. The Salt Lake City Area (SLCA) of Western performs the agency`s mission in parts of Colorado, New Mexico, Texas, Utah, Arizona, Wyoming, and Nevada. As part of its mission, Western owns, operates, and maintains a system of transmission lines for transmitting bulk electrical energy from points of generation to and between delivery points. Part of that system in southwestern Colorado includes the Blue Mesa-Curecanti and Blue Mesa-Salida 115-kV transmission lines. Western proposes to conduct maintenance and improve its access roads for these two transmission lines. This paper discusses the impacts to the existing environment as well as the environmental consequences resulting from the maintenance and construction that is proposed.

  12. Longitudinal load and cascading failure risk assessment (CASE): Tennessee Valley Authority`s 161-kV Lowndes-West Point transmission line. Final report

    SciTech Connect

    Ostendorp, M.

    1998-03-01

    The Electric Power Research Institute`s (EPRI) Cascading Failure Risk Assessment (CASE) methodology was used to determine extreme event, unbalanced loads on Tennessee Valley Authority`s (TVA) 161-kV, single circuit, Lowndes-West Point transmission line and to identify the cascading potential of the line under five different loading conditions. More specifically, TVA wanted to evaluate the cascading potential of the Type HS-1G and BHS-1G tangent structures which comprise the majority of the line. While other cascading assessment methods primarily focus on the magnitude of the unbalanced loads acting on the first structure from the initiating event, EPRI`s CASE method incorporates the dynamic response and damping characteristics of the transmission line to determine the unbalanced longitudinal loads at any structure away from the initiating failure event. The CASE application constituted an investigation into the nature of the extreme loads that are expected to occur on the 161-kV Lowndes-West Point transmission line during a cascading failure and the corresponding dynamic response. The goals of the investigation were: to quantify unbalanced longitudinal loads acting on structures adjacent to the broken insulator, shield wire, or conductor failure as well as down-line structures; to assess the cascading potential of the Lowndes-West Point transmission line by considering the energy dissipation at successive spans and supports. The results of the CASE method indicate that the lack of longitudinal strength of the Type HS-1G and BHS-1G steel pole H-frame coupled with the dynamic characteristics of the Lowndes-West Point line was likely to result in a cascading failure for the more severe initiating event and load case combinations.

  13. Longitudinal load and cascading failure risk assessment (CASE): Bonneville Power Administration`s 230/500-kV Longview-Olympia transmission line. Final report

    SciTech Connect

    Ostendorp, M.

    1998-12-01

    The Electric Power Research Institute`s (EPRI) Cascading Failure Risk Assessment (CASE) methodology was used to determine extreme event, unbalanced loads on Bonneville Power Administration`s (BPA) 230/500-kV, single circuit, Longview-Olympia transmission line and to identify the cascading potential of the line under five different loading conditions. More specifically, BPA wanted to evaluate the cascading potential of the Type 2L, Type 2A1, and Type 238M tangent structures which comprise a significant portion of the line. While other cascading assessment methods primarily focus on the magnitude of the unbalanced loads acting on the first structure from the initiating event, EPRI`s CASE method incorporates the dynamic response and damping characteristics of the transmission line to determine the unbalanced longitudinal loads at any structure away from the initiating failure event. The CASE application constituted an investigation into the nature of the extreme loads that are expected to occur on the 230/500-kV Longview-Olympia transmission line during a cascading failure and the corresponding dynamic response. The goals of the investigation were: to quantify unbalanced longitudinal loads acting on structures adjacent to the broken insulator, shield wire, or conductor failure as well as down-line structures; and to assess the cascading potential of the Longview-Olympia transmission line by considering the energy dissipation at successive spans and supports. The results of the CASE method showed that BPA`s longitudinal loading criteria for the Type 2L, 2A1, and 238 M lattice towers satisfy BPA`s containment failure design philosophy with the addition of fiber optic cable. BPA`s longitudinal loading criteria applied simultaneously with extreme ice or wind does not provide adequate strength to prevent a cascade of less than ten towers.

  14. The 300-kV international submarine transmission line: Erie, Pennsylvania to Nanticoke, Ontario, Canada, General Public Utilities Corporation

    NASA Astrophysics Data System (ADS)

    1982-05-01

    This final environmental impact statement (FEIS) was prepared by the Office of Energy Emergency Operations. The proposed action by the Department of Energy is the granting of a Presidential Permit for the construction, connection, operation, and maintenance of 69.6 kilometers (44 miles) of a +250 to +325 and -250 to -325 kilovolt (250 to 325 kV) transmission facility from the Erie West Substation to the international border. The proposed project will connect the General Public Utilities Corporation System with the Ontario Hydro System for the purpose of economic exchanges of power and increased reliability. Environmental impacts expected from construction and operation of the proposed Lake Erie Interconnection appear to be mainly transitory effects on aquatic life due to construction.

  15. Analysis of Safety Protection Measures for Maintenance Work of 500 kV Double-Circuit Transmission Lines on Same Tower

    NASA Astrophysics Data System (ADS)

    Yang, Qi; Zou, Dehua; Zhang, Jianjun; Li, Hui; Chen, Jianping; Li, Jinliang

    2017-05-01

    Four transmission lines on the same tower are widely used because of their obvious economic and social benefits. But it also has high power supply reliability, so the choice of reasonable maintenance mode is particularly important. In this paper, we deducted the maintenance influence of the energized line to non-energized line, calculated and analyzed protection measures of non-energized singular line of 500kV double-circuit transmission line on the same tower with ATP software, and calculated field intensity distribution of typical operating position of the energized double-circuit transmission line with the finite element software. The calculation shows that when using the outage maintenance method, hanging both ground current and personal security line can reduce the current flowing through the operator’s body effectively. When using the live maintenance method, the field intensity of operator body strengths up to 383.69kV/m, The operator needs to wear shielding cloth with at least 43.08 dB shielding efficiency, in order to meet the security requirements.

  16. Environmental Assessment for Central Power and Light Company`s proposed Military Highway-CFE tie 138/69-kV transmission line project Brownsville, Cameron County, Texas

    SciTech Connect

    Not Available

    1992-04-01

    Central Power and Light Company (CPL) intends to upgrade its existing transmission line ties with the Commision Federal de Electricidad (CFE) system in Mexico. CPL currently has a single 69-kilovolt (kV) transmission line in the Brownsville area which connects CPL`s system with the system of CFE. This existing line runs between the Brownsville Switching Station, located on Laredo Road in Brownsville, Cameron County, Texas, and an existing CFE 69-kV line at the Rusteberg Bend of the Rio Grande in Cameron County. Under current conditions of need, the existing 69-kV line does not possess sufficient capability to engage in appropriate power exchanges. Therefore, CPL is proposing to build a new line to link up with CFE. This proposed line would be a double-circuit line, which would (1) continue (on a slightly relocated route) the existing 69-kV tie from CPL`s Brownsville Switching Station to CFE`s facilities, and (2) add a 138-kV tie from the Military Highway Substation, located on Military Highway (US Highway 281), to CFE`s facilities. The proposed 138/69-kV line, which will be constructed and operated by CPL, will be built primarily on steel single-pole structures within an average 60-foot (ft) wide right-of-way (ROW). It will be approximately 6900--9200 ft (1.3--1.7 miles) in length, depending on the alternative route constructed.

  17. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-221) Project #: V-O-04/10 - Paul-Allston No 1 and 2 - 500 kV Transmission Line Corridor

    SciTech Connect

    Stratton, Elaine S.

    2004-07-26

    The project activities will be conducted along the Right-of-Way (ROW) of the Paul-Allston No 1 and 2 - 500 kV transmission line corridor between towers 45/4 and the Allston substation. This corridor includes portions of the Longview-Allston No 1 and 2 and the Longview-Allston No 3 and 4 - 230 kV transmission lines. The corridor along this section of the proposed project varies between 125 and 150 feet in width and crosses approximately 4 miles of terrain from Longview, Washington crossing the Columbia River and passing through rural forestland and pasture lands to the Allston Substation in Oregon. BPA proposes to remove unwanted vegetation along the right-of-way, along access roads and around tower structures along the subject transmission line corridor that may impede the operation and maintenance of the identified transmission lines. BPA plans to conduct vegetation control with the goal of removing tall growing vegetation that is currently or will soon be a hazard to the transmission line. BPA’s overall goal is to have low-growing plant communities along the rights-of-way to control the development of potentially threatening vegetation.

  18. Research for the Working Method of Live Replacing the L-type Insulator String on ±800kV DC Transmission Lines

    NASA Astrophysics Data System (ADS)

    Li, Jinliang; Wang, Zhigang; Lei, Dongyun; Yang, Miao; Xia, Zengming; Xiang, Yun; Yan, Yu; Liu, Zhiguo

    2017-07-01

    It would be hard to be repaired in the case of a power outage if the ±800kV ultra high voltage DC (UHVDC) transmission line was put into operation, so live working is the guarantee for its security and stability. Insulator strings of duplex L-type are widely used in UHVDC small angle towers. In the meantime, the tower structure and the insulator strings’ arrangement type is different than the V-type. In order to ensure the security and stability of the transmission line, this paper presents a method of live replacing the duplex L-type insulators based on the actual parameter of the UHVDC L tower type and develops apparatus as a complementary supporting by mechanics analysis. In order to ensure the safety of working staff, the safe distance and combined gap of the hanging basket method are checked. Safety precautions are also proposed in the paper by the calculation of body surface field strength of the persons doing live working in the finite element method. It is shown by the field application that the live working task of replacing the L-type insulator strings can be accomplished successfully by the method put forward in this paper, which provides reference for the following live working on the UHV transmission line.

  19. Buffalo Flat Service 115-KV Transmission Project : Environmental Assessment.

    SciTech Connect

    United States. Bonneville Power Administration.

    1987-07-01

    The US Air Force has sited a radar transmitter at Buffalo Flat, near Christmas Valley, Oregon. This report discusses the environmental impacts of providing the electrical service for the installation. A 115 kV power transmission line will be built between LaPine and Buffalo Flat. Route alternatives as well as design alternatives are discussed. (ACR)

  20. Proposed amendment for Presidential Permit PP-63 and associated modifications to 500 kV international transmission line, Forbes, Minnesota to Manitoba, Canada Northern States Power Company. Final Environmental Assessment

    SciTech Connect

    Not Available

    1992-02-01

    Northern States Power Company, (NSP), a Minnesota investor owned utility has applied to the Office of Fossil Energy, United States Department of Energy, to amend Presidential Permit PP-63 to allow for alterations to the 500 kV transmission line and as sedated facilities currently regulated by this permit. The alterations proposed for the 500 kV line owned by NSP are part of a long term effort sponsored by NSP to upgrade the existing NSP transmission system to allow for increased exchange of electricity with the Manitoba Hydro-Electric Board. Presidential Permit PP-63 authorized NSP to construct, connect, operate and maintain a 500 kV line at the United States/Canadian border approximately seven-and-a-half miles west of Warroad in Roseau County, Minnesota. This line connects with a 500 kV line owned and operated by the Manitoba Hydro-Electric Board (MHEB), which extends from Dorsey, Manitoba, Canada to the United States/Canadian border. NSP proposes to increase the electricity transfer capability of this transmission facility by constructing a new 80-acre substation on the existing 500 kV line in Roseau County, Minnesota, and upgrading the existing substation at Forbes, Minnesota. The proposed Roseau substation would contain two 41.5 ohm series capacitor banks. In addition, static VAR compensators are to be installed at the existing Forbes Substation. Approximately 5 acres would be added to the 30-acre Forbes site to house the additional equipment. No new lines would enter or exit the facility. NSP proposes to place the new Roseau Substation in service in May 1993 and to complete the upgrading of the Forbes Substation in March 1994. The primary, initial purpose of these modifications is to enable NSP to import 400 megawatts of electric power from MHEB during the summer months to meet peak electrical demand in the Minneapolis-St. Paul area. It is expected that this power transfer would begin in 1993.

  1. Overview of MoronytoRainbow Line (background) in context with RyantoRainbow 100kV ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Overview of Morony-to-Rainbow Line (background) in context with Ryan-to-Rainbow 100kV Transmission Lines 1 and 2 (center and foreground) about three miles southwest of Morony Dam and Powerhouse. View to north - Morony Hydroelectric Facility, Morony-to-Rainbow 100 kV Transmission Line, West bank of the Missouri River, Great Falls, Cascade County, MT

  2. El Paso Electric Company Diablo Substation to the US-Mexico border 115kV transmission line project. Final Environmental Assessment

    SciTech Connect

    Not Available

    1992-04-01

    This Environmental Assessment documents the analysis of alternative corridors for development and operation of a proposed 115 kilovolt transmission line using private lands and transporting power to the US-Mexico international border. The project will require (1) an amendment to El Paso Electric Company`s existing export authorization to transfer power across this border, and (2) a Presidential Permit for construction of the transmission line. The project would be located in Dona Ana county in southern New Mexico, approximately five miles west of El Paso, Texas. The alternative corridors, specific locations within those corridors, and structure types are identified and analyzed in the environmental studies.

  3. Corona performance of a compact 230-kV line

    SciTech Connect

    Chartier, V.L.; Blair, D.E.; Easley, M.D.; Raczkowski, R.T.

    1995-01-01

    Permitting requirements and the acquisition of new rights-of-way for transmission facilities has in recent years become increasingly difficult for most utilities, including Puget Sound Power and Light Company. In order to maintain a high degree of reliability of service while being responsive to public concerns regarding the siting of high voltage (HV) transmission facilities, Puget Power has found it necessary to more heavily rely upon the use of compact lines in franchise corridors. Compaction does, however, precipitate increased levels of audible noise (AN) and radio and TV interference (RI and TVI) due to corona on the conductors and insulator assemblies. Puget Power relies upon the Bonneville Power Administration (BPA) Corona and Field Effects computer program to calculate AN and RI for new lines. Since there was some question of the program`s ability to accurately represent quiet 230-kV compact designs, a joint project was undertaken with BPA to verify the program`s algorithms. Long-term measurements made on an operating Puget Power 230-kV compact line confirmed the accuracy of BPA`s AN model; however, the RI measurements were much lower than predicted by the BPA and other programs. This paper also describes how the BPA computer program can be used to calculate the voltage needed to expose insulator assemblies to the correct electric field in single test setups in HV laboratories.

  4. Corona performance of a compact 230-kV line

    SciTech Connect

    Chartier, V.L.; Blair, D.E.; Easley, M.D.; Raczkowski, R.T.

    1994-12-31

    Permitting requirements and the acquisition of new rights-of-way for transmission facilities has in recent years become increasingly difficult for most utilities, including Puget Sound Power and Light Company. In order to maintain a high degree of reliability of service while being responsive to public concerns regarding the siting of high voltage (HV) transmission facilities, Puget Power has found it necessary to more heavily rely upon the use of compact lines in franchise corridors. Compaction does, however, precipitant increased levels of audible noise (AN) and radio and TV interference (RI and TVI) due to corona on the conductors and insulator assemblies. Puget Power relies upon the Bonneville Power Administration (BPA) Corona and Field Effects computer program to calculate AN and RI for new lines. Since there was some question of the program`s ability to accurately represent quiet 230-kV compact designs, a joint project was undertaken with BPA to verify the program`s algorithms. Long-term measurements made on an operating Puget Power 230-kV compact line confirmed the accuracy of BPA`s AN model; however, the RI measurements were much lower than predicted by the BPA computer and other programs. This paper also describes how the BPA computer program can be used to calculate the voltage needed to expose insulator assemblies to the correct electric field in single test setups in HV laboratories.

  5. Draft environmental impact statement for construction and operation of the proposed Bangor Hydro-Electric Company`s second 345-kV transmission tie line to New Brunswick

    SciTech Connect

    1993-10-01

    This Draft Environmental Impact Statement (DEIS) was prepared by the US Department of Energy (US DOE). The proposed action is the issuance of Presidential Permit PP-89 by DOE to Bangor Hydro-Electric Company to construct and operate a new international transmission line interconnection to New Brunswick, Canada that would consist of an 83.8 mile (US portion), 345-kilovolt (kV) alternating current transmission line from the US-Canadian border at Baileyville, Maine to an existing substation at Orrington, Maine. The principal environmental impacts of the construction and operation of the transmission line would be incremental in nature and would include the conversion of forested uplands (mostly commercial timberlands) and wetlands to right-of-way (small trees, shrubs, and herbaceous vegetation). The proposed line would also result in localized minor to moderate visual impacts and would contribute a minor incremental increase in the exposure of some individuals to electromagnetic fields. This DEIS documents the purpose and need for the proposed action, describes the proposed action and alternatives considered and provides a comparison of the proposed and alternatives routes, and provides detailed information on analyses of the environmental consequences of the proposed action and alternatives, as well as mitigative measures to minimize impacts.

  6. Proposed Amendment to Presidential Permit PP-63 and Associated Modifications to 500-kV International Transmission Line: Forbes, Minnesota to Manitoba, Canada, Northern States Power Company. Addendum to the final Environmental Assessment

    SciTech Connect

    Not Available

    1992-10-01

    This Addendum to the Final Environmental Assessment for the Proposed Amendment to Presidential Permit PP-63 and Associated Modifications to 500 kV International Transmission Line: Forbes, Minnesota to Manitoba, Canada (DOE/EA-587) addresses Northern States Power Company`s (NSP) proposed expansion of the Forbes Substation. The applicant has requested that the expansion take place on the west side of the substation, within the existing property line, instead of on the north side as originally proposed. All of the proposed construction would take place on property already owned by NSP. DOE has reviewed the environmental impacts associated with this minor modification and has determined that the conclusions reached in the environmental assessment and Finding of No Significant Impact prepared in connection with NSP`s original amendment request remain valid.

  7. 78 FR 9358 - Dairyland Power Cooperative: CapX 2020 Hampton-Rochester-La Crosse 345-kV Transmission Line Proposal

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-08

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF AGRICULTURE Rural Utilities Service Dairyland Power Cooperative: CapX 2020 Hampton-Rochester-La Crosse 345-kV... site at http://www.rurdev.usda.gov/UWP-CapX2020-Hampton-Rochester-LaCrosse.html . SUPPLEMENTARY...

  8. Impact Mitigation and Monitoring of the BPA 500 KV Garrison-Taft Transmission Line : Effects on Elk Security and Hunter Opportunity : Annual Progress Report for 1986.

    SciTech Connect

    Thompson, Michael J.; Dickson, David C.

    1987-06-01

    The objectives were: (1) to determine the effectiveness of the mitigation measures employed in the Garrison-Taft Project to minimize impacts on elk; (2) to determine the nature and magnitude of the Project impacts on elk summer-fall habitat use, distribution, use of security areas, and harvest, with emphasis on the adult male segment of the population; (3) to identify and recommend protection for important elk security areas remaining in areas adjacent to the Project; (4) to assess Project impacts on hunter opportunity and on hunters' perceptions of hunting as related to the transmission line, right-of-way, and road systems; (5) to reduce to the extent possible the net Project impacts on elk and elk hunter opportunity; and (6) to determine appropriate measures for offsetting unmitigated impacts. This involved assessing Project-caused changes along the entire route and comparing these with documented impacts on elk and elk hunting within the study areas.

  9. Series Transmission Line Transformer

    DOEpatents

    Buckles, Robert A.; Booth, Rex; Yen, Boris T.

    2004-06-29

    A series transmission line transformer is set forth which includes two or more of impedance matched sets of at least two transmissions lines such as shielded cables, connected in parallel at one end ans series at the other in a cascading fashion. The cables are wound about a magnetic core. The series transmission line transformer (STLT) which can provide for higher impedance ratios and bandwidths, which is scalable, and which is of simpler design and construction.

  10. Impact Mitigation and Monitoring of the BPA 500-kV Garrison-Taft Transmission Line : Effects on Elk Security and Hunter Opportunity, Final Report.

    SciTech Connect

    Canfield, Jodie E.

    1988-11-01

    This study was conducted by the Montana Department of Fish, Wildlife and Parks from 1984--1988 to assess the impacts of the Garrison-Taft segment of a 500-kV powerline on elk summer-fall habitat. Construction of the powerline began in 1983, and the powerline was energized in 1985. The Garrison-Taft powerline corridor crossed 251 km of mountainous terrain in western Montana; about 465 km of new roads were constructed to provide permanent access to the powerline towers. The objectives of the study were: (1) to monitor the effectiveness of mitigation measures, including timing restrictions on construction activities and road closures on newly-built access roads, and (2) to determine if opening previously-unroaded elk security habitats to hunters by powerline access roads affected elk habitat use, distribution, use of security areas, or elk harvest. In addition, both the potential for accelerated timber harvest in areas crossed by the powerline that would not have otherwise been logged because of marginal economics and lack of haul roads and the potential effect of powerline flashovers on future prescribed burning of elk winter-ranges were evaluated. 83 refs., 88 figs., 15 tabs.

  11. Proposed Four Corners-Ambrosia-Pajarito 500 kV transmission project. Draft environmental statement

    SciTech Connect

    Not Available

    1980-01-01

    The Public Service Company of New Mexico proposes to construct and operate a 500 kV alternating current (ac) transmission line in the northwestern portion of New Mexico. The proposed line will extend from the Four Corners Power Plant to Ambrosia Station to a proposed Pajarito Station west of Albuquerque, NM. The proposed line will be approximately 173 miles in length. Construction of the 500 kV transmission line will adversely impact soils, vegetation, visual resources, and possibly in an indirect manner, the cultural resources in the area. These adverse impacts may be made minimal by the practice of erosion protection measures, revegetation, and a sound cultural resource management plan. There will be no appreciable impacts, adverse or otherwise in regard to surface or subsurface water by the construction or operation of the proposed transmission line. No adverse effects may be anticipated in regard to communities or social services. Economic impacts in the area will be short-term and should prove beneficial for the duration of the project. Construction and operation of this line will be beneficial in providing needed additional bulk transmission capacity between the Four Corners Plant and Albuquerque and bulk transmission support to the local western New Mexico area.

  12. Proposed Four Corners-Ambrosia-Pajarito 500 kV transmission project. Final environmental statement

    SciTech Connect

    Not Available

    1980-01-01

    The Public Service Company of New Mexico proposes to construct and operate a 500 kV alternating current (AC) transmission line in the northwestern portion of New Mexico. The proposed line will extend from the Four Corners Power Plant to Ambrosia Station to a proposed Pajarito Station west of Albuquerque, NM. The proposed line will be approximately 173 miles in length. Construction of the 500 kV transmission line will adversely impact soils, vegetation, visual resources, and possibly in an indirect manner, the cultural resources in the area. The adverse impacts may be made minimal by the practice of erosion protection measures, revegetation, and a sound cultural resource management plan. There will be no appreciable impacts, adverse or otherwise in regard to surface or subsurface water by the construction or operation of the proposed transmission line. No adverse effects may be anticipated in regard to communities or social services. Economic impacts in the area will be short-term and should prove beneficial for the duration of the project. Construction and operation of this line will be beneficial in providing needed additional bulk transmission capacity between the Four Corners Plant and Albuquerque and bulk transmission support to the local western New Mexico area.

  13. Transmission Line Security Monitor

    ScienceCinema

    None

    2016-07-12

    The Transmission Line Security Monitor is a multi-sensor monitor that mounts directly on high-voltage transmission lines to detect, characterize and communicate terrorist activity, human tampering and threatening conditions around support towers. For more information about INL's critical infrastructure protection research, visit http://www.facebook.com/idahonationallaboratory.

  14. Transmission Line Security Monitor

    SciTech Connect

    2011-01-01

    The Transmission Line Security Monitor is a multi-sensor monitor that mounts directly on high-voltage transmission lines to detect, characterize and communicate terrorist activity, human tampering and threatening conditions around support towers. For more information about INL's critical infrastructure protection research, visit http://www.facebook.com/idahonationallaboratory.

  15. The Anomaly Power Transmission and Analysis at a 500kV GIS Substation

    NASA Astrophysics Data System (ADS)

    Qi, Geqing; Wu, Gang; Qi, Zhuang; Meng, Fanlong; Jin, Daxin; Zhang, Wei; Zhang, Nan; Wang, Lulu

    2017-07-01

    In view of the extension which steps up from 220kV to 500kV at the switching station, induced the flashover of insulation spacer in gas chamber from 500kV line side, the voltage fault of 500kV bus, the discharge of junction which between oil-gas casing of 500kV main transformer from 220kV bus side and GIS branch bus, due to improper installation. The paper analyzes connection diagram, graph of fault recorder and repair with disassembly point for point. It also suggests the recommendations for improvement, to avoid the appearance.

  16. Transmission line capital costs

    SciTech Connect

    Hughes, K.R.; Brown, D.R.

    1995-05-01

    The displacement or deferral of conventional AC transmission line installation is a key benefit associated with several technologies being developed with the support of the U.S. Department of Energy`s Office of Energy Management (OEM). Previous benefits assessments conducted within OEM have been based on significantly different assumptions for the average cost per mile of AC transmission line. In response to this uncertainty, an investigation of transmission line capital cost data was initiated. The objective of this study was to develop a database for preparing preliminary estimates of transmission line costs. An extensive search of potential data sources identified databases maintained by the Bonneville Power Administration (BPA) and the Western Area Power Administration (WAPA) as superior sources of transmission line cost data. The BPA and WAPA data were adjusted to a common basis and combined together. The composite database covers voltage levels from 13.8 to 765 W, with cost estimates for a given voltage level varying depending on conductor size, tower material type, tower frame type, and number of circuits. Reported transmission line costs vary significantly, even for a given voltage level. This can usually be explained by variation in the design factors noted above and variation in environmental and land (right-of-way) costs, which are extremely site-specific. Cost estimates prepared from the composite database were compared to cost data collected by the Federal Energy Regulatory Commission (FERC) for investor-owned utilities from across the United States. The comparison was hampered because the only design specifications included with the FERC data were voltage level and line length. Working within this limitation, the FERC data were not found to differ significantly from the composite database. Therefore, the composite database was judged to be a reasonable proxy for estimating national average costs.

  17. Environmental studies for a 1100-kV power line in Oregon. A special report

    SciTech Connect

    Rogers, L.; Hinds, R.

    1983-01-01

    In the first research project to monitor the effects of 1100-kV transmission on a natural ecosystem, researchers at Battelle, Pacific Northwest Laboratories have studied responses of wildlife, native plants, honeybees, and agricultural crops and cattle. No adverse effects were detected on wildlife, crops or cattle. Effects were observed on trees growing within the defined right of way and on honeybee colonies placed beneath the line.

  18. Development of extruded dielectric underground transmission cables rated 138 kV, 230 kV, and 345 kV. Final report

    SciTech Connect

    Bahder, G.; Bopp, L.A.; Eager, G.S.; Katz, C.; Knott, A.; Schmidt, G.A.

    1982-02-01

    This report covers the continuation of the work to develop technology to manufacture chemically crosslinked polyethylene insulated power cables in the ac voltage range of 138 kV to 345 kV having insulation thicknesses approximately equal to that of oil impregnated paper insulated cables. It also incorporates the development of field molded splices and terminations for new high voltage stress 138 kV cables. After reviewing the main equipment elements, incorporated in the pilot extrusion line, the special features of this system are noted and a step-by-step description of the cable extrusion process is given. Optimization of the process and introduction of modifications in the equipment culminated with the production of 138 kV cables. Results of laboratory tests to demonstrate the high quality of the cables are given. The development of molded splices and molded stress control cones was initiated with the work on model cables and followed by the making of splices and terminations on 138 kV cables. The molded components are made with the same purified insulating compound as used in the manufacture of the cables. Both the molded splices and the molded stress control cones have been fully tested in the laboratory. Following the completion of the development of the 138 kV cable a high stress 230 kV crosslinked polyethylene cable was developed and optimized. A full evaluation program similar to the one utilized on the 138 kV cable was carried out. Subsequently, work to develop a 345 kV high voltage stress cable, having insulation thickness of 1.02'' was undertaken. 345 kV cables were successfully manufactured and tested. However, additional work is required to further optimize the quality of this cable.

  19. Garrison-Taft 500 KV Transmission Project : Phase II Hunter Survey Final Report.

    SciTech Connect

    Allen, Steward D.

    1989-07-01

    This report presents the results of the Phase 2 survey of hunters conducted to assess the impacts of Bonneville Power Administration's 500-kV transmission line on elk hunting opportunities in western Montana. The survey is the second in a series of three; a baseline study was conducted in 1983 before the line was constructed and a mail survey will be conducted in 1987. The three surveys form the social component of the Elk Monitoring and Mitigation Project being conducted by several state and federal agencies. A report prepared by the Montana Department of Fish, Wildlife and Parks contains background information on the transmission line and entire monitoring effort, a description of the two primary study areas, and progress on the biological component of the study. 2 refs., 4 tabs.

  20. Automatic transmission line monitor

    NASA Technical Reports Server (NTRS)

    Parsons, W. E.; Richards, L. O.

    1971-01-01

    Monitor improves complex network reliability in computer data links and command transmission lines. System evaluates circuit performance against preselected criteria, identifies and stores data indicating out-of-tolerance conditions, conducts closed loop testing, and provides for operation under command of digital computer that determines restoration priorities.

  1. Printed circuit dispersive transmission line

    DOEpatents

    Ikezi, Hiroyuki; Lin-Liu, Yuh-Ren; DeGrassie, John S.

    1991-01-01

    A printed circuit dispersive transmission line structure is disclosed comprising an insulator, a ground plane formed on one surface of the insulator, a first transmission line formed on a second surface of the insulator, and a second transmission line also formed on the second surface of the insulator and of longer length than the first transmission line and periodically intersecting the first transmission line. In a preferred embodiment, the transmission line structure exhibits highly dispersive characteristics by designing the length of one of the transmission line between two adjacent periodic intersections to be longer than the other.

  2. Printed circuit dispersive transmission line

    DOEpatents

    Ikezi, H.; Lin-Liu, Y.R.; DeGrassie, J.S.

    1991-08-27

    A printed circuit dispersive transmission line structure is disclosed comprising an insulator, a ground plane formed on one surface of the insulator, a first transmission line formed on a second surface of the insulator, and a second transmission line also formed on the second surface of the insulator and of longer length than the first transmission line and periodically intersecting the first transmission line. In a preferred embodiment, the transmission line structure exhibits highly dispersive characteristics by designing the length of one of the transmission line between two adjacent periodic intersections to be longer than the other. 5 figures.

  3. Motor dysfunction and altered synaptic transmission at the parallel fiber-Purkinje cell synapse in mice lacking potassium channels Kv3.1 and Kv3.3.

    PubMed

    Matsukawa, Hiroshi; Wolf, Alexander M; Matsushita, Shinichi; Joho, Rolf H; Knöpfel, Thomas

    2003-08-20

    Micelacking both Kv3.1 and both Kv3.3 K+ channel alleles display severe motor deficits such as tremor, myoclonus, and ataxic gait. Micelacking one to three alleles at the Kv3.1 and Kv3.3 loci exhibit in an allele dose-dependent manner a modest degree of ataxia. Cerebellar granule cells coexpress Kv3.1 and Kv3.3 K+ channels and are therefore candidate neurons that might be involved in these behavioral deficits. Hence, we investigated the synaptic mechanisms of transmission in the parallel fiber-Purkinje cell system. Action potentials of parallel fibers were broader in mice lacking both Kv3.1 and both Kv3.3 alleles and in mice lacking both Kv3.1 and a single Kv3.3 allele compared with those of wild-type mice. The transmission of high-frequency trains of action potentials was only impaired at 200 Hz but not at 100 Hz in mice lacking both Kv3.1 and Kv3.3 genes. However, paired-pulse facilitation (PPF) at parallel fiber-Purkinje cell synapses was dramatically reduced in a gene dose-dependent manner in mice lacking Kv3.1 or Kv3.3 alleles. Normal PPF could be restored by reducing the extracellular Ca2+ concentration indicating that increased activity-dependent presynaptic Ca2+ influx, at least in part caused the altered PPF in mutant mice. Induction of metabotropic glutamate receptor-mediated EPSCs was facilitated, whereas longterm depression was not impaired but rather facilitated in Kv3.1/Kv3.3 double-knockout mice. These results demonstrate the importance of Kv3 potassium channels in regulating the dynamics of synaptic transmission at the parallel fiber-Purkinje cell synapse and suggest a correlation between short-term plasticity at the parallel fiber-Purkinje cell synapse and motor performance.

  4. Drill string transmission line

    DOEpatents

    Hall, David R.; Hall, Jr., H. Tracy; Pixton, David S.; Bradford, Kline; Fox, Joe

    2006-03-28

    A transmission line assembly for transmitting information along a downhole tool comprising a pin end, a box end, and a central bore traveling between the pin end and the box end, is disclosed in one embodiment of the invention as including a protective conduit. A transmission line is routed through the protective conduit. The protective conduit is routed through the central bore and the ends of the protective conduit are routed through channels formed in the pin end and box end of the downhole tool. The protective conduit is elastically forced into a spiral or other non-linear path along the interior surface of the central bore by compressing the protective conduit to a length within the downhole tool shorter than the protective conduit.

  5. New Waddell-Westwing 230-kV transmission project, Maricopa County, Arizona: Environmental assessment

    SciTech Connect

    Not Available

    1988-10-01

    The Western Area Power Administration (Western) proposes to construct a new 230 kilovolt (kV) transmission line in Maricopa County, Arizona, that would extend from the New Waddell Dam on the Agua Fria River, to the Westwing Substation, about 10.5 miles southwest of the dam. The project area is roughly 45 miles northwest of the Phoenix metropolitan area. Western will complete the National Environmental Policy Act of 1969 (NEPA) process for the line. A final environmental impact statement (EIS) was prepared by BuRec to describe the environmental impacts associated with alternatives for the construction and operation of the Regulatory Storage Division of the Central Arizona Project (CAP). The EIS was supported by 23 technical reports that covered planning, design, public involvement, social and environmental impact assessment, economics, and hydrological analysis. Since the proposed transmission system differs only slightly from that described in the EIS, Western incorporates by reference the EIS and its 23 supporting technical reports into this environmental assessment (EA). In August 1985, BuRec completed an EA on modifications to the New Waddell Dam Project design plans and issued a FONSI on these modifications; the EA did not cover the transmission line. The purpose of this EA is to document the potential environmental effects of the proposed construction of the transmission line and switchyards in order to determine if an EIS is needed or if a finding of no significant impact (FONSI) is indicated. 28 refs., 5 figs., 1 tab.

  6. A Quantitative Transmission Line Experiment

    ERIC Educational Resources Information Center

    Johnston, D. C.; Silbernagel, B. G.

    1969-01-01

    Describes modifications of a commercially available strip-type transmission line, which makes possible reproducible measurements of standing waves on the line. Experimental data yield values for the characteristic impedance, phase velocity and line wavelength of radiation in the transmission line, and the dielectric constant of material in the…

  7. A Quantitative Transmission Line Experiment

    ERIC Educational Resources Information Center

    Johnston, D. C.; Silbernagel, B. G.

    1969-01-01

    Describes modifications of a commercially available strip-type transmission line, which makes possible reproducible measurements of standing waves on the line. Experimental data yield values for the characteristic impedance, phase velocity and line wavelength of radiation in the transmission line, and the dielectric constant of material in the…

  8. Atlas Transmission Line/Transition Design and Fabrication Status

    DTIC Science & Technology

    1999-06-01

    completed for this new generation pulsed-power machine consisting of an azimuthal array of 24, 240-kV Marx modules and transmission lines supplying current...to the center transition section. The cable header interface to the Marx module provides a mechanism to remove the Marx module for maintenance... Marx in the event of a pre-fire condition. The aluminum tri-plate is a low-inductance transmission line that carries radial current flow from the Marx

  9. Dielectric Nonlinear Transmission Line (Postprint)

    DTIC Science & Technology

    2011-12-01

    Technical Paper 3. DATES COVERED (From - To) 2011 4. TITLE AND SUBTITLE Dielectric Nonlinear Transmission Line (POSTPRINT) 5a. CONTRACT NUMBER...14. ABSTRACT A parallel plate nonlinear transmission line (NLTL) was constructed. Periodic loading of nonlinear dielectric slabs provides the...846-9101 Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. 239.18 Dielectric Nonlinear Transmission Line David M. French, Brad W. Hoff

  10. EC Transmission Line Materials

    SciTech Connect

    Bigelow, Tim S

    2012-05-01

    The purpose of this document is to identify materials acceptable for use in the US ITER Project Office (USIPO)-supplied components for the ITER Electron cyclotron Heating and Current Drive (ECH&CD) transmission lines (TL), PBS-52. The source of material property information for design analysis shall be either the applicable structural code or the ITER Material Properties Handbook. In the case of conflict, the ITER Material Properties Handbook shall take precedence. Materials selection, and use, shall follow the guidelines established in the Materials Assessment Report (MAR). Materials exposed to vacuum shall conform to the ITER Vacuum Handbook. [Ref. 2] Commercial materials shall conform to the applicable standard (e.g., ASTM, JIS, DIN) for the definition of their grade, physical, chemical and electrical properties and related testing. All materials for which a suitable certification from the supplier is not available shall be tested to determine the relevant properties, as part of the procurement. A complete traceability of all the materials including welding materials shall be provided. Halogenated materials (example: insulating materials) shall be forbidden in areas served by the detritiation systems. Exceptions must be approved by the Tritium System and Safety Section Responsible Officers.

  11. Investigation of a stripline transmission line structure for gyromagnetic nonlinear transmission line high power microwave sources.

    PubMed

    Reale, D V; Parson, J M; Neuber, A A; Dickens, J C; Mankowski, J J

    2016-03-01

    A stripline gyromagnetic nonlinear transmission line (NLTL) was constructed out of yttrium iron garnet ferrite and tested at charge voltages of 35 kV-55 kV with bias fields ranging from 10 kA/m to 20 kA/m. Typically, high power gyromagnetic NLTLs are constructed in a coaxial geometry. While this approach has many advantages, including a uniform transverse electromagnetic (TEM) mode, simple interconnection between components, and the ability to use oil or pressurized gas as an insulator, the coaxial implementation suffers from complexity of construction, especially when using a solid insulator. By moving to a simpler transmission line geometry, NLTLs can be constructed more easily and arrayed on a single substrate. This work represents a first step in exploring the suitability of various transmission line structures, such as microstrips and coplanar waveguides. The resulting high power microwave (HPM) source operates in ultra high frequency (UHF) band with an average bandwidth of 40.1% and peak rf power from 2 MW to 12.7 MW.

  12. Investigation of a stripline transmission line structure for gyromagnetic nonlinear transmission line high power microwave sources

    NASA Astrophysics Data System (ADS)

    Reale, D. V.; Parson, J. M.; Neuber, A. A.; Dickens, J. C.; Mankowski, J. J.

    2016-03-01

    A stripline gyromagnetic nonlinear transmission line (NLTL) was constructed out of yttrium iron garnet ferrite and tested at charge voltages of 35 kV-55 kV with bias fields ranging from 10 kA/m to 20 kA/m. Typically, high power gyromagnetic NLTLs are constructed in a coaxial geometry. While this approach has many advantages, including a uniform transverse electromagnetic (TEM) mode, simple interconnection between components, and the ability to use oil or pressurized gas as an insulator, the coaxial implementation suffers from complexity of construction, especially when using a solid insulator. By moving to a simpler transmission line geometry, NLTLs can be constructed more easily and arrayed on a single substrate. This work represents a first step in exploring the suitability of various transmission line structures, such as microstrips and coplanar waveguides. The resulting high power microwave (HPM) source operates in ultra high frequency (UHF) band with an average bandwidth of 40.1% and peak rf power from 2 MW to 12.7 MW.

  13. Application of lightning arrester on transmission lines

    NASA Astrophysics Data System (ADS)

    Matsubara, K.

    1990-05-01

    A lightning arrester on transmission lines is expected to reduce lightning incidents; however, the problems of the application guide to be established such as the method of application, the treating capacity for lightning energy, and the coordination to an arc horn remain as they are. The method of application for a lightning arrester on transmission lines and its effect are examined from the viewpoint of the generating incident on transmission lines by lightning and the operating viewpoint of a lightning arrester for a 77kV system. The double circuit setup of an arrester is the best method to reduce the lightning incidents and the single circuit setup can reduce the incident rate by 40 percent preventing the flashover of the circuit on which the arrester is not set up. For installing an arrester on a short section, the flashover point can transfer to the next steel tower where the arrester is not set up, only when lightning strikes the last steel tower. Inflowing current into an arrester from a direct lightning strike is considerably large and the energy at that time becomes large but this energy can be reduced by the operation of the arrester set up on another steel tower.

  14. Electrical transmission line diametrical retainer

    DOEpatents

    Hall, David R.; Hall, Jr., H. Tracy; Pixton, David; Dahlgren, Scott; Sneddon, Cameron; Briscoe, Michael; Fox, Joe

    2004-12-14

    The invention is a mechanism for retaining an electrical transmission line. In one embodiment of the invention it is a system for retaining an electrical transmission line within down hole components. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmission line to with stand the tension and compression of drill pipe during routine drilling cycles.

  15. Increasing the reliability of the shutdown of 500 - 750-kV overhead lines equipped with shunt reactors in an unsuccessful three-phase automatic repeated closure cycle

    SciTech Connect

    Kuz'micheva, K. I.; Merzlyakov, A. S.; Fokin, G. G.

    2013-05-15

    The reasons for circuit-breaker failures during repeated disconnection of 500 - 750 kV overhead lines with shunt reactors in a cycle of unsuccessful three-phase automatic reconnection (TARC) are analyzed. Recommendations are made for increasing the operating reliability of power transmission lines with shunt reactors when there is unsuccessful reconnection.

  16. Garrison-Taft 500 KV Transmission Project : Phase III Hunter Survey, Final Report.

    SciTech Connect

    Allen, Stewart D.

    1989-07-01

    This report presents the results of the Phase 3 survey of hunters conducted to assess the impacts of Bonneville Power Administration's 500-kV transmission line on elk hunting opportunities in western Montana. This survey is the final in a series of three (Allen, 1983; 1988). These three surveys are the social component of the Elk Monitoring and Mitigation Project being conducted by several state and federal agencies. A report prepared by the Montana Department of Fish, Wildlife and Parks contains a description of the entire monitoring effort, a description of the two study areas, and progress on the biological component of the study (Canfield, 1988). The primary concern is that the line and associated access roads could decrease hunters' perceptions of the quality of the setting, potentially leading to less satisfaction. Hunters could continue to hunt in the areas but with less enjoyment, they could discontinue hunting in the area, or they could continue to use the area, but differently than before. The study also was designed to identify positive effects of the line. The Phase 3 hunter survey asked a sample of hunters interviewed at check stations during Phase 2 about their use of the DeBorgia (western) study area and the Harvey Creek-Eightmile (eastern) study area during the Fall, 1987 hunting season. Before presenting the methods and results, it may be helpful to summarize the findings from the Phase 1 and 2 hunter surveys, to provide a context for interpreting Phase 3 data. 5 refs., 11 tabs.

  17. Development of a thyristor valve for next generation 500kV HVDC transmission systems

    SciTech Connect

    Hasegawa, T.; Yamaji, K.; Irokawa, H.; Shirahama, H.; Tanaka, C.; Akabane, K.

    1996-10-01

    A high voltage thyristor valve is the basic component of an HVDC transmission system. Development of a 500kV valve for next generation HVDC transmission systems is described. First, the power loss of the valve is analyzed to decide a reasonable wafer size for the light triggered thyristor. From these results, a six inch diameter wafer size is selected. The light triggered thyristor, with ratings of 8kV and 3.5kA, is developed using the six inch wafer. The designing of the valve employing the thyristor and test results with the prototype valve prove that a 500kV valve can be realized by the design method.

  18. Power transmission line monitoring system

    SciTech Connect

    Seppa, T.O.

    1993-08-17

    A method for monitoring the sag of an overhead power transmission line comprising the steps of: measuring the tension of the power line; producing an electrical signal representative of the tension measurement; processing said electrical signal in accordance with a predetermined tension-sag relationship to produce a second signal which is a function of sag of the power line; transmitting said second electrical signal to a distant location in a predetermined transmission mode; receiving the second signal at the distant location whereby current in the power line is adjusted in accordance with the received second signal.

  19. A tunable magnetically insulated transmission line oscillator

    NASA Astrophysics Data System (ADS)

    Fan, Yu-Wei; Wang, Xiao-Yu; He, Liang; Zhong, Hui-Huang; Zhang, Jian-De

    2015-03-01

    A tunable magnetically insulated transmission line oscillator (MILO) is put forward and simulated. When the MILO is driven by a 430 kV, 40.6 kA electron beam, high-power microwave is generated with a peak output power of 3.0 GW and frequency of 1.51 GHz, and the relevant power conversion efficiency is 17.2%. The 3-dB tunable frequency range (the relative output power is above half of the peak output power) is 2.25-0.825 GHz when the outer radius of the slow-wave structure (SWS) vanes ranges from 77 mm to 155 mm, and the 3-dB tuning bandwidth is 92%, which is sufficient for the aim of large-scale tuning and high power output. Project supported by the National Natural Science Foundation of China (Grant No. 11075210) and the Special Financial Grant from the China Postdoctoral Science Foundation (Grant No. 201104761).

  20. Harmonic resonance on parallel high voltage transmission lines

    SciTech Connect

    Harries, J.R.; Randall, J.L.

    1997-01-01

    The Bonneville Power Administration (BPA) has received complaints of telephone interference over a wide area of northwestern Washington State for several years. However, until 1995 investigations had proved inconclusive as either the source of the harmonics or the operating conditions changed whenever investigators arrived. The 2,100 Hz interference had been noticed at several optically isolated telephone exchanges. The area of complaint corresponded to electric service areas near the transmission line corridors of the BPA Custer-Monroe 500-kV lines. High 2,100 Hz field strength was measured near the 500-kV lines and also under lower voltage lines served from stations along the transmission line corridor. Tests and studies made with the Alternative Transients Program version of the Electromagnetic Transients Program (EMTP) were able to define the phenomena and isolate the source. Harmonic resonance has been observed, measured and modeled on parallel 500-kV lines that are about one wavelength at 2,100 Hz, the 35th harmonic. A seemingly small harmonic injection at one location on the system causes significant problems some distance away such as telephone interference.

  1. Transmission lines emulating moving media

    NASA Astrophysics Data System (ADS)

    Vehmas, J.; Hrabar, S.; Tretyakov, S.

    2014-09-01

    In this paper, we show how the electromagnetic phenomena in moving magnetodielectric media can be emulated using artificial composite structures at rest. In particular, we introduce nonreciprocal periodically loaded transmission lines, which support waves obeying the same rules as plane electromagnetic waves in moving media. Because the actual physical structure is at rest, in these transmission lines there are no fundamental limitations on the velocity values, which may take values larger than the speed of light or even complex values (considering complex amplitudes in the time-harmonic regime). An example circuit of a unit cell of a ‘moving’ transmission line is presented and analyzed both numerically and experimentally. The special case of a composite right-/left- handed host line is also studied numerically. Besides the fundamental interest, the study is relevant for potential applications in realizing engineered materials for various transformations of electromagnetic fields.

  2. Electrical and mechanical design criteria for EHV and UHV: overhead transmission lines

    SciTech Connect

    Not Available

    1980-06-01

    The results are presented of a program devoted to the selection of electrical and mechanical design criteria and parameters for overhead power transmission lines for ac systems rated at from 345 to 1100 kV and for dc systems rated at from 600 to 1200 kV. Information is included on the environmental effects, i.e., audible noise and electric fields, of the lines, mechanical and economic requirements, safety, failures, grounding, and lightning protection. (LCL)

  3. Hazard analysis for magnetic induction from electric transmission lines

    NASA Astrophysics Data System (ADS)

    Taylor, R. J.

    1983-06-01

    The potential hazard of magnetic induction from electric transmission lines was investigated. A literature search was accomplished, measurements were made and compared with the theories found in the literature and a new approach was developed for estimating the hazardous potential of magnetically induced voltage in fences which could be grasped by barefoot children under wet conditions. Conditions under which representative transmission lines could induce such voltage were explored. For example, a standard three-phase horizontal 500 KV transmission line carrying 1000 A was estimated to induce 10.5 V in a 900 M fence 30 M from the center of the line. It was also found that third harmonic currents can magnetically induce significant voltages compared to those induced by 60 HZ currents umder some circumstances.

  4. Atlas Transmission Line Breakdown Analysis

    DTIC Science & Technology

    1999-06-01

    The Atlas facility will use 24 radially converging, vertically oriented and tapered, oil insulated, triplate transmission lines between the Marx ...taper from a height of 1.75 m at the Marx end to 0.32 m at the output end. The aluminum conductors, held together by 20 insulating spacers, are

  5. Investigation of a stripline transmission line structure for gyromagnetic nonlinear transmission line high power microwave sources

    SciTech Connect

    Reale, D. V. Parson, J. M.; Neuber, A. A.; Dickens, J. C.; Mankowski, J. J.

    2016-03-15

    A stripline gyromagnetic nonlinear transmission line (NLTL) was constructed out of yttrium iron garnet ferrite and tested at charge voltages of 35 kV–55 kV with bias fields ranging from 10 kA/m to 20 kA/m. Typically, high power gyromagnetic NLTLs are constructed in a coaxial geometry. While this approach has many advantages, including a uniform transverse electromagnetic (TEM) mode, simple interconnection between components, and the ability to use oil or pressurized gas as an insulator, the coaxial implementation suffers from complexity of construction, especially when using a solid insulator. By moving to a simpler transmission line geometry, NLTLs can be constructed more easily and arrayed on a single substrate. This work represents a first step in exploring the suitability of various transmission line structures, such as microstrips and coplanar waveguides. The resulting high power microwave (HPM) source operates in ultra high frequency (UHF) band with an average bandwidth of 40.1% and peak rf power from 2 MW to 12.7 MW.

  6. Pulse shaping with transmission lines

    DOEpatents

    Wilcox, R.B.

    1985-08-15

    A method and apparatus for forming shaped voltage pulses uses passive reflection from a transmission line with nonuniform impedance. The impedance of the reflecting line varies with length in accordance with the desired pulse shape. A high voltage input pulse is transmitted to the reflecting line. A reflected pulse is produced having the desired shape and is transmitted by pulse removal means to a load. Light activated photoconductive switches made of silicon can be utilized. The pulse shaper can be used to drive a Pockels cell to produce shaped optical pulses.

  7. Pulse shaping with transmission lines

    DOEpatents

    Wilcox, Russell B.

    1987-01-01

    A method and apparatus for forming shaped voltage pulses uses passive reflection from a transmission line with nonuniform impedance. The impedance of the reflecting line varies with length in accordance with the desired pulse shape. A high voltage input pulse is transmitted to the reflecting line. A reflected pulse is produced having the desired shape and is transmitted by pulse removal means to a load. Light activated photoconductive switches made of silicon can be utilized. The pulse shaper can be used to drive a Pockels cell to produce shaped optical pulses.

  8. Electrical transmission lines in Montana: Mitigation of impacts to soil and biological sources

    SciTech Connect

    McCollough, S.A.; Ring, T.W.

    1990-12-31

    In Montana, the routing and construction of large electrical transmission lines are regulated by the Montana Major Facility Siting Act. Under this act, impacts to resources are minimized through avoidance by routing, where possible, and by mitigating remaining impacts. Land disturbed by the construction of transmission lines considered in this paper ranges from 1681 acres for a 500-kV line across 156 miles of mountainous terrain to 11 acres for a 100-kV line across 27 miles of nearly level terrain. Line access accounts for most of the disturbance, especially when graded roads are built in mountainous terrain. Land disturbed by transmission line construction is susceptible to soil erosion and weed infestation. These problems are addressed through revegetation, erosion control, and herbicide application. Transmission lines can displace wildlife from critical habitats by disruptive construction activities or by improving human access to previously secure range. Wildlife impacts can be reduced by restricting construction periods and gating roads.

  9. Coiled transmission line pulse generators

    DOEpatents

    McDonald, Kenneth Fox

    2010-11-09

    Methods and apparatus are provided for fabricating and constructing solid dielectric "Coiled Transmission Line" pulse generators in radial or axial coiled geometries. The pour and cure fabrication process enables a wide variety of geometries and form factors. The volume between the conductors is filled with liquid blends of monomers, polymers, oligomers, and/or cross-linkers and dielectric powders; and then cured to form high field strength and high dielectric constant solid dielectric transmission lines that intrinsically produce ideal rectangular high voltage pulses when charged and switched into matched impedance loads. Voltage levels may be increased by Marx and/or Blumlein principles incorporating spark gap or, preferentially, solid state switches (such as optically triggered thyristors) which produce reliable, high repetition rate operation. Moreover, these Marxed pulse generators can be DC charged and do not require additional pulse forming circuitry, pulse forming lines, transformers, or an a high voltage spark gap output switch. The apparatus accommodates a wide range of voltages, impedances, pulse durations, pulse repetition rates, and duty cycles. The resulting mobile or flight platform friendly cylindrical geometric configuration is much more compact, light-weight, and robust than conventional linear geometries, or pulse generators constructed from conventional components. Installing additional circuitry may accommodate optional pulse shape improvements. The Coiled Transmission Lines can also be connected in parallel to decrease the impedance, or in series to increase the pulse length.

  10. Application of an expert system to decisions on countermeasures against snow accretion on transmission lines

    SciTech Connect

    Nara, K.; Yamashiro, S.; Yanaura, Y.

    1988-08-01

    An expert system is discussed which assists in deciding the deicing countermeasures against snow accretion on 187KV and 66KV transmission lines. The distinctive features of the system are the application of an expert system to a new field, the completely hierarchical design of the whole system and ranking by messages instead of by a certainty factor. The system has been developed as a prototype using micro-PROLOG and is under trial use in real power system operations.

  11. Research on electric field distribution of UHVDC transmission lines and body surface during live working

    NASA Astrophysics Data System (ADS)

    Jiang, Chilong; Zou, Dehua; Li, Jinliang; Zhang, Zhanlong; Mei, Daojun

    2017-09-01

    Electric field distortion emerges around personnel working on live Ultra High Voltage Direct Current UHVDC transmission lines, especially when they move from ground-potential to equipotential positions. Unreliable protection threatens the safety of both workers and transmission lines. The current study investigates the electric field distribution of body surface during live working under transmission lines. To provide safety advice, live working person and tower models were established. The body surface field was calculated in different positions under ±800 kV transmission lines, and the distribution of the electric field was summarized.

  12. HTS DC Transmission Line for Megalopolis Grid Development

    NASA Astrophysics Data System (ADS)

    Kopylov, S.; Sytnikov, V.; Bemert, S.; Ivanov, Yu; Krivetskiy, I.; Romashov, M.; Shakaryan, Yu; Keilin, V.; Shikov, A.; Patrikeev, V.; Lobyntsev, V.; Shcherbakov, V.

    2014-05-01

    Using of HTS AC and DC cables in electric power grids allows increasing of the transferred power, losses diminishing, decreasing of exclusion zone areas, the enhancement of the environmental conditions and fire/explosion safety of electric power systems. However, the use of DC superconducting cable lines together with converters brings additional advantages as reduction of losses in cables and suitable lowering of refrigerating plant capacity, as well as the realization of the function of short-circuit currents limitation by means of the appropriate setting of converter equipment. Russian Federal Grid Company and its R&D Center started the construction of the DC HTS power transmission line which includes the cable itself, cryogenic equipment, AC/DC converters, terminals and cable coupling boxes. This line will connect two substations in Saint-Petersburg - 330 kV "Centralnaya" and 220 kV "RP-9". The length of this HTS transmission line will be about 2500 meters. Nowadays are developed all the elements of the line and technologies of the cable manufacturing. Two HTS cable samples, each 30 m length, have been made. This paper describes the results of cables tests.

  13. 29 CFR 1926.1409 - Power line safety (over 350 kV).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 8 2012-07-01 2012-07-01 false Power line safety (over 350 kV). 1926.1409 Section 1926.1409 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Cranes and Derricks in...

  14. 29 CFR 1926.1409 - Power line safety (over 350 kV).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 8 2013-07-01 2013-07-01 false Power line safety (over 350 kV). 1926.1409 Section 1926.1409 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Cranes and Derricks in...

  15. 29 CFR 1926.1409 - Power line safety (over 350 kV).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 8 2011-07-01 2011-07-01 false Power line safety (over 350 kV). 1926.1409 Section 1926.1409 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Cranes and Derricks in...

  16. 29 CFR 1926.1409 - Power line safety (over 350 kV).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 8 2014-07-01 2014-07-01 false Power line safety (over 350 kV). 1926.1409 Section 1926.1409 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Cranes and Derricks in...

  17. Three-Phase Fault Currents Evaluation for Nigerian 28-Bus 330kv Transmission System

    NASA Astrophysics Data System (ADS)

    Adepoju, Gafari A.; Tijani, Muhammed A.; Sanusi, Mufutau A.; Olatunji, Dauda O.

    2012-03-01

    Fault studies are important power system analysis for stable and economical operations of power systems. Faults are categorised as symmetrical and unsymmetrical. In this paper, three-phase symmetrical fault is simulated using the Nigerian 28-Bus, 330kV Transmission Grid. Two different MatLab based programmes were developed; one program was for Load Flow Studies which determines prefault conditions for the power system based on Newton-Raphson method. The other program determines fault current magnitudes for threephase short-circuit on the power system. The information gained from the fault studies can be used for proper relay selections, settings, performances and coordination.

  18. Superconducting transmission line particle detector

    DOEpatents

    Gray, Kenneth E.

    1989-01-01

    A microvertex particle detector for use in a high energy physic collider including a plurality of parallel superconducting thin film strips separated from a superconducting ground plane by an insulating layer to form a plurality of superconducting waveguides. The microvertex particle detector indicates passage of a charged subatomic particle by measuring a voltage pulse measured across a superconducting waveguide caused by the transition of the superconducting thin film strip from a superconducting to a non-superconducting state in response to the passage of a charged particle. A plurality of superconducting thin film strips in two orthogonal planes plus the slow electromagnetic wave propogating in a superconducting transmission line are used to resolve N.sup.2 ambiguity of charged particle events.

  19. Magnetically insulated transmission line oscillator

    DOEpatents

    Bacon, Larry D.; Ballard, William P.; Clark, M. Collins; Marder, Barry M.

    1988-01-01

    A magnetically insulated transmission line oscillator employs self-generated magnetic fields to generate microwave energy. An anode of the oscillator includes slow-wave structures which are formed of a plurality of thin conductive vanes defining cavities therebetween, and a gap is formed between the anode and a cathode of the oscillator. In response to a pulsed voltage applied to the anode and cathode, self-generated magnetic fields arfe produced in a cross-field orientation with respect to the orientation of the electric field between the anode and the cathode. The cross-field magnetic fields insulate the flow of electrons in the gap and confine the flow of electrons within the gap.

  20. Fractional Transmission Line with Losses

    NASA Astrophysics Data System (ADS)

    Gómez-Aguilar, José Francisco; Dumitru, Baleanu

    2014-11-01

    In this manuscript, the fractional transmission line with losses is presented. The order of the Caputo derivative is considered as 0 < β ≤ 1 and 0 < γ ≤ 1 for the fractional equation in space and time domain, respectively. Two cases are solved, with fractional spatial and fractional temporal derivatives, and also numerical simulations were carried out, where there are taken both derivatives in simultaneous form. Two parameters σx and σt are introduced and a physical relation between these parameters is reported. Solutions in space and time are given in terms of the Mittag-Leffler functions. The classic cases are recovered when β and γ are equal to 1.

  1. Superconducting transmission line particle detector

    DOEpatents

    Gray, K.E.

    1988-07-28

    A microvertex particle detector for use in a high energy physic collider including a plurality of parallel superconducting thin film strips separated from a superconducting ground plane by an insulating layer to form a plurality of superconducting waveguides. The microvertex particle detector indicates passage of a charged subatomic particle by measuring a voltage pulse measured across a superconducting waveguide caused by the transition of the superconducting thin film strip from a superconducting to a non- superconducting state in response to the passage of a charged particle. A plurality of superconducting thin film strips in two orthogonal planes plus the slow electromagnetic wave propagating in a superconducting transmission line are used to resolve N/sup 2/ ambiguity of charged particle events. 6 figs.

  2. Magnetically insulated transmission line oscillator

    DOEpatents

    Bacon, L.D.; Ballard, W.P.; Clark, M.C.; Marder, B.M.

    1987-05-19

    A magnetically insulated transmission line oscillator employs self-generated magnetic fields to generate microwave energy. An anode of the oscillator includes slow-wave structures which are formed of a plurality of thin conductive vanes defining cavities therebetween, and a gap is formed between the anode and a cathode of the oscillator. In response to a pulsed voltage applied to the anode and cathode, self-generated magnetic fields are produced in a cross-field orientation with respect to the orientation of the electric field between the anode and the cathode. The cross-field magnetic fields insulate the flow of electrons in the gap and confine the flow of electrons within the gap. 11 figs.

  3. Clean fog flashover tests on 138-kV nonceramic line post insulators before and after artificial aging

    SciTech Connect

    Schneider, H.M.; Guidi, W.W.; Howes, D.R. . High Voltage Transmission Research Center)

    1992-10-01

    This report describes research conducted to determine the contamination performance of [sup 138] kV transmission line insulators utilized by Florida Power and Light Co. Although test results for both ceramic and nonceramic insulators are reported, emphasis is placed on the performance of nonceramic line posts before and after artificial aging. Since it was not possible to obtain nonceramic insulators that were aged in the same environment and for the same amount of time, there was a need to develop an accelerated aging chamber in order to age these insulators artificially. The aging cycle for these tests is designed to represent the severe coastal climate of Florida. Aging is judged by physical observations, leakage current analysis during aging, analytical material measurements and contamination flashover voltage. Flashover performance is evaluated as a function of contamination severity as determined by equivalent salt deposit density (ESDD). Radio interference (RI), television interference (TVI) and audible noise (AN), during contamination flashover tests, are also described.

  4. Clean fog flashover tests on 138-kV nonceramic line post insulators before and after artificial aging. Final report

    SciTech Connect

    Schneider, H.M.; Guidi, W.W.; Howes, D.R.

    1992-10-01

    This report describes research conducted to determine the contamination performance of {sup 138} kV transmission line insulators utilized by Florida Power and Light Co. Although test results for both ceramic and nonceramic insulators are reported, emphasis is placed on the performance of nonceramic line posts before and after artificial aging. Since it was not possible to obtain nonceramic insulators that were aged in the same environment and for the same amount of time, there was a need to develop an accelerated aging chamber in order to age these insulators artificially. The aging cycle for these tests is designed to represent the severe coastal climate of Florida. Aging is judged by physical observations, leakage current analysis during aging, analytical material measurements and contamination flashover voltage. Flashover performance is evaluated as a function of contamination severity as determined by equivalent salt deposit density (ESDD). Radio interference (RI), television interference (TVI) and audible noise (AN), during contamination flashover tests, are also described.

  5. Pore mutants of HERG and KvLQT1 downregulate the reciprocal currents in stable cell lines

    PubMed Central

    Ren, Xiao-Qin; Liu, Gong Xin; Organ-Darling, Louise E.; Zheng, Renjian; Roder, Karim; Jindal, Hitesh K.; Centracchio, Jason; McDonald, Thomas V.

    2010-01-01

    We previously reported a transgenic rabbit model of long QT syndrome based on overexpression of pore mutants of repolarizing K+ channels KvLQT1 (LQT1) and HERG (LQT2).The transgenes in these rabbits eliminated the slow and fast components of the delayed rectifier K+ current (IKs and IKr, respectively), as expected. Interestingly, the expressed pore mutants of HERG and KvLQT1 downregulated the remaining reciprocal repolarizing currents, IKs and IKr, without affecting the steady-state levels of the native polypeptides. Here, we sought to further explore the functional interactions between HERG and KvLQT1 in heterologous expression systems. Stable Chinese hamster ovary (CHO) cell lines expressing KvLQT1-minK or HERG were transiently transfected with expression vectors coding for mutant or wild-type HERG or KvLQT1. Transiently expressed pore mutant or wild-type KvLQT1 downregulated IKr in HERG stable CHO cell lines by 70% and 44%, respectively. Immunostaining revealed a severalfold lower surface expression of HERG, which could account for the reduction in IKr upon KvLQT1 expression. Deletion of the KvLQT1 NH2-terminus did not abolish the downregulation, suggesting that the interactions between the two channels are mediated through their COOH-termini. Similarly, transiently expressed HERG reduced IKs in KvLQT1-minK stable cells. Coimmunoprecipitations indicated a direct interaction between HERG and KvLQT1, and surface plasmon resonance analysis demonstrated a specific, physical association between the COOH-termini of KvLQT1 and HERG. Here, we present an in vitro model system consistent with the in vivo reciprocal downregulation of repolarizing currents seen in transgenic rabbit models, illustrating the importance of the transfection method when studying heterologous ion channel expression and trafficking. Moreover, our data suggest that interactions between KvLQT1 and HERG are mediated through COOH-termini. PMID:20833965

  6. Coding for Single-Line Transmission

    NASA Technical Reports Server (NTRS)

    Madison, L. G.

    1983-01-01

    Digital transmission code combines data and clock signals into single waveform. MADCODE needs four standard integrated circuits in generator and converter plus five small discrete components. MADCODE allows simple coding and decoding for transmission of digital signals over single line.

  7. Transmission Line Security Monitor: Final Report

    SciTech Connect

    John Svoboda

    2011-04-01

    The Electric Power Transmission Line Security Monitor System Operational Test is a project funded by the Technical Support Working Group (TSWG). TSWG operates under the Combating Terrorism Technical Support Office that functions under the Department of Defense. The Transmission Line Security Monitor System is based on technology developed by Idaho National Laboratory. The technology provides a means for real-time monitoring of physical threats and/or damage to electrical transmission line towers and conductors as well as providing operational parameters to transmission line operators to optimize transmission line operation. The end use is for monitoring long stretches of transmission lines that deliver electrical power from remote generating stations to cities and industry. These transmission lines are generally located in remote transmission line corridors where security infrastructure may not exist. Security and operational sensors in the sensor platform on the conductors take power from the transmission line and relay security and operational information to operations personnel hundreds of miles away without relying on existing infrastructure. Initiated on May 25, 2007, this project resulted in pre-production units tested in realistic operational environments during 2010. A technology licensee, Lindsey Manufacturing of Azusa California, is assisting in design, testing, and ultimately production. The platform was originally designed for a security monitoring mission, but it has been enhanced to include important operational features desired by electrical utilities.

  8. RF Transmission Lines on Silicon Substrates

    NASA Technical Reports Server (NTRS)

    Ponchak, George E.

    1999-01-01

    A review of RF transmission lines on silicon substrates is presented. Through measurements and calculated results, it is shown that attenuation is dominated by conductor loss if silicon substrates with a resistivity greater than 2500 Ohm-cm are used. Si passivation layers affect the transmission line attenuation; however, measured results demonstrate that passivation layers do not necessarily increase attenuation. If standard, low resistivity Si wafers must be used, alternative transmission lines such as thin film microstrip and Co-Planar Waveguide (CPW) on thick polyimide layers must be used. Measured results presented here show that low loss per unit length is achievable with these transmission lines.

  9. Detonator comprising a nonlinear transmission line

    DOEpatents

    Elizondo-Decanini, Juan M

    2014-12-30

    Detonators are described herein. In a general embodiment, the detonator includes a nonlinear transmission line that has a variable capacitance. Capacitance of the nonlinear transmission line is a function of voltage on the nonlinear transmission line. The nonlinear transmission line receives a voltage pulse from a voltage source and compresses the voltage pulse to generate a trigger signal. Compressing the voltage pulse includes increasing amplitude of the voltage pulse and decreasing length of the voltage pulse in time. An igniter receives the trigger signal and detonates an explosive responsive to receipt of the trigger signal.

  10. Recent progress of the improved magnetically insulated transmission line oscillator.

    PubMed

    Fan, Yu-Wei; Zhong, Hui-Huang; Li, Zhi-Qiang; Shu, Ting; Zhang, Jian-De; Liu, Jin-Liang; Yang, Jian-Hua; Zhang, Jun; Yuan, Cheng-Wei; Luo, Ling

    2008-03-01

    The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube driven by a 550 kV, 57 kA, 50 ns electron beam. It has allowed us to generate 2.4 GW pulse of 22 ns duration. The recent progress of the improved MILO is presented in this paper. First, a field shaper cathode is introduced into the improved MILO to avoid the cathode flares in the triple point region. The experimental results show that the cathode flares are avoided, so the lifetime of the velvet cathode is longer than that of the taper cathode. Furthermore, the shot-to-shot reproducibility is better than that of the taper cathode. Second, In order to prolong the pulse duration and increase the radiated microwave power, a self-built 600 kV, 10 Omega, 80 ns pulser: SPARK-03 is employed to drive the improved MILO. Simulation and experimental investigation are performed. In simulation, when the improved MILO is driven by a 600 kV, 57 kA electron beam, high-power microwave is generated with output power of 4.15 GW, frequency of 1.76 GHz, and relevant power conversion efficiency of 12.0%. In experiments, when the diode voltage is 550 kV and current is 54 kA, the measured results are that the radiated microwave power is above 3.1 GW, the pulse duration is above 40 ns, the microwave frequency is about 1.755 GHz, and the power conversion efficiency is about 10.4%.

  11. Current densities and total contact currents associated with 400 kV power line tasks.

    PubMed

    Korpinen, Leena; Kuisti, Harri; Elovaara, Jarmo

    2013-12-01

    The aim of the study was to analyze all current values from measured periods while performing tasks on 400 kV power lines. Our aim was also to study the average current densities and average total contact currents caused by electric fields in 400 kV power line tasks. Two workers simulated the following tasks: (A) climbing up a portal tower, (B) climbing up a portal transposing tower, (C) working on the cross-arm of a portal tower, (D) climbing up a portal tube tower, (E) climbing up a Tannenbaum tower on the side of the energized circuit with the other circuit unenergized, (F) climbing up a Tannenbaum tower with both circuits energized, and (G) climbing up a Donau tower. The highest average current density in the neck was 2.5 mA/m(2) (calculated internal electric field 31.5-63.0 mV/m), and the highest average of the contact currents was 240.0 µA. All measured values at 400 kV towers were lower than the limit value of 10 mA/m(2) in the first version of Directive 2004/40/EC and the basic restrictions (0.1 and 0.8 V/m) of the International Commission on Non-ionizing Radiation Protection.

  12. Transient overvoltages and overcurrents on 12. 47 kV distribution lines: Computer modeling results

    SciTech Connect

    Kolcio, N.; Halladay, J.A.; Allen, G.D.; Fromholtz, E.N. )

    1993-01-01

    American Electric Power conducted field tests to study transient overvoltages and overcurrents on a 12.47 kV distribution line. A separate paper has reported on the field test results. This paper covers the computer modeling and simulation of the field tests. The paper describes the adaptation and refinement of the transformer, load and line models. Computer simulation of the field tests using the Electromagnetic Transients Program (EMTP) give results which are very close to the actual field tests. Also reported in the paper are the results from a parametric study which were utilized to develop a simplified computer model.

  13. 75 FR 9573 - Minnkota Power Cooperative, Inc: Bemidji-Grand Rapids 230kV Transmission Project

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-03

    ... Rural Utilities Service Minnkota Power Cooperative, Inc: Bemidji-Grand Rapids 230kV Transmission Project... between the Wilton Substation near Bemidji, Minnesota, and the Boswell Substation near Grand Rapids... Community Library, 223 Cedar Ave. NW., Cass Lake, MN 56633; Grand Rapids Area Library, 140 NE 2nd Street...

  14. 18 CFR 2.2 - Transmission lines.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Transmission lines. 2.2 Section 2.2 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF... Under the Federal Power Act § 2.2 Transmission lines. In a public statement dated March 7, 1941, the...

  15. 18 CFR 2.2 - Transmission lines.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Transmission lines. 2.2 Section 2.2 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF... Under the Federal Power Act § 2.2 Transmission lines. In a public statement dated March 7, 1941, the...

  16. Modeling and Simulation of Nonlinear Transmission Lines

    DTIC Science & Technology

    2010-01-01

    Modeling and Simulation of Nonlinear Transmission Lines by Frank Crowne ARL -TR-5062 January 2010...longer needed. Do not return it to the originator. Army Research Laboratory Adelphi, MD 20783-1197 ARL -TR-5062 January 2010 Modeling...and Simulation of Nonlinear Transmission Lines Frank Crowne Sensors and Electron Devices Directorate, ARL

  17. Transmission line component testing for the ITER Ion Cyclotron Heating and Current Drive System

    NASA Astrophysics Data System (ADS)

    Goulding, Richard; Bell, G. L.; Deibele, C. E.; McCarthy, M. P.; Rasmussen, D. A.; Swain, D. W.; Barber, G. C.; Barbier, C. N.; Cambell, I. H.; Moon, R. L.; Pesavento, P. V.; Fredd, E.; Greenough, N.; Kung, C.

    2014-10-01

    High power RF testing is underway to evaluate transmission line components for the ITER Ion Cyclotron Heating and Current Drive System. The transmission line has a characteristic impedance Z0 = 50 Ω and a nominal outer diameter of 305 mm. It is specified to carry up to 6 MW at VSWR = 1.5 for 3600 s pulses, with transient voltages up to 40 kV. The transmission line is actively cooled, with turbulent gas flow (N2) used to transfer heat from the inner to outer conductor, which is water cooled. High voltage and high current testing of components has been performed using resonant lines generating steady state voltages of 35 kV and transient voltages up to 60 kV. A resonant ring, which has operated with circulating power of 6 MW for 1 hr pulses, is being used to test high power, low VSWR operation. Components tested to date include gas barriers, straight sections of various lengths, and 90 degree elbows. Designs tested include gas barriers fabricated from quartz and aluminum nitride, and transmission lines with quartz and alumina inner conductor supports. The latest results will be presented. This manuscript has been authored by UT-Battelle, LLC, under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy.

  18. Hunter survey final report, Phase I - baseline study. Garrison-Spokane 500-kV transmission project

    SciTech Connect

    Allen, S.

    1984-11-01

    The State of Montana, in cooperation with the US Forest Service and the Bonneville Power Administration, is conducting a five-year study on the impacts on elk security habitat and hunter opportunity in western Montana of a 500 kV transmission line. Potential impacts stem from the new and upgraded access roads required for the line, which may reduce summer/fall security habitat and make hunting areas less remote. The line itself could affect the aesthetics of popular hunting areas located along the route. As part of this monitoring program, the Montana Department of Natural Resources and Conservation is surveying hunters at seven check stations in the project's two study areas. The hunter survey research has three phases. Phase I was conducted in fall, 1983, to collect baseline data on hunting use and quality in the study areas. After the line is constructed and energized, the Phase II survey, scheduled for fall, 1985, will test hypotheses developed from baseline data to assess the project's impacts on hunting use. During Phase III, scheduled for fall, 1986, the persistence of any impacts identified will be measured. Reports from each phase will be issued to the Interagency Wildlife Technical Committee (chaired by the Bonneville Power Administration). The data will also be used by the Montana Department of Fish, Wildlife, and Parks, both to help manage elk and to assist in US Forest Service Land management planning. Over 600 hunters were interviewed using a questionnaire developed by DNRC and reviewed extensively by state and federal agencies. The survey form contained questions on hunters' reasons for choosing the study areas as places to hunt, hunting success and related information, previous hunting experience, hunting area evaluations, place of residence, and age. The data were tabulated to describe the 1983 baseline data, and then subjected to cluster analysis. 36 references, 1 figure, 9 tables. (ACR)

  19. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-25) - Ostrander-Pearl Transmission Line

    SciTech Connect

    Stratton, Elaine S.

    2001-09-05

    Vegetation Management along selected ROW sections of the Ostrander-Pearl transmission line. The ROWs include sections of the Ostrander-Pearl 500 kV line; the Ostrander-McLoughlin 500 kV line; the Big Eddy-Chemawa 230 kV line and the Big Eddy-McLoughlin 230 kV line. BPA proposes to clear unwanted vegetation in the rights-of-way and around tower structures that may impede the operation and maintenance of the subject transmission lines. The project also includes clearing approximately 3 miles of access road and cutting of some danger trees. All work will be in accordance with the National Electrical Safety Code and BPA Standards. BPA plans to conduct vegetation control with the goal of removing tall-growing vegetation that is currently or will soon be a hazard to the transmission lines and to promote low-growing plant communities in the right-of-way and to clear vegetation from new rights-of-way corridors.

  20. Cardiac pacemakers in electric and magnetic fields of 400-kV power lines.

    PubMed

    Korpinen, Leena; Kuisti, Harri; Elovaara, Jarmo; Virtanen, Vesa

    2012-04-01

    The cardiac pacemaker (PM) implantation rate per million is high. Earlier studies have found interference to PMs by electromagnetic fields. The aim of the study is to investigate disturbances in cardiac PM using a human-shaped phantom in electric and magnetic fields of 400-kV power lines. The phantom was used in the following manner: isolated from the ground, grounded from left or right foot, or grounded from left or right hand. Out of the tested PMs one had such a disturbance that it set the pace 60 times per minute, when the electric field was 6.7-7.5 kV/m and the magnetic field was 2.4-2.9 μT. The electrode configuration of the PM was unipolar. In bipolar configuration, the same PM had no disturbance. During the test period, other PMs only had minor disturbances or none at all. Some PMs do not record time information for minor disturbances. In such cases, it was impossible to link the disturbances to the exposure under the power line. The electric field under a 400-kV power line may disturb a PM. However, only one type out of several tested PMs showed a major disturbance and that was only with a unipolar electrode configuration. The risk of disturbances is therefore not deemed to be high. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  1. Calculation method for line loss in 10kV distribution grid planning

    NASA Astrophysics Data System (ADS)

    Xiao, Ming-hui; Lin, Ling-xue; Liu, Si-yuan

    2017-01-01

    Distribution grid line loss index is an important indicator of running and managing a distribution grid. A general feature in distribution network is its difficulty in gathering data about structure and operation. Based on its feature, this paper proposed a method for calculating line loss in 10kV distribution grid from the perspective of planning. According to the characteristics of power consumption on different location of the feeder, line loss can be divided into three parts, including the main line loss, the loss of branch line and the loss of distribution transformer. The proposed method achieved quick calculation and component analysis. Distributed coefficient was calculated by analyzing different distributed situation of load on feeder and the equivalent loss power on main line was calculated. Branch line and distribution transformer were equivalent to a resistance located at the head of the line to match the real power consumption. With the data acquirement, accuracy can be improved. Finally, the example of different power supply zone was calculated based on the method. The comparison between the calculated results and technical guidelines of southern power grid indicated the components of the line loss and put forward solutions for loss reduction. The method proposed overcame disadvantage of strong dependence on complete and precise data, which fits for planning work.

  2. Mitigation of bird collisions with transmission lines: Final report

    SciTech Connect

    Beaulaurier, D.L.

    1981-09-11

    In this study removal of overhead groundwires was evaluated as a technique for mitigating bird collisions with transmission lines. Groundwires were removed by BPA from a 500 kV double circuit line at Bybee Lake in Portland, Oregon. Earlier studies at these sites had documented small but measurable collision rates (i.e., No. collisions/No. flights) attributed primarily to collisions with groundwires. Observations of bird flights and searches for dead birds in the vicinity of the lines constituted the primary methods of data collection during pre- and post-removal studies. Field work was conducted from October 1980 through March 1981. A total of seven dead birds and eight feather spots were found after groundwire removal. Species found were green-winged teal, pintail, greater scaup, American wigeon, glaucous-winged gull, starling, red-winged blackbird and song sparrow. No collisions with transmission lines were observed. During pre-removal studies at these two sites, a total of 53 dead birds and 22 feather spots were found over two years of study. It was necessary to document flight intensity (No. flights/day) during pre- and post-removal studies, in order to determine if the number of dead birds found changed because of groundwire removal or simply because of changes in flight intensity. 41 refs., 18 figs., 22 tabs.

  3. Single transmission line data acquisition system

    DOEpatents

    Fasching, George E.

    1984-01-01

    A single transmission line interrogated multiple channel data acquisition system is provided in which a plurality of remote station/sensors monitor specific process variables and transmit measurement values over the single transmission line to a master station when addressed by the master station. Power for all remote stations (up to 980) is provided by driving the line with constant voltage supplied from the master station and automatically maintained independent of the number of remote stations directly connected to the line. The transmission line can be an RG-62 coaxial cable with lengths up to about 10,000 feet with branches up to 500 feet. The remote stations can be attached randomly along the line. The remote stations can be scanned at rates up to 980 channels/second.

  4. Novel adaptive distance relay algorithm considering the operation of 154 kV SFCL in Korean power transmission system

    NASA Astrophysics Data System (ADS)

    Lee, S.; Lee, J.; Song, S.; Yoon, J.; Lee, B.

    2015-11-01

    In general, SFCLs can have a negative impact on the protective coordination in power transmission system because of the variable impedance of SFCLs. It is very important to solve the protection problems of the power system for the successful application of SFCLs to real power transmission system. This paper reviews some protection problems which can be caused by the application of 154 kV SFCLs to power transmission systems in South Korea. And then we propose an adaptive protection algorithm to solve the problems. The adaptive protection algorithm uses the real time information of the SFCL system operation.

  5. Electrical Transmission Line Diametrical Retention Mechanism

    DOEpatents

    Hall, David R.; Hall, Jr., H. Tracy; Pixton, David; Dahlgren, Scott; Sneddon, Cameron; Briscoe, Michael; Fox, Joe

    2006-01-03

    The invention is a mechanism for retaining an electrical transmission line. In one embodiment of the invention it is a system for retaining an electrical transmission line within downhole components. The invention allows a transmission line to be attached to the internal diameter of drilling components that have a substantially uniform drilling diameter. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmission line to withstand the tension and compression of drill pipe during routine drilling cycles.

  6. Study of electric field and ion effects on HVDC lines. Technical progress report No. 2, July 1-September 30, 1980. [Tests at 950, 1050, and 1200 kV

    SciTech Connect

    Comber, M.G.; Johnson, G.B.

    1980-01-01

    Progress is reported in research aimed at measuring and defining the electrical environment in the vicinity of HVDC transmission lines, predicting this electrical environment for any HVDC line design, and providing information on this electrical environment to bio-effects researchers. Methods for measuring ground-level electric field and ion current density are described and data from electrostatic field measurements for lines at 950, 1050, and 1200 kV are presented. (LCL)

  7. Implantable cardioverter defibrillators in electric and magnetic fields of 400 kV power lines.

    PubMed

    Korpinen, Leena; Kuisti, Harri; Elovaara, Jarmo; Virtanen, Vesa

    2014-03-01

    Implantable cardioverter defibrillator (ICD) therapy has increased in Western countries. The aim of the study was to investigate the function of ICDs using a human-shaped phantom in electric and magnetic fields of 400 kV power lines. The phantom was used in the following manner: isolated from the ground, earthed from a foot, or earthed from a hand. We performed 37 ICD tests using 10 different ICD devices. When the electric fields varied from 6.8 kV/m to 7.5 kV/m (humidity 70.5%) and the magnetic field was 2.0 μT, one of the ICDs tested recorded 258 ventricular beats/min when a simulated heart signal was applied to ICD electrodes. When the exposure was 5.1 kV/m, the same ICD had a similar disturbance; however, in a 0.9 kV/m field, it worked correctly. Consequently, no effect on ICDs functioning was observed up to 0.9 kV/m, while anomalous behavior in some conditions was observed when levels exceeded 5.1 kV/m; ICD malfunctioning seems possible within 11.5 m from 400 kV power lines or in conditions inducing exposures exceeding 5 kV/m. Further development of this research field is needed. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  8. Electrostatic Unbalances of Transmission Lines.

    DTIC Science & Technology

    1985-08-01

    RD-A±68 742 ELECTROSTATIC UMBALANCES OF TEMNISSION LINES(U) AIR 1V2 FORCE INST OF TECH WRIGHNT-PATTERSON AFD OH J NOUIKOWSKI AUG 85 AFIT/CI/ NR -BS...CONTROLLING OFFICE NAME AND ADORESS 12. REPORT DATE AFIT/ NR 1985 WPAFB OH 45433 - 6583 1i. NUMBER OF PAGES ___102 14. MONITORING AGENCY NAME & ADDRESS...return it to: AF IT/ NR Wright-Patterson AFB OH 45433 RESEARCH TITLE: Electrostatic Unbalances oJCTransmission Lines *AUTHOR: Jioseph Nowikowski

  9. 60-Hertz electric-field exposures in transmission line towers.

    PubMed

    Bracken, T; Senior, Russell; Dudman, Joseph

    2005-09-01

    This article reports on an investigation of 60-Hz electric-field exposures of line workers in 230- to 765-kV transmission line towers. The exposures were based on computations of the unperturbed electric field along climbing routes and at work positions on the towers and on insulated ladders suspended in towers. Computed exposures were expressed in terms of the unperturbed electric field averaged over the body as stipulated by guidelines. For the realistic on-tower positions, the worker's posture, the uniformity of the field, and the field orientation differed from the guideline exposure scenario of standing erect in a vertical uniform field. These differences suggest the need for care in comparing electric-field exposures in towers with guideline limits. The unperturbed nonuniform fields at discrete points near steel and aluminum lattice structures were computed using Monte Carlo methods that model surface and spatial electric fields on and near standard geometrical elements. To estimate a whole-body average, fields were computed at 10 discrete points positioned on segments of an articulated stick-figure model of the human body. The whole-body average field was computed from fields at all the points weighted by the fraction of body volume that the corresponding segment represented. We estimated the average unperturbed electric field, the space potential at the torso, and the induced short-circuit current for 19 climbing and work positions in six towers. The maximum average electric-field exposure during climbing ranged from 10 kV/m for a 230-kV tower to 31 kV/m for a 765-kV tower. Exposures at on-tower work positions were lower than the estimated maximum exposures during climbing. For 500- and 765-kV towers, computed exposures while climbing and at some on-tower positions exceeded the limit of 20 kV/m given in the recently adopted IEEE Standard C95.6 2002. For lower voltage towers, exposures did not exceed 20 kV/m.

  10. Note: Fast double pulse system using transmission line characteristic of the pulse forming line

    NASA Astrophysics Data System (ADS)

    Sharma, Surender Kumar; Deb, P.; Sharma, Archana; Shyam, A.

    2012-11-01

    A fast double pulse system is designed and developed using the transmission line characteristic of the pulse forming line to generate two flat top rectangular pulses with extremely short interpulse repetition interval. The helical pulse forming line (HPFL) is used to generate longer duration rectangular pulses in smaller length. The HPFL inner conductor is made up of 13 turns of SS-304 strip, 39.5 mm wide and 0.5 mm thick wounded on the 168 mm delrin cylinder. The impedance of the HPFL is 22 Ω. The 2 turns at the input side of the HPFL are wounded with ethylene propylene rubber tape on the strip. The HPFL is charged to 180 kV in 4 μs and discharges into a matched load through a spark switch. It generates two flat top rectangular pulses of 90 kV, 100 ns duration with the 30 ns interval between the pulses. The system can be used as fast double pulse source for repetitive pulsed power loads.

  11. Note: fast double pulse system using transmission line characteristic of the pulse forming line.

    PubMed

    Sharma, Surender Kumar; Deb, P; Sharma, Archana; Shyam, A

    2012-11-01

    A fast double pulse system is designed and developed using the transmission line characteristic of the pulse forming line to generate two flat top rectangular pulses with extremely short interpulse repetition interval. The helical pulse forming line (HPFL) is used to generate longer duration rectangular pulses in smaller length. The HPFL inner conductor is made up of 13 turns of SS-304 strip, 39.5 mm wide and 0.5 mm thick wounded on the 168 mm delrin cylinder. The impedance of the HPFL is 22 Ω. The 2 turns at the input side of the HPFL are wounded with ethylene propylene rubber tape on the strip. The HPFL is charged to 180 kV in 4 μs and discharges into a matched load through a spark switch. It generates two flat top rectangular pulses of 90 kV, 100 ns duration with the 30 ns interval between the pulses. The system can be used as fast double pulse source for repetitive pulsed power loads.

  12. Effect of tornado loads on transmission lines

    SciTech Connect

    Ishac, M.F.; White, H.B.

    1995-01-01

    Of all the populated areas in Canada, southwestern Ontario has experienced the highest tornado incidence and faces the greatest tornado damage. About 1 or 2 tornadoes per 10,000 km{sup 2} can be expected there annually. The probability of a tornado strike at a given point is very small but the probability of a transmission line being crossed by a tornado is significant. The purpose of this paper is to review the literature related to tornadoes in Ontario and to investigate the effect of tornado loads on transmission lines. Based on this investigation a design basis tornado loading for transmission towers is proposed.

  13. Effect of tornado loads on transmission lines

    SciTech Connect

    Ishac, M.F.; White, H.B.

    1994-12-31

    Of all the populated areas in Canada, southwestern Ontario has experienced the highest tornado incidence and faces the greatest tornado damage. About 1 or 2 tornadoes per 10,000 km{sup 2} can be expected there annually. The probability of a tornado strike at a given point is very small but the probability of a transmission line being crossed by a tornado is significant. The purpose of this paper is to review the literature related to tornadoes in Ontario and to investigate the effect of tornado loads on transmission lines. Based on this investigation a design basis tornado loading for transmission towers is proposed.

  14. Concurrent Wind Cooling in Power Transmission Lines

    SciTech Connect

    Jake P Gentle

    2012-08-01

    Idaho National Laboratory and the Idaho Power Company, with collaboration from Idaho State University, have been working on a project to monitor wind and other environmental data parameters along certain electrical transmission corridors. The combination of both real-time historical weather and environmental data is being used to model, validate, and recommend possibilities for dynamic operations of the transmission lines for power and energy carrying capacity. The planned results can also be used to influence decisions about proposed design criteria for or upgrades to certain sections of the transmission lines.

  15. Load-resistant coaxial transmission line

    DOEpatents

    Hall, David R.; Fox, Joe

    2006-01-03

    A transmission line for downhole tools that make up all or part of a tool string for drilling and production of oil, gas, and geothermal wells that can withstand the dynamic gravitational forces and other accelerations associated with downhole excavations. The transmission line has a metal tube, or outer conductor, that houses a coaxial wire inner conductor. A non-metallic dielectric material is interposed between the inner and outer conductors. The outer and inner conductors and the dielectric are sufficiently compressed together so that independent motion between them is abated. Compression of the components of the transmission line may be achieved by drawing the transmission through one or more dies in order to draw down the outer conductor onto the dielectric, or by expanding the inner conductor against the dielectric using a mandrel or hydraulic pressure. Non-metallic bead segments may be used in aid of the compression necessary to resist the dynamic forces and accelerations of drilling.

  16. Conceptual design for transmission line inspection robot

    NASA Astrophysics Data System (ADS)

    Jalal, M. F. Abdul; Sahari, K. S. Mohamed; Anuar, A.; Mohd Arshad, A. D.; Idris, M. S.

    2013-06-01

    Power transmission line is used for power distribution purposes due to their cost effective measure compared to underlying cable. However, prolonged exposure to natural weather may cause fatigue stress to the lines as well as induce material failure. Therefore, periodical line inspection is considered uttermost important as a preventive measure to avoid power outage. However, transmission line inspection has always been a high risk and expensive work. Hazardous works that may harm operator as well as routine that requires precise handling can be performed by robots. Various types of robots have been designed and developed for line inspection but only perform well on a straight and continuous line. As these robots encounter an obstacle during the inspection, then the real problem in terms of robot stability and smooth operation arises. In this paper, conceptual design and evaluation for transmission line inspection robot is presented. The inspection robot mobile robot must be able to bypass or avoid obstacles as it travels along the power transmission line.

  17. Evaluation of current densities and total contact currents in occupational exposure at 400 kV substations and power lines.

    PubMed

    Korpinen, Leena H; Elovaara, Jarmo A; Kuisti, Harri A

    2009-04-01

    This investigation studied the current densities in the neck and total contact currents in occupational exposure at 400 kV substations and power lines. Eight voluntary workers simulated their normal work tasks using the helmet-mask measuring system. In all, 151 work tasks with induced current measurements were made. Work situations were: tasks in 400 kV substations, tasks in 400-110 kV towers and the cutting of vegetation under 400 kV power lines. The average current density in the neck was estimated from the current induced in the helmet. The calculated maximum average current densities in the neck varied from 1.5 to 6.4 mA/m(2) and the maximum total contact currents from 66.8 to 458.4 microA. The study shows that the maximum average current densities and the total contact currents (caused by electric field) in occupational exposure at 400 kV substations and power lines does not exceed the limit and action values (10 mA/m(2) and 1 mA) of the new EU-directive 2004/40/EC (live-line bare-hand works excluded). (c) 2009 Wiley-Liss, Inc.

  18. Construction and Application of Theoretical Line Loss Calculation Platform for 220 kV and above Power Grid in Shanghai

    NASA Astrophysics Data System (ADS)

    Yang, F.; Liu, J.; Li, S. Q.

    2017-05-01

    Instead of drawing power grid and inputting component parameters manually to establish calculation model, the theoretical line loss calculation platform for 220 kV and above power grid in Shanghai is developed based on grid dispatching D5000 system, capable of capturing real-time power grid basic / operational data and offline graphics saving. It resolves all data for previous day automatically before commencing theoretical line loss calculation. The theoretical line loss calculation results for 500 / 220 kV showed its validity and accuracy. The project effectively accumulates the scientific data and promote State Grid Shanghai Municipal Electric Power Company to fully grasp the related equipment operating conditions of Shanghai 500 / 220kV power grid. The analysis results not only help power company to guide production practice, but also provide a better understanding for power grid weakness and loss composition, which enables power company managers to guide future construction and transformation of power grid accurately and effectively.

  19. Study on the principle of intelligent helmet's electric alarm device in transmission line

    NASA Astrophysics Data System (ADS)

    Zhang, Zehao; Peng, Lin; Bao, Xingchuan; Zhu, Liang; Wang, He; Zhou, Qiang

    2017-08-01

    This thesis made study on the Principle of Intelligent Helmet's Electric Alarm Device in Transmission Line. Based on the simulation analysis of the electric field strength and electric field characteristics of three-phase 10kV transmission line, this thesis put forward the calculation method of the electric alarm distance by developing a calculation model, and then explains proof of the accuracy of intelligent helmet's electric alarm and discusses its theoretical basis. At last, the theoretical analysis' correctness and the measurement's accuracy of the intelligent helmet's electric alarm device is proved by tests.

  20. Transmission Line Adapted Analytical Power Charts Solution

    NASA Astrophysics Data System (ADS)

    Sakala, Japhet D.; Daka, James S. J.; Setlhaolo, Ditiro; Malichi, Alec Pulu

    2017-08-01

    The performance of a transmission line has been assessed over the years using power charts. These are graphical representations, drawn to scale, of the equations that describe the performance of transmission lines. Various quantities that describe the performance, such as sending end voltage, sending end power and compensation to give zero voltage regulation, may be deduced from the power charts. Usually required values are read off and then converted using the appropriate scales and known relationships. In this paper, the authors revisit this area of circle diagrams for transmission line performance. The work presented here formulates the mathematical model that analyses the transmission line performance from the power charts relationships and then uses them to calculate the transmission line performance. In this proposed approach, it is not necessary to draw the power charts for the solution. However the power charts may be drawn for the visual presentation. The method is based on applying derived equations and is simple to use since it does not require rigorous derivations.

  1. Transmission Line Adapted Analytical Power Charts Solution

    NASA Astrophysics Data System (ADS)

    Sakala, Japhet D.; Daka, James S. J.; Setlhaolo, Ditiro; Malichi, Alec Pulu

    2016-08-01

    The performance of a transmission line has been assessed over the years using power charts. These are graphical representations, drawn to scale, of the equations that describe the performance of transmission lines. Various quantities that describe the performance, such as sending end voltage, sending end power and compensation to give zero voltage regulation, may be deduced from the power charts. Usually required values are read off and then converted using the appropriate scales and known relationships. In this paper, the authors revisit this area of circle diagrams for transmission line performance. The work presented here formulates the mathematical model that analyses the transmission line performance from the power charts relationships and then uses them to calculate the transmission line performance. In this proposed approach, it is not necessary to draw the power charts for the solution. However the power charts may be drawn for the visual presentation. The method is based on applying derived equations and is simple to use since it does not require rigorous derivations.

  2. Low-noise cryogenic transmission line

    NASA Technical Reports Server (NTRS)

    Norris, D.

    1987-01-01

    New low-noise cryogenic input transmission lines have been developed for the Deep Space Network (DSN) at 1.668 GHz for cryogenically cooled Field Effect Transistors (FET) and High Electron Mobility Transistor (HEMT) amplifiers. These amplifiers exhibit very low noise temperatures of 5 K to 15 K, making the requirements for a low-noise input transmission line critical. Noise contribution to the total amplifier system from the low-noise line is less than 0.5 K for both the 1.668-GHz and 2.25-GHz FET systems. The 1.668-GHz input line was installed in six FET systems which were implemented in the DSN for the Venus Balloon Experiment. The 2.25-GHz input line has been implemented in three FET systems for the DSN 34-m HEF antennas, and the design is currently being considered for use at higher frequencies.

  3. Transmission Characteristics Simulation on Power Line Communications

    NASA Astrophysics Data System (ADS)

    Kitayama, Masashi; Nakabayashi, Miyuki; Abe, Junichi; Tanabe, Shinji

    In Power Line Communication (PLC) systems, medium and low voltage power distribution lines are used as a communication network. However, since no consideration is given to signal transmission characteristics in the high frequency used for PLC systems, reflections caused by impedance mismatches deteriorate transmission characteristics. If channel characteristics of power lines can be estimated by simulation, it will be efficient for the design and the operation of PLC networks. This paper proposes a method to estimate transmission characteristics of a channel model between a transmitter and a receiver installed on a distribution network. Propagation characteristics of PLC signals at each distribution facility is described using two port networks. A channel model is automatically generated from the combination of component models along the topology of distribution network and the locations of a transmitter and a receiver. The proposed method was validated using measurement data of a test distribution network and was proved to be effective.

  4. Robust hyperchaotic synchronization via analog transmission line

    NASA Astrophysics Data System (ADS)

    Sadoudi, S.; Tanougast, C.

    2016-02-01

    In this paper, a novel experimental chaotic synchronization technique via analog transmission is discussed. We demonstrate through Field-Programmable Gate Array (FPGA) implementation design the robust synchronization of two embedded hyperchaotic Lorenz generators interconnected with an analog transmission line. The basic idea of this work consists in combining a numerical generation of chaos and transmitting it with an analog signal. The numerical chaos allows to overcome the callback parameter mismatch problem and the analog transmission offers robust data security. As application, this technique can be applied to all families of chaotic systems including time-delayed chaotic systems.

  5. Flux cloning in Josephson transmission lines.

    PubMed

    Gulevich, D R; Kusmartsev, F V

    2006-07-07

    We describe a novel effect related to the controlled birth of a single Josephson vortex. In this phenomenon, the vortex is created in a Josephson transmission line at a T-shaped junction. The "baby" vortex arises at the moment when a "mother" vortex propagating in the adjacent transmission line passes the T-shaped junction. In order to give birth to a new vortex, the mother vortex must have enough kinetic energy. Its motion can also be supported by an externally applied driving current. We determine the critical velocity and the critical driving current for the creation of the baby vortices and briefly discuss the potential applications of the found effect.

  6. EC Transmission Line Risk Identification and Analysis

    SciTech Connect

    Bigelow, Tim S

    2012-04-01

    The purpose of this document is to assist in evaluating and planning for the cost, schedule, and technical project risks associated with the delivery and operation of the EC (Electron cyclotron) transmission line system. In general, the major risks that are anticipated to be encountered during the project delivery phase associated with the implementation of the Procurement Arrangement for the EC transmission line system are associated with: (1) Undefined or changing requirements (e.g., functional or regulatory requirements) (2) Underperformance of prototype, first unit, or production components during testing (3) Unavailability of qualified vendors for critical components Technical risks associated with the design and operation of the system are also identified.

  7. Flux Cloning in Josephson Transmission Lines

    SciTech Connect

    Gulevich, D.R.; Kusmartsev, F.V.

    2006-07-07

    We describe a novel effect related to the controlled birth of a single Josephson vortex. In this phenomenon, the vortex is created in a Josephson transmission line at a T-shaped junction. The 'baby' vortex arises at the moment when a 'mother' vortex propagating in the adjacent transmission line passes the T-shaped junction. In order to give birth to a new vortex, the mother vortex must have enough kinetic energy. Its motion can also be supported by an externally applied driving current. We determine the critical velocity and the critical driving current for the creation of the baby vortices and briefly discuss the potential applications of the found effect.

  8. 18 CFR 2.2 - Transmission lines.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Transmission lines. 2.2 Section 2.2 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY GENERAL RULES GENERAL POLICY AND INTERPRETATIONS Statements of General Policy and Interpretations...

  9. 18 CFR 2.2 - Transmission lines.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Transmission lines. 2.2 Section 2.2 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY GENERAL RULES GENERAL POLICY AND INTERPRETATIONS Statements of General Policy and Interpretations...

  10. 18 CFR 2.2 - Transmission lines.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Transmission lines. 2.2 Section 2.2 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY GENERAL RULES GENERAL POLICY AND INTERPRETATIONS Statements of General Policy and Interpretations...

  11. Stabilizing Fiber-Optic Transmission Lines

    NASA Technical Reports Server (NTRS)

    Lutes, G. F.; Lau, K. Y.

    1984-01-01

    Voltage-controlled optical phase shifter is key. Optical phase shifter stabilizes propagation delay of fiber-optic transmission line by compensating for temperature and pressure effects. Applicable to phased array antenna systems and very-long-baseline interferometer distribution systems.

  12. 60 GHz Tapered Transmission Line Resonators

    DTIC Science & Technology

    2008-09-15

    DARPA TEAM program (contract no. DAAB07-02-1- L428 ), Motorola, and the UC-Micro program. 60 GHz Tapered Transmission Line Resonators by...0403427, wafer fabrication donation by STMicroelectronics, DARPA TEAM program (con- tract no. DAAB07-02-1- L428 ), Motorola, and the UC-Micro program. 1

  13. 49 CFR 192.706 - Transmission lines: Leakage surveys.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Transmission lines: Leakage surveys. 192.706... Transmission lines: Leakage surveys. Leakage surveys of a transmission line must be conducted at intervals not exceeding 15 months, but at least once each calendar year. However, in the case of a transmission line...

  14. 78 FR 60273 - Granby Pumping Plant Switchyard-Windy Gap Substation Transmission Line Rebuild, Grand County...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-01

    .... Western proposes to rebuild the single-circuit line as a double-circuit line, increase the voltage rating to 138-kV, and operate one circuit at 69-kV and the second at 138-kV. One circuit would replace... in the Alva B. Adams Tunnel is no longer operable. The second circuit was requested by...

  15. Canby Area Service Project substation and associated transmission line. Environmental Assessment

    SciTech Connect

    Not Available

    1992-02-01

    Bonneville Power Administration (BPA) provides power to Surprise Valley Electrification Corporation (SVEC) in Modoc County, California. BPA uses PacificCorp`s substation and transmission facilities between Alturas and Canby, California to transfer power to SVEC`s Canby Substation. In the next year, SVEC expects increased industrial, agricultural, and residential electric loads on their 69-kV transmission system south of Canby. SVEC`s substation can accommodate only about 10 percent of the expected additional electric load. BPA`s proposed action is intended to meet SVEC`s increasing electric load. BPA proposes to meet SVEC`s increasing energy load by tapping into BPA`s existing BPA Malin-Warner 230-kV transmission line, and building an 7.9-mile transmission line to a new BPA substation. BPA proposes to build the new substation next to the west side of SVEC`s Canby Substation (Figure 1). This new substation will allow SVEC to move the additional power over their existing transmission or distribution lines. This report is the environmental assessment of the potential impact of the proposed project. The assessment determined that no ``environmental impact statement`` is not required.

  16. Canby Area Service Project : Substation and Associated Transmission Line : Environmental Assessment.

    SciTech Connect

    United States. Bonneville Power Administration.

    1992-02-01

    Bonneville Power Administration (BPA) provides power to Surprise Valley Electrification Corporation (SVEC) in Modoc County, California. BPA uses PacificCorp's substation and transmission facilities between Alturas and Canby, California to transfer power to SVEC's Canby Substation. In the next year, SVEC expects increased industrial, agricultural, and residential electric loads on their 69-kV transmission system south of Canby. SVEC's substation can accommodate only about 10 percent of the expected additional electric load. BPA's proposed action is intended to meet SVEC's increasing electric load. BPA proposes to meet SVEC's increasing energy load by tapping into BPA's existing BPA Malin-Warner 230-kV transmission line, and building an 7.9-mile transmission line to a new BPA substation. BPA proposes to build the new substation next to the west side of SVEC's Canby Substation (Figure 1). This new substation will allow SVEC to move the additional power over their existing transmission or distribution lines. This report is the environmental assessment of the potential impact of the proposed project. The assessment determined that no environmental impact statement'' is not required.

  17. Coaxial tube array space transmission line characterization

    NASA Technical Reports Server (NTRS)

    Switzer, Colleen A.; Bents, David J.

    1987-01-01

    The coaxial tube array tether/transmission line used to connect an SP-100 nuclear power system to the space station was characterized over the range of reactor-to-platform separation distances of 1 to 10 km. Characterization was done with respect to array performance, physical dimensions and masses. Using a fixed design procedure, a family of designs was generated for the same power level (300 kWe), power loss (1.5 percent), and meteoroid survival probability (99.5 percent over 10 yr). To differentiate between vacuum insulated and gas insulated lines, two different maximum values of the E field were considered: 20 kV/cm (appropriate to vacuum insulation) and 50 kV/cm (compressed SF6). Core conductor, tube, bumper, standoff, spacer and bumper support dimensions, and masses were also calculated. The results of the characterization show mainly how transmission line size and mass scale with reactor-to-platform separation distance.

  18. Simulation study on transient electric shock characteristics of human body under high voltage ac transmission lines

    NASA Astrophysics Data System (ADS)

    Huang, Tao; Zou, Yanhui; Lv, Jianhong; Yang, Jinchun; Tao, Li; Zhou, Jianfei

    2017-09-01

    Human body under high-voltage AC transmission lines will produce a certain induced voltage due to the electrostatic induction. When the human body contacts with some grounded objects, the charges transfer from the body to the ground and produce contact current which may cause transient electric shock. Using CDEGS and ATP/EMTP, the paper proposes a method for quantitatively calculating the transient electric shock characteristics. It calculates the human body voltage, discharge current and discharge energy under certain 500kV compact-type transmission lines and predicts the corresponding human feelings. The results show that the average root value of discharge current is less than 10mA when the human body is under the 500kV compact-type transmission lines and the human body is overall safe if the transmission lines satisfy the relevant design specifications. It concludes that the electric field strength above the ground should be limited to 4kV/m through the residential area for the purpose of reducing the electromagnetic impact.

  19. Transmission line environmental assessment guidance document

    SciTech Connect

    Jackson, J.; Pentecost, E.; Muzzarelli, J.

    1994-01-01

    Since 1939, U.S. utility companies have been required to obtain a Presidential Permit to construct electric transmission lines that cross a U.S. border and connect with a foreign utility. The purpose of this document is to provide Presidential Permit applicants with two types of guidance: (1) on the type of environmental and project descriptive information needed to assess the potential impacts of the proposed and alternative actions and (2) on compliance with applicable federal and state regulations. The main three chapters present information on the purpose and content of this document (Chapter 1); legislative, regulatory, and consultation requirements for transmission line interconnect projects (Chapter 2); and identification of basic transmission system design parameters and environmental data requirements for analysis of potential impacts of the proposed action (Chapter 3). Chapter 3 also includes information on possible techniques or measures to mitigate impacts. Appendix A presents an overview of NEPA requirements and DOE`s implementing procedures. Appendix B summarizes information on legislation that may be applicable to transmission line projects proposed in Presidential Permit applications.

  20. 7 CFR 1726.77 - Substation and transmission line construction.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 11 2013-01-01 2013-01-01 false Substation and transmission line construction. 1726... and Transmission Facilities § 1726.77 Substation and transmission line construction. (a) Contract... substation and transmission line construction (including minor modifications or improvements), exclusive...

  1. 7 CFR 1726.77 - Substation and transmission line construction.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 11 2014-01-01 2014-01-01 false Substation and transmission line construction. 1726... and Transmission Facilities § 1726.77 Substation and transmission line construction. (a) Contract... substation and transmission line construction (including minor modifications or improvements), exclusive...

  2. 7 CFR 1726.77 - Substation and transmission line construction.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 11 2012-01-01 2012-01-01 false Substation and transmission line construction. 1726... and Transmission Facilities § 1726.77 Substation and transmission line construction. (a) Contract... substation and transmission line construction (including minor modifications or improvements), exclusive...

  3. 7 CFR 1726.77 - Substation and transmission line construction.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 11 2011-01-01 2011-01-01 false Substation and transmission line construction. 1726... and Transmission Facilities § 1726.77 Substation and transmission line construction. (a) Contract... substation and transmission line construction (including minor modifications or improvements), exclusive...

  4. Transmission line analysis of noncylindrical birdcage resonators.

    PubMed

    Vullo, T; Pascone, R; Mancuso, R; Zipagan, R; Cahill, P T

    1994-01-01

    Transmission line theory, validated for the standard cylindrical birdcage coil, has been employed for the analysis of a rectangular birdcage resonator which is useful for MR imaging of the hand. Due to lack of cylindrical symmetry in the rectangular coil, RF field uniformity was evaluated and found to be critically dependent upon the choice of column from which the coil was linearly driven. Effective L1 and L2 inductance elements were determined using known formulas for self and mutual inductance contributions, and compensation of the different inductance elements of the hand coil was performed to produce cylindrically symmetric birdcage current patterns. RF field mapping using the Biot-Savart law demonstrated a rectangular coil sensitivity 22% greater than a comparable cylindrical version. MR hand and wrist images were acquired using the rectangular birdcage coil. In addition, transmission line analysis was extended to other noncylindrical birdcage geometries.

  5. Application of composite insulators to transmission lines

    SciTech Connect

    Cherney, E.A.; Brown, R.L.; Karady, G.; Nicholls, J.L.; Orbeck, T.; Pargamin, L.

    1983-05-01

    The paper provides guidelines for the application of composite insulators to transmission lines. These guidelines are based on utility field experiences, results of research laboratory tests and manufacturers' recommendations. Discussed are interchangeability with porcelain and glass insulators, application in contaminated environments, material ageing, insulator icing, the use of grease, resistance to vandalism, temperature extremes, and the need for grading rings. Clarification is provided on the mechanical rating of composite insulators because there is not yet general agreement by various industry groups.

  6. ULTRA HIGH POWER TRANSMISSION LINE TECHNIQUES

    DTIC Science & Technology

    The ultra-high power transmission line techniques including both failure mechanisms and component design are discussed. Failures resulting from...a waveguide. In view of the many advantages of the low loss mode in circular waveguide for ultra-high power levels, a mode transducer and a two...percent of the peak power of a standard rectangular wave guide. Water cooling is provided for high average power operation. Analysis of mode sup pression

  7. Quality Assurance Plan for site electrical replacements at substation line item subproject: 69 KV Substation

    SciTech Connect

    Ohler, C.K.

    1991-05-21

    The 69 KV Substation Project is based on the recognized need to provide a continuous, reliable source of power and to improve the firm capacity of the electrical service to all production facilities at Mound. The project consists of the following major element: 69 KV Substation: (1) Install a 69 KV Substation and associated equipment with two parallel 18 MVA transformers. (2) Install duct bank as required and provide 15 KV feeder cable from new substation to existing Substation 95 for connection to Mound`s existing primary distribution system. (3) Install duct bank for underground routing of the 15 KV feeder cable from Manhole 5C to the existing power house cable pit. (4) Reconfigure existing Dayton Power and Light Co. 15 KV switchgear in P Building. The purpose of this Quality Assurance Plan (QA Plan) is to assure that the objectives of the United States Department of Energy (D.O.E.) and EG&G Mound Applied Technologies, Miamisburg, Ohio (Mound) are met for this non-weapons project relative to health and safety, protection of the environment, reliability and continuity of operations, and documentation of quality efforts. This QA Plan identifies the activities and responsibilities which are necessary in the design, procurement, fabrication, installation, and start up of this project in order to meet these objectives.

  8. A dielectric-filled magnetically insulated transmission line oscillator

    NASA Astrophysics Data System (ADS)

    Fan, Yu-Wei; Wang, Xiao-Yu; Zhong, Hui-Huang; Zhang, Jian-De

    2015-03-01

    A dielectric-filled magnetically insulated transmission line oscillator (DFMILO) is presented in this paper, which introduces a low-loss dielectric to fill its resonant cavities and thus improves its technical performances. The fundamental mode frequency of the DFMILO is derived and its dispersion curve is analyzed. In simulation, high-power microwave is generated from the DFMILO with peak power of 3.1 GW, frequency of 1.467 GHz, and peak power conversion efficiency of 14.0% when the voltage is 455 kV and the current is 48.7 kA. However, the peak power conversion efficiency of the relevant unfilled MILO is only 8.5%. The comparative result shows that the filled dielectric helps to enhance the power conversion efficiency of the DFMILO. In addition, the filled dielectric contributes to decrease the MILO's dominant frequency, which means that if the dominant frequency is same, the volume of the DFMILO (especially the low-frequency DFMILO) is more compact than that of the relevant unfilled MILO.

  9. An improved X-band magnetically insulated transmission line oscillator

    NASA Astrophysics Data System (ADS)

    Ju, Jin-Chuan; Fan, Yu-Wei; Zhong, Hui-Huang; Shu, Ting

    2009-07-01

    This paper presents an improved X-band magnetically insulated transmission line oscillator (MILO) design that addresses several deficiencies found in previous experiments. In the new structure, an improved design of the launch point region is introduced, which improves the electric field uniformity on the cathode surface in order to suppress cathode flare formation. In addition, a new design for the load region is presented where the end of the cathode consists of four polymer velvet rings, a mesh is adopted as the anode of the load, and a metal barrel is employed as the beam dump. These improvements reduce energy deposition in the beam dump to less than 30 J/g, which probably suppresses plasma formation in the load region. Typical simulation results of the improved MILO show that when the applied voltage is 690 kV and beam current is 48 kA, high power microwave with an average power of 3.5 GW and a frequency of 9.26 GHz is generated. Furthermore, new meshes are specially studied for long pulse operation of this improved X-band MILO. Correlative experiments are being carried out in our laboratory.

  10. Dispersion-free radial transmission lines

    DOEpatents

    Caporaso, George J [Livermore, CA; Nelson, Scott D [Patterson, CA

    2011-04-12

    A dispersion-free radial transmission line ("DFRTL") preferably for linear accelerators, having two plane conductors each with a central hole, and an electromagnetically permeable material ("EPM") between the two conductors and surrounding a channel connecting the two holes. At least one of the material parameters of relative magnetic permeability, relative dielectric permittivity, and axial width of the EPM is varied as a function of radius, so that the characteristic impedance of the DFRTL is held substantially constant, and pulse transmission therethrough is substantially dispersion-free. Preferably, the EPM is divided into concentric radial sections, with the varied material parameters held constant in each respective section but stepwise varied between sections as a step function of the radius. The radial widths of the concentric sections are selected so that pulse traversal time across each section is the same, and the varied material parameters of the concentric sections are selected to minimize traversal error.

  11. View facing north, Structure 162 in foreground, as Transmission Line ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View facing north, Structure 16-2 in foreground, as Transmission Line turns at intersection of Powerline Road and US 87 - Havre Rainbow Transmission Line, Havre City to Great Falls vicinity, Montana, Great Falls, Cascade County, MT

  12. View facing south, near Structure 515, of Transmission Line rising ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View facing south, near Structure 51-5, of Transmission Line rising out of Marias River Valley - Havre Rainbow Transmission Line, Havre City to Great Falls vicinity, Montana, Great Falls, Cascade County, MT

  13. 3. DETAIL, LIGHTNING ARRESTER ON SAR TRANSMISSION LINE. EEC print ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. DETAIL, LIGHTNING ARRESTER ON SAR TRANSMISSION LINE. EEC print no. S-C-01-00478, no date. Photographer unknown. - Santa Ana River Hydroelectric System, Transmission Lines, Redlands, San Bernardino County, CA

  14. Experimental research on Ku-band magnetically insulated transmission line oscillator

    NASA Astrophysics Data System (ADS)

    Jiang, Tao; Zhang, Jiande; He, Juntao; Li, Zhiqiang; Ling, Junpu

    2015-10-01

    An improved Ku-band magnetically insulated transmission line oscillator is proposed and investigated experimentally. In the particle-in-cell simulation, the Ku-band MILO generates the microwave with a power of 1.62 GW and a frequency of 13 GHz at the input voltage of 474 kV. The device is fabricated based on the simulation results, and an experiment system is designed. In the preliminary experiments, output microwave with frequency of 13.02 GHz, power of 150 MW, and pulse width of 17 ns is generated, under the diode voltage of 450 kV. Analysis on the experiment results shows that plasma produced due to the large current hitting to the outside of the collection tank is the essential cause for the low amplitude of the microwave power and short pulse width.

  15. Transmission line including support means with barriers

    DOEpatents

    Cookson, Alan H.

    1982-01-01

    A gas insulated transmission line includes an elongated outer sheath, a plurality of inner conductors disposed within and extending along the outer sheath, and an insulating gas which electrically insulates the inner conductors from the outer sheath. A support insulator insulatably supports the inner conductors within the outer sheath, with the support insulator comprising a main body portion including a plurality of legs extending to the outer sheath, and barrier portions which extend between the legs. The barrier portions have openings therein adjacent the main body portion through which the inner conductors extend.

  16. Transmission line icing measurement on photogrammetry method

    NASA Astrophysics Data System (ADS)

    Huang, Huan; Ma, Xiaohong; Zhao, Lijin; Du, Hao; Luo, Hong; Mao, Xianyin; Tang, Min; Liu, Yawen

    2015-12-01

    Icing thickness parameter is the basic data for power sector to make decision for icing accident prevention. In this paper, a transmission line icing measurement method is proposed. It used the photogrammetry method to realize icing parameters measurement through the integration of high resolution camera, laser range finder and inertial measurement unit. Compared with traditional icing measurement method, this method is flexible and is the effective supplement of the fixed icing detection terminal. And its high accuracy measurement guarantees the reliability of the icing thickness parameters.

  17. Design of a 300-kV gas environmental transmission electron microscope equipped with a cold field emission gun.

    PubMed

    Isakozawa, Shigeto; Nagaoki, Isao; Watabe, Akira; Nagakubo, Yasuhira; Saito, Nobuhiro; Matsumoto, Hiroaki; Zhang, Xiao Feng; Taniguchi, Yoshifumi; Baba, Norio

    2016-08-01

    A new in situ environmental transmission electron microscope (ETEM) was developed based on a 300 kV TEM with a cold field emission gun (CFEG). Particular caution was taken in the ETEM design to assure uncompromised imaging and analytical performance of the TEM. Because of the improved pumping system between the gun and column, the vacuum of CFEG was largely improved and the probe current was sufficiently stabilized to operate without tip flashing for 2-3 h or longer. A high brightness of 2.5 × 10(9) A/cm(2) sr was measured at 300 kV, verifying the high quality of the CFEG electron beam. A specially designed gas injection-heating holder was used in the in situ TEM study at elevated temperatures with or without gas around the TEM specimen. Using this holder in a 10 Pa gas atmosphere and specimen temperatures up to 1000°C, high-resolution ETEM performance and analysis were achieved.

  18. Multi-transmission-line-beam interactive system

    SciTech Connect

    Figotin, Alexander; Reyes, Guillermo

    2013-11-15

    We construct here a Lagrangian field formulation for a system consisting of an electron beam interacting with a slow-wave structure modeled by a possibly non-uniform multiple transmission line (MTL). In the case of a single line we recover the linear model of a traveling wave tube due to J. R. Pierce. Since a properly chosen MTL can approximate a real waveguide structure with any desired accuracy, the proposed model can be used in particular for design optimization. Furthermore, the Lagrangian formulation provides: (i) a clear identification of the mathematical source of amplification, (ii) exact expressions for the conserved energy and its flux distributions obtained from the Noether theorem. In the case of uniform MTLs we carry out an exhaustive analysis of eigenmodes and find sharp conditions on the parameters of the system to provide for amplifying regimes.

  19. Giant vacuum forces via transmission lines

    PubMed Central

    Shahmoon, Ephraim; Mazets, Igor; Kurizki, Gershon

    2014-01-01

    Quantum electromagnetic fluctuations induce forces between neutral particles, known as the van der Waals and Casimir interactions. These fundamental forces, mediated by virtual photons from the vacuum, play an important role in basic physics and chemistry and in emerging technologies involving, e.g., microelectromechanical systems or quantum information processing. Here we show that these interactions can be enhanced by many orders of magnitude upon changing the character of the mediating vacuum modes. By considering two polarizable particles in the vicinity of any standard electric transmission line, along which photons can propagate in one dimension, we find a much stronger and longer-range interaction than in free space. This enhancement may have profound implications on many-particle and bulk systems and impact the quantum technologies mentioned above. The predicted giant vacuum force is estimated to be measurable in a coplanar waveguide line. PMID:25002503

  20. Giant vacuum forces via transmission lines

    NASA Astrophysics Data System (ADS)

    Shahmoon, Ephraim; Mazets, Igor; Kurizki, Gershon

    2015-03-01

    Quantum electromagnetic fluctuations induce forces between neutral particles, namely, the van der Waals (vdW) and Casimir interactions. Here we show that these fundamental interactions can be enhanced by many orders of magnitude upon changing the character of the mediating vacuum photon-modes. We consider two dipoles in the vicinity of any standard electric transmission line and find analytically that the interaction scales non-trivially with the inter-dipolar distance, resulting in a strong and long-range interaction. This may have profound implications on the non-additivity of vdW and Casimir interactions in many-particle systems, and opens the door for Casimir Physics in 1d. We discuss the possibilities of measuring this effect, e.g. in a coplanar waveguide line. In January 2015, my affiliation is supposed to change to ``Department of Physics, Harvard University.''

  1. SMILE transmission line adder for RADLAC II

    SciTech Connect

    Mazarakis, M.G.; Poukey, J.W.; Shope, S.L.; Frost, C.A.; Turman, B.N.; Ramirez, J.J.; Prestwich, K.R.; Pankuch, P.J.

    1991-12-31

    SMILE is a coaxial Self Magnetically Insulated Transmission Line voltage adder. It replaces the original beam line of the RADLAC II accelerator by a 12.5 m long cathode electrode. The anode electrode remains practically the same, consisting of the original eight insulating stacks or feeds which are connected with equal diameter stainless steel cylinders. The beam is produced at the end of the accelerator and is free of all the possible instabilities associated with accelerating gaps and magnetic vacuum transport. Annular beams with {beta}{perpendicular} {le} 0.1 and radius r{sub b} {le} 1 cm were routinely obtained and extracted from a small magnetically-immersed foilless electron diode. Results of the experimental evaluation are presented and compared with design parameters and numerical simulation predictions. 4 refs.

  2. SMILE transmission line adder for RADLAC II

    SciTech Connect

    Mazarakis, M.G.; Poukey, J.W.; Shope, S.L.; Frost, C.A.; Turman, B.N.; Ramirez, J.J.; Prestwich, K.R. ); Pankuch, P.J. . Special Projects)

    1991-01-01

    SMILE is a coaxial Self Magnetically Insulated Transmission Line voltage adder. It replaces the original beam line of the RADLAC II accelerator by a 12.5 m long cathode electrode. The anode electrode remains practically the same, consisting of the original eight insulating stacks or feeds which are connected with equal diameter stainless steel cylinders. The beam is produced at the end of the accelerator and is free of all the possible instabilities associated with accelerating gaps and magnetic vacuum transport. Annular beams with {beta}{perpendicular} {le} 0.1 and radius r{sub b} {le} 1 cm were routinely obtained and extracted from a small magnetically-immersed foilless electron diode. Results of the experimental evaluation are presented and compared with design parameters and numerical simulation predictions. 4 refs.

  3. 49 CFR 192.179 - Transmission line valves.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Transmission line valves. 192.179 Section 192.179... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Design of Pipeline Components § 192.179 Transmission line valves. (a) Each transmission line, other than offshore segments, must have sectionalizing...

  4. 49 CFR 192.719 - Transmission lines: Testing of repairs.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Transmission lines: Testing of repairs. 192.719 Section 192.719 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... Transmission lines: Testing of repairs. (a) Testing of replacement pipe. If a segment of transmission line...

  5. 49 CFR 192.719 - Transmission lines: Testing of repairs.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Transmission lines: Testing of repairs. 192.719 Section 192.719 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... Transmission lines: Testing of repairs. (a) Testing of replacement pipe. If a segment of transmission line...

  6. 49 CFR 192.745 - Valve maintenance: Transmission lines.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Valve maintenance: Transmission lines. 192.745 Section 192.745 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... maintenance: Transmission lines. (a) Each transmission line valve that might be required during any...

  7. 49 CFR 192.719 - Transmission lines: Testing of repairs.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Transmission lines: Testing of repairs. 192.719 Section 192.719 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... Transmission lines: Testing of repairs. (a) Testing of replacement pipe. If a segment of transmission line...

  8. 49 CFR 192.745 - Valve maintenance: Transmission lines.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Valve maintenance: Transmission lines. 192.745 Section 192.745 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... maintenance: Transmission lines. (a) Each transmission line valve that might be required during any...

  9. 49 CFR 192.719 - Transmission lines: Testing of repairs.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Transmission lines: Testing of repairs. 192.719 Section 192.719 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... Transmission lines: Testing of repairs. (a) Testing of replacement pipe. If a segment of transmission line...

  10. 49 CFR 192.179 - Transmission line valves.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Transmission line valves. 192.179 Section 192.179... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Design of Pipeline Components § 192.179 Transmission line valves. (a) Each transmission line, other than offshore segments, must have sectionalizing...

  11. 49 CFR 192.745 - Valve maintenance: Transmission lines.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Valve maintenance: Transmission lines. 192.745 Section 192.745 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... maintenance: Transmission lines. (a) Each transmission line valve that might be required during any...

  12. 49 CFR 192.745 - Valve maintenance: Transmission lines.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Valve maintenance: Transmission lines. 192.745 Section 192.745 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... maintenance: Transmission lines. (a) Each transmission line valve that might be required during any...

  13. 49 CFR 192.706 - Transmission lines: Leakage surveys.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Transmission lines: Leakage surveys. 192.706... Transmission lines: Leakage surveys. Leakage surveys of a transmission line must be conducted at intervals not... transports gas in conformity with § 192.625 without an odor or odorant, leakage surveys using leak...

  14. 49 CFR 192.706 - Transmission lines: Leakage surveys.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Transmission lines: Leakage surveys. 192.706... Transmission lines: Leakage surveys. Leakage surveys of a transmission line must be conducted at intervals not... transports gas in conformity with § 192.625 without an odor or odorant, leakage surveys using leak...

  15. 49 CFR 192.706 - Transmission lines: Leakage surveys.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Leakage surveys. 192.706... Transmission lines: Leakage surveys. Leakage surveys of a transmission line must be conducted at intervals not... transports gas in conformity with § 192.625 without an odor or odorant, leakage surveys using leak...

  16. 49 CFR 192.706 - Transmission lines: Leakage surveys.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Transmission lines: Leakage surveys. 192.706... Transmission lines: Leakage surveys. Leakage surveys of a transmission line must be conducted at intervals not... transports gas in conformity with § 192.625 without an odor or odorant, leakage surveys using leak...

  17. 49 CFR 192.745 - Valve maintenance: Transmission lines.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valve maintenance: Transmission lines. 192.745... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.745 Valve maintenance: Transmission lines. (a) Each transmission line valve that might be required during any emergency...

  18. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 4 2013-07-01 2013-07-01 false Power transmission lines. 644.431 Section 644... Power transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus... power transmission line and the right of way acquired for its construction is needed for or adaptable to...

  19. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 4 2011-07-01 2011-07-01 false Power transmission lines. 644.431 Section 644... Power transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus... power transmission line and the right of way acquired for its construction is needed for or adaptable to...

  20. Microstrip transmission line tapers on ferrites

    SciTech Connect

    Albuquerque, M.R.; dAssuncao, A.G.; Lima, F.

    1997-04-01

    The spectral domain approach is employed to perform a theoretical investigation of tapered microstrip lines on magnetized ferrite substrates. A linear variation of the conducting strip width along the direction of propagation is considered. The analysis takes into account the effects of the applied dc magnetic bias field in the transmission characteristics of these structures. The properties of the taper are determined by a model based on a segmentation of the considered line into uniform microstrip line subsections. Normalized phase constants and characteristic impedances are obtained by using the Hertz vector potentials method and Galerkin numerical technique. Numerical results are presented to show the taper input parameters as a function of the load impedance, geometrical dimensions, operating frequency, and ferrite parameters, considering the orientation and magnitude changes of the biasing magnetic-field {bold H}{sub 0}. The results agree fairly well with those available in the literature for tapered microstrip lines on isotropic dielectric substrates. {copyright} {ital 1997 American Institute of Physics.}

  1. Overview of RyantoRainbow Line 1 (foreground) and Line 2 (center) ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Overview of Ryan-to-Rainbow Line 1 (foreground) and Line 2 (center) in context with Morony-to-Rainbow 100kv Transmission Line (background) about on-half mile southwest of Ryan Dam. View to north - Ryan Hydroelectric Facility, Ryan-to-Rainbow 100 kV Transmission Line, West bank of Missouri River, northeast of Great Falls, Great Falls, Cascade County, MT

  2. A radial transmission line material measurement apparatus

    SciTech Connect

    Warne, L.K.; Moyer, R.D.; Koontz, T.E.; Morris, M.E.

    1993-05-01

    A radial transmission line material measurement sample apparatus (sample holder, offset short standards, measurement software, and instrumentation) is described which has been proposed, analyzed, designed, constructed, and tested. The purpose of the apparatus is to obtain accurate surface impedance measurements of lossy, possibly anisotropic, samples at low and intermediate frequencies (vhf and low uhf). The samples typically take the form of sections of the material coatings on conducting objects. Such measurements thus provide the key input data for predictive numerical scattering codes. Prediction of the sample surface impedance from the coaxial input impedance measurement is carried out by two techniques. The first is an analytical model for the coaxial-to-radial transmission line junction. The second is an empirical determination of the bilinear transformation model of the junction by the measurement of three full standards. The standards take the form of three offset shorts (and an additional lossy Salisbury load), which have also been constructed. The accuracy achievable with the device appears to be near one percent.

  3. Modeling Transmission Line Networks Using Quantum Graphs

    NASA Astrophysics Data System (ADS)

    Koch, Trystan; Antonsen, Thomas

    Quantum graphs--one dimensional edges, connecting nodes, that support propagating Schrödinger wavefunctions--have been studied extensively as tractable models of wave chaotic behavior (Smilansky and Gnutzmann 2006, Berkolaiko and Kuchment 2013). Here we consider the electrical analog, in which the graph represents an electrical network where the edges are transmission lines (Hul et. al. 2004) and the nodes contain either discrete circuit elements or intricate circuit elements best represented by arbitrary scattering matrices. Including these extra degrees of freedom at the nodes leads to phenomena that do not arise in simpler graph models. We investigate the properties of eigenfrequencies and eigenfunctions on these graphs, and relate these to the statistical description of voltages on the transmission lines when driving the network externally. The study of electromagnetic compatibility, the effect of external radiation on complicated systems with numerous interconnected cables, motivates our research into this extension of the graph model. Work supported by the Office of Naval Research (N0014130474) and the Air Force Office of Scientific Research.

  4. Effects of high-voltage transmission lines on honeybees

    SciTech Connect

    Greenberg, B.; Bindokas, V.P.; Gauger, J.R.

    1985-05-01

    When shielded and exposed colonies were placed at incremental distances at a right angle from a 760-kV transmission line different thresholds for biologic effects were obtained. Hive exposures were controlled (E-field: 7, 5.5, 4.1, 1.8, and 0.65 to 0.85 kV/m) by variable height current collectors; shielded hives under the line behave normally. Exposure to 7 kV/m can produce the following sequence of events: (1) increased motor activity and transient hive temperature increase; (2) abnormal propolization; (3) retarded hive weight gain; (4) excess queen cell production with queen loss; (5) reduction of sealed brood area; and (6) poor winter survival. No biological effects were detected below 4.1 kV/m, thus the ''biological effects corridor'' is limited to approximately 23 m beyond a ground projection of each outer phase wire. Hive architecture enhances E-fields and creates shock hazards for bees. Intra-hive E-fields (15 to 100+ kV/m) were measured with a displacement current sensor and fiber optic telemetry link. Step-potential-induced currents up to 0.5 uA were measured with a bee model in hives at 7 kV/m. To investigate further the role of shock versus electric field exposure the study was continued to develop hive entrance extensions (porches), which produce controlled bee exposure to E-field or shock, and to test the feasibility of using these porches in such a study. Biological effects (e.g., abnormal propolization, retarded hive weight, queen loss) found in colonies with total-hive exposure were produced by entrance-only exposure of adult bees. We now have an exposure system in which E-field and shock can be separately controlled to reproduce the biological effects. 10 refs.

  5. Method for bonding a transmission line to a downhole tool

    DOEpatents

    Hall, David R.; Fox, Joe

    2007-11-06

    An apparatus for bonding a transmission line to the central bore of a downhole tool includes a pre-formed interface for bonding a transmission line to the inside diameter of a downhole tool. The pre-formed interface includes a first surface that substantially conforms to the outside contour of a transmission line and a second surface that substantially conforms to the inside diameter of a downhole tool. In another aspect of the invention, a method for bonding a transmission line to the inside diameter of a downhole tool includes positioning a transmission line near the inside wall of a downhole tool and placing a mold near the transmission line and the inside wall. The method further includes injecting a bonding material into the mold and curing the bonding material such that the bonding material bonds the transmission line to the inside wall.

  6. Electrical characteristics of sea-water-return transmission lines

    NASA Astrophysics Data System (ADS)

    Gholson, N.; Swenson, R.; Alexander, C.

    1982-08-01

    An experiment was conducted at sea to determine characteristics of three single copper conductor transmission lines. All three transmission lines incorporated seawater as an electrical return path and graphite shielding of various constructions in an attempt to achieve desirable characteristics of coaxial transmission lines. The transmission lines were 20,000 feet long, 0.1 inches in diameter, and used braided Kevlar at a strength member. The primary problem addresses was measuring low frequency (<20kHz) attenuation and phase shift of the transmission lines as a function of configuration in the water column and as a function of graphite shield construction. Results show that transmission line electrical characteristics as much better when the line is fully payed out as opposed to part of the line being coiled.

  7. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-130- Keeler-Tillamook)

    SciTech Connect

    Sherer, Brett M.

    2003-03-10

    Vegetation Management for the Keeler Tillamook 115 kV transmission line from structure 1/7 through structure 58/2, and along adjacent portions of the Keeler-Forest Grove #2 115KV transmission line. In addition the project includes 11miles of the 115KV Timber Tap.

  8. Transmission line matrix model for ultrasonic imaging

    NASA Astrophysics Data System (ADS)

    Ciocan, Razvan; Ida, Nathan; Driscoll, Diana

    2002-06-01

    A transmission-line matrix (TLM) model was developed to simulate the ultrasound propagation in the multi-layer structures. The spatial resolution of the proposed model is better than tenth wavelength. The numerical modeling is carried-out for frequencies that are usually used in ultrasound imagery (3.5 - 25MHz). The acoustic impedance profile of multi-layer structures considered are similar to those found in nondestructive evaluation and in medical imaging. The structures modeled are: brazed joints, stomach and colon walls. Structures with artificial flaws are also modeled. A comparison between real images and numerical generated ones is provided for each considered structure. Both frequency and time domain responses are obtained from the structures under investigation. Both single and array transducer techniques are modeled and their performances are evaluated for the proposed structures. Different shapes for the incident pulse are considered in numerically generated images.

  9. Complex magnetically insulated transmission line oscillator

    SciTech Connect

    Fan Yuwei; Zhong Huihuang; Shu Ting; Li Zhiqiang

    2008-08-15

    A magnetically insulated transmission line oscillator (MILO) is a crossed-field device designed specifically to generate microwave power at the gigawatt level, which is a major hotspot in the field of high-power microwaves (HPM) research at present. It is one of the major thrust for MILO development to improve the power conversion efficiency. In order to improve the power conversion efficiency of MILO, a complex MILO is presented and investigated theoretically and numerically, which comprises the MILO-1 and MILO-2. The MILO-2 is used as the load of the MILO-1. The theoretical analyses show that the maximum power conversion efficiency of the complex MILO has an increase of about 50% over the conventional load-limited MILO. The complex MILO is optimized with KARAT code (V. P. Tarakanov, Berkeley Research Associates, Inc., 1992), and the simulation results agree with the theoretical results.

  10. Nonlinear transmission line based electron beam driver

    SciTech Connect

    French, David M.; Hoff, Brad W.; Tang Wilkin; Heidger, Susan; Shiffler, Don; Allen-Flowers, Jordan

    2012-12-15

    Gated field emission cathodes can provide short electron pulses without the requirement of laser systems or cathode heating required by photoemission or thermionic cathodes. The large electric field requirement for field emission to take place can be achieved by using a high aspect ratio cathode with a large field enhancement factor which reduces the voltage requirement for emission. In this paper, a cathode gate driver based on the output pulse train from a nonlinear transmission line is experimentally demonstrated. The application of the pulse train to a tufted carbon fiber field emission cathode generates short electron pulses. The pulses are approximately 2 ns in duration with emission currents of several mA, and the train contains up to 6 pulses at a frequency of 100 MHz. Particle-in-cell simulation is used to predict the characteristic of the current pulse train generated from a single carbon fiber field emission cathode using the same technique.

  11. Predicting the impacts of a high-voltage transmission line on big game hunting opportunities in Western Montana

    Treesearch

    Stewart Allen

    1985-01-01

    The State of Montana, in cooperation with the U.S. Forest Service and Bonneville Power Administration, is conducting a five-vear study on the impacts of a 500-kV transmission line on elk habitat and hunter opportunity. In fall 1983, baseline data on hunting patterns and quality were collected from over 600 hunters interviewed in three western Montana study areas. A...

  12. 7 CFR 1726.77 - Substation and transmission line construction.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 11 2010-01-01 2010-01-01 false Substation and transmission line construction. 1726... UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE ELECTRIC SYSTEM CONSTRUCTION POLICIES AND PROCEDURES Substation and Transmission Facilities § 1726.77 Substation and transmission line construction. (a) Contract...

  13. 49 CFR 192.705 - Transmission lines: Patrolling.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Transmission lines: Patrolling. 192.705 Section... NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.705 Transmission... adjacent to the transmission line right-of-way for indications of leaks, construction activity, and...

  14. 49 CFR 192.709 - Transmission lines: Record keeping.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Transmission lines: Record keeping. 192.709 Section 192.709 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... Transmission lines: Record keeping. Each operator shall maintain the following records for transmission...

  15. 49 CFR 192.705 - Transmission lines: Patrolling.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Transmission lines: Patrolling. 192.705 Section... NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.705 Transmission... adjacent to the transmission line right-of-way for indications of leaks, construction activity, and...

  16. 49 CFR 192.705 - Transmission lines: Patrolling.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Transmission lines: Patrolling. 192.705 Section... NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.705 Transmission... adjacent to the transmission line right-of-way for indications of leaks, construction activity, and...

  17. 49 CFR 192.705 - Transmission lines: Patrolling.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Patrolling. 192.705 Section... NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.705 Transmission... adjacent to the transmission line right-of-way for indications of leaks, construction activity, and...

  18. 49 CFR 192.709 - Transmission lines: Record keeping.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Transmission lines: Record keeping. 192.709 Section 192.709 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... Transmission lines: Record keeping. Each operator shall maintain the following records for transmission...

  19. 49 CFR 192.709 - Transmission lines: Record keeping.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Transmission lines: Record keeping. 192.709 Section 192.709 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... Transmission lines: Record keeping. Each operator shall maintain the following records for transmission...

  20. 49 CFR 192.705 - Transmission lines: Patrolling.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Transmission lines: Patrolling. 192.705 Section... NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.705 Transmission... adjacent to the transmission line right-of-way for indications of leaks, construction activity, and...

  1. 49 CFR 192.709 - Transmission lines: Record keeping.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Transmission lines: Record keeping. 192.709 Section 192.709 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... Transmission lines: Record keeping. Each operator shall maintain the following records for transmission...

  2. Big Creek Hydroelectric System, East & West Transmission Line, 241mile ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Big Creek Hydroelectric System, East & West Transmission Line, 241-mile transmission corridor extending between the Big Creek Hydroelectric System in the Sierra National Forest in Fresno County and the Eagle Rock Substation in Los Angeles, California, Visalia, Tulare County, CA

  3. HEM11 mode magnetically insulated transmission line oscillator: Simulation and experiment

    NASA Astrophysics Data System (ADS)

    Wang, Dong; Qin, Fen; Wen, Jie; Chen, Dai-Bing; Jin, Xiao; An, Hai-Shi; Zhang, Xin-Kai

    2012-08-01

    A novel magnetically insulated transmission line oscillator (MILO) in which a modified HEM11 mode is taken as its main interaction mode (HEM11 mode MILO) is simulated and experimented in this paper. The excitation of the oscillation mode is made possible by carefully adjusting the arrangement of each resonant cavity in a two-dimensional slow wave structure. The special feature of such a device is that in the slow-wave-structure region, the interaction mode is HEM11 mode which is a TM-like one that could interact with electron beams effectively; and in the coaxial output region, the microwave mode is TE11 mode which has a favourable field density pattern to be directly radiated. Employing an electron beam of about 441 kV and 39.7 kA, the HEM11 mode MILO generates a high power microwave output of about 1.47 GW at 1.45 GHz in particle-in-cell simulation. The power conversion efficiency is about 8.4 % and the generated microwave is in a TE11-like circular polarization mode. In a preliminary experiment investigation, high power microwave is detected from the device with a frequency of 1.46 GHz, an output energy of 43 J-47 J, and a pulse duration of 44 ns-49 ns when the input voltage is 430 kV-450 kV, and the diode current is 37 kA-39 kA.

  4. Four channel high power rf source with beam steering based on gyromagnetic nonlinear transmission lines

    NASA Astrophysics Data System (ADS)

    Romanchenko, I. V.; Ulmaskulov, M. R.; Sharypov, K. A.; Shunailov, S. A.; Shpak, V. G.; Yalandin, M. I.; Pedos, M. S.; Rukin, S. N.; Konev, V. Yu.; Rostov, V. V.

    2017-05-01

    The synchronized operation of four gyromagnetic nonlinear transmission lines (NLTLs) was tested with a pulse repetition frequency up to 1 kHz during 1 s bursts. High voltage pulses with a duration of ˜5 ns from the solid state driver S-500 were split into four 48 Ω channels reaching about -200 kV in each channel with ˜10% variation in the amplitude. The maximum peak voltage at the NLTL output was within 220-235 kV with the maximum modulation depth of decaying oscillations up to 90% at the center frequency near 2.1 GHz. The relative delay between channels reached the half-period of the center frequency of oscillations. The associated beam steering by four element array of conical helical antennas was demonstrated in a horizontal plane at 17°. The effective potential of radiation reached 360 kV at the radiation axis. The effect of ferrite temperature on the shock wave velocity in gyromagnetic NLTL is observed.

  5. Four channel high power rf source with beam steering based on gyromagnetic nonlinear transmission lines.

    PubMed

    Romanchenko, I V; Ulmaskulov, M R; Sharypov, K A; Shunailov, S A; Shpak, V G; Yalandin, M I; Pedos, M S; Rukin, S N; Konev, V Yu; Rostov, V V

    2017-05-01

    The synchronized operation of four gyromagnetic nonlinear transmission lines (NLTLs) was tested with a pulse repetition frequency up to 1 kHz during 1 s bursts. High voltage pulses with a duration of ∼5 ns from the solid state driver S-500 were split into four 48 Ω channels reaching about -200 kV in each channel with ∼10% variation in the amplitude. The maximum peak voltage at the NLTL output was within 220-235 kV with the maximum modulation depth of decaying oscillations up to 90% at the center frequency near 2.1 GHz. The relative delay between channels reached the half-period of the center frequency of oscillations. The associated beam steering by four element array of conical helical antennas was demonstrated in a horizontal plane at 17°. The effective potential of radiation reached 360 kV at the radiation axis. The effect of ferrite temperature on the shock wave velocity in gyromagnetic NLTL is observed.

  6. Radio frequency communication system utilizing radiating transmission lines

    DOEpatents

    Struven, Warren C.

    1984-01-01

    A radio communication system for use in tunnels, mines, buildings or other shielded locations in which a pair of radiating transmission lines (30), (31) extend through such location in spaced coextensive relation to each other. Each transmission line (30), (31) has at least one unidirectional amplifier (32), (33) interposed therein with the sense of the unidirectional amplifier (32) of one transmission line (30) being opposite to the sense of the unidirectional amplifier (33) of the other transmission line (31). Each of the amplifiers (32), (33) has a gain which is less than the coupling loss between the transmission lines (30), (31). Two or more mobile transceivers (35) in the location served by the system are coupled to the transmission lines (30), (31) by electromagnetic wave propagation in space in order to communicate directly with each other at a given radio frequency within the frequency range of the system.

  7. Bonneville upgrades lines

    SciTech Connect

    Not Available

    1993-08-30

    A stretch of Bonneville Power Administration transmission line between Spokane and the Grand Coulee Dam is an 82-mile bottleneck as it is the last 115-kv section of [open quotes]road[close quotes] along a 500-kv transmission [open quotes]highway[close quotes]. Soon the administration will change all that. A number of independent and utility powerplants have been proposed in Idaho, Montana and the Spokane, Wash., area during the 1990s. As the operators will need to move their power, Bonneville is planning to build a $144-million, 500-kv line to upgrade the 115-kv section. The agency is planning to use its existing right-of-way.

  8. Experiments of a monolithic radial transmission line

    NASA Astrophysics Data System (ADS)

    Mao, C.; Wang, X.; Zou, X.; Lehr, J.

    2016-11-01

    This paper presents the experimental results of a monolithic radial transmission line (MRTL) that may be used in pulsed power generators and microwave devices. The MRTL with a hyperbolic impedance profile is 508 mm in radius, corresponding to a one-way transit time of 15 ns for the electromagnetic wave. In the experiments, up to twenty identical voltage pulses, 10 ns in FWHM and 2 ns in rise-time, were fed into the MRTL through 20 input BNC connectors that are uniformly distributed along the outer circumference of the MRTL. It was found that the amplitude of the voltage from the output BNC connector located in the center of the MRTL is nearly proportional to the total number of the input branches. The effect of the failure modes on the output voltage was investigated. For the MRTL driven by 20 input branches, while the open-circuit or short-circuit even in one input branch considerably decreases the amplitude of the output voltage, the jitter shorter than 2 ns in 3 input branches makes no obvious effect on the output voltage.

  9. Experiments of a monolithic radial transmission line.

    PubMed

    Mao, C; Wang, X; Zou, X; Lehr, J

    2016-11-01

    This paper presents the experimental results of a monolithic radial transmission line (MRTL) that may be used in pulsed power generators and microwave devices. The MRTL with a hyperbolic impedance profile is 508 mm in radius, corresponding to a one-way transit time of 15 ns for the electromagnetic wave. In the experiments, up to twenty identical voltage pulses, 10 ns in FWHM and 2 ns in rise-time, were fed into the MRTL through 20 input BNC connectors that are uniformly distributed along the outer circumference of the MRTL. It was found that the amplitude of the voltage from the output BNC connector located in the center of the MRTL is nearly proportional to the total number of the input branches. The effect of the failure modes on the output voltage was investigated. For the MRTL driven by 20 input branches, while the open-circuit or short-circuit even in one input branch considerably decreases the amplitude of the output voltage, the jitter shorter than 2 ns in 3 input branches makes no obvious effect on the output voltage.

  10. Flux Noise in a Superconducting Transmission Line

    NASA Astrophysics Data System (ADS)

    Vasko, F. T.

    2017-08-01

    We study a superconducting transmission line (TL) formed by distributed L C oscillators and excited by external magnetic fluxes which are aroused from random magnetization (A ) placed in substrate or (B ) distributed at interfaces of a two-wire TL. The low-frequency dynamics of a random magnetic field is described based on the diffusion Langevin equation with a short-range source caused by (a ) a random amplitude or (b ) the gradient of magnetization. For a TL modeled as a two-port network with open and shorted ends, the effective magnetic flux at the open end has nonlocal dependency on noise distribution along the TL. The flux-flux correlation function is evaluated and analyzed for the regimes (A a ), (A b ), (B a ), and (B b ). Essential frequency dispersion takes place around the inverse diffusion time of random flux along the TL. Typically, noise effect increases with size faster than the area of the TL. The flux-flux correlator can be verified both via the population relaxation rate of the qubit, which is formed by the Josephson junction shunted by the TL with flux noises, and via random voltage at the open end of the TL.

  11. Tucson Electric Power Company Sahuarita-Nogales Transmission Line Draft Environmental Impact Statement

    SciTech Connect

    N /A

    2003-08-27

    Tucson Electric Power Company (TEP) has applied to the U.S. Department of Energy (DOE) for a Presidential Permit to construct and operate a double-circuit, 345,000-volt (345-kV) electric transmission line across the United States border with Mexico. Under Executive Order (EO) 10485 of September 3, 1953, as amended by EO 12038 of February 3, 1978, a Presidential Permit is required to construct, connect, operate, or maintain facilities at the U.S. international border for the transmission of electric energy between the United States and a foreign country. DOE has determined that the issuance of a Presidential Permit to TEP for the proposed project would constitute a major Federal action that may have a significant impact on the environment within the meaning of the ''National Environmental Policy Act of 1969'' (NEPA) 42 United States Code (U.S.C.) {section}4321 et seq. For this reason, DOE has prepared this Draft Environmental Impact Statement (EIS) to evaluate potential environmental impacts from the proposed Federal action (granting a Presidential Permit for the proposed transmission facilities) and reasonable alternatives, including the No Action Alternative. This EIS was prepared in accordance with Section 102(2)(c) of NEPA, Council of Environmental Quality (CEQ) regulations (40 Code of Federal Regulations [CFR] 1500-1508), and DOE NEPA Implementing Procedures (10 CFR 1021). DOE is the lead Federal Agency, as defined by 40 CFR 1501.5. The U.S. Department of Agriculture Forest Service (USFS), the Bureau of Land Management (BLM) of the U.S. Department of the Interior, and the U.S. Section of the International Boundary and Water Commission, U.S. and Mexico (USIBWC), are cooperating agencies. Each of these organizations will use the EIS for its own NEPA purposes, as described in the Federal Agencies' Purpose and Need and Authorizing Actions section of this summary. The 345-kV double-circuit transmission line would consist of twelve transmission line wires, or

  12. 49 CFR 192.179 - Transmission line valves.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... line valves must have a blowdown valve with enough capacity to allow the transmission line to be blown down as rapidly as practicable. Each blowdown discharge must be located so the gas can be blown to...

  13. 49 CFR 192.179 - Transmission line valves.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... line valves must have a blowdown valve with enough capacity to allow the transmission line to be blown down as rapidly as practicable. Each blowdown discharge must be located so the gas can be blown to...

  14. View of transmission line tower on LABPL 2 southwest of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View of transmission line tower on LABPL 2 southwest of Boulder City Substation, view southwest - Hoover Dam, Los Angeles Bureau of Power & Light Lines 1-3, U.S. Highway 93, Boulder City, Clark County, NV

  15. Proposed 230-kV Crossover Substation, Big Horn County, Montana: Environmental assessment

    SciTech Connect

    Not Available

    1984-02-01

    Western proposes to construct, operate, and maintain a 230-kV substation northwest of Hardin, Big Horn County, Montana. The proposed Crossover Substation would form an interconnection between Western's Yellowtail-Custer and MPC's Colstrip-Billings 230-kV transmission lines. Impacts and mitigation strategies are discussed.

  16. Number of lightning discharges causing damage to lightning arrester cables for aerial transmission lines in power systems

    SciTech Connect

    Nikiforov, E. P.

    2009-07-15

    Damage by lightning discharges to lightning arrester cables for 110-175 kV aerial transmission lines is analyzed using data from power systems on incidents with aerial transmission lines over a ten year operating period (1997-2006). It is found that failures of lightning arrester cables occur when a tensile force acts on a cable heated to the melting point by a lightning current. The lightning currents required to heat a cable to this extent are greater for larger cable cross sections. The probability that a lightning discharge will develop decreases as the amplitude of the lightning current increases, which greatly reduces the number of lightning discharges which damage TK-70 cables compared to TK-50 cables. In order to increase the reliability of lightning arrester cables for 110 kV aerial transmission lines, TK-70 cables should be used in place of TK-50 cables. The number of lightning discharges per year which damage lightning arrester cables is lowered when the density of aerial transmission lines is reduced within the territory of electrical power systems. An approximate relationship between these two parameters is obtained.

  17. Wind adaptive modeling of transmission lines using minimum description length

    NASA Astrophysics Data System (ADS)

    Jaw, Yoonseok; Sohn, Gunho

    2017-03-01

    The transmission lines are moving objects, which positions are dynamically affected by wind-induced conductor motion while they are acquired by airborne laser scanners. This wind effect results in a noisy distribution of laser points, which often hinders accurate representation of transmission lines and thus, leads to various types of modeling errors. This paper presents a new method for complete 3D transmission line model reconstruction in the framework of inner and across span analysis. The highlighted fact is that the proposed method is capable of indirectly estimating noise scales, which corrupts the quality of laser observations affected by different wind speeds through a linear regression analysis. In the inner span analysis, individual transmission line models of each span are evaluated based on the Minimum Description Length theory and erroneous transmission line segments are subsequently replaced by precise transmission line models with wind-adaptive noise scale estimated. In the subsequent step of across span analysis, detecting the precise start and end positions of the transmission line models, known as the Point of Attachment, is the key issue for correcting partial modeling errors, as well as refining transmission line models. Finally, the geometric and topological completion of transmission line models are achieved over the entire network. A performance evaluation was conducted over 138.5 km long corridor data. In a modest wind condition, the results demonstrates that the proposed method can improve the accuracy of non-wind-adaptive initial models on an average of 48% success rate to produce complete transmission line models in the range between 85% and 99.5% with the positional accuracy of 9.55 cm transmission line models and 28 cm Point of Attachment in the root-mean-square error.

  18. An all solid-state high-voltage ns trigger generator based on magnetic pulse compression and transmission line transformer.

    PubMed

    Lin, Jiajin; Yang, Jianhua; Zhang, Jiande; Chen, Xinbing

    2013-09-01

    Innovative design of an all solid-state high-voltage ns trigger generator, based on magnetic pulse compression and transmission line transformer, is presented. The repetitive trigger pulse generator was developed to trigger a 700 kV trigatron, which has been used to pulse a repetitive intense electron beam accelerator with Tesla transformer charged double pulse forming lines (PFLs). Experimental results show that the trigger pulse generator could produce 180 kV 65 ns duration pulses with a rise time of 20 ns. The repetitive trigger pulses have nice uniform in the voltage waveform. The control time jitter is less then 3 ns. Owing to its good stability and low time jitter, the high-voltage trigger generator is an excellent candidate to trigger the repetitive accelerator.

  19. Resolution enhancement in transmission electron microscopy with 60-kV monochromated electron source

    SciTech Connect

    Morishita, Shigeyuki; Mukai, Masaki; Sawada, Hidetaka; Suenaga, Kazutomo

    2016-01-04

    Transmission electron microscopy (TEM) at low accelerating voltages is useful to obtain images with low irradiation damage. For a low accelerating voltage, linear information transfer, which determines the resolution for observation of single-layered materials, is largely limited by defocus spread, which improves when a narrow energy spread is used in the electron source. In this study, we have evaluated the resolution of images obtained at 60 kV by TEM performed with a monochromated electron source. The defocus spread has been evaluated by comparing diffractogram tableaux from TEM images obtained under nonmonochromated and monochromated illumination. The information limits for different energy spreads were precisely measured by using diffractograms with a large beam tilt. The result shows that the information limit reaches 0.1 nm with an energy width of 0.10 eV. With this monochromated source and a higher-order aberration corrector, we have obtained images of single carbon atoms in a graphene sheet by TEM at 60 kV.

  20. 49 CFR 192.485 - Remedial measures: Transmission lines.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Requirements for Corrosion Control § 192.485 Remedial measures: Transmission lines. (a) General corrosion. Each segment of transmission line with general corrosion and with a remaining wall thickness less than that required for...

  1. 49 CFR 192.485 - Remedial measures: Transmission lines.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Requirements for Corrosion Control § 192.485 Remedial measures: Transmission lines. (a) General corrosion. Each segment of transmission line with general corrosion and with a remaining wall thickness less than that required for...

  2. 49 CFR 192.485 - Remedial measures: Transmission lines.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Requirements for Corrosion Control § 192.485 Remedial measures: Transmission lines. (a) General corrosion. Each segment of transmission line with general corrosion and with a remaining wall thickness less than that required for the...

  3. 49 CFR 192.485 - Remedial measures: Transmission lines.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Requirements for Corrosion Control § 192.485 Remedial measures: Transmission lines. (a) General corrosion. Each segment of transmission line with general corrosion and with a remaining wall thickness less than that required for the...

  4. 49 CFR 192.485 - Remedial measures: Transmission lines.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Requirements for Corrosion Control § 192.485 Remedial measures: Transmission lines. (a) General corrosion. Each segment of transmission line with general corrosion and with a remaining wall thickness less than that required for the...

  5. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Power transmission lines. 644.431 Section 644.431... ESTATE HANDBOOK Disposal Disposal of Fee-Owned Real Property and Easement Interests § 644.431 Power transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus Property Act of...

  6. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 4 2012-07-01 2011-07-01 true Power transmission lines. 644.431 Section 644.431... ESTATE HANDBOOK Disposal Disposal of Fee-Owned Real Property and Easement Interests § 644.431 Power transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus Property Act of...

  7. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 4 2014-07-01 2013-07-01 true Power transmission lines. 644.431 Section 644.431... ESTATE HANDBOOK Disposal Disposal of Fee-Owned Real Property and Easement Interests § 644.431 Power transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus Property Act of...

  8. Identification and characterization of populations living near high-voltage transmission lines: a pilot study.

    PubMed Central

    Wartenberg, D; Greenberg, M; Lathrop, R

    1993-01-01

    Populations living close to high-voltage transmission lines often have residential magnetic field exposures in excess of 1 microT, and sometimes over 2 microT. Yet, populations studied in most epidemiologic investigations of the association between residential magnetic field exposure and cancer typically have exposures below 1 microT and frequently below 0.5 microT. To improve statistical power and precision, it would be useful to compare high exposure populations with low exposure populations rather than only studying small differences within low exposure populations. Toward this end, we have developed an automated method for identifying populations living near high-voltage transmission lines. These populations likely have more highly exposed individuals than the population at large. The method uses a geographic information system (GIS) to superimpose digitized transmission line locations on U.S. Census block location data and then extract relevant demographic data. Analysis of data from a pilot study of the populations residing within 100 m of a 29-km segment of one 230-kV line in New Jersey shows that when compared to populations in the surrounding census blocks farther than 100 m from this line, those populations close to the line have similar demographics but differ in terms of perceived housing value variables. We believe that the approach we have developed will enable investigators to rapidly identify and characterize populations living near high-voltage transmission lines on a statewide basis for considering the impact of exposures and for public policy and that these populations also can be used for epidemiologic study. Images p626-a Figure 1. Figure 2. Figure 3. PMID:8143596

  9. Summit-Watertown transmission line project, South Dakota. Final Environmental Assessment

    SciTech Connect

    Not Available

    1993-12-01

    The Western Area Power Administration (Western) needs to rebuild the existing Summit-Watertown 115-kV transmission line, located in northeastern South Dakota, and western Minnesota. Nearly 60 percent of the existing facility was replaced in 1965 after severe ice-loading broke structures and wires. Because of the extensive loss of the line, surplus poles had to be used to replace the damaged H-frame structures. These were of varying sizes, causing improper structure loading. Additionally, the conductors and overhead shield wires have been spliced in numerous places. This provides additional space on these wires for icing and wind resistance, which in turn create problems for reliability. Finally, a progressive fungal condition has weakened the poles and, along with the improper loading, has created an unsafe condition for maintenance personnel and the general public.

  10. Analog modulation of spike-evoked transmission in CA3 circuits is determined by axonal Kv1.1 channels in a time-dependent manner.

    PubMed

    Bialowas, Andrzej; Rama, Sylvain; Zbili, Mickaël; Marra, Vincenzo; Fronzaroli-Molinieres, Laure; Ankri, Norbert; Carlier, Edmond; Debanne, Dominique

    2015-02-01

    Synaptic transmission usually depends on action potentials (APs) in an all-or-none (digital) fashion. Recent studies indicate, however, that subthreshold presynaptic depolarization may facilitate spike-evoked transmission, thus creating an analog modulation of spike-evoked synaptic transmission, also called analog-digital (AD) synaptic facilitation. Yet, the underlying mechanisms behind this facilitation remain unclear. We show here that AD facilitation at rat CA3-CA3 synapses is time-dependent and requires long presynaptic depolarization (5-10 s) for its induction. This depolarization-induced AD facilitation (d-ADF) is blocked by the specific Kv1.1 channel blocker dendrotoxin-K. Using fast voltage-imaging of the axon, we show that somatic depolarization used for induction of d-ADF broadened the AP in the axon through inactivation of Kv1.1 channels. Somatic depolarization enhanced spike-evoked calcium signals in presynaptic terminals, but not basal calcium. In conclusion, axonal Kv1.1 channels determine glutamate release in CA3 neurons in a time-dependent manner through the control of the presynaptic spike waveform. © 2014 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  11. Nonlinearity of superconducting transmission line and microstrip resonator

    SciTech Connect

    Vendik, O.G.; Vendik, I.B.; Samoilova, T.B.

    1997-02-01

    The simplest model of nonlinear response of a superconducting thin film is used for modeling the nonlinear phenomena in a superconducting transmission line and a microstrip resonator. The specified characteristic power of the transmission line is suggested to use as a fitting parameter for numerical description of the microstrip line nonlinearity at microwaves. Quantitative agreement of simulated and experimental data has been obtained for the incident power dependent transmission coefficient of a microstrip line section and a high quality microstrip resonator. Numerical results have also been obtained for the power of the third harmonic radiated from the nonlinear resonator.

  12. Electrical Characteristics of Sea-Water-Return Transmission Lines

    DTIC Science & Technology

    1982-08-01

    NOROW Reprl 52 Electrical Characteristics of Sea-Water-Return Transmission Lines N. Gholson R. Swenson C. Alexander Ocean Technology Division Ocean...1] Gholson , N. H., Measuring Transmis- 26. Cable #4 has been excluded thus far sion Line Transfer Functions Using a because of its length being 10...Return Final Transmission Lines 6. PERFORMING ORG, REPORT NUMBER 7. AUTHOR(a) S. CONTRACT OR GRANT NUMBER(@) N. Gholson R. Swenson C. Alexander 9

  13. Propagation of microwaves in gradient transmission lines: exactly solvable model

    NASA Astrophysics Data System (ADS)

    Shvartsburg, A. B.; Silin, N. V.

    2015-08-01

    Propagation of microwaves along the transmission line with smoothly continuously distributed capacitance and inductance (gradient transmission line) is considered in the framework of an exactly solvable model. The appearance of strong heterogeneity-induced plasma-like dispersion in gradient transmission line determined by the sizes and shapes of these distributions, is visualized by means of this model. Owing to this dispersion the energy transport in the line discussed can be ensured by both travelling and evanescent microwave modes, characterized by the real and imaginary wave numbers, respectively. The reflectance spectra for microwaves, incident on this heterogeneous transition section located between two homogeneous sections of transmission line are presented, the antireflection properties of this section are demonstrated. The interference of evanescent and anti-evanescent microwave modes is shown to provide the effective weakly attenuated energy transfer in the tunneling regime. The analogy between this microwave system and gradient nano-optical photonic barrier in revealed.

  14. Reclamation and revegetation along a 250-mile 500 kV power line corridor

    SciTech Connect

    Griffith, E.F.

    1990-12-31

    Reclamation and revegetation success along the Montana Power Company Colstrip to Deepdale 500 kV powerline was monitored from 1985 through 1989. Followup revegetation was hampered by inadequate road and tower site earth work as a result of premature release of the reclamation bond. Drought conditions in 1985 and 1988 seriously affected revegetation efforts, especially on difficult sites. Weed control improved markedly, and all ROW areas are weed free except those next to infested range and cropland where a major cooperative effort is needed to control weeds. Access roads in previously unroaded areas resulted in changes of access, management practices, and cattle grazing behavior, all of which adversely affected revegetation success. Erosion, exacerbated by undersized culverts, the presence of very erodible soils, the occasional untrained contractor, is now the major ROW maintenance concern. Observation of the revegetation efforts clearly shows the need for adequate and appropriate reclamation by qualified equipment operators up front, and a patient, measured effort of continued revegetation, weed control and erosion control over the long term. The bond period of 5 years may not be long enough to achieve the 90 percent revegetation success required by the permit. Future projects guidelines should consider look to a flexible timeframe and more realistic vegetation requirements to account for the effects of non-construction related impacts.

  15. a Distance Protection Strategic Spare Relay for 132/66 kv Overhead Lines

    NASA Astrophysics Data System (ADS)

    Harris, R. T.; Roberts, A. G.; Marks, A.; Phipps, W.

    2010-06-01

    The South African electrical supply utility (Eskom) has been experiencing problems in the field of protection, maintenance and in-service breakdowns which influence the quality of electrical supply to the consumer, an important and integral component of the utility business. As a result, further development of the generic relay, implemented as a strategic spare relay for the replacement of several schemes operating within Eskom's southern region has been initiated. These include the electromechanical, solid state and numerical distance protection relays and scheme failures on the 132/66 kV feeder network. The research considers the development, testing and configuration of the strategic spare relay in terms of software and peripheral hardware for the input and output terminal connections, generic equations and settings, for the purpose of scheme replacements. The various schemes are assessed for stepped distance and permissive intertripping for three and single pole operation. This is done in conjunction with the internal and external circuit diagrams to understand the detailed operation of the scheme and to ensure the effective implementation of the strategic spare relay. The generic relay is configured for the emergency replacement of the various schemes during in-service breakdowns. This constitutes a temporary installation and therefore the downtime of all the distance protection schemes that require replacement, is limited to a minimum.

  16. BERTHA: A versatile transmission line and circuit code

    NASA Astrophysics Data System (ADS)

    Hinshelwood, D. D.

    1983-11-01

    An improved version of the NRL transmission line code of W. H. Lupton is presented. The capabilities of the original program were extended to allow magnetically insulated transmission lines, plasma opening switches, imploding plasma loads and discrete element electrical networks, for example, to be modeled. BERTHA is used to simulate any system that is represented by a configuration of transmission line elements. The electrical behavior of the system is calculated by repeatedly summing the reflected and transmitted waves at the ends of each element. This program is versatile, easy to use and easily implemented on desktop microcomputers.

  17. High speed electrical transmission line design and characterization

    NASA Astrophysics Data System (ADS)

    Bates, R.; Buttar, C.; Buytaert, J.; Eklund, L.; de Acedo, L. F. S.; Longstaff, I.; Naik, S.; Sullivan, S.; Wraight, K.

    2017-02-01

    High Energy Physics (HEP) experiments have unique requirements for data communication. High data speeds, combined with extreme restrictions on materials allowed, leads to custom transmission lines. This paper will present transmission line design theory, simulation and testing methods. Transmission line designs options like flexes and rigid PCBs as well as cables will be studied. Finite Element Analysis (FEA) software packages simulate energy dissipation and quality of transmitted signals. The characterisation techniques of time-domain reflectometry and frequency-domain measurements are discussed and compared. Bit-error-rate testing is presented and its limitations for design discussed. Methods to improve quality, like three different types of equalization are described.

  18. Single transmission line interrogated multiple channel data acquisition system

    DOEpatents

    Fasching, George E.; Keech, Jr., Thomas W.

    1980-01-01

    A single transmission line interrogated multiple channel data acquisition system is provided in which a plurality of remote station/sensor circuits each monitors a specific process variable and each transmits measurement values over a single transmission line to a master interrogating station when addressed by said master interrogating station. Typically, as many as 330 remote stations may be parallel connected to the transmission line which may exceed 7,000 feet. The interrogation rate is typically 330 stations/second. The master interrogating station samples each station according to a shared, charging transmit-receive cycle. All remote station address signals, all data signals from the remote stations/sensors and all power for all of the remote station/sensors are transmitted via a single continuous terminated coaxial cable. A means is provided for periodically and remotely calibrating all remote sensors for zero and span. A provision is available to remotely disconnect any selected sensor station from the main transmission line.

  19. 117. Maricopa Dam Water System, Electric Transmission Lines, Catwalk, Derrick ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    117. Maricopa Dam Water System, Electric Transmission Lines, Catwalk, Derrick at Elev. +65. October 15, 1934. - Waddell Dam, On Agua Fria River, 35 miles northwest of Phoenix, Phoenix, Maricopa County, AZ

  20. 29. VIEW OF SIGNAL TRANSMISSION LINES ON NORTH BRIDGE SUPPORT, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. VIEW OF SIGNAL TRANSMISSION LINES ON NORTH BRIDGE SUPPORT, CATENARY ANCHOR BRIDGE 524, NEAR SOUTH NORWALK SWITCH TOWER - New York, New Haven & Hartford Railroad, Automatic Signalization System, Long Island Sound shoreline between Stamford & New Haven, Stamford, Fairfield County, CT

  1. 10. TRANSMISSION LINES BETWEEN DIABLO AND GORGE; CONSTRUCTION DETAIL OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. TRANSMISSION LINES BETWEEN DIABLO AND GORGE; CONSTRUCTION DETAIL OF TOWER STRUCTURE, 1989. - Skagit Power Development, Gorge High Dam, On Skagit River, 2.9 miles upstream from Newhalem, Newhalem, Whatcom County, WA

  2. Electrical and Biological Effects of Transmission Lines: A Review.

    SciTech Connect

    Lee, Jack M.

    1989-06-01

    This review describes the electrical properties of a-c and d-c transmission lines and the resulting effects on plants, animals, and people. Methods used by BPA to mitigate undesirable effects are also discussed. Although much of the information in this review pertains to high-voltage transmission lines, information on distribution lines and electrical appliances is included. The electrical properties discussed are electric and magnetic fields and corona: first for alternating-current (a-c) lines, then for direct current (d-c).

  3. Association between Exposure to Electromagnetic Fields from High Voltage Transmission Lines and Neurobehavioral Function in Children

    PubMed Central

    Huang, Jiongli; Tang, Tiantong; Hu, Guocheng; Zheng, Jing; Wang, Yuyu; Wang, Qiang; Su, Jing; Zou, Yunfeng; Peng, Xiaowu

    2013-01-01

    Background Evidence for a possible causal relationship between exposure to electromagnetic fields (EMF) emitted by high voltage transmission (HVT) lines and neurobehavioral dysfunction in children is insufficient. The present study aims to investigate the association between EMF exposure from HVT lines and neurobehavioral function in children. Methods Two primary schools were chosen based on monitoring data of ambient electromagnetic radiation. A cross-sectional study with 437 children (9 to 13 years old) was conducted. Exposure to EMF from HVT lines was monitored at each school. Information was collected on possible confounders and relevant exposure predictors using standardized questionnaires. Neurobehavioral function in children was evaluated using established computerized neurobehavioral tests. Data was analyzed using multivariable regression models adjusted for relevant confounders. Results After controlling for potential confounding factors, multivariable regression revealed that children attending a school near 500 kV HVT lines had poorer performance on the computerized neurobehavioral tests for Visual Retention and Pursuit Aiming compared to children attending a school that was not in close proximity to HVT lines. Conclusions The results suggest long-term low-level exposure to EMF from HVT lines might have a negative impact on neurobehavioral function in children. However, because of differences in results only for two of four tests achieved statistical significance and potential limitations, more studies are needed to explore the effects of exposure to extremely low frequency EMF on neurobehavioral function and development in children. PMID:23843999

  4. Multimode circuit quantum electrodynamics with hybrid metamaterial transmission lines.

    PubMed

    Egger, D J; Wilhelm, F K

    2013-10-18

    Quantum transmission lines are central to superconducting and hybrid quantum computing. In this work we show how coupling them to a left-handed transmission line allows circuit QED to reach a new regime: multimode ultrastrong coupling. Out of the many potential applications of this novel device, we discuss the preparation of multipartite entangled states and the simulation of the spin-boson model where a quantum phase transition is reached up to finite size effects.

  5. A Proposal for a High Voltage Transmission Line Directional Coupler

    SciTech Connect

    Olsen, Robert; Li, Zhi

    2016-05-01

    Directional couplers are devices generally used in high frequency transmission lines and waveguides that respond to forward and reverse traveling waves separately. Hence they can be used to either measure standing wave ratio in the steady state or to determine the direction of a propagating transient wave. Here, a design is proposed for a directional coupler to be used on multimode high voltage transmission lines. Its performance is analyzed and several suggestions are made for improving its design.

  6. Gas insulated transmission line having tapered particle trapping ring

    DOEpatents

    Cookson, Alan H.

    1982-01-01

    A gas-insulated transmission line includes an outer sheath, an inner conductor, insulating supports and an insulating gas. A particle-trapping ring is secured to each insulating support, and it is comprised of a central portion and two tapered end portions. The ends of the particle trapping ring have a smaller diameter than the central portion of the ring, so as to enable the use of the particle trapping ring in a curved transmission line.

  7. Corrugated outer sheath gas-insulated transmission line

    DOEpatents

    Kemeny, George A.; Cookson, Alan H.

    1981-01-01

    A gas-insulated transmission line includes two transmission line sections each of which are formed of a corrugated outer housing enclosing an inner high-voltage conductor disposed therein, with insulating support means supporting the inner conductor within the outer housing and an insulating gas providing electrical insulation therebetween. The outer housings in each section have smooth end sections at the longitudinal ends thereof which are joined together by joining means which provide for a sealing fixed joint.

  8. ANALYSIS AND SIMULATION OF MAIN MAGNET TRANSMISSION LINE EFFECT

    SciTech Connect

    ZHANG,W.; MARNERIS, I.; SANDBERG, J.

    2007-06-25

    A main magnet chain forms a pair of transmission lines. Pulse-reflection-caused voltage and current differentiation throughout the magnet chain can have adverse effect on main magnet field quality. This effect is associated with magnet system configuration, coupling efficiency, and parasitic parameters. A better understanding of this phenomenon will help us in new design and existing system upgrade. In this paper, we exam the transmission line effect due to different input functions as well as configuration, coupling, and other parameters.

  9. High aspect ratio transmission line circuits micromachined in silicon

    NASA Astrophysics Data System (ADS)

    Todd, Shane Truman

    The performance of complimentary metal-oxide-semiconductor (CMOS) monolithic microwave integrated circuits (MMICs) fabricated on silicon has improved dramatically. The scaling down of silicon transistors has increased the maximum frequency of transistors to the point where silicon MMICs have become a viable alternative to compound semiconductor MMICs in certain applications. A fundamental problem still exists in silicon MMICs however in that transmission lines fabricated on silicon can suffer from high loss due to the finite conductivity of the silicon substrate. A novel approach for creating low-loss transmission lines on silicon is presented in this work. Low-loss transmission lines are created on low resistivity silicon by using a micromachining method that combines silicon deep reactive ion etching (DRIE), thermal oxidation, electroplating, and planarization. Two types of high aspect ratio transmission lines are created with this method including high aspect ratio coplanar waveguide (hicoplanar) and semi-rectangular coaxial (semicoaxial). Transmission lines with impedances ranging from 20--80 O have been fabricated with minimum measured loss lower than 1 dB/cm at 67 GHz. Low-loss dielectrics are created for the high aspect ratio transmission lines using the mesa merging method. The mesa merging method works by creating silicon mesa arrays using DRIE and then converting and merging the mesa arrays into a solid oxide dielectric using thermal oxidation. The transmission lines are designed so that the fields penetrate the low-loss oxide dielectric and are isolated from the lossy silicon substrate. The mesa merging method has successfully created large volume oxide with depth up to 65 microm and width up to 240 microm in short oxidation times. Other advantages of the high aspect ratio transmission lines are demonstrated including low-loss over a wide impedance range, high isolation, and high coupling for coupled-line circuits. Transmission line models have been

  10. Impedance matching with an adjustable segmented transmission line.

    PubMed

    Qian, Chunqi; Brey, William W

    2009-07-01

    A capability for impedance matching between the RF probe and the spectrometer is a standard requirement for NMR. Both lumped element and branched transmission line methods are widely used for this purpose. Here, we propose to use the segmented transmission line structure which is well known in wireless communications. It relies upon reflections between transmission lines of different characteristic impedances that are serially connected to match the impedance of a coil or resonator to the characteristic impedance of the NMR spectrometer. In our implementation, two quarter wave length dielectric slugs are placed within a coaxial transmission line. Adjustment of the positions of the slugs allows the variable tuning and matching needed for NMR probes, eliminating the need for variable capacitors and inductors. As a demonstration of the usefulness of this approach, we have incorporated a variable segmented transmission line into a home-built Variable Angle Spinning probe. Finally, we discuss the range of possible application for segmented transmission line networks in NMR probe design.

  11. Development of High Voltage and High Current Test Bed for Transmission Line Components

    NASA Astrophysics Data System (ADS)

    Jha, Akhil; Patel, Manoj; Harikrishna, JVS; Ajesh, P.; Anand, Rohit; Trivedi, Rajesh; Mukherjee, Aparajita

    2017-04-01

    A test bed for testing of MW level transmission line components, based on the concept of standing wave resonator is being developed at ITER-India, Ion Cyclotron Heating and Current Drive (ICH&CD) lab. This test bed can be configured and operated for various lengths of the resonator for optimum requirement. Estimated 32 kV peak voltage and 650 A peak current can be achieved inside the resonator during operation with an input power level of ∼ 20 kW. In this paper, detailed design and simulation results of test bed using high frequency simulator Microwave Studio (MWS) is presented. A brief description on implementation plan is described as well.

  12. CLASSICAL AREAS OF PHENOMENOLOGY: Magnetically insulated transmission line oscillator oscillated in a modified HEM11 mode

    NASA Astrophysics Data System (ADS)

    Wang, Dong; Chen, Dai-Bing; Qin, Fen; Fan, Zhi-Kai

    2009-10-01

    This paper puts forward a novel magnetically insulated transmission line oscillator (MILO) for the first time which takes a modified HEM11 mode as its main interaction mode. The excitation of the oscillation mode is made possible by carefully adjusting the arrangements of each resonant cavity in a two-dimensional (2-D) slow wave structure. The high frequency characteristics are analyzed and a PIC simulation is carried out; the detailed results are discussed to get a better understanding of this new MILO. Employing an electron beam of about 441 kV and 39.7 kA, it finds that the modified HEM11 mode MILO generates a high power microwave output of about 1.47 GW at 1.45 GHz. The power conversion efficiency is about 8.4% and the generated microwave is in a TE11-like circularly polarized mode; its polarization direction is decided by the rotation direction of the SWS.

  13. High power microwave beam steering based on gyromagnetic nonlinear transmission lines

    NASA Astrophysics Data System (ADS)

    Romanchenko, I. V.; Rostov, V. V.; Gunin, A. V.; Konev, V. Yu.

    2015-06-01

    We demonstrate electronically controlled beam steering by high power RF pulses produced by two gyromagnetic nonlinear transmission lines (NLTLs) connected to a one high voltage driver. Each NLTL is capable of producing several ns RF pulses with peak power from 50 to 700 MW (6% standard deviation) at frequencies from 0.5 to 1.7 GHz (1% standard deviation) with 100 Hz repetition rate. Using a helix antenna allows irradiating of RF pulses with almost circular polarization and 350 MW maximum peak power, which corresponds to 350 kV effective potential of radiation. At the installation of two identical channels, we demonstrate the possibility of beam steering within ±15° in the horizontal plane by coherent RF pulses with circular polarization at 1.0 GHz center frequency. Fourfold increase in the power flux density for in-phase irradiation of RF pulses is confirmed by comparison with one-channel operation.

  14. A Generalized Lossy Transmission-Line Model for Tunable Graphene-Based Transmission Lines with Attenuation Phenomenon

    PubMed Central

    Wu, Yongle; Qu, Meijun; Liu, Yuanan

    2016-01-01

    To investigate the frequency shift phenomenon by inserting graphene, a generalized lossy transmission-line model and the related electrical parameter-extraction theory are proposed in this paper. Three kinds of graphene-based transmission lines with attenuation phenomenon including microstrip line, double-side parallel strip line, and uniplanar coplanar waveguide are analyzed under the common conditions where different chemical potentials are loaded on graphene. The values of attenuation constant and phase constant, and the real and imaginary parts of the characteristic impedance of transmission lines are extracted to analyze in details. When the attenuation constant and the reactance part of the characteristic impedance are approximately equal to zero, this kind of transmission line has low or zero insertion loss. On the contrary, the transmission line is under the radiation mode with obvious insertion loss. The phase constant changes linearly under the transmission mode and can be varied with changing of chemical potentials which attributes to the property of frequency tunability. Furthermore, a bandwidth reconfigurable uniplanar coplanar waveguide power divider is simulated to demonstrate that this theory can be applied to the design of three-port devices. In summary, this work provides a strong potential approach and design theory to help design other kinds of terahertz and mid-infrared reconfigurable devices. PMID:27553759

  15. A Generalized Lossy Transmission-Line Model for Tunable Graphene-Based Transmission Lines with Attenuation Phenomenon

    NASA Astrophysics Data System (ADS)

    Wu, Yongle; Qu, Meijun; Liu, Yuanan

    2016-08-01

    To investigate the frequency shift phenomenon by inserting graphene, a generalized lossy transmission-line model and the related electrical parameter-extraction theory are proposed in this paper. Three kinds of graphene-based transmission lines with attenuation phenomenon including microstrip line, double-side parallel strip line, and uniplanar coplanar waveguide are analyzed under the common conditions where different chemical potentials are loaded on graphene. The values of attenuation constant and phase constant, and the real and imaginary parts of the characteristic impedance of transmission lines are extracted to analyze in details. When the attenuation constant and the reactance part of the characteristic impedance are approximately equal to zero, this kind of transmission line has low or zero insertion loss. On the contrary, the transmission line is under the radiation mode with obvious insertion loss. The phase constant changes linearly under the transmission mode and can be varied with changing of chemical potentials which attributes to the property of frequency tunability. Furthermore, a bandwidth reconfigurable uniplanar coplanar waveguide power divider is simulated to demonstrate that this theory can be applied to the design of three-port devices. In summary, this work provides a strong potential approach and design theory to help design other kinds of terahertz and mid-infrared reconfigurable devices.

  16. A Generalized Lossy Transmission-Line Model for Tunable Graphene-Based Transmission Lines with Attenuation Phenomenon.

    PubMed

    Wu, Yongle; Qu, Meijun; Liu, Yuanan

    2016-08-24

    To investigate the frequency shift phenomenon by inserting graphene, a generalized lossy transmission-line model and the related electrical parameter-extraction theory are proposed in this paper. Three kinds of graphene-based transmission lines with attenuation phenomenon including microstrip line, double-side parallel strip line, and uniplanar coplanar waveguide are analyzed under the common conditions where different chemical potentials are loaded on graphene. The values of attenuation constant and phase constant, and the real and imaginary parts of the characteristic impedance of transmission lines are extracted to analyze in details. When the attenuation constant and the reactance part of the characteristic impedance are approximately equal to zero, this kind of transmission line has low or zero insertion loss. On the contrary, the transmission line is under the radiation mode with obvious insertion loss. The phase constant changes linearly under the transmission mode and can be varied with changing of chemical potentials which attributes to the property of frequency tunability. Furthermore, a bandwidth reconfigurable uniplanar coplanar waveguide power divider is simulated to demonstrate that this theory can be applied to the design of three-port devices. In summary, this work provides a strong potential approach and design theory to help design other kinds of terahertz and mid-infrared reconfigurable devices.

  17. Engineering the electrical characteristics of resonant type metamaterial transmission lines

    NASA Astrophysics Data System (ADS)

    Martin, F.; Bonache, J.; Gil, M.; Sisó, G.

    2008-04-01

    This paper is focused on the control of the electrical characteristics of resonant type metamaterial transmission lines, that is, transmission lines loaded with complementary split ring resonators (CSRRs). The key parameters of metamaterial transmission lines for microwave and millimetre wave circuit design are the characteristic impedance and the phase constant (rather than the effective magnetic permeability or dielectric permittivity). Thanks to the presence of reactive elements loading the host line, metamaterial transmission lines exhibit a major design flexibility that can be useful for circuit design purposes. Specifically, we can tailor the dispersion diagram and the characteristic impedance to some extent. By virtue of this, it is possible the design of microwave and millimetre wave components with superior performance in terms of bandwidth, or the design of multi-band components, both of interest in modern wireless communication systems. Thanks to the small electrical size of the unit cell of such lines, the resulting metamaterial-based components are also very small and fully compatible with planar technology (that is, no lumped elements are used). Different examples are provided to illustrate the possibilities of resonant type metamaterial transmission lines. This includes hybrid couplers, power dividers and phase shifters, among others. The paper includes also the theoretical foundations of the approach.

  18. A Ku-band magnetically insulated transmission line oscillator with overmoded slow-wave-structure

    NASA Astrophysics Data System (ADS)

    Jiang, Tao; He, Jun-Tao; Zhang, Jian-De; Li, Zhi-Qiang; Ling, Jun-Pu

    2016-12-01

    In order to enhance the power capacity, an improved Ku-band magnetically insulated transmission line oscillator (MILO) with overmoded slow-wave-structure (SWS) is proposed and investigated numerically and experimentally. The analysis of the dispersion relationship and the resonant curve of the cold test indicate that the device can operate at the near π mode of the TM01 mode, which is useful for mode selection and control. In the particle simulation, the improved Ku-band MILO generates a microwave with a power of 1.5 GW and a frequency of 12.3 GHz under an input voltage of 480 kV and input current of 42 kA. Finally, experimental investigation of the improved Ku-band MILO is carried out. A high-power microwave (HPM) with an average power of 800 MW, a frequency of 12.35 GHz, and pulse width of 35 ns is generated under a diode voltage of 500 kV and beam current of 43 kA. The consistency between the experimental and simulated far-field radiation pattern confirms that the operating mode of the improved Ku-band MILO is well controlled in π mode of the TM01 mode. Project supported partly by the National Natural Science Foundation of China (Grant No. 61171021).

  19. Relative biological effectiveness of 25 and 10 kV X-rays for the induction of chromosomal aberrations in two human mammary epithelial cell lines.

    PubMed

    Beyreuther, Elke; Dörr, Wolfgang; Lehnert, Anna; Lessmann, Elisabeth; Pawelke, Jörg

    2009-08-01

    Administration of ionizing radiation for diagnostic purposes can be associated with a risk for the induction of tumors. Therefore, particularly with regard to general screening programs, e.g. with mammography, cost-benefit considerations must be discussed including risk estimation depending upon the radiation quality administered. The present study was initiated to investigate the in vitro X-ray energy dependence for the induction of chromosomal aberrations in the two mammary epithelial cell lines, 184A1 and MCF-12A. The induced excess fragments, dicentric chromosomes and centric rings were analyzed and the relative biological effectiveness (RBE) was determined for 10 and 25 kV X-rays relative to 200 kV X-rays. The assumed energy dependence with higher values for 10 kV X-rays was confirmed for the excess fragments, with RBE(M) values of 1.92 +/- 0.26 and 1.40 +/- 0.12 for 10 kV X-rays and 1.17 +/- 0.12 and 0.97 +/- 0.10 for 25 kV photons determined for cell lines 184A1 and MCF-12A, respectively. Meaningful results for the induction of dicentric chromosomes and centric rings were obtained only for higher doses with RBE values of 1.31 +/- 0.21 and 1.70 +/- 0.29 for 184A1 and 1.08 +/- 0.08 and 1.43 +/- 0.12 for MCF-12A irradiated with 25 and 10 kV X-rays, respectively.

  20. New static relay for transmission line protection

    SciTech Connect

    Andrichak, J.G.; Massey, W.A.; Patterson, R.C.

    1981-01-01

    A new static ac voltage relay is described which meets the requirements of critical applications. This Static Line Voltage (SLV) relay consists of three independently adjustable detectors, each of which can be operated in the undervoltage or overvoltage mode. Each detector has a dropout to pickup ratio of 99 percent, and a high degree of immunity to harmonics (less than 3 percent variation in operating point with a voltage waveform containing 50 percent third harmonic). The outputs of the individual detectors are user programmable in the type SLV relay to provide AND, OR, or other logical combinations of output contact wiring to the external control circuits. 2 refs.

  1. Stand-off transmission lines and method for making same

    DOEpatents

    Tuckerman, D.B.

    1991-05-21

    Standoff transmission lines in an integrated circuit structure are formed by etching away or removing the portion of the dielectric layer separating the microstrip metal lines and the ground plane from the regions that are not under the lines. The microstrip lines can be fabricated by a subtractive process of etching a metal layer, an additive process of direct laser writing fine lines followed by plating up the lines or a subtractive/additive process in which a trench is etched over a nucleation layer and the wire is electrolytically deposited. Microstrip lines supported on freestanding posts of dielectric material surrounded by air gaps are produced. The average dielectric constant between the lines and ground plane is reduced, resulting in higher characteristic impedance, less crosstalk between lines, increased signal propagation velocities, and reduced wafer stress. 16 figures.

  2. Stand-off transmission lines and method for making same

    DOEpatents

    Tuckerman, David B.

    1991-01-01

    Standoff transmission lines in an integrated circuit structure are formed by etching away or removing the portion of the dielectric layer separating the microstrip metal lines and the ground plane from the regions that are not under the lines. The microstrip lines can be fabricated by a subtractive process of etching a metal layer, an additive process of direct laser writing fine lines followed by plating up the lines or a subtractive/additive process in which a trench is etched over a nucleation layer and the wire is electrolytically deposited. Microstrip lines supported on freestanding posts of dielectric material surrounded by air gaps are produced. The average dielectric constant between the lines and ground plane is reduced, resulting in higher characteristic impedance, less crosstalk between lines, increased signal propagation velocities, and reduced wafer stress.

  3. Electric transmission line flashover prediction system

    NASA Astrophysics Data System (ADS)

    Amarh, Felix

    Near industrial, agricultural, or coastal areas, contamination is a frequent cause of insulator flashover, most cases of which result in lengthy service interruptions. Utilities spend significant amounts of money on insulator washing and cleaning before the restoration of the service. Laboratory studies and industrial experience have shown that both contamination and wetting of insulator surfaces, which initiate the flow of leakage current, are required for insulator flashover. The leakage current leading to flashover has distinctive stages of development. Flashover is preceded by dry-band arcing and extension of the arc to bridge the insulator. This combination significantly modifies both the magnitude and shape of the leakage current. A condition-based monitoring (CBM) system that monitors the easily measurable insulator leakage current as a means of assessing pollution severity and would possibly predict an approaching flashover could prove beneficial to utilities. The overall aim of this project is the development of a system that monitors pollution build-up through the signature changes in the leakage current and alerts an operator when there is a danger of flashover. The operator can, in turn, order maintenance personnel to wash the insulators. This will safeguard against unforeseen flashovers, since the system is constantly being monitored and diagnosed. Additionally, the washing cycles of insulators will be optimized, saving money and eventually rendering the power transmission system more reliable.

  4. Growth and yield of winter wheat (Triticum aestivum L.) and corn (Zea mays L.) near a high voltage transmission line.

    PubMed

    Soja, G; Kunsch, B; Gerzabek, M; Reichenauer, T; Soja, A-M; Rippar, G; Bolhàr-Nordenkampf, H R

    2003-02-01

    The objective of this study was to determine the effects of an electromagnetic field from a high voltage transmission line on the yield of agricultural crops cultivated underneath and near the transmission line. For 5 years, experiments with winter wheat and corn were carried out near the 380 kV transmission line Dürnrohr (Austria)-Slavetice (Czech Republic). Different field strengths were tested by planting the crops at different distances from the transmission line. The plants were grown in experimental plots (1.77 m2), aligned to equal electric field strengths, and were cultivated according to standard agricultural practice. The soil for all plots was homogenized layer-specifically to a depth of 0.5 m to guarantee uniform soil conditions in the plant root environment. The soil was sampled annually for determinations of carbon content and the behavior of microbial biomass. During development of the vegetation, samples were collected at regular intervals for growth rate analyses. At physiological maturity, the plots (n = 8) were harvested for grain and straw yield determinations. The average electric and magnetic field strengths at four distances from the transmission line (nominal distances: 40, 14, 8, and 2 m) were between 0.2 and 4.0 kV/m and between 0.4 and 4.5 micro T, respectively. No effect of the field exposures on soil microbial biomass could be detected. The wheat grain yields were 7% higher (average of 5 years) in the plots with the lowest field exposure than in the plots nearer to the transmission line (P <.10). The responses of the plants were more pronounced in years with drought episodes during grain filling than in humid years. No significant yield differences were found for corn yields. The extent of the yield variations attributed to the distance from the transmission line was small compared to the observed annual variations in climatic or soil specific site characteristics.

  5. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-222)

    SciTech Connect

    Stratton, Elaine S.

    2004-07-27

    Vegetation Management along the St. John’s - Keeler 115 kV Transmission Line Corridor from 3/1 to 10/6. This corridor includes portions of the Oregon City - Keeler No 2 115 kV transmission line. The corridor along this section of the proposed project is 100 feet in width.

  6. DC Bias Simulation of 1000 kV UHV Transformer Based on MATLAB / Simulink

    NASA Astrophysics Data System (ADS)

    Peng, Hu; Yongjun, Yu; Weili, Wu; Fan, Sun; Xiaoxiao, Qi; Yong, Liu

    2017-07-01

    In order to study the effect of Direct Current bias on the excitation current of 1000kV UHV transformer caused by the parallel operation of DC transmission and AC transmission, this paper builds a simulation model of 1000kV three-winding autotransformer based on MATLAB/Simulink This paper introduces the simulation model of simulation model parameters, and builds a simulation model of 1000kV UHV AC transmission system. Based on the analysis of the change trend of excitation current when the DC voltage source is applied at the neutral point of the transformer, 1000kV transformer, the conclusion is that the DC bias suppression measures and the transmission line design work to provide a theoretical reference.

  7. 75 FR 56051 - Bemidji to Grand Rapids Minnesota 230 kV Transmission Line Project

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-15

    ... Project is being jointly developed by Minnkota, Otter Tail Power Company, and Minnesota Power. DATES..., Coleraine, MN 55722-0225. SUPPLEMENTARY INFORMATION: Minnkota Power, Otter Tail Power, and Minnesota...

  8. 230-kV transmission line upgrade, Jamestown-Grand Forks, North Dakota: Environmental assessment

    SciTech Connect

    Not Available

    1987-01-01

    The proposed project would generally consist of increasing the right-of-way (ROW) width from 75 ft to 125 ft; replacing existing wood three-pole turning structures with taller structures of similar construction; raising the crossarms on the existing tangent structures to accommodate longer insulator strings while maintaining necessary ground clearance; and adding bayonets to the top of the existing tangent structures to raise and support the overhead ground wires. No significant impacts were identified from the resource investigations. Potential moderate impacts were identified for specific sites in the soils, ecological resources, land use, and visual resources components of the environment. The study identified an area of potential moderate land use conflict at the proposed site of the English Coulee retention area. Moderate impact to visual resources was identified at the Sheyenne River crossing due to its distinctive scenic quality. No cultural resources listed in the National Register of Historic Places, or eligible for listing, occur within the project area.

  9. Transmission line matrix modelling of thermal injuries to skin.

    PubMed

    Aliouat Bellia, S; Saidane, A; Hamou, A; Benzohra, M; Saiter, J M

    2008-08-01

    A numerical model based on the transmission line matrix method is presented for the quantitative prediction of skin burn resulting from exposure of a specific region of human skin surface to a high temperature heat source. Transient temperatures were numerically estimated by Pennes' bioheat equation, and the damage function denoting the extent of burn was calculated using the Arrhenius assumptions for protein damage rate. A two-dimensional transmission line matrix model was used to predict the effects of exposure time and structure thicknesses on the transient temperature distribution and damage extent. Compared with other numerical sources the transmission line matrix results revealed good agreement, suggesting that this method may be an effective tool for the thermal diagnostic of burns.

  10. Design of tunable microwave transmission lines using metamaterial cells

    NASA Astrophysics Data System (ADS)

    Bensafieddine, D.; Djerfaf, F.; Chouireb, F.; Vincent, D.

    2017-04-01

    In this paper, frequency tunable transmission lines are designed using metasurface split ring resonator unit cell. We prove that the tuning principle in metasurface transmission lines is based on the variation of the resonance frequency of the permeability. The frequency-tuning arises by changing the values of two gaps in the inner and outer rings of unit cell ( g1 and g2). The branches of a disconnected gaps type conductor of each unit cell can be joined by switches (PIN diodes, MEMs, etc.). According to switch states ON or OFF, the unit cell has four different commutable behaviors which are 00, 01, 11, and 10. The results show that the resonance frequency of our metasurface transmission line is strongly shifted by about 2.5 GHz between the cases (01) and (11).

  11. Residential proximity to high voltage transmission lines and depressive symptomatology

    SciTech Connect

    McMahan, S.G.

    1992-01-01

    A number of epidemiological studies indicate an association between depression and proximity to high voltage transmission lines. These studies have been criticized, however, for using surrogate measures of electromagnetic fields (EMFs) and unstandardized measures of depression. In an effort to overcome these limitations, the Center for Epidemiological Studies Depression (CES-D) scale was administered to 152 women living either adjacent to a transmission line or one block away. Results indicate that homes adjacent to the transmission lines have an average EMF level of 4.86 milligauss at their front door and those one block away have an average of 0.68 milligauss. There was no significant difference in CES-D scores between the groups, controlling for demographic variables. There appeared to be an increase in other health effects, including cancer and miscarriages, but these findings were preliminary and need further investigation.

  12. Quasi-Optical Transmission Line for 94-GHz Radar

    NASA Technical Reports Server (NTRS)

    Perez, Raul M.; Veruttipong, Watt

    2008-01-01

    A quasi-optical transmission line (QOTL) has been developed as a low-loss transmission line for a spaceborne cloudobserving radar instrument that operates at a nominal frequency of 94 GHz. This QOTL could also readily be redesigned for use in terrestrial millimeter-wave radar systems and millimeter-wave imaging systems. In the absence of this or another lowloss transmission line, it would be necessary to use a waveguide transmission line in the original radar application. Unfortunately, transmission losses increase and power-handling capacities of waveguides generally decrease with frequency, such that at 94 GHz, the limitation on transmitting power and the combined transmission and reception losses (greater than 5 dB) in a waveguide transmission line previously considered for the original application would be unacceptable. The QOTL functions as a very-lowloss, three-port circulator. The QOTL includes a shaped input mirror that can be rotated to accept 94-GHz transmitter power from either of two high-power amplifiers. Inside the QOTL, the transmitter power takes the form of a linearly polarized beam radiated from a feed horn. This beam propagates through a system of mirrors, each of which refocuses the beam to minimize diffraction losses. A magnetically biased ferrite disc is placed at one of the foci to utilize the Faraday effect to rotate the polarization of the beam by 45 degrees. The beam is then transmitted via an antenna system. The radar return (scatter from clouds, and/or reflections from other objects) is collected by the same antenna and propagates through the Faraday rotator in the reverse of the direction of propagation of the transmitted beam. In the Faraday rotator, the polarization of the received signal is rotated a further 45 degrees, so that upon emerging from the Faraday rotator, the received beam is polarized at 90 with respect to the transmitted beam. The transmitted and received signals are then separated by a wire-grid polarizer.

  13. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285-SA-32) - Re-Vegetation Plot Study Along the Lower Monumental-McNary Transmission Line ROW

    SciTech Connect

    Hutchinson, Ken

    2001-11-15

    Re-vegetation Plot Study along the Lower Monumental-McNary Transmission Line ROW. The study area sections are located near structures 38/4 and 39/3. The line is a 500kV Single Circuit Transmission Line having an easement width of 165 feet. The proposed work will be accomplished in the indicated sections of the transmission line corridor as indicated on the attached checklist. A summer of 2001 fire burned the subject area leaving the ROW in a bare ground situation. Before, the fire the site was dominated by annual vegetation (cheatgrass) and noxious weeds (yellowstar thistle). As a study of plant succession after the fire for a local Boy Scout group, two 100 X 100 foot areas will be identified for study over the next 2-3 years. The two test plots will be identified and permanently marked. One will receive treatment while the other will not be treated and used as a control plot.

  14. Reconfigurable Wave Velocity Transmission Lines for Phased Arrays

    NASA Technical Reports Server (NTRS)

    Host, Nick; Chen, Chi-Chih; Volakis, John L.; Miranda, Felix

    2013-01-01

    Phased array antennas showcase many advantages over mechanically steered systems. However, they are also more complex, heavy and most importantly costly. This presentation paper presents a concept which overcomes these detrimental attributes by eliminating all of the phase array backend (including phase shifters). Instead, a wave velocity reconfigurable transmission line is used in a series fed array arrangement to allow phase shifting with one small (100mil) mechanical motion. Different configurations of the reconfigurable wave velocity transmission line are discussed and simulated and experimental results are presented.

  15. Gates to Gregg High Voltage Transmission Line Study. [California

    NASA Technical Reports Server (NTRS)

    Bergis, V.; Maw, K.; Newland, W.; Sinnott, D.; Thornbury, G.; Easterwood, P.; Bonderud, J.

    1982-01-01

    The usefulness of LANDSAT data in the planning of transmission line routes was assessed. LANDSAT digital data and image processing techniques, specifically a multi-date supervised classification aproach, were used to develop a land cover map for an agricultural area near Fresno, California. Twenty-six land cover classes were identified, of which twenty classes were agricultural crops. High classification accuracies (greater than 80%) were attained for several classes, including cotton, grain, and vineyards. The primary products generated were 1:24,000, 1:100,000 and 1:250,000 scale maps of the classification and acreage summaries for all land cover classes within four alternate transmission line routes.

  16. Self-monitoring high voltage transmission line suspension insulator

    DOEpatents

    Stemler, Gary E.; Scott, Donald N.

    1981-01-01

    A high voltage transmission line suspension insulator (18 or 22) which monitors its own dielectric integrity. A dielectric rod (10) has one larger diameter end fitting attachable to a transmission line and another larger diameter end fitting attachable to a support tower. The rod is enclosed in a dielectric tube (14) which is hermetically sealed to the rod's end fittings such that a liquidtight space (20) is formed between the rod and the tube. A pressurized dielectric liquid is placed within that space. A discoloring dye placed within this space is used to detect the loss of the pressurized liquid.

  17. Conductor design for the VLHC transmission line magnet

    SciTech Connect

    Foster, G.W.; Kashikhin, V.; McAshan, M.; Mazur, P.O.; Piekarz, H.; Volk, J.T.; Walker, R.

    1999-03-01

    The transmission line magnet [1] is under development for the Very Large Hadron Collider (VLHC) at Fermilab with the expectation that it’s cost will be several times less (per Tesla-meter) than conventional superconducting magnets. It is a dual-aperture warm-iron superferric magnet built around an 80kA superconducting transmission line. The superconductor consists of 8 Rutherford (SSC Outer) cables in an Invar pipe jacket. The conductor design requirements and development program is described. A 100kA conductor test facility based on inductive coupling is described.

  18. TEM transmission line coil with double nuclear capability.

    PubMed

    Erickson, Matthew G; Kurpad, Krishna N; Holmes, James H; Fain, Sean B

    2007-10-01

    MR imaging and spectroscopy requires RF fields of high homogeneity. Quadrature volume coils meeting this requirement include the birdcage coil and the TEM resonator. We describe here a quadrature volume coil designed around a modified coaxial transmission line in which multiple inner conductors are arrayed on a circular perimeter and surrounded by a common shield. Current antinodes are established at appropriate points on the inner conductors by series transmission line stubs, either open circuit or short circuit, which terminate the line. Quadrature phasing is generated by a novel circuit constructed from a pair of high-performance current baluns and a commercial quadrature hybrid. The coil is a "pure" TEM coil as it is simply a resonant transmission line. There is no mode structure to consider. The construction of a prototype quadrature four-element coil is described and preliminary test results from this coil in a 4.7T horizontal bore magnet are reported. A related double nuclear coil design for (3)He and (1)H in which two linear transmission line coils are arrayed on a circular perimeter and simultaneously tuned and matched to their respective frequencies is also described. Preliminary tests from this coil in a 1.5T clinical scanner are reported.

  19. Study of the cavity-magnon-polariton transmission line shape

    NASA Astrophysics Data System (ADS)

    Harder, Michael; Bai, LiHui; Match, Christophe; Sirker, Jesko; Hu, CanMing

    2016-11-01

    We experimentally and theoretically investigate the microwave transmission line shape of the cavity-magnon-polariton (CMP) created by inserting a low damping magnetic insulator into a high quality 3D microwave cavity. While fixed field measurements are found to have the expected Lorentzian characteristic, at fixed frequencies the field swept line shape is in general asymmetric. Such fixed frequency measurements demonstrate that microwave transmission can be used to access magnetic characteristics of the CMP, such as the field line width Δ H. By developing an effective oscillator model of the microwave transmission we show that these line shape features are general characteristics of harmonic coupling. At the same time, at the classical level the underlying physical mechanism of the CMP is electrodynamic phase correlation and a second model based on this principle also accurately reproduces the experimental line shape features. In order to understand the microscopic origin of the effective coupled oscillator model and to allow for future studies of CMP phenomena to extend into the quantum regime, we develop a third, microscopic description, based on a Green's function formalism. Using this method we calculate the transmission spectra and find good agreement with the experimental results.

  20. Measurements and Modeling of Noise on 22.9-kV Medium-Voltage Underground Power Line for Broadband Power Line Communication

    NASA Astrophysics Data System (ADS)

    Lee, Seungjoon; Shin, Donghwan; Kim, Yonghwa; Lee, Jaejo; Eom, Kihwan

    This paper proposed the measurements and modeling of noise on the 22.9-kV Medium-Voltage (MV) underground power distribution cable for Broadband Power Line Communication (BPLC). The proposed measurement system was composed of inductive coupler and Digital Phosphor Oscilloscope (DPO). The measurement noise data was obtained from thirty-two pad mounted transformers in the test field located in Choji area of Ansan city. After conducting analysis of noise characteristics in time and frequency domain, the noise model are presented. In order to analyze the noise in frequency domain, Power Spectral Density (PSD) was computed with empirical data using Welch's method. The modeling of the power line noise at each frequency carried out using Cumulative Probability Distribution (CPD) of the noise power. It compared with common Cumulative Distribution Functions (CDF) of Nakagami-m distribution, Gaussian distribution, Gamma distribution. In low frequency range, gamma distribution was fitted with the CPD. Nakagami-m distribution provides a good fitting to the noise CPD above 20MHz frequency range.

  1. Solid-state repetitive generator with a gyromagnetic nonlinear transmission line operating as a peak power amplifier

    NASA Astrophysics Data System (ADS)

    Gusev, A. I.; Pedos, M. S.; Rukin, S. N.; Timoshenkov, S. P.

    2017-07-01

    In this work, experiments were made in which gyromagnetic nonlinear transmission line (NLTL) operates as a peak power amplifier of the input pulse. At such an operating regime, the duration of the input pulse is close to the period of generated oscillations, and the main part of the input pulse energy is transmitted only to the first peak of the oscillations. Power amplification is achieved due to the voltage amplitude of the first peak across the NLTL output exceeding the voltage amplitude of the input pulse. In the experiments, the input pulse with an amplitude of 500 kV and a half-height pulse duration of 7 ns is applied to the NLTL with a natural oscillation frequency of ˜300 MHz. At the output of the NLTL in 40 Ω coaxial transmission line, the pulse amplitude is increased to 740 kV and the pulse duration is reduced to ˜2 ns, which correspond to power amplification of the input pulse from ˜6 to ˜13 GW. As a source of input pulses, a solid-state semiconductor opening switch generator was used, which allowed carrying out experiments at pulse repetition frequency up to 1 kHz in the burst mode of operation.

  2. HIGH FREQUENCY POWER TRANSMISSION LINE FOR CYCLOTRONS AND THE LIKE

    DOEpatents

    Armstrong, W.J.

    1954-04-20

    High-frequency power transmission systems, particularly a stacked capacitance alternating power current transmission line wherein maximum utilization of the effective conductios skin of the line conductors is achieved while enabling a low impedance to be obtained are reported. The transmission line consists of a number of flat metal strips with interleaved dielectric strips. The metal dielectric strips are coiled spirally with the axis of the spiral extending along the length of the strips, and the alternating metal strips at the output end have outwardly extending aligned lugs which are directly strapped together and connected to the respective terminals on the load. At the input end of the transmission line, similarly, the alternate metal strips are directly strapped together and connected to an altereating current source. With the arrangement described each metal strip conducts on both sides, so that the metal strips are designed to have a thickness corresponding to twice the depth of the "skin effect" conducting lamina of each conductor at the source frequency.

  3. Computer-aided Instructional System for Transmission Line Simulation.

    ERIC Educational Resources Information Center

    Reinhard, Erwin A.; Roth, Charles H., Jr.

    A computer-aided instructional system has been developed which utilizes dynamic computer-controlled graphic displays and which requires student interaction with a computer simulation in an instructional mode. A numerical scheme has been developed for digital simulation of a uniform, distortionless transmission line with resistive terminations and…

  4. Transmission Lines: An Overview of Electrical Properties and Environmental Effects.

    SciTech Connect

    United States. Bonneville Power Administration. Biological Studies Task Team.

    1982-03-01

    A brief overview is provided of environmental and biological effects of high-voltage power transmission lines. Paragraph length descriptions of electric fields, induced voltage and currents, biological effects, magnetic fields, corona, radio and television interference, and ozone are given. 13 figs.

  5. 49 CFR 192.719 - Transmission lines: Testing of repairs.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Testing of repairs. 192.719 Section 192.719 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND..., Aug. 19, 1970, as amended by Amdt. 192-54, 51 FR 41635, Nov. 18, 1986]...

  6. Microstrip-Transmission-Line Shock-Front Sensor

    NASA Technical Reports Server (NTRS)

    Leiweke, Robert J.; Smith, William C.

    1993-01-01

    Microstrip-transmission-line sensor measures velocities of low-overpressure shock fronts and offers dynamic range needed for measurements both far from and near explosions. Fabricated easily, relatively inexpensive, and repaired in field. In addition, basic geometry modified easily, as needed.

  7. High voltage gas insulated transmission line with continuous particle trapping

    DOEpatents

    Cookson, Alan H.; Dale, Steinar J.

    1983-01-01

    This invention provides a novel high voltage gas insulated transmission line utilizing insulating supports spaced at intervals with snap-in means for supporting a continuous trapping apparatus and said trapping apparatus having perforations and cutouts to facilitate trapping of contaminating particles and system flexibility.

  8. 34. DETAIL OF SIGNAL TRANSMISSION LINES AND CIRCUIT BREAKERS ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    34. DETAIL OF SIGNAL TRANSMISSION LINES AND CIRCUIT BREAKERS ON TOP OF BRIDGE, CATENARY ANCHOR BRIDGE 524, NEAR SOUTHWALK SWITCH TOWER - New York, New Haven & Hartford Railroad, Automatic Signalization System, Long Island Sound shoreline between Stamford & New Haven, Stamford, Fairfield County, CT

  9. Airplane Ice Detector Based on a Microwave Transmission Line

    NASA Technical Reports Server (NTRS)

    Ngo, Phong; Arndt, G. Dickey; Carl, James R.

    2004-01-01

    An electronic instrument that could detect the potentially dangerous buildup of ice on an airplane wing is undergoing development. The instrument is based on a microwave transmission line configured as a capacitance probe: at selected spots, the transmission-line conductors are partly exposed to allow any ice and/or liquid water present at those spots to act as predominantly capacitive electrical loads on the transmission line. These loads change the input impedance of the transmission line, as measured at a suitable excitation frequency. Thus, it should be possible to infer the presence of ice and/or liquid water from measurements of the input impedance and/or electrical parameters related to the input impedance. The sensory transmission line is of the microstrip type and thus thin enough to be placed on an airplane wing without unduly disturbing airflow in flight. The sensory spots are small areas from which the upper layer of the microstrip has been removed to allow any liquid water or ice on the surface to reach the transmission line. The sensory spots are spaced at nominal open-circuit points, which are at intervals of a half wavelength (in the transmission line, not in air) at the excitation frequency. The excitation frequency used in the experiments has been 1 GHz, for which a half wavelength in the transmission line is .4 in. (.10 cm). The figure depicts a laboratory prototype of the instrument. The impedance-related quantities chosen for use in this version of the instrument are the magnitude and phase of the scattering parameter S11 as manifested in the in-phase (I ) and quadrature (Q) outputs of the phase detector. By careful layout of the transmission line (including the half-wavelength sensor spacing), one can ensure that the amplitude and phase of the input to the phase detector keep shifting in the same direction as ice forms on one or more of the sensor areas. Although only one transmission-line sensor strip is used in the laboratory version, in a

  10. Applications of Multiconductor Transmission Line Theory to the Prediction of Cable Coupling. Volume I. Multiconductor Transmission Line Theory.

    DTIC Science & Technology

    1976-04-01

    many diverse areas of application. Multiconductor transmission lines have been investigated in early power system studies and continue to receive...attention in this area with regard to the transient behavior of power lines under fault and lightning induced conditions [1-13]. Modern emphasis on...has the interest in predicting transients induced on cables by external electromagnetic field sources such as high power radars or an electromag

  11. Cooperative effects for Qubits in a Transmission Line: Theory

    NASA Astrophysics Data System (ADS)

    Lalumière, K.; Blais, A.; Sanders, B. C.; van Loo, A. F.; Fedorov, A.; Wallraff, A.

    2012-02-01

    Strong extinction of the transmitted power in a 1D transmission line coupled to an artificial atom has recently been achieved [1]. In contrast to the 3D case, large extinctions are made possible by the strong light-matter coupling occurring because of reduced dimensionality. Motivated by this, here we consider the situation where multiple artificial atoms (ie transmon qubits) are coupled to the 1D line. Following the work of Lehmberg for the 3D case [2], we obtain a master equation describing the dynamics of an arbitrary number of qubits coupled to the line. This master equation reveals interaction between the qubits mediated by the line. Using the input-output formalism, the model is compared to experimental results for multiple qubits coupled to the 1D line. [1] O. Astafiev et al., Science 327, 840 (2010) [2] R. H. Lehmberg. Phys. Rev. A 2, 883 (1970).

  12. Power System Reliability Assessment by Analysing Voltage Dips on the Blue Horizon Bay 22KV Overhead Line in the Nelson Mandela Bay Municipality

    NASA Astrophysics Data System (ADS)

    Lamour, B. G.; Harris, R. T.; Roberts, A. G.

    2010-06-01

    Power system reliability problems are very difficult to solve because the power systems are complex and geographically widely distributed and influenced by numerous unexpected events. It is therefore imperative to employ the most efficient optimization methods in solving the problems relating to reliability of the power system. This paper presents a reliability analysis and study of the power interruptions resulting from severe power outages in the Nelson Mandela Bay Municipality (NMBM), South Africa and includes an overview of the important factors influencing reliability, and methods to improve the reliability. The Blue Horizon Bay 22 kV overhead line, supplying a 6.6 kV residential sector has been selected. It has been established that 70% of the outages, recorded at the source, originate on this feeder.

  13. The monitoring results of electromagnetic radiation of 110-kV high-voltage lines in one urban location in Chongqing P.R. China.

    PubMed

    Qin, Qi-Zhong; Chen, Yu; Fu, Ting-Ting; Ding, Li; Han, Ling-Li; Li, Jian-Chao

    2012-03-01

    To understand electromagnetic radiation field strength and its influencing factors of certain 110-kV high-voltage lines in one urban area of Chongqing by measuring 110-kV high-voltage line's electromagnetic radiation level. According to the methodology as determined by the National Hygienic Standards, we selected certain adjacent residential buildings, high-voltage lines along a specific street and selected different distances around its vertical projection point as monitoring points. The levels of electromagnetic radiations were measured respectively. In this investigation within the frequency of 5-1,000 Hz both the electric field strength and magnetic field strength of each monitoring sites were lower than the public exposure standards as determined by the International Commission on Non-Ionizing Radiation Protection. However, the electrical field strength on the roof adjacent to the high-voltage lines was significantly higher than that as measured on the other floors in the same buildings (p < 0.05). The electromagnetic radiation measurements of different monitoring points, under the same high-voltage lines, showed the location which is nearer the high-voltage line maintain a consistently higher level of radiation than the more distant locations (p < 0.05). Electromagnetic radiation generated by high-voltage lines decreases proportionally to the distance from the lines. The buildings can to some extent shield (or absorb) the electric fields generated by high-voltage lines nearby. The electromagnetic radiation intensity near high-voltage lines may be mitigated or intensified by the manner in which the high-voltage lines are set up, and it merits attention for the potential impact on human health.

  14. Wireless Sensor Network for Electric Transmission Line Monitoring

    SciTech Connect

    Alphenaar, Bruce

    2009-06-30

    Generally, federal agencies tasked to oversee power grid reliability are dependent on data from grid infrastructure owners and operators in order to obtain a basic level of situational awareness. Since there are many owners and operators involved in the day-to-day functioning of the power grid, the task of accessing, aggregating and analyzing grid information from these sources is not a trivial one. Seemingly basic tasks such as synchronizing data timestamps between many different data providers and sources can be difficult as evidenced during the post-event analysis of the August 2003 blackout. In this project we investigate the efficacy and cost effectiveness of deploying a network of wireless power line monitoring devices as a method of independently monitoring key parts of the power grid as a complement to the data which is currently available to federal agencies from grid system operators. Such a network is modeled on proprietary power line monitoring technologies and networks invented, developed and deployed by Genscape, a Louisville, Kentucky based real-time energy information provider. Genscape measures transmission line power flow using measurements of electromagnetic fields under overhead high voltage transmission power lines in the United States and Europe. Opportunities for optimization of the commercial power line monitoring technology were investigated in this project to enable lower power consumption, lower cost and improvements to measurement methodologies. These optimizations were performed in order to better enable the use of wireless transmission line monitors in large network deployments (perhaps covering several thousand power lines) for federal situational awareness needs. Power consumption and cost reduction were addressed by developing a power line monitor using a low power, low cost wireless telemetry platform known as the ''Mote''. Motes were first developed as smart sensor nodes in wireless mesh networking applications. On such a platform

  15. A long-pulse repetitive operation magnetically insulated transmission line oscillator.

    PubMed

    Fan, Yu-Wei; Zhong, Hui-Huang; Zhang, Jian-De; Shu, Ting; Liu, Jin Liang

    2014-05-01

    The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube. It has allowed us to generate 3.1 GW pulse of 40 ns duration in the single-pulse operation and 500 MW pulse of 25 ns duration in the repetition rate operation. However, because of the severe impedance mismatch, the power conversion efficiency is only about 4% in the repetition rate operation. In order to eliminate the impedance mismatch and obtain repetitive long-pulse high-power microwave (HPM), a series of experiments are carried out and the recent progress is presented in this paper. In the single-pulse operation, when the diode voltage is 466 kV and current is 41.6 kA, the radiated microwave power is above 2.2 GW, the pulse duration is above 102 ns, the microwave frequency is about 1.74 GHz, and the power conversion efficiency is about 11.5%. In the repetition rate operation, under the condition of the diode voltage about 400 kV, beam current about 38 kA, the radiated microwave power is about 1.0 GW, the pulse duration is about 85 ns. Moreover, the radiated microwave power and the pulse duration decline little by little when the shot numbers increase gradually. The experimental results show that the impedance matching is a vital factor for HPM systems and one of the major technical challenges is to improve the cathode for the repetition rate operation MILO.

  16. A long-pulse repetitive operation magnetically insulated transmission line oscillator

    SciTech Connect

    Fan, Yu-Wei; Zhong, Hui-Huang; Zhang, Jian-De; Shu, Ting; Liu, Jin Liang

    2014-05-15

    The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube. It has allowed us to generate 3.1 GW pulse of 40 ns duration in the single-pulse operation and 500 MW pulse of 25 ns duration in the repetition rate operation. However, because of the severe impedance mismatch, the power conversion efficiency is only about 4% in the repetition rate operation. In order to eliminate the impedance mismatch and obtain repetitive long-pulse high-power microwave (HPM), a series of experiments are carried out and the recent progress is presented in this paper. In the single-pulse operation, when the diode voltage is 466 kV and current is 41.6 kA, the radiated microwave power is above 2.2 GW, the pulse duration is above 102 ns, the microwave frequency is about 1.74 GHz, and the power conversion efficiency is about 11.5%. In the repetition rate operation, under the condition of the diode voltage about 400 kV, beam current about 38 kA, the radiated microwave power is about 1.0 GW, the pulse duration is about 85 ns. Moreover, the radiated microwave power and the pulse duration decline little by little when the shot numbers increase gradually. The experimental results show that the impedance matching is a vital factor for HPM systems and one of the major technical challenges is to improve the cathode for the repetition rate operation MILO.

  17. A long-pulse repetitive operation magnetically insulated transmission line oscillator

    NASA Astrophysics Data System (ADS)

    Fan, Yu-Wei; Zhong, Hui-Huang; Zhang, Jian-De; Shu, Ting; Liu, Jin Liang

    2014-05-01

    The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube. It has allowed us to generate 3.1 GW pulse of 40 ns duration in the single-pulse operation and 500 MW pulse of 25 ns duration in the repetition rate operation. However, because of the severe impedance mismatch, the power conversion efficiency is only about 4% in the repetition rate operation. In order to eliminate the impedance mismatch and obtain repetitive long-pulse high-power microwave (HPM), a series of experiments are carried out and the recent progress is presented in this paper. In the single-pulse operation, when the diode voltage is 466 kV and current is 41.6 kA, the radiated microwave power is above 2.2 GW, the pulse duration is above 102 ns, the microwave frequency is about 1.74 GHz, and the power conversion efficiency is about 11.5%. In the repetition rate operation, under the condition of the diode voltage about 400 kV, beam current about 38 kA, the radiated microwave power is about 1.0 GW, the pulse duration is about 85 ns. Moreover, the radiated microwave power and the pulse duration decline little by little when the shot numbers increase gradually. The experimental results show that the impedance matching is a vital factor for HPM systems and one of the major technical challenges is to improve the cathode for the repetition rate operation MILO.

  18. Near-field thermoacoustic imaging with transmission line pulsers.

    PubMed

    Omar, Murad; Kellnberger, Stephan; Sergiadis, George; Razansky, Daniel; Ntziachristos, Vasilis

    2012-07-01

    Near-field radiofrequency thermoacoustic (NRT) tomography has been recently introduced for imaging electromagnetic (EM) properties of tissues using ultrawideband, high-energy impulses, which induce thermoacoustic responses. Operation in the near-field allows for more effective energy coupling into tissue, compared to using radiating sources, which in turn enables the use of shorter excitation pulses and leads to higher image resolution. This work aimed at investigating transmission lines as a method to generate excitation pulses to improve the NRT resolution over previous implementations without compromising the energy coupled into tissue. The authors implemented a number of custom-made transmission lines to overcome the challenges of the broadband nature of the impulse excitation required in NRT. The authors further constructed phantoms and investigated the performance of the lines in regard to the pulse duration, energy coupling and the resulting resolution, and image quality achieved. Finally, the authors employed mice in order to investigate the performance of the approach in tissue imaging. The authors found that the use of transmission lines resulted in the generation of RF impulses in the range of tens of nanoseconds and shorter. This performance resulted to resolution improvements over previous thermoacoustic imaging implementations, reaching 45 μm resolution, while retaining several tens to hundreds of milli-Joules of energy per pulse. This performance further allowed the visualization and clear differentiation of different mouse structures such as the heart, lung, or spinal cord. The use of transmission lines significantly improved the NRT performance leading to high thermoacoustic tomography imaging quality by coupling adequate amounts of energy within short times at a relatively low cost.

  19. Near-field thermoacoustic imaging with transmission line pulsers.

    PubMed

    Omar, Murad; Kellnberger, Stephan; Sergiadis, George; Razansky, Daniel; Ntziachristos, Vasilis

    2012-07-01

    Near-field radiofrequency thermoacoustic (NRT) tomography has been recently introduced for imaging electromagnetic (EM) properties of tissues using ultrawideband, high-energy impulses, which induce thermoacoustic responses. Operation in the near-field allows for more effective energy coupling into tissue, compared to using radiating sources, which in turn enables the use of shorter excitation pulses and leads to higher image resolution. This work aimed at investigating transmission lines as a method to generate excitation pulses to improve the NRT resolution over previous implementations without compromising the energy coupled into tissue. The authors implemented a number of custom-made transmission lines to overcome the challenges of the broadband nature of the impulse excitation required in NRT. The authors further constructed phantoms and investigated the performance of the lines in regard to the pulse duration, energy coupling and the resulting resolution, and image quality achieved. Finally, the authors employed mice in order to investigate the performance of the approach in tissue imaging. The authors found that the use of transmission lines resulted in the generation of RF impulses in the range of tens of nanoseconds and shorter. This performance resulted to resolution improvements over previous thermoacoustic imaging implementations, reaching 45 μm resolution, while retaining several tens to hundreds of milli-Joules of energy per pulse. This performance further allowed the visualization and clear differentiation of different mouse structures such as the heart, lung, or spinal cord. The use of transmission lines significantly improved the NRT performance leading to high thermoacoustic tomography imaging quality by coupling adequate amounts of energy within short times at a relatively low cost. © 2012 American Association of Physicists in Medicine.

  20. Prevention of Transformer Saturation at a Black Start by Resistor Insertion of 500kV CB

    NASA Astrophysics Data System (ADS)

    Nagashima, Hiroshi; Kosugi, Narifumi; Shimojo, Toshikazu; Furukawa, Nobuhiko; Kusunoki, Kiyoshi; Sugeta, Takayuki

    A generating plant can not energize longer transmission lines at once after blackout. The generating plant energize shorter transmission lines firstly, then circuit breaker turns on to connect other transmission lines through the transformer. Transient over voltage oscillation may occur in the transmission lines caused by the resonance of the transmission line. It is reported that the peak voltage exceeds more than 2p.u. when the non-sinusoidal wave voltage caused by saturation in the transformer core excites the resonated transmission line. This paper describes the effect for preventing saturation of transformer by turning on contactors with appropriate resistors before main contactors of the 500kV circuit breaker. The first part presents the mechanism of preventing saturation in the transformer core by pre-resistor insertion of 500kV circuit breaker. The second part presents the expected effect in the actual power system simulated by analytical model using a transients simulation program, EMTP.

  1. Treatment of biodiversity issues in impact assessment of electricity power transmission lines: A Finnish case review

    SciTech Connect

    Soederman, Tarja . E-mail: tarja.soderman@ymparisto.fi

    2006-05-15

    The Environmental Impact Assessment (EIA) process concerning the route of a 400 kV power transmission line between Loviisa and Hikiae in southern Finland was reviewed in order to assess how biodiversity issues are treated and to provide suggestions on how to improve the effectiveness of treatment of biodiversity issues in impact assessment of linear development projects. The review covered the whole assessment process, including interviews of stakeholders, participation in the interest group meetings and review of all documents from the project. The baseline studies and assessment of direct impacts in the case study were detailed but the documentation, both the assessment programme and the assessment report, only gave a partial picture of the assessment process. All existing information, baseline survey and assessment methods should be addressed in the scoping phase in order to promote interaction between all stakeholders. In contrast to the assessment of the direct effects, which first emphasized impacts on the nationally important and protected flying squirrel but later expanded to deal with the assessment of impacts on ecologically important sites, the indirect and cumulative impacts of the power line were poorly addressed. The public was given the opportunity to become involved in the EIA process. However, they were more concerned with impacts on their properties and less so on biodiversity and species protection issues. This suggests that the public needs to become more informed about locally important features of biodiversity.

  2. Intelligent Video Surveillance for Detecting Snow and Ice Coverage on Electrical Insulators of Power Transmission Lines

    NASA Astrophysics Data System (ADS)

    Gu, Irene Y. H.; Sistiaga, Unai; Berlijn, Sonja M.; Fahlström, Anders

    One of the problems for electrical power delivery through power lines in northern countries is when snow or ice accumulates on electrical insulators. This could lead to snow or ice-induced outages and voltage collapse, causing huge economic loss. This paper proposes a novel real-time intelligent surveillance and image analysis system for detecting and estimating the snow and ice coverage on electric insulators using images captured from an outdoor 420 kV power transmission line. In addition, the swing angle of insulators is estimated, as large swing angles due to wind cause short circuits. Hybrid techniques by combining histogram, edges, boundaries and cross-correlations are employed for handling a broad range of scenarios caused by changing weather and lighting conditions. Experiments have been conducted on the captured images over several month periods. Results have shown that the proposed system has provided valuable estimation results. For image pixels related to snows on the insulator, the current system has yielded an average detection rate of 93% for good quality images, and 67.6% for images containing large amount of poor quality ones, and the corresponding average false alarm ranges from 9% to 18.1%. Further improvement may be achieved by using video-based analysis and improved camera settings.

  3. 7 CFR 1726.76 - Substation and transmission line materials and equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 11 2010-01-01 2010-01-01 false Substation and transmission line materials and... Substation and Transmission Facilities § 1726.76 Substation and transmission line materials and equipment. (a... $500,000 and for all materials. (b) Standards and specifications. Substation and transmission line...

  4. Perfect Thermal Emission by Nanoscale Transmission Line Resonators.

    PubMed

    Liu, Baoan; Gong, Wei; Yu, Bowen; Li, Pengfei; Shen, Sheng

    2017-02-08

    Thermal radiation with a narrow-band emission spectrum is of great importance in a variety of applications such as infrared sensing, thermophotovoltaics, radiation cooling, and thermal circuits. Although resonant nanophotonic structures such as metamaterials and nanocavities have been demonstrated to achieve the narrow-band thermal emission, maximizing their radiation power toward perfect emission still remains challenging. Here, based on the recently developed quasi-normal mode theory, we prove that thermal emission from a nanoscale transmission line resonator can always be maximized by tuning the waveguiding loss of the resonator or bending the structure. By use of nanoscale transmission line resonators as basic building blocks, we experimentally demonstrate a new type of macroscopic perfect and tunable thermal emitters. Our experimental demonstration in conjunction with the general theoretical framework from the quasi-normal mode theory lays the foundation for designing tunable narrow-band thermal emitters with applications in thermal infrared light sources, thermal management, and infrared sensing and imaging.

  5. Comparison of Transmission Line Methods for Surface Acoustic Wave Modeling

    NASA Technical Reports Server (NTRS)

    Wilson, William; Atkinson, Gary

    2009-01-01

    Surface Acoustic Wave (SAW) technology is low cost, rugged, lightweight, extremely low power and can be used to develop passive wireless sensors. For these reasons, NASA is investigating the use of SAW technology for Integrated Vehicle Health Monitoring (IVHM) of aerospace structures. To facilitate rapid prototyping of passive SAW sensors for aerospace applications, SAW models have been developed. This paper reports on the comparison of three methods of modeling SAWs. The three models are the Impulse Response Method (a first order model), and two second order matrix methods; the conventional matrix approach, and a modified matrix approach that is extended to include internal finger reflections. The second order models are based upon matrices that were originally developed for analyzing microwave circuits using transmission line theory. Results from the models are presented with measured data from devices. Keywords: Surface Acoustic Wave, SAW, transmission line models, Impulse Response Method.

  6. Reconfigurable Wave Velocity Transmission Lines for Phased Arrays

    NASA Technical Reports Server (NTRS)

    Host, Nicholas Keith; Chen, Chi-Chih; Volakis, John L.

    2012-01-01

    This presentation discussed a novel phased array with an emphasis to simplify the array feed. Specifically, we will demonstrate a simple, low cost feeding approach by mechanically controlling the substrate thickness. The array feed lines are constructed from parallel plate transmission lines whose thickness are adjusted to control their effective dielectric constant (Epsilon_eff). As a result the phase delay/excitation at each array element will be adjusted per desired beam direction. The proposed antenna elements will be overlapping dipoles operating over a 2:1 bandwidth in the Ku-Band spectrum. Preliminary simulation and experimental demonstration of such an array will be presented.

  7. Flow impedance in a uniform magnetically insulated transmission line

    NASA Astrophysics Data System (ADS)

    Mendel, C. W.; Seidel, D. B.

    1999-12-01

    In two recent publications [C. W. Mendel, Jr. and S. E. Rosenthal, Phys. of Plasmas 2, 1332 (1995), C. W. Mendel, Jr. and S. E. Rosenthal, Phys. of Plasmas 3, 4207 (1996)] relativistic electron flow in cylindrical magnetically insulated transmission lines was analyzed and modeled under the assumption of negligible electron pressure. The model allows power flow in these lines to be accurately calculated under most conditions. The model was developed for coaxial right circular cylindrical electrodes. It is shown here that the model applies equally well to arbitrary cylindrical systems, i.e., systems consisting of electrodes of arbitrary cross section.

  8. Transmission Line for 258 GHz Gyrotron DNP Spectrometry

    NASA Astrophysics Data System (ADS)

    Bogdashov, Alexandr A.; Belousov, Vladimir I.; Chirkov, Alexey V.; Denisov, Gregory G.; Korchagin, Vyacheslav V.; Kornishin, Sergey Yu.; Tai, Evgeny M.

    2011-06-01

    We describe the design and test results of the transmission line for liquid-state (LS) and solid-state (SS) DNP spectrometers with the second-harmonic 258.6 GHz gyrotron at the Institute of the Biophysical Chemistry Center of Goethe University (Frankfurt). The 13-meter line includes a mode converter, HE11 waveguides, 4 mitre bends, a variable polarizer-attenuator, directional couplers, a water-flow calorimeter and a mechanical switch. A microwave power of about 15 W was obtained in the pure HE11 mode at the spectrometer inputs.

  9. Gas insulated transmission line with insulators having field controlling recesses

    DOEpatents

    Cookson, Alan H.; Pederson, Bjorn O.

    1984-01-01

    A gas insulated transmission line having a novel insulator for supporting an inner conductor concentrically within an outer sheath. The insulator has a recess contiguous with the periphery of one of the outer and inner conductors. The recess is disposed to a depth equal to an optimum gap for the dielectric insulating fluid used for the high voltage insulation or alternately disposed to a large depth so as to reduce the field at the critical conductor/insulator interface.

  10. Power transmission line operating modes calculation with controllable phase shifters

    NASA Astrophysics Data System (ADS)

    Astashev, M. G.; Novikov, M. A.; Panfilov, D. I.; Rashitov, P. A.; Remizevich, T. V.; Fedorova, M. I.

    2016-12-01

    The article contains the analysis of the influence of the phase shifter (PS) on the energy processes in the power transmission line in terms of the two-unit model of the electric network. The approach to synthesis of the models regulated by the phase shifter providing for both calculation of the steady operation modes of the electric networks with the phase shifters and research of the electromagnetic processes and designing of the device itself is offered.

  11. Fiber optic transmission line stabilization apparatus and method

    NASA Technical Reports Server (NTRS)

    Lutes, G. F., Jr.; Lau, K. Y. (Inventor)

    1981-01-01

    A reference signal of RF frequency modulates a 0.85 micrometer wavelength optical transmitter. The output of which passes through a first optical filter and a voltage-controller phase shifter. The output of the phase shifter is provided to the fiber optic transmission line. At the receiving end of the transmission line, the signal is demodulated and used to modulate a 1.06 micrometer optical transmitter. The signal from the transmitter is provided to the fiber optic transmission line and passes through the voltage-controlled phase shifter to a phase error detector. The phase of the modulation of the 1.06 micrometer wavelength signal is compared to the phase of the reference signal by the phase error detector. A phase control signal related to the phase difference is provided to the voltage controlled phase shifter which alters the phase of both optical signals until a predetermined phase relationship between modulation on the 1.06 micrometer signal and the reference signal is obtained.

  12. 138 kV 12-phase as an alternative to 345 kV 3-phase

    SciTech Connect

    Stewart, J.R.; Hudson, T.L.

    1988-04-01

    Recent high phase order reserch has resulted in a 138 kV (phase-to-ground) 12-phase line design which is a realistic alternatice to 345 kV 3-phase transmission. This paper presnts the results of an experimental and analytical program which included construction of a 12-phase steel lattice portal tower special insulators, consttruction of a 12-phase substation, and subsequent energization of the world's first 12-phase power transmission line. Impedences, electrical environmental effects (radio noise, audible noise, and electric fields) are among the parameters measured and evaluated. This 12-phase design is compared with sevral existing 345 kV 3-phase lines for thermal and surge impedance loading, electrical environmental effects and physical size requirements. The 12-phase design offers comparable loading in less space with reduced electrical environmental impact. This is illustrative of the possibilities of high phase order as a replacement for 3-phase at other voltage levels. 9 refs., 13 figs., 2 tabs.

  13. High-voltage isolation transformer for sub-nanosecond rise time pulses constructed with annular parallel-strip transmission lines.

    PubMed

    Homma, Akira

    2011-07-01

    A novel annular parallel-strip transmission line was devised to construct high-voltage high-speed pulse isolation transformers. The transmission lines can easily realize stable high-voltage operation and good impedance matching between primary and secondary circuits. The time constant for the step response of the transformer was calculated by introducing a simple low-frequency equivalent circuit model. Results show that the relation between the time constant and low-cut-off frequency of the transformer conforms to the theory of the general first-order linear time-invariant system. Results also show that the test transformer composed of the new transmission lines can transmit about 600 ps rise time pulses across the dc potential difference of more than 150 kV with insertion loss of -2.5 dB. The measured effective time constant of 12 ns agreed exactly with the theoretically predicted value. For practical applications involving the delivery of synchronized trigger signals to a dc high-voltage electron gun station, the transformer described in this paper exhibited advantages over methods using fiber optic cables for the signal transfer system. This transformer has no jitter or breakdown problems that invariably occur in active circuit components.

  14. Development of Live-working Robot for Power Transmission Lines

    NASA Astrophysics Data System (ADS)

    Yan, Yu; Liu, Xiaqing; Ren, Chengxian; Li, Jinliang; Li, Hui

    2017-07-01

    Dream-I, the first reconfigurable live-working robot for power transmission lines successfully developed in China, has the functions of autonomous walking on lines and accurately positioning. This paper firstly described operation task and object of the robot; then designed a general platform, an insulator replacement end and a drainage plate bolt fastening end of the robot, presented a control system of the robot, and performed simulation analysis on operation plan of the robot; and finally completed electrical field withstand voltage tests in a high voltage hall as well as online test and trial on actual lines. Experimental results show that by replacing ends of manipulators, the robot can fulfill operation tasks of live replacement of suspension insulators and live drainage plate bolt fastening.

  15. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-37)

    SciTech Connect

    Martin, Mark A.

    2002-01-17

    Vegetation Management along the Monroe-Custer No.1 Transmission Line ROW from 29/1+915 to 45/4+975. The transmission line is 500 kV single circuit transmission line. Project includes adjacent Monroe-Custer No.2 and Arlington-Bellingham single circuit transmission lines having a combined ROW width of 421.5 feet. The proposed work will be accomplished in the indicated sections of the transmission line corridor.

  16. Pulse sharpening effects of thin film ferroelectric transmission lines

    NASA Astrophysics Data System (ADS)

    Sleezer, Robert J.

    Advances in material science have resulted in the development of electrically nonlinear high dielectric thin film ferroelectrics, which have led to new opportunities for the creation of novel devices. This dissertation investigated one such device: a low voltage nonlinear transmission line (NLTL). A finite element simulation of ferroelectric transmission lines showed that NLTLs are capable of creating shockwaves. Additionally, if the losses are kept sufficiently low, it was shown that voltage gain should be possible. Furthermore, a method of accounting for material dispersion was developed. Results from simulations including material dispersion showed that temporal solitons might be possible from a continuous ferroelectric based nonlinear transmission line. Fabrication of a thin film ferroelectric NLTL required the growth of a ferroelectric material on a conductive substrate. Barium titanate (BTO), which has been gaining popularity due to its high dielectric constant, strong nonlinearity, and lack of lead, was grown. Molecular beam epitaxy and sol-gel growth were both explored and sol-gel was chosen as the growth method for the final device, in part due to its ability to grow BTO thin films on highly conductive nickel substrates. Samples approximately 330 nm thick were grown by this method. Oxygen vacancies in the as grown BTO films were filled by annealing in low pressure oxygen environments. X-ray diffraction measurements were used to determine an O2 pressure for oxidation that was slightly less than the pressure at which NiO forms to ensure maximum filling of the vacancies in the BTO. Grown samples were successfully shown to have ferroelectric properties. A lumped element transmission line was fabricated using discrete capacitors and inductors with a sample as described above. Test capacitors were fabricated and used to determine the dielectric constant of the BTO thin film. This was used to select capacitor pad sizes and inductor values to create a 50 Ohm line

  17. Radiofrequency transmission line for bioluminescent Vibrio sp. irradiation

    NASA Astrophysics Data System (ADS)

    Nassisi, V.; Alifano, P.; Talà, A.; Velardi, L.

    2012-07-01

    We present the study and the analyses of a transmission line for radiofrequency (RF) irradiation of bacteria belonging to Vibrio harveyi-related strain PS1, a bioluminescent bacterium living in symbiosis with many marine organisms. The bioluminescence represents a new biologic indicator which is useful for studying the behaviour of living samples in the presence of RF waves due to the modern communication systems. A suitable transmission line, used as an irradiating cell and tested up to the maximum frequency used by the global system for mobile communications and universal mobile telecommunications system transmissions, was characterized. In this experiment, the RF voltage applied to the transmission line was 1 V. Due to short dimensions of the line and the applied high frequencies, standing waves were produced in addition to progressing waves and the electric field strength varies particularly along the longitudinal direction. The magnetic field map was not strongly linked to the electric one due to the presence of standing waves and of the outgoing irradiation. RF fields were measured by two homemade suitable probes able to diagnostic fields of high frequency. The field measurements were performed without any specimens inside the line. Being our sample made of living matter, the real field was modified and its value was estimated by a simulation code. The bioluminescence experiments were performed only at 900 MHz for two different measured electric fields, 53 and 140 V/m. The light emission was measured right from the beginning and after 7 and 25 h. Under RF irradiation, we found that the bioluminescence activity decreased. Compared with the control sample, the diminution was 6.8% and 44% after 7 and 25 h of irradiation, respectively, both with the low or high field. No changes of the survival factor for all the samples were observed. Besides, to understand the emission processes, we operated the deconvolution of the spectra by two Gaussian curves. The Gaussian

  18. Effects of high-voltage transmission lines on honey bees

    SciTech Connect

    Greenberg, B.; Bindokas, V.P.

    1981-04-01

    Data are reported on the effect of hive height and current distribution on honey bees hived under a 765 kV line (E-field ca. 7 kV/m). Hive height was standardized with adjustable collectors to 1 meter (59 ..mu..A total hive current) or 1.5 meter (85 ..mu..A) equivalents; controls were shielded. A 1.5 meter group with completely painted supers was included. After 8 or 16 weeks of exposure there was no effect on honey moisture content or weight of young workers in any group. Worker capped brood was not affected in 1 m hives but declined significantly in 1.5 m hives after 4 weeks of exposure and this was associated with queen loss, abnormal queen cell production, and colony failure. Weight gain was depressed in all hives after 2 weeks of exposure and was dose related, with the taller hives more severely affected. Only the exposed hives propolized entrances but the amount and time of onset were not dose related. The 1.5 m hives with painted interiors behaved like the 1 m hives with unpainted interiors in all respects, although their total hive current approximated the other group of 1.5 m hives. Reversal of treatments at midseason resulted in reversal of colony behavior, manifested most clearly with respect to hive weight, less with respect to brood. When first exposed, colonies exhibit pronounced but transient elevations in hive temperature. Bio-effects were more severe during the first period when hives had fewer bees. Total hive current was greater in wet than in dry periods. All these factors influence observed bioeffects.

  19. Transmission line transformer for reliable and low-jitter triggering of a railgap switch.

    PubMed

    Verma, Rishi; Mishra, Ekansh; Sagar, Karuna; Meena, Manraj; Shyam, Anurag

    2014-09-01

    The performance of railgap switch critically relies upon multichannel breakdown between the extended electrodes (rails) in order to ensure distributed current transfer along electrode length and to minimize the switch inductance. The initiation of several simultaneous arc channels along the switch length depends on the gap triggering technique and on the rate at which the electric field changes within the gap. This paper presents design, construction, and output characteristics of a coaxial cable based three-stage transmission line transformer (TLT) that is capable of initiating multichannel breakdown in a high voltage, low inductance railgap switch. In each stage three identical lengths of URM67 coaxial cables have been used in parallel and they have been wounded in separate cassettes to enhance the isolation of the output of transformer from the input. The cascaded output impedance of TLT is ~50 Ω. Along with multi-channel formation over the complete length of electrode rails, significant reduction in jitter (≤2 ns) and conduction delay (≤60 ns) has been observed by the realization of large amplitude (~80 kV), high dV/dt (~6 kV/ns) pulse produced by the indigenously developed TLT based trigger generator. The superior performance of TLT over conventional pulse transformer for railgap triggering application has been compared and demonstrated experimentally.

  20. Transmission line transformer for reliable and low-jitter triggering of a railgap switch

    NASA Astrophysics Data System (ADS)

    Verma, Rishi; Mishra, Ekansh; Sagar, Karuna; Meena, Manraj; Shyam, Anurag

    2014-09-01

    The performance of railgap switch critically relies upon multichannel breakdown between the extended electrodes (rails) in order to ensure distributed current transfer along electrode length and to minimize the switch inductance. The initiation of several simultaneous arc channels along the switch length depends on the gap triggering technique and on the rate at which the electric field changes within the gap. This paper presents design, construction, and output characteristics of a coaxial cable based three-stage transmission line transformer (TLT) that is capable of initiating multichannel breakdown in a high voltage, low inductance railgap switch. In each stage three identical lengths of URM67 coaxial cables have been used in parallel and they have been wounded in separate cassettes to enhance the isolation of the output of transformer from the input. The cascaded output impedance of TLT is ˜50 Ω. Along with multi-channel formation over the complete length of electrode rails, significant reduction in jitter (≤2 ns) and conduction delay (≤60 ns) has been observed by the realization of large amplitude (˜80 kV), high dV/dt (˜6 kV/ns) pulse produced by the indigenously developed TLT based trigger generator. The superior performance of TLT over conventional pulse transformer for railgap triggering application has been compared and demonstrated experimentally.

  1. Repetitive operation of an L-band magnetically insulated transmission line oscillator with metal array cathode.

    PubMed

    Qin, Fen; Wang, Dong; Xu, Sha; Zhang, Yong; Fan, Zhi-Kai

    2016-04-01

    We present the repetitive operation research results of an L-band magnetically insulated transmission line oscillator with metal array cathode (MAC-MILO) in this paper. To ensure a more uniform emission of electrons emitted from the cathode, metal plates with different outer radii and thicknesses are periodically arranged in longitudinal direction on the cathode substrate to act as emitters. The higher order mode depressed MILO (HDMILO) structure is applied to ensure stability of the tube. Comparison experiments are carried out between velvet cathode and MAC MILO driven by a 20 GW/40 Ω/40 ns/20 Hz pulse power system. Experimental results reveal that the MAC has much lower outgassing rate, much longer life time, and higher repetitive stability. The MAC-MILO could work stably with a rep-rate up to 20 Hz at a power level of 550 MW when employing a 350 kV/35 kA electric pulse. The TE11 mode radiation pattern in the farfield region reveals the tube works steadily on the dominant mode. More than 2000 shots have been tested in repetitive mode without any obvious degradation of the detected microwave parameters.

  2. Repetitive operation of an L-band magnetically insulated transmission line oscillator with metal array cathode

    NASA Astrophysics Data System (ADS)

    Qin, Fen; Wang, Dong; Xu, Sha; Zhang, Yong; Fan, Zhi-kai

    2016-04-01

    We present the repetitive operation research results of an L-band magnetically insulated transmission line oscillator with metal array cathode (MAC-MILO) in this paper. To ensure a more uniform emission of electrons emitted from the cathode, metal plates with different outer radii and thicknesses are periodically arranged in longitudinal direction on the cathode substrate to act as emitters. The higher order mode depressed MILO (HDMILO) structure is applied to ensure stability of the tube. Comparison experiments are carried out between velvet cathode and MAC MILO driven by a 20 GW/40 Ω/40 ns/20 Hz pulse power system. Experimental results reveal that the MAC has much lower outgassing rate, much longer life time, and higher repetitive stability. The MAC-MILO could work stably with a rep-rate up to 20 Hz at a power level of 550 MW when employing a 350 kV/35 kA electric pulse. The TE11 mode radiation pattern in the farfield region reveals the tube works steadily on the dominant mode. More than 2000 shots have been tested in repetitive mode without any obvious degradation of the detected microwave parameters.

  3. Component tests for the ITER Ion Cyclotron Transmission Line and Matching System - Status and Plans

    NASA Astrophysics Data System (ADS)

    Goulding, R. H.; McCarthy, M. P.; Deibele, C. E.; Rasmussen, D. A.; Swain, D. W.; Barber, G. C.; Campbell, I. H.; Gray, S. L.; Moon, R. L.; Pesavento, P. V.; Sanabria, R. M.; Fredd, E.; Greenough, N.; Kung, C.

    2015-11-01

    New Z0 = 50 Ω gas-cooled component designs for the ITER Ion Cyclotron Heating and Current Drive System have been successfully tested at high RF power levels. They include two types featuring spoke-ring assembly (SRA) inner conductor supports: 20° elbows, and variable length assembly bellows, both achieving RF voltages > 35 kV peak, and currents ~ 760 A peak during quasi-steady state operation. The SRA utilizes mechanically preloaded fused quartz spokes, increasing lateral load handling capability. Components with SRA supports have been seismically tested, with no variation in low power electrical performance detected after testing. A 3 MW four-port switch has also been successfully tested at high RF power, and tests of a 6 MW hybrid power splitter are planned in the near future. Latest results will be presented. Plans for arc localization tests in a 60 m SRA transmission line run, and RF tests of Z0 = 50 Ω and Z0 = 20 Ω matching components with water-cooled inner conductors will also be discussed. This manuscript has been authored by UT-Battelle, LLC, under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy.

  4. Repetitive operation of an L-band magnetically insulated transmission line oscillator with metal array cathode

    SciTech Connect

    Qin, Fen; Wang, Dong Xu, Sha; Zhang, Yong; Fan, Zhi-kai

    2016-04-15

    We present the repetitive operation research results of an L-band magnetically insulated transmission line oscillator with metal array cathode (MAC-MILO) in this paper. To ensure a more uniform emission of electrons emitted from the cathode, metal plates with different outer radii and thicknesses are periodically arranged in longitudinal direction on the cathode substrate to act as emitters. The higher order mode depressed MILO (HDMILO) structure is applied to ensure stability of the tube. Comparison experiments are carried out between velvet cathode and MAC MILO driven by a 20 GW/40 Ω/40 ns/20 Hz pulse power system. Experimental results reveal that the MAC has much lower outgassing rate, much longer life time, and higher repetitive stability. The MAC-MILO could work stably with a rep-rate up to 20 Hz at a power level of 550 MW when employing a 350 kV/35 kA electric pulse. The TE{sub 11} mode radiation pattern in the farfield region reveals the tube works steadily on the dominant mode. More than 2000 shots have been tested in repetitive mode without any obvious degradation of the detected microwave parameters.

  5. Environmental justice: a contrary finding for the case of high-voltage electric power transmission lines.

    PubMed

    Wartenberg, Daniel; Greenberg, Michael R; Harris, Gerald

    2010-05-01

    Environmental justice is the consideration of whether minority and/or lower-income residents in a geographic area are likely to have disproportionately higher exposures to environmental toxins than those living elsewhere. Such situations have been identified for a variety of factors, such as air pollution, hazardous waste, water quality, noise, residential crowding, and housing quality. This study investigates the application of this concept to high-voltage electric power transmission lines (HVTL), which some perceive as a health risk because of the magnetic fields they generate, and also as esthetically unpleasing. We mapped all 345 kV and higher voltage HVTL in New York State and extracted and summarized proximate US Census sociodemographic and housing characteristic data into four categories on the basis of distances from HVTL. Contrary to our expectation, people living within 2000 ft from HVTL were more likely to be exposed to magnetic fields, white, of higher income, more educated and home owners, than those living farther away, particularly in urban areas. Possible explanations for these patterns include the desire for the open space created by the rights-of-way, the preference for new homes/subdivisions that are often located near HVTL, and moving closer to HVTL before EMFs were considered a risk. This study suggests that environmental justice may not apply to all environmental risk factors and that one must be cautious in generalizing. In addition, it shows the utility of geographical information system methodology for summarizing information from extremely large populations, often a challenge in epidemiology.

  6. Development of MisMatch Transmission Line (MMTL) system for ICH&CD test rig

    NASA Astrophysics Data System (ADS)

    Ajesh, P.; Jha, Akhil; Anand, Rohit; Harikrishna, JVS; Trivedi, Rajesh; Mukherjee, Aparajita

    2015-12-01

    India is responsible for delivery of 8+1(prototype) RF sources to ITER Organization. Each RF source will provide 2.5MW of RF power at 2 VSWR in the frequency range of 35 to 65MHz with other stringent specifications. To test the sources at full performance, India is developing unique 3MW test facility with variable load condition (up to VSWR 3.0 at any phase angle in between 0°-360°), consisting of high power 50 Ohm dummy load, phase shifter and stub. The combined assembly of phase shifter and stub is called MisMatch Transmission Line (MMTL) system. Detailed RF and thermal simulation of the MMTL system has been done as a part of developmental activity. Simulations predict maximum RF voltage and current in the MMTL system are 18kV and 400A, respectively. Thermal simulation shows that system can be operated at 1.7MW/CW/3VSWR without active cooling. A detailed design and initial test results of MMTL system considering RF & mechanical aspect for testing ITER ICRF sources is described in this paper.

  7. Transmission Line Properties of Nickel-Bodied Proportional Counters

    NASA Astrophysics Data System (ADS)

    Ryu, Jennifer

    2008-10-01

    Simultaneous measurements of neutral current and charged current neutrino scattering events allowed the Sudbury Neutrino Observatory (SNO) to demonstrate definitively neutrino oscillation. The three phases of the SNO detector are distinguished by different techniques of detecting the neutrons produced by neutral current neutrino scattering. In the final phase, nickel-bodied proportional counters filled with ^3He were used as neutral current detectors (NCDs) by observing the charged particles produced by neutron capture on ^3He. If we can understand the electrical transmission properties of the NCDs, we can use the different pulse shapes produced by neutron captures compared to those of alphas to distinguish these events and gain more sensitivity to the neutral current events. We found that because of the ferromagnetism of the nickel, standard calculations provided for proportional counters are not accurate enough. To obtain a better calculation, we directly measured the electrical properties of the transmission line as a function of frequency. This is a presentation of our results.

  8. View facing northeast (60°) of Structure 259, other transmission lines ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View facing northeast (60°) of Structure 25-9, other transmission lines and small farmstead visible in background - Havre Rainbow Transmission Line, Havre City to Great Falls vicinity, Montana, Great Falls, Cascade County, MT

  9. View facing north (30°) of Transmission Line entering Teton River ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View facing north (30°) of Transmission Line entering Teton River Valley, near Structure 40-7 - Havre Rainbow Transmission Line, Havre City to Great Falls vicinity, Montana, Great Falls, Cascade County, MT

  10. View facing south (210°) of Transmission Line going over hill, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View facing south (210°) of Transmission Line going over hill, Structure 46-12 in foreground, near Collins School - Havre Rainbow Transmission Line, Havre City to Great Falls vicinity, Montana, Great Falls, Cascade County, MT

  11. Transmission Line Analysis of Dielectric-Loaded Ferrite Kicker

    SciTech Connect

    Hahn, H.

    1994-02-03

    The RHIC injection kicker is constructed as a C-shaped ferrite kicker in which the ferrite blocks are spaced apart and the interstice is filled with high-permittivity ceramic. Due to this ferrite-dielectric composite structure, the kicker behaves like a transmission line rather than a lumped inductor. The electric properties of the kicker, nota bene characteristic impedance and propagation velocity, have been analyzed by Forsyth and his colleagues, Claus and Zhang, as a low pass filter with lumped L and C elements.

  12. Modeling of planar quasi-TEM superconducting transmission lines

    NASA Technical Reports Server (NTRS)

    Antsos, Dimitrios; Chew, Wilbert; Riley, A. L.; Hunt, Brian D.; Foote, Marc C.; Bajuk, Louis J.; Rascoe, Daniel L.; Cooley, Thomas W.

    1992-01-01

    An application of the phenomenological loss equivalence method (Lee and Itoh, 1989) in modeling the microwave behavior of planar quasi-TEM superconducting transmission lines is presented. For validation of the model, data are used from measurements of a YBCO superconducting thin-film coplanar-waveguide lowpass filter on a lanthanum aluminate substrate. Measured and modeled S-parameters of an existing superconducting coplanar waveguide lowpass filter agree to within 0.3 dB in magnitude and 0.5 radians in phase. Extracted values for penetration depth and real part of the conductivity of the superconducting film are within 10 percent of other researchers' findings.

  13. Field quality measurements of a 2-Tesla transmission line magnet

    SciTech Connect

    Velev, G.V.; Foster, W.; Kashikhin, V.; Mazur, P.; Oleck, A.; Piekarz, H.; Schlabach, P.; Sylvester, C.; Wake, M.; /KEK, Tsukuba

    2005-09-01

    A prototype 2-Tesla superconducting transmission line magnet for future hadron colliders was designed, built and tested at Fermilab. The 1.5 m long, combined-function gradient-dipole magnet has a vertical pole aperture of 20 mm. To measure the magnetic field quality in such a small magnet aperture, a specialized rotating coil of 15.2 mm diameter, 0.69 m long was fabricated. Using this probe, a program of magnetic field quality measurements was successfully performed. Results of the measurements are presented and discussed.

  14. Walking Posture Control of Transmission Line Single Arm Inspection Robot

    NASA Astrophysics Data System (ADS)

    Yan, Yu; Liu, Xiaqing; Li, Jinliang; Ou, Yuexiong

    2017-07-01

    To control the walking posture according to transmission line single arm inspection robot, the robot is divided into normal walking and climbing walking two state, and gives the definition, then based on the state space method of state variable feedback and PD control method is used to control the two states, two kinds of control method of simulation by using Matlab, in the end, the two control methods proposed is validated in the actual circuit structures. The results show that, the proposed control method is rapid and effective, and can meet the needs of practical application.

  15. MATHEMATICAL MODELS FOR SOME RADIO-FREQUENCY TRANSMISSION-LINE TRANSFORMERS

    DTIC Science & Technology

    MATRICES(MATHEMATICS), *PHASE SHIFT CIRCUITS, *RADIOFREQUENCY, *TRANSFORMERS, *TRANSMISSION LINES, BROADBAND, DIELECTRIC PROPERTIES, ELECTRICAL IMPEDANCE, FERRITES, IMPEDANCE MATCHING , MATHEMATICAL ANALYSIS.

  16. LineCast: line-based distributed coding and transmission for broadcasting satellite images.

    PubMed

    Wu, Feng; Peng, Xiulian; Xu, Jizheng

    2014-03-01

    In this paper, we propose a novel coding and transmission scheme, called LineCast, for broadcasting satellite images to a large number of receivers. The proposed LineCast matches perfectly with the line scanning cameras that are widely adopted in orbit satellites to capture high-resolution images. On the sender side, each captured line is immediately compressed by a transform-domain scalar modulo quantization. Without syndrome coding, the transmission power is directly allocated to quantized coefficients by scaling the coefficients according to their distributions. Finally, the scaled coefficients are transmitted over a dense constellation. This line-based distributed scheme features low delay, low memory cost, and low complexity. On the receiver side, our proposed line-based prediction is used to generate side information from previously decoded lines, which fully utilizes the correlation among lines. The quantized coefficients are decoded by the linear least square estimator from the received data. The image line is then reconstructed by the scalar modulo dequantization using the generated side information. Since there is neither syndrome coding nor channel coding, the proposed LineCast can make a large number of receivers reach the qualities matching their channel conditions. Our theoretical analysis shows that the proposed LineCast can achieve Shannon's optimum performance by using a high-dimensional modulo-lattice quantization. Experiments on satellite images demonstrate that it achieves up to 1.9-dB gain over the state-of-the-art 2D broadcasting scheme and a gain of more than 5 dB over JPEG 2000 with forward error correction.

  17. Dispersion in Nb microstrip transmission lines at submillimeter wave frequencies

    NASA Technical Reports Server (NTRS)

    Javadi, H. H. S.; Mcgrath, W. R.; Bumble, B.; Leduc, H. G.

    1992-01-01

    We have measured the effects of dispersion on the resonant mode frequencies of open-ended Nb-SiO(x)-Nb microstrip transmission lines over a frequency range from 50 to 800 GHz. Submicron Nb/Al-AlOx/Nb Josephson junctions were used as both voltage-controlled oscillators and detectors to sample the high order modes of the resonators. The resonator modes are equally spaced up to about 550 GHz where the mode spacing start to decrease gradually to a minimum above the gap frequency of about 700 GHz and then increases. Results are in good agreement with the expected theoretical behavior based on the Mattis-Bardeen conductivity of the superconductor line.

  18. Dispersion in Nb microstrip transmission lines at submillimeter wave frequencies

    NASA Technical Reports Server (NTRS)

    Javadi, H. H. S.; Mcgrath, W. R.; Bumble, B.; Leduc, H. G.

    1992-01-01

    We have measured the effects of dispersion on the resonant mode frequencies of open-ended Nb-SiO(x)-Nb microstrip transmission lines over a frequency range from 50 to 800 GHz. Submicron Nb/Al-AlOx/Nb Josephson junctions were used as both voltage-controlled oscillators and detectors to sample the high order modes of the resonators. The resonator modes are equally spaced up to about 550 GHz where the mode spacing start to decrease gradually to a minimum above the gap frequency of about 700 GHz and then increases. Results are in good agreement with the expected theoretical behavior based on the Mattis-Bardeen conductivity of the superconductor line.

  19. Ferroelectric tunable balanced right- and left-handed transmission lines

    NASA Astrophysics Data System (ADS)

    Marteau, Aurélien; Velu, Gabriel; Houzet, Gregory; Burgnies, Ludovic; Lheurette, Eric; Carru, Jean Claude; Lippens, Didier

    2009-01-01

    The tuning of the dispersion characteristics of a balanced composite right- and left-handed transmission lines is demonstrated at centimeter and millimeter wavelengths. To this aim, coplanar waveguides, periodically loaded by interdigitated capacitances and stublike inductances, were fabricated onto a Ba0.5Sr0.5TiO3 ferroelectric thin film. The scattering parameter measurements show that the lines are left handed from 8 to 18 GHz and right handed above. The results are interpreted by the retrieval of the effective permittivity and permeability, which exhibit Drude-like dispersion characteristics with a magnetic plasma frequency, which can be tuned via the voltage-controlled permittivity variation in the BST thin film.

  20. 49 CFR 236.73 - Open-wire transmission line; clearance to other circuits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Open-wire transmission line; clearance to other..., AND APPLIANCES Rules and Instructions: All Systems Wires and Cables § 236.73 Open-wire transmission line; clearance to other circuits. Open-wire transmission line operating at voltage of 750 volts or...

  1. 49 CFR 236.73 - Open-wire transmission line; clearance to other circuits.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Open-wire transmission line; clearance to other..., AND APPLIANCES Rules and Instructions: All Systems Wires and Cables § 236.73 Open-wire transmission line; clearance to other circuits. Open-wire transmission line operating at voltage of 750 volts...

  2. 49 CFR 236.73 - Open-wire transmission line; clearance to other circuits.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Open-wire transmission line; clearance to other..., AND APPLIANCES Rules and Instructions: All Systems Wires and Cables § 236.73 Open-wire transmission line; clearance to other circuits. Open-wire transmission line operating at voltage of 750 volts...

  3. 49 CFR 236.73 - Open-wire transmission line; clearance to other circuits.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Open-wire transmission line; clearance to other..., AND APPLIANCES Rules and Instructions: All Systems Wires and Cables § 236.73 Open-wire transmission line; clearance to other circuits. Open-wire transmission line operating at voltage of 750 volts...

  4. 49 CFR 236.73 - Open-wire transmission line; clearance to other circuits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Open-wire transmission line; clearance to other..., AND APPLIANCES Rules and Instructions: All Systems Wires and Cables § 236.73 Open-wire transmission line; clearance to other circuits. Open-wire transmission line operating at voltage of 750 volts...

  5. 50 CFR 29.21-8 - Electric power transmission line rights-of-way.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false Electric power transmission line rights-of... General Regulations § 29.21-8 Electric power transmission line rights-of-way. By accepting a right-of-way for a power transmission line, the applicant thereby agrees and consents to comply with and be bound...

  6. 50 CFR 29.21-8 - Electric power transmission line rights-of-way.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 50 Wildlife and Fisheries 9 2012-10-01 2012-10-01 false Electric power transmission line rights-of... General Regulations § 29.21-8 Electric power transmission line rights-of-way. By accepting a right-of-way for a power transmission line, the applicant thereby agrees and consents to comply with and be bound...

  7. 50 CFR 29.21-8 - Electric power transmission line rights-of-way.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 50 Wildlife and Fisheries 9 2013-10-01 2013-10-01 false Electric power transmission line rights-of... General Regulations § 29.21-8 Electric power transmission line rights-of-way. By accepting a right-of-way for a power transmission line, the applicant thereby agrees and consents to comply with and be bound...

  8. 50 CFR 29.21-8 - Electric power transmission line rights-of-way.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 8 2011-10-01 2011-10-01 false Electric power transmission line rights-of... General Regulations § 29.21-8 Electric power transmission line rights-of-way. By accepting a right-of-way for a power transmission line, the applicant thereby agrees and consents to comply with and be bound...

  9. 50 CFR 29.21-8 - Electric power transmission line rights-of-way.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 50 Wildlife and Fisheries 9 2014-10-01 2014-10-01 false Electric power transmission line rights-of... General Regulations § 29.21-8 Electric power transmission line rights-of-way. By accepting a right-of-way for a power transmission line, the applicant thereby agrees and consents to comply with and be bound...

  10. Propagation of quasi-static modes in anisotropic transmission lines: application to MIC lines

    SciTech Connect

    Marques, R.; Horno, M.

    1985-10-01

    In this paper, we analyze the field propagation in a general N-conductor transmission line embedded in an inhomogeneous and anisotropic medium, through the series expansion of the field in powers of frequency. The quasi-static approach is deducted as a zero-order approach upon the field and a first-order approach for the propagation constant. It is shown that it is even possible to decompose the field into a sum of propagating modes with a scalar propagation factor. The special case of transmission lines in nonmagnetic media is explicitly considered. A method to find out the mode characteristics of any open planar MIC line with anisotropic dielectric substrates is developed and applied to some MIC structures of interest, specifically broadside edgecoupled microstrips with inverted and noninverted substrates.

  11. Current trends in the application of non-ceramic insulators for transmission & distribution lines subject to contamination

    SciTech Connect

    Riordan, K.C.

    1994-12-31

    Non-Ceramic Insulators (NCI) have been in application for more than 25 years. During this time, manufacturers have worked diligently to improve product designs and polymer materials. Today, the use of Non-Ceramic Polymer insulators is proliferating as Utilities become more confident in this advanced technology. The application advantages of NCI technology are more widely recognized and understood and credibility is growing in the long term service performance of these insulators. Current estimates place the NCI market share as high as 50% of the total US transmission insulator market. Indeed, Reliable Power Products is proud to advise that their insulators have been selected for the first 500 KV-DC transmission line in the USA to use 100% composite polymer insulators. With the combination of Los Angeles Department of Water and Power (Los Angeles to Las Vegas) and Salt River Project (Las Vegas to Phoenix), a total of almost 1,000 Kms. of transmission line will be insulated with Silicone Rubber Polymer Insulators. The total project will include almost 15,000 insulator strings. User confidence is not confined to the USA market. The application of NCI`s by International Utilities has also experienced significant growth. This may be evidenced by EHV installations in South America, Middle East, South Africa, Australia and South East Asia.

  12. Estimating Magnetic Fields of Homes Near Transmission Lines in the California Power Line Study

    PubMed Central

    Vergara, Ximena P.; Kavet, Robert; Crespi, Catherine M.; Hooper, Chris; Silva, J. Michael; Kheifets, Leeka

    2015-01-01

    The California Power Line Study is a case-control study investigating the relation between residences near transmission lines and risk of childhood leukemia. It includes 5788 childhood leukemia cases and 5788 matched primary controls born between 1986 and 2007. We describe the methodology for estimating magnetic fields at study residences as well as for characterizing sources of uncertainty in these estimates. Birth residences of study subjects were geocoded and their distances to transmission lines were ascertained. 302 residences were deemed sufficiently close to transmission lines to have non-zero magnetic fields attributable to the lines. These residences were visited and detailed data, describing the physical configuration and dimensions of the lines contributing to the magnetic field at the residence, were collected. Phasing, loading, and directional load flow data for years of birth and diagnosis for each subject as well as for the day of site visit were obtained from utilities when available; when yearly average load for a particular year was not available, extrapolated values based on expert knowledge and prediction models were obtained. These data were used to estimate the magnetic fields at the center, closest and farthest point of each residence. We found good correlation between calculated fields and spot measurements of fields taken on site during visits. Our modeling strategies yielded similar calculated field estimates, and they were in high agreement with utility extrapolations. Phasing was known for over 90% of the lines. Important sources of uncertainty included a lack of information on the precise location of residences located within apartment buildings or other complexes. Our findings suggest that we were able to achieve high specificity in exposure assessment, which is essential for examining the association between distance to or magnetic fields from power lines and childhood leukemia risk. PMID:26005950

  13. Estimating magnetic fields of homes near transmission lines in the California Power Line Study.

    PubMed

    Vergara, Ximena P; Kavet, Robert; Crespi, Catherine M; Hooper, Chris; Silva, J Michael; Kheifets, Leeka

    2015-07-01

    The California Power Line Study is a case-control study investigating the relation between residences near transmission lines and risk of childhood leukemia. It includes 5788 childhood leukemia cases and 5788 matched primary controls born between 1986 and 2007. We describe the methodology for estimating magnetic fields at study residences as well as for characterizing sources of uncertainty in these estimates. Birth residences of study subjects were geocoded and their distances to transmission lines were ascertained. 302 residences were deemed sufficiently close to transmission lines to have non-zero magnetic fields attributable to the lines. These residences were visited and detailed data, describing the physical configuration and dimensions of the lines contributing to the magnetic field at the residence, were collected. Phasing, loading, and directional load flow data for years of birth and diagnosis for each subject as well as for the day of site visit were obtained from utilities when available; when yearly average load for a particular year was not available, extrapolated values based on expert knowledge and prediction models were obtained. These data were used to estimate the magnetic fields at the center, closest and farthest point of each residence. We found good correlation between calculated fields and spot measurements of fields taken on site during visits. Our modeling strategies yielded similar calculated field estimates, and they were in high agreement with utility extrapolations. Phasing was known for over 90% of the lines. Important sources of uncertainty included a lack of information on the precise location of residences located within apartment buildings or other complexes. Our findings suggest that we were able to achieve high specificity in exposure assessment, which is essential for examining the association between distance to or magnetic fields from power lines and childhood leukemia risk. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Proposal of a gigawatt-class L/Ku dual-band magnetically insulated transmission line oscillator

    NASA Astrophysics Data System (ADS)

    Ju, J.-C.; Fan, Y.-W.; Shu, T.; Zhong, H.-H.

    2014-10-01

    We present a gigawatt (GW)-class magnetically insulated transmission line oscillator (MILO) which is capable of generating dual-band high power microwaves (HPMs). The proposed device, deriving from previously studied complex MILO and dual-frequency MILO, is designed to produce two HPMs in L-band and Ku-band, respectively. It is found in particle-in-cell (PIC) simulation that when the diode voltage is 610 kV, HPMs with frequencies of 1.72 GHz and 14.6 GHz can be achieved with powers of 3.3 GW and 2.4 GW, respectively. The corresponding total power conversion efficiency is approximately 12.8%. Power difference of the two generated HPMs is approximately 1.4 dB, and frequency difference of them reaches a level as high as ˜10 dB.

  15. Conceptual design of 275 kV class high-Tc superconducting cable

    NASA Astrophysics Data System (ADS)

    Mukoyama, S.; Yagi, M.; Fujiwara, N.; Ichikawa, H.

    2010-11-01

    High-temperature superconducting (HTS) cables are expected to be next generation transmission line because of the compact, lightweight, large capacity, and low loss features. Especially, since the YBa2Cu3Ox (YBCO) tape has a high critical current, high magnetic-field property, low AC loss, and low cost, using YBCO tapes for a HTS cable seems to be one of the most promising ways to make the HTS cable attractive. Therefore, YBCO HTS cables have been studied extensively in Japan, the United States, Korea, and many other countries. We now believe that 275 kV class HTS cables will be used for future large capacity lines based on the needs of Japanese transmission networks for bulk transmission power in overhead transmission lines or gas insulated transmission lines (GIL). We started to develop the 275 kV class HTS cable for the new energy and industrial technology development organization (NEDO) project at 2008, and we have studied the applicability and the environmental and economic advantages of the 275 kV cable. This paper will introduce advantages and a conceptual design of the 275 kV HTS cable.

  16. Extragalactic Jets as Electrical Circuits and Transmission Lines

    NASA Astrophysics Data System (ADS)

    Kronberg, Philipp

    2014-10-01

    I describe the first attempt to measure a current in an extended radio galaxy jet: ~1018A at ~50 kpc from the elliptical galaxy's ultra-compact nucleus. This class of jet is known to transport its magnetic energy ``intact'', up to supragalactic scales. I discuss plasma parameters for 3C303 and recent attempts to measure its jet axial current. I discuss analogies with both electrical circuits, - and transmission lines. Power is delivered into a ``load'', whose impedance, Z, is close to that of free space, and the jet power flow I2 Z is ~1035 erg s-1 - broadly consistent with astronomically measured total power outputs, luminosities and lifetimes of AGN-powered radio lobes.The current and power levels are also consistent with SMBH accretion disk model predictions by Stirling Colgate, H. Li, V. Pariev, J. Finn, and others, beginning with Lovelace 1976 (Nature). A further analogy with transmission lines shows how the supragalactic power flows can be disrupted by a complex impedance in the ``circuit.'' Reactive components in space, i.e. a complex Z, can disrupt, reflect or deflect the power flow. This could explain the wide variety of magneto-plasma configurations seen in these systems. Funded by NSERC Discovery Grant A5713.

  17. Single-wire radio frequency transmission lines in biological tissue

    NASA Astrophysics Data System (ADS)

    Besnoff, Jordan S.; Reynolds, Matthew S.

    2015-05-01

    We present an approach for implanting radio frequency transmission lines in biological tissue, using a single insulated wire surrounded by tissue as a variant of the Goubau single-wire transmission line (SWTL) in air. We extend the Goubau SWTL model to include SWTLs surrounded by lossy dielectrics such as tissue by assuming a propagating mode component in the tissue. We show that a thin wire of radius 63.5 μ m , coated with biocompatible fluorinated ethylene propylene dielectric, exhibits a measured loss of only 1 dB/cm at a frequency of 915 MHz. The model fit to the measured insertion loss is within ±0.3 dB/cm across the 100 MHz to 3 GHz band. This SWTL presents excellent impedance matching to 50 Ω as evidenced by a measured median return loss better than 10 dB across the 100 MHz to 3 GHz range. This approach represents an alternative to near-field magnetic coupling for implanted systems where tissue displacement by a single, thin wire can be tolerated.

  18. Study on a discal TEM-TE11 mode converter loaded high-efficiency magnetically insulated transmission line oscillator.

    PubMed

    Zhang, Xiaoping; Yuan, Chengwei; Li, Yangmei; Zhang, Jiande; Zhang, Qiang

    2015-12-01

    An integrative high power microwave device is proposed, which consists of a high-efficiency L-band Magnetically Insulated Transmission Line Oscillator (MILO) and a discal TEM-TE11 mode converter. The MILO with a shrunken load composed of a step-like cathode and a ladder-like beam collector can generate a 1.58 GHz, 5.7 GW microwave with the efficiency of 20.8% at the diode voltage of 560 kV in simulation. The discal converter utilizes a pair of sectorial two-double radial waveguides and a pair of sectorial cross section waveguides to adjust the phase-difference and realizes the mode conversion in a length of less than half wavelength at 1.58 GHz. In the preliminary experiment, the proposed device generates over 2 GW, 1.575 GHz microwave with the pulse duration of over 50 ns in a 420 kV diode voltage; the corresponding efficiency is 14.9%; the radiation pattern is the ideal TE11 mode.

  19. Study on a discal TEM-TE{sub 11} mode converter loaded high-efficiency magnetically insulated transmission line oscillator

    SciTech Connect

    Zhang, Xiaoping Yuan, Chengwei; Li, Yangmei; Zhang, Jiande; Zhang, Qiang

    2015-12-15

    An integrative high power microwave device is proposed, which consists of a high-efficiency L-band Magnetically Insulated Transmission Line Oscillator (MILO) and a discal TEM–TE{sub 11} mode converter. The MILO with a shrunken load composed of a step-like cathode and a ladder-like beam collector can generate a 1.58 GHz, 5.7 GW microwave with the efficiency of 20.8% at the diode voltage of 560 kV in simulation. The discal converter utilizes a pair of sectorial two-double radial waveguides and a pair of sectorial cross section waveguides to adjust the phase-difference and realizes the mode conversion in a length of less than half wavelength at 1.58 GHz. In the preliminary experiment, the proposed device generates over 2 GW, 1.575 GHz microwave with the pulse duration of over 50 ns in a 420 kV diode voltage; the corresponding efficiency is 14.9%; the radiation pattern is the ideal TE{sub 11} mode.

  20. Study on a discal TEM-TE11 mode converter loaded high-efficiency magnetically insulated transmission line oscillator

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaoping; Yuan, Chengwei; Li, Yangmei; Zhang, Jiande; Zhang, Qiang

    2015-12-01

    An integrative high power microwave device is proposed, which consists of a high-efficiency L-band Magnetically Insulated Transmission Line Oscillator (MILO) and a discal TEM-TE11 mode converter. The MILO with a shrunken load composed of a step-like cathode and a ladder-like beam collector can generate a 1.58 GHz, 5.7 GW microwave with the efficiency of 20.8% at the diode voltage of 560 kV in simulation. The discal converter utilizes a pair of sectorial two-double radial waveguides and a pair of sectorial cross section waveguides to adjust the phase-difference and realizes the mode conversion in a length of less than half wavelength at 1.58 GHz. In the preliminary experiment, the proposed device generates over 2 GW, 1.575 GHz microwave with the pulse duration of over 50 ns in a 420 kV diode voltage; the corresponding efficiency is 14.9%; the radiation pattern is the ideal TE11 mode.

  1. Pattern Recognition Application of Support Vector Machine for Fault Classification of Thyristor Controlled Series Compensated Transmission Lines

    NASA Astrophysics Data System (ADS)

    Yashvantrai Vyas, Bhargav; Maheshwari, Rudra Prakash; Das, Biswarup

    2016-06-01

    Application of series compensation in extra high voltage (EHV) transmission line makes the protection job difficult for engineers, due to alteration in system parameters and measurements. The problem amplifies with inclusion of electronically controlled compensation like thyristor controlled series compensation (TCSC) as it produce harmonics and rapid change in system parameters during fault associated with TCSC control. This paper presents a pattern recognition based fault type identification approach with support vector machine. The scheme uses only half cycle post fault data of three phase currents to accomplish the task. The change in current signal features during fault has been considered as discriminatory measure. The developed scheme in this paper is tested over a large set of fault data with variation in system and fault parameters. These fault cases have been generated with PSCAD/EMTDC on a 400 kV, 300 km transmission line model. The developed algorithm has proved better for implementation on TCSC compensated line with its improved accuracy and speed.

  2. Smaller-loss planar SPP transmission line than conventional microstrip in microwave frequencies

    PubMed Central

    Zhang, Hao Chi; Zhang, Qian; Liu, Jun Feng; Tang, Wenxuan; Fan, Yifeng; Cui, Tie Jun

    2016-01-01

    Transmission line is a basic component in all passive devices, integrated circuits, and systems. Microstrip is the most popular transmission line in the microwave and millimeter-wave frequencies, and has been widely used in current electronic devices, circuits, and systems. One of the important issues to be solved in such applications is the relatively large transmission loss of microstrip. Here, we propose a method to reduce the loss of microwave transmission line based on the designable wavenumber of spoof surface plasmon polaritons (SPPs). Using this characteristic, we analyze and experimentally demonstrate the low-loss feature of the SPP transmission line through the perturbation method and S-parameter measurements, respectively. Both simulation and experimental results show that the SPP transmission line has much smaller transmission loss than traditional microstrip with the same size in the microwave frequencies. Hence, the spoof SPP transmission line may make a big step forward in the low-loss circuits and systems. PMID:26983911

  3. Smaller-loss planar SPP transmission line than conventional microstrip in microwave frequencies.

    PubMed

    Zhang, Hao Chi; Zhang, Qian; Liu, Jun Feng; Tang, Wenxuan; Fan, Yifeng; Cui, Tie Jun

    2016-03-17

    Transmission line is a basic component in all passive devices, integrated circuits, and systems. Microstrip is the most popular transmission line in the microwave and millimeter-wave frequencies, and has been widely used in current electronic devices, circuits, and systems. One of the important issues to be solved in such applications is the relatively large transmission loss of microstrip. Here, we propose a method to reduce the loss of microwave transmission line based on the designable wavenumber of spoof surface plasmon polaritons (SPPs). Using this characteristic, we analyze and experimentally demonstrate the low-loss feature of the SPP transmission line through the perturbation method and S-parameter measurements, respectively. Both simulation and experimental results show that the SPP transmission line has much smaller transmission loss than traditional microstrip with the same size in the microwave frequencies. Hence, the spoof SPP transmission line may make a big step forward in the low-loss circuits and systems.

  4. Smaller-loss planar SPP transmission line than conventional microstrip in microwave frequencies

    NASA Astrophysics Data System (ADS)

    Zhang, Hao Chi; Zhang, Qian; Liu, Jun Feng; Tang, Wenxuan; Fan, Yifeng; Cui, Tie Jun

    2016-03-01

    Transmission line is a basic component in all passive devices, integrated circuits, and systems. Microstrip is the most popular transmission line in the microwave and millimeter-wave frequencies, and has been widely used in current electronic devices, circuits, and systems. One of the important issues to be solved in such applications is the relatively large transmission loss of microstrip. Here, we propose a method to reduce the loss of microwave transmission line based on the designable wavenumber of spoof surface plasmon polaritons (SPPs). Using this characteristic, we analyze and experimentally demonstrate the low-loss feature of the SPP transmission line through the perturbation method and S-parameter measurements, respectively. Both simulation and experimental results show that the SPP transmission line has much smaller transmission loss than traditional microstrip with the same size in the microwave frequencies. Hence, the spoof SPP transmission line may make a big step forward in the low-loss circuits and systems.

  5. A study of electric power transmission lines for use on the lunar surface

    NASA Technical Reports Server (NTRS)

    Gordon, Lloyd B.; Gaustad, Krista L.

    1991-01-01

    Analytical models have been developed to study the operating characteristics of electrical transmission lines for use on the lunar surface. Important design considerations for a transmission line operating on the lunar surface are mass, temperature, and efficiency. Transmission line parameters which impact these considerations include voltage, power loss, and waveform. The electrical and thermal models developed are used to calculate transmission line mass, size, and temperature as a function of voltage, geometry, waveform, location, and efficiency. The analyses include ac and dc for above and below ground operation. Geometries studied include a vacuum-insulated, two-wire transmission line and a solid-dielectric insulated, coaxial transmission line. A brief discussion of design considerations and the models developed is followed by results for parameter studies for both dc and ac transmission lines.

  6. A study of electric power transmission lines for use on the lunar surface

    NASA Technical Reports Server (NTRS)

    Gordon, Lloyd B.; Gaustad, Krista L.

    1991-01-01

    Analytical models have been developed to study the operating characteristics of electrical transmission lines for use on the lunar surface. Important design considerations for a transmission line operating on the lunar surface are mass, temperature, and efficiency. Transmission line parameters which impact these considerations include voltage, power loss, and waveform. The electrical and thermal models developed are used to calculate transmission line mass, size, and temperature as a function of voltage, geometry, waveform, location, and efficiency. The analyses include ac and dc for above and below ground operation. Geometries studied include a vacuum-insulated, two-wire transmission line and a solid-dielectric insulated, coaxial transmission line. A brief discussion of design considerations and the models developed is followed by results for parameter studies for both dc and ac transmission lines.

  7. Material selection of a ferrimagnetic loaded coaxial delay line for phasing gyromagnetic nonlinear transmission lines.

    PubMed

    Johnson, J M; Reale, D V; Cravey, W H; Garcia, R S; Barnett, D H; Neuber, A A; Dickens, J C; Mankowski, J J

    2015-08-01

    Implementing nonlinear transmission line (NLTL) technology in the design of a high power microwave source has the benefits of producing a comparatively small and lightweight solid-state system where the emission frequency is easily tuned. Usually, smaller in physical size, single NLTLs may produce significantly less power than its vacuum based counterparts. However, combining individual NLTL outputs electrically or in free-space is an attractive solution to achieve greater output power. This paper discusses a method for aligning a four element NLTL antenna array with coaxial geometry using easily adjustable temporal delay lines. These delay lines, sometimes referred to as pulse shock lines or pulse sharpening lines, are placed serially in front of the main NLTL line. The propagation velocity in each delay line is set by the voltage amplitude of an incident pulse as well as the magnetic field bias. Each is adjustable although for the system described in this paper, the voltage is held constant while the bias is changed through applying an external DC magnetic field of varying magnitude. Three different ferrimagnetic materials are placed in the temporal delay line to evaluate which yields the greatest range of electrical delay with the least amount of variability from consecutive shots.

  8. Kv5, Kv6, Kv8, and Kv9 subunits: No simple silent bystanders

    PubMed Central

    2016-01-01

    Members of the electrically silent voltage-gated K+ (Kv) subfamilies (Kv5, Kv6, Kv8, and Kv9, collectively identified as electrically silent voltage-gated K+ channel [KvS] subunits) do not form functional homotetrameric channels but assemble with Kv2 subunits into heterotetrameric Kv2/KvS channels with unique biophysical properties. Unlike the ubiquitously expressed Kv2 subunits, KvS subunits show a more restricted expression. This raises the possibility that Kv2/KvS heterotetramers have tissue-specific functions, making them potential targets for the development of novel therapeutic strategies. Here, I provide an overview of the expression of KvS subunits in different tissues and discuss their proposed role in various physiological and pathophysiological processes. This overview demonstrates the importance of KvS subunits and Kv2/KvS heterotetramers in vivo and the importance of considering KvS subunits and Kv2/KvS heterotetramers in the development of novel treatments. PMID:26755771

  9. Fuzzy logic based on-line fault detection and classification in transmission line.

    PubMed

    Adhikari, Shuma; Sinha, Nidul; Dorendrajit, Thingam

    2016-01-01

    This study presents fuzzy logic based online fault detection and classification of transmission line using Programmable Automation and Control technology based National Instrument Compact Reconfigurable i/o (CRIO) devices. The LabVIEW software combined with CRIO can perform real time data acquisition of transmission line. When fault occurs in the system current waveforms are distorted due to transients and their pattern changes according to the type of fault in the system. The three phase alternating current, zero sequence and positive sequence current data generated by LabVIEW through CRIO-9067 are processed directly for relaying. The result shows that proposed technique is capable of right tripping action and classification of type of fault at high speed therefore can be employed in practical application.

  10. A computer code to calculate line by line atmospheric transmission spectra on a microcomputer

    NASA Technical Reports Server (NTRS)

    Safren, H. G.

    1987-01-01

    A computer program is described which calculates line by line atmospheric transmission spectra on a microcomputer. Radiance calculations are not included. The program is written in FORTRAN and could be modified to run on a microcomputer other than the one on which it was implemented, except that the plotting routine would have to be replaced. The program is based on the 1978 Air Force Geophysics Laboratory LASER routine, and uses absorption line data from the 1982 update of the AFGL Atmospheric Absorption Line Parameters Compilation; segments of needed line data are taken from the tape, preprocessed into the form used by the program and stored on floppy disks. The program calculates transmission spectra over a variety of paths and spanning an arbitrarily chosen wavelength or frequency range; the path may be chosen to be horizontal, vertical or slanted at any zenith angle, and may extend between any two altitudes between 0 and 15 km. Aerosol effects are included, presently based on the 1976 Shettle and Fenn models, plus some molecular continuum effects and Rayleigh scattering.

  11. Effect of temperature on beam damage of asbestos fibers in the transmission electron microscope (TEM) at 100kV.

    PubMed

    Martin, Joannie; Beauparlant, Martin; Sauvé, Sébastien; L'Espérance, Gilles

    2017-03-01

    Damage to asbestos fibers by the transmission electron microscope (TEM) electron beam is a known limitation of this powerful method of analysis. Although it is often considered only in terms of loss of crystallinity, recent studies have shown that the damage may also change the elemental composition of fibers, thus causing significant identification errors. In this study, the main objective was to assess whether temperature is a factor influencing damage to asbestos fibers and, if so, how it can be used to minimize damage. It was found that lowering the temperature to 123K can inhibit, for a given time, the manifestation of the damage. The significant decrease of atom diffusion at low temperature momentarily prevents mass loss, greatly reducing the possibility of misidentification of anthophyllite asbestos fibers. The results obtained in this study strongly suggest that the predominant mechanism damage is probably related to the induced-electric-field model relegating radiolysis to the status of a subsidiary damage mechanism. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Management of localized energy in discrete nonlinear transmission lines

    NASA Astrophysics Data System (ADS)

    Sato, M.; Yasui, S.; Kimura, M.; Hikihara, T.; Sievers, A. J.

    2007-11-01

    The manipulation of locked intrinsic localized modes/discrete breathers is studied experimentally in nonlinear electric transmission line arrays. Introducing a static lattice impurity in the form of a capacitor, resistor or inductor has been used both to seed or destroy and attract or repel these localized excitations. In a nonlinear di-element array counter propagating short electrical pulses traveling in the acoustic branch are used to generate a stationary intrinsic localized mode in the optic branch at any particular lattice site. By changing the pulse polarity the same localized excitation can be eliminated demonstrating that the dynamical impurity associated with the propagating electrical pulse in the acoustic branch can trigger optical localized mode behavior.

  13. Monolithic high voltage nonlinear transmission line fabrication process

    DOEpatents

    Cooper, G.A.

    1994-10-04

    A process for fabricating sequential inductors and varistor diodes of a monolithic, high voltage, nonlinear, transmission line in GaAs is disclosed. An epitaxially grown laminate is produced by applying a low doped active n-type GaAs layer to an n-plus type GaAs substrate. A heavily doped p-type GaAs layer is applied to the active n-type layer and a heavily doped n-type GaAs layer is applied to the p-type layer. Ohmic contacts are applied to the heavily doped n-type layer where diodes are desired. Multiple layers are then either etched away or Oxygen ion implanted to isolate individual varistor diodes. An insulator is applied between the diodes and a conductive/inductive layer is thereafter applied on top of the insulator layer to complete the process. 6 figs.

  14. Monolithic high voltage nonlinear transmission line fabrication process

    DOEpatents

    Cooper, Gregory A.

    1994-01-01

    A process for fabricating sequential inductors and varactor diodes of a monolithic, high voltage, nonlinear, transmission line in GaAs is disclosed. An epitaxially grown laminate is produced by applying a low doped active n-type GaAs layer to an n-plus type GaAs substrate. A heavily doped p-type GaAs layer is applied to the active n-type layer and a heavily doped n-type GaAs layer is applied to the p-type layer. Ohmic contacts are applied to the heavily doped n-type layer where diodes are desired. Multiple layers are then either etched away or Oxygen ion implanted to isolate individual varactor diodes. An insulator is applied between the diodes and a conductive/inductive layer is thereafter applied on top of the insulator layer to complete the process.

  15. Gas insulated transmission line having low inductance intercalated sheath

    DOEpatents

    Cookson, Alan H.

    1978-01-01

    A gas insulated transmission line including an outer sheath, an inner conductor disposed within the outer sheath, and an insulating gas between the inner conductor and the outer sheath. The outer sheath comprises an insulating tube having first and second ends, and having interior and exterior surfaces. A first electrically conducting foil is secured to the interior surface of the insulating tube, is spirally wound from one tube end to the second tube end, and has a plurality of overlapping turns. A second electrically conducting foil is secured to the exterior surface of the insulating tube, and is spirally wound in the opposite direction from the first electrically conducting foil. By winding the foils in opposite directions, the inductances within the intercalated sheath will cancel each other out.

  16. Acoustic solitons in waveguides with Helmholtz resonators: transmission line approach.

    PubMed

    Achilleos, V; Richoux, O; Theocharis, G; Frantzeskakis, D J

    2015-02-01

    We report experimental results and study theoretically soliton formation and propagation in an air-filled acoustic waveguide side loaded with Helmholtz resonators. We propose a theoretical modeling of the system, which relies on a transmission-line approach, leading to a nonlinear dynamical lattice model. The latter allows for an analytical description of the various soliton solutions for the pressure, which are found by means of dynamical systems and multiscale expansion techniques. These solutions include Boussinesq-like and Korteweg-de Vries pulse-shaped solitons that are observed in the experiment, as well as nonlinear Schrödinger envelope solitons, that are predicted theoretically. The analytical predictions are in excellent agreement with direct numerical simulations and in qualitative agreement with the experimental observations.

  17. Terahertz Quantum-Cascade Transmission-Line Metamaterials

    NASA Astrophysics Data System (ADS)

    Tavallaee, Amir Ali

    Terahertz quantum-cascade (QC) lasers operating at 0.6 - 5 THz (λ ˜ 60 - 500 µm) are poised to become the dominant solid-state sources of continuous-wave (cw) far-infrared radiation enabling applications in terahertz spectroscopy, imaging, and sensing. QC-lasers are the longest wavelength semiconductor laser sources in which terahertz gain is obtained from electronic intersubband radiative transitions in GaAs/AlGaAs heterostructure quantum wells. Since their invention in 2001, rapid development has enabled demonstration of cw powers greater than 100 mW. However, challenges still remain in the areas of operating temperature, laser efficiency and power, and beam quality to name a few. The highest-temperature operation of terahertz quantum-cascade lasers (200 K pulsed, 117 K cw) depends on the use of a low-loss "metal-metal" waveguide where the active gain material is sandwiched between two metal cladding layers; a technique similar, in concept, to microstrip transmission line technology at microwave frequencies. Due to the subwavelength transverse dimensions of the metal-metal waveguide, however, obtaining a directive beam pattern and efficient out-coupling of THz power is non-trivial. This thesis reports the demonstration of a one-dimensional waveguide for terahertz quantum-cascade lasers that acts as a leaky-wave antenna and tailors laser radiation in one dimension to a directional beam. This scheme adapts microwave transmission-line metamaterial concepts to a planar structure realized in terahertz metal-metal waveguide technology and is fundamentally different from distributed feedback/photonic crystal structures that work based on Bragg scattering of propagating modes. The leaky-wave metamaterial antenna operates based on a propagating mode with an effective phase index smaller than unity such that it radiates in the surface direction via a leaky-wave mechanism. Surface emission (˜ 40° from broadside) with a single directive beam (FWHM ˜ 15°) at 2.74 THz

  18. Transmission line corona losses under hoar frost conditions

    SciTech Connect

    Lahti, K.; Nousiainen, K.; Lahtinen, M.

    1997-04-01

    Transmission line corona losses under hoar frost conditions were studied in the climate room of the high voltage laboratory of Tampere University of Technology. The measurements were performed using a coaxial measurement arrangement with different bundle and conductor types. The effects of conductor and bundle type, temperature, applied voltage and hoar frost thickness on corona losses were investigated. A two-conductor bundle had corona losses about 2.5--5 times higher than a three-conductor bundle. Relatively thin hoar frosts were used in the tests. Even the thinnest hoar frost resulted in remarkable corona losses and the losses were very sensitive to changes in the hoar frost thickness. The ambient temperature had a strong influence on the measured losses.

  19. U. S. transmission lines moving to comply with 636

    SciTech Connect

    Not Available

    1992-07-20

    This paper reports that interstate gas pipelines continue taking steps to comply with the Federal Energy Regulatory Commission's Order 636. Implementation of the order, as currently written, would mean increased administrative chores for U.S. transmission lines. In the latest announcements: Algonquin Gas Transmission Co. (AGT), Boston, became the second interstate pipeline company to submit an Order 636 compliance filing. Implementation of the filing, expected Nov. 1, would unbundle AGT's sales and storage services at upstream system receipt points. The filing outlines new services, operating conditions, and rates AGT plans to offer customers under 636. FERC approved anew services settlement pending since March 1991, enabling Northern Natural Gas Co., Omaha, to take a step toward unbundling system services and enhancing equal access for all suppliers. FERC approved the settlement with minor changes for a interim period while Northern finishes its 636 restructuring proposal. The company will accept the modified settlement as an interim step but ask FERC to reconsider some of the changes.

  20. Evaluation of Fibre Lifetime in Optical Ground Wire Transmission Lines

    NASA Astrophysics Data System (ADS)

    Grunvalds, R.; Ciekurs, A.; Porins, J.; Supe, A.

    2017-06-01

    In the research, measurements of polarisation mode dispersion of two OPGWs (optical ground wire transmission lines), in total four fibres, have been carried out, and the expected lifetime of the infrastructure has been assessed on the basis of these measurements. The cables under consideration were installed in 1995 and 2011, respectively. Measurements have shown that polarisation mode dispersion values for cable installed in 1995 are four times higher than that for cable installed in 2011, which could mainly be explained by technological differences in fibre production and lower fibre polarisation mode dispersion requirements in 1995 due to lack of high-speed (over 10 Gbit/s) optical transmission systems. The calculation methodology of non-refusal work and refusal probabilities, using the measured polarisation mode dispersion parameters, is proposed in the paper. Based on reliability calculations, the expected lifetime is then predicted, showing that all measured fibres most likely will be operational within minimum theoretical service life of 25 years accepted by the industry.

  1. Research on cost control and management in high voltage transmission line construction

    NASA Astrophysics Data System (ADS)

    Xu, Xiaobin

    2017-05-01

    Enterprises. The cost control is of vital importance to the construction enterprises. It is the key to the profitability of the transmission line project, which is related to the survival and development of the electric power construction enterprises. Due to the long construction line, complex and changeable construction terrain as well as large construction costs of transmission line, it is difficult for us to take accurate and effective cost control on the project implementation of entire transmission line. Therefore, the cost control of transmission line project is a complicated and arduous task. It is of great theoretical and practical significance to study the cost control scheme of transmission line project by a more scientific and efficient way. Based on the characteristics of the construction project of the transmission line project, this paper analyzes the construction cost structure of the transmission line project and the current cost control problem of the transmission line project, and demonstrates the necessity and feasibility of studying the cost control scheme of the transmission line project more accurately. In this way, the dynamic cycle cost control process including plan, implementation, feedback, correction, modification and re-implement is achieved to realize the accurate and effective cost control of entire electric power transmission line project.

  2. 76 FR 21338 - Reopening of Scoping Period for the Northern Pass Transmission Line Project Environmental Impact...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-15

    ... Reopening of Scoping Period for the Northern Pass Transmission Line Project Environmental Impact Statement... (DOE) is reopening the public scoping period for the Northern Pass Transmission Line Project... environmental impacts from its proposal to grant a Presidential Permit to Northern Pass Transmission, LLC,...

  3. 49 CFR 192.711 - Transmission lines: General requirements for repair procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Transmission lines: General requirements for... Maintenance § 192.711 Transmission lines: General requirements for repair procedures. (a) Temporary repairs..., imperfection, or damage that impairs its serviceability is found in a segment of steel transmission...

  4. 49 CFR 192.711 - Transmission lines: General requirements for repair procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: General requirements for... Maintenance § 192.711 Transmission lines: General requirements for repair procedures. (a) Temporary repairs..., imperfection, or damage that impairs its serviceability is found in a segment of steel transmission...

  5. Innovation on Energy Power Technology(5)A History on Development of 500kV XLPE Cable for Long Distance Power Transmission

    NASA Astrophysics Data System (ADS)

    Tanaka, Hideo

    The history in the development of 500kV XLPE cable, especially the struggles in the development work and field application by the engineers has been described in this article. Power cables are one of the large-sized industrial products; however, 500kV XLPE cable requires very sophisticated and fine technologies in its realization. On the way to the goal of its realization, engineers had many struggles against never-experienced subjects and finally they could overcome such difficulties. Field application of 500kV XLPE cable, including installation and jointing, had been established based on the much effort of many engineers.

  6. The Possibility of Decreasing 50-Hz Electric Field Exposure near 400-kV Power Lines with Arc Flash Personal Protective Equipment

    PubMed Central

    Korpinen, Leena; Pirkkalainen, Herkko; Heiskanen, Timo; Pääkkönen, Rauno

    2016-01-01

    Various guidelines for the protection of human beings against possible adverse effects resulting from exposure to electromagnetic fields (EMFs) have been published with a view towards continual improvement; therefore, decreasing exposure is an important research area. The aim of this study was to investigate the possibility of decreasing electric field exposure with arc flash rated personal protective equipment (PPE), which in this case was a set of coveralls, and to compare the measurement results to calculations using the helmet-mask measuring system. We collected the data under a 400-kV power line. The test person stood on isolated aluminum paper, and the current between the ground and the aluminum paper was measured. When the test subject wore the arc flash PPE, the current to the ground was only 9.5% of the current measured when wearing normal clothes, which represents a clear decrease in exposure. PMID:27669278

  7. The Possibility of Decreasing 50-Hz Electric Field Exposure near 400-kV Power Lines with Arc Flash Personal Protective Equipment.

    PubMed

    Korpinen, Leena; Pirkkalainen, Herkko; Heiskanen, Timo; Pääkkönen, Rauno

    2016-09-23

    Various guidelines for the protection of human beings against possible adverse effects resulting from exposure to electromagnetic fields (EMFs) have been published with a view towards continual improvement; therefore, decreasing exposure is an important research area. The aim of this study was to investigate the possibility of decreasing electric field exposure with arc flash rated personal protective equipment (PPE), which in this case was a set of coveralls, and to compare the measurement results to calculations using the helmet-mask measuring system. We collected the data under a 400-kV power line. The test person stood on isolated aluminum paper, and the current between the ground and the aluminum paper was measured. When the test subject wore the arc flash PPE, the current to the ground was only 9.5% of the current measured when wearing normal clothes, which represents a clear decrease in exposure.

  8. DNA damage, cell kinetics and ODC activities studied in CBA mice exposed to electromagnetic fields generated by transmission lines.

    PubMed

    Svedenstål, B M; Johanson, K J; Mattsson, M O; Paulsson, L E

    1999-01-01

    CBA mice were exposed outdoors to 50 Hz electromagnetic fields (EMF), with a flux density of about 8 microT rms (root mean square), generated by a 220 kV transmission line. Assays were performed in order to investigate, the possible genotoxic effects after 11, 20 and 32 days of exposure, as well as the effects on body weight, leukocytes, erythrocytes, and the level of ornithine decarboxylase (ODC) activity in spleen and testis. DNA migration was studied on brain cells by single cell electrophoresis (comet assay). After 32 days of exposure a highly significant change of the tail/head ratio of the comets was observed (p < 0.001), showing DNA-damage. Further, a decreased number of mononuclear leukocytes (0.02 < p < 0.05) was observed in mice EMF-exposed for 20 days. In summary, our data indicate that transmission lines of this type may induce genotoxic effects in mice, seen as changes in the DNA migration. These results might have an important implication for health effects.

  9. Polar On-Line Acquisition Relay and Transmission System (POLARATS)

    SciTech Connect

    Yuracko, K.

    2004-07-15

    POLARATS (Polar On-Line Acquisition Relay And Transmission System) is being developed by YAHSGS LLC (YAHSGS) and Oak Ridge National Laboratory (ORNL) to provide remote, unattended monitoring of environmental parameters under harsh environmental conditions. In particular, instrumental design and engineering is oriented towards protection of human health in the Arctic, and with the additional goal of advancing Arctic education and research. POLARATS will obtain and transmit environmental data from hardened monitoring devices deployed in locations important to understanding atmospheric and aquatic pollutant migration as it is biomagnified in Arctic food chains. An Internet- and personal computer (PC)-based educational module will provide real time sensor data, on-line educational content, and will be integrated with workbooks and textbooks for use in middle and high school science programs. The educational elements of POLARATS include an Internet-based educational module that will instruct students in the use of the data and how those data fit into changing Arctic environments and food chains. POLARATS will: (1) Enable students, members of the community, and scientific researchers to monitor local environmental conditions in real time over the Internet; and (2) Provide additional educational benefits through integration with middle- and high-school science curricula. Information will be relayed from POLARATS devices to classrooms and libraries along with custom-designed POLARATS teaching materials that will be integrated into existing curricula to enhance the educational benefits realized from the information obtained.

  10. LOSS ESTIMATE FOR ITER ECH TRANSMISSION LINE INCLUDING MULTIMODE PROPAGATION

    SciTech Connect

    Shapiro, Michael; Bigelow, Tim S; Caughman, John B; Rasmussen, David A

    2010-01-01

    The ITER electron cyclotron heating (ECH) transmission lines (TLs) are 63.5-mm-diam corrugated waveguides that will each carry 1 MW of power at 170 GHz. The TL is defined here as the corrugated wave guide system connecting the gyrotron mirror optics unit (MO U) to the entrance of the ECH launcher and includes miter bends and other corrugated wave guide components. The losses on the ITER TL have been calculated for four possible cases corresponding to having HE(11) mode purity at the input of the TL of 100, 97, 90, and 80%. The losses due to coupling, ohmic, and mode conversion loss are evaluated in detail using a numerical code and analytical approaches. Estimates of the calorimetric loss on the line show that the output power is reduced by about 5, +/- 1% because of ohmic loss in each of the four cases. Estimates of the mode conversion loss show that the fraction of output power in the HE(11) mode is similar to 3% smaller than the fraction of input power in the HE(11) mode. High output mode purity therefore can be achieved only with significantly higher input mode purity. Combining both ohmic and mode conversion loss, the efficiency of the TL from the gyrotron MOU to the ECH launcher can be roughly estimated in theory as 92% times the fraction of input power in the HE(11) mode.

  11. Vacuum transmission lines for pulse sharpening and diagnostics applications

    SciTech Connect

    Di Capua, M.S.; Goerz, D.A.; Freytag, E.K.

    1987-06-01

    We investigated the propagation of MV electrical pulses along coaxial transmission lines (TL) in vacuum with network simulations and experiments. One goal was to establish how well a 3 m-long TL would sharpen the output pulse of a relativistic electron beam accelerator. Sharpening occurs as the cathode of the TL emits electrons and the current flow forces the TL into magnetic cut-off. The other goal was to determine how well field emission must be suppressed in a TL to avoid distortion of a propagating pulse. Simulations predict a four-fold risetime improvement (8 ns to 2 ns) through magnetic insulation in a TL with an electrical length (10 ns) comparable to the risetime of the input pulse. In the laboratory we have shown a five-fold improvement (15 to 3 ns) with a velvet covered 3-m line and a 7.5 fold improvement (2 ns) when a vacuum flashover switch was incorporated between the first third and the last two thirds of the TL. Simple arguments and TL simulations suggest that even a small fraction (1 or 2%) of Child-Langmuir (CL) space charge limited emission will distort a propagating voltage pulse. This result is of particular importance when the TL is part of a voltage diagnostic system.

  12. Electric Power High-Voltage Transmission Lines: Design Options, Cost, and Electric and Magnetic Field Levels

    SciTech Connect

    Stoffel, J. B.; Pentecost, E. D.; Roman, R. D.; Traczyk, P. A.

    1994-11-01

    The aim of this report is to provide background information about (1) the electric and magnetic fields (EMFs) of high-voltage transmission lines at typical voltages and line configurations and (2) typical transmission line costs to assist preparers and reviewers of the section on alternatives in environmental documents. This report will give the reviewing individual a better appreciation of the factors affecting EMF strengths near high-voltage transmission lines and the approaches that might be used to reduce EMF impacts on humans and other biological species in the vicinity of high-voltage overhead or underground alternating-current (ac) or direct-current (dc) transmission lines.

  13. Structural health monitoring of compression connectors for overhead transmission lines

    SciTech Connect

    Wang, Hong; Wang, Jy-An John; Swindeman, Joseph P; Ren, Fei; Chan, John

    2017-01-01

    Two-stage aluminum conductor steel-reinforced (ACSR) compression connectors are extensively used in US overhead transmission lines. The connectors are made by crimping a steel sleeve onto a steel core and an aluminum sleeve over aluminum conductive strands. The connectors are designed to operate at temperatures up to 125 C, but their performance is increasingly degrading because of overloading of lines. Currently, electric utilities conduct routine line inspections using thermal and electrical measurements. However, information about the structural integrity of connectors cannot be obtained. In this work, structural health monitoring (SHM) of compression connectors was studied using electromechanical impedance (EMI) analysis. Lead zirconate titanate (PZT)-5A was identified as a smart material for SHM. A flexible high-temperature bonding layer was used to address challenges in PZT integration due to a significant difference in the coefficients of thermal expansion of PZT and the aluminum substrate. The steel joint on the steel core was investigated because it is responsible for the ultimate tensile strength of the connector. Tensile testing was used to create structural damage to the joint, or steel core pullout, and thermal cycling introduced additional structural perturbations. EMI measurements were conducted between the tests. The root mean square deviation (RMSD) of EMI was identified as a damage index. The use of steel joints has been shown to enable SHM under simulated conditions. The EMI signature is sensitive to variations in structural conditions. RMSD can be correlated to the structural health of a connector and has potential for use in the SHM and structural integrity evaluation.

  14. Structural health monitoring of compression connectors for overhead transmission lines

    NASA Astrophysics Data System (ADS)

    Wang, Hong; Wang, Jy-An John; Swindeman, Joseph P.; Ren, Fei; Chan, John

    2017-04-01

    Two-stage aluminum conductor steel-reinforced (ACSR) compression connectors are extensively used in US overhead transmission lines. The connectors are made by crimping a steel sleeve onto a steel core and an aluminum sleeve over electrical conducting aluminum strands. The connectors are designed to operate at temperatures up to 125°C, but their performance is increasingly degrading because of overloading of lines. Currently, electric utilities conduct routine line inspections using thermal and electrical measurements, but these methods do not provide information about the structural integrity of connectors. In this work, structural health monitoring (SHM) of compression connectors was studied using electromechanical impedance (EMI) analysis. Lead zirconate titanate (PZT)-5A was identified as a smart material for SHM. A flexible high-temperature bonding layer was used to address challenges in PZT integration due to a significant difference in the coefficients of thermal expansion of PZT and the aluminum substrate. The steel joint on the steel core was investigated because it is responsible for the ultimate tensile strength of the connector. Tensile testing was used to induce structural damage to the joint, or steel core pullout, and thermal cycling introduced additional structural perturbations. EMI measurements were conducted between the tests. The root mean square deviation (RMSD) of EMI was identified as a damage index. The use of steel joints has been shown to enable SHM under simulated conditions. The EMI signature is sensitive to variations in structural conditions. RMSD can be correlated to the structural health of a connector and has potential for use in the SHM and structural integrity evaluation.

  15. An Insight on Right of Way and its Cost for Power Transmission Cable and Conventional Overhead Transmission Lines

    NASA Astrophysics Data System (ADS)

    Khandelwal, P.; Pachori, A.; Khandelwal, T.

    2013-12-01

    This paper provides the complete information related to Right of Way (RoW) for the construction of new power transmission line (TL) in terms of present cost for overhead transmission line and underground XLPE transmission cable. The former part of the paper describes the general procedure and rules for acquisition of land for RoW by transmission asset owner (TAO) while in the later part the cost associated to acquire RoW and its impact on the cost of adjacent land have been detailed. It also discusses the actual dismantling cost including the cost of waste metal what TAO get after completion of lifecycle of TL due to increase in metal prices. In this paper cost of RoW after completion of lifecycle of TL is also highlighted. This paper compares the cost of RoW for overhead transmission line and underground XLPE transmission cable for construction of new TL. Also for old transmission infrastructure cost of RoW for change from overhead transmission line to underground XLPE transmission cable is detailed by application of replacement model.

  16. Axon initial segment Kv1 channels control axonal action potential waveform and synaptic efficacy.

    PubMed

    Kole, Maarten H P; Letzkus, Johannes J; Stuart, Greg J

    2007-08-16

    Action potentials are binary signals that transmit information via their rate and temporal pattern. In this context, the axon is thought of as a transmission line, devoid of a role in neuronal computation. Here, we show a highly localized role of axonal Kv1 potassium channels in shaping the action potential waveform in the axon initial segment (AIS) of layer 5 pyramidal neurons independent of the soma. Cell-attached recordings revealed a 10-fold increase in Kv1 channel density over the first 50 microm of the AIS. Inactivation of AIS and proximal axonal Kv1 channels, as occurs during slow subthreshold somatodendritic depolarizations, led to a distance-dependent broadening of axonal action potentials, as well as an increase in synaptic strength at proximal axonal terminals. Thus, Kv1 channels are strategically positioned to integrate slow subthreshold signals, providing control of the presynaptic action potential waveform and synaptic coupling in local cortical circuits.

  17. Transmission line resonance technique for eccentric core optical fibers

    NASA Astrophysics Data System (ADS)

    Georgantzos, E.; Boucouvalas, A. C.

    2016-12-01

    In several cases optical fibers in telecommunications have cores of non circular geometry. Fibre optic deformations appear in optical fibres for many reasons. Optical fibre core ellipticity for example where the fibre optic core is not perfectly circular due to fibre optic manufacturing tolerances, is measured and often is a problem. Optical fibre core eccentricity, where the fibre core is not on the axis of the fibre, but it is offset by a small length. This is another issue and very important for ensuring performance low loss splices and connector losses. Both of ellipticity and eccentricity are specified in accordance to international standards for fibre optic manufacturing telecommunications grade fibres. The present paper studies ellipticity and core eccentricity specifically and presents a new method for analysing their effect. We present an extension of the transmission line technique as a means of studying such fibers and deriving necessary parameters. Conformal mapping on the other hand is a simple mathematical tool by which we can generate sets of orthogonal two-dimensional coordinate systems. Shortly a conformal map of Cartesian two-dimensional space is defined by any analytical function W(z) where z, w, are: z = x + jy, W = θ + j φ The function deriving by the conformal mapping transformation h(θ ,φ )=| ∂w/∂z | = 1/|∂z/∂w|, can be used in order to define ∇A → and ∇×A → where A → is the magnetic or electric field in the derived orthogonal coordinate system. Useful conformal maps for fiber optics applications should have the property that the equation θ(x, y) = constant, is forming closed curves in a Cartesian two-dimensional space (x,y). If θ(x, y) = constant represents a set of co-eccentric circles, we obtain the normal case of conventional fibers with circular cores. If θ(x, y) = constant represents a set of eclipses, we are have the formation of elliptic core optical fibers. If θ(x, y) = constant represents a set of

  18. INSTRUMENTATION FOR SURVEYING ACOUSTIC SIGNALS IN NATURAL GAS TRANSMISSION LINES

    SciTech Connect

    John L. Loth; Gary J. Morris; George M. Palmer; Richard Guiler; Deepak Mehra

    2003-09-01

    In the U.S. natural gas is distributed through more than one million miles of high-pressure transmission pipelines. If all leaks and infringements could be detected quickly, it would enhance safety and U.S. energy security. Only low frequency acoustic waves appear to be detectable over distances up to 60 km where pipeline shut-off valves provide access to the inside of the pipeline. This paper describes a Portable Acoustic Monitoring Package (PAMP) developed to record and identify acoustic signals characteristic of: leaks, pump noise, valve and flow metering noise, third party infringement, manual pipeline water and gas blow-off, etc. This PAMP consists of a stainless steel 1/2 inch NPT plumbing tree rated for use on 1000 psi pipelines. Its instrumentation is designed to measure acoustic waves over the entire frequency range from zero to 16,000 Hz by means of four instruments: (1) microphone, (2) 3-inch water full range differential pressure transducer with 0.1% of range sensitivity, (3) a novel 3 inch to 100 inch water range amplifier, using an accumulator with needle valve and (4) a line-pressure transducer. The weight of the PAMP complete with all accessories is 36 pounds. This includes a remote control battery/switch box assembly on a 25-foot extension chord, a laptop data acquisition computer on a field table and a sun shield.

  19. Hybrid Transmission Line for ECRH in the Helically Symmetric Experiment

    NASA Astrophysics Data System (ADS)

    Radder, J. W.; Likin, K. M.; Anderson, F. S. B.; Anderson, D. T.

    2008-04-01

    The HSX oversized, mode-converting ECRH transmission line has been upgraded to a hybrid system to increase launched microwave power and reduce electrical arcing. Filtering of high-order, spurious modes ensures efficient coupling to a Gaussian beam for optimal electron heating. A Vlasov mode converter and two phase-correcting ellipsoidal mirrors convert the TE02 gyrotron output mode to a symmetric, linearly polarized, microwave beam. A swappable twist reflector plate rotates beam polarization for 2nd-harmonic X-mode or fundamental O-mode ECRH. Long distances are traversed by coupling the beam to a dual-mode (TE11 + TM11), smooth, circular cross-section waveguide. This system has been successfully tested without arcing for 50 ms pulses and over 100 kW of launched power. Analysis of the microwave beam for 50 kW, 2 ms microwave pulses reveals agreement with predicted beam shapes at two beam locations. The new system has also demonstrated increased plasma stored energy for ECRH plasmas with equal launched power.

  20. Transmission lines with very lossy conductors and seawater return

    NASA Astrophysics Data System (ADS)

    Martin, G. E.

    1982-10-01

    There are potential benefits in undersea cable technology by the use of copper-coated non-conductors (Kevlar) or poor conductors (graphite) with conventional or sea-water outer conductor. Kevlar is a very strong non-conductive fiber even in small sizes and it can be fabricated as a bundle of many copper-coated strands. Non-metallic conductors are being developed for a wide range of uses. For example, graphite materials are being used to provide strong flexible golf clubs and spark plug wires that cause minimal interference with radio reception. There is extensive research and development in these materials such as development of light-weight strong materials for airplanes. The particular application of interest in the research reported here is the cables used as undersea data links for transmitting signals from hydrophones under water to sonobuoy radio transmitters at the surface of the ocean. Non-metallic conducting materials have recently shown impressive capabilities and prospective future gains from the viewpoint of such ocean applications including high strength, low specific gravity and relatively low resistance. This report is intended to provide the technical development of such data transmission lines in order to provide the basis for design of such cables. The technical basis for the design of undersea cables is provided in considerable detail. The electromagnetic theory, algorithm development, and properties of materials are described. Optimal designs are considered.

  1. Requirements for self-magnetically insulated transmission lines

    SciTech Connect

    VanDevender, J. Pace; Pointon, Timothy D.; Seidel, David B.; Struve, Kenneth W.; Jennings, Christopher; Oliver, Bryan V.; Schneider, Larry X.

    2015-03-01

    Self-magnetically insulated transmission lines (MITLs) connect pulsed-power drivers with a load. Although the technology was originally developed in the 1970s and is widely used today in super power generators, failure of the technology is the principal limitation on the power that can be delivered to an experiment. We address issues that are often overlooked, rejected after inadequate simulations, or covered by overly conservative assumptions: (i) electron retrapping in coupling MITLs to loads, (ii) the applicability of collisionless versus collisional electron flow, (iii) power transport efficiency as a function of the geometry at the beginning of the MITL, (iv) gap closure and when gap closure can be neglected, and (v) the role of negative ions in causing anode plasmas and enhancing current losses. We suggest a practical set of conservative design requirements for self-magnetically insulated electron flow based on the results discussed in this paper and on previously published results. The requirements are not necessarily severe constraints in all MITL applications; however, each of the 18 suggested requirements should be examined in the design of a MITL and in the investigation of excessive losses.

  2. Electron flow stability in magnetically insulated vacuum transmission lines

    NASA Astrophysics Data System (ADS)

    Rose, D. V.; Genoni, T. C.; Clark, R. E.; Welch, D. R.; Stygar, W. A.

    2011-03-01

    We evaluate the stability of electron current flow in high-power magnetically insulated transmission lines (MITLs). A detailed model of electron flow in cross-field gaps yields a dispersion relation for electromagnetic (EM) transverse magnetic waves [R. C. Davidson et al., Phys. Fluids 27, 2332 (1984)] which is solved numerically to obtain growth rates for unstable modes in various sheath profiles. These results are compared with two-dimensional (2D) EM particle-in-cell (PIC) simulations of electron flow in high-power MITLs. We find that the macroscopic properties (charge and current densities and self-fields) of the equilibrium profiles observed in the simulations are well represented by the laminar-flow model of Davidson et al. Idealized simulations of sheared flow in electron sheaths yield growth rates for both long (diocotron) and short (magnetron) wavelength instabilities that are in good agreement with the dispersion analysis. We conclude that electron sheaths that evolve self-consistently from space-charged-limited emission of electrons from the cathode in well-resolved 2D EM PIC simulations form stable profiles.

  3. Electron Flow Stability in Magnetically Insulated Vacuum Transmission Lines

    NASA Astrophysics Data System (ADS)

    Rose, D. V.; Genoni, T. C.; Clark, R. E.; Welch, D. R.; Stygar, W. A.

    2010-11-01

    We evaluate the stability of electron current flow in high power magnetically insulated transmission lines (MITLs). A detailed model of electron flow in cross-field gaps yields a dispersion relation for electromagnetic TM waves [1] which is solved numerically to obtain growth rates for unstable modes in various density profiles. These results are compared with 2D particle-in-cell (PIC) simulations of electron flow in high power MITLs. We find that the macroscopic properties (charge and current density, self-fields) of the equilibrium profiles observed in the simulations are well represented by the laminar flow model of [1]. Idealized simulations of sheared flow in electron sheaths show that unstable, sharp-cutoff radial density profiles rapidly evolve into stable flows with a more gradual density gradient. Growth rates for both long (diocotron) and short (magnetron) wavelength instabilities observed in the simulations agree well with the dispersion analysis. We conclude that electron sheaths in high power 2D MITL flows form stable profiles and that sheath expansion is not caused by flow instability. Subsequently, we investigate the impact of electrode plasma formation and evolution on sheath stability and gap closure using PIC simulations. We compare MITL simulations with experimental measurements. [1] R. C. Davidson, et al., Phys. Fluids 27, 2332 (1984).

  4. Electron flow stability in magnetically insulated vacuum transmission lines

    SciTech Connect

    Rose, D. V.; Genoni, T. C.; Clark, R. E.; Welch, D. R.; Stygar, W. A.

    2011-03-15

    We evaluate the stability of electron current flow in high-power magnetically insulated transmission lines (MITLs). A detailed model of electron flow in cross-field gaps yields a dispersion relation for electromagnetic (EM) transverse magnetic waves [R. C. Davidson et al., Phys. Fluids 27, 2332 (1984)] which is solved numerically to obtain growth rates for unstable modes in various sheath profiles. These results are compared with two-dimensional (2D) EM particle-in-cell (PIC) simulations of electron flow in high-power MITLs. We find that the macroscopic properties (charge and current densities and self-fields) of the equilibrium profiles observed in the simulations are well represented by the laminar-flow model of Davidson et al. Idealized simulations of sheared flow in electron sheaths yield growth rates for both long (diocotron) and short (magnetron) wavelength instabilities that are in good agreement with the dispersion analysis. We conclude that electron sheaths that evolve self-consistently from space-charged-limited emission of electrons from the cathode in well-resolved 2D EM PIC simulations form stable profiles.

  5. Precision electron flow measurements in a disk transmission line.

    SciTech Connect

    Clark, Waylon T.; Pelock, Michael D.; Martin, Jeremy Paul; Jackson, Daniel Peter Jr.; Savage, Mark Edward; Stoltzfus, Brian Scott; Mendel, Clifford Will, Jr.; Pointon, Timothy David

    2008-01-01

    An analytic model for electron flow in a system driving a fixed inductive load is described and evaluated with particle in cell simulations. The simple model allows determining the impedance profile for a magnetically insulated transmission line given the minimum gap desired, and the lumped inductance inside the transition to the minimum gap. The model allows specifying the relative electron flow along the power flow direction, including cases where the fractional electron flow decreases in the power flow direction. The electrons are able to return to the cathode because they gain energy from the temporally rising magnetic field. The simulations were done with small cell size to reduce numerical heating. An experiment to compare electron flow to the simulations was done. The measured electron flow is {approx}33% of the value from the simulations. The discrepancy is assumed to be due to a reversed electric field at the cathode because of the inductive load and falling electron drift velocity in the power flow direction. The simulations constrain the cathode electric field to zero, which gives the highest possible electron flow.

  6. Electron flow stability in magnetically insulated vacuum transmission lines.

    SciTech Connect

    Genoni, Thomas C.; Stygar, William A.; Welch, Dale Robert; Clark, R. E.; Rose, David V.

    2010-11-01

    We evaluate the stability of electron current flow in high-power magnetically insulated transmission lines (MITLs). A detailed model of electron flow in cross-field gaps yields a dispersion relation for electromagnetic (EM) transverse magnetic waves [R. C. Davidson et al., Phys. Fluids 27, 2332 (1984)] which is solved numerically to obtain growth rates for unstable modes in various sheath profiles. These results are compared with two-dimensional (2D) EM particle-in-cell (PIC) simulations of electron flow in high-power MITLs. We find that the macroscopic properties (charge and current densities and self-fields) of the equilibrium profiles observed in the simulations are well represented by the laminar-flow model of Davidson et al. Idealized simulations of sheared flow in electron sheaths yield growth rates for both long (diocotron) and short (magnetron) wavelength instabilities that are in good agreement with the dispersion analysis. We conclude that electron sheaths that evolve self-consistently from space-charged-limited emission of electrons from the cathode in well-resolved 2D EM PIC simulations form stable profiles.

  7. Estuarine Habitat Assessment for Construction of a Submarine Transmission Line

    NASA Astrophysics Data System (ADS)

    Hamouda, Amr Z.; Abdel-Salam, Khaled M.

    2010-07-01

    The present paper describes a submarine survey using the acoustic discrimination system QTC VIEW (Series V) as an exploratory tool to adjust final route alignment of a new pipeline. By using acoustic sound survey as an exploratory tool described in this paper to adjust final route alignment of a new pipeline to minimize the environmental impact caused and ultimately to avoid any mitigation measures. The transmission pipeline extended from the shore line of Abu-Qir Bay, on the Mediterranean Sea in Egypt, out to 70 nautical miles at sea (60 m water depth). Four main surface sediment types were defined in the study area, namely fine sand, silty sand, silt and clay. Results of the acoustic classification revealed four acoustic classes. The first acoustic class corresponded to fine sand, absence of shell debris and very poor habitats characteristics. The second acoustic class is predominant in the study area and corresponds to the region occupied by silt. It is also characterized by intermediate diversity of macrobenthic invertebrate community which is mainly characterized by polychaeta. The third acoustic class is characterized by silt to silty clay. It is characterized by a high diversity of macrobenthic invertebrate community which is mainly polychaeta with an intermediate diversity of gastropoda and bivalvia. The final acoustic class is characterized by clay and high occurrence of shell debris of gastropoda, bivalvia and polychaeta.

  8. Radial transmission line analysis of multi-layer structures

    SciTech Connect

    Hahn, H.; Hammons, L.

    2011-03-28

    The analysis of multi-layer beam tubes is a standard problem and involves axially propagating waves. This treatment is ill suited to a short multi-layer structure such as the present example of a ferrite covered ceramic break in the beam tube at the ERL photo-cathode electron gun. This paper demonstrates that such structure can better be treated by radial wave propagation. The theoretical method is presented and numerical results are compared with measured network analyser data and Microwave Studio generated simulations. The results confirm the concept of radial transmission lines as a valid analytical method. An Energy Recovery Linac (ERL) is being constructed at this laboratory for the purpose of research towards an envisioned Electron Ion Collider. One of the pertinent topics is damping of Higher Order Modes (HOM). In this ERL, the damping is provided by ferrite absorbers in the beam tube. A modified version thereof, a ceramic break surrounded by ferrite, is planed for the superconducting electron gun. The damper here is located at room temperature just outside of the gun. If used in a cavity chain, the ceramic break is in the vacuum tube at helium temperature whereas the ferrite is moved into the cryostat insulating vacuum allowing higher temperatures. The general properties of the ferrite HOM dampers have been published but are more detailed in this paper.

  9. Requirements for self-magnetically insulated transmission lines

    DOE PAGES

    VanDevender, J. Pace; Pointon, Timothy D.; Seidel, David B.; ...

    2015-03-01

    Self-magnetically insulated transmission lines (MITLs) connect pulsed-power drivers with a load. Although the technology was originally developed in the 1970s and is widely used today in super power generators, failure of the technology is the principal limitation on the power that can be delivered to an experiment. We address issues that are often overlooked, rejected after inadequate simulations, or covered by overly conservative assumptions: (i) electron retrapping in coupling MITLs to loads, (ii) the applicability of collisionless versus collisional electron flow, (iii) power transport efficiency as a function of the geometry at the beginning of the MITL, (iv) gap closuremore » and when gap closure can be neglected, and (v) the role of negative ions in causing anode plasmas and enhancing current losses. We suggest a practical set of conservative design requirements for self-magnetically insulated electron flow based on the results discussed in this paper and on previously published results. The requirements are not necessarily severe constraints in all MITL applications; however, each of the 18 suggested requirements should be examined in the design of a MITL and in the investigation of excessive losses.« less

  10. Application of A Line Ampacity Model and Its Use in Transmission Lines Operations

    NASA Astrophysics Data System (ADS)

    Šnajdr, Jaroslav; Sedláček, Jan; Vostracký, Zdenek

    2014-08-01

    A conductor thermal model related to CIGRE and IEEE solutions was developed and compared with measurements. Two pylons of a single line were equipped with weather monitoring stations and conductor temperature sensors based on Surface Acoustic Wave (SAW) principle. Also a fiber optic distributed temperature sensing system was installed to provide additional data. Over 2.5 million data points were evaluated. Developed model deviation for more than 99 % of values proved to be ±1 °C for SAW sensor and ±3.5 °C for the fiber optic measurement. Several ampacity determination methods were described from a transmission grid operator's point of view. Their features were compared in order to show at which planning period they could be useful. A new method for dynamic line rating determination was proposed. Although it reduces maximum ampacity gain, its advantage lies in minimizing measurement systems while retaining relatively stable value and low risk of temperature limit exceeding.

  11. Dependence of NMR noise line shapes on tuning, matching, and transmission line properties

    PubMed Central

    Bendet-Taicher, Eli; Müller, Norbert; Jerschow, Alexej

    2014-01-01

    The tuning and matching conditions of rf circuits, as well as the properties of the transmission lines connecting these to the preamplifier, have direct consequences for NMR probe sensitivity and as for the optimum delivery of rf power to the sample. In addition, tuning/matching conditions influence radiation damping effects, which manifest themselves as fast signal flip-back and line broadening effects, and can lead to concentration-dependent frequency shifts. Previous studies have also shown that the appearance of spin-noise and absorbed circuit noise signals heavily depended on tuning settings. Consequently, all these phenomena are linked together. The mutual connections and interdependences of these effects are highlighted and reviewed here. PMID:25505374

  12. Problems of operating the 500-kV outdoor electrical equipment of the Sayano-Shushenskoe hydroelectric station

    SciTech Connect

    Mitrofanov, A.N.

    1994-10-01

    The Sayano-Shushenskoe hydroelectric station is part of the Siberian interconnected power system. Power is transmitted to the grid by two 500 kV transmission lines. The site characteristics made nearby placement of conventional 500 kV switchyard equipment impossible. The original plans were to place the switchyard 35 km away, but the 500 kV lines to the yard would have passed through mountain regions with intense thunderstorm activity. Because of the unique design of the generators, the number of lightning-induced disconnects was substantial. For greater reliability, 500 kV equipment suitable for placement at the sight was designed, and the overall electrical layout of the yard was revised by reconstructing the middle network of the 4/3 scheme to three networks with two switches per connection. Sectioning of the collecting bus systems was necessary for a further increase in the reliability of the yard.

  13. Economic analysis of transmission line engineering based on industrial engineering

    NASA Astrophysics Data System (ADS)

    Li, Yixuan

    2017-05-01

    The modern industrial engineering is applied to the technical analysis and cost analysis of power transmission and transformation engineering. It can effectively reduce the cost of investment. First, the power transmission project is economically analyzed. Based on the feasibility study of power transmission and transformation project investment, the proposal on the company system cost management is put forward through the economic analysis of the effect of the system. The cost management system is optimized. Then, through the cost analysis of power transmission and transformation project, the new situation caused by the cost of construction is found. It is of guiding significance to further improve the cost management of power transmission and transformation project. Finally, according to the present situation of current power transmission project cost management, concrete measures to reduce the cost of power transmission project are given from the two aspects of system optimization and technology optimization.

  14. 78 FR 44586 - Draft Environmental Assessment and Proposed Cross Valley Transmission Line Habitat Conservation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-24

    ... Habitat Conservation Plan, Tulare County, California AGENCY: Fish and Wildlife Service, Interior. ACTION: Notice of availability; receipt of permit application, draft environmental assessment, proposed habitat... prepared the draft Cross Valley Transmission Line Habitat Conservation Plan (Cross Valley Line HCP) (HCP...

  15. View of transmission line tower on LABPL2 northwest of Boulder ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View of transmission line tower on LABPL2 northwest of Boulder City Substation, view northwest - Hoover Dam, Los Angeles Bureau of Power & Light Lines 1-3, U.S. Highway 93, Boulder City, Clark County, NV

  16. ``Multifractals in Transmission of Off-line & On-line E-Voting Systems''

    NASA Astrophysics Data System (ADS)

    Maksoed, Wh-

    An e-voting systems is a voting system in which the election data is recorded, stored & processed primarily as digital information. Those are 2 type of e-voting systems: off-line & on-line systems[Alaguvel & Gnanavel, 2013]. ``Using transfer matrix method & multifractal theory, we studied the transmission properties of 1D generalized Fibonacci structures GF(m.n) in which m & n different intervals are integer according to a substitution rule[Yuannong Zhang, et.al,:Multifractal properties of 1D quasi-period Photonic Crystal''. ``Transmission spectra of 1D fractal multilayer structures are found to exhibit self-similar properties'' says Zhukovsky & Lavrinenko in ``Spectral self-similarity in fractal 1D photonic structures'',Photonics & Nanostructures, 2005 whereas Jacob Trevino, et.al studies `structural properties, photonic density of state & bandedge modes of Vogel spiral arrays of dielectric cylinders in air'. Acknowledgment to HE. Mr. AUGUST PARENGKUAN if accepts 1995-2005 Invoicing & Fulfillments to ``KOMPAS'' cq the Prodi of Physics ITB.

  17. Electric Utility Transmission and Distribution Line Engineering Program

    SciTech Connect

    Peter McKenny

    2010-08-31

    Economic development in the United States depends on a reliable and affordable power supply. The nation will need well educated engineers to design a modern, safe, secure, and reliable power grid for our future needs. An anticipated shortage of qualified engineers has caused considerable concern in many professional circles, and various steps are being taken nationwide to alleviate the potential shortage and ensure the North American power system's reliability, and our world-wide economic competitiveness. To help provide a well-educated and trained workforce which can sustain and modernize the nation's power grid, Gonzaga University's School of Engineering and Applied Science has established a five-course (15-credit hour) Certificate Program in Transmission and Distribution (T&D) Engineering. The program has been specifically designed to provide working utility engineering professionals with on-line access to advanced engineering courses which cover modern design practice with an industry-focused theoretical foundation. A total of twelve courses have been developed to-date and students may select any five in their area of interest for the T&D Certificate. As each course is developed and taught by a team of experienced engineers (from public and private utilities, consultants, and industry suppliers), students are provided a unique opportunity to interact directly with different industry experts over the eight weeks of each course. Course material incorporates advanced aspects of civil, electrical, and mechanical engineering disciplines that apply to power system design and are appropriate for graduate engineers. As such, target students for the certificate program include: (1) recent graduates with a Bachelor of Science Degree in an engineering field (civil, mechanical, electrical, etc.); (2) senior engineers moving from other fields to the utility industry (i.e. paper industry to utility engineering or project management positions); and (3) regular working

  18. Extragalactic circuits, transmission lines, and CR particle acceleration

    NASA Astrophysics Data System (ADS)

    Kronberg, Philipp P.; Lovelace, Richard V. E.

    2015-08-01

    A non-negligible fraction of a Supermassive Black Hole's (SMBH) rest mass energy gets transported into extragalactic space by a remarkable process in jets which are incompletely understood. What are the physical processes which transport this energy? It is likely that the energy flows electromagnetically, rather than via a particle beam flux. The deduced electromagnetic fields may produce particles of energy as high as ˜ 1020 eV. The energetics of SMBH accretion disk models and the electromagnetic energy transfer imply that a SMBH should generate a 1018 - 1019 Ampères current close to the black hole and its accretion disk. We describe the so far best observation-based estimate of the magnitude of the current flow along the axis of the jet extending from the nucleus of the active galaxy in 3C303. The current is measured to be I ˜ 1018 Ampères at ˜ 40 kpc away from the AGN. This indicates that organised current flow remains intact over multi-kpc distances. The electric current I transports electromagnetic power into free space, P = I2Z, where Z ˜ 30 Ohms is related to the impedance of free space, and this points to the existence of cosmic electric circuit. The associated electric potential drop, V = IZ, is of the order of that required to generate Ultra High Energy Cosmic Rays (UHECR). We also explore further implications, including disruption/deflection of the power flow and also why such measurements, exemplified by those on 3C303, are currently very difficult to make and to unambiguously interpret. This naturally leads to the topic of how such measurements can be extended and improved in the future. We describe the analogy of electromagnetically dominated jets with transmission lines. High powered jets in vacuo can be understood by approximate analogy with a waveguide. The importance of inductance, impedance, and other laboratory electrical concepts are discussed in this context.

  19. Transmission line analogy for relativistic Poynting-flux jets

    NASA Astrophysics Data System (ADS)

    Lovelace, R. V. E.; Kronberg, P. P.

    2013-04-01

    Radio emission, polarization and Faraday rotation maps of the radio jet of the galaxy 3C 303 have shown that one knot of this jet carries a galactic-scale electric current and that it is magnetically dominated. We develop the theory of magnetically dominated or Poynting-flux jets by making an analogy of a Poynting jet with a transmission line or waveguide carrying a net current and having a potential drop across it (from the jet's axis to its radius) and a definite impedance which we derive. The electromagnetic energy flow in the jet is the jet impedance times the square of the jet current. The observed current in 3C 303 can be used to calculate the electromagnetic energy flow in this magnetically dominated jet. Time dependent but not necessarily small perturbations of a Poynting-flux jet are described by the `telegrapher's equations'. These predict the propagation speed of disturbances and the effective wave impedance for forward and backward propagating wave components. A localized disturbance of a Poynting jet gives rise to localized dissipation in the jet which may explain the enhanced synchrotron radiation in the knots of the 3C 303 jet, and also in the apparently stationary knot HST-1 in the jet near the nucleus of the nearby galaxy M87. For a relativistic Poynting jet on parsec scales, the reflected voltage wave from an inductive termination or load can lead to a backward propagating wave which breaks down the magnetic insulation of the jet giving |{boldsymbol E}| /|{boldsymbol B}|ge 1. At the threshold for breakdown, |{boldsymbol E}|/|{boldsymbol B}|=1, positive and negative particles are directly accelerated in the {boldsymbol E} × {boldsymbol B} direction which is approximately along the jet axis. Acceleration can occur up to Lorentz factors ˜107. This particle acceleration mechanism is distinct from that in shock waves and that in magnetic field reconnection.

  20. 76 FR 34969 - Extension of Scoping Period for the Northern Pass Transmission Line Project Environmental Impact...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-15

    ... Extension of Scoping Period for the Northern Pass Transmission Line Project Environmental Impact Statement... (DOE) is reopening the public scoping period for the Northern Pass Transmission Line Project... being provided by Northern Pass, DOE is reopening the scoping period. DOE will determine the close...

  1. 78 FR 57372 - Northern Pass Transmission Line Project Environmental Impact Statement: Announcement of Change in...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-18

    ... Northern Pass Transmission Line Project Environmental Impact Statement: Announcement of Change in Public... amended Notice of Intent (NOI) to modify the scope of the Northern Pass Transmission Line Project... previously announced this change in public meeting location on both the Northern Pass EIS Web site at...

  2. Maximum power transfer in A.C. transmission lines limited by voltage stability

    SciTech Connect

    Raviprakasha, M.S.; Ramar, K.

    1995-12-31

    Closed form expressions for maximum power transfer limited by voltage stability and the corresponding voltage in AC transmission lines for constant power and constant impedance type loads are derived. The transmission line is represented by its n-equivalent model. It is shown that the maximum power transfer point is independent of the type of load.

  3. View facing east (70°) of Transmission Line crossing Marias River, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View facing east (70°) of Transmission Line crossing Marias River, near Structure 47-9, grain elevators in town of Loma visible in background - Havre Rainbow Transmission Line, Havre City to Great Falls vicinity, Montana, Great Falls, Cascade County, MT

  4. Some Little-Known Facts about Transmission Lines and Some New Results

    ERIC Educational Resources Information Center

    Dutta Roy, Suhash C.

    2010-01-01

    The study of transmission lines forms an integral part of any curriculum in electrical engineering. This paper presents some little-known but interesting facts about transmission lines, which are generally not found in textbooks, along with some new facts, which arose as extensions of these little-known ones. The facts highlighted in this paper…

  5. 49 CFR 192.711 - Transmission lines: General requirements for repair procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Transmission lines: General requirements for repair procedures. 192.711 Section 192.711 Transportation Other Regulations Relating to Transportation... Maintenance § 192.711 Transmission lines: General requirements for repair procedures. (a) Temporary repairs...

  6. 49 CFR 192.711 - Transmission lines: General requirements for repair procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Transmission lines: General requirements for repair procedures. 192.711 Section 192.711 Transportation Other Regulations Relating to Transportation... Maintenance § 192.711 Transmission lines: General requirements for repair procedures. (a) Temporary repairs...

  7. Improvements to a transmission-line model of a main-ring cavity

    SciTech Connect

    Swain, G.R.

    1989-01-01

    A transmission-line model has been used in the design of a ferrite-tuned prototype rf cavity for a hadron-facility main ring. The computer codes SUPERFISH and MAFIA were used to refine and validate the transmission line model representations for the accelerating gap, the coaxial tee, and the ferrite tuner assembly. 5 refs., 9 figs., 4 tabs.

  8. A calibration technique for measuring the complex permittivity of materials with planar transmission lines

    USDA-ARS?s Scientific Manuscript database

    A simple two-standard calibration procedure for determining the permittivity of a material from the propagation constant measured with planar transmission lines is presented. The suitability of this procedure is demonstrated by using a coplanar waveguide transmission-line sensor to measure the permi...

  9. 49 CFR 192.713 - Transmission lines: Permanent field repair of imperfections and damages.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Transmission lines: Permanent field repair of imperfections and damages. 192.713 Section 192.713 Transportation Other Regulations Relating to Transportation... Maintenance § 192.713 Transmission lines: Permanent field repair of imperfections and damages. (a)...

  10. 49 CFR 192.715 - Transmission lines: Permanent field repair of welds.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Transmission lines: Permanent field repair of welds. 192.715 Section 192.715 Transportation Other Regulations Relating to Transportation (Continued... § 192.715 Transmission lines: Permanent field repair of welds. Each weld that is unacceptable...

  11. 49 CFR 192.713 - Transmission lines: Permanent field repair of imperfections and damages.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Permanent field repair of imperfections and damages. 192.713 Section 192.713 Transportation Other Regulations Relating to Transportation... Maintenance § 192.713 Transmission lines: Permanent field repair of imperfections and damages. (a)...

  12. 49 CFR 192.715 - Transmission lines: Permanent field repair of welds.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Transmission lines: Permanent field repair of welds. 192.715 Section 192.715 Transportation Other Regulations Relating to Transportation (Continued... § 192.715 Transmission lines: Permanent field repair of welds. Each weld that is unacceptable...

  13. 49 CFR 192.715 - Transmission lines: Permanent field repair of welds.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Transmission lines: Permanent field repair of welds. 192.715 Section 192.715 Transportation Other Regulations Relating to Transportation (Continued... § 192.715 Transmission lines: Permanent field repair of welds. Each weld that is unacceptable...

  14. 49 CFR 192.715 - Transmission lines: Permanent field repair of welds.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Permanent field repair of welds. 192.715 Section 192.715 Transportation Other Regulations Relating to Transportation (Continued... § 192.715 Transmission lines: Permanent field repair of welds. Each weld that is unacceptable...

  15. 49 CFR 192.715 - Transmission lines: Permanent field repair of welds.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Transmission lines: Permanent field repair of welds. 192.715 Section 192.715 Transportation Other Regulations Relating to Transportation (Continued... § 192.715 Transmission lines: Permanent field repair of welds. Each weld that is unacceptable...

  16. 78 FR 76140 - Extension of Public Comment Period for the Champlain Hudson Power Express Transmission Line...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-16

    ... Extension of Public Comment Period for the Champlain Hudson Power Express Transmission Line Project Draft... Hudson Power Express Transmission Line Project Draft Environmental Impact Statement (DOE/EIS-0447). The... permit to the Applicant, Champlain Hudson Power Express, Inc. (CHPEI), to construct, operate,...

  17. Some Little-Known Facts about Transmission Lines and Some New Results

    ERIC Educational Resources Information Center

    Dutta Roy, Suhash C.

    2010-01-01

    The study of transmission lines forms an integral part of any curriculum in electrical engineering. This paper presents some little-known but interesting facts about transmission lines, which are generally not found in textbooks, along with some new facts, which arose as extensions of these little-known ones. The facts highlighted in this paper…

  18. Evaluation of the probability of arrester failure in a high-voltage transmission line using a Q learning artificial neural network model

    NASA Astrophysics Data System (ADS)

    Ekonomou, L.; Karampelas, P.; Vita, V.; Chatzarakis, G. E.

    2011-04-01

    One of the most popular methods of protecting high voltage transmission lines against lightning strikes and internal overvoltages is the use of arresters. The installation of arresters in high voltage transmission lines can prevent or even reduce the lines' failure rate. Several studies based on simulation tools have been presented in order to estimate the critical currents that exceed the arresters' rated energy stress and to specify the arresters' installation interval. In this work artificial intelligence, and more specifically a Q-learning artificial neural network (ANN) model, is addressed for evaluating the arresters' failure probability. The aims of the paper are to describe in detail the developed Q-learning ANN model and to compare the results obtained by its application in operating 150 kV Greek transmission lines with those produced using a simulation tool. The satisfactory and accurate results of the proposed ANN model can make it a valuable tool for designers of electrical power systems seeking more effective lightning protection, reducing operational costs and better continuity of service.

  19. A study of electric transmission lines for use on the lunar surface

    NASA Technical Reports Server (NTRS)

    Gaustad, Krista L.; Gordon, Lloyd B.; Weber, Jennifer R.

    1994-01-01

    The sources for electrical power on a lunar base are said to include solar/chemical, nuclear (static conversion), and nuclear (dynamic conversion). The transmission of power via transmission lines is more practical than power beaming or superconducting because of its low cost and reliable, proven technology. Transmission lines must have minimum mass, maximum efficiency, and the ability to operate reliably in the lunar environment. The transmission line design includes conductor material, insulator material, conductor geometry, conductor configuration, line location, waveform, phase selection, and frequency. This presentation oulines the design. Liquid and gaseous dielectrics are undesirable for long term use in the lunar vacuum due to a high probability of loss. Thus, insulation for high voltage transmission line will most likely be solid dielectric or vacuum insulation.

  20. Millimeter-Gap Magnetically Insulated Transmission Line Power Flow Experiments

    SciTech Connect

    Hutsel, Brian Thomas; Stoltzfus, Brian S.; Fowler, William E.; LeChien, Keith R.; Mazarakis, Michael G.; Moore, James K.; Mulville, Thomas D.; Savage, Mark E.; Stygar, William A.; McKenney, John L.; Jones, Peter A.; MacRunnels, Diego J.; Long, Finis W.; Porter, John L.

    2014-09-01

    An experiment platform has been designed to study vacuum power flow in magnetically insulated transmission lines (MITLs). The platform was driven by the 400-GW Mykonos-V accelerator. The experiments conducted quantify the current loss in a millimeter-gap MITL with respect to vacuum conditions in the MITL for two different gap distances, 1.0 and 1.3 mm. The current loss for each gap was measured for three different vacuum pump down times. As a ride along experiment, multiple shots were conducted with each set of hardware to determine if there was a conditioning effect to increase current delivery on subsequent shots. The experiment results revealed large differences in performance for the 1.0 and 1.3 mm gaps. The 1.0 mm gap resulted in current loss of 40%-60% of peak current. The 1.3 mm gap resulted in current losses of less than 5% of peak current. Classical MITL models that neglect plasma expansion predict that there should be zero current loss, after magnetic insulation is established, for both of these gaps. The experiments result s indicate that the vacuum pressure or pump down time did not have a significant effect on the measured current loss at vacuum pressures between 1e-4 and 1e-5 Torr. Additionally, there was not repeatable evidence of a conditioning effect that reduced current loss for subsequent full-energy shots on a given set of hardware. It should be noted that the experiments conducted likely did not have large loss contributions due to ion emission from the anode due to the relatively small current densi-ties (25-40 kA/cm) in the MITL that limited the anode temperature rise due to ohmic heating. The results and conclusions from these experiments may have limited applicability to MITLs of high current density (>400 kA/cm) used in the convolute and load region of the Z which experience temperature increases of >400° C and generate ion emission from anode surfaces.

  1. TWO-CONDUCTOR LOW-PASS TRANSMISSION LINE THEORY.

    DTIC Science & Technology

    be incorporated into a practical line design. This may be accomplished through the use of lauric acid to solidify the line. (Author)...periodically load the line. Ferrite-filled dielectrics were investi gated. Experimental evidence indicates that little additional benefit is derived from

  2. Transmission line model for the near-instantaneous transmission of the ionospheric electric field and currents to the equator

    NASA Astrophysics Data System (ADS)

    Kikuchi, Takashi

    2014-02-01

    The simultaneous onset of the preliminary impulse (PI) of the geomagnetic sudden commencement at high latitude and dayside dip equator is explained by means of the TM0 mode waves propagating at the speed of light in the Earth-ionosphere waveguide (EIW) [Kikuchi et al., 1978]. A couple of issues remain to be addressed in the EIW model: (1) How is the TM0 mode wave excited by the field-aligned currents (FACs) in the polar region? (2) How are the quasi-steady ionospheric currents achieved by the TM0 mode waves? (3) How simultaneous or delayed are the onset and peak of the equatorial PI with respect to the high-latitude PI? To address these issues, we examine the TEM (TM0) mode wave propagation in the finite-length transmission lines replacing the pair of FACs (magnetosphere-ionosphere (MI) transmission line) and the Earth-ionosphere waveguide (ionosphere-ground (IG) transmission line). The issue (1) is addressed by showing that a fraction of the TEM mode wave is transmitted from the MI to IG transmission lines through the polar ionosphere. To address the issues (2) and (3), we examine the properties of the finite-length IG transmission line with finite ionospheric conductivity. It is shown that the ionospheric currents start to grow instantaneously and continue to grow gradually with time constants of 1-10 s depending on the ionospheric conductivity. The MIG transmission line enables us to explain the instantaneous onset and delayed peak time of the equatorial PI and quick electric field response of the low-latitude ionosphere and inner magnetosphere.

  3. Development of 66kV XLPE submarine cable using optical fiber as a mechanical-damage-detection-sensor

    SciTech Connect

    Nishimoto, Toshio; Miyahara, Tsutomu; Takehana, Hajime; Tateno, Fuminori

    1995-10-01

    Submarine cables are exposed to great risk of serious mechanical damage by ship anchors or equipment used for fishing. Detection of such damage in a submarine cable is a very useful technology for improving the reliability of a submarine cable transmission line. A mechanical-damage-detection-sensor using optical fiber was developed. A prototype 66kV XLPE submarine cable incorporating the sensor was manufactured for trial, and the ability of a sensor was confirmed by compression test. Actual 66kV XLPE submarine cable incorporating the sensor was manufactured for trial, and the ability of a sensor was confirmed by compression test. Actual 66kV XLPE submarine cable with the sensor was manufactured and installed as an operating transmission line in Japan.

  4. Sensor, method and system of monitoring transmission lines

    DOEpatents

    Syracuse, Steven J.; Clark, Roy; Halverson, Peter G.; Tesche, Frederick M.; Barlow, Charles V.

    2012-10-02

    An apparatus, method, and system for measuring the magnetic field produced by phase conductors in multi-phase power lines. The magnetic field measurements are used to determine the current load on the conductors. The magnetic fields are sensed by coils placed sufficiently proximate the lines to measure the voltage induced in the coils by the field without touching the lines. The x and y components of the magnetic fields are used to calculate the conductor sag, and then the sag data, along with the field strength data, can be used to calculate the current load on the line and the phase of the current. The sag calculations of this invention are independent of line voltage and line current measurements. The system applies a computerized fitter routine to measured and sampled voltages on the coils to accurately determine the values of parameters associated with the overhead phase conductors.

  5. 75 FR 63141 - Apalachicola National Forest; Florida; City of Tallahassee 230kV Southwestern Transmission Line

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-14

    ... FURTHER INFORMATION CONTACT: Harold Shenk, U.S. Forest Service, 57 Taff Drive, Crawfordville, FL 32327... Federal Information Relay Service (FIRS) at 1-800-877-8339 between 8 a.m. and 8 p.m., Eastern Time, Monday through Friday. SUPPLEMENTARY INFORMATION: Purpose and Need for Action The North American Electric...

  6. 76 FR 19744 - Final Tropic to Hatch 138 kV Transmission Line Project Environmental Impact Statement and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-08

    ... published in December 2009. The two documents, together, make up the FEIS/PMPA for the Tropic to Hatch 138 k... follow-up letter to e-mails or faxes, must be in writing and mailed to the appropriate address, as set...

  7. Propagation of Degenerate Band-Edge Modes Using Dual Nonidentical Coupled Transmission Lines

    NASA Astrophysics Data System (ADS)

    Zuboraj, A. Muhammed; Sertel, B. Kubilay; Volakis, C. John L.

    2017-06-01

    Degenerate band-edge (DBE) modes are known for their exceptionally high field intensity at the nearly flat dispersion-diagram profile. Because of the latter property, resonances supported by these modes are associated with a very strong field at the band edge. DBE modes and similar resonances of this class have been typically realized by introducing anisotropic dielectric slabs in volumetric photonic crystals. By contrast, in this paper, we present an analytic model of DBE modes using a simple set of nonidentical coupled transmission lines. The unequal phase velocities of the supported waves supported by these transmission lines lead to mode degeneracy, that in turn provide quartic solutions of dispersion (ω -β ) relations. The DBE mode appears as one these quartic solutions. As such, the proposed model generalizes the concept of DBE modes using the construct of nonidentical coupled transmission lines. In this paper, we also propose a propagation medium using a dual pair of nonidentical transmission lines. The medium is referred to as a "butterfly" structure and is composed of four coupled transmission lines. These four coupled transmission lines generate the TM01-like degenerate band-edge mode. This is done by coupling the TE modes supported on each pair of the transmission lines. Mode purity at the resonance frequency and the intense field profile on the axis are properties that can be exploited for high-power microwave sources.

  8. The Effect Analysis of Strain Rate on Power Transmission Tower-Line System under Seismic Excitation

    PubMed Central

    Wang, Wenming

    2014-01-01

    The effect analysis of strain rate on power transmission tower-line system under seismic excitation is studied in this paper. A three-dimensional finite element model of a transmission tower-line system is created based on a real project. Using theoretical analysis and numerical simulation, incremental dynamic analysis of the power transmission tower-line system is conducted to investigate the effect of strain rate on the nonlinear responses of the transmission tower and line. The results show that the effect of strain rate on the transmission tower generally decreases the maximum top displacements, but it would increase the maximum base shear forces, and thus it is necessary to consider the effect of strain rate on the seismic analysis of the transmission tower. The effect of strain rate could be ignored for the seismic analysis of the conductors and ground lines, but the responses of the ground lines considering strain rate effect are larger than those of the conductors. The results could provide a reference for the seismic design of the transmission tower-line system. PMID:25105157

  9. The effect analysis of strain rate on power transmission tower-line system under seismic excitation.

    PubMed

    Tian, Li; Wang, Wenming; Qian, Hui

    2014-01-01

    The effect analysis of strain rate on power transmission tower-line system under seismic excitation is studied in this paper. A three-dimensional finite element model of a transmission tower-line system is created based on a real project. Using theoretical analysis and numerical simulation, incremental dynamic analysis of the power transmission tower-line system is conducted to investigate the effect of strain rate on the nonlinear responses of the transmission tower and line. The results show that the effect of strain rate on the transmission tower generally decreases the maximum top displacements, but it would increase the maximum base shear forces, and thus it is necessary to consider the effect of strain rate on the seismic analysis of the transmission tower. The effect of strain rate could be ignored for the seismic analysis of the conductors and ground lines, but the responses of the ground lines considering strain rate effect are larger than those of the conductors. The results could provide a reference for the seismic design of the transmission tower-line system.

  10. 77 FR 35366 - Albany-Eugene Transmission Line Rebuild Project

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-13

    ...-pole structures and associated structural components and conductors, establishing better access to the line, improving access roads, developing staging areas for storage of materials, removing vegetation...

  11. Research on UAV Intelligent Obstacle Avoidance Technology During Inspection of Transmission Line

    NASA Astrophysics Data System (ADS)

    Wei, Chuanhu; Zhang, Fei; Yin, Chaoyuan; Liu, Yue; Liu, Liang; Li, Zongyu; Wang, Wanguo

    Autonomous obstacle avoidance of unmanned aerial vehicle (hereinafter referred to as UAV) in electric power line inspection process has important significance for operation safety and economy for UAV intelligent inspection system of transmission line as main content of UAV intelligent inspection system on transmission line. In the paper, principles of UAV inspection obstacle avoidance technology of transmission line are introduced. UAV inspection obstacle avoidance technology based on particle swarm global optimization algorithm is proposed after common obstacle avoidance technologies are studied. Stimulation comparison is implemented with traditional UAV inspection obstacle avoidance technology which adopts artificial potential field method. Results show that UAV inspection strategy of particle swarm optimization algorithm, adopted in the paper, is prominently better than UAV inspection strategy of artificial potential field method in the aspects of obstacle avoidance effect and the ability of returning to preset inspection track after passing through the obstacle. An effective method is provided for UAV inspection obstacle avoidance of transmission line.

  12. Transmission expansion with smart switching under demand uncertainty and line failures

    SciTech Connect

    Schumacher, Kathryn M.; Chen, Richard Li-Yang; Cohn, Amy E. M.

    2016-06-07

    One of the major challenges in deciding where to build new transmission lines is that there is uncertainty regarding future loads, renewal generation output and equipment failures. We propose a robust optimization model whose transmission expansion solutions ensure that demand can be met over a wide range of conditions. Specifically, we require feasible operation for all loads and renewable generation levels within given ranges, and for all single transmission line failures. Furthermore, we consider transmission switching as an allowable recovery action. This relatively inexpensive method of redirecting power flows improves resiliency, but introduces computational challenges. Lastly, we present a novel algorithm to solve this model. Computational results are discussed.

  13. Transmission expansion with smart switching under demand uncertainty and line failures

    SciTech Connect

    Schumacher, Kathryn M.; Chen, Richard Li-Yang; Cohn, Amy E. M.

    2016-06-07

    One of the major challenges in deciding where to build new transmission lines is that there is uncertainty regarding future loads, renewal generation output and equipment failures. We propose a robust optimization model whose transmission expansion solutions ensure that demand can be met over a wide range of conditions. Specifically, we require feasible operation for all loads and renewable generation levels within given ranges, and for all single transmission line failures. Furthermore, we consider transmission switching as an allowable recovery action. This relatively inexpensive method of redirecting power flows improves resiliency, but introduces computational challenges. Lastly, we present a novel algorithm to solve this model. Computational results are discussed.

  14. A planar transmission-line sensor for measuring microwave permittivity of liquid and semisolid biological materials

    USDA-ARS?s Scientific Manuscript database

    An accurate technique for determining the permittivity of biological materials with coplanar waveguide transmission line is presented. The technique utilizes closed-form approximations that relate the material permittivity to the line propagation constant. A thru-reflect-line calibration procedure i...

  15. Plasmonic transmission lines: from micro to nano scale with lambda/4 impedance matching.

    PubMed

    Ginzburg, Pavel; Orenstein, Meir

    2007-05-28

    The downscaling of conventional RF transmission lines methodologies to subwavelength plasmonic circuits is discussed and demonstrated for a lambda/4 transformer impedance matching. The nano-size transformer, matching between 0.5mum and 50nm wide plasmonic transmission lines, enhances the coupling efficiency by more than 285% compared to the direct ("end fire") coupling - i.e. harvesting more than 86% of total incident power. The influence of the transverse resonances induced by the metal claddings of the input transmission line on the light harvesting is discussed as well.

  16. The development of a portable, automatic, microwave transmission line test set

    NASA Astrophysics Data System (ADS)

    de La Fuente, Val; Karuschkat, Glenn; Simone, Frederick

    Existing test sets for flightline testing of microwave transmission lines are complex, semiportable systems requiring the piece-part testing of waveguides, antennas, and transmission line components in the aircraft. Moreover, these systems are not fully automated and require a large degree of manual intervention. Therefore, advances in test-set miniaturization and automatic control techniques can now be utilized to develop a fully portable, automatic test set for the flightline functional and diagnostic fault isolation testing of RF avionics and microwave transmission lines. A description is given of the proposed capabilities of such a tester, and the benefits expected to be derived from its use.

  17. 49 CFR 192.179 - Transmission line valves.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Design of Pipeline Components § 192.179 Transmission... be equipped with valves or other components to shut off the flow of gas to an offshore platform in an...

  18. Repetitive MEGAMP per microsecond di/dt pulsers for driving sub-ohm transmission line neutrino particle detectors

    SciTech Connect

    Krausse, G.J.; Dalton, C.G.; Sarjeant, J.

    1980-01-01

    With the advent of low-cost honeycomb extrusions of polypropylene sheets, transmission line flash chambers have become highly attractive candidates for large particle detector arrays. This has brought about the need for repetitive pulse systems that must provide exceptionally high peak currents, low levels of spurious radiation, high reliability, and shot life in excess of 10/sup 7/. Each module of 10 flash chambers requires a peak current of 20 kA with a current di/dt greater than 1 MA/..mu..s. The pulser output must develop approx. = 7 kV across a load of 0.5 ..cap omega.. with a pulse width of 500 ns. The complete system will require 40 pulsers run in parallel for a combined current output of 1.4 MA peak with a system di/dt of 40 MA/..mu..s. The repetition rate will be up to 2 Hz. This paper describes the development of such a system, its unique voltage and current diagnostics, and the impact of the physical limitations of present component technology on lifetime, reliability, maintainability, and pulse fidelity.

  19. A planar transmission-line sensor for measuring the microwave permittivity of liquid and semisolid biological materials

    USDA-ARS?s Scientific Manuscript database

    A planar transmission-line configuration for rapid, nondestructive, wideband permittivity measurements of liquid and semisolid materials at microwave frequencies is described. The transmission-line propagation constant of the proposed configuration is determined with the multiline technique from sca...

  20. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-127- Eugene-Alvey#2

    SciTech Connect

    Sherer, Brett M.

    2003-02-19

    BPA proposes to remove unwanted vegetation along the right-of-way, access roads, and around tower structures of the subject transmission line corridor that may impede the operation and maintenance of the identified transmission lines. BPA plans to conduct vegetation control with the goal of removing tall growing vegetation that is currently or will soon be a hazard to the transmission line. BPA’s overall goal is to have low-growing plant communities along the rights-of-way to control the development of potentially threatening vegetation. Vegetation Management for the Eugene-Alvey 115 kV transmission line from structure 7/1 through structure 12/2m, and along portions of the following adjacent transmission lines: Hawkins-Alvey 115KV and Alvey-Lane 115KV.

  1. High precision ultrasonic guided wave technique for inspection of power transmission line

    NASA Astrophysics Data System (ADS)

    Cheng, Jun; Qiu, Jinhao; Ji, Hongli; Wang, Enrong; Takagi, Toshiyuki; Uchimoto, Tetsuya

    2017-01-01

    Due to the merits of high inspection speed and long detecting distance, Ultrasonic Guided Wave(UGW) method has been commonly applied to the on-line maintenance of power transmission line. However, the guided wave propagation in this structure is very complicated, leading to the unfavorable defect localization accuracy. Aiming at this situation, a high precision UGW technique for inspection of local surface defect in power transmission line is proposed. The technique is realized by adopting a novel segmental piezoelectric ring transducer and transducer mounting scheme, combining with the comprehensive characterization of wave propagation and circumferential defect positioning with multiple piezoelectric elements. Firstly, the propagation path of guided waves in the multi-wires of transmission line under the proposed technique condition is investigated experimentally. Next, the wave velocities are calculated by dispersion curves and experiment test respectively, and from comparing of the two results, the guided wave mode propagated in transmission line is confirmed to be F(1,1) mode. Finally, the axial and circumferential positioning of local defective wires in transmission line are both achieved, by using multiple piezoelectric elements to surround the stands and send elastic waves into every single wire. The proposed research can play a role of guiding the development of highly effective UGW method and detecting system for multi-wire transmission line.

  2. Investigation of a Photoconductively Switched, Radial Transmission Line Accelerator

    DTIC Science & Technology

    1987-06-01

    that is due to insulator surface flashover in a vacuum. The radial line conductors can be oriented vertically and the structural supports and...possible voltage or electric field pulse to the acceleration gap. Presently, flashover of the vacuum side of the insulator separating the power system...supported by material surfaces . The photoconductively switched radial line accelerator power system is comparable to the -wake field- accelerator

  3. Performance analysis of radiation cooled dc transmission lines for high power space systems

    NASA Technical Reports Server (NTRS)

    Schwarze, G. E.

    1985-01-01

    As space power levels increase to meet mission objectives and also as the transmission distance between power source and load increases, the mass, volume, power loss, and operating voltage and temperature become important system design considerations. This analysis develops the dependence of the specific mass and percent power loss on the power and voltage levels, transmission distance, operating temperature and conductor material properties. Only radiation cooling is considered since the transmission line is assumed to operate in a space environment. The results show that the limiting conditions for achieving low specific mass, percent power loss, and volume for a space-type dc transmission line are the permissible transmission voltage and operating temperature. Other means to achieve low specific mass include the judicious choice of conductor materials. The results of this analysis should be immediately applicable to power system trade-off studies including comparisons with ac transmission systems.

  4. Performance analysis of radiation cooled dc transmission lines for high power space systems

    NASA Technical Reports Server (NTRS)

    Schwarze, G. E.

    1985-01-01

    As space power levels increase to meet mission objectives and also as the transmission distance between power source and load increases, the mass, volume, power loss, and operating voltage and temperature become important system design considerations. This analysis develops the dependence of the specific mass and percent power loss on hte power and voltage levels, transmission distance, operating temperature and conductor material properties. Only radiation cooling is considered since the transmission line is assumed to operate in a space environment. The results show that the limiting conditions for achieving low specific mass, percent power loss, and volume for a space-type dc transmission line are the permissible transmission voltage and operating temperature. Other means to achieve low specific mass include the judicious choice of conductor materials. The results of this analysis should be immediately applicable to power system trade-off studies including comparisons with ac transmission systems.

  5. 49 CFR 192.717 - Transmission lines: Permanent field repair of leaks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... encirclement welded split sleeve of appropriate design, unless the transmission line is joined by mechanical... method that reliable engineering tests and analyses show can permanently restore the serviceability of...

  6. 49 CFR 192.717 - Transmission lines: Permanent field repair of leaks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... encirclement welded split sleeve of appropriate design, unless the transmission line is joined by mechanical... method that reliable engineering tests and analyses show can permanently restore the serviceability of...

  7. Radio and television interference caused by corona discharges from high-voltage transmission lines

    SciTech Connect

    Sarmadi, M.

    1996-11-01

    Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions and generally increases by 10 to 30 dB in foul weather.

  8. Radio and television interference caused by corona discharges from high-voltage transmission lines

    SciTech Connect

    Sarmadi, M.

    1995-10-01

    Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions and generally increases by 10 to 30 dB in foul weather.

  9. PennsylvaniaNew Jersey Interconnection Bushkill to Roseland Transmission Line, From Roseland ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Pennsylvania-New Jersey Interconnection Bushkill to Roseland Transmission Line, From Roseland Borough, Essex County, through Morris County and Sussex County to Hardwick Township, Warren County, Roseland, Essex County, NJ

  10. MIDOT: A novel probe for monitoring high-current flat transmission lines

    NASA Astrophysics Data System (ADS)

    Omar, K.; Novac, B. M.; Graneau, N.; Senior, P.; Smith, I. R.; Sinclair, M.

    2016-12-01

    A novel inductive probe, termed MIDOT, was developed for monitoring high-current flat transmission lines. While being inexpensive the probe does not require calibration, is resistant to both shock waves and temperature variations, and it is easy to manufacture and mount. It generates strong output signals that are relatively easy to interpret and has a detection region limited to a pre-defined part of the transmission line. The theoretical background related to the MIDOT probes, together with their practical implementation in both preliminary experimentation and high-current tests, is also presented in the paper. The novel probe can be used to benchmark existing 2D numerical codes used in calculating the current distribution inside the conductors of a transmission line but can also easily detect an early movement of a transmission line component. The probe can also find other applications, such as locating the position of a pulsed current flowing through a thin wire.

  11. A distributed parameter model of transmission line transformer for high voltage nanosecond pulse generation

    NASA Astrophysics Data System (ADS)

    Li, Jiangtao; Zhao, Zheng; Li, Longjie; He, Jiaxin; Li, Chenjie; Wang, Yifeng; Su, Can

    2017-09-01

    A transmission line transformer has potential advantages for nanosecond pulse generation including excellent frequency response and no leakage inductance. The wave propagation process in a secondary mode line is indispensable due to an obvious inside transient electromagnetic transition in this scenario. The equivalent model of the transmission line transformer is crucial for predicting the output waveform and evaluating the effects of magnetic cores on output performance. However, traditional lumped parameter models are not sufficient for nanosecond pulse generation due to the natural neglect of wave propagations in secondary mode lines based on a lumped parameter assumption. In this paper, a distributed parameter model of transmission line transformer was established to investigate wave propagation in the secondary mode line and its influential factors through theoretical analysis and experimental verification. The wave propagation discontinuity in the secondary mode line induced by magnetic cores is emphasized. Characteristics of the magnetic core under a nanosecond pulse were obtained by experiments. Distribution and formation of the secondary mode current were determined for revealing essential wave propagation processes in secondary mode lines. The output waveform and efficiency were found to be affected dramatically by wave propagation discontinuity in secondary mode lines induced by magnetic cores. The proposed distributed parameter model was proved more suitable for nanosecond pulse generation in aspects of secondary mode current, output efficiency, and output waveform. In depth, comprehension of underlying mechanisms and a broader view of the working principle of the transmission line transformer for nanosecond pulse generation can be obtained through this research.

  12. Kv1 channels and neural processing in vestibular calyx afferents

    PubMed Central

    Meredith, Frances L.; Kirk, Matthew E.; Rennie, Katherine J.

    2015-01-01

    Potassium-selective ion channels are important for accurate transmission of signals from auditory and vestibular sensory end organs to their targets in the central nervous system. During different gravity conditions, astronauts experience altered input signals from the peripheral vestibular system resulting in sensorimotor dysfunction. Adaptation to altered sensory input occurs, but it is not explicitly known whether this involves synaptic modifications within the vestibular epithelia. Future investigations of such potential plasticity require a better understanding of the electrophysiological mechanisms underlying the known heterogeneity of afferent discharge under normal conditions. This study advances this understanding by examining the role of the Kv1 potassium channel family in mediating action potentials in specialized vestibular afferent calyx endings in the gerbil crista and utricle. Pharmacological agents selective for different sub-types of Kv1 channels were tested on membrane responses in whole cell recordings in the crista. Kv1 channels sensitive to α-dendrotoxin and dendrotoxin-K were found to prevail in the central regions, whereas K+ channels sensitive to margatoxin, which blocks Kv1.3 and 1.6 channels, were more prominent in peripheral regions. Margatoxin-sensitive currents showed voltage-dependent inactivation. Dendrotoxin-sensitive currents showed no inactivation and dampened excitability in calyces in central neuroepithelial regions. The differential distribution of Kv1 potassium channels in vestibular afferents supports their importance in accurately relaying gravitational and head movement signals through specialized lines to the central nervous system. Pharmacological modulation of specific groups of K+ channels could help alleviate vestibular dysfunction on earth and in space. PMID:26082693

  13. Development of Y-branch Joint for 275kV XLPE and Fluid Filled Cable

    NASA Astrophysics Data System (ADS)

    Goto, Takeshi; Yamashita, Makoto; Sakamaki, Masatoshi

    When a new UHV substation is built in an urban region, generally, an existing underground transmission line shall be diverted and drawn into the new substation. Compared with above mentioned construction method, enormous cost reduction of switching facilities and cable construction is expected with applying a Y-Branch Joint (YJ) which is able to be a 3-way joint. The YJ has already been applied for 154kV class circuit, however, it has not been investigated for 275kV class circuit. Since both XLPE and Fluid-Filled cable are presently used in 275kV class underground cable line, an universal design YJ for both cables have been investigated. The YJ was applied a compact design which was based on our sophisticated electrical stress control technology for 500kV prefabricated type joint. Furthermore, the design was based on its prefabricated assembling technology. The YJ was verified its electrical and mechanical performance as 275kV cable joint by completion of its assembling test and a long term electrical test.

  14. Multisection transmission line scatter function theory for measurements of soil dielectric properties

    USDA-ARS?s Scientific Manuscript database

    Vector network analyzers measure both reflection (S11) and transmission (S21) functions, but S21 has not been used to estimate soil dielectric permittivity independently. The objectives of this study were to: (1) derive the mathematical model for S21 of a multisection transmission line, and (2) tes...

  15. Optimized Minimal Inductance Transmission Line Configuration for Z-Pinch Experiments

    SciTech Connect

    Hurricane, O

    2003-10-16

    Successful dynamic Z-pinch experiments generally require good current delivery to the target load. Power flow losses through highly inductive transmission line configurations reduce the current available to the load. In this Brief Report, a variational calculus technique is used to determine the transmission line configuration that produces the least possible inductance and therefore the best possible current delivery for Z-pinch experiments.

  16. A Proposal for a High-Voltage Transmission Line Directional Coupler

    DOE PAGES

    Olsen, R. G.; Li, Zhi

    2017-02-01

    Directional couplers are devices generally used in high frequency transmission lines and waveguides that respond to forward and reverse traveling waves separately. Hence they can be used to either measure standing wave ratio in the steady state or to determine the direction of a propagating transient wave. Here, a design is proposed for a directional coupler to be used on multimode high voltage transmission lines. Its performance is analyzed and several suggestions are made for improving its design.

  17. Frequency Selective Properties of Coaxial Transmission Lines Loaded with Combined Artificial Inclusions

    PubMed Central

    2014-01-01

    The properties of a modified coaxial transmission line by periodic inclusions will be discussed. The introduction of split ring resonators, conductor stubs, air gaps, and combination of these gives rise to new frequency selective properties, such as stopband or passband behavior, observable in planar as well as volumetric metamaterial structures. These results envisage new potential applications and implementation of devices in coaxial transmission line technology. PMID:24587748

  18. Analysis of optimum diameter of orbit of transmission line source in positron emission tomograph

    SciTech Connect

    Yamamoto, S.; Amano, M.; Hirose, Y.; Muira, S.; Kanno, I.

    1989-02-01

    Accurate attenuation correction is one of the most important factors to achieve quantitative measurements in positron emission tomography (PET). A transmission scan is most commonly used technique for the attenuation correction in PET. A difficulty in transmission scan is relatively long period to obtain a data with good signal-to-noise ratio. Insufficient signal-to-noise ratio of the transmission data limits that of emission data. Several approaches were reported to improve the transmission data. Those were (1) optimizing of detector threshold, (2) processing delayed coincidence sinogram before subtraction, filtering of transmission sinogram before performing attenuation correction, and (3) rejection of random and scatter coincidence by using rotating line source and information of its position. In some of these methods, additional calculation time or processing hardware is needed. The authors have estimated a relationship between ring diameter of a transmission line source and signal to noise ratio of the transmission dat. This paper aimes to analyze optimum diameter of the orbit of transmission line source in concerning to signal to noise ratio in transmission data.

  19. Transmission line galloping image monitoring system based on digital signal processor

    NASA Astrophysics Data System (ADS)

    Ren, Hai Peng; Ma, Zhan Feng

    2011-06-01

    An embedded image monitoring system based on TMS320DM642 Digital Signal Processor (DSP) is proposed for the transmission line monitoring. The system can detect galloping, ice or snow covering, and other abnormal status of the transmission line in a real time mode. The image detection algorithms are compared using the controlled experiment under the complex weather environment, thereby, a set of image processing algorithms is proposed for transmission lines image monitoring. The DSP/BOIS multi-threaded programming techniques are used to realize the algorithm in the DSPs' embedded software. A wireless communication based on General Packet Radio Service (GPRS) module is designed to transmit the detection results and the changed information of the image to the monitoring center, so that the operators can get the real time status of the transmission line. The application of the system will play an important role in the condition-based maintenance of power transmission lines and improve the reliability of power delivery system. Transmission line; Status monitoring; Complex weather factor; Image filtering and sharpening; Image segment; Morphological filtering; Wireless communication; Digital signal processor; Multi-threaded programming.

  20. Analysis and characterization of high- Tc superconducting planar transmission lines for microwave circuit components

    SciTech Connect

    Kong Keonshik.

    1991-01-01

    A loss modeling of high {Tc} superconducting planar transmission lines is presented in this dissertation. Transmission structures such as microstrip lines, coplanar waveguides and conductor backed coplanar waveguides are investigated for implementation of a high-{Tc} superconductor. Also, short pulse propagation in the superconducting coplanar stripline is characterized. The motivation for this work is to provide an analytical basis for the effective application of a high {Tc} superconductor to planar transmission lines for microwave components. First, a loss characterization of the various high {Tc} superconducting microstrip line structures is presented in which either the strip or the ground plane is a high {Tc} superconductor. In the analysis, the internal impedances in the strip and the ground plane are separately calculated, and the total internal impedance is obtained by the superposition of the internal impedances. Next, the characteristic of a superconducting coplanar waveguide is investigated and compared with a superconducting microstrip line.