Sample records for labelled water method

  1. The Doubly Labeled Water Method for Measuring Human Energy Expenditure: Adaptations for Spaceflight

    NASA Technical Reports Server (NTRS)

    Schulz, Leslie O.

    1991-01-01

    It is essential to determine human energy requirements in space, and the doubly labeled water method has been identified as the most appropriate means of indirect calorimetry to meet this need. The method employs naturally occurring, stable isotopes of hydrogen (H-2, deuterium) and oxygen (O-18) which, after dosing, mix with body water. The deuterium is lost from the body as water while the O-18 is eliminated as both water and CO2. The difference between the two isotope elimination rates is therefore a measure of CO2 production and hence energy expenditure. Spaceflight will present a unique challenge to the application of the doubly labeled water method. Specifically, interpretation of doubly labeled water results assumes that the natural abundance or 'background' levels of the isotopes remain constant during the measurement interval. To address this issue, an equilibration model will be developed in an ongoing ground-based study. As energy requirements of women matched to counterparts in the Astronauts Corps are being determined by doubly labeled water, the baseline isotope concentration will be changed by consumption of 'simulated Shuttle water' which is artificially enriched. One group of subjects will be equilibrated on simulated Shuttle water prior to energy determinations by doubly labeled water while the others will consume simulated Shuttle water after dosing. This process will allow us to derive a prediction equation to mathematically model the effect of changing background isotope concentrations.

  2. Validation of doubly labeled water method using a ruminant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fancy, S.G.; Blanchard, J.M.; Holleman, D.F.

    1986-07-01

    CO/sub 2/ production (CDP, ml CO/sub 2/ . g-1 . h-1) by captive caribou and reindeer (Rangifer tarandus) was measured using the doubly labeled water method (/sup 3/H/sub 2/O and H2(18)O) and compared with CO/sub 2/ expiration rates (VCO/sub 2/), adjusted for CO/sub 2/ losses in CH4 and urine, as determined by open-circuit respirometry. CDP calculated from samples of blood or urine from a reindeer in winter was 1-3% higher than the adjusted VCO/sub 2/. Differences between values derived by the two methods of 5-20% were found in summer trials with caribou. None of these differences were statistically significant (Pmore » greater than 0.05). Differences in summer could in part be explained by the net deposition of /sup 3/H, 18O, and unlabeled CO/sub 2/ in antlers and other growing tissues. Total body water volumes calculated from /sup 3/H/sub 2/O dilution were up to 15% higher than those calculated from H/sub 2/(18)O dilution. The doubly labeled water method appears to be a reasonably accurate method for measuring CDP by caribou and reindeer in winter when growth rates are low, but the method may overestimate CDP by rapidly growing and/or fattening animals.« less

  3. Doubly labeled water method: in vivo oxygen and hydrogen isotope fractionation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schoeller, D.A.; Leitch, C.A.; Brown, C.

    The accuracy and precision of the doubly labeled water method for measuring energy expenditure are influenced by isotope fractionation during evaporative water loss and CO/sub 2/ excretion. To characterize in vivo isotope fractionation, we collected and isotopically analyzed physiological fluids and gases. Breath and transcutaneous water vapor were isotopically fractionated. The degree of fractionation indicated that the former was fractionated under equilibrium control at 37/sup 0/C, and the latter was kinetically fractionated. Sweat and urine were unfractionated. By use of isotopic balance models, the fraction of water lost via fractionating routes was estimated from the isotopic abundances of body water,more » local drinking water, and dietary solids. Fractionated water loss averaged 23% (SD = 10%) of water turnover, which agreed with our previous estimates based on metabolic rate, but there was a systematic difference between the results based on O/sub 2/ and hydrogen. Corrections for isotopic fractionation of water lost in breath and (nonsweat) transcutaneous loss should be made when using labeled water to measure water turnover or CO/sub 2/ production.« less

  4. Energy expenditure in space flight (doubly labelled water method) (8-IML-1)

    NASA Technical Reports Server (NTRS)

    Parsons, Howard G.

    1992-01-01

    The objective of the Energy Expenditure in Space Flight (ESS) experiment is to demonstrate and evaluate the doubly labeled water method of measuring the energy expended by crew members during approximately 7 days in microgravity. The doubly labeled water technique determines carbon dioxide production which is then used to calculate energy expenditure. The method relies on the equilibrium between oxygen in respiratory carbon dioxide and oxygen in body water. Because of this equilibrium, the kinetic of water turnover and respiration are interdependent. Under normal conditions, man contains small but significant amounts of deuterium and oxygen 18. Deuterium is eliminated from the body as water while oxygen 18 is eliminated as water and carbon dioxide. The difference in the turnover rates in the two isotopes is proportional to the carbon dioxide production. Deliberately enriching the total body water with both of these isotopes allows the isotope turnovers to be accurately measured in urine, plasma, or saliva samples. The samples are taken to the laboratory for analysis using an ion-ratio spectrometer.

  5. Validity of the remote food photography method against doubly labeled water among minority preschoolers

    USDA-ARS?s Scientific Manuscript database

    The aim of this study was to determine the validity of energy intake (EI) estimations made using the remote food photography method (RFPM) compared to the doubly labeled water (DLW) method in minority preschool children in a free-living environment. Seven days of food intake and spot urine samples...

  6. A Novel Method for Relative Quantitation of N-Glycans by Isotopic Labeling Using 18O-Water

    PubMed Central

    Tao, Shujuan; Orlando, Ron

    2014-01-01

    Quantitation is an essential aspect of comprehensive glycomics study. Here, a novel isotopic-labeling method is described for N-glycan quantitation using 18O-water. The incorporation of the 18O-labeling into the reducing end of N-glycans is simply and efficiently achieved during peptide-N4-(N-acetyl-β-glucosaminyl) asparagine amidase F release. This process provides a 2-Da mass difference compared with the N-glycans released in 16O-water. A mathematical calculation method was also developed to determine the 18O/16O ratios from isotopic peaks. Application of this method to several standard glycoprotein mixtures and human serum demonstrated that this method can facilitate the relative quantitation of N-glycans over a linear dynamic range of two orders, with high accuracy and reproducibility. PMID:25365792

  7. WaterSense Labeled New Homes

    EPA Pesticide Factsheets

    Homes built to meet EPA's specification can earn the WaterSense label. EPA criteria include WaterSense labeled plumbing fixtures, efficient hot water delivery systems, water-smart landscape design, and other features.

  8. Doubly labelled water assessment of energy expenditure: principle, practice, and promise.

    PubMed

    Westerterp, Klaas R

    2017-07-01

    The doubly labelled water method for the assessment of energy expenditure was first published in 1955, application in humans started in 1982, and it has become the gold standard for human energy requirement under daily living conditions. The method involves enriching the body water of a subject with heavy hydrogen ( 2 H) and heavy oxygen ( 18 O), and then determining the difference in washout kinetics between both isotopes, being a function of carbon dioxide production. In practice, subjects get a measured amount of doubly labelled water ( 2 H 2 18 O) to increase background enrichment of body water for 18 O of 2000 ppm with at least 180 ppm and background enrichment of body water for 2 H of 150 ppm with 120 ppm. Subsequently, the difference between the apparent turnover rates of the hydrogen and oxygen of body water is assessed from blood-, saliva-, or urine samples, collected at the start and end of the observation interval of 1-3 weeks. Samples are analyzed for 18 O and 2 H with isotope ratio mass spectrometry. The doubly labelled water method is the indicated method to measure energy expenditure in any environment, especially with regard to activity energy expenditure, without interference with the behavior of the subjects. Applications include the assessment of energy requirement from total energy expenditure, validation of dietary assessment methods and validation of physical activity assessment methods with doubly labelled water measured energy expenditure as reference, and studies on body mass regulation with energy expenditure as a determinant of energy balance.

  9. Natural abundance deuterium and 18-oxygen effects on the precision of the doubly labeled water method

    NASA Technical Reports Server (NTRS)

    Horvitz, M. A.; Schoeller, D. A.

    2001-01-01

    The doubly labeled water method for measuring total energy expenditure is subject to error from natural variations in the background 2H and 18O in body water. There is disagreement as to whether the variations in background abundances of the two stable isotopes covary and what relative doses of 2H and 18O minimize the impact of variation on the precision of the method. We have performed two studies to investigate the amount and covariance of the background variations. These were a study of urine collected weekly from eight subjects who remained in the Madison, WI locale for 6 wk and frequent urine samples from 14 subjects during round-trip travel to a locale > or = 500 miles from Madison, WI. Background variation in excess of analytical error was detected in six of the eight nontravelers, and covariance was demonstrated in four subjects. Background variation was detected in all 14 travelers, and covariance was demonstrated in 11 subjects. The median slopes of the regression lines of delta2H vs. delta18O were 6 and 7, respectively. Modeling indicated that 2H and 18O doses yielding a 6:1 ratio of final enrichments should minimize this error introduced to the doubly labeled water method.

  10. Natural abundance deuterium and 18-oxygen effects on the precision of the doubly labeled water method.

    PubMed

    Horvitz, M A; Schoeller, D A

    2001-06-01

    The doubly labeled water method for measuring total energy expenditure is subject to error from natural variations in the background 2H and 18O in body water. There is disagreement as to whether the variations in background abundances of the two stable isotopes covary and what relative doses of 2H and 18O minimize the impact of variation on the precision of the method. We have performed two studies to investigate the amount and covariance of the background variations. These were a study of urine collected weekly from eight subjects who remained in the Madison, WI locale for 6 wk and frequent urine samples from 14 subjects during round-trip travel to a locale > or = 500 miles from Madison, WI. Background variation in excess of analytical error was detected in six of the eight nontravelers, and covariance was demonstrated in four subjects. Background variation was detected in all 14 travelers, and covariance was demonstrated in 11 subjects. The median slopes of the regression lines of delta2H vs. delta18O were 6 and 7, respectively. Modeling indicated that 2H and 18O doses yielding a 6:1 ratio of final enrichments should minimize this error introduced to the doubly labeled water method.

  11. Comparison of doubly labeled water with respirometry at low- and high-activity levels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Westerterp, K.R.; Brouns, F.; Saris, W.H.

    1988-07-01

    In previous studies the doubly labeled water method for measuring energy expenditure in free-living humans has been validated against respirometry under sedentary conditions. In the present investigation, energy expenditure is measured simultaneously with doubly labeled water and respirometry at low- and high-activity levels. Over 6 days, five subjects were measured doing mainly sedentary activities like desk work; their average daily metabolic rate was 1.40 +/- 0.09 (SD) times sleeping metabolic rate. Four subjects were measured twice over 3.5 days, including 2 days with heavy bicycle ergometer work, resulting in an average daily metabolic rate of 2.61 +/- 0.25 (SD) timesmore » sleeping metabolic rate. At the low-activity level, energy expenditures from the doubly labeled water method were on the average 1.4 +/- 3.9% (SD) larger than those from respirometry. At the high-activity level, the doubly labeled water method yielded values that were 1.0 +/- 7.0% (SD) lower than those from respirometry. Results demonstrate the utility of the doubly labeled water method for the determination of energy expenditure in the range of activity levels in daily life.« less

  12. Energy Requirement Assessment and Water Turnover in Japanese College Wrestlers Using the Doubly Labeled Water Method.

    PubMed

    Sagayama, Hiroyuki; Kondo, Emi; Shiose, Keisuke; Yamada, Yosuke; Motonaga, Keiko; Ouchi, Shiori; Kamei, Akiko; Osawa, Takuya; Nakajima, Kohei; Takahashi, Hideyuki; Higaki, Yasuki; Tanaka, Hiroaki

    2017-01-01

    Estimated energy requirements (EERs) are important for sports based on body weight classifications to aid in weight management. The basis for establishing EERs varies and includes self-reported energy intake (EI), predicted energy expenditure, and measured daily energy expenditure. Currently, however, no studies have been performed with male wrestlers using the highly accurate and precise doubly labeled water (DLW) method to estimate energy and fluid requirement. The primary aim of this study was to compare total energy expenditure (TEE), self-reported EI, and the difference in collegiate wrestlers during a normal training period using the DLW method. The secondary aims were to measure the water turnover and the physical activity level (PAL) of the athletes, and to examine the accuracy of two currently used equations to predict EER. Ten healthy males (age, 20.4±0.5 y) belonging to the East-Japan college league participated in this study. TEE was measured using the DLW method, and EI was assessed with self-reported dietary records for ~1 wk. There was a significant difference between TEE (17.9±2.5 MJ•d -1 [4,283±590 kcal•d -1 ]) and self-reported EI (14.4±3.3 MJ•d -1 [3,446±799 kcal•d -1 ]), a difference of 19%. The water turnover was 4.61±0.73 L•d -1 . The measured PAL (2.6±0.3) was higher than two predicted values during the training season and thus the two EER prediction equations produced underestimated values relative to DLW. We found that previous EERs were underestimating requirements in collegiate wrestlers and that those estimates should be revised.

  13. Use of doubly labeled water technique in soldiers training for jungle warfare

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Forbes-Ewan, C.H.; Morrissey, B.L.; Gregg, G.C.

    1989-07-01

    The doubly labeled water method was used to estimate the energy expended by four members of an Australian Army platoon (34 soldiers) engaged in training for jungle warfare. Each subject received an oral isotope dose sufficient to raise isotope levels by 200-250 ({sup 18}O) and 100-120 ppm ({sup 2}H). The experimental period was 7 days. Concurrently, a factorial estimate of the energy expenditure of the platoon was conducted. Also, a food intake-energy balance study was conducted for the platoon. Mean daily energy expenditure by the doubly labeled water method was 4,750 kcal (range 4,152-5,394 kcal). The factorial estimate of meanmore » daily energy expenditure was 4,535 kcal. Because of inherent inaccuracies in the food intake-energy balance technique, we were able to conclude only that energy expenditure, as measured by this method, was greater than the estimated mean daily intake of 4,040 kcal. The doubly labeled water technique was well tolerated, is noninvasive, and appears to be suitable in a wide range of field applications.« less

  14. Effect of bolus fluid intake on energy expenditure values as determined by the doubly labeled water method

    NASA Technical Reports Server (NTRS)

    Drews, D.; Stein, T. P.

    1992-01-01

    The doubly labeled water (DLW, 2H(2)18O) method is a highly accurate method for measuring energy expenditure (EE). A possible source of error is bolus fluid intake before body water sampling. If there is bolus fluid intake immediately before body water sampling, the saliva may reflect the ingested water disproportionately, because the ingested water may not have had time to mix fully with the body water pool. To ascertain the magnitude of this problem, EE was measured over a 5-day period by the DLW method. Six subjects were dosed with 2H2(18)O. After the reference salivas for the two-point determination were obtained, subjects drank water (700-1,000 ml), and serial saliva samples were collected for the next 3 h. Expressing the postbolus saliva enrichments as a percentage of the prebolus value, we found 1) a minimum in the saliva isotopic enrichments were reached at approximately 30 min with the minimum for 2H (95.48 +/- 0.43%) being significantly lower than the minimum for 18O (97.55 +/- 0.44, P less than 0.05) and 2) EE values calculated using the postbolus isotopic enrichments are appreciably higher (19.9 +/- 7.5%) than the prebolus reference values. In conclusion, it is not advisable to collect saliva samples for DLW measurements within approximately 1 h of bolus fluid intake.

  15. PRN 93-3: Labeling Statement Prohibiting Application to Water

    EPA Pesticide Factsheets

    This notice explaining the policy on label statement prohibiting pesticide application to water pertains only to the labeling statement on pesticide products. It does not address the term wetlands as defined with respect to the Clean Water Act.

  16. Tritium labeling of antisense oligonucleotides by exchange with tritiated water.

    PubMed Central

    Graham, M J; Freier, S M; Crooke, R M; Ecker, D J; Maslova, R N; Lesnik, E A

    1993-01-01

    We describe a simple, efficient, procedure for labeling oligonucleotides to high specific activity (< 1 x 10(8) cpm/mumol) by hydrogen exchange with tritiated water at the C8 positions of purines in the presence of beta-mercaptoethanol, an effective radical scavenger. Approximately 90% of the starting material is recovered as intact, labeled oligonucleotide. The radiolabeled compounds are stable in biological systems; greater than 90% of the specific activity is retained after 72 hr incubation at 37 degrees C in serum-containing media. Data obtained from in vitro cellular uptake experiments using oligonucleotides labeled by this method are similar to those obtained using 35S or 14C-labeled compounds. Because this protocol is solely dependent upon the existence of purine residues, it should be useful for radiolabeling modified as well as unmodified phosphodiester oligonucleotides. Images PMID:8367289

  17. WaterSense Labeled Homes Quick Reference Guide

    EPA Pesticide Factsheets

    Green building has grown from a niche market to a savvy business strategy. WaterSense labeled homes capitalize on consumer demand by offering homeowners a whole-house solution to help them save water, energy, and money.

  18. Validity of the Remote Food Photography Method against Doubly Labeled Water among Minority Preschoolers

    PubMed Central

    Nicklas, Theresa; Saab, Rabab; Islam, Noemi G.; Wong, William; Butte, Nancy; Schulin, Rebecca; Liu, Yan; Apolzan, John W.; Myers, Candice A.; Martin, Corby K.

    2017-01-01

    Objective To determine the validity of energy intake (EI) estimations made using the Remote Food Photography Method (RFPM) compared to the doubly-labeled water (DLW) method in minority preschool children in a free-living environment. Methods Seven days of food intake and spot urine samples excluding first void collections for DLW analysis were obtained on 39 3-to-5 year old Hispanic and African American children. Using an iPhone, caregivers captured before and after pictures of the child’s intake and pictures were wirelessly transmitted to trained raters who estimated portion size using existing visual estimation procedures and energy and macronutrients were calculated. Paired t-test, mean differences and Bland-Altman limits of agreement were performed. Results The mean EI using the RFPM was 1,191 ± 256 kcal/d and 1,412 ± 220 kcal/d by the DLW method, resulting in a mean underestimate of 222 kcal/d (−15.6%) (p<0.0001) that was consistent regardless of intake. The RFPM underestimated EI by −28.5% in 34 children and overestimated EI by 15.6% in 5 children. Conclusions The RFPM underestimated total EI when compared to the DLW method among preschoolers. Further refinement of the RFPM is needed for assessing EI of young children. PMID:28758370

  19. Inter-labeler and intra-labeler variability of condition severity classification models using active and passive learning methods.

    PubMed

    Nissim, Nir; Shahar, Yuval; Elovici, Yuval; Hripcsak, George; Moskovitch, Robert

    2017-09-01

    Labeling instances by domain experts for classification is often time consuming and expensive. To reduce such labeling efforts, we had proposed the application of active learning (AL) methods, introduced our CAESAR-ALE framework for classifying the severity of clinical conditions, and shown its significant reduction of labeling efforts. The use of any of three AL methods (one well known [SVM-Margin], and two that we introduced [Exploitation and Combination_XA]) significantly reduced (by 48% to 64%) condition labeling efforts, compared to standard passive (random instance-selection) SVM learning. Furthermore, our new AL methods achieved maximal accuracy using 12% fewer labeled cases than the SVM-Margin AL method. However, because labelers have varying levels of expertise, a major issue associated with learning methods, and AL methods in particular, is how to best to use the labeling provided by a committee of labelers. First, we wanted to know, based on the labelers' learning curves, whether using AL methods (versus standard passive learning methods) has an effect on the Intra-labeler variability (within the learning curve of each labeler) and inter-labeler variability (among the learning curves of different labelers). Then, we wanted to examine the effect of learning (either passively or actively) from the labels created by the majority consensus of a group of labelers. We used our CAESAR-ALE framework for classifying the severity of clinical conditions, the three AL methods and the passive learning method, as mentioned above, to induce the classifications models. We used a dataset of 516 clinical conditions and their severity labeling, represented by features aggregated from the medical records of 1.9 million patients treated at Columbia University Medical Center. We analyzed the variance of the classification performance within (intra-labeler), and especially among (inter-labeler) the classification models that were induced by using the labels provided by seven

  20. Determination of energy expenditure during heavy exercise, normal daily activity, and sleep using the doubly-labelled-water (/sup 2/H/sub 2/ 18O) method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stein, T.P.; Hoyt, R.W.; Settle, R.G.

    1987-03-01

    Energy expenditure of four subjects was measured by the doubly-labelled-water (/sup 2/H/sub 2/ 18O) method to determine if energy expenditure could be determined over short periods. Three subjects were studied while they performed 8 h of heavy exercise in a laboratory environment. Urine and blood samples were taken before and after exercise. Estimated energy expended during 8 h of high-intensity exercise for three subjects was 757 +/- 118 kcal/h by the doubly-labelled-water method using urine and a two-point calculation, which compared favorably with 735 +/- 82 kcal/h obtained by respiratory gas exchange. For the fourth subject, daytime, nighttime, and dailymore » energy expenditure was calculated by both the two-pair method and decay-curve analysis of urine and saliva samples collected in the morning and at night. Daytime and nighttime energy expenditures differed significantly (p less than 0.05).« less

  1. Inter-Labeler and Intra-Labeler Variability of Condition Severity Classification Models Using Active and Passive Learning Methods

    PubMed Central

    Nissim, Nir; Shahar, Yuval; Boland, Mary Regina; Tatonetti, Nicholas P; Elovici, Yuval; Hripcsak, George; Moskovitch, Robert

    2018-01-01

    Background and Objectives Labeling instances by domain experts for classification is often time consuming and expensive. To reduce such labeling efforts, we had proposed the application of active learning (AL) methods, introduced our CAESAR-ALE framework for classifying the severity of clinical conditions, and shown its significant reduction of labeling efforts. The use of any of three AL methods (one well known [SVM-Margin], and two that we introduced [Exploitation and Combination_XA]) significantly reduced (by 48% to 64%) condition labeling efforts, compared to standard passive (random instance-selection) SVM learning. Furthermore, our new AL methods achieved maximal accuracy using 12% fewer labeled cases than the SVM-Margin AL method. However, because labelers have varying levels of expertise, a major issue associated with learning methods, and AL methods in particular, is how to best to use the labeling provided by a committee of labelers. First, we wanted to know, based on the labelers’ learning curves, whether using AL methods (versus standard passive learning methods) has an effect on the Intra-labeler variability (within the learning curve of each labeler) and inter-labeler variability (among the learning curves of different labelers). Then, we wanted to examine the effect of learning (either passively or actively) from the labels created by the majority consensus of a group of labelers. Methods We used our CAESAR-ALE framework for classifying the severity of clinical conditions, the three AL methods and the passive learning method, as mentioned above, to induce the classifications models. We used a dataset of 516 clinical conditions and their severity labeling, represented by features aggregated from the medical records of 1.9 million patients treated at Columbia University Medical Center. We analyzed the variance of the classification performance within (intra-labeler), and especially among (inter-labeler) the classification models that were induced by

  2. Validity of the Remote Food Photography Method Against Doubly Labeled Water Among Minority Preschoolers.

    PubMed

    Nicklas, Theresa; Saab, Rabab; Islam, Noemi G; Wong, William; Butte, Nancy; Schulin, Rebecca; Liu, Yan; Apolzan, John W; Myers, Candice A; Martin, Corby K

    2017-09-01

    The aim of this study was to determine the validity of energy intake (EI) estimations made using the remote food photography method (RFPM) compared to the doubly labeled water (DLW) method in minority preschool children in a free-living environment. Seven days of food intake and spot urine samples excluding first void collections for DLW analysis were obtained on thirty-nine 3- to 5-year-old Hispanic and African American children. Using an iPhone, caregivers captured before and after pictures of each child's intake, pictures were wirelessly transmitted to trained raters who estimated portion size using existing visual estimation procedures, and energy and macronutrients were calculated. Paired t tests, mean differences, and Bland-Altman limits of agreement were performed. The mean EI was 1,191 ± 256 kcal/d using the RFPM and 1,412 ± 220 kcal/d using the DLW method, resulting in a mean underestimate of 222 kcal/d (-15.6%; P < 0.0001) that was consistent regardless of intake. The RFPM underestimated EI by -28.5% in 34 children and overestimated EI by 15.6% in 5 children. The RFPM underestimated total EI when compared to the DLW method among preschoolers. Further refinement of the RFPM is needed for assessing the EI of young children. © 2017 The Obesity Society.

  3. 16 CFR 300.11 - Improper methods of labeling.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Improper methods of labeling. 300.11 Section 300.11 Commercial Practices FEDERAL TRADE COMMISSION REGULATIONS UNDER SPECIFIC ACTS OF CONGRESS RULES AND REGULATIONS UNDER THE WOOL PRODUCTS LABELING ACT OF 1939 Labeling § 300.11 Improper methods of...

  4. Evaluation of three methods of platelet labelling.

    PubMed

    Mortelmans, L; Verbruggen, A; De Roo, M; Vermylen, J

    1986-07-01

    The study of the kinetics of labelled platelets makes sense only when the platelets preserve their viability after separation and labelling. The separation and labelling procedures described in the manual of two producers of 111In-oxinate (Amersham, Mallinckrodt) have been evaluated by in vitro aggregation tests. The method of Mallinckrodt diminished the aggregation capacities of the thrombocytes. The labelled platelets with normal in vitro aggregation response (Amersham) were tested in vivo in 11 patients who underwent peripheral bypass surgery. The platelet half-life and the platelet accumulation on bypass grafts were checked one week post-operatively. Because of the poor in vivo response of both methods (exponential half-life curve and bad graft visualization), a third method was optimized in our laboratory with good in vitro and in vivo results in 12 patients.

  5. Use of an automated chromium reduction system for hydrogen isotope ratio analysis of physiological fluids applied to doubly labeled water analysis.

    PubMed

    Schoeller, D A; Colligan, A S; Shriver, T; Avak, H; Bartok-Olson, C

    2000-09-01

    The doubly labeled water method is commonly used to measure total energy expenditure in free-living subjects. The method, however, requires accurate and precise deuterium abundance determinations, which can be laborious. The aim of this study was to evaluate a fully automated, high-throughput, chromium reduction technique for the measurement of deuterium abundances in physiological fluids. The chromium technique was compared with an off-line zinc bomb reduction technique and also subjected to test-retest analysis. Analysis of international water standards demonstrated that the chromium technique was accurate and had a within-day precision of <1 per thousand. Addition of organic matter to water samples demonstrated that the technique was sensitive to interference at levels between 2 and 5 g l(-1). Physiological samples could be analyzed without this interference, plasma by 10000 Da exclusion filtration, saliva by sedimentation and urine by decolorizing with carbon black. Chromium reduction of urine specimens from doubly labeled water studies indicated no bias relative to zinc reduction with a mean difference in calculated energy expenditure of -0.2 +/- 3.9%. Blinded reanalysis of urine specimens from a second doubly labeled water study demonstrated a test-retest coefficient of variation of 4%. The chromium reduction method was found to be a rapid, accurate and precise method for the analysis of urine specimens from doubly labeled water. Copyright 2000 John Wiley & Sons, Ltd.

  6. [Progress in stable isotope labeled quantitative proteomics methods].

    PubMed

    Zhou, Yuan; Shan, Yichu; Zhang, Lihua; Zhang, Yukui

    2013-06-01

    Quantitative proteomics is an important research field in post-genomics era. There are two strategies for proteome quantification: label-free methods and stable isotope labeling methods which have become the most important strategy for quantitative proteomics at present. In the past few years, a number of quantitative methods have been developed, which support the fast development in biology research. In this work, we discuss the progress in the stable isotope labeling methods for quantitative proteomics including relative and absolute quantitative proteomics, and then give our opinions on the outlook of proteome quantification methods.

  7. Seasonal changes in background levels of deuterium and oxygen-18 prove water drinking by harp seals, which affects the use of the doubly labelled water method.

    PubMed

    Nordøy, Erling S; Lager, Anne R; Schots, Pauke C

    2017-12-01

    The aim of this study was to monitor seasonal changes in stable isotopes of pool freshwater and harp seal ( Phoca groenlandica ) body water, and to study whether these potential seasonal changes might bias results obtained using the doubly labelled water (DLW) method when measuring energy expenditure in animals with access to freshwater. Seasonal changes in the background levels of deuterium and oxygen-18 in the body water of four captive harp seals and in the freshwater pool in which they were kept were measured over a time period of 1 year. The seals were offered daily amounts of capelin and kept under a seasonal photoperiod of 69°N. Large seasonal variations of deuterium and oxygen-18 in the pool water were measured, and the isotope abundance in the body water showed similar seasonal changes to the pool water. This shows that the seals were continuously equilibrating with the surrounding water as a result of significant daily water drinking. Variations in background levels of deuterium and oxygen-18 in freshwater sources may be due to seasonal changes in physical processes such as precipitation and evaporation that cause fractionation of isotopes. Rapid and abrupt changes in the background levels of deuterium and oxygen-18 may complicate calculation of energy expenditure by use of the DLW method. It is therefore strongly recommended that analysis of seasonal changes in background levels of isotopes is performed before the DLW method is applied on (free-ranging) animals, and to use a control group in order to correct for changes in background levels. © 2017. Published by The Company of Biologists Ltd.

  8. WaterSense Labeled Weather-Based Irrigation Controller Fact Sheet

    EPA Pesticide Factsheets

    WaterSense labeled irrigation controllers, which act like a thermostat for your sprinkler system by telling it when to turn on and off, use local weather and landscape conditions to tailor watering schedules to actual conditions on the site.

  9. A diagram retrieval method with multi-label learning

    NASA Astrophysics Data System (ADS)

    Fu, Songping; Lu, Xiaoqing; Liu, Lu; Qu, Jingwei; Tang, Zhi

    2015-01-01

    In recent years, the retrieval of plane geometry figures (PGFs) has attracted increasing attention in the fields of mathematics education and computer science. However, the high cost of matching complex PGF features leads to the low efficiency of most retrieval systems. This paper proposes an indirect classification method based on multi-label learning, which improves retrieval efficiency by reducing the scope of compare operation from the whole database to small candidate groups. Label correlations among PGFs are taken into account for the multi-label classification task. The primitive feature selection for multi-label learning and the feature description of visual geometric elements are conducted individually to match similar PGFs. The experiment results show the competitive performance of the proposed method compared with existing PGF retrieval methods in terms of both time consumption and retrieval quality.

  10. Multiple tag labeling method for DNA sequencing

    DOEpatents

    Mathies, R.A.; Huang, X.C.; Quesada, M.A.

    1995-07-25

    A DNA sequencing method is described which uses single lane or channel electrophoresis. Sequencing fragments are separated in the lane and detected using a laser-excited, confocal fluorescence scanner. Each set of DNA sequencing fragments is separated in the same lane and then distinguished using a binary coding scheme employing only two different fluorescent labels. Also described is a method of using radioisotope labels. 5 figs.

  11. Multiple tag labeling method for DNA sequencing

    DOEpatents

    Mathies, Richard A.; Huang, Xiaohua C.; Quesada, Mark A.

    1995-01-01

    A DNA sequencing method described which uses single lane or channel electrophoresis. Sequencing fragments are separated in said lane and detected using a laser-excited, confocal fluorescence scanner. Each set of DNA sequencing fragments is separated in the same lane and then distinguished using a binary coding scheme employing only two different fluorescent labels. Also described is a method of using radio-isotope labels.

  12. Stem Cell Monitoring with a Direct or Indirect Labeling Method.

    PubMed

    Kim, Min Hwan; Lee, Yong Jin; Kang, Joo Hyun

    2016-12-01

    The molecular imaging techniques allow monitoring of the transplanted cells in the same individuals over time, from early localization to the survival, migration, and differentiation. Generally, there are two methods of stem cell labeling: direct and indirect labeling methods. The direct labeling method introduces a labeling agent into the cell, which is stably incorporated or attached to the cells prior to transplantation. Direct labeling of cells with radionuclides is a simple method with relatively fewer adverse events related to genetic responses. However, it can only allow short-term distribution of transplanted cells because of the decreasing imaging signal with radiodecay, according to the physical half-lives, or the signal becomes more diffuse with cell division and dispersion. The indirect labeling method is based on the expression of a reporter gene transduced into the cell before transplantation, which is then visualized upon the injection of an appropriate probe or substrate. In this review, various imaging strategies to monitor the survival and behavior change of transplanted stem cells are covered. Taking these new approaches together, the direct and indirect labeling methods may provide new insights on the roles of in vivo stem cell monitoring, from bench to bedside.

  13. Kinugasa reactions in water: from green chemistry to bioorthogonal labelling.

    PubMed

    Chigrinova, Mariya; MacKenzie, Douglas A; Sherratt, Allison R; Cheung, Lawrence L W; Pezacki, John Paul; Pezacki, Paul

    2015-04-16

    The Kinugasa reaction has become an efficient method for the direct synthesis of β-lactams from substituted nitrones and copper(I) acetylides. In recent years, the reaction scope has been expanded to include the use of water as the solvent, and with micelle-promoted [3+2] cycloadditions followed by rearrangement furnishing high yields of β-lactams. The high yields of stable products under aqueous conditions render the modified Kinugasa reaction amenable to metabolic labelling and bioorthogonal applications. Herein, the development of methods for use of the Kinugasa reaction in aqueous media is reviewed, with emphasis on its potential use as a bioorthogonal coupling strategy.

  14. Methane production in ruminants: Its effect on the doubly labeled water method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Midwood, A.J.; Haggarty, P.; McGaw, B.A.

    1989-12-01

    The doubly labeled water (DLW) technique for measuring CO2 production (rCO2) in free-living animals requires an assessment of the elimination of both 2H and 18O from the body over a long period of time. To calculate rCO2, it is necessary to calculate water turnover (rH2O) from the 2H flux rate. In ruminant animals, the accuracy of this calculation is affected by the loss of 2H in methane. We have quantified the effect of methane production (rCH4) on the 2H flux rate, determined in four sheep given 2H2O. The methane produced was depleted in 2H relative to the urine. A relationshipmore » between the enrichment of the methane and urine was established. The ratio of urine to methane enrichment was found on average to be 0.6536, and this value was unaffected by the level of rCH4 but showed some dependence on the absolute concentration of 2H in urine. For this reason, the ratio value obtained from four sheep not given 2H2O was different, a mean of 0.6886 was measured, this ratio was unaffected by changes in the diet supplied to the animals. Computer modeling was used to illustrate the dependence of the isotopically derived value for rCO2 on not only rCH4 but also the magnitude of rCO2 itself. The effect of rCH4 on the DLW method can be predicted from the observed ratio of rCO2 to rCH4 and the value of 0.6536 obtained for the ratio of methane to urine enrichment. With the use of data from several studies at this Institute, a limited range of 10 to 20 was found for rCO2/rCH4 in animals fed at or above maintenance.« less

  15. Novel image processing method study for a label-free optical biosensor

    NASA Astrophysics Data System (ADS)

    Yang, Chenhao; Wei, Li'an; Yang, Rusong; Feng, Ying

    2015-10-01

    Optical biosensor is generally divided into labeled type and label-free type, the former mainly contains fluorescence labeled method and radioactive-labeled method, while fluorescence-labeled method is more mature in the application. The mainly image processing methods of fluorescent-labeled biosensor includes smooth filtering, artificial gridding and constant thresholding. Since some fluorescent molecules may influence the biological reaction, label-free methods have been the main developing direction of optical biosensors nowadays. The using of wider field of view and larger angle of incidence light path which could effectively improve the sensitivity of the label-free biosensor also brought more difficulties in image processing, comparing with the fluorescent-labeled biosensor. Otsu's method is widely applied in machine vision, etc, which choose the threshold to minimize the intraclass variance of the thresholded black and white pixels. It's capacity-constrained with the asymmetrical distribution of images as a global threshold segmentation. In order to solve the irregularity of light intensity on the transducer, we improved the algorithm. In this paper, we present a new image processing algorithm based on a reflectance modulation biosensor platform, which mainly comprises the design of sliding normalization algorithm for image rectification and utilizing the improved otsu's method for image segmentation, in order to implement automatic recognition of target areas. Finally we used adaptive gridding method extracting the target parameters for analysis. Those methods could improve the efficiency of image processing, reduce human intervention, enhance the reliability of experiments and laid the foundation for the realization of high throughput of label-free optical biosensors.

  16. Validation of the doubly labeled water method using off-axis integrated cavity output spectroscopy and isotope ratio mass spectrometry.

    PubMed

    Melanson, Edward L; Swibas, Tracy; Kohrt, Wendy M; Catenacci, Vicki A; Creasy, Seth A; Plasqui, Guy; Wouters, Loek; Speakman, John R; Berman, Elena S F

    2018-02-01

    When the doubly labeled water (DLW) method is used to measure total daily energy expenditure (TDEE), isotope measurements are typically performed using isotope ratio mass spectrometry (IRMS). New technologies, such as off-axis integrated cavity output spectroscopy (OA-ICOS) provide comparable isotopic measurements of standard waters and human urine samples, but the accuracy of carbon dioxide production (V̇co 2 ) determined with OA-ICOS has not been demonstrated. We compared simultaneous measurement V̇co 2 obtained using whole-room indirect calorimetry (IC) with DLW-based measurements from IRMS and OA-ICOS. Seventeen subjects (10 female; 22 to 63 yr) were studied for 7 consecutive days in the IC. Subjects consumed a dose of 0.25 g H 2 18 O (98% APE) and 0.14 g 2 H 2 O (99.8% APE) per kilogram of total body water, and urine samples were obtained on days 1 and 8 to measure average daily V̇co 2 using OA-ICOS and IRMS. V̇co 2 was calculated using both the plateau and intercept methods. There were no differences in V̇co 2 measured by OA-ICOS or IRMS compared with IC when the plateau method was used. When the intercept method was used, V̇co 2 using OA-ICOS did not differ from IC, but V̇co 2 measured using IRMS was significantly lower than IC. Accuracy (~1-5%), precision (~8%), intraclass correlation coefficients ( R = 0.87-90), and root mean squared error (30-40 liters/day) of V̇co 2 measured by OA-ICOS and IRMS were similar. Both OA-ICOS and IRMS produced measurements of V̇co 2 with comparable accuracy and precision compared with IC.

  17. Document clustering methods, document cluster label disambiguation methods, document clustering apparatuses, and articles of manufacture

    DOEpatents

    Sanfilippo, Antonio [Richland, WA; Calapristi, Augustin J [West Richland, WA; Crow, Vernon L [Richland, WA; Hetzler, Elizabeth G [Kennewick, WA; Turner, Alan E [Kennewick, WA

    2009-12-22

    Document clustering methods, document cluster label disambiguation methods, document clustering apparatuses, and articles of manufacture are described. In one aspect, a document clustering method includes providing a document set comprising a plurality of documents, providing a cluster comprising a subset of the documents of the document set, using a plurality of terms of the documents, providing a cluster label indicative of subject matter content of the documents of the cluster, wherein the cluster label comprises a plurality of word senses, and selecting one of the word senses of the cluster label.

  18. Energy Requirement Assessment in Japanese Table Tennis Players Using the Doubly Labeled Water Method.

    PubMed

    Sagayama, Hiroyuki; Hamaguchi, Genki; Toguchi, Makiko; Ichikawa, Mamiko; Yamada, Yosuke; Ebine, Naoyuki; Higaki, Yasuki; Tanaka, Hiroaki

    2017-10-01

    Total daily energy expenditure (TEE) and physical activity level (PAL) are important for adequate nutritional management in athletes. The PAL of table tennis has been estimated to about 2.0: it is categorized as a moderateactivity sport (4.0 metabolic equivalents [METs]) in the Compendium of Physical Activities. However, modern table tennis makes high physiological demands. The aims of the current study were to examine (1) TEE and PAL of competitive table tennis players and (2) the physiological demands of various types of table tennis practice. In Experiment 1, we measured TEE and PAL in 10 Japanese college competitive table tennis players (aged 19.9 ± 1.1 years) using the doubly labeled water (DLW) method during training and with an exercise training log and self-reported energy intake. TEE was 15.5 ± 1.9 MJ·day -1 (3695 ± 449 kcal·day -1 ); PAL was 2.53 ± 0.25; and the average training duration was 181 ± 38 min·day -1 . In Experiment 2, we measured METs of five different practices in seven college competition players (20.6 ± 1.2 years). Three practices without footwork were 4.5-5.2 METs, and two practices with footwork were 9.5-11.5 METs. Table tennis practices averaged 7.1 ± 3.2 METS demonstrating similarities with other vigorous racket sports. In conclusion the current Compendium of Physical Activities underestimates the physiological demands of table tennis practice for competition; the estimated energy requirement should be based on DLW method data.

  19. 16 CFR 300.5 - Required label and method of affixing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Required label and method of affixing. 300.5 Section 300.5 Commercial Practices FEDERAL TRADE COMMISSION REGULATIONS UNDER SPECIFIC ACTS OF CONGRESS RULES AND REGULATIONS UNDER THE WOOL PRODUCTS LABELING ACT OF 1939 Labeling § 300.5 Required label and...

  20. Reductive methods for isotopic labeling of antibiotics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Champney, W.S.

    1989-08-15

    Methods for the reductive methylation of the amino groups of eight different antibiotics using {sup 3}HCOH or H{sup 14}COH are presented. The reductive labeling of an additional seven antibiotics by NaB{sub 3}H{sub 4} is also described. The specific activity of the methyl-labeled drugs was determined by a phosphocellulose paper binding assay. Two quantitative assays for these compounds based on the reactivity of the antibiotic amino groups with fluorescamine and of the aldehyde and ketone groups with 2,4-dinitrophenylhydrazine are also presented. Data on the cellular uptake and ribosome binding of these labeled compounds are also presented.

  1. Alcohol Warning Label Awareness and Attention: A Multi-method Study.

    PubMed

    Pham, Cuong; Rundle-Thiele, Sharyn; Parkinson, Joy; Li, Shanshi

    2018-01-01

    Evaluation of alcohol warning labels requires careful consideration ensuring that research captures more than awareness given that labels may not be prominent enough to attract attention. This study investigates attention of current in market alcohol warning labels and examines whether attention can be enhanced through theoretically informed design. Attention scores obtained through self-report methods are compared to objective measures (eye-tracking). A multi-method experimental design was used delivering four conditions, namely control, colour, size and colour and size. The first study (n = 559) involved a self-report survey to measure attention. The second study (n = 87) utilized eye-tracking to measure fixation count and duration and time to first fixation. Analysis of Variance (ANOVA) was utilized. Eye-tracking identified that 60% of participants looked at the current in market alcohol warning label while 81% looked at the optimized design (larger and red). In line with observed attention self-reported attention increased for the optimized design. The current study casts doubt on dominant practices (largely self-report), which have been used to evaluate alcohol warning labels. Awareness cannot be used to assess warning label effectiveness in isolation in cases where attention does not occur 100% of the time. Mixed methods permit objective data collection methodologies to be triangulated with surveys to assess warning label effectiveness. Attention should be incorporated as a measure in warning label effectiveness evaluations. Colour and size changes to the existing Australian warning labels aided by theoretically informed design increased attention. © The Author 2017. Medical Council on Alcohol and Oxford University Press. All rights reserved.

  2. Refining cotton-wick method for 15N plant labelling.

    NASA Astrophysics Data System (ADS)

    Fustec, Joëlle; Mahieu, Stéphanie

    2010-05-01

    The symbiosis Fabaceae/Rhizobiaceae plays a critical role in the nitrogen cycle. It gives the plant the ability to fix high amounts of atmospheric N. A part of this N can be transferred to the soil via rhizodeposition. The contribution of Fabaceae to the soil N pool is difficult to measure, since it is necessary for assessing N benefits for other crops, for soil biological activity, and for reducing water pollution in sustainable agriculture (Fustec, 2009). The aim of this study was to test and improve the reliability of the 15N cotton-wick method for measuring the soil N derived from plant rhizodeposition (Mahieu et al., 2007). The effects of the concentration of the 15N-urea labelling solution and of the feeding frequency (continuous or pulses) on the assessment of nitrogen rhizodeposition were studied in two greenhouse experiments using the field pea (Pisum sativum L.) and the non-nodulating isoline P2. The plant parts and the soil were prepared for 15N:14N measurements for assessing N rhizodeposition (Mahieu et al., 2009). The fraction of plants' belowground nitrogen allocated to rhizodeposition in both Frisson pea and P2 was 20 to more than 50% higher when plants were labelled continuously than when they were labelled using fortnightly pulses. Our results suggested that when 15N root enrichment was high, nitrogen rhizodeposition was underestimated only for plants that were 15N-fed by fortnightly pulses, and not in plants 15N-fed continuously. This phenomenon was especially observed for plants relying on symbiotic N fixation for N acquisition; it may be linked to the concentration of the labelling solution. In conclusion, N rhizodeposition assessment was strongly influenced by the 15N-feeding frequency and the concentration of the labelling solution. The estimation of N rhizodeposition was more reliable when plants were labelled continuously with a dilute solution of 15N urea. Fustec et al. 2009. Agron. Sustain. Dev., DOI 10.1051/agro/2009003, in press. Mahieu

  3. An isotope-dilution standard GC/MS/MS method for steroid hormones in water

    USGS Publications Warehouse

    Foreman, William T.; Gray, James L.; ReVello, Rhiannon C.; Lindley, Chris E.; Losche, Scott A.

    2013-01-01

    An isotope-dilution quantification method was developed for 20 natural and synthetic steroid hormones and additional compounds in filtered and unfiltered water. Deuterium- or carbon-13-labeled isotope-dilution standards (IDSs) are added to the water sample, which is passed through an octadecylsilyl solid-phase extraction (SPE) disk. Following extract cleanup using Florisil SPE, method compounds are converted to trimethylsilyl derivatives and analyzed by gas chromatography with tandem mass spectrometry. Validation matrices included reagent water, wastewater-affected surface water, and primary (no biological treatment) and secondary wastewater effluent. Overall method recovery for all analytes in these matrices averaged 100%; with overall relative standard deviation of 28%. Mean recoveries of the 20 individual analytes for spiked reagent-water samples prepared along with field samples analyzed in 2009–2010 ranged from 84–104%, with relative standard deviations of 6–36%. Detection levels estimated using ASTM International’s D6091–07 procedure range from 0.4 to 4 ng/L for 17 analytes. Higher censoring levels of 100 ng/L for bisphenol A and 200 ng/L for cholesterol and 3-beta-coprostanol are used to prevent bias and false positives associated with the presence of these analytes in blanks. Absolute method recoveries of the IDSs provide sample-specific performance information and guide data reporting. Careful selection of labeled compounds for use as IDSs is important because both inexact IDS-analyte matches and deuterium label loss affect an IDS’s ability to emulate analyte performance. Six IDS compounds initially tested and applied in this method exhibited deuterium loss and are not used in the final method.

  4. Apparatus and method for preparing oxygen-15 labeled water H.sub.2 [.sup.15 O] in an injectable form for use in positron emission tomography

    DOEpatents

    Ferrieri, Richard A.; Schlyer, David J.; Alexoff, David

    1996-01-09

    A handling and processing apparatus for preparing Oxygen-15 labeled water (H.sub.2 [.sup.15 O]) in injectable form for use in Positron Emission Tomography from preferably H.sub.2 [.sup.15 O] produced by irradiating a flowing gas target of nitrogen and hydrogen. The apparatus includes a collector for receiving and directing a gas containing H.sub.2 [.sup.15 O] gas and impurities, mainly ammonia (NH.sub.3) gas into sterile water to trap the H.sub.2 [.sup.15 O] and form ammonium (NH.sub.4.sup.+) in the sterile water. A device for displacing the sterile water containing H.sub.2 [.sup.15 O] and NH.sub.4.sup.+ through a cation resin removes NH.sub.4.sup.+ from the sterile water. A device for combining the sterile water containing H.sub.2 [.sup.15 O] with a saline solution produces an injectable solution. Preferably, the apparatus includes a device for delivering the solution to a syringe for injection into a patient. Also, disclosed is a method for preparing H.sub.2 [.sup.15 O] in injectable form for use in Positron Emission Tomography in which the method neither requires isotopic exchange reaction nor application of high temperature.

  5. Apparatus and method for preparing oxygen-15 labeled water H{sub 2}[{sup 15}O] in an injectable form for use in positron emission tomography

    DOEpatents

    Ferrieri, R.A.; Schlyer, D.J.; Alexoff, D.

    1996-01-09

    A handling and processing apparatus is revealed for preparing Oxygen-15 labeled water (H{sub 2}[{sup 15}O]) in injectable form for use in Positron Emission Tomography from preferably H{sub 2}[{sup 15}O] produced by irradiating a flowing gas target of nitrogen and hydrogen. The apparatus includes a collector for receiving and directing a gas containing H{sub 2}[{sup 15}O] gas and impurities, mainly ammonia (NH{sub 3}) gas into sterile water to trap the H{sub 2}[{sup 15}O] and form ammonium (NH{sub 4}{sup +}) in the sterile water. A device for displacing the sterile water containing H{sub 2}[{sup 15}O] and NH{sub 4}{sup +} through a cation resin removes NH{sub 4}{sup +} from the sterile water. A device for combining the sterile water containing H{sub 2}[{sup 15}O] with a saline solution produces an injectable solution. Preferably, the apparatus includes a device for delivering the solution to a syringe for injection into a patient. Also, disclosed is a method for preparing H{sub 2}[{sup 15}O] in injectable form for use in Positron Emission Tomography in which the method neither requires isotopic exchange reaction nor application of high temperature. 7 figs.

  6. Optimization and validation of FePro cell labeling method.

    PubMed

    Janic, Branislava; Rad, Ali M; Jordan, Elaine K; Iskander, A S M; Ali, Md M; Varma, N Ravi S; Frank, Joseph A; Arbab, Ali S

    2009-06-11

    Current method to magnetically label cells using ferumoxides (Fe)-protamine (Pro) sulfate (FePro) is based on generating FePro complexes in a serum free media that are then incubated overnight with cells for the efficient labeling. However, this labeling technique requires long (>12-16 hours) incubation time and uses relatively high dose of Pro (5-6 microg/ml) that makes large extracellular FePro complexes. These complexes can be difficult to clean with simple cell washes and may create low signal intensity on T2* weighted MRI that is not desirable. The purpose of this study was to revise the current labeling method by using low dose of Pro and adding Fe and Pro directly to the cells before generating any FePro complexes. Human tumor glioma (U251) and human monocytic leukemia cell (THP-1) lines were used as model systems for attached and suspension cell types, respectively and dose dependent (Fe 25 to 100 microg/ml and Pro 0.75 to 3 microg/ml) and time dependent (2 to 48 h) labeling experiments were performed. Labeling efficiency and cell viability of these cells were assessed. Prussian blue staining revealed that more than 95% of cells were labeled. Intracellular iron concentration in U251 cells reached approximately 30-35 pg-iron/cell at 24 h when labeled with 100 microg/ml of Fe and 3 microg/ml of Pro. However, comparable labeling was observed after 4 h across the described FePro concentrations. Similarly, THP-1 cells achieved approximately 10 pg-iron/cell at 48 h when labeled with 100 microg/ml of Fe and 3 microg/ml of Pro. Again, comparable labeling was observed after 4 h for the described FePro concentrations. FePro labeling did not significantly affect cell viability. There was almost no extracellular FePro complexes observed after simple cell washes. To validate and to determine the effectiveness of the revised technique, human T-cells, human hematopoietic stem cells (hHSC), human bone marrow stromal cells (hMSC) and mouse neuronal stem cells (mNSC C17

  7. DNA-labeled clay: A sensitive new method for tracing particle transport

    USGS Publications Warehouse

    Mahler, B.J.; Winkler, M.; Bennett, P.; Hillis, D.M.

    1998-01-01

    The behavior of mobile colloids and sediment in most natural environments remains poorly understood, in part because characteristics of existing sediment tracers limit their wide-spread use. Here we describe the development of a new approach that uses a DNA-labeled montmorillonite clay as a highly sensitive and selective sediment tracer that can potentially characterize sediment and colloid transport in a wide variety of environments, including marine, wetland, ground-water, and atmospheric systems. Characteristics of DNA in natural systems render it unsuitable as an aqueous tracer but admirably suited as a label for tracing particulates. The DNA-labeled-clay approach, using techniques developed from molecular biology, has extremely low detection limits, very specific detection, and a virtually infinite number of tracer signatures. Furthermore, DNA-labeled clay has the same physical characteristics as the particles it is designed to trace, it is environmentally benign, and it can be relatively inexpensively produced and detected. Our initial results show that short (500 base pair) strands of synthetically produced DNA reversibly adsorb to both Na-montmorillonite and powdered silica surfaces via a magnesium bridge. The DNA-montmorillonite surface complexes are stable in calcium-bicarbonate spring waters for periods of up to 18 days and only slowly desorb to the aqueous phase, whereas the silica surface complex is stable only in distilled water. Both materials readily release the adsorbed DNA in dilute EDTA solutions for amplification by the polymerase chain reaction (PCR) and quantification. The stability of the DNA-labeled clay complex suggests that this material would be appropriate for use as an extremely sensitive sediment tracer for flow periods of as long as 2 weeks, and possibly longer.

  8. Validation of energy intake estimated from a food frequency questionnaire: a doubly labelled water study.

    PubMed

    Andersen, L Frost; Tomten, H; Haggarty, P; Løvø, A; Hustvedt, B-E

    2003-02-01

    The validation of dietary assessment methods is critical in the evaluation of the relation between dietary intake and health. The aim of this study was to assess the validity of a food frequency questionnaire by comparing energy intake with energy expenditure measured with the doubly labelled water method. Total energy expenditure was measured with the doubly labelled water (DLW) method during a 10 day period. Furthermore, the subjects filled in the food frequency questionnaire about 18-35 days after the DLW phase of the study was completed. Twenty-one healthy, non-pregnant females volunteered to participate in the study; only 17 subjects completed the study. The group energy intake was on average 10% lower than the energy expenditure, but the difference was not statistically significant. However, there was a wide range in reporting accuracy: seven subjects were identified as acceptable reporters, eight as under-reporters and two were identified as over-reporters. The width of the 95% confidence limits of agreement in a Bland and Altman plot for energy intake and energy expenditure varied from -5 to 3 MJ. The data showed that there was substantial variability in the accuracy of the food frequency questionnaire at the individual level. Furthermore, the results showed that the questionnaire was more accurate for groups than individuals.

  9. Volume-labeled nanoparticles and methods of preparation

    DOEpatents

    Wang, Wei; Gu, Baohua; Retterer, Scott T; Doktycz, Mitchel J

    2015-04-21

    Compositions comprising nanosized objects (i.e., nanoparticles) in which at least one observable marker, such as a radioisotope or fluorophore, is incorporated within the nanosized object. The nanosized objects include, for example, metal or semi-metal oxide (e.g., silica), quantum dot, noble metal, magnetic metal oxide, organic polymer, metal salt, and core-shell nanoparticles, wherein the label is incorporated within the nanoparticle or selectively in a metal oxide shell of a core-shell nanoparticle. Methods of preparing the volume-labeled nanoparticles are also described.

  10. Stable isotope labelling methods in mass spectrometry-based quantitative proteomics.

    PubMed

    Chahrour, Osama; Cobice, Diego; Malone, John

    2015-09-10

    Mass-spectrometry based proteomics has evolved as a promising technology over the last decade and is undergoing a dramatic development in a number of different areas, such as; mass spectrometric instrumentation, peptide identification algorithms and bioinformatic computational data analysis. The improved methodology allows quantitative measurement of relative or absolute protein amounts, which is essential for gaining insights into their functions and dynamics in biological systems. Several different strategies involving stable isotopes label (ICAT, ICPL, IDBEST, iTRAQ, TMT, IPTL, SILAC), label-free statistical assessment approaches (MRM, SWATH) and absolute quantification methods (AQUA) are possible, each having specific strengths and weaknesses. Inductively coupled plasma mass spectrometry (ICP-MS), which is still widely recognised as elemental detector, has recently emerged as a complementary technique to the previous methods. The new application area for ICP-MS is targeting the fast growing field of proteomics related research, allowing absolute protein quantification using suitable elemental based tags. This document describes the different stable isotope labelling methods which incorporate metabolic labelling in live cells, ICP-MS based detection and post-harvest chemical label tagging for protein quantification, in addition to summarising their pros and cons. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. A novel facile method of labeling octreotide with (18)F-fluorine.

    PubMed

    Laverman, Peter; McBride, William J; Sharkey, Robert M; Eek, Annemarie; Joosten, Lieke; Oyen, Wim J G; Goldenberg, David M; Boerman, Otto C

    2010-03-01

    Several methods have been developed to label peptides with (18)F. However, in general these are laborious and require a multistep synthesis. We present a facile method based on the chelation of (18)F-aluminum fluoride (Al(18)F) by 1,4,7-triazacyclononane-1,4,7-triacetic acid (NOTA). The method is characterized by the labeling of NOTA-octreotide (NOTA-d-Phe-cyclo[Cys-Phe-d-Trp-Lys-Thr-Cys]-Throl (MH(+) 1305) [IMP466]) with (18)F. Octreotide was conjugated with the NOTA chelate and labeled with (18)F in a 2-step, 1-pot method. The labeling procedure was optimized with regard to the labeling buffer, peptide, and aluminum concentration. Radiochemical yield, specific activity, in vitro stability, and receptor affinity were determined. Biodistribution of (18)F-IMP466 was studied in AR42J tumor-bearing mice and compared with that of (68)Ga-labeled IMP466. In addition, small-animal PET/CT images were acquired. IMP466 was labeled with Al(18)F in a single step with 50% yield. The labeled product was purified by high-performance liquid chromatography to remove unbound Al(18)F and unlabeled peptide. The radiolabeling, including purification, was performed in 45 min. The specific activity was 45,000 GBq/mmol, and the peptide was stable in serum for 4 h at 37 degrees C. Labeling was performed at pH 4.1 in sodium citrate, sodium acetate, 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, and 2-(N-morpholino)ethanesulfonic acid buffer and was optimal in sodium acetate buffer. The apparent 50% inhibitory concentration of the (19)F-labeled IMP466 determined on AR42J cells was 3.6 nM. Biodistribution studies at 2 h after injection showed a high tumor uptake of (18)F-IMP466 (28.3 +/- 5.2 percentage injected dose per gram [%ID/g]; tumor-to-blood ratio, 300 +/- 90), which could be blocked by an excess of unlabeled peptide (8.6 +/- 0.7 %ID/g), indicating that the accumulation in the tumor was receptor-mediated. Biodistribution of (68)Ga-IMP466 was similar to that of (18)F-IMP466. (18)F

  12. PRN 93-8: Labeling Statement Prohibiting Application to Water; Amendment to PR Notice 93-3

    EPA Pesticide Factsheets

    This notice adds one paragraph to P.R. Notice 93-3, which requested registrants to amend product labeling to include a new labeling statement prohibiting application of a pesticide to water for certain products.

  13. Inspection and Verification Guidance for WaterSense Labeled New Homes (Version 1.2)

    EPA Pesticide Factsheets

    A new home must be built by a WaterSense builder partner, certified by an EPA licensed certification provider, and meet all of the applicable criteria in the specification to become a WaterSense labeled new home.

  14. Colloid labelled with radionuclide and method

    DOEpatents

    Atcher, Robert W.; Hines, John J.

    1990-01-01

    A ferric hydroxide colloid having an alpha-emitting radionuclide essentially on the outer surfaces and a method of forming same. The method includes oxidizing a ferrous hydroxide to ferric hydroxide in the presence of a preselected radionuclide to form a colloid having the radionuclide on the outer surface thereof, and thereafter washing the colloid, and suspending the washed colloid in a suitable solution. The labelled colloid is useful in cancer therapy and for the treatment of inflamed joints.

  15. Development of methods to measure virus inactivation in fresh waters.

    PubMed Central

    Ward, R L; Winston, P E

    1985-01-01

    This study concerns the identification and correction of deficiencies in methods used to measure inactivation rates of enteric viruses seeded into environmental waters. It was found that viable microorganisms in an environmental water sample increased greatly after addition of small amounts of nutrients normally present in the unpurified seed virus preparation. This burst of microbial growth was not observed after seeding the water with purified virus. The use of radioactively labeled poliovirus revealed that high percentages of virus particles, sometimes greater than 99%, were lost through adherence to containers, especially in less turbid waters. This effect was partially overcome by the use of polypropylene containers and by the absence of movement during incubation. Adherence to containers clearly demonstrated the need for labeled viruses to monitor losses in this type of study. Loss of viral infectivity in samples found to occur during freezing was avoided by addition of broth. Finally, microbial contamination of the cell cultures during infectivity assays was overcome by the use of gentamicin and increased concentrations of penicillin, streptomycin, and amphotericin B. PMID:3004328

  16. Colloid labelled with radionuclide and method

    DOEpatents

    Atcher, R.W.; Hines, J.J.

    1990-11-13

    A ferric hydroxide colloid having an alpha-emitting radionuclide essentially on the outer surfaces and a method of forming same. The method includes oxidizing a ferrous hydroxide to ferric hydroxide in the presence of a preselected radionuclide to form a colloid having the radionuclide on the outer surface thereof, and thereafter washing the colloid, and suspending the washed colloid in a suitable solution. The labelled colloid is useful in cancer therapy and for the treatment of inflamed joints. No Drawings

  17. Using Power Spectrum Analysis to Evaluate 18O-Water Labeling Data Acquired from Low Resolution Mass Spectrometers

    PubMed Central

    Sadygov, Rovshan G.; Zhao, Yingxin; Haidacher, Sigmund J.; Starkey, Jonathan M.; Tilton, Ronald G.; Denner, Larry

    2010-01-01

    We describe a method for ratio estimations in 18O-water labeling experiments acquired from low resolution isotopically resolved data. The method is implemented in a software package specifically designed for use in experiments making use of zoom-scan mode data acquisition. Zoom-scan mode data allows commonly used ion trap mass spectrometers to attain isotopic resolution, which make them amenable to use in labeling schemes such as 18O-water labeling, but algorithms and software developed for high resolution instruments may not be appropriate for the lower resolution data acquired in zoom-scan mode. The use of power spectrum analysis is proposed as a general approach which may be uniquely suited to these data types. The software implementation uses power spectrum to remove high-frequency noise, and band-filter contributions from co-eluting species of differing charge states. From the elemental composition of a peptide sequence we generate theoretical isotope envelopes of heavy-light peptide pairs in five different ratios; these theoretical envelopes are correlated with the filtered experimental zoom scans. To automate peptide quantification in high-throughput experiments, we have implemented our approach in a computer program, MassXplorer. We demonstrate the application of MassXplorer to two model mixtures of known proteins, and to a complex mixture of mouse kidney cortical extract. Comparison with another algorithm for ratio estimations demonstrates the increased precision and automation of MassXplorer. PMID:20568695

  18. Microfabricated capillary electrophoresis chip and method for simultaneously detecting multiple redox labels

    DOEpatents

    Mathies, Richard A.; Singhal, Pankaj; Xie, Jin; Glazer, Alexander N.

    2002-01-01

    This invention relates to a microfabricated capillary electrophoresis chip for detecting multiple redox-active labels simultaneously using a matrix coding scheme and to a method of selectively labeling analytes for simultaneous electrochemical detection of multiple label-analyte conjugates after electrophoretic or chromatographic separation.

  19. Energy requirement assessed by doubly-labeled water method in patients with advanced amyotrophic lateral sclerosis managed by tracheotomy positive pressure ventilation.

    PubMed

    Ichihara, Noriko; Namba, Kazuyoshi; Ishikawa-Takata, Kazuko; Sekine, Kazunori; Takase, Mitsunori; Kamada, Yuko; Fujii, Seigo

    2012-10-01

    This study aimed to clarify the energy requirement in patients with amyotrophic lateral sclerosis (ALS) undergoing tracheostomy positive pressure ventilation with tracheostomy. Total energy expenditure (TEE) was measured in 10 hospitalized bedridden ALS patients using the doubly-labeled water (DLW) method. The mean TEE/day and TEE/fat- free mass estimated by DLW method were 934 ± 201 kcal/day and 34.8 ± 5.5 kcal/kg/day, respectively. The mean TEE/resting metabolic rate (RMR) was 0.85 when RMR was estimated by the Harris-Benedict equation, 0.91 by Dietary Reference Intake (DRI), and 0.97 by Ganpule's equation using fat-free mass (FFM). The ratios of TEE to measured RMR were 1.05, 1.15 and 1.23 in three patients. In conclusion, multiplying measured RMR by 1.1 to 1.2 is considered to be appropriate to estimate energy need. However, because it is difficult to measure RMR directly in a clinical setting, an appropriate equation for estimating RMR for ALS patient should be developed.

  20. Detection of Cu2+ in Water Based on Histidine-Gold Labeled Multiwalled Carbon Nanotube Electrochemical Sensor

    PubMed Central

    Zhu, Rilong; Zhou, Gangqiang; Tang, Fengxia; Wang, Yeyao

    2017-01-01

    Based on the strong interaction between histidine and copper ions and the signal enhancement effect of gold-labeling carbon nanotubes, an electrochemical sensor is established and used to measure copper ions in river water. In this study the results show that the concentrations of copper ion have well linear relationship with the peak current in the range of 10−11–10−7 mol/L, and the limit of detection is 10−12 mol/L. When using this method to detect copper ions in the Xiangjiang River, the test results are consistent with the atomic absorption method. This study shows that the sensor is convenient to be used in daily monitoring of copper ions in river water. PMID:28408929

  1. Systematic review: reliability of compendia methods for off-label oncology indications.

    PubMed

    Abernethy, Amy P; Raman, Gowri; Balk, Ethan M; Hammond, Julia M; Orlando, Lori A; Wheeler, Jane L; Lau, Joseph; McCrory, Douglas C

    2009-03-03

    The Centers for Medicare & Medicaid Services limit coverage of cancer drugs for off-label indications to indications listed in specified compendia. To assess whether compendia provide comprehensive, research-based, and timely information for off-label prescribing in oncology. 6 drug compendia, English-language literature searches of MEDLINE and the Cochrane Central Register of Controlled Trials from 2006 and 2008, and American Society of Clinical Oncology annual meeting abstracts from 2004 to 2007. Data Assessment: The compendia's stated methods, literature related to off-label indications of 14 cancer drugs in 2006, updated literature related to 1 off-label indication between 2006 and 2008, and completeness of compendia content and citations were assessed. The compendia's stated methods varied greatly from their actual practices. Compendia cited little of the available evidence, often neither the most recent nor that of highest methodological quality. Compendia differed in evidence cited, terminology, detail, presentation, and referencing. For the 14 off-label indications studied, the compendia differed in the indications included and whether and how they recommended particular agents for particular types of cancer. Update schedules varied, and documentation practices made it difficult to determine whether and when compendia content was updated. For 1 indication, compendia citations did not increase between 2006 and 2008 despite newly published articles. The 2006 analysis was limited to 14 off-label indications; the 2008 update examined 1 indication. Only off-label indications for cancer drugs were included, and results cannot be generalized to noncancer drugs or indications. Oncologists rely on compendia for up-to-date access to evidence and reimbursement information for off-label indications. Current compendia lack transparency, cite little current evidence, and lack systematic methods to review or update evidence.

  2. Foraging flights of the white-tailed tropicbird (Phaethon lepturus): Radiotracking and doubly-labelled water

    USGS Publications Warehouse

    Pennycuick, C.J.; Shaffner, F.C.; Fuller, M.R.; Obrecht, H.H.; Sternberg, L.

    1990-01-01

    Radiotracking transmitters were fitted to White-tailed Tropicbirds nesting at Culebra, Puerto Rico. Foragers were located by light aircraft out to 89 km SSW of the nesting colony, over a deep-water foraging area south of Vieques Island, Puerto Rico and west of St Croix, U. S. Virgin Islands. Two birds were followed out to 176 km NNW from the colony, over the Puerto Rico Trench, but these did not subsequently return. Foragers carrying radio transmitters performed similarly to those without, in terms of duration of absence from the colony, and mass of food brought for the chick. However, measuremetns of energy consumption by the doubly labelled water method indicated that birds with transmitters consumed significantly more energy than those without.

  3. Improved microautoradiographic method to determine individual microorganisms active in substrate uptake in natural waters.

    PubMed

    Tabor, P S; Neihof, R A

    1982-10-01

    We report a method which combines epifluorescence microscopy and microautoradiography to determine both the total number of microorganisms in natural water populations and those individual organisms active in the uptake of specific substrates. After incubation with H-labeled substrate, the sample is filtered and, while still on the filter, mounted directly in a film of autoradiographic emulsion on a microscope slide. The microautoradiogram is processed and stained with acridine orange, and, subsequently, the filter is removed before microscopic observation. This novel preparation resulted in increased accuracy in direct counts made from the autoradiogram, improved sensitivity in the recognition of uptake-active (H-labeled) organisms, and enumeration of a significantly greater number of labeled organisms compared with corresponding samples prepared by a previously reported method.

  4. Assay for vitamin B12 absorption and method of making labeled vitamin B12

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, Peter J; Dueker, Stephen; Miller, Joshua

    2012-06-19

    The invention provides methods for labeling vitamin B12 with .sup.14C, .sup.13C, tritium, and deuterium. When radioisotopes are used, the invention provides for methods of labeling B12 with high specific activity. The invention also provides labeled vitamin B12 compositions made in accordance with the invention.

  5. Method of making colloid labeled with radionuclide

    DOEpatents

    Atcher, Robert W.; Hines, John J.

    1991-01-01

    A ferric hydroxide colloid having an alpha-emitting radionuclide essentially on the outer surfaces and a method of forming same. The method includes oxidizing a ferrous hydroxide to ferric hydroxide in the presence of a preselected radionuclide to form a colloid having the radionuclide on the outer surface thereof, and thereafter washing the colloid, and suspending the washed colloid in a suitable solution. The labelled colloid is useful in cancer therapy and for the treatment of inflamed joints.

  6. Developments in label-free microfluidic methods for single-cell analysis and sorting.

    PubMed

    Carey, Thomas R; Cotner, Kristen L; Li, Brian; Sohn, Lydia L

    2018-04-24

    Advancements in microfluidic technologies have led to the development of many new tools for both the characterization and sorting of single cells without the need for exogenous labels. Label-free microfluidics reduce the preparation time, reagents needed, and cost of conventional methods based on fluorescent or magnetic labels. Furthermore, these devices enable analysis of cell properties such as mechanical phenotype and dielectric parameters that cannot be characterized with traditional labels. Some of the most promising technologies for current and future development toward label-free, single-cell analysis and sorting include electronic sensors such as Coulter counters and electrical impedance cytometry; deformation analysis using optical traps and deformation cytometry; hydrodynamic sorting such as deterministic lateral displacement, inertial focusing, and microvortex trapping; and acoustic sorting using traveling or standing surface acoustic waves. These label-free microfluidic methods have been used to screen, sort, and analyze cells for a wide range of biomedical and clinical applications, including cell cycle monitoring, rapid complete blood counts, cancer diagnosis, metastatic progression monitoring, HIV and parasite detection, circulating tumor cell isolation, and point-of-care diagnostics. Because of the versatility of label-free methods for characterization and sorting, the low-cost nature of microfluidics, and the rapid prototyping capabilities of modern microfabrication, we expect this class of technology to continue to be an area of high research interest going forward. New developments in this field will contribute to the ongoing paradigm shift in cell analysis and sorting technologies toward label-free microfluidic devices, enabling new capabilities in biomedical research tools as well as clinical diagnostics. This article is categorized under: Diagnostic Tools > Biosensing Diagnostic Tools > Diagnostic Nanodevices. © 2018 Wiley Periodicals, Inc.

  7. Couple Graph Based Label Propagation Method for Hyperspectral Remote Sensing Data Classification

    NASA Astrophysics Data System (ADS)

    Wang, X. P.; Hu, Y.; Chen, J.

    2018-04-01

    Graph based semi-supervised classification method are widely used for hyperspectral image classification. We present a couple graph based label propagation method, which contains both the adjacency graph and the similar graph. We propose to construct the similar graph by using the similar probability, which utilize the label similarity among examples probably. The adjacency graph was utilized by a common manifold learning method, which has effective improve the classification accuracy of hyperspectral data. The experiments indicate that the couple graph Laplacian which unite both the adjacency graph and the similar graph, produce superior classification results than other manifold Learning based graph Laplacian and Sparse representation based graph Laplacian in label propagation framework.

  8. Improved 68 Ga-labeling method using ethanol addition: Application to the α-helical peptide DOTA-FAMP.

    PubMed

    Hasegawa, Koki; Kawachi, Emi; Uehara, Yoshinari; Yoshida, Tsuyoshi; Imaizumi, Satoshi; Ogawa, Masahiro; Miura, Shin-Ichiro; Saku, Keijiro

    2017-01-01

    We examined the 68 Ga labeling of the α-helical peptide, DOTA-FAMP, and evaluated conformational changes during radiolabeling. 68 Ga-DOTA-FAMP is a positron emission tomography probe candidate for atherosclerotic plaques. The labeling yield achieved by Zhernosekov's method (using acetone for 68 Ga purification) was compared with that achieved by the original and 2 modified Mueller's methods (using NaCl solution). Modified method I involves desalting the 68 Ga prior to labeling, and modified method II involves the inclusion of ethanol in the labeling solution. The labeling yield using Zhernosekov's method was 62% ± 5.4%. In comparison, Mueller's original method gave 8.9% ± 1.7%. Modified method I gave a slight improvement of 32% ± 2.1%. Modified method II further increased the yield to 66% ± 3.4%. Conformational changes were determined by circular dichroism spectroscopy, revealing that these differences could be attributed to conformational changes. Heat treatment affects peptide conformation, which leads to aggregation and decreases the labeling yield. Mueller's method is simpler, but harsh conditions preclude its application to biomolecules. To suppress aggregation, we included a desalting process and added ethanol in the labeling solution. These changes significantly improved the labeling yield. Before use for imaging, conformational changes of biomolecules during radiolabeling should be evaluated by circular dichroism spectroscopy to ensure the homogeneity of the labeled product. Copyright © 2016 John Wiley & Sons, Ltd.

  9. Improved Microautoradiographic Method to Determine Individual Microorganisms Active in Substrate Uptake in Natural Waters

    PubMed Central

    Tabor, Paul S.; Neihof, Rex A.

    1982-01-01

    We report a method which combines epifluorescence microscopy and microautoradiography to determine both the total number of microorganisms in natural water populations and those individual organisms active in the uptake of specific substrates. After incubation with 3H-labeled substrate, the sample is filtered and, while still on the filter, mounted directly in a film of autoradiographic emulsion on a microscope slide. The microautoradiogram is processed and stained with acridine orange, and, subsequently, the filter is removed before microscopic observation. This novel preparation resulted in increased accuracy in direct counts made from the autoradiogram, improved sensitivity in the recognition of uptake-active (3H-labeled) organisms, and enumeration of a significantly greater number of labeled organisms compared with corresponding samples prepared by a previously reported method. Images PMID:16346120

  10. 78 FR 78305 - Energy and Water Use Labeling for Consumer Products Under the Energy Policy and Conservation Act...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-26

    ... FEDERAL TRADE COMMISSION 16 CFR Part 305 [3084-AB15] Energy and Water Use Labeling for Consumer Products Under the Energy Policy and Conservation Act (``Energy Labeling Rule'') AGENCY: Federal Trade... to the Energy Labeling Rule (``Rule'') to require a new Department of Energy (DOE) test procedure for...

  11. SIMPLE: a sequential immunoperoxidase labeling and erasing method.

    PubMed

    Glass, George; Papin, Jason A; Mandell, James W

    2009-10-01

    The ability to simultaneously visualize expression of multiple antigens in cells and tissues can provide powerful insights into cellular and organismal biology. However, standard methods are limited to the use of just two or three simultaneous probes and have not been widely adopted for routine use in paraffin-embedded tissue. We have developed a novel approach called sequential immunoperoxidase labeling and erasing (SIMPLE) that enables the simultaneous visualization of at least five markers within a single tissue section. Utilizing the alcohol-soluble peroxidase substrate 3-amino-9-ethylcarbazole, combined with a rapid non-destructive method for antibody-antigen dissociation, we demonstrate the ability to erase the results of a single immunohistochemical stain while preserving tissue antigenicity for repeated rounds of labeling. SIMPLE is greatly facilitated by the use of a whole-slide scanner, which can capture the results of each sequential stain without any information loss.

  12. Preparation of 99mTc-TRODAT-1 with high labeling yield in boiling water bath: a new formulation.

    PubMed

    Erfani, Mostafa; Shafiei, Mohammad

    2014-04-01

    A new formulation for preparation of (99m)Tc-labeled tropane derivative, (99m)Tc-TRODAT-1, which is useful as a potential CNS dopamine transporter imaging agent, was evaluated and characterized. Preparation of (99m)Tc-TRODAT-1 was attained previously by a formulation in which vial has to be autoclaved at 121 °C for 30 min. It is highly desirable to further improve the preparation method by developing a simplified one vial formulation which will be labeled in boiling water bath (95 °C) for 15 min and a high labeling yield will be achieved. A formulation contained 10 μg of TRODAT-1, 20 μg tricine, 40 μg SnCl2 and 20mg manitol was prepared. Labeling was performed at 95 °C for 15 min and radiochemical analysis involved ITLC and HPLC methods. The stability of radioconjugate was checked in the presence of human serum at 37 °C up to 24h. (99m)Tc-TRODAT-1 was prepared with a radiochemical purity of more than 95% and specific activity of 64.3 MBq/nmol. Biodistribution studies of this new formulation in rats revealed similar regional brain distribution as compared with those obtained with the previous preparation in which brain uptake was high in striatum and striatum to cerebellum ratio was high. Requiring no autoclave facility for labeling, this new formulation will significantly improve the using feasibility of this radiopharmaceutical in clinic. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Inulin determination for food labeling.

    PubMed

    Zuleta, A; Sambucetti, M E

    2001-10-01

    Inulin and oligofructose exhibit valuable nutritional and functional attributes, so they are used as supplements as soluble fiber or as macronutrient substitutes. As classic analytical methods for dietary fiber measurement are not effective, several specific methods have been proposed. These methods measure total fructans and are based on one or more enzymatic sample treatments and determination of released sugars. To determine inulin for labeling purposes, we developed an easy and rapid anion-exchange high-performance liquid chromatography (HPLC) method following water extraction of inulin. HPLC conditions included an Aminex HPX- 87C column (Bio-Rad), deionized water at 85 degrees C as the mobile phase and a refractive index detector. The tested foods included tailor-made food products containing known amounts of inulin and commercial products (cookies, milk, ice creams, cheese, and cereal bars). The average recovery was 97%, and the coefficient of variation ranged from 1.1 to 5% in the food matrixes. The obtained results showed that this method provides an easier, faster and cheaper alternative than previous techniques for determining inulin with enough accuracy and precision for routine labeling purposes by direct determination of inulin by HPLC with refractive index detection.

  14. Use of stable isotope-labelled cells to identify active grazers of picocyanobacteria in ocean surface waters.

    PubMed

    Frias-Lopez, Jorge; Thompson, Anne; Waldbauer, Jacob; Chisholm, Sallie W

    2009-02-01

    Prochlorococcus and Synechococcus are the two most abundant marine cyanobacteria. They represent a significant fraction of the total primary production of the world oceans and comprise a major fraction of the prey biomass available to phagotrophic protists. Despite relatively rapid growth rates, picocyanobacterial cell densities in open-ocean surface waters remain fairly constant, implying steady mortality due to viral infection and consumption by predators. There have been several studies on grazing by specific protists on Prochlorococcus and Synechococcus in culture, and of cell loss rates due to overall grazing in the field. However, the specific sources of mortality of these primary producers in the wild remain unknown. Here, we use a modification of the RNA stable isotope probing technique (RNA-SIP), which involves adding labelled cells to natural seawater, to identify active predators that are specifically consuming Prochlorococcus and Synechococcus in the surface waters of the Pacific Ocean. Four major groups were identified as having their 18S rRNA highly labelled: Prymnesiophyceae (Haptophyta), Dictyochophyceae (Stramenopiles), Bolidomonas (Stramenopiles) and Dinoflagellata (Alveolata). For the first three of these, the closest relative of the sequences identified was a photosynthetic organism, indicating the presence of mixotrophs among picocyanobacterial predators. We conclude that the use of RNA-SIP is a useful method to identity specific predators for picocyanobacteria in situ, and that the method could possibly be used to identify other bacterial predators important in the microbial food-web.

  15. Psychosocial predictors of energy underreporting in a large doubly labeled water study.

    PubMed

    Tooze, Janet A; Subar, Amy F; Thompson, Frances E; Troiano, Richard; Schatzkin, Arthur; Kipnis, Victor

    2004-05-01

    Underreporting of energy intake is associated with self-reported diet measures and appears to be selective according to personal characteristics. Doubly labeled water is an unbiased reference biomarker for energy intake that may be used to assess underreporting. Our objective was to determine which factors are associated with underreporting of energy intake on food-frequency questionnaires (FFQs) and 24-h dietary recalls (24HRs). The study participants were 484 men and women aged 40-69 y who resided in Montgomery County, MD. Using the doubly labeled water method to measure total energy expenditure, we considered numerous psychosocial, lifestyle, and sociodemographic factors in multiple logistic regression models for prediction of the probability of underreporting on the FFQ and 24HR. In the FFQ models, fear of negative evaluation, weight-loss history, and percentage of energy from fat were the best predictors of underreporting in women (R(2) = 0.09); body mass index, comparison of activity level with that of others of the same sex and age, and eating frequency were the best predictors in men (R(2) = 0.10). In the 24HR models, social desirability, fear of negative evaluation, body mass index, percentage of energy from fat, usual activity, and variability in number of meals per day were the best predictors of underreporting in women (R(2) = 0.22); social desirability, dietary restraint, body mass index, eating frequency, dieting history, and education were the best predictors in men (R(2) = 0.25). Although the final models were significantly related to underreporting on both the FFQ and the 24HR, the amount of variation explained by these models was relatively low, especially for the FFQ.

  16. A label distance maximum-based classifier for multi-label learning.

    PubMed

    Liu, Xiaoli; Bao, Hang; Zhao, Dazhe; Cao, Peng

    2015-01-01

    Multi-label classification is useful in many bioinformatics tasks such as gene function prediction and protein site localization. This paper presents an improved neural network algorithm, Max Label Distance Back Propagation Algorithm for Multi-Label Classification. The method was formulated by modifying the total error function of the standard BP by adding a penalty term, which was realized by maximizing the distance between the positive and negative labels. Extensive experiments were conducted to compare this method against state-of-the-art multi-label methods on three popular bioinformatic benchmark datasets. The results illustrated that this proposed method is more effective for bioinformatic multi-label classification compared to commonly used techniques.

  17. Dilution space ratio of 2H and 18O of doubly labeled water method in humans.

    PubMed

    Sagayama, Hiroyuki; Yamada, Yosuke; Racine, Natalie M; Shriver, Timothy C; Schoeller, Dale A

    2016-06-01

    Variation of the dilution space ratio (Nd/No) between deuterium ((2)H) and oxygen-18 ((18)O) impacts the calculation of total energy expenditure (TEE) by doubly labeled water (DLW). Our aim was to examine the physiological and methodological sources of variation of Nd/No in humans. We analyzed data from 2,297 humans (0.25-89 yr old). This included the variables Nd/No, total body water, TEE, body mass index (BMI), and percent body fat (%fat). To differentiate between physiologic and methodologic sources of variation, the urine samples from 54 subjects were divided and blinded and analyzed separately, and repeated DLW dosing was performed in an additional 55 participants after 6 mo. Sex, BMI, and %fat did not significantly affect Nd/No, for which the interindividual SD was 0.017. The measurement error from the duplicate urine sample sets was 0.010, and intraindividual SD of Nd/No in repeats experiments was 0.013. An additional SD of 0.008 was contributed by calibration of the DLW dose water. The variation of measured Nd/No in humans was distributed within a small range and measurement error accounted for 68% of this variation. There was no evidence that Nd/No differed with respect to sex, BMI, and age between 1 and 80 yr, and thus use of a constant value is suggested to minimize the effect of stable isotope analysis error on calculation of TEE in the DLW studies in humans. Based on a review of 103 publications, the average dilution space ratio is 1.036 for individuals between 1 and 80 yr of age. Copyright © 2016 the American Physiological Society.

  18. A new method for the labelling of proteins with radioactive arsenic isotopes

    NASA Astrophysics Data System (ADS)

    Jennewein, M.; Hermanne, A.; Mason, R. P.; Thorpe, P. E.; Rösch, F.

    2006-12-01

    Radioarsenic labelled radiopharmaceuticals could be a valuable asset to positron emission tomography. In particular, the long half-lives of 72As ( T=26 h) and 74As ( T=17.8 d) allow to investigate slow physiological or metabolical processes, like the enrichment and distribution of monoclonal antibodies (mab) in tumour tissue. In this work, a new method for the labelling of proteins with various radioactive arsenic isotopes was developed. For this purpose, two proteins, namely a chimeric IgG 3 monoclonal antibody, ch3G4, directed against anionic phospholipids, and Rituxan (Rituximab), were labelled as a proof of principle with no-carrier-added radioarsenic isotopes ( 74As and 77As). The developed labelling chemistry gives high yields (>99.9%), is reliable and could easily be transferred to automated labelling systems in a clinical environment. At least for the mab used in this work, this route of radioarsenic labelling does not affect the immunoreactivity of the product. The arsenic label stays stable for up to 72 h at the molecular mass of the monoclonal antibody, which is in particular relevant to follow the pharmacology and pharmacokinetics of the labelled mab for several days.

  19. A novel label-free fluorescence assay for one-step sensitive detection of Hg2+ in environmental drinking water samples

    NASA Astrophysics Data System (ADS)

    Li, Ya; Liu, Nan; Liu, Hui; Wang, Yu; Hao, Yuwei; Ma, Xinhua; Li, Xiaoli; Huo, Yapeng; Lu, Jiahai; Tang, Shuge; Wang, Caiqin; Zhang, Yinhong; Gao, Zhixian

    2017-04-01

    A novel label-free fluorescence assay for detection of Hg2+ was developed based on the Hg2+-binding single-stranded DNA (ssDNA) and SYBR Green I (SG I). Differences from other assays, the designed rich-thymine (T) ssDNA probe without fluorescent labelling can be rapidly formed a T-Hg2+-T complex and folded into a stable hairpin structure in the presence of Hg2+ in environmental drinking water samples by facilitating fluorescence increase through intercalating with SG I in one-step. In the assay, the fluorescence signal can be directly obtained without additional incubation within 1 min. The dynamic quantitative working ranges was 5-1000 nM, the determination coefficients were satisfied by optimization of the reaction conditions. The lowest detection limit of Hg2+ was 3 nM which is well below the standard of U.S. Environmental Protection Agency. This method was highly specific for detecting of Hg2+ without being affected by other possible interfering ions from different background compositions of water samples. The recoveries of Hg2+ spiked in these samples were 95.05-103.51%. The proposed method is more viable, low-costing and simple for operation in field detection than the other methods with great potentials, such as emergency disposal, environmental monitoring, surveillance and supporting of ecological risk assessment and management.

  20. Oligonucleotide labeling methods. 3. Direct labeling of oligonucleotides employing a novel, non-nucleosidic, 2-aminobutyl-1,3-propanediol backbone.

    PubMed Central

    Nelson, P S; Kent, M; Muthini, S

    1992-01-01

    Novel CE-phosphoramidite (7a-e) and CPG (8a, c, d, e) reagents have been prepared from a unique 2-aminobutyl-1,3-propanediol backbone. The reagents have been used to directly label oligonucleotides with fluorescein, acridine, and biotin via automated DNA synthesis. The versatile 2-aminobutyl-1,3-propanediol backbone allows for labeling at any position (5', internal, and 3') during solid phase oligonucleotide synthesis. Multiple labels can be achieved by repetitive coupling cycles. Furthermore, the 3-carbon atom internucleotide phosphate distance is retained when inserted internally. Using this method, individual oligonucleotides possessing two and three different reporter molecules have been prepared. PMID:1475185

  1. Systematic Comparison of Label-Free, Metabolic Labeling, and Isobaric Chemical Labeling for Quantitative Proteomics on LTQ Orbitrap Velos

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Zhou; Adams, Rachel M; Chourey, Karuna

    2012-01-01

    A variety of quantitative proteomics methods have been developed, including label-free, metabolic labeling, and isobaric chemical labeling using iTRAQ or TMT. Here, these methods were compared in terms of the depth of proteome coverage, quantification accuracy, precision, and reproducibility using a high-performance hybrid mass spectrometer, LTQ Orbitrap Velos. Our results show that (1) the spectral counting method provides the deepest proteome coverage for identification, but its quantification performance is worse than labeling-based approaches, especially the quantification reproducibility; (2) metabolic labeling and isobaric chemical labeling are capable of accurate, precise, and reproducible quantification and provide deep proteome coverage for quantification. Isobaricmore » chemical labeling surpasses metabolic labeling in terms of quantification precision and reproducibility; (3) iTRAQ and TMT perform similarly in all aspects compared in the current study using a CID-HCD dual scan configuration. Based on the unique advantages of each method, we provide guidance for selection of the appropriate method for a quantitative proteomics study.« less

  2. A Low-Storage-Consumption XML Labeling Method for Efficient Structural Information Extraction

    NASA Astrophysics Data System (ADS)

    Liang, Wenxin; Takahashi, Akihiro; Yokota, Haruo

    Recently, labeling methods to extract and reconstruct the structural information of XML data, which are important for many applications such as XPath query and keyword search, are becoming more attractive. To achieve efficient structural information extraction, in this paper we propose C-DO-VLEI code, a novel update-friendly bit-vector encoding scheme, based on register-length bit operations combining with the properties of Dewey Order numbers, which cannot be implemented in other relevant existing schemes such as ORDPATH. Meanwhile, the proposed method also achieves lower storage consumption because it does not require either prefix schema or any reserved codes for node insertion. We performed experiments to evaluate and compare the performance and storage consumption of the proposed method with those of the ORDPATH method. Experimental results show that the execution times for extracting depth information and parent node labels using the C-DO-VLEI code are about 25% and 15% less, respectively, and the average label size using the C-DO-VLEI code is about 24% smaller, comparing with ORDPATH.

  3. A Method to Constrain Genome-Scale Models with 13C Labeling Data

    PubMed Central

    García Martín, Héctor; Kumar, Vinay Satish; Weaver, Daniel; Ghosh, Amit; Chubukov, Victor; Mukhopadhyay, Aindrila; Arkin, Adam; Keasling, Jay D.

    2015-01-01

    Current limitations in quantitatively predicting biological behavior hinder our efforts to engineer biological systems to produce biofuels and other desired chemicals. Here, we present a new method for calculating metabolic fluxes, key targets in metabolic engineering, that incorporates data from 13C labeling experiments and genome-scale models. The data from 13C labeling experiments provide strong flux constraints that eliminate the need to assume an evolutionary optimization principle such as the growth rate optimization assumption used in Flux Balance Analysis (FBA). This effective constraining is achieved by making the simple but biologically relevant assumption that flux flows from core to peripheral metabolism and does not flow back. The new method is significantly more robust than FBA with respect to errors in genome-scale model reconstruction. Furthermore, it can provide a comprehensive picture of metabolite balancing and predictions for unmeasured extracellular fluxes as constrained by 13C labeling data. A comparison shows that the results of this new method are similar to those found through 13C Metabolic Flux Analysis (13C MFA) for central carbon metabolism but, additionally, it provides flux estimates for peripheral metabolism. The extra validation gained by matching 48 relative labeling measurements is used to identify where and why several existing COnstraint Based Reconstruction and Analysis (COBRA) flux prediction algorithms fail. We demonstrate how to use this knowledge to refine these methods and improve their predictive capabilities. This method provides a reliable base upon which to improve the design of biological systems. PMID:26379153

  4. An Efficient Site-Specific Method for Irreversible Covalent Labeling of Proteins with a Fluorophore.

    PubMed

    Liu, Jiaquan; Hanne, Jeungphill; Britton, Brooke M; Shoffner, Matthew; Albers, Aaron E; Bennett, Jared; Zatezalo, Rachel; Barfield, Robyn; Rabuka, David; Lee, Jong-Bong; Fishel, Richard

    2015-11-19

    Fluorophore labeling of proteins while preserving native functions is essential for bulk Förster resonance energy transfer (FRET) interaction and single molecule imaging analysis. Here we describe a versatile, efficient, specific, irreversible, gentle and low-cost method for labeling proteins with fluorophores that appears substantially more robust than a similar but chemically distinct procedure. The method employs the controlled enzymatic conversion of a central Cys to a reactive formylglycine (fGly) aldehyde within a six amino acid Formylglycine Generating Enzyme (FGE) recognition sequence in vitro. The fluorophore is then irreversibly linked to the fGly residue using a Hydrazinyl-Iso-Pictet-Spengler (HIPS) ligation reaction. We demonstrate the robust large-scale fluorophore labeling and purification of E.coli (Ec) mismatch repair (MMR) components. Fluorophore labeling did not alter the native functions of these MMR proteins in vitro or in singulo. Because the FGE recognition sequence is easily portable, FGE-HIPS fluorophore-labeling may be easily extended to other proteins.

  5. Minnesota leisure time activity questionnaire and doubly labeled water in adolescents.

    PubMed

    Slinde, Frode; Arvidsson, Daniel; Sjöberg, Agneta; Rossander-Hulthén, Lena

    2003-11-01

    To validate the energy expenditure estimated from The Minnesota Leisure Time Physical Activity Questionnaire (MLTPAQ) with total energy expenditure (TEE) measured by doubly labeled water (DLW), and to present and examine the validity of an extended version of the MLTPAQ with additional questions about inactivity during leisure time (eMLTPAQ), in a sample of Swedish 15-yr-old adolescents. Thirty-five 15-yr-old adolescents were interviewed using the eMLTPAQ. In addition to anthropometry, indirect calorimetry was measured to assess basal metabolic rate, and TEE was assessed by the DLW method over a 14-d period. Energy expenditure calculated from MLTPAQ correlated well with TEEDLW (r=0.49, P<0.01), and the correlation increased when including questions about inactivity (r=0.73, P<0.01). However, eMLTPAQ underestimated TEE in 34 of the 35 students, with a mean difference between the methods of 2.8 MJ.d(-1) (95% limits of agreement: -0.1 to 5.6 MJ.d(-1)), which mainly was explained by a relative high intensity in the time which remained unreported. eMLTPAQ is valid in ranking adolescents energy expenditure and in describing patterns of leisure time physical activities.

  6. Simple SPION Incubation as an Efficient Intracellular Labeling Method for Tracking Neural Progenitor Cells Using MRI

    PubMed Central

    D. M., Jayaseema; Lai, Jiann-Shiun; Hueng, Dueng-Yuan; Chang, Chen

    2013-01-01

    Cellular magnetic resonance imaging (MRI) has been well-established for tracking neural progenitor cells (NPC). Superparamagnetic iron oxide nanoparticles (SPIONs) approved for clinical application are the most common agents used for labeling. Conventionally, transfection agents (TAs) were added with SPIONs to facilitate cell labeling because SPIONs in the native unmodified form were deemed inefficient for intracellular labeling. However, compelling evidence also shows that simple SPION incubation is not invariably ineffective. The labeling efficiency can be improved by prolonged incubation and elevated iron doses. The goal of the present study was to establish simple SPION incubation as an efficient intracellular labeling method. To this end, NPCs derived from the neonatal subventricular zone were incubated with SPIONs (Feridex®) and then evaluated in vitro with regard to the labeling efficiency and biological functions. The results showed that, following 48 hours of incubation at 75 µg/ml, nearly all NPCs exhibited visible SPION intake. Evidence from light microscopy, electron microscopy, chemical analysis, and magnetic resonance imaging confirmed the effectiveness of the labeling. Additionally, biological assays showed that the labeled NPCs exhibited unaffected viability, oxidative stress, apoptosis and differentiation. In the demonstrated in vivo cellular MRI experiment, the hypointensities representing the SPION labeled NPCs remained observable throughout the entire tracking period. The findings indicate that simple SPION incubation without the addition of TAs is an efficient intracellular magnetic labeling method. This simple approach may be considered as an alternative approach to the mainstream labeling method that involves the use of TAs. PMID:23468856

  7. LC/MS Method for the Determination of Stable Isotope Labeled Promethazine in Human Plasma

    NASA Technical Reports Server (NTRS)

    Zuwei, Wang; Boyd, Jason; Berens, Kurt L.; Putcha, Lakshmi

    2004-01-01

    Promethazine (PMZ) is taken by astronauts orally (PO), intramuscularly (IM) or rectally (PR) for space motion sickness. LC/MS method was developed with off-line solid phase extraction to measure plasma concentrations of PMZ given as stable isotope-labeled (SIL) formulations by the three different routes of administration simultaneously. Samples (0.5ml) were loaded on to Waters Oasis HLB co-polymer cartridges and eluted with 1.0 mL methanol. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 6 min. Acetonitrile/ ammonium acetate (30 mM) in water (3:2, v/v), pH 5.6 plus or minus 0.1, was used as the mobile phase for separation. Concentrations of PMZ, PMZ-d4 and PMZ-d7 and chlorpromazine (internal standard) were determined using a Micromass ZMD single quadrupole mass spectrometer with Electrospray Ionization (ESI). ESI mass spectra were acquired in positive ion mode with selected ion monitoring of [M+ H]dot plus. The method is rapid, reproducible and the assay specific parameters are listed in a table. A novel, sensitive and specific method for the measurement of PMZ and SIL PMZ in human plasma is reported.

  8. An easy-to-use semiquantitative food record validated for energy intake by using doubly labelled water technique.

    PubMed

    Koebnick, C; Wagner, K; Thielecke, F; Dieter, G; Höhne, A; Franke, A; Garcia, A L; Meyer, H; Hoffmann, I; Leitzmann, P; Trippo, U; Zunft, H J F

    2005-09-01

    Estimating dietary intake is important for both epidemiological and clinical studies, but often lacks accuracy. To investigate the accuracy and validity of energy intake estimated by an easy-to-use semiquantitative food record (EI(SQFR)) compared to total energy expenditure (TEE) estimated by doubly labelled water technique (EE(DLW)). TEE was measured in 29 nonobese subjects using the doubly labelled water method over a period of 14 days. Within this period, subjects reported their food consumption by a newly developed semiquantitative food record for 4 consecutive days. Energy intake was calculated using the German Food Code and Nutrition Data Base BLS II.3. A good correlation was observed between EI(SQFR) and EE(DLW) (r = 0.685, P < 0.001). The mean difference between EI(SQFR) and EE(DLW) was -1.7+/-2.6 MJ/day (-14+/-21%, P = 0.002). An underestimation of EI(SQFR) <10% was observed in nine subjects (31%), of 10-20% in six subjects (21%), and of >20% in nine subjects (31%). In five subjects (17%), an overestimation of EI(SQFR) was observed. The easy-to-use semiquantitative food record provided good estimates of EI in free-living and nonobese adults without prior detailed verbal instructions. The presented food record has limitations regarding accuracy at the individual level.

  9. Pulse-labelling trees to study carbon allocation dynamics: a review of methods, current knowledge and future prospects.

    PubMed

    Epron, Daniel; Bahn, Michael; Derrien, Delphine; Lattanzi, Fernando Alfredo; Pumpanen, Jukka; Gessler, Arthur; Högberg, Peter; Maillard, Pascale; Dannoura, Masako; Gérant, Dominique; Buchmann, Nina

    2012-06-01

    Pulse-labelling of trees with stable or radioactive carbon (C) isotopes offers the unique opportunity to trace the fate of labelled CO(2) into the tree and its release to the soil and the atmosphere. Thus, pulse-labelling enables the quantification of C partitioning in forests and the assessment of the role of partitioning in tree growth, resource acquisition and C sequestration. However, this is associated with challenges as regards the choice of a tracer, the methods of tracing labelled C in tree and soil compartments and the quantitative analysis of C dynamics. Based on data from 47 studies, the rate of transfer differs between broadleaved and coniferous species and decreases as temperature and soil water content decrease. Labelled C is rapidly transferred belowground-within a few days or less-and this transfer is slowed down by drought. Half-lives of labelled C in phloem sap (transfer pool) and in mature leaves (source organs) are short, while those of sink organs (growing tissues, seasonal storage) are longer. (13)C measurements in respiratory efflux at high temporal resolution provide the best estimate of the mean residence times of C in respiratory substrate pools, and the best basis for compartmental modelling. Seasonal C dynamics and allocation patterns indicate that sink strength variations are important drivers for C fluxes. We propose a conceptual model for temperate and boreal trees, which considers the use of recently assimilated C versus stored C. We recommend best practices for designing and analysing pulse-labelling experiments, and identify several topics which we consider of prime importance for future research on C allocation in trees: (i) whole-tree C source-sink relations, (ii) C allocation to secondary metabolism, (iii) responses to environmental change, (iv) effects of seasonality versus phenology in and across biomes, and (v) carbon-nitrogen interactions. Substantial progress is expected from emerging technologies, but the largest challenge

  10. Label-Free Electrical Immunosensor for Highly Sensitive and Specific Detection of Microcystin-LR in Water Samples.

    PubMed

    Tan, Feng; Saucedo, Nuvia Maria; Ramnani, Pankaj; Mulchandani, Ashok

    2015-08-04

    Microcystin-LR (MCLR) is one of the most commonly detected and toxic cyclic heptapeptide cyanotoxins released by cyanobacterial blooms in surface waters, for which sensitive and specific detection methods are necessary to carry out its recognition and quantification. Here, we present a single-walled carbon nanotube (SWCNTs)-based label-free chemiresistive immunosensor for highly sensitive and specific detection of MCLR in different source waters. MCLR was initially immobilized on SWCNTs modified interdigitated electrode, followed by incubation with monoclonal anti-MCLR antibody. The competitive binding of MCLR in sample solutions induced departure of the antibody from the antibody-antigen complexes formed on SWCNTs, resulting in change in the conductivity between source and drain of the sensor. The displacement assay greatly improved the sensitivity of the sensor compared with direct immunoassay on the same device. The immunosensor exhibited a wide linear response to log value of MCLR concentration ranging from 1 to 1000 ng/L, with a detection limit of 0.6 ng/L. This method showed good reproducibility, stability and recovery. The proposed method provides a powerful tool for rapid and sensitive monitoring of MCLR in environmental samples.

  11. Labeled ALPHA4BETA2 ligands and methods therefor

    DOEpatents

    Mukherjee, Jogeshwar; Pichika, Ramaiah; Potkin, Steven; Leslie, Frances; Chattopadhyay, Sankha

    2013-02-19

    Contemplated compositions and methods are employed to bind in vitro and in vivo to an .alpha.4.beta.2 nicotinic acetylcholine receptor in a highly selective manner. Where such compounds are labeled, compositions and methods employing such compounds can be used for PET and SPECT analysis. Alternatively, and/or additionally contemplated compounds can be used as antagonists, partial agonists or agonists in the treatment of diseases or conditions associated with .alpha.4.beta..beta.2 dysfunction.

  12. Comparing model-based and model-free analysis methods for QUASAR arterial spin labeling perfusion quantification.

    PubMed

    Chappell, Michael A; Woolrich, Mark W; Petersen, Esben T; Golay, Xavier; Payne, Stephen J

    2013-05-01

    Amongst the various implementations of arterial spin labeling MRI methods for quantifying cerebral perfusion, the QUASAR method is unique. By using a combination of labeling with and without flow suppression gradients, the QUASAR method offers the separation of macrovascular and tissue signals. This permits local arterial input functions to be defined and "model-free" analysis, using numerical deconvolution, to be used. However, it remains unclear whether arterial spin labeling data are best treated using model-free or model-based analysis. This work provides a critical comparison of these two approaches for QUASAR arterial spin labeling in the healthy brain. An existing two-component (arterial and tissue) model was extended to the mixed flow suppression scheme of QUASAR to provide an optimal model-based analysis. The model-based analysis was extended to incorporate dispersion of the labeled bolus, generally regarded as the major source of discrepancy between the two analysis approaches. Model-free and model-based analyses were compared for perfusion quantification including absolute measurements, uncertainty estimation, and spatial variation in cerebral blood flow estimates. Major sources of discrepancies between model-free and model-based analysis were attributed to the effects of dispersion and the degree to which the two methods can separate macrovascular and tissue signal. Copyright © 2012 Wiley Periodicals, Inc.

  13. In Silico Labeling: Predicting Fluorescent Labels in Unlabeled Images.

    PubMed

    Christiansen, Eric M; Yang, Samuel J; Ando, D Michael; Javaherian, Ashkan; Skibinski, Gaia; Lipnick, Scott; Mount, Elliot; O'Neil, Alison; Shah, Kevan; Lee, Alicia K; Goyal, Piyush; Fedus, William; Poplin, Ryan; Esteva, Andre; Berndl, Marc; Rubin, Lee L; Nelson, Philip; Finkbeiner, Steven

    2018-04-19

    Microscopy is a central method in life sciences. Many popular methods, such as antibody labeling, are used to add physical fluorescent labels to specific cellular constituents. However, these approaches have significant drawbacks, including inconsistency; limitations in the number of simultaneous labels because of spectral overlap; and necessary perturbations of the experiment, such as fixing the cells, to generate the measurement. Here, we show that a computational machine-learning approach, which we call "in silico labeling" (ISL), reliably predicts some fluorescent labels from transmitted-light images of unlabeled fixed or live biological samples. ISL predicts a range of labels, such as those for nuclei, cell type (e.g., neural), and cell state (e.g., cell death). Because prediction happens in silico, the method is consistent, is not limited by spectral overlap, and does not disturb the experiment. ISL generates biological measurements that would otherwise be problematic or impossible to acquire. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Protoplast Volume:Water Potential Relationship and Bound Water Fraction in Spinach Leaves 1

    PubMed Central

    Santakumari, Mane; Berkowitz, Gerald A.

    1989-01-01

    Methods used to estimate the (nonosmotic) bound water fraction (BWF) (i.e. apoplast water) of spinach (Spinacia oleracea L.) leaves were evaluated. Studies using three different methods of pressure/volume (P/V) curve construction all resulted in a similar calculation of BWF; approximately 40%. The theoretically derived BWF, and the water potential (Ψw)/relative water content relationship established from P/V curves were used to establish the relationship between protoplast (i.e. symplast) volume and Ψw. Another method of establishing the protoplast volume/Ψw relationship in spinach leaves was compared with the results from P/V curve experiments. This second technique involved the vacuum infiltration of solutions at a range of osmotic potentials into discs cut from spinach leaves. These solutions contained radioactively labeled H2O and sorbitol. This dual label infiltration technique allowed for simultaneous measurement of the total and apoplast volumes in leaf tissue; the difference yielded the protoplast volume. The dual label infiltration experiments and the P/V curve constructions both showed that below −1 megapascals, protoplast volume decreases sharply with decreasing water potential; with 50% reduction in protoplast volume occurring at −1.8 megapascals leaf water potential. PMID:16666983

  15. Comparison of Test Procedures and Energy Efficiency Criteria in Selected International Standards and Labeling Programs for Clothes Washers, Water Dispensers, Vending Machines and CFLs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fridley, David; Zheng, Nina; Zhou, Nan

    Since the late 1970s, energy labeling programs and mandatory energy performance standards have been used in many different countries to improve the efficiency levels of major residential and commercial equipment. As more countries and regions launch programs covering a greater range of products that are traded worldwide, greater attention has been given to harmonizing the specific efficiency criteria in these programs and the test methods for measurements. For example, an international compact fluorescent light (CFL) harmonization initiative was launched in 2006 to focus on collaboration between Australia, China, Europe and North America. Given the long history of standards and labelingmore » programs, most major energy-consuming residential appliances and commercial equipment are already covered under minimum energy performance standards (MEPS) and/or energy labels. For these products, such as clothes washers and CFLs, harmonization may still be possible when national MEPS or labeling thresholds are revised. Greater opportunity for harmonization exists in newer energy-consuming products that are not commonly regulated but are under consideration for new standards and labeling programs. This may include commercial products such as water dispensers and vending machines, which are only covered by MEPS or energy labels in a few countries or regions. As China continues to expand its appliance standards and labeling programs and revise existing standards and labels, it is important to learn from recent international experiences with efficiency criteria and test procedures for the same products. Specifically, various types of standards and labeling programs already exist in North America, Europe and throughout Asia for products in China's 2010 standards and labeling programs, namely clothes washers, water dispensers, vending machines and CFLs. This report thus examines similarities and critical differences in energy efficiency values, test procedure specifications and

  16. Water-budget methods

    USGS Publications Warehouse

    Healy, Richard W.; Scanlon, Bridget R.

    2010-01-01

    A water budget is an accounting of water movement into and out of, and storage change within, some control volume. Universal and adaptable are adjectives that reflect key features of water-budget methods for estimating recharge. The universal concept of mass conservation of water implies that water-budget methods are applicable over any space and time scales (Healy et al., 2007). The water budget of a soil column in a laboratory can be studied at scales of millimeters and seconds. A water-budget equation is also an integral component of atmospheric general circulation models used to predict global climates over periods of decades or more. Water-budget equations can be easily customized by adding or removing terms to accurately portray the peculiarities of any hydrologic system. The equations are generally not bound by assumptions on mechanisms by which water moves into, through, and out of the control volume of interest. So water-budget methods can be used to estimate both diffuse and focused recharge, and recharge estimates are unaffected by phenomena such as preferential flow paths within the unsaturated zone.Water-budget methods represent the largest class of techniques for estimating recharge. Most hydrologic models are derived from a water-budget equation and can therefore be classified as water-budget models. It is not feasible to address all water-budget methods in a single chapter. This chapter is limited to discussion of the “residual” water-budget approach, whereby all variables in a water-budget equation, except for recharge, are independently measured or estimated and recharge is set equal to the residual. This chapter is closely linked with Chapter 3, on modeling methods, because the equations presented here form the basis of many models and because models are often used to estimate individual components in water-budget studies. Water budgets for streams and other surface-water bodies are addressed in Chapter 4. The use of soil-water budgets and

  17. Rapid direct methods for enumeration of specific, active bacteria in water and biofilms

    NASA Technical Reports Server (NTRS)

    McFeters, G. A.; Pyle, B. H.; Lisle, J. T.; Broadaway, S. C.

    1999-01-01

    Conventional methods for detecting indicator and pathogenic bacteria in water may underestimate the actual population due to sublethal environmental injury, inability of the target bacteria to take up nutrients and other physiological factors which reduce bacterial culturability. Rapid and direct methods are needed to more accurately detect and enumerate active bacteria. Such a methodological advance would provide greater sensitivity in assessing the microbiological safety of water and food. The principle goal of this presentation is to describe novel approaches we have formulated for the rapid and simultaneous detection of bacteria plus the determination of their physiological activity in water and other environmental samples. The present version of our method involves the concentration of organisms by membrane filtration or immunomagnetic separation and combines an intracellular fluorochrome (CTC) for assessment of respiratory activity plus fluorescent-labelled antibody detection of specific bacteria. This approach has also been successfully used to demonstrate spatial and temporal heterogeneities of physiological activities in biofilms when coupled with cryosectioning. Candidate physiological stains include those capable of determining respiratory activity, membrane potential, membrane integrity, growth rate and cellular enzymatic activities. Results obtained thus far indicate that immunomagnetic separation can provide a high degree of sensitivity in the recovery of seeded target bacteria (Escherichia coli O157:H7) in water and hamburger. The captured and stained target bacteria are then enumerated by either conventional fluorescence microscopy or ChemScan(R), a new instrument that is very sensitive and rapid. The ChemScan(R) laser scanning instrument (Chemunex, Paris, France) provides the detection of individual fluorescently labelled bacterial cells using three emission channels in less than 5 min. A high degree of correlation has been demonstrated between

  18. The validity of a web-based FFQ assessed by doubly labelled water and multiple 24-h recalls.

    PubMed

    Medin, Anine C; Carlsen, Monica H; Hambly, Catherine; Speakman, John R; Strohmaier, Susanne; Andersen, Lene F

    2017-12-01

    The aim of this study was to validate the estimated habitual dietary intake from a newly developed web-based FFQ (WebFFQ), for use in an adult population in Norway. In total, ninety-two individuals were recruited. Total energy expenditure (TEE) measured by doubly labelled water was used as the reference method for energy intake (EI) in a subsample of twenty-nine women, and multiple 24-h recalls (24HR) were used as the reference method for the relative validation of macronutrients and food groups in the entire sample. Absolute differences, ratios, crude and deattenuated correlations, cross-classifications, Bland-Altman plot and plots between misreporting of EI (EI-TEE) and the relative misreporting of food groups (WebFFQ-24HR) were used to assess the validity. Results showed that EI on group level was not significantly different from TEE measured by doubly labelled water (0·7 MJ/d), but ranking abilities were poor (r -0·18). The relative validation showed an overestimation for the majority of the variables using absolute intakes, especially for the food groups 'vegetables' and 'fish and shellfish', but an improved agreement between the test and reference tool was observed for energy adjusted intakes. Deattenuated correlation coefficients were between 0·22 and 0·89, and low levels of grossly misclassified individuals (0-3 %) were observed for the majority of the energy adjusted variables for macronutrients and food groups. In conclusion, energy estimates from the WebFFQ should be used with caution, but the estimated absolute intakes on group level and ranking abilities seem acceptable for macronutrients and most food groups.

  19. Method for producing labeled single-stranded nucleic acid probes

    DOEpatents

    Dunn, John J.; Quesada, Mark A.; Randesi, Matthew

    1999-10-19

    Disclosed is a method for the introduction of unidirectional deletions in a cloned DNA segment. More specifically, the method comprises providing a recombinant DNA construct comprising a DNA segment of interest inserted in a cloning vector, the cloning vector having an f1 endonuclease recognition sequence adjacent to the insertion site of the DNA segment of interest. The recombinant DNA construct is then contacted with the protein pII encoded by gene II of phage f1 thereby generating a single-stranded nick. The nicked DNA is then contacted with E. coli Exonuclease III thereby expanding the single-stranded nick into a single-stranded gap. The single-stranded gapped DNA is then contacted with a single-strand-specific endonuclease thereby producing a linearized DNA molecule containing a double-stranded deletion corresponding in size to the single-stranded gap. The DNA treated in this manner is then incubated with DNA ligase under conditions appropriate for ligation. Also disclosed is a method for producing single-stranded DNA probes. In this embodiment, single-stranded gapped DNA, produced as described above, is contacted with a DNA polymerase in the presence of labeled nucleotides to fill in the gap. This DNA is then linearized by digestion with a restriction enzyme which cuts outside the DNA segment of interest. The product of this digestion is then denatured to produce a labeled single-stranded nucleic acid probe.

  20. Validation of laboratory-scale recycling test method of paper PSA label products

    Treesearch

    Carl Houtman; Karen Scallon; Richard Oldack

    2008-01-01

    Starting with test methods and a specification developed by the U.S. Postal Service (USPS) Environmentally Benign Pressure Sensitive Adhesive Postage Stamp Program, a laboratory-scale test method and a specification were developed and validated for pressure-sensitive adhesive labels, By comparing results from this new test method and pilot-scale tests, which have been...

  1. A method to trace root-respired CO2 using a 13C label

    NASA Astrophysics Data System (ADS)

    Cooperdock, S.; Breecker, D.; Litvak, M. E.

    2014-12-01

    In order to partition total soil respiration into root respiration and decomposition under ambient conditions in desert soils, the following method was developed using 13C-labeled CO2 in a modern juniper savannah in central New Mexico. The labeled CO2 was mixed with ambient air and pumped into a small (2.5 m diameter and 1.4 m tall) juniper tree canopy . 10 L of the 13CO2 was sufficient to generate a stream of air at 20 L/min for 1 hour with a CO2 concentration of 540 ppm and a δ13C value of approximately 35,000‰. Plastic tarpaulins were used as a wind block. The 13CO2 -labeled air was applied to the canopy during peak photosynthesis between 10 and 11 am on June 30 2014 during which canopy air CO2 was elevated by approximately 10 ppm over ambient and had δ13C values ranging from 50 to 1000 ‰. Over the next three days, gas and tissue samples were collected in order to trace the 13C label through the juniper tree. Leaf and root samples collected from the labeled tree and from several control trees were loaded into exetainer vials, flushed with CO2-free air and incubated in the dark for 5 hours in order to measure the carbon isotope composition of respired CO2. Samples of soil pore space gas were collected from wells under the labeled tree and a control tree and were transported to the laboratory in He-flushed exetainer vials. The δ13C values of CO2 in the soil gas samples and in the headspace of incubation vials were measured using an isotope ratio mass spectrometer. The δ13C values of foliar respiration were significantly higher than those of the control (by 3.6‰, p < 0.01) one and two days after labeling and δ13C values of root-respired CO2 were significantly higher (by 0.7‰, p = 0.01) than those of the control three days after labeling. In addition, δ13C values of soil respired CO2, determined from measurements of soil pore space CO2 at 50 cm three days after labeling, were significantly higher (by 0.7‰, p < 0.03)) for the labeled tree than control

  2. Total energy expenditure of 10- to 12-year-old Japanese children measured using the doubly labeled water method.

    PubMed

    Komura, Keisuke; Nakae, Satoshi; Hirakawa, Kazufumi; Ebine, Naoyuki; Suzuki, Kazuhiro; Ozawa, Haruo; Yamada, Yosuke; Kimura, Misaka; Ishii, Kojiro

    2017-01-01

    To establish Japanese children's estimated energy requirements, total energy expenditure (TEE) data measured using the doubly labeled water (DLW) method is needed. This study aimed to 1) obtain basic TEE data from Japanese children measured using DLW (TEE DLW ), 2) compare TEE DLW with TEE estimated by various estimation formulas to calculate their accuracy, and 3) develop a new equation to estimate TEE using body composition and pedometers. TEE was measured using DLW in 56 10- to 12-year-old Japanese children (33 boys, 23 girls). Physical activity level (PAL) was calculated by dividing TEE DLW by estimated resting energy expenditure. To assess their physical activity, participants wore pedometers during the 7-d DLW period. Total body water was calculated from 2 H and 18 O; fat-free mass (FFM) and fat mass (FM) were then determined. In boys and girls of normal weight, TEE DLW was 2067 ± 230 kcal/d and 1830 ± 262 kcal/d, respectively. Average PAL was 1.58 ± 0.17. FFM was strongly related to TEE ( r  = 0.702, p  < 0.01). After adjusting for FFM and FM, step count was significantly associated with TEE ( r  = 0.707, p  < 0.01). The TEE estimation formula used in the Dietary Reference Intakes (DRI) for the United States and Canada estimated TEE DLW with high accuracy (bias: 2.0%) in both sexes. We developed new equations for TEE consisting of FFM and step count, which accounted for 68% and 65% of TEE variance in boys and girls, respectively: boys, 47.1 × FFM (kg) + 0.0568 × step count (steps/d) - 122, and girls, 55.5 × FFM (kg) + 0.0315 × step count (steps/d) - 117. The TEE in 10- to 12-year-old Japanese children measured using DLW was approximately 7% lower for boys and 12% lower for girls compared to the current Japanese DRI. If PAL can be accurately determined, the equation in the DRI for the United States and Canada may be applicable to Japanese children. In addition, TEE could be predicted using FFM and step count.

  3. Water accessibility in a membrane-inserting peptide comparing Overhauser DNP and pulse EPR methods.

    PubMed

    Segawa, Takuya F; Doppelbauer, Maximilian; Garbuio, Luca; Doll, Andrin; Polyhach, Yevhen O; Jeschke, Gunnar

    2016-05-21

    Water accessibility is a key parameter for the understanding of the structure of biomolecules, especially membrane proteins. Several experimental techniques based on the combination of electron paramagnetic resonance (EPR) spectroscopy with site-directed spin labeling are currently available. Among those, we compare relaxation time measurements and electron spin echo envelope modulation (ESEEM) experiments using pulse EPR with Overhauser dynamic nuclear polarization (DNP) at X-band frequency and a magnetic field of 0.33 T. Overhauser DNP transfers the electron spin polarization to nuclear spins via cross-relaxation. The change in the intensity of the (1)H NMR spectrum of H2O at a Larmor frequency of 14 MHz under a continuous-wave microwave irradiation of the nitroxide spin label contains information on the water accessibility of the labeled site. As a model system for a membrane protein, we use the hydrophobic α-helical peptide WALP23 in unilamellar liposomes of DOPC. Water accessibility measurements with all techniques are conducted for eight peptides with different spin label positions and low radical concentrations (10-20 μM). Consistently in all experiments, the water accessibility appears to be very low, even for labels positioned near the end of the helix. The best profile is obtained by Overhauser DNP, which is the only technique that succeeds in discriminating neighboring positions in WALP23. Since the concentration of the spin-labeled peptides varied, we normalized the DNP parameter ϵ, being the relative change of the NMR intensity, by the electron spin concentration, which was determined from a continuous-wave EPR spectrum.

  4. Saturation recovery EPR spin-labeling method for quantification of lipids in biological membrane domains.

    PubMed

    Mainali, Laxman; Camenisch, Theodore G; Hyde, James S; Subczynski, Witold K

    2017-12-01

    The presence of integral membrane proteins induces the formation of distinct domains in the lipid bilayer portion of biological membranes. Qualitative application of both continuous wave (CW) and saturation recovery (SR) electron paramagnetic resonance (EPR) spin-labeling methods allowed discrimination of the bulk, boundary, and trapped lipid domains. A recently developed method, which is based on the CW EPR spectra of phospholipid (PL) and cholesterol (Chol) analog spin labels, allows evaluation of the relative amount of PLs (% of total PLs) in the boundary plus trapped lipid domain and the relative amount of Chol (% of total Chol) in the trapped lipid domain [ M. Raguz, L. Mainali, W. J. O'Brien, and W. K. Subczynski (2015), Exp. Eye Res., 140:179-186 ]. Here, a new method is presented that, based on SR EPR spin-labeling, allows quantitative evaluation of the relative amounts of PLs and Chol in the trapped lipid domain of intact membranes. This new method complements the existing one, allowing acquisition of more detailed information about the distribution of lipids between domains in intact membranes. The methodological transition of the SR EPR spin-labeling approach from qualitative to quantitative is demonstrated. The abilities of this method are illustrated for intact cortical and nuclear fiber cell plasma membranes from porcine eye lenses. Statistical analysis (Student's t -test) of the data allowed determination of the separations of mean values above which differences can be treated as statistically significant ( P ≤ 0.05) and can be attributed to sources other than preparation/technique.

  5. Household adoption of energy and water-efficient appliances: An analysis of attitudes, labelling and complementary green behaviours in selected OECD countries.

    PubMed

    Dieu-Hang, To; Grafton, R Quentin; Martínez-Espiñeira, Roberto; Garcia-Valiñas, Maria

    2017-07-15

    Using a household-based data set of more than 12,000 households from 11 OECD countries, we analyse the factors underlying the decision by households to adopt energy-efficient and water-efficient equipment. We evaluate the roles of both attitudes and labelling schemes on the adoption of energy and water-efficient equipment, and also the interaction and complementarity between energy and water conservation behaviours. Our findings show: one, 'green' social norms and favourable attitudes towards the environment are associated with an increased likelihood of households' adoption of energy and water-efficient appliances; two, households' purchase decisions are positively affected by their awareness, understanding, and trust of labelling schemes; and three, there is evidence of complementarity between energy conservation and water conservation behaviours. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Water treatment method

    DOEpatents

    Martin, Frank S.; Silver, Gary L.

    1991-04-30

    A method for reducing the concentration of any undesirable metals dissolved in contaminated water, such as waste water. The method involves uniformly reacting the contaminated water with an excess amount of solid particulate calcium sulfite to insolubilize the undesirable metal ions, followed by removal thereof and of the unreacted calcium sulfite.

  7. An optimized method for measuring fatty acids and cholesterol in stable isotope-labeled cells

    PubMed Central

    Argus, Joseph P.; Yu, Amy K.; Wang, Eric S.; Williams, Kevin J.; Bensinger, Steven J.

    2017-01-01

    Stable isotope labeling has become an important methodology for determining lipid metabolic parameters of normal and neoplastic cells. Conventional methods for fatty acid and cholesterol analysis have one or more issues that limit their utility for in vitro stable isotope-labeling studies. To address this, we developed a method optimized for measuring both fatty acids and cholesterol from small numbers of stable isotope-labeled cultured cells. We demonstrate quantitative derivatization and extraction of fatty acids from a wide range of lipid classes using this approach. Importantly, cholesterol is also recovered, albeit at a modestly lower yield, affording the opportunity to quantitate both cholesterol and fatty acids from the same sample. Although we find that background contamination can interfere with quantitation of certain fatty acids in low amounts of starting material, our data indicate that this optimized method can be used to accurately measure mass isotopomer distributions for cholesterol and many fatty acids isolated from small numbers of cultured cells. Application of this method will facilitate acquisition of lipid parameters required for quantifying flux and provide a better understanding of how lipid metabolism influences cellular function. PMID:27974366

  8. MEASURING OF PROTEIN SYNTHESIS USING METABOLIC 2H-LABELING, HIGH-RESOLUTION MASS SPECTROMETRY AND AN ALGORITHM

    PubMed Central

    Kasumov, Takhar; Ilchenko, Sergey; Li, Ling; Rachdaoui, Nadia; Sadigov, Rovshan; Willard, Belinda; McCullough, Arthur J.; Previs, Stephen

    2013-01-01

    We recently developed a method for estimating protin dynamics in vivo with 2H2O using MALDI-TOF MS (Rachdaoui N. et al., MCP, 8, 2653-2662, 2009) and we confirmed that 2H-labeling of many hepatic free amino acids rapidly equilibrated with body water. Although this is a reliable method, it required modest sample purification and necessitated the determination of tissue-specific amino acid labeling. Another approach for quantifying protein kinetics is to measure the 2H-enrichments of body water (precursor) and protein-bound amino acid or proteolytic peptide (product) and to estimate how many copies of deuterium are incorporated into a product. In this study we have used nanospray LTQ-FTICR mass spectrometry to simultaneously measure the isotopic enrichment of peptides and protein-bound amino acids. A mathematical algorithm was developed to aid the data processing. The most notable improvement centers on the fact that the precursor:product labeling ratio can be obtained by measuring the labeling of water and a protein(s) (or peptides) of interest, therein minimizing the need to measure the amino acid labeling. As a proof of principle, we demonstrate that this approach can detect the effect of nutritional status on albumin synthesis in rats given 2H2O. PMID:21256107

  9. Water treatment method

    DOEpatents

    Martin, F.S.; Silver, G.L.

    1991-04-30

    A method is described for reducing the concentration of any undesirable metals dissolved in contaminated water, such as waste water. The method involves uniformly reacting the contaminated water with an excess amount of solid particulate calcium sulfite to insolubilize the undesirable metal ions, followed by removal thereof and of the unreacted calcium sulfite.

  10. Water accessibility in a membrane-inserting peptide comparing Overhauser DNP and pulse EPR methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Segawa, Takuya F., E-mail: takuya.segawa@alumni.ethz.ch; Doppelbauer, Maximilian; Garbuio, Luca

    2016-05-21

    Water accessibility is a key parameter for the understanding of the structure of biomolecules, especially membrane proteins. Several experimental techniques based on the combination of electron paramagnetic resonance (EPR) spectroscopy with site-directed spin labeling are currently available. Among those, we compare relaxation time measurements and electron spin echo envelope modulation (ESEEM) experiments using pulse EPR with Overhauser dynamic nuclear polarization (DNP) at X-band frequency and a magnetic field of 0.33 T. Overhauser DNP transfers the electron spin polarization to nuclear spins via cross-relaxation. The change in the intensity of the {sup 1}H NMR spectrum of H{sub 2}O at a Larmormore » frequency of 14 MHz under a continuous-wave microwave irradiation of the nitroxide spin label contains information on the water accessibility of the labeled site. As a model system for a membrane protein, we use the hydrophobic α-helical peptide WALP23 in unilamellar liposomes of DOPC. Water accessibility measurements with all techniques are conducted for eight peptides with different spin label positions and low radical concentrations (10–20 μM). Consistently in all experiments, the water accessibility appears to be very low, even for labels positioned near the end of the helix. The best profile is obtained by Overhauser DNP, which is the only technique that succeeds in discriminating neighboring positions in WALP23. Since the concentration of the spin-labeled peptides varied, we normalized the DNP parameter ϵ, being the relative change of the NMR intensity, by the electron spin concentration, which was determined from a continuous-wave EPR spectrum.« less

  11. Synchrotron X-ray footprinting as a method to visualize water in proteins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gupta, Sayan; Feng, Jun; Chan, Leanne Jade G.

    The vast majority of biomolecular processes are controlled or facilitated by water interactions. In enzymes, regulatory proteins, membrane-bound receptors and ion-channels, water bound to functionally important residues creates hydrogen-bonding networks that underlie the mechanism of action of the macromolecule. High-resolution X-ray structures are often difficult to obtain with many of these classes of proteins because sample conditions, such as the necessity of detergents, often impede crystallization. Other biophysical techniques such as neutron scattering, nuclear magnetic resonance and Fourier transform infrared spectroscopy are useful for studying internal water, though each has its own advantages and drawbacks, and often a hybrid approachmore » is required to address important biological problems associated with protein–water interactions. One major area requiring more investigation is the study of bound water molecules which reside in cavities and channels and which are often involved in both the structural and functional aspects of receptor, transporter and ion channel proteins. Recently, significant progress has been made in synchrotron-based radiolytic labeling and mass spectroscopy techniques for both the identification of bound waters and for characterizing the role of water in protein conformational changes at a high degree of spatial and temporal resolution. Finally, here the latest developments and future capabilities of this method for investigating water–protein interactions and its synergy with other synchrotron-based methods are discussed.« less

  12. Synchrotron X-ray footprinting as a method to visualize water in proteins

    DOE PAGES

    Gupta, Sayan; Feng, Jun; Chan, Leanne Jade G.; ...

    2016-07-27

    The vast majority of biomolecular processes are controlled or facilitated by water interactions. In enzymes, regulatory proteins, membrane-bound receptors and ion-channels, water bound to functionally important residues creates hydrogen-bonding networks that underlie the mechanism of action of the macromolecule. High-resolution X-ray structures are often difficult to obtain with many of these classes of proteins because sample conditions, such as the necessity of detergents, often impede crystallization. Other biophysical techniques such as neutron scattering, nuclear magnetic resonance and Fourier transform infrared spectroscopy are useful for studying internal water, though each has its own advantages and drawbacks, and often a hybrid approachmore » is required to address important biological problems associated with protein–water interactions. One major area requiring more investigation is the study of bound water molecules which reside in cavities and channels and which are often involved in both the structural and functional aspects of receptor, transporter and ion channel proteins. Recently, significant progress has been made in synchrotron-based radiolytic labeling and mass spectroscopy techniques for both the identification of bound waters and for characterizing the role of water in protein conformational changes at a high degree of spatial and temporal resolution. Finally, here the latest developments and future capabilities of this method for investigating water–protein interactions and its synergy with other synchrotron-based methods are discussed.« less

  13. Environmental labeling of car tires--toxicity to Daphnia magna can be used as a screening method.

    PubMed

    Wik, Anna; Dave, Göran

    2005-02-01

    Car tires contain several water-soluble compounds that can leach into water and have toxic effects on aquatic organisms. Due to tire wear, 10,000 tonnes of rubber particles end up along the Swedish roads every year. This leads to a diffuse input of emissions of several compounds. Emissions of polyaromatic hydrocarbons (PAHs) are of particular concern. PAHs are ingredients of the high aromatic oil (HA oil) that is used in the rubber as a softener and as a filler. The exclusion of HA oils from car tires has started, and an environmental labeling of tires could make HA oils obsolete. The toxicity to Daphnia magna from 12 randomly selected car tires was tested in this study. Rubber from the tread of the tires was grated into small pieces, to simulate material from tire wear, and the rubber was equilibrated with dilution water for 72 h before addition of test organisms. The 24-h EC50s of the rubber pieces ranged from 0.29 to 32 gl-1, and the 48-h EC50s ranged from 0.0625 to 2.41 gl-1. Summer tires were more toxic than winter tires. After the 48-h exposure, the daphnids were exposed to UV-light for 2 h, to determine if the tires contained compounds that were phototoxic. After UV-activation the EC50s ranged from 0.0625 to 0.38 gl-1. Four of the 12 tires had a very distinct photoactivation, with a toxicity increase of >10 times. This study has shown that the used method for toxicity testing with Daphnia magna according to ISO 6341 could be used as a basis for environmental labeling of car tires.

  14. Method for rapid base sequencing in DNA and RNA with two base labeling

    DOEpatents

    Jett, James H.; Keller, Richard A.; Martin, John C.; Posner, Richard G.; Marrone, Babetta L.; Hammond, Mark L.; Simpson, Daniel J.

    1995-01-01

    Method for rapid-base sequencing in DNA and RNA with two-base labeling and employing fluorescent detection of single molecules at two wavelengths. Bases modified to accept fluorescent labels are used to replicate a single DNA or RNA strand to be sequenced. The bases are then sequentially cleaved from the replicated strand, excited with a chosen spectrum of electromagnetic radiation, and the fluorescence from individual, tagged bases detected in the order of cleavage from the strand.

  15. Measuring the energy expenditure and water flux in free-ranging alpacas (Lama pacos) in the peruvian andes using the doubly labelled water technique.

    PubMed

    Riek, Alexander; Van Der Sluijs, Leendert; Gerken, Martina

    2007-12-01

    Energy expenditure and water flux were measured in free-ranging alpacas Lama pacos, a South American camelid, on natural pastures of the Peruvian Andes (altitude: 4,400 m above sea level). Water influx rate (WIR) was estimated in 16 males (age 2 years, weight 48.5+/-8.6 kg) labelled with 2H. In addition, the field metabolic rate (FMR) was measured in four of these animals labelled with both an oxygen (18O) and a hydrogen (2H) isotope. The WIR averaged 3.62 L H2O/day and the mean total body water 33.1 kg, equal to 68.2% of body weight (BW). The FMR of the four doubly labelled animals was 14.05 MJ/day. New allometric equations were calculated describing the relationships between WIR or FMR and BW, respectively, including published data on ruminants and the present alpaca results. The regression equation indicates that daily WIR scales to a similar metabolic size (kilograms of BW(0.94)) in alpacas than in wild or domesticated ruminants and camelids originating from arid and semiarid habitats. The resulting regression equation for FMR explained over 99% of the variation and corresponded to the function FMR (kilojoules per day)=1079 (kilograms of BW0.668) (n=5, r2=0.995, P<0.001). The FMR measured in this study, the first reported for a South American camelid species, suggests that free-ranging alpacas have similar energy expenditures on a metabolic weight basis as other wild ruminants living under harsh climatic conditions.

  16. Micro-Droplet Detection Method for Measuring the Concentration of Alkaline Phosphatase-Labeled Nanoparticles in Fluorescence Microscopy

    PubMed Central

    Li, Rufeng; Wang, Yibei; Xu, Hong; Fei, Baowei; Qin, Binjie

    2017-01-01

    This paper developed and evaluated a quantitative image analysis method to measure the concentration of the nanoparticles on which alkaline phosphatase (AP) was immobilized. These AP-labeled nanoparticles are widely used as signal markers for tagging biomolecules at nanometer and sub-nanometer scales. The AP-labeled nanoparticle concentration measurement can then be directly used to quantitatively analyze the biomolecular concentration. Micro-droplets are mono-dispersed micro-reactors that can be used to encapsulate and detect AP-labeled nanoparticles. Micro-droplets include both empty micro-droplets and fluorescent micro-droplets, while fluorescent micro-droplets are generated from the fluorescence reaction between the APs adhering to a single nanoparticle and corresponding fluorogenic substrates within droplets. By detecting micro-droplets and calculating the proportion of fluorescent micro-droplets to the overall micro-droplets, we can calculate the AP-labeled nanoparticle concentration. The proposed micro-droplet detection method includes the following steps: (1) Gaussian filtering to remove the noise of overall fluorescent targets, (2) a contrast-limited, adaptive histogram equalization processing to enhance the contrast of weakly luminescent micro-droplets, (3) an red maximizing inter-class variance thresholding method (OTSU) to segment the enhanced image for getting the binary map of the overall micro-droplets, (4) a circular Hough transform (CHT) method to detect overall micro-droplets and (5) an intensity-mean-based thresholding segmentation method to extract the fluorescent micro-droplets. The experimental results of fluorescent micro-droplet images show that the average accuracy of our micro-droplet detection method is 0.9586; the average true positive rate is 0.9502; and the average false positive rate is 0.0073. The detection method can be successfully applied to measure AP-labeled nanoparticle concentration in fluorescence microscopy. PMID:29160812

  17. Micro-Droplet Detection Method for Measuring the Concentration of Alkaline Phosphatase-Labeled Nanoparticles in Fluorescence Microscopy.

    PubMed

    Li, Rufeng; Wang, Yibei; Xu, Hong; Fei, Baowei; Qin, Binjie

    2017-11-21

    This paper developed and evaluated a quantitative image analysis method to measure the concentration of the nanoparticles on which alkaline phosphatase (AP) was immobilized. These AP-labeled nanoparticles are widely used as signal markers for tagging biomolecules at nanometer and sub-nanometer scales. The AP-labeled nanoparticle concentration measurement can then be directly used to quantitatively analyze the biomolecular concentration. Micro-droplets are mono-dispersed micro-reactors that can be used to encapsulate and detect AP-labeled nanoparticles. Micro-droplets include both empty micro-droplets and fluorescent micro-droplets, while fluorescent micro-droplets are generated from the fluorescence reaction between the APs adhering to a single nanoparticle and corresponding fluorogenic substrates within droplets. By detecting micro-droplets and calculating the proportion of fluorescent micro-droplets to the overall micro-droplets, we can calculate the AP-labeled nanoparticle concentration. The proposed micro-droplet detection method includes the following steps: (1) Gaussian filtering to remove the noise of overall fluorescent targets, (2) a contrast-limited, adaptive histogram equalization processing to enhance the contrast of weakly luminescent micro-droplets, (3) an red maximizing inter-class variance thresholding method (OTSU) to segment the enhanced image for getting the binary map of the overall micro-droplets, (4) a circular Hough transform (CHT) method to detect overall micro-droplets and (5) an intensity-mean-based thresholding segmentation method to extract the fluorescent micro-droplets. The experimental results of fluorescent micro-droplet images show that the average accuracy of our micro-droplet detection method is 0.9586; the average true positive rate is 0.9502; and the average false positive rate is 0.0073. The detection method can be successfully applied to measure AP-labeled nanoparticle concentration in fluorescence microscopy.

  18. Automated anatomical labeling method for abdominal arteries extracted from 3D abdominal CT images

    NASA Astrophysics Data System (ADS)

    Oda, Masahiro; Hoang, Bui Huy; Kitasaka, Takayuki; Misawa, Kazunari; Fujiwara, Michitaka; Mori, Kensaku

    2012-02-01

    This paper presents an automated anatomical labeling method of abdominal arteries. In abdominal surgery, understanding of blood vessel structure concerning with a target organ is very important. Branching pattern of blood vessels differs among individuals. It is required to develop a system that can assist understanding of a blood vessel structure and anatomical names of blood vessels of a patient. Previous anatomical labbeling methods for abdominal arteries deal with either of the upper or lower abdominal arteries. In this paper, we present an automated anatomical labeling method of both of the upper and lower abdominal arteries extracted from CT images. We obtain a tree structure of artery regions and calculate feature values for each branch. These feature values include the diameter, curvature, direction, and running vectors of a branch. Target arteries of this method are grouped based on branching conditions. The following processes are separately applied for each group. We compute candidate artery names by using classifiers that are trained to output artery names. A correction process of the candidate anatomical names based on the rule of majority is applied to determine final names. We applied the proposed method to 23 cases of 3D abdominal CT images. Experimental results showed that the proposed method is able to perform nomenclature of entire major abdominal arteries. The recall and the precision rates of labeling are 79.01% and 80.41%, respectively.

  19. Student experiences with traffic‐light labels at college cafeterias: a mixed methods study

    PubMed Central

    Block, J. P.; Chatterjee, A.

    2018-01-01

    Summary Objective To assess student perceptions of traffic‐light labels (TLLs) in college cafeterias. Design Cross‐sectional, mixed‐methods study. Setting One northeastern US college. Participants A total of 1,294 survey respondents; 57 focus group participants. Interventions Seven‐week traffic‐light labelling (green = ‘nutrient‐rich’, yellow = ‘less nutrient‐rich’, red = ‘more nutrient‐rich choice in green or yellow’) intervention at two college cafeterias. Main Outcome Measure(s) Perceptions of TLLs and food labelling; disordered eating behaviours. Analysis Performed χ2 analyses to test for differences between pre‐intervention and postintervention responses, and between postintervention subgroups stratified by site, gender, weight status and varsity athlete status. Qualitative analysis based on the immersion‐crystallization method. Results In postintervention surveys, 60% found TLLs helpful, and 57% used them a few times a week. When asked whether TLLs increased risk of developing eating disorders, 16% of participants said they did and 47% said TLLs might exacerbate existing eating disorders. In focus groups, some students thought the red ‘colour seemed jarring’, but the vast majority agreed ‘the more nutrition information available, the better’. Conclusions and Implications Students generally supported TLLs, but future college‐based interventions should address eating disorder concerns. Labels that incorporate nutrition information and education, and avoid negative messaging or judgment of what students eat, may be more acceptable. PMID:29670754

  20. Physical activity levels from a meta-analysis of doubly labeled water studies for validating energy intake as measured by dietary assessment.

    PubMed

    Black, A E

    1996-06-01

    Studies using doubly labeled water have identified underreporting of food intake as a problem of dietary surveys. However, reported energy intakes may be evaluated by comparison with energy requirements expressed as multiples of the basal metabolic rate, and a formula for calculating the value below which reported intake cannot be either a valid measure of habitual intake or a true low intake obtained by chance is presented. The energy requirements of different age-sex groups needed for the comparison with energy intakes have been obtained from a meta-analysis of doubly labeled water data.

  1. Hydration measured by doubly labeled water in ALS and its effects on survival.

    PubMed

    Scagnelli, Connor N; Howard, Diantha B; Bromberg, Mark B; Kasarskis, Edward J; Matthews, Dwight E; Mitsumoto, Hiroshi M; Simmons, Zachary; Tandan, Rup

    2018-05-01

    We present a study of hydration in ALS patients and its effects on survival. This was a multicenter study over 48 weeks in 80 ALS patients who underwent 250 individual measurements using doubly labeled water (DLW). Total body water (TBW) and water turnover (a surrogate for water intake) were 3.4% and 8.6% lower, respectively, in patients compared to age- and gender-matched healthy controls, and both significantly decreased over study duration. In 20% of patients, water turnover measured over 10 d was 2 standard deviations below the mean value in healthy controls. In a separate clinic cohort of 208 patients, water intake estimated from a de novo equation created from common clinical endpoints was a prognostic indicator of survival. Regardless of nutritional state assessed by BMI, survival was two-fold longer in the group above the median for estimated water intake, suggesting that hydration may be a more important predictor of survival than malnutrition. Risk factors for poor hydration were identified. Water intake equations recommended by US Centers for Medicare and Medicaid Services in healthy elderly were inaccurate for use in ALS patients. We developed equations to estimate TBW and water intake in ALS patients for use in clinics to accurately estimate hydration and improve clinical care.

  2. Method for rapid base sequencing in DNA and RNA with two base labeling

    DOEpatents

    Jett, J.H.; Keller, R.A.; Martin, J.C.; Posner, R.G.; Marrone, B.L.; Hammond, M.L.; Simpson, D.J.

    1995-04-11

    A method is described for rapid-base sequencing in DNA and RNA with two-base labeling and employing fluorescent detection of single molecules at two wavelengths. Bases modified to accept fluorescent labels are used to replicate a single DNA or RNA strand to be sequenced. The bases are then sequentially cleaved from the replicated strand, excited with a chosen spectrum of electromagnetic radiation, and the fluorescence from individual, tagged bases detected in the order of cleavage from the strand. 4 figures.

  3. Detection of Legionella pneumophila by PCR-ELISA method in industrial cooling tower water.

    PubMed

    Soheili, Majid; Nejadmoghaddam, Mohammad Reza; Babashamsi, Mohammad; Ghasemi, Jamileh; Jeddi Tehrani, Mahmood

    2007-11-15

    Water supply and Cooling Tower Water (CTW) are among the most common sources of Legionella pneumophila (LP) contamination. A nonradio active method is described to detect LP in industrial CTW samples. DNA was purified and amplified by nested -PCR with amplimers specific for the 16s rRNA gene of LP. The 5' end biotinylated oligomer probe was immobilized on sterptavidin B coated microtiter plates. The nested-PCR product was labeled with digoxigenin and then hybridized with 5'-biotinylated probes. The amplification products were detected by using proxidase-labled anti dioxygenin antibody in a colorimetric reaction. The assay detected LP present in 1 L of 5 CTW samples examined. All of the samples were Legionella positive in both culture and PCR-ELISA methods. The PCR-ELISA assay appears to exhibit high specificity and is a more rapid technique in comparison with bacterial culture method. Thus could prove suitable for use in the routine examination of industrial CTW contamination.

  4. Development of a facile and sensitive HPLC-FLD method via fluorescence labeling for triterpenic acid bioavailability investigation.

    PubMed

    You, Jinmao; Wu, Di; Zhao, Mei; Li, Guoliang; Gong, Peiwei; Wu, Yueyue; Guo, Yu; Chen, Guang; Zhao, Xianen; Sun, Zhiwei; Xia, Lian; Wu, Yongning

    2017-06-01

    Triterpenic acids are widely distributed in many fruits and are known for their medicinal benefits. The study of bioavailability has been an important task for a better understanding of the triterpenic acids. Although many methods based on fluorescence labeling for triterpenic acid determination have been established, these reported methods needed anhydrous conditions, which are not suitable for the convenient study of triterpenic acid bioavailability. Inspired by that, a versatile method, which overcomes the difficulty of the reported methods, has been first developed in this study. The novel method using 2-[12-benzo[b]acridin-5- (12H)-yl]-acetohydrazide (BAAH) as the fluorescence labeling reagent coupled with high-performance liquid chromatography with fluorescence detection was first developed for the study of triterpenic acid bioavailability. Furthermore, the labeling conditions have been optimized in order to achieve the best fluorescence labeling yield. Under the optimal conditions, the quantitative linear range of analytes was 2-1000 ng mL -1 , and the correlation coefficients were >0.9998. The detection limits for all triterpenic acid derivatives were achieved within the range of 0.28-0.29 ng mL -1 . The proposed method was successfully applied to the study of triterpenic acid bioavailability with excellent applicability and good reproducibility. Copyright © 2016 John Wiley & Sons, Ltd.

  5. Analysis of Hydrogen Isotopic Exchange: Lava Creek Tuff Ash and Isotopically Labeled Water

    NASA Astrophysics Data System (ADS)

    Ross, A. M.; Seligman, A. N.; Bindeman, I. N.; Nolan, G. S.

    2015-12-01

    Nolan and Bindeman (2013) placed secondarily hydrated ash from the 7.7 ka eruption of Mt. Mazama (δD=-149‰, 2.3wt% H2Ot) in isotopically labeled water (+650 ‰ δD, +56 ‰ δ18O) and observed that the H2Ot and δ18O values remained constant, but the δD values of ash increased with the surrounding water at 20, 40 and 70 °C. We expand on this work by conducting a similar experiment with ash from the 640 ka Lava Creek Tuff (LCT, δD of -128 ‰; 2.1 wt.% H2Ot) eruption of Yellowstone to see if significantly older glass (with a hypothesized gel layer on the surface shielding the interior from alteration) produces the same results. We have experiments running at 70, 24, and 5 °C, and periodically remove ~1.5 mg of glass to measure the δD (‰) and H2Ot (wt.%) of water extracted from the glass on a TC/EA MAT 253 continuous flow system. After 600 hours, the δD of the samples left at 5 and 24 °C remains at -128 ‰, but increased 8‰ for the 70 °C run series. However, there is no measurable change in wt.% of H2Ot, indicating that hydrogen exchange is not dictated by the addition of water. We are measuring and will report further progress of isotope exchange. We also plan to analyze the water in the LCT glass for δ18O (‰) to see if, as is the case for the Mt. Mazama glass, the δ18O (‰) remains constant. We also analyzed Mt. Mazama glass from the Nolan and Bindeman (2013) experiments that have now been sitting in isotopically labeled water at room temperature for ~5 years. The water concentration is still unchanged (2.3 wt.% H2Ot), and the δD of the water in the glass is now -111 ‰, causing an increase of 38 ‰. Our preliminary results show that exchange of hydrogen isotopes of hydrated glass is not limited by the age of the glass, and that the testing of hydrogen isotopes of secondarily hydrated glass, regardless of age, may not be a reliable paleoclimate indicator.

  6. 33 CFR 159.16 - Authorization to label devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Authorization to label devices. 159.16 Section 159.16 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION MARINE SANITATION DEVICES Certification Procedures § 159.16 Authorization to label...

  7. Development of a novel method for quantification of autophagic protein degradation by AHA labeling.

    PubMed

    Zhang, Jianbin; Wang, Jigang; Ng, Shukie; Lin, Qingsong; Shen, Han-Ming

    2014-05-01

    Autophagy is a catabolic process during which cellular components including protein aggregates and organelles are degraded via a lysosome-dependent process to sustain metabolic homeostasis during nutrient or energy deprivation. Measuring the rate of proteolysis of long-lived proteins is a classical assay for measurement of autophagic flux. However, traditional methods, such as a radioisotope labeling assay, are technically tedious and have low sensitivity. Here, we report a novel method for quantification of long-lived protein degradation based on L-azidohomoalanine (AHA) labeling in mouse embryonic fibroblasts (MEFs) and in human cancer cells. AHA is a surrogate for L-methionine, containing a bio-orthogonalazide moiety. When added to cultured cells, AHA is incorporated into proteins during active protein synthesis. After a click reaction between an azide and an alkyne, the azide-containing proteins can be detected with an alkyne-tagged fluorescent dye, coupled with flow cytometry. Induction of autophagy by starvation or mechanistic target of rapamycin (MTOR) inhibitors was able to induce a significant reduction of the fluorescence intensity, consistent with other autophagic markers. Coincidently, inhibition of autophagy by pharmacological agents or by Atg gene deletion abolished the reduction of the fluorescence intensity. Compared with the classical radioisotope pulse-labeling method, we think that our method is sensitive, quantitative, nonradioactive, and easy to perform, and can be applied to both human and animal cell culture systems.

  8. Development of a novel method for quantification of autophagic protein degradation by AHA labeling

    PubMed Central

    Zhang, Jianbin; Wang, Jigang; Ng, Shukie; Lin, Qingsong; Shen, Han-Ming

    2014-01-01

    Autophagy is a catabolic process during which cellular components including protein aggregates and organelles are degraded via a lysosome-dependent process to sustain metabolic homeostasis during nutrient or energy deprivation. Measuring the rate of proteolysis of long-lived proteins is a classical assay for measurement of autophagic flux. However, traditional methods, such as a radioisotope labeling assay, are technically tedious and have low sensitivity. Here, we report a novel method for quantification of long-lived protein degradation based on L-azidohomoalanine (AHA) labeling in mouse embryonic fibroblasts (MEFs) and in human cancer cells. AHA is a surrogate for L-methionine, containing a bio-orthogonalazide moiety. When added to cultured cells, AHA is incorporated into proteins during active protein synthesis. After a click reaction between an azide and an alkyne, the azide-containing proteins can be detected with an alkyne-tagged fluorescent dye, coupled with flow cytometry. Induction of autophagy by starvation or mechanistic target of rapamycin (MTOR) inhibitors was able to induce a significant reduction of the fluorescence intensity, consistent with other autophagic markers. Coincidently, inhibition of autophagy by pharmacological agents or by Atg gene deletion abolished the reduction of the fluorescence intensity. Compared with the classical radioisotope pulse-labeling method, we think that our method is sensitive, quantitative, nonradioactive, and easy to perform, and can be applied to both human and animal cell culture systems. PMID:24675368

  9. A multi-label learning based kernel automatic recommendation method for support vector machine.

    PubMed

    Zhang, Xueying; Song, Qinbao

    2015-01-01

    Choosing an appropriate kernel is very important and critical when classifying a new problem with Support Vector Machine. So far, more attention has been paid on constructing new kernels and choosing suitable parameter values for a specific kernel function, but less on kernel selection. Furthermore, most of current kernel selection methods focus on seeking a best kernel with the highest classification accuracy via cross-validation, they are time consuming and ignore the differences among the number of support vectors and the CPU time of SVM with different kernels. Considering the tradeoff between classification success ratio and CPU time, there may be multiple kernel functions performing equally well on the same classification problem. Aiming to automatically select those appropriate kernel functions for a given data set, we propose a multi-label learning based kernel recommendation method built on the data characteristics. For each data set, the meta-knowledge data base is first created by extracting the feature vector of data characteristics and identifying the corresponding applicable kernel set. Then the kernel recommendation model is constructed on the generated meta-knowledge data base with the multi-label classification method. Finally, the appropriate kernel functions are recommended to a new data set by the recommendation model according to the characteristics of the new data set. Extensive experiments over 132 UCI benchmark data sets, with five different types of data set characteristics, eleven typical kernels (Linear, Polynomial, Radial Basis Function, Sigmoidal function, Laplace, Multiquadric, Rational Quadratic, Spherical, Spline, Wave and Circular), and five multi-label classification methods demonstrate that, compared with the existing kernel selection methods and the most widely used RBF kernel function, SVM with the kernel function recommended by our proposed method achieved the highest classification performance.

  10. A Multi-Label Learning Based Kernel Automatic Recommendation Method for Support Vector Machine

    PubMed Central

    Zhang, Xueying; Song, Qinbao

    2015-01-01

    Choosing an appropriate kernel is very important and critical when classifying a new problem with Support Vector Machine. So far, more attention has been paid on constructing new kernels and choosing suitable parameter values for a specific kernel function, but less on kernel selection. Furthermore, most of current kernel selection methods focus on seeking a best kernel with the highest classification accuracy via cross-validation, they are time consuming and ignore the differences among the number of support vectors and the CPU time of SVM with different kernels. Considering the tradeoff between classification success ratio and CPU time, there may be multiple kernel functions performing equally well on the same classification problem. Aiming to automatically select those appropriate kernel functions for a given data set, we propose a multi-label learning based kernel recommendation method built on the data characteristics. For each data set, the meta-knowledge data base is first created by extracting the feature vector of data characteristics and identifying the corresponding applicable kernel set. Then the kernel recommendation model is constructed on the generated meta-knowledge data base with the multi-label classification method. Finally, the appropriate kernel functions are recommended to a new data set by the recommendation model according to the characteristics of the new data set. Extensive experiments over 132 UCI benchmark data sets, with five different types of data set characteristics, eleven typical kernels (Linear, Polynomial, Radial Basis Function, Sigmoidal function, Laplace, Multiquadric, Rational Quadratic, Spherical, Spline, Wave and Circular), and five multi-label classification methods demonstrate that, compared with the existing kernel selection methods and the most widely used RBF kernel function, SVM with the kernel function recommended by our proposed method achieved the highest classification performance. PMID:25893896

  11. Double-label immunofluorescence method for simultaneous detection of adenovirus and herpes simplex virus from the eye.

    PubMed

    Walpita, P; Darougar, S

    1989-07-01

    The development and application of a double-label immunofluorescence method which has the potential to screen for single or dual infections from any site, in single shell vial cultures, is described. In this study, a total of 1,141 ocular specimens were inoculated in shell vials, centrifuged at 15,000 X g for 1 h, incubated at 37 degrees C for 48 h, and fixed in methanol at room temperature for 15 min. The virus inclusions were detected by staining with a double-label indirect immunofluorescence procedure using mixtures of appropriate first antibodies, followed by fluorescein- and rhodamine-conjugated second antibodies. Each specimen was also inoculated in parallel by the conventional virus isolation method. The sensitivity and specificity of the double-label shell vial procedure were comparable to those with the conventional method, and the former test took only 48 h to complete. The test offers a rapid and simple single-vial procedure which allows for individual or simultaneous detection of multiple pathogens. It results in savings in time and cost over the conventional virus isolation method and other shell vial procedures.

  12. Egg labeling methods for gastric emptying scintigraphy are not equivalent in producing a stable solid meal.

    PubMed

    Knight, Linda C; Kantor, Steven; Doma, Siva; Parkman, Henry P; Maurer, Alan H

    2007-11-01

    A wide range of radiolabeled test meals have been used for gastric emptying scintigraphy. The purpose of this study was to test whether (99m)Tc-sulfur colloid-labeled liquid egg white is as stable as 2 fresh whole eggs labeled with (99m)Tc-sulfur colloid and whether the cooking method is important. Whole eggs and liquid egg white were mixed with (99m)Tc-sulfur colloid and cooked by either microwaving or frying on a griddle. The cooked eggs were tested for breakdown after 2 and 4 h of incubation in gastric fluid or HCl. Labeled liquid egg white, prepared by either method of cooking, exhibited less breakdown in gastric fluid than whole eggs. Whole eggs cooked in the microwave exhibited significantly more breakdown than liquid egg white. (99m)Tc-Sulfur colloid binds better to egg whites compared with whole eggs. These results emphasize the need to evaluate the stability of new radiolabeled test meal preparations, including the method of cooking.

  13. 33 CFR 183.514 - Fuel tanks: Labels.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Fuel tanks: Labels. 183.514...) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Equipment Standards § 183.514 Fuel tanks: Labels. (a) Each fuel tank must have a label that meets the requirements of paragraphs (b) through (d) of...

  14. 33 CFR 183.514 - Fuel tanks: Labels.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Fuel tanks: Labels. 183.514...) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Equipment Standards § 183.514 Fuel tanks: Labels. (a) Each fuel tank must have a label that meets the requirements of paragraphs (b) through (d) of...

  15. 16 CFR 301.27 - Label and method of affixing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... all times during the marketing of a fur product the required label shall have a minimum dimension of one and three-fourths (13/4) inches by two and three-fourths (23/4) inches (4.5 cm × 7 cm). Such label...

  16. Co-Labeling for Multi-View Weakly Labeled Learning.

    PubMed

    Xu, Xinxing; Li, Wen; Xu, Dong; Tsang, Ivor W

    2016-06-01

    It is often expensive and time consuming to collect labeled training samples in many real-world applications. To reduce human effort on annotating training samples, many machine learning techniques (e.g., semi-supervised learning (SSL), multi-instance learning (MIL), etc.) have been studied to exploit weakly labeled training samples. Meanwhile, when the training data is represented with multiple types of features, many multi-view learning methods have shown that classifiers trained on different views can help each other to better utilize the unlabeled training samples for the SSL task. In this paper, we study a new learning problem called multi-view weakly labeled learning, in which we aim to develop a unified approach to learn robust classifiers by effectively utilizing different types of weakly labeled multi-view data from a broad range of tasks including SSL, MIL and relative outlier detection (ROD). We propose an effective approach called co-labeling to solve the multi-view weakly labeled learning problem. Specifically, we model the learning problem on each view as a weakly labeled learning problem, which aims to learn an optimal classifier from a set of pseudo-label vectors generated by using the classifiers trained from other views. Unlike traditional co-training approaches using a single pseudo-label vector for training each classifier, our co-labeling approach explores different strategies to utilize the predictions from different views, biases and iterations for generating the pseudo-label vectors, making our approach more robust for real-world applications. Moreover, to further improve the weakly labeled learning on each view, we also exploit the inherent group structure in the pseudo-label vectors generated from different strategies, which leads to a new multi-layer multiple kernel learning problem. Promising results for text-based image retrieval on the NUS-WIDE dataset as well as news classification and text categorization on several real-world multi

  17. Hierarchical Multi-atlas Label Fusion with Multi-scale Feature Representation and Label-specific Patch Partition

    PubMed Central

    Wu, Guorong; Kim, Minjeong; Sanroma, Gerard; Wang, Qian; Munsell, Brent C.; Shen, Dinggang

    2014-01-01

    Multi-atlas patch-based label fusion methods have been successfully used to improve segmentation accuracy in many important medical image analysis applications. In general, to achieve label fusion a single target image is first registered to several atlas images, after registration a label is assigned to each target point in the target image by determining the similarity between the underlying target image patch (centered at the target point) and the aligned image patch in each atlas image. To achieve the highest level of accuracy during the label fusion process it’s critical the chosen patch similarity measurement accurately captures the tissue/shape appearance of the anatomical structure. One major limitation of existing state-of-the-art label fusion methods is that they often apply a fixed size image patch throughout the entire label fusion procedure. Doing so may severely affect the fidelity of the patch similarity measurement, which in turn may not adequately capture complex tissue appearance patterns expressed by the anatomical structure. To address this limitation, we advance state-of-the-art by adding three new label fusion contributions: First, each image patch now characterized by a multi-scale feature representation that encodes both local and semi-local image information. Doing so will increase the accuracy of the patch-based similarity measurement. Second, to limit the possibility of the patch-based similarity measurement being wrongly guided by the presence of multiple anatomical structures in the same image patch, each atlas image patch is further partitioned into a set of label-specific partial image patches according to the existing labels. Since image information has now been semantically divided into different patterns, these new label-specific atlas patches make the label fusion process more specific and flexible. Lastly, in order to correct target points that are mislabeled during label fusion, a hierarchically approach is used to improve the

  18. A comparison of methods for teaching receptive labeling to children with autism spectrum disorders.

    PubMed

    Grow, Laura L; Carr, James E; Kodak, Tiffany M; Jostad, Candice M; Kisamore, April N

    2011-01-01

    Many early intervention curricular manuals recommend teaching auditory-visual conditional discriminations (i.e., receptive labeling) using the simple-conditional method in which component simple discriminations are taught in isolation and in the presence of a distracter stimulus before the learner is required to respond conditionally. Some have argued that this procedure might be susceptible to faulty stimulus control such as stimulus overselectivity (Green, 2001). Consequently, there has been a call for the use of alternative teaching procedures such as the conditional-only method, which involves conditional discrimination training from the onset of intervention. The purpose of the present study was to compare the simple-conditional and conditional-only methods for teaching receptive labeling to 3 young children diagnosed with autism spectrum disorders. The data indicated that the conditional-only method was a more reliable and efficient teaching procedure. In addition, several error patterns emerged during training using the simple-conditional method. The implications of the results with respect to current teaching practices in early intervention programs are discussed.

  19. A COMPARISON OF METHODS FOR TEACHING RECEPTIVE LABELING TO CHILDREN WITH AUTISM SPECTRUM DISORDERS

    PubMed Central

    Grow, Laura L; Carr, James E; Kodak, Tiffany M; Jostad, Candice M; Kisamore, April N

    2011-01-01

    Many early intervention curricular manuals recommend teaching auditory-visual conditional discriminations (i.e., receptive labeling) using the simple-conditional method in which component simple discriminations are taught in isolation and in the presence of a distracter stimulus before the learner is required to respond conditionally. Some have argued that this procedure might be susceptible to faulty stimulus control such as stimulus overselectivity (Green, 2001). Consequently, there has been a call for the use of alternative teaching procedures such as the conditional-only method, which involves conditional discrimination training from the onset of intervention. The purpose of the present study was to compare the simple-conditional and conditional-only methods for teaching receptive labeling to 3 young children diagnosed with autism spectrum disorders. The data indicated that the conditional-only method was a more reliable and efficient teaching procedure. In addition, several error patterns emerged during training using the simple-conditional method. The implications of the results with respect to current teaching practices in early intervention programs are discussed. PMID:21941380

  20. Effectiveness of hydrogen rich water on antioxidant status of subjects with potential metabolic syndrome-an open label pilot study.

    PubMed

    Nakao, Atsunori; Toyoda, Yoshiya; Sharma, Prachi; Evans, Malkanthi; Guthrie, Najla

    2010-03-01

    Metabolic syndrome is characterized by cardiometabolic risk factors that include obesity, insulin resistance, hypertension and dyslipidemia. Oxidative stress is known to play a major role in the pathogenesis of metabolic syndrome. The objective of this study was to examine the effectiveness of hydrogen rich water (1.5-2 L/day) in an open label, 8-week study on 20 subjects with potential metabolic syndrome. Hydrogen rich water was produced, by placing a metallic magnesium stick into drinking water (hydrogen concentration; 0.55-0.65 mM), by the following chemical reaction; Mg + 2H(2)O --> Mg (OH)(2) + H(2). The consumption of hydrogen rich water for 8 weeks resulted in a 39% increase (p<0.05) in antioxidant enzyme superoxide dismutase (SOD) and a 43% decrease (p<0.05) in thiobarbituric acid reactive substances (TBARS) in urine. Further, subjects demonstrated an 8% increase in high density lipoprotein (HDL)-cholesterol and a 13% decrease in total cholesterol/HDL-cholesterol from baseline to week 4. There was no change in fasting glucose levels during the 8 week study. In conclusion, drinking hydrogen rich water represents a potentially novel therapeutic and preventive strategy for metabolic syndrome. The portable magnesium stick was a safe, easy and effective method of delivering hydrogen rich water for daily consumption by participants in the study.

  1. A new dimethyl labeling-based SID-MRM-MS method and its application to three proteases involved in insulin maturation.

    PubMed

    Cheng, Dongwan; Zheng, Li; Hou, Junjie; Wang, Jifeng; Xue, Peng; Yang, Fuquan; Xu, Tao

    2015-01-01

    The absolute quantification of target proteins in proteomics involves stable isotope dilution coupled with multiple reactions monitoring mass spectrometry (SID-MRM-MS). The successful preparation of stable isotope-labeled internal standard peptides is an important prerequisite for the SID-MRM absolute quantification methods. Dimethyl labeling has been widely used in relative quantitative proteomics and it is fast, simple, reliable, cost-effective, and applicable to any protein sample, making it an ideal candidate method for the preparation of stable isotope-labeled internal standards. MRM mass spectrometry is of high sensitivity, specificity, and throughput characteristics and can quantify multiple proteins simultaneously, including low-abundance proteins in precious samples such as pancreatic islets. In this study, a new method for the absolute quantification of three proteases involved in insulin maturation, namely PC1/3, PC2 and CPE, was developed by coupling a stable isotope dimethyl labeling strategy for internal standard peptide preparation with SID-MRM-MS quantitative technology. This method offers a new and effective approach for deep understanding of the functional status of pancreatic β cells and pathogenesis in diabetes.

  2. Neuronal Tracing with Magnetic Labels: NMR Imaging Methods, Preliminary Results, and New Optimized Coils.

    NASA Astrophysics Data System (ADS)

    Ghosh, Pratik

    1992-01-01

    The investigations focussed on in vivo NMR imaging studies of magnetic particles with and within neural cells. NMR imaging methods, both Fourier transform and projection reconstruction, were implemented and new protocols were developed to perform "Neuronal Tracing with Magnetic Labels" on small animal brains. Having performed the preliminary experiments with neuronal tracing, new optimized coils and experimental set-up were devised. A novel gradient coil technology along with new rf-coils were implemented, and optimized for future use with small animals in them. A new magnetic labelling procedure was developed that allowed labelling of billions of cells with ultra -small magnetite particles in a short time. The relationships among the viability of such cells, the amount of label and the contrast in the images were studied as quantitatively as possible. Intracerebral grafting of magnetite labelled fetal rat brain cells made it possible for the first time to attempt monitoring in vivo the survival, differentiation, and possible migration of both host and grafted cells in the host rat brain. This constituted the early steps toward future experiments that may lead to the monitoring of human brain grafts of fetal brain cells. Preliminary experiments with direct injection of horse radish peroxidase-conjugated magnetite particles into neurons, followed by NMR imaging, revealed a possible non-invasive alternative, allowing serial study of the dynamic transport pattern of tracers in single living animals. New gradient coils were built by using parallel solid-conductor ribbon cables that could be wrapped easily and quickly. Rapid rise times provided by these coils allowed implementation of fast imaging methods. Optimized rf-coil circuit development made it possible to understand better the sample-coil properties and the associated trade -offs in cases of small but conducting samples.

  3. Methodology for National Water Savings Model and Spreadsheet Tool—Outdoor Water Use

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, Alison, A; Chen, Yuting; Dunham, Camilla

    This report describes the method Lawrence Berkeley National Laboratory (LBNL) developed to estimate national impacts of the U.S. Environmental Protection Agency’s (EPA’s) WaterSense labeling program for weather-based irrigation controllers (WBIC). Estimated impacts include the national water savings attributable to the program and the net present value of the lifetime water savings for consumers of irrigation controllers.

  4. Structural analysis of N-glycans by the glycan-labeling method using 3-aminoquinoline-based liquid matrix in negative-ion MALDI-MS.

    PubMed

    Nishikaze, Takashi; Kaneshiro, Kaoru; Kawabata, Shin-ichirou; Tanaka, Koichi

    2012-11-06

    Negative-ion fragmentation of underivatized N-glycans has been proven to be more informative than positive-ion fragmentation. Fluorescent labeling via reductive amination is often employed for glycan analysis, but little is known about the influence of the labeling group on negative-ion fragmentation. We previously demonstrated that the on-target glycan-labeling method using 3-aminoquinoline/α-cyano-4-hydroxycinnamic acid (3AQ/CHCA) liquid matrix enables highly sensitive, rapid, and quantitative N-glycan profiling analysis. The current study investigates the suitability of 3AQ-labeled N-glycans for structural analysis based on negative-ion collision-induced dissociation (CID) spectra. 3AQ-labeled N-glycans exhibited simple and informative CID spectra similar to those of underivatized N-glycans, with product ions due to cross-ring cleavages of the chitobiose core and ions specific to two antennae (D and E ions). The interpretation of diagnostic fragment ions suggested for underivatized N-glycans could be directly applied to the 3AQ-labeled N-glycans. However, fluorescently labeled N-glycans by conventional reductive amination, such as 2-aminobenzamide (2AB)- and 2-pyrydilamine (2PA)-labeled N-glycans, exhibited complicated CID spectra consisting of numerous signals formed by dehydration and multiple cleavages. The complicated spectra of 2AB- and 2PA-labeled N-glycans was found to be due to their open reducing-terminal N-acetylglucosamine (GlcNAc) ring, rather than structural differences in the labeling group in the N-glycan derivative. Finally, as an example, the on-target 3AQ labeling method followed by negative-ion CID was applied to structurally analyze neutral N-glycans released from human epidermal growth factor receptor type 2 (HER2) protein. The glycan-labeling method using 3AQ-based liquid matrix should facilitate highly sensitive quantitative and qualitative analyses of glycans.

  5. .sup.123m Te-Labeled biochemicals and method of preparation

    DOEpatents

    Knapp, Jr., Furn F.

    1980-01-01

    A novel class of .sup.123m Te-labeled steroids and amino acids is provided by the method of reacting a .sup.123m Te symmetric diorgano ditelluride with a hydride reducing agent and a source of alkali metal ions to form an alkali metal organo telluride. The alkali metal organo telluride is reacted with a primary halogenated steroidal side chain, amino acid, or amino acid precursor such as hydantoin. The novel compounds are useful as biological tracers and as organal imaging agents.

  6. An accurate proteomic quantification method: fluorescence labeling absolute quantification (FLAQ) using multidimensional liquid chromatography and tandem mass spectrometry.

    PubMed

    Liu, Junyan; Liu, Yang; Gao, Mingxia; Zhang, Xiangmin

    2012-08-01

    A facile proteomic quantification method, fluorescent labeling absolute quantification (FLAQ), was developed. Instead of using MS for quantification, the FLAQ method is a chromatography-based quantification in combination with MS for identification. Multidimensional liquid chromatography (MDLC) with laser-induced fluorescence (LIF) detection with high accuracy and tandem MS system were employed for FLAQ. Several requirements should be met for fluorescent labeling in MS identification: Labeling completeness, minimum side-reactions, simple MS spectra, and no extra tandem MS fragmentations for structure elucidations. A fluorescence dye, 5-iodoacetamidofluorescein, was finally chosen to label proteins on all cysteine residues. The fluorescent dye was compatible with the process of the trypsin digestion and MALDI MS identification. Quantitative labeling was achieved with optimization of reacting conditions. A synthesized peptide and model proteins, BSA (35 cysteines), OVA (five cysteines), were used for verifying the completeness of labeling. Proteins were separated through MDLC and quantified based on fluorescent intensities, followed by MS identification. High accuracy (RSD% < 1.58) and wide linearity of quantification (1-10(5) ) were achieved by LIF detection. The limit of quantitation for the model protein was as low as 0.34 amol. Parts of proteins in human liver proteome were quantified and demonstrated using FLAQ. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Pulse labelling for carbon turnover measurements with a CRDS for wetlands - challenges and solutions

    NASA Astrophysics Data System (ADS)

    Strozecki, Marcin; Samson, Mateusz; Chojnicki, Bogdan H.; Leśny, Jacek; Moni, Christophe; Urbaniak, Marek; Olejnik, Janusz; Juszczak, Radosław; Silvennoinnen, Hanna

    2016-04-01

    Carbon turnover in peatlands has commonly been studied by estimating carbon allocation and decomposition rates by litterbags, assessing changes in carbon stocks and by measuring the biosphere-atmosphere exchange of carbon gases with various chamber methods or by eddy covariance. In addition, C turnover rates have been measured with pulse labelling methods using 13C and 14C (e.g. Bahn et al. 2009). Pulse labeling (PL) studies in wetlands are, however, sparse (e.g. Gao et al. 2015), presumably as descriptive high water table levels and relatively low productivity render successful tracing difficult. Quite low cost fast-gas-analyzers (Cavity Ring Down Spectrometry, CRDS) make PL experiments more cost-worthy, but their applicability at wetland field and further for measuring elevated 13C - levels is challenging. We carried out a PL as a pre-experiment for a larger labelling campaign of the Wetman-project at Rzecin wetland in Poland. We aimed at defining 1) The optimum labeling for the peatland site, 2) The importance of dissolved 13CO2 both for the loss of the pulse label and for the potential bias to respiratory flux, 3) The reliability of the 13CO2 and 13CH4 measurements when using dynamic closed chambers with a factory calibrated CRDS. We labelled the study area by a transparent chamber combined to Picarro CRDS G2201-i (C input during labelling 4.9 μg 13C). After labelling, we monitored the respiratory 13CO2 flux and the 13CO2 content in the peat water over a 10d- period. In addition, we measured the vegetation13C before labelling and 10 days after. Plants assimilated 2.1 μg C of the added 13C. Half of the recovered 13CO2 (3.6 μg C) originated from respiration. Nearly one third of added 13CO2 immediately dissolved in the water, which at the end of the experiment retained 0.5 μg 13C. Finally, 127 % of the added label was recovered. The high recovery was mainly caused by overestimation in the δ13C. The results of our pre-experiment indicate that 1) Measuring

  8. Combustion method for assay of biological materials labeled with carbon-14 or tritium, or double-labeled

    NASA Technical Reports Server (NTRS)

    Huebner, L. G.; Kisieleski, W. E.

    1969-01-01

    Dry catalytic combustion at high temperatures is used for assaying biological materials labeled carbon-14 and tritium, or double-labeled. A modified oxygen-flask technique is combined with standard vacuum-line techniques and includes convenience of direct in-vial collection of final combustion products, giving quantitative recovery of tritium and carbon-14.

  9. 33 CFR 181.17 - Label numbers and letters.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Label numbers and letters. 181.17...) BOATING SAFETY MANUFACTURER REQUIREMENTS Manufacturer Certification of Compliance § 181.17 Label numbers and letters. Letters and numbers on each label must: (a) Be no less than one-eighth of an inch in...

  10. 33 CFR 181.17 - Label numbers and letters.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Label numbers and letters. 181.17...) BOATING SAFETY MANUFACTURER REQUIREMENTS Manufacturer Certification of Compliance § 181.17 Label numbers and letters. Letters and numbers on each label must: (a) Be no less than one-eighth of an inch in...

  11. Transport of North Pacific 137Cs labeled waters to the south-eastern Atlantic Ocean

    NASA Astrophysics Data System (ADS)

    Sanchez-Cabeza, J. A.; Levy, I.; Gastaud, J.; Eriksson, M.; Osvath, I.; Aoyama, M.; Povinec, P. P.; Komura, K.

    2011-04-01

    During the reoccupation of the WOCE transect A10 at 30°S by the BEAGLE2003 cruise, the SHOTS project partners collected a large number of samples for the analysis of isotopic tracers. 137Cs was mostly deposited on the oceans surface during the late 1950s and early 1960s, after the atmospheric detonation of large nuclear devices, which mostly occurred in the Northern Hemisphere. The development of advanced radioanalytical and counting techniques allowed to obtain, for the first time in this region, a zonal section of 137Cs water concentrations, where little information existed before, thus constituting an important benchmark for further studies. 137Cs concentrations in the upper waters (0-1000 m) of the south-eastern Atlantic Ocean are similar to those observed in the south-western Indian Ocean, suggesting transport of 137Cs labeled waters by the Agulhas current to the Benguela Current region. In contrast, bomb radiocarbon data do not show this feature, indicating the usefulness of 137Cs as a radiotracer of water mass transport from the Indian to the South Atlantic Ocean.

  12. Development of a quantitative high-performance thin-layer chromatographic method for sucralose in sewage effluent, surface water, and drinking water.

    PubMed

    Morlock, Gertrud E; Schuele, Leonard; Grashorn, Sebastian

    2011-05-13

    Sucralose, a persistent chlorinated substance used as sweetener, can already be found in waste water, and various countries focused on the release of sucralose into the aquatic environment. A quantitative high-performance thin-layer chromatography (HPTLC) method, which is orthogonal to existing methods, was developed to analyze sucralose in water. After sample preparation, separation of up to 17 samples was performed in parallel on a HPTLC plate silica gel 60 F(254) with a mixture of isopropyl acetate, methanol and water (15:3:1, v/v/v) within 15 min. Due to the weak native UV absorption of sucralose (≤200 nm), various post-chromatographic derivatization reactions were compared to selectively detect sucralose in effluent and surface water matrices. Thereby p-aminobenzoic acid reagent was discovered as a new derivatization reagent for sucralose. Compared to the latter and to β-naphthol, derivatization with aniline diphenylamine o-phosphoric acid reagent was slightly preferred and densitometry was performed by absorbance measurement at 400 nm. The limit of quantification (LOQ) of sucralose in drinking and surface water was calculated to be 100 ng/L for a given recovery rate of 80% and the extraction of a 0.5 L water sample. The sucralose content determined in four water samples obtained during an interlaboratory trial in 2008 was in good agreement to the mean laboratory values of that trial. According to the t-test, which compares the results with the target value, the means obtained by HPTLC were not significantly different from the respective means of six laboratories, analyzed by HPLC-MS/MS or HPLC-TOF-MS with the use of mostly isotopically labeled standards. The good accuracy and high sample throughput capacity proved HPTLC as a well suited method regarding quantification of sucralose in various aqueous matrices. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. Indirect MRI of 17 o-labeled water using steady-state sequences: Signal simulation and preclinical experiment.

    PubMed

    Kudo, Kohsuke; Harada, Taisuke; Kameda, Hiroyuki; Uwano, Ikuko; Yamashita, Fumio; Higuchi, Satomi; Yoshioka, Kunihiro; Sasaki, Makoto

    2018-05-01

    Few studies have been reported for T 2 -weighted indirect 17 O imaging. To evaluate the feasibility of steady-state sequences for indirect 17 O brain imaging. Signal simulation, phantom measurements, and prospective animal experiments were performed in accordance with the institutional guidelines for animal experiments. Signal simulations of balanced steady-state free precession (bSSFP) were performed for concentrations of 17 O ranging from 0.037-1.600%. Phantom measurements with concentrations of 17 O water ranging from 0.037-1.566% were also conducted. Six healthy beagle dogs were scanned with intravenous administration of 20% 17 O-labeled water (1 mL/kg). Dynamic 3D-bSSFP scans were performed at 3T MRI. 17 O-labeled water was injected 60 seconds after the scan start, and the total scan duration was 5 minutes. Based on the result of signal simulation and phantom measurement, signal changes in the beagle dogs were measured and converted into 17 O concentrations. The 17 O concentrations were averaged for every 15 seconds, and compared to the baseline (30-45 sec) with Dunnett's multiple comparison tests. Signal simulation revealed that the relationships between 17 O concentration and the natural logarithm of relative signals were linear. The intraclass correlation coefficient between relative signals in phantom measurement and signal simulations was 0.974. In the animal experiments, significant increases in 17 O concentration (P < 0.05) were observed 60 seconds after the injection of 17 O. At the end of scanning, mean respective 17 O concentrations of 0.084 ± 0.026%, 0.117 ± 0.038, 0.082 ± 0.037%, and 0.049 ± 0.004% were noted for the cerebral cortex, cerebellar cortex, cerebral white matter, and ventricle. Dynamic steady-state sequences were feasible for indirect 17 O imaging, and absolute quantification was possible. This method can be applied for the measurement of permeability and blood flow in the brain, and for kinetic analysis of

  14. A Method for Label-Free, Differential Top-Down Proteomics.

    PubMed

    Ntai, Ioanna; Toby, Timothy K; LeDuc, Richard D; Kelleher, Neil L

    2016-01-01

    Biomarker discovery in the translational research has heavily relied on labeled and label-free quantitative bottom-up proteomics. Here, we describe a new approach to biomarker studies that utilizes high-throughput top-down proteomics and is the first to offer whole protein characterization and relative quantitation within the same experiment. Using yeast as a model, we report procedures for a label-free approach to quantify the relative abundance of intact proteins ranging from 0 to 30 kDa in two different states. In this chapter, we describe the integrated methodology for the large-scale profiling and quantitation of the intact proteome by liquid chromatography-mass spectrometry (LC-MS) without the need for metabolic or chemical labeling. This recent advance for quantitative top-down proteomics is best implemented with a robust and highly controlled sample preparation workflow before data acquisition on a high-resolution mass spectrometer, and the application of a hierarchical linear statistical model to account for the multiple levels of variance contained in quantitative proteomic comparisons of samples for basic and clinical research.

  15. Quantitative study on the fate of residual soil nitrate in winter wheat based on a 15N-labeling method.

    PubMed

    Zhang, Jing-Ting; Wang, Zhi-Min; Liang, Shuang-Bo; Zhang, Ying-Hua; Zhou, Shun-Li; Lu, Lai-Qing; Wang, Run-Zheng

    2017-01-01

    A considerable amount of surplus nitrogen (N), which primarily takes the form of nitrate, accumulates in the soil profile after harvesting crops from an intensive production system in the North China Plain. The residual soil nitrate (RSN) is a key factor that is included in the N recommendation algorithm. Quantifying the utilization and losses of RSN is a fundamental necessity for optimizing crop N management, improving N use efficiency, and reducing the impact derived from farmland N losses on the environment. In this study, a 15N-labeling method was introduced to study the fate of the RSN quantitatively during the winter wheat growing season by 15N tracer technique combined with a soil column study. A soil column with a 2 m height was vertically divided into 10 20-cm layers, and the RSN in each layer was individually labeled with a 15N tracer before the wheat was sown. The results indicated that approximately 17.68% of the crop N derived from RSN was located in the 0-2 m soil profile prior to wheat sowing. The wheat recovery proportions of RSN at various layers ranged from 0.21% to 33.46%. The percentages that still remained in the soil profile after the wheat harvest ranged from 47.08% to 75.44%, and 19.46-32.64% of the RSN was unaccounted for. Upward and downward movements in the RSN were observed, and the maximum upward and downward distances were 40 cm and 100 cm, respectively. In general, the 15N-labeling method contributes to a deeper understanding of the fates of the RSN. Considering the low crop recovery of the RSN from deep soil layers, water and N saving practices should be adopted during crop production.

  16. Automatic prevention of label overlap

    DOT National Transportation Integrated Search

    1976-03-01

    The project comprised a number of simulation exercises : designed to evaluate methods of either preventing or : resolving the problems likely to be caused by label overlap on : Labelled Plan Displays (LPD). The automatic prevention of : label overlap...

  17. 16 CFR 305.16 - Labeling and marking for plumbing products.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... CONGRESS ENERGY AND WATER USE LABELING FOR CONSUMER PRODUCTS UNDER THE ENERGY POLICY AND CONSERVATION ACT... estimated annual operating costs of covered showerheads, faucets, water closets, and urinals or ranges of...) Showerheads and faucets. Showerheads and faucets shall be marked and labeled as follows: (1) Each showerhead...

  18. Apparatus and method for reading two-dimensional electrophoretograms containing .beta.-ray-emitting labeled compounds

    DOEpatents

    Anderson, Herbert L.; Kinnison, W. Wayne; Lillberg, John W.

    1987-01-01

    Apparatus and method for electronically reading planar two dimensional .beta.-ray emitter-labeled gel electrophoretograms. A single, flat rectangular multiwire proportional chamber is placed in close proximity to the gel and the assembly placed in an intense uniform magnetic field disposed in a perpendicular manner to the rectangular face of the proportional chamber. Beta rays emitted in the direction of the proportional chamber are caused to execute helical motions which substantially preserve knowledge of the coordinates of their origin in the gel. Perpendicularly oriented, parallel wire, parallel plane cathodes electronically sense the location of the .beta.-rays from ionization generated thereby in a detection gas coupled with an electron avalanche effect resulting from the action of a parallel wire anode located therebetween. A scintillator permits the present apparatus to be rendered insensitive when signals are generated from cosmic rays incident on the proportional chamber. Resolution for concentrations of radioactive compounds in the gel exceeds 700 .mu.m. The apparatus and method of the present invention represent a significant improvement over conventional autoradiographic techniques in dynamic range, linearity and sensitivity of data collection. A concentration and position map for gel electrophoretograms having significant concentrations of labeled compounds and/or highly radioactive labeling nuclides can generally be obtained in less than one hour.

  19. Learning classification models with soft-label information.

    PubMed

    Nguyen, Quang; Valizadegan, Hamed; Hauskrecht, Milos

    2014-01-01

    Learning of classification models in medicine often relies on data labeled by a human expert. Since labeling of clinical data may be time-consuming, finding ways of alleviating the labeling costs is critical for our ability to automatically learn such models. In this paper we propose a new machine learning approach that is able to learn improved binary classification models more efficiently by refining the binary class information in the training phase with soft labels that reflect how strongly the human expert feels about the original class labels. Two types of methods that can learn improved binary classification models from soft labels are proposed. The first relies on probabilistic/numeric labels, the other on ordinal categorical labels. We study and demonstrate the benefits of these methods for learning an alerting model for heparin induced thrombocytopenia. The experiments are conducted on the data of 377 patient instances labeled by three different human experts. The methods are compared using the area under the receiver operating characteristic curve (AUC) score. Our AUC results show that the new approach is capable of learning classification models more efficiently compared to traditional learning methods. The improvement in AUC is most remarkable when the number of examples we learn from is small. A new classification learning framework that lets us learn from auxiliary soft-label information provided by a human expert is a promising new direction for learning classification models from expert labels, reducing the time and cost needed to label data.

  20. Evaluation of a High Intensity Focused Ultrasound-Immobilized Trypsin Digestion and 18O-Labeling Method for Quantitative Proteomics

    PubMed Central

    López-Ferrer, Daniel; Hixson, Kim K.; Smallwood, Heather; Squier, Thomas C.; Petritis, Konstantinos; Smith, Richard D.

    2009-01-01

    A new method that uses immobilized trypsin concomitant with ultrasonic irradiation results in ultra-rapid digestion and thorough 18O labeling for quantitative protein comparisons. The reproducible and highly efficient method provided effective digestions in <1 min with a minimized amount of enzyme required compared to traditional methods. This method was demonstrated for digestion of both simple and complex protein mixtures, including bovine serum albumin, a global proteome extract from the bacteria Shewanella oneidensis, and mouse plasma, as well as 18O labeling of such complex protein mixtures, which validated the application of this method for differential proteomic measurements. This approach is simple, reproducible, cost effective, rapid, and thus well-suited for automation. PMID:19555078

  1. Progressive multi-atlas label fusion by dictionary evolution.

    PubMed

    Song, Yantao; Wu, Guorong; Bahrami, Khosro; Sun, Quansen; Shen, Dinggang

    2017-02-01

    Accurate segmentation of anatomical structures in medical images is important in recent imaging based studies. In the past years, multi-atlas patch-based label fusion methods have achieved a great success in medical image segmentation. In these methods, the appearance of each input image patch is first represented by an atlas patch dictionary (in the image domain), and then the latent label of the input image patch is predicted by applying the estimated representation coefficients to the corresponding anatomical labels of the atlas patches in the atlas label dictionary (in the label domain). However, due to the generally large gap between the patch appearance in the image domain and the patch structure in the label domain, the estimated (patch) representation coefficients from the image domain may not be optimal for the final label fusion, thus reducing the labeling accuracy. To address this issue, we propose a novel label fusion framework to seek for the suitable label fusion weights by progressively constructing a dynamic dictionary in a layer-by-layer manner, where the intermediate dictionaries act as a sequence of guidance to steer the transition of (patch) representation coefficients from the image domain to the label domain. Our proposed multi-layer label fusion framework is flexible enough to be applied to the existing labeling methods for improving their label fusion performance, i.e., by extending their single-layer static dictionary to the multi-layer dynamic dictionary. The experimental results show that our proposed progressive label fusion method achieves more accurate hippocampal segmentation results for the ADNI dataset, compared to the counterpart methods using only the single-layer static dictionary. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Validation of Web-Based Physical Activity Measurement Systems Using Doubly Labeled Water

    PubMed Central

    Yamaguchi, Yukio; Yamada, Yosuke; Tokushima, Satoru; Hatamoto, Yoichi; Sagayama, Hiroyuki; Kimura, Misaka; Higaki, Yasuki; Tanaka, Hiroaki

    2012-01-01

    Background Online or Web-based measurement systems have been proposed as convenient methods for collecting physical activity data. We developed two Web-based physical activity systems—the 24-hour Physical Activity Record Web (24hPAR WEB) and 7 days Recall Web (7daysRecall WEB). Objective To examine the validity of two Web-based physical activity measurement systems using the doubly labeled water (DLW) method. Methods We assessed the validity of the 24hPAR WEB and 7daysRecall WEB in 20 individuals, aged 25 to 61 years. The order of email distribution and subsequent completion of the two Web-based measurements systems was randomized. Each measurement tool was used for a week. The participants’ activity energy expenditure (AEE) and total energy expenditure (TEE) were assessed over each week using the DLW method and compared with the respective energy expenditures estimated using the Web-based systems. Results The mean AEE was 3.90 (SD 1.43) MJ estimated using the 24hPAR WEB and 3.67 (SD 1.48) MJ measured by the DLW method. The Pearson correlation for AEE between the two methods was r = .679 (P < .001). The Bland-Altman 95% limits of agreement ranged from –2.10 to 2.57 MJ between the two methods. The Pearson correlation for TEE between the two methods was r = .874 (P < .001). The mean AEE was 4.29 (SD 1.94) MJ using the 7daysRecall WEB and 3.80 (SD 1.36) MJ by the DLW method. The Pearson correlation for AEE between the two methods was r = .144 (P = .54). The Bland-Altman 95% limits of agreement ranged from –3.83 to 4.81 MJ between the two methods. The Pearson correlation for TEE between the two methods was r = .590 (P = .006). The average input times using terminal devices were 8 minutes and 10 seconds for the 24hPAR WEB and 6 minutes and 38 seconds for the 7daysRecall WEB. Conclusions Both Web-based systems were found to be effective methods for collecting physical activity data and are appropriate for use in epidemiological studies. Because the measurement

  3. Total energy expenditure in burned children using the doubly labeled water technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goran, M.I.; Peters, E.J.; Herndon, D.N.

    Total energy expenditure (TEE) was measured in 15 burned children with the doubly labeled water technique. Application of the technique in burned children required evaluation of potential errors resulting from nutritional intake altering background enrichments during studies and from the high rate of water turnover relative to CO2 production. Five studies were discarded because of these potential problems. TEE was 1.33 +/- 0.27 times predicted basal energy expenditure (BEE), and in studies where resting energy expenditure (REE) was simultaneously measured, TEE was 1.18 +/- 0.17 times REE, which in turn was 1.16 +/- 0.10 times predicted BEE. TEE was significantlymore » correlated with measured REE (r2 = 0.92) but not with predicted BEE. These studies substantiate the advantage of measuring REE to predict TEE in severely burned patients as opposed to relying on standardized equations. Therefore we recommend that optimal nutritional support will be achieved in convalescent burned children by multiplying REE by an activity factor of 1.2.« less

  4. Application of Nemerow Index Method and Integrated Water Quality Index Method in Water Quality Assessment of Zhangze Reservoir

    NASA Astrophysics Data System (ADS)

    Zhang, Qian; Feng, Minquan; Hao, Xiaoyan

    2018-03-01

    [Objective] Based on the water quality historical data from the Zhangze Reservoir from the last five years, the water quality was assessed by the integrated water quality identification index method and the Nemerow pollution index method. The results of different evaluation methods were analyzed and compared and the characteristics of each method were identified.[Methods] The suitability of the water quality assessment methods were compared and analyzed, based on these results.[Results] the water quality tended to decrease over time with 2016 being the year with the worst water quality. The sections with the worst water quality were the southern and northern sections.[Conclusion] The results produced by the traditional Nemerow index method fluctuated greatly in each section of water quality monitoring and therefore could not effectively reveal the trend of water quality at each section. The combination of qualitative and quantitative measures of the comprehensive pollution index identification method meant it could evaluate the degree of water pollution as well as determine that the river water was black and odorous. However, the evaluation results showed that the water pollution was relatively low.The results from the improved Nemerow index evaluation were better as the single indicators and evaluation results are in strong agreement; therefore the method is able to objectively reflect the water quality of each water quality monitoring section and is more suitable for the water quality evaluation of the reservoir.

  5. End labeling procedures: an overview.

    PubMed

    Hilario, Elena

    2004-09-01

    There are two ways to label a DNA molecular; by the ends or all along the molecule. End labeling can be performed at the 3'- or 5'-end. Labeling at the 3' end is performed by filling 3'-end recessed ends with a mixture or labeled and unlabeled dNTPs using Klenow or T4 DNA polymerases. Both reactions are template dependent. Terminal deoxynucleotide transferase incorporates dNTPs at the 3' end of any kind of DNA molecule or RNA. Labels incorporated at the 3'-end of the DNA molecule prevent any further extension or ligation to any other molecule, but this can be overcome by labeling the 5'-end of the desired DNA molecule. 5'-end labeling is performed by enzymatic methods (T4 polynucleotide kinase exchange and forward reactions), by chemical modification of sensitized oligonucleotides with phosphoroamidite, or by combined methods. Probe cleanup is recommended when high background problems occur, but caution should be taken not to damage the attached probe with harsh chemicals or by light exposure.

  6. Testing isotopic labeling with [¹³C₆]glucose as a method of advanced glycation sites identification.

    PubMed

    Kielmas, Martyna; Kijewska, Monika; Stefanowicz, Piotr; Szewczuk, Zbigniew

    2012-12-01

    The Maillard reaction occurring between reducing sugars and reactive amino groups of biomolecules leads to the formation of a heterogeneous mixture of compounds: early, intermediate, and advanced glycation end products (AGEs). These compounds could be markers of certain diseases and of the premature aging process. Detection of Amadori products can be performed by various methods, including MS/MS techniques and affinity chromatography on immobilized boronic acid. However, the diversity of the structures of AGEs makes detection of these compounds more difficult. The aim of this study was to test a new method of AGE identification based on isotope (13)C labeling. The model protein (hen egg lysozyme) was modified with an equimolar mixture of [(12)C(6)]glucose and [(13)C(6)]glucose and then subjected to reduction of the disulfide bridges followed by tryptic hydrolysis. The digest obtained was analyzed by LC-MS. The glycation products were identified on the basis of characteristic isotopic patterns resulting from the use of isotopically labeled glucose. This method allowed identification of 38 early Maillard reaction products and five different structures of the end glycation products. This isotopic labeling technique combined with LC-MS is a sensitive method for identification of advanced glycation end products even if their chemical structure is unknown. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. 21 CFR 355.60 - Professional labeling.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... water supply contains 0.3 to 0.7 ppm fluoride ion, reduce the dose to 2.5 mL of 0.02 percent or 5 mL of... labeling. (a) The labeling for anticaries fluoride treatment rinses identified in § 355.10(a)(3) and (c)(3) that are specially formulated so they may be swallowed (fluoride supplements) and are provided to...

  8. 21 CFR 355.60 - Professional labeling.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... water supply contains 0.3 to 0.7 ppm fluoride ion, reduce the dose to 2.5 mL of 0.02 percent or 5 mL of... labeling. (a) The labeling for anticaries fluoride treatment rinses identified in § 355.10(a)(3) and (c)(3) that are specially formulated so they may be swallowed (fluoride supplements) and are provided to...

  9. 21 CFR 355.60 - Professional labeling.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... water supply contains 0.3 to 0.7 ppm fluoride ion, reduce the dose to 2.5 mL of 0.02 percent or 5 mL of... labeling. (a) The labeling for anticaries fluoride treatment rinses identified in § 355.10(a)(3) and (c)(3) that are specially formulated so they may be swallowed (fluoride supplements) and are provided to...

  10. 21 CFR 355.60 - Professional labeling.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... water supply contains 0.3 to 0.7 ppm fluoride ion, reduce the dose to 2.5 mL of 0.02 percent or 5 mL of... labeling. (a) The labeling for anticaries fluoride treatment rinses identified in § 355.10(a)(3) and (c)(3) that are specially formulated so they may be swallowed (fluoride supplements) and are provided to...

  11. 21 CFR 355.60 - Professional labeling.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... water supply contains 0.3 to 0.7 ppm fluoride ion, reduce the dose to 2.5 mL of 0.02 percent or 5 mL of... labeling. (a) The labeling for anticaries fluoride treatment rinses identified in § 355.10(a)(3) and (c)(3) that are specially formulated so they may be swallowed (fluoride supplements) and are provided to...

  12. Validation of the Arizona Activity Frequency Questionnaire using doubly labeled water.

    PubMed

    Staten, L K; Taren, D L; Howell, W H; Tobar, M; Poehlman, E T; Hill, A; Reid, P M; Ritenbaugh, C

    2001-11-01

    Physical activity questionnaires (PAQs) are considered the most cost-efficient method to estimate total energy expenditure (TEE) in epidemiological studies. However, relatively few PAQs have been validated using doubly labeled water (DLW) in women or in samples with diverse ethnic backgrounds. This study was conducted to validate the Arizona Activity Frequency Questionnaire (AAFQ) for estimation of TEE and physical activity energy expenditure (PAEE) over 1 month using DLW as a reference method. Thirty-five relatively sedentary women completed the AAFQ before participating in an 8-d DLW protocol to measure TEE. TEE and PAEE were estimated from the AAFQ by calculating resting metabolic rate (RMR) using the equation of Mifflin et al. (AAFQmif), by measuring RMR using indirect calorimetry (AAFQic), and using MET conversion (AAFQmet). A predictive equation for TEE was generated. The mean +/- SD for TEE and PAEE from DLW were 9847 +/- 2555 kJ x d(-1) and 5578 +/- 2084 kJ x d(-1), respectively. Formulas using RMR to calculate the TEE and PAEE from the AAFQ tended to underestimate TEE and PAEE, whereas those that included only weight tended to overestimate TEE and PAEE. On the basis of the Mifflin et al. equation, the AAFQ tends to underestimate PAEE by 13%. This underestimation may be explained by the low lean body mass of the sample population and by effectiveness of the METs/RMR ratio in the obese. The following predictive equation was calculated: TEE (kJ x d(-1)) = (86.0 * average total daily METs) + (2.23 * RMRmif) - 6726. When the predictive equation is used, TEE calculated from the AAFQ is highly correlated with DLW TEE (adjusted r(2) = 0.70, P < 0.001). The AAFQ is an effective tool for the prediction of TEE and PAEE in epidemiological studies.

  13. Visualizing water molecules in transmembrane proteins using radiolytic labeling methods†

    PubMed Central

    Orban, Tivadar; Gupta, Sayan; Palczewski, Krzysztof; Chance, Mark R.

    2010-01-01

    Essential to cells and their organelles, water is both shuttled to where it is needed and trapped within cellular compartments and structures. Moreover, ordered waters within protein structures often co-localize with strategically placed polar or charged groups critical for protein function. Yet it is unclear if these ordered water molecules provide structural stabilization, mediate conformational changes in signaling, neutralize charged residues, or carry out a combination of all these functions. Structures of many integral membrane proteins, including G protein-coupled receptors (GPCRs), reveal the presence of ordered water molecules that may act like prosthetic groups in a manner quite unlike bulk water. Identification of ‘ordered’ waters within a crystalline protein structure requires sufficient occupancy of water to enable its detection in the protein's X-ray diffraction pattern and thus the observed waters likely represent a subset of tightly-bound functional waters. In this review, we highlight recent studies that suggest the structures of ordered waters within GPCRs are as conserved (and thus as important) as conserved side chains. In addition, methods of radiolysis, coupled to structural mass spectrometry (protein footprinting), reveal dynamic changes in water structure that mediate transmembrane signaling. The idea of water as a prosthetic group mediating chemical reaction dynamics is not new in fields such as catalysis. However, the concept of water as a mediator of conformational dynamics in signaling is just emerging, owing to advances in both crystallographic structure determination and new methods of protein footprinting. Although oil and water do not mix, understanding the roles of water is essential to understanding the function of membrane proteins. PMID:20047303

  14. WATER CHEMISTRY ASSESSMENT METHODS

    EPA Science Inventory

    This section summarizes and evaluates the surfce water column chemistry assessment methods for USEPA/EMAP-SW, USGS-NAQA, USEPA-RBP, Oho EPA, and MDNR-MBSS. The basic objective of surface water column chemistry assessment is to characterize surface water quality by measuring a sui...

  15. 40 CFR 600.115-11 - Criteria for determining the fuel economy label calculation method.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... economy label calculation method. 600.115-11 Section 600.115-11 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND GREENHOUSE GAS EXHAUST EMISSIONS OF MOTOR VEHICLES Fuel Economy and Carbon-Related Exhaust Emission Test Procedures § 600.115-11 Criteria for...

  16. 40 CFR 600.115-11 - Criteria for determining the fuel economy label calculation method.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... economy label calculation method. 600.115-11 Section 600.115-11 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND GREENHOUSE GAS EXHAUST EMISSIONS OF MOTOR VEHICLES Fuel Economy and Carbon-Related Exhaust Emission Test Procedures § 600.115-11 Criteria for...

  17. Multi-Label Learning via Random Label Selection for Protein Subcellular Multi-Locations Prediction.

    PubMed

    Wang, Xiao; Li, Guo-Zheng

    2013-03-12

    Prediction of protein subcellular localization is an important but challenging problem, particularly when proteins may simultaneously exist at, or move between, two or more different subcellular location sites. Most of the existing protein subcellular localization methods are only used to deal with the single-location proteins. In the past few years, only a few methods have been proposed to tackle proteins with multiple locations. However, they only adopt a simple strategy, that is, transforming the multi-location proteins to multiple proteins with single location, which doesn't take correlations among different subcellular locations into account. In this paper, a novel method named RALS (multi-label learning via RAndom Label Selection), is proposed to learn from multi-location proteins in an effective and efficient way. Through five-fold cross validation test on a benchmark dataset, we demonstrate our proposed method with consideration of label correlations obviously outperforms the baseline BR method without consideration of label correlations, indicating correlations among different subcellular locations really exist and contribute to improvement of prediction performance. Experimental results on two benchmark datasets also show that our proposed methods achieve significantly higher performance than some other state-of-the-art methods in predicting subcellular multi-locations of proteins. The prediction web server is available at http://levis.tongji.edu.cn:8080/bioinfo/MLPred-Euk/ for the public usage.

  18. Analysis of fluorescently labeled glycosphingolipid-derived oligosaccharides following ceramide glycanase digestion and anthranilic acid labeling.

    PubMed

    Neville, David C A; Coquard, Virginie; Priestman, David A; te Vruchte, Danielle J M; Sillence, Daniel J; Dwek, Raymond A; Platt, Frances M; Butters, Terry D

    2004-08-15

    Interest in cellular glycosphingolipid (GSL) function has necessitated the development of a rapid and sensitive method to both analyze and characterize the full complement of structures present in various cells and tissues. An optimized method to characterize oligosaccharides released from glycosphingolipids following ceramide glycanase digestion has been developed. The procedure uses the fluorescent compound anthranilic acid (2-aminobenzoic acid; 2-AA) to label oligosaccharides prior to analysis using normal-phase high-performance liquid chromatography. The labeling procedure is rapid, selective, and easy to perform and is based on the published method of Anumula and Dhume [Glycobiology 8 (1998) 685], originally used to analyze N-linked oligosaccharides. It is less time consuming than a previously published 2-aminobenzamide labeling method [Anal. Biochem. 298 (2001) 207] for analyzing GSL-derived oligosaccharides, as the fluorescent labeling is performed on the enzyme reaction mixture. The purification of 2-AA-labeled products has been improved to ensure recovery of oligosaccharides containing one to four monosaccharide units, which was not previously possible using the Anumula and Dhume post-derivatization purification procedure. This new approach may also be used to analyze both N- and O-linked oligosaccharides.

  19. 40 CFR 600.115-11 - Criteria for determining the fuel economy label calculation method.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Criteria for determining the fuel economy label calculation method. 600.115-11 Section 600.115-11 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND GREENHOUSE GAS EXHAUST EMISSIONS OF MOTOR...

  20. Combinatorial Labeling Method for Improving Peptide Fragmentation in Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Kuchibhotla, Bhanuramanand; Kola, Sankara Rao; Medicherla, Jagannadham V.; Cherukuvada, Swamy V.; Dhople, Vishnu M.; Nalam, Madhusudhana Rao

    2017-06-01

    Annotation of peptide sequence from tandem mass spectra constitutes the central step of mass spectrometry-based proteomics. Peptide mass spectra are obtained upon gas-phase fragmentation. Identification of the protein from a set of experimental peptide spectral matches is usually referred as protein inference. Occurrence and intensity of these fragment ions in the MS/MS spectra are dependent on many factors such as amino acid composition, peptide basicity, activation mode, protease, etc. Particularly, chemical derivatizations of peptides were known to alter their fragmentation. In this study, the influence of acetylation, guanidinylation, and their combination on peptide fragmentation was assessed initially on a lipase (LipA) from Bacillus subtilis followed by a bovine six protein mix digest. The dual modification resulted in improved fragment ion occurrence and intensity changes, and this resulted in the equivalent representation of b- and y-type fragment ions in an ion trap MS/MS spectrum. The improved representation has allowed us to accurately annotate the peptide sequences de novo. Dual labeling has significantly reduced the false positive protein identifications in standard bovine six peptide digest. Our study suggests that the combinatorial labeling of peptides is a useful method to validate protein identifications for high confidence protein inference. [Figure not available: see fulltext.

  1. A novel colloidal gold labeled antigen for the detection of Deoxynivalenol using an immunochromatographic assay method

    NASA Astrophysics Data System (ADS)

    Jin, Yu; Liu, Renrong; Zhu, Lixin; Chen, Zhenzhen

    2017-11-01

    In this paper, an immunochromatographic assay card was developed for the detection of DON in feed and cereals using a novel colloidal gold labeling method. For the colloidal gold immunochromatographic rapid detection (GICD) card, a monoclonal antibody DON-mAb and a goat anti-chicken IgY were drawn on NC membrane as the test line (T line) and the control line (C line) respectively. A gold labeled DON-CBSA conjugate and a gold labeled chicken IgY were sprayed onto the conjugate pad. The GICD card has cut-off levels of 50ng/mL for DON, which is invulnerable to matrix interference, and applicable to a wide range of samples. The GICD detecting results of feed and grain samples were compared with the results of ELISA testing, which showed good consistency.

  2. Dual Labeling Biotin Switch Assay to Reduce Bias Derived From Different Cysteine Subpopulations: A Method to Maximize S-Nitrosylation Detection.

    PubMed

    Chung, Heaseung Sophia; Murray, Christopher I; Venkatraman, Vidya; Crowgey, Erin L; Rainer, Peter P; Cole, Robert N; Bomgarden, Ryan D; Rogers, John C; Balkan, Wayne; Hare, Joshua M; Kass, David A; Van Eyk, Jennifer E

    2015-10-23

    S-nitrosylation (SNO), an oxidative post-translational modification of cysteine residues, responds to changes in the cardiac redox-environment. Classic biotin-switch assay and its derivatives are the most common methods used for detecting SNO. In this approach, the labile SNO group is selectively replaced with a single stable tag. To date, a variety of thiol-reactive tags have been introduced. However, these methods have not produced a consistent data set, which suggests an incomplete capture by a single tag and potentially the presence of different cysteine subpopulations. To investigate potential labeling bias in the existing methods with a single tag to detect SNO, explore if there are distinct cysteine subpopulations, and then, develop a strategy to maximize the coverage of SNO proteome. We obtained SNO-modified cysteine data sets for wild-type and S-nitrosoglutathione reductase knockout mouse hearts (S-nitrosoglutathione reductase is a negative regulator of S-nitrosoglutathione production) and nitric oxide-induced human embryonic kidney cell using 2 labeling reagents: the cysteine-reactive pyridyldithiol and iodoacetyl based tandem mass tags. Comparison revealed that <30% of the SNO-modified residues were detected by both tags, whereas the remaining SNO sites were only labeled by 1 reagent. Characterization of the 2 distinct subpopulations of SNO residues indicated that pyridyldithiol reagent preferentially labels cysteine residues that are more basic and hydrophobic. On the basis of this observation, we proposed a parallel dual-labeling strategy followed by an optimized proteomics workflow. This enabled the profiling of 493 SNO sites in S-nitrosoglutathione reductase knockout hearts. Using a protocol comprising 2 tags for dual-labeling maximizes overall detection of SNO by reducing the previously unrecognized labeling bias derived from different cysteine subpopulations. © 2015 American Heart Association, Inc.

  3. 16 CFR 305.13 - Labeling for ceiling fans.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... CONCERNING DISCLOSURES REGARDING ENERGY CONSUMPTION AND WATER USE OF CERTAIN HOME APPLIANCES AND OTHER PRODUCTS REQUIRED UNDER THE ENERGY POLICY AND CONSERVATION ACT (âAPPLIANCE LABELING RULEâ) Required Disclosures § 305.13 Labeling for ceiling fans. (a) Ceiling fans—(1) Content. Any covered product that is a...

  4. 16 CFR 305.13 - Labeling for ceiling fans.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... CONCERNING DISCLOSURES REGARDING ENERGY CONSUMPTION AND WATER USE OF CERTAIN HOME APPLIANCES AND OTHER PRODUCTS REQUIRED UNDER THE ENERGY POLICY AND CONSERVATION ACT (âAPPLIANCE LABELING RULEâ) Required Disclosures § 305.13 Labeling for ceiling fans. (a) Ceiling fans—(1) Content. Any covered product that is a...

  5. 16 CFR 305.13 - Labeling for ceiling fans.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... CONCERNING DISCLOSURES REGARDING ENERGY CONSUMPTION AND WATER USE OF CERTAIN HOME APPLIANCES AND OTHER PRODUCTS REQUIRED UNDER THE ENERGY POLICY AND CONSERVATION ACT (âAPPLIANCE LABELING RULEâ) Required Disclosures § 305.13 Labeling for ceiling fans. (a) Ceiling fans—(1) Content. Any covered product that is a...

  6. 16 CFR 305.13 - Labeling for ceiling fans.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... CONCERNING DISCLOSURES REGARDING ENERGY CONSUMPTION AND WATER USE OF CERTAIN HOME APPLIANCES AND OTHER PRODUCTS REQUIRED UNDER THE ENERGY POLICY AND CONSERVATION ACT (âAPPLIANCE LABELING RULEâ) Required Disclosures § 305.13 Labeling for ceiling fans. (a) Ceiling fans—(1) Content. Any covered product that is a...

  7. Ionomer-Membrane Water Processing Methods

    NASA Technical Reports Server (NTRS)

    MacCallum, Taber K. (Inventor); Kelsey, Laura (Inventor)

    2016-01-01

    This disclosure provides water processing apparatuses, systems, and methods for recovering water from wastewater such as urine. The water processing apparatuses, systems, and methods can utilize membrane technology for extracting purified water in a single step. A containment unit can include an ionomer membrane, such as Nafion(TradeMark) over a hydrophobic microporous membrane, such as polytetrafluoroethylene (PTFE). The containment unit can be filled with wastewater, and the hydrophobic microporous membrane can be impermeable to liquids and solids of the wastewater but permeable to gases and vapors of the wastewater, and the ionomer membrane can be permeable to water vapor but impermeable to one or more contaminants of the gases and vapors. The containment unit can be exposed to a dry purge gas to maintain a water vapor partial pressure differential to drive permeation of the water vapor, and the water vapor can be collected and processed into potable water.

  8. ALE: automated label extraction from GEO metadata.

    PubMed

    Giles, Cory B; Brown, Chase A; Ripperger, Michael; Dennis, Zane; Roopnarinesingh, Xiavan; Porter, Hunter; Perz, Aleksandra; Wren, Jonathan D

    2017-12-28

    NCBI's Gene Expression Omnibus (GEO) is a rich community resource containing millions of gene expression experiments from human, mouse, rat, and other model organisms. However, information about each experiment (metadata) is in the format of an open-ended, non-standardized textual description provided by the depositor. Thus, classification of experiments for meta-analysis by factors such as gender, age of the sample donor, and tissue of origin is not feasible without assigning labels to the experiments. Automated approaches are preferable for this, primarily because of the size and volume of the data to be processed, but also because it ensures standardization and consistency. While some of these labels can be extracted directly from the textual metadata, many of the data available do not contain explicit text informing the researcher about the age and gender of the subjects with the study. To bridge this gap, machine-learning methods can be trained to use the gene expression patterns associated with the text-derived labels to refine label-prediction confidence. Our analysis shows only 26% of metadata text contains information about gender and 21% about age. In order to ameliorate the lack of available labels for these data sets, we first extract labels from the textual metadata for each GEO RNA dataset and evaluate the performance against a gold standard of manually curated labels. We then use machine-learning methods to predict labels, based upon gene expression of the samples and compare this to the text-based method. Here we present an automated method to extract labels for age, gender, and tissue from textual metadata and GEO data using both a heuristic approach as well as machine learning. We show the two methods together improve accuracy of label assignment to GEO samples.

  9. Using Fluorescent Viruses for Detecting Bacteria in Water

    NASA Technical Reports Server (NTRS)

    Tabacco, Mary Beth; Qian, Xiaohua; Russo, Jaimie A.

    2009-01-01

    A method of detecting water-borne pathogenic bacteria is based partly on established molecular-recognition and fluorescent-labeling concepts, according to which bacteria of a species of interest are labeled with fluorescent reporter molecules and the bacteria can then be detected by fluorescence spectroscopy. The novelty of the present method lies in the use of bacteriophages (viruses that infect bacteria) to deliver the fluorescent reporter molecules to the bacteria of the species of interest.

  10. A simple method for comparing immunogold distributions in two or more experimental groups illustrated using GLUT1 labelling of isolated trophoblast cells.

    PubMed

    Mayhew, T M; Desoye, G

    2004-07-01

    Colloidal gold-labelling, combined with transmission electron microscopy, is a valuable technique for high-resolution immunolocalization of identified antigens in different subcellular compartments. Whilst the technique has been applied to placental tissues, few quantitative studies have been made. Subcellular compartments exist in three main categories (viz. organelles, membranes, filaments/tubules) and this affects the possibilities for quantification. Generally, gold particles are counted in order to compare either (a) compartments within an experimental group or (b) compartmental labelling distributions between groups. For the former, recent developments make it possible to test whether or not there is differential (nonrandom) labelling of compartments. The methods (relative labelling index and labelling density) are ideally suited to analysing label in one category of compartment (organelle or membrane or filament) but may be adapted to deal with a mixture of categories. They also require information about compartment size (e.g. profile area or trace length). Here, a simple and efficient method for drawing between-group comparisons of labelling distributions is presented. The method does not require information about compartment size or specimen magnification. It relies on multistage random sampling of specimens and unbiased counting of gold particles associated with different compartments. Distributions of observed gold counts in different experimental groups are compared by contingency table analysis with degrees of freedom for chi-squared (chi(2)) values being determined by the numbers of compartments and experimental groups. Compartmental values of chi(2)which contribute substantially to total chi(2)identify the principal subcellular sites of between-group differences. The method is illustrated using datasets from immunolabelling studies on the localization of GLUT1 glucose transporters in cultured human trophoblast cells exposed to different treatments.

  11. Affordable measurement of human total energy expenditure and body composition using one-tenth dose doubly labelled water.

    PubMed

    Mann, D V; Ho, C S; Critchley, L; Fok, B S P; Pang, E W H; Lam, C W K; Hjelm, N M

    2007-05-01

    The doubly labelled water (DLW) method is the technique of choice for measurement of free-living total energy expenditure (TEE) in humans. A major constraint on the clinical applicability of the method has been the expense of the (18)O isotope. We have used a reduced-dose (one-tenth of the currently recommended standard dose) of DLW for the measurement of TEE and body composition in nine healthy adult male volunteers. TEE measured by reduced-dose DLW was positively correlated with resting energy expenditure measured by metabolic cart (r=0.87, P<0.01). Isotope-derived fat mass and body mass index were strongly correlated (r=0.86, P<0.01). In four subjects in whom we performed a complementary evaluation using standard-dose isotope enrichment, the TEE measurements were satisfactorily comparable (mean+/-s.d.: reduced dose 2586+/-155 kcal/day vs standard dose 2843+/-321 kcal/day; mean difference 257+/-265 kcal/day). These data indicate that DLW measurements of human energy expenditure and body composition can be performed at a substantially reduced dose (and cost) of isotope enrichment than is currently employed.

  12. Category labels versus feature labels: category labels polarize inferential predictions.

    PubMed

    Yamauchi, Takashi; Yu, Na-Yung

    2008-04-01

    What makes category labels different from feature labels in predictive inference? This study suggests that category labels tend to make inductive reasoning polarized and homogeneous. In two experiments, participants were shown two schematic pictures of insects side by side and predicted the value of a hidden feature of one insect on the basis of the other insect. Arbitrary verbal labels were shown above the two pictures, and the meanings of the labels were manipulated in the instructions. In one condition, the labels represented the category membership of the insects, and in the other conditions, the same labels represented attributes of the insects. When the labels represented category membership, participants' responses became substantially polarized and homogeneous, indicating that the mere reference to category membership can modify reasoning processes.

  13. The bubble method of water purification

    NASA Astrophysics Data System (ADS)

    Smirnov, B. M.; Babaeva, N. Yu.; Naidis, G. V.; Panov, V. A.; Saveliev, A. S.; Son, E. E.; Tereshonok, D. V.

    2018-02-01

    The processes of water purification from admixture molecules are analyzed. The purification rate is limited due to a low diffusion coefficient of the admixture molecules in water. At non-small concentrations of the admixture molecules, the water purication can proceed through association of molecules in condensed nanoparticles which fall on the bottom of the water volume. The rate of association may be increased in an external electric field, but in reality this cannot change significantly the rate of the purification process. The bubble method of water purification is considered, where air bubbles formed at the bottom of the water volume, transfer admixture molecules to the interface. This method allows one to clean small water volumes fast. This mechanism of water purification is realized experimentally and exhibits the promises of the bubble purification method.

  14. Learning with imperfectly labeled patterns

    NASA Technical Reports Server (NTRS)

    Chittineni, C. B.

    1979-01-01

    The problem of learning in pattern recognition using imperfectly labeled patterns is considered. The performance of the Bayes and nearest neighbor classifiers with imperfect labels is discussed using a probabilistic model for the mislabeling of the training patterns. Schemes for training the classifier using both parametric and non parametric techniques are presented. Methods for the correction of imperfect labels were developed. To gain an understanding of the learning process, expressions are derived for success probability as a function of training time for a one dimensional increment error correction classifier with imperfect labels. Feature selection with imperfectly labeled patterns is described.

  15. The Leucine Incorporation Method Estimates Bacterial Growth Equally Well in Both Oxic and Anoxic Lake Waters

    PubMed Central

    Bastviken, David; Tranvik, Lars

    2001-01-01

    Bacterial biomass production is often estimated from incorporation of radioactively labeled leucine into protein, in both oxic and anoxic waters and sediments. However, the validity of the method in anoxic environments has so far not been tested. We compared the leucine incorporation of bacterial assemblages growing in oxic and anoxic waters from three lakes differing in nutrient and humic contents. The method was modified to avoid O2 contamination by performing the incubation in syringes. Isotope saturation levels in oxic and anoxic waters were determined, and leucine incorporation rates were compared to microscopically observed bacterial growth. Finally, we evaluated the effects of O2 contamination during incubation with leucine, as well as the potential effects of a headspace in the incubation vessel. Isotope saturation occurred at a leucine concentration of above about 50 nM in both oxic and anoxic waters from all three lakes. Leucine incorporation rates were linearly correlated to observed growth, and there was no significant difference between oxic and anoxic conditions. O2 contamination of anoxic water during 1-h incubations with leucine had no detectable impact on the incorporation rate, while a headspace in the incubation vessel caused leucine incorporation to increase in both anoxic and O2-contaminated samples. The results indicate that the leucine incorporation method relates equally to bacterial growth rates under oxic and anoxic conditions and that incubation should be performed without a headspace. PMID:11425702

  16. Functionalized magnetic-fluorescent hybrid nanoparticles for cell labelling.

    PubMed

    Lou, Lei; Yu, Ke; Zhang, Zhengli; Li, Bo; Zhu, Jianzhong; Wang, Yiting; Huang, Rong; Zhu, Ziqiang

    2011-05-01

    A facile method of synthesizing 60 nm magnetic-fluorescent core-shell bifunctional nanocomposites with the ability to label cells is presented. Hydrophobic trioctylphosphine oxide (TOPO)-capped CdSe@ZnS quantum dots (QDs) were assembled on polyethyleneimine (PEI)-coated Fe(3)O(4) nanoparticles (MNP). Polyethyleneimine was utilized for the realization of multifunction, including attaching 4 nm TOPO capped CdSe@ZnS quantum dots onto magnetite particles, altering the surface properties of quantum dots from hydrophobic to hydrophilic as well as preventing the formation of large aggregates. Results show that these water-soluble hybrid nanocomposites exhibit good colloidal stability and retain good magnetic and fluorescent properties. Because TOPO-capped QDs are assembled instead of their water-soluble equivalents, the nanocomposites are still highly luminescent with no shift in the PL peak position and present long-term fluorescence stability. Moreover, TAT peptide (GRKKRRQRRRPQ) functionalized hybrid nanoparticles were also studied due to their combined magnetic enrichment and optical detection for cell separation and rapid cell labelling. A cell viability assay revealed good biocompatibility of these hybrid nanoparticles. The potential application of the new magnetic-fluorescent nanocomposites in biological and medicine is demonstrated. © The Royal Society of Chemistry 2011

  17. Statistical methods for quantitative mass spectrometry proteomic experiments with labeling.

    PubMed

    Oberg, Ann L; Mahoney, Douglas W

    2012-01-01

    Mass Spectrometry utilizing labeling allows multiple specimens to be subjected to mass spectrometry simultaneously. As a result, between-experiment variability is reduced. Here we describe use of fundamental concepts of statistical experimental design in the labeling framework in order to minimize variability and avoid biases. We demonstrate how to export data in the format that is most efficient for statistical analysis. We demonstrate how to assess the need for normalization, perform normalization, and check whether it worked. We describe how to build a model explaining the observed values and test for differential protein abundance along with descriptive statistics and measures of reliability of the findings. Concepts are illustrated through the use of three case studies utilizing the iTRAQ 4-plex labeling protocol.

  18. Isotope dilution liquid chromatography - mass spectrometry methods for fat- and water-soluble vitamins in nutritional formulations.

    PubMed

    Phinney, Karen W; Rimmer, Catherine A; Thomas, Jeanice Brown; Sander, Lane C; Sharpless, Katherine E; Wise, Stephen A

    2011-01-01

    Vitamins are essential to human health, and dietary supplements containing vitamins are widely used by individuals hoping to ensure they have adequate intake of these important nutrients. Measurement of vitamins in nutritional formulations is necessary to monitor regulatory compliance and in studies examining the nutrient intake of specific populations. Liquid chromatographic methods, primarily with UV absorbance detection, are well established for both fat- and water-soluble measurements, but they do have limitations for certain analytes and may suffer from a lack of specificity in complex matrices. Liquid chromatography-mass spectrometry (LC-MS) provides both sensitivity and specificity for the determination of vitamins in these matrices, and simultaneous analysis of multiple vitamins in a single analysis is often possible. In this work, LC-MS methods were developed for both fat- and water-soluble vitamins and applied to the measurement of these analytes in two NIST Standard Reference Materials. When possible, stable isotope labeled internal standards were employed for quantification.

  19. Energetics during hatchling dispersal of the olive ridley turtle Lepidochelys olivacea using doubly labeled water.

    PubMed

    Clusella Trullas, Susana; Spotila, James R; Paladino, Frank V

    2006-01-01

    Studies of metabolism are central to the understanding of the ecology, behavior, and evolution of reptiles. This study focuses on one phase of the sea turtle life cycle, hatchling dispersal, and gives insight into energetic constraints that dispersal imposes on hatchlings. Hatchling dispersal is an energetically expensive phase in the life cycle of the olive ridley turtle Lepidochelys olivacea. Field metabolic rates (FMRs), determined using the doubly labeled water (DLW) method, for L. olivacea hatchlings digging out of their nest chamber, crawling at the sand surface, and swimming were five, four, and seven times, respectively, the resting metabolic rate (RMR). The cost of swimming was 1.5 and 1.8 times the cost of the digging and crawling phases, respectively, and we estimated that if L. olivacea hatchlings swim at frenzy levels, they can rely on yolk reserves to supply energy for only 3-6 d once they reach the ocean. We compared our RMR and FMR values by establishing an interspecific RMR mass-scaling relationship for a wide range of species in the order Testudines and found a scaling exponent of 1.06. This study demonstrates the feasibility of using the DLW method to estimate energetic costs of free-living sea turtle hatchlings and emphasizes the need for metabolic studies in various life-history stages.

  20. Portion Size Labeling and Intended Soft Drink Consumption: The Impact of Labeling Format and Size Portfolio

    ERIC Educational Resources Information Center

    Vermeer, Willemijn M.; Steenhuis, Ingrid H. M.; Leeuwis, Franca H.; Bos, Arjan E. R.; de Boer, Michiel; Seidell, Jacob C.

    2010-01-01

    Objective: To assess what portion size labeling "format" is most promising in helping consumers selecting appropriate soft drink sizes, and whether labeling impact depends on the size portfolio. Methods: An experimental study was conducted in fast-food restaurants in which 2 labeling formats (ie, reference portion size and small/medium/large…

  1. Total energy expenditure in the Yakut (Sakha) of Siberia as measured by the doubly labeled water method.

    PubMed

    Snodgrass, J Josh; Leonard, William R; Tarskaia, Larissa A; Schoeller, Dale A

    2006-10-01

    Populations in transition to a Western lifestyle display increased incidences of obesity, type 2 diabetes, and other chronic diseases; the mechanisms responsible for these changes, however, remain incompletely understood. Although reduced physical activity has been implicated, few studies have accurately quantified energy expenditure in subsistence populations. The aim of the study was to examine the relation of total energy expenditure (TEE) and activity [physical activity level (PAL), activity energy expenditure (AEE), and weight-adjusted AEE (AEE/kg)] with body composition and lifestyle in the Yakut (Sakha), an indigenous high-latitude Siberian group. We measured TEE using doubly labeled water and resting metabolic rate using indirect calorimetry in 28 young adults (14 women and 14 men) from Berdygestiakh, Russia. The men had higher TEE (12,983 compared with 9620 kJ/d; P < 0.01), AEE (5248 compared with 3203 kJ/d; P < 0.05), AEE/kg (72.7 compared with 48.8 kJ . kg(-1) . d(-1); P < 0.05), and PAL (1.7 compared with 1.5; P = 0.09) than did the women, although this may reflect, in part, body size and composition differences. Overweight men and women had modestly higher TEEs than did lean participants; when adjusted for body size, activity levels were not significantly different between the groups. Persons with more traditional lifestyles had higher TEEs and PALs than did persons with more modernized lifestyles; this difference correlated with differences in participation in subsistence activities. Activity levels in the Yakut were lower than those in other subsistence groups, especially the women, and were not significantly different from those in persons in industrialized nations. Persons who participated in more subsistence activities and consumed fewer market foods had significantly higher activity levels.

  2. SAIL--stereo-array isotope labeling.

    PubMed

    Kainosho, Masatsune; Güntert, Peter

    2009-11-01

    Optimal stereospecific and regiospecific labeling of proteins with stable isotopes enhances the nuclear magnetic resonance (NMR) method for the determination of the three-dimensional protein structures in solution. Stereo-array isotope labeling (SAIL) offers sharpened lines, spectral simplification without loss of information and the ability to rapidly collect and automatically evaluate the structural restraints required to solve a high-quality solution structure for proteins up to twice as large as before. This review gives an overview of stable isotope labeling methods for NMR spectroscopy with proteins and provides an in-depth treatment of the SAIL technology.

  3. Interactions of 14C-labeled multi-walled carbon nanotubes with soil minerals in water.

    PubMed

    Zhang, Liwen; Petersen, Elijah J; Zhang, Wen; Chen, Yongsheng; Cabrera, Miguel; Huang, Qingguo

    2012-07-01

    Carbon nanotubes are often modified to be stable in the aqueous phase by adding extensive hydrophilic surface functional groups. The stability of such CNTs in water with soil or sediment is one critical factor controlling their environmental fate. We conducted a series of experiments to quantitatively assess the association between water dispersed multi-walled carbon nanotubes (MWCNTs) and three soil minerals (kaolinite, smectite, or shale) in aqueous solution under different sodium concentrations. (14)C-labeling was used in these experiments to unambiguously quantify MWCNTs. The results showed that increasing ionic strength strongly promoted the removal of MWCNTs from aqueous phase. The removal tendency is inversely correlated with the soil minerals' surface potential and directly correlated with their hydrophobicity. This removal can be interpreted by the extended Derjaguin-Landau-Verwey-Overbeek (EDLVO) theory especially for kaolinite and smectite. Shale, which contains large and insoluble organic materials, sorbed MWCNTs the most strongly. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. A novel geometry-dosimetry label fusion method in multi-atlas segmentation for radiotherapy: a proof-of-concept study

    NASA Astrophysics Data System (ADS)

    Chang, Jina; Tian, Zhen; Lu, Weiguo; Gu, Xuejun; Chen, Mingli; Jiang, Steve B.

    2017-05-01

    Multi-atlas segmentation (MAS) has been widely used to automate the delineation of organs at risk (OARs) for radiotherapy. Label fusion is a crucial step in MAS to cope with the segmentation variabilities among multiple atlases. However, most existing label fusion methods do not consider the potential dosimetric impact of the segmentation result. In this proof-of-concept study, we propose a novel geometry-dosimetry label fusion method for MAS-based OAR auto-contouring, which evaluates the segmentation performance in terms of both geometric accuracy and the dosimetric impact of the segmentation accuracy on the resulting treatment plan. Differently from the original selective and iterative method for performance level estimation (SIMPLE), we evaluated and rejected the atlases based on both Dice similarity coefficient and the predicted error of the dosimetric endpoints. The dosimetric error was predicted using our previously developed geometry-dosimetry model. We tested our method in MAS-based rectum auto-contouring on 20 prostate cancer patients. The accuracy in the rectum sub-volume close to the planning tumor volume (PTV), which was found to be a dosimetric sensitive region of the rectum, was greatly improved. The mean absolute distance between the obtained contour and the physician-drawn contour in the rectum sub-volume 2 mm away from PTV was reduced from 3.96 mm to 3.36 mm on average for the 20 patients, with the maximum decrease found to be from 9.22 mm to 3.75 mm. We also compared the dosimetric endpoints predicted for the obtained contours with those predicted for the physician-drawn contours. Our method led to smaller dosimetric endpoint errors than the SIMPLE method in 15 patients, comparable errors in 2 patients, and slightly larger errors in 3 patients. These results indicated the efficacy of our method in terms of considering both geometric accuracy and dosimetric impact during label fusion. Our algorithm can be applied to different tumor sites

  5. A novel geometry-dosimetry label fusion method in multi-atlas segmentation for radiotherapy: a proof-of-concept study.

    PubMed

    Chang, Jina; Tian, Zhen; Lu, Weiguo; Gu, Xuejun; Chen, Mingli; Jiang, Steve B

    2017-05-07

    Multi-atlas segmentation (MAS) has been widely used to automate the delineation of organs at risk (OARs) for radiotherapy. Label fusion is a crucial step in MAS to cope with the segmentation variabilities among multiple atlases. However, most existing label fusion methods do not consider the potential dosimetric impact of the segmentation result. In this proof-of-concept study, we propose a novel geometry-dosimetry label fusion method for MAS-based OAR auto-contouring, which evaluates the segmentation performance in terms of both geometric accuracy and the dosimetric impact of the segmentation accuracy on the resulting treatment plan. Differently from the original selective and iterative method for performance level estimation (SIMPLE), we evaluated and rejected the atlases based on both Dice similarity coefficient and the predicted error of the dosimetric endpoints. The dosimetric error was predicted using our previously developed geometry-dosimetry model. We tested our method in MAS-based rectum auto-contouring on 20 prostate cancer patients. The accuracy in the rectum sub-volume close to the planning tumor volume (PTV), which was found to be a dosimetric sensitive region of the rectum, was greatly improved. The mean absolute distance between the obtained contour and the physician-drawn contour in the rectum sub-volume 2 mm away from PTV was reduced from 3.96 mm to 3.36 mm on average for the 20 patients, with the maximum decrease found to be from 9.22 mm to 3.75 mm. We also compared the dosimetric endpoints predicted for the obtained contours with those predicted for the physician-drawn contours. Our method led to smaller dosimetric endpoint errors than the SIMPLE method in 15 patients, comparable errors in 2 patients, and slightly larger errors in 3 patients. These results indicated the efficacy of our method in terms of considering both geometric accuracy and dosimetric impact during label fusion. Our algorithm can be applied to different tumor sites

  6. Simple, rapid method for the preparation of isotopically labeled formaldehyde

    DOEpatents

    Hooker, Jacob Matthew [Port Jefferson, NY; Schonberger, Matthias [Mains, DE; Schieferstein, Hanno [Aabergen, DE; Fowler, Joanna S [Bellport, NY

    2011-10-04

    Isotopically labeled formaldehyde (*C.sup..sctn.H.sub.2O) is prepared from labeled methyl iodide (*C.sup..sctn.H.sub.3I) by reaction with an oxygen nucleophile having a pendant leaving group. The mild and efficient reaction conditions result in good yields of *C.sup..sctn.H.sub.2O with little or no *C isotopic dilution. The simple, efficient production of .sup.11CH.sub.2O is described. The use of the .sup.11CH.sub.2O for the formation of positron emission tomography tracer compounds is described. The reaction can be incorporated into automated equipment available to radiochemistry laboratories. The isotopically labeled formaldehyde can be used in a variety of reactions to provide radiotracer compounds for imaging studies as well as for scintillation counting and autoradiography.

  7. A Comparison of Methods for Teaching Receptive Labeling to Children with Autism Spectrum Disorders: A Systematic Replication

    ERIC Educational Resources Information Center

    Grow, Laura L.; Kodak, Tiffany; Carr, James E.

    2014-01-01

    Previous research has demonstrated that the conditional-only method (starting with a multiple-stimulus array) is more efficient than the simple-conditional method (progressive incorporation of more stimuli into the array) for teaching receptive labeling to children with autism spectrum disorders (Grow, Carr, Kodak, Jostad, & Kisamore, 2011).…

  8. Rapid electrochemical detection of polyaniline-labeled Escherichia coli O157:H7.

    PubMed

    Setterington, Emma B; Alocilja, Evangelyn C

    2011-01-15

    There is a high demand for rapid, sensitive, and field-ready detection methods for Escherichia coli O157:H7, a highly infectious and potentially fatal food and water borne pathogen. In this study, E. coli O157:H7 cells are isolated via immunomagnetic separation (IMS) and labeled with biofunctionalized electroactive polyaniline (immuno-PANI). Labeled cell complexes are deposited onto a disposable screen-printed carbon electrode (SPCE) sensor and pulled to the electrode surface by an external magnetic field, to amplify the electrochemical signal generated by the polyaniline. Cyclic voltammetry is used to detect polyaniline and signal magnitude indicates the presence or absence of E. coli O157:H7. As few as 7CFU of E. coli O157:H7 (corresponding to an original concentration of 70 CFU/ml) were successfully detected on the SPCE sensor. The assay requires 70 min from sampling to detection, giving it a major advantage over standard culture methods in applications requiring high-throughput screening of samples and rapid results. The method can be performed with portable, handheld instrumentation and no biological modification of the sensor surface is required. Potential applications include field-based pathogen detection for food and water safety, environmental monitoring, healthcare, and biodefense. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. Characteristics of women who frequently under report their energy intake: a doubly labelled water study.

    PubMed

    Scagliusi, F B; Ferriolli, E; Pfrimer, K; Laureano, C; Cunha, C S F; Gualano, B; Lourenço, B H; Lancha, A H

    2009-10-01

    We applied three dietary assessment methods and aimed at obtaining a set of physical, social and psychological variables that can discriminate those individuals who did not underreport ('never under-reporters'), those who underreported in one dietary assessment method ('occasional under-reporters') and those who underreported in two or three dietary assessment methods ('frequent under-reporters'). Sixty-five women aged 18-57 years were recruited for this study. Total energy expenditure was determined by doubly labelled water, and energy intake was estimated by three 24-h diet recalls, 3-day food records and a food frequency questionnaire. A multiple discriminant analysis was used to identify which of those variables better discriminated the three groups: body mass index (BMI), income, education, social desirability, nutritional knowledge, dietary restraint, physical activity practice, body dissatisfaction and binge-eating symptoms. Twenty-three participants were 'never under-reporters'. Twenty-four participants were 'occasional under-reporters' and 18 were 'frequent under-reporters'. Four variables entered the discriminant model: income, BMI, social desirability and body dissatisfaction. According to potency indices, income contributed the most to the total discriminant power, followed in decreasing order by social desirability score, BMI and body dissatisfaction. Income, social desirability and BMI were the characteristics that mainly separated the 'never under-reporters' from the under-reporters (occasional or frequent). Body dissatisfaction better discriminated the 'occasional under-reporters' from the 'frequent under-reporters'. 'Frequent under-reporters' have a greater BMI, social desirability score, body dissatisfaction score and lower income. These four variables seemed to be able to discriminate individuals who are more prone to systematic under reporting.

  10. New method for the selective labeling of erythrocytes in whole blood with Tc-99m

    DOEpatents

    Srivastava, S.C.; Babich, J.W.; Straub, R.; Richards, P.

    1984-01-27

    Method and kit are described for the preparation of /sup 99m/Tc labeled red blood cells using whole blood in a closed sterile system containing stannous tin in a form such that it will enter the red blood cells and be available therein for the reduction of technetium.

  11. 16 CFR 305.11 - Labeling for refrigerators, refrigerator-freezers, freezers, dishwashers, clothes washers, water...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... immediate consumer recognition and readability. Trim size dimensions for all labels shall be as follows... on the label. Specific sizes and faces to be used are indicated on the prototype labels. No...

  12. Gold Nanoparticle Labels Amplify Ellipsometric Signals

    NASA Technical Reports Server (NTRS)

    Venkatasubbarao, Srivatsa

    2008-01-01

    The ellipsometric method reported in the immediately preceding article was developed in conjunction with a method of using gold nanoparticles as labels on biomolecules that one seeks to detect. The purpose of the labeling is to exploit the optical properties of the gold nanoparticles in order to amplify the measurable ellipsometric effects and thereby to enable ultrasensitive detection of the labeled biomolecules without need to develop more-complex ellipsometric instrumentation. The colorimetric, polarization, light-scattering, and other optical properties of nanoparticles depend on their sizes and shapes. In the present method, these size-and-shape-dependent properties are used to magnify the polarization of scattered light and the diattenuation and retardance of signals derived from ellipsometry. The size-and-shape-dependent optical properties of the nanoparticles make it possible to interrogate the nanoparticles by use of light of various wavelengths, as appropriate, to optimally detect particles of a specific type at high sensitivity. Hence, by incorporating gold nanoparticles bound to biomolecules as primary or secondary labels, the performance of ellipsometry as a means of detecting the biomolecules can be improved. The use of gold nanoparticles as labels in ellipsometry has been found to afford sensitivity that equals or exceeds the sensitivity achieved by use of fluorescence-based methods. Potential applications for ellipsometric detection of gold nanoparticle-labeled biomolecules include monitoring molecules of interest in biological samples, in-vitro diagnostics, process monitoring, general environmental monitoring, and detection of biohazards.

  13. Total energy expenditure in adults with cerebral palsy as assessed by doubly labeled water.

    PubMed

    Johnson, R K; Hildreth, H G; Contompasis, S H; Goran, M I

    1997-09-01

    To characterize total energy expenditure (TEE) in free-living adults with cerebral palsy (CP) using the doubly labeled water technique, and to determine those physiologic variables and characteristics of CP that were markers of TEE in adults with CP. TEE was measured using the doubly labeled water technique in 30 free-living adults with CP (12 women, 18 men). To determine the best markers of TEE, the following factors were examined: CP status, resting metabolic rate (RMR), anthropometric characteristics and body composition by means of dual-energy x-ray absorptiometry (DXA) and skinfold thickness measurements, energy cost of leisure-time activities, and oral-motor impairment. Means +/- standard deviations, t tests, Pearson product-moment correlation coefficients, Spearman rank correlation coefficients, chi 2, stepwise multiple-correlation regression analysis, and analysis of covariance were used to examine the relationships among variables of interest. TEE was highly variable in the sample (mean = 2,455 +/- 622 kcal/day for men and 1,986 +/- 363 kcal/day for women). Stepwise regression analysis showed that TEE was best predicted in the sample by RMR, percentage body fat determined by DXA, ambulation status, and sex (multiple R = .68, P = .003). When practical, easily measured variables were used, TEE was best predicted by height, ambulation status, percentage body fat by skinfold thickness measurements, and sex (multiple R = .61, P. = 018). The contribution of energy expended in physical activity to TEE was significantly higher in the ambulatory subjects than the nonambulatory subjects (25% vs 16%, respectively; P = .009). The high degree of variability in TEE, largely attributable to high interindividual variation in energy expended in physical activity, makes it difficult to provide general guidelines for energy requirements for adults with CP. Because ambulation status was an important predictor of TEE, it must be accounted for in estimating energy requirements

  14. Two efficient label-equivalence-based connected-component labeling algorithms for 3-D binary images.

    PubMed

    He, Lifeng; Chao, Yuyan; Suzuki, Kenji

    2011-08-01

    Whenever one wants to distinguish, recognize, and/or measure objects (connected components) in binary images, labeling is required. This paper presents two efficient label-equivalence-based connected-component labeling algorithms for 3-D binary images. One is voxel based and the other is run based. For the voxel-based one, we present an efficient method of deciding the order for checking voxels in the mask. For the run-based one, instead of assigning each foreground voxel, we assign each run a provisional label. Moreover, we use run data to label foreground voxels without scanning any background voxel in the second scan. Experimental results have demonstrated that our voxel-based algorithm is efficient for 3-D binary images with complicated connected components, that our run-based one is efficient for those with simple connected components, and that both are much more efficient than conventional 3-D labeling algorithms.

  15. Preparation of tritium- or deuterium-labeled vitamin D analogs by a convenient general method*

    PubMed Central

    Paaren, Herbert E.; Fivizzani, Mary A.; Schnoes, Heinrich K.; DeLuca, Hector F.

    1981-01-01

    The three-step conversion of vitamin D analogs to 6-oxo-3,5-cyclovitamin D derivatives followed by reduction with a tritide or deuteride reagent and subsequent cycloreversion gives 6-tritio(deutero)vitamin D derivatives and corresponding 5,6-trans-analogs. The method is general and affords the 6-labeled-vitamin D analogs in ≈20% overall yield. PMID:6273856

  16. Synthesis and Labeling of RNA In Vitro

    PubMed Central

    Huang, Chao; Yu, Yi-Tao

    2013-01-01

    This unit discusses several methods for generating large amounts of uniformly labeled, end-labeled, and site-specifically labeled RNAs in vitro. The methods involve a number of experimental procedures, including RNA transcription, 5′ dephosphorylation and rephosphorylation, 3′ terminal nucleotide addition (via ligation), site-specific RNase H cleavage directed by 2′-O-methyl RNA-DNA chimeras, and 2-piece splint ligation. The applications of these RNA radiolabeling approaches are also discussed. PMID:23547015

  17. Extrinsic labeling method may not accurately measure Fe absorption from cooked pinto beans (Phaseolus vulgaris): comparison of extrinsic and intrinsic labeling of beans.

    PubMed

    Jin, Fuxia; Cheng, Zhiqiang; Rutzke, Michael A; Welch, Ross M; Glahn, Raymond P

    2008-08-27

    Isotopic labeling of food has been widely used for the measurement of Fe absorption in determining requirements and evaluating the factors involved in Fe bioavailability. An extrinsic labeling technique will not accurately predict the total Fe absorption from foods unless complete isotopic exchange takes place between an extrinsically added isotope label and the intrinsic Fe of the food. We examined isotopic exchange in the case of both white beans and colored beans (Phaseolus vulgaris) with an in vitro digestion model. There are significant differences in (58)Fe/(56)Fe ratios between the sample digest supernatant and the pellet of extrinsically labeled pinto bean. The white bean digest shows significantly better equilibration of the extrinsic (58)Fe with the intrinsic (56)Fe. In contrast to the extrinsically labeled samples, both white and red beans labeled intrinsically with (58)Fe demonstrated consistent ratios of (58)Fe/(56)Fe in the bean meal, digest, supernatant, and pellet. It is possible that the polyphenolics in the bean seed coat may bind Fe and thus interfere with extrinsic labeling of the bean meals. These observations raise questions on the accuracy of studies that used extrinsic tags to measure Fe absorption from beans. Intrinsic labeling appears necessary to accurately measure Fe bioavailability from beans.

  18. To label or not to label: applications of quantitative proteomics in neuroscience research.

    PubMed

    Filiou, Michaela D; Martins-de-Souza, Daniel; Guest, Paul C; Bahn, Sabine; Turck, Christoph W

    2012-02-01

    Proteomics has provided researchers with a sophisticated toolbox of labeling-based and label-free quantitative methods. These are now being applied in neuroscience research where they have already contributed to the elucidation of fundamental mechanisms and the discovery of candidate biomarkers. In this review, we evaluate and compare labeling-based and label-free quantitative proteomic techniques for applications in neuroscience research. We discuss the considerations required for the analysis of brain and central nervous system specimens, the experimental design of quantitative proteomic workflows as well as the feasibility, advantages, and disadvantages of the available techniques for neuroscience-oriented questions. Furthermore, we assess the use of labeled standards as internal controls for comparative studies in humans and review applications of labeling-based and label-free mass spectrometry approaches in relevant model organisms and human subjects. Providing a comprehensive guide of feasible and meaningful quantitative proteomic methodologies for neuroscience research is crucial not only for overcoming current limitations but also for gaining useful insights into brain function and translating proteomics from bench to bedside. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Stable Isotope Labeling Strategy for Curcumin Metabolite Study in Human Liver Microsomes by Liquid Chromatography-Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Gao, Dan; Chen, Xiaowu; Yang, Xiaomei; Wu, Qin; Jin, Feng; Wen, Hongliang; Jiang, Yuyang; Liu, Hongxia

    2015-04-01

    The identification of drug metabolites is very important in drug development. Nowadays, the most widely used methods are isotopes and mass spectrometry. However, the commercial isotopic labeled reagents are usually very expensive, and the rapid and convenient identification of metabolites is still difficult. In this paper, an 18O isotope labeling strategy was developed and the isotopes were used as a tool to identify drug metabolites using mass spectrometry. Curcumin was selected as a model drug to evaluate the established method, and the 18O labeled curcumin was successfully synthesized. The non-labeled and 18O labeled curcumin were simultaneously metabolized in human liver microsomes (HLMs) and analyzed by liquid chromatography/mass spectrometry (LC-MS). The two groups of chromatograms obtained from metabolic reaction mixture with and without cofactors were compared and analyzed using Metabolynx software (Waters Corp., Milford, MA, USA). The mass spectra of the newly appearing chromatographic peaks in the experimental sample were further analyzed to find the metabolite candidates. Their chemical structures were confirmed by tandem mass spectrometry. Three metabolites, including two reduction products and a glucuronide conjugate, were successfully detected under their specific HLMs metabolic conditions, which were in accordance with the literature reported results. The results demonstrated that the developed isotope labeling method, together with post-acquisition data processing using Metabolynx software, could be used for fast identification of new drug metabolites.

  20. Proposing water balance method for water availability estimation in Indonesian regional spatial planning

    NASA Astrophysics Data System (ADS)

    Juniati, A. T.; Sutjiningsih, D.; Soeryantono, H.; Kusratmoko, E.

    2018-01-01

    The water availability (WA) of a region is one of important consideration in both the formulation of spatial plans and the evaluation of the effectiveness of actual land use in providing sustainable water resources. Information on land-water needs vis-a-vis their availability in a region determines the state of the surplus or deficit to inform effective land use utilization. How to calculate water availability have been described in the Guideline in Determining the Carrying Capacity of the Environment in Regional Spatial Planning. However, the method of determining the supply and demand of water on these guidelines is debatable since the determination of WA in this guideline used a rational method. The rational method is developed the basis for storm drain design practice and it is essentially a peak discharge method peak discharge calculation method. This paper review the literature in methods of water availability estimation which is described descriptively, and present arguments to claim that water balance method is a more fundamental and appropriate tool in water availability estimation. A better water availability estimation method would serve to improve the practice in preparing formulations of Regional Spatial Plan (RSP) as well as evaluating land use capacity in providing sustainable water resources.

  1. L-Cysteine capped CdTe-CdS core-shell quantum dots: preparation, characterization and immuno-labeling of HeLa cells.

    PubMed

    Zhang, Hongyan; Sun, Pan; Liu, Chang; Gao, Huanyu; Xu, Linru; Fang, Jin; Wang, Meng; Liu, Jinling; Xu, Shukun

    2011-01-01

    Functionalized CdTe-CdS core-shell quantum dots (QDs) were synthesized in aqueous solution via water-bathing combined hydrothermal method using L-cysteine (L-Cys) as a stabilizer. This method possesses both the advantages of water-bathing and hydrothermal methods for preparing high-quality QDs with markedly reduced synthesis time, and better stability than a lone hydrothermal method. The QDs were characterized by transmission electronic microscopy and powder X-ray diffraction and X-ray photoelectron spectroscopy. The CdTe-CdS QDs with core-shell structure showed both enhanced fluorescence and better photo stability than nude CdTe QDs. After conjugating with antibody rabbit anti-CEACAM8 (CD67), the as-prepared l-Cys capped CdTe-CdS QDs were successfully used as fluorescent probes for the direct immuno-labeling and imaging of HeLa cells. It was indicated that this kind of QD would have application potential in bio-labeling and cell imaging. Copyright © 2009 John Wiley & Sons, Ltd.

  2. 7 CFR 60.300 - Labeling.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... AGRICULTURAL MARKETING ACT OF 1946 AND THE EGG PRODUCTS INSPECTION ACT (CONTINUED) COUNTRY OF ORIGIN LABELING FOR FISH AND SHELLFISH General Provisions Country of Origin Notification § 60.300 Labeling. (a) Country of origin declarations and method of production (wild and/or farm-raised) designations can either...

  3. 7 CFR 60.300 - Labeling.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... AGRICULTURAL MARKETING ACT OF 1946 AND THE EGG PRODUCTS INSPECTION ACT (CONTINUED) COUNTRY OF ORIGIN LABELING FOR FISH AND SHELLFISH General Provisions Country of Origin Notification § 60.300 Labeling. (a) Country of origin declarations and method of production (wild and/or farm-raised) designations can either...

  4. 7 CFR 60.300 - Labeling.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... AGRICULTURAL MARKETING ACT OF 1946 AND THE EGG PRODUCTS INSPECTION ACT (CONTINUED) COUNTRY OF ORIGIN LABELING FOR FISH AND SHELLFISH General Provisions Country of Origin Notification § 60.300 Labeling. (a) Country of origin declarations and method of production (wild and/or farm-raised) designations can either...

  5. 7 CFR 60.300 - Labeling.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... AGRICULTURAL MARKETING ACT OF 1946 AND THE EGG PRODUCTS INSPECTION ACT (CONTINUED) COUNTRY OF ORIGIN LABELING FOR FISH AND SHELLFISH General Provisions Country of Origin Notification § 60.300 Labeling. (a) Country of origin declarations and method of production (wild and/or farm-raised) designations can either...

  6. Interdisciplinary Methods in Water Resources

    ERIC Educational Resources Information Center

    Cosens, Barbara; Fiedler, Fritz; Boll, Jan; Higgins, Lorie; Johnson, Gary; Kennedy, Brian; Strand, Eva; Wilson, Patrick; Laflin, Maureen

    2011-01-01

    In the face of a myriad of complex water resource issues, traditional disciplinary separation is ineffective in developing approaches to promote a sustainable water future. As part of a new graduate program in water resources, faculty at the University of Idaho have developed a course on interdisciplinary methods designed to prepare students for…

  7. Label-Free Fluorescence Assay of S1 Nuclease and Hydroxyl Radicals Based on Water-Soluble Conjugated Polymers and WS₂ Nanosheets.

    PubMed

    Li, Junting; Zhao, Qi; Tang, Yanli

    2016-06-13

    We developed a new method for detecting S1 nuclease and hydroxyl radicals based on the use of water-soluble conjugated poly[9,9-bis(6,6-(N,N,N-trimethylammonium)-fluorene)-2,7-ylenevinylene-co-alt-2,5-dicyano-1,4-phenylene)] (PFVCN) and tungsten disulfide (WS₂) nanosheets. Cationic PFVCN is used as a signal reporter, and single-layer WS₂ is used as a quencher with a negatively charged surface. The ssDNA forms complexes with PFVCN due to much stronger electrostatic interactions between cationic PFVCN and anionic ssDNA, whereas PFVCN emits yellow fluorescence. When ssDNA is hydrolyzed by S1 nuclease or hydroxyl radicals into small fragments, the interactions between the fragmented DNA and PFVCN become weaker, resulting in PFVCN being adsorbed on the surface of WS₂ and the fluorescence being quenched through fluorescence resonance energy transfer. The new method based on PFVCN and WS₂ can sense S1 nuclease with a low detection limit of 5 × 10(-6) U/mL. Additionally, this method is cost-effective by using affordable WS₂ as an energy acceptor without the need for dye-labeled ssDNA. Furthermore, the method provides a new platform for the nuclease assay and reactive oxygen species, and provides promising applications for drug screening.

  8. A method for the analysis of perfluorinated compounds in environmental and drinking waters and the determination of their lowest concentration minimal reporting levels.

    PubMed

    Boone, J Scott; Guan, Bing; Vigo, Craig; Boone, Tripp; Byrne, Christian; Ferrario, Joseph

    2014-06-06

    A trace analytical method was developed for the determination of seventeen specific perfluorinated chemicals (PFCs) in environmental and drinking waters. The objectives were to optimize an isotope-dilution method to increase the precision and accuracy of the analysis of the PFCs and to eliminate the need for matrix-matched standards. A 250 mL sample of environmental or drinking water was buffered to a pH of 4, spiked with labeled surrogate standards, extracted through solid phase extraction cartridges, and eluted with ammonium hydroxide in methyl tert-butyl ether: methanol solution. The sample eluents were concentrated to volume and analyzed by liquid chromatography/tandem mass spectrometry (LC-MS/MS). The lowest concentration minimal reporting levels (LCMRLs) for the seventeen PFCs were calculated and ranged from 0.034 to 0.600 ng/L for surface water and from 0.033 to 0.640 ng/L for drinking water. The relative standard deviations (RSDs) for all compounds were <20% for all concentrations above the LCMRL. The method proved effective and cost efficient and addressed the problems with the recovery of perfluorobutanoic acid (PFBA) and other short chain PFCs. Various surface water and drinking water samples were used during method development to optimize this method. The method was used to evaluate samples from the Mississippi River at New Orleans and drinking water samples from a private residence in that same city. The method was also used to determine PFC contamination in well water samples from a fire training area where perfluorinated foams were used in training to extinguish fires. Published by Elsevier B.V.

  9. Method and apparatus for tritiated water separation

    DOEpatents

    Nelson, David A.; Duncan, James B.; Jensen, George A.

    1995-01-01

    The present invention is a membrane method and apparatus for separating isotopic water constituents from light water. The method involves providing a supported membrane of an aromatic polyphosphazene and pressurizing the water on one side of the membrane thereby forcing the light water through the supported membrane while isotopic water constituents are retained or vice versa. The apparatus of the present invention includes an aromatic polyphosphazene placed on a porous support and means for pressurizing water through the membrane while certain isotopic water constituents are retained.

  10. Method Development and Monitoring of Cyanotoxins in Water ...

    EPA Pesticide Factsheets

    Increasing occurrence of cyanobacterial harmful algal blooms (HABs) in ambient waters has become a worldwide concern. Numerous cyanotoxins can be produced during HAB events which are toxic to animals and humans. Validated standardized methods that are rugged, selective and sensitive are needed for these cyanotoxins in drinking and ambient waters. EPA Drinking Water Methods 544 (six microcystins [MCs] and nodularin) and 545 (cylindrospermopsin [CYL] and anatoxin-a [ANA]) have been developed using liquid chromatography/tandem mass spectrometry (LC/MS/MS). This presentation will describe the adaptation of Methods 544 and 545 to ambient waters and application of these ambient water methods to seven bodies of water across the country with visible cyanobacterial blooms.Several changes were made to Method 544 to accommodate the increased complexity of ambient water. The major changes were to reduce the sample volume from 500 to 100 mL for ambient water analyses and to incorporate seven additional MCs in an effort to capture data for more MC congeners in ambient waters. The major change to Method 545 for ambient water analyses was the addition of secondary ion transitions for each of the target analytes for confirmation purposes. Both methods have been ruggedly tested in bloom samples from multiple bodies of water, some with multiple sample locations and sampling days. For ambient water bloom samples spiked with MCs (>800 congener measurements), 97% of the measurements

  11. 16 CFR 305.16 - Labeling and marking for plumbing products.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... CONGRESS RULE CONCERNING DISCLOSURES REGARDING ENERGY CONSUMPTION AND WATER USE OF CERTAIN HOME APPLIANCES AND OTHER PRODUCTS REQUIRED UNDER THE ENERGY POLICY AND CONSERVATION ACT (âAPPLIANCE LABELING RULEâ... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Labeling and marking for plumbing products...

  12. 16 CFR 305.16 - Labeling and marking for plumbing products.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... CONGRESS RULE CONCERNING DISCLOSURES REGARDING ENERGY CONSUMPTION AND WATER USE OF CERTAIN HOME APPLIANCES AND OTHER PRODUCTS REQUIRED UNDER THE ENERGY POLICY AND CONSERVATION ACT (âAPPLIANCE LABELING RULEâ... 16 Commercial Practices 1 2013-01-01 2013-01-01 false Labeling and marking for plumbing products...

  13. 16 CFR 305.16 - Labeling and marking for plumbing products.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... CONGRESS RULE CONCERNING DISCLOSURES REGARDING ENERGY CONSUMPTION AND WATER USE OF CERTAIN HOME APPLIANCES AND OTHER PRODUCTS REQUIRED UNDER THE ENERGY POLICY AND CONSERVATION ACT (âAPPLIANCE LABELING RULEâ... 16 Commercial Practices 1 2012-01-01 2012-01-01 false Labeling and marking for plumbing products...

  14. Comprehensive assessment of impaired peripheral and coronary artery endothelial functions in smokers using brachial artery ultrasound and oxygen-15-labeled water PET.

    PubMed

    Ochi, Noriki; Yoshinaga, Keiichiro; Ito, Yoichi M; Tomiyama, Yuuki; Inoue, Mamiko; Nishida, Mutsumi; Manabe, Osamu; Shibuya, Hitoshi; Shimizu, Chikara; Suzuki, Eriko; Fujii, Satoshi; Katoh, Chietsugu; Tamaki, Nagara

    2016-10-01

    Comprehensive evaluation of endothelium-dependent and endothelium-independent vascular functions in peripheral arteries and coronary arteries in smokers has never been performed previously. Through the use of brachial artery ultrasound and oxygen-15-labeled water positron emission tomography (PET), we sought to investigate peripheral and coronary vascular dysfunctions in smokers. Eight smokers and 10 healthy individuals underwent brachial artery ultrasound at rest, during reactive hyperemia [250mmHg cuff occlusion (flow-mediated dilatation (FMD)], and following sublingual nitroglycerin (NTG) administration. Myocardial blood flow (MBF) was assessed through O-15-labeled water PET at rest, during adenosine triphosphate (ATP) administration, and during a cold pressor test (CPT). Through ultrasound, smokers were shown to have significantly reduced %FMD compared to controls (6.62±2.28% vs. 11.29±2.75%, p=0.0014). As assessed by O-15-labeled water PET, smokers were shown to have a significantly lower CPT response than were controls (21.1±9.5% vs. 50.9±16.9%, p=0.0004). There was no relationship between %FMD and CPT response (r=0.40, p=0.097). Endothelium-independent vascular dilatation was similar for both groups in terms of coronary flow reserve with PET (p=0.19). Smokers tended to have lower %NTG in the brachial artery (p=0.055). Smokers exhibited impaired coronary endothelial function as well as peripheral brachial artery endothelial function. In addition, there was no correlation between PET and ultrasound measurements, possibly implying that while smokers may have systemic vascular endothelial dysfunction, the characteristics of that dysfunction may be different in peripheral arteries and coronary arteries. Copyright © 2016. Published by Elsevier Ltd.

  15. Method and apparatus for tritiated water separation

    DOEpatents

    Nelson, D.A.; Duncan, J.B.; Jensen, G.A.

    1995-09-19

    The present invention is a membrane method and apparatus for separating isotopic water constituents from light water. The method involves providing a supported membrane of an aromatic polyphosphazene and pressurizing the water on one side of the membrane thereby forcing the light water through the supported membrane while isotopic water constituents are retained or vice versa. The apparatus of the present invention includes an aromatic polyphosphazene placed on a porous support and means for pressurizing water through the membrane while certain isotopic water constituents are retained. 1 fig.

  16. Fast methodology for the reliable determination of nonylphenol in water samples by minimal labeling isotope dilution mass spectrometry.

    PubMed

    Fabregat-Cabello, Neus; Castillo, Ángel; Sancho, Juan V; González, Florenci V; Roig-Navarro, Antoni Francesc

    2013-08-02

    In this work we have developed and validated an accurate and fast methodology for the determination of 4-nonylphenol (technical mixture) in complex matrix water samples by UHPLC-ESI-MS/MS. The procedure is based on isotope dilution mass spectrometry (IDMS) in combination with isotope pattern deconvolution (IPD), which provides the concentration of the analyte directly from the spiked sample without requiring any methodological calibration graph. To avoid any possible isotopic effect during the analytical procedure the in-house synthesized (13)C1-4-(3,6-dimethyl-3-heptyl)phenol was used as labeled compound. This proposed surrogate was able to compensate the matrix effect even from wastewater samples. A SPE pre-concentration step together with exhaustive efforts to avoid contamination were included to reach the signal-to-noise ratio necessary to detect the endogenous concentrations present in environmental samples. Calculations were performed acquiring only three transitions, achieving limits of detection lower than 100ng/g for all water matrix assayed. Recoveries within 83-108% and coefficients of variation ranging from 1.5% to 9% were obtained. On the contrary a considerable overestimation was obtained with the most usual classical calibration procedure using 4-n-nonylphenol as internal standard, demonstrating the suitability of the minimal labeling approach. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. In vivo labeling and specific magnetic bead separation of RNA for biofilm characterization and stress-induced gene expression analysis in bacteria.

    PubMed

    Stankiewicz, Nikolai; Gold, Andrea; Yüksel, Yousra; Berensmeier, Sonja; Schwartz, Thomas

    2009-12-01

    The method of in vivo labeling and separation of bacterial RNA was developed as an approach to elucidating the stress response of natural bacterial populations. This technique is based on the incorporation of digoxigenin-11-uridine-5'-triphosphate (DIG-11-UTP) in the RNA of active bacteria. The digoxigenin fulfills a dual role as a label of de novo synthesized RNA and a target for magnetic bead separation from a total RNA extract. Depending on the growth conditions and the population's composition, the assembly rate of DIG-11-UTP ranged from 1.2% to 12.5% of the total RNA in gram-positive and gram-negative reference bacteria as well as in natural biofilms from drinking water, surface water, and lake sediment. Separation of DIG-RNA from total RNA extracts was performed with a biotinylated anti-digoxigenin antibody and streptavidin-functionalized magnetic particles. The average separation yield from total RNA extracts was about 95% of labeled RNA. The unspecific bindings of non-labeled nucleic acids were smaller than 0.2%, as was evaluated by spiking experiments with an unmarked DNA amplicon. Applicability of the method developed was demonstrated by rRNA-directed PCR-DGGE population analysis of natural biofilms and expression profiling of two stress-induced genes (vanA and rpoS) in reference bacteria.

  18. PRN 93-10: Effluent Discharge Labeling Statements

    EPA Pesticide Factsheets

    This notice describes revised effluent discharge labeling statements required on all manufacturing use products and end use products that may be discharged to waters of the United States ormunicipal sewer systems.

  19. Dual-labeling method for electron microscopy to characterize synaptic connectivity using genetically encoded fluorescent reporters in Drosophila

    PubMed Central

    Tanaka, Nobuaki K.; Dye, Louis; Stopfer, Mark

    2010-01-01

    Light and electron microscopy (LM and EM) both offer important advantages for characterizing neuronal circuitry in intact brains: LM can reveal the general patterns neurons trace between brain areas, and EM can confirm synaptic connections between identified neurons within a small area. In a few species, genetic labeling with fluorescent proteins has been used with LM to visualize many kinds of neurons and to analyze their morphologies and projection patterns. However, combining these large-scale patterns with the fine detail available in EM analysis has been a technical challenge. To analyze the synaptic connectivity of neurons expressing fluorescent markers with EM, we developed a dual-labeling method for use with pre-embedded brains. In Drosophila expressing genetic labels and also injected with markers we visualized synaptic connections among two populations of neurons in the AL, one of which has been shown to mediate a specific function, odor evoked neural oscillation. PMID:21074556

  20. Tritium ( 3 H) Retention In Mice: Administered As HTO, DTO or as 3 H-Labeled Amino-Acids.

    PubMed

    Priest, Nicholas D; Blimkie, Melinda S J; Wyatt, Heather; Bugden, Michelle; Bannister, Laura A; Gueguen, Yann; Jourdain, Jean-Rene; Klokov, Dmitry

    2017-05-01

    The objective of this study was to compare the biokinetics of injected H-labeled light (HTO) and heavy (DTO) water in CBA/CaJ mice and to compare the organ distribution and/or body content of H administered by chronic ingestion for 1 mo to C57Bl/6J mice, as either H-labeled water or H-labeled amino acids (glycine, alanine and proline). HTO and DTO were administered to CBA/CaJ mice by single intraperitoneal injection and body retention was determined for up to 384 h post-injection. Tritium-labeled water or H-labeled amino acids were given to C57Bl/6J mice ad libitum for 30 d in drinking water. Body content and organ distribution of H during the period of administration and subsequent to administration was determined by liquid scintillation counting. No differences were found between the biokinetics of HTO and DTO, indicating that data generated using HTO can be used to help assess the consequences of H releases from heavy water reactors. The results for H-water showed that the concentration of radionuclide in the mice reached a peak after about 10 d and dropped rapidly after the cessation of H administration. The maximum concentration reached was only 50% of that in the water consumed, indicating that mice receive a significant fraction of their water from respiration. Contrary to the findings of others, the pattern of H retention following the administration of a cocktail of the labeled amino acids was very little different from that found for the water. This is consistent with the suggestion that most of the ingested amino acids were rapidly metabolized, releasing water and carbon dioxide.

  1. Protein C-Terminal Labeling and Biotinylation Using Synthetic Peptide and Split-Intein

    PubMed Central

    Volkmann, Gerrit; Liu, Xiang-Qin

    2009-01-01

    Background Site-specific protein labeling or modification can facilitate the characterization of proteins with respect to their structure, folding, and interaction with other proteins. However, current methods of site-specific protein labeling are few and with limitations, therefore new methods are needed to satisfy the increasing need and sophistications of protein labeling. Methodology A method of protein C-terminal labeling was developed using a non-canonical split-intein, through an intein-catalyzed trans-splicing reaction between a protein and a small synthetic peptide carrying the desired labeling groups. As demonstrations of this method, three different proteins were efficiently labeled at their C-termini with two different labels (fluorescein and biotin) either in solution or on a solid surface, and a transferrin receptor protein was labeled on the membrane surface of live mammalian cells. Protein biotinylation and immobilization on a streptavidin-coated surface were also achieved in a cell lysate without prior purification of the target protein. Conclusions We have produced a method of site-specific labeling or modification at the C-termini of recombinant proteins. This method compares favorably with previous protein labeling methods and has several unique advantages. It is expected to have many potential applications in protein engineering and research, which include fluorescent labeling for monitoring protein folding, location, and trafficking in cells, and biotinylation for protein immobilization on streptavidin-coated surfaces including protein microchips. The types of chemical labeling may be limited only by the ability of chemical synthesis to produce the small C-intein peptide containing the desired chemical groups. PMID:20027230

  2. The legibility of prescription medication labelling in Canada

    PubMed Central

    Ahrens, Kristina; Krishnamoorthy, Abinaya; Gold, Deborah; Rojas-Fernandez, Carlos H.

    2014-01-01

    Introduction: The legibility of medication labelling is a concern for all Canadians, because poor or illegible labelling may lead to miscommunication of medication information and poor patient outcomes. There are currently few guidelines and no regulations regarding print standards on medication labels. This study analyzed sample prescription labels from Ontario, Canada, and compared them with print legibility guidelines (both generic and specific to medication labels). Methods: Cluster sampling was used to randomly select a total of 45 pharmacies in the tri-cities of Kitchener, Waterloo and Cambridge. Pharmacies were asked to supply a regular label with a hypothetical prescription. The print characteristics of patient-critical information were compared against the recommendations for prescription labels by pharmaceutical and health organizations and for print accessibility by nongovernmental organizations. Results: More than 90% of labels followed the guidelines for font style, contrast, print colour and nonglossy paper. However, only 44% of the medication instructions met the minimum guideline of 12-point print size, and none of the drug or patient names met this standard. Only 5% of the labels were judged to make the best use of space, and 51% used left alignment. None of the instructions were in sentence case, as is recommended. Discussion: We found discrepancies between guidelines and current labels in print size, justification, spacing and methods of emphasis. Conclusion: Improvements in pharmacy labelling are possible without moving to new technologies or changing the size of labels and would be expected to enhance patient outcomes. PMID:24847371

  3. 33 CFR 159.16 - Authorization to label devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....S. Coast Guard pursuant to section 312 of the Federal Water Pollution Control Act Amendments of 1972... required by section 312(h)(4) of the Federal Water Pollution Control Act Amendments of 1972, which makes it... (CONTINUED) POLLUTION MARINE SANITATION DEVICES Certification Procedures § 159.16 Authorization to label...

  4. Label Information Guided Graph Construction for Semi-Supervised Learning.

    PubMed

    Zhuang, Liansheng; Zhou, Zihan; Gao, Shenghua; Yin, Jingwen; Lin, Zhouchen; Ma, Yi

    2017-09-01

    In the literature, most existing graph-based semi-supervised learning methods only use the label information of observed samples in the label propagation stage, while ignoring such valuable information when learning the graph. In this paper, we argue that it is beneficial to consider the label information in the graph learning stage. Specifically, by enforcing the weight of edges between labeled samples of different classes to be zero, we explicitly incorporate the label information into the state-of-the-art graph learning methods, such as the low-rank representation (LRR), and propose a novel semi-supervised graph learning method called semi-supervised low-rank representation. This results in a convex optimization problem with linear constraints, which can be solved by the linearized alternating direction method. Though we take LRR as an example, our proposed method is in fact very general and can be applied to any self-representation graph learning methods. Experiment results on both synthetic and real data sets demonstrate that the proposed graph learning method can better capture the global geometric structure of the data, and therefore is more effective for semi-supervised learning tasks.

  5. A Coding Method for Efficient Subgraph Querying on Vertex- and Edge-Labeled Graphs

    PubMed Central

    Zhu, Lei; Song, Qinbao; Guo, Yuchen; Du, Lei; Zhu, Xiaoyan; Wang, Guangtao

    2014-01-01

    Labeled graphs are widely used to model complex data in many domains, so subgraph querying has been attracting more and more attention from researchers around the world. Unfortunately, subgraph querying is very time consuming since it involves subgraph isomorphism testing that is known to be an NP-complete problem. In this paper, we propose a novel coding method for subgraph querying that is based on Laplacian spectrum and the number of walks. Our method follows the filtering-and-verification framework and works well on graph databases with frequent updates. We also propose novel two-step filtering conditions that can filter out most false positives and prove that the two-step filtering conditions satisfy the no-false-negative requirement (no dismissal in answers). Extensive experiments on both real and synthetic graphs show that, compared with six existing counterpart methods, our method can effectively improve the efficiency of subgraph querying. PMID:24853266

  6. A transversal approach for patch-based label fusion via matrix completion

    PubMed Central

    Sanroma, Gerard; Wu, Guorong; Gao, Yaozong; Thung, Kim-Han; Guo, Yanrong; Shen, Dinggang

    2015-01-01

    Recently, multi-atlas patch-based label fusion has received an increasing interest in the medical image segmentation field. After warping the anatomical labels from the atlas images to the target image by registration, label fusion is the key step to determine the latent label for each target image point. Two popular types of patch-based label fusion approaches are (1) reconstruction-based approaches that compute the target labels as a weighted average of atlas labels, where the weights are derived by reconstructing the target image patch using the atlas image patches; and (2) classification-based approaches that determine the target label as a mapping of the target image patch, where the mapping function is often learned using the atlas image patches and their corresponding labels. Both approaches have their advantages and limitations. In this paper, we propose a novel patch-based label fusion method to combine the above two types of approaches via matrix completion (and hence, we call it transversal). As we will show, our method overcomes the individual limitations of both reconstruction-based and classification-based approaches. Since the labeling confidences may vary across the target image points, we further propose a sequential labeling framework that first labels the highly confident points and then gradually labels more challenging points in an iterative manner, guided by the label information determined in the previous iterations. We demonstrate the performance of our novel label fusion method in segmenting the hippocampus in the ADNI dataset, subcortical and limbic structures in the LONI dataset, and mid-brain structures in the SATA dataset. We achieve more accurate segmentation results than both reconstruction-based and classification-based approaches. Our label fusion method is also ranked 1st in the online SATA Multi-Atlas Segmentation Challenge. PMID:26160394

  7. Spin-Label Oximetry at Q- and W-Band

    PubMed Central

    Subczynski, W.K.; Mainali, L.; Camenisch, T.G.; Froncisz, W.; Hyde, J.S.

    2011-01-01

    Spin-lattice relaxation times (T1s) of both small water-soluble spin labels in the aqueous phase as well as lipid-type spin labels in membranes increase when the microwave frequency increases from 2 to 35 GHz (Hyde et al., J. Phys. Chem. B 108 [2004] 9524–9529). The T1 measured at W-band (94 GHz) for the water-soluble spin labels CTPO and TEMPONE (Froncisz et al., J. Magn. Reson. 193 [2008] 297–304) is, however, shorter than when measured at Q-band (35 GHz). In this paper, the decreasing trends at W-band have been confirmed for commonly used lipid-type spin labels in model membranes. It is concluded that the longest values of T1 will generally be found at Q-band, noting that long values are advantageous for measurement of bimolecular collisions with oxygen. The contribution of dissolved molecular oxygen to the relaxation rate was found to be independent of microwave frequency up to 94 GHz for lipid-type spin labels in membranes. This contribution is expressed in terms of the oxygen transport parameter W = T1−1(Air) − T1−1(N2), which is a function of both concentration and translational diffusion of oxygen in the local environment of a spin label. The new capabilities in measurement of the oxygen transport parameter using saturation-recovery (SR) EPR at Q- and W-band have been demonstrated in saturated (DMPC) and unsaturated (POPC) lipid bilayer membranes with the use of stearic acid (n-SASL) and phosphatidylcholine (n-PC) spin labels, and compared with results obtained earlier at X-band. SR EPR spin-label oximetry at Q- and W-band has the potential to be a powerful tool for studying samples of small volume, ~30 nL. These benefits, together with other factors such as a higher resonator efficiency parameter and a new technique for canceling free induction decay signals, are discussed. PMID:21277814

  8. Progressive Label Fusion Framework for Multi-atlas Segmentation by Dictionary Evolution

    PubMed Central

    Song, Yantao; Wu, Guorong; Sun, Quansen; Bahrami, Khosro; Li, Chunming; Shen, Dinggang

    2015-01-01

    Accurate segmentation of anatomical structures in medical images is very important in neuroscience studies. Recently, multi-atlas patch-based label fusion methods have achieved many successes, which generally represent each target patch from an atlas patch dictionary in the image domain and then predict the latent label by directly applying the estimated representation coefficients in the label domain. However, due to the large gap between these two domains, the estimated representation coefficients in the image domain may not stay optimal for the label fusion. To overcome this dilemma, we propose a novel label fusion framework to make the weighting coefficients eventually to be optimal for the label fusion by progressively constructing a dynamic dictionary in a layer-by-layer manner, where a sequence of intermediate patch dictionaries gradually encode the transition from the patch representation coefficients in image domain to the optimal weights for label fusion. Our proposed framework is general to augment the label fusion performance of the current state-of-the-art methods. In our experiments, we apply our proposed method to hippocampus segmentation on ADNI dataset and achieve more accurate labeling results, compared to the counterpart methods with single-layer dictionary. PMID:26942233

  9. Progressive Label Fusion Framework for Multi-atlas Segmentation by Dictionary Evolution.

    PubMed

    Song, Yantao; Wu, Guorong; Sun, Quansen; Bahrami, Khosro; Li, Chunming; Shen, Dinggang

    2015-10-01

    Accurate segmentation of anatomical structures in medical images is very important in neuroscience studies. Recently, multi-atlas patch-based label fusion methods have achieved many successes, which generally represent each target patch from an atlas patch dictionary in the image domain and then predict the latent label by directly applying the estimated representation coefficients in the label domain. However, due to the large gap between these two domains, the estimated representation coefficients in the image domain may not stay optimal for the label fusion. To overcome this dilemma, we propose a novel label fusion framework to make the weighting coefficients eventually to be optimal for the label fusion by progressively constructing a dynamic dictionary in a layer-by-layer manner, where a sequence of intermediate patch dictionaries gradually encode the transition from the patch representation coefficients in image domain to the optimal weights for label fusion. Our proposed framework is general to augment the label fusion performance of the current state-of-the-art methods. In our experiments, we apply our proposed method to hippocampus segmentation on ADNI dataset and achieve more accurate labeling results, compared to the counterpart methods with single-layer dictionary.

  10. Anterograde Tracing Method using DiI to Label Vagal Innervation of the Embryonic and Early Postnatal Mouse Gastrointestinal Tract

    PubMed Central

    Murphy, Michelle C.; Fox, Edward A.

    2007-01-01

    The mouse is an extremely valuable model for studying vagal development in relation to strain differences, genetic variation, gene manipulations, or pharmacological manipulations. Therefore, a method using 1, 1′-dioctadecyl-3,3,3′,3′-tetramethylindocarbocyanine perchlorate (DiI) was developed for labeling vagal innervation of the gastrointestinal (GI) tract in embryonic and postnatal mice. DiI labeling was adapted and optimized for this purpose by varying several facets of the method. For example, insertion and crushing of DiI crystals into the nerve led to faster DiI diffusion along vagal axons and diffusion over longer distances as compared with piercing the nerve with a micropipette tip coated with dried DiI oil. Moreover, inclusion of EDTA in the fixative reduced leakage of DiI out of nerve fibers that occurred with long incubations. Also, mounting labeled tissue in PBS was superior to glycerol with n-propyl gallate, which resulted in reduced clarity of DiI labeling that may have been due to DiI leaking out of fibers. Optical sectioning of flattened wholemounts permitted examination of individual tissue layers of the GI tract wall. This procedure aided identification of nerve ending types because in most instances each type innervates a different tissue layer. Between embryonic day 12.5 and postnatal day 8, growth of axons into the GI tract, formation and patterning of fiber bundles in the myenteric plexus and early formation of putative afferent and efferent nerve terminals were observed. Thus, the DiI tracing method developed here has opened up a window for investigation during an important phase of vagal development. PMID:17418900

  11. A new automated NaCl based robust method for routine production of gallium-68 labeled peptides

    PubMed Central

    Schultz, Michael K.; Mueller, Dirk; Baum, Richard P.; Watkins, G. Leonard; Breeman, Wouter A. P.

    2017-01-01

    A new NaCl based method for preparation of gallium-68 labeled radiopharmaceuticals has been adapted for use with an automated gallium-68 generator system. The method was evaluated based on 56 preparations of [68Ga]DOTATOC and compared to a similar acetone-based approach. Advantages of the new NaCl approach include reduced preparation time (< 15 min) and removal of organic solvents. The method produces high peptide-bound % (> 97%), and specific activity (> 40 MBq nmole−1 [68Ga]DOTATOC) and is well-suited for clinical production of radiopharmaceuticals. PMID:23026223

  12. Label-free functional nucleic acid sensors for detecting target agents

    DOEpatents

    Lu, Yi; Xiang, Yu

    2015-01-13

    A general methodology to design label-free fluorescent functional nucleic acid sensors using a vacant site approach and an abasic site approach is described. In one example, a method for designing label-free fluorescent functional nucleic acid sensors (e.g., those that include a DNAzyme, aptamer or aptazyme) that have a tunable dynamic range through the introduction of an abasic site (e.g., dSpacer) or a vacant site into the functional nucleic acids. Also provided is a general method for designing label-free fluorescent aptamer sensors based on the regulation of malachite green (MG) fluorescence. A general method for designing label-free fluorescent catalytic and molecular beacons (CAMBs) is also provided. The methods demonstrated here can be used to design many other label-free fluorescent sensors to detect a wide range of analytes. Sensors and methods of using the disclosed sensors are also provided.

  13. Development of high-performance chemical isotope labeling LC-MS for profiling the human fecal metabolome.

    PubMed

    Xu, Wei; Chen, Deying; Wang, Nan; Zhang, Ting; Zhou, Ruokun; Huan, Tao; Lu, Yingfeng; Su, Xiaoling; Xie, Qing; Li, Liang; Li, Lanjuan

    2015-01-20

    Human fecal samples contain endogenous human metabolites, gut microbiota metabolites, and other compounds. Profiling the fecal metabolome can produce metabolic information that may be used not only for disease biomarker discovery, but also for providing an insight about the relationship of the gut microbiome and human health. In this work, we report a chemical isotope labeling liquid chromatography-mass spectrometry (LC-MS) method for comprehensive and quantitative analysis of the amine- and phenol-containing metabolites in fecal samples. Differential (13)C2/(12)C2-dansyl labeling of the amines and phenols was used to improve LC separation efficiency and MS detection sensitivity. Water, methanol, and acetonitrile were examined as an extraction solvent, and a sequential water-acetonitrile extraction method was found to be optimal. A step-gradient LC-UV setup and a fast LC-MS method were evaluated for measuring the total concentration of dansyl labeled metabolites that could be used for normalizing the sample amounts of individual samples for quantitative metabolomics. Knowing the total concentration was also useful for optimizing the sample injection amount into LC-MS to maximize the number of metabolites detectable while avoiding sample overloading. For the first time, dansylation isotope labeling LC-MS was performed in a simple time-of-flight mass spectrometer, instead of high-end equipment, demonstrating the feasibility of using a low-cost instrument for chemical isotope labeling metabolomics. The developed method was applied for profiling the amine/phenol submetabolome of fecal samples collected from three families. An average of 1785 peak pairs or putative metabolites were found from a 30 min LC-MS run. From 243 LC-MS runs of all the fecal samples, a total of 6200 peak pairs were detected. Among them, 67 could be positively identified based on the mass and retention time match to a dansyl standard library, while 581 and 3197 peak pairs could be putatively

  14. Comparison of electrical conductivity calculation methods for natural waters

    USGS Publications Warehouse

    McCleskey, R. Blaine; Nordstrom, D. Kirk; Ryan, Joseph N.

    2012-01-01

    The capability of eleven methods to calculate the electrical conductivity of a wide range of natural waters from their chemical composition was investigated. A brief summary of each method is presented including equations to calculate the conductivities of individual ions, the ions incorporated, and the method's limitations. The ability of each method to reliably predict the conductivity depends on the ions included, effective accounting of ion pairing, and the accuracy of the equation used to estimate the ionic conductivities. The performances of the methods were evaluated by calculating the conductivity of 33 environmentally important electrolyte solutions, 41 U.S. Geological Survey standard reference water samples, and 1593 natural water samples. The natural waters tested include acid mine waters, geothermal waters, seawater, dilute mountain waters, and river water impacted by municipal waste water. The three most recent conductivity methods predict the conductivity of natural waters better than other methods. Two of the recent methods can be used to reliably calculate the conductivity for samples with pH values greater than about 3 and temperatures between 0 and 40°C. One method is applicable to a variety of natural water types with a range of pH from 1 to 10, temperature from 0 to 95°C, and ionic strength up to 1 m.

  15. Method Development and Monitoring of Cyanotoxins in Water ...

    EPA Pesticide Factsheets

    This presentation describes method development of two ambient water LC/MS/MS methods for microcystins, cylindrospermopsin and anatoxin-a. Ruggedness of the methods will be demonstrated by evaluation of quality control samples derived from various water bodies across the country. Presentation at the Central Regional meeting of the American Chemical Society ambient water methods development for cyanotoxins

  16. Points of Convergence in Music Education: The Use of Data Labels as a Strategy for Mixed Methods Integration

    ERIC Educational Resources Information Center

    Fitzpatrick, Kate R.

    2016-01-01

    Although the mixing of quantitative and qualitative data is an essential component of mixed methods research, the process of integrating both types of data in meaningful ways can be challenging. The purpose of this article is to describe the use of data labels in mixed methods research as a technique for the integration of qualitative and…

  17. Stable isotope dimethyl labelling for quantitative proteomics and beyond

    PubMed Central

    Hsu, Jue-Liang; Chen, Shu-Hui

    2016-01-01

    Stable-isotope reductive dimethylation, a cost-effective, simple, robust, reliable and easy-to- multiplex labelling method, is widely applied to quantitative proteomics using liquid chromatography-mass spectrometry. This review focuses on biological applications of stable-isotope dimethyl labelling for a large-scale comparative analysis of protein expression and post-translational modifications based on its unique properties of the labelling chemistry. Some other applications of the labelling method for sample preparation and mass spectrometry-based protein identification and characterization are also summarized. This article is part of the themed issue ‘Quantitative mass spectrometry’. PMID:27644970

  18. Imaging of endogenous exchangeable proton signals in the human brain using frequency labeled exchange transfer imaging.

    PubMed

    Yadav, Nirbhay N; Jones, Craig K; Hua, Jun; Xu, Jiadi; van Zijl, Peter C M

    2013-04-01

    To image endogenous exchangeable proton signals in the human brain using a recently reported method called frequency labeled exchange transfer (FLEX) MRI. As opposed to labeling exchangeable protons using saturation (i.e., chemical exchange saturation transfer, or CEST), FLEX labels exchangeable protons with their chemical shift evolution. The use of short high-power frequency pulses allows more efficient labeling of rapidly exchanging protons, while time domain acquisition allows removal of contamination from semi-solid magnetization transfer effects. FLEX-based exchangeable proton signals were detected in human brain over the 1-5 ppm frequency range from water. Conventional magnetization transfer contrast and the bulk water signal did not interfere in the FLEX spectrum. The information content of these signals differed from in vivo CEST data in that the average exchange rate of these signals was 350-400 s(-1) , much faster than the amide signal usually detected using direct saturation (∼30 s(-1) ). Similarly, fast exchanging protons could be detected in egg white in the same frequency range where amide and amine protons of mobile proteins and peptides are known to resonate. FLEX MRI in the human brain preferentially detects more rapidly exchanging amide/amine protons compared to traditional CEST experiments, thereby changing the information content of the exchangeable proton spectrum. This has the potential to open up different types of endogenous applications as well as more easy detection of rapidly exchanging protons in diaCEST agents or fast exchanging units such as water molecules in paracest agents without interference of conventional magnetization transfer contrast. Copyright © 2013 Wiley Periodicals, Inc.

  19. In situ measured elimination of Vibrio cholerae from brackish water.

    PubMed

    Pérez, María Elena Martínez; Macek, Miroslav; Galván, María Teresa Castro

    2004-01-01

    In situ elimination of fluorescently labelled Vibrio cholerae (FLB) was measured in two saline water bodies in Mexico: in a brackish water lagoon, Mecoacán (Gulf of Mexico; State of Tabasco) and an athalassohaline lake, Alchichica (State of Puebla). Disappearance rates of fluorescently labelled V. cholera O1 showed that they were eliminated from the environment at an average rate of 32% and 63%/day, respectively (based on the bacterial standing stocks). The indirect immunofluorescence method confirmed the presence of V. cholerae O1 in the lagoon. However, the elimination of FLB was not directly related either to the presence or absence of the bacterium in the water body or to the phytoplankton concentration.

  20. Analysis of IAV Replication and Co-infection Dynamics by a Versatile RNA Viral Genome Labeling Method.

    PubMed

    Dou, Dan; Hernández-Neuta, Iván; Wang, Hao; Östbye, Henrik; Qian, Xiaoyan; Thiele, Swantje; Resa-Infante, Patricia; Kouassi, Nancy Mounogou; Sender, Vicky; Hentrich, Karina; Mellroth, Peter; Henriques-Normark, Birgitta; Gabriel, Gülsah; Nilsson, Mats; Daniels, Robert

    2017-07-05

    Genome delivery to the proper cellular compartment for transcription and replication is a primary goal of viruses. However, methods for analyzing viral genome localization and differentiating genomes with high identity are lacking, making it difficult to investigate entry-related processes and co-examine heterogeneous RNA viral populations. Here, we present an RNA labeling approach for single-cell analysis of RNA viral replication and co-infection dynamics in situ, which uses the versatility of padlock probes. We applied this method to identify influenza A virus (IAV) infections in cells and lung tissue with single-nucleotide specificity and to classify entry and replication stages by gene segment localization. Extending the classification strategy to co-infections of IAVs with single-nucleotide variations, we found that the dependence on intracellular trafficking places a time restriction on secondary co-infections necessary for genome reassortment. Altogether, these data demonstrate how RNA viral genome labeling can help dissect entry and co-infections. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  1. Synthesis of a Potent Aminopyridine-Based nNOS-Inhibitor by Two Recent No-Carrier-Added (18)F-Labelling Methods.

    PubMed

    Drerup, Christian; Ermert, Johannes; Coenen, Heinz H

    2016-09-01

    Nitric oxide (NO), an important multifunctional signaling molecule, is produced by three isoforms of NO-synthase (NOS) and has been associated with neurodegenerative disorders. Selective inhibitors of the subtypes iNOS (inducible) or nNOS (neuronal) are of great interest for decoding neurodestructive key factors, and (18)F-labelled analogues would allow investigating the NOS-function by molecular imaging with positron emission tomography. Especially, the highly selective nNOS inhibitor 6-((3-((3-fluorophenethylamino)methyl)phenoxy)methyl)-4-methylpyridin-2-amine (10) lends itself as suitable compound to be (18)F-labelled in no-carrier-added (n.c.a.) form. For preparation of the (18)F-labelled nNOS-Inhibitor [(18)F]10 a "build-up" radiosynthesis was developed based on a corresponding iodonium ylide as labelling precursor. The such activated phenethyl group of the compound was efficiently and regioselectively labelled with n.c.a. [(18)F]fluoride in 79% radiochemical yield (RCY). After conversion by reductive amination and microwave assisted displacement of the protecting groups, the desired nNOS-inhibitor was obtained in about 15% total RCY. Alternatively, for a simplified "late-stage" (18)F-labelling procedure a corresponding boronic ester precursor was synthesized and successfully used in a newer, copper(II) mediated n.c.a. (18)F-fluoro-deboroniation reaction, achieving the same total RCY. Thus, both methods proved comparatively suited to provide the highly selective NOS-inhibitor [(18)F]10 as probe for preclinical in vivo studies.

  2. Use of Doubly Labeled Water to Validate a Physical Activity Questionnaire Developed for the Japanese Population

    PubMed Central

    Ishikawa-Takata, Kazuko; Naito, Yoshihiko; Tanaka, Shigeho; Ebine, Naoyuki; Tabata, Izumi

    2011-01-01

    Background No study has attempted to use the doubly labeled water (DLW) method to validate a physical activity questionnaire administered to a Japanese population. The development and refinement of such questionnaires require that physical activity components related to physical activity level be examined. Methods Among 226 Japanese men and women 20 to 83 years of age, total energy expenditure (TEE) was assessed using the Japan Arteriosclerosis Longitudinal Study Physical Activity Questionnaire (JALSPAQ), and the results were compared with TEE measured by the DLW method as a gold standard. Resting metabolic rate (RMR) was measured using the Douglas Bag method. Results The median TEE by DLW and physical activity level (PAL: TEE/RMR) were 11.21 MJ/day and 1.88, respectively, for men, and 8.42 MJ/day and 1.83 for women. JALSPAQ slightly underestimated TEE: the differences in mean and standard error were −1.15 ± 1.92 MJ/day. JALSPAQ and DLW TEE values were moderately correlated (Spearman correlation = 0.742, P < 0.001; intraclass correlation coefficient = 0.648, P < 0.001), and the 95% limit of agreement was −4.99 to 2.69 MJ. Underestimation of TEE by JALSPAQ was greater in active subjects than in less active subjects. Moderate and vigorous physical activity and physical activity during work (ie, occupational tasks and housework) were strongly related to physical activity level. However, the physical activity components that differentiated sedentary from moderately active subjects were not clear. Conclusions Physical activity level values on JALSPAQ and DLW were weakly correlated. In addition, estimation of TEE in active subjects should be improved, and the use of a questionnaire to differentiate activity in sedentary and moderately active subjects must be reassessed. PMID:21258166

  3. Predicting free-living energy expenditure using a miniaturized ear-worn sensor: an evaluation against doubly labeled water.

    PubMed

    Bouarfa, Loubna; Atallah, Louis; Kwasnicki, Richard Mark; Pettitt, Claire; Frost, Gary; Yang, Guang-Zhong

    2014-02-01

    Accurate estimation of daily total energy expenditure (EE)is a prerequisite for assisted weight management and assessing certain health conditions. The use of wearable sensors for predicting free-living EE is challenged by consistent sensor placement, user compliance, and estimation methods used. This paper examines whether a single ear-worn accelerometer can be used for EE estimation under free-living conditions.An EE prediction model as first derived and validated in a controlled setting using healthy subjects involving different physical activities. Ten different activities were assessed showing a tenfold cross validation error of 0.24. Furthermore, the EE prediction model shows a mean absolute deviation(MAD) below 1.2 metabolic equivalent of tasks. The same model was applied to a free-living setting with a different population for further validation. The results were compared against those derived from doubly labeled water. In free-living settings, the predicted daily EE has a correlation of 0.74, p 0.008, and a MAD of 272 kcal day. These results demonstrate that laboratory-derived prediction models can be used to predict EE under free-living conditions [corrected].

  4. A Quick and Parallel Analytical Method Based on Quantum Dots Labeling for ToRCH-Related Antibodies

    NASA Astrophysics Data System (ADS)

    Yang, Hao; Guo, Qing; He, Rong; Li, Ding; Zhang, Xueqing; Bao, Chenchen; Hu, Hengyao; Cui, Daxiang

    2009-12-01

    Quantum dot is a special kind of nanomaterial composed of periodic groups of II-VI, III-V or IV-VI materials. Their high quantum yield, broad absorption with narrow photoluminescence spectra and high resistance to photobleaching, make them become a promising labeling substance in biological analysis. Here, we report a quick and parallel analytical method based on quantum dots for ToRCH-related antibodies including Toxoplasma gondii, Rubella virus, Cytomegalovirus and Herpes simplex virus type 1 (HSV1) and 2 (HSV2). Firstly, we fabricated the microarrays with the five kinds of ToRCH-related antigens and used CdTe quantum dots to label secondary antibody and then analyzed 100 specimens of randomly selected clinical sera from obstetric outpatients. The currently prevalent enzyme-linked immunosorbent assay (ELISA) kits were considered as “golden standard” for comparison. The results show that the quantum dots labeling-based ToRCH microarrays have comparable sensitivity and specificity with ELISA. Besides, the microarrays hold distinct advantages over ELISA test format in detection time, cost, operation and signal stability. Validated by the clinical assay, our quantum dots-based ToRCH microarrays have great potential in the detection of ToRCH-related pathogens.

  5. Assessing of distribution, mobility and bioavailability of exogenous Pb in agricultural soils using isotopic labeling method coupled with BCR approach.

    PubMed

    Huang, Zhi-Yong; Xie, Hong; Cao, Ying-Lan; Cai, Chao; Zhang, Zhi

    2014-02-15

    The contamination of Pb in agricultural soils is one of the most important ecological problems, which potentially results in serious health risk on human health through food chain. Hence, the fate of exogenous Pb contaminated in agricultural soils is needed to be deeply explored. By spiking soils with the stable enriched isotopes of (206)Pb, the contamination of exogenous Pb(2+) ions in three agricultural soils sampled from the estuary areas of Jiulong River, China was simulated in the present study, and the distribution, mobility and bioavailability of exogenous Pb in the soils were investigated using the isotopic labeling method coupled with a four-stage BCR (European Community Bureau of Reference) sequential extraction procedure. Results showed that about 60-85% of exogenous Pb was found to distribute in reducible fractions, while the exogenous Pb in acid-extractable fractions was less than 1.0%. After planting, the amounts of exogenous Pb presenting in acid-extractable, reducible and oxidizable fractions in rhizospheric soils decreased by 60-66%, in which partial exogenous Pb was assimilated by plants while most of the metal might transfer downward due to daily watering and applying fertilizer. The results show that the isotopic labeling technique coupled with sequential extraction procedures enables us to explore the distribution, mobility and bioavailability of exogenous Pb contaminated in soils, which may be useful for the further soil remediation. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Under-reporting of food intake and body fatness in independent older people: a doubly labelled water study.

    PubMed

    Pfrimer, Karina; Vilela, Mariana; Resende, Cristina Maria; Scagliusi, Fernanda Baeza; Marchini, Julio Sergio; Lima, Nereida K C; Moriguti, Julio Cesar; Ferriolli, Eduardo

    2015-01-01

    there are no accurate methods for the assessment of food intake in older populations, under-reporting of intake being highly prevalent. There is controversy about which dietary assessment method and what person's characteristics are associated with greater under-reporting rates. to assess the correlation between under-reporting of energy intake (EI) and different percentages of body fat in independent older people. cross-sectional study. area assisted by the Family Health Program of the Ribeirão Preto Medical School, University of São Paulo, Brazil. one hundred volunteers aged 60-70 years. all volunteers had their body composition assessed by dual-energy x-ray absorptiometry. In second phase, 41 volunteers were evaluated, representing the four quartiles of fat percentage. Total energy expenditure (TEE) was measured by the doubly labelled water method, and EI was assessed by 24-h recalls and a food frequency questionnaire (FFQ). TEE and EI values, EI-to-TEE ratios and EI-TEE values were compared. TEE was 2,220 ± 601 kcal, while the EI was 1,919 ± 602 kcal (24-h recall) and 2,119 ± 670 kcal (FFQ). The proportion of under-reporters was 31 and 40.5%, respectively. Under-reporting was more frequent in subjects with higher percentage of body fat and in females (P < 0.05). under-reporting was more frequent among older persons with higher percentage of body fat in both methods of assessment of food intake. Older persons follow the same profile of under-reporting as younger adults. © The Author 2014. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Flow-aggregated traffic-driven label mapping in label-switching networks

    NASA Astrophysics Data System (ADS)

    Nagami, Kenichi; Katsube, Yasuhiro; Esaki, Hiroshi; Nakamura, Osamu

    1998-12-01

    Label switching technology enables high performance, flexible, layer-3 packet forwarding based on the fixed length label information mapped to the layer-3 packet stream. A Label Switching Router (LSR) forwards layer-3 packets based on their label information mapped to the layer-3 address information as well as their layer-3 address information. This paper evaluates the required number of labels under traffic-driven label mapping policy using the real backbone traffic traces. The evaluation shows that the label mapping policy requires a large number of labels. In order to reduce the required number of labels, we propose a label mapping policy which is a traffic-driven label mapping for the traffic toward the same destination network. The evaluation shows that the proposed label mapping policy requires only about one tenth as many labels compared with the traffic-driven label mapping for the host-pair packet stream,and the topology-driven label mapping for the destination network packet stream.

  8. Nutrition Label Viewing during a Food-Selection Task: Front-of-Package Labels vs Nutrition Facts Labels.

    PubMed

    Graham, Dan J; Heidrick, Charles; Hodgin, Katie

    2015-10-01

    Earlier research has identified consumer characteristics associated with viewing Nutrition Facts labels; however, little is known about those who view front-of-package nutrition labels. Front-of-package nutrition labels might appeal to more consumers than do Nutrition Facts labels, but it might be necessary to provide consumers with information about how to locate and use these labels. This study quantifies Nutrition Facts and front-of-package nutrition label viewing among American adult consumers. Attention to nutrition information was measured during a food-selection task. One hundred and twenty-three parents (mean age=38 years, mean body mass index [calculated as kg/m(2)]=28) and one of their children (aged 6 to 9 years) selected six foods from a university laboratory-turned-grocery aisle. Participants were randomized to conditions in which front-of-package nutrition labels were present or absent, and signage explaining front-of-package nutrition labels was present or absent. Adults' visual attention to Nutrition Facts labels and front-of-package nutrition labels was objectively measured via eye-tracking glasses. To examine whether there were significant differences in the percentages of participants who viewed Nutrition Facts labels vs front-of-package nutrition labels, McNemar's tests were conducted across all participants, as well as within various sociodemographic categories. To determine whether hypothesized factors, such as health literacy and education, had stronger relationships with front-of-package nutrition label vs Nutrition Facts label viewing, linear regression assessed the magnitude of relationships between theoretically and empirically derived factors and each type of label viewing. Overall, front-of-package nutrition labels were more likely to be viewed than Nutrition Facts labels; however, for all subgroups, higher rates of front-of-package nutrition label viewership occurred only when signage was present drawing attention to the presence and

  9. A systematic evaluation of normalization methods in quantitative label-free proteomics.

    PubMed

    Välikangas, Tommi; Suomi, Tomi; Elo, Laura L

    2018-01-01

    To date, mass spectrometry (MS) data remain inherently biased as a result of reasons ranging from sample handling to differences caused by the instrumentation. Normalization is the process that aims to account for the bias and make samples more comparable. The selection of a proper normalization method is a pivotal task for the reliability of the downstream analysis and results. Many normalization methods commonly used in proteomics have been adapted from the DNA microarray techniques. Previous studies comparing normalization methods in proteomics have focused mainly on intragroup variation. In this study, several popular and widely used normalization methods representing different strategies in normalization are evaluated using three spike-in and one experimental mouse label-free proteomic data sets. The normalization methods are evaluated in terms of their ability to reduce variation between technical replicates, their effect on differential expression analysis and their effect on the estimation of logarithmic fold changes. Additionally, we examined whether normalizing the whole data globally or in segments for the differential expression analysis has an effect on the performance of the normalization methods. We found that variance stabilization normalization (Vsn) reduced variation the most between technical replicates in all examined data sets. Vsn also performed consistently well in the differential expression analysis. Linear regression normalization and local regression normalization performed also systematically well. Finally, we discuss the choice of a normalization method and some qualities of a suitable normalization method in the light of the results of our evaluation. © The Author 2016. Published by Oxford University Press.

  10. 99mTc: Labeling Chemistry and Labeled Compounds

    NASA Astrophysics Data System (ADS)

    Alberto, R.; Abram, U.

    This chapter reviews the radiopharmaceutical chemistry of technetium related to the synthesis of perfusion agents and to the labeling of receptor-binding biomolecules. To understand the limitations of technetium chemistry imposed by future application of the complexes in nuclear medicine, an introductory section analyzes the compulsory requirements to be considered when facing the incentive of introducing a novel radiopharmaceutical into the market. Requirements from chemistry, routine application, and market are discussed. In a subsequent section, commercially available 99mTc-based radiopharmaceuticals are treated. It covers the complexes in use for imaging the most important target organs such as heart, brain, or kidney. The commercially available radiopharmaceuticals fulfill the requirements outlined earlier and are discussed with this background. In a following section, the properties and perspectives of the different generations of radiopharmaceuticals are described in a general way, covering characteristics for perfusion agents and for receptor-specific molecules. Technetium chemistry for the synthesis of perfusion agents and the different labeling approaches for target-specific biomolecules are summarized. The review comprises a general introduction to the common approaches currently in use, employing the N x S4-x , [3+1] and 2-hydrazino-nicotinicacid (HYNIC) method as well as more recent strategies such as the carbonyl and the TcN approach. Direct labeling without the need of a bifunctional chelator is briefly reviewed as well. More particularly, recent developments in the labeling of concrete targeting molecules, the second generation of radiopharmaceuticals, is then discussed and prominent examples with antibodies/peptides, neuroreceptor targeting small molecules, myocardial imaging agents, vitamins, thymidine, and complexes relevant to multidrug resistance are given. In addition, a new approach toward peptide drug development is described. The section

  11. Nonlocal atlas-guided multi-channel forest learning for human brain labeling

    PubMed Central

    Ma, Guangkai; Gao, Yaozong; Wu, Guorong; Wu, Ligang; Shen, Dinggang

    2016-01-01

    Purpose: It is important for many quantitative brain studies to label meaningful anatomical regions in MR brain images. However, due to high complexity of brain structures and ambiguous boundaries between different anatomical regions, the anatomical labeling of MR brain images is still quite a challenging task. In many existing label fusion methods, appearance information is widely used. However, since local anatomy in the human brain is often complex, the appearance information alone is limited in characterizing each image point, especially for identifying the same anatomical structure across different subjects. Recent progress in computer vision suggests that the context features can be very useful in identifying an object from a complex scene. In light of this, the authors propose a novel learning-based label fusion method by using both low-level appearance features (computed from the target image) and high-level context features (computed from warped atlases or tentative labeling maps of the target image). Methods: In particular, the authors employ a multi-channel random forest to learn the nonlinear relationship between these hybrid features and target labels (i.e., corresponding to certain anatomical structures). Specifically, at each of the iterations, the random forest will output tentative labeling maps of the target image, from which the authors compute spatial label context features and then use in combination with original appearance features of the target image to refine the labeling. Moreover, to accommodate the high inter-subject variations, the authors further extend their learning-based label fusion to a multi-atlas scenario, i.e., they train a random forest for each atlas and then obtain the final labeling result according to the consensus of results from all atlases. Results: The authors have comprehensively evaluated their method on both public LONI_LBPA40 and IXI datasets. To quantitatively evaluate the labeling accuracy, the authors use the

  12. Nonlocal atlas-guided multi-channel forest learning for human brain labeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, Guangkai; Gao, Yaozong; Wu, Guorong

    Purpose: It is important for many quantitative brain studies to label meaningful anatomical regions in MR brain images. However, due to high complexity of brain structures and ambiguous boundaries between different anatomical regions, the anatomical labeling of MR brain images is still quite a challenging task. In many existing label fusion methods, appearance information is widely used. However, since local anatomy in the human brain is often complex, the appearance information alone is limited in characterizing each image point, especially for identifying the same anatomical structure across different subjects. Recent progress in computer vision suggests that the context features canmore » be very useful in identifying an object from a complex scene. In light of this, the authors propose a novel learning-based label fusion method by using both low-level appearance features (computed from the target image) and high-level context features (computed from warped atlases or tentative labeling maps of the target image). Methods: In particular, the authors employ a multi-channel random forest to learn the nonlinear relationship between these hybrid features and target labels (i.e., corresponding to certain anatomical structures). Specifically, at each of the iterations, the random forest will output tentative labeling maps of the target image, from which the authors compute spatial label context features and then use in combination with original appearance features of the target image to refine the labeling. Moreover, to accommodate the high inter-subject variations, the authors further extend their learning-based label fusion to a multi-atlas scenario, i.e., they train a random forest for each atlas and then obtain the final labeling result according to the consensus of results from all atlases. Results: The authors have comprehensively evaluated their method on both public LONI-LBPA40 and IXI datasets. To quantitatively evaluate the labeling accuracy, the authors

  13. 16 CFR 305.10 - Ranges of comparability on the required labels.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... cost. The Representative Average Unit Energy Cost figures to be used on labels as required by § 305.11... Commission shall publish revised Representative Average Unit Energy Cost figures in the Federal Register in... ACTS OF CONGRESS ENERGY AND WATER USE LABELING FOR CONSUMER PRODUCTS UNDER THE ENERGY POLICY AND...

  14. In vitro labelling and detection of mesenchymal stromal cells: a comparison between magnetic resonance imaging of iron-labelled cells and magnetic resonance spectroscopy of fluorine-labelled cells.

    PubMed

    Rizzo, Stefania; Petrella, Francesco; Zucca, Ileana; Rinaldi, Elena; Barbaglia, Andrea; Padelli, Francesco; Baggi, Fulvio; Spaggiari, Lorenzo; Bellomi, Massimo; Bruzzone, Maria Grazia

    2017-01-01

    Among the various stem cell populations used for cell therapy, adult mesenchymal stromal cells (MSCs) have emerged as a major new cell technology. These cells must be tracked after transplantation to monitor their migration within the body and quantify their accumulation at the target site. This study assessed whether rat bone marrow MSCs can be labelled with superparamagnetic iron oxide (SPIO) nanoparticles and perfluorocarbon (PFC) nanoemulsion formulations without altering cell viability and compared magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) results from iron-labelled and fluorine-labelled MSCs, respectively. Of MSCs, 2 × 10 6 were labelled with Molday ION Rhodamine-B (MIRB) and 2 × 10 6 were labelled with Cell Sense. Cell viability was evaluated by trypan blue exclusion method. Labelled MSCs were divided into four samples containing increasing cell numbers (0.125 × 10 6 , 0.25 × 10 6 , 0.5 × 10 6 , 1 × 10 6 ) and scanned on a 7T MRI: for MIRB-labelled cells, phantoms and cells negative control, T1, T2 and T2* maps were acquired; for Cell Sense labelled cells, phantoms and unlabelled cells, a 19 F non-localised single-pulse MRS sequence was acquired. In total, 86.8% and 83.6% of MIRB-labelled cells and Cell Sense-labelled cells were viable, respectively. MIRB-labelled cells were visible in all samples with different cell numbers; pellets containing 0.5 × 10 6 and 1 × 10 6 of Cell Sense-labelled cells showed a detectable 19 F signal. Our data support the use of both types of contrast material (SPIO and PFC) for MSCs labelling, although further efforts should be dedicated to improve the efficiency of PFC labelling.

  15. A systematic review of calorie labeling and modified calorie labeling interventions: Impact on consumer and restaurant behavior

    PubMed Central

    Bleich, Sara N.; Economos, Christina D.; Spiker, Marie L.; Vercammen, Kelsey; VanEpps, Eric M.; Block, Jason P.; Elbel, Brian; Story, Mary; Roberto, Christina A.

    2017-01-01

    Background Evidence on the effects of restaurant calorie labeling on consumer and restaurant behavior is mixed. This paper examined: 1) consumer responses to calorie information alone or compared to modified calorie information, and 2) changes in restaurant offerings following or in advance of menu labeling implementation. Methods We searched PubMed, Web of Science, Policy File and PAIS International to identify restaurant calorie labeling studies through October 1, 2016, that measured calories ordered, consumed, or available for purchase on restaurant menus. We also searched reference lists of calorie labeling articles. Results Fifty-three studies were included: 18 in real-world restaurants, 9 in cafeterias, and 21 in laboratory or simulation settings. Five examined restaurant offerings. Conclusion Due to a lack of well-powered studies with strong designs, the degree to which menu labeling encourages lower calorie purchases and whether that translates to a healthier population is unclear. Although there is limited evidence that menu labeling affects calories purchased at fast-food restaurants, some evidence demonstrates that it lowers calories purchased at certain types of restaurants and in cafeteria settings. The limited data on modified calorie labels find that such labels can encourage lower-calorie purchases, but may not differ in effects relative to calorie labels alone. PMID:29045080

  16. Reconciling Estimates of Cell Proliferation from Stable Isotope Labeling Experiments

    PubMed Central

    Drylewicz, Julia; Elemans, Marjet; Zhang, Yan; Kelly, Elizabeth; Reljic, Rajko; Tesselaar, Kiki; de Boer, Rob J.; Macallan, Derek C.; Borghans, José A. M.; Asquith, Becca

    2015-01-01

    Stable isotope labeling is the state of the art technique for in vivo quantification of lymphocyte kinetics in humans. It has been central to a number of seminal studies, particularly in the context of HIV-1 and leukemia. However, there is a significant discrepancy between lymphocyte proliferation rates estimated in different studies. Notably, deuterated 2H2-glucose (D2-glucose) labeling studies consistently yield higher estimates of proliferation than deuterated water (D2O) labeling studies. This hampers our understanding of immune function and undermines our confidence in this important technique. Whether these differences are caused by fundamental biochemical differences between the two compounds and/or by methodological differences in the studies is unknown. D2-glucose and D2O labeling experiments have never been performed by the same group under the same experimental conditions; consequently a direct comparison of these two techniques has not been possible. We sought to address this problem. We performed both in vitro and murine in vivo labeling experiments using identical protocols with both D2-glucose and D2O. This showed that intrinsic differences between the two compounds do not cause differences in the proliferation rate estimates, but that estimates made using D2-glucose in vivo were susceptible to difficulties in normalization due to highly variable blood glucose enrichment. Analysis of three published human studies made using D2-glucose and D2O confirmed this problem, particularly in the case of short term D2-glucose labeling. Correcting for these inaccuracies in normalization decreased proliferation rate estimates made using D2-glucose and slightly increased estimates made using D2O; thus bringing the estimates from the two methods significantly closer and highlighting the importance of reliable normalization when using this technique. PMID:26437372

  17. Characterization and relative quantification of phospholipids based on methylation and stable isotopic labeling[S

    PubMed Central

    Cai, Tanxi; Shu, Qingbo; Liu, Peibin; Niu, Lili; Guo, Xiaojing; Ding, Xiang; Xue, Peng; Xie, Zhensheng; Wang, Jifeng; Zhu, Nali; Wu, Peng; Niu, Lili; Yang, Fuquan

    2016-01-01

    Phospholipids (PLs), one of the lipid categories, are not only the primary building blocks of cellular membranes, but also can be split to produce products that function as second messengers in signal transduction and play a pivotal role in numerous cellular processes, including cell growth, survival, and motility. Here, we present an integrated novel method that combines a fast and robust TMS-diazomethane-based phosphate derivatization and isotopic labeling strategy, which enables simultaneous profiling and relative quantification of PLs from biological samples. Our results showed that phosphate methylation allows fast and sensitive identification of the six major PL classes, including their lysophospholipid counterparts, under positive ionization mode. The isotopic labeling of endogenous PLs was achieved by deuterated diazomethane, which was generated through acid-catalyzed hydrogen/deuterium (H/D) exchange and methanolysis of TMS-diazomethane during the process of phosphate derivatization. The measured H/D ratios of unlabeled and labeled PLs, which were mixed in known proportions, indicated that the isotopic labeling strategy is capable of providing relative quantitation with adequate accuracy, reproducibility, and a coefficient of variation of 9.1%, on average. This novel method offers unique advantages over existing approaches and presents a powerful tool for research of PL metabolism and signaling. PMID:26733148

  18. Walking as a Contributor to Physical Activity in Healthy Older Adults: 2 Week Longitudinal Study Using Accelerometry and the Doubly Labeled Water Method

    PubMed Central

    Bonomi, Alberto G; Westerterp, Klaas R

    2016-01-01

    Background Physical activity is recommended to promote healthy aging. Defining the importance of activities such as walking in achieving higher levels of physical activity might provide indications for interventions. Objective To describe the importance of walking in achieving higher levels of physical activity in older adults. Methods The study included 42 healthy subjects aged between 51 and 84 years (mean body mass index 25.6 kg/m2 [SD 2.6]). Physical activity, walking, and nonwalking activity were monitored with an accelerometer for 2 weeks. Physical activity was quantified by accelerometer-derived activity counts. An algorithm based on template matching and signal power was developed to classify activity counts into nonwalking counts, short walk counts, and long walk counts. Additionally, in a subgroup of 31 subjects energy expenditure was measured using doubly labeled water to derive physical activity level (PAL). Results Subjects had a mean PAL of 1.84 (SD 0.19, range 1.43-2.36). About 20% of the activity time (21% [SD 8]) was spent walking, which accounted for about 40% of the total counts (43% [SD 11]). Short bouts composed 83% (SD 9) of walking time, providing 81% (SD 11) of walking counts. A stepwise regression model to predict PAL included nonwalking counts and short walk counts, explaining 58% of the variance of PAL (standard error of the estimate=0.12). Walking activities produced more counts per minute than nonwalking activities (P<.001). Long walks produced more counts per minute than short walks (P=.001). Nonwalking counts were independent of walking counts (r=−.05, P=.38). Conclusions Walking activities are a major contributor to physical activity in older adults. Walking activities occur at higher intensities than nonwalking activities, which might prevent individuals from engaging in more walking activity. Finally, subjects who engage in more walking activities do not tend to compensate by limiting nonwalking activities. Trial Registration

  19. A universal procedure for primer labelling of amplicons.

    PubMed Central

    Neilan, B A; Wilton, A N; Jacobs, D

    1997-01-01

    Detection and visualisation of nucleic acids is integral to genome analyses. Exponential amplification procedures have provided the means for the manipulation of nucleic acid sequences, which were otherwise inaccessible. We describe the development and application of a universal method for the labelling of any PCR product using a single end-labelled primer. Amplification was performed in a single reaction with the resulting amplicon labelled to a high specific activity. The method was adapted to a wide range of PCRs and significantly reduced the expense of such analyses. PMID:9207046

  20. Multi-Isotope Secondary Ion Mass Spectrometry Combining Heavy Water 2H with 15N Labeling As Complementary Tracers for Metabolic Heterogeneity at the Single-Cell Level

    NASA Astrophysics Data System (ADS)

    Kopf, S.; McGlynn, S.; Cowley, E.; Green, A.; Newman, D. K.; Orphan, V. J.

    2014-12-01

    Metabolic rates of microbial communities constitute a key physiological parameter for understanding the in situ growth constraints for life in any environment. Isotope labeling techniques provide a powerful approach for measuring such biological activity, due to the use of isotopically enriched substrate tracers whose incorporation into biological materials can be detected with high sensitivity by isotope-ratio mass spectrometry. Nano-meter scale secondary ion mass spectrometry (NanoSIMS) combined with stable isotope labeling provides a unique tool for studying the spatiometabolic activity of microbial populations at the single cell level in order to assess both community structure and population diversity. However, assessing the distribution and range of microbial activity in complex environmental systems with slow-growing organisms, diverse carbon and nitrogen sources, or heterotrophic subpopulations poses a tremendous technical challenge because the introduction of isotopically labeled substrates frequently changes the nutrient availability and can inflate or bias measures of activity. Here, we present the use of hydrogen isotope labeling with deuterated water as an important new addition to the isotopic toolkit and apply it for the determination of single cell microbial activities by NanoSIMS imaging. This tool provides a labeling technique that minimally alters any aquatic chemical environment, can be administered with strong labels even in minimal addition (natural background is very low), is an equally universal substrate for all forms of life even in complex, carbon and nitrogen saturated systems, and can be combined with other isotopic tracers. The combination of heavy water labeling with the most commonly used NanoSIMS tracer, 15N, is technically challenging but opens up a powerful new set of multi-tracer experiments for the study of microbial activity in complex communities. We present the first truly simultaneous single cell triple isotope system

  1. Water demand forecasting: review of soft computing methods.

    PubMed

    Ghalehkhondabi, Iman; Ardjmand, Ehsan; Young, William A; Weckman, Gary R

    2017-07-01

    Demand forecasting plays a vital role in resource management for governments and private companies. Considering the scarcity of water and its inherent constraints, demand management and forecasting in this domain are critically important. Several soft computing techniques have been developed over the last few decades for water demand forecasting. This study focuses on soft computing methods of water consumption forecasting published between 2005 and 2015. These methods include artificial neural networks (ANNs), fuzzy and neuro-fuzzy models, support vector machines, metaheuristics, and system dynamics. Furthermore, it was discussed that while in short-term forecasting, ANNs have been superior in many cases, but it is still very difficult to pick a single method as the overall best. According to the literature, various methods and their hybrids are applied to water demand forecasting. However, it seems soft computing has a lot more to contribute to water demand forecasting. These contribution areas include, but are not limited, to various ANN architectures, unsupervised methods, deep learning, various metaheuristics, and ensemble methods. Moreover, it is found that soft computing methods are mainly used for short-term demand forecasting.

  2. PRN 95-1: Effluent Discharge Labeling Statements

    EPA Pesticide Factsheets

    This notice exempts certain pesticide products from bearing effluent discharge labeling statements specified by P.R. Notice 93-10 for manufacturing use products and end use products that may be discharged to waters of the U.S. or municipal sewer systems.

  3. Performance limitations of label-free sensors in molecular diagnosis using complex samples

    NASA Astrophysics Data System (ADS)

    Varma, Manoj

    2016-03-01

    Label-free biosensors promised a paradigm involving direct detection of biomarkers from complex samples such as serum without requiring multistep sample processing typical of labelled methods such as ELISA or immunofluorescence assays. Label-free sensors have witnessed decades of development with a veritable zoo of techniques available today exploiting a multitude of physical effects. It is appropriate now to critically assess whether label-free technologies have succeeded in delivering their promise with respect to diagnostic applications, particularly, ambitious goals such as early cancer detection using serum biomarkers, which require low limits of detection (LoD). Comparison of nearly 120 limits of detection (LoD) values reported by labelled and label-free sensing approaches over a wide range of detection techniques and target molecules in serum revealed that labeled techniques achieve 2-3 orders of magnitude better LoDs. Data from experiments where labelled and label-free assays were performed simultaneously using the same assay parameters also confirm that the LoD achieved by labelled techniques is 2 to 3 orders of magnitude better than that by label-free techniques. Furthermore, label-free techniques required significant signal amplification, for e.g. using nanoparticle conjugated secondary antibodies, to achieve LoDs comparable to labelled methods substantially deviating from the original "direct detection" paradigm. This finding has important implications on the practical limits of applying label-free detection methods for molecular diagnosis.

  4. Multi-label literature classification based on the Gene Ontology graph.

    PubMed

    Jin, Bo; Muller, Brian; Zhai, Chengxiang; Lu, Xinghua

    2008-12-08

    The Gene Ontology is a controlled vocabulary for representing knowledge related to genes and proteins in a computable form. The current effort of manually annotating proteins with the Gene Ontology is outpaced by the rate of accumulation of biomedical knowledge in literature, which urges the development of text mining approaches to facilitate the process by automatically extracting the Gene Ontology annotation from literature. The task is usually cast as a text classification problem, and contemporary methods are confronted with unbalanced training data and the difficulties associated with multi-label classification. In this research, we investigated the methods of enhancing automatic multi-label classification of biomedical literature by utilizing the structure of the Gene Ontology graph. We have studied three graph-based multi-label classification algorithms, including a novel stochastic algorithm and two top-down hierarchical classification methods for multi-label literature classification. We systematically evaluated and compared these graph-based classification algorithms to a conventional flat multi-label algorithm. The results indicate that, through utilizing the information from the structure of the Gene Ontology graph, the graph-based multi-label classification methods can significantly improve predictions of the Gene Ontology terms implied by the analyzed text. Furthermore, the graph-based multi-label classifiers are capable of suggesting Gene Ontology annotations (to curators) that are closely related to the true annotations even if they fail to predict the true ones directly. A software package implementing the studied algorithms is available for the research community. Through utilizing the information from the structure of the Gene Ontology graph, the graph-based multi-label classification methods have better potential than the conventional flat multi-label classification approach to facilitate protein annotation based on the literature.

  5. Label Review Training: Module 1: Label Basics, Page 21

    EPA Pesticide Factsheets

    This module of the pesticide label review training provides basic information about pesticides, their labeling and regulation, and the core principles of pesticide label review. Learn about types of labels.

  6. Label Review Training: Module 1: Label Basics, Page 20

    EPA Pesticide Factsheets

    This module of the pesticide label review training provides basic information about pesticides, their labeling and regulation, and the core principles of pesticide label review. This section focuses on supplemental labeling.

  7. Label Review Training: Module 1: Label Basics, Page 22

    EPA Pesticide Factsheets

    This module of the pesticide label review training provides basic information about pesticides, their labeling and regulation, and the core principles of pesticide label review. Learn about what labels require review.

  8. Label Review Training: Module 1: Label Basics, Page 19

    EPA Pesticide Factsheets

    This module of the pesticide label review training provides basic information about pesticides, their labeling and regulation, and the core principles of pesticide label review. This section covers supplemental distributor labeling.

  9. Waveguide-type optical circuits for recognition of optical 8QAM-coded label

    NASA Astrophysics Data System (ADS)

    Surenkhorol, Tumendemberel; Kishikawa, Hiroki; Goto, Nobuo; Gonchigsumlaa, Khishigjargal

    2017-10-01

    Optical signal processing is expected to be applied in network nodes. In photonic routers, label recognition is one of the important functions. We have studied different kinds of label recognition methods so far for on-off keying, binary phase-shift keying, quadrature phase-shift keying, and 16 quadrature amplitude modulation-coded labels. We propose a method based on waveguide circuits to recognize an optical eight quadrature amplitude modulation (8QAM)-coded label by simple passive optical signal processing. The recognition of the proposed method is theoretically analyzed and numerically simulated by the finite difference beam propagation method. The noise tolerance is discussed, and bit-error rate against optical signal-to-noise ratio is evaluated. The scalability of the proposed method is also discussed theoretically for two-symbol length 8QAM-coded labels.

  10. Probabilistic atlas based labeling of the cerebral vessel tree

    NASA Astrophysics Data System (ADS)

    Van de Giessen, Martijn; Janssen, Jasper P.; Brouwer, Patrick A.; Reiber, Johan H. C.; Lelieveldt, Boudewijn P. F.; Dijkstra, Jouke

    2015-03-01

    Preoperative imaging of the cerebral vessel tree is essential for planning therapy on intracranial stenoses and aneurysms. Usually, a magnetic resonance angiography (MRA) or computed tomography angiography (CTA) is acquired from which the cerebral vessel tree is segmented. Accurate analysis is helped by the labeling of the cerebral vessels, but labeling is non-trivial due to anatomical topological variability and missing branches due to acquisition issues. In recent literature, labeling the cerebral vasculature around the Circle of Willis has mainly been approached as a graph-based problem. The most successful method, however, requires the definition of all possible permutations of missing vessels, which limits application to subsets of the tree and ignores spatial information about the vessel locations. This research aims to perform labeling using probabilistic atlases that model spatial vessel and label likelihoods. A cerebral vessel tree is aligned to a probabilistic atlas and subsequently each vessel is labeled by computing the maximum label likelihood per segment from label-specific atlases. The proposed method was validated on 25 segmented cerebral vessel trees. Labeling accuracies were close to 100% for large vessels, but dropped to 50-60% for small vessels that were only present in less than 50% of the set. With this work we showed that using solely spatial information of the vessel labels, vessel segments from stable vessels (>50% presence) were reliably classified. This spatial information will form the basis for a future labeling strategy with a very loose topological model.

  11. Label Review Training: Module 1: Label Basics, Page 18

    EPA Pesticide Factsheets

    This module of the pesticide label review training provides basic information about pesticides, their labeling and regulation, and the core principles of pesticide label review. This section discusses the types of labels.

  12. Label Review Training: Module 1: Label Basics, Page 26

    EPA Pesticide Factsheets

    This module of the pesticide label review training provides basic information about pesticides, their labeling and regulation, and the core principles of pesticide label review. Learn about mandatory and advisory label statements.

  13. Label Review Training: Module 1: Label Basics, Page 15

    EPA Pesticide Factsheets

    This module of the pesticide label review training provides basic information about pesticides, their labeling and regulation, and the core principles of pesticide label review. Learn about the consequences of improper labeling.

  14. Label Review Training: Module 1: Label Basics, Page 14

    EPA Pesticide Factsheets

    This module of the pesticide label review training provides basic information about pesticides, their labeling and regulation, and the core principles of pesticide label review. Learn about positive effects from proper labeling.

  15. Label Review Training: Module 1: Label Basics, Page 24

    EPA Pesticide Factsheets

    This module of the pesticide label review training provides basic information about pesticides, their labeling and regulation, and the core principles of pesticide label review. This page is about which labels require review.

  16. Label Review Training: Module 1: Label Basics, Page 17

    EPA Pesticide Factsheets

    This module of the pesticide label review training provides basic information about pesticides, their labeling and regulation, and the core principles of pesticide label review. See an overview of the importance of labels.

  17. Label Review Training: Module 1: Label Basics, Page 27

    EPA Pesticide Factsheets

    This module of the pesticide label review training provides basic information about pesticides, their labeling and regulation, and the core principles of pesticide label review. See examples of mandatory and advisory label statements.

  18. Focal adhesion interactions with topographical structures: a novel method for immuno-SEM labelling of focal adhesions in S-phase cells.

    PubMed

    Biggs, M J P; Richards, R G; Wilkinson, C D W; Dalby, M J

    2008-07-01

    Current understanding of the mechanisms involved in osseointegration following implantation of a biomaterial has led to adhesion quantification being implemented as an assay of cytocompatibility. Such measurement can be hindered by intra-sample variation owing to morphological changes associated with the cell cycle. Here we report on a new scanning electron microscopical method for the simultaneous immunogold labelling of cellular focal adhesions and S-phase nuclei identified by BrdU incorporation. Prior to labelling, cellular membranes are removed by tritonization and antigens of non-interest blocked by serum incubation. Adhesion plaque-associated vinculin and S-phase nuclei were both separately labelled with a 1.4 nm gold colloid and visualized by subsequent colloid enhancement via silver deposition. This study is specifically concerned with the effects microgroove topographies have on adhesion formation in S-phase osteoblasts. By combining backscattered electron (BSE) imaging with secondary electron (SE) imaging it was possible to visualize S-phase nuclei and the immunogold-labelled adhesion sites in one energy 'plane' and the underlying nanotopography in another. Osteoblast adhesion to these nanotopographies was ascertained by quantification of adhesion complex formation.

  19. WaterSense Partners

    EPA Pesticide Factsheets

    WaterSense partners are ambassadors that promote the value of water efficiency and WaterSense-labeled products, new homes, and programs. Partners help educate communities while transforming the marketplace.

  20. Label Review Training: Module 1: Label Basics, Page 23

    EPA Pesticide Factsheets

    This module of the pesticide label review training provides basic information about pesticides, their labeling and regulation, and the core principles of pesticide label review. Lists types of labels that do not require review.

  1. Reported Energy Intake Accuracy Compared to Doubly Labeled Water and Usability of the Mobile Food Record among Community Dwelling Adults.

    PubMed

    Boushey, Carol J; Spoden, Melissa; Delp, Edward J; Zhu, Fengqing; Bosch, Marc; Ahmad, Ziad; Shvetsov, Yurii B; DeLany, James P; Kerr, Deborah A

    2017-03-22

    The mobile Food Record (mFR) is an image-based dietary assessment method for mobile devices. The study primary aim was to test the accuracy of the mFR by comparing reported energy intake (rEI) to total energy expenditure (TEE) using the doubly labeled water (DLW) method. Usability of the mFR was assessed by questionnaires before and after the study. Participants were 45 community dwelling men and women, 21-65 years. They were provided pack-out meals and snacks and encouraged to supplement with usual foods and beverages not provided. After being dosed with DLW, participants were instructed to record all eating occasions over a 7.5 days period using the mFR. Three trained analysts estimated rEI from the images sent to a secure server. rEI and TEE correlated significantly (Spearman correlation coefficient of 0.58, p < 0.0001). The mean percentage of underreporting below the lower 95% confidence interval of the ratio of rEI to TEE was 12% for men (standard deviation (SD) ± 11%) and 10% for women (SD ± 10%). The results demonstrate the accuracy of the mFR is comparable to traditional dietary records and other image-based methods. No systematic biases could be found. The mFR was received well by the participants and usability was rated as easy.

  2. 33 CFR 66.01-14 - Label affixed by manufacturer.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Label affixed by manufacturer. 66.01-14 Section 66.01-14 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION PRIVATE AIDS TO NAVIGATION Aids to Navigation Other Than Federal or State § 66.01-14...

  3. 33 CFR 66.01-14 - Label affixed by manufacturer.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Label affixed by manufacturer. 66.01-14 Section 66.01-14 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION PRIVATE AIDS TO NAVIGATION Aids to Navigation Other Than Federal or State § 66.01-14...

  4. 33 CFR 66.01-14 - Label affixed by manufacturer.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 1 2013-07-01 2013-07-01 false Label affixed by manufacturer. 66.01-14 Section 66.01-14 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION PRIVATE AIDS TO NAVIGATION Aids to Navigation Other Than Federal or State § 66.01-14...

  5. 33 CFR 66.01-14 - Label affixed by manufacturer.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Label affixed by manufacturer. 66.01-14 Section 66.01-14 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION PRIVATE AIDS TO NAVIGATION Aids to Navigation Other Than Federal or State § 66.01-14...

  6. 33 CFR 66.01-14 - Label affixed by manufacturer.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Label affixed by manufacturer. 66.01-14 Section 66.01-14 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION PRIVATE AIDS TO NAVIGATION Aids to Navigation Other Than Federal or State § 66.01-14...

  7. Method Development and Monitoring of Cyanotoxins in Water

    EPA Science Inventory

    This presentation describes method development of two ambient water LC/MS/MS methods for microcystins, cylindrospermopsin and anatoxin-a. Ruggedness of the methods will be demonstrated by evaluation of quality control samples derived from various water bodies across the country.

  8. Label Review Training: Module 1: Label Basics, Page 16

    EPA Pesticide Factsheets

    This module of the pesticide label review training provides basic information about pesticides, their labeling and regulation, and the core principles of pesticide label review. Learn about the importance of labels and the role in enforcement.

  9. A New Method for Preparing Mesenchymal Stem Cells and Labeling with Ferumoxytol for Cell Tracking by MRI.

    PubMed

    Liu, Li; Tseng, Lanya; Ye, Qing; Wu, Yijen L; Bain, Daniel J; Ho, Chien

    2016-05-18

    Mesenchymal stem cells (MSCs) are among the major stem cells used for cell therapy and regenerative medicine. In-vivo cell-tracking by magnetic resonance imaging (MRI) is crucial for regenerative medicine, allowing verification that the transplanted cells reach the targeted sites. Cellular MRI combined with superparamagnetic iron-oxide (SPIO) contrast agents is an effective cell-tracking method. Here, we are reporting a new "bio-mimicry" method by making use of the "in-vivo environment" of MSCs to prepare native MSCs, so that (i) the phagocytic activity of cultured MSCs can be recovered and expanded MSCs can be ex-vivo labeled with Ferumoxytol, which is currently the only FDA approved SPIO nanoparticles for human use. Using our new method, 7-day cultured MSCs regain the capability to take up Ferumoxytol and exhibit an intracellular iron concentration of 2.50 ± 0.50 pg/MSC, comparable to that obtained by using Ferumoxytol-heparin-protamine nanocomplex; and (ii) cells can be re-sized to more native size, reducing from 32.0 ± 7.2 μm to 19.5 ± 5.2 μm. Our method can be very useful for expanding MSCs and labeling with Ferumoxytol, without the need for transfection agents and/or electroporation, allowing cell-tracking by MRI in both pre-clinical and clinical studies.

  10. A New Method for Preparing Mesenchymal Stem Cells and Labeling with Ferumoxytol for Cell Tracking by MRI

    PubMed Central

    Liu, Li; Tseng, Lanya; Ye, Qing; Wu, Yijen L.; Bain, Daniel J.; Ho, Chien

    2016-01-01

    Mesenchymal stem cells (MSCs) are among the major stem cells used for cell therapy and regenerative medicine. In-vivo cell-tracking by magnetic resonance imaging (MRI) is crucial for regenerative medicine, allowing verification that the transplanted cells reach the targeted sites. Cellular MRI combined with superparamagnetic iron-oxide (SPIO) contrast agents is an effective cell-tracking method. Here, we are reporting a new “bio-mimicry” method by making use of the “in-vivo environment” of MSCs to prepare native MSCs, so that (i) the phagocytic activity of cultured MSCs can be recovered and expanded MSCs can be ex-vivo labeled with Ferumoxytol, which is currently the only FDA approved SPIO nanoparticles for human use. Using our new method, 7-day cultured MSCs regain the capability to take up Ferumoxytol and exhibit an intracellular iron concentration of 2.50 ± 0.50 pg/MSC, comparable to that obtained by using Ferumoxytol-heparin-protamine nanocomplex; and (ii) cells can be re-sized to more native size, reducing from 32.0 ± 7.2 μm to 19.5 ± 5.2 μm. Our method can be very useful for expanding MSCs and labeling with Ferumoxytol, without the need for transfection agents and/or electroporation, allowing cell-tracking by MRI in both pre-clinical and clinical studies. PMID:27188664

  11. Tracing nitrogenous disinfection byproducts after medium pressure UV water treatment by stable isotope labeling and high resolution mass spectrometry.

    PubMed

    Kolkman, Annemieke; Martijn, Bram J; Vughs, Dennis; Baken, Kirsten A; van Wezel, Annemarie P

    2015-04-07

    Advanced oxidation processes are important barriers for organic micropollutants (e.g., pharmaceuticals, pesticides) in (drinking) water treatment. Studies indicate that medium pressure (MP) UV/H2O2 treatment leads to a positive response in Ames mutagenicity tests, which is then removed after granulated activated carbon (GAC) filtration. The formed potentially mutagenic substances were hitherto not identified and may result from the reaction of photolysis products of nitrate with (photolysis products of) natural organic material (NOM). In this study we present an innovative approach to trace the formation of disinfection byproducts (DBPs) of MP UV water treatment, based on stable isotope labeled nitrate combined with high resolution mass spectrometry. It was shown that after MP UV treatment of artificial water containing NOM and nitrate, multiple nitrogen containing substances were formed. In total 84 N-DBPs were detected at individual concentrations between 1 to 135 ng/L bentazon-d6 equivalents, with a summed concentration of 1.2 μg/L bentazon-d6 equivalents. The chemical structures of three byproducts were confirmed. Screening for the 84 N-DBPs in water samples from a full-scale drinking water treatment plant based on MP UV/H2O2 treatment showed that 22 of the N-DBPs found in artificial water were also detected in real water samples.

  12. IRMS detection of testosterone manipulated with 13C labeled standards in human urine by removing the labeled 13C.

    PubMed

    Wang, Jingzhu; Yang, Rui; Yang, Wenning; Liu, Xin; Xing, Yanyi; Xu, Youxuan

    2014-12-10

    Isotope ratio mass spectrometry (IRMS) is applied to confirm testosterone (T) abuse by determining the carbon isotope ratios (δ(13)C value). However, (13)C labeled standards can be used to control the δ(13)C value and produce manipulated T which cannot be detected by the current method. A method was explored to remove the (13)C labeled atom at C-3 from the molecule of androsterone (Andro), the metabolite of T in urine, to produce the resultant (A-nor-5α-androstane-2,17-dione, ANAD). The difference in δ(13)C values between Andro and ANAD (Δδ(13)CAndro-ANAD, ‰) would change significantly in case manipulated T is abused. Twenty-one volunteers administered T manipulated with different (13)C labeled standards. The collected urine samples were analyzed with the established method, and the maximum value of Δδ(13)CAndro-ANAD post ingestion ranged from 3.0‰ to 8.8‰. Based on the population reference, the cut-off value of Δδ(13)CAndro-ANAD for positive result was suggested as 1.2‰. The developed method could be used to detect T manipulated with 3-(13)C labeled standards. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Improved methods for national water assessment, water resources contract: WR15249270

    USGS Publications Warehouse

    Thomas, Harold A.

    1981-01-01

    The purpose of our research is to develop methods to make National Water Assessment more useful in estimating water availability for economic growth and more helpful in determining the effect of water resource development upon the environmental quality of related land resources. There are serious questions pertaining to the 1975 Water Assessment and these amplify the significance of decisions made as to the planning and scheduling of the next assessment.

  14. New effects in Langmuir and Langmuir-Blodgett monolayers from fluorescently labelled phospholipids and their possible use for water quality control

    NASA Astrophysics Data System (ADS)

    Ivanov, G. R.; Geshev, N. I.

    2016-02-01

    Secondary water contamination poses significant challenges to the sensitivity and selectivity of sensors used for its detection and monitoring. Currently only lab tests can detect these contaminants and by the time this happens the contaminated water has entered the city water supply system. Fluorescent chromophore NitroBenzoxaDiazole (NBD) is very suitable and had been successfully used in biosensor applications due to its high sensitivity to close proximity polarity of the medium. Over the years we have discovered 3 new effects in NBD- labelled phospholipids which can significantly improve the performance of biosensors. The phospholipid matrix provides flexible biocompatible environment for immobilization of selectively reacting enzymes, microorganisms, DNA, immunoagents, whole cells. Use of single layer (3.1 nm thickness) films at the air-water interface (Langmuir films) or deposited on solid support as Langmuir-Blodgett (LB) film gives fast response times for real time monitoring (no slow diffusion processes) and precise molecule ordering and orientation. The first new effect was fluorescence self-quenching in Langmuir and LB films. In the liquid phase films exhibit normal fluorescence. Upon transition to solid phase fluorescence intensity is almost completely self-quenched and fluorescence lifetimes in the nanosecond region decrease 2 times. This is easily measured. Usually large heavy metal atoms quench fluorescence. We observed the opposite new effect when LB film is deposited in the solid phase from a subphase containing heavy metals. The third new effect is the obtaining of nanosized cylinders with bilayer thickness, which remain stable at least for months, when LB monolayer is deposited in the phase coexistence region at thermodynamic equilibrium. This greatly increases reacting surface and sensitivity of possible sensors. Almost all possible optical experimental methods were used for this research. This includes polarized ATR FTIR and polarized UV

  15. Environmental labelling in The Netherlands: a framework for integrated farming.

    PubMed

    Manhoudt, A G E; van de Ven, G W J; Udo de Haes, H A; de Snoo, G R

    2002-07-01

    This article compares four Dutch environmental certification schemes for agricultural food crops, analysing their methodology and the completeness of their criteria on five aspects: pesticide use, nutrient use, water management, energy and materials consumption, and habitat management. The least stringent of the labels, the MBT ('Environmentally Aware Cultivation') certificate, serves mainly to increase farmers' awareness of nutrient and pesticide use. With regard to both administrative obligations and actual management practices, the MBT label largely mirrors the terms of standing Dutch legislation. The CC ('Controlled Cultivation') and AMK ('Agro-Environmental') labels comprise more and more stringent criteria. With their restrictions on nutrient and pesticide use, these two labels serve as the two principal labels in the field of integrated agriculture. There is little difference between the two and it is recommended that they be merged, on the basis of a standardised definition of integrated agriculture. The EKO ('Organic Agriculture') label proceeds from different principles, but as a minimum should also comply with Dutch legislation without exception. For both integrated and organic agriculture, in addition to criteria on pesticide and nutrient use, criteria should also be developed for water management, energy and materials use and habitat management. The relationship between the criteria and their respective thresholds and Dutch legislation is also addressed. Existing criteria are frequently specified in such a way that the environmental benefits cannot be ascertained. This is a serious drawback for the parties further down the chain: auctioneers, retailers and consumers. It is recommended to develop qualitative guidelines for an Agricultural Stewardship Council at international level, like the Forest Stewardship Council, and a separate label for integrated agriculture per country comprising quantitative criteria for all relevant aspects of farming

  16. Measuring the labeling efficiency of pseudocontinuous arterial spin labeling.

    PubMed

    Chen, Zhensen; Zhang, Xingxing; Yuan, Chun; Zhao, Xihai; van Osch, Matthias J P

    2017-05-01

    Optimization and validation of a sequence for measuring the labeling efficiency of pseudocontinuous arterial spin labeling (pCASL) perfusion MRI. The proposed sequence consists of a labeling module and a single slice Look-Locker echo planar imaging readout. A model-based algorithm was used to calculate labeling efficiency from the signal acquired from the main brain-feeding arteries. Stability of the labeling efficiency measurement was evaluated with regard to the use of cardiac triggering, flow compensation and vein signal suppression. Accuracy of the measurement was assessed by comparing the measured labeling efficiency to mean brain pCASL signal intensity over a wide range of flip angles as applied in the pCASL labeling. Simulations show that the proposed algorithm can effectively calculate labeling efficiency when correcting for T1 relaxation of the blood spins. Use of cardiac triggering and vein signal suppression improved stability of the labeling efficiency measurement, while flow compensation resulted in little improvement. The measured labeling efficiency was found to be linearly (R = 0.973; P < 0.001) related to brain pCASL signal intensity over a wide range of pCASL flip angles. The optimized labeling efficiency sequence provides robust artery-specific labeling efficiency measurement within a short acquisition time (∼30 s), thereby enabling improved accuracy of pCASL CBF quantification. Magn Reson Med 77:1841-1852, 2017. © 2016 International Society for Magnetic Resonance in Medicine Magn Reson Med 77:1841-1852, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  17. RJMCMC based Text Placement to Optimize Label Placement and Quantity

    NASA Astrophysics Data System (ADS)

    Touya, Guillaume; Chassin, Thibaud

    2018-05-01

    Label placement is a tedious task in map design, and its automation has long been a goal for researchers in cartography, but also in computational geometry. Methods that search for an optimal or nearly optimal solution that satisfies a set of constraints, such as label overlapping, have been proposed in the literature. Most of these methods mainly focus on finding the optimal position for a given set of labels, but rarely allow the removal of labels as part of the optimization. This paper proposes to apply an optimization technique called Reversible-Jump Markov Chain Monte Carlo that enables to easily model the removal or addition during the optimization iterations. The method, quite preliminary for now, is tested on a real dataset, and the first results are encouraging.

  18. [Application of DNA labeling technology in forensic botany].

    PubMed

    Znang, Xian; Li, Jing-Lin; Zhang, Xiang-Yu

    2008-12-01

    Forensic botany is a study of judicial plant evidence. Recently, researches on DNA labeling technology have been a mainstream of forensic botany. The article systematically reviews various types of DNA labeling techniques in forensic botany with enumerated practical cases, as well as the potential forensic application of each individual technique. The advantages of the DNA labeling technology over traditional morphological taxonomic methods are also summarized.

  19. Mass spectrometry–based relative quantification of proteins in precatalytic and catalytically active spliceosomes by metabolic labeling (SILAC), chemical labeling (iTRAQ), and label-free spectral count

    PubMed Central

    Schmidt, Carla; Grønborg, Mads; Deckert, Jochen; Bessonov, Sergey; Conrad, Thomas; Lührmann, Reinhard; Urlaub, Henning

    2014-01-01

    The spliceosome undergoes major changes in protein and RNA composition during pre-mRNA splicing. Knowing the proteins—and their respective quantities—at each spliceosomal assembly stage is critical for understanding the molecular mechanisms and regulation of splicing. Here, we applied three independent mass spectrometry (MS)–based approaches for quantification of these proteins: (1) metabolic labeling by SILAC, (2) chemical labeling by iTRAQ, and (3) label-free spectral count for quantification of the protein composition of the human spliceosomal precatalytic B and catalytic C complexes. In total we were able to quantify 157 proteins by at least two of the three approaches. Our quantification shows that only a very small subset of spliceosomal proteins (the U5 and U2 Sm proteins, a subset of U5 snRNP-specific proteins, and the U2 snRNP-specific proteins U2A′ and U2B′′) remains unaltered upon transition from the B to the C complex. The MS-based quantification approaches classify the majority of proteins as dynamically associated specifically with the B or the C complex. In terms of experimental procedure and the methodical aspect of this work, we show that metabolically labeled spliceosomes are functionally active in terms of their assembly and splicing kinetics and can be utilized for quantitative studies. Moreover, we obtain consistent quantification results from all three methods, including the relatively straightforward and inexpensive label-free spectral count technique. PMID:24448447

  20. Methods for nanoparticle labeling of ricin and effect on toxicity

    NASA Astrophysics Data System (ADS)

    Wark, Alastair W.; Yu, Jun; Lindsay, Christopher D.; Nativo, Paola; Graham, Duncan

    2009-09-01

    The unique optical properties associated with nanostructured materials that support the excitation of surface plasmons offer many new opportunities for the enhanced optical investigation of biological materials that pose a security threat. In particular, ricin is considered a significant bioterrorism risk due to its high toxicity combined with its ready availability as a byproduct in castor oil production. Therefore, the development of optical techniques capable of rapid on-site toxin detection with high molecular specificity and sensitivity continues to be of significant importance. Furthermore, understanding of the ricin cell entry and intracellular pathways remains poor due to a lack of suitable bioanalytical techniques. Initial work aimed at simultaneously tackling both these issues is described where different approaches for the nanoparticle labeling of ricin are investigated along with changes in ricin toxicity associated with the labeling process.

  1. Label-Free, Flow-Imaging Methods for Determination of Cell Concentration and Viability.

    PubMed

    Sediq, A S; Klem, R; Nejadnik, M R; Meij, P; Jiskoot, Wim

    2018-05-30

    To investigate the potential of two flow imaging microscopy (FIM) techniques (Micro-Flow Imaging (MFI) and FlowCAM) to determine total cell concentration and cell viability. B-lineage acute lymphoblastic leukemia (B-ALL) cells of 2 different donors were exposed to ambient conditions. Samples were taken at different days and measured with MFI, FlowCAM, hemocytometry and automated cell counting. Dead and live cells from a fresh B-ALL cell suspension were fractionated by flow cytometry in order to derive software filters based on morphological parameters of separate cell populations with MFI and FlowCAM. The filter sets were used to assess cell viability in the measured samples. All techniques gave fairly similar cell concentration values over the whole incubation period. MFI showed to be superior with respect to precision, whereas FlowCAM provided particle images with a higher resolution. Moreover, both FIM methods were able to provide similar results for cell viability as the conventional methods (hemocytometry and automated cell counting). FIM-based methods may be advantageous over conventional cell methods for determining total cell concentration and cell viability, as FIM measures much larger sample volumes, does not require labeling, is less laborious and provides images of individual cells.

  2. Syntheses of halogen derivatives of L-tryptophan, L-tyrosine and L-phenylalanine labeled with hydrogen isotopes.

    PubMed

    Pająk, Małgorzata; Pałka, Katarzyna; Winnicka, Elżbieta; Kańska, Marianna

    2016-01-01

    Halogenated, labeled with tritium and doubly with deuterium and tritium, derivatives of L-tryptophan, i.e. 5'-bromo-[2-(3)H]-, 5'-bromo-[2-(2)H/(3)H]-, 5'-fluoro-[2-(3)H]-5'-fluoro-[2-(2)H/(3)H]-, 6'-fluoro-[2-(3)H]-, 6'-fluoro-[2-(2)H/(3)H]-L-tryptophan, as well as, L-tyrosine, i.e. 3'-fluoro-[2-(3)H]-, 3'-fluoro-[2-(2)H/(3)H]-, 3'-chloro-[2-(3)H]-, and 3'-chloro-[2-(2)H/(3)H]-L-tyrosine, and also L-phenylalanine, i.e. 2'-fluoro-[(3S)-(3)H]-, 2'-fluoro-[(3S)-(2)H/(3) H]-, 2'-chloro-[(3S)-(3)H]-, 2'-chloro-[(3S)-(2)H/(3)H]-, 4'-chloro-[(3S)-(3)H]-, and 4'-chloro-[(3S)-(2)H/(3)H]-L-phenylalanine were synthesized using enzymatic methods. Isotopomers of L-tryptophan were synthesized by coupling of halogenated indoles with S-methyl-L-cysteine carried out in deuteriated or tritiated incubation media. Labeled halogenated derivatives of L-tyrosine were obtained by the enzymatically supported exchange between halogenated L-tyrosine and isotopic water. Labeled halogenated isotopologues of L-Phe were synthesized by the enzymatic addition of ammonia to halogenated cinnamic acid. As a source of hydrogen tritiated water (HTO) and heavy water (D2O) with addition of HTO were used. Copyright © 2015 John Wiley & Sons, Ltd.

  3. Surface Functionalization Methods to Enhance Bioconjugation in Metal-Labeled Polystyrene Particles

    PubMed Central

    Abdelrahman, Ahmed I.; Thickett, Stuart C.; Liang, Yi; Ornatsky, Olga; Baranov, Vladimir; Winnik, Mitchell A.

    2011-01-01

    Lanthanide-encoded polystyrene particles synthesized by dispersion polymerization are excellent candidates for mass cytometry based immunoassays, however they have previously lacked the ability to conjugate biomolecules to the particle surface. We present here three approaches to post-functionalize these particles, enabling the covalent attachment of proteins. Our first approach used partially hydrolyzed poly(N-vinylpyrrolidone) as a dispersion polymerization stabilizer to synthesize particles with high concentration of -COOH groups on the particle surface. In an alternative strategy to provide -COOH functionality to the lanthanide-encoded particles, we employed seeded emulsion polymerization to graft poly(methacrylic acid) (PMAA) chains onto the surface of these particles. However, these two approaches gave little to no improvement in the extent of bioconjugation. In our third approach, seeded emulsion polymerization was subsequently used as a method to grow a functional polymer shell (in this case, poly(glycidyl methacrylate) (PGMA)) onto the surface of these particles, which proved highly successful. The epoxide-rich PGMA shell permitted extensive surface bioconjugation of NeutrAvidin, as probed by an Lu-labeled biotin reporter (ca. 7 × 105 binding events per particle with a very low amount of non-specific binding) and analyzed by mass cytometry. It was shown that coupling agents such as EDC were not needed, such was the reactivity of the particle surface. These particles were stable and the addition of a polymeric shell was shown did not affect the narrow lanthanide ion distribution within the particle interior as analyzed by mass cytometry. These particles represent the most promising candidates for the development of a highly multiplexed bioassay based on lanthanide-labeled particles to date. PMID:21799543

  4. A Mobile Phone Based Method to Assess Energy and Food Intake in Young Children: A Validation Study against the Doubly Labelled Water Method and 24 h Dietary Recalls.

    PubMed

    Delisle Nyström, Christine; Forsum, Elisabet; Henriksson, Hanna; Trolle-Lagerros, Ylva; Larsson, Christel; Maddison, Ralph; Timpka, Toomas; Löf, Marie

    2016-01-15

    Mobile phones are becoming important instruments for assessing diet and energy intake. We developed the Tool for Energy Balance in Children (TECH), which uses a mobile phone to assess energy and food intake in pre-school children. The aims of this study were: (a) to compare energy intake (EI) using TECH with total energy expenditure (TEE) measured via doubly labelled water (DLW); and (b) to compare intakes of fruits, vegetables, fruit juice, sweetened beverages, candy, ice cream, and bakery products using TECH with intakes acquired by 24 h dietary recalls. Participants were 39 healthy, Swedish children (5.5 ± 0.5 years) within the ongoing Mobile-based Intervention Intended to Stop Obesity in Preschoolers (MINISTOP) obesity prevention trial. Energy and food intakes were assessed during four days using TECH and 24 h telephone dietary recalls. Mean EI (TECH) was not statistically different from TEE (DLW) (5820 ± 820 kJ/24 h and 6040 ± 680 kJ/24 h, respectively). No significant differences in the average food intakes using TECH and 24 h dietary recalls were found. All food intakes were correlated between TECH and the 24 h dietary recalls (ρ = 0.665-0.896, p < 0.001). In conclusion, TECH accurately estimated the average intakes of energy and selected foods and thus has the potential to be a useful tool for dietary studies in pre-school children, for example obesity prevention trials.

  5. A Mobile Phone Based Method to Assess Energy and Food Intake in Young Children: A Validation Study against the Doubly Labelled Water Method and 24 h Dietary Recalls

    PubMed Central

    Delisle Nyström, Christine; Forsum, Elisabet; Henriksson, Hanna; Trolle-Lagerros, Ylva; Larsson, Christel; Maddison, Ralph; Timpka, Toomas; Löf, Marie

    2016-01-01

    Mobile phones are becoming important instruments for assessing diet and energy intake. We developed the Tool for Energy Balance in Children (TECH), which uses a mobile phone to assess energy and food intake in pre-school children. The aims of this study were: (a) to compare energy intake (EI) using TECH with total energy expenditure (TEE) measured via doubly labelled water (DLW); and (b) to compare intakes of fruits, vegetables, fruit juice, sweetened beverages, candy, ice cream, and bakery products using TECH with intakes acquired by 24 h dietary recalls. Participants were 39 healthy, Swedish children (5.5 ± 0.5 years) within the ongoing Mobile-based Intervention Intended to Stop Obesity in Preschoolers (MINISTOP) obesity prevention trial. Energy and food intakes were assessed during four days using TECH and 24 h telephone dietary recalls. Mean EI (TECH) was not statistically different from TEE (DLW) (5820 ± 820 kJ/24 h and 6040 ± 680kJ/24 h, respectively). No significant differences in the average food intakes using TECH and 24 h dietary recalls were found. All food intakes were correlated between TECH and the 24 h dietary recalls (ρ = 0.665–0.896, p < 0.001). In conclusion, TECH accurately estimated the average intakes of energy and selected foods and thus has the potential to be a useful tool for dietary studies in pre-school children, for example obesity prevention trials. PMID:26784226

  6. Method and kit for the selective labeling of red blood cells in whole blood with TC-99M

    DOEpatents

    Srivastava, Suresh C.; Babich, John W.; Straub, Rita; Richards, Powell

    1988-01-01

    Disclosed herein are a method and kit for the preparation of .sup.99m Tc labeled red blood cells using whole blood in a closed sterile system containing stannous tin in a form such that it will enter the red blood cells and be available therein for the reduction of technetium.

  7. Design and Application of Synthetic Receptors for Recognition of Methylated Lysine and Supramolecular Affinity Labeling

    NASA Astrophysics Data System (ADS)

    Gober, Isaiah Nathaniel

    This dissertation involves the design and synthesis of new synthetic receptors and their application in the molecular recognition of methylated lysine and their use as tools for chemical biology. The dissertation is divided into four parts. The first section focuses on the development of a novel labeling method that is based on ligand-directed affinity labeling principles. In this labeling method, a synthetic receptor that binds to trimethyl lysine (Kme3) is attached through a linker to an electrophilic tag group that can react with a nucleophilic amine in a histone peptide. This affinity labeling probe, which we called CX4-ONBD, is equipped with an electrophilic tag that allows for turn-on fluorescence labeling of Kme3 histone peitdes. We show that the probe gives a pronounced turn-on fluorescence response when it is incubated with a histone peptide that contains Kme3 and a nearby reactive lysine. This probe also displays >5-fold selectivity in covalent labeling over an unmethylated lysine peptide. This represents the first time a synthetic receptor has been used for affinity labeling purposes, and it also expands on the chemical toolkit that is available for sensing PTMs like lysine methylation. In the second section, the supramolecular affinity labeling method that was optimized using CX4-ONBD was applied to the development of a real-time assay for measuring enzymatic activity. More specifically, the probe was used to create a turn-on fluorescence assay for histone deacetylase (HDAC) activity and for inhibitor screening and IC50 determination. Most commercial kits for HDAC activity have limited substrate scope, and other common methods used for characterizing enzymatic activity often require chromatographic separation and are therefore not high-throughput. This small molecule receptor-mediated affinity labeling strategy allowed for facile readout of HDAC activity and inhibition. Overall, this application of supramolecular affinity labeling expands on the

  8. Controlling off-label medication use.

    PubMed

    Gillick, Muriel R

    2009-03-03

    Off-label prescribing may lead to innovative new uses of old medications, is essential in such fields as pediatrics, and avoids the lengthy and expensive process of modifying U.S. Food and Drug Administration (FDA) drug labeling. Using medications for unapproved indications, however, raises concerns about patient safety when the drugs have a high potential for toxicity and generates economic concerns when their cost is high. A possible means of controlling the use of off-label drugs is to focus on medications used off-label that are both expensive and potentially risky. These are principally biotechnology drugs, such as recombinant enzymes, cytokines, and monoclonal antibodies. This article suggests a 2-step process for controlling use of such drugs, analogous to that used for devices. Once a drug is FDA approved, it would undergo scrutiny using the Centers for Medicare & Medicaid Services (CMS) National Coverage Determination method if its cost exceeds a specified benchmark-for example, $12 000, which is the average cost of a pacemaker. The CMS would pay only for off-label uses for which there is adequate evidence in its National Coverage Determination process. Other insurance companies would probably adopt the recommendations of CMS.

  9. Improvements to the DRASTIC ground-water vulnerability mapping method

    USGS Publications Warehouse

    Rupert, Michael G.

    1999-01-01

    Ground-water vulnerability maps are designed to show areas of greatest potential for ground-water contamination on the basis of hydrogeologic and anthropogenic (human) factors. The maps are developed by using computer mapping hardware and software called a geographic information system (GIS) to combine data layers such as land use, soils, and depth to water. Usually, ground-water vulnerability is determined by assigning point ratings to the individual data layers and then adding the point ratings together when those layers are combined into a vulnerability map. Probably the most widely used ground-water vulnerability mapping method is DRASTIC, named for the seven factors considered in the method: Depth to water, net Recharge, Aquifer media, Soil media, Topography, Impact of vadose zone media, and hydraulic Conductivity of the aquifer (Aller and others, 1985, p. iv). The DRASTIC method has been used to develop ground-water vulnerability maps in many parts of the Nation; however, the effectiveness of the method has met with mixed success (Koterba and others, 1993, p. 513; U.S. Environmental Protection Agency, 1993; Barbash and Resek, 1996; Rupert, 1997). DRASTIC maps usually are not calibrated to measured contaminant concentrations. The DRASTIC ground-water vulnerability mapping method was improved by calibrating the point rating scheme to measured nitrite plus nitrate as nitrogen (NO2+NO3–N) concentrations in ground water on the basis of statistical correlations between NO2+NO3–N concentrations and land use, soils, and depth to water (Rupert, 1997). This report describes the calibration method developed by Rupert and summarizes the improvements in results of this method over those of the uncalibrated DRASTIC method applied by Rupert and others (1991) in the eastern Snake River Plain, Idaho.

  10. Characterization of biodegradation intermediates of nonionic surfactants by MALDI-MS. 2. Oxidative biodegradation profiles of uniform octylphenol polyethoxylate in 18O-labeled water.

    PubMed

    Sato, Hiroaki; Shibata, Atsushi; Wang, Yang; Yoshikawa, Hiromichi; Tamura, Hiroto

    2003-01-01

    This paper reports the characterization of the biodegradation intermediates of octylphenol octaethoxylate (OP(8)EO) by means of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). The biodegradation test study was carried out in a pure culture (Pseudomonas putida S-5) under aerobic conditions using OP(8)EO as the sole carbon source and (18)O-labeled water as an incubation medium. In the MALDI-MS spectra of biodegraded samples, a series of OP(n)EO molecules with n = 2-8 EO units and their corresponding carboxylic acid products (OP(n)EC) were observed. The use of purified OP(8)EO enabled one to distinguish the shortened OPEO molecules as biodegradation intermediates. Furthermore, the formation of OP(8)EC (the oxidized product of OP(8)EO) supported the notion that terminal oxidation is a step in the biodegradation process. When biodegradation study was carried out in (18)O-labeled water, incorporation of (18)O atoms into the carboxyl group was observed for OPEC, while no incorporation was observed for the shortened OPEO products. These results could provide some rationale to the biodegradation mechanism of alkylphenol polyethoxylates.

  11. Auxin Does Not Alter the Permeability of Pea Segments to Tritium-labeled Water.

    PubMed

    Dowler, M J; Rayle, D L

    1974-02-01

    The possibility of an auxin effect on the permeability of pea (Pisum sativum L. ev. Alaska) segments to tritium-labeled water has been investigated by three separate laboratories, and the combined results are presented. We were unable to obtain any indication of a rapid effect of indoleacetic acid on the efflux of (3)HHO when pea segments previously "loaded" for 90 minutes with (3)HHO were transferred to unlabeled aqueous medium with indoleacetic acid. We were able to confirm that segments pretreated with (3)HHO plus indoleacetic acid for 60 to 90 minutes can show an enhanced (3)HHO release as compared with minus indoleacetic acid controls. However, this phenomenon appears to be due to an increased uptake of (3)HHO during the prolonged indoleacetic acid pretreatment, and therefore we conclude that auxin does not alter the permeability of pea segments to (3)HHO in either short term or long term tests. We confirm previous reports that the uptake of (3)HHO in pea segments proceeds largely through the cut surfaces, and that the cuticle is a potent barrier to (3)HHO flux.

  12. Self-assessed performance improves statistical fusion of image labels

    PubMed Central

    Bryan, Frederick W.; Xu, Zhoubing; Asman, Andrew J.; Allen, Wade M.; Reich, Daniel S.; Landman, Bennett A.

    2014-01-01

    Purpose: Expert manual labeling is the gold standard for image segmentation, but this process is difficult, time-consuming, and prone to inter-individual differences. While fully automated methods have successfully targeted many anatomies, automated methods have not yet been developed for numerous essential structures (e.g., the internal structure of the spinal cord as seen on magnetic resonance imaging). Collaborative labeling is a new paradigm that offers a robust alternative that may realize both the throughput of automation and the guidance of experts. Yet, distributing manual labeling expertise across individuals and sites introduces potential human factors concerns (e.g., training, software usability) and statistical considerations (e.g., fusion of information, assessment of confidence, bias) that must be further explored. During the labeling process, it is simple to ask raters to self-assess the confidence of their labels, but this is rarely done and has not been previously quantitatively studied. Herein, the authors explore the utility of self-assessment in relation to automated assessment of rater performance in the context of statistical fusion. Methods: The authors conducted a study of 66 volumes manually labeled by 75 minimally trained human raters recruited from the university undergraduate population. Raters were given 15 min of training during which they were shown examples of correct segmentation, and the online segmentation tool was demonstrated. The volumes were labeled 2D slice-wise, and the slices were unordered. A self-assessed quality metric was produced by raters for each slice by marking a confidence bar superimposed on the slice. Volumes produced by both voting and statistical fusion algorithms were compared against a set of expert segmentations of the same volumes. Results: Labels for 8825 distinct slices were obtained. Simple majority voting resulted in statistically poorer performance than voting weighted by self-assessed performance

  13. 16 CFR Appendix L to Part 305 - Sample Labels

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... DISCLOSURES REGARDING ENERGY CONSUMPTION AND WATER USE OF CERTAIN HOME APPLIANCES AND OTHER PRODUCTS REQUIRED UNDER THE ENERGY POLICY AND CONSERVATION ACT (âAPPLIANCE LABELING RULEâ) Pt. 305, App. L Appendix L to...

  14. 16 CFR Appendix L to Part 305 - Sample Labels

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... DISCLOSURES REGARDING ENERGY CONSUMPTION AND WATER USE OF CERTAIN HOME APPLIANCES AND OTHER PRODUCTS REQUIRED UNDER THE ENERGY POLICY AND CONSERVATION ACT (âAPPLIANCE LABELING RULEâ) Pt. 305, App. L Appendix L to...

  15. 16 CFR Appendix L to Part 305 - Sample Labels

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... DISCLOSURES REGARDING ENERGY CONSUMPTION AND WATER USE OF CERTAIN HOME APPLIANCES AND OTHER PRODUCTS REQUIRED UNDER THE ENERGY POLICY AND CONSERVATION ACT (âAPPLIANCE LABELING RULEâ) Pt. 305, App. L Appendix L to...

  16. Method and kit for the selective labeling of red blood cells in whole blood with Tc-99m

    DOEpatents

    Srivastava, S.C.; Babich, J.W.; Straub, R.; Richards, P.

    1988-07-05

    Disclosed herein are a method and kit for the preparation of [sup 99m]Tc labeled red blood cells using whole blood in a closed sterile system containing stannous tin in a form such that it will enter the red blood cells and be available for the reduction of technetium. No Drawings

  17. OpenCL based machine learning labeling of biomedical datasets

    NASA Astrophysics Data System (ADS)

    Amoros, Oscar; Escalera, Sergio; Puig, Anna

    2011-03-01

    In this paper, we propose a two-stage labeling method of large biomedical datasets through a parallel approach in a single GPU. Diagnostic methods, structures volume measurements, and visualization systems are of major importance for surgery planning, intra-operative imaging and image-guided surgery. In all cases, to provide an automatic and interactive method to label or to tag different structures contained into input data becomes imperative. Several approaches to label or segment biomedical datasets has been proposed to discriminate different anatomical structures in an output tagged dataset. Among existing methods, supervised learning methods for segmentation have been devised to easily analyze biomedical datasets by a non-expert user. However, they still have some problems concerning practical application, such as slow learning and testing speeds. In addition, recent technological developments have led to widespread availability of multi-core CPUs and GPUs, as well as new software languages, such as NVIDIA's CUDA and OpenCL, allowing to apply parallel programming paradigms in conventional personal computers. Adaboost classifier is one of the most widely applied methods for labeling in the Machine Learning community. In a first stage, Adaboost trains a binary classifier from a set of pre-labeled samples described by a set of features. This binary classifier is defined as a weighted combination of weak classifiers. Each weak classifier is a simple decision function estimated on a single feature value. Then, at the testing stage, each weak classifier is independently applied on the features of a set of unlabeled samples. In this work, we propose an alternative representation of the Adaboost binary classifier. We use this proposed representation to define a new GPU-based parallelized Adaboost testing stage using OpenCL. We provide numerical experiments based on large available data sets and we compare our results to CPU-based strategies in terms of time and

  18. Rationale and evidence for menu-labeling legislation.

    PubMed

    Roberto, Christina A; Schwartz, Marlene B; Brownell, Kelly D

    2009-12-01

    Menu-labeling legislation is a proposed public health intervention for poor diet and obesity that requires chain restaurants to provide nutrition information on menus and menu boards. The restaurant industry has strongly opposed menu-labeling legislation. Using scientific evidence, this paper counters industry arguments against menu labeling by demonstrating that consumers want chain restaurant nutrition information to be disclosed; the current methods of providing nutrition information are inadequate; the expense of providing nutrition information is minimal; the government has the legal right to mandate disclosure of information; consumers have the right to know nutrition information; a lack of information reduces the efficiency of a market economy; and menu labeling has the potential to make a positive public health impact.

  19. Calibration of the DRASTIC ground water vulnerability mapping method

    USGS Publications Warehouse

    Rupert, M.G.

    2001-01-01

    Ground water vulnerability maps developed using the DRASTIC method have been produced in many parts of the world. Comparisons of those maps with actual ground water quality data have shown that the DRASTIC method is typically a poor predictor of ground water contamination. This study significantly improved the effectiveness of a modified DRASTIC ground water vulnerability map by calibrating the point rating schemes to actual ground water quality data by using nonparametric statistical techniques and a geographic information system. Calibration was performed by comparing data on nitrite plus nitrate as nitrogen (NO2 + NO3-N) concentrations in ground water to land-use, soils, and depth to first-encountered ground water data. These comparisons showed clear statistical differences between NO2 + NO3-N concentrations and the various categories. Ground water probability point ratings for NO2 + NO3-N contamination were developed from the results of these comparisons, and a probability map was produced. This ground water probability map was then correlated with an independent set of NO2 + NO3-N data to demonstrate its effectiveness in predicting elevated NO2 + NO3-N concentrations in ground water. This correlation demonstrated that the probability map was effective, but a vulnerability map produced with the uncalibrated DRASTIC method in the same area and using the same data layers was not effective. Considerable time and expense have been outlaid to develop ground water vulnerability maps with the DRASTIC method. This study demonstrates a cost-effective method to improve and verify the effectiveness of ground water vulnerability maps.

  20. Fluoride Content of Bottled Drinking Waters in Qatar.

    PubMed

    Almulla, Hessa Ibrahim; King, Nigel M; Alnsour, Hamza Mohammad; Sajnani, Anand K

    2016-12-01

    Fluoridation of drinking water has been recognized as one of the most effective ways of achieving community-wide exposure to the caries prevention effects of fluoride (F). A vast majority of people in Qatar use bottled water for drinking. Use of bottled water without knowing the F level may expose children to dental caries risk if the F level is lower than optimal or to dental fluorosis if the F level is too high. The aim of this study was to determine the F concentration of bottled water available in Qatar. A total of 32 brands of bottled water were evaluated. The F concentrations displayed on the labels were recorded. The F ion-selective electrode method was used to measure the F concentration in water samples, and three measurements were taken for every sample to ensure reproducibility. The p value was set at 0.05. The F concentration ranged from 0.06 to 3.0 ppm with a mean value of 0.8 ppm (±0.88). The F levels were provided by the manufacturers on the labels of 60 % of the samples, but this was significantly lower than the measured F levels (p < 0.0001). Moreover, bottled water that was produced in Saudi Arabia had significantly higher levels of F when compared to those produced in other countries (p < 0.05). There was a wide variation in the F levels in the different brands of bottled water. Furthermore, there was a significant disparity between the F levels which were measured and those that were provided on the labels.

  1. Advances in arterial spin labelling MRI methods for measuring perfusion and collateral flow.

    PubMed

    van Osch, Matthias Jp; Teeuwisse, Wouter M; Chen, Zhensen; Suzuki, Yuriko; Helle, Michael; Schmid, Sophie

    2017-01-01

    With the publication in 2015 of the consensus statement by the perfusion study group of the International Society for Magnetic Resonance in Medicine (ISMRM) and the EU-COST action 'ASL in dementia' on the implementation of arterial spin labelling MRI (ASL) in a clinical setting, the development of ASL can be considered to have become mature and ready for clinical prime-time. In this review article new developments and remaining issues will be discussed, especially focusing on quantification of ASL as well as on new technological developments of ASL for perfusion imaging and flow territory mapping. Uncertainty of the achieved labelling efficiency in pseudo-continuous ASL (pCASL) as well as the presence of arterial transit time artefacts, can be considered the main remaining challenges for the use of quantitative cerebral blood flow (CBF) values. New developments in ASL centre around time-efficient acquisition of dynamic ASL-images by means of time-encoded pCASL and diversification of information content, for example by combined 4D-angiography with perfusion imaging. Current vessel-encoded and super-selective pCASL-methodology have developed into easily applied flow-territory mapping methods providing relevant clinical information with highly similar information content as digital subtraction angiography (DSA), the current clinical standard. Both approaches seem therefore to be ready for clinical use.

  2. Water treatment: Chitosan associated with electrochemical methods

    NASA Astrophysics Data System (ADS)

    Tamiasso-Martinhon, Priscila; Marques Teixeira de Souza, João; Cruzeiro da Silva, Silvia Maria; Pellegrini Pessoa, Fernando Luiz; Sousa, Célia

    2017-04-01

    Pollution of water bodies due to the presence of toxic metals and organic compounds, bring out a series of environmental problems of public, government and social character. In addition, water pollution, has become the target and source of concern in many industrial sectors. Therefore, it is essential to develop technologies for treatment and purification of water. Chitosan is a natural product derived from chitin, extracted mainly from the shells of crustaceans. It is a low cost, renewable and biodegradable biopolymer of great socioeconomic and environmental importance. The classic treatment of wastewater containing metals involves physical chemistry processes of precipitation, ion exchange and electrochemistry. Electrochemical technology has been presented as the most promising methods for treating wastewater polluted with metals, colloids, dyes or oil in water emulsions; besides being used in removing organic compounds. Alternative methods like adsorption with biosorbents have been investigated. The great advantage of this latter over other techniques is the low generation of residues, easy recovery of metals and the possibility of reuse of the adsorbent. This article aimed to carry out an exploratory study, of bibliographical nature, on the use of chitosan in electrochemical methods for water treatment.

  3. Peptide-membrane Interactions by Spin-labeling EPR

    PubMed Central

    Smirnova, Tatyana I.; Smirnov, Alex I.

    2016-01-01

    Site-directed spin labeling (SDSL) in combination with Electron Paramagnetic Resonance (EPR) spectroscopy is a well-established method that has recently grown in popularity as an experimental technique, with multiple applications in protein and peptide science. The growth is driven by development of labeling strategies, as well as by considerable technical advances in the field, that are paralleled by an increased availability of EPR instrumentation. While the method requires an introduction of a paramagnetic probe at a well-defined position in a peptide sequence, it has been shown to be minimally destructive to the peptide structure and energetics of the peptide-membrane interactions. In this chapter, we describe basic approaches for using SDSL EPR spectroscopy to study interactions between small peptides and biological membranes or membrane mimetic systems. We focus on experimental approaches to quantify peptide-membrane binding, topology of bound peptides, and characterize peptide aggregation. Sample preparation protocols including spin-labeling methods and preparation of membrane mimetic systems are also described. PMID:26477253

  4. A general soft label based linear discriminant analysis for semi-supervised dimensionality reduction.

    PubMed

    Zhao, Mingbo; Zhang, Zhao; Chow, Tommy W S; Li, Bing

    2014-07-01

    Dealing with high-dimensional data has always been a major problem in research of pattern recognition and machine learning, and Linear Discriminant Analysis (LDA) is one of the most popular methods for dimension reduction. However, it only uses labeled samples while neglecting unlabeled samples, which are abundant and can be easily obtained in the real world. In this paper, we propose a new dimension reduction method, called "SL-LDA", by using unlabeled samples to enhance the performance of LDA. The new method first propagates label information from the labeled set to the unlabeled set via a label propagation process, where the predicted labels of unlabeled samples, called "soft labels", can be obtained. It then incorporates the soft labels into the construction of scatter matrixes to find a transformed matrix for dimension reduction. In this way, the proposed method can preserve more discriminative information, which is preferable when solving the classification problem. We further propose an efficient approach for solving SL-LDA under a least squares framework, and a flexible method of SL-LDA (FSL-LDA) to better cope with datasets sampled from a nonlinear manifold. Extensive simulations are carried out on several datasets, and the results show the effectiveness of the proposed method. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Label-enhanced surface plasmon resonance applied to label-free interaction analysis of small molecules and fragments.

    PubMed

    Eng, Lars; Nygren-Babol, Linnéa; Hanning, Anders

    2016-10-01

    Surface plasmon resonance (SPR) is a well-established method for studying interactions between small molecules and biomolecules. In particular, SPR is being increasingly applied within fragment-based drug discovery; however, within this application area, the limited sensitivity of SPR may constitute a problem. This problem can be circumvented by the use of label-enhanced SPR that shows a 100-fold higher sensitivity as compared with conventional SPR. Truly label-free interaction data for small molecules can be obtained by applying label-enhanced SPR in a surface competition assay format. The enhanced sensitivity is accompanied by an increased specificity and inertness toward disturbances (e.g., bulk refractive index disturbances). Label-enhanced SPR can be used for fragment screening in a competitive assay format; the competitive format has the added advantage of confirming the specificity of the molecular interaction. In addition, label-enhanced SPR extends the accessible kinetic regime of SPR to the analysis of very fast fragment binding kinetics. In this article, we demonstrate the working principles and benchmark the performance of label-enhanced SPR in a model system-the interaction between carbonic anhydrase II and a number of small-molecule sulfonamide-based inhibitors. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Pd-mediated rapid cross-couplings using [(11) C]methyl iodide: groundbreaking labeling methods in (11) C radiochemistry.

    PubMed

    Doi, Hisashi

    2015-03-01

    Prof. Bengt Långström is a pioneer in the field of chemistry-driven positron emission tomography (PET) imaging. He has developed a variety of excellent radiolabeling methodologies using the methods of organic chemistry, with the aim of widening the potential of PET in the study of life. Among his groundbreaking achievements in (11) C radiochemistry, there is the discovery of the Pd-mediated rapid cross-coupling reaction using [(11) C]methyl iodide. It was first reported by his Uppsala group in 1994-1995 and was further investigated by his and other groups with a view of enhancing its generality and practicability. This reaction is currently considered one of the basic methods for (11) C-labeling of low-weight organic compounds. This paper presents a short summary of the background and the development of Pd-mediated rapid cross-couplings of [(11) C]methyl iodide, with a focus not only on organostannanes, but also on organoboranes, organozincs, and terminal acetylene compounds. All these reactions have proven to be dependable (11) C-labeling methodologies that use chemically reliable carbon-carbon bond formation reactions. Copyright © 2015 John Wiley & Sons, Ltd.

  7. A comparison of methods for teaching receptive labeling to children with autism spectrum disorders: a systematic replication.

    PubMed

    Grow, Laura L; Kodak, Tiffany; Carr, James E

    2014-01-01

    Previous research has demonstrated that the conditional-only method (starting with a multiple-stimulus array) is more efficient than the simple-conditional method (progressive incorporation of more stimuli into the array) for teaching receptive labeling to children with autism spectrum disorders (Grow, Carr, Kodak, Jostad, & Kisamore,). The current study systematically replicated the earlier study by comparing the 2 approaches using progressive prompting with 2 boys with autism. The results showed that the conditional-only method was a more efficient and reliable teaching procedure than the simple-conditional method. The results further call into question the practice of teaching simple discriminations to facilitate acquisition of conditional discriminations. © Society for the Experimental Analysis of Behavior.

  8. Multilabel learning via random label selection for protein subcellular multilocations prediction.

    PubMed

    Wang, Xiao; Li, Guo-Zheng

    2013-01-01

    Prediction of protein subcellular localization is an important but challenging problem, particularly when proteins may simultaneously exist at, or move between, two or more different subcellular location sites. Most of the existing protein subcellular localization methods are only used to deal with the single-location proteins. In the past few years, only a few methods have been proposed to tackle proteins with multiple locations. However, they only adopt a simple strategy, that is, transforming the multilocation proteins to multiple proteins with single location, which does not take correlations among different subcellular locations into account. In this paper, a novel method named random label selection (RALS) (multilabel learning via RALS), which extends the simple binary relevance (BR) method, is proposed to learn from multilocation proteins in an effective and efficient way. RALS does not explicitly find the correlations among labels, but rather implicitly attempts to learn the label correlations from data by augmenting original feature space with randomly selected labels as its additional input features. Through the fivefold cross-validation test on a benchmark data set, we demonstrate our proposed method with consideration of label correlations obviously outperforms the baseline BR method without consideration of label correlations, indicating correlations among different subcellular locations really exist and contribute to improvement of prediction performance. Experimental results on two benchmark data sets also show that our proposed methods achieve significantly higher performance than some other state-of-the-art methods in predicting subcellular multilocations of proteins. The prediction web server is available at >http://levis.tongji.edu.cn:8080/bioinfo/MLPred-Euk/ for the public usage.

  9. A simple method for in vivo labelling of infiltrating leukocytes in the mouse retina using indocyanine green dye.

    PubMed

    Sim, Dawn A; Chu, Colin J; Selvam, Senthil; Powner, Michael B; Liyanage, Sidath; Copland, David A; Keane, Pearse A; Tufail, Adnan; Egan, Catherine A; Bainbridge, James W B; Lee, Richard W; Dick, Andrew D; Fruttiger, Marcus

    2015-11-01

    We have developed a method to label and image myeloid cells infiltrating the mouse retina and choroid in vivo, using a single depot injection of indocyanine green dye (ICG). This was demonstrated using the following ocular models of inflammation and angiogenesis: endotoxin-induced uveitis, experimental autoimmune uveoretinitis and laser-induced choroidal neovascularization model. A near-infrared scanning ophthalmoscope was used for in vivo imaging of the eye, and flow cytometry was used on blood and spleen to assess the number and phenotype of labelled cells. ICG was administered 72 h before the induction of inflammation to ensure clearance from the systemic circulation. We found that in vivo intravenous administration failed to label any leukocytes, whereas depot injection, either intraperitoneal or subcutaneous, was successful in labelling leukocytes infiltrating into the retina. Progression of inflammation in the retina could be traced over a period of 14 days following a single depot injection of ICG. Additionally, bright-field microscopy, spectrophotometry and flow cytometric analysis suggest that the predominant population of cells stained by ICG are circulating myeloid cells. The translation of this approach into clinical practice would enable visualization of immune cells in situ. This will not only provide a greater understanding of pathogenesis, monitoring and assessment of therapy in many human ocular diseases but might also open the ability to image immunity live for neurodegenerative disorders, cardiovascular disease and systemic immune-mediated disorders. © 2015. Published by The Company of Biologists Ltd.

  10. An algorithm for optimal fusion of atlases with different labeling protocols

    PubMed Central

    Iglesias, Juan Eugenio; Sabuncu, Mert Rory; Aganj, Iman; Bhatt, Priyanka; Casillas, Christen; Salat, David; Boxer, Adam; Fischl, Bruce; Van Leemput, Koen

    2014-01-01

    In this paper we present a novel label fusion algorithm suited for scenarios in which different manual delineation protocols with potentially disparate structures have been used to annotate the training scans (hereafter referred to as “atlases”). Such scenarios arise when atlases have missing structures, when they have been labeled with different levels of detail, or when they have been taken from different heterogeneous databases. The proposed algorithm can be used to automatically label a novel scan with any of the protocols from the training data. Further, it enables us to generate new labels that are not present in any delineation protocol by defining intersections on the underling labels. We first use probabilistic models of label fusion to generalize three popular label fusion techniques to the multi-protocol setting: majority voting, semi-locally weighted voting and STAPLE. Then, we identify some shortcomings of the generalized methods, namely the inability to produce meaningful posterior probabilities for the different labels (majority voting, semi-locally weighted voting) and to exploit the similarities between the atlases (all three methods). Finally, we propose a novel generative label fusion model that can overcome these drawbacks. We use the proposed method to combine four brain MRI datasets labeled with different protocols (with a total of 102 unique labeled structures) to produce segmentations of 148 brain regions. Using cross-validation, we show that the proposed algorithm outperforms the generalizations of majority voting, semi-locally weighted voting and STAPLE (mean Dice score 83%, vs. 77%, 80% and 79%, respectively). We also evaluated the proposed algorithm in an aging study, successfully reproducing some well-known results in cortical and subcortical structures. PMID:25463466

  11. Compositions and methods for removing arsenic in water

    DOEpatents

    Gadgil, Ashok Jagannth [El Cerrito, CA

    2011-02-22

    Compositions and methods and for contaminants from water are provided. The compositions comprise ferric hydroxide and ferric oxyhydride coated substrates for use in removing the contaminant from the water. Contacting water bearing the contaminant with the substrates can substantially reduce contaminant levels therein. Methods of oxidizing the contaminants in water to facilitate their removal by the ferric hydroxide and ferric oxyhydride coated substrates are also provided. The contaminants include, but are not limited to, arsenic, selenium, uranium, lead, cadmium, nickel, copper, zinc, chromium and vanadium, their oxides and soluble salts thereof.

  12. Join WaterSense

    EPA Pesticide Factsheets

    WaterSense depends on partners who make, sell, and promote WaterSense labeled products and homes, and certify irrigation pros. They also help educate consumers about water efficiency. Signing up is easy - and best of all, it's free!

  13. 99M-technetium labeled macroaggregated human serum albumin pharmaceutical

    DOEpatents

    Winchell, Harry S.; Barak, Morton; Van Fleet, III, Parmer

    1977-05-17

    A reagent comprising macroaggregated human serum albumin having dispersed therein particles of stannous tin and a method for instantly making a labeled pharmaceutical therefrom, are disclosed. The labeled pharmaceutical is utilized in organ imaging.

  14. Landscape Water Budget Tool

    EPA Pesticide Factsheets

    WaterSense created the Water Budget Tool as one option to help builders, landscape professionals, and irrigation professionals certified by a WaterSense labeled program meet the criteria specified in the WaterSense New Home Specification.

  15. Combination of diOlistic labeling with retrograde tract tracing and immunohistochemistry.

    PubMed

    Neely, M Diana; Stanwood, Gregg D; Deutch, Ariel Y

    2009-11-15

    Neuronal staining techniques have played a crucial role in the analysis of neuronal function. Several different staining techniques have been developed to allow morphological analyses of neurons. DiOlistic labeling, in which beads are coated with a lipophilic dye and then ballistically ejected onto brain tissue, has recently been introduced as a useful and simple means to label neurons and glia in their entirety. Although diOlistic labeling provides detailed information on the morphology of neurons, combining this approach with other staining methods is a significant advance. We have developed protocols that result in high quality diOlistically- and retrogradely-labeled or diOlistically-immunohistochemically labeled neurons. These dual-label methods require modification of fixation parameters and the restricted use of detergents for tissue permeabilization, and are readily applicable to a wide range of tracers and antibodies.

  16. Combination of DiOlistic Labeling with Retrograde Tract Tracing and Immunohistochemistry

    PubMed Central

    Diana Neely, M.; Stanwood, Gregg D; Deutch, Ariel Y.

    2009-01-01

    Neuronal staining techniques have played a crucial role in the analysis of neuronal function. Several different staining techniques have been developed to allow morphological analyses of neurons. Recently diOlistic labeling, in which beads are coated with a lipophilic dye and then ballistically ejected onto brain tissue, has been developed as a useful and simple means to label neurons and glia in their entirety. Although diOlistic labeling provides detailed information on the morphology of neurons, combining this approach with other staining methods is a significant advance. We have developed protocols that result in high quality diOlistically- and retrogradely-labeled or diOlistically-immunohistochemically labeled neurons. These dual-label methods require modification of fixation parameters and the use of detergents for tissue permeabilization, and are readily applicable to a wide range of tracers and antibodies. PMID:19712695

  17. Clean Water Act Analytical Methods

    EPA Pesticide Factsheets

    EPA publishes laboratory analytical methods (test procedures) that are used by industries and municipalities to analyze the chemical, physical and biological components of wastewater and other environmental samples required by the Clean Water Act.

  18. Food Labels

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español Food Labels KidsHealth / For Teens / Food Labels What's in ... to have at least 95% organic ingredients. Making Food Labels Work for You The first step in ...

  19. Bulk water phase and biofilm growth in drinking water at low nutrient conditions.

    PubMed

    Boe-Hansen, Rasmus; Albrechtsen, Hans-Jørgen; Arvin, Erik; Jørgensen, Claus

    2002-11-01

    In this study, the bacterial growth dynamics of a drinking water distribution system at low nutrient conditions was studied in order to determine bacterial growth rates by a range of methods, and to compare growth rates in the bulk water phase and the biofilm. A model distribution system was used to quantify the effect of retention times at hydraulic conditions similar to those in drinking water distribution networks. Water and pipe wall samples were taken and examined during the experiment. The pipes had been exposed to drinking water at approximately 13 degrees C, for at least 385 days to allow the formation of a mature quasi-stationary biofilm. At retention times of 12 h, total bacterial counts increased equivalent to a net bacterial growth rate of 0.048 day(-1). The bulk water phase bacteria exhibited a higher activity than the biofilm bacteria in terms of culturability, cell-specific ATP content, and cell-specific leucine incorporation rate. Bacteria in the bulk water phase incubated without the presence of biofilm exhibited a bacterial growth rate of 0.30 day(-1). The biofilm was radioactively labelled by the addition of 14C-benzoic acid. Subsequently, a biofilm detachment rate of 0.013 day(-1) was determined by measuring the release of 14C-labelled bacteria of the biofilm. For the quasi-stationary phase biofilm, the detachment rate was equivalent to the net growth rate. The growth rates determined in this study by different independent experimental approaches were comparable and within the range of values reported in the literature.

  20. Label Review Training: Module 1: Label Basics, Page 25

    EPA Pesticide Factsheets

    This module of the pesticide label review training provides basic information about pesticides, their labeling and regulation, and the core principles of pesticide label review: clarity, accuracy, consistency with EPA policy, and enforceability.

  1. Label Review Training: Module 1: Label Basics, Page 29

    EPA Pesticide Factsheets

    This module of the pesticide label review training provides basic information about pesticides, their labeling and regulation, and the core principles of pesticide label review. This page is a quiz on Module 1.

  2. 2D-IR Spectroscopy of an AHA Labeled Photoswitchable PDZ2 Domain.

    PubMed

    Stucki-Buchli, Brigitte; Johnson, Philip J M; Bozovic, Olga; Zanobini, Claudio; Koziol, Klemens L; Hamm, Peter; Gulzar, Adnan; Wolf, Steffen; Buchenberg, Sebastian; Stock, Gerhard

    2017-12-14

    We explore the capability of the non-natural amino acid azidohomoalanine (AHA) as an IR label to sense relatively small structural changes in proteins with the help of 2D IR difference spectroscopy. To that end, we AHA-labeled an allosteric protein (the PDZ2 domain from human tyrosine-phosphatase 1E) and furthermore covalently linked it to an azobenzene-derived photoswitch as to mimic its conformational transition upon ligand binding. To determine the strengths and limitations of the AHA label, in total six mutants have been investigated with the label at sites with varying properties. Only one mutant revealed a measurable 2D IR difference signal. In contrast to the commonly observed frequency shifts that report on the degree of solvation, in this case we observe an intensity change. To understand this spectral response, we performed classical MD simulations, evaluating local contacts of the AHA labels to water molecules and protein side chains and calculating the vibrational frequency on the basis of an electrostatic model. Although these simulations revealed in part significant and complex changes of the number of intraprotein and water contacts upon trans-cis photoisomerization, they could not provide a clear explanation of why this one label would stick out. Subsequent quantum-chemistry calculations suggest that the response is the result of an electronic interaction involving charge transfer of the azido group with sulfonate groups from the photoswitch. To the best of our knowledge, such an effect has not been described before.

  3. Labeled drawing of Jupiter showing its core and composition

    NASA Technical Reports Server (NTRS)

    1989-01-01

    Labeled drawing of Jupiter identifies fluid molecular hydrogen, transition zone, fluid metallic hydrogen, and possible core and the composition of its atmosphere - cloud tops - aerosols, ammonia crystals, ammonium hydrosulfide clouds, ice crystal clouds, and water droplets.

  4. Intercomparison of Lab-Based Soil Water Extraction Methods for Stable Water Isotope Analysis

    NASA Astrophysics Data System (ADS)

    Pratt, D.; Orlowski, N.; McDonnell, J.

    2016-12-01

    The effect of pore water extraction technique on resultant isotopic signature is poorly understood. Here we present results of an intercomparison of five common lab-based soil water extraction techniques: high pressure mechanical squeezing, centrifugation, direct vapor equilibration, microwave extraction, and cryogenic extraction. We applied five extraction methods to two physicochemically different standard soil types (silty sand and clayey loam) that were oven-dried and rewetted with water of known isotopic composition at three different gravimetric water contents (8, 20, and 30%). We tested the null hypothisis that all extraction techniques would provide the same isotopic result independent from soil type and water content. Our results showed that the extraction technique had a significant effect on the soil water isotopic composition. Each method exhibited deviations from spiked reference water, with soil type and water content showing a secondary effect. Cryogenic extraction showed the largest deviations from the reference water, whereas mechanical squeezing and centrifugation provided the closest match to the reference water for both soil types. We also compared results for each extraction technique that produced liquid water on both an OA-ICOS and IRMS; differences between them were negligible.

  5. Geophysical Methods for Investigating Ground-Water Recharge

    USGS Publications Warehouse

    Ferre, Ty P.A.; Binley, Andrew M.; Blasch, Kyle W.; Callegary, James B.; Crawford, Steven M.; Fink, James B.; Flint, Alan L.; Flint, Lorraine E.; Hoffmann, John P.; Izbicki, John A.; Levitt, Marc T.; Pool, Donald R.; Scanlon, Bridget R.

    2007-01-01

    While numerical modeling has revolutionized our understanding of basin-scale hydrologic processes, such models rely almost exclusively on traditional measurements?rainfall, streamflow, and water-table elevations?for calibration and testing. Model calibration provides initial estimates of ground-water recharge. Calibrated models are important yet crude tools for addressing questions about the spatial and temporal distribution of recharge. An inverse approach to recharge estimation is taken of necessity, due to inherent difficulties in making direct measurements of flow across the water table. Difficulties arise because recharging fluxes are typically small, even in humid regions, and because the location of the water table changes with time. Deep water tables in arid and semiarid regions make recharge monitoring especially difficult. Nevertheless, recharge monitoring must advance in order to improve assessments of ground-water recharge. Improved characterization of basin-scale recharge is critical for informed water-resources management. Difficulties in directly measuring recharge have prompted many efforts to develop indirect methods. The mass-balance approach of estimating recharge as the residual of generally much larger terms has persisted despite the use of increasing complex and finely gridded large-scale hydrologic models. Geophysical data pertaining to recharge rates, timing, and patterns have the potential to substantially improve modeling efforts by providing information on boundary conditions, by constraining model inputs, by testing simplifying assumptions, and by identifying the spatial and temporal resolutions needed to predict recharge to a specified tolerance in space and in time. Moreover, under certain conditions, geophysical measurements can yield direct estimates of recharge rates or changes in water storage, largely eliminating the need for indirect measures of recharge. This appendix presents an overview of physically based, geophysical methods

  6. Hydrophilic interaction liquid chromatography of anthranilic acid-labelled oligosaccharides with a 4-aminobenzoic acid ethyl ester-labelled dextran hydrolysate internal standard.

    PubMed

    Neville, David C A; Alonzi, Dominic S; Butters, Terry D

    2012-04-13

    Hydrophilic interaction liquid chromatography (HILIC) of fluorescently labelled oligosaccharides is used in many laboratories to analyse complex oligosaccharide mixtures. Separations are routinely performed using a TSK gel-Amide 80 HPLC column, and retention times of different oligosaccharide species are converted to glucose unit (GU) values that are determined with reference to an external standard. However, if retention times were to be compared with an internal standard, consistent and more accurate GU values would be obtained. We present a method to perform internal standard-calibrated HILIC of fluorescently labelled oligosaccharides. The method relies on co-injection of 4-aminobenzoic acid ethyl ester (4-ABEE)-labelled internal standard and detection by UV absorption, with 2-AA (2-aminobenzoic acid)-labelled oligosaccharides. 4-ABEE is a UV chromophore and a fluorophore, but there is no overlap of the fluorescent spectrum of 4-ABEE with the commonly used fluorescent reagents. The dual nature of 4-ABEE allows for accurate calculation of the delay between UV and fluorescent signals when determining the GU values of individual oligosaccharides. The GU values obtained are inherently more accurate as slight differences in gradients that can influence retention are negated by use of an internal standard. Therefore, this paper provides the first method for determination of HPLC-derived GU values of fluorescently labelled oligosaccharides using an internal calibrant. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Practical cell labeling with magnetite cationic liposomes for cell manipulation.

    PubMed

    Ito, Hiroshi; Nonogaki, Yurika; Kato, Ryuji; Honda, Hiroyuki

    2010-07-01

    Personalization of the cell culture process for cell therapy is an ideal strategy to obtain maximum treatment effects. In a previous report, we proposed a strategy using a magnetic manipulation device that combined a palm-top size device and a cell-labeling method using magnetite cationic liposomes (MCLs) to enable feasible personalized cell processing. In the present study, we focused on optimizing the MCL-labeling technique with respect to cell manipulation in small devices. From detailed analysis with different cell types, 4 pg/cell of MCL-label was found to be obtained immediately after mixing with MCLs, which was sufficient for magnetic cell manipulation. The amount of label increased within 24 h depending on cell type, although in all cases it decreased along with cell doubling, indicating that the labeling potential of MCLs was limited. The role of free MCLs not involved in labeling was also investigated; MCLs' role was found to be a supportive one that maximized the manipulation performance up to 100%. We also determined optimum conditions to manipulate adherent cells by MCL labeling using the MCL dispersed in trypsin solution. Considering labeling feasibility and practical performance with 10(3)-10(5) cells for personalized cell processing, we determined that 10 microg/ml of label without incubation time (0 h incubation) was the universal MCL-labeling condition. We propose the optimum specifications for a device to be combined with this method. 2010. Published by Elsevier B.V.

  8. Method for preparing radionuclide-labeled chelating agent-ligand complexes

    DOEpatents

    Meares, Claude F.; Li, Min; DeNardo, Sally J.

    1999-01-01

    Radionuclide-labeled chelating agent-ligand complexes that are useful in medical diagnosis or therapy are prepared by reacting a radionuclide, such as .sup.90 Y or .sup.111 In, with a polyfunctional chelating agent to form a radionuclide chelate that is electrically neutral; purifying the chelate by anion exchange chromatography; and reacting the purified chelate with a targeting molecule, such as a monoclonal antibody, to form the complex.

  9. High efficiency labeling of glycoproteins on living cells

    PubMed Central

    Zeng, Ying; Ramya, T. N. C.; Dirksen, Anouk; Dawson, Philip E.; Paulson, James C.

    2010-01-01

    We describe a simple method for efficiently labeling cell surface glycans on virtually any living animal cell. The method employs mild Periodate oxidation to generate an aldehyde on sialic acids, followed by Aniline-catalyzed oxime Ligation with a suitable tag (PAL). Aniline catalysis dramatically accelerates oxime ligation, allowing use of low concentrations of aminooxy-biotin at neutral pH to label the majority of cell surface glycoproteins while maintaining high cell viability. PMID:19234450

  10. Rapid synthesis of maleimide functionalized fluorine-18 labeled prosthetic group using "radio-fluorination on the Sep-Pak" method.

    PubMed

    Basuli, Falguni; Zhang, Xiang; Jagoda, Elaine M; Choyke, Peter L; Swenson, Rolf E

    2018-06-30

    Following our recently published fluorine-18 labeling method, "Radio-fluorination on the Sep-Pak", we have successfully synthesized 6-[ 18 F]fluoronicotinaldehyde by passing a solution (1:4 acetonitrile: t-butanol) of its quaternary ammonium salt precursor, 6-(N,N,N-trimethylamino)nicotinaldehyde trifluoromethanesulfonate (2), through a fluorine-18 containing anion exchange cartridge (PS-HCO 3 ). Over 80% radiochemical conversion was observed using 10 mg of precursor within 1 minute. The [ 18 F]fluoronicotinaldehyde ([ 18 F]5) was then conjugated with 1-(6-(aminooxy)hexyl)-1H-pyrrole-2,5-dione to prepare the fluorine-18 labeled maleimide functionalized prosthetic group, 6-[ 18 F]fluoronicotinaldehyde O-(6-(2,5-dioxo-2,5-dihydro-1H-pyrrol-1-yl)hexyl) oxime, 6-[ 18 F]FPyMHO ([ 18 F]6). The current Sep-Pak method not only improves the overall radiochemical yield (50 ± 9%, decay-corrected, n = 9) but also significantly reduces the synthesis time (from 60-90 minutes to 30 minutes) when compared with literature methods for the synthesis of similar prosthetic groups. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.

  11. Label-free density difference amplification-based cell sorting.

    PubMed

    Song, Jihwan; Song, Minsun; Kang, Taewook; Kim, Dongchoul; Lee, Luke P

    2014-11-01

    The selective cell separation is a critical step in fundamental life sciences, translational medicine, biotechnology, and energy harvesting. Conventional cell separation methods are fluorescent activated cell sorting and magnetic-activated cell sorting based on fluorescent probes and magnetic particles on cell surfaces. Label-free cell separation methods such as Raman-activated cell sorting, electro-physiologically activated cell sorting, dielectric-activated cell sorting, or inertial microfluidic cell sorting are, however, limited when separating cells of the same kind or cells with similar sizes and dielectric properties, as well as similar electrophysiological phenotypes. Here we report a label-free density difference amplification-based cell sorting (dDACS) without using any external optical, magnetic, electrical forces, or fluidic activations. The conceptual microfluidic design consists of an inlet, hydraulic jump cavity, and multiple outlets. Incoming particles experience gravity, buoyancy, and drag forces in the separation chamber. The height and distance that each particle can reach in the chamber are different and depend on its density, thus allowing for the separation of particles into multiple outlets. The separation behavior of the particles, based on the ratio of the channel heights of the inlet and chamber and Reynolds number has been systematically studied. Numerical simulation reveals that the difference between the heights of only lighter particles with densities close to that of water increases with increasing the ratio of the channel heights, while decreasing Reynolds number can amplify the difference in the heights between the particles considered irrespective of their densities.

  12. Automatic labeling of MR brain images through extensible learning and atlas forests.

    PubMed

    Xu, Lijun; Liu, Hong; Song, Enmin; Yan, Meng; Jin, Renchao; Hung, Chih-Cheng

    2017-12-01

    Multiatlas-based method is extensively used in MR brain images segmentation because of its simplicity and robustness. This method provides excellent accuracy although it is time consuming and limited in terms of obtaining information about new atlases. In this study, an automatic labeling of MR brain images through extensible learning and atlas forest is presented to address these limitations. We propose an extensible learning model which allows the multiatlas-based framework capable of managing the datasets with numerous atlases or dynamic atlas datasets and simultaneously ensure the accuracy of automatic labeling. Two new strategies are used to reduce the time and space complexity and improve the efficiency of the automatic labeling of brain MR images. First, atlases are encoded to atlas forests through random forest technology to reduce the time consumed for cross-registration between atlases and target image, and a scatter spatial vector is designed to eliminate errors caused by inaccurate registration. Second, an atlas selection method based on the extensible learning model is used to select atlases for target image without traversing the entire dataset and then obtain the accurate labeling. The labeling results of the proposed method were evaluated in three public datasets, namely, IBSR, LONI LPBA40, and ADNI. With the proposed method, the dice coefficient metric values on the three datasets were 84.17 ± 4.61%, 83.25 ± 4.29%, and 81.88 ± 4.53% which were 5% higher than those of the conventional method, respectively. The efficiency of the extensible learning model was evaluated by state-of-the-art methods for labeling of MR brain images. Experimental results showed that the proposed method could achieve accurate labeling for MR brain images without traversing the entire datasets. In the proposed multiatlas-based method, extensible learning and atlas forests were applied to control the automatic labeling of brain anatomies on large atlas datasets or dynamic

  13. Multi-atlas label fusion using hybrid of discriminative and generative classifiers for segmentation of cardiac MR images.

    PubMed

    Sedai, Suman; Garnavi, Rahil; Roy, Pallab; Xi Liang

    2015-08-01

    Multi-atlas segmentation first registers each atlas image to the target image and transfers the label of atlas image to the coordinate system of the target image. The transferred labels are then combined, using a label fusion algorithm. In this paper, we propose a novel label fusion method which aggregates discriminative learning and generative modeling for segmentation of cardiac MR images. First, a probabilistic Random Forest classifier is trained as a discriminative model to obtain the prior probability of a label at the given voxel of the target image. Then, a probability distribution of image patches is modeled using Gaussian Mixture Model for each label, providing the likelihood of the voxel belonging to the label. The final label posterior is obtained by combining the classification score and the likelihood score under Bayesian rule. Comparative study performed on MICCAI 2013 SATA Segmentation Challenge demonstrates that our proposed hybrid label fusion algorithm is accurate than other five state-of-the-art label fusion methods. The proposed method obtains dice similarity coefficient of 0.94 and 0.92 in segmenting epicardium and endocardium respectively. Moreover, our label fusion method achieves more accurate segmentation results compared to four other label fusion methods.

  14. Human neutrophil kinetics: modeling of stable isotope labeling data supports short blood neutrophil half-lives.

    PubMed

    Lahoz-Beneytez, Julio; Elemans, Marjet; Zhang, Yan; Ahmed, Raya; Salam, Arafa; Block, Michael; Niederalt, Christoph; Asquith, Becca; Macallan, Derek

    2016-06-30

    Human neutrophils have traditionally been thought to have a short half-life in blood; estimates vary from 4 to 18 hours. This dogma was recently challenged by stable isotope labeling studies with heavy water, which yielded estimates in excess of 3 days. To investigate this disparity, we generated new stable isotope labeling data in healthy adult subjects using both heavy water (n = 4) and deuterium-labeled glucose (n = 9), a compound with more rapid labeling kinetics. To interpret results, we developed a novel mechanistic model and applied it to previously published (n = 5) and newly generated data. We initially constrained the ratio of the blood neutrophil pool to the marrow precursor pool (ratio = 0.26; from published values). Analysis of heavy water data sets yielded turnover rates consistent with a short blood half-life, but parameters, particularly marrow transit time, were poorly defined. Analysis of glucose-labeling data yielded more precise estimates of half-life (0.79 ± 0.25 days; 19 hours) and marrow transit time (5.80 ± 0.42 days). Substitution of this marrow transit time in the heavy water analysis gave a better-defined blood half-life of 0.77 ± 0.14 days (18.5 hours), close to glucose-derived values. Allowing the ratio of blood neutrophils to mitotic neutrophil precursors (R) to vary yielded a best-fit value of 0.19. Reanalysis of the previously published model and data also revealed the origin of their long estimates for neutrophil half-life: an implicit assumption that R is very large, which is physiologically untenable. We conclude that stable isotope labeling in healthy humans is consistent with a blood neutrophil half-life of less than 1 day. © 2016 by The American Society of Hematology.

  15. Multi-label learning with fuzzy hypergraph regularization for protein subcellular location prediction.

    PubMed

    Chen, Jing; Tang, Yuan Yan; Chen, C L Philip; Fang, Bin; Lin, Yuewei; Shang, Zhaowei

    2014-12-01

    Protein subcellular location prediction aims to predict the location where a protein resides within a cell using computational methods. Considering the main limitations of the existing methods, we propose a hierarchical multi-label learning model FHML for both single-location proteins and multi-location proteins. The latent concepts are extracted through feature space decomposition and label space decomposition under the nonnegative data factorization framework. The extracted latent concepts are used as the codebook to indirectly connect the protein features to their annotations. We construct dual fuzzy hypergraphs to capture the intrinsic high-order relations embedded in not only feature space, but also label space. Finally, the subcellular location annotation information is propagated from the labeled proteins to the unlabeled proteins by performing dual fuzzy hypergraph Laplacian regularization. The experimental results on the six protein benchmark datasets demonstrate the superiority of our proposed method by comparing it with the state-of-the-art methods, and illustrate the benefit of exploiting both feature correlations and label correlations.

  16. A Novel Method for Assigning R, S Labels to Enantiomers.

    ERIC Educational Resources Information Center

    Huheey, James E.

    1986-01-01

    Discusses ways of teaching students about how to assign R (rectus) and S (sinister) labels to enantiomers by using their hands as models. The chirality of the human hands follows the Cahn-Ingold-Prelog Rules for assigning enantiomers and infers the correct chirality of molecules shown in two-dimensional drawings. (TW)

  17. Optimization and validation of a label-free MRM method for the quantification of cytochrome P450 isoforms in biological samples.

    PubMed

    Al Ali, Ahmad; Touboul, David; Le Caër, Jean-Pierre; Schmitz-Afonso, Isabelle; Flinois, Jean-Pierre; Marchetti, Catherine; De Waziers, Isabelle; Brunelle, Alain; Laprévote, Olivier; Beaune, Philippe

    2014-08-01

    Cytochromes P450 (CYPs) play critical roles in oxidative metabolism of many endogenous and exogenous compounds. Protein expression levels of CYPs in liver provide relevant information for a better understanding of the importance of CYPs in pharmacology and toxicology. This work aimed at establishing a simple method to quantify six CYPs (CYP3A4, CYP3A5, CYP1A2, CYP2D6, CYP2C9, and CYP2J2) in various biological samples without isotopic labeling. The biological matrix was spiked with the standard peptides prior to the digestion step to realize a label-free quantification by mass spectrometry. The method was validated and applied to quantify these six isoforms in both human liver microsomes and mitochondria, but also in recombinant expression systems such as baculosomes and the HepG2 cell line. The results showed intra-assay and interassay accuracy and precision within 16 % and 5 %, respectively, at the low quality control level, and demonstrated the advantages of the method in terms of reproducibility and cost.

  18. 78 FR 43974 - Energy and Water Use Labeling for Consumer Products Under the Energy Policy and Conservation Act...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-23

    ...The Commission amends the Energy Labeling Rule (``Rule'') by updating comparability ranges and unit energy costs for many EnergyGuide labels. The Commission also issues a conditional exemption and amendments for modified refrigerator and clothes washer labels to help consumers compare the labels for these products after the implementation of upcoming changes to the Department of Energy (``DOE'') test procedures.

  19. Less label, more free: approaches in label-free quantitative mass spectrometry.

    PubMed

    Neilson, Karlie A; Ali, Naveid A; Muralidharan, Sridevi; Mirzaei, Mehdi; Mariani, Michael; Assadourian, Gariné; Lee, Albert; van Sluyter, Steven C; Haynes, Paul A

    2011-02-01

    In this review we examine techniques, software, and statistical analyses used in label-free quantitative proteomics studies for area under the curve and spectral counting approaches. Recent advances in the field are discussed in an order that reflects a logical workflow design. Examples of studies that follow this design are presented to highlight the requirement for statistical assessment and further experiments to validate results from label-free quantitation. Limitations of label-free approaches are considered, label-free approaches are compared with labelling techniques, and forward-looking applications for label-free quantitative data are presented. We conclude that label-free quantitative proteomics is a reliable, versatile, and cost-effective alternative to labelled quantitation. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Methods of collecting and interpreting ground-water data

    USGS Publications Warehouse

    Bentall, Ray

    1963-01-01

    Because ground water is hidden from view, ancient man could only theorize as to its sources of replenishment and its behavior. His theories held sway until the latter part of the 17th century, which marked the first experimental work to determine the source and movement of ground water. Thus founded, the science of ground-water hydrology grew slowly and not until the 19th century is there substantial evidence of conclusions having been based on observational data. The 20th century has witnessed tremendous advances in the science in the methods of field investigation and interpretation of collected data, in the methods of determining the hydrologic characteristics of water-bearing material, and in the methods of inventorying ground-water supplies. Now, as is true of many other disciplines, the science of ground-water hydrology is characterized by frequent advancement of new ideas and techniques, refinement of old techniques, and an increasing wealth of data awaiting interpretation.So that its widely scattered staff of professional hydrologists could keep abreast of new ideas and advances in the techniques of groundwater investigation, it has been the practice in the U.S. Geological Survey to distribute such information for immediate internal use. As the methods become better established and developed, they are described in formal publications. Six papers pertaining to widely different phases of ground-water investigation comprise this particular contribution. For the sake of clarity and conformity, the original papers have been revised and edited by the compiler.

  1. Preparation of ⁶⁸Ga-labelled DOTA-peptides using a manual labelling approach for small-animal PET imaging.

    PubMed

    Romero, Eduardo; Martínez, Alfonso; Oteo, Marta; García, Angel; Morcillo, Miguel Angel

    2016-01-01

    (68)Ga-DOTA-peptides are a promising PET radiotracers used in the detection of different tumours types due to their ability for binding specifically receptors overexpressed in these. Furthermore, (68)Ga can be produced by a (68)Ge/(68)Ga generator on site which is a very good alternative to cyclotron-based PET isotopes. Here, we describe a manual labelling approach for the synthesis of (68)Ga-labelled DOTA-peptides based on concentration and purification of the commercial (68)Ga/(68)Ga generator eluate using an anion exchange-cartridge. (68)Ga-DOTA-TATE was used to image a pheochromocytoma xenograft mouse model by a microPET/CT scanner. The method described provides satisfactory results, allowing the subsequent (68)Ga use to label DOTA-peptides. The simplicity of the method along with its implementation reduced cost, makes it useful in preclinical PET studies. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Using DNA-labelled nano- and microparticles to track particle transport in the environment

    NASA Astrophysics Data System (ADS)

    McNew, Coy; Wang, Chaozi; Dahlke, Helen; Lyon, Steve; Walter, Todd

    2017-04-01

    By utilizing bio-molecular nanotechnology developed for nano-medicines and drug delivery, we are able to produce DNA-labelled nano- and microparticle tracers for use in a myriad of environmental systems. The use of custom sequenced DNA allows for the fabrication of an enormous number of uniquely labelled tracers with identical transport properties (approximately 1.61 x 1060 unique sequences), each independently quantifiable, that can be applied simultaneously in any hydrologic system. By controlling the fabrication procedure to produce particles of custom size and charge, we are able to tag each size-charge combination uniquely in order to directly probe the effect of these variables on the transport properties of the particles. Here we present our methods for fabrication, extraction, and analysis of the DNA nano- and microparticle tracers, along with results from several successful applications of the tracers, including transport and retention analysis at the lab, continuum, and field scales. To date, our DNA-labelled nano- and microparticle tracers have proved useful in surface and subsurface water applications, soil retention, and even subglacial flow pathways. The range of potential applications continue to prove nearly limitless.

  3. Thermal Methods for Investigating Ground-Water Recharge

    USGS Publications Warehouse

    Blasch, Kyle W.; Constantz, Jim; Stonestrom, David A.

    2007-01-01

    Recharge of aquifers within arid and semiarid environments is defined as the downward flux of water across the regional water table. The introduction of recharging water at the land surface can occur at discreet locations, such as in stream channels, or be distributed over the landscape, such as across broad interarroyo areas within an alluvial ground-water basin. The occurrence of recharge at discreet locations is referred to as focused recharge, whereas the occurrence of recharge over broad regions is referred to as diffuse recharge. The primary interest of this appendix is focused recharge, but regardless of the type of recharge, estimation of downward fluxes is essential to its quantification. Like chemical tracers, heat can come from natural sources or be intentionally introduced to infer transport properties and aquifer recharge. The admission and redistribution of heat from natural processes such as insolation, infiltration, and geothermal activity can be used to quantify subsurface flow regimes. Heat is well suited as a ground-water tracer because it provides a naturally present dynamic signal and is relatively harmless over a useful range of induced perturbations. Thermal methods have proven valuable for recharge investigations for several reasons. First, theoretical descriptions of coupled water-and-heat transport are available for the hydrologic processes most often encountered in practice. These include land-surface mechanisms such as radiant heating from the sun, radiant cooling into space, and evapotranspiration, in addition to the advective and conductive mechanisms that usually dominate at depth. Second, temperature is theoretically well defined and readily measured. Third, thermal methods for depths ranging from the land surface to depths of hundreds of meters are based on similar physical principles. Fourth, numerical codes for simulating heat and water transport have become increasingly reliable and widely available. Direct measurement of water

  4. 40 CFR 600.115-08 - Criteria for determining the fuel economy label calculation method for 2011 and later model year...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... economy label calculation method for 2011 and later model year vehicles. 600.115-08 Section 600.115-08 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND CARBON-RELATED EXHAUST EMISSIONS OF MOTOR VEHICLES Fuel Economy and Carbon-Related Exhaust Emission Regulations...

  5. Efficient assimilation of cyanobacterial nitrogen by water hyacinth.

    PubMed

    Qin, Hongjie; Zhang, Zhiyong; Liu, Minhui; Wang, Yan; Wen, Xuezheng; Yan, Shaohua; Zhang, Yingying; Liu, Haiqin

    2017-10-01

    A 15 N labeling technique was used to study nitrogen transfer from cyanobacterium Microcystis aeruginosa to water hyacinth. 15 N atom abundance in M. aeruginosa peaked (15.52%) after cultivation in 15 N-labeled medium for 3weeks. Over 87% of algal nitrogen was transferred into water hyacinth after the 4-week co-cultivation period. The nitrogen quickly super-accumulated in the water hyacinth roots, and the labeled nitrogen was re-distributed to different organs (i.e., roots, stalks, and leaves). This study provides a new strategy for further research on cyanobacterial bloom control, nitrogen migration, and nitrogen cycle in eutrophic waters. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Water uptake of Alaskan tundra evergreens during the winter-spring transition.

    PubMed

    Moser, Jonathan G; Oberbauer, Steven F; Sternberg, Leonel da S L; Ellsworth, Patrick Z; Starr, Gregory; Mortazavi, Behzad; Olivas, Paulo C

    2016-02-01

    The cold season in the Arctic extends over 8 to 9 mo, yet little is known about vascular plant physiology during this period. Evergreen species photosynthesize under the snow, implying that they are exchanging water with the atmosphere. However, liquid water available for plant uptake may be limited at this time. The study objective was to determine whether evergreen plants are actively taking up water while under snow and/or immediately following snowmelt during spring thaw. In two in situ experiments, one at the plot level and another at the individual species level, (2)H-labeled water was used as a tracer injected beneath the snow, after which plant stems and leaves were tested for the presence of the label. In separate experiments, excised shoots of evergreen species were exposed to (2)H-labeled water for ∼5 s or 60 min and tested for foliar uptake of the label. In both the plot-level and the species-level experiments, some (2)H-labeled water was found in leaves and stems. Additionally, excised individual plant shoots exposed to labeled water for 60 min took up significantly more (2)H-label than shoots exposed ∼5 s. Evergreen tundra plants take up water under snow cover, some via roots, but also likely by foliar uptake. The ability to take up water in the subnivean environment allows evergreen tundra plants to take advantage of mild spring conditions under the snow and replenish carbon lost by winter respiration. © 2016 Botanical Society of America.

  7. Production of stable isotope-labeled acyl-coenzyme A thioesters by yeast stable isotope labeling by essential nutrients in cell culture

    PubMed Central

    Snyder, Nathaniel W.; Tombline, Gregory; Worth, Andrew J.; Parry, Robert C.; Silvers, Jacob A.; Gillespie, Kevin P.; Basu, Sankha S.; Millen, Jonathan; Goldfarb, David S.; Blair, Ian A.

    2015-01-01

    Acyl-coenzyme A (CoA) thioesters are key metabolites in numerous anabolic and catabolic pathways, including fatty acid biosynthesis and β-oxidation, the Krebs cycle, and cholesterol and isoprenoid biosynthesis. Stable isotope dilution-based methodology is the gold standard for quantitative analyses by mass spectrometry. However, chemical synthesis of families of stable isotope labeled metabolites such as acyl-coenzyme A thioesters is impractical. Previously, we biosynthetically generated a library of stable isotope internal standard analogs of acyl-CoA thioesters by exploiting the essential requirement in mammals and insects for pantothenic acid (vitamin B5) as a metabolic precursor for the CoA backbone. By replacing pantothenic acid in the cell media with commercially available [13C3 15N1]-pantothenic acid, mammalian cells exclusively incorporated [13C3 15N1]-pantothenate into the biosynthesis of acyl-CoA and acyl-CoA thioesters. We have now developed a much more efficient method for generating stable isotope labeled CoA and acyl-CoAs from [13C3 15N1]-pantothenate using Stable Isotope Labeling by Essential nutrients in Cell culture (SILEC) in Pan6 deficient yeast cells. Efficiency and consistency of labeling were also increased, likely due to the stringently defined and reproducible conditions used for yeast culture. The yeast SILEC method greatly enhances the ease of use and accessibility of labeled CoA thioesters and also provides proof-of-concept for generating other labeled metabolites in yeast mutants. PMID:25572876

  8. A simple method to determine mineralization of (14) C-labeled compounds in soil.

    PubMed

    Myung, Kyung; Madary, Michael W; Satchivi, Norbert M

    2014-06-01

    Degradation of organic compounds in soil is often determined by measuring the decrease of the parent compound and analyzing the occurrence of its metabolites. However, determining carbon species as end products of parent compound dissipation requires using labeled materials that allow more accurate determination of the environmental fate of the compound of interest. The current conventional closed system widely used to monitor degradation of (14) C-labeled compounds in soil is complex and expensive and requires a specialized apparatus and facility. In the present study, the authors describe a simple system that facilitates measurement of mineralization of (14) C-labeled compounds applied to soil samples. In the system, soda lime pellets to trap mineralized (14) C-carbon species, including carbon dioxide, were placed in a cup, which was then inserted above the treated soil sample in a tube. Mineralization of [(14) C]2,4-D applied to soil samples in the simple system was compared with that in the conventional system. The simple system provided an equivalent detection of (14) C-carbon species mineralized from the parent compound. The results demonstrate that this cost- and space-effective simple system is suitable for examining degradation and mineralization of (14) C-labeled compounds in soil and could potentially be used to investigate their mineralization in other biological matrices. © 2014 SETAC.

  9. Significant body point labeling and tracking.

    PubMed

    Azhar, Faisal; Tjahjadi, Tardi

    2014-09-01

    In this paper, a method is presented to label and track anatomical landmarks (e.g., head, hand/arm, feet), which are referred to as significant body points (SBPs), using implicit body models. By considering the human body as an inverted pendulum model, ellipse fitting and contour moments are applied to classify it as being in Stand, Sit, or Lie posture. A convex hull of the silhouette contour is used to determine the locations of SBPs. The particle filter or a motion flow-based method is used to predict SBPs in occlusion. Stick figures of various activities are generated by connecting the SBPs. The qualitative and quantitative evaluation show that the proposed method robustly labels and tracks SBPs in various activities of two different (low and high) resolution data sets.

  10. Manifold regularized matrix completion for multi-label learning with ADMM.

    PubMed

    Liu, Bin; Li, Yingming; Xu, Zenglin

    2018-05-01

    Multi-label learning is a common machine learning problem arising from numerous real-world applications in diverse fields, e.g, natural language processing, bioinformatics, information retrieval and so on. Among various multi-label learning methods, the matrix completion approach has been regarded as a promising approach to transductive multi-label learning. By constructing a joint matrix comprising the feature matrix and the label matrix, the missing labels of test samples are regarded as missing values of the joint matrix. With the low-rank assumption of the constructed joint matrix, the missing labels can be recovered by minimizing its rank. Despite its success, most matrix completion based approaches ignore the smoothness assumption of unlabeled data, i.e., neighboring instances should also share a similar set of labels. Thus they may under exploit the intrinsic structures of data. In addition, the matrix completion problem can be less efficient. To this end, we propose to efficiently solve the multi-label learning problem as an enhanced matrix completion model with manifold regularization, where the graph Laplacian is used to ensure the label smoothness over it. To speed up the convergence of our model, we develop an efficient iterative algorithm, which solves the resulted nuclear norm minimization problem with the alternating direction method of multipliers (ADMM). Experiments on both synthetic and real-world data have shown the promising results of the proposed approach. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. 101 Labeled Brain Images and a Consistent Human Cortical Labeling Protocol

    PubMed Central

    Klein, Arno; Tourville, Jason

    2012-01-01

    We introduce the Mindboggle-101 dataset, the largest and most complete set of free, publicly accessible, manually labeled human brain images. To manually label the macroscopic anatomy in magnetic resonance images of 101 healthy participants, we created a new cortical labeling protocol that relies on robust anatomical landmarks and minimal manual edits after initialization with automated labels. The “Desikan–Killiany–Tourville” (DKT) protocol is intended to improve the ease, consistency, and accuracy of labeling human cortical areas. Given how difficult it is to label brains, the Mindboggle-101 dataset is intended to serve as brain atlases for use in labeling other brains, as a normative dataset to establish morphometric variation in a healthy population for comparison against clinical populations, and contribute to the development, training, testing, and evaluation of automated registration and labeling algorithms. To this end, we also introduce benchmarks for the evaluation of such algorithms by comparing our manual labels with labels automatically generated by probabilistic and multi-atlas registration-based approaches. All data and related software and updated information are available on the http://mindboggle.info/data website. PMID:23227001

  12. Rapid label-free identification of Klebsiella pneumoniae antibiotic resistant strains by the drop-coating deposition surface-enhanced Raman scattering method

    NASA Astrophysics Data System (ADS)

    Cheong, Youjin; Kim, Young Jin; Kang, Heeyoon; Choi, Samjin; Lee, Hee Joo

    2017-08-01

    Although many methodologies have been developed to identify unknown bacteria, bacterial identification in clinical microbiology remains a complex and time-consuming procedure. To address this problem, we developed a label-free method for rapidly identifying clinically relevant multilocus sequencing typing-verified quinolone-resistant Klebsiella pneumoniae strains. We also applied the method to identify three strains from colony samples, ATCC70063 (control), ST11 and ST15; these are the prevalent quinolone-resistant K. pneumoniae strains in East Asia. The colonies were identified using a drop-coating deposition surface-enhanced Raman scattering (DCD-SERS) procedure coupled with a multivariate statistical method. Our workflow exhibited an enhancement factor of 11.3 × 106 to Raman intensities, high reproducibility (relative standard deviation of 7.4%), and a sensitive limit of detection (100 pM rhodamine 6G), with a correlation coefficient of 0.98. All quinolone-resistant K. pneumoniae strains showed similar spectral Raman shifts (high correlations) regardless of bacterial type, as well as different Raman vibrational modes compared to Escherichia coli strains. Our proposed DCD-SERS procedure coupled with the multivariate statistics-based identification method achieved excellent performance in discriminating similar microbes from one another and also in subtyping of K. pneumoniae strains. Therefore, our label-free DCD-SERS procedure coupled with the computational decision supporting method is a potentially useful method for the rapid identification of clinically relevant K. pneumoniae strains.

  13. Under-reporting of food intake is frequent among Brazilian free-living older persons: a doubly labelled water study.

    PubMed

    Ferriolli, Eduardo; Pfrimer, Karina; Moriguti, Julio C; Lima, Nereida K C; Moriguti, Eny K U; Formighieri, Paulo F; Scagliusi, Fernanda B; Marchini, Julio S

    2010-03-15

    The assessment of food intake is essential for the development of dietetic interventions. Accuracy is low when intake is assessed by questionnaires, the under-reporting of food intake being frequent. Most such studies, however, were performed in developed countries and there is little data about the older population of developing nations. This study aimed to verify the total energy expenditure (TEE) of independent older Brazilians living in an urban area, through the doubly labelled water (DLW) method and to compare it with the reported energy intake obtained through the application of a food frequency questionnaire (FFQ). Initially, 100 volunteers aged from 60 to 75 years had their body composition determined by dual-energy X-ray absorptiometry (DEXA). Five volunteers of each quartile of body fat percentage had their energy expenditure determined by DLW. The mean age of the subjects included in this phase of the study was 66.4 +/- 3.5 years, and ten of the subjects were men. The mean TEE was 2565 +/- 614 and 2154 +/- 339 kcal.day(-1) for men and women, respectively. The Physical Activity Level (PAL) was 1.58 +/- 0.31 and 1.52 +/- 0.22, respectively. Under-reporting of food intake was highly prevalent, with a mean percentage of reported intake in relation to measured TEE of -17.7%. Thus, under-reporting of food intake is highly prevalent among Brazilian independent older persons. The DLW method is an important tool in nutritional studies and its use is to be recommended in developing countries. Copyright 2010 John Wiley & Sons, Ltd.

  14. Synthesis, photophysical properties and application of dye doped water soluble silica-based nanoparticles to label bacteria E. coli O157:H7

    NASA Astrophysics Data System (ADS)

    Tan Pham, Minh; Van Nguyen, Thi; Thi, Thuy Duong Vu; Nghiem Thi, Ha Lien; Thuan Tong, Kim; Thuy Tran, Thanh; Chu, Viet Ha; Brochon, Jean-Claude; Nhung Tran, Hong

    2012-12-01

    Organically modified silicate (ORMOSIL) nanoparticles (NPs) doped with rhodamine 6G and rhodamine B (RB) dyes were synthesized by Stöber method from methyltriethoxysilane CH3Si(OCH3)3 precursor (MTEOS). The NPs are surface functionalized by cationic amino groups. The optical characterization of dye-doped ORMOSIL NPs was studied in comparison with that of free dye in solution. The synthesized NPs were used for labeling bacteria E. coli O157:H7. The number of bacteria have been counted using the fluorescent spectra and microscope images of labeled bacteria. The results show the ability of NPs to work as biomarkers.

  15. Topics in Library Technology: Labeling Techniques *

    PubMed Central

    Truelson, Stanley D.

    1966-01-01

    Labels which do not fit on the spines of books should be placed on the upper rather than lower left corner of the front cover, because the upper corner becomes visible first when a volume is tilted from the shelf. None of the past methods of marking call numbers on the spines or covers of books—direct hand lettering by pen, brush, or stylus; affixing cold release characters; embossing by hot type; or gluing labels which are handlettered, typed, or printed—nor even present automatic data processing systems have offered all the advantages of the relatively new Se-Lin labeling system: legibility, reasonable speed of application, automatic protective covering, permanent bonding, and no need for a skilled letterer. Labels seem unaesthetic to some librarians, but their advantages outweigh this consideration. When only one or a few copies of the same call number are required, Se-Lin is the best system now available for libraries marking over 1,000 books a year. PMID:5901359

  16. Preliminary research on quantitative methods of water resources carrying capacity based on water resources balance sheet

    NASA Astrophysics Data System (ADS)

    Wang, Yanqiu; Huang, Xiaorong; Gao, Linyun; Guo, Biying; Ma, Kai

    2018-06-01

    Water resources are not only basic natural resources, but also strategic economic resources and ecological control factors. Water resources carrying capacity constrains the sustainable development of regional economy and society. Studies of water resources carrying capacity can provide helpful information about how the socioeconomic system is both supported and restrained by the water resources system. Based on the research of different scholars, major problems in the study of water resources carrying capacity were summarized as follows: the definition of water resources carrying capacity is not yet unified; the methods of carrying capacity quantification based on the definition of inconsistency are poor in operability; the current quantitative research methods of water resources carrying capacity did not fully reflect the principles of sustainable development; it is difficult to quantify the relationship among the water resources, economic society and ecological environment. Therefore, it is necessary to develop a better quantitative evaluation method to determine the regional water resources carrying capacity. This paper proposes a new approach to quantifying water resources carrying capacity (that is, through the compilation of the water resources balance sheet) to get a grasp of the regional water resources depletion and water environmental degradation (as well as regional water resources stock assets and liabilities), figure out the squeeze of socioeconomic activities on the environment, and discuss the quantitative calculation methods and technical route of water resources carrying capacity which are able to embody the substance of sustainable development.

  17. 46 CFR 160.058-5 - Labeling and marking.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 6 2013-10-01 2013-10-01 false Labeling and marking. 160.058-5 Section 160.058-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Desalter Kits, Sea Water, for Merchant Vessels § 160.058-5...

  18. 46 CFR 160.058-5 - Labeling and marking.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 6 2012-10-01 2012-10-01 false Labeling and marking. 160.058-5 Section 160.058-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Desalter Kits, Sea Water, for Merchant Vessels § 160.058-5...

  19. 46 CFR 160.058-5 - Labeling and marking.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 6 2014-10-01 2014-10-01 false Labeling and marking. 160.058-5 Section 160.058-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Desalter Kits, Sea Water, for Merchant Vessels § 160.058-5...

  20. 46 CFR 160.058-5 - Labeling and marking.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Labeling and marking. 160.058-5 Section 160.058-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Desalter Kits, Sea Water, for Merchant Vessels § 160.058-5...

  1. 46 CFR 160.058-5 - Labeling and marking.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Labeling and marking. 160.058-5 Section 160.058-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Desalter Kits, Sea Water, for Merchant Vessels § 160.058-5...

  2. Using the Method of Water Poverty Index (WPI) to Evaluate the Region Water Security

    NASA Astrophysics Data System (ADS)

    Fu, Q.; Kachanoski, G.

    2008-12-01

    Water security is a widely concerned issue in the world nowadays. A new method, water poverty index (WPI), has been used to evaluate the regional water security. Twelve state farms in Heilongjiang Province, Northeastern China were selected to evaluate water security status based on the data of 2006 by using WPI and mean deviation grading method. The method of WPI includes five key indexes, such as resources(R), access (A), capacity(C), utilization (U) and environment (E). Each key index includes several sub-indexes. According to the results of WPI, the grade of each farm has been calculated by using the method of mean deviation grading. Thus, the radar images can be protracted of each farm. From the radar images, the conclusions can be drawn that the WPI values of Farms 853 and Hongqiling were in very safe status, while that of Farm Raohe was in safe status, those of Farms Youyi, 597, 852, 291 and Jiangchuan were in moderate safe status, that of Farm Beixing was in low safe status and those of Farms Shuangyashan, Shuguang and Baoshan were in unsafe status. The results from this study can provide basic information for decision making on rational use of water resources and regulations for regional water safety guarantee system.

  3. A new method for water quality assessment: by harmony degree equation.

    PubMed

    Zuo, Qiting; Han, Chunhui; Liu, Jing; Ma, Junxia

    2018-02-22

    Water quality assessment is an important basic work in the development, utilization, management, and protection of water resources, and also a prerequisite for water safety. In this paper, the harmony degree equation (HDE) was introduced into the research of water quality assessment, and a new method for water quality assessment was proposed according to the HDE: by harmony degree equation (WQA-HDE). First of all, the calculation steps and ideas of this method were described in detail, and then, this method with some other important methods of water quality assessment (single factor assessment method, mean-type comprehensive index assessment method, and multi-level gray correlation assessment method) were used to assess the water quality of the Shaying River (the largest tributary of the Huaihe in China). For this purpose, 2 years (2013-2014) dataset of nine water quality variables covering seven monitoring sites, and approximately 189 observations were used to compare and analyze the characteristics and advantages of the new method. The results showed that the calculation steps of WQA-HDE are similar to the comprehensive assessment method, and WQA-HDE is more operational comparing with the results of other water quality assessment methods. In addition, this new method shows good flexibility by setting the judgment criteria value HD 0 of water quality; when HD 0  = 0.8, the results are closer to reality, and more realistic and reliable. Particularly, when HD 0  = 1, the results of WQA-HDE are consistent with the single factor assessment method, both methods are subject to the most stringent "one vote veto" judgment condition. So, WQA-HDE is a composite method that combines the single factor assessment and comprehensive assessment. This research not only broadens the research field of theoretical method system of harmony theory but also promotes the unity of water quality assessment method and can be used for reference in other comprehensive assessment.

  4. Do nutrition labels influence healthier food choices? Analysis of label viewing behaviour and subsequent food purchases in a labelling intervention trial.

    PubMed

    Ni Mhurchu, Cliona; Eyles, Helen; Jiang, Yannan; Blakely, Tony

    2018-02-01

    There are few objective data on how nutrition labels are used in real-world shopping situations, or how they affect dietary choices and patterns. The Starlight study was a four-week randomised, controlled trial of the effects of three different types of nutrition labels on consumer food purchases: Traffic Light Labels, Health Star Rating labels, or Nutrition Information Panels (control). Smartphone technology allowed participants to scan barcodes of packaged foods and receive randomly allocated labels on their phone screen, and to record their food purchases. The study app therefore provided objectively recorded data on label viewing behaviour and food purchases over a four-week period. A post-hoc analysis of trial data was undertaken to assess frequency of label use, label use by food group, and association between label use and the healthiness of packaged food products purchased. Over the four-week intervention, study participants (n = 1255) viewed nutrition labels for and/or purchased 66,915 barcoded packaged products. Labels were viewed for 23% of all purchased products, with decreasing frequency over time. Shoppers were most likely to view labels for convenience foods, cereals, snack foods, bread and bakery products, and oils. They were least likely to view labels for sugar and honey products, eggs, fish, fruit and vegetables, and meat. Products for which participants viewed the label and subsequently purchased the product during the same shopping episode were significantly healthier than products where labels were viewed but the product was not subsequently purchased: mean difference in nutrient profile score -0.90 (95% CI -1.54 to -0.26). In a secondary analysis of a nutrition labelling intervention trial, there was a significant association between label use and the healthiness of products purchased. Nutrition label use may therefore lead to healthier food purchases. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. Label-free resistive-pulse cytometry.

    PubMed

    Chapman, M R; Sohn, L L

    2011-01-01

    Numerous methods have recently been developed to characterize cells for size, shape, and specific cell-surface markers. Most of these methods rely upon exogenous labeling of the cells and are better suited for large cell populations (>10,000). Here, we review a label-free method of characterizing and screening cells based on the Coulter-counter technique of particle sizing: an individual cell transiting a microchannel (or "pore") causes a downward pulse in the measured DC current across that "pore". Pulse magnitude corresponds to the cell size, pulse width to the transit time needed for the cell to pass through the pore, and pulse shape to how the cell traverses across the pore (i.e., rolling or tumbling). When the pore is functionalized with an antibody that is specific to a surface-epitope of interest, label-free screening of a specific marker is possible, as transient binding between the two results in longer time duration than when the pore is unfunctionalized or functionalized with a nonspecific antibody. While this method cannot currently compete with traditional technology in terms of throughput, there are a number of applications for which this technology is better suited than current commercial cytometry systems. Applications include the rapid and nondestructive analysis of small cell populations (<100), which is not possible with current technology, and a platform for providing true point-of-care clinical diagnostics, due to the simplicity of the device, low manufacturing costs, and ease of use. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Comparing the Ability of Enhanced Sampling Molecular Dynamics Methods To Reproduce the Behavior of Fluorescent Labels on Proteins.

    PubMed

    Walczewska-Szewc, Katarzyna; Deplazes, Evelyne; Corry, Ben

    2015-07-14

    Adequately sampling the large number of conformations accessible to proteins and other macromolecules is one of the central challenges in molecular dynamics (MD) simulations; this activity can be difficult, even for relatively simple systems. An example where this problem arises is in the simulation of dye-labeled proteins, which are now being widely used in the design and interpretation of Förster resonance energy transfer (FRET) experiments. In this study, MD simulations are used to characterize the motion of two commonly used FRET dyes attached to an immobilized chain of polyproline. Even in this simple system, the dyes exhibit complex behavior that is a mixture of fast and slow motions. Consequently, very long MD simulations are required to sufficiently sample the entire range of dye motion. Here, we compare the ability of enhanced sampling methods to reproduce the behavior of fluorescent labels on proteins. In particular, we compared Accelerated Molecular Dynamics (AMD), metadynamics, Replica Exchange Molecular Dynamics (REMD), and High Temperature Molecular Dynamics (HTMD) to equilibrium MD simulations. We find that, in our system, all of these methods improve the sampling of the dye motion, but the most significant improvement is achieved using REMD.

  7. Evaluating the Impact of Menu Labeling on Food Choices and Intake

    PubMed Central

    Larsen, Peter D.; Agnew, Henry; Baik, Jenny; Brownell, Kelly D.

    2010-01-01

    Objectives. We assessed the impact of restaurant menu calorie labels on food choices and intake. Methods. Participants in a study dinner (n = 303) were randomly assigned to either (1) a menu without calorie labels (no calorie labels), (2) a menu with calorie labels (calorie labels), or (3) a menu with calorie labels and a label stating the recommended daily caloric intake for an average adult (calorie labels plus information). Food choices and intake during and after the study dinner were measured. Results. Participants in both calorie label conditions ordered fewer calories than those in the no calorie labels condition. When calorie label conditions were combined, that group consumed 14% fewer calories than the no calorie labels group. Individuals in the calorie labels condition consumed more calories after the study dinner than those in both other conditions. When calories consumed during and after the study dinner were combined, participants in the calorie labels plus information group consumed an average of 250 fewer calories than those in the other groups. Conclusions. Calorie labels on restaurant menus impacted food choices and intake; adding a recommended daily caloric requirement label increased this effect, suggesting menu label legislation should require such a label. Future research should evaluate menu labeling's impact on children's food choices and consumption. PMID:20019307

  8. School Foodservice Personnel's Struggle with Using Labels to Identify Whole-Grain Foods

    ERIC Educational Resources Information Center

    Chu, Yen Li; Orsted, Mary; Marquart, Len; Reicks, Marla

    2012-01-01

    Objective: To describe how school foodservice personnel use current labeling methods to identify whole-grain products and the influence on purchasing for school meals. Methods: Focus groups explored labeling methods to identify whole-grain products and barriers to incorporating whole-grain foods in school meals. Qualitative analysis procedures and…

  9. Evaluation of methods for detection of fluorescence labeled subcellular objects in microscope images.

    PubMed

    Ruusuvuori, Pekka; Aijö, Tarmo; Chowdhury, Sharif; Garmendia-Torres, Cecilia; Selinummi, Jyrki; Birbaumer, Mirko; Dudley, Aimée M; Pelkmans, Lucas; Yli-Harja, Olli

    2010-05-13

    Several algorithms have been proposed for detecting fluorescently labeled subcellular objects in microscope images. Many of these algorithms have been designed for specific tasks and validated with limited image data. But despite the potential of using extensive comparisons between algorithms to provide useful information to guide method selection and thus more accurate results, relatively few studies have been performed. To better understand algorithm performance under different conditions, we have carried out a comparative study including eleven spot detection or segmentation algorithms from various application fields. We used microscope images from well plate experiments with a human osteosarcoma cell line and frames from image stacks of yeast cells in different focal planes. These experimentally derived images permit a comparison of method performance in realistic situations where the number of objects varies within image set. We also used simulated microscope images in order to compare the methods and validate them against a ground truth reference result. Our study finds major differences in the performance of different algorithms, in terms of both object counts and segmentation accuracies. These results suggest that the selection of detection algorithms for image based screens should be done carefully and take into account different conditions, such as the possibility of acquiring empty images or images with very few spots. Our inclusion of methods that have not been used before in this context broadens the set of available detection methods and compares them against the current state-of-the-art methods for subcellular particle detection.

  10. Superposition and alignment of labeled point clouds.

    PubMed

    Fober, Thomas; Glinca, Serghei; Klebe, Gerhard; Hüllermeier, Eyke

    2011-01-01

    Geometric objects are often represented approximately in terms of a finite set of points in three-dimensional euclidean space. In this paper, we extend this representation to what we call labeled point clouds. A labeled point cloud is a finite set of points, where each point is not only associated with a position in three-dimensional space, but also with a discrete class label that represents a specific property. This type of model is especially suitable for modeling biomolecules such as proteins and protein binding sites, where a label may represent an atom type or a physico-chemical property. Proceeding from this representation, we address the question of how to compare two labeled points clouds in terms of their similarity. Using fuzzy modeling techniques, we develop a suitable similarity measure as well as an efficient evolutionary algorithm to compute it. Moreover, we consider the problem of establishing an alignment of the structures in the sense of a one-to-one correspondence between their basic constituents. From a biological point of view, alignments of this kind are of great interest, since mutually corresponding molecular constituents offer important information about evolution and heredity, and can also serve as a means to explain a degree of similarity. In this paper, we therefore develop a method for computing pairwise or multiple alignments of labeled point clouds. To this end, we proceed from an optimal superposition of the corresponding point clouds and construct an alignment which is as much as possible in agreement with the neighborhood structure established by this superposition. We apply our methods to the structural analysis of protein binding sites.

  11. Water Budget Quick Start Guide

    EPA Pesticide Factsheets

    WaterSense created the Water Budget Tool as one option to help builders, landscape professionals, and irrigation professionals certified by a WaterSense labeled program meet the criteria specified in the WaterSense New Home Specification.

  12. Aquifer water abundance evaluation using a fuzzy- comprehensive weighting method

    NASA Astrophysics Data System (ADS)

    Wei, Z.

    2016-08-01

    Aquifer water abundance evaluation is a highly relevant issue that has been researched for many years. Despite prior research, problems with the conventional evaluation method remain. This paper establishes an aquifer water abundance evaluation method that combines fuzzy evaluation with a comprehensive weighting method to overcome both the subjectivity and lack of conformity in determining weight by pure data analysis alone. First, this paper introduces the principle of a fuzzy-comprehensive weighting method. Second, the example of well field no. 3 (of a coalfield) is used to illustrate the method's process. The evaluation results show that this method is can more suitably meet the real requirements of aquifer water abundance assessment, leading to more precise and accurate evaluations. Ultimately, this paper provides a new method for aquifer water abundance evaluation.

  13. The interactive electrode localization utility: software for automatic sorting and labeling of intracranial subdural electrodes

    PubMed Central

    Tang, Wei; Peled, Noam; Vallejo, Deborah I.; Borzello, Mia; Dougherty, Darin D.; Eskandar, Emad N.; Widge, Alik S.; Cash, Sydney S.; Stufflebeam, Steven M.

    2018-01-01

    Purpose Existing methods for sorting, labeling, registering, and across-subject localization of electrodes in intracranial encephalography (iEEG) may involve laborious work requiring manual inspection of radiological images. Methods We describe a new open-source software package, the interactive electrode localization utility which presents a full pipeline for the registration, localization, and labeling of iEEG electrodes from CT and MR images. In addition, we describe a method to automatically sort and label electrodes from subdural grids of known geometry. Results We validated our software against manual inspection methods in twelve subjects undergoing iEEG for medically intractable epilepsy. Our algorithm for sorting and labeling performed correct identification on 96% of the electrodes. Conclusions The sorting and labeling methods we describe offer nearly perfect performance and the software package we have distributed may simplify the process of registering, sorting, labeling, and localizing subdural iEEG grid electrodes by manual inspection. PMID:27915398

  14. Giardia cyst destruction: effectiveness of six small-quantity water disinfection methods.

    PubMed

    Jarroll, E L; Bingham, A K; Meyer, E A

    1980-01-01

    None of the available chemical methods for disinfecting drinking water has ever been tested for its ability to destory Giardia cysts. We tested the ability of six such methods to act against Giardia, using excystation as the criterion of viability. Two water qualities (cloudy and clear) and two temperatures (3 and 20 degrees C) were tested. At 20 degrees C, using cloudy and clear water, all of the method proved completely effective. However, at 3 degrees C, in cloudy water one method ("saturated" iodine) was less than completely effective, and in clear water four methods (bleach, Globaline, tincture of iodine and "saturated" iodine) failed to destory all of the cysts. The failure of these methods appears to be related to either an insufficient halogen residual or contact time. This study underlines the importance of considering water temperature when employing halogen disinfection methods.

  15. Application of Deep Learning and Supervised Learning Methods to Recognize Nonlinear Hidden Pattern in Water Stress Levels from Spatiotemporal Datasets across Rural and Urban US Counties

    NASA Astrophysics Data System (ADS)

    Eisenhart, T.; Josset, L.; Rising, J. A.; Devineni, N.; Lall, U.

    2017-12-01

    In the wake of recent water crises, the need to understand and predict the risk of water stress in urban and rural areas has grown. This understanding has the potential to improve decision making in public resource management, policy making, risk management and investment decisions. Assuming an underlying relationship between urban and rural water stress and observable features, we apply Deep Learning and Supervised Learning models to uncover hidden nonlinear patterns from spatiotemporal datasets. Results of interest includes prediction accuracy on extreme categories (i.e. urban areas highly prone to water stress) and not solely the average risk for urban or rural area, which adds complexity to the tuning of model parameters. We first label urban water stressed counties using annual water quality violations and compile a comprehensive spatiotemporal dataset that captures the yearly evolution of climatic, demographic and economic factors of more than 3,000 US counties over the 1980-2010 period. As county-level data reporting is not done on a yearly basis, we test multiple imputation methods to get around the issue of missing data. Using Python libraries, TensorFlow and scikit-learn, we apply and compare the ability of, amongst other methods, Recurrent Neural Networks (testing both LSTM and GRU cells), Convolutional Neural Networks and Support Vector Machines to predict urban water stress. We evaluate the performance of those models over multiple time spans and combine methods to diminish the risk of overfitting and increase prediction power on test sets. This methodology seeks to identify hidden nonlinear patterns to assess the predominant data features that influence urban and rural water stress. Results from this application at the national scale will assess the performance of deep learning models to predict water stress risk areas across all US counties and will highlight a predominant Machine Learning method for modeling water stress risk using spatiotemporal

  16. A neural network method to correct bidirectional effects in water-leaving radiance

    NASA Astrophysics Data System (ADS)

    Fan, Yongzhen; Li, Wei; Voss, Kenneth J.; Gatebe, Charles K.; Stamnes, Knut

    2017-02-01

    The standard method to convert the measured water-leaving radiances from the observation direction to the nadir direction developed by Morel and coworkers requires knowledge of the chlorophyll concentration (CHL). Also, the standard method was developed for open ocean water, which makes it unsuitable for turbid coastal waters. We introduce a neural network method to convert the water-leaving radiance (or the corresponding remote sensing reflectance) from the observation direction to the nadir direction. This method does not require any prior knowledge of the water constituents or the inherent optical properties (IOPs). This method is fast, accurate and can be easily adapted to different remote sensing instruments. Validation using NuRADS measurements in different types of water shows that this method is suitable for both open ocean and coastal waters. In open ocean or chlorophyll-dominated waters, our neural network method produces corrections similar to those of the standard method. In turbid coastal waters, especially sediment-dominated waters, a significant improvement was obtained compared to the standard method.

  17. Application of a Label-Free Immunosensor for White Spot Syndrome Virus (WSSV) in Shrimp Cultivation Water.

    PubMed

    Waiyapoka, Thanyaporn; Deachamag, Panchalika; Chotigeat, Wilaiwan; Bunsanong, Nittaya; Kanatharana, Proespichaya; Thavarungkul, Panote; Loyprasert-Thananimit, Suchera

    2015-10-01

    White spot syndrome virus (WSSV) is a major pathogen affecting the shrimp industry worldwide. In a preliminary study, WSSV binding protein (WBP) was specifically bound to the VP26 protein of WSSV. Therefore, we have developed the label-free affinity immunosensor using the WBP together with anti-GST-VP26 for quantitative detection of WSSV in shrimp pond water. When the biological molecules were immobilized on a gold electrode to form a self-assembled monolayer, it was then used to detect WSSV using a flow injection system with optimized conditions. Binding between the different copies of WSSV and the immobilized biological molecules was detected by an impedance change (ΔZ″) in real time. The sensitivity of the developed immunosensor was in the linear range of 1.6 × 10(1)-1.6 × 10(6) copies/μl. The system was highly sensitive for the analysis of WSSV as shown by the lack of impedance change when using yellow head virus (YHV). The developed immunosensor could be reused up to 37 times (relative standard deviation (RSD), 3.24 %) with a good reproducibility of residual activity (80-110 %). The immunosensor was simple to operate, reliable, reproducible, and could be applied for the detection and quantification of WSSV in water during shrimp cultivation.

  18. Energy requirements of lactating women derived from doubly labeled water and milk energy output.

    PubMed

    Butte, N F; Wong, W W; Hopkinson, J M

    2001-01-01

    Instead of using an incremental approach to assess the energy requirements of lactation, a more comprehensive approach may be taken by measuring total energy expenditure (TEE), milk energy output and energy mobilization from tissue stores. The latter approach avoids assumptions regarding energetic efficiency and changes in physical activity and adiposity. The purpose of this study was threefold: to assess the energy requirements of lactation; to compare these estimates with energy requirements in the nonpregnant, nonlactating state and to test for energetic adaptations in basal metabolic rate (BMR) and physical activity during the energy-demanding process of lactation. Milk production and composition, body weight and composition, TEE, BMR and physical activity levels were measured in 24 well-nourished women during exclusive breastfeeding at 3 mo postpartum and after the cessation of breastfeeding at 18 or 24 mo postpartum. TEE was measured by the doubly labeled water method, milk production by 3-d test-weighing, milk energy by bomb calorimetry on a 24-h milk sample, body composition by dual-energy x-ray absorptiometry and BMR by room respiration calorimetry. TEE, BMR and physical activity level (physical activity level = TEE/BMR) did not differ between the lactating and nonlactating state (TEE 10.0 +/- 1.5 versus 10.6 +/- 2.1 MJ/d). Mean milk energy output was equivalent to 2.02 +/- 0.33 MJ/d. Total energy requirements were greater during lactation than afterward (12.0 +/- 1.4 versus 10.6 +/- 2.1 MJ/d, P: = 0.002). Energy mobilization from tissue stores (-0.65 +/- 0.97 MJ/d) resulted in net energy requirements during lactation of 11.4 +/- 1.8 MJ/d. Because adaptations in basal metabolism and physical activity were not evident in these well-nourished women, energy requirements during lactation were met primarily from the diet and only partially by mobilization of tissue stores.

  19. A Highly Selective and Sensitive Fluorescence Detection Method of Glyphosate Based on an Immune Reaction Strategy of Carbon Dot Labeled Antibody and Antigen Magnetic Beads.

    PubMed

    Wang, Duo; Lin, Bixia; Cao, Yujuan; Guo, Manli; Yu, Ying

    2016-08-03

    A sensitive fluorescence detection method for glyphosate (GLY) was established based on immune reaction. First, carbon dot labeled antibodies (lgG-CDs) which were able to specifically identify glyphosate were prepared with the environmentally friendly carbon dots (CDs) and glyphosate antibody (lgG). lgG-CDs could be used to in situ visualize the distribution of glyphosate in plant tissues. In order to eliminate the effects of excess lgG-CDs on the determination of GLY, antigen magnetic beads Fe3O4-GLY based on magnetic nanoparticles Fe3O4 and glyphosate were constructed and utilized to couple with the excess lgG-CDs. After magnetic separation to remove antigen magnetic beads, there was a linear relationship between the fluorescence intensity of lgG-CDs and the logarithmic concentration of glyphosate in the range of 0.01-80 μg/mL with a detection limit of 8 ng/mL. The method was used for the detection of glyphosate in Pearl River water, tea, and soil samples with satisfactory recovery ratio between 87.4% and 103.7%.

  20. Simultaneous Validation of Seven Physical Activity Questionnaires Used in Japanese Cohorts for Estimating Energy Expenditure: A Doubly Labeled Water Study.

    PubMed

    Sasai, Hiroyuki; Nakata, Yoshio; Murakami, Haruka; Kawakami, Ryoko; Nakae, Satoshi; Tanaka, Shigeho; Ishikawa-Takata, Kazuko; Yamada, Yosuke; Miyachi, Motohiko

    2018-04-28

    Physical activity questionnaires (PAQs) used in large-scale Japanese cohorts have rarely been simultaneously validated against the gold standard doubly labeled water (DLW) method. This study examined the validity of seven PAQs used in Japan for estimating energy expenditure against the DLW method. Twenty healthy Japanese adults (9 men; mean age, 32.4 [standard deviation {SD}, 9.4] years, mainly researchers and students) participated in this study. Fifteen-day daily total energy expenditure (TEE) and basal metabolic rate (BMR) were measured using the DLW method and a metabolic chamber, respectively. Activity energy expenditure (AEE) was calculated as TEE - BMR - 0.1 × TEE. Seven PAQs were self-administered to estimate TEE and AEE. The mean measured values of TEE and AEE were 2,294 (SD, 318) kcal/day and 721 (SD, 161) kcal/day, respectively. All of the PAQs indicated moderate-to-strong correlations with the DLW method in TEE (rho = 0.57-0.84). Two PAQs (Japan Public Health Center Study [JPHC]-PAQ Short and JPHC-PAQ Long) showed significant equivalence in TEE and moderate intra-class correlation coefficients (ICC). None of the PAQs showed significantly equivalent AEE estimates, with differences ranging from -547 to 77 kcal/day. Correlations and ICCs in AEE were mostly weak or fair (rho = 0.02-0.54, and ICC = 0.00-0.44). Only JPHC-PAQ Short provided significant and fair agreement with the DLW method. TEE estimated by the PAQs showed moderate or strong correlations with the results of DLW. Two PAQs showed equivalent TEE and moderate agreement. None of the PAQs showed equivalent AEE estimation to the gold standard, with weak-to-fair correlations and agreements. Further studies with larger sample sizes are needed to confirm these findings.

  1. International experiences in assessing vitamin A status and applying the vitamin A-labeled isotope dilution method.

    PubMed

    Lopez-Teros, Veronica; Chileshe, Justin; Idohou-Dossou, Nicole; Fajarwati, Tetra; Medoua Nama, Gabriel; Newton, Sam; Vinod Kumar, Malavika; Wang, Zhixu; Wasantwisut, Emorn; Hunt, Janet R

    2014-01-01

    Inadequate vitamin A (VA) nutrition continues to be a major problem worldwide, and many interventions being implemented to improve VA status in various populations need to be evaluated. The interpretation of results after an intervention depends greatly on the method selected to assess VA status. To evaluate the effect of an intervention on VA status, researchers in Cameroon, India, Indonesia, Mexico, Senegal and Zambia have used serum retinol as an indicator, and have not always found improvement in response to supplementation. One problem is that homeostatic control of serum retinol may mask positive effects of treatment in that changes in concentration are observed only when status is either moderately to severely depleted or excessive. Because VA is stored mainly in the liver, measurements of hepatic VA stores are the “gold standard” for assessing VA status. Dose response tests such as the relative dose response (RDR) and the modified relative dose response (MRDR), allow a qualitative assessment of VA liver stores. On the other hand, the use of the vitamin A-labeled isotope dilution (VALID) technique, (using 13C or 2H-labeled retinyl acetate) serves as an indirect method to quantitatively estimate total body and liver VA stores. Countries including Cameroon, China, Ghana, Mexico, Thailand and Zambia are now applying the VALID method to sensitively assess changes in VA status during interventions, or to estimate a population’s dietary requirement for VA. Transition to the use of more sensitive biochemical indicators of VA status such as the VALID technique is needed to effectively assess interventions in populations where mild to moderate VA deficiency is more prevalent than severe deficiency.

  2. Preparation, characterization and pharmacokinetics of fluorescence labeled propylene glycol alginate sodium sulfate

    NASA Astrophysics Data System (ADS)

    Li, Pengli; Li, Chunxia; Xue, Yiting; Zhang, Yang; Liu, Hongbing; Zhao, Xia; Yu, Guangli; Guan, Huashi

    2014-08-01

    A rapid and sensitive fluorescence labeling method was developed and validated for the microanalysis of a sulfated polysaccharide drug,namely propylene glycol alginate sodium sulfate (PSS), in rat plasma. Fluorescein isothiocyanate (FITC) was selected to label PSS, and 1, 6-diaminohexane was used to link PSS and FITC in order to prepare FITC-labeled PSS (F-PSS) through a reductive amination reaction. F-PSS was identified by UV-Vis, FT-IR and 1H-NMR spectrum. The cell stability and cytotoxicity of F-PSS were tested in Madin-Darby canine kidney (MDCK) cells. The results indicated that the labeling efficiency of F-PSS was 0.522% ± 0.0248% and the absolute bioavailability was 8.39%. F-PSS was stable in MDCK cells without obvious cytotoxicity. The method was sensitive and reliable; it showed a good linearity, precision, recovery and stability. The FITC labeling method can be applied to investigating the absorption and metabolism of PSS and other polysaccharides in biological samples.

  3. 50 CFR 216.91 - Dolphin-safe labeling standards.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... MAMMALS Dolphin Safe Tuna Labeling § 216.91 Dolphin-safe labeling standards. (a) It is a violation of..., distributor, or seller of any tuna products that are exported from or offered for sale in the United States to... suggests that the tuna contained in the products were harvested using a method of fishing that is not...

  4. 50 CFR 216.91 - Dolphin-safe labeling standards.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... MAMMALS Dolphin Safe Tuna Labeling § 216.91 Dolphin-safe labeling standards. (a) It is a violation of..., distributor, or seller of any tuna products that are exported from or offered for sale in the United States to... suggests that the tuna contained in the products were harvested using a method of fishing that is not...

  5. 50 CFR 216.91 - Dolphin-safe labeling standards.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... MAMMALS Dolphin Safe Tuna Labeling § 216.91 Dolphin-safe labeling standards. (a) It is a violation of..., distributor, or seller of any tuna products that are exported from or offered for sale in the United States to... suggests that the tuna contained in the products were harvested using a method of fishing that is not...

  6. 50 CFR 216.91 - Dolphin-safe labeling standards.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... MAMMALS Dolphin Safe Tuna Labeling § 216.91 Dolphin-safe labeling standards. (a) It is a violation of..., distributor, or seller of any tuna products that are exported from or offered for sale in the United States to... suggests that the tuna contained in the products were harvested using a method of fishing that is not...

  7. 50 CFR 216.91 - Dolphin-safe labeling standards.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... MAMMALS Dolphin Safe Tuna Labeling § 216.91 Dolphin-safe labeling standards. (a) It is a violation of..., distributor, or seller of any tuna products that are exported from or offered for sale in the United States to... suggests that the tuna contained in the products were harvested using a method of fishing that is not...

  8. Al18F-Labeling Of Heat-Sensitive Biomolecules for Positron Emission Tomography Imaging.

    PubMed

    Cleeren, Frederik; Lecina, Joan; Ahamed, Muneer; Raes, Geert; Devoogdt, Nick; Caveliers, Vicky; McQuade, Paul; Rubins, Daniel J; Li, Wenping; Verbruggen, Alfons; Xavier, Catarina; Bormans, Guy

    2017-01-01

    Positron emission tomography (PET) using radiolabeled biomolecules is a translational molecular imaging technology that is increasingly used in support of drug development. Current methods for radiolabeling biomolecules with fluorine-18 are laborious and require multistep procedures with moderate labeling yields. The Al 18 F-labeling strategy involves chelation in aqueous medium of aluminum mono[ 18 F]fluoride ({Al 18 F} 2+ ) by a suitable chelator conjugated to a biomolecule. However, the need for elevated temperatures (100-120 °C) required for the chelation reaction limits its widespread use. Therefore, we designed a new restrained complexing agent (RESCA) for application of the AlF strategy at room temperature. Methods. The new chelator RESCA was conjugated to three relevant biologicals and the constructs were labeled with {Al 18 F} 2+ to evaluate the generic applicability of the one-step Al 18 F-RESCA-method. Results. We successfully labeled human serum albumin with excellent radiochemical yields in less than 30 minutes and confirmed in vivo stability of the Al 18 F-labeled protein in rats. In addition, we efficiently labeled nanobodies targeting the Kupffer cell marker CRIg, and performed µPET studies in healthy and CRIg deficient mice to demonstrate that the proposed radiolabeling method does not affect the functional integrity of the protein. Finally, an affibody targeting HER2 (PEP04314) was labeled site-specifically, and the distribution profile of (±)-[ 18 F]AlF(RESCA)-PEP04314 in a rhesus monkey was compared with that of [ 18 F]AlF(NOTA)-PEP04314 using whole-body PET/CT. Conclusion. This generic radiolabeling method has the potential to be a kit-based fluorine-18 labeling strategy, and could have a large impact on PET radiochemical space, potentially enabling the development of many new fluorine-18 labeled protein-based radiotracers.

  9. Al18F-Labeling Of Heat-Sensitive Biomolecules for Positron Emission Tomography Imaging

    PubMed Central

    Cleeren, Frederik; Lecina, Joan; Ahamed, Muneer; Raes, Geert; Devoogdt, Nick; Caveliers, Vicky; McQuade, Paul; Rubins, Daniel J; Li, Wenping; Verbruggen, Alfons; Xavier, Catarina; Bormans, Guy

    2017-01-01

    Positron emission tomography (PET) using radiolabeled biomolecules is a translational molecular imaging technology that is increasingly used in support of drug development. Current methods for radiolabeling biomolecules with fluorine-18 are laborious and require multistep procedures with moderate labeling yields. The Al18F-labeling strategy involves chelation in aqueous medium of aluminum mono[18F]fluoride ({Al18F}2+) by a suitable chelator conjugated to a biomolecule. However, the need for elevated temperatures (100-120 °C) required for the chelation reaction limits its widespread use. Therefore, we designed a new restrained complexing agent (RESCA) for application of the AlF strategy at room temperature. Methods. The new chelator RESCA was conjugated to three relevant biologicals and the constructs were labeled with {Al18F}2+ to evaluate the generic applicability of the one-step Al18F-RESCA-method. Results. We successfully labeled human serum albumin with excellent radiochemical yields in less than 30 minutes and confirmed in vivo stability of the Al18F-labeled protein in rats. In addition, we efficiently labeled nanobodies targeting the Kupffer cell marker CRIg, and performed µPET studies in healthy and CRIg deficient mice to demonstrate that the proposed radiolabeling method does not affect the functional integrity of the protein. Finally, an affibody targeting HER2 (PEP04314) was labeled site-specifically, and the distribution profile of (±)-[18F]AlF(RESCA)-PEP04314 in a rhesus monkey was compared with that of [18F]AlF(NOTA)-PEP04314 using whole-body PET/CT. Conclusion. This generic radiolabeling method has the potential to be a kit-based fluorine-18 labeling strategy, and could have a large impact on PET radiochemical space, potentially enabling the development of many new fluorine-18 labeled protein-based radiotracers. PMID:28824726

  10. GEO Label: User and Producer Perspectives on a Label for Geospatial Data

    NASA Astrophysics Data System (ADS)

    Lush, V.; Lumsden, J.; Masó, J.; Díaz, P.; McCallum, I.

    2012-04-01

    One of the aims of the Science and Technology Committee (STC) of the Group on Earth Observations (GEO) was to establish a GEO Label- a label to certify geospatial datasets and their quality. As proposed, the GEO Label will be used as a value indicator for geospatial data and datasets accessible through the Global Earth Observation System of Systems (GEOSS). It is suggested that the development of such a label will significantly improve user recognition of the quality of geospatial datasets and that its use will help promote trust in datasets that carry the established GEO Label. Furthermore, the GEO Label is seen as an incentive to data providers. At the moment GEOSS contains a large amount of data and is constantly growing. Taking this into account, a GEO Label could assist in searching by providing users with visual cues of dataset quality and possibly relevance; a GEO Label could effectively stand as a decision support mechanism for dataset selection. Currently our project - GeoViQua, - together with EGIDA and ID-03 is undertaking research to define and evaluate the concept of a GEO Label. The development and evaluation process will be carried out in three phases. In phase I we have conducted an online survey (GEO Label Questionnaire) to identify the initial user and producer views on a GEO Label or its potential role. In phase II we will conduct a further study presenting some GEO Label examples that will be based on Phase I. We will elicit feedback on these examples under controlled conditions. In phase III we will create physical prototypes which will be used in a human subject study. The most successful prototypes will then be put forward as potential GEO Label options. At the moment we are in phase I, where we developed an online questionnaire to collect the initial GEO Label requirements and to identify the role that a GEO Label should serve from the user and producer standpoint. The GEO Label Questionnaire consists of generic questions to identify whether

  11. Summary of water body extraction methods based on ZY-3 satellite

    NASA Astrophysics Data System (ADS)

    Zhu, Yu; Sun, Li Jian; Zhang, Chuan Yin

    2017-12-01

    Extracting from remote sensing images is one of the main means of water information extraction. Affected by spectral characteristics, many methods can be not applied to the satellite image of ZY-3. To solve this problem, we summarize the extraction methods for ZY-3 and analyze the extraction results of existing methods. According to the characteristics of extraction results, the method of WI& single band threshold and the method of texture filtering based on probability statistics are explored. In addition, the advantages and disadvantages of all methods are compared, which provides some reference for the research of water extraction from images. The obtained conclusions are as follows. 1) NIR has higher water sensitivity, consequently when the surface reflectance in the study area is less similar to water, using single band threshold method or multi band operation can obtain the ideal effect. 2) Compared with the water index and HIS optimal index method, object extraction method based on rules, which takes into account not only the spectral information of the water, but also space and texture feature constraints, can obtain better extraction effect, yet the image segmentation process is time consuming and the definition of the rules requires a certain knowledge. 3) The combination of the spectral relationship and water index can eliminate the interference of the shadow to a certain extent. When there is less small water or small water is not considered in further study, texture filtering based on probability statistics can effectively reduce the noises in result and avoid mixing shadows or paddy field with water in a certain extent.

  12. Joint learning of labels and distance metric.

    PubMed

    Liu, Bo; Wang, Meng; Hong, Richang; Zha, Zhengjun; Hua, Xian-Sheng

    2010-06-01

    Machine learning algorithms frequently suffer from the insufficiency of training data and the usage of inappropriate distance metric. In this paper, we propose a joint learning of labels and distance metric (JLLDM) approach, which is able to simultaneously address the two difficulties. In comparison with the existing semi-supervised learning and distance metric learning methods that focus only on label prediction or distance metric construction, the JLLDM algorithm optimizes the labels of unlabeled samples and a Mahalanobis distance metric in a unified scheme. The advantage of JLLDM is multifold: 1) the problem of training data insufficiency can be tackled; 2) a good distance metric can be constructed with only very few training samples; and 3) no radius parameter is needed since the algorithm automatically determines the scale of the metric. Extensive experiments are conducted to compare the JLLDM approach with different semi-supervised learning and distance metric learning methods, and empirical results demonstrate its effectiveness.

  13. Glycan reductive isotope labeling for quantitative glycomics.

    PubMed

    Xia, Baoyun; Feasley, Christa L; Sachdev, Goverdhan P; Smith, David F; Cummings, Richard D

    2009-04-15

    Many diseases and disorders are characterized by quantitative and/or qualitative changes in complex carbohydrates. Mass spectrometry methods show promise in monitoring and detecting these important biological changes. Here we report a new glycomics method, termed glycan reductive isotope labeling (GRIL), where free glycans are derivatized by reductive amination with the differentially coded stable isotope tags [(12)C(6)]aniline and [(13)C(6)]aniline. These dual-labeled aniline-tagged glycans can be recovered by reverse-phase chromatography and can be quantified based on ultraviolet (UV) absorbance and relative ion abundances. Unlike previously reported isotopically coded reagents for glycans, GRIL does not contain deuterium, which can be chromatographically resolved. Our method shows no chromatographic resolution of differentially labeled glycans. Mixtures of differentially tagged glycans can be directly compared and quantified using mass spectrometric techniques. We demonstrate the use of GRIL to determine relative differences in glycan amount and composition. We analyze free glycans and glycans enzymatically or chemically released from a variety of standard glycoproteins, as well as human and mouse serum glycoproteins, using this method. This technique allows linear relative quantitation of glycans over a 10-fold concentration range and can accurately quantify sub-picomole levels of released glycans, providing a needed advancement in the field of glycomics.

  14. Interpreting labels of abuse-deterrent opioid analgesics.

    PubMed

    Webster, Lynn R

    To provide an overview of available abuse-deterrent opioids (ADOs) and the labeling text that describes abuse-deterrent (AD) properties. A nonsystematic review of ADO literature and regulatory documents guiding their development. A critical assessment and discussion of common routes of opioid abuse, AD methods and properties, US Food and Drug Administration (FDA) study requirements to achieve AD labeling, and brief guide to understanding AD labels. The FDA has issued guidance as incentive and direction to industry to develop ADOs as one component of a multi-pronged public-health strategy to combat opioid abuse and misuse. The guidance describes separate categories of premarket and postmarket studies and makes recommendations for claims that may be made based on study findings. Ten ADOs have FDA-approved labeling attesting to AD properties. Available formulations that fail to conform to FDA guidance in study and labeling recommendations cannot be considered ADO. Formulations with AD properties are expected to reduce risk compared to the same agents without AD properties but cannot prevent all abuse and adverse clinical outcomes.

  15. Simultaneous determination of water-soluble vitamins in beverages and dietary supplements by LC-MS/MS.

    PubMed

    Kakitani, Ayano; Inoue, Tomonori; Matsumoto, Keiko; Watanabe, Jun; Nagatomi, Yasushi; Mochizuki, Naoki

    2014-01-01

    An LC-MS/MS method was developed for the simultaneous determination of 15 water-soluble vitamins that are widely used as additives in beverages and dietary supplements. This combined method involves the following simple pre-treatment procedures: dietary supplement samples were prepared by centrifugation and filtration after an extraction step, whereas beverage samples were diluted prior to injection. Chromatographic analysis in this method utilised a multi-mode ODS column, which provided reverse-phase, anion- and cation-exchange capacities, and therefore improved the retention of highly polar analytes such as water-soluble vitamins. Additionally, the multi-mode ODS column did not require adding ion pair reagents to the mobile phase. We optimised the chromatographic separation of 15 water-soluble vitamins by adjusting the mobile phase pH and the organic solvent. We also conducted an analysis of a NIST Standard Reference Material (SRM 3280 Multi-vitamin/Multi-element tablets) using this method to verify its accuracy. In addition, the method was applied to identify the vitamins in commercial beverages and dietary supplements. By comparing results with the label values and results obtained by official methods, it was concluded that the method could be used for quality control and to compose nutrition labels for vitamin-enriched products.

  16. Dynamic map labeling.

    PubMed

    Been, Ken; Daiches, Eli; Yap, Chee

    2006-01-01

    We address the problem of filtering, selecting and placing labels on a dynamic map, which is characterized by continuous zooming and panning capabilities. This consists of two interrelated issues. The first is to avoid label popping and other artifacts that cause confusion and interrupt navigation, and the second is to label at interactive speed. In most formulations the static map labeling problem is NP-hard, and a fast approximation might have O(nlogn) complexity. Even this is too slow during interaction, when the number of labels shown can be several orders of magnitude less than the number in the map. In this paper we introduce a set of desiderata for "consistent" dynamic map labeling, which has qualities desirable for navigation. We develop a new framework for dynamic labeling that achieves the desiderata and allows for fast interactive display by moving all of the selection and placement decisions into the preprocessing phase. This framework is general enough to accommodate a variety of selection and placement algorithms. It does not appear possible to achieve our desiderata using previous frameworks. Prior to this paper, there were no formal models of dynamic maps or of dynamic labels; our paper introduces both. We formulate a general optimization problem for dynamic map labeling and give a solution to a simple version of the problem. The simple version is based on label priorities and a versatile and intuitive class of dynamic label placements we call "invariant point placements". Despite these restrictions, our approach gives a useful and practical solution. Our implementation is incorporated into the G-Vis system which is a full-detail dynamic map of the continental USA. This demo is available through any browser.

  17. Neural network method to correct bidirectional effects in water-leaving radiance.

    PubMed

    Fan, Yongzhen; Li, Wei; Voss, Kenneth J; Gatebe, Charles K; Stamnes, Knut

    2016-01-01

    Ocean color algorithms that rely on "atmospherically corrected" nadir water-leaving radiances to infer information about marine constituents such as the chlorophyll concentration depend on a reliable method to convert the angle-dependent measured radiances from the observation direction to the nadir direction. It is also important to convert the measured radiances to the nadir direction when comparing and merging products from different satellite missions. The standard correction method developed by Morel and coworkers requires knowledge of the chlorophyll concentration. Also, the standard method was developed based on the Case 1 (open ocean) assumption, which makes it unsuitable for Case 2 situations such as turbid coastal waters. We introduce a neural network method to convert the angle-dependent water-leaving radiance (or the corresponding remote sensing reflectance) from the observation direction to the nadir direction. This method relies on neither an "atmospheric correction" nor prior knowledge of the water constituents or the inherent optical properties. It directly converts the remote sensing reflectance from an arbitrary slanted viewing direction to the nadir direction by using a trained neural network. This method is fast and accurate, and it can be easily adapted to different remote sensing instruments. Validation using NuRADS measurements in different types of water shows that this method is suitable for both Case 1 and Case 2 waters. In Case 1 or chlorophyll-dominated waters, our neural network method produces corrections similar to those of the standard method. In Case 2 waters, especially sediment-dominated waters, a significant improvement was obtained compared to the standard method.

  18. Water Quality Assessment for Deep-water Channel area of Guangzhou Port based on the Comprehensive Water Quality Identification Index Method

    NASA Astrophysics Data System (ADS)

    Chen, Yi

    2018-03-01

    The comprehensive water quality identification index method is able to assess the general water quality situation comprehensively and represent the water quality classification; water environment functional zone achieves pollution level and standard objectively and systematically. This paper selects 3 representative zones along deep-water channel of Guangzhou port and applies comprehensive water quality identification index method to calculate sea water quality monitoring data for different selected zones from year 2006 to 2014, in order to investigate the temporal variation of water quality along deep-water channel of Guangzhou port. The comprehensive water quality level from north to south presents an increased trend, and the water quality of the three zones in 2014 is much better than in 2006. This paper puts forward environmental protection measurements and suggestions for Pearl River Estuary, provides data support and theoretical basis for studied sea area pollution prevention and control.

  19. Potential Impact of ADHD with Stimulant Medication Label on Teacher Expectations

    ERIC Educational Resources Information Center

    Batzle, Christina S.; Weyandt, Lisa L.; Janusis, Grace M.; DeVietti, Terry L.

    2010-01-01

    Objective: The present study investigated how teachers rated children's Behavior, IQ, and Personality contingent on the presence or absence of an Attention Deficit Hyperactivity Disorder (ADHD) label. Method: Teachers from K-12 read a hypothetical description of either a male or female child with no label, an ADHD label, or an ADHD with stimulant…

  20. Engineering streptokinase for generation of active site-labeled plasminogen analogs*

    PubMed Central

    Laha, Malabika; Panizzi, Peter; Nahrendorf, Matthias; Bock, Paul E.

    2011-01-01

    We previously demonstrated that streptokinase (SK) can be used to generate active site-labeled fluorescent analogs of plasminogen (Pg) by virtue of its non-proteolytic activation of the zymogen. The method is versatile and allows for stoichiometric and active site-specific incorporation of any one of many molecular probes. The limitation of the labeling approach is that it is both time-consuming and low yield. Here we demonstrate an improved method for the preparation of labeled Pg analogs by the use of an engineered SK mutant fusion protein with both COOH- and NH2-terminal His6-tags. The NH2-terminal tag is followed by a tobacco etch virus proteinase cleavage site to ensure that the SK Ile1 residue, essential for conformational activation of Pg, is preserved. The SK COOH-terminal Lys414 residue and residues Arg253-Leu260 in the SK β-domain were deleted to prevent cleavage by plasmin (Pm), and to disable Pg substrate binding to the SK·Pg*/Pm catalytic complexes, respectively. Near-elimination of Pm generation with the SKΔ(R253-L260)ΔK414-His6 mutant increased the yield of labeled Pg 2.6-fold and reduced the time required >2-fold. The versatility of the labeling method was extended to the application of Pg labeled with a near-infrared probe to quantitate Pg receptors on immune cells by flow cytometry. PMID:21570944

  1. A new method of tree xylem water extraction for isotopic analysis

    NASA Astrophysics Data System (ADS)

    Gierke, C.; Newton, B. T.

    2011-12-01

    The Sacramento Mountain Watershed Study in the southern Sacramento Mountains of New Mexico is designed to assess the forest restoration technique of tree thinning in mountain watersheds as an effective method of increasing local and regional groundwater recharge. The project is using a soil water balance approach to quantify the partitioning of local precipitation within this watershed before and after thinning trees. Understanding what sources trees extract their water from (e.g. shallow groundwater, unsaturated fractured bedrock, and soils) is difficult due to a complex hydrologic system and heterogeneous distribution of soil thicknesses. However, in order to accurately quantify the soil water balance and to assess how thinning trees will affect this water balance, it is important determine the sources from which trees extract their water. We plan to use oxygen and hydrogen stable isotopic analysis of various end member waters to identify these different sources. We are in the process of developing a new method of determining the isotopic composition of tree water that has several advantages over conventional methods. Within the tree there is the xylem which transports water from the roots to the leaves and the phloem which transports starches and sugars in a water media throughout the tree. Previous studies have shown that the isotopic composition of xylem water accurately reflects that of source water, while phloem water has undergone isotopic fractionation during photosynthesis and metabolism. The distillation of water from twigs, which is often used to extract tree water for isotopic analysis, is very labor intensive. Other disadvantages to distillation methods include possible fractionation due to phase changes and the possible extraction of fractionated phloem waters. Employing a new mixing method, the composition of the twig water (TW) can be determined by putting twigs of unknown isotopic water composition into waters of known compositions or initial

  2. A new model for predicting energy requirements of children during catch-up growth developed using doubly labeled water.

    PubMed

    Fjeld, C R; Schoeller, D A; Brown, K H

    1989-05-01

    Energy partitioned to maintenance plus activity, tissue synthesis, and storage was measured in 41 children in early recovery [W/L (wt/length) less than 5th percentile] from severe protein-energy malnutrition and in late recovery (W/L = 25th percentile) to determine energy requirements during catch-up growth. Metabolizable energy intake was measured by bomb calorimetry and metabolic collections. Energy expended (means +/- SD) for maintenance and activity estimated by the doubly labeled water method was 97 +/- 12 kcal/kg FFM (fat-free mass) in early recovery and 98 +/- 12 kcal/kg FFM in late recovery (p greater than 0.5). Energy stored was 5-6 kcal/g of wt gain. Tissue synthesis increased energy expenditure by 1 +/- 0.7 kcal/g gain in both early and late recovery. From these data a mathematical model was developed to predict energy requirements for children during catch-up growth as a function of initial body composition and rate and composition of wt gain. The model for predicting metabolizable energy requirements is [(98 x FFM + A (11.1 B + 2.2 C)], kcal/kg.d, where FFM is fat-free mass expressed as a percentage of body wt, A is wt gain (g/kg.d), B and C are percentage of wt gain/100 as fat and FFM, respectively. The model was tested retrospectively in separate studies of malnourished children.

  3. Multiple immunofluorescence labelling of formalin-fixed paraffin-embedded (FFPE) tissue

    PubMed Central

    Robertson, David; Savage, Kay; Reis-Filho, Jorge S; Isacke, Clare M

    2008-01-01

    Background Investigating the expression of candidate genes in tissue samples usually involves either immunohistochemical labelling of formalin-fixed paraffin-embedded (FFPE) sections or immunofluorescence labelling of cryosections. Although both of these methods provide essential data, both have important limitations as research tools. Consequently, there is a demand in the research community to be able to perform routine, high quality immunofluorescence labelling of FFPE tissues. Results We present here a robust optimised method for high resolution immunofluorescence labelling of FFPE tissues, which involves the combination of antigen retrieval, indirect immunofluorescence and confocal laser scanning microscopy. We demonstrate the utility of this method with examples of immunofluorescence labelling of human kidney, human breast and a tissue microarray of invasive human breast cancers. Finally, we demonstrate that stained slides can be stored in the short term at 4°C or in the longer term at -20°C prior to images being collected. This approach has the potential to unlock a large in vivo database for immunofluorescence investigations and has the major advantages over immunohistochemistry in that it provides higher resolution imaging of antigen localization and the ability to label multiple antigens simultaneously. Conclusion This method provides a link between the cell biology and pathology communities. For the cell biologist, it will enable them to utilise the vast archive of pathology specimens to advance their in vitro data into in vivo samples, in particular archival material and tissue microarrays. For the pathologist, it will enable them to utilise multiple antibodies on a single section to characterise particular cell populations or to test multiple biomarkers in limited samples and define with greater accuracy cellular heterogeneity in tissue samples. PMID:18366689

  4. Homogeneous Biosensing Based on Magnetic Particle Labels

    PubMed Central

    Schrittwieser, Stefan; Pelaz, Beatriz; Parak, Wolfgang J.; Lentijo-Mozo, Sergio; Soulantica, Katerina; Dieckhoff, Jan; Ludwig, Frank; Guenther, Annegret; Tschöpe, Andreas; Schotter, Joerg

    2016-01-01

    The growing availability of biomarker panels for molecular diagnostics is leading to an increasing need for fast and sensitive biosensing technologies that are applicable to point-of-care testing. In that regard, homogeneous measurement principles are especially relevant as they usually do not require extensive sample preparation procedures, thus reducing the total analysis time and maximizing ease-of-use. In this review, we focus on homogeneous biosensors for the in vitro detection of biomarkers. Within this broad range of biosensors, we concentrate on methods that apply magnetic particle labels. The advantage of such methods lies in the added possibility to manipulate the particle labels by applied magnetic fields, which can be exploited, for example, to decrease incubation times or to enhance the signal-to-noise-ratio of the measurement signal by applying frequency-selective detection. In our review, we discriminate the corresponding methods based on the nature of the acquired measurement signal, which can either be based on magnetic or optical detection. The underlying measurement principles of the different techniques are discussed, and biosensing examples for all techniques are reported, thereby demonstrating the broad applicability of homogeneous in vitro biosensing based on magnetic particle label actuation. PMID:27275824

  5. Direct fluorescence anisotropy assay for cocaine using tetramethylrhodamine-labeled aptamer.

    PubMed

    Liu, Yingxiong; Zhao, Qiang

    2017-06-01

    Development of simple, sensitive, and rapid method for cocaine detection is important in medicine and drug abuse monitoring. Taking advantage of fluorescence anisotropy and aptamer, this study reports a direct fluorescence anisotropy (FA) assay for cocaine by employing an aptamer probe with tetramethylrhodamine (TMR) labeled on a specific position. The binding of cocaine and the aptamer causes a structure change of the TMR-labeled aptamer, leading to changes of the interaction between labeled TMR and adjacent G bases in aptamer sequence, so FA of TMR varies with increasing of cocaine. After screening different labeling positions of the aptamer, including thymine (T) bases and terminals of the aptamer, we obtained a favorable aptamer probe with TMR labeled on the 25th base T in the sequence, which exhibited sensitive and significant FA-decreasing responses upon cocaine. Under optimized assay conditions, this TMR-labeled aptamer allowed for direct FA detection of cocaine as low as 5 μM. The maximum FA change reached about 0.086. This FA method also enabled the detection of cocaine spiked in diluted serum and urine samples, showing potential for applications. Graphical Abstract The binding of cocaine to the TMR-labeled aptamer causes conformation change and alteration of the intramolecular interaction between TMR and bases of aptamer, leading to variance of fluorescence anisotropy (FA) of TMR, so direct FA analyis of cocaine is achieved.

  6. Methods for computing water-quality loads at sites in the U.S. Geological Survey National Water Quality Network

    USGS Publications Warehouse

    Lee, Casey J.; Murphy, Jennifer C.; Crawford, Charles G.; Deacon, Jeffrey R.

    2017-10-24

    The U.S. Geological Survey publishes information on concentrations and loads of water-quality constituents at 111 sites across the United States as part of the U.S. Geological Survey National Water Quality Network (NWQN). This report details historical and updated methods for computing water-quality loads at NWQN sites. The primary updates to historical load estimation methods include (1) an adaptation to methods for computing loads to the Gulf of Mexico; (2) the inclusion of loads computed using the Weighted Regressions on Time, Discharge, and Season (WRTDS) method; and (3) the inclusion of loads computed using continuous water-quality data. Loads computed using WRTDS and continuous water-quality data are provided along with those computed using historical methods. Various aspects of method updates are evaluated in this report to help users of water-quality loading data determine which estimation methods best suit their particular application.

  7. Menu-Labeling Usage and Its Association with Diet and Exercise: 2011 BRFSS Sugar Sweetened Beverage and Menu Labeling Module

    PubMed Central

    Bowers, Kelly M.

    2014-01-01

    Introduction The primary objective of our study was to investigate the association between menu-labeling usage and healthy behaviors pertaining to diet (consumption of fruits, vegetables, sodas, and sugar-sweetened beverages) and exercise. Methods Data from the 2011 Behavioral Risk Factor Surveillance System, Sugar Sweetened Beverage and Menu-Labeling module, were used. Logistic regression was used to determine the association between menu-labeling usage and explanatory variables that included fruit, vegetable, soda, and sugar-sweetened beverage consumption as well as exercise. Results Nearly half (52%) of the sample indicated that they used menu labeling. People who used menu labeling were more likely to be female (odds ratio [OR], 2.29; 95% confidence interval [CI], 2.04–2.58), overweight (OR, 1.13; 95% CI, 1.00–1.29) or obese (OR, 1.29; 95% CI, 1.12–1.50), obtain adequate weekly aerobic exercise (OR, 1.18; 95% CI, 1.06–1.32), eat fruits (OR, 1.20; 95% CI, 1.12–1.29) and vegetables (OR, 1.12; 95% CI, 1.05–1.20), and drink less soda (OR, 0.76; 95% CI, 0.69–0.83). Conclusion Although obese and overweight people were more likely to use menu labeling, they were also adequately exercising, eating more fruits and vegetables, and drinking less soda. Menu labeling is intended to combat the obesity epidemic; however the results indicate an association between menu-labeling usage and certain healthy behaviors. Thus, efforts may be necessary to increase menu-labeling usage among people who are not partaking in such behaviors. PMID:24384303

  8. Extraction and labeling methods for microarrays using small amounts of plant tissue.

    PubMed

    Stimpson, Alexander J; Pereira, Rhea S; Kiss, John Z; Correll, Melanie J

    2009-03-01

    Procedures were developed to maximize the yield of high-quality RNA from small amounts of plant biomass for microarrays. Two disruption techniques (bead milling and pestle and mortar) were compared for the yield and the quality of RNA extracted from 1-week-old Arabidopsis thaliana seedlings (approximately 0.5-30 mg total biomass). The pestle and mortar method of extraction showed enhanced RNA quality at the smaller biomass samples compared with the bead milling technique, although the quality in the bead milling could be improved with additional cooling steps. The RNA extracted from the pestle and mortar technique was further tested to determine if the small quantity of RNA (500 ng-7 microg) was appropriate for microarray analyses. A new method of low-quantity RNA labeling for microarrays (NuGEN Technologies, Inc.) was used on five 7-day-old seedlings (approximately 2.5 mg fresh weight total) of Arabidopsis that were grown in the dark and exposed to 1 h of red light or continued dark. Microarray analyses were performed on a small plant sample (five seedlings; approximately 2.5 mg) using these methods and compared with extractions performed with larger biomass samples (approximately 500 roots). Many well-known light-regulated genes between the small plant samples and the larger biomass samples overlapped in expression changes, and the relative expression levels of selected genes were confirmed with quantitative real-time polymerase chain reaction, suggesting that these methods can be used for plant experiments where the biomass is extremely limited (i.e. spaceflight studies).

  9. Segmentation and labeling of the ventricular system in normal pressure hydrocephalus using patch-based tissue classification and multi-atlas labeling

    NASA Astrophysics Data System (ADS)

    Ellingsen, Lotta M.; Roy, Snehashis; Carass, Aaron; Blitz, Ari M.; Pham, Dzung L.; Prince, Jerry L.

    2016-03-01

    Normal pressure hydrocephalus (NPH) affects older adults and is thought to be caused by obstruction of the normal flow of cerebrospinal fluid (CSF). NPH typically presents with cognitive impairment, gait dysfunction, and urinary incontinence, and may account for more than five percent of all cases of dementia. Unlike most other causes of dementia, NPH can potentially be treated and the neurological dysfunction reversed by shunt surgery or endoscopic third ventriculostomy (ETV), which drain excess CSF. However, a major diagnostic challenge remains to robustly identify shunt-responsive NPH patients from patients with enlarged ventricles due to other neurodegenerative diseases. Currently, radiologists grade the severity of NPH by detailed examination and measurement of the ventricles based on stacks of 2D magnetic resonance images (MRIs). Here we propose a new method to automatically segment and label different compartments of the ventricles in NPH patients from MRIs. While this task has been achieved in healthy subjects, the ventricles in NPH are both enlarged and deformed, causing current algorithms to fail. Here we combine a patch-based tissue classification method with a registration-based multi-atlas labeling method to generate a novel algorithm that labels the lateral, third, and fourth ventricles in subjects with ventriculomegaly. The method is also applicable to other neurodegenerative diseases such as Alzheimer's disease; a condition considered in the differential diagnosis of NPH. Comparison with state of the art segmentation techniques demonstrate substantial improvements in labeling the enlarged ventricles, indicating that this strategy may be a viable option for the diagnosis and characterization of NPH.

  10. Escherichia coli cell-free protein synthesis and isotope labeling of mammalian proteins.

    PubMed

    Terada, Takaho; Yokoyama, Shigeyuki

    2015-01-01

    This chapter describes the cell-free protein synthesis method, using an Escherichia coli cell extract. This is a cost-effective method for milligram-scale protein production and is particularly useful for the production of mammalian proteins, protein complexes, and membrane proteins that are difficult to synthesize by recombinant expression methods, using E. coli and eukaryotic cells. By adjusting the conditions of the cell-free method, zinc-binding proteins, disulfide-bonded proteins, ligand-bound proteins, etc., may also be produced. Stable isotope labeling of proteins can be accomplished by the cell-free method, simply by using stable isotope-labeled amino acid(s) in the cell-free reaction. Moreover, the cell-free protein synthesis method facilitates the avoidance of stable isotope scrambling and dilution over the recombinant expression methods and is therefore advantageous for amino acid-selective stable isotope labeling. Site-specific stable isotope labeling is also possible with a tRNA molecule specific to the UAG codon. By the cell-free protein synthesis method, coupled transcription-translation is performed from a plasmid vector or a PCR-amplified DNA fragment encoding the protein. A milligram quantity of protein can be produced with a milliliter-scale reaction solution in the dialysis mode. More than a thousand solution structures have been determined by NMR spectroscopy for uniformly labeled samples of human and mouse functional domain proteins, produced by the cell-free method. Here, we describe the practical aspects of mammalian protein production by the cell-free method for NMR spectroscopy. © 2015 Elsevier Inc. All rights reserved.

  11. Multi-atlas segmentation with joint label fusion and corrective learning—an open source implementation

    PubMed Central

    Wang, Hongzhi; Yushkevich, Paul A.

    2013-01-01

    Label fusion based multi-atlas segmentation has proven to be one of the most competitive techniques for medical image segmentation. This technique transfers segmentations from expert-labeled images, called atlases, to a novel image using deformable image registration. Errors produced by label transfer are further reduced by label fusion that combines the results produced by all atlases into a consensus solution. Among the proposed label fusion strategies, weighted voting with spatially varying weight distributions derived from atlas-target intensity similarity is a simple and highly effective label fusion technique. However, one limitation of most weighted voting methods is that the weights are computed independently for each atlas, without taking into account the fact that different atlases may produce similar label errors. To address this problem, we recently developed the joint label fusion technique and the corrective learning technique, which won the first place of the 2012 MICCAI Multi-Atlas Labeling Challenge and was one of the top performers in 2013 MICCAI Segmentation: Algorithms, Theory and Applications (SATA) challenge. To make our techniques more accessible to the scientific research community, we describe an Insight-Toolkit based open source implementation of our label fusion methods. Our implementation extends our methods to work with multi-modality imaging data and is more suitable for segmentation problems with multiple labels. We demonstrate the usage of our tools through applying them to the 2012 MICCAI Multi-Atlas Labeling Challenge brain image dataset and the 2013 SATA challenge canine leg image dataset. We report the best results on these two datasets so far. PMID:24319427

  12. Fracture labelling of boar spermatozoa for the fucose-binding-protein (FBP).

    PubMed

    Friess, A E; Toepfer-Petersen, E; Schill, W B

    1987-01-01

    Labelling of fractured boar spermatozoa with the FUC-HRP gold method for a fucose-binding-protein (FBP) gave evidence the FBP is localized in the acrosomal matrix. All fracture faces through the acrosome from the rostral end towards the equatorial segment show similar labelling pattern. This labelling is completely blocked by preincubation of the fractured tissue with focoidan.

  13. Factors associated with self-reported menu labeling use among US adults

    PubMed Central

    Lee-Kwan, Seung Hee; Pan, Liping; Maynard, Leah M.; McGuire, Lisa C.; Park, Sohyun

    2016-01-01

    Background Menu labeling may help people select foods and beverages with lower calories and is a potential population-based strategy to reduce obesity and diet-related chronic diseases in the United States. Objectives The aim of this cross-sectional study was to examine the prevalence of menu labeling use among adults and its association with sociodemographic, behavioral, and policy factors. Methods 2012 Behavioral Risk Factor Surveillance System data from 17 states that included 100,141 adults who noticed menu labeling at fast food/chain restaurants (“When calorie information is available in the restaurant, how often does this information help you decide what to order?”) were used. Menu labeling use was categorized: frequent (always/most of the time), moderate (half the time/sometimes), and never. Multinomial logistic regression was used to examine associations of sociodemographic, behavioral, and policy factors with menu labeling use. Results Overall, of adults who noticed menu labeling, 25.6% reported frequent use of menu labeling, 31.6% reported moderate use, and 42.7% reported that they never use menu labeling. Compared to never users, frequent users were significantly more likely to be younger, female, non-white, more educated, high-income, overweight or obese, physically active, former- or never-smokers, with no or lower (<1 time/day) sugar-sweetened beverage intake, and living in states where menu labeling legislation was enacted or proposed. Conclusions Menu labeling is one method that consumers can use to help reduce their calorie consumption from restaurants. These findings can be used to develop targeted interventions to increase menu labeling use among subpopulations with lower use. PMID:26875022

  14. Understanding Food Labels

    MedlinePlus

    ... Healthy eating for girls Understanding food labels Understanding food labels There is lots of info on food ... need to avoid because of food allergies. Other food label terms top In addition to the Nutrition ...

  15. Quantitative proteome analysis using isobaric peptide termini labeling (IPTL).

    PubMed

    Arntzen, Magnus O; Koehler, Christian J; Treumann, Achim; Thiede, Bernd

    2011-01-01

    The quantitative comparison of proteome level changes across biological samples has become an essential feature in proteomics that remains challenging. We have recently introduced isobaric peptide termini labeling (IPTL), a novel strategy for isobaric quantification based on the derivatization of peptide termini with complementary isotopically labeled reagents. Unlike non-isobaric quantification methods, sample complexity at the MS level is not increased, providing improved sensitivity and protein coverage. The distinguishing feature of IPTL when comparing it to more established isobaric labeling methods (iTRAQ and TMT) is the presence of quantification signatures in all sequence-determining ions in MS/MS spectra, not only in the low mass reporter ion region. This makes IPTL a quantification method that is accessible to mass spectrometers with limited capabilities in the low mass range. Also, the presence of several quantification points in each MS/MS spectrum increases the robustness of the quantification procedure.

  16. 78 FR 66826 - Prior Label Approval System: Generic Label Approval

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-07

    ... container of a misleading form or size.\\1\\ FSIS has interpreted these provisions as requiring that the...-evaluating-labeling . Labels submitted as an extraordinary circumstance are given the highest priority for... submissions to FSIS headquarters, thus increasing the availability of FSIS labeling staff. Upon publication of...

  17. Investigation of RNA Synthesis Using 5-Bromouridine Labelling and Immunoprecipitation.

    PubMed

    Kofoed, Rikke H; Betzer, Cristine; Lykke-Andersen, Søren; Molska, Ewa; Jensen, Poul H

    2018-05-03

    When steady state RNA levels are compared between two conditions, it is not possible to distinguish whether changes are caused by alterations in production or degradation of RNA. This protocol describes a method for measurement of RNA production, using 5-Bromouridine labelling of RNA followed by immunoprecipitation, which enables investigation of RNA synthesized within a short timeframe (e.g., 1 h). The advantage of 5-Bromouridine-labelling and immunoprecipitation over the use of toxic transcriptional inhibitors, such as α-amanitin and actinomycin D, is that there are no or very low effects on cell viability during short-term use. However, because 5-Bromouridine-immunoprecipitation only captures RNA produced within the short labelling time, slowly produced as well as rapidly degraded RNA can be difficult to measure by this method. The 5-Bromouridine-labelled RNA captured by 5-Bromouridine-immunoprecipitation can be analyzed by reverse transcription, quantitative polymerase chain reaction, and next generation sequencing. All types of RNA can be investigated, and the method is not limited to measuring mRNA as is presented in this example.

  18. Abandoning a label doesn’t make it disappear: The perseverance of labeling effects

    PubMed Central

    Foroni, Francesco; Rothbart, Myron

    2012-01-01

    Labels exert strong influence on perception and judgment. The present experiment examines the possibility that such effects may persist even when labels are abandoned. Participants judged the similarity of pairs of silhouette drawings of female body types, ordered on a continuum from very thin to very heavy, under conditions where category labels were, and were not, superimposed on the ordered stimuli. Consistent with earlier research, labels had strong effects on perceived similarity, with silhouettes sharing the same label judged as more similar than those having different labels. Moreover, when the labels were removed and no longer present, the effect of the labels, although diminished, persisted. It did not make any difference whether the labels were simply abandoned or, in addition, had their validity challenged. The results are important for our understanding of categorization and labeling processes. The potential theoretical and practical implications of these results for social processes are discussed. PMID:23105148

  19. A Generalized Mixture Framework for Multi-label Classification

    PubMed Central

    Hong, Charmgil; Batal, Iyad; Hauskrecht, Milos

    2015-01-01

    We develop a novel probabilistic ensemble framework for multi-label classification that is based on the mixtures-of-experts architecture. In this framework, we combine multi-label classification models in the classifier chains family that decompose the class posterior distribution P(Y1, …, Yd|X) using a product of posterior distributions over components of the output space. Our approach captures different input–output and output–output relations that tend to change across data. As a result, we can recover a rich set of dependency relations among inputs and outputs that a single multi-label classification model cannot capture due to its modeling simplifications. We develop and present algorithms for learning the mixtures-of-experts models from data and for performing multi-label predictions on unseen data instances. Experiments on multiple benchmark datasets demonstrate that our approach achieves highly competitive results and outperforms the existing state-of-the-art multi-label classification methods. PMID:26613069

  20. Labeling of indocyanine green with carrier-free iodine-123

    DOEpatents

    Ansari, Azizullah N.; Lambrecht, Richard M.; Redvanly, Carol S.; Wolf, Alfred P.

    1976-01-01

    The method of labeling indocyanine green (ICG) with carrier-free iodine-123 comprising the steps of condensing xenon-123 on crystals of ICG followed by permitting decay of the .sup.123 Xe a sufficient length of time to produce .sup.123 I-electronically excited ions and atoms which subsequently label ICG.

  1. A combination of positive dielectrophoresis driven on-line enrichment and aptamer-fluorescent silica nanoparticle label for rapid and sensitive detection of Staphylococcus aureus.

    PubMed

    Shangguan, Jingfang; Li, Yuhong; He, Dinggeng; He, Xiaoxiao; Wang, Kemin; Zou, Zhen; Shi, Hui

    2015-07-07

    Staphylococcus aureus (S. aureus) is an important human pathogen that causes several diseases ranging from superficial skin infections to life-threatening diseases. Here, a method combining positive dielectrophoresis (pDEP) driven on-line enrichment and aptamer-fluorescent silica nanoparticle label has been developed for the rapid and sensitive detection of S. aureus in microfluidic channels. An aptamer, having high affinity to S. aureus, is used as the molecular recognition tool and immobilized onto chloropropyl functionalized fluorescent silica nanoparticles through a click chemistry approach to obtain S. aureus aptamer-nanoparticle bioconjugates (Apt(S.aureus)/FNPs). The pDEP driven on-line enrichment technology was used for accumulating the Apt(S.aureus)/FNP labeled S. aureus. After incubating with S. aureus, the mixture of Apt(S.aureus)/FNP labeled S. aureus and Apt(S.aureus)/FNPs was directly introduced into the pDEP-based microfluidic system. By applying an AC voltage in a pDEP frequency region, the Apt(S.aureus)/FNP labelled S. aureus moved to the electrodes and accumulated in the electrode gap, while the free Apt(S.aureus)/FNPs flowed away. The signal that came from the Apt(S.aureus)/FNP labelled S. aureus in the focused detection areas was then detected. Profiting from the specificity of aptamer, signal amplification of FNP label and pDEP on-line enrichment, this assay can detect as low as 93 and 270 cfu mL(-1)S. aureus in deionized water and spiked water samples, respectively, with higher sensitivities than our previously reported Apt(S.aureus)/FNP based flow cytometry. Moreover, without the need for separation and washing steps usually required for FNP label involved bioassays, the total assay time including sample pretreatment was within 2 h.

  2. Lanthanide-labeled clay: A new method for tracing sediment transport in Karst

    USGS Publications Warehouse

    Mahler, B.J.; Bennett, P.C.; Zimmerman, M.

    1998-01-01

    Mobile sediment is a fundamental yet poorly characterized aspect of mass transport through karst aquifers. Here the development and field testing of an extremely sensitive particle tracer that may be used to characterize sediment transport in karst aquifers is described. The tracer consists of micron-size montmorillonite particles homoionized to the lanthanide form; after injection and retrieval from a ground water system, the lanthanide ions are chemically stripped from the clay and quantified by high performance liquid chromatography. The tracer meets the following desired criteria: low detection limit; a number of differentiable signatures; inexpensive production and quantification using standard methods; no environmental risks; and hydrodynamic properties similar to the in situ sediment it is designed to trace. The tracer was tested in laboratory batch experiments and field tested in both surface water and ground water systems. In surface water, arrival times of the tracer were similar to those of a conservative water tracer, although a significant amount of material was lost due to settling. Two tracer tests were undertaken in a karst aquifer under different flow conditions. Under normal flow conditions, the time of arrival and peak concentration of the tracer were similar to or preceded that of a conservative water tracer. Under low flow conditions, the particle tracer was not detected, suggesting that in low flow the sediment settles out of suspension and goes into storage.Mobile sediment is a fundamental yet poorly characterized aspect of mass transport through karst aquifers. Here the development and field testing of an extremely sensitive particle tracer that may be used to characterize sediment transport in karst aquifers is described. The tracer consists of micron-size montmorillonite particles homoionized to the lanthanide form; after injection and retrieval from a ground water system, the lanthanide ions are chemically stripped from the clay and

  3. Reading the Small Print – Labelling Recommendations for Orthopaedic Implants

    PubMed Central

    Haene, Roger A; Sandhu, Ranbir S; Baxandall, Richard

    2009-01-01

    INTRODUCTION There exist, currently, no clear guidelines regarding standards for surgical implant labelling. Dimensions of the laminar flow canopies in orthopaedic use fixes the distance at which implant labels can be read. Mistakes when reading the label on an implant box can pose health risks for patients, and financial consequences for medical institutions. SUBJECTS AND METHODS Using scientifically validated tools such as the Snellen Chart Formula, a theoretical minimum standard for text on implant labels was reached. This theoretical standard was then tested under real operating conditions. After discovering a minimum practical standard for implant labels, the authors then audited current labels in use on a wide range of orthopaedic implant packages. Furthermore, other non-text-related labelling problems were also noted. RESULTS There is a definite minimum standard which should be observed when implant labels are manufactured. Implants in current use bear labels on the packaging that are of an insufficient standard to ensure patient safety in theatre. CONCLUSIONS The authors have established text parameters that will increase the legibility of implant labels. In the interests of improving risk management in theatre, therefore, the authors propose a standard for orthopaedic implant labelling, and believe this will provide a useful foundation for further discussion between the orthopaedic community and implant manufacturers. PMID:19686615

  4. 21 CFR 344.52 - Labeling of ear drying aid drug products.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) Indications. The labeling of the product states, under the heading “Use,” the following: “dries water in the...] washing the hair”). Other truthful and nonmisleading statements, describing only the indications for use...

  5. 40 CFR 600.115-08 - Criteria for determining the fuel economy label calculation method for 2011 and later model year...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Criteria for determining the fuel economy label calculation method for 2011 and later model year vehicles. 600.115-08 Section 600.115-08 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND CARBON-RELATED EXHAUST EMISSIONS OF MOTOR VEHICLE...

  6. Calorie Labeling, Fast Food Purchasing and Restaurant Visits

    PubMed Central

    Elbel, Brian; Mijanovich, Tod; Dixon, Beth; Abrams, Courtney; Weitzman, Beth; Kersh, Rogan; Auchincloss, Amy H.; Ogedegbe, Gbenga

    2013-01-01

    Objective Obesity is a pressing public health problem without proven population-wide solutions. Researchers sought to determine whether a city-mandated policy requiring calorie labeling at fast food restaurants was associated with consumer awareness of labels, calories purchased and fast food restaurant visits. Design and Methods Difference-in-differences design, with data collected from consumers outside fast food restaurants and via a random digit dial telephone survey, before (December 2009) and after (June 2010) labeling in Philadelphia (which implemented mandatory labeling) and Baltimore (matched comparison city). Measures included: self-reported use of calorie information, calories purchased determined via fast food receipts, and self-reported weekly fast-food visits. Results The consumer sample was predominantly Black (71%), and high school educated (62%). Post-labeling, 38% of Philadelphia consumers noticed the calorie labels for a 33 percentage point (p<.001) increase relative to Baltimore. Calories purchased and number of fast food visits did not change in either city over time. Conclusions While some consumer reports noticing and using calorie information, no population level changes were noted in calories purchased or fast food visits. Other controlled studies are needed to examine the longer term impact of labeling as it becomes national law. PMID:24136905

  7. Methods for collection and analysis of water samples

    USGS Publications Warehouse

    Rainwater, Frank Hays; Thatcher, Leland Lincoln

    1960-01-01

    This manual contains methods used by the U.S. Geological Survey to collect, preserve, and analyze water samples. Throughout, the emphasis is on obtaining analytical results that accurately describe the chemical composition of the water in situ. Among the topics discussed are selection of sampling sites, frequency of sampling, field equipment, preservatives and fixatives, analytical techniques of water analysis, and instruments. Seventy-seven laboratory and field procedures are given for determining fifty-three water properties.

  8. Development of Water Softening Method of Intake in Magnitogorsk

    NASA Astrophysics Data System (ADS)

    Meshcherova, E. A.; Novoselova, J. N.; Moreva, J. A.

    2017-11-01

    This article contains an appraisal of the drinking water quality of Magnitogorsk intake. A water analysis was made which led to the conclusion that the standard for general water hardness was exceeded. As a result, it became necessary to develop a number of measures to reduce water hardness. To solve this problem all the necessary studies of the factors affecting the value of increased water hardness were carried out and the water softening method by using an ion exchange filter was proposed. The calculation of the cation-exchanger filling volume of the proposed filter is given in the article, its overall dimensions are chosen. The obtained calculations were confirmed by the results of laboratory studies by using the test installation. The research and laboratory tests results make the authors conclude that the proposed method should be used to obtain softened water for the requirements of SanPin.

  9. Measurement of skeletal muscle perfusion dynamics with pseudo-continuous arterial spin labeling (pCASL): Assessment of relative labeling efficiency at rest and during hyperemia, and comparison to pulsed arterial spin labeling (PASL).

    PubMed

    Englund, Erin K; Rodgers, Zachary B; Langham, Michael C; Mohler, Emile R; Floyd, Thomas F; Wehrli, Felix W

    2016-10-01

    To compare calf skeletal muscle perfusion measured with pulsed arterial spin labeling (PASL) and pseudo-continuous arterial spin labeling (pCASL) methods, and to assess the variability of pCASL labeling efficiency in the popliteal artery throughout an ischemia-reperfusion paradigm. At 3T, relative pCASL labeling efficiency was experimentally assessed in five subjects by measuring the signal intensity of blood in the popliteal artery just distal to the labeling plane immediately following pCASL labeling or control preparation pulses, or without any preparation pulses throughout separate ischemia-reperfusion paradigms. The relative label and control efficiencies were determined during baseline, hyperemia, and recovery. In a separate cohort of 10 subjects, pCASL and PASL sequences were used to measure reactive hyperemia perfusion dynamics. Calculated pCASL labeling and control efficiencies did not differ significantly between baseline and hyperemia or between hyperemia and recovery periods. Relative to the average baseline, pCASL label efficiency was 2 ± 9% lower during hyperemia. Perfusion dynamics measured with pCASL and PASL did not differ significantly (P > 0.05). Average leg muscle peak perfusion was 47 ± 20 mL/min/100g or 50 ± 12 mL/min/100g, and time to peak perfusion was 25 ± 3 seconds and 25 ± 7 seconds from pCASL and PASL data, respectively. Differences of further metrics parameterizing the perfusion time course were not significant between pCASL and PASL measurements (P > 0.05). No change in pCASL labeling efficiency was detected despite the almost 10-fold increase in average blood flow velocity in the popliteal artery. pCASL and PASL provide precise and consistent measurement of skeletal muscle reactive hyperemia perfusion dynamics. J. MAGN. RESON. IMAGING 2016;44:929-939. © 2016 International Society for Magnetic Resonance in Medicine.

  10. Introduction to Pesticide Labels

    EPA Pesticide Factsheets

    Pesticide product labels provide critical information about how to safely and legally handle and use pesticide products. Unlike most other types of product labels, pesticide labels are legally enforceable. Learn about pesticide product labels.

  11. A Cluster-then-label Semi-supervised Learning Approach for Pathology Image Classification.

    PubMed

    Peikari, Mohammad; Salama, Sherine; Nofech-Mozes, Sharon; Martel, Anne L

    2018-05-08

    Completely labeled pathology datasets are often challenging and time-consuming to obtain. Semi-supervised learning (SSL) methods are able to learn from fewer labeled data points with the help of a large number of unlabeled data points. In this paper, we investigated the possibility of using clustering analysis to identify the underlying structure of the data space for SSL. A cluster-then-label method was proposed to identify high-density regions in the data space which were then used to help a supervised SVM in finding the decision boundary. We have compared our method with other supervised and semi-supervised state-of-the-art techniques using two different classification tasks applied to breast pathology datasets. We found that compared with other state-of-the-art supervised and semi-supervised methods, our SSL method is able to improve classification performance when a limited number of labeled data instances are made available. We also showed that it is important to examine the underlying distribution of the data space before applying SSL techniques to ensure semi-supervised learning assumptions are not violated by the data.

  12. Enzymatically Generated CRISPR Libraries for Genome Labeling and Screening

    PubMed Central

    Lane, Andrew B.; Strzelecka, Magdalena; Ettinger, Andreas; Grenfell, Andrew W.; Wittmann, Torsten; Heald, Rebecca

    2015-01-01

    Summary CRISPR-based technologies have emerged as powerful tools to alter genomes and mark chromosomal loci, but an inexpensive method for generating large numbers of RNA guides for whole genome screening and labeling is lacking. Using a method that permits library construction from any source of DNA, we generated guide libraries that label repetitive loci or a single chromosomal locus in Xenopus egg extracts and show that a complex library can target the E. coli genome at high frequency. PMID:26212133

  13. Labeling and Magnetic Resonance Imaging of Exosomes Isolated from Adipose Stem Cells.

    PubMed

    Busato, Alice; Bonafede, Roberta; Bontempi, Pietro; Scambi, Ilaria; Schiaffino, Lorenzo; Benati, Donatella; Malatesta, Manuela; Sbarbati, Andrea; Marzola, Pasquina; Mariotti, Raffaella

    2017-06-19

    Adipose stem cells (ASC) represent a promising therapeutic approach for neurodegenerative diseases. Most biological effects of ASC are probably mediated by extracellular vesicles, such as exosomes, which influence the surrounding cells. Current development of exosome therapies requires efficient and noninvasive methods to localize, monitor, and track the exosomes. Among imaging methods used for this purpose, magnetic resonance imaging (MRI) has advantages: high spatial resolution, rapid in vivo acquisition, and radiation-free operation. To be detectable with MRI, exosomes must be labeled with MR contrast agents, such as ultra-small superparamagnetic iron oxide nanoparticles (USPIO). Here, we set up an innovative approach for exosome labeling that preserves their morphology and physiological characteristics. We show that by labeling ASC with USPIO before extraction of nanovesicles, the isolated exosomes retain nanoparticles and can be visualized by MRI. The current work aims at validating this novel USPIO-based exosome labeling method by monitoring the efficiency of the labeling with MRI both in ASC and in exosomes. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  14. A Simple Picaxe Microcontroller Pulse Source for Juxtacellular Neuronal Labelling.

    PubMed

    Verberne, Anthony J M

    2016-10-19

    Juxtacellular neuronal labelling is a method which allows neurophysiologists to fill physiologically-identified neurons with small positively-charged marker molecules. Labelled neurons are identified by histochemical processing of brain sections along with immunohistochemical identification of neuropeptides, neurotransmitters, neurotransmitter transporters or biosynthetic enzymes. A microcontroller-based pulser circuit and associated BASIC software script is described for incorporation into the design of a commercially-available intracellular electrometer for use in juxtacellular neuronal labelling. Printed circuit board construction has been used for reliability and reproducibility. The current design obviates the need for a separate digital pulse source and simplifies the juxtacellular neuronal labelling procedure.

  15. Gluten and gluten-free: issues and considerations of labeling regulations, detection methods, and assay validation.

    PubMed

    Diaz-Amigo, Carmen; Popping, Bert

    2012-01-01

    Gluten is a commonly used cereal derivative found in bakery products, among other items. In some susceptible individuals, however, it triggers immune responses of different kinds; there is, to a lesser extent, the wheat allergy that is immunoglobulin E (IgE)-mediated and leads to histamine release and typical allergic symptoms. In this case, other water-soluble proteins, like albumins, are also involved. On the other hand, there is, more frequently, celiac disease (CD), where the gluten causes immune reactions in the intestines of certain individuals, leading to degeneration of villi, which typically leads to malabsorption of nutrients and, consequently, malnutrition. The only currently effective health strategy for affected consumers is avoidance of gluten-containing products, based on clear labeling rules. However, despite unanimously accepted Codex definitions by all member jurisdictions, the national implementation of equivalent laws shows significant differences. In the context of CD and in support of the gluten-free statement, regulatory enforcement, as well as manufacturers' quality controls are mostly based on analytical results. However, numerous methods are available, some of which have been validated better than others, and many provide different results on identical samples. Reasons include detection of different gluten components and variability in extraction efficiency due to different buffer compositions, especially from processed foods. Last but not least, the lack of reference materials is hindering the process of generating comparable data across different ELISA kits, as well as other methods. How can such data still be used to support a gluten-free claim? New methodologies, in particular mass spectrometric analysis of gluten derived peptides, are being introduced in numerous laboratories. This methodology is not only capable of detecting gluten derived peptides but can also differentiate between and quantitate wheat, barley, rye, and oat. This

  16. Chemiluminescent labels released from long spacer arm-functionalized magnetic particles: a novel strategy for ultrasensitive and highly selective detection of pathogen infections.

    PubMed

    Yang, Haowen; Liang, Wenbiao; He, Nongyue; Deng, Yan; Li, Zhiyang

    2015-01-14

    Previously, the unique advantages provided by chemiluminescence (CL) and magnetic particles (MPs) have resulted in the development of many useful nucleic acid detection methods. CL is highly sensitive, but when applied to MPs, its intensity is limited by the inner filter-like effect arising from excess dark MPs. Herein, we describe a modified strategy whereby CL labels are released from MPs to eliminate this negative effect. This approach relies on (1) the magnetic capture of target molecules on long spacer arm-functionalized magnetic particles (LSA-MPs), (2) the conjugation of streptavidin-alkaline phosphatase (SA-AP) to biotinylated amplicons of target pathogens, (3) the release of CL labels (specifically, AP tags), and (4) the detection of the released labels. CL labels were released from LSA-MPs through LSA ultrasonication or DNA enzymolysis, which proved to be the superior method. In contrast to conventional MPs, LSA-MPs exhibited significantly improved CL detection, because of the introduction of LSA, which was made of water-soluble carboxymethylated β-1,3-glucan. Detection of hepatitis B virus with this technique revealed a low detection limit of 50 fM, high selectivity, and excellent reproducibility. Thus, this approach may hold great potential for early stage clinical diagnosis of infectious diseases.

  17. Protein labelling: Playing tag with proteins

    NASA Astrophysics Data System (ADS)

    Romanini, Dante W.; Cornish, Virginia W.

    2012-04-01

    Fluorescent labels can now be attached to a specific protein on the surface of live cells using a two-step method that reacts a norbornene -- introduced using genetic encoding -- with a variety of dyes.

  18. Evaluation of adverse drug event information in US manufacturer labels.

    PubMed

    Harrington, Catherine A; Garcia, Angela S; Sircar-Ramsewak, Feroza

    2011-02-01

    Pharmaceutical manufacturer labels are an important source of adverse drug event (ADE) information. The study objective was to determine the sufficiency of ADE reporting in US drug labels. A sample of 50 labels was evaluated from the top 200 drugs dispensed in the US. Electronic copies of labels were obtained and reviewed by 2 pharmacists for ADE incidence and discontinuation data. ADE incidence data were provided in 86% of labels. However, discontinuation rates due to ADEs and ADE incidence by dose were only reported in 60%. ADE incidence reporting by age (46%) or gender (18%) was also low. ADEs that occurred in less than 2% of the population were rarely reported. Incidence rates were based on small populations (median of 794) and short term studies (median of 84 days for chronic conditions). Labels for 19 drugs used chronically had no long term study data. Methods for collecting ADE data were stated in only 12% of labels. Adverse drug event and drug discontinuation data is under-reported in US labels. More information on adverse events causing discontinuation (especially serious events) and those related to dose, age, and gender is needed in labels to ensure safe prescribing and dispensing of drugs.

  19. Rapid 3D NMR using the filter diagonalization method: application to oligosaccharides derivatized with 13C-labeled acetyl groups

    NASA Astrophysics Data System (ADS)

    Armstrong, Geoffrey S.; Cano, Kristin E.; Mandelshtam, Vladimir A.; Shaka, A. J.; Bendiak, Brad

    2004-09-01

    Rapid 3D NMR spectroscopy of oligosaccharides having isotopically labeled acetyl "isotags" was made possible with high resolution in the indirect dimensions using the filter diagonalization method (FDM). A pulse sequence was designed for the optimal correlation of acetyl methyl protons, methyl carbons, and carbonyl carbons. The multi-dimensional nature of the FDM, coupled with the advantages of constant-time evolution periods, resulted in marked improvements over Fourier transform (FT) and mirror-image linear prediction (MI-LP) processing methods. The three methods were directly compared using identical data sets. A highly resolved 3D spectrum was achieved with the FDM using a very short experimental time (28 min).

  20. Rapid 3D NMR using the filter diagonalization method: application to oligosaccharides derivatized with 13C-labeled acetyl groups.

    PubMed

    Armstrong, Geoffrey S; Cano, Kristin E; Mandelshtam, Vladimir A; Shaka, A J; Bendiak, Brad

    2004-09-01

    Rapid 3D NMR spectroscopy of oligosaccharides having isotopically labeled acetyl "isotags" was made possible with high resolution in the indirect dimensions using the filter diagonalization method (FDM). A pulse sequence was designed for the optimal correlation of acetyl methyl protons, methyl carbons, and carbonyl carbons. The multi-dimensional nature of the FDM, coupled with the advantages of constant-time evolution periods, resulted in marked improvements over Fourier transform (FT) and mirror-image linear prediction (MI-LP) processing methods. The three methods were directly compared using identical data sets. A highly resolved 3D spectrum was achieved with the FDM using a very short experimental time (28 min).

  1. 16 CFR 305.6 - Duty to provide labels on Web sites.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... ENERGY AND WATER USE LABELING FOR CONSUMER PRODUCTS UNDER THE ENERGY POLICY AND CONSERVATION ACT (âENERGY... manufacturer distributes in commerce after July 15, 2013, which is required by this part to bear an EnergyGuide...

  2. Nanoscale Label-free Bioprobes to Detect Intracellular Proteins in Single Living Cells

    PubMed Central

    Hong, Wooyoung; Liang, Feng; Schaak, Diane; Loncar, Marko; Quan, Qimin

    2014-01-01

    Fluorescent labeling techniques have been widely used in live cell studies; however, the labeling processes can be laborious and challenging for use in non-transfectable cells, and labels can interfere with protein functions. While label-free biosensors have been realized by nanofabrication, a method to track intracellular protein dynamics in real-time, in situ and in living cells has not been found. Here we present the first demonstration of label-free detection of intracellular p53 protein dynamics through a nanoscale surface plasmon-polariton fiber-tip-probe (FTP). PMID:25154394

  3. Person Perception and Verbal Labeling: The Development of Social Labels.

    ERIC Educational Resources Information Center

    Brooks-Gunn, Jeanne; Lewis, Michael

    This study examined the social labels which are first used by infants, social differentiation on the basis of labeling behavior, and overgeneralization of social labels. Subjects were 81 infants from 9 to 36 months of age. The 9- to 24-month-olds were shown slides of themselves, their mothers, their fathers, and unfamiliar children, babies, and…

  4. Fluorescent labeling of tetracysteine-tagged proteins in intact cells.

    PubMed

    Hoffmann, Carsten; Gaietta, Guido; Zürn, Alexander; Adams, Stephen R; Terrillon, Sonia; Ellisman, Mark H; Tsien, Roger Y; Lohse, Martin J

    2010-09-01

    In this paper, we provide a general protocol for labeling proteins with the membrane-permeant fluorogenic biarsenical dye fluorescein arsenical hairpin binder-ethanedithiol (FlAsH-EDT₂). Generation of the tetracysteine-tagged protein construct by itself is not described, as this is a protein-specific process. This method allows site-selective labeling of proteins in living cells and has been applied to a wide variety of proteins and biological problems. We provide here a generally applicable labeling procedure and discuss the problems that can occur as well as general considerations that must be taken into account when designing and implementing the procedure. The method can even be applied to proteins with expression below 1 pmol mg⁻¹ of protein, such as G protein-coupled receptors, and it can be used to study the intracellular localization of proteins as well as functional interactions in fluorescence resonance energy transfer experiments. The labeling procedure using FlAsH-EDT₂ as described takes 2-3 h, depending on the number of samples to be processed.

  5. Fluorescent labeling of tetracysteine-tagged proteins in intact cells

    PubMed Central

    Hoffmann, Carsten; Gaietta, Guido; Zürn, Alexander; Adams, Stephen R; Terrillon, Sonia; Ellisman, Mark H; Tsien, Roger Y; Lohse, Martin J

    2011-01-01

    In this paper, we provide a general protocol for labeling proteins with the membrane-permeant fluorogenic biarsenical dye fluorescein arsenical hairpin binder–ethanedithiol (FlAsH-EDT2). Generation of the tetracysteine-tagged protein construct by itself is not described, as this is a protein-specific process. This method allows site-selective labeling of proteins in living cells and has been applied to a wide variety of proteins and biological problems. We provide here a generally applicable labeling procedure and discuss the problems that can occur as well as general considerations that must be taken into account when designing and implementing the procedure. The method can even be applied to proteins with expression below 1 pmol mg−1 of protein, such as G protein–coupled receptors, and it can be used to study the intracellular localization of proteins as well as functional interactions in fluorescence resonance energy transfer experiments. The labeling procedure using FlAsH-EDT2 as described takes 2–3 h, depending on the number of samples to be processed. PMID:20885379

  6. Noncharged and Charged Monodendronised Perylene Bisimides as Highly Fluorescent Labels and their Bioconjugates.

    PubMed

    Huth, Katharina; Heek, Timm; Achazi, Katharina; Kühne, Christian; Urner, Leonhard H; Pagel, Kevin; Dernedde, Jens; Haag, Rainer

    2017-04-06

    A series of water-soluble, hydroxylated and sulphated, polyglycerol (PG) dendronised, monofunctional perylene bisimides (PBIs) were synthesised in three generations. Their photophysical properties were determined by absorption and emission spectroscopy and their suitability as potential biolabels examined by biological in vitro studies after bioconjugation. It could be shown that the photophysical properties of the PBI labels can be improved by increasing the sterical demand and ionic charge of the attached dendron. Thereby, charged labels show superior suppression of aggregation over charge neutral labels owing to electrostatic repulsion forces on the PG-dendron. The ionic charges also enabled a reduction in dendron generation while retaining the labels' outstanding fluorescence quantum yields (FQYs) up to 100 %. These core-unsubstituted perylene derivatives were successfully applied as fluorescent labels upon bioconjugation to the therapeutic antibody cetuximab. The dye-antibody conjugates showed a strongly enhanced aggregation tendency compared to the corresponding free dyes. Biological evaluation by receptor-binding, cellular uptake, and cytotoxicity studies revealed that labelling did not affect the antibody's function, which renders the noncharged and charged dendronised PBIs suitable candidates as fluorescent labels in biological imaging. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. PolSK Label Over VSB-CSRZ Payload Scheme in AOLS Network

    NASA Astrophysics Data System (ADS)

    Chen, Hongwei; Chen, Minghua; Xie, Shizhong

    2007-06-01

    A novel orthogonal modulation scheme of polarization-shift-keying label over vestigial sideband payload is proposed and experimentally demonstrated over a 43-Gb/s all-optical-label-switching transmission. With this scheme, a high extinction ratio of the label is reached, while a spectral efficiency of 0.8 b/s/Hz is achieved by weakening the imperfection of the high-speed pulse sequence in polarization modulation. Furthermore, this modulation scheme is relatively irrelevant with payload bit rate. The payload and label penalties after 80-km NZDSF fiber transmission and label erasure are 1.5 and 1 dB, respectively. The influence of filter center frequency offset is also investigated. Besides, a label rewriting method is introduced to simplify label processing in intermedia nodes. All these results show that this scheme can be a candidate technique for the next-generation optical network.

  8. Validation of an Online Food Frequency Questionnaire against Doubly Labelled Water and 24 h Dietary Recalls in Pre-School Children

    PubMed Central

    Delisle Nyström, Christine; Henriksson, Hanna; Alexandrou, Christina; Bergström, Anna; Bonn, Stephanie; Bälter, Katarina; Löf, Marie

    2017-01-01

    The development of easy-to-use and accurate methods to assess the intake of energy, foods and nutrients in pre-school children is needed. KidMeal-Q is an online food frequency questionnaire developed for the LifeGene prospective cohort study in Sweden. The aims of this study were to compare: (i) energy intake (EI) obtained using KidMeal-Q to total energy expenditure (TEE) measured via doubly labelled water and (ii) the intake of certain foods measured using KidMeal-Q to intakes acquired by means of 24 h dietary recalls in 38 children aged 5.5 years. The mean EI calculated using KidMeal-Q was statistically different (p < 0.001) from TEE (4670 ± 1430 kJ/24 h and 6070 ± 690 kJ/24 h, respectively). Significant correlations were observed for vegetables, fruit juice and candy between KidMeal-Q and 24 h dietary recalls. Only sweetened beverage consumption was significantly different in mean intake (p < 0.001), as measured by KidMeal-Q and 24 h dietary recalls. In conclusion, KidMeal-Q had a relatively short answering time and comparative validity to other food frequency questionnaires. However, its accuracy needs to be improved before it can be used in studies in pre-school children. PMID:28098765

  9. Validation of an Online Food Frequency Questionnaire against Doubly Labelled Water and 24 h Dietary Recalls in Pre-School Children.

    PubMed

    Delisle Nyström, Christine; Henriksson, Hanna; Alexandrou, Christina; Bergström, Anna; Bonn, Stephanie; Bälter, Katarina; Löf, Marie

    2017-01-13

    The development of easy-to-use and accurate methods to assess the intake of energy, foods and nutrients in pre-school children is needed. KidMeal-Q is an online food frequency questionnaire developed for the LifeGene prospective cohort study in Sweden. The aims of this study were to compare: (i) energy intake (EI) obtained using KidMeal-Q to total energy expenditure (TEE) measured via doubly labelled water and (ii) the intake of certain foods measured using KidMeal-Q to intakes acquired by means of 24 h dietary recalls in 38 children aged 5.5 years. The mean EI calculated using KidMeal-Q was statistically different ( p < 0.001) from TEE (4670 ± 1430 kJ/24 h and 6070 ± 690 kJ/24 h, respectively). Significant correlations were observed for vegetables, fruit juice and candy between KidMeal-Q and 24 h dietary recalls. Only sweetened beverage consumption was significantly different in mean intake ( p < 0.001), as measured by KidMeal-Q and 24 h dietary recalls. In conclusion, KidMeal-Q had a relatively short answering time and comparative validity to other food frequency questionnaires. However, its accuracy needs to be improved before it can be used in studies in pre-school children.

  10. A Mixtures-of-Trees Framework for Multi-Label Classification

    PubMed Central

    Hong, Charmgil; Batal, Iyad; Hauskrecht, Milos

    2015-01-01

    We propose a new probabilistic approach for multi-label classification that aims to represent the class posterior distribution P(Y|X). Our approach uses a mixture of tree-structured Bayesian networks, which can leverage the computational advantages of conditional tree-structured models and the abilities of mixtures to compensate for tree-structured restrictions. We develop algorithms for learning the model from data and for performing multi-label predictions using the learned model. Experiments on multiple datasets demonstrate that our approach outperforms several state-of-the-art multi-label classification methods. PMID:25927011

  11. Effects of muffin processing on fumonisins from 14C-labeled toxins produced in cultured corn kernels.

    PubMed

    Avantaggiato, Giuseppina; De La Campa, Regina; Miller, J David; Visconti, Angelo

    2003-10-01

    The persistence of fumonisins during cooking is known to be affected by several factors, including thermal degradation and the presence of various ingredients in corn-based food recipes that can react with the toxin. A method for the production of corn kernels containing 14C-fumonisins was developed. The corn kernels were colonized by Fusarium verticillioides MRC 826 and supplemented with 1,2-14C-sodium acetate. The specific activity of 14C-FB1 produced made the study of its fate in cornmeal muffins possible. The double-extraction acetonitrile-water-methanol/immunoaffinity column/o-phthaldialdehyde high-performance liquid chromatography (HPLC) method was used to determine FB1 levels in cornmeal muffins. Reductions in FB1 levels in muffins spiked with 14C-labeled and unlabeled FB1 (43 and 48%, respectively) were similar, indicating that the extraction method was efficient and consistent with previous reports. However, with the labeled corn kernel material, recovery levels based on the 14C counts for the eluate from an immunoaffinity column were much higher (90%). This finding indicates that some fumonisin-related compounds other than FB1 that were present in the cornmeal were recognized by the antibodies but not by the HPLC method.

  12. Enzymatically Generated CRISPR Libraries for Genome Labeling and Screening.

    PubMed

    Lane, Andrew B; Strzelecka, Magdalena; Ettinger, Andreas; Grenfell, Andrew W; Wittmann, Torsten; Heald, Rebecca

    2015-08-10

    CRISPR-based technologies have emerged as powerful tools to alter genomes and mark chromosomal loci, but an inexpensive method for generating large numbers of RNA guides for whole genome screening and labeling is lacking. Using a method that permits library construction from any source of DNA, we generated guide libraries that label repetitive loci or a single chromosomal locus in Xenopus egg extracts and show that a complex library can target the E. coli genome at high frequency. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Robust multi-atlas label propagation by deep sparse representation

    PubMed Central

    Zu, Chen; Wang, Zhengxia; Zhang, Daoqiang; Liang, Peipeng; Shi, Yonghong; Shen, Dinggang; Wu, Guorong

    2016-01-01

    to other counterpart label fusion methods. PMID:27942077

  14. Robust multi-atlas label propagation by deep sparse representation.

    PubMed

    Zu, Chen; Wang, Zhengxia; Zhang, Daoqiang; Liang, Peipeng; Shi, Yonghong; Shen, Dinggang; Wu, Guorong

    2017-03-01

    , compared to other counterpart label fusion methods.

  15. Automatic multi-label annotation of abdominal CT images using CBIR

    NASA Astrophysics Data System (ADS)

    Xue, Zhiyun; Antani, Sameer; Long, L. Rodney; Thoma, George R.

    2017-03-01

    We present a technique to annotate multiple organs shown in 2-D abdominal/pelvic CT images using CBIR. This annotation task is motivated by our research interests in visual question-answering (VQA). We aim to apply results from this effort in Open-iSM, a multimodal biomedical search engine developed by the National Library of Medicine (NLM). Understanding visual content of biomedical images is a necessary step for VQA. Though sufficient annotational information about an image may be available in related textual metadata, not all may be useful as descriptive tags, particularly for anatomy on the image. In this paper, we develop and evaluate a multi-label image annotation method using CBIR. We evaluate our method on two 2-D CT image datasets we generated from 3-D volumetric data obtained from a multi-organ segmentation challenge hosted in MICCAI 2015. Shape and spatial layout information is used to encode visual characteristics of the anatomy. We adapt a weighted voting scheme to assign multiple labels to the query image by combining the labels of the images identified as similar by the method. Key parameters that may affect the annotation performance, such as the number of images used in the label voting and the threshold for excluding labels that have low weights, are studied. The method proposes a coarse-to-fine retrieval strategy which integrates the classification with the nearest-neighbor search. Results from our evaluation (using the MICCAI CT image datasets as well as figures from Open-i) are presented.

  16. A paper-based Colorimetric Indicator Label using Natural Dye for Monitoring Shrimp Spoilage

    NASA Astrophysics Data System (ADS)

    Listyarini, A.; Sholihah, W.; Imawan, C.

    2018-05-01

    Shrimp is a type of perishable food. This study developed a simple indicator label using colorimetric method for monitoring shrimp freshness. This indicator label was made from natural dye extract of Ruellia simplex flowers which immobilized on cellulose paper by dip coating method. The indicator labels were used for examining freshness of shrimp. In this experiment, shrimp were stored in sealed bottles that have been labeled using the indicator and stored at 13 °C, 25 °C, and 40 °C for a certain range of time. Color changes of the indicator labels were observed using digital photography after shrimp storage for 0 h, 2 h, 17 h and 24 h. The color changes that occur were quantified and analyzed using the ImageJ program. The color of the indicator label when detecting the fresh shrimp was pink and after the shrimp spoilage began, the color of the label changed to purple and then became yellow when the shrimp is badly spoilage. The color change rates of label indicator increases as the shrimp storage temperature increased. These results indicate that this label indicator can be used as an indicator of the freshness of shrimps and it is not toxic and safe for food.

  17. Geomatic methods at the service of water resources modelling

    NASA Astrophysics Data System (ADS)

    Molina, José-Luis; Rodríguez-Gonzálvez, Pablo; Molina, Mª Carmen; González-Aguilera, Diego; Espejo, Fernando

    2014-02-01

    Acquisition, management and/or use of spatial information are crucial for the quality of water resources studies. In this sense, several geomatic methods arise at the service of water modelling, aiming the generation of cartographic products, especially in terms of 3D models and orthophotos. They may also perform as tools for problem solving and decision making. However, choosing the right geomatic method is still a challenge in this field. That is mostly due to the complexity of the different applications and variables involved for water resources management. This study is aimed to provide a guide to best practices in this context by tackling a deep review of geomatic methods and their suitability assessment for the following study types: Surface Hydrology, Groundwater Hydrology, Hydraulics, Agronomy, Morphodynamics and Geotechnical Processes. This assessment is driven by several decision variables grouped in two categories, classified depending on their nature as geometric or radiometric. As a result, the reader comes with the best choice/choices for the method to use, depending on the type of water resources modelling study in hand.

  18. Storable Arylpalladium(II) Reagents for Alkene Labeling in Aqueous Media

    PubMed Central

    Simmons, Rebecca L.; Yu, Robert T.; Myers, Andrew G.

    2011-01-01

    We show that arylpalladium(II) reagents linked to biotin and indocyanine dye residues can be prepared by decarboxylative palladation of appropriately substituted electron-rich benzoic acid derivatives. When prepared under the conditions described, these organometallic intermediates are tolerant of air and water, can be stored for several months in solution in dimethylsulfoxide, and permit biotin- and indocyanine dye-labeling of functionally complex olefinic substrates in water by Heck-type coupling reactions. PMID:21888420

  19. a New Multi-Spectral Threshold Normalized Difference Water Index Mst-Ndwi Water Extraction Method - a Case Study in Yanhe Watershed

    NASA Astrophysics Data System (ADS)

    Zhou, Y.; Zhao, H.; Hao, H.; Wang, C.

    2018-05-01

    Accurate remote sensing water extraction is one of the primary tasks of watershed ecological environment study. Since the Yanhe water system has typical characteristics of a small water volume and narrow river channel, which leads to the difficulty for conventional water extraction methods such as Normalized Difference Water Index (NDWI). A new Multi-Spectral Threshold segmentation of the NDWI (MST-NDWI) water extraction method is proposed to achieve the accurate water extraction in Yanhe watershed. In the MST-NDWI method, the spectral characteristics of water bodies and typical backgrounds on the Landsat/TM images have been evaluated in Yanhe watershed. The multi-spectral thresholds (TM1, TM4, TM5) based on maximum-likelihood have been utilized before NDWI water extraction to realize segmentation for a division of built-up lands and small linear rivers. With the proposed method, a water map is extracted from the Landsat/TM images in 2010 in China. An accuracy assessment is conducted to compare the proposed method with the conventional water indexes such as NDWI, Modified NDWI (MNDWI), Enhanced Water Index (EWI), and Automated Water Extraction Index (AWEI). The result shows that the MST-NDWI method generates better water extraction accuracy in Yanhe watershed and can effectively diminish the confusing background objects compared to the conventional water indexes. The MST-NDWI method integrates NDWI and Multi-Spectral Threshold segmentation algorithms, with richer valuable information and remarkable results in accurate water extraction in Yanhe watershed.

  20. 21 CFR 660.45 - Labeling.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface Antigen § 660.45 Labeling. In... capable of transmitting hepatitis and should be handled accordingly. (d) The package shall include a... test methods, and (3) warnings as to possible hazards, including hepatitis transmitted in handling the...