Sample records for label-free lc-ms analysis

  1. Bayesian Normalization Model for Label-Free Quantitative Analysis by LC-MS

    PubMed Central

    Nezami Ranjbar, Mohammad R.; Tadesse, Mahlet G.; Wang, Yue; Ressom, Habtom W.

    2016-01-01

    We introduce a new method for normalization of data acquired by liquid chromatography coupled with mass spectrometry (LC-MS) in label-free differential expression analysis. Normalization of LC-MS data is desired prior to subsequent statistical analysis to adjust variabilities in ion intensities that are not caused by biological differences but experimental bias. There are different sources of bias including variabilities during sample collection and sample storage, poor experimental design, noise, etc. In addition, instrument variability in experiments involving a large number of LC-MS runs leads to a significant drift in intensity measurements. Although various methods have been proposed for normalization of LC-MS data, there is no universally applicable approach. In this paper, we propose a Bayesian normalization model (BNM) that utilizes scan-level information from LC-MS data. Specifically, the proposed method uses peak shapes to model the scan-level data acquired from extracted ion chromatograms (EIC) with parameters considered as a linear mixed effects model. We extended the model into BNM with drift (BNMD) to compensate for the variability in intensity measurements due to long LC-MS runs. We evaluated the performance of our method using synthetic and experimental data. In comparison with several existing methods, the proposed BNM and BNMD yielded significant improvement. PMID:26357332

  2. LFQuant: a label-free fast quantitative analysis tool for high-resolution LC-MS/MS proteomics data.

    PubMed

    Zhang, Wei; Zhang, Jiyang; Xu, Changming; Li, Ning; Liu, Hui; Ma, Jie; Zhu, Yunping; Xie, Hongwei

    2012-12-01

    Database searching based methods for label-free quantification aim to reconstruct the peptide extracted ion chromatogram based on the identification information, which can limit the search space and thus make the data processing much faster. The random effect of the MS/MS sampling can be remedied by cross-assignment among different runs. Here, we present a new label-free fast quantitative analysis tool, LFQuant, for high-resolution LC-MS/MS proteomics data based on database searching. It is designed to accept raw data in two common formats (mzXML and Thermo RAW), and database search results from mainstream tools (MASCOT, SEQUEST, and X!Tandem), as input data. LFQuant can handle large-scale label-free data with fractionation such as SDS-PAGE and 2D LC. It is easy to use and provides handy user interfaces for data loading, parameter setting, quantitative analysis, and quantitative data visualization. LFQuant was compared with two common quantification software packages, MaxQuant and IDEAL-Q, on the replication data set and the UPS1 standard data set. The results show that LFQuant performs better than them in terms of both precision and accuracy, and consumes significantly less processing time. LFQuant is freely available under the GNU General Public License v3.0 at http://sourceforge.net/projects/lfquant/. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Chip-LC-MS for label-free profiling of human serum.

    PubMed

    Horvatovich, Peter; Govorukhina, Natalia I; Reijmers, Theo H; van der Zee, Ate G J; Suits, Frank; Bischoff, Rainer

    2007-12-01

    The discovery of biomarkers in easily accessible body fluids such as serum is one of the most challenging topics in proteomics requiring highly efficient separation and detection methodologies. Here, we present the application of a microfluidics-based LC-MS system (chip-LC-MS) to the label-free profiling of immunodepleted, trypsin-digested serum in comparison to conventional capillary LC-MS (cap-LC-MS). Both systems proved to have a repeatability of approximately 20% RSD for peak area, all sample preparation steps included, while repeatability of the LC-MS part by itself was less than 10% RSD for the chip-LC-MS system. Importantly, the chip-LC-MS system had a two times higher resolution in the LC dimension and resulted in a lower average charge state of the tryptic peptide ions generated in the ESI interface when compared to cap-LC-MS while requiring approximately 30 times less (~5 pmol) sample. In order to characterize both systems for their capability to find discriminating peptides in trypsin-digested serum samples, five out of ten individually prepared, identical sera were spiked with horse heart cytochrome c. A comprehensive data processing methodology was applied including 2-D smoothing, resolution reduction, peak picking, time alignment, and matching of the individual peak lists to create an aligned peak matrix amenable for statistical analysis. Statistical analysis by supervised classification and variable selection showed that both LC-MS systems could discriminate the two sample groups. However, the chip-LC-MS system allowed to assign 55% of the overall signal to selected peaks against 32% for the cap-LC-MS system.

  4. Quality evaluation of LC-MS/MS-based E. coli H antigen typing (MS-H) through label-free quantitative data analysis in a clinical sample setup.

    PubMed

    Cheng, Keding; Sloan, Angela; McCorrister, Stuart; Peterson, Lorea; Chui, Huixia; Drebot, Mike; Nadon, Celine; Knox, J David; Wang, Gehua

    2014-12-01

    The need for rapid and accurate H typing is evident during Escherichia coli outbreak situations. This study explores the transition of MS-H, a method originally developed for rapid H antigen typing of E. coli using LC-MS/MS of flagella digest of reference strains and some clinical strains, to E. coli isolates in clinical scenario through quantitative analysis and method validation. Motile and nonmotile strains were examined in batches to simulate clinical sample scenario. Various LC-MS/MS batch run procedures and MS-H typing rules were compared and summarized through quantitative analysis of MS-H data output for a standard method development. Label-free quantitative data analysis of MS-H typing was proven very useful for examining the quality of MS-H result and the effects of some sample carryovers from motile E. coli isolates. Based on this, a refined procedure and protein identification rule specific for clinical MS-H typing was established and validated. With LC-MS/MS batch run procedure and database search parameter unique for E. coli MS-H typing, the standard procedure maintained high accuracy and specificity in clinical situations, and its potential to be used in a clinical setting was clearly established. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. A Comparative Analysis of Computational Approaches to Relative Protein Quantification Using Peptide Peak Intensities in Label-free LC-MS Proteomics Experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matzke, Melissa M.; Brown, Joseph N.; Gritsenko, Marina A.

    2013-02-01

    Liquid chromatography coupled with mass spectrometry (LC-MS) is widely used to identify and quantify peptides in complex biological samples. In particular, label-free shotgun proteomics is highly effective for the identification of peptides and subsequently obtaining a global protein profile of a sample. As a result, this approach is widely used for discovery studies. Typically, the objective of these discovery studies is to identify proteins that are affected by some condition of interest (e.g. disease, exposure). However, for complex biological samples, label-free LC-MS proteomics experiments measure peptides and do not directly yield protein quantities. Thus, protein quantification must be inferred frommore » one or more measured peptides. In recent years, many computational approaches to relative protein quantification of label-free LC-MS data have been published. In this review, we examine the most commonly employed quantification approaches to relative protein abundance from peak intensity values, evaluate their individual merits, and discuss challenges in the use of the various computational approaches.« less

  6. Benchmarking quantitative label-free LC-MS data processing workflows using a complex spiked proteomic standard dataset.

    PubMed

    Ramus, Claire; Hovasse, Agnès; Marcellin, Marlène; Hesse, Anne-Marie; Mouton-Barbosa, Emmanuelle; Bouyssié, David; Vaca, Sebastian; Carapito, Christine; Chaoui, Karima; Bruley, Christophe; Garin, Jérôme; Cianférani, Sarah; Ferro, Myriam; Van Dorssaeler, Alain; Burlet-Schiltz, Odile; Schaeffer, Christine; Couté, Yohann; Gonzalez de Peredo, Anne

    2016-01-30

    Proteomic workflows based on nanoLC-MS/MS data-dependent-acquisition analysis have progressed tremendously in recent years. High-resolution and fast sequencing instruments have enabled the use of label-free quantitative methods, based either on spectral counting or on MS signal analysis, which appear as an attractive way to analyze differential protein expression in complex biological samples. However, the computational processing of the data for label-free quantification still remains a challenge. Here, we used a proteomic standard composed of an equimolar mixture of 48 human proteins (Sigma UPS1) spiked at different concentrations into a background of yeast cell lysate to benchmark several label-free quantitative workflows, involving different software packages developed in recent years. This experimental design allowed to finely assess their performances in terms of sensitivity and false discovery rate, by measuring the number of true and false-positive (respectively UPS1 or yeast background proteins found as differential). The spiked standard dataset has been deposited to the ProteomeXchange repository with the identifier PXD001819 and can be used to benchmark other label-free workflows, adjust software parameter settings, improve algorithms for extraction of the quantitative metrics from raw MS data, or evaluate downstream statistical methods. Bioinformatic pipelines for label-free quantitative analysis must be objectively evaluated in their ability to detect variant proteins with good sensitivity and low false discovery rate in large-scale proteomic studies. This can be done through the use of complex spiked samples, for which the "ground truth" of variant proteins is known, allowing a statistical evaluation of the performances of the data processing workflow. We provide here such a controlled standard dataset and used it to evaluate the performances of several label-free bioinformatics tools (including MaxQuant, Skyline, MFPaQ, IRMa-hEIDI and Scaffold) in

  7. Label-Free, LC-MS-Based Assays to Quantitate Small-Molecule Antagonist Binding to the Mammalian BLT1 Receptor.

    PubMed

    Chen, Xun; Stout, Steven; Mueller, Uwe; Boykow, George; Visconti, Richard; Siliphaivanh, Phieng; Spencer, Kerrie; Presland, Jeremy; Kavana, Michael; Basso, Andrea D; McLaren, David G; Myers, Robert W

    2017-08-01

    We have developed and validated label-free, liquid chromatography-mass spectrometry (LC-MS)-based equilibrium direct and competition binding assays to quantitate small-molecule antagonist binding to recombinant human and mouse BLT1 receptors expressed in HEK 293 cell membranes. Procedurally, these binding assays involve (1) equilibration of the BLT1 receptor and probe ligand, with or without a competitor; (2) vacuum filtration through cationic glass fiber filters to separate receptor-bound from free probe ligand; and (3) LC-MS analysis in selected reaction monitoring mode for bound probe ligand quantitation. Two novel, optimized probe ligands, compounds 1 and 2, were identified by screening 20 unlabeled BLT1 antagonists for direct binding. Saturation direct binding studies confirmed the high affinity, and dissociation studies established the rapid binding kinetics of probe ligands 1 and 2. Competition binding assays were established using both probe ligands, and the affinities of structurally diverse BLT1 antagonists were measured. Both binding assay formats can be executed with high specificity and sensitivity and moderate throughput (96-well plate format) using these approaches. This highly versatile, label-free method for studying ligand binding to membrane-associated receptors should find broad application as an alternative to traditional methods using labeled ligands.

  8. A New Algorithm Using Cross-Assignment for Label-Free Quantitation with LC/LTQ-FT MS

    PubMed Central

    Andreev, Victor P.; Li, Lingyun; Cao, Lei; Gu, Ye; Rejtar, Tomas; Wu, Shiaw-Lin; Karger, Barry L.

    2008-01-01

    A new algorithm is described for label-free quantitation of relative protein abundances across multiple complex proteomic samples. Q-MEND is based on the denoising and peak picking algorithm, MEND, previously developed in our laboratory. Q-MEND takes advantage of the high resolution and mass accuracy of the hybrid LTQFT MS mass spectrometer (or other high resolution mass spectrometers, such as a Q-TOF MS). The strategy, termed “cross-assignment”, is introduced to increase substantially the number of quantitated proteins. In this approach, all MS/MS identifications for the set of analyzed samples are combined into a master ID list, and then each LC/MS run is searched for the features that can be assigned to a specific identification from that master list. The reliability of quantitation is enhanced by quantitating separately all peptide charge states, along with a scoring procedure to filter out less reliable peptide abundance measurements. The effectiveness of Q-MEND is illustrated in the relative quantitative analysis of E.coli samples spiked with known amounts of non-E.coli protein digests. A mean quantitation accuracy of 7% and mean precision of 15% is demonstrated. Q-MEND can perform relative quantitation of a set of LC/MS datasets without manual intervention and can generate files compatible with the Guidelines for Proteomic Data Publication. PMID:17441747

  9. A new algorithm using cross-assignment for label-free quantitation with LC-LTQ-FT MS.

    PubMed

    Andreev, Victor P; Li, Lingyun; Cao, Lei; Gu, Ye; Rejtar, Tomas; Wu, Shiaw-Lin; Karger, Barry L

    2007-06-01

    A new algorithm is described for label-free quantitation of relative protein abundances across multiple complex proteomic samples. Q-MEND is based on the denoising and peak picking algorithm, MEND, previously developed in our laboratory. Q-MEND takes advantage of the high resolution and mass accuracy of the hybrid LTQ-FT MS mass spectrometer (or other high-resolution mass spectrometers, such as a Q-TOF MS). The strategy, termed "cross-assignment", is introduced to increase substantially the number of quantitated proteins. In this approach, all MS/MS identifications for the set of analyzed samples are combined into a master ID list, and then each LC-MS run is searched for the features that can be assigned to a specific identification from that master list. The reliability of quantitation is enhanced by quantitating separately all peptide charge states, along with a scoring procedure to filter out less reliable peptide abundance measurements. The effectiveness of Q-MEND is illustrated in the relative quantitative analysis of Escherichia coli samples spiked with known amounts of non-E. coli protein digests. A mean quantitation accuracy of 7% and mean precision of 15% is demonstrated. Q-MEND can perform relative quantitation of a set of LC-MS data sets without manual intervention and can generate files compatible with the Guidelines for Proteomic Data Publication.

  10. msCompare: A Framework for Quantitative Analysis of Label-free LC-MS Data for Comparative Candidate Biomarker Studies*

    PubMed Central

    Hoekman, Berend; Breitling, Rainer; Suits, Frank; Bischoff, Rainer; Horvatovich, Peter

    2012-01-01

    Data processing forms an integral part of biomarker discovery and contributes significantly to the ultimate result. To compare and evaluate various publicly available open source label-free data processing workflows, we developed msCompare, a modular framework that allows the arbitrary combination of different feature detection/quantification and alignment/matching algorithms in conjunction with a novel scoring method to evaluate their overall performance. We used msCompare to assess the performance of workflows built from modules of publicly available data processing packages such as SuperHirn, OpenMS, and MZmine and our in-house developed modules on peptide-spiked urine and trypsin-digested cerebrospinal fluid (CSF) samples. We found that the quality of results varied greatly among workflows, and interestingly, heterogeneous combinations of algorithms often performed better than the homogenous workflows. Our scoring method showed that the union of feature matrices of different workflows outperformed the original homogenous workflows in some cases. msCompare is open source software (https://trac.nbic.nl/mscompare), and we provide a web-based data processing service for our framework by integration into the Galaxy server of the Netherlands Bioinformatics Center (http://galaxy.nbic.nl/galaxy) to allow scientists to determine which combination of modules provides the most accurate processing for their particular LC-MS data sets. PMID:22318370

  11. IsoMS: automated processing of LC-MS data generated by a chemical isotope labeling metabolomics platform.

    PubMed

    Zhou, Ruokun; Tseng, Chiao-Li; Huan, Tao; Li, Liang

    2014-05-20

    A chemical isotope labeling or isotope coded derivatization (ICD) metabolomics platform uses a chemical derivatization method to introduce a mass tag to all of the metabolites having a common functional group (e.g., amine), followed by LC-MS analysis of the labeled metabolites. To apply this platform to metabolomics studies involving quantitative analysis of different groups of samples, automated data processing is required. Herein, we report a data processing method based on the use of a mass spectral feature unique to the chemical labeling approach, i.e., any differential-isotope-labeled metabolites are detected as peak pairs with a fixed mass difference in a mass spectrum. A software tool, IsoMS, has been developed to process the raw data generated from one or multiple LC-MS runs by peak picking, peak pairing, peak-pair filtering, and peak-pair intensity ratio calculation. The same peak pairs detected from multiple samples are then aligned to produce a CSV file that contains the metabolite information and peak ratios relative to a control (e.g., a pooled sample). This file can be readily exported for further data and statistical analysis, which is illustrated in an example of comparing the metabolomes of human urine samples collected before and after drinking coffee. To demonstrate that this method is reliable for data processing, five (13)C2-/(12)C2-dansyl labeled metabolite standards were analyzed by LC-MS. IsoMS was able to detect these metabolites correctly. In addition, in the analysis of a (13)C2-/(12)C2-dansyl labeled human urine, IsoMS detected 2044 peak pairs, and manual inspection of these peak pairs found 90 false peak pairs, representing a false positive rate of 4.4%. IsoMS for Windows running R is freely available for noncommercial use from www.mycompoundid.org/IsoMS.

  12. Label-Free LC-MS/MS Proteomic Analysis of Cerebrospinal Fluid Identifies Protein/Pathway Alterations and Candidate Biomarkers for Amyotrophic Lateral Sclerosis.

    PubMed

    Collins, Mahlon A; An, Jiyan; Hood, Brian L; Conrads, Thomas P; Bowser, Robert P

    2015-11-06

    Analysis of the cerebrospinal fluid (CSF) proteome has proven valuable to the study of neurodegenerative disorders. To identify new protein/pathway alterations and candidate biomarkers for amyotrophic lateral sclerosis (ALS), we performed comparative proteomic profiling of CSF from sporadic ALS (sALS), healthy control (HC), and other neurological disease (OND) subjects using label-free liquid chromatography-tandem mass spectrometry (LC-MS/MS). A total of 1712 CSF proteins were detected and relatively quantified by spectral counting. Levels of several proteins with diverse biological functions were significantly altered in sALS samples. Enrichment analysis was used to link these alterations to biological pathways, which were predominantly related to inflammation, neuronal activity, and extracellular matrix regulation. We then used our CSF proteomic profiles to create a support vector machines classifier capable of discriminating training set ALS from non-ALS (HC and OND) samples. Four classifier proteins, WD repeat-containing protein 63, amyloid-like protein 1, SPARC-like protein 1, and cell adhesion molecule 3, were identified by feature selection and externally validated. The resultant classifier distinguished ALS from non-ALS samples with 83% sensitivity and 100% specificity in an independent test set. Collectively, our results illustrate the utility of CSF proteomic profiling for identifying ALS protein/pathway alterations and candidate disease biomarkers.

  13. Large-Scale and Deep Quantitative Proteome Profiling Using Isobaric Labeling Coupled with Two-Dimensional LC-MS/MS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gritsenko, Marina A.; Xu, Zhe; Liu, Tao

    Comprehensive, quantitative information on abundances of proteins and their post-translational modifications (PTMs) can potentially provide novel biological insights into diseases pathogenesis and therapeutic intervention. Herein, we introduce a quantitative strategy utilizing isobaric stable isotope-labelling techniques combined with two-dimensional liquid chromatography-tandem mass spectrometry (2D-LC-MS/MS) for large-scale, deep quantitative proteome profiling of biological samples or clinical specimens such as tumor tissues. The workflow includes isobaric labeling of tryptic peptides for multiplexed and accurate quantitative analysis, basic reversed-phase LC fractionation and concatenation for reduced sample complexity, and nano-LC coupled to high resolution and high mass accuracy MS analysis for high confidence identification andmore » quantification of proteins. This proteomic analysis strategy has been successfully applied for in-depth quantitative proteomic analysis of tumor samples, and can also be used for integrated proteome and PTM characterization, as well as comprehensive quantitative proteomic analysis across samples from large clinical cohorts.« less

  14. Large-Scale and Deep Quantitative Proteome Profiling Using Isobaric Labeling Coupled with Two-Dimensional LC-MS/MS.

    PubMed

    Gritsenko, Marina A; Xu, Zhe; Liu, Tao; Smith, Richard D

    2016-01-01

    Comprehensive, quantitative information on abundances of proteins and their posttranslational modifications (PTMs) can potentially provide novel biological insights into diseases pathogenesis and therapeutic intervention. Herein, we introduce a quantitative strategy utilizing isobaric stable isotope-labeling techniques combined with two-dimensional liquid chromatography-tandem mass spectrometry (2D-LC-MS/MS) for large-scale, deep quantitative proteome profiling of biological samples or clinical specimens such as tumor tissues. The workflow includes isobaric labeling of tryptic peptides for multiplexed and accurate quantitative analysis, basic reversed-phase LC fractionation and concatenation for reduced sample complexity, and nano-LC coupled to high resolution and high mass accuracy MS analysis for high confidence identification and quantification of proteins. This proteomic analysis strategy has been successfully applied for in-depth quantitative proteomic analysis of tumor samples and can also be used for integrated proteome and PTM characterization, as well as comprehensive quantitative proteomic analysis across samples from large clinical cohorts.

  15. Comparative label-free LC-MS/MS analysis of colorectal adenocarcinoma and metastatic cells treated with 5-fluorouracil.

    PubMed

    Bauer, Kerry M; Lambert, Paul A; Hummon, Amanda B

    2012-06-01

    A label-free mass spectrometric strategy was used to examine the effect of 5-fluorouracil (5-FU) on the primary and metastatic colon carcinoma cell lines, SW480 and SW620, with and without treatment. 5-FU is the most common chemotherapeutic treatment for colon cancer. Pooled biological replicates were analyzed by nanoLC-MS/MS and protein quantification was determined via spectral counting. Phenotypic and proteomic changes were evident and often similar in both cell lines. The SW620 cells were more resistant to 5-FU treatment, with an IC(50) 2.7-fold higher than that for SW480. In addition, both cell lines showed pronounced abundance changes in pathways relating to antioxidative stress response and cell adhesion remodeling due to 5-FU treatment. For example, the detoxification enzyme NQO1 was increased with treatment in both cell lines, while disparate members of the peroxiredoxin family, PRDX2 or PRDX5 and PRDX6, were elevated with 5-FU exposure in either SW480 or SW620, respectively. Cell adhesion-associated proteins CTNNB1 and RhoA showed decreased expression with 5-FU treatment in both cell lines. The differential quantitative response in the proteomes of these patient-matched cell lines to drug treatment underscores the subtle molecular differences separating primary and metastatic cancer cells. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Development of High-Performance Chemical Isotope Labeling LC-MS for Profiling the Carbonyl Submetabolome.

    PubMed

    Zhao, Shuang; Dawe, Margot; Guo, Kevin; Li, Liang

    2017-06-20

    Metabolites containing a carbonyl group represent several important classes of molecules including various forms of ketones and aldehydes such as steroids and sugars. We report a high-performance chemical isotope labeling (CIL) LC-MS method for profiling the carbonyl submetabolome with high coverage and high accuracy and precision of relative quantification. This method is based on the use of dansylhydrazine (DnsHz) labeling of carbonyl metabolites to change their chemical and physical properties to such an extent that the labeled metabolites can be efficiently separated by reversed phase LC and ionized by electrospray ionization MS. In the analysis of six standards representing different carbonyl classes, acetaldehyde could be ionized only after labeling and MS signals were significantly increased for other 5 standards with an enhancement factor ranging from ∼15-fold for androsterone to ∼940-fold for 2-butanone. Differential 12 C- and 13 C-DnsHz labeling was developed for quantifying metabolic differences in comparative samples where individual samples were separately labeled with 12 C-labeling and spiked with a 13 C-labeled pooled sample, followed by LC-MS analysis, peak pair picking, and peak intensity ratio measurement. In the replicate analysis of a 1:1 12 C-/ 13 C-labeled human urine mixture (n = 6), an average of 2030 ± 39 pairs per run were detected with 1737 pairs in common, indicating the possibility of detecting a large number of carbonyl metabolites as well as high reproducibility of peak pair detection. The average RSD of the peak pair ratios was 7.6%, and 95.6% of the pairs had a RSD value of less than 20%, demonstrating high precision for peak ratio measurement. In addition, the ratios of most peak pairs were close to the expected value of 1.0 (e.g., 95.5% of them had ratios of between 0.67 and 1.5), showing the high accuracy of the method. For metabolite identification, a library of DnsHz-labeled standards was constructed, including 78 carbonyl

  17. Differential Plasma Glycoproteome of p19 Skin Cancer Mouse Model Using the Corra Label-Free LC-MS Proteomics Platform.

    PubMed

    Letarte, Simon; Brusniak, Mi-Youn; Campbell, David; Eddes, James; Kemp, Christopher J; Lau, Hollis; Mueller, Lukas; Schmidt, Alexander; Shannon, Paul; Kelly-Spratt, Karen S; Vitek, Olga; Zhang, Hui; Aebersold, Ruedi; Watts, Julian D

    2008-12-01

    A proof-of-concept demonstration of the use of label-free quantitative glycoproteomics for biomarker discovery workflow is presented here, using a mouse model for skin cancer as an example. Blood plasma was collected from 10 control mice, and 10 mice having a mutation in the p19(ARF) gene, conferring them high propensity to develop skin cancer after carcinogen exposure. We enriched for N-glycosylated plasma proteins, ultimately generating deglycosylated forms of the modified tryptic peptides for liquid chromatography mass spectrometry (LC-MS) analyses. LC-MS runs for each sample were then performed with a view to identifying proteins that were differentially abundant between the two mouse populations. We then used a recently developed computational framework, Corra, to perform peak picking and alignment, and to compute the statistical significance of any observed changes in individual peptide abundances. Once determined, the most discriminating peptide features were then fragmented and identified by tandem mass spectrometry with the use of inclusion lists. We next assessed the identified proteins to see if there were sets of proteins indicative of specific biological processes that correlate with the presence of disease, and specifically cancer, according to their functional annotations. As expected for such sick animals, many of the proteins identified were related to host immune response. However, a significant number of proteins also directly associated with processes linked to cancer development, including proteins related to the cell cycle, localisation, trasport, and cell death. Additional analysis of the same samples in profiling mode, and in triplicate, confirmed that replicate MS analysis of the same plasma sample generated less variation than that observed between plasma samples from different individuals, demonstrating that the reproducibility of the LC-MS platform was sufficient for this application. These results thus show that an LC-MS-based workflow

  18. Visualization of LC-MS/MS proteomics data in MaxQuant.

    PubMed

    Tyanova, Stefka; Temu, Tikira; Carlson, Arthur; Sinitcyn, Pavel; Mann, Matthias; Cox, Juergen

    2015-04-01

    Modern software platforms enable the analysis of shotgun proteomics data in an automated fashion resulting in high quality identification and quantification results. Additional understanding of the underlying data can be gained with the help of advanced visualization tools that allow for easy navigation through large LC-MS/MS datasets potentially consisting of terabytes of raw data. The updated MaxQuant version has a map navigation component that steers the users through mass and retention time-dependent mass spectrometric signals. It can be used to monitor a peptide feature used in label-free quantification over many LC-MS runs and visualize it with advanced 3D graphic models. An expert annotation system aids the interpretation of the MS/MS spectra used for the identification of these peptide features. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. ComplexQuant: high-throughput computational pipeline for the global quantitative analysis of endogenous soluble protein complexes using high resolution protein HPLC and precision label-free LC/MS/MS.

    PubMed

    Wan, Cuihong; Liu, Jian; Fong, Vincent; Lugowski, Andrew; Stoilova, Snejana; Bethune-Waddell, Dylan; Borgeson, Blake; Havugimana, Pierre C; Marcotte, Edward M; Emili, Andrew

    2013-04-09

    The experimental isolation and characterization of stable multi-protein complexes are essential to understanding the molecular systems biology of a cell. To this end, we have developed a high-throughput proteomic platform for the systematic identification of native protein complexes based on extensive fractionation of soluble protein extracts by multi-bed ion exchange high performance liquid chromatography (IEX-HPLC) combined with exhaustive label-free LC/MS/MS shotgun profiling. To support these studies, we have built a companion data analysis software pipeline, termed ComplexQuant. Proteins present in the hundreds of fractions typically collected per experiment are first identified by exhaustively interrogating MS/MS spectra using multiple database search engines within an integrative probabilistic framework, while accounting for possible post-translation modifications. Protein abundance is then measured across the fractions based on normalized total spectral counts and precursor ion intensities using a dedicated tool, PepQuant. This analysis allows co-complex membership to be inferred based on the similarity of extracted protein co-elution profiles. Each computational step has been optimized for processing large-scale biochemical fractionation datasets, and the reliability of the integrated pipeline has been benchmarked extensively. This article is part of a Special Issue entitled: From protein structures to clinical applications. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Differential Plasma Glycoproteome of p19ARF Skin Cancer Mouse Model Using the Corra Label-Free LC-MS Proteomics Platform

    PubMed Central

    Letarte, Simon; Brusniak, Mi-Youn; Campbell, David; Eddes, James; Kemp, Christopher J.; Lau, Hollis; Mueller, Lukas; Schmidt, Alexander; Shannon, Paul; Kelly-Spratt, Karen S.; Vitek, Olga; Zhang, Hui; Aebersold, Ruedi; Watts, Julian D.

    2010-01-01

    A proof-of-concept demonstration of the use of label-free quantitative glycoproteomics for biomarker discovery workflow is presented here, using a mouse model for skin cancer as an example. Blood plasma was collected from 10 control mice, and 10 mice having a mutation in the p19ARF gene, conferring them high propensity to develop skin cancer after carcinogen exposure. We enriched for N-glycosylated plasma proteins, ultimately generating deglycosylated forms of the modified tryptic peptides for liquid chromatography mass spectrometry (LC-MS) analyses. LC-MS runs for each sample were then performed with a view to identifying proteins that were differentially abundant between the two mouse populations. We then used a recently developed computational framework, Corra, to perform peak picking and alignment, and to compute the statistical significance of any observed changes in individual peptide abundances. Once determined, the most discriminating peptide features were then fragmented and identified by tandem mass spectrometry with the use of inclusion lists. We next assessed the identified proteins to see if there were sets of proteins indicative of specific biological processes that correlate with the presence of disease, and specifically cancer, according to their functional annotations. As expected for such sick animals, many of the proteins identified were related to host immune response. However, a significant number of proteins also directly associated with processes linked to cancer development, including proteins related to the cell cycle, localisation, trasport, and cell death. Additional analysis of the same samples in profiling mode, and in triplicate, confirmed that replicate MS analysis of the same plasma sample generated less variation than that observed between plasma samples from different individuals, demonstrating that the reproducibility of the LC-MS platform was sufficient for this application. These results thus show that an LC-MS-based workflow

  1. Urinary amino acid analysis: a comparison of iTRAQ-LC-MS/MS, GC-MS, and amino acid analyzer.

    PubMed

    Kaspar, Hannelore; Dettmer, Katja; Chan, Queenie; Daniels, Scott; Nimkar, Subodh; Daviglus, Martha L; Stamler, Jeremiah; Elliott, Paul; Oefner, Peter J

    2009-07-01

    Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) of propyl chloroformate and iTRAQ derivatized amino acids, respectively, to conventional amino acid analysis. The GC-MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC-MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC-MS, and iTRAQ-LC-MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27+/-5.22, 21.18+/-10.94, and 18.34+/-14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39+/-5.35, 6.23+/-3.84, and 35.37+/-29.42. Both GC-MS and iTRAQ-LC-MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines.

  2. Development of high-performance chemical isotope labeling LC-MS for profiling the human fecal metabolome.

    PubMed

    Xu, Wei; Chen, Deying; Wang, Nan; Zhang, Ting; Zhou, Ruokun; Huan, Tao; Lu, Yingfeng; Su, Xiaoling; Xie, Qing; Li, Liang; Li, Lanjuan

    2015-01-20

    Human fecal samples contain endogenous human metabolites, gut microbiota metabolites, and other compounds. Profiling the fecal metabolome can produce metabolic information that may be used not only for disease biomarker discovery, but also for providing an insight about the relationship of the gut microbiome and human health. In this work, we report a chemical isotope labeling liquid chromatography-mass spectrometry (LC-MS) method for comprehensive and quantitative analysis of the amine- and phenol-containing metabolites in fecal samples. Differential (13)C2/(12)C2-dansyl labeling of the amines and phenols was used to improve LC separation efficiency and MS detection sensitivity. Water, methanol, and acetonitrile were examined as an extraction solvent, and a sequential water-acetonitrile extraction method was found to be optimal. A step-gradient LC-UV setup and a fast LC-MS method were evaluated for measuring the total concentration of dansyl labeled metabolites that could be used for normalizing the sample amounts of individual samples for quantitative metabolomics. Knowing the total concentration was also useful for optimizing the sample injection amount into LC-MS to maximize the number of metabolites detectable while avoiding sample overloading. For the first time, dansylation isotope labeling LC-MS was performed in a simple time-of-flight mass spectrometer, instead of high-end equipment, demonstrating the feasibility of using a low-cost instrument for chemical isotope labeling metabolomics. The developed method was applied for profiling the amine/phenol submetabolome of fecal samples collected from three families. An average of 1785 peak pairs or putative metabolites were found from a 30 min LC-MS run. From 243 LC-MS runs of all the fecal samples, a total of 6200 peak pairs were detected. Among them, 67 could be positively identified based on the mass and retention time match to a dansyl standard library, while 581 and 3197 peak pairs could be putatively

  3. A Simple and Sensitive LC-MS/MS Method for the Determination of Free 8-Hydroxy-2'-Deoxyguanosine in Human Urine

    NASA Technical Reports Server (NTRS)

    Wang, Zuwei; Smith, Scott M.

    2016-01-01

    Urinary free 8-hydroxy-2'-deoxyguanosine (8OHdG), an oxidized product of DNA, and is frequently chosen as a biomarker of oxidative stress in humans, including studies of oxidative DNA damage during space flight. It is challenging to accurately and efficiently quantify urinary free 8OHdG in large scale human studies. LC-MS/MS is emerging as a preferable analytical technique owing its high sensitivity, selectivity and efficiency, compared to some traditional methods such as ELISA and HPLC. A simple and sensitive LC-MS/MS method has been developed for the determination of free 8OHdG in human urine. Sample preparation was done by solid phase extraction with a Waters Oasis HLB 96 well plate. A Waters Alliance 2795 HT Separation Module combined with a Quattro Micro tandem mass spectrometer was used as the LC-MS/MS system. The runtime of one injection can be less than 5 minutes using a reversed phase C18 column and an isocratic flow of methanol/water. ESI positive ions were quantified in the multiple reaction modes (MRM) using m/z 284 yields 168 for 8OHdG and m/z 289 yields173 for stable isotope labeled internal standard [(15)N5] 8OHdG. With this method for 8OHdG, a lower limit of quantitation of 1.0 nM (0.28 ng/mL) has been achieved using 100 microliter urine sample. The analytical range is between 1.0 and 100 nM with a correlation coefficient greater than or equal to 0.99. Good reproducibility can be obtained with intra-assay and inter-assay CVs less than or equal to 10% for 8OHdG spiked urine QC samples. This method can be used in high-throughput routine analysis of free 8OHdG in human urine.

  4. Urinary Amino Acid Analysis: A Comparison of iTRAQ®-LC-MS/MS, GC-MS, and Amino Acid Analyzer

    PubMed Central

    Kaspar, Hannelore; Dettmer, Katja; Chan, Queenie; Daniels, Scott; Nimkar, Subodh; Daviglus, Martha L.; Stamler, Jeremiah; Elliott, Paul; Oefner, Peter J.

    2009-01-01

    Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) of propyl chloroformate and iTRAQ® derivatized amino acids, respectively, to conventional amino acid analysis. The GC-MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC-MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ® tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC-MS, and iTRAQ®-LC-MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27±5.22, 21.18±10.94, and 18.34±14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39±5.35, 6.23±3.84, and 35.37±29.42. Both GC-MS and iTRAQ®-LC-MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines. PMID:19481989

  5. Quantification of Free Phenytoin by Liquid Chromatography Tandem Mass Spectrometry (LC/MS/MS).

    PubMed

    Peat, Judy; Frazee, Clint; Garg, Uttam

    2016-01-01

    Phenytoin (diphenylhydantoin) is an anticonvulsant drug that has been used for decades for the treatment of many types of seizures. The drug is highly protein bound and measurement of free-active form of the drug is warranted particularly in patients with conditions that can affect drug protein binding. Here, we describe a LC/MS/MS method for the measurement of free phenytoin. Free drug is separated by ultrafiltration of serum or plasma. Ultrafiltrate is treated with acetonitrile containing internal standard phenytoin d-10 to precipitate proteins. The mixture is centrifuged and supernatant is injected onto LC-MS-MS, and analyzed using multiple reaction monitoring. This method is linear from 0.1 to 4.0 μg/mL and does not demonstrate any significant ion suppression or enhancement.

  6. Sensitivity of GC-EI/MS, GC-EI/MS/MS, LC-ESI/MS/MS, LC-Ag(+) CIS/MS/MS, and GC-ESI/MS/MS for analysis of anabolic steroids in doping control.

    PubMed

    Cha, Eunju; Kim, Sohee; Kim, Ho Jun; Lee, Kang Mi; Kim, Ki Hun; Kwon, Oh-Seung; Lee, Jaeick

    2015-01-01

    This study compared the sensitivity of various separation and ionization methods, including gas chromatography with an electron ionization source (GC-EI), liquid chromatography with an electrospray ionization source (LC-ESI), and liquid chromatography with a silver ion coordination ion spray source (LC-Ag(+) CIS), coupled to a mass spectrometer (MS) for steroid analysis. Chromatographic conditions, mass spectrometric transitions, and ion source parameters were optimized. The majority of steroids in GC-EI/MS/MS and LC-Ag(+) CIS/MS/MS analysis showed higher sensitivities than those obtained with other analytical methods. The limits of detection (LODs) of 65 steroids by GC-EI/MS/MS, 68 steroids by LC-Ag(+) CIS/MS/MS, 56 steroids by GC-EI/MS, 54 steroids by LC-ESI/MS/MS, and 27 steroids by GC-ESI/MS/MS were below cut-off value of 2.0 ng/mL. LODs of steroids that formed protonated ions in LC-ESI/MS/MS analysis were all lower than the cut-off value. Several steroids such as unconjugated C3-hydroxyl with C17-hydroxyl structure showed higher sensitivities in GC-EI/MS/MS analysis relative to those obtained using the LC-based methods. The steroids containing 4, 9, 11-triene structures showed relatively poor sensitivities in GC-EI/MS and GC-ESI/MS/MS analysis. The results of this study provide information that may be useful for selecting suitable analytical methods for confirmatory analysis of steroids. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Shotgun proteomics of plant plasma membrane and microdomain proteins using nano-LC-MS/MS.

    PubMed

    Takahashi, Daisuke; Li, Bin; Nakayama, Takato; Kawamura, Yukio; Uemura, Matsuo

    2014-01-01

    Shotgun proteomics allows the comprehensive analysis of proteins extracted from plant cells, subcellular organelles, and membranes. Previously, two-dimensional gel electrophoresis-based proteomics was used for mass spectrometric analysis of plasma membrane proteins. In order to get comprehensive proteome profiles of the plasma membrane including highly hydrophobic proteins with a number of transmembrane domains, a mass spectrometry-based shotgun proteomics method using nano-LC-MS/MS for proteins from the plasma membrane proteins and plasma membrane microdomain fraction is described. The results obtained are easily applicable to label-free protein semiquantification.

  8. Multiple reaction monitoring with multistage fragmentation (MRM3) detection enhances selectivity for LC-MS/MS analysis of plasma free metanephrines.

    PubMed

    Wright, Michael J; Thomas, Rebecca L; Stanford, Phoebe E; Horvath, Andrea R

    2015-03-01

    LC-MS/MS with multiple reaction monitoring (MRM) is a powerful tool for quantifying target analytes in complex matrices. However, the technique lacks selectivity when plasma free metanephrines are measured. We propose the use of multistage fragmentation (MRM(3)) to improve the analytical selectivity of plasma free metanephrine measurement. Metanephrines were extracted from plasma with weak cation exchange solid-phase extraction before separation by hydrophilic interaction liquid chromatography. We quantified normetanephrine and metanephrine by either MRM or MRM(3) transitions m/z 166→134→79 and m/z 180→149→121, respectively. Over a 6-month period, approximately 1% (n = 21) of patient samples showed uncharacterized coeluting substances that interfered with the routine assay, resulting in an inability to report results. Quantification with MRM(3) removed these interferences and enabled measurement of the target compounds. For patient samples unaffected by interferences, Deming regression analysis demonstrated a correlation between MRM(3) and MRM methods of y = 1.00x - 0.00 nmol/L for normetanephrine and y = 0.99x + 0.03 nmol/L for metanephrine. Between the MRM(3) method and the median of all LC-MS/MS laboratories enrolled in a quality assurance program, the correlations were y = 0.97x + 0.03 nmol/L for normetanephrine and y = 1.03x - 0.04 nmol/L for metanephrine. Imprecision for the MRM(3) method was 6.2%-7.0% for normetanephrine and 6.1%-9.9% for metanephrine (n = 10). The lower limits of quantification for the MRM(3) method were 0.20 nmol/L for normetanephrine and 0.16 nmol/L for metanephrine. The use of MRM(3) technology improves the analytical selectivity of plasma free metanephrine quantification by LC-MS/MS while demonstrating sufficient analytical sensitivity and imprecision. © 2014 American Association for Clinical Chemistry.

  9. Reductive chemical release of N-glycans as 1-amino-alditols and subsequent 9-fluorenylmethyloxycarbonyl labeling for MS and LC/MS analysis.

    PubMed

    Wang, Chengjian; Qiang, Shan; Jin, Wanjun; Song, Xuezheng; Zhang, Ying; Huang, Linjuan; Wang, Zhongfu

    2018-06-06

    Glycoproteins play pivotal roles in a series of biological processes and their glycosylation patterns need to be structurally and functionally characterized. However, the lack of versatile methods to release N-glycans as functionalized forms has been undermining glycomics studies. Here a novel method is developed for dissociation of N-linked glycans from glycoproteins for analysis by MS and online LC/MS. This new method employs aqueous ammonia solution containing NaBH 3 CN as the reaction medium to release glycans from glycoproteins as 1-amino-alditol forms. The released glycans are conveniently labeled with 9-fluorenylmethyloxycarbonyl (Fmoc) and analyzed by ESI-MS and online LC/MS. Using the method, the neutral and acidic N-glycans were successfully released without peeling degradation of the core α-1,3-fucosylated structure or detectable de-N-acetylation, revealing its general applicability to various types of N-glycans. The Fmoc-derivatized N-glycans derived from chicken ovalbumin, Fagopyrum esculentum Moench Pollen and FBS were successfully analyzed by online LC/MS to distinguish isomers. The 1-amino-alditols were also permethylated to form quaternary ammonium cations at the reducing end, which enhance the MS sensitivity and are compatible with sequential multi-stage mass spectrometry (MS n ) fragmentation for glycan sequencing. The Fmoc-labeled N-glycans were further permethylated to produce methylated carbamates for determination of branches and linkages by sequential MS n fragmentation. N-Glycosylation represents one of the most common post-translational modification forms and plays pivotal roles in the structural and functional regulation of proteins in various biological activities, relating closely to human health and diseases. As a type of informational molecule, the N-glycans of glycoproteins participate directly in the molecular interactions between glycan epitopes and their corresponding protein receptors. Detailed structural and functional

  10. Corra: Computational framework and tools for LC-MS discovery and targeted mass spectrometry-based proteomics

    PubMed Central

    Brusniak, Mi-Youn; Bodenmiller, Bernd; Campbell, David; Cooke, Kelly; Eddes, James; Garbutt, Andrew; Lau, Hollis; Letarte, Simon; Mueller, Lukas N; Sharma, Vagisha; Vitek, Olga; Zhang, Ning; Aebersold, Ruedi; Watts, Julian D

    2008-01-01

    Background Quantitative proteomics holds great promise for identifying proteins that are differentially abundant between populations representing different physiological or disease states. A range of computational tools is now available for both isotopically labeled and label-free liquid chromatography mass spectrometry (LC-MS) based quantitative proteomics. However, they are generally not comparable to each other in terms of functionality, user interfaces, information input/output, and do not readily facilitate appropriate statistical data analysis. These limitations, along with the array of choices, present a daunting prospect for biologists, and other researchers not trained in bioinformatics, who wish to use LC-MS-based quantitative proteomics. Results We have developed Corra, a computational framework and tools for discovery-based LC-MS proteomics. Corra extends and adapts existing algorithms used for LC-MS-based proteomics, and statistical algorithms, originally developed for microarray data analyses, appropriate for LC-MS data analysis. Corra also adapts software engineering technologies (e.g. Google Web Toolkit, distributed processing) so that computationally intense data processing and statistical analyses can run on a remote server, while the user controls and manages the process from their own computer via a simple web interface. Corra also allows the user to output significantly differentially abundant LC-MS-detected peptide features in a form compatible with subsequent sequence identification via tandem mass spectrometry (MS/MS). We present two case studies to illustrate the application of Corra to commonly performed LC-MS-based biological workflows: a pilot biomarker discovery study of glycoproteins isolated from human plasma samples relevant to type 2 diabetes, and a study in yeast to identify in vivo targets of the protein kinase Ark1 via phosphopeptide profiling. Conclusion The Corra computational framework leverages computational innovation to

  11. Experimental design and data-analysis in label-free quantitative LC/MS proteomics: A tutorial with MSqRob.

    PubMed

    Goeminne, Ludger J E; Gevaert, Kris; Clement, Lieven

    2018-01-16

    Label-free shotgun proteomics is routinely used to assess proteomes. However, extracting relevant information from the massive amounts of generated data remains difficult. This tutorial provides a strong foundation on analysis of quantitative proteomics data. We provide key statistical concepts that help researchers to design proteomics experiments and we showcase how to analyze quantitative proteomics data using our recent free and open-source R package MSqRob, which was developed to implement the peptide-level robust ridge regression method for relative protein quantification described by Goeminne et al. MSqRob can handle virtually any experimental proteomics design and outputs proteins ordered by statistical significance. Moreover, its graphical user interface and interactive diagnostic plots provide easy inspection and also detection of anomalies in the data and flaws in the data analysis, allowing deeper assessment of the validity of results and a critical review of the experimental design. Our tutorial discusses interactive preprocessing, data analysis and visualization of label-free MS-based quantitative proteomics experiments with simple and more complex designs. We provide well-documented scripts to run analyses in bash mode on GitHub, enabling the integration of MSqRob in automated pipelines on cluster environments (https://github.com/statOmics/MSqRob). The concepts outlined in this tutorial aid in designing better experiments and analyzing the resulting data more appropriately. The two case studies using the MSqRob graphical user interface will contribute to a wider adaptation of advanced peptide-based models, resulting in higher quality data analysis workflows and more reproducible results in the proteomics community. We also provide well-documented scripts for experienced users that aim at automating MSqRob on cluster environments. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Evaluation of the potential use of hybrid LC-MS/MS for active drug quantification applying the 'free analyte QC concept'.

    PubMed

    Jordan, Gregor; Onami, Ichio; Heinrich, Julia; Staack, Roland F

    2017-11-01

    Assessment of active drug exposure of biologics may be crucial for drug development. Typically, ligand-binding assay methods are used to provide free/active drug concentrations. To what extent hybrid LC-MS/MS procedures enable correct 'active' drug quantification is currently under consideration. Experimental & results: The relevance of appropriate extraction condition was evaluated by a hybrid target capture immuno-affinity LC-MS/MS method using total and free/active quality controls (QCs). The rapid extraction (10 min) provided correct results, whereas overnight incubation resulted in significant overestimation of the free/active drug (monclonal antibody) concentration. Conventional total QCs were inappropriate to determine optimal method conditions in contrast to free/active QCs. The 'free/active analyte QC concept' enables development of appropriate extraction conditions for correct active drug quantification by hybrid LC-MS/MS.

  13. LC-MS data processing with MAVEN: a metabolomic analysis and visualization engine.

    PubMed

    Clasquin, Michelle F; Melamud, Eugene; Rabinowitz, Joshua D

    2012-03-01

    MAVEN is an open-source software program for interactive processing of LC-MS-based metabolomics data. MAVEN enables rapid and reliable metabolite quantitation from multiple reaction monitoring data or high-resolution full-scan mass spectrometry data. It automatically detects and reports peak intensities for isotope-labeled metabolites. Menu-driven, click-based navigation allows visualization of raw and analyzed data. Here we provide a User Guide for MAVEN. Step-by-step instructions are provided for data import, peak alignment across samples, identification of metabolites that differ strongly between biological conditions, quantitation and visualization of isotope-labeling patterns, and export of tables of metabolite-specific peak intensities. Together, these instructions describe a workflow that allows efficient processing of raw LC-MS data into a form ready for biological analysis.

  14. Preprocessing and Analysis of LC-MS-Based Proteomic Data

    PubMed Central

    Tsai, Tsung-Heng; Wang, Minkun; Ressom, Habtom W.

    2016-01-01

    Liquid chromatography coupled with mass spectrometry (LC-MS) has been widely used for profiling protein expression levels. This chapter is focused on LC-MS data preprocessing, which is a crucial step in the analysis of LC-MS based proteomics. We provide a high-level overview, highlight associated challenges, and present a step-by-step example for analysis of data from LC-MS based untargeted proteomic study. Furthermore, key procedures and relevant issues with the subsequent analysis by multiple reaction monitoring (MRM) are discussed. PMID:26519169

  15. A Proof of Concept to Bridge the Gap between Mass Spectrometry Imaging, Protein Identification and Relative Quantitation: MSI~LC-MS/MS-LF.

    PubMed

    Théron, Laëtitia; Centeno, Delphine; Coudy-Gandilhon, Cécile; Pujos-Guillot, Estelle; Astruc, Thierry; Rémond, Didier; Barthelemy, Jean-Claude; Roche, Frédéric; Feasson, Léonard; Hébraud, Michel; Béchet, Daniel; Chambon, Christophe

    2016-10-26

    Mass spectrometry imaging (MSI) is a powerful tool to visualize the spatial distribution of molecules on a tissue section. The main limitation of MALDI-MSI of proteins is the lack of direct identification. Therefore, this study focuses on a MSI~LC-MS/MS-LF workflow to link the results from MALDI-MSI with potential peak identification and label-free quantitation, using only one tissue section. At first, we studied the impact of matrix deposition and laser ablation on protein extraction from the tissue section. Then, we did a back-correlation of the m / z of the proteins detected by MALDI-MSI to those identified by label-free quantitation. This allowed us to compare the label-free quantitation of proteins obtained in LC-MS/MS with the peak intensities observed in MALDI-MSI. We managed to link identification to nine peaks observed by MALDI-MSI. The results showed that the MSI~LC-MS/MS-LF workflow (i) allowed us to study a representative muscle proteome compared to a classical bottom-up workflow; and (ii) was sparsely impacted by matrix deposition and laser ablation. This workflow, performed as a proof-of-concept, suggests that a single tissue section can be used to perform MALDI-MSI and protein extraction, identification, and relative quantitation.

  16. A Proof of Concept to Bridge the Gap between Mass Spectrometry Imaging, Protein Identification and Relative Quantitation: MSI~LC-MS/MS-LF

    PubMed Central

    Théron, Laëtitia; Centeno, Delphine; Coudy-Gandilhon, Cécile; Pujos-Guillot, Estelle; Astruc, Thierry; Rémond, Didier; Barthelemy, Jean-Claude; Roche, Frédéric; Feasson, Léonard; Hébraud, Michel; Béchet, Daniel; Chambon, Christophe

    2016-01-01

    Mass spectrometry imaging (MSI) is a powerful tool to visualize the spatial distribution of molecules on a tissue section. The main limitation of MALDI-MSI of proteins is the lack of direct identification. Therefore, this study focuses on a MSI~LC-MS/MS-LF workflow to link the results from MALDI-MSI with potential peak identification and label-free quantitation, using only one tissue section. At first, we studied the impact of matrix deposition and laser ablation on protein extraction from the tissue section. Then, we did a back-correlation of the m/z of the proteins detected by MALDI-MSI to those identified by label-free quantitation. This allowed us to compare the label-free quantitation of proteins obtained in LC-MS/MS with the peak intensities observed in MALDI-MSI. We managed to link identification to nine peaks observed by MALDI-MSI. The results showed that the MSI~LC-MS/MS-LF workflow (i) allowed us to study a representative muscle proteome compared to a classical bottom-up workflow; and (ii) was sparsely impacted by matrix deposition and laser ablation. This workflow, performed as a proof-of-concept, suggests that a single tissue section can be used to perform MALDI-MSI and protein extraction, identification, and relative quantitation. PMID:28248242

  17. LC-MS Data Processing with MAVEN: A Metabolomic Analysis and Visualization Engine

    PubMed Central

    Clasquin, Michelle F.; Melamud, Eugene; Rabinowitz, Joshua D.

    2014-01-01

    MAVEN is an open-source software program for interactive processing of LC-MS-based metabolomics data. MAVEN enables rapid and reliable metabolite quantitation from multiple reaction monitoring data or high-resolution full-scan mass spectrometry data. It automatically detects and reports peak intensities for isotope-labeled metabolites. Menu-driven, click-based navigation allows visualization of raw and analyzed data. Here we provide a User Guide for MAVEN. Step-by-step instructions are provided for data import, peak alignment across samples, identification of metabolites that differ strongly between biological conditions, quantitation and visualization of isotope-labeling patterns, and export of tables of metabolite-specific peak intensities. Together, these instructions describe a workflow that allows efficient processing of raw LC-MS data into a form ready for biological analysis. PMID:22389014

  18. Unraveling Molecular Differences of Gastric Cancer by Label-Free Quantitative Proteomics Analysis.

    PubMed

    Dai, Peng; Wang, Qin; Wang, Weihua; Jing, Ruirui; Wang, Wei; Wang, Fengqin; Azadzoi, Kazem M; Yang, Jing-Hua; Yan, Zhen

    2016-01-21

    Gastric cancer (GC) has significant morbidity and mortality worldwide and especially in China. Its molecular pathogenesis has not been thoroughly elaborated. The acknowledged biomarkers for diagnosis, prognosis, recurrence monitoring and treatment are lacking. Proteins from matched pairs of human GC and adjacent tissues were analyzed by a coupled label-free Mass Spectrometry (MS) approach, followed by functional annotation with software analysis. Nano-LC-MS/MS, quantitative real-time polymerase chain reaction (qRT-PCR), western blot and immunohistochemistry were used to validate dysregulated proteins. One hundred forty-six dysregulated proteins with more than twofold expressions were quantified, 22 of which were first reported to be relevant with GC. Most of them were involved in cancers and gastrointestinal disease. The expression of a panel of four upregulated nucleic acid binding proteins, heterogeneous nuclear ribonucleoprotein hnRNPA2B1, hnRNPD, hnRNPL and Y-box binding protein 1 (YBX-1) were validated by Nano-LC-MS/MS, qRT-PCR, western blot and immunohistochemistry assays in ten GC patients' tissues. They were located in the keynotes of a predicted interaction network and might play important roles in abnormal cell growth. The label-free quantitative proteomic approach provides a deeper understanding and novel insight into GC-related molecular changes and possible mechanisms. It also provides some potential biomarkers for clinical diagnosis.

  19. Data processing has major impact on the outcome of quantitative label-free LC-MS analysis.

    PubMed

    Chawade, Aakash; Sandin, Marianne; Teleman, Johan; Malmström, Johan; Levander, Fredrik

    2015-02-06

    High-throughput multiplexed protein quantification using mass spectrometry is steadily increasing in popularity, with the two major techniques being data-dependent acquisition (DDA) and targeted acquisition using selected reaction monitoring (SRM). However, both techniques involve extensive data processing, which can be performed by a multitude of different software solutions. Analysis of quantitative LC-MS/MS data is mainly performed in three major steps: processing of raw data, normalization, and statistical analysis. To evaluate the impact of data processing steps, we developed two new benchmark data sets, one each for DDA and SRM, with samples consisting of a long-range dilution series of synthetic peptides spiked in a total cell protein digest. The generated data were processed by eight different software workflows and three postprocessing steps. The results show that the choice of the raw data processing software and the postprocessing steps play an important role in the final outcome. Also, the linear dynamic range of the DDA data could be extended by an order of magnitude through feature alignment and a charge state merging algorithm proposed here. Furthermore, the benchmark data sets are made publicly available for further benchmarking and software developments.

  20. LC-MS/MS analysis of permethylated free oligosaccharides and N-glycans derived from human, bovine, and goat milk samples.

    PubMed

    Dong, Xue; Zhou, Shiyue; Mechref, Yehia

    2016-06-01

    Oligosaccharides in milk not only provide nutrition to the infants but also have significant immune biofunctions such as inhibition of pathogen binding to the host cell. The main component in milk oligosaccharides is free oligosaccharides. Since the proteins in milk are highly glycosylated, N-glycans in milk also play an import role. In this study, we investigated the permethylated free oligosaccharides and N-glycans extracted from bovine, goat, and human milks using LC-MS/MS. Quantitation profiles of free oligosaccharides and N-glycans were reported. The number of free oligosaccharides observed in bovine, goat, and human milk samples (without isomeric consideration) were 11, 8, and 11, respectively. Human milk had more complex free oligosaccharides structures than the other two milk samples. Totally 58, 21, and 43 N-glycan structures (without isomeric consideration) were associated with whey proteins extracted from bovine, goat, and human milk samples, respectively. Bovine milk free oligosaccharides and N-glycans from whey proteins were highly sialylated and to a lesser extend fucosylated. Goat and human milk free oligosaccharides and N-glycans from whey proteins were both highly fucosylated. Also, the isomeric glycans in milk samples were determined by porous graphitic carbon LC at elevated temperatures. For example, separation of human milk free oligosaccharide Gal-GlcNAc-(Fuc)-Gal-Glc and Gal-GlcNAc-Gal-Glc-Fuc isomers was achieved using porous graphitic carbon column. Permethylation of the glycan structures facilitated the interpretation of MS/MS. For example, internal cleavage and glycosidic bond cleavage are readily distinguished in the tandem mass spectra of permethylated glycans. This feature resulted in the identification of several isomers. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. A survey of free glutamic acid in foods using a robust LC-MS/MS method.

    PubMed

    Cebi, Nur; Dogan, Canan Ekinci; Olgun, Elmas Oktem; Sagdic, Osman

    2018-05-15

    An effective and simultaneous liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was used with the aim of quantifying monosodium glutamate (MSG) in foodstuffs, such as chips, taste cubes, sauces and soups. The results were linear (R 2  = 1), with very low LOD and LOQ values, 1.0 µg/kg, 5.0 µg/kg, respectively. Excellent repeatability and reproducibility were also achieved. This highly sensitive and robust LC-MS/MS technique was applied successfully for the detection and quantification of MSG in a wide variety of foodstuffs. MSG contents ranged from 0.01 g/100 g to 15.39 g/100 g in food samples. Importantly, determination of free glutamic acid in the daily diet could also prevent various side effects associated with consumption of excess free glutamic acid. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Simultaneous LC/MS/MS determination of thiols and disulfides in urine samples based on differential labeling with ferrocene-based maleimides.

    PubMed

    Seiwert, Bettina; Karst, Uwe

    2007-09-15

    A method for the simultaneous determination of a series of thiols and disulfides in urine samples has been developed based on the sequential labeling of free and bound thiol functionalities with two ferrocene-based maleimide reagents. The sample is first exposed to N-(2-ferroceneethyl)maleimide, thus leading to the derivatization of free thiol groups in the sample. After quantitative reaction and subsequent reduction of the disulfide-bound thiols by tris(2-carboxyethyl)phosphine, the newly formed thiol functionalities are reacted with ferrocenecarboxylic acid-(2-maleimidoyl)ethylamide. The reaction products are determined by LC/MS/MS in the multiple reaction mode, and precursor ion scan as well as neutral loss scan is applied to detect unknown further thiols. The method was successfully applied to the analysis of free and disulfide-bound thiols in urine samples. Limits of detection are 30 to 110 nM, and the linear range comprises two decades of concentration, thus covering the relevant concentration range of thiols in urine samples. The thiol and disulfide concentrations were referred to the creatinine content to compensate for different sample volumes. As some calibration standards for the disulfides are not commercially available, they were synthesized in an electrochemical flow-through cell. This allowed the synthesis of hetero- and homodimeric disulfides.

  3. A rapid and sensitive method for the simultaneous analysis of aliphatic and polar molecules containing free carboxyl groups in plant extracts by LC-MS/MS

    PubMed Central

    2009-01-01

    Background Aliphatic molecules containing free carboxyl groups are important intermediates in many metabolic and signalling reactions, however, they accumulate to low levels in tissues and are not efficiently ionized by electrospray ionization (ESI) compared to more polar substances. Quantification of aliphatic molecules becomes therefore difficult when small amounts of tissue are available for analysis. Traditional methods for analysis of these molecules require purification or enrichment steps, which are onerous when multiple samples need to be analyzed. In contrast to aliphatic molecules, more polar substances containing free carboxyl groups such as some phytohormones are efficiently ionized by ESI and suitable for analysis by LC-MS/MS. Thus, the development of a method with which aliphatic and polar molecules -which their unmodified forms differ dramatically in their efficiencies of ionization by ESI- can be simultaneously detected with similar sensitivities would substantially simplify the analysis of complex biological matrices. Results A simple, rapid, specific and sensitive method for the simultaneous detection and quantification of free aliphatic molecules (e.g., free fatty acids (FFA)) and small polar molecules (e.g., jasmonic acid (JA), salicylic acid (SA)) containing free carboxyl groups by direct derivatization of leaf extracts with Picolinyl reagent followed by LC-MS/MS analysis is presented. The presence of the N atom in the esterified pyridine moiety allowed the efficient ionization of 25 compounds tested irrespective of their chemical structure. The method was validated by comparing the results obtained after analysis of Nicotiana attenuata leaf material with previously described analytical methods. Conclusion The method presented was used to detect 16 compounds in leaf extracts of N. attenuata plants. Importantly, the method can be adapted based on the specific analytes of interest with the only consideration that the molecules must contain at

  4. Proteome analysis of excretory-secretory proteins of Entamoeba histolytica HM1:IMSS via LC-ESI-MS/MS and LC-MALDI-TOF/TOF.

    PubMed

    Ujang, Jorim Anak; Kwan, Soon Hong; Ismail, Mohd Nazri; Lim, Boon Huat; Noordin, Rahmah; Othman, Nurulhasanah

    2016-01-01

    Excretory-secretory (ES) proteins of E. histolytica are thought to play important roles in the host invasion, metabolism, and defence. Elucidation of the types and functions of E. histolytica ES proteins can further our understanding of the disease pathogenesis. Thus, the aim of this study is to use proteomics approach to better understand the complex ES proteins of the protozoa. E. histolytica ES proteins were prepared by culturing the trophozoites in protein-free medium. The ES proteins were identified using two mass spectrometry tools, namely, LC-ESI-MS/MS and LC-MALDI-TOF/TOF. The identified proteins were then classified according to their biological processes, molecular functions, and cellular components using the Panther classification system (PantherDB). A complementary list of 219 proteins was identified; this comprised 201 proteins detected by LC-ESI-MS/MS and 107 proteins by LC-MALDI-TOF/TOF. Of the 219 proteins, 89 were identified by both mass-spectrometry systems, while 112 and 18 proteins were detected exclusively by LC-ESI-MS/MS and LC-MALDI-TOF/TOF respectively. Biological protein functional analysis using PantherDB showed that 27% of the proteins were involved in metabolic processes. Using molecular functional and cellular component analyses, 35% of the proteins were found to be involved in catalytic activity, and 21% were associated with the cell parts. This study showed that complementary use of LC-ESI-MS/MS and LC-MALDI-TOF/TOF has improved the identification of ES proteins. The results have increased our understanding of the types of proteins excreted/secreted by the amoeba and provided further evidence of the involvement of ES proteins in intestinal colonisation and evasion of the host immune system, as well as in encystation and excystation of the parasite.

  5. ICPD-a new peak detection algorithm for LC/MS.

    PubMed

    Zhang, Jianqiu; Haskins, William

    2010-12-01

    The identification and quantification of proteins using label-free Liquid Chromatography/Mass Spectrometry (LC/MS) play crucial roles in biological and biomedical research. Increasing evidence has shown that biomarkers are often low abundance proteins. However, LC/MS systems are subject to considerable noise and sample variability, whose statistical characteristics are still elusive, making computational identification of low abundance proteins extremely challenging. As a result, the inability of identifying low abundance proteins in a proteomic study is the main bottleneck in protein biomarker discovery. In this paper, we propose a new peak detection method called Information Combining Peak Detection (ICPD ) for high resolution LC/MS. In LC/MS, peptides elute during a certain time period and as a result, peptide isotope patterns are registered in multiple MS scans. The key feature of the new algorithm is that the observed isotope patterns registered in multiple scans are combined together for estimating the likelihood of the peptide existence. An isotope pattern matching score based on the likelihood probability is provided and utilized for peak detection. The performance of the new algorithm is evaluated based on protein standards with 48 known proteins. The evaluation shows better peak detection accuracy for low abundance proteins than other LC/MS peak detection methods.

  6. ICPD-A New Peak Detection Algorithm for LC/MS

    PubMed Central

    2010-01-01

    Background The identification and quantification of proteins using label-free Liquid Chromatography/Mass Spectrometry (LC/MS) play crucial roles in biological and biomedical research. Increasing evidence has shown that biomarkers are often low abundance proteins. However, LC/MS systems are subject to considerable noise and sample variability, whose statistical characteristics are still elusive, making computational identification of low abundance proteins extremely challenging. As a result, the inability of identifying low abundance proteins in a proteomic study is the main bottleneck in protein biomarker discovery. Results In this paper, we propose a new peak detection method called Information Combining Peak Detection (ICPD ) for high resolution LC/MS. In LC/MS, peptides elute during a certain time period and as a result, peptide isotope patterns are registered in multiple MS scans. The key feature of the new algorithm is that the observed isotope patterns registered in multiple scans are combined together for estimating the likelihood of the peptide existence. An isotope pattern matching score based on the likelihood probability is provided and utilized for peak detection. Conclusions The performance of the new algorithm is evaluated based on protein standards with 48 known proteins. The evaluation shows better peak detection accuracy for low abundance proteins than other LC/MS peak detection methods. PMID:21143790

  7. Towards a proteome signature for invasive ductal breast carcinoma derived from label-free nanoscale LC-MS protein expression profiling of tumorous and glandular tissue.

    PubMed

    Röwer, Claudia; Vissers, Johannes P C; Koy, Cornelia; Kipping, Marc; Hecker, Michael; Reimer, Toralf; Gerber, Bernd; Thiesen, Hans-Jürgen; Glocker, Michael O

    2009-12-01

    As more and more alternative treatments become available for breast carcinoma, there is a need to stratify patients and individual molecular information seems to be suitable for this purpose. In this study, we applied label-free protein quantitation by nanoscale LC-MS and investigated whether this approach could be used for defining a proteome signature for invasive ductal breast carcinoma. Tissue samples from healthy breast and tumor were collected from three patients. Protein identifications were based on LC-MS peptide fragmentation data which were obtained simultaneously to the quantitative information. Hereby, an invasive ductal breast carcinoma proteome signature was generated which contains 60 protein entries. The on-column concentrations for osteoinductive factor, vimentin, GAP-DH, and NDKA are provided as examples. These proteins represent distinctive gene ontology groups of differentially expressed proteins and are discussed as risk markers for primary tumor pathogenesis. The developed methodology has been found well applicable in a clinical environment in which standard operating procedures can be kept; a prerequisite for the definition of molecular parameter sets that shall be capable for stratification of patients.

  8. Rugged LC-MS/MS survey analysis for acrylamide in foods.

    PubMed

    Roach, John A G; Andrzejewski, Denis; Gay, Martha L; Nortrup, David; Musser, Steven M

    2003-12-17

    The described liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the detection of acrylamide in food entails aqueous room temperature extraction, SPE cleanup, and analysis by LC-MS/MS. The method is applicable to a wide variety of foods. [(13)C(3)]acrylamide is the internal standard. The limit of quantitation is 10 ppb (microg/kg). Data were obtained in duplicate from >450 products representing >35 different food types. The variability in analyte levels in certain food types suggests that it may be possible to reduce acrylamide levels in those foods.

  9. Heterosis-associated proteome analyses of maize (Zea mays L.) seminal roots by quantitative label-free LC-MS.

    PubMed

    Marcon, Caroline; Lamkemeyer, Tobias; Malik, Waqas Ahmed; Ungrue, Denise; Piepho, Hans-Peter; Hochholdinger, Frank

    2013-11-20

    Heterosis is the superior performance of heterozygous F1-hybrid plants compared to their homozygous genetically distinct parents. Seminal roots are embryonic roots that play an important role during early maize (Zea mays L.) seedling development. In the present study the most abundant soluble proteins of 2-4cm seminal roots of the reciprocal maize F1-hybrids B73×Mo17 and Mo17×B73 and their parental inbred lines B73 and Mo17 were quantified by label-free LC-MS/MS. In total, 1918 proteins were detected by this shot-gun approach. Among those, 970 were represented by at least two peptides and were further analyzed. Eighty-five proteins displayed non-additive accumulation in at least one hybrid. The functional category protein metabolism was the most abundant class of non-additive proteins represented by 27 proteins. Within this category 16 of 17 non-additively accumulated ribosomal proteins showed high or above high parent expression in seminal roots. These results imply that an increased protein synthesis rate in hybrids might be related to the early manifestation of hybrid vigor in seminal roots. In the present study a shot-gun proteomics approach allowed for the identification of 1917 proteins and analysis of 970 seminal root proteins of maize that were represented by at least 2 peptides. The comparison of proteome complexity of reciprocal hybrids and their parental inbred lines indicates an increased protein synthesis rate in hybrids that may contribute to the early manifestation of heterosis in seminal roots. This article is part of a Special Issue entitled: Translational Plant Proteomics. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Effects of sample injection amount and time-of-flight mass spectrometric detection dynamic range on metabolome analysis by high-performance chemical isotope labeling LC-MS.

    PubMed

    Zhou, Ruokun; Li, Liang

    2015-04-06

    The effect of sample injection amount on metabolome analysis in a chemical isotope labeling (CIL) liquid chromatography-mass spectrometry (LC-MS) platform was investigated. The performance of time-of-flight (TOF) mass spectrometers with and without a high-dynamic-range (HD) detection system was compared in the analysis of (12)C2/(13)C2-dansyl labeled human urine samples. An average of 1635 ± 21 (n = 3) peak pairs or putative metabolites was detected using the HD-TOF-MS, compared to 1429 ± 37 peak pairs from a conventional or non-HD TOF-MS. In both instruments, signal saturation was observed. However, in the HD-TOF-MS, signal saturation was mainly caused by the ionization process, while in the non-HD TOF-MS, it was caused by the detection process. To extend the MS detection range in the non-HD TOF-MS, an automated switching from using (12)C to (13)C-natural abundance peaks for peak ratio calculation when the (12)C peaks are saturated has been implemented in IsoMS, a software tool for processing CIL LC-MS data. This work illustrates that injecting an optimal sample amount is important to maximize the metabolome coverage while avoiding the sample carryover problem often associated with over-injection. A TOF mass spectrometer with an enhanced detection dynamic range can also significantly increase the number of peak pairs detected. In chemical isotope labeling (CIL) LC-MS, relative metabolite quantification is done by measuring the peak ratio of a (13)C2-/(12)C2-labeled peak pair for a given metabolite present in two comparative samples. The dynamic range of peak ratio measurement does not need to be very large, as only subtle changes of metabolite concentrations are encountered in most metabolomic studies where relative metabolome quantification of different groups of samples is performed. However, the absolute concentrations of different metabolites can be very different, requiring a technique to provide a wide detection dynamic range to allow the detection of as

  11. Reliable LC-MS quantitative glycomics using iGlycoMab stable isotope labeled glycans as internal standards.

    PubMed

    Zhou, Shiyue; Tello, Nadia; Harvey, Alex; Boyes, Barry; Orlando, Ron; Mechref, Yehia

    2016-06-01

    Glycans have numerous functions in various biological processes and participate in the progress of diseases. Reliable quantitative glycomic profiling techniques could contribute to the understanding of the biological functions of glycans, and lead to the discovery of potential glycan biomarkers for diseases. Although LC-MS is a powerful analytical tool for quantitative glycomics, the variation of ionization efficiency and MS intensity bias are influencing quantitation reliability. Internal standards can be utilized for glycomic quantitation by MS-based methods to reduce variability. In this study, we used stable isotope labeled IgG2b monoclonal antibody, iGlycoMab, as an internal standard to reduce potential for errors and to reduce variabililty due to sample digestion, derivatization, and fluctuation of nanoESI efficiency in the LC-MS analysis of permethylated N-glycans released from model glycoproteins, human blood serum, and breast cancer cell line. We observed an unanticipated degradation of isotope labeled glycans, tracked a source of such degradation, and optimized a sample preparation protocol to minimize degradation of the internal standard glycans. All results indicated the effectiveness of using iGlycoMab to minimize errors originating from sample handling and instruments. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. LC-MS/MS Analysis of Permethylated Free Oligosaccharides and N-glycans Derived from Human, Bovine, and Goat Milk Samples

    PubMed Central

    Dong, Xue; Zhou, Shiyue; Mechref, Yehia

    2016-01-01

    Oligosaccharides in milk not only provide nutrition to the infants, but also have significant immune biofunctions such as inhibition of pathogen binding to the host cell. The main component in milk oligosaccharides is free oligosaccharides. Since the proteins in milk are highly glycosylated, N-glycans in milk also play an import role. In this study, we investigated the permethylated free oligosaccharides and N-glycans extracted from bovine, goat and human milk using LC-MS/MS. Quantitation profiles of free oligosaccharides and N-glycans were reported. The number of free oligosaccharides observed in bovine, goat and human milk samples (without isomeric consideration) were 11, 8 and 11 respectively. Human milk had more complex free oligosaccharides structures than the other two milk samples. Totally 58, 21, and 43 N-glycan structures (without isomeric consideration) were associated with whey proteins extracted from bovine, goat and human milk samples, respectively. Bovine milk free oligosaccharides and N-glycans from whey proteins were highly sialylated and to a lesser extend fucosylated. Goat and human milk free oligosaccharides and N-glycans from whey proteins were both highly fucosylated. Also, the isomeric glycans in milk samples were determined by PGC LC at elevated temperatures. For example, separation of human milk free oligosaccharide Gal-GlcNAc-(Fuc)-Gal-Glc and Gal-GlcNAc-Gal-Glc-Fuc isomers was achieved using PGC column. Permethylation of the glycan structures facilitated the interpretation of tandem MS. For example, internal cleavage and glycosidic bond cleavage are readily distinguished in the tandem mass spectra of permethylated glycans. This feature resulted in the identification of several isomers. PMID:26959529

  13. Chemical Isotope Labeling LC-MS for High Coverage and Quantitative Profiling of the Hydroxyl Submetabolome in Metabolomics.

    PubMed

    Zhao, Shuang; Luo, Xian; Li, Liang

    2016-11-01

    A key step in metabolomics is to perform accurate relative quantification of the metabolomes in comparative samples with high coverage. Hydroxyl-containing metabolites are an important class of the metabolome with diverse structures and physical/chemical properties; however, many of them are difficult to detect with high sensitivity. We present a high-performance chemical isotope labeling liquid chromatography mass spectrometry (LC-MS) technique for in-depth profiling of the hydroxyl submetabolome, which involves the use of acidic liquid-liquid extraction to enrich hydroxyl metabolites into ethyl acetate from an aqueous sample. After drying and then redissolving in acetonitrile, the metabolite extract is labeled using a base-activated 12 C- or 13 C-dansylation reaction. A fast step-gradient LC-UV method is used to determine the total concentration of labeled metabolites. On the basis of the concentration information, a 12 C-labeled individual sample is mixed with an equal mole amount of a 13 C-labeled pool or control for relative metabolite quantification. The 12 C-/ 13 C-labeled mixtures are individually analyzed by LC-MS, and the resultant peak pairs of labeled metabolites in MS are measured for relative quantification and metabolite identification. A standard library of 85 hydroxyl compounds containing MS, retention time, and MS/MS information was constructed for positive metabolite identification based on matches of two or all three of these parameters with those of an unknown. Using human urine as an example, we analyzed samples of 1:1 12 C-/ 13 C-labeled urine in triplicate with triplicate runs per sample and detected an average of 3759 ± 45 peak pairs or metabolites per run and 3538 ± 71 pairs per sample with 3093 pairs in common (n = 9). Out of the 3093 peak pairs, 2304 pairs (75%) could be positively or putatively identified based on metabolome database searches, including 20 pairs positively identified using the dansylated hydroxyl standards library

  14. Methods for the analysis of organophosphorus flame retardants-Comparison of GC-EI-MS, GC-NCI-MS, LC-ESI-MS/MS, and LC-APCI-MS/MS.

    PubMed

    Tokumura, Masahiro; Miyake, Yuichi; Wang, Qi; Nakayama, Hayato; Amagai, Takashi; Ogo, Sayaka; Kume, Kazunari; Kobayashi, Takeshi; Takasu, Shinji; Ogawa, Kumiko

    2018-04-16

    Organophosphorus flame retardants (PFRs) are extensively used as alternatives to banned polybrominated diphenyl ethers (PBDEs) and hexabromocyclododecane (HBCD). In this study, we analyzed 14 PFRs by means of four mass-spectrometry-based methods: gas chromatography combined with electron-impact mass spectrometry (GC-EI-MS) or negative-chemical-ionization mass spectrometry (GC-NCI-MS) and liquid chromatography combined with tandem mass spectrometry using electrospray ionization (LC-ESI-MS/MS) or atmospheric pressure chemical ionization (LC-APCI-MS/MS). The limits of quantification (LOQs) for LC-ESI-MS/MS and LC-APCI-MS/MS (0.81-970 pg) were 1-2 orders of magnitude lower than the LOQs for GC-EI-MS and GC-NCI-MS (2.3-3900 pg). LC-APCI-MS/MS showed the lowest LOQs (mean = 41 pg; median = 3.4 pg) for all but two of the PFRs targeted in this study. For LC-APCI-MS/MS, the lowest LOQ was observed for tributyl phosphate (TBP) (0.81 pg), and the highest was observed for tris(butoxyethyl) phosphate (TBOEP) (36 pg). The results of this study indicate that LC-APCI-MS/MS is the optimum analytical method for the target PFRs, at least in terms of LOQ.

  15. The EIPeptiDi tool: enhancing peptide discovery in ICAT-based LC MS/MS experiments.

    PubMed

    Cannataro, Mario; Cuda, Giovanni; Gaspari, Marco; Greco, Sergio; Tradigo, Giuseppe; Veltri, Pierangelo

    2007-07-15

    Isotope-coded affinity tags (ICAT) is a method for quantitative proteomics based on differential isotopic labeling, sample digestion and mass spectrometry (MS). The method allows the identification and relative quantification of proteins present in two samples and consists of the following phases. First, cysteine residues are either labeled using the ICAT Light or ICAT Heavy reagent (having identical chemical properties but different masses). Then, after whole sample digestion, the labeled peptides are captured selectively using the biotin tag contained in both ICAT reagents. Finally, the simplified peptide mixture is analyzed by nanoscale liquid chromatography-tandem mass spectrometry (LC-MS/MS). Nevertheless, the ICAT LC-MS/MS method still suffers from insufficient sample-to-sample reproducibility on peptide identification. In particular, the number and the type of peptides identified in different experiments can vary considerably and, thus, the statistical (comparative) analysis of sample sets is very challenging. Low information overlap at the peptide and, consequently, at the protein level, is very detrimental in situations where the number of samples to be analyzed is high. We designed a method for improving the data processing and peptide identification in sample sets subjected to ICAT labeling and LC-MS/MS analysis, based on cross validating MS/MS results. Such a method has been implemented in a tool, called EIPeptiDi, which boosts the ICAT data analysis software improving peptide identification throughout the input data set. Heavy/Light (H/L) pairs quantified but not identified by the MS/MS routine, are assigned to peptide sequences identified in other samples, by using similarity criteria based on chromatographic retention time and Heavy/Light mass attributes. EIPeptiDi significantly improves the number of identified peptides per sample, proving that the proposed method has a considerable impact on the protein identification process and, consequently, on

  16. Microdose study of a P-glycoprotein substrate, fexofenadine, using a non-radioisotope-labelled drug and LC/MS/MS.

    PubMed

    Yamazaki, A; Kumagai, Y; Yamane, N; Tozuka, Z; Sugiyama, Y; Fujita, T; Yokota, S; Maeda, M

    2010-04-01

    Fexofenadine is a P-glycoprotein substrate of low bioavailability. It is primarily excreted into faeces as a parent drug via biliary excretion. The predictability from microdose data for the drug absorbed via transporters such as P-glycoprotein is not known. Therefore, this study assessed the predictability of therapeutic-dose pharmacokinetics of fexofenadine from microdosing data using non-radioisotope-labelled drug and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS). In a single dose, randomized, two-way crossover study, eight subjects received a microdose (100 microg) or a therapeutic dose (60 mg) of fexofenadine. Blood samples were collected until 12 h after dosing, and assayed using LC/MS/MS. Plasma concentration-time curves of fexofenadine between microdose and therapeutic dose were similar. The mean +/- SD of C(max) normalized to 60 mg dose after microdose and therapeutic dose were 379 +/- 147 and 275 +/- 145 ng/mL respectively. The mean AUC(last) normalized to 60 mg dose after microdose and therapeutic dose were 1914 +/- 738 and 1431 +/- 432 ng/h/mL respectively. The mean dose-adjusted C(max) and AUC(last) after microdose were higher compared with those after therapeutic dose. Individual plots of C(max) and AUC(last) normalized to 60 mg dose, were similar for microdose and therapeutic dose. None of the pharmacokinetic parameters were statistically different using anova. Overall, the microdose pharmacokinetics profile was similar to, and hence predictive of, that of the therapeutic dose. For the P-glycoprotein substrate fexofenadine, the predictability of therapeutic-dose pharmacokinetics from microdose data was good. A microdose study using a non-radioisotope-labelled drug and LC/MS/MS is convenient, and has the potential to aid the early selection of drug candidates.

  17. LC-MS and MS/MS in the analysis of recombinant proteins

    NASA Astrophysics Data System (ADS)

    Coulot, M.; Domon, B.; Grossenbacher, H.; Guenat, C.; Maerki, W.; Müller, D. R.; Richter, W. J.

    1993-03-01

    Applicability and performance of electrospray ionization mass spectrometry (ESIMS) is demonstrated for protein analysis. ESIMS is applied in conjunction with on-line HPLC (LC-ESlMS) and direct tandem mass spectrometry (positive and negative ion mode ESlMS/MS) to the structural characterization of a recombinant protein (r-hirudin variant 1) and a congener phosphorylated at threonine 45 (RP-1).

  18. freeQuant: A Mass Spectrometry Label-Free Quantification Software Tool for Complex Proteome Analysis.

    PubMed

    Deng, Ning; Li, Zhenye; Pan, Chao; Duan, Huilong

    2015-01-01

    Study of complex proteome brings forward higher request for the quantification method using mass spectrometry technology. In this paper, we present a mass spectrometry label-free quantification tool for complex proteomes, called freeQuant, which integrated quantification with functional analysis effectively. freeQuant consists of two well-integrated modules: label-free quantification and functional analysis with biomedical knowledge. freeQuant supports label-free quantitative analysis which makes full use of tandem mass spectrometry (MS/MS) spectral count, protein sequence length, shared peptides, and ion intensity. It adopts spectral count for quantitative analysis and builds a new method for shared peptides to accurately evaluate abundance of isoforms. For proteins with low abundance, MS/MS total ion count coupled with spectral count is included to ensure accurate protein quantification. Furthermore, freeQuant supports the large-scale functional annotations for complex proteomes. Mitochondrial proteomes from the mouse heart, the mouse liver, and the human heart were used to evaluate the usability and performance of freeQuant. The evaluation showed that the quantitative algorithms implemented in freeQuant can improve accuracy of quantification with better dynamic range.

  19. Enhanced sensitivity and multiplexing with 2D LC/MRM-MS and labeled standards for deeper and more comprehensive protein quantitation.

    PubMed

    Percy, Andrew J; Simon, Romain; Chambers, Andrew G; Borchers, Christoph H

    2014-06-25

    Mass spectrometry (MS)-based protein quantitation is increasingly being employed to verify candidate protein biomarkers. Multiple or selected reaction monitoring-mass spectrometry (MRM-MS or SRM-MS) with isotopically labeled internal standards has proven to be a successful approach in that regard, but has yet to reach its full potential in terms of multiplexing and sensitivity. Here, we report the development of a new MRM method for the quantitation of 253 disease-associated proteins (represented by 625 interference-free peptides) in 13 LC fractions. This 2D RPLC/MRM-MS approach extends the depth and breadth of the assay by 2 orders of magnitude over pre-fractionation-free assays, with 31 proteins below 10 ng/mL and 41 proteins above 10 ng/mL now quantifiable. Standard flow rates are used in both chromatographic dimensions, and up-front depletion or antibody-based enrichment is not required. The LC separations utilize high and low pH conditions, with the former employing an ammonium hydroxide-based eluent, instead of the conventional ammonium formate, resulting in improved LC column lifetime and performance. The high sensitivity (determined concentration range: 15 mg/mL to 452 pg/mL) and robustness afforded by this method makes the full MRM panel, or subsets thereof, useful for the verification of disease-associated plasma protein biomarkers in patient samples. The described research extends the breadth and depth of protein quantitation in undepleted and non-enriched human plasma by employing standard-flow 2D RPLC/MRM-MS in conjunction with a complex mixture of isotopically labeled peptide standards. The proteins quantified are mainly putative biomarkers of non-communicable (i.e., non-infectious) disease (e.g., cardiovascular or cancer), which require pre-clinical verification and validation before clinical implementation. Based on the enhanced sensitivity and multiplexing, this quantitative plasma proteomic method should prove useful in future candidate biomarker

  20. Label-free LC-MS analysis of HER2+ breast cancer cell line response to HER2 inhibitor treatment.

    PubMed

    Di Luca, Alessio; Henry, Michael; Meleady, Paula; O'Connor, Robert

    2015-08-04

    Human epidermal growth-factor receptor (HER)-2 is overexpressed in 25 % of breast-cancers and is associated with an aggressive form of the disease with significantly shortened disease free and overall survival. In recent years, the use of HER2-targeted therapies, monoclonal-antibodies and small molecule tyrosine-kinase inhibitors has significantly improved the clinical outcome for HER2-positive breast-cancer patients. However, only a fraction of HER2-amplified patients will respond to therapy and the use of these treatments is often limited by tumour drug insensitivity or resistance and drug toxicities. Currently there is no way to identify likely responders or rational combinations with the potential to improve HER2-focussed treatment outcome. In order to further understand the molecular mechanisms of treatment-response with HER2-inhibitors, we used a highly-optimised and reproducible quantitative label-free LC-MS strategy to characterize the proteomes of HER2-overexpressing breast-cancer cell-lines (SKBR3, BT474 and HCC1954) in response to drug-treatment with HER2-inhibitors (lapatinib, neratinib or afatinib). Following 12 ours treatment with different HER2-inhibitors in the BT474 cell-line; compared to the untreated cells, 16 proteins changed significantly in abundance following lapatinib treatment (1 μM), 21 proteins changed significantly following neratinib treatment (150 nM) and 38 proteins changed significantly following afatinib treatment (150 nM). Whereas following 24 hours treatment with neratinib (200 nM) 46 proteins changed significantly in abundance in the HCC1954 cell-line and 23 proteins in the SKBR3 cell-line compared to the untreated cells. Analysing the data we found that, proteins like trifunctional-enzyme subunit-alpha, mitochondrial; heterogeneous nuclear ribonucleoprotein-R and lamina-associated polypeptide 2, isoform alpha were up-regulated whereas heat shock cognate 71 kDa protein was down-regulated in 3 or more comparisons. This proteomic

  1. Quantitative measurement of betaine and free choline in plasma, cereals and cereal products by isotope dilution LC-MS/MS.

    PubMed

    Bruce, Stephen J; Guy, Philippe A; Rezzi, Serge; Ross, Alastair B

    2010-02-24

    Betaine and choline are important components of the one-carbon metabolism cycle, linked with the amino acid homocysteine and lipid metabolism. Analyses of broad ranges of foods point to cereal based foods being important sources of betaine and choline, however to date there has been no detailed analysis of these compounds in cereal flours or cereal products. An analytical method based on optimization of an existing extraction followed by LC-MS/MS analysis was used to analyze 47 plasma samples, 32 cereal flours and cereal fractions, and 51 cereal products. For the method validation LLOQ, recovery, inter- and intraday repeatability were all performed. Whole-grain wheat and rye flours, and products based on these were the best whole cereal sources of betaine (747-1508 microg/g) and to a lesser extent choline (76-159 microg/g), while the bran fraction contained the highest concentrations of betaine and free-choline (2350-2899 microg/g and 366-384 microg/g respectively). Refined wheat flour and products contained lower concentrations, while rice and maize contained only very low and no detectable amounts of betaine respectively (0-10 microg/g), and low amounts of free-choline (<31 microg/g). These results were mirrored in cereal products analyzed, with whole-grain wheat or rye-based cereal products having the highest concentrations of the two metabolites. Plasma concentrations for betaine and free-choline in a group of 47 subjects ranged from 15.2-66.3 and 9.8-18.5 micromol/L respectively, within the range of previous reports. This LC-MS/MS method can be used to rapidly and sensitively quantify betaine and free-choline in plasma and cereal products. Whole-grain cereal products and products containing cereal bran appear to be excellent dietary sources of betaine and free-choline.

  2. LC-MS/MS analysis of uncommon paracetamol metabolites derived through in vitro polymerization and nitration reactions in liquid nitrogen.

    PubMed

    Trettin, Arne; Jordan, Jens; Tsikas, Dimitrios

    2014-09-01

    Paracetamol (acetaminophen, APAP) is a commonly used analgesic drug. Known paracetamol metabolites include the glucuronide, sulfate and mercapturate. N-Acetyl-benzoquinonimine (NAPQI) is considered the toxic intermediate metabolite of paracetamol. In vitro and in vivo studies indicate that paracetamol is also metabolized to additional poorly characterized metabolites. For example, metabolomic studies in urine samples of APAP-treated mice revealed metabolites such as APAP-sulfate-APAP and APAP-S-S-APAP in addition to the classical phase II metabolites. Here, we report on the development and application of LC-MS and LC-MS/MS approaches to study reactions of unlabelled and (2)H-labelled APAP with unlabelled and (15)N-labelled nitrite in aqueous phosphate buffers (pH 7.4) upon their immersion into liquid nitrogen (-196°C). In mechanistic studies, these reactions were also studied in aqueous buffer prepared in (18)O-labelled water. LC-MS and LC-MS/MS analyses were performed on a reverse-phase material (C18) using gradient elution (2mM ammonium acetate/acetonitrile), in positive and negative electrospray mode. We identified a series of APAP metabolites including di-, tri- and tetra-APAP, mono- and di-nitro-APAP and nitric ester of di-APAP. Our study indicates that nitrite induces oxidation, i.e., polymerization and nitration of APAP, when buffered APAP/nitrite solutions are immersed into liquid nitrogen. These reactions are specific for nitrite with respect to nitrate and do not proceed via intermediate formation of NAPQI. Potassium ions and physiological saline but not thiols inhibit nitrite- and shock-freeze-induced reactions of paracetamol. The underlying mechanism likely involves in situ formation of NO2 radicals from nitrite secondary to profound pH reduction (down to pH 1) and disproportionation. Polymeric paracetamol species can be analyzed as pentafluorobenzyl derivatives by LC-MS but not by GC-MS. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Techniques for quantitative LC-MS/MS analysis of protein therapeutics: advances in enzyme digestion and immunocapture.

    PubMed

    Fung, Eliza N; Bryan, Peter; Kozhich, Alexander

    2016-04-01

    LC-MS/MS has been investigated to quantify protein therapeutics in biological matrices. The protein therapeutics is digested by an enzyme to generate surrogate peptide(s) before LC-MS/MS analysis. One challenge is isolating protein therapeutics in the presence of large number of endogenous proteins in biological matrices. Immunocapture, in which a capture agent is used to preferentially bind the protein therapeutics over other proteins, is gaining traction. The protein therapeutics is eluted for digestion and LC-MS/MS analysis. One area of tremendous potential for immunocapture-LC-MS/MS is to obtain quantitative data where ligand-binding assay alone is not sufficient, for example, quantitation of antidrug antibody complexes. Herein, we present an overview of recent advance in enzyme digestion and immunocapture applicable to protein quantitation.

  4. LC-MS/MS signal suppression effects in the analysis of pesticides in complex environmental matrices.

    PubMed

    Choi, B K; Hercules, D M; Gusev, A I

    2001-02-01

    The application of LC separation and mobile phase additives in addressing LC-MS/MS matrix signal suppression effects for the analysis of pesticides in a complex environmental matrix was investigated. It was shown that signal suppression is most significant for analytes eluting early in the LC-MS analysis. Introduction of different buffers (e.g. ammonium formate, ammonium hydroxide, formic acid) into the LC mobile phase was effective in improving signal correlation between the matrix and standard samples. The signal improvement is dependent on buffer concentration as well as LC separation of the matrix components. The application of LC separation alone was not effective in addressing suppression effects when characterizing complex matrix samples. Overloading of the LC column by matrix components was found to significantly contribute to analyte-matrix co-elution and suppression of signal. This signal suppression effect can be efficiently compensated by 2D LC (LC-LC) separation techniques. The effectiveness of buffers and LC separation in improving signal correlation between standard and matrix samples is discussed.

  5. Single hair analysis of small molecules using MALDI-triple quadrupole MS imaging and LC-MS/MS: investigations on opportunities and pitfalls.

    PubMed

    Poetzsch, Michael; Steuer, Andrea E; Roemmelt, Andreas T; Baumgartner, Markus R; Kraemer, Thomas

    2014-12-02

    Single hair analysis normally requires extensive sample preparation microscale protocols including time-consuming steps like segmentation and extraction. Matrix assisted laser desorption and ionization mass spectrometric imaging (MALDI-MSI) was shown to be an alternative tool in single hair analysis, but still, questions remain. Therefore, an investigation of MALDI-MSI in single hair analysis concerning the extraction process, usage of internal standard (IS), and influences on the ionization processes were systematically investigated to enable the reliable application to hair analysis. Furthermore, single dose detection, quantitative correlation to a single hair, and hair strand LC-MS/MS results were performed, and the performance was compared to LC-MS/MS single hair monitoring. The MALDI process was shown to be independent from natural hair color and not influenced by the presence of melanin. Ionization was shown to be reproducible along and in between different hair samples. MALDI image intensities in single hair and hair snippets showed good semiquantitative correlation to zolpidem hair concentrations obtained from validated routine LC-MS/MS methods. MALDI-MSI is superior to LC-MS/MS analysis when a fast, easy, and cheap sample preparation is necessary, whereas LC-MS/MS showed higher sensitivity with the ability of single dose detection for zolpidem. MALDI-MSI and LC-MS/MS segmental single hair analysis showed good correlation, and both are suitable for consumption monitoring of drugs of abuse with a high time resolution.

  6. Glycidyl fatty acid esters in food by LC-MS/MS: method development.

    PubMed

    Becalski, A; Feng, S Y; Lau, B P-Y; Zhao, T

    2012-07-01

    An improved method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the analysis of glycidyl fatty acid esters in oils was developed. The method incorporates stable isotope dilution analysis (SIDA) for quantifying the five target analytes: glycidyl esters of palmitic (C16:0), stearic (C18:0), oleic (C18:1), linoleic (C18:2) and linolenic acid (C18:3). For the analysis, 10 mg sample of edible oil or fat is dissolved in acetone, spiked with deuterium labelled analogs of glycidyl esters and purified by a two-step chromatography on C18 and normal silica solid phase extraction (SPE) cartridges using methanol and 5% ethyl acetate in hexane, respectively. If the concentration of analytes is expected to be below 0.5 mg/kg, 0.5 g sample of oil is pre-concentrated first using a silica column. The dried final extract is re-dissolved in 250 μL of a mixture of methanol/isopropanol (1:1, v/v), 15 μL is injected on the analytical C18 LC column and analytes are eluted with 100% methanol. Detection of target glycidyl fatty acid esters is accomplished by LC-MS/MS using positive ion atmospheric pressure chemical ionization operating in Multiple Reaction Monitoring mode monitoring 2 ion transitions for each analyte. The method was tested on replicates of a virgin olive oil which was free of glycidyl esters. The method detection limit was calculated to be in the range of 70-150 μg/kg for each analyte using 10 mg sample and 1-3 μg/kg using 0.5 g sample of oil. Average recoveries of 5 glycidyl esters spiked at 10, 1 and 0.1 mg/kg were in the range 84% to 108%. The major advantage of our method is use of SIDA for all analytes using commercially available internal standards and detection limits that are lower by a factor of 5-10 from published methods when 0.5 g sample of oil is used. Additionally, MS/MS mass chromatograms offer greater specificity than liquid chromatography-mass spectrometry operated in selected ion monitoring mode. The method will be applied to

  7. In vivo D2O labeling to quantify static and dynamic changes in cholesterol and cholesterol esters by high resolution LC/MS[S

    PubMed Central

    Castro-Perez, Jose; Previs, Stephen F.; McLaren, David G.; Shah, Vinit; Herath, Kithsiri; Bhat, Gowri; Johns, Douglas G.; Wang, Sheng-Ping; Mitnaul, Lyndon; Jensen, Kristian; Vreeken, Robert; Hankemeier, Thomas; Roddy, Thomas P.; Hubbard, Brian K.

    2011-01-01

    High resolution LC/MS-MS and LC/APPI-MS methods have been established for the quantitation of flux in the turnover of cholesterol and cholesterol ester. Attention was directed toward quantifying the monoisotopic mass (M0) and that of the singly deuterated labeled (M+1) isotope. A good degree of isotopic dynamic range has been achieved by LC/MS-MS ranging from 3-4 orders of magnitude. Correlation between the linearity of GC/MS and LC atmospheric pressure photoionization (APPI)-MS are complimentary (r2 = 0.9409). To prove the viability of this particular approach, male C57Bl/6 mice on either a high carbohydrate (HC) or a high fat (HF) diet were treated with 2H2O for 96 h. Gene expression analysis showed an increase in the activity of stearoyl-CoA desaturase (Scd1) in the HC diet up to 69-fold (P < 0.0008) compared with the HF diet. This result was supported by the quantitative flux measurement of the isotopic incorporation of 2H into the respective cholesterol and cholesterol ester (CE) pools. We concluded that it is possible to readily obtain static and dynamic measurement of cholesterol and CEs in vivo by coupling novel LC/MS methods with stable isotope-based protocols. PMID:20884843

  8. Analysis of coffee for the presence of acrylamide by LC-MS/MS.

    PubMed

    Andrzejewski, Denis; Roach, John A G; Gay, Martha L; Musser, Steven M

    2004-04-07

    A variety of popular instant, ground, and brewed coffees were analyzed using a modified liquid chromatography-tandem mass spectrometry (LC-MS/MS) method specifically developed for the determination of acrylamide in foods. Coffee test portions were spiked with 13C3-labeled acrylamide as an internal standard prior to their extraction and cleanup. Ground coffees (1 g) and instant coffees (0.5 g) were extracted by shaking with 9 mL of water for 20 min. Brewed coffee test portions (9 mL) were taken through the cleanup procedure without further dilution with extraction solvent. Coffee test portions were cleaned up by passing 1.5 mL first through an Oasis HLB (hydrophilic/lipophilic copolymer sorbent) solid phase extraction (SPE) cartridge and then a Bond Elut-Accucat (cation and anion exchange sorbent) SPE cartridge. The cleaned up extracts were analyzed by positive ion electrospray LC-MS/MS. The MS/MS data was used to detect, confirm, and quantitate acrylamide. The limit of quantitation of the method was 10 ng/g for ground and instant coffees and 1.0 ng/mL for brewed coffee. The levels of acrylamide ranged from 45 to 374 ng/g in unbrewed coffee grounds, from 172 to 539 ng/g in instant coffee crystals, and from 6 to 16 ng/mL in brewed coffee.

  9. Assessment of salivary free cortisol levels by liquid chromatography with tandem mass spectrometry (LC-MS/MS) in patients treated with mitotane.

    PubMed

    Carrozza, Cinzia; Lapolla, Rosa; Gervasoni, Jacopo; Rota, Carlo Antonio; Locantore, Pietro; Pontecorvi, Alfredo; Zuppi, Cecilia; Persichilli, Silvia

    2012-01-01

    Mitotane is an adrenocytolytic agent used in adrenocortical carcinoma, inducing adrenal insufficiency, requiring replacement treatment. Such therapy is not easy to monitor because of mitotane interference. Salivary cortisol reflects a free fraction of plasma cortisol and may be useful in such patients. The aim of our study was to evaluate salivary cortisol by HPLC coupled to tandem-mass spectrometry (LC-MS/MS) and by an electrochemiluminescence immunoassay (ECLIA) in patients treated with mitotane. We enrolled 6 patients receiving mitotane and 2 Addison disease patients as negative controls and determined salivary cortisol rhythm. We also determined the salivary cortisol rhythm in 8 healthy subjects. Salivary samples (n=112) were assayed by ECLIA, using Roche Modular E170, and by LC-MS/MS. The mean values obtained by ECLIA were significantly higher than those obtained by LC-MS/MS in the mitotane group (p<0.001). In fact, in the group measured by LC-MS/MS, we observed several peaks eluting at a retention time different from the cortisol group, presumably due to cortisol-like analogues. In Addison disease, since steroidogenesis is absent, salivary cortisol values measured by the two methods did not show any significant difference (p=0.61). Salivary cortisol measured by LC-MS/MS is a selective method, excluding cortisol analogues accumulating in treated patients. Therefore, LC-MS/MS offers an effective system to monitor replacement therapy in mitotane treated patients.

  10. Lysozyme oxidation by singlet molecular oxygen: Peptide characterization using [18 O]-labeling oxygen and nLC-MS/MS.

    PubMed

    Marques, Emerson Finco; Medeiros, Marisa H G; Di Mascio, Paolo

    2017-11-01

    Singlet molecular oxygen ( 1 O 2 ) is generated in biological systems and reacts with different biomolecules. Proteins are a major target for 1 O 2 , and His, Tyr, Met, Cys, and Trp are oxidized at physiological pH. In the present study, the modification of lysozyme protein by 1 O 2 was investigated using mass spectrometry approaches. The experimental findings showed methionine, histidine, and tryptophan oxidation. The experiments were achieved using [ 18 O]-labeled 1 O 2 released from thermolabile endoperoxides in association with nano-scale liquid chromatography coupled to electrospray ionization mass spectrometry. The structural characterization by nLC-MS/MS of the amino acids in the tryptic peptides of the proteins showed addition of [ 18 O]-labeling atoms in different amino acids. Copyright © 2017 John Wiley & Sons, Ltd.

  11. Target analyte quantification by isotope dilution LC-MS/MS directly referring to internal standard concentrations--validation for serum cortisol measurement.

    PubMed

    Maier, Barbara; Vogeser, Michael

    2013-04-01

    Isotope dilution LC-MS/MS methods used in the clinical laboratory typically involve multi-point external calibration in each analytical series. Our aim was to test the hypothesis that determination of target analyte concentrations directly derived from the relation of the target analyte peak area to the peak area of a corresponding stable isotope labelled internal standard compound [direct isotope dilution analysis (DIDA)] may be not inferior to conventional external calibration with respect to accuracy and reproducibility. Quality control samples and human serum pools were analysed in a comparative validation protocol for cortisol as an exemplary analyte by LC-MS/MS. Accuracy and reproducibility were compared between quantification either involving a six-point external calibration function, or a result calculation merely based on peak area ratios of unlabelled and labelled analyte. Both quantification approaches resulted in similar accuracy and reproducibility. For specified analytes, reliable analyte quantification directly derived from the ratio of peak areas of labelled and unlabelled analyte without the need for a time consuming multi-point calibration series is possible. This DIDA approach is of considerable practical importance for the application of LC-MS/MS in the clinical laboratory where short turnaround times often have high priority.

  12. Analysis of anabolic steroids in human hair using LC-MS/MS.

    PubMed

    Deshmukh, Nawed; Hussain, Iltaf; Barker, James; Petroczi, Andrea; Naughton, Declan P

    2010-10-01

    New highly sensitive, specific, reliable, reproducible and robust LC-MS/MS methods were developed to detect the anabolic steroids, nandrolone and stanozolol, in human hair for the first time. Hair samples from 180 participants (108 males, 72 females, 62% athletes) were screened using ELISA which revealed 16 athletes as positive for stanozolol and 3 for nandrolone. Positive samples were confirmed on LC-MS/MS in selective reaction monitoring (SRM) mode. The assays for stanozolol and nandrolone showed good linearity in the range 1-400pg/mg and 5-400pg/mg, respectively. The methods were validated for LLOD, interday precision, intraday precision, specificity, extraction recovery and accuracy. The assays were capable of detecting 0.5pg stanozolol and 3.0pg nandrolone per mg of hair, when approximately 20mg of hair were processed. Analysis using LC-MS/MS confirmed 11 athletes' positive for stanozolol (5.0pg/mg to 86.3pg/mg) and 1 for nandrolone (14.0pg/mg) thus avoiding false results from ELISA screening. The results obtained demonstrate the application of these hair analysis methods to detect both steroids at low concentrations, hence reducing the amount of hair required significantly. The new methods complement urinalysis or blood testing and facilitate improved doping testing regimes. Hair analysis benefits from non-invasiveness, negligible risk of infection and facile sample storage and collection, whilst reducing risks of tampering and cross-contamination. Owing to the wide detection window, this approach may also offer an alternative approach for out-of-competition testing.

  13. LC-MS/MS Peptide Mapping with Automated Data Processing for Routine Profiling of N-Glycans in Immunoglobulins

    NASA Astrophysics Data System (ADS)

    Shah, Bhavana; Jiang, Xinzhao Grace; Chen, Louise; Zhang, Zhongqi

    2014-06-01

    Protein N-Glycan analysis is traditionally performed by high pH anion exchange chromatography (HPAEC), reversed phase liquid chromatography (RPLC), or hydrophilic interaction liquid chromatography (HILIC) on fluorescence-labeled glycans enzymatically released from the glycoprotein. These methods require time-consuming sample preparations and do not provide site-specific glycosylation information. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) peptide mapping is frequently used for protein structural characterization and, as a bonus, can potentially provide glycan profile on each individual glycosylation site. In this work, a recently developed glycopeptide fragmentation model was used for automated identification, based on their MS/MS, of N-glycopeptides from proteolytic digestion of monoclonal antibodies (mAbs). Experimental conditions were optimized to achieve accurate profiling of glycoforms. Glycan profiles obtained from LC-MS/MS peptide mapping were compared with those obtained from HPAEC, RPLC, and HILIC analyses of released glycans for several mAb molecules. Accuracy, reproducibility, and linearity of the LC-MS/MS peptide mapping method for glycan profiling were evaluated. The LC-MS/MS peptide mapping method with fully automated data analysis requires less sample preparation, provides site-specific information, and may serve as an alternative method for routine profiling of N-glycans on immunoglobulins as well as other glycoproteins with simple N-glycans.

  14. LC-MS based analysis of endogenous steroid hormones in human hair.

    PubMed

    Gao, Wei; Kirschbaum, Clemens; Grass, Juliane; Stalder, Tobias

    2016-09-01

    The quantification of endogenous steroid hormone concentrations in hair is increasingly used as a method for obtaining retrospective information on long-term integrated hormone exposure. Several different analytical procedures have been employed for hair steroid analysis, with liquid chromatography-mass spectrometry (LC-MS) being recognized as a particularly powerful analytical tool. Several methodological aspects affect the performance of LC-MS systems for hair steroid analysis, including sample preparation and pretreatment, steroid extraction, post-incubation purification, LC methodology, ionization techniques and MS specifications. Here, we critically review the differential value of such protocol variants for hair steroid hormones analysis, focusing on both analytical quality and practical feasibility issues. Our results show that, when methodological challenges are adequately addressed, LC-MS protocols can not only yield excellent sensitivity and specificity but are also characterized by relatively simple sample processing and short run times. This makes LC-MS based hair steroid protocols particularly suitable as a high-quality option for routine application in research contexts requiring the processing of larger numbers of samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Automated LC-HRMS(/MS) Approach for the Annotation of Fragment Ions Derived from Stable Isotope Labeling-Assisted Untargeted Metabolomics

    PubMed Central

    2014-01-01

    Structure elucidation of biological compounds is still a major bottleneck of untargeted LC-HRMS approaches in metabolomics research. The aim of the present study was to combine stable isotope labeling and tandem mass spectrometry for the automated interpretation of the elemental composition of fragment ions and thereby facilitate the structural characterization of metabolites. The software tool FragExtract was developed and evaluated with LC-HRMS/MS spectra of both native 12C- and uniformly 13C (U-13C)-labeled analytical standards of 10 fungal substances in pure solvent and spiked into fungal culture filtrate of Fusarium graminearum respectively. Furthermore, the developed approach is exemplified with nine unknown biochemical compounds contained in F. graminearum samples derived from an untargeted metabolomics experiment. The mass difference between the corresponding fragment ions present in the MS/MS spectra of the native and U-13C-labeled compound enabled the assignment of the number of carbon atoms to each fragment signal and allowed the generation of meaningful putative molecular formulas for each fragment ion, which in turn also helped determine the elemental composition of the precursor ion. Compared to laborious manual analysis of the MS/MS spectra, the presented algorithm marks an important step toward efficient fragment signal elucidation and structure annotation of metabolites in future untargeted metabolomics studies. Moreover, as demonstrated for a fungal culture sample, FragExtract also assists the characterization of unknown metabolites, which are not contained in databases, and thus exhibits a significant contribution to untargeted metabolomics research. PMID:24965664

  16. Quantifying MMA by SLE LC-MS/MS: Unexpected challenges in assay development.

    PubMed

    Lo, Sheng-Ying; Gordon, Cindy; Sadilkova, Katerina; Jack, Rhona M; Dickerson, Jane A

    2016-09-01

    Analysis of serum/plasma methylmalonic acid (MMA) is important for the diagnosis and management of methylmalonic acidemia in pediatric populations. This work focuses on developing and validating a liquid chromatography tandem mass spectrometry (LC-MS/MS) method to monitor methylmalonic acidemia using a simple method preparation. MMA and stable isotope labeled d3-MMA was extracted using supported liquid extraction (SLE). Assay imprecision, bias, linearity, recovery and carryover were determined. The relationship between MMA and propionyl acylcarnitine (C3-acylcarnitine) was also evaluated using historical paired results from 51 unique individuals. Baseline separation between MMA and succinic acid was completed in 7min. The assay was linear from 0.1 to 500μM. The intra-day and inter-day imprecision CV ranged from 4.1 to 13.2% (0.3 to 526μM) and 5.0 to 15.7% (0.3 to 233μM), respectively. Recovery ranged from 93 to 125%. The correlation with a national reference laboratory LC-MS/MS assay showed a Deming regression of 1.026 and intercept of -1.335. Carryover was determined to be <0.04%. Patient-specific correlation was observed between MMA and C3-acylcarnitine. This report describes the first LC-MS/MS method using SLE for MMA extraction. In addition, we illustrate the challenges encountered during this method development that should be assessed and resolved by any laboratory implementing a SLE LC-MS/MS assay designed to quantify analytes across several orders of magnitude. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  17. Simultaneous analysis of 17 diuretics in dietary supplements by HPLC and LC-MS/MS.

    PubMed

    Woo, H; Kim, J W; Han, K M; Lee, J H; Hwang, I S; Lee, J H; Kim, J; Kweon, S J; Cho, S; Chae, K R; Han, S Y; Kim, J

    2013-01-01

    In order to test health foods for illegally added diuretics for weight loss, we developed simple, rapid, selective, and sensitive methods using HPLC and LC-MS/MS for the simultaneous analysis of 17 diuretics in dietary supplements. HPLC conditions were set with a Capcell-pak C18, using a mobile phase consisting of gradient conditions, UV detection at 254 nm and validated for linearity (r(2)> 0.999), precision (CV ≤ 3%), recoveries (90.4-102.8%) and reproducibility. Identification and quantification of 17 diuretics were accomplished by ion-spray LC-MS/MS using multiple reaction monitoring (MRM). The chromatographic separation was carried out under the reversed-phase mechanism on an HSS-T3 column. The LC-MS/MS method was validated for linearity (r(2)> 0.99) and precision (CV < 13%). Sixteen dietary supplements were tested with the developed methods. Diuretics were not detected in all samples. Extraction recovery was also investigated and the extraction recoveries in different formulations were from 88% to 110% and from 81% to 116% using HPLC and LC-MS/MS, respectively. There was no significant difference in recoveries in the type of dietary supplements. Based on this result, the developed methods to monitor illegal drug adulterations in dietary supplements using HPLC and LC-MS/MS are simple, fast and reliable. Therefore, it is applicable to routine drug-adulteration screening.

  18. Evaluation of Normalization Methods on GeLC-MS/MS Label-Free Spectral Counting Data to Correct for Variation during Proteomic Workflows

    NASA Astrophysics Data System (ADS)

    Gokce, Emine; Shuford, Christopher M.; Franck, William L.; Dean, Ralph A.; Muddiman, David C.

    2011-12-01

    Normalization of spectral counts (SpCs) in label-free shotgun proteomic approaches is important to achieve reliable relative quantification. Three different SpC normalization methods, total spectral count (TSpC) normalization, normalized spectral abundance factor (NSAF) normalization, and normalization to selected proteins (NSP) were evaluated based on their ability to correct for day-to-day variation between gel-based sample preparation and chromatographic performance. Three spectral counting data sets obtained from the same biological conidia sample of the rice blast fungus Magnaporthe oryzae were analyzed by 1D gel and liquid chromatography-tandem mass spectrometry (GeLC-MS/MS). Equine myoglobin and chicken ovalbumin were spiked into the protein extracts prior to 1D-SDS- PAGE as internal protein standards for NSP. The correlation between SpCs of the same proteins across the different data sets was investigated. We report that TSpC normalization and NSAF normalization yielded almost ideal slopes of unity for normalized SpC versus average normalized SpC plots, while NSP did not afford effective corrections of the unnormalized data. Furthermore, when utilizing TSpC normalization prior to relative protein quantification, t-testing and fold-change revealed the cutoff limits for determining real biological change to be a function of the absolute number of SpCs. For instance, we observed the variance decreased as the number of SpCs increased, which resulted in a higher propensity for detecting statistically significant, yet artificial, change for highly abundant proteins. Thus, we suggest applying higher confidence level and lower fold-change cutoffs for proteins with higher SpCs, rather than using a single criterion for the entire data set. By choosing appropriate cutoff values to maintain a constant false positive rate across different protein levels (i.e., SpC levels), it is expected this will reduce the overall false negative rate, particularly for proteins with

  19. Data from quantitative label free proteomics analysis of rat spleen.

    PubMed

    Dudekula, Khadar; Le Bihan, Thierry

    2016-09-01

    The dataset presented in this work has been obtained using a label-free quantitative proteomic analysis of rat spleen. A robust method for extraction of proteins from rat spleen tissue and LC-MS-MS analysis was developed using a urea and SDS-based buffer. Different fractionation methods were compared. A total of 3484 different proteins were identified from the pool of all experiments run in this study (a total of 2460 proteins with at least two peptides). A total of 1822 proteins were identified from nine non-fractionated pulse gels, 2288 proteins and 2864 proteins were identified by SDS-PAGE fractionation into three and five fractions respectively. The proteomics data are deposited in ProteomeXchange Consortium via PRIDE PXD003520, Progenesis and Maxquant output are presented in the supported information. The generated list of proteins under different regimes of fractionation allow assessing the nature of the identified proteins; variability in the quantitative analysis associated with the different sampling strategy and allow defining a proper number of replicates for future quantitative analysis.

  20. An Artifact in LC-MS/MS Measurement of Glutamine and Glutamic Acid: In-Source Cyclization to Pyroglutamic Acid

    PubMed Central

    2015-01-01

    Advances in metabolomics, particularly for research on cancer, have increased the demand for accurate, highly sensitive methods for measuring glutamine (Gln) and glutamic acid (Glu) in cell cultures and other biological samples. N-terminal Gln and Glu residues in proteins or peptides have been reported to cyclize to pyroglutamic acid (pGlu) during liquid chromatography (LC)-mass spectrometry (MS) analysis, but cyclization of free Gln and Glu to free pGlu during LC-MS analysis has not been well-characterized. Using an LC-MS/MS protocol that we developed to separate Gln, Glu, and pGlu, we found that free Gln and Glu cyclize to pGlu in the electrospray ionization source, revealing a previously uncharacterized artifact in metabolomic studies. Analysis of Gln standards over a concentration range from 0.39 to 200 μM indicated that a minimum of 33% and maximum of almost 100% of Gln was converted to pGlu in the ionization source, with the extent of conversion dependent on fragmentor voltage. We conclude that the sensitivity and accuracy of Gln, Glu, and pGlu quantitation by electrospray ionization-based mass spectrometry can be improved dramatically by using (i) chromatographic conditions that adequately separate the three metabolites, (ii) isotopic internal standards to correct for in-source pGlu formation, and (iii) user-optimized fragmentor voltage for acquisition of the MS spectra. These findings have immediate impact on metabolomics and metabolism research using LC-MS technologies. PMID:24892977

  1. An artifact in LC-MS/MS measurement of glutamine and glutamic acid: in-source cyclization to pyroglutamic acid.

    PubMed

    Purwaha, Preeti; Silva, Leslie P; Hawke, David H; Weinstein, John N; Lorenzi, Philip L

    2014-06-17

    Advances in metabolomics, particularly for research on cancer, have increased the demand for accurate, highly sensitive methods for measuring glutamine (Gln) and glutamic acid (Glu) in cell cultures and other biological samples. N-terminal Gln and Glu residues in proteins or peptides have been reported to cyclize to pyroglutamic acid (pGlu) during liquid chromatography (LC)-mass spectrometry (MS) analysis, but cyclization of free Gln and Glu to free pGlu during LC-MS analysis has not been well-characterized. Using an LC-MS/MS protocol that we developed to separate Gln, Glu, and pGlu, we found that free Gln and Glu cyclize to pGlu in the electrospray ionization source, revealing a previously uncharacterized artifact in metabolomic studies. Analysis of Gln standards over a concentration range from 0.39 to 200 μM indicated that a minimum of 33% and maximum of almost 100% of Gln was converted to pGlu in the ionization source, with the extent of conversion dependent on fragmentor voltage. We conclude that the sensitivity and accuracy of Gln, Glu, and pGlu quantitation by electrospray ionization-based mass spectrometry can be improved dramatically by using (i) chromatographic conditions that adequately separate the three metabolites, (ii) isotopic internal standards to correct for in-source pGlu formation, and (iii) user-optimized fragmentor voltage for acquisition of the MS spectra. These findings have immediate impact on metabolomics and metabolism research using LC-MS technologies.

  2. Isotope-coded ESI-enhancing derivatization reagents for differential analysis, quantification and profiling of metabolites in biological samples by LC/MS: A review.

    PubMed

    Higashi, Tatsuya; Ogawa, Shoujiro

    2016-10-25

    The analysis of the qualitative and quantitative changes of metabolites in body fluids and tissues yields valuable information for the diagnosis, pathological analysis and treatment of many diseases. Recently, liquid chromatography/electrospray ionization-(tandem) mass spectrometry [LC/ESI-MS(/MS)] has been widely used for these purposes due to the high separation capability of LC, broad coverage of ESI for various compounds and high specificity of MS(/MS). However, there are still two major problems to be solved regarding the biological sample analysis; lack of sensitivity and limited availability of stable isotope-labeled analogues (internal standards, ISs) for most metabolites. Stable isotope-coded derivatization (ICD) can be the answer for these problems. By the ICD, different isotope-coded moieties are introduced to the metabolites and one of the resulting derivatives can serve as the IS, which minimize the matrix effects. Furthermore, the derivatization can improve the ESI efficiency, fragmentation property in the MS/MS and chromatographic behavior of the metabolites, which lead to a high sensitivity and specificity in the various detection modes. Based on this background, this article reviews the recently-reported isotope-coded ESI-enhancing derivatization (ICEED) reagents, which are key components for the ICD-based LC/MS(/MS) studies, and their applications to the detection, identification, quantification and profiling of metabolites in human and animal samples. The LC/MS(/MS) using the ICEED reagents is the powerful method especially for the differential analysis (relative quantification) of metabolites in two comparative samples, simultaneous quantification of multiple metabolites whose stable isotope-labeled ISs are not available, and submetabolome profiling. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Proteomics wants cRacker: automated standardized data analysis of LC-MS derived proteomic data.

    PubMed

    Zauber, Henrik; Schulze, Waltraud X

    2012-11-02

    The large-scale analysis of thousands of proteins under various experimental conditions or in mutant lines has gained more and more importance in hypothesis-driven scientific research and systems biology in the past years. Quantitative analysis by large scale proteomics using modern mass spectrometry usually results in long lists of peptide ion intensities. The main interest for most researchers, however, is to draw conclusions on the protein level. Postprocessing and combining peptide intensities of a proteomic data set requires expert knowledge, and the often repetitive and standardized manual calculations can be time-consuming. The analysis of complex samples can result in very large data sets (lists with several 1000s to 100,000 entries of different peptides) that cannot easily be analyzed using standard spreadsheet programs. To improve speed and consistency of the data analysis of LC-MS derived proteomic data, we developed cRacker. cRacker is an R-based program for automated downstream proteomic data analysis including data normalization strategies for metabolic labeling and label free quantitation. In addition, cRacker includes basic statistical analysis, such as clustering of data, or ANOVA and t tests for comparison between treatments. Results are presented in editable graphic formats and in list files.

  4. Label-free protein quantification using LC-coupled ion trap or FT mass spectrometry: Reproducibility, linearity, and application with complex proteomes.

    PubMed

    Wang, Guanghui; Wu, Wells W; Zeng, Weihua; Chou, Chung-Lin; Shen, Rong-Fong

    2006-05-01

    A critical step in protein biomarker discovery is the ability to contrast proteomes, a process referred generally as quantitative proteomics. While stable-isotope labeling (e.g., ICAT, 18O- or 15N-labeling, or AQUA) remains the core technology used in mass spectrometry-based proteomic quantification, increasing efforts have been directed to the label-free approach that relies on direct comparison of peptide peak areas between LC-MS runs. This latter approach is attractive to investigators for its simplicity as well as cost effectiveness. In the present study, the reproducibility and linearity of using a label-free approach to highly complex proteomes were evaluated. Various amounts of proteins from different proteomes were subjected to repeated LC-MS analyses using an ion trap or Fourier transform mass spectrometer. Highly reproducible data were obtained between replicated runs, as evidenced by nearly ideal Pearson's correlation coefficients (for ion's peak areas or retention time) and average peak area ratios. In general, more than 50% and nearly 90% of the peptide ion ratios deviated less than 10% and 20%, respectively, from the average in duplicate runs. In addition, the multiplicity ratios of the amounts of proteins used correlated nicely with the observed averaged ratios of peak areas calculated from detected peptides. Furthermore, the removal of abundant proteins from the samples led to an improvement in reproducibility and linearity. A computer program has been written to automate the processing of data sets from experiments with groups of multiple samples for statistical analysis. Algorithms for outlier-resistant mean estimation and for adjusting statistical significance threshold in multiplicity of testing were incorporated to minimize the rate of false positives. The program was applied to quantify changes in proteomes of parental and p53-deficient HCT-116 human cells and found to yield reproducible results. Overall, this study demonstrates an alternative

  5. Systematic assessment of survey scan and MS2-based abundance strategies for label-free quantitative proteomics using high-resolution MS data.

    PubMed

    Tu, Chengjian; Li, Jun; Sheng, Quanhu; Zhang, Ming; Qu, Jun

    2014-04-04

    Survey-scan-based label-free method have shown no compelling benefit over fragment ion (MS2)-based approaches when low-resolution mass spectrometry (MS) was used, the growing prevalence of high-resolution analyzers may have changed the game. This necessitates an updated, comparative investigation of these approaches for data acquired by high-resolution MS. Here, we compared survey scan-based (ion current, IC) and MS2-based abundance features including spectral-count (SpC) and MS2 total-ion-current (MS2-TIC), for quantitative analysis using various high-resolution LC/MS data sets. Key discoveries include: (i) study with seven different biological data sets revealed only IC achieved high reproducibility for lower-abundance proteins; (ii) evaluation with 5-replicate analyses of a yeast sample showed IC provided much higher quantitative precision and lower missing data; (iii) IC, SpC, and MS2-TIC all showed good quantitative linearity (R(2) > 0.99) over a >1000-fold concentration range; (iv) both MS2-TIC and IC showed good linear response to various protein loading amounts but not SpC; (v) quantification using a well-characterized CPTAC data set showed that IC exhibited markedly higher quantitative accuracy, higher sensitivity, and lower false-positives/false-negatives than both SpC and MS2-TIC. Therefore, IC achieved an overall superior performance than the MS2-based strategies in terms of reproducibility, missing data, quantitative dynamic range, quantitative accuracy, and biomarker discovery.

  6. Systematic Assessment of Survey Scan and MS2-Based Abundance Strategies for Label-Free Quantitative Proteomics Using High-Resolution MS Data

    PubMed Central

    2015-01-01

    Survey-scan-based label-free method have shown no compelling benefit over fragment ion (MS2)-based approaches when low-resolution mass spectrometry (MS) was used, the growing prevalence of high-resolution analyzers may have changed the game. This necessitates an updated, comparative investigation of these approaches for data acquired by high-resolution MS. Here, we compared survey scan-based (ion current, IC) and MS2-based abundance features including spectral-count (SpC) and MS2 total-ion-current (MS2-TIC), for quantitative analysis using various high-resolution LC/MS data sets. Key discoveries include: (i) study with seven different biological data sets revealed only IC achieved high reproducibility for lower-abundance proteins; (ii) evaluation with 5-replicate analyses of a yeast sample showed IC provided much higher quantitative precision and lower missing data; (iii) IC, SpC, and MS2-TIC all showed good quantitative linearity (R2 > 0.99) over a >1000-fold concentration range; (iv) both MS2-TIC and IC showed good linear response to various protein loading amounts but not SpC; (v) quantification using a well-characterized CPTAC data set showed that IC exhibited markedly higher quantitative accuracy, higher sensitivity, and lower false-positives/false-negatives than both SpC and MS2-TIC. Therefore, IC achieved an overall superior performance than the MS2-based strategies in terms of reproducibility, missing data, quantitative dynamic range, quantitative accuracy, and biomarker discovery. PMID:24635752

  7. Urine Multi-drug Screening with GC-MS or LC-MS-MS Using SALLE-hybrid PPT/SPE.

    PubMed

    Lee, Junhui; Park, Jiwon; Go, Ahra; Moon, Heesung; Kim, Sujin; Jung, Sohee; Jeong, Wonjoon; Chung, Heesun

    2018-05-14

    To intoxicated patients in the emergency room, toxicological analysis can be considerably helpful for identifying the involved toxicants. In order to develop a urine multi-drug screening (UmDS) method, gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) were used to determine targeted and unknown toxicants in urine. A GC-MS method in scan mode was validated for selectivity, limit of detection (LOD) and recovery. An LC-MS-MS multiple reaction monitoring (MRM) method was validated for lower LOD, recovery and matrix effect. The results of the screening analysis were compared with patient medical records to check the reliability of the screen. Urine samples collected from an emergency room were extracted through a combination of salting-out assisted liquid-liquid extraction (SALLE) and hybrid protein precipitation/solid phase extraction (hybrid PPT/SPE) plates and examined by GC-MS and LC-MS-MS. GC-MS analysis was performed as unknown drug screen and LC-MS-MS analysis was conducted as targeted drug screen. After analysis by GC-MS, a library search was conducted using an in-house library established with the automated mass spectral deconvolution and identification system (AMDISTM). LC-MS-MS used Cliquid®2.0 software for data processing and acquisition in MRM mode. An UmDS method by GC-MS and LC-MS-MS was developed by using a SALLE-hybrid PPT/SPE and in-house library. The results of UmDS by GC-MS and LC-MS-MS showed that toxicants could be identified from 185 emergency room patient samples containing unknown toxicants. Zolpidem, acetaminophen and citalopram were the most frequently encountered drugs in emergency room patients. The UmDS analysis developed in this study can be used effectively to detect toxic substances in a short time. Hence, it could be utilized in clinical and forensic toxicology practices.

  8. Accurate LC Peak Boundary Detection for 16 O/ 18 O Labeled LC-MS Data

    PubMed Central

    Cui, Jian; Petritis, Konstantinos; Tegeler, Tony; Petritis, Brianne; Ma, Xuepo; Jin, Yufang; Gao, Shou-Jiang (SJ); Zhang, Jianqiu (Michelle)

    2013-01-01

    In liquid chromatography-mass spectrometry (LC-MS), parts of LC peaks are often corrupted by their co-eluting peptides, which results in increased quantification variance. In this paper, we propose to apply accurate LC peak boundary detection to remove the corrupted part of LC peaks. Accurate LC peak boundary detection is achieved by checking the consistency of intensity patterns within peptide elution time ranges. In addition, we remove peptides with erroneous mass assignment through model fitness check, which compares observed intensity patterns to theoretically constructed ones. The proposed algorithm can significantly improve the accuracy and precision of peptide ratio measurements. PMID:24115998

  9. Definitive screening design enables optimization of LC-ESI-MS/MS parameters in proteomics.

    PubMed

    Aburaya, Shunsuke; Aoki, Wataru; Minakuchi, Hiroyoshi; Ueda, Mitsuyoshi

    2017-12-01

    In proteomics, more than 100,000 peptides are generated from the digestion of human cell lysates. Proteome samples have a broad dynamic range in protein abundance; therefore, it is critical to optimize various parameters of LC-ESI-MS/MS to comprehensively identify these peptides. However, there are many parameters for LC-ESI-MS/MS analysis. In this study, we applied definitive screening design to simultaneously optimize 14 parameters in the operation of monolithic capillary LC-ESI-MS/MS to increase the number of identified proteins and/or the average peak area of MS1. The simultaneous optimization enabled the determination of two-factor interactions between LC and MS. Finally, we found two parameter sets of monolithic capillary LC-ESI-MS/MS that increased the number of identified proteins by 8.1% or the average peak area of MS1 by 67%. The definitive screening design would be highly useful for high-throughput analysis of the best parameter set in LC-ESI-MS/MS systems.

  10. Analysis of benzodiazepines and their metabolites using DBS cards and LC-MS/MS.

    PubMed

    Lee, Heesang; Park, Yujin; Jo, Jiyeong; In, Sangwhan; Park, Yonghoon; Kim, Eunmi; Pyo, Jaesung; Choe, Sanggil

    2015-10-01

    Dried Blood Spot (DBS) has been used a blood extraction method for inherited metabolic disorder screening since 1960s. With introduction of LC-MS/MS, not only DBS could be used to analysis drugs in small blood volume, but in various fields, such as toxicology, drug therapeutic monitoring, drug diagnostic screening, and illicit drugs. In toxicology field, many drugs (e.g. benzodiazepines, acetaminophen, small molecule drugs) have been tested with DBS. Compared with earlier blood extraction methods (SPE and LLE), DBS has lots of advantages; lower blood volume (less than 50μL), shorter analysis time caused by a more concise analysis procedure and lower cost. We optimized the DBS procedure and LC-MS/MS conditions for 18 benzodiazepines, seven benzodiazepine metabolites, and one z-drug (zolpidem) analysis in blood. 30μL of whole blood was spotted on FTA DMPK card C and dried for 2h in a desiccator. A 6-mm disk was punched and vortexed for 1min in a centrifuge tube with 300μL methanol/acetonitrile mixture (1:1, v/v). After evaporation, redissolved in 100μL mobile phase of LC-MS/MS and 5μL was injected. In the analysis for 26 target compounds in blood, all of the method validation parameters - LLOD, LLOQ, accuracy (intra- and inter-assay), and precision (intra- and inter-assay) - were satisfied with method validation criteria, within 15%. The results of matrix effect, recovery, and process efficiency were good. We developed a fast and reliable sample preparation method using DBS for 26 benzodiazepines, benzodiazepine metabolites, and z-drug (zolpidem). Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. iPhos: a toolkit to streamline the alkaline phosphatase-assisted comprehensive LC-MS phosphoproteome investigation

    PubMed Central

    2014-01-01

    Background Comprehensive characterization of the phosphoproteome in living cells is critical in signal transduction research. But the low abundance of phosphopeptides among the total proteome in cells remains an obstacle in mass spectrometry-based proteomic analysis. To provide a solution, an alternative analytic strategy to confidently identify phosphorylated peptides by using the alkaline phosphatase (AP) treatment combined with high-resolution mass spectrometry was provided. While the process is applicable, the key integration along the pipeline was mostly done by tedious manual work. Results We developed a software toolkit, iPhos, to facilitate and streamline the work-flow of AP-assisted phosphoproteome characterization. The iPhos tookit includes one assister and three modules. The iPhos Peak Extraction Assister automates the batch mode peak extraction for multiple liquid chromatography mass spectrometry (LC-MS) runs. iPhos Module-1 can process the peak lists extracted from the LC-MS analyses derived from the original and dephosphorylated samples to mine out potential phosphorylated peptide signals based on mass shift caused by the loss of some multiples of phosphate groups. And iPhos Module-2 provides customized inclusion lists with peak retention time windows for subsequent targeted LC-MS/MS experiments. Finally, iPhos Module-3 facilitates to link the peptide identifications from protein search engines to the quantification results from pattern-based label-free quantification tools. We further demonstrated the utility of the iPhos toolkit on the data of human metastatic lung cancer cells (CL1-5). Conclusions In the comparison study of the control group of CL1-5 cell lysates and the treatment group of dasatinib-treated CL1-5 cell lysates, we demonstrated the applicability of the iPhos toolkit and reported the experimental results based on the iPhos-facilitated phosphoproteome investigation. And further, we also compared the strategy with pure DDA-based LC-MS/MS

  12. Mass spectrometry data from label-free quantitative proteomic analysis of harmless and pathogenic strains of infectious microalgae, Prototheca spp.

    PubMed

    Murugaiyan, Jayaseelan; Eravci, Murat; Weise, Christoph; Roesler, Uwe

    2017-06-01

    Here, we provide the dataset associated with our research article 'label-free quantitative proteomic analysis of harmless and pathogenic strains of infectious microalgae, Prototheca spp.' (Murugaiyan et al., 2017) [1]. This dataset describes liquid chromatography-mass spectrometry (LC-MS)-based protein identification and quantification of a non-infectious strain, Prototheca zopfii genotype 1 and two strains associated with severe and mild infections, respectively, P. zopfii genotype 2 and Prototheca blaschkeae . Protein identification and label-free quantification was carried out by analysing MS raw data using the MaxQuant-Andromeda software suit. The expressional level differences of the identified proteins among the strains were computed using Perseus software and the results were presented in [1]. This DiB provides the MaxQuant output file and raw data deposited in the PRIDE repository with the dataset identifier PXD005305.

  13. Amino acid analysis in physiological samples by GC-MS with propyl chloroformate derivatization and iTRAQ-LC-MS/MS.

    PubMed

    Dettmer, Katja; Stevens, Axel P; Fagerer, Stephan R; Kaspar, Hannelore; Oefner, Peter J

    2012-01-01

    Two mass spectrometry-based methods for the quantitative analysis of free amino acids are described. The first method uses propyl chloroformate/propanol derivatization and gas chromatography-quadrupole mass spectrometry (GC-qMS) analysis in single-ion monitoring mode. Derivatization is carried out directly in aqueous samples, thereby allowing automation of the entire procedure, including addition of reagents, extraction, and injection into the GC-MS. The method delivers the quantification of 26 amino acids. The isobaric tagging for relative and absolute quantification (iTRAQ) method employs the labeling of amino acids with isobaric iTRAQ tags. The tags contain two different cleavable reporter ions, one for the sample and one for the standard, which are detected by fragmentation in a tandem mass spectrometer. Reversed-phase liquid chromatography of the labeled amino acids is performed prior to mass spectrometric analysis to separate isobaric amino acids. The commercial iTRAQ kit allows for the analysis of 42 physiological amino acids with a respective isotope-labeled standard for each of these 42 amino acids.

  14. Matrix effects break the LC behavior rule for analytes in LC-MS/MS analysis of biological samples

    USDA-ARS?s Scientific Manuscript database

    High-performance liquid chromatography (HPLC) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) are generally accepted as the preferred techniques for detecting and quantitating analytes of interest in biological matrices on the basis of the rule that one chemical compound yields one LC-...

  15. MetExtract: a new software tool for the automated comprehensive extraction of metabolite-derived LC/MS signals in metabolomics research.

    PubMed

    Bueschl, Christoph; Kluger, Bernhard; Berthiller, Franz; Lirk, Gerald; Winkler, Stephan; Krska, Rudolf; Schuhmacher, Rainer

    2012-03-01

    Liquid chromatography-mass spectrometry (LC/MS) is a key technique in metabolomics. Since the efficient assignment of MS signals to true biological metabolites becomes feasible in combination with in vivo stable isotopic labelling, our aim was to provide a new software tool for this purpose. An algorithm and a program (MetExtract) have been developed to search for metabolites in in vivo labelled biological samples. The algorithm makes use of the chromatographic characteristics of the LC/MS data and detects MS peaks fulfilling the criteria of stable isotopic labelling. As a result of all calculations, the algorithm specifies a list of m/z values, the corresponding number of atoms of the labelling element (e.g. carbon) together with retention time and extracted adduct-, fragment- and polymer ions. Its function was evaluated using native (12)C- and uniformly (13)C-labelled standard substances. MetExtract is available free of charge and warranty at http://code.google.com/p/metextract/. Precompiled executables are available for Windows operating systems. Supplementary data are available at Bioinformatics online.

  16. Comparison of sample preparation techniques and data analysis for the LC-MS/MS-based identification of proteins in human follicular fluid.

    PubMed

    Lehmann, Roland; Schmidt, André; Pastuschek, Jana; Müller, Mario M; Fritzsche, Andreas; Dieterle, Stefan; Greb, Robert R; Markert, Udo R; Slevogt, Hortense

    2018-06-25

    The proteomic analysis of complex body fluids by liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis requires the selection of suitable sample preparation techniques and optimal parameter settings in data analysis software packages to obtain reliable results. Proteomic analysis of follicular fluid, as a representative of a complex body fluid similar to serum or plasma, is difficult as it contains a vast amount of high abundant proteins and a variety of proteins with different concentrations. However, the accessibility of this complex body fluid for LC-MS/MS analysis is an opportunity to gain insights into the status, the composition of fertility-relevant proteins including immunological factors or for the discovery of new diagnostic and prognostic markers for, for example, the treatment of infertility. In this study, we compared different sample preparation methods (FASP, eFASP and in-solution digestion) and three different data analysis software packages (Proteome Discoverer with SEQUEST, Mascot and MaxQuant with Andromeda) combined with semi- and full-tryptic databank search options to obtain a maximum coverage of the follicular fluid proteome. We found that the most comprehensive proteome coverage is achieved by the eFASP sample preparation method using SDS in the initial denaturing step and the SEQUEST-based semi-tryptic data analysis. In conclusion, we have developed a fractionation-free methodical workflow for in depth LC-MS/MS-based analysis for the standardized investigation of human follicle fluid as an important representative of a complex body fluid. Taken together, we were able to identify a total of 1392 proteins in follicular fluid. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Simultaneous quantitative analysis of nine vitamin D compounds in human blood using LC-MS/MS.

    PubMed

    Abu Kassim, Nur Sofiah; Gomes, Fabio P; Shaw, Paul Nicholas; Hewavitharana, Amitha K

    2016-01-01

    It has been suggested that each member of the family of vitamin D compounds may have different function(s). Therefore, selective quantification of each compound is important in clinical research. Development and validation attempts of a simultaneous determination method of 12 vitamin D compounds in human blood using precolumn derivatization followed by LC-MS/MS is described. Internal standard calibration with 12 stable isotope labeled analogs was used to correct for matrix effects in MS detector. Nine vitamin D compounds were quantifiable in blood samples with detection limits within femtomole levels. Serum (compared with plasma) was found to be a more suitable sample type, and protein precipitation (compared with saponification) a more effective extraction method for vitamin D assay.

  18. Characterization of a mixture of lobster digestive cysteine proteinases by ionspray mass spectrometry and tryptic mapping with LC--MS and LC--MS--MS

    NASA Astrophysics Data System (ADS)

    Thibault, P.; Pleasance, S.; Laycock, M. V.; Mackay, R. M.; Boyd, R. K.

    1991-12-01

    An inseparable mixture of two cysteine proteinases, isolated from the digestive tract of the American lobster, was investigated by ionspray mass spectrometry (ISP-MS), using a combination of infusion of intact proteins with on-line liquid chromatography--mass spectrometry (LC--MS) and LC--MS--MS analyses of tryptic digests. These data were interpreted by comparisons with predictions from results of molecular cloning of cysteine-proteinase-encoding messenger RNA sequences previously isolated from the lobster hepatopancreas. Investigations of the numbers of free thiol groups and of disulfide bonds were made by measuring the molecular weights of the alkylated proteins with and without prior reduction of disulfide bonds, and comparison with the corresponding data for the native proteins. Identification of tyrptic fragment peptides containing cysteine residues was facilitated by comparing LC--MS analyses of tryptic digests of denatured and of denatured and alkylated proteins, since such tryptic peptides are subject to shifts in both mass and retention time upon reduction and alkylation. Confirmation of amino acid sequences was obtained from fragment ion spectra of each tryptic peptide (alkylated or not) as it eluted from the column. Acquisition of such on-line LC--MS data was possible through use of the entire effluent from a standard 1 mm high performance liquid chromatography (HPLC) column by an IonsSpray® LC--MS interface (pneumatically assisted electrospray).

  19. Analysis of catecholamines in urine by unique LC/MS suitable ion-pairing chromatography.

    PubMed

    Bergmann, Marianne L; Sadjadi, Seyed; Schmedes, Anne

    2017-07-01

    The catecholamines, epinephrine (E) and norepinephrine (NE) are small polar, hydrophilic molecules, posing significant challenges to liquid chromatography - tandem mass spectrometry (LC-MS/MS) method development. Specifically, these compounds show little retention on conventional reversed-phase liquid chromatography columns. This work presents development and validation of an LC-MS/MS method for determining catecholamines in urine, based on a new approach to ion-pairing chromatography (IPC), in which the ion-pairing reagent (IPR), 1-Heptane Sulfonic Acid (HSA), is added to the extracted samples instead of the mobile phases. A Hamilton STARlet workstation carried out the solid phase extraction of urine samples. The extracted samples were diluted with 60mmol/L HSA and injected on a Kinetex core-shell biphenyl column with conventional LC-MS/MS suitable mobile phases. Chromatographic separation of E and NE was achieved successfully with very stable retention times (RT). In 484 injections, the RTs were steady with a CV of less than ±4%. Furthermore, HSA was separated from E and NE, allowing HSA to be diverted to waste instead of entering the mass spectrometer ion chamber. The method was validated with good analytical performance, and even though the analysis for urinary catecholamines is increasingly being replaced by plasma free metanephrines in diagnosing pheochromocytomas, this work represents the application of a new analytical technique that can be transferred to other small polar molecules, that are difficult to chromatograph on traditional reversed phase columns. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. A Guideline to Univariate Statistical Analysis for LC/MS-Based Untargeted Metabolomics-Derived Data

    PubMed Central

    Vinaixa, Maria; Samino, Sara; Saez, Isabel; Duran, Jordi; Guinovart, Joan J.; Yanes, Oscar

    2012-01-01

    Several metabolomic software programs provide methods for peak picking, retention time alignment and quantification of metabolite features in LC/MS-based metabolomics. Statistical analysis, however, is needed in order to discover those features significantly altered between samples. By comparing the retention time and MS/MS data of a model compound to that from the altered feature of interest in the research sample, metabolites can be then unequivocally identified. This paper reports on a comprehensive overview of a workflow for statistical analysis to rank relevant metabolite features that will be selected for further MS/MS experiments. We focus on univariate data analysis applied in parallel on all detected features. Characteristics and challenges of this analysis are discussed and illustrated using four different real LC/MS untargeted metabolomic datasets. We demonstrate the influence of considering or violating mathematical assumptions on which univariate statistical test rely, using high-dimensional LC/MS datasets. Issues in data analysis such as determination of sample size, analytical variation, assumption of normality and homocedasticity, or correction for multiple testing are discussed and illustrated in the context of our four untargeted LC/MS working examples. PMID:24957762

  1. A Guideline to Univariate Statistical Analysis for LC/MS-Based Untargeted Metabolomics-Derived Data.

    PubMed

    Vinaixa, Maria; Samino, Sara; Saez, Isabel; Duran, Jordi; Guinovart, Joan J; Yanes, Oscar

    2012-10-18

    Several metabolomic software programs provide methods for peak picking, retention time alignment and quantification of metabolite features in LC/MS-based metabolomics. Statistical analysis, however, is needed in order to discover those features significantly altered between samples. By comparing the retention time and MS/MS data of a model compound to that from the altered feature of interest in the research sample, metabolites can be then unequivocally identified. This paper reports on a comprehensive overview of a workflow for statistical analysis to rank relevant metabolite features that will be selected for further MS/MS experiments. We focus on univariate data analysis applied in parallel on all detected features. Characteristics and challenges of this analysis are discussed and illustrated using four different real LC/MS untargeted metabolomic datasets. We demonstrate the influence of considering or violating mathematical assumptions on which univariate statistical test rely, using high-dimensional LC/MS datasets. Issues in data analysis such as determination of sample size, analytical variation, assumption of normality and homocedasticity, or correction for multiple testing are discussed and illustrated in the context of our four untargeted LC/MS working examples.

  2. Twoplex 12/13 C6 aniline stable isotope and linkage-specific sialic acid labeling 2D-LC-MS workflow for quantitative N-glycomics.

    PubMed

    Albrecht, Simone; Mittermayr, Stefan; Smith, Josh; Martín, Silvia Millán; Doherty, Margaret; Bones, Jonathan

    2017-01-01

    Quantitative glycomics represents an actively expanding research field ranging from the discovery of disease-associated glycan alterations to the quantitative characterization of N-glycans on therapeutic proteins. Commonly used analytical platforms for comparative relative quantitation of complex glycan samples include MALDI-TOF-MS or chromatographic glycan profiling with subsequent data alignment and statistical evaluation. Limitations of such approaches include run-to-run technical variation and the potential introduction of subjectivity during data processing. Here, we introduce an offline 2D LC-MS E workflow for the fractionation and relative quantitation of twoplex isotopically labeled N-linked oligosaccharides using neutral 12 C 6 and 13 C 6 aniline (Δmass = 6 Da). Additional linkage-specific derivatization of sialic acids using 4-(4,6-dimethoxy-1,3,5-trizain-2-yl)-4-methylmorpholinium chloride offered simultaneous and advanced in-depth structural characterization. The potential of the method was demonstrated for the differential analysis of structurally defined N-glycans released from serum proteins of patients diagnosed with various stages of colorectal cancer. The described twoplex 12 C 6 / 13 C 6 aniline 2D LC-MS platform is ideally suited for differential glycomic analysis of structurally complex N-glycan pools due to combination and analysis of samples in a single LC-MS injection and the associated minimization in technical variation. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Preservation of urine free catecholamines and their free O-methylated metabolites with citric acid as an alternative to hydrochloric acid for LC-MS/MS-based analyses.

    PubMed

    Peitzsch, Mirko; Pelzel, Daniela; Lattke, Peter; Siegert, Gabriele; Eisenhofer, Graeme

    2016-01-01

    Measurements of urinary fractionated metadrenalines provide a useful screening test to diagnose phaeochromocytoma. Stability of these compounds and their parent catecholamines during and after urine collection is crucial to ensure accuracy of the measurements. Stabilisation with hydrochloric acid (HCl) can promote deconjugation of sulphate-conjugated metadrenalines, indicating a need for alternative preservatives. Urine samples with an intrinsically acidic or alkaline pH (5.5-6.9 or 7.1-8.7, respectively) were used to assess stability of free catecholamines and their free O-methylated metabolites over 7 days of room temperature storage. Stabilisation with HCl was compared with ethylenediaminetetraacetic acid/metabisulphite and monobasic citric acid. Catecholamines and metabolites were measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Free catecholamines and their O-methylated metabolites were stable in acidic urine samples over 7 days of room temperature storage, independent of the presence or absence of any stabilisation method. In contrast, free catecholamines, but not the free O-methylated metabolites, showed rapid degradation within 24 h and continuing degradation over 7 days in urine samples with an alkaline pH. Adjustment of alkaline urine samples to a pH of 3-5 with HCl or 4.8-5.4 with citric acid completely blocked degradation of catecholamines. Ethylenediaminetetraacetic acid/metabisulphite, although reducing the extent of degradation of catecholamines in alkaline urine, was largely ineffectual as a stabiliser. Citric acid is equally effective as HCl for stabilisation of urinary free catecholamines and minimises hazards associated with use of strong inorganic acids while avoiding deconjugation of sulphate-conjugated metabolites during simultaneous LC-MS/MS measurements of free catecholamines and their free O-methylated metabolites.

  4. Comprehensive Analysis of LC/MS Data Using Pseudocolor Plots

    NASA Astrophysics Data System (ADS)

    Crutchfield, Christopher A.; Olson, Matthew T.; Gourgari, Evgenia; Nesterova, Maria; Stratakis, Constantine A.; Yergey, Alfred L.

    2013-02-01

    We have developed new applications of the pseudocolor plot for the analysis of LC/MS data. These applications include spectral averaging, analysis of variance, differential comparison of spectra, and qualitative filtering by compound class. These applications have been motivated by the need to better understand LC/MS data generated from analysis of human biofluids. The examples presented use data generated to profile steroid hormones in urine extracts from a Cushing's disease patient relative to a healthy control, but are general to any discovery-based scanning mass spectrometry technique. In addition to new visualization techniques, we introduce a new metric of variance: the relative maximum difference from the mean. We also introduce the concept of substructure-dependent analysis of steroid hormones using precursor ion scans. These new analytical techniques provide an alternative approach to traditional untargeted metabolomics workflow. We present an approach to discovery using MS that essentially eliminates alignment or preprocessing of spectra. Moreover, we demonstrate the concept that untargeted metabolomics can be achieved using low mass resolution instrumentation.

  5. Determination of Free and Total Choline and Carnitine in Infant Formula and Adult/Pediatric Nutritional Formula by Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS): Single-Laboratory Validation, First Action 2015.10.

    PubMed

    Ellingson, David J; Shippar, Jeffrey J; Gilmore, Justin M

    2016-01-01

    Analytical methods for the analysis of both L-carnitine and choline are needed for reliable and accurate determination in infant formula and adult/pediatric nutritional formula. These compounds are different in how they are utilized by the human body, but are structurally similar. L-carnitine and choline are quaternary ammonium compounds, enabling both to be retained under acidic conditions with strong cation exchange (SCX) chromatography. This method analyzes both compounds simultaneously as either the free forms or as a total amount that includes bound sources such as phosphatidylcholine or acetylcarnitine. The free analysis consists of water extraction and analysis by LC/MS/MS, while the total analysis consists of extraction by acid assisted microwave hydrolysis and analysis by LC/MS/MS. Calibration standards used for calculations are extracted with all samples in the batch. A single laboratory validation (SLV) was performed following the guidelines of the AOAC Stakeholder Panel on Infant Formula and Adult Nutritionals (SPIFAN) utilizing the kit of materials provided. The results achieved meet the requirements of SMPR 2012.010 and 2012.013 for L-carnitine and total choline, respectively.

  6. Measurement of deuterium-labeled phylloquinone in plasma by LC-APCI-MS

    USDA-ARS?s Scientific Manuscript database

    Deuterium-labeled vegetables were fed to humans for the measurement of both unlabeled and deuterium-labeled phylloquinone in plasma. We developed a technique to determine the quantities of these compounds using liquid chromatography/mass spectrometry with atmospheric pressure chemical ionization (LC...

  7. Nano-LC/MALDI-MS using a column-integrated spotting probe for analysis of complex biomolecule samples.

    PubMed

    Hioki, Yusaku; Tanimura, Ritsuko; Iwamoto, Shinichi; Tanaka, Koichi

    2014-03-04

    Nanoflow liquid chromatography (nano-LC) is an essential technique for highly sensitive analysis of complex biological samples, and matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is advantageous for rapid identification of proteins and in-depth analysis of post-translational modifications (PTMs). A combination of nano-LC and MALDI-MS (nano-LC/MALDI-MS) is useful for highly sensitive and detailed analysis in life sciences. However, the existing system does not fully utilize the advantages of each technique, especially in the interface of eluate transfer from nano-LC to a MALDI plate. To effectively combine nano-LC with MALDI-MS, we integrated a nano-LC column and a deposition probe for the first time (column probe) and incorporated it into a nano-LC/MALDI-MS system. Spotting nanoliter eluate droplets directly from the column onto the MALDI plate prevents postcolumn diffusion and preserves the chromatographic resolution. A DHB prespotted plate was prepared to suit the fabricated column probe to concentrate the droplets of nano-LC eluate. The performance of the advanced nano-LC/MALDI-MS system was substantiated by analyzing protein digests. When the system was coupled with multidimensional liquid chromatography (MDLC), trace amounts of glycopeptides that spiked into complex samples were successfully detected. Thus, a nano-LC/MALDI-MS direct-spotting system that eliminates postcolumn diffusion was constructed, and the efficacy of the system was demonstrated through highly sensitive analysis of the protein digests or spiked glycopeptides.

  8. Quantitative determination of free/bound atazanavir via high-throughput equilibrium dialysis and LC-MS/MS, and the application in ex vivo samples.

    PubMed

    Xu, Xiaohui Sophia; Rose, Anne; Demers, Roger; Eley, Timothy; Ryan, John; Stouffer, Bruce; Cojocaru, Laura; Arnold, Mark

    2014-01-01

    The determination of drug-protein binding is important in the pharmaceutical development process because of the impact of protein binding on both the pharmacokinetics and pharmacodynamics of drugs. Equilibrium dialysis is the preferred method to measure the free drug fraction because it is considered to be more accurate. The throughput of equilibrium dialysis has recently been improved by implementing a 96-well format plate. Results/methodology: This manuscript illustrates the successful application of a 96-well rapid equilibrium dialysis (RED) device in the determination of atazanavir plasma-protein binding. This RED method of measuring free fraction was successfully validated and then applied to the analysis of clinical plasma samples taken from HIV-infected pregnant women administered atazanavir. Combined with LC-MS/MS detection, the 96-well format equilibrium dialysis device was suitable for measuring the free and bound concentration of pharmaceutical molecules in a high-throughput mode.

  9. Accurate LC peak boundary detection for ¹⁶O/¹⁸O labeled LC-MS data.

    PubMed

    Cui, Jian; Petritis, Konstantinos; Tegeler, Tony; Petritis, Brianne; Ma, Xuepo; Jin, Yufang; Gao, Shou-Jiang S J; Zhang, Jianqiu Michelle

    2013-01-01

    In liquid chromatography-mass spectrometry (LC-MS), parts of LC peaks are often corrupted by their co-eluting peptides, which results in increased quantification variance. In this paper, we propose to apply accurate LC peak boundary detection to remove the corrupted part of LC peaks. Accurate LC peak boundary detection is achieved by checking the consistency of intensity patterns within peptide elution time ranges. In addition, we remove peptides with erroneous mass assignment through model fitness check, which compares observed intensity patterns to theoretically constructed ones. The proposed algorithm can significantly improve the accuracy and precision of peptide ratio measurements.

  10. Development of Chemical Isotope Labeling LC-MS for Milk Metabolomics: Comprehensive and Quantitative Profiling of the Amine/Phenol Submetabolome.

    PubMed

    Mung, Dorothea; Li, Liang

    2017-04-18

    Milk is a complex sample containing a variety of proteins, lipids, and metabolites. Studying the milk metabolome represents an important application of metabolomics in the general area of nutritional research. However, comprehensive and quantitative analysis of milk metabolites is a challenging task due to the wide range of variations in chemical/physical properties and concentrations of these metabolites. We report an analytical workflow for in-depth profiling of the milk metabolome based on chemical isotope labeling (CIL) and liquid chromatography mass spectrometry (LC-MS) with a focus of using dansylation labeling to target the amine/phenol submetabolome. An optimal sample preparation method, including the use of methanol at a 3:1 ratio of solvent to milk for protein precipitation and dichloromethane for lipid removal, was developed to detect and quantify as many metabolites as possible. This workflow was found to be generally applicable to profile milk metabolomes of different species (cow, goat, and human) and types. Results from experimental replicate analysis (n = 5) of 1:1, 2:1, and 1:2 12 C-/ 13 C-labeled cow milk samples showed that 95.7%, 94.3%, and 93.2% of peak pairs, respectively, had ratio values within ±50% accuracy range and 90.7%, 92.6%, and 90.8% peak pairs had RSD values of less than 20%. In the metabolomic analysis of 36 samples from different categories of cow milk (brands, batches, and fat percentages) with experimental triplicates, a total of 7104 peak pairs or metabolites could be detected with an average of 4573 ± 505 (n = 108) pairs detected per LC-MS run. Among them, 3820 peak pairs were commonly detected in over 80% of the samples with 70 metabolites positively identified by mass and retention time matches to the dansyl standard library and 2988 pairs with their masses matched to the human metabolome libraries. This unprecedentedly high coverage of the amine/phenol submetabolome illustrates the complexity of the milk metabolome. Since

  11. Simultaneous determination of creatinine and creatine in human serum by double-spike isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS).

    PubMed

    Fernández-Fernández, Mario; Rodríguez-González, Pablo; Añón Álvarez, M Elena; Rodríguez, Felix; Menéndez, Francisco V Álvarez; García Alonso, J Ignacio

    2015-04-07

    This work describes the first multiple spiking isotope dilution procedure for organic compounds using (13)C labeling. A double-spiking isotope dilution method capable of correcting and quantifying the creatine-creatinine interconversion occurring during the analytical determination of both compounds in human serum is presented. The determination of serum creatinine may be affected by the interconversion between creatine and creatinine during sample preparation or by inefficient chemical separation of those compounds by solid phase extraction (SPE). The methodology is based on the use differently labeled (13)C analogues ((13)C1-creatinine and (13)C2-creatine), the measurement of the isotopic distribution of creatine and creatinine by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and the application of multiple linear regression. Five different lyophilized serum-based controls and two certified human serum reference materials (ERM-DA252a and ERM-DA253a) were analyzed to evaluate the accuracy and precision of the proposed double-spike LC-MS/MS method. The methodology was applied to study the creatine-creatinine interconversion during LC-MS/MS and gas chromatography-mass spectrometry (GC-MS) analyses and the separation efficiency of the SPE step required in the traditional gas chromatography-isotope dilution mass spectrometry (GC-IDMS) reference methods employed for the determination of serum creatinine. The analysis of real serum samples by GC-MS showed that creatine-creatinine separation by SPE can be a nonquantitative step that may induce creatinine overestimations up to 28% in samples containing high amounts of creatine. Also, a detectable conversion of creatine into creatinine was observed during sample preparation for LC-MS/MS. The developed double-spike LC-MS/MS improves the current state of the art for the determination of creatinine in human serum by isotope dilution mass spectrometry (IDMS), because corrections are made for all the possible errors

  12. General Unknown Screening by Ion Trap LC/MS/MS

    DTIC Science & Technology

    2010-04-01

    Subtitle 5 . Report Date April 2010 General Unknown Screening by Ion Trap LC/MS/MS 6 . Performing Organization Code 7. Author(s) 8... 5 Table 1: Analytical Data for Each of the...359 Compounds in the LC/MS/MS Library . . . . . . . . . . . 6 1 General Unknown ScreeninG by ion Trap lc/MS/MS INTrOduCTION The Federal Aviation

  13. Chemical Isotope Labeling LC-MS for Monitoring Disease Progression and Treatment in Animal Models: Plasma Metabolomics Study of Osteoarthritis Rat Model

    NASA Astrophysics Data System (ADS)

    Chen, Deying; Su, Xiaoling; Wang, Nan; Li, Yunong; Yin, Hua; Li, Liang; Li, Lanjuan

    2017-01-01

    We report a chemical isotope labeling (CIL) liquid chromatography mass spectrometry (LC-MS) method generally applicable for tracking metabolomic changes from samples collected in an animal model for studying disease development and treatment. A rat model of surgically induced osteoarthritis (OA) was used as an example to illustrate the workflow and technical performance. Experimental duplicate analyses of 234 plasma samples were carried out using dansylation labeling LC-MS targeting the amine/phenol submetabolome. These samples composed of 39 groups (6 rats per group) were collected at multiple time points with sham operation, OA control group, and OA rats with treatment, separately, using glucosamine/Celecoxib and three traditional Chinese medicines (Epimedii folium, Chuanxiong Rhizoma and Bushen-Huoxue). In total, 3893 metabolites could be detected and 2923 of them were consistently detected in more than 50% of the runs. This high-coverage submetabolome dataset could be used to track OA progression and treatment. Many differentiating metabolites were found and 11 metabolites including 2-aminoadipic acid, saccharopine and GABA were selected as potential biomarkers of OA progression and OA treatment. This study illustrates that CIL LC-MS is a very useful technique for monitoring incremental metabolomic changes with high coverage and accuracy for studying disease progression and treatment in animal models.

  14. Chemical Isotope Labeling LC-MS for Monitoring Disease Progression and Treatment in Animal Models: Plasma Metabolomics Study of Osteoarthritis Rat Model

    PubMed Central

    Chen, Deying; Su, Xiaoling; Wang, Nan; Li, Yunong; Yin, Hua; Li, Liang; Li, Lanjuan

    2017-01-01

    We report a chemical isotope labeling (CIL) liquid chromatography mass spectrometry (LC-MS) method generally applicable for tracking metabolomic changes from samples collected in an animal model for studying disease development and treatment. A rat model of surgically induced osteoarthritis (OA) was used as an example to illustrate the workflow and technical performance. Experimental duplicate analyses of 234 plasma samples were carried out using dansylation labeling LC-MS targeting the amine/phenol submetabolome. These samples composed of 39 groups (6 rats per group) were collected at multiple time points with sham operation, OA control group, and OA rats with treatment, separately, using glucosamine/Celecoxib and three traditional Chinese medicines (Epimedii folium, Chuanxiong Rhizoma and Bushen-Huoxue). In total, 3893 metabolites could be detected and 2923 of them were consistently detected in more than 50% of the runs. This high-coverage submetabolome dataset could be used to track OA progression and treatment. Many differentiating metabolites were found and 11 metabolites including 2-aminoadipic acid, saccharopine and GABA were selected as potential biomarkers of OA progression and OA treatment. This study illustrates that CIL LC-MS is a very useful technique for monitoring incremental metabolomic changes with high coverage and accuracy for studying disease progression and treatment in animal models. PMID:28091618

  15. Processing methods for differential analysis of LC/MS profile data

    PubMed Central

    Katajamaa, Mikko; Orešič, Matej

    2005-01-01

    Background Liquid chromatography coupled to mass spectrometry (LC/MS) has been widely used in proteomics and metabolomics research. In this context, the technology has been increasingly used for differential profiling, i.e. broad screening of biomolecular components across multiple samples in order to elucidate the observed phenotypes and discover biomarkers. One of the major challenges in this domain remains development of better solutions for processing of LC/MS data. Results We present a software package MZmine that enables differential LC/MS analysis of metabolomics data. This software is a toolbox containing methods for all data processing stages preceding differential analysis: spectral filtering, peak detection, alignment and normalization. Specifically, we developed and implemented a new recursive peak search algorithm and a secondary peak picking method for improving already aligned results, as well as a normalization tool that uses multiple internal standards. Visualization tools enable comparative viewing of data across multiple samples. Peak lists can be exported into other data analysis programs. The toolbox has already been utilized in a wide range of applications. We demonstrate its utility on an example of metabolic profiling of Catharanthus roseus cell cultures. Conclusion The software is freely available under the GNU General Public License and it can be obtained from the project web page at: . PMID:16026613

  16. Processing methods for differential analysis of LC/MS profile data.

    PubMed

    Katajamaa, Mikko; Oresic, Matej

    2005-07-18

    Liquid chromatography coupled to mass spectrometry (LC/MS) has been widely used in proteomics and metabolomics research. In this context, the technology has been increasingly used for differential profiling, i.e. broad screening of biomolecular components across multiple samples in order to elucidate the observed phenotypes and discover biomarkers. One of the major challenges in this domain remains development of better solutions for processing of LC/MS data. We present a software package MZmine that enables differential LC/MS analysis of metabolomics data. This software is a toolbox containing methods for all data processing stages preceding differential analysis: spectral filtering, peak detection, alignment and normalization. Specifically, we developed and implemented a new recursive peak search algorithm and a secondary peak picking method for improving already aligned results, as well as a normalization tool that uses multiple internal standards. Visualization tools enable comparative viewing of data across multiple samples. Peak lists can be exported into other data analysis programs. The toolbox has already been utilized in a wide range of applications. We demonstrate its utility on an example of metabolic profiling of Catharanthus roseus cell cultures. The software is freely available under the GNU General Public License and it can be obtained from the project web page at: http://mzmine.sourceforge.net/.

  17. GeLC-MS-based proteomics of Chromobacterium violaceum: comparison of proteome changes elicited by hydrogen peroxide

    PubMed Central

    Lima, D. C.; Duarte, F. T.; Medeiros, V. K. S.; Carvalho, P. C.; Nogueira, F. C. S.; Araujo, G. D. T.; Domont, G. B.; Batistuzzo de Medeiros, S. R.

    2016-01-01

    Chromobacterium violaceum is a free-living bacillus with several genes that enables it survival under different harsh environments such as oxidative and temperature stresses. Here we performed a label-free quantitative proteomic study to unravel the molecular mechanisms that enable C. violaceum to survive oxidative stress. To achieve this, total proteins extracted from control and C. violaceum cultures exposed during two hours with 8 mM hydrogen peroxide were analyzed using GeLC-MS proteomics. Analysis revealed that under the stress condition, the bacterium expressed proteins that protected it from the damage caused by reactive oxygen condition and decreasing the abundance of proteins responsible for bacterial growth and catabolism. GeLC-MS proteomics analysis provided an overview of the metabolic pathways involved in the response of C. violaceum to oxidative stress ultimately aggregating knowledge of the response of this organism to environmental stress. This study identified approximately 1500 proteins, generating the largest proteomic coverage of C. violaceum so far. We also detected proteins with unknown function that we hypothesize to be part of new mechanisms related to oxidative stress defense. Finally, we identified the mechanism of clustered regularly interspaced short palindromic repeats (CRISPR), which has not yet been reported for this organism. PMID:27321545

  18. GeLC-MS-based proteomics of Chromobacterium violaceum: comparison of proteome changes elicited by hydrogen peroxide.

    PubMed

    Lima, D C; Duarte, F T; Medeiros, V K S; Carvalho, P C; Nogueira, F C S; Araujo, G D T; Domont, G B; Batistuzzo de Medeiros, S R

    2016-06-20

    Chromobacterium violaceum is a free-living bacillus with several genes that enables it survival under different harsh environments such as oxidative and temperature stresses. Here we performed a label-free quantitative proteomic study to unravel the molecular mechanisms that enable C. violaceum to survive oxidative stress. To achieve this, total proteins extracted from control and C. violaceum cultures exposed during two hours with 8 mM hydrogen peroxide were analyzed using GeLC-MS proteomics. Analysis revealed that under the stress condition, the bacterium expressed proteins that protected it from the damage caused by reactive oxygen condition and decreasing the abundance of proteins responsible for bacterial growth and catabolism. GeLC-MS proteomics analysis provided an overview of the metabolic pathways involved in the response of C. violaceum to oxidative stress ultimately aggregating knowledge of the response of this organism to environmental stress. This study identified approximately 1500 proteins, generating the largest proteomic coverage of C. violaceum so far. We also detected proteins with unknown function that we hypothesize to be part of new mechanisms related to oxidative stress defense. Finally, we identified the mechanism of clustered regularly interspaced short palindromic repeats (CRISPR), which has not yet been reported for this organism.

  19. Reagent for Evaluating Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Performance in Bottom-Up Proteomic Experiments.

    PubMed

    Beri, Joshua; Rosenblatt, Michael M; Strauss, Ethan; Urh, Marjeta; Bereman, Michael S

    2015-12-01

    We present a novel proteomic standard for assessing liquid chromatography-tandem mass spectrometry (LC-MS/MS) instrument performance, in terms of chromatographic reproducibility and dynamic range within a single LC-MS/MS injection. The peptide mixture standard consists of six peptides that were specifically synthesized to cover a wide range of hydrophobicities (grand average hydropathy (GRAVY) scores of -0.6 to 1.9). A combination of stable isotope labeled amino acids ((13)C and (15)N) were inserted to create five isotopologues. By combining these isotopologues at different ratios, they span four orders of magnitude within each distinct peptide sequence. Each peptide, from lightest to heaviest, increases in abundance by a factor of 10. We evaluate several metrics on our quadrupole orbitrap instrument using the 6 × 5 LC-MS/MS reference mixture spiked into a complex lysate background as a function of dynamic range, including mass measurement accuracy (MMA) and the linear range of quantitation of MS1 and parallel reaction monitoring experiments. Detection and linearity of the instrument routinely spanned three orders of magnitude across the gradient (500 fmol to 0.5 fmol on column) and no systematic trend was observed for MMA of targeted peptides as a function of abundance by analysis of variance analysis (p = 0.17). Detection and linearity of the fifth isotopologue (i.e., 0.05 fmol on column) was dependent on the peptide and instrument scan type (MS1 vs PRM). We foresee that this standard will serve as a powerful method to conduct both intra-instrument performance monitoring/evaluation, technology development, and inter-instrument comparisons.

  20. Glycoproteins Enrichment and LC-MS/MS Glycoproteomics in Central Nervous System Applications.

    PubMed

    Zhu, Rui; Song, Ehwang; Hussein, Ahmed; Kobeissy, Firas H; Mechref, Yehia

    2017-01-01

    Proteins and glycoproteins play important biological roles in central nervous systems (CNS). Qualitative and quantitative evaluation of proteins and glycoproteins expression in CNS is critical to reveal the inherent biomolecular mechanism of CNS diseases. This chapter describes proteomic and glycoproteomic approaches based on liquid chromatography/tandem mass spectrometry (LC-MS or LC-MS/MS) for the qualitative and quantitative assessment of proteins and glycoproteins expressed in CNS. Proteins and glycoproteins, extracted by a mass spectrometry friendly surfactant from CNS samples, were subjected to enzymatic (tryptic) digestion and three down-stream analyses: (1) a nano LC system coupled with a high-resolution MS instrument to achieve qualitative proteomic profile, (2) a nano LC system combined with a triple quadrupole MS to quantify identified proteins, and (3) glycoprotein enrichment prior to LC-MS/MS analysis. Enrichment techniques can be applied to improve coverage of low abundant glycopeptides/glycoproteins. An example described in this chapter is hydrophilic interaction liquid chromatographic (HILIC) enrichment to capture glycopeptides, allowing efficient removal of peptides. The combination of three LC-MS/MS-based approaches is capable of the investigation of large-scale proteins and glycoproteins from CNS with an in-depth coverage, thus offering a full view of proteins and glycoproteins changes in CNS.

  1. Multiple reaction monitoring targeted LC-MS analysis of potential cell death marker proteins for increased bioprocess control.

    PubMed

    Albrecht, Simone; Kaisermayer, Christian; Reinhart, David; Ambrose, Monica; Kunert, Renate; Lindeberg, Anna; Bones, Jonathan

    2018-05-01

    The monitoring of protein biomarkers for the early prediction of cell stress and death is a valuable tool for process characterization and efficient biomanufacturing control. A representative set of six proteins, namely GPDH, PRDX1, LGALS1, CFL1, TAGLN2 and MDH, which were identified in a previous CHO-K1 cell death model using discovery LC-MS E was translated into a targeted liquid chromatography multiple reaction monitoring mass spectrometry (LC-MRM-MS) platform and verified. The universality of the markers was confirmed in a cell growth model for which three Chinese hamster ovary host cell lines (CHO-K1, CHO-S, CHO-DG44) were grown in batch culture in two different types of basal media. LC-MRM-MS was also applied to spent media (n = 39) from four perfusion biomanufacturing series. Stable isotope-labelled peptide analogues and a stable isotope-labelled monoclonal antibody were used for improved protein quantitation and simultaneous monitoring of the workflow reproducibility. Significant increases in protein concentrations were observed for all viability marker proteins upon increased dead cell numbers and allowed for discrimination of spent media with dead cell densities below and above 1 × 10 6  dead cells/mL which highlights the potential of the selected viability marker proteins in bioprocess control. Graphical abstract Overview of the LC-MRM-MS workflow for the determination of proteomic markers in conditioned media from the bioreactor that correlate with CHO cell death.

  2. Analysis of acrylamide by LC-MS/MS and GC-MS in processed Japanese foods.

    PubMed

    Ono, H; Chuda, Y; Ohnishi-Kameyama, M; Yada, H; Ishizaka, M; Kobayashi, H; Yoshida, M

    2003-03-01

    Acrylamide concentrations in processed foods (63 samples covering 31 product types) from Japan were analysed by LC-MS/MS and GC-MS methods. The limit of detection and limit of quantification of acrylamide were 0.2 ng x ml(-1) (6 fmol) and 0.8 ng x ml(-1) (22 fmol), respectively, by LC-MS/MS, and those of 2,3-dibromopropionamide derived from acrylamide were 12 ng x ml(-1) (52 fmol) and 40 ng x ml(-1) (170 fmol), respectively, by GC-MS. Repeatability given as RSD was <5 and <15% for the LC-MS/MS and GC-MS methods, respectively. High correlation (r(2) - 0.946) was observed between values obtained by the two methods. Most potato crisps and whole potato-based fried snacks showed acrylamide concentrations >1000 microg x kg(-1). The concentrations in non-whole potato-based snacks, rice crackers processed by grilling or frying, and candied sweet potatoes were lower compared with those in the potato crisps and the whole potato-based fried snacks. One of the whole potato-based fried snacks, however, showed low acrylamide concentration (<50 microg x kg(-1)) suggesting the formation of acrylamide is strongly influenced by processing conditions. Acrylamide concentrations in instant precooked noodles and won-tons were <100 microg x kg(-1) with only one exception. Roasted barley grains for 'Mugi-cha' tea contained 200-600 microg x kg(-1) acrylamide.

  3. LC-MS metabolic profiling of Arabidopsis thaliana plant leaves and cell cultures: optimization of pre-LC-MS procedure parameters.

    PubMed

    t'Kindt, Ruben; De Veylder, Lieven; Storme, Michael; Deforce, Dieter; Van Bocxlaer, Jan

    2008-08-01

    This study treats the optimization of methods for homogenizing Arabidopsis thaliana plant leaves as well as cell cultures, and extracting their metabolites for metabolomics analysis by conventional liquid chromatography electrospray ionization mass spectrometry (LC-ESI/MS). Absolute recovery, process efficiency and procedure repeatability have been compared between different pre-LC-MS homogenization/extraction procedures through the use of samples fortified before extraction with a range of representative metabolites. Hereby, the magnitude of the matrix effect observed in the ensuing LC-MS based metabolomics analysis was evaluated. Based on relative recovery and repeatability of key metabolites, comprehensiveness of extraction (number of m/z-retention time pairs) and clean-up potential of the approach (minimum matrix effects), the most appropriate sample pre-treatment was adopted. It combines liquid nitrogen homogenization for plant leaves with thermomixer based extraction using MeOH/H(2)O 80/20. As such, an efficient and highly reproducible LC-MS plant metabolomics set-up is achieved, as illustrated by the obtained results for both LC-MS (8.88%+/-5.16 versus 7.05%+/-4.45) and technical variability (12.53%+/-11.21 versus 9.31%+/-6.65) data in a comparative investigation of A. thaliana plant leaves and cell cultures, respectively.

  4. [LC-MS/MS analysis of determination of strychnine and brucine in formaldehyde fixed tissue].

    PubMed

    Zhan, Lan-fen; Liu, Ming-dong; Yan, You-yi; Ye, Yi; Wang, Wei; Wang, Zhi-hui; Zhao, Jun-hong; Liao, Lin-chuan

    2012-10-01

    To establish a method for determination of strychnine and brucine in formaldehyde fixed tissue by LC-MS/MS analysis. The samples were pretreated with solid phase extraction using SCX cartridges and separated on SB-C18 column with mobile phase 0.1% formic acid : 0.1% formic acid-acetonitrile (75:25). Electrospray ionization (ESI) source was utilized and operated in positive ion mode. Multiple reactions monitoring (MRM) mode was applied. External standard method was applied for quantitation. The chromatographic separation of strychnine and brucine in formaldehyde fixed nephritic and hepatic tissues resulted successfully. The standard curve was linear in the range of 0.002-2.0 microg/g for strychnine and brucine in formaldehyde fixed tissues, and the correlation coefficient was more than 0.996. The limits of detection (LOD) of strychnine and brucine in nephritic tissues were 0.06ng/g and 0.03 ng/g, respectively. The LOD of both chemicals were 0.3 ng/g in hepatic tissues. The extraction recovery rate was more than 74.5%. The precision of intra-day and inter-day were both less than 8.2%. Strychnine and brucine can be sensitive to be determined in formaldehyde fixed tissue by LC-MS/MS analysis. It can be applied in the forensic toxicological analysis.

  5. Analysis of the constituents in jojoba wax used as a food additive by LC/MS/MS.

    PubMed

    Tada, Atsuko; Jin, Zhe-Long; Sugimoto, Naoki; Sato, Kyoko; Yamazaki, Takeshi; Tanamoto, Kenichi

    2005-10-01

    Jojoba wax is a natural gum base used as a food additive in Japan, and is obtained from jojoba oil with a characteristically high melting point. Although the constituents of jojoba oil have been reported, the quality of jojoba wax used as a food additive has not yet been clarified. In order to evaluate its quality as a food additive and to obtain basic information useful for setting official standards, we investigated the constituents and their concentrations in jojoba wax. LC/MS analysis of the jojoba wax showed six peaks with [M+H]+ ions in the range from m/z 533.6 to 673.7 at intervals of m/z 28. After isolation of the components of the four main peaks by preparative LC/MS, the fatty acid and long chain alcohol moieties of the wax esters were analyzed by methanolysis and hydrolysis, followed by GC/MS. The results indicated that the main constituents in jojoba wax were various kinds of wax esters, namely eicosenyl octadecenoate (C20:1-C18:1) (1), eicosenyl eicosenoate (C20:1-C20:1) (II), docosenyl eicosenoate (C22:1-C20:1) (III), eicosenyl docosenoate (C20:1-C22:1) (IV) and tetracosenyl eiosenoate (C24:1-C20:1) (V). To confirm and quantify the wax esters in jojoba wax directly, LC/MS/MS analysis was performed. The product ions corresponding to the fatty acid moieties of the wax esters were observed, and by using the product ions derived from the protonated molecular ions of wax esters the fatty acid moieties were identified by MRM analysis. The concentrations of the wax esters I, II and III, in jojoba wax were 5.5, 21.4 and 37.8%, respectively. In summary, we clarified the main constituents of jojoba wax and quantified the molecular species of the wax esters without hydrolysis by monitoring their product ions, using a LC/MS/MS system.

  6. Data Treatment for LC-MS Untargeted Analysis.

    PubMed

    Riccadonna, Samantha; Franceschi, Pietro

    2018-01-01

    Liquid chromatography-mass spectrometry (LC-MS) untargeted experiments require complex chemometrics strategies to extract information from the experimental data. Here we discuss "data preprocessing", the set of procedures performed on the raw data to produce a data matrix which will be the starting point for the subsequent statistical analysis. Data preprocessing is a crucial step on the path to knowledge extraction, which should be carefully controlled and optimized in order to maximize the output of any untargeted metabolomics investigation.

  7. Advancing a High Throughput Glycotope-centric Glycomics Workflow Based on nanoLC-MS2-product Dependent-MS3 Analysis of Permethylated Glycans.

    PubMed

    Hsiao, Cheng-Te; Wang, Po-Wei; Chang, Hua-Chien; Chen, Yen-Ying; Wang, Shui-Hua; Chern, Yijuang; Khoo, Kay-Hooi

    2017-12-01

    The intrinsic nature of glycosylation, namely nontemplate encoded, stepwise elongation and termination with a diverse range of isomeric glyco-epitopes (glycotopes), translates into ambiguity in most cases of mass spectrometry (MS)-based glycomic mapping. It is arguable that whether one needs to delineate every single glycomic entity, which may be counterproductive. Instead, one should focus on identifying as many structural features as possible that would collectively define the glycomic characteristics of a cell or tissue, and how these may change in response to self-programmed development, immuno-activation, and malignant transformation. We have been pursuing this line of analytical strategy that homes in on identifying the terminal sulfo-, sialyl, and/or fucosylated glycotopes by comprehensive nanoLC-MS 2 -product dependent MS 3 analysis of permethylated glycans, in conjunction with development of a data mining computational tool, GlyPick, to enable an automated, high throughput, semi-quantitative glycotope-centric glycomic mapping amenable to even nonexperts. We demonstrate in this work that diagnostic MS 2 ions can be relied on to inform the presence of specific glycotopes, whereas their possible isomeric identities can be resolved at MS 3 level. Both MS 2 and associated MS 3 data can be acquired exhaustively and processed automatically by GlyPick. The high acquisition speed, resolution, and mass accuracy afforded by top-notch Orbitrap Fusion MS system now allow a sensible spectral count and/or summed ion intensity-based glycome-wide glycotope quantification. We report here the technical aspects, reproducibility and optimization of such an analytical approach that uses the same acidic reverse phase C18 nanoLC conditions fully compatible with proteomic analysis to allow rapid hassle-free switching. We further show how this workflow is particularly effective when applied to larger, multiply sialylated and fucosylated N-glycans derived from mouse brain. The

  8. TransOmic analysis of forebrain sections in Sp2 conditional knockout embryonic mice using IR-MALDESI imaging of lipids and LC-MS/MS label-free proteomics

    PubMed Central

    Loziuk, Philip; Meier, Florian; Johnson, Caroline

    2016-01-01

    Quantitative methods for detection of biological molecules are needed more than ever before in the emerging age of “omics” and “big data.” Here, we provide an integrated approach for systematic analysis of the “lipidome” in tissue. To test our approach in a biological context, we utilized brain tissue selectively deficient for the transcription factor Specificity Protein 2 (Sp2). Conditional deletion of Sp2 in the mouse cerebral cortex results in developmental deficiencies including disruption of lipid metabolism. Silver (Ag) cationization was implemented for infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) to enhance the ion abundances for olefinic lipids, as these have been linked to regulation by Sp2. Combining Ag-doped and conventional IR-MALDESI imaging, this approach was extended to IR-MALDESI imaging of embryonic mouse brains. Further, our imaging technique was combined with bottom-up shotgun proteomic LC-MS/MS analysis and western blot for comparing Sp2 conditional knockout (Sp2-cKO) and wild-type (WT) cortices of tissue sections. This provided an integrated omics dataset which revealed many specific changes to fundamental cellular processes and biosynthetic pathways. In particular, step-specific altered abundances of nucleotides, lipids, and associated proteins were observed in the cerebral cortices of Sp2-cKO embryos. PMID:26942738

  9. Quantitation of Tenofovir and Emtricitabine in Dried Blood Spots (DBS) with LC-MS/MS

    PubMed Central

    Zheng, Jia-Hua; Guida, Louis A; Rower, Caitlin; Castillo-Mancilla, Jose; Meditz, Amie; Klein, Brandon; Kerr, Becky Jo; Langness, Jacob; Bushman, Lane; Kiser, Jennifer; Anderson, Peter L.

    2013-01-01

    A reversed-phase high performance liquid chromatographic (LC), tandem mass spectrometry (MS/MS) assay for the determination of tenofovir (TFV) and emtricitabine (FTC) in dried blood spots (DBS) from human whole blood was developed and validated. Whole blood samples were spotted, dried, and a 3mm punch was extracted with methanol for analysis by LC-MS/MS utilizing stable isotope labeled internal standards. The assay was validated over the range of 2.5ng/mL to 1,000ng/mL for TFV and 2.5ng/mL to 5,000ng/mL for FTC. The method was accurate (within ± 15% of control) and precise (coefficient of variation ≤ 15%) for hematocrit concentrations ranging from 25% to 76%; using edge punches versus center punches; and spot volumes of 10µL to 50µL. Analytes were stable for five freeze/thaw cycles and up to 6 days at room temperature, whereas long-term storage required −20°C or −80°C. Comparison of TFV and FTC in DBS versus plasma yielded r2 ≥ 0.96, indicating that DBS can be used as a plasma alternative for pharmacokinetic analyses in vivo. PMID:24055850

  10. Proteomic analysis of formalin-fixed paraffin-embedded renal tissue samples by label-free MS: assessment of overall technical variability and the impact of block age.

    PubMed

    Craven, Rachel A; Cairns, David A; Zougman, Alexandre; Harnden, Patricia; Selby, Peter J; Banks, Rosamonde E

    2013-04-01

    Protein profiling of formalin-fixed paraffin-embedded (FFPE) tissues has enormous potential for the discovery and validation of disease biomarkers. The aim of this study was to systematically characterize the effect of length of time of storage of such tissue blocks in pathology archives on the quality of data produced using label-free MS. Normal kidney and clear cell renal cell carcinoma tissues routinely collected up to 10 years prior to analysis were profiled using LC-MS/MS and the data analyzed using MaxQuant. Protein identities and quantification data were analyzed to examine differences between tissue blocks of different ages and assess the impact of technical and biological variability. An average of over 2000 proteins was seen in each sample with good reproducibility in terms of proteins identified and quantification for normal kidney tissue, with no significant effect of block age. Greater biological variability was apparent in the renal cell carcinoma tissue, possibly reflecting disease heterogeneity, but again there was good correlation between technical replicates and no significant effect of block age. These results indicate that archival storage time does not have a detrimental effect on protein profiling of FFPE tissues, supporting the use of such tissues in biomarker discovery studies. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Design and analysis of quantitative differential proteomics investigations using LC-MS technology.

    PubMed

    Bukhman, Yury V; Dharsee, Moyez; Ewing, Rob; Chu, Peter; Topaloglou, Thodoros; Le Bihan, Thierry; Goh, Theo; Duewel, Henry; Stewart, Ian I; Wisniewski, Jacek R; Ng, Nancy F

    2008-02-01

    Liquid chromatography-mass spectrometry (LC-MS)-based proteomics is becoming an increasingly important tool in characterizing the abundance of proteins in biological samples of various types and across conditions. Effects of disease or drug treatments on protein abundance are of particular interest for the characterization of biological processes and the identification of biomarkers. Although state-of-the-art instrumentation is available to make high-quality measurements and commercially available software is available to process the data, the complexity of the technology and data presents challenges for bioinformaticians and statisticians. Here, we describe a pipeline for the analysis of quantitative LC-MS data. Key components of this pipeline include experimental design (sample pooling, blocking, and randomization) as well as deconvolution and alignment of mass chromatograms to generate a matrix of molecular abundance profiles. An important challenge in LC-MS-based quantitation is to be able to accurately identify and assign abundance measurements to members of protein families. To address this issue, we implement a novel statistical method for inferring the relative abundance of related members of protein families from tryptic peptide intensities. This pipeline has been used to analyze quantitative LC-MS data from multiple biomarker discovery projects. We illustrate our pipeline here with examples from two of these studies, and show that the pipeline constitutes a complete workable framework for LC-MS-based differential quantitation. Supplementary material is available at http://iec01.mie.utoronto.ca/~thodoros/Bukhman/.

  12. The Use of Ammonium Formate as a Mobile-Phase Modifier for LC-MS/MS Analysis of Tryptic Digests

    PubMed Central

    Johnson, Darryl; Boyes, Barry; Orlando, Ron

    2013-01-01

    A major challenge facing current mass spectrometry (MS)-based proteomics research is the large concentration range displayed in biological systems, which far exceeds the dynamic range of commonly available mass spectrometers. One approach to overcome this limitation is to improve online reversed-phase liquid chromatography (RP-LC) separation methodologies. LC mobile-phase modifiers are used to improve peak shape and increase sample load tolerance. Trifluoroacetic acid (TFA) is a commonly used mobile-phase modifier, as it produces peptide separations that are far superior to other additives. However, TFA leads to signal suppression when incorporated with electrospray ionization (ESI), and thus, other modifiers, such as formic acid (FA), are used for LC-MS applications. FA exhibits significantly less signal suppression, but is not as effective of a modifier as TFA. An alternative mobile-phase modifier is the combination of FA and ammonium formate (AF), which has been shown to improve peptide separations. The ESI-MS compatibility of this modifier has not been investigated, particularly for proteomic applications. This work compares the separation metrics of mobile phases modified with FA and FA/AF and explores the use of FA/AF for the LC-MS analysis of tryptic digests. Standard tryptic-digest peptides were used for comparative analysis of peak capacity and sample load tolerance. The compatibility of FA/AF in proteomic applications was examined with the analysis of soluble proteins from canine prostate carcinoma tissue. Overall, the use of FA/AF improved online RP-LC separations and led to significant increases in peptide identifications with improved protein sequence coverage. PMID:24294112

  13. The use of ammonium formate as a mobile-phase modifier for LC-MS/MS analysis of tryptic digests.

    PubMed

    Johnson, Darryl; Boyes, Barry; Orlando, Ron

    2013-12-01

    A major challenge facing current mass spectrometry (MS)-based proteomics research is the large concentration range displayed in biological systems, which far exceeds the dynamic range of commonly available mass spectrometers. One approach to overcome this limitation is to improve online reversed-phase liquid chromatography (RP-LC) separation methodologies. LC mobile-phase modifiers are used to improve peak shape and increase sample load tolerance. Trifluoroacetic acid (TFA) is a commonly used mobile-phase modifier, as it produces peptide separations that are far superior to other additives. However, TFA leads to signal suppression when incorporated with electrospray ionization (ESI), and thus, other modifiers, such as formic acid (FA), are used for LC-MS applications. FA exhibits significantly less signal suppression, but is not as effective of a modifier as TFA. An alternative mobile-phase modifier is the combination of FA and ammonium formate (AF), which has been shown to improve peptide separations. The ESI-MS compatibility of this modifier has not been investigated, particularly for proteomic applications. This work compares the separation metrics of mobile phases modified with FA and FA/AF and explores the use of FA/AF for the LC-MS analysis of tryptic digests. Standard tryptic-digest peptides were used for comparative analysis of peak capacity and sample load tolerance. The compatibility of FA/AF in proteomic applications was examined with the analysis of soluble proteins from canine prostate carcinoma tissue. Overall, the use of FA/AF improved online RP-LC separations and led to significant increases in peptide identifications with improved protein sequence coverage.

  14. Application of survival analysis methodology to the quantitative analysis of LC-MS proteomics data.

    PubMed

    Tekwe, Carmen D; Carroll, Raymond J; Dabney, Alan R

    2012-08-01

    Protein abundance in quantitative proteomics is often based on observed spectral features derived from liquid chromatography mass spectrometry (LC-MS) or LC-MS/MS experiments. Peak intensities are largely non-normal in distribution. Furthermore, LC-MS-based proteomics data frequently have large proportions of missing peak intensities due to censoring mechanisms on low-abundance spectral features. Recognizing that the observed peak intensities detected with the LC-MS method are all positive, skewed and often left-censored, we propose using survival methodology to carry out differential expression analysis of proteins. Various standard statistical techniques including non-parametric tests such as the Kolmogorov-Smirnov and Wilcoxon-Mann-Whitney rank sum tests, and the parametric survival model and accelerated failure time-model with log-normal, log-logistic and Weibull distributions were used to detect any differentially expressed proteins. The statistical operating characteristics of each method are explored using both real and simulated datasets. Survival methods generally have greater statistical power than standard differential expression methods when the proportion of missing protein level data is 5% or more. In particular, the AFT models we consider consistently achieve greater statistical power than standard testing procedures, with the discrepancy widening with increasing missingness in the proportions. The testing procedures discussed in this article can all be performed using readily available software such as R. The R codes are provided as supplemental materials. ctekwe@stat.tamu.edu.

  15. LC-MS/MS imaging with thermal film-based laser microdissection.

    PubMed

    Oya, Michiko; Suzuki, Hiromi; Anas, Andrea Roxanne J; Oishi, Koichi; Ono, Kenji; Yamaguchi, Shun; Eguchi, Megumi; Sawada, Makoto

    2018-01-01

    Mass spectrometry (MS) imaging is a useful tool for direct and simultaneous visualization of specific molecules. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is used to evaluate the abundance of molecules in tissues using sample homogenates. To date, however, LC-MS/MS has not been utilized as an imaging tool because spatial information is lost during sample preparation. Here we report a new approach for LC-MS/MS imaging using a thermal film-based laser microdissection (LMD) technique. To isolate tissue spots, our LMD system uses a 808-nm near infrared laser, the diameter of which can be freely changed from 2.7 to 500 μm; for imaging purposes in this study, the diameter was fixed at 40 μm, allowing acquisition of LC-MS/MS images at a 40-μm resolution. The isolated spots are arranged on a thermal film at 4.5-mm intervals, corresponding to the well spacing on a 384-well plate. Each tissue spot is handled on the film in such a manner as to maintain its spatial information, allowing it to be extracted separately in its individual well. Using analytical LC-MS/MS in combination with the spatial information of each sample, we can reconstruct LC-MS/MS images. With this imaging technique, we successfully obtained the distributions of pilocarpine, glutamate, γ-aminobutyric acid, acetylcholine, and choline in a cross-section of mouse hippocampus. The protocol we established in this study is applicable to revealing the neurochemistry of pilocarpine model of epilepsy. Our system has a wide range of uses in fields such as biology, pharmacology, pathology, and neuroscience. Graphical abstract Schematic Indication of LMD-LC-MS/MS imaging.

  16. Characteristic fingerprinting based on macamides for discrimination of maca (Lepidium meyenii) by LC/MS/MS and multivariate statistical analysis.

    PubMed

    Pan, Yu; Zhang, Ji; Li, Hong; Wang, Yuan-Zhong; Li, Wan-Yi

    2016-10-01

    Macamides with a benzylalkylamide nucleus are characteristic and major bioactive compounds in the functional food maca (Lepidium meyenii Walp). The aim of this study was to explore variations in macamide content among maca from China and Peru. Twenty-seven batches of maca hypocotyls with different phenotypes, sampled from different geographical origins, were extracted and profiled by liquid chromatography with ultraviolet detection/tandem mass spectrometry (LC-UV/MS/MS). Twelve macamides were identified by MS operated in multiple scanning modes. Similarity analysis showed that maca samples differed significantly in their macamide fingerprinting. Partial least squares discriminant analysis (PLS-DA) was used to differentiate samples according to their geographical origin and to identify the most relevant variables in the classification model. The prediction accuracy for raw maca was 91% and five macamides were selected and considered as chemical markers for sample classification. When combined with a PLS-DA model, characteristic fingerprinting based on macamides could be recommended for labelling for the authentication of maca from different geographical origins. The results provided potential evidence for the relationships between environmental or other factors and distribution of macamides. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  17. Isotope Inversion Experiment evaluating the suitability of calibration in surrogate matrix for quantification via LC-MS/MS-Exemplary application for a steroid multi-method.

    PubMed

    Suhr, Anna Catharina; Vogeser, Michael; Grimm, Stefanie H

    2016-05-30

    For quotable quantitative analysis of endogenous analytes in complex biological samples by isotope dilution LC-MS/MS, the creation of appropriate calibrators is a challenge, since analyte-free authentic material is in general not available. Thus, surrogate matrices are often used to prepare calibrators and controls. However, currently employed validation protocols do not include specific experiments to verify the suitability of a surrogate matrix calibration for quantification of authentic matrix samples. The aim of the study was the development of a novel validation experiment to test whether surrogate matrix based calibrators enable correct quantification of authentic matrix samples. The key element of the novel validation experiment is the inversion of nonlabelled analytes and their stable isotope labelled (SIL) counterparts in respect to their functions, i.e. SIL compound is the analyte and nonlabelled substance is employed as internal standard. As a consequence, both surrogate and authentic matrix are analyte-free regarding SIL analytes, which allows a comparison of both matrices. We called this approach Isotope Inversion Experiment. As figure of merit we defined the accuracy of inverse quality controls in authentic matrix quantified by means of a surrogate matrix calibration curve. As a proof-of-concept application a LC-MS/MS assay addressing six corticosteroids (cortisol, cortisone, corticosterone, 11-deoxycortisol, 11-deoxycorticosterone, and 17-OH-progesterone) was chosen. The integration of the Isotope Inversion Experiment in the validation protocol for the steroid assay was successfully realized. The accuracy results of the inverse quality controls were all in all very satisfying. As a consequence the suitability of a surrogate matrix calibration for quantification of the targeted steroids in human serum as authentic matrix could be successfully demonstrated. The Isotope Inversion Experiment fills a gap in the validation process for LC-MS/MS assays

  18. LC-MS analysis of glycoalkaloid diversity among seven potato genotypes

    USDA-ARS?s Scientific Manuscript database

    Secondary metabolites in potato tubers include both phytonutrients and plant defense compounds. The extent of variation in these small molecules among different potato genotypes is not well characterized. LC-MS analysis of tuber extracts from seven potato genotypes showed that one large source of sm...

  19. Quantitative Proteomics Analysis of VEGF-Responsive Endothelial Protein S-Nitrosylation Using Stable Isotope Labeling by Amino Acids in Cell Culture (SILAC) and LC-MS/MS.

    PubMed

    Zhang, Hong-Hai; Lechuga, Thomas J; Chen, Yuezhou; Yang, Yingying; Huang, Lan; Chen, Dong-Bao

    2016-05-01

    Adduction of a nitric oxide moiety (NO•) to cysteine(s), termed S-nitrosylation (SNO), is a novel mechanism for NO to regulate protein function directly. However, the endothelial SNO-protein network that is affected by endogenous and exogenous NO is obscure. This study was designed to develop a quantitative proteomics approach using stable isotope labeling by amino acids in cell culture for comparing vascular endothelial growth factor (VEGFA)- and NO donor-responsive endothelial nitroso-proteomes. Primary placental endothelial cells were labeled with "light" (L-(12)C6 (14)N4-Arg and L-(12)C6 (14)N2-Lys) or "heavy" (L-(13)C6 (15)N4-Arg and L-(13)C6 (15)N2-Lys) amino acids. The light cells were treated with an NO donor nitrosoglutathione (GSNO, 1 mM) or VEGFA (10 ng/ml) for 30 min, while the heavy cells received vehicle as control. Equal amounts of cellular proteins from the light (GSNO or VEGFA treated) and heavy cells were mixed for labeling SNO-proteins by the biotin switch technique and then trypsin digested. Biotinylated SNO-peptides were purified for identifying SNO-proteins by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Ratios of light to heavy SNO-peptides were calculated for determining the changes of the VEGFA- and GSNO-responsive endothelial nitroso-proteomes. A total of 387 light/heavy pairs of SNO-peptides were identified, corresponding to 213 SNO-proteins that include 125 common and 27 VEGFA- and 61 GSNO-responsive SNO-proteins. The specific SNO-cysteine(s) in each SNO-protein were simultaneously identified. Pathway analysis revealed that SNO-proteins are involved in various endothelial functions, including proliferation, motility, metabolism, and protein synthesis. We collectively conclude that endogenous NO on VEGFA stimulation and exogenous NO from GSNO affect common and different SNO-protein networks, implicating SNO as a critical mechanism for VEGFA stimulation of angiogenesis. © 2016 by the Society for the Study of Reproduction

  20. Rapid measurement of plasma free fatty acid concentration and isotopic enrichment using LC/MS

    PubMed Central

    Persson, Xuan-Mai T.; Błachnio-Zabielska, Agnieszka Urszula; Jensen, Michael D.

    2010-01-01

    Measurements of plasma free fatty acids (FFA) concentration and isotopic enrichment are commonly used to evaluate FFA metabolism. Until now, gas chromatography-combustion-isotope ratio mass spectrometry (GC/C/IRMS) was the best method to measure isotopic enrichment in the methyl derivatives of 13C-labeled fatty acids. Although IRMS is excellent for analyzing enrichment, it requires time-consuming derivatization steps and is not optimal for measuring FFA concentrations. We developed a new, rapid, and reliable method for simultaneous quantification of 13C-labeled fatty acids in plasma using high-performance liquid chromatography-mass spectrometry (HPLC/MS). This method involves a very quick Dole extraction procedure and direct injection of the samples on the HPLC system. After chromatographic separation, the samples are directed to the mass spectrometer for electrospray ionization (ESI) and analysis in the negative mode using single ion monitoring. By employing equipment with two columns connected parallel to a mass spectrometer, we can double the throughput to the mass spectrometer, reducing the analysis time per sample to 5 min. Palmitate flux measured using this approach agreed well with the GC/C/IRMS method. This HPLC/MS method provides accurate and precise measures of FFA concentration and enrichment. PMID:20526002

  1. Label-Free LC-MS Profiling of Skeletal Muscle Reveals Heart-Type Fatty Acid Binding Protein as a Candidate Biomarker of Aerobic Capacity.

    PubMed

    Malik, Zulezwan Ab; Cobley, James N; Morton, James P; Close, Graeme L; Edwards, Ben J; Koch, Lauren G; Britton, Steven L; Burniston, Jatin G

    2013-12-01

    Two-dimensional gel electrophoresis provides robust comparative analysis of skeletal muscle, but this technique is laborious and limited by its inability to resolve all proteins. In contrast, orthogonal separation by SDS-PAGE and reverse-phase liquid chromatography (RPLC) coupled to mass spectrometry (MS) affords deep mining of the muscle proteome, but differential analysis between samples is challenging due to the greater level of fractionation and the complexities of quantifying proteins based on the abundances of their tryptic peptides. Here we report simple, semi-automated and time efficient ( i.e ., 3 h per sample) proteome profiling of skeletal muscle by 1-dimensional RPLC electrospray ionisation tandem MS. Solei were analysed from rats (n = 5, in each group) bred as either high- or low-capacity runners (HCR and LCR, respectively) that exhibited a 6.4-fold difference (1,625 ± 112 m vs . 252 ± 43 m, p < 0.0001) in running capacity during a standardized treadmill test. Soluble muscle proteins were extracted, digested with trypsin and individual biological replicates (50 ng of tryptic peptides) subjected to LC-MS profiling. Proteins were identified by triplicate LC-MS/MS analysis of a pooled sample of each biological replicate. Differential expression profiling was performed on relative abundances (RA) of parent ions, which spanned three orders of magnitude. In total, 207 proteins were analysed, which encompassed almost all enzymes of the major metabolic pathways in skeletal muscle. The most abundant protein detected was type I myosin heavy chain (RA = 5,843 ± 897) and the least abundant protein detected was heat shock 70 kDa protein (RA = 2 ± 0.5). Sixteen proteins were significantly ( p < 0.05) more abundant in HCR muscle and hierarchal clustering of the profiling data highlighted two protein subgroups, which encompassed proteins associated with either the respiratory chain or fatty acid oxidation. Heart-type fatty acid binding protein (FABPH) was 1

  2. Validation of an LC-MS/MS method for the quantification of choline-related compounds and phospholipids in foods and tissues.

    PubMed

    Xiong, Yeping; Zhao, Yuan-Yuan; Goruk, Sue; Oilund, Kirsten; Field, Catherine J; Jacobs, René L; Curtis, Jonathan M

    2012-12-12

    A hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC LC-MS/MS) method was developed and validated to simultaneously quantify six aqueous choline-related compounds and eight major phospholipids classes in a single run. HILIC chromatography was coupled to positive ion electrospray mass spectrometry. A combination of multiple scan modes including precursor ion scan, neutral loss scan and multiple reaction monitoring was optimized for the determination of each compound or class in a single LC/MS run. This work developed a simplified extraction scheme in which both free choline and related compounds along with phospholipids were extracted into a homogenized phase using chloroform/methanol/water (1:2:0.8) and diluted into methanol for the analysis of target compounds in a variety of sample matrices. The analyte recoveries were evaluated by spiking tissues and food samples with two isotope-labeled internal standards, PC-d(3) and Cho-d(3). Recoveries of between 90% and 115% were obtained by spiking a range of sample matrices with authentic standards containing all 14 of the target analytes. The precision of the analysis ranged from 1.6% to 13%. Accuracy and precision was comparable to that obtained by quantification of selected phospholipid classes using (31)P NMR. A variety of sample matrices including egg yolks, human diets and animal tissues were analyzed using the validated method. The measurements of total choline in selected foods were found to be in good agreement with values obtained from the USDA choline database. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Platform-independent and Label-free Quantitation of Proteomic Data Using MS1 Extracted Ion Chromatograms in Skyline

    PubMed Central

    Schilling, Birgit; Rardin, Matthew J.; MacLean, Brendan X.; Zawadzka, Anna M.; Frewen, Barbara E.; Cusack, Michael P.; Sorensen, Dylan J.; Bereman, Michael S.; Jing, Enxuan; Wu, Christine C.; Verdin, Eric; Kahn, C. Ronald; MacCoss, Michael J.; Gibson, Bradford W.

    2012-01-01

    Despite advances in metabolic and postmetabolic labeling methods for quantitative proteomics, there remains a need for improved label-free approaches. This need is particularly pressing for workflows that incorporate affinity enrichment at the peptide level, where isobaric chemical labels such as isobaric tags for relative and absolute quantitation and tandem mass tags may prove problematic or where stable isotope labeling with amino acids in cell culture labeling cannot be readily applied. Skyline is a freely available, open source software tool for quantitative data processing and proteomic analysis. We expanded the capabilities of Skyline to process ion intensity chromatograms of peptide analytes from full scan mass spectral data (MS1) acquired during HPLC MS/MS proteomic experiments. Moreover, unlike existing programs, Skyline MS1 filtering can be used with mass spectrometers from four major vendors, which allows results to be compared directly across laboratories. The new quantitative and graphical tools now available in Skyline specifically support interrogation of multiple acquisitions for MS1 filtering, including visual inspection of peak picking and both automated and manual integration, key features often lacking in existing software. In addition, Skyline MS1 filtering displays retention time indicators from underlying MS/MS data contained within the spectral library to ensure proper peak selection. The modular structure of Skyline also provides well defined, customizable data reports and thus allows users to directly connect to existing statistical programs for post hoc data analysis. To demonstrate the utility of the MS1 filtering approach, we have carried out experiments on several MS platforms and have specifically examined the performance of this method to quantify two important post-translational modifications: acetylation and phosphorylation, in peptide-centric affinity workflows of increasing complexity using mouse and human models. PMID:22454539

  4. Multi-profile Bayesian alignment model for LC-MS data analysis with integration of internal standards

    PubMed Central

    Tsai, Tsung-Heng; Tadesse, Mahlet G.; Di Poto, Cristina; Pannell, Lewis K.; Mechref, Yehia; Wang, Yue; Ressom, Habtom W.

    2013-01-01

    Motivation: Liquid chromatography-mass spectrometry (LC-MS) has been widely used for profiling expression levels of biomolecules in various ‘-omic’ studies including proteomics, metabolomics and glycomics. Appropriate LC-MS data preprocessing steps are needed to detect true differences between biological groups. Retention time (RT) alignment, which is required to ensure that ion intensity measurements among multiple LC-MS runs are comparable, is one of the most important yet challenging preprocessing steps. Current alignment approaches estimate RT variability using either single chromatograms or detected peaks, but do not simultaneously take into account the complementary information embedded in the entire LC-MS data. Results: We propose a Bayesian alignment model for LC-MS data analysis. The alignment model provides estimates of the RT variability along with uncertainty measures. The model enables integration of multiple sources of information including internal standards and clustered chromatograms in a mathematically rigorous framework. We apply the model to LC-MS metabolomic, proteomic and glycomic data. The performance of the model is evaluated based on ground-truth data, by measuring correlation of variation, RT difference across runs and peak-matching performance. We demonstrate that Bayesian alignment model improves significantly the RT alignment performance through appropriate integration of relevant information. Availability and implementation: MATLAB code, raw and preprocessed LC-MS data are available at http://omics.georgetown.edu/alignLCMS.html Contact: hwr@georgetown.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:24013927

  5. Ranking Fragment Ions Based on Outlier Detection for Improved Label-Free Quantification in Data-Independent Acquisition LC-MS/MS

    PubMed Central

    Bilbao, Aivett; Zhang, Ying; Varesio, Emmanuel; Luban, Jeremy; Strambio-De-Castillia, Caterina; Lisacek, Frédérique; Hopfgartner, Gérard

    2016-01-01

    Data-independent acquisition LC-MS/MS techniques complement supervised methods for peptide quantification. However, due to the wide precursor isolation windows, these techniques are prone to interference at the fragment ion level, which in turn is detrimental for accurate quantification. The “non-outlier fragment ion” (NOFI) ranking algorithm has been developed to assign low priority to fragment ions affected by interference. By using the optimal subset of high priority fragment ions these interfered fragment ions are effectively excluded from quantification. NOFI represents each fragment ion as a vector of four dimensions related to chromatographic and MS fragmentation attributes and applies multivariate outlier detection techniques. Benchmarking conducted on a well-defined quantitative dataset (i.e. the SWATH Gold Standard), indicates that NOFI on average is able to accurately quantify 11-25% more peptides than the commonly used Top-N library intensity ranking method. The sum of the area of the Top3-5 NOFIs produces similar coefficients of variation as compared to the library intensity method but with more accurate quantification results. On a biologically relevant human dendritic cell digest dataset, NOFI properly assigns low priority ranks to 85% of annotated interferences, resulting in sensitivity values between 0.92 and 0.80 against 0.76 for the Spectronaut interference detection algorithm. PMID:26412574

  6. Analytical determination of virginiamycin drug residues in edible porcine tissues by LC-MS with confirmation by LC-MS/MS.

    PubMed

    Boison, Joe; Lee, Stephen; Gedir, Ron

    2009-01-01

    A liquid chromatographic-mass spectrometric (LC-MS) method was developed and validated for the determination and confirmation of virginiamycin (VMY) M1 residues in porcine liver, kidney, and muscle tissues at concentrations > or =2 ng/g. Porcine liver, kidney, or muscle tissue is homogenized with methanol-acetonitrile. After centrifugation, the supernatant is diluted with phosphate buffer and cleaned up on a C18 solid-phase extraction cartridge. VMY in the eluate is partitioned into chloroform and the aqueous upper layer is removed by aspiration. After evaporating the chloroform in the residual mixture to dryness, the dried extract is reconstituted in mobile phase and VMY is quantified by LC-MS. Any samples eliciting quantifiable levels of VMY M1 (i.e., at concentrations > or =2 ng/g) are subjected to confirmatory analysis by LC-MSIMS. VMY S1, a minor component of the VMY complex, is monitored but not quantified or confirmed.

  7. Development of isotope labeling LC-MS for human salivary metabolomics and application to profiling metabolome changes associated with mild cognitive impairment.

    PubMed

    Zheng, Jiamin; Dixon, Roger A; Li, Liang

    2012-12-18

    Saliva is a readily available biofluid that may contain metabolites of interest for diagnosis and prognosis of diseases. In this work, a differential (13)C/(12)C isotope dansylation labeling method, combined with liquid chromatography Fourier transform ion cyclotron resonance mass spectrometry (LC-FTICR-MS), is described for quantitative profiling of the human salivary metabolome. New strategies are presented to optimize the sample preparation and LC-MS detection processes. The strategies allow the use of as little of 5 μL of saliva sample as a starting material to determine the concentration changes of an average of 1058 ion pairs or putative metabolites in comparative saliva samples. The overall workflow consists of several steps including acetone-induced protein precipitation, (12)C-dansylation labeling of the metabolites, and LC-UV measurement of the total concentration of the labeled metabolites in individual saliva samples. A pooled sample was prepared from all the individual samples and labeled with (13)C-dansylation to serve as a reference. Using this metabolome profiling method, it was found that compatible metabolome results could be obtained after saliva samples were stored in tubes normally used for genetic material collection at room temperature, -20 °C freezer, and -80 °C freezer over a period of 1 month, suggesting that many saliva samples already collected in genomic studies could become a valuable resource for metabolomics studies, although the effect of much longer term of storage remains to be determined. Finally, the developed method was applied for analyzing the metabolome changes of two different groups: normal healthy older adults and comparable older adults with mild cognitive impairment (MCI). Top-ranked 18 metabolites successfully distinguished the two groups, among which seven metabolites were putatively identified while one metabolite, taurine, was definitively identified.

  8. A sensitive LC-MS/MS method for measurement of organophosphorus pesticides and their oxygen analogs in air sampling matrices.

    PubMed

    Armstrong, Jenna L; Dills, Russell L; Yu, Jianbo; Yost, Michael G; Fenske, Richard A

    2014-01-01

    A rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed for determination of levels of the organophosphorus (OP) pesticides chlorpyrifos (CPF), azinphos methyl (AZM), and their oxygen analogs chlorpyrifos-oxon (CPF-O) and azinphos methyl-oxon (AZM-O) on common active air sampling matrices. XAD-2 resin and polyurethane foam (PUF) matrices were extracted with acetonitrile containing stable-isotope labeled internal standards (ISTD). Analysis was accomplished in Multiple Reaction Monitoring (MRM) mode, and analytes in unknown samples were identified by retention time (±0.1 min) and qualifier ratio (±30% absolute) as compared to the mean of calibrants. For all compounds, calibration linearity correlation coefficients were ≥0.996. Limits of detection (LOD) ranged from 0.15-1.1 ng/sample for CPF, CPF-O, AZM, and AZM-O on active sampling matrices. Spiked fortification recoveries were 78-113% from XAD-2 active air sampling tubes and 71-108% from PUF active air sampling tubes. Storage stability tests also yielded recoveries ranging from 74-94% after time periods ranging from 2-10 months. The results demonstrate that LC-MS/MS is a sensitive method for determining these compounds from two different matrices at the low concentrations that can result from spray drift and long range transport in non-target areas following agricultural applications. In an inter-laboratory comparison, the limit of quantification (LOQ) for LC-MS/MS was 100 times lower than a typical gas chromatography-mass spectrometry (GC-MS) method.

  9. Absolute quantification of histone PTM marks by MRM-based LC-MS/MS.

    PubMed

    Gao, Jun; Liao, Rijing; Yu, Yanyan; Zhai, Huili; Wang, Yingqi; Sack, Ragna; Peters, Antoine H F M; Chen, Jiajia; Wu, Haiping; Huang, Zheng; Hu, Min; Qi, Wei; Lu, Chris; Atadja, Peter; Oyang, Counde; Li, En; Yi, Wei; Zhou, Shaolian

    2014-10-07

    The N-terminal tails of core histones harbor the sites of numerous post-translational modifications (PTMs) with important roles in the regulation of chromatin structure and function. Profiling histone PTM marks provides data that help understand the epigenetics events in cells and their connections with cancer and other diseases. Our previous study demonstrated that specific derivatization of histone peptides by NHS propionate significantly improved their chromatographic performance on reversed phase columns for LC/MS analysis. As a step forward, we recently developed a multiple reaction monitoring (MRM) based LC-MS/MS method to analyze 42 targeted histone peptides. By using stable isotopic labeled peptides as internal standards that are spiked into the reconstituted solutions, this method allows to measure absolute concentration of the tryptic peptides of H3 histone proteins extracted from cancer cell lines. The method was thoroughly validated for the accuracy and reproducibility through analyzing recombinant histone proteins and cellular samples. The linear dynamic range of the MRM assays was achieved in 3 orders of magnitude from 1 nM to 1 μM for all targeted peptides. Excellent intrabatch and interbatch reproducibility (<15% CV) was obtained. This method has been used to study translocated NSD2 (a histone lysine methyltransferase that catalyzes the histone lysine 36 methylation) function with its overexpression in KMS11 multiple myeloma cells. From the results we have successfully quantitated both individual and combinatorial histone marks in parental and NSD2 selective knockout KMS11 cells.

  10. Quantitative Proteomics Analysis of VEGF-Responsive Endothelial Protein S-Nitrosylation Using Stable Isotope Labeling by Amino Acids in Cell Culture (SILAC) and LC-MS/MS1

    PubMed Central

    Zhang, Hong-Hai; Lechuga, Thomas J.; Chen, Yuezhou; Yang, Yingying; Huang, Lan; Chen, Dong-Bao

    2016-01-01

    Adduction of a nitric oxide moiety (NO•) to cysteine(s), termed S-nitrosylation (SNO), is a novel mechanism for NO to regulate protein function directly. However, the endothelial SNO-protein network that is affected by endogenous and exogenous NO is obscure. This study was designed to develop a quantitative proteomics approach using stable isotope labeling by amino acids in cell culture for comparing vascular endothelial growth factor (VEGFA)- and NO donor-responsive endothelial nitroso-proteomes. Primary placental endothelial cells were labeled with “light” (L-12C614N4-Arg and L-12C614N2-Lys) or “heavy” (L-13C615N4-Arg and L-13C615N2-Lys) amino acids. The light cells were treated with an NO donor nitrosoglutathione (GSNO, 1 mM) or VEGFA (10 ng/ml) for 30 min, while the heavy cells received vehicle as control. Equal amounts of cellular proteins from the light (GSNO or VEGFA treated) and heavy cells were mixed for labeling SNO-proteins by the biotin switch technique and then trypsin digested. Biotinylated SNO-peptides were purified for identifying SNO-proteins by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Ratios of light to heavy SNO-peptides were calculated for determining the changes of the VEGFA- and GSNO-responsive endothelial nitroso-proteomes. A total of 387 light/heavy pairs of SNO-peptides were identified, corresponding to 213 SNO-proteins that include 125 common and 27 VEGFA- and 61 GSNO-responsive SNO-proteins. The specific SNO-cysteine(s) in each SNO-protein were simultaneously identified. Pathway analysis revealed that SNO-proteins are involved in various endothelial functions, including proliferation, motility, metabolism, and protein synthesis. We collectively conclude that endogenous NO on VEGFA stimulation and exogenous NO from GSNO affect common and different SNO-protein networks, implicating SNO as a critical mechanism for VEGFA stimulation of angiogenesis. PMID:27075618

  11. An impulse-driven liquid-droplet deposition interface for combining LC with MALDI MS and MS/MS.

    PubMed

    Young, J Bryce; Li, Liang

    2006-03-01

    A simple and robust impulse-driven droplet deposition system was developed for off-line liquid chromatography matrix-assisted laser desorption ionization mass spectrometry (LC-MALDI MS). The system uses a solenoid operated with a pulsed voltage power supply to generate impulses that dislodge the hanging droplets from the LC outlet directly to a MALDI plate via a momentum transfer process. There is no contact between the LC outlet and the collection surface. The system is compatible with solvents of varying polarity and viscosity, and accommodates the use of hydrophobic and hydrophilic MALDI matrices. MALDI spots are produced on-line with the separation, and do not require further processing before MS analysis. It is shown that high quality MALDI spectra from 5 fmol of pyro-Glu-fibrinopeptide deposition after LC separation could be obtained using the device, indicating that there was no sample loss in the interface. To demonstrate the analytical performance of the system as a proteome analysis tool, a range of BSA digest concentrations covering about 3 orders of magnitude, from 5 fmol to 1 pmol, were analyzed by LC-MALDI quadrupole time-of-flight MS, yielding 6 and 57% amino acid sequence coverage, respectively. In addition, a complex protein mixture of an E. coli cell extract was tryptically digested and analyzed by LC-MALDI MS, resulting in the detection of a total of 409 unique peptides from 100 fractions of 15-s intervals.

  12. EPA CRL MS014: Analysis of Aldicarb, Bromadiolone, Carbofuran, Oxamyl and Methomyl in Water by Multiple Reaction Monitoring Liquid Chromatography / Tandem Mass Spectrometry (LC/MS/MS)

    EPA Pesticide Factsheets

    Method MS014 describes procedures for solvent extraction of aldicarb, bromadiolone, carbofuran, oxamyl and methomyl from water samples, followed by analysis using liquid chromatography tandem mass spectrometry (LC-MS-MS).

  13. Development of an LC-MS/MS method for the determination of endogenous cortisol in hair using (13)C3-labeled cortisol as surrogate analyte.

    PubMed

    Binz, Tina M; Braun, Ueli; Baumgartner, Markus R; Kraemer, Thomas

    2016-10-15

    Hair cortisol levels are increasingly applied as a measure for stress in humans and mammals. Cortisol is an endogenous compound and is always present within the hair matrix. Therefore, "cortisol-free hair matrix" is a critical point for any analytical method to accurately quantify especially low cortisol levels. The aim of this project was to modify current methods used for hair cortisol analysis to more accurately determine low endogenous cortisol concentrations in hair. For that purpose, (13)C3-labeled cortisol, which is not naturally present in hair (above 13C natural abundance levels), was used for calibration and comparative validation applying cortisol versus (13)C3-labeled cortisol. Cortisol was extracted from 20mg hair (standard sample amount) applying an optimized single step extraction protocol. An LC-MS/MS method was developed for the quantitative analysis of cortisol using either cortisol or (13)C3-cortisol as calibrators and D7-cortisone as internal standard (IS). The two methods (cortisol/(13)C3-labeled cortisol) were validated in a concentration range up to 500pg/mg and showed good linearity for both analytes (cortisol: R(2)=0.9995; (13)C3-cortisol R(2)=0.9992). Slight differences were observed for limit of detection (LOD) (0.2pg/mg/0.1pg/mg) and limit of quantification (LOQ) (1pg/mg/0.5pg/mg). Precision was good with a maximum deviation of 8.8% and 10% for cortisol and (13)C3-cortisol respectively. Accuracy and matrix effects were good for both analytes except for the quality control (QC) low cortisol. QC low (2.5pg/mg) showed matrix effects (126.5%, RSD 35.5%) and accuracy showed a deviation of 26% when using cortisol to spike. These effects are likely to be caused by the unknown amount of endogenous cortisol in the different hair samples used to determine validation parameters like matrix effect, LOQ and accuracy. No matrix effects were observed for the high QC (400pg/mg) samples. Recovery was good with 92.7%/87.3% (RSD 9.9%/6.2%) for QC low and

  14. DBS-LC-MS/MS assay for caffeine: validation and neonatal application.

    PubMed

    Bruschettini, Matteo; Barco, Sebastiano; Romantsik, Olga; Risso, Francesco; Gennai, Iulian; Chinea, Benito; Ramenghi, Luca A; Tripodi, Gino; Cangemi, Giuliana

    2016-09-01

    DBS might be an appropriate microsampling technique for therapeutic drug monitoring of caffeine in infants. Nevertheless, its application presents several issues that still limit its use. This paper describes a validated DBS-LC-MS/MS method for caffeine. The results of the method validation showed an hematocrit dependence. In the analysis of 96 paired plasma and DBS clinical samples, caffeine levels measured in DBS were statistically significantly lower than in plasma but the observed differences were independent from hematocrit. These results clearly showed the need for extensive validation with real-life samples for DBS-based methods. DBS-LC-MS/MS can be considered to be a good alternative to traditional methods for therapeutic drug monitoring or PK studies in preterm infants.

  15. Structure Annotation and Quantification of Wheat Seed Oxidized Lipids by High-Resolution LC-MS/MS.

    PubMed

    Riewe, David; Wiebach, Janine; Altmann, Thomas

    2017-10-01

    Lipid oxidation is a process ubiquitous in life, but the direct and comprehensive analysis of oxidized lipids has been limited by available analytical methods. We applied high-resolution liquid chromatography-mass spectrometry (LC-MS) and tandem mass spectrometry (MS/MS) to quantify oxidized lipids (glycerides, fatty acids, phospholipids, lysophospholipids, and galactolipids) and implemented a platform-independent high-throughput-amenable analysis pipeline for the high-confidence annotation and acyl composition analysis of oxidized lipids. Lipid contents of 90 different naturally aged wheat ( Triticum aestivum ) seed stocks were quantified in an untargeted high-resolution LC-MS experiment, resulting in 18,556 quantitative mass-to-charge ratio features. In a posthoc liquid chromatography-tandem mass spectrometry experiment, high-resolution MS/MS spectra (5 mD accuracy) were recorded for 8,957 out of 12,080 putatively monoisotopic features of the LC-MS data set. A total of 353 nonoxidized and 559 oxidized lipids with up to four additional oxygen atoms were annotated based on the accurate mass recordings (1.5 ppm tolerance) of the LC-MS data set and filtering procedures. MS/MS spectra available for 828 of these annotations were analyzed by translating experimentally known fragmentation rules of lipids into the fragmentation of oxidized lipids. This led to the identification of 259 nonoxidized and 365 oxidized lipids by both accurate mass and MS/MS spectra and to the determination of acyl compositions for 221 nonoxidized and 295 oxidized lipids. Analysis of 15-year aged wheat seeds revealed increased lipid oxidation and hydrolysis in seeds stored in ambient versus cold conditions. © 2017 The author(s). All Rights Reserved.

  16. Underivatized oxysterols and nanoLC-ESI-MS: A mismatch.

    PubMed

    Roberg-Larsen, Hanne; Vesterdal, Caroline; Wilson, Steven Ray; Lundanes, Elsa

    2015-07-01

    Due to their non-charged character, liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) measurements of oxysterols are often performed after derivatization with e.g. charged Girard reagents. However, derivatization reactions are time-consuming and may require numerous steps to remove excess reagent. In addition, extensive sample handling can be associated with cholesterol autoxidation, resulting in analyte artifacts and hence false positives. Nano scale liquid chromatography in combination with electrospray-mass spectrometry (nanoLC-ESI-MS) is a powerful tool for analyzing limited samples, due to substantially increased sensitivity compared to conventional LC-ESI-MS. The signal enhancement may compensate for the poor ionization of the oxysterols; hence we have explored the possibility to quantify oxysterols without derivatization using nanoLC-ESI-MS. Non-derivatized oxysterols and nanoLC were however not compatible, due to persistent and large carry-over. This was attributed to the extended contribution of surface to volume ratio in such miniaturized systems and interactions with the materials of the nanoLC instrumentation (e.g. adsorption to the fused silica tubing). Two contemporary MS instruments (Q-Exactive™ hybrid quadrupole-Orbitrap and TSQ Quantiva™ triple quadrupole) were used. However, both the MS and MS/MS spectra of non-derivatized oxysterols were ambiguous and/or unrepeatable for both of the instruments employed. Derivatizing oxysterols is more cumbersome, but provides more selective and reliable results, and Girard derivatization+nanoLC-ESI-MS continues to be our recommended choice for measuring oxysterols in very limited samples. These investigations also indicate that extra care should be taken to remove lipids prior to nanoLC of other analytes, as adsorbed oxysterols, etc. can compromise analysis. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Combination of Bottom-up 2D-LC-MS and Semi-top-down GelFree-LC-MS Enhances Coverage of Proteome and Low Molecular Weight Short Open Reading Frame Encoded Peptides of the Archaeon Methanosarcina mazei.

    PubMed

    Cassidy, Liam; Prasse, Daniela; Linke, Dennis; Schmitz, Ruth A; Tholey, Andreas

    2016-10-07

    The recent discovery of an increasing number of small open reading frames (sORF) creates the need for suitable analytical technologies for the comprehensive identification of the corresponding gene products. For biological and functional studies the knowledge of the entire set of proteins and sORF gene products is essential. Consequently in the present study we evaluated analytical approaches that will allow for simultaneous analysis of widest parts of the proteome together with the predicted sORF. We performed a full proteome analysis of the methane producing archaeon Methanosarcina mazei strain Gö1 cytosolic proteome using a high/low pH reversed phase LC-MS bottom-up approach. The second analytical approach was based on semi-top-down strategy, encompassing a separation at intact protein level using a GelFree system, followed by digestion and LC-MS analysis. A high overlap in identified proteins was found for both approaches yielding the most comprehensive coverage of the cytosolic proteome of this organism achieved so far. The application of the second approach in combination with an adjustment of the search criteria for database searches further led to a significant increase of sORF peptide identifications, finally allowing to detect and identify 28 sORF gene products.

  18. Improvement of Nicotinic Acid and Nicotinamide Analysis in Meats and Meat Products by HPLC and LC-MS/MS with Solid-Phase Extraction.

    PubMed

    Hiki, Asako; Yamajima, Yukiko; Uematsu, Yoko

    2016-01-01

    A method for nicotinic acid (NA) and nicotinamide (NAA) analysis in meats was developed. NA and NAA were extracted from meats or meat products with metaphosphate aqueous solution. The extract was cleaned up with an Oasis MCX cartridge. The cartridge was washed with 2% acetic acid (v/v) and acetic acid-methanol solution. NA and NAA were eluted with ammonia-methanol solution. NA and NAA in the eluate were chromatographed on a Scherzo SM-C18 (3.0×150 mm, 3.0 μm) column with 20 mmol/L ammonium acetate containing 0.1% acetic acid-acetonitrile (97 : 3) as a mobile phase and were monitored at 261 nm. Quantification was performed by LC and LC-MS/MS. Calibration curves showed high linearity (correlation coefficient>0.998) between 1-25 μg/mL for LC and LC-MS/MS. Recoveries were 84-108% (CV≦5.8%) by HPLC and 79-105% (CV≦9.0%) by LC-MS/MS. The limit of quantitation for NA was 0.005-0.01 g/kg and that for NAA was 0.01-0.02 g/kg.

  19. A Collaborative Study: Determination of Mycotoxins in Corn, Peanut Butter, and Wheat Flour Using Stable Isotope Dilution Assay (SIDA) and Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS).

    PubMed

    Zhang, Kai; Schaab, Matthew R; Southwood, Gavin; Tor, Elizabeth R; Aston, Linda S; Song, Wenlu; Eitzer, Brian; Majumdar, Sanghamitra; Lapainis, Theodore; Mai, Huy; Tran, Kevin; El-Demerdash, Aref; Vega, Victor; Cai, Yanxuan; Wong, Jon W; Krynitsky, Alexandra J; Begley, Timothy H

    2017-08-23

    A collaborative study was conducted to evaluate stable isotope dilution assay (SIDA) and LC-MS/MS for the simultaneous determination of aflatoxins B 1 , B 2 , G 1 , and G 2 ; deoxynivalenol; fumonisins B 1 , B 2 , and B 3 ; ochratoxin A; HT-2 toxin; T-2 toxin; and zearalenone in foods. Samples were fortified with 12 13 C uniformly labeled mycotoxins ( 13 C-IS) corresponding to the native mycotoxins and extracted with acetonitrile/water (50:50 v/v), followed by centrifugation, filtration, and LC-MS/MS analysis. In addition to certified reference materials, the six participating laboratories analyzed corn, peanut butter, and wheat flour fortified with the 12 mycotoxins at concentrations ranging from 1.0 to 1000 ng/g. Using their available LC-MS/MS platform, each laboratory developed in-house instrumental conditions for analysis. The majority of recoveries ranged from 80 to 120% with relative standard derivations (RSDs) <20%. Greater than 90% of the average recoveries of the participating laboratories were in the range of 90-110%, with repeatability RSD r (within laboratory) < 10% and reproducibility RSD R (among laboratory) < 15%. All Z scores of the results of certified reference materials were between -2 and 2. Using 13 C-IS eliminated the need for matrix-matched calibration standards for quantitation, simplified sample preparation, and achieved simultaneous identification and quantitation of multiple mycotoxins in a simple LC-MS/MS procedure.

  20. Development of an LC-MS based enzyme activity assay for MurC: application to evaluation of inhibitors and kinetic analysis.

    PubMed

    Deng, Gejing; Gu, Rong-Fang; Marmor, Stephen; Fisher, Stewart L; Jahic, Haris; Sanyal, Gautam

    2004-06-29

    An enzyme activity assay, based on mass spectrometric (MS) detection of specific reaction product following HPLC separation, has been developed to evaluate pharmaceutical hits identified from primary high throughput screening (HTS) against target enzyme Escherichia coli UDP-N-acetyl-muramyl-L-alanine ligase (MurC), an essential enzyme in the bacterial peptidoglycan biosynthetic pathway, and to study the kinetics of the enzyme. A comparative analysis of this new liquid chromatographic-MS (LC-MS) based assay with a conventional spectrophotometric Malachite Green (MG) assay, which detects phosphate produced in the reaction, was performed. The results demonstrated that the LC-MS assay, which determines specific ligase activity of MurC, offers several advantages including a lower background (0.2% versus 26%), higher sensitivity (> or = 10 fold), lower limit of quantitation (LOQ) (0.02 microM versus 1 microM) and wider linear dynamic range (> or = 4 fold) than the MG assay. Good precision for the LC-MS assay was demonstrated by the low intraday and interday coefficient of variation (CV) values (3 and 6%, respectively). The LC-MS assay, free of the artifacts often seen in the Malachite Green assay, offers a valuable secondary assay for hit evaluation in which the false positives from the primary high throughput screening can be eliminated. In addition, the applicability of this assay to the study of enzyme kinetics has also been demonstrated. Copyright 2004 Elsevier B.V.

  1. A sensitive LC-MS/MS method for measurement of organophosphorus pesticides and their oxygen analogs in air sampling matrices

    PubMed Central

    ARMSTRONG, JENNA L.; DILLS, RUSSELL L.; YU, JIANBO; YOST, MICHAEL G.; FENSKE, RICHARD A.

    2018-01-01

    A rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed for determination of levels of the organophosphorus (OP) pesticides chlorpyrifos (CPF), azinphos methyl (AZM), and their oxygen analogs chlorpyrifos-oxon (CPF-O) and azinphos methyl-oxon (AZM-O) on common active air sampling matrices. XAD-2 resin and polyurethane foam (PUF) matrices were extracted with acetonitrile containing stable-isotope labeled internal standards (ISTD). Analysis was accomplished in Multiple Reaction Monitoring (MRM) mode, and analytes in unknown samples were identified by retention time (±0.1 min) and qualifier ratio (±30% absolute) as compared to the mean of calibrants. For all compounds, calibration linearity correlation coefficients were ≥0.996. Limits of detection (LOD) ranged from 0.15–1.1 ng/sample for CPF, CPF-O, AZM, and AZM-O on active sampling matrices. Spiked fortification recoveries were 78–113% from XAD-2 active air sampling tubes and 71–108% from PUF active air sampling tubes. Storage stability tests also yielded recoveries ranging from 74–94% after time periods ranging from 2–10 months. The results demonstrate that LC-MS/MS is a sensitive method for determining these compounds from two different matrices at the low concentrations that can result from spray drift and long range transport in non-target areas following agricultural applications. In an inter-laboratory comparison, the limit of quantification (LOQ) for LC-MS/MS was 100 times lower than a typical gas chromatography-mass spectrometry (GC-MS) method. PMID:24328542

  2. Validation and use of three complementary analytical methods (LC-FLS, LC-MS/MS and ICP-MS) to evaluate the pharmacokinetics, biodistribution and stability of motexafin gadolinium in plasma and tissues.

    PubMed

    Miles, Dale R; Mesfin, Mimi; Mody, Tarak D; Stiles, Mark; Lee, Jean; Fiene, John; Denis, Bernie; Boswell, Garry W

    2006-05-01

    Liquid chromatography-fluorescence (LC-FLS), liquid chromatography-tandem mass spectrometry (LC-MS/MS) and inductively coupled plasma-mass spectrometry (ICP-MS) methods were developed and validated for the evaluation of motexafin gadolinium (MGd, Xcytrin) pharmacokinetics and biodistribution in plasma and tissues. The LC-FLS method exhibited the greatest sensitivity (0.0057 microg mL(-1)), and was used for pharmacokinetic, biodistribution, and protein binding studies with small sample sizes or low MGd concentrations. The LC-MS/MS method, which exhibited a short run time and excellent selectivity, was used for routine clinical plasma sample analysis. The ICP-MS method, which measured total Gd, was used in conjunction with LC methods to assess MGd stability in plasma. All three methods were validated using human plasma. The LC-FLS method was also validated using plasma, liver and kidneys from mice and rats. All three methods were shown to be accurate, precise and robust for each matrix validated. For three mice, the mean (standard deviation) concentration of MGd in plasma/tissues taken 5 hr after dosing with 23 mg kg(-1) MGd was determined by LC-FLS as follows: plasma (0.025+/-0.002 microg mL(-1)), liver (2.89+/-0.45 microg g(-1)), and kidney (6.09+/-1.05 microg g(-1)). Plasma samples from a subset of patients with brain metastases from extracranial tumors were analyzed using both LC-MS/MS and ICP-MS methods. For a representative patient, > or = 90% of the total Gd in plasma was accounted for as MGd over the first hour post dosing. By 24 hr post dosing, 63% of total Gd was accounted for as MGd, indicating some metabolism of MGd.

  3. Absolute Quantitation of Glycosylation Site Occupancy Using Isotopically Labeled Standards and LC-MS

    NASA Astrophysics Data System (ADS)

    Zhu, Zhikai; Go, Eden P.; Desaire, Heather

    2014-06-01

    N-linked glycans are required to maintain appropriate biological functions on proteins. Underglycosylation leads to many diseases in plants and animals; therefore, characterizing the extent of glycosylation on proteins is an important step in understanding, diagnosing, and treating diseases. To determine the glycosylation site occupancy, protein N-glycosidase F (PNGase F) is typically used to detach the glycan from the protein, during which the formerly glycosylated asparagine undergoes deamidation to become an aspartic acid. By comparing the abundance of the resulting peptide containing aspartic acid against the one containing non-glycosylated asparagine, the glycosylation site occupancy can be evaluated. However, this approach can give inaccurate results when spontaneous chemical deamidation of the non-glycosylated asparagine occurs. To overcome this limitation, we developed a new method to measure the glycosylation site occupancy that does not rely on converting glycosylated peptides to their deglycosylated forms. Specifically, the overall protein concentration and the non-glycosylated portion of the protein are quantified simultaneously by using heavy isotope-labeled internal standards coupled with LC-MS analysis, and the extent of site occupancy is accurately determined. The efficacy of the method was demonstrated by quantifying the occupancy of a glycosylation site on bovine fetuin. The developed method is the first work that measures the glycosylation site occupancy without using PNGase F, and it can be done in parallel with glycopeptide analysis because the glycan remains intact throughout the workflow.

  4. Application of LC/MS/MS Techniques to Development of US ...

    EPA Pesticide Factsheets

    This presentation will describe the U.S. EPA’s drinking water and ambient water method development program in relation to the process employed and the typical challenges encountered in developing standardized LC/MS/MS methods for chemicals of emerging concern. The EPA’s Drinking Water Contaminant Candidate List and Unregulated Contaminant Monitoring Regulations, which are the driving forces behind drinking water method development, will be introduced. Three drinking water LC/MS/MS methods (Methods 537, 544 and a new method for nonylphenol) and two ambient water LC/MS/MS methods for cyanotoxins will be described that highlight some of the challenges encountered during development of these methods. This presentation will provide the audience with basic understanding of EPA's drinking water method development program and an introduction to two new ambient water EPA methods.

  5. Analysis of Mammalian Sphingolipids by Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS) and Tissue Imaging Mass Spectrometry (TIMS)

    PubMed Central

    Sullards, M. Cameron; Liu, Ying; Chen, Yanfeng; Merrill, Alfred H.

    2011-01-01

    Sphingolipids are a highly diverse category of molecules that serve not only as components of biological structures but also as regulators of numerous cell functions. Because so many of the structural features of sphingolipids give rise to their biological activity, there is a need for comprehensive or “sphingolipidomic” methods for identification and quantitation of as many individual subspecies as possible. This review defines sphingolipids as a class, briefly discusses classical methods for their analysis, and focuses primarily on liquid chromatography tandem mass spectrometry (LC-MS/MS) and tissue imaging mass spectrometry (TIMS). Recently, a set of evolving and expanding methods have been developed and rigorously validated for the extraction, identification, separation, and quantitation of sphingolipids by LC-MS/MS. Quantitation of these biomolecules is made possible via the use of an internal standard cocktail. The compounds that can be readily analyzed are free long-chain (sphingoid) bases, sphingoid base 1-phosphates, and more complex species such as ceramides, ceramide 1-phosphates, sphingomyelins, mono- and di-hexosylceramides sulfatides, and novel compounds such as the 1-deoxy- and 1-(deoxymethyl)-sphingoid bases and their N-acyl-derivatives. These methods can be altered slightly to separate and quantitate isomeric species such as glucosyl/galactosylceramide. Because these techniques require the extraction of sphingolipids from their native environment, any information regarding their localization in histological slices is lost. Therefore, this review also describes methods for TIMS. This technique has been shown to be a powerful tool to determine the localization of individual molecular species of sphingolipids directly from tissue slices. PMID:21749933

  6. Data Dependent Peak Model Based Spectrum Deconvolution for Analysis of High Resolution LC-MS Data

    PubMed Central

    2015-01-01

    A data dependent peak model (DDPM) based spectrum deconvolution method was developed for analysis of high resolution LC-MS data. To construct the selected ion chromatogram (XIC), a clustering method, the density based spatial clustering of applications with noise (DBSCAN), is applied to all m/z values of an LC-MS data set to group the m/z values into each XIC. The DBSCAN constructs XICs without the need for a user defined m/z variation window. After the XIC construction, the peaks of molecular ions in each XIC are detected using both the first and the second derivative tests, followed by an optimized chromatographic peak model selection method for peak deconvolution. A total of six chromatographic peak models are considered, including Gaussian, log-normal, Poisson, gamma, exponentially modified Gaussian, and hybrid of exponential and Gaussian models. The abundant nonoverlapping peaks are chosen to find the optimal peak models that are both data- and retention-time-dependent. Analysis of 18 spiked-in LC-MS data demonstrates that the proposed DDPM spectrum deconvolution method outperforms the traditional method. On average, the DDPM approach not only detected 58 more chromatographic peaks from each of the testing LC-MS data but also improved the retention time and peak area 3% and 6%, respectively. PMID:24533635

  7. ChelomEx: Isotope-assisted discovery of metal chelates in complex media using high-resolution LC-MS.

    PubMed

    Baars, Oliver; Morel, François M M; Perlman, David H

    2014-11-18

    Chelating agents can control the speciation and reactivity of trace metals in biological, environmental, and laboratory-derived media. A large number of trace metals (including Fe, Cu, Zn, Hg, and others) show characteristic isotopic fingerprints that can be exploited for the discovery of known and unknown organic metal complexes and related chelating ligands in very complex sample matrices using high-resolution liquid chromatography mass spectrometry (LC-MS). However, there is currently no free open-source software available for this purpose. We present a novel software tool, ChelomEx, which identifies isotope pattern-matched chromatographic features associated with metal complexes along with free ligands and other related adducts in high-resolution LC-MS data. High sensitivity and exclusion of false positives are achieved by evaluation of the chromatographic coherence of the isotope pattern within chromatographic features, which we demonstrate through the analysis of bacterial culture media. A built-in graphical user interface and compound library aid in identification and efficient evaluation of results. ChelomEx is implemented in MatLab. The source code, binaries for MS Windows and MAC OS X as well as test LC-MS data are available for download at SourceForge ( http://sourceforge.net/projects/chelomex ).

  8. Determination of advanced glycation endproducts by LC-MS/MS in raw and roasted almonds (Prunus dulcis).

    PubMed

    Zhang, Gong; Huang, Guangwei; Xiao, Lu; Mitchell, Alyson E

    2011-11-23

    A sensitive and reliable LC-(ESI)MS/MS method was developed and validated for the simultaneous analysis of five common advanced glycation endproducts (AGEs) after enzymatic digestion in raw and roasted almonds. AGEs included carboxymethyl-lysine (CML), carboxyethyl-lysine (CEL), pyralline (Pyr), argpyrimidine (Arg-p), and pentosidine (Pento-s). This method allows accurate quantitation of free and AGE-protein adducts of target AGEs. Results indicate that CML and CEL are found in both raw and roasted almonds. Pyr was identified for the first time in roasted almonds and accounted for 64.4% of free plus bound measured AGEs. Arg-p and Pento-s were below the limit of detection in all almond samples tested. Free AGEs accounted for 1.3-26.8% of free plus bound measured AGEs, indicating that protein-bound forms predominate. The roasting process significantly increased CML, CEL, and Pyr formation, but no significant correlation was observed between these AGEs and roasting temperature.

  9. Label-free shotgun proteomics and metabolite analysis reveal a significant metabolic shift during citrus fruit development

    PubMed Central

    Katz, Ehud; Boo, Kyung Hwan; Kim, Ho Youn; Eigenheer, Richard A.; Phinney, Brett S.; Shulaev, Vladimir; Negre-Zakharov, Florence; Sadka, Avi; Blumwald, Eduardo

    2011-01-01

    Label-free LC-MS/MS-based shot-gun proteomics was used to quantify the differential protein synthesis and metabolite profiling in order to assess metabolic changes during the development of citrus fruits. Our results suggested the occurrence of a metabolic change during citrus fruit maturation, where the organic acid and amino acid accumulation seen during the early stages of development shifted into sugar synthesis during the later stage of citrus fruit development. The expression of invertases remained unchanged, while an invertase inhibitor was up-regulated towards maturation. The increased expression of sucrose-phosphate synthase and sucrose-6-phosphate phosphatase and the rapid sugar accumulation suggest that sucrose is also being synthesized in citrus juice sac cells during the later stage of fruit development. PMID:21841177

  10. Multi-mycotoxin analysis of animal feed and animal-derived food using LC-MS/MS system with timed and highly selective reaction monitoring.

    PubMed

    Zhao, Zhiyong; Liu, Na; Yang, Lingchen; Deng, Yifeng; Wang, Jianhua; Song, Suquan; Lin, Shanhai; Wu, Aibo; Zhou, Zhenlei; Hou, Jiafa

    2015-09-01

    Mycotoxins have the potential to enter the human food chain through carry-over of contaminants from feed into animal-derived products. The objective of the study was to develop a reliable and sensitive method for the analysis of 30 mycotoxins in animal feed and animal-derived food (meat, edible animal tissues, and milk) using liquid chromatography-tandem mass spectrometry (LC-MS/MS). In the study, three extraction procedures, as well as various cleanup procedures, were evaluated to select the most suitable sample preparation procedure for different sample matrices. In addition, timed and highly selective reaction monitoring on LC-MS/MS was used to filter out isobaric matrix interferences. The performance characteristics (linearity, sensitivity, recovery, precision, and specificity) of the method were determined according to Commission Decision 2002/657/EC and 401/2006/EC. The established method was successfully applied to screening of mycotoxins in animal feed and animal-derived food. The results indicated that mycotoxin contamination in feed directly influenced the presence of mycotoxin in animal-derived food. Graphical abstract Multi-mycotoxin analysis of animal feed and animal-derived food using LC-MS/MS.

  11. Screening Antioxidants Using LC-MS: A Case Study with Cocoa

    PubMed Central

    Calderón, Angela I.; Wright, Brian J.; Hurst, W. Jeffrey; van Breemen, Richard B.

    2009-01-01

    Oxidative stress enhances pathological processes contributing to cancer, cardiovascular disease and neurodegenerative diseases, and dietary antioxidants may counteract these deleterious processes. Since rapid methods to evaluate and compare food products for antioxidant benefits are needed, a new assay based on liquid chromatography-mass spectrometry (LC-MS) was developed for the identification and quantitative analysis of antioxidants in complex natural product samples such as food extracts. This assay is based on the comparison of electrospray LC-MS profiles of sample extracts before and after treatment with reactive oxygen species such as hydrogen peroxide or DPPH (2,2-diphenyl-1-picrylhydrazyl radical). Using this assay, methanolic extracts of cocoa powder were analyzed, and procyanidins were found to be the most potent antioxidant species. These species were identified using LC-MS, LC-MS-MS, accurate mass measurement, and comparison with reference standards. Furthermore, LC-MS was used to determine the levels of these species in cocoa samples. Catechin and epicatechin were the most abundant antioxidants followed by their dimers and trimers. The most potent antioxidants in cocoa were trimers and dimers of catechin and epicatechin, such as procyanidin B2, followed by catechin and epicatechin. This new LC-MS assay facilitates the rapid identification and then the determination of the relative antioxidant activities of individual antioxidant species in complex natural product samples and food products such as cocoa. PMID:19489609

  12. A Method for Label-Free, Differential Top-Down Proteomics.

    PubMed

    Ntai, Ioanna; Toby, Timothy K; LeDuc, Richard D; Kelleher, Neil L

    2016-01-01

    Biomarker discovery in the translational research has heavily relied on labeled and label-free quantitative bottom-up proteomics. Here, we describe a new approach to biomarker studies that utilizes high-throughput top-down proteomics and is the first to offer whole protein characterization and relative quantitation within the same experiment. Using yeast as a model, we report procedures for a label-free approach to quantify the relative abundance of intact proteins ranging from 0 to 30 kDa in two different states. In this chapter, we describe the integrated methodology for the large-scale profiling and quantitation of the intact proteome by liquid chromatography-mass spectrometry (LC-MS) without the need for metabolic or chemical labeling. This recent advance for quantitative top-down proteomics is best implemented with a robust and highly controlled sample preparation workflow before data acquisition on a high-resolution mass spectrometer, and the application of a hierarchical linear statistical model to account for the multiple levels of variance contained in quantitative proteomic comparisons of samples for basic and clinical research.

  13. Simultaneous determination of water-soluble vitamins in beverages and dietary supplements by LC-MS/MS.

    PubMed

    Kakitani, Ayano; Inoue, Tomonori; Matsumoto, Keiko; Watanabe, Jun; Nagatomi, Yasushi; Mochizuki, Naoki

    2014-01-01

    An LC-MS/MS method was developed for the simultaneous determination of 15 water-soluble vitamins that are widely used as additives in beverages and dietary supplements. This combined method involves the following simple pre-treatment procedures: dietary supplement samples were prepared by centrifugation and filtration after an extraction step, whereas beverage samples were diluted prior to injection. Chromatographic analysis in this method utilised a multi-mode ODS column, which provided reverse-phase, anion- and cation-exchange capacities, and therefore improved the retention of highly polar analytes such as water-soluble vitamins. Additionally, the multi-mode ODS column did not require adding ion pair reagents to the mobile phase. We optimised the chromatographic separation of 15 water-soluble vitamins by adjusting the mobile phase pH and the organic solvent. We also conducted an analysis of a NIST Standard Reference Material (SRM 3280 Multi-vitamin/Multi-element tablets) using this method to verify its accuracy. In addition, the method was applied to identify the vitamins in commercial beverages and dietary supplements. By comparing results with the label values and results obtained by official methods, it was concluded that the method could be used for quality control and to compose nutrition labels for vitamin-enriched products.

  14. Metabolic profiling of roots of liquorice (Glycyrrhiza glabra) from different geographical areas by ESI/MS/MS and determination of major metabolites by LC-ESI/MS and LC-ESI/MS/MS.

    PubMed

    Montoro, Paola; Maldini, Mariateresa; Russo, Mariateresa; Postorino, Santo; Piacente, Sonia; Pizza, Cosimo

    2011-02-20

    Liquid chromatography electrospray mass spectrometry (LC-ESI/MS) has been applied to the full characterization of saponins and phenolics in hydroalcoholic extracts of roots of liquorice (Glycyrrhiza glabra). Relative quantitative analyses of the samples with respect to the phenolic constituents and to a group of saponins related to glycyrrhizic acid were performed using LC-ESI/MS. For the saponin constituents, full scan LC-MS/MS fragmentation of the protonated (positive ion mode) or deprotonated (negative ion mode) molecular species generated diagnostic fragment ions that provided information concerning the triterpene skeleton and the number and nature of the substituents. On the basis of the specific fragmentation of glycyrrhizic acid, an LC-MS/MS method was developed in order to quantify the analyte in the liquorice root samples. Chinese G. glabra roots contained the highest levels of glycyrrhizic acid, followed by those from Italy (Calabria). Copyright © 2010 Elsevier B.V. All rights reserved.

  15. Strategy to improve the quantitative LC-MS analysis of molecular ions resistant to gas-phase collision induced dissociation: application to disulfide-rich cyclic peptides.

    PubMed

    Ciccimaro, Eugene; Ranasinghe, Asoka; D'Arienzo, Celia; Xu, Carrie; Onorato, Joelle; Drexler, Dieter M; Josephs, Jonathan L; Poss, Michael; Olah, Timothy

    2014-12-02

    Due to observed collision induced dissociation (CID) fragmentation inefficiency, developing sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) assays for CID resistant compounds is especially challenging. As an alternative to traditional LC-MS/MS, we present here a methodology that preserves the intact analyte ion for quantification by selectively filtering ions while reducing chemical noise. Utilizing a quadrupole-Orbitrap MS, the target ion is selectively isolated while interfering matrix components undergo MS/MS fragmentation by CID, allowing noise-free detection of the analyte's surviving molecular ion. In this manner, CID affords additional selectivity during high resolution accurate mass analysis by elimination of isobaric interferences, a fundamentally different concept than the traditional approach of monitoring a target analyte's unique fragment following CID. This survivor-selected ion monitoring (survivor-SIM) approach has allowed sensitive and specific detection of disulfide-rich cyclic peptides extracted from plasma.

  16. Arsenic speciation and fucoxanthin analysis from seaweed dietary supplements using LC-MS

    USDA-ARS?s Scientific Manuscript database

    Inorganic species are considered more toxic to humans than organic arsenic and total arsenic. Analysis of total arsenic in metallic form, organic and inorganic arsenic species from seaweeds and dietary supplements using LC-ICP-MS was developed. Solvent extraction with sonication and microwave extr...

  17. A Label-Free Porous Silicon Immunosensor for Broad Detection of Opiates in a Blind Clinical Study and Result Comparison to Commercial Analytical Chemistry Techniques

    PubMed Central

    Bonanno, Lisa M.; Kwong, Tai C.; DeLouise, Lisa A.

    2010-01-01

    In this work we evaluate for the first time the performance of a label-free porous silicon (PSi) immunosensor assay in a blind clinical study designed to screen authentic patient urine specimens for a broad range of opiates. The PSi opiate immunosensor achieved 96% concordance with liquid chromatography-mass spectrometry/tandem mass spectrometry (LC-MS/MS) results on samples that underwent standard opiate testing (n=50). In addition, successful detection of a commonly abused opiate, oxycodone, resulted in 100% qualitative agreement between the PSi opiate sensor and LC-MS/MS. In contrast, a commercial broad opiate immunoassay technique (CEDIA®) achieved 65% qualitative concordance with LC-MS/MS. Evaluation of important performance attributes including precision, accuracy, and recovery was completed on blank urine specimens spiked with test analytes. Variability of morphine detection as a model opiate target was < 9% both within-run and between-day at and above the cutoff limit of 300 ng ml−1. This study validates the analytical screening capability of label-free PSi opiate immunosensors in authentic patient samples and is the first semi-quantitative demonstration of the technology’s successful clinical use. These results motivate future development of PSi technology to reduce complexity and cost of diagnostic testing particularly in a point-of-care setting. PMID:21062030

  18. High throughput LC-MS/MS method for the simultaneous analysis of multiple vitamin D analytes in serum.

    PubMed

    Jenkinson, Carl; Taylor, Angela E; Hassan-Smith, Zaki K; Adams, John S; Stewart, Paul M; Hewison, Martin; Keevil, Brian G

    2016-03-01

    Recent studies suggest that vitamin D-deficiency is linked to increased risk of common human health problems. To define vitamin D 'status' most routine analytical methods quantify one particular vitamin D metabolite, 25-hydroxyvitamin D3 (25OHD3). However, vitamin D is characterized by complex metabolic pathways, and simultaneous measurement of multiple vitamin D metabolites may provide a more accurate interpretation of vitamin D status. To address this we developed a high-throughput liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to analyse multiple vitamin D analytes, with particular emphasis on the separation of epimer metabolites. A supportive liquid-liquid extraction (SLE) and LC-MS/MS method was developed to quantify 10 vitamin D metabolites as well as separation of an interfering 7α-hydroxy-4-cholesten-3-one (7αC4) isobar (precursor of bile acid), and validated by analysis of human serum samples. In a cohort of 116 healthy subjects, circulating concentrations of 25-hydroxyvitamin D3 (25OHD3), 3-epi-25-hydroxyvitamin D3 (3-epi-25OHD3), 24,25-dihydroxyvitamin D3 (24R,25(OH)2D3), 1,25-dihydroxyvitamin D3 (1α,25(OH)2D3), and 25-hydroxyvitamin D2 (25OHD2) were quantifiable using 220μL of serum, with 25OHD3 and 24R,25(OH)2D3 showing significant seasonal variations. This high-throughput LC-MS/MS method provides a novel strategy for assessing the impact of vitamin D on human health and disease. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Application of LC-MS/MS MRM to Determine Staphylococcal Enterotoxins (SEB and SEA) in Milk.

    PubMed

    Andjelkovic, Mirjana; Tsilia, Varvara; Rajkovic, Andreja; De Cremer, Koen; Van Loco, Joris

    2016-04-20

    Staphylococcus aureus is one of the important aetiological agents of food intoxications in Europe and can cause gastro-enteritis through the production of various staphylococcal enterotoxins (SEs) in foods. Due to their stability and ease of production and dissemination, some SEs have also been studied as potential agents for bioterrorism. Therefore, specific and accurate analytical tools are required to detect and quantify SEs. Online solid-phase extraction liquid chromatography electrospray ionization tandem mass spectrometry (online SPE-LC-ESI-MS/MS) based on multiple reaction monitoring (MRM) was used to detect and quantify two types of SE (A and B) spiked in milk and buffer solution. SE extraction and concentration was performed according to the European Screening Method developed by the European Reference Laboratory for Coagulase Positive Staphylococci. Trypsin digests were screened for the presence of SEs using selected proteotypic heavy-labeled peptides as internal standards. SEA and SEB were successfully detected in milk samples using LC-MS/MS in MRM mode. The selected SE peptides were proteotypic for each toxin, allowing the discrimination of SEA and SEB in a single run. The detection limit of SEA and SEB was approximately 8 and 4 ng/g, respectively.

  20. Authentication of Trappist beers by LC-MS fingerprints and multivariate data analysis.

    PubMed

    Mattarucchi, Elia; Stocchero, Matteo; Moreno-Rojas, José Manuel; Giordano, Giuseppe; Reniero, Fabiano; Guillou, Claude

    2010-12-08

    The aim of this study was to asses the applicability of LC-MS profiling to authenticate a selected Trappist beer as part of a program on traceability funded by the European Commission. A total of 232 beers were fingerprinted and classified through multivariate data analysis. The selected beer was clearly distinguished from beers of different brands, while only 3 samples (3.5% of the test set) were wrongly classified when compared with other types of beer of the same Trappist brewery. The fingerprints were further analyzed to extract the most discriminating variables, which proved to be sufficient for classification, even using a simplified unsupervised model. This reduced fingerprint allowed us to study the influence of batch-to-batch variability on the classification model. Our results can easily be applied to different matrices and they confirmed the effectiveness of LC-MS profiling in combination with multivariate data analysis for the characterization of food products.

  1. Quantitation of intracellular purine intermediates in different Corynebacteria using electrospray LC-MS/MS.

    PubMed

    Peifer, Susanne; Schneider, Konstantin; Nürenberg, Gudrun; Volmer, Dietrich A; Heinzle, Elmar

    2012-11-01

    Intermediates of the purine biosynthesis pathway play key roles in cellular metabolism including nucleic acid synthesis and signal mediation. In addition, they are also of major interest to the biotechnological industry as several intermediates either possess flavor-enhancing characteristics or are applied in medical therapy. In this study, we have developed an analytical method for quantitation of 12 intermediates from the purine biosynthesis pathway including important nucleotides and their corresponding nucleosides and nucleobases. The approach comprised a single-step acidic extraction/quenching procedure, followed by quantitative electrospray LC-MS/MS analysis. The assay was validated in terms of accuracy, precision, reproducibility, and applicability for complex biological matrices. The method was subsequently applied for determination of free intracellular pool sizes of purine biosynthetic pathway intermediates in the two Gram-positive bacteria Corynebacterium glutamicum and Corynebacterium ammoniagenes. Importantly, no ion pair reagents were applied in this approach as usually required for liquid chromatography analysis of large classes of diverse metabolites.

  2. Development and validation of an LC-ESI-MS/MS method for the quantification of D-84, reboxetine and citalopram for their use in MS Binding Assays addressing the monoamine transporters hDAT, hSERT and hNET.

    PubMed

    Neiens, Patrick; De Simone, Angela; Ramershoven, Anna; Höfner, Georg; Allmendinger, Lars; Wanner, Klaus T

    2018-03-03

    MS Binding Assays represent a label-free alternative to radioligand binding assays. In this study, we present an LC-ESI-MS/MS method for the quantification of (R,R)-4-(2-benzhydryloxyethyl)-1-(4-fluorobenzyl)piperidin-3-ol [(R,R)-D-84, (R,R)-1], (S,S)-reboxetine [(S,S)-2], and (S)-citalopram [(S)-3] employed as highly selective nonlabeled reporter ligands in MS Binding Assays addressing the dopamine [DAT, (R,R)-D-84], norepinephrine [NET, (S,S)-reboxetine] and serotonin transporter [SERT, (S)-citalopram], respectively. The developed LC-ESI-MS/MS method uses a pentafluorphenyl stationary phase in combination with a mobile phase composed of acetonitrile and ammonium formate buffer for chromatography and a triple quadrupole mass spectrometer in the multiple reaction monitoring mode for mass spectrometric detection. Quantification is based on deuterated derivatives of all three analytes serving as internal standards. The established LC-ESI-MS/MS method enables fast, robust, selective and highly sensitive quantification of all three reporter ligands in a single chromatographic run. The method was validated according to the Center for Drug Evaluation and Research (CDER) guideline for bioanalytical method validation regarding selectivity, accuracy, precision, calibration curve and sensitivity. Finally, filtration-based MS Binding Assays were performed for all three monoamine transporters based on this LC-ESI-MS/MS quantification method as read out. The affinities determined in saturation experiments for (R,R)-D-84 toward hDAT, for (S,S)-reboxetine toward hNET, and for (S)-citalopram toward hSERT, respectively, were in good accordance with results from literature, clearly demonstrating that the established MS Binding Assays have the potential to be an efficient alternative to radioligand binding assays widely used for this purpose so far. Copyright © 2018 John Wiley & Sons, Ltd.

  3. LC-MS Analysis of Phenolic Compounds in Tubers Showing Zebra Chip Symptoms

    USDA-ARS?s Scientific Manuscript database

    A new potato disorder called zebra chip (ZC) has been identified in the United States and has been especially problematic in Texas where substantial economic losses have been incurred. Upon frying, ZC tubers develop a dark “zebra chip” pattern of discoloration. LC-MS analysis of symptomatic tubers...

  4. Time resolved analysis of quetiapine and 7-OH-quetiapine in hair using LC/MS-MS.

    PubMed

    Binz, Tina M; Yegles, Michel; Schneider, Serge; Neels, Hugo; Crunelle, Cleo L

    2014-09-01

    Hair analysis is a powerful tool for retrospective drug analysis and has a wide application window. This article describes the simultaneous determination and quantification of the short-acting atypical antipsychotic drug quetiapine and its main metabolite 7-OH quetiapine in hair. A sensitive and accurate method for the determination of these two compounds was developed using high-performance liquid chromatography coupled to tandem mass spectrometry detection (LC-MS/MS). The method was applied to 10 real case samples. For five patients, a time resolved hair analysis was done. Results varied from 0.35 ng/mg to 10.21 ng/mg hair for quetiapine and from 0.02 ng/mg to 3.19 ng/mg hair for 7-OH-quetiapine. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  5. Salivary hormone measurement using LC/MS/MS: specific and patient-friendly tool for assessment of endocrine function.

    PubMed

    Higashi, Tatsuya

    2012-01-01

    Saliva has recently been attracting attention as a patient-friendly available bio-fluid and an alternative to serum/plasma for hormone tests. LC coupled with atmospheric pressure ionization-MS/MS, especially electrospray ionization (ESI)-MS/MS, has been recently valued as a highly specific method in the analysis of salivary hormones. In this article, LC/ESI-MS/MS assays for salivary hormones are overviewed according to the papers that have been published during the last 5 years. Practical derivatization to enhance the detectabilities of hormones in ESI-MS/MS is also discussed, because a major disadvantage of using saliva is low hormone concentrations.

  6. Offline pentafluorophenyl (PFP)-RP prefractionation as an alternative to high-pH RP for comprehensive LC-MS/MS proteomics and phosphoproteomics.

    PubMed

    Grassetti, Andrew V; Hards, Rufus; Gerber, Scott A

    2017-07-01

    Technological advances in liquid chromatography and tandem mass spectrometry (LC-MS/MS) have enabled comprehensive analyses of proteins and their post-translational modifications from cell culture and tissue samples. However, sample complexity necessitates offline prefractionation via a chromatographic method that is orthogonal to online reversed-phase high-performance liquid chromatography (RP-HPLC). This additional fractionation step improves target identification rates by reducing the complexity of the sample as it is introduced to the instrument. A commonly employed offline prefractionation method is high pH reversed-phase (Hi-pH RP) chromatography. Though highly orthogonal to online RP-HPLC, Hi-pH RP relies on buffers that interfere with electrospray ionization. Thus, samples that are prefractionated using Hi-pH RP are typically desalted prior to LC-MS/MS. In the present work, we evaluate an alternative offline prefractionation method, pentafluorophenyl (PFP)-based reversed-phase chromatography. Importantly, PFP prefractionation results in samples that are dried prior to analysis by LC-MS/MS. This reduction in sample handling relative to Hi-pH RP results in time savings and could facilitate higher target identification rates. Here, we have compared the performances of PFP and Hi-pH RP in offline prefractionation of peptides and phosphopeptides that have been isolated from human cervical carcinoma (HeLa) cells. Given the prevalence of isobaric mass tags for peptide quantification, we evaluated PFP chromatography of peptides labeled with tandem mass tags. Our results suggest that PFP is a viable alternative to Hi-pH RP for both peptide and phosphopeptide offline prefractionation.

  7. Simultaneous determination of 117 pesticides and 30 mycotoxins in raw coffee, without clean-up, by LC-ESI-MS/MS analysis.

    PubMed

    Reichert, Bárbara; de Kok, André; Pizzutti, Ionara Regina; Scholten, Jos; Cardoso, Carmem Dickow; Spanjer, Martien

    2018-04-03

    This paper describes the optimization and validation of an acetonitrile based method for simultaneous extraction of multiple pesticides and mycotoxins from raw coffee beans followed by LC-ESI-MS/MS determination. Before extraction, the raw coffee samples were milled and then slurried with water. The slurried samples were spiked with two separate standard solutions, one containing 131 pesticides and a second with 35 mycotoxins, which were divided into 3 groups of different relative concentration levels. Optimization of the QuEChERS approach included performance tests with acetonitrile acidified with acetic acid or formic acid, with or without buffer and with or without clean-up of the extracts before LC-ESI-MS/MS analysis. For the clean-up step, seven d-SPE sorbents and their various mixtures were evaluated. After method optimization a complete validation study was carried out to ensure adequate performance of the extraction and chromatographic methods. The samples were spiked at 3 concentrations levels with both mycotoxins and pesticides (with 6 replicates at each level, n = 6) and then submitted to the extraction procedure. Before LC-ESI-MS/MS analysis, the acetonitrile extracts were diluted 2-fold with methanol, in order to improve the chromatographic performance of the early-eluting polar analytes. Calibration standard solutions were prepared in organic solvent and in blank coffee extract at 7 concentration levels and analyzed 6 times each. The method was assessed for accuracy (recovery %), precision (RSD%), selectivity, linearity (r 2 ), limit of quantification (LOQ) and matrix effects (%). Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Stable isotope labeling-solid phase extraction-mass spectrometry analysis for profiling of thiols and aldehydes in beer.

    PubMed

    Zheng, Shu-Jian; Wang, Ya-Lan; Liu, Ping; Zhang, Zheng; Yu, Lei; Yuan, Bi-Feng; Feng, Yu-Qi

    2017-12-15

    In this study, we developed a strategy for profiling of thiols and aldehydes in beer samples by stable isotope labeling-solid phase extraction-liquid chromatography-double precursor ion scan/double neutral loss scan-mass spectrometry analysis (SIL-SPE-LC-DPIS/DNLS-MS). A pair of isotope reagents (ω-bromoacetonylquinolinium bromide, BQB; ω-bromoacetonylquinolinium-d 7 bromide, BQB-d 7 ) were used to label thiols; while for the aldehydes, a pair of isotope reagents (4-(2-(trimethylammonio) ethoxy) benzenaminium halide, 4-APC; 4-(2-(trimethylammonio) ethoxy) benzenaminium halide-d 4 , 4-APC-d 4 ) were used. The labeled thiols and aldehydes were extracted and purified with solid-phase extraction, respectively, followed by LC-MS analysis. Using the proposed SIL-SPE-LC-DPIS/DNLS-MS methods, 76 thiol and 25 aldehyde candidates were found in beer. Furthermore, we established SIL-SPE-LC-MRM-MS methods for the relative quantitation of thiols and aldehydes in different beer samples. The results showed that the contents of thiols and aldehydes are closely related to the brands and origins of beers. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. LC-IMS-MS Feature Finder

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2013-03-07

    LC-IMS-MS Feature Finder is a command line software application which searches for possible molecular ion signatures in multidimensional liquid chromatography, ion mobility spectrometry, and mass spectrometry data by clustering deisotoped peaks with similar monoisotopic mass values, charge states, elution times, and drift times. The software application includes an algorithm for detecting multiple conformations and co-eluting species in the ion mobility dimension. LC-IMS-MS Feature Finder is designed to create an output file with detected features that includes associated information about the detected features.

  10. Simultaneous determination of five coumarins in Angelicae dahuricae Radix by HPLC/UV and LC-ESI-MS/MS.

    PubMed

    Park, Ah Yeon; Park, So-Young; Lee, Jaehyun; Jung, Mihye; Kim, Jinwoong; Kang, Sam Sik; Youm, Jeong-Rok; Han, Sang Beom

    2009-10-01

    Rapid, simple and reliable HPLC/UV and LC-ESI-MS/MS methods for the simultaneous determination of five active coumarins of Angelicae dahuricae Radix, byakangelicol (1), oxypeucedanin (2), imperatorin (3), phellopterin (4) and isoimperatorin (5) were developed and validated. The separation condition for HPLC/UV was optimized using a Develosil RPAQUEOUS C(30) column using 70% acetonitrile in water as the mobile phase. This HPLC/UV method was successful for providing the baseline separation of the five coumarins with no interfering peaks detected in the 70% ethanol extract of Angelicae dahuricae Radix. The specific determination of the five coumarins was also accomplished by a triple quadrupole tandem mass spectrometer equipped with an electrospray ionization source (LC-ESI-MS/MS). Multiple reaction monitoring (MRM) in the positive mode was used to enhance the selectivity of detection. The LC-ESI-MS/MS methods were successfully applied for the determination of the five major coumarins in Angelicae dahuricae Radix. These HPLC/UV and LC-ESI-MS/MS methods were validated in terms of recovery, linearity, accuracy and precision (intra- and inter-day validation). Taken together, the shorter analysis time involved makes these HPLC/UV and LC-ESI-MS/MS methods valuable for the commercial quality control of Angelicae dahuricae Radix extracts and its pharmaceutical preparations. Copyright (c) 2009 John Wiley & Sons, Ltd.

  11. Using LC-MS to examine the fermented food products vinegar and soy sauce for the presence of gluten.

    PubMed

    Li, Haili; Byrne, Keren; Galiamov, Renata; Mendoza-Porras, Omar; Bose, Utpal; Howitt, Crispin A; Colgrave, Michelle L

    2018-07-15

    A strict, lifelong gluten-free (GF) diet is currently the only treatment for coeliac disease (CD). Vinegar and soy sauce are fermented condiments that often include wheat and/or barley. During fermentation cereal proteins are partially degraded by enzymes to yield peptide fragments and amino acids. Whether these fermented products contain intact or degraded gluten proteins and if they are safe for people with CD remains in question. LC-MS offers the benefit of being able to detect hydrolysed gluten that might be present in commercial vinegar and soy sauce products. LC-MS revealed the presence of gluten in malt vinegar, wherein the identified peptides derived from B-, D- and γ-hordein from barley, as well as γ-gliadin, and HMW- and LMW-glutenins from wheat that are known to contain immunopathogenic epitopes. No gluten was detected in the soy sauces examined despite wheat being a labelled ingredient indicating extensive hydrolysis of gluten during soy sauce production. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Optimisation and validation of the analytical procedure for the determination of acrylamide in coffee by LC-MS/MS with SPE clean up.

    PubMed

    Gielecińska, Iwona; Mojska, Hanna

    2013-01-01

    Numerous studies have demonstrated acrylamide to be both neurotoxic and carcinogenic. At present it is widely recognised that acrylamide is mainly formed through the Maillard reaction from free asparagine and reducing sugars. The major sources of dietary acrylamide are potato products, processed cereals and coffee. To optimise and validate an analytical method for determining acrylamide in coffee by liquid chromatography and tandem mass spectrometry analysis (LC/MS/MS) using SPE clean-up. Analytical separation of acrylamide from roasted coffee was performed by liquid chromatography using a Hypercarb column followed by LC/MS/MS analysis, with 2,3,3-d3 acrylamide as an internal standard. The method was based on two purification steps: the first with hexane and Carrez solutions in order to remove of fat and to precipitate proteins, respectively; and the second with a solid-phase extraction (SPE) column which proved to be efficient in the elimination of the main chromatographic interferences. Limit of quantification (LOQ) for measuring acrylamide in coffee was 50 microg/kg. The described method demonstrates satisfactory precision (RSD = 2.5%), repeatability (RSD = 9.2%) and accuracy (mean recovery - 97.4%). Our results confirm that LC-MS/MS with SPE clean-up is selective and suitable for determination of acrylamide in coffee. Indeed, this method meets the criteria of EU Commission Recommendations (No. 2007/331/EC and No. 2010/307/EU), on the monitoring of acrylamide levels in food.

  13. Comparative analysis of soybean plasma membrane proteins under osmotic stress using gel-based and LC MS/MS-based proteomics approaches.

    PubMed

    Nouri, Mohammad-Zaman; Komatsu, Setsuko

    2010-05-01

    To study the soybean plasma membrane proteome under osmotic stress, two methods were used: a gel-based and a LC MS/MS-based proteomics method. Two-day-old seedlings were subjected to 10% PEG for 2 days. Plasma membranes were purified from seedlings using a two-phase partitioning method and their purity was verified by measuring ATPase activity. Using the gel-based proteomics, four and eight protein spots were identified as up- and downregulated, respectively, whereas in the nanoLC MS/MS approach, 11 and 75 proteins were identified as up- and downregulated, respectively, under PEG treatment. Out of osmotic stress responsive proteins, most of the transporter proteins and all proteins with high number of transmembrane helices as well as low-abundance proteins could be identified by the LC MS/MS-based method. Three homologues of plasma membrane H(+)-ATPase, which are transporter proteins involved in ion efflux, were upregulated under osmotic stress. Gene expression of this protein was increased after 12 h of stress exposure. Among the identified proteins, seven proteins were mutual in two proteomics techniques, in which calnexin was the highly upregulated protein. Accumulation of calnexin in plasma membrane was confirmed by immunoblot analysis. These results suggest that under hyperosmotic conditions, calnexin accumulates in the plasma membrane and ion efflux accelerates by upregulation of plasma membrane H(+)-ATPase protein.

  14. Development and validation of an LC-MS/MS method for quantification of cyclic guanosine 3',5'-monophosphate (cGMP) in clinical applications: a comparison with a EIA method.

    PubMed

    Zhang, Yanhua; Dufield, Dawn; Klover, Jon; Li, Wenlin; Szekely-Klepser, Gabriella; Lepsy, Christopher; Sadagopan, Nalini

    2009-02-15

    An LC-MS/MS method was developed and validated to quantify endogenous cyclic guanosine 3',5'-monophosphate (cGMP) in human plasma. The LC-MS/MS and competitive enzyme immunoassay (EIA) assays were compared. cGMP concentrations of 20 human plasma samples were measured by both methods. For the MS-based assay, plasma samples were subjected to a simple protein precipitation procedure by acetonitrile prior to analysis by electrospray ionization LC-MS/MS. De-protonated analytes generated in negative ionization mode were monitored through multiple reaction monitoring (MRM). A stable isotope-labeled internal standard, (13)C(10),(15)N(5)-cGMP, which was biosynthesized in-house, was used in the LC-MS/MS method. The competitive EIA was validated using a commercially available cGMP fluorescence assay kit. The intra-assay accuracy and precision for MS-based assay for cGMP were 6-10.1% CV and -3.6% to 7.3% relative error (RE), respectively, while inter-assay precision and accuracy were 5.6-8.1% CV and -2.1% to 6.3% RE, respectively. The intra-assay accuracy and precision for EIA were 17.9-27.1% CV and -4.9% to 24.5% RE, respectively, while inter-assay precision and accuracy were 15.1-39.5% CV and -30.8% to 4.37% RE, respectively. Near the lower limits of detection, there was little correlation between the cGMP concentration values in human plasma generated by these two methods (R(2)=0.197, P=0.05). Overall, the MS-based assay offered better selectivity, recovery, precision and accuracy over a linear range of 0.5-20ng/mL. The LC-MS/MS method provides an effective tool for the quantitation of cGMP to support clinical mechanistic studies of curative pharmaceuticals.

  15. A multiclass multiresidue LC-MS/MS method for analysis of veterinary drugs in bovine kidney

    USDA-ARS?s Scientific Manuscript database

    The increased efficiency permitted by multiclass, multiresidue methods has made such approaches very attractive to laboratories involved in monitoring veterinary drug residues in animal tissues. In this current work, evaluation of a multiclass multiresidue LC-MS/MS method in bovine kidney is describ...

  16. Adhesive blood microsampling systems for steroid measurement via LC-MS/MS in the rat.

    PubMed

    Heussner, Kirsten; Rauh, Manfred; Cordasic, Nada; Menendez-Castro, Carlos; Huebner, Hanna; Ruebner, Matthias; Schmidt, Marius; Hartner, Andrea; Rascher, Wolfgang; Fahlbusch, Fabian B

    2017-04-01

    Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS) allows for the direct analysis of multiple hormones in a single probe with minimal sample volume. Rodent-based animal studies strongly rely on microsampling, such as the dry blood spot (DBS) method. However, DBS suffers the drawback of hematocrit-dependence (non-volumetric). Hence, novel volumetric microsampling techniques were introduced recently, allowing sampling of fixed accurate volumes. We compared these methods for steroid analysis in the rat to improve inter-system comparability. We analyzed steroid levels in blood using the absorptive microsampling devices Whatman® 903 Protein Saver Cards, Noviplex™ Plasma Prep Cards and the Mitra™ Microsampling device and compared the obtained results to the respective EDTA plasma levels. Quantitative steroid analysis was performed via LC-MS/MS. For the determination of the plasma volume factor for each steroid, their levels in pooled blood samples from each human adults and rats (18weeks) were compared and the transferability of these factors was evaluated in a new set of juvenile (21days) and adult (18weeks) rats. Hematocrit was determined concomitantly. Using these approaches, we were unable to apply one single volume factor for each steroid. Instead, plasma volume factors had to be adjusted for the recovery rate of each steroid and device individually. The tested microsampling systems did not allow the use of one single volume factor for adult and juvenile rats based on an unexpectedly strong hematocrit-dependency and other steroid specific (pre-analytic) factors. Our study provides correction factors for LC-MS/MS steroid analysis of volumetric and non-volumetric microsampling systems in comparison to plasma. It argues for thorough analysis of chromatographic effects before the use of novel volumetric systems for steroid analysis. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. The Short Cosyntropin Test Revisited: New Normal Reference Range Using LC-MS/MS.

    PubMed

    Ueland, Grethe Å; Methlie, Paal; Øksnes, Marianne; Thordarson, Hrafnkell B; Sagen, Jørn; Kellmann, Ralf; Mellgren, Gunnar; Ræder, Maria; Dahlqvist, Per; Dahl, Sandra R; Thorsby, Per M; Løvås, Kristian; Husebye, Eystein S

    2018-04-01

    The cosyntropin test is used to diagnose adrenal insufficiency (AI) and nonclassical congenital adrenal hyperplasia (NCCAH). Current cutoffs for cortisol and 17-hydroxyprogesterone (17-OHP) are derived from nonstandardized immunoassays. Liquid chromatography tandem mass spectrometry (LC-MS/MS) offers direct measurement of steroids, prompting the need to re-establish normal ranges. The goal of this study was to define cutoff values for cortisol and 17-OHP in serum by LC-MS/MS 30 and 60 minutes after intravenous administration of 250 µg tetracosactide acetate to healthy volunteers and to compare the results with LC-MS/MS with routine immunoassays. Cosyntropin testing was performed in healthy subjects (n = 138) and in patients referred for evaluation of adrenocortical function (n = 94). Steroids were assayed by LC-MS/MS and compared with two immunoassays used in routine diagnostics (Immulite and Roche platforms). The cutoff level for cortisol was defined as the 2.5% percentile in healthy subjects not using oral estrogens (n = 121) and for 17-OHP as the 97.5% percentile. Cortisol cutoff levels for LC-MS/MS were 412 and 485 nmol/L at 30 and 60 minutes, respectively. Applying the new cutoffs, 13 of 60 (22%) subjects who had AI according to conventional criteria now had a normal test result. For 17-OHP, the cutoff levels were 8.9 and 9.0 nmol/L at 30 and 60 minutes, respectively. LC-MS/MS provides cutoff levels for cortisol and 17-OHP after cosyntropin stimulation that are lower than those based on immunoassays, possibly because cross-reactivity between steroid intermediates and cortisol is eliminated. This reduces the number of false-positive tests for AI and false-negative tests for NCCAH.

  18. LC-MS n Analysis of Isomeric Chondroitin Sulfate Oligosaccharides Using a Chemical Derivatization Strategy

    NASA Astrophysics Data System (ADS)

    Huang, Rongrong; Pomin, Vitor H.; Sharp, Joshua S.

    2011-09-01

    Improved methods for structural analyses of glycosaminoglycans (GAGs) are required to understand their functional roles in various biological processes. Major challenges in structural characterization of complex GAG oligosaccharides using liquid chromatography-mass spectrometry (LC-MS) include the accurate determination of the patterns of sulfation due to gas-phase losses of the sulfate groups upon collisional activation and inefficient on-line separation of positional sulfation isomers prior to MS/MS analyses. Here, a sequential chemical derivatization procedure including permethylation, desulfation, and acetylation was demonstrated to enable both on-line LC separation of isomeric mixtures of chondroitin sulfate (CS) oligosaccharides and accurate determination of sites of sulfation by MS n . The derivatized oligosaccharides have sulfate groups replaced with acetyl groups, which are sufficiently stable to survive MS n fragmentation and reflect the original sulfation patterns. A standard reversed-phase LC-MS system with a capillary C18 column was used for separation, and MS n experiments using collision-induced dissociation (CID) were performed. Our results indicate that the combination of this derivatization strategy and MS n methodology enables accurate identification of the sulfation isomers of CS hexasaccharides with either saturated or unsaturated nonreducing ends. Moreover, derivatized CS hexasaccharide isomer mixtures become separable by LC-MS method due to different positions of acetyl modifications.

  19. High-throughput quantitation of amino acids in rat and mouse biological matrices using stable isotope labeling and UPLC-MS/MS analysis.

    PubMed

    Takach, Edward; O'Shea, Thomas; Liu, Hanlan

    2014-08-01

    Quantifying amino acids in biological matrices is typically performed using liquid chromatography (LC) coupled with fluorescent detection (FLD), requiring both derivatization and complete baseline separation of all amino acids. Due to its high specificity and sensitivity, the use of UPLC-MS/MS eliminates the derivatization step and allows for overlapping amino acid retention times thereby shortening the analysis time. Furthermore, combining UPLC-MS/MS with stable isotope labeling (e.g., isobaric tag for relative and absolute quantitation, i.e., iTRAQ) of amino acids enables quantitation while maintaining sensitivity, selectivity and speed of analysis. In this study, we report combining UPLC-MS/MS analysis with iTRAQ labeling of amino acids resulting in the elution and quantitation of 44 amino acids within 5 min demonstrating the speed and convenience of this assay over established approaches. This chromatographic analysis time represented a 5-fold improvement over the conventional HPLC-MS/MS method developed in our laboratory. In addition, the UPLC-MS/MS method demonstrated improvements in both specificity and sensitivity without loss of precision. In comparing UPLC-MS/MS and HPLC-MS/MS results of 32 detected amino acids, only 2 amino acids exhibited imprecision (RSD) >15% using UPLC-MS/MS, while 9 amino acids exhibited RSD >15% using HPLC-MS/MS. Evaluating intra- and inter-assay precision over 3 days, the quantitation range for 32 detected amino acids in rat plasma was 0.90-497 μM, with overall mean intra-day precision of less than 15% and mean inter-day precision of 12%. This UPLC-MS/MS assay was successfully implemented for the quantitative analysis of amino acids in rat and mouse plasma, along with mouse urine and tissue samples, resulting in the following concentration ranges: 0.98-431 μM in mouse plasma for 32 detected amino acids; 0.62-443 μM in rat plasma for 32 detected amino acids; 0.44-8590μM in mouse liver for 33 detected amino acids; 0.61-1241

  20. Bioavailability of Oral Hydrocortisone Corrected for Binding Proteins and Measured by LC-MS/MS Using Serum Cortisol and Salivary Cortisone.

    PubMed

    Johnson, T N; Whitaker, M J; Keevil, B; Ross, R J

    2018-01-01

    The assessment absolute bioavailability of oral hydrocortisone is complicated by its saturable binding to cortisol binding globulin (CBG). Previous assessment of bioavailability used a cortisol radioimmunoassay which has cross reactivity with other steroids. Salivary cortisone is a measure of free cortisol and LC-MS/MS is the gold standard method for measuring steroids. We here report the absolute bioavailability of hydrocortisone calculated using serum cortisol and salivary cortisone measured by LC-MS/MS. 14 healthy male dexamethasone suppressed volunteers were administered 20 mg hydrocortisone either intravenously or orally by tablet. Samples of serum and saliva were taken and measured for cortisol and cortisone by LC-MS/MS. Serum cortisol was corrected for saturable binding using published data and pharmacokinetic parameters derived using the program WinNonlin. The mean (95% CI) bioavailability of oral hydrocortisone calculated from serum cortisol, unbound serum cortisol and salivary cortisone was 1.00 (0.89-1.14); 0.88 (0.75-1.05); and 0.93 (0.83-1.05), respectively. The data confirm that, after oral administration, hydrocortisone is completely absorbed. The data derived from serum cortisol corrected for protein binding, and that from salivary cortisone, are similar supporting the concept that salivary cortisone reflects serum free cortisol levels and that salivary cortisone can be used as a non-invasive method for measuring the pharmacokinetics of hydrocortisone.

  1. IDEOM: an Excel interface for analysis of LC-MS-based metabolomics data.

    PubMed

    Creek, Darren J; Jankevics, Andris; Burgess, Karl E V; Breitling, Rainer; Barrett, Michael P

    2012-04-01

    The application of emerging metabolomics technologies to the comprehensive investigation of cellular biochemistry has been limited by bottlenecks in data processing, particularly noise filtering and metabolite identification. IDEOM provides a user-friendly data processing application that automates filtering and identification of metabolite peaks, paying particular attention to common sources of noise and false identifications generated by liquid chromatography-mass spectrometry (LC-MS) platforms. Building on advanced processing tools such as mzMatch and XCMS, it allows users to run a comprehensive pipeline for data analysis and visualization from a graphical user interface within Microsoft Excel, a familiar program for most biological scientists. IDEOM is provided free of charge at http://mzmatch.sourceforge.net/ideom.html, as a macro-enabled spreadsheet (.xlsb). Implementation requires Microsoft Excel (2007 or later). R is also required for full functionality. michael.barrett@glasgow.ac.uk Supplementary data are available at Bioinformatics online.

  2. Improved LC-MS/MS method for the quantification of hepcidin-25 in clinical samples.

    PubMed

    Abbas, Ioana M; Hoffmann, Holger; Montes-Bayón, María; Weller, Michael G

    2018-06-01

    Mass spectrometry-based methods play a crucial role in the quantification of the main iron metabolism regulator hepcidin by singling out the bioactive 25-residue peptide from the other naturally occurring N-truncated isoforms (hepcidin-20, -22, -24), which seem to be inactive in iron homeostasis. However, several difficulties arise in the MS analysis of hepcidin due to the "sticky" character of the peptide and the lack of suitable standards. Here, we propose the use of amino- and fluoro-silanized autosampler vials to reduce hepcidin interaction to laboratory glassware surfaces after testing several types of vials for the preparation of stock solutions and serum samples for isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS). Furthermore, we have investigated two sample preparation strategies and two chromatographic separation conditions with the aim of developing a LC-MS/MS method for the sensitive and reliable quantification of hepcidin-25 in serum samples. A chromatographic separation based on usual acidic mobile phases was compared with a novel approach involving the separation of hepcidin-25 with solvents at high pH containing 0.1% of ammonia. Both methods were applied to clinical samples in an intra-laboratory comparison of two LC-MS/MS methods using the same hepcidin-25 calibrators with good correlation of the results. Finally, we recommend a LC-MS/MS-based quantification method with a dynamic range of 0.5-40 μg/L for the assessment of hepcidin-25 in human serum that uses TFA-based mobile phases and silanized glass vials. Graphical abstract Structure of hepcidin-25 (Protein Data Bank, PDB ID 2KEF).

  3. MASPECTRAS: a platform for management and analysis of proteomics LC-MS/MS data

    PubMed Central

    Hartler, Jürgen; Thallinger, Gerhard G; Stocker, Gernot; Sturn, Alexander; Burkard, Thomas R; Körner, Erik; Rader, Robert; Schmidt, Andreas; Mechtler, Karl; Trajanoski, Zlatko

    2007-01-01

    Background The advancements of proteomics technologies have led to a rapid increase in the number, size and rate at which datasets are generated. Managing and extracting valuable information from such datasets requires the use of data management platforms and computational approaches. Results We have developed the MAss SPECTRometry Analysis System (MASPECTRAS), a platform for management and analysis of proteomics LC-MS/MS data. MASPECTRAS is based on the Proteome Experimental Data Repository (PEDRo) relational database schema and follows the guidelines of the Proteomics Standards Initiative (PSI). Analysis modules include: 1) import and parsing of the results from the search engines SEQUEST, Mascot, Spectrum Mill, X! Tandem, and OMSSA; 2) peptide validation, 3) clustering of proteins based on Markov Clustering and multiple alignments; and 4) quantification using the Automated Statistical Analysis of Protein Abundance Ratios algorithm (ASAPRatio). The system provides customizable data retrieval and visualization tools, as well as export to PRoteomics IDEntifications public repository (PRIDE). MASPECTRAS is freely available at Conclusion Given the unique features and the flexibility due to the use of standard software technology, our platform represents significant advance and could be of great interest to the proteomics community. PMID:17567892

  4. Significantly decreased and more variable expression of major CYPs and UGTs in liver microsomes prepared from HBV-positive human hepatocellular carcinoma and matched pericarcinomatous tissues determined using an isotope label-free UPLC-MS/MS method.

    PubMed

    Yan, Tongmeng; Gao, Song; Peng, Xiaojuan; Shi, Jian; Xie, Cong; Li, Qiang; Lu, Linlin; Wang, Ying; Zhou, Fuyuan; Liu, Zhongqiu; Hu, Ming

    2015-03-01

    To determine the liver expression of cytochrome P450 (CYPs) and uridine 5'-diphosphate-glucuronosyltransferases (UGTs), the major phase I and II metabolism enzymes responsible for clearance and detoxification of drugs, xenobiotic and endogenous substances. A validated isotope label-free method was established for absolute and simultaneous quantification of 9 CYPs (1A2, 2A6, 2B6, 2C8, 2C9, 2C19, 2D, 2E1 and 3A4) and 5 UGTs (1A1, 1A4, 1A6, 1A9 and 2B7) in human liver microsomes using LC-MS/MS. The LC-MS/MS method displayed excellent dynamic range (at least 250-fold) and high sensitivity for each of the signature peptides with acceptable recovery, accuracy and precision. The protein expression profile of CYP and UGT isoforms were then determined in match microsomes samples prepared from patients with HBV-positive human hepatocellular carcinoma (HCC). In the tumor microsomes, the average absolute amounts of 8 major CYP isoforms (except CYP2C19) and 3 UGT isoforms (UGT1A1, UGT1A4 and UGT2B7) were decreased significantly (p < 0.05), whereas UGT1A6 and UGT1A9 levels were unchanged (p > 0.05). In addition, among isoforms with altered expression, 6 of 8 CYP isoforms and all three UGT isoforms were much more variable in tumor microsomes. Lastly, the importance of CYP3A4 was greatly diminished whereas the importance of UGT1A6 was enhanced in tumor microsomes. The use of an isotope label-free absolute quantification method for the simultaneous determination of 9 CYPs and 5 UGTs in human liver microsomes reveals that expression levels of CYPs and UGTs in human liver are severely impact by HCC, which could impact drug metabolism, disposition and pharmacotherapy.

  5. Protein profile in HBx transfected cells: a comparative iTRAQ-coupled 2D LC-MS/MS analysis.

    PubMed

    Feng, Huixing; Li, Xi; Niu, Dandan; Chen, Wei Ning

    2010-06-16

    The x protein of HBV (HBx) has been involved in the development of hepatocellular carcinoma (HCC), with a possible link to individual genotypes. Nevertheless, the underlying mechanism remains obscure. In this study, we aim to identify the HBx-induced protein profile in HepG2 cells by LC-MS/MS proteomics analysis. Our results indicated that proteins were differentially expressed in HepG2 cells transfected by HBx of various genotypes. Proteins associated with cytoskeleton were found to be either up-regulated (MACF1, HMGB1, Annexin A2) or down-regulated (Lamin A/C). These may in turn result in the decrease of focal adhesion and increase of cell migration in response to HBx. Levels of other cellular proteins with reported impact on the function of extracellular matrix (ECM) proteins and cell migration, including Ca(2+)-binding proteins (S100A11, S100A6, and S100A4) and proteasome protein (PSMA3), were affected by HBx. The differential protein profile identified in this study was also supported by our functional assay which indicated that cell migration was enhanced by HBx. Our preliminary study provided a new platform to establish a comprehensive cellular protein profile by LC-MS/MS proteomics analysis. Further downstream functional assays, including our reported cell migration assay, should provide new insights in the association between HCC and HBx. Copyright 2009 Elsevier B.V. All rights reserved.

  6. Simultaneous Release and Labeling of O- and N-Glycans Allowing for Rapid Glycomic Analysis by Online LC-UV-ESI-MS/MS.

    PubMed

    Wang, Chengjian; Lu, Yu; Han, Jianli; Jin, Wanjun; Li, Lingmei; Zhang, Ying; Song, Xuezheng; Huang, Linjuan; Wang, Zhongfu

    2018-05-24

    Most glycoproteins and biological protein samples undergo both O- and N-glycosylation, making characterization of their structures very complicated and time-consuming. Nevertheless, to fully understand the biological functions of glycosylation, both the glycosylation forms need to be analyzed. Herein we report a versatile, convenient one-pot method in which O- and N-glycans are simultaneously released from glycoproteins and chromogenically labeled in situ and thus available for further characterization. In this procedure, glycoproteins are incubated with 1-phenyl-3-methyl-5-pyrazolone (PMP) in aqueous ammonium hydroxide, making O-glycans released from protein backbones by β-elimination and N-glycans liberated by alkaline hydrolysis. The released glycans are promptly derivatized with PMP in situ by Knoevenagel condensation and Michael addition, with peeling degradation almost completely prevented. The recovered mixture of O- and N-glycans as bis-PMP derivatives features strong ultraviolet (UV) absorbing ability and hydrophobicity, allowing for high-resolution chromatographic separation and high-sensitivity spectrometric detection. Using this technique, O- and N-glycans were simultaneously prepared from some model glycoproteins and complex biological samples, without significant peeling, desialylation, deacetylation, desulfation or other side-reactions, and then comprehensively analyzed by online HILIC-UV-ESI-MS/MS and RP-HPLC-UV-ESI-MS/MS, with which some novel O- and N-glycan structures were first found. This method provides a simple, versatile strategy for high-throughput glycomics analysis.

  7. Data reduction of isotope-resolved LC-MS spectra.

    PubMed

    Du, Peicheng; Sudha, Rajagopalan; Prystowsky, Michael B; Angeletti, Ruth Hogue

    2007-06-01

    Data reduction of liquid chromatography-mass spectrometry (LC-MS) spectra can be a challenge due to the inherent complexity of biological samples, noise and non-flat baseline. We present a new algorithm, LCMS-2D, for reliable data reduction of LC-MS proteomics data. LCMS-2D can reliably reduce LC-MS spectra with multiple scans to a list of elution peaks, and subsequently to a list of peptide masses. It is capable of noise removal, and deconvoluting peaks that overlap in m/z, in retention time, or both, by using a novel iterative peak-picking step, a 'rescue' step, and a modified variable selection method. LCMS-2D performs well with three sets of annotated LC-MS spectra, yielding results that are better than those from PepList, msInspect and the vendor software BioAnalyst. The software LCMS-2D is available under the GNU general public license from http://www.bioc.aecom.yu.edu/labs/angellab/as a standalone C program running on LINUX.

  8. Power of Orbitrap-based LC-high resolution-MS/MS for comprehensive drug testing in urine with or without conjugate cleavage or using dried urine spots after on-spot cleavage in comparison to established LC-MSn or GC-MS procedures.

    PubMed

    Michely, Julian A; Meyer, Markus R; Maurer, Hans H

    2018-01-01

    Reliable, sensitive, and comprehensive urine screening procedures by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-mass spectrometry (LC-MS) with low or high resolution (HR) are of high importance for drug testing, adherence monitoring, or detection of toxic compounds. Besides conventional urine sampling, dried urine spots are of increasing interest. In the present study, the power of LC-HR-MS/MS was investigated for comprehensive drug testing in urine with or without conjugate cleavage or using dried urine spots after on-spot cleavage in comparison to established LC-MS n or GC-MS procedures. Authentic human urine samples (n = 103) were split in 4 parts. One aliquot was prepared by precipitation (UP), one by UP with conjugate cleavage (UglucP), one spot on filter paper cards and prepared by on-spot cleavage followed by liquid extraction (DUSglucE), and one worked-up by acid hydrolysis, liquid-liquid extraction, and acetylation for GC-MS analysis. The 3 series of LC-HR-MS/MS results were compared among themselves, to corresponding published LC-MS n data, and to screening results obtained by conventional GC-MS. The reference libraries used for the 3 techniques contained over 4500 spectra of parent compounds and their metabolites. The number of all detected hits (770 drug intakes) was set to 100%. The LC-HR-MS/MS approach detected 80% of the hits after UP, 89% after UglucP, and 77% after DUSglucE, which meant over one-third more hits in comparison to the corresponding published LC-MS n results with ≤49% detected hits. The GC-MS approach identified 56% of all detected hits. In conclusion, LC-HR-MS/MS provided the best screening results after conjugate cleavage and precipitation. Copyright © 2017 John Wiley & Sons, Ltd.

  9. ALLocator: an interactive web platform for the analysis of metabolomic LC-ESI-MS datasets, enabling semi-automated, user-revised compound annotation and mass isotopomer ratio analysis.

    PubMed

    Kessler, Nikolas; Walter, Frederik; Persicke, Marcus; Albaum, Stefan P; Kalinowski, Jörn; Goesmann, Alexander; Niehaus, Karsten; Nattkemper, Tim W

    2014-01-01

    Adduct formation, fragmentation events and matrix effects impose special challenges to the identification and quantitation of metabolites in LC-ESI-MS datasets. An important step in compound identification is the deconvolution of mass signals. During this processing step, peaks representing adducts, fragments, and isotopologues of the same analyte are allocated to a distinct group, in order to separate peaks from coeluting compounds. From these peak groups, neutral masses and pseudo spectra are derived and used for metabolite identification via mass decomposition and database matching. Quantitation of metabolites is hampered by matrix effects and nonlinear responses in LC-ESI-MS measurements. A common approach to correct for these effects is the addition of a U-13C-labeled internal standard and the calculation of mass isotopomer ratios for each metabolite. Here we present a new web-platform for the analysis of LC-ESI-MS experiments. ALLocator covers the workflow from raw data processing to metabolite identification and mass isotopomer ratio analysis. The integrated processing pipeline for spectra deconvolution "ALLocatorSD" generates pseudo spectra and automatically identifies peaks emerging from the U-13C-labeled internal standard. Information from the latter improves mass decomposition and annotation of neutral losses. ALLocator provides an interactive and dynamic interface to explore and enhance the results in depth. Pseudo spectra of identified metabolites can be stored in user- and method-specific reference lists that can be applied on succeeding datasets. The potential of the software is exemplified in an experiment, in which abundance fold-changes of metabolites of the l-arginine biosynthesis in C. glutamicum type strain ATCC 13032 and l-arginine producing strain ATCC 21831 are compared. Furthermore, the capability for detection and annotation of uncommon large neutral losses is shown by the identification of (γ-)glutamyl dipeptides in the same strains

  10. LC-MS/MS and GC-MS methods in propofol detection: Evaluation of the two analytical procedures.

    PubMed

    Vaiano, Fabio; Serpelloni, Giovanni; Focardi, Martina; Fioravanti, Alessia; Mari, Francesco; Bertol, Elisabetta

    2015-11-01

    Propofol is a short-acting hypnotic agent that is commonly used to induce and maintain anesthesia. Propofol abuse and its involvement in suicide deaths have increased in recent years, especially among healthcare personnel. An example is the suicide of a 61-year-old nurse found with a propofol drip in his left arm. We describe the postmortem concentration of propofol in various tissues (femoral and cardiac blood, bile, urine, brain, and liver) and in the drip. The toxicological analyses were performed through two analytical methods, differing in derivatization reaction and in instrumentation: silylation for gas chromatograph-mass spectrometer (GC-MS), as routinely performed in our laboratory for this kind of analyses (lower limits of quantification-LLOQ-in urine and blood: 0.3 and 5ng/ml); for liquid chromatograph-tandem mass spectrometer (LC-MS/MS) an innovative azo-coupling derivatization (LLOQ: 0.0004 and 0.1ng/ml). This latter produces an azo-derivative (molecular composition: C18H22ON2; molecular weight: 282Da) highly ionizable in electro-spray ion source, both in negative and positive ionizations. These two methods were compared to evaluate the effectiveness of this new LC-MS/MS analysis. An acidic hydrolysis (HCl 6N, 100°C, and 1h) was performed for the biological samples (1ml or 1g) irrespective of the analytical method applied. The drip content was extracted adding phosphate buffer (pH 8) and a dichloromethane/ethylacetate 8:2 (v:v) mixture. Derivatization steps were: silylation with N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA)+tetramethylammonium hydroxide (TMAH) for GC-MS; regarding LC-MS/MS, azo-coupling reaction with the aryl-diazonium salt (0-5°C, and 30min). The analyses were achieved in selected-ion monitoring for GC-MS (m/z, 235,250,73 propofol"; m/z, 252,267,27 propofol-d17) and in multiple reaction monitoring ([M-H](-): m/z 283→241,77, azo-propofol; m/z 299→251,77, azo-propofol-d17) for LC-MS/MS. Autopsy showed no significant findings

  11. Radical scavenging activity and LC-MS metabolic profiling of petals, stamens, and flowers of Crocus sativus L.

    PubMed

    Montoro, Paola; Maldini, Mariateresa; Luciani, Leonilda; Tuberoso, Carlo I G; Congiu, Francesca; Pizza, Cosimo

    2012-08-01

    Radical scavenging activities of Crocus sativus petals, stamens and entire flowers, which are waste products in the production of the spice saffron, by employing ABTS radical scavenging method, were determined. At the same time, the metabolic profiles of different extract (obtained by petals, stamens and flowers) were obtained by LC-ESI-IT MS (liquid chromatography coupled with electrospray mass spectrometry equipped with Ion Trap analyser). LC-ESI-MS is a techniques largely used nowadays for qualitative fingerprint of herbal extracts and particularly for phenolic compounds. To compare the different extracts under an analytical point of view a specific method for qualitative LC-MS analysis was developed. The high variety of glycosylated flavonoids found in the metabolic profiles could give value to C. sativus petals, stamens and entire flowers. Waste products obtained during saffron production, could represent an interesting source of phenolic compounds, with respect to the high variety of compounds and their free radical scavenging activity. © 2012 Institute of Food Technologists®

  12. Targeted and non-targeted detection of lemon juice adulteration by LC-MS and chemometrics.

    PubMed

    Wang, Zhengfang; Jablonski, Joseph E

    2016-01-01

    Economically motivated adulteration (EMA) of lemon juice was detected by LC-MS and principal component analysis (PCA). Twenty-two batches of freshly squeezed lemon juice were adulterated by adding an aqueous solution containing 5% citric acid and 6% sucrose to pure lemon juice to obtain 30%, 60% and 100% lemon juice samples. Their total titratable acidities, °Brix and pH values were measured, and then all the lemon juice samples were subject to LC-MS analysis. Concentrations of hesperidin and eriocitrin, major phenolic components of lemon juice, were quantified. The PCA score plots for LC-MS datasets were used to preview the classification of pure and adulterated lemon juice samples. Results showed a large inherent variability in the chemical properties among 22 batches of 100% lemon juice samples. Measurement or quantitation of one or several chemical properties (targeted detection) was not effective in detecting lemon juice adulteration. However, by using the LC-MS datasets, including both chromatographic and mass spectrometric information, 100% lemon juice samples were successfully differentiated from adulterated samples containing 30% lemon juice in the PCA score plot. LC-MS coupled with chemometric analysis can be a complement to existing methods for detecting juice adulteration.

  13. A multicenter study benchmarks software tools for label-free proteome quantification.

    PubMed

    Navarro, Pedro; Kuharev, Jörg; Gillet, Ludovic C; Bernhardt, Oliver M; MacLean, Brendan; Röst, Hannes L; Tate, Stephen A; Tsou, Chih-Chiang; Reiter, Lukas; Distler, Ute; Rosenberger, George; Perez-Riverol, Yasset; Nesvizhskii, Alexey I; Aebersold, Ruedi; Tenzer, Stefan

    2016-11-01

    Consistent and accurate quantification of proteins by mass spectrometry (MS)-based proteomics depends on the performance of instruments, acquisition methods and data analysis software. In collaboration with the software developers, we evaluated OpenSWATH, SWATH 2.0, Skyline, Spectronaut and DIA-Umpire, five of the most widely used software methods for processing data from sequential window acquisition of all theoretical fragment-ion spectra (SWATH)-MS, which uses data-independent acquisition (DIA) for label-free protein quantification. We analyzed high-complexity test data sets from hybrid proteome samples of defined quantitative composition acquired on two different MS instruments using different SWATH isolation-window setups. For consistent evaluation, we developed LFQbench, an R package, to calculate metrics of precision and accuracy in label-free quantitative MS and report the identification performance, robustness and specificity of each software tool. Our reference data sets enabled developers to improve their software tools. After optimization, all tools provided highly convergent identification and reliable quantification performance, underscoring their robustness for label-free quantitative proteomics.

  14. Development and Bioanalytical Validation of a Liquid Chromatographic-Tandem Mass Spectrometric (LC-MS/MS) Method for the Quantification of the CCR5 Antagonist Maraviroc in Human Plasma

    PubMed Central

    Emory, Joshua F.; Seserko, Lauren A.; Marzinke, Mark A.

    2014-01-01

    Background Maraviroc is a CCR5 antagonist that has been utilized as a viral entry inhibitor in the management of HIV-1. Current clinical trials are pursuing maraviroc drug efficacy in both oral and topical formulations. Therefore, in order to fully understand drug pharmacokinetics, a sensitive method is required to quantify plasma drug concentrations. Methods Maraviroc-spiked plasma was combined with acetonitrile containing an isotopically-labeled internal standard, and following protein precipitation, samples were evaporated to dryness and reconstituted for liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis. Chromatographic separation was achieved on a Waters BEH C8, 50 × 2.1 mm UPLC column, with a 1.7 μm particle size and the eluent was analyzed using an API 4000 mass analyzer in selected reaction monitoring mode. The method was validated as per FDA Bioanalytical Method Validation guidelines. Results The analytical measuring range of the LC-MS/MS method is 0.5-1000 ng/ml. Calibration curves were generated using weighted 1/x2 quadratic regression. Inter-and intra-assay precision was ≤ 5.38% and ≤ 5.98%, respectively; inter-and intra-assay accuracy (%DEV) was ≤ 10.2% and ≤ 8.44%, respectively. Additional studies illustrated similar matrix effects between maraviroc and its internal standard, and that maraviroc is stable under a variety of conditions. Method comparison studies with a reference LC-MS/MS method show a slope of 0.948 with a Spearman coefficient of 0.98. Conclusions Based on the validation metrics, we have generated a sensitive and automated LC-MS/MS method for maraviroc quantification in human plasma. PMID:24561264

  15. Label-free proteomic analysis of environmental acidification-influenced Streptococcus pyogenes secretome reveals a novel acid-induced protein histidine triad protein A (HtpA) involved in necrotizing fasciitis.

    PubMed

    Wen, Yao-Tseng; Wang, Jie-Siou; Tsai, Shu-Han; Chuan, Chiang-Ni; Wu, Jiunn-Jong; Liao, Pao-Chi

    2014-09-23

    Streptococcus pyogenes is responsible for various diseases. During infection, bacteria must adapt to adverse environments, such as the acidic environment. Acidic stimuli may stimulate S. pyogenes to invade into deeper tissue. However, how this acidic stimulus causes S. pyogenes to manipulate its secretome for facilitating invasion remains unclear. The dynamic label-free LC-MS/MS profiling identified 97 proteins, which are influenced by environmental acidification. Among these, 33 (34%) of the identified proteins were predicted to be extracellular proteins. Interestingly, classical secretory proteins comprise approximately 90% of protein abundance of the secretome in acidic condition at the stationary phase. One acid-induced secreted protein, HtpA, was selected to investigate its role in invasive infection. The mouse infected by the htpA deficient mutant showed lower virulence and smaller lesion area than the wild-type strain. The mutant strain was more efficiently cleared at infected skin than the wild-type strain. Besides, the relative phagocytosis resistance is lower in the mutant strain than in the wild-type strain. These data indicate that a novel acid-induced virulence factor, HtpA, which improves anti-phagocytosis ability for causing necrotizing fasciitis. Our investigation provides vital information for documenting the broad influences and mechanisms underlying the invasive behavior of S. pyogenes in an acidified environment. The acidified infected environment may facilitate S. pyogenes invasion from the mucosa to the deeper subepithelial tissue. The acid stimuli have been considered to affect the complex regulatory network of S. pyogenes for causing severe infections. Many of secreted virulence factors influenced by acidified environment may also play a crucial role in pathogenesis of invasive disease. To investigate temporal secretome changes under acidic environment, a comparative secretomics approach using label-free LC-MS/MS was undertaken to analyze

  16. Coupling liquid chromatography/mass spectrometry detection with microfluidic droplet array for label-free enzyme inhibition assay.

    PubMed

    Wang, Xiu-Li; Zhu, Ying; Fang, Qun

    2014-01-07

    In this work, the combination of droplet-based microfluidics with liquid chromatography/mass spectrometry (LC/MS) was achieved, for providing a fast separation and high-information-content detection method for the analysis of nanoliter-scale droplets with complex compositions. A novel interface method was developed using an oil-covered droplet array chip to couple with an LC/MS system via a capillary sampling probe and a 4 nL injection valve without the need of a droplet extraction device. The present system can perform multistep operations including parallel enzyme inhibition reactions in nanoliter droplets, 4 nL sample injection, fast separation with capillary LC, and label-free detection with ESI-MS, and has significant flexibility in the accurate addressing and sampling of droplets of interest on demand. The system performance was evaluated using angiotensin I and angiotensin II as model samples, and the repeatabilities of peak area for angiotensin I and angiotensin II were 2.7% and 7.5% (RSD, n = 4), respectively. The present system was further applied to the screening for inhibitors of cytochrome P450 (CYP1A2) and measurement of the IC50 value of the inhibitor. The sample consumption for each droplet assay was 100 nL, which is reduced 10-100 times compared with conventional 384-multi-well plate systems usually used in high-throughput drug screening.

  17. Determination of acrylamide in processed foods by LC/MS using column switching.

    PubMed

    Takatsuki, Satoshi; Nemoto, Satoru; Sasaki, Kumiko; Maitani, Tamio

    2003-04-01

    An LC/MS method was developed for the determination of acrylamide (AA) in processed or cooked foods. AA was extracted with a mixture of water and acetone from homogenized food samples after the addition of 13C-labeled acrylamide (AA-1-(13)C) as an internal standard. The extract was concentrated, washed with dichloromethane for defatting, and cleaned up on Bond Elut C18, PSA and ACCUCAT cartridge-columns, and then AA was determined by LC/MS in the selected ion recording (SIR) mode. For the LC/MS analysis, four LC columns were connected in-line and the flow of the mobile phase was switched according to a time-program. Monitoring ions for AA were m/z 72 and 55, and those for AA-1-(13)C were m/z 73 and 56. AA and AA-1-(13)C were determined without interference from the matrices in all samples. The recoveries of AA from potato chips, corn snack, pretzel and roasted tea spiked at the level of 500 ng/g of AA were 99.5-101.0% with standard deviations (SD) in the range from 0.3 to 1.6%. The limits of detection and quantification of the developed method were 9 and 30 ng/g for AA in samples, respectively. The method was applied to the analysis of AA in various processed or cooked food samples purchased from retail markets. High levels of AA were found in potato chips and French-fried potato (467-3,544 ng/g). Fried and sugar-coated dough cakes (karinto) contained 374 and 1,895 ng/g. Corn snacks contained 117-535 ng/g of AA. Roasted foods (such as roasted sesame seed, roasted barley (mugi-cha), roasted tea (hoji-cha), coffee beans and curry powder) contained 116-567 ng/g of AA. Foods made from fish, egg and meat contained lower levels of AA than the plant-based foods. Foods containing much water showed a tendency to have low levels of AA compared with dry foods. The proposed method was applicable to the analysis of AA in variety of processed foods.

  18. Integrated LC-MS/MS Analytical Systems and Physical Inspection for the Analysis of a Botanical Herbal Preparation.

    PubMed

    Lai, Kuan-Ming; Cheng, Yung-Yi; Tsai, Tung-Hu

    2015-06-09

    The herbal decoction process is generally inconvenient and unpleasant. To avoid using herbal medicine decoctions, various high-quality industrial and pharmaceutical herbal decoction products have been used in clinical applications for more than ten years in Taiwan. However, the consistency and standardization of the quality of these herbal medicines are goals that remain to be achieved. The aim of study was to develop a validated liquid chromatography-tandem electrospray ionization mass spectrometry (LC-MS/MS) method to determine the biomarkers astragaloside I, astragaloside IV, formononetin, cinnamic acid, paeoniflorin and gingerol in the herbal preparation known as Huangqi-Guizhi-Wuwu (HGW). To investigate the physical quality of HGW, methods such as scanning electron microscopy, light microscopy with Congo red and potassium iodine staining, solubility measurements, swelling power tests, and crude fiber analysis were used to identify additives in commercial pharmaceutical products. The optimal LC-MS/MS multiple reaction-monitoring system included a gradient program using 5 mM ammonium acetate buffer with 0.05% formic acid/methanol. The results demonstrate deviations in biomarker content across different brands. In addition to the herbal extract, starch and excipients in the pharmaceutical granule, and crushed crude herb powder was added to the pharmaceutical products to increase their herbal ingredient content. In conclusion, a rigorous examination should be performed to certify the quality of the herbal products.

  19. Multiplexed LC-MS/MS analysis of horse plasma proteins to study doping in sport.

    PubMed

    Barton, Chris; Beck, Paul; Kay, Richard; Teale, Phil; Roberts, Jane

    2009-06-01

    The development of protein biomarkers for the indirect detection of doping in horse is a potential solution to doping threats such as gene and protein doping. A method for biomarker candidate discovery in horse plasma is presented using targeted analysis of proteotypic peptides from horse proteins. These peptides were first identified in a novel list of the abundant proteins in horse plasma. To monitor these peptides, an LC-MS/MS method using multiple reaction monitoring was developed to study the quantity of 49 proteins in horse plasma in a single run. The method was optimised and validated, and then applied to a population of race-horses to study protein variance within a population. The method was finally applied to longitudinal time courses of horse plasma collected after administration of an anabolic steroid to demonstrate utility for hypothesis-driven discovery of doping biomarker candidates.

  20. A Collaborative Evaluation of LC-MS/MS Based Methods for BMAA Analysis: Soluble Bound BMAA Found to Be an Important Fraction

    PubMed Central

    Faassen, Elisabeth J.; Antoniou, Maria G.; Beekman-Lukassen, Wendy; Blahova, Lucie; Chernova, Ekaterina; Christophoridis, Christophoros; Combes, Audrey; Edwards, Christine; Fastner, Jutta; Harmsen, Joop; Hiskia, Anastasia; Ilag, Leopold L.; Kaloudis, Triantafyllos; Lopicic, Srdjan; Lürling, Miquel; Mazur-Marzec, Hanna; Meriluoto, Jussi; Porojan, Cristina; Viner-Mozzini, Yehudit; Zguna, Nadezda

    2016-01-01

    Exposure to β-N-methylamino-l-alanine (BMAA) might be linked to the incidence of amyotrophic lateral sclerosis, Alzheimer’s disease and Parkinson’s disease. Analytical chemistry plays a crucial role in determining human BMAA exposure and the associated health risk, but the performance of various analytical methods currently employed is rarely compared. A CYANOCOST initiated workshop was organized aimed at training scientists in BMAA analysis, creating mutual understanding and paving the way towards interlaboratory comparison exercises. During this workshop, we tested different methods (extraction followed by derivatization and liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) analysis, or directly followed by LC-MS/MS analysis) for trueness and intermediate precision. We adapted three workup methods for the underivatized analysis of animal, brain and cyanobacterial samples. Based on recovery of the internal standard D3BMAA, the underivatized methods were accurate (mean recovery 80%) and precise (mean relative standard deviation 10%), except for the cyanobacterium Leptolyngbya. However, total BMAA concentrations in the positive controls (cycad seeds) showed higher variation (relative standard deviation 21%–32%), implying that D3BMAA was not a good indicator for the release of BMAA from bound forms. Significant losses occurred during workup for the derivatized method, resulting in low recovery (<10%). Most BMAA was found in a trichloroacetic acid soluble, bound form and we recommend including this fraction during analysis. PMID:26938542

  1. A Collaborative Evaluation of LC-MS/MS Based Methods for BMAA Analysis: Soluble Bound BMAA Found to Be an Important Fraction.

    PubMed

    Faassen, Elisabeth J; Antoniou, Maria G; Beekman-Lukassen, Wendy; Blahova, Lucie; Chernova, Ekaterina; Christophoridis, Christophoros; Combes, Audrey; Edwards, Christine; Fastner, Jutta; Harmsen, Joop; Hiskia, Anastasia; Ilag, Leopold L; Kaloudis, Triantafyllos; Lopicic, Srdjan; Lürling, Miquel; Mazur-Marzec, Hanna; Meriluoto, Jussi; Porojan, Cristina; Viner-Mozzini, Yehudit; Zguna, Nadezda

    2016-02-29

    Exposure to β-N-methylamino-l-alanine (BMAA) might be linked to the incidence of amyotrophic lateral sclerosis, Alzheimer's disease and Parkinson's disease. Analytical chemistry plays a crucial role in determining human BMAA exposure and the associated health risk, but the performance of various analytical methods currently employed is rarely compared. A CYANOCOST initiated workshop was organized aimed at training scientists in BMAA analysis, creating mutual understanding and paving the way towards interlaboratory comparison exercises. During this workshop, we tested different methods (extraction followed by derivatization and liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) analysis, or directly followed by LC-MS/MS analysis) for trueness and intermediate precision. We adapted three workup methods for the underivatized analysis of animal, brain and cyanobacterial samples. Based on recovery of the internal standard D₃BMAA, the underivatized methods were accurate (mean recovery 80%) and precise (mean relative standard deviation 10%), except for the cyanobacterium Leptolyngbya. However, total BMAA concentrations in the positive controls (cycad seeds) showed higher variation (relative standard deviation 21%-32%), implying that D₃BMAA was not a good indicator for the release of BMAA from bound forms. Significant losses occurred during workup for the derivatized method, resulting in low recovery (<10%). Most BMAA was found in a trichloroacetic acid soluble, bound form and we recommend including this fraction during analysis.

  2. A high-throughput urinalysis of abused drugs based on a SPE-LC-MS/MS method coupled with an in-house developed post-analysis data treatment system.

    PubMed

    Cheng, Wing-Chi; Yau, Tsan-Sang; Wong, Ming-Kei; Chan, Lai-Ping; Mok, Vincent King-Kuen

    2006-10-16

    A rapid urinalysis system based on SPE-LC-MS/MS with an in-house post-analysis data management system has been developed for the simultaneous identification and semi-quantitation of opiates (morphine, codeine), methadone, amphetamines (amphetamine, methylamphetamine (MA), 3,4-methylenedioxyamphetamine (MDA) and 3,4-methylenedioxymethamphetamine (MDMA)), 11-benzodiazepines or their metabolites and ketamine. The urine samples are subjected to automated solid phase extraction prior to analysis by LC-MS (Finnigan Surveyor LC connected to a Finnigan LCQ Advantage) fitted with an Alltech Rocket Platinum EPS C-18 column. With a single point calibration at the cut-off concentration for each analyte, simultaneous identification and semi-quantitation for the above mentioned drugs can be achieved in a 10 min run per urine sample. A computer macro-program package was developed to automatically retrieve appropriate data from the analytical data files, compare results with preset values (such as cut-off concentrations, MS matching scores) of each drug being analyzed and generate user-defined Excel reports to indicate all positive and negative results in batch-wise manner for ease of checking. The final analytical results are automatically copied into an Access database for report generation purposes. Through the use of automation in sample preparation, simultaneous identification and semi-quantitation by LC-MS/MS and a tailored made post-analysis data management system, this new urinalysis system significantly improves the quality of results, reduces the post-data treatment time, error due to data transfer and is suitable for high-throughput laboratory in batch-wise operation.

  3. Chromatographic behavior of co-eluted plasma compounds and effect on screening of drugs by APCI-LC-MS(/MS): Applications to selected cardiovascular drugs.

    PubMed

    Tahboub, Yahya R

    2014-12-01

    Chromatographic behavior of co-eluted compounds from un-extracted drug-free plasma samples was studied by LC-MS and LC-MS/MS with positive APCI. Under soft gradient, total ion chromatogram (TIC) consisted of two major peaks separated by a constant lower intensity region. Early peak (0.15-0.4 min) belongs to polar plasma compounds and consisted of smaller mass ions ( m / z <250); late peak (3.6-4.6 min) belongs to thermally unstable phospholipids and consisted of fragments with m / z <300. Late peak is more sensitive to variations in chromatographic and MS parameters. Screening of most targeted cardiovascular drugs at levels lower than 50 ng/mL has been possible by LC-MS for drugs with retention factors larger than three. Matrix effects and recovery, at 20 and 200 ng/mL, were evaluated for spiked plasma samples with 15 cardiovascular drugs, by MRM-LC-MS/MS. Average recoveries were above 90% and matrix effects expressed as percent matrix factor (% MF) were above 100%, indicating enhancement character for APCI. Large uncertainties were significant for drugs with smaller masses ( m / z <250) and retention factors lower than two.

  4. A Protein Preparation Method for the High-throughput Identification of Proteins Interacting with a Nuclear Cofactor Using LC-MS/MS Analysis.

    PubMed

    Tsuchiya, Megumi; Karim, M Rezaul; Matsumoto, Taro; Ogawa, Hidesato; Taniguchi, Hiroaki

    2017-01-24

    Transcriptional coregulators are vital to the efficient transcriptional regulation of nuclear chromatin structure. Coregulators play a variety of roles in regulating transcription. These include the direct interaction with transcription factors, the covalent modification of histones and other proteins, and the occasional chromatin conformation alteration. Accordingly, establishing relatively quick methods for identifying proteins that interact within this network is crucial to enhancing our understanding of the underlying regulatory mechanisms. LC-MS/MS-mediated protein binding partner identification is a validated technique used to analyze protein-protein interactions. By immunoprecipitating a previously-identified member of a protein complex with an antibody (occasionally with an antibody for a tagged protein), it is possible to identify its unknown protein interactions via mass spectrometry analysis. Here, we present a method of protein preparation for the LC-MS/MS-mediated high-throughput identification of protein interactions involving nuclear cofactors and their binding partners. This method allows for a better understanding of the transcriptional regulatory mechanisms of the targeted nuclear factors.

  5. Determination of nicotianamine in soy sauce and other plant-based foods by LC-MS/MS.

    PubMed

    Yamaguchi, Hitomi; Uchida, Riichiro

    2012-10-10

    Nicotianamine is a nonproteinogenic amino acid, known to be an important metal chelator in plants. Recently, the antihypertensive effect of nicotianamine was discovered. In this study, a simple method to determine nicotianamine was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) with a multimode ODS column. This method does not need derivatizing or ion-pairing reagents to retain nicotianamine, which is known for its poor retention on reversed-phase columns because of its high polarity. Moreover, this method showed a sufficient limit of detection (0.5 ng/mL), so it was found to be suitable for the analysis of nicotianamine in soy sauce and other foods, without cleanup. To subtract the matrix effect during LC-MS/MS analysis, a standard addition method was used. The levels of nicotianamine in soy sauce ranged from <0.25 to 71 μg/g. Nicotianamine was also determined in other foods, including soy milk, vegetable juice, fruit juice, and bottled tea.

  6. Platform-independent and label-free quantitation of proteomic data using MS1 extracted ion chromatograms in skyline: application to protein acetylation and phosphorylation.

    PubMed

    Schilling, Birgit; Rardin, Matthew J; MacLean, Brendan X; Zawadzka, Anna M; Frewen, Barbara E; Cusack, Michael P; Sorensen, Dylan J; Bereman, Michael S; Jing, Enxuan; Wu, Christine C; Verdin, Eric; Kahn, C Ronald; Maccoss, Michael J; Gibson, Bradford W

    2012-05-01

    Despite advances in metabolic and postmetabolic labeling methods for quantitative proteomics, there remains a need for improved label-free approaches. This need is particularly pressing for workflows that incorporate affinity enrichment at the peptide level, where isobaric chemical labels such as isobaric tags for relative and absolute quantitation and tandem mass tags may prove problematic or where stable isotope labeling with amino acids in cell culture labeling cannot be readily applied. Skyline is a freely available, open source software tool for quantitative data processing and proteomic analysis. We expanded the capabilities of Skyline to process ion intensity chromatograms of peptide analytes from full scan mass spectral data (MS1) acquired during HPLC MS/MS proteomic experiments. Moreover, unlike existing programs, Skyline MS1 filtering can be used with mass spectrometers from four major vendors, which allows results to be compared directly across laboratories. The new quantitative and graphical tools now available in Skyline specifically support interrogation of multiple acquisitions for MS1 filtering, including visual inspection of peak picking and both automated and manual integration, key features often lacking in existing software. In addition, Skyline MS1 filtering displays retention time indicators from underlying MS/MS data contained within the spectral library to ensure proper peak selection. The modular structure of Skyline also provides well defined, customizable data reports and thus allows users to directly connect to existing statistical programs for post hoc data analysis. To demonstrate the utility of the MS1 filtering approach, we have carried out experiments on several MS platforms and have specifically examined the performance of this method to quantify two important post-translational modifications: acetylation and phosphorylation, in peptide-centric affinity workflows of increasing complexity using mouse and human models.

  7. Profiling intact steroid sulfates and unconjugated steroids in biological fluids by liquid chromatography-tandem mass spectrometry (LC-MS-MS).

    PubMed

    Galuska, Christina E; Hartmann, Michaela F; Sánchez-Guijo, Alberto; Bakhaus, Katharina; Geyer, Joachim; Schuler, Gerhard; Zimmer, Klaus-Peter; Wudy, Stefan A

    2013-07-07

    Within the combined DFG research project "Sulfated Steroids in Reproduction" an analytical method was needed for determining sulfated and unconjugated steroids with highest specificity out of different biological matrices such as aqueous solution, cell lysate and serum. With regard to this analytical challenge, LC-MS-MS presents the technique of choice because it permits (1) analysis of the intact steroid conjugate, (2) allows for simultaneous determination of multiple analytes (profiling, targeted metabolomics approach) and (3) is independent of phenomena such as cross-reactivity. Sample work up consisted of incubation of sample with internal standards (deuterium labeled steroids) followed by solid phase extraction. Only serum samples required a protein precipitation step prior to solid phase extraction. The extract was divided in two parts: six steroid sulfates (E1S, E2S, AS, 16-OH-DHEAS, PREGS, DHEAS) were analyzed by C18aQ-ESI-MS-MS in negative ion mode and eleven unconjugated steroids (E3, 16-OH-DHEA, E1, E2, (4)A, DHEA, T, 17-OH-PREG, Prog, An, PREG) were analyzed by C18-APCI-MS-MS in positive ion mode. For steroid sulfates, we found high sensitivities with LoQ values ranging from 0.08 to 1 ng mL(-1). Unconjugated steroids showed LoQ values between 0.5 and 10 ng mL(-1). Calibration plots showed excellent linearity. Mean intra- and inter-assay CVs were 2.4% for steroid sulfates and 6.4% for unconjugated steroids. Accuracy - determined in a two-level spike experiment - showed mean relative errors of 5.9% for steroid sulfates and 6.1% for unconjugated steroids. In summary, we describe a novel LC-MS-MS procedure capable of profiling six steroid sulfates and eleven unconjugated steroids from various biological matrices.

  8. Online immunoaffinity LC/MS/MS. A general method to increase sensitivity and specificity: How do you do it and what do you need?

    PubMed

    Dufield, Dawn R; Radabaugh, Melissa R

    2012-02-01

    There is an increased emphasis on hyphenated techniques such as immunoaffinity LC/MS/MS (IA-LC/MS/MS) or IA-LC/MRM. These techniques offer competitive advantages with respect to sensitivity and selectivity over traditional LC/MS and are complementary to ligand binding assays (LBA) or ELISA's. However, these techniques are not entirely straightforward and there are several tips and tricks to routine sample analysis. We describe here our methods and procedures for how to perform online IA-LC/MS/MS including a detailed protocol for the preparation of antibody (Ab) enrichment columns. We have included sample trapping and Ab methods. Furthermore, we highlight tips, tricks, minimal and optimal approaches. This technology has been shown to be viable for several applications, species and fluids from small molecules to proteins and biomarkers to PK assays. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. SimExTargId: A comprehensive package for real-time LC-MS data acquisition and analysis.

    PubMed

    Edmands, William M B; Hayes, Josie; Rappaport, Stephen M

    2018-05-22

    Liquid chromatography mass spectrometry (LC-MS) is the favored method for untargeted metabolomic analysis of small molecules in biofluids. Here we present SimExTargId, an open-source R package for autonomous analysis of metabolomic data and real-time observation of experimental runs. This simultaneous, fully automated and multi-threaded (optional) package is a wrapper for vendor-independent format conversion (ProteoWizard), xcms- and CAMERA- based peak-picking, MetMSLine-based pre-processing and covariate-based statistical analysis. Users are notified of detrimental instrument drift or errors by email. Also included are two shiny applications, targetId for real-time MS2 target identification, and peakMonitor to monitor targeted metabolites. SimExTargId is publicly available under GNU LGPL v3.0 license at https://github.com/JosieLHayes/simExTargId, which includes a vignette with example data. SimExTargId should be installed on a dedicated data-processing workstation or server that is networked to the LC-MS platform to facilitate MS1 profiling of metabolomic data. josie.hayes@berkeley.edu. Supplementary data are available at Bioinformatics online.

  10. LC-MS/MS quantification of next-generation biotherapeutics: a case study for an IgE binding Nanobody in cynomolgus monkey plasma.

    PubMed

    Sandra, Koen; Mortier, Kjell; Jorge, Lucie; Perez, Luis C; Sandra, Pat; Priem, Sofie; Poelmans, Sofie; Bouche, Marie-Paule

    2014-05-01

    Nanobodies(®) are therapeutic proteins derived from the smallest functional fragments of heavy chain-only antibodies. The development and validation of an LC-MS/MS-based method for the quantification of an IgE binding Nanobody in cynomolgus monkey plasma is presented. Nanobody quantification was performed making use of a proteotypic tryptic peptide chromatographically enriched prior to LC-MS/MS analysis. The validated LLOQ at 36 ng/ml was measured with an intra- and inter-assay precision and accuracy <20%. The required sensitivity could be obtained based on the selectivity of 2D LC combined with MS/MS. No analyte specific tools for affinity purification were used. Plasma samples originating from a PK/PD study were analyzed and compared with the results obtained with a traditional ligand-binding assay. Excellent correlations between the two techniques were obtained, and similar PK parameters were estimated. A 2D LC-MS/MS method was successfully developed and validated for the quantification of a next generation biotherapeutic.

  11. Rapid Verification of Candidate Serological Biomarkers Using Gel-based, Label-free Multiple Reaction Monitoring

    PubMed Central

    Tang, Hsin-Yao; Beer, Lynn A.; Barnhart, Kurt T.; Speicher, David W.

    2011-01-01

    Stable isotope dilution-multiple reaction monitoring-mass spectrometry (SID-MRM-MS) has emerged as a promising platform for verification of serological candidate biomarkers. However, cost and time needed to synthesize and evaluate stable isotope peptides, optimize spike-in assays, and generate standard curves, quickly becomes unattractive when testing many candidate biomarkers. In this study, we demonstrate that label-free multiplexed MRM-MS coupled with major protein depletion and 1-D gel separation is a time-efficient, cost-effective initial biomarker verification strategy requiring less than 100 μl serum. Furthermore, SDS gel fractionation can resolve different molecular weight forms of targeted proteins with potential diagnostic value. Because fractionation is at the protein level, consistency of peptide quantitation profiles across fractions permits rapid detection of quantitation problems for specific peptides from a given protein. Despite the lack of internal standards, the entire workflow can be highly reproducible, and long-term reproducibility of relative protein abundance can be obtained using different mass spectrometers and LC methods with external reference standards. Quantitation down to ~200 pg/mL could be achieved using this workflow. Hence, the label-free GeLC-MRM workflow enables rapid, sensitive, and economical initial screening of large numbers of candidate biomarkers prior to setting up SID-MRM assays or immunoassays for the most promising candidate biomarkers. PMID:21726088

  12. Rapid verification of candidate serological biomarkers using gel-based, label-free multiple reaction monitoring.

    PubMed

    Tang, Hsin-Yao; Beer, Lynn A; Barnhart, Kurt T; Speicher, David W

    2011-09-02

    Stable isotope dilution-multiple reaction monitoring-mass spectrometry (SID-MRM-MS) has emerged as a promising platform for verification of serological candidate biomarkers. However, cost and time needed to synthesize and evaluate stable isotope peptides, optimize spike-in assays, and generate standard curves quickly becomes unattractive when testing many candidate biomarkers. In this study, we demonstrate that label-free multiplexed MRM-MS coupled with major protein depletion and 1D gel separation is a time-efficient, cost-effective initial biomarker verification strategy requiring less than 100 μL of serum. Furthermore, SDS gel fractionation can resolve different molecular weight forms of targeted proteins with potential diagnostic value. Because fractionation is at the protein level, consistency of peptide quantitation profiles across fractions permits rapid detection of quantitation problems for specific peptides from a given protein. Despite the lack of internal standards, the entire workflow can be highly reproducible, and long-term reproducibility of relative protein abundance can be obtained using different mass spectrometers and LC methods with external reference standards. Quantitation down to ~200 pg/mL could be achieved using this workflow. Hence, the label-free GeLC-MRM workflow enables rapid, sensitive, and economical initial screening of large numbers of candidate biomarkers prior to setting up SID-MRM assays or immunoassays for the most promising candidate biomarkers.

  13. Measurement of Intracellular Ribavirin Mono-, Di- and Triphosphate Using Solid Phase Extraction and LC-MS/MS Quantification

    PubMed Central

    Jimmerson, Leah C.; Ray, Michelle L.; Bushman, Lane R.; Anderson, Peter L.; Klein, Brandon; Rower, Joseph E.; Zheng, Jia-Hua; Kiser, Jennifer J.

    2014-01-01

    Ribavirin (RBV) is a nucleoside analog used to treat a variety of DNA and RNA viruses. RBV undergoes intracellular phosphorylation to a mono- (MP), di- (DP), and triphosphate (TP). The phosphorylated forms have been associated with the mechanisms of antiviral effect observed in vitro, but the intracellular pharmacology of the drug has not been well characterized in vivo. A highly sensitive LC-MS/MS method was developed and validated for the determination of intracellular RBV MP, DP, and TP in multiple cell matrix types. For this method, the individual MP, DP, and TP fractions were isolated from lysed intracellular matrix using strong anion exchange solid phase extraction, dephosphorylated to parent RBV, desalted and concentrated and quantified using LC-MS/MS. The method utilized a stable labeled internal standard (RBV-13C5) which facilitated accuracy (% deviation within ±15%) and precision (coefficient of variation of ≤15%). The quantifiable linear range for the assay was 0.50 to 200 pmol/sample. The method was applied to the measurement of RBV MP, DP, and TP in human peripheral blood mononuclear cells (PBMC), red blood cells (RBC), and dried blood spot (DBS) samples obtained from patients taking RBV for the treatment of chronic Hepatitis C virus infection. PMID:25555148

  14. Identifying novel radiotracers for PET imaging of the brain: application of LC-MS/MS to tracer identification.

    PubMed

    Barth, Vanessa; Need, Anne

    2014-12-17

    Nuclear medicine imaging biomarker applications are limited by the radiotracers available. Radiotracers enable the measurement of target engagement, or occupancy in relation to plasma exposure. These tracers can also be used as pharmacodynamic biomarkers to demonstrate functional consequences of binding a target. More recently, radiotracers have also been used for patient tailoring in Alzheimer's disease seen with amyloid imaging. Radiotracers for the central nervous system (CNS) are challenging to identify, as they require a unique intersection of multiple properties. Recent advances in tangential technologies, along with the use of iterative learning for the purposes of deriving in silico models, have opened up additional opportunities to identify radiotracers. Mass spectral technologies and in silico modeling have made it possible to measure and predict in vivo characteristics of molecules to indicate potential tracer performance. By analyzing these data alongside other measures, it is possible to delineate guidelines to increase the likelihood of selecting compounds that can perform as radiotracers or serve as the best starting point to develop a radiotracer following additional structural modification. The application of mass spectrometry based technologies is an efficient way to evaluate compounds as tracers in vivo, but more importantly enables the testing of potential tracers that have either no label site or complex labeling chemistry which may deter assessment by traditional means; therefore, use of this technology allows for more rapid iterative learning. The ability to differentially distribute toward target rich tissues versus tissue with no/less target present is a unique defining feature of a tracer. By testing nonlabeled compounds in vivo and analyzing tissue levels by LC-MS/MS, rapid assessment of a compound's ability to differentially distribute in a manner consistent with target expression biology guides the focus of chemistry resources for both

  15. Verification of propofol sulfate as a further human propofol metabolite using LC-ESI-QQQ-MS and LC-ESI-QTOF-MS analysis.

    PubMed

    Maas, Alexandra; Maier, Christoph; Michel-Lauter, Beate; Broecker, Sebastian; Madea, Burkhard; Hess, Cornelius

    2017-03-01

    Propofol (2,6-diisopropylphenol) is a water-insoluble, intravenous anesthetic that is widely used for the induction and maintenance of anesthesia as well as for endoscopic and pediatric sedation. After admission, propofol undergoes extensive hepatic and extrahepatic metabolism, including direct conjugation to propofol glucuronide and hydroxylation to 2,6-diisopropyl-1,4-quinol. The latter substance subsequently undergoes phase II metabolism, resulting in the formation of further metabolites (1quinolglucuronide, 4quinolglucuronide and 4quinol-sulfate). Further minor phase I propofol metabolites (2-(ω-propanol)-6-isopropylphenol and 2-(ω-propanol)-6-isopropyl-1,4-quinol)) are also described. Due to its chemical structure with the phenolic hydroxyl group, propofol is also an appropriate substrate for sulfation by sulfotransferases. The existence of propofol sulfate was investigated by liquid chromatography electrospray ionization triple quadrupole mass spectrometry (LCESIQQQ-MS) and liquid chromatography electrospray ionization quadrupole time-of-flight mass spectrometry (LCESI-QTOF-MS). A propofol sulfate reference standard was used for identification and method development, yielding a precursor at m/z 257 (deprotonated propofol sulfate) and product ions at m/z 177 (deprotonated propofol) and m/z 80 ([SO3]-). Propofol sulfate - a further phase II metabolite of propofol - was verified in urine samples by LC-ESI-QQQ-MS and LC-ESI-QTOF-MS. Analyses of urine samples from five volunteers collected before and after propofol-induced sedation verified the presence of propofol sulfate in urine following propofol administration, whereas ascertained concentrations of this metabolite were significantly lower compared with detected propofol glucuronide concentrations. The existence of propofol sulfate as a further phase II propofol metabolite in humans could be verified by two different detection techniques (LCESIQQQ-MS and LC-ESI-QTOFMS) on the basis of a propofol sulfate

  16. Development of Chiral LC-MS Methods for small Molecules and Their Applications in the Analysis of Enantiomeric Composition and Pharmacokinetic Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Desai, Meera Jay

    The purpose of this research was to develop sensitive LC-MS methods for enantiomeric separation and detection, and then apply these methods for determination of enantiomeric composition and for the study of pharmacokinetic and pharmacodynamic properties of a chiral nutraceutical. Our first study, evaluated the use of reverse phase and polar organic mode for chiral LC-API/MS method development. Reverse phase methods containing high water were found to decrease ionization efficiency in electrospray, while polar organic methods offered good compatibility and low limits of detection with ESI. The use of lower flow rates dramatically increased the sensitivity by an order of magnitude.more » Additionally, for rapid chiral screening, the coupled Chirobiotic column afforded great applicability for LC-MS method development. Our second study, continued with chiral LC-MS method development in this case for the normal phase mode. Ethoxynonafluorobutane, a fluorocarbon with low flammability and no flashpoint, was used as a substitute solvent for hexane/heptane mobile phases for LC-APCI/MS. Comparable chromatographic resolutions and selectivities were found using ENFB substituted mobile phase systems, although, peak efficiencies were significantly diminished. Limits of detection were either comparable or better for ENFB-MS over heptane-PDA detection. The miscibility of ENFB with a variety of commonly used organic modifiers provided for flexibility in method development. For APCI, lower flow rates did not increase sensitivity as significantly as was previously found for ESI-MS detection. The chiral analysis of native amino acids was evaluated using both APCI and ESI sources. For free amino acids and small peptides, APCI was found to have better sensitivities over ESI at high flow rates. For larger peptides, however, sensitivity was greatly improved with the use of electrospray. Additionally, sensitivity was enhanced with the use of non-volatile additives, This optimized method

  17. Quantitation of melatonin and n-acetylserotonin in human plasma by nanoflow LC-MS/MS and electrospray LC-MS/MS.

    PubMed

    Carter, Melissa D; Calcutt, M Wade; Malow, Beth A; Rose, Kristie L; Hachey, David L

    2012-03-01

    Melatonin (MEL) and its chemical precursor N-acetylserotonin (NAS) are believed to be potential biomarkers for sleep-related disorders. Measurement of these compounds, however, has proven to be difficult due to their low circulating levels, especially that of NAS. Few methods offer the sensitivity, specificity and dynamic range needed to monitor MEL and its precursors and metabolites in small blood samples, such as those obtained from pediatric patients. In support of our ongoing study to determine the safety, tolerability and PK dosing strategies for MEL in treating insomnia in children with autism spectrum disorder, two highly sensitive LC-MS/MS assays were developed for the quantitation of MEL and precursor NAS at pg/mL levels in small volumes of human plasma. A validated electrospray ionization (ESI) method was used to quantitate high levels of MEL in PK studies, and a validated nanospray (nESI) method was developed for quantitation of MEL and NAS at endogenous levels. In both assays, plasma samples were processed by centrifugal membrane dialysis after addition of stable isotopic internal standards, and the components were separated by either conventional LC using a Waters SymmetryShield RP18 column (2.1 × 100  mm, 3.5 µm) or on a polyimide-coated, fused-silica capillary self-packed with 17 cm AquaC18 (3 µm, 125 Å). Quantitation was done using the SRM transitions m/z 233 → 174 and m/z 219 → 160 for MEL and NAS, respectively. The analytical response ratio versus concentration curves were linear for MEL (nanoflow LC: 11.7-1165  pg/mL, LC: 1165-116,500  pg/mL) and for NAS (nanoflow LC: 11.0-1095  pg/mL). Copyright © 2012 John Wiley & Sons, Ltd.

  18. Quantitation of Melatonin and N-acetylserotonin in Human Plasma by Nanoflow LC-MS/MS and Electrospray LC-MS/MS

    PubMed Central

    Carter, Melissa D.; Calcutt, M. Wade; Malow, Beth A.; Rose, Kristie L.; Hachey, David L.

    2012-01-01

    Melatonin (MEL) and its chemical precursor N-acetylserotonin (NAS) are believed to be potential biomarkers for sleep-related disorders. Measurement of these compounds, however, has proven to be difficult due to their low circulating levels, especially that of NAS. Few methods offer the sensitivity, specificity and dynamic range needed to monitor MEL and its precursors and metabolites in small blood samples, such as those obtained from pediatric patients. In support of our ongoing study to determine the safety, tolerability, and PK dosing strategies for MEL in treating insomnia in children with autism spectrum disorder, two highly sensitive LC-MS/MS assays were developed for the quantitation of MEL and precursor NAS at pg/mL levels in small volumes of human plasma. A validated electrospray ionization (ESI) method was used to quantitate high levels of MEL in PK studies and a validated nanospray (nESI) method was developed for quantitation of MEL and NAS at endogenous levels. In both assays plasma samples were processed by centrifugal membrane dialysis after addition of stable isotopic internal standards, and the components were separated by either conventional LC using a Waters SymmetryShield RP18 column (2.1×100 mm, 3.5 μm) or on a polyimide-coated, fused-silica capillary self-packed with 17 cm AquaC18 (3 μm, 125 Å). Quantitation was done using the SRM transitions m/z 233→174 and m/z 219→160 for MEL and NAS, respectively. The analytical response ratio vs. concentration curves were linear for MEL (nanoflow LC: 11.7–1165 pg/mL, LC: 1165–116500 pg/mL) and for NAS (nanoflow LC: 11.0–1095 pg/mL). PMID:22431453

  19. Fast targeted analysis of 132 acidic and neutral drugs and poisons in whole blood using LC-MS/MS.

    PubMed

    Di Rago, Matthew; Saar, Eva; Rodda, Luke N; Turfus, Sophie; Kotsos, Alex; Gerostamoulos, Dimitri; Drummer, Olaf H

    2014-10-01

    The aim of this study was to develop an LC-MS/MS based screening technique that covers a broad range of acidic and neutral drugs and poisons by combining a small sample volume and efficient extraction technique with simple automated data processing. After protein precipitation of 100μL of whole blood, 132 common acidic and neutral drugs and poisons including non-steroidal anti-inflammatory drugs, barbiturates, anticonvulsants, antidiabetics, muscle relaxants, diuretics and superwarfarin rodenticides (47 quantitated, 85 reported as detected) were separated using a Shimadzu Prominence HPLC system with a C18 separation column (Kinetex XB-C18, 4.6mm×150mm, 5μm), using gradient elution with a mobile phase of 25mM ammonium acetate buffer (pH 7.5)/acetonitrile. The drugs were detected using an ABSciex(®) API 2000 LC-MS/MS system (ESI+ and -, MRM mode, two transitions per analyte). The method was fully validated in accordance with international guidelines. Quantification data obtained using one-point calibration compared favorably to that using multiple calibrants. The presented LC-MS/MS assay has proven to be applicable for determination of the analytes in blood. The fast and reliable extraction method combined with automated processing gives the opportunity for high throughput and fast turnaround times for forensic and clinical toxicology. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. Applying quantitative metabolomics based on chemical isotope labeling LC-MS for detecting potential milk adulterant in human milk.

    PubMed

    Mung, Dorothea; Li, Liang

    2018-02-25

    There is an increasing demand for donor human milk to feed infants for various reasons including that a mother may be unable to provide sufficient amounts of milk for their child or the milk is considered unsafe for the baby. Selling and buying human milk via the Internet has gained popularity. However, there is a risk of human milk sold containing other adulterants such as animal or plant milk. Analytical tools for rapid detection of adulterants in human milk are needed. We report a quantitative metabolomics method for detecting potential milk adulterants (soy, almond, cow, goat and infant formula milk) in human milk. It is based on the use of a high-performance chemical isotope labeling (CIL) LC-MS platform to profile the metabolome of an unknown milk sample, followed by multivariate or univariate comparison of the resultant metabolomic profile with that of human milk to determine the differences. Using dansylation LC-MS to profile the amine/phenol submetabolome, we could detect an average of 4129 ± 297 (n = 9) soy metabolites, 3080 ± 470 (n = 9) almond metabolites, 4256 ± 136 (n = 18) cow metabolites, 4318 ± 198 (n = 9) goat metabolites, 4444 ± 563 (n = 9) infant formula metabolites, and 4020 ± 375 (n = 30) human metabolites. This high level of coverage allowed us to readily differentiate the six different types of samples. From the analysis of binary mixtures of human milk containing 5, 10, 25, 50 and 75% other type of milk, we demonstrated that this method could be used to detect the presence of as low as 5% adulterant in human milk. We envisage that this method could be applied to detect contaminant or adulterant in other types of food or drinks. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Contaminant screening of wastewater with HPLC-IM-qTOF-MS and LC+LC-IM-qTOF-MS using a CCS database.

    PubMed

    Stephan, Susanne; Hippler, Joerg; Köhler, Timo; Deeb, Ahmad A; Schmidt, Torsten C; Schmitz, Oliver J

    2016-09-01

    Non-target analysis has become an important tool in the field of water analysis since a broad variety of pollutants from different sources are released to the water cycle. For identification of compounds in such complex samples, liquid chromatography coupled to high resolution mass spectrometry are often used. The introduction of ion mobility spectrometry provides an additional separation dimension and allows determining collision cross sections (CCS) of the analytes as a further physicochemical constant supporting the identification. A CCS database with more than 500 standard substances including drug-like compounds and pesticides was used for CCS data base search in this work. A non-target analysis of a wastewater sample was initially performed with high performance liquid chromatography (HPLC) coupled to an ion mobility-quadrupole-time of flight mass spectrometer (IM-qTOF-MS). A database search including exact mass (±5 ppm) and CCS (±1 %) delivered 22 different compounds. Furthermore, the same sample was analyzed with a two-dimensional LC method, called LC+LC, developed in our group for the coupling to IM-qTOF-MS. This four dimensional separation platform revealed 53 different compounds, identified over exact mass and CCS, in the examined wastewater sample. It is demonstrated that the CCS database can also help to distinguish between isobaric structures exemplified for cyclophosphamide and ifosfamide. Graphical Abstract Scheme of sample analysis and database screening.

  2. Measurement of trace levels of antibiotics in river water using on-line enrichment and triple-quadrupole LC-MS/MS.

    PubMed

    Dinh, Quoc Tuc; Alliot, Fabrice; Moreau-Guigon, Elodie; Eurin, Joëlle; Chevreuil, Marc; Labadie, Pierre

    2011-09-15

    This study presents the development of an automated on-line solid phase extraction (SPE)-liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of 23 antibiotics in environmental water samples. After optimisation of LC-MS/MS conditions, SPE parameters such as sorbent type, sample pH or sample volume were optimised. Antibiotic recoveries ranged from 64% to 98% and compared favourably with those achieved using off-line SPE. Limits of detection were in the range 0.5-13.7 ng L(-1). This on-line SPE-LC-MS/MS procedure was applied to the analysis of water samples taken in three rivers within the Seine River basin, near Paris (France). The obtained results revealed the occurrence of 12 antibiotics, including tylosin, erythromycin, tetracycline, amoxicillin, trimethoprim, sulfamethoxazole, oxolinic acid, flumequine, norfloxacin, ciprofloxacin, ofloxacin, and vancomycin (2-1435 ng L(-1)). Copyright © 2011 Elsevier B.V. All rights reserved.

  3. LC-MS/MS profiling-based secondary metabolite screening of Myxococcus xanthus.

    PubMed

    Kim, Jiyoung; Choi, Jung Nam; Kim, Pil; Sok, Dai-Eun; Nam, Soo-Wan; Lee, Choong Hwan

    2009-01-01

    Myxobacteria, Gram-negative soil bacteria, are a well-known producer of bioactive secondary metabolites. Therefore, this study presents a methodological approach for the high-throughput screening of secondary metabolites from 4 wild-type Myxococcus xanthus strains. First, electrospray ionization mass spectrometry (ESI-MS) was performed using extracellular crude extracts. As a result, 22 metabolite peaks were detected, and the metabolite profiling was then conducted using the m/z value, retention time, and MS/MS fragmentation pattern analyses. Among the peaks, one unknown compound peak was identified as analogous to the myxalamid A, B, and C series. An analysis of the tandem mass spectrometric fragmentation patterns and HR-MS identified myxalamid K as a new compound derived from M. xanthus. In conclusion, LC-MS/MS-based chemical screening of diverse secondary metabolites would appear to be an effective approach for discovering unknown microbial secondary metabolites.

  4. Investigation of epigallocatechin-3-O-caffeoate and epigallocatechin-3-O-p-coumaroate in tea leaves by LC/MS-MS analysis.

    PubMed

    Umehara, Masahiro; Yanae, Koji; Maruki-Uchida, Hiroko; Sai, Masahiko

    2017-12-01

    (-)-Epigallocatechin-3-O-gallate (EGCG), the major catechin present in green tea, exhibits potent antioxidant activity. We thereby investigated the presence of unknown components bearing the (-)-epigallocatechin (EGC) moiety in fresh tea leaf samples. Initially, liquid chromatography tandem mass spectrometry (LC-MS/MS) was employed to examine fresh tea leaves of the Yabukita, the most popular tea cultivar in Japan, which suggested the presence of the EGC phenylpropanoid derivatives, (-)-epigallocatechin-3-O-p-coumaroate (EGCpCA) and (-)-epigallocatechin-3-O-caffeoate (EGCCA). The structures of the detected EGCpCA and EGCCA were then confirmed by LC-MS/MS using synthesized EGCpCA and EGCCA as standards. In addition, EGCpCA and EGCCA were evaluated for their antioxidant activity in the ORAC (oxygen radical antioxidant capacity) and DPPH (2,2-diphenyl-1-picrylhydrazyl) radical scavenging assays, where EGCCA (8.60μmolTE/μmol, TE=Trolox equivalents) exhibited a stronger antioxidant activity than EGCG (5.52μmolTE/μmol) in the ORAC assay. Finally, EGCpCA and EGCCA were quantitated in several tea leaf samples using LC-MS/MS, and it was found that these compounds were present in lower quantities (EGCpCA, 16.8-345.8μg/g, EGCCA, 4.3-75.1μg/g in the dry tea leaves) than the major catechins. In this study, we found the potent antioxidant EGCCA using LC-MS/MS and revealed its wide existence in various tea leaves. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Quantitative evaluation of protein conformation in pharmaceuticals using cross-linking reactions coupled with LC-MS/MS analysis.

    PubMed

    Yamaguchi, Hideto; Hirakura, Yutaka; Shirai, Hiroki; Mimura, Hisashi; Toyo'oka, Toshimasa

    2011-06-01

    The need for a simple and high-throughput method for identifying the tertiary structure of protein pharmaceuticals has increased. In this study, a simple method for mapping the protein fold is proposed for use as a complementary quality test. This method is based on cross-linking a protein using a [bis(sulfosuccinimidyl)suberate (BS(3))], followed by peptide mapping by LC-MS. Consensus interferon (CIFN) was used as the model protein. The tryptic map obtained via liquid chromatography tandem mass spectroscopy (LC-MS/MS) and the mass mapping obtained via matrix-assisted laser desorption/ionization time-of-flight mass spectroscopy were used to identify cross-linked peptides. While LC-MS/MS analyses found that BS(3) formed cross-links in the loop region of the protein, which was regarded as the biologically active site, sodium dodecyl-sulfate polyacrylamide gel electrophoresis demonstrated that cross-linking occurred within a protein molecule, but not between protein molecules. The occurrence of cross-links at the active site depends greatly on the conformation of the protein, which is determined by the denaturing conditions. Quantitative evaluation of the tertiary structure of CIFN was thus possible by monitoring the amounts of cross-linked peptides generated. Assuming that background information is available at the development stage, this method may be applicable to process development as a complementary test for quality control. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. MicroSPE-nanoLC-ESI-MS/MS Using 10-μm-i.d. Silica-Based Monolithic Columns for Proteomics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luo, Quanzhou; Page, Jason S.; Tang, Keqi

    2007-01-01

    Silica-based monolithic narrow bore capillary columns (25 cm x 10 µm i.d.) with an integrated nanoESI emitter has been developed to provide high quality and robust microSPE-nanoLC-ESI-MS analyses. The integrated nanoESI emitter adds no dead volume to the LC separation, allowing stable electrospray performance to be obtained at flow rates of ~10 nL/min. In an initial application we identified 5510 unique peptides covering 1443 distinct Shewanella oneidensis proteins from a 300 ng tryptic digest sample in a single 4-h LC-MS/MS analysis using a linear ion trap MS (LTQ). We found the use of an integrated monolithic ESI emitter provided enhancedmore » resistance to clogging and good run-to-run reproducibility.« less

  7. LC-ESI-MS/MS identification of polar lipids of two thermophilic Anoxybacillus bacteria containing a unique lipid pattern.

    PubMed

    Rezanka, Tomáš; Kambourova, Margarita; Derekova, Anna; Kolouchová, Irena; Sigler, Karel

    2012-07-01

    Phospholipids and glycolipids from two recently described species belonging to the thermophilic genus Anoxybacillus were analyzed by liquid chromatography-electrospray tandem mass spectrometry (LC/ESI-MS/MS). Analysis of total lipids from the facultatively anaerobic A. bogrovensis on a HILIC (Hydrophilic Interaction LIquid Chromatography) column succeeded in separating diacyl- and plasmalogen phospholipids. The LC/ESI-MS/MS analysis of the strict aerobe A. rupiensis revealed the presence of different unique polar lipids, predominantly alanyl-, lysyl-, and glucosyl-phosphatidylglycerols and cardiolipins. Each of the classes of polar lipids was then analyzed by means of the ESI-MS/MS and more than 140 molecular species of six lipid classes from A. bogrovensis and nearly 200 molecular species of nine classes of polar lipids from A. rupiensis were identified. Five classes of unidentified polar lipids were detected in both strains. Plasmalogens were thus determined for the first time in a facultatively anaerobic bacterium, i.e. A. bogrovensis.

  8. Identification of BVT.2938 metabolites by LC/MS and LC/MS/MS after in vitro incubations with liver microsomes and hepatocytes.

    PubMed

    Edlund, Per Olof; Baranczewski, Pawel

    2004-03-10

    The metabolism of the 5HT2c agonist BVT.2938, 1-(3-[2-[(2-ethoxy-3-pyridinyl)oxy]ethoxy]-2-pyrazinyl)-2(R)-methylpiperazine, was studied in vitro by incubation with rat, monkey and human liver microsomes as well as cryopreserved hepatocytes, followed by liquid chromatography/mass spectrometry (LC/MS) and LC/MS/MS analysis on a quadrupole-time of flight mass spectrometer for structural elucidation. Deuterium exchange on column was used to differentiate between hydroxylation and N-oxidation. Liver microsomes were incubated in two different buffer systems with optimum conditions for cytochrome P450 activity or UDP-glucuronosyltransferase activity. The major phase I metabolites of BVT.2938 originated from O-deethylation of the pyridine ring, O-dealkylation of the ethylene bridge, pyrazine ring hydroxylation, hydroxylation of pyridine ring and piperazine ring N-hydroxylation. When a hydrogen carbonate buffer system was supplemented with UDPGA, the piperazine carbamoyl-glucuronide from the parent compound was identified together with several glucuronides of the phase I metabolites. The metabolite pattern in hepatocytes was similar to microsomes except that the sulphate at the N-position of the piperazine ring of BVT.2938 was identified, while the carbamoyl-glucuronide was missing. Excellent correlation was obtained between radioactivity detection and the chemiluminescent nitrogen detector when the nitrogen content of the analytes was taken into account.

  9. Non-enzymolytic adenosine barcode-mediated dual signal amplification strategy for ultrasensitive protein detection using LC-MS/MS.

    PubMed

    Yang, Wen; Li, Tengfei; Shu, Chang; Ji, Shunli; Wang, Lei; Wang, Yan; Li, Duo; Mtalimanja, Michael; Sun, Luning; Ding, Li

    2018-05-10

    A method is described for the determination of proteins with LC-MS/MS enabled by a small molecule (adenosine) barcode and based on a double-recognition sandwich structure. The coagulation protein thrombin was chosen as the model analyte. Magnetic nanoparticles were functionalized with aptamer29 (MNP/apt29) and used to capture thrombin from the samples. MNP/apt29 forms a sandwich with functionalized gold nanoparticles modified with (a) aptamer15 acting as thrombin-recognizing element and (b) a large number of adenosine as mass barcodes. The sandwich formed (MNP/apt29-thrombin-apt15/AuNP/adenosine) can ben magnetically separated from the sample. Mass barcodes are subsequently released from the sandwiched structure for further analysis by adding 11-mercaptoundecanoic acid. Adenosine is then detected by LC-MS/MS as it reflects the level of thrombin with impressively amplified signal. Numerous adenosines introduced into the sandwich proportional to the target concentration further amplify the signal. Under optimized conditions, the response is linearly proportional to the thrombin concentration in the range of 0.02 nM to 10 nM, with a detection limit of 9 fM. The application of this method to the determination of thrombin in spiked plasma samples gave recoveries that ranged from 92.3% to 104.7%. Graphical abstract Schematic representation of a method for the determination of thrombin with LC-MS/MS. The method is based on a double-recognition sandwiched structure. With LC-MS/MS, mass barcodes (adenosine) are detected to quantify thrombin, which amplifies the detection signal impressively.

  10. LC-MS guided isolation of ent-kaurane diterpenoids from Nouelia insignis.

    PubMed

    Sun, Chang-Li; Geng, Chang-An; Chen, Xing-Long; Yang, Tong-Hua; Yin, Xiu-Juan; Huang, Xiao-Yan; Peng, Hua; Chen, Ji-Jun

    2016-06-01

    The preliminary LC-MS investigation on the stems of Nouelia insignis manifested the existence of diterpenoids. As a result, 15 ent-kaurane diterpenoids, including 7 new glycosides (nouelosides A-G, 1-7), were isolated under the direction of LC-MS analysis. The new compounds were determined by extensive spectroscopic analysis including HRESIMS, 1D and 2D NMR data and chemical methods. Compounds 6 and 15 with the exo-methylene cyclopentanone functional group exhibited obvious nitric oxide production inhibitory activity with IC50 values of 3.84±0.20 and 3.19±0.25μM. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. High-throughput, 384-well, LC-MS/MS CYP inhibition assay using automation, cassette-analysis technique, and streamlined data analysis.

    PubMed

    Halladay, Jason S; Delarosa, Erlie Marie; Tran, Daniel; Wang, Leslie; Wong, Susan; Khojasteh, S Cyrus

    2011-08-01

    Here we describe a high capacity and high-throughput, automated, 384-well CYP inhibition assay using well-known HLM-based MS probes. We provide consistently robust IC(50) values at the lead optimization stage of the drug discovery process. Our method uses the Agilent Technologies/Velocity11 BioCel 1200 system, timesaving techniques for sample analysis, and streamlined data processing steps. For each experiment, we generate IC(50) values for up to 344 compounds and positive controls for five major CYP isoforms (probe substrate): CYP1A2 (phenacetin), CYP2C9 ((S)-warfarin), CYP2C19 ((S)-mephenytoin), CYP2D6 (dextromethorphan), and CYP3A4/5 (testosterone and midazolam). Each compound is incubated separately at four concentrations with each CYP probe substrate under the optimized incubation condition. Each incubation is quenched with acetonitrile containing the deuterated internal standard of the respective metabolite for each probe substrate. To minimize the number of samples to be analyzed by LC-MS/MS and reduce the amount of valuable MS runtime, we utilize timesaving techniques of cassette analysis (pooling the incubation samples at the end of each CYP probe incubation into one) and column switching (reducing the amount of MS runtime). Here we also report on the comparison of IC(50) results for five major CYP isoforms using our method compared to values reported in the literature.

  12. Positive and negative electrospray LC-MS-MS methods for quantitation of the antiparasitic endectocide drugs, abamectin, doramectin, emamectin, eprinomectin, ivermectin, moxidectin and selamectin in milk.

    PubMed

    Durden, David A

    2007-05-01

    Avermectin endectocides are used for the treatment of cattle against a variety of nematode and arthropod parasites, and consequently may appear in milk after normal or off-label use. The compounds abamectin, doramectin, and ivermectin, contain only C, H and O and may be expected to be detected by LC-MS in negative ion mode. The others contain nitrogen in addition and would be expected to be preferentially ionized in positive mode. The use of positive ion and negative ion methods with electrospray LC-MS-MS were compared. Using negative ion the compounds abamectin, doramectin, ivermectin, emamectin, eprinomectin, and moxidectin gave a curvilinear response and were quantified in raw milk by LC-MS-MS with a triethylamine-acetonitrile buffer over the concentration range 1-60 ppb (microg/kg) using selamectin as the internal standard. The limits of detection (LOD) were between 0.19 ppb (doramectin) and 0.38 ppb (emamectin). The compounds gave maximum sensitivity with positive ionisation from a formic acid-ammonium formate-acetonitrile buffer and were detected in milk (LC-MS-MS) also with a curvilinear response over the range 0.5-60 ppb. Although the positive ion signals were larger, with somewhat lower limits of detection (LOD between 0.06 ppb (doramectin) and 0.32 ppb (moxidectin) the negative ion procedure gave a more linear response and more consistent results. Comparison of spiked samples in the range 2-50 ppb showed a high degree of correlation between the two methods.

  13. A Liquid Chromatographic-Mass Spectrometric (LC-MS) Method for the Analysis of the Bis-pyridinium Oxime ICD-585 in Plasma: Application in a Guinea Pig Model

    DTIC Science & Technology

    2010-01-01

    Chrom LCMS...Literature 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE A liquid chromatographic–mass spectrometric ( LCMS) method for the analysis of the 5a...Journal of Chromatography B journa l homepage: www.e lsev ier .com/ locate /chromb A liquid chromatographic–mass spectrometric ( LCMS) method for

  14. Chemical derivatization for enhancing sensitivity during LC/ESI-MS/MS quantification of steroids in biological samples: a review.

    PubMed

    Higashi, Tatsuya; Ogawa, Shoujiro

    2016-09-01

    Sensitive and specific methods for the detection, characterization and quantification of endogenous steroids in body fluids or tissues are necessary for the diagnosis, pathological analysis and treatment of many diseases. Recently, liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) has been widely used for these purposes due to its specificity and versatility. However, the ESI efficiency and fragmentation behavior of some steroids are poor, which lead to a low sensitivity. Chemical derivatization is one of the most effective methods to improve the detection characteristics of steroids in ESI-MS/MS. Based on this background, this article reviews the recent advances in chemical derivatization for the trace quantification of steroids in biological samples by LC/ESI-MS/MS. The derivatization in ESI-MS/MS is based on tagging a proton-affinitive or permanently charged moiety on the target steroid. Introduction/formation of a fragmentable moiety suitable for the selected reaction monitoring by the derivatization also enhances the sensitivity. The stable isotope-coded derivatization procedures for the steroid analysis are also described. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Metabolism of the new psychoactive substances N,N-diallyltryptamine (DALT) and 5-methoxy-DALT and their detectability in urine by GC-MS, LC-MSn, and LC-HR-MS-MS.

    PubMed

    Michely, Julian A; Helfer, Andreas G; Brandt, Simon D; Meyer, Markus R; Maurer, Hans H

    2015-10-01

    N,N-Diallyltryptamine (DALT) and 5-methoxy-DALT (5-MeO-DALT) are synthetic tryptamine derivatives commonly referred to as so-called new psychoactive substances (NPS). They have psychoactive effects that may be similar to those of other tryptamine derivatives. The objectives of this work were to study the metabolic fate and detectability, in urine, of DALT and 5-MeO-DALT. For metabolism studies, rat urine obtained after high-dose administration was prepared by precipitation and analyzed by liquid chromatography-high-resolution mass spectrometry (LC-HR-MS-MS). On the basis of the metabolites identified, several aromatic and aliphatic hydroxylations, N-dealkylation, N-oxidation, and combinations thereof are proposed as the main metabolic pathways for both compounds. O-Demethylation of 5-MeO-DALT was also observed, in addition to extensive glucuronidation or sulfation of both compounds after phase I transformation. The cytochrome P450 (CYP) isoenzymes predominantly involved in DALT metabolism were CYP2C19, CYP2D6, and CYP3A4; those mainly involved in 5-MeO-DALT metabolism were CYP1A2, CYP2C19, CYP2D6, and CYP3A4. For detectability studies, rat urine was screened by GC-MS, LC-MS(n), and LC-HR-MS-MS after administration of low doses. LC-MS(n) and LC-HR-MS-MS were deemed suitable for monitoring consumption of both compounds. The most abundant targets were a ring hydroxy metabolite of DALT, the N,O-bis-dealkyl metabolite of 5-MeO-DALT, and their glucuronides. GC-MS enabled screening of DALT by use of its main metabolites only.

  16. LC/MS Method for the Determination of Stable Isotope Labeled Promethazine in Human Plasma

    NASA Technical Reports Server (NTRS)

    Zuwei, Wang; Boyd, Jason; Berens, Kurt L.; Putcha, Lakshmi

    2004-01-01

    Promethazine (PMZ) is taken by astronauts orally (PO), intramuscularly (IM) or rectally (PR) for space motion sickness. LC/MS method was developed with off-line solid phase extraction to measure plasma concentrations of PMZ given as stable isotope-labeled (SIL) formulations by the three different routes of administration simultaneously. Samples (0.5ml) were loaded on to Waters Oasis HLB co-polymer cartridges and eluted with 1.0 mL methanol. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 6 min. Acetonitrile/ ammonium acetate (30 mM) in water (3:2, v/v), pH 5.6 plus or minus 0.1, was used as the mobile phase for separation. Concentrations of PMZ, PMZ-d4 and PMZ-d7 and chlorpromazine (internal standard) were determined using a Micromass ZMD single quadrupole mass spectrometer with Electrospray Ionization (ESI). ESI mass spectra were acquired in positive ion mode with selected ion monitoring of [M+ H]dot plus. The method is rapid, reproducible and the assay specific parameters are listed in a table. A novel, sensitive and specific method for the measurement of PMZ and SIL PMZ in human plasma is reported.

  17. Label-free quantitative proteomic analysis of human plasma-derived microvesicles to find protein signatures of abdominal aortic aneurysms.

    PubMed

    Martinez-Pinna, Roxana; Gonzalez de Peredo, Anne; Monsarrat, Bernard; Burlet-Schiltz, Odile; Martin-Ventura, Jose Luis

    2014-08-01

    To find potential biomarkers of abdominal aortic aneurysms (AAA), we performed a differential proteomic study based on human plasma-derived microvesicles. Exosomes and microparticles isolated from plasma of AAA patients and control subjects (n = 10 each group) were analyzed by a label-free quantitative MS-based strategy. Homemade and publicly available software packages have been used for MS data analysis. The application of two kinds of bioinformatic tools allowed us to find differential protein profiles from AAA patients. Some of these proteins found by the two analysis methods belong to main pathological mechanisms of AAA such as oxidative stress, immune-inflammation, and thrombosis. Data analysis from label-free MS-based experiments requires the use of sophisticated bioinformatic approaches to perform quantitative studies from complex protein mixtures. The application of two of these bioinformatic tools provided us a preliminary list of differential proteins found in plasma-derived microvesicles not previously associated to AAA, which could help us to understand the pathological mechanisms related to this disease. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. An LC-IMS-MS Platform Providing Increased Dynamic Range for High-Throughput Proteomic Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, Erin Shammel; Livesay, Eric A.; Orton, Daniel J.

    2010-02-05

    A high-throughput approach and platform using 15 minute reversed-phase capillary liquid chromatography (RPLC) separations in conjunction with ion mobility spectrometry-mass spectrometry (IMS-MS) measurements was evaluated for the rapid analysis of complex proteomics samples. To test the separation quality of the short LC gradient, a sample was prepared by spiking twenty reference peptides at varying concentrations from 1 ng/mL to 10 µg/mL into a tryptic digest of mouse blood plasma and analyzed with both a LC-Linear Ion Trap Fourier Transform (FT) MS and LC-IMS-TOF MS. The LC-FT MS detected thirteen out of the twenty spiked peptides that had concentrations ≥100 ng/mL.more » In contrast, the drift time selected mass spectra from the LC-IMS-TOF MS analyses yielded identifications for nineteen of the twenty peptides with all spiking level present. The greater dynamic range of the LC-IMS-TOF MS system could be attributed to two factors. First, the LC-IMS-TOF MS system enabled drift time separation of the low concentration spiked peptides from the high concentration mouse peptide matrix components, reducing signal interference and background, and allowing species to be resolved that would otherwise be obscured by other components. Second, the automatic gain control (AGC) in the linear ion trap of the hybrid FT MS instrument limits the number of ions that are accumulated to reduce space charge effects, but in turn limits the achievable dynamic range compared to the TOF detector.« less

  19. [Simultaneous determination of pesticide residues in agricultural products by LC-MS/MS].

    PubMed

    Watanabe, Minae; Ueno, Eiji; Inoue, Tomomi; Ohno, Haruka; Ikai, Yoshitomo; Morishita, Toshio; Oshima, Harumi; Hayashi, Rumiko

    2013-01-01

    A method for the simultaneous determination of multiple pesticide residues in agricultural products was developed by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). The sample was extracted with acetonitrile. Co-extractives were removed by GPC/graphitized carbon column SPE, and silica gel/PSA cartridge column SPE. Pesticides in the test solution were determined by LC-MS/MS using scheduled MRM. Recoveries of 124 pesticides from spinach, brown rice, soybean, orange and tomato were tested at the level of 0.1 µg/g, and those of 121 pesticides ranged from 70 to 120% (RSD≤15%). Pesticide residues in 239 agricultural products were investigated by this method, and residues of 49 pesticides were detected in 98 agricultural products.

  20. Misleading measures in Vitamin D analysis: a novel LC-MS/MS assay to account for epimers and isobars.

    PubMed

    Shah, Iltaf; James, Ricky; Barker, James; Petroczi, Andrea; Naughton, Declan P

    2011-05-14

    Recently, the accuracies of many commercially available immunoassays for Vitamin D have been questioned. Liquid chromatography tandem mass spectrometry (LC- MS/MS) has been shown to facilitate accurate separation and quantification of the major circulating metabolite 25-hydroxyvitamin-D3 (25OHD3) and 25-hydroxyvitamin-D2 (25OHD2) collectively termed as 25OHD. However, among other interferents, this method may be compromised by overlapping peaks and identical masses of epimers and isobars, resulting in inaccuracies in circulating 25OHD measurements. The aim of this study was to develop a novel LC-MS/MS method that can accurately identify and quantitate 25OHD3 and 25OHD2 through chromatographic separation of 25OHD from its epimers and isobars. A positive ion electrospray ionisation (ESI) LC-MS/MS method was used in the Multiple Reaction Monitoring (MRM) mode for quantification. It involved i) liquid-liquid extraction, ii) tandem columns (a high resolution ZORBAX C18 coupled to an ULTRON chiral, with guard column and inlet filter), iii) Stanozolol-D3 as internal standard, and iv) identification via ESI and monitoring of three fragmentation transitions. To demonstrate the practical usefulness of our method, blood samples were collected from 5 healthy male Caucasian volunteers; age range 22 to 37 years and 25OHD2, 25OHD3 along with co-eluting epimers and analogues were quantified. The new method allowed chromatographic separation and quantification of 25OHD2, 25OHD3, along with 25OHD3 epimer 3-epi-25OHD3 and isobars 1-α-hydroxyvitamin-D3 (1αOHD3), and 7-α-hydroxy-4-cholesten-3-one (7αC4). The new assay was capable of detecting 0.25 ng/mL of all analytes in serum. To our knowledge, this is the first specific, reliable, reproducible and robust LC-MS/MS method developed for the accurate detection of 25OHD (Vitamin D). The method is capable of detecting low levels of 25OHD3 and 25OHD2 together with chromatographic separation from the co-eluting epimers and isobars and

  1. Development and Validation of a Novel LC-MS/MS Opioid Confirmation Assay: Evaluation of β-glucuronidase Enzymes and Sample Cleanup Methods.

    PubMed

    Yang, He S; Wu, Alan H B; Lynch, Kara L

    2016-06-01

    With the rise in the use and misuse of prescription opioids, there is an increasing need for the confirmed identification of opioid analgesics in toxicology laboratories. The goals of this study were to (i) systematically evaluate the hydrolysis efficiency of four β-glucuronidase enzymes under optimized condition; (ii) evaluate compound recovery, matrix effects and precision of three protein precipitation plates and (iii) develop and validate a qualitative liquid-chromatography mass spectrometry (LC-MS/MS) assay to identify 13 opioids in urine. A recombinant β-glucuronidase exhibited the best overall hydrolysis efficiency for seven opioid glucuronide conjugates compared with β-glucuronidase from red abalone, Escherichia coli and Patella vulgata One of the protein precipitation plates tested exhibited overall better recovery of the opioids and lower ion suppression compared with the other two plates. An ESI positive mode LC-MS/MS assay for qualitative opioid analysis was developed and validated. Linearity, LOD, precision, matrix effect, recovery, carryover and interference of the method were evaluated. Sixty-two patient samples were analyzed by both a legacy GC-MS opioid method and the LC-MS/MS method, and 22 samples were analyzed by the LC-MS/MS and an LC-MS/MS reference method. The results of the comparisons showed good concordance. Overall, we described an efficient sample preparation procedure for a sensitive qualitative opioid confirmation assay in urine. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Importance of highly selective LC-MS/MS analysis for the accurate quantification of tamoxifen and its metabolites: focus on endoxifen and 4-hydroxytamoxifen.

    PubMed

    Jager, N G L; Rosing, H; Linn, S C; Schellens, J H M; Beijnen, J H

    2012-06-01

    The antiestrogenic effect of tamoxifen is mainly attributable to the active metabolites endoxifen and 4-hydroxytamoxifen. This effect is assumed to be concentration-dependent and therefore quantitative analysis of tamoxifen and metabolites for clinical studies and therapeutic drug monitoring is increasing. We investigated the large discrepancies in reported mean endoxifen and 4-hydroxytamoxifen concentrations. Two published LC-MS/MS methods are used to analyse a set of 75 serum samples from patients treated with tamoxifen. The method from Teunissen et al. (J Chrom B, 879:1677-1685, 2011) separates endoxifen and 4-hydroxytamoxifen from other tamoxifen metabolites with similar masses and fragmentation patterns. The second method, published by Gjerde et al. (J Chrom A, 1082:6-14, 2005) however lacks selectivity, resulting in a factor 2-3 overestimation of the endoxifen and 4-hydroxytamoxifen levels, respectively. We emphasize the use of highly selective LC-MS/MS methods for the quantification of tamoxifen and its metabolites in biological samples.

  3. Determination of chlormequat in pig serum and sow milk by LC-MS/MS.

    PubMed

    Poulsen, M E; Christensen, H B; Sørensen, M T; Leffers, H; Andersen, J H

    2007-11-01

    Chlormequat is a plant growth regulator widely used on cereals, and there is general concern that it may impair human fertility. A LC-MS/MS method for the analysis of chlormequat in milk and serum was developed and validated in connection with an investigation on the effect of chlormequat on pig reproduction. Validation of the method was based on recovery tests at three spiking levels, determined as double determinations and repeated at least four times. Samples were extracted with methanol-water-acetic acid, centrifuged, filtrated and determined by LC-MS/MS. The mean recoveries were in the range 80-110%, and the LOD was 0.2 ng/g for serum and 0.3 ng/g for milk. The values for repeatability and reproducibility were within 2/3 of the limits given by the Horwitz equation. Samples of pig serum (59) and sow milk (27) were analyzed using the method. Chlormequat was determined in four milk samples in the range of 0.4 ng/g to 1.2 ng/g and in all serum samples in the range of 0.2 ng/g-4.0 ng/g.

  4. A multi-center study benchmarks software tools for label-free proteome quantification

    PubMed Central

    Gillet, Ludovic C; Bernhardt, Oliver M.; MacLean, Brendan; Röst, Hannes L.; Tate, Stephen A.; Tsou, Chih-Chiang; Reiter, Lukas; Distler, Ute; Rosenberger, George; Perez-Riverol, Yasset; Nesvizhskii, Alexey I.; Aebersold, Ruedi; Tenzer, Stefan

    2016-01-01

    The consistent and accurate quantification of proteins by mass spectrometry (MS)-based proteomics depends on the performance of instruments, acquisition methods and data analysis software. In collaboration with the software developers, we evaluated OpenSWATH, SWATH2.0, Skyline, Spectronaut and DIA-Umpire, five of the most widely used software methods for processing data from SWATH-MS (sequential window acquisition of all theoretical fragment ion spectra), a method that uses data-independent acquisition (DIA) for label-free protein quantification. We analyzed high-complexity test datasets from hybrid proteome samples of defined quantitative composition acquired on two different MS instruments using different SWATH isolation windows setups. For consistent evaluation we developed LFQbench, an R-package to calculate metrics of precision and accuracy in label-free quantitative MS, and report the identification performance, robustness and specificity of each software tool. Our reference datasets enabled developers to improve their software tools. After optimization, all tools provided highly convergent identification and reliable quantification performance, underscoring their robustness for label-free quantitative proteomics. PMID:27701404

  5. Structural Feature Ions for Distinguishing N- and O-Linked Glycan Isomers by LC-ESI-IT MS/MS

    NASA Astrophysics Data System (ADS)

    Everest-Dass, Arun V.; Abrahams, Jodie L.; Kolarich, Daniel; Packer, Nicolle H.; Campbell, Matthew P.

    2013-06-01

    Glycomics is the comprehensive study of glycan expression in an organism, cell, or tissue that relies on effective analytical technologies to understand glycan structure-function relationships. Owing to the macro- and micro-heterogeneity of oligosaccharides, detailed structure characterization has required an orthogonal approach, such as a combination of specific exoglycosidase digestions, LC-MS/MS, and the development of bioinformatic resources to comprehensively profile a complex biological sample. Liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS/MS) has emerged as a key tool in the structural analysis of oligosaccharides because of its high sensitivity, resolution, and robustness. Here, we present a strategy that uses LC-ESI-MS/MS to characterize over 200 N- and O-glycans from human saliva glycoproteins, complemented by sequential exoglycosidase treatment, to further verify the annotated glycan structures. Fragment-specific substructure diagnostic ions were collated from an extensive screen of the literature available on the detailed structural characterization of oligosaccharides and, together with other specific glycan structure feature ions derived from cross-ring and glycosidic-linkage fragmentation, were used to characterize the glycans and differentiate isomers. The availability of such annotated mass spectrometric fragmentation spectral libraries of glycan structures, together with such substructure diagnostic ions, will be key inputs for the future development of the automated elucidation of oligosaccharide structures from MS/MS data.

  6. An analytical approach based on ESI-MS, LC-MS and PCA for the quali-quantitative analysis of cycloartane derivatives in Astragalus spp.

    PubMed

    Napolitano, Assunta; Akay, Seref; Mari, Angela; Bedir, Erdal; Pizza, Cosimo; Piacente, Sonia

    2013-11-01

    Astragalus species are widely used as health foods and dietary supplements, as well as drugs in traditional medicine. To rapidly evaluate metabolite similarities and differences among the EtOH extracts of the roots of eight commercial Astragalus spp., an approach based on direct analyses by ESI-MS followed by PCA of ESI-MS data, was carried out. Successively, quali-quantitative analyses of cycloartane derivatives in the eight Astragalus spp. by LC-ESI-MS(n) and PCA of LC-ESI-MS data were performed. This approach allowed to promptly highlighting metabolite similarities and differences among the various Astragalus spp. PCA results from LC-ESI-MS data of Astragalus samples were in reasonable agreement with both PCA results of ESI-MS data and quantitative results. This study affords an analytical method for the quali-quantitative determination of cycloartane derivatives in herbal preparations used as health and food supplements. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Determination of toxins involved in ciguatera fish poisoning in the Pacific by LC/MS.

    PubMed

    Yogi, Kentaro; Sakugawa, Satsuki; Oshiro, Naomasa; Ikehara, Tsuyoshi; Sugiyama, Kiminori; Yasumoto, Takeshi

    2014-01-01

    Ciguatera fish poisoning is the most extensive and difficult to control of the seafood poisonings. To facilitate monitoring of fish toxicity, toxin profiles were investigated by an LC/MS/MS method using 14 reference toxins on eight representative species of fish collected in four different areas of the Pacific. Snappers and groupers from Okinawa contained ciguatoxin-1B (CTX1B) and two deoxy congeners at variable but species-specific ratios, while red snapper, Lutjanus bohar, from Minamitorishima, and amberjack, Seriola dumerili, from Hawaii, contained both CTX1B-type and CTX3C-type toxins. Spotted knifejaw, Oplegnathus punctatus, from Okinawan waters, contained mainly CTX4A and CTX4B, but the same species caught at Miyazaki was contaminated primarily with the CTX3C-type toxins. Otherwise, the toxin profiles were consistently species-specific in fish collected from various locations around Okinawa over 20 years. The LC/MS/MS and mouse bioassay results agreed well, indicating the LC/MS/MS method is a promising alternative to the mouse bioassay. Pure CTX1B and CTX3C were prepared for use in future LC/MS/MS analysis.

  8. LC-MS-MS analysis of 2,4-dinitrophenol and its phase I and II metabolites in a case of fatal poisoning.

    PubMed

    Politi, Lucia; Vignali, Claudia; Polettini, Aldo

    2007-01-01

    A liquid chromatography-tandem mass spectrometry (LC-MS-MS) analysis of biological fluids (blood, urine, gastric content, and bile) collected at autopsy in a case of suspected 2,4-dinitrophenol (DNP) fatal poisoning allowed the determination of DNP and its known metabolites (2-amino-4-nitrophenol and nitro-4-aminophenol). The tentative identification of three conjugated metabolites (DNP glucuronide, DNP sulfate, and 2-amino-4-nitrophenol glucuronide) could be made on the basis of their pseudomolecular ion, isotopic and fragmentation patterns, and retention characteristics. Another DNP metabolite reported in the literature, 2,4-diaminophenol, was not detected in the samples. Postmortem blood concentrations were 48.4 mg/L for DNP and 1.2 mg/L for 2-amino-4-nitrophenol. Gas chromatography-MS screening and quantification in postmortem blood revealed the presence of toxic concentrations of citalopram and its desmethylated metabolite (0.58 and 0.40 mg/L, respectively) and therapeutic or lower than therapeutic levels of olanzapine (0.04 mg/L), desalkylflurazepam (0.02 mg/L), and nordazepam (0.01 mg/L). Based on LC-MS-MS results and on available literature data on DNP poisonings, it was concluded that DNP poisoning played a contributing role, together with citalopram, in the cause of death.

  9. Biotransformation and detectability of the new psychoactive substances N,N-diallyltryptamine (DALT) derivatives 5-fluoro-DALT, 7-methyl-DALT, and 5,6-methylenedioxy-DALT in urine using GC-MS, LC-MSn, and LC-HR-MS/MS.

    PubMed

    Michely, Julian A; Brandt, Simon D; Meyer, Markus R; Maurer, Hans H

    2017-02-01

    Derivatives of N,N-diallyltryptamine (DALT) can be classified as new psychoactive substances. Biotransformation and detectability of 5-fluoro-DALT (5-F-DALT), 7-methyl-DALT (7-Me-DALT), and 5,6-methylenedioxy-DALT (5,6-MD-DALT) are described here. Their metabolites detected in rat urine and pooled human liver microsomes were identified by liquid chromatography (LC)-high resolution (HR)-tandem mass spectrometry (MS/MS). In addition, the human cytochrome-P450 (CYP) isoenzymes involved in the main metabolic steps were identified and detectability tested in urine by the authors' urine screening approaches using GC-MS, LC-MS n , or LC-HR-MS/MS. Aromatic and aliphatic hydroxylations, N-dealkylation, N-oxidation, and combinations could be proposed for all compounds as main pathways. Carboxylation after initial hydroxylation of the methyl group could also be detected for 7-Me-DALT and O-demethylenation was observed for 5,6-MD-DALT. All phase I metabolites were extensively glucuronidated or sulfated. Initial phase I reactions were catalyzed by CYP1A2, CYP2B6, CYP2C9, CYP2C19, CYP2D6, CYP3A4, and CYP3A5. Rat urine samples were analyzed following two different low-dose administrations. GC-MS was not able to monitor consumption reliably, but all three compounds are predicted to be detectable in cases of overdose. The LC-MS n and LC-HR-MS/MS approaches were suitable for detecting an intake of all three compounds mainly via their metabolites. However, after the lowest dose, a reliable monitoring could only be achieved for 5-F-DALT via LC-MS n and LC-HR-MS/MS and for 7-Me-DALT via LC-HR-MS/MS. The most abundant targets in both LC-MS screenings were one of two hydroxy-aryl metabolites and both corresponding glucuronides for 5-F-DALT, one N-deallyl hydroxy-aryl, the carboxy, and one dihydroxy-aryl metabolite for 7-Me-DALT, and the demethylenyl metabolite, its oxo metabolite, and glucuronide for 5,6-MD-DALT.

  10. Certification of NIST standard reference material 2389a, amino acids in 0.1 mol/L HCl--quantification by ID LC-MS/MS.

    PubMed

    Lowenthal, Mark S; Yen, James; Bunk, David M; Phinney, Karen W

    2010-05-01

    An isotope-dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS) measurement procedure was developed to accurately quantify amino acid concentrations in National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 2389a-amino acids in 0.1 mol/L hydrochloric acid. Seventeen amino acids were quantified using selected reaction monitoring on a triple quadrupole mass spectrometer. LC-MS/MS results were compared to gravimetric measurements from the preparation of SRM 2389a-a reference material developed at NIST and intended for use in intra-laboratory calibrations and quality control. Quantitative mass spectrometry results and gravimetric values were statistically combined into NIST-certified mass fraction values with associated uncertainty estimates. Coefficients of variation (CV) for the repeatability of the LC-MS/MS measurements among amino acids ranged from 0.33% to 2.7% with an average CV of 1.2%. Average relative expanded uncertainty of the certified values including Types A and B uncertainties was 3.5%. Mean accuracy of the LC-MS/MS measurements with gravimetric preparation values agreed to within |1.1|% for all amino acids. NIST SRM 2389a will be available for characterization of routine methods for amino acid analysis and serves as a standard for higher-order measurement traceability. This is the first time an ID LC-MS/MS methodology has been applied for quantifying amino acids in a NIST SRM material.

  11. Dried blood spot analysis of creatinine with LC-MS/MS in addition to immunosuppressants analysis.

    PubMed

    Koster, Remco A; Greijdanus, Ben; Alffenaar, Jan-Willem C; Touw, Daan J

    2015-02-01

    In order to monitor creatinine levels or to adjust the dosage of renally excreted or nephrotoxic drugs, the analysis of creatinine in dried blood spots (DBS) could be a useful addition to DBS analysis. We developed a LC-MS/MS method for the analysis of creatinine in the same DBS extract that was used for the analysis of tacrolimus, sirolimus, everolimus, and cyclosporine A in transplant patients with the use of Whatman FTA DMPK-C cards. The method was validated using three different strategies: a seven-point calibration curve using the intercept of the calibration to correct for the natural presence of creatinine in reference samples, a one-point calibration curve at an extremely high concentration in order to diminish the contribution of the natural presence of creatinine, and the use of creatinine-[(2)H3] with an eight-point calibration curve. The validated range for creatinine was 120 to 480 μmol/L (seven-point calibration curve), 116 to 7000 μmol/L (1-point calibration curve), and 1.00 to 400.0 μmol/L for creatinine-[(2)H3] (eight-point calibration curve). The precision and accuracy results for all three validations showed a maximum CV of 14.0% and a maximum bias of -5.9%. Creatinine in DBS was found stable at ambient temperature and 32 °C for 1 week and at -20 °C for 29 weeks. Good correlations were observed between patient DBS samples and routine enzymatic plasma analysis and showed the capability of the DBS method to be used as an alternative for creatinine plasma measurement.

  12. Mycotoxin Analysis of Human Urine by LC-MS/MS: A Comparative Extraction Study

    PubMed Central

    Escrivá, Laura; Font, Guillermina

    2017-01-01

    The lower mycotoxin levels detected in urine make the development of sensitive and accurate analytical methods essential. Three extraction methods, namely salting-out liquid–liquid extraction (SALLE), miniQuEChERS (quick, easy, cheap, effective, rugged, and safe), and dispersive liquid–liquid microextraction (DLLME), were evaluated and compared based on analytical parameters for the quantitative LC-MS/MS measurement of 11 mycotoxins (AFB1, AFB2, AFG1, AFG2, OTA, ZEA, BEA, EN A, EN B, EN A1 and EN B1) in human urine. DLLME was selected as the most appropriate methodology, as it produced better validation results for recovery (79–113%), reproducibility (RSDs < 12%), and repeatability (RSDs < 15%) than miniQuEChERS (71–109%, RSDs <14% and <24%, respectively) and SALLE (70–108%, RSDs < 14% and < 24%, respectively). Moreover, the lowest detection (LODS) and quantitation limits (LOQS) were achieved with DLLME (LODs: 0.005–2 μg L−1, LOQs: 0.1–4 μg L−1). DLLME methodology was used for the analysis of 10 real urine samples from healthy volunteers showing the presence of ENs B, B1 and A1 at low concentrations. PMID:29048356

  13. Characterisation of the ester-substituted products of the reaction of p-t-butyl calix[4]arene and ethyl bromoacetate using LC-UV-MS and LC-DAD.

    PubMed

    McMahon, Gillian; Wall, Rachel; Nolan, Kieran; Diamond, Dermot

    2002-07-19

    A series of derivatisation reactions between p-t-butyl calix[4]arene and ethyl bromoacetate were carried out in order to prepare 1,3 diester substituted calix[4]arene. Mass spectral data, obtained from direct injection of samples, indicated that the reactions were rich in the desired product. Since the ultra violet (UV) spectra of the desired product and possible impurities are very similar, liquid chromatography (LC) chromatographic data seemed to corroborate these results. However, when on-line LC-UV-MS was carried out and each LC peak subjected to MS analysis as it eluted, a very different picture emerged. It was found that many of these reactions actually contained high levels of the monoester product which, having less affinity for sodium in the MS, is therefore seriously underestimated in any direct injection assay. LC-diode array detection (DAD) methods were also used to help successfully identify and characterise the compounds being formed in these complex reactions. The overall results obtained in this paper allowed the optimal reaction conditions to be determined for this reaction. LC-MS analysis of the chromatographic peaks also identified the presence of two isomers of the diester substituted calix[4]arene (1,3 and 1,2 diesters). The combination of LC and UV/MS detection is required for accurate analysis of the products of such reactions.

  14. Identification of alkyl dimethylbenzylammonium surfactants in water samples by solid-phase extraction followed by ion trap LC/MS and LC/MS/MS

    USGS Publications Warehouse

    Ferrer, I.; Furlong, E.T.

    2001-01-01

    A novel methodology was developed for the determination of alkyl (C12, C14, and C16) dimethylbenzylammonium chloride (benzalkonium chloride or BAC, Chemical Abstract Service number: 8001-54-5) in water samples. This method is based on solid-phase extraction (SPE) using polymeric cartridges, followed by high-performance liquid chromatography/ion trap mass spectrometry (LC/MS) and tandem mass spectrometry(MS/MS) detection, equipped with an electrospray interface in positive ion mode. Chromatographic separation was achieved for three BAC homologues by using a C18 column and a gradient of acetonitrile/10 millimolar aqueous ammonium formate. Total method recoveries were higher than 71% in different water matrices. The main ions observed by LC/MS were at mass-to-charge ratios (m/z) of 304, 332, and 360, which correspond to the molecular ions of the C12, C14, and C16 alkyl BAC, respectively. The unequivocal structural identification of these compounds in water samples was performed by LC/MS/MS after isolation and subsequent fragmentation of each molecular ion. The main fragmentation observed for the three different homologues corresponded to the loss of the toluyl group in the chemical structure, which leads to the fragment ions at m/z 212, 240, and 268 and a tropylium ion, characteristic of all homologues, at m/z 91. Detection limits for the methodology developed in this work were in the low nanogram-per-liter range. Concentration levels of BAC - ranging from 1.2 to 36.6 micrograms per liter - were found in surface-water samples collected downstream from different wastewater-treatment discharges, thus indicating its input and persistence through the wastewater-treatment process.

  15. Quantitative analysis of polyethylene glycol (PEG) and PEGylated proteins in animal tissues by LC-MS/MS coupled with in-source CID.

    PubMed

    Gong, Jiachang; Gu, Xiaomei; Achanzar, William E; Chadwick, Kristina D; Gan, Jinping; Brock, Barry J; Kishnani, Narendra S; Humphreys, W Griff; Iyer, Ramaswamy A

    2014-08-05

    The covalent conjugation of polyethylene glycol (PEG, typical MW > 10k) to therapeutic peptides and proteins is a well-established approach to improve their pharmacokinetic properties and diminish the potential for immunogenicity. Even though PEG is generally considered biologically inert and safe in animals and humans, the slow clearance of large PEGs raises concerns about potential adverse effects resulting from PEG accumulation in tissues following chronic administration, particularly in the central nervous system. The key information relevant to the issue is the disposition and fate of the PEG moiety after repeated dosing with PEGylated proteins. Here, we report a novel quantitative method utilizing LC-MS/MS coupled with in-source CID that is highly selective and sensitive to PEG-related materials. Both (40K)PEG and a tool PEGylated protein (ATI-1072) underwent dissociation in the ionization source of mass spectrometer to generate a series of PEG-specific ions, which were subjected to further dissociation through conventional CID. To demonstrate the potential application of the method to assess PEG biodistribution following PEGylated protein administration, a single dose study of ATI-1072 was conducted in rats. Plasma and various tissues were collected, and the concentrations of both (40K)PEG and ATI-1072 were determined using the LC-MS/MS method. The presence of (40k)PEG in plasma and tissue homogenates suggests the degradation of PEGylated proteins after dose administration to rats, given that free PEG was absent in the dosing solution. The method enables further studies for a thorough characterization of disposition and fate of PEGylated proteins.

  16. Determination of nucleoside analog mono-, di-, and tri-phosphates in cellular matrix by solid phase extraction and ultra-sensitive LC-MS/MS detection.

    PubMed

    Bushman, Lane R; Kiser, Jennifer J; Rower, Joseph E; Klein, Brandon; Zheng, Jia-Hua; Ray, Michelle L; Anderson, Peter L

    2011-09-10

    An ultra-sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) assay was developed and validated to facilitate the assessment of clinical pharmacokinetics of nucleotide analogs from lysed intracellular matrix. The method utilized a strong anion exchange isolation of mono-(MP), di-(DP), and tri-phosphates (TP) from intracellular matrix. Each fraction was then dephosphorylated to the parent moiety yielding a molar equivalent to the original nucleotide analog intracellular concentration. The analytical portion of the methodology was optimized in specific nucleoside analog centric modes (i.e. tenofovir (TFV) centric, zidovudine (ZDV) centric), which included desalting/concentration by solid phase extraction and detection by LC-MS/MS. Nucleotide analog MP-, DP-, and TP-determined on the TFV centric mode of analysis include TFV, lamivudine (3TC), and emtricitibine (FTC). The quantifiable linear range for TFV was 2.5-2000 fmol/sample, and that for 3TC/FTC was 0.1 200 pmol/sample. Nucleoside analog MP-, DP-, and TP-determined on the ZDV centric mode of analysis included 3TC and ZDV. The quantifiable linear range for 3TC was 0.1 100 pmol/sample, and 5-2000 fmol/sample for ZDV. Stable labeled isotopic internal standards facilitated accuracy and precision in alternative cell matrices, which supported the intended use of the method for MP, DP, and TP determinations in various cell types. The method was successfully applied to clinical research samples generating novel intracellular information for TFV, FTC, ZDV, and 3TC nucleotides. This document outlines method development, validation, and application to clinical research. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Comparative Analysis of Serum Proteins from Patients with Severe and Mild EV-A71-induced HFMD using iTRAQ-Coupled LC-MS/MS Screening.

    PubMed

    Fan, Peihu; Chen, Wei; Yu, Pin; Bao, Linlin; Xu, Lili; Qin, Chuan

    2017-12-01

    This study was designed to provide a rationale for monitoring the development of severe hand, foot, and mouth disease (HFMD) and predicting the onset of this disease via global comparative analysis between patients with severe and mild HFMD. The authors collected serum from five groups: mild (E-M) and severe (E-S) EV-A71-induced HFMD; mild (NE-M) and severe (NE-S) non-EV-A71-induced HFMD; and healthy control subjects (CON). The authors then performed comparative analysis and identified specific differentially expressed proteins (DEPs) of E-S using isobaric mass tag (isobaric tags for relative and absolute quantitation, iTRAQ) labeling coupled with multidimensional liquid chromatography-mass spectrometry (LC-MS/MS). Moreover, The authors validated specific DEPs by multiple reaction monitoring (MRM). The authors identified 10 specific proteins that were significantly altered in E-S patients. Bioinformatics analysis revealed that most of these DEPs are primarily involved in the acute response to infection, which was common to all groups. More importantly, up-regulated proteins associated with neural injury were specifically identified in the E-S group. These findings conclude that severe HFMD symptoms may be caused by EV-A71 infection-mediated injury of the neural system and provide a reference for future research on the course and prognosis of severe HFMD. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Metabolic profiling of Vitex agnus castus leaves, fruits and sprouts: analysis by LC/ESI/(QqQ)MS and (HR) LC/ESI/(Orbitrap)/MS n.

    PubMed

    Mari, Angela; Montoro, Paola; D'Urso, Gilda; Macchia, Mario; Pizza, Cosimo; Piacente, Sonia

    2015-01-01

    Food supplements based on Vitex agnus castus L. (Verbenaceae) fruits, also known as chasteberry, are routinely used by women against somatic and psychic premenstrual symptoms such as depression, sadness or irritability. With the aim of highlighting the differences in the chemical profiles of cultivated fruits and different parts of wild plants (fruits, leaves and sprouts) of V. agnus castus, a method concerning with the quali-quantitative study of the derived hydroalcoholic extracts was carried out by using high-performance liquid chromatography coupled to electrospray negative ionization Orbitrap multicollisional high resolution mass spectrometry (LC/ESI/(Orbitrap)MS(n)) and high-performance liquid chromatography coupled to electrospray negative ionization triple quadrupole tandem mass spectrometry (LC/ESI/(QqQ)MS) in multiple reaction monitoring (MRM) mode. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Simultaneous determination of rhamnose, xylitol, arabitol, fructose, glucose, inositol, sucrose, maltose in jujube (Zizyphus jujube Mill.) extract: comparison of HPLC-ELSD, LC-ESI-MS/MS and GC-MS.

    PubMed

    Sun, Shihao; Wang, Hui; Xie, Jianping; Su, Yue

    2016-01-01

    Jujube extract is commonly used as a food additive and flavoring. The sensory properties of the extract, especially sweetness, are a critical factor determining the product quality and therefore affecting consumer acceptability. Small molecular carbohydrates make major contribution to the sweetness of the jujube extract, and their types and contents in the extract have direct influence on quality of the product. So, an appropriate qualitative and quantitative method for determination of the carbohydrates is vitally important for quality control of the product. High performance liquid chromatography-evaporative light scattering detection (HPLC-ELSD), liquid chromatography-electronic spay ionization tandem mass spectrometry (LC-ESI-MS/MS), and gas chromatography-mass spectrometry (GC-MS) methods have been developed and applied to determining small molecular carbohydrates in jujube extract, respectively. Eight sugars and alditols were identified from the extract, including rhamnose, xylitol, arabitol, fructose, glucose, inositol, sucrose, and maltose. Comparisons were carried out to investigate the performance of the methods. Although the methods have been found to perform satisfactorily, only three sugars (fructose, glucose and inositol) could be detected by all these methods. Meanwhile, a similar quantitative result for the three sugars can be obtained by the methods. Eight sugars and alditols in the jujube extract were determined by HPLC-ELSD, LC-ESI-MS/MS and GC-MS, respectively. The LC-ELSD method and the LC-ESI-MS/MS method with good precision and accuracy were suitable for quantitative analysis of carbohydrates in jujube extract; although the performance of the GC-MS method for quantitative analysis was inferior to the other methods, it has a wider scope in qualitative analysis. A multi-analysis technique should be adopted in order to obtain complete constituents of about the carbohydrates in jujube extract, and the methods should be employed according to the

  20. ESI-MS, ESI-MS/MS fingerprint and LC-ESI-MS analysis of proathocyanidins from Bursera simaruba Sarg bark.

    PubMed

    Maldini, Mariateresa; Montoro, Paola; Piacente, Sonia; Pizza, Cosimo

    2009-12-01

    Direct flow injection/electrospray ionization/ion trap tandem mass spectrometry was used to investigate the presence of proanthocyanidins (PAs) in the methanolic extract of B. simaruba bark. Additionally, an LC-ESI-MS qualitative study was performed by using a monolithic stationary phase. The fragmentation pattern obtained evidenced the presence in B. simaruba bark of PAs belonging to the series of polymers of epicatechin, along with their glycosilated derivatives.

  1. Identification of RIP-II toxins by affinity enrichment, enzymatic digestion and LC-MS.

    PubMed

    Fredriksson, Sten-Åke; Artursson, Elisabet; Bergström, Tomas; Östin, Anders; Nilsson, Calle; Åstot, Crister

    2015-01-20

    Type 2 ribosome-inactivating protein toxins (RIP-II toxins) were enriched and purified prior to enzymatic digestion and LC-MS analysis. The enrichment of the RIP-II family of plant proteins, such as ricin, abrin, viscumin, and volkensin was based on their affinity for galactosyl moieties. A macroporous chromatographic material was modified with a galactose-terminated substituent and packed into miniaturized columns that were used in a chromatographic system to achieve up to 1000-fold toxin enrichment. The galactose affinity of the RIP-II proteins enabled their selective enrichment from water, beverages, and extracts of powder and wipe samples. The enriched fractions were digested with trypsin and RIP-II peptides were identified based on accurate mass LC-MS data. Their identities were unambiguously confirmed by LC-MS/MS product ion scans of peptides unique to each of the toxins. The LC-MS detection limit achieved for ricin target peptides was 10 amol and the corresponding detection limit for the full method was 10 fmol/mL (0.6 ng/mL). The affinity enrichment method was applied to samples from a forensic investigation into a case involving the illegal production of ricin and abrin toxins.

  2. A Probabilistic Framework for Peptide and Protein Quantification from Data-Dependent and Data-Independent LC-MS Proteomics Experiments

    PubMed Central

    Richardson, Keith; Denny, Richard; Hughes, Chris; Skilling, John; Sikora, Jacek; Dadlez, Michał; Manteca, Angel; Jung, Hye Ryung; Jensen, Ole Nørregaard; Redeker, Virginie; Melki, Ronald; Langridge, James I.; Vissers, Johannes P.C.

    2013-01-01

    A probability-based quantification framework is presented for the calculation of relative peptide and protein abundance in label-free and label-dependent LC-MS proteomics data. The results are accompanied by credible intervals and regulation probabilities. The algorithm takes into account data uncertainties via Poisson statistics modified by a noise contribution that is determined automatically during an initial normalization stage. Protein quantification relies on assignments of component peptides to the acquired data. These assignments are generally of variable reliability and may not be present across all of the experiments comprising an analysis. It is also possible for a peptide to be identified to more than one protein in a given mixture. For these reasons the algorithm accepts a prior probability of peptide assignment for each intensity measurement. The model is constructed in such a way that outliers of any type can be automatically reweighted. Two discrete normalization methods can be employed. The first method is based on a user-defined subset of peptides, while the second method relies on the presence of a dominant background of endogenous peptides for which the concentration is assumed to be unaffected. Normalization is performed using the same computational and statistical procedures employed by the main quantification algorithm. The performance of the algorithm will be illustrated on example data sets, and its utility demonstrated for typical proteomics applications. The quantification algorithm supports relative protein quantification based on precursor and product ion intensities acquired by means of data-dependent methods, originating from all common isotopically-labeled approaches, as well as label-free ion intensity-based data-independent methods. PMID:22871168

  3. Pharmacokinetic Evaluation of Empagliflozin in Healthy Egyptian Volunteers Using LC-MS/MS and Comparison with Other Ethnic Populations.

    PubMed

    Ayoub, Bassam M; Mowaka, Shereen; Elzanfaly, Eman S; Ashoush, Nermeen; Elmazar, Mohamed M; Mousa, Shaker A

    2017-05-31

    The present study considered the pharmacokinetic evaluation of empagliflozin after administration to Egyptian volunteers, and the results were compared with other ethnic populations. The FDA recognizes that standard methods of defining racial subgroups are necessary to compare results across pharmacokinetic studies and to assess potential subgroup differences. The design of the study was as an open labeled, randomized, one treatment, one period, single dose pharmacokinetic study. The main pharmacokinetic parameters estimated were C max , T max , t 1/2 , elimination rate constant, AUC 0-t and AUC 0-inf . The insignificant difference in pharmacokinetic parameters between Egyptians and white German subjects suggests that no dose adjustment should be considered with administration of 25 mg empagliflozin to Egyptian population. A new LC-MS/MS method was developed and validated, allowing sensitive estimation of empagliflozin (25-600 ng mL -1 ) in human plasma using dapagliflozin as an internal standard (IS). The method was applied successfully on the underlying pharmacokinetic study with enhanced sample preparation that involved liquid-liquid extraction. Multiple Reaction Monitoring (MRM) of the transition pairs of m/z 449.01 to 371.21 for empagliflozin and m/z 407.00 to 328.81 for dapagliflozin (IS) was employed utilizing negative mode Electro Spray Ionization (ESI). The validated LC-MS/MS method is suitable for further toxicodynamic and bioequivalence studies.

  4. Metabolic profile of naringenin in the stomach and colon using liquid chromatography/electrospray ionization linear ion trap quadrupole-Orbitrap-mass spectrometry (LC-ESI-LTQ-Orbitrap-MS) and LC-ESI-MS/MS.

    PubMed

    Orrego-Lagarón, Naiara; Vallverdú-Queralt, Anna; Martínez-Huélamo, Miriam; Lamuela-Raventos, Rosa M; Escribano-Ferrer, Elvira

    2016-02-20

    Several biological activities (antioxidant, anti-inflammatory, anticarcinogenic) are attributed to naringenin (NAR)-a predominant flavonoid of citrus fruit and tomato-despite its low bioavailability after ingestion. NAR undergoes extensive metabolism when crossing the gastrointestinal tract, resulting in enteric, hepatic and microbial metabolites, some of them with recognized beneficial effects on human health. This study sought to provide new insights into the metabolism of NAR in regions of the gastrointestinal tract where it has been less studied: the stomach and colon. With this purpose, liquid chromatography coupled with an electrospray ionization hybrid linear ion trap quadrupole Orbitrap mass spectrometry technique (LC-ESI-LTQ-Orbitrap-MS) was used for an accurate identification of NAR metabolites, and liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) on a triple quadrupole was used for their identification and quantification. The combination of both analytical techniques provided a broader metabolic profile of NAR. As far as we know, this is the first in-depth metabolic profiling study of NAR in the stomach of mice. Three of the metabolites determined using the LC-LTQ-Orbitrap could not be identified by LC-ESI-MS/MS in stomach perfusion samples: apigenin, 3-(4-hydroxyphenyl) propionic acid and phloroglucinol. The number of colonic metabolites determined using the LTQ-Orbitrap-MS was more than twice the number identified by LC-ESI-MS/MS. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Differential protein expression analysis using stable isotope labeling and PQD linear ion trap MS technology.

    PubMed

    Armenta, Jenny M; Hoeschele, Ina; Lazar, Iulia M

    2009-07-01

    An isotope tags for relative and absolute quantitation (iTRAQ)-based reversed-phase liquid chromatography (RPLC)-tandem mass spectrometry (MS/MS) method was developed for differential protein expression profiling in complex cellular extracts. The estrogen positive MCF-7 cell line, cultured in the presence of 17beta-estradiol (E2) and tamoxifen (Tam), was used as a model system. MS analysis was performed with a linear trap quadrupole (LTQ) instrument operated by using pulsed Q dissociation (PQD) detection. Optimization experiments were conducted to maximize the iTRAQ labeling efficiency and the number of quantified proteins. MS data filtering criteria were chosen to result in a false positive identification rate of <4%. The reproducibility of protein identifications was approximately 60%-67% between duplicate, and approximately 50% among triplicate LC-MS/MS runs, respectively. The run-to-run reproducibility, in terms of relative standard deviations (RSD) of global mean iTRAQ ratios, was better than 10%. The quantitation accuracy improved with the number of peptides used for protein identification. From a total of 530 identified proteins (P < 0.001) in the E2/Tam treated MCF-7 cells, a list of 255 proteins (quantified by at least two peptides) was generated for differential expression analysis. A method was developed for the selection, normalization, and statistical evaluation of such datasets. An approximate approximately 2-fold change in protein expression levels was necessary for a protein to be selected as a biomarker candidate. According to this data processing strategy, approximately 16 proteins involved in biological processes such as apoptosis, RNA processing/metabolism, DNA replication/transcription/repair, cell proliferation and metastasis, were found to be up- or down-regulated.

  6. Misleading measures in Vitamin D analysis: A novel LC-MS/MS assay to account for epimers and isobars

    PubMed Central

    2011-01-01

    Background Recently, the accuracies of many commercially available immunoassays for Vitamin D have been questioned. Liquid chromatography tandem mass spectrometry (LC- MS/MS) has been shown to facilitate accurate separation and quantification of the major circulating metabolite 25-hydroxyvitamin-D3 (25OHD3) and 25-hydroxyvitamin-D2 (25OHD2) collectively termed as 25OHD. However, among other interferents, this method may be compromised by overlapping peaks and identical masses of epimers and isobars, resulting in inaccuracies in circulating 25OHD measurements. The aim of this study was to develop a novel LC-MS/MS method that can accurately identify and quantitate 25OHD3 and 25OHD2 through chromatographic separation of 25OHD from its epimers and isobars. Methods A positive ion electrospray ionisation (ESI) LC-MS/MS method was used in the Multiple Reaction Monitoring (MRM) mode for quantification. It involved i) liquid-liquid extraction, ii) tandem columns (a high resolution ZORBAX C18 coupled to an ULTRON chiral, with guard column and inlet filter), iii) Stanozolol-D3 as internal standard, and iv) identification via ESI and monitoring of three fragmentation transitions. To demonstrate the practical usefulness of our method, blood samples were collected from 5 healthy male Caucasian volunteers; age range 22 to 37 years and 25OHD2, 25OHD3 along with co-eluting epimers and analogues were quantified. Results The new method allowed chromatographic separation and quantification of 25OHD2, 25OHD3, along with 25OHD3 epimer 3-epi-25OHD3 and isobars 1-α-hydroxyvitamin-D3 (1αOHD3), and 7-α-hydroxy-4-cholesten-3-one (7αC4). The new assay was capable of detecting 0.25 ng/mL of all analytes in serum. Conclusions To our knowledge, this is the first specific, reliable, reproducible and robust LC-MS/MS method developed for the accurate detection of 25OHD (Vitamin D). The method is capable of detecting low levels of 25OHD3 and 25OHD2 together with chromatographic separation from

  7. LC-ESI-MS/MS and cytotoxic activity of three Pistacia species.

    PubMed

    Kirollos, F N; Elhawary, S S; Salama, O M; Elkhawas, Y A

    2018-01-28

    LC-ESI-MS/MS was used for a comprehensive characterisation of ethanol extract from the leaves of three Pistacia species. After optimisation of the method and the use of the negative ionisation mode, a total of 42 different compounds were identified, of which 22 were tentatively characterised in P. chinensis Bunge, 33 in P. khinjuk stocks and 25 in P. lentiscus L. leaves. Flavonoids, phenolic acids, and their derivatives were the most abundant identified compounds. LC-ESI-MS/MS revealed identification of 15, 18 and 6 not previously detected compounds in P. chinensis Bunge, P. khinjuk Stocks and P. lentiscus L., respectively. The three extracts were also tested for their cytotoxic activities against human PC3 prostate cancer, A549 lung cancer, MCF7 breast cancer and HepG2 liver cancer. Generally, all the extracts have a moderate cytotoxic activity against lung, breast and prostate cancer, with different IC 50 . However, only P. lentiscus L. showed moderate activity against liver cancer.

  8. 2016 ASMS Workshop Review: Next Generation LC/MS: Critical Insights and Future Perspectives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gao, Hongying; Makarov, Alexander; Smith, Richard D.

    The pilot workshop on BNext Generation LC/MS: Critical Insights and Future Perspectives was held on the evening of June 6, 2016 at the 64th ASMS Conference on Mass Spectrometry and Allied Topics held in San Antonio, TX. The workshop, chaired by Hongying Gao (Pfizer), consisted of stimulating talks from distinguished speakers and open discussion among the audience and invited presenters.The objectives of this workshop were to better understand the advances and limitations of current technologies; to exchange perspectives on the next generation LC/MS; and to discuss/debate the features of next generation LC/MS focusing on the following three questions: (1) Whatmore » would the next generation LC/MS look like? (2) How would it change the way we do analysis? and (3) What fundamental issues need to be resolved? A real-world case in the biopharmaceutical industry was presented by Hongying Gao on the needs by industry for LC/MS innovation and technology advancements. The primary invited speakers were Alexander Makarov (Thermo Fisher Scientific) and Richard (Dick) Smith (Pacific Northwest National Laboratory). The open discussions started with Q&A and comments for Alexander Makarov and Dick Smith, followed by insights and perspectives from members of the audience and other invited presenters who shared their thoughts addressing the above questions.« less

  9. Comparison of the Membrane Proteome of Virulent Mycobacterium tuberculosis and the Attenuated Mycobacterium bovis BCG Vaccine Strain by Label-free Quantitative Proteomics

    PubMed Central

    Gunawardena, Harsha P.; Feltcher, Meghan E.; Wrobel, John A.; Gu, Sheng; Braunstein, Miriam; Chen, Xian

    2015-01-01

    The Mycobacterium tuberculosis (MTB) membrane is rich in antigens that are potential targets for diagnostics and the development of new vaccines. To better understand the mechanisms underlying MTB virulence and identify new targets for therapeutic intervention we investigated the differential composition of membrane proteomes between virulent M. tuberculosis H37Rv (MTB) and the Mycobacterium bovis BCG vaccine strain. To compare the membrane proteomes, we used LC-MS/MS analysis in combination with label-free quantitative (LFQ) proteomics, utilizing the area-under-curve (AUC) of the extracted ion chromatograms (XIC) of peptides obtained from m/z and retention time alignment of MS1 features. With this approach, we obtained relative abundance ratios for 2,203 identified membrane-associated proteins in high confidence. Of these proteins, 294 showed statistically significant differences of at least 2 fold, in relative abundance between MTB and BCG membrane fractions. Our comparative analysis detected several proteins associated with known genomic regions of difference between MTB and BCG as being absent, which validated the accuracy of our approach. In further support of our label-free quantitative data, we verified select protein differences by immunoblotting. To our knowledge we have generated the first comprehensive and high coverage profile of comparative membrane proteome changes between virulent MTB and its attenuated relative BCG, which helps elucidate the proteomic basis of the intrinsic virulence of the MTB pathogen. PMID:24093440

  10. Automated saliva processing for LC-MS/MS: Improving laboratory efficiency in cortisol and cortisone testing.

    PubMed

    Antonelli, Giorgia; Padoan, Andrea; Artusi, Carlo; Marinova, Mariela; Zaninotto, Martina; Plebani, Mario

    2016-04-01

    The aim of this study was to implement in our routine practice an automated saliva preparation protocol for quantification of cortisol (F) and cortisone (E) by LC-MS/MS using a liquid handling platform, maintaining the previously defined reference intervals with the manual preparation. Addition of internal standard solution to saliva samples and calibrators and SPE on μ-elution 96-well plate were performed by liquid handling platform. After extraction, the eluates were submitted to LC-MS/MS analysis. The manual steps within the entire process were to transfer saliva samples in suitable tubes, to put the cap mat and transfer of the collection plate to the LC auto sampler. Transference of the reference intervals from the manual to the automated procedure was established by Passing Bablok regression on 120 saliva samples analyzed simultaneously with the two procedures. Calibration curves were linear throughout the selected ranges. The imprecision ranged from 2 to 10%, with recoveries from 95 to 116%. Passing Bablok regression demonstrated no significant bias. The liquid handling platform translates the manual steps into automated operations allowing for saving hands-on time, while maintaining assay reproducibility and ensuring reliability of results, making it implementable in our routine with the previous established reference intervals. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  11. Tramadol chronic abuse: an evidence from hair analysis by LC tandem MS.

    PubMed

    Verri, Patrizia; Rustichelli, Cecilia; Palazzoli, Federica; Vandelli, Daniele; Marchesi, Filippo; Ferrari, Anna; Licata, Manuela

    2015-01-01

    Hair analysis, as complementary matrix, has expanded across the spectrum of toxicological investigations for misuse drug monitoring. Hair has become an important matrix for drug analysis, owing to the possibility to detect target analytes for long time periods, depending on hair length. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed for the quantitation of tramadol, a widely used centrally acting analgesic, and its main metabolites in hair (ODMT, NDMT, NOT). Hair samples were decontaminated and incubated overnight in diluted hydrochloric acid; the extracts were purified by mixed-mode solid phase cartridges and analyzed by LC-MS/MS in positive ionization mode monitoring two transitions per analyte. The procedure was fully validated in terms of linearity, limit of detection and lower limit of quantitation (LLOQ), accuracy, precision, recovery, matrix effect and selectivity. The linear regression analysis was calibrated by deuterated internal standards; for all analytes, responses were linear over the range 0.04-40.00 ng/mg hair, with R(2) values of at least 0.995. The method offered satisfactory precision (RSD < 10%), accuracy (90-110%) and recovery (> 90%) values. The found LLOQ values for tramadol and metabolites were in the range 0.010-0.030 ng/mg hair. The proposed procedure was successfully applied to quantify tramadol and metabolites in real hair samples submitted to our laboratory: three cases of tramadol assumption within the therapeutic dosage (3 × 2 segments) and one case of tramadol abuse in a binge pattern (8 segments). The ranges found for TRAM, ODMT, NDMT and NOT were markedly higher in the abuse case (63.42-107.30, 3.76-6.26, 24.88-45.66, 0.22-1.18 ng/mg hair, respectively) compared to the other case reports (3.29-20.12, 0.28-1.87, 0.45-4.32, 0.07-0.80 ng/mg, respectively); also the values of NMDT/ODMT ratio differed significantly. According to the obtained data, we hypothesized that the binge pattern may

  12. Determination of cocaine and benzoylecgonine in guinea pig's hair after a single dose administration by LC-MS/MS.

    PubMed

    Sun, Qi-ran; Xiang, Ping; Yan, Hui; Shen, Min

    2008-12-01

    A sensitive LC-MS/MS method to determine cocaine and its major metabolite benzoylecgonine in guinea pig' s hair has been established. About 20 mg of decontaminated hair sample was hydrolyzed with 0. 1 mol x L(-1) HCl at 50 degrees C overnight, in the presence of cocaine-d3 and benzoylecgonine-d8 used as internal standards, and then extracted with dichlormethane. The analysis was performed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Positive electrospray ionization (ESI +) and multiple reactions monitoring (MRM) mode were used. The limit of detection (LOD) for cocaine and benzoylecgonine was 1 pg x mg(-1). The calibration curves of extracted standards were linear over the range from 5 pg x mg(-1) to 250 pg x mg(-1) (r2 > or = 0.9997). The method was validated and applied to the analysis of guinea pig's hair after a single dose administration of cocaine hydrochloride. Cocaine and benzoylecgonine were not only detected, but also quantified in guinea pigs hair.

  13. Microwave-assisted extraction and quantitative LC/ID-MS measurement of total choline and free carnitine in food standard reference materials.

    PubMed

    Phillips, Melissa M; Sander, Lane C

    2012-01-01

    The Stakeholder Panel on Infant Formula and Adult Nutritionals of AOAC INTERNATIONAL has declared both choline and carnitine to be priority nutrients in infant formulas, and ongoing efforts exist to develop or improve Official Methods of Analysis for these nutrients. As a result, matrix-based certified reference materials are needed with assigned values for these compounds. In this work, traditional acid and enzymatic hydrolysis procedures were compared to microwave-assisted acid hydrolysis, and conditions optimized to provide complete sample hydrolysis and recovery of total choline from four food standard reference materials (SRMs): whole milk powder, whole egg powder, infant formula, and soy flour. The extracts were analyzed using LC on a mixed-mode column (simultaneous RP and ion exchange) with isotope dilution-MS detection to achieve simultaneous quantification of total choline and free carnitine. Total choline has been determined in these four food matrixes with excellent precision (0.65 to 2.60%) and accuracy, as confirmed by use of SRM 1849 Infant/Adult Nutritional Formula as a control material. Free carnitine has been determined in two of these food matrixes with excellent precision (0.69 to 2.19%) and accuracy, as confirmed by use of SRM 1849 Infant/Adult Nutritional Formula as a control material. Limitations in simultaneous determination of total choline and free carnitine resulted from extreme differences in concentration of the two components in egg powder and soy flour (at least three orders of magnitude). Samples required dilution to prevent poor LC peak shape, which caused decreased precision in the determination of low concentrations of free carnitine. Despite this limitation, the described method yields results comparable to current AOAC Official Method 999.14 Choline in Infant Formula, with a decrease of more than 2 h in sample preparation time.

  14. LC-QTOF-MS Analysis and Activity Profiles of Popular Antioxidant Dietary Supplements in Terms of Quality Control

    PubMed Central

    Baj, Tomasz; Sawicki, Rafal; Wanat, Aleksandra; Wojtanowski, Krzysztof Kamil; Ginalska, Grazyna; Zgorka, Grazyna; Szymanska, Jolanta

    2017-01-01

    The dietary supplements with claimed antioxidant activity constitute a substantial part of the dietary supplement market. In this study, we performed the LC-QTOF-MS analysis and investigated the activity profiles of popular antioxidant dietary supplements from different chemical groups in terms of quality control. The commonly used antioxidant tests and statistical analysis revealed that substantial part of the results was comparable if 1 g sample was considered, but while comparing single and daily doses, significant differences in antioxidant values were noticed in all assays. The best antioxidant activity was obtained in ORAC assay (from 142 to 13814 μM of Trolox equivalents per 1 g of sample), and the strongest correlation occurred between TPC and ORAC. The LC-QTOF-MS analysis revealed that catechins were present in samples having the best antioxidant activity and that dietary supplements showing the weakest activity contained very small amount of any chemical constituents. PMID:28642814

  15. Evaluation of peptide adsorption-controlled liquid chromatography-tandem mass spectrometric (PAC-LC-MS/MS) method for simple and simultaneous quantitation of amyloid β 1-38, 1-40, 1-42 and 1-43 peptides in dog cerebrospinal fluid.

    PubMed

    Goda, Ryoya; Kobayashi, Nobuhiro

    2012-05-01

    To evaluate the usefulness of the peptide adsorption-controlled liquid chromatography-tandem mass spectrometry (PAC-LC-MS/MS) for reproducible measurement of peptides in biological fluids, simultaneous quantitation of amyloid β 1-38, 1-40, 1-42 and 1-43 peptides (Aβ38, Aβ40, Aβ42 and Aβ43) in dog cerebrospinal fluid (CSF) was tried. Each stable isotope labeled Aβ was used as the internal standard to minimize the influence of CSF matrix on the reproducible Aβ quantitation. To reduce a loss of Aβ during the pretreatment procedures, the dog CSF diluted by water-acetic acid-methanol (2:6:1, v/v/v) was loaded on PAC-LC-MS/MS directly. Quantification of the Aβ in the diluted dog CSF was carried out using multiple reaction monitoring (MRM) mode. The [M+5H(5+)] and b(5+) ion fragment of each peptide were chosen as the precursor and product ions for MRM transitions of each peptide. The calibration curves were drawn from Aβ standard calibration solutions using PAC-LC-MS/MS. Analysis of dog CSF samples suggests that the basal concentration of Aβ38, Aβ40, Aβ42 and Aβ43 in dog CSF is approximately 300, 900, 200 and 30 pM, respectively. This is the first time Aβ concentrations in dog CSF have been reported. Additionally, the evaluation of intra- and inter-day reproducibility of analysis of Aβ standard solution, the freeze-thaw stability and the room temperature stability of Aβ standard solution suggest that the PAC-LC-MS/MS method enables reproducible Aβ quantitation. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Evaluation of tamoxifen and metabolites by LC-MS/MS and HPLC methods.

    PubMed

    Heath, D D; Flat, S W; Wu, A H B; Pruitt, M A; Rock, C L

    2014-01-01

    Epidemiological and laboratory evidence suggests that quantification of serum or plasma levels of tamoxifen and its metabolites, 4-hydroxy-N-desmethyl-tamoxifen (endoxifen), Z-4-hydroxytamoxifen (4HT), N-desmethyl-tamoxifen (ND-tam), is a clinically useful tool in the assessment and monitoring of breast cancer status in patients taking adjuvant tamoxifen. A liquid chromatographic mass spectrometric method (LC-MS/MS) was used to measure the blood levels of tamoxifen and its metabolites. This fully automated analytical method is specific, accurate and sensitive. The LC-MS/MS automated technique has now become a widely accepted reference method. This study analysed a randomly selected batch of blood samples from participants enrolled in a breast cancer study to compare results from this reference method in 40 samples with those obtained from a recently developed high-performance liquid chromatography (HPLC) method with fluorescence detection. The mean (SD) concentrations for the LC-MS/MS method (endoxifen 12.6 [7.5] ng/mL, tamoxifen 105 [44] ng/mL, 4-HT 1.9 [1.0] ng/mL, ND-tam 181 [69] ng/mL) and the HPLC method (endoxifen 13.1 [7.8] ng/mL, tamoxifen 108 [55] ng/mL, 4-HT 1.8 [0.8] ng/mL, ND-tam 184 [81] ng/mL) did not show any significant differences. The results confirm that the HPLC method offers an accurate and comparable alternative for the quantification of tamoxifen and tamoxifen metabolites.

  17. Antioxidant properties and phenolic profile characterization by LC-MS/MS of selected Tunisian pomegranate peels.

    PubMed

    Abid, Mouna; Yaich, Héla; Cheikhrouhou, Salma; Khemakhem, Ibtihel; Bouaziz, Mohamed; Attia, Hamadi; Ayadi, M A

    2017-08-01

    Antioxidant contents and activities of different extracts from four Tunisian pomegranate peels, locally called "Acide", "Gabsi", "Nebli" and "Tounsi", were studied. Peels samples were extracted with three solvents (water, ethanol and acetone). For each extract, the total phenol contents and antioxidant activity were evaluated. The highest values of polyphenol, tannins, flavonoids and anthocyanins were recorded in the acetone extract of Acide ecotype with 304.6 mg gallic acid equivalent/g; 292.23 mg gallic acid equivalent/g; 15.46 mg Quercetin/g and 54.51 mg cy-3-glu/100 g, respectively. The acetone extract of Acide ecotype also showed the highest free radical-scavenging and reducing power activity compared to other extracts. Besides, the phytochemical analysis by LC-MS/MS revealed a high content of ellagitannins with punicalagin and punicalagin derivatives as the major compounds that might be responsible for promising antioxidant activity of pomegranate peel extracts. Two compounds (Castalagin derivative and Galloyl-bis-HHDP-hex derivative) were detected only in "Acide" ecotype in important contents.

  18. Evaluation of various QuEChERS based methods for the analysis of herbicides and other commonly used pesticides in polished rice by LC-MS/MS.

    PubMed

    Pareja, Lucía; Cesio, Verónica; Heinzen, Horacio; Fernández-Alba, Amadeo R

    2011-02-15

    Four different extraction and clean-up protocols based on the QuEChERS method were compared for the development of an optimized sample preparation procedure for the multiresidue analysis of 16 commonly applied herbicides in rice crops using LC-QqQ/MS. Additionally the methods were evaluated for the analysis of 26 insecticides and fungicides currently used in rice crops. The methods comprise, in general, the hydratation of the sample with water followed by the extraction with acetonitrile, phase separation with the addition of different salts and finally a clean-up step with various sorbents. Matrix effects were evaluated for the 4 studied methods using LC-QqQ/MS. Additionally LC-TOF/MS was used to compare the co-extractants obtained with the four assayed methodologies. Thirty-six pesticides presented good performance with recoveries in the range 70-120% and relative standard deviations below 20% using 7.5 g of milled polished rice and the buffered acetate QuEChERS method without clean-up at both fortification levels: 10 and 300 μg kg(-1). The other six pesticides presented low recovery rates, nevertheless all these analytes could be analyzed with at least one of the other three studied procedures. Copyright © 2010. Published by Elsevier B.V.

  19. LC-MS/MS based identification of piperine production by endophytic Mycosphaerella sp. PF13 from Piper nigrum.

    PubMed

    Chithra, S; Jasim, B; Anisha, C; Mathew, Jyothis; Radhakrishnan, E K

    2014-05-01

    Piper nigrum is very remarkable for its medicinal properties due to the presence of metabolites like piperine. Emerging understanding on the biosynthetic potential of endophytic fungi suggests the possibility to have piperine producing fungi in P. nigrum. In the current study, endophytic fungi isolated from P. nigrum were screened for the presence of piperine by liquid chromatography-tandem mass spectrometry (LC-MS/MS). This resulted in the identification of a Mycosphaerella sp. with the ability to produce piperine extracellularly. The biosynthesis of piperine (C17H19NO3) by the endophytic fungal isolate was confirmed by the presence of m/z 286.1 (M + H(+)) in the LC-MS/MS analysis using positive mode ionization. This was further supported by the presence of specific fragment ions with masses 135, 143, 171 and 201 formed due to the fragmentation of piperine present in the fungal extract.

  20. Evaluation of Normalization Methods to Pave the Way Towards Large-Scale LC-MS-Based Metabolomics Profiling Experiments

    PubMed Central

    Valkenborg, Dirk; Baggerman, Geert; Vanaerschot, Manu; Witters, Erwin; Dujardin, Jean-Claude; Burzykowski, Tomasz; Berg, Maya

    2013-01-01

    Abstract Combining liquid chromatography-mass spectrometry (LC-MS)-based metabolomics experiments that were collected over a long period of time remains problematic due to systematic variability between LC-MS measurements. Until now, most normalization methods for LC-MS data are model-driven, based on internal standards or intermediate quality control runs, where an external model is extrapolated to the dataset of interest. In the first part of this article, we evaluate several existing data-driven normalization approaches on LC-MS metabolomics experiments, which do not require the use of internal standards. According to variability measures, each normalization method performs relatively well, showing that the use of any normalization method will greatly improve data-analysis originating from multiple experimental runs. In the second part, we apply cyclic-Loess normalization to a Leishmania sample. This normalization method allows the removal of systematic variability between two measurement blocks over time and maintains the differential metabolites. In conclusion, normalization allows for pooling datasets from different measurement blocks over time and increases the statistical power of the analysis, hence paving the way to increase the scale of LC-MS metabolomics experiments. From our investigation, we recommend data-driven normalization methods over model-driven normalization methods, if only a few internal standards were used. Moreover, data-driven normalization methods are the best option to normalize datasets from untargeted LC-MS experiments. PMID:23808607

  1. Proteomic analysis of protein interactions between Eimeria maxima sporozoites and chicken jejunal epithelial cells by shotgun LC-MS/MS.

    PubMed

    Huang, Jingwei; Liu, Tingqi; Li, Ke; Song, Xiaokai; Yan, Ruofeng; Xu, Lixin; Li, Xiangrui

    2018-04-04

    Eimeria maxima initiates infection by invading the jejunal epithelial cells of chicken. However, the proteins involved in invasion remain unknown. The research of the molecules that participate in the interactions between E. maxima sporozoites and host target cells will fill a gap in our understanding of the invasion system of this parasitic pathogen. In the present study, chicken jejunal epithelial cells were isolated and cultured in vitro. Western blot was employed to analyze the soluble proteins of E. maxima sporozoites that bound to chicken jejunal epithelial cells. Co-immunoprecipitation (co-IP) assay was used to separate the E. maxima proteins that bound to chicken jejunal epithelial cells. Shotgun LC-MS/MS technique was used for proteomics identification and Gene Ontology was employed for the bioinformatics analysis. The results of Western blot analysis showed that four proteins bands from jejunal epithelial cells co-cultured with soluble proteins of E. maxima sporozoites were recognized by the positive sera, with molecular weights of 70, 90, 95 and 130 kDa. The co-IP dilutions were analyzed by shotgun LC-MS/MS. A total of 204 proteins were identified in the E. maxima protein database using the MASCOT search engine. Thirty-five proteins including microneme protein 3 and 7 had more than two unique peptide counts and were annotated using Gene Ontology for molecular function, biological process and cellular localization. The results revealed that of the 35 annotated peptides, 22 (62.86%) were associated with binding activity and 15 (42.86%) were involved in catalytic activity. Our findings provide an insight into the interaction between E. maxima and the corresponding host cells and it is important for the understanding of molecular mechanisms underlying E. maxima invasion.

  2. Development of LC-MS/MS method for the simultaneous analysis of the cardioprotective drug dexrazoxane and its metabolite ADR-925 in isolated cardiomyocytes and cell culture medium.

    PubMed

    Kovarikova, Petra; Pasakova-Vrbatova, Ivana; Vavrova, Anna; Stariat, Jan; Klimes, Jiri; Simunek, Tomas

    2013-03-25

    Dexrazoxane (DEX) is the only clinically used drug effective against anthracycline-induced cardiotoxicity and extravasation injury. However, the mechanism of its cardioprotective action still remains elusive. This paucity of comprehensive data is at least partially caused by the analytical difficulties associated with selective and sensitive simultaneous determination of the parent drug and its putative active metabolite ADR-925 in the relevant biological material. The aim of this study was to develop and validate the first LC-MS/MS method for simultaneous determination of DEX and ADR-925 in the isolated rat neonatal ventricular cardiomyocytes (NVCMs) and the cell culture medium. The analysis was performed on a Synergi Polar-RP column using the gradient profile of the mobile phase composed of 2mM ammonium formate and methanol. Electrospray ionization and ion trap mass analyzer were used as ionization and detection techniques, respectively. NVCMs were precipitated with methanol and the cell culture medium samples were diluted with the same solvent prior the LC-MS/MS analysis. The method was validated within the range of 4-80pmol/10(6) NVCMs and 7-70pmol/10(6) NVCMs for DEX and ADR-925, respectively, and at the concentrations of 8-100μM for both compounds in the culture cell medium. The practical applicability of this method was confirmed by the pilot analysis of NVCMs and the corresponding cell medium samples from relevant in vitro experiment. Hence, the LC-MS/MS method developed in this study represents a modern analytical tool suitable for investigation of DEX bioactivation inside the cardiomyocytes. In addition, the basic utility of the method for the analysis of DEX and ADR-925 in plasma samples was proved in a pilot experiment. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Determination of 32 cathinone derivatives and other designer drugs in serum by comprehensive LC-QQQ-MS/MS analysis.

    PubMed

    Swortwood, Madeleine J; Boland, Diane M; DeCaprio, Anthony P

    2013-02-01

    Recently, clandestine drug lab operators have attempted to bypass controlled substances laws and regulations with "designer" compounds chemically and pharmacologically similar to controlled substances. For example, "bath salts" have erupted onto the scene as "legal highs" containing cathinone analogs that have produced severe side effects in users worldwide. These products have sparked concern among law enforcement agencies, and emergency bans have been placed on the sale of such items. Despite the increasing number of designer drugs available, there are few comprehensive screening techniques for their detection and quantification in biological specimens. The liquid chromatography triple quadrupole tandem mass spectrometry (LC-QQQ-MS/MS) method presented here encompasses over thirty important compounds within the phenethylamine, tryptamine, and piperazine designer drug classes. Analytes were determined by LC-QQQ-MS/MS in the multiple-reaction monitoring mode after mixed-mode solid-phase extraction. The bioanalytical method was fully validated according to recommended international guidelines. The assay was selective for all analytes with acceptable accuracy and precision. Limits of quantification were in the range of 1-10 ng/mL for each compound with limits of detection near 10 pg/mL. In order to evaluate its applicability in a forensic toxicological setting, the validated method was used to analyze post-mortem specimens from two cases that were suspected of containing designer drugs. The method was able to identify and quantify seven of these compounds at concentrations as low as 11 ng/mL. The method should have wide applicability for rapid screening of important new drugs of abuse at high sensitivity in both post- and ante-mortem forensic analysis.

  4. Development and validation of sensitive LC-MS/MS assays for quantification of HP-β-CD in human plasma and CSF

    PubMed Central

    Jiang, Hui; Sidhu, Rohini; Fujiwara, Hideji; De Meulder, Marc; de Vries, Ronald; Gong, Yong; Kao, Mark; Porter, Forbes D.; Yanjanin, Nicole M.; Carillo-Carasco, Nuria; Xu, Xin; Ottinger, Elizabeth; Woolery, Myra; Ory, Daniel S.; Jiang, Xuntian

    2014-01-01

    2-Hydroxypropyl-β-cyclodextrin (HP-β-CD), a widely used excipient for drug formulation, has emerged as an investigational new drug for the treatment of Niemann-Pick type C1 (NPC1) disease, a neurodegenerative cholesterol storage disorder. Development of a sensitive quantitative LC-MS/MS assay to monitor the pharmacokinetics (PKs) of HP-β-CD required for clinical trials has been challenging owing to the dispersity of the HP-β-CD. To support a phase 1 clinical trial for ICV delivery of HP-β-CD in NPC1 patients, novel methods for quantification of HP-β-CD in human plasma and cerebrospinal fluid (CSF) using LC-MS/MS were developed and validated: a 2D-LC-in-source fragmentation-MS/MS (2D-LC-IF-MS/MS) assay and a reversed phase ultra performance LC-MS/MS (RP-UPLC-MS/MS) assay. In both assays, protein precipitation and “dilute and shoot” procedures were used to process plasma and CSF, respectively. The assays were fully validated and in close agreement, and allowed determination of PK parameters for HP-β-CD. The LC-MS/MS methods are ∼100-fold more sensitive than the current HPLC assay, and were successfully employed to analyze HP-β-CD in human plasma and CSF samples to support the phase 1 clinical trial of HP-β-CD in NPC1 patients. PMID:24868096

  5. Poly A tail length analysis of in vitro transcribed mRNA by LC-MS.

    PubMed

    Beverly, Michael; Hagen, Caitlin; Slack, Olga

    2018-02-01

    The 3'-polyadenosine (poly A) tail of in vitro transcribed (IVT) mRNA was studied using liquid chromatography coupled to mass spectrometry (LC-MS). Poly A tails were cleaved from the mRNA using ribonuclease T1 followed by isolation with dT magnetic beads. Extracted tails were then analyzed by LC-MS which provided tail length information at single-nucleotide resolution. A 2100-nt mRNA with plasmid-encoded poly A tail lengths of either 27, 64, 100, or 117 nucleotides was used for these studies as enzymatically added poly A tails showed significant length heterogeneity. The number of As observed in the tails closely matched Sanger sequencing results of the DNA template, and even minor plasmid populations with sequence variations were detected. When the plasmid sequence contained a discreet number of poly As in the tail, analysis revealed a distribution that included tails longer than the encoded tail lengths. These observations were consistent with transcriptional slippage of T7 RNAP taking place within a poly A sequence. The type of RNAP did not alter the observed tail distribution, and comparison of T3, T7, and SP6 showed all three RNAPs produced equivalent tail length distributions. The addition of a sequence at the 3' end of the poly A tail did, however, produce narrower tail length distributions which supports a previously described model of slippage where the 3' end can be locked in place by having a G or C after the poly nucleotide region. Graphical abstract Determination of mRNA poly A tail length using magnetic beads and LC-MS.

  6. Investigation of enrofloxacin residues in broiler tissues using ELISA and LC-MS/MS.

    PubMed

    Panzenhagen, Pedro Henrique N; Aguiar, Waldemir S; Gouvêa, Raquel; de Oliveira, Andréa M G; Barreto, Fabiano; Pereira, Virgínia L A; Aquino, Maria Helena C

    2016-01-01

    This study investigated the efficiency of an enrofloxacin ELISA test kit to detect the presence of enrofloxacin residues in broiler tissues compared with LC-MS/MS. Broiler tissues from 72 samples consisting of 60 breast muscle, six pools of livers (500 g each) and six pools of kidneys (500 g each) were obtained from six different slaughterhouses. Breast muscle from 10 carcasses and pools of livers and kidneys from approximately 200 carcasses of the same flock were collected from each slaughterhouse. ELISA and HPLC were used to identify and quantify the contamination of the samples with enrofloxacin. A total of 72% of the analysed samples contained enrofloxacin residues detected by the ELISA and 22.2% were detected by LC-MS/MS. The mean values of enrofloxacin contamination found in chicken breast by ELISA and HPLC were 8.63 and 12.25 μg kg(-1), respectively. None of the samples exceeded the maximum limit of 100 μg kg(-1) by both methods set by the European Union as well as the Brazilian Agriculture Ministry. All positive samples for enrofloxacin residues detected by LC-MS/MS were also positive by ELISA. These data confirm the efficiency of the ELISA test, and suggest its use as a screening method for enrofloxacin residues in poultry tissues due to its quick results, low price and ease of applicability.

  7. Importance of MS selectivity and chromatographic separation in LC-MS/MS-based methods when investigating pharmaceutical metabolites in water. Dipyrone as a case of study.

    PubMed

    Ibáñez, M; Gracia-Lor, E; Sancho, J V; Hernández, F

    2012-08-01

    Pharmaceuticals are emerging contaminants of increasing concern because of their presence in the aquatic environment and potential to reach drinking-water sources. After human and/or veterinary consumption, pharmaceuticals can be excreted in unchanged form, as the parent compound, and/or as free or conjugated metabolites. Determination of most pharmaceuticals and metabolites in the environment is commonly made by liquid chromatography (LC) coupled to mass spectrometry (MS). LC coupled to tandem MS is the technique of choice nowadays in this field. The acquisition of two selected reaction monitoring (SRM) transitions together with the retention time is the most widely accepted criterion for a safe quantification and confirmation assay. However, scarce attention is normally paid to the selectivity of the selected transitions as well as to the chromatographic separation. In this work, the importance of full spectrum acquisition high-resolution MS data using a hybrid quadrupole time-of-flight analyser and/or a suitable chromatographic separation (to reduce the possibility of co-eluting interferences) is highlighted when investigating pharmaceutical metabolites that share common fragment ions. For this purpose, the analytical challenge associated to the determination of metabolites of the widely used analgesic dipyrone (also known as metamizol) in urban wastewater is discussed. Examples are given on the possibilities of reporting false positives of dypirone metabolites by LC-MS/MS under SRM mode due to a wrong assignment of identity of the compounds detected. Copyright © 2012 John Wiley & Sons, Ltd.

  8. Label-Free Relative Quantitation of Isobaric and Isomeric Human Histone H2A and H2B Variants by Fourier Transform Ion Cyclotron Resonance Top-Down MS/MS.

    PubMed

    Dang, Xibei; Singh, Amar; Spetman, Brian D; Nolan, Krystal D; Isaacs, Jennifer S; Dennis, Jonathan H; Dalton, Stephen; Marshall, Alan G; Young, Nicolas L

    2016-09-02

    Histone variants are known to play a central role in genome regulation and maintenance. However, many variants are inaccessible by antibody-based methods or bottom-up tandem mass spectrometry due to their highly similar sequences. For many, the only tractable approach is with intact protein top-down tandem mass spectrometry. Here, ultra-high-resolution FT-ICR MS and MS/MS yield quantitative relative abundances of all detected HeLa H2A and H2B isobaric and isomeric variants with a label-free approach. We extend the analysis to identify and relatively quantitate 16 proteoforms from 12 sequence variants of histone H2A and 10 proteoforms of histone H2B from three other cell lines: human embryonic stem cells (WA09), U937, and a prostate cancer cell line LaZ. The top-down MS/MS approach provides a path forward for more extensive elucidation of the biological role of many previously unstudied histone variants and post-translational modifications.

  9. Effect of Genetics, Environment, and Phenotype on the Metabolome of Maize Hybrids Using GC/MS and LC/MS.

    PubMed

    Tang, Weijuan; Hazebroek, Jan; Zhong, Cathy; Harp, Teresa; Vlahakis, Chris; Baumhover, Brian; Asiago, Vincent

    2017-06-28

    We evaluated the variability of metabolites in various maize hybrids due to the effect of environment, genotype, phenotype as well as the interaction of the first two factors. We analyzed 480 forage and the same number of grain samples from 21 genetically diverse non-GM Pioneer brand maize hybrids, including some with drought tolerance and viral resistance phenotypes, grown at eight North American locations. As complementary platforms, both GC/MS and LC/MS were utilized to detect a wide diversity of metabolites. GC/MS revealed 166 and 137 metabolites in forage and grain samples, respectively, while LC/MS captured 1341 and 635 metabolites in forage and grain samples, respectively. Univariate and multivariate analyses were utilized to investigate the response of the maize metabolome to the environment, genotype, phenotype, and their interaction. Based on combined percentages from GC/MS and LC/MS datasets, the environment affected 36% to 84% of forage metabolites, while less than 7% were affected by genotype. The environment affected 12% to 90% of grain metabolites, whereas less than 27% were affected by genotype. Less than 10% and 11% of the metabolites were affected by phenotype in forage and grain, respectively. Unsupervised PCA and HCA analyses revealed similar trends, i.e., environmental effect was much stronger than genotype or phenotype effects. On the basis of comparisons of disease tolerant and disease susceptible hybrids, neither forage nor grain samples originating from different locations showed obvious phenotype effects. Our findings demonstrate that the combination of GC/MS and LC/MS based metabolite profiling followed by broad statistical analysis is an effective approach to identify the relative impact of environmental, genetic and phenotypic effects on the forage and grain composition of maize hybrids.

  10. Evaluation of Tamoxifen and metabolites by LC-MS/MS and HPLC Methods

    PubMed Central

    Heath, D.D.; Flatt, S.W.; Wu, A.H.B.; Pruitt, M.A.; Rock, C.L.

    2015-01-01

    Epidemiological and laboratory evidence suggests that quantification of serum or plasma levels of tamoxifen and the metabolites of tamoxifen, 4-hydroxy-N-desmethyl-tamoxifen (endoxifen), Z-4-hydroxy-tamoxifen (4HT), N-desmethyl-tamoxifen (ND-tam) is a clinically useful tool in the assessment and monitoring of breast cancer status in patients taking adjuvant tamoxifen. A liquid chromatographic mass spectrometric method (LC-MS/MS) was used to measure the blood levels of tamoxifen and the metabolites of tamoxifen. This fully automated analytical method is specific, accurate and sensitive. The LC-MS/MS automated technique has now become a widely accepted reference method. We analyzed a randomly selected batch of blood samples from participants enrolled in a breast cancer study to compare results from this reference method in 40 samples with those obtained from a recently developed high performance liquid chromatography (HPLC) method with fluorescence detection. The mean (SD) concentration for the LC-MS/MS (endoxifen 12.6 [7.5] ng/mL, tamoxifen 105 [44] ng/mL, 4-HT 1.9 [1.0] ng/mL, ND-tam 181 [69] ng/mL) and the HPLC (endoxifen 13.1 [7.8] ng/mL, tamoxifen 108[55]ng/mL, 4-HT 1.8 [0.8] ng/mL, ND-tam 184 [81] ng/mL), the methods did not show any significant differences. Our results confirm that the HPLC method offers an accurate and comparable alternative for the quantification of tamoxifen and tamoxifen metabolites. PMID:24693573

  11. LC/MS/MS analysis of the endogenous dimethyltryptamine hallucinogens, their precursors, and major metabolites in rat pineal gland microdialysate.

    PubMed

    Barker, Steven A; Borjigin, Jimo; Lomnicka, Izabela; Strassman, Rick

    2013-12-01

    We report a qualitative liquid chromatography-tandem mass spectrometry (LC/MS/MS) method for the simultaneous analysis of the three known N,N-dimethyltryptamine endogenous hallucinogens, their precursors and metabolites, as well as melatonin and its metabolic precursors. The method was characterized using artificial cerebrospinal fluid (aCSF) as the matrix and was subsequently applied to the analysis of rat brain pineal gland-aCSF microdialysate. The method describes the simultaneous analysis of 23 chemically diverse compounds plus a deuterated internal standard by direct injection, requiring no dilution or extraction of the samples. The results demonstrate that this is a simple, sensitive, specific and direct approach to the qualitative analysis of these compounds in this matrix. The protocol also employs stringent MS confirmatory criteria for the detection and confirmation of the compounds examined, including exact mass measurements. The excellent limits of detection and broad scope make it a valuable research tool for examining the endogenous hallucinogen pathways in the central nervous system. We report here, for the first time, the presence of N,N-dimethyltryptamine in pineal gland microdialysate obtained from the rat. Copyright © 2013 John Wiley & Sons, Ltd.

  12. Distinctive and Complementary MS2 Fragmentation Characteristics for Identification of Sulfated Sialylated N-Glycopeptides by nanoLC-MS/MS Workflow

    NASA Astrophysics Data System (ADS)

    Kuo, Chu-Wei; Guu, Shih-Yun; Khoo, Kay-Hooi

    2018-04-01

    High sensitivity identification of sulfated glycans carried on specific sites of glycoproteins is an important requisite for investigation of molecular recognition events involved in diverse biological processes. However, aiming for resolving site-specific glycosylation of sulfated glycopeptides by direct LC-MS2 sequencing is technically most challenging. Other than the usual limiting factors such as lower abundance and ionization efficiency compared to analysis of non-glycosylated peptides, confident identification of sulfated glycopeptides among the more abundant non-sulfated glycopeptides requires additional considerations in the selective enrichment and detection strategies. Metal oxide has been applied to enrich phosphopeptides and sialylated glycopeptides, but its use to capture sulfated glycopeptides has not been investigated. Likewise, various complementary MS2 fragmentation modes have yet to be tested against sialylated and non-sialylated sulfoglycopeptides due to limited appropriate sample availability. In this study, we have investigated the feasibility of sequencing tryptic sulfated N-glycopeptide and its MS2 fragmentation characteristics by first optimizing the enrichment methods to allow efficient LC-MS detection and MS2 analysis by a combination of CID, HCD, ETD, and EThcD on hybrid and tribrid Orbitrap instruments. Characteristic sulfated glyco-oxonium ions and direct loss of sulfite from precursors were detected as evidences of sulfate modification. It is anticipated that the technical advances demonstrated in this study would allow a feasible extension of our sulfoglycomic analysis to sulfoglycoproteomics. [Figure not available: see fulltext.

  13. Separation and identification of selenotrisulfides in epithelial cell homogenates by LC-ICP-MS and LC-ESI-MS after incubation with selenite.

    PubMed

    Gabel-Jensen, Charlotte; Gammelgaard, Bente; Bendahl, Lars; Stürup, Stefan; Jøns, Ole

    2006-02-01

    To elucidate how selenite is metabolised in the intestine after oral intake, it was incubated with homogenized epithelial cells from pigs. When the metabolites were analysed by LC-ICP-MS, two major selenium metabolites were separated in the supernatant from the homogenate. These metabolites were formed instantly but disappeared within 15 min. No other selenium-containing compounds appeared during this time. Hence, the secondary reaction products were either volatilised or precipitated. To verify the identity of the compounds, a larger amount of selenite was incubated with epithelial cells. The presence of Cys-Se-SG and GS-Se-SG was verified by LC-ESI-MS. Selenotrisulfides were synthesized by reaction of L-cysteine and L-glutathione with sodium selenite. The reaction mixture contained three main products: selenodicysteine (Cys-Se-Cys), selenocysteine glutathione (Cys-Se-SG), and selenodiglutathione (GS-Se-SG). The two transient selenium compounds in the epithelial cell incubation mixture co-eluted with the synthesized Cys-Se-SG and GS-Se-SG, respectively. The identities of these compounds were verified by LC-ESI-MS. Hence, these selenium metabolites have now been identified by ESI-MS after isolation from epithelial cells.

  14. Simultaneous determination of eight chemicals in Fufang Xueshuantong capsules by LC-MS-MS with periodic polarity switching.

    PubMed

    Zhou, Chunhua; Su, Linfei; Shang, Weiding; Rong, Zhihuan; Sun, Mengmeng; Zhang, Kai; Shi, Xiaowei; Wang, Qiao

    2015-01-01

    A rapid, sensitive, selective and periodic polarity-switching liquid chromatography-tandem mass spectrometry(LC-MS-MS) method was developed for the simultaneous determination of eight components in an important traditional Chinese medicinal capsule, Fufang Xueshuantong. LC analysis was carried out on a Kinetex 2.6 µm XB-C18 column by gradient elution. The detection was performed by multiple reaction monitoring (MRM) with a periodic polarity-switching electrospray ionization (ESI) source across five periods of switching between positive and negative mode. Periodic polarity-switching was used to acquire maximal responses and to simultaneously detect eight constituents in one analysis run lasting 8 min. All of the analytes showed good linearity (r > 0.9947) in the tested ranges. The average recoveries were in the range of 95.4-103.9% with relative standard deviations ≤6.3%, and the intra- and inter-day variations were ≤3.7%. The developed method was successfully employed to analyze three batches of Fufang Xueshuantong capsule samples. The results showed that the levels of notoginsenoside R1, ginsenoside Rb1 and salvianolic acid B were clearly different in different batches of Fufang Xueshuantong capsules. Furthermore, the new established periodic polarity-switching LC-MS-MS method was proven to be highly sensitive and effective in evaluating the quality of Fufang Xueshuantong capsules. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Improved profiling of estrogen metabolites by orbitrap LC/MS

    PubMed Central

    Li, Xingnan; Franke, Adrian A.

    2015-01-01

    Estrogen metabolites are important biomarkers to evaluate cancer risks and metabolic diseases. Due to their low physiological levels, a sensitive and accurate method is required, especially for the quantitation of unconjugated forms of endogenous steroids and their metabolites in humans. Here, we evaluated various derivatives of estrogens for improved analysis by orbitrap LC/MS in human serum samples. A new chemical derivatization reagent was applied modifying phenolic steroids to form 1-methylimidazole-2-sulfonyl adducts. The method significantly improves the sensitivity 2–100 fold by full scan MS and targeted selected ion monitoring MS over other derivatization methods including, dansyl, picolinoyl, and pyridine-3-sulfonyl products. PMID:25543003

  16. Analysis of the differentially expressed low molecular weight peptides in human serum via an N-terminal isotope labeling technique combining nano-liquid chromatography/matrix-assisted laser desorption/ionization mass spectrometry.

    PubMed

    Leng, Jiapeng; Zhu, Dong; Wu, Duojiao; Zhu, Tongyu; Zhao, Ningwei; Guo, Yinlong

    2012-11-15

    Peptidomics analysis of human serum is challenging due to the low abundance of serum peptides and interference from the complex matrix. This study analyzed the differentially expressed (DE) low molecular weight peptides in human serum integrating a DMPITC-based N-terminal isotope labeling technique with nano-liquid chromatography and matrix-assisted laser desorption/ionization mass spectrometry (nano-LC/MALDI-MS). The workflow introduced a [d(6)]-4,6-dimethoxypyrimidine-2-isothiocyanate (DMPITC)-labeled mixture of aliquots from test samples as the internal standard. The spiked [d(0)]-DMPITC-labeled samples were separated by nano-LC then spotted on the MALDI target. Both quantitative and qualitative studies for serum peptides were achieved based on the isotope-labeled peaks. The DMPITC labeling technique combined with nano-LC/MALDI-MS not only minimized the errors in peptide quantitation, but also allowed convenient recognition of the labeled peptides due to the 6 Da mass difference. The data showed that the entire research procedure as well as the subsequent data analysis method were effective, reproducible, and sensitive for the analysis of DE serum peptides. This study successfully established a research model for DE serum peptides using DMPITC-based N-terminal isotope labeling and nano-LC/MALDI-MS. Application of the DMPITC-based N-terminal labeling technique is expected to provide a promising tool for the investigation of peptides in vivo, especially for the analysis of DE peptides under different biological conditions. Copyright © 2012 John Wiley & Sons, Ltd.

  17. High Throughput Analytical Techniques for the Determination and Confirmation of Residues of 653 Multiclass Pesticides and Chemical Pollutants in Tea by GC/MS, GC/MS/MS, and LC/MS/MS: Collaborative Study, First Action 2014.09.

    PubMed

    Pang, Guo-Fang; Fan, Chun-Lin; Cao, Yan-Zhong; Yan, Fang; Li, Yan; Kang, Jian; Chen, Hui; Chang, Qiao-Ying

    2015-01-01

    Thirty laboratories from fom North and South America, Europe, and Asia participated in this AOAC collaborative study (15 from China; five from Germany; two each from Italy and the United States; and one each from the Republic of Korea, Canada, Spain, Japan, Belgium, and India). Participants represented government regulatory, commercial testing, university, research institute, and private laboratories. The single-laboratory validated (SLV) tea method was evaluated in the collaborative study to determine the recovery and reproducibility of the method under multilaboratory conditions. Since there were no restrictions regarding the type of analytical instrumentation to use for the analyses, laboratories used a combination of equipment that included GC/MS, GC/MS/MS, and LC/MS/MS instruments from 22 different manufacturers, 21 brands of GC and LC columns, 13 different GC temperature programming profiles, 11 LC gradient elution programs, and six different vendor manufactured SPE cartridges. Even though all the analytical performance parameters for all the 653 compounds had been determined in the SLV study, guidance was obtained from an expert review panel of the AOAC Method-Centric Committee on Pesticide Residues to conduct the multilaboratory collaborative study based on 20 selected compounds that can be analyzed by GC/MS and 20 compounds that can be analyzed by LC/MS/MS. Altogether, 560 samples covering the 40 selected pesticides were analyzed in the study. These samples included green tea and oolong tea samples fortified typically at the European Union maximum residue limit for regulatory guidance and compliance, aged tea samples incurred with 20 pesticides, and green tea and oolong tea samples incurred with five pesticides. The analysis of the 560 samples generated a total of 82 459 test results by the 30 participating laboratories. One laboratory failed to meet the proficiency requirements in the precollaborative study. Therefore, its data submitted for the

  18. Screening of veterinary drug residues in food by LC-MS/MS. Background and challenges.

    PubMed

    Delatour, Thierry; Racault, Lucie; Bessaire, Thomas; Desmarchelier, Aurélien

    2018-04-01

    Regulatory agencies and government authorities have established maximum residue limits (MRL) in various food matrices of animal origin for supporting governments and food operators in the monitoring of veterinary drug residues in the food chain, and ultimately in the consumer's plate. Today, about 200 veterinary drug residues from several families, mainly with antibiotic, antiparasitic or antiinflammatory activities, are regulated in a variety of food matrices such as milk, meat or egg. This article provides a review of the regulatory framework in milk and muscle including data from Codex Alimentarius, Europe, the U.S.A., Canada and China for about 220 veterinary drugs. The article also provides a comprehensive overview of the challenge for food control, and emphasizes the pivotal role of liquid chromatography-mass spectrometry (LC-MS), either in tandem with quadrupoles (LC-MS/MS) or high resolution MS (LC-HRMS), for ensuring an adequate consumer protection combined with an affordable cost. The capability of a streamlined LC-MS/MS platform for screening 152 veterinary drug residues in a broad range of raw materials and finished products is highlighted in a production line perspective. The rationale for a suite of four methods intended to achieve appropriate performance in terms of scope and sensitivity is presented. Overall, the platform encompasses one stream for the determination of 105 compounds in a run (based on acidic QuEChERS-like), plus two streams for 23 β-lactams (alkaline QuEChERS-like) and 10 tetracyclines (low-temperature partitioning), respectively, and a dedicated stream for 14 aminoglycosides (molecularly-imprinted polymer).

  19. Monitoring of protease catalyzed reactions by quantitative MALDI MS using metal labeling.

    PubMed

    Gregorius, Barbara; Jakoby, Thomas; Schaumlöffel, Dirk; Tholey, Andreas

    2013-05-21

    Quantitative mass spectrometry is a powerful tool for the determination of enzyme activities as it does not require labeled substrates and simultaneously allows for the identification of reaction products. However, major restrictions are the limited number of samples which can be measured in parallel due to the need for isotope labeled internal standards. Here we describe the use of metal labeling of peptides for the setup of multiplexed enzyme activity assays. After proteolytic reaction, using the protease trypsin, remaining substrates and peptide products formed in the reaction were labeled with metal chelators complexing rare earth metal ions. Labeled peptides were quantified with high accuracy and over a wide dynamic range (at least 2 orders of magnitude) using MALDI MS in case of simple peptide mixtures or by LC-MALDI MS for complex substrate mixtures and used for the monitoring of time-dependent product formation and substrate consumption. Due to multiplexing capabilities and accuracy, the presented approach will be useful for the determination of enzyme activities with a wide range of biochemical and biotechnological applications.

  20. Development and validation of sensitive LC-MS/MS assays for quantification of HP-β-CD in human plasma and CSF.

    PubMed

    Jiang, Hui; Sidhu, Rohini; Fujiwara, Hideji; De Meulder, Marc; de Vries, Ronald; Gong, Yong; Kao, Mark; Porter, Forbes D; Yanjanin, Nicole M; Carillo-Carasco, Nuria; Xu, Xin; Ottinger, Elizabeth; Woolery, Myra; Ory, Daniel S; Jiang, Xuntian

    2014-07-01

    2-Hydroxypropyl-β-cyclodextrin (HP-β-CD), a widely used excipient for drug formulation, has emerged as an investigational new drug for the treatment of Niemann-Pick type C1 (NPC1) disease, a neurodegenerative cholesterol storage disorder. Development of a sensitive quantitative LC-MS/MS assay to monitor the pharmacokinetics (PKs) of HP-β-CD required for clinical trials has been challenging owing to the dispersity of the HP-β-CD. To support a phase 1 clinical trial for ICV delivery of HP-β-CD in NPC1 patients, novel methods for quantification of HP-β-CD in human plasma and cerebrospinal fluid (CSF) using LC-MS/MS were developed and validated: a 2D-LC-in-source fragmentation-MS/MS (2D-LC-IF-MS/MS) assay and a reversed phase ultra performance LC-MS/MS (RP-UPLC-MS/MS) assay. In both assays, protein precipitation and "dilute and shoot" procedures were used to process plasma and CSF, respectively. The assays were fully validated and in close agreement, and allowed determination of PK parameters for HP-β-CD. The LC-MS/MS methods are ∼100-fold more sensitive than the current HPLC assay, and were successfully employed to analyze HP-β-CD in human plasma and CSF samples to support the phase 1 clinical trial of HP-β-CD in NPC1 patients. Copyright © 2014 by the American Society for Biochemistry and Molecular Biology, Inc.

  1. New Method for the Analysis of Flukicide and Other Anthelmintic Residues in Bovine Milk and Liver using LC-MS/MS

    USDA-ARS?s Scientific Manuscript database

    A liquid chromatographic-tandem mass spectrometric (LC-MS/MS) multi-residue method for the simultaneous quantification and identification of 38 residues of the most widely used anthelmintic veterinary drugs (including benzimidazoles, macrocyclic lactones, and flukicides) in milk and liver has been d...

  2. Structure determination and sensory analysis of bitter-tasting 4-vinylcatechol oligomers and their identification in roasted coffee by means of LC-MS/MS.

    PubMed

    Frank, Oliver; Blumberg, Simone; Kunert, Christof; Zehentbauer, Gerhard; Hofmann, Thomas

    2007-03-07

    Aimed at elucidating intense bitter-tasting molecules in coffee, various bean ingredients were thermally treated in model experiments and evaluated for their potential to produce bitter compounds. As caffeic acid was found to generate intense bitterness reminiscent of the bitter taste of a strongly roasted espresso-type coffee, the reaction products formed were screened for bitter compounds by means of taste dilution analysis, and the most bitter tastants were isolated and purified. LC-MS/MS as well as 1-D/2-D NMR experiments enabled the identification of 10 bitter compounds with rather low recognition threshold concentrations ranging between 23 and 178 micromol/L. These bitter compounds are the previously unreported 1,3-bis(3',4'-dihydroxyphenyl) butane, trans-1,3-bis(3',4'-dihydroxyphenyl)-1-butene, and eight multiply hydroxylated phenylindanes, among which five derivatives are reported for the first time. In addition, the occurrence of each of these bitter compounds in a coffee brew was verified by means of LC-MS/MS (ESI-) operating in the multiple reaction monitoring (MRM) mode. The structures of these bitter compounds show strong evidence that they are generated by oligomerization of 4-vinylcatechol released from caffeic acid moieties upon roasting.

  3. Automated GC-MS analysis of free amino acids in biological fluids.

    PubMed

    Kaspar, Hannelore; Dettmer, Katja; Gronwald, Wolfram; Oefner, Peter J

    2008-07-15

    A gas chromatography-mass spectrometry (GC-MS) method was developed for the quantitative analysis of free amino acids as their propyl chloroformate derivatives in biological fluids. Derivatization with propyl chloroformate is carried out directly in the biological samples without prior protein precipitation or solid-phase extraction of the amino acids, thereby allowing automation of the entire procedure, including addition of reagents, extraction and injection into the GC-MS. The total analysis time was 30 min and 30 amino acids could be reliably quantified using 19 stable isotope-labeled amino acids as internal standards. Limits of detection (LOD) and lower limits of quantification (LLOQ) were in the range of 0.03-12 microM and 0.3-30 microM, respectively. The method was validated using a certified amino acid standard and reference plasma, and its applicability to different biological fluids was shown. Intra-day precision for the analysis of human urine, blood plasma, and cell culture medium was 2.0-8.8%, 0.9-8.3%, and 2.0-14.3%, respectively, while the inter-day precision for human urine was 1.5-14.1%.

  4. Metabolism of isorhynchophylline in rats detected by LC-MS.

    PubMed

    Wang, Wei; Ma, Chao-Mei; Hattori, Masao

    2010-01-01

    This paper investigates the metabolic fate of isorhynchophylline (ISOR) as a main bioactive oxindole alkaloid in the traditional Chinese medicine. After oral administration of ISOR to rats, plasma, bile, urine and feces were analyzed by LC-MS. Hydroxylation of ISOR and successive glucuronidation proceeded in vitro by incubation with rat liver microsomes. ISOR was identified in plasma, 11-hydroxyisorhynchophylline 11-O--D-glucuronide (MI1) and 10-hydroxyisorhynchophylline 10-O--D-glucuronide (MI2) in bile, and free 11-hydroxyisorhynchophylline (MI3) and 10-hydroxyisorhynchophylline (MI4) in urine and feces. Within 24 h, 71.6% of ISOR was excreted into the feces (in 20.0 g) and 13.8% into the urine (in 20.0 ml) of rats after oral administration of 37.5 mg/kg. Monitoring by LC-MS showed that 8.5% of ISOR was metabolized to MI3 and MI4 in a ratio of ca. 1:1. Specific inhibition of CYP isozymes indicated that CYP2D, CYP1A1/2 and CYP2C participate in ISOR hydroxylation. ISOR was involved in the circulatory system after oral administration. Cytochrome P450 (CYP) in rat liver microsomes played a key role in ISOR hydroxylation.

  5. LC-DAD-MS (ESI+) analysis and antioxidant capacity of crocus sativus petal extracts.

    PubMed

    Termentzi, Aikaterini; Kokkalou, Eugene

    2008-04-01

    In this study, various fractions isolated from the petals of Crocus sativus were assessed at first for their phenolic content both qualitatively and quantitatively and secondly for their antioxidant activity. The phytochemical analysis was carried out by LC-DAD-MS (ESI (+)) whereas the antioxidant potential was evaluated by applying two methodologies, the DPPH. radical scavenging activity test and the Co(II)-induced luminol chemiluminescence procedure. According to data obtained from these antioxidant tests, the diethyl ether, ethyl acetate and aqueous fractions demonstrated the strongest antioxidant capacity. Interestingly, the major constituents identified in these fractions correspond to kaempferol, quercetin, naringenin and some flavanone and flavanol derivatives glycosylated and esterified with phenylpropanoic acids. In addition, the presence of some nitrogen-containing substances, as well as other phenolics and phenylpropanoic derivatives was also traced. The identification and structural elucidation of all substances isolated in this study was achieved by both comparing available literature data and by proposed fragmentation mechanisms based on evaluating the LC-DAD-MS (ESI (+)) experimental data. The quantitative analysis data obtained thus far have shown that Crocus sativus petals are a rich source of flavonoids. Such a fact suggests that the good antioxidant capacity detected in the various fractions of Crocus sativus petals could be attributed to the presence of flavonoids, since it is already known that these molecules exert antioxidant capability. The latter, along with the use of Crocus sativus in food and pharmaceutical industry is discussed.

  6. Dependence of matrix effect on ionization polarity during LC-ESI-MS analysis of derivatized amino acids in some natural samples.

    PubMed

    Oldekop, Maarja-Liisa; Rebane, Riin; Herodes, Koit

    2017-10-01

    Matrix effect, the influence of co-eluting components on the ionization efficiency of the analyte, affects the trueness and precision of the LC-ESI-MS analysis. Derivatization can reduce or eliminate matrix effect, for example, diethyl ethoxymethylenemalonate (DEEMM) derivatives have shown less matrix effect compared to other derivatives. Moreover, the use of negative ion mode can further reduce matrix effect. In order to investigate the combination of derivatization and different ionization modes, an LC-ESI-MS/MS method using alternating positive/negative ion mode was developed and validated. The analyses in positive and negative ion modes had comparable limit of quantitation values. The influence of ESI polarity on matrix effect was investigated during the analysis of 22 DEEMM-derivatized amino acids in herbal extracts and honeys. Sample dilution approach was used for the evaluation of the presence of matrix effect. Altogether, 4 honeys and 11 herbal extracts were analyzed, and the concentrations of 22 amino acids in the samples are presented. In the positive ion mode, matrix effect was observed for several amino acid derivatives and the matrix effect was stronger in honey samples compared to the herbal extracts. The negative ion mode was free from matrix effect, with only few exceptions in honeys (average relative standard deviation over all analytes and matrices was 8%; SD = 7%). The matrix effect was eliminated in the positive ion mode by sample dilution and agreement between concentrations from the two ion modes was achieved for most amino acids. In conclusion, it was shown that the combination of derivatization and negative ion mode can be a powerful tool for minimizing matrix effect in more complicated applications.

  7. Identification and Characterization of Reaction Products of 5-Hydroxytryptamine with Methylglyoxal and Glyoxal by LC/MS/MS.

    PubMed

    Sai Sachin, L; Nagarjuna Chary, R; Pavankumar, P; Prabhakar, S

    2018-06-06

    The methylglyoxal (MGO) and glyoxal (GO) are known to be at high levels in the diabetic humans. They react with amine containing proteins and amino acids to form advanced glycation end products, however, the reactivity with the other amine containing metabolites, such as neurotransmitters are not explored. In this study, we aimed at studying the reactivity of 5-hydroxytryptamine (5-HT) with MGO or GO, which may alter the metabolic function of 5-HT. The stock solutions of 5-HT, MGO and GO were made in PBS buffer at pH 7.4 and incubated 5-HT with MGO or GO at difference concentrations. The reactions were also performed at physiological concentrations. The reaction mixtures collected at different incubation times were analyzed by direct ESI-HRMS, LC/MS and LC/MS/MS conditions to detect/characterize the products. Agilent 6545 Q-TOF and Agilent 6420 triple quadrupole mass spectrometer were used for the study, and LC separations were performed on a C18 column. The direct ESI-HRMS data of the reaction mixtures showed formation of three and four reaction products when 5-HT reacted with MGO and GO, respectively. All the products showed dominant [M+H] + ions. The products were characterized by HRMS, LC/MS/MS and the literature reports on similar compounds. The products can easily be identified by LC/MS based on the accurate mass values together with retention time information. The MS/MS of the reaction products showed structure indicative fragment ions. 5-HT reacts with one or two MGO/GO to form a set of reaction products. The reaction between 5-HT and MGO or GO was faster at higher concentrations of MGO/GO (<10 min), and the same products were found even at physiological concentrations (<48 hrs). The LC-MS/MS (SRM) method can be used to screen the reaction products when present at low level. This article is protected by copyright. All rights reserved.

  8. Comprehensive Optimization of LC-MS Metabolomics Methods Using Design of Experiments (COLMeD).

    PubMed

    Rhoades, Seth D; Weljie, Aalim M

    2016-12-01

    Both reverse-phase and HILIC chemistries are deployed for liquid-chromatography mass spectrometry (LC-MS) metabolomics analyses, however HILIC methods lag behind reverse-phase methods in reproducibility and versatility. Comprehensive metabolomics analysis is additionally complicated by the physiochemical diversity of metabolites and array of tunable analytical parameters. Our aim was to rationally and efficiently design complementary HILIC-based polar metabolomics methods on multiple instruments using Design of Experiments (DoE). We iteratively tuned LC and MS conditions on ion-switching triple quadrupole (QqQ) and quadrupole-time-of-flight (qTOF) mass spectrometers through multiple rounds of a workflow we term COLMeD (Comprehensive optimization of LC-MS metabolomics methods using design of experiments). Multivariate statistical analysis guided our decision process in the method optimizations. LC-MS/MS tuning for the QqQ method on serum metabolites yielded a median response increase of 161.5% (p<0.0001) over initial conditions with a 13.3% increase in metabolite coverage. The COLMeD output was benchmarked against two widely used polar metabolomics methods, demonstrating total ion current increases of 105.8% and 57.3%, with median metabolite response increases of 106.1% and 10.3% (p<0.0001 and p<0.05 respectively). For our optimized qTOF method, 22 solvent systems were compared on a standard mix of physiochemically diverse metabolites, followed by COLMeD optimization, yielding a median 29.8% response increase (p<0.0001) over initial conditions. The COLMeD process elucidated response tradeoffs, facilitating improved chromatography and MS response without compromising separation of isobars. COLMeD is efficient, requiring no more than 20 injections in a given DoE round, and flexible, capable of class-specific optimization as demonstrated through acylcarnitine optimization within the QqQ method.

  9. Comprehensive Optimization of LC-MS Metabolomics Methods Using Design of Experiments (COLMeD)

    PubMed Central

    Rhoades, Seth D.

    2017-01-01

    Introduction Both reverse-phase and HILIC chemistries are deployed for liquid-chromatography mass spectrometry (LC-MS) metabolomics analyses, however HILIC methods lag behind reverse-phase methods in reproducibility and versatility. Comprehensive metabolomics analysis is additionally complicated by the physiochemical diversity of metabolites and array of tunable analytical parameters. Objective Our aim was to rationally and efficiently design complementary HILIC-based polar metabolomics methods on multiple instruments using Design of Experiments (DoE). Methods We iteratively tuned LC and MS conditions on ion-switching triple quadrupole (QqQ) and quadrupole-time-of-flight (qTOF) mass spectrometers through multiple rounds of a workflow we term COLMeD (Comprehensive optimization of LC-MS metabolomics methods using design of experiments). Multivariate statistical analysis guided our decision process in the method optimizations. Results LC-MS/MS tuning for the QqQ method on serum metabolites yielded a median response increase of 161.5% (p<0.0001) over initial conditions with a 13.3% increase in metabolite coverage. The COLMeD output was benchmarked against two widely used polar metabolomics methods, demonstrating total ion current increases of 105.8% and 57.3%, with median metabolite response increases of 106.1% and 10.3% (p<0.0001 and p<0.05 respectively). For our optimized qTOF method, 22 solvent systems were compared on a standard mix of physiochemically diverse metabolites, followed by COLMeD optimization, yielding a median 29.8% response increase (p<0.0001) over initial conditions. Conclusions The COLMeD process elucidated response tradeoffs, facilitating improved chromatography and MS response without compromising separation of isobars. COLMeD is efficient, requiring no more than 20 injections in a given DoE round, and flexible, capable of class-specific optimization as demonstrated through acylcarnitine optimization within the QqQ method. PMID:28348510

  10. Simultaneous extraction of propofol and propofol glucuronide from hair followed by validated LC-MS/MS analyses.

    PubMed

    Maas, Alexandra; Maier, Christoph; Iwersen-Bergmann, Stefanie; Madea, Burkhard; Hess, Cornelius

    2017-11-30

    Besides its clinical application, the anaesthetic agent propofol is being increasingly misused, mostly by healthcare professionals, and its abuse potential gained worldwide attention after the tragic death of Michael Jackson in 2009. Due to the short duration of its narcotic effects, propofol abuse is especially easy to hide compared with the use of other recreational drugs. However, propofol possesses a very narrow therapeutic window between the desired effect and potentially fatal toxicity, making abuse of the drug extremely dangerous even in experienced physicians. Consequently, it is important that forensic laboratories possess a sensitive and specific method for the detection of chronic propofol abuse. We present a simple, fast and reliable method to simultaneously extract propofol and its main metabolite propofol glucuronide from hair, followed by sensitive LC-MS/MS analyses, allowing to determine a chronic propofol abuse. Difficulties regarding the detection of propofol using LC-MS/MS were solved by using a derivatization reaction with 2-fluoro-1-methylpyridinium-p-toluene-sulfonate and triethylamine. Reliability of extraction method and subsequent LC-MS/MS analyses was confirmed under consideration of the validation parameters selectivity, linearity, accuracy and precision, analytical limits, processed sample stability, matrix effects and recovery. Appropriate quantification (LLOQ=10pg/mg hair) and detection limits (3.6pg/mg hair for propofol and 7.8 pg/mg hair for propofol glucuronide) could be achieved, enabling to detect even small amounts of both analytes. Applicability of the method was confirmed by analysis of three human hair samples from deceased with suspicion of chronic propofol abuse. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Comparison of enzyme kinetics of warfarin analyzed by LC-MS/MS QTrap and differential mobility spectrometry.

    PubMed

    Shaik, Abdul Naveed; Grater, Richard; Lulla, Mukesh; Williams, David A; Gan, Lawrence L; Bohnert, Tonika; LeDuc, Barbara W

    2016-01-01

    Warfarin is an anticoagulant used in the treatment of thrombosis and thromboembolism. It is given as a racemic mixture of R and S enantiomers. These two enantiomers show differences in metabolism by CYPs: S-warfarin undergoes 7 hydroxylation by CYP2C9 and R-warfarin by CYP3A4 to form 10 hydroxy warfarin. In addition, warfarin is acted upon by different CYPs to form the minor metabolites 3'-hydroxy, 4'-hydroxy, 6-hydroxy, and 8-hydroxy warfarin. For analysis, separation of these metabolites is necessary since all have the same m/z ratio and similar fragmentation pattern. Enzyme kinetics for the formation of all of the six hydroxylated metabolites of warfarin from human liver microsomes were determined using an LC-MS/MS QTrap and LC-MS/MS with a differential mobility spectrometry (DMS) (SelexION™) interface to compare the kinetic parameters. These two methods were chosen to compare their selectivity and sensitivity. Substrate curves for 3'-OH, 4'-OH, 6-OH, 7-OH, 8-OH and 10-OH warfarin formation were generated to determine the kinetic parameters (Km and Vmax) in human liver microsomal preparations. The limit of quantitation (LOQ) for all the six hydroxylated metabolites of warfarin were in the range of 1-3nM using an LC-MS/MS QTrap method which had a run time of 22min. In contrast, the LOQ for all the six hydroxylated metabolites using DMS interface technology was 100nM with a run time of 2.8min. We compare these two MS methods and discuss the kinetics of metabolite formation for the metabolites generated from racemic warfarin. In addition, we show inhibition of major metabolic pathways of warfarin by sulfaphenazole and ketoconazole which are known specific inhibitors of CYP2C9 and CYP3A4 respectively. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Relative quantification of biomarkers using mixed-isotope labeling coupled with MS

    PubMed Central

    Chapman, Heidi M; Schutt, Katherine L; Dieter, Emily M; Lamos, Shane M

    2013-01-01

    The identification and quantification of important biomarkers is a critical first step in the elucidation of biological systems. Biomarkers take many forms as cellular responses to stimuli and can be manifested during transcription, translation, and/or metabolic processing. Increasingly, researchers have relied upon mixed-isotope labeling (MIL) coupled with MS to perform relative quantification of biomarkers between two or more biological samples. MIL effectively tags biomarkers of interest for ease of identification and quantification within the mass spectrometer by using isotopic labels that introduce a heavy and light form of the tag. In addition to MIL coupled with MS, a number of other approaches have been used to quantify biomarkers including protein gel staining, enzymatic labeling, metabolic labeling, and several label-free approaches that generate quantitative data from the MS signal response. This review focuses on MIL techniques coupled with MS for the quantification of protein and small-molecule biomarkers. PMID:23157360

  13. Identification of Acetaminophen Adducts of Rat Liver Microsomal Proteins using 2D-LC-MS/MS.

    PubMed

    Golizeh, Makan; LeBlanc, André; Sleno, Lekha

    2015-11-16

    Xenobiotic metabolism in the liver can give rise to reactive metabolites that covalently bind to proteins, and determining which proteins are targeted is important in drug discovery and molecular toxicology. However, there are difficulties in the analysis of these modified proteins in complex biological matrices due to their low abundance. In this study, an analytical approach was developed to systematically identify target proteins of acetaminophen (APAP) in rat liver microsomes (RLM) using two-dimensional chromatography and high-resolution tandem mass spectrometry. In vitro microsomal incubations, with and without APAP, were digested and subjected to strong cation exchange (SCX) fractionation prior to reverse-phase UHPLC-MS/MS. Four data processing strategies were combined into an efficient label-free workflow meant to eliminate potential false positives, using peptide spectral matching, statistical differential analysis, product ion screening, and a custom-built delta-mass filtering tool to pinpoint potential modified peptides. This study revealed four proteins, involved in important cellular processes, to be covalently modified by APAP. Data are available via ProteomeXchange with identifier PXD002590.

  14. Enhancing analysis throughput, sensitivity and specificity in LC/ESI-MS/MS assay of plasma 25-hydroxyvitamin D3 by derivatization with triplex 4-(4-dimethylaminophenyl)-1,2,4-triazoline-3,5-dione (DAPTAD) isotopologues.

    PubMed

    Ogawa, Shoujiro; Kittaka, Hiroki; Nakata, Akiho; Komatsu, Kenji; Sugiura, Takahiro; Satoh, Mamoru; Nomura, Fumio; Higashi, Tatsuya

    2017-03-20

    The plasma/serum concentration of 25-hydroxyvitamin D 3 [25(OH)D 3 ] is a diagnostic index for vitamin D deficiency/insufficiency, which is associated with a wide range of diseases, such as rickets, cancer and diabetes. We have reported that the derivatization with 4-(4-dimethylaminophenyl)-1,2,4-triazoline-3,5-dione (DAPTAD) works well in the liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) assay of the serum/plasma 25(OH)D 3 for enhancing the sensitivity and the separation from a potent interfering metabolite, 3-epi-25-hydroxyvitamin D 3 [3-epi-25(OH)D 3 ]. However, enhancing the analysis throughput remains an issue in the LC/ESI-MS/MS assay of 25(OH)D 3 . The most obvious restriction of the LC/MS/MS throughput is the chromatographic run time. In this study, we developed an enhanced throughput method for the determination of the plasma 25(OH)D 3 by LC/ESI-MS/MS combined with the derivatization using the triplex ( 2 H 0 -, 2 H 3 - and 2 H 6 -) DAPTAD isotopologues. After separate derivatization with 1 of 3 different isotopologues, the 3 samples were combined and injected together into LC/ESI-MS/MS. Based on the mass differences between the isotopologues, the derivatized 25(OH)D 3 in the 3 different samples were quantified within a single run. The developed method tripled the hourly analysis throughput without sacrificing assay performance, i.e., ease of pretreatment of plasma sample (only deproteinization), limit of quantification (1.0ng/mL when a 5μL-plasma was used), precision (intra-assay RSD≤5.9% and inter-assay RSD≤5.5%), accuracy (98.7-102.2%), matrix effects, and capability of separating from an interfering metabolite, 3-epi-25(OH)D 3 . The multiplexing of samples by the isotopologue derivatization was applied to the analysis of plasma samples of healthy subjects and the developed method was proven to have a satisfactory applicability. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. eMZed: an open source framework in Python for rapid and interactive development of LC/MS data analysis workflows.

    PubMed

    Kiefer, Patrick; Schmitt, Uwe; Vorholt, Julia A

    2013-04-01

    The Python-based, open-source eMZed framework was developed for mass spectrometry (MS) users to create tailored workflows for liquid chromatography (LC)/MS data analysis. The goal was to establish a unique framework with comprehensive basic functionalities that are easy to apply and allow for the extension and modification of the framework in a straightforward manner. eMZed supports the iterative development and prototyping of individual evaluation strategies by providing a computing environment and tools for inspecting and modifying underlying LC/MS data. The framework specifically addresses non-expert programmers, as it requires only basic knowledge of Python and relies largely on existing successful open-source software, e.g. OpenMS. The framework eMZed and its documentation are freely available at http://emzed.biol.ethz.ch/. eMZed is published under the GPL 3.0 license, and an online discussion group is available at https://groups.google.com/group/emzed-users. Supplementary data are available at Bioinformatics online.

  16. Comprehensive analysis of the lipophilic reactive carbonyls present in biological specimens by LC/ESI-MS/MS.

    PubMed

    Tomono, Susumu; Miyoshi, Noriyuki; Ohshima, Hiroshi

    2015-04-15

    A new analytical method has been developed for profiling lipophilic reactive carbonyls (RCs) such as aldehydes and ketones in biological samples using liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) with selected reaction monitoring (SRM). The method consists of several phases, including (1) extraction of lipophilic RCs with a chloroform/methanol mixture; (2) derivatization of the extracted RCs with dansyl hydrazine (DH); and (3) SRM detection of the characteristic product ion of the 5-dimethylaminonaphthalene-1-sulfonyl moiety (m/z 236.1). The analytical results were expressed as RC maps, which allowed for the occurrence and levels of different lipophilic RCs to be visualized. We also developed a highly reproducible and accurate method to extract, purify and derivatize RCs in small volumes of biological specimens. This method was applied to the detection of free RCs in mice plasma samples, and resulted in the detection of more than 400 RCs in samples obtained from C57BL/6J mice. Thirty-four of these RCs were identified by comparison with authentic RCs. This method could be used to investigate the levels of RCs in biological and environmental samples, as well as studying the role of lipid peroxidation in oxidative stress related-disorders and discovering new biomarkers for the early diagnosis of these diseases. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. The clinical impact of recent advances in LC-MS for cancer biomarker discovery and verification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Hui; Shi, Tujin; Qian, Wei-Jun

    2015-12-04

    Mass spectrometry-based proteomics has become an indispensable tool in biomedical research with broad applications ranging from fundamental biology, systems biology, and biomarker discovery. Recent advances in LC-MS have made it become a major technology in clinical applications, especially in cancer biomarker discovery and verification. To overcome the challenges associated with the analysis of clinical samples, such as extremely wide dynamic range of protein concentrations in biofluids and the need to perform high throughput and accurate quantification, significant efforts have been devoted to improve the overall performance of LC-MS bases clinical proteomics. In this review, we summarize the recent advances inmore » LC-MS in the aspect of cancer biomarker discovery and quantification, and discuss its potentials, limitations, and future perspectives.« less

  18. Determination of the glycation sites of Bacillus anthracis neoglycoconjugate vaccine by MALDI-TOF/TOF-CID-MS/MS and LC-ESI-QqTOF-tandem mass spectrometry

    PubMed Central

    Jahouh, Farid; Hou, Shu-jie; Kováč, Pavol; Banoub, Joseph H.

    2012-01-01

    We present herein an efficient mass spectrometric method for the localization of the glycation sites of a model neoglycoconjugate vaccine formed by a construct of the tetrasaccharide side chain of the Bacillus anthracis exosporium and the protein carrier bovine serum albumin. The glycoconjugate was digested with both trypsin and GluC V8 endoproteinases, and the digests were then analyzed by MALDI-TOF/TOF-CID-MS/MS and nano-LC-ESI-QqTOF-CID-MS/MS. The sequences of the unknown peptides analyzed by MALDI-TOF/TOF-CID-MS/MS, following digestion with the GluC V8 endoproteinase, allowed us to recognize three glycopeptides whose glycation occupancies were, respectively, on Lys 235, Lys 420, and Lys 498. Similarly, the same analysis was performed on the tryptic digests, which permitted us to recognize two glycation sites on Lys 100 and Lys 374. In addition, we have also used LC-ESI-QqTOF-CID-MS/MS analysis for the identification of the tryptic digests. However, this analysis identified a higher number of glycopeptides than would be expected from a glycoconjugate composed of a carbohydrate–protein ratio of 5.4:1, which would have resulted in glycation occupancies of 18 specific sites. This discrepancy was due to the large number of glycoforms formed during the synthetic carbohydrate–spacer–carrier protein conjugation. Likewise, the LC-ESI-QqTOF-MS/MS analysis of the GluC V8 digest also identified 17 different glycation sites on the synthetic glycoconjugate. PMID:22012665

  19. Liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) based bioavailability determination of the major classes of phytochemicals.

    PubMed

    Stylos, Evgenios; Chatziathanasiadou, Maria V; Syriopoulou, Aggeliki; Tzakos, Andreas G

    2017-03-15

    Natural products derived from plants have served as an inexhausted source for drug discovery and drug development. They have been evolutionary amplified with drug-like properties and have already illustrated immense therapeutic potential over an array of different diseases. However, their incorporation in the drug discovery pipeline has been diminished the last two decades. This was probably due to barriers related to their inherent difficulties to be integrated in high-throughput screening assays as also their largely unexplored bioavailability. Analytical procedures have come into the spotlight, a result of the continuous development of the instrumentation's capabilities as far as detection and separation is concerned. Integral part of this technological evolution is LC-MS instrumentation and its extended use for the determination of various compounds. The fact that it provides extra sensitivity, specificity and good separation in complex samples, makes LC-MS/MS the ultimate tool in the determination of many types of chemical compounds, such as phytochemicals. Herein, we focus on the achievements of the last five years in quantitative analysis of the major classes of phytochemicals (flavonoids, alkaloids, terpenes, glycosides and saponins) in plasma, through LC-MS/MS, as also their bioavailability. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Highly sensitive quantification of serum malonate, a possible marker for de novo lipogenesis, by LC-ESI-MS/MS

    PubMed Central

    Honda, Akira; Yamashita, Kouwa; Ikegami, Tadashi; Hara, Takashi; Miyazaki, Teruo; Hirayama, Takeshi; Numazawa, Mitsuteru; Matsuzaki, Yasushi

    2009-01-01

    We describe a new sensitive and specific method for the quantification of serum malonate (malonic acid, MA), which could be a new biomarker for de novo lipogenesis (fatty acid synthesis). This method is based upon a stable isotope-dilution technique using LC-MS/MS. MA from 50 μl of serum was derivatized into di-(1-methyl-3-piperidinyl)malonate (DMP-MA) and quantified by LC-MS/MS using the positive electrospray ionization mode. The detection limit of the DMP-MA was approximately 4.8 fmol (500 fg) (signal-to-noise ratio = 10), which was more than 100 times more sensitive compared with that of MA by LC-MS/MS using the negative electrospray ionization mode. The relative standard deviations between sample preparations and measurements made using the present method were 4.4% and 3.2%, respectively, by one-way ANOVA. Recovery experiments were performed using 50 μl aliquots of normal human serum spiked with 9.6 pmol (1 ng) to 28.8 pmol (3 ng) of MA and were validated by orthogonal regression analysis. The results showed that the estimated amount within a 95% confidence limit was 14.1 ± 1.1 pmol, which was in complete agreement with the observed X¯0 = 15.0 ± 0.6 pmol, with a mean recovery of 96.0%. This method provides reliable and reproducible results for the quantification of MA in human serum. PMID:19403942

  1. How much separation for LC-MS/MS quantitative bioanalysis of drugs and metabolites?

    PubMed

    Tan, Aimin; Fanaras, John C

    2018-05-01

    LC-MS/MS has been the dominant analytical technology for quantitative bioanalysis of drugs and metabolites for more than two decades. Despite this, a very fundamental question like how much separation is required for LC-MS/MS quantitative bioanalysis of drugs and metabolites has not been adequately addressed. Some think that no or only very limited separation is necessary thanks to the unparalleled selectivity offered by tandem mass spectrometry. Others think that the more separation, the better, because of the potential detrimental impact of matrix effect (ion suppression or enhancement). Still others just use a rule-of-thumb approach by keeping the adjusted retention/capacity factor always between 2 and 5. The purpose of this article is to address this fundamental question through rational thinking together with various real case examples drawn from regulated bioanalytical laboratories. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. The application of multiple analyte adduct formation in the LC-MS3 analysis of valproic acid in human serum.

    PubMed

    Dziadosz, Marek

    2017-01-01

    LC-MS using electrospray ionisation (negative ion mode) and low-energy collision-induced dissociation tandem mass spectrometric (CID-MS/MS) analysis, together with the multiple analyte adduct formation with the components of the mobile phase, were applied to analyse valproic acid in human serum with LC-MS 3 . The CID-fragmentation of the precursor analyte adduct [M+2CH 3 COONa-H] - was applied in the method validation (307.1/225.1/143.0). Chromatographic separation was performed with a Luna 5μm C18 (2) 100A, 150mm×2mm column and the elution with a mobile phase consisting of A (H 2 O/methanol=95/5, v/v) and B (H 2 O/methanol=3/97, v/v), both with 10mM ammonium acetate and 0.1% acetic acid. A binary flow pumping mode with a total flow rate of 0.400mL/min was used. The calculated limit of detection/quantification of the method calibrated in the range of 10-200μg/mL was 0.31/1.0μg/mL. The sample preparation based on protein precipitation with 1mL of H 2 O/methanol solution (3/97, v/v) with 10mM sodium acetate and 100mM acetic acid. On the basis of the experiments performed could be demonstrated, that multiple analyte adduct formation can be applied to generate MS 3 quantitation of analytes with problematic fragmentation. The presented new strategy makes the analysis of small drugs, which do not produce any stable product ions at all, on the basis of LC-MS 3 possible. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. High-Throughput Quantitation of Neonicotinoids in Lyophilized Surface Water by LC-APCI-MS/MS.

    PubMed

    Morrison, Lucas M; Renaud, Justin B; Sabourin, Lyne; Sumarah, Mark W; Yeung, Ken K C; Lapen, David R

    2018-05-21

    Background : Neonicotinoids are among the most widely used insecticides. Recently, there has been concern associated with unintended adverse effects on honeybees and aquatic invertebrates at low parts-per-trillion levels. Objective : There is a need for LC-MS/MS methods that are capable of high-throughput measurements of the most widely used neonicotinoids at environmentally relevant concentrations in surface water. Methods : This method allows for quantitation of acetamiprid, clothianidin, imidacloprid, dinotefuran, nitenpyram, thiacloprid, and thiamethoxam in surface water. Deuterated internal standards are added to 20 mL environmental samples, which are concentrated by lyophilisation and reconstituted with methanol followed by acetonitrile. Results : A large variation of mean recovery efficiencies across five different surface water sampling sites within this study was observed, ranging from 45 to 74%. This demonstrated the need for labelled internal standards to compensate for these differences. Atmospheric pressure chemical ionization (APCI) performed better than electrospray ionization (ESI) with limited matrix suppression, achieving 71-110% of the laboratory fortified blank signal. Neonicotinoids were resolved on a C18 column using a 5 min LC method, in which MQL ranged between 0.93 and 4.88 ng/L. Conclusions : This method enables cost effective, accurate, and reproducible monitoring of these pesticides in the aquatic environment. Highlights : Lyophilization is used for high throughput concentration of neonicotinoids in surface water. Variations in matrix effects between samples was greatly reduced by using APCI compared with ESI. Clothianidin and thiamethoxam were detected in all samples with levels ranging from below method quantitation limit to 65 ng/L.

  4. Development of a SIDA-LC-MS/MS Method for the Determination of Phomopsin A in Legumes.

    PubMed

    Schloß, Svenja; Koch, Matthias; Rohn, Sascha; Maul, Ronald

    2015-12-09

    A novel method for the determination of phomopsin A (1) in lupin flour, pea flour, and bean flour as well as whole lupin plants was established based on stable isotope dilution assay (SIDA) LC-MS/MS using (15)N6-1 as an isotopically labeled internal standard. Artificially infected samples were used to develop an optimized extraction procedure and sample pretreatment. The limits of detection were 0.5-1 μg/kg for all matrices. The limits of quantitation were 2-4 μg/kg. The method was used to analyze flour samples generated from selected legume seeds and lupin plant samples that had been inoculated with Diaporthe toxica and two further fungal strains. Finally, growing lupin plants infected with D. toxica were investigated to simulate a naturally in-field mycotoxicosis. Toxin levels of up to 10.1 μg/kg of 1 were found in the pods and 7.2 μg/kg in the stems and leaves.

  5. Dual quantification of dapivirine and maraviroc in cervicovaginal secretions from ophthalmic tear strips and polyester-based swabs via liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis.

    PubMed

    Parsons, Teresa L; Emory, Joshua F; Seserko, Lauren A; Aung, Wutyi S; Marzinke, Mark A

    2014-09-01

    Topical microbicidal agents are being actively pursued as a modality to prevent HIV viral transmission during sexual intercourse. Quantification of antiretroviral agents in specimen sources where antiviral activity is elicited is critical, and drug measurements in cervicovaginal fluid can provide key information on local drug concentrations. Two antiretroviral drugs, dapivirine and maraviroc, have gained interest as vaginal microbicidal agents, and rugged methods are required for their quantification in cervicovaginal secretions. Cervicovaginal fluid spiked with dapivirine and maraviroc were applied to ophthalmic tear strips or polyester-based swabs to mimic collection procedures used in clinical studies. Following sample extraction and the addition of isotopically labeled internal standards, samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis using a Waters BEH C8, 50mm×2.1mm, 1.7μm particle size column, on an API 4000 mass analyzer operated in selective reaction monitoring mode. The method was validated according to FDA Bioanalytical Method Validation guidelines. Due to the disparate saturation capacity of the tested collection devices, the analytical measuring ranges for dapivirine and maravirocin cervicovaginal fluid on the ophthalmic tear strip were 0.05-25ng/tear strip, and 0.025-25ng/tear strip, respectively. As for the polyester-based swab, the analytical measuring ranges were 0.25-125ng/swab for dapivirine and 0.125-125ng/swab for maraviroc. Dilutional studies were performed for both analytes to extended ranges of 25,000ng/tear strip and 11,250ng/swab. Standard curves were generated via weighted (1/x(2)) linear or quadratic regression of calibrators. Precision, accuracy, stability and matrix effects studies were all performed and deemed acceptable according to the recommendations of the FDA Bioanalytical Method Validation guidelines. A rugged LC-MS/MS method for the dual quantification of dapivirine and

  6. Dual Quantification of Dapivirine and Maraviroc in Cervicovaginal Secretions from Ophthalmic Tear Strips and Polyester-Based Swabs via Liquid Chromatographic-Tandem Mass Spectrometric (LC-MS/MS) Analysis

    PubMed Central

    Parsons, Teresa L.; Emory, Joshua F.; Seserko, Lauren A.; Aung, Wutyi S.; Marzinke, Mark A.

    2014-01-01

    Background Topical microbicidal agents are being actively pursued as a modality to prevent HIV viral transmission during sexual intercourse. Quantification of antiretroviral agents in specimen sources where antiviral activity is elicited is critical, and drug measurements in cervicovaginal fluid can provide key information on local drug concentrations. Two antiretroviral drugs, dapivirine and maraviroc, have gained interest as vaginal microbicidal agents, and rugged methods are required for their quantification in cervicovaginal secretions. Methods Cervicovaginal fluid spiked with dapivirine and maraviroc were applied to ophthalmic tear strips or polyester-based swabs to mimic collection procedures used in clinical studies. Following sample extraction and the addition of isotopically-labeled internal standards, samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis using a Waters BEH C8, 50 × 2.1 mm, 1.7 µm particle size column, on an API 4000 mass analyzer operated in selective reaction monitoring mode. The method was validated according to FDA Bioanalytical Method Validation guidelines. Results Due to the disparate saturation capacity of the tested collection devices, the analytical measuring ranges for dapivirine and maravirocin cervicovaginal fluid on the ophthalmic tear strip were 0.05 to 25 ng/tear strip, and 0.025 to 25 ng/tear strip, respectively. As for the polyester-based swab, the analytical measuring ranges were 0.25 to 125 ng/swab for dapivirine and 0.125 to 125 ng/swab for maraviroc. Dilutional studies were performed for both analytes to extended ranges of 25,000 ng/tear strip and 11,250 ng/swab. Standard curves were generated via weighted (1/x2) linear or quadratic regression of calibrators. Precision, accuracy, stability and matrix effects studies were all performed and deemed acceptable according to the recommendations of the FDA Bioanalytical Method Validation guidelines. Conclusions A rugged LC-MS/MS

  7. Novel LC/MS/MS and High-Throughput Mass Spectrometric Assays for Monoacylglycerol Acyltransferase Inhibitors.

    PubMed

    Qi, Jenson; Masucci, John A; Lang, Wensheng; Connelly, Margery A; Caldwell, Gary W; Petrounia, Ioanna; Kirkpatrick, Jennifer; Barnakov, Alexander N; Struble, Geoffrey; Miller, Robyn; Dzordzorine, Keli; Kuo, Gee-Hong; Gaul, Michael; Pocai, Alessandro; Lee, Seunghun

    2017-04-01

    Monoacylglycerol acyltransferase enzymes (MGAT1, MGAT2, and MGAT3) convert monoacylglycerol to diacylglycerol (DAG). MGAT1 and MGAT2 are both implicated in obesity-related metabolic diseases. Conventional MGAT enzyme assays use radioactive substrates, wherein the product of the MGAT-catalyzed reaction is usually resolved by time-consuming thin layer chromatography (TLC) analysis. Furthermore, microsomal membrane preparations typically contain endogenous diacylglycerol acyltransferase (DGAT) from the host cells, and these DGAT activities can further acylate DAG to form triglyceride (TG). Our mass spectrometry (liquid chromatography-tandem mass spectrometry, or LC/MS/MS) MGAT2 assay measures human recombinant MGAT2-catalyzed formation of didecanoyl-glycerol from 1-decanoyl-rac-glycerol and decanoyl-CoA, to produce predominantly 1,3-didecanoyl-glycerol. Unlike 1,2-DAG, 1,3-didecanoyl-glycerol is proved to be not susceptible to further acylation to TG. 1,3-Didecanoyl-glycerol product can be readily solubilized and directly subjected to high-throughput mass spectrometry (HTMS) without further extraction in a 384-well format. We also have established the LC/MS/MS MGAT activity assay in the intestinal microsomes from various species. Our assay is proved to be highly sensitive, and thus it allows measurement of endogenous MGAT activity in cell lysates and tissue preparations. The implementation of the HTMS MGAT activity assay has facilitated the robust screening and evaluation of MGAT inhibitors for the treatment of metabolic diseases.

  8. Sensitivity and proportionality assessment of metabolites from microdose to high dose in rats using LC-MS/MS.

    PubMed

    Ni, Jinsong; Ouyang, Hui; Seto, Carmai; Sakuma, Takeo; Ellis, Robert; Rowe, Josh; Acheampong, Andrew; Welty, Devin; Szekely-Klepser, Gabriella

    2010-03-01

    The objective of this study was to evaluate the sensitivity requirement for LC-MS/MS as an analytical tool to characterize metabolites in plasma and urine at microdoses in rats and to investigate proportionality of metabolite exposure from a microdose of 1.67 µg/kg to a high dose of 5000 µg/kg for atorvastatin, ofloxacin, omeprazole and tamoxifen. Only the glucuronide metabolite of ofloxacin, the hydroxylation metabolite of omeprazole and the hydration metabolite of tamoxifen were characterized in rat plasma at microdose by LC-MS/MS. The exposure of detected metabolites of omeprazole and tamoxifen appeared to increase in a nonproportional manner with increasing doses. Exposure of ortho- and para-hydroxyatorvastatin, but not atorvastatin and lactone, increased proportionally with increasing doses. LC-MS/MS has demonstrated its usefulness for detecting and characterizing the major metabolites in plasma and urine at microdosing levels in rats. The exposure of metabolites at microdose could not simply be used to predict their exposure at higher doses.

  9. Liquid chromatography-mass spectrometry (LC-MS): a powerful combination for selenium speciation in garlic (Allium sativum).

    PubMed

    Dumont, Emmie; Ogra, Yasumitsu; Vanhaecke, Frank; Suzuki, Kazuo T; Cornelis, Rita

    2006-03-01

    Liquid chromatography (LC) hyphenated with both elemental and molecular mass spectrometry has been used for Se speciation in Se-enriched garlic. Different species were separated by ion-pair liquid chromatography-inductively coupled plasma mass spectrometry (LC-ICP-MS) after hot-water extraction. They were identified by on-line reversed-phase liquid chromatography-electrospray ionization tandem mass spectrometry (RPLC-ESI-MS-MS). Se-methionine and Se-methylselenocysteine were determined by monitoring their product ions. Another compound, gamma-glutamyl-Se-methylselenocysteine, shown to be the most abundant form of Se in the garlic, was determined without any additional sample pre-treatment after extraction and without the need for a synthesized standard. Product ions for this dipeptide were detected by LC-ESI-MS-MS for three isotopes of Se-78 Se, 80Se: and 82Se. The method was extended to the species extracted during in-vitro gastrointestinal digestion. Because both Se-methylselenocysteine and gamma-glutamyl-Se-methylselenocysteine have anticarcinogenic properties, their extractability and stability during human digestion are very important. Garlic was also treated with saliva, to enable detection and analysis of species extracted during mastication. Detailed information on the extractability of selenium species by both simulated gastric and intestinal fluid are given, and variation of the distribution of Se among the different species with time is discussed. Although the main species in garlic is the dipeptide gamma-glutamyl-Se-methylselenocysteine, Se-methylselenocysteine is the main compound present in the extracts after treatment with gastrointestinal fluids. Two more, so far unknown compounds were observed in the chromatogram. The extracted species and their transformations were analysed by combining LC-ICP-MS and LC-ESI-MS-MS. In both the simulated gastric and intestinal digests, Se-methionine, Se-methylselenocysteine, and gamma

  10. Tissue Localization of Glycosphingolipid Accumulation in a Gaucher Disease Mouse Brain by LC-ESI-MS/MS and High-Resolution MALDI Imaging Mass Spectrometry.

    PubMed

    Jones, E Ellen; Zhang, Wujuan; Zhao, Xueheng; Quiason, Cristine; Dale, Stephanie; Shahidi-Latham, Sheerin; Grabowski, Gregory A; Setchell, Kenneth D R; Drake, Richard R; Sun, Ying

    2017-12-01

    To better understand regional brain glycosphingolipid (GSL) accumulation in Gaucher disease (GD) and its relationship to neuropathology, a feasibility study using mass spectrometry and immunohistochemistry was conducted using brains derived from a GD mouse model (4L/PS/NA) homozygous for a mutant GCase (V394L [4L]) and expressing a prosaposin hypomorphic (PS-NA) transgene. Whole brains from GD and control animals were collected using one hemisphere for MALDI FTICR IMS analysis and the other for quantitation by LC-ESI-MS/MS. MALDI IMS detected several HexCers across the brains. Comparison with the brain hematoxylin and eosin (H&E) revealed differential signal distributions in the midbrain, brain stem, and CB of the GD brain versus the control. Quantitation of serial brain sections with LC-ESI-MS/MS supported the imaging results, finding the overall HexCer levels in the 4L/PS-NA brains to be four times higher than the control. LC-ESI-MS/MS also confirmed that the elevated hexosyl isomers were glucosylceramides rather than galactosylceramides. MALDI imaging also detected differential analyte distributions of lactosylceramide species and gangliosides in the 4L/PS-NA brain, which was validated by LC-ESI-MS/MS. Immunohistochemistry revealed regional inflammation, altered autophagy, and defective protein degradation correlating with regions of GSL accumulation, suggesting that specific GSLs may have distinct neuropathological effects.

  11. Chemometrically assisted development and validation of LC-MS/MS method for the analysis of potential genotoxic impurities in meropenem active pharmaceutical ingredient.

    PubMed

    Grigori, Katerina; Loukas, Yannis L; Malenović, Anđelija; Samara, Vicky; Kalaskani, Anastasia; Dimovasili, Efi; Kalovidouri, Magda; Dotsikas, Yannis

    2017-10-25

    A sensitive Liquid Chromatography tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantitative analysis of three potential genotoxic impurities (318BP, M9, S5) in meropenem Active Pharmaceutical Ingredient (API). Due to the requirement for LOD values in ppb range, a high concentration of meropenem API (30mg/mL) had to be injected. Therefore, efficient determination of meropenem from its impurities became a critical aim of this study, in order to divert meropenem to waste, via a switching valve. ‎ After the selection of the important factors affecting analytes' elution, a Box-Behnken design was utilized to set the plan of experiments conducted with UV detector. As responses, the separation factor s between the last eluting impurity and meropenem, as well as meropenem retention factor k were used. Grid point search methodology was implemented aiming to obtain the optimal conditions that simultaneously comply to the conflicted criteria. Optimal mobile phase consisted of ACN, methanol and 0.09% HCOOH at a ratio 71/3.5/15.5v/v. All impurities and internal standard omeprazole were eluted before 7.5min and at 8.0min the eluents were directed to waste. The protocol was transferred to LC-MS/MS and validated according to ICH guidelines. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Performance Evaluation and Online Realization of Data-driven Normalization Methods Used in LC/MS based Untargeted Metabolomics Analysis.

    PubMed

    Li, Bo; Tang, Jing; Yang, Qingxia; Cui, Xuejiao; Li, Shuang; Chen, Sijie; Cao, Quanxing; Xue, Weiwei; Chen, Na; Zhu, Feng

    2016-12-13

    In untargeted metabolomics analysis, several factors (e.g., unwanted experimental &biological variations and technical errors) may hamper the identification of differential metabolic features, which requires the data-driven normalization approaches before feature selection. So far, ≥16 normalization methods have been widely applied for processing the LC/MS based metabolomics data. However, the performance and the sample size dependence of those methods have not yet been exhaustively compared and no online tool for comparatively and comprehensively evaluating the performance of all 16 normalization methods has been provided. In this study, a comprehensive comparison on these methods was conducted. As a result, 16 methods were categorized into three groups based on their normalization performances across various sample sizes. The VSN, the Log Transformation and the PQN were identified as methods of the best normalization performance, while the Contrast consistently underperformed across all sub-datasets of different benchmark data. Moreover, an interactive web tool comprehensively evaluating the performance of 16 methods specifically for normalizing LC/MS based metabolomics data was constructed and hosted at http://server.idrb.cqu.edu.cn/MetaPre/. In summary, this study could serve as a useful guidance to the selection of suitable normalization methods in analyzing the LC/MS based metabolomics data.

  13. Performance Evaluation and Online Realization of Data-driven Normalization Methods Used in LC/MS based Untargeted Metabolomics Analysis

    PubMed Central

    Li, Bo; Tang, Jing; Yang, Qingxia; Cui, Xuejiao; Li, Shuang; Chen, Sijie; Cao, Quanxing; Xue, Weiwei; Chen, Na; Zhu, Feng

    2016-01-01

    In untargeted metabolomics analysis, several factors (e.g., unwanted experimental & biological variations and technical errors) may hamper the identification of differential metabolic features, which requires the data-driven normalization approaches before feature selection. So far, ≥16 normalization methods have been widely applied for processing the LC/MS based metabolomics data. However, the performance and the sample size dependence of those methods have not yet been exhaustively compared and no online tool for comparatively and comprehensively evaluating the performance of all 16 normalization methods has been provided. In this study, a comprehensive comparison on these methods was conducted. As a result, 16 methods were categorized into three groups based on their normalization performances across various sample sizes. The VSN, the Log Transformation and the PQN were identified as methods of the best normalization performance, while the Contrast consistently underperformed across all sub-datasets of different benchmark data. Moreover, an interactive web tool comprehensively evaluating the performance of 16 methods specifically for normalizing LC/MS based metabolomics data was constructed and hosted at http://server.idrb.cqu.edu.cn/MetaPre/. In summary, this study could serve as a useful guidance to the selection of suitable normalization methods in analyzing the LC/MS based metabolomics data. PMID:27958387

  14. The proposed biosynthesis of procyanidins by the comparative chemical analysis of five Camellia species using LC-MS

    PubMed Central

    Zhang, Liang; Tai, Yuling; Wang, Yijun; Meng, Qilu; Yang, Yunqiu; Zhang, Shihua; Yang, Hua; Zhang, Zhengzhu; Li, Daxiang; Wan, Xiaochun

    2017-01-01

    The genus Camellia (C.) contains many species, including C. sinensis, C. assamica, and C. taliensis, C. gymnogyna and C. tachangensis. The polyphenols of C. sinensis and C. assamica are flavan-3-ols monomers and their dimers and trimmers. However, the biosynthesis of procyanidins in Camellia genus remains unclear. In the present study, a comparative chemical analysis of flavan-3-ols, flavan-3-ols glycoside and procyanidins was conducted by high performance liquid chromatography (HPLC) and liquid chromatography diode array detection coupled with triple-quadrupole mass-spectrometry (LC-DAD-QQQ-MS). The results showed that C. tachangensis had a significant higher contents of (-)-epicatechin (EC) and (-)-epigallocatechin (EGC) compared with C. sinensis (p < 0.001). By contrast, higher levels of galloylated catechins were detected in C. sinensis. LC-DAD-MS/MS indicated that the main secondary metabolites of C. tachangensis were non-galloylated catechins, procyanidin dimers and trimers. Furthermore, (-)-epicatechin glucose (EC-glucose) and (-)-epigallocatechin glucose (EGC-glucose) were also abundant in C. tachangensis. A correlation analysis of EC-glucose and procyanidins dimers was conducted in five Camellia species. The levels of EC-glucose were closely related to the procyanidin dimers content. Thus, it was suggested that EC-glucose might be an important substrate for the biosynthesis of procyanidins. PMID:28383067

  15. Arsenic speciation and fucoxanthin analysis from seaweed dietary supplements using LC-MS.

    PubMed

    Avula, Bharathi; Wang, Yan-Hong; Khan, Ikhlas A

    2015-01-01

    The study involves the analysis of total arsenic (As) in metallic form, and organic and inorganic As species from seaweeds and dietary supplements. The analysis provides data for dietary exposure estimates of inorganic species that are considered more toxic to humans than organic and total As. Total As was determined by acid digestion followed by inductively coupled plasma (ICP)-MS. To characterize the As species, solvent extraction with sonication and microwave extraction using various aqueous and aqueous/organic solvent mixtures were initially evaluated. The optimum As speciation method was determined to be water extraction followed by anion exchange HPLC coupled with ICP-MS. Optimization of chromatographic conditions led to baseline separation for six As species, including As acid, arsenous acid, monomethylarsonic acid, dimethylarsinic acid, arsenobetaine, and arsenocholine, in approximately 8 min using gradient elution. Detection limits for all six compounds were in the range of 10-15 ng/mL. The data presented here will be valuable for the QA of analytical method development and surveys of total As and As species in dietary supplements. The most abundant As species found were arsenite [As(III)] and arsenate [As(V)]. The sum of inorganic As species present in the dietary supplements ranged from 1.2 to 31 μg/day. In addition, the dietary supplements purported to contain fucoxanthin, a carotenoid having pharmacological activities, were analyzed using ultra-performance LC-UV/MS.

  16. Aptamer based peptide enrichment for quantitative analysis of gonadotropin-releasing hormone by LC-MS/MS.

    PubMed

    Richards, S L; Cawley, A T; Cavicchioli, R; Suann, C J; Pickford, R; Raftery, M J

    2016-04-01

    Over recent years threats to racing have expanded to include naturally occurring biological molecules, such as peptides and proteins, and their synthetic analogues. Traditionally, antibodies have been used to enable detection of these compounds as they allow purification and concentration of the analyte of interest. The rapid expansion of peptide-based therapeutics necessitates a similarly rapid development of suitable antibodies or other means of enrichment. Potential alternative enrichment strategies include the use of aptamers, which offer the significant advantage of chemical synthesis once the nucleic acid sequence is known. A method was developed for the enrichment, detection and quantitation of gonadotropin-releasing hormone (GnRH) in equine urine using aptamer-based enrichment and LC-MS/MS. The method achieved comparable limits of detection (1 pg/mL) and quantification (2.5 pg/mL) to previously published antibody-based enrichment methods. The intra- and inter-assay precision achieved was less than 10% at both 5 and 20 pg/mL, and displayed a working dynamic range of 2.5-100 pg/mL. Significant matrix enhancement (170 ± 8%) and low analytical recovery (29 ± 15%) was observed, although the use of an isotopically heavy labelled GnRH peptide, GnRH (Pro(13)C5,(15)N), as the internal standard provides compensation for these parameters. Within the current limits of detection GnRH was detectable up to 1h post administration in urine and identification of a urinary catabolite extended this detection window to 4h. Based on the results of this preliminary investigation we propose the use of aptamers as a viable alternative to antibodies in the enrichment of peptide targets from equine urine. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. An advanced LC-MS (Q-TOF) technique for the detection of amino acids in atmospheric aerosols

    EPA Science Inventory

    Methodology for detection of native (underivitized) amino acids in atmospheric aerosols has been developed. This article describes the use of LC-MS (Q-TOF) and microwave-assisted gas phase hydrolysis for detection of free and combined amino acids in aerosols collected in a Southe...

  18. What Is in Your Wallet? Quantitation of Drugs of Abuse on Paper Currency with a Rapid LC-MS/MS Method

    ERIC Educational Resources Information Center

    Parker, Patrick D.; Beers, Brandon; Vergne, Matthew J.

    2017-01-01

    Laboratory experiments were developed to introduce students to the quantitation of drugs of abuse by high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). Undergraduate students were introduced to internal standard quantitation and the LC-MS/MS method optimization for cocaine. Cocaine extracted from paper currency was…

  19. Subnanogram proteomics: impact of LC column selection, MS instrumentation and data analysis strategy on proteome coverage for trace samples

    DOE PAGES

    Zhu, Ying; Zhao, Rui; Piehowski, Paul D.; ...

    2017-09-01

    One of the greatest challenges for mass spectrometry (MS)-based proteomics is the limited ability to analyze small samples. Here in this study, we investigate the relative contributions of liquid chromatography (LC), MS instrumentation and data analysis methods with the aim of improving proteome coverage for sample sizes ranging from 0.5 ng to 50 ng. We show that the LC separations utilizing 30-μm-i.d. columns increase signal intensity by >3-fold relative to those using 75-μm-i.d. columns, leading to 32% increase in peptide identifications. The Orbitrap Fusion Lumos MS significantly boosted both sensitivity and sequencing speed relative to earlier generation Orbitraps (e.g., LTQ-Orbitrap),more » leading to a ~3-fold increase in peptide identifications and 1.7-fold increase in identified protein groups for 2 ng tryptic digests of the bacterium S. oneidensis. The Match Between Runs algorithm of open-source MaxQuant software further increased proteome coverage by ~95% for 0.5 ng samples and by ~42% for 2 ng samples. Using the best combination of the above variables, we were able to identify >3,000 proteins from 10 ng tryptic digests from both HeLa and THP-1 mammalian cell lines. We also identified >950 proteins from subnanogram archaeal/bacterial cocultures. Finally, the present ultrasensitive LC-MS platform achieves a level of proteome coverage not previously realized for ultra-small sample loadings, and is expected to facilitate the analysis of subnanogram samples, including single mammalian cells.« less

  20. Proteomic analysis of sweet algerian apricot kernels (Prunus armeniaca L.) by combinatorial peptide ligand libraries and LC-MS/MS.

    PubMed

    Ghorab, Hamida; Lammi, Carmen; Arnoldi, Anna; Kabouche, Zahia; Aiello, Gilda

    2018-01-15

    An investigation on the proteome of the sweet kernel of apricot, based on equalisation with combinatorial peptide ligand libraries (CPLLs), SDS-PAGE, nLC-ESI-MS/MS, and database search, permitted identifying 175 proteins. Gene ontology analysis indicated that their main molecular functions are in nucleotide binding (20.9%), hydrolase activities (10.6%), kinase activities (7%), and catalytic activity (5.6%). A protein-protein association network analysis using STRING software permitted to build an interactomic map of all detected proteins, characterised by 34 interactions. In order to forecast the potential health benefits deriving from the consumption of these proteins, the two most abundant, i.e. Prunin 1 and 2, were enzymatically digested in silico predicting 10 and 14 peptides, respectively. Searching their sequences in the database BIOPEP, it was possible to suggest a variety of bioactivities, including dipeptidyl peptidase-IV (DPP-IV) and angiotensin converting enzyme I (ACE) inhibition, glucose uptake stimulation and antioxidant properties. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. RIBAVIRIN: The analysis of a polymorphic substance by LC-MS and FTIR spectroscopy

    NASA Astrophysics Data System (ADS)

    Machal, A. C.; Flurer, R. A.; Brueggemeyer, T. W.; Ellis, L. E.; Satzger, R. D.; Stewart, K. R.

    1998-06-01

    The FTIR laboratory often has the task of identifying unknown pharmaceuticals. This case involves unknown capsules received at the Forensic Chemistry Center. Through extensive searching of pharmaceutical data bases, it was concluded that the capsules might contain ribavirin, which is classified as an anti-viral agent. Mass spectral analysis (LC-MS) concluded that the capsules contained ribavirin; however, the FTIR results did not agree with the mass spectral results. Additional experiments were performed and the results demonstrate the capabilities of FTIR to discern differences between polymorphic forms of a substance, such as ribavirin, when other techniques are unable to provide this information.

  2. GlycReSoft: A Software Package for Automated Recognition of Glycans from LC/MS Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, Evan; Tan, Yan; Tan, Yuxiang

    2012-09-26

    Glycosylation modifies the physicochemical properties and protein binding functions of glycoconjugates. These modifications are biosynthesized in the endoplasmic reticulum and Golgi apparatus by a series of enzymatic transformations that are under complex control. As a result, mature glycans on a given site are heterogeneous mixtures of glycoforms. This gives rise to a spectrum of adhesive properties that strongly influences interactions with binding partners and resultant biological effects. In order to understand the roles glycosylation plays in normal and disease processes, efficient structural analysis tools are necessary. In the field of glycomics, liquid chromatography/mass spectrometry (LC/MS) is used to profile themore » glycans present in a given sample. This technology enables comparison of glycan compositions and abundances among different biological samples, i.e. normal versus disease, normal versus mutant, etc. Manual analysis of the glycan profiling LC/MS data is extremely time-consuming and efficient software tools are needed to eliminate this bottleneck. In this work, we have developed a tool to computationally model LC/MS data to enable efficient profiling of glycans. Using LC/MS data deconvoluted by Decon2LS/DeconTools, we built a list of unique neutral masses corresponding to candidate glycan compositions summarized over their various charge states, adducts and range of elution times. Our work aims to provide confident identification of true compounds in complex data sets that are not amenable to manual interpretation. This capability is an essential part of glycomics work flows. We demonstrate this tool, GlycReSoft, using an LC/MS dataset on tissue derived heparan sulfate oligosaccharides. The software, code and a test data set are publically archived under an open source license.« less

  3. Development of high-throughput multi-residue method for non-steroidal anti-inflammatory drugs monitoring in swine muscle by LC-MS/MS.

    PubMed

    Castilhos, Tamara S; Barreto, Fabiano; Meneghini, Leonardo; Bergold, Ana Maria

    2016-07-01

    A reliable and simple method for the detection and quantification of residues of 14 non-steroidal anti-inflammatory drugs and a metamizole metabolite in swine muscle was developed using liquid chromatography-electrospray ionisation-tandem mass spectrometry (LC-ESI-MS/MS). The samples were extracted with acetonitrile (ACN) in solid-liquid extraction followed by a low-temperature partitioning (LLE-LTP) process at -20 ± 2°C. After evaporation to dryness, the residue was reconstituted with hexane and a mixture of water:acetonitrile (1:1). LC separation was achieved on a reversed-phase (RP18) column with gradient elution using water (phase A) and ACN (phase B) both containing 1 mmol l(-)(1) ammonium acetate (NH4COO) with 0.025% acetic acid. Analysis was carried out on a triple-quadrupole tandem mass spectrometer (LC-MS/MS) in multiple reaction monitoring mode using an electrospray interface in negative and positive mode in a single run. Method validation was performed according to the criteria of Commission Decision No. 2002/657/EC. The matrix effect and linearity were evaluated. Decision limit (CCα), detection capability (CCβ), accuracy and repeatability of the method are also reported. The proposed method proved to be simple, easy and adequate for high-throughput analysis and was applied to routine analysis by the Brazilian Ministry of Agriculture, Livestock and Food Supply.

  4. Reduction of Solvent Effect in Reverse Phase Gradient Elution LC-ICP-MS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, Patrick Allen

    2005-12-17

    Quantification in liquid chromatography (LC) is becoming very important as more researchers are using LC, not as an analytical tool itself, but as a sample introduction system for other analytical instruments. The ability of LC instrumentation to quickly separate a wide variety of compounds makes it ideal for analysis of complex mixtures. For elemental speciation, LC is joined with inductively coupled plasma mass spectrometry (ICP-MS) to separate and detect metal-containing, organic compounds in complex mixtures, such as biological samples. Often, the solvent gradients required to perform complex separations will cause matrix effects within the plasma. This limits the sensitivity ofmore » the ICP-MS and the quantification methods available for use in such analyses. Traditionally, isotope dilution has been the method of choice for LC-ICP-MS quantification. The use of naturally abundant isotopes of a single element in quantification corrects for most of the effects that LC solvent gradients produce within the plasma. However, not all elements of interest in speciation studies have multiple naturally occurring isotopes; and polyatomic interferences for a given isotope can develop within the plasma, depending on the solvent matrix. This is the case for reverse phase LC separations, where increasing amounts of organic solvent are required. For such separations, an alternative to isotope dilution for quantification would be is needed. To this end, a new method was developed using the Apex-Q desolvation system (ESI, Omaha, NE) to couple LC instrumentation with an ICP-MS device. The desolvation power of the system allowed greater concentrations of methanol to be introduced to the plasma prior to destabilization than with direct methanol injection into the plasma. Studies were performed, using simulated and actual linear methanol gradients, to find analyte-internal standard (AIS) pairs whose ratio remains consistent (deviations {+-} 10%) over methanol concentration ranges

  5. HR-LC-MS based analysis of two antibacterial metabolites from a marine sponge symbiont Streptomyces pharmamarensis ICN40.

    PubMed

    Joseph, Francis-Joseph Rosemary Sharmila; Iniyan, Appadurai Muthamil; Vincent, Samuel Gnana Prakash

    2017-10-01

    On the effort to screen antibiotics against Methicillin resistant Staphylococcus aureus (MRSA), an actinomycete strain which can produce bactericidal compound was isolated from a marine sponge of Kanyakumari Coast, India. Two anti-MRSA compounds (PVI401 and PVI402) were isolated from the fermentation plates of Streptomyces pharmamarensis ICN40. TLC bioautography analysis yielded two active spots with Rf value of 0.75 (PVI401) and 0.8 (PVI402) from the crude extract. Both the compounds were characterized by HR-LC-MS analysis. LC-MS based de-replication analysis found out the compound PVI401 with an exact mass of 376.09435 Da and PVI402 with an exact mass of 273.26795 Da were found to be unidentified. Antibacterial spectrum showed significant minimal inhibitory concentration as 0.5 μg/ml of PVI401 and 2 μg/ml of PVI402 against MRSA. The whole organism zebrafish safety evaluation exhibited the compound PVI402 is safe upto 1 mg/ml 40 μg/ml of PVI401 exhibited thrombosis in cardiac chamber and this compound exhibited 44 μg/ml of LC 50 against HepG2 hepatic carcinoma cell line. Both the compounds may be identified further for its structural novelty and clinical studies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Analysis of oxcarbazepine and the 10-hydroxycarbazepine enantiomers in plasma by LC-MS/MS: application in a pharmacokinetic study.

    PubMed

    de Jesus Antunes, Natalicia; Wichert-Ana, Lauro; Coelho, Eduardo Barbosa; Della Pasqua, Oscar; Alexandre, Veriano; Takayanagui, Osvaldo Massaiti; Tozatto, Eduardo; Lanchote, Vera Lucia

    2013-12-01

    Oxcarbazepine is a second-generation antiepileptic drug indicated as monotherapy or adjunctive therapy in the treatment of partial seizures or generalized tonic-clonic seizures in adults and children. It undergoes rapid presystemic reduction with formation of the active metabolite 10-hydroxycarbazepine (MHD), which has a chiral center at position 10, with the enantiomers (S)-(+)- and R-(-)-MHD showing similar antiepileptic effects. This study presents the development and validation of a method of sequential analysis of oxcarbazepine and MHD enantiomers in plasma using liquid chromatography with tandem mass spectrometry (LC-MS/MS). Aliquots of 100 μL of plasma were extracted with a mixture of methyl tert-butyl ether: dichloromethane (2:1). The separation of oxcarbazepine and the MHD enantiomers was obtained on a chiral phase Chiralcel OD-H column, using a mixture of hexane:ethanol:isopropanol (80:15:5, v/v/v) as mobile phase at a flow rate of 1.3 mL/min with a split ratio of 1:5, and quantification was performed by LC-MS/MS. The limit of quantification was 12.5 ng oxcarbazepine and 31.25 ng of each MHD enantiomer/mL of plasma. The method was applied in the study of kinetic disposition of oxcarbazepine and the MHD enantiomers in the steady state after oral administration of 300 mg/12 h oxcarbazepine in a healthy volunteer. The maximum plasma concentration of oxcarbazepine was 1.2 µg/mL at 0.75 h. The kinetic disposition of MHD is enantioselective, with a higher proportion of the S-(+)-MHD enantiomer compared to R-(-)-MHD and an AUC(0-12) S-(+)/R-(-) ratio of 5.44. © 2013 Wiley Periodicals, Inc.

  7. Design of five-layer gold nanoparticles self-assembled in a liquid open tubular column for ultrasensitive nano-LC-MS/MS proteomic analysis of 80 living cells.

    PubMed

    Shao, Xi; Zhang, Xiangmin

    2017-04-01

    In this work, for the first time, a liquid open tubular column modified by five-layer gold nanoparticles and linked with C 18 (GNPs@C 18 ) was designed and fabricated for nano-LC-MS/MS analysis of 80 living cells. Sixty nanometer gold nanoparticles were self-assembled layer by layer on the inner wall of a 20 μm id fused-silica capillary. C 18 was then linked on the gold nanoparticles to make the liquid open tubular column show hydrophobic character. Enough loading capacities for analysis of 80 living cells, ∼100 fmol for pk-10 and ∼30 fmol for insulin, were obtained with the 2 m × 20 μm id five-layer GNPs@C 18 open tubular column. The open tubular column was used in an online pretreatment and direct nano-LC-MS/MS analysis system to analyze 80 living HepG2 cells. In total, 650 proteins were identified in triplicate runs. The subcellular localization of the identified proteins showed that our system had no bias toward different cellular compartments. Protein copy number per cell of the identified proteins showed that the detection limit could reach 50 zmol and the abundance of the identified proteins could cover a dynamic range of 6 orders. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Bisphenol A release from an orthodontic resin composite: A GC/MS and LC/MS study.

    PubMed

    Deviot, Marc; Lachaise, Isabelle; Högg, Christof; Durner, Jürgen; Reichl, Franz-Xaver; Attal, Jean-Pierre; Dursun, Elisabeth

    2018-02-01

    First, to analyse the in vitro release of BPA and Bis-GMA from an orthodontic resin composite (Transbond XT, 3M Unitek), stored in various conditions, by gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS); then to extrapolate the data to the clinical situation. Secondly, to explore the thermal stability of Bis-GMA. Cylinders of resin composite were prepared and stored according to 3 different protocols: (1) they were light-cured 20s, then placed in artificial saliva; (2) they were light-cured 2s, then placed in acetonitrile; (3) they were light-cured 2s, then placed in methanol. For each group, BPA and Bis-GMA release were determined with GC/MS and/or LC/MS at least after one week. Besides, 120 brackets (10 of each type) were bonded over metal teeth, then debonded, and the weight and the surface of resin composite residues were measured. BPA and Bis-GMA release of adhesive residues were extrapolated from the data obtained with the cylinders. Besides, BPA release from a heated Bis-GMA solution was measured. With GC/MC, BPA was detected in all samples. With LC/MS, BPA was detected only from samples immersed in MeOH; Bis-GMA was detected, in varying amount according to the extraction media and the light-curing time. BPA was found after heating of the Bis-GMA solution. Contamination risk and the heat applied in GC/MS may overestimate the BPA release from resin composite. Based on the LC/MS results, the risk of BPA release after orthodontic bonding would be more than 42000 times lower than the TDI for a 30-kg child. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  9. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) for analysis of endogenous steroids in the luteal phase and early pregnancy in dogs: a pilot study.

    PubMed

    Holst, Bodil S; Kushnir, Mark M; Bergquist, Jonas

    2015-12-01

    Blood samples from dogs are often limited in volume, only allowing few steroids to be quantified with immunoassays. In addition, immunoassays may be compromised by interferences such as anti-reagent antibodies. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) can be used for the simultaneous quantitation of several steroids. This has not been described in dogs before. The aims were to use LC-MS/MS to study steroid profiles in early pregnancy and luteal phase in dogs, and to determine if differences exist between pregnant (P) and nonpregnant (NP) dogs. Nine female dogs were included, 4 during a NP luteal phase, 4 during a P luteal phase, and one during one NP and one P luteal phase. Blood samples were collected around the time of the LH surge (Day 0) and on Day 26. Serum was analyzed for 5 classes of steroids, including glucocorticoids, androgens, estrogens, pregnanes, and progestins, using LC-MS/MS methods. The concentration of progesterone was significantly higher on Day 26 in P than in NP bitches. Distribution of concentrations of glucocorticoids, androgens, estrogens, or pregnanes in P and NP dogs were not statistically different. The predominating glucocorticoid was cortisol, and dihydroepiandrosterone (DHEA) was the predominating androgen. Concentration of estrone was comparable to oestradiol, whereas concentrations of pregnenolone were higher than those of 17-OH pregnenolone. Only concentration of progesterone differed between P and NP bitches, being significantly higher on Day 26 in P than in NP bitches. LC-MS/MS offers interesting possibilities for studies of canine reproductive endocrinology. © 2015 American Society for Veterinary Clinical Pathology.

  10. Post-acquisition data mining techniques for LC-MS/MS-acquired data in drug metabolite identification.

    PubMed

    Dhurjad, Pooja Sukhdev; Marothu, Vamsi Krishna; Rathod, Rajeshwari

    2017-08-01

    Metabolite identification is a crucial part of the drug discovery process. LC-MS/MS-based metabolite identification has gained widespread use, but the data acquired by the LC-MS/MS instrument is complex, and thus the interpretation of data becomes troublesome. Fortunately, advancements in data mining techniques have simplified the process of data interpretation with improved mass accuracy and provide a potentially selective, sensitive, accurate and comprehensive way for metabolite identification. In this review, we have discussed the targeted (extracted ion chromatogram, mass defect filter, product ion filter, neutral loss filter and isotope pattern filter) and untargeted (control sample comparison, background subtraction and metabolomic approaches) post-acquisition data mining techniques, which facilitate the drug metabolite identification. We have also discussed the importance of integrated data mining strategy.

  11. A comparative analysis of human plasma and serum proteins by combining native PAGE, whole-gel slicing and quantitative LC-MS/MS: Utilizing native MS-electropherograms in proteomic analysis for discovering structure and interaction-correlated differences.

    PubMed

    Wen, Meiling; Jin, Ya; Manabe, Takashi; Chen, Shumin; Tan, Wen

    2017-12-01

    MS identification has long been used for PAGE-separated protein bands, but global and systematic quantitation utilizing MS after PAGE has remained rare and not been reported for native PAGE. Here we reported on a new method combining native PAGE, whole-gel slicing and quantitative LC-MS/MS, aiming at comparative analysis on not only abundance, but also structures and interactions of proteins. A pair of human plasma and serum samples were used as test samples and separated on a native PAGE gel. Six lanes of each sample were cut, each lane was further sliced into thirty-five 1.1 mm × 1.1 mm squares and all the squares were subjected to standardized procedures of in-gel digestion and quantitative LC-MS/MS. The results comprised 958 data rows that each contained abundance values of a protein detected in one square in eleven gel lanes (one plasma lane excluded). The data were evaluated to have satisfactory reproducibility of assignment and quantitation. Totally 315 proteins were assigned, with each protein assigned in 1-28 squares. The abundance distributions in the plasma and serum gel lanes were reconstructed for each protein, named as "native MS-electropherograms". Comparison of the electropherograms revealed significant plasma-versus-serum differences on 33 proteins in 87 squares (fold difference > 2 or < 0.5, p < 0.05). Many of the differences matched with accumulated knowledge on protein interactions and proteolysis involved in blood coagulation, complement and wound healing processes. We expect this method would be useful to provide more comprehensive information in comparative proteomic analysis, on both quantities and structures/interactions. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Characterization and identification of proteases secreted by Aspergillus fumigatus using free flow electrophoresis and MS.

    PubMed

    Neustadt, Madlen; Costina, Victor; Kupfahl, Claudio; Buchheidt, Dieter; Eckerskorn, Christoph; Neumaier, Michael; Findeisen, Peter

    2009-06-01

    Early diagnosis of life-threatening invasive aspergillosis in neutropenic patients remains challenging because current laboratory methods have limited diagnostic sensitivity and/or specificity. Aspergillus species are known to secrete various pathogenetically relevant proteases and the monitoring of their protease activity in serum specimens might serve as a new diagnostic approach.For the characterization and identification of secreted proteases, the culture supernatant of Aspergillus fumigatus was fractionated using free flow electrophoresis (Becton Dickinson). Protease activity of separated fractions was measured using fluorescently labeled reporter peptides. Fractions were also co-incubated in parallel with various protease inhibitors that specifically inhibit a distinct class of proteases e.g. metallo- or cysteine-proteases. Those fractions with high protease activity were further subjected to LC-MS/MS analysis for protease identification. The highest protease activity was measured in fractions with an acidic pH range. The results of the 'inhibitor-panel' gave a clear indication that it is mainly metallo- and serine-proteases that are involved in the degradation of reporter peptides. Furthermore, several proteases were identified that facilitate the optimization of reporter peptides for functional protease profiling as a diagnostic tool for invasive aspergillosis.

  13. LC-MS/MS quantification of free and Fab-bound colchicine in plasma, urine and organs following colchicine administration and colchicine-specific Fab fragments treatment in Göttingen minipigs.

    PubMed

    Fabresse, Nicolas; Allard, Julien; Sardaby, Marine; Thompson, Adrian; Clutton, R Eddie; Eddleston, Michael; Alvarez, Jean-Claude

    2017-08-15

    Clinical evaluation of a colchicine specific antigen-binding fragment (Fab) in order to treat colchicine poisoning required the development of an accurate method allowing quantification of free and Fab-bound colchicine in plasma and urine, and free colchicine in tissues, to measure colchicine redistribution after Fab administration. Three methods have been developed for this purpose, and validated in plasma, urine and liver: total colchicine was determined after denaturation of Fab by dilution in water and heating; free colchicine was separated from Fab-bound colchicine by filtration with 30KDa micro-filters; tissues were homogenized in a tissue mixer. Deuterated colchicine was used as internal standard. Samples were extracted by liquid-liquid extraction and analyzed with a LC-MS/MS. LOQ were 0.5ng/mL in plasma and urine for free and total colchicine and 5pg/mg in tissues. The methods were linear in the 0.5-100ng/mL range in plasma and urine, and 5-300pg/mg in tissues with determination coefficients>0.99. Precision and accuracy of QC samples presented a CV<9.4%. The methods require only 200μL of sample and allow a high throughput due to short analytical run (2min). These methods were successfully applied to a pig intoxicated with colchicine and treated with colchicine specific Fab fragments. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Development and validation of a serum total testosterone liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay calibrated to NIST SRM 971.

    PubMed

    French, Deborah

    2013-01-16

    At our institution, serum testosterone in adult males is measured by immunoassay while female and pediatric specimens are sent to a reference laboratory for liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis due to low concentrations. As this is of significant cost, a testosterone LC-MS/MS assay was developed in-house. A 5500 QTRAP® using electrospray ionization and a Shimadzu Prominence with a C18 column were used. Gradient elution with formic acid, water and methanol:acetonitrile at 0.5 ml/min had a 7-min run-time. A liquid-liquid extraction with hexane:ethyl acetate was carried out on 200 μl of serum. Multiple reaction monitoring was employed. Sample preparation took ~80 min for 21 samples. Six calibrators were used (0-1263 ng/dl; concentration assigned by NIST SRM 971) with 3 quality controls (9, 168 and 532 ng/dl). The limits of detection and quantitation were 1 and 2 ng/dl respectively. Extraction recovery was ~90% and ion suppression ~5%. Within-run and total precision studies yielded <15% CV at the limit of quantitation and <7% CV through the rest of the linear range. Isobaric interferences were baseline separated from testosterone. Method comparisons between this assay, an immunoassay, and another LC-MS/MS assay were completed. An accurate and sensitive LC-MS/MS assay for total testosterone was developed. Bringing this assay in-house reduces turnaround time for clinicians and patients and saves our institution funds. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Metabolomic analysis-Addressing NMR and LC-MS related problems in human feces sample preparation.

    PubMed

    Moosmang, Simon; Pitscheider, Maria; Sturm, Sonja; Seger, Christoph; Tilg, Herbert; Halabalaki, Maria; Stuppner, Hermann

    2017-10-31

    Metabolomics is a well-established field in fundamental clinical research with applications in different human body fluids. However, metabolomic investigations in feces are currently an emerging field. Fecal sample preparation is a demanding task due to high complexity and heterogeneity of the matrix. To gain access to the information enclosed in human feces it is necessary to extract the metabolites and make them accessible to analytical platforms like NMR or LC-MS. In this study different pre-analytical parameters and factors were investigated i.e. water content, different extraction solvents, influence of freeze-drying and homogenization, ratios of sample weight to extraction solvent, and their respective impact on metabolite profiles acquired by NMR and LC-MS. The results indicate that profiles are strongly biased by selection of extraction solvent or drying of samples, which causes different metabolites to be lost, under- or overstated. Additionally signal intensity and reproducibility of the measurement were found to be strongly dependent on sample pre-treatment steps: freeze-drying and homogenization lead to improved release of metabolites and thus increased signals, but at the same time induced variations and thus deteriorated reproducibility. We established the first protocol for extraction of human fecal samples and subsequent measurement with both complementary techniques NMR and LC-MS. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Multimycotoxin LC-MS/MS Analysis in Tea Beverages after Dispersive Liquid-Liquid Microextraction (DLLME).

    PubMed

    Pallarés, Noelia; Font, Guillermina; Mañes, Jordi; Ferrer, Emilia

    2017-11-29

    The aim of the present study was to develop a multimycotoxin liquid chromatography tandem mass spectrometry (LC-MS/MS) method with a dispersive liquid-liquid microextraction procedure (DLLME) for the analysis of AFs, 3aDON, 15aDON, NIV, HT-2, T-2, ZEA, OTA, ENNs, and BEA in tea beverages and to evaluate their mycotoxin contents. The proposed method was characterized in terms of linearity, limits of detection (LODs), limits of quantification (LOQs), recoveries, repeatability (intraday precision), reproducibility (interday precision), and matrix effects to check suitability. The results show LODs in the range of 0.05-10 μg/L, LOQs in the range of 0.2-33 μg/L, and recoveries in the range of 65-127% (RSD < 20%). The method developed in this study was applied to 44 commercial samples of black tea, red tea, green tea, and green mint tea. The results show that, of the analyzed mycotoxins, AFB2, AFG2, 15aDON, AFG1, and ENB were detected in the samples. AFB2 (14.4-32.2 μg/L) and 15aDON (60.5-61 μg/L) presented the highest levels. Green mint tea contained the highest concentration of mycotoxins. The risk assessment study shows that the population is not much exposed to mycotoxins through the consumption of tea beverages.

  17. Simultaneous Quantification of Free Cholesterol, Cholesteryl Esters, and Triglycerides without Ester Hydrolysis by UHPLC Separation and In-Source Collision Induced Dissociation Coupled MS/MS

    NASA Astrophysics Data System (ADS)

    Gardner, Michael S.; McWilliams, Lisa G.; Jones, Jeffrey I.; Kuklenyik, Zsuzsanna; Pirkle, James L.; Barr, John R.

    2017-08-01

    We demonstrate the application of in-source nitrogen collision-induced dissociation (CID) that eliminates the need for ester hydrolysis before simultaneous analysis of esterified cholesterol (EC) and triglycerides (TG) along with free cholesterol (FC) from human serum, using normal phase liquid chromatography (LC) coupled to atmospheric pressure chemical ionization (APCI) tandem mass spectrometry (MS/MS). The analysis requires only 50 μL of 1:100 dilute serum with a high-throughput, precipitation/evaporation/extraction protocol in one pot. Known representative mixtures of EC and TG species were used as calibrators with stable isotope labeled analogs as internal standards. The APCI MS source was operated with nitrogen source gas. Reproducible in-source CID was achieved with the use of optimal cone voltage (declustering potential), generating FC, EC, and TG lipid class-specific precursor fragment ions for multiple reaction monitoring (MRM). Using a representative mixture of purified FC, CE, and TG species as calibrators, the method accuracy was assessed with analysis of five inter-laboratory standardization materials, showing -10% bias for Total-C and -3% for Total-TG. Repeated duplicate analysis of a quality control pool showed intra-day and inter-day variation of 5% and 5.8% for FC, 5.2% and 8.5% for Total-C, and 4.1% and 7.7% for Total-TG. The applicability of the method was demonstrated on 32 serum samples and corresponding lipoprotein sub-fractions collected from normolipidemic, hypercholesterolemic, hypertriglyceridemic, and hyperlipidemic donors. The results show that in-source CID coupled with isotope dilution UHPLC-MS/MS is a viable high precision approach for translational research studies where samples are substantially diluted or the amounts of archived samples are limited. [Figure not available: see fulltext.

  18. Complete LC/MS analysis of a Tinnevelli senna pod extract and subsequent isolation and identification of two new benzophenone glucosides.

    PubMed

    Terreaux, Christian; Wang, Qi; Ioset, Jean-Robert; Ndjoko, Karine; Grimminger, Wolf; Hostettmann, Kurt

    2002-04-01

    The hydroalcoholic extract of Tinnevelli senna is widely used as a laxative phytomedicine. In order to improve the knowledge of the chemical composition of this extract, LC/MS and LC/MS(n) studies were performed, allowing the on-line identification of most of the known constituents, i. e., flavonoids, anthraquinones and the typical dianthronic sennosides. However, the identity of four compounds could not be ascertained on-line under the given LC/MS conditions. These substances were isolated and their structures elucidated as kaempferol, the naphthalene derivative tinnevellin 8-glucoside and two new carboxylated benzophenone glucosides.

  19. Analysis of hydraulic fracturing additives by LC/Q-TOF-MS.

    PubMed

    Ferrer, Imma; Thurman, E Michael

    2015-08-01

    The chemical additives used in fracturing fluids can be used as tracers of water contamination caused by hydraulic fracturing operations. For this purpose, a complete chemical characterization is necessary using advanced analytical techniques. Liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (LC/Q-TOF-MS) was used to identify chemical additives present in flowback and produced waters. Accurate mass measurements of main ions and fragments were used to characterize the major components of fracking fluids. Sodium adducts turned out to be the main molecular adduct ions detected for some additives due to oxygen-rich structures. Among the classes of chemical components analyzed by mass spectrometry include gels (guar gum), biocides (glutaraldehyde and alkyl dimethyl benzyl ammonium chloride), and surfactants (cocamidopropyl dimethylamines, cocamidopropyl hydroxysultaines, and cocamidopropyl derivatives). The capabilities of accurate mass and MS-MS fragmentation are explored for the unequivocal identification of these compounds. A special emphasis is given to the mass spectrometry elucidation approaches used to identify a major class of hydraulic fracturing compounds, surfactants.

  20. Analysis of pesticide residues in strawberries and soils by GC-MS/MS, LC-MS/MS and two-dimensional GC-time-of-flight MS comparing organic and integrated pest management farming.

    PubMed

    Fernandes, Virgínia C; Lehotay, Steven J; Geis-Asteggiante, Lucía; Kwon, Hyeyoung; Mol, Hans G J; van der Kamp, Henk; Mateus, Nuno; Domingues, Valentina F; Delerue-Matos, Cristina

    2014-01-01

    This study analysed 22 strawberry and soil samples after their collection over the course of 2 years to compare the residue profiles from organic farming with integrated pest management practices in Portugal. For sample preparation, we used the citrate-buffered version of the quick, easy, cheap, effective, rugged, and safe (QuEChERS) method. We applied three different methods for analysis: (1) 27 pesticides were targeted using LC-MS/MS; (2) 143 were targeted using low pressure GC-tandem mass spectrometry (LP-GC-MS/MS); and (3) more than 600 pesticides were screened in a targeted and untargeted approach using comprehensive, two-dimensional gas chromatography time-of-flight mass spectrometry (GC × GC-TOF-MS). Comparison was made of the analyses using the different methods for the shared samples. The results were similar, thereby providing satisfactory confirmation of both similarly positive and negative findings. No pesticides were found in the organic-farmed samples. In samples from integrated pest management practices, nine pesticides were determined and confirmed to be present, ranging from 2 µg kg(-1) for fluazifop-p-butyl to 50 µg kg(-1) for fenpropathrin. Concentrations of residues in strawberries were less than European maximum residue limits.

  1. LC-MS/MS-based approach for obtaining exposure estimates of metabolites in early clinical trials using radioactive metabolites as reference standards.

    PubMed

    Zhang, Donglu; Raghavan, Nirmala; Chando, Theodore; Gambardella, Janice; Fu, Yunlin; Zhang, Duxi; Unger, Steve E; Humphreys, W Griffith

    2007-12-01

    An LC-MS/MS-based approach that employs authentic radioactive metabolites as reference standards was developed to estimate metabolite exposures in early drug development studies. This method is useful to estimate metabolite levels in studies done with non-radiolabeled compounds where metabolite standards are not available to allow standard LC-MS/MS assay development. A metabolite mixture obtained from an in vivo source treated with a radiolabeled compound was partially purified, quantified, and spiked into human plasma to provide metabolite standard curves. Metabolites were analyzed by LC-MS/MS using the specific mass transitions and an internal standard. The metabolite concentrations determined by this approach were found to be comparable to those determined by valid LC-MS/MS assays. This approach does not requires synthesis of authentic metabolites or the knowledge of exact structures of metabolites, and therefore should provide a useful method to obtain early estimates of circulating metabolites in early clinical or toxicological studies.

  2. Measurement of methionine level with the LC-ESI-MS/MS method in schizophrenic patients.

    PubMed

    Kulaksizoglu, S; Kulaksizoglu, B; Ellidag, H Y; Eren, E; Yilmaz, N; Baykal, A

    2016-01-01

    The purpose of this study was to evaluate plasma methionine levels by using liquid chromatography electrospray ionization-tandem mass spectroscopy (LC-ESI-MS/MS) in schizophrenic patients. A twelve-point standard graph was drawn, and the recovery rate, the intra-day and inter-day coefficients of variation (CV), the limit of detection (LOD), and the limit of quantification (LOQ) were evaluated. The y and R2 values of the standard graph equation were determined as 0.011x + 0.0179 and 0.9989, respectively, and the graph remained linear until the 200 µmol/l level. The intra-day coefficients of variation of the samples (n = 10) containing 8, 28, and 58 µmol/l methionine were determined as 2.68, 3.10, and 3.79%, respectively; while their inter-day coefficients of variation were determined as 2.98, 3.19, and 3.84%. The LOD and LOQ values were determined as 0.04 and 0.1 µmol/l, respectively, while the mean recovery rates were determined as 101.7 and 99.3%. Plasma methionine values were measured as 21.5 (19.5-24,6) µmol/l for the patient group, 17.8 (16.3-20.1) µmol/l for the control group, and the difference between the two groups was statistically significant (p = 0.03). LC-ESI-MS/MS method represents a fairly sensitive, economic, and rapid analysis that requires very little sample and is suitable for measuring methionine levels in schizophrenic patients.

  3. MEASUREMENT OF OXIDATIVE STRESS PARAMETERS USING LIQUID CHROMATOGRAPHY - TANDEM MASS SPECTROSCOPY (LC-MS/MS)

    EPA Science Inventory

    What is the study?
    An invited review article. Measurement of oxidative stress parameters using liquid chromatography-tandem mass spectroscopy (LC-MS/MS)
    Why was it done?
    Although oxidative stress is frequently cited as a cause of various adverse biological eff...

  4. Recent (2000-2015) developments in the analysis of minor unknown natural products based on characteristic fragment information using LC-MS.

    PubMed

    Cai, Tian; Guo, Ze-Qin; Xu, Xiao-Ying; Wu, Zhi-Jun

    2018-03-01

    Liquid chromatography-Mass Spectrometry (LC-MS) has been widely used in natural product analysis. Global detection and identification of nontargeted components are desirable in natural product research, for example, in quality control of Chinese herbal medicine. Nontargeted components analysis continues to expand to exciting life science application domains such as metabonomics. With this background, the present review summarizes recent developments in the analysis of minor unknown natural products using LC-MS and mainly focuses on the determination of the molecular formulae, selection of precursor ions, and characteristic fragmentation patterns of the known compounds. This review consists of three parts. Firstly, the methods used to determine unique molecular formula of unknown compounds such as accurate mass measurements, MS n spectra, or relative isotopic abundance information, are introduced. Secondly, the methods improving signal-to-noise ratio of MS/MS spectra by manual-MS/MS or workflow targeting-only signals were elucidated; pure precursor ions can be selected by changing the precursor ion isolated window. Lastly, characteristic fragmentation patterns such as Retro-Diels-Alder (RDA), McLafferty rearrangements, "internal residue loss," and so on, occurring in the molecular ions of natural products are summarized. Classical application of characteristic fragmentation patterns in identifying unknown compounds in extracts and relevant fragmentation mechanisms are presented (RDA reactions occurring readily in the molecular ions of flavanones or isoflavanones, McLafferty-type fragmentation reactions of some natural products such as epipolythiodioxopiperazines; fragmentation by "internal residue loss" possibly involving ion-neutral complex intermediates). © 2016 Wiley Periodicals, Inc. Mass Spec Rev 37:202-216, 2018. © 2016 Wiley Periodicals, Inc.

  5. Comparability analysis of protein therapeutics by bottom-up LC-MS with stable isotope-tagged reference standards.

    PubMed

    Manuilov, Anton V; Radziejewski, Czeslaw H; Lee, David H

    2011-01-01

    Comparability studies lie at the heart of assessments that evaluate differences amongst manufacturing processes and stability studies of protein therapeutics. Low resolution chromatographic and electrophoretic methods facilitate quantitation, but do not always yield detailed insight into the effect of the manufacturing change or environmental stress. Conversely, mass spectrometry (MS) can provide high resolution information on the molecule, but conventional methods are not very quantitative. This gap can be reconciled by use of a stable isotope-tagged reference standard (SITRS), a version of the analyte protein that is uniformly labeled (13)C6-arginine and (13)C6-lysine. The SITRS serves as an internal control that is trypsin-digested and analyzed by liquid chromatography (LC)-MS with the analyte sample. The ratio of the ion intensities of each unlabeled and labeled peptide pair is then compared to that of other sample(s). A comparison of these ratios provides a readily accessible way to spot even minute differences among samples. In a study of a monoclonal antibody (mAb) spiked with varying amounts of the same antibody bearing point mutations, peptides containing the mutations were readily identified and quantified at concentrations as low as 2% relative to unmodified peptides. The method is robust, reproducible and produced a linear response for every peptide that was monitored. The method was also successfully used to distinguish between two batches of a mAb that were produced in two different cell lines while two batches produced from the same cell line were found to be highly comparable. Finally, the use of the SITRS method in the comparison of two stressed mAb samples enabled the identification of sites susceptible to deamidation and oxidation, as well as their quantitation. The experimental results indicate that use of a SITRS in a peptide mapping experiment with MS detection enables sensitive and quantitative comparability studies of proteins at high

  6. Application of HRAM screening and LC-MS/MS confirmation of active pharmaceutical ingredient in "natural" herbal supplements.

    PubMed

    Pascali, Jennifer P; Fais, Paolo; Vaiano, Fabio; Bertol, Elisabetta

    2018-05-01

    The growing market of herbal remedies worldwide could pose severe problems to consumers' health due to the possible presence of potentially harmful, undeclared synthetic substances or analogues of prescription drugs. The present work shows a simple but effective approach to unequivocally identify synthetic anorectic compounds in allegedly 'natural' herbal extracts, by exploiting liquid chromatography/time of flight (Q-TOF LC/MS) technology coupled to liquid chromatography/triple quadrupole (LC-MS/MS) confirmation and quantitation. The procedure was applied to five tea herbal extracts and pills sold as coadjutant for weigh loss. The method exploited liquid-liquid sample extraction (LLE) and separation in a C18 (2.1mm×150mm, 1.8μm) column. QTOF acquisitions were carried out both in scan mode and all ion MS/MS mode and results were obtained after search against ad hoc prepared library. Sibutramine, 4-hydroxyamphetamine, caffeine and theophylline were preliminary identified samples. Confirmation and quantitation of the preliminary identified compounds were obtained in LC-MS/MS after preparation of appropriated standards. Sibutramine, caffeine and theophylline were finally confirmed and quantitate. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Microfluidic LC Device with Orthogonal Sample Extraction for On-Chip MALDI-MS Detection

    PubMed Central

    Lazar, Iulia M.; Kabulski, Jarod L.

    2013-01-01

    A microfluidic device that enables on-chip matrix assisted laser desorption ionization-mass spectrometry (MALDI-MS) detection for liquid chromatography (LC) separations is described. The device comprises an array of functional elements to carry out LC separations, integrates a novel microchip-MS interface to facilitate the orthogonal transposition of the microfluidic LC channel into an array of reservoirs, and enables sensitive MALDI-MS detection directly from the chip. Essentially, the device provides a snapshot MALDI-MS map of the content of the separation channel present on the chip. The detection of proteins with biomarker potential from MCF10A breast epithelial cell extracts, and detection limits in the low fmol range, are demonstrated. In addition, the design of the novel LC-MALDI-MS chip entices the promotion of a new concept for performing sample separations within the limited time-frame that accompanies the dead-volume of a separation channel. PMID:23592150

  8. Untargeted LC-MS/MS Profiling of Cell Culture Media Formulations for Evaluation of High Temperature Short Time Treatment Effects.

    PubMed

    Floris, Patrick; McGillicuddy, Nicola; Albrecht, Simone; Morrissey, Brian; Kaisermayer, Christian; Lindeberg, Anna; Bones, Jonathan

    2017-09-19

    An untargeted LC-MS/MS platform was implemented for monitoring variations in CHO cell culture media upon exposure to high temperature short time (HTST) treatment, a commonly used viral clearance upstream strategy. Chemically defined (CD) and hydrolysate-supplemented media formulations were not visibly altered by the treatment. The absence of solute precipitation effects during media treatment and very modest shifts in pH values observed indicated sufficient compatibility of the formulations evaluated with the HTST-processing conditions. Unsupervised chemometric analysis of LC-MS/MS data, however, revealed clear separation of HTST-treated samples from untreated counterparts as observed from analysis of principal components and hierarchical clustering sample grouping. An increased presence of Maillard products in HTST-treated formulations contributed to the observed differences which included organic acids, observed particularly in chemically defined formulations, and furans, pyridines, pyrazines, and pyrrolidines which were determined in hydrolysate-supplemented formulations. The presence of Maillard products in media did not affect cell culture performance with similar growth and viability profiles observed for CHO-K1 and CHO-DP12 cells when cultured using both HTST-treated and untreated media formulations.

  9. Pediatric Reference Intervals for Free Thyroxine and Free Triiodothyronine

    PubMed Central

    Jang, Megan; Guo, Tiedong; Soldin, Steven J.

    2009-01-01

    Background The clinical value of free thyroxine (FT4) and free triiodothyronine (FT3) analysis depends on the reference intervals with which they are compared. We determined age- and sex-specific reference intervals for neonates, infants, and children 0–18 years of age for FT4 and FT3 using tandem mass spectrometry. Methods Reference intervals were calculated for serum FT4 (n = 1426) and FT3 (n = 1107) obtained from healthy children between January 1, 2008, and June 30, 2008, from Children's National Medical Center and Georgetown University Medical Center Bioanalytical Core Laboratory, Washington, DC. Serum samples were analyzed using isotope dilution liquid chromatography tandem mass spectrometry (LC/MS/MS) with deuterium-labeled internal standards. Results FT4 reference intervals were very similar for males and females of all ages and ranged between 1.3 and 2.4 ng/dL for children 1 to 18 years old. FT4 reference intervals for 1- to 12-month-old infants were 1.3–2.8 ng/dL. These 2.5 to 97.5 percentile intervals were much tighter than reference intervals obtained using immunoassay platforms 0.48–2.78 ng/dL for males and 0.85–2.09 ng/dL for females. Similarly, FT3 intervals were consistent and similar for males and females and for all ages, ranging between 1.5 pg/mL and approximately 6.0 pg/mL for children 1 month of age to 18 years old. Conclusions This is the first study to provide pediatric reference intervals of FT4 and FT3 for children from birth to 18 years of age using LC/MS/MS. Analysis using LC/MS/MS provides more specific quantification of thyroid hormones. A comparison of the ultrafiltration tandem mass spectrometric method with equilibrium dialysis showed very good correlation. PMID:19583487

  10. Quantitative Determination of Perfluorochemicals and Fluorotelomer Alcohols in Plants from Biosolid-Amended Fields using LC/MS/MS and GC/MS

    EPA Science Inventory

    Analytical methods for determining perfluorochemicals (PFCs) and fluorotelomer alcohols (FTOHs) in plants using liquid chromatography/tandem mass spectrometry (LC/MS/MS) and gas chromatography/mass spectrometry (GC/MS) were developed, and applied to quantify a suite of analytes i...

  11. Determination of lipophilic toxins by LC/MS/MS: single-laboratory validation.

    PubMed

    Villar-González, Adriano; Rodríguez-Velasco, María Luisa; Gago-Martínez, Ana

    2011-01-01

    An LC/MS/MS method has been developed, assessed, and intralaboratory-validated for the analysis of the lipophilic toxins currently regulated by European Union legislation: okadaic acid (OA) and dinophysistoxins 1 and 2, including their ester forms; azaspiracids 1, 2, and 3; pectenotoxins 1 and 2; yessotoxin (YTX), and the analogs 45 OH-YTX, Homo YTX, and 45 OH-Homo YTX; as well as for the analysis of 13-desmetil-spirolide C. The method consists of duplicate sample extraction with methanol and direct analysis of the crude extract without further cleanup or concentration. Ester forms of OA and dinophysistoxins are detected as the parent ions after alkaline hydrolysis of the extract. The validation process of this method was performed using both fortified and naturally contaminated samples, and experiments were designed according to International Organization for Standardization, International Union of Pure and Applied Chemistry, and AOAC guidelines. With the exception of YTX in fortified samples, RSDr below 15% and RSDR were below 25%. Recovery values were between 77 and 95%, and LOQs were below 60 microg/kg. These data together with validation experiments for recovery, selectivity, robustness, traceability, and linearity, as well as uncertainty calculations, are presented in this paper.

  12. Liquid Chromatography Electrospray Ionization Mass Spectrometric (LC-ESI-MS) and Desorption Electrospray Ionization Mass Spectrometric (DESI-MS) Identification of Chemical Warfare Agents in Consumer Products

    DTIC Science & Technology

    2007-06-01

    T ACanadaY Approved for PublicR Distribution Uln& Liquid Chromatography Electrospray Ionization Mass Spectrometric ( LC -ESI- MS) and Desorption...consumer products with chemical warfare agents or other toxic chemicals. Liquid chromatography electrospray ionization mass spectrometry ( LC -ESI-MS) and...house LC -ESI-MS and LC -ESI-MS/MS methods were evaluated for the determination of chemical warfare agents in spiked bottled water samples. The

  13. mzDB: A File Format Using Multiple Indexing Strategies for the Efficient Analysis of Large LC-MS/MS and SWATH-MS Data Sets*

    PubMed Central

    Bouyssié, David; Dubois, Marc; Nasso, Sara; Gonzalez de Peredo, Anne; Burlet-Schiltz, Odile; Aebersold, Ruedi; Monsarrat, Bernard

    2015-01-01

    The analysis and management of MS data, especially those generated by data independent MS acquisition, exemplified by SWATH-MS, pose significant challenges for proteomics bioinformatics. The large size and vast amount of information inherent to these data sets need to be properly structured to enable an efficient and straightforward extraction of the signals used to identify specific target peptides. Standard XML based formats are not well suited to large MS data files, for example, those generated by SWATH-MS, and compromise high-throughput data processing and storing. We developed mzDB, an efficient file format for large MS data sets. It relies on the SQLite software library and consists of a standardized and portable server-less single-file database. An optimized 3D indexing approach is adopted, where the LC-MS coordinates (retention time and m/z), along with the precursor m/z for SWATH-MS data, are used to query the database for data extraction. In comparison with XML formats, mzDB saves ∼25% of storage space and improves access times by a factor of twofold up to even 2000-fold, depending on the particular data access. Similarly, mzDB shows also slightly to significantly lower access times in comparison with other formats like mz5. Both C++ and Java implementations, converting raw or XML formats to mzDB and providing access methods, will be released under permissive license. mzDB can be easily accessed by the SQLite C library and its drivers for all major languages, and browsed with existing dedicated GUIs. The mzDB described here can boost existing mass spectrometry data analysis pipelines, offering unprecedented performance in terms of efficiency, portability, compactness, and flexibility. PMID:25505153

  14. Dried haematic microsamples and LC-MS/MS for the analysis of natural and synthetic cannabinoids.

    PubMed

    Protti, Michele; Rudge, James; Sberna, Angelo Eliseo; Gerra, Gilberto; Mercolini, Laura

    2017-02-15

    Synthetic cannabinoids are new psychoactive substances (NPS) with similar effects when compared to natural ones found in Cannabis derivatives. They have rapidly integrated into the illicit market, often sold as alternatives under international control. The need to identify and quantify an unprecedented and growing number of new compounds represents a unique challenge for toxicological, forensic and anti-doping analysis. Dried blood spots have been used within the bioanalytical framework in place of plasma or serum, in order to reduce invasiveness, lower sample size, simplify handling, storage and shipping of samples and to facilitate home-based and on-field applications. However, DBS implementation has been limited mainly by concerns related to haematocrit effect on method accuracy. Volumetric absorptive microsampling (VAMS™), a second generation dried miniaturized sampling technology, has been developed just in order to eliminate haematocrit effect, thus providing accurate sampling but still granting feasible sample processing. An original LC-MS/MS method was herein developed and validated for the analysis of THC and its 2 main metabolites, together with 10 representative synthetic cannabinoids in both DBS and VAMS dried microsamples. The ultimate goal of this work is to provide highly innovative DBS and VAMS analytical protocols, whose performances were extensively optimized and compared, in order to provide effective and alternative tools that can be applied for natural and synthetic cannabinoid determination, in place of classical analytical strategies. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Multiclass determination and confirmation of antibiotic residues in honey using LC-MS/MS.

    PubMed

    Lopez, Mayda I; Pettis, Jeffery S; Smith, I Barton; Chu, Pak-Sin

    2008-03-12

    A multiclass method has been developed for the determination and confirmation in honey of tetracyclines (chlortetracycline, doxycycline, oxytetracycline, and tetracycline), fluoroquinolones (ciprofloxacin, danofloxacin, difloxacin, enrofloxacin, and sarafloxacin), macrolides (tylosin), lincosamides (lincomycin), aminoglycosides (streptomycin), sulfonamides (sulfathiazole), phenicols (chloramphenicol), and fumagillin residues using liquid chromatography tandem mass spectrometry (LC-MS/MS). Erythromycin (a macrolide) and monensin (an ionophore) can be detected and confirmed but not quantitated. Honey samples (approximately 2 g) are dissolved in 10 mL of water and centrifuged. An aliquot of the supernatant is used to determine streptomycin. The remaining supernatant is filtered through a fine-mesh nylon fabric and cleaned up by solid phase extraction. After solvent evaporation and sample reconstitution, 15 antibiotics are assayed by LC-MS/MS using electrospray ionization (ESI) in positive ion mode. Afterward, chloramphenicol is assayed using ESI in negative ion mode. The method has been validated at the low part per billion levels for most of the drugs with accuracies between 65 and 104% and coefficients of variation less than 17%. The evaluation of matrix effects caused by honey of different floral origin is presented.

  16. Tracking emerging mycotoxins in food: development of an LC-MS/MS method for free and modified Alternaria toxins.

    PubMed

    Puntscher, Hannes; Kütt, Mary-Liis; Skrinjar, Philipp; Mikula, Hannes; Podlech, Joachim; Fröhlich, Johannes; Marko, Doris; Warth, Benedikt

    2018-05-16

    Mycotoxins produced by Alternaria fungi are ubiquitous food contaminants, but analytical methods for generating comprehensive exposure data are rare. We describe the development of an LC-MS/MS method covering 17 toxins for investigating the natural occurrence of free and modified Alternaria toxins in tomato sauce, sunflower seed oil, and wheat flour. Target analytes included alternariol (AOH), AOH-3-glucoside, AOH-9-glucoside, AOH-3-sulfate, alternariol monomethyl ether (AME), AME-3-glucoside, AME-3-sulfate, altenuene, isoaltenuene, tenuazonic acid (TeA), tentoxin (TEN), altertoxin I and II, alterperylenol, stemphyltoxin III, altenusin, and altenuic acid III. Extensive optimization resulted in a time- and cost-effective sample preparation protocol and a chromatographic baseline separation of included isomers. Overall, adequate limits of detection (0.03-9 ng/g) and quantitation (0.6-18 ng/g), intermediate precision (9-44%), and relative recovery values (75-100%) were achieved. However, stemphyltoxin III, AOH-3-sulfate, AME-3-sulfate, altenusin, and altenuic acid III showed recoveries in wheat flour below 70%, while their performance was stable and reproducible. Our pilot study with samples from the Austrian retail market demonstrated that tomato sauces (n = 12) contained AOH, AME, TeA, and TEN in concentrations up to 20, 4, 322, and 0.6 ng/g, while sunflower seed oil (n = 7) and wheat flour samples (n = 9) were contaminated at comparatively lower levels. Interestingly and of relevance for risk assessment, AOH-9-glucoside, discovered for the first time in naturally contaminated food items, and AME-3-sulfate were found in concentrations similar to their parent toxins. In conclusion, the established multi-analyte method proved to be fit for purpose for generating comprehensive Alternaria toxin occurrence data in different food matrices. Graphical abstract ᅟ.

  17. On-line capillary electrophoresis/laser-induced fluorescence/mass spectrometry analysis of glycans labeled with Teal™ fluorescent dye using an electrokinetic sheath liquid pump-based nanospray ion source.

    PubMed

    Khan, Shaheer; Liu, Jenkuei; Szabo, Zoltan; Kunnummal, Baburaj; Han, Xiaorui; Ouyang, Yilan; Linhardt, Robert J; Xia, Qiangwei

    2018-06-15

    N-linked glycan analysis of recombinant therapeutic proteins, such as monoclonal antibodies, Fc-fusion proteins, and antibody-drug conjugates, provides valuable information regarding protein therapeutics glycosylation profile. Both qualitative identification and quantitative analysis of N-linked glycans on recombinant therapeutic proteins are critical analytical tasks in the biopharma industry during the development of a biotherapeutic. Currently, such analyses are mainly carried out using capillary electrophoresis/laser-induced fluorescence (CE/LIF), liquid chromatography/fluorescence (LC/FLR), and liquid chromatography/fluorescence/mass spectrometry (LC/FLR/MS) technologies. N-linked glycans are first released from glycoproteins by enzymatic digestion, then labeled with fluorescence dyes for subsequent CE or LC separation, and LIF or MS detection. Here we present an on-line CE/LIF/MS N-glycan analysis workflow that incorporates the fluorescent Teal™ dye and an electrokinetic pump-based nanospray sheath liquid capillary electrophoresis/mass spectrometry (CE/MS) ion source. Electrophoresis running buffer systems using ammonium acetate and ammonium hydroxide were developed for the negative ion mode CE/MS analysis of fluorescence-labeled N-linked glycans. Results show that on-line CE/LIF/MS analysis can be readily achieved using this versatile CE/MS ion source on common CE/MS instrument platforms. This on-line CE/LIF/MS method using Teal™ fluorescent dye and electrokinetic pump-based nanospray sheath liquid CE/MS coupling technology holds promise for on-line quantitation and identification of N-linked glycans on recombinant therapeutic proteins. Copyright © 2018 John Wiley & Sons, Ltd.

  18. Automated metal-free multiple-column nanoLC for improved phosphopeptide analysis sensitivity and throughput

    PubMed Central

    Zhao, Rui; Ding, Shi-Jian; Shen, Yufeng; Camp, David G.; Livesay, Eric A.; Udseth, Harold; Smith, Richard D.

    2009-01-01

    We report on the development and characterization of automated metal-free multiple-column nanoLC instrumentation for sensitive and high-throughput analysis of phosphopeptides with mass spectrometry analysis. The system implements a multiple-column capillary LC fluidic design developed for high-throughput analysis of peptides (Anal. Chem. 2001, 73, 3011–3021), incorporating modifications to achieve broad and sensitive analysis of phosphopeptides. The integrated nanoLC columns (50 µm i.d. × 30 cm containing 5 µm C18 particles) and the on-line solid phase extraction columns (150 µm i.d. × 4 cm containing 5 µm C18 particles) were connected to automatic switching valves with non-metal chromatographic accessories, and other modifications to avoid the exposure of the analyte to any metal surfaces during handling, separation, and electrospray ionization. The nanoLC developed provided a separation peak capacity of ∼250 for phosphopeptides (and ∼400 for normal peptides). A detection limit of 0.4 fmol was obtained when a linear ion trap tandem mass spectrometer (Finnegan LTQ) was coupled to a 50-µm i.d. column of the nanoLC. The separation power and sensitivity provided by the nanoLC-LTQ enabled identification of ∼4600 phosphopeptide candidates from ∼60 µg COS-7 cell tryptic digest followed by IMAC enrichment and ∼520 tyrosine phosphopeptides from ∼2 mg of human T cells digests followed by phosphotyrosine peptide immunoprecipitation. PMID:19217835

  19. Label-free DNA hybridization detection and single base-mismatch discrimination using CE-ICP-MS assay.

    PubMed

    Li, Yan; Sun, Shao-kai; Yang, Jia-lin; Jiang, Yan

    2011-12-07

    Detecting a specific DNA sequence and discriminating single base-mismatch is critical to clinical diagnosis, paternity testing, forensic sciences, food and drug industry, pathology, genetics, environmental monitoring, and anti-bioterrorism. To this end, capillary electrophoresis (CE) coupled with the inductively coupled plasma mass spectrometry (ICP-MS) method is developed using the displacing interaction between the target ssDNA and the competitor Hg(2+) for the first time. The thymine-rich capture ssDNA 1 is interacted with the competitor Hg(2+), forming an assembled complex in a hairpin-structure between the thymine bases arrangement at both sides of the capture ssDNA 1. In the presence of a target ssDNA with stronger affinity than that of the competitor Hg(2+), the energetically favorable hybridization between capture ssDNA 1 and the target ssDNA destroys the hairpin-structure and releases the competitor as free Hg(2+), which was then read out and accurately quantified by CE-ICP-MS assay. Under the optimal CE separation conditions, free Hg(2+) ions and its capture ssDNA 1 adduct were baseline separated and detected on-line by ICP-MS; the increased peak intensity of free Hg(2+) against the concentration of perfectly complementary target ssDNA was linear over the concentration range of 30-600 nmol L(-1) with a limit of detection of 8 nmol L(-1) (3s, n = 11) in the pre-incubated mixture containing 1 μmol L(-1) Hg(2+) and 0.2 μmol L(-1) capture ssDNA 1. This new assay method is simple in design since any target ssDNA binding can in principle result in free Hg(2+) release by 6-fold Hg(2+) signal amplification, avoiding oligonucleotide labeling or assistance by excess signal transducer and signal reporter to read out the target. Due to element-specific detection of ICP-MS in our assay procedure, the interference from the autofluorescence of substrata was eliminated.

  20. S100A8 as potential salivary biomarker of oral squamous cell carcinoma using nanoLC-MS/MS.

    PubMed

    Jou, Yu-Jen; Hua, Chun-Hung; Lin, Chia-Der; Lai, Chih-Ho; Huang, Su-Hua; Tsai, Ming-Hsui; Kao, Jung-Yie; Lin, Cheng-Wen

    2014-09-25

    Oral squamous cell carcinoma (OSCC) shows low 5-year survival; early treatment greatly reduces mortality and morbidity. Saliva is a non-invasive sample, with good potential to discover biomarkers for early detection. NanoLC-MS/MS served to analyze saliva proteome from control subjects (n=35) and OSCC patients T1 (n=29), T2 (n=36), T3 (n=14) and T4 (n=21) stages. Identified biomarkers were verified by Western blot and ELISA assays. NanoLC-MS/MS analysis of salivary proteins between 10 and 15kDa identified S100A8, hemoglobin delta and gamma-G globin in T3 and T4 stage OSCC as well as S100A7 in T1 and T2 stage OSCC. Western blot and ELISA indicated positive correlation between salivary S100A8 increment and tumor size stage. High level of S100A8 appeared in 3.4, 13.9, 92.9, and 100% of saliva OSCC patients with T1, T2, T3, and T4 stages, respectively. Significant increase of salivary S100A7 was observed in 20.7% and 11.1% of those with T1 and T2, respectively. AUROC curve indicated high sensitivity, specificity and accuracy of S100A8-based ELISA as a detector. NanoLC-MS/MS, Western blot and ELISA manifested salivary S100A8 as a specific and sensitive marker for detection of OSCC patients. Salivary S100A8 protein could be applicable in developing OSCC diagnostics. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. A robust, sensitive assay for genomic uracil determination by LC/MS/MS reveals lower levels than previously reported.

    PubMed

    Galashevskaya, Anastasia; Sarno, Antonio; Vågbø, Cathrine B; Aas, Per A; Hagen, Lars; Slupphaug, Geir; Krokan, Hans E

    2013-09-01

    Considerable progress has been made in understanding the origins of genomic uracil and its role in genome stability and host defense; however, the main question concerning the basal level of uracil in DNA remains disputed. Results from assays designed to quantify genomic uracil vary by almost three orders of magnitude. To address the issues leading to this inconsistency, we explored possible shortcomings with existing methods and developed a sensitive LC/MS/MS-based method for the absolute quantification of genomic 2'-deoxyuridine (dUrd). To this end, DNA was enzymatically hydrolyzed to 2'-deoxyribonucleosides and dUrd was purified in a preparative HPLC step and analyzed by LC/MS/MS. The standard curve was linear over four orders of magnitude with a quantification limit of 5 fmol dUrd. Control samples demonstrated high inter-experimental accuracy (94.3%) and precision (CV 9.7%). An alternative method that employed UNG2 to excise uracil from DNA for LC/MS/MS analysis gave similar results, but the intra-assay variability was significantly greater. We quantified genomic dUrd in Ung(+/+) and Ung(-/-) mouse embryonic fibroblasts and human lymphoblastoid cell lines carrying UNG mutations. DNA-dUrd is 5-fold higher in Ung(-/-) than in Ung(+/+) fibroblasts and 11-fold higher in UNG2 dysfunctional than in UNG2 functional lymphoblastoid cells. We report approximately 400-600 dUrd per human or murine genome in repair-proficient cells, which is lower than results using other methods and suggests that genomic uracil levels may have previously been overestimated. Copyright © 2013 The Authors. Published by Elsevier B.V. All rights reserved.

  2. Determination of Dextromethorphan in Oral Fluid by LC-MS-MS.

    PubMed

    Amaratunga, Piyadarsha; Clothier, Morgan; Lorenz Lemberg, Bridget; Lemberg, Dave

    2016-06-01

    Dextromethorphan (DXM) is an antitussive drug found in commonly used nonprescription cold and cough medications. At low doses, DXM is a safe drug that does not produce adverse reactions. However, abuse of DXM has been reported among adolescents and young adults using the drug at higher doses. DXM is not a scheduled drug in the USA, and the primary reason for its abuse is the ease of availability. DXM is available to purchase in the form of over-the-counter cough medications, such as Robitussin(®) and Coricidin(®), or it can be purchased over the Internet in the form of a powder. In this research work, we developed an LC-MS-MS method that can quantify DXM and dextrorphan (DXO) in oral fluid in a high-throughput toxicology laboratory setting. The developed method was validated according to the Scientific Working Group for Forensic Toxicology guidelines. The linear dynamic range was 5-100 ng/mL with a lowest limit of quantitation (LLOQ) of 5.0 ng/mL for DXM and DXO. Overall, the results of the accuracy and the precision values were within the acceptance criteria for both drugs. In addition, selectivity, matrix effect and recovery were calculated for the LC-MS-MS method. Authentic samples (n = 59) were tested to evaluate the applicability of the method. Thirty samples were found to be positive for DXM and DXO and two samples were found to be positive for DXM only. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Efficiency gains in tracer identification for nuclear imaging: can in vivo LC-MS/MS evaluation of small molecules screen for successful PET tracers?

    PubMed

    Joshi, Elizabeth M; Need, Anne; Schaus, John; Chen, Zhaogen; Benesh, Dana; Mitch, Charles; Morton, Stuart; Raub, Thomas J; Phebus, Lee; Barth, Vanessa

    2014-12-17

    Positron emission tomography (PET) imaging has become a useful noninvasive technique to explore molecular biology within living systems; however, the utility of this method is limited by the availability of suitable radiotracers to probe specific targets and disease biology. Methods to identify potential areas of improvement in the ability to predict small molecule performance as tracers prior to radiolabeling would speed the discovery of novel tracers. In this retrospective analysis, we characterized the brain penetration or peak SUV (standardized uptake value), binding potential (BP), and brain exposure kinetics across a series of known, nonradiolabeled PET ligands using in vivo LC-MS/MS (liquid chromatography coupled to mass spectrometry) and correlated these parameters with the reported PET ligand performance in nonhuman primates and humans available in the literature. The PET tracers studied included those reported to label G protein-coupled receptors (GPCRs), intracellular enzymes, and transporters. Additionally, data for each tracer was obtained from a mouse brain uptake assay (MBUA), previously published, where blood-brain barrier (BBB) penetration and clearance parameters were assessed and compared against similar data collected on a broad compound set of central nervous system (CNS) therapeutic compounds. The BP and SUV identified via nonradiolabeled LC-MS/MS, while different from the published values observed in the literature PET tracer data, allowed for an identification of initial criteria values we sought to facilitate increased potential for success from our early discovery screening paradigm. Our analysis showed that successful, as well as novel, clinical PET tracers exhibited BP of greater than 1.5 and peak SUVs greater than approximately 150% at 5 min post dose in rodents. The brain kinetics appeared similar between both techniques despite differences in tracer dose, suggesting linearity across these dose ranges. The assessment of tracers in a

  4. Developments in label-free microfluidic methods for single-cell analysis and sorting.

    PubMed

    Carey, Thomas R; Cotner, Kristen L; Li, Brian; Sohn, Lydia L

    2018-04-24

    Advancements in microfluidic technologies have led to the development of many new tools for both the characterization and sorting of single cells without the need for exogenous labels. Label-free microfluidics reduce the preparation time, reagents needed, and cost of conventional methods based on fluorescent or magnetic labels. Furthermore, these devices enable analysis of cell properties such as mechanical phenotype and dielectric parameters that cannot be characterized with traditional labels. Some of the most promising technologies for current and future development toward label-free, single-cell analysis and sorting include electronic sensors such as Coulter counters and electrical impedance cytometry; deformation analysis using optical traps and deformation cytometry; hydrodynamic sorting such as deterministic lateral displacement, inertial focusing, and microvortex trapping; and acoustic sorting using traveling or standing surface acoustic waves. These label-free microfluidic methods have been used to screen, sort, and analyze cells for a wide range of biomedical and clinical applications, including cell cycle monitoring, rapid complete blood counts, cancer diagnosis, metastatic progression monitoring, HIV and parasite detection, circulating tumor cell isolation, and point-of-care diagnostics. Because of the versatility of label-free methods for characterization and sorting, the low-cost nature of microfluidics, and the rapid prototyping capabilities of modern microfabrication, we expect this class of technology to continue to be an area of high research interest going forward. New developments in this field will contribute to the ongoing paradigm shift in cell analysis and sorting technologies toward label-free microfluidic devices, enabling new capabilities in biomedical research tools as well as clinical diagnostics. This article is categorized under: Diagnostic Tools > Biosensing Diagnostic Tools > Diagnostic Nanodevices. © 2018 Wiley Periodicals, Inc.

  5. Analysis of Intrinsic Peptide Detectability via Integrated Label-Free and SRM-Based Absolute Quantitative Proteomics.

    PubMed

    Jarnuczak, Andrew F; Lee, Dave C H; Lawless, Craig; Holman, Stephen W; Eyers, Claire E; Hubbard, Simon J

    2016-09-02

    Quantitative mass spectrometry-based proteomics of complex biological samples remains challenging in part due to the variability and charge competition arising during electrospray ionization (ESI) of peptides and the subsequent transfer and detection of ions. These issues preclude direct quantification from signal intensity alone in the absence of a standard. A deeper understanding of the governing principles of peptide ionization and exploitation of the inherent ionization and detection parameters of individual peptides is thus of great value. Here, using the yeast proteome as a model system, we establish the concept of peptide F-factor as a measure of detectability, closely related to ionization efficiency. F-factor is calculated by normalizing peptide precursor ion intensity by absolute abundance of the parent protein. We investigated F-factor characteristics in different shotgun proteomics experiments, including across multiple ESI-based LC-MS platforms. We show that F-factors mirror previously observed physicochemical predictors as peptide detectability but demonstrate a nonlinear relationship between hydrophobicity and peptide detectability. Similarly, we use F-factors to show how peptide ion coelution adversely affects detectability and ionization. We suggest that F-factors have great utility for understanding peptide detectability and gas-phase ion chemistry in complex peptide mixtures, selection of surrogate peptides in targeted MS studies, and for calibration of peptide ion signal in label-free workflows. Data are available via ProteomeXchange with identifier PXD003472.

  6. Analytical and clinical performance of the new Fujirebio 25-OH vitamin D assay, a comparison with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and three other automated assays.

    PubMed

    Saleh, Lanja; Mueller, Daniel; von Eckardstein, Arnold

    2016-04-01

    We evaluated the analytical and clinical performance of the new Lumipulse® G 25-OH vitamin D assay from Fujirebio, and compared it to a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method and three other commercial automated assays. Total 25 hydroxy vitamin D (25(OH)D) levels were measured in 100 selected serum samples from our routine analysis with Fujirebio 25(OH)D assay. The results were compared with those obtained with LC-MS/MS and three other automated 25(OH)D assays (Abbott, Beckman, and Roche). The accuracy of each assay tested was evaluated against a Labquality reference serum panel for 25(OH)D (Ref!25OHD; University of Ghent). Intra- and inter-day imprecision of the Fujirebio 25(OH)D assay was <5%. Fujirebio 25(OH)D assay showed the highest correlation among the assays tested with the LC-MS/MS method (R=0.986). The mean relative bias obtained was -15.6% (Fujirebio), -12.7% (Beckman), -2.1% (Abbott) and 9.7% (Roche) as compared to LC-MS/MS. Comparison with the Labquality certified reference serum panel yielded a mean bias of -11.8% (Fujirebio), -14.1% (Beckman), 4.4% (Abbott) and 3.2% (Roche), respectively. Compared to LC-MS/MS, the sensitivity of different methods in detecting vitamin D insufficiency (<50 nmol/L) varied from 100% for the Fujirebio assay to 72.7% for Roche, and specificity ranged from 94.4% for Roche to 87.6% for Beckman. The Lumipulse G 25-OH vitamin D assay from Fujirebio demonstrated a good correlation with LC-MS/MS and some immunoassays. The performance of the assay is well-suited for routine 25(OH)D measurement in clinical serum samples. A correction for the observed negative bias vs. LC-MS/MS could be considered.

  7. Qualitative metabolome analysis of human cerebrospinal fluid by 13C-/12C-isotope dansylation labeling combined with liquid chromatography Fourier transform ion cyclotron resonance mass spectrometry.

    PubMed

    Guo, Kevin; Bamforth, Fiona; Li, Liang

    2011-02-01

    Metabolome analysis of human cerebrospinal fluid (CSF) is challenging because of low abundance of metabolites present in a small volume of sample. We describe and apply a sensitive isotope labeling LC-MS technique for qualitative analysis of the CSF metabolome. After a CSF sample is divided into two aliquots, they are labeled by (13)C-dansyl and (12)C-dansyl chloride, respectively. The differentially labeled aliquots are then mixed and subjected to LC-MS using Fourier-transform ion cyclotron resonance mass spectrometry (FTICR MS). Dansylation offers significant improvement in the performance of chromatography separation and detection sensitivity. Moreover, peaks detected in the mass spectra can be readily analyzed for ion pair recognition and database search based on accurate mass and/or retention time information. It is shown that about 14,000 features can be detected in a 25-min LC-FTICR MS run of a dansyl-labeled CSF sample, from which about 500 metabolites can be profiled. Results from four CSF samples are compared to gauge the detectability of metabolites by this method. About 261 metabolites are commonly detected in replicate runs of four samples. In total, 1132 unique metabolite ion pairs are detected and 347 pairs (31%) matched with at least one metabolite in the Human Metabolome Database. We also report a dansylation library of 220 standard compounds and, using this library, about 85 metabolites can be positively identified. Among them, 21 metabolites have never been reported to be associated with CSF. These results illustrate that the dansylation LC-FTICR MS method can be used to analyze the CSF metabolome in a more comprehensive manner. © American Society for Mass Spectrometry, 2011

  8. Qualitative Metabolome Analysis of Human Cerebrospinal Fluid by 13C-/12C-Isotope Dansylation Labeling Combined with Liquid Chromatography Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Guo, Kevin; Bamforth, Fiona; Li, Liang

    2011-02-01

    Metabolome analysis of human cerebrospinal fluid (CSF) is challenging because of low abundance of metabolites present in a small volume of sample. We describe and apply a sensitive isotope labeling LC-MS technique for qualitative analysis of the CSF metabolome. After a CSF sample is divided into two aliquots, they are labeled by 13C-dansyl and 12C-dansyl chloride, respectively. The differentially labeled aliquots are then mixed and subjected to LC-MS using Fourier-transform ion cyclotron resonance mass spectrometry (FTICR MS). Dansylation offers significant improvement in the performance of chromatography separation and detection sensitivity. Moreover, peaks detected in the mass spectra can be readily analyzed for ion pair recognition and database search based on accurate mass and/or retention time information. It is shown that about 14,000 features can be detected in a 25-min LC-FTICR MS run of a dansyl-labeled CSF sample, from which about 500 metabolites can be profiled. Results from four CSF samples are compared to gauge the detectability of metabolites by this method. About 261 metabolites are commonly detected in replicate runs of four samples. In total, 1132 unique metabolite ion pairs are detected and 347 pairs (31%) matched with at least one metabolite in the Human Metabolome Database. We also report a dansylation library of 220 standard compounds and, using this library, about 85 metabolites can be positively identified. Among them, 21 metabolites have never been reported to be associated with CSF. These results illustrate that the dansylation LC-FTICR MS method can be used to analyze the CSF metabolome in a more comprehensive manner.

  9. Clinical laboratory verification of thyroglobulin concentrations in the presence of autoantibodies to thyroglobulin: comparison of EIA, radioimmunoassay and LC MS/MS measurements in an Urban Hospital.

    PubMed

    Wheeler, Sarah E; Liu, Li; Blair, Harry C; Sivak, Richard; Longo, Nancy; Tischler, Jeffery; Mulvey, Kathryn; Palmer, Octavia M Peck

    2017-12-08

    Thyroglobulin (Tg) measurements assess recurrence in post-thyroidectomy thyroid cancer patients. Tg measurements by enzyme immunoassays (EIA) can be falsely elevated by interference from Tg autoantibodies (TgAb). Radioimmunoassay (RIA) is less susceptible to TgAb interference and has been the standard-of-care test for TgAb positive patients. Recently developed liquid chromatography tandem mass spectrometry (LC-MS/MS) methods may eliminate TgAb interference. We assessed the performance of Tg measurements by EIA, RIA and LC-MS/MS to evaluate TgAb interference differences. We measured TgAb and Tg in 50 plasma samples from 40 patients in whom Tg measurement was part of their routine follow-up and 10 healthy volunteers. Discrepancy between EIA and both LC-MS/MS and RIA was observed at low Tg concentrations (≤ 7.55 ng/mL) in TgAb positive specimens (LC-MS/MS = 1.9 * EIA - 0.03, r = 0.68). RIA and LC-MS/MS Tg measurements in TgAb positive specimens with low Tg concentrations had improved correlation but demonstrated bias (LC MS/MS = 0.6 * RIA - 1.4, r = 0.90). Disagreement between methods may be attributed to LC-MS/MS reported Tg concentrations as undetectable compared to RIA. It seems likely that most discrepant cases are falsely elevated in RIA due to TgAb interference, however, some cases appear below the detection limit of LC-MS/MS; implementation of LC-MS/MS by clinicians will require lower detection limits.

  10. LC/MS/MS Bioanalysis of Protein-Drug Conjugates-The Importance of Incorporating Succinimide Hydrolysis Products.

    PubMed

    Shi, Chuan; Goldberg, Shalom; Lin, Tricia; Dudkin, Vadim; Widdison, Wayne; Harris, Luke; Wilhelm, Sharon; Jmeian, Yazen; Davis, Darryl; O'Neil, Karyn; Weng, Naidong; Jian, Wenying

    2018-04-17

    Bioanalysis of antibody-drug conjugates (ADCs) is challenging due to the complex, heterogeneous nature of their structures and their complicated catabolism. To fully describe the pharmacokinetics (PK) of an ADC, several analytes are commonly quantified, including total antibody, conjugate, and payload. Among them, conjugate is the most challenging to measure, because it requires detection of both small and large molecules as one entity. Existing approaches to quantify the conjugated species of ADCs involve a ligand binding assay (LBA) for conjugated antibody or hybrid LBA/liquid chromatography/tandem mass spectrometry (LC/MS/MS) for quantitation of conjugated drug. In our current work for a protein-drug conjugate (PDC) using the Centyrin scaffold, a similar concept to ADCs but with smaller protein size, an alternative method to quantify the conjugate by using a surrogate peptide approach, was utilized. The His-tagged proteins were isolated from biological samples using immobilized metal affinity chromatography (IMAC), followed by trypsin digestion. The tryptic peptide containing the linker attached to the payload was used as a surrogate of the conjugate and monitored by LC/MS/MS analysis. During method development and its application, we found that hydrolysis of the succinimide ring of the linker was ubiquitous, taking place at many stages during the lifetime of the PDC including in the initial drug product, in vivo in circulation in the animals, and ex vivo during the trypsin digestion step of the sample preparation. We have shown that hydrolysis during trypsin digestion is concentration-independent and consistent during the work flow-therefore, having no impact on assay performance. However, for samples that have undergone extensive hydrolysis prior to trypsin digestion, significant bias could be introduced if only the non-hydrolyzed form is considered in the quantitation. Therefore, it is important to incorporate succinimide hydrolysis products in the

  11. MassCascade: Visual Programming for LC-MS Data Processing in Metabolomics.

    PubMed

    Beisken, Stephan; Earll, Mark; Portwood, David; Seymour, Mark; Steinbeck, Christoph

    2014-04-01

    Liquid chromatography coupled to mass spectrometry (LC-MS) is commonly applied to investigate the small molecule complement of organisms. Several software tools are typically joined in custom pipelines to semi-automatically process and analyse the resulting data. General workflow environments like the Konstanz Information Miner (KNIME) offer the potential of an all-in-one solution to process LC-MS data by allowing easy integration of different tools and scripts. We describe MassCascade and its workflow plug-in for processing LC-MS data. The Java library integrates frequently used algorithms in a modular fashion, thus enabling it to serve as back-end for graphical front-ends. The functions available in MassCascade have been encapsulated in a plug-in for the workflow environment KNIME, allowing combined use with e.g. statistical workflow nodes from other providers and making the tool intuitive to use without knowledge of programming. The design of the software guarantees a high level of modularity where processing functions can be quickly replaced or concatenated. MassCascade is an open-source library for LC-MS data processing in metabolomics. It embraces the concept of visual programming through its KNIME plug-in, simplifying the process of building complex workflows. The library was validated using open data.

  12. A flexible statistical model for alignment of label-free proteomics data--incorporating ion mobility and product ion information.

    PubMed

    Benjamin, Ashlee M; Thompson, J Will; Soderblom, Erik J; Geromanos, Scott J; Henao, Ricardo; Kraus, Virginia B; Moseley, M Arthur; Lucas, Joseph E

    2013-12-16

    The goal of many proteomics experiments is to determine the abundance of proteins in biological samples, and the variation thereof in various physiological conditions. High-throughput quantitative proteomics, specifically label-free LC-MS/MS, allows rapid measurement of thousands of proteins, enabling large-scale studies of various biological systems. Prior to analyzing these information-rich datasets, raw data must undergo several computational processing steps. We present a method to address one of the essential steps in proteomics data processing--the matching of peptide measurements across samples. We describe a novel method for label-free proteomics data alignment with the ability to incorporate previously unused aspects of the data, particularly ion mobility drift times and product ion information. We compare the results of our alignment method to PEPPeR and OpenMS, and compare alignment accuracy achieved by different versions of our method utilizing various data characteristics. Our method results in increased match recall rates and similar or improved mismatch rates compared to PEPPeR and OpenMS feature-based alignment. We also show that the inclusion of drift time and product ion information results in higher recall rates and more confident matches, without increases in error rates. Based on the results presented here, we argue that the incorporation of ion mobility drift time and product ion information are worthy pursuits. Alignment methods should be flexible enough to utilize all available data, particularly with recent advancements in experimental separation methods.

  13. Online extraction LC-MS/MS method for the simultaneous quantitative confirmation of urine drugs of abuse and metabolites: amphetamines, opiates, cocaine, cannabis, benzodiazepines and methadone.

    PubMed

    de Jager, Andrew D; Bailey, Neville L

    2011-09-01

    A rapid LC-MS/MS method for confirmatory testing of five major categories of drugs of abuse (amphetamine-type substances, opiates, cocaine, cannabis metabolites and benzodiazepines) in urine has been developed. All drugs of abuse mandated by the Australian/New Zealand Standard AS/NZS 4308:2008 are quantified in a single chromatographic run. Urine samples are diluted with a mixture of isotope labelled internal standards. An on-line trap-and-flush approach, followed by LC-ESI-MS/MS has been successfully used to process samples in a functioning drugs of abuse laboratory. Following injection of diluted urine samples, compounds retained on the trap cartridge are flushed onto a reverse-phase C18 HPLC column (5-μm particle size) with embedded hydrophylic functionality. A total chromatographic run-time of 15 min is required for adequate resolution. Automated quantitation software algorithms have been developed in-house using XML scripting to partially automate the identification of positive samples, taking into account ion ratio (IR) and retention times (Rt). The sensitivity of the assay was found to be adequate for the quantitation of drugs in urine at and below the confirmation cut-off concentrations prescribed by AS/NZS 4308:2008. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Combined LC/MS-platform for analysis of all major stratum corneum lipids, and the profiling of skin substitutes.

    PubMed

    van Smeden, Jeroen; Boiten, Walter A; Hankemeier, Thomas; Rissmann, Robert; Bouwstra, Joke A; Vreeken, Rob J

    2014-01-01

    Ceramides (CERs), cholesterol, and free fatty acids (FFAs) are the main lipid classes in human stratum corneum (SC, outermost skin layer), but no studies report on the detailed analysis of these classes in a single platform. The primary aims of this study were to 1) develop an LC/MS method for (semi-)quantitative analysis of all main lipid classes present in human SC; and 2) use this method to study in detail the lipid profiles of human skin substitutes and compare them to human SC lipids. By applying two injections of 10μl, the developed method detects all major SC lipids using RPLC and negative ion mode APCI-MS for detection of FFAs, and NPLC using positive ion mode APCI-MS to analyze CERs and cholesterol. Validation showed this lipid platform to be robust, reproducible, sensitive, and fast. The method was successfully applied on ex vivo human SC, human SC obtained from tape strips and human skin substitutes (porcine SC and human skin equivalents). In conjunction with FFA profiles, clear differences in CER profiles were observed between these different SC sources. Human skin equivalents more closely mimic the lipid composition of human stratum corneum than porcine skin does, although noticeable differences are still present. These differences gave biologically relevant information on some of the enzymes that are probably involved in SC lipid processing. For future research, this provides an excellent method for (semi-)quantitative, 'high-throughput' profiling of SC lipids and can be used to advance the understanding of skin lipids and the biological processes involved. © 2013.

  15. Investigating the adduct formation of organic mercury species with carbonic anhydrase and hemoglobin from human red blood cell hemolysate by means of LC/ESI-TOF-MS and LC/ICP-MS.

    PubMed

    Hogeback, Jens; Schwarzer, Miriam; Wehe, Christoph A; Sperling, Michael; Karst, Uwe

    2016-01-01

    The interaction of mercury species with human erythrocytes is studied to investigate possible high molecular binding partners for mercury species. Human blood hemolysate was spiked with methylmercury and investigated by means of liquid chromatography (LC) coupled to electrospray ionization time of flight mass spectrometry (ESI-ToF-MS) and inductively coupled plasma mass spectrometry (ICP-MS). Beside adduct formation of mercury species with hemoglobin, the main compound of the erythrocytes, mercury binding to the enzyme carbonic anhydrase was revealed. Due to an enzymatic digest of the protein-mercury adduct, the binding site at the free thiol group of the protein was identified. These results indicate that carbonic anhydrase might play a role in mercury toxicity.

  16. Effect of environment and genotype on commercial maize hybrids using LC/MS-based metabolomics.

    PubMed

    Baniasadi, Hamid; Vlahakis, Chris; Hazebroek, Jan; Zhong, Cathy; Asiago, Vincent

    2014-02-12

    We recently applied gas chromatography coupled to time-of-flight mass spectrometry (GC/TOF-MS) and multivariate statistical analysis to measure biological variation of many metabolites due to environment and genotype in forage and grain samples collected from 50 genetically diverse nongenetically modified (non-GM) DuPont Pioneer commercial maize hybrids grown at six North American locations. In the present study, the metabolome coverage was extended using a core subset of these grain and forage samples employing ultra high pressure liquid chromatography (uHPLC) mass spectrometry (LC/MS). A total of 286 and 857 metabolites were detected in grain and forage samples, respectively, using LC/MS. Multivariate statistical analysis was utilized to compare and correlate the metabolite profiles. Environment had a greater effect on the metabolome than genetic background. The results of this study support and extend previously published insights into the environmental and genetic associated perturbations to the metabolome that are not associated with transgenic modification.

  17. Enantioselective analysis of chloramphenicol residues in honey samples by chiral LC-MS/MS and results of a honey survey.

    PubMed

    Rimkus, Gerhard G; Hoffmann, Dirk

    2017-06-01

    Chloramphenicol (CAP) is a broad-spectrum antibiotic used widely in both human and veterinary medication. Since 1994, CAP has not been authorised for use in food-producing animals in the European Union due to several adverse effects. A minimum required performance level (MRPL) of 0.3 µg kg - 1 was established in 2003. The CAP molecule contains two asymmetric centres, thus in total four para-CAP stereoisomers exist. Only the RR-CAP enantiomer is bioactive, having significant antimicrobial activity. For the first time a chiral LC-MS/MS method is reported to identify and quantify the four CAP enantiomers at residue levels in honey samples. The method was validated at two concentration levels. The decision limits (CCα) and detection capabilities (CCß) were well below 0.3 µg kg - 1 , with limits of quantification (LOQs) between 0.08 and 0.12 µg kg - 1 for all four enantiomers. The method provides a sensitive and reliable analysis of CAP enantiomers in honey, and proved its robustness during the daily routine analyses of numerous honey samples. In an internal honey survey, in total 40 honey samples from different geographical regions with identified CAP residues at or above the MRPL were reanalysed by chiral LC-MS/MS. In nine honey samples only the bioactive RR-CAP was detected as anticipated. However, in all other 31 honey samples the non-bioactive SS-CAP was also identified and quantified unambiguously. In 10 of these samples, mixtures of RR- and SS-CAP were analysed, and in 21 samples only the SS-CAP enantiomer, with concentrations up to 2.2 µg kg - 1 . Most of these samples are honeys from Ukraine and Eastern Europe. This is the first report of SS-CAP residues in food samples. The potential sources for these findings are discussed and the need of further systematic studies emphasised. It is recommended to examine in more depth the toxicological profile of the individual CAP stereoisomers.

  18. Quantitative determination of mycotoxins in urine by LC-MS/MS.

    PubMed

    Ahn, J; Kim, D; Kim, H; Jahng, K-Y

    2010-12-01

    Naturally occurring mycotoxins are responsible for a wide array of adverse health effects. The measurement of urinary mycotoxin levels is a useful means of assessing an individual's exposure, but the development of sensitive and accurate analytical methods for detecting mycotoxins and their metabolites in urine samples is challenging. Urinary mycotoxins are present in low pg ml⁻¹ concentrations, and the chromatographic identification of their metabolites can be obscured by other endogenous metabolites. We developed an analytical method focused on the selection of two appropriate multiple-reaction monitoring transition for unambiguous identification and quantification of carcinogenic aflatoxin M₁ (AFM₁), ochratoxin A (OTA) and fumonisin B₁, B₂ (FB₁, FB₂) in urine samples from a small volunteer group in a pilot study. AFM₁, OTA, FB₁ and FB₂ were concentrated selectively, interfering substances were removed using an immunoaffinity column (IAC), and mycotoxins were measured using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in combination with a stable-isotope standard-dilution assay (SIDA). The method was sensitive enough to measure mycotoxins and their metabolites at pg ml⁻¹ levels in urine. The combination of LC-MS/MS and SIDA was critical to distinguishing pseudo-OTα interference from genuine OTα. Twelve urine samples contained OTA ranging from 0.013 to 0.093 ng ml⁻¹ (mean = 0.031 ng ml⁻¹). AFM₁ were detected in one sample at a 0.002 ng ml⁻¹ level, while FB₁ and FB₂ were undetectable in all 12 samples. None of the samples in this pilot study contained a detectable level of OTα, despite the presence of OTA, and this may suggest the need for further epidemiological investigation of OTA exposure in the Korean population.

  19. Online structural elucidation of alkaloids and other constituents in crude extracts and cultured cells of Nandina domestica by combination of LC-MS/MS, LC-NMR, and LC-CD analyses.

    PubMed

    Iwasa, Kinuko; Takahashi, Teturo; Nishiyama, Yumi; Moriyasu, Masataka; Sugiura, Makiko; Takeuchi, Atsuko; Tode, Chisato; Tokuda, Harukuni; Takeda, Kazuyoshi

    2008-08-01

    The combination of NMR, MS, and CD data permitted the structural elucidation including the absolute configuration of the known alkaloids and unknown components in the extract matrix solution of Nandina domestica without isolation and sample purification prior to the coupling experiments. Unstable natural stereoisomers were identified by LC-NMR and LC-MS. Five known alkaloids, (S)-isoboldine, (S)-domesticine, (S)-nantenine, sinoacutine, and menispermine, were identified from N. domestica. O-Methylpallidine and (E, E)-, (E, Z)-, and (Z, Z)-terrestribisamide were also characterized for the first time from this plant. Known jatrorrhizine, palmatine, and berberine and unknown (R)-carnegine and (E, E)-, (E, Z)-, and (Z, Z)-terrestribisamide were identified in the callus of N. domestica.

  20. Quantitative analysis of core fucosylation of serum proteins in liver diseases by LC-MS-MRM.

    PubMed

    Ma, Junfeng; Sanda, Miloslav; Wei, Renhuizi; Zhang, Lihua; Goldman, Radoslav

    2018-02-07

    Aberrant core fucosylation of proteins has been linked to liver diseases. In this study, we carried out multiple reaction monitoring (MRM) quantification of core fucosylated N-glycopeptides of serum proteins partially deglycosylated by a combination of endoglycosidases (endoF1, endoF2, and endoF3). To minimize variability associated with the preparatory steps, the analysis was performed without enrichment of glycopeptides or fractionation of serum besides the nanoRP chromatography. Specifically, we quantified core fucosylation of 22 N-glycopeptides derived from 17 proteins together with protein abundance of these glycoproteins in a cohort of 45 participants (15 disease-free control, 15 fibrosis and 15 cirrhosis patients) using a multiplex nanoUPLC-MS-MRM workflow. We find increased core fucosylation of 5 glycopeptides at the stage of liver fibrosis (i.e., N630 of serotransferrin, N107 of alpha-1-antitrypsin, N253 of plasma protease C1 inhibitor, N397 of ceruloplasmin, and N86 of vitronectin), increase of additional 6 glycopeptides at the stage of cirrhosis (i.e., N138 and N762 of ceruloplasmin, N354 of clusterin, N187 of hemopexin, N71 of immunoglobulin J chain, and N127 of lumican), while the degree of core fucosylation of 10 glycopeptides did not change. Interestingly, although we observe an increase in the core fucosylation at N86 of vitronectin in liver fibrosis, core fucosylation decreases on the N169 glycopeptide of the same protein. Our results demonstrate that the changes in core fucosylation are protein and site specific during the progression of fibrotic liver disease and independent of the changes in the quantity of N-glycoproteins. It is expected that the fully optimized multiplex LC-MS-MRM assay of core fucosylated glycopeptides will be useful for the serologic assessment of the fibrosis of liver. We have quantified the difference in core fucosylation among three comparison groups (healthy control, fibrosis and cirrhosis patients) using a sensitive and

  1. Androgen profiling by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in healthy normal-weight ovulatory and anovulatory late adolescent and young women.

    PubMed

    Fanelli, Flaminia; Gambineri, Alessandra; Belluomo, Ilaria; Repaci, Andrea; Di Lallo, Valentina Diana; Di Dalmazi, Guido; Mezzullo, Marco; Prontera, Olga; Cuomo, Gaia; Zanotti, Laura; Paccapelo, Alexandro; Morselli-Labate, Antonio Maria; Pagotto, Uberto; Pasquali, Renato

    2013-07-01

    Physiological transient imbalance typical of adolescence needs to be distinguished from hyperandrogenism-related dysfunction. The accurate determination of circulating androgens is the best indicator of hyperandrogenism. However, reliable reference intervals for adolescent and young women are not available. The aim of the study was to define androgen reference intervals in young women and to analyze the impact of the menstrual phase and ovulation efficiency over the androgen profile as assessed by reliable liquid chromatography-tandem mass spectrometry (LC-MS/MS) technique. Female high school students aged 16-19 years were included in the study. The study was performed on reference subjects properly selected among an unbiased population. Normal-weight, drug and disease free, eumenorrheic females with no signs of hyperandrogenism were included. The steroid hormone profile was determined by a validated in-house LC-MS/MS method. A statistical estimation of overall and menstrual phase-specific reference intervals was performed. A subgroup of anovulatory females was identified based on progesterone circulating levels. The impact of ovulation efficiency over hormonal profile was analyzed. A total of 159 females satisfied healthy criteria. Androgen levels did not vary according to menstrual phase, but a significantly higher upper reference limit was found for T in the luteal phase compared to the follicular phase. Higher T and androstenedione levels were observed in anovulatory compared to ovulatory females, paralleled by higher LH and FSH and lower 17-hydroxyprogesterone and 17β-estradiol levels. This is the first study providing LC-MS/MS-based, menstrual phase-specific reference intervals for the circulating androgen profile in young females. We identified a subgroup of anovulatory healthy females characterized by androgen imbalance.

  2. Determination of chloramphenicol and zeranols in pig muscle by immunoaffinity column clean-up and LC-MS/MS analysis.

    PubMed

    Wang, Qing; Zhao, Hua; Xi, Cunxian; Wang, Guomin; Chen, Dongdong; Ding, Shijia

    2014-01-01

    An immunoaffinity column clean-up and LC-MS/MS method was successfully developed for simultaneous determination of chloramphenicol, zearalanone, α-zearalanol, β-zearalanol, zearalenone, α-zearalenol and β-zearalenol in pig muscle. The sample was extracted with diethyl ether after enzymatic digestion by β-glucuronidase/sulfatase. The extracted solution was evaporated to dryness and the residue was then dissolved in 1 ml of 50% acetonitrile solution. After filtration and dilution with phosphate buffer solution (PBS), the reconstituted solution was cleaned-up with an IAC-CZ immunoaffinity column and then analysed by HPLC-MS/MS. The established method were validated by linearity (r ≥ 0.9990), precision (RSD ≥ 2.9%), average recovery (74.5-105.0%) and limit of detection (0.04-0.10 μg kg(-1)). The developed method is rapid, reliable, sensitive, accurate and has good applicability for real samples.

  3. Subnanogram proteomics: Impact of LC column selection, MS instrumentation and data analysis strategy on proteome coverage for trace samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, Ying; Zhao, Rui; Piehowski, Paul D.

    One of the greatest challenges for mass spectrometry (MS)-based proteomics is the limited ability to analyze small samples. Here we investigate the relative contributions of liquid chromatography (LC), MS instrumentation and data analysis methods with the aim of improving proteome coverage for sample sizes ranging from 0.5 ng to 50 ng. We show that the LC separations utilizing 30-µm-i.d. columns increase signal intensity by >3-fold relative to those using 75-µm-i.d. columns, leading to 32% increase in peptide identifications. The Orbitrap Fusion Lumos mass spectrometer significantly boosted both sensitivity and sequencing speed relative to earlier generation Orbitraps (e.g., LTQ-Orbitrap), leading tomore » a ~3× increase in peptide identifications and 1.7× increase in identified protein groups for 2 ng tryptic digests of bacterial lysate. The Match Between Runs algorithm of open-source MaxQuant software further increased proteome coverage by ~ 95% for 0.5 ng samples and by ~42% for 2 ng samples. The present platform is capable of identifying >3000 protein groups from tryptic digestion of cell lysates equivalent to 50 HeLa cells and 100 THP-1 cells (~10 ng total proteins), respectively, and >950 proteins from subnanogram bacterial and archaeal cell lysates. The present ultrasensitive LC-MS platform is expected to enable deep proteome coverage for subnanogram samples, including single mammalian cells.« less

  4. The clinical impact of recent advances in LC-MS for cancer biomarker discovery and verification.

    PubMed

    Wang, Hui; Shi, Tujin; Qian, Wei-Jun; Liu, Tao; Kagan, Jacob; Srivastava, Sudhir; Smith, Richard D; Rodland, Karin D; Camp, David G

    2016-01-01

    Mass spectrometry (MS) -based proteomics has become an indispensable tool with broad applications in systems biology and biomedical research. With recent advances in liquid chromatography (LC) and MS instrumentation, LC-MS is making increasingly significant contributions to clinical applications, especially in the area of cancer biomarker discovery and verification. To overcome challenges associated with analyses of clinical samples (for example, a wide dynamic range of protein concentrations in bodily fluids and the need to perform high throughput and accurate quantification of candidate biomarker proteins), significant efforts have been devoted to improve the overall performance of LC-MS-based clinical proteomics platforms. Reviewed here are the recent advances in LC-MS and its applications in cancer biomarker discovery and quantification, along with the potentials, limitations and future perspectives.

  5. Enantioselective analysis of etodolac in human plasma by LC-MS/MS: Application to clinical pharmacokinetics.

    PubMed

    de Miranda Silva, Carolina; Rocha, Adriana; Tozatto, Eduardo; da Silva, Lucienir Maria; Donadi, Eduardo Antônio; Lanchote, Vera Lucia

    2016-02-20

    Etodolac is a non-steroidal anti-inflammatory drug with preferential inhibition of cyclooxigenase-2 and is widely used in the management of pain in patients with inflammatory arthritis. Etodolac is available as a racemic mixture of (-)-(R)-Etodolac and (+)-(S)-Etodolac; cyclooxigenases inhibition is attributed to (+)-(S)-Etodolac. According to our knowledge, this is the first method for determination of etodolac enantiomers in plasma using LC-MS/MS. Plasma extraction were performed with 25μL of plasma and 1mL of n-hexane:ethyl acetate (95:5); racemic ibuprofen was used as internal standard. Resolution of enantiomers were performed in a Chiralcel(®)OD-H column; deprotonated [M-H](-) and their respective ion products were monitored at transitions of 286>242 for etodolac enantiomers and 205>161 for ibuprofen. The quantitation limit was 3.2ng/mL for both enantiomers in plasma. The method was applied to study the pharmacokinetics of etodolac enantiomers after the administration of a 300 and 400mg dose of racemic drug to a healthy volunteer. Analysis of plasma samples showed higher plasma concentration of (-)-(R)-Etodolacfor both doses (300mg dose: AUC(0-∞)49.80 versus 4.55ugh/mL;400mg dose: AUC(0-∞) 63.90 versus 6.00ugh/mL) with an (R)-(+)/(S)-(-) ratio of approximately 11. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. The flexibility of a generic LC-MS/MS method for the quantitative analysis of therapeutic proteins based on human immunoglobulin G and related constructs in animal studies.

    PubMed

    Lanshoeft, Christian; Wolf, Thierry; Walles, Markus; Barteau, Samuel; Picard, Franck; Kretz, Olivier; Cianférani, Sarah; Heudi, Olivier

    2016-11-30

    An increasing demand of new analytical methods is associated with the growing number of biotherapeutic programs being prosecuted in the pharmaceutical industry. Whilst immunoassay has been the standard method for decades, a great interest in assays based on liquid chromatography tandem mass spectrometry (LC-MS/MS) is evolving. In this present work, the development of a generic method for the quantitative analysis of therapeutic proteins based on human immunoglobulin G (hIgG) in rat serum is reported. The method is based on four generic peptides GPSVFPLAPSSK (GPS), TTPPVLDSDGSFFLYSK (TTP), VVSVLTVLHQDWLNGK (VVS) and FNWYVDGVEVHNAK (FNW) originating from different parts of the fraction crystallizable (Fc) region of a reference hIgG1 (hIgG1A). A tryptic pellet digestion of rat serum spiked with hIgG1A and a stable isotope labeled protein (hIgG1B) used as internal standard (ISTD) was applied prior LC-MS/MS analysis. The upper limit of quantification was at 1000μg/mL. The lower limit of quantitation was for GPS, TTP and VVS at 1.00μg/mL whereas for FNW at 5.00μg/mL. Accuracy and precision data met acceptance over three days. The presented method was further successfully applied to the quantitative analysis of other hIgG1s (hIgG1C and hIgG1D) and hIgG4-based therapeutic proteins on spiked quality control (QC) samples in monkey and rat serum using calibration standards (Cs) prepared with hIgG1A in rat serum. In order to extend the applicability of our generic approach, a bispecific-bivalent hIgG1 (bb-hIgG1) and two lysine conjugated antibody-drug conjugates (ADC1 and ADC2) were incorporated as well. The observed values on spiked QC samples in monkey serum were satisfactory with GPS for the determination of bb-hIgG1 whereas the FNW and TTP peptides were suitable for the ADCs. Moreover, comparable mean concentration-time profiles were obtained from monkeys previously dosed intravenously with ADC2 measured against Cs samples prepared either with hIgG1A in rat serum

  7. Quantitative proteomic analysis of Pseudomonas pseudoalcaligenes CECT5344 in response to industrial cyanide-containing wastewaters using Liquid Chromatography-Mass Spectrometry/Mass Spectrometry (LC-MS/MS)

    PubMed Central

    Ibáñez, María Isabel; Cabello, Purificación; Luque-Almagro, Víctor Manuel; Sáez, Lara P.; Olaya, Alfonso; Sánchez de Medina, Verónica; Luque de Castro, María Dolores; Moreno-Vivián, Conrado; Roldán, María Dolores

    2017-01-01

    Biological treatments to degrade cyanide are a powerful technology for cyanide removal from industrial wastewaters. It has been previously demonstrated that the alkaliphilic bacterium Pseudomonas pseudoalcaligenes CECT5344 is able to use free cyanide and several metal−cyanide complexes as the sole nitrogen source. In this work, the strain CECT5344 has been used for detoxification of the different chemical forms of cyanide that are present in alkaline wastewaters from the jewelry industry. This liquid residue also contains large concentrations of metals like iron, copper and zinc, making this wastewater even more toxic. To elucidate the molecular mechanisms involved in the bioremediation process, a quantitative proteomic analysis by LC-MS/MS has been carried out in P. pseudoalcaligenes CECT5344 cells grown with the jewelry residue as sole nitrogen source. Different proteins related to cyanide and cyanate assimilation, as well as other proteins involved in transport and resistance to metals were induced by the cyanide-containing jewelry residue. GntR-like regulatory proteins were also induced by this industrial residue and mutational analysis revealed that GntR-like regulatory proteins may play a role in the regulation of cyanide assimilation in P. pseudoalcaligenes CECT5344. The strain CECT5344 has been used in a batch reactor to remove at pH 9 the different forms of cyanide present in industrial wastewaters from the jewelry industry (0.3 g/L, ca. 12 mM total cyanide, including both free cyanide and metal−cyanide complexes). This is the first report describing the biological removal at alkaline pH of such as elevated concentration of cyanide present in a heterogeneous mixture from an industrial source. PMID:28253357

  8. Quantitative proteomic analysis of Pseudomonas pseudoalcaligenes CECT5344 in response to industrial cyanide-containing wastewaters using Liquid Chromatography-Mass Spectrometry/Mass Spectrometry (LC-MS/MS).

    PubMed

    Ibáñez, María Isabel; Cabello, Purificación; Luque-Almagro, Víctor Manuel; Sáez, Lara P; Olaya, Alfonso; Sánchez de Medina, Verónica; Luque de Castro, María Dolores; Moreno-Vivián, Conrado; Roldán, María Dolores

    2017-01-01

    Biological treatments to degrade cyanide are a powerful technology for cyanide removal from industrial wastewaters. It has been previously demonstrated that the alkaliphilic bacterium Pseudomonas pseudoalcaligenes CECT5344 is able to use free cyanide and several metal-cyanide complexes as the sole nitrogen source. In this work, the strain CECT5344 has been used for detoxification of the different chemical forms of cyanide that are present in alkaline wastewaters from the jewelry industry. This liquid residue also contains large concentrations of metals like iron, copper and zinc, making this wastewater even more toxic. To elucidate the molecular mechanisms involved in the bioremediation process, a quantitative proteomic analysis by LC-MS/MS has been carried out in P. pseudoalcaligenes CECT5344 cells grown with the jewelry residue as sole nitrogen source. Different proteins related to cyanide and cyanate assimilation, as well as other proteins involved in transport and resistance to metals were induced by the cyanide-containing jewelry residue. GntR-like regulatory proteins were also induced by this industrial residue and mutational analysis revealed that GntR-like regulatory proteins may play a role in the regulation of cyanide assimilation in P. pseudoalcaligenes CECT5344. The strain CECT5344 has been used in a batch reactor to remove at pH 9 the different forms of cyanide present in industrial wastewaters from the jewelry industry (0.3 g/L, ca. 12 mM total cyanide, including both free cyanide and metal-cyanide complexes). This is the first report describing the biological removal at alkaline pH of such as elevated concentration of cyanide present in a heterogeneous mixture from an industrial source.

  9. Comparison of ESI- and APCI-LC-MS/MS methods: A case study of levonorgestrel in human plasma.

    PubMed

    Wang, Rulin; Zhang, Lin; Zhang, Zunjian; Tian, Yuan

    2016-12-01

    Electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) techniques for liquid chromatography-tandem mass spectrometry (LC-MS/MS) determination of levonorgestrel were evaluated. In consideration of difference in ionization mechanism, the two ionization sources were compared in terms of LC conditions, MS parameters and performance of method. The sensitivity for detection of levonorgestrel with ESI was 0.25 ng/mL which was lower than 1 ng/mL with APCI. Matrix effects were evaluated for levonorgestrel and canrenone (internal standard, IS) in human plasma, and the results showed that APCI source appeared to be slightly less liable to matrix effect than ESI source. With an overall consideration, ESI was chosen as a better ionization technique for rapid and sensitive quantification of levonorgestrel. The optimized LC-ESI-MS/MS method was validated for a linear range of 0.25-50 ng/mL with a correlation coefficient ≥0.99. The intra- and inter-batch precision and accuracy were within 11.72% and 6.58%, respectively. The application of this method was demonstrated by a bioequivalence study following a single oral administration of 1.5 mg levonorgestrel tablets in 21 Chinese healthy female volunteers.

  10. Simultaneous quantitation of multiple contraceptive hormones in human serum by LC-MS/MS.

    PubMed

    Blue, Steven W; Winchell, Andrea J; Kaucher, Amy V; Lieberman, Rachel A; Gilles, Christopher T; Pyra, Maria N; Heffron, Renee; Hou, Xuanlin; Coombs, Robert W; Nanda, Kavita; Davis, Nicole L; Kourtis, Athena P; Herbeck, Joshua T; Baeten, Jared M; Lingappa, Jairam R; Erikson, David W

    2018-04-01

    The objective was to develop a method to simultaneously quantify five commonly used hormonal contraceptives (HCs) and two endogenous sex steroids by liquid chromatography-tandem triple quadrupole mass spectrometry (LC-MS/MS) and apply this method to human serum samples. We developed a method to simultaneously analyze ethinyl estradiol (EE2), etonogestrel (ENG), levonorgestrel (LNG), medroxyprogesterone acetate (MPA) and norethisterone (NET), along with estradiol (E2) and progesterone (P4), in human serum for a Shimadzu Nexera-LCMS-8050 LC-MS/MS platform. We analyzed serum collected from women self-reporting use of oral contraceptives, contraceptive implants or injectable contraceptives (n=14) and normally cycling women using no HC (n=15) as well as pooled samples from women administered various HCs (ENG, n=6; LNG, n=14; MPA, n=7; NET, n=5). Limits of quantitation were 0.010ng/mL for E2, EE2 and P4; 0.020ng/mL for ENG, LNG and MPA; and 0.040ng/mL for NET. Precisions for all assays, as indicated by coefficient of variation, were less than or equal to 12.1%. Accuracies for all assays were in the range of 95%-108%. Endogenous hormone values obtained from analysis of human serum samples are in agreement with levels previously reported in the literature for normally cycling women as well as for women taking the appropriate HC. We have developed a robust, accurate and sensitive method for simultaneously analyzing commonly used contraceptive steroids and endogenous sex steroids in human serum. This analytical method can be used for quantitating contraceptive steroid levels in women for monitoring systemic exposure to determine drug interactions, nonadherence, misreporting and proper dosing. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Systematic Assessment of Seven Solvent and Solid-Phase Extraction Methods for Metabolomics Analysis of Human Plasma by LC-MS

    NASA Astrophysics Data System (ADS)

    Sitnikov, Dmitri G.; Monnin, Cian S.; Vuckovic, Dajana

    2016-12-01

    The comparison of extraction methods for global metabolomics is usually executed in biofluids only and focuses on metabolite coverage and method repeatability. This limits our detailed understanding of extraction parameters such as recovery and matrix effects and prevents side-by-side comparison of different sample preparation strategies. To address this gap in knowledge, seven solvent-based and solid-phase extraction methods were systematically evaluated using standard analytes spiked into both buffer and human plasma. We compared recovery, coverage, repeatability, matrix effects, selectivity and orthogonality of all methods tested for non-lipid metabolome in combination with reversed-phased and mixed-mode liquid chromatography mass spectrometry analysis (LC-MS). Our results confirmed wide selectivity and excellent precision of solvent precipitations, but revealed their high susceptibility to matrix effects. The use of all seven methods showed high overlap and redundancy which resulted in metabolite coverage increases of 34-80% depending on LC-MS method employed as compared to the best single extraction protocol (methanol/ethanol precipitation) despite 7x increase in MS analysis time and sample consumption. The most orthogonal methods to methanol-based precipitation were ion-exchange solid-phase extraction and liquid-liquid extraction using methyl-tertbutyl ether. Our results help facilitate rational design and selection of sample preparation methods and internal standards for global metabolomics.

  12. Profile-Based LC-MS Data Alignment—A Bayesian Approach

    PubMed Central

    Tsai, Tsung-Heng; Tadesse, Mahlet G.; Wang, Yue; Ressom, Habtom W.

    2014-01-01

    A Bayesian alignment model (BAM) is proposed for alignment of liquid chromatography-mass spectrometry (LC-MS) data. BAM belongs to the category of profile-based approaches, which are composed of two major components: a prototype function and a set of mapping functions. Appropriate estimation of these functions is crucial for good alignment results. BAM uses Markov chain Monte Carlo (MCMC) methods to draw inference on the model parameters and improves on existing MCMC-based alignment methods through 1) the implementation of an efficient MCMC sampler and 2) an adaptive selection of knots. A block Metropolis-Hastings algorithm that mitigates the problem of the MCMC sampler getting stuck at local modes of the posterior distribution is used for the update of the mapping function coefficients. In addition, a stochastic search variable selection (SSVS) methodology is used to determine the number and positions of knots. We applied BAM to a simulated data set, an LC-MS proteomic data set, and two LC-MS metabolomic data sets, and compared its performance with the Bayesian hierarchical curve registration (BHCR) model, the dynamic time-warping (DTW) model, and the continuous profile model (CPM). The advantage of applying appropriate profile-based retention time correction prior to performing a feature-based approach is also demonstrated through the metabolomic data sets. PMID:23929872

  13. Determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis

    NASA Astrophysics Data System (ADS)

    Liu, Ping; Qi, Chu-Bo; Zhu, Quan-Fei; Yuan, Bi-Feng; Feng, Yu-Qi

    2016-02-01

    Precursor ion scan and multiple reaction monitoring scan (MRM) are two typical scan modes in mass spectrometry analysis. Here, we developed a strategy by combining stable isotope labeling (IL) with liquid chromatography-mass spectrometry (LC-MS) under double precursor ion scan (DPI) and MRM for analysis of thiols in 5 types of human cancer urine. Firstly, the IL-LC-DPI-MS method was applied for non-targeted profiling of thiols from cancer samples. Compared to traditional full scan mode, the DPI method significantly improved identification selectivity and accuracy. 103 thiol candidates were discovered in all cancers and 6 thiols were identified by their standards. It is worth noting that pantetheine, for the first time, was identified in human urine. Secondly, the IL-LC-MRM-MS method was developed for relative quantification of thiols in cancers compared to healthy controls. All the MRM transitions of light and heavy labeled thiols were acquired from urines by using DPI method. Compared to DPI method, the sensitivity of MRM improved by 2.1-11.3 folds. In addition, the concentration of homocysteine, γ-glutamylcysteine and pantetheine enhanced more than two folds in cancer patients compared to healthy controls. Taken together, the method demonstrated to be a promising strategy for identification and comprehensive quantification of thiols in human urines.

  14. METHOD 544. DETERMINATION OF MICROCYSTINS AND NODULARIN IN DRINKING WATER BY SOLID PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/TANDEM MASS SPECTROMETRY (LC/MS/MS)

    EPA Science Inventory

    Method 544 is an accurate and precise analytical method to determine six microcystins (including MC-LR) and nodularin in drinking water using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE-LC/MS/MS). The advantage of this SPE-LC/MS/MS is its sensi...

  15. High rates of non-adherence to antihypertensive treatment revealed by high-performance liquid chromatography-tandem mass spectrometry (HP LC-MS/MS) urine analysis

    PubMed Central

    Tomaszewski, Maciej; White, Christobelle; Patel, Prashanth; Masca, Nicholas; Damani, Ravi; Hepworth, Joanne; Samani, Nilesh J; Gupta, Pankaj; Madira, Webster; Stanley, Adrian; Williams, Bryan

    2014-01-01

    Objectives Non-adherence to therapy is an important cause of suboptimal blood pressure control but few practical tools exist to accurately and routinely detect it. We used a simple urine-based assay to evaluate the prevalence of antihypertensive treatment non-adherence and its impact on blood pressure in a specialist hypertension centre. Methods 208 hypertensive patients (125 new referrals, 66 follow-up patients with inadequate blood pressure control and 17 renal denervation referrals) underwent assessment of antihypertensive drug intake using high-performance liquid chromatography-tandem mass spectrometry (HP LC-MS/MS) urine analysis at the time of clinical appointment. A total of 40 most commonly prescribed antihypertensive medications (or their metabolites) were screened for in spot urine samples. Results Overall, 25% of patients were totally or partially non-adherent to antihypertensive treatment (total non-adherence 10.1%, partial non-adherence 14.9%). The highest prevalence of partial and total non-adherence was among follow-up patients with inadequate blood pressure control (28.8%) and those referred for consideration of renal denervation (23.5%), respectively. There was a linear relationship between blood pressure and the numerical difference in detected/prescribed antihypertensive medications—every unit increase in this difference was associated with 3.0 (1.1) mm Hg, 3.1 (0.7) mm Hg and 1.9 (0.7) mm Hg increase in adjusted clinic systolic blood pressure, clinic diastolic blood pressure (DBP) and 24 h mean daytime DBP (p=0.0051, p=8.62×10−6, p=0.0057), respectively. Conclusions Non-adherence to blood pressure lowering therapy is common, particularly in patients with suboptimal blood pressure control and those referred for renal denervation. HP LC-MS/MS urine analysis could be used to exclude non-adherence and better stratify further investigations and intervention. PMID:24694797

  16. Less label, more free: approaches in label-free quantitative mass spectrometry.

    PubMed

    Neilson, Karlie A; Ali, Naveid A; Muralidharan, Sridevi; Mirzaei, Mehdi; Mariani, Michael; Assadourian, Gariné; Lee, Albert; van Sluyter, Steven C; Haynes, Paul A

    2011-02-01

    In this review we examine techniques, software, and statistical analyses used in label-free quantitative proteomics studies for area under the curve and spectral counting approaches. Recent advances in the field are discussed in an order that reflects a logical workflow design. Examples of studies that follow this design are presented to highlight the requirement for statistical assessment and further experiments to validate results from label-free quantitation. Limitations of label-free approaches are considered, label-free approaches are compared with labelling techniques, and forward-looking applications for label-free quantitative data are presented. We conclude that label-free quantitative proteomics is a reliable, versatile, and cost-effective alternative to labelled quantitation. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. SIMPATIQCO: a server-based software suite which facilitates monitoring the time course of LC-MS performance metrics on Orbitrap instruments.

    PubMed

    Pichler, Peter; Mazanek, Michael; Dusberger, Frederico; Weilnböck, Lisa; Huber, Christian G; Stingl, Christoph; Luider, Theo M; Straube, Werner L; Köcher, Thomas; Mechtler, Karl

    2012-11-02

    While the performance of liquid chromatography (LC) and mass spectrometry (MS) instrumentation continues to increase, applications such as analyses of complete or near-complete proteomes and quantitative studies require constant and optimal system performance. For this reason, research laboratories and core facilities alike are recommended to implement quality control (QC) measures as part of their routine workflows. Many laboratories perform sporadic quality control checks. However, successive and systematic longitudinal monitoring of system performance would be facilitated by dedicated automatic or semiautomatic software solutions that aid an effortless analysis and display of QC metrics over time. We present the software package SIMPATIQCO (SIMPle AuTomatIc Quality COntrol) designed for evaluation of data from LTQ Orbitrap, Q-Exactive, LTQ FT, and LTQ instruments. A centralized SIMPATIQCO server can process QC data from multiple instruments. The software calculates QC metrics supervising every step of data acquisition from LC and electrospray to MS. For each QC metric the software learns the range indicating adequate system performance from the uploaded data using robust statistics. Results are stored in a database and can be displayed in a comfortable manner from any computer in the laboratory via a web browser. QC data can be monitored for individual LC runs as well as plotted over time. SIMPATIQCO thus assists the longitudinal monitoring of important QC metrics such as peptide elution times, peak widths, intensities, total ion current (TIC) as well as sensitivity, and overall LC-MS system performance; in this way the software also helps identify potential problems. The SIMPATIQCO software package is available free of charge.

  18. Fluorescently labelled multiplex lateral flow immunoassay based on cadmium-free quantum dots.

    PubMed

    Beloglazova, Natalia V; Sobolev, Aleksander M; Tessier, Mickael D; Hens, Zeger; Goryacheva, Irina Yu; De Saeger, Sarah

    2017-03-01

    A sensitive tool for simultaneous qualitative detection of two mycotoxins based on use of non-cadmium quantum dots (QDs) is presented for the first time. QDs have proven themselves as promising fluorescent labels for biolabeling and chemical analysis. With an increasing global tendency to regulate and limit the use of hazardous elements, indium phosphide (InP) QDs are highlighted as environmentally-friendly alternatives to the highly efficient and well-studied, but potentially toxic Cd- and Pb-based QDs. Here, we developed water-soluble InP QDs-based fluorescent nanostructures. They consisted of core/shell InP/ZnS QDs enrobed in a silica shell that allowed the water solubility (QD@SiO 2 ). Then we applied the QD@SiO 2 as novel, silica shell-encapsulated fluorescent labels in immunoassays for rapid multiplexed screening. Two mycotoxins, zearalenone and deoxynivalenol, were simultaneously detected in maize and wheat, since the two QD@SiO 2 labelled conjugates emit at two different, individually detectable wavelengths. The cutoff values for the simultaneous determination were 50 and 500μgkg -1 for zearalenone and deoxynivalenol, respectively, in both maize and wheat. Liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) was used to confirm the result. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. A flexible statistical model for alignment of label-free proteomics data – incorporating ion mobility and product ion information

    PubMed Central

    2013-01-01

    Background The goal of many proteomics experiments is to determine the abundance of proteins in biological samples, and the variation thereof in various physiological conditions. High-throughput quantitative proteomics, specifically label-free LC-MS/MS, allows rapid measurement of thousands of proteins, enabling large-scale studies of various biological systems. Prior to analyzing these information-rich datasets, raw data must undergo several computational processing steps. We present a method to address one of the essential steps in proteomics data processing - the matching of peptide measurements across samples. Results We describe a novel method for label-free proteomics data alignment with the ability to incorporate previously unused aspects of the data, particularly ion mobility drift times and product ion information. We compare the results of our alignment method to PEPPeR and OpenMS, and compare alignment accuracy achieved by different versions of our method utilizing various data characteristics. Our method results in increased match recall rates and similar or improved mismatch rates compared to PEPPeR and OpenMS feature-based alignment. We also show that the inclusion of drift time and product ion information results in higher recall rates and more confident matches, without increases in error rates. Conclusions Based on the results presented here, we argue that the incorporation of ion mobility drift time and product ion information are worthy pursuits. Alignment methods should be flexible enough to utilize all available data, particularly with recent advancements in experimental separation methods. PMID:24341404

  20. Design of experiments as a tool for LC-MS/MS method development for the trace analysis of the potentially genotoxic 4-dimethylaminopyridine impurity in glucocorticoids.

    PubMed

    Székely, Gy; Henriques, B; Gil, M; Ramos, A; Alvarez, C

    2012-11-01

    The present study reports on a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method development strategy supported by design of experiments (DoE) for the trace analysis of 4-dimethylaminopyridine (DMAP). The conventional approaches for development of LC-MS/MS methods are usually via trial and error, varying intentionally the experimental factors which is time consuming and interactions between experimental factors are not considered. The LC factors chosen for the DoE study include flow (F), gradient (G) and injection volume (V(inj)) while cone voltage (E(con)) and collision energy (E(col)) were chosen as MS parameters. All of the five factors were studied simultaneously. The method was optimized with respect to four responses: separation of peaks (Sep), peak area (A(peak)), length of the analysis (T) and the signal to noise ratio (S/N). A quadratic model, namely central composite face (CCF) featuring 29 runs was used instead of a less powerful linear model since the increase in the number of injections was insignificant. In order to determine the robustness of the method a new set of DoE experiments was carried out applying robustness around the optimal conditions was evaluated applying a fractional factorial of resolution III with 11 runs, wherein additional factors - such as column temperature and quadrupole resolution - were considered. The method utilizes a Phenomenex Gemini NX C-18 HPLC analytical column with electrospray ionization and a triple quadrupole mass detector in multiple reaction monitoring (MRM) mode, resulting in short analyses with a 10min runtime. Drawbacks of derivatization, namely incomplete reaction and time consuming sample preparation, have been avoided and the change from SIM to MRM mode resulted in increased sensitivity and lower LOQ. The DoE method development strategy led to a method allowing the trace analysis of DMAP at 0.5 ng/ml absolute concentration which corresponds to a 0.1 ppm limit of quantification in 5mg

  1. A universal denoising and peak picking algorithm for LC-MS based on matched filtration in the chromatographic time domain.

    PubMed

    Andreev, Victor P; Rejtar, Tomas; Chen, Hsuan-Shen; Moskovets, Eugene V; Ivanov, Alexander R; Karger, Barry L

    2003-11-15

    A new denoising and peak picking algorithm (MEND, matched filtration with experimental noise determination) for analysis of LC-MS data is described. The algorithm minimizes both random and chemical noise in order to determine MS peaks corresponding to sample components. Noise characteristics in the data set are experimentally determined and used for efficient denoising. MEND is shown to enable low-intensity peaks to be detected, thus providing additional useful information for sample analysis. The process of denoising, performed in the chromatographic time domain, does not distort peak shapes in the m/z domain, allowing accurate determination of MS peak centroids, including low-intensity peaks. MEND has been applied to denoising of LC-MALDI-TOF-MS and LC-ESI-TOF-MS data for tryptic digests of protein mixtures. MEND is shown to suppress chemical and random noise and baseline fluctuations, as well as filter out false peaks originating from the matrix (MALDI) or mobile phase (ESI). In addition, MEND is shown to be effective for protein expression analysis by allowing selection of a large number of differentially expressed ICAT pairs, due to increased signal-to-noise ratio and mass accuracy.

  2. Direct aqueous measurement of 25-hydroxyvitamin D levels in a cellular environment by LC-MS/MS using the novel chemical derivatization reagent MDBP.

    PubMed

    Müller, Miriam J; Bruns, Heiko; Volmer, Dietrich A

    2017-04-01

    Vitamin D measurements in biological fluids by mass spectrometry are challenging at very low concentration levels. As a result, chemical derivatization is often employed to enhance the ionization properties of low abundant vitamin D compounds. Cookson-type reagents such as 4-phenyl-1,2,4-triazoline-3,5-dione (PTAD) or similar derivatives work well but require careful, water-free experimental conditions, as traces of water inactivate the reagent and inhibit or stop the derivatization reactions, thus making quantitative measurements in aqueous samples impossible. We describe a novel electrospray liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for determining 25-hydroxyvitamin D 3 (25(OH)D 3 ) directly in aqueous cellular systems using a new derivatization reagent, the ionic liquid 12-(maleimidyl)dodecyl-tri-n-butylphosphonium bromide (MDBP). The proof-of-concept for the MDBP assay was demonstrated by measuring the levels of 25(OH)D 3 in four different human cell types, namely T cells, helper T cells, B cells, and macrophages. In addition to the ability to determine the levels of 25(OH)D 3 directly in aqueous samples, the cellular integrity was maintained in our application. We show the time-dependent uptake of 25(OH)D 3 into the investigated cells to demonstrate the applicability of the new label. Furthermore, the MDBP derivatization technique may be equally useful in imaging mass spectrometry, where it could be used for response enhancements of spatially localized vitamin D metabolites on wet tissue surfaces, without destroying the integrity of the tissue surface. Graphical Abstract MDBP labelling of 25-hydroxyvitamin D in the extracellular space.

  3. Assessment of human deoxynivalenol exposure using an LC-MS/MS based biomarker method.

    PubMed

    Warth, Benedikt; Sulyok, Michael; Fruhmann, Philipp; Berthiller, Franz; Schuhmacher, Rainer; Hametner, Christian; Adam, Gerhard; Fröhlich, Johannes; Krska, Rudolf

    2012-05-20

    The Fusarium toxin deoxynivalenol (DON) is one of the most abundant mycotoxins worldwide and poses many adverse health effects to human and animals. Consequently, regulatory limits and a provisional maximum tolerable daily intake (PMTDI) for this important type B-trichothecene were assigned. We conducted a pilot survey to investigate the level of DON exposure in Austrian adults by measurements of DON and its glucuronide conjugates (DON-GlcA's), as biomarkers of exposure, in first morning urine. The average concentration of total DON (free DON+DON-GlcA's) was estimated to be 20.4±2.4 μg L⁻¹ (max. 63 μg L⁻¹). Surprisingly, we found that one third of the volunteers (n=27) exceeded the established PMTDI when consuming regular diet. DON-GlcA's were directly quantified by LC-MS/MS and the results were compared with indirect quantification after enzymatic hydrolysis and confirmed the suitability of the direct method. Moreover, we investigated the in vivo metabolism of DON in humans and were able to determine two closely eluting DON-GlcA's in naturally contaminated urine samples for the first time. In contrast to previous findings we have tentatively identified DON-15-glucuronide as a major DON metabolite in human urine based on the analysis of these samples. About 75% of total glucuronides were derived from this metabolite while DON-3-glucuronide accounted for approximately 25%. The reported new findings clearly demonstrate the great potential of suitable biomarkers to critically assess exposure of humans and animals to DON. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  4. Study of sample preparation for determination of endocannabinoids and analogous compounds in human serum by LC-MS/MS in MRM mode.

    PubMed

    Luque-Córdoba, D; Calderón-Santiago, M; Luque de Castro, M D; Priego-Capote, F

    2018-08-01

    Endocannabinoids are lipids with a key role in physiological processes such as the immune response or the metabolism. This involvement explains their association to pathologies such as cancer, obesity or multiple sclerosis. The determination of endocannabinoids constitutes a challenge for clinical laboratories due to the variety of biological matrices and the wide range of concentrations at which they can be found. This research deals with the comparison of three sample preparation strategies (viz., on-line SPE, off-line SPE for interferents removal, and protein precipitation) for subsequent LC-MS/MS analysis of 14 endocannabinoids and analogous compounds in serum. As a result, the on-line coupling between SPE and LC-MS/MS is proposed as the best approach for this determination. The proposed method allows full automation of the overall process, shortening of the analysis time, and avoidance of errors associated with sample preparation steps. The improvement in sensitivity and selectivity thus achieved allows obtaining quantification limits at the pg mL -1 level, which makes possible the application of the method for clinical studies. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. An improved method for fast and selective separation of carotenoids by LC-MS.

    PubMed

    Abate-Pella, Daniel; Freund, Dana M; Slovin, Janet P; Hegeman, Adrian D; Cohen, Jerry D

    2017-11-01

    Carotenoids are a large class of compounds that are biosynthesized by condensation of isoprene units in plants, fungi, bacteria, and some animals. They are characteristically highly conjugated through double bonds, which lead to many isomers as well susceptibility to oxidation and other chemical modifications. Carotenoids are important because of their potent antioxidant activity and are the pigments responsible for color in a wide variety of foods. Human consumption is correlated to many health benefits including prevention of cancer, cardiovascular disease, and age-related disease. Extreme hydrophobicity, poor stability, and low concentration in biological samples make these compounds difficult to analyze and difficult to develop analytical methods for aimed towards identification and quantification. Examples in the literature frequently report the use of exotic stationary phases, solvents, and additives, such as ethyl acetate, dichloromethane, and methyl tert-butyl ether that are incompatible with liquid chromatography mass spectrometry (LC-MS). In order to address these issues, we implemented the use of LC-MS friendly conditions using a low-hydrophobicity cyano-propyl column (Agilent Zorbax SB-CN). We successfully differentiated between isomeric carotenoids by optimizing two gradient methods and using a mixture of 11 standards and LC-MS in positive ionization mode. Three complex biological samples from strawberry leaf, chicken feed supplement, and the photosynthetic bacterium Chloroflexus aurantiacus were analyzed and several carotenoids were resolved in these diverse backgrounds. Our results show this methodology is a significant improvement over other alternatives for analyzing carotenoids because of its ease of use, rapid analysis time, high selectivity, and, most importantly, its compatibility with typical LC-MS conditions. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. The future of liquid chromatography-mass spectrometry (LC-MS) in metabolic profiling and metabolomic studies for biomarker discovery

    PubMed Central

    Metz, Thomas O.; Zhang, Qibin; Page, Jason S.; Shen, Yufeng; Callister, Stephen J.; Jacobs, Jon M.; Smith, Richard D.

    2008-01-01

    SUMMARY The future utility of liquid chromatography-mass spectrometry (LC-MS) in metabolic profiling and metabolomic studies for biomarker discover will be discussed, beginning with a brief description of the evolution of metabolomics and the utilization of the three most popular analytical platforms in such studies: NMR, GC-MS, and LC-MS. Emphasis is placed on recent developments in high-efficiency LC separations, sensitive electrospray ionization approaches, and the benefits to incorporating both in LC-MS-based approaches. The advantages and disadvantages of various quantitative approaches are reviewed, followed by the current LC-MS-based tools available for candidate biomarker characterization and identification. Finally, a brief prediction on the future path of LC-MS-based methods in metabolic profiling and metabolomic studies is given. PMID:19177179

  7. QUANTIFICATION OF 2,4-D ON SOLID-PHASE EXPOSURE SAMPLING MEDIA BY LC/MS/MS

    EPA Science Inventory

    Three types of solid phase chemical exposure sampling media: cellulose, polyurethane foam (PUF) and XAD-2, were analyzed for 2,4-D and the amine salts of 2,4-D. Individual samples were extracted into acidified methanol and the extracts were analyzed via LC/MS/MS using electrospra...

  8. Oxidation of danofloxacin by free chlorine-kinetic study, structural identification of by-products by LC-MS/MS and potential toxicity of by-products using in silico test.

    PubMed

    Yassine, Montaha; Rifai, Ahmad; Doumyati, Samah; Trivella, Aurélien; Mazellier, Patrick; Budzinski, Hélène; Al Iskandarani, Mohamad

    2017-03-01

    In this study, we aimed to investigate the kinetics and the mechanism of reaction of the fluoroquinolone antibacterial danofloxacin (DANO) by free available chlorine (FAC) during water chlorination process. Kinetic study was thus performed at pH 7.2, 20 °C in the presence of an excess of total chlorine. Under these experimental conditions, a second-order reaction rate constant (first-order relative to DANO concentration and first-order relative to FAC concentration) was evaluated to k~1446 M -1  s -1 . Five degradation products were identified at different reaction times. Their structures were investigated by using fragmentations obtained at different CID collision energies in MS/MS experiments. Moreover, the toxicity of the proposed structures was predicted by using T.E.S.T. The results indicated that all by-products may have a developmental toxicity. The oral rat LD 50 concentration was predicted to be lower than that of DANO. Furthermore, two degradation compounds presented a concentration level for fathead minnow LC 50 (96 h) lower than that of DANO and presented toxicity for the marine animals.

  9. Top-down approach for the direct characterization of low molecular weight heparins using LC-FT-MS.

    PubMed

    Li, Lingyun; Zhang, Fuming; Zaia, Joseph; Linhardt, Robert J

    2012-10-16

    Low molecular heparins (LMWHs) are structurally complex, heterogeneous, polydisperse, and highly negatively charged mixtures of polysaccharides. The direct characterization of LMWH is a major challenge for currently available analytical technologies. Electrospray ionization (ESI) liquid chromatography-mass spectrometry (LC-MS) is a powerful tool for the characterization complex biological samples in the fields of proteomics, metabolomics, and glycomics. LC-MS has been applied to the analysis of heparin oligosaccharides, separated by size exclusion, reversed phase ion-pairing chromatography, and chip-based amide hydrophilic interaction chromatography (HILIC). However, there have been limited applications of ESI-LC-MS for the direct characterization of intact LMWHs (top-down analysis) due to their structural complexity, low ionization efficiency, and sulfate loss. Here we present a simple and reliable HILIC-Fourier transform (FT)-ESI-MS platform to characterize and compare two currently marketed LMWH products using the top-down approach requiring no special sample preparation steps. This HILIC system relies on cross-linked diol rather than amide chemistry, affording highly resolved chromatographic separations using a relatively high percentage of acetonitrile in the mobile phase, resulting in stable and high efficiency ionization. Bioinformatics software (GlycReSoft 1.0) was used to automatically assign structures within 5-ppm mass accuracy.

  10. Simultaneous determination of 18 abused opioids and metabolites in human hair using LC-MS/MS and illegal opioids abuse proven by hair analysis.

    PubMed

    Kim, Jihyun; Ji, Dajeong; Kang, Soyoung; Park, Meejung; Yang, Wonkyung; Kim, Eunmi; Choi, Hwakyung; Lee, Sooyeun

    2014-02-01

    Natural and synthetic opioids have efficient analgesic activity but can also be addictive. Thus, the determination of opioids and their metabolites in biological specimens is of interest in clinical and forensic toxicology laboratories. The analysis of drugs in hair provides valuable information on previous chronic drug use and has been successfully applied to the diagnosis of drug abuse, tolerance, compliance and gestational drug exposure. Despite the abuse of prescription opioids along with heroin and other illegal opiates, few studies have been conducted on the simultaneous determination of the broad range of opioids covering those drugs in hair. In the present study, an analytical method for the simultaneous detection in hair of 18 opioids and metabolites considered to have a high abuse risk based on the results of urine drug screening was established and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the purpose of clinical and forensic applications. The drugs and metabolites were extracted from hair using methanol and analyzed using LC-MS/MS. The validation results proved that the method was selective, accurate and precise with acceptable linearity within calibration ranges. No significant variation was observed by different sources of matrices. The limits of detection and the limits of quantification ranged from 0.05 to 0.25ng/10mg hair and from 0.05 to 0.5ng/10mg hair, respectively. The developed method was successfully applied to 15 hair samples from opioids users. This method will be very useful for monitoring the inappropriate use of opioid drugs. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Comparison of Gluten Extraction Protocols Assessed by LC-MS/MS Analysis.

    PubMed

    Fallahbaghery, Azadeh; Zou, Wei; Byrne, Keren; Howitt, Crispin A; Colgrave, Michelle L

    2017-04-05

    The efficiency of gluten extraction is of critical importance to the results derived from any analytical method for gluten detection and quantitation, whether it employs reagent-based technology (antibodies) or analytical instrumentation (mass spectrometry). If the target proteins are not efficiently extracted, the end result will be an under-estimation in the gluten content posing a health risk to people affected by conditions such as celiac disease (CD) and nonceliac gluten sensitivity (NCGS). Five different extraction protocols were investigated using LC-MRM-MS for their ability to efficiently and reproducibly extract gluten. The rapid and simple "IPA/DTT" protocol and related "two-step" protocol were enriched for gluten proteins, 55/86% (trypsin/chymotrypsin) and 41/68% of all protein identifications, respectively, with both methods showing high reproducibility (CV < 15%). When using multistep protocols, it was critical to examine all fractions, as coextraction of proteins occurred across fractions, with significant levels of proteins existing in unexpected fractions and not all proteins within a particular gluten class behaving the same.

  12. Comparability analysis of protein therapeutics by bottom-up LC-MS with stable isotope-tagged reference standards

    PubMed Central

    Manuilov, Anton V; Radziejewski, Czeslaw H

    2011-01-01

    Comparability studies lie at the heart of assessments that evaluate differences amongst manufacturing processes and stability studies of protein therapeutics. Low resolution chromatographic and electrophoretic methods facilitate quantitation, but do not always yield detailed insight into the effect of the manufacturing change or environmental stress. Conversely, mass spectrometry (MS) can provide high resolution information on the molecule, but conventional methods are not very quantitative. This gap can be reconciled by use of a stable isotope-tagged reference standard (SITRS), a version of the analyte protein that is uniformly labeled with 13C6-arginine and 13C6-lysine. The SITRS serves as an internal control that is trypsin-digested and analyzed by liquid chromatography (LC)-MS with the analyte sample. The ratio of the ion intensities of each unlabeled and labeled peptide pair is then compared to that of other sample(s). A comparison of these ratios provides a readily accessible way to spot even minute differences among samples. In a study of a monoclonal antibody (mAb) spiked with varying amounts of the same antibody bearing point mutations, peptides containing the mutations were readily identified and quantified at concentrations as low as 2% relative to unmodified peptides. The method was robust, reproducible and produced a linear response for every peptide that was monitored. The method was also successfully used to distinguish between two batches of a mAb that were produced in two different cell lines while two batches produced from the same cell line were found to be highly comparable. Finally, the use of the SITRS method in the comparison of two stressed mAb samples enabled the identification of sites susceptible to deamidation and oxidation, as well as their quantitation. The experimental results indicate that use of a SITRS in a peptide mapping experiment with MS detection enables sensitive and quantitative comparability studies of proteins at high

  13. Development of an ESI-LC-MS-based assay for kinetic evaluation of Mycobacterium tuberculosis shikimate kinase activity and inhibition.

    PubMed

    Simithy, Johayra; Gill, Gobind; Wang, Yu; Goodwin, Douglas C; Calderón, Angela I

    2015-02-17

    A simple and reliable liquid chromatography-mass spectrometry (LC-MS) assay has been developed and validated for the kinetic characterization and evaluation of inhibitors of shikimate kinase from Mycobacterium tuberculosis (MtSK), a potential target for the development of novel antitubercular drugs. This assay is based on the direct determination of the reaction product shikimate-3-phosphate (S3P) using electrospray ionization (ESI) and a quadrupole time-of-flight (Q-TOF) detector. A comparative analysis of the kinetic parameters of MtSK obtained by the LC-MS assay with those obtained by a conventional UV-assay was performed. Kinetic parameters determined by LC-MS were in excellent agreement with those obtained from the UV assay, demonstrating the accuracy, and reliability of this method. The validated assay was successfully applied to the kinetic characterization of a known inhibitor of shikimate kinase; inhibition constants and mode of inhibition were accurately delineated with LC-MS.

  14. Comparison of clonazepam compliance by measurement of urinary concentration by immunoassay and LC-MS/MS in pain management population.

    PubMed

    West, Robert; Pesce, Amadeo; West, Cameron; Crews, Bridgit; Mikel, Charles; Almazan, Perla; Rosenthal, Murray; Latyshev, Sergey

    2010-01-01

    Physicians determine patient compliance with their medications by use of urine drug testing. It is known that measurement of benzodiazepines is limited by immunoassay specificity and cutoff limits and therefore does not offer physicians an accurate picture of their patients' compliance with these medications. A few studies have used lower cutoffs to demonstrate patient compliance. To define more appropriate cutoffs for compliance monitoring of patients prescribed clonazepam as determined using immunoassay and liquid chromatography-tandem mass spectrometry (LC-MS/MS). A diagnostic accuracy study of the urinary excretion of clonazepam. Millennium Laboratories performed measurements on the urinary excretion of pain patients prescribed clonazepam as the indicator test. This benzodiazepine was chosen because it forms one major metabolite, 7-aminoclonazepam which is specific for that drug. Patients whose only benzodiazepine medication was clonazepam were selected as the test population. The Millennium Laboratories test database was filtered first to select patients on clonazepam, then a second filter was used to eliminate patients with any other listed benzodiazepine medications. Samples were tested using the Microgenics DRI benzodiazepine assay with a 200 ng/mL cutoff. The same samples were quantitatively assessed for 7-aminoclonazepam by LC-MS/MS with a cutoff of 40 ng/mL. The results from the immunoassay were scored as positive or negative while the quantitative results from the LC-MS/MS were also scored as positive or negative depending upon their concentration. Samples from 180 patients met these medication criteria. The positivity rates were 21% (38 samples) by immunoassay. The positivity rate was 70% (126 samples) if the LC-MS/MS cutoff was set at 200 ng/mL. However, the positivity rate was 87% (157 samples) if the LC-MS/MS was set at 40 ng/mL. Concentration distributions revealed a significant fraction (7%) in the 40 - 100 ng/mL range. A limitation of the study

  15. Determining the Composition and Stability of Protein Complexes Using an Integrated Label-Free and Stable Isotope Labeling Strategy

    PubMed Central

    Greco, Todd M.; Guise, Amanda J.; Cristea, Ileana M.

    2016-01-01

    In biological systems, proteins catalyze the fundamental reactions that underlie all cellular functions, including metabolic processes and cell survival and death pathways. These biochemical reactions are rarely accomplished alone. Rather, they involve a concerted effect from many proteins that may operate in a directed signaling pathway and/or may physically associate in a complex to achieve a specific enzymatic activity. Therefore, defining the composition and regulation of protein complexes is critical for understanding cellular functions. In this chapter, we describe an approach that uses quantitative mass spectrometry (MS) to assess the specificity and the relative stability of protein interactions. Isolation of protein complexes from mammalian cells is performed by rapid immunoaffinity purification, and followed by in-solution digestion and high-resolution mass spectrometry analysis. We employ complementary quantitative MS workflows to assess the specificity of protein interactions using label-free MS and statistical analysis, and the relative stability of the interactions using a metabolic labeling technique. For each candidate protein interaction, scores from the two workflows can be correlated to minimize nonspecific background and profile protein complex composition and relative stability. PMID:26867737

  16. LC-MSsim – a simulation software for liquid chromatography mass spectrometry data

    PubMed Central

    Schulz-Trieglaff, Ole; Pfeifer, Nico; Gröpl, Clemens; Kohlbacher, Oliver; Reinert, Knut

    2008-01-01

    Background Mass Spectrometry coupled to Liquid Chromatography (LC-MS) is commonly used to analyze the protein content of biological samples in large scale studies. The data resulting from an LC-MS experiment is huge, highly complex and noisy. Accordingly, it has sparked new developments in Bioinformatics, especially in the fields of algorithm development, statistics and software engineering. In a quantitative label-free mass spectrometry experiment, crucial steps are the detection of peptide features in the mass spectra and the alignment of samples by correcting for shifts in retention time. At the moment, it is difficult to compare the plethora of algorithms for these tasks. So far, curated benchmark data exists only for peptide identification algorithms but no data that represents a ground truth for the evaluation of feature detection, alignment and filtering algorithms. Results We present LC-MSsim, a simulation software for LC-ESI-MS experiments. It simulates ESI spectra on the MS level. It reads a list of proteins from a FASTA file and digests the protein mixture using a user-defined enzyme. The software creates an LC-MS data set using a predictor for the retention time of the peptides and a model for peak shapes and elution profiles of the mass spectral peaks. Our software also offers the possibility to add contaminants, to change the background noise level and includes a model for the detectability of peptides in mass spectra. After the simulation, LC-MSsim writes the simulated data to mzData, a public XML format. The software also stores the positions (monoisotopic m/z and retention time) and ion counts of the simulated ions in separate files. Conclusion LC-MSsim generates simulated LC-MS data sets and incorporates models for peak shapes and contaminations. Algorithm developers can match the results of feature detection and alignment algorithms against the simulated ion lists and meaningful error rates can be computed. We anticipate that LC-MSsim will be

  17. Mass spectrometry (LC-MS/MS) identified proteomic biosignatures of breast cancer in proximal fluid.

    PubMed

    Whelan, Stephen A; He, Jianbo; Lu, Ming; Souda, Puneet; Saxton, Romaine E; Faull, Kym F; Whitelegge, Julian P; Chang, Helena R

    2012-10-05

    We have begun an early phase of biomarker discovery in three clinically important types of breast cancer using a panel of human cell lines: HER2 positive, hormone receptor positive and HER2 negative, and triple negative (HER2-, ER-, PR-). We identified and characterized the most abundant secreted, sloughed, or leaked proteins released into serum free media from these breast cancer cell lines using a combination of protein fractionation methods before LC-MS/MS mass spectrometry analysis. A total of 249 proteins were detected in the proximal fluid of 7 breast cancer cell lines. The expression of a selected group of high abundance and/or breast cancer-specific potential biomarkers including thromobospondin 1, galectin-3 binding protein, cathepsin D, vimentin, zinc-α2-glycoprotein, CD44, and EGFR from the breast cancer cell lines and in their culture media were further validated by Western blot analysis. Interestingly, mass spectrometry identified a cathepsin D protein single-nucleotide polymorphism (SNP) by alanine to valine replacement from the MCF-7 breast cancer cell line. Comparison of each cell line media proteome displayed unique and consistent biosignatures regardless of the individual group classifications, demonstrating the potential for stratification of breast cancer. On the basis of the cell line media proteome, predictive Tree software was able to categorize each cell line as HER2 positive, HER2 negative, and hormone receptor positive and triple negative based on only two proteins, muscle fructose 1,6-bisphosphate aldolase and keratin 19. In addition, the predictive Tree software clearly identified MCF-7 cell line overexpresing the HER2 receptor with the SNP cathepsin D biomarker.

  18. A simple, fast and sensitive screening LC-ESI-MS/MS method for antibiotics in fish.

    PubMed

    Guidi, Letícia Rocha; Santos, Flávio Alves; Ribeiro, Ana Cláudia S R; Fernandes, Christian; Silva, Luiza H M; Gloria, Maria Beatriz A

    2017-01-15

    The objective of this study was to develop and validate a fast, sensitive and simple liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method for the screening of six classes of antibiotics (aminoglycosides, beta-lactams, macrolides, quinolones, sulfonamides and tetracyclines) in fish. Samples were extracted with trichloroacetic acid. LC separation was achieved on a Zorbax Eclipse XDB C18 column and gradient elution using 0.1% heptafluorobutyric acid in water and acetonitrile as mobile phase. Analysis was carried out in multiple reaction monitoring mode via electrospray interface operated in the positive ionization mode, with sulfaphenazole as internal standard. The method was suitable for routine screening purposes of 40 antibiotics, according to EC Guidelines for the Validation of Screening Methods for Residues of Veterinary Medicines, taking into consideration threshold value, cut-off factor, detection capability, limit of detection, sensitivity and specificity. Real fish samples (n=193) from aquaculture were analyzed and 15% were positive for enrofloxacin (quinolone), one of them at a higher concentration than the level of interest (50µgkg -1 ), suggesting possible contamination or illegal use of that antibiotic. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Design, implementation and multisite evaluation of a system suitability protocol for the quantitative assessment of instrument performance in liquid chromatography-multiple reaction monitoring-MS (LC-MRM-MS).

    PubMed

    Abbatiello, Susan E; Mani, D R; Schilling, Birgit; Maclean, Brendan; Zimmerman, Lisa J; Feng, Xingdong; Cusack, Michael P; Sedransk, Nell; Hall, Steven C; Addona, Terri; Allen, Simon; Dodder, Nathan G; Ghosh, Mousumi; Held, Jason M; Hedrick, Victoria; Inerowicz, H Dorota; Jackson, Angela; Keshishian, Hasmik; Kim, Jong Won; Lyssand, John S; Riley, C Paige; Rudnick, Paul; Sadowski, Pawel; Shaddox, Kent; Smith, Derek; Tomazela, Daniela; Wahlander, Asa; Waldemarson, Sofia; Whitwell, Corbin A; You, Jinsam; Zhang, Shucha; Kinsinger, Christopher R; Mesri, Mehdi; Rodriguez, Henry; Borchers, Christoph H; Buck, Charles; Fisher, Susan J; Gibson, Bradford W; Liebler, Daniel; Maccoss, Michael; Neubert, Thomas A; Paulovich, Amanda; Regnier, Fred; Skates, Steven J; Tempst, Paul; Wang, Mu; Carr, Steven A

    2013-09-01

    Multiple reaction monitoring (MRM) mass spectrometry coupled with stable isotope dilution (SID) and liquid chromatography (LC) is increasingly used in biological and clinical studies for precise and reproducible quantification of peptides and proteins in complex sample matrices. Robust LC-SID-MRM-MS-based assays that can be replicated across laboratories and ultimately in clinical laboratory settings require standardized protocols to demonstrate that the analysis platforms are performing adequately. We developed a system suitability protocol (SSP), which employs a predigested mixture of six proteins, to facilitate performance evaluation of LC-SID-MRM-MS instrument platforms, configured with nanoflow-LC systems interfaced to triple quadrupole mass spectrometers. The SSP was designed for use with low multiplex analyses as well as high multiplex approaches when software-driven scheduling of data acquisition is required. Performance was assessed by monitoring of a range of chromatographic and mass spectrometric metrics including peak width, chromatographic resolution, peak capacity, and the variability in peak area and analyte retention time (RT) stability. The SSP, which was evaluated in 11 laboratories on a total of 15 different instruments, enabled early diagnoses of LC and MS anomalies that indicated suboptimal LC-MRM-MS performance. The observed range in variation of each of the metrics scrutinized serves to define the criteria for optimized LC-SID-MRM-MS platforms for routine use, with pass/fail criteria for system suitability performance measures defined as peak area coefficient of variation <0.15, peak width coefficient of variation <0.15, standard deviation of RT <0.15 min (9 s), and the RT drift <0.5min (30 s). The deleterious effect of a marginally performing LC-SID-MRM-MS system on the limit of quantification (LOQ) in targeted quantitative assays illustrates the use and need for a SSP to establish robust and reliable system performance. Use of a SSP helps

  20. Design, Implementation and Multisite Evaluation of a System Suitability Protocol for the Quantitative Assessment of Instrument Performance in Liquid Chromatography-Multiple Reaction Monitoring-MS (LC-MRM-MS)*

    PubMed Central

    Abbatiello, Susan E.; Mani, D. R.; Schilling, Birgit; MacLean, Brendan; Zimmerman, Lisa J.; Feng, Xingdong; Cusack, Michael P.; Sedransk, Nell; Hall, Steven C.; Addona, Terri; Allen, Simon; Dodder, Nathan G.; Ghosh, Mousumi; Held, Jason M.; Hedrick, Victoria; Inerowicz, H. Dorota; Jackson, Angela; Keshishian, Hasmik; Kim, Jong Won; Lyssand, John S.; Riley, C. Paige; Rudnick, Paul; Sadowski, Pawel; Shaddox, Kent; Smith, Derek; Tomazela, Daniela; Wahlander, Asa; Waldemarson, Sofia; Whitwell, Corbin A.; You, Jinsam; Zhang, Shucha; Kinsinger, Christopher R.; Mesri, Mehdi; Rodriguez, Henry; Borchers, Christoph H.; Buck, Charles; Fisher, Susan J.; Gibson, Bradford W.; Liebler, Daniel; MacCoss, Michael; Neubert, Thomas A.; Paulovich, Amanda; Regnier, Fred; Skates, Steven J.; Tempst, Paul; Wang, Mu; Carr, Steven A.

    2013-01-01

    Multiple reaction monitoring (MRM) mass spectrometry coupled with stable isotope dilution (SID) and liquid chromatography (LC) is increasingly used in biological and clinical studies for precise and reproducible quantification of peptides and proteins in complex sample matrices. Robust LC-SID-MRM-MS-based assays that can be replicated across laboratories and ultimately in clinical laboratory settings require standardized protocols to demonstrate that the analysis platforms are performing adequately. We developed a system suitability protocol (SSP), which employs a predigested mixture of six proteins, to facilitate performance evaluation of LC-SID-MRM-MS instrument platforms, configured with nanoflow-LC systems interfaced to triple quadrupole mass spectrometers. The SSP was designed for use with low multiplex analyses as well as high multiplex approaches when software-driven scheduling of data acquisition is required. Performance was assessed by monitoring of a range of chromatographic and mass spectrometric metrics including peak width, chromatographic resolution, peak capacity, and the variability in peak area and analyte retention time (RT) stability. The SSP, which was evaluated in 11 laboratories on a total of 15 different instruments, enabled early diagnoses of LC and MS anomalies that indicated suboptimal LC-MRM-MS performance. The observed range in variation of each of the metrics scrutinized serves to define the criteria for optimized LC-SID-MRM-MS platforms for routine use, with pass/fail criteria for system suitability performance measures defined as peak area coefficient of variation <0.15, peak width coefficient of variation <0.15, standard deviation of RT <0.15 min (9 s), and the RT drift <0.5min (30 s). The deleterious effect of a marginally performing LC-SID-MRM-MS system on the limit of quantification (LOQ) in targeted quantitative assays illustrates the use and need for a SSP to establish robust and reliable system performance. Use of a SSP helps

  1. BatMass: a Java Software Platform for LC-MS Data Visualization in Proteomics and Metabolomics.

    PubMed

    Avtonomov, Dmitry M; Raskind, Alexander; Nesvizhskii, Alexey I

    2016-08-05

    Mass spectrometry (MS) coupled to liquid chromatography (LC) is a commonly used technique in metabolomic and proteomic research. As the size and complexity of LC-MS-based experiments grow, it becomes increasingly more difficult to perform quality control of both raw data and processing results. In a practical setting, quality control steps for raw LC-MS data are often overlooked, and assessment of an experiment's success is based on some derived metrics such as "the number of identified compounds". The human brain interprets visual data much better than plain text, hence the saying "a picture is worth a thousand words". Here, we present the BatMass software package, which allows for performing quick quality control of raw LC-MS data through its fast visualization capabilities. It also serves as a testbed for developers of LC-MS data processing algorithms by providing a data access library for open mass spectrometry file formats and a means of visually mapping processing results back to the original data. We illustrate the utility of BatMass with several use cases of quality control and data exploration.

  2. BatMass: a Java software platform for LC/MS data visualization in proteomics and metabolomics

    PubMed Central

    Avtonomov, Dmitry; Raskind, Alexander; Nesvizhskii, Alexey I.

    2017-01-01

    Mass spectrometry (MS) coupled to liquid chromatography (LC) is a commonly used technique in metabolomic and proteomic research. As the size and complexity of LC/MS based experiments grow, it becomes increasingly more difficult to perform quality control of both raw data and processing results. In a practical setting, quality control steps for raw LC/MS data are often overlooked and assessment of an experiment's success is based on some derived metrics such as “the number of identified compounds”. Human brain interprets visual data much better than plain text, hence the saying “a picture is worth a thousand words”. Here we present BatMass software package which allows to perform quick quality control of raw LC/MS data through its fast visualization capabilities. It also serves as a testbed for developers of LC/MS data processing algorithms by providing a data access library for open mass spectrometry file formats and a means of visually mapping processing results back to the original data. We illustrate the utility of BatMass with several use cases of quality control and data exploration. PMID:27306858

  3. Intact stable isotope labeled plasma proteins from the SILAC-labeled HepG2 secretome.

    PubMed

    Mangrum, John B; Martin, Erika J; Brophy, Donald F; Hawkridge, Adam M

    2015-09-01

    The plasma proteome remains an attractive biospecimen for MS-based biomarker discovery studies. The success of these efforts relies on the continued development of quantitative MS-based proteomics approaches. Herein we report the use of the SILAC-labeled HepG2 secretome as a source for stable isotope labeled plasma proteins for quantitative LC-MS/MS measurements. The HepG2 liver cancer cell line secretes the major plasma proteins including serum albumin, apolipoproteins, protease inhibitors, coagulation factors, and transporters that represent some of the most abundant proteins in plasma. The SILAC-labeled HepG2 secretome was collected, spiked into human plasma (1:1 total protein), and then processed for LC-MS/MS analysis. A total of 62 and 56 plasma proteins were quantified (heavy:light (H/L) peptide pairs) from undepleted and depleted (serum albumin and IgG), respectively, with log2 H/L = ± 6. Major plasma proteins quantified included albumin, apolipoproteins (e.g., APOA1, APOA2, APOA4, APOB, APOC3, APOE, APOH, and APOM), protease inhibitors (e.g., A2M and SERPINs), coagulation factors (e.g., Factor V, Factor X, fibrinogen), and transport proteins (e.g., TTR). The average log2 H/L values for shared plasma proteins in both undepleted and depleted plasma samples were 0.43 and 0.44, respectively. This work further expands the SILAC strategy into MS-based biomarker discovery of clinical biospecimens. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. A method for the determination of acrylamide in bakery products using ion trap LC-ESI-MS/MS.

    PubMed

    Claus, Achim; Weisz, Georg M; Kammerer, Dietmar R; Carle, Reinhold; Schieber, Andreas

    2005-10-01

    Acrylamide levels of bakery products, e. g., bread and bread rolls, are usually below 100 microg/kg , often even below 50 microg/kg. Therefore, usual analytical methods which have an LOQ greater, not dbl equals 25 microg/kg are not sensitive enough for detailed investigations on acrylamide formation within these commodities. An improved method for trace level determination of acrylamide in bakery products was developed using ion trap LC-ESI-MS/MS. Samples were divided into crumbs and crusts to achieve an initial concentration by removing the crumbs since these are devoid of acrylamide. After sample extraction and clean-up using multimode SPE cartridges, further analyte enrichment was accomplished by solid-phase-supported liquid-liquid extraction with ethyl acetate prior to LC-MS/MS analysis. The method was evaluated using bread, bread rolls, alkali-baked bread rolls, and toast. LOQ was calculated from the confidence interval of the calibration curve and found to be 1.7 ng/mL, corresponding to 17 microg/kg of product. When crumbs and crusts were separated, an LOQ of 10.2 microg/kg of bakery product could be obtained. As demonstrated in preliminary comparative analyses, accuracy of the method met the requirements for determination of trace level acrylamide formation in bakery products. Mean recovery was 102.4% (CV 4.5%), intermediate reproducibility revealed a CV of 2.1%, and a repeatability of CV 6.0%.

  5. A LC-MS method allowing the analysis of HMX and RDX present at the picogram level in natural aqueous samples without a concentration step.

    PubMed

    Vigneau, Olivier; Machuron-Mandard, Xavier

    2009-03-15

    The introduction of chloroform into the nebulising gas of a LC/MS electrospray interface (ESI), in a perfectly controlled way, leads to the formation of intense adducts ([M+Cl](-)) when a mobile phase containing HMX (1,3,5,7-tetranitro-1,3,5,7-tetrazacyclooctane or octogen) and RDX (1,3,5-trintro-1,3,5-triazacyclohexane or hexogen) is eluted. This LC/MS method allows the direct analysis of aqueous samples containing HMX and RDX at the pictogram level without a concentration step. The method is used to determine HMX and RDX concentrations in ground water samples from a military site.

  6. Simultaneous determination of centchroman and tamoxifen along with their metabolites in rat plasma using LC-MS/MS.

    PubMed

    Rama Raju, Kanumuri Siva; Taneja, Isha; Singh, Sheelendra Pratap; Tripathi, Amit; Mishra, Durga Prasad; Hussain, K Mahaboob; Gayen, Jiaur Rahman; Singh, Shio Kumar; Wahajuddin, Muhammad

    2015-01-01

    Tamoxifen and centchroman are two non-steroidal, selective estrogen receptors modulators, intended for long term therapy in the woman. Because of their wide spread use, there is a possibility of co-prescription of these agents. We studied the probable pharmacokinetic interaction between these agents in breast cancer model rats. A simple, sensitive and rapid LC-ESI-MS/MS method was developed and validated for the simultaneous determination of tamoxifen, centchroman and their active metabolites. The method was linear over a range of 0.2-200 ng/ml. All validation parameters met the acceptance criteria according to regulatory guidelines. LC-MS/MS method for determination of tamoxifen, centchroman and their metabolites was developed and validated. Results show the potential of drug-drug interaction upon co-administration these two marketed drugs.

  7. High-Throughput Analytical Techniques for the Determination of the Residues of 653 Multiclass Pesticides and Chemical Pollutants in Tea, Part VII: A GC-MS, GC-MS/MS, and LC-MS/MS Study of the Degradation Profiles of Pesticide Residues in Green Tea.

    PubMed

    Chang, Qiao-Ying; Pang, Guo-Fang; Fan, Chun-Lin; Chen, Hui; Yang, Fang; Li, Jie; Wen, Bi-Fang

    2016-11-01

    GC-MS, GC-tandem MS (MS/MS), and LC-MS/MS were used to mathematically define the degradation profiles of pesticide residues in two field trials. Nineteen pesticides were studied in the first field trial and 11 in the second. The results of the field trials demonstrated that the degradation profiles of pesticide residues in green tea can be described with power functions to successfully estimate the amount of time, following pesticide application, pesticide residues appearing in tea in concentrations at and/or above the maximum residue limit (MRL) decrease to concentrations below the MRL. Stability tests on green tea samples stored at room temperature were conducted to determine whether pesticide-incurred green tea samples prepared according to the method used in the field trials would be suitable for the preparation of reference standards for laboratory-proficiency testing trials. This paper reports the results of a GC-MS, GC-MS/MS, and LC-MS/MS study, as well as the suitability of the samples prepared under these conditions for use as pesticide reference standards in tea analysis.

  8. LC-MS characterization of constituents of mesquite flour

    USDA-ARS?s Scientific Manuscript database

    Using an LC-MS method in conjunction with two complementary types of chromatographic retention modes—namely reversed phase and aqueous normal phase (ANP)—various compounds present in mesquite flour extracts were identified. Because of the diverse types of chemical constituents found in such natural ...

  9. Simultaneous Quantitation of Atenolol, Metoprolol, and Propranolol in Biological Matrices Via LC/MS

    DTIC Science & Technology

    2005-05-01

    Simultaneous Quantitation of Atenolol, Metoprolol , and Propranolol in Biological Matrices Via LC/MS Robert D. Johnson Russell J. Lewis Civil...authorized 1 SIMULTANEOUS QUANTITATION OF ATENOLOL, METOPROLOL , AND PROPRANOLOL IN BIOLOGICAL MATRICES VIA LC/MS INTRODUCTION The Federal Aviation...detect beta-blocker compounds such as atenolol, metoprolol , or propranolol in the submitted biological samples. In forensic toxicol- ogy laboratories

  10. Development of Immunocapture-LC/MS Assay for Simultaneous ADA Isotyping and Semiquantitation

    PubMed Central

    2016-01-01

    Therapeutic proteins and peptides have potential to elicit immune responses resulting in anti-drug antibodies that can pose problems for both patient safety and product efficacy. During drug development immunogenicity is usually examined by risk-based approach along with specific strategies for developing “fit-for-purpose” bioanalytical approaches. Enzyme-linked immunosorbent assays and electrochemiluminescence immunoassays are the most widely used platform for ADA detection due to their high sensitivity and throughput. During the past decade, LC/MS has emerged as a promising technology for quantitation of biotherapeutics and protein biomarkers in biological matrices, mainly owing to its high specificity, selectivity, multiplexing, and wide dynamic range. In fully taking these advantages, we describe here an immunocapture-LC/MS methodology for simultaneous isotyping and semiquantitation of ADA in human plasma. Briefly, ADA and/or drug-ADA complex is captured by biotinylated drug or anti-drug Ab, immobilized on streptavidin magnetic beads, and separated from human plasma by a magnet. ADA is then released from the beads and subjected to trypsin digestion followed by LC/MS detection of specific universal peptides for each ADA isotype. The LC/MS data are analyzed using cut-point and calibration curve. The proof-of-concept of this methodology is demonstrated by detecting preexisting ADA in human plasma. PMID:27034966

  11. Development of Immunocapture-LC/MS Assay for Simultaneous ADA Isotyping and Semiquantitation.

    PubMed

    Chen, Lin-Zhi; Roos, David; Philip, Elsy

    2016-01-01

    Therapeutic proteins and peptides have potential to elicit immune responses resulting in anti-drug antibodies that can pose problems for both patient safety and product efficacy. During drug development immunogenicity is usually examined by risk-based approach along with specific strategies for developing "fit-for-purpose" bioanalytical approaches. Enzyme-linked immunosorbent assays and electrochemiluminescence immunoassays are the most widely used platform for ADA detection due to their high sensitivity and throughput. During the past decade, LC/MS has emerged as a promising technology for quantitation of biotherapeutics and protein biomarkers in biological matrices, mainly owing to its high specificity, selectivity, multiplexing, and wide dynamic range. In fully taking these advantages, we describe here an immunocapture-LC/MS methodology for simultaneous isotyping and semiquantitation of ADA in human plasma. Briefly, ADA and/or drug-ADA complex is captured by biotinylated drug or anti-drug Ab, immobilized on streptavidin magnetic beads, and separated from human plasma by a magnet. ADA is then released from the beads and subjected to trypsin digestion followed by LC/MS detection of specific universal peptides for each ADA isotype. The LC/MS data are analyzed using cut-point and calibration curve. The proof-of-concept of this methodology is demonstrated by detecting preexisting ADA in human plasma.

  12. High-temperature LC-MS/MS of permethylated glycans derived from glycoproteins.

    PubMed

    Zhou, Shiyue; Hu, Yunli; Mechref, Yehia

    2016-06-01

    Various glycomic analysis methods have been developed due to the essential roles of glycans in biological processes as well as the potential application of glycomics in biomarker discovery in many diseases. Permethylation is currently considered to be one of the most common derivatization methods in MS-based glycomic analysis. Permethylation not only improves ionization efficiency and stability of sialylated glycans in positive mode but also allows for enhanced separation performance on reversed-phase liquid chromatography (RPLC). Recently, RPLC-MS analysis of permethylated glycans exhibited excellent performance in sensitivity and reproducibility and became a widely-applied comprehensive strategy in glycomics. However, separating permethylated glycans by RPLC always suffers from peak broadening for high-molecular-weight branched glycans, which probably due to the low exchange rate between the stationary phase and mobile phase limited by intermolecular interactions of the methyl groups associated with the branching of the glycan structures. In this study, we employed high separation temperature conditions for RPLC of permethylated glycans, thus achieving enhanced peak capacity, improving peak shape, and enhancing separation efficiency. Additionally, partial isomeric separation were observed in RPLC of permethylated glycans at high-temperature. Mathematical processing of the correlation between retention time and molecular weight also revealed the advantage of high-temperature LC method for both manual and automatic glycan identification. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Quantification of Soluble Sugars and Sugar Alcohols by LC-MS/MS.

    PubMed

    Feil, Regina; Lunn, John Edward

    2018-01-01

    Sugars are simple carbohydrates composed primarily of carbon, hydrogen, and oxygen. They play a central role in metabolism as sources of energy and as building blocks for synthesis of structural and nonstructural polymers. Many different techniques have been used to measure sugars, including refractometry, colorimetric and enzymatic assays, gas chromatography, high-performance liquid chromatography, and nuclear magnetic resonance spectroscopy. In this chapter we describe a method that combines an initial separation of sugars by high-performance anion-exchange chromatography (HPAEC) with detection and quantification by tandem mass spectrometry (MS/MS). This combination of techniques provides exquisite specificity, allowing measurement of a diverse range of high- and low-abundance sugars in biological samples. This method can also be used for isotopomer analysis in stable-isotope labeling experiments to measure metabolic fluxes.

  14. Characterization of Stevia leaves by LC-QTOF MS/MS analysis of polar and non-polar extracts.

    PubMed

    Molina-Calle, M; Priego-Capote, F; Luque de Castro, M D

    2017-03-15

    Stevia is currently a well-known plant thanks to its sweeting power. Numerous studies that elucidate its composition were exclusively focused on determination of steviol and its glycosides. Untargeted analysis was applied to obtain a profile of main compounds present in extracts from Stevia (Stevia rebaudiana Bertoni) leaves using LC-MS in high resolution mode with a quadrupole-time of flight analyzer. Eighty-nine compounds were tentatively identified and classified into different families: flavonoids; quinic and caffeic acids and derivatives; diterpenoids (including steviol and glycosides); sesquiterpenoids; amino acids and derivatives; fatty amides and derivatives; fatty acids and derivatives; oligosaccharides; glycerolipids; purines; and retinoids. New steviol glycosides were tentatively identified and their possible structures proposed. Other compounds were tentatively identified in Stevia for the first time, such as fatty acid amides. These results reveal the wide range of compounds present in Stevia, which could be responsible for the nutraceutical effects ascribed to their leaves. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Gaussian and linear deconvolution of LC-MS/MS chromatograms of the eight aminobutyric acid isomers

    PubMed Central

    Vemula, Harika; Kitase, Yukiko; Ayon, Navid J.; Bonewald, Lynda; Gutheil, William G.

    2016-01-01

    Isomeric molecules present a challenge for analytical resolution and quantification, even with MS-based detection. The eight-aminobutyric acid (ABA) isomers are of interest for their various biological activities, particularly γ-aminobutyric acid (GABA) and the d- and l-isomers of β-aminoisobutyric acid (β-AIBA; BAIBA). This study aimed to investigate LC-MS/MS-based resolution of these ABA isomers as their Marfey's (Mar) reagent derivatives. HPLC was able to separate three Mar-ABA isomers l-β-ABA (l-BABA), and l- and d-α-ABA (AABA) completely, with three isomers (GABA, and d/l-BAIBA) in one chromatographic cluster, and two isomers (α-AIBA (AAIBA) and d-BABA) in a second cluster. Partially separated cluster components were deconvoluted using Gaussian peak fitting except for GABA and d-BAIBA. MS/MS detection of Marfey's derivatized ABA isomers provided six MS/MS fragments, with substantially different intensity profiles between structural isomers. This allowed linear deconvolution of ABA isomer peaks. Combining HPLC separation with linear and Gaussian deconvolution allowed resolution of all eight ABA isomers. Application to human serum found a substantial level of l-AABA (13 μM), an intermediate level of l-BAIBA (0.8 μM), and low but detectable levels (<0.2 μM) of GABA, l-BABA, AAIBA, d-BAIBA, and d-AABA. This approach should be useful for LC-MS/MS deconvolution of other challenging groups of isomeric molecules. PMID:27771391

  16. Validation approach for a fast and simple targeted screening method for 75 antibiotics in meat and aquaculture products using LC-MS/MS.

    PubMed

    Dubreil, Estelle; Gautier, Sophie; Fourmond, Marie-Pierre; Bessiral, Mélaine; Gaugain, Murielle; Verdon, Eric; Pessel, Dominique

    2017-04-01

    An approach is described to validate a fast and simple targeted screening method for antibiotic analysis in meat and aquaculture products by LC-MS/MS. The strategy of validation was applied for a panel of 75 antibiotics belonging to different families, i.e., penicillins, cephalosporins, sulfonamides, macrolides, quinolones and phenicols. The samples were extracted once with acetonitrile, concentrated by evaporation and injected into the LC-MS/MS system. The approach chosen for the validation was based on the Community Reference Laboratory (CRL) guidelines for the validation of screening qualitative methods. The aim of the validation was to prove sufficient sensitivity of the method to detect all the targeted antibiotics at the level of interest, generally the maximum residue limit (MRL). A robustness study was also performed to test the influence of different factors. The validation showed that the method is valid to detect and identify 73 antibiotics of the 75 antibiotics studied in meat and aquaculture products at the validation levels.

  17. Fluorescence-labeled methylation-sensitive amplified fragment length polymorphism (FL-MS-AFLP) analysis for quantitative determination of DNA methylation and demethylation status.

    PubMed

    Kageyama, Shinji; Shinmura, Kazuya; Yamamoto, Hiroko; Goto, Masanori; Suzuki, Koichi; Tanioka, Fumihiko; Tsuneyoshi, Toshihiro; Sugimura, Haruhiko

    2008-04-01

    The PCR-based DNA fingerprinting method called the methylation-sensitive amplified fragment length polymorphism (MS-AFLP) analysis is used for genome-wide scanning of methylation status. In this study, we developed a method of fluorescence-labeled MS-AFLP (FL-MS-AFLP) analysis by applying a fluorescence-labeled primer and fluorescence-detecting electrophoresis apparatus to the existing method of MS-AFLP analysis. The FL-MS-AFLP analysis enables quantitative evaluation of more than 350 random CpG loci per run. It was shown to allow evaluation of the differences in methylation level of blood DNA of gastric cancer patients and evaluation of hypermethylation and hypomethylation in DNA from gastric cancer tissue in comparison with adjacent non-cancerous tissue.

  18. Characterization of Glycan Structures of Chondroitin Sulfate-Glycopeptides Facilitated by Sodium Ion-Pairing and Positive Mode LC-MS/MS

    NASA Astrophysics Data System (ADS)

    Nilsson, Jonas; Noborn, Fredrik; Gomez Toledo, Alejandro; Nasir, Waqas; Sihlbom, Carina; Larson, Göran

    2017-02-01

    Purification and liquid chromatography-tandem mass spectrometry (LC-MS/MS) characterization of glycopeptides, originating from protease digests of glycoproteins, enables site-specific analysis of protein N- and O-glycosylations. We have described a protocol to enrich, hydrolyze by chondroitinase ABC, and characterize chondroitin sulfate-containing glycopeptides (CS-glycopeptides) using positive mode LC-MS/MS. The CS-glycopeptides, originating from the Bikunin proteoglycan of human urine samples, had ΔHexAGalNAcGlcAGalGalXyl- O-Ser hexasaccharide structure and were further substituted with 0-3 sulfate and 0-1 phosphate groups. However, it was not possible to exactly pinpoint sulfate attachment residues, for protonated precursors, due to extensive fragmentation of sulfate groups using high-energy collision induced dissociation (HCD). To circumvent the well-recognized sulfate instability, we now introduced Na+ ions to form sodiated precursors, which protected sulfate groups from decomposition and facilitated the assignment of sulfate modifications. Sulfate groups were pinpointed to both Gal residues and to the GalNAc of the hexasaccharide structure. The intensities of protonated and sodiated saccharide oxonium ions were very prominent in the HCD-MS2 spectra, which provided complementary structural analysis of sulfate substituents of CS-glycopeptides. We have demonstrated a considerable heterogeneity of the bikunin CS linkage region. The realization of these structural variants should be beneficial in studies aimed at investigating the importance of the CS linkage region with regards to the biosynthesis of CS and potential interactions to CS binding proteins. Also, the combined use of protonated and sodiated precursors for positive mode HCD fragmentation analysis will likely become useful for additional classes of sulfated glycopeptides.

  19. An automated online turboflow cleanup LC/MS/MS method for the determination of 11 plasticizers in beverages and milk.

    PubMed

    Ates, Ebru; Mittendorf, Klaus; Senyuva, Hamide

    2013-01-01

    An automated sample preparation technique involving cleanup and analytical separation in a single operation using an online coupled TurboFlow (RP-LC system) is reported. This method eliminates time-consuming sample preparation steps that can be potential sources for cross-contamination in the analysis of plasticizers. Using TurboFlow chromatography, liquid samples were injected directly into the automated system without previous extraction or cleanup. Special cleanup columns enabled specific binding of target compounds; higher MW compounds, i.e., fats and proteins, and other matrix interferences with different chemical properties were removed to waste, prior to LC/MS/MS. Systematic stepwise method development using this new technology in the food safety area is described. Selection of optimum columns and mobile phases for loading onto the cleanup column followed by transfer onto the analytical column and MS detection are critical method parameters. The method was optimized for the assay of 10 phthalates (dimethyl, diethyl, dipropyl, butyl benzyl, diisobutyl, dicyclohexyl, dihexyl, diethylhexyl, diisononyl, and diisododecyl) and one adipate (diethylhexyl) in beverages and milk.

  20. Systematic Assessment of Seven Solvent and Solid-Phase Extraction Methods for Metabolomics Analysis of Human Plasma by LC-MS

    PubMed Central

    Sitnikov, Dmitri G.; Monnin, Cian S.; Vuckovic, Dajana

    2016-01-01

    The comparison of extraction methods for global metabolomics is usually executed in biofluids only and focuses on metabolite coverage and method repeatability. This limits our detailed understanding of extraction parameters such as recovery and matrix effects and prevents side-by-side comparison of different sample preparation strategies. To address this gap in knowledge, seven solvent-based and solid-phase extraction methods were systematically evaluated using standard analytes spiked into both buffer and human plasma. We compared recovery, coverage, repeatability, matrix effects, selectivity and orthogonality of all methods tested for non-lipid metabolome in combination with reversed-phased and mixed-mode liquid chromatography mass spectrometry analysis (LC-MS). Our results confirmed wide selectivity and excellent precision of solvent precipitations, but revealed their high susceptibility to matrix effects. The use of all seven methods showed high overlap and redundancy which resulted in metabolite coverage increases of 34–80% depending on LC-MS method employed as compared to the best single extraction protocol (methanol/ethanol precipitation) despite 7x increase in MS analysis time and sample consumption. The most orthogonal methods to methanol-based precipitation were ion-exchange solid-phase extraction and liquid-liquid extraction using methyl-tertbutyl ether. Our results help facilitate rational design and selection of sample preparation methods and internal standards for global metabolomics. PMID:28000704

  1. RP-UHPLC-UV-ESI-MS/MS analysis of LPMO generated C4-oxidized gluco-oligosaccharides after non-reductive labeling with 2-aminobenzamide.

    PubMed

    Frommhagen, Matthias; van Erven, Gijs; Sanders, Mark; van Berkel, Willem J H; Kabel, Mirjam A; Gruppen, Harry

    2017-08-07

    Lytic polysaccharide monooxygenases (LPMOs) are able to cleave recalcitrant polysaccharides, such as cellulose, by oxidizing the C1 and/or C4 atoms. The analysis of the resulting products requires a variety of analytical techniques. Up to now, these techniques mainly focused on the identification of non-oxidized and C1-oxidized oligosaccharides. The analysis of C4-oxidized gluco-oligosaccharides is mostly performed by using high pressure anion exchange chromatography (HPAEC). However, the alkaline conditions used during HPAEC analysis lead to tautomerization of C4-oxidized gluco-oligosaccharides, which limits the use of this technique. Here, we describe the use of reverse phase-ultra high performance liquid chromatography (RP-UHPLC) in combination with non-reductive 2-aminobenzamide (2-AB) labeling. Non-reductive 2-AB labeling enabled separation of C4-oxidized gluco-oligosaccharides from their non-oxidized counterparts. Moreover, RP-UHPLC does not require buffered mobile phases, which reduce mass spectrometry (MS) sensitivity. The latter is seen as an advantage over other techniques such as hydrophilic interaction liquid chromatography and porous graphitized carbon coupled to MS. RP-UHPLC coupled to UV detection and mass spectrometry allowed the identification of both labeled non-oxidized and C4-oxidized oligosaccharides. Non-reductive labeling kept the ketone at the C4-position of LPMO oxidized oligosaccharides intact, while selective reducing agents such as sodium triacetoxyborohydride (STAB) reduced this ketone group. Our results show that RP-UHPLC-UV-ESI-MS in combination with non-reductively 2-AB labeling is a suitable technique for the separation and identification of LPMO-generated C4-oxidized gluco-oligosaccharides. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Direct analysis of [6,6-(2)H2]glucose and [U-(13)C6]glucose dry blood spot enrichments by LC-MS/MS.

    PubMed

    Coelho, Margarida; Mendes, Vera M; Lima, Inês S; Martins, Fátima O; Fernandes, Ana B; Macedo, M Paula; Jones, John G; Manadas, Bruno

    2016-06-01

    A liquid chromatography tandem mass spectrometry (LC-MS/MS) using multiple reaction monitoring (MRM) in a triple-quadrupole scan mode was developed and comprehensively validated for the determination of [6,6-(2)H2]glucose and [U-(13)C6]glucose enrichments from dried blood spots (DBS) without prior derivatization. The method is demonstrated with dried blood spots obtained from rats administered with a primed-constant infusion of [U-(13)C6]glucose and an oral glucose load enriched with [6,6-(2)H2]glucose. The sensitivity is sufficient for analysis of the equivalent to <5μL of blood and the overall method was accurate and precise for the determination of DBS isotopic enrichments. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Reassessment of the Access Testosterone chemiluminescence assay and comparison with LC-MS method.

    PubMed

    Dittadi, Ruggero; Matteucci, Mara; Meneghetti, Elisa; Ndreu, Rudina

    2018-03-01

    To reassess the imprecision and Limit of Quantitation, to evaluate the cross-reaction with dehydroepiandrosterone-sulfate (DHEAS), the accuracy toward liquid chromatography-mass spectrometry (LC-MS) and the reference interval of the Access Testosterone method, performed by DxI immunoassay platform (Beckman Coulter). Imprecision was evaluated testing six pool samples assayed in 20 different run using two reagents lots. The cross-reaction with DHEAS was studied both by a displacement curve and by spiking DHEAS standard in two serum samples with known amount of testosterone. The comparison with LC-MS was evaluated by Passing-Bablock analysis in 21 routine serum samples and 19 control samples from an External Quality Assurance (EQA) scheme. The reference interval was verified by an indirect estimation on 2445 male and 2838 female outpatients. The imprecision study showed a coefficient of variation (CV) between 2.7% and 34.7% for serum pools from 16.3 and 0.27 nmol/L. The value of Limit of Quantitation at 20% CV was 0.53 nmol/L. The DHEAS showed a cross-reaction of 0.0074%. A comparison with LC-MS showed a trend toward a slight underestimation of immunoassay vs LC-MS (Passing-Bablock equations: DxI=-0.24+0.906 LCMS in serum samples and DxI=-0.299+0.981 LCMS in EQA samples). The verification of reference interval showed a 2.5th-97.5th percentile distribution of 6.6-24.3 nmol/L for male over 14 years and <0.5-2.78 nmol/L for female subjects, in accord with the reference intervals reported by the manufacturer. The Access Testosterone method could be considered an adequately reliable tool for the testosterone measurement. © 2017 Wiley Periodicals, Inc.

  4. Simultaneous Multiple MS Binding Assays Addressing D1 and D2 Dopamine Receptors.

    PubMed

    Schuller, Marion; Höfner, Georg; Wanner, Klaus T

    2017-10-09

    MS Binding Assays are a label-free alternative to radioligand binding assays. They provide basically the same capabilities as the latter, but use a non-labeled reporter ligand instead of a radioligand. In contrast to radioligand binding assays, MS Binding Assays offer-owing to the selectivity of mass spectrometric detection-the opportunity to monitor the binding of different reporter ligands at different targets simultaneously. The present study shows a proof of concept for this strategy as exemplified for MS Binding Assays selectively addressing D 1 and D 2 dopamine receptors in a single binding experiment. A highly sensitive, rapid and robust LC-ESI-MS/MS quantification method capable of quantifying both SCH23390 and raclopride, selectively addressing D 1 and D 2 receptors, respectively, was established and validated for this purpose. Based thereon, simultaneous saturation and competition experiments with SCH23390 and raclopride in the presence of both D 1 and D 2 receptors were performed and analyzed by LC-MS/MS within a single chromatographic cycle. The present study thus demonstrates the feasibility of this strategy and the high versatility of MS Binding Assays that appears to surpass that common for conventional radioligand binding assays. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Simultaneous screening of targeted and non-targeted contaminants using an LC-QTOF-MS system and automated MS/MS library searching.

    PubMed

    Herrera-Lopez, S; Hernando, M D; García-Calvo, E; Fernández-Alba, A R; Ulaszewska, M M

    2014-09-01

    Simultaneous high-resolution full-scan and tandem mass spectrometry (MS/MS) analysis using time of flight mass spectrometry brings an answer for increasing demand of retrospective and non-targeted data analysis. Such analysis combined with spectral library searching is a promising tool for targeted and untargeted screening of small molecules. Despite considerable extension of the panel of compounds of tandem mass spectral libraries, the heterogeneity of spectral data poses a major challenge against the effective usage of spectral libraries. Performance evaluation of available LC-MS/MS libraries will significantly increase credibility in the search results. The present work was aimed to evaluate fluctuation of MS/MS pattern, in the peak intensities distribution together with mass accuracy measurements, and in consequence, performance compliant with ion ratio and mass error criteria as principles in identification processes for targeted and untargeted contaminants at trace levels. Matrix effect and ultra-trace levels of concentration (from 50 ng l(-1) to 1000 ng l(-1) were evaluated as potential source of inaccuracy in the performance of spectral matching. Matrix-matched samples and real samples were screened for proof of applicability. By manual review of data and application of ion ratio and ppm error criteria, false negatives were obtained; this number diminished when in-house library was used, while with on-line MS/MS databases 100% of positive samples were found. In our experience, intensity of peaks across spectra was highly correlated to the concentration effect and matrix complexity. In turn, analysis of spectra acquired at trace concentrations and in different matrices results in better performance in providing correct and reliable identification. Copyright © 2014 John Wiley & Sons, Ltd.

  6. Identification of Forced Degradation Products of Itopride by LC-PDA and LC-MS.

    PubMed

    Joshi, Payal; Bhoir, Suvarna; Bhagwat, A M; Vishwanath, K; Jadhav, R K

    2011-05-01

    Degradation products of itopride formed under different forced conditions have been identified using LC-PDA and LC-MS techniques. Itopride was subjected to forced degradation under the conditions of hydrolysis, photolysis, oxidation, dry and wet heat, in accordance with the International Conference on Harmonization. The stress solutions were chromatographed on reversed phase C18 (250×4.6 mm, 5 μm) column with a mobile phase methanol:water (55:45, v/v) at a detection wavelength of 215 nm. Itopride degraded in acid, alkali and oxidative stress conditions. The stability indicating method was developed and validated. The degradation pathway of the drug to products II-VIII is proposed.

  7. Identification of Forced Degradation Products of Itopride by LC-PDA and LC-MS

    PubMed Central

    Joshi, Payal; Bhoir, Suvarna; Bhagwat, A. M.; Vishwanath, K.; Jadhav, R. K.

    2011-01-01

    Degradation products of itopride formed under different forced conditions have been identified using LC-PDA and LC-MS techniques. Itopride was subjected to forced degradation under the conditions of hydrolysis, photolysis, oxidation, dry and wet heat, in accordance with the International Conference on Harmonization. The stress solutions were chromatographed on reversed phase C18 (250×4.6 mm, 5 μm) column with a mobile phase methanol:water (55:45, v/v) at a detection wavelength of 215 nm. Itopride degraded in acid, alkali and oxidative stress conditions. The stability indicating method was developed and validated. The degradation pathway of the drug to products II-VIII is proposed. PMID:22457552

  8. Enantiomeric separation of metolachlor and its metabolites using LC-MS and CZE

    USGS Publications Warehouse

    Klein, C. John; Schneider, R.J.; Meyer, M.T.; Aga, D.S.

    2006-01-01

    The stereoisomers of metolachlor and its two polar metabolites [ethane sulfonic acid (ESA) and oxanilic acid (OXA)] were separated using liquid chromatography-mass spectrometry (LC-MS) and capillary zone electrophoresis (CZE), respectively. The separation of metolachlor enantiomers was achieved using a LC-MS equipped with a chiral stationary phase based on cellulose tris(3,5-dimethylphenyl carbamate) and an atmospheric pressure chemical ionization source operated under positive ion mode. The enantiomers of ESA and OXA were separated using CZE with gamma-cyclodextrin (??-CD) as chiral selector. Various CZE conditions were investigated to achieve the best resolution of the ESA and OXA enantiomers. The optimum background CZE electrolyte was found to consist of borate buffer (pH = 9) containing 20% methanol (v/v) and 2.5% ??-CD (w/v). Maximum resolution of ESA and OXA enantiomers was achieved using a capillary temperature of 15??C and applied voltage of 30 kV. The applicability of the LC-MS and CZE methods was demonstrated successfully on the enantiomeric analysis of metolachlor and its metabolites in samples from a soil and water degradation study that was set up to probe the stereoselectivity of metolachlor biodegradation. These techniques allow the enantiomeric ratios of the target analytes to be followed over time during the degradation process and thus will prove useful in determining the role of chirality in pesticide degradation and metabolite formation. ?? 2005 Elsevier Ltd. All rights reserved.

  9. Improved sensitivity of ochratoxin A analysis in coffee using high-performance liquid chromatography with hybrid triple quadrupole-linear ion trap mass spectrometry (LC-QqQLIT-MS/MS).

    PubMed

    Kokina, Aija; Pugajeva, Iveta; Bartkevics, Vadims

    2016-01-01

    A novel and sensitive method utilising high-performance liquid chromatography coupled to triple quadrupole-linear ion trap mass spectrometry (LC-QqQLIT-MS/MS) was developed in order to analyse the content of ochratoxin A (OTA) in coffee samples. The introduction of the triple-stage MS scanning mode (MS(3)) has been shown to increase greatly sensitivity and selectivity by eliminating the high chromatographic baseline caused by interference of complex coffee matrices. The analysis included the sample preparation procedure involving extraction of OTA using a methanol-water mixture and clean-up by immunoaffinity columns and detection using the MS(3) scanning mode of LC-QqQLIT-MS/MS. The proposed method offered a good linear correlation (r(2) > 0.998), excellent precision (RSD < 2.9%) and recovery (94%). The limit of quantification (LOQ) for coffee beans and espresso beverages was 0.010 and 0.003 µg kg(-1), respectively. The developed procedure was compared with traditional methods employing liquid chromatography coupled to fluorescent and tandem quadrupole detectors in conjunction with QuEChERS and solid-phase extraction. The proposed method was successfully applied to the determination of OTA in 15 samples of coffee beans and in 15 samples of espresso coffee beverages obtained from the Latvian market. OTA was found in 10 samples of coffee beans and in two samples of espresso in the ranges of 0.018-1.80 µg kg(-1) and 0.020-0.440 µg l(-1), respectively. No samples exceeded the maximum permitted level of OTA in the European Union (5.0 µg kg(-1)).

  10. New 3D-printed sorbent for extraction of steroids from human plasma preceding LC-MS analysis.

    PubMed

    Konieczna, Lucyna; Belka, Mariusz; Okońska, Magdalena; Pyszka, Magdalena; Bączek, Tomasz

    2018-04-13

    In recent years, there has been an increasing worldwide interest in the use of alternative sample preparation methods that are proceeded by separation techniques. Fused deposition modeling (FDM) is a 3D printing technique that is based the consecutive layering of softened/melted thermoplastic materials. In this study, a group of natural steroids and sexual hormones - namely, aldosterone, cortisol, β-estradiol, testosterone, dihydrotestosterone, and synthetic methyltestosterone and betamethasone - were separated and determined using an optimized high-performance liquid chromatography coupled to mass spectrometry (LC-MS) method in positive ionization mode. 3D-printed sorbents were selected as the pre-concentration technique because they are generally low cost, fast, and simple to make and automate. Furthermore, the use of 3D-printed sorbents helps to minimize potential errors due to their repeatability and reproducibility, and their ability to eliminate carry over by using one printed sorbent for a single extraction of steroids from biological matrices. The extraction procedure was optimized and the parameters influencing 3D-printed Layfomm 60 ® based sorbent and LC-MS were studied, including the type of extraction solvent used, sorption and desorption times, temperature, and the salting-out effect. To demonstrate this method's applicability for biological sample analysis, the SPME-LC-MS method was validated for its ability to simultaneously quantify endogenous steroids. This evaluation confirmed good linearity and an R 2 that was between 0.9970 and 0.9990. The recovery rates for human plasma samples were 86.34-93.6% for the studied steroids with intra- and inter-day RSDs of 1.44-7.42% and 1.44-9.46%, respectively. To our knowledge, this study is the first time that 3D-printed sorbents have been used to extract trace amounts of endogenous low-molecular-weight compounds, such as steroids, from biological samples, such as plasma. Copyright © 2018 Elsevier B.V. All

  11. Quantification of desoxyrhapontigenin (4-methoxyresveratrol) in rat plasma by LC-MS/MS: Application to pre-clinical pharmacokinetic study.

    PubMed

    Dai, Yu; Tan, Amanda Li Cheng; Chen, Huan; Ong, Pei Shi; Xiang, Xiaoqiang; Wu, Jinzhu; Lin, Hai-Shu

    2018-05-10

    Desoxyrhapontigenin (DRG, 4-methoxyresveratrol or trans-3,5-dihydroxy-4'-methoxystilbene) is a naturally occurring resveratrol (RES) derivative with a variety of biological activities. To facilitate its further medicinal exploration, a reliable LC-MS/MS method was developed and validated for the quantification of DRG in rat plasma using heavy isotope labelled RES as an internal standard. The ESI was operated in its negative ion mode while DRG and RES were determined by multiple reaction monitoring (MRM) using precursor-to-product ion transitions of m/z 241.1 → 180.8 and m/z 233.0 → 191.0, respectively. This LC-MS/MS method displayed excellent selectivity, sensitivity (LLOQ = 2.5 ng/ml), accuracy (both intra- and interday mean analytical recovery within 100 ± 15%) and precision (both intra- and interday CV < 15%). The mean matrix factors were all within 1.000 ± 0.150 with CV < 15%. The pharmacokinetic profiles of DRG were subsequently examined in Sprague-Dawley rats. Upon intravenous administration (4 or 10 mg/kg), DRG displayed very rapid clearance (Cl = 338 ± 66 or 275 ± 30 ml/min/kg) and short mean residence time (MRT = 12.9 ± 4.7 or 10.4 ± 0.5 min). After oral administration of DRG fully solubilized by 2-hydroxypropyl-β-cyclodextrin (HP-β-CD), the plasma profiles of DRG were highly erratic with a low absolute bioavailability (F < 9.83 ± 5.31%). When DRG was given at a higher dose (50 mg/kg) in suspension form, the F was increased to 24.1 ± 5.6%. The pharmacokinetic comparison among DRG, RES and some of its hydroxyl analogues stilbenes was performed. The information obtained from this study will facilitate further exploration on DRG as well as other RES derivatives. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. A novel mass spectrometry-based method for simultaneous determination of asymmetric and symmetric dimethylarginine, l-arginine and l-citrulline optimized for LC-MS-TOF and LC-MS/MS.

    PubMed

    Wiśniewski, Jerzy; Fleszar, Mariusz G; Piechowicz, Joanna; Krzystek-Korpacka, Małgorzata; Chachaj, Angelika; Szuba, Andrzej; Lorenc-Kukula, Katarzyna; Masłowski, Leszek; Witkiewicz, Wojciech; Gamian, Andrzej

    2017-11-01

    Nitric oxide (NO) is a regulatory molecule involved in many biological processes. NO is produced by nitric oxide synthase by conversion of l-arginine to l-citrulline. l-Arginine methylated derivatives, asymmetric and symmetric dimethylarginines (asymmetric dimethylarginine, ADMA, and symmetric dimethylarginine, SDMA), regulate l-arginine availability and the activity of nitric oxide synthase. As such, they have been frequently investigated as potential biomarkers in pathologies associated with dysfunctions in NO synthesis. Here, we present a new multistep analytical methodology based on liquid chromatography combined with mass spectrometry for the accurate identification of l-arginine, l-citrulline, ADMA and SDMA. Compounds are measured as stable 2,3,4,5,6-pentafluorobenzoyl chloride derivatives, which allows for simultaneous analysis of all compounds through chromatographic separation of ADMA and SDMA using a reverse-phase column. Serum aliquots (100 μL) were spiked with isotope-labeled internal standards and sodium carbonate buffer. The derivatization process was carried out at 25°C for 10 minu using pentafluorobenzoyl chloride as derivatization reagent. Calibration demonstrated good linearity (R 2  = 0.9966-0.9986) for all derivatized compounds. Good accuracy (94.67-99.91%) and precision (1.92-11.8%) were observed for the quality control samples. The applicability of the method was evaluated in a cohort of angiological patients and healthy volunteers. The method discerned significantly lower l-arginine and l-citrulline in angiologic patients. This robust and fast LC-ESI-MS method may be a useful tool in quantitative analysis of l-arginine, ADMA, SDMA and l-citrulline. Copyright © 2017 John Wiley & Sons, Ltd.

  13. Use of LC-MS/MS and Stable Isotopes to Differentiate Hydroxymethyl and Methyl DNA Adducts from Formaldehyde and Nitrosodimethylamine

    PubMed Central

    Lu, Kun; Craft, Sessaly; Nakamura, Jun; Moeller, Benjamin C.; Swenberg, James A.

    2012-01-01

    Formaldehyde is a known human and animal carcinogen that forms DNA adducts, and causes mutations. While there is widespread exposure to formaldehyde in the environment, formaldehyde is also an essential biochemical in all living cells. The presence of both endogenous and exogenous sources of formaldehyde makes it difficult to develop exposure-specific DNA biomarkers. Furthermore, chemicals such as nitrosodimethylamine form one mole of formaldehyde for every mole of methylating agent, raising questions about potential co-carcinogenesis. Formaldehyde-induced hydroxymethyl DNA adducts are not stable and need to be reduced to stable methyl adducts for detection, which adds another layer of complexity to identifying the origins of these adducts. In this study, highly sensitive mass spectrometry methods and isotope labeled compounds were used to differentiate between endogenous and exogenous hydroxymethyl and methyl DNA adducts. We demonstrate that N2-hydroxymethyl-dG is the primary DNA adduct formed in cells following formaldehyde exposure. In addition, we show that alkylating agents induce methyl adducts at N2-dG and N6-dA positions, which are identical to the reduced forms of hydroxymethyl adducts arising from formaldehyde. The use of highly sensitive LC-MS/MS and isotope labeled compounds for exposure solves these challenges and provides mechanistic insights on the formation and role of these DNA adducts. PMID:22148432

  14. A novel approach for quantitation of glucosylceramide in human dried blood spot using LC-MS/MS.

    PubMed

    Ji, Allena Ji; Wang, Haixing; Ziso-Qejvanaj, Enida; Zheng, Kefei; Chung, Lee Lee; Foley, Timothy; Chuang, Wei-Lien; Richards, Susan; Sung, Crystal

    2015-01-01

    Glucosylceramide, an efficacy biomarker for Gaucher Type 1 disease, exhibits poor solubility in polar solvents and whole blood which makes it difficult to prepare a homogenous blood standard. We developed a novel method using standard addition approach by spiking a small volume of analyte solution on the surface of prespotted dried blood spot. The whole spots were punched out for subsequent extraction and LC-MS/MS analysis. The assay performance met all validation acceptance criteria. Glucosylceramide concentrations in 50 paired plasma and dry blood spot samples obtained from Gaucher Type 1 patients were tested and the results demonstrated the feasibility of using the DBS method for clinical biomarker monitoring. The new approach greatly improves assay precision and accuracy.

  15. Determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis

    PubMed Central

    Liu, Ping; Qi, Chu-Bo; Zhu, Quan-Fei; Yuan, Bi-Feng; Feng, Yu-Qi

    2016-01-01

    Precursor ion scan and multiple reaction monitoring scan (MRM) are two typical scan modes in mass spectrometry analysis. Here, we developed a strategy by combining stable isotope labeling (IL) with liquid chromatography-mass spectrometry (LC-MS) under double precursor ion scan (DPI) and MRM for analysis of thiols in 5 types of human cancer urine. Firstly, the IL-LC-DPI-MS method was applied for non-targeted profiling of thiols from cancer samples. Compared to traditional full scan mode, the DPI method significantly improved identification selectivity and accuracy. 103 thiol candidates were discovered in all cancers and 6 thiols were identified by their standards. It is worth noting that pantetheine, for the first time, was identified in human urine. Secondly, the IL-LC-MRM-MS method was developed for relative quantification of thiols in cancers compared to healthy controls. All the MRM transitions of light and heavy labeled thiols were acquired from urines by using DPI method. Compared to DPI method, the sensitivity of MRM improved by 2.1–11.3 folds. In addition, the concentration of homocysteine, γ-glutamylcysteine and pantetheine enhanced more than two folds in cancer patients compared to healthy controls. Taken together, the method demonstrated to be a promising strategy for identification and comprehensive quantification of thiols in human urines. PMID:26888486

  16. Quantitative Metabolome Analysis Based on Chromatographic Peak Reconstruction in Chemical Isotope Labeling Liquid Chromatography Mass Spectrometry.

    PubMed

    Huan, Tao; Li, Liang

    2015-07-21

    Generating precise and accurate quantitative information on metabolomic changes in comparative samples is important for metabolomics research where technical variations in the metabolomic data should be minimized in order to reveal biological changes. We report a method and software program, IsoMS-Quant, for extracting quantitative information from a metabolomic data set generated by chemical isotope labeling (CIL) liquid chromatography mass spectrometry (LC-MS). Unlike previous work of relying on mass spectral peak ratio of the highest intensity peak pair to measure relative quantity difference of a differentially labeled metabolite, this new program reconstructs the chromatographic peaks of the light- and heavy-labeled metabolite pair and then calculates the ratio of their peak areas to represent the relative concentration difference in two comparative samples. Using chromatographic peaks to perform relative quantification is shown to be more precise and accurate. IsoMS-Quant is integrated with IsoMS for picking peak pairs and Zero-fill for retrieving missing peak pairs in the initial peak pairs table generated by IsoMS to form a complete tool for processing CIL LC-MS data. This program can be freely downloaded from the www.MyCompoundID.org web site for noncommercial use.

  17. Phenolic antioxidants (hydrolyzable tannins, flavonols, and anthocyanins) identified by LC-ESI-MS and MALDI-QIT-TOF MS from Rosa chinensis flowers.

    PubMed

    Cai, Yi-Zhong; Xing, Jie; Sun, Mei; Zhan, Zhao-Qi; Corke, Harold

    2005-12-28

    Rosa chinensis (Yuejihua) is a well-known ornamental plant, and its flowers are commonly used in traditional Chinese medicine. Methanolic crude extracts of dried R. chinensis flowers were used for simultaneous determination of phenolic constituents by liquid chromatography-mass spectrometry (LC-MS) and matrix-assisted laser desorption/ionization quadrupole ion trap time-of-flight mass spectrometry (MALDI-QIT-TOF MS). A total of 36 known and unknown phenolics were identified as hydrolyzable tannins, flavonols, and anthocyanins, mainly including gallotannins (mono-, di-, or trigalloylglucopyranosides), ellagitannins, quercetin, quercetin/kaempferol mono- and diglycosides, and cyanidin/pelargonidin diglycosides. MALDI-QIT-TOF MS was applied not only to verify most phenolics isolated and identified by LC-MS but also to tentatively identify two ellagitannins (rugosins B and C) not isolated and unidentified by LC-MS. This study is the first to demonstrate the rapid and successful use of MALDI-QIT-TOF MS and LC-MS to directly and simultaneously identify phenolics in the crude extracts of R. chinensis flowers without any purification. The antioxidant activity of the crude extracts from R. chinensis flowers was also measured with three assay methods. The results showed that the phenolic antioxidants from R. chinensis flowers exhibited very strong radical scavenging effect and antioxidant power. High levels of flavonols and hydrolyzable tannins might be important bioactive principles in the dried R. chinensis flowers.

  18. Surveillance of drug abuse in Hong Kong by hair analysis using LC-MS/MS.

    PubMed

    Leung, K Wing; Wong, Zack C F; Ho, Janet Y M; Yip, Ada W S; Cheung, Jerry K H; Ho, Karen K L; Duan, Ran; Tsim, Karl W K

    2018-06-01

    The aim of this study is to reveal the habits of drug abusers in hair samples from drug rehabilitation units in Hong Kong. With the application of liquid chromatography-tandem mass spectrometry (LC-MS/MS) technology, a total of 1771 hair samples were analyzed during the period of hair testing service (January 2012 to March 2016) provided to 14 drug rehabilitation units including non-governmental organizations (NGOs), rehabilitation centers, and medical clinics. Hair samples were analyzed for abused drugs and their metabolites simultaneously, including ketamine, norketamine, cocaine, benzoylecgonine, cocaethylene, norcocaine, codeine, MDMA, MDA, MDEA, amphetamine, methamphetamine, morphine, 6-acetylmorphine, phencyclidine, and methadone. The results showed that ketamine (77.2%), cocaine (21.3%), and methamphetamine (16.5%) were the frequently detected drugs among those drug abusers, which is consistent with the reported data. In addition, the usage of multiple drugs was also observed in the hair samples. About 29% of drug-positive samples were detected with multiple drug use. Our studies prove that our locally developed hair drug-testing method and service can be a valid tool to monitor the use of abused drugs, and which could facilitate rehabilitation program management. Copyright © 2017 John Wiley & Sons, Ltd.

  19. Label-free proteomics assisted by affinity enrichment for elucidating the chemical reactivity of the liver mitochondrial proteome toward adduction by the lipid electrophile 4-hydroxy-2-nonenal (HNE)

    NASA Astrophysics Data System (ADS)

    Maier, Claudia

    2016-03-01

    The analysis of oxidative stress-induced post-translational modifications remains challenging due to the chemical diversity of these modifications, the possibility of the presence of positional isomers and the low stoichiometry of the modified proteins present in a cell or tissue proteome. Alcoholic liver disease (ALD) is a multifactorial disease in which mitochondrial dysfunction and oxidative stress have been identified as being critically involved in the progression of the disease from steatosis to cirrhosis. Ethanol metabolism leads to increased levels of reactive oxygen species (ROS), glutathione depletion and lipid peroxidation. Posttranslational modification of proteins by electrophilic products of lipid peroxidation has been associated with governing redox-associated signaling mechanisms, but also as contributing to protein dysfunction leading to organelle and liver injury. In particular the prototypical α,β-unsaturated aldehyde, 4-hydroxy-2-nonenal (HNE), has been extensively studied as marker of increased oxidative stress in hepatocytes. In this study, we combined a LC-MS label-free quantification method and affinity enrichment to assess the dose-dependent insult by HNE on the proteome of rat liver mitochondria. We used a carbonyl-selective probe, the ARP probe, to label HNE-protein adducts and to perform affinity capture at the protein level. Using LC-MS to obtain protein abundance estimates, a list of protein targets was obtained with increasing concentration of HNE used in the exposure studies. In parallel, we performed affinity capture at the peptide level to acquire site-specific information. Examining the concentration-dependence of the protein modifications, we observed distinct reactivity profiles for HNE-protein adduction. Pathway analysis indicated that proteins associated with metabolic processes, including amino acid, fatty acid and glyoxylate and dicarboxylate metabolism, bile acid synthesis and TCA cycle, showed enhanced reactivity to HNE

  20. Therapeutic drug monitoring of tamoxifen using LC-MS/MS.

    PubMed

    Tchu, Simone M; Lynch, Kara L; Wu, Alan H B

    2012-01-01

    Tamoxifen is a selective estrogen receptor modulator (SERM) that is used widely in the treatment of estrogen receptor positive breast cancer (ER+). Therapeutic monitoring of tamoxifen, and its metabolites N-desmethyltamoxifen (NDTam) and 4-hydroxy-N-desmethyltamoxifen (endoxifen), may be clinically useful for guiding treatment decisions. Two significant barriers to tamoxifen efficacy are: (1) variability in conversion of tamoxifen into the potent antiestrogenic metabolite, endoxifen, and (2) poor compliance and adherence to tamoxifen therapy. Therapeutic monitoring can be used to address both of these issues. Low levels of endoxifen indicate either poor compliance or poor metabolism of tamoxifen. Low tamoxifen levels would suggest poor compliance while a low ratio of endoxifen to NDTam would be indicative of poor metabolism. Solid phase extraction of patient serum followed by liquid chromatography tandem mass spectrometry (LC-MS/MS) detection enables rapid, accurate, detection of tamoxifen, N-desmethyltamoxifen, and endoxifen.