Sample records for l-h power threshold

  1. Turbulence and sheared flow structures behind the isotopic dependence of the L-H power threshold on DIII-D

    NASA Astrophysics Data System (ADS)

    Yan, Z.; Gohil, P.; McKee, G. R.; Eldon, D.; Grierson, B.; Rhodes, T.; Petty, C. C.

    2017-12-01

    Measurements of long wavelength ({{k}\\bot }{{ρ }i}   <  1) density fluctuation characteristics in the edge of both Deuterium (D) and Hydrogen (H) plasmas across the L-H transition on DIII-D demonstrate the existence of single or double bands of low-wavenumber turbulence observed near the edge of H and D plasmas. These are strongly correlated with the L to H-mode transition power threshold (P LH) and can help explain the isotopic and density dependence of P LH, and how the P LH difference is reduced at higher density. Understanding and accurately predicting the L-H power threshold is critical to accessing to H-mode, and operating and achieving high confinement in burning plasmas such as ITER. Above about n e ~ 4  ×  1019 m-3, P LH is seen to converge for H and D, and increases for both with higher density. Surprisingly, the P LH increases significantly at low density in H but not in D plasmas. Two distinct frequency bands of density fluctuations are observed in the D plasmas at low density, n e ~ 1.2-1.5  ×  1019 m-3, but not in H plasmas with similar density, which appears to be correlated to the much lower power threshold in D at low density. Consistently, E  ×  B shear in the region of r/a ~ 0.95-1.0 is larger in D plasmas than in H plasmas at low density; as the P LH increases with increasing density, the dual mode structure disappears while E  ×  B shear becomes similar and small for both D and H plasmas at higher density, n e ~ 5  ×  1019 m-3, where P LH is similar for both D and H plasmas. The increased edge fluctuations, increased flow shear, and the dual-band nature of edge turbulence correlating with lower P LH may account for the strong isotope and density dependencies of P LH and support current L-H transition theories but suggest a complex behavior that can inform a more complete model of the L-H transition threshold.

  2. Turbulence and sheared flow structures behind the isotopic dependence of the L-H power threshold on DIII-D

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yan, Zheng; Gohil, Punit; McKee, George R.

    Measurements of long wavelength (kmore » $$\\perp$$p i < 1) density fluctuation characteristics in the edge of both Deuterium (D) and Hydrogen (H) plasmas across the L-H transition on DIII-D demonstrate the existence of single or double bands of low-wavenumber turbulence observed near the edge of H and D plasmas. These are strongly correlated with the L to H-mode transition power threshold (P LH) and can help explain the isotopic and density dependence of P LH, and how the P LH difference is reduced at higher density. Understanding and accurately predicting the L-H power threshold is critical to accessing to H-mode, and operating and achieving high confinement in burning plasmas such as ITER. Above about n e ~ 4 × 10 19 m -3, P LH is seen to converge for H and D, and increases for both with higher density. Surprisingly, the P LH increases significantly at low density in H but not in D plasmas. Two distinct frequency bands of density fluctuations are observed in the D plasmas at low density, n e ~ 1.2-1.5 × 10 19 m -3, but not in H plasmas with similar density, which appears to be correlated to the much lower power threshold in D at low density. Consistently, E × B shear in the region of r/a ~ 0.95-1.0 is larger in D plasmas than in H plasmas at low density; as the P LH increases with increasing density, the dual mode structure disappears while E × B shear becomes similar and small for both D and H plasmas at higher density, n e ~ 5 × 10 19 m -3, where P LH is similar for both D and H plasmas. Lastly, the increased edge fluctuations, increased flow shear, and the dualband nature of edge turbulence correlating with lower P LH may account for the strong isotope and density dependencies of PLH and support current L-H transition theories but suggest a complex behavior that can inform a more complete model of the L-H transition threshold.« less

  3. Turbulence and sheared flow structures behind the isotopic dependence of the L-H power threshold on DIII-D

    DOE PAGES

    Yan, Zheng; Gohil, Punit; McKee, George R.; ...

    2017-09-18

    Measurements of long wavelength (kmore » $$\\perp$$p i < 1) density fluctuation characteristics in the edge of both Deuterium (D) and Hydrogen (H) plasmas across the L-H transition on DIII-D demonstrate the existence of single or double bands of low-wavenumber turbulence observed near the edge of H and D plasmas. These are strongly correlated with the L to H-mode transition power threshold (P LH) and can help explain the isotopic and density dependence of P LH, and how the P LH difference is reduced at higher density. Understanding and accurately predicting the L-H power threshold is critical to accessing to H-mode, and operating and achieving high confinement in burning plasmas such as ITER. Above about n e ~ 4 × 10 19 m -3, P LH is seen to converge for H and D, and increases for both with higher density. Surprisingly, the P LH increases significantly at low density in H but not in D plasmas. Two distinct frequency bands of density fluctuations are observed in the D plasmas at low density, n e ~ 1.2-1.5 × 10 19 m -3, but not in H plasmas with similar density, which appears to be correlated to the much lower power threshold in D at low density. Consistently, E × B shear in the region of r/a ~ 0.95-1.0 is larger in D plasmas than in H plasmas at low density; as the P LH increases with increasing density, the dual mode structure disappears while E × B shear becomes similar and small for both D and H plasmas at higher density, n e ~ 5 × 10 19 m -3, where P LH is similar for both D and H plasmas. Lastly, the increased edge fluctuations, increased flow shear, and the dualband nature of edge turbulence correlating with lower P LH may account for the strong isotope and density dependencies of PLH and support current L-H transition theories but suggest a complex behavior that can inform a more complete model of the L-H transition threshold.« less

  4. L to H mode transition: Parametric dependencies of the temperature threshold

    DOE PAGES

    Bourdelle, C.; Chone, L.; Fedorczak, N.; ...

    2015-06-15

    The L to H mode transition occurs at a critical power which depends on various parameters, such as the magnetic field, the density, etc. Experimental evidence on various tokamaks (JET, ASDEX-Upgrade, DIII-D, Alcator C-Mod) points towards the existence of a critical temperature characterizing the transition. This criterion for the L-H transition is local and is therefore easier to be compared to theoretical approaches. In order to shed light on the mechanisms of the transition, simple theoretical ideas are used to derive a temperature threshold (T th). They are based on the stabilization of the underlying turbulence by a mean radialmore » electric field shear. The nature of the turbulence varies as the collisionality decreases, from resistive ballooning modes to ion temperature gradient and trapped electron modes. The obtained parametric dependencies of the derived T th are tested versus magnetic field, density, effective charge. Furthermore, various robust experimental observations are reproduced, in particular T th increases with magnetic field B and increases with density below the density roll-over observed on the power threshold.« less

  5. Linking the micro and macro: L-H transition dynamics and threshold physics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Malkov, M. A., E-mail: mmalkov@ucsd.edu; Diamond, P. H.; Miki, K.

    2015-03-15

    The links between the microscopic dynamics and macroscopic threshold physics of the LH transition are elucidated. Emphasis is placed on understanding the physics of power threshold scalings, and especially on understanding the minimum in the power threshold as a function of density P{sub thr} (n). By extending a numerical 1D model to evolve both electron and ion temperatures, including collisional coupling, we find that the decrease in P{sub thr} (n) along the low-density branch is due to the combination of an increase in collisional electron-to-ion energy transfer and an increase in the heating fraction coupled to the ions.more » Both processes strengthen the edge diamagnetic electric field needed to lock in the mean electric field shear for the L→H transition. The increase in P{sub thr} (n) along the high-density branch is due to the increase with ion collisionality of damping of turbulence-driven shear flows. Turbulence driven shear flows are needed to trigger the transition by extracting energy from the turbulence. Thus, we identify the critical transition physics components of the separatrix ion heat flux and the zonal flow excitation. The model reveals a power threshold minimum in density scans as a crossover between the threshold decrease supported by an increase in heat fraction received by ions (directly or indirectly, from electrons) and a threshold increase, supported by the rise in shear flow damping. The electron/ion heating mix emerges as important to the transition, in that it, together with electron-ion coupling, regulates the edge diamagnetic electric field shear. The importance of possible collisionless electron-ion heat transfer processes is explained.« less

  6. EDGE2D-EIRENE modelling of near SOL E r: possible impact on the H-mode power threshold

    NASA Astrophysics Data System (ADS)

    Chankin, A. V.; Delabie, E.; Corrigan, G.; Harting, D.; Maggi, C. F.; Meyer, H.; Contributors, JET

    2017-04-01

    Recent EDGE2D-EIRENE simulations of JET plasmas showed a significant difference between radial electric field (E r) profiles across the separatrix in two divertor configurations, with the outer strike point on the horizontal target (HT) and vertical target (VT) (Chankin et al 2016 Nucl. Mater. Energy, doi: 10.1016/j.nme.2016.10.004). Under conditions (input power, plasma density) where the HT plasma went into the H-mode, a large positive E r spike in the near scrape-off layer (SOL) was seen in the code output, leading to a very large E × B shear across the separatrix over a narrow region of a fraction of a cm width. No such E r feature was obtained in the code solution for the VT configuration, where the H-mode power threshold was found to be twice as high as in the HT configuration. It was hypothesised that the large E × B shear across the separatrix in the HT configuration could be responsible for the turbulence suppression leading to an earlier (at lower input power) L-H transition compared to the VT configuration. In the present work these ideas are extended to cover some other experimental observations on the H-mode power threshold variation with parameters which typically are not included in the multi-machine H-mode power threshold scalings, namely: ion mass dependence (isotope H-D-T exchange), dependence on the ion ∇B drift direction, and dependence on the wall material composition (ITER-like wall versus carbon wall in JET). In all these cases EDGE2D-EIRENE modelling shows larger positive E r spikes in the near SOL under conditions where the H-mode power threshold is lower, at least in the HT configuration.

  7. Assessment of effects of neutrals on the power threshold for L to H transitions in DIII-D

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owen, L.W.; Carreras, B.A.; Maingi, R.

    1998-11-01

    To assess the effect of edge neutrals on the low-to-high confinement transition threshold, a broad range of plasma discharges has been analyzed. From this analysis, the transition power divided by the density, at constant magnetic field, appears to be a function of a single parameter measuring the neutrals` effect. This results suggest that there is a missing parameter linked to the neutrals in the power threshold scaling laws.

  8. Isotope effects on L-H threshold and confinement in tokamak plasmas

    NASA Astrophysics Data System (ADS)

    Maggi, C. F.; Weisen, H.; Hillesheim, J. C.; Chankin, A.; Delabie, E.; Horvath, L.; Auriemma, F.; Carvalho, I. S.; Corrigan, G.; Flanagan, J.; Garzotti, L.; Keeling, D.; King, D.; Lerche, E.; Lorenzini, R.; Maslov, M.; Menmuir, S.; Saarelma, S.; Sips, A. C. C.; Solano, E. R.; Belonohy, E.; Casson, F. J.; Challis, C.; Giroud, C.; Parail, V.; Silva, C.; Valisa, M.; Contributors, JET

    2018-01-01

    The dependence of plasma transport and confinement on the main hydrogenic ion isotope mass is of fundamental importance for understanding turbulent transport and, therefore, for accurate extrapolations of confinement from present tokamak experiments, which typically use a single hydrogen isotope, to burning plasmas such as ITER, which will operate in deuterium-tritium mixtures. Knowledge of the dependence of plasma properties and edge transport barrier formation on main ion species is critical in view of the initial, low-activation phase of ITER operations in hydrogen or helium and of its implications on the subsequent operation in deuterium-tritium. The favourable scaling of global energy confinement time with isotope mass, which has been observed in many tokamak experiments, remains largely unexplained theoretically. Moreover, the mass scaling observed in experiments varies depending on the plasma edge conditions. In preparation for upcoming deuterium-tritium experiments in the JET tokamak with the ITER-like Be/W Wall (JET-ILW), a thorough experimental investigation of isotope effects in hydrogen, deuterium and tritium plasmas is being carried out, in order to provide stringent tests of plasma energy, particle and momentum transport models. Recent hydrogen and deuterium isotope experiments in JET-ILW on L-H power threshold, L-mode and H-mode confinement are reviewed and discussed in the context of past and more recent isotope experiments in tokamak plasmas, highlighting common elements as well as contrasting observations that have been reported. The experimental findings are discussed in the context of fundamental aspects of plasma transport models.

  9. Assessment of effects of neutrals on the power threshold for L to H transitions in DIII-D

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owen, L.W.; Carreras, B.A.; Maingi, R.

    1997-09-01

    To assess the effect of edge neutrals on the low to high confinement transition threshold, a broad range of plasma discharges has been analyzed. From this analysis, the transition power divided by the density, at constant magnetic field, appears to be a function of a single parameter measuring the neutrals` effect, This parameter cannot be uniquely identified. For instance, it may be the radial decay length of the neutral profile or the charge exchange damping rate at about r/a {approx} 0.95. This results suggest that there is a missing parameter linked to the neutrals in the power threshold scaling laws.

  10. Comparison of a field-based test to estimate functional threshold power and power output at lactate threshold.

    PubMed

    Gavin, Timothy P; Van Meter, Jessica B; Brophy, Patricia M; Dubis, Gabriel S; Potts, Katlin N; Hickner, Robert C

    2012-02-01

    It has been proposed that field-based tests (FT) used to estimate functional threshold power (FTP) result in power output (PO) equivalent to PO at lactate threshold (LT). However, anecdotal evidence from regional cycling teams tested for LT in our laboratory suggested that PO at LT underestimated FTP. It was hypothesized that estimated FTP is not equivalent to PO at LT. The LT and estimated FTP were measured in 7 trained male competitive cyclists (VO2max = 65.3 ± 1.6 ml O2·kg(-1)·min(-1)). The FTP was estimated from an 8-minute FT and compared with PO at LT using 2 methods; LT(Δ1), a 1 mmol·L(-1) or greater rise in blood lactate in response to an increase in workload and LT(4.0), blood lactate of 4.0 mmol·L(-1). The estimated FTP was equivalent to PO at LT(4.0) and greater than PO at LT(Δ1). VO2max explained 93% of the variance in individual PO during the 8-minute FT. When the 8-minute FT PO was expressed relative to maximal PO from the VO2max test (individual exercise performance), VO2max explained 64% of the variance in individual exercise performance. The PO at LT was not related to 8-minute FT PO. In conclusion, FTP estimated from an 8-minute FT is equivalent to PO at LT if LT(4.0) is used but is not equivalent for all methods of LT determination including LT(Δ1).

  11. L-H transition and pedestal studies on MAST

    NASA Astrophysics Data System (ADS)

    Meyer, H.; De Bock, M. F. M.; Conway, N. J.; Freethy, S. J.; Gibson, K.; Hiratsuka, J.; Kirk, A.; Michael, C. A.; Morgan, T.; Scannell, R.; Naylor, G.; Saarelma, S.; Saveliev, A. N.; Shevchenko, V. F.; Suttrop, W.; Temple, D.; Vann, R. G. L.; MAST, the; NBI Teams

    2011-11-01

    On MAST studies of the profile evolution of the electron temperature (Te), electron density (ne), radial electric field (Er) as well as novel measurements of the ion temperature (Ti) and toroidal current density (jphi) in the pedestal region allow further insight into the processes forming and defining the pedestal such as the H-mode access conditions and MHD stability. This includes studies of fast evolution of Te, ne and Er with Δt = 0.2 ms time resolution and the evolution of pe and jphi through an edge-localized mode (ELM) cycle. Measurements of the H-mode power threshold, PL-H revealed that about 40% more power is required to access H-mode in 4He than in D and that a change in the Z-position of the X-point can change PL-H significantly in single and double null configurations. The profile measurements in the L-mode phase prior to H-mode suggest that neither the gradient nor the value of the mean Te or Er at the plasma edge play a major role in triggering the L-H transition. After the transitions, first the fluctuations are suppressed, then the Er shear layer and the ne pedestal develops followed by the Te pedestal. In the banana regime at low collisionality (νsstarf) ∇Ti ≈ 0 leading to Ti > Te in the pedestal region with Ti ~ 0.3 keV close to the separatrix. A clear correlation of ∇Ti with νsstarf is observed. The measured jphi (using the motional Stark effect) Te and ne are in broad agreement with the common peeling-ballooning stability picture for ELMs and neoclassical calculations of the bootstrap current. The jphi and ∇pe evolution Δt ≈ 2 ms as well as profiles in discharges with counter current neutral beam injection raise questions with respect to this edge stability picture.

  12. Low threshold L-band mode-locked ultrafast fiber laser assisted by microfiber-based carbon nanotube saturable absorber

    NASA Astrophysics Data System (ADS)

    Lau, K. Y.; Ng, E. K.; Abu Bakar, M. H.; Abas, A. F.; Alresheedi, M. T.; Yusoff, Z.; Mahdi, M. A.

    2018-04-01

    We demonstrate a passively mode-locked erbium-doped fiber laser in L-band wavelength region with low mode-locking threshold employing a 1425 nm pump wavelength. The mode-locking regime is generated by microfiber-based saturable absorber using carbon nanotube-polymer composite in a ring cavity. This carbon nanotube saturable absorber shows saturation intensity of 9 MW/cm2. In this work, mode-locking laser threshold is observed at 36.4 mW pump power. At the maximum pump power of 107.6 mW, we obtain pulse duration at full-width half-maximum point of 490 fs and time bandwidth product of 0.33, which corresponds to 3-dB spectral bandwidth of 5.8 nm. The pulse repetition rate remains constant throughout the experiment at 5.8 MHz due to fixed cavity length of 35.5 m. Average output power and pulse energy of 10.8 mW and 1.92 nJ are attained respectively through a 30% laser output extracted from the mode-locked cavity. This work highlights the feasibility of attaining a low threshold mode-locked laser source to be employed as seed laser in L-band wavelength region.

  13. Is the Functional Threshold Power (FTP) a Valid Surrogate of the Lactate Threshold?

    PubMed

    Valenzuela, Pedro L; Morales, Javier S; Foster, Carl; Lucia, Alejandro; de la Villa, Pedro

    2018-05-10

    This study aimed to analyze the relationship between the Functional Threshold Power (FTP) and the Lactate Threshold (LT). 20 male cyclists performed an incremental test in which the LT was determined. At least 48 h later, they performed a 20-minute time trial and 95% of the mean power output (P20) was defined as FTP. Participants were divided into recreational (Peak Power Output [PPO] < 4.5 W∙kg -1 , n=11) or trained cyclists (PPO > 4.5 W∙kg -1 , n=9) according to their fitness status. The FTP (240 ± 35 W) was overall not significantly different (effect size[ES]=0.20, limits of agreement [LoA]=-2.4 ± 11.5%) from the LT (246 ± 24 W), and both markers were strongly correlated (r=0.95, p<0.0001). Accounting for the participants' fitness status, no significant differences were found between FTP and LT ([ES]=0.22; LoA=2.1 ± 7.8%) in TC, but FTP was significantly lower than the LT (p=0.0004, ES=0.81; LoA=-6.5 ± 8.3%) in RC. A significant relationship was found between relative PPO and the bias between FTP and the LT markers (r=0.77, p<0.0001). The FTP is a valid field test-based marker for the assessment of endurance fitness. However, caution should be taken when using the FTP interchangeably with the LT as the bias between markers seems to depend on the athletes' fitness status. Whereas the FTP provides a good estimate of the LT in trained cyclists, in recreational cyclists FTP may underestimate LT.

  14. Real-Time Analysis of the Heart Rate Variability During Incremental Exercise for the Detection of the Ventilatory Threshold.

    PubMed

    Shiraishi, Yasuyuki; Katsumata, Yoshinori; Sadahiro, Taketaro; Azuma, Koichiro; Akita, Keitaro; Isobe, Sarasa; Yashima, Fumiaki; Miyamoto, Kazutaka; Nishiyama, Takahiko; Tamura, Yuichi; Kimura, Takehiro; Nishiyama, Nobuhiro; Aizawa, Yoshiyasu; Fukuda, Keiichi; Takatsuki, Seiji

    2018-01-07

    It has never been possible to immediately evaluate heart rate variability (HRV) during exercise. We aimed to visualize the real-time changes in the power spectrum of HRV during exercise and to investigate its relationship to the ventilatory threshold (VT). Thirty healthy subjects (29.1±5.7 years of age) and 35 consecutive patients (59.0±13.2 years of age) with myocardial infarctions underwent cardiopulmonary exercise tests with an RAMP protocol ergometer. The HRV was continuously assessed with power spectral analyses using the maximum entropy method and projected on a screen without delay. During exercise, a significant decrease in the high frequency (HF) was followed by a drastic shift in the power spectrum of the HRV with a periodic augmentation in the low frequency/HF (L/H) and steady low HF. When the HRV threshold (HRVT) was defined as conversion from a predominant high frequency (HF) to a predominant low frequency/HF (L/H), the VO 2 at the HRVT (HRVT-VO 2 ) was substantially correlated with the VO 2 at the lactate threshold and VT) in the healthy subjects ( r =0.853 and 0.921, respectively). The mean difference between each threshold (0.65 mL/kg per minute for lactate threshold and HRVT, 0.53 mL/kg per minute for VT and HRVT) was nonsignificant ( P >0.05). Furthermore, the HRVT-VO 2 was also correlated with the VT-VO 2 in these myocardial infarction patients ( r =0.867), and the mean difference was -0.72 mL/kg per minute and was nonsignificant ( P >0.05). A HRV analysis with our method enabled real-time visualization of the changes in the power spectrum during exercise. This can provide additional information for detecting the VT. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  15. Investigation of the critical edge ion heat flux for L-H transitions in Alcator C-Mod and its dependence on B T

    NASA Astrophysics Data System (ADS)

    Schmidtmayr, M.; Hughes, J. W.; Ryter, F.; Wolfrum, E.; Cao, N.; Creely, A. J.; Howard, N.; Hubbard, A. E.; Lin, Y.; Reinke, M. L.; Rice, J. E.; Tolman, E. A.; Wukitch, S.; Ma, Y.; ASDEX Upgrade Team; Alcator C-Mod Team

    2018-05-01

    This paper presents investigations on the role of the edge ion heat flux for transitions from L-mode to H-mode in Alcator C-Mod. Previous results from the ASDEX Upgrade tokamak indicated that a critical value of edge ion heat flux per particle is needed for the transition. Analysis of C-Mod data confirms this result. The edge ion heat flux is indeed found to increase linearly with density at given magnetic field and plasma current. Furthermore, the Alcator C-Mod data indicate that the edge ion heat flux at the L-H transition also increases with magnetic field. Combining the data from Alcator C-Mod and ASDEX Upgrade yields a general expression for the edge ion heat flux at the L-H transition. These results are discussed from the point of view of the possible physics mechanism of the L-H transition. They are also compared to the L-H power threshold scaling and an extrapolation for ITER is given.

  16. A factorization approach to next-to-leading-power threshold logarithms

    NASA Astrophysics Data System (ADS)

    Bonocore, D.; Laenen, E.; Magnea, L.; Melville, S.; Vernazza, L.; White, C. D.

    2015-06-01

    Threshold logarithms become dominant in partonic cross sections when the selected final state forces gluon radiation to be soft or collinear. Such radiation factorizes at the level of scattering amplitudes, and this leads to the resummation of threshold logarithms which appear at leading power in the threshold variable. In this paper, we consider the extension of this factorization to include effects suppressed by a single power of the threshold variable. Building upon the Low-Burnett-Kroll-Del Duca (LBKD) theorem, we propose a decomposition of radiative amplitudes into universal building blocks, which contain all effects ultimately responsible for next-to-leading-power (NLP) threshold logarithms in hadronic cross sections for electroweak annihilation processes. In particular, we provide a NLO evaluation of the radiative jet function, responsible for the interference of next-to-soft and collinear effects in these cross sections. As a test, using our expression for the amplitude, we reproduce all abelian-like NLP threshold logarithms in the NNLO Drell-Yan cross section, including the interplay of real and virtual emissions. Our results are a significant step towards developing a generally applicable resummation formalism for NLP threshold effects, and illustrate the breakdown of next-to-soft theorems for gauge theory amplitudes at loop level.

  17. Automatic location of L/H transition times for physical studies with a large statistical basis

    NASA Astrophysics Data System (ADS)

    González, S.; Vega, J.; Murari, A.; Pereira, A.; Dormido-Canto, S.; Ramírez, J. M.; contributors, JET-EFDA

    2012-06-01

    Completely automatic techniques to estimate and validate L/H transition times can be essential in L/H transition analyses. The generation of databases with hundreds of transition times and without human intervention is an important step to accomplish (a) L/H transition physics analysis, (b) validation of L/H theoretical models and (c) creation of L/H scaling laws. An entirely unattended methodology is presented in this paper to build large databases of transition times in JET using time series. The proposed technique has been applied to a dataset of 551 JET discharges between campaigns C21 and C26. A prediction with discharges that show a clear signature in time series is made through the locating properties of the wavelet transform. It is an accurate prediction and the uncertainty interval is ±3.2 ms. The discharges with a non-clear pattern in the time series use an L/H mode classifier based on discharges with a clear signature. In this case, the estimation error shows a distribution with mean and standard deviation of 27.9 ms and 37.62 ms, respectively. Two different regression methods have been applied to the measurements acquired at the transition times identified by the automatic system. The obtained scaling laws for the threshold power are not significantly different from those obtained using the data at the transition times determined manually by the experts. The automatic methods allow performing physical studies with a large number of discharges, showing, for example, that there are statistically different types of transitions characterized by different scaling laws.

  18. Influence of the pump threshold on the single-frequency output power of singly resonant optical parametric oscillators

    NASA Astrophysics Data System (ADS)

    Sowade, R.; Breunig, I.; Kiessling, J.; Buse, K.

    2009-07-01

    We demonstrate that for a given pump source, there is an optimum pump threshold to achieve the maximum single-frequency output power in singly resonant optical parametric oscillators. Therefore, cavity losses and parametric amplification have to be adjusted. In particular, continuous-wave output powers of 1.5 W were achieved with a 2.5 cm lithium niobate crystal in comparison with 0.5 W by a 5 cm long crystal within the same cavity design. This counter-intuitive result of weaker amplification leading to larger powers can be explained using a model from L.B. Kreuzer (Proc. Joint Conf. Lasers and Opt.-Elect., p. 52, 1969). Kreuzer also states that single-mode operation is possible only up to pump powers which are 4.6 times the threshold value. Additionally, implementing an outcoupling mirror to increase losses, single-frequency waves with powers of 3 W at 3.2 µm and 7 W at 1.5 µm could be generated simultaneously.

  19. Threshold pump power of a solar-pumped dye laser

    NASA Technical Reports Server (NTRS)

    Lee, Ja H.; Kim, Kyung C.; Kim, Kyong H.

    1988-01-01

    Threshold solar power for dye laser pumping has been determined by measuring the gain of a rhodamine 6G dye laser amplifier at various solar-simulated irradiances on an amplifier cell. The measured threshold was 20,000 solar constants (2.7 kW/sq cm) for the dye volume of 2 x 5 x 40 cu mm and the optimum dye concentration of 0.001 M. The threshold is about one-third of that achievable with a high-intensity solar concentrator.

  20. Optimal Dynamic Sub-Threshold Technique for Extreme Low Power Consumption for VLSI

    NASA Technical Reports Server (NTRS)

    Duong, Tuan A.

    2012-01-01

    For miniaturization of electronics systems, power consumption plays a key role in the realm of constraints. Considering the very large scale integration (VLSI) design aspect, as transistor feature size is decreased to 50 nm and below, there is sizable increase in the number of transistors as more functional building blocks are embedded in the same chip. However, the consequent increase in power consumption (dynamic and leakage) will serve as a key constraint to inhibit the advantages of transistor feature size reduction. Power consumption can be reduced by minimizing the voltage supply (for dynamic power consumption) and/or increasing threshold voltage (V(sub th), for reducing leakage power). When the feature size of the transistor is reduced, supply voltage (V(sub dd)) and threshold voltage (V(sub th)) are also reduced accordingly; then, the leakage current becomes a bigger factor of the total power consumption. To maintain low power consumption, operation of electronics at sub-threshold levels can be a potentially strong contender; however, there are two obstacles to be faced: more leakage current per transistor will cause more leakage power consumption, and slow response time when the transistor is operated in weak inversion region. To enable low power consumption and yet obtain high performance, the CMOS (complementary metal oxide semiconductor) transistor as a basic element is viewed and controlled as a four-terminal device: source, drain, gate, and body, as differentiated from the traditional approach with three terminals: i.e., source and body, drain, and gate. This technique features multiple voltage sources to supply the dynamic control, and uses dynamic control to enable low-threshold voltage when the channel (N or P) is active, for speed response enhancement and high threshold voltage, and when the transistor channel (N or P) is inactive, to reduce the leakage current for low-leakage power consumption.

  1. Sub-threshold standard cell library design for ultra-low power biomedical applications.

    PubMed

    Li, Ming-Zhong; Ieong, Chio-In; Law, Man-Kay; Mak, Pui-In; Vai, Mang-I; Martins, Rui P

    2013-01-01

    Portable/Implantable biomedical applications usually exhibit stringent power budgets for prolonging battery life time, but loose operating frequency requirements due to small bio-signal bandwidths, typically below a few kHz. The use of sub-threshold digital circuits is ideal in such scenario to achieve optimized power/speed tradeoffs. This paper discusses the design of a sub-threshold standard cell library using a standard 0.18-µm CMOS technology. A complete library of 56 standard cells is designed and the methodology is ensured through schematic design, transistor width scaling and layout design, as well as timing, power and functionality characterization. Performance comparison between our sub-threshold standard cell library and a commercial standard cell library using a 5-stage ring oscillator and an ECG designated FIR filter is performed. Simulation results show that our library achieves a total power saving of 95.62% and a leakage power reduction of 97.54% when compared with the same design implemented by the commercial standard cell library (SCL).

  2. H-Ferritin Is Preferentially Incorporated by Human Erythroid Cells through Transferrin Receptor 1 in a Threshold-Dependent Manner

    PubMed Central

    Sakamoto, Soichiro; Kawabata, Hiroshi; Masuda, Taro; Uchiyama, Tatsuki; Mizumoto, Chisaki; Ohmori, Katsuyuki; Koeffler, H. Phillip; Kadowaki, Norimitsu; Takaori-Kondo, Akifumi

    2015-01-01

    Ferritin is an iron-storage protein composed of different ratios of 24 light (L) and heavy (H) subunits. The serum level of ferritin is a clinical marker of the body’s iron level. Transferrin receptor (TFR)1 is the receptor not only for transferrin but also for H-ferritin, but how it binds two different ligands and the blood cell types that preferentially incorporate H-ferritin remain unknown. To address these questions, we investigated hematopoietic cell-specific ferritin uptake by flow cytometry. Alexa Fluor 488-labeled H-ferritin was preferentially incorporated by erythroid cells among various hematopoietic cell lines examined, and was almost exclusively incorporated by bone marrow erythroblasts among human primary hematopoietic cells of various lineages. H-ferritin uptake by erythroid cells was strongly inhibited by unlabeled H-ferritin but was only partially inhibited by a large excess of holo-transferrin. On the other hand, internalization of labeled holo-transferrin by these cells was not inhibited by H-ferritin. Chinese hamster ovary cells lacking functional endogenous TFR1 but expressing human TFR1 with a mutated RGD sequence, which is required for transferrin binding, efficiently incorporated H-ferritin, indicating that TFR1 has distinct binding sites for H-ferritin and holo-transferrin. H-ferritin uptake by these cells required a threshold level of cell surface TFR1 expression, whereas there was no threshold for holo-transferrin uptake. The requirement for a threshold level of TFR1 expression can explain why among primary human hematopoietic cells, only erythroblasts efficiently take up H-ferritin. PMID:26441243

  3. Strategy for pH control and pH feedback-controlled substrate feeding for high-level production of L-tryptophan by Escherichia coli.

    PubMed

    Cheng, Li-Kun; Wang, Jian; Xu, Qing-Yang; Zhao, Chun-Guang; Shen, Zhi-Qiang; Xie, Xi-Xian; Chen, Ning

    2013-05-01

    Optimum production of L-tryptophan by Escherichia coli depends on pH. Here, we established conditions for optimizing the production of L-tryptophan. The optimum pH range was 6.5-7.2, and pH was controlled using a three-stage strategy [pH 6.5 (0-12 h), pH 6.8 (12-24 h), and pH 7.2 (24-38 h)]. Specifically, ammonium hydroxide was used to adjust pH during the initial 24 h, and potassium hydroxide and ammonium hydroxide (1:2, v/v) were used to adjust pH during 24-38 h. Under these conditions, NH4 (+) and K(+) concentrations were kept below the threshold for inhibiting L-tryptophan production. Optimization was also accomplished using ratios (v/v) of glucose to alkali solutions equal to 4:1 (5-24 h) and 6:1 (24-38 h). The concentration of glucose and the pH were controlled by adjusting the pH automatically. Applying a pH-feedback feeding method, the steady-state concentration of glucose was maintained at approximately 0.2 ± 0.02 g/l, and acetic acid accumulated to a concentration of 1.15 ± 0.03 g/l, and the plasmid stability was 98 ± 0.5 %. The final, optimized concentration of L-tryptophan was 43.65 ± 0.29 g/l from 52.43 ± 0.38 g/l dry cell weight.

  4. Generalised form of a power law threshold function for rainfall-induced landslides

    NASA Astrophysics Data System (ADS)

    Cepeda, Jose; Díaz, Manuel Roberto; Nadim, Farrokh; Høeg, Kaare; Elverhøi, Anders

    2010-05-01

    The following new function is proposed for estimating thresholds for rainfall-triggered landslides: I = α1Anα2Dβ, where I is rainfall intensity in mm/h, D is rainfall duration in h, An is the n-hours or n-days antecedent precipitation, and α1, α2, β and n are threshold parameters. A threshold model that combines two functions with different durations of antecedent precipitation is also introduced. A storm observation exceeds the threshold when the storm parameters are located at or above the two functions simultaneously. A novel optimisation procedure for estimating the threshold parameters is proposed using Receiver Operating Characteristics (ROC) analysis. The new threshold function and optimisation procedure are applied for estimating thresholds for triggering of debris flows in the Western Metropolitan Area of San Salvador (AMSS), El Salvador, where up to 500 casualties were produced by a single event. The resulting thresholds are I = 2322 A7d-1D-0.43 and I = 28534 A150d-1D-0.43 for debris flows having volumes greater than 3000 m3. Thresholds are also derived for debris flows greater than 200 000 m3 and for hyperconcentrated flows initiating in burned areas caused by forest fires. The new thresholds show an improved performance compared to the traditional formulations, indicated by a reduction in false alarms from 51 to 5 for the 3000 m3 thresholds and from 6 to 0 false alarms for the 200 000 m3 thresholds.

  5. Imposed Power of Breathing Associated With Use of an Impedance Threshold Device

    DTIC Science & Technology

    2007-02-01

    threshold device and a sham impedance threshold device. DESIGN: Prospective randomized blinded protocol. SETTING: University medical center. PATIENTS...for males). METHODS: The volunteers completed 2 trials of breathing through a face mask fitted with an active impedance threshold device set to open...at -7cmH 2 O pressure, or with a sham impedance threshold device, which was identical to the active device except that it did not contain an

  6. Mean and oscillating plasma flows and turbulence interactions across the L-H confinement transition.

    PubMed

    Conway, G D; Angioni, C; Ryter, F; Sauter, P; Vicente, J

    2011-02-11

    A complex interaction between turbulence driven E × B zonal flow oscillations, i.e., geodesic acoustic modes (GAMs), the turbulence, and mean equilibrium flows is observed during the low to high (L-H) plasma confinement mode transition in the ASDEX Upgrade tokamak. Below the L-H threshold at low densities a limit-cycle oscillation forms with competition between the turbulence level and the GAM flow shearing. At higher densities the cycle is diminished, while in the H mode the cycle duration becomes too short to sustain the GAM, which is replaced by large amplitude broadband flow perturbations. Initially GAM amplitude increases as the H-mode transition is approached, but is then suppressed in the H mode by enhanced mean flow shear.

  7. Catch bonds govern adhesion through L-selectin at threshold shear.

    PubMed

    Yago, Tadayuki; Wu, Jianhua; Wey, C Diana; Klopocki, Arkadiusz G; Zhu, Cheng; McEver, Rodger P

    2004-09-13

    Flow-enhanced cell adhesion is an unexplained phenomenon that might result from a transport-dependent increase in on-rates or a force-dependent decrease in off-rates of adhesive bonds. L-selectin requires a threshold shear to support leukocyte rolling on P-selectin glycoprotein ligand-1 (PSGL-1) and other vascular ligands. Low forces decrease L-selectin-PSGL-1 off-rates (catch bonds), whereas higher forces increase off-rates (slip bonds). We determined that a force-dependent decrease in off-rates dictated flow-enhanced rolling of L-selectin-bearing microspheres or neutrophils on PSGL-1. Catch bonds enabled increasing force to convert short-lived tethers into longer-lived tethers, which decreased rolling velocities and increased the regularity of rolling steps as shear rose from the threshold to an optimal value. As shear increased above the optimum, transitions to slip bonds shortened tether lifetimes, which increased rolling velocities and decreased rolling regularity. Thus, force-dependent alterations of bond lifetimes govern L-selectin-dependent cell adhesion below and above the shear optimum. These findings establish the first biological function for catch bonds as a mechanism for flow-enhanced cell adhesion.

  8. Threshold effect under nonlinear limitation of the intensity of high-power light

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tereshchenko, S A; Podgaetskii, V M; Gerasimenko, A Yu

    2015-04-30

    A model is proposed to describe the properties of limiters of high-power laser radiation, which takes into account the threshold character of nonlinear interaction of radiation with the working medium of the limiter. The generally accepted non-threshold model is a particular case of the threshold model if the threshold radiation intensity is zero. Experimental z-scan data are used to determine the nonlinear optical characteristics of media with carbon nanotubes, polymethine and pyran dyes, zinc selenide, porphyrin-graphene and fullerene-graphene. A threshold effect of nonlinear interaction between laser radiation and some of investigated working media of limiters is revealed. It is shownmore » that the threshold model more adequately describes experimental z-scan data. (nonlinear optical phenomena)« less

  9. The low density type III ELMy H-mode regime on JET-ILW: a low density H-mode compatible with a tungsten divertor?

    NASA Astrophysics Data System (ADS)

    Delabie, E.; Hillesheim, J. C.; Mailloux, J.; Maggi, C. F.; Rimini, F.; Solano, E. R.; JET contributors Team

    2016-10-01

    The threshold power to access H-mode on JET-ILW has a minimum as function of density. Power ramps in the low and high density branch show qualitatively very different behavior above threshold. In the high density branch, edge density and temperature abruptly increase after the L-H transition, and the plasma evolves into a type I ELMy H-mode. Transitions in the low density branch are gradual and lead to the formation of a temperature pedestal, without increase in edge density. These characteristics are reminiscent of the I-mode regime, but with high frequency ELM activity. The small ELMs allow stable H-mode operation with tolerable tungsten contamination, as long as both density and power stay below the type I ELM boundary. The density range in which the low density branch can be accessed scales favourably with toroidal field but unfavourably with isotope mass. At BT=3.4T, a stable H-mode has been obtained at = 2.9 1019 m-3 with up to 15 MW of heating power at H98y 0.9. Better knowledge of the operational boundaries of this high frequency ELM regime could provide insight in how to sustain it at higher heating power for high temperature scenarios. Work supported, in part, by the US DOE under Contract No. DE-AC05-00OR22725.

  10. Transport properties of NSTX-U L- and H-mode plasmas

    NASA Astrophysics Data System (ADS)

    Kaye, Stanley; Guttenfelder, Walter; Bell, Ron; Diallo, Ahmed; Leblanc, Ben; Podesta, Mario

    2016-10-01

    The confinement and transport properties of L- and H-mode plasmas in NSTX-U has been studied using the TRANSP code. A dedicated series of L-mode discharges was obtained to study the dependence of confinement and transport on power level and beam aiming angle. The latter is made possible by having two beamlines with 3 sources each, capable of injecting with tangency radii from Rtan = 50 to 130 cm (Rgeo = 92 cm). L-mode plasmas typically have confinement enhancement factors with H98y,2 =0.6 to 0.65, exhibiting a 25% decrease in confinement time as the beam power is raised from 1 to 3 MW. Associated with this is an increase in the electron thermal diffusivity in the core of the plasma from 3.5 to 10 m2/s. Electron thermal transport is the dominant energy loss channel in these plasmas. H-mode plasmas exhibit improved confinement, with H98y,2 =1 or above, and core electron thermal diffusivity values <1 m2/s. Details of these studies will be presented, along with the results of the beam tangency radius scan in L-mode plasmas. This research was supported by the U.S. Department of Energy contract # DE-AC02-09CH11466.

  11. Turbulence and sheared flow dynamics during q95 and density scans across the L-H transition on DIII-D

    NASA Astrophysics Data System (ADS)

    Yan, Zheng; McKee, George; Gohil, Punit; Schmitz, Lothar; Eldon, David; Grierson, Brian; Kriete, Matt; Rhodes, Terry; Petty, Craig

    2017-10-01

    Measurements of long wavelength density fluctuation characteristics have been obtained in the edge of Deuterium (D) plasmas across the L-H transition on DIII-D during density and q95 scans. The relative density fluctuation amplitude measured by Beam Emission Spectroscopy (BES) increases with higher q95. The power threshold is found to increase with plasma current (i.e., lower q95) but with complex density dependence: the largest increase of PLH is seen at ne 3.2e19 m-3. Interestingly, a dual counter-propagating mode is observed for cases when PLH is low. The existence of the dual mode is correlated with increasing flow shear. Estimation of the turbulence kinetic energy transfer from turbulence to the flow increases prior to the transition. The complex behaviors of the turbulence characteristics and dual frequency modes interactions impact the flow shear generation, the transition process and the power threshold scaling. Work supported by the US Department of Energy under DE-FG02-08ER54999, DE-AC02-09CH11466, DE-FC02-04ER54698, and DE-AC52-07NA27344.

  12. Cycling Power Outputs Predict Functional Threshold Power And Maximum Oxygen Uptake.

    PubMed

    Denham, Joshua; Scott-Hamilton, John; Hagstrom, Amanda D; Gray, Adrian J

    2017-09-11

    Functional threshold power (FTP) has emerged as a correlate of lactate threshold and is commonly assessed by recreational and professional cyclists for tailored exercise programing. To identify whether results from traditional aerobic and anaerobic cycling tests could predict FTP and V˙ O2max, we analysed the association between estimated FTP, maximum oxygen uptake (V˙ O2max [mlkgmin]) and power outputs obtained from a maximal cycle ergometry cardiopulmonary exercise test (CPET) and a 30-s Wingate test in a heterogeneous cohort of cycle-trained and untrained individuals (N=40, mean±SD; age: 32.6±10.6 y; relative V˙ O2max: 46.8±9.1 mlkgmin). The accuracy and sensitivity of the prediction equations was also assessed in young men (N=11) before and after a 6-wk sprint interval training intervention.Moderate to strong positive correlations were observed between FTP, relative V˙ O2max and power outputs achieved during incremental and 30-s Wingate cycling tests (r=.39-.965, all P<.05). While maximum power achieved during incremental cycle testing (Pmax) and relative V˙ O2max were predictors of FTP (r =.93), age and FTP (Wkg) estimated relative V˙ O2max (r=.80). Our findings confirm that FTP predominantly relies on aerobic metabolism and indicate both prediction models are sensitive enough to detect meaningful exercise-induced changes in FTP and V˙ O2max. Thus, coaches should consider limiting the time and load demands placed on athletes by conducting a maximal cycle ergometry CPET to estimate FTP. Additionally, a 20-min FTP test is a convenient method to assess V˙ O2max and is particularly relevant for exercise professionals without access to expensive CPET equipment.

  13. Estimating the dim light melatonin onset of adolescents within a 6-h sampling window: the impact of sampling rate and threshold method

    PubMed Central

    Crowley, Stephanie J.; Suh, Christina; Molina, Thomas A.; Fogg, Louis F.; Sharkey, Katherine M.; Carskadon, Mary A.

    2016-01-01

    Objective/Background Circadian rhythm sleep-wake disorders often manifest during the adolescent years. Measurement of circadian phase such as the Dim Light Melatonin Onset (DLMO) improves diagnosis and treatment of these disorders, but financial and time costs limit the use of DLMO phase assessments in clinic. The current analysis aims to inform a cost-effective and efficient protocol to measure the DLMO in older adolescents by reducing the number of samples and total sampling duration. Patients/Methods A total of 66 healthy adolescents (26 males) aged 14.8 to 17.8 years participated in a study in which sleep was fixed for one week before they came to the laboratory for saliva collection in dim light (<20 lux). Two partial 6-h salivary melatonin profiles were derived for each participant. Both profiles began 5 h before bedtime and ended 1 h after bedtime, but one profile was derived from samples taken every 30 mins (13 samples) and the other from samples taken every 60 mins (7 samples). Three standard thresholds (first 3 melatonin values mean + 2 SDs, 3 pg/mL, and 4 pg/mL) were used to compute the DLMO. Agreement between DLMOs derived from 30-min and 60-min sampling rates was determined using a Bland-Altman analysis; agreement between sampling rate DLMOs was defined as ± 1 h. Results and Conclusions Within a 6-h sampling window, 60-min sampling provided DLMO estimates that were within ± 1 h of DLMO from 30-min sampling, but only when an absolute threshold (3 pg/mL or 4 pg/mL) was used to compute the DLMO. Future analyses should be extended to include adolescents with circadian rhythm sleep-wake disorders. PMID:27318227

  14. Low power ovonic threshold switching characteristics of thin GeTe{sub 6} films using conductive atomic force microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manivannan, Anbarasu, E-mail: anbarasu@iiti.ac.in, E-mail: ranjith@iith.ac.in; Sahu, Smriti; Myana, Santosh Kumar

    2014-12-15

    Minimizing the dimensions of the electrode could directly impact the energy-efficient threshold switching and programming characteristics of phase change memory devices. A ∼12–15 nm AFM probe-tip was employed as one of the electrodes for a systematic study of threshold switching of as-deposited amorphous GeTe{sub 6} thin films. This configuration enables low power threshold switching with an extremely low steady state current in the on state of 6–8 nA. Analysis of over 48 different probe locations on the sample reveals a stable Ovonic threshold switching behavior at threshold voltage, V{sub TH} of 2.4 ± 0.5 V and the off state was retained below a holding voltage,more » V{sub H} of 0.6 ± 0.1 V. All these probe locations exhibit repeatable on-off transitions for more than 175 pulses at each location. Furthermore, by utilizing longer biasing voltages while scanning, a plausible nano-scale control over the phase change behavior from as-deposited amorphous to crystalline phase was studied.« less

  15. Non-abelian factorisation for next-to-leading-power threshold logarithms

    NASA Astrophysics Data System (ADS)

    Bonocore, D.; Laenen, E.; Magnea, L.; Vernazza, L.; White, C. D.

    2016-12-01

    Soft and collinear radiation is responsible for large corrections to many hadronic cross sections, near thresholds for the production of heavy final states. There is much interest in extending our understanding of this radiation to next-to-leading power (NLP) in the threshold expansion. In this paper, we generalise a previously proposed all-order NLP factorisation formula to include non-abelian corrections. We define a nonabelian radiative jet function, organising collinear enhancements at NLP, and compute it for quark jets at one loop. We discuss in detail the issue of double counting between soft and collinear regions. Finally, we verify our prescription by reproducing all NLP logarithms in Drell-Yan production up to NNLO, including those associated with double real emission. Our results constitute an important step in the development of a fully general resummation formalism for NLP threshold effects.

  16. Estimating the dim light melatonin onset of adolescents within a 6-h sampling window: the impact of sampling rate and threshold method.

    PubMed

    Crowley, Stephanie J; Suh, Christina; Molina, Thomas A; Fogg, Louis F; Sharkey, Katherine M; Carskadon, Mary A

    2016-04-01

    Circadian rhythm sleep-wake disorders (CRSWDs) often manifest during the adolescent years. Measurement of circadian phase such as the dim light melatonin onset (DLMO) improves diagnosis and treatment of these disorders, but financial and time costs limit the use of DLMO phase assessments in clinic. The current analysis aims to inform a cost-effective and efficient protocol to measure the DLMO in older adolescents by reducing the number of samples and total sampling duration. A total of 66 healthy adolescents (26 males) aged 14.8-17.8 years participated in a study; they were required to sleep on a fixed baseline schedule for a week before which they visited the laboratory for saliva collection in dim light (<20 lux). Two partial 6-h salivary melatonin profiles were derived for each participant. Both profiles began 5 h before bedtime and ended 1 h after bedtime, but one profile was derived from samples taken every 30 min (13 samples) and the other from samples taken every 60 min (seven samples). Three standard thresholds (first three melatonin values mean + 2 SDs, 3 pg/mL, and 4 pg/mL) were used to compute the DLMO. An agreement between DLMOs derived from 30-min and 60-min sampling rates was determined using Bland-Altman analysis; agreement between the sampling rate DLMOs was defined as ± 1 h. Within a 6-h sampling window, 60-min sampling provided DLMO estimates within ± 1 h of DLMO from 30-min sampling, but only when an absolute threshold (3 or 4 pg/mL) was used to compute the DLMO. Future analyses should be extended to include adolescents with CRSWDs. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Determining lower threshold concentrations for synergistic effects.

    PubMed

    Bjergager, Maj-Britt Andersen; Dalhoff, Kristoffer; Kretschmann, Andreas; Nørgaard, Katrine Banke; Mayer, Philipp; Cedergreen, Nina

    2017-01-01

    Though only occurring rarely, synergistic interactions between chemicals in mixtures have long been a point of focus. Most studies analyzing synergistic interactions used unrealistically high chemical concentrations. The aim of the present study is to determine the threshold concentration below which proven synergists cease to act as synergists towards the aquatic crustacean Daphnia magna. To do this, we compared several approaches and test-setups to evaluate which approach gives the most conservative estimate for the lower threshold for synergy for three known azole synergists. We focus on synergistic interactions between the pyrethroid insecticide, alpha-cypermethrin, and one of the three azole fungicides prochloraz, propiconazole or epoxiconazole measured on Daphnia magna immobilization. Three different experimental setups were applied: A standard 48h acute toxicity test, an adapted 48h test using passive dosing for constant chemical exposure concentrations, and a 14-day test. Synergy was defined as occuring in mixtures where either EC 50 values decreased more than two-fold below what was predicted by concentration addition (horizontal assessment) or as mixtures where the fraction of immobile organisms increased more than two-fold above what was predicted by independent action (vertical assessment). All three tests confirmed the hypothesis of the existence of a lower azole threshold concentration below which no synergistic interaction was observed. The lower threshold concentration, however, decreased with increasing test duration from 0.026±0.013μM (9.794±4.897μgL -1 ), 0.425±0.089μM (145.435±30.46μgL -1 ) and 0.757±0.253μM (249.659±83.44μgL -1 ) for prochloraz, propiconazole and epoxiconazole in standard 48h toxicity tests to 0.015±0.004μM (5.651±1.507μgL -1 ), 0.145±0.025μM (49.619±8.555μgL -1 ) and 0.122±0.0417μM (40.236±13.75μgL -1 ), respectively, in the 14-days tests. Testing synergy in relation to concentration addition provided

  18. Critical Power: An Important Fatigue Threshold in Exercise Physiology.

    PubMed

    Poole, David C; Burnley, Mark; Vanhatalo, Anni; Rossiter, Harry B; Jones, Andrew M

    2016-11-01

    : The hyperbolic form of the power-duration relationship is rigorous and highly conserved across species, forms of exercise, and individual muscles/muscle groups. For modalities such as cycling, the relationship resolves to two parameters, the asymptote for power (critical power [CP]) and the so-called W' (work doable above CP), which together predict the tolerable duration of exercise above CP. Crucially, the CP concept integrates sentinel physiological profiles-respiratory, metabolic, and contractile-within a coherent framework that has great scientific and practical utility. Rather than calibrating equivalent exercise intensities relative to metabolically distant parameters such as the lactate threshold or V˙O2max, setting the exercise intensity relative to CP unifies the profile of systemic and intramuscular responses and, if greater than CP, predicts the tolerable duration of exercise until W' is expended, V˙O2max is attained, and intolerance is manifested. CP may be regarded as a "fatigue threshold" in the sense that it separates exercise intensity domains within which the physiological responses to exercise can (CP) be stabilized. The CP concept therefore enables important insights into 1) the principal loci of fatigue development (central vs. peripheral) at different intensities of exercise and 2) mechanisms of cardiovascular and metabolic control and their modulation by factors such as O2 delivery. Practically, the CP concept has great potential application in optimizing athletic training programs and performance as well as improving the life quality for individuals enduring chronic disease.

  19. Solar Powered Remediation and pH Control

    DTIC Science & Technology

    2017-04-13

    Kitanidis, and P.L. McCarty. 2004. Possible factors controlling the effectiveness of bioenhanced dissolution of non -aqueous phase tetrachloroethene...FINAL REPORT Solar Powered Remediation and pH Control ESTCP Project ER-201033 APRIL 2017 David Lippincott, PG CB&I Federal... control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ORGANIZATION. 1. REPORT DATE (DD-MM-YYYY) 2. REPORT TYPE 3. DATES COVERED (From - To

  20. Modelling of transitions between L- and H-mode in JET high plasma current plasmas and application to ITER scenarios including tungsten behaviour

    NASA Astrophysics Data System (ADS)

    Koechl, F.; Loarte, A.; Parail, V.; Belo, P.; Brix, M.; Corrigan, G.; Harting, D.; Koskela, T.; Kukushkin, A. S.; Polevoi, A. R.; Romanelli, M.; Saibene, G.; Sartori, R.; Eich, T.; Contributors, JET

    2017-08-01

    The dynamics for the transition from L-mode to a stationary high Q DT H-mode regime in ITER is expected to be qualitatively different to present experiments. Differences may be caused by a low fuelling efficiency of recycling neutrals, that influence the post transition plasma density evolution on the one hand. On the other hand, the effect of the plasma density evolution itself both on the alpha heating power and the edge power flow required to sustain the H-mode confinement itself needs to be considered. This paper presents results of modelling studies of the transition to stationary high Q DT H-mode regime in ITER with the JINTRAC suite of codes, which include optimisation of the plasma density evolution to ensure a robust achievement of high Q DT regimes in ITER on the one hand and the avoidance of tungsten accumulation in this transient phase on the other hand. As a first step, the JINTRAC integrated models have been validated in fully predictive simulations (excluding core momentum transport which is prescribed) against core, pedestal and divertor plasma measurements in JET C-wall experiments for the transition from L-mode to stationary H-mode in partially ITER relevant conditions (highest achievable current and power, H 98,y ~ 1.0, low collisionality, comparable evolution in P net/P L-H, but different ρ *, T i/T e, Mach number and plasma composition compared to ITER expectations). The selection of transport models (core: NCLASS  +  Bohm/gyroBohm in L-mode/GLF23 in H-mode) was determined by a trade-off between model complexity and efficiency. Good agreement between code predictions and measured plasma parameters is obtained if anomalous heat and particle transport in the edge transport barrier are assumed to be reduced at different rates with increasing edge power flow normalised to the H-mode threshold; in particular the increase in edge plasma density is dominated by this edge transport reduction as the calculated neutral influx across the

  1. Multiwavelength ultralow-threshold lasing in quantum dot photonic crystal microcavities.

    PubMed

    Chakravarty, S; Bhattacharya, P; Chakrabarti, S; Mi, Z

    2007-05-15

    We demonstrate multiwavelength lasing of resonant modes in linear (L3) microcavities in a triangular-lattice 2D photonic crystal (PC) slab. The broad spontaneous emission spectrum from coupled quantum dots, modified by the PC microcavity, is studied as a function of the intensity of incident optical excitation. We observe lasing with an ultralow-threshold power of approximately 600 nW and an output efficiency of approximately 3% at threshold. Two other resonant modes exhibit weaker turnon characteristics and thresholds of approximately 2.5 and 200 microW, respectively.

  2. Water balance creates a threshold in soil pH at the global scale.

    PubMed

    Slessarev, E W; Lin, Y; Bingham, N L; Johnson, J E; Dai, Y; Schimel, J P; Chadwick, O A

    2016-11-21

    Soil pH regulates the capacity of soils to store and supply nutrients, and thus contributes substantially to controlling productivity in terrestrial ecosystems. However, soil pH is not an independent regulator of soil fertility-rather, it is ultimately controlled by environmental forcing. In particular, small changes in water balance cause a steep transition from alkaline to acid soils across natural climate gradients. Although the processes governing this threshold in soil pH are well understood, the threshold has not been quantified at the global scale, where the influence of climate may be confounded by the effects of topography and mineralogy. Here we evaluate the global relationship between water balance and soil pH by extracting a spatially random sample (n = 20,000) from an extensive compilation of 60,291 soil pH measurements. We show that there is an abrupt transition from alkaline to acid soil pH that occurs at the point where mean annual precipitation begins to exceed mean annual potential evapotranspiration. We evaluate deviations from this global pattern, showing that they may result from seasonality, climate history, erosion and mineralogy. These results demonstrate that climate creates a nonlinear pattern in soil solution chemistry at the global scale; they also reveal conditions under which soils maintain pH out of equilibrium with modern climate.

  3. Water balance creates a threshold in soil pH at the global scale

    NASA Astrophysics Data System (ADS)

    Slessarev, E. W.; Lin, Y.; Bingham, N. L.; Johnson, J. E.; Dai, Y.; Schimel, J. P.; Chadwick, O. A.

    2016-12-01

    Soil pH regulates the capacity of soils to store and supply nutrients, and thus contributes substantially to controlling productivity in terrestrial ecosystems. However, soil pH is not an independent regulator of soil fertility—rather, it is ultimately controlled by environmental forcing. In particular, small changes in water balance cause a steep transition from alkaline to acid soils across natural climate gradients. Although the processes governing this threshold in soil pH are well understood, the threshold has not been quantified at the global scale, where the influence of climate may be confounded by the effects of topography and mineralogy. Here we evaluate the global relationship between water balance and soil pH by extracting a spatially random sample (n = 20,000) from an extensive compilation of 60,291 soil pH measurements. We show that there is an abrupt transition from alkaline to acid soil pH that occurs at the point where mean annual precipitation begins to exceed mean annual potential evapotranspiration. We evaluate deviations from this global pattern, showing that they may result from seasonality, climate history, erosion and mineralogy. These results demonstrate that climate creates a nonlinear pattern in soil solution chemistry at the global scale; they also reveal conditions under which soils maintain pH out of equilibrium with modern climate.

  4. Power output during women's World Cup road cycle racing.

    PubMed

    Ebert, Tammie R; Martin, David T; McDonald, Warren; Victor, James; Plummer, John; Withers, Robert T

    2005-12-01

    Little information exists on the power output demands of competitive women's road cycle racing. The purpose of our investigation was to document the power output generated by elite female road cyclists who achieved success in FLAT and HILLY World Cup races. Power output data were collected from 27 top-20 World Cup finishes (19 FLAT and 8 HILLY) achieved by 15 nationally ranked cyclists (mean +/- SD; age: 24.1+/-4.0 years; body mass: 57.9+/-3.6 kg; height: 168.7+/-5.6 cm; VO2max 63.6+/-2.4 mL kg(-1) min(-1); peak power during graded exercise test (GXT(peak power)): 310+/-25 W). The GXT determined GXT(peak power), VO2peak lactate threshold (LT) and anaerobic threshold (AT). Bicycles were fitted with SRM powermeters, which recorded power (W), cadence (rpm), distance (km) and speed (km h(-1)). Racing data were analysed to establish time in power output and metabolic threshold bands and maximal mean power (MMP) over different durations. When compared to HILLY, FLAT were raced at a similar cadence (75+/-8 vs. 75+/-4 rpm, P=0.93) but higher speed (37.6+/-2.6 vs. 33.9+/-2.7 km h(-1), P=0.008) and power output (192+/-21 vs. 169+/-17 W, P=0.04; 3.3+/-0.3 vs. 3.0+/-0.4 W kg(-1), P=0.04). During FLAT races, riders spent significantly more time above 500 W, while greater race time was spent between 100 and 300 W (LT-AT) for HILLY races, with higher MMPs for 180-300 s. Racing terrain influenced the power output profiles of our internationally competitive female road cyclists. These data are the first to define the unique power output requirements associated with placing well in both flat and hilly women's World Cup cycling events.

  5. Predictions of H-mode performance in ITER

    NASA Astrophysics Data System (ADS)

    Budny, Robert

    2008-11-01

    Time-dependent integrated predictions of performance metrics such as the fusion power PDT, QDT≡ PDT/Pext, and alpha profiles are presented. The PTRANSP [1] code is used, along with GLF23 to predict plasma profiles, NUBEAM for NNBI and alpha heating, TORIC for ICRH, and TORAY for ECRH. Effects of sawteeth mixing, beam steering, beam shine-through, radiation loss, ash accumulation, and toroidal rotation are included. A total heating of Pext=73MW is assumed to achieve H-mode during the density and current ramp-up phase. Various mixes of NNBI, ICRH, and ECRH heating schemes are compared. After steady state conditions are achieved, Pext is stepped down to lower values to explore high QDT. Physics and computation uncertainties lead to ranges in predictions for PDT and QDT. Physics uncertainties include the L->H and H->L threshold powers, pedestal height, impurity and ash transport, and recycling. There are considerably more uncertainties predicting the peak value for QDT than for PDT. [0pt] [1] R.V. Budny, R. Andre, G. Bateman, F. Halpern, C.E. Kessel, A. Kritz, and D. McCune, Nuclear Fusion 48 (2008) 075005.

  6. 75 FR 51987 - Birch Power Company and Sorenson Engineering; Birch Power Company and Sorenson Leasing L.L.C...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-24

    ... Company and Sorenson Engineering; Birch Power Company and Sorenson Leasing L.L.C.; Notice of Application..., 2010, Birch Power Company and Sorenson Engineering (transferors) and Birch Power Company and Sorenson.... Applicant Contact: For both: Mr. Ted S. Sorenson, President, Birch Power Company, Sorenson Engineering, and...

  7. A new function for estimating local rainfall thresholds for landslide triggering

    NASA Astrophysics Data System (ADS)

    Cepeda, J.; Nadim, F.; Høeg, K.; Elverhøi, A.

    2009-04-01

    The widely used power law for establishing rainfall thresholds for triggering of landslides was first proposed by N. Caine in 1980. The most updated global thresholds presented by F. Guzzetti and co-workers in 2008 were derived using Caine's power law and a rigorous and comprehensive collection of global data. Caine's function is defined as I = α×Dβ, where I and D are the mean intensity and total duration of rainfall, and α and β are parameters estimated for a lower boundary curve to most or all the positive observations (i.e., landslide triggering rainfall events). This function does not account for the effect of antecedent precipitation as a conditioning factor for slope instability, an approach that may be adequate for global or regional thresholds that include landslides in surface geologies with a wide range of subsurface drainage conditions and pore-pressure responses to sustained rainfall. However, in a local scale and in geological settings dominated by a narrow range of drainage conditions and behaviours of pore-pressure response, the inclusion of antecedent precipitation in the definition of thresholds becomes necessary in order to ensure their optimum performance, especially when used as part of early warning systems (i.e., false alarms and missed events must be kept to a minimum). Some authors have incorporated the effect of antecedent rainfall in a discrete manner by first comparing the accumulated precipitation during a specified number of days against a reference value and then using a Caine's function threshold only when that reference value is exceeded. The approach in other authors has been to calculate threshold values as linear combinations of several triggering and antecedent parameters. The present study is aimed to proposing a new threshold function based on a generalisation of Caine's power law. The proposed function has the form I = (α1×Anα2)×Dβ, where I and D are defined as previously. The expression in parentheses is

  8. The effect of the isotope on the H-mode density limit

    NASA Astrophysics Data System (ADS)

    Huber, A.; Wiesen, S.; Bernert, M.; Brezinsek, S.; Chankin, A. V.; Sergienko, G.; Huber, V.; Abreu, P.; Boboc, A.; Brix, M.; Carralero, D.; Delabie, E.; Eich, T.; Esser, H. G.; Guillemaut, C.; Jachmich, S.; Joffrin, E.; Kallenbach, A.; Kruezi, U.; Lang, P.; Linsmeier, Ch.; Lowry, C. G.; Maggi, C. F.; Matthews, G. F.; Meigs, A. G.; Mertens, Ph.; Reimold, F.; Schweinzer, J.; Sips, G.; Stamp, M.; Viezzer, E.; Wischmeier, M.; Zohm, H.; contributors, JET; ASDEX Upgrade Team

    2017-08-01

    In order to understand the mechanisms for the H-mode density limit in machines with fully metallic walls, systematic investigations of H-mode density limit plasmas in experiments with deuterium and hydrogen external gas fuelling have been performed on JET-ILW. The observed H-mode density limit on JET in D- as well as in H-plasmas demonstrates similar operation phases: the stable H-mode phase, degrading H-mode, breakdown of the H-mode with energy confinement deterioration accompanied by a dithering cycling phase, followed by the L-mode phase. The density limit is not related to an inward collapse of the hot core plasma due to an overcooling of the plasma periphery by radiation. Indeed, independently of the isotopic effect, the total radiated power stay almost constant during the H-mode phase until the H-L back transition. It was observed in D- and H-plasmas that neither detachment, nor the X-point MARFE itself do trigger the H-L transition and that they thus do not present a limit on the plasma density. It is the plasma confinement, most likely determined by edge parameters, which is ultimately responsible for the H-mode DL. By comparing similar discharges but fuelled with either deuterium or hydrogen, we have found that the H-mode density limit exhibits a dependence on the isotope mass: the density limit is up to 35% lower in hydrogen compared to similar deuterium plasma conditions (the obtained density limit is in agreement with the Greenwald limit for D-plasma). In addition, the density limit is nearly independent of the applied power both in deuterium or hydrogen fuelling conditions. The measured Greenwald fractions are consistent with the predictions from a theoretical model based on an MHD instability theory in the near-SOL. The JET operational domains are significantly broadened when increasing the plasma effective mass (e.g. tritium or deuterium-tritium operation), i.e. the L to H power threshold is reduced whereas the density limit for the L-mode back

  9. Dental ceramics: a CIEDE2000 acceptability thresholds for lightness, chroma and hue differences.

    PubMed

    Perez, María Del Mar; Ghinea, Razvan; Herrera, Luis Javier; Ionescu, Ana Maria; Pomares, Héctor; Pulgar, Rosa; Paravina, Rade D

    2011-12-01

    To determine the visual 50:50% acceptability thresholds for lightness, chroma and hue for dental ceramics using CIEDE2000(K(L):K(C):K(H)) formula, and to evaluate the formula performance using different parametric factors. A 30-observer panel evaluated three subsets of ceramic samples: lightness subset (|ΔL'/ΔE(00)| ≥ 0.9), chroma subset (|ΔC'/ΔE(00)| ≥ 0.9) and hue subset (|ΔH'/ΔE(00)| ≥ 0.9). A Takagi-Sugeno-Kang Fuzzy Approximation was used as fitting procedure, and the 50:50% acceptability thresholds were calculated. A t-test was used in statistical analysis of the thresholds values. The performance of the CIEDE2000(1:1:1) and CIEDE2000(2:1:1) colour difference formulas against visual results was tested using PF/3 performance factor. The 50:50% CIEDE2000 acceptability thresholds were ΔL' = 2.92 (95% CI 1.22-4.96; r(2) = 0.76), ΔC' = 2.52 (95% CI 1.31-4.19; r(2) = 0.71) and ΔH' = 1.90 (95% CI 1.63-2.15; r(2) = 0.88). The 50:50% acceptability threshold for colour difference (ΔE') for CIEDE2000(1:1:1) was 1.87, whilst corresponding value for CIEDE2000(2:1:1) was 1.78. The PF/3 values were 139.86 for CIEDE2000(1:1:1), and 132.31 for CIEDE2000(2:1:1). There was a statistically significant difference amongst CIEDE2000 50:50% acceptability thresholds for lightness, chroma and hue differences for dental ceramics. The CIEDE2000(2:1:1) formula performed better than CIEDE2000(1:1:1). Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Dynamic and Tunable Threshold Voltage in Organic Electrochemical Transistors.

    PubMed

    Doris, Sean E; Pierre, Adrien; Street, Robert A

    2018-04-01

    In recent years, organic electrochemical transistors (OECTs) have found applications in chemical and biological sensing and interfacing, neuromorphic computing, digital logic, and printed electronics. However, the incorporation of OECTs in practical electronic circuits is limited by the relative lack of control over their threshold voltage, which is important for controlling the power consumption and noise margin in complementary and unipolar circuits. Here, the threshold voltage of OECTs is precisely tuned over a range of more than 1 V by chemically controlling the electrochemical potential at the gate electrode. This threshold voltage tunability is exploited to prepare inverters and amplifiers with improved noise margin and gain, respectively. By coupling the gate electrode with an electrochemical oscillator, single-transistor oscillators based on OECTs with dynamic time-varying threshold voltages are prepared. This work highlights the importance of electrochemistry at the gate electrode in determining the electrical properties of OECTs, and opens a path toward the system-level design of low-power OECT-based electronics. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Wireless power transmission for biomedical implants: The role of near-zero threshold CMOS rectifiers.

    PubMed

    Mohammadi, Ali; Redoute, Jean-Michel; Yuce, Mehmet R

    2015-01-01

    Biomedical implants require an electronic power conditioning circuitry to provide a stable electrical power supply. The efficiency of wireless power transmission is strongly dependent on the power conditioning circuitry specifically the rectifier. A cross-connected CMOS bridge rectifier is implemented to demonstrate the impact of thresholds of rectifiers on wireless power transfer. The performance of the proposed rectifier is experimentally compared with a conventional Schottky diode full wave rectifier over 9 cm distance of air and tissue medium between the transmitter and receiver. The output voltage generated by the CMOS rectifier across a 1 KΩ resistive load is around twice as much as the Schottky rectifier.

  12. β-alanine Supplementation Fails to Increase Peak Aerobic Power or Ventilatory Threshold in Aerobically Trained Males.

    PubMed

    Greer, Beau Kjerulf; Katalinas, Matthew E; Shaholli, Danielle M; Gallo, Paul M

    2016-01-01

    The purpose of the present study was to determine the effect of 30 days of β-alanine supplementation on peak aerobic power and ventilatory threshold (VT) in aerobically fit males. Fourteen males (28.8 ± 9.8 yrs) were assigned to either a β-alanine (SUPP) or placebo (PLAC) group; groups were matched for VT as it was the primary outcome measure. β-alanine supplementation consisted of 3 g/day for 7 days, and 6 g/day for the remaining 23 days. Before and after the supplementation period, subjects performed a continuous, graded cycle ergometry test to determine VO2 peak and VT. Metabolic data were analyzed using a 2 × 2 ANOVA with repeated measures. Thirty days of β-alanine supplementation (SUPP) did not increase VO2 peak (4.05 ± 0.6 vs. 4.14 ± 0.6 L/min) as compared to the placebo (PLAC) group (3.88 ± 0.2 vs. 3.97 ± 0.2 L/min) (p > .05). VT did not significantly improve in either the SUPP (3.21 ± 0.5 vs. 3.33 ± 0.5 L/min) or PLAC (3.19 ± 0.1 vs. 3.20 ± 0.1 L/min) group (p > .05). In conclusion, 30 days of β-alanine supplementation had no effect on VO2 peak or VT in aerobically trained athletes.

  13. Multi-pulse power injection and spheromak sustainment in SSPX

    NASA Astrophysics Data System (ADS)

    Stallard, B. W.; Hill, D. N.; Hooper, E. B.; Bulmer, R. H.; McLean, H. S.; Wood, R. D.; Woodruff, S.; Sspx Team

    2000-10-01

    Lawrence Livermore National Laboratory, Livermore, CA 94550, USA. Spheromak formation (gun injection phase) and sustainment experiments are now routine in SSPX using a multi-bank power system. Gun voltage, impedance, and power coupling show a clear current threshold dependence on gun flux (I_th~=λ_0φ_gun/μ_0), increasing with current above the threshold, and are compared with CTX results. The characteristic gun inductance, L_gun~=0.6 μH, derived from the gun voltage dependence on di/dt, is larger than expected from Corsica modeling of the spheromak equilibrium. It’s value is consistent with the n=1 ‘doughook’ mode structure reported in SPHEX and believed important for helicity injection and toroidal current drive. Results of helicity and power balance calculations of spheromak poloidal field buildup are compared with experiment and used to project sustainment with a future longer pulse power supply. This work was performed under the auspices of US DOE by the University of California Lawrence Livermore National Laboratory under Contract No. W-7405-ENG-48.

  14. Optimal thresholds for the estimation of area rain-rate moments by the threshold method

    NASA Technical Reports Server (NTRS)

    Short, David A.; Shimizu, Kunio; Kedem, Benjamin

    1993-01-01

    Optimization of the threshold method, achieved by determination of the threshold that maximizes the correlation between an area-average rain-rate moment and the area coverage of rain rates exceeding the threshold, is demonstrated empirically and theoretically. Empirical results for a sequence of GATE radar snapshots show optimal thresholds of 5 and 27 mm/h for the first and second moments, respectively. Theoretical optimization of the threshold method by the maximum-likelihood approach of Kedem and Pavlopoulos (1991) predicts optimal thresholds near 5 and 26 mm/h for lognormally distributed rain rates with GATE-like parameters. The agreement between theory and observations suggests that the optimal threshold can be understood as arising due to sampling variations, from snapshot to snapshot, of a parent rain-rate distribution. Optimal thresholds for gamma and inverse Gaussian distributions are also derived and compared.

  15. The minimal SUSY B - L model: simultaneous Wilson lines and string thresholds

    DOE PAGES

    Deen, Rehan; Ovrut, Burt A.; Purves, Austin

    2016-07-08

    In previous work, we presented a statistical scan over the soft supersymmetry breaking parameters of the minimal SUSY B - L model. For specificity of calculation, unification of the gauge parameters was enforced by allowing the two Z 3×Z 3 Wilson lines to have mass scales separated by approximately an order of magnitude. This introduced an additional “left-right” sector below the unification scale. In this paper, for three important reasons, we modify our previous analysis by demanding that the mass scales of the two Wilson lines be simultaneous and equal to an “average unification” mass U >. The present analysismore » is 1) more “natural” than the previous calculations, which were only valid in a very specific region of the Calabi-Yau moduli space, 2) the theory is conceptually simpler in that the left-right sector has been removed and 3) in the present analysis the lack of gauge unification is due to threshold effects — particularly heavy string thresholds, which we calculate statistically in detail. As in our previous work, the theory is renormalization group evolved from U > to the electroweak scale — being subjected, sequentially, to the requirement of radiative B - L and electroweak symmetry breaking, the present experimental lower bounds on the B - L vector boson and sparticle masses, as well as the lightest neutral Higgs mass of ~125 GeV. The subspace of soft supersymmetry breaking masses that satisfies all such constraints is presented and shown to be substantial.« less

  16. Extrafoveally applied flashing light affects contrast thresholds of achromatic and S-cone isolating, but not L-M cone modulated stimuli.

    PubMed

    Őze, A; Puszta, A; Buzás, P; Kóbor, P; Braunitzer, G; Nagy, A

    2018-06-21

    Flashing light stimulation is often used to investigate the visual system. However, the magnitude of the effect of this stimulus on the various subcortical pathways is not well investigated. The signals of conscious vision are conveyed by the magnocellular, parvocellular and koniocellular pathways. Parvocellular and koniocellular pathways (or more precisely, the L-M opponent and S-cone isolating channels) can be accessed by isoluminant red-green (L-M) and S-cone isolating stimuli, respectively. The main goal of the present study was to explore how costimulation with strong white extrafoveal light flashes alters the perception of stimuli specific to these pathways. Eleven healthy volunteers with negative neurological and ophthalmological history were enrolled for the study. Isoluminance of L-M and S-cone isolating sine-wave gratings was set individually, using the minimum motion procedure. The contrast thresholds for these stimuli as well as for achromatic gratings were determined by an adaptive staircase procedure where subjects had to indicate the orientation (horizontal, oblique or vertical) of the gratings. Thresholds were then determined again while a strong white peripheral light flash was presented 50 ms before each trial. Peripheral light flashes significantly (p < 0.05) increased the contrast thresholds of the achromatic and S-cone isolating stimuli. The threshold elevation was especially marked in case of the achromatic stimuli. However, the contrast threshold for the L-M stimuli was not significantly influenced by the light flashes. We conclude that extrafoveally applied light flashes influence predominantly the perception of achromatic stimuli. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Ionization cross sections of the Au L subshells by electron impact from the L3 threshold to 100 keV

    NASA Astrophysics Data System (ADS)

    Barros, Suelen F.; Vanin, Vito R.; Maidana, Nora L.; Martins, Marcos N.; García-Alvarez, Juan A.; Santos, Osvaldo C. B.; Rodrigues, Cleber L.; Koskinas, Marina F.; Fernández-Varea, José M.

    2018-01-01

    We measured the cross sections for Au Lα, Lβ, Lγ, Lℓ and Lη x-ray production by the impact of electrons with energies from the L3 threshold to 100 keV using a thin Au film whose mass thickness was determined by Rutherford Backscattering Spectrometry. The x-ray spectra were acquired with a Si drift detector, which allowed to separate the components of the Lγ multiplet lines. The measured Lα, Lβ, {{L}}{γ }1, L{γ }{2,3,6}, {{L}}{γ }{4,4\\prime }, {{L}}{γ }5, {{L}}{\\ell } and Lη x-ray production cross sections were then employed to derive Au L1, L2 and L3 subshell ionization cross sections with relative uncertainties of 8%, 7% and 7%, respectively; these figures include the uncertainties in the atomic relaxation parameters. The correction for the increase in electron path length inside the Au film was estimated by means of Monte Carlo simulations. The experimental ionization cross sections are about 10% above the state-of-the-art distorted-wave calculations.

  18. Validity of Lactate Thresholds in Inline Speed Skating.

    PubMed

    Hecksteden, Anne; Heinze, Tobias; Faude, Oliver; Kindermann, Wilfried; Meyer, Tim

    2015-09-01

    Lactate thresholds are commonly used as estimates of the highest workload where lactate production and elimination are in equilibrium (maximum lactate steady state [MLSS]). However, because of the high static load on propulsive muscles, lactate kinetics in inline speed skating may differ significantly from other endurance exercise modes. Therefore, the discipline-specific validity of lactate thresholds has to be verified. Sixteen competitive inline-speed skaters (age: 30 ± 10 years; training per week: 10 ± 4 hours) completed an exhaustive stepwise incremental exercise test (start 24 km·h, step duration 3 minutes, increment 2 km·h) to determine individual anaerobic threshold (IAT) and the workload corresponding to a blood lactate concentration of 4 mmol·L (LT4) and 2-5 continuous load tests of (up to) 30 minutes to determine MLSS. The IAT and LT4 correlated significantly with MLSS, and the mean differences were almost negligible (MLSS 29.5 ± 2.5 km·h; IAT 29.2 ± 2.0 km·h; LT4 29.6 ± 2.3 km·h; p > 0.1 for all differences). However, the variability of differences was considerable resulting in 95% limits of agreement in the upper range of values known from other endurance disciplines (2.6 km·h [8.8%] for IAT and 3.1 km·h [10.3%] for LT4). Consequently, IAT and LT4 may be considered as valid estimates of the MLSS in inline speed skating, but verification by means of a constant load test should be considered in cases of doubt or when optimal accuracy is needed (e.g., in elite athletes or scientific studies).

  19. 76 FR 45248 - PJM Interconnection, L.L.C., PJM Power Providers Group v. PJM Interconnection, L.L.C...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-28

    ...-002; Docket No. EL11-20-001] PJM Interconnection, L.L.C., PJM Power Providers Group v. PJM Interconnection, L.L.C.; Supplemental Notice of Staff Technical Conference On June 13, 2011, the Commission issued... Resources Services, Inc., Maryland Public Service Commission, Monitoring Analytics, L.L.C., National Rural...

  20. Predictions of high QDT in ITER H-mode plasmas

    NASA Astrophysics Data System (ADS)

    Budny, Robert

    2009-05-01

    Time-dependent integrated predictions of performance metrics such as the fusion power PDT, QDT≡ PDT/Pext, and alpha profiles are presented. The PTRANSP code (see R.V. Budny, R. Andre, G. Bateman, F. Halpern, C.E. Kessel, A. Kritz, and D. McCune, Nuclear Fusion 48 075005, and F. Halpern, A. Kritz, G. Bateman, R.V. Budny, and D. McCune, Phys. Plasmas 15 062505) is used, along with GLF23 to predict plasma profiles, NUBEAM for NNBI and alpha heating, TORIC for ICRH, and TORAY for ECRH. Effects of sawteeth mixing, beam steering, beam shine-through, radiation loss, ash accumulation, and toroidal rotation are included. A total heating of Pext=73MW is assumed to achieve H-mode during the density and current ramp-up phase. Various mixes of NNBI, ICRH, and ECRH heating schemes are compared. After steady state conditions are achieved, Pext is stepped down to lower values to explore high QDT. Physics and computation uncertainties lead to ranges in predictions for PDT and QDT. Physics uncertainties include the L->H and H->L threshold powers, pedestal height, impurity and ash transport, and recycling. There are considerably more uncertainties predicting the peak value for QDT than for PDT.

  1. Ellipticity dependence of the near-threshold harmonics of H2 in an elliptical strong laser field.

    PubMed

    Yang, Hua; Liu, Peng; Li, Ruxin; Xu, Zhizhan

    2013-11-18

    We study the ellipticity dependence of the near-threshold (NT) harmonics of pre-aligned H2 molecules using the time-dependent density functional theory. The anomalous maximum appearing at a non-zero ellipticity for the generated NT harmonics can be attributed to multiphoton effects of the orthogonally polarized component of the elliptical driving laser field. Our calculation also shows that the structure of the bound-state, such as molecular alignment and bond length, can be sensitively reflected on the ellipticity dependence of the near-threshold harmonics.

  2. 75 FR 82414 - Carolina Power & Light Company; H. B. Robinson Steam Electric Plant, Unit No. 2; Exemption

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-30

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 50-261; NRC-2010-0062] Carolina Power & Light Company; H. B. Robinson Steam Electric Plant, Unit No. 2; Exemption 1.0 Background Carolina Power & Light Company (CP&L, the licensee) is the holder of Renewed Facility Operating License No. DPR-23, which...

  3. An Ultra-Low Power Turning Angle Based Biomedical Signal Compression Engine with Adaptive Threshold Tuning.

    PubMed

    Zhou, Jun; Wang, Chao

    2017-08-06

    Intelligent sensing is drastically changing our everyday life including healthcare by biomedical signal monitoring, collection, and analytics. However, long-term healthcare monitoring generates tremendous data volume and demands significant wireless transmission power, which imposes a big challenge for wearable healthcare sensors usually powered by batteries. Efficient compression engine design to reduce wireless transmission data rate with ultra-low power consumption is essential for wearable miniaturized healthcare sensor systems. This paper presents an ultra-low power biomedical signal compression engine for healthcare data sensing and analytics in the era of big data and sensor intelligence. It extracts the feature points of the biomedical signal by window-based turning angle detection. The proposed approach has low complexity and thus low power consumption while achieving a large compression ratio (CR) and good quality of reconstructed signal. Near-threshold design technique is adopted to further reduce the power consumption on the circuit level. Besides, the angle threshold for compression can be adaptively tuned according to the error between the original signal and reconstructed signal to address the variation of signal characteristics from person to person or from channel to channel to meet the required signal quality with optimal CR. For demonstration, the proposed biomedical compression engine has been used and evaluated for ECG compression. It achieves an average (CR) of 71.08% and percentage root-mean-square difference (PRD) of 5.87% while consuming only 39 nW. Compared to several state-of-the-art ECG compression engines, the proposed design has significantly lower power consumption while achieving similar CRD and PRD, making it suitable for long-term wearable miniaturized sensor systems to sense and collect healthcare data for remote data analytics.

  4. F463L increases the potential of dofetilide on human ether-a-go-go-related gene (hERG) channels.

    PubMed

    Cheng, Gong; Wu, Jine; Han, Wenqi; Sun, Chaofeng

    2018-06-01

    Mutations in genes related to long QT syndrome (LQTS) is recognized as an independent risk of drug-induced LQTS. We previously screened a mutation F463L in a Chinese patient with LQT2, syncope, and epilepsy. Here, we planned to illustrate how F463L influences the action of dofetilide on hERG channels. F463L-hERG plasmids were transfected into the stable Human Embryonic Kidney 293 (HEK293) cells expressing WT-hERG to generate heterozygous mutant (WT + F463L-hERG). Whole-cell patch clamp and laser confocal scanning microscopy were used to evaluate electrophysiological consequences and the membrane distribution of hERG protein. In comparison of WT-hERG channels exposed to dofetilide, heterozygous F463L-hERG channels showed a reduction in the density of tail currents when exposed amidarone. F463L-hERG also altered the action of dofetilide on the gating properties of hERG channels. Images of dofetilide-treated cells expressing heterozygous F463L showed a severe retention and reduction of protein expression on the membrane compared to WT. In conclusion, dofetilide displays a powerful inhibitory effect on the currents from cells expressing heterozygous F463L, thus showing an additive suppression of currents by F463L with dofetilide. © 2018 Wiley Periodicals, Inc.

  5. The ventilatory anaerobic threshold is related to, but is lower than, the critical power, but does not explain exercise tolerance at this workrate.

    PubMed

    Okudan, N; Gökbel, H

    2006-03-01

    The aim of the present study was to investigate the relationships between critical power (CP), maximal aerobic power and the anaerobic threshold and whether exercise time to exhaustion and work at the CP can be used as an index in the determination of endurance. An incremental maximal cycle exercise test was performed on 30 untrained males aged 18-22 years. Lactate analysis was carried out on capillary blood samples at every 2 minutes. From gas exchange parameters and heart rate and lactate values, ventilatory anaerobic thresholds, heart rate deflection point and the onset of blood lactate accumulation were calculated. CP was determined with linear work-time method using 3 loads. The subjects exercised until they could no longer maintain a cadence above 24 rpm at their CP and exercise time to exhaustion was determined. CP was lower than the power output corresponding to VO2max, higher than the power outputs corresponding to anaerobic threshold. CP was correlated with VO2max and anaerobic threshold. Exercise time to exhaustion and work at CP were not correlated with VO2max and anaerobic threshold. Because of the correlations of the CP with VO2max and anaerobic threshold and no correlation of exercise time to exhaustion and work at the CP with these parameters, we conclude that exercise time to exhaustion and work at the CP cannot be used as an index in the determination of endurance.

  6. Recent progress towards a physics-based understanding of the H-mode transition

    DOE PAGES

    Tynan, G. R.; Cziegler, I.; Diamond, P. H.; ...

    2016-01-22

    Results from recent experiment and numerical simulation point towards a picture of the L-H transition in which edge shear flows interacting with edge turbulence create the conditions needed to produce a non-zero turbulent Reynolds stress at and just inside the LCFS during L-mode discharges. This stress acts to reinforce the shear flow at this location and the flow drive gets stronger as heating is increased. The L-H transition ensues when the rate of work done by this stress is strong enough to drive the shear flow to large values, which then grows at the expense of the turbulence intensity. Themore » drop in turbulence intensity momentarily reduces the heat flux across the magnetic flux surface, which then allows the edge plasma pressure gradient to build. A sufficiently strong ion pressure gradient then locks in the H-mode state. The results are in general agreement with previously published reduced 0D and 1D predator prey models. An extended predator–prey model including separate ion and electron heat channels yields a non-monotonic power threshold dependence on plasma density provided that the fraction of heat deposited on the ions increases with plasma density. Possible mechanisms to explain other macroscopic transition threshold criteria are identified. A number of open questions and unexplained observations are identified, and must be addressed and resolved in order to build a physics-based model that can yield predictions of the macroscopic conditions needed for accessing H-mode.« less

  7. Critical Power: An Important Fatigue Threshold in Exercise Physiology

    PubMed Central

    Poole, David C.; Burnley, Mark; Vanhatalo, Anni; Rossiter, Harry B.; Jones, Andrew M.

    2016-01-01

    The hyperbolic form of the power-duration relationship is rigorous and highly conserved across species, forms of exercise and individual muscles/muscle groups. For modalities such as cycling, the relationship resolves to two parameters, the asymptote for power (critical power, CP) and the so-called W′ (work doable above CP), which together predict the tolerable duration of exercise above CP. Crucially, the CP concept integrates sentinel physiological profiles - respiratory, metabolic and contractile - within a coherent framework that has great scientific and practical utility. Rather than calibrating equivalent exercise intensities relative to metabolically distant parameters such as the lactate threshold or V̇O2 max, setting the exercise intensity relative to CP unifies the profile of systemic and intramuscular responses and, if greater than CP, predicts the tolerable duration of exercise until W′ is expended, V̇O2 max is attained, and intolerance is manifested. CP may be regarded as a ‘fatigue threshold’ in the sense that it separates exercise intensity domains within which the physiological responses to exercise can (CP) be stabilized. The CP concept therefore enables important insights into 1) the principal loci of fatigue development (central vs. peripheral) at different intensities of exercise, and 2) mechanisms of cardiovascular and metabolic control and their modulation by factors such as O2 delivery. Practically, the CP concept has great potential application in optimizing athletic training programs and performance as well as improving the life quality for individuals enduring chronic disease. PMID:27031742

  8. An Ultra-Low Power Turning Angle Based Biomedical Signal Compression Engine with Adaptive Threshold Tuning

    PubMed Central

    Zhou, Jun; Wang, Chao

    2017-01-01

    Intelligent sensing is drastically changing our everyday life including healthcare by biomedical signal monitoring, collection, and analytics. However, long-term healthcare monitoring generates tremendous data volume and demands significant wireless transmission power, which imposes a big challenge for wearable healthcare sensors usually powered by batteries. Efficient compression engine design to reduce wireless transmission data rate with ultra-low power consumption is essential for wearable miniaturized healthcare sensor systems. This paper presents an ultra-low power biomedical signal compression engine for healthcare data sensing and analytics in the era of big data and sensor intelligence. It extracts the feature points of the biomedical signal by window-based turning angle detection. The proposed approach has low complexity and thus low power consumption while achieving a large compression ratio (CR) and good quality of reconstructed signal. Near-threshold design technique is adopted to further reduce the power consumption on the circuit level. Besides, the angle threshold for compression can be adaptively tuned according to the error between the original signal and reconstructed signal to address the variation of signal characteristics from person to person or from channel to channel to meet the required signal quality with optimal CR. For demonstration, the proposed biomedical compression engine has been used and evaluated for ECG compression. It achieves an average (CR) of 71.08% and percentage root-mean-square difference (PRD) of 5.87% while consuming only 39 nW. Compared to several state-of-the-art ECG compression engines, the proposed design has significantly lower power consumption while achieving similar CRD and PRD, making it suitable for long-term wearable miniaturized sensor systems to sense and collect healthcare data for remote data analytics. PMID:28783079

  9. H-mode transitions and limit cycle oscillations from mean field transport equations

    DOE PAGES

    Staebler, Gary M.; Groebner, Richard J.

    2014-11-28

    The mean field toroidal and parallel momentum transport equations will be shown to admit both onestep transitions to suppressed transport (L/H) and limit cycle oscillations (LCO). Both types of transitions are driven by the suppression of turbulence by the mean field ExB velocity shear. Using experimental data to evaluate the coefficients of a reduced transport model, the observed frequency of the LCO can be matched. The increase in the H-mode power threshold above and below a minimum density agrees with the trends in the model. Both leading and lagging phase relations between the turbulent density fluctuation amplitude and the ExBmore » velocity shear can occur depending on the evolution of the linear growth rate of the turbulence. As a result, the transport solutions match the initial phase of the L/H transition where the poloidal and ExB velocities are observed to change, and the density fluctuations drop, faster than the diamagnetic velocity.« less

  10. 76 FR 46793 - PJM Interconnection, L.L.C.; PJM Power Providers Group v. PJM Interconnection, L.L.C.; Notice...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-03

    ...-002; Docket No. EL11-20-001] PJM Interconnection, L.L.C.; PJM Power Providers Group v. PJM Interconnection, L.L.C.; Notice Establishing Post-Technical Comment Period As indicated in the June 29, 2011... issues related to PJM Interconnection, L.L.C. (PJM)'s Minimum Offer Price Rule (MOPR) and resources...

  11. Ethanol catalytic optical driven deposition for 1D and 2D materials with ultra-low power threshold of 0 dBm

    NASA Astrophysics Data System (ADS)

    Wang, Hao; Chen, Bohua; Xiao, Xu; Guo, Chaoshi; Zhang, Xiaoyan; Wang, Jun; Jiang, Meng; Wu, Kan; Chen, Jianping

    2018-01-01

    We have demonstrated a generalized optical driven deposition method, ethanol catalytic deposition (ECD) method, which is widely applicable to the deposition of a broad range of one-dimensional (1D) and two-dimensional (2D) materials with common deposition parameters. Using ECD method, deposition of 1D material carbon nanotubes and 2D materials MoS2, MoSe2, WS2 and WSe2 on tapered fiber has been demonstrated with the threshold power as low as 0 dBm. To our knowledge, this is the lowest threshold power ever reported in optical driven deposition, noting that the conventional optical driven deposition has a threshold typically near 15 dBm. It means ECD method can significantly reduce the power requirement and simplify the setup of the optical driven deposition as well as its wide applicability to different materials, which benefits the research on optical nonlinearity and ultrafast photonics of 1D and 2D materials.

  12. High power single mode 980 nm AlGaInAs/AlGaAs quantum well lasers with a very low threshold current

    NASA Astrophysics Data System (ADS)

    Zhen, Dong; Cuiluan, Wang; Hongqi, Jing; Suping, Liu; Xiaoyu, Ma

    2013-11-01

    To achieve low threshold current as well as high single mode output power, a graded index separate confinement heterostructure (GRIN-SCH) AlGaInAs/AlGaAs quantum well laser with an optimized ridge waveguide was fabricated. The threshold current was reduced to 8 mA. An output power of 76 mW was achieved at 100 mA current at room temperature, with a slope efficiency of 0.83 W/A and a horizon divergent angle of 6.3°. The maximum single mode output power of the device reached as high as 450 mW.

  13. Understanding L-H transition in tokamak fusion plasmas

    NASA Astrophysics Data System (ADS)

    Xu, Guosheng; Wu, Xingquan

    2017-03-01

    This paper reviews the current state of understanding of the L-H transition phenomenon in tokamak plasmas with a focus on two central issues: (a) the mechanism for turbulence quick suppression at the L-H transition; (b) the mechanism for subsequent generation of sheared flow. We briefly review recent advances in the understanding of the fast suppression of edge turbulence across the L-H transition. We uncover a comprehensive physical picture of the L-H transition by piecing together a number of recent experimental observations and insights obtained from 1D and 2D simulation models. Different roles played by diamagnetic mean flow, neoclassical-driven mean flow, turbulence-driven mean flow, and turbulence-driven zonal flows are discussed and clarified. It is found that the L-H transition occurs spontaneously mediated by a shift in the radial wavenumber spectrum of edge turbulence, which provides a critical evidence for the theory of turbulence quench by the flow shear. Remaining questions and some key directions for future investigations are proposed. This work was supported by National Magnetic Confinement Fusion Science Program of China under Contracts No. 2015GB101000, No. 2013GB106000, and No. 2013GB107000 and National Natural Science Foundation of China under Contracts No. 11575235 and No. 11422546.

  14. The influence of ambient temperature on power at anaerobic threshold determined based on blood lactate concentration and myoelectric signals.

    PubMed

    Tyka, Aleksander; Pałka, Tomasz; Tyka, Anna; Cisoń, Tomasz; Szyguła, Zbigniew

    2009-01-01

    To compare the mechanical power and physiological parameters in males at the lactate (LAAT) and integrated electromyographic (IEMGAT) anaerobic thresholds during exercise testing at 23 degrees C, 31 degrees C and 37 degrees C. Fifteen men aged 21.9+/-1.80 years performed an incremental exercise test on a cycle ergometer at pedal frequency of 60 rpm. The test began at the power output of 120 W which was increased by 30 W every 3 min. Heart rate, oxygen uptake, carbon dioxide in expired air and minute ventilation were monitored. Venous blood samples were collected at 30 s before termination of each 3-min stage of test to determine the lactate anaerobic threshold. IEMGAT for vastus lateralis (VL) and rectus femoris (RF) muscles were regarded as the inflection point at which a non-linear increase in IEMGAT occurred. IEMGAT for VL and RF were similar for all the three temperatures. IEMGAT (VL and RF) correlated closely with LAAT at ambient temperatures of 23 degrees C (r = 0.91), 31 degrees C (r = 0.96) and 37 degrees C (r = 0.97). Repeated measures analysis of variance (ANOVA) revealed that the mechanical power at LAAT and IEMGAT was higher at 23 degrees C (202+/-26.5 W vs. 205+/-22.9 W) than at 31 degrees C (186+/-20.2 W vs. 186.2+/-20.2 W) and 37 degrees C (175.5+/-25.2 W vs. 175.3+/-20.0 W) for LAAT and IEMGAT respectively (p < 0.01). Higher ambient temperature induced a decrease in the mechanical power at which the anaerobic threshold occurred. The high correlation between LAAT and IEMGAT (r = 0.91-0.97) indicated that IEMGAT can be used as a practical and reliable, non-invasive method for assessment of the anaerobic threshold.

  15. Effects of alpha stopping power modelling on the ignition threshold in a directly-driven inertial confinement fusion capsule

    NASA Astrophysics Data System (ADS)

    Temporal, Mauro; Canaud, Benoit; Cayzac, Witold; Ramis, Rafael; Singleton, Robert L.

    2017-05-01

    The alpha-particle energy deposition mechanism modifies the ignition conditions of the thermonuclear Deuterium-Tritium fusion reactions, and constitutes a key issue in achieving high gain in Inertial Confinement Fusion implosions. One-dimensional hydrodynamic calculations have been performed with the code Multi-IFE [R. Ramis, J. Meyer-ter-Vehn, Comput. Phys. Commun. 203, 226 (2016)] to simulate the implosion of a capsule directly irradiated by a laser beam. The diffusion approximation for the alpha energy deposition has been used to optimize three laser profiles corresponding to different implosion velocities. A Monte-Carlo package has been included in Multi-IFE to calculate the alpha energy transport, and in this case the energy deposition uses both the LP [C.K. Li, R.D. Petrasso, Phys. Rev. Lett. 70, 3059 (1993)] and the BPS [L.S. Brown, D.L. Preston, R.L. Singleton Jr., Phys. Rep. 410, 237 (2005)] stopping power models. Homothetic transformations that maintain a constant implosion velocity have been used to map out the transition region between marginally-igniting and high-gain configurations. The results provided by the two models have been compared and it is found that - close to the ignition threshold - in order to produce the same fusion energy, the calculations performed with the BPS model require about 10% more invested energy with respect to the LP model.

  16. Evaluation of Treatment Thresholds for Unconjugated Hyperbilirubinemia in Preterm Infants: Effects on Serum Bilirubin and on Hearing Loss?

    PubMed Central

    Verkerk, Paul H.; Dijk, Peter H.; Van Straaten, Henrica L. M.

    2013-01-01

    Background Severe unconjugated hyperbilirubinemia may cause deafness. In the Netherlands, 25% lower total serum bilirubin (TSB) treatment thresholds were recently implemented for preterm infants. Objective To determine the rate of hearing loss in jaundiced preterms treated at high or at low TSB thresholds. Design/Methods In this retrospective study conducted at two neonatal intensive care units in the Netherlands, we included preterms (gestational age <32 weeks) treated for unconjugated hyperbilirubinemia at high or low TSB thresholds. Infants with major congenital malformations, syndromes, chromosomal abnormalities or toxoplasmosis, rubella, cytomegalovirus, herpes, syphilis, and human immunodeficiency infections were excluded. We analyzed clinical characteristics and TSB levels during the first ten postnatal days. After two failed automated Auditory Brainstem Response (ABR) tests we used the results of the diagnostic ABR examination to define normal, unilateral, and bilateral hearing loss (>35 dB). Results There were 479 patients in the high and 144 in the low threshold group. Both groups had similar gestational ages (29.5 weeks) and birth weights (1300 g). Mean and mean peak TSB levels were significantly lower after the implementation of the novel thresholds: 152±43 µmol/L and 212±52 µmol/L versus 131±37 µmol/L and 188±46 µmol/L for the high versus low thresholds, respectively (P<0.001). The incidence of hearing loss was 2.7% (13/479) in the high and 0.7% (1/144) in the low TSB threshold group (NNT = 50, 95% CI, 25–3302). Conclusions Implementation of lower treatment thresholds resulted in reduced mean and peak TSB levels. The incidence of hearing impairment in preterms with a gestational age <32 weeks treated at low TSB thresholds was substantially lower compared to preterms treated at high TSB thresholds. Further research with larger sample sizes and power is needed to determine if this effect is statistically significant. PMID:23667532

  17. Evaluation of treatment thresholds for unconjugated hyperbilirubinemia in preterm infants: effects on serum bilirubin and on hearing loss?

    PubMed

    Hulzebos, Christian V; van Dommelen, Paula; Verkerk, Paul H; Dijk, Peter H; Van Straaten, Henrica L M

    2013-01-01

    Severe unconjugated hyperbilirubinemia may cause deafness. In the Netherlands, 25% lower total serum bilirubin (TSB) treatment thresholds were recently implemented for preterm infants. To determine the rate of hearing loss in jaundiced preterms treated at high or at low TSB thresholds. In this retrospective study conducted at two neonatal intensive care units in the Netherlands, we included preterms (gestational age <32 weeks) treated for unconjugated hyperbilirubinemia at high or low TSB thresholds. Infants with major congenital malformations, syndromes, chromosomal abnormalities or toxoplasmosis, rubella, cytomegalovirus, herpes, syphilis, and human immunodeficiency infections were excluded. We analyzed clinical characteristics and TSB levels during the first ten postnatal days. After two failed automated Auditory Brainstem Response (ABR) tests we used the results of the diagnostic ABR examination to define normal, unilateral, and bilateral hearing loss (>35 dB). There were 479 patients in the high and 144 in the low threshold group. Both groups had similar gestational ages (29.5 weeks) and birth weights (1300 g). Mean and mean peak TSB levels were significantly lower after the implementation of the novel thresholds: 152 ± 43 µmol/L and 212 ± 52 µmol/L versus 131 ± 37 µmol/L and 188 ± 46 µmol/L for the high versus low thresholds, respectively (P<0.001). The incidence of hearing loss was 2.7% (13/479) in the high and 0.7% (1/144) in the low TSB threshold group (NNT = 50, 95% CI, 25-3302). Implementation of lower treatment thresholds resulted in reduced mean and peak TSB levels. The incidence of hearing impairment in preterms with a gestational age <32 weeks treated at low TSB thresholds was substantially lower compared to preterms treated at high TSB thresholds. Further research with larger sample sizes and power is needed to determine if this effect is statistically significant.

  18. 10. BOILER #16 (BUILDING L8) TO LEFT, L.P. AND H.P. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. BOILER #16 (BUILDING L8) TO LEFT, L.P. AND H.P. BOILER ROOMS (BUILDINGS L4 AND L2) TO RIGHT, AND STEPHENS SUBSTATION (BUILDING L6) IN BACKGROUND, FROM THE ROOF OF THE POWERHOUSE EXTENSION (BUILDING L5) - Portland General Electric Company, Station "L", 1841 Southeast Water Street, Portland, Multnomah County, OR

  19. Thermal Chemistry of Cp*W(NO)(CH2CMe3)(H)(L) Complexes (L = Lewis Base).

    PubMed

    Fabulyak, Diana; Handford, Rex C; Holmes, Aaron S; Levesque, Taleah M; Wakeham, Russell J; Patrick, Brian O; Legzdins, Peter; Rosenfeld, Devon C

    2017-01-03

    The complexes trans-Cp*W(NO)(CH 2 CMe 3 )(H)(L) (Cp* = η 5 -C 5 Me 5 ) result from the treatment of Cp*W(NO)(CH 2 CMe 3 ) 2 in n-pentane with H 2 (∼1 atm) in the presence of a Lewis base, L. The designation of a particular geometrical isomer as cis or trans indicates the relative positions of the alkyl and hydrido ligands in the base of a four-legged piano-stool molecular structure. The thermal behavior of these complexes is markedly dependent on the nature of L. Some of them can be isolated at ambient temperatures [e.g., L = P(OMe) 3 , P(OPh) 3 , or P(OCH 2 ) 3 CMe]. Others undergo reductive elimination of CMe 4 via trans to cis isomerization to generate the 16e reactive intermediates Cp*W(NO)(L). These intermediates can intramolecularly activate a C-H bond of L to form 18e cis complexes that may convert to the thermodynamically more stable trans isomers [e.g., Cp*W(NO)(PPh 3 ) initially forms cis-Cp*W(NO)(H)(κ 2 -PPh 2 C 6 H 4 ) that upon being warmed in n-pentane at 80 °C isomerizes to trans-Cp*W(NO)(H)(κ 2 -PPh 2 C 6 H 4 )]. Alternatively, the Cp*W(NO)(L) intermediates can effect the intermolecular activation of a substrate R-H to form trans-Cp*W(NO)(R)(H)(L) complexes [e.g., L = P(OMe) 3 or P(OCH 2 ) 3 CMe; R-H = C 6 H 6 or Me 4 Si] probably via their cis isomers. These latter activations are also accompanied by the formation of some Cp*W(NO)(L) 2 disproportionation products. An added complication in the L = P(OMe) 3 system is that thermolysis of trans-Cp*W(NO)(CH 2 CMe 3 )(H)(P(OMe) 3 ) results in it undergoing an Arbuzov-like rearrangement and being converted mainly into [Cp*W(NO)(Me)(PO(OMe) 2 )] 2 , which exists as a mixture of two isomers. All new complexes have been characterized by conventional and spectroscopic methods, and the solid-state molecular structures of most of them have been established by single-crystal X-ray crystallographic analyses.

  20. [Effect of endogenous H2S on platelet L-Arg transport].

    PubMed

    Duan, Wen-zhuo; Wang, Yi-peng; Gong, Hai-min

    2010-05-01

    To observe the effect of novel air neuromodulator H2S on platelet function of L-Arg transport for discussing H2S of effect on platelet function. Saturate H2S solution as donate made rat rich platelet plasma and pre-incubation rat platelet with different density of H2S. To measure the velocity of L-Arg transport in platelet by radioactivity technique. At different concentrations of H2S (6.25, 12.5, 25, 50, 100 micromol/L), the velocity of L-Arg transport was lower than that in control. H2S reduced rapidly the Vmax and velocity of L-Arg transport in platelet (P < 0.05) and this effect had no effect to Km. H2S can affect platelet function by changing rapidly platelet L-Arg transport system function.

  1. Comments on Jeong-Won Lee and Diane Lemonnier Schallert's "The Relative Contribution of L2 Language Proficiency and L1 Reading Ability to L2 Reading Performance: A Test of the Threshold Hypothesis in an EFL Context."

    ERIC Educational Resources Information Center

    Bamford, Julian; Day, Richard R.; Schallert, Diane Lemonnier; Lee, Jeong-Won

    1998-01-01

    Provides reactions to an article, "The Relative Contribution of L2 Language Proficiency and L1 Reading Ability to L2 Reading Performance: A Test of the Threshold Hypothesis in an EFL Context" published in an earlier issue of this journal (v31 n4). The authors of the article respond to these reactions. (Author/VWL)

  2. [Determination of the anaerobic threshold by the rate of ventilation and cardio interval variability].

    PubMed

    Seluianov, V N; Kalinin, E M; Pak, G D; Maevskaia, V I; Konrad, A H

    2011-01-01

    The aim of this work is to develop methods for determining the anaerobic threshold according to the rate of ventilation and cardio interval variability during the test with stepwise increases load on the cycle ergometer and treadmill. In the first phase developed the method for determining the anaerobic threshold for lung ventilation. 49 highly skilled skiers took part in the experiment. They performed a treadmill ski-walking test with sticks with gradually increasing slope from 0 to 25 degrees, the slope increased by one degree every minute. In the second phase we developed a method for determining the anaerobic threshold according dynamics ofcardio interval variability during the test. The study included 86 athletes of different sports specialties who performed pedaling on the cycle ergometer "Monarch" in advance. Initial output was 25 W, power increased by 25 W every 2 min. The pace was steady--75 rev/min. Measurement of pulmonary ventilation and oxygen and carbon dioxide content was performed using gas analyzer COSMED K4. Sampling of arterial blood was carried from the ear lobe or finger, blood lactate concentration was determined using an "Akusport" instrument. RR-intervals registration was performed using heart rate monitor Polar s810i. As a result, it was shown that the graphical method for determining the onset of anaerobic threshold ventilation (VAnP) coincides with the accumulation of blood lactate 3.8 +/- 0.1 mmol/l when testing on a treadmill and 4.1 +/- 0.6 mmol/1 on the cycle ergometer. The connection between the measure of oxygen consumption at VAnP and the dispersion of cardio intervals (SD1), derived regression equation: VO2AnT = 0.35 + 0.01SD1W + 0.0016SD1HR + + 0.106SD1(ms), l/min; (R = 0.98, error evaluation function 0.26 L/min, p < 0.001), where W (W)--Power, HR--heart rate (beats/min), SD1--cardio intervals dispersion (ms) at the moment of registration of cardio interval threshold.

  3. Evaluation of Stress Corrosion Resistance Properties of 15CrMoR(H) in H2S Environment

    NASA Astrophysics Data System (ADS)

    Zhang, Yiliang; Wang, Jing; Wu, Mingyao; Li, Shurui; Liu, Wenbin

    To evaluate the hydrogen resistant properties of the 15CrMoR(H) with new smelting process, according to NACE and National Standards, three tests including NACE standard tensile test, NACE standard bent-beam test and hydrogen induced cracking test are executed in saturated hydrogen sulfide(H2S) environment. Stress-life mathematical model of this material is given by analyzing and fitting the results of tensile test. Test results show that the threshold sth of tensile test is 0.7R eL(252MPa); the threshold nominal stress SC of bent-beam is higher than 4.5 R eL (1620MPa); for HIC test, the crack length rate CLR is 4.40%, the crack thickness rate CTR is 0.87% and the crack sensitive rate CSR is 0.04%. Compare with EFC standard, the safety margin of HIC test is 3.4, 3.4 and 37.5 times respectively. All the experimental results show that the new 15CrMoR(H) material has excellent H2S environmental cracking resistance properties.

  4. Interplay of threshold resummation and hadron mass corrections in deep inelastic processes

    DOE PAGES

    Accardi, Alberto; Anderle, Daniele P.; Ringer, Felix

    2015-02-01

    We discuss hadron mass corrections and threshold resummation for deep-inelastic scattering lN-->l'X and semi-inclusive annihilation e +e - → hX processes, and provide a prescription how to consistently combine these two corrections respecting all kinematic thresholds. We find an interesting interplay between threshold resummation and target mass corrections for deep-inelastic scattering at large values of Bjorken x B. In semi-inclusive annihilation, on the contrary, the two considered corrections are relevant in different kinematic regions and do not affect each other. A detailed analysis is nonetheless of interest in the light of recent high precision data from BaBar and Belle onmore » pion and kaon production, with which we compare our calculations. For both deep inelastic scattering and single inclusive annihilation, the size of the combined corrections compared to the precision of world data is shown to be large. Therefore, we conclude that these theoretical corrections are relevant for global QCD fits in order to extract precise parton distributions at large Bjorken x B, and fragmentation functions over the whole kinematic range.« less

  5. Polymer collapse, protein folding, and the percolation threshold.

    PubMed

    Meirovitch, Hagai

    2002-01-15

    We study the transition of polymers in the dilute regime from a swollen shape at high temperatures to their low-temperature structures. The polymers are modeled by a single self-avoiding walk (SAW) on a lattice for which l of the monomers (the H monomers) are self-attracting, i.e., if two nonbonded H monomers become nearest neighbors on the lattice they gain energy of interaction (epsilon = -/epsilon/); the second type of monomers, denoted P, are neutral. This HP model was suggested by Lau and Dill (Macromolecules 1989, 22, 3986-3997) to study protein folding, where H and P are the hydrophobic and polar amino acid residues, respectively. The model is simulated on the square and simple cubic (SC) lattices using the scanning method. We show that the ground state and the sharpness of the transition depend on the lattice, the fraction g of the H monomers, as well as on their arrangement along the chain. In particular, if the H monomers are distributed at random and g is larger than the site percolation threshold of the lattice, a collapsed transition is very likely to occur. This conclusion, drawn for the lattice models, is also applicable to proteins where an effective lattice with coordination number between that of the SC lattice and the body centered cubic lattice is defined. Thus, the average fraction of hydrophobic amino acid residues in globular proteins is found to be close to the percolation threshold of the effective lattice.

  6. Theory of Auditory Thresholds in Primates

    NASA Astrophysics Data System (ADS)

    Harrison, Michael J.

    2001-03-01

    The influence of thermal pressure fluctuations at the tympanic membrane has been previously investigated as a possible determinant of the threshold of hearing in humans (L.J. Sivian and S.D. White, J. Acoust. Soc. Am. IV, 4;288(1933).). More recent work has focussed more precisely on the relation between statistical mechanics and sensory signal processing by biological means in creatures' brains (W. Bialek, in ``Physics of Biological Systems: from molecules to species'', H. Flyvberg et al, (Eds), p. 252; Springer 1997.). Clinical data on the frequency dependence of hearing thresholds in humans and other primates (W.C. Stebbins, ``The Acoustic Sense of Animals'', Harvard 1983.) has long been available. I have derived an expression for the frequency dependence of hearing thresholds in primates, including humans, by first calculating the frequency dependence of thermal pressure fluctuations at eardrums from damped normal modes excited in model ear canals of given simple geometry. I then show that most of the features of the clinical data are directly related to the frequency dependence of the ratio of thermal noise pressure arising from without to that arising from within the masking bandwidth which signals must dominate in order to be sensed. The higher intensity of threshold signals in primates smaller than humans, which is clinically observed over much but not all of the human auditory spectrum is shown to arise from their smaller meatus dimensions. note

  7. TES/Aura L2 Water Vapor (H2O) Limb V6 (TL2H2OL)

    Atmospheric Science Data Center

    2018-03-01

    TES/Aura L2 Water Vapor (H2O) Limb (TL2H2OL) News:  TES News ... Level:  L2 Platform:  TES/Aura L2 Water Vapor Spatial Coverage:  27 x 23 km Limb ... Access: OPeNDAP Parameters:  H2O Water Volume Mixing Radio Precision Vertical Resolution Order ...

  8. Threshold altitude resulting in decompression sickness

    NASA Technical Reports Server (NTRS)

    Kumar, K. V.; Waligora, James M.; Calkins, Dick S.

    1990-01-01

    A review of case reports, hypobaric chamber training data, and experimental evidence indicated that the threshold for incidence of altitude decompression sickness (DCS) was influenced by various factors such as prior denitrogenation, exercise or rest, and period of exposure, in addition to individual susceptibility. Fitting these data with appropriate statistical models makes it possible to examine the influence of various factors on the threshold for DCS. This approach was illustrated by logistic regression analysis on the incidence of DCS below 9144 m. Estimations using these regressions showed that, under a noprebreathe, 6-h exposure, simulated EVA profile, the threshold for symptoms occurred at approximately 3353 m; while under a noprebreathe, 2-h exposure profile with knee-bends exercise, the threshold occurred at 7925 m.

  9. H2-O2 combustion powered steam-MHD central power systems

    NASA Technical Reports Server (NTRS)

    Seikel, G. R.; Smith, J. M.; Nichols, L. D.

    1974-01-01

    Estimates are made for both the performance and the power costs of H2-O2 combustion powered steam-MHD central power systems. Hydrogen gas is assumed to be transmitted by pipe from a remote coal gasifier into the city and converted to electricity in a steam MHD plant having an integral gaseous oxygen plant. These steam MHD systems appear to offer an attractive alternative to both in-city clean fueled conventional steam power plants and to remote coal fired power plants with underground electric transmission into the city.

  10. The salt-taste threshold in untreated hypertensive patients.

    PubMed

    Kim, Chang-Yeon; Ye, Mi-Kyung; Lee, Young Soo

    2017-01-01

    The salt-taste threshold can influence the salt appetite, and is thought to be another marker of sodium intake. Many studies have mentioned the relationship between the sodium intake and blood pressure (BP). The aim of this study was to evaluate the relationship between the salt-taste threshold and urinary sodium excretion in normotensive and hypertensive groups. We analyzed 199 patients (mean age 52 years, male 47.3%) who underwent 24-h ambulatory BP monitoring (ABPM). Hypertension was diagnosed as an average daytime systolic BP of ≥135 mmHg or diastolic BP of ≥85 mmHg by the ABPM. We assessed the salt-taste threshold using graded saline solutions. The salt-taste threshold, 24-h urinary sodium and potassium excretion, and echocardiographic data were compared between the control and hypertensive groups. The detection and recognition threshold of the salt taste did not significantly differ between the control and hypertensive groups. The 24-h urinary sodium excretion of hypertensive patients was significantly higher than that of the control group (140.9 ± 59.8 vs. 117.9 ± 57.2 mEq/day, respectively, p  = 0.011). Also, the urinary sodium-potassium ratio was significantly higher in the hypertensive patients. There was no correlation between the salt-taste threshold and 24-h urinary sodium excretion. The salt-taste threshold might not be related to the BP status as well as the 24-h urinary sodium excretion.

  11. TES/Aura L2 Water Vapor (H2O) Limb V6 (TL2H2OLS)

    Atmospheric Science Data Center

    2018-03-01

    TES/Aura L2 Water Vapor (H2O) Limb (TL2H2OLS) News:  TES News ... Level:  L2 Platform:  TES/Aura L2 Water Vapor Spatial Coverage:  27 x 23 km Limb ... Access:  OPeNDAP Parameters:  H2O Water Volume Mixing Radio Precision Vertical Resolution Order ...

  12. Anomalous pH-Dependent Nanofluidic Salinity Gradient Power.

    PubMed

    Yeh, Li-Hsien; Chen, Fu; Chiou, Yu-Ting; Su, Yen-Shao

    2017-12-01

    Previous studies on nanofluidic salinity gradient power (NSGP), where energy associated with the salinity gradient can be harvested with ion-selective nanopores, all suggest that nanofluidic devices having higher surface charge density should have higher performance, including osmotic power and conversion efficiency. In this manuscript, this viewpoint is challenged and anomalous counterintuitive pH-dependent NSGP behaviors are reported. For example, with equal pH deviation from its isoelectric point (IEP), the nanopore at pH < IEP is shown to have smaller surface charge density but remarkably higher NSGP performance than that at pH > IEP. Moreover, for sufficiently low pH, the NSGP performance decreases with lowering pH (increasing nanopore charge density). As a result, a maximum osmotic power density as high as 5.85 kW m -2 can be generated along with a conversion efficiency of 26.3% achieved for a single alumina nanopore at pH 3.5 under a 1000-fold concentration ratio. Using the rigorous model with considering the surface equilibrium reactions on the pore wall, it is proved that these counterintuitive surface-charge-dependent NSGP behaviors result from the pH-dependent ion concentration polarization effect, which yields the degradation in effective concentration ratio across the nanopore. These findings provide significant insight for the design of next-generation, high-performance NSGP devices. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. 40 CFR 98.301 - Reporting threshold.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 22 2012-07-01 2012-07-01 false Reporting threshold. 98.301 Section 98.301 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED... threshold. (a) You must report GHG emissions from an electric power system if the total nameplate capacity...

  14. Variable-Threshold Threshold Elements,

    DTIC Science & Technology

    A threshold element is a mathematical model of certain types of logic gates and of a biological neuron. Much work has been done on the subject of... threshold elements with fixed thresholds; this study concerns itself with elements in which the threshold may be varied, variable- threshold threshold ...elements. Physical realizations include resistor-transistor elements, in which the threshold is simply a voltage. Variation of the threshold causes the

  15. Two-Electron Correlations in e+H-->e+e+p Near Threshold

    NASA Astrophysics Data System (ADS)

    Kato, Daiji; Watanabe, Shinichi

    1995-03-01

    We present an ab initio calculation of the ionization cross section of atomic hydrogen near threshold with precision that compares excellently with the Shah-Elliot-Gilbody experiment [J. Phys. B 20, 3501 (1987)]. This fills the gap between theory and experiment down to 0.1 a.u. above threshold, complementing the recent spectacular work of Bray and Stelbovics [Phys. Rev. Lett. 70, 746 (1993)]. The angular momentum distributions of the secondary electron display an evolution in correlation patterns toward the threshold.

  16. Apolipoprotein L1 confers pH-switchable ion permeability to phospholipid vesicles.

    PubMed

    Bruno, Jonathan; Pozzi, Nicola; Oliva, Jonathan; Edwards, John C

    2017-11-03

    Apolipoprotein L1 (ApoL1) is a human serum protein conferring resistance to African trypanosomes, and certain ApoL1 variants increase susceptibility to some progressive kidney diseases. ApoL1 has been hypothesized to function like a pore-forming colicin and has been reported to have permeability effects on both intracellular and plasma membranes. Here, to gain insight into how ApoL1 may function in vivo , we used vesicle-based ion permeability, direct membrane association, and intrinsic fluorescence to study the activities of purified recombinant ApoL1. We found that ApoL1 confers chloride-selective permeability to preformed phospholipid vesicles and that this selectivity is strongly pH-sensitive, with maximal activity at pH 5 and little activity above pH 7. When ApoL1 and lipid were allowed to interact at low pH and were then brought to neutral pH, chloride permeability was suppressed, and potassium permeability was activated. Both chloride and potassium permeability linearly correlated with the mass of ApoL1 in the reaction mixture, and both exhibited lipid selectivity, requiring the presence of negatively charged lipids for activity. Potassium, but not chloride, permease activity required the presence of calcium ions in both the association and activation steps. Direct assessment of ApoL1-lipid associations confirmed that ApoL1 stably associates with phospholipid vesicles, requiring low pH and the presence of negatively charged phospholipids for maximal binding. Intrinsic fluorescence of ApoL1 supported the presence of a significant structural transition when ApoL1 is mixed with lipids at low pH. This pH-switchable ion-selective permeability may explain the different effects of ApoL1 reported in intracellular and plasma membrane environments. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.

  17. Energy exchange dynamics across L-H transitions in NSTX

    NASA Astrophysics Data System (ADS)

    Diallo, A.; Banerjee, S.; Zweben, S. J.; Stoltzfus-Dueck, T.

    2017-06-01

    We studied the energy exchange dynamics across the low-to-high-confinement (L-H) transition in NSTX discharges using the gas-puff imaging (GPI) diagnostic. The investigation focused on the energy exchange between flows and turbulence to help clarify the mechanism of the L-H transition. We applied this study to three types of heating schemes, including a total of 17 shots from the NSTX 2010 campaign run. Results show that the edge fluctuation characteristics (fluctuation levels, radial and poloidal correlation lengths) measured using GPI do not vary just prior to the H-mode transition, but change after the transition. Using a velocimetry approach (orthogonal-dynamics programming), velocity fields of a 24× 30 cm GPI view during the L-H transition were obtained with good spatial (˜1 cm) and temporal (˜2.5 μs) resolutions. Analysis using these velocity fields shows that the production term is systematically negative just prior to the L-H transition, indicating a transfer from mean flows to turbulence, which is inconsistent with the predator-prey paradigm. Moreover, the inferred absolute value of the production term is two orders of magnitude too small to explain the observed rapid L-H transition. These discrepancies are further reinforced by consideration of the ratio between the kinetic energy in the mean flow to the thermal free energy, which is estimated to be much less than 1, suggesting again that the turbulence depletion mechanism may not play an important role in the transition to the H-mode. Although the Reynolds work therefore appears to be too small to directly deplete the turbulent free energy reservoir, order-of-magnitude analysis shows that the Reynolds stress may still make a non-negligible contribution to the observed poloidal flows.

  18. Determination of irritant threshold concentrations of multiple tree, grass, weed and mould allergens for intradermal testing of horses residing in the southern USA.

    PubMed

    Lane, Martha J; Pucheu-Haston, Cherie M; Kearney, Michael T; Woodward, Michelle

    2017-12-01

    Appropriate allergen threshold concentrations (TCs) for intradermal testing (IDT) have not been established in horses for many pollen and mould allergens. To determine the TCs in non-allergic horses and describe the frequency of late phase reactions for 26 allergens, including trees, grasses, weeds and moulds in horses residing in the southern Unites States. Twenty four clinically normal horses in the southern United States. Threshold concentrations for different allergens were determined using IDT subjective measurements at 30 minutes. Delayed reactions were evaluated at 4 and 24 h. Threshold concentrations (all PNU/mL) were established for eight tree allergens (black willow 1,000, box elder 1,000, live oak 1,000, pecan 2,000, white ash 4,000, red oak 4,000, red mulberry 2,000 and green ash 2,000); two grass allergens (Johnson grass 250 PNU/mL and Kentucky blue grass 500 PNU/mL); two weeds (carelessweed 1,000 PNU/mL, great ragweed 500 PNU/mL) and one mould (Curvularia 8,000 PNU/mL). The TC was not determined due to excessive reactivity at the lowest concentration tested (1,000 PNU/mL) for bahia and perennial rye grass. Eleven other allergens did not meet the criteria to establish a TC when evaluated at 30 min due to lack of positive reactions. Multiple allergens caused positive reactions in ≥10% of horses at 4 h. Reactions at 24 h were rare with the exception of one horse. This study identified intradermal TC for multiple pollen and mould allergens in horses. These values may prove useful for optimizing allergen concentrations for IDT of allergic horses. © 2017 ESVD and ACVD.

  19. Quantitation using a stable isotope dilution assay (SIDA) and thresholds of taste-active pyroglutamyl decapeptide ethyl esters (PGDPEs) in sake.

    PubMed

    Hashizume, Katsumi; Ito, Toshiko; Igarashi, Shinya

    2017-03-01

    A stable isotope dilution assay (SIDA) for two taste-active pyroglutamyl decapeptide ethyl esters (PGDPE1; (pGlu)LFGPNVNPWCOOC 2 H 5 , PGDPE2; (pGlu)LFNPSTNPWCOOC 2 H 5 ) in sake was developed using deuterated isotopes and high-resolution mass spectrometry. Recognition thresholds of PGDPEs in sake were estimated as 3.8 μg/L for PGDPE1 and 8.1 μg/L for PGDPE2, evaluated using 11 student panelists aged in their twenties. Quantitated concentrations in 18 commercial sake samples ranged from 0 to 27 μg/L for PGDPE1 and from 0 to 202 μg/L for PGDPE2. The maximum levels of PGDPE1 and PGDPE2 in the sake samples were approximately 8 and 25 times higher than the estimated recognition thresholds, respectively. The results indicated that PGDPEs may play significant sensory roles in the sake. The level of PGDPEs in unpasteurized sake samples decreased during storage for 50 days at 6 °C, suggesting PGDPEs may be enzymatically decomposed.

  20. Renewable energy powered membrane technology: Impact of pH and ionic strength on fluoride and natural organic matter removal.

    PubMed

    Owusu-Agyeman, Isaac; Shen, Junjie; Schäfer, Andrea Iris

    2018-04-15

    Real water pH and ionic strength vary greatly, which influences the performance of membrane processes such as nanofiltration (NF) and reverse osmosis (RO). Systematic variation of pH (3-12) and ionic strength (2-10g/L as total dissolved solids (TDS)) was undertaken with a real Tanzanian water to investigate how water quality affects retention mechanisms of fluoride (F) and natural organic matter (NOM). An autonomous solar powered NF/RO system driven by a solar array simulator was supplied with constant power from a generator. An open NF (NF270) and a brackish water RO (BW30) membrane were used. A surface water with a very high F (59.7mg/L) and NOM (110mgC/L) was used. Retention of F by NF270 was <20% at pH <6, increased to 40% at pH6, and 60-70% at pH7-12, indicating a dominance of charge repulsion while being ineffective in meeting the guideline of 1.5mg/L. Increase in ionic strength led to a significant decline in retention of F (from 70 to 50%) and electrical conductivity (from 60 to 10%) by NF270, presumably due to charge screening. In contrast, BW30 retained about 50% of F at pH3, >80% at pH4, and about 99% at pH >5, due to the smaller pore size and hence a more dominant size exclusion. In consequence, only little impact of ionic strength increase was observed for BW30. The concentration of NOM in permeates of both NF270 and BW30 were typically <2mg/L. This was not affected by pH or ionic strength due to the fact that the bulk of NOM was rejected by both membranes through size exclusion. The research is carried out in the context of providing safe drinking water for rural and remote communities where infrastructure is lacking, and water quality varies significantly. While other studies focus on energy fluctuations, this research emphasises on feed water quality that affects system performance and may alter due to a number of environmental factors. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. 76 FR 68745 - Seneca Power Partners, L.P.

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-07

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL12-6-000] Seneca Power... October 27, 2011, pursuant to sections 206 and 306 of the Federal Power Act, 16 U.S.C. 824e and 825e and..., 18 CFR 385.206, Seneca Power Partners, L.P. (Complainant) filed a complaint against the New York...

  2. Burnout Thresholds and Cross Section of Power MOS Transistors with Heavy Ions

    DTIC Science & Technology

    1990-02-01

    qIIiH I I I II 11 tH HHif- >HO0 A A A Z P4’ 0 ~ 110 U) to o 0 0 100 11100 00 coU IIC W t-3 t 0 1 00 1 1 100 co ol U 4Ji I V I H- IHrqH I I I H r-I A H H...Wo. W to to Hri ottoo4 t) L OL OL OtLO ca P4 H Hx (n U) 0 U) H1- 0 0 0 0 0 0 0 00 IQ rd 0 Hq H HA H H Hq H Hi H- 0 0 0 0 0 0 0 Hi 0 m~ ~ LOz O H H O I...DEVICE: 2N6788 (IRFF12O) MFR: IR PDC: 8440 (2) 0 .1 ........... ... - 1.OE-2 E &1.OE-3 z7 0 S1.OE-5 b 0 1.OE-6 LET=30 1. OL -7....... I11 70 80 90 100

  3. Threshold-free high-power methods for the ontological analysis of genome-wide gene-expression studies

    PubMed Central

    Nilsson, Björn; Håkansson, Petra; Johansson, Mikael; Nelander, Sven; Fioretos, Thoas

    2007-01-01

    Ontological analysis facilitates the interpretation of microarray data. Here we describe new ontological analysis methods which, unlike existing approaches, are threshold-free and statistically powerful. We perform extensive evaluations and introduce a new concept, detection spectra, to characterize methods. We show that different ontological analysis methods exhibit distinct detection spectra, and that it is critical to account for this diversity. Our results argue strongly against the continued use of existing methods, and provide directions towards an enhanced approach. PMID:17488501

  4. THE H α EMISSION OF NEARBY M DWARFS AND ITS RELATION TO STELLAR ROTATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Newton, Elisabeth R.; Irwin, Jonathan; Charbonneau, David

    The high-energy emission from low-mass stars is mediated by the magnetic dynamo. Although the mechanisms by which fully convective stars generate large-scale magnetic fields are not well understood, it is clear that, as for solar-type stars, stellar rotation plays a pivotal role. We present 270 new optical spectra of low-mass stars in the Solar Neighborhood. Combining our observations with those from the literature, our sample comprises 2202 measurements or non-detections of H α emission in nearby M dwarfs. This includes 466 with photometric rotation periods. Stars with masses between 0.1 and 0.6 M {sub ⊙} are well-represented in our sample,more » with fast and slow rotators of all masses. We observe a threshold in the mass–period plane that separates active and inactive M dwarfs. The threshold coincides with the fast-period edge of the slowly rotating population, at approximately the rotation period at which an era of rapid rotational evolution appears to cease. The well-defined active/inactive boundary indicates that H α activity is a useful diagnostic for stellar rotation period, e.g., for target selection for exoplanet surveys, and we present a mass-period relation for inactive M dwarfs. We also find a significant, moderate correlation between L{sub Hα} / L{sub bol} and variability amplitude: more active stars display higher levels of photometric variability. Consistent with previous work, our data show that rapid rotators maintain a saturated value of L{sub Hα} / L {sub bol}. Our data also show a clear power-law decay in L{sub Hα} / L{sub bol} with Rossby number for slow rotators, with an index of −1.7 ± 0.1.« less

  5. Unravelling the dynamical origin of below- and near-threshold harmonic generation of H 2 + in an intense NIR laser field

    DOE PAGES

    Heslar, John; Chu, Shih-I.

    2016-11-24

    Recently, the study of near- and below- threshold regime harmonics as a potential source of intense coherent vacuum-ultraviolet radiation has received considerable attention. However, the dynamical origin of these lower harmonics, particularly for the molecular systems, is less understood and largely unexplored. Here we perform the first fully ab initio and high precision 3D quantum study of the below- and near-threshold harmonic generation of H 2 + molecules in an intense 800-nm near-infrared (NIR) laser field. Furthermore, combining with a synchrosqueezing transform of the quantum time-frequency spectrum and an extended semiclassical analysis, we explore in-depth the roles of various quantummore » trajectories, including short- and long trajectories, multiphoton trajectories, resonance-enhanced trajectories, and multiple rescattering trajectories of the below- and near- threshold harmonic generation processes. Our results shed new light on the dynamical origin of the below- and near-threshold harmonic generation and various quantum trajectories for diatomic molecules for the first time.« less

  6. Universality of next-to-leading power threshold effects for colourless final states in hadronic collisions

    NASA Astrophysics Data System (ADS)

    Del Duca, V.; Laenen, E.; Magnea, L.; Vernazza, L.; White, C. D.

    2017-11-01

    We consider the production of an arbitrary number of colour-singlet particles near partonic threshold, and show that next-to-leading order cross sections for this class of processes have a simple universal form at next-to-leading power (NLP) in the energy of the emitted gluon radiation. Our analysis relies on a recently derived factorisation formula for NLP threshold effects at amplitude level, and therefore applies both if the leading-order process is tree-level and if it is loop-induced. It holds for differential distributions as well. The results can furthermore be seen as applications of recently derived next-to-soft theorems for gauge theory amplitudes. We use our universal expression to re-derive known results for the production of up to three Higgs bosons at NLO in the large top mass limit, and for the hadro-production of a pair of electroweak gauge bosons. Finally, we present new analytic results for Higgs boson pair production at NLO and NLP, with exact top-mass dependence.

  7. Threshold-dependent sample sizes for selenium assessment with stream fish tissue

    USGS Publications Warehouse

    Hitt, Nathaniel P.; Smith, David R.

    2015-01-01

    Natural resource managers are developing assessments of selenium (Se) contamination in freshwater ecosystems based on fish tissue concentrations. We evaluated the effects of sample size (i.e., number of fish per site) on the probability of correctly detecting mean whole-body Se values above a range of potential management thresholds. We modeled Se concentrations as gamma distributions with shape and scale parameters fitting an empirical mean-to-variance relationship in data from southwestern West Virginia, USA (63 collections, 382 individuals). We used parametric bootstrapping techniques to calculate statistical power as the probability of detecting true mean concentrations up to 3 mg Se/kg above management thresholds ranging from 4 to 8 mg Se/kg. Sample sizes required to achieve 80% power varied as a function of management thresholds and Type I error tolerance (α). Higher thresholds required more samples than lower thresholds because populations were more heterogeneous at higher mean Se levels. For instance, to assess a management threshold of 4 mg Se/kg, a sample of eight fish could detect an increase of approximately 1 mg Se/kg with 80% power (given α = 0.05), but this sample size would be unable to detect such an increase from a management threshold of 8 mg Se/kg with more than a coin-flip probability. Increasing α decreased sample size requirements to detect above-threshold mean Se concentrations with 80% power. For instance, at an α-level of 0.05, an 8-fish sample could detect an increase of approximately 2 units above a threshold of 8 mg Se/kg with 80% power, but when α was relaxed to 0.2, this sample size was more sensitive to increasing mean Se concentrations, allowing detection of an increase of approximately 1.2 units with equivalent power. Combining individuals into 2- and 4-fish composite samples for laboratory analysis did not decrease power because the reduced number of laboratory samples was compensated for by increased

  8. Estimating background and threshold nitrate concentrations using probability graphs

    USGS Publications Warehouse

    Panno, S.V.; Kelly, W.R.; Martinsek, A.T.; Hackley, Keith C.

    2006-01-01

    Because of the ubiquitous nature of anthropogenic nitrate (NO 3-) in many parts of the world, determining background concentrations of NO3- in shallow ground water from natural sources is probably impossible in most environments. Present-day background must now include diffuse sources of NO3- such as disruption of soils and oxidation of organic matter, and atmospheric inputs from products of combustion and evaporation of ammonia from fertilizer and livestock waste. Anomalies can be defined as NO3- derived from nitrogen (N) inputs to the environment from anthropogenic activities, including synthetic fertilizers, livestock waste, and septic effluent. Cumulative probability graphs were used to identify threshold concentrations separating background and anomalous NO3-N concentrations and to assist in the determination of sources of N contamination for 232 spring water samples and 200 well water samples from karst aquifers. Thresholds were 0.4, 2.5, and 6.7 mg/L for spring water samples, and 0.1, 2.1, and 17 mg/L for well water samples. The 0.4 and 0.1 mg/L values are assumed to represent thresholds for present-day precipitation. Thresholds at 2.5 and 2.1 mg/L are interpreted to represent present-day background concentrations of NO3-N. The population of spring water samples with concentrations between 2.5 and 6.7 mg/L represents an amalgam of all sources of NO3- in the ground water basins that feed each spring; concentrations >6.7 mg/L were typically samples collected soon after springtime application of synthetic fertilizer. The 17 mg/L threshold (adjusted to 15 mg/L) for well water samples is interpreted as the level above which livestock wastes dominate the N sources. Copyright ?? 2006 The Author(s).

  9. Validation of the Dutch version of the Swallowing Quality-of-Life Questionnaire (DSWAL-QoL) and the adjusted DSWAL-QoL (aDSWAL-QoL) using item analysis with the Rasch model: a pilot study.

    PubMed

    Simpelaere, Ingeborg S; Van Nuffelen, Gwen; De Bodt, Marc; Vanderwegen, Jan; Hansen, Tina

    2017-04-07

    The Swallowing Quality-of-Life Questionnaire (SWAL-QoL) is considered the gold standard for assessing health-related QoL in oropharyngeal dysphagia. The Dutch translation (DSWAL-QoL) and its adjusted version (aDSWAL-QoL) have been validated using classical test theory (CTT). However, these scales have not been tested against the Rasch measurement model, which is required to establish the structural validity and objectivity of the total scale and subscale scores. Thus, the purpose of this study was to examine the psychometric properties of these scales using item analysis according to the Rasch model. Item analysis with the Rasch model was performed using RUMM2030 software with previously collected data from a validation study of 108 patients. The assessment included evaluations of overall model fit, reliability, unidimensionality, threshold ordering, individual item and person fits, differential item functioning (DIF), local item dependency (LID) and targeting. The analysis could not establish the psychometric properties of either of the scales or their subscales because they did not fit the Rasch model, and multidimensionality, disordered thresholds, DIF, and/or LID were found. The reliability and power of fit were high for the total scales (PSI = 0.93) but low for most of the subscales (PSI < 0.70). The targeting of persons and items was suboptimal. The main source of misfit was disordered thresholds for both the total scales and subscales. Based on the results of the analysis, adjustments to improve the scales were implemented as follows: disordered thresholds were rescaled, misfit items were removed and items were split for DIF. However, the multidimensionality and LID could not be resolved. The reliability and power of fit remained low for most of the subscales. This study represents the first analyses of the DSWAL-QoL and aDSWAL-QoL with the Rasch model. Relying on the DSWAL-QoL and aDSWAL-QoL total and subscale scores to make conclusions regarding

  10. Two-threshold model for scaling laws of noninteracting snow avalanches

    USGS Publications Warehouse

    Faillettaz, J.; Louchet, F.; Grasso, J.-R.

    2004-01-01

    A two-threshold model was proposed for scaling laws of noninteracting snow avalanches. It was found that the sizes of the largest avalanches just preceding the lattice system were power-law distributed. The proposed model reproduced the range of power-law exponents observe for land, rock or snow avalanches, by tuning the maximum value of the ratio of the two failure thresholds. A two-threshold 2D cellular automation was introduced to study the scaling for gravity-driven systems.

  11. Synthesis and the crystal and molecular structures of (H{sub 3}L . Cl)[CoCl{sub 4}] and H{sub 2}L[CuBr{sub 4}] (L is 2,4,6-Tri(N,N-dimethylamino)methylphenol)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kovalchukova, O. V., E-mail: okovalchukova@mail.ru; Stash, A. I.; Strashnova, S. B.

    2010-05-15

    The complex compounds (H{sub 3}L . Cl)[CoCl{sub 4}] (I) and H{sub 2}L[CuBr{sub 4}] (II), where L is 2,4,6-tri(N,N-dimethylamino)methylphenol, were isolated in the crystalline state and studied by X-ray diffraction. The organic cations were found to be outer-sphere ligands. All three nitrogen atoms of the tertiary amino groups are protonated. In compound I, the H{sub 3}L{sup 3+} cation exists as the cis tautomer. In compound II, the H{sub 2}L{sup 2+} dication exists as the trans isomer. In the crystal structure, the dications are arranged in layers via hydrogen bonds.

  12. Validation of a novel wearable, wireless technology to estimate oxygen levels and lactate threshold power in the exercising muscle.

    PubMed

    Farzam, Parisa; Starkweather, Zack; Franceschini, Maria A

    2018-04-01

    There is a growing interest in monitoring muscle oxygen saturation (SmO 2 ), which is a localized measure of muscle oxidative metabolism and can be acquired continuously and noninvasively using near-infrared spectroscopy (NIRS) methods. Most NIRS systems are cumbersome, expensive, fiber coupled devices, with use limited to lab settings. A novel, low cost, wireless, wearable has been developed for use in athletic training. In this study, we evaluate the advantages and limitations of this new simple continuous-wave (CW) NIRS device with respect to a benchtop, frequency-domain near-infrared spectroscopy (FDNIRS) system. Oxygen saturation and hemoglobin/myoglobin concentration in the exercising muscles of 17 athletic individuals were measured simultaneously with the two systems, while subjects performed an incremental test on a stationary cycle ergometer. In addition, blood lactate concentration was measured at the end of each increment with a lactate analyzer. During exercise, the correlation coefficients of the SmO 2 and hemoglobin/myoglobin concentrations between the two systems were over 0.70. We also found both systems were insensitive to the presence of thin layers of varying absorption, mimicking different skin colors. Neither system was able to predict the athletes' lactate threshold power accurately by simply using SmO 2 thresholds. Instead, the proprietary software of the wearable device was able to predict the athletes' lactate threshold power within half of one power increment of the cycling test. These results indicate this novel wearable device may provide a physiological indicator of athlete's exertion. © 2018 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  13. Soft-solution route to ZnO nanowall array with low threshold power density

    NASA Astrophysics Data System (ADS)

    Jang, Eue-Soon; Chen, Xiaoyuan; Won, Jung-Hee; Chung, Jae-Hun; Jang, Du-Jeon; Kim, Young-Woon; Choy, Jin-Ho

    2010-07-01

    ZnO nanowall array (ZNWA) has been directionally grown on the buffer layer of ZnO nanoparticles dip-coated on Si-wafer under a soft solution process. Nanowalls on substrate are in most suitable shape and orientation not only as an optical trap but also as an optical waveguide due to their unique growth habit, V[011¯0]≫V[0001]≈V[0001¯]. Consequently, the stimulated emission at 384 nm through nanowalls is generated by the threshold power density of only 25 kW/cm2. Such UV lasing properties are superior to those of previously reported ZnO nanorod arrays. Moreover, there is no green (defect) emission due to the mild procedure to synthesize ZNWA.

  14. ASASSN-16ae: A POWERFUL WHITE-LIGHT FLARE ON AN EARLY-L DWARF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmidt, Sarah J.; Shappee, Benjamin J.; Seibert, Mark

    2016-09-10

    We report the discovery and classification of SDSS J053341.43+001434.1 (SDSS0533), an early-L dwarf first discovered during a powerful Δ V< −11 magnitude flare observed as part of the ASAS-SN survey. Optical and infrared spectroscopy indicate a spectral type of L0 with strong H α emission and a blue NIR spectral slope. Combining the photometric distance, proper motion, and radial velocity of SDSS0533 yields three-dimensional velocities of ( U , V , W ) = (14 ± 13, −35 ± 14, −94 ± 22) km s{sup −1}, indicating that it is most likely part of the thick disk population and probablymore » old. The three detections of SDSS0533 obtained during the flare are consistent with a total V -band flare energy of at least 4.9 × 10{sup 33} erg (corresponding to a total thermal energy of at least E {sub tot} > 3.7 × 10{sup 34} erg), placing it among the strongest detected M dwarf flares. The presence of this powerful flare on an old L0 dwarf may indicate that stellar-type magnetic activity persists down to the end of the main sequence and on older ML transition dwarfs.« less

  15. 1H NMR determination of beta-N-methylamino-L-alanine (L-BMAA) in environmental and biological samples.

    PubMed

    Moura, Sidnei; Ultramari, Mariah de Almeida; de Paula, Daniela Mendes Louzada; Yonamine, Mauricio; Pinto, Ernani

    2009-04-01

    A nuclear magnetic resonance (1H NMR) method for the determination of beta-N-methylamino-L-alanine (L-BMAA) in environmental aqueous samples was developed and validated. L-BMAA is a neurotoxic modified amino acid that can be produced by cyanobacteria in aqueous environments. This toxin was extracted from samples by means of solid-phase extraction (SPE) and identified and quantified by 1H NMR without further derivatization steps. The lower limit of quantification (LLOQ) was 5 microg/mL. Good inter and intra-assay precision was also observed (relative standard deviation <8.5%) with the use of 4-nitro-DL-phenylalanine as an internal standard (IS). This method of 1H NMR analysis is not time consuming and can be readily utilized to monitor L-BMAA and confirm its presence in environmental and biological samples.

  16. Triple Photoionization of Neon and Argon Near Threshold

    NASA Astrophysics Data System (ADS)

    Bluett, Jaques B.; Lukić, Dragan; Sellin, Ivan A.; Whitfield, Scott B.; Wehlitz, Ralf

    2003-05-01

    The threshold behavior of the triple ionization cross-section of neon and argon was investigated using monochromatized synchrotron radiation and ion time-of-flight spectrometry. The Ne^3+ and Ar^3+ cross-sections are found to follow the Wannier power law(G.H. Wannier, Phys. Rev. 90), 817 (1953). consistent with a Wannier exponent of 2.162 predicted by theory. This is also consistent with the findings of Samson and Angel(J.A.R. Samson and G.C. Angel, Phys. Lett. 61), 1584 (1988). for the case of Ne. In the case of argon we find a much shorter range of validity than for neon.

  17. [Study of setting of ventilator volume tidal and airway pressure alarm threshold with continuous extra-sternum heart compression in cardiopulmonary resuscitation].

    PubMed

    Luo, Jian-yu; Wang, Xiao-yuan; Cai, Tian-bin; Jiang, Wen-fang

    2013-02-01

    To investigate the setting of ventilator volume tidal (VT) and airway pressure alarm threshold during cardiopulmonary resuscitation (CPR) by continuous extra-sternum heart compression. Forty cases with respiration and cardiac arrest in the department of critical care medicine were randomly divided into low VT ventilation group and conventional VT group. Both groups were given the volume control mode. In the low VT ventilation group, VT was set on 6 - 7 ml/kg, and high pressure alarm threshold was adjusted to 60 cm H2O by the conventional 40 cm H2O during CPR. In the conventional VT group, VT and high pressure alarm threshold were set at 8 - 12 ml/kg and 40 cm H2O, respectively. Real-time actual VT, peak inspiratory pressure (PIP), and arterial blood gas test, blood lactic acid at 10 minutes and 30 minutes after CPR were observed. At 10 minutes after CPR, in the low VT ventilation group, arterial blood pH, arterial partial pressure of oxygen (PaO2), arterial partial pressure of carbon dioxide (PaCO2), HCO3(-), arterial oxygen saturation (SaO2) and blood lactic acid were better as compared with those in the conventional VT ventilation group (pH: 7.21±0.09 vs. 7.13±0.07, PaO2: 45.35±5.92 mm Hg vs. 40.70±4.70 mm Hg, PaCO2: 57.10±7.59 mm Hg vs. 61.60±5.47 mm Hg, HCO3(-): 18.50±3.50 mmol/L vs. 14.75±2.65 mmol/L, SaO2: 0.796±0.069 vs. 0.699±0.066, blood lactic acid: 7.07±1.60 mmol/L vs. 8.13±1.56 mmol/L, all P<0.05). The success rate of resuscitation in the low VT ventilation group was higher than that of the conventional VT ventilation group (45% vs. 15%, P<0.05), and PIP (cm H2O) of low VT ventilation group was lower than that of the conventional VT group (37.25±7.99 cm H2O vs. 42.70±7.40 cm H2O, P<0.05). In all the patients in both groups barotrauma did not occur. The strategy of low ventilator VT (6 - 7 ml/kg) with appropriate elevation of airway pressure alarm threshold was better than that of conventional ventilation setting, with no increase in

  18. H2CN+ and H2CNH+: New insight into the structure and dynamics from mass-selected threshold photoelectron spectra

    NASA Astrophysics Data System (ADS)

    Holzmeier, Fabian; Lang, Melanie; Hader, Kilian; Hemberger, Patrick; Fischer, Ingo

    2013-06-01

    In this paper, we reinvestigate the photoionization of nitrogen containing reactive intermediates of the composition H2CN and H2CNH, molecules of importance in astrochemistry and biofuel combustion. In particular, H2CN is also of considerable interest to theory, because of its complicated potential energy surface. The species were generated by flash pyrolysis, ionized with vacuum ultraviolet synchrotron radiation, and studied by mass-selected threshold photoelectron (TPE) spectroscopy. In the mass-selected TPE-spectrum of m/z = 28, contributions of all four isomers of H2CN were identified. The excitation energy to the triplet cation of the methylene amidogen radical H2CN was determined to be 12.32 eV. Considerable activity in the C-N mode of the cation is visible. Furthermore, we derived values for excitation into the triplet cations of 11.72 eV for cis-HCNH, 12.65 eV for trans-HCNH, and 11.21 eV for H2NC. The latter values are probably accurate to within one vibrational quantum. The spectrum features an additional peak at 10.43 eV that corresponds to excitation into the C2v-symmetric H2CN+. As this structure constitutes a saddle point, the peak is assigned to an activated complex on the singlet potential energy surface of the cation, corresponding to a hydrogen atom migration. For methanimine, H2CNH, the adiabatic ionization energy IEad was determined to be 9.99 eV and the vibrational structure of the spectrum was analyzed in detail. The uncertainty of earlier values that simply assigned the signal onset to the IEad is thus considerably reduced. The spectrum is dominated by the H-N-C bending mode ν1+ and the rocking mode ν3+. All experimental data were supported by calculations and Franck-Condon simulations.

  19. Chemopreventive effect of chalcone derivative, L2H17, in colon cancer development.

    PubMed

    Xu, Shanmei; Chen, Minxiao; Chen, Wenbo; Hui, Junguo; Ji, Jiansong; Hu, Shuping; Zhou, Jianmin; Wang, Yi; Liang, Guang

    2015-11-09

    Colon cancer is the third most commonly diagnosed cancer and the second leading cause of cancer mortality worldwide. Chalcone and its derivatives are reported to exhibit anti-cancer effects in several cancer cell lines, including colon cancer cells. In addition, chalcones have advantages such as poor interaction with DNA and low risk of mutagenesity. In our previous study, a group of chalcone derivatives were synthesized and exhibited strong anti-inflammatory activities. In this study, we evaluated the anti-cancer effects of the chalcone derivative, L2H17, in colon cancer cells. The cytotoxicities of L2H17 on various colon cancer cell lines were investigated by MTT and clonogenic assay. Cell cycle and apoptosis analysis were performed to evaluate the molecular mechanism of L2H17-mediated inhibition of tumor growth. Also, scratch wound and matrigel invasion experiments were performed to estimate the cell migration and invasion after L2H17 treatment. Finally, we observed the anti-colon cancer effects of L2H17 in vivo. Our data show that compound L2H17 exhibited selective cytotoxic effect on colon cancer cells, via inducing G0/G1 cell cycle arrest and apoptosis in CT26.WT cells. Furthermore, L2H17 treatment decreased cell migration and invasion of CT26.WT cells. In addition, L2H17 possessed marked anti-tumor activity in vivo. The molecular mechanism of L2H17-mediated inhibition of tumor promotion and progression were function through inactivated NF-κB and Akt signaling pathways. All these findings show that L2H17 might be a potential growth inhibitory chalcones derivative for colon cancer cells.

  20. Physics of GAM-initiated L-H transition in a tokamak

    NASA Astrophysics Data System (ADS)

    Askinazi, L. G.; Belokurov, A. A.; Bulanin, V. V.; Gurchenko, A. D.; Gusakov, E. Z.; Kiviniemi, T. P.; Lebedev, S. V.; Kornev, V. A.; Korpilo, T.; Krikunov, S. V.; Leerink, S.; Machielsen, M.; Niskala, P.; Petrov, A. V.; Tukachinsky, A. S.; Yashin, A. Yu; Zhubr, N. A.

    2017-01-01

    Based on experimental observations using the TUMAN-3M and FT-2 tokamaks, and the results of gyrokinetic modeling of the interplay between turbulence and the geodesic acoustic mode (GAM) in these installations, a simple model is proposed for the analysis of the conditions required for L-H transition triggering by a burst of radial electric field oscillations in a tokamak. In the framework of this model, one-dimensional density evolution is considered to be governed by an anomalous diffusion coefficient dependent on radial electric field shear. The radial electric field is taken as the sum of the oscillating term and the quasi-stationary one determined by density and ion temperature gradients through a neoclassical formula. If the oscillating field parameters (amplitude, frequency, etc) are properly adjusted, a transport barrier forms at the plasma periphery and sustains after the oscillations are switched off, manifesting a transition into the high confinement mode with a strong inhomogeneous radial electric field and suppressed transport at the plasma edge. The electric field oscillation parameters required for L-H transition triggering are compared with the GAM parameters observed at the TUMAN-3M (in the discharges with ohmic L-H transition) and FT-2 tokamaks (where no clear L-H transition was observed). It is concluded based on this comparison that the GAM may act as a trigger for the L-H transition, provided that certain conditions for GAM oscillation and tokamak discharge are met.

  1. 76 FR 20655 - American Electric Power Service Corporation v. PJM Interconnection, L.L.C.; Notice of Complaint

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-13

    ... Electric Power Service Corporation v. PJM Interconnection, L.L.C.; Notice of Complaint Take notice that on... complaint against PJM Interconnection, L.L.C. (Respondent), alleging that Schedule 8.1, section D.8 to the PJM Interconnection, L.L.C. Reliability Assurance Agreement is unjust, unreasonable, and unduly...

  2. Trazodone Increases the Respiratory Arousal Threshold in Patients with Obstructive Sleep Apnea and a Low Arousal Threshold

    PubMed Central

    Eckert, Danny J.; Malhotra, Atul; Wellman, Andrew; White, David P.

    2014-01-01

    Study Objectives: The effect of common sedatives on upper airway physiology and breathing during sleep in obstructive sleep apnea (OSA) has been minimally studied. Conceptually, certain sedatives may worsen OSA in some patients. However, sleep and breathing could improve with certain sedatives in patients with OSA with a low respiratory arousal threshold. This study aimed to test the hypothesis that trazodone increases the respiratory arousal threshold in patients with OSA and a low arousal threshold. Secondary aims were to examine the effects of trazodone on upper airway dilator muscle activity, upper airway collapsibility, and breathing during sleep. Design: Patients were studied on 4 separate nights according to a within-subjects cross-over design. Setting: Sleep physiology laboratory. Patients: Seven patients with OSA and a low respiratory arousal threshold. Interventions: In-laboratory polysomnograms were obtained at baseline and after 100 mg of trazodone was administered, followed by detailed overnight physiology experiments under the same conditions. During physiology studies, continuous positive airway pressure was transiently lowered to measure arousal threshold (negative epiglottic pressure prior to arousal), dilator muscle activity (genioglossus and tensor palatini), and upper airway collapsibility (Pcrit). Measurements and Results: Trazodone increased the respiratory arousal threshold by 32 ± 6% (-11.5 ± 1.4 versus -15.3 ± 2.2 cmH2O, P < 0.01) but did not alter the apnea-hypopnea index (39 ± 12 versus 39 ± 11 events/h sleep, P = 0.94). Dilator muscle activity and Pcrit also did not systematically change with trazodone. Conclusions: Trazodone increases the respiratory arousal threshold in patients with obstructive sleep apnea and a low arousal threshold without major impairment in dilator muscle activity or upper airway collapsibility. However, the magnitude of change in arousal threshold was insufficient to overcome the compromised upper airway

  3. Trazodone increases the respiratory arousal threshold in patients with obstructive sleep apnea and a low arousal threshold.

    PubMed

    Eckert, Danny J; Malhotra, Atul; Wellman, Andrew; White, David P

    2014-04-01

    The effect of common sedatives on upper airway physiology and breathing during sleep in obstructive sleep apnea (OSA) has been minimally studied. Conceptually, certain sedatives may worsen OSA in some patients. However, sleep and breathing could improve with certain sedatives in patients with OSA with a low respiratory arousal threshold. This study aimed to test the hypothesis that trazodone increases the respiratory arousal threshold in patients with OSA and a low arousal threshold. Secondary aims were to examine the effects of trazodone on upper airway dilator muscle activity, upper airway collapsibility, and breathing during sleep. Patients were studied on 4 separate nights according to a within-subjects cross-over design. Sleep physiology laboratory. Seven patients with OSA and a low respiratory arousal threshold. In-laboratory polysomnograms were obtained at baseline and after 100 mg of trazodone was administered, followed by detailed overnight physiology experiments under the same conditions. During physiology studies, continuous positive airway pressure was transiently lowered to measure arousal threshold (negative epiglottic pressure prior to arousal), dilator muscle activity (genioglossus and tensor palatini), and upper airway collapsibility (Pcrit). Trazodone increased the respiratory arousal threshold by 32 ± 6% (-11.5 ± 1.4 versus -15.3 ± 2.2 cmH2O, P < 0.01) but did not alter the apnea-hypopnea index (39 ± 12 versus 39 ± 11 events/h sleep, P = 0.94). Dilator muscle activity and Pcrit also did not systematically change with trazodone. Trazodone increases the respiratory arousal threshold in patients with obstructive sleep apnea and a low arousal threshold without major impairment in dilator muscle activity or upper airway collapsibility. However, the magnitude of change in arousal threshold was insufficient to overcome the compromised upper airway anatomy in these patients.

  4. Threshold groundwater ages and young water fractions estimated from 3H, 3He, and 14C

    NASA Astrophysics Data System (ADS)

    Kirchner, James; Jasechko, Scott

    2016-04-01

    It is widely recognized that a water sample taken from a running stream is not described by a single age, but rather by a distribution of ages. It is less widely recognized that the same principle holds true for groundwaters, as indicated by the commonly observed discordances between model ages obtained from different tracers (e.g., 3H vs 14C) in the same sample. Water age distributions are often characterized by their mean residence times (MRT's). However, MRT estimates are highly uncertain because they depend on the shape of the assumed residence time distribution (in particular on the thickness of the long-time tail), which is difficult or impossible to constrain with data. Furthermore, because MRT's are typically nonlinear functions of age tracer concentrations, they are subject to aggregation bias. That is, MRT estimates derived from a mixture of waters with different ages (and thus different tracer concentrations) will systematically underestimate the mixture's true mean age. Here, building on recent work with stable isotope tracers in surface waters [1-3], we present a new framework for using 3H, 3He and 14C to characterize groundwater age distributions. Rather than describing groundwater age distributions by their MRT, we characterize them by the fraction of the distribution that is younger or older than a threshold age. The threshold age that separates "young" from "old" water depends on the characteristics of the specific tracer, including its history of atmospheric inputs. Our approach depends only on whether a given slice of the age distribution is younger or older than the threshold age, but not on how much younger or older it is. Thus our approach is insensitive to the tails of the age distribution, and is therefore relatively unaffected by uncertainty in the distribution's shape. Here we show that concentrations of 3H, 3He, and 14C are almost linearly related to the fractions of water that are younger or older than specified threshold ages. These

  5. Initial analyses of the relationship between 'Thresholds' of toxicity for individual chemicals and 'Interaction Thresholds' for chemical mixtures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Raymond S.H.; Dennison, James E.

    2007-09-01

    The inter-relationship of 'Thresholds' between chemical mixtures and their respective component single chemicals was studied using three sets of data and two types of analyses. Two in vitro data sets involve cytotoxicity in human keratinocytes from treatment of metals and a metal mixture [Bae, D.S., Gennings, C., Carter, Jr., W.H., Yang, R.S.H., Campain, J.A., 2001. Toxicological interactions among arsenic, cadmium, chromium, and lead in human keratinocytes. Toxicol. Sci. 63, 132-142; Gennings, C., Carter, Jr., W.H., Campain, J.A., Bae, D.S., Yang, R.S.H., 2002. Statistical analysis of interactive cytotoxicity in human epidermal keratinocytes following exposure to a mixture of four metals. J.more » Agric. Biol. Environ. Stat. 7, 58-73], and induction of estrogen receptor alpha (ER-{alpha}) reporter gene in MCF-7 human breast cancer cells by estrogenic xenobiotics [Gennings, C., Carter, Jr., W.H., Carney, E.W., Charles, G.D., Gollapudi, B.B., Carchman, R.A., 2004. A novel flexible approach for evaluating fixed ratio mixtures of full and partial agonists. Toxicol. Sci. 80, 134-150]. The third data set came from PBPK modeling of gasoline and its components in the human. For in vitro cellular responses, we employed Benchmark Dose Software (BMDS) to obtain BMD{sub 01}, BMD{sub 05}, and BMD{sub 10}. We then plotted these BMDs against exposure concentrations for the chemical mixture and its components to assess the ranges and slopes of these BMD-concentration lines. In doing so, we consider certain BMDs to be 'Interaction Thresholds' or 'Thresholds' for mixtures and their component single chemicals and the slope of the line must be a reflection of the potency of the biological effects. For in vivo PBPK modeling, we used 0.1x TLVs, TLVs, and 10x TLVs for gasoline and six component markers as input dosing for PBPK modeling. In this case, the venous blood levels under the hypothetical exposure conditions become our designated 'Interaction Thresholds' or 'Thresholds' for

  6. Comparative Analysis of gO Isoforms Reveals that Strains of Human Cytomegalovirus Differ in the Ratio of gH/gL/gO and gH/gL/UL128-131 in the Virion Envelope

    PubMed Central

    Zhou, Momei; Yu, Qin; Wechsler, Anya

    2013-01-01

    Herpesvirus glycoprotein complex gH/gL provides a core entry function through interactions with the fusion protein gB and can also influence tropism through receptor interactions. The Epstein-Barr virus gH/gL and gH/gL/gp42 serve both functions for entry into epithelial and B cells, respectively. Human cytomegalovirus (HCMV) gH/gL can be bound by the UL128-131 proteins or gO. The phenotypes of gO and UL128-131 mutants suggest that gO-gH/gL interactions are necessary for the core entry function on all cell types, whereas the binding of UL128-131 to gH/gL likely relates to a distinct receptor-binding function for entry into some specific cell types (e.g., epithelial) but not others (e.g., fibroblasts and neurons). There are at least eight isoforms of gO that differ by 10 to 30% of amino acids, and previous analysis of two HCMV strains suggested that some isoforms of gO function like chaperones, disassociating during assembly to leave unbound gH/gL in the virion envelope, while others remain bound to gH/gL. For the current report, we analyzed the gH/gL complexes present in the virion envelope of several HCMV strains, each of which encodes a distinct gO isoform. Results indicate that all strains of HCMV contain stable gH/gL/gO trimers and gH/gL/UL128-131 pentamers and little, if any, unbound gH/gL. TR, TB40/e, AD169, and PH virions contained vastly more gH/gL/gO than gH/gL/UL128-131, whereas Merlin virions contained mostly gH/gL/UL128-131, despite abundant unbound gO remaining in the infected cells. Suppression of UL128-131 expression during Merlin replication dramatically shifted the ratio toward gH/gL/gO. These data suggest that Merlin gO is less efficient than other gO isoforms at competing with UL128-131 for binding to gH/gL. Thus, gO diversity may influence the pathogenesis of HCMV through effects on the assembly of the core versus tropism gH/gL complexes. PMID:23804643

  7. Transport modeling of L- and H-mode discharges with LHCD on EAST

    NASA Astrophysics Data System (ADS)

    Li, M. H.; Ding, B. J.; Imbeaux, F.; Decker, J.; Zhang, X. J.; Kong, E. H.; Zhang, L.; Wei, W.; Shan, J. F.; Liu, F. K.; Wang, M.; Xu, H. D.; Yang, Y.; Peysson, Y.; Basiuk, V.; Artaud, J.-F.; Yuynh, P.; Wan, B. N.

    2013-04-01

    High-confinement (H-mode) discharges with lower hybrid current drive (LHCD) as the only heating source are obtained on EAST. In this paper, an empirical transport model of mixed Bohm/gyro-Bohm for electron and ion heat transport was first calibrated against a database of 3 L-mode shots on EAST. The electron and ion temperature profiles are well reproduced in the predictive modeling with the calibrated model coupled to the suite of codes CRONOS. CRONOS calculations with experimental profiles are also performed for electron power balance analysis. In addition, the time evolutions of LHCD are calculated by the C3PO/LUKE code involving current diffusion, and the results are compared with experimental observations.

  8. Toxicological effects, mechanisms, and implied toxicity thresholds in the roots of Vicia faba L. seedlings grown in copper-contaminated soil.

    PubMed

    Xu, Xianghua; Huang, Zhicheng; Wang, Chengrun; Zhong, Li; Tian, Yuan; Li, Dongdong; Zhang, Gaojian; Shi, Jian

    2015-09-01

    Copper (Cu) contamination has become a global concern because of industrial, agricultural, and other anthropogenic activities. In the present experiments, the toxicological effects, mechanisms, and potential toxicity thresholds were investigated in the roots of Vicia faba L. seedlings that were cultivated in Cu-amended soils (0, 6.25, 12.5, 25, 50, 100, 200, 400, and 600 mg kg(-1)) for 20 days, based on an analysis of the soil physicochemical properties, native Cu, available Cu, and root-enriched Cu contents. The superoxide dismutase (SOD), ascorbate peroxidase (APX), and guaiacol peroxidase (POD) isozymes and activities, as well as glutathione (GSH) and heat shock protein 70 (HSP70), changed like biphasic dose-response curves, cooperating to control the redox homeostasis. The APX and POD enzymes exhibited enhanced activities and became H2O2 scavengers primarily when the catalase (CAT) activities tended to decrease. Endoprotease (EP) isozymes and activities might be enhanced to degrade carbonylated proteins and alleviate metabolic disturbance in the roots. Additionally, HSP70 may not be suitable as a biomarker for relatively higher soil Cu concentrations and relatively longer exposure times for the roots. As a result, the isozymes and activities of SOD, CAT, and EP, as well as GSH, can be adopted as the most sensitive biomarkers. The toxicity threshold is estimated as 0.76-1.21 mg kg(-1) of available Cu in the soils or 25.04-36.65 μg Cu g(-1) dry weights (DW) in the roots.

  9. Calcifications valvulaires chez l'hémodialysé au Maroc

    PubMed Central

    Noto-Kadou-Kaza, Béfa; Abouamrane, Lalla Meryam; Mtiou, Naoufal; El Khaya, Selma; Zamd, Mohamed; Medkouri, Ghislaine; Bengahanem, Mohamed Gharbi; Ramdani, Benyounes

    2016-01-01

    Introduction Les calcifications valvulaires constituent une des complications cardiovasculaires majeures de l'hémodialysé de par sa prévalence et son caractère prédictif de morbidité et de mortalité. De nombreux facteurs de risque sont à l'origine de ces calcifications. Le but de notre étude est d’évaluer à la fois la prévalence des calcifications valvulaires chez nos patients hémodialysés ainsi que leurs facteurs de risque. Méthodes Il s'agissait d'une étude transversale monocentrique, descriptive et analytique, ayant inclus 111 patients adultes hémodialysés depuis plus de 6 mois au centre d'hémodialyse du CHU Ibn Rochd de Casablanca et qui ont eu à bénéficier d'une ETT durant l'année 2013. Résultats L’âge moyen de nos patients était de 44 ± 14 ans. L'ancienneté moyenne en hémodialyse était de 146 ± 80 mois. La pression artérielle moyenne était de 123 ± 23 mmHg pour la systolique et de 72 ± 13 mmHg pour la diastolique, la PTHi moyenne de 529±460 pg/ml, la calcémie moyenne de 86±10 mg/l et la phosphatémie moyenne de 40±15 mg/l. La CRP moyenne était de 11±19,8 mg/L. Sur le plan thérapeutique, 96% des patients étaient sous carbonate de calcium, 11% sous 25 OH vitamine D, 55,5% sous 1 hydroxy-vitamine D3. La prévalence des calcifications valvulaires était de 15% avec une localisation valvulaire aortique dans 41,2% et valvulaire mitrale dans 41,2%. En analyse univariée, seule la durée d'hémodialyse semble être associée à la survenue des calcifications avec p = 0,09 proche du seuil de significativité. Conclusion La prévalence des calcifications valvulaires chez nos patients hémodialysés reste élevée même si elle parait relativement moindre comparée aux données de la littérature. Aucun facteur de risque connu n'est apparu significativement associé à ces calcifications. PMID:27642453

  10. Threshold to Transfer Writing Skills from L1 to L2

    ERIC Educational Resources Information Center

    Ito, Fumihiko

    2009-01-01

    Background: It has been hypothesized that L2 (second language) readers are not able to draw on their L1 (first language) reading skills for the successful development of L2 reading skills until they develop a certain proficiency in L2 because a lack of proficiency blocks transfer of L1 reading skills to the reading of L2 texts. This minimum degree…

  11. Calculating the dim light melatonin onset: the impact of threshold and sampling rate.

    PubMed

    Molina, Thomas A; Burgess, Helen J

    2011-10-01

    The dim light melatonin onset (DLMO) is the most reliable circadian phase marker in humans, but the cost of assaying samples is relatively high. Therefore, the authors examined differences between DLMOs calculated from hourly versus half-hourly sampling and differences between DLMOs calculated with two recommended thresholds (a fixed threshold of 3 pg/mL and a variable "3k" threshold equal to the mean plus two standard deviations of the first three low daytime points). The authors calculated these DLMOs from salivary dim light melatonin profiles collected from 122 individuals (64 women) at baseline. DLMOs derived from hourly sampling occurred on average only 6-8 min earlier than the DLMOs derived from half-hourly saliva sampling, and they were highly correlated with each other (r ≥ 0.89, p < .001). However, in up to 19% of cases the DLMO derived from hourly sampling was >30 min from the DLMO derived from half-hourly sampling. The 3 pg/mL threshold produced significantly less variable DLMOs than the 3k threshold. However, the 3k threshold was significantly lower than the 3 pg/mL threshold (p < .001). The DLMOs calculated with the 3k method were significantly earlier (by 22-24 min) than the DLMOs calculated with the 3 pg/mL threshold, regardless of sampling rate. These results suggest that in large research studies and clinical settings, the more affordable and practical option of hourly sampling is adequate for a reasonable estimate of circadian phase. Although the 3 pg/mL fixed threshold is less variable than the 3k threshold, it produces estimates of the DLMO that are further from the initial rise of melatonin.

  12. Soluble Human Cytomegalovirus gH/gL/pUL128-131 Pentameric Complex, but Not gH/gL, Inhibits Viral Entry to Epithelial Cells and Presents Dominant Native Neutralizing Epitopes.

    PubMed

    Loughney, John W; Rustandi, Richard R; Wang, Dai; Troutman, Matthew C; Dick, Lawrence W; Li, Guanghua; Liu, Zhong; Li, Fengsheng; Freed, Daniel C; Price, Colleen E; Hoang, Van M; Culp, Timothy D; DePhillips, Pete A; Fu, Tong-Ming; Ha, Sha

    2015-06-26

    Congenital infection of human cytomegalovirus (HCMV) is one of the leading causes of nongenetic birth defects, and development of a prophylactic vaccine against HCMV is of high priority for public health. The gH/gL/pUL128-131 pentameric complex mediates HCMV entry into endothelial and epithelial cells, and it is a major target for neutralizing antibody responses. To better understand the mechanism by which antibodies interact with the epitopes of the gH/gL/pUL128-131 pentameric complex resulting in viral neutralization, we expressed and purified soluble gH/gL/pUL128-131 pentameric complex and gH/gL from Chinese hamster ovary cells to >95% purity. The soluble gH/gL, which exists predominantly as (gH/gL)2 homodimer with a molecular mass of 220 kDa in solution, has a stoichiometry of 1:1 and a pI of 6.0-6.5. The pentameric complex has a molecular mass of 160 kDa, a stoichiometry of 1:1:1:1:1, and a pI of 7.4-8.1. The soluble pentameric complex, but not gH/gL, adsorbs 76% of neutralizing activities in HCMV human hyperimmune globulin, consistent with earlier reports that the most potent neutralizing epitopes for blocking epithelial infection are unique to the pentameric complex. Functionally, the soluble pentameric complex, but not gH/gL, blocks viral entry to epithelial cells in culture. Our results highlight the importance of the gH/gL/pUL128-131 pentameric complex in HCMV vaccine design and emphasize the necessity to monitor the integrity of the pentameric complex during the vaccine manufacturing process. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  13. Pregnancy plasma glucose levels exceeding the American Diabetes Association thresholds, but below the National Diabetes Data Group thresholds for gestational diabetes mellitus, are related to the risk of neonatal macrosomia, hypoglycaemia and hyperbilirubinaemia.

    PubMed

    Ferrara, A; Weiss, N S; Hedderson, M M; Quesenberry, C P; Selby, J V; Ergas, I J; Peng, T; Escobar, G J; Pettitt, D J; Sacks, D A

    2007-02-01

    Gestational diabetes mellitus (GDM) is a risk factor for perinatal complications. In several countries, the criteria for the diagnosis of GDM have been in flux, the American Diabetes Association (ADA) thresholds recommended in 2000 being lower than those of the National Diabetes Data Group (NDDG) that have been in use since 1979. We sought to determine the extent to which infants of women meeting only the ADA criteria for GDM are at increased risk of neonatal complications. In a multiethnic cohort of 45,245 women who did not meet the NDDG criteria and were not treated for GDM, we conducted nested case-control studies of three complications of GDM that occurred in their infants: macrosomia (birthweight >4,500 g, n = 494); hypoglycaemia (plasma glucose <2.2 mmo/l, n = 488); and hyperbilirubinaemia (serum bilirubin > or =342 micromol/l (20 mg/dl), n = 578). We compared prenatal glucose levels of the mothers of these infants and mothers of 884 control infants. Women with GDM by ADA criteria only (two or more glucose values exceeding the threshold) had an increased risk of having an infant with macrosomia (odds ratio OR = 3.40, 95% CI = 1.55-7.43), hypoglycaemia (OR = 2.61, 95% CI = 0.99-6.92) or hyperbilirubinaemia (OR = 2.22, 95% CI = 0.98-5.04). Glucose levels 1 h after the 100-g glucose challenge that exceeded the ADA threshold were particularly strongly associated with each complication. These results lend support to the ADA recommendations and highlight the importance of the 1-h glucose measurement in a diagnostic test for GDM.

  14. Thermoelectric power study of Ag 7C 6H 14NI 8 material

    NASA Astrophysics Data System (ADS)

    Khalifa, M. M.; EL-Mashri, S. M.; Avasthi, M. N.

    2002-08-01

    Thermoelectric power of the material Ag 7C 6H 14NI 8 has been studied for the first time in the temperature range 20-l00°C. Thermopower versus 1/ T plot comes out to be a straight line and can be represented by the equation -θ=0.15 {10 3}/{T}+0.06 for the material. Heat of transport of Ag + ion in the material is very nearly equal to the activation energy. The work points towards the correctness of the Rice and Roth model. It also shows that the material is ordered.

  15. Cavitation and non-cavitation regime for large-scale ultrasonic standing wave particle separation systems--In situ gentle cavitation threshold determination and free radical related oxidation.

    PubMed

    Johansson, Linda; Singh, Tanoj; Leong, Thomas; Mawson, Raymond; McArthur, Sally; Manasseh, Richard; Juliano, Pablo

    2016-01-01

    We here suggest a novel and straightforward approach for liter-scale ultrasound particle manipulation standing wave systems to guide system design in terms of frequency and acoustic power for operating in either cavitation or non-cavitation regimes for ultrasound standing wave systems, using the sonochemiluminescent chemical luminol. We show that this method offers a simple way of in situ determination of the cavitation threshold for selected separation vessel geometry. Since the pressure field is system specific the cavitation threshold is system specific (for the threshold parameter range). In this study we discuss cavitation effects and also measure one implication of cavitation for the application of milk fat separation, the degree of milk fat lipid oxidation by headspace volatile measurements. For the evaluated vessel, 2 MHz as opposed to 1 MHz operation enabled operation in non-cavitation or low cavitation conditions as measured by the luminol intensity threshold method. In all cases the lipid oxidation derived volatiles were below the human sensory detection level. Ultrasound treatment did not significantly influence the oxidative changes in milk for either 1 MHz (dose of 46 kJ/L and 464 kJ/L) or 2 MHz (dose of 37 kJ/L and 373 kJ/L) operation. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Parallel electron force balance and the L-H transition

    DOE PAGES

    Stoltzfus-Dueck, T.

    2016-05-23

    In one popular paradigm for the L-H transition, energy transfer to the mean flows directly depletes turbulence fluctuation energy, resulting in suppression of the turbulence and a corresponding transport bifurcation. To quantitatively evaluate this mechanism, one must remember that electron parallel force balance couples nonzonal velocity fluctuations with electron pressure fluctuations on rapid timescales, comparable with the electron transit time. For this reason, energy in the nonzonal velocity stays in a fairly fixed ratio to the free energy in electron density fluctuations, at least for frequency scales much slower than electron transit. Furthermore, in order for direct depletion of themore » energy in turbulent fluctuations to cause the L-H transition, energy transfer via Reynolds stress must therefore drain enough energy to significantly reduce the sum of the free energy in nonzonal velocities and electron pressure fluctuations. At low k⊥, the electron thermal free energy is much larger than the energy in nonzonal velocities, posing a stark challenge for this model of the L-H transition.« less

  17. Search for the decay modes B ±→h ±τl

    DOE PAGES

    Lees, J. P.; Poireau, V.; Tisserand, V.; ...

    2012-07-16

    We present a search for the lepton flavor violating decay modes B ±→h ±τl (h=K, π; l=e, μ) using the BABAR data sample, which corresponds to 472×10⁶ BB¯¯¯ pairs. The search uses events where one B meson is fully reconstructed in one of several hadronic final states. Using the momenta of the reconstructed B, h, and l candidates, we are able to fully determine the τ four-momentum. The resulting τ candidate mass is our main discriminant against combinatorial background. We see no evidence for B ±→h ±τl decays and set a 90% confidence level upper limit on each branching fractionmore » at the level of a few times 10⁻⁵.« less

  18. Design and Comparison of Cascaded H-Bridge, Modular Multilevel Converter, and 5-L Active Neutral Point Clamped Topologies for Motor Drive Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marzoughi, Alinaghi; Burgos, Rolando; Boroyevich, Dushan

    This paper presents the design procedure and comparison of converters currently used in medium-voltage high-power motor drive applications. For this purpose, the cascaded H-bridge (CHB), modular multilevel converter (MMC), and five-level active neutral point clamped (5-L ANPC) topologies are targeted. The design is performed using 1.7-kV insulated gate bipolar transistors (IGBTs) for CHB and MMC converters, and utilizing 3.3- and 4.5-kV IGBTs for 5-L ANPC topology as normally done in industry. The comparison is done between the designed converter topologies at three different voltage levels (4.16, 6.9, and 13.8 kV, with only the first two voltage levels in case ofmore » the 5-L ANPC) and two different power levels (3 and 5 MVA), in order to elucidate the dependence of different parameters on voltage and power rating. Finally, the comparison is done from several points of view such as efficiency, capacitive energy storage, semiconductor utilization, parts count (for measure of reliability), and power density.« less

  19. Axisymmetric oscillations at L-H transitions in JET: M-mode

    NASA Astrophysics Data System (ADS)

    Solano, Emilia R.; Vianello, N.; Delabie, E.; Hillesheim, J. C.; Buratti, P.; Réfy, D.; Balboa, I.; Boboc, A.; Coelho, R.; Sieglin, B.; Silburn, S.; Drewelow, P.; Devaux, S.; Dodt, D.; Figueiredo, A.; Frassinetti, L.; Marsen, S.; Meneses, L.; Maggi, C. F.; Morris, J.; Gerasimov, S.; Baruzzo, M.; Stamp, M.; Grist, D.; Nunes, I.; Rimini, F.; Schmuck, S.; Lupelli, I.; Silva, C.; contributors, JET

    2017-02-01

    L to H transition studies at JET have revealed an n  =  0, m  =  1 magnetic oscillation starting immediately at the L to H transition (called M-mode for brevity). While the magnetic oscillation is present a weak ELM-less H-mode regime is obtained, with a clear increase of density and a weak electron temperature pedestal. It is an intermediate state between L and H-mode. In ICRH heated plasmas or low density NBI plasmas the magnetic mode and the pedestal can remain steady (with small oscillations) for the duration of the heating phase, of order 10 s or more. The axisymmetric magnetic oscillation has period ~0.5-2 ms, and poloidal mode number m  =  1: it looks like a pedestal localised up/down oscillation, although it is clearly a natural oscillation of the plasma, not driven by the position control system. Electron cyclotron emission, interferometry, reflectometry and fast Li beam measurements locate the mode in the pedestal region. D α , fast infrared camera and Langmuir probe measurements show that the mode modulates heat and particle fluxes to the target. The mode frequency appears to scale with the poloidal Alfvén velocity, and not with sound speed (i.e. it is not a geodesic acoustic mode). A heuristic model is proposed for the frequency scaling of the mode. We discuss the relationship between the M-mode and other related observations near the L-H transition.

  20. Urine reference intervals for human chorionic gonadotropin (hCG) isoforms by immunoextraction-tandem mass spectrometry to detect hCG use.

    PubMed

    Butch, Anthony W; Ahrens, Brian D; Avliyakulov, Nuraly K

    2017-11-03

    Human chorionic gonadotropin (hCG) stimulates testosterone production by the testicles and can normalize suppressed testosterone concentrations in males following prolonged anabolic steroid use. Because of the potential for abuse by males, hCG is on the World Anti-Doping Agency (WADA) list of prohibited substances. The majority of WADA-accredited laboratories measure urinary hCG using an automated immunoassay. Only immunoassays that recognize the intact alpha and beta heterodimer of hCG (intact hCG) should be used to measure urinary hCG for doping control purposes since intact hCG is the only biologically active molecule. WADA further requires that confirmation testing is performed using an intact hCG immunoassay that is different from the one used in the initial testing procedure or by liquid chromatography-tandem mass spectrometry (LC-MS/MS). In this study we measured the concentration of intact hCG, free β-subunit (hCGβ) and β-subunit core fragment (hCGβcf) in 570, 275, and 256 male urine samples, respectively, by an immunoextraction LC-MS/MS method. Mean concentrations of intact hCG, hCGβ and hCGβcf were 0.04 IU/L, 0.47 pmol/L and 0.16 pmol/L, respectively. The upper reference limits (97.5 th percentile) for intact hCG, hCGβ and hCGβcf were 0.21 IU/L, 0.40 pmol/L, and 1.86 pmol/L, respectively. Based on these data, we recommend a threshold of 1.0 IU/L for intact hCG (false positive rate of <1 in 10 000) for detecting male athletes that dope with hCG. Copyright © 2017 John Wiley & Sons, Ltd.

  1. Direct observations of L-I-H and H-I-L transitions with the X-point reciprocating probe in ASDEX Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Müller, S. H.; Conway, G. D.; Birkenmeier, G.

    A reciprocating Langmuir probe was used to directly measure the behavior of turbulence and flows in the X-point region during transitions between low-(L) and high-confinement (H) mode in ASDEX Upgrade. The probe traverses the divertor horizontally in 140 ms, typically 2–5 cm below the X-point. Toroidal Mach number, density, floating potential (ϕ{sub f}), and electron temperature (T{sub e}) are measured. In the regime accessible to the probe (P{sub inj}<1.5 MW, line-integrated core density <4×10{sup 19} m{sup −2}), the L-H transition features an intermediate phase (I-phase), characterized by limit-cycle oscillations at 0.5–3 kHz [Conway et al., Phys. Rev. Lett. 106, 065001 (2011)]. The probe measurements revealmore » that this pulsing affects both the density and the toroidal Mach number. It is present in both the low-(LFS) and high-field sides (HFS) of the scrape-off layer, while high-amplitude broadband turbulence usually dominates the private-flux region. Profile comparisons between L-mode and I-phase show lower density in pulsing regions and small shifts in T{sub e}, directed oppositely on LFS and HFS, which are compensated by shifts in ϕ{sub f} to yield a surprisingly unchanged plasma potential profile. Directly observed L-I-phase transitions reveal that the onset of the pulsing is preceded by a fast 50% density drop in the HFS X-point region. Back transitions to L-mode occur essentially symmetrically, with the pulsing stopping first, followed by a fast recovery to L-mode density levels in the divertor.« less

  2. Troubles de l'hémostase en réanimation chirurgicale de l'Hôpital Universitaire Joseph Ravoahangy Andrianavalona Antananarivo

    PubMed Central

    Rasoamampianina, Lalaina Elianah; Rafanomezantsoa, Toky Andriamahefa; Rakotondrainibe, Aurélia; Rajaonera, Andriambelo Tovohery; Randriamanantany, Zely Arivelo; Alson, Olivat Rakoto; Raveloson, Nasolotsiry Enintsoa

    2015-01-01

    Les troubles de l'hémostase sont fréquemment observés en réanimation. L'objectif de cette étude est d'en déterminer l'incidence, les étiologies et la prise en charge pour en diminuer le risque de morbi-mortalité. Etude rétrospective sur une période de huit mois en réanimation chirurgicale du CHUA HUJRA. Les dossiers étudiés étaient ceux contenant tous les premiers bilans d'hémostase lors de l'admission du patient en réanimation, avec un âge supérieur à 15 ans. Etaient exclus les dossiers des post opérés (malade ayant subi une intervention chirurgicale). Les dossiers retenus pour l'étude étaient ceux qui ont présenté une ou plusieurs anomalies au niveau du bilan d'hémostase. Cent cinquante-cinq dossiers ont été colligés dont 20,64% ont présenté un trouble de l'hémostase. Les patients de sexe féminin (53,12%) étaient les plus concernés, avec une population âgée en moyenne de 49±19 ans. Trois patients (9,37%) ont présenté une notion de diathèse hémorragique à l'interrogatoire. Les différents troubles de l'hémostase étaient: une diminution du taux de prothrombine (100%), un taux de céphaline activé allongé (78,12%), un international normalized ratio élevé (43,75%) et des thrombopénies (40,62%). Chez 3,12% de ces cas, des accidents hémorragiques ont survenu. La plupart de ces troubles de l'hémostase étaient présents au décours d'hémorragies digestives (46,87%) dont la prise en charge était constituée par l'administration de vitamine K1 (68,75%) et de transfusion de plasma frais congelé (65,62%). D'autres pathologies ont été également incriminées. Une incidence de 15,62% de mortalité a été retrouvée. L'existence des troubles de l'hémostase en réanimation constitue un facteur pronostique imposant un dépistage et une prise en charge précoces et adéquats pour pouvoir en réduire le taux de mortalité. PMID:26848361

  3. Evolution of Edge Pedestal Profiles Over the L-H Transition

    NASA Astrophysics Data System (ADS)

    Sayer, M. S.; Stacey, W. M.; Floyd, J. P.; Groebner, R. J.

    2012-10-01

    The detailed time evolution of thermal diffusivities, electromagnetic forces, pressure gradients, particle pinch and momentum transport frequencies (which determine the diffusion coefficient) have been analyzed during the L-H transition in a DIII-D discharge. Density, temperature, rotation velocity and electric field profiles at times just before and after the L-H transition are analyzed in terms of these quantities. The analysis is based on the fluid particle balance, energy balance, force balance and heat conduction equations, as in Ref. [1], but with much greater time resolution and with account for thermal ion orbit loss. The variation of diffusive and non-diffusive transport over the L-H transition is determined from the variation in the radial force balance (radial electric field, VxB force, and pressure gradient) and the variation in the interpreted diffusive transport coefficients. 6pt [1] W.M. Stacey and R.J. Groebner, Phys. Plasmas 17, 112512 (2010).

  4. Crystal structure of the conserved herpes virus fusion regulator complex gH-gL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chowdary, Tirumala K; Cairns, Tina M; Atanasiu, Doina

    2010-09-13

    Herpesviruses, which cause many incurable diseases, infect cells by fusing viral and cellular membranes. Whereas most other enveloped viruses use a single viral catalyst called a fusogen, herpesviruses, inexplicably, require two conserved fusion-machinery components, gB and the heterodimer gH-gL, plus other nonconserved components. gB is a class III viral fusogen, but unlike other members of its class, it does not function alone. We determined the crystal structure of the gH ectodomain bound to gL from herpes simplex virus 2. gH-gL is an unusually tight complex with a unique architecture that, unexpectedly, does not resemble any known viral fusogen. Instead, wemore » propose that gH-gL activates gB for fusion, possibly through direct binding. Formation of a gB-gH-gL complex is critical for fusion and is inhibited by a neutralizing antibody, making the gB-gH-gL interface a promising antiviral target.« less

  5. Color difference thresholds in dentistry.

    PubMed

    Paravina, Rade D; Ghinea, Razvan; Herrera, Luis J; Bona, Alvaro D; Igiel, Christopher; Linninger, Mercedes; Sakai, Maiko; Takahashi, Hidekazu; Tashkandi, Esam; Perez, Maria del Mar

    2015-01-01

    The aim of this prospective multicenter study was to determine 50:50% perceptibility threshold (PT) and 50:50% acceptability threshold (AT) of dental ceramic under simulated clinical settings. The spectral radiance of 63 monochromatic ceramic specimens was determined using a non-contact spectroradiometer. A total of 60 specimen pairs, divided into 3 sets of 20 specimen pairs (medium to light shades, medium to dark shades, and dark shades), were selected for psychophysical experiment. The coordinating center and seven research sites obtained the Institutional Review Board (IRB) approvals prior the beginning of the experiment. Each research site had 25 observers, divided into five groups of five observers: dentists-D, dental students-S, dental auxiliaries-A, dental technicians-T, and lay persons-L. There were 35 observers per group (five observers per group at each site ×7 sites), for a total of 175 observers. Visual color comparisons were performed using a viewing booth. Takagi-Sugeno-Kang (TSK) fuzzy approximation was used for fitting the data points. The 50:50% PT and 50:50% AT were determined in CIELAB and CIEDE2000. The t-test was used to evaluate the statistical significance in thresholds differences. The CIELAB 50:50% PT was ΔEab  = 1.2, whereas 50:50% AT was ΔEab  = 2.7. Corresponding CIEDE2000 (ΔE00 ) values were 0.8 and 1.8, respectively. 50:50% PT by the observer group revealed differences among groups D, A, T, and L as compared with 50:50% PT for all observers. The 50:50% AT for all observers was statistically different than 50:50% AT in groups T and L. A 50:50% perceptibility and ATs were significantly different. The same is true for differences between two color difference formulas ΔE00 /ΔEab . Observer groups and sites showed high level of statistical difference in all thresholds. Visual color difference thresholds can serve as a quality control tool to guide the selection of esthetic dental materials, evaluate clinical performance, and

  6. 78 FR 26241 - Airworthiness Directives; Diamond Aircraft Industries GmbH Powered Gliders

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-06

    ... Airworthiness Directives; Diamond Aircraft Industries GmbH Powered Gliders AGENCY: Federal Aviation... directive (AD) for certain Diamond Aircraft Industries GmbH Models HK 36 R, HK 36 TS, and HK 36 TTS powered... removing the Model H-36 from the Applicability. This AD was prompted by reports of installation of an...

  7. Structure and dynamics of H2+ near the dissociation threshold: A combined experimental and computational investigation

    NASA Astrophysics Data System (ADS)

    Beyer, Maximilian; Merkt, Frédéric

    2016-12-01

    The pulsed-field-ionization zero-kinetic-energy photoelectron spectrum of H2 has been recorded in the vicinity of the dissociative-ionization threshold following three-photon excitation via selected rotational levels of the B1 Σu+ (v = 19) and H ‾ 1 Σg+ (v = 11) intermediate states. The spectra consist of transitions to bound levels of the X+2 Σg+ state of H2+ with v+ in the range 14-19 and N+ in the range 0-9, of the A+2 Σu+ state with v+ = 0 and N+ = 0-2, and of shape resonances corresponding to the X+(v+ = 17, N+ = 7) and X+(v+ = 18, N+ = 4) quasibound levels. Calculations of the level structure of H2+ have been carried out and the influence of adiabatic, nonadiabatic, relativistic and radiative corrections on the positions of these levels, and in the case of the shape resonances also on their widths, has been investigated. Different methods of calculating the widths and profiles of the shape resonances have been tested for comparison with the experimental observations. Slow oscillations of the dissociative-ionization yield have been observed and reflect, in first approximation, the Franck-Condon factors of the X+, A+ ← H ‾ bound - free transitions.

  8. 76 FR 36914 - Astoria Generating Company, L.P., NRG Power Marketing LLC, Arthur Kill Power LLC, Astoria Gas...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-23

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL11-42-000] Astoria Generating Company, L.P., NRG Power Marketing LLC, Arthur Kill Power LLC, Astoria Gas Turbine Power LLC, Dunkirk Power LLC, Huntley Power LLC, Oswego Harbor Power LLC, TC Ravenswood, LLC, v. New York Independent System Operator, Inc. Notice of Revised...

  9. 76 FR 34692 - Astoria Generating Company, L.P., NRG Power Marketing LLC, Arthur Kill Power LLC, Astoria Gas...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-14

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL11-42-000] Astoria Generating Company, L.P., NRG Power Marketing LLC, Arthur Kill Power LLC, Astoria Gas Turbine Power LLC, Dunkirk Power LLC, Huntley Power LLC, Oswego Harbor Power LLC, TC Ravenswood, LLC; v. New York Independent System Operator, Inc.; Notice of Complaint...

  10. 76 FR 36910 - Astoria Generating Company, L.P., NRG Power Marketing LLC, Arthur Kill Power LLC, Astoria Gas...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-23

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL11-42-000] Astoria Generating Company, L.P., NRG Power Marketing LLC, Arthur Kill Power LLC, Astoria Gas Turbine Power LLC, Dunkirk Power LLC, Huntley Power LLC, Oswego Harbor Power LLC, TC Ravenswood, LLC. v. New York Independent System Operator, Inc.; Notice of Amendment t...

  11. 77 FR 71487 - Airworthiness Directives; Stemme GmbH & Co. KG Powered Sailplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-03

    ... Airworthiness Directives; Stemme GmbH & Co. KG Powered Sailplanes AGENCY: Federal Aviation Administration (FAA... directive (AD) for all Stemme GmbH & Co. KG Models S10, S10-V, and S10-VT powered sailplanes. This AD... damage to the sailplane and/or injury of occupants. Prompted by these findings, Stemme GmbH developed a...

  12. A SEARCH FOR l-C{sub 3}H{sup +} AND l-C{sub 3}H IN Sgr B2(N), Sgr B2(OH), AND THE DARK CLOUD TMC-1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGuire, Brett A.; Carroll, P. Brandon; Loomis, Ryan A.

    2013-09-01

    Pety et al. recently reported the detection of several transitions of an unknown carrier in the Horsehead PDR and attribute them to l-C{sub 3}H{sup +}. Here, we have tested the predictive power of their fit by searching for, and identifying, the previously unobserved J = 1-0 and J = 2-1 transitions of the unknown carrier (B11244) toward Sgr B2(N) in data from the publicly available PRIMOS project. Also presented here are observations of the J = 6-5 and J = 7-6 transitions toward Sgr B2(N) and Sgr B2(OH) using the Barry E. Turner Legacy Survey and results from the Kaifumore » et al. survey of TMC-1. We calculate an excitation temperature and column density of B11244 of {approx}10 K and {approx}10{sup 13} cm{sup -2} in Sgr B2(N) and {approx}79 K with an upper limit of {<=}1.5 Multiplication-Sign 10{sup 13} cm{sup -2} in Sgr B2(OH) and find trace evidence for the cation's presence in TMC-1. Finally, we present spectra of the neutral species in both Sgr B2(N) and TMC-1, and comment on the robustness of the assignment of the detected signals to l-C{sub 3}H{sup +}.« less

  13. hERG blocking potential of acids and zwitterions characterized by three thresholds for acidity, size and reactivity.

    PubMed

    Nikolov, Nikolai G; Dybdahl, Marianne; Jónsdóttir, Svava Ó; Wedebye, Eva B

    2014-11-01

    Ionization is a key factor in hERG K(+) channel blocking, and acids and zwitterions are known to be less probable hERG blockers than bases and neutral compounds. However, a considerable number of acidic compounds block hERG, and the physico-chemical attributes which discriminate acidic blockers from acidic non-blockers have not been fully elucidated. We propose a rule for prediction of hERG blocking by acids and zwitterionic ampholytes based on thresholds for only three descriptors related to acidity, size and reactivity. The training set of 153 acids and zwitterionic ampholytes was predicted with a concordance of 91% by a decision tree based on the rule. Two external validations were performed with sets of 35 and 48 observations, respectively, both showing concordances of 91%. In addition, a global QSAR model of hERG blocking was constructed based on a large diverse training set of 1374 chemicals covering all ionization classes, externally validated showing high predictivity and compared to the decision tree. The decision tree was found to be superior for the acids and zwitterionic ampholytes classes. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Impact of Different Tidal Volume Levels at Low Mechanical Power on Ventilator-Induced Lung Injury in Rats.

    PubMed

    Moraes, Lillian; Silva, Pedro L; Thompson, Alessandra; Santos, Cintia L; Santos, Raquel S; Fernandes, Marcos V S; Morales, Marcelo M; Martins, Vanessa; Capelozzi, Vera L; de Abreu, Marcelo G; Pelosi, Paolo; Rocco, Patricia R M

    2018-01-01

    Tidal volume (V T ) has been considered the main determinant of ventilator-induced lung injury (VILI). Recently, experimental studies have suggested that mechanical power transferred from the ventilator to the lungs is the promoter of VILI. We hypothesized that, as long as mechanical power is kept below a safe threshold, high V T should not be injurious. The present study aimed to investigate the impact of different V T levels and respiratory rates (RR) on lung function, diffuse alveolar damage (DAD), alveolar ultrastructure, and expression of genes related to inflammation [interleukin (IL)-6], alveolar stretch (amphiregulin), epithelial [club cell secretory protein (CC)16] and endothelial [intercellular adhesion molecule (ICAM)-1] cell injury, and extracellular matrix damage [syndecan-1, decorin, and metalloproteinase (MMP)-9] in experimental acute respiratory distress syndrome (ARDS) under low-power mechanical ventilation. Twenty-eight Wistar rats received Escherichia coli lipopolysaccharide intratracheally. After 24 h, 21 animals were randomly assigned to ventilation (2 h) with low mechanical power at three different V T levels ( n = 7/group): (1) V T = 6 mL/kg and RR adjusted to normocapnia; (2) V T = 13 mL/kg; and 3) V T = 22 mL/kg. In the second and third groups, RR was adjusted to yield low mechanical power comparable to that of the first group. Mechanical power was calculated as [(Δ[Formula: see text]/Est, L )/2]× RR (ΔP, L = transpulmonary driving pressure, Est, L = static lung elastance). Seven rats were not mechanically ventilated (NV) and were used for molecular biology analysis. Mechanical power was comparable among groups, while V T gradually increased. ΔP, L and mechanical energy were higher in V T = 22 mL/kg than V T = 6 mL/kg and V T = 13 mL/kg ( p < 0.001 for both). Accordingly, DAD score increased in V T = 22 mL/kg compared to V T = 6 mL/kg and V T = 13 mL/kg [23(18.5-24.75) vs. 16(12-17.75) and 16(13.25-18), p < 0.05, respectively]. V T = 22

  15. Threshold concentration in the nonlinear absorbance law.

    PubMed

    Tolbin, Alexander Yu; Pushkarev, Victor E; Tomilova, Larisa G; Zefirov, Nikolay S

    2017-05-24

    A new nonlinear relationship of the absorption coefficient with the concentration was proposed, allowing the calculation of the threshold concentration, which shows that there is a deviation from the Beer-Lambert law. The nonlinear model was successfully tested on a stable dimeric phthalocyanine ligand of J-type in solvents with different polarity. It was shown that deviation from the linearity is connected with a specific association of the macrocyclic molecules, which, in the case of non-polar solvents, leads to the formation of H-aggregates composed of J-type dimeric molecules. The aggregation number was estimated to be less than 1.5, which has allowed us to conduct a series of analytical experiments in a wide range of concentrations (1 × 10 -6 -5 × 10 -4 mol L -1 ).

  16. Comparison of ventilation threshold and heart rate deflection point in fast and standard treadmill test protocols.

    PubMed

    Vucetić, Vlatko; Sentija, Davor; Sporis, Goran; Trajković, Nebojsa; Milanović, Zoran

    2014-06-01

    The purpose of this study was to compare two methods for determination of anaerobic threshold from two different treadmill protocols. Forty-eight Croatian runners of national rank (ten sprinters, fifteen 400-m runners, ten middle distance runners and thirteen long distance runners), mean age 21.7 +/- 5.1 years, participated in the study. They performed two graded maximal exercise tests on a treadmill, a standard ramp treadmill test (T(SR), speed increments of 1 km x h(-1) every 60 seconds) and a fast ramp treadmill test (T(FR), speed increments of 1 km x h(-1) every 30 seconds) to determine and compare the parameters at peak values and at heart rate at the deflection point (HR(DP)) and ventilation threshold (VT). There were no significant differences between protocols (p > 0.05) for peak values of oxygen uptake (VO(2max), 4.48 +/- 0.43 and 4.44 +/- 0.45 L x min(-1)), weight related VO(2max) (62.5 +/- 6.2 and 62.0 +/- 6.0 mL x kg(-1) x min(-1)), pulmonary ventilation (VE(max), 163.1 +/- 18.7 and 161.3 +/- 19.9 L x min(-1)) and heart rate (HR(max), 192.3 +/- 8.5 and 194.4 +/- 8.7 bpm) (T(FR) and T(SR), respectively). Moreover, no significant differences between T(FR) and T(SR) where found for VT and HR(DP) when expressed as VO2 and HR. However, there was a significant effect of ramp slope on running speed at VO(2max) and at the anaerobic threshold (AnT), independent of the method used (VT: 16.0 +/- 2.2 vs 14.9 +/- 2.2 km x h(-1);HR(DP): 16.5 +/- 1.9 vs 14.9 +/- 2.0 km x h(-1) for T(FR) and T(SR) respectively). Linear regression analysis revealed high between-test and between-method correlations for VO2, HR and running speed parameters (r = 0.78-0.89, p < 0.01). The present study has indicated that the VT and HR(DP) for running (VO2, ventilation, and heart rate at VT/HR(DP)) are independent of test protocol, while there is a significant effect of ramp slope on VT and HR(DP) when expressed as running speed. Moreover, this study demonstrates that the point of deflection

  17. 43. FLOOR PLAN OF POWER HOUSE, EXHIBIT L, SANTA ANA ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    43. FLOOR PLAN OF POWER HOUSE, EXHIBIT L, SANTA ANA RIVER NO. 2 PROJECT, APR. 30, 1945. SCE drawing no. 523643 (sheet no. 14; for filing with Federal Power Commission). - Santa Ana River Hydroelectric System, SAR-2 Powerhouse, Redlands, San Bernardino County, CA

  18. 44. SECTIONS OF POWER HOUSE, EXHIBIT L, SANTA ANA RIVER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    44. SECTIONS OF POWER HOUSE, EXHIBIT L, SANTA ANA RIVER NO. 2 PROJECT, APR. 30, 1945. SCE drawing no. 523644 (sheet no. 15; for filing with Federal Power Commission). - Santa Ana River Hydroelectric System, SAR-2 Powerhouse, Redlands, San Bernardino County, CA

  19. 55. CROSS SECTION OF POWER HOUSE, EXHIBIT L, SANTA ANA ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    55. CROSS SECTION OF POWER HOUSE, EXHIBIT L, SANTA ANA RIVER NO. 1 PROJECT, APR. 30, 1945. SCE drawing no. 523199 (sheet no. 9, for filing with Federal Power Commission). - Santa Ana River Hydroelectric System, SAR-1 Powerhouse, Redlands, San Bernardino County, CA

  20. Power Systems for Future Missions: Appendices A-L

    NASA Technical Reports Server (NTRS)

    Gill, S. P.; Frye, P. E.; Littman, Franklin D.; Meisl, C. J.

    1994-01-01

    Selection of power system technology for space applications is typically based on mass, readiness of a particular technology to meet specific mission requirements, and life cycle costs (LCC). The LCC is typically used as a discriminator between competing technologies for a single mission application. All other future applications for a given technology are usually ignored. As a result, development cost of a technology becomes a dominant factor in the LCC comparison. Therefore, it is common for technologies such as DIPS and LMR-CBC to be potentially applicable to a wide range of missions and still lose out in the initial LCC comparison due to high development costs. This collection of appendices (A through L) contains the following power systems technology plans: CBC DIPS Technology Roadmap; PEM PFC Technology Roadmap; NAS Battery Technology Roadmap; PV/RFC Power System Technology Roadmap; PV/NAS Battery Technology Roadmap; Thermionic Reactor Power System Technology Roadmap; SP-100 Power System Technology Roadmap; Dynamic SP-100 Power System Technology Roadmap; Near-Term Solar Dynamic Power System Technology Roadmap; Advanced Solar Dynamic Power System Technology Roadmap; Advanced Stirling Cycle Dynamic Isotope Power System Technology Roadmap; and the ESPPRS (Evolutionary Space Power and Propulsion Requirements System) User's Guide.

  1. Evolution of E × B shear and coherent fluctuations prior to H-L transitions in DIII-D and control strategies for H-L transitions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eldon, David; Boivin, Rejean L.; Chrystal, Colin

    While operating a magnetic fusion device in H-mode has many advantages, care must be taken to understand and control the release of energy during the H-L back transition, as the extra energy stored within the H-mode transport barrier will have the potential to cause damage to material components of a large future tokamak such as ITER. Examining a scenario where the H-L back transition sequence begins before the E × B shearing layer decays on its own, we identify a long-lived precursor mode that is tied to the events of the H-L sequence and we develop a robust control strategymore » for ensuring gradual release of energy during the transition sequence. Back transitions in this scenario commonly begin with a rapid relaxation of the pedestal, which was previously shown to be inconsistent with ideal peeling-ballooning instability as the trigger, despite being otherwise similar to a large type-I Edge Localized Mode (ELM). Here, this so-called transient occurs when the E × B shearing rate ω E×B is significantly larger than the turbulence decorrelation rate ωT, indicating that this is not the result of runaway turbulence recovery. The transient is always synchronous with amplitude and propagation velocity modulations of the precursor mode, which has been dubbed the Modulating Pedestal Mode (MPM).The MPM is a coherent density fluctuation, which, in our scenario at least, reliably appears in the steep gradient region with f ≈ 70 kHz, k θ ≈ 0.3 cm –1, and it exists for ≳100 ms before the onset of back transitions. The transient may be reliably eliminated by reducing toroidal rotation in the co-current direction by the application of torque from counter-injecting neutral beams. The transient in these “soft” H-L transitions is then replaced by a small type-III ELM, which is also always synchronous with the MPM, and MPM shows the same behavior in both hard and soft cases.« less

  2. Evolution of E × B shear and coherent fluctuations prior to H-L transitions in DIII-D and control strategies for H-L transitions

    DOE PAGES

    Eldon, David; Boivin, Rejean L.; Chrystal, Colin; ...

    2015-11-19

    While operating a magnetic fusion device in H-mode has many advantages, care must be taken to understand and control the release of energy during the H-L back transition, as the extra energy stored within the H-mode transport barrier will have the potential to cause damage to material components of a large future tokamak such as ITER. Examining a scenario where the H-L back transition sequence begins before the E × B shearing layer decays on its own, we identify a long-lived precursor mode that is tied to the events of the H-L sequence and we develop a robust control strategymore » for ensuring gradual release of energy during the transition sequence. Back transitions in this scenario commonly begin with a rapid relaxation of the pedestal, which was previously shown to be inconsistent with ideal peeling-ballooning instability as the trigger, despite being otherwise similar to a large type-I Edge Localized Mode (ELM). Here, this so-called transient occurs when the E × B shearing rate ω E×B is significantly larger than the turbulence decorrelation rate ωT, indicating that this is not the result of runaway turbulence recovery. The transient is always synchronous with amplitude and propagation velocity modulations of the precursor mode, which has been dubbed the Modulating Pedestal Mode (MPM).The MPM is a coherent density fluctuation, which, in our scenario at least, reliably appears in the steep gradient region with f ≈ 70 kHz, k θ ≈ 0.3 cm –1, and it exists for ≳100 ms before the onset of back transitions. The transient may be reliably eliminated by reducing toroidal rotation in the co-current direction by the application of torque from counter-injecting neutral beams. The transient in these “soft” H-L transitions is then replaced by a small type-III ELM, which is also always synchronous with the MPM, and MPM shows the same behavior in both hard and soft cases.« less

  3. Self-adjusting threshold mechanism for pixel detectors

    NASA Astrophysics Data System (ADS)

    Heim, Timon; Garcia-Sciveres, Maurice

    2017-09-01

    Readout chips of hybrid pixel detectors use a low power amplifier and threshold discrimination to process charge deposited in semiconductor sensors. Due to transistor mismatch each pixel circuit needs to be calibrated individually to achieve response uniformity. Traditionally this is addressed by programmable threshold trimming in each pixel, but requires robustness against radiation effects, temperature, and time. In this paper a self-adjusting threshold mechanism is presented, which corrects the threshold for both spatial inequality and time variation and maintains a constant response. It exploits the electrical noise as relative measure for the threshold and automatically adjust the threshold of each pixel to always achieve a uniform frequency of noise hits. A digital implementation of the method in the form of an up/down counter and combinatorial logic filter is presented. The behavior of this circuit has been simulated to evaluate its performance and compare it to traditional calibration results. The simulation results show that this mechanism can perform equally well, but eliminates instability over time and is immune to single event upsets.

  4. Purification of L-( sup 3 H) Nicotine eliminates low affinity binding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Romm, E.; Marks, M.J.; Collins, A.C.

    1990-01-01

    Some studies of L-({sup 3}H) nicotine binding to rodent and human brain tissue have detected two binding sites as evidenced by nonlinear Scatchard plots. Evidence presented here indicated that the low affinity binding site is not stereospecific, is not inhibited by low concentrations of cholinergic agonists and is probably due to breakdown products of nicotine since purification of the L-({sup 3}H)nicotine eliminates the low affinity site.

  5. Computation provides chemical insight into the diverse hydride NMR chemical shifts of [Ru(NHC)4(L)H]0/+ species (NHC = N-heterocyclic carbene; L = vacant, H2, N2, CO, MeCN, O2, P4, SO2, H-, F- and Cl-) and their [Ru(R2PCH2CH2PR2)2(L)H]+ congeners.

    PubMed

    Häller, L Jonas L; Mas-Marzá, Elena; Cybulski, Mateusz K; Sanguramath, Rajashekharayya A; Macgregor, Stuart A; Mahon, Mary F; Raynaud, Christophe; Russell, Christopher A; Whittlesey, Michael K

    2017-02-28

    Relativistic density functional theory calculations, both with and without the effects of spin-orbit coupling, have been employed to model hydride NMR chemical shifts for a series of [Ru(NHC) 4 (L)H] 0/+ species (NHC = N-heterocyclic carbene; L = vacant, H 2 , N 2 , CO, MeCN, O 2 , P 4 , SO 2 , H - , F - and Cl - ), as well as selected phosphine analogues [Ru(R 2 PCH 2 CH 2 PR 2 ) 2 (L)H] + (R = i Pr, Cy; L = vacant, O 2 ). Inclusion of spin-orbit coupling provides good agreement with the experimental data. For the NHC systems large variations in hydride chemical shift are shown to arise from the paramagnetic term, with high net shielding (L = vacant, Cl - , F - ) being reinforced by the contribution from spin-orbit coupling. Natural chemical shift analysis highlights the major orbital contributions to the paramagnetic term and rationalizes trends via changes in the energies of the occupied Ru d π orbitals and the unoccupied σ* Ru-H orbital. In [Ru(NHC) 4 (η 2 -O 2 )H] + a δ-interaction with the O 2 ligand results in a low-lying LUMO of d π character. As a result this orbital can no longer contribute to the paramagnetic shielding, but instead provides additional deshielding via overlap with the remaining (occupied) d π orbital under the L z angular momentum operator. These two effects account for the unusual hydride chemical shift of +4.8 ppm observed experimentally for this species. Calculations reproduce hydride chemical shift data observed for [Ru( i Pr 2 PCH 2 CH 2 P i Pr 2 ) 2 (η 2 -O 2 )H] + (δ = -6.2 ppm) and [Ru(R 2 PCH 2 CH 2 PR 2 ) 2 H] + (ca. -32 ppm, R = i Pr, Cy). For the latter, the presence of a weak agostic interaction trans to the hydride ligand is significant, as in its absence (R = Me) calculations predict a chemical shift of -41 ppm, similar to the [Ru(NHC) 4 H] + analogues. Depending on the strength of the agostic interaction a variation of up to 18 ppm in hydride chemical shift is possible and this factor (that is not necessarily

  6. Response, thermal regulatory threshold and thermal breakdown threshold of restrained RF-exposed mice at 905 MHz

    NASA Astrophysics Data System (ADS)

    Ebert, S.; Eom, S. J.; Schuderer, J.; Apostel, U.; Tillmann, T.; Dasenbrock, C.; Kuster, N.

    2005-11-01

    The objective of this study was the determination of the thermal regulatory and the thermal breakdown thresholds for in-tube restrained B6C3F1 and NMRI mice exposed to radiofrequency electromagnetic fields at 905 MHz. Different levels of the whole-body averaged specific absorption rate (SAR = 0, 2, 5, 7.2, 10, 12.6 and 20 W kg-1) have been applied to the mice inside the 'Ferris Wheel' exposure setup at 22 ± 2 °C and 30-70% humidity. The thermal responses were assessed by measurement of the rectal temperature prior, during and after the 2 h exposure session. For B6C3F1 mice, the thermal response was examined for three different weight groups (20 g, 24 g, 29 g), both genders and for pregnant mice. Additionally, NMRI mice with a weight of 36 g were investigated for an interstrain comparison. The thermal regulatory threshold of in-tube restrained mice was found at SAR levels between 2 W kg-1 and 5 W kg-1, whereas the breakdown of regulation was determined at 10.1 ± 4.0 W kg-1(K = 2) for B6C3F1 mice and 7.7 ± 1.6 W kg-1(K = 2) for NMRI mice. Based on a simplified power balance equation, the thresholds show a clear dependence upon the metabolic rate and weight. NMRI mice were more sensitive to thermal stress and respond at lower SAR values with regulation and breakdown. The presented data suggest that the thermal breakdown for in-tube restrained mice, whole-body exposed to radiofrequency fields, may occur at SAR levels of 6 W kg-1(K = 2) at laboratory conditions.

  7. Economic Analysis Supporting the Increase of the Unspecified Minor Military Construction Threshold

    DTIC Science & Technology

    2016-06-01

    UNSPECIFIED MINOR MILITARY CONSTRUCTION THRESHOLD June 2016 By: Clifford L. Kelsey Advisors: Philip Candreva Amilcar Menichini...THE UNSPECIFIED MINOR MILITARY CONSTRUCTION THRESHOLD 5. FUNDING NUMBERS 6. AUTHOR(S) Clifford L. Kelsey 7. PERFORMING ORGANIZATION NAME(S) AND...words) This report analyzes the economical, technological, and environmental challenges U.S. Navy engineers face in constructing quality, usable

  8. Sub-microWatt threshold nanoisland lasers

    PubMed Central

    Jang, Hoon; Karnadi, Indra; Pramudita, Putu; Song, Jung-Hwan; Soo Kim, Ki; Lee, Yong-Hee

    2015-01-01

    Ultralow threshold nanolasers have been sought after as power efficient light sources in photonic integrated circuits. Here a single-cell nanobeam laser with a nanoisland quantum well is proposed and demonstrated. Continuous operation at 1.5 μm is achieved at room temperature with an ultralow lasing threshold of 210 nW in absorbed power. The size of the active medium is reduced to 0.7 × 0.25 × 0.02 μm3 by removing the absorptive quantum well region surrounding the central cavity. Relatively thick (420 nm) InP slabs are employed to improve the thermal and mechanical characteristics. The nanoisland-based structures will provide a new platform to engineer fundamental light–matter interactions by controlling the size and the location of the nanoemitters, allowing the realization of highly efficient nanophotonic devices. PMID:26391800

  9. A Thermally Powered ISFET Array for On-Body pH Measurement.

    PubMed

    Douthwaite, Matthew; Koutsos, Ermis; Yates, David C; Mitcheson, Paul D; Georgiou, Pantelis

    2017-12-01

    Recent advances in electronics and electrochemical sensors have led to an emerging class of next generation wearables, detecting analytes in biofluids such as perspiration. Most of these devices utilize ion-selective electrodes (ISEs) as a detection method; however, ion-sensitive field-effect transistors (ISFETs) offer a solution with improved integration and a low power consumption. This work presents a wearable, thermoelectrically powered system composed of an application-specific integrated circuit (ASIC), two commercial power management integrated circuits and a network of commercial thermoelectric generators (TEGs). The ASIC is fabricated in 0.35 m CMOS and contains an ISFET array designed to read pH as a current, a processing module which averages the signal to reduce noise and encodes it into a frequency, and a transmitter. The output frequency has a measured sensitivity of 6 to 8 kHz/pH for a pH range of 7-5. It is shown that the sensing array and processing module has a power consumption 6 W and, therefore, can be entirely powered by body heat using a TEG. Array averaging is shown to reduce noise at these low power levels to 104 V (input referred integrated noise), reducing the minimum detectable limit of the ASIC to 0.008 pH units. The work forms the foundation and proves the feasibility of battery-less, on-body electrochemical for perspiration analysis in sports science and healthcare applications.

  10. Lateral cavity photonic crystal surface emitting lasers with ultralow threshold and large power

    NASA Astrophysics Data System (ADS)

    Wang, Yufei; Qu, Hongwei; Zhou, Wenjun; Jiang, Bin; Zhang, Jianxin; Qi, Aiyi; Liu, Lei; Fu, Feiya; Zheng, Wanhua

    2012-03-01

    The Bragg diffraction condition of surface-emitting lasing action is analyzed and Γ2-1 mode is chosen for lasing. Two types of lateral cavity photonic crystal surface emitting lasers (LC-PCSELs) based on the PhC band edge mode lateral resonance and vertical emission to achieve electrically driven surface emitting laser without distributed Bragg reflectors in the long wavelength optical communication band are designed and fabricated. Deep etching techniques, which rely on the active layer being or not etched through, are adopted to realize the LC-PCSELs on the commercial AlGaInAs/InP multi-quantum-well (MQW) epitaxial wafer. 1553.8 nm with ultralow threshold of 667 A/cm2 and 1575 nm with large power of 1.8 mW surface emitting lasing actions are observed at room temperature, providing potential values for mass production with low cost of electrically driven PCSELs.

  11. Coupled photonic crystal micro-cavities with ultra-low threshold power for stimulated Raman scattering.

    PubMed

    Liu, Qiang; Ouyang, Zhengbiao; Albin, Sacharia

    2011-02-28

    We propose coupled cavities to realize a strong enhancement of the Raman scattering. Five sub cavities are embedded in the photonic crystals. Simulations through finite-difference time-domain (FDTD) method demonstrate that one cavity, which is used to propagate the pump beam at the optical-communication wavelength, has a Q factor as high as 
1.254×10⁸ and modal volume as small as 0.03 μm3 (0.3192(λ/n)3). These parameters result in ultra-small threshold lasing power~17.7 nW and 2.58 nW for Stokes and anti-Stokes respectively. The cavities are designed to support the required Stokes and anti-Stokes modal spacing in silicon. The proposed structure has the potential for sensor devices, especially for biological and medical diagnoses.

  12. Tramadol reduces the sweating, vasoconstriction, and shivering thresholds.

    PubMed

    De Witte, J L; Kim, J S; Sessler, D I; Bastanmehr, H; Bjorksten, A R

    1998-07-01

    The analgesic tramadol inhibits the neuronal reuptake of norepinephrine and 5-hydroxytryptamine, facilitates 5-hydroxytryptamine release, and activates mu-opioid receptors. Each of these actions is likely to influence thermoregulatory control. We therefore tested the hypothesis that tramadol inhibits thermoregulatory control. Eight volunteers were evaluated on four study days, on which they received no drugs, tramadol 125 mg, tramadol 250 mg, and tramadol 250 mg with naloxone, respectively. Skin and core temperatures were gradually increased until sweating was observed and then decreased until vasoconstriction and shivering were detected. The core temperature triggering each response defined its threshold. Tramadol decreased the sweating threshold by -1.03 +/- 0.67 degrees C microgram-1.mL (r2 = 0.90 +/- 0.12). Tramadol also decreased the vasoconstriction threshold by -3.0 +/- 4.0 degrees C microgram-1.mL (r2 = 0.94 +/- 0.98) and the shivering threshold by -4.2 +/- 4.0 degrees C microgram-1.mL(r2 = 0.98 +/- 0.98). The sweating to vasoconstriction interthreshold range nearly doubled from 0.3 +/- 0.4 degree C to 0.7 +/- 0.6 degree C during the administration of large-dose tramadol (P = 0.04). The addition of naloxone only partially reversed the thermoregulatory effects of tramadol. The thermoregulatory effects of tramadol thus most resemble those of midazolam, another drug that slightly decreases the thresholds triggering all three major autonomic thermoregulatory defenses. In this respect, both drugs reduce the "setpoint" rather than produce a generalized impairment of thermoregulatory control. Nonetheless, tramadol nearly doubled the interthreshold range at a concentration near 200 ng/mL. This indicates that tramadol slightly decreases the precision of thermoregulatory control in addition to reducing the setpoint. The authors evaluated the effects of the analgesic tramadol on the three major thermoregulatory responses: sweating, vasoconstriction, and shivering

  13. H. A. L. Fisher: Scholar and Minister

    ERIC Educational Resources Information Center

    Judge, Harry

    2006-01-01

    H. A. L. Fisher came from an influential family, studied at Oxford and in France and Germany, and became an Oxford academic with a strong interest in public affairs. In 1912 he became Vice-Chancellor of Sheffield University and four years later was recruited by the new British Prime Minister to become his Minister of Education. In that office he…

  14. Efficacy of a Pilot Internet-Based Weight Management Program (H.E.A.L.T.H.) and Longitudinal Physical Fitness Data in Army Reserve Soldiers

    PubMed Central

    Newton, Robert L; Han, Hongmei; Stewart, Tiffany M; Ryan, Donna H; Williamson, Donald A

    2011-01-01

    Background The primary aims of this article are to describe the utilization of an Internet-based weight management Web site [Healthy Eating, Activity, and Lifestyle Training Headquarters (H.E.A.L.T.H.)] over a 12–27 month period and to describe concurrent weight and fitness changes in Army Reserve soldiers. Methods The H.E.A.L.T.H. Web site was marketed to Army Reserve soldiers via a Web site promotion program for 27 months (phase I) and its continued usage was observed over a subsequent 12-month period (phase II). Web site usage was obtained from the H.E.A.L.T.H. Web site. Weight and fitness data were extracted from the Regional Level Application Software (RLAS). Results A total of 1499 Army Reserve soldiers registered on the H.E.A.L.T.H. Web site. There were 118 soldiers who returned to the H.E.A.L.T.H. Web site more than once. Registration rate reduced significantly following the removal of the Web site promotion program. During phase I, 778 Army Reserve soldiers had longitudinal weight and fitness data in RLAS. Men exceeding the screening table weight gained less weight compared with men below it (p < .007). Percentage change in body weight was inversely associated with change in fitness scores. Conclusions The Web site promotion program resulted in 52% of available Army Reserve soldiers registering onto the H.E.A.L.T.H. Web site, and 7.9% used the Web site more than once. The H.E.A.L.T.H. Web site may be a viable population-based weight and fitness management tool for soldier use. PMID:22027327

  15. Near-Threshold Ionization of Argon by Positron Impact

    NASA Astrophysics Data System (ADS)

    Babij, T. J.; Machacek, J. R.; Murtagh, D. J.; Buckman, S. J.; Sullivan, J. P.

    2018-03-01

    The direct single-ionization cross section for Ar by positron impact has been measured in the region above the first ionization threshold. These measurements are compared to semiclassical calculations which give rise to a power law variation of the cross section in the threshold region. The experimental results appear to be in disagreement with extensions to the Wannier theory applied to positron impact ionization, with a smaller exponent than that calculated by most previous works. In fact, in this work, we see no difference in threshold behavior between the positron and electron cases. Possible reasons for this discrepancy are discussed.

  16. Effect of strong fragrance on olfactory detection threshold.

    PubMed

    Fasunla, Ayotunde James; Douglas, David Dayo; Adeosun, Aderemi Adeleke; Steinbach, Silke; Nwaorgu, Onyekwere George Benjamin

    2014-09-01

    To assess the olfactory threshold of healthy volunteers at the University College Hospital, Ibadan and to investigate the effect of perfume on their olfactory detection thresholds. A quasi-experimental study on olfactory detection thresholds of healthy volunteers from September 2013 to November 2013. Tertiary health institution. A structured questionniare was administered to the participants in order to obtain information on sociodemographics, occupation, ability to perceive smell, use of perfume, effects of perfume on appetite and self-confidence, history of allergy, and previous nasal surgery. Participants subjectively rated their olfactory performance. Subsequently, they had olfactory detection threshold testing done at baseline and after exposure to perfume with varied concentrations of n-butanol in a forced triple response and staircase fashion. Healthy volunteers, 37 males and 63 females, were evaluated. Their ages ranged from 19 to 59 years with a mean of 31 years ± 8. Subjectively, 94% of the participants had excellent olfactory function. In the pre-exposure forced triple response, 88% were able to detect the odor at ≤.25 mmol/l concentration while in the post-exposure forced triple response, only 66% were able to detect the odor at ≤.25 mmol/l concentration. There is also a statistical significant difference in the olfactory detection threshold score between the pre-exposure and post-exposure period in the participants (P < .05). Use of strong fragrances affects the olfactory detection threshold. Therefore patients and clinicians should be aware of this and its effects on the outcome of test of olfaction. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.

  17. Non-invasive indices for the estimation of the anaerobic threshold of oarsmen.

    PubMed

    Erdogan, A; Cetin, C; Karatosun, H; Baydar, M L

    2010-01-01

    This study compared four common non-invasive indices with an invasive index for determining the anaerobic threshold (AT) in 22 adult male rowers using a Concept2 rowing ergometer. A criterion-standard progressive incremental test (invasive method) measured blood lactate concentrations to determine the 4 mmol/l threshold (La4-AT) and Dmax AT (Dm-AT). This was compared with three indices obtained by analysis of respiratory gases and one that was based on the heart rate (HR) deflection point (HRDP) all of which used the Conconi test (non-invasive methods). In the Conconi test, the HRDP was determined whilst continuously increasing the power output (PO) by 25 W/min and measuring respiratory gases and HR. The La4-AT and Dm-AT values differed slightly with respect to oxygen uptake, PO and HR however, AT values significantly correlated with each other and with the four non-invasive methods. In conclusion, the non-invasive indices were comparable with the invasive index and could, therefore, be used in the assessment of AT during rowing ergometer use. In this population of elite rowers, Conconi threshold (Con-AT), based on the measurement of HRDP tended to be the most adequate way of estimating AT for training regulation purposes.

  18. Doxapram Only Slightly Reduces the Shivering Threshold in Healthy Volunteers

    PubMed Central

    Komatsu, Ryu; Sengupta, Papiya; Cherynak, Grigory; Wadhwa, Anupama; Sessler, Daniel I.; Liu, Jin; Hurst, Harrell E.; Lenhardt, Rainer

    2005-01-01

    We determined the effects of doxapram on the major autonomic thermoregulatory responses in humans. Nine healthy volunteers were studied on two days: Control and Doxapram (intravenous infusion to a plasma concentration of 2.4 ±0.8 μg/mL, 2.5 ±0.9 μg/mL, and 2.6 ±1.1 μg/mL at the sweating, vasoconstriction, and shivering thresholds, respectively). Each day, skin and core temperatures were increased to provoke sweating, then reduced to elicit peripheral vasoconstriction and shivering. We determined the sweating, vasoconstriction, and shivering thresholds with compensation for changes in skin temperature. Data were analyzed with paired t tests and presented as means ± SDs; P < 0.05 was considered statistically significant. Doxapram did not change the sweating (Control: 37.5±0.4°C, Doxapram: 37.3±0.4°C, P=0.290) or the vasoconstriction threshold (36.8±0.7 vs. 36.4±0.5°C; P=0.110). However, it significantly reduced the shivering threshold from 36.2±0.5 to 35.7±0.7°C (P=0.012). No sedation or symptoms of panic were observed on either study day. The observed reduction in the shivering threshold explains the drug's efficacy for treatment of postoperative shivering; however, a reduction of only 0.5°C is unlikely to markedly facilitate induction of therapeutic hypothermia as a sole agent. PMID:16243996

  19. Lack of concordance amongst measurements of individual anaerobic threshold and maximal lactate steady state on a cycle ergometer.

    PubMed

    Arratibel-Imaz, Iñaki; Calleja-González, Julio; Emparanza, Jose Ignacio; Terrados, Nicolas; Mjaanes, Jeffrey M; Ostojic, Sergej M

    2016-01-01

    The calculation of exertion intensity, in which a change is produced in the metabolic processes which provide the energy to maintain physical work, has been defined as the anaerobic threshold (AT). The direct calculation of maximal lactate steady state (MLSS) would require exertion intensities over a long period of time and with sufficient rest periods which would prove significantly difficult for daily practice. Many protocols have been used for the indirect calculation of MLSS. The aim of this study is to determine if the results of measurements with 12 different AT calculation methods and calculation software [Keul, Simon, Stegmann, Bunc, Dickhuth (TKM and WLa), Dmax, Freiburg, Geiger-Hille, Log-Log, Lactate Minimum] can be used interchangeably, including the method of the fixed threshold of Mader/OBLA's 4 mmol/l and then to compare them with the direct measurement of MLSS. There were two parts to this research. Phase 1: results from 162 exertion tests chosen at random from the 1560 tests. Phase 2: sixteen athletes (n = 16) carried out different tests on five consecutive days. There was very high concordance among all the methods [intraclass correlation coefficient (ICC) > 0.90], except Log-Log in relation to the Stegamnn, Dmax, Dickhuth-WLa and Geiger-Hille. The Dickhuth-TKM showed a high tendency towards concordance, with Dmax (2.2 W) and Dickhuth-WLa (0.1 W). The Dickhuth-TKM method presented a high tendency to concordance with Dickhuth-WLa (0.5 W), Freiburg (7.4 W), MLSS (2.0 W), Bunc (8.9 W), Dmax (0.1 W). The calculation of MLSS power showed a high tendency to concordance, with Dickhuth-TKM (2 W), Dmax (2.1 W), Dickhuth-WLa (1.5 W). The fixed threshold of 4 mmol/l or OBLA produces slightly different and higher results than those obtained with all the methods analyzed, including MLSS, meaning an overestimation of power in the individual anaerobic threshold. The Dickhuth-TKM, Dmax and Dickhuth-WLa methods defined a high concordance on a cycle ergometer

  20. LOFT L2-3 blowdown experiment safety analyses D, E, and G; LOCA analyses H, K, K1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perryman, J.L.; Keeler, C.D.; Saukkoriipi, L.O.

    1978-12-01

    Three calculations using conservative off-nominal conditions and evaluation model options were made using RELAP4/MOD5 for blowdown-refill and RELAP4/MOD6 for reflood for Loss-of-Fluid Test Experiment L2-3 to support the experiment safety analysis effort. The three analyses are as follows: Analysis D: Loss of commercial power during Experiment L2-3; Analysis E: Hot leg quick-opening blowdown valve (QOBV) does not open during Experiment L2-3; and Analysis G: Cold leg QOBV does not open during Experiment L2-3. In addition, the results of three LOFT loss-of-coolant accident (LOCA) analyses using a power of 56.1 MW and a primary coolant system flow rate of 3.6 millionmore » 1bm/hr are presented: Analysis H: Intact loop 200% hot leg break; emergency core cooling (ECC) system B unavailable; Analysis K: Pressurizer relief valve stuck in open position; ECC system B unavailable; and Analysis K1: Same as analysis K, but using a primary coolant system flow rate of 1.92 million 1bm/hr (L2-4 pre-LOCE flow rate). For analysis D, the maximum cladding temperature reached was 1762/sup 0/F, 22 sec into reflood. In analyses E and G, the blowdowns were slower due to one of the QOBVs not functioning. The maximum cladding temperature reached in analysis E was 1700/sup 0/F, 64.7 sec into reflood; for analysis G, it was 1300/sup 0/F at the start of reflood. For analysis H, the maximum cladding temperature reached was 1825/sup 0/F, 0.01 sec into reflood. Analysis K was a very slow blowdown, and the cladding temperatures followed the saturation temperature of the system. The results of analysis K1 was nearly identical to analysis K; system depressurization was not affected by the primary coolant system flow rate.« less

  1. Plasma core power exhaust in ELMy H-Mode in JET with ITER-Like Wall

    NASA Astrophysics Data System (ADS)

    Guillemaut, C.; Metzger, C.; Appel, L.; Drewelow, P.; Horvath, L.; Matthews, G. F.; Szepesi, G.; Solano, E. R.; contributors, JET

    2018-07-01

    The mitigation of target heat load in future steady state fusion devices will require dissipation of a significant amount of power through radiation. Plasma operations relying on ELMy H-modes could be problematic since ELMs may transport substantial amounts of power to the target without significant dissipation. Therefore, estimation of the average ELM power exhaust from the plasma core is crucial to evaluate the potential limitation on the power dissipation in ELMy H-mode regime. A series of more than 50 Type-I ELMy H-mode discharges in JET with ITER-Like Wall (JET-ILW) with a wide range of conditions has been used here to compare the average ELM power to the average input power. The effect of input power, ELM frequency, plasma current, confinement and radiation on ELM power exhaust has been studied and reported in this paper. Good agreement has been found here with previous studies made in carbon machines. This work suggests that it should not be possible to dissipate more than 70%–80% of the input power in Type-I ELMy H-modes in JET-ILW which is consistent with the maximum radiative fraction found experimentally.

  2. Contribution of cysteine residues to the structure and function of herpes simplex virus gH/gL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cairns, Tina M.; Landsburg, Daniel J.; Charles Whitbeck, J.

    2005-02-20

    In HSV types 1 and 2, gH forms a noncovalent heterodimer with gL. Previous studies demonstrated that the first 323 amino acids of gH1 and the first 161 amino acids of gL1 are sufficient for gH/gL binding. For gL1, substitution of any of its four cysteine (C) residues (all located within the gH/gL binding region) destroyed gH binding and function. Although gH1 contains 8 cysteines in its ectodomain, gH 2 contains 7 (C3 of gH1 is replaced by arginine in gH2). We found that mutation of any of the four C-terminal cysteines led to a reduction or loss of gH/gLmore » function. Mutation of C5 or C6 in gH1 or gH2 rendered the proteins non-functional. However, substitution of C7 and/or C8 in gH1 has a definite negative impact on cell-cell fusion, although these mutations had less effect on complementation. Remarkably, all four gH1 N-terminal cysteines could be mutated simultaneously with little effect on fusion or complementation. As gH2 already lacks C3, we constructed a triple mutant (gH2-C1/2/4) which exhibited a similar phenotype. Since gH1 is known to bind gL2 and vice versa, we wondered whether binding of gH2 to the heterologous gL1 would enhance the fusion defect seen with the gH2-C2 mutant. The combination of mutant gH2-C2 with wild-type gL1 was nonfunctional in a cell-cell fusion assay. Interestingly, the reciprocal was not true, as gH1-C2 could utilize both gL1 and gL2. These findings suggest that there is a structural difference in the gH2 N-terminus as compared to gH1. We also present genetic evidence for at least one disulfide bond within gH2, between cysteines 2 and 4.« less

  3. Experimental and Theoretical Study of 4H-SiC JFET Threshold Voltage Body Bias Effect from 25 C to 500 C

    NASA Technical Reports Server (NTRS)

    Neudeck, Philip G.; Spry, David J.; Chen, Liangyu

    2015-01-01

    This work reports a theoretical and experimental study of 4H-SiC JFET threshold voltage as a function of substrate body bias, device position on the wafer, and temperature from 25 C (298K) to 500 C (773K). Based on these results, an alternative approach to SPICE circuit simulation of body effect for SiC JFETs is proposed.

  4. Power management system

    DOEpatents

    Algrain, Marcelo C.; Johnson, Kris W.; Akasam, Sivaprasad; Hoff, Brian D.

    2007-10-02

    A method of managing power resources for an electrical system of a vehicle may include identifying enabled power sources from among a plurality of power sources in electrical communication with the electrical system and calculating a threshold power value for the enabled power sources. A total power load placed on the electrical system by one or more power consumers may be measured. If the total power load exceeds the threshold power value, then a determination may be made as to whether one or more additional power sources is available from among the plurality of power sources. At least one of the one or more additional power sources may be enabled, if available.

  5. The hearing threshold of a harbor porpoise (Phocoena phocoena) for impulsive sounds (L).

    PubMed

    Kastelein, Ronald A; Gransier, Robin; Hoek, Lean; de Jong, Christ A F

    2012-08-01

    The distance at which harbor porpoises can hear underwater detonation sounds is unknown, but depends, among other factors, on the hearing threshold of the species for impulsive sounds. Therefore, the underwater hearing threshold of a young harbor porpoise for an impulsive sound, designed to mimic a detonation pulse, was quantified by using a psychophysical technique. The synthetic exponential pulse with a 5 ms time constant was produced and transmitted by an underwater projector in a pool. The resulting underwater sound, though modified by the response of the projection system and by the pool, exhibited the characteristic features of detonation sounds: A zero to peak sound pressure level of at least 30 dB (re 1 s(-1)) higher than the sound exposure level, and a short duration (34 ms). The animal's 50% detection threshold for this impulsive sound occurred at a received unweighted broadband sound exposure level of 60 dB re 1 μPa(2)s. It is shown that the porpoise's audiogram for short-duration tonal signals [Kastelein et al., J. Acoust. Soc. Am. 128, 3211-3222 (2010)] can be used to estimate its hearing threshold for impulsive sounds.

  6. Effects of GABA receptor antagonists on thresholds of P23H rat retinal ganglion cells to electrical stimulation of the retina

    NASA Astrophysics Data System (ADS)

    Jensen, Ralph J.; Rizzo, Joseph F., III

    2011-06-01

    An electronic retinal prosthesis may provide useful vision for patients suffering from retinitis pigmentosa (RP). In animal models of RP, the amount of current needed to activate retinal ganglion cells (RGCs) is higher than in normal, healthy retinas. In this study, we sought to reduce the stimulation thresholds of RGCs in a degenerate rat model (P23H-line 1) by blocking GABA receptor mediated inhibition in the retina. We examined the effects of TPMPA, a GABAC receptor antagonist, and SR95531, a GABAA receptor antagonist, on the electrically evoked responses of RGCs to biphasic current pulses delivered to the subretinal surface through a 400 µm diameter electrode. Both TPMPA and SR95531 reduced the stimulation thresholds of ON-center RGCs on average by 15% and 20% respectively. Co-application of the two GABA receptor antagonists had the greatest effect, on average reducing stimulation thresholds by 32%. In addition, co-application of the two GABA receptor antagonists increased the magnitude of the electrically evoked responses on average three-fold. Neither TPMPA nor SR95531, applied alone or in combination, had consistent effects on the stimulation thresholds of OFF-center RGCs. We suggest that the effects of the GABA receptor antagonists on ON-center RGCs may be attributable to blockage of GABA receptors on the axon terminals of ON bipolar cells.

  7. Change of motion and localization of cholesterol molecule during L(alpha)-H(II) transition.

    PubMed Central

    Hayakawa, E; Naganuma, M; Mukasa, K; Shimozawa, T; Araiso, T

    1998-01-01

    Formation of the inverted hexagonal (H(II)) phase from the lamellar (L(alpha)) phase of bovine brain-extracted phosphatidylcholine (BBPC) and phosphatidylethanolamine (BBPE) was investigated using 31P-NMR with or without cholesterol. When the ratio of BBPC to BBPE was 1:1, the H(II) formation was observed in the presence of 33 mol% cholesterol (i.e., BBPC:BBPE:cholesterol = 1:1:1) at 47 degrees C. The fraction of the H(II) phase in the BBPC/BBPE/cholesterol system could be controlled by the addition of dioleoylglycerol. The change of molecular motion of cholesterol affected by the H(II) formation was measured at various ratios of the L(alpha) to H(II) phase with the time-resolved fluorescence depolarization method, using dehydroergosterol as a fluorescent probe. It is observed that the motion of cholesterol became vigorous in the mixture state of the L(alpha) and the H(II) phases compared to that in the L(alpha) or the H(II) phase only. These facts show that cholesterol has the strong ability to induce the H(II) phase, probably by special molecular motion, which includes change of its location from the headgroup area to the acyl-chain area. PMID:9533700

  8. Influence of high magnetic field on access to stationary H-modes and pedestal characteristics in Alcator C-Mod

    NASA Astrophysics Data System (ADS)

    Tolman, E. A.; Hughes, J. W.; Wolfe, S. M.; Wukitch, S. J.; LaBombard, B.; Hubbard, A. E.; Marmar, E. S.; Snyder, P. B.; Schmidtmayr, M.

    2018-04-01

    Recent Alcator C-Mod experiments have explored access to and characteristics of H-modes at magnetic fields approaching 8 T, the highest field achieved to date in a diverted tokamak. The H-modes originated from L-mode densities ranging from 1.1 × 1020~m-3 to 2.8 × 1020~m-3 , allowing insight into the density dependence of the H-mode power threshold at high magnetic field. This dependence is compared to predictions from the ITPA scaling law ([1]), finding that the law is approximately accurate at 7.8 T. However, the law underpredicted the high density H-mode threshold at lower magnetic field in previous C-Mod experiments ([2]), suggesting that the overall dependence of the threshold on magnetic field is weaker than predicted by the scaling law. The threshold data at 7.8 T also indicates that the onset of a low density branch at this magnetic field on C-Mod occurs below 1.4 × 1020~m-3 , which is lower than predicted by an existing model for low density branch onset. The H-modes achieved steady-state densities ranging from 2.3 × 1020 ~m-3 to 4.4 × 1020 ~m-3 , and higher transient densities, and had values of q 95 from 3.3 to 6.0. This parameter range allowed the achievement of all three types of H-mode routinely observed at lower magnetic field on C-Mod: the stationary, ELM-suppressed Enhanced D α (EDA) regime, seen at high densities and high values of q 95; the nonstationary ELM-free regime, seen at lower densities and values of q 95; and the ELMy regime, seen at low density, moderate q 95, and specialized plasma shape. The parameter space in which these regimes occur at 7.8 T is consistent with lower magnetic field experience. Pressure pedestal height at 7.8 T is compared to EPED [3, 4] predictions, and a scaling law for EDA density pedestal height developed between 4.5 T and 6.0 T is updated to include fields from 2.7 T to 7.8 T. Overall, this analysis increases confidence in the use of low magnetic field experience to predict some elements of high magnetic

  9. The role of turbulence-flow interactions in L- to H-mode transition dynamics: recent progress

    NASA Astrophysics Data System (ADS)

    Schmitz, L.

    2017-02-01

    Recent experimental and simulation work has substantially advanced the understanding of L-mode plasma edge turbulence and plasma flows and their mutual interaction across the L-H transition. Flow acceleration and E   ×   B shear flow amplification via the turbulent Reynolds stress have been directly observed in multiple devices, using multi-tip probe arrays, Doppler backscattering, beam emission spectroscopy, and gas puff imaging diagnostics. L-H transitions characterized by limit-cycle oscillations (LCO) allow probing of the trigger dynamics and the synergy of turbulence-driven and pressure-gradient-driven flows with high spatio-temporal resolution. L-mode turbulent structures exhibit characteristic changes in topology (tilting) and temporal and radial correlation preceding the L-H transition. Long-range toroidal flow correlations increase preceding edge-transport-barrier formation. The energy transfer from the turbulence spectrum to large-scale axisymmetric flows has been quantified in L-LCO and fast L-H transitions in several devices. After formation of a transient barrier, the increasing ion pressure gradient (via the E   ×   B flow shear associated with diamagnetic flow) sustains fluctuation suppression and secures the transition to H-mode. Heuristic models of the L-H trigger dynamics have progressed from 0D predator-prey models to 1D extended models, including neoclassical ion flow-damping and pressure-gradient evolution. Initial results from 2D and 3D reduced fluid models have been obtained for high-collisionality regimes.

  10. Initial Northwest Power Act Power Sales Contracts : Final Environmental Impact Statement. Volume 2, Appendices A--L.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    United States. Bonneville Power Administration.

    1992-01-01

    This report consists of appendices A-L of the final environmental impact statement for the Bonneville Power Administration. The appendices provide information on the following: Ninth circuit Court opinion in Forelaws on Board v. Johnson; guide to Northwest Power act contracts; guide to hydro operations; glossary; affected environment supporting documentation; environmental impacts of generic resource types; information on models used; technical information on analysis; public involvement activities; bibliography; Pacific Northwest Electric Power Planning and Conservation Act; and biological assessment. (CBS)

  11. Bifurcation analysis and dimension reduction of a predator-prey model for the L-H transition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dam, Magnus; Brøns, Morten; Juul Rasmussen, Jens

    2013-10-15

    The L-H transition denotes a shift to an improved confinement state of a toroidal plasma in a fusion reactor. A model of the L-H transition is required to simulate the time dependence of tokamak discharges that include the L-H transition. A 3-ODE predator-prey type model of the L-H transition is investigated with bifurcation theory of dynamical systems. The analysis shows that the model contains three types of transitions: an oscillating transition, a sharp transition with hysteresis, and a smooth transition. The model is recognized as a slow-fast system. A reduced 2-ODE model consisting of the full model restricted to themore » flow on the critical manifold is found to contain all the same dynamics as the full model. This means that all the dynamics in the system is essentially 2-dimensional, and a minimal model of the L-H transition could be a 2-ODE model.« less

  12. 77 FR 19127 - Defense Federal Acquisition Regulation Supplement; Inflation Adjustment of Threshold for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-30

    ...-AH65 Defense Federal Acquisition Regulation Supplement; Inflation Adjustment of Threshold for..., and to adjust the threshold, as appropriate. 10 U.S.C. 2253(a)(2) is based on section 101(b) of the Fiscal Year 1986 Department of Defense Appropriations Act (Pub. L. 99-190). The threshold was previously...

  13. Growth, spectral, thermal, laser damage threshold, microhardness, dielectric, linear and nonlinear optical properties of an organic single crystal: L-phenylalanine DL-mandelic acid

    NASA Astrophysics Data System (ADS)

    Jayaprakash, P.; Peer Mohamed, M.; Krishnan, P.; Nageshwari, M.; Mani, G.; Lydia Caroline, M.

    2016-12-01

    Single crystals of L-phenylalanine dl-mandelic acid [C9H11NO2. C8H8O3], have been grown by the slow evaporation technique at room temperature using aqueous solution. The single crystal XRD study confirms monoclinic system for the grown crystal. The functional groups present in the grown crystal have been identified by FTIR and FT-Raman analyses. The optical absorption studies show that the crystal is transparent in the visible region with a lower cut-off wavelength of 257 nm and the optical band gap energy Eg is determined to be 4.62 eV. The Kurtz powder second harmonic generation was confirmed using Nd:YAG laser with fundamental wavelength of 1064 nm. Further, the thermal studies confirmed no weight loss up to 150°C for the as-grown crystal. The photoluminescence spectrum exhibited three peaks (414 nm, 519 nm, 568 nm) due to the donation of protons from carboxylic acid to amino group. Laser damage threshold value was found to be 4.98 GW/cm2. The Vickers microhardness test was carried out on the grown crystals and there by Vickers hardness number (Hv), work hardening coefficient (n), yield strength (σy), stiffness constant C11 were evaluated. The dielectric behavior of the crystal has been determined in the frequency range 50 Hz-5 MHz at various temperatures.

  14. Individual factors associated with L- and H-type Bovine Spongiform Encephalopathy in France

    PubMed Central

    2012-01-01

    Background Cattle with L-type (L-BSE) and H-type (H-BSE) atypical Bovine Spongiform encephalopathy (BSE) were identified in 2003 in Italy and France respectively before being identified in other countries worldwide. As of December 2011, around 60 atypical BSE cases have currently been reported in 13 countries, with over one third in France. While the epidemiology of classical BSE (C-BSE) has been widely described, atypical BSEs are still poorly documented, but appear to differ from C-BSE. We analysed the epidemiological characteristics of the 12 cases of L-BSE and 11 cases of H-BSE detected in France from January 2001 to late 2009 and looked for individual risk factors. As L-BSE cases did not appear to be homogeneously distributed throughout the country, two complementary methods were used: spatial analysis and regression modelling. L-BSE and H-BSE were studied separately as both the biochemical properties of their pathological prion protein and their features differ in animal models. Results The median age at detection for L-BSE and H-BSE cases was 12.4 (range 8.4-18.7) and 12.5 (8.3-18.2) years respectively, with no significant difference between the two distributions. However, this median age differed significantly from that of classical BSE (7.0 (range 3.5-15.4) years). A significant geographical cluster was detected for L-BSE. Among animals over eight years of age, we showed that the risk of being detected as a L-BSE case increased with age at death. This was not the case for H-BSE. Conclusion To the best of our knowledge this is the first study to describe the epidemiology of the two types of atypical BSE. The geographical cluster detected for L-BSE could be partly due to the age structure of the background-tested bovine population. Our regression analyses, which adjusted for the effect of age and birth cohort showed an age effect for L-BSE and the descriptive analysis showed a particular age structure in the area where the cluster was detected. No birth

  15. N° 342-L'hépatite B et la grossesse.

    PubMed

    Castillo, Eliana; Murphy, Kellie; van Schalkwyk, Julie

    2017-03-01

    Examiner l'épidémiologie, l'histoire naturelle, l'évaluation et le traitement de l'infection au virus de l'hépatite B (VHB) durant la grossesse. Cela aidera les fournisseurs de soins obstétricaux à conseiller leurs patientes quant aux risques périnataux et aux options de prise en charge offertes aux femmes enceintes atteintes de l'hépatite B. Les éléments évalués comprennent les seuils de traitement antiviral contre le VHB pour la prévention de la transmission périnatale et pour les interventions effractives durant la grossesse pour les femmes atteintes de l'hépatite B. RéSULTATS: Nous avons recherché dans MEDLINE, Embase et CINAHL des articles en anglais sur les sujets liés à l'infection par le VHB, à la grossesse et à la transmission périnatale publiés de 1966 à mars 2016. Nous n'avons tenu compte que des résultats qui proviennent de revues systématiques, d'essais contrôlés aléatoires ou d'essais cliniques contrôlés et d'études d'observation. Nous avons également étudié d'autres articles (non publiés) trouvés sur les sites Web d'organismes d'évaluation des technologies de la santé et d'autres organismes connexes, dans des collections de directives cliniques et dans des registres d'essais cliniques, et obtenus auprès d'associations nationales et internationales de médecins spécialistes. MéTHODES DE VALIDATION: La qualité des résultats a été évaluée au moyen des critères décrits dans le rapport du Groupe d'étude canadien sur les soins de santé préventifs (Tableau 1). Les recommandations pour la pratique sont classées selon la méthode décrite dans ce rapport. MISE à JOUR DE DIRECTIVES CLINIQUES: La directive clinique sera évaluée cinq ans après sa publication afin de déterminer si une mise à jour est nécessaire. Cependant, si de nouvelles données probantes importantes sont publiées avant la fin du cycle de cinq ans, le processus peut être accéléré pour mettre à jour rapidement certaines

  16. Probability of an Abnormal Screening PSA Result Based on Age, Race, and PSA Threshold

    PubMed Central

    Espaldon, Roxanne; Kirby, Katharine A.; Fung, Kathy Z.; Hoffman, Richard M.; Powell, Adam A.; Freedland, Stephen J.; Walter, Louise C.

    2014-01-01

    Objective To determine the distribution of screening PSA values in older men and how different PSA thresholds affect the proportion of white, black, and Latino men who would have an abnormal screening result across advancing age groups. Methods We used linked national VA and Medicare data to determine the value of the first screening PSA test (ng/mL) of 327,284 men age 65+ who underwent PSA screening in the VA healthcare system in 2003. We calculated the proportion of men with an abnormal PSA result based on age, race, and common PSA thresholds. Results Among men age 65+, 8.4% had a PSA >4.0ng/mL. The percentage of men with a PSA >4.0ng/mL increased with age and was highest in black men (13.8%) versus white (8.0%) or Latino men (10.0%) (P<0.001). Combining age and race, the probability of having a PSA >4.0ng/mL ranged from 5.1% of Latino men age 65–69 to 27.4% of black men age 85+. Raising the PSA threshold from >4.0ng/mL to >10.0ng/mL, reclassified the greatest percentage of black men age 85+ (18.3% absolute change) and the lowest percentage of Latino men age 65–69 (4.8% absolute change) as being under the biopsy threshold (P<0.001). Conclusions Age, race, and PSA threshold together affect the pre-test probability of an abnormal screening PSA result. Based on screening PSA distributions, stopping screening among men whose PSA < 3ng/ml means over 80% of white and Latino men age 70+ would stop further screening, and increasing the biopsy threshold to >10ng/ml has the greatest effect on reducing the number of older black men who will face biopsy decisions after screening. PMID:24439009

  17. 14 CFR Appendix H to Part 23 - Installation of An Automatic Power Reserve (APR) System

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Installation of An Automatic Power Reserve (APR) System H Appendix H to Part 23 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT... AIRPLANES Pt. 23, App. H Appendix H to Part 23—Installation of An Automatic Power Reserve (APR) System H23.1...

  18. A proteorhodopsin-based biohybrid light-powering pH sensor.

    PubMed

    Rao, Siyuan; Guo, Zhibin; Liang, Dawei; Chen, Deliang; Wei, Yen; Xiang, Yan

    2013-10-14

    The biohybrid sensor is an emerging technique for multi-functional detection that utilizes the instinctive responses or interactions of biomolecules. We develop a biohybrid pH sensor by taking advantage of the pH-dependent photoelectric characteristics of proteorhodopsin (pR). The transient absorption kinetics study indicates that the photoelectric behavior of pR is attributed to the varying lifetime of the M intermediate at different environmental pH values. This pR-based biohybrid light-powering sensor with microfluidic design can achieve real-time pH detection with quick response and high sensitivity. The results of this work would shed light on pR and its potential applications.

  19. H-mode and Edge Physics on the Pegasus ST: Progress and Future Directions

    NASA Astrophysics Data System (ADS)

    Bongard, M. W.; Bodner, G. M.; Barr, J. L.; Burke, M. G.; Fonck, R. J.; Hinson, E. T.; Kriete, D. M.; Lewicki, B. T.; Perry, J. M.; Reusch, J. A.; Schlossberg, D. J.; Thome, K. E.; Winz, G. R.

    2015-11-01

    Ohmic H-modes are routinely attained on the Pegasus ST, in part due to the low L-H power threshold PLH arising from low-BT operation at A ~ 1 . Characteristics of H-mode include: improved τe, consistent with H98 ~ 1 edge current and pressure pedestal formation; and the occurrence of ELMs. Experiments in the past year have examined magnetic topology and density dependencies of PLH in detail. PLH exceeds ITER L-H scaling values by 10-20 ×, with PLH /PITPA 08 increasing sharply as A --> 1 . No PLH-minimizing density has been found. Unlike at high- A, PLH is insensitive to limited or diverted magnetic topologies to date. The low BT and modest pedestal values at A ~ 1 afford unique edge diagnostic accessibility to investigate ELMs and their nonlinear dynamics. Jedge (R , t) measured through a Type I ELM shows a complex pedestal collapse and filament ejection. These studies are being extended to higher Ip and longer pulse length with LHI startup to conserve Ohmic V-s and improve MHD stability. A modest-cost upgrade to the facility will enable detailed validation studies of nonlinear ELM dynamics and ELM control. This initiative will upgrade the centerstack, increasing BT by × 3 , Ohmic V-s by × 4 , and pulse lengths to 100 ms at A < 1 . 3 , as well as deploy a comprehensive 3D magnetic perturbation coil system with full poloidal coverage from frame coils and helical centerstack windings. Work supported by US DOE grant DE-FG02-96ER54375.

  20. Fluctuation scaling in the visual cortex at threshold

    NASA Astrophysics Data System (ADS)

    Medina, José M.; Díaz, José A.

    2016-05-01

    Fluctuation scaling relates trial-to-trial variability to the average response by a power function in many physical processes. Here we address whether fluctuation scaling holds in sensory psychophysics and its functional role in visual processing. We report experimental evidence of fluctuation scaling in human color vision and form perception at threshold. Subjects detected thresholds in a psychophysical masking experiment that is considered a standard reference for studying suppression between neurons in the visual cortex. For all subjects, the analysis of threshold variability that results from the masking task indicates that fluctuation scaling is a global property that modulates detection thresholds with a scaling exponent that departs from 2, β =2.48 ±0.07 . We also examine a generalized version of fluctuation scaling between the sample kurtosis K and the sample skewness S of threshold distributions. We find that K and S are related and follow a unique quadratic form K =(1.19 ±0.04 ) S2+(2.68 ±0.06 ) that departs from the expected 4/3 power function regime. A random multiplicative process with weak additive noise is proposed based on a Langevin-type equation. The multiplicative process provides a unifying description of fluctuation scaling and the quadratic S -K relation and is related to on-off intermittency in sensory perception. Our findings provide an insight into how the human visual system interacts with the external environment. The theoretical methods open perspectives for investigating fluctuation scaling and intermittency effects in a wide variety of natural, economic, and cognitive phenomena.

  1. Ultralow-threshold Kerr-lens mode-locked Ti:Al(2)O(3) laser.

    PubMed

    Kowalevicz, A M; Schibli, T R; Kärtner, F X; Fujimoto, J G

    2002-11-15

    An ultralow-threshold Kerr-lens mode-locked Ti:Al(2)O(3) laser achieved by use of an extended cavity design is demonstrated. Mode-locking thresholds as low as 156 mW are achieved. Pulses with durations as short as 14 fs and bandwidths of >100 nm with output powers of ~15 mW at 50-MHz repetition rates are generated by only 200 mW of pump power. Reducing the pump power requirements to a factor of 10x less than required by most conventional Kerr-lens mode-locked lasers permits inexpensive, low-power pump lasers to be used. This will facilitate the development of low-cost, high-performance femtosecond Ti:Al(2)O(3) laser technology.

  2. Precipitation thresholds for triggering floods in Corgo hydrographic basin (Northern Portugal)

    NASA Astrophysics Data System (ADS)

    Santos, Monica; Fragoso, Marcelo

    2016-04-01

    The precipitation is a major cause of natural hazards and is therefore related to the flood events (Borga et al., 2011; Gaál et al., 2014; Wilhelmi & Morss, 2013). The severity of a precipitation event and their potential damage is dependent on the total amount of rain but also on the intensity and duration event (Gaál et al., 2014). In this work, it was established thresholds based on critical combinations: amount / duration of flood events with daily rainfall data for Corgo hydrographic basin, in northern Portugal. In Corgo basin are recorded 31 floods events between 1865 and 2011 (Santos et al., 2015; Zêzere et al., 2014). We determined the minimum, maximum and pre-warning thresholds that define the boundaries so that an event may occur. Additionally, we applied these thresholds to different flood events occurred in the past in the study basin. The results show that the ratio between the flood events and precipitation events that occur above the minimum threshold has relatively low probability of a flood happen. These results may be related to the reduced number of floods events (only those that caused damage reported by the media and produced some type of damage). The maximum threshold is not useful for floods forecasting, since the majority of true positives are below this limit. The retrospective analysis of the thresholds defined suggests that the minimum and pre warning thresholds are well adjusted. The application of rainfall thresholds contribute to minimize possible situations of pre-crisis or immediate crisis, reducing the consequences and the resources involved in emergency response of flood events. References Borga, M., Anagnostou, E. N., Blöschl, G., & Creutin, J. D. (2011). Flash flood forecasting, warning and risk management: the HYDRATE project. Environmental Science & Policy, 14(7), 834-844. doi: 10.1016/j.envsci.2011.05.017 Gaál, L., Molnar, P., & Szolgay, J. (2014). Selection of intense rainfall events based on intensity thresholds and

  3. High-order above-threshold dissociation of molecules

    NASA Astrophysics Data System (ADS)

    Lu, Peifen; Wang, Junping; Li, Hui; Lin, Kang; Gong, Xiaochun; Song, Qiying; Ji, Qinying; Zhang, Wenbin; Ma, Junyang; Li, Hanxiao; Zeng, Heping; He, Feng; Wu, Jian

    2018-03-01

    Electrons bound to atoms or molecules can simultaneously absorb multiple photons via the above-threshold ionization featured with discrete peaks in the photoelectron spectrum on account of the quantized nature of the light energy. Analogously, the above-threshold dissociation of molecules has been proposed to address the multiple-photon energy deposition in the nuclei of molecules. In this case, nuclear energy spectra consisting of photon-energy spaced peaks exceeding the binding energy of the molecular bond are predicted. Although the observation of such phenomena is difficult, this scenario is nevertheless logical and is based on the fundamental laws. Here, we report conclusive experimental observation of high-order above-threshold dissociation of H2 in strong laser fields where the tunneling-ionized electron transfers the absorbed multiphoton energy, which is above the ionization threshold to the nuclei via the field-driven inelastic rescattering. Our results provide an unambiguous evidence that the electron and nuclei of a molecule as a whole absorb multiple photons, and thus above-threshold ionization and above-threshold dissociation must appear simultaneously, which is the cornerstone of the nowadays strong-field molecular physics.

  4. High-order above-threshold dissociation of molecules.

    PubMed

    Lu, Peifen; Wang, Junping; Li, Hui; Lin, Kang; Gong, Xiaochun; Song, Qiying; Ji, Qinying; Zhang, Wenbin; Ma, Junyang; Li, Hanxiao; Zeng, Heping; He, Feng; Wu, Jian

    2018-02-27

    Electrons bound to atoms or molecules can simultaneously absorb multiple photons via the above-threshold ionization featured with discrete peaks in the photoelectron spectrum on account of the quantized nature of the light energy. Analogously, the above-threshold dissociation of molecules has been proposed to address the multiple-photon energy deposition in the nuclei of molecules. In this case, nuclear energy spectra consisting of photon-energy spaced peaks exceeding the binding energy of the molecular bond are predicted. Although the observation of such phenomena is difficult, this scenario is nevertheless logical and is based on the fundamental laws. Here, we report conclusive experimental observation of high-order above-threshold dissociation of H 2 in strong laser fields where the tunneling-ionized electron transfers the absorbed multiphoton energy, which is above the ionization threshold to the nuclei via the field-driven inelastic rescattering. Our results provide an unambiguous evidence that the electron and nuclei of a molecule as a whole absorb multiple photons, and thus above-threshold ionization and above-threshold dissociation must appear simultaneously, which is the cornerstone of the nowadays strong-field molecular physics. Copyright © 2018 the Author(s). Published by PNAS.

  5. Research on H2 speed governor for diesel engine of marine power station

    NASA Astrophysics Data System (ADS)

    Huang, Man-Lei

    2007-09-01

    The frequency stability of a marine power system is determined by the dynamic characteristic of the diesel engine speed regulation system in a marine power station. In order to reduce the effect of load disturbances and improve the dynamic precision of a diesel engine speed governor, a controller was designed for a diesel engine speed regulation system using H2 control theory. This transforms the specifications of the system into a standard H2 control problem. Firstly, the mathematical model of a diesel engine speed regulation system using an H2 speed governor is presented. To counter external disturbances and model uncertainty, the design of an H2 speed governor rests on the problem of mixed sensitivity. Computer simulation verified that the H2 speed governor improves the dynamic precision of a system and the ability to adapt to load disturbances, thus enhancing the frequency stability of marine power systems.

  6. Human cytomegalovirus glycoprotein complex gH/gL/gO uses PDGFR-α as a key for entry

    PubMed Central

    Boos, Simone; Resch, Moritz; Brizic, Ilija; Mach, Michael; Scrivano, Laura

    2017-01-01

    Herpesvirus gH/gL envelope glycoprotein complexes are key players in virus entry as ligands for host cell receptors and by promoting fusion of viral envelopes with cellular membranes. Human cytomegalovirus (HCMV) has two alternative gH/gL complexes, gH/gL/gO and gH/gL/UL128,130,131A which both shape the HCMV tropism. By studying binding of HCMV particles to fibroblasts, we could for the first time show that virion gH/gL/gO binds to platelet-derived growth factor-α (PDGFR-α) on the surface of fibroblasts and that gH/gL/gO either directly or indirectly recruits gB to this complex. PDGFR-α functions as an entry receptor for HCMV expressing gH/gL/gO, but not for HCMV mutants lacking the gH/gL/gO complex. PDGFR-α-dependent entry is not dependent on activation of PDGFR-α. We could also show that the gH/gL/gO—PDGFR-α interaction starts the predominant entry pathway for infection of fibroblasts with free virus. Cell-associated virus spread is either driven by gH/gL/gO interacting with PDGFR-α or by the gH/gL/UL128,130,131A complex. PDGFR-α-positive cells may thus be preferred first target cells for infections with free virus which might have implications for the design of future HCMV vaccines or anti-HCMV drugs. PMID:28403202

  7. Real-time detection of faecally contaminated drinking water with tryptophan-like fluorescence: defining threshold values.

    PubMed

    Sorensen, James P R; Baker, Andy; Cumberland, Susan A; Lapworth, Dan J; MacDonald, Alan M; Pedley, Steve; Taylor, Richard G; Ward, Jade S T

    2018-05-01

    We assess the use of fluorescent dissolved organic matter at excitation-emission wavelengths of 280nm and 360nm, termed tryptophan-like fluorescence (TLF), as an indicator of faecally contaminated drinking water. A significant logistic regression model was developed using TLF as a predictor of thermotolerant coliforms (TTCs) using data from groundwater- and surface water-derived drinking water sources in India, Malawi, South Africa and Zambia. A TLF threshold of 1.3ppb dissolved tryptophan was selected to classify TTC contamination. Validation of the TLF threshold indicated a false-negative error rate of 15% and a false-positive error rate of 18%. The threshold was unsuccessful at classifying contaminated sources containing <10 TTC cfu per 100mL, which we consider the current limit of detection. If only sources above this limit were classified, the false-negative error rate was very low at 4%. TLF intensity was very strongly correlated with TTC concentration (ρ s =0.80). A higher threshold of 6.9ppb dissolved tryptophan is proposed to indicate heavily contaminated sources (≥100 TTC cfu per 100mL). Current commercially available fluorimeters are easy-to-use, suitable for use online and in remote environments, require neither reagents nor consumables, and crucially provide an instantaneous reading. TLF measurements are not appreciably impaired by common intereferents, such as pH, turbidity and temperature, within typical natural ranges. The technology is a viable option for the real-time screening of faecally contaminated drinking water globally. Copyright © 2017 Natural Environment Research Council (NERC), as represented by the British Geological Survey (BGS. Published by Elsevier B.V. All rights reserved.

  8. Fructose Administration Increases Intraoperative Core Temperature by Augmenting Both Metabolic Rate and the Vasoconstriction Threshold

    PubMed Central

    Mizobe, Toshiki; Nakajima, Yasufumi; Ueno, Hiroshi; Sessler, Daniel I.

    2006-01-01

    Background We tested the hypothesis that intravenous fructose ameliorates intraoperative hypothermia both by increasing metabolic rate and the vasoconstriction threshold (triggering core temperature) Methods 40 patients scheduled for open abdominal surgery were divided into two equal groups and randomly assigned to intravenous fructose infusion (0.5 g·kg−1·h−1 for 4 h, starting 3 h before induction of anesthesia and continuing for 4 hours) or an equal volume of saline. Each treatment group was subdivided: esophageal core temperature, thermoregulatory vasoconstriction, and plasma concentrations were determined in half, and oxygen consumption was determined in the remainder. Patients were monitored for 3 h after induction of anesthesia. Results Patient characteristics, anesthetic management, and circulatory data were similar in the four groups. Mean final core temperature (3 h after induction of anesthesia) was 35.7±0.4°C (mean ± SD) in the fructose group and 35.1±0.4°C in the saline group (P=0.001). The vasoconstriction threshold was greater in the fructose (36.2±0.3°C) than in the saline group (35.6±0.3°C; P<0.001). Oxygen consumption immediately before anesthesia induction in the fructose group (214±18 ml/min) was significantly greater than in the saline group (181±8 ml/min, P<0.001). Oxygen consumption was 4.0 L greater in the fructose patients during 3 hours of anesthesia; the predicted difference in mean-body temperature based only on the difference in metabolic rates was thus only 0.4°C. Epinephrine, norepinephrine, and angiotensin II concentrations, and plasma renin activity were similar in each treatment group. Conclusions Preoperative fructose infusion helped maintain normothermia by augmenting both metabolic heat production and increasing the vasoconstriction threshold. PMID:16732081

  9. Tunable femtosecond lasers with low pump thresholds

    NASA Astrophysics Data System (ADS)

    Oppo, Karen

    The work in this thesis is concerned with the development of tunable, femtosecond laser systems, exhibiting low pump threshold powers. The main motive for this work was the development of a low threshold, self-modelocked Ti:Al2O3 laser in order to replace the conventional large-frame argon-ion pump laser with a more compact and efficient all-solid-state alternative. Results are also presented for an all-solid-state, self-modelocked Cr:LiSAF laser, however most of this work is concerned with self-modelocked Ti:Al2O3 laser systems. In chapter 2, the operation of a regeneratively-initiated, and a hard-aperture self- modelocked Ti:Al2O3 laser, pumped by an argon-ion laser, is discussed. Continuous- wave oscillation thresholds as low as 160mW have been demonstrated, along with self-modelocked threshold powers as low as 500mW. The measurement and suppression of phase noise on modelocked lasers is discussed in chapter 3. This is followed by a comparison of the phase noise characteristics of the regeneratively-initiated, and hard-aperture self-modelocked Ti:Al2O3 lasers. The use of a synchronously-operating, high resolution electron-optical streak camera in the evaluation of timing jitter is also presented. In chapter 4, the construction and self-modelocked operation of an all-solid-state Ti:Al2O3 laser is described. The all-solid-state alternative to the conventional argon-ion pump laser was a continuous-wave, intracavity-frequency doubled, diode-laser pumped Nd:YLF ring laser. At a total diode-laser pump power of 10W, this minilaser was capable of producing a single frequency output of 1W, at 523.5nm in a TEM00 beam. The remainder of this thesis looks at the operation of a self-modelocked Ti:Al2O3 laser generating ultrashort pulses at wavelengths as long as 1053nm. The motive for this work was the development of an all-solid-state, self- modelocked Ti:Al2O3 laser operating at 1053nm, for use as a master oscillator in a Nd:glass power chain.

  10. Biofuel cell based self-powered sensing platform for L-cysteine detection.

    PubMed

    Hou, Chuantao; Fan, Shuqin; Lang, Qiaolin; Liu, Aihua

    2015-03-17

    L-cysteine (L-Cys) detection is of great importance because of its crucial roles in physiological and clinical diagnoses. In this study, a glucose/O2 biofuel cell (BFC) was assembled by using flavin adenine dinucleotide-dependent glucose dehydrogenase (FAD-GDH)-based bioanode and laccase-based biocathode. Interestingly, the open circuit potential (OCP) of the BFC could be inhibited by Cu(2+) and subsequently activated by L-Cys, by which a BFC-based self-powered sensing platform for the detection of L-Cys was proposed. The FAD-GDH activity can be inhibited by Cu(2+) and, in turn, subsequent reversible activation by L-Cys because of the binding preference of L-Cys toward Cu(2+) by forming the Cu-S bond. The preferential interaction between L-Cys and Cu(2+) facilitated Cu(2+) to remove from the surface of the bioanode, and thus, the OCP of the system could be turned on. Under optimized conditions, the OCP of the BFC was systematically increased upon the addition of the L-Cys. The OCP increment (ΔOCP) was linear with the concentration of L-Cys within 20 nM to 3 μM. The proposed sensor exhibited lower detection limit of 10 nM L-Cys (S/N = 3), which is significantly lower than those values for other methods reported so far. Other amino acids and glutathione did not affect L-Cys detection. Therefore, this developed approach is sensitive, facile, cost-effective, and environmental-friendly, and could be very promising for the reliable clinically detecting of L-Cys. This work would trigger the interest of developing BFCs based self-powered sensors for practical applications.

  11. The effect of pre-test carbohydrate ingestion on the anaerobic threshold, as determined by the lactate-minimum test.

    PubMed

    Rotstein, Arie; Dotan, Raffy; Zigel, Levana; Greenberg, Tally; Benyamini, Yael; Falk, Bareket

    2007-12-01

    The purpose of this study was to investigate the effect of pre-test carbohydrate (CHO) ingestion on anaerobic-threshold assessment using the lactate-minimum test (LMT). Fifteen competitive male distance runners capable of running 10 km in 33.5-43 min were used as subjects. LMT was performed following CHO (2x300 mL, 7% solution) or comparable placebo (Pl) ingestion, in a double-blind, randomized order. The LMT consisted of two high-intensity 1 min treadmill runs (17-21 km.h(-1)), followed by an 8 min recovery period. Subsequently, subjects performed 5 min running stages, incremented by 0.6 km.h(-1) and separated by 1 min blood-sampling intervals. Tests were terminated after 3 consecutive increases in blood-lactate concentration ([La]) had been observed. Finger-tip capillary blood was sampled for [La] and blood-glucose determination 30 min before the test's onset, during the recovery phase following the 2 high-intensity runs, and following each of the subsequent 5 min stages. Heart rate (HR) and rating of perceived exertion (RPE) were recorded after each stage. The lactate-minimum speed (LMS) was determined from the individual [La]-velocity plots and was considered reflective of the anaerobic threshold. Pre-test CHO ingestion had no effect on LMS (13.19+/-1.12 km.h(-1) vs. 13.17+/-1.08 km.h(-1) in CHO and Pl, respectively), nor on [La] and glucose concentration at that speed, or on HR and RPE responses. Pre-test CHO ingestion therefore does not affect LMS or the LMT-estimated anaerobic threshold.

  12. A high-yield, enzymatic synthesis of GDP-D-[3H]arabinose and GDP-L-[3H]fucose.

    PubMed

    Mengeling, B J; Turco, S J

    1999-02-01

    For assays involving glycosyltransferases or transporters, several GDP-sugars are either commercially unavailable or expensive. We describe an enzymatic synthesis of GDP-d-[3H]arabinosep and GDP-l-[3H]fucose that yields 66-95% nucleotide-sugar from the appropriate radiolabeled sugar in less than 30 min. The coupled reaction requires Mg2+, ATP, and GTP along with the appropriate radioactive monosaccharide, sugar-1-kinase, and pyrophosphorylase. The latter two activities are present in a cytosolic fraction of Crithidia fasciculata, which is easily grown at room temperature in simple culture medium without serum or added CO2. Addition of commercial yeast inorganic pyrophosphatase shifts the equilibrium of the pyrophosphorylase reaction toward nucleotide-sugar formation. To verify that these nucleotide-sugars are biologically active, we tested their ability to serve as substrates for glycosyltransferases. GDP-l-[3H]fucose functions as the donor substrate for recombinant human fucosyltransferase V, and GDP-d-[3H]arabinosep serves as the donor substrate for the arabinosyltransferase activities present in Leishmania major microsomes. Copyright 1999 Academic Press.

  13. H I anisotropies associated with radio-polarimetric filaments . Steep power spectra associated with cold gas

    NASA Astrophysics Data System (ADS)

    Kalberla, P. M. W.; Kerp, J.; Haud, U.; Haverkorn, M.

    2017-10-01

    Context. LOFAR detected toward 3C 196 linear polarization structures which were found subsequently to be closely correlated with cold filamentary H I structures. The derived direction-dependent H I power spectra revealed marked anisotropies for narrow ranges in velocity, sharing the orientation of the magnetic field as expected for magneto-hydrodynamical (MHD) turbulence. Aims: Using the Galactic portion of the Effelsberg-Bonn H I Survey (EBHIS) we continue our study of such anisotropies in the H I distribution in direction of two WSRT fields, Horologium and Auriga; both are well known for their prominent radio-polarimetric depolarization canals. At 349 MHz the observed pattern in total intensity is insignificant but polarized intensity and polarization angle show prominent ubiquitous structures with so far unknown origin. Methods: Apodizing the H I survey data by applying a rotational symmetric 50% Tukey window, we derive average and position angle dependent power spectra. We fit power laws and characterize anisotropies in the power distribution. We used a Gaussian analysis to determine relative abundances for the cold and warm neutral medium. Results: For the analyzed radio-polarimetric targets significant anisotropies are detected in the H I power spectra; their position angles are aligned to the prominent depolarization canals, initially detected by WSRT. H I anisotropies are associated with steep power spectra. Steep power spectra, associated with cold gas, are detected also in other fields. Conclusions: Radio-polarimetric depolarization canals are associated with filamentary H I structures that belong to the cold neutral medium (CNM). Anisotropies in the CNM are in this case linked to a steepening of the power-spectrum spectral index, indicating that phase transitions in a turbulent medium occur on all scales. Filamentary H I structures, driven by thermal instabilities, and radio-polarimetric filaments are associated with each other. The magneto-ionic medium

  14. L-Theanine Protects H9C2 Cells from Hydrogen Peroxide-Induced Apoptosis by Enhancing Antioxidant Capability.

    PubMed

    Li, Chengjian; Yan, Qiongxian; Tang, Shaoxun; Xiao, Wenjun; Tan, Zhiliang

    2018-04-09

    BACKGROUND L-theanine is a non-protein amino acid in green tea, and its hepatoprotection and neuroprotection have been verified. However, whether L-theanine can prevent cardiomyocytes from apoptosis is unclear yet. This study evaluated the protective effects of L-theanine on H2O2-induced heart injury in vitro. MATERIAL AND METHODS The certified H9C2 cells were pretreated with L-theanine (0 mM, 4 mM, 8 mM, and 16 mM) for 24 h, followed by 160 µM H2O2 solution for 4 h. The cell viability and antioxidant indices were assayed. Quantitative evaluation of apoptosis was performed by flow cytometric analysis. Nuclear morphology of the cells was monitored by 4',6-diamidino-2-phenylindole staining. Expression of Caspase-3, poly ADP-ribose polymerase (PARP), c-Jun N-terminal kinase (JNK), and mitogen-activated protein kinase p38 was assayed by Western blot. RESULTS Compared to the H2O2 treatment, all doses of L-theanine treatments increased the cell viability, glutathione level, and the activities of glutathione peroxidase and superoxide dismutase (P<0.001). The contents of reactive oxygen species, nitric oxide, and oxidized glutathione were decreased by L-theanine treatments (P<0.001). Meanwhile, L-theanine treatments decreased the apoptosis ratio of H2O2-induced H9C2 cells (P<0.001). Pro-Caspase-3 expression was upregulated and cleavaged-PARP expression was inhibited by L-theanine (P<0.001). However, the phosphorylation of JNK and p38 was not affected by L-theanine treatments (P>0.05). CONCLUSIONS These data indicate that L-theanine pretreatment prevents H2O2-induced apoptosis in H9C2 cells, probably via antioxidant capacity improvement. Therefore, it might be a promising potential drug candidate for prophylaxis of ischemia/reperfusion-induced heart diseases.

  15. Fracture of Rolled Homogeneous Steel Armor (Nucleation Threshold Stress).

    DTIC Science & Technology

    1980-01-01

    AD-AO81 618 ARMY ARMAMENT RESEARCH AND DEVELOPMENT COMMAND ABERD--ETC F/B 19/4 FRACTURE OF ROLLED HOMOGENEOUS STEEL ARMOR (NUCLEATION THRESHOL--ETC(U...ARBRL-MR-02984A QQ FRACTURE OF ROLLED HOMOGENEOUS STEEL ARMOR (NUCLEATION THRESHOLD STRESS) Gerald L Moss Lynn SeamanLy~ S, ,.DTIC S ELECTED January...nucleation stress, Crack threshold stress, Fracture, Fracture stress, Spallation, Armor, Rolled homogeneous steel armor M~ AS$TRACr (Vita ssf -- ebb

  16. DOT1L and H3K79 Methylation in Transcription and Genomic Stability.

    PubMed

    Wood, Katherine; Tellier, Michael; Murphy, Shona

    2018-02-27

    The organization of eukaryotic genomes into chromatin provides challenges for the cell to accomplish basic cellular functions, such as transcription, DNA replication and repair of DNA damage. Accordingly, a range of proteins modify and/or read chromatin states to regulate access to chromosomal DNA. Yeast Dot1 and the mammalian homologue DOT1L are methyltransferases that can add up to three methyl groups to histone H3 lysine 79 (H3K79). H3K79 methylation is implicated in several processes, including transcription elongation by RNA polymerase II, the DNA damage response and cell cycle checkpoint activation. DOT1L is also an important drug target for treatment of mixed lineage leukemia (MLL)-rearranged leukemia where aberrant transcriptional activation is promoted by DOT1L mislocalisation. This review summarizes what is currently known about the role of Dot1/DOT1L and H3K79 methylation in transcription and genomic stability.

  17. Chemical activation in Rhinella arenarum oocytes: effect of dehydroleucodine (DhL) and its hydrogenated derivative (2H-DhL).

    PubMed

    Medina, M F; Bühler, M I; Sánchez-Toranzo, G

    2015-12-01

    Mature oocytes are arrested in metaphase II due to the presence of high levels of active maturation promoting factor (MPF). After fertilization, active MPF levels decline abruptly, enabling oocytes to complete meiosis II. One of the first and universal events of oocyte activation is an increase in cytosolic Ca2+ that would be responsible for MPF inactivation. Mature oocytes can also be activated by parthenogenetic activation. The aims of this work are to test the ability of dehydroleucodine (DhL) and its hydrogenated derivative 11,13-dihydro-dehydroleucodine (2H-DhL) to induce chemical activation in amphibian oocytes and to study the participation of calcium in the process. Results indicated that DhL and 2H-DhL induced oocyte activation in a dose-dependent manner. After 90 min of treatment, DhL 36 μM was able to induce 95% activation, while 2H-DhL 36 μM was less active, with only 40% activation. Our results suggest that DhL induced the inhibition of MPF activity, probably by an increase in intracellular Ca2+ concentration. Extracellular Ca2+ would not be significant, although Ca2+ release from intracellular stores is critical. In this sense, IP3Rs and RyRs were involved in the Ca2+ transient induced by lactones. In this species, RyRs appears to be the largest contributor to Ca2+ release in DhL-induced activation. Although more studies are needed on the mechanism of action through which these lactones induce oocyte activation in Rhinella arenarum, the results of this research provide interesting perspectives for the use of these lactones as chemical activators in in vitro fertilization and cloning.

  18. Experiments on H2-O2MHD power generation

    NASA Technical Reports Server (NTRS)

    Smith, J. M.

    1980-01-01

    Magnetohydrodynamic power generation experiments utilizing a cesium-seeded H2-O2 working fluid were carried out using a diverging area Hall duct having an entrance Mach number of 2. The experiments were conducted in a high-field strength cryomagnet facility at field strengths up to 5 tesla. The effects of power takeoff location, axial duct location within the magnetic field, generator loading, B-field strength, and electrode breakdown voltage were investigated. For the operating conditions of these experiments, it is found that the power output increases with the square of the B-field and can be limited by choking of the channel or interelectrode voltage breakdown which occurs at Hall fields greater than 50 volts/insulator. Peak power densities of greater than 100 MW/cu M were achieved.

  19. Immobilization thresholds of electrofishing relative to fish size

    USGS Publications Warehouse

    Dolan, C.R.; Miranda, L.E.

    2003-01-01

    Fish size and electrical waveforms have frequently been associated with variation in electrofishing effectiveness. Under controlled laboratory conditions, we measured the electrical power required by five electrical waveforms to immobilize eight fish species of diverse sizes and shapes. Fish size was indexed by total body length, surface area, volume, and weight; shape was indexed by the ratio of body length to body depth. Our objectives were to identify immobilization thresholds, elucidate the descriptors of fish size that were best associated with those immobilization thresholds, and determine whether the vulnerability of a species relative to other species remained constant across electrical treatments. The results confirmed that fish size is a key variable controlling the immobilization threshold and further suggested that the size descriptor best related to immobilization is fish volume. The peak power needed to immobilize fish decreased rapidly with increasing fish volume in small fish but decreased slowly for fish larger than 75-100 cm 3. Furthermore, when we controlled for size and shape, different waveforms did not favor particular species, possibly because of the overwhelming effect of body size. Many of the immobilization inconsistencies previously attributed to species might simply represent the effect of disparities in body size.

  20. Stereoselective L-(3H)quinuclidinyl benzilate-binding sites in nervous tissue of Aplysia californica: evidence for muscarinic receptors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murray, T.F.; Mpitsos, G.J.; Siebenaller, J.F.

    The muscarinic antagonist L-(/sup 3/H)quinuclidinyl benzilate (L-(/sup 3/H)QNB) binds with a high affinity (Kd = 0.77 nM) to a single population of specific sites (Bmax = 47 fmol/mg of protein) in nervous tissue of the gastropod mollusc, Aplysia. The specific L-(/sup 3/H)QNB binding is displaced stereoselectively by the enantiomers of benzetimide, dexetimide, and levetimide. The pharmacologically active enantiomer, dexetimide, is more potent than levetimide as an inhibitor of L-(/sup 3/H)QNB binding. Moreover, the muscarinic cholinergic ligands, scopolamine, atropine, oxotremorine, and pilocarpine are effective inhibitors of the specific L-(/sup 3/H)QNB binding, whereas nicotinic receptor antagonists, decamethonium and d-tubocurarine, are considerably lessmore » effective. These pharmacological characteristics of the L-(/sup 3/H)QNB-binding site provide evidence for classical muscarinic receptors in Aplysia nervous tissue. The physiological relevance of the dexetimide-displaceable L-(/sup 3/H)QNB-binding site was supported by the demonstration of the sensitivity of the specific binding to thermal denaturation. Specific binding of L-(/sup 3/H)QNB was also detected in nervous tissue of another marine gastropod, Pleurobranchaea californica. The characteristics of the Aplysia L-(/sup 3/H)QNB-binding site are in accordance with studies of numerous vertebrate and invertebrate tissues indicating that the muscarinic cholinergic receptor site has been highly conserved through evolution.« less

  1. Power generation by a pH-regulated conical nanopore through reverse electrodialysis

    NASA Astrophysics Data System (ADS)

    Hsu, Jyh-Ping; Lin, Sheng-Chang; Lin, Chih-Yuan; Tseng, Shiojenn

    2017-10-01

    To assess the possibility of energy harvesting through reverse electrodialysis (RED), we consider the electrokinetic behavior of the ion transport in a pH-regulated conical nanopore connecting two large reservoirs having different bulk salt concentrations, taking account of the effect of osmotic flow. In particular, we examine the influence of the ion diffusion direction, the solution pH, and the bulk concentration ratio on that behavior in detail, and discuss the underlying mechanisms. We show that the geometrically asymmetric nature of the nanopore yields profound and interesting phenomena arising mainly from the distribution of ions in its interior. Assuming a single polymeric nanopore, a power density of 18.2 W/m2 can be generated. We show that the present system has the potential of serving as an ion-selective and a salinity gradient power generation device. The maximum power efficiency which is based on assuming a linear ionic distribution in nanopore can yield appreciable deviation, especially if pH deviates significantly from 7, where the presence of H+ and OH- needs be considered.

  2. Target weight achievement and ultrafiltration rate thresholds: potential patient implications.

    PubMed

    Flythe, Jennifer E; Assimon, Magdalene M; Overman, Robert A

    2017-06-02

    Higher ultrafiltration (UF) rates and extracellular hypo- and hypervolemia are associated with adverse outcomes among maintenance hemodialysis patients. The Centers for Medicare and Medicaid Services recently considered UF rate and target weight achievement measures for ESRD Quality Incentive Program inclusion. The dual measures were intended to promote balance between too aggressive and too conservative fluid removal. The National Quality Forum endorsed the UF rate measure but not the target weight measure. We examined the proposed target weight measure and quantified weight gains if UF rate thresholds were applied without treatment time (TT) extension or interdialytic weight gain (IDWG) reduction. Data were taken from the 2012 database of a large dialysis organization. Analyses considered 152,196 United States hemodialysis patients. We described monthly patient and dialysis facility target weight achievement patterns and examined differences in patient characteristics across target weight achievement status and differences in facilities across target weight measure scores. We computed the cumulative, theoretical 1-month fluid-related weight gain that would occur if UF rates were capped at 13 mL/h/kg without concurrent TT extension or IDWG reduction. Target weight achievement patterns were stable over the year. Patients who did not achieve target weight (post-dialysis weight ≥ 1 kg above or below target weight) tended to be younger, black and dialyze via catheter, and had shorter dialysis vintage, greater body weight, higher UF rate and more missed treatments compared with patients who achieved target weight. Facilities had, on average, 27.1 ± 9.7% of patients with average post-dialysis weight ≥ 1 kg above or below the prescribed target weight. In adjusted analyses, facilities located in the midwest and south and facilities with higher proportions of black and Hispanic patients and higher proportions of patients with shorter TTs were more likely to

  3. Lower-Order Compensation Chain Threshold-Reduction Technique for Multi-Stage Voltage Multipliers.

    PubMed

    Dell' Anna, Francesco; Dong, Tao; Li, Ping; Wen, Yumei; Azadmehr, Mehdi; Casu, Mario; Berg, Yngvar

    2018-04-17

    This paper presents a novel threshold-compensation technique for multi-stage voltage multipliers employed in low power applications such as passive and autonomous wireless sensing nodes (WSNs) powered by energy harvesters. The proposed threshold-reduction technique enables a topological design methodology which, through an optimum control of the trade-off among transistor conductivity and leakage losses, is aimed at maximizing the voltage conversion efficiency (VCE) for a given ac input signal and physical chip area occupation. The conducted simulations positively assert the validity of the proposed design methodology, emphasizing the exploitable design space yielded by the transistor connection scheme in the voltage multiplier chain. An experimental validation and comparison of threshold-compensation techniques was performed, adopting 2N5247 N-channel junction field effect transistors (JFETs) for the realization of the voltage multiplier prototypes. The attained measurements clearly support the effectiveness of the proposed threshold-reduction approach, which can significantly reduce the chip area occupation for a given target output performance and ac input signal.

  4. Clinical Practice Guidelines From the AABB: Red Blood Cell Transfusion Thresholds and Storage.

    PubMed

    Carson, Jeffrey L; Guyatt, Gordon; Heddle, Nancy M; Grossman, Brenda J; Cohn, Claudia S; Fung, Mark K; Gernsheimer, Terry; Holcomb, John B; Kaplan, Lewis J; Katz, Louis M; Peterson, Nikki; Ramsey, Glenn; Rao, Sunil V; Roback, John D; Shander, Aryeh; Tobian, Aaron A R

    2016-11-15

    More than 100 million units of blood are collected worldwide each year, yet the indication for red blood cell (RBC) transfusion and the optimal length of RBC storage prior to transfusion are uncertain. To provide recommendations for the target hemoglobin level for RBC transfusion among hospitalized adult patients who are hemodynamically stable and the length of time RBCs should be stored prior to transfusion. Reference librarians conducted a literature search for randomized clinical trials (RCTs) evaluating hemoglobin thresholds for RBC transfusion (1950-May 2016) and RBC storage duration (1948-May 2016) without language restrictions. The results were summarized using the Grading of Recommendations Assessment, Development and Evaluation method. For RBC transfusion thresholds, 31 RCTs included 12 587 participants and compared restrictive thresholds (transfusion not indicated until the hemoglobin level is 7-8 g/dL) with liberal thresholds (transfusion not indicated until the hemoglobin level is 9-10 g/dL). The summary estimates across trials demonstrated that restrictive RBC transfusion thresholds were not associated with higher rates of adverse clinical outcomes, including 30-day mortality, myocardial infarction, cerebrovascular accident, rebleeding, pneumonia, or thromboembolism. For RBC storage duration, 13 RCTs included 5515 participants randomly allocated to receive fresher blood or standard-issue blood. These RCTs demonstrated that fresher blood did not improve clinical outcomes. It is good practice to consider the hemoglobin level, the overall clinical context, patient preferences, and alternative therapies when making transfusion decisions regarding an individual patient. Recommendation 1: a restrictive RBC transfusion threshold in which the transfusion is not indicated until the hemoglobin level is 7 g/dL is recommended for hospitalized adult patients who are hemodynamically stable, including critically ill patients, rather than when the hemoglobin level

  5. The threshold laws for electron-atom and positron-atom impact ionization

    NASA Technical Reports Server (NTRS)

    Temkin, A.

    1983-01-01

    The Coulomb-dipole theory is employed to derive a threshold law for the lowest energy needed for the separation of three particles from one another. The study focuses on an electron impinging on a neutral atom, and the dipole is formed between an inner electron and the nucleus. The analytical dependence of the transition matrix element on energy is reduced to lowest order to obtain the threshold law, with the inner electron providing a shield for the nucleus. Experimental results using the LAMPF accelerator to produce a high energy beam of H- ions, which are then exposed to an optical laser beam to detach the negative H- ion, are discussed. The threshold level is found to be confined to the region defined by the upper bound of the inverse square of the Coulomb-dipole region. Difficulties in exact experimental confirmation of the threshold are considered.

  6. A study of the threshold method utilizing raingage data

    NASA Technical Reports Server (NTRS)

    Short, David A.; Wolff, David B.; Rosenfeld, Daniel; Atlas, David

    1993-01-01

    The threshold method for estimation of area-average rain rate relies on determination of the fractional area where rain rate exceeds a preset level of intensity. Previous studies have shown that the optimal threshold level depends on the climatological rain-rate distribution (RRD). It has also been noted, however, that the climatological RRD may be composed of an aggregate of distributions, one for each of several distinctly different synoptic conditions, each having its own optimal threshold. In this study, the impact of RRD variations on the threshold method is shown in an analysis of 1-min rainrate data from a network of tipping-bucket gauges in Darwin, Australia. Data are analyzed for two distinct regimes: the premonsoon environment, having isolated intense thunderstorms, and the active monsoon rains, having organized convective cell clusters that generate large areas of stratiform rain. It is found that a threshold of 10 mm/h results in the same threshold coefficient for both regimes, suggesting an alternative definition of optimal threshold as that which is least sensitive to distribution variations. The observed behavior of the threshold coefficient is well simulated by assumption of lognormal distributions with different scale parameters and same shape parameters.

  7. Electron mass stopping power in H2

    NASA Astrophysics Data System (ADS)

    Fursa, Dmitry V.; Zammit, Mark C.; Threlfall, Robert L.; Savage, Jeremy S.; Bray, Igor

    2017-08-01

    Calculations of electron mass stopping power (SP) of electrons in H2 have been performed using the convergent close-coupling method for incident electron energies up to 2000 eV. Convergence of the calculated SP has been established by increasing the size of the close-coupling expansion from 9 to 491 states. Good agreement was found with the SP measurements of Munoz et al. [Chem. Phys. Lett. 433, 253 (2007), 10.1016/j.cplett.2006.10.114].

  8. Single speckle SRS threshold as determined by electron trapping, collisions and speckle duration

    NASA Astrophysics Data System (ADS)

    Rose, Harvey; Daughton, William; Yin, Lin; Langdon, Bruce

    2008-11-01

    Speckle SRS intensity threshold has been shown to increase with spatial dimension, D, because both diffraction and trapped electron escape rate increase with D, though the net effect is to substantially decrease the threshold compared to 1D linear gain calculations. On the other hand, the apparent threshold appears to decrease with integration time in PIC simulations. We present an optimum nonlinearly resonant calculation of the SRS threshold, taking into account large fluctuations of the SRS seed reflectivity, R0. Such fluctuations, absent in 1D, are caused by a gap in the linear reflectivity gain spectrum which leads to an exponential probability distribution for R0. While the SRS threshold intensity is of course finite, these fluctuations lead to a decrease of apparent threshold with increasing speckle lifetime. L. Yin et al., Physics of Plasmas 15, 013109 (2008). D. S. Montgomery et al., 9, 2311(2002). Bruce Langdon et al., 38^th Anomalous Absorption Conference (2008). Harvey A. Rose, Physics of Plasmas 10, 1468 (2003). Harvey A. Rose and L. Yin, Physics of Plasmas 15, 042311 (2008)., Harvey A. Rose and David A. Russell, Phys. Plasma 8, 4784 (2001).

  9. Detections of Long Carbon Chains CH_{3}CCCCH, C_{6}H, LINEAR-C_{6}H_{2} and C_{7}H in the Low-Mass Star Forming Region L1527

    NASA Astrophysics Data System (ADS)

    Araki, Mitsunori; Takano, Shuro; Sakai, Nami; Yamamoto, Satoshi; Oyama, Takahiro; Kuze, Nobuhiko; Tsukiyama, Koichi

    2017-06-01

    Carbon chains in the warm carbon chain chemistry (WCCC) region has been searched in the 42-44 GHz region by using Green Bank 100 m telescope. Long carbon chains C_{7}H, C_{6}H, CH_{3}CCCCH, and linear-C_{6}H_{2} and cyclic species C_{3}H and C_{3}H_{2}O have been detected in the low-mass star forming region L1527, performing the WCCC. C_{7}H was detected for the first time in molecular clouds. The column density of C_{7}H is derived to be 6.2 × 10^{10} cm^{-2} by using the detected J = 24.5-23.5 and 25.5-24.5 rotational lines. The ^{2}Π_{1/2} electronic state of C_{6}H, locating 21.6 K above the ^{2}Π_{3/2} electronic ground state, and the K_a = 0 line of the para species of linear-C_{6}H_{2} were also detected firstly in molecular clouds. The column densities of the ^{2}Π_{1/2} and ^{2}Π_{3/2} states of C_{6}H in L1527 were derived to be 1.6 × 10^{11} and 1.1 × 10^{12} cm^{-2}, respectively. The total column density of linear-C_{6}H_{2} is obtained to be 1.86 × 10^{11} cm^{-2}. While the abundance ratios of carbon chains in between L1527 and the starless dark cloud Taurus Molecular Cloud-1 Cyanopolyyne Peak (TMC-1 CP) have a trend of decrease by extension of carbon-chain length, column densities of CH_{3}CCCCH and C_{6}H are on the trend. However, the column densities of linear-C_{6}H_{2}, and C_{7}H are as abundant as those of TMC-1 CP in spite of long carbon chain, i.e., they are not on the trend. The abundances of linear-C_{6}H_{2} and C_{7}H show that L1527 is rich for long carbon chains as well as TMC-1 CP.

  10. Structural and preliminary molecular dynamics studies of the Rhodobacter sphaeroides reaction center and its mutant form L(M196)H + H(M202)L

    NASA Astrophysics Data System (ADS)

    Klyashtorny, V. G.; Fufina, T. Yu.; Vasilieva, L. G.; Shuvalov, V. A.; Gabdulkhakov, A. G.

    2014-07-01

    Pigment-protein interactions are responsible for the high efficiency of the light-energy transfer and conversion in photosynthesis. The reaction center (RC) from the purple bacterium Rhodobacter sphaeroides is the most convenient model for studying the mechanisms of primary processes of photosynthesis. Site-directed mutagenesis can be used to study the effect of the protein environment of electron-transfer cofactors on the optical properties, stability, pigment composition, and functional activity of RC. The preliminary analysis of RC was performed by computer simulation of the amino acid substitutions L(M196)H + H(M202)L at the pigment-protein interface and by estimating the stability of the threedimensional structure of the mutant RC by the molecular dynamics method. The doubly mutated reaction center was overexpressed, purified, and crystallized. The three-dimensional structure of this mutant was determined by X-ray crystallography and compared with the molecular dynamics model.

  11. Liquid lithium loop system to solve challenging technology issues for fusion power plant

    NASA Astrophysics Data System (ADS)

    Ono, M.; Majeski, R.; Jaworski, M. A.; Hirooka, Y.; Kaita, R.; Gray, T. K.; Maingi, R.; Skinner, C. H.; Christenson, M.; Ruzic, D. N.

    2017-11-01

    Steady-state fusion power plant designs present major divertor technology challenges, including high divertor heat flux both in steady-state and during transients. In addition to these concerns, there are the unresolved technology issues of long term dust accumulation and associated tritium inventory and safety issues. It has been suggested that radiation-based liquid lithium (LL) divertor concepts with a modest lithium-loop could provide a possible solution for these outstanding fusion reactor technology issues, while potentially improving reactor plasma performance. The application of lithium (Li) in NSTX resulted in improved H-mode confinement, H-mode power threshold reduction, and reduction in the divertor peak heat flux while maintaining essentially Li-free core plasma operation even during H-modes. These promising results in NSTX and related modeling calculations motivated the radiative liquid lithium divertor concept and its variant, the active liquid lithium divertor concept, taking advantage of the enhanced or non-coronal Li radiation in relatively poorly confined divertor plasmas. To maintain the LL purity in a 1 GW-electric class fusion power plant, a closed LL loop system with a modest circulating capacity of ~1 l s-1 is envisioned. We examined two key technology issues: (1) dust or solid particle removal and (2) real time recovery of tritium from LL while keeping the tritium inventory level to an acceptable level. By running the LL-loop continuously, it can carry the dust particles and impurities generated in the vacuum vessel to the outside where the dust/impurities can be removed by relatively simple dust filter, cold trap and/or centrifugal separation systems. With ~1 l s-1 LL flow, even a small 0.1% dust content by weight (or 0.5 g s-1) suggests that the LL-loop could carry away nearly 16 tons of dust per year. In a 1 GW-electric (or ~3 GW fusion power) fusion power plant, about 0.5 g s-1 of tritium is needed to maintain the fusion fuel cycle

  12. Observation of the L-H confinement bifurcation triggered by a turbulence-driven shear flow in a tokamak plasma.

    PubMed

    Yan, Z; McKee, G R; Fonck, R; Gohil, P; Groebner, R J; Osborne, T H

    2014-03-28

    Comprehensive 2D turbulence and eddy flow velocity measurements on DIII-D demonstrate a rapidly increasing turbulence-driven shear flow that develops ∼100  μs prior to the low-confinement (L mode) to high-confinement (H mode) transition and appears to trigger it. These changes are localized to a narrow layer 1-2 cm inside the magnetic boundary. Increasing heating power increases the Reynolds stress, the energy transfer from turbulence to the poloidal flow, and the edge flow shearing rate that then exceeds the decorrelation rate, suppressing turbulence and triggering the transition.

  13. Restrictive transfusion threshold is safe in high-risk patients undergoing brain tumor surgery.

    PubMed

    Alkhalid, Yasmine; Lagman, Carlito; Sheppard, John P; Nguyen, Thien; Prashant, Giyarpuram N; Ziman, Alyssa F; Yang, Isaac

    2017-12-01

    To assess the safety of a restrictive threshold for the transfusion of red blood cells (RBCs) compared to a liberal threshold in high-risk patients undergoing brain tumor surgery. We reviewed patients who were 50 years of age or older with a preoperative American Society of Anesthesiologists physical status class II to V who underwent open craniotomy for tumor resection and were transfused packed RBCs during or after surgery. We retrospectively assigned patients to a restrictive-threshold (a pretransfusion hemoglobin level <8g/dL) or a liberal-threshold group (a pretransfusion hemoglobin level of 8-10/dL). The primary outcome was in-hospital mortality rate. Secondary outcomes were in-hospital complication rates, length of stay, and discharge disposition. Twenty-five patients were included in the study, of which 17 were assigned to a restrictive-threshold group and 8 patients to a liberal-threshold group. The in-hospital mortality rates were 12% for the restrictive-threshold group (odds ratio [OR] 0.93, 95% confidence interval [CI] 0.07-12.11) and 13% for the liberal-threshold group. The in-hospital complication rates were 52.9% for the restrictive-threshold group (OR 1.13, 95% CI 0.21-6.05) and 50% for the liberal-threshold group. The average number of days in the intensive care unit and hospital were 8.6 and 22.4 days in the restrictive-threshold group and 6 and 15 days in the liberal-threshold group, respectively (P=0.69 and P=0.20). The rates of non-routine discharge were 71% in the restrictive-threshold group (OR 2.40, 95% CI 0.42-13.60) and 50% in the liberal-threshold group. A restrictive transfusion threshold did not significantly influence in-hospital mortality or complication rates, length of stay, or discharge disposition in patients at high operative risk. Copyright © 2017. Published by Elsevier B.V.

  14. Rainfall thresholds for possible landslide occurrence in Italy

    NASA Astrophysics Data System (ADS)

    Peruccacci, Silvia; Brunetti, Maria Teresa; Gariano, Stefano Luigi; Melillo, Massimo; Rossi, Mauro; Guzzetti, Fausto

    2017-08-01

    The large physiographic variability and the abundance of landslide and rainfall data make Italy an ideal site to investigate variations in the rainfall conditions that can result in rainfall-induced landslides. We used landslide information obtained from multiple sources and rainfall data captured by 2228 rain gauges to build a catalogue of 2309 rainfall events with - mostly shallow - landslides in Italy between January 1996 and February 2014. For each rainfall event with landslides, we reconstructed the rainfall history that presumably caused the slope failure, and we determined the corresponding rainfall duration D (in hours) and cumulated event rainfall E (in mm). Adopting a power law threshold model, we determined cumulated event rainfall-rainfall duration (ED) thresholds, at 5% exceedance probability, and their uncertainty. We defined a new national threshold for Italy, and 26 regional thresholds for environmental subdivisions based on topography, lithology, land-use, land cover, climate, and meteorology, and we used the thresholds to study the variations of the rainfall conditions that can result in landslides in different environments, in Italy. We found that the national and the environmental thresholds cover a small part of the possible DE domain. The finding supports the use of empirical rainfall thresholds for landslide forecasting in Italy, but poses an empirical limitation to the possibility of defining thresholds for small geographical areas. We observed differences between some of the thresholds. With increasing mean annual precipitation (MAP), the thresholds become higher and steeper, indicating that more rainfall is needed to trigger landslides where the MAP is high than where it is low. This suggests that the landscape adjusts to the regional meteorological conditions. We also observed that the thresholds are higher for stronger rocks, and that forested areas require more rainfall than agricultural areas to initiate landslides. Finally, we

  15. Expression levels of glycoprotein O (gO) vary between strains of human cytomegalovirus, influencing the assembly of gH/gL complexes and virion infectivity.

    PubMed

    Zhang, Le; Zhou, Momei; Stanton, Richard; Kamil, Jeremy; Ryckman, Brent J

    2018-05-09

    Tropism of human cytomegalovirus (HCMV) is influenced by the envelope glycoprotein complexes gH/gL/gO and gH/gL/UL128-131. During virion assembly, gO and the UL128-131 proteins compete for binding to gH/gL in the ER. This assembly process clearly differs among strains since Merlin (ME) virions contain abundant gH/gL/UL128-131 and little gH/gL/gO, whereas TR contains much higher levels of total gH/gL, mostly in the form of gH/gL/gO, but much less gH/gL/UL128-131 than ME. Remaining questions include 1) what are the mechanisms behind these assembly differences, and 2) do differences reflect in vitro culture adaptations or natural genetic variations? Since the UL74(gO) ORF differs by 25% of amino acids between TR and ME, we analyzed recombinant viruses in which the UL74(gO) ORF was swapped. TR virions were >40-fold more infectious than ME. Transcriptional repression of UL128-131 enhanced infectivity of ME to the level of TR, despite still far lower levels of gH/gL/gO. Swapping the UL74(gO) ORF had no effect on either TR or ME. A quantitative immunoprecipitation approach revealed that gH/gL expression was within 4-fold between TR and ME, but gO expression was 20-fold less by ME, and suggested differences in mRNA transcription, translation or rapid ER-associated degradation of gO. Trans-complementation of gO expression during ME replication gave 6-fold enhancement of infectivity beyond the 40-fold effect of UL128-131 repression alone. Overall, strain variations in assembly of gH/gL complexes result from differences in expression of gO and UL128-131, and selective advantages for reduced UL128-131 expression during fibroblast propagation are much stronger than for higher gO expression. IMPORTANCE Specific genetic differences between independently isolated HCMV strains may result from purifying selection on de novo mutations arising during propagation in culture, or random sampling among the diversity of genotypes present in clinical specimens. Results presented indicate

  16. Polarization properties of below-threshold harmonics from aligned molecules H2+ in linearly polarized laser fields.

    PubMed

    Dong, Fulong; Tian, Yiqun; Yu, Shujuan; Wang, Shang; Yang, Shiping; Chen, Yanjun

    2015-07-13

    We investigate the polarization properties of below-threshold harmonics from aligned molecules in linearly polarized laser fields numerically and analytically. We focus on lower-order harmonics (LOHs). Our simulations show that the ellipticity of below-threshold LOHs depends strongly on the orientation angle and differs significantly for different harmonic orders. Our analysis reveals that this LOH ellipticity is closely associated with resonance effects and the axis symmetry of the molecule. These results shed light on the complex generation mechanism of below-threshold harmonics from aligned molecules.

  17. A soluble form of Epstein-Barr virus gH/gL inhibits EBV-induced membrane fusion and does not function in fusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rowe, Cynthia L.; Connolly, Sarah A.; Chen, Jia

    We investigated whether soluble EBV gH/gL (sgH/gL) functions in fusion and made a series of truncations of gH/gL domains based on the gH/gL crystal structure. We found sgH/gL failed to mediate cell-cell fusion both when co-expressed with the other entry glycoproteins and when added exogenously to fusion assays. Interestingly, sgH/gL inhibited cell-cell fusion in a dose dependent manner when co-expressed. sgH/gL from HSV was unable to inhibit EBV fusion, suggesting the inhibition was specific to EBV gH/gL. sgH/gL stably binds gp42, but not gB nor gH/gL. The domain mutants, DI/gL, DI-II/gL and DI-II-III/gL were unable to bind gp42. Instead, DI-II/gL,more » DI-II-III/gL and sgH/gL but not DI/gL decreased the expression of gp42, resulting in decreased overall fusion. Overall, our results suggest that domain IV may be required for proper folding and the transmembrane domain and cytoplasmic tail of EBV gH/gL are required for the most efficient fusion.« less

  18. A photoelectron spectroscopic investigation of vinyl fluoride (C2H3F): the HeI, threshold and CIS photoelectron spectroscopy

    NASA Astrophysics Data System (ADS)

    Locht, R.; Leyh, B.; Dehareng, D.; Hottmann, K.; Baumgärtel, H.

    2010-01-01

    The threshold photoelectron spectrum (TPES) and the constant ion state (CIS) spectra of the individual ionic states of C2H3F have been recorded using synchrotron radiation. For comparison a well-resolved HeI photoelectron spectrum (HeI-PES) has also been measured and analysed in detail. The TPES has been measured between 9.5 eV and 35 eV photon energy. Numerous vibrational structures, reported for the first time, observed in the ground state and the six excited states of the cation are analysed. Quantum chemical calculations have been performed and provide strong support to the assignments. State-selected CIS spectra highlighted the major importance of autoionization for the production of almost all ionized states of C2H3F observed in this work.

  19. Molecular Cloning and Sequencing of Channel Catfish, Ictalurus punctatus, Cathepsin H and L cDNA

    USDA-ARS?s Scientific Manuscript database

    Cathepsin H and L, a lysosomal cysteine endopeptidase of the papain family, are ubiquitously expressed and involve in antigen processing. In this communication, the channel catfish cathepsin H and L transcripts were sequenced and analyzed. Total RNA from tissues was extracted and cDNA libraries we...

  20. Excitability in chemical and biochemical pH-autocatalytic systems.

    PubMed

    Zagora, J; Voslar, M; Schreiberová, L; Schreiber, I

    2001-01-01

    Using two different kinds of pH systems--the papain catalyzed hydrolysis of N-benzoyl-L-arginine ethyl ester in a membrane reactor and the bromate-sulfite-ferrocyanide (BSF) reaction in the CSTR--we study the relation among excitability, oscillations and bistability, and the ability of the system to respond to external periodic perturbations. Excitable properties of dynamical systems are examined in terms of a threshold set which is used to characterise dynamics in the reactor subject to external periodic stimuli. A precise definition and a method of calculating the threshold set are formulated. Two kinds of excitability distinguished by either direct or indirect initiation of the activatory process are found in both pH systems. Periodic pulsed perturbations of the BSF system display a nontrivial dependence of an excitation number on the forcing period. We examined this system also in oscillatory mode by looking at the phase shifts caused by single-pulse perturbations and constructing the phase transition curves (PTCs).

  1. HIV-1 Drug Resistance and Second-Line Treatment in Children Randomized to Switch at Low Versus Higher RNA Thresholds.

    PubMed

    Harrison, Linda; Melvin, Ann; Fiscus, Susan; Saidi, Yacine; Nastouli, Eleni; Harper, Lynda; Compagnucci, Alexandra; Babiker, Abdel; McKinney, Ross; Gibb, Diana; Tudor-Williams, Gareth

    2015-09-01

    The PENPACT-1 trial compared virologic thresholds to determine when to switch to second-line antiretroviral therapy (ART). Using PENPACT-1 data, we aimed to describe HIV-1 drug resistance accumulation on first-line ART by virologic threshold. PENPACT-1 had a 2 × 2 factorial design, randomizing HIV-infected children to start protease inhibitor (PI) versus nonnucleoside reverse transcriptase inhibitor (NNRTI)-based ART, and switch at a 1000 copies/mL versus 30,000 copies/mL threshold. Switch criteria were not achieving the threshold by week 24, confirmed rebound above the threshold thereafter, or Center for Disease Control and Prevention stage C event. Resistance tests were performed on samples ≥1000 copies/mL before switch, resuppression, and at 4-years/trial end. Sixty-seven children started PI-based ART and were randomized to switch at 1000 copies/mL (PI-1000), 64 PIs and 30,000 copies/mL (PI-30,000), 67 NNRTIs and 1000 copies/mL (NNRTI-1000), and 65 NNRTI and 30,000 copies/mL (NNRTI-30,000). Ninety-four (36%) children reached the 1000 copies/mL switch criteria during 5-year follow-up. In 30,000 copies/mL threshold arms, median time from 1000 to 30,000 copies/mL switch criteria was 58 (PI) versus 80 (NNRTI) weeks (P = 0.81). In NNRTI-30,000, more nucleoside reverse transcriptase inhibitor (NRTI) resistance mutations accumulated than other groups. NNRTI mutations were selected before switching at 1000 copies/mL (23% NNRTI-1000, 27% NNRTI-30,000). Sixty-two children started abacavir + lamivudine, 166 lamivudine + zidovudine or stavudine, and 35 other NRTIs. The abacavir + lamivudine group acquired fewest NRTI mutations. Of 60 switched to second-line, 79% PI-1000, 63% PI-30,000, 64% NNRTI-1000, and 100% NNRTI-30,000 were <400 copies/mL 24 weeks later. Children on first-line NNRTI-based ART who were randomized to switch at a higher virologic threshold developed the most resistance, yet resuppressed on second-line. An abacavir + lamivudine NRTI combination seemed

  2. H-mode plasmas at very low aspect ratio on the Pegasus Toroidal Experiment

    DOE PAGES

    Thome, Kathleen E.; Bongard, Michael W.; Barr, Jayson L.; ...

    2016-09-30

    H-mode is obtained atmore » $$A\\sim 1.2$$ in the Pegasus Toroidal Experiment via Ohmic heating, high-field-side fueling, and low edge recycling in both limited and diverted magnetic topologies. These H-mode plasmas show the formation of edge current and pressure pedestals and a doubling of the energy confinement time to $${{H}_{98y,2}}\\sim 1$$ . The L–H power threshold $${{P}_{\\text{LH}}}$$ increases with density, and there is no $${{P}_{\\text{LH}}}$$ minimum observed in the attainable density space. The power threshold is equivalent in limited and diverted plasmas, consistent with the FM3 model. However, the measured $${{P}_{\\text{LH}}}$$ is $$\\sim 15\\,\\,\\times $$ higher than that predicted by conventional International Tokamak Physics Activity (ITPA) scalings, and $${{P}_{\\text{LH}}}/{{P}_{\\text{ITPA}08}}$$ increases as $$A\\to 1$$ . Small ELMs are present at low input power $${{P}_{\\text{IN}}}\\sim {{P}_{\\text{LH}}}$$ , with toroidal mode number $$n\\leqslant 4$$ . At $${{P}_{\\text{IN}}}\\gg {{P}_{\\text{LH}}}$$ , they transition to large ELMs with intermediate 5 < n < 15. The dominant-n component of a large ELM grows exponentially, while other components evolve nonlinearly and can damp prior to the crash. Direct measurements of the current profile in the pedestal region show that both ELM types exhibit a generation of a current-hole, followed by a pedestal recovery. Large ELMs are shown to further expel a current-carrying filament. Small ELM suppression via injection of low levels of helical current into the edge plasma region is also indicated.« less

  3. Tuning the threshold voltage of carbon nanotube transistors by n-type molecular doping for robust and flexible complementary circuits

    PubMed Central

    Wang, Huiliang; Wei, Peng; Li, Yaoxuan; Han, Jeff; Lee, Hye Ryoung; Naab, Benjamin D.; Liu, Nan; Wang, Chenggong; Adijanto, Eric; Tee, Benjamin C.-K.; Morishita, Satoshi; Li, Qiaochu; Gao, Yongli; Cui, Yi; Bao, Zhenan

    2014-01-01

    Tuning the threshold voltage of a transistor is crucial for realizing robust digital circuits. For silicon transistors, the threshold voltage can be accurately controlled by doping. However, it remains challenging to tune the threshold voltage of single-wall nanotube (SWNT) thin-film transistors. Here, we report a facile method to controllably n-dope SWNTs using 1H-benzoimidazole derivatives processed via either solution coating or vacuum deposition. The threshold voltages of our polythiophene-sorted SWNT thin-film transistors can be tuned accurately and continuously over a wide range. Photoelectron spectroscopy measurements confirmed that the SWNT Fermi level shifted to the conduction band edge with increasing doping concentration. Using this doping approach, we proceeded to fabricate SWNT complementary inverters by inkjet printing of the dopants. We observed an unprecedented noise margin of 28 V at VDD = 80 V (70% of 1/2VDD) and a gain of 85. Additionally, robust SWNT complementary metal−oxide−semiconductor inverter (noise margin 72% of 1/2VDD) and logic gates with rail-to-rail output voltage swing and subnanowatt power consumption were fabricated onto a highly flexible substrate. PMID:24639537

  4. 77 FR 57531 - Airworthiness Directives; Stemme GmbH & Co. KG Powered Sailplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-18

    ...-0982; Directorate Identifier 2012-CE-035-AD] RIN 2120-AA64 Airworthiness Directives; Stemme GmbH & Co... directive (AD) for all Stemme GmbH & Co. KG Models S10, S10-V, and S10-VT powered sailplanes. This proposed... injury of occupants. Prompted by these findings, Stemme GmbH developed a procedure for identification of...

  5. Alteration of chemical behavior of L-ascorbic acid in combination with nickel sulfate at different pH solutions in vitro

    PubMed Central

    Maniyar, Shaheen A; Jargar, Jameel G; Das, Swastika N; Dhundasi, Salim A; Das, Kusal K

    2012-01-01

    Objective To evaluate the alteration of chemical behavior of L-ascorbic acid (vitamin C) with metal ion (nickel) at different pH solutions in vitro. Methods Spectra of pure aqueous solution of L-ascorbic acid (E mark) compound and NiSO4 (H2O) (sigma USA) were evaluated by UV visible spectrophotometer. Spectral analysis of L-ascorbic acid and nickel at various pH (2.0, 7.0, 7.4 and 8.6) at room temperature of 29 °C was recorded. In this special analysis, combined solution of L-ascorbic acid and nickel sulfate at different pH was also recorded. Results The result revealed that λmax (peak wavelength of spectra) of L-ascorbic acid at pH 2.0 was 289.0 nm whereas at neutral pH 7.0, λmax was 295.4 nm. In alkaline pH 8.6, λmax was 295.4 nm and at pH 7.4 the λmax of L-ascorbic acid remained the same as 295.4 nm. Nickel solution at acidic pH 2.0 was 394.5 nm, whereas at neutral pH 7.0 and pH 7.4 were the same as 394.5 nm. But at alkaline pH 8.6, λmax value of nickel sulfate became 392.0 nm. The combined solution of L-ascorbic acid and nickel sulfate (6 mg/mL each) at pH 2.0 showed 292.5 nm and 392.5 nm, respectively whereas at pH 7.0, L-ascorbic acid showed 296.5 nm and nickel sulfate showed 391.5 nm. At pH 7.4, L-ascorbic acid showed 297.0 nm and nickel sulfate showed 394.0 nm in the combined solution whereas at pH 8.6 (alkaline) L-ascorbic acid and nickel sulfate were showing 297.0 and 393.5 nm, respectively. Conclusions Results clearly indicate an altered chemical behavior of L-ascorbic acid either alone or in combination with nickel sulfate in vitro at different pH. Perhaps oxidation of L-ascorbic acid to L-dehydro ascorbic acid via the free radical (HSc*) generation from the reaction of H2ASc + Ni (II) is the cause of such alteration of λmax value of L-ascorbic acid in the presence of metal nickel. PMID:23569901

  6. Bayesian methods for estimating GEBVs of threshold traits

    PubMed Central

    Wang, C-L; Ding, X-D; Wang, J-Y; Liu, J-F; Fu, W-X; Zhang, Z; Yin, Z-J; Zhang, Q

    2013-01-01

    Estimation of genomic breeding values is the key step in genomic selection (GS). Many methods have been proposed for continuous traits, but methods for threshold traits are still scarce. Here we introduced threshold model to the framework of GS, and specifically, we extended the three Bayesian methods BayesA, BayesB and BayesCπ on the basis of threshold model for estimating genomic breeding values of threshold traits, and the extended methods are correspondingly termed BayesTA, BayesTB and BayesTCπ. Computing procedures of the three BayesT methods using Markov Chain Monte Carlo algorithm were derived. A simulation study was performed to investigate the benefit of the presented methods in accuracy with the genomic estimated breeding values (GEBVs) for threshold traits. Factors affecting the performance of the three BayesT methods were addressed. As expected, the three BayesT methods generally performed better than the corresponding normal Bayesian methods, in particular when the number of phenotypic categories was small. In the standard scenario (number of categories=2, incidence=30%, number of quantitative trait loci=50, h2=0.3), the accuracies were improved by 30.4%, 2.4%, and 5.7% points, respectively. In most scenarios, BayesTB and BayesTCπ generated similar accuracies and both performed better than BayesTA. In conclusion, our work proved that threshold model fits well for predicting GEBVs of threshold traits, and BayesTCπ is supposed to be the method of choice for GS of threshold traits. PMID:23149458

  7. Spectral dilation of L(B,H)-valued measures and its application to stationary dilation for Banach space valued processes

    NASA Technical Reports Server (NTRS)

    Miamee, A. G.

    1988-01-01

    Let B be a Banach space and H and K two Hilbert spaces. The spectral dilation of L(B,H)-valued measures is studied and it is shown that the recent results of Makagon and Salehi (1986) and Rosenberg (1982) on the dilation of L(K,H)-valued measures can be extended to hold for the general Banach space setting of L(B,H)-valued measures. These L(B,H)-valued measures are closely connected to the Banach space valued processes. This connection is recalled and as application of spectral dilation of L(B,H)-valued measures the well known stationary dilation results for scalar valued processes is extended to the case of Banach space valued processes.

  8. Assessment of Maximum Aerobic Capacity and Anaerobic Threshold of Elite Ballet Dancers.

    PubMed

    Wyon, Matthew A; Allen, Nick; Cloak, Ross; Beck, Sarah; Davies, Paul; Clarke, Frances

    2016-09-01

    An athlete's cardiorespiratory profile, maximal aerobic capacity, and anaerobic threshold is affected by training regimen and competition demands. The present study aimed to ascertain whether there are company rank differences in maximal aerobic capacity and anaerobic threshold in elite classical ballet dancers. Seventy-four volunteers (M 34, F 40) were recruited from two full-time professional classical ballet companies. All participants completed a continuous incremental treadmill protocol with a 1-km/hr speed increase at the end of each 1-min stage until termination criteria had been achieved (e.g., voluntary cessation, respiratory exchange ratio <1.15, HR ±5 bpm of estimated HRmax). Peak VO2 (5-breathe smooth) was recorded and anaerobic threshold calculated using ventilatory curve and ventilatory equivalents methods. Statistical analysis reported between-subject effects for gender (F1,67=35.18, p<0.001) and rank (F1,67=8.67, p<0.001); post hoc tests reported soloists (39.5±5.15 mL/kg/min) as having significantly lower VO2 peak than artists (45.9±5.75 mL/kg/min, p<0.001) and principal dancers (48.07±3.24 mL/kg/min, p<0.001). Significant differences in anaerobic threshold were reported for age (F1,67=7.68, p=0.008) and rank (F1,67=3.56, p=0.034); post hoc tests reported artists (75.8±5.45%) having significantly lower anaerobic threshold than soloists (80.9±5.71, p<0.01) and principals (84.1±4.84%, p<0.001). The observed differences in VO2 peak and anaerobic threshold between the ranks in ballet companies are probably due to the different rehearsal and performance demands.

  9. Enhanced production of L-DOPA in cell cultures of Mucuna pruriens L. and Mucuna prurita H.

    PubMed

    Raghavendra, S; Kumar, V; Ramesh, C K; Khan, M H Moinuddin

    2012-01-01

    A comparative study on the production of 3,4-dihydroxyphenylalanine (L-DOPA) was carried out in cell cultures of two Mucuna species by elicitor treatment and precursor feeding. The influence of elicitors and the precursor molecule on L-DOPA production, polyphenol oxidase (PPO) and tyrosinase activities was also studied. Callus cultures were initiated in Mucuna pruriens L. and Mucuna prurita H. on MS medium supplemented with BAP and IAA at different concentrations. Suspension cultures were established in MS liquid medium supplemented with BAP, IAA, the elicitors methyl jasmonate, chitin and pectin or the precursor L-tyrosine at different concentrations for L-DOPA production. Compared to the controls, several-fold increases in L-DOPA concentration were observed in elicitor-treated and precursor-fed suspension cultures of both plant species. L-DOPA concentrations were comparatively higher in precursor-fed cultures than those receiving elicitor treatments. A parallel increase in tyrosinase and PPO levels was also observed. Loss of cell viability was observed at high concentrations of elicitor-treated cultures, whereas L-tyrosine did not cause any cell death. Compared to elicitor treatments, precursor feeding resulted in higher concentrations of L-DOPA production and tyrosinase activity. The efficacy of L-DOPA production was found to be higher for suspension cultures of M. pruriens compared to M. prurita in all treatments.

  10. THRESHOLD LOGIC.

    DTIC Science & Technology

    synthesis procedures; a ’best’ method is definitely established. (2) ’Symmetry Types for Threshold Logic’ is a tutorial expositon including a careful...development of the Goto-Takahasi self-dual type ideas. (3) ’Best Threshold Gate Decisions’ reports a comparison, on the 2470 7-argument threshold ...interpretation is shown best. (4) ’ Threshold Gate Networks’ reviews the previously discussed 2-algorithm in geometric terms, describes our FORTRAN

  11. Properties of the low threshold Ca current in single frog atrial cardiomyocytes. A comparison with the high threshold Ca current

    PubMed Central

    1992-01-01

    The properties of the low threshold Ca current (ICaT) in bullfrog (Rana catesbeiana) isolated atrial cardiomyocytes were studied using the whole-cell recording patch-clamp technique and compared with those of the high threshold Ca current (ICaL). In 91% of atrial cells we observed both ICaT and ICaL when collagenase and trypsin were used to dissociate the cells. But when pronase was used, only 30% of the cells exhibited ICaT. ICaT was never found in ventricular cells. ICaT could be investigated more easily when ICaL was inhibited by Cd ions (50 microM). Its kinetics were unchanged by substituting Ba for Ca, or in the presence of high concentrations of Ba. Both ICaT and ICaL exhibited reduced inactivation after high depolarizing prepulses. ICaT was found to be sensitive to dihydropyridines: 1 microM nifedipine decreased this current while 1 microM BAY K 8644 increased it; this occurred without significant variations in the steady-state inactivation curve. ICaT was more sensitive than ICaL to alpha 1-adrenergic and P2-purinergic stimulations, while ICaL was more sensitive to beta-adrenergic stimulation. Isoproterenol was still able to increase ICaT in the presence of high intracellular cAMP. Both currents were increased by 1 microM ouabain (although ICaL only transiently) and decreased by 10 microM ouabain. It is concluded that the two types of Ca channels can be observed in bullfrog atrial cells and that they are specifically altered by pharmacological agents and neuromediators. This may have implications for cardiac behavior. PMID:1279097

  12. Energy Switching Threshold for Climatic Benefits

    NASA Astrophysics Data System (ADS)

    Zhang, X.; Cao, L.; Caldeira, K.

    2013-12-01

    Climate change is one of the great challenges facing humanity currently and in the future. Its most severe impacts may still be avoided if efforts are made to transform current energy systems (1). A transition from the global system of high Greenhouse Gas (GHG) emission electricity generation to low GHG emission energy technologies is required to mitigate climate change (2). Natural gas is increasingly seen as a choice for transitions to renewable sources. However, recent researches in energy and climate puzzled about the climate implications of relying more energy on natural gas. On one hand, a shift to natural gas is promoted as climate mitigation because it has lower carbon per unit energy than coal (3). On the other hand, the effect of switching to natural gas on nuclear-power and other renewable energies development may offset benefits from fuel-switching (4). Cheap natural gas is causing both coal plants and nuclear plants to close in the US. The objective of this study is to measure and evaluate the threshold of energy switching for climatic benefits. We hypothesized that the threshold ratio of energy switching for climatic benefits is related to GHGs emission factors of energy technologies, but the relation is not linear. A model was developed to study the fuel switching threshold for greenhouse gas emission reduction, and transition from coal and nuclear electricity generation to natural gas electricity generation was analyzed as a case study. The results showed that: (i) the threshold ratio of multi-energy switching for climatic benefits changes with GHGs emission factors of energy technologies. (ii)The mathematical relation between the threshold ratio of energy switching and GHGs emission factors of energies is a curved surface function. (iii) The analysis of energy switching threshold for climatic benefits can be used for energy and climate policy decision support.

  13. Ultralow-threshold Raman lasing with CaF2 resonators.

    PubMed

    Grudinin, Ivan S; Maleki, Lute

    2007-01-15

    We demonstrate efficient Raman lasing with CaF2 whispering-gallery-mode resonators. Continuous-wave emission threshold is shown to be possible below 1 microW with a 5mm cavity, which is to our knowledge orders of magnitude lower than in any other Raman source. Low-threshold lasing is made possible by the ultrahigh optical quality factor of the cavity, of the order of Q=5x10(10). Stokes components of up to the fifth order were observed at a pump power of 160 microW, and up to the eighth order at 1 mW. A lasing threshold of 15 microW was also observed in a 100 microm CaF2 microcavity. Potential applications are discussed.

  14. High efficiency 4H-SiC betavoltaic power sources using tritium radioisotopes

    NASA Astrophysics Data System (ADS)

    Thomas, Christopher; Portnoff, Samuel; Spencer, M. G.

    2016-01-01

    Realization of an 18.6% efficient 4H-silicon carbide (4H-SiC) large area betavoltaic power source using the radioisotope tritium is reported. A 200 nm 4H-SiC P+N junction is used to collect high-energy electrons. The electron source is a titanium tritide (TiH3x) foil, or an integrated titanium tritide region formed by the diffusion of tritium into titanium. The specific activity of the source is directly measured. Dark current measured under short circuit conditions was less than 6.1 pA/cm2. Samples measured with an external tritium foil produced an open circuit voltage of 2.09 V, short circuit current of 75.47 nA/cm2, fill factor of 0.86, and power efficiency of 18.6%. Samples measured with an integrated source produced power efficiencies of 12%. Simulations were done to determine the beta spectrum (modified by self absorption) exiting the source and the electron hole pair generation function in the 4H-SiC. The electron-hole pair generation function in 4H-SiC was modeled as a Gaussian distribution, and a closed form solution of the continuity equation was used to analyze the cell performance. The effective surface recombination velocity in our samples was found to be 105-106 cm/s. Our analysis demonstrated that the surface recombination dominates the performance of a tritium betavoltaic device but that using a thin P+N junction structure can mitigate some of the negative effects.

  15. The carotid baroreflex modifies the pressor threshold of the muscle metaboreflex in humans.

    PubMed

    Ichinose, Masashi; Ichinose-Kuwahara, Tomoko; Watanabe, Kazuhito; Kondo, Narihiko; Nishiyasu, Takeshi

    2017-09-01

    The purpose of the present study was to test our hypothesis that unloading the carotid baroreceptors alters the threshold and gain of the muscle metaboreflex in humans. Ten healthy subjects performed a static handgrip exercise at 50% of maximum voluntary contraction. Contraction was sustained for 15, 30, 45, and 60 s and was followed by 3 min of forearm circulatory arrest, during which forearm muscular pH is known to decrease linearly with increasing contraction time. The carotid baroreceptors were unloaded by applying 0.1-Hz sinusoidal neck pressure (oscillating from +15 to +50 mmHg) during ischemia. We estimated the threshold and gain of the muscle metaboreflex by analyzing the relationship between the cardiovascular responses during ischemia and the amount of work done during the exercise. In the condition with unloading of the carotid baroreceptors, the muscle metaboreflex thresholds for mean arterial blood pressure (MAP) and total vascular resistance (TVR) corresponded to significantly lower work levels than the control condition (threshold for MAP: 795 ± 102 vs. 662 ± 208 mmHg and threshold for TVR: 818 ± 213 vs. 572 ± 292 kg·s, P < 0.05), but the gains did not differ between the two conditions (gain for MAP: 4.9 ± 1.7 vs. 4.4 ± 1.6 mmHg·kg·s -1 ·100 and gain for TVR: 1.3 ± 0.8 vs. 1.3 ± 0.7 mmHg·l -1 ·min -1 ·kg·s -1 ·100). We conclude that the carotid baroreflex modifies the muscle metaboreflex threshold in humans. Our results suggest the carotid baroreflex brakes the muscle metaboreflex, thereby inhibiting muscle metaboreflex-mediated pressor and vasoconstriction responses. NEW & NOTEWORTHY We found that unloading the carotid baroreceptors shifts the pressor threshold of the muscle metaboreflex toward lower metabolic stimulation levels in humans. This finding indicates that, in the normal loading state, the carotid baroreflex inhibits the muscle metaboreflex pressor response by shifting the reflex threshold to higher metabolic stimulation

  16. E3 Success Story - Rising Above the Rest: H&L Advantage

    EPA Pesticide Factsheets

    Through the Green Suppliers Network review process, H&L Advantage worked on site with Michigan's Department of Environmental Quality (DEQ) and The Right Place, to identify over a dozen improvement opportunities in August 2004.

  17. Gravitational star formation thresholds and gas density in three galaxies

    NASA Technical Reports Server (NTRS)

    Oey, M. S.; Kennicutt, R. C., Jr.

    1990-01-01

    It has long been held that the star formation rate (SFR) may be described as a power law of the gas density, p(exp n), as given by Schmidt (1959). However, this relation has as yet remained poorly defined and is likewise poorly understood. In particular, most studies have been investigations of global gas and star formation properties of galaxies, due to lack of adequate high-resolution data for detailed studies of individual galaxies. The three spiral galaxies in this study have published maps of both H2 (as traced by CO), and HI, thereby enabling the authors to investigate the relationship between total gas surface density and SFR. The purpose of the present investigation is the comparison of spatially-resolved total surface gas density in three galaxies (NGC 6946, M51, and M83) to sigma sub c as given by the above model. CO, HI and H alpha data for NGC 6946 were taken from Tacconi-Garman (1988), and for M51 and M83 from Lord (1987). The authors used a CO-H2 conversion of N(H2)/I sub CO(exp cos i = 2.8 x 10(exp 20) atoms cm(-2)/(K kms(-1), and summed the H2 and HI data for each galaxy to obtain the total hydrogen gas density. This total was then multiplied by a factor of 1.36 to include the contribution of helium to the total surface gas density. The authors assumed distances to NGC 6946, M51, and M83 to be 6.0, 9.6, and 8.9 Mpc respectively, with inclination angles of 30, 20, and 26 degrees. H alpha flux was used as the measure of SFR for NGC 6946, and SFR for the remaining two galaxies was taken directly from Lord as computed from H alpha measurements. The results of these full-disk studies thus show a remarkable correlation between the total gas density and the threshold densities given by the gravitational stability criterion. In particular, the threshold density appears to mark a lower boundary to the range of gas densities in these galaxies, which may have consequence in determining appropriate models for star formation and gas dynamics. More evidence is

  18. Measurement of beauty photoproduction near threshold using di-electron events with the H1 detector at HERA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aaron, F. D.; Alexa, C.; Andreev, V.

    The cross section formore » $$ep \\to e b\\bar{b} X$$ in photoproduction is measured with the H1 detector at the $ep$-collider HERA. The decay channel $$b\\bar{b} \\to ee X^\\prime$$ is selected by identifying the semi-electronic decays of the b-quarks. The total production cross section is measured in the kinematic range given by the photon virtuality $$Q^2 \\le 1 GeV^2$$, the inelasticity $$0.05 \\le y \\le 0.65$$ and the pseudorapidity of the $b$-quarks $$|\\eta(b)|$$,$$|\\eta(\\bar{b})| \\le 2$$. The differential production cross section is measured as a function of the average transverse momentum of the beauty quarks <$$P_T$$(b)> down to the threshold. The results are compared to next-to-leading-order QCD predictions.« less

  19. Novel self-powered pH indicator using ionic polymeric gel muscles

    NASA Astrophysics Data System (ADS)

    Shahinpoor, Mohsen

    1994-05-01

    A novel design for a torsional spring-loaded pH indicator using ionic polymeric gel fibrous muscles is presented. The essential parts of the proposed self-powered pH indicator are a pair of co-axial and concentric cylinders, an assembly of fibrous polyacrylonitrile (PAN) muscles, a torsional spring, and a dial indicator. The two co-axial cylinders are such that the inner cylinder may pivotally rotate about the central rotation axis that is fixed to the inner bottom or side of the outer cylinder. The outer cylinder also serves as a reservoir for any liquid whose pH is to be determined either statically or dynamically. The internal cylindrical drum is further equipped with a dial indicator on one of its outer end caps such that when a pH environment is present the contraction or expansion of the PAN fibers cause the inner drum to rotate and thus give a reading of the dial indicator. The motion of the dial indicator may also be converted to an electrical signal (voltage) for digital electronics display and computer control. A mathematical model is also presented for the dynamic response of the self-powered pH indicator made with contractile PAN fiber bundle assemblies.

  20. Pain thresholds, supra-threshold pain and lidocaine sensitivity in patients with erythromelalgia, including the I848Tmutation in NaV 1.7.

    PubMed

    Helås, T; Sagafos, D; Kleggetveit, I P; Quiding, H; Jönsson, B; Segerdahl, M; Zhang, Z; Salter, H; Schmelz, M; Jørum, E

    2017-09-01

    Nociceptive thresholds and supra-threshold pain ratings as well as their reduction upon local injection with lidocaine were compared between healthy subjects and patients with erythromelalgia (EM). Lidocaine (0.25, 0.50, 1.0 or 10 mg/mL) or placebo (saline) was injected intradermally in non-painful areas of the lower arm, in a randomized, double-blind manner, to test the effect on dynamic and static mechanical sensitivity, mechanical pain sensitivity, thermal thresholds and supra-threshold heat pain sensitivity. Heat pain thresholds and pain ratings to supra-threshold heat stimulation did not differ between EM-patients (n = 27) and controls (n = 25), neither did the dose-response curves for lidocaine. Only the subgroup of EM-patients with mutations in sodium channel subunits Na V 1.7, 1.8 or 1.9 (n = 8) had increased lidocaine sensitivity for supra-threshold heat stimuli, contrasting lower sensitivity to strong mechanical stimuli. This pattern was particularly clear in the two patients carrying the Na V 1.7 I848T mutations in whom lidocaine's hyperalgesic effect on mechanical pain sensitivity contrasted more effective heat analgesia. Heat pain thresholds are not sensitized in EM patients, even in those with gain-of-function mutations in Na V 1.7. Differential lidocaine sensitivity was overt only for noxious stimuli in the supra-threshold range suggesting that sensitized supra-threshold encoding is important for the clinical pain phenotype in EM in addition to lower activation threshold. Intracutaneous lidocaine dose-dependently blocked nociceptive sensations, but we did not identify EM patients with particular high lidocaine sensitivity that could have provided valuable therapeutic guidance. Acute pain thresholds and supra-threshold heat pain in controls and patients with erythromelalgia do not differ and have the same lidocaine sensitivity. Acute heat pain thresholds even in EM patients with the Na V 1.7 I848T mutation are normal and only nociceptor

  1. Anatomy of filamentary threshold switching in amorphous niobium oxide.

    PubMed

    Li, Shuai; Liu, Xinjun; Nandi, Sanjoy Kumar; Elliman, Robert Glen

    2018-06-25

    The threshold switching behaviour of Pt/NbOx/TiN devices is investigated as a function device area and NbOx film thickness and shown to reveal important insight into the structure of the self-assembled switching region. The devices exhibit combined selector-memory (1S1R) behavior after an initial voltage-controlled forming process, but exhibit symmetric threshold switching when the RESET and SET currents are kept below a critical value. In this mode, the threshold and hold voltages are independent of the device area and film thickness but the threshold current (power), while independent of device area, decreases with increasing film thickness. These results are shown to be consistent with a structure in which the threshold switching volume is confined, both laterally and vertically, to the region between the residual memory filament and the TiN electrode, and where the memory filament has a core-shell structure comprising a metallic core and a semiconducting shell. The veracity of this structure is demonstrated by comparing experimental results with the predictions of a simple circuit model, and more detailed finite element simulations. These results provide further insight into the structure and operation of NbOx threshold switching devices that have application in emerging memory and neuromorphic computing fields. © 2018 IOP Publishing Ltd.

  2. Higgs-stoponium mixing near the stop-antistop threshold

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bodwin, Geoffrey T.; Chung, Hee Sok; Wagner, Carlos E. M.

    Supersymmetric extensions of the standard model contain additional heavy neutral Higgs bosons that are coupled to heavy scalar top quarks (stops). This system exhibits interesting field theoretic phenomena when the Higgs mass is close to the stop-antistop production threshold. Existing work in the literature has examined the digluon-to-diphoton cross section near threshold and has focused on enhancements in the cross section that might arise either from the perturbative contributions to the Higgs-to-digluon and Higgs-to-diphoton form factors or from mixing of the Higgs boson with stoponium states. Near threshold, enhancements in the relevant amplitudes that go as inverse powers of themore » stop-antistop relative velocity require resummations of perturbation theory and/or nonperturbative treatments. We present a complete formulation of threshold effects at leading order in the stop-antistop relative velocity in terms of nonrelativistic effective field theory. We give detailed numerical calculations for the case in which the stop-antistop Green’s function is modeled with a Coulomb-Schr¨odinger Green’s function. We find several general effects that do not appear in a purely perturbative treatment. Higgs-stop-antistop mixing effects displace physical masses from the threshold region, thereby rendering the perturbative threshold enhancements inoperative. In the case of large Higgs-stop-antistop couplings, the displacement of a physical state above threshold substantially increases its width, owing to its decay width to a stop-antistop pair, and greatly reduces its contribution to the cross section.« less

  3. Ultra high voltage MOS controlled 4H-SiC power switching devices

    NASA Astrophysics Data System (ADS)

    Ryu, S.; Capell, C.; Van Brunt, E.; Jonas, C.; O'Loughlin, M.; Clayton, J.; Lam, K.; Pala, V.; Hull, B.; Lemma, Y.; Lichtenwalner, D.; Zhang, Q. J.; Richmond, J.; Butler, P.; Grider, D.; Casady, J.; Allen, S.; Palmour, J.; Hinojosa, M.; Tipton, C. W.; Scozzie, C.

    2015-08-01

    Ultra high voltage (UHV, >15 kV) 4H-silicon carbide (SiC) power devices have the potential to significantly improve the system performance, reliability, and cost of energy conversion systems by providing reduced part count, simplified circuit topology, and reduced switching losses. In this paper, we compare the two MOS based UHV 4H-SiC power switching devices; 15 kV 4H-SiC MOSFETs and 15 kV 4H-SiC n-IGBTs. The 15 kV 4H-SiC MOSFET shows a specific on-resistance of 204 mΩ cm2 at 25 °C, which increased to 570 mΩ cm2 at 150 °C. The 15 kV 4H-SiC MOSFET provides low, temperature-independent, switching losses which makes the device more attractive for applications that require higher switching frequencies. The 15 kV 4H-SiC n-IGBT shows a significantly lower forward voltage drop (VF), along with reasonable switching performance, which make it a very attractive device for high voltage applications with lower switching frequency requirements. An electrothermal analysis showed that the 15 kV 4H-SiC n-IGBT outperforms the 15 kV 4H-SiC MOSFET for applications with switching frequencies of less than 5 kHz. It was also shown that the use of a carrier storage layer (CSL) can significantly improve the conduction performance of the 15 kV 4H-SiC n-IGBTs.

  4. An observational investigation of the identity of B11244 (l-C{sub 3}H{sup +}/C{sub 3}H{sup -})

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGuire, Brett A.; Carroll, P. Brandon; Gratier, Pierre

    Pety et al. have reported the detection of eight transitions of a closed-shell, linear molecule (B11244) in observations toward the Horsehead photodissociation region (PDR), which they attribute to the l-C{sub 3}H{sup +} cation. Recent high-level ab initio calculations have called this assignment into question; the anionic C{sub 3}H{sup –} molecule has been suggested as a more likely candidate. Here, we examine observations of the Horsehead PDR, Sgr B2(N), TMC-1, and IRC+10216 in the context of both l-C{sub 3}H{sup +} and C{sub 3}H{sup –}. We find no observational evidence of K{sub a} = 1 lines, which should be present were themore » carrier indeed C{sub 3}H{sup –}. Additionally, we find a strong anticorrelation between the presence of known molecular anions and B11244 in these regions. Finally, we discuss the formation and destruction chemistry of C{sub 3}H{sup –} in the context of the physical conditions in the regions. Based on these results, we conclude there is little evidence to support the claim that the carrier is C{sub 3}H{sup –}.« less

  5. Robust optimization of the laser induced damage threshold of dielectric mirrors for high power lasers.

    PubMed

    Chorel, Marine; Lanternier, Thomas; Lavastre, Éric; Bonod, Nicolas; Bousquet, Bruno; Néauport, Jérôme

    2018-04-30

    We report on a numerical optimization of the laser induced damage threshold of multi-dielectric high reflection mirrors in the sub-picosecond regime. We highlight the interplay between the electric field distribution, refractive index and intrinsic laser induced damage threshold of the materials on the overall laser induced damage threshold (LIDT) of the multilayer. We describe an optimization method of the multilayer that minimizes the field enhancement in high refractive index materials while preserving a near perfect reflectivity. This method yields a significant improvement of the damage resistance since a maximum increase of 40% can be achieved on the overall LIDT of the multilayer.

  6. Competitive photodissociation channels in jet-cooled HNCO: Thermochemistry and near-threshold predissociation

    NASA Astrophysics Data System (ADS)

    Zyrianov, M.; Droz-Georget, Th.; Sanov, A.; Reisler, H.

    1996-11-01

    The photoinitiated unimolecular decomposition of jet-cooled HNCO has been studied following S1(1A″)←S0(1A') excitation near the thresholds of the spin-allowed dissociation channels: (1) H(2S)+NCO(X2Π) and (2) NH(a1Δ)+CO(X1Σ+), which are separated by 4470 cm-1. Photofragment yield spectra of NCO(X2Π) and NH (a1Δ) were obtained in selected regions in the 260-220 nm photolysis range. The NCO(X2Π)yield rises abruptly at 38 380 cm-1 and the spectrum exhibits structures as narrow as 0.8 cm-1 near the threshold. The linewidths increase only slowly with photolysis energy. The jet-cooled absorption spectrum near the channel (1) threshold [D0(H+NCO)] was obtained using two-photon excitation via the S1 state, terminating in a fluorescent product. The absorption spectrum is similar to the NCO yield spectrum, and its intensity does not diminish noticeably above D0(H+NCO), indicating that dissociation near threshold is slow. The NCO product near threshold is cold, as is typical of a barrierless reaction. NH (a1Δ) products appear first at 42 840 cm-1, but their yield is initially very small, as evidenced also by the insignificant decrease in the NCO yield in the threshold region of channel (2). The NH (a1Δ) yield increases faster at higher photolysis energies and the linewidths increase as well. At the channel (2) threshold, the NH (a1Δ) product is generated only in the lowest rotational level, J=2, and rotational excitation increases with photolysis energy. We propose that in the range 260-230 nm, HNCO (S1) undergoes radiationless decay terminating in S0/T1 followed by unimolecular reaction. Decompositions via channels (1) and (2) proceed without significant exit channel barriers. At wavelengths shorter than 230 nm, the participation of an additional, direct pathway cannot be ruled out. The jet-cooled photofragment yield spectra allow the determination, with good accuracy, of thermochemical values relevant to HNCO decomposition. The following heats of formation are

  7. Threshold quantum cryptography

    NASA Astrophysics Data System (ADS)

    Tokunaga, Yuuki; Okamoto, Tatsuaki; Imoto, Nobuyuki

    2005-01-01

    We present the concept of threshold collaborative unitary transformation or threshold quantum cryptography, which is a kind of quantum version of threshold cryptography. Threshold quantum cryptography states that classical shared secrets are distributed to several parties and a subset of them, whose number is greater than a threshold, collaborates to compute a quantum cryptographic function, while keeping each share secretly inside each party. The shared secrets are reusable if no cheating is detected. As a concrete example of this concept, we show a distributed protocol (with threshold) of conjugate coding.

  8. Electrocardiogram signal denoising based on a new improved wavelet thresholding

    NASA Astrophysics Data System (ADS)

    Han, Guoqiang; Xu, Zhijun

    2016-08-01

    Good quality electrocardiogram (ECG) is utilized by physicians for the interpretation and identification of physiological and pathological phenomena. In general, ECG signals may mix various noises such as baseline wander, power line interference, and electromagnetic interference in gathering and recording process. As ECG signals are non-stationary physiological signals, wavelet transform is investigated to be an effective tool to discard noises from corrupted signals. A new compromising threshold function called sigmoid function-based thresholding scheme is adopted in processing ECG signals. Compared with other methods such as hard/soft thresholding or other existing thresholding functions, the new algorithm has many advantages in the noise reduction of ECG signals. It perfectly overcomes the discontinuity at ±T of hard thresholding and reduces the fixed deviation of soft thresholding. The improved wavelet thresholding denoising can be proved to be more efficient than existing algorithms in ECG signal denoising. The signal to noise ratio, mean square error, and percent root mean square difference are calculated to verify the denoising performance as quantitative tools. The experimental results reveal that the waves including P, Q, R, and S waves of ECG signals after denoising coincide with the original ECG signals by employing the new proposed method.

  9. Investigation into the formation of the scrape-off layer density shoulder in JET ITER-like wall L-mode and H-mode plasmas

    NASA Astrophysics Data System (ADS)

    Wynn, A.; Lipschultz, B.; Cziegler, I.; Harrison, J.; Jaervinen, A.; Matthews, G. F.; Schmitz, J.; Tal, B.; Brix, M.; Guillemaut, C.; Frigione, D.; Huber, A.; Joffrin, E.; Kruzei, U.; Militello, F.; Nielsen, A.; Walkden, N. R.; Wiesen, S.; Contributors, JET

    2018-05-01

    The low temperature boundary layer plasma (scrape-off layer or SOL) between the hot core and the surrounding vessel determines the level of power loading, erosion and implantation of material surfaces, and thus the viability of tokamak-based fusion as an energy source. This study explores mechanisms affecting the formation of flattened density profiles, so-called ‘density shoulders’, in the low-field side (LFS) SOL, which modify ion and neutral fluxes to surfaces—and subsequent erosion. We find that increases in SOL parallel resistivity, Λdiv (=[L || ν eiΩi]/c sΩe), postulated to lead to shoulder growth through changes in SOL turbulence characteristics, correlates with increases in SOL shoulder amplitude, A s, only under a subset of conditions (D2-fuelled L-mode density scans with outer strike point on the horizontal target). Λdiv fails to correlate with A s for cases of N2 seeding or during sweeping of the strike point across the horizontal target. The limited correlation of Λdiv and A s is also found for H-mode discharges. Thus, while it may be necessary for Λdiv to be above a threshold of ~1 for shoulder formation and/or growth, another mechanism is required. More significantly, we find that in contrast to parallel resistivity, outer divertor recycling, as quantified by the total outer divertor Balmer D α emission, I-D α , does scale with A s where Λdiv does and even where Λdiv does not. Divertor recycling could lead to SOL density shoulder formation through: (a) reducing the parallel to the field flow (loss) of ions out of the SOL to the divertor; and (b) changes in radial electric fields which lead to E  ×  B poloidal flows as well as potentially affecting SOL turbulence birth characteristics. Thus, changes in divertor recycling may be the sole process involved in bringing about SOL density shoulders or it may be that it acts in tandem with parallel resistivity.

  10. Non-Markovian Infection Spread Dramatically Alters the Susceptible-Infected-Susceptible Epidemic Threshold in Networks

    NASA Astrophysics Data System (ADS)

    Van Mieghem, P.; van de Bovenkamp, R.

    2013-03-01

    Most studies on susceptible-infected-susceptible epidemics in networks implicitly assume Markovian behavior: the time to infect a direct neighbor is exponentially distributed. Much effort so far has been devoted to characterize and precisely compute the epidemic threshold in susceptible-infected-susceptible Markovian epidemics on networks. Here, we report the rather dramatic effect of a nonexponential infection time (while still assuming an exponential curing time) on the epidemic threshold by considering Weibullean infection times with the same mean, but different power exponent α. For three basic classes of graphs, the Erdős-Rényi random graph, scale-free graphs and lattices, the average steady-state fraction of infected nodes is simulated from which the epidemic threshold is deduced. For all graph classes, the epidemic threshold significantly increases with the power exponents α. Hence, real epidemics that violate the exponential or Markovian assumption can behave seriously differently than anticipated based on Markov theory.

  11. High efficiency 4H-SiC betavoltaic power sources using tritium radioisotopes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, Christopher; Portnoff, Samuel; Spencer, M. G.

    Realization of an 18.6% efficient 4H-silicon carbide (4H-SiC) large area betavoltaic power source using the radioisotope tritium is reported. A 200 nm 4H-SiC P{sup +}N junction is used to collect high-energy electrons. The electron source is a titanium tritide (TiH{sup 3}{sub x}) foil, or an integrated titanium tritide region formed by the diffusion of tritium into titanium. The specific activity of the source is directly measured. Dark current measured under short circuit conditions was less than 6.1 pA/cm{sup 2}. Samples measured with an external tritium foil produced an open circuit voltage of 2.09 V, short circuit current of 75.47 nA/cm{sup 2}, fill factor of 0.86,more » and power efficiency of 18.6%. Samples measured with an integrated source produced power efficiencies of 12%. Simulations were done to determine the beta spectrum (modified by self absorption) exiting the source and the electron hole pair generation function in the 4H-SiC. The electron-hole pair generation function in 4H-SiC was modeled as a Gaussian distribution, and a closed form solution of the continuity equation was used to analyze the cell performance. The effective surface recombination velocity in our samples was found to be 10{sup 5}–10{sup 6 }cm/s. Our analysis demonstrated that the surface recombination dominates the performance of a tritium betavoltaic device but that using a thin P{sup +}N junction structure can mitigate some of the negative effects.« less

  12. Simulation of RF power and multi-cusp magnetic field requirement for H- ion sources

    NASA Astrophysics Data System (ADS)

    Pathak, Manish; Senecha, V. K.; Kumar, Rajnish; Ghodke, Dharmraj. V.

    2016-12-01

    A computer simulation study for multi-cusp RF based H- ion source has been carried out using energy and particle balance equation for inductively coupled uniformly dense plasma considering sheath formation near the boundary wall of the plasma chamber for RF ion source used as high current injector for 1 Gev H- Linac project for SNS applications. The average reaction rates for different reactions responsible for H- ion production and destruction have been considered in the simulation model. The RF power requirement for the caesium free H- ion source for a maximum possible H- ion beam current has been derived by evaluating the required current and RF voltage fed to the coil antenna using transformer model for Inductively Coupled Plasma (ICP). Different parameters of RF based H- ion source like excited hydrogen molecular density, H- ion density, RF voltage and current of RF antenna have been calculated through simulations in the presence and absence of multicusp magnetic field to distinctly observe the effect of multicusp field. The RF power evaluated for different H- ion current values have been compared with the experimental reported results showing reasonably good agreement considering the fact that some RF power will be reflected from the plasma medium. The results obtained have helped in understanding the optimum field strength and field free regions suitable for volume emission based H- ion sources. The compact RF ion source exhibits nearly 6 times better efficiency compare to large diameter ion source.

  13. Monoclonal antibody against recombinant Fasciola gigantica cathepsin L1H could detect juvenile and adult cathepsin Ls of Fasciola gigantica.

    PubMed

    Wongwairot, Sirima; Kueakhai, Pornanan; Changklungmoa, Narin; Jaikua, Wipaphorn; Sansri, Veerawat; Meemon, Krai; Songkoomkrong, Sineenart; Riengrojpitak, Suda; Sobhon, Prasert

    2015-01-01

    Cathepsin Ls (CatLs), the major cysteine protease secreted by Fasciola spp., are important for parasite digestion and tissue invasion. Fasciola gigantica cathepsin L1H (FgCatL1H) is the isotype expressed in the early stages for migration and invasion. In the present study, a monoclonal antibody (MoAb) against recombinant F. gigantica cathepsin L1H (rFgCatL1H) was produced by hybridoma technique using spleen cells from BALB/c mice immunized with recombinant proFgCatL1H (rproFgCatL1H). This MoAb is an immunoglobulin (Ig)G1 with κ light chain isotype. The MoAb reacted specifically with rproFgCatL1H, the native FgCatL1H at a molecular weight (MW) 38 to 48 kDa in the extract of whole body (WB) of metacercariae and newly excysted juvenile (NEJ) and cross-reacted with rFgCatL1 and native FgCatLs at MW 25 to 28 kDa in WB of 2- and 4-week-old juveniles, adult, and adult excretory-secretory (ES) fractions by immunoblotting and indirect ELISA. It did not cross-react with antigens in WB fractions from other parasites, including Gigantocotyle explanatum, Paramphistomum cervi, Gastrothylax crumenifer, Eurytrema pancreaticum, Setaria labiato-papillosa, and Fischoederius cobboldi. By immunolocalization, MoAb against rFgCatL1H reacted with the native protein in the gut of metacercariae and NEJ and also cross-reacted with CatL1 in 2- and 4-week-old juveniles and adult F. gigantica. Therefore, FgCatL1H and its MoAb may be used for immunodiagnosis of both early and late fasciolosis in ruminants and humans.

  14. Conduction-band valley spin splitting in single-layer H-T l2O

    NASA Astrophysics Data System (ADS)

    Ma, Yandong; Kou, Liangzhi; Du, Aijun; Huang, Baibiao; Dai, Ying; Heine, Thomas

    2018-02-01

    Despite numerous studies, coupled spin and valley physics is currently limited to two-dimensional (2D) transition-metal dichalcogenides (TMDCs). Here, we predict an exceptional 2D valleytronic material associated with the spin-valley coupling phenomena beyond 2D TMDCs—single-layer (SL) H-T l2O . It displays large valley spin splitting (VSS), significantly larger than that of 2D TMDCs, and a finite band gap, which are both critically attractive for the integration of valleytronics and spintronics. More importantly, in sharp contrast to all the experimentally confirmed 2D valleytronic materials, where the strong valence-band VSS (0.15-0.46 eV) supports the spin-valley coupling, the VSS in SL H-T l2O is pronounced in its conduction band (0.61 eV), but negligibly small in its valence band (21 meV), thus opening a way for manipulating the coupled spin and valley physics. Moreover, SL H-T l2O possesses extremely high carrier mobility, as large as 9.8 ×103c m2V-1s-1 .

  15. Limit cycle oscillations at the L-I-H transition in TJ-II plasmas: triggering, temporal ordering and radial propagation

    NASA Astrophysics Data System (ADS)

    Estrada, T.; Ascasíbar, E.; Blanco, E.; Cappa, A.; Castejón, F.; Hidalgo, C.; van Milligen, B. Ph.; Sánchez, E.

    2015-06-01

    The spatiotemporal evolution of the interaction between turbulence and flows has been studied close to the L-H transition threshold conditions in the edge of TJ-II plasmas. As in other devices the temporal dynamics of the interaction displays limit cycle oscillations (LCO) with a characteristic predator-prey relationship between flows and turbulence. At TJ-II, the turbulence-flow front is found to propagate radially outwards at the onset of the LCO and in some particular cases, after a short time interval without oscillations, a reversal in the front propagation velocity is observed. Associated to this velocity reversal, a change in the temporal ordering of the LCO is measured. However, the change in the temporal ordering is not related to an intrinsic change in the nature of the LCO. In all cases the turbulence increase leads the process and produces an increase in the E × B flow shear. Dedicated experiments have been carried out to investigate the physical mechanisms triggering the onset of the LCO. At TJ-II the LCO are preferentially observed close to the transition threshold conditions at specific magnetic configurations having a low order rational surface located at the inner side of the E × B flow shear location. The behaviour of different frequency modes has been analysed and interpreted in terms of a geodesic acoustic mode generated by the non-linear mode coupling of Alfvén eigenmodes that evolves towards a low frequency flow, plus a MHD mode linked to the low order rational surface, as precursors of the LCO.

  16. Highly excited bound-state resonances of short-range inverse power-law potentials

    NASA Astrophysics Data System (ADS)

    Hod, Shahar

    2017-11-01

    We study analytically the radial Schrödinger equation with long-range attractive potentials whose asymptotic behaviors are dominated by inverse power-law tails of the form V(r)=-β _n r^{-n} with n>2. In particular, assuming that the effective radial potential is characterized by a short-range infinitely repulsive core of radius R, we derive a compact analytical formula for the threshold energy E^{ {max}}_l=E^{ {max}}_l(n,β _n,R), which characterizes the most weakly bound-state resonance (the most excited energy level) of the quantum system.

  17. Way-Scaling to Reduce Power of Cache with Delay Variation

    NASA Astrophysics Data System (ADS)

    Goudarzi, Maziar; Matsumura, Tadayuki; Ishihara, Tohru

    The share of leakage in cache power consumption increases with technology scaling. Choosing a higher threshold voltage (Vth) and/or gate-oxide thickness (Tox) for cache transistors improves leakage, but impacts cell delay. We show that due to uncorrelated random within-die delay variation, only some (not all) of cells actually violate the cache delay after the above change. We propose to add a spare cache way to replace delay-violating cache-lines separately in each cache-set. By SPICE and gate-level simulations in a commercial 90nm process, we show that choosing higher Vth, Tox and adding one spare way to a 4-way 16KB cache reduces leakage power by 42%, which depending on the share of leakage in total cache power, gives up to 22.59% and 41.37% reduction of total energy respectively in L1 instruction- and L2 unified-cache with a negligible delay penalty, but without sacrificing cache capacity or timing-yield.

  18. Toward power scaling in an acetylene mid-infrared hollow-core optical fiber gas laser: effects of pressure, fiber length, and pump power

    NASA Astrophysics Data System (ADS)

    Weerasinghe, H. W. Kushan; Dadashzadeh, Neda; Thirugnanasambandam, Manasadevi P.; Debord, Benoît.; Chafer, Matthieu; Gérôme, Frédéric; Benabid, Fetah; Corwin, Kristan L.; Washburn, Brian R.

    2018-02-01

    The effect of gas pressure, fiber length, and optical pump power on an acetylene mid-infrared hollow-core optical fiber gas laser (HOFGLAS) is experimentally determined in order to scale the laser to higher powers. The absorbed optical power and threshold power are measured for different pressures providing an optimum pressure for a given fiber length. We observe a linear dependence of both absorbed pump energy and lasing threshold for the acetylene HOFGLAS, while maintaining a good mode quality with an M-squared of 1.15. The threshold and mode behavior are encouraging for scaling to higher pressures and pump powers.

  19. Inhibition of Na+/H+ exchanger enhances low pH-induced L-selectin shedding and β2-integrin surface expression in human neutrophils

    PubMed Central

    Kaba, Nubia K.; Schultz, Joanne; Law, Foon-Yee; Lefort, Craig T.; Martel-Gallegos, Guadalupe; Kim, Minsoo; Waugh, Richard E.; Arreola, Jorge; Knauf, Philip A.

    2008-01-01

    Ischemia-reperfusion injury is a common pathological occurrence causing tissue damage in heart attack and stroke. Entrapment of neutrophils in the vasculature during ischemic events has been implicated in this process. In this study, we examine the effects that lactacidosis and consequent reductions in intracellular pH (pHi) have on surface expression of adhesion molecules on neutrophils. When human neutrophils were exposed to pH 6 lactate, there was a marked decrease in surface L-selectin (CD62L) levels, and the decrease was significantly enhanced by inclusion of Na+/H+ exchanger (NHE) inhibitor 5-(N,N-hexamethylene)amiloride (HMA). Similar effects were observed when pHi was reduced while maintaining normal extracellular pH, by using an NH4Cl prepulse followed by washes and incubation in pH 7.4 buffer containing NHE inhibitors [HMA, cariporide, or 5-(N,N-dimethyl)amiloride (DMA)]. The amount of L-selectin shedding induced by different concentrations of NH4Cl in the prepulse correlated with the level of intracellular acidification with an apparent pK of 6.3. In contrast, β2-integrin (CD11b and CD18) was only slightly upregulated in the low-pHi condition and was enhanced by NHE inhibition to a much lesser extent. L-selectin shedding was prevented by treating human neutrophils with inhibitors of extracellular metalloproteases (RO-31-9790 and KD-IX-73-4) or with inhibitors of intracellular signaling via p38 MAP kinase (SB-203580 and SB-239063), implying a transmembrane effect of pHi. Taken together, these data suggest that the ability of NHE inhibitors such as HMA to reduce ischemia-reperfusion injury may be related to the nearly complete removal of L-selectin from the neutrophil surface. PMID:18829897

  20. Analyzing powers in the three-body break-up reactions from 3overlineHe + 2H

    NASA Astrophysics Data System (ADS)

    Okumuşoǧlu, Nazmi T.; Basak, A. K.; Blyth, C. O.

    1980-11-01

    Analyzing powers and cross sections of the 2H( 3overlineHe, pp ) 3H, 2H( 3overlineHe, pt) 1H and2H( 3overlineHe, p 3He) n reactions have been measured as a function of the energy of the detected proton. Two of the outgoing particles were identified and detected in coincidence with several forward-angle geometries. The analyzing powers found were generally small but non-zero. However, at kinematical conditions favoring the final-state interactions between proton and triton (or neutron and helion) large values up to 0.4 were found. The results are discussed with respect to the level structure of 4He.

  1. Low threshold and high efficiency solar-pumped laser with Fresnel lens and a grooved Nd:YAG rod

    NASA Astrophysics Data System (ADS)

    Guan, Zhe; Zhao, Changming; Yang, Suhui; Wang, Yu; Ke, Jieyao; Gao, Fengbin; Zhang, Haiyang

    2016-11-01

    Sunlight is considered as a new efficient source for direct optical-pumped solid state lasers. High-efficiency solar pumped lasers with low threshold power would be more promising than semiconductor lasers with large solar panel in space laser communication. Here we report a significant advance in solar-pumped laser threshold by pumping Nd:YAG rod with a grooved sidewall. Two-solar pumped laser setups are devised. In both cases, a Fresnel lens is used as the primary sunlight concentrator. Gold-plated conical cavity with a liquid light-guide lens is used as the secondary concentrator to further increase the solar energy concentration. In the first setup, solar pumping a 6mm diameter Nd:YAG rod, maximum laser power of 31.0W/m2 cw at 1064nm is produced, which is higher than the reported record, and the slope efficiency is 4.98% with the threshold power on the surface of Fresnel lens is 200 W. In the second setup, a 5 mm diameter laser rod output power is 29.8W/m2 with a slope efficiency of 4.3%. The threshold power of 102W is obtained, which is 49% lower than the former. Meanwhile, the theoretical calculating of the threshold power and slope efficiency of the solar-pumped laser has been established based on the rate-equation of a four-level system. The results of the finite element analysis by simulation software are verified in experiment. The optimization of the conical cavity by TraceProsoftware and the optimization of the laser resonator by LASCADare useful for the design of a miniaturization solar- pumped laser.

  2. With-in host dynamics of L. monocytogenes and thresholds for distinct infection scenarios.

    PubMed

    Rahman, Ashrafur; Munther, Daniel; Fazil, Aamir; Smith, Ben; Wu, Jianhong

    2018-05-26

    The case fatality and illness rates associated with L. monocytogenes continue to pose a serious public health burden despite the significant efforts and control protocol administered by private and public sectors. Due to the advance in surveillance and improvement in detection methodology, the knowledge of sources, transmission routes, growth potential in food process units and storage, effect of pH and temperature are well understood. However, the with-in host growth and transmission mechanisms of L. monocytogenes, particularly within the human host, remain unclear, largely due to the limited access to scientific experimentation on the human population. In order to provide insight towards the human immune response to the infection caused by L. monocytogenes, we develop a with-in host mathematical model. The model explains, in terms of biological parameters, the states of asymptomatic infection, mild infection and systemic infection leading to listeriosis. The activation and proliferation of T-cells are found to be critical for the susceptibility of the infection. Utilizing stability analysis and numerical simulation, the ranges of the critical parameters relative to infection states are established. Bifurcation analysis shows the impact of the differences of these parameters on the dynamics of the model. Finally, we present model applications in regards to predicting the risk potential of listeriosis relative to the susceptible human population. Copyright © 2018. Published by Elsevier Ltd.

  3. A Survey of Memristive Threshold Logic Circuits.

    PubMed

    Maan, Akshay Kumar; Jayadevi, Deepthi Anirudhan; James, Alex Pappachen

    2017-08-01

    In this paper, we review different memristive threshold logic (MTL) circuits that are inspired from the synaptic action of the flow of neurotransmitters in the biological brain. The brainlike generalization ability and the area minimization of these threshold logic circuits aim toward crossing Moore's law boundaries at device, circuits, and systems levels. Fast switching memory, signal processing, control systems, programmable logic, image processing, reconfigurable computing, and pattern recognition are identified as some of the potential applications of MTL systems. The physical realization of nanoscale devices with memristive behavior from materials, such as TiO 2 , ferroelectrics, silicon, and polymers, has accelerated research effort in these application areas, inspiring the scientific community to pursue the design of high-speed, low-cost, low-power, and high-density neuromorphic architectures.

  4. Estimating the vibration level of an L-shaped beam using power flow techniques

    NASA Technical Reports Server (NTRS)

    Cuschieri, J. M.; Mccollum, M.; Rassineux, J. L.; Gilbert, T.

    1986-01-01

    The response of one component of an L-shaped beam, with point force excitation on the other component, is estimated using the power flow method. The transmitted power from the source component to the receiver component is expressed in terms of the transfer and input mobilities at the excitation point and the joint. The response is estimated both in narrow frequency bands, using the exact geometry of the beams, and as a frequency averaged response using infinite beam models. The results using this power flow technique are compared to the results obtained using finite element analysis (FEA) of the L-shaped beam for the low frequency response and to results obtained using statistical energy analysis (SEA) for the high frequencies. The agreement between the FEA results and the power flow method results at low frequencies is very good. SEA results are in terms of frequency averaged levels and these are in perfect agreement with the results obtained using the infinite beam models in the power flow method. The narrow frequency band results from the power flow method also converge to the SEA results at high frequencies. The advantage of the power flow method is that detail of the response can be retained while reducing computation time, which will allow the narrow frequency band analysis of the response to be extended to higher frequencies.

  5. Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices

    DOEpatents

    Chassin, David P [Pasco, WA; Donnelly, Matthew K [Kennewick, WA; Dagle, Jeffery E [Richland, WA

    2011-12-06

    Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices are described. In one aspect, an electrical power distribution control method includes providing electrical energy from an electrical power distribution system, applying the electrical energy to a load, providing a plurality of different values for a threshold at a plurality of moments in time and corresponding to an electrical characteristic of the electrical energy, and adjusting an amount of the electrical energy applied to the load responsive to an electrical characteristic of the electrical energy triggering one of the values of the threshold at the respective moment in time.

  6. Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices

    DOEpatents

    Chassin, David P.; Donnelly, Matthew K.; Dagle, Jeffery E.

    2006-12-12

    Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices are described. In one aspect, an electrical power distribution control method includes providing electrical energy from an electrical power distribution system, applying the electrical energy to a load, providing a plurality of different values for a threshold at a plurality of moments in time and corresponding to an electrical characteristic of the electrical energy, and adjusting an amount of the electrical energy applied to the load responsive to an electrical characteristic of the electrical energy triggering one of the values of the threshold at the respective moment in time.

  7. On the existence of a luminosity threshold of GRB jets in massive stars

    NASA Astrophysics Data System (ADS)

    Aloy, M. A.; Cuesta-Martínez, C.; Obergaulinger, M.

    2018-05-01

    Motivated by the many associations of γ-ray bursts (GRBs) with energetic supernova (SN) explosions, we study the propagation of relativistic jets within the progenitor star in which a SN shock wave may be launched briefly before the jets start to propagate. Based on analytic considerations and verified with an extensive set of 2D axisymmetric relativistic hydrodynamic simulations, we have estimated a threshold intrinsic jet luminosity, L_j^thr, for successfully launching a jet. This threshold depends on the structure of the progenitor and, thus, it is sensitive to its mass and to its metallicity. For a prototype host of cosmological long GRBs, a low-metallicity star of 35 M⊙, it is L_j^thr˜eq 1.35× 10^{49} erg s-1. The observed equivalent isotropic γ-ray luminosity, L_{γ ,iso,BO} ˜eq 4 ɛ _γ L_j θ _BO^{-2}, crucially depends on the jet opening angle after breakout, θBO, and on the efficiency for converting the intrinsic jet luminosity into γ-radiation, ɛγ. Highly energetic jets can produce low-luminosity events if either their opening angle after the breakout is large, which is found in our models, or if the conversion efficiency of kinetic and internal energy into radiation is low enough. Beyond this theoretical analysis, we show how the presence of a SN shock wave may reduce this luminosity threshold by means of numerical simulations. We foresee that the high-energy transients released by jets produced near the luminosity threshold will be more similar to llGRBs or XRFs than to GRBs.

  8. Lutein and zeaxanthin status and auditory thresholds in a sample of young healthy adults.

    PubMed

    Wong, Jennifer C; Kaplan, Holly S; Hammond, Billy R

    2017-01-01

    Dietary carotenoids lutein (L) and zeaxanthin (Z) have been linked to improved visual and cognitive function. These effects are thought to be mediated by the presence of these pigments in critical regions of the retina and brain. There, it has been postulated that L and Z mediate improved performance by enhancing neural efficiency. The auditory system also relies on efficient segregating of signals and noise and LZ are also found in the auditory cortex. The purpose of the present study was to investigate the influence of LZ status (as assessed by the measuring levels in retina) on auditory thresholds in young non-smokers (N = 32, M = 20.72 ± 3.28 years). LZ status was determined by measuring macular pigment (MP) optical density using a standardized psychophysical technique (customized heterochromatic flicker photometry). Auditory thresholds were assessed with puretone thresholds and puretone auditory thresholds in white noise. MP density was related to many, but not all, of the puretone thresholds we tested: 250 Hz (F(6,32) = 4.36, P < 0.01), 500 Hz (F(6,32) = 2.25, P < 0.05), 1000 Hz (F(6,32) = 3.22, P < 0.05), and 6000 Hz (F(6,32) = 2.56, P < 0.05). The overall pattern of results is consistent with a role for L and Z in maintaining optimal auditory function.

  9. Model for Estimating the Threshold Mechanical Stability of Structural Cartilage Grafts Used in Rhinoplasty

    PubMed Central

    Zemek, Allison; Garg, Rohit; Wong, Brian J. F.

    2014-01-01

    Objectives/Hypothesis Characterizing the mechanical properties of structural cartilage grafts used in rhinoplasty is valuable because softer engineered tissues are more time- and cost-efficient to manufacture. The aim of this study is to quantitatively identify the threshold mechanical stability (e.g., Young’s modulus) of columellar, L-strut, and alar cartilage replacement grafts. Study Design Descriptive, focus group survey. Methods Ten mechanical phantoms of identical size (5 × 20 × 2.3 mm) and varying stiffness (0.360 to 0.85 MPa in 0.05 MPa increments) were made from urethane. A focus group of experienced rhinoplasty surgeons (n = 25, 5 to 30 years in practice) were asked to arrange the phantoms in order of increasing stiffness. Then, they were asked to identify the minimum acceptable stiffness that would still result in favorable surgical outcomes for three clinical applications: columellar, L-strut, and lateral crural replacement grafts. Available surgeons were tested again after 1 week to evaluate intra-rater consistency. Results For each surgeon, the threshold stiffness for each clinical application differed from the threshold values derived by logistic regression by no more than 0.05 MPa (accuracy to within 10%). Specific thresholds were 0.56, 0.59, and 0.49 MPa for columellar, L-strut, and alar grafts, respectively. For comparison, human nasal septal cartilage is approximately 0.8 MPa. Conclusions There was little inter- and intra-rater variation of the identified threshold values for adequate graft stiffness. The identified threshold values will be useful for the design of tissue-engineered or semisynthetic cartilage grafts for use in structural nasal surgery. PMID:20513022

  10. Threshold Determination for Local Instantaneous Sea Surface Height Derivation with Icebridge Data in Beaufort Sea

    NASA Astrophysics Data System (ADS)

    Zhu, C.; Zhang, S.; Xiao, F.; Li, J.; Yuan, L.; Zhang, Y.; Zhu, T.

    2018-05-01

    The NASA Operation IceBridge (OIB) mission is the largest program in the Earth's polar remote sensing science observation project currently, initiated in 2009, which collects airborne remote sensing measurements to bridge the gap between NASA's ICESat and the upcoming ICESat-2 mission. This paper develop an improved method that optimizing the selection method of Digital Mapping System (DMS) image and using the optimal threshold obtained by experiments in Beaufort Sea to calculate the local instantaneous sea surface height in this area. The optimal threshold determined by comparing manual selection with the lowest (Airborne Topographic Mapper) ATM L1B elevation threshold of 2 %, 1 %, 0.5 %, 0.2 %, 0.1 % and 0.05 % in A, B, C sections, the mean of mean difference are 0.166 m, 0.124 m, 0.083 m, 0.018 m, 0.002 m and -0.034 m. Our study shows the lowest L1B data of 0.1 % is the optimal threshold. The optimal threshold and manual selections are also used to calculate the instantaneous sea surface height over images with leads, we find that improved methods has closer agreement with those from L1B manual selections. For these images without leads, the local instantaneous sea surface height estimated by using the linear equations between distance and sea surface height calculated over images with leads.

  11. Microstimulation of primary afferent neurons in the L7 dorsal root ganglia using multielectrode arrays in anesthetized cats: thresholds and recruitment properties

    NASA Astrophysics Data System (ADS)

    Gaunt, R. A.; Hokanson, J. A.; Weber, D. J.

    2009-10-01

    Current research in motor neural prosthetics has focused primarily on issues related to the extraction of motor command signals from the brain (e.g. brain-machine interfaces) to direct the motion of prosthetic limbs. Patients using these types of systems could benefit from a somatosensory neural interface that conveys natural tactile and kinesthetic sensations for the prosthesis. Electrical microstimulation within the dorsal root ganglia (DRG) has been proposed as one method to accomplish this, yet little is known about the recruitment properties of electrical microstimulation in activating nerve fibers in this structure. Current-controlled microstimulation pulses in the range of 1-15 µA (200 µs, leading cathodic pulse) were delivered to the L7 DRG in four anesthetized cats using penetrating microelectrode arrays. Evoked responses and their corresponding conduction velocities (CVs) were measured in the sciatic nerve with a 5-pole nerve cuff electrode arranged as two adjacent tripoles. It was found that in 76% of the 69 electrodes tested, the stimulus threshold was less than or equal to 3 µA, with the lowest recorded threshold being 1.1 µA. The CVs of afferents recruited at threshold had a bimodal distribution with peaks at 70 m s-1 and 85 m s-1. In 53% of cases, the CV of the response at threshold was slower (i.e. smaller diameter fiber) than the CVs of responses observed at increasing stimulation amplitudes. In summary, we found that microstimulation applied through penetrating microelectrodes in the DRG provides selective recruitment of afferent fibers from a range of sensory modalities (as identified by CVs) at very low stimulation intensities. We conclude that the DRG may serve as an attractive location from which to introduce surrogate somatosensory feedback into the nervous system.

  12. VO2max and ventilatory threshold of trained cyclists are not affected by 28-day L-arginine supplementation.

    PubMed

    Sunderland, Kyle L; Greer, Felicia; Morales, Jacobo

    2011-03-01

    The ergogenic effect of L-arginine on an endurance-trained population is not well studied. The few studies that have investigated L-arginine on this population have not been conducted in a laboratory setting or measured aerobic variables. The purpose of the current study is to determine if 28 days of L-arginine supplementation in trained male cyclists affects VO2max and ventilatory threshold (VT). Eighteen (18) endurance-trained male cyclists (mean ± SD, age: 36.3 ± 7.9 years; height: 182.4 ± 4.6 cm; and body mass: 79.5 ± 4.7 kg) performed a graded exercise test (GXT; 50 W + 25 W·min) before and after 28 days of supplementation with L-arginine (ARG; 2 × 6 g·d) or placebo (PLA; cornstarch). The GXT was conducted on the subject's own bicycle using the RacerMate CompuTrainer (Seattle, WA, USA). VO2 was continuously recorded using the ParvoMedics TrueOne 2400 metabolic cart (Salt Lake City, UT, USA) and VT was established by plotting the ventilatory equivalent for O2 (VE/VO2) and the ventilatory equivalent for CO2 (VE/VCO2) and identifying the point at which VE/VO2 increases with no substantial changes in VE/VCO2. L-arginine supplementation had no effect from initial VO2max (PL, 58.7 ± 7.1 ml·kg·min; ARG, 63.5 ± 7.3 ml·kg·min) to postsupplement VO2max (PL, 58.9 ± 6.0 ml·kg·min; ARG, 63.2 ± 7.2 ml·kg·min). Also, no effect was seen from initial VT (PL, 75.7 ± 4.6% VO2max; ARG, 76.0 ± 5.3% VO2max) to postsupplement VT (PL, 74.3 ± 8.1% VO2max; ARG, 74.2 ± 6.4% VO2max). These results indicate that L-arginine does not impact VO2max or VT in trained male cyclists.

  13. H-, He-like recombination spectra - II. l-changing collisions for He Rydberg states

    NASA Astrophysics Data System (ADS)

    Guzmán, F.; Badnell, N. R.; Williams, R. J. R.; van Hoof, P. A. M.; Chatzikos, M.; Ferland, G. J.

    2017-01-01

    Cosmological models can be constrained by determining primordial abundances. Accurate predictions of the He I spectrum are needed to determine the primordial helium abundance to a precision of <1 per cent in order to constrain big bang nucleosynthesis models. Theoretical line emissivities at least this accurate are needed if this precision is to be achieved. In the first paper of this series, which focused on H I, we showed that differences in l-changing collisional rate coefficients predicted by three different theories can translate into 10 per cent changes in predictions for H I spectra. Here, we consider the more complicated case of He atoms, where low-l subshells are not energy degenerate. A criterion for deciding when the energy separation between l subshells is small enough to apply energy-degenerate collisional theories is given. Moreover, for certain conditions, the Bethe approximation originally proposed by Pengelly & Seaton is not sufficiently accurate. We introduce a simple modification of this theory which leads to rate coefficients which agree well with those obtained from pure quantal calculations using the approach of Vrinceanu et al. We show that the l-changing rate coefficients from the different theoretical approaches lead to differences of ˜10 per cent in He I emissivities in simulations of H II regions using spectral code CLOUDY.

  14. Relation of the runaway avalanche threshold to momentum space topology

    NASA Astrophysics Data System (ADS)

    McDevitt, Christopher J.; Guo, Zehua; Tang, Xian-Zhu

    2018-02-01

    The underlying physics responsible for the formation of an avalanche instability due to the generation of secondary electrons is studied. A careful examination of the momentum space topology of the runaway electron population is carried out with an eye toward identifying how qualitative changes in the momentum space of the runaway electrons is correlated with the avalanche threshold. It is found that the avalanche threshold is tied to the merger of an O and X point in the momentum space of the primary runaway electron population. Such a change of the momentum space topology is shown to be accurately described by a simple analytic model, thus providing a powerful means of determining the avalanche threshold for a range of model assumptions.

  15. Relation of the runaway avalanche threshold to momentum space topology

    DOE PAGES

    McDevitt, Christopher J.; Guo, Zehua; Tang, Xian -Zhu

    2018-01-05

    Here, the underlying physics responsible for the formation of an avalanche instability due to the generation of secondary electrons is studied. A careful examination of the momentum space topology of the runaway electron population is carried out with an eye toward identifying how qualitative changes in the momentum space of the runaway electrons is correlated with the avalanche threshold. It is found that the avalanche threshold is tied to the merger of an O and X point in the momentum space of the primary runaway electron population. Such a change of the momentum space topology is shown to be accuratelymore » described by a simple analytic model, thus providing a powerful means of determining the avalanche threshold for a range of model assumptions.« less

  16. Relation of the runaway avalanche threshold to momentum space topology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McDevitt, Christopher J.; Guo, Zehua; Tang, Xian -Zhu

    Here, the underlying physics responsible for the formation of an avalanche instability due to the generation of secondary electrons is studied. A careful examination of the momentum space topology of the runaway electron population is carried out with an eye toward identifying how qualitative changes in the momentum space of the runaway electrons is correlated with the avalanche threshold. It is found that the avalanche threshold is tied to the merger of an O and X point in the momentum space of the primary runaway electron population. Such a change of the momentum space topology is shown to be accuratelymore » described by a simple analytic model, thus providing a powerful means of determining the avalanche threshold for a range of model assumptions.« less

  17. The cali meteorite fell: A new H/L ordinary chondrite

    USGS Publications Warehouse

    Rodriguez, J.M.T.; Llorca, J.; Rubin, A.E.; Grossman, J.N.; Sears, D.W.G.; Naranjo, M.; Bretzius, S.; Tapia, M.; Sepulveda, M.H.G.

    2009-01-01

    The fall of the Cali meteorite took place on 6 July 2007 at 16 h 32 ?? 1 min local time (21 h 32 ?? 1 min UTC). A daylight fireball was witnessed by hundreds of people in the Cauca Valley in Colombia from which 10 meteorite samples with a total mass of 478 g were recovered near 3??24.3'N, 76??30.6'W. The fireball trajectory and radiant have been reconstructed with moderate accuracy. From the computed radiant and from considering various plausible velocities, we obtained a range of orbital solutions that suggest that the Cali progenitor meteoroid probably originated in the main asteroid belt. Based on petrography, mineral chemistry, magnetic susceptibility, fhermoluminescence, and bulk chemistry, the Cali meteorite is classified as an H/L4 ordinary chondrite breccia.

  18. A High Performance H2-Cl2 Fuel Cell for Space Power Applications

    NASA Technical Reports Server (NTRS)

    Anderson, Everett B.; Taylor, E. Jennings; Wilemski, Gerald; Gelb, Alan

    1993-01-01

    NASA has numerous airborne/spaceborne applications for which high power and energy density power sources are needed. The proton exchange membrane fuel cell (PEMFC) is an attractive candidate for such a power source. PEMFC's offer many advantages for airborne/spaceborne applications. They have high power and energy densities, convert fuel to electrical power with high efficiency at both part and full load, and can rapidly startup and shutdown. In addition, PEMFC's are lightweight and operate silently. A significant impediment to the attainment of very high power and energy densities by PEMFC's is their current exclusive reliance on oxygen as the oxidant. Conventional PEMFC's oxidize hydrogen at the anode and reduce oxygen at the cathode. The electrode kinetics of oxygen reduction are known to be highly irreversible, incurring large overpotential losses. In addition, the modest open circuit potential of 1.2V for the H2-O2 fuel cell is unattainable due to mixed potential effects at the oxygen electrode. Because of the high overpotential losses, cells using H2 and O2 are capable of achieving high current densities only at very low cell voltages, greatly curtailing their power output. Based on experimental work on chlorine reduction in a gas diffusion electrode, we believe significant increases in both the energy and power densities of PEMFC systems can be achieved by employing chlorine as an alternative oxidant.

  19. Alkaline pH activates the transport activity of GLUT1 in L929 fibroblast cells.

    PubMed

    Gunnink, Stephen M; Kerk, Samuel A; Kuiper, Benjamin D; Alabi, Ola D; Kuipers, David P; Praamsma, Riemer C; Wrobel, Kathryn E; Louters, Larry L

    2014-04-01

    The widely expressed mammalian glucose transporter, GLUT1, can be acutely activated in L929 fibroblast cells by a variety of conditions, including glucose deprivation, or treatment with various respiration inhibitors. Known thiol reactive compounds including phenylarsine oxide and nitroxyl are the fastest acting stimulators of glucose uptake, implicating cysteine biochemistry as critical to the acute activation of GLUT1. In this study, we report that in L929 cells glucose uptake increases 6-fold as the pH of the uptake solution is increased from 6 to 9 with the half-maximal activation at pH 7.5; consistent with the pKa of cysteine residues. This pH effect is essentially blocked by the pretreatment of the cells with either iodoacetamide or cinnamaldehyde, compounds that form covalent adducts with reduced cysteine residues. In addition, the activation by alkaline pH is not additive at pH 8 with known thiol reactive activators such as phenylarsine oxide or hydroxylamine. Kinetic analysis in L929 cells at pH 7 and 8 indicate that alkaline conditions both increases the Vmax and decreases the Km of transport. This is consistent with the observation that pH activation is additive to methylene blue, which activates uptake by increasing the Vmax, as well as to berberine, which activates uptake by decreasing the Km. This suggests that cysteine biochemistry is utilized in both methylene blue and berberine activation of glucose uptake. In contrast a pH increase from 7 to 8 in HCLE cells does not further activate glucose uptake. HCLE cells have a 25-fold higher basal glucose uptake rate than L929 cells and the lack of a pH effect suggests that the cysteine biochemistry has already occurred in HCLE cells. The data are consistent with pH having a complex mechanism of action, but one likely mediated by cysteine biochemistry. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  20. Determination of sensation threshold from small pulse trains of 2.01μm laser light

    NASA Astrophysics Data System (ADS)

    Dugan, Daniel C.; Johnson, Thomas E.

    2009-02-01

    The determination of sensation thresholds has applications ranging from uses in the medical community such as neural pathway mapping and for the diagnosis of diabetic neuropathy, to potential uses in determining safety standards. This study sought to determine the sensation threshold, and the distribution of sensation probabilities, for pulse trains ranging from two 10 ms pulses to nine 10 ms pulses from 2.01 μm laser light incident on a human forearm and chest. Threshold was defined as the energy density that would elicit sensation 50% of the time (ED50). A method of levels approach was used in conjunction with a monovariate binary response model to determine the ED50. We determined the ED50 and also a distribution of threshold probabilities. Threshold was found to be largely dependant on total energy deposited for smaller pulse trains, and thus independent of the number of pulses. Total energy becomes less important as the number of pulses increases however, and a decrease in threshold was measured for a nine pulse train as compared to one through four pulse trains. Thus we have demonstrated that this method is a useful and easy way for determining sensation thresholds from a 2.01 μm laser for possible clinical use. We have also demonstrated that lower power lasers when pulsed can elicit sensation at comparable levels to higher power single pulse lasers.

  1. 75 FR 3468 - Revised Jurisdictional Thresholds For Section 7A of the Clayton Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-21

    ... revised thresholds for the Hart-Scott-Rodino Antitrust Improvements Act of 1976 required by the 2000... Hart-Scott-Rodino Antitrust Improvements Act of 1976, Pub. L. 94-435, 90 Stat. 1390 (``the Act... product, in accordance with Section 8(a)(5). The new thresholds, which take effect 30 days after...

  2. Quasi-Two-Dimensional h-BN/β-Ga2O3 Heterostructure Metal-Insulator-Semiconductor Field-Effect Transistor.

    PubMed

    Kim, Janghyuk; Mastro, Michael A; Tadjer, Marko J; Kim, Jihyun

    2017-06-28

    β-gallium oxide (β-Ga 2 O 3 ) and hexagonal boron nitride (h-BN) heterostructure-based quasi-two-dimensional metal-insulator-semiconductor field-effect transistors (MISFETs) were demonstrated by integrating mechanical exfoliation of (quasi)-two-dimensional materials with a dry transfer process, wherein nanothin flakes of β-Ga 2 O 3 and h-BN were utilized as the channel and gate dielectric, respectively, of the MISFET. The h-BN dielectric, which has an extraordinarily flat and clean surface, provides a minimal density of charged impurities on the interface between β-Ga 2 O 3 and h-BN, resulting in superior device performances (maximum transconductance, on/off ratio, subthreshold swing, and threshold voltage) compared to those of the conventional back-gated configurations. Also, double-gating of the fabricated device was demonstrated by biasing both top and bottom gates, achieving the modulation of the threshold voltage. This heterostructured wide-band-gap nanodevice shows a new route toward stable and high-power nanoelectronic devices.

  3. Single Spin Asymmetries in l p(transv. pol.) --> h X processes and transverse momentum dependent factorization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anselmino, Mauro; Mariaelena, Boglione; D'Alesio, Umberto

    2014-06-01

    Some estimates for the transverse Single Spin Asymmetry, A_N, in the inclusive processes l p(transv. Pol.) --> h X, given in a previous paper, are expanded and compared with new experimental data. The predictions are based on the Sivers distributions and the Collins fragmentation functions which fit the azimuthal asymmetries measured in Semi-Inclusive Deep Inelastic Scattering (SIDIS) processes (l p(transv. Pol.) --> l' h X). The factorisation in terms of Transverse Momentum Dependent distribution and fragmentation functions (TMD factorisation) -- i.e., the theoretical framework in which SIDIS azimuthal asymmetries are analysed -- is assumed to hold also for the inclusivemore » process l p --> h X at large P_T. The values of A_N thus obtained agree in sign and shape with the data. Some predictions are given for future experiments.« less

  4. Mitochondrial dysfunction in H9c2 cells during ischemia and amelioration with Tribulus terrestris L.

    PubMed

    Reshma, P L; Sainu, Neethu S; Mathew, Anil K; Raghu, K G

    2016-05-01

    The present study investigates the protective effect of partially characterized Tribulus terrestris L. fruit methanol extract against mitochondrial dysfunction in cell based (H9c2) myocardial ischemia model. To induce ischemia, the cells were maintained in an ischemic buffer (composition in mM -137 NaCl, 12 KCl, 0.5 MgCl2, 0.9 CaCl2, 20 HEPES, 20 2-deoxy-d-glucose, pH-6.2) at 37°C with 0.1% O2, 5% CO2, and 95% N2 in a hypoxia incubator for 1h. Cells were pretreated with various concentrations of T. terrestris L. fruit methanol extract (10 and 25μg/ml) and Cyclosporin A (1μM) for 24h prior to the induction of ischemia. Different parameters like lactate dehydrogenase release, total antioxidant capacity, glutathione content and antioxidant enzymes were investigated. Studies were conducted on mitochondria by analyzing alterations in mitochondrial membrane potential, integrity, and dynamics (fission and fusion proteins - Mfn1, Mfn2, OPA1, Drp1 and Fis1). Various biochemical processes in mitochondria like activity of electron transport chain (ETC) complexes, oxygen consumption and ATP production was measured. Ischemia for 1h caused a significant (p≤0.05) increase in LDH leakage, decrease in antioxidant activity and caused mitochondrial dysfunction. T. terrestris L. fruit methanol extract pretreatment was found effective in safeguarding mitochondria via its antioxidant potential, mediated through various bioactives. HPLC of T. terrestris L. fruit methanol extract revealed the presence of ferulic acid, phloridzin and diosgenin. T. terrestris L. fruit ameliorate ischemic insult in H9c2 cells by safeguarding mitochondrial function. This validates the use of T. terrestris L. against heart disorders. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Hour-glass ceilings: Work-hour thresholds, gendered health inequities.

    PubMed

    Dinh, Huong; Strazdins, Lyndall; Welsh, Jennifer

    2017-03-01

    Long workhours erode health, which the setting of maximum weekly hours aims to avert. This 48-h limit, and the evidence base to support it, has evolved from a workforce that was largely male, whose time in the labour force was enabled by women's domestic work and care giving. The gender composition of the workforce has now changed, and many women (as well as some men) combine care-giving with paid work, a change viewed as fundamental for gender equality. However, it raises questions on the suitability of the work time limit and the extent it is protective of health. We estimate workhour-mental health thresholds, testing if they vary for men and women due to gendered workloads and constraints on and off the job. Using six waves of data from a nationally representative sample of Australian adults (24-65 years), surveyed in the Household Income Labour Dynamics of Australia Survey (N = 3828 men; 4062 women), our study uses a longitudinal, simultaneous equation approach to address endogeneity. Averaging over the sample, we find an overall threshold of 39 h per week beyond which mental health declines. Separate curves then estimate thresholds for men and women, by high or low care and domestic time constraints, using stratified and pooled samples. We find gendered workhour-health limits (43.5 for men, 38 for women) which widen further once differences in resources on and off the job are considered. Only when time is 'unencumbered' and similar time constraints and contexts are assumed, do gender gaps narrow and thresholds approximate the 48-h limit. Our study reveals limits to contemporary workhour regulation which may be systematically disadvantaging women's health. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Hydrogen peroxide preferentially activates capsaicin-sensitive high threshold afferents via TRPA1 channels in the guinea pig bladder.

    PubMed

    Nicholas, S; Yuan, S Y; Brookes, S J H; Spencer, N J; Zagorodnyuk, V P

    2017-01-01

    There is increasing evidence suggesting that ROS play a major pathological role in bladder dysfunction induced by bladder inflammation and/or obstruction. The aim of this study was to determine the effect of H 2 O 2 on different types of bladder afferents and its mechanism of action on sensory neurons in the guinea pig bladder. 'Close-to-target' single unit extracellular recordings were made from fine branches of pelvic nerves entering the guinea pig bladder, in flat sheet preparations, in vitro. H 2 O 2 (300-1000 μM) preferentially and potently activated capsaicin-sensitive high threshold afferents but not low threshold stretch-sensitive afferents, which were only activated by significantly higher concentrations of hydrogen peroxide. The TRPV1 channel agonist, capsaicin, excited 86% of high threshold afferents. The TRPA1 channel agonist, allyl isothiocyanate and the TRPM8 channel agonist, icilin activated 72% and 47% of capsaicin-sensitive high threshold afferents respectively. The TRPA1 channel antagonist, HC-030031, but not the TRPV1 channel antagonist, capsazepine or the TRPM8 channel antagonist, N-(2-aminoethyl)-N-[[3-methoxy-4-(phenylmethoxy)phenyl]methyl]thiophene-2-carboxamide, significantly inhibited the H 2 O 2 -induced activation of high threshold afferents. Dimethylthiourea and deferoxamine did not significantly change the effect of H 2 O 2 on high threshold afferents. The findings show that H 2 O 2 , in the concentration range detected in inflammation or reperfusion after ischaemia, evoked long-lasting activation of the majority of capsaicin-sensitive high threshold afferents, but not low threshold stretch-sensitive afferents. The data suggest that the TRPA1 channels located on these capsaicin-sensitive afferent fibres are probable targets of ROS released during oxidative stress. © 2016 The British Pharmacological Society.

  7. Hydrogen peroxide preferentially activates capsaicin‐sensitive high threshold afferents via TRPA1 channels in the guinea pig bladder

    PubMed Central

    Nicholas, S; Yuan, S Y; Brookes, S J H; Spencer, N J

    2016-01-01

    Background and Purpose There is increasing evidence suggesting that ROS play a major pathological role in bladder dysfunction induced by bladder inflammation and/or obstruction. The aim of this study was to determine the effect of H2O2 on different types of bladder afferents and its mechanism of action on sensory neurons in the guinea pig bladder. Experimental Approach ‘Close‐to‐target’ single unit extracellular recordings were made from fine branches of pelvic nerves entering the guinea pig bladder, in flat sheet preparations, in vitro. Key Results H2O2 (300–1000 μM) preferentially and potently activated capsaicin‐sensitive high threshold afferents but not low threshold stretch‐sensitive afferents, which were only activated by significantly higher concentrations of hydrogen peroxide. The TRPV1 channel agonist, capsaicin, excited 86% of high threshold afferents. The TRPA1 channel agonist, allyl isothiocyanate and the TRPM8 channel agonist, icilin activated 72% and 47% of capsaicin‐sensitive high threshold afferents respectively. The TRPA1 channel antagonist, HC‐030031, but not the TRPV1 channel antagonist, capsazepine or the TRPM8 channel antagonist, N‐(2‐aminoethyl)‐N‐[[3‐methoxy‐4‐(phenylmethoxy)phenyl]methyl]thiophene‐2‐carboxamide, significantly inhibited the H2O2‐induced activation of high threshold afferents. Dimethylthiourea and deferoxamine did not significantly change the effect of H2O2 on high threshold afferents. Conclusions and Implications The findings show that H2O2, in the concentration range detected in inflammation or reperfusion after ischaemia, evoked long‐lasting activation of the majority of capsaicin‐sensitive high threshold afferents, but not low threshold stretch‐sensitive afferents. The data suggest that the TRPA1 channels located on these capsaicin‐sensitive afferent fibres are probable targets of ROS released during oxidative stress. PMID:27792844

  8. 33. A.C. PANEL FOR MENTONE POWER HOUSE, P.L. & P. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    33. A.C. PANEL FOR MENTONE POWER HOUSE, P.L. & P. CO., LOS ANGELES. RETRACED FROM MASSON'S DRAWING NO. C-275. JAN. 20, 1909. SCE drawing no. 52880. - Santa Ana River Hydroelectric System, SAR-3 Powerhouse, San Bernardino National Forest, Redlands, San Bernardino County, CA

  9. Liquid lithium loop system to solve challenging technology issues for fusion power plant

    DOE PAGES

    Ono, Masayuki; Majeski, Richard P.; Jaworski, Michael A.; ...

    2017-07-12

    Here, steady-state fusion power plant designs present major divertor technology challenges, including high divertor heat flux both in steady-state and during transients. In addition to these concerns, there are the unresolved technology issues of long term dust accumulation and associated tritium inventory and safety issues. It has been suggested that radiation-based liquid lithium (LL) divertor concepts with a modest lithium-loop could provide a possible solution for these outstanding fusion reactor technology issues, while potentially improving reactor plasma performance. The application of lithium (Li) in NSTX resulted in improved H-mode confinement, H-mode power threshold reduction, and reduction in the divertor peakmore » heat flux while maintaining essentially Li-free core plasma operation even during H-modes. These promising results in NSTX and related modeling calculations motivated the radiative liquid lithium divertor (RLLD) concept and its variant, the active liquid lithium divertor concept (ARLLD), taking advantage of the enhanced or non-coronal Li radiation in relatively poorly confined divertor plasmas. To maintain the LL purity in a 1 GW-electric class fusion power plant, a closed LL loop system with a modest circulating capacity of ~ 1 liter/second (l/sec) is envisioned. We examined two key technology issues: 1) dust or solid particle removal and 2) real time recovery of tritium from LL while keeping the tritium inventory level to an acceptable level. By running the LL-loop continuously, it can carry the dust particles and impurities generated in the vacuum vessel to the outside where the dust / impurities can be removed by relatively simple dust filter, cold trap and/or centrifugal separation systems. With ~ 1 l/sec LL flow, even a small 0.1% dust content by weight (or 0.5 g per sec) suggests that the LL-loop could carry away nearly 16 tons of dust per year. In a 1 GW-electric (or ~ 3 GW fusion power) fusion power plant, about 0.5 g / sec of

  10. Liquid lithium loop system to solve challenging technology issues for fusion power plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ono, Masayuki; Majeski, Richard P.; Jaworski, Michael A.

    Here, steady-state fusion power plant designs present major divertor technology challenges, including high divertor heat flux both in steady-state and during transients. In addition to these concerns, there are the unresolved technology issues of long term dust accumulation and associated tritium inventory and safety issues. It has been suggested that radiation-based liquid lithium (LL) divertor concepts with a modest lithium-loop could provide a possible solution for these outstanding fusion reactor technology issues, while potentially improving reactor plasma performance. The application of lithium (Li) in NSTX resulted in improved H-mode confinement, H-mode power threshold reduction, and reduction in the divertor peakmore » heat flux while maintaining essentially Li-free core plasma operation even during H-modes. These promising results in NSTX and related modeling calculations motivated the radiative liquid lithium divertor (RLLD) concept and its variant, the active liquid lithium divertor concept (ARLLD), taking advantage of the enhanced or non-coronal Li radiation in relatively poorly confined divertor plasmas. To maintain the LL purity in a 1 GW-electric class fusion power plant, a closed LL loop system with a modest circulating capacity of ~ 1 liter/second (l/sec) is envisioned. We examined two key technology issues: 1) dust or solid particle removal and 2) real time recovery of tritium from LL while keeping the tritium inventory level to an acceptable level. By running the LL-loop continuously, it can carry the dust particles and impurities generated in the vacuum vessel to the outside where the dust / impurities can be removed by relatively simple dust filter, cold trap and/or centrifugal separation systems. With ~ 1 l/sec LL flow, even a small 0.1% dust content by weight (or 0.5 g per sec) suggests that the LL-loop could carry away nearly 16 tons of dust per year. In a 1 GW-electric (or ~ 3 GW fusion power) fusion power plant, about 0.5 g / sec of

  11. Cost-Savings Analysis of Renal Scintigraphy, Stratified by Renal Function Thresholds: Mercaptoacetyltriglycine Versus Diethylene Triamine Penta-Acetic Acid.

    PubMed

    Parikh, Kushal R; Davenport, Matthew S; Viglianti, Benjamin L; Hubers, David; Brown, Richard K J

    2016-07-01

    To determine the financial implications of switching technetium (Tc)-99m mercaptoacetyltriglycine (MAG-3) to Tc-99m diethylene triamine penta-acetic acid (DTPA) at certain renal function thresholds before renal scintigraphy. Institutional review board approval was obtained, and informed consent was waived for this HIPAA-compliant, retrospective, cohort study. Consecutive adult subjects (27 inpatients; 124 outpatients) who underwent MAG-3 renal scintigraphy, in the period from July 1, 2012 to June 30, 2013, were stratified retrospectively by hypothetical serum creatinine and estimated glomerular filtration rate (eGFR) thresholds, based on pre-procedure renal function. Thresholds were used to estimate the financial effects of using MAG-3 when renal function was at or worse than a given cutoff value, and DTPA otherwise. Cost analysis was performed with consideration of raw material and preparation costs, with radiotracer costs estimated by both vendor list pricing and proprietary institutional pricing. The primary outcome was a comparison of each hypothetical threshold to the clinical reality in which all subjects received MAG-3, and the results were supported by univariate sensitivity analysis. Annual cost savings by serum creatinine threshold were as follows (threshold given in mg/dL): $17,319 if ≥1.0; $33,015 if ≥1.5; and $35,180 if ≥2.0. Annual cost savings by eGFR threshold were as follows (threshold given in mL/min/1.73 m(2)): $21,649 if ≤60; $28,414 if ≤45; and $32,744 if ≤30. Cost-savings inflection points were approximately 1.25 mg/dL (serum creatinine) and 60 mL/min/1.73m(2) (eGFR). Secondary analysis by proprietary institutional pricing revealed similar trends, and cost savings of similar magnitude. Sensitivity analysis confirmed cost savings at all tested thresholds. Reserving MAG-3 utilization for patients who have impaired renal function can impart substantial annual cost savings to a radiology department. Copyright © 2016 American College

  12. L-H transitions driven by ion heating in scrape-off layer turbulence (SOLT) model simulations

    NASA Astrophysics Data System (ADS)

    Russell, D. A.; D'Ippolito, D. A.; Myra, J. R.

    2015-11-01

    The original SOLT model now includes the evolution of ion pressure consistent with drift-ordering. It is a two-dimensional, electrostatic reduced model wherein closure relations, obtained by integrating the equations along the B-field, model parallel physics that includes sheath-mediated current and heat flux in the scrape-off-layer and electron drift waves inside the separatrix. Low (L) and high (H) confinement regimes are observed in SOLT simulations, depending on the strength of an ion pressure (i.e., ion heating) source localized inside the separatrix: With increasing heating, particle and energy confinement times at first decrease in the L-mode then rise in the H-mode. The L-H transition is marked by distinct changes in sheared-flow profiles. The addition of ion pressure dynamics enables modeling the self-consistent interaction between the ion diamagnetic drift and the radial electric field (mean and zonal flows). The roles of these sheared flows in mediating the L-H transition are explored. A new diagnostic, based on the density correlation function, is applied to study blob velocities in different regimes. Work supported by the U.S. Department of Energy Office of Science, Office of Fusion Energy Sciences, under Award Number DE-FG02-97ER54392.

  13. Ultralow-threshold Yb(3+):SiO(2) glass laser fabricated by the solgel process.

    PubMed

    Ostby, Eric P; Yang, Lan; Vahala, Kerry J

    2007-09-15

    A Yb-doped silica microcavity laser on a silicon chip is fabricated from a solgel thin film. The high-Q micro-toroid cavity, which has a finesse of 10,000, is evanescently coupled to an optical fiber taper. We report a threshold of 1.8 microW absorbed power that is, to the best of our knowledge, the lowest published threshold to date for any Yb-doped laser. The effect of Yb(3+) concentration on laser threshold is experimentally quantified.

  14. Global two-fluid turbulence simulations of L-H transitions and edge localized mode dynamics in the COMPASS-D tokamak

    NASA Astrophysics Data System (ADS)

    Thyagaraja, A.; Valovič, M.; Knight, P. J.

    2010-04-01

    It is shown that the transition from L-mode to H-mode regimes in tokamaks can be reproduced using a two-fluid, fully electromagnetic, plasma model when a suitable particle sink is added at the edge. Such a model is implemented in the CUTIE code [A. Thyagaraja et al., Eur. J. Mech. B/Fluids 23, 475 (2004)] and is illustrated on plasma parameters that mimic those in the COMPASS-D tokamak with electron cyclotron resonance heating [Fielding et al., Plasma Phys. Contr. Fusion 42, A191 (2000)]. In particular, it is shown that holding the heating power, current, and magnetic field constant and increasing the fuelling rate to raise the plasma density leads spontaneously to the formation of an edge transport barrier (ETB) which occurs going from low to higher density experimentally. In the following quiescent period in which the stored energy of the plasma rises linearly with time, a dynamical transition occurs in the simulation with the appearance of features resembling strong edge localized modes. The simulation qualitatively reproduces many features observed in the experiment. Its relative robustness suggests that some, at least of the observed characteristics of ETBs and L-H transitions, can be captured in the global electromagnetic turbulence model.

  15. CARA Risk Assessment Thresholds

    NASA Technical Reports Server (NTRS)

    Hejduk, M. D.

    2016-01-01

    Warning remediation threshold (Red threshold): Pc level at which warnings are issued, and active remediation considered and usually executed. Analysis threshold (Green to Yellow threshold): Pc level at which analysis of event is indicated, including seeking additional information if warranted. Post-remediation threshold: Pc level to which remediation maneuvers are sized in order to achieve event remediation and obviate any need for immediate follow-up maneuvers. Maneuver screening threshold: Pc compliance level for routine maneuver screenings (more demanding than regular Red threshold due to additional maneuver uncertainty).

  16. Nonlinear threshold effect in the Z-scan method of characterizing limiters for high-intensity laser light

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tereshchenko, S. A., E-mail: tsa@miee.ru; Savelyev, M. S.; Podgaetsky, V. M.

    A threshold model is described which permits one to determine the properties of limiters for high-powered laser light. It takes into account the threshold characteristics of the nonlinear optical interaction between the laser beam and the limiter working material. The traditional non-threshold model is a particular case of the threshold model when the limiting threshold is zero. The nonlinear characteristics of carbon nanotubes in liquid and solid media are obtained from experimental Z-scan data. Specifically, the nonlinear threshold effect was observed for aqueous dispersions of nanotubes, but not for nanotubes in solid polymethylmethacrylate. The threshold model fits the experimental Z-scanmore » data better than the non-threshold model. Output characteristics were obtained that integrally describe the nonlinear properties of the optical limiters.« less

  17. An adaptive design for updating the threshold value of a continuous biomarker

    PubMed Central

    Spencer, Amy V.; Harbron, Chris; Mander, Adrian; Wason, James; Peers, Ian

    2017-01-01

    Potential predictive biomarkers are often measured on a continuous scale, but in practice, a threshold value to divide the patient population into biomarker ‘positive’ and ‘negative’ is desirable. Early phase clinical trials are increasingly using biomarkers for patient selection, but at this stage, it is likely that little will be known about the relationship between the biomarker and the treatment outcome. We describe a single-arm trial design with adaptive enrichment, which can increase power to demonstrate efficacy within a patient subpopulation, the parameters of which are also estimated. Our design enables us to learn about the biomarker and optimally adjust the threshold during the study, using a combination of generalised linear modelling and Bayesian prediction. At the final analysis, a binomial exact test is carried out, allowing the hypothesis that ‘no population subset exists in which the novel treatment has a desirable response rate’ to be tested. Through extensive simulations, we are able to show increased power over fixed threshold methods in many situations without increasing the type-I error rate. We also show that estimates of the threshold, which defines the population subset, are unbiased and often more precise than those from fixed threshold studies. We provide an example of the method applied (retrospectively) to publically available data from a study of the use of tamoxifen after mastectomy by the German Breast Study Group, where progesterone receptor is the biomarker of interest. PMID:27417407

  18. Transient VEP and psychophysical chromatic contrast thresholds in children and adults.

    PubMed

    Boon, Mei Ying; Suttle, Catherine M; Dain, Stephen J

    2007-07-01

    It has been found that humans are able to distinguish colours without luminance cues by about 2-4 months of age and that sensitivity to colour difference develops during childhood, reaching a peak around adolescence. This prolonged period of maturation is reflected by improvements in psychophysical threshold measures and by the VEP characteristics of morphology, latency and amplitude. An intra-individual comparison of VEP and psychophysical responses to isoluminant colour stimuli has not been made in children, however, and this was the aim of the present study. VEPs were recorded from 49 subjects, children (age range: 4.8-12.6 years) and adults (age range: 25.7-33.2 years). Psychophysical and VEP thresholds were both measured in 40 of those subjects. Nominally isoluminant chromatic (L-M) sinewave gratings were presented in onset-offset mode and identical stimuli were used for psychophysical and VEP recordings to allow comparison. In agreement with previous reports, morphology of the transient VEP in response to this stimulus differed considerably between children and adults. There was a significant difference between psychophysical and VEP thresholds in children, but not in adults. Our findings support and expand on previous work on maturation of the L-M chromatic pathway and indicate a larger discrepancy between VEP and psychophysical chromatic thresholds in children than in adults.

  19. Modelling redshift space distortion in the post-reionization H I 21-cm power spectrum

    NASA Astrophysics Data System (ADS)

    Sarkar, Debanjan; Bharadwaj, Somnath

    2018-05-01

    The post-reionization H I 21-cm signal is an excellent candidate for precision cosmology, this however requires accurate modelling of the expected signal. Sarkar et al. have simulated the real space H I 21-cm signal and have modelled the H I power spectrum as P_{{H I}}(k)=b^2 P(k), where P(k) is the dark matter power spectrum and b(k) is a (possibly complex) scale-dependent bias for which fitting formulas have been provided. This paper extends these simulations to incorporate redshift space distortion and predicts the expected redshift space H I 21-cm power spectrum P^s_{{H I}}(k_{\\perp },k_{allel }) using two different prescriptions for the H I distributions and peculiar velocities. We model P^s_{{H I}}(k_{\\perp },k_{allel }), assuming that it is the product of P_{{H I}}(k)=b^2 P(k) with a Kaiser enhancement term and a Finger of God (FoG) damping which has σp the pair velocity dispersion as a free parameter. Considering several possibilities for the bias and the damping profile, we find that the models with a scale-dependent bias and a Lorentzian damping profile best fit the simulated P^s_{{H I}}(k_{\\perp },k_{allel }) over the entire range 1 ≤ z ≤ 6. The best-fitting value of σp falls approximately as (1 + z)-m with m = 2 and 1.2, respectively, for the two different prescriptions. The model predictions are consistent with the simulations for k < 0.3 Mpc-1 over the entire z range for the monopole P^s_0(k), and at z ≤ 3 for the quadrupole P^s_2(k). At z ≥ 4 the models underpredict P^s_2(k) at large k, and the fit is restricted to k < 0.15 Mpc-1.

  20. Threshold foraging behavior of baleen whales

    USGS Publications Warehouse

    Piatt, John F.; Methven, David A.

    1992-01-01

    We conducted hydroacoustic surveys for capelin Mallotus villosus in Witless Bay, Newfoundland, Canada, on 61 days during the summers of 1983 to 1985. On 32 of those days in whlch capelin surveys were conducted, we observed a total of 129 baleen whales - Including 93 humpback Megaptera novaeangliae, 31 minke Balaenoptera acutorostrata and 5 fin whales B. phvsalus. Although a few whales were observed when capelin schools were scarce, the majority (96%) of whales were observed when mean daily capelin densities exceeded 5 schools per linear km surveyed (range of means over 3 yr: 0.0 to 14.0 schools km-1). Plots of daily whale abundance (no. h-1 surveyed) vs daily capelin school density (mean no. schools km-1 surveyed) in each summer revealed that baleen whales have a threshold foraging response to capelin density. Thresholds were estimated using a simple itterative step-function model. Foraging thresholds of baleen whales (7.3, 5.0, and 5.8 schools km-1) varied between years in relation to the overall abundance of capelin schools in the study area during summer (means of 7.2, 3.3, and 5.3 schools km-1, respectively).

  1. Irreducible normalizer operators and thresholds for degenerate quantum codes with sublinear distances

    NASA Astrophysics Data System (ADS)

    Pryadko, Leonid P.; Dumer, Ilya; Kovalev, Alexey A.

    2015-03-01

    We construct a lower (existence) bound for the threshold of scalable quantum computation which is applicable to all stabilizer codes, including degenerate quantum codes with sublinear distance scaling. The threshold is based on enumerating irreducible operators in the normalizer of the code, i.e., those that cannot be decomposed into a product of two such operators with non-overlapping support. For quantum LDPC codes with logarithmic or power-law distances, we get threshold values which are parametrically better than the existing analytical bound based on percolation. The new bound also gives a finite threshold when applied to other families of degenerate quantum codes, e.g., the concatenated codes. This research was supported in part by the NSF Grant PHY-1416578 and by the ARO Grant W911NF-11-1-0027.

  2. Impact of reducing the threshold for acetylcysteine treatment in acute paracetamol poisoning: the recent United Kingdom experience.

    PubMed

    Bateman, D N; Dear, J W; Carroll, R; Pettie, J; Yamamoto, T; Elamin, M E M O; Peart, L; Dow, M; Coyle, J; Gray, A; Dargan, P I; Wood, D M; Eddleston, M; Thomas, S H L

    2014-01-01

    On 3 September 2012, the licensed indication for acetylcysteine was changed in the United Kingdom (UK) so that all patients with a plasma paracetamol concentration above a "100 mg/L" (4 h post ingestion) nomogram treatment line after an acute paracetamol (acetaminophen) overdose should be treated. This is a lower threshold than that used in the United States, Canada, Australia, and New Zealand. Here we report the impact of this change in the UK on the management of patients with acute overdose in different paracetamol concentration ranges. This is a cohort study, consisting of a retrospective analysis conducted on prospectively collected audit data in three UK hospitals. Following appropriate ethical and data protection authority approval, data for patients presenting within 24 h of an acute timed single paracetamol overdose were extracted. Numbers of admissions and use of antidote in relation to different paracetamol concentration bands (< 100 mg/L; 100-149 mg/L; 150-199 mg/L; and ≥ 200 mg/L at 4 h) were analyzed for one-year periods before and after the change. Comparing the year before with the year after the change, there was no change in the numbers of patients presenting to hospital within 24 h of acute timed paracetamol overdose (1246 before and 1251 after), but more patients were admitted (759 before and 849 after) and treated with acetylcysteine (389 before and 539 after). Of the 150 additional patients treated with acetylcysteine in the year following the change, 114 (76%, 95% CI: 68.4-82.6) were in the 100-149 group and 9 (6.0%, 95% CI: 2.8-11.1) in the 150-199 group. Changes to national guidelines for managing paracetamol poisoning in the UK have increased the numbers of patients with acute overdose treated with acetylcysteine, with most additional treatments occurring in patients in the 100-149 mg/L dose range, a group at low risk of hepatotoxicity and higher risk of adverse reactions.

  3. [Enhanced ε-poly-L-lysine production through pH regulation and organic nitrogen addition in fed-batch fermentation].

    PubMed

    Sun, Qixing; Chen, Xusheng; Ren, Xidong; Zheng, Gencheng; Mao, Zhonggui

    2015-05-01

    During the production of ε-poly-L-lysine (ε-PL) in fed-batch fermentation, the decline of ε-PL synthesis often occurs at middle or late phase of the fermentation. To solve the problem, we adopted two strategies, namely pH shift and feeding yeast extract, to improve the productivity of ε-PL. ε-PL productivity in fermentation by pH shift and feeding yeast extract achieved 4.62 g/(L x d) and 5.16 g/(L x d), which were increased by 27.3% and 42.2% compared with the control ε-PL fed-batch fermentation, respectively. Meanwhile, ε-PL production enhanced 36.95 g/L and 41.32 g/L in 192 h with these two strategies, increased by 27.4% and 42.48% compared to the control, respectively. ε-PL production could be improved at middle or late phase of fed-batch fermentation by pH shift or feeding yeast extract.

  4. New findings on phosphodiesterases, MoPdeH and MoPdeL, in Magnaporthe oryzae revealed by structural analysis.

    PubMed

    Yang, Li-Na; Yin, Ziyi; Zhang, Xi; Feng, Wanzhen; Xiao, Yuhan; Zhang, Haifeng; Zheng, Xiaobo; Zhang, Zhengguang

    2018-05-01

    The cyclic adenosine monophosphate (cAMP) signalling pathway mediates signal communication and sensing during infection-related morphogenesis in eukaryotes. Many studies have implicated cAMP as a critical mediator of appressorium development in the rice blast fungus, Magnaporthe oryzae. The cAMP phosphodiesterases, MoPdeH and MoPdeL, as key regulators of intracellular cAMP levels, play pleiotropic roles in cell wall integrity, cellular morphology, appressorium formation and infectious growth in M. oryzae. Here, we analysed the roles of domains of MoPdeH and MoPdeL separately or in chimeras. The results indicated that the HD and EAL domains of MoPdeH are indispensable for its phosphodiesterase activity and function. Replacement of the MoPdeH HD domain with the L1 and L2 domains of MoPdeL, either singly or together, resulted in decreased cAMP hydrolysis activity of MoPdeH. All of the transformants exhibited phenotypes similar to that of the ΔMopdeH mutant, but also revealed that EAL and L1 play additional roles in conidiation, and that L1 is involved in infectious growth. We further found that the intracellular cAMP level is important for surface signal recognition and hyphal autolysis. The intracellular cAMP level negatively regulates Mps1-MAPK and positively regulates Pmk1-MAPK in the rice blast fungus. Our results provide new information to better understand the cAMP signalling pathway in the development, differentiation and plant infection of the fungus. © 2017 BSPP AND JOHN WILEY & SONS LTD.

  5. Carbon deposition thresholds on nickel-based solid oxide fuel cell anodes I. Fuel utilization

    NASA Astrophysics Data System (ADS)

    Kuhn, J.; Kesler, O.

    2015-03-01

    In the first of a two part publication, the effect of fuel utilization (Uf) on carbon deposition rates in solid oxide fuel cell nickel-based anodes was studied. Representative 5-component CH4 reformate compositions (CH4, H2, CO, H2O, & CO2) were selected graphically by plotting the solutions to a system of mass-balance constraint equations. The centroid of the solution space was chosen to represent a typical anode gas mixture for each nominal Uf value. Selected 5-component and 3-component gas mixtures were then delivered to anode-supported cells for 10 h, followed by determination of the resulting deposited carbon mass. The empirical carbon deposition thresholds were affected by atomic carbon (C), hydrogen (H), and oxygen (O) fractions of the delivered gas mixtures and temperature. It was also found that CH4-rich gas mixtures caused irreversible damage, whereas atomically equivalent CO-rich compositions did not. The coking threshold predicted by thermodynamic equilibrium calculations employing graphite for the solid carbon phase agreed well with empirical thresholds at 700 °C (Uf ≈ 32%); however, at 600 °C, poor agreement was observed with the empirical threshold of ∼36%. Finally, cell operating temperatures correlated well with the difference in enthalpy between the supplied anode gas mixtures and their resulting thermodynamic equilibrium gas mixtures.

  6. The Electromyographic Threshold in Girls and Women.

    PubMed

    Long, Devon; Dotan, Raffy; Pitt, Brynlynn; McKinlay, Brandon; O'Brien, Thomas D; Tokuno, Craig; Falk, Bareket

    2017-02-01

    The electromyographic threshold (EMG Th ) is thought to reflect increased high-threshold/type-II motor-unit (MU) recruitment and was shown higher in boys than in men. Women differ from men in muscular function. Establish whether females' EMG Th and girls-women differences are different than males'. Nineteen women (22.9 ± 3.3yrs) and 20 girls (10.3 ± 1.1yrs) had surface EMG recorded from the right and left vastus lateralis muscles during ramped cycle-ergometry to exhaustion. EMG root-mean-squares were averaged per pedal revolution. EMG Th was determined as the least residual sum of squares for any two regression-line data divisions, if the trace rose ≥ 3SD above its regression line. EMG Th was expressed as % final power-output (%Pmax) and %VO 2 pk power (%P VO2pk ). EMG Th was detected in 13 (68%) of women, but only 9 (45%) of girls (p < .005) and tended to be higher in the girls (%Pmax= 88.6 ± 7.0 vs. 83.0 ± 6.9%, p = .080; %P VO2pk = (101.6 ± 17.6 vs. 90.6 ± 7.8%, p = .063). When EMG Th was undetected it was assumed to occur at 100%Pmax or beyond. Consequently, EMG Th values turned significantly higher in girls than in women (94.8 ± 7.4 vs. 88.4 ± 9.9%Pmax, p = .026; and 103.2 ± 11.7 vs. 95.2 ± 9.9%P VO2pk , p = .028). During progressive exercise, girls appear to rely less on higher-threshold/type-II MUs than do women, suggesting differential muscle activation strategy.

  7. Co-administration of recombinant major envelope proteins (rA27L and rH3L) of buffalopox virus provides enhanced immunogenicity and protective efficacy in animal models.

    PubMed

    Kumar, Amit; Yogisharadhya, Revanaiah; Venkatesan, Gnanavel; Bhanuprakash, Veerakyathappa; Pandey, Awadh Bihari; Shivachandra, Sathish Bhadravati

    2017-05-01

    Buffalopox virus (BPXV) and other vaccinia-like viruses (VLVs) are causing an emerging/re-emerging zoonosis affecting buffaloes, cattle and humans in India and other countries. A27L and H3L are immuno-dominant major envelope proteins of intracellular mature virion (IMV) of orthopoxviruses (OPVs) and are highly conserved with an ability to elicit neutralizing antibodies. In the present study, two recombinant proteins namely; rA27L ( 21 S to E 110 ; ∼30 kDa) and rH3L( 1 M to I 280 ; ∼50 kDa) of BPXV-Vij/96 produced from Escherichia coli were used in vaccine formulation. A combined recombinant subunit vaccine comprising rA27L and rH3L antigens (10 μg of each) was used for active immunization of adult mice (20μg/dose/mice) with or without adjuvant (FCA/FIA) by intramuscular route. Immune responses revealed a gradual increase in antigen specific serum IgG as well as neutralizing antibody titers measured by using indirect-ELISA and serum neutralization test (SNT) respectively, which were higher as compared to that elicited by individual antigens. Suckling mice passively administered with combined anti-A27L and anti-H3L sera showed a complete (100%) pre-exposure protection upon challenge with virulent BPXV. Conclusively, this study highlights the potential utility of rA27L and rH3L proteins as safer candidate prophylactic antigens in combined recombinant subunit vaccine for buffalopox as well as passive protective efficacy of combined sera in employing better pre-exposure protection against virulent BPXV. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Threshold Dynamics of a Semiconductor Single Atom Maser

    NASA Astrophysics Data System (ADS)

    Liu, Yinyu

    Photon emission from single emitters provides fundamental insight into the detailed interaction between light and matter. Here we demonstrate a semiconductor single atom maser (SeSAM) that consists of a single InAs double quantum dot (DQD) that is coupled to a high quality factor microwave cavity. A finite bias results in population inversion in the DQD, enabling sizable cavity gain and stimulated emission. We develop a pulsed-gate approach that allows the SeSAM to be tuned across the masing threshold. The cavity output power as a function of DQD current is in good agreement with single atom maser theory once a small correction for lead emission is included. Photon statistics measurements show that the second-order correlation function of intra-cavity photon number, nc, crosses over from 〈nc2 〉 /〈nc 〉 2 = 2.1 below threshold to 〈nc2 〉 /〈nc 〉 2 = 1.2 above threshold. Large fluctuations are observed at threshold. In collaboration with J. Stehlik, C. Eichler, X. Mi, T. R. Hartke, M. J. Gullans, J. M. Taylor and J. R. Petta. Supported by the NSF and the Gordon and Betty Moore Foundation's EPiQS initiative through Grant No. GBMF4535.

  9. H-11-linked gene has a parallel effect on Leishmania major and L. donovani infections in mice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blackwell, J.M.; Hale, C.; Roberts, M.B.

    1985-01-01

    The courses of visceral infection following intravenous injection of Leishmania donovani amastigotes, or lesion growth following subcutaneous injection of L. major promastigotes, were examined in B10.129(10M) (H-2b, H-11b) mice and compared with disease profiles observed in congenic C57BL/10ScSn(= B10) (H-2b, H-11a) and B10.D2/n (H-2d, H-11a) mice, and in BALB/mice. Possession of alternative alleles at H-11 and closely linked loci transformed the normal curing/healing phenotype of B10 mice into a characteristically different noncuring/nonhealing phenotype affecting both visceral and subcutaneous infections in B10.129(10M) mice. In reciprocal radiation bone marrow chimeras made between the congenic B10 and B10.129(10M) strains, both cure and noncuremore » phenotypes were transferable with the donor hematopoietic system. Although it was possible to demonstrate transfer of suppression with T-enriched spleen cells from day 61 L. donovani-infected B10.129(10M) donor mice into 550 rad syngeneic recipients, the pretreatment of mice with sublethal irradiation did not, as in the earlier studies of Scl-controlled L. major nonhealing or H-2-controlled L. donovani noncure phenotypes, have a clear or consistent prophylactic effect. Together with the progressive disease profile observed even for L. donovani at low parasite doses this suggests that, despite their ability to develop initial delayed-type hypersensitivity reactions to parasite antigen early in L. major infection, B10.129(10M) mice possess some inherent defect in ability to mount a cell-mediated response effective at the level of macrophage neishmanial activity in vivo even when suppressor T cells are not generated. Elucidation of this characteristically different noncuring/nonhealing phenotye may provide important insight into common events involved in the development of the cell-mediated immune response to both visceral and subcutaneous forms of leishmaniasis.« less

  10. Low threshold interband cascade lasers operating above room temperature

    NASA Technical Reports Server (NTRS)

    Hill, C. J.; Yang, B.; Yang, R. Q.

    2003-01-01

    Mid-IR type-II interband cascade lasers were demonstrated in pulsed mode at temperatures up to 325 K and in continuous mode up to 200 K. At 80 K, the threshold current density was 8.9 A/cm2 and a cw outpout power of 140 mW/facet was obtained.

  11. Electrical percolation threshold of magnetostrictive inclusions in a piezoelectric matrix under simulated sintering conditions

    NASA Astrophysics Data System (ADS)

    Bedard, Antoine Joseph; Barbero, Ever J.

    2018-03-01

    Magnetoelectric (ME) composites can be produced by embedding magnetostrictive H particles in a piezoelectric E matrix derived from a piezoelectric powder precursor. Previously, using a bi-disperse hard-shell model (Barbero and Bedard in Comput Part Mech, 2018. https://doi.org/10.1007/s40571-017-0165-4), it has been shown that the electrical percolation threshold of the conductive H phase can be increased by decreasing the piezoelectric E particle size, relative to the H phase particle size, and by increasing short-range affinity between the E and H particles. This study builds on our previous study by exploring what happens during sintering of the ME composite when either the H or E particles undergo deformation. It was found that deformation of the H particles reduces the percolation threshold, and that deformation of E particles increases inter-phase H-E mechanical coupling, thus contributing to enhancing of ME coupling.

  12. Threshold level or not for low-density lipoprotein cholesterol.

    PubMed

    Barter, P J; Sacks, F M

    2001-05-01

    As drugs, such as the statins, and other therapies demonstrate the ability to significantly lower levels of low-density lipoprotein cholesterol (LDL-C), one issue is whether there is a lower threshold below which no further decline in coronary heart disease occurs. Those who evaluate the data from multiple trials and conclude that no significant decrease in coronary event rates occurs at or below 125 mg/dL suggest using this level as a guideline for clinical application of cholesterol-lowering therapy. On the other hand, analysis of the results of the same population and primary prevention studies concludes that no such threshold exists. The issues affected by the decision of whether to use a threshold include costs to the healthcare system for additional physician time, tests, and medication; unknown clinical events and safety related to very low LDL-C; and resource prioritization to an unestablished therapeutic approach.

  13. CHANGES IN FERRITIN H- AND L-CHAINS IN CANINE LENSES WITH AGE-RELATED NUCLEAR CATARACT

    PubMed Central

    Goralska, Małgorzata; Nagar, Steven; Colitz, Carmen M.H.; Fleisher, Lloyd N.; McGahan, M. Christine

    2014-01-01

    PURPOSE To determine potential differences in the characteristics of the iron storage protein, ferritin and its heavy (H) and light (L) subunits in fiber cells from cataractous and normal lenses of older dogs. METHODS Lens fiber cell homogenates were analyzed by SDS-PAGE and ferritin chains were immunodetected with ferritin chain-specific antibodies. Ferritin concentration was measured by ELISA. Immunohistochemistry was used to localize ferritin chains in lens sections. RESULTS The concentration of assembled ferritin was comparable in normal and cataractous lenses of similarly aged dogs. The ferritin L-chain detected in both lens types was modified and was about 11 kDa larger (30 kDa) than standard L-chain (19 kDa) purified from canine liver. The H-chain identified in cataractous fiber cells (29 kDa) differed from 21 kDa standard canine H-chain and from 12 kDa modified H-chain present in fiber cells of normal lenses. Histologic analysis revealed that the H-chain was distributed differently throughout cataractous lenses when compared to normal lenses. There was also a difference in subunit makeup of assembled ferritin between the two lens types. Ferritin from cataractous lenses contained more H-chain and bound 11-fold more iron than ferritin from normal lenses. CONCLUSIONS There are significant differences in the characteristics of ferritin H-chain and its distribution in canine cataractous lenses as compared to normal lenses. The higher content of H-chain in assembled ferritin allows this molecule to sequester more iron. In addition the accumulation of H-chain in deeper fiber layers of the lens may be part of a defense mechanism by which the cataractous lens limits iron-catalyzed oxidative damage. PMID:18708625

  14. Electrode Potentials of l-Tryptophan, l-Tyrosine, 3-Nitro-l-tyrosine, 2,3-Difluoro-l-tyrosine, and 2,3,5-Trifluoro-l-tyrosine.

    PubMed

    Mahmoudi, Leila; Kissner, Reinhard; Nauser, Thomas; Koppenol, Willem H

    2016-05-24

    Electrode potentials for aromatic amino acid radical/amino acid couples were deduced from cyclic voltammograms and pulse radiolysis experiments. The amino acids investigated were l-tryptophan, l-tyrosine, N-acetyl-l-tyrosine methyl ester, N-acetyl-3-nitro-l-tyrosine ethyl ester, N-acetyl-2,3-difluoro-l-tyrosine methyl ester, and N-acetyl-2,3,5-trifluoro-l-tyrosine methyl ester. Conditional potentials were determined at pH 7.4 for all compounds listed; furthermore, Pourbaix diagrams for l-tryptophan, l-tyrosine, and N-acetyl-3-nitro-l-tyrosine ethyl ester were obtained. Electron transfer accompanied by proton transfer is reversible, as confirmed by detailed analysis of the current waves, and because the slopes of the Pourbaix diagrams obey Nernst's law. E°'(Trp(•),H(+)/TrpH) and E°'(TyrO(•),H(+)/TyrOH) at pH 7 are 0.99 ± 0.01 and 0.97 ± 0.01 V, respectively. Pulse radiolysis studies of two dipeptides that contain both amino acids indicate a difference in E°' of approximately 0.06 V. Thus, in small peptides, we recommend values of 1.00 and 0.96 V for E°'(Trp(•),H(+)/TrpH) and E°'(TyrO(•),H(+)/TyrOH), respectively. The electrode potential of N-acetyl-3-nitro-l-tyrosine ethyl ester is higher, while because of mesomeric stabilization of the radical, those of N-acetyl-2,3-difluoro-l-tyrosine methyl ester and N-acetyl-2,3,5-trifluoro-l-tyrosine methyl ester are lower than that of tyrosine. Given that the electrode potentials at pH 7 of E°'(Trp(•),H(+)/TrpH) and E°'(TyrO(•),H(+)/TyrOH) are nearly equal, they would be, in principle, interchangeable. Proton-coupled electron transfer pathways in proteins that use TrpH and TyrOH are thus nearly thermoneutral.

  15. A 4H Silicon Carbide Gate Buffer for Integrated Power Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ericson, N; Frank, S; Britton, C

    2014-02-01

    A gate buffer fabricated in a 2-mu m 4H silicon carbide (SiC) process is presented. The circuit is composed of an input buffer stage with a push-pull output stage, and is fabricated using enhancement mode N-channel FETs in a process optimized for SiC power switching devices. Simulation and measurement results of the fabricated gate buffer are presented and compared for operation at various voltage supply levels, with a capacitive load of 2 nF. Details of the design including layout specifics, simulation results, and directions for future improvement of this buffer are presented. In addition, plans for its incorporation into anmore » isolated high-side/low-side gate-driver architecture, fully integrated with power switching devices in a SiC process, are briefly discussed. This letter represents the first reported MOSFET-based gate buffer fabricated in 4H SiC.« less

  16. Factors affecting perception thresholds of vertical whole-body vibration in recumbent subjects: Gender and age of subjects, and vibration duration

    NASA Astrophysics Data System (ADS)

    Matsumoto, Y.; Maeda, S.; Iwane, Y.; Iwata, Y.

    2011-04-01

    Some factors that may affect human perception thresholds of the vertical whole-body vibrations were investigated in two laboratory experiments with recumbent subjects. In the first experiment, the effects of gender and age of subjects on perception were investigated with three groups of 12 subjects, i.e., young males, young females and old males. For continuous sinusoidal vibrations at 2, 4, 8, 16, 31.5 and 63 Hz, there were no significant differences in the perception thresholds between male and female subjects, while the thresholds of young subjects tended to be significantly lower than the thresholds of old subjects. In the second experiment, the effect of vibration duration was investigated by using sinusoidal vibrations, at the same frequencies as above, modulated by the Hanning windows with different lengths (i.e., 0.5, 1.0, 2.0 and 4.0 s) for 12 subjects. It was found that the peak acceleration at the threshold tended to decrease with increasing duration of vibration. The perception thresholds were also evaluated by the running root-mean-square (rms) acceleration and the fourth power acceleration method defined in the current standards. The differences in the threshold of the transient vibrations for different durations were less with the fourth power acceleration method. Additionally, the effect of the integration time on the threshold was investigated for the running rms acceleration and the fourth power acceleration. It was found that the integration time that yielded less differences in the threshold of vibrations for different durations depended on the frequency of vibration.

  17. Diagnostic Dilemma for Low Viremia with Significant Fibrosis; Is HBV DNA Threshold Level a Good Indicator for Predicting Liver Damage?

    PubMed

    Yenilmez, Ercan; Çetinkaya, Rıza Aytaç; Tural, Ersin

    2018-05-04

    The most important difficulties about management of hepatitis B are still determining the liver damage and the right time to start antiviral therapy. To reveal the role of hepatitis B virus DNA threshold level for prediction of liver fibrosis and inflammation in young-aged hepatitis B e antigen negative chronic hepatitis B patients. Diagnostic accuracy study. A total of 273 hepatitis B e antigen negative young chronic hepatitis B patients with any hepatitis B virus DNA levels between 2008 and 2016, who had liver biopsy after at least 6 months follow up period, enrolled in this retrospective study. We created two groups as case and control, cases with hepatitis B virus DNA levels below 2.000 IU/mL and controls with hepatitis B virus DNA levels over 2.000 IU/mL. Having histological activity index ≥4 or/and fibrosis scores ≥2 were defined as significant histological abnormality. Then, we analyzed the relationship between these groups. We showed that significant fibrosis may occur in one third of young chronic hepatitis B patients with low viremia (30.2%, n=42/139 in cases, %55.2, n=74/134 in controls). Among the 42 cases with low viremia and significant fibrosis, 21.4% had alanine aminotransferase level between 40-59 U/L, 42.8% had alanine aminotransferase level between 60-79 U/L, and 35.7% had alanine aminotransferase level over 80 U/L. There was weak correlation between hepatitis B virus DNA threshold level and fibrosis score (p=0.000, rho=0.253). The optimum serum hepatitis B virus DNA threshold level in our study for predicting significant fibrosis was 1293 IU/mL (p=0.00, AUC: 0.657±0.034). The optimum alanine aminotransferase threshold level for predicting significant histological activity index and fibrosis was 64.5 and 59.5 U/L, respectively. The sensitivity and the specificity of 1293 vs 2000 IU/mL hepatitis B virus DNA threshold with 60 U/L alanine aminotransferase threshold level for predicting F≥2 fibrosis score were similar (sensitivity: 0.43 and 0

  18. Une complication rare des léiomyomes utérins: hémopéritoine massif par rupture de varices

    PubMed Central

    Ymele, Florent Fouelifack; Tsuala, Jovanny Fouogue; Fouedjio, Jeanne Hortence; Nangué, Charlette; De Kayo, Caroline Kayo; Dobgima, Pisoh Walter; Mbu, Robinson Enoh

    2013-01-01

    Les léiomyomes utérins sont des causes exceptionnelles d'hémopéritoine. Nous rapportons ici le cas d'une femme de 46 ans nullipare, en instance d'une hystérectomie totale indiquée pour utérus polymyomateux symptomatique. Elle a été opérée en urgence pour hémopéritoine aigu et massif compliqué de choc hémorragique. L'origine de l'hémopéritoine était la rupture spontanée d'une varice du léiomyome. Quoique rare l'éventualité d'un hémopéritoine causé par un fibrome utérin devrait être évoquée devant tout abdomen aigu spontané chez une femme en âge de procréer. La présence de varices sur les fibromes augmenterait le risque d'hémorragie spontanée. PMID:23717724

  19. Nasal inhalation of butorphanol in combination with ketamine quickly elevates the mechanical pain threshold in the model of chronic constriction injury to the sciatic nerve of rat.

    PubMed

    Chen, Feng; Wang, LiQin; Chen, ShuJun; Li, ZhiGao; Chen, ZhouLin; Zhou, XinHua; Zhai, Dong

    2014-01-01

    The aim of the present study is to explore the impact of butorphanol in combination with ketamine via nasal inhalation (NI) on neuropathic pain induced by chronic constriction injury (CCI) to the sciatic nerve in a rat model. CCI rats (n = 12) were equally randomized to four groups based on the treatments received as follows: 100 μL of 0.9% normal saline via NI (NS/NI group); 100 μg of butorphanol plus 1 mg of ketamine via NI (B + K/NI group); 100 μg of butorphanol alone via NI (B/NI group); and 100 μg of butorphanol plus 1 mg of ketamine via subcutaneous injection (B + K/SC group). Mechanical pain threshold was measured at 10 min, 30 min, 2 h, 4 h, and 6 h after drug administration. The mechanical pain threshold in the B + K/NI group was improved significantly 4 h after drug administration as compared with that in the B/NI or B + K/SC group (P < 0.05). The onset and intensity of drug action in the B + K/NI group were better than those of the other two groups, but the duration of drug action was not prolonged. NI of butorphanol in combination with ketamine quickly elevates the mechanical pain threshold in a rat neuropathic pain model induced by CCI to the sciatic nerve. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Ligand Field Strength Mediates Electron Delocalization in Octahedral [((H)L)2Fe6(L')m](n+) Clusters.

    PubMed

    Hernández Sánchez, Raúl; Zheng, Shao-Liang; Betley, Theodore A

    2015-09-02

    To assess the impact of terminal ligand binding on a variety of cluster properties (redox delocalization, ground-state stabilization, and breadth of redox state accessibility), we prepared three electron-transfer series based on the hexanuclear iron cluster [((H)L)2Fe6(L')m](n+) in which the terminal ligand field strength was modulated from weak to strong (L' = DMF, MeCN, CN). The extent of intracore M-M interactions is gauged by M-M distances, spin ground state persistence, and preference for mixed-valence states as determined by electrochemical comproportionation constants. Coordination of DMF to the [((H)L)2Fe6] core leads to weaker Fe-Fe interactions, as manifested by the observation of ground states populated only at lower temperatures (<100 K) and by the greater evidence of valence trapping within the mixed-valence states. Comproportionation constants determined electrochemically (Kc = 10(4)-10(8)) indicate that the redox series exhibits electronic delocalization (class II-III), yet no intervalence charge transfer (IVCT) bands are observable in the near-IR spectra. Ligation of the stronger σ donor acetonitrile results in stabilization of spin ground states to higher temperatures (∼300 K) and a high degree of valence delocalization (Kc = 10(2)-10(8)) with observable IVCT bands. Finally, the anionic cyanide-bound series reveals the highest degree of valence delocalization with the most intense IVCT bands (Kc = 10(12)-10(20)) and spin ground state population beyond room temperature. Across the series, at a given formal oxidation level, the capping ligand on the hexairon cluster dictates the overall properties of the aggregate, modulating the redox delocalization and the persistence of the intracore coupling of the metal sites.

  1. Exploiting Sub-threshold and above-threshold characteristics in a silver-enhanced gold nanoparticle based biochip.

    PubMed

    Liu, Yang; Alocilja, Evangelyn; Chakrabartty, Shantanu

    2009-01-01

    Silver-enhanced labeling is a technique used in immunochromatographic assays for improving the sensitivity of pathogen detection. In this paper, we employ the silver enhancement approach for constructing a biomolecular transistor that uses a high-density interdigitated electrode to detect rabbit IgG. We show that the response of the biomolecular transistor comprises of: (a) a sub-threshold region where the conductance change is an exponential function of the enhancement time and; (b) an above-threshold region where the conductance change is a linear function with respect to the enhancement time. By exploiting both these regions of operation, it is shown that the silver enhancing time is a reliable indicator of the IgG concentration. The method provides a relatively straightforward alternative to biomolecular signal amplification techniques. The measured results using a biochip prototype fabricated in silicon show that 240 pg/mL rabbit IgG can be detected at the silver enhancing time of 42 min. Also, the biomolecular transistor is compatible with silicon based processing making it ideal for designing integrated CMOS biosensors.

  2. 76 FR 77128 - Alternate Tonnage Threshold for Oil Spill Response Vessels

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-12

    ...The Coast Guard is establishing an alternate size threshold based on the measurement system established under the International Convention on Tonnage Measurement of Ships, 1969, for Oil Spill Response Vessels (OSRVs), which are properly certificated under 46 CFR subchapter L. The present size threshold of 500 gross registered tons is based on the U.S. regulatory measurement system. This rule provides an alternative for owners and operators of offshore supply vessels (OSVs) that may result in an increase in oil spill response capacity and capability.

  3. Application of phosphatidylethanol (PEth) in whole blood in comparison to ethyl glucuronide in hair (hEtG) in driving aptitude assessment (DAA).

    PubMed

    Schröck, Alexandra; Pfäffli, Matthias; König, Stefan; Weinmann, Wolfgang

    2016-11-01

    For driving aptitude assessment (DAA), the analysis of several alcohol biomarkers is essential for the detection of alcohol intake besides psycho-medical exploration. In Switzerland, EtG in hair (hEtG) is often the only direct marker for abstinence monitoring in DAA. Therefore, the suitability of phosphatidylethanol (PEth) was investigated as additional biomarker. PEth 16:0/18:1 and 16:0/18:2 were determined by online-SPE-LC-MS/MS in 136 blood samples of persons undergoing DAA and compared to hEtG, determined in hair segments taken at the same time. With a PEth 16:0/18:1 threshold of 210 ng/mL for excessive alcohol consumption, all (n = 30) but one tested person also had hEtG values ≥30 pg/mg. In 54 cases, results are not in contradiction to an abstinence as neither PEth (<20 ng/mL) nor hEtG (<7 pg/mg) was detected. In eight cases, both markers showed moderate consumption. Altogether, PEth and hEtG were in accordance in 68 % of the samples, although covering different time periods of alcohol consumption. With receiver operating characteristic analysis, PEth was evaluated to differentiate abstinence, moderate, and excessive alcohol consumption in accordance with hEtG limits. A PEth 16:0/18:1 threshold of 150 ng/mL resulted in the best sensitivity (70.6 %) and specificity (98.8 %) for excessive consumption. Values between 20 and 150 ng/mL passed for moderate consumption, values <20 ng/mL passed for abstinence. As PEth mostly has a shorter detection window (2-4 weeks) than hEtG (up to 6 months depending on hair length), changes in drinking behavior can be detected earlier by PEth than by hEtG analysis alone. Therefore, PEth helps to improve the diagnostic information and is a valuable additional alcohol marker for DAA.

  4. Gas breakdown driven by L band short-pulse high-power microwave

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang Yiming; Yuan Chengwei; Qian Baoliang

    2012-12-15

    High power microwave (HPM) driven gas breakdown is a major factor in limiting the radiation and transmission of HPM. A method that HPM driven gas breakdown could be obtained by changing the aperture of horn antenna is studied in this paper. Changing the effective aperture of horn antenna can adjust the electric field in near field zone, leading to gas breakdown. With this method, measurements of air and SF{sub 6} breakdowns are carried out on a magnetically insulated transmission-line oscillators, which is capable of generating HPM with pulse duration of 30 ns, and frequency of 1.74 GHz. The typical breakdownmore » waveforms of air and SF{sub 6} are presented. Besides, the breakdown field strengths of the two gases are derived at different pressures. It is found that the effects of air and SF{sub 6} breakdown on the transmission of HPM are different: air breakdown mainly shortens the pulse width of HPM while SF{sub 6} breakdown mainly reduces the peak output power of HPM. The electric field threshold of SF{sub 6} is about 2.4 times larger than that of air. These differences suggest that gas properties have a great effect on the transmission characteristic of HPM in gases.« less

  5. Syntheses of halogen derivatives of L-tryptophan, L-tyrosine and L-phenylalanine labeled with hydrogen isotopes.

    PubMed

    Pająk, Małgorzata; Pałka, Katarzyna; Winnicka, Elżbieta; Kańska, Marianna

    2016-01-01

    Halogenated, labeled with tritium and doubly with deuterium and tritium, derivatives of L-tryptophan, i.e. 5'-bromo-[2-(3)H]-, 5'-bromo-[2-(2)H/(3)H]-, 5'-fluoro-[2-(3)H]-5'-fluoro-[2-(2)H/(3)H]-, 6'-fluoro-[2-(3)H]-, 6'-fluoro-[2-(2)H/(3)H]-L-tryptophan, as well as, L-tyrosine, i.e. 3'-fluoro-[2-(3)H]-, 3'-fluoro-[2-(2)H/(3)H]-, 3'-chloro-[2-(3)H]-, and 3'-chloro-[2-(2)H/(3)H]-L-tyrosine, and also L-phenylalanine, i.e. 2'-fluoro-[(3S)-(3)H]-, 2'-fluoro-[(3S)-(2)H/(3) H]-, 2'-chloro-[(3S)-(3)H]-, 2'-chloro-[(3S)-(2)H/(3)H]-, 4'-chloro-[(3S)-(3)H]-, and 4'-chloro-[(3S)-(2)H/(3)H]-L-phenylalanine were synthesized using enzymatic methods. Isotopomers of L-tryptophan were synthesized by coupling of halogenated indoles with S-methyl-L-cysteine carried out in deuteriated or tritiated incubation media. Labeled halogenated derivatives of L-tyrosine were obtained by the enzymatically supported exchange between halogenated L-tyrosine and isotopic water. Labeled halogenated isotopologues of L-Phe were synthesized by the enzymatic addition of ammonia to halogenated cinnamic acid. As a source of hydrogen tritiated water (HTO) and heavy water (D2O) with addition of HTO were used. Copyright © 2015 John Wiley & Sons, Ltd.

  6. Variable threshold method for ECG R-peak detection.

    PubMed

    Kew, Hsein-Ping; Jeong, Do-Un

    2011-10-01

    In this paper, a wearable belt-type ECG electrode worn around the chest by measuring the real-time ECG is produced in order to minimize the inconvenient in wearing. ECG signal is detected using a potential instrument system. The measured ECG signal is transmits via an ultra low power consumption wireless data communications unit to personal computer using Zigbee-compatible wireless sensor node. ECG signals carry a lot of clinical information for a cardiologist especially the R-peak detection in ECG. R-peak detection generally uses the threshold value which is fixed. There will be errors in peak detection when the baseline changes due to motion artifacts and signal size changes. Preprocessing process which includes differentiation process and Hilbert transform is used as signal preprocessing algorithm. Thereafter, variable threshold method is used to detect the R-peak which is more accurate and efficient than fixed threshold value method. R-peak detection using MIT-BIH databases and Long Term Real-Time ECG is performed in this research in order to evaluate the performance analysis.

  7. An adaptive design for updating the threshold value of a continuous biomarker.

    PubMed

    Spencer, Amy V; Harbron, Chris; Mander, Adrian; Wason, James; Peers, Ian

    2016-11-30

    Potential predictive biomarkers are often measured on a continuous scale, but in practice, a threshold value to divide the patient population into biomarker 'positive' and 'negative' is desirable. Early phase clinical trials are increasingly using biomarkers for patient selection, but at this stage, it is likely that little will be known about the relationship between the biomarker and the treatment outcome. We describe a single-arm trial design with adaptive enrichment, which can increase power to demonstrate efficacy within a patient subpopulation, the parameters of which are also estimated. Our design enables us to learn about the biomarker and optimally adjust the threshold during the study, using a combination of generalised linear modelling and Bayesian prediction. At the final analysis, a binomial exact test is carried out, allowing the hypothesis that 'no population subset exists in which the novel treatment has a desirable response rate' to be tested. Through extensive simulations, we are able to show increased power over fixed threshold methods in many situations without increasing the type-I error rate. We also show that estimates of the threshold, which defines the population subset, are unbiased and often more precise than those from fixed threshold studies. We provide an example of the method applied (retrospectively) to publically available data from a study of the use of tamoxifen after mastectomy by the German Breast Study Group, where progesterone receptor is the biomarker of interest. © 2016 The Authors. Statistics in Medicine published by John Wiley & Sons Ltd. © 2016 The Authors. Statistics in Medicine published by John Wiley & Sons Ltd.

  8. Spectroscopic Constants and Vibrational Frequencies for l-C3H+ and Isotopologues from Highly-Accurate Quartic Force Fields: The Detection of l-C3H+ in the Horsehead Nebula PDR Questioned

    NASA Technical Reports Server (NTRS)

    Huang, Xinchuan; Fortenberry, Ryan Clifton; Lee, Timothy J.

    2013-01-01

    Very recently, molecular rotational transitions observed in the photon-dominated region of the Horsehead nebula have been attributed to l-C3H+. In an effort to corroborate this finding, we employed state-of-the art and proven high-accuracy quantum chemical techniques to compute spectroscopic constants for this cation and its isotopologues. Even though the B rotational constant from the fit of the observed spectrum and our computations agree to within 20 MHz, a typical level of accuracy, the D rotational constant differs by more than 40%, while the H rotational constant differs by three orders of magnitude. With the likely errors in the rotational transition energies resulting from this difference in D on the order of 1 MHz for the lowest observed transition (J = 4 yields 3) and growing as J increases, the assignment of the observed rotational lines from the Horsehead nebula to l-C3H+ is questionable.

  9. A Dynamical Threshold for Cardiac Delayed Afterdepolarization-Mediated Triggered Activity.

    PubMed

    Liu, Michael B; Ko, Christopher Y; Song, Zhen; Garfinkel, Alan; Weiss, James N; Qu, Zhilin

    2016-12-06

    Ventricular myocytes are excitable cells whose voltage threshold for action potential (AP) excitation is ∼-60 mV at which I Na is activated to give rise to a fast upstroke. Therefore, for a short stimulus pulse to elicit an AP, a stronger stimulus is needed if the resting potential lies further away from the I Na threshold, such as in hypokalemia. However, for an AP elicited by a long duration stimulus or a diastolic spontaneous calcium release, we observed that the stimulus needed was lower in hypokalemia than in normokalemia in both computer simulations and experiments of rabbit ventricular myocytes. This observation provides insight into why hypokalemia promotes calcium-mediated triggered activity, despite the resting potential lying further away from the I Na threshold. To understand the underlying mechanisms, we performed bifurcation analyses and demonstrated that there is a dynamical threshold, resulting from a saddle-node bifurcation mainly determined by I K1 and I NCX . This threshold is close to the voltage at which I K1 is maximum, and lower than the I Na threshold. After exceeding this dynamical threshold, the membrane voltage will automatically depolarize above the I Na threshold due to the large negative slope of the I K1 -V curve. This dynamical threshold becomes much lower in hypokalemia, especially with respect to calcium, as predicted by our theory. Because of the saddle-node bifurcation, the system can automatically depolarize even in the absence of I Na to voltages higher than the I Ca,L threshold, allowing for triggered APs in single myocytes with complete I Na block. However, because I Na is important for AP propagation in tissue, blocking I Na can still suppress premature ventricular excitations in cardiac tissue caused by calcium-mediated triggered activity. This suppression is more effective in normokalemia than in hypokalemia due to the difference in dynamical thresholds. Copyright © 2016 Biophysical Society. Published by Elsevier Inc

  10. Theoretical temperature-dependent branching ratios and laser thresholds of the 3F4 to 3H6 levels of Tm(3+) in ten garnets

    NASA Technical Reports Server (NTRS)

    Filer, Elizabeth D.; Barnes, Norman P.; Morrison, Clyde A.

    1991-01-01

    The calculated energy levels, the branching ratios, and the estimated thresholds for thulium operating on the 3F4 to 3H6 transitions are reported. Garnet materials with the general formula A3B2C3O12 are evaluated. Calculations are performed for the A side under the assumption of D2 symmetry. X-ray data available in the literature are used to evaluate the crystal-field components, A sub nm. Even-n components are employed to calculate the crystal-field splittings within the manifold. Thermal occupation factors are determined in a straightforward manner using a Boltzmann distribution for the respective manifolds. Odd-n components are applied to calculate the transition probabilities for electric field transitions. It is determined that the magnetic dipole contributions to the transition probability are comparable to the electric dipole contributions in some cases. Thresholds as a function of the density of thulium atoms are calculated.

  11. The design of a linear L-band high power amplifier for mobile communication satellites

    NASA Technical Reports Server (NTRS)

    Whittaker, N.; Brassard, G.; Li, E.; Goux, P.

    1990-01-01

    A linear L-band solid state high power amplifier designed for the space segment of the Mobile Satellite (MSAT) mobile communication system is described. The amplifier is capable of producing 35 watts of RF power with multitone signal at an efficiency of 25 percent and with intermodulation products better than 16 dB below carrier.

  12. Epithelial Coculture and l-Lactate Promote Growth of Helicobacter cinaedi under H2-Free Aerobic Conditions

    PubMed Central

    Taniguchi, Takako; Misawa, Naoaki

    2016-01-01

    ABSTRACT Helicobacter cinaedi is an emerging opportunistic pathogen associated with infections of diverse anatomic sites. Nevertheless, the species demonstrates fastidious axenic growth; it has been described as requiring a microaerobic atmosphere, along with a strong preference for supplemental H2 gas. In this context, we examined the hypothesis that in vitro growth of H. cinaedi could be enhanced by coculture with human epithelial cells. When inoculated (in Ham's F12 medium) over Caco-2 monolayers, the type strain (ATCC BAA-847) gained the ability to proliferate under H2-free aerobic conditions. Identical results were observed during coculture with several other monolayer types (LS-174T, AGS, and HeLa). Under chemically defined conditions, 40 amino acids and carboxylates were screened for their effect on the organism's atmospheric requirements. Several molecules promoted H2-free aerobic proliferation, although it occurred most prominently with millimolar concentrations of l-lactate. The growth response of H. cinaedi to Caco-2 cells and l-lactate was confirmed with a collection of 12 human-derived clinical strains. mRNA sequencing was next performed on the type strain under various growth conditions. In addition to providing a whole-transcriptome profile of H. cinaedi, this analysis demonstrated strong constitutive expression of the l-lactate utilization locus, as well as differential transcription of terminal respiratory proteins as a function of Caco-2 coculture and l-lactate supplementation. Overall, these findings challenge traditional views of H. cinaedi as an obligate microaerophile. IMPORTANCE H. cinaedi is an increasingly recognized pathogen in people with compromised immune systems. Atypical among other members of its bacterial class, H. cinaedi has been associated with infections of diverse anatomic sites. Growing H. cineadi in the laboratory is quite difficult, due in large part to the need for a specialized atmosphere. The suboptimal growth of H

  13. Rupture threshold characterization of polymer-shelled ultrasound contrast agents subjected to static overpressure

    NASA Astrophysics Data System (ADS)

    Chitnis, Parag V.; Lee, Paul; Mamou, Jonathan; Allen, John S.; Böhmer, Marcel; Ketterling, Jeffrey A.

    2011-04-01

    Polymer-shelled micro-bubbles are employed as ultrasound contrast agents (UCAs) and vesicles for targeted drug delivery. UCA-based delivery of the therapeutic payload relies on ultrasound-induced shell rupture. The fragility of two polymer-shelled UCAs manufactured by Point Biomedical or Philips Research was investigated by characterizing their response to static overpressure. The nominal diameters of Point and Philips UCAs were 3 μm and 2 μm, respectively. The UCAs were subjected to static overpressure in a glycerol-filled test chamber with a microscope-reticule lid. UCAs were reconstituted in 0.1 mL of water and added over the glycerol surface in contact with the reticule. A video-microscope imaged UCAs as glycerol was injected (5 mL/h) to vary the pressure from 2 to 180 kPa over 1 h. Neither UCA population responded to overpressure until the rupture threshold was exceeded, which resulted in abrupt destruction. The rupture data for both UCAs indicated three subclasses that exhibited different rupture behavior, although their mean diameters were not statistically different. The rupture pressures provided a measure of UCA fragility; the Philips UCAs were more resilient than Point UCAs. Results were compared to theoretical models of spherical shells under compression. Observed variations in rupture pressures are attributed to shell imperfections. These results may provide means to optimize polymeric UCAs for drug delivery and elucidate associated mechanisms.

  14. Resonances and thresholds in the Rydberg-level population of multiply charged ions at solid surfaces

    NASA Astrophysics Data System (ADS)

    Nedeljković, Lj. D.; Nedeljković, N. N.

    1998-12-01

    We present a theoretical study of resonances and thresholds, two specific features of Rydberg-state formation of multiply charged ions (Z=6, 7, and 8) escaping a solid surface at intermediate velocities (v~1 a.u.) in the normal emergence geometry. The resonances are recognized in pronounced maxima of the experimentally observed population curves of Ar VIII ions for resonant values of the principal quantum number n=nres=11 and for the angular momentum quantum numbers l=1 and 2. Absence of optical signals in detectors of beam-foil experiments for n>nthr of S VI and Cl VII ions (with l=0, 1, and 2) and Ar VIII for l=0 is interpreted as a threshold phenomenon. An interplay between resonance and threshold effects is established within the framework of quantum dynamics of the low angular momentum Rydberg-state formation, based on a generalization of Demkov-Ostrovskii's charge-exchange model. In the model proposed, the Ar VIII resonances appear as a consequence of electron tunneling in the very vicinity of the ion-surface potential barrier top and at some critical ion-surface distances Rc. The observed thresholds are explained by means of a decay mechanism of ionic Rydberg states formed dominantly above the Fermi level EF of a solid conduction band. The theoretically predicted resonant and threshold values, nres and nthr of the principal quantum number n, as well as the obtained population probabilities Pnl=Pnl(v,Z), are in sufficiently good agreement with all available experimental findings.

  15. Methylene blue counteracts H2S toxicity-induced cardiac depression by restoring L-type Ca channel activity

    PubMed Central

    Zhang, Xue-Qian; Sonobe, Takashi; Song, Jianliang; Rannals, Matthew D.; Wang, JuFang; Tubbs, Nicole; Cheung, Joseph Y.; Haouzi, Philippe

    2016-01-01

    We have previously reported that methylene blue (MB) can counteract hydrogen sulfide (H2S) intoxication-induced circulatory failure. Because of the multifarious effects of high concentrations of H2S on cardiac function, as well as the numerous properties of MB, the nature of this interaction, if any, remains uncertain. The aim of this study was to clarify 1) the effects of MB on H2S-induced cardiac toxicity and 2) whether L-type Ca2+ channels, one of the targets of H2S, could transduce some of the counteracting effects of MB. In sedated rats, H2S infused at a rate that would be lethal within 5 min (24 μM·kg−1·min−1), produced a rapid fall in left ventricle ejection fraction, determined by echocardiography, leading to a pulseless electrical activity. Blood concentrations of gaseous H2S reached 7.09 ± 3.53 μM when cardiac contractility started to decrease. Two to three injections of MB (4 mg/kg) transiently restored cardiac contractility, blood pressure, and V̇o2, allowing the animals to stay alive until the end of H2S infusion. MB also delayed PEA by several minutes following H2S-induced coma and shock in unsedated rats. Applying a solution containing lethal levels of H2S (100 μM) on isolated mouse cardiomyocytes significantly reduced cell contractility, intracellular calcium concentration ([Ca2+]i) transient amplitudes, and L-type Ca2+ currents (ICa) within 3 min of exposure. MB (20 mg/l) restored the cardiomyocyte function, ([Ca2+]i) transient, and ICa. The present results offer a new approach for counteracting H2S toxicity and potentially other conditions associated with acute inhibition of L-type Ca2+ channels. PMID:26962024

  16. Determination of minimal steady-state plasma level of diazepam causing seizure threshold elevation in rats.

    PubMed

    Dhir, Ashish; Rogawski, Michael A

    2018-05-01

    Diazepam, administered by the intravenous, oral, or rectal routes, is widely used for the management of acute seizures. Dosage forms for delivery of diazepam by other routes of administration, including intranasal, intramuscular, and transbuccal, are under investigation. In predicting what dosages are necessary to terminate seizures, the minimal exposure required to confer seizure protection must be known. Here we administered diazepam by continuous intravenous infusion to obtain near-steady-state levels, which allowed an assessment of the minimal levels that elevate seizure threshold. The thresholds for various behavioral seizure signs (myoclonic jerk, clonus, and tonus) were determined with the timed intravenous pentylenetetrazol seizure threshold test in rats. Diazepam was administered to freely moving animals by continuous intravenous infusion via an indwelling jugular vein cannula. Blood samples for assay of plasma levels of diazepam and metabolites were recovered via an indwelling cannula in the contralateral jugular vein. The pharmacokinetic parameters of diazepam following a single 80-μg/kg intravenous bolus injection were determined using a noncompartmental pharmacokinetic approach. The derived parameters V d , CL, t 1/2α (distribution half-life) and t 1/2β (terminal half-life) for diazepam were, respectively, 608 mL, 22.1 mL/min, 13.7 minutes, and 76.8 minutes, respectively. Various doses of diazepam were continuously infused without or with an initial loading dose. At the end of the infusions, the thresholds for various behavioral seizure signs were determined. The minimal plasma diazepam concentration associated with threshold elevations was estimated at approximately 70 ng/mL. The active metabolites nordiazepam, oxazepam, and temazepam achieved levels that are expected to make only minor contributions to the threshold elevations. Diazepam elevates seizure threshold at steady-state plasma concentrations lower than previously recognized. The

  17. 77 FR 16968 - Airworthiness Directives; Burkhart GROB Luft- und Raumfahrt GmbH Powered Sailplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-23

    ... verbal contact we receive about this proposed AD. Discussion The European Aviation Safety Agency (EASA...-200. (h) Related Information Refer to MCAI European Aviation Safety Agency (EAS) AD No. 2012- 0027...- und Raumfahrt GmbH Powered Sailplanes AGENCY: Federal Aviation Administration (FAA), Department of...

  18. Ultralow-threshold microcavity Raman laser on a microelectronic chip

    NASA Astrophysics Data System (ADS)

    Kippenberg, T. J.; Spillane, S. M.; Armani, D. K.; Vahala, K. J.

    2004-06-01

    Using ultrahigh-Q toroid microcavities on a chip, we demonstrate a monolithic microcavity Raman laser. Cavity photon lifetimes in excess of 100 ns combined with mode volumes typically of less than 1000 µm^3 significantly reduce the threshold for stimulated Raman scattering. In conjunction with the high ideality of a tapered optical fiber coupling junction, stimulated Raman lasing is observed at an ultralow threshold (as low as 74 µW of fiber-launched power at 1550 nm) with high efficiency (up to 45% at the critical coupling point) in good agreement with theoretical modeling. Equally important, the wafer-scale nature of these devices should permit integration with other photonic, mechanical, or electrical functionality on a chip.

  19. Ultralow-threshold microcavity Raman laser on a microelectronic chip.

    PubMed

    Kippenberg, T J; Spillane, S M; Armani, D K; Vahala, K J

    2004-06-01

    Using ultrahigh-Q toroid microcavities on a chip, we demonstrate a monolithic microcavity Raman laser. Cavity photon lifetimes in excess of 100 ns combined with mode volumes typically of less than 1000 (microm)3 significantly reduce the threshold for stimulated Raman scattering. In conjunction with the high ideality of a tapered optical fiber coupling junction, stimulated Raman lasing is observed at an ultralow threshold (as low as 74 microW of fiber-launched power at 1550 nm) with high efficiency (up to 45% at the critical coupling point) in good agreement with theoretical modeling. Equally important, the wafer-scale nature of these devices should permit integration with other photonic, mechanical, or electrical functionality on a chip.

  20. Low threshold diode-pumped picosecond mode-locked Nd:YAG laser with a semiconductor saturable absorber mirror

    NASA Astrophysics Data System (ADS)

    Eshghi, M. J.; Majdabadi, A.; Koohian, A.

    2017-01-01

    In this paper, a low threshold diode pumped passively mode-locked Nd:YAG laser has been demonstrated by using a semiconductor saturable absorber mirror. The threshold power for continuous-wave mode-locking is relatively low, about 3.2 W. The resonator stability across the pump power has been analytically examined. Moreover, the mode overlap between the pump beam and the laser fundamental mode has been simulated by MATLAB software. Adopting Z-shaped resonator configuration and suitable design of the resonator’s arm lengths, has enabled the author to prepare mode-locking conditions, and obtain 40 ps pulses with 112 MHz pulse repetition rate. The laser output was stable without any Q switched instability. To the best of our knowledge, this is the lowest threshold for CW mode-locking operation of a Nd:YAG laser.

  1. Evidence for thermally assisted threshold switching behavior in nanoscale phase-change memory cells

    NASA Astrophysics Data System (ADS)

    Le Gallo, Manuel; Athmanathan, Aravinthan; Krebs, Daniel; Sebastian, Abu

    2016-01-01

    In spite of decades of research, the details of electrical transport in phase-change materials are still debated. In particular, the so-called threshold switching phenomenon that allows the current density to increase steeply when a sufficiently high voltage is applied is still not well understood, even though there is wide consensus that threshold switching is solely of electronic origin. However, the high thermal efficiency and fast thermal dynamics associated with nanoscale phase-change memory (PCM) devices motivate us to reassess a thermally assisted threshold switching mechanism, at least in these devices. The time/temperature dependence of the threshold switching voltage and current in doped Ge2Sb2Te5 nanoscale PCM cells was measured over 6 decades in time at temperatures ranging from 40 °C to 160 °C. We observe a nearly constant threshold switching power across this wide range of operating conditions. We also measured the transient dynamics associated with threshold switching as a function of the applied voltage. By using a field- and temperature-dependent description of the electrical transport combined with a thermal feedback, quantitative agreement with experimental data of the threshold switching dynamics was obtained using realistic physical parameters.

  2. Process dependency on threshold voltage of GaN MOSFET on AlGaN/GaN heterostructure

    NASA Astrophysics Data System (ADS)

    Wang, Qingpeng; Jiang, Ying; Miyashita, Takahiro; Motoyama, Shin-ichi; Li, Liuan; Wang, Dejun; Ohno, Yasuo; Ao, Jin-Ping

    2014-09-01

    GaN metal-oxide-semiconductor field-effect transistors (MOSFETs) with recessed gate on AlGaN/GaN heterostructure are reported in which the drain and source ohmic contacts were fabricated on the AlGaN/GaN heterostructure and the electron channel was formed on the GaN buffer layer by removing the AlGaN barrier layer. Negative threshold voltages were commonly observed in all devices. To investigate the reasons of the negative threshold voltages, different oxide thickness, etching gas and bias power of inductively-coupled plasma (ICP) system were utilized in the fabrication process of the GaN MOSFETs. It is found that positive charges of around 1 × 1012 q/cm2 exist near the interface at the just threshold condition in both silane- and tetraethylorthosilicate (TEOS)-based devices. It is also found that the threshold voltages do not obviously change with the different etching gas (SiCl4, BCl3 and two-step etching of SiCl4/Cl2) at the same ICP bias power level (20-25 W) and will become deeper when higher bias power is used in the dry recess process which may be related to the much serious ion bombardment damage. Furthermore, X-ray photoelectron spectroscopy (XPS) experiments were done to investigate the surface conditions. It is found that N 1s peaks become lower with higher bias power of the dry etching process. Also, silicon contamination was found and could be removed by HNO3/HF solution. It indicates that the nitrogen vacancies are mainly responsible for the negative threshold voltages rather than the silicon contamination. It demonstrates that optimization of the ICP recess conditions and improvement of the surface condition are still necessary to realize enhancement-mode GaN MOSFETs on AlGaN/GaN heterostructure.

  3. Underwater temporary threshold shift in pinnipeds: effects of noise level and duration.

    PubMed

    Kastak, David; Southall, Brandon L; Schusterman, Ronald J; Kastak, Colleen Reichmuth

    2005-11-01

    Behavioral psychophysical techniques were used to evaluate the residual effects of underwater noise on the hearing sensitivity of three pinnipeds: a California sea lion (Zalophus californianus), a harbor seal (Phoca vitulina), and a northern elephant seal (Mirounga angustirostris). Temporary threshold shift (TTS), defined as the difference between auditory thresholds obtained before and after noise exposure, was assessed. The subjects were exposed to octave-band noise centered at 2500 Hz at two sound pressure levels: 80 and 95 dB SL (re: auditory threshold at 2500 Hz). Noise exposure durations were 22, 25, and 50 min. Threshold shifts were assessed at 2500 and 3530 Hz. Mean threshold shifts ranged from 2.9-12.2 dB. Full recovery of auditory sensitivity occurred within 24 h of noise exposure. Control sequences, comprising sham noise exposures, did not result in significant mean threshold shifts for any subject. Threshold shift magnitudes increased with increasing noise sound exposure level (SEL) for two of the three subjects. The results underscore the importance of including sound exposure metrics (incorporating sound pressure level and exposure duration) in order to fully assess the effects of noise on marine mammal hearing.

  4. Individual anaerobic threshold estimates maximal lactate steady state in temperate and hot climate.

    PubMed

    De Barros, Cristiano L Monteiro; Mendes, Thiago T; Mortimer, Lucas De Ávila Castro Fleury; Ramos, Guilherme Passos; Garcia, Emerson Silami

    2016-01-01

    The aim of the present study was to compare the power output at the maximal lactate steady state (MLSS) with the power output at the individual anaerobic threshold (IAT) and at the onset of blood lactate accumulation (OBLA) in both temperate (TEMP) (22 °C) and hot (HOT) (40 °C) climates. Eight young active male (23.9±2.4 yr, 75.9±7.3 kg and 47.8±4.9 mL/kg/min) were evaluated on a cycle ergometer and performed a progressive exercise test until fatigue to determine the IAT and OBLA and two to five 30-min exercise tests at constant intensities for determine MLSS at both temperatures. An ANOVA with repeated measures and Dunnett's post-hoc test was performed to compare results of IAT and OBLA to the variables at the MLSS in both climates with MLSS being considered as the standard. At TEMP there was no difference between the power output at MLSS and IAT (180±11 W and 182±13 W, respectively), however, the intensity of the OBLA (154±11 W) was lower than MLSS (P<0.05). At HOT there was no difference between the power output at MLSS, IAT, and OBLA (148±11 W, 155±12 W and 144±11 W, respectively). These results showed that IAT is sensitive enough to estimate MLSS in both TEMP and HOT climate.

  5. Modulation of foot-and-mouth disease virus pH threshold for uncoating correlates with differential sensitivity to inhibition of cellular Rab GTPases and decreases infectivity in vivo.

    PubMed

    Vázquez-Calvo, Angela; Caridi, Flavia; Rodriguez-Pulido, Miguel; Borrego, Belén; Sáiz, Margarita; Sobrino, Francisco; Martín-Acebes, Miguel A

    2012-11-01

    The role of cellular Rab GTPases that govern traffic between different endosome populations was analysed on foot-and-mouth disease virus (FMDV) infection. Changes of viral receptor specificity did not alter Rab5 requirement for infection. However, a correlation between uncoating pH and requirement of Rab5 for infection was observed. A mutant FMDV with less acidic uncoating pH threshold was less sensitive to inhibition of Rab5, whereas another mutant with more acidic requirements was more sensitive to inhibition of Rab5. On the contrary, opposed correlations between uncoating pH and dependence of Rab function were observed upon expression of dominant-negative forms of Rab7 or 11. Modulation of uncoating pH also reduced FMDV virulence in suckling mice. These results are consistent with FMDV uncoating inside early endosomes and indicate that displacements from optimum pH for uncoating reduce viral fitness in vivo.

  6. Deriving freshwater safety thresholds for hexabromocyclododecane and comparison of toxicity of brominated flame retardants.

    PubMed

    Dong, Liang; Zheng, Lei; Yang, Suwen; Yan, Zhenguang; Jin, Weidong; Yan, Yuhong

    2017-05-01

    Hexabromocyclododecane (HBCD) is a brominated flame retardant used throughout the world. It has been detected in various environmental media and has been shown toxic to aquatic life. The toxic effects of HBCD to aquatic organisms in Chinese freshwater ecosystems are discussed here. Experiments were conducted with nine types of acute toxicity testing and three types of chronic toxicity testing. After comparing a range of species sensitivity distribution models, the optimal model of Bull III was used to derive the safety thresholds for HBCD. The acute safety threshold and the chronic safety threshold of HBCD for Chinese freshwater organisms were found to be 2.32mg/L and 0.128mg/L, respectively. Both values were verified by the methods of the Netherlands and the United States. HBCD was found to be less toxic compared to other widely used brominated flame retardants. The present results provide valuable information for revision of the water quality standard of HBCD in China. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Hydrogenated pyrene: Statistical single-carbon loss below the knockout threshold

    NASA Astrophysics Data System (ADS)

    Wolf, Michael; Giacomozzi, Linda; Gatchell, Michael; de Ruette, Nathalie; Stockett, Mark H.; Schmidt, Henning T.; Cederquist, Henrik; Zettergren, Henning

    2016-04-01

    An ongoing discussion revolves around the question of what effect hydrogenation has on carbon backbone fragmentation in polycyclic aromatic hydrocarbons (PAHs). In order to shed more light on this issue, we have measured absolute single carbon loss cross sections in collisions between native or hydrogenated pyrene cations (C16H+10+m, m = 0, 6, 16) and He as functions of center-of-mass energies down to 20 eV. Classical molecular dynamics (MD) simulations give further insight into energy transfer processes and also yield m-dependent threshold energies for prompt (femtoseconds) carbon knockout. Such fast, non-statistical fragmentation processes dominate CHx-loss for native pyrene (m = 0), while much slower statistical fragmentation processes contribute significantly to single-carbon loss for the hydrogenated molecules (m = 6 and m = 16). The latter is shown by measurements of large CHx-loss cross sections far below the MD knockout thresholds for C16H+16 and C16H+26. Contribution to the "Atomic Cluster Collisions (7th International Symposium)", edited by Gerardo Delgado Barrio, Andrey Solov'Yov, Pablo Villarreal, Rita Prosmiti.

  8. Identifying community thresholds for lotic benthic diatoms in response to human disturbance.

    PubMed

    Tang, Tao; Tang, Ting; Tan, Lu; Gu, Yuan; Jiang, Wanxiang; Cai, Qinghua

    2017-06-23

    Although human disturbance indirectly influences lotic assemblages through modifying physical and chemical conditions, identifying thresholds of human disturbance would provide direct evidence for preventing anthropogenic degradation of biological conditions. In the present study, we used data obtained from tributaries of the Three Gorges Reservoir in China to detect effects of human disturbance on streams and to identify disturbance thresholds for benthic diatoms. Diatom species composition was significantly affected by three in-stream stressors including TP, TN and pH. Diatoms were also influenced by watershed % farmland and natural environmental variables. Considering three in-stream stressors, TP was positively influenced by % farmland and % impervious surface area (ISA). In contrast, TN and pH were principally affected by natural environmental variables. Among measured natural environmental variables, average annual air temperature, average annual precipitation, and topsoil % CaCO 3 , % gravel, and total exchangeable bases had significant effects on study streams. When effects of natural variables were accounted for, substantial compositional changes in diatoms occurred when farmland or ISA land use exceeded 25% or 0.3%, respectively. Our study demonstrated the rationale for identifying thresholds of human disturbance for lotic assemblages and addressed the importance of accounting for effects of natural factors for accurate disturbance thresholds.

  9. A comparison of the DPSS UV laser ablation characteristic of 1024 and H10F WC-Co

    NASA Astrophysics Data System (ADS)

    See, Tian Long; Chantzis, Dimitrios; Royer, Raphael; Metsios, Ioannis; Antar, Mohammad; Marimuthu, Sundar

    2017-07-01

    An investigation on ablation characteristics of 1024 and H10F cobalt cemented tungsten carbide (WC-Co) with a DPSS nanosecond UV laser (50 ns pulse width, 355 nm wavelength, 90 W average power and 10 kHz repetition rate) is presented. The ablation characteristic parameters such as ablation threshold, incubation effect and optical penetration depth were evaluated based on the spot ablation diameter and depth. It was observed that the ablation threshold is significantly influenced by the number of pulses (NOP) and it decreases with increase NOP which is attributed to the incubation effect. Only one ablation region is observed at low laser fluence and an additional molten ablation region is observed at high laser fluence accompanied with cracks. The cracks formation is due to the thermal induced stress and changes in WC microstructure during laser beam irradiation. The crack depth is proportional to the thickness of the molten WC region. The ablation threshold of 1024 WC-Co and H10F WC-Co were found to be Fth1 =4.32 J/cm2 and Fth1 =4.26 J/cm2 respectively. The difference in chemical composition has insignificant effect on the ablation threshold value of the material. The incubation factor and optical penetration depth values of 1024 WC-Co and H10F WC-Co were found to be ξ=0.73, α-1 =411 nm and ξ=0.75, α-1 =397 nm respectively.

  10. Epstein-Barr virus glycoprotein gH/gL antibodies complement IgA-viral capsid antigen for diagnosis of nasopharyngeal carcinoma

    PubMed Central

    Tang, Lin-Quan; Zhang, Hua; Li, Yan; Liu, Wan-Li; Zhong, Qian; Zeng, Mu-Sheng; Huang, Xiao-Ming

    2016-01-01

    To determine whether measuring antibodies against Epstein-Barr virus (EBV) glycoprotein gH/gL in serum could improve diagnostic accuracy in nasopharyngeal carcinoma (NPC) cases, gH/gL expressed in a recombinant baculovirus system was used in an enzyme-linked immunosorbent assay (ELISA) to detect antibodies in two independent cohorts. Binary logistic regression analyses were performed using results from a training cohort (n = 406) to establish diagnostic mathematical models, which were validated in a second independent cohort (n = 279). Levels of serum gH/gL antibodies were higher in NPC patients than in healthy controls (p < 0.001). In the training cohort, the IgA-gH/gL ELISA had a sensitivity of 83.7%, specificity of 82.3% and area under the curve (AUC) of 0.893 (95% CI, 0.862-0.924) for NPC diagnosis. Furthermore, gH/gL maintained diagnostic capacity in IgA-VCA negative NPC patients (sensitivity = 78.1%, specificity = 82.3%, AUC = 0.879 [95% CI, 0.820 - 0.937]). Combining gH/gL and viral capsid antigen (VCA) detection improved diagnostic capacity as compared to individual tests alone in both the training cohort (sensitivity = 88.5%, specificity = 97%, AUC = 0.98 [95% CI, 0.97 - 0.991]), and validation cohort (sensitivity = 91.2%, specificity = 96.5%, AUC = 0.97 [95% CI, 0.951-0.988]). These findings suggest that EBV gH/gL detection complements VCA detection in the diagnosis of NPC and aids in the identification of patients with VCA-negative NPC. PMID:27093005

  11. Properties of perimetric threshold estimates from Full Threshold, SITA Standard, and SITA Fast strategies.

    PubMed

    Artes, Paul H; Iwase, Aiko; Ohno, Yuko; Kitazawa, Yoshiaki; Chauhan, Balwantray C

    2002-08-01

    To investigate the distributions of threshold estimates with the Swedish Interactive Threshold Algorithms (SITA) Standard, SITA Fast, and the Full Threshold algorithm (Humphrey Field Analyzer; Zeiss-Humphrey Instruments, Dublin, CA) and to compare the pointwise test-retest variability of these strategies. One eye of 49 patients (mean age, 61.6 years; range, 22-81) with glaucoma (Mean Deviation mean, -7.13 dB; range, +1.8 to -23.9 dB) was examined four times with each of the three strategies. The mean and median SITA Standard and SITA Fast threshold estimates were compared with a "best available" estimate of sensitivity (mean results of three Full Threshold tests). Pointwise 90% retest limits (5th and 95th percentiles of retest thresholds) were derived to assess the reproducibility of individual threshold estimates. The differences between the threshold estimates of the SITA and Full Threshold strategies were largest ( approximately 3 dB) for midrange sensitivities ( approximately 15 dB). The threshold distributions of SITA were considerably different from those of the Full Threshold strategy. The differences remained of similar magnitude when the analysis was repeated on a subset of 20 locations that are examined early during the course of a Full Threshold examination. With sensitivities above 25 dB, both SITA strategies exhibited lower test-retest variability than the Full Threshold strategy. Below 25 dB, the retest intervals of SITA Standard were slightly smaller than those of the Full Threshold strategy, whereas those of SITA Fast were larger. SITA Standard may be superior to the Full Threshold strategy for monitoring patients with visual field loss. The greater test-retest variability of SITA Fast in areas of low sensitivity is likely to offset the benefit of even shorter test durations with this strategy. The sensitivity differences between the SITA and Full Threshold strategies may relate to factors other than reduced fatigue. They are, however, small in

  12. Impact of E × B flow shear on turbulence and resulting power fall-off width in H-mode plasmas in experimental advanced superconducting tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Q. Q., E-mail: yangqq@ipp.ac.cn; Zhong, F. C., E-mail: gsxu@ipp.ac.cn, E-mail: fczhong@dhu.edu.cn; Jia, M. N.

    2015-06-15

    The power fall-off width in the H-mode scrape-off layer (SOL) in tokamaks shows a strong inverse dependence on the plasma current, which was noticed by both previous multi-machine scaling work [T. Eich et al., Nucl. Fusion 53, 093031 (2013)] and more recent work [L. Wang et al., Nucl. Fusion 54, 114002 (2014)] on the Experimental Advanced Superconducting Tokamak. To understand the underlying physics, probe measurements of three H-mode discharges with different plasma currents have been studied in this work. The results suggest that a higher plasma current is accompanied by a stronger E×B shear and a shorter radial correlation lengthmore » of turbulence in the SOL, thus resulting in a narrower power fall-off width. A simple model has also been applied to demonstrate the suppression effect of E×B shear on turbulence in the SOL and shows relatively good agreement with the experimental observations.« less

  13. Experimental and theoretical characterization of deep penetration welding threshold induced by 1-μm laser

    NASA Astrophysics Data System (ADS)

    Zou, J. L.; He, Y.; Wu, S. K.; Huang, T.; Xiao, R. S.

    2015-12-01

    The deep penetration-welding threshold (DPWT) is the critical value that describes the welding mode transition from the thermal conduction to the deep penetration. The objective of this research is to clarify the DPWT induced by the lasers with wavelength of 1 μm (1-μm laser), based on experimental observation and theoretical analysis. The experimental results indicated that the DPWT was the ratio between laser power and laser spot diameter (P/d) rather than laser power density (P/S). The evaporation threshold was smaller than the DPWT, while the jump threshold of the evaporated mass flux in the molten pool surface was consistent with the DPWT. Based on the force balance between the evaporation recoil pressure and the surface tension pressure at the gas-liquid interface of the molten pool as well as the temperature field, we developed a self-focusing model, which further confirmed the experimental results.

  14. Oscillatory Threshold Logic

    PubMed Central

    Borresen, Jon; Lynch, Stephen

    2012-01-01

    In the 1940s, the first generation of modern computers used vacuum tube oscillators as their principle components, however, with the development of the transistor, such oscillator based computers quickly became obsolete. As the demand for faster and lower power computers continues, transistors are themselves approaching their theoretical limit and emerging technologies must eventually supersede them. With the development of optical oscillators and Josephson junction technology, we are again presented with the possibility of using oscillators as the basic components of computers, and it is possible that the next generation of computers will be composed almost entirely of oscillatory devices. Here, we demonstrate how coupled threshold oscillators may be used to perform binary logic in a manner entirely consistent with modern computer architectures. We describe a variety of computational circuitry and demonstrate working oscillator models of both computation and memory. PMID:23173034

  15. Oscillatory threshold logic.

    PubMed

    Borresen, Jon; Lynch, Stephen

    2012-01-01

    In the 1940s, the first generation of modern computers used vacuum tube oscillators as their principle components, however, with the development of the transistor, such oscillator based computers quickly became obsolete. As the demand for faster and lower power computers continues, transistors are themselves approaching their theoretical limit and emerging technologies must eventually supersede them. With the development of optical oscillators and Josephson junction technology, we are again presented with the possibility of using oscillators as the basic components of computers, and it is possible that the next generation of computers will be composed almost entirely of oscillatory devices. Here, we demonstrate how coupled threshold oscillators may be used to perform binary logic in a manner entirely consistent with modern computer architectures. We describe a variety of computational circuitry and demonstrate working oscillator models of both computation and memory.

  16. Compressively sampled MR image reconstruction using generalized thresholding iterative algorithm

    NASA Astrophysics Data System (ADS)

    Elahi, Sana; kaleem, Muhammad; Omer, Hammad

    2018-01-01

    Compressed sensing (CS) is an emerging area of interest in Magnetic Resonance Imaging (MRI). CS is used for the reconstruction of the images from a very limited number of samples in k-space. This significantly reduces the MRI data acquisition time. One important requirement for signal recovery in CS is the use of an appropriate non-linear reconstruction algorithm. It is a challenging task to choose a reconstruction algorithm that would accurately reconstruct the MR images from the under-sampled k-space data. Various algorithms have been used to solve the system of non-linear equations for better image quality and reconstruction speed in CS. In the recent past, iterative soft thresholding algorithm (ISTA) has been introduced in CS-MRI. This algorithm directly cancels the incoherent artifacts produced because of the undersampling in k -space. This paper introduces an improved iterative algorithm based on p -thresholding technique for CS-MRI image reconstruction. The use of p -thresholding function promotes sparsity in the image which is a key factor for CS based image reconstruction. The p -thresholding based iterative algorithm is a modification of ISTA, and minimizes non-convex functions. It has been shown that the proposed p -thresholding iterative algorithm can be used effectively to recover fully sampled image from the under-sampled data in MRI. The performance of the proposed method is verified using simulated and actual MRI data taken at St. Mary's Hospital, London. The quality of the reconstructed images is measured in terms of peak signal-to-noise ratio (PSNR), artifact power (AP), and structural similarity index measure (SSIM). The proposed approach shows improved performance when compared to other iterative algorithms based on log thresholding, soft thresholding and hard thresholding techniques at different reduction factors.

  17. Impact of muon detection thresholds on the separability of primary cosmic rays

    NASA Astrophysics Data System (ADS)

    Müller, S.; Engel, R.; Pierog, T.; Roth, M.

    2018-01-01

    Knowledge of the mass composition of cosmic rays in the transition region of galactic to extragalactic cosmic rays is needed to discriminate different astrophysical models on their origin, acceleration, and propagation. An important observable to separate different mass groups of cosmic rays is the number of muons in extensive air showers. We performed a CORSIKA simulation study to analyze the impact of the detection threshold of muons on the separation quality of different primary cosmic rays in the energy region of the ankle. Using only the number of muons as the composition-sensitive observable, we find a clear dependence of the separation power on the detection threshold for ideal measurements. Although the number of detected muons increases when lowering the threshold, the discrimination power is reduced. If statistical fluctuations for muon detectors of limited size are taken into account, the threshold dependence remains qualitatively the same for small distances to the shower core but is reduced for large core distances. We interpret the impact of the detection threshold of muons on the composition sensitivity in terms of a change of the correlation of the number of muons nμ with the shower maximum Xmax as function of the muon energy as a result of the underlying hadronic interactions and the shower geometry. We further investigate the role of muons produced in a shower by photon-air interactions and conclude that, in addition to the effect of the nμ -Xmax correlation, the separability of primaries is reduced as a consequence of the presence of more muons from photonuclear reactions in proton than in iron showers.

  18. Digital audio watermarking using moment-preserving thresholding

    NASA Astrophysics Data System (ADS)

    Choi, DooSeop; Jung, Hae Kyung; Choi, Hyuk; Kim, Taejeong

    2007-09-01

    The Moment-Preserving Thresholding technique for digital images has been used in digital image processing for decades, especially in image binarization and image compression. Its main strength lies in that the binary values that the MPT produces as a result, called representative values, are usually unaffected when the signal being thresholded goes through a signal processing operation. The two representative values in MPT together with the threshold value are obtained by solving the system of the preservation equations for the first, second, and third moment. Relying on this robustness of the representative values to various signal processing attacks considered in the watermarking context, this paper proposes a new watermarking scheme for audio signals. The watermark is embedded in the root-sum-square (RSS) of the two representative values of each signal block using the quantization technique. As a result, the RSS values are modified by scaling the signal according to the watermark bit sequence under the constraint of inaudibility relative to the human psycho-acoustic model. We also address and suggest solutions to the problem of synchronization and power scaling attacks. Experimental results show that the proposed scheme maintains high audio quality and robustness to various attacks including MP3 compression, re-sampling, jittering, and, DA/AD conversion.

  19. Plasma-Based Tunable High Frequency Power Limiter

    NASA Astrophysics Data System (ADS)

    Semnani, Abbas; Macheret, Sergey; Peroulis, Dimitrios

    2016-09-01

    Power limiters are often employed to protect sensitive receivers from being damaged or saturated by high-power incoming waves. Although wideband low-power limiters based on semiconductor technology are widely available, the options for high-power frequency-selective ones are very few. In this work, we study the application of a gas discharge tube (GDT) integrated in an evanescent-mode (EVA) cavity resonator as a plasma-based power limiter. Plasmas can inherently handle higher power in comparison with semiconductor diodes. Also, using a resonant structure provides the ability of having both lower threshold power and frequency-selective limiting, which are important if only a narrowband high-power signal is targeted. Higher input RF power results in stronger discharge in the GDT and consequently higher electron density which results in larger reflection. It is also possible to tune the threshold power by pre-ionizing the GDT with a DC bias voltage. As a proof of concept, a 2-GHz EVA resonator loaded by a 90-V GDT was fabricated and measured. With reasonable amount of insertion loss, the limiting threshold power was successfully tuned from 8.3 W to 590 mW when the external DC bias was varied from 0 to 80 V. The limiter performed well up to 100 W of maximum available input power.

  20. A new characterization of three-dimensional conductivity backbone above and below the percolation threshold

    NASA Astrophysics Data System (ADS)

    Skal, Asya S.

    1996-08-01

    A new definition of three-dimensional conductivity backbone, obtained from a distribution function of Joule heat and the Hall coefficient is introduced. The fractal dimension d fB = d - ( {g}/{v}) = 2.25 of conductivity backbone for both sides of the threshold is obtained from a critical exponent of the Hall coefficient g = 0.6. This allows one to construct, below the threshold, a new order parameter of metal-conductor transition—the two-component infinite conductivity back-bone and tested scaling relation, proposed by Alexander and Orbach [ J. Phys. Rev. Lett.43, 1982, L625] for both sides of a threshold.

  1. Mapping regions of Epstein-Barr virus (EBV) glycoprotein B (gB) important for fusion function with gH/gL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Plate, Aileen E.; Reimer, Jessica J.; Jardetzky, Theodore S.

    Glycoproteins gB and gH/gL are required for entry of Epstein-Barr virus (EBV) into cells, but the role of each glycoprotein and how they function together to mediate fusion is unclear. Analysis of the functional homology of gB from the closely related primate gammaherpesvirus, rhesus lymphocryptovirus (Rh-LCV), showed that EBV gB could not complement Rh gB due to a species-specific dependence between gB and gL. To map domains of gB required for this interaction, we constructed a panel of EBV/Rh gB chimeric proteins. Analysis showed that insertion of Rh gB from residues 456 to 807 restored fusion function of EBV gBmore » with Rh gH/gL, suggesting this region of gB is important for interaction with gH/gL. Split YFP bimolecular complementation (BiFC) provided evidence of an interaction between EBV gB and gH/gL. Together, our results suggest the importance of a gB-gH/gL interaction in EBV-mediated fusion with B cells requiring the region of EBV gB from 456 to 807.« less

  2. Threshold and non-threshold chemical carcinogens: A survey of the present regulatory landscape.

    PubMed

    Bevan, Ruth J; Harrison, Paul T C

    2017-08-01

    For the proper regulation of a carcinogenic material it is necessary to fully understand its mode of action, and in particular whether it demonstrates a threshold of effect. This paper explores our present understanding of carcinogenicity and the mechanisms underlying the carcinogenic response. The concepts of genotoxic and non-genotoxic and threshold and non-threshold carcinogens are fully described. We provide summary tables of the types of cancer considered to be associated with exposure to a number of carcinogens and the available evidence relating to whether carcinogenicity occurs through a threshold or non-threshold mechanism. In light of these observations we consider how different regulatory bodies approach the question of chemical carcinogenesis, looking in particular at the definitions and methodologies used to derive Occupational Exposure Levels (OELs) for carcinogens. We conclude that unless proper differentiation is made between threshold and non-threshold carcinogens, inappropriate risk management measures may be put in place - and lead also to difficulties in translating carcinogenicity research findings into appropriate health policies. We recommend that clear differentiation between threshold and non-threshold carcinogens should be made by all expert groups and regulatory bodies dealing with carcinogen classification and risk assessment. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Monolayer semiconductor nanocavity lasers with ultralow thresholds.

    PubMed

    Wu, Sanfeng; Buckley, Sonia; Schaibley, John R; Feng, Liefeng; Yan, Jiaqiang; Mandrus, David G; Hatami, Fariba; Yao, Wang; Vučković, Jelena; Majumdar, Arka; Xu, Xiaodong

    2015-04-02

    Engineering the electromagnetic environment of a nanometre-scale light emitter by use of a photonic cavity can significantly enhance its spontaneous emission rate, through cavity quantum electrodynamics in the Purcell regime. This effect can greatly reduce the lasing threshold of the emitter, providing a low-threshold laser system with small footprint, low power consumption and ultrafast modulation. An ultralow-threshold nanoscale laser has been successfully developed by embedding quantum dots into a photonic crystal cavity (PCC). However, several challenges impede the practical application of this architecture, including the random positions and compositional fluctuations of the dots, extreme difficulty in current injection, and lack of compatibility with electronic circuits. Here we report a new lasing strategy: an atomically thin crystalline semiconductor--that is, a tungsten diselenide monolayer--is non-destructively and deterministically introduced as a gain medium at the surface of a pre-fabricated PCC. A continuous-wave nanolaser operating in the visible regime is thereby achieved with an optical pumping threshold as low as 27 nanowatts at 130 kelvin, similar to the value achieved in quantum-dot PCC lasers. The key to the lasing action lies in the monolayer nature of the gain medium, which confines direct-gap excitons to within one nanometre of the PCC surface. The surface-gain geometry gives unprecedented accessibility and hence the ability to tailor gain properties via external controls such as electrostatic gating and current injection, enabling electrically pumped operation. Our scheme is scalable and compatible with integrated photonics for on-chip optical communication technologies.

  4. Monolayer semiconductor nanocavity lasers with ultralow thresholds

    NASA Astrophysics Data System (ADS)

    Wu, Sanfeng; Buckley, Sonia; Schaibley, John R.; Feng, Liefeng; Yan, Jiaqiang; Mandrus, David G.; Hatami, Fariba; Yao, Wang; Vučković, Jelena; Majumdar, Arka; Xu, Xiaodong

    2015-04-01

    Engineering the electromagnetic environment of a nanometre-scale light emitter by use of a photonic cavity can significantly enhance its spontaneous emission rate, through cavity quantum electrodynamics in the Purcell regime. This effect can greatly reduce the lasing threshold of the emitter, providing a low-threshold laser system with small footprint, low power consumption and ultrafast modulation. An ultralow-threshold nanoscale laser has been successfully developed by embedding quantum dots into a photonic crystal cavity (PCC). However, several challenges impede the practical application of this architecture, including the random positions and compositional fluctuations of the dots, extreme difficulty in current injection, and lack of compatibility with electronic circuits. Here we report a new lasing strategy: an atomically thin crystalline semiconductor--that is, a tungsten diselenide monolayer--is non-destructively and deterministically introduced as a gain medium at the surface of a pre-fabricated PCC. A continuous-wave nanolaser operating in the visible regime is thereby achieved with an optical pumping threshold as low as 27 nanowatts at 130 kelvin, similar to the value achieved in quantum-dot PCC lasers. The key to the lasing action lies in the monolayer nature of the gain medium, which confines direct-gap excitons to within one nanometre of the PCC surface. The surface-gain geometry gives unprecedented accessibility and hence the ability to tailor gain properties via external controls such as electrostatic gating and current injection, enabling electrically pumped operation. Our scheme is scalable and compatible with integrated photonics for on-chip optical communication technologies.

  5. A hybrid flower pollination algorithm based modified randomized location for multi-threshold medical image segmentation.

    PubMed

    Wang, Rui; Zhou, Yongquan; Zhao, Chengyan; Wu, Haizhou

    2015-01-01

    Multi-threshold image segmentation is a powerful image processing technique that is used for the preprocessing of pattern recognition and computer vision. However, traditional multilevel thresholding methods are computationally expensive because they involve exhaustively searching the optimal thresholds to optimize the objective functions. To overcome this drawback, this paper proposes a flower pollination algorithm with a randomized location modification. The proposed algorithm is used to find optimal threshold values for maximizing Otsu's objective functions with regard to eight medical grayscale images. When benchmarked against other state-of-the-art evolutionary algorithms, the new algorithm proves itself to be robust and effective through numerical experimental results including Otsu's objective values and standard deviations.

  6. Theoretical resolution of the H- resonance spectrum up to the n=4 threshold. I. States of 1Po, 1Do, and 1Fo symmetries

    NASA Astrophysics Data System (ADS)

    Bylicki, Mirosław; Nicolaides, Cleanthes A.

    2000-05-01

    We report on a theoretical approach to the calculation of wave functions, energies E, and widths Γ of high-lying resonances of H-, with application to the identification of 76 states of 1Po, 1Do, and 1Fo symmetries up to the n=4 threshold, with widths down to about 1×10-8-1×10-10 a.u., depending on symmetry and threshold. The overwhelming majority of these resonances have not been detected experimentally. Previous calculations by different methods allowed the identification of 35 of these states, with only very few cases having a level of accuracy comparable to the one of the present work. We suggest that the measurement of these resonances might become possible via two-step excitation mechanisms using ultrasensitive techniques capable of dealing with the problems of very small widths and preparation cross-sections. In this work, the 1D state at 10.872 eV above the H-1s2 1S ground state, already prepared and measured by electron scattering as well as by two-photon absorption, is considered as the stepping stone for the possible probing of resonances of 1Po, 1Do, and 1Fo symmetries via absorption of tunable radiation of high resolution. By classifying the results according to the Gailitis-Damburg model of dipole resonances (a product of a 1/r2-like potential) we find that there are unperturbed as well as perturbed series, in analogy with the Rydberg spectra of neutrals and positive ions (a product of a 1/r-like potential). For the former, the agreement with the Gailitis-Damburg predictions as to the relationship of the extent of the outer orbital and of the energies and widths of states is excellent. The perturbed series result from interchannel coupling and the remaining electron correlation. One of the effects is the existence of overlapping resonances. For example, for two 1Po states below the n=3 threshold there is degeneracy on the energy axis (E1=-0.0555763612 a.u. and E2=-0.0555763099 a.u.) but the widths differ (Γ1=1.14×10-4 eV and Γ2=5.45×10-6 e

  7. Intensity-duration threshold of rainfall-triggered debris flows in the Wenchuan Earthquake affected area, China

    NASA Astrophysics Data System (ADS)

    Guo, Xiaojun; Cui, Peng; Li, Yong; Ma, Li; Ge, Yonggang; Mahoney, William B.

    2016-01-01

    The Ms 8.0 Wenchuan Earthquake has greatly altered the rainfall threshold for debris flows in the affected areas. This study explores the local intensity-duration (I-D) relationship based on 252 post-earthquake debris flows. It was found that I = 5.25 D-0.76 accounts for more than 98% of the debris flow occurrences with rainfall duration between 1 and 135 h; therefore the curve defines the threshold for debris flows in the study area. This gives much lower thresholds than those proposed by the previous studies, suggesting that the earthquake has greatly decreased the thresholds in the past years. Moreover, the rainfall thresholds appear to increase annually in the period of 2008-2013, and present a logarithmic increasing tendency, indicating that the thresholds will recover in the future decades.

  8. Standardised method of determining vibratory perception thresholds for diagnosis and screening in neurological investigation.

    PubMed Central

    Goldberg, J M; Lindblom, U

    1979-01-01

    Vibration threshold determinations were made by means of an electromagnetic vibrator at three sites (carpal, tibial, and tarsal), which were primarily selected for examining patients with polyneuropathy. Because of the vast variation demonstrated for both vibrator output and tissue damping, the thresholds were expressed in terms of amplitude of stimulator movement measured by means of an accelerometer, instead of applied voltage which is commonly used. Statistical analysis revealed a higher power of discimination for amplitude measurements at all three stimulus sites. Digital read-out gave the best statistical result and was also most practical. Reference values obtained from 110 healthy males, 10 to 74 years of age, were highly correlated with age for both upper and lower extremities. The variance of the vibration perception threshold was less than that of the disappearance threshold, and determination of the perception threshold alone may be sufficient in most cases. PMID:501379

  9. Color difference threshold determination for acrylic denture base resins.

    PubMed

    Ren, Jiabao; Lin, Hong; Huang, Qingmei; Liang, Qifan; Zheng, Gang

    2015-01-01

    This study aimed to set evaluation indicators, i.e., perceptibility and acceptability color difference thresholds, of color stability for acrylic denture base resins for a spectrophotometric assessing method, which offered an alternative to the visual method described in ISO 20795-1:2013. A total of 291 disk specimens 50±1 mm in diameter and 0.5±0.1 mm thick were prepared (ISO 20795-1:2013) and processed through radiation tests in an accelerated aging chamber (ISO 7491:2000) for increasing times of 0 to 42 hours. Color alterations were measured with a spectrophotometer and evaluated using the CIE L*a*b* colorimetric system. Color differences were calculated through the CIEDE2000 color difference formula. Thirty-two dental professionals without color vision deficiencies completed perceptibility and acceptability assessments under controlled conditions in vitro. An S-curve fitting procedure was used to analyze the 50:50% perceptibility and acceptability thresholds. Furthermore, perceptibility and acceptability against the differences of the three color attributes, lightness, chroma, and hue, were also investigated. According to the S-curve fitting procedure, the 50:50% perceptibility threshold was 1.71ΔE00 (r(2)=0.88) and the 50:50% acceptability threshold was 4.00 ΔE00 (r(2)=0.89). Within the limitations of this study, 1.71/4.00 ΔE00 could be used as perceptibility/acceptability thresholds for acrylic denture base resins.

  10. Eccentric muscle damage has variable effects on motor unit recruitment thresholds and discharge patterns in elbow flexor muscles.

    PubMed

    Dartnall, Tamara J; Rogasch, Nigel C; Nordstrom, Michael A; Semmler, John G

    2009-07-01

    The purpose of this study was to determine the effect of eccentric muscle damage on recruitment threshold force and repetitive discharge properties of low-threshold motor units. Ten subjects performed four tasks involving isometric contraction of elbow flexors while electromyographic (EMG) data were recorded from human biceps brachii and brachialis muscles. Tasks were 1) maximum voluntary contraction (MVC); 2) constant-force contraction at various submaximal targets; 3) motor unit recruitment threshold task; and 4) minimum motor unit discharge rate task. These tasks were performed on three separate days before, immediately after, and 24 h after eccentric exercise of elbow flexor muscles. MVC force declined (42%) immediately after exercise and remained depressed (29%) 24 h later, indicative of muscle damage. Mean motor unit recruitment threshold for biceps brachii was 8.4+/-4.2% MVC, (n=34) before eccentric exercise, and was reduced by 41% (5.0+/-3.0% MVC, n=34) immediately after and by 39% (5.2+/-2.5% MVC, n=34) 24 h after exercise. No significant changes in motor unit recruitment threshold were observed in the brachialis muscle. However, for the minimum tonic discharge rate task, motor units in both muscles discharged 11% faster (10.8+/-2.0 vs. 9.7+/-1.7 Hz) immediately after (n=29) exercise compared with that before (n=32). The minimum discharge rate variability was greater in brachialis muscle immediately after exercise (13.8+/-3.1%) compared with that before (11.9+/-3.1%) and 24 h after exercise (11.7+/-2.4%). No significant changes in minimum discharge rate variability were observed in the biceps brachii motor units after exercise. These results indicate that muscle damage from eccentric exercise alters motor unit recruitment thresholds for >or=24 h, but the effect is not the same in the different elbow flexor muscles.

  11. Discrete diffraction managed solitons: Threshold phenomena and rapid decay for general nonlinearities

    NASA Astrophysics Data System (ADS)

    Choi, Mi-Ran; Hundertmark, Dirk; Lee, Young-Ran

    2017-10-01

    We prove a threshold phenomenon for the existence/non-existence of energy minimizing solitary solutions of the diffraction management equation for strictly positive and zero average diffraction. Our methods allow for a large class of nonlinearities; they are, for example, allowed to change sign, and the weakest possible condition, it only has to be locally integrable, on the local diffraction profile. The solutions are found as minimizers of a nonlinear and nonlocal variational problem which is translation invariant. There exists a critical threshold λcr such that minimizers for this variational problem exist if their power is bigger than λcr and no minimizers exist with power less than the critical threshold. We also give simple criteria for the finiteness and strict positivity of the critical threshold. Our proof of existence of minimizers is rather direct and avoids the use of Lions' concentration compactness argument. Furthermore, we give precise quantitative lower bounds on the exponential decay rate of the diffraction management solitons, which confirm the physical heuristic prediction for the asymptotic decay rate. Moreover, for ground state solutions, these bounds give a quantitative lower bound for the divergence of the exponential decay rate in the limit of vanishing average diffraction. For zero average diffraction, we prove quantitative bounds which show that the solitons decay much faster than exponentially. Our results considerably extend and strengthen the results of Hundertmark and Lee [J. Nonlinear Sci. 22, 1-38 (2012) and Commun. Math. Phys. 309(1), 1-21 (2012)].

  12. N -jettiness subtractions for g g →H at subleading power

    NASA Astrophysics Data System (ADS)

    Moult, Ian; Rothen, Lorena; Stewart, Iain W.; Tackmann, Frank J.; Zhu, Hua Xing

    2018-01-01

    N -jettiness subtractions provide a general approach for performing fully-differential next-to-next-to-leading order (NNLO) calculations. Since they are based on the physical resolution variable N -jettiness, TN , subleading power corrections in τ =TN/Q , with Q a hard interaction scale, can also be systematically computed. We study the structure of power corrections for 0-jettiness, T0, for the g g →H process. Using the soft-collinear effective theory we analytically compute the leading power corrections αsτ ln τ and αs2τ ln3τ (finding partial agreement with a previous result in the literature), and perform a detailed numerical study of the power corrections in the g g , g q , and q q ¯ channels. This includes a numerical extraction of the αsτ and αs2τ ln2τ corrections, and a study of the dependence on the T0 definition. Including such power suppressed logarithms significantly reduces the size of missing power corrections, and hence improves the numerical efficiency of the subtraction method. Having a more detailed understanding of the power corrections for both q q ¯ and g g initiated processes also provides insight into their universality, and hence their behavior in more complicated processes where they have not yet been analytically calculated.

  13. Aural Acoustic Stapedius-Muscle Reflex Threshold Procedures to Test Human Infants and Adults.

    PubMed

    Keefe, Douglas H; Feeney, M Patrick; Hunter, Lisa L; Fitzpatrick, Denis F

    2017-02-01

    Power-based procedures are described to measure acoustic stapedius-muscle reflex threshold and supra-threshold responses in human adult and infant ears at frequencies from 0.2 to 8 kHz. The stimulus set included five clicks in which four pulsed activators were placed between each pair of clicks, with each stimulus set separated from the next by 0.79 s to allow for reflex decay. Each click response was used to detect the presence of reflex effects across frequency that were elicited by a pulsed broadband-noise or tonal activator in the ipsilateral or contralateral test ear. Acoustic reflex shifts were quantified in terms of the difference in absorbed sound power between the initial baseline click and the later four clicks in each set. Acoustic reflex shifts were measured over a 40-dB range of pulsed activators, and the acoustic reflex threshold was objectively calculated using a maximum 10 likelihood procedure. To illustrate the principles underlying these new reflex tests, reflex shifts in absorbed sound power and absorbance are presented for data acquired in an adult ear with normal hearing and in two infant ears in the initial and follow-up newborn hearing screening exams, one with normal hearing and the other with a conductive hearing loss. The use of absorbed sound power was helpful in classifying an acoustic reflex shift as present or absent. The resulting reflex tests are in use in a large study of wideband clinical diagnosis and monitoring of middle-ear and cochlear function in infant and adult ears.

  14. Oxidation of RyR2 Has a Biphasic Effect on the Threshold for Store Overload-Induced Calcium Release.

    PubMed

    Waddell, Helen M M; Zhang, Joe Z; Hoeksema, Katie J; McLachlan, Julia J; McLay, Janet C; Jones, Peter P

    2016-06-07

    At the single-channel level, oxidation of the cardiac ryanodine receptor (RyR2) is known to activate and inhibit the channel depending on the level of oxidation. However, the mechanisms through which these changes alter the activity of RyR2 in a cellular setting are poorly understood. In this study, we determined the effect of oxidation on a common form of RyR2 regulation; store overload-induced Ca(2+) release (SOICR). We found that oxidation resulted in concentration and time-dependent changes in the activation threshold for SOICR. Low concentrations of the oxidant H2O2 resulted in a decrease in the threshold for SOICR, which led to an increase in SOICR events. However, higher concentrations of H2O2, or prolonged exposure, reversed these changes and led to an increase in the threshold for SOICR. This increase in the threshold for SOICR in most cells was to such an extent that it led to the complete inhibition of SOICR. Acute exposure to high concentrations of H2O2 led to an initial decrease and then increase in the threshold for SOICR. In the majority of cells the increased threshold could not be reversed by the application of the reducing agent dithiothreitol. Therefore, our data suggest that low levels of RyR2 oxidation increase the channel activity by decreasing the threshold for SOICR, whereas high levels of RyR2 oxidation irreversibly increase the threshold for SOICR leading to an inhibition of RyR2. Combined, this indicates that oxidation regulates RyR2 by the same mechanism as phosphorylation, methylxanthines, and mutations, via changes in the threshold for SOICR. Copyright © 2016 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  15. Vocabulary Acquisition in L2: Does CALL Really Help?

    ERIC Educational Resources Information Center

    Averianova, Irina

    2015-01-01

    Language competence in various communicative activities in L2 largely depends on the learners' size of vocabulary. The target vocabulary of adult L2 learners should be between 2,000 high frequency words (a critical threshold) and 10,000 word families (for comprehension of university texts). For a TOEIC test, the threshold is estimated to be…

  16. Superlinear threshold detectors in quantum cryptography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lydersen, Lars; Maroey, Oystein; Skaar, Johannes

    2011-09-15

    We introduce the concept of a superlinear threshold detector, a detector that has a higher probability to detect multiple photons if it receives them simultaneously rather than at separate times. Highly superlinear threshold detectors in quantum key distribution systems allow eavesdropping the full secret key without being revealed. Here, we generalize the detector control attack, and analyze how it performs against quantum key distribution systems with moderately superlinear detectors. We quantify the superlinearity in superconducting single-photon detectors based on earlier published data, and gated avalanche photodiode detectors based on our own measurements. The analysis shows that quantum key distribution systemsmore » using detector(s) of either type can be vulnerable to eavesdropping. The avalanche photodiode detector becomes superlinear toward the end of the gate. For systems expecting substantial loss, or for systems not monitoring loss, this would allow eavesdropping using trigger pulses containing less than 120 photons per pulse. Such an attack would be virtually impossible to catch with an optical power meter at the receiver entrance.« less

  17. Design concepts of high power bipolar rechargeable lithium battery

    NASA Technical Reports Server (NTRS)

    Shen, David H.; Halpert, Gerald

    1993-01-01

    The present study shows that current bipolar Li/TiS2 batteries using a 0.38 mm thick TiS2 bipolar plate can yield moderate specific power and also high specific energy battery. The computer design studies project that a 100 V, 10 A h bipolar Li/TiS2 battery can achieve 150 W h/kg, 210 W h/l, and 150 W/kg. The unoptimized experimental bipolar Li/TiS2 batteries (3 cells, 90 mA h) exhibited 47 W h/kg, 90 W h/l, and 140 W/kg. Preliminary results on the cycleability of the bipolar batteries are demonstrated. The results also show that enhanced rate capability can be achieved by using pulse discharge and longer rest period between pulses.

  18. Targeting myeloid differentiation protein 2 by the new chalcone L2H21 protects LPS-induced acute lung injury.

    PubMed

    Zhang, Yali; Xu, Tingting; Wu, Beibei; Chen, Hongjin; Pan, Zheer; Huang, Yi; Mei, Liqin; Dai, Yuanrong; Liu, Xing; Shan, Xiaoou; Liang, Guang

    2017-04-01

    Acute inflammatory diseases are the leading causes of mortality in intensive care units. Myeloid differentiation 2 (MD-2) is required for recognizing lipopolysaccharide (LPS) by toll-like receptor 4 (TLR4), and represents an attractive therapeutic target for LPS-induced inflammatory diseases. In this study, we report a chalcone derivative, L2H21, as a new MD2 inhibitor, which could inhibit LPS-induced inflammation both in vitro and in vivo. We identify that L2H21 as a direct inhibitor of MD-2 by binding to Arg 90 and Tyr 102 residues in MD-2 hydrophobic pocket using a series of biochemical experiments, including surface plasmon response, molecular docking and amino acid mutation. L2H21 dose dependently inhibited LPS-induced inflammatory cytokine expression in primary macrophages. In mice with LPS intratracheal instillation, L2H21 significantly decreased LPS-induced pulmonary oedema, pathological changes in lung tissue, protein concentration increase in bronchoalveolar lavage fluid, inflammatory cells infiltration and inflammatory gene expression, accompanied with the decrease in pulmonary TLR4/MD-2 complex. Meanwhile, administration with L2H21 protects mice from LPS-induced mortality at a degree of 100%. Taken together, this study identifies a new MD2 inhibitor L2H21 as a promising candidate for the treatment of acute lung injury (ALI) and sepsis, and validates that inhibition of MD-2 is a potential therapeutic strategy for ALI. © 2016 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.

  19. Evaluation of three different histamine concentrations in intradermal testing of normal cats and attempted determination of 'irritant' threshold concentrations for 48 allergens.

    PubMed

    Austel, Michaela; Hensel, Patrick; Jackson, Dawn; Vidyashankar, Anand; Zhao, Ying; Medleau, Linda

    2006-06-01

    The purpose of this study was to determine the optimal histamine concentration and 'irritant' allergen threshold concentrations in intradermal testing (IDT) in normal cats. Thirty healthy cats were tested with three different histamine concentrations and four different concentrations of each allergen. The optimal histamine concentration was determined to be 1: 50,000 w/v (0.05 mg mL(-1)). Using this histamine concentration, the 'irritant' threshold concentration for most allergens was above the highest concentrations tested (4,000 PNU mL(-1) for 41 allergens and 700 PNU mL(-1) for human dander). The 'irritant' threshold concentration for flea antigen was determined to be 1:750 w/v. More than 10% of the tested cats showed positive reactions to Dermatophagoides farinae, Dermatophagoides pteronyssinus, housefly, mosquito and moth at every allergen concentration, which suggests that the 'irritant' threshold concentration for these allergens is below 1,000 PNU mL(-1), the lowest allergen concentration tested. Our results confirm previous studies in indicating that allergen and histamine concentrations used in feline IDT may need to be revised.

  20. Numerical investigation of the inertial cavitation threshold under multi-frequency ultrasound.

    PubMed

    Suo, Dingjie; Govind, Bala; Zhang, Shengqi; Jing, Yun

    2018-03-01

    Through the introduction of multi-frequency sonication in High Intensity Focused Ultrasound (HIFU), enhancement of efficiency has been noted in several applications including thrombolysis, tissue ablation, sonochemistry, and sonoluminescence. One key experimental observation is that multi-frequency ultrasound can help lower the inertial cavitation threshold, thereby improving the power efficiency. However, this has not been well corroborated by the theory. In this paper, a numerical investigation on the inertial cavitation threshold of microbubbles (MBs) under multi-frequency ultrasound irradiation is conducted. The relationships between the cavitation threshold and MB size at various frequencies and in different media are investigated. The results of single-, dual and triple frequency sonication show reduced inertial cavitation thresholds by introducing additional frequencies which is consistent with previous experimental work. In addition, no significant difference is observed between dual frequency sonication with various frequency differences. This study, not only reaffirms the benefit of using multi-frequency ultrasound for various applications, but also provides a possible route for optimizing ultrasound excitations for initiating inertial cavitation. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Xylary pH and Reduction Potential Levels of Iron-stressed Silver Maple (Acer saccharinum L.) 1

    PubMed Central

    Morris, Robert L.; Swanson, Bert T.

    1980-01-01

    Xylary fluid pH and reduction potentials were measured on silver maple (Acer saccharinum L.) grown under Fe and pH stress. Although pH and reduction potential (millivolt/59.2) varied significantly in the nutrient solution, xylary pH and reduction potential remained constant. It was concluded that changes in the pH and reduction potential in the xylary fluid of silver maple are not responsible for iron chlorosis. PMID:16661196

  2. PD-L1, B7-H3, and PD-1 expression in immunocompetent vs. immunosuppressed patients with cutaneous squamous cell carcinoma.

    PubMed

    Varki, Vinod; Ioffe, Olga B; Bentzen, Soren M; Heath, Jon; Cellini, Ashley; Feliciano, Josephine; Zandberg, Dan P

    2018-05-01

    To characterize the expression of co-signaling molecules PD-L1, PD-1, and B7-H3 in cutaneous squamous cell carcinoma (cSCC) by immune status. We retrospectively analyzed 66 cases of cSCC treated with surgical resection from 2012 to 2015. Immunostained tumor sections were analyzed for percent of tumor cells expressing PD-L1 (Tum-PD-L1%), B7-H3 (Tum-B7-H3%), density of peri and intratumoral CD8 T cells (CD8 density), proportion of CD8 T cells expressing PD-1 (CD8-PD-1%) and of tumor-infiltrating immune cells (TII) expressing PD-L1 (TII-PD-L1%). Of 66 cases, 42 were immunocompetent, 24 immunosuppressed (13 organ transplant, 8 HIV+, 3 other). Defining positive expression at > 5%, 26% of tumors were positive for PD-L1, 85% for B7-H3, 80% had CD8 T cells that expressed PD-1 and 55% had TII that expressed PD-L1. Tum-B7-H3% was significantly higher (median 60 vs. 28%, p = 0.025) in immunocompetent vs. immunosuppressed patients, including when factoring in cause of immunosuppression. No significant difference in Tum-PD-L1%, TII-PD-L1%, CD8 density, or CD8-PD-1% was observed. Tumors from HIV+ patients lacked PD-L1 expression, and had lower B7-H3% (median 2.5 vs. 60%, p = 0.007), and higher CD8 density (median 75% vs. 40%, p = 0.04) compared to immunocompetent patients. Higher tumor grade (R s  = 0.34, p = 0.006) and LVI (R s  = 0.61, p < 0.001) were both associated with higher Tum-PD-L1%. cSCC showed expression of PD-L1 on tumor in 26% of cases, and high tumor B7-H3 expression (85%) and PD-1 expression on CD8 TILs (80%). Tumor B7-H3 expression was significantly higher in immunocompetent vs. immunosuppressed patients, largely driven by very low expression in HIV+ patients.

  3. Threshold magnitudes for a multichannel correlation detector in background seismicity

    DOE PAGES

    Carmichael, Joshua D.; Hartse, Hans

    2016-04-01

    Colocated explosive sources often produce correlated seismic waveforms. Multichannel correlation detectors identify these signals by scanning template waveforms recorded from known reference events against "target" data to find similar waveforms. This screening problem is challenged at thresholds required to monitor smaller explosions, often because non-target signals falsely trigger such detectors. Therefore, it is generally unclear what thresholds will reliably identify a target explosion while screening non-target background seismicity. Here, we estimate threshold magnitudes for hypothetical explosions located at the North Korean nuclear test site over six months of 2010, by processing International Monitoring System (IMS) array data with a multichannelmore » waveform correlation detector. Our method (1) accounts for low amplitude background seismicity that falsely triggers correlation detectors but is unidentifiable with conventional power beams, (2) adapts to diurnally variable noise levels and (3) uses source-receiver reciprocity concepts to estimate thresholds for explosions spatially separated from the template source. Furthermore, we find that underground explosions with body wave magnitudes m b = 1.66 are detectable at the IMS array USRK with probability 0.99, when using template waveforms consisting only of P -waves, without false alarms. We conservatively find that these thresholds also increase by up to a magnitude unit for sources located 4 km or more from the Feb.12, 2013 announced nuclear test.« less

  4. Effects of pump recycling technique on stimulated Brillouin scattering threshold: a theoretical model.

    PubMed

    Al-Asadi, H A; Al-Mansoori, M H; Ajiya, M; Hitam, S; Saripan, M I; Mahdi, M A

    2010-10-11

    We develop a theoretical model that can be used to predict stimulated Brillouin scattering (SBS) threshold in optical fibers that arises through the effect of Brillouin pump recycling technique. Obtained simulation results from our model are in close agreement with our experimental results. The developed model utilizes single mode optical fiber of different lengths as the Brillouin gain media. For 5-km long single mode fiber, the calculated threshold power for SBS is about 16 mW for conventional technique. This value is reduced to about 8 mW when the residual Brillouin pump is recycled at the end of the fiber. The decrement of SBS threshold is due to longer interaction lengths between Brillouin pump and Stokes wave.

  5. Transient threshold shift after gunshot noise exposure.

    PubMed

    Saedi, B; Ghasemi, M; Motiee, M; Mojtahed, M; Safavi, A

    2013-01-01

    Many people, such as soldiers, are routinely exposed to gunshot noise during target practice. It is suspected that this high-intensity noise may affect audition through repeated Transient Threshold Shifts (TTS); it can also mechanically alter auditory components such as waves. This study investigates the scope of gunshot noise from the AK-47 rifle (Kalashnikov) and the impact on the shooters' audition. Forty soldiers (80 ears) were recruited in this study. They were all young and being exposed to gunshot noise for the first time. Gunshot characteristics were measured before exposure. The soldiers underwent auditory evaluation with Pure Tone Audiometry (PTA) and Oto-Acoustic Emission (OAE) once before exposure and immediately (less than one hour) after exposure. The AK-47 gunshot noise pressure level varied between L(AIm) = 73.7 dBA to L(AIm) = 111.4 dBA. Fourteen participants had subclinical hearing impairment in their pre-exposure evaluation; this number increased to 16 after the exposure. Six months post-exposure and later, the number of cases with impairment had fallen to eight (improvement in 50%). Both pre- and post-exposure OAE results were within normal values, while PTA results indicated a significant threshold alteration only at 6 kHz. The results of this study confirm that exposure to gunshot noise with no ear protection can represent a significant hazard for auditory function, especially at higher frequencies.

  6. Evidence for thermally assisted threshold switching behavior in nanoscale phase-change memory cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Le Gallo, Manuel; Athmanathan, Aravinthan; Krebs, Daniel

    2016-01-14

    In spite of decades of research, the details of electrical transport in phase-change materials are still debated. In particular, the so-called threshold switching phenomenon that allows the current density to increase steeply when a sufficiently high voltage is applied is still not well understood, even though there is wide consensus that threshold switching is solely of electronic origin. However, the high thermal efficiency and fast thermal dynamics associated with nanoscale phase-change memory (PCM) devices motivate us to reassess a thermally assisted threshold switching mechanism, at least in these devices. The time/temperature dependence of the threshold switching voltage and current inmore » doped Ge{sub 2}Sb{sub 2}Te{sub 5} nanoscale PCM cells was measured over 6 decades in time at temperatures ranging from 40 °C to 160 °C. We observe a nearly constant threshold switching power across this wide range of operating conditions. We also measured the transient dynamics associated with threshold switching as a function of the applied voltage. By using a field- and temperature-dependent description of the electrical transport combined with a thermal feedback, quantitative agreement with experimental data of the threshold switching dynamics was obtained using realistic physical parameters.« less

  7. Microplastic Effect Thresholds for Freshwater Benthic Macroinvertebrates

    PubMed Central

    2018-01-01

    Now that microplastics have been detected in lakes, rivers, and estuaries all over the globe, evaluating their effects on biota has become an urgent research priority. This is the first study that aims at determining the effect thresholds for a battery of six freshwater benthic macroinvertebrates with different species traits, using a wide range of microplastic concentrations. Standardized 28 days single species bioassays were performed under environmentally relevant exposure conditions using polystyrene microplastics (20–500 μm) mixed with sediment at concentrations ranging from 0 to 40% sediment dry weight (dw). Microplastics caused no effects on the survival of Gammarus pulex, Hyalella azteca, Asellus aquaticus, Sphaerium corneum, and Tubifex spp. and no effects were found on the reproduction of Lumbriculus variegatus. No significant differences in growth were found for H. azteca, A. aquaticus, S. corneum, L. variegatus, and Tubifex spp. However, G. pulex showed a significant reduction in growth (EC10 = 1.07% sediment dw) and microplastic uptake was proportional with microplastic concentrations in sediment. These results indicate that although the risks of environmentally realistic concentrations of microplastics may be low, they still may affect the biodiversity and the functioning of aquatic communities which after all also depend on the sensitive species. PMID:29337537

  8. Microplastic Effect Thresholds for Freshwater Benthic Macroinvertebrates.

    PubMed

    Redondo-Hasselerharm, Paula E; Falahudin, Dede; Peeters, Edwin T H M; Koelmans, Albert A

    2018-02-20

    Now that microplastics have been detected in lakes, rivers, and estuaries all over the globe, evaluating their effects on biota has become an urgent research priority. This is the first study that aims at determining the effect thresholds for a battery of six freshwater benthic macroinvertebrates with different species traits, using a wide range of microplastic concentrations. Standardized 28 days single species bioassays were performed under environmentally relevant exposure conditions using polystyrene microplastics (20-500 μm) mixed with sediment at concentrations ranging from 0 to 40% sediment dry weight (dw). Microplastics caused no effects on the survival of Gammarus pulex, Hyalella azteca, Asellus aquaticus, Sphaerium corneum, and Tubifex spp. and no effects were found on the reproduction of Lumbriculus variegatus. No significant differences in growth were found for H. azteca, A. aquaticus, S. corneum, L. variegatus, and Tubifex spp. However, G. pulex showed a significant reduction in growth (EC 10 = 1.07% sediment dw) and microplastic uptake was proportional with microplastic concentrations in sediment. These results indicate that although the risks of environmentally realistic concentrations of microplastics may be low, they still may affect the biodiversity and the functioning of aquatic communities which after all also depend on the sensitive species.

  9. Gas-phase hydrogen atom abstraction reactions of S- with H2, CH4, and C2H6

    NASA Astrophysics Data System (ADS)

    Angel, Laurence A.; Dogbevia, Moses K.; Rempala, Katarzyna M.; Ervin, Kent M.

    2003-11-01

    Reaction cross sections, product axial velocity distributions, and potential energy surfaces are presented for the hydrogen atom abstraction reactions S-+RH→R+HS- (R=H, CH3, C2H5) as a function of collision energy. The observed threshold energy, E0, for S-+H2→H+HS- agrees with the reaction endothermicity, ΔrH0. At low collision energies, the H+HS- products exhibit symmetric, low-recoil-velocity scattering, consistent with statistical reaction behavior. The S-+CH4→CH3+HS- and S-+C2H6→C2H5+HS reactions, in contrast, show large excess threshold energies when compared to ΔrH0. The excess energies are partly explained by a potential energy barrier separating products from reactants. However, additional dynamical constraints must account for more than half of the excess threshold energy. The observed behavior seems to be general for collisional activation of anion-molecule reactions that proceed through a tight, late transition state. For RH=CH4 and C2H6, the HS- velocity distributions show anisotropic backward scattering at low collision energies indicating small impact parameters and a direct rebound reaction mechanism. At higher collision energies, there is a transition to HS- forward scattering and high velocities consistent with grazing collisions and a stripping mechanism.

  10. Dantrolene Reduces the Threshold and Gain for Shivering

    PubMed Central

    Lin, Chun-Ming; Neeru, Sharma; Doufas, Anthony G.; Liem, Edwin; Shah, Yunus Muneer; Wadhwa, Anupama; Lenhardt, Rainer; Bjorksten, Andrew; Kurz, Andrea

    2005-01-01

    Dantrolene is used for treatment of life-threatening hyperthermia, yet its thermoregulatory effects are unknown. We tested the hypothesis that dantrolene reduces the threshold (triggering core temperature) and gain (incremental increase) of shivering. With IRB approval and informed consent, healthy volunteers were evaluated on two random days: control and dantrolene (≈2.5 mg/kg plus a continuous infusion). In study 1, 9 men were warmed until sweating was provoked and then cooled until arterio-venous shunt constriction and shivering occurred. Sweating was quantified on the chest using a ventilated capsule. Absolute right middle fingertip blood flow was quantified using venous-occlusion volume plethysmography. A sustained increase in oxygen consumption identified the shivering threshold. In study 2, 9 men were given cold Ringer's solution IV to reduce core temperature ≈2°C/h. Cooling was stopped when shivering intensity no longer increased with further core cooling. The gain of shivering was the slope of oxygen consumption vs. core temperature regression. In Study 1, sweating and vasoconstriction thresholds were similar on both days. In contrast, shivering threshold decreased 0.3±0.3°C, P=0.004, on the dantrolene day. In Study 2, dantrolene decreased the shivering threshold from 36.7±0.2 to 36.3±0.3°C, P=0.01 and systemic gain from 353±144 to 211±93 ml·min−1·°C−1, P=0.02. Thus, dantrolene substantially decreased the gain of shivering, but produced little central thermoregulatory inhibition. PMID:15105208

  11. Uncertainties in the Modelled CO2 Threshold for Antarctic Glaciation

    NASA Technical Reports Server (NTRS)

    Gasson, E.; Lunt, D. J.; DeConto, R.; Goldner, A.; Heinemann, M.; Huber, M.; LeGrande, A. N.; Pollard, D.; Sagoo, N.; Siddall, M.; hide

    2014-01-01

    frequently cited atmospheric CO2 threshold for the onset of Antarctic glaciation of approximately780 parts per million by volume is based on the study of DeConto and Pollard (2003) using an ice sheet model and the GENESIS climate model. Proxy records suggest that atmospheric CO2 concentrations passed through this threshold across the Eocene-Oligocene transition approximately 34 million years. However, atmospheric CO2 concentrations may have been close to this threshold earlier than this transition, which is used by some to suggest the possibility of Antarctic ice sheets during the Eocene. Here we investigate the climate model dependency of the threshold for Antarctic glaciation by performing offline ice sheet model simulations using the climate from 7 different climate models with Eocene boundary conditions (HadCM3L, CCSM3, CESM1.0, GENESIS, FAMOUS, ECHAM5 and GISS_ER). These climate simulations are sourced from a number of independent studies, and as such the boundary conditions, which are poorly constrained during the Eocene, are not identical between simulations. The results of this study suggest that the atmospheric CO2 threshold for Antarctic glaciation is highly dependent on the climate model used and the climate model configuration. A large discrepancy between the climate model and ice sheet model grids for some simulations leads to a strong sensitivity to the lapse rate parameter.

  12. A Near-Threshold Shape Resonance in the Valence-Shell Photoabsorption of Linear Alkynes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacovella, U.; Holland, D. M. P.; Boyé-Péronne, S.

    2015-12-17

    The room-temperature photoabsorption spectra of a number of linear alkynes with internal triple bonds (e.g., 2-butyne, 2-pentyne, and 2- and 3-hexyne) show similar resonances just above the lowest ionization threshold of the neutral molecules. These features result in a substantial enhancement of the photoabsorption cross sections relative to the cross sections of alkynes with terminal triple bonds (e.g., propyne, 1-butyne, 1-pentyne,...). Based on earlier work on 2-butyne [Xu et al., J. Chem. Phys. 2012, 136, 154303], these features are assigned to excitation from the neutral highest occupied molecular orbital (HOMO) to a shape resonance with g (l = 4) charactermore » and approximate pi symmetry. This generic behavior results from the similarity of the HOMOs in all internal alkynes, as well as the similarity of the corresponding g pi virtual orbital in the continuum. Theoretical calculations of the absorption spectrum above the ionization threshold for the 2- and 3-alkynes show the presence of a shape resonance when the coupling between the two degenerate or nearly degenerate pi channels is included, with a dominant contribution from l = 4. These calculations thus confirm the qualitative arguments for the importance of the l = 4 continuum near threshold for internal alkynes, which should also apply to other linear internal alkynes and alkynyl radicals. The 1-alkynes do not have such high partial waves present in the shape resonance. The lower l partial waves in these systems are consistent with the broader features observed in the corresponding spectra.« less

  13. Insights into the distribution of water in a self-humidifying H2/O2 proton-exchange membrane fuel cell using 1H NMR microscopy.

    PubMed

    Feindel, Kirk W; Bergens, Steven H; Wasylishen, Roderick E

    2006-11-01

    Proton ((1)H) NMR microscopy is used to investigate in-situ the distribution of water throughout a self-humidifying proton-exchange membrane fuel cell, PEMFC, operating at ambient temperature and pressure on dry H(2)(g) and O(2)(g). The results provide the first experimental images of the in-plane distribution of water within the PEM of a membrane electrode assembly in an operating fuel cell. The effect of gas flow configuration on the distribution of water in the PEM and cathode flow field is investigated, revealing that the counter-flow configurations yield a more uniform distribution of water throughout the PEM. The maximum power output from the PEMFC, while operating under conditions of constant external load, occurs when H(2)O(l) is first visible in the (1)H NMR image of the cathode flow field, and subsequently declines as this H(2)O(l) continues to accumulate. The (1)H NMR microscopy experiments are in qualitative agreement with predictions from several theoretical modeling studies (e.g., Pasaogullari, U.; Wang, C. Y. J. Electrochem. Soc. 2005, 152, A380-A390), suggesting that combined theoretical and experimental approaches will constitute a powerful tool for PEMFC design, diagnosis, and optimization.

  14. Differential HIF and NOS responses to acute anemia: defining organ-specific hemoglobin thresholds for tissue hypoxia.

    PubMed

    Tsui, Albert K Y; Marsden, Philip A; Mazer, C David; Sled, John G; Lee, Keith M; Henkelman, R Mark; Cahill, Lindsay S; Zhou, Yu-Qing; Chan, Neville; Liu, Elaine; Hare, Gregory M T

    2014-07-01

    Tissue hypoxia likely contributes to anemia-induced organ injury and mortality. Severe anemia activates hypoxia-inducible factor (HIF) signaling by hypoxic- and neuronal nitric oxide (NO) synthase- (nNOS) dependent mechanisms. However, organ-specific hemoglobin (Hb) thresholds for increased HIF expression have not been defined. To assess organ-specific Hb thresholds for tissue hypoxia, HIF-α (oxygen-dependent degradation domain, ODD) luciferase mice were hemodiluted to mild, moderate, or severe anemia corresponding to Hb levels of 90, 70, and 50 g/l, respectively. HIF luciferase reporter activity, HIF protein, and HIF-dependent RNA levels were assessed. In the brain, HIF-1α was paradoxically decreased at mild anemia, returned to baseline at moderate anemia, and then increased at severe anemia. Brain HIF-2α remained unchanged at all Hb levels. Both kidney HIF-1α and HIF-2α increased earlier (Hb ∼70-90 g/l) in response to anemia. Liver also exhibited an early HIF-α response. Carotid blood flow was increased early (Hb ∼70, g/l), but renal blood flow remained relatively constant, only increased at Hb of 50 g/l. Anemia increased nNOS (brain and kidney) and endothelia NOS (eNOS) (kidney) levels. Whereas anemia-induced increases in brain HIFα were nNOS-dependent, our current data demonstrate that increased renal HIFα was nNOS independent. HIF-dependent RNA levels increased linearly (∼10-fold) in the brain. However, renal HIF-RNA responses (MCT4, EPO) increased exponentially (∼100-fold). Plasma EPO levels increased near Hb threshold of 90 g/l, suggesting that the EPO response is sensitive. Collectively, these observations suggest that each organ expresses a different threshold for cellular HIF/NOS hypoxia responses. This knowledge may help define the mechanism(s) by which the brain and kidney maintain oxygen homeostasis during anemia. Copyright © 2014 the American Physiological Society.

  15. Three-dimensional kinematic analysis and power output of elite flat-water kayakers.

    PubMed

    Bjerkefors, Anna; Tarassova, Olga; Rosén, Johanna S; Zakaria, Pascal; Arndt, Anton

    2017-09-20

    The purpose was to examine power output and three-dimensional (3D) kinematic variables in the upper limbs, lower limbs and trunk in elite flat-water kayakers during kayak ergometer paddling. An additional purpose was to analyse possible changes in kinematics with increased intensity and differences between body sides. Six male and four female international level flat-water kayakers participated. Kinematic and kinetic data were collected during three tasks; low (Int L ), high (Int H ) and maximal (Int M ) intensities. No differences were observed in any joint angles between body sides, except for shoulder abduction. Significantly greater range of motion (RoM) values were observed for Int H compared to Int L and for Int M compared to Int L in trunk and pelvis rotation, and in hip, knee and ankle flexion. The mean maximal power output was 610 ± 65 and 359 ± 33 W for the male and female athletes, respectively. The stroke frequencies were significantly different between all intensities (Int L 59.3 ± 6.3; Int H 108.0 ± 6.8; Int M 141.7 ± 18.4 strokes/min). The results showed that after a certain intensity level, the power output must be increased by other factors than increasing the joint angular RoM. This information may assist coaches and athletes to understand the relationship between the movement of the kayaker and the paddling power output.

  16. Computational repositioning of ethno medicine elucidated gB-gH-gL complex as novel anti herpes drug target

    PubMed Central

    2013-01-01

    Background Herpes viruses are important human pathogens that can cause mild to severe lifelong infections with high morbidity. They remain latent in the host cells and can cause recurrent infections that might prove fatal. These viruses are known to infect the host cells by causing the fusion of viral and host cell membrane proteins. Fusion is achieved with the help of conserved fusion machinery components, glycoproteins gB, heterodimer gH-gL complex along with other non-conserved components. Whereas, another important glycoprotein gD without which viral entry to the cell is not possible, acts as a co-activator for the gB-gH-gL complex formation. Thus, this complex formation interface is the most promising drug target for the development of novel anti-herpes drug candidates. In the present study, we propose a model for binding of gH-gL to gB glycoprotein leading from pre to post conformational changes during gB-gH-gL complex formation and reported the key residues involved in this binding activity along with possible binding site locations. To validate the drug targetability of our proposed binding site, we have repositioned some of the most promising in vitro, in vivo validated anti-herpes molecules onto the proposed binding site of gH-gL complex in a computational approach. Methods Hex 6.3 standalone software was used for protein-protein docking studies. Arguslab 4.0.1 and Accelrys® Discovery Studio 3.1 Visualizer softwares were used for semi-flexible docking studies and visualizing the interactions respectively. Protein receptors and ethno compounds were retrieved from Protein Data Bank (PDB) and Pubchem databases respectively. Lipinski’s Filter, Osiris Property Explorer and Lazar online servers were used to check the pharmaceutical fidelity of the drug candidates. Results Through protein-protein docking studies, it was identified that the amino acid residues VAL342, GLU347, SER349, TYR355, SER388, ASN395, HIS398 and ALA387 of gH-gL complex play an active

  17. Effects of whole body vibration on motor unit recruitment and threshold

    PubMed Central

    Woledge, Roger C.; Martin, Finbarr C.; Newham, Di J.

    2012-01-01

    Whole body vibration (WBV) has been suggested to elicit reflex muscle contractions but this has never been verified. We recorded from 32 single motor units (MU) in the vastus lateralis of 7 healthy subjects (34 ± 15.4 yr) during five 1-min bouts of WBV (30 Hz, 3 mm peak to peak), and the vibration waveform was also recorded. Recruitment thresholds were recorded from 38 MUs before and after WBV. The phase angle distribution of all MUs during WBV was nonuniform (P < 0.001) and displayed a prominent peak phase angle of firing. There was a strong linear relationship (r = −0.68, P < 0.001) between the change in recruitment threshold after WBV and average recruitment threshold; the lowest threshold MUs increased recruitment threshold (P = 0.008) while reductions were observed in the higher threshold units (P = 0.031). We investigated one possible cause of changed thresholds. Presynaptic inhibition in the soleus was measured in 8 healthy subjects (29 ± 4.6 yr). A total of 30 H-reflexes (stimulation intensity 30% Mmax) were recorded before and after WBV: 15 conditioned by prior stimulation (60 ms) of the antagonist and 15 unconditioned. There were no significant changes in the relationship between the conditioned and unconditioned responses. The consistent phase angle at which each MU fired during WBV indicates the presence of reflex muscle activity similar to the tonic vibration reflex. The varying response in high- and low-threshold MUs may be due to the different contributions of the mono- and polysynaptic pathways but not presynaptic inhibition. PMID:22096119

  18. Effects of whole body vibration on motor unit recruitment and threshold.

    PubMed

    Pollock, Ross D; Woledge, Roger C; Martin, Finbarr C; Newham, Di J

    2012-02-01

    Whole body vibration (WBV) has been suggested to elicit reflex muscle contractions but this has never been verified. We recorded from 32 single motor units (MU) in the vastus lateralis of 7 healthy subjects (34 ± 15.4 yr) during five 1-min bouts of WBV (30 Hz, 3 mm peak to peak), and the vibration waveform was also recorded. Recruitment thresholds were recorded from 38 MUs before and after WBV. The phase angle distribution of all MUs during WBV was nonuniform (P < 0.001) and displayed a prominent peak phase angle of firing. There was a strong linear relationship (r = -0.68, P < 0.001) between the change in recruitment threshold after WBV and average recruitment threshold; the lowest threshold MUs increased recruitment threshold (P = 0.008) while reductions were observed in the higher threshold units (P = 0.031). We investigated one possible cause of changed thresholds. Presynaptic inhibition in the soleus was measured in 8 healthy subjects (29 ± 4.6 yr). A total of 30 H-reflexes (stimulation intensity 30% Mmax) were recorded before and after WBV: 15 conditioned by prior stimulation (60 ms) of the antagonist and 15 unconditioned. There were no significant changes in the relationship between the conditioned and unconditioned responses. The consistent phase angle at which each MU fired during WBV indicates the presence of reflex muscle activity similar to the tonic vibration reflex. The varying response in high- and low-threshold MUs may be due to the different contributions of the mono- and polysynaptic pathways but not presynaptic inhibition.

  19. Variable percolation threshold of composites with fiber fillers under compression

    NASA Astrophysics Data System (ADS)

    Lin, Chuan; Wang, Hongtao; Yang, Wei

    2010-07-01

    The piezoresistant effect in conducting fiber-filled composites has been studied by a continuum percolation model. Simulation was performed by a Monte Carlo method that took into account both the deformation-induced fiber bending and rotation. The percolation threshold was found to rise with the compression strain, which explains the observed positive piezoresistive coefficients in such composites. The simulations unveiled the effect of the microstructure evolution during deformation. The fibers are found to align perpendicularly to the compression direction. As the fiber is bended, the effective length in making a conductive network is shortened. Both effects contribute to a larger percolation threshold and imply a positive piezoresistive coefficient according the universal power law.

  20. The immediate effects of sigmoid colon manipulation on pressure pain thresholds in the lumbar spine.

    PubMed

    McSweeney, Terence P; Thomson, Oliver P; Johnston, Ross

    2012-10-01

    Visceral manual therapy is increasingly used by UK osteopaths and manual therapists, but there is a paucity of research investigating its underlying mechanisms, and in particular in relation to hypoalgesia. The aim of this study was to investigate the immediate effects of osteopathic visceral mobilisation on pressure pain thresholds. A single-blinded, randomised, within subjects, repeated measures design was conducted on 15 asymptomatic subjects. Pressure pain thresholds were measured at the L1 paraspinal musculature and 1st dorsal interossei before and after osteopathic visceral mobilisation of the sigmoid colon. The results demonstrated a statistically significant improvement in pressure pain thresholds immediately after the intervention (P<0.001). This effect was not observed to be systemic, affecting only the L1 paraspinal musculature. This novel study provides new experimental evidence that visceral manual therapy can produce immediate hypoalgesia in somatic structures segmentally related to the organ being mobilised, in asymptomatic subjects. Copyright © 2012. Published by Elsevier Ltd.

  1. Metabolic power demands of rugby league match play.

    PubMed

    Kempton, Tom; Sirotic, Anita Claire; Rampinini, Ermanno; Coutts, Aaron James

    2015-01-01

    To describe the metabolic demands of rugby league match play for positional groups and compare match distances obtained from high-speed-running classifications with those derived from high metabolic power. Global positioning system (GPS) data were collected from 25 players from a team competing in the National Rugby League competition over 39 matches. Players were classified into positional groups (adjustables, outside backs, hit-up forwards, and wide-running forwards). The GPS devices provided instantaneous raw velocity data at 5 Hz, which were exported to a customized spreadsheet. The spreadsheet provided calculations for speed-based distances (eg, total distance; high-speed running, >14.4 km/h; and very-high-speed running, >18.1 km/h) and metabolic-power variables (eg, energy expenditure; average metabolic power; and high-power distance, >20 W/kg). The data show that speed-based distances and metabolic power varied between positional groups, although this was largely related to differences in time spent on field. The distance covered at high running speed was lower than that obtained from high-power thresholds for all positional groups; however, the difference between the 2 methods was greatest for hit-up forwards and adjustables. Positional differences existed for all metabolic parameters, although these are at least partially related to time spent on the field. Higher-speed running may underestimate the demands of match play when compared with high-power distance-although the degree of difference between the measures varied by position. The analysis of metabolic power may complement traditional speed-based classifications and improve our understanding of the demands of rugby league match play.

  2. Effects of pulse duration on magnetostimulation thresholds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saritas, Emine U., E-mail: saritas@ee.bilkent.edu.tr; Department of Electrical and Electronics Engineering, Bilkent University, Bilkent, Ankara 06800; National Magnetic Resonance Research Center

    durations. Results: The magnetostimulation limits decreased with increasing pulse duration (T{sub pulse}). For T{sub pulse} < 18 ms, the thresholds were significantly higher than at the longest pulse durations (p < 0.01, paired Wilcoxon signed-rank test). The normalized magnetostimulation threshold (B{sub Norm}) vs duration curve at all three frequencies agreed almost identically, indicating that the observed effect is independent of the operating frequency. At the shortest pulse duration (T{sub pulse} ≈ 2 ms), the thresholds were approximately 24% higher than at the asymptotes. The thresholds decreased to within 4% of their asymptotic values for T{sub pulse} > 20 ms. These trends were well characterized (R{sup 2} = 0.78) by a stretched exponential function given by B{sub Norm}=1+αe{sup −(T{sub p}{sub u}{sub l}{sub s}{sub e}/β){sup γ}}, where the fitted parameters were α = 0.44, β = 4.32, and γ = 0.60. Conclusions: This work shows for the first time that the magnetostimulation thresholds decrease with increasing pulse duration, and that this effect is independent of the operating frequency. Normalized threshold vs duration trends are almost identical for a 20-fold range of frequencies: the thresholds are significantly higher at short pulse durations and settle to within 4% of their asymptotic values for durations longer than 20 ms. These results emphasize the importance of matching the human-subject experiments to the imaging conditions of a particular setup. Knowing the dependence of the safety limits to all contributing factors is critical for increasing the time-efficiency of imaging systems that utilize time-varying magnetic fields.« less

  3. Highly reliable high-power AlGaAs/GaAs 808 nm diode laser bars

    NASA Astrophysics Data System (ADS)

    Hülsewede, R.; Schulze, H.; Sebastian, J.; Schröder, D.; Meusel, J.; Hennig, P.

    2007-02-01

    There are strong demands at the market to increase power and reliability for 808 nm diode laser bars. Responding to this JENOPTIK Diode Lab GmbH developed high performance 808 nm diode laser bars in the AlGaAs/GaAs material system with special emphasis to high power operation and long term stability. Optimization of the epitaxy structure and improvements in the diode laser bar design results in very high slope efficiency of >1.2 W/A, low threshold current and small beam divergence in slow axis direction. Including low serial resistance the overall wall plug efficiency is up to 65% for our 20%, 30% and 50% filling factor 10 mm diode laser bars. With the JENOPTIK Diode Lab cleaving and coating technique the maximum output power is 205 W in CW operation and 377 W in QCW operation (200 μs, 2% duty cycle) for bars with 50% filling factor. These bars mounted on micro channel cooled package are showing a very high reliability of >15.000 h. Mounted on conductive cooled package high power operation at 100 W is demonstrated for more than 5000h.

  4. A Two-Locus Global DNA Barcode for Land Plants: The Coding rbcL Gene Complements the Non-Coding trnH-psbA Spacer Region

    PubMed Central

    Kress, W. John; Erickson, David L.

    2007-01-01

    Background A useful DNA barcode requires sufficient sequence variation to distinguish between species and ease of application across a broad range of taxa. Discovery of a DNA barcode for land plants has been limited by intrinsically lower rates of sequence evolution in plant genomes than that observed in animals. This low rate has complicated the trade-off in finding a locus that is universal and readily sequenced and has sufficiently high sequence divergence at the species-level. Methodology/Principal Findings Here, a global plant DNA barcode system is evaluated by comparing universal application and degree of sequence divergence for nine putative barcode loci, including coding and non-coding regions, singly and in pairs across a phylogenetically diverse set of 48 genera (two species per genus). No single locus could discriminate among species in a pair in more than 79% of genera, whereas discrimination increased to nearly 88% when the non-coding trnH-psbA spacer was paired with one of three coding loci, including rbcL. In silico trials were conducted in which DNA sequences from GenBank were used to further evaluate the discriminatory power of a subset of these loci. These trials supported the earlier observation that trnH-psbA coupled with rbcL can correctly identify and discriminate among related species. Conclusions/Significance A combination of the non-coding trnH-psbA spacer region and a portion of the coding rbcL gene is recommended as a two-locus global land plant barcode that provides the necessary universality and species discrimination. PMID:17551588

  5. A two-locus global DNA barcode for land plants: the coding rbcL gene complements the non-coding trnH-psbA spacer region.

    PubMed

    Kress, W John; Erickson, David L

    2007-06-06

    A useful DNA barcode requires sufficient sequence variation to distinguish between species and ease of application across a broad range of taxa. Discovery of a DNA barcode for land plants has been limited by intrinsically lower rates of sequence evolution in plant genomes than that observed in animals. This low rate has complicated the trade-off in finding a locus that is universal and readily sequenced and has sufficiently high sequence divergence at the species-level. Here, a global plant DNA barcode system is evaluated by comparing universal application and degree of sequence divergence for nine putative barcode loci, including coding and non-coding regions, singly and in pairs across a phylogenetically diverse set of 48 genera (two species per genus). No single locus could discriminate among species in a pair in more than 79% of genera, whereas discrimination increased to nearly 88% when the non-coding trnH-psbA spacer was paired with one of three coding loci, including rbcL. In silico trials were conducted in which DNA sequences from GenBank were used to further evaluate the discriminatory power of a subset of these loci. These trials supported the earlier observation that trnH-psbA coupled with rbcL can correctly identify and discriminate among related species. A combination of the non-coding trnH-psbA spacer region and a portion of the coding rbcL gene is recommended as a two-locus global land plant barcode that provides the necessary universality and species discrimination.

  6. Refinement of a thermal threshold probe to prevent burns.

    PubMed

    Dixon, M J; Taylor, P M; Slingsby, L C; Murrell, J C

    2016-02-01

    Thermal threshold testing is commonly used for pain research. The stimulus may cause burning and merits prevention. Thermal probe modifications hypothesized to reduce burning were evaluated for practicality and effect. Studies were conducted on two humans and eight cats. Unmodified probe 0 was tested on two humans and promising modifications were also evaluated on cats. Probe 1 incorporated rapid cooling after threshold was reached: probe 1a used a Peltier system and probe 1b used water cooling. Probe 2 released skin contact immediately after threshold. Probe 3 (developed in the light of evidence of 'hot spots' in probe 0) incorporated reduced thermal mass and even heating across the skin contact area. Human skin was heated to 48℃ (6℃ above threshold) and the resulting burn was evaluated using area of injury and a simple descriptive scale (SDS). Probe 1a cooled the skin but required further heat dissipation, excessive power, was not 'fail-safe' and was inappropriate for animal mounting. Probe 1b caused less damage than no cooling (27 ± 13 and 38 ± 11 mm(2) respectively, P = 0.0266; median SDS 1.5 and 4 respectively, P = 0.0317) but was cumbersome. Probe 2 was unwieldy and was not evaluated further. Probe 3 produced even heating without blistering in humans. With probe 3 in cats, after opioid treatment, thermal threshold reached cut-out (55℃) on 24 occasions, exceeded 50℃ in a further 32 tests and exceeded 48℃ in the remainder. No skin damage was evident immediately after testing and mild hyperaemia in three cats at 2-3 days resolved rapidly. Probe 3 appeared to be suitable for thermal threshold testing. © The Author(s) 2015.

  7. Tagatose production with pH control in a stirred tank reactor containing immobilized L-arabinose rom Thermotoga neapolitana.

    PubMed

    Lim, Byung-Chul; Kim, Hye-Jung; Oh, Deok-Kun

    2008-06-01

    Chitopearl beads were used as immobilization supports for D-tagatose production from D-galactose by L-arabinose isomerase from Thermotoga neapolitana because chitopearl beads were more stable than alginate beads at temperatures above 60 degrees C. The pH and temperature for the maximum isomerization of galactose were 7.5 and 90 degrees C, respectively. In thermostability experiments, the half-lives of the immobilized enzyme at 70, 75, 80, 85, and 90 degrees C were 388, 106, 54, 36, and 22 h, respectively. The reaction temperature was determined to be 70 degrees C because the enzyme is highly stable up to 70 degrees C during the reaction. When the reaction time, galactose concentration, and temperature were increased, the pH of a mixture containing enzyme and galactose decreased by the Maillard reaction, resulting in decreased tagatose production. With pH control at 7.5, tagatose production (138 g/L) at 70 degrees C in a stirred tank reactor containing immobilized enzyme and 300 g/L galactose increased two times higher, comparing that without pH control.

  8. Underwater temporary threshold shift induced by octave-band noise in three species of pinniped.

    PubMed

    Kastak, D; Schusterman, R J; Southall, B L; Reichmuth, C J

    1999-08-01

    Pure-tone sound detection thresholds were obtained in water for one harbor seal (Phoca vitulina), two California sea lions (Zalophus californianus), and one northern elephant seal (Mirounga angustirostris) before and immediately following exposure to octave-band noise. Additional thresholds were obtained following a 24-h recovery period. Test frequencies ranged from 100 Hz to 2000 Hz and octave-band exposure levels were approximately 60-75 dB SL (sensation level at center frequency). Each subject was trained to dive into a noise field and remain stationed underwater during a noise-exposure period that lasted a total of 20-22 min. Following exposure, three of the subjects showed threshold shifts averaging 4.8 dB (Phoca), 4.9 dB (Zalophus), and 4.6 dB (Mirounga). Recovery to baseline threshold levels was observed in test sessions conducted within 24 h of noise exposure. Control sessions in which the subjects completed a simulated noise exposure produced shifts that were significantly smaller than those observed following noise exposure. These results indicate that noise of moderate intensity and duration is sufficient to induce TTS under water in these pinniped species.

  9. Asymmetric Waveforms Decrease Lethal Thresholds in High Frequency Irreversible Electroporation Therapies

    PubMed Central

    Sano, Michael B.; Fan, Richard E.; Xing, Lei

    2017-01-01

    Irreversible electroporation (IRE) is a promising non-thermal treatment for inoperable tumors which uses short (50–100 μs) high voltage monopolar pulses to disrupt the membranes of cells within a well-defined volume. Challenges with IRE include complex treatment planning and the induction of intense muscle contractions. High frequency IRE (H-FIRE) uses bursts of ultrashort (0.25–5 μs) alternating polarity pulses to produce more predictable ablations and alleviate muscle contractions associated with IRE. However, H-FIRE generally ablates smaller volumes of tissue than IRE. This study shows that asymmetric H-FIRE waveforms can be used to create ablation volumes equivalent to standard IRE treatments. Lethal thresholds (LT) of 505 V/cm and 1316 V/cm were found for brain cancer cells when 100 μs IRE and 2 μs symmetric H-FIRE waveforms were used. In contrast, LT as low as 536 V/cm were found for 2 μs asymmetric H-FIRE waveforms. Reversible electroporation thresholds were 54% lower than LTs for symmetric waveforms and 33% lower for asymmetric waveforms indicating that waveform symmetry can be used to tune the relative sizes of reversible and irreversible ablation zones. Numerical simulations predicted that asymmetric H-FIRE waveforms are capable of producing ablation volumes which were 5.8–6.3x larger than symmetric H-FIRE waveforms indicating that in vivo investigation of asymmetric waveforms is warranted. PMID:28106146

  10. Asymmetric Waveforms Decrease Lethal Thresholds in High Frequency Irreversible Electroporation Therapies

    NASA Astrophysics Data System (ADS)

    Sano, Michael B.; Fan, Richard E.; Xing, Lei

    2017-01-01

    Irreversible electroporation (IRE) is a promising non-thermal treatment for inoperable tumors which uses short (50-100 μs) high voltage monopolar pulses to disrupt the membranes of cells within a well-defined volume. Challenges with IRE include complex treatment planning and the induction of intense muscle contractions. High frequency IRE (H-FIRE) uses bursts of ultrashort (0.25-5 μs) alternating polarity pulses to produce more predictable ablations and alleviate muscle contractions associated with IRE. However, H-FIRE generally ablates smaller volumes of tissue than IRE. This study shows that asymmetric H-FIRE waveforms can be used to create ablation volumes equivalent to standard IRE treatments. Lethal thresholds (LT) of 505 V/cm and 1316 V/cm were found for brain cancer cells when 100 μs IRE and 2 μs symmetric H-FIRE waveforms were used. In contrast, LT as low as 536 V/cm were found for 2 μs asymmetric H-FIRE waveforms. Reversible electroporation thresholds were 54% lower than LTs for symmetric waveforms and 33% lower for asymmetric waveforms indicating that waveform symmetry can be used to tune the relative sizes of reversible and irreversible ablation zones. Numerical simulations predicted that asymmetric H-FIRE waveforms are capable of producing ablation volumes which were 5.8-6.3x larger than symmetric H-FIRE waveforms indicating that in vivo investigation of asymmetric waveforms is warranted.

  11. Réalisation de circuits intégrés I^2L à base de transistors bipolaires a double hétérojonction GaAlAs/GaAs

    NASA Astrophysics Data System (ADS)

    Vannel, J. P.; Camps, T.; Ferreira, A. S.; Tasselh, J.; Cazarré, A.; Marty, A.; Bailbé, J. P.

    1991-04-01

    GaAlAs/GaAs double heterojunction bipolar transistors (DHBT's) have a number of advantages for I^2L (integrated injection logic) high speed integrated circuits concerning the interchangeability between the emitter and the collector and a high design flexibility due to the use of two heterojunctions. We present the fabrication process of an I^2L integrated circuit including a frequency divider-by-two and a ring oscillator which presents a propagation delay time of 1.2 ns for a power consumption of 8 mW. Les transistors bipolaires à double hétérojonction GaAlAs/GaAs (TBDH) présentent de nombreux avantages pour leur application dans des circuits intégrés de logique I^2L (logique à injection intégrée), dont en particulier l'interchangeabilité entre émetteur et collecteur, et la liberté de conception résultant de l'utilisation de deux hétérojonctions. Dans ce cadre nous décrivons les principales étapes technologiques de fabrication d'un circuit intégré I^2L comportant un diviseur de fréquence par 2 et un oscillateur en anneau. Ce demier présente un temps de propagation de 1,2 ns pour une puissance dissipée de 8 mW.

  12. Monolayer semiconductor nanocavity lasers with ultralow thresholds

    DOE PAGES

    Wu, Sanfeng; Buckley, Sonia; Schaibley, John R.; ...

    2015-03-16

    Engineering the electromagnetic environment of a nanoscale light emitter by a photonic cavity can significantly enhance its spontaneous emission rate through cavity quantum electrodynamics in the Purcell regime. This effect can greatly reduce the lasing threshold of the emitter 1–5, providing the ultimate low-threshold laser system with small footprint, low power consumption and ultrafast modulation. A state-of-the-art ultra-low threshold nanolaser has been successfully developed though embedding quantum dots into photonic crystal cavity (PhCC) 6–8. However, several core challenges impede the practical applications of this architecture, including the random positions and compositional fluctuations of the dots 7, extreme difficulty in currentmore » injection8, and lack of compatibility with electronic circuits 7,8. Here, we report a new strategy to lase, where atomically thin crystalline semiconductor, i.e., a tungsten-diselenide (WSe 2) monolayer, is nondestructively and deterministically introduced as a gain medium at the surface of a pre-fabricated PhCC. A new type of continuous-wave nanolaser operating in the visible regime is achieved with an optical pumping threshold as low as 27 nW at 130 K, similar to the value achieved in quantum dot PhCC lasers 7. The key to the lasing action lies in the monolayer nature of the gain medium, which confines direct-gap excitons to within 1 nm of the PhCC surface. The surface-gain geometry allows unprecedented accessibilities to multi-functionalize the gain, enabling electrically pumped operation. Our scheme is scalable and compatible with integrated photonics for on-chip optical communication technologies.« less

  13. Power consumption for an agitated vessel equipped with pitched blade turbine and short baffles.

    PubMed

    Major-Godlewska, Marta; Karcz, Joanna

    2018-01-01

    Power characteristics for an agitated vessel equipped with planar short baffles of length L and pitched blade turbine of pitch β are presented in the paper. The studies were carried out in the vessel of inner diameter D  = 0.6 m, where the baffles were located in the distance p from the vessel bottom ( p  +  L  =  H ). Torque was measured using strain gauge method within the turbulent regime of the flow of Newtonian liquid in the agitated vessel. The effects of the pitch β and geometrical parameter p / H on the power number Ne were determined mathematically. The results showed that, for the assumed value of the angle β , the function Ne  =  f ( L / H ) decreases with the decrease in the baffle length L (i.e. with the increase in the parameter p ). Moreover, for the assumed value of the baffle length L , the function Ne  =  f ( β ) increases with the increase in the angle β of the inclination of the impeller blade.

  14. Effect of marination on CIE L* and pH values of chicken breast pectoralis major with different color lightness

    USDA-ARS?s Scientific Manuscript database

    Color lightness (CIE L* values) and pH are widely used as quality indicators for raw poultry breast fillets (pectoralis major). The objective of this study was to evaluate the effects of vacuum-tumbling marination on L* and pH values of raw chicken breast meat with different color lightness. Early ...

  15. Statistics of Fractionalized Excitations through Threshold Spectroscopy.

    PubMed

    Morampudi, Siddhardh C; Turner, Ari M; Pollmann, Frank; Wilczek, Frank

    2017-06-02

    We show that neutral anyonic excitations have a signature in spectroscopic measurements of materials: The low-energy onset of spectral functions near the threshold follows universal power laws with an exponent that depends only on the statistics of the anyons. This provides a route, using experimental techniques such as neutron scattering and tunneling spectroscopy, for detecting anyonic statistics in topologically ordered states such as gapped quantum spin liquids and hypothesized fractional Chern insulators. Our calculations also explain some recent theoretical results in spin systems.

  16. L-leucine, L-methionine, and L-phenylalanine share a Na(+)/K (+)-dependent amino acid transporter in shrimp hepatopancreas.

    PubMed

    Duka, Ada; Ahearn, Gregory A

    2013-08-01

    Hepatopancreatic brush border membrane vesicles (BBMV), made from Atlantic White shrimp (Litopenaeus setiferus), were used to characterize the transport properties of (3)H-L-leucine influx by these membrane systems and how other essential amino acids and the cations, sodium and potassium, interact with this transport system. (3)H-L-leucine uptake by BBMV was pH-sensitive and occurred against transient transmembrane concentration gradients in both Na(+)- and K(+)-containing incubation media, suggesting that either cation was capable of providing a driving force for amino acid accumulation. (3)H-L-leucine uptake in NaCl or KCl media were each three times greater in acidic pH (pH 5.5) than in alkaline pH (pH 8.5). The essential amino acid, L-methionine, at 20 mM significantly (p < 0.0001) inhibited the 2-min uptakes of 1 mM (3)H-L-leucine in both Na(+)- and K(+)-containing incubation media. The residual (3)H-L-leucine uptake in the two media were significantly greater than zero (p < 0.001), but not significantly different from each other (p > 0.05) and may represent an L-methionine- and cation-independent transport system. (3)H-L-leucine influxes in both NaCl and KCl incubation media were hyperbolic functions of [L-leucine], following the carrier-mediated Michaelis-Menten equation. In NaCl, (3)H-L-leucine influx displayed a low apparent K M (high affinity) and low apparent J max, while in KCl the transport exhibited a high apparent K M (low affinity) and high apparent J max. L-methionine or L-phenylalanine (7 and 20 mM) were competitive inhibitors of (3)H-L-leucine influxes in both NaCl and KCl media, producing a significant (p < 0.01) increase in (3)H-L-leucine influx K M, but no significant response in (3)H-L-leucine influx J max. Potassium was a competitive inhibitor of sodium co-transport with (3)H-L-leucine, significantly (p < 0.01) increasing (3)H-L-leucine influx K M in the presence of sodium, but having negligible effect on (3)H-L-leucine influx J

  17. Phonatory threshold pressure in a healthy population before and after aerosol treatment, a preliminary study.

    PubMed

    Grini-Grandval, M N; Bingenheimer, S; Maunsell, R; Ouaknine, M; Giovanni, A

    2002-01-01

    The viscosity of the surface mucus of the vocal cords is one of the important elements for good laryngeal functioning. It has been demonstrated that inhalation of hydrated air increases the phonatory threshold pressure by decreasing viscosity of the mucus (1) leading to a more regular vibration that can be appreciated by jitter (2). In an attempt to correlate the concepts of tissue viscosity and surface mucus considering the theoretical model of vibration we measured the phonatory threshold pressure in 6 healthy female subjects before and after aerosol treatment. We were able to demonstrate that the pressure threshold is lower (3.15 hPa) after aerosol treatment than before (3.79 hPa) and this was statistically significant (p: 0.041). The discussion is based on this decrease of mucus viscosity applied to the physiological concepts necessary to understand glottic vibration.

  18. ADAPTIVE THRESHOLD LOGIC.

    DTIC Science & Technology

    The design and construction of a 16 variable threshold logic gate with adaptable weights is described. The operating characteristics of tape wound...and sizes as well as for the 16 input adaptive threshold logic gate. (Author)

  19. Original Mercury Astronauts with Col. John A. (Shorty) Powers

    NASA Technical Reports Server (NTRS)

    1961-01-01

    Photo of the original Mercury Astronauts with Col. John A. (Shorty) Powers seated around a table talking to the news media. From left to right are: L. Gordon Cooper, Donald K. Slayton, John H. Glenn, Jr., Col. Powers, Alan B. Shepard Jr., M. Scott Carpenter, and Walter M. Schirra Jr. Virgil I. Grissom is out of the frame.

  20. Threshold behaviour of the π+π- invariant mass in nuclei

    NASA Astrophysics Data System (ADS)

    Camerini, P.; Grion, N.; Rui, R.; Vetterli, D.

    1993-02-01

    We present π+π- invariant-mass distributions between 300 and 380 MeV for the 2H, 4He, 16O, 208Pb(π +, π +π -) reaction at an incident π+ energy of 280 MeV. A prominent feature is the shift of their maximum downward to the 2m π threshold as A increases. This behaviour finds a qualitative explanation in the framework of a model that investigates the modification of the strength function for an interacting ( ππ) I = L = 0 system embedded in the nuclear medium. Also, the π+π- invariant-mass cross sections are compared with the predictions of an A( π+, π+π-) model that uses a microscopical approach for the elementary process of pion production, πN → ππ N. Four-fold differential cross sections as a function of the energy of outgoing π+ and p, and missing-mass distributions for the A( π+, pπ-) reaction are also presented for some of the examined nuclei. The experimental results are discussed within the framework of the two available models.

  1. Threshold Concepts in Biochemistry

    ERIC Educational Resources Information Center

    Loertscher, Jennifer

    2011-01-01

    Threshold concepts can be identified for any discipline and provide a framework for linking student learning to curricular design. Threshold concepts represent a transformed understanding of a discipline, without which the learner cannot progress and are therefore pivotal in learning in a discipline. Although threshold concepts have been…

  2. Minimal supersymmetric B - L extension of the standard model, heavy H and light h Higgs boson production and decay at future e + e - linear colliders

    NASA Astrophysics Data System (ADS)

    Ramírez-Sánchez, F.; Gutierrez-Rodríguez, A.; Hernández-Ruiz, M. A.

    2017-10-01

    We study the phenomenology of the light h and heavy H Higgs boson production and decay in the context of a U(1) B - L extension of the standard model with an additional Z´ boson at future e + e - linear colliders with center-of-mass energies of √𝑠 = 500 - 3000 GeV and integrated luminosities of L = 500 - 2000 fb-1. The study includes the processes e + e - → (Z, Z´) → Zh and e + e - → (Z, Z´) → ZH, considering both the resonant and non-resonant effects. We find that the total number of expected Zh and ZH events can reach 106 and 105, respectively, which is a very optimistic scenario allowing us to perform precision measurements for both Higgs bosons h and H, as well as for the Z‧ boson in future high-energy and high-luminosity e + e - colliders.

  3. Nociceptive Response to L-DOPA-Induced Dyskinesia in Hemiparkinsonian Rats.

    PubMed

    Nascimento, G C; Bariotto-Dos-Santos, K; Leite-Panissi, C R A; Del-Bel, E A; Bortolanza, M

    2018-04-02

    Non-motor symptoms are increasingly identified to present clinical and diagnostic importance for Parkinson's disease (PD). The multifactorial origin of pain in PD makes this symptom of great complexity. The dopamine precursor, L-DOPA (L-3,4-dihydroxyphenylalanine), the classic therapy for PD, seems to be effective in pain threshold; however, there are no studies correlating L-DOPA-induced dyskinesia (LID) and nociception development in experimental Parkinsonism. Here, we first investigated nociceptive responses in a 6-hydroxydopamine (6-OHDA)-lesioned rat model of Parkinson's disease to a hind paw-induced persistent inflammation. Further, the effect of L-DOPA on nociception behavior at different times of treatment was investigated. Pain threshold was determined using von Frey and Hot Plate/Tail Flick tests. Dyskinesia was measured by abnormal involuntary movements (AIMs) induced by L-DOPA administration. This data is consistent to show that 6-OHDA-lesioned rats had reduced nociceptive thresholds compared to non-lesioned rats. Additionally, when these rats were exposed to a persistent inflammatory challenge, we observed increased hypernociceptive responses, namely hyperalgesia. L-DOPA treatment alleviated pain responses on days 1 and 7 of treatment, but not on day 15. During that period, we observed an inverse relationship between LID and nociception threshold in these rats, with a high LID rate corresponding to a reduced nociception threshold. Interestingly, pain responses resulting from CFA-induced inflammation were significantly enhanced during established dyskinesia. These data suggest a pro-algesic effect of L-DOPA-induced dyskinesia, which is confirmed by the correlation founded here between AIMs and nociceptive indexes. In conclusion, our results are consistent with the notion that central dopaminergic mechanism is directly involved in nociceptive responses in Parkinsonism condition.

  4. Comparison of anaerobic threshold determined by visual and mathematical methods in healthy women.

    PubMed

    Higa, M N; Silva, E; Neves, V F C; Catai, A M; Gallo, L; Silva de Sá, M F

    2007-04-01

    Several methods are used to estimate anaerobic threshold (AT) during exercise. The aim of the present study was to compare AT obtained by a graphic visual method for the estimate of ventilatory and metabolic variables (gold standard), to a bi-segmental linear regression mathematical model of Hinkley's algorithm applied to heart rate (HR) and carbon dioxide output (VCO2) data. Thirteen young (24 +/- 2.63 years old) and 16 postmenopausal (57 +/- 4.79 years old) healthy and sedentary women were submitted to a continuous ergospirometric incremental test on an electromagnetic braking cycloergometer with 10 to 20 W/min increases until physical exhaustion. The ventilatory variables were recorded breath-to-breath and HR was obtained beat-to-beat over real time. Data were analyzed by the nonparametric Friedman test and Spearman correlation test with the level of significance set at 5%. Power output (W), HR (bpm), oxygen uptake (VO2; mL kg(-1) min(-1)), VO2 (mL/min), VCO2 (mL/min), and minute ventilation (VE; L/min) data observed at the AT level were similar for both methods and groups studied (P > 0.05). The VO2 (mL kg(-1) min(-1)) data showed significant correlation (P < 0.05) between the gold standard method and the mathematical model when applied to HR (rs = 0.75) and VCO2 (rs = 0.78) data for the subjects as a whole (N = 29). The proposed mathematical method for the detection of changes in response patterns of VCO2 and HR was adequate and promising for AT detection in young and middle-aged women, representing a semi-automatic, non-invasive and objective AT measurement.

  5. Continuous adjustment of threshold voltage in carbon nanotube field-effect transistors through gate engineering

    NASA Astrophysics Data System (ADS)

    Zhong, Donglai; Zhao, Chenyi; Liu, Lijun; Zhang, Zhiyong; Peng, Lian-Mao

    2018-04-01

    In this letter, we report a gate engineering method to adjust threshold voltage of carbon nanotube (CNT) based field-effect transistors (FETs) continuously in a wide range, which makes the application of CNT FETs especially in digital integrated circuits (ICs) easier. Top-gated FETs are fabricated using solution-processed CNT network films with stacking Pd and Sc films as gate electrodes. By decreasing the thickness of the lower layer metal (Pd) from 20 nm to zero, the effective work function of the gate decreases, thus tuning the threshold voltage (Vt) of CNT FETs from -1.0 V to 0.2 V. The continuous adjustment of threshold voltage through gate engineering lays a solid foundation for multi-threshold technology in CNT based ICs, which then can simultaneously provide high performance and low power circuit modules on one chip.

  6. Effect of marination on CIE L* and pH values of chicken breast pectoralis major with different color lightness

    USDA-ARS?s Scientific Manuscript database

    Color lightness (CIE L* values) and pH are widely used as quality indicators for raw poultry breast fillets (pectoralis major). The objective of this study was to evaluate the effects of vacuum-tumbling marination on L* and pH values of raw chicken breast meat with different color lightness. Early d...

  7. Ultra-Low Power Event-Driven Wireless Sensor Node Using Piezoelectric Accelerometer for Health Monitoring

    NASA Astrophysics Data System (ADS)

    Okada, Hironao; Kobayashi, Takeshi; Masuda, Takashi; Itoh, Toshihiro

    2009-07-01

    We describe a low power consumption wireless sensor node designed for monitoring the conditions of animals, especially of chickens. The node detects variations in 24-h behavior patterns by acquiring the number of the movement of an animal whose acceleration exceeds a threshold measured in per unit time. Wireless sensor nodes when operated intermittently are likely to miss necessary data during their sleep mode state and waste the power in the case of acquiring useless data. We design the node worked only when required acceleration is detected using a piezoelectric accelerometer and a comparator for wake-up source of micro controller unit.

  8. Evaluation of lophine derivatives as L-012 (luminol analog)-dependent chemiluminescence enhancers for measuring horseradish peroxidase and H2O2.

    PubMed

    Ichibangase, T; Ohba, Y; Kishikawa, N; Nakashima, K; Kuroda, N

    2014-03-01

    8-Amino-5-chloro-7-phenylpyrido[3,4-d]pyridazine-1,4(2H,3H)dione (L-012) was recently synthesized as a new chemiluminescence (CL) probe; the light intensity and the sensitivity of L-012 are higher than those of other CL probes such as luminol. Previously, our group developed four lophine-based CL enhancers of the horseradish peroxidase (HRP)-catalyzed CL oxidation of luminol, namely 2-(4-hydroxyphenyl)-4,5-diphenylimidazole (HDI), 2-(4-hydroxyphenyl)-4,5-di(2-pyridyl)imidazole (HPI), 4-(4,5-diphenyl-1H-imidazol-2-yl)phenylboronic acid (DPA), and 4-[4,5-di(2-pyridyl)-1H-imidazol-2-yl]phenylboronic acid (DPPA), and showed that DPPA was suitable for the photographic detection of HRP. In this study, we replaced luminol with L-012 and evaluated these as L-012-dependent CL enhancers. In addition, to detect HRP and/or H2O2 with higher sensitivity, each detection condition for the L-012-HRP-H2O2 enhanced CL was optimized. All the derivatives enhanced the L-012-dependent CL as well as luminol CL; HPI generated the highest enhanced luminescence. Under optimized conditions for HRP detection, the detection limit of HRP was 0.08 fmol. By contrast, the detection limit of HRP with the enhanced L-012-dependent CL using 4-iodophenol, which is a common enhancer of luminol CL, was 1.1 fmol. With regard to H2O2 detection, the detection limits for enhanced CL with HPI and 4-iodophenol were 0.29 and 1.5 pmol, respectively. Therefore, it is demonstrated that HPI is the most superior L-012-dependent CL enhancer. Copyright © 2013 John Wiley & Sons, Ltd.

  9. The effect of sertraline and 8-OH-DPAT on the PTZ_induced seizure threshold: Role of the nitrergic system.

    PubMed

    Heydari, Azhdar; Davoudi, Shima

    2017-02-01

    Serotonin is a key regulatory neurotransmitter in the CNS which plays an important role in seizure through different receptors, especially the 5HT 1A subtype. The role of sertraline through the 5HT 1A receptor and nitric oxide interaction on the PTZ-induced seizure threshold was investigated in this study. In this study, 70 white male mice were randomly divided into 10 groups including intact control, sham-control and eight experimental groups which received sertraline, 8-OH-DPAT, WAY100635, WAY100635+sertraline, WAY100635+8-OH-DPAT, L-NAME, L-NAME+sertraline and L-NAME+8-OH-DPAT. After 14days of treatment in different groups, the PTZ-induced seizure threshold was assessed and the measurement of nitric oxide metabolites in the brain tissue was done with the Greiss method. The seizure threshold was significantly increased in the sertraline and 8OH-DPAT receiving groups compared to the sham group (P<0.001). In the presence of WAY100635, the effect of both sertraline and 8-OH-DPAT in raising the seizure threshold was more prominent (P<0.001) but on the other hand, in the presence of L-NAME, an increase in the anticonvulsant effect of 8-OH-DPAT was observed, while L-NAME alone had no effect on the seizure threshold (P<0.001). The NO X concentration was significantly decreased in the 8-OH-DPAT_treated group (P<0.01), while the WAY100657 reversed it and the combination of 8-OH-DPAT with L-NAME reduced the NO X levels (P<0.001). These findings support the anticonvulsant effect of SSRIs and selective 5HT 1A receptors, although serotonin receptors other than 5HT 1A subtype may be involved and also it is probable that some anticonvulsant effects of the sertraline and 8-OH-DPAT are through the modulation of nitrergic system. Copyright © 2016 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  10. Six weeks of a polarized training-intensity distribution leads to greater physiological and performance adaptations than a threshold model in trained cyclists.

    PubMed

    Neal, Craig M; Hunter, Angus M; Brennan, Lorraine; O'Sullivan, Aifric; Hamilton, D Lee; De Vito, Giuseppe; Galloway, Stuart D R

    2013-02-15

    This study was undertaken to investigate physiological adaptation with two endurance-training periods differing in intensity distribution. In a randomized crossover fashion, separated by 4 wk of detraining, 12 male cyclists completed two 6-wk training periods: 1) a polarized model [6.4 (±1.4 SD) h/wk; 80%, 0%, and 20% of training time in low-, moderate-, and high-intensity zones, respectively]; and 2) a threshold model [7.5 (±2.0 SD) h/wk; 57%, 43%, and 0% training-intensity distribution]. Before and after each training period, following 2 days of diet and exercise control, fasted skeletal muscle biopsies were obtained for mitochondrial enzyme activity and monocarboxylate transporter (MCT) 1 and 4 expression, and morning first-void urine samples were collected for NMR spectroscopy-based metabolomics analysis. Endurance performance (40-km time trial), incremental exercise, peak power output (PPO), and high-intensity exercise capacity (95% maximal work rate to exhaustion) were also assessed. Endurance performance, PPOs, lactate threshold (LT), MCT4, and high-intensity exercise capacity all increased over both training periods. Improvements were greater following polarized rather than threshold for PPO [mean (±SE) change of 8 (±2)% vs. 3 (±1)%, P < 0.05], LT [9 (±3)% vs. 2 (±4)%, P < 0.05], and high-intensity exercise capacity [85 (±14)% vs. 37 (±14)%, P < 0.05]. No changes in mitochondrial enzyme activities or MCT1 were observed following training. A significant multilevel, partial least squares-discriminant analysis model was obtained for the threshold model but not the polarized model in the metabolomics analysis. A polarized training distribution results in greater systemic adaptation over 6 wk in already well-trained cyclists. Markers of muscle metabolic adaptation are largely unchanged, but metabolomics markers suggest different cellular metabolic stress that requires further investigation.

  11. Mitochondrial threshold effects.

    PubMed Central

    Rossignol, Rodrigue; Faustin, Benjamin; Rocher, Christophe; Malgat, Monique; Mazat, Jean-Pierre; Letellier, Thierry

    2003-01-01

    The study of mitochondrial diseases has revealed dramatic variability in the phenotypic presentation of mitochondrial genetic defects. To attempt to understand this variability, different authors have studied energy metabolism in transmitochondrial cell lines carrying different proportions of various pathogenic mutations in their mitochondrial DNA. The same kinds of experiments have been performed on isolated mitochondria and on tissue biopsies taken from patients with mitochondrial diseases. The results have shown that, in most cases, phenotypic manifestation of the genetic defect occurs only when a threshold level is exceeded, and this phenomenon has been named the 'phenotypic threshold effect'. Subsequently, several authors showed that it was possible to inhibit considerably the activity of a respiratory chain complex, up to a critical value, without affecting the rate of mitochondrial respiration or ATP synthesis. This phenomenon was called the 'biochemical threshold effect'. More recently, quantitative analysis of the effects of various mutations in mitochondrial DNA on the rate of mitochondrial protein synthesis has revealed the existence of a 'translational threshold effect'. In this review these different mitochondrial threshold effects are discussed, along with their molecular bases and the roles that they play in the presentation of mitochondrial diseases. PMID:12467494

  12. Thresholds for short-term acid and aluminum impacts on Atlantic salmon smolts

    USGS Publications Warehouse

    McCormick, Stephen D.; Lerner, Darrren T.; Regish, Amy M.; O'Dea, Michael F.; Monette, Michelle Y.

    2012-01-01

    Although the negative effects of acid and aluminum (Al) on smolt development have been known for some time, the thresholds for impact of short-term exposure of several days that may occur during episodic acidification have not been systematically examined. In order to determine the levels of acid and Al that impact juvenile Atlantic salmon, smolts and yolk-sac larvae were exposed to three pH levels (6.0, 5.7, and 5.3) and four added Al levels (0, 40, 80 and 175 μg/L total Al) for 48 h. Following this treatment, 10 smolts were sampled in freshwater and another 10 were subjected to a 24 h seawater challenge (35 ppt). Survival of yolk-sac larvae was > 96% in all acid and Al treatments. All smolts died within 48 h at pH 5.3, 175 μg L− 1 Al. There were some mortalities in freshwater at pH 5.3, 80 μg L− 1 Al and pH 5.7, 175 μg L− 1 Al, and further mortalities when these fish were transferred to seawater. Mortalities in these groups were associated with decreased plasma chloride in freshwater and higher plasma chloride in seawater, indicating that these smolts had lost seawater tolerance. Gill Na+/K+-ATPase (NKA) activity decreased at pH 5.7, 175 μg L− 1 Al in freshwater, and further decreases were observed at more moderate pH and Al exposures after transfer to seawater. Hematocrit and plasma glucose were the most sensitive physiological responses, increasing at all Al treatments at pH 5.7 and 5.3 in freshwater. There was no detectable increase in gill Al levels at pH 6.0 with added Al, whereas substantial increases in gill Al were observed in all added Al groups at pH 5.7 and 5.3. Our results demonstrate a critical interaction between acid and Al in their effects on smolts, and that episodic acidification events will negatively impact smolt survival in freshwater and after seawater entry.

  13. An Integrated Gate Driver in 4H-SiC for Power Converter Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ericson, Milton Nance; Frank, Steven Shane; Britton, Charles

    2014-01-01

    A gate driver fabricated in a 2-um 4H silicon carbide (SiC) process is presented. This process was optimized for vertical power MOSFET fabrication but accommodated integration of a few low-voltage device types including N-channel MOSFETs, resistors, and capacitors. The gate driver topology employed incorporates an input level translator, variable power connections, and separate power supply connectivity allowing selection of the output signal drive amplitude. The output stage utilizes a source follower pull-up device that is both overdriven and body source connected to improve rise time behavior. Full characterization of this design driving a SiC power MOSFET is presented including risemore » and fall times, propagation delays, and power consumption. All parameters were measured to elevated temperatures exceeding 300 C. Details of the custom test system hardware and software utilized for gate driver testing are also provided.« less

  14. Threshold concepts in prosthetics.

    PubMed

    Hill, Sophie

    2017-12-01

    Curriculum documents identify key concepts within learning prosthetics. Threshold concepts provide an alternative way of viewing the curriculum, focussing on the ways of thinking and practicing within prosthetics. Threshold concepts can be described as an opening to a different way of viewing a concept. This article forms part of a larger study exploring what students and staff experience as difficult in learning about prosthetics. To explore possible threshold concepts within prosthetics. Qualitative, interpretative phenomenological analysis. Data from 18 students and 8 staff at two universities with undergraduate prosthetics and orthotics programmes were generated through interviews and questionnaires. The data were analysed using an interpretative phenomenological analysis approach. Three possible threshold concepts arose from the data: 'how we walk', 'learning to talk' and 'considering the person'. Three potential threshold concepts in prosthetics are suggested with possible implications for prosthetics education. These possible threshold concepts involve changes in both conceptual and ontological knowledge, integrating into the persona of the individual. This integration occurs through the development of memories associated with procedural concepts that combine with disciplinary concepts. Considering the prosthetics curriculum through the lens of threshold concepts enables a focus on how students learn to become prosthetists. Clinical relevance This study provides new insights into how prosthetists learn. This has implications for curriculum design in prosthetics education.

  15. 77 FR 38729 - Alternate Tonnage Threshold for Oil Spill Response Vessels

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-29

    ...The Coast Guard is establishing an alternate size threshold based on the measurement system established under the International Convention on Tonnage Measurement of Ships, 1969, for oil spill response vessels, which are properly certificated under 46 CFR chapter I, subchapter L. The present size threshold of 500 gross register tons is based on the U.S. regulatory measurement system. This final rule provides an alternative for owners and operators of offshore supply vessels that may result in an increase in oil spill response capacity and capability. This final rule adopts, without change, the interim rule amending 46 CFR part 126 published in the Federal Register on Monday, December 12, 2011.

  16. Hydrogen Learning for Local Leaders – H2L3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Serfass, Patrick

    The Hydrogen Learning for Local Leaders program, H2L3, elevates the knowledge about hydrogen by local government officials across the United States. The program reaches local leaders directly through “Hydrogen 101” workshops and webinar sessions; the creation and dissemination of a unique report on the hydrogen and fuel cell market in the US, covering 57 different sectors; and support of the Hydrogen Student Design Contest, a competition for interdisciplinary teams of university students to design hydrogen and fuel cell systems based on technology that’s currently commercially available.

  17. Atomic, Molecular, and Optical Physics: Optical Excitation Function of H(1s-2p) Produced by electron Impact from Threshold to 1.8 keV

    NASA Technical Reports Server (NTRS)

    James, G. K.; Slevin, J. A.; Shemansky, D. E.; McConkey, J. W.; Bray, I.; Dziczek, D.; Kanik, I.; Ajello, J. M.

    1997-01-01

    The optical excitation function of prompt Lyman-Alpha radiation, produced by electron impact on atomic hydrogen, has been measured over the extended energy range from threshold to 1.8 keV. Measurements were obtained in a crossed-beams experiment using both magnetically confined and electrostatically focused electrons in collision with atomic hydrogen produced by an intense discharge source. A vacuum-ultraviolet mono- chromator system was used to measure the emitted Lyman-Alpha radiation. The absolute H(1s-2p) electron impact excitation cross section was obtained from the experimental optical excitation function by normalizing to the accepted optical oscillator strength, with corrections for polarization and cascade. Statistical and known systematic uncertainties in our data range from +/- 4% near threshold to +/- 2% at 1.8 keV. Multistate coupling affecting the shape of the excitation function up to 1 keV impact energy is apparent in both the present experimental data and present theoretical results obtained with convergent close- coupling (CCC) theory. This shape function effect leads to an uncertainty in absolute cross sections at the 10% level in the analysis of the experimental data. The derived optimized absolute cross sections are within 7% of the CCC calculations over the 14 eV-1.8 keV range. The present CCC calculations converge on the Bethe- Fano profile for H(1s-2p) excitation at high energy. For this reason agreement with the CCC values to within 3% is achieved in a nonoptimal normalization of the experimental data to the Bethe-Fano profile. The fundamental H(1s-2p) electron impact cross section is thereby determined to an unprecedented accuracy over the 14 eV - 1.8 keV energy range.

  18. Identification of a Hemolysis Threshold That Increases Plasma and Serum Zinc Concentration.

    PubMed

    Killilea, David W; Rohner, Fabian; Ghosh, Shibani; Otoo, Gloria E; Smith, Lauren; Siekmann, Jonathan H; King, Janet C

    2017-06-01

    Background: Plasma or serum zinc concentration (PZC or SZC) is the primary measure of zinc status, but accurate sampling requires controlling for hemolysis to prevent leakage of zinc from erythrocytes. It is not established how much hemolysis can occur without changing PZC/SZC concentrations. Objective: This study determines a guideline for the level of hemolysis that can significantly elevate PZC/SZC. Methods: The effect of hemolysis on PZC/SZC was estimated by using standard hematologic variables and mineral content. The calculated hemolysis threshold was then compared with results from an in vitro study and a population survey. Hemolysis was assessed by hemoglobin and iron concentrations, direct spectrophotometry, and visual assessment of the plasma or serum. Zinc and iron concentrations were determined by inductively coupled plasma spectrometry. Results: A 5% increase in PZC/SZC was calculated to result from the lysis of 1.15% of the erythrocytes in whole blood, corresponding to ∼1 g hemoglobin/L added into the plasma or serum. Similarly, the addition of simulated hemolysate to control plasma in vitro caused a 5% increase in PZC when hemoglobin concentrations reached 1.18 ± 0.10 g/L. In addition, serum samples from a population nutritional survey were scored for hemolysis and analyzed for changes in SZC; samples with hemolysis in the range of 1-2.5 g hemoglobin/L showed an estimated increase in SZC of 6% compared with nonhemolyzed samples. Each approach indicated that a 5% increase in PZC/SZC occurs at ∼1 g hemoglobin/L in plasma or serum. This concentration of hemoglobin can be readily identified directly by chemical hemoglobin assays or indirectly by direct spectrophotometry or matching to a color scale. Conclusions: A threshold of 1 g hemoglobin/L is recommended for PZC/SZC measurements to avoid increases in zinc caused by hemolysis. The use of this threshold may improve zinc assessment for monitoring zinc status and nutritional interventions.

  19. Direct N2H4/H2O2 Fuel Cells Powered by Nanoporous Gold Leaves

    PubMed Central

    Yan, Xiuling; Meng, Fanhui; Xie, Yun; Liu, Jianguo; Ding, Yi

    2012-01-01

    Dealloyed nanoporous gold leaves (NPGLs) are found to exhibit high electrocatalytic properties toward both hydrazine (N2H4) oxidation and hydrogen peroxide (H2O2) reduction. This observation allows the implementation of a direct hydrazine-hydrogen peroxide fuel cell (DHHPFC) based on these novel porous membrane catalysts. The effects of fuel and oxidizer flow rate, concentration and cell temperature on the performance of DHHPFC are systematically investigated. With a loading of ~0.1 mg cm−2 Au on each side, an open circuit voltage (OCV) of 1.2 V is obtained at 80°C with a maximum power density 195 mW cm−2, which is 22 times higher than that of commercial Pt/C electrocatalyst at the same noble metal loading. NPGLs thus hold great potential as effective and stable electrocatalysts for DHHPFCs. PMID:23230507

  20. Congenital Hypothyroidism with Neurological and Respiratory Alterations: A Case Detected Using a Variable Diagnostic Threshold for TSH

    PubMed Central

    Barreiro, Jesús; Castro-Feijoo, Lidia; Colón, Cristóbal; Cabanas, Paloma; Heredia, Claudia; Castaño, Luis Antonio; Gómez-Lado, Carmen; Couce, M.Luz; Pombo, Manuel

    2011-01-01

    We report a case of congenital hypothyroidism (CH) with neurological and respiratory alterations due to a heterozygotic c.374-1G > A mutation of TITF1/NKX2-1. The hypothyroidism was detected using a neonatal screening protocol in which the thyroid stimulating hormone (TSH) threshold is re-set each day on the basis of within-day variability and between-day variation. In this case, the threshold on the day of the initial analysis was 8.2 mIU/L, and the measured TSH level in heel-prick blood was 8.3 mIU/L. Conflict of interest:None declared. PMID:22155464

  1. Cost and Performance Report: Solar-Powered Remediation and pH Control

    DTIC Science & Technology

    2017-04-01

    OMB (Office of Management and Budget) Circular A-94. 2016. Guidelines and Discount Rates for Benefit - Cost Analysis of Federal Programs. Rahner D...ER-201033) Solar-Powered Remediation and pH Control April 2017 This document has been cleared for public release; Distribution Statement A...Program (ESTCP). The publication of this report does not indicate endorsement by the Department of Defense, nor should the contents be construed

  2. Melatonin partially protects 661W cells from H2O2-induced death by inhibiting Fas/FasL-caspase-3.

    PubMed

    Sánchez-Bretaño, Aída; Baba, Kenkichi; Janjua, Uzair; Piano, Ilaria; Gargini, Claudia; Tosini, Gianluca

    2017-01-01

    Previous studies have shown that melatonin (MEL) signaling is involved in the modulation of photoreceptor viability during aging. Recent work by our laboratory suggested that MEL may protect cones by modulating the Fas/FasL-caspase-3 pathway. In this study, we first investigated the presence of MEL receptors (MT 1 and MT 2 ) in 661W cells, then whether MEL can prevent H 2 O 2 -induced cell death, and last, through which pathway MEL confers protection. The mRNA and proteins of the MEL receptors were detected with quantitative PCR (q-PCR) and immunocytochemistry, respectively. To test the protective effect of MEL, 661W cells were treated with H 2 O 2 for 2 h in the presence or absence of MEL, a MEL agonist, and an antagonist. To study the pathways involved in H 2 O 2 -mediated cell death, a Fas/FasL antagonist was used before the exposure to H 2 O 2 . Finally, Fas/FasL and caspase-3 mRNA was analyzed with q-PCR and immunocytochemistry in cells treated with H 2 O 2 and/or MEL. Cell viability was analyzed by using Trypan Blue. Both MEL receptors (MT 1 and MT 2 ) were detected at the mRNA and protein levels in 661W cells. MEL partially prevented H 2 O 2 -mediated cell death (20-25%). This effect was replicated with IIK7 (a melatonin receptor agonist) when used at a concentration of 1 µM. Preincubation with luzindole (a melatonin receptor antagonist) blocked MEL protection. Kp7-6, an antagonist of Fas/FasL, blocked cell death caused by H 2 O 2 similarly to what was observed for MEL. Fas, FasL, and caspase-3 expression was increased in cells treated with H 2 O 2 , and this effect was prevented by MEL. Finally, MEL treatment partially prevented the activation of caspase-3 caused by H 2 O 2 . The results demonstrate that MEL receptors are present and functional in 661W cells. MEL can prevent photoreceptor cell death induced by H 2 O 2 via the inhibition of the proapoptotic pathway Fas/FasL-caspase-3.

  3. Metal-organic framework: Structure and magnetic properties of [Cu3(BTC)2 (L)x·(CuO)y]n (L=H2O, DMF)

    NASA Astrophysics Data System (ADS)

    da Silva, Gilvaldo G.; Machado, F. L. A.; Junior, S. Alves; Padrón-Hernández, E.

    2017-09-01

    The compounds [Cu3(BTC)2(L)x·(CuO)y], with BTC (benzene 1,3,5-tricarboxylate) and L (H2O or DMF) were prepared using electrochemical synthesis. Structural and morphologic characterizations were performed by X-ray diffraction and scanning electronic microscopy. The [Cu3(BTC)2 (L)x·(CuO)y] contain dimeric [Cu2(O2CR)]4 units with three possible spin configurations arising from Cu(II) 3d9 states and Cu-Cu δ bond. We observed an unusual very strong antiferromagnetic coupling in temperatures ranging from 100 K to 350 K for [Cu3(BTC)2.(H2O)3. (CuO)y]n. The inverse susceptibility versus temperature shows a linearity from 20 K up to 65 K fitting the Curie-Weiss law, for L = DMF. The CW X-band electron paramagnetic resonance spectroscopy (EPR) was important to explore the coordination state for DMF in the network. It was observed that DMF is located in an equatorial geometry of the coordination network experimenting interactions from the nitrogen and copper ions.

  4. A high-throughput method to measure NaCl and acid taste thresholds in mice.

    PubMed

    Ishiwatari, Yutaka; Bachmanov, Alexander A

    2009-05-01

    To develop a technique suitable for measuring NaCl taste thresholds in genetic studies, we conducted a series of experiments with outbred CD-1 mice using conditioned taste aversion (CTA) and two-bottle preference tests. In Experiment 1, we compared conditioning procedures involving either oral self-administration of LiCl or pairing NaCl intake with LiCl injections and found that thresholds were the lowest after LiCl self-administration. In Experiment 2, we compared different procedures (30-min and 48-h tests) for testing conditioned mice and found that the 48-h test is more sensitive. In Experiment 3, we examined the effects of varying strength of conditioned (NaCl or LiCl taste intensity) and unconditioned (LiCl toxicity) stimuli and concluded that 75-150 mM LiCl or its mixtures with NaCl are the optimal stimuli for conditioning by oral self-administration. In Experiment 4, we examined whether this technique is applicable for measuring taste thresholds for other taste stimuli. Results of these experiments show that conditioning by oral self-administration of LiCl solutions or its mixtures with other taste stimuli followed by 48-h two-bottle tests of concentration series of a conditioned stimulus is an efficient and sensitive method to measure taste thresholds. Thresholds measured with this technique were 2 mM for NaCl and 1 mM for citric acid. This approach is suitable for simultaneous testing of large numbers of animals, which is required for genetic studies. These data demonstrate that mice, like several other species, generalize CTA from LiCl to NaCl, suggesting that they perceive taste of NaCl and LiCl as qualitatively similar, and they also can generalize CTA of a binary mixture of taste stimuli to mixture components.

  5. Anaerobic threshold determination through ventilatory and electromyographics parameters.

    PubMed

    Gassi, E R; Bankoff, A D P

    2010-01-01

    The aim of present study was to compare the alterations in electromyography signs with Ventilatory Threshold (VT). Had been part of the study eight men, amateur cyclists and triathletes (25.25 +/- 6.96 years), that they had exercised themselves in a mechanical cicloergometer, a cadence of 80 RPM and with the increased intensity being in 25 W/min until the exhaustion. The VT was determined by a non-linear increase in VE/VO2 without any increase in VE/VCO2 and compared with the intensity corresponding to break point of amplitude EMG sign during the incremental exercise. The EMG--Fatigue Threshold (FT) and Ventilatory Threshold (VT) parameters used were the power, the time, absolute and relative VO2, ventilation (VE), the heart hate (HH) and the subjective perception of the effort. The results had not shown to difference in none of the variable selected for the corresponding intensity to VT and FT--EMG of the muscles lateralis vastus and femoris rectus. The parameters used in the comparison between the electromyographic indicators and ventilatory were the load, the time, absolute VO2 and relative to corporal mass, to ventilation (VE), the heart frequency (HH) and the Subjective Perception of the Effort (SPE).

  6. Stationary zonal flows during the formation of the edge transport barrier in the JET tokamak

    DOE PAGES

    Hillesheim, J. C.; Meyer, H.; Maggi, C. F.; ...

    2016-02-10

    In this study, high spatial resolution Doppler backscattering measurements in JET have enabled new insights into the development of the edge E r. We observe fine-scale spatial structures in the edge E r well with a wave number k rρi ≈ 0.4-0.8, consistent with stationary zonal flows, the characteristics of which vary with density. The zonal flow amplitude and wavelength both decrease with local collisionality, such that the zonal flow E x B shear increases. Above the minimum of the L-H transition power threshold dependence on density, the zonal flows are present during L mode and disappear following the H-modemore » transition, while below the minimum they are reduced below measurable amplitude during L mode, before the L-H transition.« less

  7. Rapid wall relaxation in elongating tissues. [Glycine max (L. ); Pisum sativum L

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matyssek, R.; Maruyama, S.; Boyer, J.S.

    1988-01-01

    Reported differences in the relaxation of cell walls in enlarging stem tissues of soybean (Glycine max (L.) Merr.) and pea (Pisum sativum L.) cause measurements of the yield threshold turgor, an important growth parameter, to be in doubt. Using the pressure probe and guillotine psychrometer, the authors investigated wall relaxation in these species by excising the elongating tissue in air to remove the water supply. The authors found that the rapid kinetics usually exhibited by soybean could be delayed and made similar to the slow kinetics previously reported for pea if slowly growing or mature tissue was left attached tomore » the rapidly growing tissue when relaxation was initiated. The greater the amount of attached tissue, the slower the relaxation, suggesting that slowly growing tissue acted as a water source. Consistent with this concept was a lower water potential in the rapidly elongating tissue than in the slowly growing tissue. If this tissue was removed from pea, relaxation became as rapid as usually exhibited by soybean. It is concluded that the true relaxation of cell walls to the yield threshold requires only a few minutes and that the yield threshold in the intact plant before excision. Under these conditions, the yield threshold was close to the turgor in the intact plant regardless of the species.« less

  8. Modeling of divertor power footprint widths on EAST by SOLPS5.0/B2.5-Eirene

    NASA Astrophysics Data System (ADS)

    Deng, Guozhong; Liu, Xiaoju; Wang, Liang; Liu, Shaocheng; Xu, Jichan; Feng, Wei; Liu, Jianbin; Liu, Huan; Gao, Xiang

    2017-04-01

    The edge plasma code package SOLPS5.0 is employed to simulate the divertor power footprint widths of the experimental advanced superconducting tokamak (EAST) L-mode and ELM-free H-mode plasmas. The divertor power footprint widths, which consist of the scrape-off layer (SOL) width λ q and heat spreading S, are important physical parameters for edge plasmas. In this work, a plasma current scan is implemented in the simulation to obtain the dependence of the divertor power footprint width on the plasma current I p. Strong inverse scaling of the SOL width with I p has been achieved for both L-mode and H-mode plasmas in the forms of {λ }q,{{L}\\text-\\text{mode}}=4.98× {I}{{p}}-0.68 and {λ }q,{{H}\\text-\\text{mode}}=1.86× {I}{{p}}-1.08. Similar trends have also been demonstrated in the study of heat spreading with {S}{{L}\\text-\\text{mode}}=1.95× {I}{{p}}-0.542 and {S}{{H}\\text-\\text{mode}}=0.756× {I}{{p}}-0.872. In addition, studies on divertor peak heat load and the magnetic flux expansion factor show that both of them are proportional to plasma current. The simulation work here can act as a way to explore the power footprint widths of future tokamak fusion devices such as ITER and the China Fusion Engineering Test Reactor (CFETR).

  9. Crystal and molecular structure of 2,2’-(quinoxaline-2,3-diyl)dipyridinium dinitrate (H{sub 2}L)(NO{sub 3}){sub 2}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Egorova, O. A.; Polyakova, I. N., E-mail: polyakova@igic.ras.ru; Sergienko, V. S.

    2016-07-15

    The crystal structure of 2,2’-(quinoxaline-2,3-diyl)dipyridinium dinitrate (H{sub 2}L)(NO{sub 3}){sub 2} is studied by X-ray diffraction (T = 150 K, R1 = 0.0467). The H{sub 2}L{sup 2+} cation is located on the twofold rotation axis and connected with two NO{sub 3}{sup −} anions by strong N–H···O hydrogen bonds. Planar quinoxaline fragments of cations form stacks with the interplanar spacing of 3.308 Å. The structure of the diprotonated H{sub 2}L{sup 2+} cation is compared with those of the monoprotonated H{sub 2}L{sup 2+} cation and neutral L molecule.

  10. Power Systems Life Cycle Analysis Tool (Power L-CAT).

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andruski, Joel; Drennen, Thomas E.

    2011-01-01

    The Power Systems L-CAT is a high-level dynamic model that calculates levelized production costs and tracks environmental performance for a range of electricity generation technologies: natural gas combined cycle (using either imported (LNGCC) or domestic natural gas (NGCC)), integrated gasification combined cycle (IGCC), supercritical pulverized coal (SCPC), existing pulverized coal (EXPC), nuclear, and wind. All of the fossil fuel technologies also include an option for including carbon capture and sequestration technologies (CCS). The model allows for quick sensitivity analysis on key technical and financial assumptions, such as: capital, O&M, and fuel costs; interest rates; construction time; heat rates; taxes; depreciation;more » and capacity factors. The fossil fuel options are based on detailed life cycle analysis reports conducted by the National Energy Technology Laboratory (NETL). For each of these technologies, NETL's detailed LCAs include consideration of five stages associated with energy production: raw material acquisition (RMA), raw material transport (RMT), energy conversion facility (ECF), product transportation and distribution (PT&D), and end user electricity consumption. The goal of the NETL studies is to compare existing and future fossil fuel technology options using a cradle-to-grave analysis. The NETL reports consider constant dollar levelized cost of delivered electricity, total plant costs, greenhouse gas emissions, criteria air pollutants, mercury (Hg) and ammonia (NH3) emissions, water withdrawal and consumption, and land use (acreage).« less

  11. Power Enhancement in High Dimensional Cross-Sectional Tests

    PubMed Central

    Fan, Jianqing; Liao, Yuan; Yao, Jiawei

    2016-01-01

    We propose a novel technique to boost the power of testing a high-dimensional vector H : θ = 0 against sparse alternatives where the null hypothesis is violated only by a couple of components. Existing tests based on quadratic forms such as the Wald statistic often suffer from low powers due to the accumulation of errors in estimating high-dimensional parameters. More powerful tests for sparse alternatives such as thresholding and extreme-value tests, on the other hand, require either stringent conditions or bootstrap to derive the null distribution and often suffer from size distortions due to the slow convergence. Based on a screening technique, we introduce a “power enhancement component”, which is zero under the null hypothesis with high probability, but diverges quickly under sparse alternatives. The proposed test statistic combines the power enhancement component with an asymptotically pivotal statistic, and strengthens the power under sparse alternatives. The null distribution does not require stringent regularity conditions, and is completely determined by that of the pivotal statistic. As specific applications, the proposed methods are applied to testing the factor pricing models and validating the cross-sectional independence in panel data models. PMID:26778846

  12. Balancing computation and communication power in power constrained clusters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piga, Leonardo; Paul, Indrani; Huang, Wei

    Systems, apparatuses, and methods for balancing computation and communication power in power constrained environments. A data processing cluster with a plurality of compute nodes may perform parallel processing of a workload in a power constrained environment. Nodes that finish tasks early may be power-gated based on one or more conditions. In some scenarios, a node may predict a wait duration and go into a reduced power consumption state if the wait duration is predicted to be greater than a threshold. The power saved by power-gating one or more nodes may be reassigned for use by other nodes. A cluster agentmore » may be configured to reassign the unused power to the active nodes to expedite workload processing.« less

  13. Metabolic Tumor Volume and Total Lesion Glycolysis in Oropharyngeal Cancer Treated With Definitive Radiotherapy: Which Threshold Is the Best Predictor of Local Control?

    PubMed

    Castelli, Joël; Depeursinge, Adrien; de Bari, Berardino; Devillers, Anne; de Crevoisier, Renaud; Bourhis, Jean; Prior, John O

    2017-06-01

    In the context of oropharyngeal cancer treated with definitive radiotherapy, the aim of this retrospective study was to identify the best threshold value to compute metabolic tumor volume (MTV) and/or total lesion glycolysis to predict local-regional control (LRC) and disease-free survival. One hundred twenty patients with a locally advanced oropharyngeal cancer from 2 different institutions treated with definitive radiotherapy underwent FDG PET/CT before treatment. Various MTVs and total lesion glycolysis were defined based on 2 segmentation methods: (i) an absolute threshold of SUV (0-20 g/mL) or (ii) a relative threshold for SUVmax (0%-100%). The parameters' predictive capabilities for disease-free survival and LRC were assessed using the Harrell C-index and Cox regression model. Relative thresholds between 40% and 68% and absolute threshold between 5.5 and 7 had a similar predictive value for LRC (C-index = 0.65 and 0.64, respectively). Metabolic tumor volume had a higher predictive value than gross tumor volume (C-index = 0.61) and SUVmax (C-index = 0.54). Metabolic tumor volume computed with a relative threshold of 51% of SUVmax was the best predictor of disease-free survival (hazard ratio, 1.23 [per 10 mL], P = 0.009) and LRC (hazard ratio: 1.22 [per 10 mL], P = 0.02). The use of different thresholds within a reasonable range (between 5.5 and 7 for an absolute threshold and between 40% and 68% for a relative threshold) seems to have no major impact on the predictive value of MTV. This parameter may be used to identify patient with a high risk of recurrence and who may benefit from treatment intensification.

  14. Shifts in the relationship between motor unit recruitment thresholds versus derecruitment thresholds during fatigue.

    PubMed

    Stock, Matt S; Mota, Jacob A

    2017-12-01

    Muscle fatigue is associated with diminished twitch force amplitude. We examined changes in the motor unit recruitment versus derecruitment threshold relationship during fatigue. Nine men (mean age = 26 years) performed repeated isometric contractions at 50% maximal voluntary contraction (MVC) knee extensor force until exhaustion. Surface electromyographic signals were detected from the vastus lateralis, and were decomposed into their constituent motor unit action potential trains. Motor unit recruitment and derecruitment thresholds and firing rates at recruitment and derecruitment were evaluated at the beginning, middle, and end of the protocol. On average, 15 motor units were studied per contraction. For the initial contraction, three subjects showed greater recruitment thresholds than derecruitment thresholds for all motor units. Five subjects showed greater recruitment thresholds than derecruitment thresholds for only low-threshold motor units at the beginning, with a mean cross-over of 31.6% MVC. As the muscle fatigued, many motor units were derecruited at progressively higher forces. In turn, decreased slopes and increased y-intercepts were observed. These shifts were complemented by increased firing rates at derecruitment relative to recruitment. As the vastus lateralis fatigued, the central nervous system's compensatory adjustments resulted in a shift of the regression line of the recruitment versus derecruitment threshold relationship. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. Noise masking of S-cone increments and decrements.

    PubMed

    Wang, Quanhong; Richters, David P; Eskew, Rhea T

    2014-11-12

    S-cone increment and decrement detection thresholds were measured in the presence of bipolar, dynamic noise masks. Noise chromaticities were the L-, M-, and S-cone directions, as well as L-M, L+M, and achromatic (L+M+S) directions. Noise contrast power was varied to measure threshold Energy versus Noise (EvN) functions. S+ and S- thresholds were similarly, and weakly, raised by achromatic noise. However, S+ thresholds were much more elevated by S, L+M, L-M, L- and M-cone noises than were S- thresholds, even though the noises consisted of two symmetric chromatic polarities of equal contrast power. A linear cone combination model accounts for the overall pattern of masking of a single test polarity well. L and M cones have opposite signs in their effects upon raising S+ and S- thresholds. The results strongly indicate that the psychophysical mechanisms responsible for S+ and S- detection, presumably based on S-ON and S-OFF pathways, are distinct, unipolar mechanisms, and that they have different spatiotemporal sampling characteristics, or contrast gains, or both. © 2014 ARVO.

  16. Post-prandial carbohydrate ingestion during 1-h of moderate-intensity, intermittent cycling does not improve mood, perceived exertion, or subsequent power output in recreationally-active exercisers

    PubMed Central

    2013-01-01

    Background This study compared the effects of ingesting water (W), a flavored carbohydrate-electrolyte (CE) or a flavored non-caloric electrolyte (NCE) beverage on mood, ratings of perceived exertion (RPE), and sprint power during cycling in recreational exercisers. Methods Men (n = 23) and women (n = 13) consumed a 24–h standardized diet and reported 2–4 h post-prandial for all test sessions. After a familiarization session, participants completed 50 min of stationary cycling in a warm environment (wet bulb globe temperature = 25.0°C) at ~ 60-65% of heart rate reserve (146 ± 4 bpm) interspersed with 5 rest periods of 2 min each. During exercise, participants consumed W, CE, or NCE, served in a counterbalanced cross-over design. Beverage volume was served in 3 aliquots equaling each individual’s sweat losses (mean 847 ± 368 mL) during the familiarization session. Profiles of Mood States questionnaires (POMS) were administered and blood glucose levels were determined pre- and post- sub-maximal cycling. Following sub-maximal exercise, participants completed 3 30–s Wingate anaerobic tests (WAnT) with 2.5 min rest between tests to assess performance. Results Blood glucose was higher (p <  0.05) after 50 min of submaximal cycling just prior to the WAnT for CE (6.1 ± 1.7 mmol/L) compared to W (4.9 ± 1.5 mmol/L) and NCE (4.6 ± 1.2 mmol/L). Nonetheless, there were no differences among treatments in peak (642 ± 153, 635 ± 143, 650 ± 141 watts for W, NCE, and CE, respectively; p  =  0.44) or mean (455 ± 100, 458 ± 95, 454 ± 95 watts for W, NCE, and CE, respectively; p = 0.62) power for the first WAnT or mean (414 ± 92, 425 ± 85, 423 ± 82 watts, respectively; p = 0.13) power output averaged across all 3 WAnT. Likewise, RPE during submaximal exercise, session RPE, and fatigue and vigor assessed by POMS did not differ among beverage treatments (p > 0.05). Conclusions

  17. Should high-power posing be integrated in physical therapy?

    PubMed

    Ge, Weiqing; Bennett, Teale K; Oller, Jeremy C

    2017-04-01

    [Purpose] Postural assessment and correction is a common approach in patient management to decrease symptoms and improve function for patients. The purpose of this study was to determine the effects of high-power posing on muscle strength and pain threshold. [Subjects and Methods] Thirty-one subjects, 16 females and 15 males, mean age 28.9 (SD 10.8) years old, were recruited through a convenience sampling on the university campus. The research design was a randomized controlled trial. In the experimental group, the subjects were instructed to stand in a high-power posture. In the control group, the subjects were instructed to stand in a low-power posture. Grip strength and pain threshold measurements were conducted before and after the postural intervention. [Results] The grip strength changed by -3.4 (-3.7, 0.3) % and 1.7 (-3.6, 5.3) % for the experimental and control groups, respectively. The pain threshold changed by 0.6 (-9.9, 10.4) % and 15.1 (-9.3, 24.4) % for the experimental and control groups, respectively. However, both changes were not significant as all the 95% CIs included 0. [Conclusions] The data did not show significant benefits of high-power posing in increasing grip strength and pain threshold compared to low-power posing.

  18. Application of automatic threshold in dynamic target recognition with low contrast

    NASA Astrophysics Data System (ADS)

    Miao, Hua; Guo, Xiaoming; Chen, Yu

    2014-11-01

    Hybrid photoelectric joint transform correlator can realize automatic real-time recognition with high precision through the combination of optical devices and electronic devices. When recognizing targets with low contrast using photoelectric joint transform correlator, because of the difference of attitude, brightness and grayscale between target and template, only four to five frames of dynamic targets can be recognized without any processing. CCD camera is used to capture the dynamic target images and the capturing speed of CCD is 25 frames per second. Automatic threshold has many advantages like fast processing speed, effectively shielding noise interference, enhancing diffraction energy of useful information and better reserving outline of target and template, so this method plays a very important role in target recognition with optical correlation method. However, the automatic obtained threshold by program can not achieve the best recognition results for dynamic targets. The reason is that outline information is broken to some extent. Optimal threshold is obtained by manual intervention in most cases. Aiming at the characteristics of dynamic targets, the processing program of improved automatic threshold is finished by multiplying OTSU threshold of target and template by scale coefficient of the processed image, and combining with mathematical morphology. The optimal threshold can be achieved automatically by improved automatic threshold processing for dynamic low contrast target images. The recognition rate of dynamic targets is improved through decreased background noise effect and increased correlation information. A series of dynamic tank images with the speed about 70 km/h are adapted as target images. The 1st frame of this series of tanks can correlate only with the 3rd frame without any processing. Through OTSU threshold, the 80th frame can be recognized. By automatic threshold processing of the joint images, this number can be increased to 89 frames

  19. Prolonged noise exposure-induced auditory threshold shifts in rats

    PubMed Central

    Chen, Guang-Di; Decker, Brandon; Muthaiah, Vijaya Prakash Krishnan; Sheppard, Adam; Salvi, Richard

    2014-01-01

    Noise-induced hearing loss (NIHL) initially increases with exposure duration, but eventually reaches an asymptotic threshold shift (ATS) once the exposure duration exceeds 18-24 h. Equations for predicting the ATS have been developed for several species, but not for rats, even though this species is extensively used in noise exposure research. To fill this void, we exposed rats to narrowband noise (NBN, 16-20 kHz) for 5 weeks starting at 80 dB SPL in the first week and then increasing the level by 6 dB per week to a final level of 104 dB SPL. Auditory brainstem responses (ABR) were recorded before, during, and following the exposure to determine the amount of hearing loss. The noise induced threshold shift to continuous long-term exposure, defined as compound threshold shift (CTS), within and above 16-20 kHz increased with noise level at the rate of 1.82 dB threshold shift per dB of noise level (NL) above a critical level (C) of 77.2 dB SPL i.e. CTS = 1.82(NL-77.2). The normalized amplitude of the largest ABR peak measured at 100 dB SPL decreased at the rate of 3.1% per dB of NL above the critical level of 76.9 dB SPL, i.e., %ABR Reduction = 3.1%(NL-76.9). ABR thresholds measured >30 days post-exposure only partially recovered resulting in a permanent threshold shift of 30-40 dB along with severe hair cell loss in the basal, high-frequency region of the cochlea. In the rat, CTS increases with noise level with a slope similar to humans and chinchillas. The critical level (C) in the rat is similar to that of humans, but higher than that of chinchillas. PMID:25219503

  20. Low Cost High-H 2 Syngas Production for Power and Liquid Fuels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, S. James

    2015-07-31

    This report summarizes the technical progress made of the research project entitled “Low Cost High-H2 Syngas Production for Power and Liquid Fuels,” under DOE Contract No. DE-FE-0011958. The period of performance was October 1, 2013 through July 30, 2015. The overall objectives of this project was to determine the technical and economic feasibility of a systems approach for producing high hydrogen syngas from coal with the potential to reduce significantly the cost of producing power, chemical-grade hydrogen or liquid fuels, with carbon capture to reduce the environmental impact of gasification. The project encompasses several areas of study and the resultsmore » are summarized here. (1) Experimental work to determine the technical feasibility of a novel hybrid polymer/metal H2-membrane to recover pure H2 from a coal-derived syngas was done. This task was not successful. Membranes were synthesized and show impermeability of any gases at required conditions. The cause of this impermeability was most likely due to the densification of the porous polymer membrane support made from polybenzimidazole (PBI) at test temperatures above 250 °C. (2) Bench-scale experimental work was performed to extend GTI's current database on the University of California Sulfur Recovery Process-High Pressure (UCSRP-HP) and recently renamed Sulfur Removal and Recovery (SR2) process for syngas cleanup including removal of sulfur and other trace contaminants, such as, chlorides and ammonia. The SR2 process tests show >90% H2S conversion with outlet H2S concentrations less than 4 ppmv, and 80-90% ammonia and chloride removal with high mass transfer rates. (3) Techno-economic analyses (TEA) were done for the production of electric power, chemical-grade hydrogen and diesel fuels, from a mixture of coal- plus natural gas-derived syngas using the Aerojet Rocketdyne (AR) Advanced Compact coal gasifier and a natural gas partial oxidation reactor (POX) with SR2 technology. Due to the

  1. Threshold factorization redux

    NASA Astrophysics Data System (ADS)

    Chay, Junegone; Kim, Chul

    2018-05-01

    We reanalyze the factorization theorems for the Drell-Yan process and for deep inelastic scattering near threshold, as constructed in the framework of the soft-collinear effective theory (SCET), from a new, consistent perspective. In order to formulate the factorization near threshold in SCET, we should include an additional degree of freedom with small energy, collinear to the beam direction. The corresponding collinear-soft mode is included to describe the parton distribution function (PDF) near threshold. The soft function is modified by subtracting the contribution of the collinear-soft modes in order to avoid double counting on the overlap region. As a result, the proper soft function becomes infrared finite, and all the factorized parts are free of rapidity divergence. Furthermore, the separation of the relevant scales in each factorized part becomes manifest. We apply the same idea to the dihadron production in e+e- annihilation near threshold, and show that the resultant soft function is also free of infrared and rapidity divergences.

  2. Sparse Adaptive Iteratively-Weighted Thresholding Algorithm (SAITA) for Lp-Regularization Using the Multiple Sub-Dictionary Representation.

    PubMed

    Li, Yunyi; Zhang, Jie; Fan, Shangang; Yang, Jie; Xiong, Jian; Cheng, Xiefeng; Sari, Hikmet; Adachi, Fumiyuki; Gui, Guan

    2017-12-15

    Both L 1/2 and L 2/3 are two typical non-convex regularizations of L p (0thresholding algorithm and then proposes a sparse adaptive iterative-weighted L p thresholding algorithm (SAITA). Moreover, a simple yet effective regularization parameter is proposed to weight each sub-dictionary-based L p regularizer. Simulation results have shown that the proposed SAITA not only performs better than the corresponding L₁ algorithms but can also obtain a better recovery performance and achieve faster convergence than the conventional single-dictionary sparse transform-based L p case. Moreover, we conduct some applications about sparse image recovery and obtain good results by comparison with relative work.

  3. Step length and individual anaerobic threshold assessment in swimming.

    PubMed

    Fernandes, R J; Sousa, M; Machado, L; Vilas-Boas, J P

    2011-12-01

    Anaerobic threshold is widely used for diagnosis of swimming aerobic endurance but the precise incremental protocols step duration for its assessment is controversial. A physiological and biomechanical comparison between intermittent incremental protocols with different step lengths and a maximal lactate steady state (MLSS) test was conducted. 17 swimmers performed 7×200, 300 and 400 m (30 s and 24 h rest between steps and protocols) in front crawl until exhaustion and an MLSS test. The blood lactate concentration values ([La-]) at individual anaerobic threshold were 2.1±0.1, 2.2±0.2 and 1.8±0.1 mmol.l - 1 in the 200, 300 and 400 m protocols (with significant differences between 300 and 400 m tests), and 2.9±1.2 mmol.l - 1 at MLSS (higher than the incremental protocols); all these values are much lower than the traditional 4 mmol.l - 1 value. The velocities at individual anaerobic threshold obtained in incremental protocols were similar (and highly related) to the MLSS, being considerably lower than the velocity at 4 mmol.l - 1. Stroke rate increased and stroke length decreased throughout the different incremental protocols. It was concluded that it is valid to use intermittent incremental protocols of 200 and 300 m lengths to assess the swimming velocity corresponding to individual anaerobic threshold, the progressive protocols tend to underestimate the [La-] at anaerobic threshold assessed by the MLSS test, and swimmers increase velocity through stroke rate increases. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Setting conservation management thresholds using a novel participatory modeling approach.

    PubMed

    Addison, P F E; de Bie, K; Rumpff, L

    2015-10-01

    We devised a participatory modeling approach for setting management thresholds that show when management intervention is required to address undesirable ecosystem changes. This approach was designed to be used when management thresholds: must be set for environmental indicators in the face of multiple competing objectives; need to incorporate scientific understanding and value judgments; and will be set by participants with limited modeling experience. We applied our approach to a case study where management thresholds were set for a mat-forming brown alga, Hormosira banksii, in a protected area management context. Participants, including management staff and scientists, were involved in a workshop to test the approach, and set management thresholds to address the threat of trampling by visitors to an intertidal rocky reef. The approach involved trading off the environmental objective, to maintain the condition of intertidal reef communities, with social and economic objectives to ensure management intervention was cost-effective. Ecological scenarios, developed using scenario planning, were a key feature that provided the foundation for where to set management thresholds. The scenarios developed represented declines in percent cover of H. banksii that may occur under increased threatening processes. Participants defined 4 discrete management alternatives to address the threat of trampling and estimated the effect of these alternatives on the objectives under each ecological scenario. A weighted additive model was used to aggregate participants' consequence estimates. Model outputs (decision scores) clearly expressed uncertainty, which can be considered by decision makers and used to inform where to set management thresholds. This approach encourages a proactive form of conservation, where management thresholds and associated actions are defined a priori for ecological indicators, rather than reacting to unexpected ecosystem changes in the future. © 2015 The

  5. Comparison between intensity- duration thresholds and cumulative rainfall thresholds for the forecasting of landslide

    NASA Astrophysics Data System (ADS)

    Lagomarsino, Daniela; Rosi, Ascanio; Rossi, Guglielmo; Segoni, Samuele; Catani, Filippo

    2014-05-01

    This work makes a quantitative comparison between the results of landslide forecasting obtained using two different rainfall threshold models, one using intensity-duration thresholds and the other based on cumulative rainfall thresholds in an area of northern Tuscany of 116 km2. The first methodology identifies rainfall intensity-duration thresholds by means a software called MaCumBA (Massive CUMulative Brisk Analyzer) that analyzes rain-gauge records, extracts the intensities (I) and durations (D) of the rainstorms associated with the initiation of landslides, plots these values on a diagram, and identifies thresholds that define the lower bounds of the I-D values. A back analysis using data from past events can be used to identify the threshold conditions associated with the least amount of false alarms. The second method (SIGMA) is based on the hypothesis that anomalous or extreme values of rainfall are responsible for landslide triggering: the statistical distribution of the rainfall series is analyzed, and multiples of the standard deviation (σ) are used as thresholds to discriminate between ordinary and extraordinary rainfall events. The name of the model, SIGMA, reflects the central role of the standard deviations in the proposed methodology. The definition of intensity-duration rainfall thresholds requires the combined use of rainfall measurements and an inventory of dated landslides, whereas SIGMA model can be implemented using only rainfall data. These two methodologies were applied in an area of 116 km2 where a database of 1200 landslides was available for the period 2000-2012. The results obtained are compared and discussed. Although several examples of visual comparisons between different intensity-duration rainfall thresholds are reported in the international literature, a quantitative comparison between thresholds obtained in the same area using different techniques and approaches is a relatively undebated research topic.

  6. 1H NMR quantitative determination of photosynthetic pigments from green beans (Phaseolus vulgaris L.).

    PubMed

    Valverde, Juan; This, Hervé

    2008-01-23

    Using 1H nuclear magnetic resonance spectroscopy (1D and 2D), the two types of photosynthetic pigments (chlorophylls, their derivatives, and carotenoids) of "green beans" (immature pods of Phaseolus vulgaris L.) were analyzed. Compared to other analytical methods (light spectroscopy or chromatography), 1H NMR spectroscopy is a fast analytical way that provides more information on chlorophyll derivatives (allomers and epimers) than ultraviolet-visible spectroscopy. Moreover, it gives a large amount of data without prior chromatographic separation.

  7. Long-term outcomes in patients with septic shock transfused at a lower versus a higher haemoglobin threshold: the TRISS randomised, multicentre clinical trial.

    PubMed

    Rygård, Sofie L; Holst, Lars B; Wetterslev, Jørn; Winkel, Per; Johansson, Pär I; Wernerman, Jan; Guttormsen, Anne B; Karlsson, Sari; Perner, Anders

    2016-11-01

    We assessed the predefined long-term outcomes in patients randomised in the Transfusion Requirements in Septic Shock (TRISS) trial. In 32 Scandinavian ICUs, we randomised 1005 patients with septic shock and haemoglobin of 9 g/dl or less to receive single units of leuko-reduced red cells when haemoglobin level was 7 g/dl or less (lower threshold) or 9 g/dl or less (higher threshold) during ICU stay. We assessed mortality rates 1 year after randomisation and again in all patients at time of longest follow-up in the intention-to-treat population (n = 998) and health-related quality of life (HRQoL) 1 year after randomisation in the Danish patients only (n = 777). Mortality rates in the lower- versus higher-threshold group at 1 year were 53.5 % (268/501 patients) versus 54.6 % (271/496) [relative risk 0.97; 95 % confidence interval (CI) 0.85-1.09; P = 0.62]; at longest follow-up (median 21 months), they were 56.7 % (284/501) versus 61.0 % (302/495) (hazard ratio 0.88; 95 % CI 0.75-1.03; P = 0.12). We obtained HRQoL data at 1 year in 629 of the 777 (81 %) Danish patients, and mean differences between the lower- and higher-threshold group in scores of physical HRQoL were 0.4 (95 % CI -2.4 to 3.1; P = 0.79) and in mental HRQoL 0.5 (95 % CI -3.1 to 4.0; P = 0.79). Long-term mortality rates and HRQoL did not differ in patients with septic shock and anaemia who were transfused at a haemoglobin threshold of 7 g/dl versus a threshold of 9 g/dl. We may reject a more than 3 % increased hazard of death in the lower- versus higher-threshold group at the time of longest follow-up.

  8. Thermal bistability-based method for real-time optimization of ultralow-threshold whispering gallery mode microlasers.

    PubMed

    Lin, Guoping; Candela, Y; Tillement, O; Cai, Zhiping; Lefèvre-Seguin, V; Hare, J

    2012-12-15

    A method based on thermal bistability for ultralow-threshold microlaser optimization is demonstrated. When sweeping the pump laser frequency across a pump resonance, the dynamic thermal bistability slows down the power variation. The resulting line shape modification enables a real-time monitoring of the laser characteristic. We demonstrate this method for a functionalized microsphere exhibiting a submicrowatt laser threshold. This approach is confirmed by comparing the results with a step-by-step recording in quasi-static thermal conditions.

  9. Long Carbon Chains in the Warm Carbon-chain-chemistry Source L1527: First Detection of C7H in Molecular Clouds

    NASA Astrophysics Data System (ADS)

    Araki, Mitsunori; Takano, Shuro; Sakai, Nami; Yamamoto, Satoshi; Oyama, Takahiro; Kuze, Nobuhiko; Tsukiyama, Koichi

    2017-09-01

    Long carbon-chain molecules were searched for toward the low-mass star-forming region L1527, which is a prototypical source of warm carbon-chain chemistry (WCCC), using the 100 m Green Bank Telescope. Long carbon-chain molecules, C7H (2Π1/2), C6H (2Π3/2 and 2Π1/2), CH3C4H, and C6H2 (cumulene carbene, CCCCCCH2), and cyclic species of C3H and C3H2O were detected. In particular, C7H was detected for the first time in molecular clouds. The column density of C7H is determined to be 6 × 1010 cm-2. The column densities of the carbon-chain molecules including CH3C4H and C6H in L1527 relative to those in the starless dark cloud Taurus Molecular Cloud-1 Cyanopolyyne Peak (TMC-1 CP) tend to be systematically lower for long carbon-chain lengths. However, the column densities of C7H and C6H2 do not follow this trend and are found to be relatively abundant in L1527. This result implies that these long carbon-chain molecules are remnants of the cold starless phase. The results—that both the remnants and WCCC products are observed toward L1527—are consistent with the suggestion that the protostar can also be born in the parent core at a relatively early stage in the chemical evolution.

  10. Measuring Input Thresholds on an Existing Board

    NASA Technical Reports Server (NTRS)

    Kuperman, Igor; Gutrich, Daniel G.; Berkun, Andrew C.

    2011-01-01

    A critical PECL (positive emitter-coupled logic) interface to Xilinx interface needed to be changed on an existing flight board. The new Xilinx input interface used a CMOS (complementary metal-oxide semiconductor) type of input, and the driver could meet its thresholds typically, but not in worst-case, according to the data sheet. The previous interface had been based on comparison with an external reference, but the CMOS input is based on comparison with an internal divider from the power supply. A way to measure what the exact input threshold was for this device for 64 inputs on a flight board was needed. The measurement technique allowed an accurate measurement of the voltage required to switch a Xilinx input from high to low for each of the 64 lines, while only probing two of them. Directly driving an external voltage was considered too risky, and tests done on any other unit could not be used to qualify the flight board. The two lines directly probed gave an absolute voltage threshold calibration, while data collected on the remaining 62 lines without probing gave relative measurements that could be used to identify any outliers. The PECL interface was forced to a long-period square wave by driving a saturated square wave into the ADC (analog to digital converter). The active pull-down circuit was turned off, causing each line to rise rapidly and fall slowly according to the input s weak pull-down circuitry. The fall time shows up as a change in the pulse width of the signal ready by the Xilinx. This change in pulse width is a function of capacitance, pulldown current, and input threshold. Capacitance was known from the different trace lengths, plus a gate input capacitance, which is the same for all inputs. The pull-down current is the same for all inputs including the two that are probed directly. The data was combined, and the Excel solver tool was used to find input thresholds for the 62 lines. This was repeated over different supply voltages and

  11. Magnesium Sulfate Only Slightly Reduces the Shivering Threshold in Humans

    PubMed Central

    Wadhwa, Anupama; Sengupta, Papiya; Durrani, Jaleel; Akça, Ozan; Lenhardt, Rainer; Sessler, Daniel I.

    2005-01-01

    Background: Hypothermia may be an effective treatment for stroke or acute myocardial infarction; however, it provokes vigorous shivering, which causes potentially dangerous hemodynamic responses and prevents further hypothermia. Magnesium is an attractive antishivering agent because it is used for treatment of postoperative shivering and provides protection against ischemic injury in animal models. We tested the hypothesis that magnesium reduces the threshold (triggering core temperature) and gain of shivering without substantial sedation or muscle weakness. Methods: We studied nine healthy male volunteers (18-40 yr) on two randomly assigned treatment days: 1) Control and 2) Magnesium (80 mg·kg-1 followed by infusion at 2 g·h-1). Lactated Ringer's solution (4°C) was infused via a central venous catheter over a period of approximately 2 hours to decrease tympanic membrane temperature ≈1.5°C·h-1. A significant and persistent increase in oxygen consumption identified the threshold. The gain of shivering was determined by the slope of oxygen consumption vs. core temperature regression. Sedation was evaluated using verbal rating score (VRS, 0-10) and bispectral index of the EEG (BIS). Peripheral muscle strength was evaluated using dynamometry and spirometry. Data were analyzed using repeated-measures ANOVA; P<0.05 was statistically significant. Results: Magnesium reduced the shivering threshold (36.3±0.4 [mean±SD] vs. 36.6±0.3°C, P=0.040). It did not affect the gain of shivering (Control: 437±289, Magnesium: 573±370 ml·min-1·°C-1, P=0.344). The magnesium bolus did not produce significant sedation or appreciably reduce muscle strength. Conclusions: Magnesium significantly reduced the shivering threshold; however, due to the modest absolute reduction, this finding is considered to be clinically unimportant for induction of therapeutic hypothermia. PMID:15749735

  12. 40 CFR 68.115 - Threshold determination.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 15 2011-07-01 2011-07-01 false Threshold determination. 68.115... § 68.115 Threshold determination. (a) A threshold quantity of a regulated substance listed in § 68.130... process exceeds the threshold. (b) For the purposes of determining whether more than a threshold quantity...

  13. Clove oil induces anaesthesia and blunts muscle contraction power in three Amazon fish species.

    PubMed

    Fujimoto, Rodrigo Yudi; Pereira, Débora Martins; Silva, Jessica Cristina Souza; de Oliveira, Laís Cássia Araújo; Inoue, Luis Antonio Kioshi Aoki; Hamoy, Moisés; de Mello, Vanessa Jóia; Torres, Marcelo Ferreira; Barbas, Luis André Luz

    2018-02-01

    Clove oil is used as an anaesthetic for many species of fish worldwide; however, relatively few studies have assessed its effectiveness on Amazon fish species and no compelling evidence has ever been reported on the relaxant properties of this oil for skeletal muscle of fish. Thus, the objective of this study was to evaluate the latencies to deep anaesthesia and recovery, along with the myorelaxant effect of clove oil on three Amazon fish species: cardinal tetra, Paracheirodon axelrodi, banded cichlid, Heros severus and angelfish, Pterophyllum scalare, submitted to short-term anaesthetic baths. Fish were assayed in three groups of 60 fish each and individually anaesthetized in a completely randomized design with six clove oil concentrations using 10 fish/species/concentration. Electromyographic recordings from dorsal muscle were performed during stages of induction and recovery in which nine fish/species/stage were used. Deep anaesthesia was attained for all concentrations tested, and no mortalities were observed throughout the experiments and after a 48-h observation period. Concentration of 90 μL L -1 and above promoted fast deep anaesthesia (< 3 min) and calm recovery in angelfish and cardinal tetra, whereas the concentration of 60 μL L -1 sufficed to quickly anaesthetize banded cichlid. Times to full recovery were not significantly contrasting among species and occurred within appropriate time threshold (< 5 min). Clove oil exerted a conspicuous depression of muscle contraction power, and therefore can be effectively used as a muscle relaxant agent for P. scalare, P. axelrodi, H. severus and potentially, for other fish species.

  14. Effect of pH on skin permeation enhancement of acidic drugs by l-menthol-ethanol system.

    PubMed

    Katayama, K; Matsui, R; Hatanaka, T; Koizumi, T

    2001-09-11

    The effect of pH on the skin permeation enhancement of three acidic drugs by the l-menthol-ethanol system was investigated. The total flux of acidic drugs from the system remarkably varied over the pH range 3.0-8.0, and the permeation enhancement factor depended on the system pH and drug. A skin permeation model, which consists of two permeant (unionized and ionized) species, two system (oily and aqueous) phases, and two permeation (lipid and pore) pathways, was developed. The assumptions were made that only the unionized species can distribute to the oily phase and transport via the lipid pathway. The model explained the relationship between the concentration of drug in the aqueous phase and system pH. The skin permeability data were also described by the model and permeability coefficients corresponding to the physicochemical properties of permeant were calculated for the lipid and pore pathways. The model simulation showed that the permeation of acidic drugs occurred from the aqueous phase and the oily phase acted as a reservoir. Whether the total flux increased with increase of pH was dependent on the lipophilicity of drug. These results suggest that the pH of l-menthol-ethanol system should be given attention to elicit the maximum permeation enhancement.

  15. Cost efficacy of routine screening for diabetes in pregnancy: 1-h versus 2-h specimen.

    PubMed

    Weiner, C P; Fraser, M M; Burns, J M; Schnoor, D; Herrig, J; Whitaker, L A

    1986-01-01

    Undetected gestational diabetes mellitus (GDM) is associated with a two- to fivefold increase in perinatal morbidity and mortality. Widespread screening of the obstetric population (resulting in identification and treatment) should reduce these rates. Seven hundred ninety-eight women were examined during a 13-mo period of universal glucose challenge testing (GCT). A total of 2.8% of the population had an abnormal oral glucose tolerance test (OGTT). Thirty percent of those with an abnormal OGTT were less than 25 yr old. The specificity of a 1-h GCT (50-g carbohydrate load) using a threshold of either 140 or 150 mg/dl was compared with that of a 2-h specimen using a threshold of 118 mg/dl to determine whether the cost of screening could be reduced. One- and 2-h specimens were obtained in 347 of these women. A 34% reduction in the number of follow-up OGTTs required would have been achieved if a 2-h specimen had been used as the index instead of a 1-h specimen (P less than .05). As a result, the (direct and indirect) cost per patient identified with GDM would have declined 23.5%--from $866 to $662. No comment concerning the actual false-negative rate of either the 1- or 2-h GCT can be made because only select women underwent an OGTT. To assess the validity of the 2-h threshold, an OGTT was performed in an additional 190 women if either the 1- or 2-h screen was abnormal. The results were confirmatory: the 2-h screen would have reduced the cost per case identified by 32% in this small group. Screening on the basis of past medical history clearly lacked sensitivity and cost efficacy in comparison with the GCT and should be abandoned as a practice.

  16. MD-2 as the target of a novel small molecule, L6H21, in the attenuation of LPS-induced inflammatory response and sepsis

    PubMed Central

    Wang, Yi; Shan, Xiaoou; Chen, Gaozhi; Jiang, Lili; Wang, Zhe; Fang, Qilu; Liu, Xing; Wang, Jingying; Zhang, Yali; Wu, Wencan; Liang, Guang

    2015-01-01

    Background and Purpose Myeloid differentiation 2 (MD-2) recognizes LPS, which is required for TLR4 activation, and represents an attractive therapeutic target for severe inflammatory disorders. We previously found that a chalcone derivative, L6H21, could inhibit LPS-induced overexpression of TNF-α and IL-6 in macrophages. Here, we performed a series of biochemical experiments to investigate whether L6H21 specifically targets MD-2 and inhibits the interaction and signalling transduction of LPS-TLR4/MD-2. Experimental Approach The binding affinity of L6H21 to MD-2 protein was analysed using computer docking, surface plasmon resonance analysis, elisa, fluorescence measurements and flow cytometric analysis. The effects of L6H21 on MAPK and NF-κB signalling were determined using EMSA, fluorescence staining, Western blotting and immunoprecipitation. The anti-inflammatory effects of L6H21 were confirmed using elisa and RT-qPCR in vitro. The anti-inflammatory effects of L6H21 were also evaluated in septic C57BL/6 mice. Key Results Compound L6H21 inserted into the hydrophobic region of the MD-2 pocket, forming hydrogen bonds with Arg90 and Tyr102 in the MD-2 pocket. In vitro, L6H21 subsequently suppressed MAPK phosphorylation, NF-κB activation and cytokine expression in macrophages stimulated by LPS. In vivo, L6H21 pretreatment improved survival, prevented lung injury, decreased serum and hepatic cytokine levels in mice subjected to LPS. In addition, mice with MD-2 gene knockout were universally protected from the effects of LPS-induced septic shock. Conclusions and Implications Overall, this work demonstrated that the new chalcone derivative, L6H21, is a potential candidate for the treatment of sepsis. More importantly, the data confirmed that MD-2 is an important therapeutic target for inflammatory disorders. PMID:26076332

  17. Percolation bounds for decoding thresholds with correlated erasures in quantum LDPC codes

    NASA Astrophysics Data System (ADS)

    Hamilton, Kathleen; Pryadko, Leonid

    Correlations between errors can dramatically affect decoding thresholds, in some cases eliminating the threshold altogether. We analyze the existence of a threshold for quantum low-density parity-check (LDPC) codes in the case of correlated erasures. When erasures are positively correlated, the corresponding multi-variate Bernoulli distribution can be modeled in terms of cluster errors, where qubits in clusters of various size can be marked all at once. In a code family with distance scaling as a power law of the code length, erasures can be always corrected below percolation on a qubit adjacency graph associated with the code. We bound this correlated percolation transition by weighted (uncorrelated) percolation on a specially constructed cluster connectivity graph, and apply our recent results to construct several bounds for the latter. This research was supported in part by the NSF Grant PHY-1416578 and by the ARO Grant W911NF-14-1-0272.

  18. Lexical Threshold Revisited: Lexical Text Coverage, Learners' Vocabulary Size and Reading Comprehension

    ERIC Educational Resources Information Center

    Laufer, Batia; Ravenhorst-Kalovski, Geke C.

    2010-01-01

    We explore the relationship between second language (L2) learners' vocabulary size, lexical text coverage that their vocabulary provides and their reading comprehension. We also conceptualize "adequate reading comprehension" and look for the lexical threshold for such reading in terms of coverage and vocabulary size. Vocabulary size was…

  19. Écologie bactérienne de l'infection nosocomiale au service de réanimation de l'hôpital Laquintinie de Douala, Cameroun

    PubMed Central

    Njall, Clotilde; Adiogo, Dieudonné; Bita, André; Ateba, Noel; Sume, Gérald; Kollo, Basile; Binam, Fidèle; Tchoua, Romain

    2013-01-01

    Introduction L'objectif principal de notre étude était d'identifier les bactéries associées à l'infection nosocomiale, dans le service de réanimation, de l'hôpital Laquintinie de Douala en vue d'améliorer la prise en charge et diminuer la létalité. Méthodes Il s'agissait d'une étude transversale et descriptive, menée du 1er mars au 31 mai 2011.Tous les patients hospitalisés depuis au moins 48 h étaient inclus dans l’étude et ceux présentant une infection documentée à l'admission étaient exclus. L'analyse des donnés a été faite par le logiciel SPSS 16.Les tests de Khi deux pour la signification. Résultats La prévalence de l'infection nosocomiale était de 12%, elle concernait des personnes âgées de plus de 60 ans et présentant une infection urinaire dans 79% des cas. La létalité était de 72% pour une durée moyenne de séjour de 11,7 ± 12,1 jours. Les bactéries responsables étaient en majorité des bactéries gram positifs (BGN), dont E coli dans 23,1% et les cocci gram positifs(CGP), dans 15,4% des cas. Conclusion L’étude de la résistance aux antibiotiques, montre une multi résistance, dont il faut tenir compte en mettant en place une stratégie de prévention active. PMID:23785545

  20. The effects of salinity, pH, and dissolved organic matter on acute copper toxicity to the rotifer, Brachionus plicatilis ("L" strain).

    PubMed

    Arnold, W R; Diamond, R L; Smith, D S

    2010-08-01

    This paper presents data from original research for use in the development of a marine biotic ligand model and, ultimately, copper criteria for the protection of estuarine and marine organisms and their uses. Ten 48-h static acute (unfed) copper toxicity tests using the euryhaline rotifer Brachionus plicatilis ("L" strain) were performed to assess the effects of salinity, pH, and dissolved organic matter (measured as dissolved organic carbon; DOC) on median lethal dissolved copper concentrations (LC50). Reconstituted and natural saltwater samples were tested at seven salinities (6, 11, 13, 15, 20, 24, and 29 g/L), over a pH range of 6.8-8.6 and a range of dissolved organic carbon of <0.5-4.1 mg C/L. Water chemistry analyses (alkalinity, calcium, chloride, DOC, hardness, magnesium, potassium, sodium, salinity, and temperature) are presented for input parameters to the biotic ligand model. In stepwise multiple regression analysis of experimental results where salinity, pH, and DOC concentrations varied, copper toxicity was significantly related only to the dissolved organic matter content (pH and salinity not statistically retained; alpha=0.05). The relationship of the 48-h dissolved copper LC50 values and dissolved organic carbon concentrations was LC50 (microg Cu/L)=27.1xDOC (mg C/L)1.25; r2=0.94.