Sample records for l-1-13cphenylalanine breath tests

  1. Effect of alcohol consumption on the liver detoxication capacity as measured by [13C2]aminopyrine and L-[1-13C]phenylalanine breath tests.

    PubMed

    Wutzke, Klaus D; Wigger, Marianne

    2009-09-01

    The aim of this study was to investigate the hepatic microsomal and cytosolic functions by using the 13CO2 breath test in healthy subjects either before or after consumption of red wine. Twelve adults received [13C2]aminopyrine and L-[1-13C]phenylalanine together with a standardised dinner. Expired air samples were taken over 6 h. After a wash-out period, the subjects consumed 0.4 ml ethanol per kg per day together with dinner over a 7.5-day period on average. Thereafter, 13C-tracer administration was repeated under identical conditions. The 13CO2 enrichments were measured by isotope ratio mass spectrometry. The mean cumulative percentage 13C-dose recovery after administration of [13C2]aminopyrine and L-[1-13C]phenylalanine either without or with red wine consumption amounted to 17.0+/-4.4 vs. 14.7+/-3.1% (p=0.170) and 14.0+/-2.8 vs. 11.5+/-3.9% (p=0.084), respectively. Moderate alcohol consumption does not induce significant short-term changes of the microsomal and the cytosolic function of the human liver in healthy subjects.

  2. Clinical research on liver reserve function by 13C-phenylalanine breath test in aged patients with chronic liver diseases

    PubMed Central

    2010-01-01

    Background The objective of this study was to investigate whether the 13C-phenylalanine breath test could be useful for the evaluation of hepatic function in elderly volunteers and patients with chronic hepatitis B and liver cirrhosis. Methods L-[1-13C] phenylalanine was administered orally at a dose of 100 mg to 55 elderly patients with liver cirrhosis, 30 patients with chronic hepatitis B and 38 elderly healthy subjects. The breath test was performed at 8 different time points (0, 10, 20, 30, 45, 60, 90, 120 min) to obtain the values of Delta over baseline, percentage 13CO2 exhalation rate and cumulative excretion (Cum). The relationships of the cumulative excretion with the 13C-%dose/h and blood biochemical parameters were investigated. Results The 13C-%dose/h at 20 min and 30 min combined with the cumulative excretion at 60 min and 120 min correlated with hepatic function tests, serum albumin, hemoglobin, platelet and Child-Pugh score. Prothrombin time, total and direct bilirubin were significantly increased, while serum albumin, hemoglobin and platelet, the cumulative excretion at 60 min and 120 min values decreased by degrees of intensity of the disease in Child-Pugh A, B, and C patients (P < 0.01). Conclusions The 13C-phenylalanine breath test can be used as a non-invasive assay to evaluate hepatic function in elderly patients with liver cirrhosis. The 13C-%dose/h at 20 min, at 30 min and cumulative excretion at 60 min may be the key value for determination at a single time-point. 13C-phenylalanine breath test is safe and helpful in distinguishing different stages of hepatic dysfunction for elderly cirrhosis patients. PMID:20459849

  3. Measurement of hepatic functional mass by means of 13C-methacetin and 13C-phenylalanine breath tests in chronic liver disease: Comparison with Child-Pugh score and serum bile acid levels

    PubMed Central

    Festi, D.; Capodicasa, S.; Sandri, L.; Colaiocco-Ferrante, L.; Staniscia, T.; Vitacolonna, E.; Vestito, A.; Simoni, P.; Mazzella, G.; Portincasa, P.; Roda, E.; Colecchia, A.

    2005-01-01

    AIM: To evaluate and compare the clinical usefulness of 13C-phenylalanine and 13C-methacetin breath tests in quantitating functional hepatic mass in patients with chronic liver disease and to further compare these results with those of conventional tests, Child-Pugh score and serum bile acid levels. METHODS: One hundred and forty patients (50 HCV- related chronic hepatitis, 90 liver cirrhosis patients) and 40 matched healthy controls were studied. Both breath test and routine liver test, serum levels of cholic and chenodeoxycholic acid conjugates were evaluated. RESULTS: Methacetin breath test, expressed as 60 min cumulative percent of oxidation, discriminated the hepatic functional capacity not only between controls and liver disease patients, but also between different categories of chronic liver disease patients. Methacetin breath test was correlated with liver function tests and serum bile acids. Furthermore, methacetin breath test, as well as serum bile acids, were highly predictive of Child-Pugh scores. The diagnostic power of phenylalanine breath test was always less than that of methacetin breath test. CONCLUSION: Methacetin breath test represents a safe and accurate diagnostic tool in the evaluation of hepatic functional mass in chronic liver disease patients. PMID:15609414

  4. Evaluation of 13CO2 breath tests for the detection of fructose malabsorption.

    PubMed

    Hoekstra, J H; van den Aker, J H; Kneepkens, C M; Stellaard, F; Geypens, B; Ghoos, Y F

    1996-03-01

    Breath hydrogen (H2) studies have made clear that small intestinal absorption of fructose is limited, especially in toddlers. Malabsorption of fructose may be a cause of recurrent abdominal pain and chronic nonspecific diarrhea (toddler's diarrhea). Fructose absorption is facilitated by equimolar doses of glucose and, as we have found, amino acids (especially L-alanine); the mechanism underlying this effect remains unclear. To study fructose absorption in a more direct way, we combined breath H2 studies with breath 13CO2 studies. Gastric emptying was studied by using L-glycine-1-13C in 4 children from 12.1 to 16.0 years of age. After 25 gm of fructose and 27.5 gm of glucose, when given together, gastric emptying was significantly (p<0.05) slower than with either sugar alone. In a second series of experiments, 5 children from 12.0 to 15.9 years of age were tested with 25 gm of fructose, alone and with equimolar doses of glucose and L-alanine, and 4 younger children from 3.1 to 6.1 years of age were tested with 2 gm/kg (max 37.5 gm) fructose, alone or with an equimolar dose of L-alanine. All fructose solutions were enriched with 15 mg of D-fructose-13C-6. In all 9 children, fructose was malabsorbed as judged by breath H2 increases > or = 20 ppm, and the addition of glucose or L-alanine resulted in significantly lower breath H2 increases (p < or = 0.005 for glucose, p < or = 0.001 for alanine). In contrast, the addition of alanine or glucose did not change the pattern of breath 13CO2 excretion in the 5 older children, whereas in the 4 younger children (with relatively higher doses), L-alanine addition resulted in significantly lower increases in breath 13CO2. In the latter group, for each time point, breath H2 and 13CO2 concentrations after fructose were compared with those after fructose plus L-alanine; in 20 out of 24 points, both H2 and 13CO2 were higher after fructose. These results suggest that 13CO2 not only originated from the oxidation of absorbed substrate

  5. Optoacoustic 13C-breath test analyzer

    NASA Astrophysics Data System (ADS)

    Harde, Hermann; Helmrich, Günther; Wolff, Marcus

    2010-02-01

    The composition and concentration of exhaled volatile gases reflects the physical ability of a patient. Therefore, a breath analysis allows to recognize an infectious disease in an organ or even to identify a tumor. One of the most prominent breath tests is the 13C-urea-breath test, applied to ascertain the presence of the bacterium helicobacter pylori in the stomach wall as an indication of a gastric ulcer. In this contribution we present a new optical analyzer that employs a compact and simple set-up based on photoacoustic spectroscopy. It consists of two identical photoacoustic cells containing two breath samples, one taken before and one after capturing an isotope-marked substrate, where the most common isotope 12C is replaced to a large extent by 13C. The analyzer measures simultaneously the relative CO2 isotopologue concentrations in both samples by exciting the molecules on specially selected absorption lines with a semiconductor laser operating at a wavelength of 2.744 μm. For a reliable diagnosis changes of the 13CO2 concentration of 1% in the exhaled breath have to be detected at a concentration level of this isotope in the breath of about 500 ppm.

  6. New optical analyzer for 13C-breath test

    NASA Astrophysics Data System (ADS)

    Harde, Hermann; Dressler, Matthias; Helmrich, Günther; Wolff, Marcus; Groninga, Hinrich

    2008-04-01

    Medical breath tests are well established diagnostic tools, predominantly for gastroenterological inspections, but also for many other examinations. Since the composition and concentration of exhaled volatile gases reflect the physical condition of a patient, a breath analysis allows one to recognize an infectious disease in an organ or even to identify a tumor. One of the most prominent breath tests is the 13C-urea-breath test, applied to ascertain the presence of the bacterium helicobacter pylori in the stomach wall as an indication of a gastric ulcer. In this contribution we present a new optical analyzer that is based on photoacoustic spectroscopy and uses a DFB diode laser at 2.744 μm. The concentration ratio of the CO II isotopologues is determined by measuring the absorption on a 13CO II line in comparison to a 12CO II line. In the specially selected spectral range the lines have similar strengths, although the concentrations differ by a factor of 90. Therefore, the signals are well comparable. Due to an excellent signal-noise-ratio isotope variations of less than 1% can be resolved as required for the breath test.

  7. 13C-methacetin and 13C-galactose breath tests can assess restricted liver function even in early stages of primary biliary cirrhosis.

    PubMed

    Holtmeier, Julia; Leuschner, Maria; Schneider, Arne; Leuschner, Ulrich; Caspary, Wolfgang F; Braden, Barbara

    2006-11-01

    The 13C-methacetin breath test quantitatively evaluates cytochrome P450-dependent liver function. The 13C-galactose breath test non-invasively measures the galactose oxidation capacity of the liver. The aim of this study was to find out whether these breath tests are sensitive parameters also in non-cirrhotic patients with primary biliary cirrhosis. Nineteen patients with early-stage primary biliary cirrhosis (no cirrhotic alterations in the liver biopsy, Ludwig stage I-III) and 20 healthy controls underwent the 13C-methacetin and 13C-galactose breath tests. Patients with primary biliary cirrhosis metabolized less 13C-methacetin than controls (cumulative recovery within 30 min 7.5+/-2.4% versus 14.0+/-2.6%; p < 0.001). When a cut-off > 9.8% was used for the cumulative recovery after 30 min, the methacetin breath test reached 84.2% sensitivity and 95.0 specificity. In the 13C-galactose breath test, the percentage recovery at 60 min in patients was 3.1+/-1.3%/h, and 6.3+/-1.1%/h in controls (p < 0.001). Using a cut-off > 4.7%/h, the galactose breath test reached 89.5% sensitivity and 95.0 specificity. In non-cirrhotic, early-stage, primary biliary cirrhosis the 13C-methacetin breath test and the 13C-galactose breath test reliably indicate decreased liver function. The 13C-galactose breath test can also predict the histological score.

  8. An optimized 13C-urea breath test for the diagnosis of H pylori infection

    PubMed Central

    Campuzano-Maya, Germán

    2007-01-01

    AIM: To validate an optimized 13C-urea breath test (13C-UBT) protocol for the diagnosis of H pylori infection that is cost-efficient and maintains excellent diagnostic accuracy. METHODS: 70 healthy volunteers were tested with two simplified 13C-UBT protocols, with test meal (Protocol 2) and without test meal (Protocol 1). Breath samples were collected at 10, 20 and 30 min after ingestion of 50 mg 13C-urea dissolved in 10 mL of water, taken as a single swallow, followed by 200 mL of water (pH 6.0) and a circular motion around the waistline to homogenize the urea solution. Performance of both protocols was analyzed at various cut-off values. Results were validated against the European protocol. RESULTS: According to the reference protocol, 65.7% individuals were positive for H pylori infection and 34.3% were negative. There were no significant differences in the ability of both protocols to correctly identify positive and negative H pylori individuals. However, only Protocol 1 with no test meal achieved accuracy, sensitivity, specificity, positive and negative predictive values of 100%. The highest values achieved by Protocol 2 were 98.57%, 97.83%, 100%, 100% and 100%, respectively. CONCLUSION: A 10 min, 50 mg 13C-UBT with no test meal using a cut-off value of 2-2.5 is a highly accurate test for the diagnosis of H pylori infection at a reduced cost. PMID:17907288

  9. (13)C-Breath testing in animals: theory, applications, and future directions.

    PubMed

    McCue, Marshall D; Welch, Kenneth C

    2016-04-01

    The carbon isotope values in the exhaled breath of an animal mirror the carbon isotope values of the metabolic fuels being oxidized. The measurement of stable carbon isotopes in carbon dioxide is called (13)C-breath testing and offers a minimally invasive method to study substrate oxidation in vivo. (13)C-breath testing has been broadly used to study human exercise, nutrition, and pathologies since the 1970s. Owing to reduced use of radioactive isotopes and the increased convenience and affordability of (13)C-analyzers, the past decade has witnessed a sharp increase in the use of breath testing throughout comparative physiology--especially to answer questions about how and when animals oxidize particular nutrients. Here, we review the practical aspects of (13)C-breath testing and identify the strengths and weaknesses of different methodological approaches including the use of natural abundance versus artificially-enriched (13)C tracers. We critically compare the information that can be obtained using different experimental protocols such as diet-switching versus fuel-switching. We also discuss several factors that should be considered when designing breath testing experiments including extrinsic versus intrinsic (13)C-labelling and different approaches to model nutrient oxidation. We use case studies to highlight the myriad applications of (13)C-breath testing in basic and clinical human studies as well as comparative studies of fuel use, energetics, and carbon turnover in multiple vertebrate and invertebrate groups. Lastly, we call for increased and rigorous use of (13)C-breath testing to explore a variety of new research areas and potentially answer long standing questions related to thermobiology, locomotion, and nutrition.

  10. [Detection of Helicobacter pylori by culture and the 13C-urea breath test using an automated breath 13C analyzer].

    PubMed

    Yamamoto, Y; Kouda, M; Abe, K; Sakurabayashi, S; Sezai, S; Hirano, M; Oka, H

    1995-11-01

    Up to now, the diagnosis of H. pylori infection has been made by the breath test using 13C-urea. In this study, 13C-urea breath samples were tested in 34 patients (peptic ulcer scar 17, chronic gastritis 17 cases) with an automated breath 13C analyzer (ABCA. Europa Scientific, Crewe, UK) and compared with the results of endoscopical diagnosis for H. pylori infection. Endoscopic and 13C-urea breath test (13C-UBT) were performed before eradicative medication. We described a modified protocol for the growth grade of H. pylori colonies in microbiology (H. pylori score), and for the delta 13C area under curve (AUC; permil*hr) obtained from each sample of expired breath. There was a significant correlation between delta 13C-AUC and the delta 13C level of each sample, but the correlation coefficient obtained at 10min (R2 = 0.582) was lower than that obtained at the other four time points (20min; 0.891, 30min; 0.949, 40min; 0.946, 50min; 0.946, 60min; 0.820). The delta 13C-AUC well correlated with H. pylori score (p < 0.01), none of 26 H. pylori positive patients detected by culture was 13C-UBT negative (delta 13C-AUC < 8.2 permil*hr in mean + 2SD of H. pylori negative group). In conclusion, 13C-UBT using ABCA has high sensitivity and specificity, and it provides a non-invasive method for the detection of H. pylori urease activity.

  11. Does low dose (13)C-urea breath test maintain a satisfactory accuracy in diagnosing Helicobacter pylori infection?

    PubMed

    Coelho, Luiz Gonzaga Vaz; Silva, Arilto Eleutério da; Coelho, Maria Clara de Freitas; Penna, Francisco Guilherme Cancela e; Ferreira, Rafael Otto Antunes; Santa-Cecilia, Elisa Viana

    2011-01-01

    The standard doses of (13)C-urea in (13)C-urea breath test is 75 mg. To assess the diagnostic accuracy of (13)C-urea breath test containing 25 mg of (13)C-urea comparing with the standard doses of 75 mg in the diagnosis of Helicobacter pylori infection. Two hundred seventy adult patients (96 males, 174 females, median age 41 years) performed the standard (13)C-urea breath test (75 mg (13)C-urea) and repeated the (13)C-urea breath test using only 25 mg of (13)C-urea within a 2 week interval. The test was performed using an infrared isotope analyzer. Patients were considered positive if delta over baseline was >4.0‰ at the gold standard test. One hundred sixty-one (59.6%) patients were H. pylori negative and 109 (40.4%) were positive by the gold standard test. Using receiver operating characteristic analysis we established a cut-off value of 3.4% as the best value of 25 mg (13)C-urea breath test to discriminate positive and negative patients, considering the H. pylori prevalence (95% CI: 23.9-37.3) at our setting. Therefore, we obtained to 25 mg (13)C-urea breath test a diagnostic accuracy of 92.9% (95% CI: 88.1-97.9), sensitivity 83.5% (95% CI: 75.4-89.3), specificity 99.4% (95% CI: 96.6-99.9), positive predictive value 98.3% (95% CI: 92.4-99.4), and negative predictive value 93.0% (95% CI: 88.6-96.1). Low-dose (13)C-urea breath test (25 mg (13)C-urea) does not reach accuracy sufficient to be recommended in clinical setting where a 30% prevalence of H. pylori infection is observed. Further studies should be done to determine the diagnostic accuracy of low doses of (13)C-urea in the urea breath test.

  12. Follow-up of coeliac disease with the novel one-hour 13C-sorbitol breath test versus the H2-sorbitol breath test.

    PubMed

    Tveito, Kari; Hetta, Anne Kristine; Askedal, Mia; Brunborg, Cathrine; Sandvik, Leiv; Løberg, Else Marit; Skar, Viggo

    2011-07-01

    We recently developed a (13)C-sorbitol breath test ((13)C-SBT) as an alternative to the H(2)-sorbitol breath test (H(2)-SBT) for coeliac disease. In this study we compared the diagnostic properties of the H(2)-SBT and the (13)C-SBT in follow-up of coeliac disease. Twenty-seven coeliac patients on a gluten-free diet (GFD) performed the breath tests. All had been tested before treatment in the initial study of the (13)C-SBT, in which 39 untreated coeliac patients, 40 patient controls, and 26 healthy volunteers participated. Five gram sorbitol and 100 mg (13)C-sorbitol were dissolved in 250 ml tap water and given orally. H(2), CH(4) and (13)CO(2) were measured in end-expiratory breath samples every 30 min for 4 h. Increased H(2) concentration ≥20 ppm from basal values was used as cut-off for the H(2)-SBT. Sixty minutes values were used as diagnostic index in the (13)C-SBT. (13)CO(2) levels at 60 min increased in 20/26 treated coeliac patients (77%) after GFD, but were significantly lower than in control groups. Out of 20 patients who had a positive H(2)-SBT before GFD, 12 had a negative H(2)-SBT after GFD. Peak H(2) concentrations were not correlated with (13)C-SBT results. The study confirms the sensitivity of a one-hour (13)C-SBT for small intestinal malabsorption. The (13)C-SBT has superior diagnostic properties compared with the H(2)-SBT in follow-up of coeliac disease.

  13. Stability of (13) C-Urea Breath Test Samples Over Time in the Diagnosis of Helicobacter pylori.

    PubMed

    Perets, Tsachi Tsadok; Shporn, Einav; Boltin, Doron; Dickman, Ram; Niv, Yaron

    2016-05-01

    The accuracy and repeatability of breath test in the diagnosis of Helicobacter pylori infection have not been adequately investigated. Although it has been shown that storage for long periods does not affect the analysis results, no data are available on the effect of repetitive testing. In this study, our aim was to evaluate the repeatability of the analyses of breath samples at room temperature. A total of 202 positive breath samples were collected in duplicates, before and after administration of 75 mg (13) C- urea dissolved in 100 ml of orange juice. Breath test results were expressed as delta (13) CO2 . The cut-off value was 3.5 parts per thousand. Each sample was analyzed in a mass spectrometer 7, 14, 21, and 28 days after collection. The accuracy calculation was based on the comparison of the delta (13) CO2 obtained in the three consecutive weeks following the first test run to the delta (13) CO2 obtained in the first test run. Two hundred (99%), 197 (97.52%), and 196 (97%) of the 202 samples tested positive in the second, third, and fourth test runs, respectively. The accuracy of the delta (13) CO2 was 98.6%, 99.2%, and 96.7% in the three consecutive runs, respectively. Short-term storage of 1 month does not affect sample stability or the results of (13) C-urea breath tests in up to three consecutive repeats. © 2015 Wiley Periodicals, Inc.

  14. Does postprandial itopride intake affect the rate of gastric emptying? A crossover study using the continuous real time 13C breath test (BreathID system).

    PubMed

    Nonaka, Takashi; Kessoku, Takaomi; Ogawa, Yuji; Yanagisawa, Shogo; Shiba, Tadahiko; Sahaguchi, Takashi; Atsukawa, Kazuhiro; Takahashi, Hisao; Sekino, Yusuke; Iida, Hiroshi; Hosono, Kunihiro; Endo, Hiroki; Sakamoto, Yasunari; Koide, Tomoko; Takahashi, Hirokazu; Tokoro, Chikako; Abe, Yasunobu; Maeda, Shin; Nakajima, Atsushi; Inamori, Masahiko

    2011-01-01

    The aim of this study was to determine whether oral Itopride hydrochloride (itopride) intake might have any effect on the rate of gastric emptying, using a novel non-invasive technique for measuring the rate of gastric emptying, namely, the continuous real time 13C breath test (BreathID system: Exalenz Bioscience Ltd., Israel). Eight healthy male volunteers participated in this randomized, two-way crossover study. The subjects fasted overnight and were randomly assigned to receive 50mg itopride following a test meal (200 kcal per 200mL, containing 100mg 13C acetate), or the test meal alone. Under both conditions, gastric emptying was monitored for 4 hours after administration of the test meal by the 13C-acetic acid breath test performed continually using the BreathID system. Using Oridion Research Software (beta version), the time required for emptying of 50% of the labeled meal (T 1/2), the analog to the scintigraphy lag time for 10% emptying of the labeled meal (T lag), the gastric emptying coefficient (GEC), and the regression-estimated constants (beta and kappa) were calculated. The parameters measured under the two conditions were compared using the Wilcoxon's signed-rank test. No significant differences in the calculated parameters, namely, the T 1/2, T lag, GEC, beta or kappa, were observed between the two test conditions, namely, administration of a test meal+itopride and administration of the test meal alone. The present study revealed that postprandial itopride intake had no significant influence on the rate of gastric emptying. Recently, several studies have shown that itopride may be effective in the treatment of patients with functional dyspepsia. Our results suggest that the efficacy of itopride in patients with functional dyspepsia may be based on its effect of improving functions other than the rate of gastric emptying, such as the activities at neuronal sites, brain-gut correlation, visceral hypersensitivity, gastric accommodation and distension

  15. (13)C breath tests in personalized medicine: fiction or reality?

    PubMed

    Modak, Anil S

    2009-11-01

    The concept of personalized medicine is gathering momentum as various biomarkers are being discovered and developed to lead to genotype and phenotype diagnostic tests, which will enable physicians to individualize therapy. Noninvasive, rapid (13)C breath tests have the potential to serve as clinically significant diagnostic tools, especially for evaluating the enzyme activity of polymorphic enzymes. This would enable physicians to rapidly identify responders/nonresponders to various drugs primarily metabolized by these enzymes prior to initiation of therapy. With the information on enzyme activity, the physician can prescribe the right drug, at the right dose, at the right time, to the right individual, for the right clinical outcome. However, the promise of the era of personalized medicine, including the novel (13)C breath tests, will have to overcome several regulatory, business and financial hurdles for diagnostic tests to become part of routine mainstream clinical practice over the next decade.

  16. 13C-methacetin-breath test compared to also noninvasive biochemical blood tests in predicting hepatic fibrosis and cirrhosis in chronic hepatitis C.

    PubMed

    Dinesen, L; Caspary, W F; Chapman, R W; Dietrich, C F; Sarrazin, C; Braden, B

    2008-09-01

    The (13)C-methacetin-breath test and also several noninvasive blood tests comprising routine laboratory parameters have been proposed to predict fibrosis and cirrhosis in chronic hepatitis C. The aim of the study was to compare the diagnostic accuracy between these tests referring to hepatic histology as gold standard. 96 patients with chronic hepatitis C virus infection underwent percutaneous liver biopsy and the (13)C-methacetin-breath test. The Fibroindex, the aspartate aminotransferase to platelet ratio index , and the aspartate aminotransferase to alanine aminotransferase ratio were used as parameters for the staging of fibrosis. The main endpoint was the area under the characteristic curves for the diagnosis of advanced fibrosis (F3-F4) and cirrhosis (F4) according to the Batts Ludwig criteria. ROC analysis revealed a cut-off <14.6 per thousand best with 92.6% sensitivity and 84.1% specificity for the (13)C-methacetin-breath test, for the Fibroindex >1.82 70.4% sensitivity and 91.3% specificity, for the aspartate aminotransferase to platelet ratio >1.0 a 66.7% sensitivity and 75.4% specificity, and for the aspartate aminotransferase to alanine aminotransferase ratio >1.0 63.0% sensitivity and 59.4% specificity in predicting liver cirrhosis. The areas under the curve for the breath test, the Fibroindex, aspartate aminotransferase to platelet ratio and the aspartate aminotransferase to alanine aminotransferase ratio were 0.958, 0.845, 0.799, and 0.688, respectively, when predicting cirrhosis. For identifying patients with advanced fibrosis, the areas under the curve were 0.827, 0.804, 0.779, and 0.561, respectively. Discordances between Fibroindex (21%), aspartate aminotransferase to platelet ratio (29%) or aspartate aminotransferase to alanine aminotransferase ratio (37.6%) and liver biopsy were significantly more frequent than between (13)C-breath test (11.6%) and liver biopsy (P<0.05). The (13)C-methacetin-breath test is more reliable in predicting advanced

  17. Simplified 13C-urea breath test with a new infrared spectrometer for diagnosis of Helicobacter pylori infection.

    PubMed

    Chen, Tseng-Shing; Chang, Full-Young; Chen, Pang-Chi; Huang, Thomas W; Ou, Jonathan T; Tsai, Ming-Hung; Wu, Ming-Shiang; Lin, Jaw-Town

    2003-11-01

    Infrared spectrometry has correlated excellently with mass spectrometry in detecting the ratio of 13CO(2) to 12CO(2) in breath samples. The present study aimed to evaluate the accuracy of the 13C-urea breath test (13C-UBT) using a new model of infrared analyzer. A total of 600 patients who were undergoing upper endoscopy without receiving eradication therapy were entered into the study. Culture, histology, and rapid urease test on biopsies from the antrum and corpus of the stomach were used for the determination of Helicobacter pylori infection. Breath samples were collected before and 20 min after drinking 100 mg 13C-urea in 100 mL water. The optimal cutoff value was determined by the receiver operating characteristic curve. Of the 586 patients who were eligible for analysis, 369 were positive for H. pylori infection, 185 were negative for H. pylori infection, and 32 were indeterminate. When the appropriate cutoff value was set at 3.5 per thousand, a sensitivity of 97.8%, a specificity of 96.8% and an accuracy of 97.5% were obtained using the 13C-UBT. The accuracy of the 13C-UBT decreased when CO(2) concentration in the breath sample was <2%, as compared with > or = 2% (93.6%vs 97.7%), mainly because of a decrease in specificity (81.8%vs 97.7%). There were 2.7% of patients with Delta13CO(2) values that fell between 3.0-4.5 per thousand, in whom the risk of error was 47%. The 13C-UBT performed with infrared spectrometry is a highly sensitive, specific, and non-invasive method for the detection of H. pylori infection. The immediate availability of the test result and technical simplicity make it particularly effective in routine clinical practice.

  18. Usefulness of rectally administering [1-(13)C]-butyrate for breath test in patients with active and quiescent ulcerative colitis.

    PubMed

    Kato, Kimitoshi; Ishii, Yukimoto; Mizuno, Shigeaki; Sugitani, Masahiko; Asai, Satoshi; Kohno, Tadashi; Takahashi, Katsuyuki; Komuro, Sachiko; Iwamoto, Maho; Miyamoto, Shunpachi; Takayama, Tadatoshi; Arakawa, Yasuyuki

    2007-02-01

    Impaired butyrate metabolism plays a part in ulcerative colitis (UC). To assess the usefulness of measuring butyrate metabolism as an indication of inflammatory activity, we investigated the rate of butyrate metabolism by breath test after administering [1-(13)C]-butyrate rectally to patients with UC. Thirty-eight UC patients (22 active, 16 quiescent) and 15 healthy controls were given [1-(13)C]-butyrate enemas. The (13)CO2 production rate was measured by breath test using an infrared spectrometric analyzer. The quantity of expired (13)CO2 was significantly lower in the active than in the quiescent UC and control groups. Cumulative (13)CO2 production at 240 min showed significant negative correlations with the clinical activity index (r=-0.65, p<0.0001), endoscopic activity index (r=-0.63, p=0.0001) and histology (r=-0.71, p<0.0001) in the active UC group. The (13)CO2 production rate was significantly increased in the quiescent stage as compared with the active stage in six UC patients, in whom clinical remission was achieved, in accordance with improvements in the clinical activity index, the endoscopic activity index, histology and fecal butyrate concentrations. Significant inverse correlations between the cumulative (13)CO2 production rate and these three parameters were seen in these six UC patients assessed in both the active and quiescent stages. Measurement of expired (13)CO2 after rectally administering [1-(13)C]-butyrate in active and quiescent UC appears to be a promising and reliable method for evaluating disease activity and metabolic changes associated with amelioration of inflammation.

  19. Comparison of Accuracy Between 13C- and 14C-Urea Breath Testing: Is an Indeterminate-Results Category Still Needed?

    PubMed

    Charest, Mathieu; Bélair, Marc-André

    2017-06-01

    Helicobacter pylori infection is the leading cause of peptic ulcer disease. The purpose of this study was, first, to assess the difference in the distribution of negative versus positive results between the older 14 C-urea breath test and the newer 13 C-urea breath test and, second, to determine whether use of an indeterminate-results category is still meaningful and what type of results should trigger repeated testing. Methods: A retrospective survey was performed of all consecutive patients referred to our service for urea breath testing. We analyzed 562 patients who had undergone testing with 14 C-urea and 454 patients who had undergone testing with 13 C-urea. Results: In comparison with the wide distribution of negative 14 C results, negative 13 C results were distributed farther from the cutoff and were grouped more tightly around the mean negative value. Distribution analysis of the negative results for 13 C testing, compared with those for 14 C testing, revealed a statistically significant difference between the two. Within the 13 C group, only 1 patient could have been classified as having indeterminate results using the same indeterminate zone as was used for the 14 C group. This is significantly less frequent than what was found for the 14 C group. Discussion: Borderline-negative results do occur with 13 C-urea breath testing, although less frequently than with 14 C-urea breath testing, and we will be carefully monitoring differences falling between 3.0 and 3.5 %Δ. 13 C-urea breath testing is safe and simple for the patient and, in most cases, provides clearer positive or negative results for the clinician. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  20. Estimation of gastric pH in cynomolgus monkeys, rats, and dogs using [(13)C]-calcium carbonate breath test.

    PubMed

    Tobita, Kazuki; Inada, Makoto; Sato, Asuka; Sudoh, Kimiyoshi; Sato, Hitoshi

    2016-09-01

    The determination of gastric pH is important for the confirmation of efficacy of anti-secretory drugs. However, current methods for measurement of gastric pH provide significant stress to animals and humans. The objective of this study is to establish an easy and reliable gastric pH measurement method by determining (13)CO2 concentration in expired air of monkeys, dogs, and rats after oral administration of Ca(13)CO3. A correlation of (13)CO2 concentration determined by a Ca(13)CO3 breath test with gastric pH just before Ca(13)CO3 administration was analyzed in the 3 animal species. The equations and contribution ratios of regression line were calculated from logarithmic (13)CO2 concentrations at 15min after administration of Ca(13)CO3 using the linear regression analysis. The (13)CO2 concentration in the Ca(13)CO3 breath test was well correlated with the gastric pH just before Ca(13)CO3 administration in the 3 animal species (r=-0.977 to -0.952). The equations of regression line between the (13)CO2 concentration and the gastric pH in each animal species showed good contribution ratios (R(2)≥0.89). The Ca(13)CO3 breath test is an informative tool to estimate gastric pH in animals and will be applicable as a new noninvasive tool for patients with GERD/PPI-resistant symptoms. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  1. Nondispersive infrared spectrometry for 13CO2/12CO2-measurements: a clinically feasible analyzer for stable isotope breath tests in gastroenterology.

    PubMed

    Braden, B; Caspary, W F; Lembcke, B

    1999-06-01

    13C-urea breath tests have become clinical routine for the diagnosis of Helicobacter pylori infection and other isotope breath tests have been invented e.g. for gastric emptying or quantitative liver function testing. Recently, isotope-selective nondispersive infrared spectrometers (NDIRS) have been developed for the analysis of the 13CO2/12CO2-enrichment in breath. In this study, we prospectively tested the validity of a newly developed NDIRS in comparison to isotope ratio mass spectrometry (IRMS). 142 patients with dyspeptic symptoms were tested for Helicobacter pylori infection using the 13C-urea breath test. The isotope ratio analysis of the breath samples was performed in duplicate both using IRMS and NDIRS. The results of the baseline-corrected 13CO2-exhalation values between IRMS and NDIRS were in excellent agreement. The mean difference between both methods was 0.28 +/- 1.93 delta/1000. Evaluating the qualitative urea breath test results in reference to IRMS as the reference the NDIRS had a sensitivity of 97.8% and a specificity of 98.9%. The isotope-selective nondispersive infrared spectroscopy is going to become a reliable, but low-cost and easy-to-operate alternative to expensive isotope ratio mass spectrometry in the analysis of 13C-breath tests.

  2. A metabolic simulator for unmanned testing of breathing apparatuses in hyperbaric conditions.

    PubMed

    Frånberg, Oskar; Loncar, Mario; Larsson, Åke; Ornhagen, Hans; Gennser, Mikael

    2014-11-01

    A major part of testing of rebreather apparatuses for underwater diving focuses on the oxygen dosage system. A metabolic simulator for testing breathing apparatuses was built and evaluated. Oxygen consumption was achieved through catalytic combustion of propene. With an admixture of carbon dioxide in the propene fuel, the system allowed the respiratory exchange ratio to be set freely within human variability and also made it possible to increase test pressures above the condensation pressure of propene. The system was tested by breathing ambient air in a pressure chamber with oxygen uptake (Vo₂) ranging from 1-4 L · min(-1), tidal volume (VT) from 1-3 L, breathing frequency (f) of 20 and 25 breaths/min, and chamber pressures from 100 to 670 kPa. The measured end-tidal oxygen concentration (Fo₂) was compared to calculated end-tidal Fo₂. The largest average difference in end-tidal Fo₂during atmospheric pressure conditions was 0.63%-points with a 0.28%-point average difference during the whole test. During hyperbaric conditions with pressures ranging from 100 to 670 kPa, the largest average difference in Fo₂was 1.68%-points seen during compression from 100 kPa to 400 kPa and the average difference in Fo₂during the whole test was 0.29%-points. In combination with a breathing simulator simulating tidal breathing, the system can be used for dynamic continuous testing of breathing equipment with changes in VT, f, Vo2, and pressure.

  3. 13C-tryptophan breath test detects increased catabolic turnover of tryptophan along the kynurenine pathway in patients with major depressive disorder

    PubMed Central

    Teraishi, Toshiya; Hori, Hiroaki; Sasayama, Daimei; Matsuo, Junko; Ogawa, Shintaro; Ota, Miho; Hattori, Kotaro; Kajiwara, Masahiro; Higuchi, Teruhiko; Kunugi, Hiroshi

    2015-01-01

    Altered tryptophan–kynurenine (KYN) metabolism has been implicated in major depressive disorder (MDD). The l-[1-13C]tryptophan breath test (13C-TBT) is a noninvasive, stable-isotope tracer method in which exhaled 13CO2 is attributable to tryptophan catabolism via the KYN pathway. We included 18 patients with MDD (DSM-IV) and 24 age- and sex-matched controls. 13C-tryptophan (150 mg) was orally administered and the 13CO2/12CO2 ratio in the breath was monitored for 180 min. The cumulative recovery rate during the 180-min test (CRR0–180; %), area under the Δ13CO2-time curve (AUC; %*min), and the maximal Δ13CO2 (Cmax; %) were significantly higher in patients with MDD than in the controls (p = 0.004, p = 0.008, and p = 0.002, respectively). Plasma tryptophan concentrations correlated negatively with Cmax in both the patients and controls (p = 0.020 and p = 0.034, respectively). Our results suggest that the 13C-TBT could be a novel biomarker for detecting a subgroup of MDD with increased tryptophan–KYN metabolism. PMID:26524975

  4. [Examination of gastric emptying rate by means of 13C-octanoic acid breath test. Methods of the test for adults and results of the investigation of healthy volunteers].

    PubMed

    Bures, J; Kopácová, M; Vorísek, V; Bukac, J; Neumann, D; Rejchrt, S; Pozler, O; Douda, T; Zivný, P; Palicka, V

    2005-01-01

    13C-octanoic acid breath test (13C-OABT) is a simple, safe and non-invasive technique for measuring gastric emptying. However, the method has not been standardized yet. Aim of the study was to work up, introduce and evaluate our own method of the 13C-OABT for adults. Ten healthy volunteers entered the study (5 men, 5 women, mean age 32 years, 50 % Helicobacter pylori positive). Standard test meals (with 100 mg 13C-sodium octanoate) were used three times within 3 weeks. The same solid meal (1,178 kJ) for Tests 1 and 2 contained scrambled egg (+ 3 g oil), white bread (40 g), butter (10 g) and distilled water (200 ml). Semi-solid meal (1,020 kJ) for Test 3 contained milk pudding (200 g) and distilled water (200 ml). Duplicate breath samples were obtained before and every 15 minutes after eating the test meal during 255 minutes. Altogether 1,080 breath samples were analysed twice (isotope ratio mass spectrometry, AP2003 Analytical Precision, UK). To assess the half-life of elimination (t1/2 E), we modelled the process of elimination with the incomplete gamma-function, which has a convenient form for the empiric plotting of breath test data. Mean t1/2E was 136+/-10 minutes (Test 1), 134+/-14 (Test 2) and 123+/-16 minutes (Test 3). Clinical reproducibility of 13C-OABT in particular persons was 98.2% (18 breath samples series), 90.8 % (15 samples) and 87.1% (9 breath samples series). There was a significant correlation between Test 1 and Test 2 results (r=0.887, p<0.0001). Mean difference of duplicate breath sample analysis was 1.460 % (in 540 pairs), mean baseline one-day analysis difference was 0.0982 (99.9274% accuracy). In healthy volunteers, normal range of t1/2E is 110-160 minutes for solids and 91-155 minutes for semisolid test meal. Using our own computed mean time of intermediate metabolism of 13C-octanoic acid (76.5+/-7.5 minutes), gastric emptying half-time is 33.5-83.5 minutes for solids and 14.5-78.5 minutes for semisolid test meal in healthy volunteers. The

  5. Additional Value of CH4 Measurement in a Combined 13C/H2 Lactose Malabsorption Breath Test: A Retrospective Analysis

    PubMed Central

    Houben, Els; De Preter, Vicky; Billen, Jaak; Van Ranst, Marc; Verbeke, Kristin

    2015-01-01

    The lactose hydrogen breath test is a commonly used, non-invasive method for the detection of lactose malabsorption and is based on an abnormal increase in breath hydrogen (H2) excretion after an oral dose of lactose. We use a combined 13C/H2 lactose breath test that measures breath 13CO2 as a measure of lactose digestion in addition to H2 and that has a better sensitivity and specificity than the standard test. The present retrospective study evaluated the results of 1051 13C/H2 lactose breath tests to assess the impact on the diagnostic accuracy of measuring breath CH4 in addition to H2 and 13CO2. Based on the 13C/H2 breath test, 314 patients were diagnosed with lactase deficiency, 138 with lactose malabsorption or small bowel bacterial overgrowth (SIBO), and 599 with normal lactose digestion. Additional measurement of CH4 further improved the accuracy of the test as 16% subjects with normal lactose digestion and no H2-excretion were found to excrete CH4. These subjects should have been classified as subjects with lactose malabsorption or SIBO. In conclusion, measuring CH4-concentrations has an added value to the 13C/H2 breath test to identify methanogenic subjects with lactose malabsorption or SIBO. PMID:26371034

  6. Validation of 13C-acetic acid breath test by measuring effects of loperamide, morphine, mosapride, and itopride on gastric emptying in mice.

    PubMed

    Matsumoto, Kenjiro; Kimura, Hiroshi; Tashima, Kimihito; Uchida, Masayuki; Horie, Syunji

    2008-10-01

    Several methods are used to evaluate gastric motility in rodents, but they all have technical limitations. Recent technical developments enable a convenient method to evaluate gastric motility. The (13)C-acetic acid breath test in rodents is a non-invasive and repeatable method that can be used without physical restraints. The present study aimed to validate the (13)C-acetic acid breath test by measuring the effects of loperamide, morphine, mosapride, and itopride on gastric emptying in mice. Loperamide (1-10 mg/kg) and morphine (1.25-10 mg/kg) slowed gastric emptying and decreased the maximum concentration (C(max)) and area under the curve (AUC(90 min)) value in a dose-dependent manner. Mosapride (0.2-5 mg/kg) accelerated gastric emptying and increased C(max) value. Mosapride (20 mg/kg) did not accelerate gastric emptying on the (13)C-breath test. Itopride (30 mg/kg, per os) significantly accelerated gastric emptying compared with the vehicle group. In a comparison with the conventional phenol red test, there was a correlation between the C(max) value of breath test and gastric emptying (%) of phenol red tests in treatment with loperamide or mosapride. These results indicate that the (13)C-acetic acid breath test is an accurate, noninvasive, and simple method for monitoring gastric emptying in mice. This method is useful to assess the effect of drugs and gut function pharmacologically.

  7. Investigation of Metabolism of Exogenous Glucose at the Early Stage and Onset of Diabetes Mellitus in Otsuka Long-Evans Tokushima Fatty Rats Using [1, 2, 3-13C]Glucose Breath Tests

    PubMed Central

    Kijima, Sho; Tanaka, Hideki

    2016-01-01

    This study aimed to evaluate changes in glucose metabolism at the early stage and onset of diabetes in Otsuka Long-Evans Tokushima Fatty (OLETF) rats. Specifically, after the oral administration of [1, 2, 3-13C]glucose, the levels of exhaled 13CO2, which most likely originated from pyruvate decarboxylation and tricarboxylic acid, were measured. Eight OLETF rats and eight control rats (Long-Evans Tokushima Otsuka [LETO]) were administered 13C-glucose. Three types of 13C-glucose breath tests were performed thrice in each period at 2-week intervals. [3-13C]glucose results in a 13C isotope at position 1 in the pyruvate molecule, which provides 13CO2. The 13C at carbons 1 and 2 of glucose is converted to 13C at carbons 2 and 1 of acetate, respectively, which produce 13CO2. Based on metabolic differences of the labeled sites, glucose metabolism was evaluated using the results of three breath tests. The increase in 13CO2 excretion in OLETF rats was delayed in all three breath tests compared to that in control rats, suggesting that OLETF rats had a lower glucose metabolism than control rats. In addition, overall glucose metabolism increased with age in both groups. The utilization of [2-13C]glucose was suppressed in OLETF rats at 6–12 weeks of age, but they showed higher [3-13C]glucose oxidation than control rats at 22–25 weeks of age. In the [1-13C]glucose breath test, no significant differences in the area under the curve until 180 minutes (AUC180) were observed between OLETF and LETO rats of any age. Glucose metabolism kinetics were different between the age groups and two groups of rats; however, these differences were not significant based on the overall AUC180 of [1-13C]glucose. We conclude that breath 13CO2 excretion is reduced in OLETF rats at the primary stage of prediabetes, indicating differences in glucose oxidation kinetics between OLETF and LETO rats. PMID:27483133

  8. Investigation of Metabolism of Exogenous Glucose at the Early Stage and Onset of Diabetes Mellitus in Otsuka Long-Evans Tokushima Fatty Rats Using [1, 2, 3-13C]Glucose Breath Tests.

    PubMed

    Kawagoe, Naoyuki; Kano, Osamu; Kijima, Sho; Tanaka, Hideki; Takayanagi, Masaaki; Urita, Yoshihisa

    2016-01-01

    This study aimed to evaluate changes in glucose metabolism at the early stage and onset of diabetes in Otsuka Long-Evans Tokushima Fatty (OLETF) rats. Specifically, after the oral administration of [1, 2, 3-13C]glucose, the levels of exhaled 13CO2, which most likely originated from pyruvate decarboxylation and tricarboxylic acid, were measured. Eight OLETF rats and eight control rats (Long-Evans Tokushima Otsuka [LETO]) were administered 13C-glucose. Three types of 13C-glucose breath tests were performed thrice in each period at 2-week intervals. [3-13C]glucose results in a 13C isotope at position 1 in the pyruvate molecule, which provides 13CO2. The 13C at carbons 1 and 2 of glucose is converted to 13C at carbons 2 and 1 of acetate, respectively, which produce 13CO2. Based on metabolic differences of the labeled sites, glucose metabolism was evaluated using the results of three breath tests. The increase in 13CO2 excretion in OLETF rats was delayed in all three breath tests compared to that in control rats, suggesting that OLETF rats had a lower glucose metabolism than control rats. In addition, overall glucose metabolism increased with age in both groups. The utilization of [2-13C]glucose was suppressed in OLETF rats at 6-12 weeks of age, but they showed higher [3-13C]glucose oxidation than control rats at 22-25 weeks of age. In the [1-13C]glucose breath test, no significant differences in the area under the curve until 180 minutes (AUC180) were observed between OLETF and LETO rats of any age. Glucose metabolism kinetics were different between the age groups and two groups of rats; however, these differences were not significant based on the overall AUC180 of [1-13C]glucose. We conclude that breath 13CO2 excretion is reduced in OLETF rats at the primary stage of prediabetes, indicating differences in glucose oxidation kinetics between OLETF and LETO rats.

  9. Right recumbent position on gastric emptying of water evidenced by 13C breath testing

    PubMed Central

    Sanaka, Masaki; Urita, Yoshihisa; Yamamoto, Takatsugu; Shirai, Tsuguru; Kimura, Satoshi; Aoyagi, Hitoshi; Kuyama, Yasushi

    2013-01-01

    AIM: To compare the impact of the right recumbent position with the sitting position on gastric emptying of water. METHODS: In eight healthy male volunteers, the 13C acetate breath test was performed twice to assess gastric emptying of 100 mL tap water. Subjects were seated in one test and lying on their right side in the other. In both positions, pulmonary 13CO2 exhalation curves were obtained by plotting breath data against time. Percent gastric retention curves were created by analyzing data using the Wagner-Nelson protocol. RESULTS: No significant posture effect was found in pulmonary 13CO2 output curves (P = 0.2150), whereas a significant effect was seen in gastric retention curves (P = 0.0315). The percent retention values at 10 min and 15 min were significantly smaller when subjects were in the right recumbent position compared with the seated position (P < 0.05). Our results verified the accelerating effect of the right recumbent position on gastric emptying of non-nutritive solutions. Concerning clinical implications, this study suggests that placing patients with acute pain on their right side after oral administration of analgesic drugs in solution is justified as an effective practice for rapid pain relief. For patients with gastrointestinal reflux symptoms, sleeping in the right recumbent position may reduce nocturnal symptoms, as delayed gastric emptying can cause reflux symptoms. CONCLUSION: Gastric emptying of water occurs more quickly when a subject lies on the right side compared with sitting. PMID:23372358

  10. Incorporation of sup 14 C from ( sup 14 C)phenylalanine into condensed tannin of sorghum grain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reddy, V.; Butler, L.G.

    A procedure is described for obtaining condensed tannin from sorghum (Sorghum bicolor (L.) Moench) seeds metabolically labeled from ({sup 14}C)phenylalanine. The ({sup 14}C)tannin should be useful in determining the metabolic fate of dietary condensed tannin.

  11. Hepatobiliary MRI: Signal intensity based assessment of liver function correlated to 13C-Methacetin breath test.

    PubMed

    Haimerl, Michael; Probst, Ute; Poelsterl, Stefanie; Beyer, Lukas; Fellner, Claudia; Selgrad, Michael; Hornung, Matthias; Stroszczynski, Christian; Wiggermann, Philipp

    2018-06-13

    Gadoxetic acid (Gd-EOB-DTPA) is a paramagnetic MRI contrast agent with raising popularity and has been used for evaluation of imaging-based liver function in recent years. In order to verify whether liver function as determined by real-time breath analysis using the intravenous administration of 13 C-methacetin can be estimated quantitatively from Gd-EOB-DTPA-enhanced MRI using signal intensity (SI) values. 110 patients underwent Gd-EOB-DTPA-enhanced 3-T MRI and, for the evaluation of liver function, a 13 C-methacetin breath test ( 13 C-MBT). SI values from before (SI pre ) and 20 min after (SI post ) contrast media injection were acquired by T1-weighted volume-interpolated breath-hold examination (VIBE) sequences with fat suppression. The relative enhancement (RE) between the plain and contrast-enhanced SI values was calculated and evaluated in a correlation analysis of 13 C-MBT values to SI post and RE to obtain a SI-based estimation of 13 C-MBT values. The simple regression model showed a log-linear correlation of 13 C-MBT values with SI post and RE (p < 0.001). Stratified by 3 different categories of 13 C-MBT readouts, there was a constant significant decrease in both SI post (p ≤ 0.002) and RE (p ≤ 0.033) with increasing liver disease progression as assessed by the 13 C-MBT. Liver function as determined using real-time 13 C-methacetin breath analysis can be estimated quantitatively from Gd-EOB-DTPA-enhanced MRI using SI-based indices.

  12. Lactose (mal)digestion evaluated by the 13C-lactose digestion test.

    PubMed

    Vonk, R J; Lin, Y; Koetse, H A; Huang, C; Zeng, G; Elzinga, H; Antoine, J; Stellaard, F

    2000-02-01

    The prevalence of genetically determined lactase nonpersistence is based on the results of the lactose H2 breath test. This test, however, is an indirect test, which might lead to misinterpretation. We determined lactase activity in healthy Chinese and Dutch students using a novel 13C-lactose digestion test. The cut-off value of this test was established in a Chinese population with a homogenous genetic background of lactase nonpersistence and was compared with the results obtained in a Caucasian population. Twenty-five grams of a 13C-lactose solution was consumed by 12 known H2-positive and 5 H2-negative Chinese students and 48 Dutch students and, subsequently, 13C-glucose concentration in plasma and H2 excretion in breath were measured. A similar 13C-glucose response curve was found in all Chinese students. The mean response curve in the Dutch students was more pronounced (P < 0.01). The 1 h (peak) plasma 13C-glucose concentration was the best discriminator between lactose digesting and maldigesting subjects. The cut-off level of 2 mmol L-1 13C-glucose in plasma was defined in the H2-positive Chinese students group. Based on the 13C-glucose response the prevalence of lactose maldigestion in the Dutch subjects was 25%; based on the lactose H2 breath test 17%. Using the 13C-lactose digestion test the results demonstrate a higher prevalence of lactose maldigestion in a Caucasian population than indicated by the results of the H2 breath test. A moderate increase in the plasma 13C-glucose concentration after consumption of 13C-lactose in the young adult Chinese subjects indicates a residual lactase activity in that age group, even when a positive H2 breath test result is obtained. These results indicate that the 13C-glucose concentration in plasma more accurately reflects the small intestinal lactose digestion capacity than the lactose H2 breath test.

  13. In vivo assessment of the mitochondrial response to caloric restriction in obese women by the 2-keto[1-C]isocaproate breath test.

    PubMed

    Parra, Dolores; González, Alvaro; Martínez, J Alfredo; Labayen, Idoia; Díez, Nieves

    2003-04-01

    The 2-keto[1-(13)C]isocaproate breath test has been proposed as a tool to detect mitochondrial dysfunction in alcoholic liver disease. The aim of this study was to evaluate if the 2-keto[1-(13)C]isocaproate breath test could detect in vivo dynamic changes on mitochondrial activity due to caloric restriction in obese women. Fifteen obese women (body mass index [BMI] > 30 kg/m(2)) participated in the study at baseline. Ten of these women agreed to participate on a diet program to induce body weight loss. Fifteen lean women (BMI < 25 kg/m(2)) were included as a control group. The breath test was performed by the oral administration of the tracer measuring (13)CO(2) enrichment in breath before and after ingestion using isotope ratio mass spectrometry. Body composition, resting energy expenditure, and plasma levels of insulin and leptin were measured. There were no relationships observed between the 2-keto[1-(13)C]isocaproate breath test and the plasma insulin (before diet: P =.863; after diet: P =.879), or leptin (before diet: P =.500; after diet: P =.637). In obese women before treatment, kilograms of fat free mass (P =.108), resting energy expenditure adjusted for body composition (P =.312), and the 2-keto[1-(13)C]isocaproate breath test (P =.205) were similar in comparison to lean women. However, 2-keto[1-(13)C]isocaproate oxidation tended to increase after dieting and was significantly higher than in controls (P =.015). These data suggest that the 2-keto[1-(13)C]isocaproate breath test reflected the adaptive modifications in mitochondrial oxidation in response to caloric restriction in obese women. Copyright 2003 Elsevier, Inc. All rights reserved.

  14. [13C]Glucose Breath Testing Provides a Noninvasive Measure of Insulin Resistance: Calibration Analyses Against Clamp Studies

    PubMed Central

    Hussain, Maysa; Jangorbhani, Morteza; Schuette, Sally; Considine, Robert V.; Chisholm, Robin L.

    2014-01-01

    Abstract Background: Exhaled 13CO2 following ingestion of [13C]glucose with a standard oral glucose tolerance load correlates with blood glucose values but is determined by tissue glucose uptake. Therefore exhaled 13CO2 may also be a surrogate measure of the whole-body glucose disposal rate (GDR) measured by the gold standard hyperinsulinemic euglycemic clamp. Subjects and Methods: Subjects from across the glycemia range were studied on 2 consecutive days under fasting conditions. On Day 1, a 75-g oral glucose load spiked with [13C]glucose was administered. On Day 2, a hyperinsulinemic euglycemic clamp was performed. Correlations between breath parameters and clamp-derived GDR were evaluated, and calibration analyses were performed to evaluate the precision of breath parameter predictions of clamp measures. Results: Correlations of breath parameters with GDR and GDR per kilogram of fat-free mass (GDRffm) ranged from 0.54 to 0.61 and 0.54 to 0.66, respectively (all P<0.001). In calibration analyses the root mean square error for breath parameters predicting GDR and GDRffm ranged from 2.32 to 2.46 and from 3.23 to 3.51, respectively. Cross-validation prediction error (CVPE) estimates were 2.35–2.51 (GDR) and 3.29–3.57 (GDRffm). Prediction precision of breath enrichment at 180 min predicting GDR (CVPE=2.35) was superior to that for inverse insulin (2.68) and the Matsuda Index (2.51) but inferior to that for the log of homeostasis model assessment (2.21) and Quantitative Insulin Sensitivity Check Index (2.29) (all P<10−5). Similar patterns were seen for predictions of GDRffm. Conclusions: 13CO2 appearance in exhaled breath following a standard oral glucose load with added [13C]glucose provides a valid surrogate index of clamp-derived measures of whole-body insulin resistance, with good accuracy and precision. This noninvasive breath test-based approach can provide a useful measure of whole-body insulin resistance in physiologic and epidemiologic studies. PMID

  15. A novel 13C-urea breath test device for the diagnosis of Helicobacter pylori infection: continuous online measurements allow for faster test results with high accuracy.

    PubMed

    Israeli, Eran; Ilan, Yaron; Meir, Shimon Bar; Buenavida, Claudia; Goldin, Eran

    2003-08-01

    The aim of this study is to determine the accuracy of a novel laptop sized 13C-Urea breath test analyzer that continuously measures expired breath and to use its advantages to decrease testing time. One hundred and eighty-six subjects (mean age of 47.8 years) were tested simultaneously by the BreathID system (Oridion, Israel), and by the traditional IRMS. BreathID continuously measured the expired breath for a ratio of 13CO(2):12CO(2.) This value was expressed as delta over baseline (DOB) and displayed graphically on a screen in real time. One hundred and one subjects were positive and 85 were negative for H. pylori by isotope ratio mass spectrometry (IRMS). The correlation for the BreathID system at 30 minutes was 100% for positive cases and 98% for negative cases. Analysis of the continuous curves generated by the BreathID for all patients permitted definition of different DOB thresholds for a positive or negative result at shorter time intervals. Thus, after 6 minutes a conclusive test result could be obtained for 64% of subjects, and after 10 minutes for 92% of subjects. The 13C-Urea breath test utilizing the technology of molecular correlation spectrometry is an accurate method for determining infection by H. pylori. The advantage of continuous measurements can shorten testing time without compromising accuracy.

  16. The Wagner-Nelson method can generate an accurate gastric emptying flow curve from CO2 data obtained by a 13C-labeled substrate breath test.

    PubMed

    Sanaka, Masaki; Yamamoto, Takatsugu; Ishii, Tarou; Kuyama, Yasushi

    2004-01-01

    In pharmacokinetics, the Wagner-Nelson (W-N) method can accurately estimate the rate of drug absorption from its urinary elimination rate. A stable isotope (13C) breath test attempts to estimate the rate of absorption of 13C, as an index of gastric emptying rate, from the rate of pulmonary elimination of 13CO2. The time-gastric emptying curve determined by the breath test is quite different from that determined by scintigraphy or ultrasonography. In this report, we have shown that the W-N method can adjust the difference. The W-N equation to estimate gastric emptying from breath data is as follows: the fractional cumulative amount of gastric contents emptied by time t = Abreath (t)/Abreath (infinity) + (1/0.65).d[Abreath (t)/Abreath (infinity) ]/dt, where Abreath (t) = the cumulative recovery of 13CO2 in breath by time t and Abreath ( infinity ) = the ultimate cumulative 13CO2 recovery. The emptying flow curve generated by ultrasonography was compared with that generated by the W-N method-adjusted breath test in 6 volunteers. The emptying curves by the W-N method were almost identical to those by ultrasound. The W-N method can generate an accurate emptying flow curve from 13CO2 data, and it can adjust the difference between ultrasonography and the breath test. Copyright 2004 S. Karger AG, Basel

  17. 13C-Breath Tests for Sucrose Digestion in Congenital Sucrase Isomaltase Deficient and Sacrosidase Supplemented Patients

    PubMed Central

    Robayo-Torres, Claudia C.; Opekun, Antone R.; Quezada-Calvillo, Roberto; Xavier, Villa; Smith, E. O’Brian; Navarrete, Marilyn; Baker, S. Susan; Nichols, Buford L

    2008-01-01

    Congenital sucrase-isomaltase deficiency (CSID) is characterized by absence or deficiency of the mucosal sucrase-isomaltase enzyme. Specific diagnosis requires upper gastrointestinal biopsy with evidence of low to absent sucrase enzyme activity and normal histology. The hydrogen breath test (BT) is useful but is not specific for confirmation of CSID. We investigated a more specific 13C-sucrose labeled BT. Objectives were to determine if CSID can be detected with the 13C-sucrose BT without duodenal biopsy sucrase assay and if the 13C-sucrose BT can document restoration of sucrose digestion by CSID patients after oral supplementation with sacrosidase (Sucraid®). Methods Ten CSID patients were diagnosed by low biopsy sucrase activity. Ten controls were children who underwent endoscopy and biopsy because of dyspepsia or chronic diarrhea with normal mucosal enzymes activity and histology. Uniformly-labeled 13C-glucose and 13C-sucrose loads were orally administered. 13CO2 breath enrichments were assayed using an infrared spectrophotometer. In CSID patients the 13C-sucrose load was repeated adding Sucraid®. Sucrose digestion and oxidation were calculated as a mean % coefficient of glucose oxidation (% CGO) averaged between 30 and 90 minutes. Results Classification of patients by 13C-sucrose BT % CGO agreed with biopsy sucrase activity. The breath test also documented the return to normal of sucrose digestion and oxidation after supplementation of CSID patients with Sucraid®. Conclusion 13C-sucrose BT is an accurate and specific non-invasive confirmatory test for CSID and for enzyme replacement management. PMID:19330928

  18. Cost-effectiveness of the Carbon-13 Urea Breath Test for the Detection of Helicobacter Pylori

    PubMed Central

    Masucci, L; Blackhouse, G; Goeree, R

    2013-01-01

    Objectives This analysis aimed to evaluate the cost-effectiveness of various testing strategies for Helicobacter pylori in patients with uninvestigated dyspepsia and to calculate the budgetary impact of these tests for the province of Ontario. Data Sources Data on the sensitivity and specificity were obtained from the clinical evidence-based analysis. Resource items were obtained from expert opinion, and costs were applied on the basis of published sources as well as expert opinion. Review Methods A decision analytic model was constructed to compare the costs and outcomes (false-positive results, false-negative results, and misdiagnoses avoided) of the carbon-13 (13C) urea breath test (UBT), enzyme-linked immunosorbent assay (ELISA) serology test, and a 2-step strategy of an ELISA serology test and a confirmatory 13C UBT based on the sensitivity and specificity of the tests and prevalence estimates. Results The 2-step strategy is more costly and more effective than the ELISA serology test and results in $210 per misdiagnosis case avoided. The 13C UBT is dominated by the 2-step strategy, i.e., it is more costly and less effective. The budget impact analysis indicates that it will cost $7.9 million more to test a volume of 129,307 patients with the 13C UBT than with ELISA serology, and $4.7 million more to test these patients with the 2-step strategy. Limitations The clinical studies that were pooled varied in the technique used to perform the breath test and in reference standards used to make comparisons with the breath test. However, these parameters were varied in a sensitivity analysis. The economic model was designed to consider intermediate outcomes only (i.e., misdiagnosed cases) and was not a complete model with final patient outcomes (e.g., quality-adjusted life years). Conclusions Results indicate that the 2-step strategy could be economically attractive for the testing of H. pylori. However, testing with the 2-step strategy will cost the Ministry of

  19. 13C-Mixed Triglyceride Breath Test and Fecal Elastase as an Indirect Pancreatic Function Test in Cystic Fibrosis Infants.

    PubMed

    Kent, Dorothea Stark; Remer, Thomas; Blumenthal, Caron; Hunt, Sharon; Simonds, Sharon; Egert, Sarah; Gaskin, Kevin J

    2018-05-01

    The 'gold standard' test for the indirect determination of pancreatic function status in infants with cystic fibrosis (CF), the 72-hour fecal fat excretion test, is likely to become obsolete in the near future. Alternative indirect pancreatic function tests with sufficient sensitivity and specificity to determine pancreatic phenotype need further evaluation in CF infants. Evaluation of the clinical utility of both the noninvasive, nonradioactive C-mixed triglyceride (MTG) breath test and fecal elastase-1 (FE1) in comparison with the 72-hour fecal fat assessment in infants with CF. C-MTG breath test and the monoclonal and polyclonal FE1 assessment in stool was compared with the 72-hour fecal fat assessment in 24 infants with CF. Oral pancreatic enzyme substitution (PERT; if already commenced) was stopped before the tests. Sensitivity rates between 82% and 100% for CF patients with pancreatic insufficiency assessed by both the C-MTG breath test and the FE1 tests proved to be high and promising. The C-MTG breath test (31%-38%) as well as both FE1 tests assessed by the monoclonal (46%-54%) and the polyclonal (45%) ELISA kits, however, showed unacceptably low-sensitivity rates for the detection of pancreatic-sufficient CF patients in the present study. The C-MTG breath test with nondispersive infrared spectroscopy (NDIRS) technique, as well as both FE1 tests, are not alternatives to the fecal fat balance test for the evaluation of pancreatic function in CF infants during the first year of life.

  20. The effect of breath freshener strips on two types of breath alcohol testing instruments.

    PubMed

    Moore, Ronald L; Guillen, Jennifer

    2004-07-01

    The potential for breath freshener strips to interfere with the accuracy of a breath alcohol test was studied. Twelve varieties of breath freshener strips from five manufacturers were examined. Breath tests were conducted using the infrared based BAC DataMaster or the fuel cell based Alco-Sensor IV-XL, 30 and 150 seconds after placing a breath strip on the tongue. No effect was observed using the Alco-Sensor system. Some of the strips gave a small reading at 30 seconds (less than or equal to 0.010 g/210 L apparent alcohol) using the DataMaster. Readings on the DataMaster returned to zero by the 150 second test. A proper pre-test observation and deprivation period should prevent any interference from breath freshener strips on breath alcohol testing.

  1. 13CO2 breath test to measure the hydrolysis of various starch formulations in healthy subjects.

    PubMed Central

    Hiele, M; Ghoos, Y; Rutgeerts, P; Vantrappen, G; de Buyser, K

    1990-01-01

    13CO2 starch breath test was used to study the effect of physicochemical characteristics of starch digestion. As starch is hydrolysed to glucose, which is subsequently oxidised to CO2, differences in 13CO2 excretion after ingestion of different starch products must be caused by differences in hydrolysis rate. To study the effect of the degree of chain branching, waxy starch, containing 98% amylopectin, was compared with high amylose starch, containing 30% amylopectin, and normal crystalline starch, containing 74% amylopectin. The effect of the extent of gelatinisation was studied by comparing extruded starch and crystalline starch. Finally, the possible inhibitory effect of adding wheat fibre to extruded starch on the hydrolysis rate was studied. The 13CO2 excretion from two to four hours after intake of crystalline starch was significantly lower than that of extruded starch. Waxy starch was hydrolysed much faster than high amylose starch, but there was no significant difference between waxy starch and normal crystalline starch. Addition of wheat fibre did not influence the hydrolysis rate. The 13CO2 starch breath test is an attractive test for the study of factors affecting carbohydrate assimilation. PMID:2107133

  2. Hydrogen breath test in schoolchildren.

    PubMed Central

    Douwes, A C; Schaap, C; van der Klei-van Moorsel, J M

    1985-01-01

    The frequency of negative hydrogen breath tests due to colonic bacterial flora which are unable to produce hydrogen was determined after oral lactulose challenge in 98 healthy Dutch schoolchildren. There was a negative result in 9.2%. The probability of a false normal lactose breath test (1:77) was calculated from these results together with those from a separate group of children with lactose malabsorption (also determined by hydrogen breath test). A study of siblings and mothers of subjects with a negative breath test did not show familial clustering of this condition. Faecal incubation tests with various sugars showed an increase in breath hydrogen greater than 100 parts per million in those with a positive breath test while subjects with a negative breath test also had a negative faecal incubation test. The frequency of a false negative hydrogen breath test was higher than previously reported, but this does not affect the superiority of this method of testing over the conventional blood glucose determination. PMID:4004310

  3. Performance of the 13C-urea breath test for the diagnosis of H. pylori infection using a substrate synthesized in Brazil: A preliminary study.

    PubMed

    Coelho, Luiz Gonzaga; Sant'Ana, Carlos Roberto; Oliveira, Ricardo Brandt de; Cezar, Raíra César E; Araujo, Aline Cordeiro Campos de; Silva, Raisa Cristina Teodoro da; Trindade, Osmar Reni; Coelho, Maria Clara; Ferrioli, Eduardo; Bendassolli, José Albertino

    2018-06-07

    The 13C-urea breath test is the main non-invasive test for the diagnosis of Helicobacter pylori infection. The availability of this test throughout the country is limited, mainly due to the difficulty in obtaining the labeled isotope from abroad. Recently, researchers from the Nuclear Energy Center in Agriculture at the University of São Paulo (CENA/USP) succeeded in synthesizing 13C-enriched urea for Helicobacter pylori diagnosis. The aim of the study was to compare the performance of the 13C-urea breath test using 13C-urea acquired abroad with that of a test using 13C-urea synthesized in Brazil. Sixty-four dyspeptic patients participated in the study (24 men and 40 women). Initially, the patients performed the 13C-urea breath test using the imported substrate (Euriso-Top, France). Seven to fourteen days later, all the patients repeated the test using the Brazilian substrate. The samples from both examinations were processed in an infrared isotope analyzer (IRIS, Wagner Analisen Technik, Germany), and all delta over baseline (DOB) [%] values above four were considered positive results. Twenty-seven patients (42%) exhibited negative results for Helicobacter pylori infection, and thirty-seven patients (58%) exhibited positive results when tested using the foreign substrate (gold standard). There was a 100% concordance regarding the presence or absence of infection when the gold standard results were compared with those obtained using the Brazilian substrate. Similar performance in the diagnosis of Helicobacter pylori infection was demonstrated when using the 13C-urea breath test with the Brazilian 13C-urea substrate and the test with the substrate produced abroad. This validation represents an important step toward increasing the availability of the 13C-urea breath test throughout the country, which will have a positive influence on the management of Helicobacter pylori infection.

  4. 13C-sodium acetate breath test for evaluation of gastric emptying times in dogs with gastric dilatation-volvulus.

    PubMed

    Schmitz, S; Jansen, N; Failing, K; Neiger, R

    2013-01-01

    The aim of the study was to assess solid phase gastric emptying via non-invasive 13C-sodium acetate breath test in large breed dogs with or without gastric dilatation-volvulus (GDV). Dogs were recruited into one of the following groups: group 1 = healthy large breed dogs with no history of GDV, group 2 = dogs that underwent elective abdominal surgery for reasons unrelated to the gastrointestinal tract, and group 3 = dogs that underwent laparotomy and gastropexy to correct GDV. The dogs were fed a test meal containing 100 mg 13C-sodium acetate (for group 2 and 3, this was < 48 hours post-operatively). Breath samples were obtained at baseline and every 30 minutes for 3 hours, then every hour for a total of 7 hours. 12CO2/13CO2 ratio was measured for each breath sample via non-dispersive infrared spectroscopy and 25%, 50% and 75% gastric emptying times were calculated and compared between groups. Gastric emptying times were significantly prolonged in dogs undergoing surgery (group 2) compared to group 1 and 3. Also, gastric emptying times of dogs with GDV were significantly prolonged compared to controls, but not to the same extent as dogs in group 2. There was a significant effect of abdominal surgery on gastric emptying times. Surprisingly, dogs after GDV surgery and gastropexy had shorter gastric emptying times than dogs undergoing laparotomy for reasons other than GDV, but still prolonged compared to healthy controls. The reason for these differences requires further study.

  5. Effects of homeopathic mother tinctures on breath alcohol testing.

    PubMed

    Boatto, Gianpiero; Trignano, Claudia; Burrai, Lucia; Spanu, Andrea; Nieddu, Maria

    2015-01-01

    In some countries, it is illegal to drive with any detectable amount of alcohol in blood; in others, the legal limit is 0.5 g/L or lower. Recently, some defendants charged with driving under the influence of alcohol and have claimed that positive breath alcohol test results were due to the ingestion of homeopathic mother tinctures. These preparations are obtained by maceration, digestion, infusion, or decoction of herbal material in hydroalcoholic solvent. A series of tests were conducted to evaluate the alcoholic content of three homeopathic mother tinctures and their ability to produce inaccurate breath alcohol results. Nine of 30 subjects gave positive results (0.11-0.82 g/L) when tests were taken within 1 min after drinking mother tincture. All tests taken at least 15 min after the mother tincture consumption and resulted in alcohol-free readings. An observation period of 15-20 min prior to breath alcohol testing eliminates the possibility of false-positive results. © 2014 American Academy of Forensic Sciences.

  6. Evaluation of the 13C-octanoate breath test as a surrogate marker of liver damage in animal models.

    PubMed

    Shalev, Tamar; Aeed, Hussein; Sorin, Vladimir; Shahmurov, Mark; Didkovsky, Elena; Ilan, Yaron; Avni, Yona; Shirin, Haim

    2010-06-01

    Octanoate (also known as sodium octanoate), a medium-chain fatty acid metabolized in the liver, is a potential substrate for non-invasive breath testing of hepatic mitochondrial beta-oxidation. We evaluated the 13C-octanoate breath test (OBT) for assessing injury in acute hepatitis and two rat models of liver cirrhosis, first testing octanoate absorption (per os or intraperitoneally (i.p.)) in normal rats. We then induced acute hepatitis with thioacetamide (300 mg/kg/i.p., 24-h intervals). Liver injury end points were serum aminotransferase levels and 13C-OBT (24 and 48 h following initial injection). Thioacetamide (200 mg/kg/i.p., twice per week, 12 weeks) was used to induce liver cirrhosis. OBT and liver histological assessment were performed every 4 weeks. Bile duct ligation (BDL) was used to induce cholestatic liver injury. We completed breath tests with 13C-OBT and 13C-methacetin (MBID), liver biochemistry, and liver histology in BDL and sham-operated rats (baseline, 6, 14, 20 days post-BDL). Octanoate absorbs well by either route. Peak amplitudes and cumulative percentage dose recovered at 30 and 60 min (CPDR30/60), but not peak time, correlated with acute hepatitis. Fibrosis stage 3 at week 8 significantly correlated with each OBT parameter. Cholestatic liver injury (serum bilirubin, ALP, gamma-GT, liver histology) was associated with significant suppression of the maximal peak values and CPDR30/60, respectively (P<0.05),using MBID but not 13C-octanoate. OBT is sensitive for potentially evaluating liver function in rat models of acute hepatitis and thioacetamide-induced liver cirrhosis but not in cholestatic liver injury. The MBID test may be better for evaluation of cholestatic liver disease in this model.

  7. Influence of the 13C-enrichment of the habitual diet on a 13CO2 breath test used as an index of liver glycogen oxidation: a validation study in western Europe and Africa.

    PubMed

    Tanis, A A; Rietveld, T; Van den Berg, J W; Wattimena, J L; Swart, G R

    2000-01-01

    A diet containing naturally 13C-enriched carbohydrate combined with a 13CO2 breath-test analysis can be used to monitor liver glycogen oxidation in persons used to a diet low in 13C, e.g., the Western European diet. In this study, we evaluated this test principle further by changing the way we label the glycogen pool. The 13C enrichment of exhaled CO2 was studied in two groups, one in Europe and one in Africa. The European group (n = 12) was accustomed to a diet low in 13C, and they went on a 13C-enriched study diet to identify liver glycogen. The African group (n = 6) was accustomed to a diet naturally high in 13C, and they went on a diet low in 13C. The basal 13C abundance in exhaled CO2 was higher in the African group (1.0879 At%; atmospheric 1.1 atom percent) than in the European group (1.0821 At%). During the study period, the parameters for liver glycogen oxidation--the 13CO2 enrichment plateau, the plateau duration, and the return to baseline time--did not differ between groups. The abundance of 13CO2 in exhaled CO2 over time in the two groups was similar but inverse. This study confirms the use of a 13CO2 breath test to monitor liver glycogen oxidation and demonstrates how to use such a test in persons accustomed to a diet high in 13C.

  8. [Reliability study on the infrared spectrometry for measuring the delta over baseline for breath 13C].

    PubMed

    Wang, Min; Wang, Zhiling; Gou, Lingyan; Zhang, Yuhui; Yang, Xiaoguang; Sha, Lei; Li, Min

    2013-03-01

    To assess the validity and reliability of the infrared spectrometry for measuring the delta over baseline for breath 13C. Twenty-four healthy adults were selected, including twelve males and twelve females. 13C-Leucine was used as tracer in stable isotope metabolic experiments. One baseline breath was collected before the tracer protocol began. Other breath samples were collected at 60, 120, 180, 195, 210, 225, 240, 255, 270 and 300 min post-tracer challenge. The delta over baseline for breath 13C was measured by the infrared spectrometry and Heliview 13C breath analyzer. No significant differences were found between the infrared spectrometry and Heliview 13C breath analyzer in measuring the delta over baseline for breath 13C. The F value and p value of two-way ANOVA were 0.29 and 0.5874 respectively. The t and p value of consistency test were 0.48 and 0.6346 respectively. The 13C infrared spectrometry can reliably measure the delta over baseline for breath 13C.

  9. Gastric emptying of solids in children: reference values for the (13) C-octanoic acid breath test.

    PubMed

    Hauser, B; Roelants, M; De Schepper, J; Veereman, G; Caveliers, V; Devreker, T; De Greef, E; Vandenplas, Y

    2016-10-01

    (99m) Technetium scintigraphy ((99m) TS) is the 'gold standard' for measuring gastric emptying (GE), but it is associated with a radiation exposure. For this reason, the (13) C-octanoic acid breath test ((13) C-OBT) was developed for measuring GE of solids. The objective of this study was to determine normal values for gastric half-emptying time (t1/2 GE) of solids in healthy children. Gastric emptying of a standardized solid test meal consisting of a pancake evaluated with (99m) TS and (13) C-OBT was compared in 22 children aged between 1 and 15 years with upper gastrointestinal symptoms. Subsequently, the (13) C-OBT was used to determine normal values for GE of the same solid test meal in 120 healthy children aged between 1 and 17 years. The results showed a significant correlation (r = 0.748, p = 0.0001) between t1/2 GE measured with both techniques in the group of children with upper gastrointestinal symptoms. In the group of healthy children, mean t1/2 GE was 157.7 ± 54.0 min (range 71-415 min), but t1/2 GE decreased with age between 1 and 10 years and remained stable afterward. There was no influence of gender, weight, height, body mass index, and body surface area on t1/2 GE. Normal values for GE of solids measured with the (13) C-OBT using a standardized methodology were determined in healthy children. We propose to use this method and corresponding reference ranges to study GE of solids in children with gastrointestinal problems. © 2016 John Wiley & Sons Ltd.

  10. Substantial Differences between Organ and Muscle Specific Tracer Incorporation Rates in a Lactating Dairy Cow

    PubMed Central

    Burd, Nicholas A.; Hamer, Henrike M.; Pennings, Bart; Pellikaan, Wilbert F.; Senden, Joan M. G.; Gijsen, Annemie P.; van Loon, Luc J. C.

    2013-01-01

    We aimed to produce intrinsically L-[1-13C]phenylalanine labeled milk and beef for subsequent use in human nutrition research. The collection of the various organ tissues after slaughter allowed for us to gain insight into the dynamics of tissue protein turnover in vivo in a lactating dairy cow. One lactating dairy cow received a constant infusion of L-[1-13C]phenylalanine (450 µmol/min) for 96 h. Plasma and milk were collected prior to, during, and after the stable isotope infusion. Twenty-four hours after cessation of the infusion the cow was slaughtered. The meat and samples of the various organ tissues (liver, heart, lung, udder, kidney, rumen, small intestine, and colon) were collected and stored. Approximately 210 kg of intrinsically labeled beef (bone and fat free) with an average L-[1-13C]phenylalanine enrichment of 1.8±0.1 mole percent excess (MPE) was obtained. The various organ tissues differed substantially in L-[1-13C]phenylalanine enrichments in the tissue protein bound pool, the highest enrichment levels were achieved in the kidney (11.7 MPE) and the lowest enrichment levels in the skeletal muscle tissue protein of the cow (between 1.5–2.4 MPE). The estimated protein synthesis rates of the various organ tissues should be regarded as underestimates, particularly for the organs with the higher turnover rates and high secretory activity, due to the lengthened (96 h) measurement period necessary for the production of the intrinsically labeled beef. Our data demonstrates that there are relatively small differences in L-[1-13C]phenylalanine enrichments between the various meat cuts, but substantial higher enrichment values are observed in the various organ tissues. We conclude that protein turnover rates of various organs are much higher when compared to skeletal muscle protein turnover rates in large lactating ruminants. PMID:23826365

  11. Procedures in the 13C octanoic acid breath test for measurement of gastric emptying: analysis using Bland-Altman methods.

    PubMed

    Clegg, Miriam E; Shafat, Amir

    2010-08-01

    The (13)C octanoic acid breath test (OBT) was first developed as an alternative method of measuring gastric emptying (GE) to scintigraphy. There has been much debate about the test duration and how often measurements need to be taken. This study aims to address these issues. For 78 GE tests using the (13)C OBT, GE lag phase (T(lag)) was calculated while sampling more frequently than the recommended every 15 min. Comparisons between T(lag) were completed using Bland-Altman plots. Similarly, 4 or 6 h test durations were assessed to establish if they yield the same GE half time (T(half)). From one volunteer, samples were taken every 1 min for the first 30 min and then every 15 min until 6 h. GE times were then calculated using different combinations of sampling times. Evidence of a visible T(lag) was also explored from this data. Findings indicated that taking samples every 5 min for the first 30 min instead of every 15 min did not change the GE T(lag) based on Bland-Altman plots. The correlation between these two methods was also high (r(2) = 0.9957). The findings showed that the difference between the two sampling durations 4 and 6 h was large and the correlation between the methods was low (r(2) = 0.8335). Samples taken at a rate of one breath per min indicated lack of a visible T(lag). Sampling for the (13)C OBT should be completed every 15 min for 6 h.

  12. Synthesis of ¹³C-lidocaine as a probe of breath test for the evaluation of cytochrome P450 activity.

    PubMed

    Mitome, Hidemichi; Sugiyama, Erika; Sato, Hitoshi; Akira, Kazuki

    2014-01-01

    (13)C-Labeled lidocaine, 2-di[1-(13)C]ethylamino-N-(2,6-dimethylphenyl)acetamide (1), was synthesized from [1-(13)C]acetic acid in six steps, as a probe for a breath test to evaluate in vivo cytochrome P450 activity. The measurement of (13)CO2 in breath was successfully performed following oral administration of (13)C-lidocaine 1 to mice.

  13. Effects of Ergot Alkaloids on Liver Function of Piglets as Evaluated by the 13C-Methacetin and 13C-α-Ketoisocaproic Acid Breath Test

    PubMed Central

    Dänicke, Sven; Diers, Sonja

    2013-01-01

    Ergot alkaloids (the sum of individual ergot alkaloids are termed as total alkaloids, TA) are produced by the fungus Claviceps purpurea, which infests cereal grains commonly used as feedstuffs. Ergot alkaloids potentially modulate microsomal and mitochondrial hepatic enzymes. Thus, the aim of the present experiment was to assess their effects on microsomal and mitochondrial liver function using the 13C-Methacetin (MC) and 13C-α-ketoisocaproic acid (KICA) breath test, respectively. Two ergot batches were mixed into piglet diets, resulting in 11 and 22 mg (Ergot 5-low and Ergot 5-high), 9 and 14 mg TA/kg (Ergot 15-low and Ergot 15-high) and compared to an ergot-free control group. Feed intake and live weight gain decreased significantly with the TA content (p < 0.001). Feeding the Ergot 5-high diet tended to decrease the 60-min-cumulative 13CO2 percentage of the dose recovery (cPDR60) by 26% and 28% in the MC and KICA breath test, respectively, compared to the control group (p = 0.065). Therefore, both microsomal and mitochondrial liver function was slightly affected by ergot alkaloids. PMID:23322130

  14. Effects of ergot alkaloids on liver function of piglets as evaluated by the (13)C-methacetin and (13)C-α-ketoisocaproic acid breath test.

    PubMed

    Dänicke, Sven; Diers, Sonja

    2013-01-15

    Ergot alkaloids (the sum of individual ergot alkaloids are termed as total alkaloids, TA) are produced by the fungus Claviceps purpurea, which infests cereal grains commonly used as feedstuffs. Ergot alkaloids potentially modulate microsomal and mitochondrial hepatic enzymes. Thus, the aim of the present experiment was to assess their effects on microsomal and mitochondrial liver function using the (13)C-Methacetin (MC) and (13)C-α-ketoisocaproic acid (KICA) breath test, respectively. Two ergot batches were mixed into piglet diets, resulting in 11 and 22 mg (Ergot 5-low and Ergot 5-high), 9 and 14 mg TA/kg (Ergot 15-low and Ergot 15-high) and compared to an ergot-free control group. Feed intake and live weight gain decreased significantly with the TA content (p < 0.001). Feeding the Ergot 5-high diet tended to decrease the 60-min-cumulative (13)CO(2) percentage of the dose recovery (cPDR(60)) by 26% and 28% in the MC and KICA breath test, respectively, compared to the control group (p = 0.065). Therefore, both microsomal and mitochondrial liver function was slightly affected by ergot alkaloids.

  15. 42 CFR 84.88 - Breathing bag test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Apparatus § 84.88 Breathing bag test. (a) Breathing bags will be tested in an air atmosphere saturated with... Institute upon request. (d) The air within the bag(s) shall not contain more than 100 parts per million of... 42 Public Health 1 2014-10-01 2014-10-01 false Breathing bag test. 84.88 Section 84.88 Public...

  16. Measurement of starch digestion of naturally 13C-enriched weaning foods, before and after partial digestion with amylase-rich flour, using a 13C breath test.

    PubMed

    Weaver, L T; Dibba, B; Sonko, B; Bohane, T D; Hoare, S

    1995-10-01

    Malnutrition in infancy is a global problem which leads to retardation of childhood growth and development. There is a pressing need to improve weaning strategies for infants of the developing world. Traditional Gambian weaning foods are watery and of low energy density, but addition of energy in the form of fat and carbohydrate leads to thick, viscous gruels which are difficult to ingest. Partial digestion with amylase (EC 3.2.1.1)-rich flour reduces their viscosity while retaining their energy density. The aim of the present study was to measure the digestibility of a maize-based weaning food, before and after amylase digestion, in malnourished children using a 13C breath test. Ten children (aged 7-16 months; mean weight-for-age Z score -0.8) received isovolumetric and isoenergetic quantities of a maize-based weaning food naturally abundant with 13C. Breath samples were collected at intervals of 30 min for 5 h thereafter and 13CO2 enrichment was measured by isotope-ratio mass spectrometry. Percentage dose of 13C recovered increased from a mean 13.7 (SD 3.7)% before, to 18.3 (SD 5.6)% after ingestion of amylase-treated weaning foods (P < 0.1). There was a significant inverse relation between age and weight, and percentage dose of 13C recovered in children receiving amylase-treated feeds. There were no differences in concentrations of amylase in saliva of infants or breast milk of their mothers. Partial digestion of supplementary foods may improve the nutrition of undernourished weaning children, not only by reducing their viscosity, thereby increasing ingestion, but also by improving their digestion and thereby their absorption.

  17. Influence of different proton pump inhibitors on activity of cytochrome P450 assessed by [(13)C]-aminopyrine breath test.

    PubMed

    Kodaira, Chise; Uchida, Shinya; Yamade, Mihoko; Nishino, Masafumi; Ikuma, Mutsuhiro; Namiki, Noriyuki; Sugimoto, Mitsushige; Watanabe, Hiroshi; Hishida, Akira; Furuta, Takahisa

    2012-03-01

    Aminopyrine is metabolized by cytochrome P450 (CYP) in the liver. The investigators evaluated influences of different PPIs on CYP activity as assessed by the [(13)C]-aminopyrine breath test ([(13)C]-ABT). Subjects were 15 healthy volunteers with different CYP2C19 status (5 rapid metabolizers [RMs], 5 intermediate metabolizers [IMs], and 5 poor metabolizers [PMs]). Breath samples were collected before and every 15 to 30 minutes for 3 hours after oral ingestion of [(13)C]-aminopyrine 100 mg on day 8 of each of the following regimens: control; omeprazole 20 mg and 80 mg, lansoprazole 30 mg, and rabeprazole 20 mg. Changes in carbon isotope ratios in carbon dioxide ((13)CO(2)/(12)CO(2)) in breath samples were measured by infrared spectrometry and expressed as delta-over-baseline (DOB) ratios (‰). Mean areas under the curve of DOB from 0 to 3 h (AUC(0-3h) of DOB) were significantly decreased by omeprazole 20 mg and lansoprazole 30 mg but not by rabeprazole 20 mg. Conversely, higher PPI dose (ie, omeprazole 80 mg) seemed to further decrease AUC(0-3h) of DOB in RMs but increased it in PMs. Omeprazole and lansoprazole at the standard doses inhibit CYP activity but rabeprazole does not, whereas high-dose omeprazole seems to induce CYPs.

  18. Mosapride Accelerates the Delayed Gastric Emptying of High-Viscosity Liquids: A Crossover Study Using Continuous Real-Time 13C Breath Test (BreathID System)

    PubMed Central

    Sakamoto, Yasunari; Sekino, Yusuke; Yamada, Eiji; Ohkubo, Hidenori; Higurashi, Takuma; Sakai, Eiji; Iida, Hiroshi; Hosono, Kunihiro; Endo, Hiroki; Nonaka, Takashi; Ikeda, Tamon; Fujita, Koji; Yoneda, Masato; Koide, Tomoko; Takahashi, Hirokazu; Goto, Ayumu; Abe, Yasunobu; Gotoh, Eiji; Maeda, Shin; Nakajima, Atsushi

    2011-01-01

    Background/Aims The administration of liquid nutrients to patients is often accompanied by complications such as gastroesophageal reflux. To prevent gastroesophageal reflux, high-viscosity liquid meals are used widely, however, it still remains controversial whether high-viscosity liquid meals have any effect on the rate of gastric emptying. The present study was conducted with the aim of determining whether high-viscosity liquid meals had any effect on the rate of gastric emptying and mosapride might accelerate the rate of gastric emptying of high-viscosity liquid meals. Methods Six healthy male volunteers underwent 3 tests at intervals of > 1 week. After fasting for > 8 hours, each subject received one of three test meals (liquid meal only, high-viscosity liquid meal [liquid meal plus pectin] only, or high-viscosity liquid meal 30 minutes after intake of mosapride). A 13C-acetic acid breath test was performed, which monitored the rate of gastric emptying for 4 hours. Using the Oridion Research Software (β version), breath test parameters were calculated. The study parameters were examined for all the 3 test conditions and compared using the Freidman test. Results Gastric emptying was significantly delayed following intake of a high-viscosity liquid meal alone as compared with a liquid meal alone; however, intake of mosapride prior to a high-viscosity liquid meal was associated with a significantly accelerated rate of gastric emptying as compared with a high-viscosity liquid meal alone. Conclusions This study showed that high-viscosity liquid meals delayed gastric emptying: however, mosapride recovered the delayed rate of gastric emptying by high-viscosity liquid meals. PMID:22148109

  19. [*C]octanoic acid breath test to measure gastric emptying rate of solids.

    PubMed

    Maes, B D; Ghoos, Y F; Rutgeerts, P J; Hiele, M I; Geypens, B; Vantrappen, G

    1994-12-01

    We have developed a breath test to measure solid gastric emptying using a standardized scrambled egg test meal (250 kcal) labeled with [14C]octanoic acid or [13C]octanoic acid. In vitro incubation studies showed that octanoic acid is a reliable marker of the solid phase. The breath test was validated in 36 subjects by simultaneous radioscintigraphic and breath test measurements. Nine healthy volunteers were studied after intravenous administration of 200 mg erythromycin and peroral administration of 30 mg propantheline, respectively. Erythromycin significantly enhanced gastric emptying, while propantheline significantly reduced gastric emptying rates. We conclude that the [*C]octanoic breath test is a promising and reliable test for measuring the gastric emptying rate of solids.

  20. Monoclonal Antibody L1Mab-13 Detected Human PD-L1 in Lung Cancers.

    PubMed

    Yamada, Shinji; Itai, Shunsuke; Nakamura, Takuro; Yanaka, Miyuki; Chang, Yao-Wen; Suzuki, Hiroyoshi; Kaneko, Mika K; Kato, Yukinari

    2018-04-01

    Programmed cell death ligand-1 (PD-L1) is a type I transmembrane glycoprotein expressed on antigen-presenting cells. It is also expressed in several tumor cells such as melanoma and lung cancer cells. A strong correlation has been reported between human PD-L1 (hPD-L1) expression in tumor cells and negative prognosis in cancer patients. Here, a novel anti-hPD-L1 monoclonal antibody (mAb) L 1 Mab-13 (IgG 1 , kappa) was produced using a cell-based immunization and screening (CBIS) method. We investigated hPD-L1 expression in lung cancer using flow cytometry, Western blot, and immunohistochemical analyses. L 1 Mab-13 specifically reacted hPD-L1 of hPD-L1-overexpressed Chinese hamster ovary (CHO)-K1 cells and endogenous hPD-L1 of KMST-6 (human fibroblast) in flow cytometry and Western blot. Furthermore, L 1 Mab-13 reacted with lung cancer cell lines (EBC-1, Lu65, and Lu99) in flow cytometry and stained lung cancer tissues in a membrane-staining pattern in immunohistochemical analysis. These results indicate that a novel anti-hPD-L1 mAb, L 1 Mab-13, is very useful for detecting hPD-L1 of lung cancers in flow cytometry, Western blot, and immunohistochemical analyses.

  1. Modified Helicobacter test using a new test meal and a 13C-urea breath test in Helicobacter pylori positive and negative dyspepsia patients on proton pump inhibitors.

    PubMed

    Tepeš, Bojan; Malfertheiner, Peter; Labenz, Joachim; Aygen, Sitke

    2017-08-28

    To determine the sensitivity and specificity of the 13 C-urea breath test (UBT) in patients taking proton pump inhibitors (PPIs), using a new test meal Refex. One hundred and fourteen consecutive patients with dyspepsia, 53 Helicobacter pylori ( H. pylori ) positive, 49 H. pylori negative, were included in the study. The patients were then given esomeprazole 40 mg for 29 consecutive days, and the 13 C-UBT with the new test meal was performed the next morning. The sensitivity of the 13 C-UBT with a cut off 2.5‰ was 92.45% (95%CI: 81.79%-97.91%) by per-protocol (PP) analysis and 78.13% (95%CI: 66.03%-87.49%) by intention-to-treat (ITT) analysis. The specificity of the 13 C-UBT test was 96.00% in the ITT population (95%CI: 86.29%-99.51%) and 97.96% in the PP population (95%CI: 89.15%-99.95%). The new test meal based 13 C-UBT is highly accurate in patients on PPIs and can be used in those unable to stop their PPI treatment.

  2. [Breath tests in children with suspected lactose intolerance].

    PubMed

    Parra, P Ángela; Furió, C Simone; Arancibia, A Gabriel

    2015-01-01

    Up to 70% of the world population is lactose intolerance. However, there are no epidemiological studies among Chilean pediatric population affected by this condition. Clinical characterization of a series of children who underwent the lactose intolerance breath test for lactose intolerance study, establishing intolerance and malabsorption frequencies, the most frequent symptoms, and test performance depending on the origin. Patients under 18 years old who took the lactose intolerance breath test in the Gastroenterology Laboratory of the Catholic University of Chile, and who were admitted due to clinically suspected lactose intolerance. Malabsorption was considered when there was as an increase of ≥20ppm above the baseline (H2) or ≥34ppm of H2 and methane (CH4) combined. Intolerance was considered when the above was associated with a symptom intensity score ≥7 during registration. The analysis included194 patients aged 1 to17 years of age. Of these, 102 (53%) presented with malabsorption, and 53 (27%) were intolerant. The frequency of lactose intolerance varied from 7.1 to 45.4%, and it occurred more frequently at older ages. The most common reported symptoms were abdominal pain, bloating and rumbling. Lactose malabsorption and intolerance can be investigated from the first years of life using the lactose breath test plus a symptom questionnaire. An increase in the frequency of intolerance with age, and a greater number of positive tests, if they were requested by a gastroenterologist, were observed. Copyright © 2015 Sociedad Chilena de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Effect of alcohol consumption on the liver detoxication capacity as measured by [13C]methacetin- and [methyl-13C]methionine-breath tests.

    PubMed

    Wutzke, Klaus D; Forberger, Anke; Wigger, Marianne

    2008-06-01

    The aim of this study was to investigate the hepatic microsomal and mitochondrial functions by using the 13CO2-breath test in healthy subjects either before or after the consumption of red wine. Fourteen adults received [13C]methacetin and [methyl-13C]methionine together with a standardised dinner. Expired air samples were taken over 6 h. After a wash-out period, the subjects consumed 0.4 ml ethanol/kg/day together with dinner over a 10-day period. Thereafter, 13C-tracer administration was repeated under identical conditions. The 13CO2-enrichments were measured by isotope ratio mass spectrometry. The mean cumulative percentage 13C-dose recovery (CPDR) after administration of [13C]methacetin and [methyl-13C]methionine either without or with red wine consumption amounted to 38.2+/-6.3 vs. 36.3+/-6.7% (p=0.363) and 9.5+/-3.3 vs. 8.8+/-2.5% (p=0.47), respectively. Moderate alcohol consumption does not induce significant short-term changes of the microsomal and the mitochondrial functions of the human liver in healthy subjects.

  4. Nutritional status, fecal elastase-1, and 13C-labeled mixed triglyceride breath test in the long-term after pancreaticoduodenectomy.

    PubMed

    Muniz, Cinara Knychala; dos Santos, José Sebastião; Pfrimer, Karina; Ferrioli, Eduardo; Kemp, Rafael; Marchini, Júlio Sérgio; Cunha, Selma Freire

    2014-04-01

    This study aimed to compare the body composition, dietary intake and serum levels of vitamins and minerals, and exocrine pancreatic function in patients late after pancreaticoduodenectomy (PD) and healthy subjects. Fifteen patients (PD group) who had undergone PD over 1 year before the study and 15 health volunteers (control group) were included in the study. All volunteers underwent dietary intake evaluation, body composition, laboratory data, exocrine pancreatic function by elastase-1, and carbon (C )-labeled triglycerides in breath tests. The PD group subjects also underwent upper gastrointestinal endoscopy and small intestinal bacterial overgrowth analysis. Nutrient intake was adequate, and there were no differences in body mass index and mineral serum levels between the groups. The PD group showed lower serum levels of retinol, α-tocopherol, and ascorbic acid. Small intestinal bacterial overgrowth occurred in 39% of the patients. Fecal elastase-1 was lower in the PD group. The PD group had a higher C peak time; the cumulative label C recovery in 7 hours was similar in both groups. Fecal elastase-1 decreased, and the excretion of C in breath was similar to healthy controls. Although the data point toward an adaptation in the absorptive capacity of fats, A, C, and E hypovitaminosis indicate that some absorptive insufficiency persists late after PD.

  5. The Diagnostic Validity of the 13C-Urea Breath Test in the Gastrectomized Patients: Single Tertiary Center Retrospective Cohort Study

    PubMed Central

    Kwon, Yong Hwan; Kim, Nayoung; Lee, Ju Yup; Choi, Yoon Jin; Yoon, Kichul; Yoon, Hyuk; Shin, Cheol Min; Park, Young Soo; Lee, Dong Ho

    2014-01-01

    Background: This study was conducted to evaluate the diagnostic validity of the 13C-urea breath test (13C-UBT) in the remnant stomach after partial gastrectomy for gastric cancer. Methods: The 13C-UBT results after Helicobacter pylori eradication therapy was compared with the results of endoscopic biopsy-based methods in the patients who have received partial gastrectomy for the gastric cancer. Results: Among the gastrectomized patients who showed the positive 13C-UBT results (≥ 2.5‰, n = 47) and negative 13C-UBT results (< 2.5‰, n = 114) after H. pylori eradication, 26 patients (16.1%) and 4 patients (2.5%) were found to show false positive and false negative results based on biopsy-based methods, respectively. The sensitivity, specificity, false positive rate, and false negative rate for the cut-off value of 2.5‰ were 84.0%, 80.9%, 19.1%, and 16.0%, respectively. The positive and negative predictive values were 44.7% and 96.5%, respectively. In the multivariate analysis, two or more H. pylori eradication therapies (odds ratio = 3.248, 95% confidence interval= 1.088–9.695, P = 0.035) was associated with a false positive result of the 13C-UBT. Conclusions: After partial gastrectomy, a discordant result was shown in the positive 13C-UBT results compared to the endoscopic biopsy methods for confirming the H. pylori status after eradication. Additional endoscopic biopsy-based H. pylori tests would be helpful to avoid unnecessary treatment for H. pylori eradication in these cases. PMID:25574466

  6. Drinking influences exhaled breath condensate acidity.

    PubMed

    Kullmann, Tamás; Barta, Imre; Antus, Balázs; Horváth, Ildikó

    2008-01-01

    Exhaled breath condensate analysis is a developing method for investigating airway pathology. Impact of food and drink on breath condensate composition has not been systematically addressed. The aim of the study was to follow exhaled breath condensate pH after drinking an acidic and a neutral beverage. Breath condensate, capillary blood, and urine of 12 healthy volunteers were collected before and after drinking either 1 l of coke or 1 l of mineral water. The pH of each sample was determined with a blood gas analyzer. The mean difference between the pH of two breath condensate samples collected within 15 min before drinking was 0.13+/-0.03. Condensate pH decreased significantly from 6.29+/-0.02 to 6.24+/-0.02 (p<0.03) after drinking coke and from 6.37+/-0.03 to 6.22+/-0.04 (p<0.003) after drinking water. Drinking coke induced significant changes in blood and urine pH as well. Drinking influences exhaled breath condensate composition and may contribute to the variability of exhaled breath condensate pH.

  7. 42 CFR 84.88 - Breathing bag test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Breathing bag test. 84.88 Section 84.88 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing...

  8. 42 CFR 84.88 - Breathing bag test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Breathing bag test. 84.88 Section 84.88 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing...

  9. 42 CFR 84.88 - Breathing bag test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Breathing bag test. 84.88 Section 84.88 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing...

  10. 42 CFR 84.88 - Breathing bag test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Breathing bag test. 84.88 Section 84.88 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing...

  11. Oral and intravenous l-[1-13 C]phenylalanine delivery measure similar rates of elimination when gastric emptying and splanchnic extraction are accounted for in adult mixed hounds.

    PubMed

    Gooding, M A; Cant, J P; Pencharz, P B; Davenport, G M; Atkinson, J L; Shoveller, A K

    2013-02-01

    There are few reported estimates of amino acid (AA) kinetics in adult mammals and none exist in adult dogs. The study objectives were to evaluate the use of oral isotope delivery in contrast to the more commonly used intravenous (IV) delivery to estimate AA kinetics in adult dogs and to estimate splanchnic extraction and gastric emptying using a commonly accepted mathematical model. Dogs received 25 × 1/2-hourly meals (13 g/kg BW/day) and either an oral or IV bolus of l-[1-(13) C]Phe (12 mg/kg BW). Blood samples were taken immediately before each feeding. Concentrations of plasma Phe were measured using liquid chromatography-tandem mass spectrometry. There were no differences in baseline plasma Phe concentrations (34 μm ± 0.61), Phe distribution volume, Phe pool size and rate constants between dogs when the tracer was administered IV or orally (p > 0.25). Decay curve for plasma l-[1-(13) C]Phe differed between IV and oral dosing protocols with IV dosing fit best using a two-compartment model. Phe disappeared from plasma at a mean rate of 2.8%/min. Estimates of gastric emptying and splanchnic extraction did not differ based on oral or IV tracer dosing when the decay curves were fit with the two-compartment model (p > 0.40). The half-life for gastric emptying was 18 min, and first-pass Phe extraction by the splanchnic bed was 24% of the dietary Phe. These results suggest that oral isotope dosing can be used as an alternative to IV isotope dosing in studies that utilize a primed, constant dosing approach to measure protein and amino acid kinetics. © 2011 Blackwell Verlag GmbH.

  12. A Modified Carbon Monoxide Breath Test for Measuring Erythrocyte Lifespan in Small Animals

    PubMed Central

    Ma, Yong-Jian; Zhang, Hou-De; Ji, Yong-Qiang; Zhu, Guo-Liang; Huang, Jia-Liang; Du, Li-Tao; Cao, Ping; Zang, De-Yue; Du, Ji-Hui; Li, Rong; Wang, Lei

    2016-01-01

    This study was to develop a CO breath test for RBC lifespan estimation of small animals. The ribavirin induced hemolysis rabbit models were placed individually in a closed rebreath cage and air samples were collected for measurement of CO concentration. RBC lifespan was calculated from accumulated CO, blood volume, and hemoglobin concentration data. RBC lifespan was determined in the same animals with the standard biotin-labeling method. RBC lifespan data obtained by the CO breath test method for control (CON, 49.0 ± 5.9 d) rabbits, rabbits given 10 mg/kg·d−1 of ribavirin (RIB10, 31.0 ± 4.0 d), and rabbits given 20 mg/kg·d−1 of ribavirin (RIB20, 25.0 ± 2.9 d) were statistically similar (all p > 0.05) to and linearly correlated (r = 0.96, p < 0.01) with the RBC lifespan data obtained for the same rabbits by the standard biotin-labeling method (CON, 51.0 ± 2.7 d; RIB10, 33.0 ± 1.3 d; and RIB20, 27.0 ± 0.8 d). The CO breath test method takes less than 3 h to complete, whereas the standard method requires at least several weeks. In conclusion, the CO breath test method provides a simple and rapid means of estimating RBC lifespan and is feasible for use with small animal models. PMID:27294128

  13. Can handling E85 motor fuel cause positive breath alcohol test results?

    PubMed

    Ran, Ran; Mullins, Michael E

    2013-09-01

    Hand-held breath alcohol analyzers are widely used by police in traffic stops of drivers suspected of driving while intoxicated (DWI). E85 is a motor fuel consisting of 85% ethanol and 15% gasoline or other hydrocarbons, and is available at nearly 2,600 stations in the USA. We sought to determine whether handling E85 fuel could produce measurable breath alcohol results using a hand-held analyzer and to see if this would be a plausible explanation for a positive breath alcohol test. Five healthy adult subjects dispensed or transferred 8 US gallons of E85 fuel in each of four scenarios. We measured breath alcohol concentration in g/210 L of exhaled breath using the BACTrack S50 at 0, 2, 4, 6, 8, 10, 15 and 20 min after each fuel-handling scenario. Most of the subjects had no detectable breath alcohol after handling E85 motor fuel. Transient elevations (0.02-0.04 g/210 L) in breath alcohol measurement occurred up to 6 min after handling E85 in a minority of subjects. We conclude that it is unlikely that handling E85 motor fuel would result in erroneous prosecution for DWI.

  14. Cut-off optimization for 13C-urea breath test in a community-based trial by mathematic, histology and serology approach.

    PubMed

    Li, Zhe-Xuan; Huang, Lei-Lei; Liu, Cong; Formichella, Luca; Zhang, Yang; Wang, Yu-Mei; Zhang, Lian; Ma, Jun-Ling; Liu, Wei-Dong; Ulm, Kurt; Wang, Jian-Xi; Zhang, Lei; Bajbouj, Monther; Li, Ming; Vieth, Michael; Quante, Michael; Zhou, Tong; Wang, Le-Hua; Suchanek, Stepan; Soutschek, Erwin; Schmid, Roland; Classen, Meinhard; You, Wei-Cheng; Gerhard, Markus; Pan, Kai-Feng

    2017-05-18

    The performance of diagnostic tests in intervention trials of Helicobacter pylori (H.pylori) eradication is crucial, since even minor inaccuracies can have major impact. To determine the cut-off point for 13 C-urea breath test ( 13 C-UBT) and to assess if it can be further optimized by serologic testing, mathematic modeling, histopathology and serologic validation were applied. A finite mixture model (FMM) was developed in 21,857 subjects, and an independent validation by modified Giemsa staining was conducted in 300 selected subjects. H.pylori status was determined using recomLine H.pylori assay in 2,113 subjects with a borderline 13 C-UBT results. The delta over baseline-value (DOB) of 3.8 was an optimal cut-off point by a FMM in modelling dataset, which was further validated as the most appropriate cut-off point by Giemsa staining (sensitivity = 94.53%, specificity = 92.93%). In the borderline population, 1,468 subjects were determined as H.pylori positive by recomLine (69.5%). A significant correlation between the number of positive H.pylori serum responses and DOB value was found (r s  = 0.217, P < 0.001). A mathematical approach such as FMM might be an alternative measure in optimizing the cut-off point for 13 C-UBT in community-based studies, and a second method to determine H.pylori status for subjects with borderline value of 13 C-UBT was necessary and recommended.

  15. Neuromuscular electrical stimulation prior to presleep protein feeding stimulates the use of protein-derived amino acids for overnight muscle protein synthesis.

    PubMed

    Dirks, Marlou L; Groen, Bart B L; Franssen, Rinske; van Kranenburg, Janneau; van Loon, Luc J C

    2017-01-01

    Short periods of muscle disuse result in substantial skeletal muscle atrophy. Recently, we showed that both neuromuscular electrical stimulation (NMES) as well as presleep dietary protein ingestion represent effective strategies to stimulate muscle protein synthesis rates. In this study, we test our hypothesis that NMES can augment the use of presleep protein-derived amino acids for overnight muscle protein synthesis in older men. Twenty healthy, older [69 ± 1 (SE) yr] men were subjected to 24 h of bed rest, starting at 8:00 AM. In the evening, volunteers were subjected to 70-min 1-legged NMES, while the other leg served as nonstimulated control (CON). Immediately following NMES, 40 g of intrinsically l-[1- 13 C]-phenylalanine labeled protein was ingested prior to sleep. Blood samples were taken throughout the night, and muscle biopsies were obtained from both legs in the evening and the following morning (8 h after protein ingestion) to assess dietary protein-derived l-[1- 13 C]-phenylalanine enrichments in myofibrillar protein. Plasma phenylalanine concentrations and plasma l-[1- 13 C]-phenylalanine enrichments increased significantly following protein ingestion and remained elevated for up to 6 h after protein ingestion (P < 0.05). During overnight sleep, myofibrillar protein-bound l-[1- 13 C]-phenylalanine enrichments (MPE) increased to a greater extent in the stimulated compared with the control leg (0.0344 ± 0.0019 vs. 0.0297 ± 0.0016 MPE, respectively; P < 0.01), representing 18 ± 6% greater incorporation of presleep protein-derived amino acids in the NMES compared with CON leg. In conclusion, application of NMES prior to presleep protein feeding stimulates the use of dietary protein-derived amino acids for overnight muscle protein synthesis in older men. Neuromuscular electrical stimulation (NMES) as well as presleep dietary protein ingestion represent effective strategies to stimulate muscle protein synthesis rates. Here we demonstrate that in older

  16. Clinical applications of breath testing

    PubMed Central

    Paschke, Kelly M; Mashir, Alquam

    2010-01-01

    Breath testing has the potential to benefit the medical field as a cost-effective, non-invasive diagnostic tool for diseases of the lung and beyond. With growing evidence of clinical worth, standardization of methods, and new sensor and detection technologies the stage is set for breath testing to gain considerable attention and wider application in upcoming years. PMID:21173863

  17. 21 CFR 862.3050 - Breath-alcohol test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Breath-alcohol test system. 862.3050 Section 862....3050 Breath-alcohol test system. (a) Identification. A breath-alcohol test system is a device intened to measure alcohol in the human breath. Measurements obtained by this device are used in the...

  18. 21 CFR 862.3050 - Breath-alcohol test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Breath-alcohol test system. 862.3050 Section 862....3050 Breath-alcohol test system. (a) Identification. A breath-alcohol test system is a device intened to measure alcohol in the human breath. Measurements obtained by this device are used in the...

  19. The characterisation of hepatic mitochondrial function in patients with non-alcoholic fatty liver disease (NAFLD) using the 13C-ketoisocaproate breath test.

    PubMed

    Afolabi, Paul R; Scorletti, Eleonora; Smith, Debbie E; Almehmadi, Amal A; Calder, Philip C; Byrne, Christopher D

    2018-06-26

    Hepatic mitochondrial function (HMF) assessed by the <sup>13</sup>C-ketoisocaproate breath test (<sup>13</sup>C-KICA BT) has been previously shown to be significantly associated with the severity of biopsy proven non-alcoholic fatty liver disease (NAFLD). However, it is uncertain whether any perturbation in HMF relates specifically to severity of liver disease or factors associated with metabolic syndrome within non-alcoholic fatty liver disease (NAFLD). Our aim was to investigate whether there was any change in HMF assessed by <sup>13</sup>C-KICA BT in patients with NAFLD compared to control subjects, and to assess the factors that are independently associated with HMF. 77 patients with NAFLD and 11 healthy control subjects were studied. HMF was assessed using <sup>13</sup>C-KICA BT and expressed as cumulative % <sup>13</sup>C-dose recovered on breath over 1hr (cPDR over 1hr). Liver fat and fibrosis was assessed by transient elastography. Multi-variable linear regression modelling was undertaken to test the independence of associations with HMF. HMF (cPDR over 1hr) was lower in NAFLD compared to controls [13.4% (4.8) v. 21.0% (6.3); p< 0.0001)]. In NAFLD, HMF was lower in patients with diabetes versus no diabetes [12.7% (3.4) v. 14.3% (6.1); p=0.003)]. Regression modelling showed age (β= -0.08; p=0.01), waist circumference (β= -0.08; p=0.01), hip circumference (β= -0.04; p=0.01), aspartate aminotransferase (AST) (β= -0.05; p=0.01) and diabetes status (β= -1.81; p=0.01) were independently associated with HMF (R<sup>2</sup>= 41.5%; p<0.0001). In patients with NAFLD (compared to healthy subjects), there was a reduction in HMF assessed by the <sup>13</sup>C-KICA BT. Furthermore, in patients with NAFLD, HMF is independent and inversely associated with age, waist and hip circumference, AST and diabetes status. © 2018 IOP Publishing Ltd.

  20. Breath condenser coatings affect measurement of biomarkers in exhaled breath condensate.

    PubMed

    Rosias, P P; Robroeks, C M; Niemarkt, H J; Kester, A D; Vernooy, J H; Suykerbuyk, J; Teunissen, J; Heynens, J; Hendriks, H J; Jöbsis, Q; Dompeling, E

    2006-11-01

    Exhaled breath condensate collection is not yet standardised and biomarker measurements are often close to lower detection limits. In the current study, it was hypothesised that adhesive properties of different condenser coatings interfere with measurements of eicosanoids and proteins in breath condensate. In vitro, condensate was derived from a collection model using two test solutions (8-isoprostane and albumin) and five condenser coatings (silicone, glass, aluminium, polypropylene and Teflon). In vivo, condensate was collected using these five coatings and the EcoScreen condenser to measure 8-isoprostane, and three coatings (silicone, glass, EcoScreen) to measure albumin. In vitro, silicone and glass coatings had significantly higher albumin recovery compared with the other coatings. A similar trend was observed for 8-isoprostane recovery. In vivo, median (interquartile range) 8-isoprostane concentrations were significantly higher using silicone (9.2 (18.8) pg.mL(-1)) or glass (3.0 (4.5) pg.mL(-1)) coating, compared with aluminium (0.5 (2.4) pg.mL(-1)), polypropylene (0.5 (0.5) pg.mL(-1)), Teflon (0.5 (0.0) pg.mL(-1)), and EcoScreen (0.5 (2.0) pg.mL(-1)). Albumin in vivo was mainly detectable using glass coating. In conclusion, a condenser with silicone or glass coating is more efficient for measurement of 8-isoprostane or albumin in exhaled breath condensate, than EcoScreen, aluminium, polypropylene or Teflon. Guidelines for exhaled breath condensate standardisation should include the most valid condenser coating to measure a specific biomarker.

  1. The Diagnostic Validity of Citric Acid-Free, High Dose (13)C-Urea Breath Test After Helicobacter pylori Eradication in Korea.

    PubMed

    Kwon, Yong Hwan; Kim, Nayoung; Lee, Ju Yup; Choi, Yoon Jin; Yoon, Kichul; Hwang, Jae Jin; Lee, Hyun Joo; Lee, AeRa; Jeong, Yeon Sang; Oh, Sooyeon; Yoon, Hyuk; Shin, Cheol Min; Park, Young Soo; Lee, Dong Ho

    2015-06-01

    The (13)C-urea breath test ((13)C-UBT) is a noninvasive method for diagnosing Helicobacter pylori (H. pylori) infection. The aims of this study were to evaluate the diagnostic validity of the (13)C-UBT cutoff value and to identify influencing clinical factors responsible for aberrant results. (13)C-UBT (UBiTkit; Otsuka Pharmaceutical, cutoff value: 2.5‰) results in the range 2.0‰ to 10.0‰ after H. pylori eradication therapy were compared with the results of endoscopic biopsy results of the antrum and body. Factors considered to affect test results adversely were analyzed. Among patients with a positive (13)C-UBT result (2.5‰ to 10.0‰, n = 223) or a negative (13)C-UBT result (2.0‰ to < 2.5‰, n = 66) after H. pylori eradication, 73 patients (34.0%) were false positive, and one (1.5%) was false negative as determined by endoscopic biopsy. The sensitivity, specificity, false-positive rate, and false-negative rate for a cutoff value of 2.5‰ were 99.3%, 47.1%, 52.9%, and 0.7%, respectively, and positive and negative predictive values of the (13)C-UBT were 67.3% and 98.5%, respectively. Multivariate analysis showed that a history of two or more previous H. pylori eradication therapies (OR = 2.455, 95%CI = 1.299-4.641) and moderate to severe gastric intestinal metaplasia (OR = 3.359, 95%CI = 1.572-7.178) were associated with a false-positive (13)C-UBT result. The (13)C-UBT cutoff value currently used has poor specificity for confirming H. pylori status after eradication, and this lack of specificity is exacerbated in patients that have undergone multiple prior eradication therapies and in patients with moderate to severe gastric intestinal metaplasia. In addition, the citric-free (13)C-UBT would increase a false-positive (13)C-UBT result. © 2015 John Wiley & Sons Ltd.

  2. 26 CFR 36.3121(l)(1)-3 - Effect of agreement.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 15 2010-04-01 2010-04-01 false Effect of agreement. 36.3121(l)(1)-3 Section 36.3121(l)(1)-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED... SUBSIDIARIES § 36.3121(l)(1)-3 Effect of agreement. (a) Liability for amounts equivalent to tax—(1) In general...

  3. Can Handling E85 Motor Fuel Cause Positive Breath Alcohol Test Results?

    PubMed Central

    Ran, Ran; Mullins, Michael E.

    2013-01-01

    Hand-held breath alcohol analyzers are widely used by police in traffic stops of drivers suspected of driving while intoxicated (DWI). E85 is a motor fuel consisting of 85% ethanol and 15% gasoline or other hydrocarbons, and is available at nearly 2,600 stations in the USA. We sought to determine whether handling E85 fuel could produce measurable breath alcohol results using a hand-held analyzer and to see if this would be a plausible explanation for a positive breath alcohol test. Five healthy adult subjects dispensed or transferred 8 US gallons of E85 fuel in each of four scenarios. We measured breath alcohol concentration in g/210 L of exhaled breath using the BACTrack S50 at 0, 2, 4, 6, 8, 10, 15 and 20 min after each fuel-handling scenario. Most of the subjects had no detectable breath alcohol after handling E85 motor fuel. Transient elevations (0.02–0.04 g/210 L) in breath alcohol measurement occurred up to 6 min after handling E85 in a minority of subjects. We conclude that it is unlikely that handling E85 motor fuel would result in erroneous prosecution for DWI. PMID:23843422

  4. Breath tests sustainability in hospital settings: cost analysis and reimbursement in the Italian National Health System.

    PubMed

    Volpe, M; Scaldaferri, F; Ojetti, V; Poscia, A

    2013-01-01

    The high demand of Breath Tests (BT) in many gastroenterological conditions in time of limited resources for health care systems, generates increased interest in cost analysis from the point of view of the delivery of services to better understand how use the money to generate value. This study aims to measure the cost of C13 Urea and other most utilized breath tests in order to describe key aspects of costs and reimbursements looking at the economic sustainability for the hospital. A hospital based cost-analysis of the main breath tests commonly delivery in an ambulatory setting is performed. Mean salary for professional nurses and gastroenterologists, drugs/preparation used and disposable materials, purchase and depreciation of the instrument and the testing time was used to estimate the cost, while reimbursements are based on the 2013 Italian National Health System ambulatory pricelist. Variables that could influence the model are considered in the sensitivity analyses. The mean cost for C13--Urea, Lactulose and Lactose BT are, respectively, Euros 30,59; 45,20 and 30,29. National reimbursement often doesn't cover the cost of the analysis, especially considering the scenario with lower number of exam. On the contrary, in high performance scenario all the reimbursement could cover the cost, except for the C13 Urea BT that is high influenced by the drugs cost. However, consideration about the difference between Italian Regional Health System ambulatory pricelist are done. Our analysis shows that while national reimbursement rates cover the costs of H2 breath testing, they do not cover sufficiently C13 BT, particularly urea breath test. The real economic strength of these non invasive tests should be considered in the overall organization of inpatient and outpatient clinic, accounting for complete diagnostic pathway for each gastrointestinal disease.

  5. Screening of exhaled breath by low-resolution multicomponent FT-IR spectrometry in patients attending emergency departments.

    PubMed

    Laakso, Olli; Haapala, Matti; Kuitunen, Tapio; Himberg, Jaakko-Juhani

    2004-03-01

    Interest in noninvasive methods for disease diagnosis is increasing. In this study, we tested the utility and potential of a portable Fourier transform infrared (FT-IR) multicomponent analyzer in the emergency rooms (ERs) of two Finnish hospitals. Major detected breath volatiles in this population were ethanol, carbon monoxide, methane, and acetone, in addition to carbon dioxide and water. The analysis of breath revealed an ethanol concentration of over 25 ppm (0.1 g/L in blood) in 56 out of 589 patients (9.5%). During nightshifts the proportion was 30% for all and 63% for trauma patients. Five-hundred eighty-four patients had measurable carbon monoxide in their breath. A breath carbon monoxide of over 4 ppm (4.4 micro g/L) differentiated smokers from nonsmokers. Methane over 2 ppm (1.3 micro g/L) was detected in the breath of 32% of the participants. Methane concentration was higher among aged patients. Two-hundred ninety-eight participants had detectable acetone in their breath. Elevated exhaled acetone [10-76 ppm (23-75 micro g/L)] was detected in 10 patients. The FT-IR method proved functional in the ER setting. A major advantage over blood sampling was fast and easy analysis performed by nonlaboratory personnel.

  6. Comparison of 72-hour fecal fat quantification and the 13C-mixed triglyceride breath test in assessing pancreatic exocrine sufficiency in children with chronic pancreatitis.

    PubMed

    Wejnarska, Karolina; Kołodziejczyk, Elwira; Ryżko, Józef; Oracz, Grzegorz

    Chronic pancreatitis (CP) in children is still a rare, although increasingly recognized entity. Over the duration of the disease several complications can be observed, two of which are major ones: endo- and exocrine insufficiency. In the medical care of children with CP it is crucial to diagnose the decreased endo- and exocrine function of the pancreas, in order to preserve patients from malnutrition and the failure to thrive. The aim of the study was to compare the usefulness of two indirect methods of assessing the pancreas exocrine function in children with CP. Ninety one patients with CP were enrolled in the study (41 boys, 50 girls, aged 2-17.8 years). Only Patients who had had both the 72-hour fecal fat quantification and the 13C-mixed triglyceride breath test (13C -MTBT) performed were selected. We compared the results of both tests for sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) in detecting exocrine pancreatic insufficiency. Out of 91 patients, 12 were diagnosed with exocrine pancreatic insufficiency (EPI). The sensitivity of the fecal fat quantification was 50%, the specificity for the test was 100%. PPV and NPV were 100% and 93%, respectively. 13C-MTBT had the sensitivity of 42% and the specificity of 99%. PPV and NPV for the breath test were of 83% and 92%, respectively. No statistically significant discrepancy between the values obtained was found. Although the 72-hour fecal fat quantification remains the gold standard in detecting EPI, both of the methods that had been investigated were shown to be comparable regarding sensitivity, specificity, PPV and NPV in assessing pancreas exocrine sufficiency in children with CP. Due to the easier execution of the breath test, both for the patient and for medical personnel, its importance may increase.

  7. Assessment of gastric emptying in non-obese diabetic mice using a [13C]-octanoic acid breath test.

    PubMed

    Creedon, Christopher T; Verhulst, Pieter-Jan; Choi, Kyoung M; Mason, Jessica E; Linden, David R; Szurszewski, Joseph H; Gibbons, Simon J; Farrugia, Gianrico

    2013-03-23

    Gastric emptying studies in mice have been limited by the inability to follow gastric emptying changes in the same animal since the most commonly used techniques require killing of the animals and postmortem recovery of the meal(1,2). This approach prevents longitudinal studies to determine changes in gastric emptying with age and progression of disease. The commonly used [(13)C]-octanoic acid breath test for humans(3) has been modified for use in mice(4-6) and rats(7) and we previously showed that this test is reliable and responsive to changes in gastric emptying in response to drugs and during diabetic disease progression(8). In this video presentation the principle and practical implementation of this modified test is explained. As in the previous study, NOD LtJ mice are used, a model of type 1 diabetes(9). A proportion of these mice develop the symptoms of gastroparesis, a complication of diabetes characterized by delayed gastric emptying without mechanical obstruction of the stomach(10). This paper demonstrates how to train the mice for testing, how to prepare the test meal and obtain 4 hr gastric emptying data and how to analyze the obtained data. The carbon isotope analyzer used in the present study is suitable for the automatic sampling of the air samples from up to 12 mice at the same time. This technique allows the longitudinal follow-up of gastric emptying from larger groups of mice with diabetes or other long-standing diseases.

  8. 13C-Labeled-Starch Breath Test in Congenital Sucrase-isomaltase Deficiency.

    PubMed

    Robayo-Torres, Claudia C; Diaz-Sotomayor, Marisela; Hamaker, Bruce R; Baker, Susan S; Chumpitazi, Bruno P; Opekun, Antone R; Nichols, Buford L

    2018-06-01

    Human starch digestion is a multienzyme process involving 6 different enzymes: salivary and pancreatic α-amylase; sucrase and isomaltase (from sucrose-isomaltase [SI]), and maltase and glucoamylase (from maltase-glucoamylase [MGAM]). Together these enzymes cleave starch to smaller molecules ultimately resulting in the absorbable monosaccharide glucose. Approximately 80% of all mucosal maltase activity is accounted for by SI and the reminder by MGAM. Clinical studies suggest that starch may be poorly digested in those with congenital sucrase-isomaltase deficiency (CSID). Poor starch digestion occurs in individuals with CSID and can be documented using a noninvasive C-breath test (BT). C-Labled starch was used as a test BT substrate in children with CSID. Sucrase deficiency was previously documented in study subjects by both duodenal biopsy enzyme assays and C-sucrose BT. Breath CO2 was quantitated at intervals before and after serial C-substrate loads (glucose followed 75 minutes later by starch). Variations in metabolism were normalized against C-glucose BT (coefficient of glucose absorption). Control subjects consisted of healthy family members and a group of children with functional abdominal pain with biopsy-proven sucrase sufficiency. Children with CSID had a significant reduction of C-starch digestion mirroring that of their duodenal sucrase and maltase activity and C-sucrase BT. In children with CSID, starch digestion may be impaired. In children with CSID, starch digestion correlates well with measures of sucrase activity.

  9. Laboratory testing of two prototype in-vehicle breath test devices

    DOT National Transportation Integrated Search

    1985-08-01

    This report presents the results of laboratory testing of two recently developed prototype in-vehicle breath test devices. These devices are designed to prevent persons with alcohol on their breath from driving a car. The devices tested were the SOBE...

  10. Effect of DA-9701 on gastric emptying in a mouse model: assessment by ¹³C-octanoic acid breath test.

    PubMed

    Lim, Chul-Hyun; Choi, Myung-Gyu; Park, Hyeyeon; Baeg, Myong Ki; Park, Jae Myung

    2013-07-21

    To evaluate the effects of DA-9701 on the gastric emptying of a solid meal using the ¹³C-octanoic acid breath test in a mouse model. Male C57BL/6 mice aged > 8 wk and with body weights of 20-25 g were used in this study. The solid test meal consisted of 200 mg of egg yolk labeled with 1.5 L/g ¹³C-octanoic acid. The mice were placed in a 130 mL chamber flushed with air at a flow speed of 200 mL/min. Breath samples were collected for 6 h. The half-emptying time and lag phase were calculated using a modified power exponential model. To assess the reproducibility of the ¹³C-octanoic acid breath test, the breath test was performed two times at intervals of one week in ten mice without drug treatment. To assess the gastrokinetic effects of DA-9701, the breath test was performed three times in another twelve mice, with a randomized crossover sequence of three drug treatments: DA-9701 3 mg/kg, erythromycin 6 mg/kg, or saline. Each breath test was performed at an interval of one week. Repeatedly measured half gastric emptying time of ten mice without drug treatment showed 0.856 of the intraclass correlation coefficient for the half gastric emptying time (P = 0.004). The mean cumulative excretion curve for the ¹³C-octanoic acid breath test showed accelerated gastric emptying after DA-9701 treatment compared with the saline control (P = 0.028). The median half gastric emptying time after the DA-9701 treatment was significantly shorter than after the saline treatment [122.4 min (109.0-137.9 min) vs 134.5 min (128.4-167.0 min), respectively; P = 0.028] and similar to that after the erythromycin treatment [123.3 min (112.9-138.2 min)]. The lag phase, which was defined as the period taken to empty 15% of a meal, was significantly shorter after the DA-9701 treatment than after the saline treatment [48.1 min (44.6-57.1 min) vs 52.6 min (49.45-57.4 min), respectively; P = 0.049]. The novel prokinetic agent DA-9701 accelerated gastric emptying, assessed with repeated

  11. Significance of hydrogen breath tests in children with suspected carbohydrate malabsorption

    PubMed Central

    2014-01-01

    Background Hydrogen breath tests are noninvasive procedures frequently applied in the diagnostic workup of functional gastrointestinal disorders. Here, we review hydrogen breath test results and the occurrence of lactose, fructose and sorbitol malabsorption in pediatric patients; and determine the significance of the findings and the outcome of patients with carbohydrate malabsorption. Methods We included 206 children (88 male, 118 female, median age 10.7 years, range 3–18 years) with a total of 449 hydrogen breath tests (lactose, n = 161; fructose, n = 142; sorbitol, n = 146) into a retrospective analysis. Apart from test results, we documented symptoms, the therapeutic consequences of the test, the outcome and the overall satisfaction of the patients and families. Results In total, 204 (46%) of all breath tests were positive. Long-term follow-up data could be collected from 118 patients. Of 79 patients (67%) who were put on a diet reduced in lactose, fructose and/or sorbitol, the majority (92%, n = 73) reported the diet to be strict and only 13% (n = 10) had no response to diet. Most families (96%, n = 113) were satisfied by the test and the therapy. There were only 21 tests (5%) with a borderline result because the criteria for a positive result were only partially met. Conclusions Hydrogen breath tests can be helpful in the evaluation of children with gastrointestinal symptoms including functional intestinal disorders. If applied for a variety of carbohydrates but only where indicated, around two-third of all children have positive results. The therapeutic consequences are successfully relieving symptoms in the vast majority of patients. PMID:24575947

  12. 46 CFR 197.450 - Breathing gas tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Breathing gas tests. 197.450 Section 197.450 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE OCCUPATIONAL SAFETY AND HEALTH STANDARDS GENERAL PROVISIONS Commercial Diving Operations Periodic Tests and Inspections of Diving Equipment § 197.450 Breathing gas tests. The diving...

  13. A rapid non invasive L-DOPA-¹³C breath test for optimally suppressing extracerebral AADC enzyme activity - toward individualizing carbidopa therapy in Parkinson’s disease.

    PubMed

    Modak, Anil; Durso, Raymon; Josephs, Ephraim; Rosen, David

    2012-01-01

    Peripheral carbidopa (CD) levels directly impact on central dopamine (DA) production in Parkinson disease (PD) through extracerebral inhibition of dopa decarboxylase (AADC) resulting in an increase in levodopa (LD) bioavailability. Recent data suggests that higher CD doses than those presently used in PD treatment may result in improved clinical response. Optimizing CD doses in individual patients may, therefore, result in ideal individualized treatment. A single center, randomized, double-blind study was carried out recruiting 5 Parkinson’s disease (PD) patients already on LD/CD and 1 treatment näve PD patient using stable isotope labeled LD-1-¹³C as a substrate for a noninvasive breath test to evaluate individual AADC enzyme activity. Each patient was studied five times, receiving 200 mg LD-¹³C at each visit along with one of five randomized CD doses (0, 25, 50, 100 and 200 mg). The metabolite ¹³CO₂ in breath was measured for evaluating AADC enzyme activity and plasma metabolite levels for LD-¹³C and homovanillic acid (HVA) were measured for 4 hours. HVA in plasma and ¹³CO₂ in breath are metabolic products of LD. We found a significant positive correlation of ¹³CO₂ DOB AUC0-240 with serum HVA AUC0-240 following the oral dose of LD-1-¹³C for all 5 doses of CD (r² = 0.9378). With increasing inhibition of AADC enzyme activity with CD, we observed an increase in the plasma concentration of LD.We found an inverse correlation of the 13CO2 DOB AUC with serum LD-¹³C AUC. Our studies indicate the optimal dose of CD for maximal suppression of AADC enzyme activity can be determined for each individual from ¹³CO₂ generation in breath. The LD-breath test can be a useful noninvasive diagnostic tool for evaluation of AADC enzyme activity using the biomarker ¹³CO₂ in breath, a first step in personalizing CD doses for PD patients.

  14. 13C Methacetin Breath Test for Assessment of Microsomal Liver Function: Methodology and Clinical Application.

    PubMed

    Gorowska-Kowolik, Katarzyna; Chobot, Agata; Kwiecien, Jaroslaw

    2017-01-01

    Assessment of the liver function, and the need of constant monitoring of the organ's capacity, concerns not only patients with primary liver diseases, but also those at risk of hepatopathies secondary to other chronic diseases. Most commonly, the diagnostics is based on measurements of static biochemical parameters, which allow us to draw conclusions only indirectly about the function and the degree of damage of the organ. On the other hand, liver biopsy is an invasive procedure and therefore it is associated with a considerable risk of complications. Dynamic tests enable us to assess quantitatively the organ's functional reserve by analyzing the kinetics of the metabolization of the substrate by the liver. In practice applied are breath tests using substances such as aminopyrine, caffeine, methacetin, erythromycin (for assessment of the microsomal function); phenylalanine, galactose (for assessment of the cytosolic function); methionine, octanoate, ketoisocaproic acid (for assessment of the mitochondrial function). The test with 13 C methacetin belongs to the best described and most widely applied methods in noninvasive liver function assessment. Due to the rising availability of this method, knowledge concerning its limitations and controversies regarding the methodology, as well as its usefulness in chosen groups of patients, seems to be vital.

  15. Photoacoustic sensor for VOCs: first step towards a lung cancer breath test

    NASA Astrophysics Data System (ADS)

    Wolff, Marcus; Groninga, Hinrich G.; Dressler, Matthias; Harde, Hermann

    2005-08-01

    Development of new optical sensor technologies has a major impact on the progression of diagnostic methods. Specifically, the optical analysis of breath is an extraordinarily promising technique. Spectroscopic sensors for the non-invasive 13C-breath tests (the Urea Breath Test for detection of Helicobacter pylori is most prominent) are meanwhile well established. However, recent research and development go beyond gastroenterological applications. Sensitive and selective detection of certain volatile organic compounds (VOCs) in a patient's breath, could enable the diagnosis of diseases that are very difficult to diagnose with contemporary techniques. For instance, an appropriate VOC biomarker for early-stage bronchial carcinoma (lung cancer) is n-butane (C4H10). We present a new optical detection scheme for VOCs that employs an especially compact and simple set-up based on photoacoustic spectroscopy (PAS). This method makes use of the transformation of absorbed modulated radiation into a sound wave. Employing a wavelength-modulated distributed feedback (DFB) diode laser and taking advantage of acoustical resonances of the sample cell, we performed very sensitive and selective measurements on butane. A detection limit for butane in air in the ppb range was achieved. In subsequent research the sensitivity will be successively improved to match the requirements of the medical application. Upon optimization, our photoacoustic sensor has the potential to enable future breath tests for early-stage lung cancer diagnostics.

  16. Evaluation of a portable evidential breath alcohol analyzer.

    PubMed

    Razatos, Gerasimos; Luthi, Ruth; Kerrigan, Sarah

    2005-10-04

    The Scientific Laboratory Division (SLD) of the Department of Health acts by mandate as the regulatory agency for the Implied Consent Program for the State of New Mexico. The Laboratory is responsible for all blood and breath alcohol testing activities for law enforcement statewide. The geographical size and the nature of the state, characterized by a highly rural population, demands portable breath alcohol testing equipment. Moreover, future expansion and success of the breath-testing program has focused on instrument portability and data management as critical issues amongst law enforcement agencies and the courts. Thus, the Implied Consent Section of the SLD evaluated the performance of the Intoxilyzer 8000, a portable instrument, against the Intoxilyzer 5000, a stationary instrument, which is currently approved for use. Instrument performance was evaluated at various ethanol concentrations, ranging from 0.04 to 0.55 g/100mL in blood or g/210 L breath. Special attention was placed on instrument performance at the per se and aggravated DWI levels of 0.08 g/100mL and 0.16 g/dL, respectively, due to their legal significance. Precision and accuracy were evaluated using in-house ethanol controls in a wet bath simulator. Coefficients of variation using the Intoxilyzer 8000 ranged from 0.30 to 1.3% (n=102), while CVs for the Intoxilyzer 5000 were 0.7-2.1% (n=102). Calibration stability was assessed in addition to the distribution of data at concentrations between 0.04 and 0.55 g/210 L. Accuracy was 100-102% for the Intoxilyzer 5000 and 99-101% using the Intoxilyzer 8000. Linear regression analysis of more than 700 comparative measurements revealed an R(2) of 1.000 (y=1.005x-0.001), where the Intoxilyzer 5000 and the Intoxilyzer 8000 were plotted on the x- and y-axis respectively. Instrument response to mouth alcohol and volatile interferences was also investigated. Potential interferences were evaluated alone or in combination with ethanol using a wet bath simulator at

  17. Validation of a new mixing chamber system for breath-by-breath indirect calorimetry.

    PubMed

    Kim, Do-Yeon; Robergs, Robert Andrew

    2012-02-01

    Limited validation research exists for applications of breath-by-breath systems of expired gas analysis indirect calorimetry (EGAIC) during exercise. We developed improved hardware and software for breath-by-breath indirect calorimetry (NEW) and validated this system as well as a commercial system (COM) against 2 methods: (i) mechanical ventilation with known calibration gas, and (ii) human subjects testing for 5 min each at rest and cycle ergometer exercise at 100 and 175 W. Mechanical calibration consisted of medical grade and certified calibration gas ((4.95% CO(2), 12.01% O(2), balance N(2)), room air (20.95% O(2), 0.03% CO(2), balance N(2)), and 100% nitrogen), and an air flow turbine calibrated with a 3-L calibration syringe. Ventilation was mimicked manually using complete 3-L calibration syringe manouvers at a rate of 10·min(-1) from a Douglas bag reservoir of calibration gas. The testing of human subjects was completed in a counterbalanced sequence based on 5 repeated tests of all conditions for a single subject. Rest periods of 5 and 10 min followed the 100 and 175 W conditions, respectively. COM and NEW had similar accuracy when tested with known ventilation and gas fractions. However, during human subjects testing COM significantly under-measured carbon dioxide gas fractions, over-measured oxygen gas fractions and minute ventilation, and resulted in errors to each of oxygen uptake, carbon dioxide output, and respiratory exchange ratio. These discrepant findings reveal that controlled ventilation and gas fractions are insufficient to validate breath-by-breath, and perhaps even time-averaged, systems of EGAIC. The errors of the COM system reveal the need for concern over the validity of commercial systems of EGAIC.

  18. Individuality of breathing during volitional moderate hyperventilation.

    PubMed

    Besleaga, Tudor; Blum, Michaël; Briot, Raphaël; Vovc, Victor; Moldovanu, Ion; Calabrese, Pascale

    2016-01-01

    The aim of this study is to investigate the individuality of airflow shapes during volitional hyperventilation. Ventilation was recorded on 18 healthy subjects following two protocols: (1) spontaneous breathing (SP1) followed by a volitional hyperventilation at each subject's spontaneous (HVSP) breathing rate, (2) spontaneous breathing (SP2) followed by hyperventilation at 20/min (HV20). HVSP and HV20 were performed at the same level of hypocapnia: end tidal CO2 (FETCO2) was maintained at 1% below the spontaneous level. At each breath, the tidal volume (VT), the breath (TTOT), the inspiratory (TI) and expiratory durations, the minute ventilation, VT/TI, TI/TTOT and the airflow shape were quantified by harmonic analysis. Under different conditions of breathing, we test if the airflow profiles of the same individual are more similar than airflow profiles between individuals. Minute ventilation was not significantly different between SP1 (6.71 ± 1.64 l·min(-1)) and SP2 (6.57 ± 1.31 l·min(-1)) nor between HVSP (15.88 ± 4.92 l·min(-1)) and HV20 (15.87 ± 4.16 l·min(-1)). Similar results were obtained for FETCO2 between SP1 (5.06 ± 0.54 %) and SP2 (5.00 ± 0.51%), and HVSP (4.07 ± 0.51%) and HV20 (3.88 ± 0.42%). Only TI/TTOT remained unchanged in all four conditions. Airflow shapes were similar when comparing SP1-SP2, HVSP-HV20, and SP1-HVSP but not similar when comparing SP2-HV20. These results suggest the existence of an individuality of airflow shape during volitional hyperventilation. We conclude that volitional ventilation alike automatic breathing follows inherent properties of the ventilatory system. Registered by Pascale Calabrese on ClinicalTrials.gov, # NCT01881945.

  19. 49 CFR 40.277 - Are alcohol tests other than saliva or breath permitted under these regulations?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Are alcohol tests other than saliva or breath... Testing § 40.277 Are alcohol tests other than saliva or breath permitted under these regulations? No.... Only saliva or breath for screening tests and breath for confirmation tests using approved devices are...

  20. 49 CFR 40.277 - Are alcohol tests other than saliva or breath permitted under these regulations?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false Are alcohol tests other than saliva or breath... Testing § 40.277 Are alcohol tests other than saliva or breath permitted under these regulations? No.... Only saliva or breath for screening tests and breath for confirmation tests using approved devices are...

  1. Identification of risk factors for pancreatic exocrine insufficiency after pancreaticoduodenectomy using a 13C-labeled mixed triglyceride breath test.

    PubMed

    Hirono, Seiko; Murakami, Yoshiaki; Tani, Masaji; Kawai, Manabu; Okada, Ken-ichi; Uemura, Kenichiro; Sudo, Takeshi; Hashimoto, Yasushi; Nakagawa, Naoya; Kondo, Naru; Yamaue, Hiroki

    2015-02-01

    There are only a few reports concerning long-term exocrine function after pancreaticoduodenectomy (PD), although the number of long-term survivors has increased. We assessed pancreatic exocrine function after PD in 189 patients to identify risk factors for pancreatic exocrine insufficiency. We evaluated patients' exocrine function by using the (13)C-labeled mixed triglyceride breath test, a noninvasive test feasible in outpatient service units. The present study included 99 patients that underwent pancreaticojejunostomy (PJ) at Wakayama Medical University Hospital and 90 patients that underwent pancreaticogastrostomy (PG) at Hiroshima University Hospital, the standard reconstruction techniques during PD at the respective hospitals. We also analyzed long-term morphological changes of remnant pancreas by computed tomography (main pancreatic duct dilation and parenchymal atrophy), nutritional status, and endocrine function. Independent risk factors for exocrine insufficiency after PD include hard pancreas (P = 0.003, odds ratio; 3.157) and PG reconstruction (P = 0.040, odds ratio; 2.321). Breath test results correlated significantly with post-operative morphological changes, nutritional status, and endocrine function. Atrophic changes of the remnant pancreas in the PG group were more severe than those in the PJ group. Furthermore, for patients with a soft pancreas, postoperative body weight changes, prognostic nutritional index, serum total protein levels as well as exocrine test were worse in the PG group, compared with the PJ group. Our results showed that PJ reconstruction might be superior to PG during PD, from the viewpoint of long-term pancreatic exocrine function, although further prospective studies are needed.

  2. Compressed air demand-type firefighter's breathing system, volume 1. [design analysis and performance tests

    NASA Technical Reports Server (NTRS)

    Sullivan, J. L.

    1975-01-01

    The commercial availability of lightweight high pressure compressed air vessels has resulted in a lightweight firefighter's breathing apparatus. The improved apparatus, and details of its design and development are described. The apparatus includes a compact harness assembly, a backplate mounted pressure reducer assembly, a lightweight bubble-type facemask with a mask mounted demand breathing regulator. Incorporated in the breathing regulator is exhalation valve, a purge valve and a whistle-type low pressure warning that sounds only during inhalation. The pressure reducer assembly includes two pressure reducers, an automatic transfer valve and a signaling device for the low pressure warning. Twenty systems were fabricated, tested, refined through an alternating development and test sequence, and extensively examined in a field evaluation program. Photographs of the apparatus are included.

  3. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  4. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  5. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  6. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  7. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  8. Oxidation of linoleic and palmitic acid in pre-hibernating and hibernating common noctule bats revealed by 13C breath testing.

    PubMed

    Rosner, Elisabeth; Voigt, Christian C

    2018-02-19

    Mammals fuel hibernation by oxidizing saturated and unsaturated fatty acids from triacylglycerols in adipocytes, yet the relative importance of these two categories as an oxidative fuel may change during hibernation. We studied the selective use of fatty acids as an oxidative fuel in noctule bats ( Nyctalus noctula ). Pre-hibernating noctule bats that were fed 13 C-enriched linoleic acid (LA) showed 12 times higher tracer oxidation rates compared with conspecifics fed 13 C-enriched palmitic acid (PA). After this experiment, we supplemented the diet of bats with the same fatty acids on five subsequent days to enrich their fat depots with the respective tracer. We then compared the excess 13 C enrichment (excess atom percentage, APE) in breath of bats for torpor and arousal events during early and late hibernation. We observed higher APE values in breath of bats fed 13 C-enriched LA than in bats fed 13 C-enriched PA for both states (torpor and arousal), and also for both periods. Thus, hibernating bats selectively oxidized endogenous LA instead of PA, probably because of faster transportation rates of polyunsaturated fatty acids compared with saturated fatty acids. We did not observe changes in APE values in the breath of torpid animals between early and late hibernation. Skin temperature of torpid animals increased by 0.7°C between early and late hibernation in bats fed PA, whereas it decreased by -0.8°C in bats fed LA, highlighting that endogenous LA may fulfil two functions when available in excess: serving as an oxidative fuel and supporting cell membrane functionality. © 2018. Published by The Company of Biologists Ltd.

  9. Mechanisms linking metabolism of Helicobacter pylori to 18O and 13C-isotopes of human breath CO2

    PubMed Central

    Som, Suman; De, Anulekha; Banik, Gourab Dutta; Maity, Abhijit; Ghosh, Chiranjit; Pal, Mithun; Daschakraborty, Sunil B.; Chaudhuri, Sujit; Jana, Subhra; Pradhan, Manik

    2015-01-01

    The gastric pathogen Helicobacter pylori utilize glucose during metabolism, but the underlying mechanisms linking to oxygen-18 (18O) and carbon-13 (13C)-isotopic fractionations of breath CO2 during glucose metabolism are poorly understood. Using the excretion dynamics of 18O/16O and 13C/12C-isotope ratios of breath CO2, we found that individuals with Helicobacter pylori infections exhibited significantly higher isotopic enrichments of 18O in breath CO2 during the 2h-glucose metabolism regardless of the isotopic nature of the substrate, while no significant enrichments of 18O in breath CO2 were manifested in individuals without the infections. In contrast, the 13C-isotopic enrichments of breath CO2 were significantly higher in individuals with Helicobacter pylori compared to individuals without infections in response to 13C-enriched glucose uptake, whereas a distinguishable change of breath 13C/12C-isotope ratios was also evident when Helicobacter pylori utilize natural glucose. Moreover, monitoring the 18O and 13C-isotopic exchange in breath CO2 successfully diagnosed the eradications of Helicobacter pylori infections following a standard therapy. Our findings suggest that breath 12C18O16O and 13C16O16O can be used as potential molecular biomarkers to distinctively track the pathogenesis of Helicobacter pylori and also for eradication purposes and thus may open new perspectives into the pathogen’s physiology along with isotope-specific non-invasive diagnosis of the infection. PMID:26039789

  10. The Effect of Alcohol-Based Hand Sanitizer Vapors on Evidential Breath Alcohol Test Results.

    PubMed

    Strawsine, Ellen; Lutmer, Brian

    2017-11-16

    This study was undertaken to determine if the application of alcohol-based hand sanitizers (ABHSs) to the hands of a breath test operator will affect the results obtained on evidential breath alcohol instruments (EBTs). This study obtained breath samples on three different EBTs immediately after application of either gel or foam ABHS to the operator's hands. A small, but significant, number of initial analyses (13 of 130, 10%) resulted in positive breath alcohol concentrations, while 41 samples (31.5%) resulted in a status code. These status codes were caused by ethanol vapors either in the room air or their inhalation by the subject, thereby causing a mouth alcohol effect. Replicate subject samples did not yield any consecutive positive numeric results. As ABHS application can cause a transitory mouth alcohol effect via inhalation of ABHS vapors, EBT operators should forego the use of ABHS in the 15 min preceding subject testing. © 2017 American Academy of Forensic Sciences.

  11. The glucose breath test: a diagnostic test for small bowel stricture(s) in Crohn's disease.

    PubMed

    Mishkin, Daniel; Boston, Francis M; Blank, David; Yalovsky, Morty; Mishkin, Seymour

    2002-03-01

    The aim of this study was to determine whether an indirect noninvasive indicator of proximal bacterial overgrowth, the glucose breath test, was of diagnostic value in inflammatory bowel disease. Twenty four of 71 Crohn's disease patients tested had a positive glucose breath test. No statistical conclusions could be drawn between the Crohn's disease activity index and glucose breath test status. Of patients with radiologic evidence of small bowel stricture(s), 96.0% had a positive glucose breath test, while only one of 46 negative glucose breath test patients had a stricture. The positive and negative predictive values for a positive glucose breath test as an indicator of stricture formation were 96.0% and 97.8%, respectively. This correlation was not altered in Crohn's disease patients with fistulae or status postresection of the terminal ileum. The data in ulcerative colitis were nondiagnostic. In conclusion, the glucose breath test appears to be an accurate noninvasive inexpensive diagnostic test for small bowel stricture(s) and secondary bacterial overgrowth in Crohn's disease.

  12. Update on diagnostic value of breath test in gastrointestinal and liver diseases

    PubMed Central

    Siddiqui, Imran; Ahmed, Sibtain; Abid, Shahab

    2016-01-01

    In the field of gastroenterology, breath tests (BTs) are used intermittently as diagnostic tools that allow indirect, non-invasive and relatively less cumbersome evaluation of several disorders by simply quantifying the appearance in exhaled breath of a metabolite of a specific substrate administered. The aim of this review is to have an insight into the principles, methods of analysis and performance parameters of various hydrogen, methane and carbon BTs which are available for diagnosing gastrointestinal disorders such as Helicobacter pylori infection, small intestinal bacterial overgrowth, and carbohydrate malabsorption. Evaluation of gastric emptying is routinely performed by scintigraphy which is however, difficult to perform and not suitable for children and pregnant women, this review has abridged the 13C-octanoic acid test in comparison to scintigraphy and has emphasized on its working protocol and challenges. A new development such as electronic nose test is also highlighted. Moreover we have also explored the limitations and constraints restraining the wide use of these BT. We conclude that breath testing has an enormous potential to be used as a diagnostic modality. In addition it offers distinct advantages over the traditional invasive methods commonly employed. PMID:27574563

  13. Clinical significance of the glucose breath test in patients with inflammatory bowel disease.

    PubMed

    Lee, Ji Min; Lee, Kang-Moon; Chung, Yoon Yung; Lee, Yang Woon; Kim, Dae Bum; Sung, Hea Jung; Chung, Woo Chul; Paik, Chang-Nyol

    2015-06-01

    Small intestinal bacterial overgrowth which has recently been diagnosed with the glucose breath test is characterized by excessive colonic bacteria in the small bowel, and results in gastrointestinal symptoms that mimic symptoms of inflammatory bowel disease. This study aimed to estimate the positivity of the glucose breath test and investigate its clinical role in inflammatory bowel disease. Patients aged > 18 years with inflammatory bowel disease were enrolled. All patients completed symptom questionnaires. Fecal calprotectin level was measured to evaluate the disease activity. Thirty historical healthy controls were used to determine normal glucose breath test values. A total of 107 patients, 64 with ulcerative colitis and 43 with Crohn's disease, were included. Twenty-two patients (20.6%) were positive for the glucose breath test (30.2%, Crohn's disease; 14.1%, ulcerative colitis). Positive rate of the glucose breath test was significantly higher in patients with Crohn's disease than in healthy controls (30.2% vs 6.7%, P=0.014). Bloating, flatus, and satiety were higher in glucose breath test-positive patients than glucose breath test-negative patients (P=0.021, 0.014, and 0.049, respectively). The positivity was not correlated with the fecal calprotectin level. The positive rate of the glucose breath test was higher in patients with inflammatory bowel disease, especially Crohn's disease than in healthy controls; gastrointestinal symptoms of patients with inflammatory bowel disease were correlated with this positivity. Glucose breath test can be used to manage intestinal symptoms of patients with inflammatory bowel disease. © 2015 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  14. 13C-breath tests for sucrose digestion in congenital sucrase isomaltase-deficient and sacrosidase-supplemented patients

    USDA-ARS?s Scientific Manuscript database

    Congenital sucrase-isomaltase deficiency (CSID) is characterized by absence or deficiency of the mucosal sucrase-isomaltase enzyme. Specific diagnosis requires upper gastrointestinal biopsy with evidence of low to absent sucrase enzyme activity and normal histology. The hydrogen breath test (BT) is ...

  15. Breath tests and irritable bowel syndrome

    PubMed Central

    Rana, Satya Vati; Malik, Aastha

    2014-01-01

    Breath tests are non-invasive tests and can detect H2 and CH4 gases which are produced by bacterial fermentation of unabsorbed intestinal carbohydrate and are excreted in the breath. These tests are used in the diagnosis of carbohydrate malabsorption, small intestinal bacterial overgrowth, and for measuring the orocecal transit time. Malabsorption of carbohydrates is a key trigger of irritable bowel syndrome (IBS)-type symptoms such as diarrhea and/or constipation, bloating, excess flatulence, headaches and lack of energy. Abdominal bloating is a common nonspecific symptom which can negatively impact quality of life. It may reflect dietary imbalance, such as excess fiber intake, or may be a manifestation of IBS. However, bloating may also represent small intestinal bacterial overgrowth. Patients with persistent symptoms of abdominal bloating and distension despite dietary interventions should be referred for H2 breath testing to determine the presence or absence of bacterial overgrowth. If bacterial overgrowth is identified, patients are typically treated with antibiotics. Evaluation of IBS generally includes testing of other disorders that cause similar symptoms. Carbohydrate malabsorption (lactose, fructose, sorbitol) can cause abdominal fullness, bloating, nausea, abdominal pain, flatulence, and diarrhea, which are similar to the symptoms of IBS. However, it is unclear if these digestive disorders contribute to or cause the symptoms of IBS. Research studies show that a proper diagnosis and effective dietary intervention significantly reduces the severity and frequency of gastrointestinal symptoms in IBS. Thus, diagnosis of malabsorption of these carbohydrates in IBS using a breath test is very important to guide the clinician in the proper treatment of IBS patients. PMID:24976698

  16. Breathing patterns in preterm and term infants immediately after birth.

    PubMed

    te Pas, Arjan B; Wong, Connie; Kamlin, C Omar F; Dawson, Jennifer A; Morley, Colin J; Davis, Peter G

    2009-03-01

    There is limited data describing how preterm and term infants breathe spontaneously immediately after birth. We studied spontaneously breathing infants >or=29 wk immediately after birth. Airway flow and tidal volume were measured for 90 s using a hot wire anemometer attached to a facemask. Twelve preterm and 13 term infants had recordings suitable for analysis. The median (interquartile range) proportion of expiratory braking was very high in both groups (preterm 90 [74-99] vs. term 87 [74-94]%; NS). Crying pattern was the predominant breathing pattern for both groups (62 [36-77]% vs. 64 [46-79]%; NS). Preterm infants showed a higher incidence of expiratory hold pattern (9 [4-17]% vs. 2 [0-6]%; p = 0.02). Both groups had large tidal volumes (6.7 [3.9] vs. 6.5 [4.1] mL/kg), high peak inspiratory flows (5.7 [3.8] vs. 8.0 [5] L/min), lower peak expiratory flow (3.6 [2.4] vs. 4.8 [3.2] L/min), short inspiration time (0.31 [0.13] vs. 0.32 [0.16] s) and long expiration time (0.93 [0.64] vs. 1.14 [0.86] s). Directly after birth, both preterm and term infants frequently brake their expiration, mostly by crying. Preterm infants use significantly more expiratory breath holds to defend their lung volume.

  17. Data Mining Techniques Applied to Hydrogen Lactose Breath Test.

    PubMed

    Rubio-Escudero, Cristina; Valverde-Fernández, Justo; Nepomuceno-Chamorro, Isabel; Pontes-Balanza, Beatriz; Hernández-Mendoza, Yoedusvany; Rodríguez-Herrera, Alfonso

    2017-01-01

    Analyze a set of data of hydrogen breath tests by use of data mining tools. Identify new patterns of H2 production. Hydrogen breath tests data sets as well as k-means clustering as the data mining technique to a dataset of 2571 patients. Six different patterns have been extracted upon analysis of the hydrogen breath test data. We have also shown the relevance of each of the samples taken throughout the test. Analysis of the hydrogen breath test data sets using data mining techniques has identified new patterns of hydrogen generation upon lactose absorption. We can see the potential of application of data mining techniques to clinical data sets. These results offer promising data for future research on the relations between gut microbiota produced hydrogen and its link to clinical symptoms.

  18. Exercise training improves breathing strategy and performance during the six-minute walk test in obese adolescents.

    PubMed

    Mendelson, Monique; Michallet, Anne-Sophie; Perrin, Claudine; Levy, Patrick; Wuyam, Bernard; Flore, Patrice

    2014-08-15

    We aimed to examine ventilatory responses during the six-minute walk test in healthy-weight and obese adolescents before and after exercise training. Twenty obese adolescents (OB) (age: 14.5±1.7 years; BMI: 34.0±4.7kg·m(-2)) and 20 age and gender-matched healthy-weight adolescents (HW) (age: 15.5±1.5 years; BMI: 19.9±1.4kg·m(-2)) completed six-minute walk test during which breath-by-breath gas analysis and expiratory flow limitation (expFL) were measured. OB participated in a 12-week exercise-training program. Comparison between HW and OB participants showed lower distance achieved during the 6MWT in OB (-111.0m, 95%CI: -160.1 to 62.0, p<0.05) and exertional breathlessness was greater (+0.78 a.u., 95%CI: 0.091-3.27, p=0.039) when compared with HW. Obese adolescents breathed at lower lung volumes, as evidenced by lower end expiratory and end inspiratory lung volumes during exercise (p<0.05). Prevalence of expFL (8 OB vs 2 HW, p=0.028) and mean expFL (14.9±21.9 vs 5.32±14.6% VT, p=0.043, in OB and HW) were greater in OB. After exercise training, mean increase in the distance achieved during the 6MWT was 64.5 meters (95%CI: 28.1-100.9, p=0.014) and mean decrease in exertional breathlessness was 1.62 (95%CI: 0.47-2.71, p=0.05). Obese adolescents breathed at higher lung volumes, as evidenced by the increase in end inspiratory lung volume from rest to 6-min exercise (9.9±13.4 vs 20.0±13.6%TLC, p<0.05). Improved performance was associated with improved change in end inspiratory lung volume from rest to 6-min exercise (r=0.65, p=0.025). Our results suggest that exercise training can improve breathing strategy during submaximal exercise in obese adolescents and that this increase is associated with greater exercise performance. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Outcome of breath tests in adult patients with suspected small intestinal bacterial overgrowth

    PubMed Central

    Mattsson, Johanna; Minaya, Maria Teresa; Monegro, Milka; Lebwohl, Benjamin; Lewis, Suzanne K.; Green, Peter HR; Stenberg, Reidun

    2017-01-01

    Aim: The aim was to investigate breath test outcomes in patients with suspected SIBO and indicative symptoms of SIBO, diagnosed by breath testing. Background: Breath testing is used to detect small intestinal bacterial overgrowth (SIBO) by measuring hydrogen and methane produced by intestinal bacteria. Methods: This retrospective cross sectional study included 311 patients with gastrointestinal symptoms who underwent the breath test for evaluation of SIBO at Celiac Disease Center at Columbia University, New York, in 2014-2015. The patients were divided into two groups based on the physician’s choice: lactulose breath test group (72%) and glucose breath test group (28%). Among them, 38% had a history of celiac disease or non-celiac gluten sensitivity. Results: In total, 46% had a positive breath test: 18% were positive for methane, 24 % positive for hydrogen and 4% positive for both gases (p=0.014). Also, 50% had a positive lactulose breath result and 37% had a positive glucose breath result (p=0.036). The most common symptom for performing the breath test was bloating and the only clinical symptom that significantly showed a positive glucose breath test was increased gas (p=0.028). Conclusion: Lactulose breath test was more often positive than glucose breath test. Positivity for hydrogen was more common than methane. Bloating was the most frequently perceived symptom of the patients undergoing the breath test but the only statistically significant clinical symptom for a positive glucose breath test was increased gas. Furthermore, the results showed that there was no significant association between positive breath test result and gender, age, non-celiac gluten sensitivity or celiac disease. PMID:29118931

  20. Medical Diagnostic Breath Analysis by Cavity Ring Down Spectroscopy

    NASA Astrophysics Data System (ADS)

    Guss, Joseph S.; Metsälä, Markus; Halonen, Lauri

    2009-06-01

    Certain medical conditions give rise to the presence of chemicals in the bloodstream. These chemicals - known as biomarkers - may also be present in low concentrations in human breath. Cavity ring down spectroscopy possesses the requisite selectivity and sensitivity to detect such biomarkers in the congested spectrum of a breath sample. The ulcer-causing bacterium, Helicobacter pylori, is a prolific producer of the enzyme urease, which catalyses the breakdown of urea ((NH_2)_2CO) in the stomach as follows: (NH_2)_2CO + H_2O ⟶ CO_2 + 2NH_3 Currently, breath tests seeking altered carbon-isotope ratios in exhaled CO_2 after the ingestion of ^{13}C- or ^{14}C-labeled urea are used to diagnose H. pylori infection. We present recent results from an ongoing collaboration with Tampere Area University Hospital. The study involves 100 patients (both infected and uninfected) and concerns the possible correlation between the bacterial infection and breath ammonia. D. Y. Graham, P. D. Klein, D. J. Evans, Jr, D. G. Evans, L. C. Alpert, A. R. Opekun, T. W. Boutton, Lancet 1(8543), 1174-7 March 1987.

  1. CaV1.3 L-type Ca2+ channels modulate depression-like behaviour in mice independent of deaf phenotype.

    PubMed

    Busquet, Perrine; Nguyen, Ngoc Khoi; Schmid, Eduard; Tanimoto, Naoyuki; Seeliger, Mathias W; Ben-Yosef, Tamar; Mizuno, Fengxia; Akopian, Abram; Striessnig, Jörg; Singewald, Nicolas

    2010-05-01

    Mounting evidence suggests that voltage-gated L-type Ca2+ channels can modulate affective behaviour. We therefore explored the role of CaV1.3 L-type Ca2+ channels in depression- and anxiety-like behaviours using CaV1.3-deficient mice (CaV1.3-/-). We showed that CaV1.3-/- mice displayed less immobility in the forced swim test as well as in the tail suspension test, indicating an antidepressant-like phenotype. Locomotor activity in the home cage or a novel open-field test was not influenced. In the elevated plus maze (EPM), CaV1.3-/- mice entered the open arms more frequently and spent more time there indicating an anxiolytic-like phenotype which was, however, not supported in the stress-induced hyperthermia test. By performing parallel experiments in Claudin 14 knockout mice (Cldn14-/-), which like CaV1.3-/- mice are congenitally deaf, an influence of deafness on the antidepressant-like phenotype could be ruled out. On the other hand, a similar EPM behaviour indicative of an anxiolytic phenotype was also found in the Cldn14-/- animals. Using electroretinography and visual behavioural tasks we demonstrated that at least in mice, CaV1.3 channels do not significantly contribute to visual function. However, marked morphological changes were revealed in synaptic ribbons in the outer plexiform layer of CaV1.3-/- retinas by immunohistochemistry suggesting a possible role of this channel type in structural plasticity at the ribbon synapse. Taken together, our findings indicate that CaV1.3 L-type Ca2+ channels modulate depression-like behaviour but are not essential for visual function. The findings raise the possibility that selective modulation of CaV1.3 channels could be a promising new therapeutic concept for the treatment of mood disorders.

  2. Breathing simulator of workers for respirator performance test

    PubMed Central

    YUASA, Hisashi; KUMITA, Mikio; HONDA, Takeshi; KIMURA, Kazushi; NOZAKI, Kosuke; EMI, Hitoshi; OTANI, Yoshio

    2014-01-01

    Breathing machines are widely used to evaluate respirator performance but they are capable of generating only limited air flow patterns, such as, sine, triangular and square waves. In order to evaluate the respirator performance in practical use, it is desirable to test the respirator using the actual breathing patterns of wearers. However, it has been a difficult task for a breathing machine to generate such complicated flow patterns, since the human respiratory volume changes depending on the human activities and workload. In this study, we have developed an electromechanical breathing simulator and a respiration sampling device to record and reproduce worker’s respiration. It is capable of generating various flow patterns by inputting breathing pattern signals recorded by a computer, as well as the fixed air flow patterns. The device is equipped with a self-control program to compensate the difference in inhalation and exhalation volume and the measurement errors on the breathing flow rate. The system was successfully applied to record the breathing patterns of workers engaging in welding and reproduced the breathing patterns. PMID:25382381

  3. Breathing simulator of workers for respirator performance test.

    PubMed

    Yuasa, Hisashi; Kumita, Mikio; Honda, Takeshi; Kimura, Kazushi; Nozaki, Kosuke; Emi, Hitoshi; Otani, Yoshio

    2015-01-01

    Breathing machines are widely used to evaluate respirator performance but they are capable of generating only limited air flow patterns, such as, sine, triangular and square waves. In order to evaluate the respirator performance in practical use, it is desirable to test the respirator using the actual breathing patterns of wearers. However, it has been a difficult task for a breathing machine to generate such complicated flow patterns, since the human respiratory volume changes depending on the human activities and workload. In this study, we have developed an electromechanical breathing simulator and a respiration sampling device to record and reproduce worker's respiration. It is capable of generating various flow patterns by inputting breathing pattern signals recorded by a computer, as well as the fixed air flow patterns. The device is equipped with a self-control program to compensate the difference in inhalation and exhalation volume and the measurement errors on the breathing flow rate. The system was successfully applied to record the breathing patterns of workers engaging in welding and reproduced the breathing patterns.

  4. Breath test refusals and DWI prosecution : traffic tech.

    DOT National Transportation Integrated Search

    2012-08-01

    There are typically about 1.4 million DWI (driving while : impaired) arrests each year in the United States. An officers : request to a driver for a breath (or blood, or urine) test is an : important part of the arrest process. The percentage of d...

  5. Comparison of breath gases, including acetone, with blood glucose and blood ketones in children and adolescents with type 1 diabetes.

    PubMed

    Blaikie, Tom P J; Edge, Julie A; Hancock, Gus; Lunn, Daniel; Megson, Clare; Peverall, Rob; Richmond, Graham; Ritchie, Grant A D; Taylor, David

    2014-11-25

    Previous studies have suggested that breath gases may be related to simultaneous blood glucose and blood ketone levels in adults with type 2 and type 1 diabetes. The aims of this study were to investigate these relationships in children and young people with type 1 diabetes in order to assess the efficacy of a simple breath test as a non-invasive means of diabetes management. Gases were collected in breath bags and measurements were compared with capillary blood glucose and ketone levels taken at the same time on a single visit to a routine hospital clinic in 113 subjects (59 male, age 7 years 11 months-18 years 3 months) with type 1 diabetes. The patients were well-controlled with relatively low concentrations of the blood ketone measured (β hydroxybutyrate, 0-0.4 mmol l(-1)). Breath acetone levels were found to increase with blood β hydroxybutyrate levels and a significant relationship was found between the two (Spearman's rank correlation ρ = 0.364, p < 10(-4)). A weak positive relationship was found between blood glucose and breath acetone (ρ = 0.16, p = 0.1), but led to the conclusion that single breath measurements of acetone do not provide a good measure of blood glucose levels in this cohort. This result suggests a potential to develop breath gas analysis to provide an alternative to blood testing for ketone measurement, for example to assist with the management of type 1 diabetes.

  6. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  7. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  8. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  9. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  10. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  11. Utilization of [14C]phenylalanine derived from arylphorin or free amino acid in Manduca sexta pharate adults

    NASA Technical Reports Server (NTRS)

    Wu, M.; Tischler, M. E.

    1995-01-01

    The role of arylphorin as a storage protein was studied using 14C-arylphorin. 14C-arylphorin was produced optimally by incubating one-half fat body from Manduca sexta fifth instar larvae at 22 degrees C for 24 h, in 1 ml of medium containing amino acids at 25% of their physiological concentration with [U-14C]-phenylalanine (phe) provided initially without nonlabeled phenylalanine. Nonlabeled phe was provided after 1 h at 16% of its physiological concentration. The specific activity of 14C-arylphorin produced in vitro was 30 times greater than that generated in vivo. Injection of 14C-arylphorin into pharate adults was used to study the distribution of 14C-phe derived from this protein into 14CO2 and tissues for comparison with injection of free 14C-phe during the middle (days 6 to 12 pharate adult) and late (days 12 to 17 pharate adult) stages of adult development. Appearance of 14CO2 from 14C-arylphorin as compared to 14C-phenylalanine showed a slower time course during both the middle and late stages of development, in keeping with the time needed for degradation of the protein. In accord with faster phe turnover near the end of adult development, total 14CO2 production was greater and the retention of 14C in hemolymph and fat body was less compared to the middle stage of development regardless of whether 14C-arylphorin or 14C-phe was injected. In the middle stage of development, the appearance of 14C in the cuticle and head parts was greater, whereas incorporation into abdomen and thorax was less than during the late stage of development. Since the pattern of 14C distribution from 14C-arylphorin and 14C-phe was similar, one major function of arylphorin must be as a storage protein replenishing the supply of free amino acids used for synthesis of adult tissues. These results also suggest a limited contribution of M. sexta arylphorin to formation of the cuticle subsequent to day-6 pharate adult.

  12. [Application of the breath hydrogen test in gastroenterology].

    PubMed

    Loranskaia, I D; Panina, N A; Zheltakova, O V

    2006-01-01

    The diagnostic capacities of the breath hydrogen test in gastroenterology are discussed in the article. The authors describe the results of their own research--determination of the intestinal bacterial contamination in patients with chronic biliary pancreatitis with the help of the Micro H2 breath hydrogen analyzer.

  13. Fourier-transformed infrared breath testing after ingestion of technical alcohol.

    PubMed

    Laakso, Olli; Haapala, Matti; Pennanen, Teemu; Kuitunen, Tapio; Himberg, Jaakko-Juhani

    2007-07-01

    The study aim was to evaluate the feasibility of a Fourier-transformed infrared (FT-IR) analyzer for out-of-laboratory use by screening the exhalations of inebriated individuals, and to determine analysis quality using common breath components and solvents. Each of the 35 inebriated participants gave an acceptable sample. Because of the metabolism of 2-propanol, the subjects exhaled high concentrations of acetone in addition to ethanol. Other volatile ingredients of technical ethanol products (methyl ethyl ketone, methyl isobutyl ketone, and 2-propanol) were also detected. The lower limits of quantification for the analyzed components ranged from 1.7 to 12 microg/L in simulated breath samples. The bias was +/-2% for ethanol and -11% for methanol. Within-day and between-day coefficients of variation were <1% for ethanol and <4% for methanol. The bias of ethanol and methanol analyses due to coexisting solvents ranged from -0.8 to +2.2% and from -5.6 to +2.9%, respectively. The FT-IR method proved suitable for use outside the laboratory and fulfilled the quality criteria for analysis of solvents in breath.

  14. Influence of breathing resistance of heat and moisture exchangers on tracheal climate and breathing pattern in laryngectomized individuals.

    PubMed

    Scheenstra, Renske J; Muller, Sara H; Vincent, Andrew; Sinaasappel, Michiel; Hilgers, Frans J M

    2010-08-01

    The aim of this study was to determine the influence of breathing resistance of heat and moisture exchangers (HMEs) on endotracheal climate and breathing pattern. Endotracheal temperature and humidity and tidal volumes were measured in 11 laryngectomized patients with a regularly used HME with "standard" breathing resistance (Provox Normal HME; R-HME), a low breathing-resistance HME (Provox HiFlow HME; L-HME), and without HME. Both R-HME and L-HME increased end-inspiratory humidity (+5.8 and 4.7 mgH(2)O/L, respectively), decreased end-inspiratory temperature (-1.6 and -1.0 degrees C, respectively), and prolonged the exhalation breath length to approximately 0.5 seconds. The R-HME significantly enlarged tidal volumes (0.07 L; p < .05). Both HMEs significantly improve tracheal climate. The R-HME has better moistening properties and a small but significant positive effect on tidal volume. Therefore, if the higher resistance is tolerated, the R-HME is the preferred pulmonary rehabilitation device. The L-HME is indicated if lower breathing resistance is required. 2009 Wiley Periodicals, Inc. Head Neck, 2010.

  15. Diagnostic accuracy of level 3 portable sleep tests versus level 1 polysomnography for sleep-disordered breathing: a systematic review and meta-analysis

    PubMed Central

    El Shayeb, Mohamed; Topfer, Leigh-Ann; Stafinski, Tania; Pawluk, Lawrence; Menon, Devidas

    2014-01-01

    Background: Greater awareness of sleep-disordered breathing and rising obesity rates have fueled demand for sleep studies. Sleep testing using level 3 portable devices may expedite diagnosis and reduce the costs associated with level 1 in-laboratory polysomnography. We sought to assess the diagnostic accuracy of level 3 testing compared with level 1 testing and to identify the appropriate patient population for each test. Methods: We conducted a systematic review and meta-analysis of comparative studies of level 3 versus level 1 sleep tests in adults with suspected sleep-disordered breathing. We searched 3 research databases and grey literature sources for studies that reported on diagnostic accuracy parameters or disease management after diagnosis. Two reviewers screened the search results, selected potentially relevant studies and extracted data. We used a bivariate mixed-effects binary regression model to estimate summary diagnostic accuracy parameters. Results: We included 59 studies involving a total of 5026 evaluable patients (mostly patients suspected of having obstructive sleep apnea). Of these, 19 studies were included in the meta-analysis. The estimated area under the receiver operating characteristics curve was high, ranging between 0.85 and 0.99 across different levels of disease severity. Summary sensitivity ranged between 0.79 and 0.97, and summary specificity ranged between 0.60 and 0.93 across different apnea–hypopnea cut-offs. We saw no significant difference in the clinical management parameters between patients who underwent either test to receive their diagnosis. Interpretation: Level 3 portable devices showed good diagnostic performance compared with level 1 sleep tests in adult patients with a high pretest probability of moderate to severe obstructive sleep apnea and no unstable comorbidities. For patients suspected of having other types of sleep-disordered breathing or sleep disorders not related to breathing, level 1 testing remains the

  16. sup 14 C-urea breath test for the detection of Helicobacter pylori

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veldhuyzen van Zanten, S.J.; Tytgat, K.M.; Hollingsworth, J.

    1990-04-01

    The high urease activity of Helicobacter pylori can be used to detect this bacterium by noninvasive breath tests. We have developed a {sup 14}C-urea breath test which uses 5 microCi {sup 14}C with 50 mg nonradioactive urea. Breath samples are collected at baseline and every 30 min for 2 h. Our study compared the outcome of the breath test to the results of histology and culture of endoscopically obtained gastric biopsies in 84 patients. The breath test discriminated well between the 50 positive patients and the 34 patients negative for Helicobacter pylori: the calculated sensitivity was 100%, specificity 88%, positivemore » predictive value 93%, and negative predictive value 100%. Treatment with bismuth subsalicylate and/or ampicillin resulted in lower counts of exhaled {sup 14}CO{sub 2} which correlated with histological improvement in gastritis. The {sup 14}C-urea breath test is a better gold standard for the detection of Helicobacter pylori than histology and/or culture.« less

  17. Study of ethane level in exhaled breath in patients with age-related macular degeneration: preliminary study.

    PubMed

    Cagini, C; Giordanelli, A; Fiore, T; Giardinieri, R; Malici, B; De Medio, G E; Pelli, M A; De Bellis, F; Capodicasa, E

    2011-01-01

    A variety of factors have been implicated in the pathogenesis of age-related macular degeneration (ARMD), and oxidative stress plays an important role in the onset and progression of the disease. Breath ethane is now considered a specific and non-invasive test for determining and monitoring the trend of lipid peroxidation and free radical-induced damage in vivo. This test provides an index of the patients' overall oxidative stress level. We evaluated the breath ethane concentration in exhaled air in patients with advanced ARMD. In this study, we enrolled 13 patients with advanced ARMD and a control group, and a breath analysis was carried out by gas chromatography. The mean ethane level in the ARMD patients was 0.82 ± 0.93 nmol/l (range: 0.01-2.7 nmol/l) and the mean ethane value in the control group was 0.12 ± 0.02 nmol/l (range: 0.08-0.16 nmol/l). The difference between the values of the 2 groups was statistically significant (p < 0.005). Receiver operating characteristic analysis showed an elevated area under the curve (0.831; 95% CI: 0.634-0.948), with a significance level of p < 0.0014 (area = 0.5). These preliminary results seem to indicate that breath ethane levels are higher in most patients with ARMD. The breath ethane test could thus be a useful method for evaluating the level of oxidative stress in patients with ARMD. To our knowledge, there are no data on this type of analysis applied to ARMD. Copyright © 2011 S. Karger AG, Basel.

  18. [Analysis of breath hydrogen (H2) in diagnosis of gastrointestinal function: validation of a pocket breath H2 test analyzer].

    PubMed

    Braden, B; Braden, C P; Klutz, M; Lembcke, B

    1993-04-01

    Breath hydrogen (H2) analysis, as used in gastroenterologic function tests, requires a stationary analysis system equipped with a gaschromatograph or an electrochemical sensor cell. Now a portable breath H2-analyzer has been miniaturized to pocket size (104 mm x 62 mm x 29 mm). The application of this device in clinical practice has been assessed in comparison to the standard GMI-exhaled monitor. The pocket analyzer showed a linear response to standards with H2-concentrations ranging from 0-100 ppm (n = 7), which was not different from the GMI-apparatus. The correlation of both methods during clinical application (lactose tolerance tests, mouth-to-coecum transit time determined with lactulose) was excellent (Y = 1.08 X + 0.96; r = 0.959). Using the new device, both, analysis (3 s vs. 90 s) and the reset-time (43 s vs. 140 s) were shorter whereas calibration was more feasible with the GMI-apparatus. It is concluded, that the considerably cheaper pocket-sized breath H2-analyzer is as precise and sensitive as the GMI-exhaled monitor, and thus presents a valid alternative for H2-breath tests.

  19. Operation and testing of Mark 10 Mod 3 underwater breathing apparatus

    NASA Technical Reports Server (NTRS)

    Milwee, W. I., Jr.

    1972-01-01

    Performance tests on a closed circuit, mixed gas underwater breathing apparatus are reported. The equipment is designed to provide a minimum diving duration of four hours at 1500 ft below sea surface; it senses oxygen partial pressure in the breathing gas mix and controls oxygen content of the breathing gas within narrow limits about a preset value. The breathing circuit subsystem provides respirable gas to the diver and removes carbon dioxide and moisture from the expired gas. Test results indicate undesirable variations in oxygen partial pressure with oxygen addition and insufficient carbon dioxide absorption.

  20. Application of LaserBreath-001 for breath acetone measurement in subjects with diabetes mellitus

    NASA Astrophysics Data System (ADS)

    Wang, Zhennan; Sun, Meixiu; Chen, Zhuying; Zhao, Xiaomeng; Li, Yingxin; Wang, Chuji

    2016-11-01

    Breath acetone is a promising biomarker of diabetes mellitus. With an integrated standalone, on-site cavity ringdown breath acetone analyzer, LaserBreath-001, we tested breath samples from 23 type 1 diabetic (T1D) patients, 312 type 2 diabetic (T2D) patients, 52 healthy subjects. In the cross-sectional studies, the obtained breath acetone concentrations were higher in the diabetic subjects compared with those in the control group. No correlation between breath acetone and simultaneous BG was observed in the T1D, T2D, and healthy subjects. A moderate positive correlation between the mean individual breath acetone concentrations and the mean individual BG levels was observed in the 20 T1D patients without ketoacidosis. In a longitudinal study, the breath acetone concentrations in a T1D patient with ketoacidosis decreased significantly and remained stable during the 5-day hospitalization. The results from a relatively large number of subjects tested indicate that an elevated mean breath acetone concentration exists in diabetic patients in general. Although many physiological parameters affect breath acetone concentrations, fast (<1 min) and on site breath acetone measurement can be used for diabetic screening and management under a specifically controlled condition.

  1. An acetone breath analyzer using cavity ringdown spectroscopy: an initial test with human subjects under various situations

    NASA Astrophysics Data System (ADS)

    Wang, Chuji; Surampudi, Anand B.

    2008-10-01

    We have developed a portable breath acetone analyzer using cavity ringdown spectroscopy (CRDS). The instrument was initially tested by measuring the absorbance of breath gases at a single wavelength (266 nm) from 32 human subjects under various conditions. A background subtraction method, implemented to obtain absorbance differences, from which an upper limit of breath acetone concentration was obtained, is described. The upper limits of breath acetone concentration in the four Type 1 diabetes (T1D) subjects, tested after a 14 h overnight fast, range from 0.80 to 3.97 parts per million by volume (ppmv), higher than the mean acetone concentration (0.49 ppmv) in non-diabetic healthy breath reported in the literature. The preliminary results show that the instrument can tell distinctive differences between the breath from individuals who are healthy and those with T1D. On-line monitoring of breath gases in healthy people post-exercise, post-meals and post-alcohol-consumption was also conducted. This exploratory study demonstrates the first CRDS-based acetone breath analyzer and its potential application for point-of-care, non-invasive, diabetic monitoring.

  2. Supplementing monosodium glutamate to partial enteral nutrition slows gastric emptying in preterm pigs(1-3).

    PubMed

    Bauchart-Thevret, Caroline; Stoll, Barbara; Benight, Nancy M; Olutoye, Oluyinka; Lazar, David; Burrin, Douglas G

    2013-05-01

    Emerging evidence suggests that free glutamate may play a functional role in modulating gastroduodenal motor function. We hypothesized that supplementing monosodium glutamate (MSG) to partial enteral nutrition stimulates gastric emptying in preterm pigs. Ten-day-old preterm, parenterally fed pigs received partial enteral nutrition (25%) as milk-based formula supplemented with MSG at 0, 1.7, 3.0, and 4.3 times the basal protein-bound glutamate intake (468 mg·kg(-1)·d(-1)) from d 4 to 8 of life (n = 5-8). Whole-body respiratory calorimetry and (13)C-octanoic acid breath tests were performed on d 4, 6, and 8. Body weight gain, stomach and intestinal weights, and arterial plasma glutamate and glutamine concentrations were not different among the MSG groups. Arterial plasma glutamate concentrations were significantly higher at birth than after 8 d of partial enteral nutrition. Also at d 8, the significant portal-arterial concentration difference in plasma glutamate was substantial (∼500 μmol/L) among all treatment groups, suggesting that there was substantial net intestinal glutamate absorption in preterm pigs. MSG supplementation dose-dependently increased gastric emptying time and decreased breath (13)CO2 enrichments, (13)CO2 production, percentage of (13)CO2 recovery/h, and cumulative percentage recovery of (13)C-octanoic acid. Circulating glucagon-like peptide-2 (GLP-2) concentration was significantly increased by MSG but was not associated with an increase in intestinal mucosal growth. In contrast to our hypothesis, our results suggest that adding MSG to partial enteral nutrition slows the gastric emptying rate, which may be associated with an inhibitory effect of increased circulating GLP-2.

  3. 42 CFR 84.152 - Breathing tube test; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...: (i) Be employed on Type C supplied-air respirators of the demand and pressure-demand class; and (ii... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.152 Breathing tube test; minimum requirements. (a)(1) Type A and Type B supplied-air...

  4. Retinal Vessel Oxygen Saturation during 100% Oxygen Breathing in Healthy Individuals

    PubMed Central

    Olafsdottir, Olof Birna; Eliasdottir, Thorunn Scheving; Kristjansdottir, Jona Valgerdur; Hardarson, Sveinn Hakon; Stefánsson, Einar

    2015-01-01

    Purpose To detect how systemic hyperoxia affects oxygen saturation in retinal arterioles and venules in healthy individuals. Methods Retinal vessel oxygen saturation was measured in 30 healthy individuals with a spectrophotometric retinal oximeter (Oxymap T1). Oximetry was performed during breathing of room air, 100% oxygen (10 minutes, 6L/min) and then again room air (10 minutes recovery). Results Mean oxygen saturation rises modestly in retinal arterioles during 100% oxygen breathing (94.5%±3.8 vs. 92.0%±3.7% at baseline, p<0.0001) and dramatically in retinal venules (76.2%±8.0% vs. 51.3%±5.6%, p<0.0001). The arteriovenous difference decreased during 100% oxygen breathing (18.3%±9.0% vs. 40.7%±5.7%, p<0.0001). The mean diameter of arterioles decreased during 100% oxygen breathing compared to baseline (9.7±1.4 pixels vs. 10.3±1.3 pixels, p<0.0001) and the same applies to the mean venular diameter (11.4±1.2 pixels vs. 13.3±1.5 pixels, p<0.0001). Conclusions Breathing 100% oxygen increases oxygen saturation in retinal arterioles and more so in venules and constricts them compared to baseline levels. The dramatic increase in oxygen saturation in venules reflects oxygen flow from the choroid and the unusual vascular anatomy and oxygen physiology of the eye. PMID:26042732

  5. 1. BUILDING 8698, TEST STAND 13, WEST ELEVATION. NOTE TUNNEL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. BUILDING 8698, TEST STAND 1-3, WEST ELEVATION. NOTE TUNNEL BETWEEN BLDG. 8668 AND TEST STAND 1-3. TEST AREA 1-120 IN THE MIDDLE DISTANCE, AND TEST AREA 1-125 ON THE HORIZON. Looking northeast from the roof of Building 8668, Instrumentation and Control Center. Note: Photograph CA-236-F-2 is an 8" x 10" enlargement from a 4" x 5" negative. This view is a photocopy of a recent resin coated print made from a print held at the Main Base History Office, Edwards Air Force Base, California. Photographer unknown. Date and file number unknown. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-3, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  6. L-arginine supplementation enhances exhaled NO, breath condensate VEGF, and headache at 4,342 m.

    PubMed

    Mansoor, Jim K; Morrissey, Brian M; Walby, William F; Yoneda, Ken Y; Juarez, Maya; Kajekar, Radhika; Severinghaus, John W; Eldridge, Marlowe W; Schelegle, Edward S

    2005-01-01

    We examined the effect of dietary supplementation with L-arginine on breath condensate VEGF, exhaled nitric oxide (NO), plasma erythropoietin, symptoms of acute mountain sickness, and respiratory related sensations at 4,342 m through the course of 24 h in seven healthy male subjects. Serum L-arginine levels increased in treated subjects at time 0, 8, and 24 h compared with placebo, indicating the effectiveness of our treatment. L-arginine had no significant effect on overall Lake Louise scores compared with placebo. However, there was a significant increase in headache within the L-arginine treatment group at 12 h compared with time 0, a change not seen in the placebo condition between these two time points. There was a trend (p = 0.087) toward greater exhaled NO and significant increases in breath condensate VEGF with L-arginine treatment, but no L-arginine effect on serum EPO. These results suggest that L-arginine supplementation increases HIF-1 stabilization in the lung, possibly through a NO-dependent pathway. In total, our observations indicate that L-arginine supplementation is not beneficial in the prophylactic treatment of AMS.

  7. Four-sample lactose hydrogen breath test for diagnosis of lactose malabsorption in irritable bowel syndrome patients with diarrhea

    PubMed Central

    Yang, Jian-Feng; Fox, Mark; Chu, Hua; Zheng, Xia; Long, Yan-Qin; Pohl, Daniel; Fried, Michael; Dai, Ning

    2015-01-01

    AIM: To validate 4-sample lactose hydrogen breath testing (4SLHBT) compared to standard 13-sample LHBT in the clinical setting. METHODS: Irritable bowel syndrome patients with diarrhea (IBS-D) and healthy volunteers (HVs) were enrolled and received a 10 g, 20 g, or 40 g dose lactose hydrogen breath test (LHBT) in a randomized, double-blinded, controlled trial. The lactase gene promoter region was sequenced. Breath samples and symptoms were acquired at baseline and every 15 min for 3 h (13 measurements). The detection rates of lactose malabsorption (LM) and lactose intolerance (LI) for a 4SLHBT that acquired four measurements at 0, 90, 120, and 180 min from the same data set were compared with the results of standard LHBT. RESULTS: Sixty IBS-D patients and 60 HVs were studied. The genotype in all participants was C/C-13910. LM and LI detection rates increased with lactose dose from 10 g, 20 g to 40 g in both groups (P < 0.001). 4SLHBT showed excellent diagnostic concordance with standard LHBT (97%-100%, Kappa​​ 0.815-0.942) with high sensitivity (90%-100%) and specificity (100%) at all three lactose doses in both groups. CONCLUSION: Reducing the number of measurements from 13 to 4 samples did not significantly impact on the accuracy of LHBT in health and IBS-D. 4SLHBT is a valid test for assessment of LM and LI in clinical practice. PMID:26140004

  8. Four-sample lactose hydrogen breath test for diagnosis of lactose malabsorption in irritable bowel syndrome patients with diarrhea.

    PubMed

    Yang, Jian-Feng; Fox, Mark; Chu, Hua; Zheng, Xia; Long, Yan-Qin; Pohl, Daniel; Fried, Michael; Dai, Ning

    2015-06-28

    To validate 4-sample lactose hydrogen breath testing (4SLHBT) compared to standard 13-sample LHBT in the clinical setting. Irritable bowel syndrome patients with diarrhea (IBS-D) and healthy volunteers (HVs) were enrolled and received a 10 g, 20 g, or 40 g dose lactose hydrogen breath test (LHBT) in a randomized, double-blinded, controlled trial. The lactase gene promoter region was sequenced. Breath samples and symptoms were acquired at baseline and every 15 min for 3 h (13 measurements). The detection rates of lactose malabsorption (LM) and lactose intolerance (LI) for a 4SLHBT that acquired four measurements at 0, 90, 120, and 180 min from the same data set were compared with the results of standard LHBT. Sixty IBS-D patients and 60 HVs were studied. The genotype in all participants was C/C-13910. LM and LI detection rates increased with lactose dose from 10 g, 20 g to 40 g in both groups (P < 0.001). 4SLHBT showed excellent diagnostic concordance with standard LHBT (97%-100%, Kappa​​ 0.815-0.942) with high sensitivity (90%-100%) and specificity (100%) at all three lactose doses in both groups. Reducing the number of measurements from 13 to 4 samples did not significantly impact on the accuracy of LHBT in health and IBS-D. 4SLHBT is a valid test for assessment of LM and LI in clinical practice.

  9. Non-invasive 13C-glucose breath test using residual gas analyzer-mass spectrometry: a novel tool for screening individuals with pre-diabetes and type 2 diabetes.

    PubMed

    Ghosh, Chiranjit; Maity, Abhijit; Banik, Gourab D; Som, Suman; Chakraborty, Arpita; Selvan, Chitra; Ghosh, Shibendu; Ghosh, Barnali; Chowdhury, Subhankar; Pradhan, Manik

    2014-09-01

    We report, for the first time, the clinical feasibility of a novel residual gas analyzer mass spectrometry (RGA-MS) method for accurate evaluation of the (13)C-glucose breath test ((13)C-GBT) in the diagnosis of pre-diabetes (PD) and type 2 diabetes mellitus (T2D). In T2D or PD, glucose uptake is impaired and results in blunted isotope enriched (13)CO2 production in exhaled breath samples. Using the Receiver operating characteristics (ROC) curve analysis, an optimal diagnostic cut-off point of the (13)CO2/(12)CO2 isotope ratios expressed as the delta-over-baseline (DOB) value, was determined to be δDOB(13)C‰ = 28.81‰ for screening individuals with non-diabetes controls (NDC) and pre-diabetes (PD), corresponding to a sensitivity of 100% and specificity of 94.4%. We also determined another optimal diagnostic cut-off point of δDOB(13)C‰ = 19.88‰ between individuals with PD and T2D, which exhibited 100% sensitivity and 95.5% specificity. Our RGA-MS methodology for the (13)C-GBT also manifested a typical diagnostic positive and negative predictive value of 96% and 100%, respectively. The diagnostic accuracy, precision and validity of the results were also confirmed by high-resolution optical cavity enhanced integrated cavity output spectroscopy (ICOS) measurements. The δDOB(13)C‰ values measured with RGA-MS method, correlated favourably (R(2) = 0.979) with those determined by the laser based ICOS method. Moreover, we observed that the effects of endogenous CO2 production related to basal metabolic rates in individuals were statistically insignificant (p = 0.37 and 0.73) on the diagnostic accuracy. Our findings suggest that the RGA-MS is a valid and sufficiently robust method for the (13)C-GBT which may serve as an alternative non-invasive point-of-care diagnostic tool for routine clinical practices as well as for large-scale diabetes screening purposes in real-time.

  10. Detection of bronchial breathing caused by pneumonia.

    PubMed

    Gross, V; Fachinger, P; Penzel, Th; Koehler, U; von Wichert, P; Vogelmeier, C

    2002-06-01

    The classic auscultation with stethoscope is the established clinical method for the detection of lung diseases. The interpretation of the sounds depends on the experience of the investigating physician. Therefore, a new computer-based method has been developed to classify breath sounds from digital lung sound recordings. Lung sounds of 11 patients with one-sided pneumonia and bronchial breathing were recorded on both the pneumonia side and on contralateral healthy side simultaneously using two microphones. The spectral power for the 300-600 Hz frequency band was computed for four respiratory cycles and normalized. For each breath, the ratio R between the time-segments (duration = 0.1 s) with the highest inspiratory and highest expiratory flow was calculated and averaged. We found significant differences in R between the pneumonia side (R = 1.4 +/- 1.3) and the healthy side (R = 0.5 +/- 0.5; p = 0.003 Wilcoxon-test) of lung. In 218 healthy volunteers we found R = 0.3 +/- 0.2 as a reference-value. The differences of ratio R (delta R) between the pneumonia side and the healthy side (delta R = 1.0 +/- 0.9) were significantly higher compared to follow-up studies after recovery (delta R = 0.0 +/- 0.1, p = 0.005 Wilcoxon-test). The computer based detection of bronchial breathing can be considered useful as part of a quantitative monitoring of patients at risk to develop pneumonia.

  11. Limited electromagnetic interference testing of evidential breath testers

    DOT National Transportation Integrated Search

    1983-05-06

    This report summarizes a limited test program conducted to determine the susceptibility of evidential breath testers (EBTs) to radio frequency interference (RFI). Several comprehensive test protocols were prepared based on procedures developed by the...

  12. 46 CFR 197.450 - Breathing gas tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... taken at the connection point to the distribution system— (1) Every 6 months; and (2) After every repair or modification. (b) Purchased supplies of breathing mixtures supplied to a diver are checked before... commencement of diving operations, at the umbilical or underwater breathing apparatus connection point for the...

  13. Breath carbon stable isotope ratios identify changes in energy balance and substrate utilization in humans.

    PubMed

    Whigham, L D; Butz, D E; Johnson, L K; Schoeller, D A; Abbott, D H; Porter, W P; Cook, M E

    2014-09-01

    Rapid detection of shifts in substrate utilization and energy balance would provide a compelling biofeedback tool for individuals attempting weight loss. As a proof of concept, we tested whether the natural abundance of exhaled carbon stable isotope ratios (breath δ(13)C) reflects shifts between negative and positive energy balance. Volunteers (n=5) consumed a 40% energy-restricted diet for 6 days followed by 50% excess on day 7. Breath was sampled immediately before and 1 h and 2 h after breakfast, lunch and dinner. Exhaled breath δ(13)C values were measured by cavity ring-down spectroscopy. Using repeated measures analysis of variance (ANOVA) followed by Dunnett's contrasts, pre-breakfast breath values on days 2-6 were compared with day 1, and postprandial day 7 time points were compared with pre-breakfast day 7. Energy restriction diminished pre-breakfast breath δ(13)C by day 3 (P<0.05). On day 7, increased energy intake was first detected immediately before dinner (-23.8±0.6 vs -21.9±0.7‰, P=0.002 (means±s.d.)), and breath δ(13)C remained elevated at least 2 h post dinner. In conclusion, when shifting between negative and positive energy balance, breath δ(13)C showed anticipated isotopic changes. Although additional research is needed to determine specificity and repeatability, this method may provide a biomarker for marked increases in caloric intake.

  14. Small intestinal malabsorption in chronic alcoholism: a retrospective study of alcoholic patients by the ¹⁴C-D-xylose breath test.

    PubMed

    Hope, Håvar; Skar, Viggo; Sandstad, Olav; Husebye, Einar; Medhus, Asle W

    2012-04-01

    The ¹⁴C-D-xylose breath test was used at Ullevål University Hospital in the period from 1986 TO 1995 for malabsorption testing. The objective of this retrospective study was to reveal whether patients with chronic alcoholism may have intestinal malabsorption. The consecutive ¹⁴C-D-xylose breath test database was reviewed and patients with the diagnosis of chronic alcoholism were identified. ¹⁴C-D-xylose breath test results of the alcoholic patients were compared with the results of untreated celiac patients and patient and healthy controls. In the ¹⁴C-D-xylose breath test, ¹⁴C-D-xylose was dissolved in water and given orally after overnight fast. Breath samples were taken at 30-min intervals for 210 min, and ¹⁴CO₂ : ¹²CO₂ ratios were calculated for each time point, presenting a time curve for ¹⁴C-D-xylose absorption. Urine was collected after 210 min and the fraction of the total d-xylose passed was calculated (U%). ¹⁴CO₂ in breath and ¹⁴C-D-xylose in urine were analyzed using liquid scintillation. Both breath and urine analysis revealed a pattern of malabsorption in alcoholics comparable with untreated celiac patients, with significantly reduced absorption of d-xylose compared with patient and healthy controls. Alcoholic patients have a significantly reduced ¹⁴C-D-xylose absorption, comparable with untreated celiac patients. This indicates a reduced intestinal function in chronic alcoholism.

  15. Results of the first semi-annual qualification testing of devices to measure breath alcohol

    DOT National Transportation Integrated Search

    1975-01-01

    Eight evidential breath testers were performance tested according to the Standard for Devices to Measure Breath Alcohol Federal Register, Vol 38, No. 212, November 5, 1973. In addition, a prototype breath tester not commercially available was tested....

  16. Ingestion of Casein in a Milk Matrix Modulates Dietary Protein Digestion and Absorption Kinetics but Does Not Modulate Postprandial Muscle Protein Synthesis in Older Men.

    PubMed

    Churchward-Venne, Tyler A; Snijders, Tim; Linkens, Armand M A; Hamer, Henrike M; van Kranenburg, Janneau; van Loon, Luc J C

    2015-07-01

    The slow digestion and amino acid absorption kinetics of isolated micellar casein have been held responsible for its relatively lower postprandial muscle protein synthetic response compared with rapidly digested proteins such as isolated whey. However, casein is normally consumed within a milk matrix. We hypothesized that protein digestion and absorption kinetics and the subsequent muscle protein synthetic response after micellar casein ingestion are modulated by the milk matrix. The aim of this study was to determine the impact of a milk matrix on casein protein digestion and absorption kinetics and postprandial muscle protein synthesis in older men. In a parallel-group design, 32 healthy older men (aged 71 ± 1 y) received a primed continuous infusion of L-[ring-(2)H5]-phenylalanine, L-[ring-3,5-(2)H2]-tyrosine, and L-[1-(13)C]-leucine, and ingested 25 g intrinsically L-[1-(13)C]-phenylalanine and L-[1-(13)C]-leucine labeled casein dissolved in bovine milk serum (Cas+Serum) or water (Cas). Plasma samples and muscle biopsies were collected in the postabsorptive state and for 300 min in the postprandial period to examine whole-body and skeletal muscle protein metabolism. Casein ingestion increased plasma leucine and phenylalanine concentrations and L-[1-(13)C]-phenylalanine enrichments, with a more rapid rise after Cas vs. Cas+Serum. Nonetheless, dietary protein-derived phenylalanine availability did not differ between Cas+Serum (47 ± 2%, mean ± SEM) and Cas (46 ± 3%) when assessed over the 300-min postprandial period (P = 0.80). The milk matrix did not modulate postprandial myofibrillar protein synthesis rates from 0 to 120 min (0.038 ± 0.005 vs. 0.031 ± 0.007%/h) or from 120 to 300 min (0.052 ± 0.004 vs. 0.067 ± 0.005%/h) after Cas+Serum vs. Cas. Similarly, no treatment differences in muscle protein-bound L-[1-(13)C]-phenylalanine enrichments were observed at 120 min (0.003 ± 0.001 vs. 0.002 ± 0.001) or 300 min (0.015 ± 0.002 vs. 0.016 ± 0.002 mole

  17. A Ringdown Breath Analyzer for Diabetes Monitoring: Breath Acetone in Diabetic Patients.

    NASA Astrophysics Data System (ADS)

    Wang, Chuji; Mbi, Armstrong; Shepherd, Mark

    2008-03-01

    It is highly desirable for millions of diabetic patients to have a non-blood, non-invasive, point-of-care device for monitoring daily blood glucose (BG) levels and the adequacy of diabetic treatment and control. Cavity ringdown spectroscopy, due to its unique capability of high sensitivity, fast-response, and relatively low cost for instrumentation, has the potential for medical application through non-invasive analysis of breath biomarkers. We report the first ringdown acetone breath analyzer for clinic testing with diabetic outpatients. The instrument was set in a clinic center and 34 outpatients (24 T1D and 10 T2D) were tested during a four-day period. 10 T1D subjects and 15 nondiabetic persons were tested in our laboratory. Three juvenile-onset T1D subjects were selected for a 24-hr monitoring on the variations of breath acetone and simultaneous BG level. In this talk, we present our research findings including the correlations of breath acetone with BG level and A1C.

  18. Adenosine A1 Receptors in Mouse Pontine Reticular Formation Depress Breathing, Increase Anesthesia Recovery Time, and Decrease Acetylcholine Release

    PubMed Central

    Gettys, George C.; Liu, Fang; Kimlin, Ed; Baghdoyan, Helen A.; Lydic, Ralph

    2012-01-01

    Background Clinical and preclinical data demonstrate the analgesic actions of adenosine. Central administration of adenosine agonists, however, suppresses arousal and breathing by poorly understood mechanisms. This study tested the two-tailed hypothesis that adenosine A1 receptors in the pontine reticular formation (PRF) of C57BL/6J mice modulate breathing, behavioral arousal, and PRF acetylcholine release. Methods Three sets of experiments used 51 mice. First, breathing was measured by plethysmography after PRF microinjection of the adenosine A1 receptor agonist N6-sulfophenyl adenosine (SPA) or saline. Second, mice were anesthetized with isoflurane and time to recovery of righting response (RoRR) was quantified after PRF microinjection of SPA or saline. Third, acetylcholine release in the PRF was measured before and during microdialysis delivery of SPA, the adenosine A1 receptor antagonist 1,3-dipropyl-8-cyclopentylxanthine (DPCPX), or SPA and DPCPX. Results First, SPA significantly decreased respiratory rate (−18%), tidal volume (−12%) and minute ventilation (−16%). Second, SPA concentration accounted for 76% of the variance in RoRR. Third, SPA concentration accounted for a significant amount of the variance in acetylcholine release (52%), RoRR (98%), and breathing rate (86%). DPCPX alone caused a concentration-dependent increase in acetylcholine, decrease in RoRR, and decrease in breathing rate. Coadministration of SPA and DPCPX blocked the SPA-induced decrease in acetylcholine and increase in RoRR. Conclusions Endogenous adenosine acting at adenosine A1 receptors in the PRF modulates breathing, behavioral arousal, and acetylcholine release. The results support the interpretation that an adenosinergic-cholinergic interaction within the PRF comprises one neurochemical mechanism underlying the wakefulness stimulus for breathing. PMID:23263018

  19. Use of the single-breath method of estimating cardiac output during exercise-stress testing.

    NASA Technical Reports Server (NTRS)

    Buderer, M. C.; Rummel, J. A.; Sawin, C. F.; Mauldin, D. G.

    1973-01-01

    The single-breath cardiac output measurement technique of Kim et al. (1966) has been modified for use in obtaining cardiac output measurements during exercise-stress tests on Apollo astronauts. The modifications involve the use of a respiratory mass spectrometer for data acquisition and a digital computer program for data analysis. The variation of the modified method for triplicate steady-state cardiac output measurements was plus or minus 1 liter/min. The combined physiological and methodological variation seen during a set of three exercise tests on a series of subjects was 1 to 2.5 liter/min. Comparison of the modified method with the direct Fick technique showed that although the single-breath values were consistently low, the scatter of data was small and the correlation between the two methods was high. Possible reasons for the low single-breath cardiac output values are discussed.

  20. Establishment of a Quick and Highly Accurate Breath Test for ALDH2 Genotyping

    PubMed Central

    Aoyama, Ikuo; Ohashi, Shinya; Amanuma, Yusuke; Hirohashi, Kenshiro; Mizumoto, Ayaka; Funakoshi, Makiko; Tsurumaki, Mihoko; Nakai, Yukie; Tanaka, Katsuyuki; Hanada, Mariko; Uesaka, Aki; Chiba, Tsutomu; Muto, Manabu

    2017-01-01

    Objectives: Acetaldehyde, the first metabolite of ethanol, is a definite carcinogen for the esophagus, head, and neck; and aldehyde dehydrogenase 2 (ALDH2) is a mitochondrial enzyme that catalyzes the metabolism of acetaldehyde. The ALDH2 genotype exists as ALDH2*1/*1 (active ALDH2), ALDH2*1/*2 (heterozygous inactive ALDH2), and ALDH2*2/*2 (homozygous inactive ALDH2). Many epidemiological studies have reported that ALDH2*2 carriers are at high risk for esophageal or head and neck squamous cell carcinomas by habitual drinking. Therefore, identification of ALDH2*2 carriers would be helpful for the prevention of those cancers, but there have been no methods suitable for mass screening to identify these individuals. Methods: One hundred and eleven healthy volunteers (ALDH2*1/*1 carriers: 53; ALDH2*1/*2 carriers: 48; and ALDH2*2/*2 carriers: 10) were recruited. Breath samples were collected after drinking 100 ml of 0.5% ethanol using specially designed gas bags, and breath ethanol and acetaldehyde levels were measured by semiconductor gas chromatography. Results: The median (range) breath acetaldehyde levels at 1 min after alcohol ingestion were 96.1 (18.1–399.0) parts per billion (p.p.b.) for the ALDH2*1/*1 genotype, 333.5 (78.4–1218.4) p.p.b. for the ALDH2*1/*2 genotype, and 537.1 (213.2–1353.8) p.p.b. for the ALDH2*2/*2 genotype. The breath acetaldehyde levels in ALDH2*2 carriers were significantly higher than for the ALDH2*1/*1 genotype. Notably, the ratio of breath acetaldehyde level-to-breath ethanol level could identify carriers of the ALDH2*2 allele very accurately (whole accuracy; 96.4%). Conclusions: Our novel breath test is a useful tool for identifying ALDH2*2 carriers, who are at high risk for esophageal and head and neck cancers. PMID:28594397

  1. A novel process for recycling and resynthesizing LiNi1/3Co1/3Mn1/3O2 from the cathode scraps intended for lithium-ion batteries.

    PubMed

    Zhang, Xihua; Xie, Yongbing; Cao, Hongbin; Nawaz, Faheem; Zhang, Yi

    2014-09-01

    To solve the recycling challenge for aqueous binder based lithium-ion batteries (LIBs), a novel process for recycling and resynthesizing LiNi1/3Co1/3Mn1/3O2 from the cathode scraps generated during manufacturing process is proposed in this study. Trifluoroacetic acid (TFA) is employed to separate the cathode material from the aluminum foil. The effects of TFA concentration, liquid/solid (L/S) ratio, reaction temperature and time on the separation efficiencies of the cathode material and aluminum foil are investigated systematically. The cathode material can be separated completely under the optimal experimental condition of 15vol.% TFA solution, L/S ratio of 8.0 mL g(-1), reacting at 40°C for 180 min along with appropriate agitation. LiNi1/3Co1/3Mn1/3O2 is successfully resynthesized from the separated cathode material by solid state reaction method. Several kinds of characterizations are performed to verify the typical properties of the resynthesized LiNi1/3Co1/3Mn1/3O2 powder. Electrochemical tests show that the initial charge and discharge capacities of the resynthesized LiNi1/3Co1/3Mn1/3O2 are 201 mAh g(-)(1) and 155.4 mAh g(-1) (2.8-4.5 V, 0.1C), respectively. The discharge capacity remains at 129 mAh g(-1) even after 30 cycles with a capacity retention ratio of 83.01%. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Breath analyzer screening of emergency department patients suspected of alcohol intoxication.

    PubMed

    Sebbane, Mustapha; Claret, Pierre-Géraud; Jreige, Riad; Dumont, Richard; Lefebvre, Sophie; Rubenovitch, Josh; Mercier, Grégoire; Eledjam, Jean-Jacques; de la Coussaye, Jean-Emmanuel

    2012-10-01

    Acute alcohol intoxication is a frequent cause of emergency department (ED) visits. Evaluating a patient's alcohol intoxication is commonly based on both a physical examination and determination of blood alcohol concentration (BAC). To demonstrate the feasibility and usefulness of using a last-generation infrared breath analyzer as a non-invasive and rapid screening tool for alcohol intoxication in the ED. Adult patients suspected of acute alcohol intoxication were prospectively enrolled over 10 days. Breath alcohol concentrations (BrAC) were measured using a handheld infrared breath analyzer. BAC was determined simultaneously by automated enzymatic analysis of a venous blood sample. The relationship between BAC and BrAC values was examined by both linear regression and Bland-Altman analysis. The study included 54 patients (mean age 40±14 years, sex ratio M/F of 3/1). Breath and blood alcohol concentrations ranged from 0 to 1.44 mg/L and from 0 to 4.40 g/L (0-440 mg/dL), respectively. The mean individual BAC/BrAC ratio was 2615±387, 95% confidence interval 2509-2714, which is 30% higher than the legal ratio in France (2000). The correlation between both measurements was excellent: r=0.95 (0.92-0.97). Linear regression revealed BAC=0.026+1.29 (BrAC×2000) and BAC=0.026+0.99 (BrAC×2615). Mean BAC-BrAC differences and limits of agreement were 0.49 g/L [-0.35, 1.34] (or 49 mg/dL [-35, 134] and 0.01 g/L [-0.68, 0.71] (or 1 mg/dL [-68, 71]), for the 2000 and 2615 ratios, respectively. The calculated conversion coefficient provided a satisfactory determination of blood alcohol concentration. Breath alcohol testing, using appropriate BAC/BrAC conversion, different from the legal BAC/BrAC, could be a reliable alternative for routine screening and management of alcohol intoxication in the ED. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Volatile organic compounds as breath biomarkers for active and passive smoking.

    PubMed

    Gordon, Sydney M; Wallace, Lance A; Brinkman, Marielle C; Callahan, Patrick J; Kenny, Donald V

    2002-07-01

    We used real-time breath measurement technology to investigate the suitability of some volatile organic compounds (VOCs) as breath biomarkers for active and passive smoking and to measure actual exposures and resulting breath concentrations for persons exposed to tobacco smoke. Experiments were conducted with five smoker/nonsmoker pairs. The target VOCs included benzene, 1,3-butadiene, and the cigarette smoke biomarker 2,5-dimethylfuran. This study includes what we believe to be the first measurements of 1,3-butadiene in smokers' and nonsmokers' breath. The 1,3-butadiene and 2,5-dimethylfuran peak levels in the smokers' breath were similar (360 and 376 microg/m(3), respectively); the average benzene peak level was 522 microg/m(3). We found higher peak values of the target chemicals and shorter residence times in the body than previously reported, probably because of the improved time resolution made possible by the continuous breath measurement method. The real-time breath analyzer also showed the presence of the chemicals after exposure in the breath of the nonsmokers, but at greatly reduced levels. Single breath samples collected in evacuated canisters and analyzed independently with gas chromatography/mass spectrometry confirmed the presence of the target compounds in the postexposure breath of the nonsmokers but indicated that there was some contamination of the breath analyzer measurements. This was likely caused by desorption of organics from condensed tar in the analyzer tubing and on the quartz fiber filter used to remove particles. We used the decay data from the smokers to estimate residence times for the target chemicals. A two-compartment exponential model generally gave a better fit to the experimental decay data from the smokers than a single-compartment model. Residence times for benzene, 1,3-butadiene, and 2,5-dimethylfuran ranged from 0.5 (1,3-butadiene) to 0.9 min (benzene) for tau1 and were essentially constant (14 min) for tau2. These findings

  4. Prediction of heart transplant rejection with a breath test for markers of oxidative stress.

    PubMed

    Phillips, Michael; Boehmer, John P; Cataneo, Renee N; Cheema, Taseer; Eisen, Howard J; Fallon, John T; Fisher, Peter E; Gass, Alan; Greenberg, Joel; Kobashigawa, Jon; Mancini, Donna; Rayburn, Barry; Zucker, Mark J

    2004-12-15

    The Heart Allograft Rejection: Detection with Breath Alkanes in Low Levels study evaluated a breath test for oxidative stress in heart transplant recipients, and we report here a mathematical model predicting the probability of grade 3 rejection. The breath test divided the heart transplant recipients into 3 groups: positive for grade 3 rejection, negative for grade 3 rejection, and intermediate. The test was 100% sensitive for grade 3 heart transplant rejection when the p value was >/=0.98, and 100% specific when the p value was breath test determined the probability of grade 3 rejection and the predictive value of the result.

  5. Aspiration tests in aqueous foam using a breathing simulator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Archuleta, M.M.

    1995-12-01

    Non-toxic aqueous foams are being developed by Sandia National Laboratories (SNL) for the National Institute of Justice (NIJ) for use in crowd control, cell extractions, and group disturbances in the criminal justice prison systems. The potential for aspiration of aqueous foam during its use and the resulting adverse effects associated with complete immersion in aqueous foam is of major concern to the NIJ when examining the effectiveness and safety of using this technology as a Less-Than-Lethal weapon. This preliminary study was designed to evaluate the maximum quantity of foam that might be aspirated by an individual following total immersion inmore » an SNL-developed aqueous foam. A.T.W. Reed Breathing simulator equipped with a 622 Silverman cam was used to simulate the aspiration of an ammonium laureth sulfate aqueous foam developed by SNL and generated at expansion ratios in the range of 500:1 to 1000:1. Although the natural instinct of an individual immersed in foam is to cover their nose and mouth with a hand or cloth, thus breaking the bubbles and decreasing the potential for aspiration, this study was performed to examine a worst case scenario where mouth breathing only was examined, and no attempt was made to block foam entry into the breathing port. Two breathing rates were examined: one that simulated a sedentary individual with a mean breathing rate of 6.27 breaths/minute, and one that simulated an agitated or heavily breathing individual with a mean breathing rate of 23.7 breaths/minute. The results of this study indicate that, if breathing in aqueous foam without movement, an air pocket forms around the nose and mouth within one minute of immersion.« less

  6. Are Nocturnal Breathing, Sleep, and Cognitive Performance Impaired at Moderate Altitude (1,630-2,590 m)?

    PubMed Central

    Latshang, Tsogyal D.; Lo Cascio, Christian M.; Stöwhas, Anne-Christin; Grimm, Mirjam; Stadelmann, Katrin; Tesler, Noemi; Achermann, Peter; Huber, Reto; Kohler, Malcolm; Bloch, Konrad E.

    2013-01-01

    Study Objectives: Newcomers at high altitude (> 3,000 m) experience periodic breathing, sleep disturbances, and impaired cognitive performance. Whether similar adverse effects occur at lower elevations is uncertain, although numerous lowlanders travel to moderate altitude for professional or recreational activities. We evaluated the hypothesis that nocturnal breathing, sleep, and cognitive performance of lowlanders are impaired at moderate altitude. Design: Randomized crossover trial. Setting: University hospital at 490 m, Swiss mountain villages at 1,630 m and 2,590 m. Participants: Fifty-one healthy men, median (quartiles) age 24 y (20-28 y), living below 800 m. Interventions: Studies at Zurich (490 m) and during 4 consecutive days at 1,630 m and 2,590 m, respectively, 2 days each. The order of altitude exposure was randomized. Polysomnography, psychomotor vigilance tests (PVT), the number back test, several other tests of cognitive performance, and questionnaires were evaluated. Measurements and Results: The median (quartiles) apnea-hypopnea index at 490 m was 4.6/h (2.3; 7.9), values at 1,630 and 2,590 m, day 1 and 2, respectively, were 7.0/h (4.1; 12.6), 5.4/h (3.5; 10.5), 13.1/h (6.7; 32.1), and 8.0/h (4.4; 23.1); corresponding values of mean nocturnal oxygen saturation were 96% (95; 96), 94% (93; 95), 94% (93; 95), 90% (89; 91), 91% (90; 92), P < 0.05 versus 490 m, all instances. Slow wave sleep on the first night at 2,590 m was 21% (18; 25) versus 24% (20; 27) at 490 m (P < 0.05). Psychomotor vigilance and various other measures of cognitive performance did not change significantly. Conclusions: Healthy men acutely exposed during 4 days to hypoxemia at 1,630 m and 2,590 m reveal a considerable amount of periodic breathing and sleep disturbances. However, no significant effects on psychomotor reaction speed or cognitive performance were observed. Clinical Trials Registration: Clinicaltrials.gov: NCT01130948. Citation: Latshang TD; Lo Cascio CM; Stöwhas AC

  7. 21 CFR 862.3050 - Breath-alcohol test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Breath-alcohol test system. 862.3050 Section 862.3050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862...

  8. 21 CFR 862.3050 - Breath-alcohol test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Breath-alcohol test system. 862.3050 Section 862.3050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862...

  9. 21 CFR 862.3050 - Breath-alcohol test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Breath-alcohol test system. 862.3050 Section 862.3050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862...

  10. Prevalence of abnormal lactose breath hydrogen tests in children with functional abdominal pain.

    PubMed

    Garg, Neha; Basu, Srikanta; Singh, Preeti; Kumar, Ruchika; Sharma, Lokesh; Kumar, Praveen

    2017-05-01

    The study was undertaken to determine the prevalence of abnormal lactose breath hydrogen test in children with non-organic chronic abdominal pain. Children with chronic abdominal pain were examined and investigated for organic causes. All children without a known organic cause underwent lactose and glucose breath hydrogen test. After a standard dose of 2 g/kg of lactose to a maximum of 50 g, hydrogen in breath was measured at 15 min intervals for 3 h. A rise of 20 ppm above baseline was considered suggestive of lactose malabsorption. Of 108 children screened, organic causes were found in 46 children. Sixty-two patients without any organic cause underwent hydrogen breath test. Lactose hydrogen breath test (HBT) was positive in 36 of 62 (58%), while 11 (17%) had positive HBT with glucose suggestive of small intestinal bacterial overgrowth (SIBO). Twenty out of 34 (59%) improved on lactose free diet while 8 out of 11 (72%) children of SIBO improved on antibiotics. Lactose malabsorption was seen in 58% of children with non-organic chronic abdominal pain.

  11. Air-Breathing Rocket Engine Test

    NASA Technical Reports Server (NTRS)

    2000-01-01

    This photograph depicts an air-breathing rocket engine that completed an hour or 3,600 seconds of testing at the General Applied Sciences Laboratory in Ronkonkoma, New York. Referred to as ARGO by its design team, the engine is named after the mythological Greek ship that bore Jason and the Argonauts on their epic voyage of discovery. Air-breathing engines, known as rocket based, combined-cycle engines, get their initial take-off power from specially designed rockets, called air-augmented rockets, that boost performance about 15 percent over conventional rockets. When the vehicle's velocity reaches twice the speed of sound, the rockets are turned off and the engine relies totally on oxygen in the atmosphere to burn hydrogen fuel, as opposed to a rocket that must carry its own oxygen, thus reducing weight and flight costs. Once the vehicle has accelerated to about 10 times the speed of sound, the engine converts to a conventional rocket-powered system to propel the craft into orbit or sustain it to suborbital flight speed. NASA's Advanced SpaceTransportation Program at Marshall Space Flight Center, along with several industry partners and collegiate forces, is developing this technology to make space transportation affordable for everyone from business travelers to tourists. The goal is to reduce launch costs from today's price tag of $10,000 per pound to only hundreds of dollars per pound. NASA's series of hypersonic flight demonstrators currently include three air-breathing vehicles: the X-43A, X-43B and X-43C.

  12. Measurement of breath acetone in patients referred for an oral glucose tolerance test.

    PubMed

    Andrews, Brian Terence; Denzer, Wolfgang; Hancock, Gus; Lunn, Dan; Peverall, Robert; Ritchie, Grant; Williams, Karen

    2018-04-12

    Breath acetone concentrations were measured in 141 subjects (aged 19-91 yrs, mean=59.11yrs standard deviation=12.99yrs), male and female, undergoing an oral glucose tolerance test (OGTT), having been referred to clinic on suspicion of type 2 diabetes. Breath samples were measured using an ion-molecule-reaction mass spectrometer, at the commencement of the OGTT, and after 1 and 2hrs. Subjects were asked to observe the normal routine before and during the OGTT, which includes an overnight fast and ingestion of 75g glucose at the beginning of the routine. Several groups of diagnosis were identified: type 2 Diabetes Mellitus positive (T2DM), n=22; impaired glucose intolerance (IGT), n=33; impaired fasting glucose (IFG), n=14; and reactive hypoglycaemia (RHG), n=5. The subjects with no diagnosis (i.e. normoglycaemia) were used as a control group, n=67. Distributions of breath acetone are presented for the different groups. There was no evidence of a direct relationship between blood glucose and acetone measurements at any time during the study (0hr: p=0.4482; 1hr: p=0.6854; and 2hr: p=0.1858). Nor were there significant differences between the measurements of breath acetone for the control group and the T2DM group (0hr: p=0.1759; 1hr: p=0.4521; and 2hr: p=0.7343). However, the ratio of breath acetone at 1hr to the initial breath acetone was found to be significantly different for the T2DM group compared to both the control and IGT groups (p=0.0189 and 0.011, respectively). The T2DM group was also found to be different in terms of ratio of breath acetone after 1hr to that at 2hrs during the OGTT. And was distinctive in that it showed a significant dependence upon the level of blood glucose at 2hrs (p=0.0146). We conclude that single measurements of the concentrations of breath acetone cannot be used as a potential screening diagnostic for T2DM diabetes in this cohort, but monitoring the evolution of breath acetone could open a non-invasive window to aid in the diagnosis

  13. Rescuing cardiac automaticity in L-type Cav1.3 channelopathies and beyond.

    PubMed

    Mesirca, Pietro; Bidaud, Isabelle; Mangoni, Matteo E

    2016-10-15

    Pacemaker activity of the sino-atrial node generates the heart rate. Disease of the sinus node and impairment of atrioventricular conduction induce an excessively low ventricular rate (bradycardia), which cannot meet the needs of the organism. Bradycardia accounts for about half of the total workload of clinical cardiologists. The 'sick sinus' syndrome (SSS) is characterized by sinus bradycardia and periods of intermittent atrial fibrillation. Several genetic or acquired risk factors or pathologies can lead to SSS. Implantation of an electronic pacemaker constitutes the only available therapy for SSS. The incidence of SSS is forecast to double over the next 50 years, with ageing of the general population thus urging the development of complementary or alternative therapeutic strategies. In recent years an increasing number of mutations affecting ion channels involved in sino-atrial automaticity have been reported to underlie inheritable SSS. L-type Ca v 1.3 channels play a major role in the generation and regulation of sino-atrial pacemaker activity and atrioventricular conduction. Mutation in the CACNA1D gene encoding Ca v 1.3 channels induces loss-of-function in channel activity and underlies the sino-atrial node dysfunction and deafness syndrome (SANDD). Mice lacking Ca v 1.3 channels (Ca v 1.3 -/- ) fairly recapitulate SSS and constitute a precious model to test new therapeutic approaches to handle this disease. Work in our laboratory shows that targeting G protein-gated K + (I KACh ) channels effectively rescues SSS of Ca v 1.3 -/- mice. This new concept of 'compensatory' ion channel targeting shines new light on the principles underlying the pacemaker mechanism and may open the way to new therapies for SSS. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.

  14. BreathDx - molecular analysis of exhaled breath as a diagnostic test for ventilator-associated pneumonia: protocol for a European multicentre observational study.

    PubMed

    van Oort, Pouline M P; Nijsen, Tamara; Weda, Hans; Knobel, Hugo; Dark, Paul; Felton, Timothy; Rattray, Nicholas J W; Lawal, Oluwasola; Ahmed, Waqar; Portsmouth, Craig; Sterk, Peter J; Schultz, Marcus J; Zakharkina, Tetyana; Artigas, Antonio; Povoa, Pedro; Martin-Loeches, Ignacio; Fowler, Stephen J; Bos, Lieuwe D J

    2017-01-03

    The diagnosis of ventilator-associated pneumonia (VAP) remains time-consuming and costly, the clinical tools lack specificity and a bedside test to exclude infection in suspected patients is unavailable. Breath contains hundreds to thousands of volatile organic compounds (VOCs) that result from host and microbial metabolism as well as the environment. The present study aims to use breath VOC analysis to develop a model that can discriminate between patients who have positive cultures and who have negative cultures with a high sensitivity. The Molecular Analysis of Exhaled Breath as Diagnostic Test for Ventilator-Associated Pneumonia (BreathDx) study is a multicentre observational study. Breath and bronchial lavage samples will be collected from 100 and 53 intubated and ventilated patients suspected of VAP. Breath will be analysed using Thermal Desorption - Gas Chromatography - Mass Spectrometry (TD-GC-MS). The primary endpoint is the accuracy of cross-validated prediction for positive respiratory cultures in patients that are suspected of VAP, with a sensitivity of at least 99% (high negative predictive value). To our knowledge, BreathDx is the first study powered to investigate whether molecular analysis of breath can be used to classify suspected VAP patients with and without positive microbiological cultures with 99% sensitivity. UKCRN ID number 19086, registered May 2015; as well as registration at www.trialregister.nl under the acronym 'BreathDx' with trial ID number NTR 6114 (retrospectively registered on 28 October 2016).

  15. Application of drug testing using exhaled breath for compliance monitoring of drug addicts in treatment.

    PubMed

    Carlsson, Sten; Olsson, Robert; Lindkvist, Irene; Beck, Olof

    2015-04-01

    Exhaled breath has recently been identified as a possible matrix for drug testing. This study explored the potential of this new method for compliance monitoring of patients being treated for dependence disorders. Outpatients in treatment programs were recruited for this study. Urine was collected as part of clinical routine and a breath sample was collected in parallel together with a questionnaire about their views of the testing procedure. Urine was analyzed for amphetamines, benzodiazepines, cannabis, cocaine, buprenorphine, methadone and opiates using CEDIA immunochemical screening and mass spectrometry confirmation. The exhaled breath was collected using the SensAbues device and analyzed by mass spectrometry for amphetamine, methamphetamine, diazepam, oxazepam, tetrahydrocannabinol, cocaine, benzoylecgonine, buprenorphine, methadone, morphine, codeine and 6-acetylmorphine. A total of 122 cases with parallel urine and breath samples were collected; 34 of these were negative both in urine and breath. Out of 88 cases with positive urine samples 51 (58%) were also positive in breath. Among the patients on methadone treatment, all were positive for methadone in urine and 83% were positive in breath. Among patients in treatment with buprenorphine, 92% were positive in urine and among those 80% were also positive in breath. The questionnaire response documented that in general, patients accepted drug testing well and that the breath sampling procedure was preferred. Compliance testing for the intake of prescribed and unprescribed drugs among patients in treatment for dependence disorders using the exhaled breath sampling technique is a viable method and deserves future attention.

  16. Exhaled breath temperature in children: reproducibility and influencing factors.

    PubMed

    Vermeulen, S; Barreto, M; La Penna, F; Prete, A; Martella, S; Biagiarelli, F; Villa, M P

    2014-09-01

    This study will investigate the reproducibility and influencing factors of exhaled breath temperature measured with the tidal breathing technique in asthmatic patients and healthy children. Exhaled breath temperature, fractional exhaled nitric oxide, and spirometry were assessed in 124 children (63 healthy and 61 asthmatic), aged 11.2 ± 2.5 year, M/F 73/51. A modified version of the American Thoracic Society questionnaire on the child's present and past respiratory history was obtained from parents. Parents were also asked to provide detailed information on their child's medication use during the previous 4 weeks. Ear temperature, ambient temperature, and relative-ambient humidity were also recorded. Exhaled breath temperature measurements were highly reproducible; the second measurement was higher than the first measurement, consistent with a test-retest situation. In 13 subjects, between-session within-day reproducibility of exhaled breath temperature was still high. Exhaled breath temperature increased with age and relative-ambient humidity. Exhaled breath temperature was comparable in healthy and asthmatic children; when adjusted for potential confounders (i.e. ambient conditions and subject characteristics), thermal values of asthmatic patients exceeded those of the healthy children by 1.1 °C. Normalized exhaled breath temperature, by subtracting ambient temperature, was lower in asthmatic patients treated with inhaled corticosteroids than in those who were corticosteroid-naive. Measurements of exhaled breath temperature are highly reproducible, yet influenced by several factors. Corrected values, i.e. normalized exhaled breath temperature, could help us to assess the effect of therapy with inhaled corticosteroids. More studies are needed to improve the usefulness of the exhaled breath temperature measured with the tidal breathing technique in children.

  17. Science Library of Test Items. Volume Nine. Mastery Testing Programme. [Mastery Tests Series 1.] Tests M1-M13.

    ERIC Educational Resources Information Center

    New South Wales Dept. of Education, Sydney (Australia).

    As part of a series of tests to measure mastery of specific skills in the natural sciences, copies of the first 13 tests are provided. Skills to be tested include: (1) reading a table; (2) using a biological key; (3) identifying chemical symbols; (4) identifying parts of a human body; (5) reading a line graph; (6) identifying electronic and…

  18. Test of SensL SiPM coated with NOL-1 wavelength shifter in liquid xenon

    NASA Astrophysics Data System (ADS)

    Akimov, D. Yu.; Belov, V. A.; Borshchev, O. V.; Burenkov, A. A.; Grishkin, Yu. L.; Karelin, A. K.; Kuchenkov, A. V.; Martemiyanov, A. N.; Ponomarenko, S. A.; Simakov, G. E.; Stekhanov, V. N.; Surin, N. M.; Timoshin, V. S.; Zeldovich, O. Ya.

    2017-05-01

    A SensL MicroFC-SMT-60035 6×6 mm2 silicon photo-multiplier coated with a NOL-1 wavelength shifter have been tested in the liquid xenon to detect the 175-nm scintillation light. For comparison, a Hamamatsu vacuum ultraviolet sensitive MPPC VUV3 3×3 mm2 was tested under the same conditions. The photodetection efficiency of 13.1 ± 2.5% and 6.0 ± 1.0%, correspondingly, is obtained.

  19. Statistical Optimization of 1,3-Propanediol (1,3-PD) Production from Crude Glycerol by Considering Four Objectives: 1,3-PD Concentration, Yield, Selectivity, and Productivity.

    PubMed

    Supaporn, Pansuwan; Yeom, Sung Ho

    2018-04-30

    This study investigated the biological conversion of crude glycerol generated from a commercial biodiesel production plant as a by-product to 1,3-propanediol (1,3-PD). Statistical analysis was employed to derive a statistical model for the individual and interactive effects of glycerol, (NH 4 ) 2 SO 4 , trace elements, pH, and cultivation time on the four objectives: 1,3-PD concentration, yield, selectivity, and productivity. Optimum conditions for each objective with its maximum value were predicted by statistical optimization, and experiments under the optimum conditions verified the predictions. In addition, by systematic analysis of the values of four objectives, optimum conditions for 1,3-PD concentration (49.8 g/L initial glycerol, 4.0 g/L of (NH 4 ) 2 SO 4 , 2.0 mL/L of trace element, pH 7.5, and 11.2 h of cultivation time) were determined to be the global optimum culture conditions for 1,3-PD production. Under these conditions, we could achieve high 1,3-PD yield (47.4%), 1,3-PD selectivity (88.8%), and 1,3-PD productivity (2.1/g/L/h) as well as high 1,3-PD concentration (23.6 g/L).

  20. Breath test refusals

    DOT National Transportation Integrated Search

    2007-11-01

    The National Highway Traffic Safety Administration has found that the percentage of people who refuse to provide breath samples when arrested for Driving While Intoxicated (DWI) varies considerably across States, and this creates a concern in the cri...

  1. Detection of Δ9-tetrahydrocannabinol in exhaled breath collected from cannabis users.

    PubMed

    Beck, Olof; Sandqvist, Sören; Dubbelboer, Ilse; Franck, Johan

    2011-10-01

    Exhaled breath has recently been proposed as a new possible matrix for drugs of abuse testing. A key drug is cannabis, and the present study was aimed at investigating the possibility of detecting tetrahydrocannabinol and tetrahydrocannabinol carboxylic acid in exhaled breath after cannabis smoking. Exhaled breath was sampled from 10 regular cannabis users and 8 controls by directing the exhaled breath by suction through an Empore C(18) disk. The disk was extracted with hexane/ethyl acetate, and the resulting extract was evaporated to dryness and redissolved in 100 μL hexane/ethyl acetate. A 3-μL aliquot was injected onto the LC-MS-MS system and analyzed using positive electrospray ionization and selected reaction monitoring. In samples collected 1-12 h after cannabis smoking, tetrahydrocannabinol was detected in all 10 subjects. The rate of excretion was between 9.0 and 77.3 pg/min. Identification of tetrahydrocannabinol was based on correct retention time relative to tetrahydrocannabinol-d(3) and correct product ion ratio. In three samples, peaks were observed for tetrahydrocannabinol carboxylic acid, but these did not fulfill identification criteria. Neither tetrahydrocannabinol or tetrahydrocannabinol carboxylic acid was detected in the controls. These results confirm older reports that tetrahydrocannabinol is present in exhaled breath following cannabis smoking and extend the detection time from minutes to hours. The results further support the idea that exhaled breath is a promising matrix for drugs-of-abuse testing.

  2. 21 CFR 862.3080 - Breath nitric oxide test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Breath nitric oxide test system. 862.3080 Section 862.3080 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test...

  3. 21 CFR 862.3080 - Breath nitric oxide test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Breath nitric oxide test system. 862.3080 Section 862.3080 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test...

  4. 21 CFR 862.3080 - Breath nitric oxide test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Breath nitric oxide test system. 862.3080 Section 862.3080 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test...

  5. 21 CFR 862.3080 - Breath nitric oxide test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Breath nitric oxide test system. 862.3080 Section 862.3080 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test...

  6. Lactulose Breath Test Gas Production in Childhood IBS Is Associated With Intestinal Transit and Bowel Movement Frequency.

    PubMed

    Chumpitazi, Bruno P; Weidler, Erica M; Shulman, Robert J

    2017-04-01

    In adults with irritable bowel syndrome (IBS), bacterial gas production (colonic fermentation) is related to both symptom generation and intestinal transit. Whether gas production affects symptom generation, psychosocial distress, or intestinal transit in childhood IBS is unknown. Children (ages 7-17 years) with pediatric Rome III IBS completed validated psychosocial questionnaires and a 2-week daily diary capturing pain and stooling characteristics. Stool form determined IBS subtype. Subjects then completed a 3-hour lactulose breath test for measurement of total breath hydrogen and methane production. Carmine red was used to determine whole intestinal transit time. A total of 87 children (mean age 13 ± 2.6 [standard deviation] years) were enrolled, of whom 50 (57.5%) were girls. All children produced hydrogen and 51 (58.6%) produced methane. Hydrogen and methane production did not correlate with either abdominal pain frequency/severity or psychosocial distress. Hydrogen and methane production did not differ significantly by IBS subtype. Methane production correlated positively with whole intestinal transit time (r = 0.31, P < 0.005) and inversely with bowel movement frequency (r = -0.245, P < 0.05). Methane production (threshold 3 ppm) as a marker for identifying IBS-C had a sensitivity of 60% and specificity of 42.9%. Lactulose breath test total methane production may serve as a biomarker of whole intestinal transit time and bowel movement frequency in children with IBS. In children with IBS, lactulose breath test hydrogen and methane production did not, however, correlate with abdominal pain, IBS subtype, or psychosocial distress.

  7. 13.1 Foot Diameter Fluted-Core Sandwich Composite Test Article

    NASA Image and Video Library

    2013-09-26

    White light shape and measurement of a 13.1 Foot diameter fluted-core sandwich composite test article designed by LaRC and fabricated by Boeing Under Space Act Agreement SAA1-737, Annex 14. to be tested in LaRC's combined Loads Testing System (COLTS).

  8. 13.1 Foot Diameter Fluted-Core Sandwich Composite Test Article

    NASA Image and Video Library

    2013-09-25

    White light shape and measurement of a 13.1 Foot diameter fluted-core sandwich composite test article designed by LaRC and fabricated by Boeing Under Space Act Agreement SAA1-737, Annex 14. to be tested in LaRC's combined Loads Testing System (COLTS).

  9. Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements.

    PubMed

    Wang, Zhennan; Wang, Chuji

    2013-09-01

    Since the ancient discovery of the 'sweet odor' in human breath gas, pursuits of the breath analysis-based disease diagnostics have never stopped. Actually, the 'smell' of the breath, as one of three key disease diagnostic techniques, has been used in Eastern-Medicine for more than three thousand years. With advancement of measuring technologies in sensitivity and selectivity, more specific breath gas species have been identified and established as a biomarker of a particular disease. Acetone is one of the breath gases and its concentration in exhaled breath can now be determined with high accuracy using various techniques and methods. With the worldwide prevalence of diabetes that is typically diagnosed through blood testing, human desire to achieve non-blood based diabetic diagnostics and monitoring has never been quenched. Questions, such as is breath acetone a biomarker of diabetes and how is the breath acetone related to the blood glucose (BG) level (the golden criterion currently used in clinic for diabetes diagnostic, monitoring, and management), remain to be answered. A majority of current research efforts in breath acetone measurements and its technology developments focus on addressing the first question. The effort to tackle the second question has begun recently. The earliest breath acetone measurement in clearly defined diabetic patients was reported more than 60 years ago. For more than a half-century, as reviewed in this paper, there have been more than 41 independent studies of breath acetone using various techniques and methods, and more than 3211 human subjects, including 1581 healthy people, 242 Type 1 diabetic patients, 384 Type 2 diabetic patients, 174 unspecified diabetic patients, and 830 non-diabetic patients or healthy subjects who are under various physiological conditions, have been used in the studies. The results of the breath acetone measurements collected in this review support that many conditions might cause changes to breath

  10. A Portable Real-Time Ringdown Breath Acetone Analyzer: Toward Potential Diabetic Screening and Management

    PubMed Central

    Jiang, Chenyu; Sun, Meixiu; Wang, Zhennan; Chen, Zhuying; Zhao, Xiaomeng; Yuan, Yuan; Li, Yingxin; Wang, Chuji

    2016-01-01

    Breath analysis has been considered a suitable tool to evaluate diseases of the respiratory system and those that involve metabolic changes, such as diabetes. Breath acetone has long been known as a biomarker for diabetes. However, the results from published data by far have been inconclusive regarding whether breath acetone is a reliable index of diabetic screening. Large variations exist among the results of different studies because there has been no “best-practice method” for breath-acetone measurements as a result of technical problems of sampling and analysis. In this mini-review, we update the current status of our development of a laser-based breath acetone analyzer toward real-time, one-line diabetic screening and a point-of-care instrument for diabetic management. An integrated standalone breath acetone analyzer based on the cavity ringdown spectroscopy technique has been developed. The instrument was validated by using the certificated gas chromatography-mass spectrometry. The linear fittings suggest that the obtained acetone concentrations via both methods are consistent. Breath samples from each individual subject under various conditions in total, 1257 breath samples were taken from 22 Type 1 diabetic (T1D) patients, 312 Type 2 diabetic (T2D) patients, which is one of the largest numbers of T2D subjects ever used in a single study, and 52 non-diabetic healthy subjects. Simultaneous blood glucose (BG) levels were also tested using a standard diabetic management BG meter. The mean breath acetone concentrations were determined to be 4.9 ± 16 ppm (22 T1D), and 1.5 ± 1.3 ppm (312 T2D), which are about 4.5 and 1.4 times of the one in the 42 non-diabetic healthy subjects, 1.1 ± 0.5 ppm, respectively. A preliminary quantitative correlation (R = 0.56, p < 0.05) between the mean individual breath acetone concentration and the mean individual BG levels does exist in 20 T1D subjects with no ketoacidosis. No direct correlation is observed in T1D subjects, T

  11. A Portable Real-Time Ringdown Breath Acetone Analyzer: Toward Potential Diabetic Screening and Management.

    PubMed

    Jiang, Chenyu; Sun, Meixiu; Wang, Zhennan; Chen, Zhuying; Zhao, Xiaomeng; Yuan, Yuan; Li, Yingxin; Wang, Chuji

    2016-07-30

    Breath analysis has been considered a suitable tool to evaluate diseases of the respiratory system and those that involve metabolic changes, such as diabetes. Breath acetone has long been known as a biomarker for diabetes. However, the results from published data by far have been inconclusive regarding whether breath acetone is a reliable index of diabetic screening. Large variations exist among the results of different studies because there has been no "best-practice method" for breath-acetone measurements as a result of technical problems of sampling and analysis. In this mini-review, we update the current status of our development of a laser-based breath acetone analyzer toward real-time, one-line diabetic screening and a point-of-care instrument for diabetic management. An integrated standalone breath acetone analyzer based on the cavity ringdown spectroscopy technique has been developed. The instrument was validated by using the certificated gas chromatography-mass spectrometry. The linear fittings suggest that the obtained acetone concentrations via both methods are consistent. Breath samples from each individual subject under various conditions in total, 1257 breath samples were taken from 22 Type 1 diabetic (T1D) patients, 312 Type 2 diabetic (T2D) patients, which is one of the largest numbers of T2D subjects ever used in a single study, and 52 non-diabetic healthy subjects. Simultaneous blood glucose (BG) levels were also tested using a standard diabetic management BG meter. The mean breath acetone concentrations were determined to be 4.9 ± 16 ppm (22 T1D), and 1.5 ± 1.3 ppm (312 T2D), which are about 4.5 and 1.4 times of the one in the 42 non-diabetic healthy subjects, 1.1 ± 0.5 ppm, respectively. A preliminary quantitative correlation (R = 0.56, p < 0.05) between the mean individual breath acetone concentration and the mean individual BG levels does exist in 20 T1D subjects with no ketoacidosis. No direct correlation is observed in T1D subjects, T2D

  12. Diaphragmatic Breathing Reduces Belching and Proton Pump Inhibitor Refractory Gastroesophageal Reflux Symptoms.

    PubMed

    Ong, Andrew Ming-Liang; Chua, Laura Teng-Teng; Khor, Christopher Jen-Lock; Asokkumar, Ravishankar; S/O Namasivayam, Vikneswaran; Wang, Yu-Tien

    2018-03-01

    In patients with gastroesophageal reflux disease (GERD) and excessive belching, most belches are supragastric, and can induce reflux episodes and worsen GERD. Supragastric belching (SGB) might be reduced with diaphragmatic breathing exercises. We investigated whether diaphragmatic breathing therapy is effective in reducing belching and proton pump inhibitor (PPI)-refractory gastroesophageal reflux symptoms. We performed a prospective study of 36 consecutive patients with GERD refractory to PPI therapy and a belching visual analogue scale (VAS) score of 6 or more, seen at a gastroenterology clinic at a tertiary hospital in Singapore from April 2015 through October 2016. Patients underwent high-resolution manometry and 24-hour pH-impedance studies while they were off PPIs. Fifteen patients were placed on a standardized diaphragmatic breathing exercise protocol (treatment group) and completed questionnaires at baseline, after diaphragmatic breathing therapy, and 4 months after the therapy ended. Twenty-one patients were placed on a waitlist (control subjects), completed the same questionnaires with an additional questionnaire after their waitlist period, and eventually received diaphragmatic breathing therapy. The primary outcome was reduction in belching VAS by 50% or more after treatment. Secondary outcomes included GERD symptoms (evaluated using the reflux disease questionnaire) and quality of life (QoL) scores, determined from the Reflux-Qual Short Form and EuroQoL-VAS. Nine of the 15 patients in the treatment group (60%) and none of the 21 control subjects achieved the primary outcome (P < .001). In the treatment group, the mean belching VAS score decreased from 7.1 ± 1.5 at baseline to 3.5 ± 2.0 after diaphragmatic breathing therapy; in the control group, the mean VAS score was 7.6 ± 1.1 at baseline and 7.4 ± 1.3 after the waitlist period. Eighty percent of patients in the treatment group significantly reduced belching frequency compared with 19% in control

  13. eAMI: A Qualitative Quantification of Periodic Breathing Based on Amplitude of Oscillations

    PubMed Central

    Fernandez Tellez, Helio; Pattyn, Nathalie; Mairesse, Olivier; Dolenc-Groselj, Leja; Eiken, Ola; Mekjavic, Igor B.; Migeotte, P. F.; Macdonald-Nethercott, Eoin; Meeusen, Romain; Neyt, Xavier

    2015-01-01

    Study Objectives: Periodic breathing is sleep disordered breathing characterized by instability in the respiratory pattern that exhibits an oscillatory behavior. Periodic breathing is associated with increased mortality, and it is observed in a variety of situations, such as acute hypoxia, chronic heart failure, and damage to respiratory centers. The standard quantification for the diagnosis of sleep related breathing disorders is the apnea-hypopnea index (AHI), which measures the proportion of apneic/hypopneic events during polysomnography. Determining the AHI is labor-intensive and requires the simultaneous recording of airflow and oxygen saturation. In this paper, we propose an automated, simple, and novel methodology for the detection and qualification of periodic breathing: the estimated amplitude modulation index (eAMI). Patients or Participants: Antarctic cohort (3,800 meters): 13 normal individuals. Clinical cohort: 39 different patients suffering from diverse sleep-related pathologies. Measurements and Results: When tested in a population with high levels of periodic breathing (Antarctic cohort), eAMI was closely correlated with AHI (r = 0.95, P < 0.001). When tested in the clinical setting, the proposed method was able to detect portions of the signal in which subclinical periodic breathing was validated by an expert (n = 93; accuracy = 0.85). Average eAMI was also correlated with the loop gain for the combined clinical and Antarctica cohorts (r = 0.58, P < 0.001). Conclusions: In terms of quantification and temporal resolution, the eAMI is able to estimate the strength of periodic breathing and the underlying loop gain at any given time within a record. The impaired prognosis associated with periodic breathing makes its automated detection and early diagnosis of clinical relevance. Citation: Fernandez Tellez H, Pattyn N, Mairesse O, Dolenc-Groselj L, Eiken O, Mekjavic IB, Migeotte PF, Macdonald-Nethercott E, Meeusen R, Neyt X. eAMI: a qualitative

  14. Comparison of an increased waist circumference with a positive hydrogen breath test as a clinical predictor of lactose intolerance.

    PubMed

    Zapata-Castilleja, Carlos A; Montes-Tapia, Fernando F; Treviño-Garza, Consuelo; Martínez-Cobos, María C; García-Cantú, Jesús; Arenas-Fabbri, Vincenzo; de la O-Escamilla, Norma; de la O-Cavazos, Manuel

    2017-04-01

    Lactose intolerance is a common disease in pediatrics, and its wrong diagnosis will lead to morbidity. The primary objective of this study was to assess the usefulness of an increased waist circumference during the hydrogen breath test as a predictor of lactose intolerance. The secondary objective was to analyze the impact of body mass index, waist circumference measurement, and age on the abdominal distension of patients with lactose intolerance. A total of 138 subjects aged 3 to 15 years were included. They underwent serial measurements of the waist circumference and hydrogen levels in the breath every 30 minutes over 3 hours during the hydrogen breath test. Out of the entire sample, 35 (25.4%) patients had lactose intolerance. An increase of 0.85 cm in waist circumference compared to the baseline waist circumference results in a sensitivity of 88% and a specificity of 85% to predict lactose intolerance (odds ratio: 42.14, 95% confidence interval: 13.08-135.75, p ≤ 0.001). The body mass index and waist circumference measurement did not affect abdominal distension (p= not significant); however, age modified the time of distension. A 0.85 cm increase in waist circumference compared to the baseline waist circumference during the hydrogen breath test is a useful parameter for the diagnosis of lactose intolerance in pediatrics. Variations in relation to body mass index and waist circumference did not affect the usefulness of an increased waist circumference, unlike age.

  15. Bat breath reveals metabolic substrate use in free-ranging vampires.

    PubMed

    Voigt, Christian C; Grasse, Patricia; Rex, Katja; Hetz, Stefan K; Speakman, John R

    2008-01-01

    We analysed the stable carbon isotope ratio in exhaled CO(2) (delta(13)C(breath)) of free-ranging vampires to assess the type of metabolized substrate (endogenous or exogenous substrate) and its origin, i.e. whether the carbon atoms came from a C(4) food web (grass and cattle) or the C(3) food web in which they were captured (a rainforest remnant and its mammals). For an improved understanding of factors influencing the delta(13)C(breath) of vampires, we conducted feeding experiments with captive animals. The mean delta(13)C(breath) of starved bats was depleted in (13)C in relation to the diet by 4.6 per thousand (n = 10). Once fed with blood, delta(13)C(breath )levelled off within a short time approximately 2.2 per thousand above the stable carbon isotope signature of the diet. The median time required to exchange 50% of the carbon atoms in exhaled CO(2) with carbon atoms from the ingested blood was 18.6 min (mean 29.5 +/- 19.0 min, n = 5). The average delta(13)C of wing membrane and fur in free-ranging vampire bats suggested that bats almost exclusively foraged for cattle blood during the past weeks. The delta(13)C(breath) of the same bats averaged -19.1 per thousand. Given that all free-ranging vampires were starving and that the delta(13)C of cattle was more in enriched in (13)C by 5-6 per thousand than the delta(13)C(breath) of vampires, we conclude that the vampire bats of our study metabolised fat that was predominantly built from carbon atoms originating from cattle blood. Since delta(13)C of wing membrane and fur integrates over weeks and months respectively and delta(13)C(breath) over hours and days, we also conclude that vampire bats of the studied population consistently ignored rainforest mammals and chose cattle as their prey during and prior to our study.

  16. Fecal /sup 13/C analysis for the detection and quantitation of intestinal malabsorption

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klein, P.D.; MacLean, W.C. Jr.; Watkins, J.B.

    Use of /sup 14/CO/sub 2/ breath tests and fecal analyses for the detection and quantitation of intestinal malabsorption has been extensively documented in adult subjects. The use of radioisotopes has extended the range of breath test applications to include pediatric and geriatric subjects. Here we report a fecal /sup 13/C analysis that can be used in conjunction with /sup 14/CO/sub 2/ breath tests. Twenty-four-hour fecal samples were collected before and after the administration of a labeled substrate. Simultaneous cholyglycine /sup 13/CO/sub 2/ breath tests and fecal assays were performed in five children. One child with bacterial overgrowth had an abnormalmore » breath test and a normal fecal test. Of three children with ileal dysfunction, only one had an abnormal breath test, whereas the fecal test was abnormal in all three. Both the breath test and fecal test were abnormal for a child who had undergone an ileal resection. Both tests were normal for a child with ulcerative colitis.« less

  17. Chemical Analysis of Exhaled Human Breath Using High Resolution Mm-Wave Rotational Spectra

    NASA Astrophysics Data System (ADS)

    Guo, Tianle; Branco, Daniela; Thomas, Jessica; Medvedev, Ivan; Dolson, David; Nam, Hyun-Joo; O, Kenneth

    2014-06-01

    High resolution rotational spectroscopy enables chemical sensors that are both sensitive and highly specific, which is well suited for analysis of expired human breath. We have previously reported on detection of breath ethanol, methanol, acetone, and acetaldehyde using THz sensors. This paper will outline our present efforts in this area, with specific focus on our ongoing quest to correlate levels of blood glucose with concentrations of a few breath chemicals known to be affected by elevated blood sugar levels. Prospects, challenges and future plans will be outlined and discussed. Fosnight, A.M., B.L. Moran, and I.R. Medvedev, Chemical analysis of exhaled human breath using a terahertz spectroscopic approach. Applied Physics Letters, 2013. 103(13): p. 133703-5.

  18. Effects of breathing pattern and inspired air conditions on breath condensate volume, pH, nitrite, and protein concentrations.

    PubMed

    McCafferty, J B; Bradshaw, T A; Tate, S; Greening, A P; Innes, J A

    2004-08-01

    The effects of breathing pattern and inspired air conditions on the volume and content of exhaled breath condensate (EBC) were investigated. Total exhaled water (TEW), EBC volume, pH, nitrite and protein concentrations were measured in three groups of 10 healthy subjects breathing into a condenser at different target minute ventilations (Vm), tidal volumes (Vt), and inspired air conditions. The volumes of both TEW and EBC increased significantly with Vm. For Vm 7.5, 15 and 22.5 l/min, mean (SD) EBC was 627 (258) microl, 1019 (313) microl, and 1358 (364) microl, respectively (p<0.001) and TEW was 1879 (378) microl, 2986 (496) microl, and 4679 (700) microl, respectively (p<0.001). TEW was significantly higher than EBC, reflecting a condenser efficiency of 40% at a target Vm of 7.5 l/min which reduced to 29% at Vm 22.5 l/min. Lower Vt gave less TEW than higher Vt (26.6 v 30.7 microl/l, mean difference 4.1 (95% CI 2.6 to 5.6), p<0.001) and a smaller EBC volume (4.3 v 7.6 microl/l, mean difference 3.4 (95% CI 2.3 to 4.5), p<0.001). Cooler and drier inspired air yielded less water vapour and less breath condensate than standard conditions (p<0.05). Changes in the breathing pattern had no effect on EBC protein and nitrite concentrations and pH. These results show that condensate volume can be increased by using high Vt and increased Vm without compromising the dilution of the sample.

  19. A novel process for recycling and resynthesizing LiNi{sub 1/3}Co{sub 1/3}Mn{sub 1/3}O{sub 2} from the cathode scraps intended for lithium-ion batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Xihua; Key Laboratory of Green Process and Engineering, Institute of Process Engineering, Chinese Academy of Sciences, Beijing 100190; Beijing Engineering Research Center of Process Pollution Control, Beijing 100190

    Highlights: • A simple process to recycle cathode scraps intended for lithium-ion batteries. • Complete separation of the cathode material from the aluminum foil is achieved. • The recovered aluminum foil is highly pure. • LiNi{sub 1/3}Co{sub 1/3}Mn{sub 1/3}O{sub 2} is directly resynthesized from the separated cathode material. - Abstract: To solve the recycling challenge for aqueous binder based lithium-ion batteries (LIBs), a novel process for recycling and resynthesizing LiNi{sub 1/3}Co{sub 1/3}Mn{sub 1/3}O{sub 2} from the cathode scraps generated during manufacturing process is proposed in this study. Trifluoroacetic acid (TFA) is employed to separate the cathode material from the aluminummore » foil. The effects of TFA concentration, liquid/solid (L/S) ratio, reaction temperature and time on the separation efficiencies of the cathode material and aluminum foil are investigated systematically. The cathode material can be separated completely under the optimal experimental condition of 15 vol.% TFA solution, L/S ratio of 8.0 mL g{sup −1}, reacting at 40 °C for 180 min along with appropriate agitation. LiNi{sub 1/3}Co{sub 1/3}Mn{sub 1/3}O{sub 2} is successfully resynthesized from the separated cathode material by solid state reaction method. Several kinds of characterizations are performed to verify the typical properties of the resynthesized LiNi{sub 1/3}Co{sub 1/3}Mn{sub 1/3}O{sub 2} powder. Electrochemical tests show that the initial charge and discharge capacities of the resynthesized LiNi{sub 1/3}Co{sub 1/3}Mn{sub 1/3}O{sub 2} are 201 mAh g{sup −1} and 155.4 mAh g{sup −1} (2.8–4.5 V, 0.1 C), respectively. The discharge capacity remains at 129 mAh g{sup −1} even after 30 cycles with a capacity retention ratio of 83.01%.« less

  20. In vitro optimization of non-small cell lung cancer activity with troxacitabine, L-1,3-dioxolane-cytidine, prodrugs.

    PubMed

    Radi, Marco; Adema, Auke D; Daft, Jonathan R; Cho, Jong H; Hoebe, Eveline K; Alexander, Lou-Ella M M; Peters, Godefridus J; Chu, Chung K

    2007-05-03

    l-1,3-Dioxolane-cytidine, a potent anticancer agent against leukemia, has limited efficacy against solid tumors, perhaps due to its hydrophilicity. Herein, a library of prodrugs were synthesized to optimize in vitro antitumor activity against non-small cell lung cancer. N4-Substituted fatty acid amide prodrugs of 10-16 carbon chain length demonstrated significantly improved antitumor activity over l-1,3-dioxolane-cytidine. These in vitro results suggest that the in vivo therapeutic efficacy of l-1,3-dioxolane-cytidine against solid tumors may be improved with prodrug strategies.

  1. Breath Test Refusals and Their Effect on DWI Prosecution

    DOT National Transportation Integrated Search

    2012-07-01

    This report describes the design and results of a project aimed at estimating the rate that drivers : refuse to submit to a legally-requested breath alcohol concentration test, and the effect of such : refusals on the prosecution of DWI cases. The st...

  2. Correlations between the circadian patterns of body temperature, metabolism and breathing in rats.

    PubMed

    Mortola, Jacopo P

    2007-02-15

    It had been demonstrated previously that the circadian patterns of activity and state of arousal are not essential for the manifestation of the daily patterns of pulmonary ventilation (V(E)), tidal volume (V(T)) and breathing frequency (f). In this study we investigated the extent of the linkage between the circadian pattern of breathing and those of body temperature (T(b)) and metabolic rate (oxygen consumption, V(O2), and carbon dioxide production, V(CO2)). Rats were instrumented for measurements of T(b) (by telemetry), and placed in a chamber for continuous 13-day period of measurement of breathing (by a modification of the barometric methodology), and of V(O2) and V(CO2) (by an open flow method). After the first 4 days in control conditions under a 12 h light:12 h dark (L:D) cycle, a perturbation was introduced on day 4, with an L-phase prolongation of 12 h, and on day 9, with an D-phase prolongation of 12 h. During the control days 1-4, all variables had daily oscillations (higher values in D), in phase with each other. During the perturbations (days 4-13), changes in T(b), V(O2) and V(CO2), averaged over the whole period, correlated significantly better with f than with V(T). Day-by-day X-Y loops indicated that V (E), V(T) and f could lead significantly the changes of T(b), V(O2) and V(CO2), and that these relations changed throughout the perturbation period. In addition, f and V(T) did not change necessarily in phase with each other. It is concluded that neither the oscillation in T(b) nor that in metabolism can be considered the direct cause of the daily oscillation of breathing. Presumably, the circadian pattern of breathing reflects the interplay of the daily patterns of many variables, none acting as the primary guide of the breathing daily rhythm.

  3. A better state-of-mind: deep breathing reduces state anxiety and enhances test performance through regulating test cognitions in children.

    PubMed

    Khng, Kiat Hui

    2017-11-01

    A pre-test/post-test, intervention-versus-control experimental design was used to examine the effects, mechanisms and moderators of deep breathing on state anxiety and test performance in 122 Primary 5 students. Taking deep breaths before a timed math test significantly reduced self-reported feelings of anxiety and improved test performance. There was a statistical trend towards greater effectiveness in reducing state anxiety for boys compared to girls, and in enhancing test performance for students with higher autonomic reactivity in test-like situations. The latter moderation was significant when comparing high-versus-low autonomic reactivity groups. Mediation analyses suggest that deep breathing reduces state anxiety in test-like situations, creating a better state-of-mind by enhancing the regulation of adaptive-maladaptive thoughts during the test, allowing for better performance. The quick and simple technique can be easily learnt and effectively applied by most children to immediately alleviate some of the adverse effects of test anxiety on psychological well-being and academic performance.

  4. Spontaneous breathing test in the prediction of extubation failure in the pediatric population.

    PubMed

    Nascimento, Milena Siciliano; Rebello, Celso Moura; Vale, Luciana Assis Pires Andrade; Santos, Érica; Prado, Cristiane do

    2017-01-01

    To assess whether the spontaneous breathing test can predict the extubation failure in pediatric population. A prospective and observational study that evaluated data of inpatients at the Pediatric Intensive Care Unit between May 2011 and August 2013, receiving mechanical ventilation for at least 24 hours followed by extubation. The patients were classified in two groups: Test Group, with patients extubated after spontaneous breathing test, and Control Group, with patients extubated without spontaneous breathing test. A total of 95 children were enrolled in the study, 71 in the Test Group and 24 in the Control Group. A direct comparison was made between the two groups regarding sex, age, mechanical ventilation time, indication to start mechanical ventilation and respiratory parameters before extubation in the Control Group, and before the spontaneous breathing test in the Test Group. There was no difference between the parameters evaluated. According to the analysis of probability of extubation failure between the two groups, the likelihood of extubation failure in the Control Group was 1,412 higher than in the Test Group, nevertheless, this range did not reach significance (p=0.706). This model was considered well-adjusted according to the Hosmer-Lemeshow test (p=0.758). The spontaneous breathing test was not able to predict the extubation failure in pediatric population. Avaliar se o teste de respiração espontânea pode ser utilizado para predizer falha da extubação na população pediátrica. Estudo prospectivo, observacional, no qual foram avaliados todos os pacientes internados no Centro de Terapia Intensiva Pediátrica, no período de maio de 2011 a agosto de 2013, que utilizaram ventilação mecânica por mais de 24 horas e que foram extubados. Os pacientes foram classificados em dois grupos: Grupo Teste, que incluiu os pacientes extubados depois do teste de respiração espontânea; e Grupo Controle, pacientes foram sem teste de respiração espont

  5. Breathing metabolic simulator

    NASA Technical Reports Server (NTRS)

    Bartlett, R. G.; Hendricks, C. M.; Morison, W. B.

    1972-01-01

    The development of a breathing metabolic simulator (BMS) is reported. This BMS simulates all of the breathing and metabolic parameters required for complete evaluation and test of life support and resuscitation equipment. It is also useful for calibrating and validating mechanical and gaseous pulmonary function test procedures. Breathing rate, breathing depth, breath velocity contour, oxygen uptake, and carbon dioxide release are all variable over wide ranges simulating conditions from sleep to hard work with respiratory exchange ratios covering the range from hypoventilation. In addition, all of these parameters are remotely controllable to facilitate use of the device in hostile or remote environments. The exhaled breath is also maintained at body temperature and a high humidity. The simulation is accurate to the extent of having a variable functional residual capacity independent of other parameters.

  6. Lactobacillus casei Ferments the N-Acetylglucosamine Moiety of Fucosyl-α-1,3-N-Acetylglucosamine and Excretes l-Fucose

    PubMed Central

    Rodríguez-Díaz, Jesús; Rubio-del-Campo, Antonio

    2012-01-01

    We have previously characterized from Lactobacillus casei BL23 three α-l-fucosidases, AlfA, AlfB, and AlfC, which hydrolyze in vitro natural fucosyl-oligosaccharides. In this work, we have shown that L. casei is able to grow in the presence of fucosyl-α-1,3-N-acetylglucosamine (Fuc-α-1,3-GlcNAc) as a carbon source. Interestingly, L. casei excretes the l-fucose moiety during growth on Fuc-α-1,3-GlcNAc, indicating that only the N-acetylglucosamine moiety is being metabolized. Analysis of the genomic sequence of L. casei BL23 shows that downstream from alfB, which encodes the α-l-fucosidase AlfB, a gene, alfR, that encodes a transcriptional regulator is present. Divergently from alfB, three genes, alfEFG, that encode proteins with homology to the enzyme IIAB (EIIAB), EIIC, and EIID components of a mannose-class phosphoenolpyruvate:sugar phosphotransferase system (PTS) are present. Inactivation of either alfB or alfF abolishes the growth of L. casei on Fuc-α-1,3-GlcNAc. This proves that AlfB is involved in Fuc-α-1,3-GlcNAc metabolism and that the transporter encoded by alfEFG participates in the uptake of this disaccharide. A mutation in the PTS general component enzyme I does not eliminate the utilization of Fuc-α-1,3-GlcNAc, suggesting that the transport via the PTS encoded by alfEFG is not coupled to phosphorylation of the disaccharide. Transcriptional analysis with alfR and ccpA mutants shows that the two gene clusters alfBR and alfEFG are regulated by substrate-specific induction mediated by the inactivation of the transcriptional repressor AlfR and by carbon catabolite repression mediated by the catabolite control protein A (CcpA). This work reports for the first time the characterization of the physiological role of an α-l-fucosidase in lactic acid bacteria and the utilization of Fuc-α-1,3-GlcNAc as a carbon source for bacteria. PMID:22544237

  7. Tidal volume single breath washout of two tracer gases--a practical and promising lung function test.

    PubMed

    Singer, Florian; Stern, Georgette; Thamrin, Cindy; Fuchs, Oliver; Riedel, Thomas; Gustafsson, Per; Frey, Urs; Latzin, Philipp

    2011-03-10

    Small airway disease frequently occurs in chronic lung diseases and may cause ventilation inhomogeneity (VI), which can be assessed by washout tests of inert tracer gas. Using two tracer gases with unequal molar mass (MM) and diffusivity increases specificity for VI in different lung zones. Currently washout tests are underutilised due to the time and effort required for measurements. The aim of this study was to develop and validate a simple technique for a new tidal single breath washout test (SBW) of sulfur hexafluoride (SF(6)) and helium (He) using an ultrasonic flowmeter (USFM). The tracer gas mixture contained 5% SF(6) and 26.3% He, had similar total MM as air, and was applied for a single tidal breath in 13 healthy adults. The USFM measured MM, which was then plotted against expired volume. USFM and mass spectrometer signals were compared in six subjects performing three SBW. Repeatability and reproducibility of SBW, i.e., area under the MM curve (AUC), were determined in seven subjects performing three SBW 24 hours apart. USFM reliably measured MM during all SBW tests (n = 60). MM from USFM reflected SF(6) and He washout patterns measured by mass spectrometer. USFM signals were highly associated with mass spectrometer signals, e.g., for MM, linear regression r-squared was 0.98. Intra-subject coefficient of variation of AUC was 6.8%, and coefficient of repeatability was 11.8%. The USFM accurately measured relative changes in SF(6) and He washout. SBW tests were repeatable and reproducible in healthy adults. We have developed a fast, reliable, and straightforward USFM based SBW method, which provides valid information on SF(6) and He washout patterns during tidal breathing.

  8. Tidal Volume Single Breath Washout of Two Tracer Gases - A Practical and Promising Lung Function Test

    PubMed Central

    Singer, Florian; Stern, Georgette; Thamrin, Cindy; Fuchs, Oliver; Riedel, Thomas; Gustafsson, Per; Frey, Urs; Latzin, Philipp

    2011-01-01

    Background Small airway disease frequently occurs in chronic lung diseases and may cause ventilation inhomogeneity (VI), which can be assessed by washout tests of inert tracer gas. Using two tracer gases with unequal molar mass (MM) and diffusivity increases specificity for VI in different lung zones. Currently washout tests are underutilised due to the time and effort required for measurements. The aim of this study was to develop and validate a simple technique for a new tidal single breath washout test (SBW) of sulfur hexafluoride (SF6) and helium (He) using an ultrasonic flowmeter (USFM). Methods The tracer gas mixture contained 5% SF6 and 26.3% He, had similar total MM as air, and was applied for a single tidal breath in 13 healthy adults. The USFM measured MM, which was then plotted against expired volume. USFM and mass spectrometer signals were compared in six subjects performing three SBW. Repeatability and reproducibility of SBW, i.e., area under the MM curve (AUC), were determined in seven subjects performing three SBW 24 hours apart. Results USFM reliably measured MM during all SBW tests (n = 60). MM from USFM reflected SF6 and He washout patterns measured by mass spectrometer. USFM signals were highly associated with mass spectrometer signals, e.g., for MM, linear regression r-squared was 0.98. Intra-subject coefficient of variation of AUC was 6.8%, and coefficient of repeatability was 11.8%. Conclusion The USFM accurately measured relative changes in SF6 and He washout. SBW tests were repeatable and reproducible in healthy adults. We have developed a fast, reliable, and straightforward USFM based SBW method, which provides valid information on SF6 and He washout patterns during tidal breathing. PMID:21423739

  9. Rapid Point-Of-Care Breath Test for Biomarkers of Breast Cancer and Abnormal Mammograms

    PubMed Central

    Phillips, Michael; Beatty, J. David; Cataneo, Renee N.; Huston, Jan; Kaplan, Peter D.; Lalisang, Roy I.; Lambin, Philippe; Lobbes, Marc B. I.; Mundada, Mayur; Pappas, Nadine; Patel, Urvish

    2014-01-01

    Background Previous studies have reported volatile organic compounds (VOCs) in breath as biomarkers of breast cancer and abnormal mammograms, apparently resulting from increased oxidative stress and cytochrome p450 induction. We evaluated a six-minute point-of-care breath test for VOC biomarkers in women screened for breast cancer at centers in the USA and the Netherlands. Methods 244 women had a screening mammogram (93/37 normal/abnormal) or a breast biopsy (cancer/no cancer 35/79). A mobile point-of-care system collected and concentrated breath and air VOCs for analysis with gas chromatography and surface acoustic wave detection. Chromatograms were segmented into a time series of alveolar gradients (breath minus room air). Segmental alveolar gradients were ranked as candidate biomarkers by C-statistic value (area under curve [AUC] of receiver operating characteristic [ROC] curve). Multivariate predictive algorithms were constructed employing significant biomarkers identified with multiple Monte Carlo simulations and cross validated with a leave-one-out (LOO) procedure. Results Performance of breath biomarker algorithms was determined in three groups: breast cancer on biopsy versus normal screening mammograms (81.8% sensitivity, 70.0% specificity, accuracy 79% (73% on LOO) [C-statistic value], negative predictive value 99.9%); normal versus abnormal screening mammograms (86.5% sensitivity, 66.7% specificity, accuracy 83%, 62% on LOO); and cancer versus no cancer on breast biopsy (75.8% sensitivity, 74.0% specificity, accuracy 78%, 67% on LOO). Conclusions A pilot study of a six-minute point-of-care breath test for volatile biomarkers accurately identified women with breast cancer and with abnormal mammograms. Breath testing could potentially reduce the number of needless mammograms without loss of diagnostic sensitivity. PMID:24599224

  10. Three-Hour Dives with Exercise While Breathing Oxygen Partial Pressure of 1.3 ATM

    DTIC Science & Technology

    2007-10-01

    after the breath hold. Adjustments were made for carboxyhemoglobin and hemoglobin concentrations,9 and the samples were chosen to ensure that the...CO and 0.3% methane. A CO oximeter (Instrumentation Laboratory; Lexington, MA) determined the pretest carboxyhemoglobin and hemoglobin concentrations

  11. Gastric emptying and related symptoms in patients treated with buspirone, amitriptyline or clebopride: a "real world" study by 13C-octanoic Acid Breath Test.

    PubMed

    Caviglia, Gian P; Sguazzini, Carlo; Cisarò, Fabio; Ribaldone, Davide G; Rosso, Chiara; Fagoonee, Sharmila; Smedile, Antonina; Saracco, Giorgio M; Astegiano, Marco; Pellicano, Rinaldo

    2017-12-01

    Gastric motility is a key-factor in the pathogenesis of functional dyspepsia (FD). 13C-octanoic Acid Breath Test (OBT) is a tool used for measuring gastric emptying time in clinical setting. We aimed to investigate the variation in FD symptoms and OBT parameters after treatment with buspirone, amitriptyline or clebopride. Between Jan-2007 and Dec-2014, we enrolled 59 patients with FD unresponsive to first-line therapy with proton pump inhibitors and/or domperidone that underwent OBT before and after 3 months of buspirone (N.=32), amitriptyline (N.=16) or clebopride (N.=11) treatment. Early satiation severity was positively correlated with gastric half emptying time (t1/2) (r=0.3789, P=0.003) and gastric lag phase (r=0.3371, P=0.011), and negatively correlated with gastric emptying coefficient (r=-0.3231, P=0.015). A reduction in t1/2 measurement in association to postprandial fullness, and early satiation severity improvement was observed (P=0.009, P=0.005 and P<0.001, respectively). Patients treated with buspirone obtained both a decrease in t1/2 (P=0.005) and an amelioration in early satiation (P=0.001). Patients under amitriptyline treatment experienced an improvement in postprandial fullness (P=0.046), whereas no variation was reported in patients treated with clebopride. Patients with FD, non-responders to first-line therapy and reporting meal-related discomfort, may benefit from buspirone or amitriptyline-based therapies.

  12. Breath alcohol analyzer mistakes methanol poisoning for alcohol intoxication.

    PubMed

    Caravati, E Martin; Anderson, Kathleen T

    2010-02-01

    Breath alcohol analyzers are used to detect ethanol in motorists and others suspected of public intoxication. One concern is their ability to detect interfering substances that may falsely increase the ethanol reading. A 47-year-old-man was found in a public park, acting intoxicated. A breath analyzer test (Intoxilyzer 5000EN) measured 0.288 g/210 L breath ethanol, without an interferent noted. In the emergency department, the patient admitted to drinking HEET Gas-Line antifreeze, which contains 99% methanol. Two to three hours after ingestion, serum and urine toxicology screen results were negative for ethanol and multiple other substances. His serum methanol concentration was 589 mg/dL, serum osmolality 503 mOsm/kg, osmolar gap 193 mOsm/kg, and anion gap 17 mmol/L. The patient was treated with intravenous ethanol, fomepizole, and hemodialysis without complication. This is a unique clinical case of a breath alcohol analyzer reporting methanol as ethanol. Intoxilyzer devices have been shown to indicate some substances (acetone) as interferents in humans but not methanol. Increased serum concentrations of methanol can be reported as ethanol by a commonly used breath alcohol analyzer, which can result in a delayed diagnosis or misdiagnosis and subsequent methanol toxicity if antidotal treatment is not administered in a timely manner. Copyright (c) 2009 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.

  13. A study of characteristics of a reliable and practical breath alcohol screening test. Part A

    DOT National Transportation Integrated Search

    1975-08-01

    The objectives of this study were (1) to investigate several commercially available breath-alcohol screening test devices of the length-of-stain type, under standardized laboratory conditions, with respect to their ability satisfactorily to detect an...

  14. The Contribution of L-Type Cav1.3 Channels to Retinal Light Responses

    PubMed Central

    Shi, Liheng; Chang, Janet Ya-An; Yu, Fei; Ko, Michael L.; Ko, Gladys Y.-P.

    2017-01-01

    L-type voltage-gated calcium channels (LTCCs) regulate tonic neurotransmitter release from sensory neurons including retinal photoreceptors. There are three types of LTCCs (Cav1.2, Cav1.3, and Cav1.4) expressed in the retina. While Cav1.2 is expressed in all retinal cells including the Müller glia and neurons, Cav1.3 and Cav1.4 are expressed in the retinal neurons with Cav1.4 exclusively expressed in the photoreceptor synaptic terminals. Mutations in the gene encoding Cav1.4 cause incomplete X-linked congenital stationary night blindness in humans. Even though Cav1.3 is present in the photoreceptor inner segments and the synaptic terminals in various vertebrate species, its role in vision is unclear, since genetic alterations in Cav1.3 are not associated with severe vision impairment in humans or in Cav1.3-null (Cav1.3−/−) mice. However, a failure to regulate Cav1.3 was found in a mouse model of Usher syndrome, the most common cause of combined deafness and blindness in humans, indicating that Cav1.3 may contribute to retinal function. In this report, we combined physiological and morphological data to demonstrate the role of Cav1.3 in retinal physiology and function that has been undervalued thus far. Through ex vivo and in vivo electroretinogram (ERG) recordings and immunohistochemical staining, we found that Cav1.3 plays a role in retinal light responses and synaptic plasticity. Pharmacological inhibition of Cav1.3 decreased ex vivo ERG a- and b-wave amplitudes. In Cav1.3−/− mice, their dark-adapted ERG a-, b-wave, and oscillatory potential amplitudes were significantly dampened, and implicit times were delayed compared to the wild type (WT). Furthermore, the density of ribbon synapses was reduced in the outer plexiform layer of Cav1.3−/− mice retinas. Hence, Cav1.3 plays a more prominent role in retinal physiology and function than previously reported. PMID:29259539

  15. The Contribution of L-Type Cav1.3 Channels to Retinal Light Responses.

    PubMed

    Shi, Liheng; Chang, Janet Ya-An; Yu, Fei; Ko, Michael L; Ko, Gladys Y-P

    2017-01-01

    L-type voltage-gated calcium channels (LTCCs) regulate tonic neurotransmitter release from sensory neurons including retinal photoreceptors. There are three types of LTCCs (Ca v 1.2, Ca v 1.3, and Ca v 1.4) expressed in the retina. While Ca v 1.2 is expressed in all retinal cells including the Müller glia and neurons, Ca v 1.3 and Ca v 1.4 are expressed in the retinal neurons with Ca v 1.4 exclusively expressed in the photoreceptor synaptic terminals. Mutations in the gene encoding Ca v 1.4 cause incomplete X-linked congenital stationary night blindness in humans. Even though Ca v 1.3 is present in the photoreceptor inner segments and the synaptic terminals in various vertebrate species, its role in vision is unclear, since genetic alterations in Ca v 1.3 are not associated with severe vision impairment in humans or in Ca v 1.3-null (Ca v 1.3 -/- ) mice. However, a failure to regulate Ca v 1.3 was found in a mouse model of Usher syndrome, the most common cause of combined deafness and blindness in humans, indicating that Ca v 1.3 may contribute to retinal function. In this report, we combined physiological and morphological data to demonstrate the role of Ca v 1.3 in retinal physiology and function that has been undervalued thus far. Through ex vivo and in vivo electroretinogram (ERG) recordings and immunohistochemical staining, we found that Ca v 1.3 plays a role in retinal light responses and synaptic plasticity. Pharmacological inhibition of Ca v 1.3 decreased ex vivo ERG a- and b-wave amplitudes. In Ca v 1.3 -/- mice, their dark-adapted ERG a-, b-wave, and oscillatory potential amplitudes were significantly dampened, and implicit times were delayed compared to the wild type (WT). Furthermore, the density of ribbon synapses was reduced in the outer plexiform layer of Ca v 1.3 -/- mice retinas. Hence, Ca v 1.3 plays a more prominent role in retinal physiology and function than previously reported.

  16. Effects of breathing pattern and inspired air conditions on breath condensate volume, pH, nitrite, and protein concentrations

    PubMed Central

    McCafferty, J; Bradshaw, T; Tate, S; Greening, A; Innes, J

    2004-01-01

    Background: The effects of breathing pattern and inspired air conditions on the volume and content of exhaled breath condensate (EBC) were investigated. Methods: Total exhaled water (TEW), EBC volume, pH, nitrite and protein concentrations were measured in three groups of 10 healthy subjects breathing into a condenser at different target minute ventilations (Vm), tidal volumes (Vt), and inspired air conditions. Results: The volumes of both TEW and EBC increased significantly with Vm. For Vm 7.5, 15 and 22.5 l/min, mean (SD) EBC was 627 (258) µl, 1019 (313) µl, and 1358 (364) µl, respectively (p<0.001) and TEW was 1879 (378) µl, 2986 (496) µl, and 4679 (700) µl, respectively (p<0.001). TEW was significantly higher than EBC, reflecting a condenser efficiency of 40% at a target Vm of 7.5 l/min which reduced to 29% at Vm 22.5 l/min. Lower Vt gave less TEW than higher Vt (26.6 v 30.7 µl/l, mean difference 4.1 (95% CI 2.6 to 5.6), p<0.001) and a smaller EBC volume (4.3 v 7.6 µl/l, mean difference 3.4 (95% CI 2.3 to 4.5), p<0.001). Cooler and drier inspired air yielded less water vapour and less breath condensate than standard conditions (p<0.05). Changes in the breathing pattern had no effect on EBC protein and nitrite concentrations and pH. Conclusion: These results show that condensate volume can be increased by using high Vt and increased Vm without compromising the dilution of the sample. PMID:15282391

  17. Combined sensing platform for advanced diagnostics in exhaled mouse breath

    NASA Astrophysics Data System (ADS)

    Fortes, Paula R.; Wilk, Andreas; Seichter, Felicia; Cajlakovic, Merima; Koestler, Stefan; Ribitsch, Volker; Wachter, Ulrich; Vogt, Josef; Radermacher, Peter; Carter, Chance; Raimundo, Ivo M.; Mizaikoff, Boris

    2013-03-01

    chromatography coupled to mass spectrometric detection. Here, we aim at potentially continuously analyzing the TTR via iHWGs and LS flow-through sensors requiring only minute (< 1 mL) sample volumes. Furthermore, this study explores non-linearities observed for the calibration functions of 12CO2 and 13CO2 potentially resulting from effects related to optical collision diameters e.g., in presence of molecular oxygen. It is anticipated that the simultaneous continuous analysis of oxygen via LS will facilitate the correction of these effects after inclusion within appropriate multivariate calibration models, thus providing more reliable and robust calibration schemes for continuously monitoring relevant breath constituents.

  18. Reliability of breath by breath spirometry and relative flow-time indices for pulmonary function testing in horses.

    PubMed

    Burnheim, K; Hughes, K J; Evans, D L; Raidal, S L

    2016-11-28

    Respiratory problems are common in horses, and are often diagnosed as a cause of poor athletic performance. Reliable, accurate and sensitive spirometric tests of airway function in resting horses would assist with the diagnosis of limitations to breathing and facilitate investigations of the effects of various treatments on breathing capacity. The evaluation of respiratory function in horses is challenging and suitable procedures are not widely available to equine practitioners. The determination of relative flow or flow-time measures is used in paediatric patients where compliance may limit conventional pulmonary function techniques. The aim of the current study was to characterise absolute and relative indices of respiratory function in healthy horses during eupnoea (tidal breathing) and carbon dioxide (CO 2 )-induced hyperpnoea (rebreathing) using a modified mask pneumotrachographic technique well suited to equine practice, and to evaluate the reliability of this technique over three consecutive days. Coefficients of variation, intra-class correlations, mean differences and 95% confidence intervals across all days of testing were established for each parameter. The technique provided absolute measures of respiratory function (respiratory rate, tidal volume, peak inspiratory and expiratory flows, time to peak flow) consistent with previous studies and there was no significant effect of day on any measure of respiratory function. Variability of measurements was decreased during hyperpnea caused by rebreathing CO 2 , but a number of relative flow-time variables demonstrated good agreement during eupnoeic respiration. The technique was well tolerated by horses and study findings suggest the technique is suitable for evaluation of respiratory function in horses. The use of relative flow-time variables provided reproducible (consistent) results, suggesting the technique may be of use for repeated measures studies in horses during tidal breathing or rebreathing.

  19. The relationship of normal body temperature, end-expired breath temperature, and BAC/BrAC ratio in 98 physically fit human test subjects.

    PubMed

    Cowan, J Mack; Burris, James M; Hughes, James R; Cunningham, Margaret P

    2010-06-01

    The relationship between normal body temperature, end-expired breath temperature, and blood alcohol concentration (BAC)/breath alcohol concentration (BrAC) ratio was studied in 98 subjects (84 men, 14 women). Subjects consumed alcohol sufficient to produce a BrAC of at least 0.06 g/210 L 45-75 min after drinking. Breath samples were analyzed using an Intoxilyzer 8000 specially equipped to measure breath temperature. Venous blood samples and body temperatures were then taken. The mean body temperature of the men (36.6 degrees C) was lower than the women (37.0 degrees C); however, their mean breath temperatures were virtually identical (men: 34.5 degrees C; women: 34.6 degrees C). The BAC exceeded the BrAC for every subject. BAC/BrAC ratios were calculated from the BAC and BrAC analytical results. There was no difference in the BAC/BrAC ratios for men (1:2379) and women (1:2385). The correlation between BAC and BrAC was high (r = 0.938, p < 0.0001), whereas the correlations between body temperature and end-expired breath temperature, body temperature and BAC/BrAC ratio, and breath temperature and BAC/BrAC ratio were much lower. Neither normal body temperature nor end-expired breath temperature was strongly associated with BAC/BrAC ratio.

  20. The rise in carboxyhemoglobin from repeated pulmonary diffusing capacity tests.

    PubMed

    Zavorsky, Gerald S

    2013-03-01

    The purpose of this study determined the rise in carboxyhemoglobin percentage (COHb) from repeated pulmonary diffusing capacity tests using 5 or 10s single breath-hold maneuvers. Five male and four female non-smokers [baseline COHb=1.2 (SD 0.5%)] performed repeated pulmonary diffusing capacity testing on two separate days. The days were randomized to either repeated 10s (0.28% CO), or 5s (0.28% CO, 55ppm NO) breath-hold maneuvers. Twenty-two 5s breath-hold maneuvers, each separated by 4min rest, raised COHb to 11.1 (1.4)% and minimally raised the methemoglobin percentage (METHb) by 0.3 (0.2)% to a value of 0.8 (0.2)%. After the 22nd test, pulmonary diffusing capacity for carbon monoxide (DLCO) was reduced by about 4mL/min/mmHg, equating to a 0.44% increase in COHb per 5s breath-hold maneuver and a concomitant 0.35mL/min/mmHg decrease in DLCO. Pulmonary diffusing capacity for nitric oxide (DLNO) was not altered after 22 tests. On another day, the 10s single breath-hold maneuver increased COHb by 0.64% per test, and reduced DLCO by 0.44mL/min/mmHg per test. In conclusion, 5s breath-hold maneuvers do not appreciably raise METHb or DLNO, and DLCO is only significantly reduced when COHb is at least 6%. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Determination of breath acetone in 149 type 2 diabetic patients using a ringdown breath-acetone analyzer.

    PubMed

    Sun, Meixiu; Chen, Zhuying; Gong, Zhiyong; Zhao, Xiaomeng; Jiang, Chenyu; Yuan, Yuan; Wang, Zhennang; Li, Yingxin; Wang, Chuji

    2015-02-01

    Over 90% of diabetic patients have Type 2 diabetes. Although an elevated mean breath acetone concentration has been found to exist in Type 1 diabetes (T1D), information on breath acetone in Type 2 diabetes (T2D) has yet to be obtained. In this study, we first used gas chromatography-mass spectrometry (GC-MS) to validate a ringdown breath-acetone analyzer based on the cavity-ringdown-spectroscopy technique, through comparing breath acetone concentrations in the range 0.5-2.5 ppm measured using both methods. The linear fitting of R = 0.99 suggests that the acetone concentrations obtained using both methods are consistent with a largest standard deviation of ±0.4 ppm in the lowest concentration of the range. Next, 620 breath samples from 149 T2D patients and 42 healthy subjects were collected and tested using the breath analyzer. Four breath samples were taken from each subject under each of four different conditions: fasting, 2 h post-breakfast, 2 h post-lunch, and 2 h post-dinner. Simultaneous blood glucose levels were also measured using a standard diabetic-management blood-glucose meter. For the 149 T2D subjects, their exhaled breath acetone concentrations ranged from 0.1 to 19.8 ppm; four different ranges of breath acetone concentration, 0.1-19.8, 0.1-7.1, 0.1-6.3, and 0.1-9.5 ppm, were obtained for the subjects under the four different conditions, respectively. For the 42 healthy subjects, their breath acetone concentration ranged from 0.1 to 2.6 ppm; four different ranges of breath acetone concentration, 0.3-2.6, 0.1-2.6, 0.1-1.7, and 0.3-1.6 ppm, were obtained for the four different conditions. The mean breath acetone concentration of the 149 T2D subjects was determined to be 1.5 ± 1.5 ppm, which was 1.5 times that of 1.0 ± 0.6 ppm for the 42 healthy subjects. No correlation was found between the breath acetone concentration and the blood glucose level of the T2D subjects and the healthy volunteers. This study using a relatively large number of

  2. Human metabolism and elimination of the anthocyanin, cyanidin-3-glucoside: a (13)C-tracer study.

    PubMed

    Czank, Charles; Cassidy, Aedín; Zhang, Qingzhi; Morrison, Douglas J; Preston, Tom; Kroon, Paul A; Botting, Nigel P; Kay, Colin D

    2013-05-01

    Evidence suggests that the consumption of anthocyanin-rich foods beneficially affects cardiovascular health; however, the absorption, distribution, metabolism, and elimination (ADME) of anthocyanin-rich foods are relatively unknown. We investigated the ADME of a (13)C5-labeled anthocyanin in humans. Eight male participants consumed 500 mg isotopically labeled cyanidin-3-glucoside (6,8,10,3',5'-(13)C5-C3G). Biological samples were collected over 48 h, and (13)C and (13)C-labeled metabolite concentrations were measured by using isotope-ratio mass spectrometry and liquid chromatography-tandem mass spectrometry. The mean ± SE percentage of (13)C recovered in urine, breath, and feces was 43.9 ± 25.9% (range: 15.1-99.3% across participants). The relative bioavailability was 12.38 ± 1.38% (5.37 ± 0.67% excreted in urine and 6.91 ± 1.59% in breath). Maximum rates of (13)C elimination were achieved 30 min after ingestion (32.53 ± 14.24 μg(13)C/h), whereas (13)C-labeled metabolites peaked (maximum serum concentration: 5.97 ± 2.14 μmol/L) at 10.25 ± 4.14 h. The half-life for (13)C-labeled metabolites ranged between 12.44 ± 4.22 and 51.62 ± 22.55 h. (13)C elimination was greatest between 0 and 1 h for urine (90.30 ± 15.28 μg/h), at 6 h for breath (132.87 ± 32.23 μg/h), and between 6 and 24 h for feces (557.28 ± 247.88 μg/h), whereas the highest concentrations of (13)C-labeled metabolites were identified in urine (10.77 ± 4.52 μmol/L) and fecal samples (43.16 ± 18.00 μmol/L) collected between 6 and 24 h. Metabolites were identified as degradation products, phenolic, hippuric, phenylacetic, and phenylpropenoic acids. Anthocyanins are more bioavailable than previously perceived, and their metabolites are present in the circulation for ≤48 h after ingestion. This trial was registered at clinicaltrials.gov as NCT01106729.

  3. Aspergillus fumigatus Cell Wall α-(1,3)-Glucan Stimulates Regulatory T-Cell Polarization by Inducing PD-L1 Expression on Human Dendritic Cells.

    PubMed

    Stephen-Victor, Emmanuel; Karnam, Anupama; Fontaine, Thierry; Beauvais, Anne; Das, Mrinmoy; Hegde, Pushpa; Prakhar, Praveen; Holla, Sahana; Balaji, Kithiganahalli N; Kaveri, Srini V; Latgé, Jean-Paul; Aimanianda, Vishukumar; Bayry, Jagadeesh

    2017-12-05

    Human dendritic cell (DC) response to α-(1,3)-glucan polysaccharide of Aspergillus fumigatus and ensuing CD4+ T-cell polarization are poorly characterized. α-(1,3)-Glucan was isolated from A. fumigatus conidia and mycelia cell wall. For the analysis of polarization, DCs and autologous naive CD4+ T cells were cocultured. Phenotype of immune cells was analyzed by flow cytometry, and cytokines by enzyme-linked immunosorbent assay (ELISA). Blocking antibodies were used to dissect the role of Toll-like receptor 2 (TLR2) and programmed death-ligand 1 (PD-L1) in regulating α-(1,3)-glucan-mediated DC activation and T-cell responses. DCs from TLR2-deficient mice were additionally used to consolidate the findings. α-(1,3)-Glucan induced the maturation of DCs and was dependent in part on TLR2. "α-(1,3)-Glucan-educated" DCs stimulated the activation of naive T cells and polarized a subset of these cells into CD4+CD25+FoxP3+ regulatory T cells (Tregs). Mechanistically, Treg stimulation by α-(1,3)-glucan was dependent on the PD-L1 pathway that negatively regulated interferon-gamma (IFN-γ) secretion. Short α-(1,3)-oligosaccharides lacked the capacity to induce maturation of DCs but significantly blocked α-(1,3)-glucan-induced Treg polarization. PD-L1 dictates the balance between Treg and IFN-γ responses induced by α-(1,3)-glucan. Our data provide a rationale for the exploitation of immunotherapeutic approaches that target PD-1-PD-L1 to enhance protective immune responses to A. fumigatus infections. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  4. Standardisation and application of the single-breath determination of nitric oxide uptake in the lung.

    PubMed

    Zavorsky, Gerald S; Hsia, Connie C W; Hughes, J Michael B; Borland, Colin D R; Guénard, Hervé; van der Lee, Ivo; Steenbruggen, Irene; Naeije, Robert; Cao, Jiguo; Dinh-Xuan, Anh Tuan

    2017-02-01

    Diffusing capacity of the lung for nitric oxide ( D LNO ), otherwise known as the transfer factor, was first measured in 1983. This document standardises the technique and application of single-breath D LNO This panel agrees that 1) pulmonary function systems should allow for mixing and measurement of both nitric oxide (NO) and carbon monoxide (CO) gases directly from an inspiratory reservoir just before use, with expired concentrations measured from an alveolar "collection" or continuously sampled via rapid gas analysers; 2) breath-hold time should be 10 s with chemiluminescence NO analysers, or 4-6 s to accommodate the smaller detection range of the NO electrochemical cell; 3) inspired NO and oxygen concentrations should be 40-60 ppm and close to 21%, respectively; 4) the alveolar oxygen tension ( P AO 2 ) should be measured by sampling the expired gas; 5) a finite specific conductance in the blood for NO (θNO) should be assumed as 4.5 mL·min -1 ·mmHg -1 ·mL -1 of blood; 6) the equation for 1/θCO should be (0.0062· P AO 2 +1.16)·(ideal haemoglobin/measured haemoglobin) based on breath-holding P AO 2 and adjusted to an average haemoglobin concentration (male 14.6 g·dL -1 , female 13.4 g·dL -1 ); 7) a membrane diffusing capacity ratio ( D MNO / D MCO ) should be 1.97, based on tissue diffusivity. Copyright ©ERS 2017.

  5. Breath-hold black-blood T1rho mapping improves liver T1rho quantification in healthy volunteers.

    PubMed

    Wáng, Yì Xiáng J; Deng, Min; Lo, Gladys G; Liang, Dong; Yuan, Jing; Chen, Weitian

    2018-03-01

    Background Recent researches suggest that T1rho may be a non-invasive and quantitative technique for detecting and grading liver fibrosis. Purpose To compare a multi-breath-hold bright-blood fast gradient echo (GRE) imaging and a single breath-hold single-shot fast spin echo (FSE) imaging with black-blood effect for liver parenchyma T1rho measurement and to study liver physiological T1rho value in healthy volunteers. Material and Methods The institutional Ethics Committee approved this study. 28 healthy participants (18 men, 10 women; age = 29.6 ± 5.1 years) underwent GRE liver T1rho imaging, and 20 healthy participants (10 men, 10 women; age = 36.9 ± 10.3 years) underwent novel black-blood FSE liver T1rho imaging, both at 3T with spin-lock frequency of 500 Hz. The FSE technique allows simultaneous acquisition of four spin lock times (TSLs; 1 ms, 10 ms, 30 ms, 50msec) in 10 s. Results For FSE technique the intra-scan repeatability intraclass correlation coefficient (ICC) was 0.98; while the inter-scan reproducibility ICC was 0.82 which is better than GRE technique's 0.76. Liver T1rho value in women tended to have a higher value than T1rho values in men (FSE: 42.28 ± 4.06 ms for women and 39.13 ± 2.12 ms for men; GRE: 44.44 ± 1.62 ms for women and 42.36 ± 2.00 ms for men) and FSE technique showed liver T1rho value decreased slightly as age increased. Conclusion Single breath-hold black-blood FSE sequence has better scan-rescan reproducibility than multi-breath-hold bright-blood GRE sequence. Gender and age dependence of liver T1rho in healthy participants is observed, with young women tending to have a higher T1rho measurement.

  6. When Breathing Interferes with Cognition: Experimental Inspiratory Loading Alters Timed Up-and-Go Test in Normal Humans.

    PubMed

    Nierat, Marie-Cécile; Demiri, Suela; Dupuis-Lozeron, Elise; Allali, Gilles; Morélot-Panzini, Capucine; Similowski, Thomas; Adler, Dan

    2016-01-01

    Human breathing stems from automatic brainstem neural processes. It can also be operated by cortico-subcortical networks, especially when breathing becomes uncomfortable because of external or internal inspiratory loads. How the "irruption of breathing into consciousness" interacts with cognition remains unclear, but a case report in a patient with defective automatic breathing (Ondine's curse syndrome) has shown that there was a cognitive cost of breathing when the respiratory cortical networks were engaged. In a pilot study of putative breathing-cognition interactions, the present study relied on a randomized design to test the hypothesis that experimentally loaded breathing in 28 young healthy subjects would have a negative impact on cognition as tested by "timed up-and-go" test (TUG) and its imagery version (iTUG). Progressive inspiratory threshold loading resulted in slower TUG and iTUG performance. Participants consistently imagined themselves faster than they actually were. However, progressive inspiratory loading slowed iTUG more than TUG, a finding that is unexpected with regard to the known effects of dual tasking on TUG and iTUG (slower TUG but stable iTUG). Insofar as the cortical networks engaged in response to inspiratory loading are also activated during complex locomotor tasks requiring cognitive inputs, we infer that competition for cortical resources may account for the breathing-cognition interference that is evidenced here.

  7. Imposed Work of Breathing for Flow Meters with In-Line versus Flow-Through Technique during Simulated Neonatal Breathing.

    PubMed

    Donaldsson, Snorri; Falk, Markus; Jonsson, Baldvin; Drevhammar, Thomas

    2015-01-01

    The ability to determine airflow during nasal CPAP (NCPAP) treatment without adding dead space or resistance would be useful when investigating the physiologic effects of different NCPAP systems on breathing. The aim of this study was to investigate the effect on pressure stability of different flow measuring devices at the in-line and flow-through position, using simulated neonatal breathing. Six different flow measure devices were evaluated by recording pressure changes and imposed work of breathing for breaths with 16 and 32 ml tidal volumes. The tests were performed initially with the devices in an in line position and with 5 and 10 L/min using flow through technique, without CPAP. The flow meters were then subsequently tested with an Infant Flow CPAP system at 3, 5 and 8 cm H2O pressure using flow through technique. The quality of the recorded signals was compared graphically. The resistance of the measuring devices generated pressure swings and imposed work of breathing. With bias flow, the resistance also generated CPAP pressure. Three of the devices had low resistance and generated no changes in pressure stability or CPAP pressure. The two devices intended for neonatal use had the highest measured resistance. The importance of pressure stability and increased work of breathing during non-invasive respiratory support are insufficiently studied. Clinical trials using flow-through technique have not focused on pressure stability. Our results indicate that a flow-through technique might be a way forward in obtaining a sufficiently high signal quality without the added effects of rebreathing and increased work of breathing. The results should stimulate further research and the development of equipment for dynamic flow measurements in neonates.

  8. VizieR Online Data Catalog: L1157-B1 DCN (2-1) and H13CN (2-1) datacubes (Busquet+,

    NASA Astrophysics Data System (ADS)

    Busquet, G.; Fontani, F.; Viti, S.; Codella, C.; Lefloch, B.; Benedettini, M.; Ceccarellli, C.

    2017-06-01

    IRAM NOEMA observations of DCN(2-1) and H13CN(2-1) towa brightest bow-shock B1 of the L1157 molecular outflow. All data cubes are provided in fits format smoothed to a velocity resolution of 0.5km/s. (2 data files).

  9. [Efficacy of preoxygenation using tidal volume breathing: a comparison of Mapleson A, Bain's and Circle system].

    PubMed

    Arora, Suman; Gupta, Priyanka; Arya, Virender Kumar; Bhatia, Nidhi

    Efficacy of preoxygenation depends upon inspired oxygen concentration, its flow rate, breathing system configuration and patient characteristics. We hypothesized that in actual clinical scenario, where breathing circuit is not primed with 100% oxygen, patients may need more time to achieve EtO 2 ≥90%, and this duration may be different among various breathing systems. We thus studied the efficacy of preoxygenation using unprimed Mapleson A, Bain's and Circle system with tidal volume breathing at oxygen flow rates of 5L.min -1 and 10L.min -1 . Patients were randomly allocated into one of the six groups, wherein they were preoxygenated using either Mapleson A, Bain's or Circle system at O 2 flow rate of either 5L.min -1 or 10L.min -1 . The primary outcome measure of our study was the time taken to achieve EtO 2 ≥90% at 5 and 10L.min -1 flow rates. At oxygen flow rate of 5L.min -1 , time to reach EtO 2 ≥90% was significantly longer with Bain's system (3.7±0.67min) than Mapleson A and Circle system (2.9±0.6, 3.3±0.97min, respectively). However at oxygen flow rate of 10L.min -1 this time was significantly shorter and comparable among all the three breathing systems (2.33±0.38min with Mapleson, 2.59±0.50min with Bain's and 2.60±0.47min with Circle system). With spontaneous normal tidal volume breathing at oxygen flow rate of 5L.min -1 , Mapleson A can optimally preoxygenate patients within 3min while Bain's and Circle system require more time. However at O 2 flow rate of 10L.min -1 all the three breathing systems are capable of optimally preoxygenating the patients in less than 3min. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  10. Effects of Diaphragmatic Breathing Patterns on Balance: A Preliminary Clinical Trial.

    PubMed

    Stephens, Rylee J; Haas, Mitchell; Moore, William L; Emmil, Jordan R; Sipress, Jayson A; Williams, Alex

    The purpose of this study was to determine the feasibility of performing a larger study to determine if training in diaphragmatic breathing influences static and dynamic balance. A group of 13 healthy persons (8 men, 5 women), who were staff, faculty, or students at the University of Western States participated in an 8-week breathing and balance study using an uncontrolled clinical trial design. Participants were given a series of breathing exercises to perform weekly in the clinic and at home. Balance and breathing were assessed at the weekly clinic sessions. Breathing was evaluated with Liebenson's breathing assessment, static balance with the Modified Balance Error Scoring System, and dynamic balance with OptoGait's March in Place protocol. Improvement was noted in mean diaphragmatic breathing scores (1.3 to 2.6, P < .001), number of single-leg stance balance errors (7.1 to 3.8, P = .001), and tandem stance balance errors (3.2 to 0.9, P = .039). A decreasing error rate in single-leg stance was associated with improvement in breathing score within participants over the 8 weeks of the study (-1.4 errors/unit breathing score change, P < .001). Tandem stance performance did not reach statistical significance (-0.5 error/unit change, P = .118). Dynamic balance was insensitive to balance change, being error free for all participants throughout the study. This proof-of-concept study indicated that promotion of a costal-diaphragmatic breathing pattern may be associated with improvement in balance and suggests that a study of this phenomenon using an experimental design is feasible. Copyright © 2017. Published by Elsevier Inc.

  11. Chemical sensors for breath gas analysis: the latest developments at the Breath Analysis Summit 2013.

    PubMed

    Tisch, Ulrike; Haick, Hossam

    2014-06-01

    Profiling the body chemistry by means of volatile organic compounds (VOCs) in the breath opens exciting new avenues in medical diagnostics. Gas sensors could provide ideal platforms for realizing portable, hand-held breath testing devices in the near future. This review summarizes the latest developments and applications in the field of chemical sensors for diagnostic breath testing that were presented at the Breath Analysis Summit 2013 in Wallerfangen, Germany. Considerable progress has been made towards clinically applicable breath testing devices, especially by utilizing chemo-sensitive nanomaterials. Examples of several specialized breath testing applications are presented that are either based on stand-alone nanomaterial-based sensors being highly sensitive and specific to individual breath compounds over others, or on combinations of several highly specific sensors, or on experimental nanomaterial-based sensors arrays. Other interesting approaches include the adaption of a commercially available MOx-based sensor array to indirect breath testing applications, using a sample pre-concentration method, and the development of compact integrated GC-sensor systems. The recent trend towards device integration has led to the development of fully integrated prototypes of point-of-care devices. We describe and compare the performance of several prototypes that are based on different sensing technologies and evaluate their potential as low-cost and readily available next-generation medical devices.

  12. A Gaussian method to improve work-of-breathing calculations.

    PubMed

    Petrini, M F; Evans, J N; Wall, M A; Norman, J R

    1995-01-01

    The work of breathing is a calculated index of pulmonary function in ventilated patients that may be useful in deciding when to wean and when to extubate. However, the accuracy of the calculated work of breathing of the patient (WOBp) can suffer from artifacts introduced by coughing, swallowing, and other non-breathing maneuvers. The WOBp in this case will include not only the usual work of inspiration, but also the work of performing these non-breathing maneuvers. The authors developed a method to objectively eliminate the calculated work of these movements from the work of breathing, based on fitting to a Gaussian curve the variable P, which is obtained from the difference between the esophageal pressure change and the airway pressure change during each breath. In spontaneously breathing adults the normal breaths fit the Gaussian curve, while breaths that contain non-breathing maneuvers do not. In this Gaussian breath-elimination method (GM), breaths that are two standard deviations from that mean obtained by the fit are eliminated. For normally breathing control adult subjects, GM had little effect on WOBp, reducing it from 0.49 to 0.47 J/L (n = 8), while there was a 40% reduction in the coefficient of variation. Non-breathing maneuvers were simulated by coughing, which increased WOBp to 0.88 (n = 6); with the GM correction, WOBp was 0.50 J/L, a value not significantly different from that of normal breathing. Occlusion also increased WOBp to 0.60 J/L, but GM-corrected WOBp was 0.51 J/L, a normal value. As predicted, doubling the respiratory rate did not change the WOBp before or after the GM correction.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Redefining the MED13L syndrome

    PubMed Central

    Adegbola, Abidemi; Musante, Luciana; Callewaert, Bert; Maciel, Patricia; Hu, Hao; Isidor, Bertrand; Picker-Minh, Sylvie; Le Caignec, Cedric; Delle Chiaie, Barbara; Vanakker, Olivier; Menten, Björn; Dheedene, Annelies; Bockaert, Nele; Roelens, Filip; Decaestecker, Karin; Silva, João; Soares, Gabriela; Lopes, Fátima; Najmabadi, Hossein; Kahrizi, Kimia; Cox, Gerald F; Angus, Steven P; Staropoli, John F; Fischer, Ute; Suckow, Vanessa; Bartsch, Oliver; Chess, Andrew; Ropers, Hans-Hilger; Wienker, Thomas F; Hübner, Christoph; Kaindl, Angela M; Kalscheuer, Vera M

    2015-01-01

    Congenital cardiac and neurodevelopmental deficits have been recently linked to the mediator complex subunit 13-like protein MED13L, a subunit of the CDK8-associated mediator complex that functions in transcriptional regulation through DNA-binding transcription factors and RNA polymerase II. Heterozygous MED13L variants cause transposition of the great arteries and intellectual disability (ID). Here, we report eight patients with predominantly novel MED13L variants who lack such complex congenital heart malformations. Rather, they depict a syndromic form of ID characterized by facial dysmorphism, ID, speech impairment, motor developmental delay with muscular hypotonia and behavioral difficulties. We thereby define a novel syndrome and significantly broaden the clinical spectrum associated with MED13L variants. A prominent feature of the MED13L neurocognitive presentation is profound language impairment, often in combination with articulatory deficits. PMID:25758992

  14. Redefining the MED13L syndrome.

    PubMed

    Adegbola, Abidemi; Musante, Luciana; Callewaert, Bert; Maciel, Patricia; Hu, Hao; Isidor, Bertrand; Picker-Minh, Sylvie; Le Caignec, Cedric; Delle Chiaie, Barbara; Vanakker, Olivier; Menten, Björn; Dheedene, Annelies; Bockaert, Nele; Roelens, Filip; Decaestecker, Karin; Silva, João; Soares, Gabriela; Lopes, Fátima; Najmabadi, Hossein; Kahrizi, Kimia; Cox, Gerald F; Angus, Steven P; Staropoli, John F; Fischer, Ute; Suckow, Vanessa; Bartsch, Oliver; Chess, Andrew; Ropers, Hans-Hilger; Wienker, Thomas F; Hübner, Christoph; Kaindl, Angela M; Kalscheuer, Vera M

    2015-10-01

    Congenital cardiac and neurodevelopmental deficits have been recently linked to the mediator complex subunit 13-like protein MED13L, a subunit of the CDK8-associated mediator complex that functions in transcriptional regulation through DNA-binding transcription factors and RNA polymerase II. Heterozygous MED13L variants cause transposition of the great arteries and intellectual disability (ID). Here, we report eight patients with predominantly novel MED13L variants who lack such complex congenital heart malformations. Rather, they depict a syndromic form of ID characterized by facial dysmorphism, ID, speech impairment, motor developmental delay with muscular hypotonia and behavioral difficulties. We thereby define a novel syndrome and significantly broaden the clinical spectrum associated with MED13L variants. A prominent feature of the MED13L neurocognitive presentation is profound language impairment, often in combination with articulatory deficits.

  15. Breathing Mode in Complex Plasmas

    NASA Astrophysics Data System (ADS)

    Fujioka, K.; Henning, C.; Ludwig, P.; Bonitz, M.; Melzer, A.; Vitkalov, S.

    2007-11-01

    The breathing mode is a fundamental normal mode present in Coulomb systems, and may have utility in identifying particle charge and the Debye length of certain systems. The question remains whether this mode can be extended to strongly coupled Yukawa balls [1]. These systems are characterized by particles confined within a parabolic potential well and interacting through a shielded Coulomb potential [2,3]. The breathing modes for a variety of systems in 1, 2, and 3 dimensions are computed by solving the eigenvalue problem given by the dynamical (Hesse) matrix. These results are compared to theoretical investigations that assume a strict definition for a breathing mode within the system, and an analysis is made of the most fitting model to utilize in the study of particular systems of complex plasmas [1,4]. References [1] T.E. Sheridan, Phys. of Plasmas. 13, 022106 (2006)[2] C. Henning et al., Phys. Rev. E 74, 056403 (2006)[3] M. Bonitz et al., Phys. Rev. Lett. 96, 075001 (2006)[4] C. Henning et al., submitted for publication

  16. 13. "TEST STANDS NOS. 11, 13, & 15; CONCRETE STRUCTURAL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. "TEST STANDS NOS. 1-1, 1-3, & 1-5; CONCRETE STRUCTURAL SECTIONS AND DETAILS." Specifications No. OC12-50-10; Drawing No. 60-09-04; no sheet number within title block. D.O. SERIES 1109/18, Rev. D. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract DA-04353 Eng. 177, Rev. D, no change; Date: 18 Dec. 1951. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-5, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  17. Imposed Work of Breathing for Flow Meters with In-Line versus Flow-Through Technique during Simulated Neonatal Breathing

    PubMed Central

    2015-01-01

    Background The ability to determine airflow during nasal CPAP (NCPAP) treatment without adding dead space or resistance would be useful when investigating the physiologic effects of different NCPAP systems on breathing. The aim of this study was to investigate the effect on pressure stability of different flow measuring devices at the in-line and flow-through position, using simulated neonatal breathing. Methods Six different flow measure devices were evaluated by recording pressure changes and imposed work of breathing for breaths with 16 and 32 ml tidal volumes. The tests were performed initially with the devices in an in line position and with 5 and 10 L/min using flow through technique, without CPAP. The flow meters were then subsequently tested with an Infant Flow CPAP system at 3, 5 and 8 cm H2O pressure using flow through technique. The quality of the recorded signals was compared graphically. Results The resistance of the measuring devices generated pressure swings and imposed work of breathing. With bias flow, the resistance also generated CPAP pressure. Three of the devices had low resistance and generated no changes in pressure stability or CPAP pressure. The two devices intended for neonatal use had the highest measured resistance. Conclusion The importance of pressure stability and increased work of breathing during non-invasive respiratory support are insufficiently studied. Clinical trials using flow-through technique have not focused on pressure stability. Our results indicate that a flow-through technique might be a way forward in obtaining a sufficiently high signal quality without the added effects of rebreathing and increased work of breathing. The results should stimulate further research and the development of equipment for dynamic flow measurements in neonates. PMID:26192188

  18. Effect of Yogic Breathing on Accommodate Braille Version of Six-letter Cancellation Test in Students with Visual Impairment.

    PubMed

    Pradhan, Balaram; Mohanty, Soubhagyalaxmi; Hankey, Alex

    2018-01-01

    Attentional processes tend to be less well developed in the visually impaired, who require special training to develop them fully. Yogic breathing which alters the patterns of respiration has been shown to enhance attention skills. Letter cancellation tests are well-established tools to measure attention and attention span. Here, a modified Braille version of the six-letter cancellation test (SLCT) was used for students with visual impairment (VI). This study aimed to assess the immediate effects of Bhramari Pranayama (BhPr) and breath awareness (BA) on students with VI. This study was a self-as-control study held on 2 consecutive days, on 19 participants (8 males, 11 females), with a mean age of 15.89 ± 1.59 years, randomized into two groups. On the 1 st day, Group 1 performed 10 min breath awareness and Group 2 performed Bhramari ; on the 2 nd day, practices were reversed. Assessments used a SLCT specially adapted for the visually impaired before and after each session. The Braille letter cancellation test was successfully taken by 19 students. Scores significantly improved after both techniques for each student following practices on both days ( P < 0.001). BhPr may have more effect on attention performance than BA as wrong scores significantly increased following BA ( P < 0.05), but the increase in the score after Bhramari was not significant. Despite the small sample size improvement in attentional processes by both yoga breathing techniques was robust. Attentional skills were definitely enhanced. Long-term practice should be studied.

  19. Effect of Yogic Breathing on Accommodate Braille Version of Six-letter Cancellation Test in Students with Visual Impairment

    PubMed Central

    Pradhan, Balaram; Mohanty, Soubhagyalaxmi; Hankey, Alex

    2018-01-01

    Context: Attentional processes tend to be less well developed in the visually impaired, who require special training to develop them fully. Yogic breathing which alters the patterns of respiration has been shown to enhance attention skills. Letter cancellation tests are well-established tools to measure attention and attention span. Here, a modified Braille version of the six-letter cancellation test (SLCT) was used for students with visual impairment (VI). Aim: This study aimed to assess the immediate effects of Bhramari Pranayama (BhPr) and breath awareness (BA) on students with VI. Methods: This study was a self-as-control study held on 2 consecutive days, on 19 participants (8 males, 11 females), with a mean age of 15.89 ± 1.59 years, randomized into two groups. On the 1st day, Group 1 performed 10 min breath awareness and Group 2 performed Bhramari; on the 2nd day, practices were reversed. Assessments used a SLCT specially adapted for the visually impaired before and after each session. Results: The Braille letter cancellation test was successfully taken by 19 students. Scores significantly improved after both techniques for each student following practices on both days (P < 0.001). BhPr may have more effect on attention performance than BA as wrong scores significantly increased following BA (P < 0.05), but the increase in the score after Bhramari was not significant. Conclusions: Despite the small sample size improvement in attentional processes by both yoga breathing techniques was robust. Attentional skills were definitely enhanced. Long-term practice should be studied. PMID:29755219

  20. Synthesis and performance of Li[(Ni1/3Co1/3Mn1/3)(1-x)Mgx]O2 prepared from spent lithium ion batteries.

    PubMed

    Weng, Yaqing; Xu, Shengming; Huang, Guoyong; Jiang, Changyin

    2013-02-15

    To reduce cost and secondary pollution of spent lithium ion battery (LIB) recycling caused by complicated separation and purification, a novel simplified recycling process is investigated in this paper. Removal of magnesium is a common issue in hydrometallurgy process. Considering magnesium as an important additive in LIB modification, tolerant level of magnesium in leachate is explored as well. Based on the novel recycling technology, Li[(Ni(1/3)Co(1/3)Mn(1/3))(1-x)Mg(x)]O(2) (0 ≤ x ≤ 0.05) cathode materials are achieved from spent LIB. Tests of XRD, SEM, TG-DTA and so on are carried out to evaluate material properties. Electrochemical test shows an initial charge and discharge capacity of the regenerated LiNi(1/3)Co(1/3)Mn(1/3)O(2) to be 175.4 mAh g(-1) and 152.7 mAh g(-1) (2.7-4.3 V, 0.2C), respectively. The capacity remains 94% of the original value after 50 cycles (2.7-4.3 V, 1C). Results indicate that presence of magnesium up to x=0.01 has no significant impact on overall performance of Li[(Ni(1/3)Co(1/3)Mn(1/3))(1-x)Mg(x)]O(2). As a result, magnesium level as high as 360 mg L(-1) in leachate remains tolerable. Compared with conventional limitation of magnesium content, the elimination level of magnesium exceeded general impurity-removal requirement. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Direct comparison of solid-phase gastric emptying times assessed by means of a carbon isotope-labeled sodium acetate breath test and technetium Tc 99m albumin colloid radioscintigraphy in healthy cats.

    PubMed

    Schmitz, Silke; Götte, Birte; Borsch, Christian; Kunz, Clemens; Failing, Klaus; Neiger, Reto

    2014-07-01

    To directly compare solid-phase gastric emptying times assessed by means of a [(13)C]sodium acetate breath test ([(13)C]-SABT) and technetium Tc 99m albumin colloid radioscintigraphy ((99m)Tc-ACR) in healthy cats. 12 healthy cats. After ingestion of a test meal containing 50 mg of [(13)C]sodium acetate and 250 MBq of (99m)Tc-albumin colloid, each cat underwent simultaneous [(13)C]-SABT and (99m)Tc-ACR on 2 consecutive days. Breath samples and scintigrams were acquired at 30, 60, 90, 120, 150, 180, 210, 240, 300, 360, 480, and 600 minutes after meal ingestion. Quartiles of gastric emptying (25%, 50%, and 75%) were calculated for breath test analysis by use of the area under the curve of the (13)C:(12)C ratio. Quartiles of gastric emptying times were extrapolated from the scintigraphic findings by beans of nonlinear curve regression analysis. Mean ± SD gastric half-emptying (50%) times obtained with [(13)C]-SABT and (99m)Tc-ACR, were 239 ± 28 minutes and 276 ± 59 minutes, respectively. A 2-way repeated-measures ANOVA revealed that mean gastric emptying times determined with [(13)C]-SABT and (99m)Tc-ACR differed significantly. For the stages of gastric emptying, Pearson correlation between the 2 methods was good at 25% (r = 0.655) and weak at 50% (r = 0.588) and 75% (r = 0.566)of gastric emptying. Results indicated that the [(13)C]-SABT can be a valid alternative to (99m)Tc-ACR in healthy cats; it was easy to perform, was tolerated well by the cats, and had acceptable correlation to scintigraphic findings at gastric emptying of 25%, 50% and 75%. Studies in cats with delayed gastric emptying will be needed to verify the validity of the [(13)C]-SABT.

  2. Performance of acidified 14C-urea capsule breath test during pantoprazole and ranitidine treatment.

    PubMed

    Oztürk, Emel; Yeşilova, Zeki; Ilgan, Seyfettin; Ozgüven, Mehmet; Dağalp, Kemal

    2009-07-01

    Urea breath test (UBT) results could be false negative in patients taking antisecretory drugs. This effect would be prevented by citric acid administration during UBT. We prospectively investigated whether acidified 14C-urea capsule prevents false negative UBT results in patients taking antisecretory drugs and show interference with the duration of medications. Sixty Helicobacter pylori positive patients were included. Pantoprazole (40 mg/day) was given to 27 patients for 28 days and ranitidine (300 mg. o.d.) to 33 patients for 60 days. Urea breath tests were repeated on days 14 and 28 in both groups and on day 60 in the ranitidine group. The baseline mean breath counts of two groups did not show any significant difference. Pantoprazole led to a significant decrease in mean breath counts on day 14 (P < 0.005). Six of 27 and 3 of 25 patients taking pantoprazole developed negative or equivocal UBT results on days 14 and 28, respectively. Two of 32, 2 of 32 and 3 of 21 patients taking ranitidine developed negative or equivocal UBT results on days 14, 28 and 60, respectively. The use of acidified 14C-urea capsule did not prevent false negative UBT results in patients taking pantoprazole and ranitidine, and the duration of medication does not affect the test results.

  3. Stress responses in alfalfa (Medicago sativa L. )

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kessmann, H.; Edwards, R.; Dixon, R.A.

    1990-09-01

    The isoflavonoid conjugates medicarpin-3-O-glucoside-6{double prime}-O-malonate (MGM), afrormosin-7-O-glucoside (AG), and afrormosin-7-O-glucoside-6{double prime}-O-malonate (AGM) were isolated and characterized from cell suspension cultures of alfalfa (Medicago sativa L.), where they were the major constitutive secondary metabolites. They were also found in alfalfa roots but not in other parts of the plant. The phytoalexin medicarpin accumulated rapidly in suspension cultured cells treated with elicitor from Colletotrichum lindemuthianum, and this was subsequently accompanied by an increase in the levels of MGM. In contrast, net accumulation of afrormosin conjugates was not affected by elicitor treatment. Labeling studies with ({sup 14}C)phenylalanine indicated that afrormosin conjugates were themore » major de novo synthesized isoflavonoid products in unelicited cells. During elicitation, ({sup 14}C)phenylalanine was incorporated predominantly into medicarpin, although a significant proportion of the newly synthesized medicarpin was also conjugated. Treatment of {sup 14}C-labeled, elicited cells with L-{alpha}-aminooxy-{beta}-phenylpropionic acid, a potent inhibitor of PAL activity in vivo, resulted in the initial appearance of labeled medicarpin of very low specific activity, suggesting that the phytoalexin could be released from a preformed conjugate under these conditions. Our data draw attention to the involvement of isoflavone hydroxylases during the constitutive and elicitor-induced accumulation of isoflavonoids and their conjugates in alfalfa cell cultures.« less

  4. 13. "CIVIL, SITE PLAN AND VICINITY MAP, AREA LOCATIONS." Test ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. "CIVIL, SITE PLAN AND VICINITY MAP, AREA LOCATIONS." Test Area 1-125. Specifications No. ENG (NASA)-04-35363-1; Drawing No. 60-09-34; sheet 11. Ref. No. C-l. D.O. SERIES 1597/1. Approved for siting on 24 April 1962. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Leuhman Ridge near Highways 58 & 395, Boron, Kern County, CA

  5. Detection of creatinine in exhaled breath of humans with chronic kidney disease by extractive electrospray ionization mass spectrometry.

    PubMed

    Zeng, Qian; Li, Penghui; Cai, Yunfeng; Zhou, Wei; Wang, Haidong; Luo, Jiao; Ding, Jianhua; Chen, Huanwen

    2016-02-09

    Exhaled breath contains chemicals that have a diagnostic value in human pathologies. Here in vivo breath analysis of creatinine has been demonstrated by constructing a novel platform based on extractive electrospray ionization mass spectrometry (EESI-MS) without sample pretreatment. Under optimized experimental conditions, the limit of creatinine detection in breath was 30.57 ng L(-1), and the linear range of detection was from 0.3 μg L(-1) to 100 μg L(-1). The concentration range of creatinine in the exhaled breath of 50 volunteers with chronic kidney disease was from 42 pptv to 924 pptv, and the range of the relative standard deviations was from 9.3% to 19.2%. The method provides high sensitivity, high specificity and high speed for semi-quantitative analysis of creatinine in exhaled human breath.

  6. Benzene levels in ambient air and breath of smokers and nonsmokers in urban and pristine environments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wester, R.C.; Maibach, H.I.; Gruenke, L.D.

    Benzene levels in human breath and in ambient air were compared in the urban area of San Francisco (SF) and in a more remote coastal pristine setting of Stinson Beach, Calif. (SB). Benzene analysis was done by gas chromatography-mass spectroscopy (GC-MS). Ambient benzene levels were sevenfold higher in SF (2.6 +/- 1.3 ppb, n = 25) than SB (0.38 +/- 0.39 ppb, n = 21). In SF, benzene in smokers' breath (6.8 +/- 3.0 ppb) was greater than in nonsmokers' breath (2.5 +/- 0.8 ppb) and smokers' ambient air (3.3 +/- 0.8 ppb). In SB the same pattern was observed:more » benzene in smokers' breath was higher than in nonsmokers' breath and ambient air. Benzene in SF nonsmokers' breath was greater than in SB nonsmokers' breath. Marijuana-only smokers had benzene breath levels between those of smokers and nonsmokers. There was little correlation between benzene in breath and number of cigarettes smoked, or with other benzene exposures such as diet. Of special interest was the finding that benzene in breath of SF nonsmokers (2.5 +/- 0.8 ppb) was greater than that in nonsmokers ambient air (1.4 +/- 0.1 ppb). The same was true in SB, where benzene in nonsmokers breath was greater than ambient air (1.8 +/- 0.2 ppb versus 1.0 +/- 0.1 ppb on d 1 and 1.3 +/- 0.3 ppb versus 0.23 +/- 0.18 ppb on d 2). This suggests an additional source of benzene other than outdoor ambient air.« less

  7. Prevalence and risk factors of helicobacter pylori in Turkey: a nationally-representative, cross-sectional, screening with the 13C-Urea breath test

    PubMed Central

    2013-01-01

    Background Helicobacter pylori is an important global pathogen infecting approximately 50% of the world’s population. This study was undertaken in order to estimate the prevalence rate of Helicobacter pylori infections among adults living in Turkey and to investigate the associated risk factors. Method This study was a nationally representative cross sectional survey, using weighted multistage stratified cluster sampling. All individuals aged ≥18 years in the selected households were invited to participate in the survey. Ninety two percent (n = 2382) of the households in 55 cities participated; 4622 individuals from these households were tested with the 13C-Urea breath test. Helicobacter pylori prevalence and associated factors were analysed by the t test, chi square and multiple logistic regression with SPSS11.0. Results The weighted overall prevalence was 82.5% (95% CI: 81.0-84.2) and was higher in men. It was lowest in the South which has the major fruit growing areas of the country. The factors included in the final model were sex, age, education, marital status, type of insurance (social security), residential region, alcohol use, smoking, drinking water source. While education was the only significant factor for women, residential region, housing tenure, smoking and alcohol use were significant for men in models by sex. Conclusion In Turkey, Helicobacter pylori prevalence was found to be very high. Individuals who were women, elderly adults, single, had a high educational level, were living in the fruit growing region, had social security from Emekli Sandigi, were drinking bottled water, non smokers and regular alcohol consumers, were under less risk of Helicobacter pylori infection than others. PMID:24359515

  8. 49 CFR 40.243 - What is the procedure for an alcohol screening test using an EBT or non-evidential breath ASD?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false What is the procedure for an alcohol screening test using an EBT or non-evidential breath ASD? 40.243 Section 40.243 Transportation Office of the...-evidential breath ASD? As the BAT or STT, you must take the following steps: (a) Select, or allow the...

  9. 49 CFR 40.243 - What is the procedure for an alcohol screening test using an EBT or non-evidential breath ASD?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false What is the procedure for an alcohol screening test using an EBT or non-evidential breath ASD? 40.243 Section 40.243 Transportation Office of the...-evidential breath ASD? As the BAT or STT, you must take the following steps: (a) Select, or allow the...

  10. Analysis of 13C-mixed triacylglycerol in stool by bulk (EA-IRMS) and compound specific (GC/MS) methods.

    PubMed

    Slater, C; Ling, S C; Preston, T; Weaver, L T

    2002-06-01

    This paper was presented in poster form at the 17th International Congress of Nutrition, August 27-31, Vienna, Austria (Annals of Nutrition & Metabolism 2001; 45(Suppl.1):349). Some of the data were also presented in poster form at the British Society of Gastroenterology Meeting, March 18-21, Glasgow, UK (Gut 2001; 48(Suppl.1):A91). The 13C-mixed triacylglycerol (MTG) breath test is used to measure intraluminal fat digestion. In normal digestion, 20-40% of the ingested 13C label is recovered in breath CO2. We aimed to identify the proportions of ingested label excreted in stool, as well as breath following ingestion of 13C-MTG by children with impaired exocrine pancreatic function and healthy controls. 13C enrichment of breath samples was measured by continuous flow isotope ratio mass spectrometry (IRMS) and cumulative percent dose recovered (cPDR) in 10 h was calculated. Total 13C of a faecal fat extract from each stool was measured by elemental analyser-IRMS, and 13C enrichment and concentration of the TBDMS derivative of octanoic acid was measured by GC/MS after hydrolysis of the fat extract. Stool 5-day cPDR was calculated. Mean breath cPDR was 35%. Mean cPDR in stool by combustion-IRMS and GC/ MS, respectively, was 0.8% and 1.0%. Therefore, the remaining 64% of the 13C label must remain in the body and variability in breath cPDR is due to postabsorptive rather than predigestive factors.

  11. Stable isotope analysis of CO2 in breath indicates metabolic fuel shifts in torpid arctic ground squirrels.

    PubMed

    Lee, Trixie N; Richter, Melanie M; Williams, Cory T; Tøien, Øivind; Barnes, Brian M; O'Brien, Diane M; Buck, C Loren

    2017-07-01

    Stable carbon isotope ratios (δ 13 C) in breath show promise as an indicator of immediate metabolic fuel utilization in animals because tissue lipids have a lower δ 13 C value than carbohydrates and proteins. Metabolic fuel consumption is often estimated using the respiratory exchange ratio (RER), which has lipid and carbohydrate boundaries, but does not differentiate between protein and mixed fuel catabolism at intermediate values. Because lipids have relatively low δ 13 C values, measurements of stable carbon isotopes in breath may help distinguish between catabolism of protein and mixed fuel that includes lipid. We measured breath δ 13 C and RER concurrently in arctic ground squirrels (Urocitellus parryii) during steady-state torpor at ambient temperatures from -2 to -26°C. As predicted, we found a correlation between RER and breath δ 13 C values; however, the range of RER in this study did not reach intermediate levels to allow further resolution of metabolic substrate use with the addition of breath δ 13 C measurements. These data suggest that breath δ 13 C values are 1.1‰ lower than lipid tissue during pure lipid metabolism. From RER, we determined that arctic ground squirrels rely on nonlipid fuel sources for a significant portion of energy during torpor (up to 37%). The shift toward nonlipid fuel sources may be influenced by adiposity of the animals in addition to thermal challenge. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Development of extractive electrospray ionization ion trap mass spectrometry for in vivo breath analysis.

    PubMed

    Ding, Jianhua; Yang, Shuiping; Liang, Dapeng; Chen, Huanwen; Wu, Zhuanzhang; Zhang, Lili; Ren, Yulin

    2009-10-01

    In metabolomics studies and clinical diagnosis, interest is increasing in the rapid analysis of exhaled breath. In vivo breath analysis offers a unique, unobtrusive, non-invasive method of investigating human metabolism. To analyze breath in vivo, we constructed a novel platform of extractive electrospray ionization (EESI) ion trap mass spectrometry (ITMS) using a home-made EESI source coupled to a linear trap quadrupole mass spectrometer. A reference compound (authentic n-octyl amine) was used to evaluate effects of systematically varying selected characteristics of the EESI source on signal intensity. Under the optimized working conditions, metabolic changes of human bodies were in vivo followed by performing rapid breath analysis using the multi-stage EESI-ITMS tandem mass spectrometry platform. For nicotine, a limit of determination was found to be 0.05 fg mL(-1) (S/N = 3, RSD = 5.0 %, n = 10) for nicotine in aerosol standard samples; the dynamic response range was from 0.0155 pg mL(-1) to 155 pg mL(-1). The concentration of nicotine in the exhaled breath of a regular smoker was in vivo determined to be 5.8 pg mL(-1), without any sample pre-treatment. Our results show that EESI-ITMS is a powerful analytical platform to provide high sensitivity, high specificity and high throughput for semi-quantitative analysis of complex samples in life science, particularly for in vivo metabolomics studies.

  13. FEV manoeuvre induced changes in breath VOC compositions: an unconventional view on lung function tests

    NASA Astrophysics Data System (ADS)

    Sukul, Pritam; Schubert, Jochen K.; Oertel, Peter; Kamysek, Svend; Taunk, Khushman; Trefz, Phillip; Miekisch, Wolfram

    2016-06-01

    Breath volatile organic compound (VOC) analysis can open a non-invasive window onto pathological and metabolic processes in the body. Decades of clinical breath-gas analysis have revealed that changes in exhaled VOC concentrations are important rather than disease specific biomarkers. As physiological parameters, such as respiratory rate or cardiac output, have profound effects on exhaled VOCs, here we investigated VOC exhalation under respiratory manoeuvres. Breath VOCs were monitored by means of real-time mass-spectrometry during conventional FEV manoeuvres in 50 healthy humans. Simultaneously, we measured respiratory and hemodynamic parameters noninvasively. Tidal volume and minute ventilation increased by 292 and 171% during the manoeuvre. FEV manoeuvre induced substance specific changes in VOC concentrations. pET-CO2 and alveolar isoprene increased by 6 and 21% during maximum exhalation. Then they decreased by 18 and 37% at forced expiration mirroring cardiac output. Acetone concentrations rose by 4.5% despite increasing minute ventilation. Blood-borne furan and dimethyl-sulphide mimicked isoprene profile. Exogenous acetonitrile, sulphides, and most aliphatic and aromatic VOCs changed minimally. Reliable breath tests must avoid forced breathing. As isoprene exhalations mirrored FEV performances, endogenous VOCs might assure quality of lung function tests. Analysis of exhaled VOC concentrations can provide additional information on physiology of respiration and gas exchange.

  14. FEV manoeuvre induced changes in breath VOC compositions: an unconventional view on lung function tests

    PubMed Central

    Sukul, Pritam; Schubert, Jochen K.; Oertel, Peter; Kamysek, Svend; Taunk, Khushman; Trefz, Phillip; Miekisch, Wolfram

    2016-01-01

    Breath volatile organic compound (VOC) analysis can open a non-invasive window onto pathological and metabolic processes in the body. Decades of clinical breath-gas analysis have revealed that changes in exhaled VOC concentrations are important rather than disease specific biomarkers. As physiological parameters, such as respiratory rate or cardiac output, have profound effects on exhaled VOCs, here we investigated VOC exhalation under respiratory manoeuvres. Breath VOCs were monitored by means of real-time mass-spectrometry during conventional FEV manoeuvres in 50 healthy humans. Simultaneously, we measured respiratory and hemodynamic parameters noninvasively. Tidal volume and minute ventilation increased by 292 and 171% during the manoeuvre. FEV manoeuvre induced substance specific changes in VOC concentrations. pET-CO2 and alveolar isoprene increased by 6 and 21% during maximum exhalation. Then they decreased by 18 and 37% at forced expiration mirroring cardiac output. Acetone concentrations rose by 4.5% despite increasing minute ventilation. Blood-borne furan and dimethyl-sulphide mimicked isoprene profile. Exogenous acetonitrile, sulphides, and most aliphatic and aromatic VOCs changed minimally. Reliable breath tests must avoid forced breathing. As isoprene exhalations mirrored FEV performances, endogenous VOCs might assure quality of lung function tests. Analysis of exhaled VOC concentrations can provide additional information on physiology of respiration and gas exchange. PMID:27311826

  15. 16 CFR 1203.13 - Test schedule.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Test schedule. 1203.13 Section 1203.13... STANDARD FOR BICYCLE HELMETS The Standard § 1203.13 Test schedule. (a) Helmet sample 1 of the set of eight... environments, respectively) shall be tested in accordance with the dynamic retention system strength test at...

  16. Hyperbaric nitrogen prolongs breath-holding time in humans.

    PubMed

    Morooka, H; Wakasugi, Y; Shimamoto, H; Shibata, O; Sumikawa, K

    2000-09-01

    Either an increase in PaCO(2) or a decrease in PaO(2), can affect respiratory stimulation through respiratory centers, thus influencing breath-holding time (BHT). This study was designed to determine whether and how hyperbaric air could influence BHT in comparison with hyperbaric oxygen in humans. We studied 36 healthy volunteers in a multiplace hyperbaric chamber. BHT, pulse oximeter, and transcutaneous carbon dioxide tension were measured at 1 and 2.8 atmosphere absolute (ATA) in two groups. Group A (n = 20) breathed air. Group O (n = 16) breathed oxygen with a face mask (5 L/min). BHTs were 108 +/- 28 s at 1.0 ATA and 230 +/- 71 s at 2.8 ATA in Group A, and 137 +/- 48 s at 1.0 ATA and 180 +/- 52 s at 2.8 ATA in Group O. Transcutaneous carbon dioxide tension in Group A (59 +/- 2 mm Hg) was higher than that in Group O (54 +/- 2 mm Hg) at the end of maximal breath-holding at 2.8 ATA. The prolongation of BHT in hyperbaric air is significantly greater than that in hyperbaric oxygen. Breath-holding time is significantly prolonged in hyperbaric air than it is in hyperbaric oxygen. The mechanism involves the anesthetic effect of nitrogen suppressing the suffocating feeling during breath-holding.

  17. Dietary Protein Requirement of Men >65 Years Old Determined by the Indicator Amino Acid Oxidation Technique Is Higher than the Current Estimated Average Requirement.

    PubMed

    Rafii, Mahroukh; Chapman, Karen; Elango, Rajavel; Campbell, Wayne W; Ball, Ronald O; Pencharz, Paul B; Courtney-Martin, Glenda

    2016-03-09

    The current estimated average requirement (EAR) and RDA for protein of 0.66 and 0.8 g ⋅ kg -1 ⋅ d -1 , respectively, for adults, including older men, are based on nitrogen balance data analyzed by monolinear regression. Recent studies in young men and older women that used the indicator amino acid oxidation (IAAO) technique suggest that those values may be too low. This observation is supported by 2-phase linear crossover analysis of the nitrogen balance data. The main objective of this study was to determine the protein requirement for older men by using the IAAO technique. Six men aged >65 y were studied; each individual was tested 7 times with protein intakes ranging from 0.2 to 2.0 g ⋅ kg -1 ⋅ d -1 in random order for a total of 42 studies. The diets provided energy at 1.5 times the resting energy expenditure and were isocaloric. Protein was consumed hourly for 8 h as an amino acid mixture with the composition of egg protein with l-[1- 13 C]phenylalanine as the indicator amino acid. The group mean protein requirement was determined by applying a mixed-effects change-point regression analysis to F 13 CO 2 (label tracer oxidation in breath 13 CO 2 ), which identified a breakpoint in F 13 CO 2 in response to graded intakes of protein. The estimated protein requirement and RDA for older men were 0.94 and 1.24 g ⋅ kg -1 ⋅ d -1 , respectively, which are not different from values we published using the same method in young men and older women. The current intake recommendations for older adults for dietary protein of 0.66 g ⋅ kg -1 ⋅ d -1 for the EAR and 0.8 g ⋅ kg -1 ⋅ d -1 for the RDA appear to be underestimated by ∼30%. Future longer-term studies should be conducted to validate these results. This trial was registered at clinicaltrials.gov as NCT01948492. © 2016 American Society for Nutrition.

  18. Organic Gas Sensor with an Improved Lifetime for Detecting Breath Ammonia in Hemodialysis Patients.

    PubMed

    Chuang, Ming-Yen; Chen, Chang-Chiang; Zan, Hsiao-Wen; Meng, Hsin-Fei; Lu, Chia-Jung

    2017-12-22

    In this work, a TFB (poly[(9,9-dioctylfluorenyl-2,7-diyl)-co-(4,4'-(N-(4-s-butylphenyl)diphenylamine)]) sensor with a cylindrical nanopore structure exhibits a high sensitivity to ammonia in ppb-regime. The lifetime and sensitivity of the TFB sensor were studied and compared to those of P3HT (poly(3-hexylthiophene)), NPB (N,N'-di(1-naphthyl)-N,N'-diphenyl-(1,1'-biphenyl)-4,4'-diamine), and TAPC (4,4'-cyclohexylidenebis[N,N-bis(4-methylphenyl) benzenamine]) sensors with the same cylindrical nanopore structures. The TFB sensor outstands the others in sensitivity and lifetime and it shows a sensing response (current variation ratio) of 13% to 100 ppb ammonia after 64 days of storage in air. A repeated sensing periods testing and a long-term measurement have also been demonstrated for the test of robustness. The performance of the TFB sensor is stable in both tests, which reveals that the TFB sensor can be utilized in our targeting clinical trials. In the last part of this work, we study the change of ammonia concentration in the breath of hemodialysis (HD) patients before and after dialysis. An obvious drop of breath ammonia concentration can be observed after dialysis. The reduction of breath ammonia is also correlated with the reduction of blood urea nitrogen (BUN). A correlation coefficient of 0.82 is achieved. The result implies that TFB sensor may be used as a real-time and low cost breath ammonia sensor for the daily tracking of hemodialysis patients.

  19. TR-BREATH: Time-Reversal Breathing Rate Estimation and Detection.

    PubMed

    Chen, Chen; Han, Yi; Chen, Yan; Lai, Hung-Quoc; Zhang, Feng; Wang, Beibei; Liu, K J Ray

    2018-03-01

    In this paper, we introduce TR-BREATH, a time-reversal (TR)-based contact-free breathing monitoring system. It is capable of breathing detection and multiperson breathing rate estimation within a short period of time using off-the-shelf WiFi devices. The proposed system exploits the channel state information (CSI) to capture the miniature variations in the environment caused by breathing. To magnify the CSI variations, TR-BREATH projects CSIs into the TR resonating strength (TRRS) feature space and analyzes the TRRS by the Root-MUSIC and affinity propagation algorithms. Extensive experiment results indoor demonstrate a perfect detection rate of breathing. With only 10 s of measurement, a mean accuracy of can be obtained for single-person breathing rate estimation under the non-line-of-sight (NLOS) scenario. Furthermore, it achieves a mean accuracy of in breathing rate estimation for a dozen people under the line-of-sight scenario and a mean accuracy of in breathing rate estimation of nine people under the NLOS scenario, both with 63 s of measurement. Moreover, TR-BREATH can estimate the number of people with an error around 1. We also demonstrate that TR-BREATH is robust against packet loss and motions. With the prevailing of WiFi, TR-BREATH can be applied for in-home and real-time breathing monitoring.

  20. Diagnostic accuracy of the 14C-urea breath test in Helicobacter pylori infections: a meta-analysis.

    PubMed

    Zhou, Qiaohui; Li, Ling; Ai, Yaowei; Pan, Zhihong; Guo, Mingwen; Han, Jingbo

    2017-01-01

    To summarize and appraise the available literature regarding the use of the 14 C-urea breath test in the diagnosis of Helicobacter pylori infections in adult patients with dyspepsia and to calculate pooled diagnostic accuracy measures. We systematically searched the PubMed, EMBASE, Cochrane Library, Chinese Journals Full-text (CNKI) and CBMDisc databases to identify published data regarding the sensitivity, specificity, and other measures of diagnostic accuracy of the 14 C-urea breath test in the diagnosis of Helicobacter pylori infections in adult patients with dyspeptic symptoms. Risk of bias was assessed using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies)-2 tool. Statistical analyses were performed using Meta-Disc 1.4 software and STATA. Eighteen studies met the inclusion criteria. Pooled results indicated that the  14 C-urea breath test showed a diagnostic sensitivity of 0.96 (95% CI 0.95 to 0.96) and specificity of 0.93 (95% CI 0.91 to 0.94). The positive like ratio (PLR) was 12.27 (95% CI 8.17 to 18.44), the negative like ratio (NLR) was 0.05 (95% CI 0.04 to 0.07), and the area under the curve was 0.985. The DOR was 294.95 (95% CI 178.37 to 487.70). The 14 C-urea breath test showed sufficient sensitivity and specificity for diagnosing Helicobacter pylori infection, but unexplained heterogeneity after meta-regression and several subgroup analyses remained. The UBT has high accuracy for diagnosing H. pylori infections in adult patients with dyspepsia. However, the reliability of these diagnostic meta-analytic estimates is limited by significant heterogeneity due to unknown factors.

  1. Qualitative assessment of contrast-enhanced magnetic resonance angiography using breath-hold and non-breath-hold techniques in the portal venous system

    NASA Astrophysics Data System (ADS)

    Goo, Eun-Hoe; Kim, Sun-Ju; Dong, Kyung-Rae; Kim, Kwang-Choul; Chung, Woon-Kwan

    2016-09-01

    The purpose of this study is to evaluate the image quality in delineation of the portal venous systems with two different methods, breath-hold and non-breath-hold by using the 3D FLASH sequence. We used a 1.5 T system to obtain magnetic resonance(MR)images. Arterial and portal phase 3D FLASH images were obtained with breath-hold after a bolus injection of GD-DOTA. The detection of PVS on the MR angiograms was classified into three grades. First, the angiograms of the breath-hold method showed well the portal vein, the splenic vein and the superior mesenteric vein systems in 13 of 15 patients (86%) and the inferior mesenteric vein system in 6 of 15 patients (40%), Second, MR angiograms of the non-breath-hold method demonstrated the PVS and the SMV in 12 of 15 patients (80%) and the IMV in 5 of 15 patients (33%). Our study showed contrast-enhanced 3D FLASH MR angiography, together with the breath-hold technique, may provide reliable and accurate information on the portal venous system.

  2. Micropreconcentrator in LTCC Technology with Mass Spectrometry for the Detection of Acetone in Healthy and Type-1 Diabetes Mellitus Patient Breath

    PubMed Central

    Rydosz, Artur

    2014-01-01

    Breath analysis has long been recognized as a potentially attractive method for the diagnosis of several diseases. The main advantage over other diagnostic methods such as blood or urine analysis is that breath analysis is fully non-invasive, comfortable for patients and breath samples can be easily obtained. One possible future application of breath analysis may be the diagnosing and monitoring of diabetes. It is, therefore, essential, to firstly determine a relationship between exhaled biomarker concentration and glucose in blood as well as to compare the results with the results obtained from non-diabetic subjects. Concentrations of molecules which are biomarkers of diseases’ states, or early indicators of disease should be well documented, i.e., the variations of abnormal concentrations of breath biomarkers with age, gender and ethnic issues need to be verified. Furthermore, based on performed measurements it is rather obvious that analysis of exhaled acetone as a single biomarker of diabetes is unrealistic. In this paper, the author presents results of his research conducted on samples of breath gas from eleven healthy volunteers (HV) and fourteen type-1 diabetic patients (T1DM) which were collected in 1-l SKC breath bags. The exhaled acetone concentration was measured using mass spectrometry (HPR-20 QIC, Hiden Analytical, Warrington, UK) coupled with a micropreconcentrator in LTCC (Low Temperature Cofired Ceramic). However, as according to recent studies the level of acetone varies to a significant extent for each blood glucose concentration of single individuals, a direct and absolute relationship between blood glucose and acetone has not been proved. Nevertheless, basing on the research results acetone in diabetic breath was found to be higher than 1.11 ppmv, while its average concentration in normal breath was lower than 0.83 ppmv. PMID:25310087

  3. Quiet breathing in hindlimb casted mice.

    PubMed

    Receno, Candace N; Roffo, Katelynn E; Mickey, Marisa C; DeRuisseau, Keith C; DeRuisseau, Lara R

    2018-06-07

    The hindlimb casting model was developed to study skeletal muscle reloading following a period of unloading. It is unknown if ventilation parameters of mice are affected by the casting model. We tested the hypothesis that hindlimb casted mice have similar ventilatory patterns compared to mice with the casts removed. Male CD-1 mice underwent 14 days of hindlimb immobilization via plaster casting. Breathing parameters were obtained utilizing unrestrained barometric plethysmography (UBP). Breathing traces were analyzed with Ponemah software for breathing frequency, tidal volume (TV), and minute ventilation (MV). Frequency, TV and MV did not show any differences in quiet breathing patterns during or post-casting in mice. Thus, the hindlimb casting model does not complicate breathing during and after casting and should not interfere with the unloading and reloading of skeletal muscle. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Air-breathing behavior, oxygen concentrations, and ROS defense in the swimbladders of two erythrinid fish, the facultative air-breathing jeju, and the non-air-breathing traira during normoxia, hypoxia and hyperoxia.

    PubMed

    Pelster, Bernd; Wood, Chris M; Jung, Ellen; Val, Adalberto L

    2018-05-01

    The jeju Hoplerythrinus unitaeniatus and the traira Hoplias malabaricus are two neighboring genera from the family of erythrinid fish, both possessing a two-chambered physostomous swimbladder. In the jeju the anterior section of the posterior bladder is highly vascularized, and the swimbladder is used for aerial respiration; the traira, in turn, is a water-breather that uses the swimbladder as a buoyancy organ and not for aerial oxygen uptake. Measurement of swimbladder oxygen partial pressure (PO 2 ) of fish kept at 26 °C in normoxic, hyperoxic (28-32 mg O 2 L - 1 ) or hypoxic (1-1.5 mg O 2 L - 1 ) water revealed constant values in traira swimbladder. Under normoxic conditions in the jeju swimbladder PO 2 was higher than in traira, and the PO 2 significantly increased under hyperoxic conditions, even in the absence of air breathing. In jeju, air-breathing activity increased significantly under hypoxic conditions. Hypoxic air-breathing activity was negatively correlated to swimbladder PO 2 , indicating that the swimbladder was intensely used for gas exchange under these conditions. In traira, the capacity of the ROS defense system, as assessed by measurement of activities of enzymes involved in ROS degradation and total glutathione (GSH + GSSG) concentration, was elevated after 4 h of hyperoxic and/or hypoxic exposure, although swimbladder PO 2 was not affected. In jeju, experiencing a higher variability in swimbladder PO 2 due to the air-breathing activity, only a reduced responsiveness of the ROS defense system to changing environmental PO 2 was detected.

  5. Determination of lithium and transition metals in Li1 Ni1/3 Co1/3 Mn1/3 O2 (NCM) cathode material for lithium-ion batteries by capillary electrophoresis.

    PubMed

    Vortmann-Westhoven, Britta; Lürenbaum, Constantin; Winter, Martin; Nowak, Sascha

    2017-02-01

    In this work, we present a novel electrophoretic method that was developed for the determination of lithium and transition metals in LiNi 1/3 Co 1/3 Mn 1/3 O 2 cathode material after microwave digestion. The cations in the digested LiNi 1/3 Co 1/3 Mn 1/3 O 2 material were separated by CE and the element content was determined by UV/Vis detection. To characterize the precision of the measurements, the RSDs and concentrations were calculated and compared to those obtained with ICP-optical emission spectrometry (ICP-OES). Furthermore, a certified reference material (BCR 176R-fly ash) was investigated for all techniques. For active material components, the LOD and LOQ were determined. The LODs and LOQs for the metals determined by CE were as follows: lithium (LOD/LOQ): 17.41/62.70 μg/L, cobalt (LOD/LOQ): 348.4/1283 μg/L, manganese (LOD/LOQ): 540.2/2095 μg/L, and nickel (LOD/LOQ): 838.0/2982 μg/L. Recovery rates for lithium were in the range of 95-103%. It could be proven that with the new technique, the results for the determination of the lithium content of active material were comparable with those obtained by ICP-OES and ion chromatography. Furthermore, the recovery rates of the transition metals were determined to be between 96 and 110% by CE and ICP-OES. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Updating prognosis of cirrhosis by Cox's regression model using Child-Pugh score and aminopyrine breath test as time-dependent covariates.

    PubMed

    Merkel, C; Morabito, A; Sacerdoti, D; Bolognesi, M; Angeli, P; Gatta, A

    1998-06-01

    The determination of aminopyrine breath test on entry into the study was recently shown to improve the accuracy of prediction of death based on the Child-Pugh classification, but the possible usefulness of serial determinations of both parameters has not been assessed. In the present study, we aimed at evaluating whether serial determinations of aminopyrine breath test and Child-Pugh score improve prognostic accuracy in patients with cirrhosis, compared with determinations obtained only on admission. In 74 patients with liver cirrhosis aminopyrine breath test and Child-Pugh score were obtained upon entry into the study. Patients were followed with sequential aminopyrine breath tests and assessments of the Child-Pugh score every 4-6 months. A total number of 232 determinations were obtained. During follow-up 45 patients died, on average after 12 months of follow-up. Child-Pugh score improved in the beginning of follow-up, and then remained fairly constant; aminopyrine breath test showed no improvement in the beginning of follow-up, but rather a slowly progressive decline. In patients who died, both the Child-Pugh score and the metabolism of aminopyrine were significantly more impaired in the last year preceding death (p < 0.05). Applying Cox's regression model with time-dependent covariates, Child-Pugh score and aminopyrine breath test were independent significant predictors of survival. The model with time-dependent covariates explained the observed survival much better than the model with time-fixed covariates (chi-sq. explained by regression = 31.45 vs 11.97; d.f. = 2; p = 0.0000001 vs 0.003). These data suggest that serial determinations of Child-Pugh score and aminopyrine breath test can be used to efficiently update prognosis of cirrhosis.

  7. Comparison between hyperventilation and breath-holding in panic disorder: patients responsive and non-responsive to both tests.

    PubMed

    Nardi, Antonio E; Valença, Alexandre M; Mezzasalma, Marco A; Levy, Sandra P; Lopes, Fabiana L; Nascimento, Isabella; Freire, Rafael C; Veras, Andre B; Zin, Walter A

    2006-06-15

    Our aim was to compare the demographic and psychopathological features of panic disorder (PD) patients who underwent hyperventilation and breath-holding challenge tests, and to describe the features of patients who had a panic attack after both tests versus those patients who did not experience panic after either test. Eighty-five PD patients were induced to hyperventilate (30 breaths/min) for 4 min, and a week later to hold their breath for as long as possible four times with a 2-min interval in between. Anxiety scales were applied before and after the tests. Patients who responded with a panic attack to both tests (BPA, n = 25) were compared with patients who experienced spontaneous panic attacks but did not panic in response to the two tests (NPA, n = 16). The BPA group had a significantly higher presence of respiratory symptoms during a panic attack. The criteria for the respiratory PD subtype were fulfilled in 18 (72.0%) BPA patients and in 6 (37.5%) NPA patients. The BPA patients had a later onset of panic disorder and a higher familial prevalence of PD. Our data suggest that there is a distinction between PD patients who were sensitive to both hyperventilation and breath-holding tests and PD patients who were not affected by the challenge tests. The panic attack may be a final common pathway for different types of stimuli, and respiratory tests may characterize different PD subgroups.

  8. News from the Breath Analysis Summit 2011.

    PubMed

    Corradi, Massimo; Mutti, Antonio

    2012-06-01

    This special section highlights some of the important work presented at the Breath Analysis Summit 2011, which was held in Parma (Italy) from 11 to 14 September 2011. The meeting, which was jointly organized by the International Association for Breath Research and the University of Parma, was attended by more than 250 delegates from 33 countries, and offered 34 invited lectures and 64 unsolicited scientific contributions. The summit was organized to provide a forum to scientists, engineers and clinicians to present their latest findings and to meet industry executives and entrepreneurs to discuss key trends, future directions and technologies available for breath analysis. A major focus was on nitric oxide, exhaled breath condensate, electronic nose, mass spectrometry and newer sensor technologies. Medical applications ranged from asthma and other respiratory diseases to gastrointestinal disease, occupational diseases, critical care and cancer. Most people identify breath tests with breathalysers used by police to estimate ethanol concentration in blood. However, breath testing has far more sophisticated applications. Breath analysis is rapidly evolving as a new frontier in medical testing for disease states in the lung and beyond. Every individual has a breath fingerprint-or 'breathprint'-that can provide useful information about his or her state of health. This breathprint comprises the many thousands of molecules that are expelled with each breath we exhale. Breath research in the past few years has uncovered the scientific and molecular basis for such clinical observations. Relying on mass spectrometry, we have been able to identify many such unique substances in exhaled breath, including gases, such as nitric oxide (NO) and carbon monoxide (CO), and a wide array of volatile organic compounds. Exhaled breath also carries aerosolized droplets that can be collected as an exhaled breath condensate that contains endogenously produced non-volatile compounds. Breath

  9. Functional Properties of a Newly Identified C-terminal Splice Variant of Cav1.3 L-type Ca2+ Channels*

    PubMed Central

    Bock, Gabriella; Gebhart, Mathias; Scharinger, Anja; Jangsangthong, Wanchana; Busquet, Perrine; Poggiani, Chiara; Sartori, Simone; Mangoni, Matteo E.; Sinnegger-Brauns, Martina J.; Herzig, Stefan; Striessnig, Jörg; Koschak, Alexandra

    2011-01-01

    An intramolecular interaction between a distal (DCRD) and a proximal regulatory domain (PCRD) within the C terminus of long Cav1.3 L-type Ca2+ channels (Cav1.3L) is a major determinant of their voltage- and Ca2+-dependent gating kinetics. Removal of these regulatory domains by alternative splicing generates Cav1.342A channels that activate at a more negative voltage range and exhibit more pronounced Ca2+-dependent inactivation. Here we describe the discovery of a novel short splice variant (Cav1.343S) that is expressed at high levels in the brain but not in the heart. It lacks the DCRD but, in contrast to Cav1.342A, still contains PCRD. When expressed together with α2δ1 and β3 subunits in tsA-201 cells, Cav1.343S also activated at more negative voltages like Cav1.342A but Ca2+-dependent inactivation was less pronounced. Single channel recordings revealed much higher channel open probabilities for both short splice variants as compared with Cav1.3L. The presence of the proximal C terminus in Cav1.343S channels preserved their modulation by distal C terminus-containing Cav1.3- and Cav1.2-derived C-terminal peptides. Removal of the C-terminal modulation by alternative splicing also induced a faster decay of Ca2+ influx during electrical activities mimicking trains of neuronal action potentials. Our findings extend the spectrum of functionally diverse Cav1.3 L-type channels produced by tissue-specific alternative splicing. This diversity may help to fine tune Ca2+ channel signaling and, in the case of short variants lacking a functional C-terminal modulation, prevent excessive Ca2+ accumulation during burst firing in neurons. This may be especially important in neurons that are affected by Ca2+-induced neurodegenerative processes. PMID:21998310

  10. Breath analysis with broadly tunable quantum cascade lasers.

    PubMed

    Wörle, Katharina; Seichter, Felicia; Wilk, Andreas; Armacost, Chris; Day, Tim; Godejohann, Matthias; Wachter, Ulrich; Vogt, Josef; Radermacher, Peter; Mizaikoff, Boris

    2013-03-05

    With the availability of broadly tunable external cavity quantum cascade lasers (EC-QCLs), particularly bright mid-infrared (MIR; 3-20 μm) light sources are available offering high spectral brightness along with an analytically relevant spectral tuning range of >2 μm. Accurate isotope ratio determination of (12)CO2 and (13)CO2 in exhaled breath is of critical importance in the field of breath analysis, which may be addressed via measurements in the MIR spectral regime. Here, we combine for the first time an EC-QCL tunable across the (12)CO2/(13)CO2 spectral band with a miniaturized hollow waveguide gas cell for quantitatively determining the (12)CO2/(13)CO2 ratio within the exhaled breath of mice. Due to partially overlapping spectral features, these studies are augmented by appropriate multivariate data evaluation and calibration techniques based on partial least-squares regression along with optimized data preprocessing. Highly accurate determinations of the isotope ratio within breath samples collected from a mouse intensive care unit validated via hyphenated gas chromatography-mass spectrometry confirm the viability of IR-HWG-EC-QCL sensing techniques for isotope-selective exhaled breath analysis.

  11. The likelihood of acetone interference in breath alcohol measurement

    DOT National Transportation Integrated Search

    1985-09-01

    This report discusses the significance of possible interference of acetone in breath alcohol testing. The following dimensions were considered: 1) what levels of acetone concentration may appear on the breath; 2) what levels of acetone concentration ...

  12. A comparison of standard inhalers for asthma with and without alcohol as the propellant on the measurement of alcohol in breath.

    PubMed

    Ignacio-García, José M; Ignacio-García, Juan M; Almenara-Barrios, José; Chocrón-Giraldez, María J; Hita-Iglesias, Carmen

    2005-01-01

    Because most bronchodilator inhalers contain propellant gases or a small amount of ethanol as a co-solvent, the potential for these products to generate false readings on a evidential breath alcohol instrument was evaluated in 69 volunteers with clinically stable asthma. All subjects underwent a breath test on an infrared breath alcohol analyzer (Alcotest 7110, Dräger, Lübeck, Germany) before the use of the asthma inhaler and 1 and 5 min after inhalation. The effects of antiasthmatic medications delivered by metered dose inhalers (MDIs) with alcohol as a vehicle, alcohol-free MDIs, and dry powder inhalers were assessed in homogeneous groups of four to five patients. All subjects were alcohol-free on the preliminary breath test. One minute after inhalation, negative readings were only observed in 25 (36.2%) of subjects. In 62.3% of patients, apparent alcohol results were considered interferences or unstable readings by the breath-test instrument. One subject showed a final positive breath alcohol level (0.07 mg/L). After the use of dry powder inhalers, valid results without interferences were obtained. However, 89.6% of patients in which bronchodilators were delivered by MDIs (with propellant gases in the aerosol) showed altered partial readings and labeled the final output as "invalid," but tests performed 5 min after the use of inhalers were valid and correct in all cases. MDIs with propellants as a vehicle may cause false positive breath alcohol readings in some patients. These effects are transient and may be prevented by a 5-10-min interval between the use of MDIs and breath alcohol testing.

  13. Layered oxides-LiNi1/3Co1/3Mn1/3O2 as anode electrode for symmetric rechargeable lithium-ion batteries

    NASA Astrophysics Data System (ADS)

    Wang, Yuesheng; Feng, Zimin; Yang, Shi-Ze; Gagnon, Catherine; Gariépy, Vincent; Laul, Dharminder; Zhu, Wen; Veillette, René; Trudeau, Michel L.; Guerfi, Abdelbast; Zaghib, Karim

    2018-02-01

    High-performance and long-cycling rechargeable lithium-ion batteries have been in steadily increasing demand for the past decades. Nevertheless, the two dominant anodes at the moment, graphite and L4T5O12, suffer from a safety issue of lithium plating (operating voltage at ∼ 0.1 V vs. Li+/Li) and low capacity (175 mAh/g), respectively. Here, we report LiNi1/3Co1/3Mn1/3O2 as an alternative anode material which has a working voltage of ∼1.1 V and a capacity as high as 330 mAh/g at the current rate of C/15. Symmetric cells with both electrodes containing LiNi1/3Co1/3Mn1/3O2 can deliver average discharge voltage of 2.2 V. In-situ XRD, HRTEM and first principles calculations indicate that the reaction mechanism of a LiNi1/3Co1/3Mn1/3O2 anode is comprised mainly of conversion. Both the fundamental understanding and practical demonstrations suggest that LiNi1/3Co1/3Mn1/3O2 is a promising negative electrode material for lithium-ion batteries.

  14. Quantifying Aerosol Delivery in Simulated Spontaneously Breathing Patients With Tracheostomy Using Different Humidification Systems With or Without Exhaled Humidity.

    PubMed

    Ari, Arzu; Harwood, Robert; Sheard, Meryl; Alquaimi, Maher Mubarak; Alhamad, Bshayer; Fink, James B

    2016-05-01

    Aerosol and humidification therapy are used in long-term airway management of critically ill patients with a tracheostomy. The purpose of this study was to determine delivery efficiency of jet and mesh nebulizers combined with different humidification systems in a model of a spontaneously breathing tracheotomized adult with or without exhaled heated humidity. An in vitro model was constructed to simulate a spontaneously breathing adult (tidal volume, 400 mL; breathing frequency, 20 breaths/min; inspiratory-expiratory ratio, 1:2) with a tracheostomy using a teaching manikin attached to a test lung through a collecting filter (Vital Signs Respirgard II). Exhaled heat and humidity were simulated using a cascade humidifier set to deliver 37°C and >95% relative humidity. Albuterol sulfate (2.5 mg/3 mL) was administered with a jet nebulizer (AirLife Misty Max) operated at 10 L/min and a mesh nebulizer (Aeroneb Solo) using a heated pass-over humidifier, unheated large volume humidifier both at 40 L/min output and heat-and-moisture exchanger. Inhaled drug eluted from the filter was analyzed via spectrophotometry (276 nm). Delivery efficiency of the jet nebulizer was less than that of the mesh nebulizer under all conditions (P < .05). Aerosol delivery with each nebulizer was greatest on room air and lowest when heated humidifiers with higher flows were used. Exhaled humidity decreased drug delivery up to 44%. The jet nebulizer was less efficient than the mesh nebulizer in all conditions tested in this study. Aerosol deposition with each nebulizer was lowest with the heated humidifier with high flow. Exhaled humidity reduced inhaled dose of drug compared with a standard model with nonheated/nonhumidified exhalation. Further clinical research is warranted to understand the impact of exhaled humidity on aerosol drug delivery in spontaneously breathing patients with tracheostomy using different types of humidifiers. Copyright © 2016 by Daedalus Enterprises.

  15. Dietary protein requirement of female adults >65 years determined by the indicator amino acid oxidation technique is higher than current recommendations.

    PubMed

    Rafii, Mahroukh; Chapman, Karen; Owens, Jillian; Elango, Rajavel; Campbell, Wayne W; Ball, Ronald O; Pencharz, Paul B; Courtney-Martin, Glenda

    2015-01-01

    Studies on protein requirements in vulnerable groups such as older adults are few, and results are conflicting. The main objective of this study was to determine the protein requirements of free-living women >65 y by measuring the oxidation of l-[1-(13)C]phenylalanine to (13)CO2 in response to graded intakes of protein. Twelve subjects participated in the study, with protein intakes ranging from 0.2 to 2.0 g · kg(-1) · d(-1) for a total of 82 studies. The diets provided energy at 1.5 times each subject's resting energy expenditure and were isocaloric. Protein was given as an amino acid mixture on the basis of the egg protein pattern, except for phenylalanine and tyrosine, which were maintained constant across the protein intake amounts. All subjects were adapted for 2 d before the study day to a protein intake of 1.0 g · kg(-1) · d(-1). The mean protein requirement was determined by applying a mixed-effects change-point regression analysis to F(13)CO2 (label tracer oxidation in (13)CO2 breath), which identified a breakpoint in the F(13)CO2 in response to graded amounts of protein. The mean estimated average requirement (EAR) and upper 95% CI (approximating the RDA) protein requirement of women >65 y were 0.96 and 1.29 g · kg(-1) · d(-1), respectively. These estimates of protein requirements for older women are higher than the current EAR and RDA based on nitrogen balance data, which are 0.66 and 0.80 g · kg(-1) · d(-1), respectively. This trial was registered at clinicaltrials.gov as NCT01604980. © 2015 American Society for Nutrition.

  16. Effects of breathing frequency and flow rate on the total inward leakage of an elastomeric half-mask donned on an advanced manikin headform.

    PubMed

    He, Xinjian; Grinshpun, Sergey A; Reponen, Tiina; McKay, Roy; Bergman, Michael S; Zhuang, Ziqing

    2014-03-01

    The objective of this study was to investigate the effects of breathing frequency and flow rate on the total inward leakage (TIL) of an elastomeric half-mask donned on an advanced manikin headform and challenged with combustion aerosols. An elastomeric half-mask respirator equipped with P100 filters was donned on an advanced manikin headform covered with life-like soft skin and challenged with aerosols originated by burning three materials: wood, paper, and plastic (polyethylene). TIL was determined as the ratio of aerosol concentrations inside (C in) and outside (C out) of the respirator (C in/C out) measured with a nanoparticle spectrometer operating in the particle size range of 20-200nm. The testing was performed under three cyclic breathing flows [mean inspiratory flow (MIF) of 30, 55, and 85 l/min] and five breathing frequencies (10, 15, 20, 25, and 30 breaths/min). A completely randomized factorial study design was chosen with four replicates for each combination of breathing flow rate and frequency. Particle size, MIF, and combustion material had significant (P < 0.001) effects on TIL regardless of breathing frequency. Increasing breathing flow decreased TIL. Testing with plastic aerosol produced higher mean TIL values than wood and paper aerosols. The effect of the breathing frequency was complex. When analyzed using all combustion aerosols and MIFs (pooled data), breathing frequency did not significantly (P = 0.08) affect TIL. However, once the data were stratified according to combustion aerosol and MIF, the effect of breathing frequency became significant (P < 0.05) for all MIFs challenged with wood and paper combustion aerosols, and for MIF = 30 l/min only when challenged with plastic combustion aerosol. The effect of breathing frequency on TIL is less significant than the effects of combustion aerosol and breathing flow rate for the tested elastomeric half-mask respirator. The greatest TIL occurred when challenged with plastic aerosol at 30 l/min and

  17. Breath-to-breath hypercapnic response in neonatal rats: temperature dependency of the chemoreflexes and potential implications for breathing stability.

    PubMed

    Cummings, Kevin J; Frappell, Peter B

    2009-07-01

    The breathing of newborns is destabilized by warm temperatures. We hypothesized that in unanesthetized, intact newborn rats, body temperature (T(B)) influences the peripheral chemoreflex response (PCR response) to hypercapnia. To test this, we delivered square-wave challenges of 8% CO(2) in air to postnatal day 4-5 (P4-P5) rats held at a T(B) of 30 degrees C (Cold group, n = 11), 33 degrees C (Cool group, n = 10), and 35 degrees C thermoneutral zone group [thermoneutral zone (TNZ) group, n = 11], while measuring ventilation (Ve) directly with a pneumotach and mask. Cool animals were challenged with 8% CO(2) balanced in either air or hyperoxia (n = 10) to identify the PCR response. Breath-to-breath analysis was performed on 30 room air breaths and every breath of the 1-min CO(2) challenge. As expected, warmer T(B) was associated with an unstable breathing pattern in room air: TNZ animals had a coefficient of variation in Ve (Ve CV%) that was double that of animals held at cooler T(B) (P < 0.001). Hyperoxia markedly suppressed the hypercapnic ventilatory response over the first 10 breaths (or approximately 4 s), suggesting that this domain is dominated by the PCR response. The PCR response (P = 0.03) and total response (P = 0.04) were significantly greater in TNZ animals compared with hypothermic animals. The total response had a significant, negative relationship with Vco(2) (R(2) = 0.53; P < 0.001). Breathing stability was positively related to the total response (R(2) = 0.36; P < 0.001) and to a lesser extent, the PCR response (R(2) = 0.19; P = 0.01) and was negatively related to Vco(2) (R(2) = 0.34; P < 0.001). ANCOVA confirmed a significant effect of T(B) alone on breathing stability (P < 0.01), with no independent effects of Vco(2) (P = 0.41), the PCR response (P = 0.82), or the total Ve response (P = 0.08). Our data suggest that in early postnatal life, the chemoreflex responses to CO(2) are highly influenced by T(B), and while related to breathing stability

  18. Effects of Lung Volume Reduction Surgery on Gas Exchange and Breathing Pattern During Maximum Exercise

    PubMed Central

    Criner, Gerard J.; Belt, Patricia; Sternberg, Alice L.; Mosenifar, Zab; Make, Barry J.; Utz, James P.; Sciurba, Frank

    2009-01-01

    Background: The National Emphysema Treatment Trial studied lung volume reduction surgery (LVRS) for its effects on gas exchange, breathing pattern, and dyspnea during exercise in severe emphysema. Methods: Exercise testing was performed at baseline, and 6, 12, and 24 months. Minute ventilation (V̇e), tidal volume (Vt), carbon dioxide output (V̇co2), dyspnea rating, and workload were recorded at rest, 3 min of unloaded pedaling, and maximum exercise. Pao2, Paco2, pH, fraction of expired carbon dioxide, and bicarbonate were also collected in some subjects at these time points and each minute of testing. There were 1,218 patients enrolled in the study (mean [± SD] age, 66.6 ± 6.1 years; mean, 61%; mean FEV1, 0.77 ± 0.24 L), with 238 patients participating in this substudy (mean age, 66.1 ± 6.8 years; mean, 67%; mean FEV1, 0.78 ± 0.25 L). Results: At 6 months, LVRS patients had higher maximum V̇e (32.8 vs 29.6 L/min, respectively; p = 0.001), V̇co2, (0.923 vs 0.820 L/min, respectively; p = 0.0003), Vt (1.18 vs 1.07 L, respectively; p = 0.001), heart rate (124 vs 121 beats/min, respectively; p = 0.02), and workload (49.3 vs 45.1 W, respectively; p = 0.04), but less breathlessness (as measured by Borg dyspnea scale score) [4.4 vs 5.2, respectively; p = 0.0001] and exercise ventilatory limitation (49.5% vs 71.9%, respectively; p = 0.001) than medical patients. LVRS patients with upper-lobe emphysema showed a downward shift in Paco2 vs V̇co2 (p = 0.001). During exercise, LVRS patients breathed slower and deeper at 6 months (p = 0.01) and 12 months (p = 0.006), with reduced dead space at 6 months (p = 0.007) and 24 months (p = 0.006). Twelve months after patients underwent LVRS, dyspnea was less in patients with upper-lobe emphysema (p = 0.001) and non–upper-lobe emphysema (p = 0.007). Conclusion: During exercise following LVRS, patients with severe emphysema improve carbon dioxide elimination and dead space, breathe slower and deeper, and report less dyspnea

  19. Detection of nitric oxide in exhaled human breath: exercise and resting determinations.

    PubMed

    Mantione, Kirk J; Esch, Tobias; Stefano, George B

    2007-03-01

    Nitric oxide has become a vital indicator of health since many cells produce it constitutively. It is present in exhaled breath and can be measured. A Kiernan NO Breath analyzer (KNB) was used in the present study to determine nitric oxide (NO) levels in exhaled human breath. The KNB was calibrated via measuring NO gas in O2-free N2 obtained from Scott Specialty Gases. Human subjects aged 21 to 45 were instructed to place the KNB over their nose and mouth and to breathe normally before and after mild exercise (n=24) and relaxation (n=20). Mean exhaled NO measurements were compared before and after the protocols using paired t-tests. Regardless of the test, all subjects exhibited NO in their exhaled breath. Exhaled NO decreased significantly after exercise compared to the first reading just prior to the exercise protocol. The mean +/-SE of exhaled NO was 22.8+/-4 before and 13.0+/-2 ppb after exercise (n=24, P=0.003). In the resting experiment, exhaled NO was demonstrated to increase significantly after 10 min compared to the reading taken right after the individuals sat down. The present study demonstrates NO in exhaled human breath can vary, reflecting the activity state of the individual. Additionally, the study demonstrates that NO in exhaled human breath can be measured rapidly, with high sensitivity, and in real time via the KNB, representing an affordable means to achieve this determination.

  20. Value of the 13C-urea breath test for detection of gastric Helicobacter spp. infection in dogs undergoing endoscopic examination.

    PubMed

    Kubota, Sanae; Ohno, Koichi; Tsukamoto, Atsushi; Maeda, Shingo; Murata, Yosuke; Nakashima, Ko; Fukushima, Kenjiro; Uchida, Kazuyuki; Fujino, Yasuhito; Tsujimoto, Hajime

    2013-01-01

    Urea breath test (UBT) using an infrared spectral analyzer is widely used for non-invasive and rapid detection of gastric Helicobacter spp. in human, but not veterinary medicine. The main purposes of this study were to determine the reference range of the UBT in dogs and to evaluate its clinical usefulness. To address the first aim, 6 healthy laboratory beagles were subjected to UBT and upper gastrointestinal endoscopy. Gastric endoscopic biopsy samples from the antrum, corpus and fundus were examined for Helicobacter spp. by polymerase chain reaction (PCR) testing, rapid urease test (RUT), histology and cytology. Amoxicillin, metronidazole and omeprazole were given to infected dogs for 14 days, and dogs that became Helicobacter-negative were used to determine the reference range for UBT. To address the second aim, 32 canine patients underwent UBT before upper gastrointestinal endoscopy, and the sensitivity and specificity of UBT were calculated based on our newly determined reference range using PCR as the gold standard for detection of Helicobacter spp. Initially, all 6 laboratory beagles were infected in all gastric regions and became uninfected after eradication. The mean ± 2 SD UBT value after eradication was 0.6 ± 1.8‰, and the reference range for UBT was determined to be less than 2.5‰. UBT was completed successfully in 27 patients. Using our reference range, UBT displayed 89% (16/18) sensitivity and 89% (8/9) specificity, indicating that UBT was quite useful for the detection of gastric Helicobacter spp. infection in dogs.

  1. Adenosine A(1) receptors in mouse pontine reticular formation depress breathing, increase anesthesia recovery time, and decrease acetylcholine release.

    PubMed

    Gettys, George C; Liu, Fang; Kimlin, Ed; Baghdoyan, Helen A; Lydic, Ralph

    2013-02-01

    Clinical and preclinical data demonstrate the analgesic actions of adenosine. Central administration of adenosine agonists, however, suppresses arousal and breathing by poorly understood mechanisms. This study tested the two-tailed hypothesis that adenosine A1 receptors in the pontine reticular formation (PRF) of C57BL/6J mice modulate breathing, behavioral arousal, and PRF acetylcholine release. Three sets of experiments used 51 mice. First, breathing was measured by plethysmography after PRF microinjection of the adenosine A1 receptor agonist N-sulfophenyl adenosine (SPA) or saline. Second, mice were anesthetized with isoflurane and the time to recovery of righting response (RoRR) was quantified after a PRF microinjection of SPA or saline. Third, acetylcholine release in the PRF was measured before and during microdialysis delivery of SPA, the adenosine A1 receptor antagonist 1, 3-dipropyl-8-cyclopentylxanthine, or SPA and 1, 3-dipropyl-8-cyclopentylxanthine. First, SPA significantly decreased respiratory rate (-18%), tidal volume (-12%), and minute ventilation (-16%). Second, SPA concentration accounted for 76% of the variance in RoRR. Third, SPA concentration accounted for a significant amount of the variance in acetylcholine release (52%), RoRR (98%), and breathing rate (86%). 1, 3-dipropyl-8-cyclopentylxanthine alone caused a concentration-dependent increase in acetylcholine, a decrease in RoRR, and a decrease in breathing rate. Coadministration of SPA and 1, 3-dipropyl-8-cyclopentylxanthine blocked the SPA-induced decrease in acetylcholine and increase in RoRR. Endogenous adenosine acting at adenosine A1 receptors in the PRF modulates breathing, behavioral arousal, and acetylcholine release. The results support the interpretation that an adenosinergic-cholinergic interaction within the PRF comprises one neurochemical mechanism underlying the wakefulness stimulus for breathing.

  2. Breathing metabolic simulator.

    NASA Technical Reports Server (NTRS)

    Bartlett, R. G., Jr.; Hendricks, C. M.; Morison, W. B.

    1971-01-01

    Description of a device for simulation of the human breathing and metabolic parameters required for the evaluation of respiratory diagnostic, monitoring, support and resuscitation equipment. The remotely controlled device allows wide variations in breathing rate and depth, breath velocity contour, oxygen uptake and carbon dioxide release to simulate conditions from sleep to hard work, with respiration exchange ratios ranging from hypoventilation to hyperventilation. It also reduces the cost of prolonged testing when simulation chambers with human subjects require three shifts of crews and standby physicians. Several block diagrams of the device and subsystems are given.

  3. Delivery of helium–oxygen mixture during spontaneous breathing: evaluation of three high-concentration face masks.

    PubMed

    Roche-Campo, Ferran; Vignaux, Laurence; Galia, Fabrice; Lyazidi, Aissam; Vargas, Frédéric; Texereau, Joëlle; Apiou-Sbirlea, Gabriela; Jolliet, Philippe; Brochard, Laurent

    2011-11-01

    To evaluate the efficacy of delivering a mixture of helium and oxygen gas (He–O2) in spontaneous ventilation. Three high oxygen flow reservoir masks were tested: the Heliox21, specifically designed for helium; the Hi-Ox80 mask, with an inspiratory and an expiratory valve; and a standard high-concentration face mask. This prospective randomized crossover study was performed in six healthy volunteers in a laboratory setting. Volunteers breathed a mixture of 78% He/22% O2 through each of the masks under two different breathing conditions (rest and hyperventilation: minute ventilation of 14.9 ± 6.1 and 26.7 ± 8.7 L min(−1), respectively) and four different He–O2 flow rates (7, 10, 12, and 15 L min(−1)). A nasopharyngeal catheter was used to estimate He pharyngeal concentration (Fp [He]) in the airways in order to determine the percentage of contamination with room air (% air cont) at end-expiration. Under all testing conditions, the Hi-Ox80 mask presented a significantly lower % air cont. During resting breathing pattern, a Fp [He] higher than 50% was achieved in 54% of the tests performed with the Hi-Ox80 mask compared to 29% for the Heliox21 mask and only 17% for the standard mask. At hyperventilation, a Fp [He] higher than 50% was achieved in 17% of the tests performed with the Hi-Ox mask compared to 4% for the other two masks. He–O2 administration via the usual high-concentration reservoir masks results in significant dilution by room air. The Hi-Ox80 mask minimized room air contamination and much more frequently achieved a pharyngeal He concentration higher than 50%.

  4. The effect of breathing an ambient low‐density, hyperoxic gas on the perceived effort of breathing and maximal performance of exercise in well‐trained athletes

    PubMed Central

    Ansley, L; Petersen, D; Thomas, A; Gibson, A St Clair; Robson‐Ansley, P; Noakes, T D

    2007-01-01

    Background The role of the perception of breathing effort in the regulation of performance of maximal exercise remains unclear. Aims To determine whether the perceived effort of ventilation is altered through substituting a less dense gas for normal ambient air and whether this substitution affects performance of maximal incremental exercise in trained athletes. Methods Eight highly trained cyclists (mean SD) maximal oxygen consumption (VO2max) = 69.9 (7.9) (mlO2/kg/min) performed two randomised maximal tests in a hyperbaric chamber breathing ambient air composed of either 35% O2/65% N2 (nitrox) or 35% O2/65% He (heliox). A ramp protocol was used in which power output was incremented at 0.5 W/s. The trials were separated by at least 48 h. The perceived effort of breathing was obtained via Borg Category Ratio Scales at 3‐min intervals and at fatigue. Oxygen consumption (VO2) and minute ventilation (VE) were monitored continuously. Results Breathing heliox did not change the sensation of dyspnoea: there were no differences between trials for the Borg scales at any time point. Exercise performance was not different between the nitrox and heliox trials (peak power output = 451 (58) and 453 (56) W), nor was VO2max (4.96 (0.61) and 4.88 (0.65) l/min) or maximal VE (157 (24) and 163 (22) l/min). Between‐trial variability in peak power output was less than either VO2max or maximal VE. Conclusion Breathing a less dense gas does not improve maximal performance of exercise or reduce the perception of breathing effort in highly trained athletes, although an attenuated submaximal tidal volume and VE with a concomitant reduction in VO2 suggests an improved gas exchange and reduced O2 cost of ventilation when breathing heliox. PMID:17062658

  5. Functional properties of a newly identified C-terminal splice variant of Cav1.3 L-type Ca2+ channels.

    PubMed

    Bock, Gabriella; Gebhart, Mathias; Scharinger, Anja; Jangsangthong, Wanchana; Busquet, Perrine; Poggiani, Chiara; Sartori, Simone; Mangoni, Matteo E; Sinnegger-Brauns, Martina J; Herzig, Stefan; Striessnig, Jörg; Koschak, Alexandra

    2011-12-09

    An intramolecular interaction between a distal (DCRD) and a proximal regulatory domain (PCRD) within the C terminus of long Ca(v)1.3 L-type Ca(2+) channels (Ca(v)1.3(L)) is a major determinant of their voltage- and Ca(2+)-dependent gating kinetics. Removal of these regulatory domains by alternative splicing generates Ca(v)1.3(42A) channels that activate at a more negative voltage range and exhibit more pronounced Ca(2+)-dependent inactivation. Here we describe the discovery of a novel short splice variant (Ca(v)1.3(43S)) that is expressed at high levels in the brain but not in the heart. It lacks the DCRD but, in contrast to Ca(v)1.3(42A), still contains PCRD. When expressed together with α2δ1 and β3 subunits in tsA-201 cells, Ca(v)1.3(43S) also activated at more negative voltages like Ca(v)1.3(42A) but Ca(2+)-dependent inactivation was less pronounced. Single channel recordings revealed much higher channel open probabilities for both short splice variants as compared with Ca(v)1.3(L). The presence of the proximal C terminus in Ca(v)1.3(43S) channels preserved their modulation by distal C terminus-containing Ca(v)1.3- and Ca(v)1.2-derived C-terminal peptides. Removal of the C-terminal modulation by alternative splicing also induced a faster decay of Ca(2+) influx during electrical activities mimicking trains of neuronal action potentials. Our findings extend the spectrum of functionally diverse Ca(v)1.3 L-type channels produced by tissue-specific alternative splicing. This diversity may help to fine tune Ca(2+) channel signaling and, in the case of short variants lacking a functional C-terminal modulation, prevent excessive Ca(2+) accumulation during burst firing in neurons. This may be especially important in neurons that are affected by Ca(2+)-induced neurodegenerative processes.

  6. Carbon-14 urea breath test: does it work in patients with partial gastric resection?

    PubMed

    Dede, Fuat; Civen, Hüseyin; Dane, Faysal; Aliustaoglu, Mehmet; Turhal, Serdar; Turoglu, Halil Turgut; Inanir, Sabahat

    2015-11-01

    The diagnostic value of Carbon-14 urea breath test (C-14 UBT) in the detection of Helicobacter pylori (H. pylori) infection in non-operated patients has been proved. However, the efficacy of C-14 UBT in patients with partial gastric resection (PGR) has not been evaluated yet. Herein, the results of the C-14 UBT and H. pylori stool antigen test (HpSAT) in this patient group were compared with the endoscopic findings. Multi-breath samples C-14 UBT and HpSAT were performed in all patients on the same day. Histology was used as a gold standard for testing C-14 UBT and HpSAT diagnostic efficacies. 30 patients (mean age: 54.6 ± 11 year) with PGR were included. The sensitivity and specificity of standard C-14 UBT were 29 and 100 %, respectively. When breath samples were collected at 20th min, and >35 CPM was selected as radioactivity threshold, the sensitivity raised to 86 % without any loss of specificity. The specificity and sensitivity of the HpSAT were 71 and 96 %, respectively. The sensitivity of the standard C-14 UBT was very poor for patients with PGR, and results of HpSAT were superior in this population. Certain modifications are needed if C-14 UBT is to be used in PGR patients.

  7. Optimization of PROPELLER reconstruction for free-breathing T1-weighted cardiac imaging.

    PubMed

    Huang, Teng-Yi; Tseng, Yu-Shen; Tang, Yu-Wei; Lin, Yi-Ru

    2012-08-01

    Clinical cardiac MR imaging techniques generally require patients to hold their breath during the scanning process to minimize respiratory motion-related artifacts. However, some patients cannot hold their breath because of illness or limited breath-hold capacity. This study aims to optimize the PROPELLER reconstruction for free-breathing myocardial T1-weighted imaging. Eight healthy volunteers (8 men; mean age 26.4 years) participated in this study after providing institutionally approved consent. The PROPELLER encoding method can reconstruct a low-resolution image from every blade because of k-space center oversampling. This study investigated the feasibility of extracting a respiratory trace from the PROPELLER blades by implementing a fully automatic region of interest selection and introducing a best template index to account for the property of the human respiration cycle. Results demonstrated that the proposed algorithm significantly improves the contrast-to-noise ratio and the image sharpness (p < 0.05). The PROPELLER method is expected to provide a robust tool for clinical application in free-breathing myocardial T1-weighted imaging. It could greatly facilitate the acquisition procedures during such a routine examination.

  8. Measurement of 13CO2 in expired air as an index of compliance to a high carbohydrate diet naturally enriched in 13C.

    PubMed

    Gay, L J; Schutz, Y; DiVetta, V; Schneiter, P; Tappy, L; Jéquier, E

    1994-09-01

    The aim of this study was to determine whether breath 13CO2 measurements could be used to assess the compliance to a diet containing carbohydrates naturally enriched in 13C. The study was divided into two periods: Period 1 (baseline of 4 days) with low 13C/12C ratio carbohydrates. Period 2 (5 days) isocaloric diet with a high 13C/12C ratio (corn, cane sugar, pineapple, millet) carbohydrates. Measurements were made of respiratory gas exchange by indirect calorimetry, urinary nitrogen excretion and breath 13CO2 every morning in post-absorptive conditions, both in resting state and during a 45-min low intensity exercise (walking on a treadmill). The subjects were 10 healthy lean women (BMI 20.4 +/- 1.7 kg/m2, % body fat 24.4 +/- 1.3%), the 13C enrichment of oxidized carbohydrate and breath 13CO2 were compared to the enrichment of exogenous dietary carbohydrates. At rest the enrichment of oxidized carbohydrate increased significantly after one day of 13C carbohydrate enriched diet and reached a steady value (103 +/- 16%) similar to the enrichment of exogenous carbohydrates. During exercise, the 13C enrichment of oxidized carbohydrate remained significantly lower (68 +/- 17%) than that of dietary carbohydrates. The compliance to a diet with a high content of carbohydrates naturally enriched in 13C may be assessed from the measurement of breath 13CO2 enrichment combined with respiratory gas exchange in resting, postabsorptive conditions.

  9. Further confirmation of the MED13L haploinsufficiency syndrome.

    PubMed

    van Haelst, Mieke M; Monroe, Glen R; Duran, Karen; van Binsbergen, Ellen; Breur, Johannes M; Giltay, Jacques C; van Haaften, Gijs

    2015-01-01

    MED13L haploinsufficiency syndrome has been described in two patients and is characterized by moderate intellectual disability (ID), conotruncal heart defects, facial abnormalities and hypotonia. Missense mutations in MED13L are linked to transposition of the great arteries and non-syndromal intellectual disability. Here we describe two novel patients with de novo MED13L aberrations. The first patient has a de novo mutation in the splice acceptor site of exon 5 of MED13L. cDNA analysis showed this mutation results in an in-frame deletion, removing 15 amino acids in middle of the conserved MED13L N-terminal domain. The second patient carries a de novo deletion of exons 6-20 of MED13L. Both patients show features of the MED13L haploinsufficiency syndrome, except for the heart defects, thus further confirming the existence of the MED13L haploinsufficiency syndrome.

  10. Unloading work of breathing during high-frequency oscillatory ventilation: a bench study

    PubMed Central

    van Heerde, Marc; Roubik, Karel; Kopelent, Vitek; Plötz, Frans B; Markhorst, Dick G

    2006-01-01

    Introduction With the 3100B high-frequency oscillatory ventilator (SensorMedics, Yorba Linda, CA, USA), patients' spontaneous breathing efforts result in a high level of imposed work of breathing (WOB). Therefore, spontaneous breathing often has to be suppressed during high-frequency oscillatory ventilation (HFOV). A demand-flow system was designed to reduce imposed WOB. Methods An external gas flow controller (demand-flow system) accommodates the ventilator fresh gas flow during spontaneous breathing simulation. A control algorithm detects breathing effort and regulates the demand-flow valve. The effectiveness of this system has been evaluated in a bench test. The Campbell diagram and pressure time product (PTP) are used to quantify the imposed workload. Results Using the demand-flow system, imposed WOB is considerably reduced. The demand-flow system reduces inspiratory imposed WOB by 30% to 56% and inspiratory imposed PTP by 38% to 59% compared to continuous fresh gas flow. Expiratory imposed WOB was decreased as well by 12% to 49%. In simulations of shallow to normal breathing for an adult, imposed WOB is 0.5 J l-1 at maximum. Fluctuations in mean airway pressure on account of spontaneous breathing are markedly reduced. Conclusion The use of the demand-flow system during HFOV results in a reduction of both imposed WOB and fluctuation in mean airway pressure. The level of imposed WOB was reduced to the physiological range of WOB. Potentially, this makes maintenance of spontaneous breathing during HFOV possible and easier in a clinical setting. Early initiation of HFOV seems more possible with this system and the possibility of weaning of patients directly on a high-frequency oscillatory ventilator is not excluded either. PMID:16848915

  11. Breath-hold time during cold water immersion: effects of habituation with psychological training.

    PubMed

    Barwood, Martin J; Datta, Avijit K; Thelwell, Richard C; Tipton, Michael J

    2007-11-01

    The loss of the conscious control of respiration on whole body cold water immersion (CWI) can result in the aspiration of water and drowning. Repeated CWI reduces the respiratory drive evoked by CWI and should prolong breath-hold time on CWI (BHmax(CWI)). Psychological skills training (PST) can also increase BHmax(CWI) by improving the ability of individuals to consciously suppress the drive to breathe. This study tested the hypothesis that combining PST and repeated CWI would extend BHmax(CWI) beyond that seen following only repeated CWI. There were 20 male subjects who completed two 2.5-min, head-out breath-hold CWI (BH1 and BH2) in water at 12 degrees C. Following BH1, subjects were matched on BHmax(CWI) and allocated to a habituation (HAB) group or a habituation plus PST group (H+PST). Between BH1 and BH2 both experimental groups undertook five 2.5-min CWI on separate days, during which they breathed freely. The H+PST also received psychological training to help tolerate cold and suppress the drive to breathe on immersion to extend BHmax(CWI). During BH1, mean BHmax(CWI) (+/- SD) in the HAB group was 22.00 (10.33) s and 22.38 (10.65) s in the H+PST. After the five free-breathing CWI, both groups had a longer BHmax(CWI) in BH2. The HAB group improved by 14.13 (20.21) s, an increase of 73%. H+PST improved by 26.86 (24.70) s, a 120% increase. No significant differences were identified between the groups. Habituation significantly increases BHmax on CWI, the addition of PST did not result in statistically significant improvements in BHmax(CWI), but may have practical significance.

  12. Inward contaminant leakage tests of the S-Tron Corporation emergency escape breathing device.

    DOT National Transportation Integrated Search

    1992-04-01

    At the request of S-Tron Corporation, to support their contract with the U.S. Navy, performance tests of the Emergency Escape Breathing Device (EEBD) were conducted in the Environmental Physiology Research Section contaminant leakage chamber. Sulfur ...

  13. Work of breathing during lung-protective ventilation in patients with acute lung injury and acute respiratory distress syndrome: a comparison between volume and pressure-regulated breathing modes.

    PubMed

    Kallet, Richard H; Campbell, Andre R; Dicker, Rochelle A; Katz, Jeffrey A; Mackersie, Robert C

    2005-12-01

    Pressure-control ventilation (PCV) and pressure-regulated volume-control (PRVC) ventilation are used during lung-protective ventilation because the high, variable, peak inspiratory flow rate (V (I)) may reduce patient work of breathing (WOB) more than the fixed V (I) of volume-control ventilation (VCV). Patient-triggered breaths during PCV and PRVC may result in excessive tidal volume (V(T)) delivery unless the inspiratory pressure is reduced, which in turn may decrease the peak V (I). We tested whether PCV and PRVC reduce WOB better than VCV with a high, fixed peak V (I) (75 L/min) while also maintaining a low V(T) target. Fourteen nonconsecutive patients with acute lung injury or acute respiratory distress syndrome were studied prospectively, using a random presentation of ventilator modes in a crossover, repeated-measures design. A target V(T) of 6.4 + 0.5 mL/kg was set during VCV and PRVC. During PCV the inspiratory pressure was set to achieve the same V(T). WOB and other variables were measured with a pulmonary mechanics monitor (Bicore CP-100). There was a nonsignificant trend toward higher WOB (in J/L) during PCV (1.27 + 0.58 J/L) and PRVC (1.35 + 0.60 J/L), compared to VCV (1.09 + 0.59 J/L). While mean V(T) was not statistically different between modes, in 40% of patients, V(T) markedly exceeded the lung-protective ventilation target during PRVC and PCV. During lung-protective ventilation, PCV and PRVC offer no advantage in reducing WOB, compared to VCV with a high flow rate, and in some patients did not allow control of V(T) to be as precise.

  14. Let's party tonight: drinking patterns and breath alcohol values at high school parties.

    PubMed

    Schwartz, R H; Little, D L

    1997-05-01

    This study sought to determine whether the number of alcohol-containing beverages consumed by adolescents attending a "typical" high school weekend party was planned or spontaneous. A second objective was to understand the role of the designated driver and whether he or she honored a pledge of sobriety. A printed, anonymous survey with signed informed consent was distributed to 52 high school students from three different suburban high schools during three weekend high school parties. In addition, subjects underwent breath alcohol testing using the Intoximeter breath alcohol instrument. Salivary alcohol measurements were also obtained using Alco-Screen. Levels were measured in volunteers on entry and exit from the party. Fifty-two students volunteered to participate in the survey. Eleven participants volunteered to be designated drivers, nine of whom did not drink alcohol at this party. By the end of each party, the 26 boys had consumed a mean of 10 drinks, and the 16 girls had consumed 4.1 drinks, almost exactly what they had predicted at the time of arrival. By departure time, 22 (54%) of the drinkers had a breath alcohol value of .10 g/dL or greater, while only three (7%), had alcohol values of .02 g/dL or less. Blackouts were common and had been experienced by 73% of all the students surveyed. Twenty-seven percent of those surveyed had been involved in some form of physical violence while drinking. Eleven percent of the female participants reported being sexually assaulted while they or their attacker were drunk. Most of the 42 drinkers believed that it was acceptable for designated drivers to drink at least two beers. Two intoxicated designated drivers were driven home by sober friends. High school students in this study knew before attending a party the quantity of beer they would consume. Survey participants believed that it is acceptable practice for designated drivers to drink alcohol at parties; 13% of those who intended to drive after these parties were

  15. Single-breath analysis using a novel simple sampler and capillary electrophoresis with contactless conductometric detection.

    PubMed

    Greguš, Michal; Foret, František; Kubáň, Petr

    2015-02-01

    The analysis of ionic content of exhaled breath condensate (EBC) from one single breath by CE with C(4) D is demonstrated for the first time. A miniature sampler made from a 2-mL syringe and an aluminum cooling cylinder for collection of EBC was developed. Various parameters of the sampler that influence its collection efficiency, repeatability, and effect of respiratory patterns were studied in detail. Efficient procedures for the cleanup of the miniature sampler were also developed and resulted in significant improvement of sampling repeatability. Analysis of EBC was performed by CE-C(4) D in a 60 mM MES/l-histidine BGE with 30 μM CTAB and 2 mM 18-crown-6 at pH 6 and excellent repeatability of migration times (RSD < 1.3% (n = 7)) and peak areas (RSD < 7% (n = 7)) of 12 inorganic anions, cations, and organic acids was obtained. It has been shown that the breathing pattern has a significant impact on the concentration of the analytes in the collected EBC. As the ventilatory pattern can be easily controlled during single exhalation, the developed collection system and method provides a highly reproducible and fast way of collecting EBC with applicability in point-of-care diagnostics. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. 46 CFR 160.176-13 - Approval Tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Approval Tests. 160.176-13 Section 160.176-13 Shipping...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Inflatable Lifejackets § 160.176-13 Approval Tests. (a) General. (1) This section contains requirements for approval tests and examinations of inflatable lifejackets...

  17. Bioconversion of glycerol to 1,3-propanediol in thin stillage-based media by engineered Lactobacillus panis PM1.

    PubMed

    Kang, Tae Sun; Korber, Darren R; Tanaka, Takuji

    2014-04-01

    Thin stillage (TS) is a waste residue that remains after bioethanol production, and its disposal reflects the high costs of bioethanol production. Thus, the development of cost-effective ways to process TS is a pending issue in bioethanol plants. The aim of this study was to evaluate the utilization of TS for the production of the valuable chemical, 1,3-propanediol (1,3-PDO), by Lactobacillus panis PM1. Different fermentation parameters, including temperature, pH and strains [wild-type and a recombinant strain expressing a NADPH-dependent aldehyde reductase (YqhD) gene] were tested in batch and fed-batch cultivations. The highest 1,3-PDO concentration (12.85 g/L) and yield (0.84 g/g) were achieved by batch fermentation at pH-4.5/30 °C by the YqhD recombinant strain. Furthermore, pH-controlled batch fermentation reduced the total fermentation period, resulting in the maximal 1,3-PDO concentration of 16.23 g/L and yield of 0.72 g/g in TS without an expensive nutrient or nitrogen (e.g., yeast extract, beef extract, and peptone) supplementation. The addition of two trace elements, Mg(2+) and Mn(2+), in TS increased 1,3-PDO yield (0.74 g/g) without 3-hydroxypropionaldehyde production, the only intermediate of 1,3-PDO biosynthetic pathway in L. panis PM1. Our results suggest that L. panis PM1 can offer a cost-effective process that utilizes the TS to produce a value-added chemical, 1,3-PDO.

  18. Structural characterization and comparative modeling of PD-Ls 1-3, type 1 ribosome-inactivating proteins from summer leaves of Phytolacca dioica L.

    PubMed

    Di Maro, Antimo; Chambery, Angela; Carafa, Vincenzo; Costantini, Susan; Colonna, Giovanni; Parente, Augusto

    2009-03-01

    The amino acid sequence and glycan structure of PD-L1, PD-L2 and PD-L3, type 1 ribosome-inactivating proteins isolated from Phytolacca dioica L. leaves, were determined using a combined approach based on peptide mapping, Edman degradation and ESI-Q-TOF MS in precursor ion discovery mode. The comparative analysis of the 261 amino acid residue sequences showed that PD-L1 and PD-L2 have identical primary structure, as it is the case of PD-L3 and PD-L4. Furthermore, the primary structure of PD-Ls 1-2 and PD-Ls 3-4 have 81.6% identity (85.1% similarity). The ESI-Q-TOF MS analysis confirmed that PD-Ls 1-3 were glycosylated at different sites. In particular, PD-L1 contained three glycidic chains with the well known paucidomannosidic structure (Man)(3) (GlcNAc)(2) (Fuc)(1) (Xyl)(1) linked to Asn10, Asn43 and Asn255. PD-L2 was glycosylated at Asn10 and Asn43, and PD-L3 was glycosylated only at Asn10. PD-L4 was confirmed to be not glycosylated. Despite an overall high structural similarity, the comparative modeling of PD-L1, PD-L2, PD-L3 and PD-L4 has shown potential influences of the glycidic chains on their adenine polynucleotide glycosylase activity on different substrates.

  19. 46 CFR 13.115 - Chemical testing requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 1 2014-10-01 2014-10-01 false Chemical testing requirements. 13.115 Section 13.115... TANKERMEN General § 13.115 Chemical testing requirements. Each applicant for an original tankerman endorsement must provide evidence of having passed a chemical test for dangerous drugs or of qualifying for an...

  20. Deep-breathing exercises reduce atelectasis and improve pulmonary function after coronary artery bypass surgery.

    PubMed

    Westerdahl, Elisabeth; Lindmark, Birgitta; Eriksson, Tomas; Friberg, Orjan; Hedenstierna, Göran; Tenling, Arne

    2005-11-01

    To investigate the effects of deep-breathing exercises on pulmonary function, atelectasis, and arterial blood gas levels after coronary artery bypass graft (CABG) surgery. In a prospective, randomized trial, patients performing deep-breathing exercises (n = 48) were compared to a control group (n = 42) who performed no breathing exercises postoperatively. Patient management was similar in the groups in terms of assessment, positioning, and mobility. The patients in the deep-breathing group were instructed to perform breathing exercises hourly during daytime for the first 4 postoperative days. The exercises consisted of 30 slow, deep breaths performed with a positive expiratory pressure blow-bottle device (+ 10 cm H(2)O). Spirometric measurements, spiral CT (three transverse levels), arterial blood gas analysis, and scoring of subjective experience of the breathing exercises were performed on the fourth postoperative day. Atelectasis was only half the size in the deep-breathing group compared to the control group, amounting to 2.6 +/- 2.2% vs 4.7 +/- 5.7% (p = 0.045) at the basal level and 0.1 +/- 0.2% vs 0.3 +/- 0.5% (mean +/- SD) [p = 0.01] at the apical level. Compared to the control subjects, the patients in the deep-breathing group had a significantly smaller reduction in FVC (to 71 +/- 12%, vs 64 +/- 13% of the preoperative values; p = 0.01) and FEV(1) (to 71 +/- 11%, vs 65 +/- 13% of the preoperative values; p = 0.01). Arterial oxygen tension, carbon dioxide tension, fever, or length of ICU or hospital stay did not differ between the groups. In the deep-breathing group, 72% of the patients experienced a subjective benefit from the exercises. Patients performing deep-breathing exercises after CABG surgery had significantly smaller atelectatic areas and better pulmonary function on the fourth postoperative day compared to a control group performing no exercises.

  1. Does rhinoplasty improve nasal breathing?

    PubMed

    Xavier, Rui

    2010-08-01

    Rhinoplasty is a surgical procedure that aims to improve nasal aesthetics and nasal breathing. The aesthetic improvement of the nose is usually judged subjectively by the patient and the surgeon, but the degree of improvement of nasal obstruction is difficult to assess by clinical examination only. The measurement of peak nasal inspiratory flow (PNIF) is a reliable tool that has been shown to correlate with other objective methods of assessing nasal breathing and with patients' symptoms of nasal obstruction. Twenty-three consecutive patients undergoing rhinoplasty have been evaluated by measurement of PNIF before and after surgery. All but three patients had an increase in PNIF after surgery. The mean preoperative PNIF was 86.5 L/min and the mean postoperative PNIF was 123.0 L/min ( P < 0.001). Not surprisingly, the greatest improvement in PNIF was achieved when bilateral spreader grafts were used. This study suggests that rhinoplasty does improve nasal breathing. (c) Thieme Medical Publishers

  2. A comparison between lactose breath test and quick test on duodenal biopsies for diagnosing lactase deficiency in patients with self-reported lactose intolerance.

    PubMed

    Furnari, Manuele; Bonfanti, Daria; Parodi, Andrea; Franzè, Jolanda; Savarino, Edoardo; Bruzzone, Luca; Moscatelli, Alessandro; Di Mario, Francesco; Dulbecco, Pietro; Savarino, Vincenzo

    2013-02-01

    A lactose breath test (LBT) is usually used to diagnose lactase deficiency, and a lactose quick test (LQT) has been proposed as a new test on duodenal biopsies to detect this disorder. We aimed to assess the diagnostic accuracy of LBT and LQT and their ability to predict the clinical response to a lactose-free diet in patients with self-reported lactose intolerance. Fifty-five patients (age 47 ± 14 y; M/F 15/36) underwent upper gastrointestinal endoscopy and 25g-LBT. Two duodenal biopsies were taken to determine lactase deficiency (normal, mild, or severe) by LQT and to rule out other causes of secondary lactose malabsorption. Patients with a positive LBT and normal LQT also underwent a glucose breath test to exclude small intestinal bacterial overgrowth as a cause of the former result. The severity of gastrointestinal symptoms was measured with a GSS questionnaire, under basal condition and 1 month after a lactose-free diet. Lactose malabsorption was detected in 31/51 patients with LBT and in 37/51 patients with LQT (P = NS). Celiac disease was found in 2 patients. Two LBT+ patients showed a positive glucose breath test for small intestinal bacterial overgrowth. Eight patients had a mild hypolactasia by LQT and a negative LBT, but they had a significant improvement of symptoms after diet. LQT and LBT were concordant in 83% of cases and predicted the response to a lactose-free diet in 98% and 81% of the cases, respectively (P = 0.03). LQT is as sensitive as LBT in detecting lactase deficiency; however, it seems to be more accurate than LBT in predicting the clinical response to a lactose-free diet.

  3. Noninvasive measurement of plasma glucose from exhaled breath in healthy and type 1 diabetic subjects

    PubMed Central

    Oliver, Stacy R.; Ngo, Jerry; Flores, Rebecca; Midyett, Jason; Meinardi, Simone; Carlson, Matthew K.; Rowland, F. Sherwood; Blake, Donald R.; Galassetti, Pietro R.

    2011-01-01

    Effective management of diabetes mellitus, affecting tens of millions of patients, requires frequent assessment of plasma glucose. Patient compliance for sufficient testing is often reduced by the unpleasantness of current methodologies, which require blood samples and often cause pain and skin callusing. We propose that the analysis of volatile organic compounds (VOCs) in exhaled breath can be used as a novel, alternative, noninvasive means to monitor glycemia in these patients. Seventeen healthy (9 females and 8 males, 28.0 ± 1.0 yr) and eight type 1 diabetic (T1DM) volunteers (5 females and 3 males, 25.8 ± 1.7 yr) were enrolled in a 240-min triphasic intravenous dextrose infusion protocol (baseline, hyperglycemia, euglycemia-hyperinsulinemia). In T1DM patients, insulin was also administered (using differing protocols on 2 repeated visits to separate the effects of insulinemia on breath composition). Exhaled breath and room air samples were collected at 12 time points, and concentrations of ∼100 VOCs were determined by gas chromatography and matched with direct plasma glucose measurements. Standard least squares regression was used on several subsets of exhaled gases to generate multilinear models to predict plasma glucose for each subject. Plasma glucose estimates based on two groups of four gases each (cluster A: acetone, methyl nitrate, ethanol, and ethyl benzene; cluster B: 2-pentyl nitrate, propane, methanol, and acetone) displayed very strong correlations with glucose concentrations (0.883 and 0.869 for clusters A and B, respectively) across nearly 300 measurements. Our study demonstrates the feasibility to accurately predict glycemia through exhaled breath analysis over a broad range of clinically relevant concentrations in both healthy and T1DM subjects. PMID:21467303

  4. Structural and thermal stabilities of layered Li(Ni 1/3Co 1/3Mn 1/3)O 2 materials in 18650 high power batteries

    NASA Astrophysics Data System (ADS)

    He, Yan-Bing; Ning, Feng; Yang, Quan-Hong; Song, Quan-Sheng; Li, Baohua; Su, Fangyuan; Du, Hongda; Tang, Zhi-Yuan; Kang, Feiyu

    The structural and thermal stabilities of the layered Li(Ni 1/3Co 1/3Mn 1/3)O 2 cathode materials under high rate cycling and abusive conditions are investigated using the commercial 18650 Li(Ni 1/3Co 1/3Mn 1/3)O 2/graphite high power batteries. The Li(Ni 1/3Co 1/3Mn 1/3)O 2 materials maintain their layered structure even when the power batteries are subjected to 200 cycles with 10 C discharge rate at temperatures of 25 and 50 °C, whereas their microstructure undergoes obvious distortion, which leads to the relatively poor cycling performance of power batteries at high charge/discharge rates and working temperature. Under abusive conditions, the increase in the battery temperature during overcharge is attributed to both the reactions of electrolyte solvents with overcharged graphite anode and Li(Ni 1/3Co 1/3Mn 1/3)O 2 cathode and the Joule heat that results from the great increase in the total resistance (R cell) of batteries. The reactions of fully charged Li(Ni 1/3Co 1/3Mn 1/3)O 2 cathodes and graphite anodes with electrolyte cannot be activated during short current test in the fully charged batteries. However, these reactions occur at around 140 °C in the fully charged batteries during oven test, which is much lower than the temperature of about 240 °C required for the reactions outside batteries.

  5. Fasting Glycemia in Sleep Disordered Breathing: Lowering the Threshold on Oxyhemoglobin Desaturation

    PubMed Central

    Stamatakis, Katherine; Sanders, Mark H.; Caffo, Brian; Resnick, Helaine E.; Gottlieb, Dan J.; Mehra, Reena; Punjabi, Naresh M.

    2008-01-01

    Study Objectives: Commonly used definitions of sleep-disordered breathing (SDB) are based on identifying discrete events of breathing abnormalities during sleep that are accompanied by an oxyhemoglobin desaturation (ΔSaO2) of at least 4%. However, it is not known whether disordered breathing events with oxyhemoglobin desaturation less than 4% are associated with clinical sequelae such as abnormalities in fasting glycemia. Design: Cross-sectional study. Subjects and Setting: Participants from the Sleep Heart Health Study (SHHS) with a fasting glucose measurement made within a year of the baseline polysomnogram. Measurements and Results: SDB severity was defined using the apnea-hypopnea index (AHI) and the hypopnea index (HI) by counting events with different levels of oxyhemoglobin desaturation (0.0%–1.9%, 2.0%–2.9%, 3.0%–3.9%, >4.0%). Fasting glucose levels were used to classify individuals into normal (<100 mg/dL), impaired (100–125 mg/dL), and diabetic (>126 mg/dL) groups. Ordinal logistic regression was used to determine the adjusted relative odds of an abnormal glucose value across quartiles of the hypopnea index, independent of factors such as age, body mass index, waist circumference, and usual sleep duration. The prevalence of impaired and diabetic fasting glucose in the analytical sample was 32.9% and 5.8%, respectively. The covariate-adjusted relative odds of impaired or diabetic fasting glucose in the highest versus the lowest AHI quartile was 1.35 (95% CI: 1.04–1.76) for events with a ΔSaO2 ≥ 4.0%, 1.72 (95% CI: 1.20–2.48) for events with a ΔSaO2 between 3.0%-3.9%, 1.41 (95% CI: 1.07–1.86) for events with a ΔSaO2 between 2.0%–2.9%, and 1.07 (95% CI: 0.84–1.37) for events with a ΔSaO2 between 0.0%–1.9%. The corresponding odds ratios for the HI were 1.47 (95% CI: 1.131.92), 2.25 (95% CI: 1.59–3.19), 1.44 (95% CI: 1.09–1.90), and 1.15 (95% CI: 0.90–1.47), respectively. Conclusions: The results of this study indicate that

  6. Increased Protein Requirements in Female Athletes after Variable-Intensity Exercise.

    PubMed

    Wooding, Denise J; Packer, Jeff E; Kato, Hiroyuki; West, Daniel W D; Courtney-Martin, Glenda; Pencharz, Paul B; Moore, Daniel R

    2017-11-01

    Protein requirements are primarily studied in the context of resistance or endurance exercise with little research devoted to variable-intensity intermittent exercise characteristic of many team sports. Further, female populations are underrepresented in dietary sports science studies. We aimed to determine a dietary protein requirement in active females performing variable-intensity intermittent exercise using the indicator amino acid oxidation (IAAO) method. We hypothesized that these requirements would be greater than current IAAO-derived estimates in nonactive adult males. Six females (21.2 ± 0.8 yr, 68.8 ± 4.1 kg, 47.1 ± 1.2 mL O2·kg·min; mean ± SE) completed five to seven metabolic trials during the luteal phase of the menstrual cycle. Participants performed a modified Loughborough Intermittent Shuttle Test before consuming eight hourly mixed meals providing the test protein intake (0.2-2.66 g·kg·d), 6 g·kg·d CHO and sufficient energy for resting and exercise-induced energy expenditure. Protein was provided as crystalline amino acid modeling egg protein with [C]phenylalanine as the indicator amino acid. Phenylalanine turnover (Q) was determined from urinary [C]phenylalanine enrichment. Breath CO2 excretion (FCO2) was analyzed using mixed effects biphase linear regression with the breakpoint and upper 95% confidence interval approximating the estimated average requirement and recommended dietary allowance, respectively. Protein intake had no effect on Q (68.7 ± 7.3 μmol·kg·h; mean ± SE). FCO2 displayed a robust biphase response (R = 0.66) with an estimated average requirement of 1.41 g·kg·d and recommended dietary allowance of 1.71 g·kg·d. The protein requirement estimate of 1.41 and 1.71 g·kg·d for females performing variable-intensity intermittent exercise is greater than the IAAO-derived estimates of adult males (0.93 and 1.2 g·kg·d) and at the upper range of the American College of Sports Medicine athlete recommendations (1.2-2.0 g·kg·d).

  7. The effect of radioactive iodine treatment on 14C urea breath test results in patients with hyperthyroidism.

    PubMed

    Arduc, Ayse; Dogan, Bercem Aycicek; Ozuguz, Ufuk; Tuna, Mazhar Muslim; Gokay, Ferhat; Tutuncu, Yasemin Ates; Isik, Serhat; Aydin, Yusuf; Peksoy, Irfan; Berker, Dilek; Guler, Serdar

    2014-12-01

    Radioactive Iodine therapy (RAIT) plays a major role in the treatment of hyperthyroidism. In addition to the thyroid gland, significant amounts of radioactive iodine are maintained in the stomach. The aim of this study was to determine if RAIT has any effect on Helicobacter pylori infection, based on the C urea breath test (UBT). The study included 85 patients with hyperthyroidism scheduled to undergo RAIT and 69 hyperthyroid subjects in whom methimazole treatment was planned. All subjects had pretreatment-positive UBT results, and the test was repeated on the first and third months after RAIT and methimazole treatment. After a mean RAIT dose of 15 mCi (range, 10-20 mCi), UBT became negative in 13 (15.3%) of 85 patients on the first month and 18 (21.2%) of 85 patients on the third month. All subjects treated with methimazole remained UBT positive on the first and third months of methimazole treatment (100%). Reduction in the number of UBT-positive patients on both the first and the third months after RAIT was statistically significant (P < 0.001). Distribution of hyperthyroidism etiologies and thyroid autoantibody levels in subjects with UBT that became negative and in subjects with UBT that remained positive were similar in the RAIT group (P > 0.05). Urea breath test negativity rates did not differ according to the radioiodine dose. Our findings indirectly showed that RAIT might have an antimicrobial effect on H. pylori. Clinical applications of this beneficial effect of RAIT on H. pylori should be further evaluated.

  8. Upper airway sleep-disordered breathing in women.

    PubMed

    Guilleminault, C; Stoohs, R; Kim, Y D; Chervin, R; Black, J; Clerk, A

    1995-04-01

    To investigate the various clinical presentations of sleep-disordered breathing in women. A retrospective case-control study. A sleep disorders clinic. 334 women, aged 18 years and older, seen between 1988 and 1993, who were diagnosed with upper airway sleep-disordered breathing. Controls were 60 women with insomnia and 100 men with sleep-disordered breathing. Clinical, anatomic, and polygraphic information. The mean lag time (+/- SD) in women between the appearance of symptoms and a positive diagnosis was 9.7 +/- 3.1 years; among participants 30 to 60 years of age, the duration of untreated symptoms differed (P < 0.001) between women and men. Sleep-disordered breathing was blamed for divorce or social isolation by 40% of the case patients. Abnormal maxillomandibular features were noted in 45% of the women with disordered breathing. Dysmenorrhea and amenorrhea (which disappeared after treatment with nasal continuous positive airway pressure) were reported in 43% of premenopausal women compared with 13% of persons in the control group of women with insomnia. Thirty-eight women (11.4%) with upper airway sleep-disordered breathing had a respiratory disturbance index of less than 5 and were significantly younger, had a smaller neck circumference, and had a lower body mass index than women with a respiratory disturbance index of 5 or more. Physicians should revise their understanding of upper airway sleep-disordered breathing so that they notice women with certain craniofacial features, a low body mass index, a small neck circumference, and a respiratory disturbance index of less than 5. These revisions may enable more rapid diagnosis and treatment of women with sleep-disordered breathing.

  9. NASOPHARYNGEAL CONCENTRATIONS IN THE HUMAN VOLUNTEER BREATHING ACETONE

    EPA Science Inventory

    In an effort to examine the absorption of a common chemical into the nasopharyngeal region in humans, a 57 year old male volunteer inhaled uniformly labeled 13C-acetone at 1.4 ppm for 30 min while performing different breathing maneuvers; nose inhale, nose exhale (NINE); mouth ...

  10. Limits of clinical tests to screen autonomic function in diabetes type 1.

    PubMed

    Ducher, M; Bertram, D; Sagnol, I; Cerutti, C; Thivolet, C; Fauvel, J P

    2001-11-01

    A precocious detection of cardiac autonomic dysfunction is of major clinical interest that could lead to a more intensive supervision of diabetic patients. However, classical clinical exploration of cardiac autonomic function is not easy to undertake in a reproducible way. Thus, respective interests of autonomic nervous parameters provided by both clinical tests and computerized analysis of resting blood pressure were checked in type 1 diabetic patients without orthostatic hypotension and microalbuminuria. Thirteen diabetic subjects matched for age and gender to thirteen healthy subjects volunteered to participate to the study. From clinical tests (standing up, deep breathing, Valsalva maneuver, handgrip test), autonomic function was scored according to Ewing's methodology. Analysis of resting beat to beat blood pressure provided autonomic indices of the cardiac function (spectral analysis or Z analysis). 5 of the 13 diabetic patients exhibited a pathological score (more than one pathological response) suggesting the presence of cardiovascular autonomic dysfunction. The most discriminative test was the deep breathing test. However, spectral indices of BP recordings and baro-reflex sensitivity (BRS) of these 5 subjects were similar to those of healthy subjects and of remaining diabetic subjects. Alteration in Ewing's score given by clinical tests may not reflect an alteration of cardiac autonomic function in asymptomatic type 1 diabetic patients, because spectral indices of sympathetic and parasympathetic (including BRS) function were within normal range. Our results strongly suggest to confront results provided by both methodologies before concluding to an autonomic cardiac impairment in asymptomatic diabetic patients.

  11. Measurement of breath ammonia for detection of patients with chronic kidney disease.

    PubMed

    Bevc, Sebastjan; Mohorko, Eva; Kolar, Mitja; Brglez, Polona; Holobar, Andrej; Kniepeiss, Daniela; Podbregar, Matej; Piko, Nejc; Hojs, Nina; Knehtl, Maša; Ekart, Robert; Hojs, Radovan

    In a healthy individual, ammonia is converted to urea in the liver. Urea is then transported through the bloodstream and then excreted into the urine by the kidneys. In patients with chronic kidney disease (CKD), the accumulated urea is degraded by salivary urease into ammonia, which is then excreted by breathing. Breath ammonia can therefore be used for detecting the increased nitrogen-bearing wastes. In our pilot study, an electrochemical sensor was used to measure and analyze breath ammonia in healthy volunteers and patients with CKD. In our study, 8 patients with CKD (stages 4 and 5) and 6 healthy volunteers were enrolled. All participants were nonsmokers and without pulmonary or liver disease. One controlled breath sample was collected from each participant. Immediately after the sample was collected, a gas analyzer was used for measuring breath ammonia in our participants. Mean creatinine value of CKD patients was 455.2 ± 294.1 µmol/L and 62.1 ± 7.5 µmol/L for healthy volunteers. Breath ammonia levels (3.32 ± 2.19 ppm vs. 0.49 ± 0.08 ppm; p = 0.003) and measured electric current (4.33 ± 0.25 mA vs. 4.01 ± 0.01 mA; p = 0.003) were significantly higher in the CKD group. The results of our pilot study show that breath monitoring of ammonia can be a simple, useful, fast, and noninvasive tool for detection of advanced kidney impairment.
.

  12. Influence of acute and chronic treadmill exercise on rat plasma lactate and brain NPY, L-ENK, DYN A1-13.

    PubMed

    Chen, Jia-Xu; Zhao, Xin; Yue, Guang-Xin; Wang, Zhu-Feng

    2007-02-01

    This study was designed to investigate the effect of acute and chronic high-intensity treadmill exercise on changes in plasma lactate and brain neuropeptide (NPY), leucine-enkephalin (L-ENK), and dynorphin A(1-13) (DYN A(1-13)). Avidin-biotin complex (ABC) immunohistochemistry and image pattern analysis were used to observe the effect of chronic (total 7 weeks) and acute treadmill exercise (an initial speed of 15 m min(-1) gradually increased to 35 m min(-1) with 0 degrees, 20-25 min per day duration) on the changes of NPY, L-ENK, and DYN A(1-13) in different areas of rat brain. Plasma lactate was also measured in response to such exercise. Compared with preexercise control (P < 0.01), plasma lactate concentration significantly increased in the immediate postexercise; but it returned to the normal level soon after the 30 min postexercise. The content of NPY in paraventricular (PVN), dorsomedial (DMN), and ventromedial (VMN) hypothalamic nuclei continued to increase in 0, 30, and 180 min postexercise compared with preexercise control (P < 0.01). The content of L-ENK in caudate-putamen (CPu) significantly increased in the immediate postexercise compared with preexercise control (P < 0.01), but it gradually returned to the normal level after the 180 min postexercise. However, the content of DYN A(1-13) in PVN rose substantially only in 30 min postexercise in comparison with the preexercise control (P < 0.01). Thus, different changes of NPY, L-ENK, and DYN A(1-13) in response to such high-intensity exercise depend on the brain region and the time examined, especially, the contents of NPY in different brain regions continuously remain at a high level after such high-intensity exercise. And this high level might reduce energy expenditure and thus contribute to the stimulation of brain NPY neurons.

  13. Effect of exhaled moisture on breathing resistance of N95 filtering facepiece respirators.

    PubMed

    Roberge, Raymond J; Bayer, Emily; Powell, Jeffrey B; Coca, Aitor; Roberge, Marc R; Benson, Stacey M

    2010-08-01

    This study evaluated the effect of exhaled moisture on the breathing resistance of three classes of filtering facepiece respirators (FFR) following 4 h of continuous wear at a breathing volume of 40 l min(-1), utilizing an automated breathing and metabolic simulator as a human surrogate. After 4 h, inhalation and exhalation resistance increased by 0.43 and 0.23 mm of H(2)O pressure, respectively, and average moisture retention in the respirators was 0.26 ml. Under ambient conditions similar to those of the current study, and at similar breathing volumes, it is unlikely that exhaled moisture will add significantly to the breathing resistance of filtering facepiece respirators (FFR) over 4 h of use.

  14. ICL-based TDLAS sensor for real-time breath gas analysis of carbon monoxide isotopes.

    PubMed

    Ghorbani, Ramin; Schmidt, Florian M

    2017-05-29

    We present a compact sensor for carbon monoxide (CO) in air and exhaled breath based on a room temperature interband cascade laser (ICL) operating at 4.69 µm, a low-volume circular multipass cell and wavelength modulation absorption spectroscopy. A fringe-limited (1σ) sensitivity of 6.5 × 10 -8 cm -1 Hz -1/2 and a detection limit of 9 ± 5 ppbv at 0.07 s acquisition time are achieved, which constitutes a 25-fold improvement compared to direct absorption spectroscopy. Integration over 10 s increases the precision to 0.6 ppbv. The setup also allows measuring the stable isotope 13 CO in breath. We demonstrate quantification of indoor air CO and real-time detection of CO expirograms from healthy non-smokers and a healthy smoker before and after smoking. Isotope ratio analysis indicates depletion of 13 CO in breath compared to natural abundance.

  15. Comparison of ethanol concentrations in venous blood and end-expired breath during a controlled drinking study.

    PubMed

    Jones, A W; Andersson, L

    2003-03-12

    Concentration-time profiles of ethanol were determined for venous whole blood and end-expired breath during a controlled drinking experiment in which healthy men (n=9) and women (n=9) drank 0.40-0.65 g ethanol per kg body weight in 20-30 min. Specimens of blood and breath were obtained for analysis of ethanol starting at 50-60 min post-dosing and then every 30-60 min for 3-6 h. This protocol furnished 130 blood-breath pairs for statistical evaluation. Blood-ethanol concentration (BAC, mg/g) was determined by headspace gas chromatography and breath-ethanol concentration (BrAC, mg/2l) was determined with a quantitative infrared analyzer (Intoxilyzer 5000S), which is the instrument currently used in Sweden for legal purposes. In 18 instances the Intoxilyzer 5000S gave readings of 0.00 mg/2l whereas the actual BAC was 0.08 mg/g on average (range 0.04-0.15 mg/g). The remaining 112 blood- and breath-alcohol measurements were highly correlated (r=0.97) and the regression relationship was BAC=0.10+0.91BrAC and the residual standard deviation (S.D.) was 0.042 mg/g (8.4%). The slope (0.91+/-0.0217) differed significantly from unity being 9% low and the intercept (0.10+/-0.0101) deviated from zero (t=10.2, P<0.001), indicating the presence of both proportional and constant bias, respectively. The mean bias (BAC - BrAC) was 0.068 mg/g and the 95% limits of agreement were -0.021 and 0.156 mg/g. The average BAC/BrAC ratio was 2448+/-540 (+/-S.D.) with a median of 2351 and 2.5th and 97.5th percentiles of 1836 and 4082. We found no significant gender-related differences in BAC/BrAC ratios, being 2553+/-576 for men and 2417+/-494 for women (t=1.34, P>0.05). The mean rate of ethanol disappearance from blood was 0.157+/-0.021 mg/(g per hour), which was very close to the elimination rate from breath of 0.161+/-0.021 mg/(2l per hour) (P>0.05). Breath-test results obtained with Intoxilyzer 5000S (mg/2l) were generally less than the coexisting concentrations of ethanol in venous blood

  16. 13CO2/12CO2 isotope ratio analysis in human breath using a 2 μm diode laser

    NASA Astrophysics Data System (ADS)

    Sun, Mingguo; Cao, Zhensong; Liu, Kun; Wang, Guishi; Tan, Tu; Gao, Xiaoming; Chen, Weidong; Yinbo, Huang; Ruizhong, Rao

    2015-04-01

    The bacterium H. pylori is believed to cause peptic ulcer. H. pylori infection in the human stomach can be diagnosed through a CO2 isotope ratio measure in exhaled breath. A laser spectrometer based on a distributed-feedback semiconductor diode laser at 2 μm is developed to measure the changes of 13CO2/12CO2 isotope ratio in exhaled breath sample with the CO2 concentration of ~4%. It is characterized by a simplified optical layout, in which a single detector and associated electronics are used to probe CO2 spectrum. A new type multi-passes cell with 12 cm long base length , 29 m optical path length in total and 280 cm3 volume is used in this work. The temperature and pressure are well controlled at 301.15 K and 6.66 kPa with fluctuation amplitude of 25 mK and 6.7 Pa, respectively. The best 13δ precision of 0.06o was achieved by using wavelet denoising and Kalman filter. The application of denoising and Kalman filter not only improved the signal to noise ratio, but also shorten the system response time.

  17. Air-breathing aerospace plane development essential: Hypersonic propulsion flight tests

    NASA Technical Reports Server (NTRS)

    Mehta, Unmeel B.

    1994-01-01

    Hypersonic air-breathing propulsion utilizing scramjets can fundamentally change transatmospheric accelerators for low earth-to-orbit and return transportation. The value and limitations of ground tests, of flight tests, and of computations are presented, and scramjet development requirements are discussed. It is proposed that near full-scale hypersonic propulsion flight tests are essential for developing a prototype hypersonic propulsion system and for developing computational-design technology so that it can be used for designing this system. In order to determine how these objectives should be achieved, some lessons learned from past programs are presented. A conceptual two-stage-to-orbit (TSTO) prototype/experimental aerospace plane is recommended as a means of providing access-to-space and for conducting flight tests. A road map for achieving these objectives is also presented.

  18. Solubility testing of actinides on breathing-zone and area air samples

    NASA Astrophysics Data System (ADS)

    Metzger, Robert Lawrence

    The solubility of inhaled radionuclides in the human lung is an important characteristic of the compounds needed to perform internal dosimetry assessments for exposed workers. A solubility testing method for uranium and several common actinides has been developed with sufficient sensitivity to allow profiles to be determined from routine breathing zone and area air samples in the workplace. Air samples are covered with a clean filter to form a filter-sample-filter sandwich which is immersed in an extracellular lung serum simulant solution. The sample is moved to a fresh beaker of the lung fluid simulant each day for one week, and then weekly until the end of the 28 day test period. The soak solutions are wet ashed with nitric acid and hydrogen peroxide to destroy the organic components of the lung simulant solution prior to extraction of the nuclides of interest directly into an extractive scintillator for subsequent counting on a Photon-Electron Rejecting Alpha Liquid Scintillation (PERALSsp°ler ) spectrometer. Solvent extraction methods utilizing the extractive scintillators have been developed for the isotopes of uranium, plutonium, and curium. The procedures normally produce an isotopic recovery greater than 95% and have been used to develop solubility profiles from air samples with 40 pCi or less of Usb3Osb8. This makes it possible to characterize solubility profiles in every section of operating facilities where airborne nuclides are found using common breathing zone air samples. The new method was evaluated by analyzing uranium compounds from two uranium mills whose product had been previously analyzed by in vitro solubility testing in the laboratory and in vivo solubility testing in rodents. The new technique compared well with the in vivo rodent solubility profiles. The method was then used to evaluate the solubility profiles in all process sections of an operating in situ uranium plant using breathing zone and area air samples collected during routine

  19. Breath biomarkers in toxicology.

    PubMed

    Pleil, Joachim D

    2016-11-01

    Exhaled breath has joined blood and urine as a valuable resource for sampling and analyzing biomarkers in human media for assessing exposure, uptake metabolism, and elimination of toxic chemicals. This article focuses current use of exhaled gas, aerosols, and vapor in human breath, the methods for collection, and ultimately the use of the resulting data. Some advantages of breath are the noninvasive and self-administered nature of collection, the essentially inexhaustible supply, and that breath sampling does not produce potentially infectious waste such as needles, wipes, bandages, and glassware. In contrast to blood and urine, breath samples can be collected on demand in rapid succession and so allow toxicokinetic observations of uptake and elimination in any time frame. Furthermore, new technologies now allow capturing condensed breath vapor directly, or just the aerosol fraction alone, to gain access to inorganic species, lung pH, proteins and protein fragments, cellular DNA, and whole microorganisms from the pulmonary microbiome. Future applications are discussed, especially the use of isotopically labeled probes, non-targeted (discovery) analysis, cellular level toxicity testing, and ultimately assessing "crowd breath" of groups of people and the relation to dose of airborne and other environmental chemicals at the population level.

  20. Effects of tidal volume on work of breathing during lung-protective ventilation in patients with acute lung injury and acute respiratory distress syndrome.

    PubMed

    Kallet, Richard H; Campbell, Andre R; Dicker, Rochelle A; Katz, Jeffrey A; Mackersie, Robert C

    2006-01-01

    To assess the effects of step-changes in tidal volume on work of breathing during lung-protective ventilation in patients with acute lung injury (ALI) or the acute respiratory distress syndrome (ARDS). Prospective, nonconsecutive patients with ALI/ARDS. Adult surgical, trauma, and medical intensive care units at a major inner-city, university-affiliated hospital. Ten patients with ALI/ARDS managed clinically with lung-protective ventilation. Five patients were ventilated at a progressively smaller tidal volume in 1 mL/kg steps between 8 and 5 mL/kg; five other patients were ventilated at a progressively larger tidal volume from 5 to 8 mL/kg. The volume mode was used with a flow rate of 75 L/min. Minute ventilation was maintained constant at each tidal volume setting. Afterward, patients were placed on continuous positive airway pressure for 1-2 mins to measure their spontaneous tidal volume. Work of breathing and other variables were measured with a pulmonary mechanics monitor (Bicore CP-100). Work of breathing progressively increased (0.86 +/- 0.32, 1.05 +/- 0.40, 1.22 +/- 0.36, and 1.57 +/- 0.43 J/L) at a tidal volume of 8, 7, 6, and 5 mL/kg, respectively. In nine of ten patients there was a strong negative correlation between work of breathing and the ventilator-to-patient tidal volume difference (R = -.75 to -.998). : The ventilator-delivered tidal volume exerts an independent influence on work of breathing during lung-protective ventilation in patients with ALI/ARDS. Patient work of breathing is inversely related to the difference between the ventilator-delivered tidal volume and patient-generated tidal volume during a brief trial of unassisted breathing.

  1. On the importance of developing a new generation of breath tests for Helicobacter pylori detection.

    PubMed

    Kushch, Ievgeniia; Korenev, Nikolai; Kamarchuk, Lyudmila; Pospelov, Alexander; Kravchenko, Andrey; Bajenov, Leonid; Kabulov, Mels; Amann, Anton; Kamarchuk, Gennadii

    2015-12-15

    State-of-the-art methods for non-invasive detection of the Helicobacter pylori (H. pylori) infection have been considered. A reported global tendency towards a non-decreasing prevalence of H. pylori worldwide could be co-influenced by the functional limitations of urea breath tests (UBTs), currently preferred for the non-invasive recognition of H. pylori in a clinical setting. Namely, the UBTs can demonstrate false-positive or false-negative results. Within this context, limitations of conventional clinically exploited H. pylori tests have been discussed to justify the existing need for the development of a new generation of breath tests for the detection of H. pylori and the differentiation of pathogenic and non-pathogenic strains of the bacterium. This paper presents the results of a pilot clinical study aimed at evaluating the development and diagnostic potential of a new method based on the detection of the non-urease products of H. pylori vital activity in exhaled gas. The characteristics of breath of adolescents with H. pylori-positive and H. pylori-negative functional dyspepsia, together with a consideration of the cytotoxin-associated gene A (CagA) status of H. pylori-positive subjects, have been determined for the first time using innovative point-contact nanosensor devices based on salts of the organic conductor tetracyanoquinodimethane (TCNQ). The clinical and diagnostic relevance of the response curves of the point-contact sensors was assessed. It was found that the recovery time of the point-contact sensors has a diagnostic value for differentiation of the H. pylori-associated peptic ulcer disease. The diagnostically significant elongation of the recovery time was even more pronounced in patients infected with CagA-positive H. pylori strains compared to the CagA-negative patients. Taking into account the operation of the point-contact sensors in the real-time mode, the obtained results are essential prerequisites for the development of a fast and

  2. Breathing exercises for dysfunctional breathing/hyperventilation syndrome in adults.

    PubMed

    Jones, Mandy; Harvey, Alex; Marston, Louise; O'Connell, Neil E

    2013-05-31

    Dysfunctional breathing/hyperventilation syndrome (DB/HVS) is a respiratory disorder, psychologically or physiologically based, involving breathing too deeply and/or too rapidly (hyperventilation) or erratic breathing interspersed with breath-holding or sighing (DB). DB/HVS can result in significant patient morbidity and an array of symptoms including breathlessness, chest tightness, dizziness, tremor and paraesthesia. DB/HVS has an estimated prevalence of 9.5% in the general adult population, however, there is little consensus regarding the most effective management of this patient group. (1) To determine whether breathing exercises in patients with DB/HVS have beneficial effects as measured by quality of life indices (2) To determine whether there are any adverse effects of breathing exercises in patients with DB/HVS SEARCH METHODS: We identified trials for consideration using both electronic and manual search strategies. We searched CENTRAL, MEDLINE, EMBASE, and four other databases. The latest search was in February 2013. We planned to include randomised, quasi-randomised or cluster randomised controlled trials (RCTs) in which breathing exercises, or a combined intervention including breathing exercises as a key component, were compared with either no treatment or another therapy that did not include breathing exercises in patients with DB/HVS. Observational studies, case studies and studies utilising a cross-over design were not eligible for inclusion.We considered any type of breathing exercise for inclusion in this review, such as breathing control, diaphragmatic breathing, yoga breathing, Buteyko breathing, biofeedback-guided breathing modification, yawn/sigh suppression. Programs where exercises were either supervised or unsupervised were eligible as were relaxation techniques and acute-episode management, as long as it was clear that breathing exercises were a key component of the intervention.We excluded any intervention without breathing exercises or

  3. Tunable Quantum Spin Liquidity in the 1 /6 th-Filled Breathing Kagome Lattice

    NASA Astrophysics Data System (ADS)

    Akbari-Sharbaf, A.; Sinclair, R.; Verrier, A.; Ziat, D.; Zhou, H. D.; Sun, X. F.; Quilliam, J. A.

    2018-06-01

    We present measurements on a series of materials, Li2 In1 -xScx Mo3 O8 , that can be described as a 1 /6 th-filled breathing kagome lattice. Substituting Sc for In generates chemical pressure which alters the breathing parameter nonmonotonically. Muon spin rotation experiments show that this chemical pressure tunes the system from antiferromagnetic long range order to a quantum spin liquid phase. A strong correlation with the breathing parameter implies that it is the dominant parameter controlling the level of magnetic frustration, with increased kagome symmetry generating the quantum spin liquid phase. Magnetic susceptibility measurements suggest that this is related to distinct types of charge order induced by changes in lattice symmetry, in line with the theory of Chen et al. [Phys. Rev. B 93, 245134 (2016), 10.1103/PhysRevB.93.245134]. The specific heat for samples at intermediate Sc concentration, which have the minimum breathing parameter, show consistency with the predicted U (1 ) quantum spin liquid.

  4. Fourier-based linear systems description of free-breathing pulmonary magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Capaldi, D. P. I.; Svenningsen, S.; Cunningham, I. A.; Parraga, G.

    2015-03-01

    Fourier-decomposition of free-breathing pulmonary magnetic resonance imaging (FDMRI) was recently piloted as a way to provide rapid quantitative pulmonary maps of ventilation and perfusion without the use of exogenous contrast agents. This method exploits fast pulmonary MRI acquisition of free-breathing proton (1H) pulmonary images and non-rigid registration to compensate for changes in position and shape of the thorax associated with breathing. In this way, ventilation imaging using conventional MRI systems can be undertaken but there has been no systematic evaluation of fundamental image quality measurements based on linear systems theory. We investigated the performance of free-breathing pulmonary ventilation imaging using a Fourier-based linear system description of each operation required to generate FDMRI ventilation maps. Twelve subjects with chronic obstructive pulmonary disease (COPD) or bronchiectasis underwent pulmonary function tests and MRI. Non-rigid registration was used to co-register the temporal series of pulmonary images. Pulmonary voxel intensities were aligned along a time axis and discrete Fourier transforms were performed on the periodic signal intensity pattern to generate frequency spectra. We determined the signal-to-noise ratio (SNR) of the FDMRI ventilation maps using a conventional approach (SNRC) and using the Fourier-based description (SNRF). Mean SNR was 4.7 ± 1.3 for subjects with bronchiectasis and 3.4 ± 1.8, for COPD subjects (p>.05). SNRF was significantly different than SNRC (p<.01). SNRF was approximately 50% of SNRC suggesting that the linear system model well-estimates the current approach.

  5. A simple test of one minute heart rate variability during deep breathing for evaluation of sympatovagal imbalance in hyperthyroidism.

    PubMed

    Shuvy, Mony; Arbelle, Jonathan E; Grosbard, Aviva; Katz, Amos

    2008-01-01

    Heart rate variability is a sensitive marker of cardiac sympathetic activity. To determine whether long-term hyperthyroidism induced by thyroxine suppressive therapy affects HRV. Nineteen patients treated with suppressive doses of thyroxin for thyroid cancer and 19 age-matched controls were enrolled. Thyroid function tests and 1 minute HRV were performed on all subjects and the results were compared between the groups. The 1 minute HRV was analyzed during deep breathing and defined as the difference in beats/minute between the shortest and the longest heart rate interval measured by eletrocardiographic recording during six cycles of deep breathing. One minute HRV during deep breathing was significantly lower among thyroxine-treated patients compared to healthy controls (25.6 +/- 10.5 vs. 34.3 +/- 12.6 beats/min, P < 0.05). There were no significant differences in mean, maximal and minimal heart rate between the groups. Thyroxine therapy administered for epithelial thyroid cancer resulted in subclinical hyperthyroidism and significantly decreased HRV due to autonomic dysfunction rather than basic elevated heart rate.

  6. Fiber-enhanced Raman multigas spectroscopy: a versatile tool for environmental gas sensing and breath analysis.

    PubMed

    Hanf, Stefan; Keiner, Robert; Yan, Di; Popp, Jürgen; Frosch, Torsten

    2014-06-03

    Versatile multigas analysis bears high potential for environmental sensing of climate relevant gases and noninvasive early stage diagnosis of disease states in human breath. In this contribution, a fiber-enhanced Raman spectroscopic (FERS) analysis of a suite of climate relevant atmospheric gases is presented, which allowed for reliable quantification of CH4, CO2, and N2O alongside N2 and O2 with just one single measurement. A highly improved analytical sensitivity was achieved, down to a sub-parts per million limit of detection with a high dynamic range of 6 orders of magnitude and within a second measurement time. The high potential of FERS for the detection of disease markers was demonstrated with the analysis of 27 nL of exhaled human breath. The natural isotopes (13)CO2 and (14)N(15)N were quantified at low levels, simultaneously with the major breath components N2, O2, and (12)CO2. The natural abundances of (13)CO2 and (14)N(15)N were experimentally quantified in very good agreement to theoretical values. A fiber adapter assembly and gas filling setup was designed for rapid and automated analysis of multigas compositions and their fluctuations within seconds and without the need for optical readjustment of the sensor arrangement. On the basis of the abilities of such miniaturized FERS system, we expect high potential for the diagnosis of clinically administered (13)C-labeled CO2 in human breath and also foresee high impact for disease detection via biologically vital nitrogen compounds.

  7. Walk test and school performance in mouth-breathing children.

    PubMed

    Boas, Ana Paula Dias Vilas; Marson, Fernando Augusto de Lima; Ribeiro, Maria Angela Gonçalves de Oliveira; Sakano, Eulália; Conti, Patricia Blau Margosian; Toro, Adyléia Dalbo Contrera; Ribeiro, José Dirceu

    2013-01-01

    In recent decades, many studies on mouth breathing (MB) have been published; however, little is known about many aspects of this syndrome, including severity, impact on physical and academic performances. Compare the physical performance in a six minutes walk test (6MWT) and the academic performance of MB and nasal-breathing (NB) children and adolescents. This is a descriptive, cross-sectional, and prospective study with MB and NB children submitted to the 6MWT and scholar performance assessment. We included 156 children, 87 girls (60 NB and 27 MB) and 69 boys (44 NB and 25 MB). Variables were analyzed during the 6MWT: heart rate (HR), respiratory rate, oxygen saturation, distance walked in six minutes and modified Borg scale. All the variables studied were statistically different between groups NB and MB, with the exception of school performance and HR in 6MWT. MB affects physical performance and not the academic performance, we noticed a changed pattern in the 6MWT in the MB group. Since the MBs in our study were classified as non-severe, other studies comparing the academic performance variables and 6MWT are needed to better understand the process of physical and academic performances in MB children.

  8. Synthesis and antimycobacterial and photosynthesis-inhibiting evaluation of 2-[(E)-2-substituted-ethenyl]-1,3-benzoxazoles.

    PubMed

    Imramovsky, Ales; Kozic, Jan; Pesko, Matus; Stolarikova, Jirina; Vinsova, Jarmila; Kralova, Katarina; Jampilek, Josef

    2014-01-01

    A series of twelve 2-[(E)-2-substituted-ethenyl]-1,3-benzoxazoles was designed. All the synthesized compounds were tested against three mycobacterial strains. The compounds were also evaluated for their ability to inhibit photosynthetic electron transport (PET) in spinach (Spinacia oleracea L.) chloroplasts. 2-[(E)-2-(4-Methoxyphenyl)ethenyl]-1,3-benzoxazole, 2-[(E)-2-(2,3-dihydro-1-benzofuran-5-yl)ethenyl]-1,3-benzoxazole and 2-{(E)-2-[4-(methylsulfanyl)phenyl]ethenyl}-1,3-benzoxazole showed the highest activity against M. tuberculosis, M. kansasii, and M. avium, and they demonstrated significantly higher activity against M. avium and M. kansasii than isoniazid. The PET-inhibiting activity of the most active ortho-substituted compound 2-[(E)-2-(2-methoxyphenyl)ethenyl]-1,3-benzoxazole was IC₅₀ = 76.3 μmol/L, while the PET-inhibiting activity of para-substituted compounds was significantly lower. The site of inhibitory action of tested compounds is situated on the donor side of photosystem II. The structure-activity relationships are discussed.

  9. Effort of breathing in children receiving high-flow nasal cannula.

    PubMed

    Rubin, Sarah; Ghuman, Anoopindar; Deakers, Timothy; Khemani, Robinder; Ross, Patrick; Newth, Christopher J

    2014-01-01

    High-flow humidified nasal cannula is often used to provide noninvasive respiratory support in children. The effect of high-flow humidified nasal cannula on effort of breathing in children has not been objectively studied, and the mechanism by which respiratory support is provided remains unclear. This study uses an objective measure of effort of breathing (Pressure. Rate Product) to evaluate high-flow humidified nasal cannula in critically ill children. Prospective cohort study. Quaternary care free-standing academic children's hospital. ICU patients younger than 18 years receiving high-flow humidified nasal cannula or whom the medical team planned to extubate to high-flow humidified nasal cannula within 72 hours of enrollment. An esophageal pressure monitoring catheter was placed to measure pleural pressures via a Bicore CP-100 pulmonary mechanics monitor. Change in pleural pressure (ΔPes) and respiratory rate were measured on high-flow humidified nasal cannula at 2, 5, and 8 L/min. ΔPes and respiratory rate were multiplied to generate the Pressure.Rate Product, a well-established objective measure of effort of breathing. Baseline Pes, defined as pleural pressure at end exhalation during tidal breathing, reflected the positive pressure generated on each level of respiratory support. Twenty-five patients had measurements on high-flow humidified nasal cannula. Median age was 6.5 months (interquartile range, 1.3-15.5 mo). Median Pressure,Rate Product was lower on high-flow humidified nasal cannula 8 L/min (median, 329 cm H2O·min; interquartile range, 195-402) compared with high-flow humidified nasal cannula 5 L/min (median, 341; interquartile range, 232-475; p = 0.007) or high-flow humidified nasal cannula 2 L/min (median, 421; interquartile range, 233-621; p < 0.0001) and was lower on high-flow humidified nasal cannula 5 L/min compared with high-flow humidified nasal cannula 2 L/min (p = 0.01). Baseline Pes was higher on high-flow humidified nasal

  10. Breath holding spell

    MedlinePlus

    ... such as Riley-Day syndrome or Rett syndrome Iron deficiency anemia A family history of breath holding spells ( ... tests may be done to check for an iron deficiency. Other tests that may be done include: EKG ...

  11. Slow Breathing and Hypoxic Challenge: Cardiorespiratory Consequences and Their Central Neural Substrates

    PubMed Central

    Critchley, Hugo D.; Nicotra, Alessia; Chiesa, Patrizia A.; Nagai, Yoko; Gray, Marcus A.; Minati, Ludovico; Bernardi, Luciano

    2015-01-01

    Controlled slow breathing (at 6/min, a rate frequently adopted during yoga practice) can benefit cardiovascular function, including responses to hypoxia. We tested the neural substrates of cardiorespiratory control in humans during volitional controlled breathing and hypoxic challenge using functional magnetic resonance imaging (fMRI). Twenty healthy volunteers were scanned during paced (slow and normal rate) breathing and during spontaneous breathing of normoxic and hypoxic (13% inspired O2) air. Cardiovascular and respiratory measures were acquired concurrently, including beat-to-beat blood pressure from a subset of participants (N = 7). Slow breathing was associated with increased tidal ventilatory volume. Induced hypoxia raised heart rate and suppressed heart rate variability. Within the brain, slow breathing activated dorsal pons, periaqueductal grey matter, cerebellum, hypothalamus, thalamus and lateral and anterior insular cortices. Blocks of hypoxia activated mid pons, bilateral amygdalae, anterior insular and occipitotemporal cortices. Interaction between slow breathing and hypoxia was expressed in ventral striatal and frontal polar activity. Across conditions, within brainstem, dorsal medullary and pontine activity correlated with tidal volume and inversely with heart rate. Activity in rostroventral medulla correlated with beat-to-beat blood pressure and heart rate variability. Widespread insula and striatal activity tracked decreases in heart rate, while subregions of insular cortex correlated with momentary increases in tidal volume. Our findings define slow breathing effects on central and cardiovascular responses to hypoxic challenge. They highlight the recruitment of discrete brainstem nuclei to cardiorespiratory control, and the engagement of corticostriatal circuitry in support of physiological responses that accompany breathing regulation during hypoxic challenge. PMID:25973923

  12. 49 CFR 40.245 - What is the procedure for an alcohol screening test using a saliva ASD or a breath tube ASD?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... test using a saliva ASD or a breath tube ASD? 40.245 Section 40.245 Transportation Office of the... Alcohol Screening Tests § 40.245 What is the procedure for an alcohol screening test using a saliva ASD or a breath tube ASD? (a) As the STT or BAT, you must take the following steps when using the saliva...

  13. Control of gill ventilation and air-breathing in the bowfin amia calva

    PubMed

    Hedrick; Jones

    1999-01-01

    The purpose of this study was to investigate the roles of branchial and gas bladder reflex pathways in the control of gill ventilation and air-breathing in the bowfin Amia calva. We have previously determined that bowfin use two distinct air-breathing mechanisms to ventilate the gas bladder: type I air breaths are characterized by exhalation followed by inhalation, are stimulated by aquatic or aerial hypoxia and appear to regulate O2 gas exchange; type II air breaths are characterized by inhalation alone and possibly regulate gas bladder volume and buoyancy. In the present study, we test the hypotheses (1) that gill ventilation and type I air breaths are controlled by O2-sensitive chemoreceptors located in the branchial region, and (2) that type II air breaths are controlled by gas bladder mechanosensitive stretch receptors. Hypothesis 1 was tested by examining the effects of partial or complete branchial denervation of cranial nerves IX and X to the gill arches on gill ventilation frequency (fg) and the proportion of type I air breaths during normoxia and hypoxia; hypothesis II was tested by gas bladder inflation and deflation. Following complete bilateral branchial denervation, fg did not differ from that of sham-operated control fish; in addition, fg was not significantly affected by aquatic hypoxia in sham-operated or denervated fish. In sham-operated fish, aquatic hypoxia significantly increased overall air-breathing frequency (fab) and the percentage of type I breaths. In fish with complete IX-X branchial denervation, fab was also significantly increased during aquatic hypoxia, but there were equal percentages of type I and type II air breaths. Branchial denervation did not affect the frequency of type I air breaths during aquatic hypoxia. Gas bladder deflation via an indwelling catheter resulted in type II breaths almost exclusively; furthermore, fab was significantly correlated with the volume removed from the gas bladder, suggesting a volume

  14. Protein requirements of healthy pregnant women during early and late gestation are higher than current recommendations.

    PubMed

    Stephens, Trina V; Payne, Magdalene; Ball, Ronald O; Pencharz, Paul B; Elango, Rajavel

    2015-01-01

    Adequate maternal dietary protein intake is necessary for healthy pregnancy. However, current protein intake recommendations for healthy pregnant women are based on factorial calculations of nitrogen balance data derived from nonpregnant adults. Thus, an estimate of protein requirements based on pregnancy-specific data is needed. The objective of this study was to determine protein requirements of healthy pregnant women at 11-20 (early) and 31-38 (late) wk of gestation through use of the indicator amino acid oxidation method. Twenty-nine healthy women (24-37 y) each randomly received a different test protein intake (range: 0.22-2.56 g · kg(-1) · d(-1)) during each study day in early (n = 35 observations in 17 women) and late (n = 43 observations in 19 women) gestation; 7 women participated in both early and late gestation studies. The diets were isocaloric and provided energy at 1.7 × resting energy expenditure. Protein was given as a crystalline amino acid mixture based on egg protein composition, except phenylalanine and tyrosine, which were maintained constant across intakes. Protein requirements were determined by measuring the oxidation rate of L-[1-(13)C]phenylalanine to (13)CO2 (F(13)CO2). Breath and urine samples were collected at baseline and isotopic steady state. Linear regression crossover analysis identified a breakpoint (requirement) at minimal F(13)CO2 in response to different protein intakes. The estimated average requirement (EAR) for protein in early and late gestation was determined to be 1.22 (R(2) = 0.60; 95% CI: 0.79, 1.66 g · kg(-1) · d(-1)) and 1.52 g · kg(-1) · d(-1) (R(2) = 0.63; 95% CI: 1.28, 1.77 g · kg(-1) · d(-1)), respectively. These estimates are considerably higher than the EAR of 0.88 g · kg(-1) · d(-1) currently recommended by the Dietary Reference Intakes. To our knowledge, this study is the first to directly estimate gestational stage-specific protein requirements in healthy pregnant women and suggests that current

  15. Inside anesthesia breathing circuits: time to reach a set sevoflurane concentration in toddlers and newborns: simulation using a test lung.

    PubMed

    Kern, Delphine; Larcher, Claire; Basset, Bertrand; Alacoque, Xavier; Fesseau, Rose; Samii, Kamran; Minville, Vincent; Fourcade, Olivier

    2012-08-01

    We measured the time it takes to reach the desired inspired anesthetic concentration using the Primus (Drägerwerk, AG, Lübeck, Germany) and the Avance (GE Datex-Ohmeda, Munich, Germany) anesthesia machines with toddler and newborn ventilation settings. The time to reach 95% of inspired target sevoflurane concentration was measured during wash-in from 0 to 6 vol% sevoflurane and during wash-out from 6 to 0 vol% with fresh gas flows equal to 1 and 2 times the minute ventilation. The Avance was faster than the Primus (65 seconds [95% confidence interval (CI): 55 to 78] vs 310 seconds [95% CI: 261 to 359]) at 1.5 L/min fresh gas flow, tidal volume of 50 mL, and 30 breaths/min. Times were shorter by the same magnitude at higher fresh gas flows and higher minute ventilation rates. The effect of doubling fresh gas flow was variable and less than expected. The Primus is slower during newborn than toddler ventilation, whereas the Avance's response time was the same for newborn and toddler ventilation. Our data confirm that the time to reach the target-inspired anesthetic concentration depends on breathing circuit volume, fresh gas flow, and minute ventilation.

  16. Training in multiple breath washout testing for respiratory physiotherapists.

    PubMed

    O'Neill, Katherine; Elborn, J Stuart; Tunney, Michael M; O'Neill, Philip; Rowan, Stephen; Martin, Susan; Bradley, Judy M

    2018-03-01

    The development of multiple breath washout (MBW) testing in respiratory disease highlights the need for increased awareness amongst respiratory physiotherapists and a potential opportunity for professional development in the use of an important outcome measure for clinical trials. To rationalise how MBW may be a useful assessment tool for respiratory physiotherapists and to describe a local MBW training and certification programme for physiotherapists. The respiratory Multidisciplinary Team in the Belfast Health and Social Care Trust (BHSCT) identified a need for MBW testing to be available to facilitate clinical research and assessment. A 2day training programme consisting of prereading preparation, self-directed learning, theory presentations, practical demonstrations and hands-on practice was developed and delivered. All participants underwent a certification process. We have demonstrated the successful training and certification of clinical and research physiotherapists and encourage other respiratory physiotherapists to consider MBW test training. Copyright © 2017 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  17. Changes in cardiac output during swimming and aquatic hypoxia in the air-breathing Pacific tarpon.

    PubMed

    Clark, T D; Seymour, R S; Christian, K; Wells, R M G; Baldwin, J; Farrell, A P

    2007-11-01

    Pacific tarpon (Megalops cyprinoides) use a modified gas bladder as an air-breathing organ (ABO). We examined changes in cardiac output (V(b)) associated with increases in air-breathing that accompany exercise and aquatic hypoxia. Juvenile (0.49 kg) and adult (1.21 kg) tarpon were allowed to recover in a swim flume at 27 degrees C after being instrumented with a Doppler flow probe around the ventral aorta to monitor V(b) and with a fibre-optic oxygen sensor in the ABO to monitor air-breathing frequency. Under normoxic conditions and in both juveniles and adults, routine air-breathing frequency was 0.03 breaths min(-1) and V(b) was about 15 mL min(-1) kg(-1). Normoxic exercise (swimming at about 1.1 body lengths s(-1)) increased air-breathing frequency by 8-fold in both groups (reaching 0.23 breaths min(-1)) and increased V(b) by 3-fold for juveniles and 2-fold for adults. Hypoxic exposure (2 kPa O2) at rest increased air-breathing frequency 19-fold (to around 0.53 breaths min(-1)) in both groups, and while V(b) again increased 3-fold in resting juvenile fish, V(b) was unchanged in resting adult fish. Exercise in hypoxia increased air-breathing frequency 35-fold (to 0.95 breaths min(-1)) in comparison with resting normoxic fish. While juvenile fish increased V(b) nearly 2-fold with exercise in hypoxia, adult fish maintained the same V(b) irrespective of exercise state and became agitated in comparison. These results imply that air-breathing during exercise and hypoxia can benefit oxygen delivery, but to differing degrees in juvenile and adult tarpon. We discuss this difference in the context of myocardial oxygen supply.

  18. Posttest REALP4 analysis of LOFT experiment L1-3A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, J.R.; Holmstrom, H.L.O.

    This report presents selected results of posttest RELAP4 modeling of LOFT loss-of-coolant experiment L1-3A, a double-ended isothermal cold leg break with lower plenum emergency core coolant injection. Comparisons are presented between the pretest prediction, the posttest analysis, and the experimental data. It is concluded that pressurizer modeling is important for accurately predicting system behavior during the initial portion of saturated blowdown. Using measured initial conditions rather than nominal specified initial conditions did not influence the system model results significantly. Using finer nodalization in the reactor vessel improved the prediction of the system pressure history by minimizing steam condensation effects. Unequalmore » steam condensation between the downcomer and core volumes appear to cause the manometer oscillations observed in both the pretest and posttest RELAP4 analysis.« less

  19. Air sampling unit for breath analyzers

    NASA Astrophysics Data System (ADS)

    Szabra, Dariusz; Prokopiuk, Artur; Mikołajczyk, Janusz; Ligor, Tomasz; Buszewski, Bogusław; Bielecki, Zbigniew

    2017-11-01

    The paper presents a portable breath sampling unit (BSU) for human breath analyzers. The developed unit can be used to probe air from the upper airway and alveolar for clinical and science studies. The BSU is able to operate as a patient interface device for most types of breath analyzers. Its main task is to separate and to collect the selected phases of the exhaled air. To monitor the so-called I, II, or III phase and to identify the airflow from the upper and lower parts of the human respiratory system, the unit performs measurements of the exhaled CO2 (ECO2) in the concentration range of 0%-20% (0-150 mm Hg). It can work in both on-line and off-line modes according to American Thoracic Society/European Respiratory Society standards. A Tedlar bag with a volume of 5 dm3 is mounted as a BSU sample container. This volume allows us to collect ca. 1-25 selected breath phases. At the user panel, each step of the unit operation is visualized by LED indicators. This helps us to regulate the natural breathing cycle of the patient. There is also an operator's panel to ensure monitoring and configuration setup of the unit parameters. The operation of the breath sampling unit was preliminarily verified using the gas chromatography/mass spectrometry (GC/MS) laboratory setup. At this setup, volatile organic compounds were extracted by solid phase microextraction. The tests were performed by the comparison of GC/MS signals from both exhaled nitric oxide and isoprene analyses for three breath phases. The functionality of the unit was proven because there was an observed increase in the signal level in the case of the III phase (approximately 40%). The described work made it possible to construct a prototype of a very efficient breath sampling unit dedicated to breath sample analyzers.

  20. 3. "TEST STAND NO. 13, EXCAVATION PLAN & SECTIONS." Specifications ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. "TEST STAND NO. 1-3, EXCAVATION PLAN & SECTIONS." Specifications No. ENG 04-353-50-10; Drawing No. 60-0906; no sheet number within title block; D.O. SERIES 1109/10. Stamped: AS BUILT. No revisions or revision dates. Last work date on this drawing "Checked by EAG, 1/31/49." Though this drawing is specific to Test Stand 1-3, it also illustrates the general methods used for excavation design and retaining wall construction at Test Stand 1-5. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-3, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  1. Effects of Breathing Resistance on Resting Ventilatory Sensitivity to CO2

    DTIC Science & Technology

    2014-08-12

    be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE...elements were designed to generate work of breathing per tidal volume of 1 kPa when minute ventilation was 100 L/min. Resistance caused no systematic...the laboratory is considerably lower and that end- tidal PCO2 is higher with resistance in the breathing circuit than without it.2, 3 Work has

  2. Limonene in exhaled breath is elevated in hepatic encephalopathy

    PubMed Central

    O’Hara, M E; Fernández del Río, R; Holt, A; Pemberton, P; Shah, T; Whitehouse, T; Mayhew, C A

    2016-01-01

    Abstract Breath samples were taken from 31 patients with liver disease and 30 controls in a clinical setting and proton transfer reaction quadrupole mass spectrometry (PTR-Quad-MS) used to measure the concentration of volatile organic compounds (VOCs). All patients had cirrhosis of various etiologies, with some also suffering from hepatocellular cancer (HCC) and/or hepatic encephalopathy (HE). Breath limonene was higher in patients with No-HCC than with HCC, median (lower/upper quartile) 14.2 (7.2/60.1) versus 3.6 (2.0/13.7) and 1.5 (1.1/2.3) nmol mol−1 in controls. This may reflect disease severity, as those with No-HCC had significantly higher UKELD (United Kingdom model for End stage Liver Disease) scores. Patients with HE were categorized as having HE symptoms presently, having a history but no current symptoms and having neither history nor current symptoms. Breath limonene in these groups was median (lower/upper quartile) 46.0 (14.0/103), 4.2 (2.6/6.4) and 7.2 (2.0/19.1) nmol mol−1, respectively. The higher concentration of limonene in those with current symptoms of HE than with a history but no current symptoms cannot be explained by disease severity as their UKELD scores were not significantly different. Longitudinal data from two patients admitted to hospital with HE show a large intra-subject variation in breath limonene, median (range) 18 (10–44) and 42 (32–58) nmol mol−1. PMID:27869108

  3. Studies regarding the mechanism of false negative urea breath tests with proton pump inhibitors.

    PubMed

    Graham, David Y; Opekun, Antone R; Hammoud, Fadi; Yamaoka, Yoshio; Reddy, Rita; Osato, Michael S; El-Zimaity, Hala M T

    2003-05-01

    The mechanism of false negative urea breath tests (UBTs) results among proton pump inhibitor (PPI) users is unknown. We studied the time course of PPI-associated negative UBT, the relation to Helicobacter pylori density, and whether gastric acidification would prevent false negative UBT results. In the UBT experiment, H. pylori-infected volunteers received omeprazole 20 mg b.i.d. for 13.5 days. UBTs with citric acid were done before, after 6.5 days of PPI, and 1, 2, 4, 7, and 14 days after therapy. In the culture and histology experiment, after a wash-out of >5 months, nine of the original subjects were rechallenged with omeprazole for 6.5 days. Antral and corpus biopsies for histology and culture were done before and 1 day after PPI administration. Thirty subjects (mean age 42 yr) were enrolled. UBTs were significantly reduced on day 6.5 (p = 0.031); 10 subjects (33%) developed transient negative UBTs. The UBT recovered in all but one subject by the fourth day post-PPI and in all subjects by day 14. In the culture and histology experiment, upon PPI rechallenge, three of nine subjects (33%) had negative UBTs. H. pylori density, whether measured by culture or histology, decreased with PPI therapy; antral biopsies became histologically negative in five subjects and corpus biopsies in three subjects. PPI-induced negative UBT results were related to the anti-H. pylori effect of the PPI. Acidification of the stomach did not prevent false negative UBT results. Three days is likely the minimum delay from stopping PPI until one should perform a test for active infection. A delay of 14 days is preferred.

  4. Positive or negative fructose breath test results do not predict response to fructose restricted diet in children with recurrent abdominal pain: results from a prospective randomized trial.

    PubMed

    Wirth, S; Klodt, C; Wintermeyer, P; Berrang, J; Hensel, K; Langer, T; Heusch, A

    2014-09-01

    To perform a prospective, blinded, randomized interventional trial in patients with recurrent abdominal pain. The primary endpoint was to determine the abdominal pain intensity after 2 weeks of fructose restricted diet. Secondary endpoints were changes of pain frequency and a secondary symptom score (SSS). 103 individuals with recurrent abdominal pain for more than 3 months were randomized. 51 patients were allocated to group A (diet) and 52 to group B (no diet). 2 weeks later the patients underwent hydrogen breath test and were assigned to the test positive or negative group to identify patients with fructose malabsorption. 2 weeks after intervention the pain score decreased significantly from a median 5.5 in group A to 4 and did not change significantly in group B (5.3 to 5). In group A both patients with positive and negative breath tests had a significant lower pain score (-2 and -1.75, respectively). Frequency of abdominal pain decreased in both groups but without significant difference, SSS improved only in group A from median 6 to 3.5. Positive breath test was no predicting factor, neither was abdominal pain during the test. Fructose restricted diet in children and adolescents with recurrent abdominal pain may be of benefit to improve both abdominal pain symptoms and other secondary symptoms. Since a negative breath test result does not exclude a positive response to fructose restriction, the hydrogen breath test does not seem to be the appropriate diagnostic mean to predict the response to the diet. © Georg Thieme Verlag KG Stuttgart · New York.

  5. Stable Breathing in Patients With Obstructive Sleep Apnea Is Associated With Increased Effort but Not Lowered Metabolic Rate.

    PubMed

    de Melo, Camila M; Taranto-Montemurro, Luigi; Butler, James P; White, David P; Loring, Stephen H; Azarbarzin, Ali; Marques, Melania; Berger, Philip J; Wellman, Andrew; Sands, Scott A

    2017-10-01

    In principle, if metabolic rate were to fall during sleep in a patient with obstructive sleep apnea (OSA), ventilatory requirements could be met without increased respiratory effort thereby favoring stable breathing. Indeed, most patients achieve periods of stable flow-limited breathing without respiratory events for periods during the night for reasons that are unclear. Thus, we tested the hypothesis that in patients with OSA, periods of stable breathing occur when metabolic rate (VO2) declines. Twelve OSA patients (apnea-hypopnea index >15 events/h) completed overnight polysomnography including measurements of VO2 (using ventilation and intranasal PO2) and respiratory effort (esophageal pressure). Contrary to our hypothesis, VO2 did not differ between stable and unstable breathing periods in non-REM stage 2 (208 ± 20 vs. 213 ± 18 mL/min), despite elevated respiratory effort during stable breathing (26 ± 2 versus 23 ± 2 cmH2O, p = .03). However, VO2 was lowered during deeper sleep (244 to 179 mL/min from non-REM stages 1 to 3, p = .04) in conjunction with more stable breathing. Further analysis revealed that airflow obstruction curtailed metabolism in both stable and unstable periods, since CPAP increased VO2 by 14% in both cases (p = .02, .03, respectively). Patients whose VO2 fell most during sleep avoided an increase in PCO2 and respiratory effort. OSA patients typically convert from unstable to stable breathing without lowering metabolic rate. During sleep, OSA patients labor with increased respiratory effort but fail to satisfy metabolic demand even in the absence of overt respiratory events. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  6. Regulation of L-type CaV1.3 channel activity and insulin secretion by the cGMP-PKG signaling pathway

    PubMed Central

    Sandoval, Alejandro; Duran, Paz; Gandini, María A.; Andrade, Arturo; Almanza, Angélica; Kaja, Simon; Felix, Ricardo

    2018-01-01

    cGMP is a second messenger widely used in the nervous system and other tissues. One of the major effectors for cGMP is the serine/threonine protein kinase, cGMP-dependent protein kinase (PKG), which catalyzes the phosphorylation of a variety of proteins including ion channels. Previously, it has been shown that the cGMP-PKG signaling pathway inhibits Ca2+ currents in rat vestibular hair cells and chromaffin cells. This current allegedly flow through voltage-gated CaV1.3L-type Ca2+ channels, and is important for controlling vestibular hair cell sensory function and catecholamine secretion, respectively. Here, we show that native L-type channels in the insulin-secreting RIN-m5F cell line, and recombinant CaV1.3 channels heterologously expressed in HEK-293 cells, are regulatory targets of the cGMP-PKG signaling cascade. Our results indicate that the CaVα1 ion-conducting subunit of the CaV1.3 channels is highly expressed in RIN-m5F cells and that the application of 8-Br-cGMP, a membrane-permeable analogue of cGMP, significantly inhibits Ca2+ macroscopic currents and impair insulin release stimulated with high K+. In addition, KT-5823, a specific inhibitor of PKG, prevents the current inhibition generated by 8-Br-cGMP in the heterologous expression system. Interestingly, mutating the putative phosphorylation sites to residues resistant to phosphorylation showed that the relevant PKG sites for CaV1.3 L-type channel regulation centers on two amino acid residues, Ser793 and Ser860, located in the intracellular loop connecting the II and III repeats of the CaVα1 pore-forming subunit of the channel. These findings unveil a novel mechanism for how the cGMP-PKG signaling pathway may regulate CaV1.3 channels and contribute to regulate insulin secretion. PMID:28807144

  7. Cav1.2, but not Cav1.3, L-type calcium channel subtype mediates nicotine-induced conditioned place preference in miceo.

    PubMed

    Liu, Yudan; Harding, Meghan; Dore, Jules; Chen, Xihua

    2017-04-03

    Nicotine use is one of the most common forms of drug addiction. Although L-type calcium channels (LTCCs) are involved in nicotine addiction, the contribution of the two primary LTCC subtypes (Ca v 1.2 and 1.3) is unknown. This study aims to determine the contribution of these two LTCC subtypes to nicotine-induced conditioned place preference (CPP) responses by using transgenic mouse models that do not express Ca v 1.3 (Ca v 1.3 -/- ) or contain a mutation in the dihydropyridine (DHP) site of the Ca v 1.2 (Ca v 1.2DHP -/- ). We found a hyperbolic dose dependent nicotine (0.1-1mg/kg; 0.5mg/kg optimum) effect on place preference in wild type (WT) mice, that could be prevented by the DHP LTCC blocker nifedipine pretreatment. Similarly, Ca v 1.3 -/- mice showed nicotine-induced place preference which was antagonized by nifedipine. In contrast, nifedipine pretreatment of Ca v 1.2DHP -/- mice had no effect on nicotine-induced CPP responses, suggesting an involvement of Ca v 1.2 subtype in the nicotine-induced CPP response. Nifedipine alone failed to produce either conditioned place aversion or CPP in WT mice. These results collectively indicate Ca v 1.2, but not Ca v 1.3 LTCC subtype regulates, at least in part, the reinforcing effects of nicotine use. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. C-terminal modulatory domain controls coupling of voltage-sensing to pore opening in Cav1.3 L-type Ca(2+) channels.

    PubMed

    Lieb, Andreas; Ortner, Nadine; Striessnig, Jörg

    2014-04-01

    Activity of voltage-gated Cav1.3 L-type Ca(2+) channels is required for proper hearing as well as sinoatrial node and brain function. This critically depends on their negative activation voltage range, which is further fine-tuned by alternative splicing. Shorter variants miss a C-terminal regulatory domain (CTM), which allows them to activate at even more negative potentials than C-terminally long-splice variants. It is at present unclear whether this is due to an increased voltage sensitivity of the Cav1.3 voltage-sensing domain, or an enhanced coupling of voltage-sensor conformational changes to the subsequent opening of the activation gate. We studied the voltage-dependence of voltage-sensor charge movement (QON-V) and of current activation (ICa-V) of the long (Cav1.3L) and a short Cav1.3 splice variant (Cav1.342A) expressed in tsA-201 cells using whole cell patch-clamp. Charge movement (QON) of Cav1.3L displayed a much steeper voltage-dependence and a more negative half-maximal activation voltage than Cav1.2 and Cav3.1. However, a significantly higher fraction of the total charge had to move for activation of Cav1.3 half-maximal conductance (Cav1.3: 68%; Cav1.2: 52%; Cav3.1: 22%). This indicated a weaker coupling of Cav1.3 voltage-sensor charge movement to pore opening. However, the coupling efficiency was strengthened in the absence of the CTM in Cav1.342A, thereby shifting ICa-V by 7.2 mV to potentials that were more negative without changing QON-V. We independently show that the presence of intracellular organic cations (such as n-methyl-D-glucamine) induces a pronounced negative shift of QON-V and a more negative activation of ICa-V of all three channels. These findings illustrate that the voltage sensors of Cav1.3 channels respond more sensitively to depolarization than those of Cav1.2 or Cav3.1. Weak coupling of voltage sensing to pore opening is enhanced in the absence of the CTM, allowing short Cav1.342A splice variants to activate at lower voltages

  9. Use of pump current modulation of diode laser for increased sensitivity of detection of 13СO2 in human exhaled breath

    NASA Astrophysics Data System (ADS)

    Kireev, S. V.; Kondrashov, A. A.; Shnyrev, S. L.; Safagaraev, A. P.

    2018-03-01

    This paper reports that the use of a lock-in detection technique, when the pump current modulation of a diode laser is operating near the wavelength of 2 µm, allows the improvement of the sensitivity of the online detection of 13СO2 in expired air by more than three orders of magnitude. The sensitivity of the 13СO2 detected in the paper is 60 ppb with an error of 13СO2 concentration measured in the exhaled breath at the level of 2.9% for an optical path length of 60 cm.

  10. A comparison of breath- and blood-alcohol test results from real-life policing situations: a one-year study of data from the Central Hessian police district in Germany.

    PubMed

    Roiu, Immanuel; Birngruber, Christoph G; Spencer, Victoria C; Wollersen, Heike; Dettmeyer, Reinhard; Verhoff, Marcel A

    2013-10-10

    So far, studies investigating the comparability of breath alcohol concentration (BrAC) with blood alcohol concentration (BAC) have focused on the accuracy of BrAC testing instruments. The presented study, conducted with cases from the district of the Middle Hessian Police Headquarters, is to the best of our knowledge the first to compare both methods under real-life conditions in normal policing situations. For a 1-year period, alcohol-impaired drunk-driving suspects, who were by criminal procedure required to give a blood sample, were offered a voluntary, additional BrAC test with a "Dräger Alcotest 7110 Evidential". The BrAC test was to be administered as soon as possible after the suspect had been apprehended, without, however, delaying the collection of the blood sample. Ninety-two cases could be included in our study. In 30 cases, a blood sample was not taken; in 11 cases, a BrAC test could not be performed. In the remaining 51 cases, we found the following pairings of BrAC and BAC results: BrAC≥0.55 mg/l and BAC≥1.1‰ (n=39); 0.25 mg/l≤BrAC<0.55 mg/l and 0.5‰≤BAC<1.1‰ (n=5); BrAC≥0.55 mg/l and BAC<1.1‰ (n=4); BrAC<0.55 mg/l and BAC≥1.1‰ (n=3). The mean value for the conversion factor, Q, was 2.12‰l/mg. In accord with numerous other studies, our study results would suggest a value of 2.1l/mg to German legislature as a new statutory value for Q. In borderline cases, of which there were already 7 in our study with 51 cases, suspects could benefit both from a BrAC test or a BAC test, with the benefit lastly depending more on early testing time than on the test method used. Our results support the call for the earliest possible measurement of alcohol concentration values after a drunk driving offense was committed. In some situations, this can probably only be accomplished with BrAC testing. A supplementary blood sample and BAC testing could compensate for the known weaknesses of BrAC testing. Thus, the complementary use of both methods

  11. Lack of inhibitory effect of cimetidine on caffeine metabolism in children using the caffeine breath test

    PubMed Central

    Parker, A.C.; Pritchard, P.; Preston, T.; Dalzell, A.M.; Choonara, I.

    1997-01-01

    Aims To study the potential drug interaction between cimetidine and caffeine in a group of children who received cimetidine for gastritis. Methods The caffeine breath test was carried out prior to the administration of cimetidine and after 2–3 weeks therapy. The children (n=1) received 300–800 mg cimetidine daily (11–36 mg kg−1 day−1 ). Results There was no significant change in the 2 h cumulative labelled CO2 following the administration of cimetidine (mean values 5.61% before and 4.87% during cimetidine; Student’s t-test P >0.2). Conclusions Cimetidine did not have an inhibitory effect on the metabolism of caffeine in this group of children studied. PMID:9159560

  12. The effect of deep inspiration breath-hold on tumour oxygenation.

    PubMed

    Aquino-Parsons, C; Ries, C R; Minchinton, A I; D'yachkova, Y

    2003-10-01

    To investigate the influence of deep inspiration breath-hold on the oxygen tension of in-vivo tumours measured using an Eppendorf pO2 histograph. Patients with accessible primary or metastatic tumours > or = 2 cm diameter were entered into a protocol measuring tumour oxygenation with an Eppendorf pO2 histograph during normal breathing (NB) and deep inspiration breath-hold (DIBH). Change in oxygen tension was assessed using the Wilcoxon Signed Ranks test. Thirty patients were entered in to this protocol. The median maximum tumour dimension was 4 cm. The median of the median pO2 of these tumours was 18 mmHg. Tumours were assessed during NB and DIBH. Oxygen tension measurements along 1-3 pairs of tracks per tumour (median of 2) were obtained. The median number of measurements per track was 30 for NB and 29 for DIBH (range 17-59). In six tumours, the values during NB were significantly higher than during DIBH, whereas, for six other tumours, the relationship was the opposite; for the remaining 18 patients, no significant difference was observed. These data show heterogeneity of tumour oxygenation seen with in-situ tumours both at baseline and as a result of DIBH. No systematic change in the Eppendorf pO2 measurements was seen as a result of DIBH; however, the individual tumour responses to DIBH varied dramatically.

  13. Influence of Very High Breathing Resistance on Exercise Tolerance, Part 1 - Dry Exercise

    DTIC Science & Technology

    2016-01-01

    Influence of Very High Breathing Resistance on Exercise Tolerance, Part 1 – Dry Exercise Authors...Tolerance, Part 1 – Dry Exercise 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Warkander D...exercise (60% of peak O2 consumption) on a cycle ergometer on dry land at sea level. R was such that the work of breathing per volume (volume-averaged

  14. The effect of consistent practice of yogic breathing exercises on the human cardiorespiratory system.

    PubMed

    McKay, Joshua A A; McCulloch, Cara L; Querido, Jordan S; Foster, Glen E; Koehle, Michael S; Sheel, A William

    2016-11-01

    The purpose of this investigation was to quantify the cardiovascular, respiratory, and cerebrovascular effects of two common yogic breathing exercises (YBE): bhastrika and chaturbhuj; and to determine the effect of their consistent practice on chemosensitivity. The first study was cross-sectional and compared experienced yogic breathers (YB) with matched controls; whereas the second was a 10-week longitudinal training study. The results support four major findings. First chaturbhuj resulted in a hypoxic stimulus in experienced YB compared to control [end-tidal oxygen tension (P ET O 2 ), YB: 77.5±5.7mmHg, P<0.05; control: 94.3±12.0mmHg]. Second, performance of chaturbhuj resulted in cyclic oscillations of mean arterial pressure (MAP), heart rate (HR), and middle cerebral artery velocity (MCAv) consistent with the phases of respiration. Third, post training, performance of bhastrika reduced P ET O 2 (end breath-hold: 90.8 8±12.1mmHg) compared to rest (100.1±7.4, P<0.05); it also resulted in significantly increased MAP at end breath-hold (96.7±13.0mmHg) compared to rest (83.0±6.6mmHg, P<0.05) and significantly increased mean MCAv (end breath-hold: 87.4±23.0cm/s, P<0.05; rest: 55.8±26.3cm/s). Fourth, experienced YB had lower central chemosensitivity than controls (YB: 3.4±0.4; control: 4.6±1.2L/min/mmHg; P<0.05). In conclusion, YBE significantly alter end-tidal gases, resulting in complex oscillations of cardiovascular and cerebrovascular variables, and if practiced consistently, may reduce chemosensitivity. Copyright © 2016. Published by Elsevier B.V.

  15. Comparison of the analytical capabilities of the BAC Datamaster and Datamaster DMT forensic breath testing devices.

    PubMed

    Glinn, Michele; Adatsi, Felix; Curtis, Perry

    2011-11-01

    The State of Michigan uses the Datamaster as an evidential breath testing device. The newest version, the DMT, will replace current instruments in the field as they are retired from service. The Michigan State Police conducted comparison studies to test the analytical properties of the new instrument and to evaluate its response to conditions commonly cited in court defenses. The effects of mouth alcohol, objects in the mouth, and radiofrequency interference on paired samples from drinking subjects were assessed on the DMT. The effects of sample duration and chemical interferents were assessed on both instruments, using drinking subjects and wet-bath simulators, respectively. Our testing shows that Datamaster and DMT results are essentially identical; the DMT gave accurate readings as compared with measurements made using simulators containing standard ethanol solutions and that the DMT did not give falsely elevated breath alcohol results from any of the influences tested. © 2011 American Academy of Forensic Sciences.

  16. β-Cell secretory defects are present in pancreatic insufficient cystic fibrosis with 1-hour oral glucose tolerance test glucose ≥155 mg/dL.

    PubMed

    Nyirjesy, Sarah C; Sheikh, Saba; Hadjiliadis, Denis; De Leon, Diva D; Peleckis, Amy J; Eiel, Jack N; Kubrak, Christina; Stefanovski, Darko; Rubenstein, Ronald C; Rickels, Michael R; Kelly, Andrea

    2018-06-08

    Patients with pancreatic insufficient cystic fibrosis (PI-CF) meeting standard criteria for normal glucose tolerance display impaired β-cell secretory capacity and early-phase insulin secretion defects. We sought evidence of impaired β-cell secretory capacity, a measure of functional β-cell mass, among those with early glucose intolerance (EGI), defined as 1-hour oral glucose tolerance test (OGTT) glucose ≥155 mg/dL (8.6 mmol/L). A cross-sectional study was conducted in the Penn and CHOP Clinical & Translational Research Centers. PI-CF categorized by OGTT as normal (PI-NGT: 1-hour glucose <155 mg/dL and 2-hour <140 mg/dL [7.8 mmol/L]; n = 13), PI-EGI (1-hour ≥155 mg/dL and 2-hour <140 mg/dL; n = 13), impaired (PI-IGT: 2-hour ≥140 and <200 mg/dL [11.1 mmol/L]; n = 8), and diabetic (cystic fibrosis-related diabetes, CFRD: 2-hour ≥200 mg/dL; n = 8) participated. Post-prandial glucose tolerance and insulin secretion, and β-cell secretory capacity and demand were derived from mixed-meal tolerance tests (MMTTs), and glucose-potentiated arginine (GPA) tests, respectively. PI-EGI had elevated post-prandial glucose with reduced early-phase insulin secretion during MMTT compared to PI-NGT (P < .05). PI-EGI also exhibited impaired acute insulin and C-peptide responses to GPA (P < .01 vs PI-NGT), measures of β-cell secretory capacity. Proinsulin secretory ratios were higher under hyperglycemic clamp conditions in PI-IGT and CFRD (P < .05 vs PI-NGT), and correlated with 1-hour glucose in PI-CF (P < .01). PI-CF patients with 1-hour OGTT glucose ≥155 mg/dL already manifest impaired β-cell secretory capacity with associated early-phase insulin secretion defects. Avoiding hyperglycemia in patients with EGI may be important for preventing excessive insulin demand indicated by disproportionately increased proinsulin secretion. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. L(sub 1) Adaptive Control Design for NASA AirSTAR Flight Test Vehicle

    NASA Technical Reports Server (NTRS)

    Gregory, Irene M.; Cao, Chengyu; Hovakimyan, Naira; Zou, Xiaotian

    2009-01-01

    In this paper we present a new L(sub 1) adaptive control architecture that directly compensates for matched as well as unmatched system uncertainty. To evaluate the L(sub 1) adaptive controller, we take advantage of the flexible research environment with rapid prototyping and testing of control laws in the Airborne Subscale Transport Aircraft Research system at the NASA Langley Research Center. We apply the L(sub 1) adaptive control laws to the subscale turbine powered Generic Transport Model. The presented results are from a full nonlinear simulation of the Generic Transport Model and some preliminary pilot evaluations of the L(sub 1) adaptive control law.

  18. Breath carbon stable isotope ratios identify changes in energy balance and substrate utilization in humans

    USDA-ARS?s Scientific Manuscript database

    Rapid detection of shifts in substrate utilization and energy balance would provide a compelling biofeedback tool to enable individuals to lose weight. In a pilot study, we tested whether the natural abundance of exhaled carbon stable isotope ratios (breath d13C values) reflects shifts between negat...

  19. Does smoking abstinence influence distress tolerance? An experimental study comparing the response to a breath-holding test of smokers under tobacco withdrawal and under nicotine replacement therapy.

    PubMed

    Cosci, Fiammetta; Anna Aldi, Giulia; Nardi, Antonio Egidio

    2015-09-30

    Distress tolerance has been operationalized as task persistence in stressful behavioral laboratory tasks. According to the distress tolerance perspective, how an individual responds to discomfort/distress predicts early smoking lapses. This theory seems weakly supported by experimental studies since they are limited in number, show inconsistent results, do not include control conditions. We tested the response to a stressful task in smokers under abstinence and under no abstinence to verify if tobacco abstinence reduces task persistence, thus distress tolerance. A placebo-controlled, double-blind, randomized, cross-over design was used. Twenty smokers underwent a breath holding test after the administration of nicotine on one test day and a placebo on another test day. Physiological and psychological variables were assessed at baseline and directly before and after each challenge. Abstinence induced a statistically significant shorter breath holding duration relative to the nicotine condition. No different response to the breath holding test was observed when nicotine and placebo conditions were compared. No response to the breath holding test was found when pre- and post-test values of heart rate, blood pressure, Visual Analogue Scale for fear or discomfort were compared. In brief, tobacco abstinence reduces breath holding duration but breath holding test does not influence discomfort. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. Humidification performance of humidifying devices for tracheostomized patients with spontaneous breathing: a bench study.

    PubMed

    Chikata, Yusuke; Oto, Jun; Onodera, Mutsuo; Nishimura, Masaji

    2013-09-01

    Heat and moisture exchangers (HMEs) are commonly used for humidifying respiratory gases administered to mechanically ventilated patients. While they are also applied to tracheostomized patients with spontaneous breathing, their performance in this role has not yet been clarified. We carried out a bench study to investigate the effects of spontaneous breathing parameters and oxygen flow on the humidification performance of 11 HMEs. We evaluated the humidification provided by 11 HMEs for tracheostomized patients, and also by a system delivering high-flow CPAP, and an oxygen mask with nebulizer heater. Spontaneous breathing was simulated with a mechanical ventilator, lung model, and servo-controlled heated humidifier at tidal volumes of 300, 500, and 700 mL, and breathing frequencies of 10 and 20 breaths/min. Expired gas was warmed to 37°C. The high-flow CPAP system was set to deliver 15, 30, and 45 L/min. With the 8 HMEs that were equipped with ports to deliver oxygen, and with the high-flow CPAP system, measurements were taken when delivering 0 and 3 L/min of dry oxygen. After stabilization we measured the absolute humidity (AH) of inspired gas with a hygrometer. AH differed among HMEs applied to tracheostomized patients with spontaneous breathing. For all the HMEs, as tidal volume increased, AH decreased. At 20 breaths/min, AH was higher than at 10 breaths/min. For all the HMEs, when oxygen was delivered, AH decreased to below 30 mg/L. With an oxygen mask and high-flow CPAP, at all settings, AH exceeded 30 mg/L. None of the HMEs provided adequate humidification when supplemental oxygen was added. In the ICU, caution is required when applying HME to tracheostomized patients with spontaneous breathing, especially when supplemental oxygen is required.

  1. A nanomaterial-based breath test for distinguishing gastric cancer from benign gastric conditions.

    PubMed

    Xu, Z-q; Broza, Y Y; Ionsecu, R; Tisch, U; Ding, L; Liu, H; Song, Q; Pan, Y-y; Xiong, F-x; Gu, K-s; Sun, G-p; Chen, Z-d; Leja, M; Haick, H

    2013-03-05

    Upper digestive endoscopy with biopsy and histopathological evaluation of the biopsy material is the standard method for diagnosing gastric cancer (GC). However, this procedure may not be widely available for screening in the developing world, whereas in developed countries endoscopy is frequently used without major clinical gain. There is a high demand for a simple and non-invasive test for selecting the individuals at increased risk that should undergo the endoscopic examination. Here, we studied the feasibility of a nanomaterial-based breath test for identifying GC among patients with gastric complaints. Alveolar exhaled breath samples from 130 patients with gastric complaints (37 GC/32 ulcers / 61 less severe conditions) that underwent endoscopy/biopsy were analyzed using nanomaterial-based sensors. Predictive models were built employing discriminant factor analysis (DFA) pattern recognition, and their stability against possible confounding factors (alcohol/tobacco consumption; Helicobacter pylori) was tested. Classification success was determined (i) using leave-one-out cross-validation and (ii) by randomly blinding 25% of the samples as a validation set. Complementary chemical analysis of the breath samples was performed using gas chromatography coupled with mass spectrometry. Three DFA models were developed that achieved excellent discrimination between the subpopulations: (i) GC vs benign gastric conditions, among all the patients (89% sensitivity; 90% specificity); (ii) early stage GC (I and II) vs late stage (III and IV), among GC patients (89% sensitivity; 94% specificity); and (iii) ulcer vs less severe, among benign conditions (84% sensitivity; 87% specificity). The models were insensitive against the tested confounding factors. Chemical analysis found that five volatile organic compounds (2-propenenitrile, 2-butoxy-ethanol, furfural, 6-methyl-5-hepten-2-one and isoprene) were significantly elevated in patients with GC and/or peptic ulcer, as compared

  2. 32 CFR 634.37 - Voluntary breath and bodily fluid testing based on implied consent.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) DEPARTMENT OF THE ARMY (CONTINUED) LAW ENFORCEMENT AND CRIMINAL INVESTIGATIONS MOTOR VEHICLE TRAFFIC SUPERVISION Traffic Supervision § 634.37 Voluntary breath and bodily fluid testing based on implied consent... the person was driving under the influence of alcohol or drugs. (3) A request was made to the person...

  3. 32 CFR 634.37 - Voluntary breath and bodily fluid testing based on implied consent.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) DEPARTMENT OF THE ARMY (CONTINUED) LAW ENFORCEMENT AND CRIMINAL INVESTIGATIONS MOTOR VEHICLE TRAFFIC SUPERVISION Traffic Supervision § 634.37 Voluntary breath and bodily fluid testing based on implied consent... the person was driving under the influence of alcohol or drugs. (3) A request was made to the person...

  4. Quantification of the thorax-to-abdomen breathing ratio for breathing motion modeling.

    PubMed

    White, Benjamin M; Zhao, Tianyu; Lamb, James; Bradley, Jeffrey D; Low, Daniel A

    2013-06-01

    The purpose of this study was to develop a methodology to quantitatively measure the thorax-to-abdomen breathing ratio from a 4DCT dataset for breathing motion modeling and breathing motion studies. The thorax-to-abdomen breathing ratio was quantified by measuring the rate of cross-sectional volume increase throughout the thorax and abdomen as a function of tidal volume. Twenty-six 16-slice 4DCT patient datasets were acquired during quiet respiration using a protocol that acquired 25 ciné scans at each couch position. Fifteen datasets included data from the neck through the pelvis. Tidal volume, measured using a spirometer and abdominal pneumatic bellows, was used as breathing-cycle surrogates. The cross-sectional volume encompassed by the skin contour when compared for each CT slice against the tidal volume exhibited a nearly linear relationship. A robust iteratively reweighted least squares regression analysis was used to determine η(i), defined as the amount of cross-sectional volume expansion at each slice i per unit tidal volume. The sum Ση(i) throughout all slices was predicted to be the ratio of the geometric expansion of the lung and the tidal volume; 1.11. The Xiphoid process was selected as the boundary between the thorax and abdomen. The Xiphoid process slice was identified in a scan acquired at mid-inhalation. The imaging protocol had not originally been designed for purposes of measuring the thorax-to-abdomen breathing ratio so the scans did not extend to the anatomy with η(i) = 0. Extrapolation of η(i)-η(i) = 0 was used to include the entire breathing volume. The thorax and abdomen regions were individually analyzed to determine the thorax-to-abdomen breathing ratios. There were 11 image datasets that had been scanned only through the thorax. For these cases, the abdomen breathing component was equal to 1.11 - Ση(i) where the sum was taken throughout the thorax. The average Ση(i) for thorax and abdomen image datasets was found to be 1.20

  5. Optimising diffusion-weighted MR imaging for demonstrating pancreatic cancer: a comparison of respiratory-triggered, free-breathing and breath-hold techniques.

    PubMed

    Kartalis, Nikolaos; Loizou, Louiza; Edsborg, Nick; Segersvärd, Ralf; Albiin, Nils

    2012-10-01

    To compare respiratory-triggered, free-breathing, and breath-hold DWI techniques regarding (1) image quality, and (2) signal intensity (SI) and ADC measurements in pancreatic ductal adenocarcinoma (PDAC). Fifteen patients with histopathologically proven PDAC underwent DWI prospectively at 1.5 T (b = 0, 50, 300, 600 and 1,000 s/mm(2)) with the three techniques. Two radiologists, independently and blindly, assigned total image quality scores [sum of rating diffusion images (lesion detection, anatomy, presence of artefacts) and ADC maps (lesion characterisation, overall image quality)] per technique and ranked them. The lesion SI, signal-to-noise ratio, mean ADC and coefficient of variation (CV) were compared. Total image quality scores for respiratory-triggered, free-breathing and breath-hold techniques were 17.9, 16.5 and 17.1 respectively (respiratory-triggered was significantly higher than free-breathing but not breath-hold). The respiratory-triggered technique had a significantly higher ranking. Lesion SI on all b-values and signal-to-noise ratio on b300 and b600 were significantly higher for the respiratory-triggered technique. For respiratory-triggered, free-breathing and breath-hold techniques the mean ADCs were 1.201, 1.132 and 1.253 × 10(-3) mm(2)/s, and mean CVs were 8.9, 10.8 and 14.1 % respectively (respiratory-triggered and free-breathing techniques had a significantly lower mean CV than the breath-hold technique). In both analyses, respiratory-triggered DWI showed superiority and seems the optimal DWI technique for demonstrating PDAC. • Diffusion-weighted magnetic resonance imaging is increasingly used to detect pancreatic cancer • Images are acquired using various breathing techniques and multiple b-values • Breathing techniques used: respiratory-triggering, free-breathing and breath-hold • Respiratory-triggering seems the optimal breathing technique for demonstrating pancreatic cancer.

  6. Theoretical X-ray production cross sections at incident photon energies across L{sub i} (i=1-3) absorption edges of Br

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Puri, Sanjiv

    The X-ray production (XRP) cross sections, σ{sub Lk} (k = l, η, α, β{sub 6}, β{sub 1}, β{sub 3}, β{sub 4}, β{sub 9,10}, γ{sub 1,5}, γ{sub 2,3}) have been evaluated at incident photon energies across the L{sub i}(i=1-3) absorption edge energies of {sub 35}Br using theoretical data sets of different physical parameters, namely, the L{sub i}(i=1-3) sub-shell the X-ray emission rates based on the Dirac-Fock (DF) model, the fluorescence and Coster Kronig yields based on the Dirac-Hartree-Slater (DHS) model, and two sets of the photoionisation cross sections based on the relativistic Hartree-Fock-Slater (RHFS) model and the Dirac-Fock (DF) model, inmore » order to highlight the importance of electron exchange effects at photon energies in vicinity of absorption edge energies.« less

  7. Improved Pharmacokinetics of Sumatriptan With Breath Powered™ Nasal Delivery of Sumatriptan Powder

    PubMed Central

    Obaidi, Mohammad; Offman, Elliot; Messina, John; Carothers, Jennifer; Djupesland, Per G; Mahmoud, Ramy A

    2013-01-01

    Objectives.— The purpose of this study was to directly compare the pharmacokinetic (PK) profile of 22-mg sumatriptan powder delivered intranasally with a novel Breath Powered™ device (11 mg in each nostril) vs a 20-mg sumatriptan liquid nasal spray, a 100-mg oral tablet, and a 6-mg subcutaneous injection. Background.— A prior PK study found that low doses of sumatriptan powder delivered intranasally with a Breath Powered device were efficiently and rapidly absorbed. An early phase clinical trial with the same device and doses found excellent tolerability with high response rates and rapid onset of pain relief, approaching the benefits of injection despite significantly lower predicted drug levels. Methods.— An open-label, cross-over, comparative bioavailability study was conducted in 20 healthy subjects at a single center in the USA. Following randomization, fasted subjects received a single dose of each of the 4 treatments separated by a 7-day washout. Blood samples were taken pre-dose and serially over 14 hours post-dose for PK analysis. Results.— Quantitative measurement of residuals in used Breath Powered devices demonstrated that the devices delivered 8 ± 0.9 mg (mean ± standard deviation) of sumatriptan powder in each nostril (total dose 16 mg). Although the extent of systemic exposure over 14 hours was similar following Breath Powered delivery of 16-mg sumatriptan powder and 20-mg liquid nasal spray (area under the curve [AUC]0-∞ 64.9 ng*hour/mL vs 61.1 ng*hour/mL), sumatriptan powder, despite a 20% lower dose, produced 27% higher peak exposure (Cmax 20.8 ng/mL vs 16.4 ng/mL) and 61% higher exposure in the first 30 minutes compared with the nasal spray (AUC0-30 minutes 5.8 ng*hour/mL vs 3.6 ng*hour/mL). The magnitude of difference is larger on a per-milligram basis. The absorption profile following standard nasal spray demonstrated bimodal peaks, consistent with lower early followed by higher later absorptions. In

  8. Methionine kinetics in adult men: effects of dietary betaine on L-(2H3-methyl-1-13C)methionine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Storch, K.J.; Wagner, D.A.; Young, V.R.

    1991-08-01

    The effects of a daily 3-g supplement of betaine on kinetic aspects of L-(2H3-methyl-1-13C)methionine (MET) metabolism in healthy young adult men were explored. Four groups of four subjects each were given a control diet, based on an L-amino acid mixture supplying 29.5 and 21.9 mg.kg-1.d-1 of L-methionine and L-cystine for 4 d before the tracer study, conducted on day 5 during the fed state. Two groups received the control diet and two groups received the betaine supplement. Tracer was given intravenously (iv) or orally. The transmethylation rate of MET (TM), homocysteine remethylation (RM), and oxidation of methionine were estimated frommore » plasma methionine labeling and 13C enrichment of expired air. RM tended to increase (P = 0.14) but the TM and methionine oxidation were significantly (P less than 0.05) higher after betaine supplementation when estimated with the oral tracer. No differences were detected with the intravenous tracer. Methionine concentration in plasma obtained from blood taken from subjects in the fed state was higher (P less than 0.01) with betaine supplementation. These results suggest that excess methyl-group intake may increase the dietary requirement for methionine.« less

  9. Ventilatory inhomogeneity determined from multiple-breath washouts during sustained microgravity on Spacelab SLS-1.

    PubMed

    Prisk, G K; Guy, H J; Elliott, A R; Paiva, M; West, J B

    1995-02-01

    We used multiple-breath N2 washouts (MBNW) to study the inhomogeneity of ventilation in four normal humans (mean age 42.5 yr) before, during, and after 9 days of exposure to microgravity on Spacelab Life Sciences-1. Subjects performed 20-breath MBNW at tidal volumes of approximately 700 ml and 12-breath MBNW at tidal volumes of approximately 1,250 ml. Six indexes of ventilatory inhomogeneity were derived from data from 1) distribution of specific ventilation (SV) from mixed-expired and 2) end-tidal N2, 3) change of slope of N2 washout (semilog plot) with time, 4) change of slope of normalized phase III of successive breaths, 5) anatomic dead space, and 6) Bohr dead space. Significant ventilatory inhomogeneity was seen in the standing position at normal gravity (1 G). When we compared standing 1 G with microgravity, the distributions of SV became slightly narrower, but the difference was not significant. Also, there were no significant changes in the change of slope of the N2 washout, change of normalized phase III slopes, or the anatomic and Bohr dead spaces. By contrast, transition from the standing to supine position in 1 G resulted in significantly broader distributions of SV (P < 0.05) and significantly greater changes in the changes in slope of the N2 washouts (P < 0.001), indicating more ventilatory inhomogeneity in that posture. Thus these techniques can detect relatively small changes in ventilatory inhomogeneity. We conclude that the primary determinants of ventilatory inhomogeneity during tidal breathing in the upright posture are not gravitational in origin.

  10. Ventilatory inhomogeneity determined from multiple-breath washouts during sustained microgravity on Spacelab SLS-1

    NASA Technical Reports Server (NTRS)

    Prisk, G. Kim; Guy, Harold J. B.; Elliott, Ann R.; Paiva, Manuel; West, John B.

    1995-01-01

    We used multiple-breath N2 washouts (MBNW) to study the homogeneity of ventilation in four normal humans (mean age 42.5 yr) before, during, and after 9 days of exposure to microgravity on Spacelab Life Sciences-1. Subjects performed 20-breath MBNW at tidal volumes of approximately 700 ml and 12-breath MBNW at tidal volumes of approximately 1,250 ml. Six indexes of ventilatory inhomogeneity were derived from data from (1) distribution of specific ventilation (SV) from mixed-expired and (2) end-tidal N2, (3) change of slope of N2 washout (semilog plot) with time, (4) change of slope of normalized phase III of successive breaths, (5) anatomic lead dead space, and (6) Bohr dead space. Significant ventilatory inhomogeneity was seen in the standing position at normal gravity (1 G). When we compared standing 1 G with microgravity, the distributions of SV became slightly narrower, but the difference was not significant. Also, there were no significant changes in the change of slope of the N2 washout, change of normalized phase III slopes, or the anatomic and Bohr dead spaces. By contrast, transition from the standing to supine position in 1 G resulted in significantly broader distributions of SV and significantly greater changes in the changes in slope of the N2 washouts, indicating more ventilatory inhomogeneity in that posture. Thus these techniques can detect relatively small changes in ventilatory inhomogeneity. We conclude that the primary determinants of ventilatory inhomogeneity during tidal breathing in the upright posture are not gravitational in origin.

  11. Sensing the effects of mouth breathing by using 3-tesla MRI

    NASA Astrophysics Data System (ADS)

    Park, Chan-A.; Kang, Chang-Ki

    2017-06-01

    We investigated the effects of mouth breathing and typical nasal breathing on brain function by using blood-oxygenation-level-dependent (BOLD) functional magnetic resonance imaging (fMRI). The study had two parts: the first test was a simple contrast between mouth and nasal breathing, and the second test involved combined breathing modes, e.g., mouth inspiration and nasal expiration. Eleven healthy participants performed the combined breathing task while undergoing 3T fMRI. In the group-level analysis, contrast images acquired by using an individual participantlevel analysis were processed using the one-sample t test. We also conducted a region-of-interest analysis comparing signal intensity changes between the breathing modes; the region was selected using an automated anatomical labeling map. The results demonstrated that the BOLD signal in the hippocampus and brainstem was significantly decreased in mouth breathing relative to nasal breathing. On the other hand, both the precentral and postcentral gyri showed activation that was more significant in mouth breathing compared to nasal breathing. This study suggests that the BOLD activity patterns between mouth and nasal breathing may be induced differently, especially in the hippocampus, which could provide clues to explain the effects on brain cognitive function due to mouth breathing.

  12. Serotonin receptor 1A–modulated phosphorylation of glycine receptor α3 controls breathing in mice

    PubMed Central

    Manzke, Till; Niebert, Marcus; Koch, Uwe R.; Caley, Alex; Vogelgesang, Steffen; Hülsmann, Swen; Ponimaskin, Evgeni; Müller, Ulrike; Smart, Trevor G.; Harvey, Robert J.; Richter, Diethelm W.

    2010-01-01

    Rhythmic breathing movements originate from a dispersed neuronal network in the medulla and pons. Here, we demonstrate that rhythmic activity of this respiratory network is affected by the phosphorylation status of the inhibitory glycine receptor α3 subtype (GlyRα3), which controls glutamatergic and glycinergic neuronal discharges, subject to serotonergic modulation. Serotonin receptor type 1A–specific (5-HTR1A–specific) modulation directly induced dephosphorylation of GlyRα3 receptors, which augmented inhibitory glycine-activated chloride currents in HEK293 cells coexpressing 5-HTR1A and GlyRα3. The 5-HTR1A–GlyRα3 signaling pathway was distinct from opioid receptor signaling and efficiently counteracted opioid-induced depression of breathing and consequential apnea in mice. Paradoxically, this rescue of breathing originated from enhanced glycinergic synaptic inhibition of glutamatergic and glycinergic neurons and caused disinhibition of their target neurons. Together, these effects changed respiratory phase alternations and ensured rhythmic breathing in vivo. GlyRα3-deficient mice had an irregular respiratory rhythm under baseline conditions, and systemic 5-HTR1A activation failed to remedy opioid-induced respiratory depression in these mice. Delineation of this 5-HTR1A–GlyRα3 signaling pathway offers a mechanistic basis for pharmacological treatment of opioid-induced apnea and other breathing disturbances caused by disorders of inhibitory synaptic transmission, such as hyperekplexia, hypoxia/ischemia, and brainstem infarction. PMID:20978350

  13. Breath alcohol concentration determined with a new analyzer using free exhalation predicts almost precisely the arterial blood alcohol concentration.

    PubMed

    Lindberg, L; Brauer, S; Wollmer, P; Goldberg, L; Jones, A W; Olsson, S G

    2007-05-24

    A new breath alcohol (ethanol) analyzer has been developed, which allows free exhalation, standardizes measured exhaled alcohol concentration to fully saturated water vapor at a body temperature of 37 degrees C (43.95 mg/L) and includes a built-in self-calibration system. We evaluated the performance of this instrument by comparing standardized alcohol concentration in freely expired breath (BrAC) with arterial (ABAC) and venous (VBAC) blood alcohol concentrations in fifteen healthy volunteers who drank 0.6 g of alcohol per kg body weight. The precision (coefficient of variation, CV) of the analyzer based on in vivo duplicate measurements in all phases of the alcohol metabolism was 1.7%. The ABAC/BrAC ratio was 2251+/-46 (mean+/-S.D.) in the post-absorptive phase and the mean bias between ABAC and BrAC x 2251 was 0.0035 g/L with 95% limits of agreement of 0.033 and -0.026. The ABAC and BrAC x 2251 were highly correlated (r=0.998, p<0.001) and the regression relationship was ABAC = 0.00045 + 1.0069 x (BrAC x 2251) indicating excellent agreement and no fixed or proportional bias. In the absorption phase, ABAC exceeded BrAC x 2251 by at most 0.04+/-0.03 g/L when tests were made at 10 min post-dosing (p<0.05). The VBAC/BrAC ratio never stabilized and varied continuously between 1834 and 3259. There was a proportional bias between VBAC and BrAC x 2251 (ABAC) in the post-absorptive phase (p<0.001). The pharmacokinetic analysis of the elimination rates of alcohol and times to zero BAC confirmed that BrAC x 2251 and ABAC agreed very well with each other, but not with VBAC (p<0.001). We conclude that this new breath analyzer using free exhalation has a high precision for in vivo testing. The BrAC reflects very accurately ABAC in the post-absorption phase and substantially well in the absorption phase and thereby reflects the concentration of alcohol reaching the brain. Our findings highlight the magnitude of arterio-venous differences in alcohol concentration and support

  14. Random breath testing in Australia: getting it to work according to specifications.

    PubMed

    Homel, R

    1993-01-01

    After reading the deterrence literature, particularly the work of H. Laurence Ross, I concluded in the late 1970's that many road accidents could be prevented through the wholehearted implementation of random breath testing (RBT). RBT is a system of drink-drive law enforcement which aims to increase the perceived likelihood of apprehension through the use of mass breath testing techniques at roadblocks which are highly visible, are unpredictable in their locations and give the impression of ubiquity. As the result of public pressure, RBT was introduced in NSW in December 1982, with spectacular results. The law was intensively enforced and extensively advertised, partly due to the advocacy of researchers such as myself, but also because ther was an acute political need for instant results. Since RBT is a difficult enforcement technique for police to sustain in effective form, researchers must strive to improve their understanding of what works, and remain in close contact with police, policy makers and politicians. Although this process is costly in terms of time and, possibly, academic 'pay-off', it is essential if the fragile understanding of deterrence principles amongst these groups is not to lead to superficially attractive, but probably ineffective techniques such as low visibility mobile RBT.

  15. Breathing efficiency during inspiratory threshold loading in patients with chronic obstructive pulmonary disease.

    PubMed

    Baarends, E M; Schols, A M; Nusmeier, C M; van der Grinten, C P; Wouters, E F

    1998-05-01

    Patients with chronic obstructive pulmonary disease (COPD) demonstrate an increased oxygen cost of breathing. It is as yet unclear whether this is related to a decreased breathing efficiency. The aim of the present study was to compare breathing efficiency in 16 patients with COPD (11 men, five women) and 16 healthy elderly subjects (seven men, nine women), and to investigate a possible relationship between breathing efficiency and resting energy expenditure (REE). REE was measured using a ventilated hood system. Breathing efficiency was assessed by measuring oxygen consumption (V'O2), mean inspiratory mouth pressure (MIP) and flow during breathing at rest and subsequently during breathing against an inspiratory threshold (40% of maximal inspiratory pressure). During loaded breathing there was a significant increase in V'O2, MIP, and external work of breathing compared with unloaded breathing in both groups. As intended, ventilation did not increase significantly during the breathing efficiency test in the patients with COPD. The breathing efficiency (median, range) of the patients with COPD was similar (3.7%, 1.4-8.7%) to that of the healthy elderly subjects (3.2%, 1.7-8.3%). Breathing efficiency was not correlated with REE in either group. In the present study, in which dynamic hyperinflation was probably prevented, no difference in breathing efficiency was found between healthy elderly subjects and COPD patients when breathing against an external inspiratory threshold. Furthermore, breathing efficiency was not related to REE in both groups.

  16. Effects of breathing exercises on breathing patterns in obese and non-obese subjects.

    PubMed

    Olsén, M F; Lönroth, H; Bake, B

    1999-05-01

    Chest physiotherapy in connection with abdominal surgery includes different deep-breathing exercises to prevent post-operative pulmonary complications. The therapy is effective in preventing pulmonary complications, especially in high-risk patients such as obese persons. The mechanisms behind the effect is unclear, but part of the effect may be explained by the changes in breathing patterns. The aim of this study was therefore to describe and to analyse the breathing patterns in obese and non-obese subjects during three different breathing techniques frequently used in the treatment of post-operative patients. Twenty-one severely obese [body mass index (BMI) > 40] and 21 non-obese (BMI 19-25) subjects were studied. All persons denied having any lung disease and were non-smokers. The breathing techniques investigated were: deep breaths without any resistance (DB), positive expiratory pressure (PEP) with an airway resistance of approximately +15 cmH2O (1.5 kPa) during expiration, inspiratory resistance positive expiratory pressure (IR-PEP) with a pressure of approximately -10 cmH2O (-1.0 kPa) during inspiration. Expiratory resistance as for PEP. Volume against time was monitored while the subjects were sitting in a body plethysmograph. Variables for volume and flow during the breathing cycle were determined. Tidal volume and alveolar ventilation were highest during DB, and peak inspiratory volume was significantly higher than during PEP and IR-PEP in the group of obese subjects. The breathing cycles were prolonged in all techniques but were most prolonged in PEP and IR-PEP. The functional residual capacity (FRC) was significantly lower during DB than during PEP and IR-PEP in the group of obese subjects. FRC as determined within 2 min of finishing each breathing technique was identical to before the breathing manoeuvres.

  17. Breath measurement instrumentation as alcohol safety interlock systems

    DOT National Transportation Integrated Search

    1974-09-01

    This report describes the results of field tests of in-car instruments which measure alcohol on the driver's breath and prevent him from operating his vehicle if intoxicated. Two types of breath alcohol sensors were used for these tests; a fuel-cell ...

  18. Breathing pattern and breathlessness in idiopathic pulmonary fibrosis: An observational study.

    PubMed

    Olukogbon, Kasope L; Thomas, Paul; Colasanti, Ricardo; Hope-Gill, Ben; Williams, Edgar Mark

    2016-02-01

    Idiopathic pulmonary fibrosis (IPF) is characterized by progressive decline in lung function and increasing dyspnoea. The aim of this study was to investigate the relationship among IPF, pulmonary function, resting tidal breathing patterns and level of breathlessness. Thirty-one participants with IPF and 17 matched healthy controls underwent lung function testing, followed by a 2-min period of resting tidal breathing. The IPF cohort was stratified according to disease severity, based on their forced vital capacity and diffusion capacity for carbon monoxide. In comparison to the healthy controls, the IPF cohort showed a higher tidal volume, VT , of 0.22 L (P = 0.026) and a raised minute ventilation in the severest IPF group, while no differences in the timing of inspiration or expiration were observed. In the IPF cohort, the ratio of VT to forced vital capacity was around 15% higher. These changes corresponded with an increase in the self-reported sensation of breathlessness. Those with IPF increased their depth of breathing with worsening disease severity, with IPF-induced changes in pulmonary function and breathlessness associated with an altered tidal breathing pattern. © 2015 Asian Pacific Society of Respirology.

  19. NASA firefighters breathing system program report

    NASA Technical Reports Server (NTRS)

    Wood, W. B.

    1977-01-01

    Because of the rising incidence of respiratory injury to firefighters, local governments expressed the need for improved breathing apparatus. A review of the NASA firefighters breathing system program, including concept definition, design, development, regulatory agency approval, in-house testing, and program conclusion is presented.

  20. A comparison of blood alcohol levels as determined by breath and blood tests taken in actual field operations.

    DOT National Transportation Integrated Search

    1972-01-01

    During its 1972 session, the General Assembly of Virginia enacted Senate Bill 104, which authorizes the breath test, as well as the blood test used previously, as a proper chemical test to determine the alcoholic content of the blood. Any person arre...

  1. A breath test for malignant mesothelioma using an electronic nose.

    PubMed

    Chapman, Eleanor A; Thomas, Paul S; Stone, Emily; Lewis, Craig; Yates, Deborah H

    2012-08-01

    Malignant mesothelioma (MM) is a rare tumour which is difficult to diagnose in its early stages. Earlier detection of MM could potentially improve survival. Exhaled breath sampling of volatile organic compounds (VOCs) using a carbon polymer array (CPA) electronic nose recognises specific breath profiles characteristic of different diseases, and can distinguish between patients with lung cancer and controls. With MM, the potential confounding effect of other asbestos-related diseases (ARDs) needs to be considered. We hypothesised that as CPA electronic nose would distinguish patients with MM, patients with benign ARDs, and controls with high sensitivity and specificity. 20 MM, 18 ARD and 42 control subjects participated in a cross-sectional, case-control study. Breath samples were analysed using the Cyranose 320 (Smiths Detection, Pasadena, CA, USA), using canonical discriminant analysis and principal component reduction. 10 MM subjects created the training set. Smell prints from 10 new MM patients were distinguished from control subjects with an accuracy of 95%. Patients with MM, ARDs and control subjects were correctly identified in 88% of cases. Exhaled breath VOC profiling can accurately distinguish between patients with MM, ARDs and controls using a CPA electronic nose. This could eventually translate into a screening tool for high-risk populations.

  2. Hypersonic propulsion flight tests as essential to air-breathing aerospace plane development

    NASA Astrophysics Data System (ADS)

    Mehta, U.

    Hypersonic air-breathing propulsion utilizing scramjets can fundamentally change transatmospheric acclerators for transportation from low Earth orbits (LEOs). The value and limitations of ground tests, of flight tests, and of computations are presented, and scramjet development requirements are discussed. Near-full-scale hypersonic propulsion flight tests are essential for developing a prototype hypersonic propulsion system and for developing computation-design technology that can be used in designing that system. In order to determine how these objectives should be achieved, some lessons learned from past programs are presented. A conceptual two-stage-to-orbit (TSTO) prototype/experimental aerospace plane is recommended as a means of providing access-to-space and for conducting flight tests. A road map for achieving these objectives is also presented.

  3. Dyspnea on exertion in obese women: association with an increased oxygen cost of breathing.

    PubMed

    Babb, Tony G; Ranasinghe, Kamalini G; Comeau, Laurie A; Semon, Trisha L; Schwartz, Belinda

    2008-07-15

    Although exertional dyspnea in obesity is an important and prolific clinical concern, the underlying mechanism remains unclear. To investigate whether dyspnea on exertion in otherwise healthy obese women was associated with an increase in the oxygen cost of breathing or cardiovascular deconditioning. Obese women with and without dyspnea on exertion participated in two independent experiments (n = 16 and n = 14). All participants underwent pulmonary function testing, hydrostatic weighing, ratings of perceived breathlessness during cycling at 60 W, and determination of the oxygen cost of breathing during eucapnic voluntary hyperpnea at 40 and 60 L/min. Cardiovascular exercise capacity, fat distribution, and respiratory mechanics were determined in 14 women in experiment 2. Data were analyzed between groups by independent t test, and the relationship between the variables was determined by regression analysis. In both experiments, breathlessness during 60 W cycling was markedly increased in over 37% of the obese women (P < 0.01). Age, height, weight, lung function, and %body fat were not different between the groups in either experiment. In contrast, the oxygen cost of breathing was significantly (P < 0.01) and markedly (38-70%) greater in the obese women with dyspnea on exertion. The oxygen cost of breathing was significantly (P < 0.001) correlated with the rating of perceived breathlessness obtained during the 60 W exercise in experiment 1 (r(2) = 0.57) and experiment 2 (r(2) = 0.72). Peak cardiovascular exercise capacity, fat distribution, and respiratory mechanics were not different between groups in experiment 2. Dyspnea on exertion is prevalent in otherwise healthy obese women, which seems to be strongly associated with an increased oxygen cost of breathing. Exercise capacity is not reduced in obese women with dyspnea on exertion.

  4. Polar Desolvation and Position 226 of Pancreatic and Neutrophil Elastases Are Crucial to their Affinity for the Kunitz-Type Inhibitors ShPI-1 and ShPI-1/K13L.

    PubMed

    Hernández González, Jorge Enrique; García-Fernández, Rossana; Valiente, Pedro Alberto

    2015-01-01

    The Kunitz-type protease inhibitor ShPI-1 inhibits human neutrophil elastase (HNE, Ki = 2.35·10-8 M) but does not interact with the porcine pancreatic elastase (PPE); whereas its P1 site variant, ShPI-1/K13L, inhibits both HNE and PPE (Ki = 1.3·10-9 M, and Ki = 1.2·10-8 M, respectively). By employing a combination of molecular modeling tools, e.g., structural alignment, molecular dynamics simulations and Molecular Mechanics Generalized-Born/Poisson-Boltzmann Surface Area free energy calculations, we showed that D226 of HNE plays a critical role in the interaction of this enzyme with ShPI-1 through the formation of a strong salt bridge and hydrogen bonds with K13 at the inhibitor's P1 site, which compensate the unfavorable polar-desolvation penalty of the latter residue. Conversely, T226 of PPE is unable to establish strong interactions with K13, thereby precluding the insertion of K13 side-chain into the S1 subsite of this enzyme. An alternative conformation of K13 site-chain placed at the entrance of the S1 subsite of PPE, similar to that observed in the crystal structure of ShPI-1 in complex with chymotrypsin (PDB: 3T62), is also unfavorable due to the lack of stabilizing pair-wise interactions. In addition, our results suggest that the higher affinity of ShPI-1/K13L for both elastases mainly arises from the lower polar-desolvation penalty of L13 compared to that of K13, and not from stronger pair-wise interactions of the former residue with those of each enzyme. These results provide insights into the PPE and HNE inhibition and may contribute to the design of more potent and/or specific inhibitors toward one of these proteases.

  5. Regulation of L-type CaV1.3 channel activity and insulin secretion by the cGMP-PKG signaling pathway.

    PubMed

    Sandoval, Alejandro; Duran, Paz; Gandini, María A; Andrade, Arturo; Almanza, Angélica; Kaja, Simon; Felix, Ricardo

    2017-09-01

    cGMP is a second messenger widely used in the nervous system and other tissues. One of the major effectors for cGMP is the serine/threonine protein kinase, cGMP-dependent protein kinase (PKG), which catalyzes the phosphorylation of a variety of proteins including ion channels. Previously, it has been shown that the cGMP-PKG signaling pathway inhibits Ca 2+ currents in rat vestibular hair cells and chromaffin cells. This current allegedly flow through voltage-gated Ca V 1.3L-type Ca 2+ channels, and is important for controlling vestibular hair cell sensory function and catecholamine secretion, respectively. Here, we show that native L-type channels in the insulin-secreting RIN-m5F cell line, and recombinant Ca V 1.3 channels heterologously expressed in HEK-293 cells, are regulatory targets of the cGMP-PKG signaling cascade. Our results indicate that the Ca V α 1 ion-conducting subunit of the Ca V 1.3 channels is highly expressed in RIN-m5F cells and that the application of 8-Br-cGMP, a membrane-permeable analogue of cGMP, significantly inhibits Ca 2+ macroscopic currents and impair insulin release stimulated with high K + . In addition, KT-5823, a specific inhibitor of PKG, prevents the current inhibition generated by 8-Br-cGMP in the heterologous expression system. Interestingly, mutating the putative phosphorylation sites to residues resistant to phosphorylation showed that the relevant PKG sites for Ca V 1.3 L-type channel regulation centers on two amino acid residues, Ser793 and Ser860, located in the intracellular loop connecting the II and III repeats of the Ca V α 1 pore-forming subunit of the channel. These findings unveil a novel mechanism for how the cGMP-PKG signaling pathway may regulate Ca V 1.3 channels and contribute to regulate insulin secretion. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Effect of leak and breathing pattern on the accuracy of tidal volume estimation by commercial home ventilators: a bench study.

    PubMed

    Luján, Manel; Sogo, Ana; Pomares, Xavier; Monsó, Eduard; Sales, Bernat; Blanch, Lluís

    2013-05-01

    New home ventilators are able to provide clinicians data of interest through built-in software. Monitoring of tidal volume (VT) is a key point in the assessment of the efficacy of home mechanical ventilation. To assess the reliability of the VT provided by 5 ventilators in a bench test. Five commercial ventilators from 4 different manufacturers were tested in pressure support mode with the help of a breathing simulator under different conditions of mechanical respiratory pattern, inflation pressure, and intentional leakage. Values provided by the built-in software of each ventilator were compared breath to breath with the VT monitored through an external pneumotachograph. Ten breaths for each condition were compared for every tested situation. All tested ventilators underestimated VT (ranges of -21.7 mL to -83.5 mL, which corresponded to -3.6% to -14.7% of the externally measured VT). A direct relationship between leak and underestimation was found in 4 ventilators, with higher underestimations of the VT when the leakage increased, ranging between -2.27% and -5.42% for each 10 L/min increase in the leakage. A ventilator that included an algorithm that computes the pressure loss through the tube as a function of the flow exiting the ventilator had the minimal effect of leaks on the estimation of VT (0.3%). In 3 ventilators the underestimation was also influenced by mechanical pattern (lower underestimation with restrictive, and higher with obstructive). The inclusion of algorithms that calculate the pressure loss as a function of the flow exiting the ventilator in commercial models may increase the reliability of VT estimation.

  7. Immuno-Oncology Biomarkers for Gastric and Gastroesophageal Junction Adenocarcinoma: Why PD-L1 Testing May Not Be Enough.

    PubMed

    Weinberg, Benjamin A; Xiu, Joanne; Hwang, Jimmy J; Shields, Anthony F; Salem, Mohamed E; Marshall, John L

    2018-04-27

    The treatment of patients with advanced gastric and gastroesophageal junction (G/GEJ) adenocarcinomas has been transformed by the U.S. Food and Drug Administration approval of pembrolizumab. Tumor and adjacent tissue must stain positively for the programmed cell death ligand 1 (PD-L1) protein by companion diagnostic testing. However, some patients with PD-L1-negative tumors also benefit from pembrolizumab. High microsatellite instability (MSI) and tumor mutational load (TML) are positive predictive biomarkers for immune checkpoint inhibition (ICI) in other tumors. We sought to identify more patients who could benefit from ICI using alternative PD-L1 thresholds, MSI, and TML. Tumor specimens underwent next-generation sequencing (NGS) and PD-L1 testing using immunohistochemistry. NGS was used to determine TML and MSI. We profiled 581 G/GEJ adenocarcinoma specimens. PD-L1 staining was scored for intensity (0, none; 1+, weak; 2+, moderate; 3+, strong). Using 2+ staining at a 5% threshold, 9.3% of tumors were PD-L1 positive, and using 1+ staining at 1%, 16.2% were PD-L1 positive. 6.9% of tumors had high MSI. High TML (≥17 mutations per megabase) was seen in 6.9%, and medium TML (≥7) was seen in 56.5% of tumors. Thirty (5.2%) PD-L1-negative tumors at the 1+, 1% threshold had high TML or high MSI. Primary tumors had higher rates of high TML (8.8% vs. 3.9%; p  = .0377) and high MSI (8.5% vs. 3.9%; p  = .0471) than metastases. PD-L1 testing alone fails to detect patients who may benefit from ICI. Lower PD-L1 thresholds and TML testing should be considered in future clinical trials. Pembrolizumab is approved by the U.S. Food and Drug Administration for patients with refractory gastric and gastroesophageal cancers if the tumor and adjacent tissue stain positively for the programmed cell death ligand 1 (PD-L1) protein by companion diagnostic testing. Tumor mutational load, microsatellite instability (MSI), and alternative PD-L1 testing thresholds may serve as

  8. Epilepsy and the ketogenic diet: assessment of ketosis in children using breath acetone.

    PubMed

    Musa-Veloso, Kathy; Rarama, Exequiel; Comeau, Felix; Curtis, Rosalind; Cunnane, Stephen

    2002-09-01

    High-fat ketogenic diets increase ketones (acetoacetate, beta-hydroxybutyrate, and acetone) and are used to treat refractory seizures. Although ketosis is an integral aspect of these therapeutic regimens, the direct importance of ketosis to seizure control needs further investigation. An examination of this relationship requires a reliable, minimally invasive measure of ketosis that can be performed frequently. In the present study, we examined the use of breath acetone as a measure of ketosis in children with refractory seizures on a classic ketogenic diet. Results were compared with breath acetone levels in epilepsy and healthy controls. Children on the ketogenic diet had significantly higher fasting breath acetone compared with epilepsy or healthy controls (2530 +/- 600 nmol/L versus 19 +/- 9 nmol/L and 21 +/- 4 nmol/L, respectively; p < 0.05). One hour after consumption of a ketogenic breakfast meal, breath acetone increased significantly in epilepsy and healthy controls (p < 0.05), but not in children on a ketogenic diet. Children who were on the ketogenic diet for longer periods of time had a significantly lower fasting breath acetone (R(2) = 0.55, p = 0.014). In one child on the ketogenic diet, breath acetone was determined hourly over a 9-h period, both by gas chromatography and by a prototype hand-held breath acetone analyzer. Preliminary results using this hand-held breath acetone analyzer are encouraging. Breath acetone may be a useful tool in examining the relationship between ketosis and seizure control and enhancing our understanding of the mechanism of the ketogenic diet.

  9. Exhaled breath analysis for lung cancer

    PubMed Central

    Sutedja, Tom G.; Zimmerman, Paul V.

    2013-01-01

    Early diagnosis of lung cancer results in improved survival compared to diagnosis with more advanced disease. Early disease is not reliably indicated by symptoms. Because investigations such as bronchoscopy and needle biopsy have associated risks and substantial costs, they are not suitable for population screening. Hence new easily applicable tests, which can be used to screen individuals at risk, are required. Biomarker testing in exhaled breath samples is a simple, relatively inexpensive, non-invasive approach. Exhaled breath contains volatile and non-volatile organic compounds produced as end-products of metabolic processes and the composition of such compounds varies between healthy subjects and subjects with lung cancer. Many studies have analysed the patterns of these compounds in exhaled breath. In addition studies have also reported that the exhaled breath condensate (EBC) can reveal gene mutations or DNA abnormalities in patients with lung cancer. This review has summarised the scientific evidence demonstrating that lung cancer has distinct chemical profiles in exhaled breath and characteristic genetic changes in EBC. It is not yet possible to accurately identify individuals with lung cancer in at risk populations by any of these techniques. However, analysis of both volatile organic compounds in exhaled breath and of EBC have great potential to become clinically useful diagnostic and screening tools for early stage lung cancer detection. PMID:24163746

  10. Effects of breathing variation on gating window internal target volume in respiratory gated radiation therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cai Jing; McLawhorn, Robert; Read, Paul W.

    Purpose: To investigate the effects of breathing variation on gating window internal target volume (ITV{sub GW}) in respiratory gated radiation therapy. Method and Materials: Two-dimensional dynamic MRI (dMRI) of lung motion was acquired in ten volunteers and eight lung cancer patients. Resorted dMRI using 4DCT acquisition method (RedCAM) was generated for selected subjects by simulating the image rebinning process. A dynamic software generated phantom (dSGP) was created by moving a solid circle (to mimic the ''tumor'') with dMRI-determined motion trajectories. The gating window internal target area (ITA{sub GW}, 2D counterpart of ITV{sub GW}) was determined from both RedCAM and dSGP/dMRI.more » Its area (A), major axis (L1), minor axis (L2), and similarity (S) were calculated and compared. Results: In the phantom study of 3 cm tumor, measurements of the ITA{sub GW} from dSGP (A=10.0{+-}1.3 cm{sup 2}, L1=3.8{+-}0.4 cm, and L2=3.3{+-}0.1 cm) are significantly (p<0.001) greater than those from RedCAM (A=8.5{+-}0.7 cm{sup 2}, L1=3.5{+-}0.2 cm, and L2=3.1{+-}0.1 cm). Similarly, the differences are significantly greater (p<0.001) for the 1 cm tumor (A=1.9{+-}0.5 cm{sup 2}, L1=1.9{+-}0.4 cm, and L2=1.3{+-}0.1 cm in dSGP; A=1.3{+-}0.1 cm{sup 2}, L1=1.5{+-}0.2 cm, and L2=1.1{+-}0.1 cm in RedCAM). In patient studies, measurements of the ITA{sub GW} from dMRI (A=15.5{+-}8.2 cm{sup 2}, L1=5.0{+-}1.1 cm, and L2=3.8{+-}1.2 cm) are also significantly greater (p<0.05) than those from RedCAM (A=13.2{+-}8.5 cm{sup 2}, L1=4.3{+-}1.4 cm, and L2=3.7{+-}1.2 cm). Similarities were 0.9{+-}0.1, 0.8{+-}0.1, and 0.8{+-}0.1 in the 3 cm tumor phantom, 1 cm tumor phantom, and patient studies, respectively. Conclusion: ITV{sub GW} can be underestimated by 4DCT due to breathing variations. An additional margin may be needed to account for this potential error in generating a PTV{sub GW}. Cautions need to be taken when generating ITV{sub GW} from 4DCT in respiratory gated radiation therapy

  11. Isolation and characterization of novel 1,3-propanediol-producing Lactobacillus panis PM1 from bioethanol thin stillage.

    PubMed

    Khan, Nurul H; Kang, Tae Sun; Grahame, Douglas A S; Haakensen, Monique C; Ratanapariyanuch, Kornsulee; Reaney, Martin J; Korber, Darren R; Tanaka, Takuji

    2013-01-01

    Conversion of glycerol to 1,3-propanediol (1,3-PDO) is an attractive option to increase the economic efficiency of the biofuel industry. A bacterial strain that produced 1,3-PDO in the presence of glycerol was isolated from thin stillage, the fermentation residue of bioethanol production. This 1,3-PDO-producing organism was identified as Lactobacillus panis through biochemical characteristics and by 16S rRNA sequencing. Characterization of the L. panis strain hereafter designated as PM1 revealed it was an aerotolerant acidophilic anaerobe able to grow over a wide range of temperatures; tolerant to high concentrations of sodium chloride, ethanol, acetic acid, and lactic acid; and resistant to many common antibiotics. L. panis PM1 could utilize glucose, lactose, galactose, maltose, xylose, and arabinose, but could not grow on sucrose or fructose. Production of 1,3-PDO by L. panis PM1 occurred only when glucose was available as the carbon source in the absence of oxygen. These metabolic characteristics strongly suggested NADH recycling for glucose metabolism is achieved through 1,3-PDO production by this strain. These characteristics classified L. panis PM1 within the group III heterofermentative lactic acid bacteria, which includes the well-characterized 1,3-PDO-producing strain, Lactobacillus reuteri. Metabolite production profiles showed that L. panis PM1 produced considerable amounts of succinic acid (~11-12 mM) from normal MRS medium, which distinguishes this strain from L. reuteri strains.

  12. L1 and L2 Picture Naming in Mandarin-English Bilinguals: A Test of Bilingual Dual Coding Theory

    ERIC Educational Resources Information Center

    Jared, Debra; Poh, Rebecca Pei Yun; Paivio, Allan

    2013-01-01

    This study examined the nature of bilinguals' conceptual representations and the links from these representations to words in L1 and L2. Specifically, we tested an assumption of the Bilingual Dual Coding Theory that conceptual representations include image representations, and that learning two languages in separate contexts can result in…

  13. Effects of heat and moisture exchangers on minute ventilation, ventilatory drive, and work of breathing during pressure-support ventilation in acute respiratory failure.

    PubMed

    Pelosi, P; Solca, M; Ravagnan, I; Tubiolo, D; Ferrario, L; Gattinoni, L

    1996-07-01

    To evaluate the effect of two commonly used heat and moisture exchangers on respiratory function and gas exchange in patients with acute respiratory failure during pressure-support ventilation. Prospective, randomized trial. Intensive care unit of a university hospital. Fourteen patients with moderate acute respiratory failure, receiving pressure-support ventilation. Patients were assigned randomly to two treatment groups, in which two different heat and moisture exchangers were used: Hygroster (DAR S.p.A., Mirandola, Italy) with higher deadspace and lower resistance (group 1, n = 7), and Hygrobac-S (DAR S.p.A.) with lower deadspace and higher resistance (group 2, n = 7). Patients were assessed at three pressure-support levels: a) baseline (10.3 +/- 2.4 cm H2O for group 1, 9.3 +/- 1.3 cm H2O for group 2); b) 5 cm H2O above baseline; and c) 5 cm H2O below baseline. Measurements obtained with the heat and moisture exchangers were compared with those values obtained using the standard heated hot water humidifier. At baseline pressure-support ventilation, the insertion of both heat and moisture exchangers induced in all patients a significant increase in the following parameters: minute ventilation (12.4 +/- 3.2 to 15.0 +/- 2.6 L/min for group 1, and 11.8 +/- 3.6 to 14.2 +/- 3.5 L/min for group 2); static intrinsic positive end-expiratory pressure (2.9 +/- 2.0 to 5.1 +/- 3.2 cm H2O for group 1, and 2.9 +/- 1.7 to 5.5 +/- 3.0 cm H2O for group 2); ventilatory drive, expressed as P41 (2.7 +/- 2.0 to 5.2 +/- 4.0 cm H2O for group 1, and 3.3 +/- 2.0 to 5.3 +/- 3.0 cm H2O for group 2); and work of breathing, expressed as either power (8.8 +/- 9.4 to 14.5 +/- 10.3 joule/ min for group 1, and 10.5 +/- 7.4 to 16.6 +/- 11.0 joule/min for group 2) or work per liter of ventilation (0.6 +/- 0.6 to 1.0 +/- 0.7 joule/L for group 1, and 0.8 +/- 0.4 to 1.1 +/- 0.5 joule/L. for group 2). These increases also occurred when pressure-support ventilation was both above and below the baseline

  14. Leaching process for recovering valuable metals from the LiNi1/3Co1/3Mn1/3O2 cathode of lithium-ion batteries.

    PubMed

    He, Li-Po; Sun, Shu-Ying; Song, Xing-Fu; Yu, Jian-Guo

    2017-06-01

    In view of the importance of environmental protection and resource recovery, recycling of spent lithium-ion batteries (LIBs) and electrode scraps generated during manufacturing processes is quite necessary. An environmentally sound leaching process for the recovery of Li, Ni, Co, and Mn from spent LiNi 1/3 Co 1/3 Mn 1/3 O 2 -based LIBs and cathode scraps was investigated in this study. Eh-pH diagrams were used to determine suitable leaching conditions. Operating variables affecting the leaching efficiencies for Li, Ni, Co, and Mn from LiNi 1/3 Co 1/3 Mn 1/3 O 2 , such as the H 2 SO 4 concentration, temperature, H 2 O 2 concentration, stirring speed, and pulp density, were investigated to determine the most efficient conditions for leaching. The leaching efficiencies for Li, Ni, Co, and Mn reached 99.7% under the optimized conditions of 1M H 2 SO 4 , 1vol% H 2 O 2 , 400rpm stirring speed, 40g/L pulp density, and 60min leaching time at 40°C. The leaching kinetics of LiNi 1/3 Co 1/3 Mn 1/3 O 2 were found to be significantly faster than those of LiCoO 2 . Based on the variation in the weight fraction of the metal in the residue, the "cubic rate law" was revised as follows: θ(1-f) 1/3 =(1-kt/r 0 ρ), which could characterize the leaching kinetics optimally. The activation energies were determined to be 64.98, 65.16, 66.12, and 66.04kJ/mol for Li, Ni, Co, and Mn, respectively, indicating that the leaching process was controlled by the rate of surface chemical reactions. Finally, a simple process was proposed for the recovery of valuable metals from spent LiNi 1/3 Co 1/3 Mn 1/3 O 2 -based LIBs and cathode scraps. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Effect of Short-Term Acclimatization to High Altitude on Sleep and Nocturnal Breathing

    PubMed Central

    Nussbaumer-Ochsner, Yvonne; Ursprung, Justyna; Siebenmann, Christoph; Maggiorini, Marco; Bloch, Konrad E.

    2012-01-01

    Study Objective: Objective physiologic data on sleep and nocturnal breathing at initial exposure and during acclimatization to high altitude are scant. We tested the hypothesis that acute exposure to high altitude induces quantitative and qualitative changes in sleep and that these changes are partially reversed with acclimatization. Design: Prospective observation. Setting: One night in a sleep laboratory at 490 meters, the first and the third night in a mountain hut at 4559 meters. Participants: Sixteen healthy mountaineers. Intervention: Altitude exposure. Measurements: Polysomnography, questionnaire evaluation of sleep and acute mountain sickness. Results: Compared to 490 m, median nocturnal oxygen saturation decreased during the 1st night at 4559 m from 96% to 67%, minute ventilation increased from 4.4 to 6.3 L/min, and the apnea-hypopnea index increased from 0.1 to 60.9/h; correspondingly, sleep efficiency decreased from 93% to 69%, and slow wave sleep from 18% to 6% (P < 0.05, all instances). During the 3rd night at 4559 m, oxygen saturation was 71%, slow wave sleep 11% (P < 0.05 vs. 1st night, both instances) and the apnea/hypopnea index was 86.5/h (P = NS vs. 1st night). Symptoms of AMS and of disturbed sleep were significantly reduced in the morning after the 3rd vs. the 1st night at 4559 m. Conclusions: In healthy mountaineers ascending rapidly to high altitude, sleep quality is initially impaired but improves with acclimatization in association with improved oxygen saturation, while periodic breathing persists. Therefore, high altitude sleep disturbances seem to be related predominantly to hypoxemia rather than to periodic breathing. Citation: Nussbaumer-Ochsner Y; Ursprung J; Siebenmann C; Maggiorini M; Bloch KE. Effect of short-term acclimatization to high altitude on sleep and nocturnal breathing. SLEEP 2012;35(3):419-423. PMID:22379248

  16. Clinical Feasibility of Free-Breathing Dynamic T1-Weighted Imaging With Gadoxetic Acid-Enhanced Liver Magnetic Resonance Imaging Using a Combination of Variable Density Sampling and Compressed Sensing.

    PubMed

    Yoon, Jeong Hee; Yu, Mi Hye; Chang, Won; Park, Jin-Young; Nickel, Marcel Dominik; Son, Yohan; Kiefer, Berthold; Lee, Jeong Min

    2017-10-01

    The purpose of the study was to investigate the clinical feasibility of free-breathing dynamic T1-weighted imaging (T1WI) using Cartesian sampling, compressed sensing, and iterative reconstruction in gadoxetic acid-enhanced liver magnetic resonance imaging (MRI). This retrospective study was approved by our institutional review board, and the requirement for informed consent was waived. A total of 51 patients at high risk of breath-holding failure underwent dynamic T1WI in a free-breathing manner using volumetric interpolated breath-hold (BH) examination with compressed sensing reconstruction (CS-VIBE) and hard gating. Timing, motion artifacts, and image quality were evaluated by 4 radiologists on a 4-point scale. For patients with low image quality scores (<3) on the late arterial phase, respiratory motion-resolved (extradimension [XD]) reconstruction was additionally performed and reviewed in the same manner. In addition, in 68.6% (35/51) patients who had previously undergone liver MRI, image quality and motion artifacts on dynamic phases using CS-VIBE were compared with previous BH-T1WIs. In all patients, adequate arterial-phase timing was obtained at least once. Overall image quality of free-breathing T1WI was 3.30 ± 0.59 on precontrast and 2.68 ± 0.70, 2.93 ± 0.65, and 3.30 ± 0.49 on early arterial, late arterial, and portal venous phases, respectively. In 13 patients with lower than average image quality (<3) on the late arterial phase, motion-resolved reconstructed T1WI (XD-reconstructed CS-VIBE) significantly reduced motion artifacts (P < 0.002-0.021) and improved image quality (P < 0.0001-0.002). In comparison with previous BH-T1WI, CS-VIBE with hard gating or XD reconstruction showed less motion artifacts and better image quality on precontrast, arterial, and portal venous phases (P < 0.0001-0.013). Volumetric interpolated breath-hold examination with compressed sensing has the potential to provide consistent, motion-corrected free-breathing dynamic T

  17. Evaluation of Transient Motion During Gadoxetic Acid-Enhanced Multiphasic Liver Magnetic Resonance Imaging Using Free-Breathing Golden-Angle Radial Sparse Parallel Magnetic Resonance Imaging.

    PubMed

    Yoon, Jeong Hee; Lee, Jeong Min; Yu, Mi Hye; Hur, Bo Yun; Grimm, Robert; Block, Kai Tobias; Chandarana, Hersh; Kiefer, Berthold; Son, Yohan

    2018-01-01

    The aims of this study were to observe the pattern of transient motion after gadoxetic acid administration including incidence, onset, and duration, and to evaluate the clinical feasibility of free-breathing gadoxetic acid-enhanced liver magnetic resonance imaging using golden-angle radial sparse parallel (GRASP) imaging with respiratory gating. In this institutional review board-approved prospective study, 59 patients who provided informed consents were analyzed. Free-breathing dynamic T1-weighted images (T1WIs) were obtained using GRASP at 3 T after a standard dose of gadoxetic acid (0.025 mmol/kg) administration at a rate of 1 mL/s, and development of transient motion was monitored, which is defined as a distinctive respiratory frequency alteration of the self-gating MR signals. Early arterial, late arterial, and portal venous phases retrospectively reconstructed with and without respiratory gating and with different temporal resolutions (nongated 13.3-second, gated 13.3-second, gated 6-second T1WI) were evaluated for image quality and motion artifacts. Diagnostic performance in detecting focal liver lesions was compared among the 3 data sets. Transient motion (mean duration, 21.5 ± 13.0 seconds) was observed in 40.0% (23/59) of patients, 73.9% (17/23) of which developed within 15 seconds after gadoxetic acid administration. On late arterial phase, motion artifacts were significantly reduced on gated 13.3-second and 6-second T1WI (3.64 ± 0.34, 3.61 ± 0.36, respectively), compared with nongated 13.3-second T1WI (3.12 ± 0.51, P < 0.0001). Overall, image quality was the highest on gated 13.3-second T1WI (3.76 ± 0.39) followed by gated 6-second and nongated 13.3-second T1WI (3.39 ± 0.55, 2.57 ± 0.57, P < 0.0001). Only gated 6-second T1WI showed significantly higher detection performance than nongated 13.3-second T1WI (figure of merit, 0.69 [0.63-0.76]) vs 0.60 [0.56-0.65], P = 0.004). Transient motion developed in 40% (23/59) of patients shortly after

  18. A simple, remote, video based breathing monitor.

    PubMed

    Regev, Nir; Wulich, Dov

    2017-07-01

    Breathing monitors have become the all-important cornerstone of a wide variety of commercial and personal safety applications, ranging from elderly care to baby monitoring. Many such monitors exist in the market, some, with vital signs monitoring capabilities, but none remote. This paper presents a simple, yet efficient, real time method of extracting the subject's breathing sinus rhythm. Points of interest are detected on the subject's body, and the corresponding optical flow is estimated and tracked using the well known Lucas-Kanade algorithm on a frame by frame basis. A generalized likelihood ratio test is then utilized on each of the many interest points to detect which is moving in harmonic fashion. Finally, a spectral estimation algorithm based on Pisarenko harmonic decomposition tracks the harmonic frequency in real time, and a fusion maximum likelihood algorithm optimally estimates the breathing rate using all points considered. The results show a maximal error of 1 BPM between the true breathing rate and the algorithm's calculated rate, based on experiments on two babies and three adults.

  19. 13. Historic American Buildings Survey Allen L. Hubbard, Photographer December ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. Historic American Buildings Survey Allen L. Hubbard, Photographer December 1, 1936 CHEST (North room 3rd floor) (SWISS FURNITURE) - Fort Western, Main Building, Bowman Street, Augusta, Kennebec County, ME

  20. Gravitational independence of single-breath washout tests in recumbent dogs

    NASA Technical Reports Server (NTRS)

    Tomioka, Shinichi; Kubo, Susumu; Guy, Harold J. B.; Prisk, G. K.

    1988-01-01

    The effect of gravitational orientation in the mechanism of lung filling and emptying in dogs was examined by conducting simultaneously Ar-bolus and N2 single-breath washout tests (SBWTs) in 10 anesthetized dogs (prone and supine), with three of the dogs subjected to body rotation. Transpulmonary pressure was measured simultaneously, allowing identification of the lung volume above residual volume at which there was an inflection point in the pressure-volume curve. Combined resident gas and bolus SBWTs in recumbent dogs were found to be different from such tests in humans; in dogs, the regional distribution of ventilation was not primarily determined by gravity. The measurements did not make it possible to discern exact mechanisms of filling and emptying, but both processes appear to be related to lung, thorax, and mediastinum interactions and/or differences in regional mechanical properties of the lungs.

  1. NICMOS Focus and HST Breathing

    NASA Astrophysics Data System (ADS)

    Suchkov, A.; Hershey, J.

    1998-09-01

    The program 7608 monitored on a biweekly basis NICMOS camera foci from June 9, 1997, through February 18, 1998. Each of the biweekly observations included 17 measurements of focus position (focus sweeps), individually for each of the three cameras. The measurements for camera 1 and camera 3 foci covered one or two HST orbital periods. Comparison of these measurements with the predictions of the three OTA focus breathing models has shown the following. (1). Focus variations seen in NICMOS focus sweeps correlate well with the OTA focus thermal breathing as predicted by breathing models (“4- temperature”, “full-temperature”, and “attitude” models). Thus they can be attributed mostly to the HST orbital temperature variation. (2). The amount of breathing (breathing amplitude) has been found to be on average larger in the first orbit after a telescope slew to a new target. This is explained as being due to additional thermal perturbations caused by the change in the HST attitude as the telescope repoints to a new target. (3). In the first orbit, the amount of focus change predicted by the 4-temperature model is about the same as that seen in the focus sweeps data (breathing scale factor ~1). However the full-temperature model predicts a two times smaller breathing amplitude (breathing scale factor ~1.7). This suggests that the light shield temperatures are more responsive to the attitude change than temperatures from the other temperature sensors. The results of this study may help to better understand the HST thermal cycles and to improve the models describing the impact of those on both the OTA and NICMOS focus.

  2. Evaluation of innovative state and community alcohol projects : breath alcohol testing program effectiveness, impact and transferability

    DOT National Transportation Integrated Search

    1987-03-01

    Breath Alcohol Testing (BAT) programs in Albuquerque and Santa Fe, New Mexico are evaluated in regard to effectiveness, impact, and transferability of the special DWI enforcement squads and their use of BAT Mobiles. Squad activity effectiveness is me...

  3. 9. "TEST STANDS NOS. 11, 13, & 15; CONCRETE STRUCTURAL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. "TEST STANDS NOS. 1-1, 1-3, & 1-5; CONCRETE STRUCTURAL SECTIONS AND DETAILS." Specifications No. ENG 04-35350-10; Drawing No. 60-09-04; no sheet number within title block. D.O. SERIES 1109/13. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract DA-04353 Eng. 177, no change; Date: 17 Dec. 1951. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-5, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  4. Analysis of Exhaled Breath for Disease Detection

    NASA Astrophysics Data System (ADS)

    Amann, Anton; Miekisch, Wolfram; Schubert, Jochen; Buszewski, Bogusław; Ligor, Tomasz; Jezierski, Tadeusz; Pleil, Joachim; Risby, Terence

    2014-06-01

    Breath analysis is a young field of research with great clinical potential. As a result of this interest, researchers have developed new analytical techniques that permit real-time analysis of exhaled breath with breath-to-breath resolution in addition to the conventional central laboratory methods using gas chromatography-mass spectrometry. Breath tests are based on endogenously produced volatiles, metabolites of ingested precursors, metabolites produced by bacteria in the gut or the airways, or volatiles appearing after environmental exposure. The composition of exhaled breath may contain valuable information for patients presenting with asthma, renal and liver diseases, lung cancer, chronic obstructive pulmonary disease, inflammatory lung disease, or metabolic disorders. In addition, oxidative stress status may be monitored via volatile products of lipid peroxidation. Measurement of enzyme activity provides phenotypic information important in personalized medicine, whereas breath measurements provide insight into perturbations of the human exposome and can be interpreted as preclinical signals of adverse outcome pathways.

  5. Improved fireman's compressed air breathing system pressure vessel development program

    NASA Technical Reports Server (NTRS)

    King, H. A.; Morris, E. E.

    1973-01-01

    Prototype high pressure glass filament-wound, aluminum-lined pressurant vessels suitable for use in a fireman's compressed air breathing system were designed, fabricated, and acceptance tested in order to demonstrate the feasibility of producing such high performance, lightweight units. The 4000 psi tanks have a 60 standard cubic foot (SCF) air capacity, and have a 6.5 inch diamter, 19 inch length, 415 inch volume, weigh 13 pounds when empty, and contain 33 percent more air than the current 45 SCF (2250 psi) steel units. The current steel 60 SCF (3000 psi) tanks weigh approximately twice as much as the prototype when empty, and are 2 inches, or 10 percent shorter. The prototype units also have non-rusting aluminum interiors, which removes the hazard of corrosion, the need for internal coatings, and the possibility of rust particles clogging the breathing system.

  6. Natural 18O and 13C-urea in gastric juice: a new route for non-invasive detection of ulcers.

    PubMed

    Maity, Abhijit; Pal, Mithun; Som, Suman; Maithani, Sanchi; Chaudhuri, Sujit; Pradhan, Manik

    2017-01-01

    The 13 C-urea breath test ( 13 C-UBT), developed a few decades ago, is widely used as a non-invasive diagnostic method to detect only the presence of the gastric pathogen Helicobacter pylori infection; however, the actual disease state, i.e. whether the person harbouring H. pylori has peptic ulcer disease (PUD) or non-ulcerous dyspepsia (NUD), is still poorly understood. Nevertheless, the present 13 C-UBT has numerous limitations, drawbacks and pitfalls owing to the ingestion of 13 C-labelled external urea. Here, we show that H. pylori is able to utilize the natural 13 C and 18 O-urea inherently present in the gastric juice in humans for its urease activity which has never been explored before. In vitro measurements of isotopic fractionations of gastric juice urea provide new insights into the actual state of the infection of PUD or NUD. We also provide evidence of the unusual 13 C and 18 O-isotopic fractionations of breath CO 2 that are distinctively altered in individuals with PUD encompassing both gastric and duodenal ulcers as well as with NUD by the enzymatic activity of H. pylori in the gastric niche without oral administration of any 13 C-enriched external urea. This deepens our understanding of the UBT exploiting the natural 13 C and 18 O-gastric juice urea in the pathogenesis of H. pylori infection, reveals the actual disease state of PUD or NUD and thus offers novel opportunities for a simple, robust, cost-effective and non-toxic global strategy devoid of any 13 C-enriched urea for treating these common diseases by a single breath test. Graphical Abstract Urea breath test without any external urea.

  7. PERIODIC AIR-BREATHING BEHAVIOUR IN A PRIMITIVE FISH REVEALED BY SPECTRAL ANALYSIS

    PubMed

    Hedrick; Katz; Jones

    1994-12-01

    The ventilatory patterns of air-breathing fish are commonly described as 'arrhythmic' or 'irregular' because the variable periods of breath-holding are punctuated by seemingly unpredictable air-breathing events (see Shelton et al. 1986). This apparent arrhythmicity contrasts with the perceived periodism or regularity in the gill ventilation patterns of some fish and with lung ventilation in birds and mammals. In this sense, periodism refers to behaviour that occurs with a definite, recurring interval (Bendat and Piersol, 1986). The characterisation of aerial ventilation patterns in fish as 'aperiodic' has been generally accepted on the basis of qualitative examination and it remains to be validated with rigorous testing. The bowfin, Amia calva (L.), is a primitive air-breathing fish that makes intermittent excursions to the air­water interface to gulp air, which is transferred to its well-vascularized gas bladder. Its phylogenetic position as the only extant member of the sister lineage of modern teleosts affords a unique opportunity to examine the evolution of aerial ventilation and provides a model for the examination of ventilatory patterns in primitive fishes. To establish whether Amia calva exhibit a particular pattern of air-breathing, we examined time series records of aerial ventilations from undisturbed fish over long periods (8 h). These records were the same as those used to calculate average ventilation intervals under a variety of experimental conditions (Hedrick and Jones, 1993). Their study also reported the occurrence of two distinct breath types. Type I breaths were characterised by an exhalation followed by an inhalation, whereas type II breaths were characterised by inhalation only. It was also hypothesized that the type I breaths were employed to meet oxygen demands, whereas the type II breaths were used to regulate gas bladder volume. However, they did not investigate the potential presence of a periodic ventilatory pattern. We now report

  8. Carbon-14 urea breath test for the diagnosis of Campylobacter pylori associated gastritis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marshall, B.J.; Surveyor, I.

    1988-01-01

    Urease in the human gastric mucosa is a marker for infection with Campylobacter pylori (CP), an organism suspected of causing chronic gastritis and peptic ulceration. To detect gastric urease, we examined 32 patients who were being evaluated for possible peptic ulcer disease. Fasting patients were given 10 microCi (370 kBq) of /sup 14/C-labeled urea. Breath samples were collected in hyamine at intervals between 1 and 30 min. The amount of /sup 14/C collected at these times was expressed as: body weight X (% of administered dose of /sup 14/C in sample)/(mmol of CO/sub 2/ collected). The presence of C. pylorimore » colonization was also determined by examination of multiple endoscopic gastric biopsy specimens. On average, patients who were proven to have C. pylori infection exhaled 20 times more labeled CO/sub 2/ than patients who were not infected. The difference between infected patients and C. pylori negative control patients was highly significant at all time points between 2 and 30 min after ingestion of the radionuclide (p less than 0.0001). The noninvasive urea breath is less expensive than endoscopic biopsy of the stomach and more accurate than serology as a means of detecting Campylobacter pylori infection. Because the test detects actual viable CP organisms, it can be used to confirm eradication of the bacterium after antibacterial therapy.« less

  9. Sleep-disordered Breathing in Cardiac Rehabilitation: Prevalence, Predictors, and Influence on the Six-Minute Walk Test.

    PubMed

    Loo, Germaine; Chua, Ai-Ping; Tay, Hung-Yong; Poh, Ruth; Tai, Bee-Choo; Lee, Chi-Hang

    2016-06-01

    Identification of non-traditional risk factors is an important component of cardiac rehabilitation (CR). However, the prevalence and predictors of sleep-disordered breathing (SDB) and its influence on exercise performance in patients attending CR remain poorly described. Patients enrolled in a national CR centre were eligible for a comprehensive SDB screening program. Screening questionnaires for SDB, overnight sleep study, and the 6-minute walk test (6MWT) were conducted. We recruited 332 patients (mean age 62±10 years, 62.4% male) attending CR for primary (29.2%) or secondary (70.8%) prevention, of which 209 successfully completed the overnight sleep study. Sleep-disordered breathing group patients (n=68, 32.5%) were older and had a higher body mass index (BMI) and neck and waist circumferences than the non-SDB group patients. After adjusting for neck and waist circumference, age (OR=1.06; 95% CI 1.02-1.10; p=0.001) and BMI (OR=1.19; 95% CI 1.10-1.30; p<0.001) remained independent predictors of SDB. A high risk of SDB based on the Berlin Questionnaire (43.4% versus 35.5%, p=0.277) or STOP-BANG questionnaire (63.2% versus 53.2%, p=0.170) and excessive daytime sleepiness (Epworth Sleepiness Scale >10, 23.9% versus 17.7%, p=0.297) were similar between the groups. The 6MWT scores were significantly lower in the SDB than non-SDB group (mean difference -32 m; 95% CI -57-7; p=0.013). The relationship was no longer significant after adjusting for age, sex, and waist circumference. Sleep-disordered breathing is prevalent in CR patients and is independently predicted by ageing and obesity. The association between SDB and poorer exercise performance may be explained by age, sex, and waist circumference. Copyright © 2015 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  10. Do elite breath-hold divers suffer from mild short-term memory impairments?

    PubMed

    Billaut, François; Gueit, Patrice; Faure, Sylvane; Costalat, Guillaume; Lemaître, Frédéric

    2018-03-01

    Repeated apneas are associated with severe hypoxemia that may ultimately lead to loss of consciousness in some breath-hold divers. Despite increasing number of practitioners, the relationship between apnea-induced hypoxia and neurocognitive functions is still poorly understood in the sport of free diving. To shed light onto this phenomenon, we examined the impact of long-term breath-hold diving training on attentional processing, short-term memory, and long-term mnesic and executive functions. Thirty-six men matched for age, height, and weight were separated into the following 3 groups: (i) 12 elite breath-hold divers (EBHD), mean static apnea best time 371 s, 105 months mean apnea experience; (ii) 12 novice breath-hold divers, mean best time 243 s, 8.75 months mean apnea experience; and (iii) 12 physical education students with no breath-hold diving experience; all of these participants performed varied written and computerized neuropsychological tasks. Compared with the 2 other groups, the EBHD group was slower to complete the interference card during a Stroop test (F [1,33] = 4.70, p < 0.05), and presented more errors on the interference card (F [1,33] = 2.96, p < 0.05) and a lower total interference score (F [1,33] = 5.64, p < 0.05). The time to complete the interference card test was positively correlated with maximal static apnea duration (r = 0.73, p < 0.05) and the number of years of breath-hold diving training (r = 0.79, p < 0.001). These findings suggest that breath-hold diving training over several years may cause mild, but persistent, short-term memory impairments.

  11. Ventilatory Responses at Peak Exercise in Endurance-Trained Obese Adults

    PubMed Central

    Lorenzo, Santiago

    2013-01-01

    Background: Alterations in respiratory mechanics predispose healthy obese individuals to low lung volume breathing, which places them at risk of developing expiratory flow limitation (EFL). The high ventilatory demand in endurance-trained obese adults further increases their risk of developing EFL and increases their work of breathing. The objective of this study was to investigate the prevalence and magnitude of EFL in fit obese (FO) adults via measurements of breathing mechanics and ventilatory dynamics during exercise. Methods: Ten (seven women and three men) FO (mean ± SD, 38 ± 5 years, 38% ± 5% body fat) and 10 (seven women and three men) control obese (CO) (38 ± 5 years, 39% ± 5% body fat) subjects underwent hydrostatic weighing, pulmonary function testing, cycle exercise testing, and the determination of the oxygen cost of breathing during eucapnic voluntary hyperpnea. Results: There were no differences in functional residual capacity (43% ± 6% vs 40% ± 9% total lung capacity [TLC]), residual volume (21% ± 4% vs 21% ± 4% TLC), or FVC (111% ± 13% vs 104% ± 15% predicted) between FO and CO subjects, respectively. FO subjects had higher FEV1 (111% ± 13% vs 99% ± 11% predicted), TLC (106% ± 14% vs 94% ± 7% predicted), peak expiratory flow (123% ± 14% vs 106% ± 13% predicted), and maximal voluntary ventilation (128% ± 15% vs 106% ± 13% predicted) than did CO subjects. Peak oxygen uptake (129% ± 16% vs 86% ± 15% predicted), minute ventilation (128 ± 35 L/min vs 92 ± 25 L/min), and work rate (229 ± 54 W vs 166 ± 55 W) were higher in FO subjects. Mean inspiratory (4.65 ± 1.09 L/s vs 3.06 ± 1.21 L/s) and expiratory (4.15 ± 0.95 L/s vs 2.98 ± 0.76L/s) flows were greater in FO subjects, which yielded a greater breathing frequency (51 ± 8 breaths/min vs 41 ± 10 breaths/min) at peak exercise in FO subjects. Mechanical ventilatory constraints in FO subjects were similar to those in CO subjects despite the greater ventilatory demand in FO

  12. Ventilatory responses at peak exercise in endurance-trained obese adults.

    PubMed

    Lorenzo, Santiago; Babb, Tony G

    2013-10-01

    Alterations in respiratory mechanics predispose healthy obese individuals to low lung volume breathing, which places them at risk of developing expiratory flow limitation (EFL). The high ventilatory demand in endurance-trained obese adults further increases their risk of developing EFL and increases their work of breathing. The objective of this study was to investigate the prevalence and magnitude of EFL in fit obese (FO) adults via measurements of breathing mechanics and ventilatory dynamics during exercise. Ten (seven women and three men) FO (mean ± SD, 38 ± 5 years, 38% ± 5% body fat) and 10 (seven women and three men) control obese (CO) (38 ± 5 years, 39% ± 5% body fat) subjects underwent hydrostatic weighing, pulmonary function testing, cycle exercise testing, and the determination of the oxygen cost of breathing during eucapnic voluntary hyperpnea. There were no differences in functional residual capacity (43% ± 6% vs 40% ± 9% total lung capacity [TLC]), residual volume (21% ± 4% vs 21% ± 4% TLC), or FVC (111% ± 13% vs 104% ± 15% predicted) between FO and CO subjects, respectively. FO subjects had higher FEV1 (111% ± 13% vs 99% ± 11% predicted), TLC (106% ± 14% vs 94% ± 7% predicted), peak expiratory flow (123% ± 14% vs 106% ± 13% predicted), and maximal voluntary ventilation (128% ± 15% vs 106% ± 13% predicted) than did CO subjects. Peak oxygen uptake (129% ± 16% vs 86% ± 15% predicted), minute ventilation (128 ± 35 L/min vs 92 ± 25 L/min), and work rate (229 ± 54 W vs 166 ± 55 W) were higher in FO subjects. Mean inspiratory (4.65 ± 1.09 L/s vs 3.06 ± 1.21 L/s) and expiratory (4.15 ± 0.95 L/s vs 2.98 ± 0.76 L/s) flows were greater in FO subjects, which yielded a greater breathing frequency (51 ± 8 breaths/min vs 41 ± 10 breaths/min) at peak exercise in FO subjects. Mechanical ventilatory constraints in FO subjects were similar to those in CO subjects despite the greater ventilatory demand in FO subjects. FO individuals achieve

  13. Electrospun polystyrene/graphene nanofiber film as a novel adsorbent of thin film microextraction for extraction of aldehydes in human exhaled breath condensates.

    PubMed

    Huang, Jing; Deng, Hongtao; Song, Dandan; Xu, Hui

    2015-06-09

    In the current study, we introduced a novel polystyrene/graphene (PS/G) composite nanofiber film for thin film microextraction (TFME) for the first time. The PS/G nanofiber film was fabricated on the surface of filter paper by a facile electrospinning method. The morphology and extraction performance of the resultant composite film were investigated systematically. The PS/G nanofiber film exhibited porous fibrous structure, large surface area and strong hydrophobicity. A new thin film microextraction-high performance liquid chromatography (TFME-HPLC) method was developed for the determination of six aldehydes in human exhaled breath condensates. The method showed high enrichment efficiency and fast analysis speed. Under the optimal conditions, the linear ranges of the analytes were in the range of 0.02-30 μmol L(-1) with correlation coefficients above 0.9938, and the recoveries were between 79.8% and 105.6% with the relative standard deviation values lower than 16.3% (n=5). The limits of quantification of six aldehydes ranged from 13.8 to 64.6 nmol L(-1). The established method was successfully applied for the quantification of aldehyde metabolites in exhaled breath condensates of lung cancer patients and healthy people. Taken together, the TFME-HPLC method provides a simple, rapid, sensitive, cost-effective, non-invasion approach for the analysis of linear aliphatic aldehydes in human exhaled breath condensates. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Relationship between sleep-disordered breathing and renal dysfunction in acute coronary syndrome.

    PubMed

    Kiyokuni, Masayoshi; Kawashima, Chika; Konishi, Masaaki; Sakamaki, Kentaro; Iwata, Kiwamu; Nakayama, Naoki; Komura, Naohiro; Kosuge, Masami; Sugano, Teruyasu; Ishigami, Tomoaki; Endo, Tsutomu; Ishikawa, Toshiyuki; Yamanaka, Takeharu; Kimura, Kazuo; Tamura, Kouichi

    2018-02-01

    Sleep-disordered breathing (SDB) is associated with cardiovascular complications. However, the effect of SDB on renal function in patients with acute coronary syndrome (ACS) treated by percutaneous coronary intervention (PCI) remains unclear. We enrolled 154 consecutive ACS patients without heart failure. A sleep study was performed immediately after PCI. The mean apnea-hypopnea index (AHI) was 16.4±13.1, and 33 patients (21%) had severe SDB, defined as AHI≥25. Estimated glomerular filtration rate (eGFR) values on admission (60±12mL/min/1.73m 2 vs. 67±17mL/min/1.73m 2 , p=0.046) and at discharge (54±15mL/min/1.73m 2 vs. 63±15mL/min/1.73m 2 , p=0.002) were lower in patients with severe SDB than in those patients without severe SDB. Multiple linear regression analysis showed that AHIs were significantly correlated with absolute changes in eGFR values from admission to discharge (β=0.201, p=0.004). Median 24-h urinary noradrenaline excretion measured on the same day of the sleep study was higher [297 (interquartile range {IQR}: 232-472) vs. 174 (IQR: 107-318)μg/day, p=0.021] in patients with severe SDB. On multivariate logistic regression analysis, the presence of severe SDB was a significant predictor (adjusted odds ratio 3.76, 95% confidence interval 1.06-13.9, p=0.047) for eGFR of less than 45mL/min/1.73m 2 at discharge. This association was independent of age, eGFR on admission, and a presentation of ST-segment elevation myocardial infarction. In patients with ACS who undergo PCI, severe SDB is associated with impaired renal function on admission and its deterioration during hospitalization. Further studies will be needed to conclude that SDB would be a therapeutic target in ACS. Copyright © 2017. Published by Elsevier Ltd.

  15. The effect of ß-1,3-glucan derived from Euglena gracilis (Algamune™) on the innate immunological responses of Nile tilapia (Oreochromis niloticus L.)

    USDA-ARS?s Scientific Manuscript database

    Algamune™ is a commercial feed additive derived from Euglena gracilis, providing a rich source of the ß-1,3-glucan paramylon. Isolated kidney phagocytes of Nile tilapia were incubated with graded doses (0, 8, 16, 32, 64, and 128 µg mL-1) of Algamune™ and purified ß-1,3-glucan paramylon to gauge the...

  16. Sensitive Spectroscopic Analysis of Biomarkers in Exhaled Breath

    NASA Astrophysics Data System (ADS)

    Bicer, A.; Bounds, J.; Zhu, F.; Kolomenskii, A. A.; Kaya, N.; Aluauee, E.; Amani, M.; Schuessler, H. A.

    2018-06-01

    We have developed a novel optical setup which is based on a high finesse cavity and absorption laser spectroscopy in the near-IR spectral region. In pilot experiments, spectrally resolved absorption measurements of biomarkers in exhaled breath, such as methane and acetone, were carried out using cavity ring-down spectroscopy (CRDS). With a 172-cm-long cavity, an efficient optical path of 132 km was achieved. The CRDS technique is well suited for such measurements due to its high sensitivity and good spectral resolution. The detection limits for methane of 8 ppbv and acetone of 2.1 ppbv with spectral sampling of 0.005 cm-1 were achieved, which allowed to analyze multicomponent gas mixtures and to observe absorption peaks of 12CH4 and 13CH4. Further improvements of the technique have the potential to realize diagnostics of health conditions based on a multicomponent analysis of breath samples.

  17. The role of size in synchronous air breathing of Hoplosternum littorale.

    PubMed

    Sloman, Katherine A; Sloman, Richard D; De Boeck, Gudrun; Scott, Graham R; Iftikar, Fathima I; Wood, Chris M; Almeida-Val, Vera M F; Val, Adalberto L

    2009-01-01

    Synchronized air breathing may have evolved as a way of minimizing the predation risk known to be associated with air breathing in fish. Little is known about how the size of individuals affects synchronized air breathing and whether some individuals are required to surface earlier than necessary in support of conspecifics, while others delay air intake. Here, the air-breathing behavior of Hoplosternum littorale held in groups or in isolation was investigated in relation to body mass, oxygen tensions, and a variety of other physiological parameters (plasma lactate, hepatic glycogen, hematocrit, hemoglobin, and size of heart, branchial basket, liver, and air-breathing organ [ABO]). A mass-specific relationship with oxygen tension of first surfacing was seen when fish were held in isolation; smaller individuals surfaced at higher oxygen tensions. However, this relationship was lost when the same individuals were held in social groups of four, where synchronous air breathing was observed. In isolation, 62% of fish first surfaced at an oxygen tension lower than the calculated P(crit) (8.13 kPa), but in the group environment this was reduced to 38% of individuals. Higher oxygen tensions at first surfacing in the group environment were related to higher levels of activity rather than any of the physiological parameters measured. In fish held in isolation but denied access to the water surface for 12 h before behavioral testing, there was no mass-specific relationship with oxygen tension at first surfacing. Larger individuals with a greater capacity to store air in their ABOs may, therefore, remain in hypoxic waters for longer periods than smaller individuals when held in isolation unless prior access to the air is prevented. This study highlights how social interaction can affect air-breathing behaviors and the importance of considering both behavioral and physiological responses of fish to hypoxia to understand the survival mechanisms they employ.

  18. High-pitched breath sounds indicate airflow limitation in asymptomatic asthmatic children.

    PubMed

    Habukawa, Chizu; Nagasaka, Yukio; Murakami, Katsumi; Takemura, Tsukasa

    2009-04-01

    Asthmatic children may have airway dysfunction even when asymptomatic, indicating that their long-term treatment is less than optimal. Although airway dysfunction can be identified on lung function testing, performing these tests can be difficult in infants. We studied whether breath sounds reflect subtle airway dysfunction in asthmatic children. The highest frequency of inspiratory breaths sounds (HFI) and the highest frequency of expiratory breath sounds (HFE) were measured in 131 asthmatic children while asymptomatic and with no wheezes for more than 2 weeks. No child was being treated with inhaled corticosteroids (ICS). Breath sounds were recorded and analysed by sound spectrography and compared with spirometric parameters. After initial evaluation, cases with more than step 2 (mild persistent) asthma were treated using inhaled fluticasone (100-200 microg/day) for 1 month, and then breath sound analysis and pulmonary function testing were repeated. On initial evaluation, HFI correlated with the percentage of predicted FEF(50) (%FEF(50)), (r = -0.45, P < 0.001), the percentage of predicted FEF(75) (%FEF(75)) (r = -0.456, P < 0.001), and FEV(1) as a percentage of FVC (FEV(1)/FVC (%)) (r = -0.32, P < 0.001). HFI did not correlate with the percentage of predicted PEF (%PEF). The 69 children with lower than normal %FEF(50) were then treated with ICS. The %FEF(50) and %FEF(75) improved after ICS treatment, and increases in %FEF(50) (P < 0.005) correlated with decreases in HFI (P < 0.001). Higher HFI in asymptomatic asthmatic children may indicate small airway obstruction. Additional ICS treatment may improve the pulmonary function indices representing small airway function with simultaneous HFI decreases in such patients.

  19. Improved ROS defense in the swimbladder of a facultative air-breathing erythrinid fish, jeju, compared to a non-air-breathing close relative, traira.

    PubMed

    Pelster, Bernd; Giacomin, Marina; Wood, Chris M; Val, Adalberto L

    2016-07-01

    The jeju Hoplerythrinus unitaeniatus and the traira Hoplias malabaricus are two closely related erythrinid fish, both possessing a two-chambered physostomous swimbladder. In the jeju the anterior section of the posterior bladder is highly vascularized and the swimbladder is used for aerial respiration; the traira, in turn, is a water-breather that uses the swimbladder as a buoyancy organ and not for aerial oxygen uptake. Observation of the breathing behavior under different levels of water oxygenation revealed that the traira started aquatic surface respiration only under severe hypoxic conditions and did not breathe air. In the jeju air-breathing behavior was observed under normoxic conditions, and the frequency of air-breathing was significantly increased under hypoxic conditions. Unexpectedly, even under hyperoxic conditions (30 mg O2 L(-1)) the jeju continued to take air breaths, and compared with normoxic conditions the frequency was not reduced. Because the frequently air-exposed swimbladder tissue faces higher oxygen partial pressures than normally experienced by other fish tissues, it was hypothesized that in the facultative air-breathing jeju, swimbladder tissue would have a higher antioxidative capacity than the swimbladder tissue of the water breathing traira. Measurement of total glutathione (GSSG/GSH) concentration in anterior and posterior swimbladder tissue revealed a higher concentration of this antioxidant in swimbladder tissue as compared to muscle tissue in the jeju. Furthermore, the GSSG/GSH concentration in jeju tissues was significantly higher than in traira tissues. Similarly, activities of enzymes involved in the breakdown of reactive oxygen species were significantly higher in the jeju swimbladder as compared to the traira swimbladder. The results show that the jeju, using the swimbladder as an additional breathing organ, has an enhanced antioxidative capacity in the swimbladder as compared to the traira, using the swimbladder only as a

  20. Breath-collection device for delayed breath-alcohol analysis

    DOT National Transportation Integrated Search

    1980-12-01

    The report includes the details of a study to develop, evaluate, and validate a breath collection device (BCD) for delayed breath-alcohol analysis. Primary applications of the BCD include collection of breath-alcohol samples for field surveys or for ...

  1. Recombination Creates Novel L1 (Line-1) Elements in Rattus Norvegicus

    PubMed Central

    Hayward, B. E.; Zavanelli, M.; Furano, A. V.

    1997-01-01

    Mammalian L1 (long interspersed repeated DNA, LINE-1) retrotransposons consist of a 5' untranslated region (UTR) with regulatory properties, two protein encoding regions (ORF I, ORF II, which encodes a reverse transcriptase) and a 3' UTR. L1 elements have been evolving in mammals for >100 million years and this process continues to generate novel L1 subfamilies in modern species. Here we characterized the youngest known subfamily in Rattus norvegicus, L1(mlvi2), and unexpectedly found that this element has a dual ancestry. While its 3' UTR shares the same lineage as its nearest chronologically antecedent subfamilies, L1(3) and L1(4), its ORF I sequence does not. The L1(mlvi2) ORF I was derived from an ancestral ORF I sequence that was the evolutionary precursor of the L1(3) and L1(4) ORF I. We suggest that an ancestral ORF I sequence was recruited into the modern L1(mlvi2) subfamily by recombination that possibly could have resulted from template strand switching by the reverse transcriptase during L1 replication. This mechanism could also account for some of the structural features of rodent L1 5' UTR and ORF I sequences including one of the more dramatic features of L1 evolution in mammals, namely the repeated acquisition of novel 5' UTRs. PMID:9178013

  2. 42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100 Section 84.100 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL...-Contained Breathing Apparatus § 84.100 Man tests 1, 2, 3, and 4; requirements. Man tests 1, 2, 3, and 4, set...

  3. 42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100 Section 84.100 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL...-Contained Breathing Apparatus § 84.100 Man tests 1, 2, 3, and 4; requirements. Man tests 1, 2, 3, and 4, set...

  4. 42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100 Section 84.100 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL...-Contained Breathing Apparatus § 84.100 Man tests 1, 2, 3, and 4; requirements. Man tests 1, 2, 3, and 4, set...

  5. TESTS - APOLLO 13

    NASA Image and Video Library

    1970-06-10

    S70-41983 (June 1970) --- Second photograph in sequence of three of panel separation test at Langley Research Center. The test was part of the Apollo 13 post flight investigation of the Service Module explosion incident. Photo credit: NASA

  6. Liver diffusivity in healthy volunteers and patients with chronic liver disease: Comparison of breath-hold and free-breathing techniques

    PubMed Central

    Eatesam, Mamak; Noworolski, Susan M; Tien, Phyllis C; Nystrom, Michelle; Dodge, Jennifer L.; Merriman, Raphael B.; Qayyum, Aliya

    2011-01-01

    Purpose To compare liver ADC obtained with breath-hold and free-breathing diffusion weighted imaging (DWI) in healthy volunteers and patients with liver disease. Materials and Methods Twenty-eight subjects, 12 healthy volunteers and 16 patients (9 NAFLD, 7 chronic active HCV), underwent breath-hold (BH) and free-breathing (FB) DWI MRI at 1.5T. Pearson’s correlation coefficient was used to determine correlation while paired t-tests assessed differences between BH and FB ADC. Estimated bias was calculated using the Bland-Altman method. Results Liver ADC (×10−3 mm2/sec) was lower on BH for all groups (mean difference 0.36±0.20; p<0.01). ADC was higher in healthy volunteers (BH 1.80±0.18; FB 2.24±0.20) compared to NAFLD patients (BH 1.43±0.27; FB 1.78±0.28) (p<0.001) and HCV patients (BH 1.63±0.191; FB 1.88±0.12). Overall correlation between BH and FB ADC was (r =0.75), greatest in NAFLD (r =0.90) compared to the correlation in HCV (r =0.24) and healthy subjects (r =0.34). Bland-Altman plots did not show agreement in mean absolute difference and estimated bias between subjects. Conclusion Correlation between BH and FB liver ADC is moderate indicating that BH and FB should not be used interchangeably. Additionally, the lower ADC values in BH versus FB should be accounted for when comparing different liver DWI studies. PMID:22034200

  7. 3D Late Gadolinium Enhancement in a Single Prolonged Breath-hold using Supplemental Oxygenation and Hyperventilation

    PubMed Central

    Roujol, Sébastien; Basha, Tamer A.; Akçakaya, Mehmet; Foppa, Murilo; Chan, Raymond H.; Kissinger, Kraig V.; Goddu, Beth; Berg, Sophie; Manning, Warren J.; Nezafat, Reza

    2013-01-01

    Purpose: To evaluate the feasibility of 3D single breath-hold late gadolinium enhancement (LGE) of the left ventricle (LV) using supplemental oxygen and hyperventilation and compressed-sensing acceleration. Methods: Breath-hold metrics (breath-hold duration, diaphragmatic/LV position drift, and maximum variation of RR interval) without and with supplemental oxygen and hyperventilation were assessed in healthy adult subjects using a real time single shot acquisition. Ten healthy subjects and 13 patients then underwent assessment of the proposed 3D breath-hold LGE acquisition (FOV=320×320×100 mm3, resolution=1.6×1.6×5.0 mm3, acceleration rate of 4) and a free breathing acquisition with right hemidiaphragm navigator (NAV) respiratory gating. Semi-quantitative grading of overall image quality, motion artifact, myocardial nulling, and diagnostic value was performed by consensus of two blinded observers. Results: Supplemental oxygenation and hyperventilation increased the breath-hold duration (35±11 s to 58±21 s, p<0.0125) without significant impact on diaphragmatic/LV position drift or maximum variation of RR interval (both p>0.01). LGE images were of similar quality when compared to free breathing acquisitions but with reduced total scan time (85±22 s to 35±6 s, p<0.001). Conclusions: Supplemental oxygenation and hyperventilation allow for prolonged breath-holding and enable single breath-hold 3D accelerated LGE with similar image quality as free breathing with NAV. PMID:24186772

  8. In vitro evaluation of heat and moisture exchangers designed for spontaneously breathing tracheostomized patients.

    PubMed

    Brusasco, Claudia; Corradi, Francesco; Vargas, Maria; Bona, Margherita; Bruno, Federica; Marsili, Maria; Simonassi, Francesca; Santori, Gregorio; Severgnini, Paolo; Kacmarek, Robert M; Pelosi, Paolo

    2013-11-01

    Heat and moisture exchangers (HMEs) are commonly used in chronically tracheostomized spontaneously breathing patients, to condition inhaled air, maintain lower airway function, and minimize the viscosity of secretions. Supplemental oxygen (O2) can be added to most HMEs designed for spontaneously breathing tracheostomized patients. We tested the efficiency of 7 HMEs designed for spontaneously breathing tracheostomized patients, in a normothermic model, at different minute ventilations (VE) and supplemental O2 flows. HME efficiency was evaluated using an in vitro lung model at 2 VE (5 and 15 L/min) and 4 supplemental O2 flows (0, 3, 6, and 12 L/min). Wet and dry temperatures of the inspiratory flow were measured, and absolute humidity was calculated. In addition, HME efficiency at 0, 12, and 24 h use was evaluated, as well as resistance to flow at 0 and 24 h. The progressive increase in O2 flow from 0 to 12 L/min was associated with a reduction in temperature and absolute humidity. Under the same conditions, this effect was greater at lower VE. The HME with the best performance provided an absolute humidity of 26 mg H2O/L and a temperature of 27.8 °C. No significant changes in efficiency or resistance were detected during the 24 h evaluation. The efficiency of HMEs in terms of temperature and absolute humidity is significantly affected by O2 supplementation and V(E).

  9. Effect of short-term acclimatization to high altitude on sleep and nocturnal breathing.

    PubMed

    Nussbaumer-Ochsner, Yvonne; Ursprung, Justyna; Siebenmann, Christoph; Maggiorini, Marco; Bloch, Konrad E

    2012-03-01

    Objective physiologic data on sleep and nocturnal breathing at initial exposure and during acclimatization to high altitude are scant. We tested the hypothesis that acute exposure to high altitude induces quantitative and qualitative changes in sleep and that these changes are partially reversed with acclimatization. Prospective observation. One night in a sleep laboratory at 490 meters, the first and the third night in a mountain hut at 4559 meters. Sixteen healthy mountaineers. Altitude exposure. Polysomnography, questionnaire evaluation of sleep and acute mountain sickness. Compared to 490 m, median nocturnal oxygen saturation decreased during the 1st night at 4559 m from 96% to 67%, minute ventilation increased from 4.4 to 6.3 L/min, and the apnea-hypopnea index increased from 0.1 to 60.9/h; correspondingly, sleep efficiency decreased from 93% to 69%, and slow wave sleep from 18% to 6% (P < 0.05, all instances). During the 3rd night at 4559 m, oxygen saturation was 71%, slow wave sleep 11% (P < 0.05 vs. 1st night, both instances) and the apnea/hypopnea index was 86.5/h (P = NS vs. 1st night). Symptoms of AMS and of disturbed sleep were significantly reduced in the morning after the 3rd vs. the 1st night at 4559 m. In healthy mountaineers ascending rapidly to high altitude, sleep quality is initially impaired but improves with acclimatization in association with improved oxygen saturation, while periodic breathing persists. Therefore, high altitude sleep disturbances seem to be related predominantly to hypoxemia rather than to periodic breathing.

  10. 16 CFR 1210.13 - Certification tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Certification tests. 1210.13 Section 1210.13... STANDARD FOR CIGARETTE LIGHTERS Certification Requirements § 1210.13 Certification tests. (a) General. As... reasonable testing programs shall include qualification tests, which must be performed on surrogates of each...

  11. Insulin sensitivity index (ISI0, 120) potentially linked to carbon isotopes of breath CO2 for pre-diabetes and type 2 diabetes

    PubMed Central

    Ghosh, Chiranjit; Mukhopadhyay, Prabuddha; Ghosh, Shibendu; Pradhan, Manik

    2015-01-01

    New strategies for an accurate and early detection of insulin resistance are important to delay or prevent the acute onset of type 2 diabetes (T2D). Currently, insulin sensitivity index (ISI0,120) is considered to be a viable invasive method of whole-body insulin resistance for use in clinical settings in comparison with other invasive sensitivity indexes like homeostasis model assessment (HOMA), and quantitative insulin sensitivity check index (QUICKI). To investigate how these sensitivity indexes link the 13C/12C-carbon isotopes of exhaled breath CO2 to pre-diabetes (PD) and type 2 diabetes in response to glucose ingestion, we studied excretion dynamics of 13C/12C-isotopic fractionations of breath CO2. Here, we show that 13C/12C-isotope ratios of breath CO2 were well correlated with blood glucose, insulin, glycosylated-hemoglobin as well as with HOMA-IR and 1/QUICKI. Conversely, the strongest correlation was observed between 1/ISI0,120 and breath CO2 isotopes. Consequently, we determined several optimal diagnostic cut-off points of 1/ISI0,120 and 13CO2/12CO2-isotope ratios to distinctively track the evolution of PD prior to the onset of T2D. Our findings suggest that isotopic breath CO2 is a novel method for accurate estimation of ISI0,120 and thus may open new perspectives into the isotope-specific non-invasive evaluation of insulin resistance for large-scale real-time diabetes screening purposes. PMID:26148706

  12. TESTS - APOLLO 13

    NASA Image and Video Library

    1970-06-10

    S70-41985 (15 June 1970) --- The third photograph in sequence of three showing panel separation test at Langley Research Center (LRC). The test was part of the Apollo 13 post flight investigation of the Service Module explosion incident. Photo credit: NASA

  13. 20 CFR 216.13 - Regular current connection test.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 1 2011-04-01 2011-04-01 false Regular current connection test. 216.13... ELIGIBILITY FOR AN ANNUITY Current Connection With the Railroad Industry § 216.13 Regular current connection test. An employee has a current connection with the railroad industry if he or she meets one of the...

  14. 20 CFR 216.13 - Regular current connection test.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 1 2010-04-01 2010-04-01 false Regular current connection test. 216.13... ELIGIBILITY FOR AN ANNUITY Current Connection With the Railroad Industry § 216.13 Regular current connection test. An employee has a current connection with the railroad industry if he or she meets one of the...

  15. 42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100...-Contained Breathing Apparatus § 84.100 Man tests 1, 2, 3, and 4; requirements. Man tests 1, 2, 3, and 4, set forth in Tables 1, 2, 3, and 4 of this subpart, respectively, prescribe the duration and sequence of...

  16. 21 CFR 862.3080 - Breath nitric oxide test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... fractional nitric oxide concentration in expired breath aids in evaluating an asthma patient's response to anti-inflammatory therapy, as an adjunct to established clinical and laboratory assessments of asthma...

  17. 40 CFR 721.10160 - Poly(oxy-1,2-ethanediyl), .alpha.-[(13Z)-1-oxo-13-docosen-1-yl]-.omega.-[[(13Z)-1-oxo-13-docosen...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ....-[(13Z)-1-oxo-13-docosen-1-yl]-.omega.-[[(13Z)-1-oxo-13-docosen-1-yl]oxy]-. 721.10160 Section 721.10160... Poly(oxy-1,2-ethanediyl), .alpha.-[(13Z)-1-oxo-13-docosen-1-yl]-.omega.-[[(13Z)-1-oxo-13-docosen-1-yl... substance identified as poly(oxy-1,2-ethanediyl), .alpha.-[(13Z)-1-oxo-13-docosen-1-yl]-.omega.-[[(13Z)-1...

  18. 40 CFR 721.10160 - Poly(oxy-1,2-ethanediyl), .alpha.-[(13Z)-1-oxo-13-docosen-1-yl]-.omega.-[[(13Z)-1-oxo-13-docosen...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....-[(13Z)-1-oxo-13-docosen-1-yl]-.omega.-[[(13Z)-1-oxo-13-docosen-1-yl]oxy]-. 721.10160 Section 721.10160... Poly(oxy-1,2-ethanediyl), .alpha.-[(13Z)-1-oxo-13-docosen-1-yl]-.omega.-[[(13Z)-1-oxo-13-docosen-1-yl... substance identified as poly(oxy-1,2-ethanediyl), .alpha.-[(13Z)-1-oxo-13-docosen-1-yl]-.omega.-[[(13Z)-1...

  19. 40 CFR 721.10160 - Poly(oxy-1,2-ethanediyl), .alpha.-[(13Z)-1-oxo-13-docosen-1-yl]-.omega.-[[(13Z)-1-oxo-13-docosen...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ....-[(13Z)-1-oxo-13-docosen-1-yl]-.omega.-[[(13Z)-1-oxo-13-docosen-1-yl]oxy]-. 721.10160 Section 721.10160... Poly(oxy-1,2-ethanediyl), .alpha.-[(13Z)-1-oxo-13-docosen-1-yl]-.omega.-[[(13Z)-1-oxo-13-docosen-1-yl... substance identified as poly(oxy-1,2-ethanediyl), .alpha.-[(13Z)-1-oxo-13-docosen-1-yl]-.omega.-[[(13Z)-1...

  20. 40 CFR 721.10160 - Poly(oxy-1,2-ethanediyl), .alpha.-[(13Z)-1-oxo-13-docosen-1-yl]-.omega.-[[(13Z)-1-oxo-13-docosen...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ....-[(13Z)-1-oxo-13-docosen-1-yl]-.omega.-[[(13Z)-1-oxo-13-docosen-1-yl]oxy]-. 721.10160 Section 721.10160... Poly(oxy-1,2-ethanediyl), .alpha.-[(13Z)-1-oxo-13-docosen-1-yl]-.omega.-[[(13Z)-1-oxo-13-docosen-1-yl... substance identified as poly(oxy-1,2-ethanediyl), .alpha.-[(13Z)-1-oxo-13-docosen-1-yl]-.omega.-[[(13Z)-1...

  1. 40 CFR 721.10160 - Poly(oxy-1,2-ethanediyl), .alpha.-[(13Z)-1-oxo-13-docosen-1-yl]-.omega.-[[(13Z)-1-oxo-13-docosen...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....-[(13Z)-1-oxo-13-docosen-1-yl]-.omega.-[[(13Z)-1-oxo-13-docosen-1-yl]oxy]-. 721.10160 Section 721.10160... Poly(oxy-1,2-ethanediyl), .alpha.-[(13Z)-1-oxo-13-docosen-1-yl]-.omega.-[[(13Z)-1-oxo-13-docosen-1-yl... substance identified as poly(oxy-1,2-ethanediyl), .alpha.-[(13Z)-1-oxo-13-docosen-1-yl]-.omega.-[[(13Z)-1...

  2. Heading for an economic industrial upgrading of crude glycerol from biodiesel production to 1,3-propanediol by Lactobacillus diolivorans.

    PubMed

    Pflügl, Stefan; Marx, Hans; Mattanovich, Diethard; Sauer, Michael

    2014-01-01

    Lactobacillus diolivorans was evaluated as a potential organism for production of 1,3-propanediol under industrially relevant conditions. Crude glycerol of different origins has been tested and showed no inhibitory effects on growth or production. Using crude glycerol from biodiesel production from palm oil 85 g/l 1,3-propanediol have been obtained with a productivity of 0.45 g/lh in a fed-batch cultivation. Sugar necessary for the formation of biomass was replaced with a hydrolysate from lignocellulosic material resulting in 75 g/l 1,3-propanediol and a productivity of 0.36 g/lh. Lignocellulosic hydrolysate contained the potential inhibitors furfural and 5-hydroxymethylfurfural at concentrations of 0.7 and 0.3 g/l, respectively. Addition of furfural and 5-hydroxymethylfurfural to batch cultures in said concentrations did not show inhibitory effects on growth or 1,3-propanediol production. Copyright © 2013. Published by Elsevier Ltd.

  3. How to breathe when you are short of breath

    MedlinePlus

    ... pursed lip breathing; Hypoxia - pursed lip breathing; Chronic respiratory failure - pursed lip breathing ... et al, eds. Murray and Nadel's Textbook of Respiratory Medicine . 6th ed. Philadelphia, PA: Elsevier Saunders; 2016: ...

  4. Extraribosomal L13a Is a Specific Innate Immune Factor for Antiviral Defense

    PubMed Central

    Poddar, Darshana; Basu, Abhijit; Kour, Ravinder; Verbovetskaya, Valentina

    2014-01-01

    ABSTRACT We report a novel extraribosomal innate immune function of mammalian ribosomal protein L13a, whereby it acts as an antiviral agent. We found that L13a is released from the 60S ribosomal subunit in response to infection by respiratory syncytial virus (RSV), an RNA virus of the Pneumovirus genus and a serious lung pathogen. Unexpectedly, the growth of RSV was highly enhanced in L13a-knocked-down cells of various lineages as well as in L13a knockout macrophages from mice. In all L13a-deficient cells tested, translation of RSV matrix (M) protein was specifically stimulated, as judged by a greater abundance of M protein and greater association of the M mRNA with polyribosomes, while general translation was unaffected. In silico RNA folding analysis and translational reporter assays revealed a putative hairpin in the 3′untranslated region (UTR) of M mRNA with significant structural similarity to the cellular GAIT (gamma-activated inhibitor of translation) RNA hairpin, previously shown to be responsible for assembling a large, L13a-containing ribonucleoprotein complex that promoted translational silencing in gamma interferon (IFN-γ)-activated myeloid cells. However, RNA-protein interaction studies revealed that this complex, which we named VAIT (respiratory syncytial virus-activated inhibitor of translation) is functionally different from the GAIT complex. VAIT is the first report of an extraribosomal L13a-mediated, IFN-γ-independent innate antiviral complex triggered in response to virus infection. We provide a model in which the VAIT complex strongly hinders RSV replication by inhibiting the translation of the rate-limiting viral M protein, which is a new paradigm in antiviral defense. IMPORTANCE The innate immune mechanisms of host cells are diverse in nature and act as a broad-spectrum cellular defense against viruses. Here, we report a novel innate immune mechanism functioning against respiratory syncytial virus (RSV), in which the cellular ribosomal

  5. Flight Test of an L(sub 1) Adaptive Controller on the NASA AirSTAR Flight Test Vehicle

    NASA Technical Reports Server (NTRS)

    Gregory, Irene M.; Xargay, Enric; Cao, Chengyu; Hovakimyan, Naira

    2010-01-01

    This paper presents results of a flight test of the L-1 adaptive control architecture designed to directly compensate for significant uncertain cross-coupling in nonlinear systems. The flight test was conducted on the subscale turbine powered Generic Transport Model that is an integral part of the Airborne Subscale Transport Aircraft Research system at the NASA Langley Research Center. The results presented are for piloted tasks performed during the flight test.

  6. An Ultrasonic Contactless Sensor for Breathing Monitoring

    PubMed Central

    Arlotto, Philippe; Grimaldi, Michel; Naeck, Roomila; Ginoux, Jean-Marc

    2014-01-01

    The monitoring of human breathing activity during a long period has multiple fundamental applications in medicine. In breathing sleep disorders such as apnea, the diagnosis is based on events during which the person stops breathing for several periods during sleep. In polysomnography, the standard for sleep disordered breathing analysis, chest movement and airflow are used to monitor the respiratory activity. However, this method has serious drawbacks. Indeed, as the subject should sleep overnight in a laboratory and because of sensors being in direct contact with him, artifacts modifying sleep quality are often observed. This work investigates an analysis of the viability of an ultrasonic device to quantify the breathing activity, without contact and without any perception by the subject. Based on a low power ultrasonic active source and transducer, the device measures the frequency shift produced by the velocity difference between the exhaled air flow and the ambient environment, i.e., the Doppler effect. After acquisition and digitization, a specific signal processing is applied to separate the effects of breath from those due to subject movements from the Doppler signal. The distance between the source and the sensor, about 50 cm, and the use of ultrasound frequency well above audible frequencies, 40 kHz, allow monitoring the breathing activity without any perception by the subject, and therefore without any modification of the sleep quality which is very important for sleep disorders diagnostic applications. This work is patented (patent pending 2013-7-31 number FR.13/57569). PMID:25140632

  7. Generation of C3- and C2-deuterated L-lactic acid by human erythrocytes exposed to D-[1-13C]glucose, D-[2-13C]glucose and D-[6-13C]glucose in the presence of D2O.

    PubMed

    Malaisse, W J; Biesemans, M; Willem, R

    1994-05-01

    1. The generation of C2- and C3-deuterated L-lactate was monitored by 13C NMR in human erythrocytes exposed to D-[1-13C]glucose, D-[2-13C]glucose or D-[6-13C]glucose and incubated in a medium prepared in D2O. 2. The results suggested that the deuteration of the C1 of D-fructose 6-phosphate in the phosphoglucoisomerase reaction, the deuteration of the C1 of D-glyceraldehyde-3-phosphate in the sequence of reactions catalyzed by triose phosphate isomerase and aldolase and the deuteration of the C3 of pyruvate in the reaction catalyzed by pyruvate kinase were all lower than expected from equilibration with D2O. 3. Moreover, about 40% of the molecules of pyruvate generated by glycolysis apparently underwent deuteration on their C3 during interconversion of the 2-keto acid and L-alanine in the reaction catalyzed by glutamate-pyruvate transaminase. 4. The occurrence of the latter process was also documented in cells exposed to exogenous [3-13C]pyruvate. 5. This methodological approach is proposed to provide a new tool to assess in intact cells the extent of back-and-forth interconversion of selected metabolic intermediates.

  8. 6. "TEST STAND NO. 13, RETAINING WALLS & APRON, SECTIONS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. "TEST STAND NO. 1-3, RETAINING WALLS & APRON, SECTIONS & ELEVATIONS." Specifications No. OC11-50-10; Drawing No. 60-09-06; no sheet number within title block. D.O. SERIES 1109/20, Rev. B. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract DA-04-353 Eng. 177, Rev. B; Date: 26 Dec. 1951. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-3, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  9. 46 CFR 197.456 - Breathing supply hoses.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Breathing supply hoses. 197.456 Section 197.456 Shipping....456 Breathing supply hoses. (a) The diving supervisor shall insure that— (1) Each breathing supply....5 times its maximum working pressure; (2) Each breathing supply hose assembly, prior to being placed...

  10. Afternoon serum-melatonin in sleep disordered breathing.

    PubMed

    Ulfberg, J; Micic, S; Strøm, J

    1998-08-01

    To study afternoon serum-melatonin values in patients with sleep disordered breathing. Melatonin has a strong circadian rhythm with high values during the night-time and low values in the afternoon. Sleep disordered breathing may change the circadian rhythm of melatonin which may have diagnostic implications. The Sleep Laboratory, The Department of Internal Medicine, Avesta Hospital, Sweden, and the Department of Anaesthesiology, Glostrup University Hospital, Copenhagen, Denmark. We examined 60 consecutive patients admitted for sleep disordered breathing and 10 healthy non snoring controls. The patients underwent a sleep apnoea screening test having a specificity of 100% for the obstructive sleep apnoea syndrome (OSAS) using a combination of static charge sensitive bed and oximetry. Obstructive sleep apnoea syndrome was found in 49 patients, eight patients had borderline sleep disordered breathing (BSDB) and three patients were excluded due to interfering disease. Patients and controls had an afternoon determination of serum-melatonin. The Epworth Sleepiness Scale was used to score day-time sleepiness. In comparison with normal controls patients suffering from OSAS had significantly higher serum-melatonin levels in the afternoon. However, as a diagnostic test for OSAS in patients with sleep disordered breathing serum-melatonin showed a low sensitivity but a high specificity. The results indicate that breathing disorders during sleep in general affect pineal function. Sleep disordered breathing seems to disturb pineal function. Determination of afternoon serum-melatonin alone or together with a scoring of daytime sleepiness does not identify OSAS-patients in a heterogeneous population of patients complaining of heavy snoring and excessive daytime sleepiness.

  11. 21 CFR 1210.13 - Tuberculin test.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Tuberculin test. 1210.13 Section 1210.13 Food and... IMPORT MILK ACT Inspection and Testing § 1210.13 Tuberculin test. (a) Except as provided in § 1210.27 any... United States shall be free from tuberculosis, as determined by a tuberculin test applied by an official...

  12. Hydrogen breath test for the diagnosis of lactose intolerance, is the routine sugar load the best one?

    PubMed Central

    Argnani, Fiorenza; Camillo, Mauro Di; Marinaro, Vanessa; Foglietta, Tiziana; Avallone, Veronica; Cannella, Carlo; Vernia, Piero

    2008-01-01

    AIM: To evaluate the prevalence of lactose intolerance (LI) following a load of 12.5 g in patients diagnosed as high-grade malabsorbers using the hydrogen breath test (HBT)-25. METHODS: Ninety patients showing high-grade malabsorption at HBT-25 were submitted to a second HBT with a lactose load of 12.5 g. Peak hydrogen production, area under the curve of hydrogen excretion and occurrence of symptoms were recorded. RESULTS: Only 16 patients (17.77%) with positive HBT-25 proved positive at HBT-12.5. Hydrogen production was lower as compared to HBT-25 (peak value 21.55 parts per million (ppm) ± 29.54 SD vs 99.43 ppm ± 40.01 SD; P < 0.001). Symptoms were present in only 13 patients. The absence of symptoms during the high-dose test has a high negative predictive value (0.84) for a negative low-dose test. The presence of symptoms during the first test was not useful for predicting a positive low-dose test (positive predictive value 0.06-0.31). CONCLUSION: Most patients with a positive HBT-25 normally absorb a lower dose of lactose and a strict lactose restriction on the basis of a “standard” HBT is, in most instances, unnecessary. Thus, the 25 g lactose tolerance test should probably be substituted by the 12.5 g test in the diagnosis of LI, and in providing dietary guidelines to patients with suspected lactose malabsorption/intolerance. PMID:18985811

  13. Hydrogen breath test for the diagnosis of lactose intolerance, is the routine sugar load the best one?

    PubMed

    Argnani, Fiorenza; Di Camillo, Mauro; Marinaro, Vanessa; Foglietta, Tiziana; Avallone, Veronica; Cannella, Carlo; Vernia, Piero

    2008-10-28

    To evaluate the prevalence of lactose intolerance (LI) following a load of 12.5 g in patients diagnosed as high-grade malabsorbers using the hydrogen breath test (HBT)-25. Ninety patients showing high-grade malabsorption at HBT-25 were submitted to a second HBT with a lactose load of 12.5 g. Peak hydrogen production, area under the curve of hydrogen excretion and occurrence of symptoms were recorded. Only 16 patients (17.77%) with positive HBT-25 proved positive at HBT-12.5. Hydrogen production was lower as compared to HBT-25 (peak value 21.55 parts per million (ppm) +/- 29.54 SD vs 99.43 ppm +/- 40.01 SD; P < 0.001). Symptoms were present in only 13 patients. The absence of symptoms during the high-dose test has a high negative predictive value (0.84) for a negative low-dose test. The presence of symptoms during the first test was not useful for predicting a positive low-dose test (positive predictive value 0.06-0.31). Most patients with a positive HBT-25 normally absorb a lower dose of lactose and a strict lactose restriction on the basis of a "standard" HBT is, in most instances, unnecessary. Thus, the 25 g lactose tolerance test should probably be substituted by the 12.5 g test in the diagnosis of LI, and in providing dietary guidelines to patients with suspected lactose malabsorption/intolerance.

  14. Controlled breathing protocols probe human autonomic cardiovascular rhythms

    NASA Technical Reports Server (NTRS)

    Cooke, W. H.; Cox, J. F.; Diedrich, A. M.; Taylor, J. A.; Beightol, L. A.; Ames, J. E. 4th; Hoag, J. B.; Seidel, H.; Eckberg, D. L.

    1998-01-01

    The purpose of this study was to determine how breathing protocols requiring varying degrees of control affect cardiovascular dynamics. We measured inspiratory volume, end-tidal CO2, R-R interval, and arterial pressure spectral power in 10 volunteers who followed the following 5 breathing protocols: 1) uncontrolled breathing for 5 min; 2) stepwise frequency breathing (at 0.3, 0.25, 0.2, 0.15, 0.1, and 0.05 Hz for 2 min each); 3) stepwise frequency breathing as above, but with prescribed tidal volumes; 4) random-frequency breathing (approximately 0.5-0.05 Hz) for 6 min; and 5) fixed-frequency breathing (0.25 Hz) for 5 min. During stepwise breathing, R-R interval and arterial pressure spectral power increased as breathing frequency decreased. Control of inspired volume reduced R-R interval spectral power during 0.1 Hz breathing (P < 0.05). Stepwise and random-breathing protocols yielded comparable coherence and transfer functions between respiration and R-R intervals and systolic pressure and R-R intervals. Random- and fixed-frequency breathing reduced end-tidal CO2 modestly (P < 0.05). Our data suggest that stringent tidal volume control attenuates low-frequency R-R interval oscillations and that fixed- and random-rate breathing may decrease CO2 chemoreceptor stimulation. We conclude that autonomic rhythms measured during different breathing protocols have much in common but that a stepwise protocol without stringent control of inspired volume may allow for the most efficient assessment of short-term respiratory-mediated autonomic oscillations.

  15. Breath analysis in disease diagnosis: methodological considerations and applications.

    PubMed

    Lourenço, Célia; Turner, Claire

    2014-06-20

    Breath analysis is a promising field with great potential for non-invasive diagnosis of a number of disease states. Analysis of the concentrations of volatile organic compounds (VOCs) in breath with an acceptable accuracy are assessed by means of using analytical techniques with high sensitivity, accuracy, precision, low response time, and low detection limit, which are desirable characteristics for the detection of VOCs in human breath. "Breath fingerprinting", indicative of a specific clinical status, relies on the use of multivariate statistics methods with powerful in-built algorithms. The need for standardisation of sample collection and analysis is the main issue concerning breath analysis, blocking the introduction of breath tests into clinical practice. This review describes recent scientific developments in basic research and clinical applications, namely issues concerning sampling and biochemistry, highlighting the diagnostic potential of breath analysis for disease diagnosis. Several considerations that need to be taken into account in breath analysis are documented here, including the growing need for metabolomics to deal with breath profiles.

  16. No radiation protection reasons for restrictions on 14C urea breath tests in children.

    PubMed

    Gunnarsson, M; Leide-Svegborn, S; Stenström, K; Skog, G; Nilsson, L-E; Hellborg, R; Mattsson, S

    2002-12-01

    Traditional (14)C urea breath tests are normally not used for younger children because the radiation exposure is unknown. High sensitivity accelerator mass spectrometry and an ultra-low amount (440 Bq) of (14)C urea were therefore used both to diagnose Helicobacter pylori (HP) infection in seven children, aged 3-6 years, and to make radiation dose estimates. The activity used was 125 times lower than the amount normally used for older children and 250 times lower than that used for adults. Results were compared with previously reported biokinetic and dosimetric data for adults and older children aged 7-14 years. (14)C activity concentrations in urine and exhaled air per unit administered activity for younger children (3-6 years) correspond well with those for older children (7-14 years). For a child aged 3-6 years who is HP negative, the urinary bladder wall receives the highest absorbed dose, 0.3 mGy MBq(-1). The effective dose is 0.1 mSv MBq(-1) for the 3-year-old child and 0.07 mSv MBq(-1) for the 6-year-old child. For two children, the 10 min and 20 min post-(14)C administration samples of exhaled air showed a significantly higher amount of (14)C activity than for the rest of the children, that is 6% and 19% of administered activity exhaled per hour compared with 0.3-0.9% (mean 0.5%) of administered activity exhaled per hour indicating that these two children that is were HP positive. For a 3-year-old HP positive child, absorbed dose to the urinary bladder wall was 0.3 mGy MBq(-1) and effective dose per unit of administered activity was 0.4 mSv MBq(-1). Using 55 kBq, which is a normal amount for older children when liquid scintillation counters are used for measurement, the effective dose will be approximately 6 micro Sv to a 3-year-old HP negative child and 20 microSv to a HP positive child. Thus there is no reason for restrictions on performing a normal (14)C urea breath test, even on young children.

  17. Comparison of breath testing with fructose and high fructose corn syrups in health and IBS

    PubMed Central

    Skoog, S. M.; Bharucha, A. E.; Zinsmeister, A. R.

    2008-01-01

    Although incomplete fructose absorption has been implicated to cause gastrointestinal symptoms, foods containing high fructose corn syrup (HFCS) contain glucose. Glucose increases fructose absorption in healthy subjects. Our hypothesis was that fructose intolerance is less prevalent after HFCS consumption compared to fructose alone in healthy subjects and irritable bowel syndrome (IBS). Breath hydrogen levels and gastrointestinal symptoms were assessed after 40 g of fructose (12% solution) prepared either in water or as HFCS, administered in double-blind randomized order on 2 days in 20 healthy subjects and 30 patients with IBS. Gastrointestinal symptoms were recorded on 100-mm Visual Analogue Scales. Breath hydrogen excretion was more frequently abnormal (P < 0.01) after fructose (68%) than HFCS (26%) in controls and patients. Fructose intolerance (i.e. abnormal breath test and symptoms) was more prevalent after fructose than HFCS in healthy subjects (25% vs 0%, P = 0.002) and patients (40% vs 7%, P = 0.062). Scores for several symptoms (e.g. bloating r = 0.35) were correlated (P ≤ 0.01) to peak breath hydrogen excretion after fructose but not HFCS; in the fructose group, this association did not differ between healthy subjects and patients. Symptoms were not significantly different after fructose compared to HFCS. Fructose intolerance is more prevalent with fructose alone than with HFCS in health and in IBS. The prevalence of fructose intolerance is not significantly different between health and IBS. Current methods for identifying fructose intolerance should be modified to more closely reproduce fructose ingestion in daily life. PMID:18221251

  18. Comparison of breath testing with fructose and high fructose corn syrups in health and IBS.

    PubMed

    Skoog, S M; Bharucha, A E; Zinsmeister, A R

    2008-05-01

    Although incomplete fructose absorption has been implicated to cause gastrointestinal symptoms, foods containing high fructose corn syrup (HFCS) contain glucose. Glucose increases fructose absorption in healthy subjects. Our hypothesis was that fructose intolerance is less prevalent after HFCS consumption compared to fructose alone in healthy subjects and irritable bowel syndrome (IBS). Breath hydrogen levels and gastrointestinal symptoms were assessed after 40 g of fructose (12% solution) prepared either in water or as HFCS, administered in double-blind randomized order on 2 days in 20 healthy subjects and 30 patients with IBS. Gastrointestinal symptoms were recorded on 100-mm Visual Analogue Scales. Breath hydrogen excretion was more frequently abnormal (P < 0.01) after fructose (68%) than HFCS (26%) in controls and patients. Fructose intolerance (i.e. abnormal breath test and symptoms) was more prevalent after fructose than HFCS in healthy subjects (25% vs. 0%, P = 0.002) and patients (40% vs. 7%, P = 0.062). Scores for several symptoms (e.g. bloating r = 0.35) were correlated (P < or = 0.01) to peak breath hydrogen excretion after fructose but not HFCS; in the fructose group, this association did not differ between healthy subjects and patients. Symptoms were not significantly different after fructose compared to HFCS. Fructose intolerance is more prevalent with fructose alone than with HFCS in health and in IBS. The prevalence of fructose intolerance is not significantly different between health and IBS. Current methods for identifying fructose intolerance should be modified to more closely reproduce fructose ingestion in daily life.

  19. Workplace Breathing Rates: Defining Anticipated Values and Ranges for Respirator Certification Testing

    DTIC Science & Technology

    2004-09-01

    Test participants cleared heavy, wet snow with either a shovel or an electric snow thrower in random order, with 10- to 15-minute rest periods between...automated snow thrower . Using the average subject population weight of 85.7 kg, estimated Po2 in L-min-l would be about 1.71 L-min-’ for shoveling and 0.72

  20. 16 CFR 1212.13 - Certification tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Certification tests. 1212.13 Section 1212.13... STANDARD FOR MULTI-PURPOSE LIGHTERS Certification Requirements § 1212.13 Certification tests. (a) General... include: (A) Qualification tests, which must be performed on surrogates of each model of multi-purpose...

  1. 21 CFR 1210.13 - Tuberculin test.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... IMPORT MILK ACT Inspection and Testing § 1210.13 Tuberculin test. (a) Except as provided in § 1210.27 any and all animals in herds producing milk or cream which is to be shipped or transported raw into the... any event, shall have been made within 1 year previous to the time of the importation. All animals...

  2. 3D late gadolinium enhancement in a single prolonged breath-hold using supplemental oxygenation and hyperventilation.

    PubMed

    Roujol, Sébastien; Basha, Tamer A; Akçakaya, Mehmet; Foppa, Murilo; Chan, Raymond H; Kissinger, Kraig V; Goddu, Beth; Berg, Sophie; Manning, Warren J; Nezafat, Reza

    2014-09-01

    To evaluate the feasibility of three-dimensional (3D) single breath-hold late gadolinium enhancement (LGE) of the left ventricle (LV) using supplemental oxygen and hyperventilation and compressed-sensing acceleration. Breath-hold metrics [breath-hold duration, diaphragmatic/LV position drift, and maximum variation of R wave to R wave (RR) interval] without and with supplemental oxygen and hyperventilation were assessed in healthy adult subjects using a real-time single shot acquisition. Ten healthy subjects and 13 patients then underwent assessment of the proposed 3D breath-hold LGE acquisition (field of view = 320 × 320 × 100 mm(3) , resolution = 1.6 × 1.6 × 5.0 mm(3) , acceleration rate of 4) and a free-breathing acquisition with right hemidiaphragm navigator (NAV) respiratory gating. Semiquantitative grading of overall image quality, motion artifact, myocardial nulling, and diagnostic value was performed by consensus of two blinded observers. Supplemental oxygenation and hyperventilation increased the breath-hold duration (35 ± 11 s to 58 ± 21 s; P < 0.0125) without significant impact on diaphragmatic/LV position drift or maximum variation of RR interval (both P > 0.01). LGE images were of similar quality when compared with free-breathing acquisitions, but with reduced total scan time (85 ± 22 s to 35 ± 6 s; P < 0.001). Supplemental oxygenation and hyperventilation allow for prolonged breath-holding and enable single breath-hold 3D accelerated LGE with similar image quality as free breathing with NAV. Copyright © 2013 Wiley Periodicals, Inc.

  3. Variability in the blood/breath alcohol ratio and implications for evidentiary purposes.

    PubMed

    Jaffe, Dena H; Siman-Tov, Maya; Gopher, Asher; Peleg, Kobi

    2013-09-01

    The breath analyzer is an indispensable tool for identifying alcohol levels among drivers. While numerous studies have shown high correlations between blood and breath alcohol concentrations, most are limited by the study design. This study seeks to assess this relationship by minimizing potential measurement bias, document time from alcohol consumption to testing, and adjusting for potential confounders. A blinded study was performed using conditions closely resembling those in the field. The Draeger 7110 MKIII IL breath analyzer was used to assess breath alcohol concentrations (BrAC). Participants were 61 healthy volunteers aged 21-37 years with body mass index ≤30 and no history of alcoholism. A total of 242 valid blood/breath tests were performed in four test sets. The study results showed a high correlation coefficient between BrAC and blood alcohol concentration (BAC) levels (r = 0.983) with high sensitivity (97%) and specificity (93%). This strong association between the breath analyzer and BAC persisted even after adjustment for various stages of alcohol absorption. These results illustrate the high diagnostic sensitivity of the breath analyzer in field-tested conditions. © 2013 American Academy of Forensic Sciences.

  4. Soluble β-(1,3)-glucans enhance LPS-induced response in the monocyte activation test, but inhibit LPS-mediated febrile response in rabbits: Implications for pyrogenicity tests.

    PubMed

    Pardo-Ruiz, Zenia; Menéndez-Sardiñas, Dalia E; Pacios-Michelena, Anabel; Gabilondo-Ramírez, Tatiana; Montero-Alejo, Vivian; Perdomo-Morales, Rolando

    2016-01-01

    In the present study, we aimed to determine the influence of β-(1,3)-d-glucans on the LPS-induced pro-inflammatory cytokine response in the Monocyte Activation Test (MAT) for pyrogens, and on the LPS-induced febrile response in the Rabbit Pyrogen Test (RPT), thus evaluating the resulting effect in the outcome of each test. It was found that β-(1,3)-d-glucans elicited the production of pro-inflammatory cytokines IL-1β, IL-6 and TNF-α, also known as endogenous pyrogens, but not enough to classify them as pyrogenic according to MAT. The same β-(1,3)-d-glucans samples were non-pyrogenic by RPT. However, β-(1,3)-d-glucans significantly enhanced the LPS-induced pro-inflammatory cytokines response in MAT, insomuch that samples containing non-pyrogenic concentrations of LPS become pyrogenic. On the other hand, β-(1,3)-d-glucans had no effect on sub-pyrogenic LPS doses in the RPT, but surprisingly, inhibited the LPS-induced febrile response of pyrogenic LPS concentrations. Thus, while β-(1,3)-d-glucans could mask the LPS pyrogenic activity in the RPT, they exerted an overstimulation of pro-inflammatory cytokines in the MAT. Hence, MAT provides higher safety since it evidences an unwanted biological response, which is not completely controlled and is overlooked by the RPT. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. 5. "TEST STAND 13, CONCRETE STRUCTURAL SECTIONS AND DETAILS." Specifications ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. "TEST STAND 1-3, CONCRETE STRUCTURAL SECTIONS AND DETAILS." Specifications No. OC12-50-10; Drawing No. 60-09-06; no sheet number within title block. D.O. SERIES 1109/17, Rev. A. Stamped: AS BUILT; NO CHANGES. Date of Revision A: 11/1/50. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-3, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  6. ASTRONAUT CRIPPEN, ROBERT L. - PILOT - STS-1 - TRAINING - JSC

    NASA Image and Video Library

    1978-03-22

    S79-25007 (13 Dec. 1978) --- Astronaut Robert L. Crippen, pilot for the first space shuttle orbital flight test (STS-1), is assisted by technicians prior to entering a water immersion facility (WIF) during a training session. The zero-gravity familiarization took place in the Johnson Space Center?s training and test center (Building 260). The WIF afford one of two ways to simulate the feeling of weightlessness experienced during space extravehicular activity (EVA), the other being inside aircraft flying a parabolic curve. Crippen will be joined by astronaut John W. Young for the STS-1 flight. Photo credit: NASA

  7. DSS 13 frequency stability tests

    NASA Technical Reports Server (NTRS)

    Otoshi, T. Y.; Franco, M. M.

    1987-01-01

    In a previous article, the results of frequency stability tests at DSS 13 were presented in table form for tau = 1000 s for the test period May 1985 through March 1986. This article is a continuation of that initial report and presents specially selected Allan sigma (square root of variance) plots of each of the subsystem test previously reported. An additional result obtained from tests performed during July 1986 was included for completeness. The Allan sigma plots are useful in that frequency stability information is not only given for tau = 1000 s, but for tau values in the regions of 1, 100, 500, and 2000 s as well.

  8. Effects of Incentive Spirometry on Respiratory Motion in Healthy Subjects Using Cine Breathing Magnetic Resonance Imaging.

    PubMed

    Kotani, Toshiaki; Akazawa, Tsutomu; Sakuma, Tsuyoshi; Nagaya, Shigeyuki; Sonoda, Masaru; Tanaka, Yuji; Katogi, Takehide; Nemoto, Tetsuharu; Minami, Shohei

    2015-06-01

    To investigate the effectiveness of incentive spirometry on respiratory motion in healthy subjects using cine breathing magnetic resonance imaging (MRI). Ten non-smoking healthy subjects without any history of respiratory disease were studied. Subjects were asked to perform pulmonary training using incentive spirometry every day for two weeks. To assess the effectiveness of this training, pulmonary function tests and cine breathing MRI were performed before starting pulmonary training and two weeks after its completion. After training, there were significant improvements in vital capacity (VC) from 3.58±0.8 L to 3.74±0.8 L and in %VC from 107.4±10.8 to 112.1±8.2. Significant changes were observed in the right diaphragm motion, right chest wall motion, and left chest wall motion, which were increased from 55.7±9.6 mm to 63.4±10.2 mm, from 15.6±6.1 mm to 23.4±10.4 mm, and from 16.3±7.6 mm to 22.0±9.8 mm, respectively. Two weeks of training using incentive spirometry provided improvements in pulmonary function and respiratory motion, which suggested that incentive spirometry may be a useful preoperative modality for improving pulmonary function during the perioperative period.

  9. 47 CFR 74.13 - Equipment tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Equipment tests. 74.13 Section 74.13... Services in Part 74 § 74.13 Equipment tests. (a) During the process of construction of any class of radio... equipment tests for the purpose of such adjustments and measurements as may be necessary to assure...

  10. 47 CFR 74.13 - Equipment tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false Equipment tests. 74.13 Section 74.13... Services in Part 74 § 74.13 Equipment tests. (a) During the process of construction of any class of radio... equipment tests for the purpose of such adjustments and measurements as may be necessary to assure...

  11. 47 CFR 74.13 - Equipment tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Equipment tests. 74.13 Section 74.13... Services in Part 74 § 74.13 Equipment tests. (a) During the process of construction of any class of radio... equipment tests for the purpose of such adjustments and measurements as may be necessary to assure...

  12. The saponin monomer of dwarf lilyturf tuber, DT-13, reduces L-type calcium currents during hypoxia in adult rat ventricular myocytes.

    PubMed

    Tao, Jin; Wang, Hongyi; Zhou, Hong; Li, Shengnan

    2005-10-28

    The saponin monomer 13 of dwarf lilyturf tuber (DT-13), one of the saponin monomers of dwarf lilyturf tuber, has been found to have potent cardioprotective effects. In order to investigate the effects of DT-13 on L-type calcium currents (I(Ca,L)), exploring the mechanisms of DT-13's cardioprotective effects in the condition of pathophysiology, we directly measured the I(Ca,L) during hypoxia in the adult rat cardiac myocytes exposed to DT-13 using standard whole-cell patch-clamp recording technique. Our previous results showed that DT-13 exerted decreasing effects on the I(Ca,L) of the single adult rat cardiac myocytes. In the condition of hypoxia, the current density was inhibited by about 29% after exposure of the cells to DT-13 (0.1 micromol L(-1)) for 10 min, from 6.96+/-1.05 pA/pF to 4.38+/-0.35 pA/pF (n=5, P<0.05). This I(Ca,L)-inhibiting action of DT-13 was concentration-dependent and showed no frequency-dependence. DT-13 up-shifted the current-voltage (I-V) curve. Steady-state activation of I(Ca,L) was not affected markedly, and the half activation potential (V(0.5)) in the presence of DT-13 (0.1 micromol L(-1)) was also not significantly different. DT-13 at 0.1 micromol L(-1) markedly accelerated the voltage-dependent steady-state inactivation of calcium current and shifted the steady-state inactivation curve of I(Ca,L) to the left. In combination with previous reports, these results suggest that there might be a close relationship between the cardioprotective effects of DT-13 and L-type calcium channels in the condition of hypoxia.

  13. How and When Do Insects Rely on Endogenous Protein and Lipid Resources during Lethal Bouts of Starvation? A New Application for 13C-Breath testing

    PubMed Central

    McCue, Marshall D.; Guzman, R. Marena; Passement, Celeste A.; Davidowitz, Goggy

    2015-01-01

    Most of our understanding about the physiology of fasting and starvation comes from studies of vertebrates; however, for ethical reasons, studies that monitor vertebrates through the lethal endpoint are scant. Insects are convenient models to characterize the comparative strategies used to cope with starvation because they have diverse life histories and have evolved under the omnipresent challenge of food limitation. Moreover, we can study the physiology of starvation through its natural endpoint. In this study we raised populations of five species of insects (adult grasshoppers, crickets, cockroaches, and larval beetles and moths) on diets labeled with either 13C-palmitic acid or 13C-leucine to isotopically enrich the lipids or the proteins in their bodies, respectively. The insects were allowed to become postabsorptive and then starved. We periodically measured the δ13C of the exhaled breath to characterize how each species adjusted their reliance on endogenous lipids and proteins as energy sources. We found that starving insects employ a wide range of strategies for regulating lipid and protein oxidation. All of the insects except for the beetle larvae were capable of sharply reducing reliance on protein oxidation; however, this protein sparing strategy was usually unsustainable during the entire starvation period. All insects increased their reliance on lipid oxidation, but while some species (grasshoppers, cockroaches, and beetle larvae) were still relying extensively on lipids at the time of death, other species (crickets and moth larvae) allowed rates of lipid oxidation to return to prestarvation levels. Although lipids and proteins are critical metabolic fuels for both vertebrates and insects, insects apparently exhibit a much wider range of strategies for rationing these limited resources during starvation. PMID:26465334

  14. How and When Do Insects Rely on Endogenous Protein and Lipid Resources during Lethal Bouts of Starvation? A New Application for 13C-Breath testing.

    PubMed

    McCue, Marshall D; Guzman, R Marena; Passement, Celeste A; Davidowitz, Goggy

    2015-01-01

    Most of our understanding about the physiology of fasting and starvation comes from studies of vertebrates; however, for ethical reasons, studies that monitor vertebrates through the lethal endpoint are scant. Insects are convenient models to characterize the comparative strategies used to cope with starvation because they have diverse life histories and have evolved under the omnipresent challenge of food limitation. Moreover, we can study the physiology of starvation through its natural endpoint. In this study we raised populations of five species of insects (adult grasshoppers, crickets, cockroaches, and larval beetles and moths) on diets labeled with either 13C-palmitic acid or 13C-leucine to isotopically enrich the lipids or the proteins in their bodies, respectively. The insects were allowed to become postabsorptive and then starved. We periodically measured the δ13C of the exhaled breath to characterize how each species adjusted their reliance on endogenous lipids and proteins as energy sources. We found that starving insects employ a wide range of strategies for regulating lipid and protein oxidation. All of the insects except for the beetle larvae were capable of sharply reducing reliance on protein oxidation; however, this protein sparing strategy was usually unsustainable during the entire starvation period. All insects increased their reliance on lipid oxidation, but while some species (grasshoppers, cockroaches, and beetle larvae) were still relying extensively on lipids at the time of death, other species (crickets and moth larvae) allowed rates of lipid oxidation to return to prestarvation levels. Although lipids and proteins are critical metabolic fuels for both vertebrates and insects, insects apparently exhibit a much wider range of strategies for rationing these limited resources during starvation.

  15. Antimicrobial effects of GL13K peptide coatings on S. mutans and L. casei

    NASA Astrophysics Data System (ADS)

    Schnitt, Rebecca Ann

    Background: Enamel breakdown around orthodontic brackets, so-called "white spot lesions", is the most common complication of orthodontic treatment. White spot lesions are caused by bacteria such as Streptococci and Lactobacilli, whose acidic byproducts cause demineralization of enamel crystals. Aims: The aim of this project was to develop an antimicrobial peptide coating for titanium alloy that is capable of killing acidogenic bacteria, specifically Streptococcus mutans and Lactobacillus casei. The long-term goal is to create an antimicrobial-coated orthodontic bracket with the ability to reduce or prevent the formation of white spot lesions in orthodontic patients thereby improving clinical outcomes. Methods: First, an alkaline etching method with NaOH was established to allow effective coating of titanium discs with GL13K, an antimicrobial peptide derived from human saliva. Coatings were verified by contact angle measures, and treated discs were characterized using scanning electron microscopy. Secondly, GL13K coatings were tested against hydrolytic, proteolytic and mechanical challenges to ensure robust coatings. Third, a series of qualitative and quantitative microbiology experiments were performed to determine the effects of GL13K--L and GL13K--D on S. mutans and L. casei, both in solution and coated on titanium. Results: GL13K-coated discs were stable after two weeks of challenges. GL13K--D was effective at killing S. mutans in vitro at low doses. GL13K--D also demonstrated a bactericidal effect on L. casei, however, in contrast to S. mutans, the effect on L. casei was not statistically significant. Conclusion: GL13K--D is a promising candidate for antimicrobial therapy with possible applications for prevention of white spot lesions in orthodontics.

  16. Evaluation of portable breath test devices for screening suspected drunken drivers by police in Hennepin County, Minnesota

    DOT National Transportation Integrated Search

    1974-06-01

    This evaluation report examines use in the field of portable breath test (PBT) devices by police in Hennepin County, Minnesota. Thirteen Brog-Warner J2 and J2A-200 "ALERT" devices were deployed by seven enforcement agencies. This report is presented ...

  17. Extraribosomal l13a is a specific innate immune factor for antiviral defense.

    PubMed

    Mazumder, Barsanjit; Poddar, Darshana; Basu, Abhijit; Kour, Ravinder; Verbovetskaya, Valentina; Barik, Sailen

    2014-08-01

    We report a novel extraribosomal innate immune function of mammalian ribosomal protein L13a, whereby it acts as an antiviral agent. We found that L13a is released from the 60S ribosomal subunit in response to infection by respiratory syncytial virus (RSV), an RNA virus of the Pneumovirus genus and a serious lung pathogen. Unexpectedly, the growth of RSV was highly enhanced in L13a-knocked-down cells of various lineages as well as in L13a knockout macrophages from mice. In all L13a-deficient cells tested, translation of RSV matrix (M) protein was specifically stimulated, as judged by a greater abundance of M protein and greater association of the M mRNA with polyribosomes, while general translation was unaffected. In silico RNA folding analysis and translational reporter assays revealed a putative hairpin in the 3'untranslated region (UTR) of M mRNA with significant structural similarity to the cellular GAIT (gamma-activated inhibitor of translation) RNA hairpin, previously shown to be responsible for assembling a large, L13a-containing ribonucleoprotein complex that promoted translational silencing in gamma interferon (IFN-γ)-activated myeloid cells. However, RNA-protein interaction studies revealed that this complex, which we named VAIT (respiratory syncytial virus-activated inhibitor of translation) is functionally different from the GAIT complex. VAIT is the first report of an extraribosomal L13a-mediated, IFN-γ-independent innate antiviral complex triggered in response to virus infection. We provide a model in which the VAIT complex strongly hinders RSV replication by inhibiting the translation of the rate-limiting viral M protein, which is a new paradigm in antiviral defense. The innate immune mechanisms of host cells are diverse in nature and act as a broad-spectrum cellular defense against viruses. Here, we report a novel innate immune mechanism functioning against respiratory syncytial virus (RSV), in which the cellular ribosomal protein L13a is released

  18. Effect of Time-of-Flight Information on PET/MR Reconstruction Artifacts: Comparison of Free-breathing versus Breath-hold MR-based Attenuation Correction.

    PubMed

    Delso, Gaspar; Khalighi, Mohammed; Ter Voert, Edwin; Barbosa, Felipe; Sekine, Tetsuro; Hüllner, Martin; Veit-Haibach, Patrick

    2017-01-01

    Purpose To evaluate the magnitude and anatomic extent of the artifacts introduced on positron emission tomographic (PET)/magnetic resonance (MR) images by respiratory state mismatch in the attenuation map. Materials and Methods The method was tested on 14 patients referred for an oncologic examination who underwent PET/MR imaging. The acquisition included standard PET and MR series for each patient, and an additional attenuation correction series was acquired by using breath hold. PET data were reconstructed with and without time-of-flight (TOF) information, first by using the standard free-breathing attenuation map and then again by using the additional breath-hold map. Two-tailed paired t testing and linear regression with 0 intercept was performed on TOF versus non-TOF and free-breathing versus breath-hold data for all detected lesions. Results Fluorodeoxyglucose-avid lesions were found in eight of the 14 patients included in the study. The uptake differences (maximum standardized uptake values) between PET reconstructions with free-breathing versus breath-hold attenuation ranged, for non-TOF reconstructions, from -18% to 26%. The corresponding TOF reconstructions yielded differences from -15% to 18%. Conclusion TOF information was shown to reduce the artifacts caused at PET/MR by respiratory mismatch between emission and attenuation data. © RSNA, 2016 Online supplemental material is available for this article.

  19. Breath Analysis in Disease Diagnosis: Methodological Considerations and Applications

    PubMed Central

    Lourenço, Célia; Turner, Claire

    2014-01-01

    Breath analysis is a promising field with great potential for non-invasive diagnosis of a number of disease states. Analysis of the concentrations of volatile organic compounds (VOCs) in breath with an acceptable accuracy are assessed by means of using analytical techniques with high sensitivity, accuracy, precision, low response time, and low detection limit, which are desirable characteristics for the detection of VOCs in human breath. “Breath fingerprinting”, indicative of a specific clinical status, relies on the use of multivariate statistics methods with powerful in-built algorithms. The need for standardisation of sample collection and analysis is the main issue concerning breath analysis, blocking the introduction of breath tests into clinical practice. This review describes recent scientific developments in basic research and clinical applications, namely issues concerning sampling and biochemistry, highlighting the diagnostic potential of breath analysis for disease diagnosis. Several considerations that need to be taken into account in breath analysis are documented here, including the growing need for metabolomics to deal with breath profiles. PMID:24957037

  20. Design and Validation of a Breathing Detection System for Scuba Divers.

    PubMed

    Altepe, Corentin; Egi, S Murat; Ozyigit, Tamer; Sinoplu, D Ruzgar; Marroni, Alessandro; Pierleoni, Paola

    2017-06-09

    Drowning is the major cause of death in self-contained underwater breathing apparatus (SCUBA) diving. This study proposes an embedded system with a live and light-weight algorithm which detects the breathing of divers through the analysis of the intermediate pressure (IP) signal of the SCUBA regulator. A system composed mainly of two pressure sensors and a low-power microcontroller was designed and programmed to record the pressure sensors signals and provide alarms in absence of breathing. An algorithm was developed to analyze the signals and identify inhalation events of the diver. A waterproof case was built to accommodate the system and was tested up to a depth of 25 m in a pressure chamber. To validate the system in the real environment, a series of dives with two different types of workload requiring different ranges of breathing frequencies were planned. Eight professional SCUBA divers volunteered to dive with the system to collect their IP data in order to participate to validation trials. The subjects underwent two dives, each of 52 min on average and a maximum depth of 7 m. The algorithm was optimized for the collected dataset and proved a sensitivity of inhalation detection of 97.5% and a total number of 275 false positives (FP) over a total recording time of 13.9 h. The detection algorithm presents a maximum delay of 5.2 s and requires only 800 bytes of random-access memory (RAM). The results were compared against the analysis of video records of the dives by two blinded observers and proved a sensitivity of 97.6% on the data set. The design includes a buzzer to provide audible alarms to accompanying dive buddies which will be triggered in case of degraded health conditions such as near drowning (absence of breathing), hyperventilation (breathing frequency too high) and skip-breathing (breathing frequency too low) measured by the improper breathing frequency. The system also measures the IP at rest before the dive and indicates with flashing light

  1. 42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100 Section 84.100 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.100 Man tests 1...

  2. Use of warrants for breath test refusal : case studies

    DOT National Transportation Integrated Search

    2007-10-01

    This study investigated the use of warrants to obtain blood samples from drivers arrested for alcohol-impaired driving and who refuse to provide breath samples when requested to do so by law enforcement officers. Case studies were conducted in four S...

  3. [Comparative diagnostic value of Helicobacter pylori infection testing methods].

    PubMed

    Girdalidze, A M; Elisabedashvili, G V; Sharvadze, L G; Dzhorbenadze, T A

    2013-12-01

    In 213 patients with gastric and duodenal pathology, including received surgery, comparative estimation of results of Helicobacter pylori (Hp) infection testing with invasive and noninvasive methods, were performed. Material for invasive endoscopic biopsy test (EBT), including rapid urease test (RUT) for rapid Hp identification by determination of urease activity, smear cytology and histology was extracted on endoscopy or intraoperationally. RUT was carried out with the help of URE-HP test kit. Serological test for Hp antibodies IgG and IgA class was performed by IFA using kit ELISA. 13С urea breath test (UBT) was made by determination of 13/12CO2 in breath samples on infrared spectroscope. Based on 5 different methods of Hp infection testing Hp positivity in 172 (80,8%) and Hp negativity in 41 (19,2%) from 213 examined patients was revealed. 13С-UBT revealed the highest diagnostic value (accuracy-97,5%, sensibility-97,0%, specificity-100%) in Hp infection diagnostics. In treatment efficiency control this parameters of 13С-UBT are also much high (96,7%, 90,0% and 100% respectively). In spite of high sensitivity of serological test (100%), it had comparative low specificity (71,0%) with high probability of false positive results in treated patients (antibodies titer to Hp after eradication retains for a long time). Thought, this test may be successfully used only in primary patients and in epidemiological studies. Among three methods of EBT, Hp infection detection with RUT revealed the best results (accuracy-94,8%, sensibility-95,0%, specificity-100%). Correlation of RUT and UBT results and much higher diagnostic value of UBT, necessitate RUT with histological study of stomach body mucosa to perform in patients over 45 year, with prolonged anamnesis and dangerous symptoms of disease. In Hp positive patients correlation of index DOB‰ of breath test with results of RUT was revealed. This can serve the index DOB‰ of 13С-UBT as a marker of Hp infection rate. The

  4. Double blind randomised controlled trial of two different breathing techniques in the management of asthma.

    PubMed

    Slader, C A; Reddel, H K; Spencer, L M; Belousova, E G; Armour, C L; Bosnic-Anticevich, S Z; Thien, F C K; Jenkins, C R

    2006-08-01

    Previous studies have shown that breathing techniques reduce short acting beta(2) agonist use and improve quality of life (QoL) in asthma. The primary aim of this double blind study was to compare the effects of breathing exercises focusing on shallow nasal breathing with those of non-specific upper body exercises on asthma symptoms, QoL, other measures of disease control, and inhaled corticosteroid (ICS) dose. This study also assessed the effect of peak flow monitoring on outcomes in patients using breathing techniques. After a 2 week run in period, 57 subjects were randomised to one of two breathing techniques learned from instructional videos. During the following 30 weeks subjects practised their exercises twice daily and as needed for relief of symptoms. After week 16, two successive ICS downtitration steps were attempted. The primary outcome variables were QoL score and daily symptom score at week 12. Overall there were no clinically important differences between the groups in primary or secondary outcomes at weeks 12 or 28. The QoL score remained unchanged (0.7 at baseline v 0.5 at week 28, p = 0.11 both groups combined), as did lung function and airway responsiveness. However, across both groups, reliever use decreased by 86% (p<0.0001) and ICS dose was reduced by 50% (p<0.0001; p>0.10 between groups). Peak flow monitoring did not have a detrimental effect on asthma outcomes. Breathing techniques may be useful in the management of patients with mild asthma symptoms who use a reliever frequently, but there is no evidence to favour shallow nasal breathing over non-specific upper body exercises.

  5. Breath-holding spells may be associated with maturational delay in myelination of brain stem.

    PubMed

    Vurucu, Sebahattin; Karaoglu, Abdulbaki; Paksu, Sukru M; Oz, Oguzhan; Yaman, Halil; Gulgun, Mustafa; Babacan, Oguzhan; Unay, Bulent; Akin, Ridvan

    2014-02-01

    To evaluate possible contribution of maturational delay of brain stem in the etiology of breath-holding spells in children using brain stem auditory evoked potentials. The study group included children who experienced breath-holding spells. The control group consisted of healthy age- and sex-matched children. Age, gender, type and frequency of spell, hemoglobin, and ferritin levels in study group and brain stem auditory evoked potentials results in both groups were recorded. Study group was statistically compared with control group for brain stem auditory evoked potentials. The mean age of study and control groups was 26.3 ± 14.6 and 28.9 ± 13.9 months, respectively. The III-V and I-V interpeak latencies were significantly prolonged in the study group compared with the control group (2.07 ± 0.2 milliseconds; 1.92 ± 0.13 milliseconds and 4.00 ± 0.27 milliseconds; 3.83 ± 0.19 milliseconds; P = 0.009 and P = 0.03, respectively). At the same time, III-V and I-V interpeak latencies of patients without anemia in the study group compared with those of control group were significantly prolonged (2.09 ± 0.24 milliseconds; 1.92 ± 0.13 milliseconds and 4.04 ± 0.28 milliseconds; 3.83 ± 0.19 milliseconds; P = 0.007 and P = 0.01, respectively). Our results consider that maturational delay in myelination of brain stem may have a role in the etiology of breath-holding spells in children.

  6. 16 CFR 1210.13 - Certification tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Certification tests. 1210.13 Section 1210.13 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY STANDARD FOR CIGARETTE LIGHTERS Certification Requirements § 1210.13 Certification tests. (a) General. As...

  7. 16 CFR 1210.13 - Certification tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Certification tests. 1210.13 Section 1210.13 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY STANDARD FOR CIGARETTE LIGHTERS Certification Requirements § 1210.13 Certification tests. (a) General. As...

  8. Effect of upper costal and costo-diaphragmatic breathing types on electromyographic activity of respiratory muscles.

    PubMed

    Celhay, Isabel; Cordova, Rosa; Miralles, Rodolfo; Meza, Francisco; Erices, Pia; Barrientos, Camilo; Valenzuela, Saúl

    2015-04-01

    To compare electromyographic (EMG) activity in young-adult subjects with different breathing types. This study included 50 healthy male subjects with complete natural dentition, and no history of orofacial pain or craniomandibular-cervical-spinal disorders. Subjects were classified into two groups: upper costal breathing type, and costo-diaphragmatic breathing. Bipolar surface electrodes were located on sternocleidomastoid, diaphragm, external intercostal, and latissimus dorsi muscles. Electromyographic activity was recorded during the following tasks: (1) normal quiet breathing; (2) speaking the word 'Mississippi'; (3) swallowing saliva; and (4) forced deep breathing. Sternocleidomastoid and latissimus dorsi EMG activity was not significantly different between breathing types, whereas diaphragm and external intercostal EMG activity was significantly higher in the upper costal than costo-diaphragmatic breathing type in all tasks (P<0·05; Wilcoxon signed rank-sum test). Diaphragm and external intercostal EMG activity suggests that there could be differences in motor unit recruitment strategies depending on the breathing type.

  9. The Relationship between High Flow Nasal Cannula Flow Rate and Effort of Breathing in Children.

    PubMed

    Weiler, Thomas; Kamerkar, Asavari; Hotz, Justin; Ross, Patrick A; Newth, Christopher J L; Khemani, Robinder G

    2017-10-01

    To use an objective metric of effort of breathing to determine optimal high flow nasal cannula (HFNC) flow rates in children <3 years of age. Single-center prospective trial in a 24-bed pediatric intensive care unit of children <3 years of age on HFNC. We measured the percent change in pressure∙rate product (PRP) (an objective measure of effort of breathing) as a function of weight-indexed flow rates of 0.5, 1.0, 1.5, and 2.0 L/kg/minute. For a subgroup of patients, 2 different HFNC delivery systems (Fisher & Paykel [Auckland, New Zealand] and Vapotherm [Exeter, New Hampshire]) were compared. Twenty-one patients (49 titration episodes) were studied. The most common diagnoses were bronchiolitis and pneumonia. Overall, there was a significant difference in the percent change in PRP from baseline (of 0.5 L/kg/minute) with increasing flow rates for the entire cohort (P < .001) with largest change at 2.0 L/kg/min (-21%). Subgroup analyses showed no significant difference in percent change in PRP from baseline when comparing the 2 different HFNC delivery systems (P = .12). Patients ≤8 kg experienced a larger percent change in PRP as HFNC flow rates were increased (P = .001) than patients >8 kg. The optimal HFNC flow rate to reduce effort of breathing in infants and young children is approximately 1.5-2.0 L/kg/minute with more benefit seen in children ≤8 kg. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Tracking performance with two breathing oxygen concentrations after high altitude rapid decompression

    NASA Technical Reports Server (NTRS)

    Nesthus, Thomas E.; Schiflett, Samuel G.; Oakley, Carolyn J.

    1992-01-01

    Current military aircraft Liquid Oxygen (LOX) systems supply 99.5 pct. gaseous Aviator's Breathing Oxygen (ABO) to aircrew. Newer Molecular Sieve Oxygen Generation Systems (MSOGS) supply breathing gas concentration of 93 to 95 pct. O2. The margin is compared of hypoxia protection afforded by ABO and MSOGS breathing gas after a 5 psi differential rapid decompression (RD) in a hypobaric research chamber. The barometric pressures equivalent to the altitudes of 46000, 52000, 56000, and 60000 ft were achieved from respective base altitudes in 1 to 1.5 s decompressions. During each exposure, subjects remained at the simulated peak altitude breathing either 100 or 94 pct. O2 with positive pressure for 60 s, followed by a rapid descent to 40000 ft. Subjects used the Tactical Life Support System (TLSS) for high altitude protection. Subcritical tracking task performance on the Performance Evaluation Device (PED) provided psychomotor test measures. Overall tracking task performance results showed no differences between the MSOGS breathing O2 concentration of 94 pct. and ABO. Significance RMS error differences were found between the ground level and base altitude trials compared to peak altitude trials. The high positive breathing pressures occurring at the peak altitudes explained the differences.

  11. A chlorate candle/lithium hydroxide personal breathing apparatus

    NASA Technical Reports Server (NTRS)

    Martin, F. E.

    1972-01-01

    A portable coal mine rescue and survival equipment is reported that consists of a chlorate candle with a lithium hydroxide carbon-dioxide absorbent for oxygen generation, a breathing bag and tubing to conduct breathing to and from the man. A plastic hood incorporating a mouth piece for communication provides also eye protection and prevents inhalation through the nose. Manned testing of a prototype system demonstrated the feasibility of this closed circuit no-maintenance breathing apparatus that provides for good voice communication.

  12. Effects of alcohol-based hand hygiene solutions on breath alcohol detection in the emergency department.

    PubMed

    Emerson, Beth L; Whitfill, Travis; Baum, Carl R; Garlin-Kane, Katherine; Santucci, Karen

    2016-12-01

    This study aimed to investigate the effects of alcohol-based hand hygiene solution (ABHS) use by care providers on point-of-care alcohol breath analyzer interpretation under different clinically relevant conditions. Among each test condition (foam vehicle with immediate testing, gel vehicle with immediate testing, allowing hands to dry after the use of ABHS, and donning gloves after the use of ABHS), alcohol was detected in breath at 1 minute after use of ABHS. Because the use of ABHS by individuals administering breath alcohol detection may result in false-positive detection of alcohol, staff using these devices should consider traditional hand hygiene with soap and water. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  13. 47 CFR 74.13 - Equipment tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Equipment tests. 74.13 Section 74.13 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES EXPERIMENTAL RADIO, AUXILIARY, SPECIAL BROADCAST AND OTHER PROGRAM DISTRIBUTIONAL SERVICES General; Rules Applicable to All Services in Part 74 § 74.13 Equipment tests. (...

  14. Activity of Lower Limb Muscles During Squat With and Without Abdominal Drawing-in and Pilates Breathing.

    PubMed

    Barbosa, Alexandre C; Martins, Fábio M; Silva, Angélica F; Coelho, Ana C; Intelangelo, Leonardo; Vieira, Edgar R

    2017-11-01

    Barbosa, AC, Martins, FM, Silva, AF, Coelho, AC, Intelangelo, L, and Vieira, ER. Activity of lower limb muscles during squat with and without abdominal drawing-in and Pilates breathing. J Strength Cond Res 31(11): 3018-3023, 2017-The purpose of this study was to assess the effects of abdominal drawing-in and Pilates breathing on the activity of lower limb muscles during squats. Adults (n = 13, 22 ± 3 years old) with some Pilates experience performed three 60° squats under each of the following conditions in a random order: (I) normal breathing, (II) drawing-in maneuver with normal breathing, and (III) drawing-in maneuver with Pilates breathing. Peak-normalized surface electromyography of the rectus femoris, biceps femoris, gastrocnemius medialis, and tibialis anterior during the knee flexion and extension phases of squat exercises was analyzed. There were significant differences among the conditions during the knee flexion phase for the rectus femoris (p = 0.001), biceps femoris (p = 0.038), and tibialis anterior (p = 0.001), with increasing activation from conditions I to III. For the gastrocnemius medialis, there were significant differences among the conditions during the knee extension phase (p = 0.023), with increased activity under condition I. The rectus and biceps femoris activity was higher during the extension vs. flexion phase under conditions I and II. The tibialis anterior activity was higher during the flexion compared with the extension phase under all conditions, and the medial gastrocnemius activity was higher during the extension phase under condition I. Doing squats with abdominal drawing-in and Pilates breathing resulted in increased rectus, biceps femoris, and tibialis anterior activity during the flexion phase, increasing movement stability during squat exercises.

  15. A study of the methodological and clinical validity of the combined lactulose hydrogen breath test with scintigraphic oro-cecal transit test for diagnosing small intestinal bacterial overgrowth in IBS patients.

    PubMed

    Zhao, J; Zheng, X; Chu, H; Zhao, J; Cong, Y; Fried, M; Fox, M; Dai, N

    2014-06-01

    Small intestinal bacterial overgrowth (SIBO) may be a cause of irritable bowel syndrome (IBS); however, current investigations have important limitations. We aimed to identify clinically relevant diagnostic criteria for SIBO based on lactulose hydrogen breath test (LHBT) alone and combined with scintigraphic measurement of oro-cecal transit (SOCT). Results of LHBT/SOCT investigation from 89 IBS patients and 13 healthy volunteers were included in a systematic analysis of six published criteria for SIBO diagnosis. Clinical relevance of competing criteria was determined by assessing (i) prevalence of SIBO in IBS patients and healthy volunteers (ii) if SIBO diagnosis predicted improvement in IBS symptoms in a prospective, pilot therapeutic trial of a non-absorbable antibiotic (rifaximin 600 mg b.d.) in IBS patients. Reproducibility of SIBO diagnosis by combined LHBT/SOCT was near perfect. A ≥5 ppm H2 increase prior to appearance of cecal contrast was detected in more IBS patients than healthy volunteers (35/89 vs 1/13; p = 0.026), but not for other diagnostic criteria. IBS patients with SIBO, compared to those without SIBO, reported significantly greater improvement in abdominal symptoms following rifaximin therapy (p < 0.002 overall IBS symptom severity). This improvement was most marked in D-IBS patients in whom all symptoms improved, including stool frequency and consistency (all p < 0.004). Combined LHBT/SOCT testing using a H2 5 ppm cutoff may identify a subgroup of IBS patients with SIBO. Pilot data examining the clinical response to rifaximin suggest that this subset of IBS patients may benefit more than those with a normal test. © 2014 John Wiley & Sons Ltd.

  16. 4. "TEST STAND NO. 13, CONCRETE STRUCTURAL PLAN AND ELEVATION." ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. "TEST STAND NO. 1-3, CONCRETE STRUCTURAL PLAN AND ELEVATION." Specifications No. OC11-50-10; Drawing No. 60-09-06; no sheet number within title block. D.O. SERIES 1109/12 REV. E. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract DA-04-353 Eng. 177, Rev. E; Date: 17 Dec. 1951. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-3, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  17. Postural Change Alters Autonomic Responses to Breath-Holding

    PubMed Central

    Taneja, Indu; Medow, Marvin S.; Clarke, Debbie; Ocon, Anthony; Stewart, Julian M.

    2011-01-01

    We used breath-holding during inspiration as a model to study the effect of pulmonary stretch on sympathetic nerve activity. Twelve healthy subjects (7 females, 5 males; 19–27 yrs) were tested while they performed an inspiratory breath-hold, both supine and during a 60° head-up tilt (HUT 60). Heart rate (HR), mean arterial blood pressure (MAP), respiration, muscle sympathetic nerve activity (MSNA), oxygen saturation (SaO2) and end tidal carbon dioxide (ETCO2) were recorded. Cardiac output (CO) and total peripheral resistance (TPR) were calculated. While breath-holding, ETCO2 increased significantly from 41±2 to 60±2 Torr during supine (p<0.05) and 38±2 Torr to 58±2 during HUT60 (p<0.05); SaO2 decreased from 98±1.5% to 95±1.4% supine, and from 97±1.5% to 94±1.7% during HUT60 (p=NS). MSNA showed three distinctive phases - a quiescent phase due to pulmonary stretch associated with decreased MAP, HR, CO and TPR; a second phase of baroreflex-mediated elevated MSNA which was associated with recovery of MAP and HR only during HUT60; CO and peripheral resistance returned to baseline while supine and HUT60; a third phase of further increased MSNA activity related to hypercapnia and associated with increased TPR. Breath-holding results in initial reductions of MSNA, MAP and HR by the pulmonary stretch reflex followed by increased sympathetic activity related to the arterial baroreflex and chemoreflex. PMID:20012144

  18. Characterization of the L4-L5-S1 motion segment using the stepwise reduction method.

    PubMed

    Jaramillo, Héctor Enrique; Puttlitz, Christian M; McGilvray, Kirk; García, José J

    2016-05-03

    The two aims of this study were to generate data for a more accurate calibration of finite element models including the L5-S1 segment, and to find mechanical differences between the L4-L5 and L5-S1 segments. Then, the range of motion (ROM) and facet forces for the L4-S1 segment were measured using the stepwise reduction method. This consists of sequentially testing and reducing each segment in nine stages by cutting the ligaments, facet capsules, and removing the nucleus. Five L4-S1 human segments (median: 65 years, range: 53-84 years, SD=11.0 years) were loaded under a maximum pure moment of 8Nm. The ROM was measured using stereo-photogrammetry via tracking of three markers and the facet contact forces (CF) were measured using a Tekscan system. The ROM for the L4-L5 segment and all stages showed good agreement with published data. The major differences in ROM between the L4-L5 and L5-S1 segments were found for lateral bending and all stages, for which the L4-L5 ROM was about 1.5-3 times higher than that of the L5-S1 segment, consistent with L5-S1 facet CF about 1.3 to 4 times higher than those measured for the L4-L5 segment. For the other movements and few stages, the L4-L5 ROM was significantly lower that of the L5-S1 segment. ROM and CF provide important baseline data for more accurate calibration of FE models and to understand the role that their structures play in lower lumbar spine mechanics. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. The cholesteryl octanoate breath test: a new procedure for detection of pancreatic insufficiency in the rat.

    PubMed

    Mundlos, S; Rhodes, J B; Hofmann, A F

    1987-09-01

    A breath test for the detection of pancreatic insufficiency was developed and tested in rats. The test features the hydrophobic molecule cholesteryl-1-14C-octanoate, which liberates 14C-octanoic acid when hydrolyzed by carboxyl ester lipase (cholesterol esterase). The 14C-octanoate is absorbed passively and rapidly metabolized to 14CO2, which is excreted in expired air. The compound was administered as an emulsion of cholesteryl octanoate, triglyceride, and lecithin to rats with mild pancreatic insufficiency induced by injecting the pancreatic duct with zein. The animals had exocrine pancreatic hypofunction based on the enzyme content of pancreas at autopsy. Amylase was reduced by 97.1 +/- 1.4%, whereas chymotrypsin was reduced by 73 +/- 14%. The p-aminobenzoic acid test was abnormal at 1 wk (21.68 +/- 8.4%), but become normal at 3 months (72.08 +/- 5.8%) after zein injection. Despite this, the animals gained weight and absorbed fat normally. The 14CO2 excretion rate in the 110-min interval after feeding was significantly reduced to 60% of sham-operated animals. Peak 14CO2 collections 20 min after feeding were reduced by 75 +/- 11%. 14CO2 output was completely normalized by administration of pancreatin prior to the test meal. The results suggest that a sensitive, noninvasive method for detecting deficiency of pancreatic carboxyl ester lipase (cholesterol esterase) secretion in the rat has been developed.

  20. [Breath alcohol test in construction sites in the Province of Belluno: a campaign in favour of health promotion and surveillance and against drinking].

    PubMed

    Marcolina, Daniela; De Marzo, Nicoletta; Riccio, Maria Teresa

    2011-01-01

    Health impairment due to alcohol use and abuse is well known, in terms of relationship with traffic accidents and work accidents. In Italy almost 10 per cent of accidents at work involve intoxicated people injuring themselves and innocent victims. Alcohol abuse is a factor involved in determining severe accidents in the construction industry and epidemiological studies demonstrated a relationship between an elevated alcohol use and severity of accidents. Since in the Province of Belluno alcohol consumption may be elevated also at work, the two Occupational Health Units (SPISAL) in the province organized a campaign of information and surveillance against alcohol consumption at work in the construction industry. This report shows the campaign results, mainly in terms of breath alcohol tests performed in construction workers. After an extensive information campaign we inspected 50 sites, where 105 construction companies were at work, and tested 294 workers by breath alcohol test. No-one refused the test. Only 2.7% construction workers were positive for the breath alcohol test, and the levels were not elevated. This study shows that the construction workers in Belluno Province are responsible drinkers and are well aware of the policy of prohibition of alcohol consumption at work.